Sample records for guide-point modelling analysis

  1. Sonographically guided intrasheath percutaneous release of the first annular pulley for trigger digits, part 2: randomized comparative study of the economic impact of 3 surgical models.

    PubMed

    Rojo-Manaute, Jose Manuel; Capa-Grasa, Alberto; Del Cerro-Gutiérrez, Miguel; Martínez, Manuel Villanueva; Chana-Rodríguez, Francisco; Martín, Javier Vaquero

    2012-03-01

    Trigger digit surgery can be performed by an open approach using classic open surgery, by a wide-awake approach, or by sonographically guided first annular pulley release in day surgery and office-based ambulatory settings. Our goal was to perform a turnover and economic analysis of 3 surgical models. Two studies were conducted. The first was a turnover analysis of 57 patients allocated 4:4:1 into the surgical models: sonographically guided-office-based, classic open-day surgery, and wide-awake-office-based. Regression analysis for the turnover time was monitored for assessing stability (R(2) < .26). Second, on the basis of turnover times and hospital tariff revenues, we calculated the total costs, income to cost ratio, opportunity cost, true cost, true net income (primary variable), break-even points for sonographically guided fixed costs, and 1-way analysis for identifying thresholds among alternatives. Thirteen sonographically guided-office-based patients were withdrawn because of a learning curve influence. The wide-awake (n = 6) and classic (n = 26) models were compared to the last 25% of the sonographically guided group (n = 12), which showed significantly less mean turnover times, income to cost ratios 2.52 and 10.9 times larger, and true costs 75.48 and 20.92 times lower, respectively. A true net income break-even point happened after 19.78 sonographically guided-office-based procedures. Sensitivity analysis showed a threshold between wide-awake and last 25% sonographically guided true costs if the last 25% sonographically guided turnover times reached 65.23 and 27.81 minutes, respectively. However, this trial was underpowered. This trial comparing surgical models was underpowered and is inconclusive on turnover times; however, the sonographically guided-office-based approach showed shorter turnover times and better economic results with a quick recoup of the costs of sonographically assisted surgery.

  2. Application of Survival Analysis and Multistate Modeling to Understand Animal Behavior: Examples from Guide Dogs

    PubMed Central

    Asher, Lucy; Harvey, Naomi D.; Green, Martin; England, Gary C. W.

    2017-01-01

    Epidemiology is the study of patterns of health-related states or events in populations. Statistical models developed for epidemiology could be usefully applied to behavioral states or events. The aim of this study is to present the application of epidemiological statistics to understand animal behavior where discrete outcomes are of interest, using data from guide dogs to illustrate. Specifically, survival analysis and multistate modeling are applied to data on guide dogs comparing dogs that completed training and qualified as a guide dog, to those that were withdrawn from the training program. Survival analysis allows the time to (or between) a binary event(s) and the probability of the event occurring at or beyond a specified time point. Survival analysis, using a Cox proportional hazards model, was used to examine the time taken to withdraw a dog from training. Sex, breed, and other factors affected time to withdrawal. Bitches were withdrawn faster than dogs, Labradors were withdrawn faster, and Labrador × Golden Retrievers slower, than Golden Retriever × Labradors; and dogs not bred by Guide Dogs were withdrawn faster than those bred by Guide Dogs. Multistate modeling (MSM) can be used as an extension of survival analysis to incorporate more than two discrete events or states. Multistate models were used to investigate transitions between states of training to qualification as a guide dog or behavioral withdrawal, and from qualification as a guide dog to behavioral withdrawal. Sex, breed (with purebred Labradors and Golden retrievers differing from F1 crosses), and bred by Guide Dogs or not, effected movements between states. We postulate that survival analysis and MSM could be applied to a wide range of behavioral data and key examples are provided. PMID:28804710

  3. On the Electron Diffusion Region in Asymmetric Reconnection with a Guide Magnetic Field

    NASA Technical Reports Server (NTRS)

    Hesse, Michael; Liu, Yi-Hsin; Chen, Li-Jen; Bessho, Naoki; Kuznetsova, Masha; Birn, Joachim; Burch, James L.

    2016-01-01

    Particle-in-cell simulations in a 2.5-D geometry and analytical theory are employed to study the electron diffusion region in asymmetric reconnection with a guide magnetic field. The analysis presented here demonstrates that similar to the case without guide field, in-plane flow stagnation and null of the in-plane magnetic field are well separated. In addition, it is shown that the electric field at the local magnetic X point is again dominated by inertial effects, whereas it remains dominated by nongyrotropic pressure effects at the in-plane flow stagnation point. A comparison between local electron Larmor radii and the magnetic gradient scale lengths predicts that distribution should become nongyrotropic in a region enveloping both field reversal and flow stagnation points. This prediction is verified by an analysis of modeled electron distributions, which show clear evidence of mixing in the critical region.

  4. Thermal, Structural, and Optical Analysis of a Balloon-Based Imaging System

    NASA Astrophysics Data System (ADS)

    Borden, Michael; Lewis, Derek; Ochoa, Hared; Jones-Wilson, Laura; Susca, Sara; Porter, Michael; Massey, Richard; Clark, Paul; Netterfield, Barth

    2017-03-01

    The Subarcsecond Telescope And BaLloon Experiment, STABLE, is the fine stage of a guidance system for a high-altitude ballooning platform designed to demonstrate subarcsecond pointing stability over one minute using relatively dim guide stars in the visible spectrum. The STABLE system uses an attitude rate sensor and the motion of the guide star on a detector to control a Fast Steering Mirror to stabilize the image. The characteristics of the thermal-optical-mechanical elements in the system directly affect the quality of the point-spread function of the guide star on the detector, so a series of thermal, structural, and optical models were built to simulate system performance and ultimately inform the final pointing stability predictions. This paper describes the modeling techniques employed in each of these subsystems. The results from those models are discussed in detail, highlighting the development of the worst-case cold and hot cases, the optical metrics generated from the finite element model, and the expected STABLE residual wavefront error and decenter. Finally, the paper concludes with the predicted sensitivities in the STABLE system, which show that thermal deadbanding, structural pre-loading, and self-deflection under different loading conditions, and the speed of individual optical elements were particularly important to the resulting STABLE optical performance.

  5. Generalized linear models and point count data: statistical considerations for the design and analysis of monitoring studies

    Treesearch

    Nathaniel E. Seavy; Suhel Quader; John D. Alexander; C. John Ralph

    2005-01-01

    The success of avian monitoring programs to effectively guide management decisions requires that studies be efficiently designed and data be properly analyzed. A complicating factor is that point count surveys often generate data with non-normal distributional properties. In this paper we review methods of dealing with deviations from normal assumptions, and we focus...

  6. Improved Point Analysis Model (IPAM) (Users Guide)

    DTIC Science & Technology

    1991-02-01

    Descriptions 7 Stratus fractus of bad weather* or Cumulus fractus of bad weather, or both ( pannus ), usually below Altostratus or Nimbostratus. 8...Cumulonimbus without anvil or fibrous upper part, Cumulus, Stratocumulus, Stratus or pannus . / Stratocumulus, Stratus, Cumulus and Cumulonimbus invisible owing

  7. [Powdered infant formulae preparation guide for hospitals based on Hazard Analysis and Critical Control Points (HACCP) principles].

    PubMed

    Vargas-Leguás, H; Rodríguez Garrido, V; Lorite Cuenca, R; Pérez-Portabella, C; Redecillas Ferreiro, S; Campins Martí, M

    2009-06-01

    This guide for the preparation of powdered infant formulae in hospital environments is a collaborative work between several hospital services and is based on national and European regulations, international experts meetings and the recommendations of scientific societies. This guide also uses the Hazard Analysis and Critical Control Point principles proposed by Codex Alimentarius and emphasises effective verifying measures, microbiological controls of the process and the corrective actions when monitoring indicates that a critical control point is not under control. It is a dynamic guide and specifies the evaluation procedures that allow it to be constantly adapted.

  8. Defect induced guided waves mode conversion

    NASA Astrophysics Data System (ADS)

    Wandowski, Tomasz; Kudela, Pawel; Malinowski, Pawel; Ostachowicz, Wieslaw

    2016-04-01

    This paper deals with analysis of guided waves mode conversion phenomenon in fiber reinforced composite materials. Mode conversion phenomenon may take place when propagating elastic guided waves interact with discontinuities in the composite waveguide. The examples of such discontinuities are sudden thickness change or delamination between layers in composite material. In this paper, analysis of mode conversion phenomenon is based on full wave-field signals. In the full wave-field approach signals representing propagation of elastic waves are gathered from dense mesh of points that span over investigated area of composite part. This allow to animate the guided wave propagation. The reported analysis is based on signals resulting from numerical calculations and experimental measurements. In both cases defect in the form of delamination is considered. In the case of numerical research, Spectral Element Method (SEM) is utilized, in which a mesh is composed of 3D elements. Numerical model includes also piezoelectric transducer. Full wave-field experimental measurements are conducted by using piezoelectric transducer for guided wave excitation and Scanning Laser Doppler Vibrometer (SLDV) for sensing.

  9. Graph-based geometric-iconic guide-wire tracking.

    PubMed

    Honnorat, Nicolas; Vaillant, Régis; Paragios, Nikos

    2011-01-01

    In this paper we introduce a novel hybrid graph-based approach for Guide-wire tracking. The image support is captured by steerable filters and improved through tensor voting. Then, a graphical model is considered that represents guide-wire extraction/tracking through a B-spline control-point model. Points with strong geometric interest (landmarks) are automatically determined and anchored to such a representation. Tracking is then performed through discrete MRFs that optimize the spatio-temporal positions of the control points while establishing landmark temporal correspondences. Promising results demonstrate the potentials of our method.

  10. Social Phenomenological Analysis as a Research Method in Art Education: Developing an Empirical Model for Understanding Gallery Talks

    ERIC Educational Resources Information Center

    Hofmann, Fabian

    2016-01-01

    Social phenomenological analysis is presented as a research method to study gallery talks or guided tours in art museums. The research method is based on the philosophical considerations of Edmund Husserl and sociological/social science concepts put forward by Max Weber and Alfred Schuetz. Its starting point is the everyday lifeworld; the…

  11. A bifurcation study to guide the design of a landing gear with a combined uplock/downlock mechanism.

    PubMed

    Knowles, James A C; Lowenberg, Mark H; Neild, Simon A; Krauskopf, Bernd

    2014-12-08

    This paper discusses the insights that a bifurcation analysis can provide when designing mechanisms. A model, in the form of a set of coupled steady-state equations, can be derived to describe the mechanism. Solutions to this model can be traced through the mechanism's state versus parameter space via numerical continuation, under the simultaneous variation of one or more parameters. With this approach, crucial features in the response surface, such as bifurcation points, can be identified. By numerically continuing these points in the appropriate parameter space, the resulting bifurcation diagram can be used to guide parameter selection and optimization. In this paper, we demonstrate the potential of this technique by considering an aircraft nose landing gear, with a novel locking strategy that uses a combined uplock/downlock mechanism. The landing gear is locked when in the retracted or deployed states. Transitions between these locked states and the unlocked state (where the landing gear is a mechanism) are shown to depend upon the positions of two fold point bifurcations. By performing a two-parameter continuation, the critical points are traced to identify operational boundaries. Following the variation of the fold points through parameter space, a minimum spring stiffness is identified that enables the landing gear to be locked in the retracted state. The bifurcation analysis also shows that the unlocking of a retracted landing gear should use an unlock force measure, rather than a position indicator, to de-couple the effects of the retraction and locking actuators. Overall, the study demonstrates that bifurcation analysis can enhance the understanding of the influence of design choices over a wide operating range where nonlinearity is significant.

  12. A bifurcation study to guide the design of a landing gear with a combined uplock/downlock mechanism

    PubMed Central

    Knowles, James A. C.; Lowenberg, Mark H.; Neild, Simon A.; Krauskopf, Bernd

    2014-01-01

    This paper discusses the insights that a bifurcation analysis can provide when designing mechanisms. A model, in the form of a set of coupled steady-state equations, can be derived to describe the mechanism. Solutions to this model can be traced through the mechanism's state versus parameter space via numerical continuation, under the simultaneous variation of one or more parameters. With this approach, crucial features in the response surface, such as bifurcation points, can be identified. By numerically continuing these points in the appropriate parameter space, the resulting bifurcation diagram can be used to guide parameter selection and optimization. In this paper, we demonstrate the potential of this technique by considering an aircraft nose landing gear, with a novel locking strategy that uses a combined uplock/downlock mechanism. The landing gear is locked when in the retracted or deployed states. Transitions between these locked states and the unlocked state (where the landing gear is a mechanism) are shown to depend upon the positions of two fold point bifurcations. By performing a two-parameter continuation, the critical points are traced to identify operational boundaries. Following the variation of the fold points through parameter space, a minimum spring stiffness is identified that enables the landing gear to be locked in the retracted state. The bifurcation analysis also shows that the unlocking of a retracted landing gear should use an unlock force measure, rather than a position indicator, to de-couple the effects of the retraction and locking actuators. Overall, the study demonstrates that bifurcation analysis can enhance the understanding of the influence of design choices over a wide operating range where nonlinearity is significant. PMID:25484601

  13. Accuracy comparison of guided surgery for dental implants according to the tissue of support: a systematic review and meta-analysis.

    PubMed

    Raico Gallardo, Yolanda Natali; da Silva-Olivio, Isabela Rodrigues Teixeira; Mukai, Eduardo; Morimoto, Susana; Sesma, Newton; Cordaro, Luca

    2017-05-01

    To systematically assess the current dental literature comparing the accuracy of computer-aided implant surgery when using different supporting tissues (tooth, mucosa, or bone). Two reviewers searched PubMed (1972 to January 2015) and the Cochrane Central Register of Controlled Trials (Central) (2002 to January 2015). For the assessment of accuracy, studies were included with the following outcome measures: (i) angle deviation, (ii) deviation at the entry point, and (iii) deviation at the apex. Eight clinical studies from the 1602 articles initially identified met the inclusion criteria for the qualitative analysis. Four studies (n = 599 implants) were evaluated using meta-analysis. The bone-supported guides showed a statistically significant greater deviation in angle (P < 0.001), entry point (P = 0.01), and the apex (P = 0.001) when compared to the tooth-supported guides. Conversely, when only retrospective studies were analyzed, not significant differences are revealed in the deviation of the entry point and apex. The mucosa-supported guides indicated a statistically significant greater reduction in angle deviation (P = 0.02), deviation at the entry point (P = 0.002), and deviation at the apex (P = 0.04) when compared to the bone-supported guides. Between the mucosa- and tooth-supported guides, there were no statistically significant differences for any of the outcome measures. It can be concluded that the tissue of the guide support influences the accuracy of computer-aided implant surgery. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. High‐resolution trench photomosaics from image‐based modeling: Workflow and error analysis

    USGS Publications Warehouse

    Reitman, Nadine G.; Bennett, Scott E. K.; Gold, Ryan D.; Briggs, Richard; Duross, Christopher

    2015-01-01

    Photomosaics are commonly used to construct maps of paleoseismic trench exposures, but the conventional process of manually using image‐editing software is time consuming and produces undesirable artifacts and distortions. Herein, we document and evaluate the application of image‐based modeling (IBM) for creating photomosaics and 3D models of paleoseismic trench exposures, illustrated with a case‐study trench across the Wasatch fault in Alpine, Utah. Our results include a structure‐from‐motion workflow for the semiautomated creation of seamless, high‐resolution photomosaics designed for rapid implementation in a field setting. Compared with conventional manual methods, the IBM photomosaic method provides a more accurate, continuous, and detailed record of paleoseismic trench exposures in approximately half the processing time and 15%–20% of the user input time. Our error analysis quantifies the effect of the number and spatial distribution of control points on model accuracy. For this case study, an ∼87  m2 exposure of a benched trench photographed at viewing distances of 1.5–7 m yields a model with <2  cm root mean square error (rmse) with as few as six control points. Rmse decreases as more control points are implemented, but the gains in accuracy are minimal beyond 12 control points. Spreading control points throughout the target area helps to minimize error. We propose that 3D digital models and corresponding photomosaics should be standard practice in paleoseismic exposure archiving. The error analysis serves as a guide for future investigations that seek balance between speed and accuracy during photomosaic and 3D model construction.

  15. Programmer/Analyst Guide for the Army Unit Resiliency Analysis (AURA) computer Simulation Model. Volume 1. AURA Methodology

    DTIC Science & Technology

    1990-10-01

    involving a heavy artillery barrage, the impact point output alone could consume upwards of 10,000 pages of computer paper. For this reason, AURA provides...but pervasive factor: the asset allocation model must be compatible with the mathematical behavior of the input data. Thus, for example, if assets are...described as expendable during repair or decontamination activities, it must have HOMELINKS which appear in the consuming repair SUBCHAINs

  16. Analysis of Free Modeling Predictions by RBO Aleph in CASP11

    PubMed Central

    Mabrouk, Mahmoud; Werner, Tim; Schneider, Michael; Putz, Ines; Brock, Oliver

    2015-01-01

    The CASP experiment is a biannual benchmark for assessing protein structure prediction methods. In CASP11, RBO Aleph ranked as one of the top-performing automated servers in the free modeling category. This category consists of targets for which structural templates are not easily retrievable. We analyze the performance of RBO Aleph and show that its success in CASP was a result of its ab initio structure prediction protocol. A detailed analysis of this protocol demonstrates that two components unique to our method greatly contributed to prediction quality: residue–residue contact prediction by EPC-map and contact–guided conformational space search by model-based search (MBS). Interestingly, our analysis also points to a possible fundamental problem in evaluating the performance of protein structure prediction methods: Improvements in components of the method do not necessarily lead to improvements of the entire method. This points to the fact that these components interact in ways that are poorly understood. This problem, if indeed true, represents a significant obstacle to community-wide progress. PMID:26492194

  17. Numerical investigation on performance and sediment erosion of Francis runner with different guide vane profiles

    NASA Astrophysics Data System (ADS)

    Lama, R.; Dahal, D. R.; Gautam, S.; Acharya, N.; Neopane, H.; Thapa, B. S.

    2018-06-01

    Francis turbine are ideal turbines for Himalayan and Andes region where both low and high-altitude mountains are located. Turbines operating in such regions face operational and maintenance problems due to the sediment erosion. In order to reduce the erosion effects on these components the design of components for higher sediment handling is essence. This paper presents performance analysis of Francis runner and prediction of sediment erosion on the runner blades for different operating conditions with different guide vane profiles. The simulations were carried out for 11 guide vane opening angles using Tabakoff erosion model. At full load and best efficiency point the erosion was localized at pressure side of runner blades outlet due to higher relative velocity. On the other hand, at part load condition, erosion was observed at suction side of the blades. Application of asymmetric guide vane profile NACA 4412 showed higher efficiency for all operating conditions with minimum erosion on runner blades in compare to symmetric guide vane profile NACA 0012.

  18. Applications of Panoramic Images: from 720° Panorama to Interior 3d Models of Augmented Reality

    NASA Astrophysics Data System (ADS)

    Lee, I.-C.; Tsai, F.

    2015-05-01

    A series of panoramic images are usually used to generate a 720° panorama image. Although panoramic images are typically used for establishing tour guiding systems, in this research, we demonstrate the potential of using panoramic images acquired from multiple sites to create not only 720° panorama, but also three-dimensional (3D) point clouds and 3D indoor models. Since 3D modeling is one of the goals of this research, the location of the panoramic sites needed to be carefully planned in order to maintain a robust result for close-range photogrammetry. After the images are acquired, panoramic images are processed into 720° panoramas, and these panoramas which can be used directly as panorama guiding systems or other applications. In addition to these straightforward applications, interior orientation parameters can also be estimated while generating 720° panorama. These parameters are focal length, principle point, and lens radial distortion. The panoramic images can then be processed with closerange photogrammetry procedures to extract the exterior orientation parameters and generate 3D point clouds. In this research, VisaulSFM, a structure from motion software is used to estimate the exterior orientation, and CMVS toolkit is used to generate 3D point clouds. Next, the 3D point clouds are used as references to create building interior models. In this research, Trimble Sketchup was used to build the model, and the 3D point cloud was added to the determining of locations of building objects using plane finding procedure. In the texturing process, the panorama images are used as the data source for creating model textures. This 3D indoor model was used as an Augmented Reality model replacing a guide map or a floor plan commonly used in an on-line touring guide system. The 3D indoor model generating procedure has been utilized in two research projects: a cultural heritage site at Kinmen, and Taipei Main Station pedestrian zone guidance and navigation system. The results presented in this paper demonstrate the potential of using panoramic images to generate 3D point clouds and 3D models. However, it is currently a manual and labor-intensive process. A research is being carried out to Increase the degree of automation of these procedures.

  19. Consumer Control Points: Creating a Visual Food Safety Education Model for Consumers.

    ERIC Educational Resources Information Center

    Schiffman, Carole B.

    Consumer education has always been a primary consideration in the prevention of food-borne illness. Using nutrition education and the new food guide as a model, this paper develops suggestions for a framework of microbiological food safety principles and a compatible visual model for communicating key concepts. Historically, visual food guides in…

  20. Volumetric Trends Associated with MR-guided Stereotactic Laser Amygdalohippocampectomy in Mesial Temporal Lobe Epilepsy

    PubMed Central

    Patel, Nitesh V; Sundararajan, Sri; Keller, Irwin; Danish, Shabbar

    2018-01-01

    Objective: Magnetic resonance (MR)-guided stereotactic laser amygdalohippocampectomy is a minimally invasive procedure for the treatment of refractory epilepsy in patients with mesial temporal sclerosis. Limited data exist on post-ablation volumetric trends associated with the procedure. Methods: 10 patients with mesial temporal sclerosis underwent MR-guided stereotactic laser amygdalohippocampectomy. Three independent raters computed ablation volumes at the following time points: pre-ablation (PreA), immediate post-ablation (IPA), 24 hours post-ablation (24PA), first follow-up post-ablation (FPA), and greater than three months follow-up post-ablation (>3MPA), using OsiriX DICOM Viewer (Pixmeo, Bernex, Switzerland). Statistical trends in post-ablation volumes were determined for the time points. Results: MR-guided stereotactic laser amygdalohippocampectomy produces a rapid rise and distinct peak in post-ablation volume immediately following the procedure. IPA volumes are significantly higher than all other time points. Comparing individual time points within each raters dataset (intra-rater), a significant difference was seen between the IPA time point and all others. There was no statistical difference between the 24PA, FPA, and >3MPA time points. A correlation analysis demonstrated the strongest correlations at the 24PA (r=0.97), FPA (r=0.95), and 3MPA time points (r=0.99), with a weaker correlation at IPA (r=0.92). Conclusion: MR-guided stereotactic laser amygdalohippocampectomy produces a maximal increase in post-ablation volume immediately following the procedure, which decreases and stabilizes at 24 hours post-procedure and beyond three months follow-up. Based on the correlation analysis, the lower inter-rater reliability at the IPA time point suggests it may be less accurate to assess volume at this time point. We recommend post-ablation volume assessments be made at least 24 hours post-selective ablation of the amygdalohippocampal complex (SLAH).

  1. Chiral behaviour of the wave functions for three wave guides in the vicinity of an exceptional point of third order

    NASA Astrophysics Data System (ADS)

    Heiss, Walter Dieter; Wunner, Günter

    2017-12-01

    A matrix model that has been used to describe essential features of a parity-time symmetric set-up of three coupled wave guides is investigated. The emphasis of the study lies on the occurrence of an exceptional point of third order. It is demonstrated that the eigenfunctions in close vicinity of the exceptional point have a distinctive chiral behaviour. Using data describing realistic situations it is argued that such chiral behaviour can be tested experimentally.

  2. Program Model Checking: A Practitioner's Guide

    NASA Technical Reports Server (NTRS)

    Pressburger, Thomas T.; Mansouri-Samani, Masoud; Mehlitz, Peter C.; Pasareanu, Corina S.; Markosian, Lawrence Z.; Penix, John J.; Brat, Guillaume P.; Visser, Willem C.

    2008-01-01

    Program model checking is a verification technology that uses state-space exploration to evaluate large numbers of potential program executions. Program model checking provides improved coverage over testing by systematically evaluating all possible test inputs and all possible interleavings of threads in a multithreaded system. Model-checking algorithms use several classes of optimizations to reduce the time and memory requirements for analysis, as well as heuristics for meaningful analysis of partial areas of the state space Our goal in this guidebook is to assemble, distill, and demonstrate emerging best practices for applying program model checking. We offer it as a starting point and introduction for those who want to apply model checking to software verification and validation. The guidebook will not discuss any specific tool in great detail, but we provide references for specific tools.

  3. Capturing tumor complexity in vitro: Comparative analysis of 2D and 3D tumor models for drug discovery.

    PubMed

    Stock, Kristin; Estrada, Marta F; Vidic, Suzana; Gjerde, Kjersti; Rudisch, Albin; Santo, Vítor E; Barbier, Michaël; Blom, Sami; Arundkar, Sharath C; Selvam, Irwin; Osswald, Annika; Stein, Yan; Gruenewald, Sylvia; Brito, Catarina; van Weerden, Wytske; Rotter, Varda; Boghaert, Erwin; Oren, Moshe; Sommergruber, Wolfgang; Chong, Yolanda; de Hoogt, Ronald; Graeser, Ralph

    2016-07-01

    Two-dimensional (2D) cell cultures growing on plastic do not recapitulate the three dimensional (3D) architecture and complexity of human tumors. More representative models are required for drug discovery and validation. Here, 2D culture and 3D mono- and stromal co-culture models of increasing complexity have been established and cross-comparisons made using three standard cell carcinoma lines: MCF7, LNCaP, NCI-H1437. Fluorescence-based growth curves, 3D image analysis, immunohistochemistry and treatment responses showed that end points differed according to cell type, stromal co-culture and culture format. The adaptable methodologies described here should guide the choice of appropriate simple and complex in vitro models.

  4. Capturing tumor complexity in vitro: Comparative analysis of 2D and 3D tumor models for drug discovery

    PubMed Central

    Stock, Kristin; Estrada, Marta F.; Vidic, Suzana; Gjerde, Kjersti; Rudisch, Albin; Santo, Vítor E.; Barbier, Michaël; Blom, Sami; Arundkar, Sharath C.; Selvam, Irwin; Osswald, Annika; Stein, Yan; Gruenewald, Sylvia; Brito, Catarina; van Weerden, Wytske; Rotter, Varda; Boghaert, Erwin; Oren, Moshe; Sommergruber, Wolfgang; Chong, Yolanda; de Hoogt, Ronald; Graeser, Ralph

    2016-01-01

    Two-dimensional (2D) cell cultures growing on plastic do not recapitulate the three dimensional (3D) architecture and complexity of human tumors. More representative models are required for drug discovery and validation. Here, 2D culture and 3D mono- and stromal co-culture models of increasing complexity have been established and cross-comparisons made using three standard cell carcinoma lines: MCF7, LNCaP, NCI-H1437. Fluorescence-based growth curves, 3D image analysis, immunohistochemistry and treatment responses showed that end points differed according to cell type, stromal co-culture and culture format. The adaptable methodologies described here should guide the choice of appropriate simple and complex in vitro models. PMID:27364600

  5. BIOMECHANICAL ANALYSIS OF THE STRESSES GENERATED BY DIFFERENT DISOCCLUSION PATTERNS IN AN IMPLANT-SUPPORTED MANDIBULAR COMPLETE DENTURE

    PubMed Central

    Greco, Gustavo Diniz; Jansen, Wellington Corrêa; Landre, Janis; Seraidarian, Paulo Isaías

    2009-01-01

    Objectives: This study evaluated by three-dimensional finite element analysis the tensions generated by different disocclusion patterns (canine guide and bilateral balanced occlusion) in an implant-supported mandibular complete denture. Material and Methods: A three-dimensional model of implant-supported mandibular complete denture was fabricated according to the Brånemark protocol. A 5-element 3.75 x 13-mm screw-shape dental implant system was modeled for this study. The implants were located in the intermental foramen region with 3-mm-high prosthetic components joined by a nickel-chromium framework with 12-mm bilateral cantilever covered by acrylic resin and 12 acrylic denture teeth. SolidWorks® software was used before and after processing the simulations. The mechanical properties of the components were inserted in the model and a 15 N load was established in fixed points, in each one of the simulations. Data were collected in the entire nickel-chromium framework. The results were displayed three-dimensionally as color graphic scales. Results: The canine guide generated greater tensions in the region of the first implant, while the bilateral balanced occlusion generated great tensions in the entire metallic framework. The maximum tension found in the simulation of the bilateral balanced occlusion was 3.22 fold higher than the one found in the simulation of the disocclusion in canine guide. Conclusion: The pattern of disocclusion in canine guide is the ideal for implant-supported mandibular complete denture. PMID:19936535

  6. Biomechanical analysis of the stresses generated by different disocclusion patterns in an implant-supported mandibular complete denture.

    PubMed

    Greco, Gustavo Diniz; Jansen, Wellington Corrêa; Landre Junior, Janis; Seraidarian, Paulo Isaías

    2009-01-01

    This study evaluated by three-dimensional finite element analysis the tensions generated by different disocclusion patterns (canine guide and bilateral balanced occlusion) in an implant-supported mandibular complete denture. A three-dimensional model of implant-supported mandibular complete denture was fabricated according to the Brånemark protocol. A 5-element 3.75 x 13-mm screw-shape dental implant system was modeled for this study. The implants were located in the inter-mental foramen region with 3-mm-high prosthetic components joined by a nickel-chromium framework with 12-mm bilateral cantilever covered by acrylic resin and 12 acrylic denture teeth. SolidWorks software was used before and after processing the simulations. The mechanical properties of the components were inserted in the model and a 15 N load was established in fixed points, in each one of the simulations. Data were collected in the entire nickel-chromium framework. The results were displayed three-dimensionally as color graphic scales. The canine guide generated greater tensions in the region of the first implant, while the bilateral balanced occlusion generated great tensions in the entire metallic framework. The maximum tension found in the simulation of the bilateral balanced occlusion was 3.22 fold higher than the one found in the simulation of the disocclusion in canine guide. The pattern of disocclusion in canine guide is the ideal for implant-supported mandibular complete denture.

  7. Vectorial model for guided-mode resonance gratings

    NASA Astrophysics Data System (ADS)

    Fehrembach, A.-L.; Gralak, B.; Sentenac, A.

    2018-04-01

    We propose a self-consistent vectorial method, based on a Green's function technique, to describe the resonances that appear in guided-mode resonance gratings. The model provides intuitive expressions of the reflectivity and transmittivity matrices of the structure, involving coupling integrals between the modes of a planar reference structure and radiative modes. When one mode is excited, the diffracted field for a suitable polarization can be written as the sum of a resonant and a nonresonant term, thus extending the intuitive approach used to explain the Fano shape of the resonance in scalar configurations. When two modes are excited, we derive a physical analysis in a configuration which requires a vectorial approach. We provide numerical validations of our model. From a technical point of view, we show how the Green's tensor of our planar reference structure can be expressed as two scalar Green's functions, and how to deal with the singularity of the Green's tensor.

  8. Analysis of longitudinal data from animals where some data are missing in SPSS

    PubMed Central

    Duricki, DA; Soleman, S; Moon, LDF

    2017-01-01

    Testing of therapies for disease or injury often involves analysis of longitudinal data from animals. Modern analytical methods have advantages over conventional methods (particularly where some data are missing) yet are not used widely by pre-clinical researchers. We provide here an easy to use protocol for analysing longitudinal data from animals and present a click-by-click guide for performing suitable analyses using the statistical package SPSS. We guide readers through analysis of a real-life data set obtained when testing a therapy for brain injury (stroke) in elderly rats. We show that repeated measures analysis of covariance failed to detect a treatment effect when a few data points were missing (due to animal drop-out) whereas analysis using an alternative method detected a beneficial effect of treatment; specifically, we demonstrate the superiority of linear models (with various covariance structures) analysed using Restricted Maximum Likelihood estimation (to include all available data). This protocol takes two hours to follow. PMID:27196723

  9. Allogeneic transplantation provides durable remission in a subset of DLBCL patients relapsing after autologous transplantation.

    PubMed

    Fenske, Timothy S; Ahn, Kwang W; Graff, Tara M; DiGilio, Alyssa; Bashir, Qaiser; Kamble, Rammurti T; Ayala, Ernesto; Bacher, Ulrike; Brammer, Jonathan E; Cairo, Mitchell; Chen, Andy; Chen, Yi-Bin; Chhabra, Saurabh; D'Souza, Anita; Farooq, Umar; Freytes, Cesar; Ganguly, Siddhartha; Hertzberg, Mark; Inwards, David; Jaglowski, Samantha; Kharfan-Dabaja, Mohamed A; Lazarus, Hillard M; Nathan, Sunita; Pawarode, Attaphol; Perales, Miguel-Angel; Reddy, Nishitha; Seo, Sachiko; Sureda, Anna; Smith, Sonali M; Hamadani, Mehdi

    2016-07-01

    For diffuse large B-cell lymphoma (DLBCL) patients progressing after autologous haematopoietic cell transplantation (autoHCT), allogeneic HCT (alloHCT) is often considered, although limited information is available to guide patient selection. Using the Center for International Blood and Marrow Transplant Research (CIBMTR) database, we identified 503 patients who underwent alloHCT after disease progression/relapse following a prior autoHCT. The 3-year probabilities of non-relapse mortality, progression/relapse, progression-free survival (PFS) and overall survival (OS) were 30, 38, 31 and 37% respectively. Factors associated with inferior PFS on multivariate analysis included Karnofsky performance status (KPS) <80, chemoresistance, autoHCT to alloHCT interval <1-year and myeloablative conditioning. Factors associated with worse OS on multivariate analysis included KPS<80, chemoresistance and myeloablative conditioning. Three adverse prognostic factors were used to construct a prognostic model for PFS, including KPS<80 (4 points), autoHCT to alloHCT interval <1-year (2 points) and chemoresistant disease at alloHCT (5 points). This CIBMTR prognostic model classified patients into four groups: low-risk (0 points), intermediate-risk (2-5 points), high-risk (6-9 points) or very high-risk (11 points), predicting 3-year PFS of 40, 32, 11 and 6%, respectively, with 3-year OS probabilities of 43, 39, 19 and 11% respectively. In conclusion, the CIBMTR prognostic model identifies a subgroup of DLBCL patients experiencing long-term survival with alloHCT after a failed prior autoHCT. © 2016 John Wiley & Sons Ltd.

  10. A statistical motion model based on biomechanical simulations for data fusion during image-guided prostate interventions.

    PubMed

    Hu, Yipeng; Morgan, Dominic; Ahmed, Hashim Uddin; Pendsé, Doug; Sahu, Mahua; Allen, Clare; Emberton, Mark; Hawkes, David; Barratt, Dean

    2008-01-01

    A method is described for generating a patient-specific, statistical motion model (SMM) of the prostate gland. Finite element analysis (FEA) is used to simulate the motion of the gland using an ultrasound-based 3D FE model over a range of plausible boundary conditions and soft-tissue properties. By applying principal component analysis to the displacements of the FE mesh node points inside the gland, the simulated deformations are then used as training data to construct the SMM. The SMM is used to both predict the displacement field over the whole gland and constrain a deformable surface registration algorithm, given only a small number of target points on the surface of the deformed gland. Using 3D transrectal ultrasound images of the prostates of five patients, acquired before and after imposing a physical deformation, to evaluate the accuracy of predicted landmark displacements, the mean target registration error was found to be less than 1.9 mm.

  11. Analysis of free modeling predictions by RBO aleph in CASP11.

    PubMed

    Mabrouk, Mahmoud; Werner, Tim; Schneider, Michael; Putz, Ines; Brock, Oliver

    2016-09-01

    The CASP experiment is a biannual benchmark for assessing protein structure prediction methods. In CASP11, RBO Aleph ranked as one of the top-performing automated servers in the free modeling category. This category consists of targets for which structural templates are not easily retrievable. We analyze the performance of RBO Aleph and show that its success in CASP was a result of its ab initio structure prediction protocol. A detailed analysis of this protocol demonstrates that two components unique to our method greatly contributed to prediction quality: residue-residue contact prediction by EPC-map and contact-guided conformational space search by model-based search (MBS). Interestingly, our analysis also points to a possible fundamental problem in evaluating the performance of protein structure prediction methods: Improvements in components of the method do not necessarily lead to improvements of the entire method. This points to the fact that these components interact in ways that are poorly understood. This problem, if indeed true, represents a significant obstacle to community-wide progress. Proteins 2016; 84(Suppl 1):87-104. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  12. Language Needs Analysis from a Perspective of International Professional Mobility: The Case of French Mountain Guides

    ERIC Educational Resources Information Center

    Wozniak, Severine

    2010-01-01

    This paper gives a detailed account of an analysis carried out at the French National Skiing and Mountaineering School from August 2008 to June 2009 to assess the language needs of French mountain guides. A targeted literature review highlighted two main points to be taken into account in the design of this language needs analysis: target…

  13. Using Uncertainty Quantification to Guide Development and Improvements of a Regional-Scale Model of the Coastal Lowlands Aquifer System Spanning Texas, Louisiana, Mississippi, Alabama and Florida

    NASA Astrophysics Data System (ADS)

    Foster, L. K.; Clark, B. R.; Duncan, L. L.; Tebo, D. T.; White, J.

    2017-12-01

    Several historical groundwater models exist within the Coastal Lowlands Aquifer System (CLAS), which spans the Gulf Coastal Plain in Texas, Louisiana, Mississippi, Alabama, and Florida. The largest of these models, called the Gulf Coast Regional Aquifer System Analysis (RASA) model, has been brought into a new framework using the Newton formulation for MODFLOW-2005 (MODFLOW-NWT) and serves as the starting point of a new investigation underway by the U.S. Geological Survey to improve understanding of the CLAS and provide predictions of future groundwater availability within an uncertainty quantification (UQ) framework. The use of an UQ framework will not only provide estimates of water-level observation worth, hydraulic parameter uncertainty, boundary-condition uncertainty, and uncertainty of future potential predictions, but it will also guide the model development process. Traditionally, model development proceeds from dataset construction to the process of deterministic history matching, followed by deterministic predictions using the model. This investigation will combine the use of UQ with existing historical models of the study area to assess in a quantitative framework the effect model package and property improvements have on the ability to represent past-system states, as well as the effect on the model's ability to make certain predictions of water levels, water budgets, and base-flow estimates. Estimates of hydraulic property information and boundary conditions from the existing models and literature, forming the prior, will be used to make initial estimates of model forecasts and their corresponding uncertainty, along with an uncalibrated groundwater model run within an unconstrained Monte Carlo analysis. First-Order Second-Moment (FOSM) analysis will also be used to investigate parameter and predictive uncertainty, and guide next steps in model development prior to rigorous history matching by using PEST++ parameter estimation code.

  14. Evaluation and "PACE": A Study of Procedures and Effectiveness of Evaluation Sections in Approved PACE Project, with Recommendations for Improvement.

    ERIC Educational Resources Information Center

    Miller, Richard I.

    This report is based upon an analysis of the evaluation procedures outlined in 21 funded Title III proposals. The proposals were analyzed from a number of points of view. (1) Using the Stufflabeam model as a guide, they were examined to determine what, if any, provisions had been made for each of the four classes of evaluation: context, input,…

  15. Fluid-structure coupling in the guide vanes cascade of a pump-turbine scale model

    NASA Astrophysics Data System (ADS)

    Roth, S.; Hasmatuchi, V.; Botero, F.; Farhat, M.; Avellan, F.

    2010-08-01

    The present study concerns fluid-structure coupling phenomena occurring in a guide vane cascade of a pump-turbine scale model placed in the EPFL PF3 test rig. An advanced instrument set is used to monitor both vibrating structures and the surrounding flow. The paper highlights the interaction between vibrating guide vanes and the flow behavior. The pressure fluctuations in the stay vanes region are found to be strongly influenced by the amplitude of the vibrating guide vanes. Moreover, the flow induces different hydrodynamic damping on the vibrating guide vanes depending on the operating point of the pump-turbine.

  16. Analysis of longitudinal data from animals with missing values using SPSS.

    PubMed

    Duricki, Denise A; Soleman, Sara; Moon, Lawrence D F

    2016-06-01

    Testing of therapies for disease or injury often involves the analysis of longitudinal data from animals. Modern analytical methods have advantages over conventional methods (particularly when some data are missing), yet they are not used widely by preclinical researchers. Here we provide an easy-to-use protocol for the analysis of longitudinal data from animals, and we present a click-by-click guide for performing suitable analyses using the statistical package IBM SPSS Statistics software (SPSS). We guide readers through the analysis of a real-life data set obtained when testing a therapy for brain injury (stroke) in elderly rats. If a few data points are missing, as in this example data set (for example, because of animal dropout), repeated-measures analysis of covariance may fail to detect a treatment effect. An alternative analysis method, such as the use of linear models (with various covariance structures), and analysis using restricted maximum likelihood estimation (to include all available data) can be used to better detect treatment effects. This protocol takes 2 h to carry out.

  17. Modeling of Highly Instrumented Honeywell Turbofan Engine Tested with Ice Crystal Ingestion in the NASA Propulsion System Laboratory

    NASA Technical Reports Server (NTRS)

    Veres, Joseph P.; Jorgenson, Philip C. E.; Jones, Scott M.

    2016-01-01

    The Propulsion Systems Laboratory (PSL), an altitude test facility at NASA Glenn Research Center, has been used to test a highly instrumented turbine engine at simulated altitude operating conditions. This is a continuation of the PSL testing that successfully duplicated the icing events that were experienced in a previous engine (serial LF01) during flight through ice crystal clouds, which was the first turbofan engine tested in PSL. This second model of the ALF502R-5A serial number LF11 is a highly instrumented version of the previous engine. The PSL facility provides a continuous cloud of ice crystals with controlled characteristics of size and concentration, which are ingested by the engine during operation at simulated altitudes. Several of the previous operating points tested in the LF01 engine were duplicated to confirm repeatability in LF11. The instrumentation included video cameras to visually illustrate the accretion of ice in the low pressure compressor (LPC) exit guide vane region in order to confirm the ice accretion, which was suspected during the testing of the LF01. Traditional instrumentation included static pressure taps in the low pressure compressor inner and outer flow path walls, as well as total pressure and temperature rakes in the low pressure compressor region. The test data was utilized to determine the losses and blockages due to accretion in the exit guide vane region of the LPC. Multiple data points were analyzed with the Honeywell Customer Deck. A full engine roll back point was modeled with the Numerical Propulsion System Simulation (NPSS) code. The mean line compressor flow analysis code with ice crystal modeling was utilized to estimate the parameters that indicate the risk of accretion, as well as to estimate the degree of blockage and losses caused by accretion during a full engine roll back point. The analysis provided additional validation of the icing risk parameters within the LPC, as well as the creation of models for estimating the rates of blockage growth and losses.

  18. A statistical analysis of murine incisional and excisional acute wound models.

    PubMed

    Ansell, David M; Campbell, Laura; Thomason, Helen A; Brass, Andrew; Hardman, Matthew J

    2014-01-01

    Mice represent the most commonly used species for preclinical in vivo research. While incisional and excisional acute murine wound models are both frequently employed, there is little agreement on which model is optimum. Moreover, current lack of standardization of wounding procedure, analysis time point(s), method of assessment, and the use of individual wounds vs. individual animals as replicates makes it difficult to compare across studies. Here we have profiled secondary intention healing of incisional and excisional wounds within the same animal, assessing multiple parameters to determine the optimal methodology for future studies. We report that histology provides the least variable assessment of healing. Furthermore, histology alone (not planimetry) is able to detect accelerated healing in a castrated mouse model. Perhaps most importantly, we find virtually no correlation between wounds within the same animal, suggesting that use of wound (not animal) biological replicates is perfectly acceptable. Overall, these findings should guide and refine future studies, increasing the likelihood of detecting novel phenotypes while reducing the numbers of animals required for experimentation. © 2014 by the Wound Healing Society.

  19. A statistical analysis of murine incisional and excisional acute wound models

    PubMed Central

    Ansell, David M; Campbell, Laura; Thomason, Helen A; Brass, Andrew; Hardman, Matthew J

    2014-01-01

    Mice represent the most commonly used species for preclinical in vivo research. While incisional and excisional acute murine wound models are both frequently employed, there is little agreement on which model is optimum. Moreover, current lack of standardization of wounding procedure, analysis time point(s), method of assessment, and the use of individual wounds vs. individual animals as replicates makes it difficult to compare across studies. Here we have profiled secondary intention healing of incisional and excisional wounds within the same animal, assessing multiple parameters to determine the optimal methodology for future studies. We report that histology provides the least variable assessment of healing. Furthermore, histology alone (not planimetry) is able to detect accelerated healing in a castrated mouse model. Perhaps most importantly, we find virtually no correlation between wounds within the same animal, suggesting that use of wound (not animal) biological replicates is perfectly acceptable. Overall, these findings should guide and refine future studies, increasing the likelihood of detecting novel phenotypes while reducing the numbers of animals required for experimentation. PMID:24635179

  20. An overview of longitudinal data analysis methods for neurological research.

    PubMed

    Locascio, Joseph J; Atri, Alireza

    2011-01-01

    The purpose of this article is to provide a concise, broad and readily accessible overview of longitudinal data analysis methods, aimed to be a practical guide for clinical investigators in neurology. In general, we advise that older, traditional methods, including (1) simple regression of the dependent variable on a time measure, (2) analyzing a single summary subject level number that indexes changes for each subject and (3) a general linear model approach with a fixed-subject effect, should be reserved for quick, simple or preliminary analyses. We advocate the general use of mixed-random and fixed-effect regression models for analyses of most longitudinal clinical studies. Under restrictive situations or to provide validation, we recommend: (1) repeated-measure analysis of covariance (ANCOVA), (2) ANCOVA for two time points, (3) generalized estimating equations and (4) latent growth curve/structural equation models.

  1. Computer code for single-point thermodynamic analysis of hydrogen/oxygen expander-cycle rocket engines

    NASA Technical Reports Server (NTRS)

    Glassman, Arthur J.; Jones, Scott M.

    1991-01-01

    This analysis and this computer code apply to full, split, and dual expander cycles. Heat regeneration from the turbine exhaust to the pump exhaust is allowed. The combustion process is modeled as one of chemical equilibrium in an infinite-area or a finite-area combustor. Gas composition in the nozzle may be either equilibrium or frozen during expansion. This report, which serves as a users guide for the computer code, describes the system, the analysis methodology, and the program input and output. Sample calculations are included to show effects of key variables such as nozzle area ratio and oxidizer-to-fuel mass ratio.

  2. Human hair follicle organ culture: theory, application and perspectives.

    PubMed

    Langan, Ewan A; Philpott, Michael P; Kloepper, Jennifer E; Paus, Ralf

    2015-12-01

    For almost a quarter of a century, ex vivo studies of human scalp hair follicles (HFs) have permitted major advances in hair research, spanning diverse fields such as chronobiology, endocrinology, immunology, metabolism, mitochondrial biology, neurobiology, pharmacology, pigmentation and stem cell biology. Despite this, a comprehensive methodological guide to serum-free human HF organ culture (HFOC) that facilitates the selection and analysis of standard HF biological parameters and points out both research opportunities and pitfalls to newcomers to the field is still lacking. The current methods review aims to close an important gap in the literature and attempts to promote standardisation of human HFOC. We provide basic information outlining the establishment of HFOC through to detailed descriptions of the analysis of standard read-out parameters alongside practical examples. The guide closes by pointing out how serum-free HFOC can be utilised optimally to obtain previously inaccessible insights into human HF biology and pathology that are of interest to experimental dermatologists, geneticists, developmental biologists and (neuro-) endocrinologists alike and by highlighting novel applications of the model, including gene silencing and gene expression profiling of defined, laser capture-microdissected HF compartments. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Statistical prescission point model of fission fragment angular distributions

    NASA Astrophysics Data System (ADS)

    John, Bency; Kataria, S. K.

    1998-03-01

    In light of recent developments in fission studies such as slow saddle to scission motion and spin equilibration near the scission point, the theory of fission fragment angular distribution is examined and a new statistical prescission point model is developed. The conditional equilibrium of the collective angular bearing modes at the prescission point, which is guided mainly by their relaxation times and population probabilities, is taken into account in the present model. The present model gives a consistent description of the fragment angular and spin distributions for a wide variety of heavy and light ion induced fission reactions.

  4. Data extraction for complex meta-analysis (DECiMAL) guide.

    PubMed

    Pedder, Hugo; Sarri, Grammati; Keeney, Edna; Nunes, Vanessa; Dias, Sofia

    2016-12-13

    As more complex meta-analytical techniques such as network and multivariate meta-analyses become increasingly common, further pressures are placed on reviewers to extract data in a systematic and consistent manner. Failing to do this appropriately wastes time, resources and jeopardises accuracy. This guide (data extraction for complex meta-analysis (DECiMAL)) suggests a number of points to consider when collecting data, primarily aimed at systematic reviewers preparing data for meta-analysis. Network meta-analysis (NMA), multiple outcomes analysis and analysis combining different types of data are considered in a manner that can be useful across a range of data collection programmes. The guide has been shown to be both easy to learn and useful in a small pilot study.

  5. Cortical Surface Registration for Image-Guided Neurosurgery Using Laser-Range Scanning

    PubMed Central

    Sinha, Tuhin K.; Cash, David M.; Galloway, Robert L.; Weil, Robert J.

    2013-01-01

    In this paper, a method of acquiring intraoperative data using a laser range scanner (LRS) is presented within the context of model-updated image-guided surgery. Registering textured point clouds generated by the LRS to tomographic data is explored using established point-based and surface techniques as well as a novel method that incorporates geometry and intensity information via mutual information (SurfaceMI). Phantom registration studies were performed to examine accuracy and robustness for each framework. In addition, an in vivo registration is performed to demonstrate feasibility of the data acquisition system in the operating room. Results indicate that SurfaceMI performed better in many cases than point-based (PBR) and iterative closest point (ICP) methods for registration of textured point clouds. Mean target registration error (TRE) for simulated deep tissue targets in a phantom were 1.0 ± 0.2, 2.0 ± 0.3, and 1.2 ± 0.3 mm for PBR, ICP, and SurfaceMI, respectively. With regard to in vivo registration, the mean TRE of vessel contour points for each framework was 1.9 ± 1.0, 0 9 ± 0.6, and 1.3 ± 0.5 for PBR, ICP, and SurfaceMI, respectively. The methods discussed in this paper in conjunction with the quantitative data provide impetus for using LRS technology within the model-updated image-guided surgery framework. PMID:12906252

  6. Traffic analysis toolbox volume XIII : integrated corridor management analysis, modeling, and simulation guide

    DOT National Transportation Integrated Search

    2017-02-01

    As part of the Federal Highway Administration (FHWA) Traffic Analysis Toolbox (Volume XIII), this guide was designed to help corridor stakeholders implement the Integrated Corridor Management (ICM) Analysis, Modeling, and Simulation (AMS) methodology...

  7. Traffic analysis toolbox volume XIII : integrated corridor management analysis, modeling, and simulation guide.

    DOT National Transportation Integrated Search

    2017-02-01

    As part of the Federal Highway Administration (FHWA) Traffic Analysis Toolbox (Volume XIII), this guide was designed to help corridor stakeholders implement the Integrated Corridor Management (ICM) Analysis, Modeling, and Simulation (AMS) methodology...

  8. Micro-tattoo guided OCT imaging of site specific inflammation

    NASA Astrophysics Data System (ADS)

    Phillips, Kevin G.; Choudhury, Niloy; Samatham, Ravikant V.; Singh, Harvinder; Jacques, Steven L.

    2010-02-01

    Epithelial biologists studying human skin diseases such as cancer formation and psoriasis commonly utilize mouse models to characterize the interplay among cells and intracellular signal transduction pathways that result in programmed changes in gene expression and cellular behaviors. The information obtained from animal models is useful only when phenotypic presentations of disease recapitulate those observed in humans. Excision of tissues followed by histochemical analysis is currently the primary means of establishing the morphological presentation. Non invasive imaging of animal models provides an alternate means to characterize tissue morphology associated with the disease of interest in vivo. While useful, the ability to perform in vivo imaging at different time points in the same tissue location has been a challenge. This information is key to understanding site specific changes as the imaged tissue can now be extracted and analyzed for mRNA expression. We present a method employing a micro-tattoo to guide optical coherence tomography (OCT) imaging of ultraviolet induced inflammation over time in the same tissue locations.

  9. How Is the Freezing Point of a Binary Mixture of Liquids Related to the Composition? A Guided Inquiry Experiment

    ERIC Educational Resources Information Center

    Hunnicutt, Sally S.; Grushow, Alexander; Whitnell, Rob

    2017-01-01

    The principles of process-oriented guided inquiry learning (POGIL) are applied to a binary solid-liquid mixtures experiment. Over the course of two learning cycles, students predict, measure, and model the phase diagram of a mixture of fatty acids. The enthalpy of fusion of each fatty acid is determined from the results. This guided inquiry…

  10. BASINs and WEPP Climate Assessment Tools (CAT): Case Study Guide to Potential Applications (Final Report)

    EPA Science Inventory

    EPA announced the release of the final report, BASINs and WEPP Climate Assessment Tools (CAT): Case Study Guide to Potential Applications. This report supports application of two recently developed water modeling tools, the Better Assessment Science Integrating point & ...

  11. Four-chamber heart modeling and automatic segmentation for 3-D cardiac CT volumes using marginal space learning and steerable features.

    PubMed

    Zheng, Yefeng; Barbu, Adrian; Georgescu, Bogdan; Scheuering, Michael; Comaniciu, Dorin

    2008-11-01

    We propose an automatic four-chamber heart segmentation system for the quantitative functional analysis of the heart from cardiac computed tomography (CT) volumes. Two topics are discussed: heart modeling and automatic model fitting to an unseen volume. Heart modeling is a nontrivial task since the heart is a complex nonrigid organ. The model must be anatomically accurate, allow manual editing, and provide sufficient information to guide automatic detection and segmentation. Unlike previous work, we explicitly represent important landmarks (such as the valves and the ventricular septum cusps) among the control points of the model. The control points can be detected reliably to guide the automatic model fitting process. Using this model, we develop an efficient and robust approach for automatic heart chamber segmentation in 3-D CT volumes. We formulate the segmentation as a two-step learning problem: anatomical structure localization and boundary delineation. In both steps, we exploit the recent advances in learning discriminative models. A novel algorithm, marginal space learning (MSL), is introduced to solve the 9-D similarity transformation search problem for localizing the heart chambers. After determining the pose of the heart chambers, we estimate the 3-D shape through learning-based boundary delineation. The proposed method has been extensively tested on the largest dataset (with 323 volumes from 137 patients) ever reported in the literature. To the best of our knowledge, our system is the fastest with a speed of 4.0 s per volume (on a dual-core 3.2-GHz processor) for the automatic segmentation of all four chambers.

  12. PESTAN: Pesticide Analytical Model Version 4.0 User's Guide

    EPA Pesticide Factsheets

    The principal objective of this User's Guide to provide essential information on the aspects such as model conceptualization, model theory, assumptions and limitations, determination of input parameters, analysis of results and sensitivity analysis.

  13. The RTOG Outcomes Model: economic end points and measures.

    PubMed

    Konski, Andre; Watkins-Bruner, Deborah

    2004-03-01

    Recognising the value added by economic evaluations of clinical trials and the interaction of clinical, humanistic and economic end points, the Radiation Therapy Oncology Group (RTOG) has developed an Outcomes Model that guides the comprehensive assessment of this triad of end points. This paper will focus on the economic component of the model. The Economic Impact Committee was founded in 1994 to study the economic impact of clinical trials of cancer care. A steep learning curve ensued with considerable time initially spent understanding the methodology of economic analysis. Since then, economic analyses have been performed on RTOG clinical trials involving treatments for patients with non-small cell lung cancer, locally-advanced head and neck cancer and prostate cancer. As the care of cancer patients evolves with time, so has the economic analyses performed by the Economic Impact Committee. This paper documents the evolution of the cost-effectiveness analyses of RTOG from performing average cost-utility analysis to more technically sophisticated Monte Carlo simulation of Markov models, to incorporating prospective economic analyses as an initial end point. Briefly, results indicated that, accounting for quality-adjusted survival, concurrent chemotherapy and radiation for the treatment of non-small cell lung cancer, more aggressive radiation fractionation schedules for head and neck cancer and the addition of hormone therapy to radiation for prostate cancer are within the range of economically acceptable recommendations. The RTOG economic analyses have provided information that can further inform clinicians and policy makers of the value added of new or improved treatments.

  14. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    PubMed Central

    2011-01-01

    Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgical field through custom-made stereo-lithographic surgical guides. Methods In this work, a novel methodology is proposed for monitoring loss of accuracy in transferring CT dental information into periodontal surgical field. The methodology is based on integrating 3D data of anatomical (impression and cast) and preoperative (radiographic template) models, obtained by both CT and optical scanning processes. Results A clinical case, relative to a fully edentulous jaw patient, has been used as test case to assess the accuracy of the various steps concurring in manufacturing surgical guides. In particular, a surgical guide has been designed to place implants in the bone structure of the patient. The analysis of the results has allowed the clinician to monitor all the errors, which have been occurring step by step manufacturing the physical templates. Conclusions The use of an optical scanner, which has a higher resolution and accuracy than CT scanning, has demonstrated to be a valid support to control the precision of the various physical models adopted and to point out possible error sources. A case study regarding a fully edentulous patient has confirmed the feasibility of the proposed methodology. PMID:21338504

  15. An Overview of Longitudinal Data Analysis Methods for Neurological Research

    PubMed Central

    Locascio, Joseph J.; Atri, Alireza

    2011-01-01

    The purpose of this article is to provide a concise, broad and readily accessible overview of longitudinal data analysis methods, aimed to be a practical guide for clinical investigators in neurology. In general, we advise that older, traditional methods, including (1) simple regression of the dependent variable on a time measure, (2) analyzing a single summary subject level number that indexes changes for each subject and (3) a general linear model approach with a fixed-subject effect, should be reserved for quick, simple or preliminary analyses. We advocate the general use of mixed-random and fixed-effect regression models for analyses of most longitudinal clinical studies. Under restrictive situations or to provide validation, we recommend: (1) repeated-measure analysis of covariance (ANCOVA), (2) ANCOVA for two time points, (3) generalized estimating equations and (4) latent growth curve/structural equation models. PMID:22203825

  16. Toward efficient biomechanical-based deformable image registration of lungs for image-guided radiotherapy

    NASA Astrophysics Data System (ADS)

    Al-Mayah, Adil; Moseley, Joanne; Velec, Mike; Brock, Kristy

    2011-08-01

    Both accuracy and efficiency are critical for the implementation of biomechanical model-based deformable registration in clinical practice. The focus of this investigation is to evaluate the potential of improving the efficiency of the deformable image registration of the human lungs without loss of accuracy. Three-dimensional finite element models have been developed using image data of 14 lung cancer patients. Each model consists of two lungs, tumor and external body. Sliding of the lungs inside the chest cavity is modeled using a frictionless surface-based contact model. The effect of the type of element, finite deformation and elasticity on the accuracy and computing time is investigated. Linear and quadrilateral tetrahedral elements are used with linear and nonlinear geometric analysis. Two types of material properties are applied namely: elastic and hyperelastic. The accuracy of each of the four models is examined using a number of anatomical landmarks representing the vessels bifurcation points distributed across the lungs. The registration error is not significantly affected by the element type or linearity of analysis, with an average vector error of around 2.8 mm. The displacement differences between linear and nonlinear analysis methods are calculated for all lungs nodes and a maximum value of 3.6 mm is found in one of the nodes near the entrance of the bronchial tree into the lungs. The 95 percentile of displacement difference ranges between 0.4 and 0.8 mm. However, the time required for the analysis is reduced from 95 min in the quadratic elements nonlinear geometry model to 3.4 min in the linear element linear geometry model. Therefore using linear tetrahedral elements with linear elastic materials and linear geometry is preferable for modeling the breathing motion of lungs for image-guided radiotherapy applications.

  17. Automatic initialization for 3D bone registration

    NASA Astrophysics Data System (ADS)

    Foroughi, Pezhman; Taylor, Russell H.; Fichtinger, Gabor

    2008-03-01

    In image-guided bone surgery, sample points collected from the surface of the bone are registered to the preoperative CT model using well-known registration methods such as Iterative Closest Point (ICP). These techniques are generally very sensitive to the initial alignment of the datasets. Poor initialization significantly increases the chances of getting trapped local minima. In order to reduce the risk of local minima, the registration is manually initialized by locating the sample points close to the corresponding points on the CT model. In this paper, we present an automatic initialization method that aligns the sample points collected from the surface of pelvis with CT model of the pelvis. The main idea is to exploit a mean shape of pelvis created from a large number of CT scans as the prior knowledge to guide the initial alignment. The mean shape is constant for all registrations and facilitates the inclusion of application-specific information into the registration process. The CT model is first aligned with the mean shape using the bilateral symmetry of the pelvis and the similarity of multiple projections. The surface points collected using ultrasound are then aligned with the pelvis mean shape. This will, in turn, lead to initial alignment of the sample points with the CT model. The experiments using a dry pelvis and two cadavers show that the method can align the randomly dislocated datasets close enough for successful registration. The standard ICP has been used for final registration of datasets.

  18. An Analysis of Physician Assistant LibGuides: A Tool for Collection Development.

    PubMed

    Johnson, Catherine V; Johnson, Scott Y

    2017-01-01

    The Physician Assistant (PA) specialty encompasses many subject areas and requires many types of library resources. An analysis of PA LibGuides was performed to determine most frequently recommended resources. A sample of LibGuides from U.S. institutions accredited by the Accreditation Review Commission on Education for the Physician Assistant (ARC-PA) was included in this study. Resources presented on guides were tabulated and organized by resource type. Databases and point-of-care tools were the types of resources listed by the most LibGuides. There were over 1,000 books listed on the 45 guides, including over 600 unique books listed. There were fewer journals listed, only 163. Overall, while the 45 LibGuides evaluated list many unique resources in each category, a librarian can create an accepted list of the most frequently listed resources from the data gathered.

  19. Guided wave radiation from a point source in the proximity of a pipe bend

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brath, A. J.; Nagy, P. B.; Simonetti, F.

    Throughout the oil and gas industry corrosion and erosion damage monitoring play a central role in managing asset integrity. Recently, the use of guided wave technology in conjunction with tomography techniques has provided the possibility of obtaining point-by-point maps of wall thickness loss over the entire volume of a pipeline section between two ring arrays of ultrasonic transducers. However, current research has focused on straight pipes while little work has been done on pipe bends which are also the most susceptible to developing damage. Tomography of the bend is challenging due to the complexity and computational cost of the 3-Dmore » elastic model required to accurately describe guided wave propagation. To overcome this limitation, we introduce a 2-D anisotropic inhomogeneous acoustic model which represents a generalization of the conventional unwrapping used for straight pipes. The shortest-path ray-tracing method is then applied to the 2-D model to compute ray paths and predict the arrival times of the fundamental flexural mode, A0, excited by a point source on the straight section of pipe entering the bend and detected on the opposite side. Good agreement is found between predictions and experiments performed on an 8” diameter (D) pipe with 1.5 D bend radius. The 2-D model also reveals the existence of an acoustic lensing effect which leads to a focusing phenomenon also confirmed by the experiments. The computational efficiency of the 2-D model makes it ideally suited for tomography algorithms.« less

  20. Intraoperative brain tumor resection cavity characterization with conoscopic holography

    NASA Astrophysics Data System (ADS)

    Simpson, Amber L.; Burgner, Jessica; Chen, Ishita; Pheiffer, Thomas S.; Sun, Kay; Thompson, Reid C.; Webster, Robert J., III; Miga, Michael I.

    2012-02-01

    Brain shift compromises the accuracy of neurosurgical image-guided interventions if not corrected by either intraoperative imaging or computational modeling. The latter requires intraoperative sparse measurements for constraining and driving model-based compensation strategies. Conoscopic holography, an interferometric technique that measures the distance of a laser light illuminated surface point from a fixed laser source, was recently proposed for non-contact surface data acquisition in image-guided surgery and is used here for validation of our modeling strategies. In this contribution, we use this inexpensive, hand-held conoscopic holography device for intraoperative validation of our computational modeling approach to correcting for brain shift. Laser range scan, instrument swabbing, and conoscopic holography data sets were collected from two patients undergoing brain tumor resection therapy at Vanderbilt University Medical Center. The results of our study indicate that conoscopic holography is a promising method for surface acquisition since it requires no contact with delicate tissues and can characterize the extents of structures within confined spaces. We demonstrate that for two clinical cases, the acquired conoprobe points align with our model-updated images better than the uncorrected images lending further evidence that computational modeling approaches improve the accuracy of image-guided surgical interventions in the presence of soft tissue deformations.

  1. Quantitative comparison of the application accuracy between NDI and IGT tracking systems

    NASA Astrophysics Data System (ADS)

    Li, Qinghang; Zamorano, Lucia J.; Jiang, Charlie Z. W.; Gong, JianXing; Diaz, Fernando

    1999-07-01

    The application accuracy is a crucial factor for the stereotactic surgical localization system in which space digitization system is one of the most important part of equipment. In this study we compared the application accuracy of using the OPTOTRAK space digitization system (OPTOTRAK 3020, Northern Digital, Waterloo, CAN) and FlashPoint Model 3000 and 5000 3-D digitizer systems (FlashPoint Model 3000 and 5000, Image Guided Surgery Technology Inc., Boulder, CO 80301, USA) for interactive localization of intracranial lesions. A phantom was mounted with the implantable frameless marker system (Fischer- Leibinger, Freiburg, Germany) which randomly distributed markers on the surface of the phantom. The target point was digitized and the coordinates were recorded and compared with reference points. The differences from the reference points were used as the deviation from the `true point'. The mean square root was calculated to show the sum of vectors. A paired t-test was used to analyze results. The results of the phantom showed that the mean square roots were 0.76 +/- 0.54 mm for the OPTOTRAK system and 1.23 +/- 0.53 mm for FlashPoint Model 3000 3-D digitizer system and 1.00 +/- 0.42 mm for FlashPoint Model 3000 3-D digitizer system in the 1 mm sections of CT scan. This preliminary results showed that there is no significant difference between two tracking systems. Both of them can be used for image guided surgery procedure.

  2. OCD: The offshore and coastal dispersion model. Volume 1. User's guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DiCristofaro, D.C.; Hanna, S.R.

    1989-11-01

    The Offshore and Coastal Dispersion (OCD) Model has been developed to simulate the effect of offshore emissions from point, area, or line sources on the air quality of coastal regions. The OCD model was adapted from the EPA guideline model MPTER (EPA, 1980). Modifications were made to incorporate overwater plume transport and dispersion as well as changes that occur as the plume crosses the shoreline. This is a revised OCD model, the fourth version to date. The volume is the User's Guide which includes a Model overview, technical description, user's instructions, and notes on model evaluation and results.

  3. [Navigation in implantology: Accuracy assessment regarding the literature].

    PubMed

    Barrak, Ibrahim Ádám; Varga, Endre; Piffko, József

    2016-06-01

    Our objective was to assess the literature regarding the accuracy of the different static guided systems. After applying electronic literature search we found 661 articles. After reviewing 139 articles, the authors chose 52 articles for full-text evaluation. 24 studies involved accuracy measurements. Fourteen of our selected references were clinical and ten of them were in vitro (modell or cadaver). Variance-analysis (Tukey's post-hoc test; p < 0.05) was conducted to summarize the selected publications. Regarding 2819 results the average mean error at the entry point was 0.98 mm. At the level of the apex the average deviation was 1.29 mm while the mean of the angular deviation was 3,96 degrees. Significant difference could be observed between the two methods of implant placement (partially and fully guided sequence) in terms of deviation at the entry point, apex and angular deviation. Different levels of quality and quantity of evidence were available for assessing the accuracy of the different computer-assisted implant placement. The rapidly evolving field of digital dentistry and the new developments will further improve the accuracy of guided implant placement. In the interest of being able to draw dependable conclusions and for the further evaluation of the parameters used for accuracy measurements, randomized, controlled single or multi-centered clinical trials are necessary.

  4. Toward a Value for Guided Rafting on Southern Rivers

    Treesearch

    J. Michael Bowker; Donald B.K. English; Jason A. Donovan

    1996-01-01

    This study examines per trip consumer surplus associated with guided whitewater rafting on two southern rivers. First, household recreation demand functions are estimated based on the individual travel cost model using truncated count data regression methods and alternative price specifications. Findings show mean per trip consumer surplus point estimates between $89...

  5. User's Guide for the Agricultural Non-Point Source (AGNPS) Pollution Model Data Generator

    USGS Publications Warehouse

    Finn, Michael P.; Scheidt, Douglas J.; Jaromack, Gregory M.

    2003-01-01

    BACKGROUND Throughout this user guide, we refer to datasets that we used in conjunction with developing of this software for supporting cartographic research and producing the datasets to conduct research. However, this software can be used with these datasets or with more 'generic' versions of data of the appropriate type. For example, throughout the guide, we refer to national land cover data (NLCD) and digital elevation model (DEM) data from the U.S. Geological Survey (USGS) at a 30-m resolution, but any digital terrain model or land cover data at any appropriate resolution will produce results. Another key point to keep in mind is to use a consistent data resolution for all the datasets per model run. The U.S. Department of Agriculture (USDA) developed the Agricultural Nonpoint Source (AGNPS) pollution model of watershed hydrology in response to the complex problem of managing nonpoint sources of pollution. AGNPS simulates the behavior of runoff, sediment, and nutrient transport from watersheds that have agriculture as their prime use. The model operates on a cell basis and is a distributed parameter, event-based model. The model requires 22 input parameters. Output parameters are grouped primarily by hydrology, sediment, and chemical output (Young and others, 1995.) Elevation, land cover, and soil are the base data from which to extract the 22 input parameters required by the AGNPS. For automatic parameter extraction, follow the general process described in this guide of extraction from the geospatial data through the AGNPS Data Generator to generate input parameters required by the pollution model (Finn and others, 2002.)

  6. Galerkin Models Enhancements for Flow Control

    NASA Astrophysics Data System (ADS)

    Tadmor, Gilead; Lehmann, Oliver; Noack, Bernd R.; Morzyński, Marek

    Low order Galerkin models were originally introduced as an effective tool for stability analysis of fixed points and, later, of attractors, in nonlinear distributed systems. An evolving interest in their use as low complexity dynamical models, goes well beyond that original intent. It exposes often severe weaknesses of low order Galerkin models as dynamic predictors and has motivated efforts, spanning nearly three decades, to alleviate these shortcomings. Transients across natural and enforced variations in the operating point, unsteady inflow, boundary actuation and both aeroelastic and actuated boundary motion, are hallmarks of current and envisioned needs in feedback flow control applications, bringing these shortcomings to even higher prominence. Building on the discussion in our previous chapters, we shall now review changes in the Galerkin paradigm that aim to create a mathematically and physically consistent modeling framework, that remove what are otherwise intractable roadblocks. We shall then highlight some guiding design principles that are especially important in the context of these models. We shall continue to use the simple example of wake flow instabilities to illustrate the various issues, ideas and methods that will be discussed in this chapter.

  7. Automated planning of ablation targets in atrial fibrillation treatment

    NASA Astrophysics Data System (ADS)

    Keustermans, Johannes; De Buck, Stijn; Heidbüchel, Hein; Suetens, Paul

    2011-03-01

    Catheter based radio-frequency ablation is used as an invasive treatment of atrial fibrillation. This procedure is often guided by the use of 3D anatomical models obtained from CT, MRI or rotational angiography. During the intervention the operator accurately guides the catheter to prespecified target ablation lines. The planning stage, however, can be time consuming and operator dependent which is suboptimal both from a cost and health perspective. Therefore, we present a novel statistical model-based algorithm for locating ablation targets from 3D rotational angiography images. Based on a training data set of 20 patients, consisting of 3D rotational angiography images with 30 manually indicated ablation points, a statistical local appearance and shape model is built. The local appearance model is based on local image descriptors to capture the intensity patterns around each ablation point. The local shape model is constructed by embedding the ablation points in an undirected graph and imposing that each ablation point only interacts with its neighbors. Identifying the ablation points on a new 3D rotational angiography image is performed by proposing a set of possible candidate locations for each ablation point, as such, converting the problem into a labeling problem. The algorithm is validated using a leave-one-out-approach on the training data set, by computing the distance between the ablation lines obtained by the algorithm and the manually identified ablation points. The distance error is equal to 3.8+/-2.9 mm. As ablation lesion size is around 5-7 mm, automated planning of ablation targets by the presented approach is sufficiently accurate.

  8. Aircraft/Air Traffic Management Functional Analysis Model. Version 2.0; User's Guide

    NASA Technical Reports Server (NTRS)

    Etheridge, Melvin; Plugge, Joana; Retina, Nusrat

    1998-01-01

    The Aircraft/Air Traffic Management Functional Analysis Model, Version 2.0 (FAM 2.0), is a discrete event simulation model designed to support analysis of alternative concepts in air traffic management and control. FAM 2.0 was developed by the Logistics Management Institute (LMI) a National Aeronautics and Space Administration (NASA) contract. This document provides a guide for using the model in analysis. Those interested in making enhancements or modification to the model should consult the companion document, Aircraft/Air Traffic Management Functional Analysis Model, Version 2.0 Technical Description.

  9. The Optimization of Four-Stage Low Pressure Turbine with Outlet Guide Vane

    NASA Astrophysics Data System (ADS)

    Matveev, V.; Baturin, O.; Popov, G.

    2018-01-01

    The goal of the research was to improve efficiency of four-stage low-pressure turbine with outlet guide vane (LPT) at the design point by optimization the shape of all turbine stator vanes and the stagger angles of all rotor blades. The LPT mathematical model was created by using NUMECA FineTurbo software. Several constraints were imposed the mass flow rate through the LPT and the total pressure ratio at the design point may vary within ±0.5% from the original. Parameters of the stator blade shape and rotor blades stagger angles were obtained. This new geometry of the LPT blades produce a 0.8% increase in efficiency at the design point.

  10. Three-dimensional planning and use of patient-specific guides improve glenoid component position: an in vitro study.

    PubMed

    Walch, Gilles; Vezeridis, Peter S; Boileau, Pascal; Deransart, Pierric; Chaoui, Jean

    2015-02-01

    Glenoid component positioning is a key factor for success in total shoulder arthroplasty. Three-dimensional (3D) measurements of glenoid retroversion, inclination, and humeral head subluxation are helpful tools for preoperative planning. The purpose of this study was to assess the reliability and precision of a novel surgical method for placing the glenoid component with use of patient-specific templates created by preoperative surgical planning and 3D modeling. A preoperative computed tomography examination of cadaveric scapulae (N = 18) was performed. The glenoid implants were virtually placed, and patient-specific guides were created to direct the guide pin into the desired orientation and position in the glenoid. The 3D orientation and position of the guide pin were evaluated by performing a postoperative computed tomography scan for each scapula. The differences between the preoperative planning and the achieved result were analyzed. The mean error in 3D orientation of the guide pin was 2.39°, the mean entry point position error was 1.05 mm, and the mean inclination angle error was 1.42°. The average error in the version angle was 1.64°. There were no technical difficulties or complications related to use of patient-specific guides for guide pin placement. Quantitative analysis of guide pin positioning demonstrated a good correlation between preoperative planning and the achieved position of the guide pin. This study demonstrates the reliability and precision of preoperative planning software and patient-specific guides for glenoid component placement in total shoulder arthroplasty. Copyright © 2015. Published by Elsevier Inc.

  11. Analysis on influence of guide vanes closure laws of pump-turbine on load rejection transient process

    NASA Astrophysics Data System (ADS)

    Yao, Z.; Bi, H. L.; Huang, Q. S.; Li, Z. J.; Wang, Z. W.

    2013-12-01

    In load rejection transient process, the sudden shut down of guide vanes may cause units speed rise and a sharp increase in water hammer pressure of diversion system, which endangers the safety operation of the power plant. Adopting reasonable guide vane closure law is a kind of economic and effective measurement to reduce the water hammer pressure and limit rotational speed increases. In this paper, combined with Guangzhou Pumped Storage Power Station plant A, the load rejection condition under different guide vanes closure laws is calculated and the key factor of guide vanes closure laws on the impact of the load rejection transition process is analyzed. The different inflection points, which are the closure modes, on the impact of unit speed change, water level fluctuation of surge tank, and the pressure fluctuation of volute inlet and draft tube inlet are further discussed. By compared with the calculation results, a reasonable guide vanes inflection point position can be determined according to security requirements and a reasonable guide vanes closure law can be attained to effectively coordinate the unit speed rise and the rapid pressure change in the load rejection transient process.

  12. Hand-eye calibration using a target registration error model.

    PubMed

    Chen, Elvis C S; Morgan, Isabella; Jayarathne, Uditha; Ma, Burton; Peters, Terry M

    2017-10-01

    Surgical cameras are prevalent in modern operating theatres and are often used as a surrogate for direct vision. Visualisation techniques (e.g. image fusion) made possible by tracking the camera require accurate hand-eye calibration between the camera and the tracking system. The authors introduce the concept of 'guided hand-eye calibration', where calibration measurements are facilitated by a target registration error (TRE) model. They formulate hand-eye calibration as a registration problem between homologous point-line pairs. For each measurement, the position of a monochromatic ball-tip stylus (a point) and its projection onto the image (a line) is recorded, and the TRE of the resulting calibration is predicted using a TRE model. The TRE model is then used to guide the placement of the calibration tool, so that the subsequent measurement minimises the predicted TRE. Assessing TRE after each measurement produces accurate calibration using a minimal number of measurements. As a proof of principle, they evaluated guided calibration using a webcam and an endoscopic camera. Their endoscopic camera results suggest that millimetre TRE is achievable when at least 15 measurements are acquired with the tracker sensor ∼80 cm away on the laparoscope handle for a target ∼20 cm away from the camera.

  13. Modeling seasonal detection patterns for burrowing owl surveys

    Treesearch

    Quresh S. Latif; Kathleen D. Fleming; Cameron Barrows; John T. Rotenberry

    2012-01-01

    To guide monitoring of burrowing owls (Athene cunicularia) in the Coachella Valley, California, USA, we analyzed survey-method-specific seasonal variation in detectability. Point-based call-broadcast surveys yielded high early season detectability that then declined through time, whereas detectability on driving surveys increased through the season. Point surveys...

  14. A comparative analysis of speed profile models for wrist pointing movements.

    PubMed

    Vaisman, Lev; Dipietro, Laura; Krebs, Hermano Igo

    2013-09-01

    Following two decades of design and clinical research on robot-mediated therapy for the shoulder and elbow, therapeutic robotic devices for other joints are being proposed: several research groups including ours have designed robots for the wrist, either to be used as stand-alone devices or in conjunction with shoulder and elbow devices. However, in contrast with robots for the shoulder and elbow which were able to take advantage of descriptive kinematic models developed in neuroscience for the past 30 years, design of wrist robots controllers cannot rely on similar prior art: wrist movement kinematics has been largely unexplored. This study aimed at examining speed profiles of fast, visually evoked, visually guided, target-directed human wrist pointing movements. One thousand three-hundred ninety-eight (1398) trials were recorded from seven unimpaired subjects who performed center-out flexion/extension and abduction/adduction wrist movements and fitted with 19 models previously proposed for describing reaching speed profiles. A nonlinear, least squares optimization procedure extracted parameters' sets that minimized error between experimental and reconstructed data. Models' performances were compared based on their ability to reconstruct experimental data. Results suggest that the support-bounded lognormal is the best model for speed profiles of fast, wrist pointing movements. Applications include design of control algorithms for therapeutic wrist robots and quantitative metrics of motor recovery.

  15. WATER DISTRIBUTION SYSTEM ANALYSIS: FIELD STUDIES, MODELING AND MANAGEMENT

    EPA Science Inventory

    The user‘s guide entitled “Water Distribution System Analysis: Field Studies, Modeling and Management” is a reference guide for water utilities and an extensive summarization of information designed to provide drinking water utility personnel (and related consultants and research...

  16. Simple Thermal Environment Model (STEM) User's Guide

    NASA Technical Reports Server (NTRS)

    Justus, C.G.; Batts, G. W.; Anderson, B. J.; James, B. F.

    2001-01-01

    This report presents a Simple Thermal Environment Model (STEM) for determining appropriate engineering design values to specify the thermal environment of Earth-orbiting satellites. The thermal environment of a satellite, consists of three components: (1) direct solar radiation, (2) Earth-atmosphere reflected shortwave radiation, as characterized by Earth's albedo, and (3) Earth-atmosphere-emitted outgoing longwave radiation (OLR). This report, together with a companion "guidelines" report provides methodology and guidelines for selecting "design points" for thermal environment parameters for satellites and spacecraft systems. The methods and models reported here are outgrowths of Earth Radiation Budget Experiment (ERBE) satellite data analysis and thermal environment specifications discussed by Anderson and Smith (1994). In large part, this report is intended to update (and supersede) those results.

  17. Prostate cancer gene 3 and multiparametric magnetic resonance can reduce unnecessary biopsies: decision curve analysis to evaluate predictive models.

    PubMed

    Busetto, Gian Maria; De Berardinis, Ettore; Sciarra, Alessandro; Panebianco, Valeria; Giovannone, Riccardo; Rosato, Stefano; D'Errigo, Paola; Di Silverio, Franco; Gentile, Vincenzo; Salciccia, Stefano

    2013-12-01

    To overcome the well-known prostate-specific antigen limits, several new biomarkers have been proposed. Since its introduction in clinical practice, the urinary prostate cancer gene 3 (PCA3) assay has shown promising results for prostate cancer (PC) detection. Furthermore, multiparametric magnetic resonance imaging (mMRI) has the ability to better describe several aspects of PC. A prospective study of 171 patients with negative prostate biopsy findings and a persistent high prostate-specific antigen level was conducted to assess the role of mMRI and PCA3 in identifying PC. All patients underwent the PCA3 test and mMRI before a second transrectal ultrasound-guided prostate biopsy. The accuracy and reliability of PCA3 (3 different cutoff points) and mMRI were evaluated. Four multivariate logistic regression models were analyzed, in terms of discrimination and the cost benefit, to assess the clinical role of PCA3 and mMRI in predicting the biopsy outcome. A decision curve analysis was also plotted. Repeated transrectal ultrasound-guided biopsy identified 68 new cases (41.7%) of PC. The sensitivity and specificity of the PCA3 test and mMRI was 68% and 49% and 74% and 90%, respectively. Evaluating the regression models, the best discrimination (area under the curve 0.808) was obtained using the full model (base clinical model plus mMRI and PCA3). The decision curve analysis, to evaluate the cost/benefit ratio, showed good performance in predicting PC with the model that included mMRI and PCA3. mMRI increased the accuracy and sensitivity of the PCA3 test, and the use of the full model significantly improved the cost/benefit ratio, avoiding unnecessary biopsies. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Reproducibility of tract segmentation between sessions using an unsupervised modelling-based approach.

    PubMed

    Clayden, Jonathan D; Storkey, Amos J; Muñoz Maniega, Susana; Bastin, Mark E

    2009-04-01

    This work describes a reproducibility analysis of scalar water diffusion parameters, measured within white matter tracts segmented using a probabilistic shape modelling method. In common with previously reported neighbourhood tractography (NT) work, the technique optimises seed point placement for fibre tracking by matching the tracts generated using a number of candidate points against a reference tract, which is derived from a white matter atlas in the present study. No direct constraints are applied to the fibre tracking results. An Expectation-Maximisation algorithm is used to fully automate the procedure, and make dramatically more efficient use of data than earlier NT methods. Within-subject and between-subject variances for fractional anisotropy and mean diffusivity within the tracts are then separated using a random effects model. We find test-retest coefficients of variation (CVs) similar to those reported in another study using landmark-guided single seed points; and subject to subject CVs similar to a constraint-based multiple ROI method. We conclude that our approach is at least as effective as other methods for tract segmentation using tractography, whilst also having some additional benefits, such as its provision of a goodness-of-match measure for each segmentation.

  19. Introduction to Listening: A Training Unit for Adults

    ERIC Educational Resources Information Center

    Schieber, Lisa M.

    2009-01-01

    The following instructional unit contains all the elements needed to complete a two hour training unit on Listening. Included in the unit are: training objectives, task analysis, needs analysis assessment, training plan, participant guide, and Power Point Presentation slides. A bibliography is included.

  20. A cost-effectiveness model to personalize antiviral therapy in naive patients with genotype 1 chronic hepatitis C.

    PubMed

    Iannazzo, Sergio; Colombatto, Piero; Ricco, Gabriele; Oliveri, Filippo; Bonino, Ferruccio; Brunetto, Maurizia R

    2015-03-01

    Rapid virologic response is the best predictor of sustained virologic response with dual therapy in genotype-1 chronic hepatitis C, and its evaluation was proposed to tailor triple therapy in F0-F2 patients. Bio-mathematical modelling of viral dynamics during dual therapy has potentially higher accuracy than rapid virologic in the identification of patients who will eventually achieve sustained response. Study's objective was the cost-effectiveness analysis of a personalized therapy in naïve F0-F2 patients with chronic hepatitis C based on a bio-mathematical model (model-guided strategy) rather than on rapid virologic response (guideline-guided strategy). A deterministic bio-mathematical model of the infected cell dynamics was validated in a cohort of 135 patients treated with dual therapy. A decision-analytic economic model was then developed to compare model-guided and guideline-guided strategies in the Italian setting. The outcomes of the cost-effectiveness analysis with model-guided and guideline-guided strategy were 19.1-19.4 and 18.9-19.3 quality-adjusted-life-years. Total per-patient lifetime costs were €25,200-€26,000 with model-guided strategy and €28,800-€29,900 with guideline-guided strategy. When comparing model-guided with guideline-guided strategy the former resulted more effective and less costly. The adoption of the bio-mathematical predictive criterion has the potential to improve the cost-effectiveness of a personalized therapy for chronic hepatitis C, reserving triple therapy for those patients who really need it. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  1. To stress or not to stress: a question of models.

    PubMed

    Gray, J Megan; Chaouloff, Francis; Hill, Matthew N

    2015-01-05

    Stress research is a rapidly evolving field that encompasses numerous disciplines ranging from neuroscience to metabolism. With many new researchers migrating into the field, navigating the hows and whys of specific research questions can sometimes be enigmatic given the availability of so many models in the stress field. Additionally, as with every field, there are many seemingly minor experimental details that can have dramatic influences on data interpretation, although many of these are unknown to those not familiar with the field. The aim of this overview is to provide some suggestions and points to guide researchers moving into the stress field and highlight relevant methodological points that they should consider when choosing a model for stress and deciding how to structure a study. We briefly provide a primer on the basics of endpoint measurements in the stress field, factors to consider when choosing a model for acute stress, the difference between repeated and chronic stress, and importantly, influencing variables that modulate endpoints of analysis in stress work. Copyright © 2015 John Wiley & Sons, Inc.

  2. A Beginner's Guide to the Solow Model

    ERIC Educational Resources Information Center

    Stein, Sheldon H.

    2007-01-01

    The Solow model is widely regarded as the workhorse model of the theory of economic growth. Although at one point this model was first encountered in graduate school, it has since filtered down to the intermediate and, occasionally, to the principles of macroeconomics course. Many have commented on how difficult it is to teach the Solow model to…

  3. Automated Guided-Wave Scanning Developed to Characterize Materials and Detect Defects

    NASA Technical Reports Server (NTRS)

    Martin, Richard E.; Gyekenyeski, Andrew L.; Roth, Don J.

    2004-01-01

    The Nondestructive Evaluation (NDE) Group of the Optical Instrumentation Technology Branch at the NASA Glenn Research Center has developed a scanning system that uses guided waves to characterize materials and detect defects. The technique uses two ultrasonic transducers to interrogate the condition of a material. The sending transducer introduces an ultrasonic pulse at a point on the surface of the specimen, and the receiving transducer detects the signal after it has passed through the material. The aim of the method is to correlate certain parameters in both the time and frequency domains of the detected waveform to characteristics of the material between the two transducers. The scanning system is shown. The waveform parameters of interest include the attenuation due to internal damping, waveform shape parameters, and frequency shifts due to material changes. For the most part, guided waves are used to gauge the damage state and defect growth of materials subjected to various mechanical or environmental loads. The technique has been applied to polymer matrix composites, ceramic matrix composites, and metal matrix composites as well as metallic alloys. Historically, guided wave analysis has been a point-by-point, manual technique with waveforms collected at discrete locations and postprocessed. Data collection and analysis of this type limits the amount of detail that can be obtained. Also, the manual movement of the sensors is prone to user error and is time consuming. The development of an automated guided-wave scanning system has allowed the method to be applied to a wide variety of materials in a consistent, repeatable manner. Experimental studies have been conducted to determine the repeatability of the system as well as compare the results obtained using more traditional NDE methods. The following screen capture shows guided-wave scan results for a ceramic matrix composite plate, including images for each of nine calculated parameters. The system can display up to 18 different wave parameters. Multiple scans of the test specimen demonstrated excellent repeatability in the measurement of all the guided-wave parameters, far exceeding the traditional point-by-point technique. In addition, the scan was able to detect a subsurface defect that was confirmed using flash thermography This technology is being further refined to provide a more robust and efficient software environment. Future hardware upgrades will allow for multiple receiving transducers and the ability to scan more complex surfaces. This work supports composite materials development and testing under the Ultra-Efficient Engine Technology (UEET) Project, but it also will be applied to other material systems under development for a wide range of applications.

  4. Digital Avionics Information System (DAIS): Training Requirements Analysis Model Users Guide. Final Report.

    ERIC Educational Resources Information Center

    Czuchry, Andrew J.; And Others

    This user's guide describes the functions, logical operations and subroutines, input data requirements, and available outputs of the Training Requirements Analysis Model (TRAMOD), a computerized analytical life cycle cost modeling system for use in the early stages of system design. Operable in a stand-alone mode, TRAMOD can be used for the…

  5. Modeling the Deterioration of Engine and Low Pressure Compressor Performance During a Roll Back Event Due to Ice Accretion

    NASA Technical Reports Server (NTRS)

    Veres, Joseph P.; Jorgenson, Philip, C. E.; Jones, Scott M.

    2014-01-01

    The main focus of this study is to apply a computational tool for the flow analysis of the engine that has been tested with ice crystal ingestion in the Propulsion Systems Laboratory (PSL) of NASA Glenn Research Center. A data point was selected for analysis during which the engine experienced a full roll back event due to the ice accretion on the blades and flow path of the low pressure compressor. The computational tool consists of the Numerical Propulsion System Simulation (NPSS) engine system thermodynamic cycle code, and an Euler-based compressor flow analysis code, that has an ice particle melt estimation code with the capability of determining the rate of sublimation, melting, and evaporation through the compressor blade rows. Decreasing the performance characteristics of the low pressure compressor (LPC) within the NPSS cycle analysis resulted in matching the overall engine performance parameters measured during testing at data points in short time intervals through the progression of the roll back event. Detailed analysis of the fan-core and LPC with the compressor flow analysis code simulated the effects of ice accretion by increasing the aerodynamic blockage and pressure losses through the low pressure compressor until achieving a match with the NPSS cycle analysis results, at each scan. With the additional blockages and losses in the LPC, the compressor flow analysis code results were able to numerically reproduce the performance that was determined by the NPSS cycle analysis, which was in agreement with the PSL engine test data. The compressor flow analysis indicated that the blockage due to ice accretion in the LPC exit guide vane stators caused the exit guide vane (EGV) to be nearly choked, significantly reducing the air flow rate into the core. This caused the LPC to eventually be in stall due to increasing levels of diffusion in the rotors and high incidence angles in the inlet guide vane (IGV) and EGV stators. The flow analysis indicating compressor stall is substantiated by the video images of the IGV taken during the PSL test, which showed water on the surface of the IGV flowing upstream out of the engine, indicating flow reversal, which is characteristic of a stalled compressor.

  6. Care guides: an examination of occupational conflict and role relationships in primary care.

    PubMed

    Wholey, Douglas R; White, Katie M; Adair, Richard; Christianson, Jon B; Lee, Suhna; Elumba, Deborah

    2013-01-01

    Improving the efficiency and effectiveness of primary care treatment of patients with chronic illness is an important goal in reforming the U.S. health care system. Reducing occupational conflicts and creating interdependent primary care teams is crucial for the effective functioning of new models being developed to reorganize chronic care. Occupational conflict, role interdependence, and resistance to change in a proof-of-concept pilot test of one such model that uses a new kind of employee in the primary care office, a "care guide," were analyzed. Care guides are lay individuals who help chronic disease patients and their providers achieve standard health goals. The aim of this study was to examine the development of occupational boundaries, interdependence of care guides and primary care team members, and acceptance by clinic employees of this new kind of health worker. A mixed methods, pilot study was conducted using qualitative analysis; clinic, provider, and patient surveys; administrative data; and multivariate analysis. Qualitative analysis examined the emergence of the care guide role. Administrative data and surveys were used to examine patterns of interdependence between care guides, physicians, team members, and clinic staff; obtain physician evaluations of the care guide role; and evaluate the effect of care guides on patient perceptions of care coordination and follow-up. Evaluation of implementation of the care guide model showed that (a) the care guide scope of practice was clearly defined; (b) interdependent relationships between care guides and providers were formed; (c) relational triads consisting of patient, care guide, and physician were created; (d) patients and providers were supported in managing chronic disease; and (e) resistance to this model among traditional employees was minimized. The feasibility of implementing a new care model for chronic disease management in the primary care setting, identifying factors associated with a positive organizational experience, was shown in this study.

  7. A novel technique for reference point generation to aid in intraoral scan alignment.

    PubMed

    Renne, Walter G; Evans, Zachary P; Mennito, Anthony; Ludlow, Mark

    2017-11-12

    When using a completely digital workflow on larger prosthetic cases it is often difficult to communicate to the laboratory or chairside Computer Aided Design and Computer Aided Manufacturing system the provisional prosthetic information. The problem arises when common hard tissue data points are limited or non-existent such as in complete arch cases in which the 3D model of the complete arch provisional restorations must be aligned perfectly with the 3D model of the complete arch preparations. In these instances, soft tissue is not enough to ensure an accurate automatic or manual alignment due to a lack of well-defined reference points. A new technique is proposed for the proper digital alignment of the 3D virtual model of the provisional prosthetic to the 3D virtual model of the prepared teeth in cases where common and coincident hard tissue data points are limited. Clinical considerations: A technique is described in which fiducial composite resin dots are temporarily placed on the intraoral keratinized tissue in strategic locations prior to final impressions. These fiducial dots provide coincident and clear 3D data points that when scanned into a digital impression allow superimposition of the 3D models. Composite resin dots on keratinized tissue were successful at allowing accurate merging of provisional restoration and post-preparation 3D models for the purpose of using the provisional restorations as a guide for final CLINICAL SIGNIFICANCE: Composite resin dots placed temporarily on attached tissue were successful at allowing accurate merging of the provisional restoration 3D models to the preparation 3D models for the purposes of using the provisional restorations as a guide for final restoration design and manufacturing. In this case, they allowed precise superimposition of the 3D models made in the absence of any other hard tissue reference points, resulting in the fabrication of ideal final restorations. © 2017 Wiley Periodicals, Inc.

  8. Architectural approaches for HL7-based health information systems implementation.

    PubMed

    López, D M; Blobel, B

    2010-01-01

    Information systems integration is hard, especially when semantic and business process interoperability requirements need to be met. To succeed, a unified methodology, approaching different aspects of systems architecture such as business, information, computational, engineering and technology viewpoints, has to be considered. The paper contributes with an analysis and demonstration on how the HL7 standard set can support health information systems integration. Based on the Health Information Systems Development Framework (HIS-DF), common architectural models for HIS integration are analyzed. The framework is a standard-based, consistent, comprehensive, customizable, scalable methodology that supports the design of semantically interoperable health information systems and components. Three main architectural models for system integration are analyzed: the point to point interface, the messages server and the mediator models. Point to point interface and messages server models are completely supported by traditional HL7 version 2 and version 3 messaging. The HL7 v3 standard specification, combined with service-oriented, model-driven approaches provided by HIS-DF, makes the mediator model possible. The different integration scenarios are illustrated by describing a proof-of-concept implementation of an integrated public health surveillance system based on Enterprise Java Beans technology. Selecting the appropriate integration architecture is a fundamental issue of any software development project. HIS-DF provides a unique methodological approach guiding the development of healthcare integration projects. The mediator model - offered by the HIS-DF and supported in HL7 v3 artifacts - is the more promising one promoting the development of open, reusable, flexible, semantically interoperable, platform-independent, service-oriented and standard-based health information systems.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raffray, A.R.; Meier, W.; Abdel-Khalik, S.

    For thick liquid wall concepts, it is important to understand the different mechanisms affecting the chamber dynamics and the state of the chamber prior to each shot a compared with requirements from the driver and target. These include ablation mechanisms, vapor transport and control, possible aerosol formation, as well as protective jet behavior. This paper was motivated by a town meeting on this subject which helped identify the major issues, assess the latest results, review the capabilities of existing modeling and experimental facilities with respect to addressing remaining issues, and helping guide future analysis and R&D efforts; the paper coversmore » these exact points.« less

  10. NWTC Helps Guide U.S. Offshore R&D; NREL (National Renewable Energy Laboratory)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2015-07-01

    The National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory (NREL) is helping guide our nation's research-and-development effort in offshore renewable energy, which includes: Design, modeling, and analysis tools; Device and component testing; Resource characterization; Economic modeling and analysis; Grid integration.

  11. A modification of the Regional Nutrient Management model (ReNuMa) to identify long-term changes in riverine nitrogen sources

    NASA Astrophysics Data System (ADS)

    Hu, Minpeng; Liu, Yanmei; Wang, Jiahui; Dahlgren, Randy A.; Chen, Dingjiang

    2018-06-01

    Source apportionment is critical for guiding development of efficient watershed nitrogen (N) pollution control measures. The ReNuMa (Regional Nutrient Management) model, a semi-empirical, semi-process-oriented model with modest data requirements, has been widely used for riverine N source apportionment. However, the ReNuMa model contains limitations for addressing long-term N dynamics by ignoring temporal changes in atmospheric N deposition rates and N-leaching lag effects. This work modified the ReNuMa model by revising the source code to allow yearly changes in atmospheric N deposition and incorporation of N-leaching lag effects into N transport processes. The appropriate N-leaching lag time was determined from cross-correlation analysis between annual watershed individual N source inputs and riverine N export. Accuracy of the modified ReNuMa model was demonstrated through analysis of a 31-year water quality record (1980-2010) from the Yongan watershed in eastern China. The revisions considerably improved the accuracy (Nash-Sutcliff coefficient increased by ∼0.2) of the modified ReNuMa model for predicting riverine N loads. The modified model explicitly identified annual and seasonal changes in contributions of various N sources (i.e., point vs. nonpoint source, surface runoff vs. groundwater) to riverine N loads as well as the fate of watershed anthropogenic N inputs. Model results were consistent with previously modeled or observed lag time length as well as changes in riverine chloride and nitrate concentrations during the low-flow regime and available N levels in agricultural soils of this watershed. The modified ReNuMa model is applicable for addressing long-term changes in riverine N sources, providing decision-makers with critical information for guiding watershed N pollution control strategies.

  12. Joint detection of anatomical points on surface meshes and color images for visual registration of 3D dental models

    NASA Astrophysics Data System (ADS)

    Destrez, Raphaël.; Albouy-Kissi, Benjamin; Treuillet, Sylvie; Lucas, Yves

    2015-04-01

    Computer aided planning for orthodontic treatment requires knowing occlusion of separately scanned dental casts. A visual guided registration is conducted starting by extracting corresponding features in both photographs and 3D scans. To achieve this, dental neck and occlusion surface are firstly extracted by image segmentation and 3D curvature analysis. Then, an iterative registration process is conducted during which feature positions are refined, guided by previously found anatomic edges. The occlusal edge image detection is improved by an original algorithm which follows Canny's poorly detected edges using a priori knowledge of tooth shapes. Finally, the influence of feature extraction and position optimization is evaluated in terms of the quality of the induced registration. Best combination of feature detection and optimization leads to a positioning average error of 1.10 mm and 2.03°.

  13. An infrared sky model based on the IRAS point source data

    NASA Technical Reports Server (NTRS)

    Cohen, Martin; Walker, Russell; Wainscoat, Richard; Volk, Kevin; Walker, Helen; Schwartz, Deborah

    1990-01-01

    A detailed model for the infrared point source sky is presented that comprises geometrically and physically realistic representations of the galactic disk, bulge, spheroid, spiral arms, molecular ring, and absolute magnitudes. The model was guided by a parallel Monte Carlo simulation of the Galaxy. The content of the galactic source table constitutes an excellent match to the 12 micrometer luminosity function in the simulation, as well as the luminosity functions at V and K. Models are given for predicting the density of asteroids to be observed, and the diffuse background radiance of the Zodiacal cloud. The model can be used to predict the character of the point source sky expected for observations from future infrared space experiments.

  14. Quality of Widely Available Video Instructional Materials for Point-of-Care Ultrasound-Guided Procedure Training in Internal Medicine.

    PubMed

    Khandelwal, Aditi; Devine, Luke A; Otremba, Mirek

    2017-07-01

    Many instructional materials for point-of-care ultrasound (US)-guided procedures exist; however, their quality is unknown. This study assessed widely available educational videos for point-of-care US-guided procedures relevant to internal medicine: central venous catheterization, thoracentesis, and paracentesis. We searched Ovid MEDLINE, YouTube, and Google to identify videos for point-of-care US-guided paracentesis, thoracentesis, and central venous catheterization. Videos were evaluated with a 5-point scale assessing the global educational value and a checklist based on consensus guidelines for competencies in point-of-care US-guided procedures. For point-of-care US-guided central venous catheterization, 12 videos were found, with an average global educational value score ± SD of 4.5 ± 0.7. Indications to abort the procedure were discussed in only 3 videos. Five videos described the indications and contraindications for performing central venous catheterization. For point-of-care US-guided thoracentesis, 8 videos were identified, with an average global educational value score of 4.0 ± 0.9. Only one video discussed indications to abort the procedure, and 3 videos discussed sterile technique. For point-of-care US-guided paracentesis, 7 videos were included, with an average global educational value score of 4.1 ± 0.9. Only 1 video discussed indications to abort the procedure, and 2 described the location of the inferior epigastric artery. The 27 videos reviewed contained good-quality general instruction. However, we noted a lack of safety-related information in most of the available videos. Further development of resources is required to teach internal medicine trainees skills that focus on the safety of point-of-care US guidance. © 2017 by the American Institute of Ultrasound in Medicine.

  15. Digging deeper into noise. Reply to comment on "Extracting physics of life at the molecular level: A review of single-molecule data analyses"

    NASA Astrophysics Data System (ADS)

    Colomb, Warren; Sarkar, Susanta K.

    2015-06-01

    We would like to thank all the commentators for their constructive comments on our paper. Commentators agree that a proper analysis of noisy single-molecule data is important for extracting meaningful and accurate information about the system. We concur with their views and indeed, motivating an accurate analysis of experimental data is precisely the point of our paper. After a model about the system of interest is constructed based on the experimental single-molecule data, it is very helpful to simulate the model to generate theoretical single-molecule data and analyze exactly the same way. In our experience, such self-consistent approach involving experiments, simulations, and analyses often forces us to revise our model and make experimentally testable predictions. In light of comments from the commentators with different expertise, we would also like to point out that a single model should be able to connect different experimental techniques because the underlying science does not depend on the experimental techniques used. Wohland [1] has made a strong case for fluorescence correlation spectroscopy (FCS) as an important experimental technique to bridge single-molecule and ensemble experiments. FCS is a very powerful technique that can measure ensemble parameters with single-molecule sensitivity. Therefore, it is logical to simulate any proposed model and predict both single-molecule data and FCS data, and confirm with experimental data. Fitting the diffraction-limited point spread function (PSF) of an isolated fluorescent marker to localize a labeled biomolecule is a critical step in many single-molecule tracking experiments. Flyvbjerg et al. [2] have rigorously pointed out some important drawbacks of the prevalent practice of fitting diffraction-limited PSF with 2D Gaussian. As we try to achieve more accurate and precise localization of biomolecules, we need to consider subtle points as mentioned by Flyvbjerg et al. Shepherd [3] has mentioned specific examples of PSF that have been used for localization and has rightly mentioned the importance of detector noise in single-molecule localization. Meroz [4] has pointed out more clearly that the signal itself could be noisy and it is necessary to distinguish the noise of interest from the background noise. Krapf [5] has pointed out different origins of fluctuations in biomolecular systems and commented on their possible Gaussian and non-Gaussian nature. Importance of noise along with the possibility that the noise itself can be the signal of interest has been discussed in our paper [6]. However, Meroz [4] and Krapf [5] have provided specific examples to guide the readers in a better way. Sachs et al. [7] have discussed kinetic analysis in the presence of indistinguishable states and have pointed to the free software for the general kinetic analysis that originated from their research.

  16. Anatomy guided automated SPECT renal seed point estimation

    NASA Astrophysics Data System (ADS)

    Dwivedi, Shekhar; Kumar, Sailendra

    2010-04-01

    Quantification of SPECT(Single Photon Emission Computed Tomography) images can be more accurate if correct segmentation of region of interest (ROI) is achieved. Segmenting ROI from SPECT images is challenging due to poor image resolution. SPECT is utilized to study the kidney function, though the challenge involved is to accurately locate the kidneys and bladder for analysis. This paper presents an automated method for generating seed point location of both kidneys using anatomical location of kidneys and bladder. The motivation for this work is based on the premise that the anatomical location of the bladder relative to the kidneys will not differ much. A model is generated based on manual segmentation of the bladder and both the kidneys on 10 patient datasets (including sum and max images). Centroid is estimated for manually segmented bladder and kidneys. Relatively easier bladder segmentation is followed by feeding bladder centroid coordinates into the model to generate seed point for kidneys. Percentage error observed in centroid coordinates of organs from ground truth to estimated values from our approach are acceptable. Percentage error of approximately 1%, 6% and 2% is observed in X coordinates and approximately 2%, 5% and 8% is observed in Y coordinates of bladder, left kidney and right kidney respectively. Using a regression model and the location of the bladder, the ROI generation for kidneys is facilitated. The model based seed point estimation will enhance the robustness of kidney ROI estimation for noisy cases.

  17. Reliability of Soft Tissue Model Based Implant Surgical Guides; A Methodological Mistake.

    PubMed

    Sabour, Siamak; Dastjerdi, Elahe Vahid

    2012-08-20

    Abstract We were interested to read the paper by Maney P and colleagues published in the July 2012 issue of J Oral Implantol. The authors aimed to assess the reliability of soft tissue model based implant surgical guides reported that the accuracy was evaluated using software. 1 I found the manuscript title of Maney P, et al. incorrect and misleading. Moreover, they reported twenty-two sites (46.81%) were considered accurate (13 of 24 maxillary and 9 of 23 mandibular sites). As the authors point out in their conclusion, Soft tissue models do not always provide sufficient accuracy for implant surgical guide fabrication.Reliability (precision) and validity (accuracy) are two different methodological issues in researches. Sensitivity, specificity, PPV, NPV, likelihood ratio positive (true positive/false negative) and likelihood ratio negative (false positive/ true negative) as well as odds ratio (true results\\false results - preferably more than 50) are among the tests to evaluate the validity (accuracy) of a single test compared to a gold standard.2-4 It is not clear that the reported twenty-two sites (46.81%) which were considered accurate related to which of the above mentioned estimates for validity analysis. Reliability (repeatability or reproducibility) is being assessed by different statistical tests such as Pearson r, least square and paired t.test which all of them are among common mistakes in reliability analysis 5. Briefly, for quantitative variable Intra Class Correlation Coefficient (ICC) and for qualitative variables weighted kappa should be used with caution because kappa has its own limitation too. Regarding reliability or agreement, it is good to know that for computing kappa value, just concordant cells are being considered, whereas discordant cells should also be taking into account in order to reach a correct estimation of agreement (Weighted kappa).2-4 As a take home message, for reliability and validity analysis, appropriate tests should be applied.

  18. Guiding and Modelling Quality Improvement in Higher Education Institutions

    ERIC Educational Resources Information Center

    Little, Daniel

    2015-01-01

    The article considers the process of creating quality improvement in higher education institutions from the point of view of current organisational theory and social-science modelling techniques. The author considers the higher education institution as a functioning complex of rules, norms and other organisational features and reviews the social…

  19. Precision of guided scanning procedures for full-arch digital impressions in vivo.

    PubMed

    Zimmermann, Moritz; Koller, Christina; Rumetsch, Moritz; Ender, Andreas; Mehl, Albert

    2017-11-01

    System-specific scanning strategies have been shown to influence the accuracy of full-arch digital impressions. Special guided scanning procedures have been implemented for specific intraoral scanning systems with special regard to the digital orthodontic workflow. The aim of this study was to evaluate the precision of guided scanning procedures compared to conventional impression techniques in vivo. Two intraoral scanning systems with implemented full-arch guided scanning procedures (Cerec Omnicam Ortho; Ormco Lythos) were included along with one conventional impression technique with irreversible hydrocolloid material (alginate). Full-arch impressions were taken three times each from 5 participants (n = 15). Impressions were then compared within the test groups using a point-to-surface distance method after best-fit model matching (OraCheck). Precision was calculated using the (90-10%)/2 quantile and statistical analysis with one-way repeated measures ANOVA and post hoc Bonferroni test was performed. The conventional impression technique with alginate showed the lowest precision for full-arch impressions with 162.2 ± 71.3 µm. Both guided scanning procedures performed statistically significantly better than the conventional impression technique (p < 0.05). Mean values for group Cerec Omnicam Ortho were 74.5 ± 39.2 µm and for group Ormco Lythos 91.4 ± 48.8 µm. The in vivo precision of guided scanning procedures exceeds conventional impression techniques with the irreversible hydrocolloid material alginate. Guided scanning procedures may be highly promising for clinical applications, especially for digital orthodontic workflows.

  20. Conceptualising a model to guide nursing and midwifery in the community guided by an evidence review.

    PubMed

    Leahy-Warren, Patricia; Mulcahy, Helen; Benefield, Lazelle; Bradley, Colin; Coffey, Alice; Donohoe, Ann; Fitzgerald, Serena; Frawley, Tim; Healy, Elizabeth; Healy, Maria; Kelly, Marcella; McCarthy, Bernard; McLoughlin, Kathleen; Meagher, Catherine; O'Connell, Rhona; O'Mahony, Aoife; Paul, Gillian; Phelan, Amanda; Stokes, Diarmuid; Walsh, Jessica; Savage, Eileen

    2017-01-01

    Successful models of nursing and midwifery in the community delivering healthcare throughout the lifespan and across a health and illness continuum are limited, yet necessary to guide global health services. Primary and community health services are the typical points of access for most people and the location where most care is delivered. The scope of primary healthcare is complex and multifaceted and therefore requires a practice framework with sound conceptual and theoretical underpinnings. The aim of this paper is to present a conceptual model informed by a scoping evidence review of the literature. A scoping evidence review of the literature was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) statement. Databases included CINAHL, MEDLINE, PsycINFO and SocINDEX using the EBSCO platform and the Cochrane Library using the keywords: model, nursing, midwifery, community, primary care. Grey literature for selected countries was searched using the Google 'advanced' search interface. Data extraction and quality appraisal for both empirical and grey literature were conducted independently by two reviewers. From 127 empirical and 24 non-empirical papers, data extraction parameters, in addition to the usual methodological features, included: the nature of nursing and midwifery; the population group; interventions and main outcomes; components of effective nursing and midwifery outcomes. The evidence was categorised into six broad areas and subsequently synthesised into four themes. These were not mutually exclusive: (1) Integrated and Collaborative Care; (2) Organisation and Delivery of Nursing and Midwifery Care in the Community; (3) Adjuncts to Nursing Care and (4) Overarching Conceptual Model. It is the latter theme that is the focus of this paper. In essence, the model depicts a person/client on a lifespan and preventative-curative trajectory. The health related needs of the client, commensurate with their point position, relative to both trajectories, determines the nurse or midwife intervention. Consequently, it is this need, that determines the discipline or speciality of the nurse or midwife with the most appropriate competencies. Use of a conceptual model of nursing and midwifery to inform decision-making in primary/community based care ensures clinical outcomes are meaningful and more sustainable. Operationalising this model for nursing and midwifery in the community demands strong leadership and effective clinical governance.

  1. A solution to the online guidance problem for targeted reaches: proportional rate control using relative disparity tau.

    PubMed

    Anderson, Joe; Bingham, Geoffrey P

    2010-09-01

    We provide a solution to a major problem in visually guided reaching. Research has shown that binocular vision plays an important role in the online visual guidance of reaching, but the visual information and strategy used to guide a reach remains unknown. We propose a new theory of visual guidance of reaching including a new information variable, tau(alpha) (relative disparity tau), and a novel control strategy that allows actors to guide their reach trajectories visually by maintaining a constant proportion between tau(alpha) and its rate of change. The dynamical model couples the information to the reaching movement to generate trajectories characteristic of human reaching. We tested the theory in two experiments in which participants reached under conditions of darkness to guide a visible point either on a sliding apparatus or on their finger to a point-light target in depth. Slider apparatus controlled for a simple mapping from visual to proprioceptive space. When reaching with their finger, participants were forced, by perturbation of visual information used for feedforward control, to use online control with only binocular disparity-based information for guidance. Statistical analyses of trajectories strongly supported the theory. Simulations of the model were compared statistically to actual reaching trajectories. The results supported the theory, showing that tau(alpha) provides a source of information for the control of visually guided reaching and that participants use this information in a proportional rate control strategy.

  2. Greedy Sampling and Incremental Surrogate Model-Based Tailoring of Aeroservoelastic Model Database for Flexible Aircraft

    NASA Technical Reports Server (NTRS)

    Wang, Yi; Pant, Kapil; Brenner, Martin J.; Ouellette, Jeffrey A.

    2018-01-01

    This paper presents a data analysis and modeling framework to tailor and develop linear parameter-varying (LPV) aeroservoelastic (ASE) model database for flexible aircrafts in broad 2D flight parameter space. The Kriging surrogate model is constructed using ASE models at a fraction of grid points within the original model database, and then the ASE model at any flight condition can be obtained simply through surrogate model interpolation. The greedy sampling algorithm is developed to select the next sample point that carries the worst relative error between the surrogate model prediction and the benchmark model in the frequency domain among all input-output channels. The process is iterated to incrementally improve surrogate model accuracy till a pre-determined tolerance or iteration budget is met. The methodology is applied to the ASE model database of a flexible aircraft currently being tested at NASA/AFRC for flutter suppression and gust load alleviation. Our studies indicate that the proposed method can reduce the number of models in the original database by 67%. Even so the ASE models obtained through Kriging interpolation match the model in the original database constructed directly from the physics-based tool with the worst relative error far below 1%. The interpolated ASE model exhibits continuously-varying gains along a set of prescribed flight conditions. More importantly, the selected grid points are distributed non-uniformly in the parameter space, a) capturing the distinctly different dynamic behavior and its dependence on flight parameters, and b) reiterating the need and utility for adaptive space sampling techniques for ASE model database compaction. The present framework is directly extendible to high-dimensional flight parameter space, and can be used to guide the ASE model development, model order reduction, robust control synthesis and novel vehicle design of flexible aircraft.

  3. Mode perturbation method for optimal guided wave mode and frequency selection.

    PubMed

    Philtron, J H; Rose, J L

    2014-09-01

    With a thorough understanding of guided wave mechanics, researchers can predict which guided wave modes will have a high probability of success in a particular nondestructive evaluation application. However, work continues to find optimal mode and frequency selection for a given application. This "optimal" mode could give the highest sensitivity to defects or the greatest penetration power, increasing inspection efficiency. Since material properties used for modeling work may be estimates, in many cases guided wave mode and frequency selection can be adjusted for increased inspection efficiency in the field. In this paper, a novel mode and frequency perturbation method is described and used to identify optimal mode points based on quantifiable wave characteristics. The technique uses an ultrasonic phased array comb transducer to sweep in phase velocity and frequency space. It is demonstrated using guided interface waves for bond evaluation. After searching nearby mode points, an optimal mode and frequency can be selected which has the highest sensitivity to a defect, or gives the greatest penetration power. The optimal mode choice for a given application depends on the requirements of the inspection. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Computational Model for Impact-Resisting Critical Thickness of High-Speed Machine Outer Protective Plate

    NASA Astrophysics Data System (ADS)

    Wu, Huaying; Wang, Li Zhong; Wang, Yantao; Yuan, Xiaolei

    2018-05-01

    The blade or surface grinding blade of the hypervelocity grinding wheel may be damaged due to too high rotation rate of the spindle of the machine and then fly out. Its speed as a projectile may severely endanger the field persons. Critical thickness model of the protective plate of the high-speed machine is studied in this paper. For easy analysis, the shapes of the possible impact objects flying from the high-speed machine are simplified as sharp-nose model, ball-nose model and flat-nose model. Whose front ending shape to represent point, line and surface contacting. Impact analysis based on J-C model is performed for the low-carbon steel plate with different thicknesses in this paper. One critical thickness computational model for the protective plate of high-speed machine is established according to the damage characteristics of the thin plate to get relation among plate thickness and mass, shape and size and impact speed of impact object. The air cannon is used for impact test. The model accuracy is validated. This model can guide identification of the thickness of single-layer outer protective plate of a high-speed machine.

  5. Beach Profile Analysis System (BPAS). Volume III. BPAS User’s Guide: Analysis Module SURVY1.

    DTIC Science & Technology

    1982-06-01

    extrapolated using the two seawardmost points. Before computing volume changes, common bonds are established relative to the landward and seawsrd extent...Cyber 176 or equivalent computer. Such features include the 10- character, 60-bit word size, the FORTRAN- callable sort routine (interfacing with the NOS

  6. Beach Profile Analysis Systems (BPAS). Volume VI. BPAS User’s Guide: Analysis Module VOLCTR.

    DTIC Science & Technology

    1982-06-01

    the two seawardmost points. Before computing volume changes, common bonds are established relative to the landward and seaward extent of the surveys on...bit word size, the FORTRAN- callable sort routine (interfacing with the NOS or NOSME operating system SORTMRG utility), and the utility subroutines and

  7. Beach Profile Analysis System (BPAS). Volume IV. BPAS User’s Guide: Analysis Module SURVY2.

    DTIC Science & Technology

    1982-06-01

    feet NSL), the shoreline position can be extrapolated using the two sawardmost points. Before computing volume changes, comon bonds are established...computer. Such features include the 10- character, 60-bit word size, the FORTRAN- callable sort routine (interfacing with the NOS or NOS/BE operating

  8. Confirmatory factor analysis of teaching and learning guiding principles instrument among teacher educators in higher education institutions

    NASA Astrophysics Data System (ADS)

    Masuwai, Azwani; Tajudin, Nor'ain Mohd; Saad, Noor Shah

    2017-05-01

    The purpose of this study is to develop and establish the validity and reliability of an instrument to generate teaching and learning guiding principles using Teaching and Learning Guiding Principles Instrument (TLGPI). Participants consisted of 171 Malaysian teacher educators. It is an essential instrument to reflect in generating the teaching and learning guiding principles in higher education level in Malaysia. Confirmatory Factor Analysis has validated all 19 items of TLGPI whereby all items indicated high reliability and internal consistency. A Confirmatory Factor Analysis also confirmed that a single factor model was used to generate teaching and learning guiding principles.

  9. A Comparative Analysis of Speed Profile Models for Ankle Pointing Movements: Evidence that Lower and Upper Extremity Discrete Movements are Controlled by a Single Invariant Strategy

    PubMed Central

    Michmizos, Konstantinos P.; Vaisman, Lev; Krebs, Hermano Igo

    2014-01-01

    Little is known about whether our knowledge of how the central nervous system controls the upper extremities (UE), can generalize, and to what extent to the lower limbs. Our continuous efforts to design the ideal adaptive robotic therapy for the lower limbs of stroke patients and children with cerebral palsy highlighted the importance of analyzing and modeling the kinematics of the lower limbs, in general, and those of the ankle joints, in particular. We recruited 15 young healthy adults that performed in total 1,386 visually evoked, visually guided, and target-directed discrete pointing movements with their ankle in dorsal–plantar and inversion–eversion directions. Using a non-linear, least-squares error-minimization procedure, we estimated the parameters for 19 models, which were initially designed to capture the dynamics of upper limb movements of various complexity. We validated our models based on their ability to reconstruct the experimental data. Our results suggest a remarkable similarity between the top-performing models that described the speed profiles of ankle pointing movements and the ones previously found for the UE both during arm reaching and wrist pointing movements. Among the top performers were the support-bounded lognormal and the beta models that have a neurophysiological basis and have been successfully used in upper extremity studies with normal subjects and patients. Our findings suggest that the same model can be applied to different “human” hardware, perhaps revealing a key invariant in human motor control. These findings have a great potential to enhance our rehabilitation efforts in any population with lower extremity deficits by, for example, assessing the level of motor impairment and improvement as well as informing the design of control algorithms for therapeutic ankle robots. PMID:25505881

  10. Expert system development for commonality analysis in space programs

    NASA Technical Reports Server (NTRS)

    Yeager, Dorian P.

    1987-01-01

    This report is a combination of foundational mathematics and software design. A mathematical model of the Commonality Analysis problem was developed and some important properties discovered. The complexity of the problem is described herein and techniques, both deterministic and heuristic, for reducing that complexity are presented. Weaknesses are pointed out in the existing software (System Commonality Analysis Tool) and several improvements are recommended. It is recommended that: (1) an expert system for guiding the design of new databases be developed; (2) a distributed knowledge base be created and maintained for the purpose of encoding the commonality relationships between design items in commonality databases; (3) a software module be produced which automatically generates commonality alternative sets from commonality databases using the knowledge associated with those databases; and (4) a more complete commonality analysis module be written which is capable of generating any type of feasible solution.

  11. Project for a Contrastive Analysis of the Sound Systems, Grammars and Lexicons of Serbo-Croatian and English. Phase 1: Phonology and Grammar. Final Report.

    ERIC Educational Resources Information Center

    Filipovic, Rudolf

    This project provides descriptions of some points of contrast between Serbo-Croatian and English in the fields of phonology, grammar, and lexicon. The project concentrated particularly on the points showing difficulties for the English-speaking learner of Serbo-Croatian, thus forming the basis for development of teaching materials and guides for…

  12. Linear Mixed Models: Gum and Beyond

    NASA Astrophysics Data System (ADS)

    Arendacká, Barbora; Täubner, Angelika; Eichstädt, Sascha; Bruns, Thomas; Elster, Clemens

    2014-04-01

    In Annex H.5, the Guide to the Evaluation of Uncertainty in Measurement (GUM) [1] recognizes the necessity to analyze certain types of experiments by applying random effects ANOVA models. These belong to the more general family of linear mixed models that we focus on in the current paper. Extending the short introduction provided by the GUM, our aim is to show that the more general, linear mixed models cover a wider range of situations occurring in practice and can be beneficial when employed in data analysis of long-term repeated experiments. Namely, we point out their potential as an aid in establishing an uncertainty budget and as means for gaining more insight into the measurement process. We also comment on computational issues and to make the explanations less abstract, we illustrate all the concepts with the help of a measurement campaign conducted in order to challenge the uncertainty budget in calibration of accelerometers.

  13. Analysis of Uncertainty in a Middle-Cost Device for 3D Measurements in BIM Perspective

    PubMed Central

    Sánchez, Alonso; Naranjo, José-Manuel; Jiménez, Antonio; González, Alfonso

    2016-01-01

    Medium-cost devices equipped with sensors are being developed to get 3D measurements. Some allow for generating geometric models and point clouds. Nevertheless, the accuracy of these measurements should be evaluated, taking into account the requirements of the Building Information Model (BIM). This paper analyzes the uncertainty in outdoor/indoor three-dimensional coordinate measures and point clouds (using Spherical Accuracy Standard (SAS) methods) for Eyes Map, a medium-cost tablet manufactured by e-Capture Research & Development Company, Mérida, Spain. To achieve it, in outdoor tests, by means of this device, the coordinates of targets were measured from 1 to 6 m and cloud points were obtained. Subsequently, these were compared to the coordinates of the same targets measured by a Total Station. The Euclidean average distance error was 0.005–0.027 m for measurements by Photogrammetry and 0.013–0.021 m for the point clouds. All of them satisfy the tolerance for point cloud acquisition (0.051 m) according to the BIM Guide for 3D Imaging (General Services Administration); similar results are obtained in the indoor tests, with values of 0.022 m. In this paper, we establish the optimal distances for the observations in both, Photogrammetry and 3D Photomodeling modes (outdoor) and point out some working conditions to avoid in indoor environments. Finally, the authors discuss some recommendations for improving the performance and working methods of the device. PMID:27669245

  14. Performance/price estimates for cortex-scale hardware: a design space exploration.

    PubMed

    Zaveri, Mazad S; Hammerstrom, Dan

    2011-04-01

    In this paper, we revisit the concept of virtualization. Virtualization is useful for understanding and investigating the performance/price and other trade-offs related to the hardware design space. Moreover, it is perhaps the most important aspect of a hardware design space exploration. Such a design space exploration is a necessary part of the study of hardware architectures for large-scale computational models for intelligent computing, including AI, Bayesian, bio-inspired and neural models. A methodical exploration is needed to identify potentially interesting regions in the design space, and to assess the relative performance/price points of these implementations. As an example, in this paper we investigate the performance/price of (digital and mixed-signal) CMOS and hypothetical CMOL (nanogrid) technology based hardware implementations of human cortex-scale spiking neural systems. Through this analysis, and the resulting performance/price points, we demonstrate, in general, the importance of virtualization, and of doing these kinds of design space explorations. The specific results suggest that hybrid nanotechnology such as CMOL is a promising candidate to implement very large-scale spiking neural systems, providing a more efficient utilization of the density and storage benefits of emerging nano-scale technologies. In general, we believe that the study of such hypothetical designs/architectures will guide the neuromorphic hardware community towards building large-scale systems, and help guide research trends in intelligent computing, and computer engineering. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. Mirror neurons and imitation: a computationally guided review.

    PubMed

    Oztop, Erhan; Kawato, Mitsuo; Arbib, Michael

    2006-04-01

    Neurophysiology reveals the properties of individual mirror neurons in the macaque while brain imaging reveals the presence of 'mirror systems' (not individual neurons) in the human. Current conceptual models attribute high level functions such as action understanding, imitation, and language to mirror neurons. However, only the first of these three functions is well-developed in monkeys. We thus distinguish current opinions (conceptual models) on mirror neuron function from more detailed computational models. We assess the strengths and weaknesses of current computational models in addressing the data and speculations on mirror neurons (macaque) and mirror systems (human). In particular, our mirror neuron system (MNS), mental state inference (MSI) and modular selection and identification for control (MOSAIC) models are analyzed in more detail. Conceptual models often overlook the computational requirements for posited functions, while too many computational models adopt the erroneous hypothesis that mirror neurons are interchangeable with imitation ability. Our meta-analysis underlines the gap between conceptual and computational models and points out the research effort required from both sides to reduce this gap.

  16. Phase I/II prospective trial of cancer-specific imaging using ultrasound spectrum analysis tissue-type imaging to guide dose-painting prostate brachytherapy.

    PubMed

    Ennis, Ronald D; Quinn, S Aidan; Trichter, Frieda; Ryemon, Shannon; Jain, Anudh; Saigal, Kunal; Chandrashekhar, Sarayu; Romas, Nicholas A; Feleppa, Ernest J

    2015-01-01

    To assess the technical feasibility, toxicity, dosimetry, and preliminary efficacy of dose-painting brachytherapy guided by ultrasound spectrum analysis tissue-type imaging (TTI) in low-risk, localized prostate cancer. Fourteen men with prostate cancer who were candidates for brachytherapy as sole treatment were prospectively enrolled. Treatment planning goal was to escalate the tumor dose to 200% with a modest de-escalation of dose to remaining prostate compared with our standard. Primary end points included technical feasibility of TTI-guided brachytherapy and equivalent or better toxicity compared with standard brachytherapy. Secondary end points included dose escalation to tumor regions and de-escalated dose to nontumor regions on the preimplant plan, negative prostate biopsy at 2 years, and freedom from biochemical failure. Thirteen of fourteen men successfully completed the TTI-guided brachytherapy procedure for a feasibility rate of 93%. A software malfunction resulted in switching one patient from TTI-guided to standard brachytherapy. An average of 2.7 foci per patient was demonstrated and treated with an escalated dose. Dosimetric goals on preplan were achieved. One patient expired from unrelated causes 65 days after brachytherapy. Toxicity was at least as low as standard brachytherapy. Two-year prostate biopsies were obtained from six men; five (83%) were definitively negative, one showed evidence of disease with treatment effect, and none were positive. No patients experienced biochemical recurrence after a median followup of 31.5 (24-52) months. We have demonstrated that TTI-guided dose-painting prostate brachytherapy is technically feasible and results in clinical outcomes that are encouraging in terms of low toxicity and successful biochemical disease control. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  17. Progress with the lick adaptive optics system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gavel, D T; Olivier, S S; Bauman, B

    2000-03-01

    Progress and results of observations with the Lick Observatory Laser Guide Star Adaptive Optics System are presented. This system is optimized for diffraction-limited imaging in the near infrared, 1-2 micron wavelength bands. We describe our development efforts in a number of component areas including, a redesign of the optical bench layout, the commissioning of a new infrared science camera, and improvements to the software and user interface. There is also an ongoing effort to characterize the system performance with both natural and laser guide stars and to fold this data into a refined system model. Such a model can bemore » used to help plan future observations, for example, predicting the point-spread function as a function of seeing and guide star magnitude.« less

  18. Advanced Diagnostic and Prognostic Testbed (ADAPT) Testability Analysis Report

    NASA Technical Reports Server (NTRS)

    Ossenfort, John

    2008-01-01

    As system designs become more complex, determining the best locations to add sensors and test points for the purpose of testing and monitoring these designs becomes more difficult. Not only must the designer take into consideration all real and potential faults of the system, he or she must also find efficient ways of detecting and isolating those faults. Because sensors and cabling take up valuable space and weight on a system, and given constraints on bandwidth and power, it is even more difficult to add sensors into these complex designs after the design has been completed. As a result, a number of software tools have been developed to assist the system designer in proper placement of these sensors during the system design phase of a project. One of the key functions provided by many of these software programs is a testability analysis of the system essentially an evaluation of how observable the system behavior is using available tests. During the design phase, testability metrics can help guide the designer in improving the inherent testability of the design. This may include adding, removing, or modifying tests; breaking up feedback loops, or changing the system to reduce fault propagation. Given a set of test requirements, the analysis can also help to verify that the system will meet those requirements. Of course, a testability analysis requires that a software model of the physical system is available. For the analysis to be most effective in guiding system design, this model should ideally be constructed in parallel with these efforts. The purpose of this paper is to present the final testability results of the Advanced Diagnostic and Prognostic Testbed (ADAPT) after the system model was completed. The tool chosen to build the model and to perform the testability analysis with is the Testability Engineering and Maintenance System Designer (TEAMS-Designer). The TEAMS toolset is intended to be a solution to span all phases of the system, from design and development through health management and maintenance. TEAMS-Designer is the model-building and testability analysis software in that suite.

  19. Reaction Wheel Disturbance Model Extraction Software - RWDMES

    NASA Technical Reports Server (NTRS)

    Blaurock, Carl

    2009-01-01

    The RWDMES is a tool for modeling the disturbances imparted on spacecraft by spinning reaction wheels. Reaction wheels are usually the largest disturbance source on a precision pointing spacecraft, and can be the dominating source of pointing error. Accurate knowledge of the disturbance environment is critical to accurate prediction of the pointing performance. In the past, it has been difficult to extract an accurate wheel disturbance model since the forcing mechanisms are difficult to model physically, and the forcing amplitudes are filtered by the dynamics of the reaction wheel. RWDMES captures the wheel-induced disturbances using a hybrid physical/empirical model that is extracted directly from measured forcing data. The empirical models capture the tonal forces that occur at harmonics of the spin rate, and the broadband forces that arise from random effects. The empirical forcing functions are filtered by a physical model of the wheel structure that includes spin-rate-dependent moments (gyroscopic terms). The resulting hybrid model creates a highly accurate prediction of wheel-induced forces. It accounts for variation in disturbance frequency, as well as the shifts in structural amplification by the whirl modes, as the spin rate changes. This software provides a point-and-click environment for producing accurate models with minimal user effort. Where conventional approaches may take weeks to produce a model of variable quality, RWDMES can create a demonstrably high accuracy model in two hours. The software consists of a graphical user interface (GUI) that enables the user to specify all analysis parameters, to evaluate analysis results and to iteratively refine the model. Underlying algorithms automatically extract disturbance harmonics, initialize and tune harmonic models, and initialize and tune broadband noise models. The component steps are described in the RWDMES user s guide and include: converting time domain data to waterfall PSDs (power spectral densities); converting PSDs to order analysis data; extracting harmonics; initializing and simultaneously tuning a harmonic model and a wheel structural model; initializing and tuning a broadband model; and verifying the harmonic/broadband/structural model against the measurement data. Functional operation is through a MATLAB GUI that loads test data, performs the various analyses, plots evaluation data for assessment and refinement of analysis parameters, and exports the data to documentation or downstream analysis code. The harmonic models are defined as specified functions of frequency, typically speed-squared. The reaction wheel structural model is realized as mass, damping, and stiffness matrices (typically from a finite element analysis package) with the addition of a gyroscopic forcing matrix. The broadband noise model is realized as a set of speed-dependent filters. The tuning of the combined model is performed using nonlinear least squares techniques. RWDMES is implemented as a MATLAB toolbox comprising the Fit Manager for performing the model extraction, Data Manager for managing input data and output models, the Gyro Manager for modifying wheel structural models, and the Harmonic Editor for evaluating and tuning harmonic models. This software was validated using data from Goodrich E wheels, and from GSFC Lunar Reconnaissance Orbiter (LRO) wheels. The validation testing proved that RWDMES has the capability to extract accurate disturbance models from flight reaction wheels with minimal user effort.

  20. FHWA traffic noise model, version 1.0 : user's guide

    DOT National Transportation Integrated Search

    1998-01-01

    This User's Guide is for the Federal Highway Administration's Traffic Noise Model (FHWA TNM), Version 1.0 -- the FHWAs computer program for highway traffic noise prediction and analysis. Two companion reports, a Technical Manual and a data repor...

  1. Surrogate-based Analysis and Optimization

    NASA Technical Reports Server (NTRS)

    Queipo, Nestor V.; Haftka, Raphael T.; Shyy, Wei; Goel, Tushar; Vaidyanathan, Raj; Tucker, P. Kevin

    2005-01-01

    A major challenge to the successful full-scale development of modem aerospace systems is to address competing objectives such as improved performance, reduced costs, and enhanced safety. Accurate, high-fidelity models are typically time consuming and computationally expensive. Furthermore, informed decisions should be made with an understanding of the impact (global sensitivity) of the design variables on the different objectives. In this context, the so-called surrogate-based approach for analysis and optimization can play a very valuable role. The surrogates are constructed using data drawn from high-fidelity models, and provide fast approximations of the objectives and constraints at new design points, thereby making sensitivity and optimization studies feasible. This paper provides a comprehensive discussion of the fundamental issues that arise in surrogate-based analysis and optimization (SBAO), highlighting concepts, methods, techniques, as well as practical implications. The issues addressed include the selection of the loss function and regularization criteria for constructing the surrogates, design of experiments, surrogate selection and construction, sensitivity analysis, convergence, and optimization. The multi-objective optimal design of a liquid rocket injector is presented to highlight the state of the art and to help guide future efforts.

  2. Upfront Genotyping of DPYD*2A to Individualize Fluoropyrimidine Therapy: A Safety and Cost Analysis.

    PubMed

    Deenen, Maarten J; Meulendijks, Didier; Cats, Annemieke; Sechterberger, Marjolein K; Severens, Johan L; Boot, Henk; Smits, Paul H; Rosing, Hilde; Mandigers, Caroline M P W; Soesan, Marcel; Beijnen, Jos H; Schellens, Jan H M

    2016-01-20

    Fluoropyrimidines are frequently prescribed anticancer drugs. A polymorphism in the fluoropyrimidine metabolizing enzyme dihydropyrimidine dehydrogenase (DPD; ie, DPYD*2A) is strongly associated with fluoropyrimidine-induced severe and life-threatening toxicity. This study determined the feasibility, safety, and cost of DPYD*2A genotype-guided dosing. Patients intended to be treated with fluoropyrimidine-based chemotherapy were prospectively genotyped for DPYD*2A before start of therapy. Variant allele carriers received an initial dose reduction of ≥ 50% followed by dose titration based on tolerance. Toxicity was the primary end point and was compared with historical controls (ie, DPYD*2A variant allele carriers receiving standard dose described in literature) and with DPYD*2A wild-type patients treated with the standard dose in this study. Secondary end points included a model-based cost analysis, as well as pharmacokinetic and DPD enzyme activity analyses. A total of 2,038 patients were prospectively screened for DPYD*2A, of whom 22 (1.1%) were heterozygous polymorphic. DPYD*2A variant allele carriers were treated with a median dose-intensity of 48% (range, 17% to 91%). The risk of grade ≥ 3 toxicity was thereby significantly reduced from 73% (95% CI, 58% to 85%) in historical controls (n = 48) to 28% (95% CI, 10% to 53%) by genotype-guided dosing (P < .001); drug-induced death was reduced from 10% to 0%. Adequate treatment of genotype-guided dosing was further demonstrated by a similar incidence of grade ≥ 3 toxicity compared with wild-type patients receiving the standard dose (23%; P = .64) and by similar systemic fluorouracil (active drug) exposure. Furthermore, average total treatment cost per patient was lower for screening (€2,772 [$3,767]) than for nonscreening (€2,817 [$3,828]), outweighing screening costs. DPYD*2A is strongly associated with fluoropyrimidine-induced severe and life-threatening toxicity. DPYD*2A genotype-guided dosing results in adequate systemic drug exposure and significantly improves safety of fluoropyrimidine therapy for the individual patient. On a population level, upfront genotyping seemed cost saving. © 2015 by American Society of Clinical Oncology.

  3. Ultrasound- versus Palpation-Guided Injection of Corticosteroid for Plantar Fasciitis: A Meta-Analysis

    PubMed Central

    Yu, Aixi; Qi, Baiwen

    2014-01-01

    Background It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis. Methods Databases (MEDLINE, Cochrane library and EMBASE) and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs) comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB) tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS), tenderness threshold (TT), heel tenderness index (HTI), response rate, plantar fascia thickness (PFT), hypoechogenicity and heel pad thickness (HPT). The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was used to assess the quality of evidence. Results Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI. Conclusion Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research. PMID:24658102

  4. Molecular modeling of ligand-receptor interactions in the OR5 olfactory receptor.

    PubMed

    Singer, M S; Shepherd, G M

    1994-06-02

    Olfactory receptors belong to the superfamily of seven transmembrane domain, G protein-coupled receptors. In order to begin analysis of mechanisms of receptor activation, a computer model of the OR5 olfactory receptor has been constructed and compared with other members of this superfamily. We have tested docking of the odor molecule lyral, which is known to activate the OR5 receptor. The results point to specific ligand-binding residues on helices III through VII that form a binding pocket in the receptor. Some of these residues occupy sequence positions identical to ligand-binding residues conserved among other superfamily members. The results provide new insights into possible molecular mechanisms of odor recognition and suggest hypotheses to guide future experimental studies using site-directed mutagenesis.

  5. Finite element analysis of electromagnetic propagation in an absorbing wave guide

    NASA Technical Reports Server (NTRS)

    Baumeister, Kenneth J.

    1986-01-01

    Wave guides play a significant role in microwave space communication systems. The attenuation per unit length of the guide depends on its construction and design frequency range. A finite element Galerkin formulation has been developed to study TM electromagnetic propagation in complex two-dimensional absorbing wave guides. The analysis models the electromagnetic absorptive characteristics of a general wave guide which could be used to determine wall losses or simulate resistive terminations fitted into the ends of a guide. It is believed that the general conclusions drawn by using this simpler two-dimensional geometry will be fundamentally the same for other geometries.

  6. User's Guide for RESRAD-OFFSITE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gnanapragasam, E.; Yu, C.

    2015-04-01

    The RESRAD-OFFSITE code can be used to model the radiological dose or risk to an offsite receptor. This User’s Guide for RESRAD-OFFSITE Version 3.1 is an update of the User’s Guide for RESRAD-OFFSITE Version 2 contained in the Appendix A of the User’s Manual for RESRAD-OFFSITE Version 2 (ANL/EVS/TM/07-1, DOE/HS-0005, NUREG/CR-6937). This user’s guide presents the basic information necessary to use Version 3.1 of the code. It also points to the help file and other documents that provide more detailed information about the inputs, the input forms and features/tools in the code; two of the features (overriding the source termmore » and computing area factors) are discussed in the appendices to this guide. Section 2 describes how to download and install the code and then verify the installation of the code. Section 3 shows ways to navigate through the input screens to simulate various exposure scenarios and to view the results in graphics and text reports. Section 4 has screen shots of each input form in the code and provides basic information about each parameter to increase the user’s understanding of the code. Section 5 outlines the contents of all the text reports and the graphical output. It also describes the commands in the two output viewers. Section 6 deals with the probabilistic and sensitivity analysis tools available in the code. Section 7 details the various ways of obtaining help in the code.« less

  7. Structural and mechanistic insights into human splicing factor SF3b complex derived using an integrated approach guided by the cryo-EM density maps

    PubMed Central

    Rakesh, Ramachandran; Joseph, Agnel Praveen; Bhaskara, Ramachandra M.; Srinivasan, Narayanaswamy

    2016-01-01

    ABSTRACT Pre-mRNA splicing in eukaryotes is performed by the spliceosome, a highly complex macromolecular machine. SF3b is a multi-protein complex which recognizes the branch point adenosine of pre-mRNA as part of a larger U2 snRNP or U11/U12 di-snRNP in the dynamic spliceosome machinery. Although a cryo-EM map is available for human SF3b complex, the structure and relative spatial arrangement of all components in the complex are not yet known. We have recognized folds of domains in various proteins in the assembly and generated comparative models. Using an integrative approach involving structural and other experimental data, guided by the available cryo-EM density map, we deciphered a pseudo-atomic model of the closed form of SF3b which is found to be a “fuzzy complex” with highly flexible components and multiplicity of folds. Further, the model provides structural information for 5 proteins (SF3b10, SF3b155, SF3b145, SF3b130 and SF3b14b) and localization information for 4 proteins (SF3b10, SF3b145, SF3b130 and SF3b14b) in the assembly for the first time. Integration of this model with the available U11/U12 di-snRNP cryo-EM map enabled elucidation of an open form. This now provides new insights on the mechanistic features involved in the transition between closed and open forms pivoted by a hinge region in the SF3b155 protein that also harbors cancer causing mutations. Moreover, the open form guided model of the 5′ end of U12 snRNA, which includes the branch point duplex, shows that the architecture of SF3b acts as a scaffold for U12 snRNA: pre-mRNA branch point duplex formation with potential implications for branch point adenosine recognition fidelity. PMID:27618338

  8. Displacement potential solution of a guided deep beam of composite materials under symmetric three-point bending

    NASA Astrophysics Data System (ADS)

    Rahman, M. Muzibur; Ahmad, S. Reaz

    2017-12-01

    An analytical investigation of elastic fields for a guided deep beam of orthotropic composite material having three point symmetric bending is carried out using displacement potential boundary modeling approach. Here, the formulation is developed as a single function of space variables defined in terms of displacement components, which has to satisfy the mixed type of boundary conditions. The relevant displacement and stress components are derived into infinite series using Fourier integral along with suitable polynomials coincided with boundary conditions. The results are presented mainly in the form of graphs and verified with finite element solutions using ANSYS. This study shows that the analytical and numerical solutions are in good agreement and thus enhances reliability of the displacement potential approach.

  9. Concept mapping as an approach for expert-guided model building: The example of health literacy.

    PubMed

    Soellner, Renate; Lenartz, Norbert; Rudinger, Georg

    2017-02-01

    Concept mapping served as the starting point for the aim of capturing the comprehensive structure of the construct of 'health literacy.' Ideas about health literacy were generated by 99 experts and resulted in 105 statements that were subsequently organized by 27 experts in an unstructured card sorting. Multidimensional scaling was applied to the sorting data and a two and three-dimensional solution was computed. The three dimensional solution was used in subsequent cluster analysis and resulted in a concept map of nine "clusters": (1) self-regulation, (2) self-perception, (3) proactive approach to health, (4) basic literacy and numeracy skills, (5) information appraisal, (6) information search, (7) health care system knowledge and acting, (8) communication and cooperation, and (9) beneficial personality traits. Subsequently, this concept map served as a starting point for developing a "qualitative" structural model of health literacy and a questionnaire for the measurement of health literacy. On the basis of questionnaire data, a "quantitative" structural model was created by first applying exploratory factor analyses (EFA) and then cross-validating the model with confirmatory factor analyses (CFA). Concept mapping proved to be a highly valuable tool for the process of model building up to translational research in the "real world". Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Time Reversal Methods for Structural Health Monitoring of Metallic Structures Using Guided Waves

    DTIC Science & Technology

    2011-09-01

    measure elastic properties of thin isotropic materials and laminated composite plates. Two types of waves propagate a symmetric wave and antisymmetric...compare it to the original signal. In this time reversal procedure wave propagation from point-A to point-B and can be modeled as a convolution ...where * is the convolution operator and transducer transmit and receive transfer function are neglected for simplification. In the frequency

  11. A comparison of individualized treatment guided by VeriStrat with standard of care treatment strategies in patients receiving second-line treatment for advanced non-small cell lung cancer: A cost-utility analysis.

    PubMed

    Nelson, Richard E; Stenehjem, David; Akerley, Wallace

    2013-12-01

    Two therapies are appropriate as 2nd-line treatment of non-small cell lung cancer (NSCLC) patients: chemotherapy and epidermal growth factor receptor (EGFR) inhibitor therapy. VeriStrat, a serum proteomic test, can be used to guide treatment decisions for NSCLC patients. The test classifies patients as likely to benefit from either of these two treatment options. The objective of this research was to model the anticipated survival and cost-effectiveness of four different treatment strategies: chemotherapy for all patients (C-all), EGFR inhibitor for all (E-all), a performance status guided selection strategy (PS-guided), and a strategy guided by VeriStrat test results (V-guided). We developed a Markov model with the perspective of the U.S. health care system. Model inputs were taken from published literature for the base-case analysis. One-way and probabilistic sensitivity analyses were performed. The C-all treatment strategy showed the best overall survival outcome (10.1 months), followed by V-guided (9.6 months), PS-guided (9.2 months), and E-all (8.2 months) strategies. The incremental cost-effectiveness ratio (ICER) of a V-guided treatment strategy was $91,111 (vs. E-all) and $8462 (vs. PS-guided) per quality-adjusted life year (QALY). The ICER for C-all compared to V-guided was $105,616. This cost-utility analysis indicates that a treatment strategy guided by the VeriStrat test in patients receiving second-line therapy for NSCLC may experience an overall survival benefit at an incremental cost-effectiveness ratio that is reasonable when compared with other practices, including cancer treatments, generally covered in the U.S. health care system. However, treating all patients with chemotherapy yielded the greatest expected survival. Copyright © 2013. Published by Elsevier Ireland Ltd.

  12. Axial and Centrifugal Compressor Mean Line Flow Analysis Method

    NASA Technical Reports Server (NTRS)

    Veres, Joseph P.

    2009-01-01

    This paper describes a method to estimate key aerodynamic parameters of single and multistage axial and centrifugal compressors. This mean-line compressor code COMDES provides the capability of sizing single and multistage compressors quickly during the conceptual design process. Based on the compressible fluid flow equations and the Euler equation, the code can estimate rotor inlet and exit blade angles when run in the design mode. The design point rotor efficiency and stator losses are inputs to the code, and are modeled at off design. When run in the off-design analysis mode, it can be used to generate performance maps based on simple models for losses due to rotor incidence and inlet guide vane reset angle. The code can provide an improved understanding of basic aerodynamic parameters such as diffusion factor, loading levels and incidence, when matching multistage compressor blade rows at design and at part-speed operation. Rotor loading levels and relative velocity ratio are correlated to the onset of compressor surge. NASA Stage 37 and the three-stage NASA 74-A axial compressors were analyzed and the results compared to test data. The code has been used to generate the performance map for the NASA 76-B three-stage axial compressor featuring variable geometry. The compressor stages were aerodynamically matched at off-design speeds by adjusting the variable inlet guide vane and variable stator geometry angles to control the rotor diffusion factor and incidence angles.

  13. Clinical, information and business process modeling to promote development of safe and flexible software.

    PubMed

    Liaw, Siaw-Teng; Deveny, Elizabeth; Morrison, Iain; Lewis, Bryn

    2006-09-01

    Using a factorial vignette survey and modeling methodology, we developed clinical and information models - incorporating evidence base, key concepts, relevant terms, decision-making and workflow needed to practice safely and effectively - to guide the development of an integrated rule-based knowledge module to support prescribing decisions in asthma. We identified workflows, decision-making factors, factor use, and clinician information requirements. The Unified Modeling Language (UML) and public domain software and knowledge engineering tools (e.g. Protégé) were used, with the Australian GP Data Model as the starting point for expressing information needs. A Web Services service-oriented architecture approach was adopted within which to express functional needs, and clinical processes and workflows were expressed in the Business Process Execution Language (BPEL). This formal analysis and modeling methodology to define and capture the process and logic of prescribing best practice in a reference implementation is fundamental to tackling deficiencies in prescribing decision support software.

  14. Development of conceptual ecological models linking management of the Missouri River to pallid sturgeon population dynamics

    USGS Publications Warehouse

    Jacobson, Robert B.; Parsley, Michael J.; Annis, Mandy L.; Colvin, Michael E.; Welker, Timothy L.; James, Daniel A.

    2015-01-01

    This report documents the process of developing and refining conceptual ecological models (CEMs) for linking river management to pallid sturgeon (Scaphirhynchus albus) population dynamics in the Missouri River. The refined CEMs are being used in the Missouri River Pallid Sturgeon Effects Analysis to organize, document, and formalize an understanding of pallid sturgeon population responses to past and future management alternatives. The general form of the CEMs, represented by a population-level model and component life-stage models, was determined in workshops held in the summer of 2013. Subsequently, the Missouri River Pallid Sturgeon Effects Analysis team designed a general hierarchical structure for the component models, refined the graphical structure, and reconciled variation among the components and between models developed for the upper river (Upper Missouri & Yellowstone Rivers) and the lower river (Missouri River downstream from Gavins Point Dam). Importance scores attributed to the relations between primary biotic characteristics and survival were used to define a candidate set of working dominant hypotheses about pallid sturgeon population dynamics. These CEMs are intended to guide research and adaptive-management actions to benefit pallid sturgeon populations in the Missouri River.

  15. Discrete Choice Experiments: A Guide to Model Specification, Estimation and Software.

    PubMed

    Lancsar, Emily; Fiebig, Denzil G; Hole, Arne Risa

    2017-07-01

    We provide a user guide on the analysis of data (including best-worst and best-best data) generated from discrete-choice experiments (DCEs), comprising a theoretical review of the main choice models followed by practical advice on estimation and post-estimation. We also provide a review of standard software. In providing this guide, we endeavour to not only provide guidance on choice modelling but to do so in a way that provides a 'way in' for researchers to the practicalities of data analysis. We argue that choice of modelling approach depends on the research questions, study design and constraints in terms of quality/quantity of data and that decisions made in relation to analysis of choice data are often interdependent rather than sequential. Given the core theory and estimation of choice models is common across settings, we expect the theoretical and practical content of this paper to be useful to researchers not only within but also beyond health economics.

  16. Consistency analysis on laser signal in laser guided weapon simulation

    NASA Astrophysics Data System (ADS)

    Yin, Ruiguang; Zhang, Wenpan; Guo, Hao; Gan, Lin

    2015-10-01

    The hardware-in-the-loop simulation is widely used in laser semi-active guidance weapon experiments, the authenticity of the laser guidance signal is the key problem of reliability. In order to evaluate the consistency of the laser guidance signal, this paper analyzes the angle of sight, laser energy density, laser spot size, atmospheric back scattering, sun radiation and SNR by comparing the different working state between actual condition and hardware-in-the-loop simulation. Based on measured data, mathematical simulation and optical simulation result, laser guidance signal effects on laser seeker are determined. By using Monte Carlo method, the laser guided weapon trajectory and impact point distribution are obtained, the influence of the systematic error are analyzed. In conclusion it is pointed out that the difference between simulation system and actual system has little influence in normal guidance, has great effect on laser jamming. The research is helpful to design and evaluation of laser guided weapon simulation.

  17. Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prakash, P.; Zbijewski, W.; Gang, G. J.

    2011-10-15

    Purpose: This work applies a cascaded systems model for cone-beam CT imaging performance to the design and optimization of a system for musculoskeletal extremity imaging. The model provides a quantitative guide to the selection of system geometry, source and detector components, acquisition techniques, and reconstruction parameters. Methods: The model is based on cascaded systems analysis of the 3D noise-power spectrum (NPS) and noise-equivalent quanta (NEQ) combined with factors of system geometry (magnification, focal spot size, and scatter-to-primary ratio) and anatomical background clutter. The model was extended to task-based analysis of detectability index (d') for tasks ranging in contrast and frequencymore » content, and d' was computed as a function of system magnification, detector pixel size, focal spot size, kVp, dose, electronic noise, voxel size, and reconstruction filter to examine trade-offs and optima among such factors in multivariate analysis. The model was tested quantitatively versus the measured NPS and qualitatively in cadaver images as a function of kVp, dose, pixel size, and reconstruction filter under conditions corresponding to the proposed scanner. Results: The analysis quantified trade-offs among factors of spatial resolution, noise, and dose. System magnification (M) was a critical design parameter with strong effect on spatial resolution, dose, and x-ray scatter, and a fairly robust optimum was identified at M {approx} 1.3 for the imaging tasks considered. The results suggested kVp selection in the range of {approx}65-90 kVp, the lower end (65 kVp) maximizing subject contrast and the upper end maximizing NEQ (90 kVp). The analysis quantified fairly intuitive results--e.g., {approx}0.1-0.2 mm pixel size (and a sharp reconstruction filter) optimal for high-frequency tasks (bone detail) compared to {approx}0.4 mm pixel size (and a smooth reconstruction filter) for low-frequency (soft-tissue) tasks. This result suggests a specific protocol for 1 x 1 (full-resolution) projection data acquisition followed by full-resolution reconstruction with a sharp filter for high-frequency tasks along with 2 x 2 binning reconstruction with a smooth filter for low-frequency tasks. The analysis guided selection of specific source and detector components implemented on the proposed scanner. The analysis also quantified the potential benefits and points of diminishing return in focal spot size, reduced electronic noise, finer detector pixels, and low-dose limits of detectability. Theoretical results agreed quantitatively with the measured NPS and qualitatively with evaluation of cadaver images by a musculoskeletal radiologist. Conclusions: A fairly comprehensive model for 3D imaging performance in cone-beam CT combines factors of quantum noise, system geometry, anatomical background, and imaging task. The analysis provided a valuable, quantitative guide to design, optimization, and technique selection for a musculoskeletal extremities imaging system under development.« less

  18. Waveform analysis-guided treatment versus a standard shock-first protocol for the treatment of out-of-hospital cardiac arrest presenting in ventricular fibrillation: results of an international randomized, controlled trial.

    PubMed

    Freese, John P; Jorgenson, Dawn B; Liu, Ping-Yu; Innes, Jennifer; Matallana, Luis; Nammi, Krishnakant; Donohoe, Rachael T; Whitbread, Mark; Silverman, Robert A; Prezant, David J

    2013-08-27

    Ventricular fibrillation (VF) waveform properties have been shown to predict defibrillation success and outcomes among patients treated with immediate defibrillation. We postulated that a waveform analysis algorithm could be used to identify VF unlikely to respond to immediate defibrillation, allowing selective initial treatment with cardiopulmonary resuscitation in an effort to improve overall survival. In a multicenter, double-blind, randomized study, out-of-hospital cardiac arrest patients in 2 urban emergency medical services systems were treated with automated external defibrillators using either a VF waveform analysis algorithm or the standard shock-first protocol. The VF waveform analysis used a predefined threshold value below which return of spontaneous circulation (ROSC) was unlikely with immediate defibrillation, allowing selective treatment with a 2-minute interval of cardiopulmonary resuscitation before initial defibrillation. The primary end point was survival to hospital discharge. Secondary end points included ROSC, sustained ROSC, and survival to hospital admission. Of 6738 patients enrolled, 987 patients with VF of primary cardiac origin were included in the primary analysis. No immediate or long-term survival benefit was noted for either treatment algorithm (ROSC, 42.5% versus 41.2%, P=0.70; sustained ROSC, 32.4% versus 33.4%, P=0.79; survival to admission, 34.1% versus 36.4%, P=0.46; survival to hospital discharge, 15.6% versus 17.2%, P=0.55, respectively). Use of a waveform analysis algorithm to guide the initial treatment of out-of-hospital cardiac arrest patients presenting in VF did not improve overall survival compared with a standard shock-first protocol. Further study is recommended to examine the role of waveform analysis for the guided management of VF.

  19. Toward standardized reporting for a cohort study on functioning: The Swiss Spinal Cord Injury Cohort Study.

    PubMed

    Prodinger, Birgit; Ballert, Carolina S; Brach, Mirjam; Brinkhof, Martin W G; Cieza, Alarcos; Hug, Kerstin; Jordan, Xavier; Post, Marcel W M; Scheel-Sailer, Anke; Schubert, Martin; Tennant, Alan; Stucki, Gerold

    2016-02-01

    Functioning is an important outcome to measure in cohort studies. Clear and operational outcomes are needed to judge the quality of a cohort study. This paper outlines guiding principles for reporting functioning in cohort studies and addresses some outstanding issues. Principles of how to standardize reporting of data from a cohort study on functioning, by deriving scores that are most useful for further statistical analysis and reporting, are outlined. The Swiss Spinal Cord Injury Cohort Study Community Survey serves as a case in point to provide a practical application of these principles. Development of reporting scores must be conceptually coherent and metrically sound. The International Classification of Functioning, Disability and Health (ICF) can serve as the frame of reference for this, with its categories serving as reference units for reporting. To derive a score for further statistical analysis and reporting, items measuring a single latent trait must be invariant across groups. The Rasch measurement model is well suited to test these assumptions. Our approach is a valuable guide for researchers and clinicians, as it fosters comparability of data, strengthens the comprehensiveness of scope, and provides invariant, interval-scaled data for further statistical analyses of functioning.

  20. Surveillance-guided selective digestive decontamination of carbapenem-resistant Enterobacteriaceae in the intensive care unit: A cost-effectiveness analysis.

    PubMed

    You, Joyce H S; Li, Hong-Kiu; Ip, Margaret

    2018-03-01

    Clinical findings have shown effectiveness and safety of selective digestive decontamination (SDD) for eradication of carbapenem-resistant Enterobacteriaceae (CRE) in high-risk carriers. We aimed to evaluate the cost-effectiveness of SDD guided by CRE surveillance in the intensive care unit (ICU). Outcomes of surveillance-guided SDD (test-guided SDD) and no screening (control) in the ICU were compared by Markov model simulations. Model outcomes were CRE infection and mortality rates, direct costs, and quality-adjusted life year (QALY) loss. Model inputs were estimated from clinical literature. Sensitivity analyses were conducted to examine the robustness of base case results. Test-guided SDD reduced infection (4.8% vs 5.0%) and mortality (1.8% vs 2.1%) rates at a higher cost ($1,102 vs $1,074) than the control group in base case analysis, respectively. Incremental cost per QALY saved (incremental cost-effectiveness ratio [ICER]) by the test-guided SDD group was $557 per QALY. Probabilistic sensitivity analysis showed that test-guided SDD was effective in saving QALYs in 100% of 10,000 Monte Carlo simulations, and cost-saving 59.1% of time. The remaining 40.9% of simulations found SDD to be effective at an additional cost, with ICERs accepted as cost-effective per the willingness-to-pay threshold. Surveillance-guided SDD appears to be cost-effective in reducing CRE infection and mortality with QALYs saved. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  1. Can we use mice to study schizophrenia?

    PubMed

    Canetta, Sarah; Kellendonk, Christoph

    2018-03-19

    The validity of rodent models for the study of psychiatric disorders is controversial. Despite great efforts from academic institutions and pharmaceutical companies, as of today, no major therapeutic intervention has been developed for the treatment of psychiatric disorders based on mechanistic insights from rodent models. Here, we argue that despite these historical shortcomings, rodent studies are nevertheless instrumental for identifying neuronal circuit mechanisms underlying behaviours that are affected in psychiatric disorders. Focusing on schizophrenia, we will give four examples of rodent models that were generated based on genetic and environmental risk factors or pathophysiological evidence as entry points. We will then discuss how circuit analysis in these specific examples can be used for testing hypotheses about neuronal mechanisms underlying symptoms of schizophrenia, which will then guide the development of new therapies.This article is part of a discussion meeting issue 'Of mice and mental health: facilitating dialogue between basic and clinical neuroscientists'. © 2018 The Author(s).

  2. Simulation of the Francis-99 Hydro Turbine During Steady and Transient Operation

    NASA Astrophysics Data System (ADS)

    Dewan, Yuvraj; Custer, Chad; Ivashchenko, Artem

    2017-01-01

    Numerical simulation of the Francis-99 hydroturbine with correlation to experimental measurements are presented. Steady operation of the hydroturbine is analyzed at three operating conditions: the best efficiency point (BEP), high load (HL), and part load (PL). It is shown that global quantities such as net head, discharge and efficiency are well predicted. Additionally, time-averaged velocity predictions compare well with PIV measurements obtained in the draft tube immediately downstream of the runner. Differences in vortex rope structure between operating points are discussed. Unsteady operation of the hydroturbine from BEP to HL and from BEP to PL are modeled. It is shown that simulation methods used to model the steady operation produce predictions that correlate well with experiment for transient operation. Time-domain unsteady simulation is used for both steady and unsteady operation. The full-fidelity geometry including all components is meshed using an unstructured polyhedral mesh with body-fitted prism layers. Guide vane rotation for transient operation is imposed using fully-conservative, computationally efficient mesh morphing. The commercial solver STAR-CCM+ is used for all portions of the analysis including meshing, solving and post-processing.

  3. In the Opponent's Shoes: Increasing the Behavioral Validity of Attackers' Judgments in Counterterrorism Models.

    PubMed

    Sri Bhashyam, Sumitra; Montibeller, Gilberto

    2016-04-01

    A key objective for policymakers and analysts dealing with terrorist threats is trying to predict the actions that malicious agents may take. A recent trend in counterterrorism risk analysis is to model the terrorists' judgments, as these will guide their choices of such actions. The standard assumptions in most of these models are that terrorists are fully rational, following all the normative desiderata required for rational choices, such as having a set of constant and ordered preferences, being able to perform a cost-benefit analysis of their alternatives, among many others. However, are such assumptions reasonable from a behavioral perspective? In this article, we analyze the types of assumptions made across various counterterrorism analytical models that represent malicious agents' judgments and discuss their suitability from a descriptive point of view. We then suggest how some of these assumptions could be modified to describe terrorists' preferences more accurately, by drawing knowledge from the fields of behavioral decision research, politics, philosophy of choice, public choice, and conflict management in terrorism. Such insight, we hope, might help make the assumptions of these models more behaviorally valid for counterterrorism risk analysis. © 2016 The Authors Wound Repair and Regeneration published by Wiley Periodicals, Inc. on behalf of The Wound Healing Society.

  4. Development of the promoting teacher attribution model for promoting science teachers' moral and ethical characteristics

    NASA Astrophysics Data System (ADS)

    Chanprathak, Anusorn; Worakham, Paisan; Suikraduang, Arun

    2018-01-01

    The promotion science teacher attribution model to develop the moral and ethical characteristics was to analyze, synthesis, and develop the guidelines of the scoping study into concepts, theories and research related about the moral and ethics of characteristically teachers from the resources, including research papers, research articles related research, and interviews with luminaries of 9 members. Using interviews and document analysis, data analysis, content analysis, and present an essay was built. The promoting attributes a teacher, moral principles, concepts and theories involved and guidance of a qualified were developed. The Multiple-Attribute Consensus Reaching (MACR) from 12 educational experts were checked the suitability and feasibility of the model, the possibility of the manual with the research instruments consisted of the promotion model attributes the moral and ethics teacher's characteristics were evaluated, to guide the promotion attributes' model forms were assessed, the first edition of the manual data analysis, information obtained from the evaluation of the suitability and feasibility analysis model and guide for the average were administered. The results have found that; the promoting moral teacher attribute data to their moral and ethical characteristics was divided into two groups, priests and scholars. In both groups, the promotion attributes, focusing on teacher's groups is moral in nature to modify the idea to a change of attitude within the organism. Students got down to real experience; an analysis and synthesis face learning environments that cause cognitive skills to act as a self-realization possibly. The promotion model, moral principles, including the importance of the activities, objectives and evaluation methods were attributed. These core concepts learning theory and social cognitive theory, and integrated learning experience were comprised in five stages and four processes, namely; the intended, memory storage process, the actions, and the incentives of the motivation processes. The appropriateness and feasibility of the model and the appropriateness of the form scales evidence of a high level. The assessing guide on the appropriateness of the guide scale and the possibility of the manual guide responded of at a high level, similarly.

  5. Development of Animal Physiology Practical Guidance Oriented Guided Inquiry for Student of Biology Department

    NASA Astrophysics Data System (ADS)

    Putra, Z. A. Z.; Sumarmin, R.; Violita, V.

    2018-04-01

    The guides used for practicing animal physiology need to be revised and adapted to the lecture material. This is because in the subject of Animal Physiology. The guidance of animal physiology practitioners is still conventional with prescription model instructions and is so simple that it is necessary to develop a practical guide that can lead to the development of scientific work. One of which is through practice guided inquiry guided practicum guide. This study aims to describe the process development of the practical guidance and reveal the validity, practicality, and effectiveness Guidance Physiology Animals guided inquiry inferior to the subject of Animal Physiology for students Biology Department State University of Padang. This type of research is development research. This development research uses the Plomp model. Stages performed are problem identification and analysis stage, prototype development and prototyping stage, and assessment phase. Data analysis using descriptive analysis. The instrument of data collection using validation and practical questionnaires, competence and affective field of competence observation and psychomotor and cognitive domain competence test. The result of this research shows that guidance of Inquiry Guided Initiative Guided Physiology with 3.23 valid category, practicality by lecturer with value 3.30 practical category, student with value 3.37 practical criterion. Affective effectiveness test with 93,00% criterion is very effective, psychomotor aspect 89,50% with very effective criteria and cognitive domain with value of 67, pass criterion. The conclusion of this research is Guided Inquiry Student Guided Protoxial Guidance For Students stated valid, practical and effective.

  6. Users Guide for Fire Image Analysis System - Version 5.0: A Tool for Measuring Fire Behavior Characteristics

    Treesearch

    Carl W. Adkins

    1995-01-01

    The Fire Image Analysis System is a tool for quantifying flame geometry and relative position at selected points along a spreading line fire. At present, the system requires uniform terrain (constant slope). The system has been used in field and laboratory studies for determining flame length, depth, cross sectional area, and rate of spread.

  7. A Comprehensive Analysis of the Quality of Online Health-Related Information regarding Schizophrenia

    ERIC Educational Resources Information Center

    Guada, Joseph; Venable, Victoria

    2011-01-01

    Social workers are major mental health providers and, thus, can be key players in guiding consumers and their families to accurate information regarding schizophrenia. The present study, using the WebMedQual scale, is a comprehensive analysis across a one-year period at two different time points of the top for-profit and nonprofit sites that…

  8. Genetic Algorithm-Guided, Adaptive Model Order Reduction of Flexible Aircrafts

    NASA Technical Reports Server (NTRS)

    Zhu, Jin; Wang, Yi; Pant, Kapil; Suh, Peter; Brenner, Martin J.

    2017-01-01

    This paper presents a methodology for automated model order reduction (MOR) of flexible aircrafts to construct linear parameter-varying (LPV) reduced order models (ROM) for aeroservoelasticity (ASE) analysis and control synthesis in broad flight parameter space. The novelty includes utilization of genetic algorithms (GAs) to automatically determine the states for reduction while minimizing the trial-and-error process and heuristics requirement to perform MOR; balanced truncation for unstable systems to achieve locally optimal realization of the full model; congruence transformation for "weak" fulfillment of state consistency across the entire flight parameter space; and ROM interpolation based on adaptive grid refinement to generate a globally functional LPV ASE ROM. The methodology is applied to the X-56A MUTT model currently being tested at NASA/AFRC for flutter suppression and gust load alleviation. Our studies indicate that X-56A ROM with less than one-seventh the number of states relative to the original model is able to accurately predict system response among all input-output channels for pitch, roll, and ASE control at various flight conditions. The GA-guided approach exceeds manual and empirical state selection in terms of efficiency and accuracy. The adaptive refinement allows selective addition of the grid points in the parameter space where flight dynamics varies dramatically to enhance interpolation accuracy without over-burdening controller synthesis and onboard memory efforts downstream. The present MOR framework can be used by control engineers for robust ASE controller synthesis and novel vehicle design.

  9. Preparation of the implementation plan of AASHTO Mechanistic-Empirical Pavement Design Guide (M-EPDG) in Connecticut : Phase II : expanded sensitivity analysis and validation with pavement management data.

    DOT National Transportation Integrated Search

    2017-02-08

    The study re-evaluates distress prediction models using the Mechanistic-Empirical Pavement Design Guide (MEPDG) and expands the sensitivity analysis to a wide range of pavement structures and soils. In addition, an extensive validation analysis of th...

  10. Creating a mobile subject guide to improve access to point-of-care resources for medical students: a case study

    PubMed Central

    Boruff, Jill T; Bilodeau, Edward

    2012-01-01

    Question: Can a mobile optimized subject guide facilitate medical student access to mobile point-of-care tools? Setting: The guide was created at a library at a research-intensive university with six teaching hospital sites. Objectives: The team created a guide facilitating medical student access to point-of-care tools directly on mobile devices to provide information allowing them to access and set up resources with little assistance. Methods: Two librarians designed a mobile optimized subject guide for medicine and conducted a survey to test its usefulness. Results: Web analytics and survey results demonstrate that the guide is used and the students are satisfied. Conclusion: The library will continue to use the subject guide as its primary means of supporting mobile devices. It remains to be seen if the mobile guide facilitates access for those who do not need assistance and want direct access to the resources. Internet access in the hospitals remains an issue. PMID:22272160

  11. Creating a mobile subject guide to improve access to point-of-care resources for medical students: a case study.

    PubMed

    Boruff, Jill T; Bilodeau, Edward

    2012-01-01

    Can a mobile optimized subject guide facilitate medical student access to mobile point-of-care tools? The guide was created at a library at a research-intensive university with six teaching hospital sites. The team created a guide facilitating medical student access to point-of-care tools directly on mobile devices to provide information allowing them to access and set up resources with little assistance. Two librarians designed a mobile optimized subject guide for medicine and conducted a survey to test its usefulness. Web analytics and survey results demonstrate that the guide is used and the students are satisfied. The library will continue to use the subject guide as its primary means of supporting mobile devices. It remains to be seen if the mobile guide facilitates access for those who do not need assistance and want direct access to the resources. Internet access in the hospitals remains an issue.

  12. Theoretical, Experimental, and Computational Evaluation of Disk-Loaded Circular Wave Guides

    NASA Technical Reports Server (NTRS)

    Wallett, Thomas M.; Qureshi, A. Haq

    1994-01-01

    A disk-loaded circular wave guide structure and test fixture were fabricated. The dispersion characteristics were found by theoretical analysis, experimental testing, and computer simulation using the codes ARGUS and SOS. Interaction impedances were computed based on the corresponding dispersion characteristics. Finally, an equivalent circuit model for one period of the structure was chosen using equivalent circuit models for cylindrical wave guides of different radii. Optimum values for the discrete capacitors and inductors describing discontinuities between cylindrical wave guides were found using the computer code TOUCHSTONE.

  13. Visualizing nD Point Clouds as Topological Landscape Profiles to Guide Local Data Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oesterling, Patrick; Heine, Christian; Weber, Gunther H.

    2012-05-04

    Analyzing high-dimensional point clouds is a classical challenge in visual analytics. Traditional techniques, such as projections or axis-based techniques, suffer from projection artifacts, occlusion, and visual complexity.We propose to split data analysis into two parts to address these shortcomings. First, a structural overview phase abstracts data by its density distribution. This phase performs topological analysis to support accurate and non-overlapping presentation of the high-dimensional cluster structure as a topological landscape profile. Utilizing a landscape metaphor, it presents clusters and their nesting as hills whose height, width, and shape reflect cluster coherence, size, and stability, respectively. A second local analysis phasemore » utilizes this global structural knowledge to select individual clusters or point sets for further, localized data analysis. Focusing on structural entities significantly reduces visual clutter in established geometric visualizations and permits a clearer, more thorough data analysis. In conclusion, this analysis complements the global topological perspective and enables the user to study subspaces or geometric properties, such as shape.« less

  14. Single-Molecule Counting of Point Mutations by Transient DNA Binding

    NASA Astrophysics Data System (ADS)

    Su, Xin; Li, Lidan; Wang, Shanshan; Hao, Dandan; Wang, Lei; Yu, Changyuan

    2017-03-01

    High-confidence detection of point mutations is important for disease diagnosis and clinical practice. Hybridization probes are extensively used, but are hindered by their poor single-nucleotide selectivity. Shortening the length of DNA hybridization probes weakens the stability of the probe-target duplex, leading to transient binding between complementary sequences. The kinetics of probe-target binding events are highly dependent on the number of complementary base pairs. Here, we present a single-molecule assay for point mutation detection based on transient DNA binding and use of total internal reflection fluorescence microscopy. Statistical analysis of single-molecule kinetics enabled us to effectively discriminate between wild type DNA sequences and single-nucleotide variants at the single-molecule level. A higher single-nucleotide discrimination is achieved than in our previous work by optimizing the assay conditions, which is guided by statistical modeling of kinetics with a gamma distribution. The KRAS c.34 A mutation can be clearly differentiated from the wild type sequence (KRAS c.34 G) at a relative abundance as low as 0.01% mutant to WT. To demonstrate the feasibility of this method for analysis of clinically relevant biological samples, we used this technology to detect mutations in single-stranded DNA generated from asymmetric RT-PCR of mRNA from two cancer cell lines.

  15. Treating the Tough Adolescent: A Family-Based, Step-by-Step Guide. The Guilford Family Therapy Series.

    ERIC Educational Resources Information Center

    Sells, Scott P.

    A model for treating difficult adolescents and their families is presented. Part 1 offers six basic assumptions about the causes of severe behavioral problems and presents the treatment model with guidelines necessary to address each of these six causes. Case examples highlight and clarify major points within each of the 15 procedural steps of the…

  16. Kinematic analysis and simulation of a substation inspection robot guided by magnetic sensor

    NASA Astrophysics Data System (ADS)

    Xiao, Peng; Luan, Yiqing; Wang, Haipeng; Li, Li; Li, Jianxiang

    2017-01-01

    In order to improve the performance of the magnetic navigation system used by substation inspection robot, the kinematic characteristics is analyzed based on a simplified magnetic guiding system model, and then the simulation process is executed to verify the reasonability of the whole analysis procedure. Finally, some suggestions are extracted out, which will be helpful to guide the design of the inspection robot system in the future.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cornwell, Paris A; Bunn, Jeffrey R; Schmidlin, Joshua E

    The December 2010 version of the guide, ORNL/TM-2008/159, by Jeff Bunn, Josh Schmidlin, Camden Hubbard, and Paris Cornwell, has been further revised due to a major change in the GeoMagic Studio software for constructing a surface model. The Studio software update also includes a plug-in module to operate the FARO Scan Arm. Other revisions for clarity were also made. The purpose of this revision document is to guide the reader through the process of laser alignment used by NRSF2 at HFIR and VULCAN at SNS. This system was created to increase the spatial accuracy of the measurement points in amore » sample, reduce the use of neutron time used for alignment, improve experiment planning, and reduce operator error. The need for spatial resolution has been driven by the reduction in gauge volumes to the sub-millimeter level, steep strain gradients in some samples, and requests to mount multiple samples within a few days for relating data from each sample to a common sample coordinate system. The first step in this process involves mounting the sample on an indexer table in a laboratory set up for offline sample mounting and alignment in the same manner it would be mounted at either instrument. In the shared laboratory, a FARO ScanArm is used to measure the coordinates of points on the sample surface ('point cloud'), specific features and fiducial points. A Sample Coordinate System (SCS) needs to be established first. This is an advantage of the technique because the SCS can be defined in such a way to facilitate simple definition of measurement points within the sample. Next, samples are typically mounted to a frame of 80/20 and fiducial points are attached to the sample or frame then measured in the established sample coordinate system. The laser scan probe on the ScanArm can then be used to scan in an 'as-is' model of the sample as well as mounting hardware. GeoMagic Studio 12 is the software package used to construct the model from the point cloud the scan arm creates. Once a model, fiducial, and measurement files are created, a special program, called SScanSS combines the information and by simulation of the sample on the diffractometer can help plan the experiment before using neutron time. Finally, the sample is mounted on the relevant stress measurement instrument and the fiducial points are measured again. In the HFIR beam room, a laser tracker is used in conjunction with a program called CAM2 to measure the fiducial points in the NRSF2 instrument's sample positioner coordinate system. SScanSS is then used again to perform a coordinate system transformation of the measurement file locations to the sample positioner coordinate system. A procedure file is then written with the coordinates in the sample positioner coordinate system for the desired measurement locations. This file is often called a script or command file and can be further modified using excel. It is very important to note that this process is not a linear one, but rather, it often is iterative. Many of the steps in this guide are interdependent on one another. It is very important to discuss the process as it pertains to the specific sample being measured. What works with one sample may not necessarily work for another. This guide attempts to provide a typical work flow that has been successful in most cases.« less

  18. Cost-effectiveness analysis of personalized antiplatelet therapy in patients with acute coronary syndrome.

    PubMed

    Jiang, Minghuan; You, Joyce Hs

    2016-05-01

    This study aimed to compare the clinical and economic outcomes of pharmacogenetic-guided (PG-guided) and platelet reactivity testing-guided antiplatelet therapy for patients with acute coronary syndrome undergoing percutaneous coronary intervention. A decision-analytic model was simulated including four antiplatelet strategies: universal clopidogrel 75 mg daily, universal alternative P2Y12 inhibitor (prasugrel or ticagrelor), PG-guided therapy, and platelet reactivity testing-guided therapy. PG-guided therapy was the preferred option with lowest cost (US$75,208) and highest quality-adjusted life years gained (7.6249 quality-adjusted life years). The base-case results were robust in sensitivity analysis. PG-guided antiplatelet therapy showed the highest probability to be preferred antiplatelet strategy for acute coronary syndrome patients with percutaneous coronary intervention.

  19. Traffic analysis toolbox volume XI : weather and traffic analysis, modeling and simulation.

    DOT National Transportation Integrated Search

    2010-12-01

    This document presents a weather module for the traffic analysis tools program. It provides traffic engineers, transportation modelers and decisions makers with a guide that can incorporate weather impacts into transportation system analysis and mode...

  20. Simulation and analysis of the effect of ungrounded rectangular loop distributed parameters on TEM response

    NASA Astrophysics Data System (ADS)

    Shi, Zongyang; Liu, Lihua; Xiao, Pan; Geng, Zhi; Liu, Fubo; Fang, Guangyou

    2018-02-01

    An ungrounded loop in the shallow subsurface transient electromagnetic surveys has been studied as the transmission line model for early turn-off stage, which can accurately explicate the early turn-off current waveform inconsistency along the loop. In this paper, the Gauss-Legendre numerical integration method is proposed for the first time to simulate and analyze the transient electromagnetic (TEM) response considering the different early turn-off current waveforms along the loop. During the simulation, these integral node positions along the loop are firstly determined by solving these zero points of Legendre polynomial, then the turn-off current of each node position is simulated by using the transfer function of the transmission line. Finally, the total TEM response is calculated by using the Gauss-Legendre integral formula. In addition, the comparison and analysis between the results affected by the distributed parameters and that generated by lumped parameters are presented. It is found that the TEM responses agree well with each other after current is thoroughly switched off, while the transient responses in turn-off stage are completely different. It means that the position dependence of the early turn-off current should be introduced into the forward model during the early response data interpretation of the shallow TEM detection of the ungrounded loop. Furthermore, the TEM response simulations at four geometric symmetry points are made. It shows that early responses of different geometric symmetry points are also inconsistent. The research on the influence of turn-off current position dependence on the early response of geometric symmetry point is of great significance to guide the layout of the survey lines and the transmitter location.

  1. Sensor-Based Electromagnetic Navigation (Mediguide®): How Accurate Is It? A Phantom Model Study.

    PubMed

    Bourier, Felix; Reents, Tilko; Ammar-Busch, Sonia; Buiatti, Alessandra; Grebmer, Christian; Telishevska, Marta; Brkic, Amir; Semmler, Verena; Lennerz, Carsten; Kaess, Bernhard; Kottmaier, Marc; Kolb, Christof; Deisenhofer, Isabel; Hessling, Gabriele

    2015-10-01

    Data about localization reproducibility as well as spatial and visual accuracy of the new MediGuide® sensor-based electroanatomic navigation technology are scarce. We therefore sought to quantify these parameters based on phantom experiments. A realistic heart phantom was generated in a 3D-Printer. A CT scan was performed on the phantom. The phantom itself served as ground-truth reference to ensure exact and reproducible catheter placement. A MediGuide® catheter was repeatedly tagged at selected positions to assess accuracy of point localization. The catheter was also used to acquire a MediGuide®-scaled geometry in the EnSite Velocity® electroanatomic mapping system. The acquired geometries (MediGuide®-scaled and EnSite Velocity®-scaled) were compared to a CT segmentation of the phantom to quantify concordance. Distances between landmarks were measured in the EnSite Velocity®- and MediGuide®-scaled geometry and the CT dataset for Bland-Altman comparison. The visualization of virtual MediGuide® catheter tips was compared to their corresponding representation on fluoroscopic cine-loops. Point localization accuracy was 0.5 ± 0.3 mm for MediGuide® and 1.4 ± 0.7 mm for EnSite Velocity®. The 3D accuracy of the geometries was 1.1 ± 1.4 mm (MediGuide®-scaled) and 3.2 ± 1.6 mm (not MediGuide®-scaled). The offset between virtual MediGuide® catheter visualization and catheter representation on corresponding fluoroscopic cine-loops was 0.4 ± 0.1 mm. The MediGuide® system shows a very high level of accuracy regarding localization reproducibility as well as spatial and visual accuracy, which can be ascribed to the magnetic field localization technology. The observed offsets between the geometry visualization and the real phantom are below a clinically relevant threshold. © 2015 Wiley Periodicals, Inc.

  2. 75 FR 16202 - Notice of Issuance of Regulatory Guide

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-31

    ..., Revision 2, ``An Acceptable Model and Related Statistical Methods for the Analysis of Fuel Densification.... Introduction The U.S. Nuclear Regulatory Commission (NRC) is issuing a revision to an existing guide in the... nuclear power reactors. To meet these objectives, the guide describes statistical methods related to...

  3. The response of guide dogs and pet dogs (Canis familiaris) to cues of human referential communication (pointing and gaze).

    PubMed

    Ittyerah, Miriam; Gaunet, Florence

    2009-03-01

    The study raises the question of whether guide dogs and pet dogs are expected to differ in response to cues of referential communication given by their owners; especially since guide dogs grow up among sighted humans, and while living with their blind owners, they still have interactions with several sighted people. Guide dogs and pet dogs were required to respond to point, point and gaze, gaze and control cues of referential communication given by their owners. Results indicate that the two groups of dogs do not differ from each other, revealing that the visual status of the owner is not a factor in the use of cues of referential communication. Both groups of dogs have higher frequencies of performance and faster latencies for the point and the point and gaze cues as compared to gaze cue only. However, responses to control cues are below chance performance for the guide dogs, whereas the pet dogs perform at chance. The below chance performance of the guide dogs may be explained by a tendency among them to go and stand by the owner. The study indicates that both groups of dogs respond similarly in normal daily dyadic interaction with their owners and the lower comprehension of the human gaze may be a less salient cue among dogs in comparison to the pointing gesture.

  4. Vibroacoustics of the piano soundboard: Reduced models, mobility synthesis, and acoustical radiation regime

    NASA Astrophysics Data System (ADS)

    Boutillon, Xavier; Ege, Kerem

    2013-09-01

    In string musical instruments, the sound is radiated by the soundboard, subject to the strings excitation. This vibration of this rather complex structure is described here with models which need only a small number of parameters. Predictions of the models are compared with the results of experiments that have been presented in Ege et al. [Vibroacoustics of the piano soundboard: (non)linearity and modal properties in the low- and mid-frequency ranges, Journal of Sound and Vibration 332 (5) (2013) 1288-1305]. The apparent modal density of the soundboard of an upright piano in playing condition, as seen from various points of the structure, exhibits two well-separated regimes, below and above a frequency flim that is determined by the wood characteristics and by the distance between ribs. Above flim, most modes appear to be localised, presumably due to the irregularity of the spacing and height of the ribs. The low-frequency regime is predicted by a model which consists of coupled sub-structures: the two ribbed areas split by the main bridge and, in most cases, one or two so-called cut-off corners. In order to assess the dynamical properties of each of the subplates (considered here as homogeneous plates), we propose a derivation of the (low-frequency) modal density of an orthotropic homogeneous plate which accounts for the boundary conditions on an arbitrary geometry. Above flim, the soundboard, as seen from a given excitation point, is modelled as a set of three structural wave-guides, namely the three inter-rib spacings surrounding the excitation point. Based on these low- and high-frequency models, computations of the point-mobility and of the apparent modal densities seen at several excitation points match published measurements. The dispersion curve of the wave-guide model displays an acoustical radiation scheme which differs significantly from that of a thin homogeneous plate. It appears that piano dimensioning is such that the subsonic regime of acoustical radiation extends over a much wider frequency range than it would be for a homogeneous plate with the same low-frequency vibration. One problem in piano manufacturing is examined in relationship with the possible radiation schemes induced by the models.

  5. Guiding brine shrimp through mazes by solving reaction diffusion equations

    NASA Astrophysics Data System (ADS)

    Singal, Krishma; Fenton, Flavio

    Excitable systems driven by reaction diffusion equations have been shown to not only find solutions to mazes but to also to find the shortest path between the beginning and the end of the maze. In this talk we describe how we can use the Fitzhugh-Nagumo model, a generic model for excitable media, to solve a maze by varying the basin of attraction of its two fixed points. We demonstrate how two dimensional mazes are solved numerically using a Java Applet and then accelerated to run in real time by using graphic processors (GPUs). An application of this work is shown by guiding phototactic brine shrimp through a maze solved by the algorithm. Once the path is obtained, an Arduino directs the shrimp through the maze using lights from LEDs placed at the floor of the Maze. This method running in real time could be eventually used for guiding robots and cars through traffic.

  6. Parental Acceptance-Rejection Theory and the Phylogenetic Model.

    ERIC Educational Resources Information Center

    Rohner, Ronald P.

    Guided by specific theoretical and methodological points of view--the phylogenetic perspective and the universalistic approach respectively--this paper reports on a worldwide study of the antecedents and effects of parental acceptance and rejection. Parental acceptance-rejection theory postulates that rejected children throughout our species share…

  7. Numerical studies of nonlinear ultrasonic guided waves in uniform waveguides with arbitrary cross sections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zuo, Peng; Fan, Zheng, E-mail: ZFAN@ntu.edu.sg; Zhou, Yu

    2016-07-15

    Nonlinear guided waves have been investigated widely in simple geometries, such as plates, pipe and shells, where analytical solutions have been developed. This paper extends the application of nonlinear guided waves to waveguides with arbitrary cross sections. The criteria for the existence of nonlinear guided waves were summarized based on the finite deformation theory and nonlinear material properties. Numerical models were developed for the analysis of nonlinear guided waves in complex geometries, including nonlinear Semi-Analytical Finite Element (SAFE) method to identify internal resonant modes in complex waveguides, and Finite Element (FE) models to simulate the nonlinear wave propagation at resonantmore » frequencies. Two examples, an aluminum plate and a steel rectangular bar, were studied using the proposed numerical model, demonstrating the existence of nonlinear guided waves in such structures and the energy transfer from primary to secondary modes.« less

  8. 2D Analytical Model for the Directivity Prediction of Ultrasonic Contact Type Transducers in the Generation of Guided Waves.

    PubMed

    Tiwari, Kumar Anubhav; Raisutis, Renaldas; Mazeika, Liudas; Samaitis, Vykintas

    2018-03-26

    In this paper, a novel 2D analytical model based on the Huygens's principle of wave propagation is proposed in order to predict the directivity patterns of contact type ultrasonic transducers in the generation of guided waves (GWs). The developed model is able to estimate the directivity patterns at any distance, at any excitation frequency and for any configuration and shape of the transducers with prior information of phase dispersive characteristics of the guided wave modes and the behavior of transducer. This, in turn, facilitates to choose the appropriate transducer or arrays of transducers, suitable guided wave modes and excitation frequency for the nondestructive testing (NDT) and structural health monitoring (SHM) applications. The model is demonstrated for P1-type macro-fiber composite (MFC) transducer glued on a 2 mm thick aluminum (Al) alloy plate. The directivity patterns of MFC transducer in the generation of fundamental guided Lamb modes (the S0 and A0) and shear horizontal mode (the SH0) are successfully obtained at 80 kHz, 5-period excitation signal. The results are verified using 3D finite element (FE) modelling and experimental investigation. The results obtained using the proposed model shows the good agreement with those obtained using numerical simulations and experimental analysis. The calculation time using the analytical model was significantly shorter as compared to the time spent in experimental analysis and FE numerical modelling.

  9. Laboratory Experiment of Magnetic Reconnection between Merging Flux Tubes with Strong Guide FIeld

    NASA Astrophysics Data System (ADS)

    Inomoto, M.; Kamio, S.; Kuwahata, A.; Ono, Y.

    2013-12-01

    Magnetic reconnection governs variety of energy release events in the universe, such as solar flares, geomagnetic substorms, and sawtooth crash in laboratory nuclear fusion experiments. Differently from the classical steady reconnection models, non-steady behavior of magnetic reconnection is often observed. In solar flares, intermittent enhancement of HXR emission is observed synchronously with multiple ejection of plammoids [1]. In laboratory reconnection experiments, the existence of the guide field, that is perpendicular to the reconnection field, makes significant changes on reconnection process. Generally the guide field will slow down the reconnection rate due to the increased magnetic pressure inside the current sheet. It also brings about asymmetric structure of the separatrices or effective particle acceleration in collisionless conditions. We have conducted laboratory experiments to study the behavior of the guide-field magnetic reconnection using plasma merging technique (push reconnection). Under substantial guide field even larger than the reconnection field, the reconnection generally exhibits non-steady feature which involves intermittent detachment of X-point and reconnection current center[2]. Transient enhancement of reconnection rate is observed simultaneously with the X-point motion[3]. We found two distinct phenomena associated with the guide-field non-steady reconnection. The one is the temporal and localized He II emission from X-point region, suggesting the production of energetic electrons which could excite the He ions in the vicinity of the X-point. The other is the excitation of large-amplitude electromagnetic waves which have similar properties with kinetic Alfven waves, whose amplitude show positive correlation with the enhancement of the reconnection electric field[4]. Electron beam instability caused by the energetic electrons accelerated to more than twice of the electron thermal velocity could be a potential driver of the monochromatic magnetic fluctuations. In conclusion, the laboratory guide field reconnection experiments showed some unique features such as ejection of current sheet, localized enhancement of emission, and excitation of low frequency waves, suggesting intermittent fast reconnection mechanism with significant electron acceleration. [1] N. Nishizuka et al., Astrophysical J. 711, 1062 (2010). [2] Y. Ono et al., Phys. Plasmas 18, 111213 (2011). [3] M. Inomoto et al., Plasma and Fusion Res. 8, 2401112 (2013). [4] M. Inomoto et al., Phys. Plasmas 20, 061209 (2013).

  10. A Practical Guide to Regression Discontinuity

    ERIC Educational Resources Information Center

    Jacob, Robin; Zhu, Pei; Somers, Marie-Andrée; Bloom, Howard

    2012-01-01

    Regression discontinuity (RD) analysis is a rigorous nonexperimental approach that can be used to estimate program impacts in situations in which candidates are selected for treatment based on whether their value for a numeric rating exceeds a designated threshold or cut-point. Over the last two decades, the regression discontinuity approach has…

  11. Performance Evaluation of the Gravity Probe B Design

    NASA Technical Reports Server (NTRS)

    Francis, Ronnie; Wells, Eugene M.

    1996-01-01

    This report documents the simulation of the Lockheed Martin designed Gravity Probe B (GPB) spacecraft developed tool by bd Systems Inc using the TREETOPS simulation. This study quantifies the effects of flexibility and liquid helium slosh on GPB spacecraft control performance. The TREETOPS simulation tool permits the simulation of flexible structures given that a flexible body model of the structure is available. For purposes of this study, a flexible model of the GPB spacecraft was obtained from Lockheed Martin. To model the liquid helium slosh effects, computational fluid dynamics (CFD) results' were obtained, and used to develop a dynamic model of the slosh effects. The flexible body and slosh effects were incorporated separately into the TREETOPS simulation, which places the vehicle in a 650 km circular polar orbit and subjects the spacecraft to realistic environmental disturbances and sensor error quantities. In all of the analysis conducted in this study the spacecraft is pointed at an inertially fixed guide star (GS) and is rotating at a constant rate about this line of sight.

  12. Predicting Condom Use Using the Information-Motivation-Behavioral Skills (IMB) Model: A Multivariate Latent Growth Curve Analysis

    PubMed Central

    Senn, Theresa E.; Scott-Sheldon, Lori A. J.; Vanable, Peter A.; Carey, Michael P.

    2011-01-01

    Background The Information-Motivation-Behavioral Skills (IMB) model often guides sexual risk reduction programs even though no studies have examined covariation in the theory’s constructs in a dynamic fashion with longitudinal data. Purpose Using new developments in latent growth modeling, we explore how changes in information, motivation, and behavioral skills over 9 months relate to changes in condom use among STD clinic patients. Methods Participants (N = 1281, 50% female, 66% African American) completed measures of IMB constructs at three time points. We used parallel process latent growth modeling to examine associations among intercepts and slopes of IMB constructs. Results Initial levels of motivation, behavioral skills, and condom use were all positively associated, with behavioral skills partially mediating associations between motivation and condom use. Changes over time in behavioral skills positively related to changes in condom use. Conclusions Results support the key role of behavioral skills in sexual risk reduction, suggesting these skills should be targeted in HIV prevention interventions. PMID:21638196

  13. Powerful model for the point source sky: Far-ultraviolet and enhanced midinfrared performance

    NASA Technical Reports Server (NTRS)

    Cohen, Martin

    1994-01-01

    I report further developments of the Wainscoat et al. (1992) model originally created for the point source infrared sky. The already detailed and realistic representation of the Galaxy (disk, spiral arms and local spur, molecular ring, bulge, spheroid) has been improved, guided by CO surveys of local molecular clouds, and by the inclusion of a component to represent Gould's Belt. The newest version of the model is very well validated by Infrared Astronomy Satellite (IRAS) source counts. A major new aspect is the extension of the same model down to the far ultraviolet. I compare predicted and observed far-utraviolet source counts from the Apollo 16 'S201' experiment (1400 A) and the TD1 satellite (for the 1565 A band).

  14. A novel ultrasound-guided shoulder arthroscopic surgery

    NASA Astrophysics Data System (ADS)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Chen, T.; Pichora, D.; Abolmaesumi, P.

    2006-03-01

    This paper presents a novel ultrasound-guided computer system for arthroscopic surgery of the shoulder joint. Intraoperatively, the system tracks and displays the surgical instruments, such as arthroscope and arthroscopic burrs, relative to the anatomy of the patient. The purpose of this system is to improve the surgeon's perception of the three-dimensional space within the anatomy of the patient in which the instruments are manipulated and to provide guidance towards the targeted anatomy. Pre-operatively, computed tomography images of the patient are acquired to construct virtual threedimensional surface models of the shoulder bone structure. Intra-operatively, live ultrasound images of pre-selected regions of the shoulder are captured using an ultrasound probe whose three-dimensional position is tracked by an optical camera. These images are used to register the surface model to the anatomy of the patient in the operating room. An initial alignment is obtained by matching at least three points manually selected on the model to their corresponding points identified on the ultrasound images. The registration is then improved with an iterative closest point or a sequential least squares estimation technique. In the present study the registration results of these techniques are compared. After the registration, surgical instruments are displayed relative to the surface model of the patient on a graphical screen visible to the surgeon. Results of laboratory experiments on a shoulder phantom indicate acceptable registration results and sufficiently fast overall system performance to be applicable in the operating room.

  15. The Effect of a Guide Field on Local Energy Conversion During Asymmetric Magnetic Reconnection: Particle-in-Cell Simulations

    NASA Astrophysics Data System (ADS)

    Cassak, P. A.; Genestreti, K. J.; Burch, J. L.; Phan, T.-D.; Shay, M. A.; Swisdak, M.; Drake, J. F.; Price, L.; Eriksson, S.; Ergun, R. E.; Anderson, B. J.; Merkin, V. G.; Komar, C. M.

    2017-11-01

    We use theory and simulations to study how the out-of-plane (guide) magnetic field strength modifies the location where the energy conversion rate between the electric field and the plasma is appreciable during asymmetric magnetic reconnection, motivated by observations (Genestreti et al., 2017). For weak guide fields, energy conversion is maximum on the magnetospheric side of the X line, midway between the X line and electron stagnation point. As the guide field increases, the electron stagnation point gets closer to the X line, and energy conversion occurs closer to the electron stagnation point. We motivate one possible nonrigorous approach to extend the theory of the stagnation point location to include a guide field. The predictions are compared to two-dimensional particle-in-cell (PIC) simulations with vastly different guide fields. The simulations have upstream parameters corresponding to three events observed with Magnetospheric Multiscale (MMS). The predictions agree reasonably well with the simulation results, capturing trends with the guide field. The theory correctly predicts that the X line and stagnation points approach each other as the guide field increases. The results are compared to MMS observations, Active Magnetosphere and Planetary Electrodynamics Response Experiment (AMPERE) observations of each event, and a global resistive-magnetohydrodynamics simulation of the 16 October 2015 event. The PIC simulation results agree well with the global observations and simulation but differ in the strong electric fields and energy conversion rates found in MMS observations. The observational, theoretical, and numerical results suggest that the strong electric fields observed by MMS do not represent a steady global reconnection rate.

  16. INPUFF: A SINGLE SOURCE GAUSSIAN PUFF DISPERSION ALGORITHM. USER'S GUIDE

    EPA Science Inventory

    INPUFF is a Gaussian INtegrated PUFF model. The Gaussian puff diffusion equation is used to compute the contribution to the concentration at each receptor from each puff every time step. Computations in INPUFF can be made for a single point source at up to 25 receptor locations. ...

  17. ELECTRON ACCELERATION IN CONTRACTING MAGNETIC ISLANDS DURING SOLAR FLARES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borovikov, D.; Tenishev, V.; Gombosi, T. I.

    Electron acceleration in solar flares is well known to be efficient at generating energetic particles that produce the observed bremsstrahlung X-ray spectra. One mechanism proposed to explain the observations is electron acceleration within contracting magnetic islands formed by magnetic reconnection in the flare current sheet. In a previous study, a numerical magnetohydrodynamic simulation of an eruptive solar flare was analyzed to estimate the associated electron acceleration due to island contraction. That analysis used a simple analytical model for the island structure and assumed conservation of the adiabatic invariants of particle motion. In this paper, we perform the first-ever rigorous integrationmore » of the guiding-center orbits of electrons in a modeled flare. An initially isotropic distribution of particles is seeded in a contracting island from the simulated eruption, and the subsequent evolution of these particles is followed using guiding-center theory. We find that the distribution function becomes increasingly anisotropic over time as the electrons’ energy increases by up to a factor of five, in general agreement with the previous study. In addition, we show that the energized particles are concentrated on the Sunward side of the island, adjacent to the reconnection X-point in the flare current sheet. Furthermore, our analysis demonstrates that the electron energy gain is dominated by betatron acceleration in the compressed, strengthened magnetic field of the contracting island. Fermi acceleration by the shortened field lines of the island also contributes to the energy gain, but it is less effective than the betatron process.« less

  18. A systematic review and meta-analysis of written self-administered psychosocial interventions among adults with a physical illness.

    PubMed

    Lambert, Sylvie D; Beatty, Lisa; McElduff, Patrick; Levesque, Janelle V; Lawsin, Catalina; Jacobsen, Paul; Turner, Jane; Girgis, Afaf

    2017-12-01

    The cost of implementing professionally-led psychosocial interventions has limited their integration into routine care. To enhance the translation of effective psychosocial interventions in routine care, a self-administered format is sometimes used. The meta-analysis examined the efficacy of written self-administered, psychosocial interventions to improve outcomes among individuals with a physical illness. Studies comparing a written self-administered intervention to a control group were identified through electronic databases searching. Pooled effect sizes were calculated across follow-up time points using random-effects models. Studies were also categorised according to three levels of guidance (self-administered, minimal contact, or guided) to examine the effect of this variable on outcomes. Forty manuscripts were retained for the descriptive review and 28 for the meta-analysis. Findings were significant for anxiety, depression, distress, and self-efficacy. Results were not significant for quality of life and related domains as well as coping. Purely self-administered interventions were efficacious for depression, distress, and self-efficacy; only guided interventions had an impact on anxiety. Findings showed that written self-administered interventions show promise across a number of outcomes. Self-administered interventions are a potentially efficacious and cost-effective approach to address some of the most common needs of patients with a physical illness. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Lung motion estimation using dynamic point shifting: An innovative model based on a robust point matching algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yi, Jianbing, E-mail: yijianbing8@163.com; Yang, Xuan, E-mail: xyang0520@263.net; Li, Yan-Ran, E-mail: lyran@szu.edu.cn

    2015-10-15

    Purpose: Image-guided radiotherapy is an advanced 4D radiotherapy technique that has been developed in recent years. However, respiratory motion causes significant uncertainties in image-guided radiotherapy procedures. To address these issues, an innovative lung motion estimation model based on a robust point matching is proposed in this paper. Methods: An innovative robust point matching algorithm using dynamic point shifting is proposed to estimate patient-specific lung motion during free breathing from 4D computed tomography data. The correspondence of the landmark points is determined from the Euclidean distance between the landmark points and the similarity between the local images that are centered atmore » points at the same time. To ensure that the points in the source image correspond to the points in the target image during other phases, the virtual target points are first created and shifted based on the similarity between the local image centered at the source point and the local image centered at the virtual target point. Second, the target points are shifted by the constrained inverse function mapping the target points to the virtual target points. The source point set and shifted target point set are used to estimate the transformation function between the source image and target image. Results: The performances of the authors’ method are evaluated on two publicly available DIR-lab and POPI-model lung datasets. For computing target registration errors on 750 landmark points in six phases of the DIR-lab dataset and 37 landmark points in ten phases of the POPI-model dataset, the mean and standard deviation by the authors’ method are 1.11 and 1.11 mm, but they are 2.33 and 2.32 mm without considering image intensity, and 1.17 and 1.19 mm with sliding conditions. For the two phases of maximum inhalation and maximum exhalation in the DIR-lab dataset with 300 landmark points of each case, the mean and standard deviation of target registration errors on the 3000 landmark points of ten cases by the authors’ method are 1.21 and 1.04 mm. In the EMPIRE10 lung registration challenge, the authors’ method ranks 24 of 39. According to the index of the maximum shear stretch, the authors’ method is also efficient to describe the discontinuous motion at the lung boundaries. Conclusions: By establishing the correspondence of the landmark points in the source phase and the other target phases combining shape matching and image intensity matching together, the mismatching issue in the robust point matching algorithm is adequately addressed. The target registration errors are statistically reduced by shifting the virtual target points and target points. The authors’ method with consideration of sliding conditions can effectively estimate the discontinuous motion, and the estimated motion is natural. The primary limitation of the proposed method is that the temporal constraints of the trajectories of voxels are not introduced into the motion model. However, the proposed method provides satisfactory motion information, which results in precise tumor coverage by the radiation dose during radiotherapy.« less

  20. Lung motion estimation using dynamic point shifting: An innovative model based on a robust point matching algorithm.

    PubMed

    Yi, Jianbing; Yang, Xuan; Chen, Guoliang; Li, Yan-Ran

    2015-10-01

    Image-guided radiotherapy is an advanced 4D radiotherapy technique that has been developed in recent years. However, respiratory motion causes significant uncertainties in image-guided radiotherapy procedures. To address these issues, an innovative lung motion estimation model based on a robust point matching is proposed in this paper. An innovative robust point matching algorithm using dynamic point shifting is proposed to estimate patient-specific lung motion during free breathing from 4D computed tomography data. The correspondence of the landmark points is determined from the Euclidean distance between the landmark points and the similarity between the local images that are centered at points at the same time. To ensure that the points in the source image correspond to the points in the target image during other phases, the virtual target points are first created and shifted based on the similarity between the local image centered at the source point and the local image centered at the virtual target point. Second, the target points are shifted by the constrained inverse function mapping the target points to the virtual target points. The source point set and shifted target point set are used to estimate the transformation function between the source image and target image. The performances of the authors' method are evaluated on two publicly available DIR-lab and POPI-model lung datasets. For computing target registration errors on 750 landmark points in six phases of the DIR-lab dataset and 37 landmark points in ten phases of the POPI-model dataset, the mean and standard deviation by the authors' method are 1.11 and 1.11 mm, but they are 2.33 and 2.32 mm without considering image intensity, and 1.17 and 1.19 mm with sliding conditions. For the two phases of maximum inhalation and maximum exhalation in the DIR-lab dataset with 300 landmark points of each case, the mean and standard deviation of target registration errors on the 3000 landmark points of ten cases by the authors' method are 1.21 and 1.04 mm. In the EMPIRE10 lung registration challenge, the authors' method ranks 24 of 39. According to the index of the maximum shear stretch, the authors' method is also efficient to describe the discontinuous motion at the lung boundaries. By establishing the correspondence of the landmark points in the source phase and the other target phases combining shape matching and image intensity matching together, the mismatching issue in the robust point matching algorithm is adequately addressed. The target registration errors are statistically reduced by shifting the virtual target points and target points. The authors' method with consideration of sliding conditions can effectively estimate the discontinuous motion, and the estimated motion is natural. The primary limitation of the proposed method is that the temporal constraints of the trajectories of voxels are not introduced into the motion model. However, the proposed method provides satisfactory motion information, which results in precise tumor coverage by the radiation dose during radiotherapy.

  1. Thermal APU/hydraulics analysis program. User's guide and programmer's manual

    NASA Technical Reports Server (NTRS)

    Deluna, T. A.

    1976-01-01

    The User's Guide information plus program description necessary to run and have a general understanding of the Thermal APU/Hydraulics Analysis Program (TAHAP) is described. This information consists of general descriptions of the APU/hydraulic system and the TAHAP model, input and output data descriptions, and specific subroutine requirements. Deck setups and input data formats are included and other necessary and/or helpful information for using TAHAP is given. The math model descriptions for the driver program and each of its supporting subroutines are outlined.

  2. The 3D Radiation Dose Analysis For Satellite

    NASA Astrophysics Data System (ADS)

    Cai, Zhenbo; Lin, Guocheng; Chen, Guozhen; Liu, Xia

    2002-01-01

    the earth. These particles come from the Van Allen Belt, Solar Cosmic Ray and Galaxy Cosmic Ray. They have different energy and flux, varying with time and space, and correlating with solar activity tightly. These particles interact with electrical components and materials used on satellites, producing various space radiation effects, which will damage satellite to some extent, or even affect its safety. orbit. Space energy particles inject into components and materials used on satellites, and generate radiation dose by depositing partial or entire energy in them through ionization, which causes their characteristic degradation or even failure. As a consequence, the analysis and protection for radiation dose has been paid more attention during satellite design and manufacture. Designers of satellites need to analyze accurately the space radiation dose while satellites are on orbit, and use the results as the basis for radiation protection designs and ground experiments for satellites. can be calculated, using the model of the trapped proton and the trapped electron in the Van Allen Belt (AE8 and AP8). This is the 1D radiation dose analysis for satellites. Obviously, the mass shielding from the outside space to the computed point in all directions is regarded as a simple sphere shell. The actual structure of satellites, however, is very complex. When energy particles are injecting into a given equipment inside satellite from outside space, they will travel across satellite structure, other equipment, the shell of the given equipment, and so on, which depends greatly on actual layout of satellite. This complex radiation shielding has two characteristics. One is that the shielding masses for the computed point are different in different injecting directions. The other is that for different computed points, the shielding conditions vary in all space directions. Therefore, it is very difficult to tell the differences described above using the 1D radiation analysis, and hence, it is too simple to guide satellite radiation protection and ground experiments only based on the 1D radiation analysis results. To comprehend the radiation dose status of satellite adequately, it's essential to perform 3D radiation analysis for satellites. using computer software. From this 3D layout, the satellite model can be simplified appropriately. First select the point to be analyzed in the simplified satellite model, and extend many lines to the outside space, which divides the 4 space into many corresponding small areas with a certain solid angle. Then the shielding masses through the satellite equipment and structures along each direction are calculated, resulting in the shielding mass distribution in all space directions based on the satellite layout. Finally, using the relationship between radiation dose and shielding thickness from the 1D analysis, calculate the radiation dose in each area represented by each line. After we obtain the radiation dose and its space distribution for the point of interest, the 3D satellite radiation analysis is completed. radiation analysis based on satellite 3D CAD layout has larger benefit for engineering applications than the 1D analysis based on the solid sphere shielding model. With the 3D model, the analysis of space environment and its effect is combined closely with actual satellite engineering. The 3D radiation analysis not only provides valuable engineering data for satellite radiation design and protection, but also provides possibility to apply new radiation protection approaches, which expands technology horizon and broadens ways for technology development.

  3. Cost-effectiveness of culture-guided antimicrobial prophylaxis for the prevention of infections after prostate biopsy.

    PubMed

    Li, Chi-Kong; Tong, Brian C Y; You, Joyce H S

    2016-02-01

    Clinical findings suggest that the use of rectal culture-guided antibiotic prophylaxis reduces the infection rate following transrectal ultrasound-guided prostate biopsy (TRUSBx). A decision-analytic model was designed to compare the outcomes of TRUSBx performed with (rectal culture-guided group) and without (standard ciprofloxacin prophylaxis) rectal swab culture-guided antimicrobial prophylaxis in Hong Kong. The post-biopsy infection rate, infection-related costs, quality-adjusted life years (QALYs) lost for infection, and incremental cost per QALY saved (ICER) were assessed. Model inputs were retrieved from local epidemiology data and the medical literature. A sensitivity analysis was performed to test the robustness of the model results. Base-case analysis showed that the infection rate in the culture-guided group was reduced from 2.42% to 0.23% and saved 0.0002 QALYs, with a lower cost (USD 31.4 versus USD 55.6) (USD 1=HKD 7.8). The number needed to screen to prevent an infection episode was 45.7. The hospital days avoided per 100 patients using culture-guided prophylaxis was 7.08 days. The relative effectiveness of culture-guided antimicrobial prophylaxis versus standard prophylaxis in carriers and non-carriers of FQ-resistant rectal flora were identified as potential influencing factors. In 10000 Monte Carlo simulations, ICERs of the culture-guided group were below the willingness-to-pay threshold 99.12% of the time. Using rectal culture-guided antimicrobial prophylaxis for men undergoing TRUSBx appears to be a cost-saving strategy to avert post-biopsy infection and QALY loss in Hong Kong. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. A prospective, randomized trial comparing the short- and long-term results of doppler-guided transanal hemorrhoid dearterialization with mucopexy versus excision hemorrhoidectomy for grade III hemorrhoids.

    PubMed

    De Nardi, Paola; Capretti, Giovanni; Corsaro, Antonino; Staudacher, Carlo

    2014-03-01

    Few randomized trials have compared the results of Doppler-guided transanal hemorrhoid dearterialization with mucopexy and excisional open hemorrhoidectomy. Few studies have reported long-term results. The aim of this study is to evaluate the results of Doppler-guided transanal hemorrhoid dearterialization with mucopexy compared with excisional open hemorrhoidectomy in patients with grade III hemorrhoids. This is a prospective randomized study registered at clinicaltrials.gov (NCT01263431). A power analysis assessed the study's sample size. Patients were randomly assigned to undergo either hemorrhoidectomy or Doppler-guided hemorrhoid dearterialization plus mucopexy. The χ test, Mann-Whitney U test, Student t test, and a regression model were used, as appropriate. This study was conducted at the Department of Surgery, San Raffaele Scientific Institute, Milan, Italy. Fifty consecutive patients were treated for grade III hemorrhoids from July to November 2010. The primary outcome was postoperative pain. The secondary outcomes included postoperative morbidity, the resumption of social and/or working activity, patient satisfaction, and the relapse of symptoms at 1 and 24 months. No major complications occurred in either group. The median visual analog scale scores for pain in the hemorrhoidectomy and Doppler-guided dearterialization plus mucopexy groups on days 1, 7, 14, and 30 were 7 vs 5.5, 3 vs 2.5, 1 vs 0, and 0 vs 0 (p> 0.05). The median work resumption day was the 22nd in the hemorrhoidectomy group and the 10th in the Doppler-guided dearterialization plus mucopexy group (p = 0.09). Patient satisfaction at 1 and 24 postoperative months, with the use of a 4-point scale, was 3 vs 4 and 4 vs 4 (p > 0.05). During the follow-up, 2 patients in the dearterialization group required ambulatory treatment, and 1 patient in each group required further surgery for symptom relapse. Nonvalidated questionnaires were used in the follow-up. Cost analysis was not performed. Compared with hemorrhoidectomy, dearterialization with mucopexy resulted in similar postoperative pain and morbidity, and a similar long-term cure rate.

  5. A metabolite-centric view on flux distributions in genome-scale metabolic models

    PubMed Central

    2013-01-01

    Background Genome-scale metabolic models are important tools in systems biology. They permit the in-silico prediction of cellular phenotypes via mathematical optimisation procedures, most importantly flux balance analysis. Current studies on metabolic models mostly consider reaction fluxes in isolation. Based on a recently proposed metabolite-centric approach, we here describe a set of methods that enable the analysis and interpretation of flux distributions in an integrated metabolite-centric view. We demonstrate how this framework can be used for the refinement of genome-scale metabolic models. Results We applied the metabolite-centric view developed here to the most recent metabolic reconstruction of Escherichia coli. By compiling the balance sheets of a small number of currency metabolites, we were able to fully characterise the energy metabolism as predicted by the model and to identify a possibility for model refinement in NADPH metabolism. Selected branch points were examined in detail in order to demonstrate how a metabolite-centric view allows identifying functional roles of metabolites. Fructose 6-phosphate aldolase and the sedoheptulose bisphosphate bypass were identified as enzymatic reactions that can carry high fluxes in the model but are unlikely to exhibit significant activity in vivo. Performing a metabolite essentiality analysis, unconstrained import and export of iron ions could be identified as potentially problematic for the quality of model predictions. Conclusions The system-wide analysis of split ratios and branch points allows a much deeper insight into the metabolic network than reaction-centric analyses. Extending an earlier metabolite-centric approach, the methods introduced here establish an integrated metabolite-centric framework for the interpretation of flux distributions in genome-scale metabolic networks that can complement the classical reaction-centric framework. Analysing fluxes and their metabolic context simultaneously opens the door to systems biological interpretations that are not apparent from isolated reaction fluxes. Particularly powerful demonstrations of this are the analyses of the complete metabolic contexts of energy metabolism and the folate-dependent one-carbon pool presented in this work. Finally, a metabolite-centric view on flux distributions can guide the refinement of metabolic reconstructions for specific growth scenarios. PMID:23587327

  6. Entropy production guides energy budget. Comment on ;Physics of metabolic organization; by Marko Jusup et al.

    NASA Astrophysics Data System (ADS)

    Martyushev, Leonid M.

    2017-03-01

    The paper [1] is very important and useful for everyone involved in mathematic modeling of biological processes. There is no point in mentioning here all the advantages of the publication because they can be found in the primary source itself. In this comment, I would like to briefly refer to the critical points that authors and readers may find useful for further consideration and development of the Dynamic Energy Budget (DEB) theory.

  7. MT3DMS: A Modular Three-Dimensional Multispecies Transport Model for Simulation of Advection, Dispersion, and Chemical Reactions of Contaminants in Groundwater Systems; Documentation and User’s Guide

    DTIC Science & Technology

    1999-12-01

    addition, the data files saved in the POINT format can include an optional header which is compatible with Amtec Engineering’s 2-D and 3-D visualization...34.DAT" file so that the file can be used directly by Amtec Engineering’s 2-D and 3-D visualization package Tecplot©. The ARRAY and POINT formats are

  8. ETA-MACRO: A user's guide

    NASA Astrophysics Data System (ADS)

    Manne, A. S.

    1981-02-01

    The ETA-MACRO model is designed to estimate the extent of two way linkage between the energy sector and the balance of the economy. It represents a merger between ETA (a process analysis for energy technology assessment) together with a macroeconomic growth model providing for substitution between capital, labor, and energy inputs. The ETA-MACRO allows explicitly for: (1) energy economy interactions; (2) cost effective conservation; (3) interfuel substitution, and (4) new supply technologies, each with its own difficulties and uncertainties on dates and rates of introduction. This user's guide includes an overview of the model, an illustrative application to long term US energy projections, and technical descriptions of the macro and ETA submodels. It also includes an analysis of how market penetration rates may be related to the profitability of new technologies. Finally, the appendices provide a detailed guide to the computer implementation.

  9. User's Guide for the Commercial Modular Aero-Propulsion System Simulation (C-MAPSS)

    NASA Technical Reports Server (NTRS)

    Frederick, Dean K.; DeCastro, Jonathan A.; Litt, Jonathan S.

    2007-01-01

    This report is a Users Guide for the NASA-developed Commercial Modular Aero-Propulsion System Simulation (C-MAPSS) software, which is a transient simulation of a large commercial turbofan engine (up to 90,000-lb thrust) with a realistic engine control system. The software supports easy access to health, control, and engine parameters through a graphical user interface (GUI). C-MAPSS provides the user with a graphical turbofan engine simulation environment in which advanced algorithms can be implemented and tested. C-MAPSS can run user-specified transient simulations, and it can generate state-space linear models of the nonlinear engine model at an operating point. The code has a number of GUI screens that allow point-and-click operation, and have editable fields for user-specified input. The software includes an atmospheric model which allows simulation of engine operation at altitudes from sea level to 40,000 ft, Mach numbers from 0 to 0.90, and ambient temperatures from -60 to 103 F. The package also includes a power-management system that allows the engine to be operated over a wide range of thrust levels throughout the full range of flight conditions.

  10. Noncontact point spectroscopy guided by two-channel fluorescence imaging in a hamster cheek pouch model

    NASA Astrophysics Data System (ADS)

    Yang, Victor X.; Yeow, Jenny; Lilge, Lothar D.; Kost, James; Mang, Thomas S.; Wilson, Brian C.

    1999-07-01

    A system for in vivo, fluorescence image-guided, non-contact point fluorescence spectroscopy is presented. A 442 nm HeCd laser is used as the fluorescence excitation source. An intensified CCD serves as the detector for both imaging and spectroscopy, on which two regions of 300 X 300 pixels were used for green (500 +/- 18 nm) and red (630 +/- 18 nm) imaging channels, and a strip of 600 X 120 pixels are used for emission spectroscopy (450 - 750 nm). At a working distance of 40 mm, the system has a spatial resolution of 0.16 mm and a spectral resolution of 5 nm. System performance is demonstrated in a carcinogenesis model in hamsters, where tumors were induced by painting DMBA in the cheek pouch. Autofluorescence and Photofrin-induced fluorescence measurements were performed every 2 weeks during the 18 weeks of tumor induction. Punch biopsies on selected animals were taken for histological staging. The results show that autofluorescence fluorescence can distinguish dysplasia from normal mucosal tissue model, utilizing the peak red intensity (or the red-to-green intensity ratio). Photofrin-induced fluorescence was superior to autofluorescence for differentiating high grade dysplasia from invasive cancer.

  11. Planning for the Future: Revealing Underrepresented Stories in the History of Physics and Astronomy

    NASA Astrophysics Data System (ADS)

    DiTomasso, Victoria; Spytek, Samantha; Neal, Stephen; Burch, Lance; Good, Gregory

    2017-01-01

    Women and minorities are, and have historically been, underrepresented in the physical sciences. This summer we wrote and revised over 40 teaching guides that highlight the often forgotten contributions of women and minorities to the physical sciences. Of these guides, 18 focus on astronomy/astrophysics specifically. We have ensured that these teaching guides meet national educational standards, fit well into social and natural science curricula, and are available for free online. They include lesson plans, worksheets, PowerPoints and readings. We intend for these resources to be easily integrated into classrooms from the first grade through the college level, and that they provide students with a diverse set of role models while also calling attention to ongoing diversity issues in STEM.

  12. Flow field investigation in a bulb turbine diffuser

    NASA Astrophysics Data System (ADS)

    Pereira, M.; Duquesne, P.; Aeschlimann, V.; Deschênes, C.

    2017-04-01

    An important drop in turbine performances has been measured in a bulb turbine model operated at overload. Previous investigations have correlated the performance drop with diffuser losses, and particularly to the flow separation zone at the diffuser wall. The flow has been investigated in the transition part of the diffuser using two LDV measurement sections. The transition part is a diffuser section that transforms from a circular to a rectangular section. The two measurement sections are at the inlet and outlet of the diffuser transition part. The turbine has been operated at three operating points, which are representative of different flow patterns at the diffuser exit at overload. In addition to the average velocity field, the analysis is conducted based on a backflow occurrence function and on the swirl level. Results reveal a counter-rotating zone in the diffuser, which intensifies with the guide vanes opening. The guide vanes opening induces a modification of the flow phenomena: from a central backflow recirculation zone at the lowest flowrate to a backflow zone induced by flow separation at the wall at the highest flowrate.

  13. Environmental Control of Root System Biology.

    PubMed

    Rellán-Álvarez, Rubén; Lobet, Guillaume; Dinneny, José R

    2016-04-29

    The plant root system traverses one of the most complex environments on earth. Understanding how roots support plant life on land requires knowing how soil properties affect the availability of nutrients and water and how roots manipulate the soil environment to optimize acquisition of these resources. Imaging of roots in soil allows the integrated analysis and modeling of environmental interactions occurring at micro- to macroscales. Advances in phenotyping of root systems is driving innovation in cross-platform-compatible methods for data analysis. Root systems acclimate to the environment through architectural changes that act at the root-type level as well as through tissue-specific changes that affect the metabolic needs of the root and the efficiency of nutrient uptake. A molecular understanding of the signaling mechanisms that guide local and systemic signaling is providing insight into the regulatory logic of environmental responses and has identified points where crosstalk between pathways occurs.

  14. R-SWAT-FME user's guide

    USGS Publications Warehouse

    Wu, Yiping; Liu, Shu-Guang

    2012-01-01

    R program language-Soil and Water Assessment Tool-Flexible Modeling Environment (R-SWAT-FME) (Wu and Liu, 2012) is a comprehensive modeling framework that adopts an R package, Flexible Modeling Environment (FME) (Soetaert and Petzoldt, 2010), for the Soil and Water Assessment Tool (SWAT) model (Arnold and others, 1998; Neitsch and others, 2005). This framework provides the functionalities of parameter identifiability, model calibration, and sensitivity and uncertainty analysis with instant visualization. This user's guide shows how to apply this framework for a customized SWAT project.

  15. Analysis of point-to-point lung motion with full inspiration and expiration CT data using non-linear optimization method: optimal geometric assumption model for the effective registration algorithm

    NASA Astrophysics Data System (ADS)

    Kim, Namkug; Seo, Joon Beom; Heo, Jeong Nam; Kang, Suk-Ho

    2007-03-01

    The study was conducted to develop a simple model for more robust lung registration of volumetric CT data, which is essential for various clinical lung analysis applications, including the lung nodule matching in follow up CT studies, semi-quantitative assessment of lung perfusion, and etc. The purpose of this study is to find the most effective reference point and geometric model based on the lung motion analysis from the CT data sets obtained in full inspiration (In.) and expiration (Ex.). Ten pairs of CT data sets in normal subjects obtained in full In. and Ex. were used in this study. Two radiologists were requested to draw 20 points representing the subpleural point of the central axis in each segment. The apex, hilar point, and center of inertia (COI) of each unilateral lung were proposed as the reference point. To evaluate optimal expansion point, non-linear optimization without constraints was employed. The objective function is sum of distances from the line, consist of the corresponding points between In. and Ex. to the optimal point x. By using the nonlinear optimization, the optimal points was evaluated and compared between reference points. The average distance between the optimal point and each line segment revealed that the balloon model was more suitable to explain the lung expansion model. This lung motion analysis based on vector analysis and non-linear optimization shows that balloon model centered on the center of inertia of lung is most effective geometric model to explain lung expansion by breathing.

  16. ACIRF user's guide: Theory and examples

    NASA Astrophysics Data System (ADS)

    Dana, Roger A.

    1989-12-01

    Design and evaluation of radio frequency systems that must operate through ionospheric disturbances resulting from high altitude nuclear detonations requires an accurate channel model. This model must include the effects of high gain antennas that may be used to receive the signals. Such a model can then be used to construct realizations of the received signal for use in digital simulations of trans-ionospheric links or for use in hardware channel simulators. The FORTRAN channel model ACIRF (Antenna Channel Impulse Response Function) generates random realizations of the impulse response function at the outputs of multiple antennas. This user's guide describes the FORTRAN program ACIRF (version 2.0) that generates realizations of channel impulse response functions at the outputs of multiple antennas with arbitrary beamwidths, pointing angles, and relatives positions. This channel model is valid under strong scattering conditions when Rayleigh fading statistics apply. Both frozen-in and turbulent models for the temporal fluctuations are included in this version of ACIRF. The theory of the channel model is described and several examples are given.

  17. Modeling timelines for translational science in cancer; the impact of technological maturation

    PubMed Central

    McNamee, Laura M.; Ledley, Fred D.

    2017-01-01

    This work examines translational science in cancer based on theories of innovation that posit a relationship between the maturation of technologies and their capacity to generate successful products. We examined the growth of technologies associated with 138 anticancer drugs using an analytical model that identifies the point of initiation of exponential growth and the point at which growth slows as the technology becomes established. Approval of targeted and biological products corresponded with technological maturation, with first approval averaging 14 years after the established point and 44 years after initiation of associated technologies. The lag in cancer drug approvals after the increases in cancer funding and dramatic scientific advances of the 1970s thus reflects predictable timelines of technology maturation. Analytical models of technological maturation may be used for technological forecasting to guide more efficient translation of scientific discoveries into cures. PMID:28346525

  18. Computation of wheel-rail contact force for non-mapping wheel-rail profile of Translohr tram

    NASA Astrophysics Data System (ADS)

    Ji, Yuanjin; Ren, Lihui; Zhou, Jinsong

    2017-09-01

    Translohr tram has steel wheels, in V-like arrangements, as guide wheels. These operate over the guide rails in inverted-V arrangements. However, the horizontal and vertical coordinates of the guide wheels and guide rails are not always mapped one-to-one. In this study, a simplified elastic method is proposed in order to calculate the contact points between the wheels and the rails. By transforming the coordinates, the non-mapping geometric relationship between wheel and rail is converted into a mapping relationship. Considering the Translohr tram's multi-point contact between the guide wheel and the guide rail, the elastic-contact hypothesis take into account the existence of contact patches between the bodies, and the location of the contact points is calculated using a simplified elastic method. In order to speed up the calculation, a multi-dimensional contact table is generated, enabling the use of simulation for Translohr tram running on curvatures with different radii.

  19. Using databases in medical education research: AMEE Guide No. 77.

    PubMed

    Cleland, Jennifer; Scott, Neil; Harrild, Kirsten; Moffat, Mandy

    2013-05-01

    This AMEE Guide offers an introduction to the use of databases in medical education research. It is intended for those who are contemplating conducting research in medical education but are new to the field. The Guide is structured around the process of planning your research so that data collection, management and analysis are appropriate for the research question. Throughout we consider contextual possibilities and constraints to educational research using databases, such as the resources available, and provide concrete examples of medical education research to illustrate many points. The first section of the Guide explains the difference between different types of data and classifying data, and addresses the rationale for research using databases in medical education. We explain the difference between qualitative research and qualitative data, the difference between categorical and quantitative data, and the difference types of data which fall into these categories. The Guide reviews the strengths and weaknesses of qualitative and quantitative research. The next section is structured around how to work with quantitative and qualitative databases and provides guidance on the many practicalities of setting up a database. This includes how to organise your database, including anonymising data and coding, as well as preparing and describing your data so it is ready for analysis. The critical matter of the ethics of using databases in medical educational research, including using routinely collected data versus data collected for research purposes, and issues of confidentiality, is discussed. Core to the Guide is drawing out the similarities and differences in working with different types of data and different types of databases. Future AMEE Guides in the research series will address statistical analysis of data in more detail.

  20. Assessing and Improving Student Organizations: Resources for Facilitators CD-ROM. The Assessing and Improving Student Organization (AISO) Program

    ERIC Educational Resources Information Center

    Nolfi, Tricia; Ruben, Brent D.

    2010-01-01

    This companion to the "Guide for Students" and "Student Workbook" includes the complete set of PowerPoint slides, a PDF of the Facilitator's Guide in PPT (PowerPoint) slide show format, and PDFs of all scoring sheets, handouts and project planning guides needed for the AISO (Assessing and Improving Student Organization) process. The Assessing and…

  1. Scenario Analysis: An Integrative Study and Guide to Implementation in the United States Air Force

    DTIC Science & Technology

    1994-09-01

    Environmental Analysis ................................ 3-3 Classifications of Environments ......................... 3-5 Characteristics of... Environments ........................ 3-8 iii Page Components of the Environmental Analysis Process ........... 3-12 Forecasting... Environmental Analysis ...................... 3-4 3-2 Model of the Industry Environment ......................... 3-6 3-3 Model of Macroenvironment

  2. B-Mode ultrasound pose recovery via surgical fiducial segmentation and tracking

    NASA Astrophysics Data System (ADS)

    Asoni, Alessandro; Ketcha, Michael; Kuo, Nathanael; Chen, Lei; Boctor, Emad; Coon, Devin; Prince, Jerry L.

    2015-03-01

    Ultrasound Doppler imaging may be used to detect blood clots after surgery, a common problem. However, this requires consistent probe positioning over multiple time instances and therefore significant sonographic expertise. Analysis of ultrasound B-mode images of a fiducial implanted at the surgical site offers a landmark to guide a user to the same location repeatedly. We demonstrate that such an implanted fiducial may be successfully detected and tracked to calculate pose and guide a clinician consistently to the site of surgery, potentially reducing the ultrasound experience required for point of care monitoring.

  3. Stroke Self-efficacy Questionnaire: a Rasch-refined measure of confidence post stroke.

    PubMed

    Riazi, Afsane; Aspden, Trefor; Jones, Fiona

    2014-05-01

    Measuring self-efficacy during rehabilitation provides an important insight into understanding recovery post stroke. A Rasch analysis of the Stroke Self-efficacy Questionnaire (SSEQ) was undertaken to establish its use as a clinically meaningful and scientifically rigorous measure. One hundred and eighteen stroke patients completed the SSEQ with the help of an interviewer. Participants were recruited from local acute stroke units and community stroke rehabilitation teams. Data were analysed with confirmatory factor analysis conducted using AMOS and Rasch analysis conducted using RUMM2030 software. Confirmatory factor analysis and Rasch analyses demonstrated the presence of two separate scales that measure stroke survivors' self-efficacy with: i) self-management and ii) functional activities. Guided by Rasch analyses, the response categories of these two scales were collapsed from an 11-point to a 4-point scale. Modified scales met the expectations of the Rasch model. Items satisfied the Rasch requirements (overall and individual item fit, local response independence, differential item functioning, unidimensionality). Furthermore, the two subscales showed evidence of good construct validity. The new SSEQ has good psychometric properties and is a clinically useful assessment of self-efficacy after stroke. The scale measures stroke survivors' self-efficacy with self-management and activities as two unidimensional constructs. It is recommended for use in clinical and research interventions, and in evaluating stroke self-management interventions.

  4. Graph-based analysis of connectivity in spatially-explicit population models: HexSim and the Connectivity Analysis Toolkit

    EPA Science Inventory

    Background / Question / Methods Planning for the recovery of threatened species is increasingly informed by spatially-explicit population models. However, using simulation model results to guide land management decisions can be difficult due to the volume and complexity of model...

  5. Visible and infrared spin scanning radiometer /VISSR/ atmospheric sounder /VAS/ ground data system

    NASA Astrophysics Data System (ADS)

    Dalton, J. T.; Jamros, R. K.; Helfer, D. P.; Howell, D. R.

    1981-01-01

    The interactive system developed at NASA/Goddard Space Flight Center to receive data from the infrared radiometer on GOES-4 in near real time and to perform interactive display and analysis of the 12-channel infrared imagery is described. The system is minicomputer based and uses a menu approach in guiding the analyst through spacecraft instrument programming, area and band selection, image acquisition, enhancement, analysis, and presentation of results. The system is linked by dual port disks to Goddard's Atmospheric and Oceanographic Information Processing System for comparing the sounding results with parameters derived from conventional data and from time lapse analysis of visible and IR imagery from other geostationary satellites. It is pointed out that the system hardware and software are being expanded to add capabilities for the integration and assimilation of VAS data with data from other sources, the comparison of severe storm observations from space with special ground network data, and the development of diagnostic models.

  6. Smart travel guide: from internet image database to intelligent system

    NASA Astrophysics Data System (ADS)

    Chareyron, Ga"l.; Da Rugna, Jérome; Cousin, Saskia

    2011-02-01

    To help the tourist to discover a city, a region or a park, many options are provided by public tourism travel centers, by free online guides or by dedicated book guides. Nonetheless, these guides provide only mainstream information which are not conform to a particular tourist behavior. On the other hand, we may find several online image databases allowing users to upload their images and to localize each image on a map. These websites are representative of tourism practices and constitute a proxy to analyze tourism flows. Then, this work intends to answer this question: knowing what I have visited and what other people have visited, where should I go now? This process needs to profile users, sites and photos. our paper presents the acquired data and relationship between photographers, sites and photos and introduces the model designed to correctly estimate the site interest of each tourism point. The third part shows an application of our schema: a smart travel guide on geolocated mobile devices. This android application is a travel guide truly matching the user wishes.

  7. The Indirect Effects of Maternal Emotion Socialization on Friendship Quality in Middle Childhood

    PubMed Central

    Blair, Bethany L.; Perry, Nicole B.; O’Brien, Marion; Calkins, Susan D.; Keane, Susan P.; Shanahan, Lilly

    2014-01-01

    Emotion development processes have long been linked to social competence in early childhood but rarely have these associations been examined in middle childhood or with relational outcomes. Guided by theories of interpersonal relationships and emotion socialization, the current study was designed to fill these gaps by examining a longitudinal process model indirectly linking emotion development to friendship quality. Data were drawn from 336 children (179 girls, 65% White), their mothers, and their teachers across 3 time points spanning the ages of 5–10 years. A path analysis model was utilized to examine the way in which maternal emotion socialization indirectly affects children’s friendship quality. Results supported the hypothesized model in which maternal emotion socialization strategies used when children were age 5 were associated with changes in friendship quality from ages 7 to 10 via changes in children’s emotion regulation. Findings highlight the importance of emotional processes for relational outcomes in middle childhood. PMID:23795555

  8. Space Generic Open Avionics Architecture (SGOAA) reference model technical guide

    NASA Technical Reports Server (NTRS)

    Wray, Richard B.; Stovall, John R.

    1993-01-01

    This report presents a full description of the Space Generic Open Avionics Architecture (SGOAA). The SGOAA consists of a generic system architecture for the entities in spacecraft avionics, a generic processing architecture, and a six class model of interfaces in a hardware/software system. The purpose of the SGOAA is to provide an umbrella set of requirements for applying the generic architecture interface model to the design of specific avionics hardware/software systems. The SGOAA defines a generic set of system interface points to facilitate identification of critical interfaces and establishes the requirements for applying appropriate low level detailed implementation standards to those interface points. The generic core avionics system and processing architecture models provided herein are robustly tailorable to specific system applications and provide a platform upon which the interface model is to be applied.

  9. Alzheimer disease in a mouse model: MR imaging-guided focused ultrasound targeted to the hippocampus opens the blood-brain barrier and improves pathologic abnormalities and behavior.

    PubMed

    Burgess, Alison; Dubey, Sonam; Yeung, Sharon; Hough, Olivia; Eterman, Naomi; Aubert, Isabelle; Hynynen, Kullervo

    2014-12-01

    To validate whether repeated magnetic resonance (MR) imaging-guided focused ultrasound treatments targeted to the hippocampus, a brain structure relevant for Alzheimer disease ( AD Alzheimer disease ), could modulate pathologic abnormalities, plasticity, and behavior in a mouse model. All animal procedures were approved by the Animal Care Committee and are in accordance with the Canadian Council on Animal Care. Seven-month-old transgenic (TgCRND8) (Tg) mice and their nontransgenic (non-Tg) littermates were entered in the study. Mice were treated weekly with MR imaging-guided focused ultrasound in the bilateral hippocampus (1.68 MHz, 10-msec bursts, 1-Hz burst repetition frequency, 120-second total duration). After 1 month, spatial memory was tested in the Y maze with the novel arm prior to sacrifice and immunohistochemical analysis. The data were compared by using unpaired t tests and analysis of variance with Tukey post hoc analysis. Untreated Tg mice spent 61% less time than untreated non-Tg mice exploring the novel arm of the Y maze because of spatial memory impairments (P < .05). Following MR imaging-guided focused ultrasound, Tg mice spent 99% more time exploring the novel arm, performing as well as their non-Tg littermates. Changes in behavior were correlated with a reduction of the number and size of amyloid plaques in the MR imaging-guided focused ultrasound-treated animals (P < .01). Further, after MR imaging-guided focused ultrasound treatment, there was a 250% increase in the number of newborn neurons in the hippocampus (P < .01). The newborn neurons had longer dendrites and more arborization after MR imaging-guided focused ultrasound, as well (P < .01). Repeated MR imaging-guided focused ultrasound treatments led to spatial memory improvement in a Tg mouse model of AD Alzheimer disease . The behavior changes may be mediated by decreased amyloid pathologic abnormalities and increased neuronal plasticity. © RSNA, 2014.

  10. An Analysis of Modifications to the Three-Step Guided Compliance Procedure Necessary to Achieve Compliance among Preschool Children

    ERIC Educational Resources Information Center

    Wilder, David A.; Myers, Kristin; Fischetti, Anthony; Leon, Yanerys; Nicholson, Katie; Allison, Janelle

    2012-01-01

    After a 3-step guided compliance procedure (vocal prompt, vocal plus model prompt, vocal prompt plus physical guidance) did not increase compliance, we evaluated 2 modifications with 4 preschool children who exhibited noncompliance. The first modification consisted of omission of the model prompt, and the second modification consisted of omitting…

  11. A User's Guide for the Differential Reduced Ejector/Mixer Analysis "DREA" Program. 1.0

    NASA Technical Reports Server (NTRS)

    DeChant, Lawrence J.; Nadell, Shari-Beth

    1999-01-01

    A system of analytical and numerical two-dimensional mixer/ejector nozzle models that require minimal empirical input has been developed and programmed for use in conceptual and preliminary design. This report contains a user's guide describing the operation of the computer code, DREA (Differential Reduced Ejector/mixer Analysis), that contains these mathematical models. This program is currently being adopted by the Propulsion Systems Analysis Office at the NASA Glenn Research Center. A brief summary of the DREA method is provided, followed by detailed descriptions of the program input and output files. Sample cases demonstrating the application of the program are presented.

  12. Analysis of point source size on measurement accuracy of lateral point-spread function of confocal Raman microscopy

    NASA Astrophysics Data System (ADS)

    Fu, Shihang; Zhang, Li; Hu, Yao; Ding, Xiang

    2018-01-01

    Confocal Raman Microscopy (CRM) has matured to become one of the most powerful instruments in analytical science because of its molecular sensitivity and high spatial resolution. Compared with conventional Raman Microscopy, CRM can perform three dimensions mapping of tiny samples and has the advantage of high spatial resolution thanking to the unique pinhole. With the wide application of the instrument, there is a growing requirement for the evaluation of the imaging performance of the system. Point-spread function (PSF) is an important approach to the evaluation of imaging capability of an optical instrument. Among a variety of measurement methods of PSF, the point source method has been widely used because it is easy to operate and the measurement results are approximate to the true PSF. In the point source method, the point source size has a significant impact on the final measurement accuracy. In this paper, the influence of the point source sizes on the measurement accuracy of PSF is analyzed and verified experimentally. A theoretical model of the lateral PSF for CRM is established and the effect of point source size on full-width at half maximum of lateral PSF is simulated. For long-term preservation and measurement convenience, PSF measurement phantom using polydimethylsiloxane resin, doped with different sizes of polystyrene microspheres is designed. The PSF of CRM with different sizes of microspheres are measured and the results are compared with the simulation results. The results provide a guide for measuring the PSF of the CRM.

  13. A simple weighted scoring system to guide surgical decision-making in patients with parapneumonic pleural effusion.

    PubMed

    Chang, Che-Chia; Chen, Tzu-Ping; Yeh, Chi-Hsiao; Huang, Pin-Fu; Wang, Yao-Chang; Yin, Shun-Ying

    2016-11-01

    The selection of ideal candidates for surgical intervention among patients with parapneumonic pleural effusion remains challenging. In this retrospective study, we sought to identify the main predictors of surgical treatment and devise a simple scoring system to guide surgical decision-making. Between 2005 and 2014, we identified 276 patients with parapneumonic pleural effusion. Patients in the training set (n=201) were divided into two groups according to their treatment modality (non-surgery vs. surgery). Using multivariable logistic regression analysis, we devised a scoring system to guide surgical decision-making. The score was subsequently validated in an independent set of 75 patients. A white blood cell count >13,500/µL, pleuritic pain, loculations, and split pleura sign were identified as independent predictors of surgical treatment. A weighted score based on these factors was devised, as follows: white blood cell count >13,500/µL (one point), pleuritic pain (one point), loculations (two points), and split pleura sign (three points). A score >4 was associated with a surgical approach with a sensitivity of 93.4%, a specificity of 82.4%, and an area under curve (AUC) of 0.879 (95% confidence interval: 0.828-0.930). In the validation set, a sensitivity of 94.3% and a specificity of 79.6% were found (AUC=0.869). The proposed scoring system reliably identifies patients with parapneumonic pleural effusion who are candidates for surgery. Pending independent external validation, our score may inform the appropriate use of surgical interventions in this clinical setting.

  14. User's Guide To CHEAP0 II-Economic Analysis of Stand Prognosis Model Outputs

    Treesearch

    Joseph E. Horn; E. Lee Medema; Ervin G. Schuster

    1986-01-01

    CHEAP0 II provides supplemental economic analysis capability for users of version 5.1 of the Stand Prognosis Model, including recent regeneration and insect outbreak extensions. Although patterned after the old CHEAP0 model, CHEAP0 II has more features and analytic capabilities, especially for analysis of existing and uneven-aged stands....

  15. ECONOMIC GROWTH ANALYSIS SYSTEM: USER'S GUIDE

    EPA Science Inventory

    The two-volume report describes the development of, and provides information needed to operate, a prototype Economic Growth Analysis System (E-GAS) modeling system. The model will be used to project emissions inventories of volatile organic compounds (VOCs), oxides of nitrogen (...

  16. Feasibility study for image guided kidney surgery: assessment of required intraoperative surface for accurate image to physical space registrations

    NASA Astrophysics Data System (ADS)

    Benincasa, Anne B.; Clements, Logan W.; Herrell, S. Duke; Chang, Sam S.; Cookson, Michael S.; Galloway, Robert L.

    2006-03-01

    Currently, the removal of kidney tumor masses uses only direct or laparoscopic visualizations, resulting in prolonged procedure and recovery times and reduced clear margin. Applying current image guided surgery (IGS) techniques, as those used in liver cases, to kidney resections (nephrectomies) presents a number of complications. Most notably is the limited field of view of the intraoperative kidney surface, which constrains the ability to obtain a surface delineation that is geometrically descriptive enough to drive a surface-based registration. Two different phantom orientations were used to model the laparoscopic and traditional partial nephrectomy views. For the laparoscopic view, fiducial point sets were compiled from a CT image volume using anatomical features such as the renal artery and vein. For the traditional view, markers attached to the phantom set-up were used for fiducials and targets. The fiducial points were used to perform a point-based registration, which then served as a guide for the surface-based registration. Laser range scanner (LRS) obtained surfaces were registered to each phantom surface using a rigid iterative closest point algorithm. Subsets of each phantom's LRS surface were used in a robustness test to determine the predictability of their registrations to transform the entire surface. Results from both orientations suggest that about half of the kidney's surface needs to be obtained intraoperatively for accurate registrations between the image surface and the LRS surface, suggesting the obtained kidney surfaces were geometrically descriptive enough to perform accurate registrations. This preliminary work paves the way for further development of kidney IGS systems.

  17. Ultrasonic guided wave propagation across waveguide transitions: energy transfer and mode conversion.

    PubMed

    Puthillath, Padmakumar; Galan, Jose M; Ren, Baiyang; Lissenden, Cliff J; Rose, Joseph L

    2013-05-01

    Ultrasonic guided wave inspection of structures containing adhesively bonded joints requires an understanding of the interaction of guided waves with geometric and material discontinuities or transitions in the waveguide. Such interactions result in mode conversion with energy being partitioned among the reflected and transmitted modes. The step transition between an aluminum layer and an aluminum-adhesive-aluminum multi-layer waveguide is analyzed as a model structure. Dispersion analysis enables assessment of (i) synchronism through dispersion curve overlap and (ii) wavestructure correlation. Mode-pairs in the multi-layer waveguide are defined relative to a prescribed mode in a single layer as being synchronized and having nearly perfect wavestructure matching. Only a limited number of mode-pairs exist, and each has a unique frequency range. A hybrid model based on semi-analytical finite elements and the normal mode expansion is implemented to assess mode conversion at a step transition in a waveguide. The model results indicate that synchronism and wavestructure matching is associated with energy transfer through the step transition, and that the energy of an incident wave mode in a single layer is transmitted almost entirely to the associated mode-pair, where one exists. This analysis guides the selection of incident modes that convert into transmitted modes and improve adhesive joint inspection with ultrasonic guided waves.

  18. A magnetic resonance image-guided breast needle intervention robot system: overview and design considerations.

    PubMed

    Park, Samuel Byeongjun; Kim, Jung-Gun; Lim, Ki-Woong; Yoon, Chae-Hyun; Kim, Dong-Jun; Kang, Han-Sung; Jo, Yung-Ho

    2017-08-01

    We developed an image-guided intervention robot system that can be operated in a magnetic resonance (MR) imaging gantry. The system incorporates a bendable needle intervention robot for breast cancer patients that overcomes the space limitations of the MR gantry. Most breast coil designs for breast MR imaging have side openings to allow manual localization. However, for many intervention procedures, the patient must be removed from the gantry. A robotic manipulation system with integrated image guidance software was developed. Our robotic manipulator was designed to be slim, so as to fit between the patient's side and the MR gantry wall. Only non-magnetic materials were used, and an electromagnetic shield was employed for cables and circuits. The image guidance software was built using open source libraries. In situ feasibility tests were performed in a 3-T MR system. One target point in the breast phantom was chosen by the clinician for each experiment, and our robot moved the needle close to the target point. Without image-guided feedback control, the needle end could not hit the target point (distance = 5 mm) in the first experiment. Using our robotic system, the needle hits the target lesion of the breast phantom at a distance of 2.3 mm from the same target point using image-guided feedback. The second experiment was performed using other target points, and the distance between the final needle end point and the target point was 0.8 mm. We successfully developed an MR-guided needle intervention robot for breast cancer patients. Further research will allow the expansion of these interventions.

  19. Cost Effectiveness of the Instrumentalism in Occupational Therapy (IOT) Conceptual Model as a Guide for Intervention with Adolescents with Emotional and Behavioral Disorders (EBD)

    ERIC Educational Resources Information Center

    Ikiugu, Moses N.; Anderson, Lynne

    2007-01-01

    The purpose of this paper was to demonstrate the cost-effectiveness of using the Instrumentalism in Occupational Therapy (IOT) conceptual practice model as a guide for intervention to assist teenagers with emotional and behavioral disorders (EBD) transition successfully into adulthood. The cost effectiveness analysis was based on a project…

  20. Predictions of Experimentally Observed Stochastic Ground Vibrations Induced by Blasting

    PubMed Central

    Kostić, Srđan; Perc, Matjaž; Vasović, Nebojša; Trajković, Slobodan

    2013-01-01

    In the present paper, we investigate the blast induced ground motion recorded at the limestone quarry “Suva Vrela” near Kosjerić, which is located in the western part of Serbia. We examine the recorded signals by means of surrogate data methods and a determinism test, in order to determine whether the recorded ground velocity is stochastic or deterministic in nature. Longitudinal, transversal and the vertical ground motion component are analyzed at three monitoring points that are located at different distances from the blasting source. The analysis reveals that the recordings belong to a class of stationary linear stochastic processes with Gaussian inputs, which could be distorted by a monotonic, instantaneous, time-independent nonlinear function. Low determinism factors obtained with the determinism test further confirm the stochastic nature of the recordings. Guided by the outcome of time series analysis, we propose an improved prediction model for the peak particle velocity based on a neural network. We show that, while conventional predictors fail to provide acceptable prediction accuracy, the neural network model with four main blast parameters as input, namely total charge, maximum charge per delay, distance from the blasting source to the measuring point, and hole depth, delivers significantly more accurate predictions that may be applicable on site. We also perform a sensitivity analysis, which reveals that the distance from the blasting source has the strongest influence on the final value of the peak particle velocity. This is in full agreement with previous observations and theory, thus additionally validating our methodology and main conclusions. PMID:24358140

  1. A Performance-Based Training Qualification Guide/Checklist Developed for Reactor Operators at the High Flux Beam Reactor at Brookhaven National Laboratory.

    ERIC Educational Resources Information Center

    McNair, Robert C.

    A Performance-Based Training (PBT) Qualification Guide/Checklist was developed that would enable a trainee to attain the skills, knowledge, and attitude required to operate the High Flux Beam Reactor at Brookhaven National Laboratory. Design of this guide/checklist was based on the Instructional System Design Model. The needs analysis identified…

  2. Utilization of a cognitive task analysis for laparoscopic appendectomy to identify differentiated intraoperative teaching objectives.

    PubMed

    Smink, Douglas S; Peyre, Sarah E; Soybel, David I; Tavakkolizadeh, Ali; Vernon, Ashley H; Anastakis, Dimitri J

    2012-04-01

    Experts become automated when performing surgery, making it difficult to teach complex procedures to trainees. Cognitive task analysis (CTA) enables experts to articulate operative steps and cognitive decisions in complex procedures such as laparoscopic appendectomy, which can then be used to identify central teaching points. Three local surgeon experts in laparoscopic appendectomy were interviewed using critical decision method-based CTA methodology. Interview transcripts were analyzed, and a cognitive demands table (CDT) was created for each expert. The individual CDTs were reviewed by each expert for completeness and then combined into a master CDT. Percentage agreement on operative steps and decision points was calculated for each expert. The experts then participated in a consensus meeting to review the master CDT. Each surgeon expert was asked to identify in the master CDT the most important teaching objectives for junior-level and senior-level residents. The experts' responses for junior-level and senior-level residents were compared using a χ(2) test. The surgeon experts identified 24 operative steps and 27 decision points. Eighteen of the 24 operative steps (75%) were identified by all 3 surgeon experts. The percentage of operative steps identified was high for each surgeon expert (96% for surgeon 1, 79% for surgeon 2, and 83% for surgeon 3). Of the 27 decision points, only 5 (19%) were identified by all 3 surgeon experts. The percentage of decision points identified varied by surgeon expert (78% for surgeon 1, 59% for surgeon 2, and 48% for surgeon 3). When asked to identify key teaching points, the surgeon experts were more likely to identify operative steps for junior residents (9 operative steps and 6 decision points) and decision points for senior residents (4 operative steps and 13 decision points) (P < .01). CTA can deconstruct the essential operative steps and decision points associated with performing a laparoscopic appendectomy. These results provide a framework to identify key teaching principles to guide intraoperative instruction. These learning objectives could be used to guide resident level-appropriate teaching of an essential general surgery procedure. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Statewide Dissemination of a Rural, Non-Chain Restaurant Intervention: Adoption, Implementation and Maintenance

    ERIC Educational Resources Information Center

    Nothwehr, F.; Haines, H.; Chrisman, M.; Schultz, U.

    2014-01-01

    The obesity epidemic calls for greater dissemination of nutrition-related programs, yet there remain few studies of the dissemination process. This study, guided by elements of the RE-AIM model, describes the statewide dissemination of a simple, point-of-purchase restaurant intervention. Conducted in rural counties of the Midwest, United States,…

  4. Faculty Opinions Regarding the Philosophical Principles of Total Quality Management (TQM).

    ERIC Educational Resources Information Center

    Aliff, John Vincent

    The 14 points of the Total Quality Management (TQM) model can be distilled into the following 5 main guiding principles: establish a moral purpose for the institution, use cooperative efforts instead of individual efforts, stop the use of inspection (testing) to improve students and teachers, continuously improve the system and its products, and…

  5. Social Change and Individual Change--Developmental Science as Guide Post

    ERIC Educational Resources Information Center

    Silbereisen, Rainer K.

    2012-01-01

    From a biopsychosocial perspective on human development, this essay review introduces a model linking social changes at the macro level with individual development at the micro level. German unification and the globalization of economy that followed are taken as a case in point for social changes that have affected the lives of many. It is argued…

  6. [Comparison of self-controlled retruded approach and bimanual manipulation method on the relationship of incisal point displacement in the mandibular retruded contact position].

    PubMed

    Zhang, Lei; Li, Yun-xia; Kang, Yan-feng; Yang, Guang-ju; Xie, Qiu-fei

    2014-02-18

    To evaluate the relationship of incisal point displacements in the mandibular retruded contact position (RCP) between the self-controlled retruded approach and bimanual manipulation method. Twelve healthy young volunteers were selected. The RCP was guided through the self-controlled retruded approach and bimanual manipulation method. The track of the incisal point was recorded, using the mandibular movement trace recording system. The movement direction of the incisal point in horizontal plane was observed. The distance between the incisal point of the RCP and intercuspal contact position (ICP) was measured. Except one volunteer's incisal point movement direction of the RCP was oblique, others were straight toward posterior. The displacements of the incisal point from the ICP to RCP guided through self-controlled approach and bimanual manipulation method were (1.15 ± 0.64) mm, (0.98 ± 0.29) mm respectively. There was no statistical significance between the two methods (P > 0.05). The displacements of the incisal point from the ICP to RCP guided through self-controlled approach and bimanual manipulation method are approximately the same.

  7. iBoard/CDX User Guide for Nonfederal Individuals and Company/Organization Points of Contact

    EPA Pesticide Factsheets

    This user guide describes the process that individuals or company/organization points of contact (POCs) must follow to submit non-EPA personnel data through the EPA’s Central Data Exchange (CDX) iBoard application for review and approval.

  8. Analysis Tools for CFD Multigrid Solvers

    NASA Technical Reports Server (NTRS)

    Mineck, Raymond E.; Thomas, James L.; Diskin, Boris

    2004-01-01

    Analysis tools are needed to guide the development and evaluate the performance of multigrid solvers for the fluid flow equations. Classical analysis tools, such as local mode analysis, often fail to accurately predict performance. Two-grid analysis tools, herein referred to as Idealized Coarse Grid and Idealized Relaxation iterations, have been developed and evaluated within a pilot multigrid solver. These new tools are applicable to general systems of equations and/or discretizations and point to problem areas within an existing multigrid solver. Idealized Relaxation and Idealized Coarse Grid are applied in developing textbook-efficient multigrid solvers for incompressible stagnation flow problems.

  9. Development and Present Situation Analysis of Power Transformer State Maintenance

    NASA Astrophysics Data System (ADS)

    Lv, Sen; Li, Biao; Li, Huan

    2018-02-01

    The pivotal status of power transformer in the power system is one of the most important equipment. The safety and reliability of its operation is directly related to the safety and stability of power system. Based on the analysis of the present situation of power transformer state maintenance in home and abroad. The paper points out the deficiency of the current method and provides a theoretical basis for further research, which has a certain guiding significance.

  10. Radiologic Analysis and Clinical Study of the Upper One-third Joint Technique for Fluoroscopically Guided Sacroiliac Joint Injection.

    PubMed

    Park, Junghyun; Park, Hue Jung; Moon, Dong Eon; Sa, Gye Jeol; Kim, Young Hoon

    2015-01-01

    Sacroiliac intraarticular injection by the traditional technique can be challenging to perform when the joint is covered with osteophytes or is extremely narrow. To examine whether there is enough space for the needle to be advanced from the L5-S1 interspinous space to the upper one-third sacroiliac joint (SIJ) by magnetic resonance image (MRI) analysis as an alternative to fluoroscopically guided SIJ injection with the lower one-third joint technique, and to determine the feasibility of this novel technique in clinical practice. MRI analysis and observational study. An interventional pain management practice at a university hospital. We analyzed 200 axial T2-weighted MRIs between the L5 and S1 vertebrae of 100 consecutive patients. The following measurements were obtained on both sides: 1) the thickness of fat in the midline; 2) the distance between the midline (Point C) and the junction (Point A) of the skin and the imaginary line that connects the SIJ and the most medial cortex of the ilium; 3) the distance between the midline (Point C) and the junction (Point B) of the skin and the imaginary line that connects the SIJ and the L5 spinous process; 4) the distance between the SIJ and midline (Point C) on the skin, or between the SIJ and the midpoint (Point C') of the line from Point A to Point B; and 5) the angle between the sagittal line and the imaginary line that connects the SIJ and the midline on the skin. The upper one-third joint technique was performed to establish the feasibility of the alternative technique in 20 patients who had unsuccessful sacroiliac intraarticular injections using the lower one-third joint technique. The mean distances from the midline to Point A and to Point B were 21.9 ± 13.7 mm and 27.8 ± 13.6 mm, respectively. The mean distance between the SIJ and Point C (or Point C') was 81.0 ± 13.3 mm. The angle between the sagittal line and the imaginary line that connects the SIJ and the midline on the skin was 42.8 ± 5.1°. The success rate of sacroiliac intraarticular injections with the upper one-third joint technique was 90% (18/20). This was an observational study and lacked a control group. Sacroiliac intraarticular injections with the upper one-third joint technique are advisable when it is hard to perform them with the lower one-third joint technique.

  11. Foveal analysis and peripheral selection during active visual sampling

    PubMed Central

    Ludwig, Casimir J. H.; Davies, J. Rhys; Eckstein, Miguel P.

    2014-01-01

    Human vision is an active process in which information is sampled during brief periods of stable fixation in between gaze shifts. Foveal analysis serves to identify the currently fixated object and has to be coordinated with a peripheral selection process of the next fixation location. Models of visual search and scene perception typically focus on the latter, without considering foveal processing requirements. We developed a dual-task noise classification technique that enables identification of the information uptake for foveal analysis and peripheral selection within a single fixation. Human observers had to use foveal vision to extract visual feature information (orientation) from different locations for a psychophysical comparison. The selection of to-be-fixated locations was guided by a different feature (luminance contrast). We inserted noise in both visual features and identified the uptake of information by looking at correlations between the noise at different points in time and behavior. Our data show that foveal analysis and peripheral selection proceeded completely in parallel. Peripheral processing stopped some time before the onset of an eye movement, but foveal analysis continued during this period. Variations in the difficulty of foveal processing did not influence the uptake of peripheral information and the efficacy of peripheral selection, suggesting that foveal analysis and peripheral selection operated independently. These results provide important theoretical constraints on how to model target selection in conjunction with foveal object identification: in parallel and independently. PMID:24385588

  12. Changes in Regional Ventilation During Treatment and Dosimetric Advantages of CT Ventilation Image Guided Radiation Therapy for Locally Advanced Lung Cancer.

    PubMed

    Yamamoto, Tokihiro; Kabus, Sven; Bal, Matthieu; Bzdusek, Karl; Keall, Paul J; Wright, Cari; Benedict, Stanley H; Daly, Megan E

    2018-05-04

    Lung functional image guided radiation therapy (RT) that avoids irradiating highly functional regions has potential to reduce pulmonary toxicity following RT. Tumor regression during RT is common, leading to recovery of lung function. We hypothesized that computed tomography (CT) ventilation image-guided treatment planning reduces the functional lung dose compared to standard anatomic image-guided planning in 2 different scenarios with or without plan adaptation. CT scans were acquired before RT and during RT at 2 time points (16-20 Gy and 30-34 Gy) for 14 patients with locally advanced lung cancer. Ventilation images were calculated by deformable image registration of four-dimensional CT image data sets and image analysis. We created 4 treatment plans at each time point for each patient: functional adapted, anatomic adapted, functional unadapted, and anatomic unadapted plans. Adaptation was performed at 2 time points. Deformable image registration was used for accumulating dose and calculating a composite of dose-weighted ventilation used to quantify the lung accumulated dose-function metrics. The functional plans were compared with the anatomic plans for each scenario separately to investigate the hypothesis at a significance level of 0.05. Tumor volume was significantly reduced by 20% after 16 to 20 Gy (P = .02) and by 32% after 30 to 34 Gy (P < .01) on average. In both scenarios, the lung accumulated dose-function metrics were significantly lower in the functional plans than in the anatomic plans without compromising target volume coverage and adherence to constraints to critical structures. For example, functional planning significantly reduced the functional mean lung dose by 5.0% (P < .01) compared to anatomic planning in the adapted scenario and by 3.6% (P = .03) in the unadapted scenario. This study demonstrated significant reductions in the accumulated dose to the functional lung with CT ventilation image-guided planning compared to anatomic image-guided planning for patients showing tumor regression and changes in regional ventilation during RT. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Applying a food processing-based classification system to a food guide: a qualitative analysis of the Brazilian experience.

    PubMed

    Davies, Vanessa Fernandes; Moubarac, Jean-Claude; Medeiros, Kharla Janinny; Jaime, Patricia Constante

    2018-01-01

    The present paper aimed to identify the stakeholders, as well as their arguments and recommendations, in the debate on the application of a food processing-based classification system to the new Brazilian Food Guide. Qualitative approach; an analysis was made of documents resulting from the consultation conducted for the development of the new Brazilian Food Guide, which uses the NOVA classification for its dietary recommendations. A thematic matrix was constructed and the resulting themes represented the main points for discussion raised during the consultation. Brazil. Actors from academia, government and associations/unions/professional bodies/organizations related to the area of nutrition and food security; non-profit institutions linked to consumer interests and civil society organizations; organizations, associations and food unions linked to the food industry; and individuals. Four themes were identified: (i) conflicting paradigms; (ii) different perceptions about the role and need of individuals; (iii) we want more from the new food guide; and (iv) a sustainable guide. There was extensive participation from different sectors of society. The debate generated by the consultation revealed two main conflicting opinions: a view aligned with the interests of the food industry and a view of healthy eating which serves the interests of the population. The first group was against the adoption of a food processing-based classification system in a public policy such as the new Brazilian Food Guide. The second group, although mostly agreeing with the new food guide, argued that it failed to address some important issues related to the food and nutrition agenda in Brazil.

  14. The Numerical Analysis of a Turbulent Compressible Jet. Degree awarded by Ohio State Univ., 2000

    NASA Technical Reports Server (NTRS)

    DeBonis, James R.

    2001-01-01

    A numerical method to simulate high Reynolds number jet flows was formulated and applied to gain a better understanding of the flow physics. Large-eddy simulation was chosen as the most promising approach to model the turbulent structures due to its compromise between accuracy and computational expense. The filtered Navier-Stokes equations were developed including a total energy form of the energy equation. Subgrid scale models for the momentum and energy equations were adapted from compressible forms of Smagorinsky's original model. The effect of using disparate temporal and spatial accuracy in a numerical scheme was discovered through one-dimensional model problems and a new uniformly fourth-order accurate numerical method was developed. Results from two- and three-dimensional validation exercises show that the code accurately reproduces both viscous and inviscid flows. Numerous axisymmetric jet simulations were performed to investigate the effect of grid resolution, numerical scheme, exit boundary conditions and subgrid scale modeling on the solution and the results were used to guide the three-dimensional calculations. Three-dimensional calculations of a Mach 1.4 jet showed that this LES simulation accurately captures the physics of the turbulent flow. The agreement with experimental data was relatively good and is much better than results in the current literature. Turbulent intensities indicate that the turbulent structures at this level of modeling are not isotropic and this information could lend itself to the development of improved subgrid scale models for LES and turbulence models for RANS simulations. A two point correlation technique was used to quantify the turbulent structures. Two point space correlations were used to obtain a measure of the integral length scale, which proved to be approximately 1/2 D(sub j). Two point space-time correlations were used to obtain the convection velocity for the turbulent structures. This velocity ranged from 0.57 to 0.71 U(sub j).

  15. Using Runtime Analysis to Guide Model Checking of Java Programs

    NASA Technical Reports Server (NTRS)

    Havelund, Klaus; Norvig, Peter (Technical Monitor)

    2001-01-01

    This paper describes how two runtime analysis algorithms, an existing data race detection algorithm and a new deadlock detection algorithm, have been implemented to analyze Java programs. Runtime analysis is based on the idea of executing the program once. and observing the generated run to extract various kinds of information. This information can then be used to predict whether other different runs may violate some properties of interest, in addition of course to demonstrate whether the generated run itself violates such properties. These runtime analyses can be performed stand-alone to generate a set of warnings. It is furthermore demonstrated how these warnings can be used to guide a model checker, thereby reducing the search space. The described techniques have been implemented in the b e grown Java model checker called PathFinder.

  16. Laser guide star pointing camera for ESO LGS Facilities

    NASA Astrophysics Data System (ADS)

    Bonaccini Calia, D.; Centrone, M.; Pedichini, F.; Ricciardi, A.; Cerruto, A.; Ambrosino, F.

    2014-08-01

    Every observatory using LGS-AO routinely has the experience of the long time needed to bring and acquire the laser guide star in the wavefront sensor field of view. This is mostly due to the difficulty of creating LGS pointing models, because of the opto-mechanical flexures and hysteresis in the launch and receiver telescope structures. The launch telescopes are normally sitting on the mechanical structure of the larger receiver telescope. The LGS acquisition time is even longer in case of multiple LGS systems. In this framework the optimization of the LGS systems absolute pointing accuracy is relevant to boost the time efficiency of both science and technical observations. In this paper we show the rationale, the design and the feasibility tests of a LGS Pointing Camera (LPC), which has been conceived for the VLT Adaptive Optics Facility 4LGSF project. The LPC would assist in pointing the four LGS, while the VLT is doing the initial active optics cycles to adjust its own optics on a natural star target, after a preset. The LPC allows minimizing the needed accuracy for LGS pointing model calibrations, while allowing to reach sub-arcsec LGS absolute pointing accuracy. This considerably reduces the LGS acquisition time and observations operation overheads. The LPC is a smart CCD camera, fed by a 150mm diameter aperture of a Maksutov telescope, mounted on the top ring of the VLT UT4, running Linux and acting as server for the client 4LGSF. The smart camera is able to recognize within few seconds the sky field using astrometric software, determining the stars and the LGS absolute positions. Upon request it returns the offsets to give to the LGS, to position them at the required sky coordinates. As byproduct goal, once calibrated the LPC can calculate upon request for each LGS, its return flux, its fwhm and the uplink beam scattering levels.

  17. 2010 AUGUST 1-2 SYMPATHETIC ERUPTIONS. I. MAGNETIC TOPOLOGY OF THE SOURCE-SURFACE BACKGROUND FIELD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Titov, V. S.; Mikic, Z.; Toeroek, T.

    2012-11-01

    A sequence of apparently coupled eruptions was observed on 2010 August 1-2 by Solar Dynamics Observatory and STEREO. The eruptions were closely synchronized with one another, even though some of them occurred at widely separated locations. In an attempt to identify a plausible reason for such synchronization, we study the large-scale structure of the background magnetic configuration. The coronal field was computed from the photospheric magnetic field observed at the appropriate time period by using the potential field source-surface model. We investigate the resulting field structure by analyzing the so-called squashing factor calculated at the photospheric and source-surface boundaries, asmore » well as at different coronal cross-sections. Using this information as a guide, we determine the underlying structural skeleton of the configuration, including separatrix and quasi-separatrix surfaces. Our analysis reveals, in particular, several pseudo-streamers in the regions where the eruptions occurred. Of special interest to us are the magnetic null points and separators associated with the pseudo-streamers. We propose that magnetic reconnection triggered along these separators by the first eruption likely played a key role in establishing the assumed link between the sequential eruptions. The present work substantiates our recent simplified magnetohydrodynamic model of sympathetic eruptions and provides a guide for further deeper study of these phenomena. Several important implications of our results for the S-web model of the slow solar wind are also addressed.« less

  18. Application of PBPK Modeling and Virtual Clinical Study Approaches to Predict the Outcomes of CYP2D6 Genotype-Guided Dosing of Tamoxifen.

    PubMed

    Nakamura, Toshimichi; Toshimoto, Kota; Lee, Wooin; Imamura, Chiyo K; Tanigawara, Yusuke; Sugiyama, Yuichi

    2018-06-19

    The Tamoxifen Response by CYP2D6 Genotype-based Treatment-1 (TARGET-1) study (n = 180) was conducted from 2012-2017 in Japan to determine the efficacy of tamoxifen dosing guided by cytochrome P450 2D6 (CYP2D6) genotypes. To predict its outcomes prior to completion, we constructed the comprehensive physiologically based pharmacokinetic (PBPK) models of tamoxifen and its metabolites and performed virtual TARGET-1 studies. Our analyses indicated that the expected probability to achieve the end point (demonstrating the superior efficacy of the escalated tamoxifen dose over the standard dose in patients carrying CYP2D6 variants) was 0.469 on average. As the population size of this virtual clinical study (VCS) increased, the expected probability was substantially increased (0.674 for n = 260). Our analyses also informed that the probability to achieve the end point in the TARGET-1 study was negatively impacted by a large variability in endoxifen levels. Our current efforts demonstrate the promising utility of the PBPK modeling and VCS approaches in prospectively designing effective clinical trials. © 2018 The Authors CPT: Pharmacometrics & Systems Pharmacology published by Wiley Periodicals, Inc. on behalf of American Society for Clinical Pharmacology and Therapeutics.

  19. [Real-time three-dimensional (4D) ultrasound-guided prostatic biopsies on a phantom. Comparative study versus 2D guidance].

    PubMed

    Long, Jean-Alexandre; Daanen, Vincent; Moreau-Gaudry, Alexandre; Troccaz, Jocelyne; Rambeaud, Jean-Jacques; Descotes, Jean-Luc

    2007-11-01

    The objective of this study was to determine the added value of real-time three-dimensional (4D) ultrasound guidance of prostatic biopsies on a prostate phantom in terms of the precision of guidance and distribution. A prostate phantom was constructed. A real-time 3D ultrasonograph connected to a transrectal 5.9 MHz volumic transducer was used. Fourteen operators performed 336 biopsies with 2D guidance then 4D guidance according to a 12-biopsy protocol. Biopsy tracts were modelled by segmentation in a 3D ultrasound volume. Specific software allowed visualization of biopsy tracts in the reference prostate and evaluated the zone biopsied. A comparative study was performed to determine the added value of 4D guidance compared to 2D guidance by evaluating the precision of entry points and target points. The distribution was evaluated by measuring the volume investigated and by a redundancy ratio of the biopsy points. The precision of the biopsy protocol was significantly improved by 4D guidance (p = 0.037). No increase of the biopsy volume and no improvement of the distribution of biopsies were observed with 4D compared to 2D guidance. The real-time 3D ultrasound-guided prostate biopsy technique on a phantom model appears to improve the precision and reproducibility of a biopsy protocol, but the distribution of biopsies does not appear to be improved.

  20. Three-dimensional modeling of electron quasiviscous dissipation in guide-field magnetic reconnection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hesse, Michael; Kuznetsova, Masha; Schindler, Karl

    2005-10-01

    A numerical study of guide-field magnetic reconnection in a three-dimensional model is presented. Starting from an initial, perturbed, force-free current sheet, it is shown that reconnection develops to an almost translationally invariant state, where magnetic perturbations are aligned primarily along the main current flow direction. An analysis of guide-field and electron flow signatures indicates behavior that is very similar to earlier, albeit not three-dimensional, simulations. Furthermore, a detailed investigation of electron pressure nongyrotropies in the central diffusion region confirms the major role the associated dissipation process plays in establishing the reconnection electric field.

  1. Load and dynamic assessment of B-52B-008 carrier aircraft for finned configuration 1 space shuttle solid rocket booster deceleration subsystem drop test vehicle. Volume 4: Pylon load data

    NASA Technical Reports Server (NTRS)

    Quade, D. A.

    1978-01-01

    The pylon loading at the drop test vehicle and wing interface attack points is presented. The loads shown are determined using a stiffness method, which assumes the side stiffness of the forward hook guide and the fore and aft stiffness of each drag pin to be equal. The net effect of this assumption is that the forward hook guide reacts approximately 96% of the drop test vehicle yawing moment. For a comparison of these loads to previous X-15 analysis design loadings, see Volume 1 of this document.

  2. Effect of optical digitizer selection on the application accuracy of a surgical localization system-a quantitative comparison between the OPTOTRAK and flashpoint tracking systems

    NASA Technical Reports Server (NTRS)

    Li, Q.; Zamorano, L.; Jiang, Z.; Gong, J. X.; Pandya, A.; Perez, R.; Diaz, F.

    1999-01-01

    Application accuracy is a crucial factor for stereotactic surgical localization systems, in which space digitization camera systems are one of the most critical components. In this study we compared the effect of the OPTOTRAK 3020 space digitization system and the FlashPoint Model 3000 and 5000 3D digitizer systems on the application accuracy for interactive localization of intracranial lesions. A phantom was mounted with several implantable frameless markers which were randomly distributed on its surface. The target point was digitized and the coordinates were recorded and compared with reference points. The differences from the reference points represented the deviation from the "true point." The root mean square (RMS) was calculated to show the differences, and a paired t-test was used to analyze the results. The results with the phantom showed that, for 1-mm sections of CT scans, the RMS was 0.76 +/- 0. 54 mm for the OPTOTRAK system, 1.23 +/- 0.53 mm for the FlashPoint Model 3000 3D digitizer system, and 1.00 +/- 0.42 mm for the FlashPoint Model 5000 system. These preliminary results showed that there is no significant difference between the three tracking systems, and, from the quality point of view, they can all be used for image-guided surgery procedures. Copyright 1999 Wiley-Liss, Inc.

  3. Effect of optical digitizer selection on the application accuracy of a surgical localization system-a quantitative comparison between the OPTOTRAK and flashpoint tracking systems.

    PubMed

    Li, Q; Zamorano, L; Jiang, Z; Gong, J X; Pandya, A; Perez, R; Diaz, F

    1999-01-01

    Application accuracy is a crucial factor for stereotactic surgical localization systems, in which space digitization camera systems are one of the most critical components. In this study we compared the effect of the OPTOTRAK 3020 space digitization system and the FlashPoint Model 3000 and 5000 3D digitizer systems on the application accuracy for interactive localization of intracranial lesions. A phantom was mounted with several implantable frameless markers which were randomly distributed on its surface. The target point was digitized and the coordinates were recorded and compared with reference points. The differences from the reference points represented the deviation from the "true point." The root mean square (RMS) was calculated to show the differences, and a paired t-test was used to analyze the results. The results with the phantom showed that, for 1-mm sections of CT scans, the RMS was 0.76 +/- 0. 54 mm for the OPTOTRAK system, 1.23 +/- 0.53 mm for the FlashPoint Model 3000 3D digitizer system, and 1.00 +/- 0.42 mm for the FlashPoint Model 5000 system. These preliminary results showed that there is no significant difference between the three tracking systems, and, from the quality point of view, they can all be used for image-guided surgery procedures. Copyright 1999 Wiley-Liss, Inc.

  4. Dynamic Modeling of ALS Systems

    NASA Technical Reports Server (NTRS)

    Jones, Harry

    2002-01-01

    The purpose of dynamic modeling and simulation of Advanced Life Support (ALS) systems is to help design them. Static steady state systems analysis provides basic information and is necessary to guide dynamic modeling, but static analysis is not sufficient to design and compare systems. ALS systems must respond to external input variations and internal off-nominal behavior. Buffer sizing, resupply scheduling, failure response, and control system design are aspects of dynamic system design. We develop two dynamic mass flow models and use them in simulations to evaluate systems issues, optimize designs, and make system design trades. One model is of nitrogen leakage in the space station, the other is of a waste processor failure in a regenerative life support system. Most systems analyses are concerned with optimizing the cost/benefit of a system at its nominal steady-state operating point. ALS analysis must go beyond the static steady state to include dynamic system design. All life support systems exhibit behavior that varies over time. ALS systems must respond to equipment operating cycles, repair schedules, and occasional off-nominal behavior or malfunctions. Biological components, such as bioreactors, composters, and food plant growth chambers, usually have operating cycles or other complex time behavior. Buffer sizes, material stocks, and resupply rates determine dynamic system behavior and directly affect system mass and cost. Dynamic simulation is needed to avoid the extremes of costly over-design of buffers and material reserves or system failure due to insufficient buffers and lack of stored material.

  5. Evaluation of the UnTRIM model for 3-D tidal circulation

    USGS Publications Warehouse

    Cheng, R.T.; Casulli, V.; ,

    2001-01-01

    A family of numerical models, known as the TRIM models, shares the same modeling philosophy for solving the shallow water equations. A characteristic analysis of the shallow water equations points out that the numerical instability is controlled by the gravity wave terms in the momentum equations and by the transport terms in the continuity equation. A semi-implicit finite-difference scheme has been formulated so that these terms and the vertical diffusion terms are treated implicitly and the remaining terms explicitly to control the numerical stability and the computations are carried out over a uniform finite-difference computational mesh without invoking horizontal or vertical coordinate transformations. An unstructured grid version of TRIM model is introduced, or UnTRIM (pronounces as "you trim"), which preserves these basic numerical properties and modeling philosophy, only the computations are carried out over an unstructured orthogonal grid. The unstructured grid offers the flexibilities in representing complex study areas so that fine grid resolution can be placed in regions of interest, and coarse grids are used to cover the remaining domain. Thus, the computational efforts are concentrated in areas of importance, and an overall computational saving can be achieved because the total number of grid-points is dramatically reduced. To use this modeling approach, an unstructured grid mesh must be generated to properly reflect the properties of the domain of the investigation. The new modeling flexibility in grid structure is accompanied by new challenges associated with issues of grid generation. To take full advantage of this new model flexibility, the model grid generation should be guided by insights into the physics of the problems; and the insights needed may require a higher degree of modeling skill.

  6. 3D Guided Wave Motion Analysis on Laminated Composites

    NASA Technical Reports Server (NTRS)

    Tian, Zhenhua; Leckey, Cara; Yu, Lingyu

    2013-01-01

    Ultrasonic guided waves have proved useful for structural health monitoring (SHM) and nondestructive evaluation (NDE) due to their ability to propagate long distances with less energy loss compared to bulk waves and due to their sensitivity to small defects in the structure. Analysis of actively transmitted ultrasonic signals has long been used to detect and assess damage. However, there remain many challenging tasks for guided wave based SHM due to the complexity involved with propagating guided waves, especially in the case of composite materials. The multimodal nature of the ultrasonic guided waves complicates the related damage analysis. This paper presents results from parallel 3D elastodynamic finite integration technique (EFIT) simulations used to acquire 3D wave motion in the subject laminated carbon fiber reinforced polymer composites. The acquired 3D wave motion is then analyzed by frequency-wavenumber analysis to study the wave propagation and interaction in the composite laminate. The frequency-wavenumber analysis enables the study of individual modes and visualization of mode conversion. Delamination damage has been incorporated into the EFIT model to generate "damaged" data. The potential for damage detection in laminated composites is discussed in the end.

  7. REACH. Teacher's Guide Volume II. Check Points.

    ERIC Educational Resources Information Center

    Georgia Univ., Athens. Div. of Vocational Education.

    Designed for use with individualized instructional units (CE 026 345-347, CE 026 349-351) in the REACH (Refrigeration, Electro-Mechanical, Air-Conditioning, Heating) electromechanical cluster, this second volume of the postsecondary teacher guide contains the check points which the instructor may want to refer to when the unit sheet directs the…

  8. Dynamics Analysis of Anti-predator Model on Intermediate Predator With Ratio Dependent Functional Responses

    NASA Astrophysics Data System (ADS)

    Savitri, D.

    2018-01-01

    This articel discusses a predator prey model with anti-predator on intermediate predator using ratio dependent functional responses. Dynamical analysis performed on the model includes determination of equilibrium point, stability and simulation. Three kinds of equilibrium points have been discussed, namely the extinction of prey point, the extinction of intermediate predator point and the extinction of predator point are exists under certain conditions. It can be shown that the result of numerical simulations are in accordance with analitical results

  9. A Project Team Analysis Using Tuckman's Model of Small-Group Development.

    PubMed

    Natvig, Deborah; Stark, Nancy L

    2016-12-01

    Concerns about equitable workloads for nursing faculty have been well documented, yet a standardized system for workload management does not exist. A project team was challenged to establish an academic workload management system when two dissimilar universities were consolidated. Tuckman's model of small-group development was used as the framework for the analysis of processes and effectiveness of a workload project team. Agendas, notes, and meeting minutes were used as the primary sources of information. Analysis revealed the challenges the team encountered. Utilization of a team charter was an effective tool in guiding the team to become a highly productive group. Lessons learned from the analysis are discussed. Guiding a diverse group into a highly productive team is complex. The use of Tuckman's model of small-group development provided a systematic mechanism to review and understand group processes and tasks. [J Nurs Educ. 2016;55(12):675-681.]. Copyright 2016, SLACK Incorporated.

  10. Developing Character and Values for Global Citizens: Analysis of Pre-Service Science Teachers' Moral Reasoning on Socioscientific Issues

    ERIC Educational Resources Information Center

    Lee, Hyunju; Chang, Hyunsook; Choi, Kyunghee; Kim, Sung-Won; Zeidler, Dana L.

    2012-01-01

    Character and values are the essential driving forces that serve as general guides or points of reference for individuals to support decision-making and to act responsibly about global socioscientific issues (SSIs). Based on this assumption, we investigated to what extent pre-service science teachers (PSTs) of South Korea possess character and…

  11. Object Segmentation Methods for Online Model Acquisition to Guide Robotic Grasping

    NASA Astrophysics Data System (ADS)

    Ignakov, Dmitri

    A vision system is an integral component of many autonomous robots. It enables the robot to perform essential tasks such as mapping, localization, or path planning. A vision system also assists with guiding the robot's grasping and manipulation tasks. As an increased demand is placed on service robots to operate in uncontrolled environments, advanced vision systems must be created that can function effectively in visually complex and cluttered settings. This thesis presents the development of segmentation algorithms to assist in online model acquisition for guiding robotic manipulation tasks. Specifically, the focus is placed on localizing door handles to assist in robotic door opening, and on acquiring partial object models to guide robotic grasping. First, a method for localizing a door handle of unknown geometry based on a proposed 3D segmentation method is presented. Following segmentation, localization is performed by fitting a simple box model to the segmented handle. The proposed method functions without requiring assumptions about the appearance of the handle or the door, and without a geometric model of the handle. Next, an object segmentation algorithm is developed, which combines multiple appearance (intensity and texture) and geometric (depth and curvature) cues. The algorithm is able to segment objects without utilizing any a priori appearance or geometric information in visually complex and cluttered environments. The segmentation method is based on the Conditional Random Fields (CRF) framework, and the graph cuts energy minimization technique. A simple and efficient method for initializing the proposed algorithm which overcomes graph cuts' reliance on user interaction is also developed. Finally, an improved segmentation algorithm is developed which incorporates a distance metric learning (DML) step as a means of weighing various appearance and geometric segmentation cues, allowing the method to better adapt to the available data. The improved method also models the distribution of 3D points in space as a distribution of algebraic distances from an ellipsoid fitted to the object, improving the method's ability to predict which points are likely to belong to the object or the background. Experimental validation of all methods is performed. Each method is evaluated in a realistic setting, utilizing scenarios of various complexities. Experimental results have demonstrated the effectiveness of the handle localization method, and the object segmentation methods.

  12. The effect of spring pads in the secondary suspension of railway vehicles on bogie yaw resistance

    NASA Astrophysics Data System (ADS)

    Michálek, Tomáš; Zelenka, Jaromír

    2015-12-01

    This paper deals with properties of bogie yaw resistance of an electric locomotive with secondary suspension consisting of flexi-coil springs supplemented with tilting spring pads. Transversal stiffness of a sample of a spring/pad assembly was measured on a dynamic test stand of the University of Pardubice (Czech Republic) and the results were applied into a multi-body model of the locomotive created in the simulation tool 'SJKV'. On the basis of the simulation results, a detailed analysis of the bogie yaw resistance was performed in order to explain the effect in dynamic behaviour of the locomotive when the moment against bogie rotation (and therefore the distribution of guiding forces on individual wheels, as well) is influenced with the vehicle speed in a certain curve. Results of this analysis show that the application of suspension elements with strongly directionally dependent transversal stiffness into the secondary suspension can just lead to a dependency of the bogie yaw resistance on cant deficiency, i.e. on the vehicle speed in curve. This fact has wide consequences on the vehicle dynamics (especially on the guiding behaviour of the vehicle in curves) and it also points out that the current method of evaluation of the bogie yaw resistance according to relevant standards, which is related with assessment of the quasistatic safety of a railway vehicle against derailment, is not objective enough.

  13. An integrated orthognathic surgery system for virtual planning and image-guided transfer without intermediate splint.

    PubMed

    Kim, Dae-Seung; Woo, Sang-Yoon; Yang, Hoon Joo; Huh, Kyung-Hoe; Lee, Sam-Sun; Heo, Min-Suk; Choi, Soon-Chul; Hwang, Soon Jung; Yi, Won-Jin

    2014-12-01

    Accurate surgical planning and transfer of the planning in orthognathic surgery are very important in achieving a successful surgical outcome with appropriate improvement. Conventionally, the paper surgery is performed based on a 2D cephalometric radiograph, and the results are expressed using cast models and an articulator. We developed an integrated orthognathic surgery system with 3D virtual planning and image-guided transfer. The maxillary surgery of orthognathic patients was planned virtually, and the planning results were transferred to the cast model by image guidance. During virtual planning, the displacement of the reference points was confirmed by the displacement from conventional paper surgery at each procedure. The results of virtual surgery were transferred to the physical cast models directly through image guidance. The root mean square (RMS) difference between virtual surgery and conventional model surgery was 0.75 ± 0.51 mm for 12 patients. The RMS difference between virtual surgery and image-guidance results was 0.78 ± 0.52 mm, which showed no significant difference from the difference of conventional model surgery. The image-guided orthognathic surgery system integrated with virtual planning will replace physical model surgical planning and enable transfer of the virtual planning directly without the need for an intermediate splint. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Satellite Power Systems (SPS) concept definition study (Exhibit D). Volume 7: System/subsystems requirements databook

    NASA Technical Reports Server (NTRS)

    Hanley, G. M.

    1981-01-01

    This volume summarizes the basic requirements used as a guide to systems analysis, and is a basis for the selection of candidate Satellite Power Systems (SPS) point designs. Initially, these collected data reflected the level of definition resulting from the evaluation of a broad spectrum of SPS concepts. As the various concepts matured, these requirements were updated to reflect the requirements identified for the projected satellite system/subsystem point designs. Included is an updated version of earlier Rockwell concepts using klystrons as the specific microwave power amplification approach, as well as a more in-depth definition, analysis and preliminary point design on two concepts based on the use of advanced solid state technology to accomplish the task of high power amplification of the 2.45 GHz transmitted power beam to the Earth receiver. Finally, a preliminary definition of a concept using magnetrons as the microwave power amplifiers is presented.

  15. Road extraction from aerial images using a region competition algorithm.

    PubMed

    Amo, Miriam; Martínez, Fernando; Torre, Margarita

    2006-05-01

    In this paper, we present a user-guided method based on the region competition algorithm to extract roads, and therefore we also provide some clues concerning the placement of the points required by the algorithm. The initial points are analyzed in order to find out whether it is necessary to add more initial points, and this process will be based on image information. Not only is the algorithm able to obtain the road centerline, but it also recovers the road sides. An initial simple model is deformed by using region growing techniques to obtain a rough road approximation. This model will be refined by region competition. The result of this approach is that it delivers the simplest output vector information, fully recovering the road details as they are on the image, without performing any kind of symbolization. Therefore, we tried to refine a general road model by using a reliable method to detect transitions between regions. This method is proposed in order to obtain information for feeding large-scale Geographic Information System.

  16. SU-D-BRA-04: Computerized Framework for Marker-Less Localization of Anatomical Feature Points in Range Images Based On Differential Geometry Features for Image-Guided Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soufi, M; Arimura, H; Toyofuku, F

    Purpose: To propose a computerized framework for localization of anatomical feature points on the patient surface in infrared-ray based range images by using differential geometry (curvature) features. Methods: The general concept was to reconstruct the patient surface by using a mathematical modeling technique for the computation of differential geometry features that characterize the local shapes of the patient surfaces. A region of interest (ROI) was firstly extracted based on a template matching technique applied on amplitude (grayscale) images. The extracted ROI was preprocessed for reducing temporal and spatial noises by using Kalman and bilateral filters, respectively. Next, a smooth patientmore » surface was reconstructed by using a non-uniform rational basis spline (NURBS) model. Finally, differential geometry features, i.e. the shape index and curvedness features were computed for localizing the anatomical feature points. The proposed framework was trained for optimizing shape index and curvedness thresholds and tested on range images of an anthropomorphic head phantom. The range images were acquired by an infrared ray-based time-of-flight (TOF) camera. The localization accuracy was evaluated by measuring the mean of minimum Euclidean distances (MMED) between reference (ground truth) points and the feature points localized by the proposed framework. The evaluation was performed for points localized on convex regions (e.g. apex of nose) and concave regions (e.g. nasofacial sulcus). Results: The proposed framework has localized anatomical feature points on convex and concave anatomical landmarks with MMEDs of 1.91±0.50 mm and 3.70±0.92 mm, respectively. A statistically significant difference was obtained between the feature points on the convex and concave regions (P<0.001). Conclusion: Our study has shown the feasibility of differential geometry features for localization of anatomical feature points on the patient surface in range images. The proposed framework might be useful for tasks involving feature-based image registration in range-image guided radiation therapy.« less

  17. ECONOMIC GROWTH ANALYSIS SYSTEM: USER'S GUIDE VERSION 2.0

    EPA Science Inventory

    The two-volume report describes the development of and provides information needed to operate, the Economic Growth Analysis System (E-GAS) Version 2.0 model. The model will be used to project emissions inventories of volatile organic compounds (VOCs), oxides of nitrogen (NOx), a...

  18. ECONOMIC GROWTH ANALYSIS SYSTEM: USER'S GUIDE - VERSION 3.0

    EPA Science Inventory

    The two-volume report describes the development of, and provides information needed to operate, the Economic Growth Analysis System (E-GAS) Version 3.0 model. The model will be used to project emissions inventories of volatile organic compounds, oxides of nitrogen, and carbon mon...

  19. Toolbox for the Modeling and Analysis of Thermodynamic Systems (T-MATS) User's Guide

    NASA Technical Reports Server (NTRS)

    Chapman, Jeffryes W.; Lavelle, Thomas M.; May, Ryan D.; Litt, Jonathan S.; Guo, Ten-Huei

    2014-01-01

    The Toolbox for the Modeling and Analysis of Thermodynamic Systems (T-MATS) software package is an open source, MATLABSimulink toolbox (plug in) that can be used by industry professionals and academics for the development of thermodynamic and controls simulations.

  20. The Teaching Portfolio: Capturing the Scholarship in Teaching.

    ERIC Educational Resources Information Center

    Edgerton, Russell; And Others

    This report argues a case for the use of professional teaching portfolios by educators in higher education, advances a point of view about portfolio issues, and offers examples of portfolio entries. A work-sample-plus-reflection model is presented as a guide for what might be included in a portfolio and why it might be used at a particular campus.…

  1. Small Business Ownership Management Entrepreneurship. A Model for Vocational Education Program Development in Entrepreneurship.

    ERIC Educational Resources Information Center

    Arkansas Univ., Fayetteville.

    This guide for instruction in the basics of entrepreneurship is intended for use in adult education programs, and secondary and postsecondary business education programs. It can be used as integrative material for all vocational-technical programs as well, since it provides a beginning point for those who are interested in self-employment and for…

  2. Huntington II Simulation Program - RATS. Student Workbook, Teacher's Guide, and Resource Handbook.

    ERIC Educational Resources Information Center

    Frishman, Austin

    Presented are instructions for the use of "RATS," a model simulating the dynamics of a rat population in either a city or an apartment house. The student controls the conditions of growth and sets the points at which the computer program prints reports. The rat population is controlled by variables including garbage levels selected for the site,…

  3. Pin routability and pin access analysis on standard cells for layout optimization

    NASA Astrophysics Data System (ADS)

    Chen, Jian; Wang, Jun; Zhu, ChengYu; Xu, Wei; Li, Shuai; Lin, Eason; Ou, Odie; Lai, Ya-Chieh; Qu, Shengrui

    2018-03-01

    At advanced process nodes, especially at sub-28nm technology, pin accessibility and routability of standard cells has become one of the most challenging design issues due to the limited router tracks and the increased pin density. If this issue can't be found and resolved during the cell design stage, the pin access problem will be very difficult to be fixed in implementation stage and will make the low efficiency for routing. In this paper, we will introduce a holistic approach for the pin accessibility scoring and routability analysis. For accessibility, the systematic calculator which assigns score for each pin will search the available access points, consider the surrounded router layers, basic design rule and allowed via geometry. Based on the score, the "bad" pins can be found and modified. On pin routability analysis, critical pin points (placing via on this point would lead to failed via insertion) will be searched out for either layout optimization guide or set as OBS for via insertion blocking. By using this pin routability and pin access analysis flow, we are able to improve the library quality and performance.

  4. Breed differences in dogs sensitivity to human points: a meta-analysis.

    PubMed

    Dorey, Nicole R; Udell, Monique A R; Wynne, Clive D L

    2009-07-01

    The last decade has seen a substantial increase in research on the behavioral and cognitive abilities of pet dogs, Canis familiaris. The most commonly used experimental paradigm is the object-choice task in which a dog is given a choice of two containers and guided to the reinforced object by human pointing gestures. We review here studies of this type and attempt a meta-analysis of the available data. In the meta-analysis breeds of dogs were grouped into the eight categories of the American Kennel Club, and into four clusters identified by Parker and Ostrander [Parker, H.G., Ostrander, E.A., 2005. Canine genomics and genetics: running with the pack. PLoS Genet. 1, 507-513] on the basis of a genetic analysis. No differences in performance between breeds categorized in either fashion were identified. Rather, all dog breeds appear to be similarly and highly successful in following human points to locate desired food. We suggest this result could be due to the paucity of data available in published studies, and the restricted range of breeds tested.

  5. Hand–eye calibration using a target registration error model

    PubMed Central

    Morgan, Isabella; Jayarathne, Uditha; Ma, Burton; Peters, Terry M.

    2017-01-01

    Surgical cameras are prevalent in modern operating theatres and are often used as a surrogate for direct vision. Visualisation techniques (e.g. image fusion) made possible by tracking the camera require accurate hand–eye calibration between the camera and the tracking system. The authors introduce the concept of ‘guided hand–eye calibration’, where calibration measurements are facilitated by a target registration error (TRE) model. They formulate hand–eye calibration as a registration problem between homologous point–line pairs. For each measurement, the position of a monochromatic ball-tip stylus (a point) and its projection onto the image (a line) is recorded, and the TRE of the resulting calibration is predicted using a TRE model. The TRE model is then used to guide the placement of the calibration tool, so that the subsequent measurement minimises the predicted TRE. Assessing TRE after each measurement produces accurate calibration using a minimal number of measurements. As a proof of principle, they evaluated guided calibration using a webcam and an endoscopic camera. Their endoscopic camera results suggest that millimetre TRE is achievable when at least 15 measurements are acquired with the tracker sensor ∼80 cm away on the laparoscope handle for a target ∼20 cm away from the camera. PMID:29184657

  6. Francis-99: Transient CFD simulation of load changes and turbine shutdown in a model sized high-head Francis turbine

    NASA Astrophysics Data System (ADS)

    Mössinger, Peter; Jester-Zürker, Roland; Jung, Alexander

    2017-01-01

    With increasing requirements for hydropower plant operation due to intermittent renewable energy sources like wind and solar, numerical simulations of transient operations in hydraulic turbo machines become more important. As a continuation of the work performed for the first workshop which covered three steady operating conditions, in the present paper load changes and a shutdown procedure are investigated. The findings of previous studies are used to create a 360° model and compare measurements with simulation results for the operating points part load, high load and best efficiency. A mesh motion procedure is introduced, allowing to represent moving guide vanes for load changes from best efficiency to part load and high load. Additionally an automated re-mesh procedure is added for turbine shutdown to ensure reliable mesh quality during guide vane closing. All three transient operations are compared to PIV velocity measurements in the draft tube and pressure signals in the vaneless space. Simulation results of axial velocity distributions for all three steady operation points, during both load changes and for the shutdown correlated well with the measurement. An offset at vaneless space pressure is found to be a result of guide vane corrections for the simulation to ensure similar velocity fields. Short-time Fourier transformation indicating increasing amplitudes and frequencies at speed-no load conditions. Further studies will discuss the already measured start-up procedure and investigate the necessity to consider the hydraulic system dynamics upstream of the turbine by means of a 1D3D coupling between the 3D flow field and a 1D system model.

  7. A land manager's guide to point counts of birds in the Southeast

    USGS Publications Warehouse

    Hamel, P.B.; Smith, W.P.; Twedt, D.J.; Woehr, J.R.; Morris, E.; Hamilton, R.B.; Cooper, R.J.

    1996-01-01

    Current widespread concern for the status of neotropical migratory birds has sparked interest in techniques for inventorying and monitoring populations of these and other birds in southeastern forest habitats. The present guide gives detailed instructions for conducting point counts of birds. It further presents a detailed methodology for the design and conduct of inventorial and monitoring surveys based on point counts, including discussion of sample size determination, distribution of counts among habitats, cooperation among neighboring land managers, vegetation sampling, standard data format, and other topics. Appendices provide additional information, making this guide a stand-alone text for managers interested in developing inventories of bird populations on their lands.

  8. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education

    PubMed Central

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J.A.; Dandorf, Stewart J.; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-01-01

    Introduction Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. Methods This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Results Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (p<0.001) and procedural knowledge scores improved from an average score of 4 to 8 (p<0.001). Conclusion The use of this novel cadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical students to improve and maintain their technical skills. PMID:27330672

  9. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education.

    PubMed

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J A; Dandorf, Stewart J; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-05-01

    Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (p<0.001) and procedural knowledge scores improved from an average score of 4 to 8 (p<0.001). The use of this novel cadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical students to improve and maintain their technical skills.

  10. Tailored motivational message generation: A model and practical framework for real-time physical activity coaching.

    PubMed

    Op den Akker, Harm; Cabrita, Miriam; Op den Akker, Rieks; Jones, Valerie M; Hermens, Hermie J

    2015-06-01

    This paper presents a comprehensive and practical framework for automatic generation of real-time tailored messages in behavior change applications. Basic aspects of motivational messages are time, intention, content and presentation. Tailoring of messages to the individual user may involve all aspects of communication. A linear modular system is presented for generating such messages. It is explained how properties of user and context are taken into account in each of the modules of the system and how they affect the linguistic presentation of the generated messages. The model of motivational messages presented is based on an analysis of existing literature as well as the analysis of a corpus of motivational messages used in previous studies. The model extends existing 'ontology-based' approaches to message generation for real-time coaching systems found in the literature. Practical examples are given on how simple tailoring rules can be implemented throughout the various stages of the framework. Such examples can guide further research by clarifying what it means to use e.g. user targeting to tailor a message. As primary example we look at the issue of promoting daily physical activity. Future work is pointed out in applying the present model and framework, defining efficient ways of evaluating individual tailoring components, and improving effectiveness through the creation of accurate and complete user- and context models. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Robust non-rigid registration algorithm based on local affine registration

    NASA Astrophysics Data System (ADS)

    Wu, Liyang; Xiong, Lei; Du, Shaoyi; Bi, Duyan; Fang, Ting; Liu, Kun; Wu, Dongpeng

    2018-04-01

    Aiming at the problem that the traditional point set non-rigid registration algorithm has low precision and slow convergence speed for complex local deformation data, this paper proposes a robust non-rigid registration algorithm based on local affine registration. The algorithm uses a hierarchical iterative method to complete the point set non-rigid registration from coarse to fine. In each iteration, the sub data point sets and sub model point sets are divided and the shape control points of each sub point set are updated. Then we use the control point guided affine ICP algorithm to solve the local affine transformation between the corresponding sub point sets. Next, the local affine transformation obtained by the previous step is used to update the sub data point sets and their shape control point sets. When the algorithm reaches the maximum iteration layer K, the loop ends and outputs the updated sub data point sets. Experimental results demonstrate that the accuracy and convergence of our algorithm are greatly improved compared with the traditional point set non-rigid registration algorithms.

  12. A Cost-Effectiveness Analysis of Blended Versus Face-to-Face Delivery of Evidence-Based Medicine to Medical Students.

    PubMed

    Maloney, Stephen; Nicklen, Peter; Rivers, George; Foo, Jonathan; Ooi, Ying Ying; Reeves, Scott; Walsh, Kieran; Ilic, Dragan

    2015-07-21

    Blended learning describes a combination of teaching methods, often utilizing digital technologies. Research suggests that learner outcomes can be improved through some blended learning formats. However, the cost-effectiveness of delivering blended learning is unclear. This study aimed to determine the cost-effectiveness of a face-to-face learning and blended learning approach for evidence-based medicine training within a medical program. The economic evaluation was conducted as part of a randomized controlled trial (RCT) comparing the evidence-based medicine (EBM) competency of medical students who participated in two different modes of education delivery. In the traditional face-to-face method, students received ten 2-hour classes. In the blended learning approach, students received the same total face-to-face hours but with different activities and additional online and mobile learning. Online activities utilized YouTube and a library guide indexing electronic databases, guides, and books. Mobile learning involved self-directed interactions with patients in their regular clinical placements. The attribution and differentiation of costs between the interventions within the RCT was measured in conjunction with measured outcomes of effectiveness. An incremental cost-effectiveness ratio was calculated comparing the ongoing operation costs of each method with the level of EBM proficiency achieved. Present value analysis was used to calculate the break-even point considering the transition cost and the difference in ongoing operation cost. The incremental cost-effectiveness ratio indicated that it costs 24% less to educate a student to the same level of EBM competency via the blended learning approach used in the study, when excluding transition costs. The sunk cost of approximately AUD $40,000 to transition to the blended model exceeds any savings from using the approach within the first year of its implementation; however, a break-even point is achieved within its third iteration and relative savings in the subsequent years. The sensitivity analysis indicates that approaches with higher transition costs, or staffing requirements over that of a traditional method, are likely to result in negative value propositions. Under the study conditions, a blended learning approach was more cost-effective to operate and resulted in improved value for the institution after the third year iteration, when compared to the traditional face-to-face model. The wider applicability of the findings are dependent on the type of blended learning utilized, staffing expertise, and educational context.

  13. What Makes School Ethnography "Ethnographic?"

    ERIC Educational Resources Information Center

    Erickson, Frederick

    Ethnography as an inquiry process guided by a point of view rather than as a reporting process guided by a standard technique or set of techniques is the main point of this essay which suggests the application of Malinowski's theories and methods to an ethnology of the school, indicates reasons why traditional ethnography is inadequate to the…

  14. A Guide to Making Stochastic and Single Point Predictions using the Cold Exposure Survival Model (CESM)

    DTIC Science & Technology

    2008-01-01

    required soldiers to traverse knee to neck deep 14°C water. Recently, the proliferation of wilderness activities such as mountain climbing, backcountry...Red Cross Cold Water Survival Curves (Figure 2). While useful as a “ rule of thumb” estimate of hypothermia survival, models such as Molnar’s [8] are...low body fat (e.g. body builders) are an exception to this rule . The advantage of having a little more mass can be demonstrated by CESM by

  15. External heat transfer predictions in a highly loaded transonic linear turbine guide vane cascade using an upwind biased Navier-Stokes solver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gehrer, A.; Jericha, H.

    External heat transfer predictions are performed for two-dimensional turbine blade cascades. The Reynolds-averaged Navier-Stokes equations with algebraic (Arnone and Pacciani, 1998), one-equation (Spalart and Allmaras, 1994), and two-equation (low-Re {kappa}-{epsilon}, Biswas and Fukuyama, 1994) turbulence closures are solved with a fully implicit time-marching finite volume method. Comparisons with measurements (Arts et al., 1990; Arts, 1994) for a highly loaded transonic turbine nozzle guide vane cascade show good agreement in some cases, but also reveal problems with transition prediction and turbulence modeling. Special attention has been focused on the low-Re {kappa}-{epsilon} model concerning the influence of the inlet boundary condition formore » the {epsilon}-equation and problems in the stagnation point region.« less

  16. A model of the 8-25 micron point source infrared sky

    NASA Technical Reports Server (NTRS)

    Wainscoat, Richard J.; Cohen, Martin; Volk, Kevin; Walker, Helen J.; Schwartz, Deborah E.

    1992-01-01

    We present a detailed model for the IR point-source sky that comprises geometrically and physically realistic representations of the Galactic disk, bulge, stellar halo, spiral arms (including the 'local arm'), molecular ring, and the extragalactic sky. We represent each of the distinct Galactic components by up to 87 types of Galactic source, each fully characterized by scale heights, space densities, and absolute magnitudes at BVJHK, 12, and 25 microns. The model is guided by a parallel Monte Carlo simulation of the Galaxy at 12 microns. The content of our Galactic source table constitutes a good match to the 12 micron luminosity function in the simulation, as well as to the luminosity functions at V and K. We are able to produce differential and cumulative IR source counts for any bandpass lying fully within the IRAS Low-Resolution Spectrometer's range (7.7-22.7 microns as well as for the IRAS 12 and 25 micron bands. These source counts match the IRAS observations well. The model can be used to predict the character of the point source sky expected for observations from IR space experiments.

  17. CYP2C19 LOF and GOF-Guided Antiplatelet Therapy in Patients with Acute Coronary Syndrome: A Cost-Effectiveness Analysis.

    PubMed

    Jiang, Minghuan; You, Joyce H S

    2017-02-01

    This study aimed to examine the cost-effectiveness of CYP2C19 loss-of-function and gain-of-function allele guided (LOF/GOF-guided) antiplatelet therapy in patients with acute coronary syndrome (ACS) undergoing percutaneous coronary intervention (PCI). A life-long decision-analytic model was designed to simulate outcomes of three strategies: universal clopidogrel (75 mg daily), universal alternative P2Y 12 inhibitor (prasugrel 10 mg daily or ticagrelor 90 mg twice daily), and LOF/GOF-guided therapy (LOF/GOF allele carriers receiving alternative P2Y 12 inhibitor, wild-type patients receiving clopidogrel). Model outcomes included clinical event rates, quality-adjusted life-years (QALYs) gained and direct medical costs from perspective of US healthcare provider. Base-case analysis found nonfatal myocardial infarction (5.62%) and stent thrombosis (1.2%) to be the lowest in universal alternative P2Y 12 inhibitor arm, whereas nonfatal stroke (0.72%), cardiovascular death (2.42%), and major bleeding (2.73%) were lowest in LOF/GOF-guided group. LOF/GOF-guided arm gained the highest QALYs (7.5301 QALYs) at lowest life-long cost (USD 76,450). One-way sensitivity analysis showed base-case results were subject to the hazard ratio of cardiovascular death in carriers versus non-carriers of LOF allele and hazard ratio of cardiovascular death in non-carriers of LOF allele versus general patients. In probabilistic sensitivity analysis of 10,000 Monte Carlo simulations, LOF/GOF-guided therapy, universal alternative P2Y 12 inhibitor, and universal clopidogrel were the preferred strategy (willingness-to-pay threshold = 50,000 USD/QALY) in 99.07%, 0.04%, and 0.89% of time, respectively. Using both CYP2C19 GOF and LOF alleles to select antiplatelet therapy appears to be the preferred antiplatelet strategy over universal clopidogrel and universal alternative P2Y 12 inhibitor therapy for ACS patients with PCI.

  18. Dynaflow User’s Guide

    DTIC Science & Technology

    1988-11-01

    264 ANALYSIS RESTART. ............. ..... ....... 269 1.0 TITLE CARD. .............. ............. 271 2.0 CONTROL CARDS...stress soil model will provide a tool for such analysis of waterfront structures. To understand the significance of liquefaction, it is important to note...Implementing this effective stress soil model into a finite element computer program would allow analysis of soil and structure together. TECHNICAL BACKGROUND

  19. Graphical Representations and Odds Ratios in a Distance-Association Model for the Analysis of Cross-Classified Data

    ERIC Educational Resources Information Center

    de Rooij, Mark; Heiser, Willem J.

    2005-01-01

    Although RC(M)-association models have become a generally useful tool for the analysis of cross-classified data, the graphical representation resulting from such an analysis can at times be misleading. The relationships present between row category points and column category points cannot be interpreted by inter point distances but only through…

  20. AASHTO transportation asset management guide : a focus on implementation executive summary.

    DOT National Transportation Integrated Search

    2013-06-01

    This AASHTO Transportation Asset Management Executive Summary serves as a companion to the AASHTO Transportation : Asset Management GuideA Focus on Implementation, which takes as a starting point the Transportation : Asset Management Guide publish...

  1. Cognitive-behavioral intervention to promote smoking cessation for pregnant and postpartum inner city women

    PubMed Central

    Lee, Minsun; Wen, Kuang-Yi; Hui, Sui-kuen Azor; Roussi, Pagona; Hernandez, Enrique

    2015-01-01

    This study evaluated a theory-guided cognitive-behavioral counseling (CBC) intervention for smoking cessation during pregnancy and postpartum. It also explored the mediating role of cognitive-affective variables on the impact of CBC. Underserved inner city pregnant women (N = 277) were randomized to the CBC or a best practice (BP) condition, each of which consisted of two prenatal and two postpartum sessions. Assessments were obtained at baseline, late pregnancy, and 1- and 5-months postpartum. An intent-to-treat analysis found no differences between the two groups in 7-day point-prevalence abstinence. However, a respondents-only analysis revealed a significantly higher cessation rate in the CBC (37.3 %) versus the BP (19.0 %) condition at 5-months postpartum follow-up. This effect was mediated by higher quitting self-efficacy and lower cons of quitting. CBC, based on the Cognitive-Social Health Information Processing model, has the potential to increase postpartum smoking abstinence by assessing and addressing cognitive-affective barriers among women who adhere to the intervention. PMID:26335312

  2. Complexity dynamics and Hopf bifurcation analysis based on the first Lyapunov coefficient about 3D IS-LM macroeconomics system

    NASA Astrophysics Data System (ADS)

    Ma, Junhai; Ren, Wenbo; Zhan, Xueli

    2017-04-01

    Based on the study of scholars at home and abroad, this paper improves the three-dimensional IS-LM model in macroeconomics, analyzes the equilibrium point of the system and stability conditions, focuses on the parameters and complex dynamic characteristics when Hopf bifurcation occurs in the three-dimensional IS-LM macroeconomics system. In order to analyze the stability of limit cycles when Hopf bifurcation occurs, this paper further introduces the first Lyapunov coefficient to judge the limit cycles, i.e. from a practical view of the business cycle. Numerical simulation results show that within the range of most of the parameters, the limit cycle of 3D IS-LM macroeconomics is stable, that is, the business cycle is stable; with the increase of the parameters, limit cycles becomes unstable, and the value range of the parameters in this situation is small. The research results of this paper have good guide significance for the analysis of macroeconomics system.

  3. The social role of C-reactive protein point-of-care testing to guide antibiotic prescription in Northern Thailand.

    PubMed

    Haenssgen, Marco J; Charoenboon, Nutcha; Althaus, Thomas; Greer, Rachel C; Intralawan, Daranee; Lubell, Yoel

    2018-04-01

    New and affordable point-of-care testing (POCT) solutions are hoped to guide antibiotic prescription and to help limit antimicrobial resistance (AMR)-especially in low- and middle-income countries where resource constraints often prevent extensive diagnostic testing. Anthropological and sociological research has illuminated the role and impact of rapid point-of-care malaria testing. This paper expands our knowledge about the social implications of non-malarial POCT, using the case study of a C-reactive-protein point-of-care testing (CRP POCT) clinical trial with febrile patients at primary-care-level health centres in Chiang Rai province, northern Thailand. We investigate the social role of CRP POCT through its interactions with (a) the healthcare workers who use it, (b) the patients whose routine care is affected by the test, and (c) the existing patient-health system linkages that might resonate or interfere with CRP POCT. We conduct a thematic analysis of data from 58 purposively sampled pre- and post-intervention patients and healthcare workers in August 2016 and May 2017. We find widespread positive attitudes towards the test among patients and healthcare workers. Patients' views are influenced by an understanding of CRP POCT as a comprehensive blood test that provides specific diagnosis and that corresponds to notions of good care. Healthcare workers use the test to support their negotiations with patients but also to legitimise ethical decisions in an increasingly restrictive antibiotic policy environment. We hypothesise that CRP POCT could entail greater patient adherence to recommended antibiotic treatment, but it could also encourage riskier health behaviour and entail potentially adverse equity implications for patients across generations and socioeconomic strata. Our empirical findings inform the clinical literature on increasingly propagated point-of-care biomarker tests to guide antibiotic prescriptions, and we contribute to the anthropological and sociological literature through a novel conceptualisation of the patient-health system interface as an activity space into which biomarker testing is introduced. Copyright © 2018. Published by Elsevier Ltd.

  4. A method for automatic feature points extraction of human vertebrae three-dimensional model

    NASA Astrophysics Data System (ADS)

    Wu, Zhen; Wu, Junsheng

    2017-05-01

    A method for automatic extraction of the feature points of the human vertebrae three-dimensional model is presented. Firstly, the statistical model of vertebrae feature points is established based on the results of manual vertebrae feature points extraction. Then anatomical axial analysis of the vertebrae model is performed according to the physiological and morphological characteristics of the vertebrae. Using the axial information obtained from the analysis, a projection relationship between the statistical model and the vertebrae model to be extracted is established. According to the projection relationship, the statistical model is matched with the vertebrae model to get the estimated position of the feature point. Finally, by analyzing the curvature in the spherical neighborhood with the estimated position of feature points, the final position of the feature points is obtained. According to the benchmark result on multiple test models, the mean relative errors of feature point positions are less than 5.98%. At more than half of the positions, the error rate is less than 3% and the minimum mean relative error is 0.19%, which verifies the effectiveness of the method.

  5. Effects of directional uncertainty on visually-guided joystick pointing.

    PubMed

    Berryhill, Marian; Kveraga, Kestutis; Hughes, Howard C

    2005-02-01

    Reaction times generally follow the predictions of Hick's law as stimulus-response uncertainty increases, although notable exceptions include the oculomotor system. Saccadic and smooth pursuit eye movement reaction times are independent of stimulus-response uncertainty. Previous research showed that joystick pointing to targets, a motor analog of saccadic eye movements, is only modestly affected by increased stimulus-response uncertainty; however, a no-uncertainty condition (simple reaction time to 1 possible target) was not included. Here, we re-evaluate manual joystick pointing including a no-uncertainty condition. Analysis indicated simple joystick pointing reaction times were significantly faster than choice reaction times. Choice reaction times (2, 4, or 8 possible target locations) only slightly increased as the number of possible targets increased. These data suggest that, as with joystick tracking (a motor analog of smooth pursuit eye movements), joystick pointing is more closely approximated by a simple/choice step function than the log function predicted by Hick's law.

  6. Model-based cost-effectiveness analysis of B-type natriuretic peptide-guided care in patients with heart failure.

    PubMed

    Mohiuddin, Syed; Reeves, Barnaby; Pufulete, Maria; Maishman, Rachel; Dayer, Mark; Macleod, John; McDonagh, Theresa; Purdy, Sarah; Rogers, Chris; Hollingworth, William

    2016-12-28

    Monitoring B-type natriuretic peptide (BNP) to guide pharmacotherapy might improve survival in patients with heart failure with reduced ejection fraction (HFrEF) or preserved ejection fraction (HFpEF). However, the cost-effectiveness of BNP-guided care is uncertain and guidelines do not uniformly recommend it. We assessed the cost-effectiveness of BNP-guided care in patient subgroups defined by age and ejection fraction. We used a Markov model with a 3-month cycle length to estimate the lifetime health service costs, quality-adjusted life years (QALYs) and incremental net monetary benefits (iNMBs) of BNP-guided versus clinically guided care in 3 patient subgroups: (1) HFrEF patients <75 years; (2) HFpEF patients <75 years; and (3) HFrEF patients ≥75 years. There is no evidence of benefit in patients with HFpEF aged ≥75 years. We used individual patient data meta-analyses and linked primary care, hospital and mortality data to inform the key model parameters. We performed probabilistic analysis to assess the uncertainty in model results. In younger patients (<75 years) with HFrEF, the mean QALYs (5.57 vs 5.02) and costs (£63 527 vs £58 139) were higher with BNP-guided care. At the willingness-to-pay threshold of £20 000 per QALY, the positive iNMB (£5424 (95% CI £987 to £9469)) indicates that BNP-guided care is cost-effective in this subgroup. The evidence of cost-effectiveness of BNP-guided care is less strong for younger patients with HFpEF (£3155 (-£10 307 to £11 613)) and older patients (≥75 years) with HFrEF (£2267 (-£1524 to £6074)). BNP-guided care remained cost-effective in the sensitivity analyses, albeit the results were sensitive to assumptions on its sustained effect. We found strong evidence that BNP-guided care is a cost-effective alternative to clinically guided care in younger patients with HFrEF. It is potentially cost-effective in younger patients with HFpEF and older patients with HFrEF, but more evidence is required, particularly with respect to the frequency, duration and BNP target for monitoring. Cost-effectiveness results from trials in specialist settings cannot be generalised to primary care. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Computational Aerodynamic Simulations of an 840 ft/sec Tip Speed Advanced Ducted Propulsor Fan System Model for Acoustic Methods Assessment and Development

    NASA Technical Reports Server (NTRS)

    Tweedt, Daniel L.

    2014-01-01

    Computational Aerodynamic simulations of an 840 ft/sec tip speed, Advanced Ducted Propulsor fan system were performed at five different operating points on the fan operating line, in order to provide detailed internal flow field information for use with fan acoustic prediction methods presently being developed, assessed and validated. The fan system is a sub-scale, lownoise research fan/nacelle model that has undergone extensive experimental testing in the 9- by 15- foot Low Speed Wind Tunnel at the NASA Glenn Research Center, resulting in quality, detailed aerodynamic and acoustic measurement data. Details of the fan geometry, the computational fluid dynamics methods, the computational grids, and various computational parameters relevant to the numerical simulations are discussed. Flow field results for three of the five operating conditions simulated are presented in order to provide a representative look at the computed solutions. Each of the five fan aerodynamic simulations involved the entire fan system, excluding a long core duct section downstream of the core inlet guide vane. As a result, only fan rotational speed and system bypass ratio, set by specifying static pressure downstream of the core inlet guide vane row, were adjusted in order to set the fan operating point, leading to operating points that lie on a fan operating line and making mass flow rate a fully dependent parameter. The resulting mass flow rates are in good agreement with measurement values. The computed blade row flow fields for all five fan operating points are, in general, aerodynamically healthy. Rotor blade and fan exit guide vane flow characteristics are good, including incidence and deviation angles, chordwise static pressure distributions, blade surface boundary layers, secondary flow structures, and blade wakes. Examination of the computed flow fields reveals no excessive boundary layer separations or related secondary-flow problems. A few spanwise comparisons between computational and measurement data in the bypass duct show that they are in good agreement, thus providing a partial validation of the computational results.

  8. When four principles are too many: bloodgate, integrity and an action-guiding model of ethical decision making in clinical practice.

    PubMed

    Muirhead, William

    2012-04-01

    Medical ethical analysis remains dominated by the principlist account first proposed by Beauchamp and Childress. This paper argues that the principlist model is unreflective of how ethical decisions are taken in clinical practice. Two kinds of medical ethical decisions are distinguished: biosocial ethics and clinical ethics. It is argued that principlism is an inappropriate model for clinical ethics as it is neither sufficiently action-guiding nor does it emphasise the professional integrity of the clinician. An alternative model is proposed for decision making in the realm of clinical ethics.

  9. The Impending Revolution in School Business Management.

    ERIC Educational Resources Information Center

    James, H. Thomas

    The development of logically sophisticated analytical models in a growing number of fields has placed new emphasis on efficiency in school management. Recent systems models guiding the longrun analysis of school management in terms of efficiency--through cost-benefit studies, systems analysis, and program planning and budgeting systems--are in…

  10. System for the Analysis of Global Energy Markets - Vol. II, Model Documentation

    EIA Publications

    2003-01-01

    The second volume provides a data implementation guide that lists all naming conventions and model constraints. In addition, Volume 1 has two appendixes that provide a schematic of the System for the Analysis of Global Energy Markets (SAGE) structure and a listing of the source code, respectively.

  11. Subsatellite Orbital Analysis Program (SOAP) user's guide

    NASA Astrophysics Data System (ADS)

    Castle, K. G.; Voss, J. M.; Gibson, J. S.

    1981-07-01

    The features and use of the subsatellite operational analysis are examined. The model simulates several Earth-orbiting vehicles, their pilots, control systems, and interaction with the environment. The use of the program, input and output capabilities, executive structures, and properties of the vehicles and environmental effects which it models are described.

  12. Subsatellite Orbital Analysis Program (SOAP) user's guide

    NASA Technical Reports Server (NTRS)

    Castle, K. G.; Voss, J. M.; Gibson, J. S.

    1981-01-01

    The features and use of the subsatellite operational analysis are examined. The model simulates several Earth-orbiting vehicles, their pilots, control systems, and interaction with the environment. The use of the program, input and output capabilities, executive structures, and properties of the vehicles and environmental effects which it models are described.

  13. Using the Unified Modelling Language (UML) to guide the systemic description of biological processes and systems.

    PubMed

    Roux-Rouquié, Magali; Caritey, Nicolas; Gaubert, Laurent; Rosenthal-Sabroux, Camille

    2004-07-01

    One of the main issues in Systems Biology is to deal with semantic data integration. Previously, we examined the requirements for a reference conceptual model to guide semantic integration based on the systemic principles. In the present paper, we examine the usefulness of the Unified Modelling Language (UML) to describe and specify biological systems and processes. This makes unambiguous representations of biological systems, which would be suitable for translation into mathematical and computational formalisms, enabling analysis, simulation and prediction of these systems behaviours.

  14. Concepts and Preliminary Data Toward the Realization of Image-guided Liver Surgery

    PubMed Central

    Cash, David M.; Miga, Michael I.; Glasgow, Sean C.; Dawant, Benoit M.; Clements, Logan W.; Cao, Zhujiang; Galloway, Robert L.; Chapman, William C.

    2013-01-01

    Image-guided surgery provides navigational assistance to the surgeon by displaying the surgical probe position on a set of preoperative tomograms in real time. In this study, the feasibility of implementing image-guided surgery concepts into liver surgery was examined during eight hepatic resection procedures. Preoperative tomographic image data were acquired and processed. Accompanying intraoperative data on liver shape and position were obtained through optically tracked probes and laser range scanning technology. The preoperative and intraoperative representations of the liver surface were aligned using the iterative closest point surface matching algorithm. Surface registrations resulted in mean residual errors from 2 to 6 mm, with errors of target surface regions being below a stated goal of 1 cm. Issues affecting registration accuracy include liver motion due to respiration, the quality of the intraoperative surface data, and intraoperative organ deformation. Respiratory motion was quantified during the procedures as cyclical, primarily along the cranial–caudal direction. The resulting registrations were more robust and accurate when using laser range scanning to rapidly acquire thousands of points on the liver surface and when capturing unique geometric regions on the liver surface, such as the inferior edge. Finally, finite element models recovered much of the observed intraoperative deformation, further decreasing errors in the registration. Image-guided liver surgery has shown the potential to provide surgeons with important navigation aids that could increase the accuracy of targeting lesions and the number of patients eligible for surgical resection. PMID:17458587

  15. Manned systems utilization analysis (study 2.1). Volume 4: Program manual and users guide for the LOVES computer code

    NASA Technical Reports Server (NTRS)

    Wray, S. T., Jr.

    1975-01-01

    Information necessary to use the LOVES computer program in its existing state or to modify the program to include studies not properly handled by the basic model is provided. A users guide, a programmers manual, and several supporting appendices are included.

  16. Pilot/vehicle model analysis of visually guided flight

    NASA Technical Reports Server (NTRS)

    Zacharias, Greg L.

    1991-01-01

    Information is given in graphical and outline form on a pilot/vehicle model description, control of altitude with simple terrain clues, simulated flight with visual scene delays, model-based in-cockpit display design, and some thoughts on the role of pilot/vehicle modeling.

  17. Steerability Analysis of Tracked Vehicles: Theory and User’s Guide for Computer Program TVSTEER

    DTIC Science & Technology

    1986-08-01

    Baladi , Donald E. Barnes, Rebecca P. BergerC oStructures Laboratory NDEPARTMENT OF THE ARMY ___ Waterways Experiment Station, Corps of Engineers . U P0 Box...Analysis of Tracked Vehicles: Theory and User’s Guide for Computer Program TVSTEER - 12 PERSONAL AUTHOR(S) Baladi , George Y., Barnes, Donald E...mathematical model was formulated by Drs. George Y. Baladi and Behzad Rohani. The logic and computer programming were accomplished by Dr. Baladi and

  18. Load and dynamic assessment of B-52B-008 carrier aircraft for finned configuration 1 space shuttle solid rocket booster decelerator subsystem drop test vehicle. Volume 3: Pylon load data method 1

    NASA Technical Reports Server (NTRS)

    Quade, D. A.

    1978-01-01

    The pylon loading at the drop test vehicle and wing interface attach points is presented. The loads shown are determined using a stiffness method, which assumes the side stiffness of the foreward hook guide to be one-fourth of the fore and aft stiffness of each drag pin. The net effect of this assumption is that the forward hook guide reacts approximately 85% of the drop test vehicle yawing moment. For a comparison of these loads to previous X-15 analysis design loadings, see Volume 1 of this document.

  19. Objective assessment of operator performance during ultrasound-guided procedures.

    PubMed

    Tabriz, David M; Street, Mandie; Pilgram, Thomas K; Duncan, James R

    2011-09-01

    Simulation permits objective assessment of operator performance in a controlled and safe environment. Image-guided procedures often require accurate needle placement, and we designed a system to monitor how ultrasound guidance is used to monitor needle advancement toward a target. The results were correlated with other estimates of operator skill. The simulator consisted of a tissue phantom, ultrasound unit, and electromagnetic tracking system. Operators were asked to guide a needle toward a visible point target. Performance was video-recorded and synchronized with the electromagnetic tracking data. A series of algorithms based on motor control theory and human information processing were used to convert raw tracking data into different performance indices. Scoring algorithms converted the tracking data into efficiency, quality, task difficulty, and targeting scores that were aggregated to create performance indices. After initial feasibility testing, a standardized assessment was developed. Operators (N = 12) with a broad spectrum of skill and experience were enrolled and tested. Overall scores were based on performance during ten simulated procedures. Prior clinical experience was used to independently estimate operator skill. When summed, the performance indices correlated well with estimated skill. Operators with minimal or no prior experience scored markedly lower than experienced operators. The overall score tended to increase according to operator's clinical experience. Operator experience was linked to decreased variation in multiple aspects of performance. The aggregated results of multiple trials provided the best correlation between estimated skill and performance. A metric for the operator's ability to maintain the needle aimed at the target discriminated between operators with different levels of experience. This study used a highly focused task model, standardized assessment, and objective data analysis to assess performance during simulated ultrasound-guided needle placement. The performance indices were closely related to operator experience.

  20. In-line inspection of unpiggable buried live gas pipes using circumferential EMAT guided waves

    NASA Astrophysics Data System (ADS)

    Ren, Baiyang; Xin, Junjun

    2018-04-01

    Unpiggable buried gas pipes need to be inspected to ensure their structural integrity and safe operation. The CIRRIS XITM robot, developed and operated by ULC Robotics, conducts in-line nondestructive inspection of live gas pipes. With the no-blow launching system, the inspection operation has reduced disruption to the public and by eliminating the need to dig trenches, has minimized the site footprint. This provides a highly time and cost effective solution for gas pipe maintenance. However, the current sensor on the robot performs a point-by-point measurement of the pipe wall thickness which cannot cover the whole volume of the pipe in a reasonable timeframe. The study of ultrasonic guided wave technique is discussed to improve the volume coverage as well as the scanning speed. Circumferential guided wave is employed to perform axial scanning. Mode selection is discussed in terms of sensitivity to different defects and defect characterization capability. To assist with the mode selection, finite element analysis is performed to evaluate the wave-defect interaction and to identify potential defect features. Pulse-echo and through-transmission mode are evaluated and compared for their pros and cons in axial scanning. Experiments are also conducted to verify the mode selection and detect and characterize artificial defects introduced into pipe samples.

  1. Improving the Impact of Extension through the Use of Anticipation Guides

    ERIC Educational Resources Information Center

    Smith, Rebecca C.; Lemley, Stephanie M.

    2017-01-01

    In this article, we present the anticipation guide as a tool for preparing Extension audiences to learn the main points of Extension materials. Anticipation guides improve learner comprehension by appealing to an individual's natural curiosity and helping the individual focus on key ideas. Anticipation guides can be used with all types of…

  2. A Land Manager's Guide to Point Counts of Birds in the Southeast

    Treesearch

    Paul B. Hamel; Winston P. Smith; Daniel J. Twedt; James R. Woehr; Eddie Morris; Robert B. Hamilton; Robert J. Cooper

    1996-01-01

    Current widespread concern for the status of neotropical migratory birds has sparked interest in techniques for inventorying and monitoring populations of these and other birds in southeastern forest habitats. The present guide gives detailed instructions for conducting point counts of birds. It further presents a detailed methodology for the design and conduct of...

  3. Micromechanics of metal matrix composites using the Generalized Method of Cells model (GMC) user's guide

    NASA Technical Reports Server (NTRS)

    Aboudi, Jacob; Pindera, Marek-Jerzy

    1992-01-01

    A user's guide for the program gmc.f is presented. The program is based on the generalized method of cells model (GMC) which is capable via a micromechanical analysis, of predicting the overall, inelastic behavior of unidirectional, multi-phase composites from the knowledge of the properties of the viscoplastic constituents. In particular, the program is sufficiently general to predict the response of unidirectional composites having variable fiber shapes and arrays.

  4. HyRAM V1.0 User Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Groth, Katrina M.; Zumwalt, Hannah Ruth; Clark, Andrew Jordan

    2016-03-01

    Hydrogen Risk Assessment Models (HyRAM) is a prototype software toolkit that integrates data and methods relevant to assessing the safety of hydrogen fueling and storage infrastructure. The HyRAM toolkit integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, and characterizing the impact of hydrogen hazards, including thermal effects from jet fires and thermal pressure effects from deflagration. HyRAM version 1.0 incorporates generic probabilities for equipment failures for nine types of components, and probabilistic models for the impact of heat flux on humans and structures, with computationally and experimentally validated models of various aspects of gaseous hydrogen releasemore » and flame physics. This document provides an example of how to use HyRAM to conduct analysis of a fueling facility. This document will guide users through the software and how to enter and edit certain inputs that are specific to the user-defined facility. Description of the methodology and models contained in HyRAM is provided in [1]. This User’s Guide is intended to capture the main features of HyRAM version 1.0 (any HyRAM version numbered as 1.0.X.XXX). This user guide was created with HyRAM 1.0.1.798. Due to ongoing software development activities, newer versions of HyRAM may have differences from this guide.« less

  5. Visualization of Flows in Packed Beds of Twisted Tapes

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Braun, M. J.; Peloso, D.; Athavale, M. M.; Mullen, R. L.

    2002-01-01

    A videotape presentation of the flow field in a packed bed of 48 twisted tapes which can be simulated by very thin virtual cylinders has been assembled. The indices of refraction of the oil and the Lucite twisted tapes were closely matched, and the flow was seeded with magnesium oxide particles. Planar laser light projected the flow field in two dimensions both along and transverse to the flow axis. The flow field was three dimensional and complex to describe, yet the most prominent finding was flow threads. It appeared that axial flow spiraled along either within the confines of a virtual cylindrical boundary or within the exterior region, between the tangency points, of the virtual cylinders. Random packing and bed voids created vortices and disrupted the laminar flow but minimized the entrance effects. The flow-pressure drops in the packed bed fell below the Ergun model for porous-media flows. Single-twisted-tape results of Smithberg and Landis (1964) were used to guide the analysis. In appendix A the results of several investigators are scaled to the Ergun model. Further investigations including different geometric configurations, computational fluid dynamic (CFD) gridding, and analysis are required.

  6. Constructing Models in Teaching of Chemical Bonds: Ionic Bond, Covalent Bond, Double and Triple Bonds, Hydrogen Bond and Molecular Geometry

    ERIC Educational Resources Information Center

    Uce, Musa

    2015-01-01

    Studies in chemistry education show that chemistry topics are considered as abstract, complicated and hard to understand by students. For this reason, it is important to develop new materials and use them in classes for better understanding of abstract concepts. Moving from this point, a student-centered research guided by a teacher was conducted…

  7. A conceptual guide to detection probability for point counts and other count-based survey methods

    Treesearch

    D. Archibald McCallum

    2005-01-01

    Accurate and precise estimates of numbers of animals are vitally needed both to assess population status and to evaluate management decisions. Various methods exist for counting birds, but most of those used with territorial landbirds yield only indices, not true estimates of population size. The need for valid density estimates has spawned a number of models for...

  8. Guided discovery of the nine-point circle theorem and its proof

    NASA Astrophysics Data System (ADS)

    Buchbinder, Orly

    2018-01-01

    The nine-point circle theorem is one of the most beautiful and surprising theorems in Euclidean geometry. It establishes an existence of a circle passing through nine points, all of which are related to a single triangle. This paper describes a set of instructional activities that can help students discover the nine-point circle theorem through investigation in a dynamic geometry environment, and consequently prove it using a method of guided discovery. The paper concludes with a variety of suggestions for the ways in which the whole set of activities can be implemented in geometry classrooms.

  9. Business Modeling to Implement an eHealth Portal for Infection Control: A Reflection on Co-Creation With Stakeholders.

    PubMed

    van Limburg, Maarten; Wentzel, Jobke; Sanderman, Robbert; van Gemert-Pijnen, Lisette

    2015-08-13

    It is acknowledged that the success and uptake of eHealth improve with the involvement of users and stakeholders to make technology reflect their needs. Involving stakeholders in implementation research is thus a crucial element in developing eHealth technology. Business modeling is an approach to guide implementation research for eHealth. Stakeholders are involved in business modeling by identifying relevant stakeholders, conducting value co-creation dialogs, and co-creating a business model. Because implementation activities are often underestimated as a crucial step while developing eHealth, comprehensive and applicable approaches geared toward business modeling in eHealth are scarce. This paper demonstrates the potential of several stakeholder-oriented analysis methods and their practical application was demonstrated using Infectionmanager as an example case. In this paper, we aim to demonstrate how business modeling, with the focus on stakeholder involvement, is used to co-create an eHealth implementation. We divided business modeling in 4 main research steps. As part of stakeholder identification, we performed literature scans, expert recommendations, and snowball sampling (Step 1). For stakeholder analyzes, we performed "basic stakeholder analysis," stakeholder salience, and ranking/analytic hierarchy process (Step 2). For value co-creation dialogs, we performed a process analysis and stakeholder interviews based on the business model canvas (Step 3). Finally, for business model generation, we combined all findings into the business model canvas (Step 4). Based on the applied methods, we synthesized a step-by-step guide for business modeling with stakeholder-oriented analysis methods that we consider suitable for implementing eHealth. The step-by-step guide for business modeling with stakeholder involvement enables eHealth researchers to apply a systematic and multidisciplinary, co-creative approach for implementing eHealth. Business modeling becomes an active part in the entire development process of eHealth and starts an early focus on implementation, in which stakeholders help to co-create the basis necessary for a satisfying success and uptake of the eHealth technology.

  10. Spatially distributed model calibration of flood inundation guided by consequences such as loss of property

    NASA Astrophysics Data System (ADS)

    Pappenberger, F.; Beven, K. J.; Frodsham, K.; Matgen, P.

    2005-12-01

    Flood inundation models play an increasingly important role in assessing flood risk. The growth of 2D inundation models that are intimately related to raster maps of floodplains is occurring at the same time as an increase in the availability of 2D remote data (e.g. SAR images and aerial photographs), against which model performancee can be evaluated. This requires new techniques to be explored in order to evaluate model performance in two dimensional space. In this paper we present a fuzzified pattern matching algorithm which compares favorably to a set of traditional measures. However, we further argue that model calibration has to go beyond the comparison of physical properties and should demonstrate how a weighting towards consequences, such as loss of property, can enhance model focus and prediction. Indeed, it will be necessary to abandon a fully spatial comparison in many scenarios to concentrate the model calibration exercise on specific points such as hospitals, police stations or emergency response centers. It can be shown that such point evaluations lead to significantly different flood hazard maps due to the averaging effect of a spatial performance measure. A strategy to balance the different needs (accuracy at certain spatial points and acceptable spatial performance) has to be based in a public and political decision making process.

  11. A unifying framework for systems modeling, control systems design, and system operation

    NASA Technical Reports Server (NTRS)

    Dvorak, Daniel L.; Indictor, Mark B.; Ingham, Michel D.; Rasmussen, Robert D.; Stringfellow, Margaret V.

    2005-01-01

    Current engineering practice in the analysis and design of large-scale multi-disciplinary control systems is typified by some form of decomposition- whether functional or physical or discipline-based-that enables multiple teams to work in parallel and in relative isolation. Too often, the resulting system after integration is an awkward marriage of different control and data mechanisms with poor end-to-end accountability. System of systems engineering, which faces this problem on a large scale, cries out for a unifying framework to guide analysis, design, and operation. This paper describes such a framework based on a state-, model-, and goal-based architecture for semi-autonomous control systems that guides analysis and modeling, shapes control system software design, and directly specifies operational intent. This paper illustrates the key concepts in the context of a large-scale, concurrent, globally distributed system of systems: NASA's proposed Array-based Deep Space Network.

  12. How to use multi-criteria decision analysis methods for reimbursement decision-making in healthcare: a step-by-step guide.

    PubMed

    Diaby, Vakaramoko; Goeree, Ron

    2014-02-01

    In recent years, the quest for more comprehensiveness, structure and transparency in reimbursement decision-making in healthcare has prompted the research into alternative decision-making frameworks. In this environment, multi-criteria decision analysis (MCDA) is arising as a valuable tool to support healthcare decision-making. In this paper, we present the main MCDA decision support methods (elementary methods, value-based measurement models, goal programming models and outranking models) using a case study approach. For each family of methods, an example of how an MCDA model would operate in a real decision-making context is presented from a critical perspective, highlighting the parameters setting, the selection of the appropriate evaluation model as well as the role of sensitivity and robustness analyses. This study aims to provide a step-by-step guide on how to use MCDA methods for reimbursement decision-making in healthcare.

  13. A framework for correcting brain retraction based on an eXtended Finite Element Method using a laser range scanner.

    PubMed

    Li, Ping; Wang, Weiwei; Song, Zhijian; An, Yong; Zhang, Chenxi

    2014-07-01

    Brain retraction causes great distortion that limits the accuracy of an image-guided neurosurgery system that uses preoperative images. Therefore, brain retraction correction is an important intraoperative clinical application. We used a linear elastic biomechanical model, which deforms based on the eXtended Finite Element Method (XFEM) within a framework for brain retraction correction. In particular, a laser range scanner was introduced to obtain a surface point cloud of the exposed surgical field including retractors inserted into the brain. A brain retraction surface tracking algorithm converted these point clouds into boundary conditions applied to XFEM modeling that drive brain deformation. To test the framework, we performed a brain phantom experiment involving the retraction of tissue. Pairs of the modified Hausdorff distance between Canny edges extracted from model-updated images, pre-retraction, and post-retraction CT images were compared to evaluate the morphological alignment of our framework. Furthermore, the measured displacements of beads embedded in the brain phantom and the predicted ones were compared to evaluate numerical performance. The modified Hausdorff distance of 19 pairs of images decreased from 1.10 to 0.76 mm. The forecast error of 23 stainless steel beads in the phantom was between 0 and 1.73 mm (mean 1.19 mm). The correction accuracy varied between 52.8 and 100 % (mean 81.4 %). The results demonstrate that the brain retraction compensation can be incorporated intraoperatively into the model-updating process in image-guided neurosurgery systems.

  14. Instability analysis of a model pump-turbine in vaneless space with different openings of guide vanes

    NASA Astrophysics Data System (ADS)

    Liu, J.; Liu, S.; Zuo, Z.; Wu, Y.

    2014-03-01

    Pump-turbines were always running at partial condition with the power grid changing. Flow separations and stall phenomena were obvious in the pump-turbine. Most of the RANS turbulence models solved the shear stress by linear difference scheme and they were isotropous, so they couldn't capture all kinds of vortexes in the pump-turbine well. At present, Partially-Averaged Navier-Stokes (PANS) has been found better than LES in simulating flow regions especially those with poor near-wall resolution. In this paper, a new nonlinear PANS turbulence model was proposed, which was modified from RNG k-ε turbulence model and the shear stresses were solved by Ehrhard's nonlinear methods. The nonlinear PANS model was used to study the instability of "S" region of a model pump-turbine with misaligned guide vanes (MGV). The opening of pre-opened guide vanes had great influence on the "S" characteristics. Pressure fluctuations in the vaneless space for different opening of pre-opened guide vanes were analyzed. It is found that the "S" characteristics and instability can be improved when the relative pre-opening of MGV is 50%.

  15. Integration of Microfractionation, qNMR and Zebrafish Screening for the In Vivo Bioassay-Guided Isolation and Quantitative Bioactivity Analysis of Natural Products

    PubMed Central

    Maes, Jan; Siverio-Mota, Dany; Marcourt, Laurence; Munck, Sebastian; Kamuhabwa, Appolinary R.; Moshi, Mainen J.; Esguerra, Camila V.; de Witte, Peter A. M.; Crawford, Alexander D.; Wolfender, Jean-Luc

    2013-01-01

    Natural products (NPs) are an attractive source of chemical diversity for small-molecule drug discovery. Several challenges nevertheless persist with respect to NP discovery, including the time and effort required for bioassay-guided isolation of bioactive NPs, and the limited biomedical relevance to date of in vitro bioassays used in this context. With regard to bioassays, zebrafish have recently emerged as an effective model system for chemical biology, allowing in vivo high-content screens that are compatible with microgram amounts of compound. For the deconvolution of the complex extracts into their individual constituents, recent progress has been achieved on several fronts as analytical techniques now enable the rapid microfractionation of extracts, and microflow NMR methods have developed to the point of allowing the identification of microgram amounts of NPs. Here we combine advanced analytical methods with high-content screening in zebrafish to create an integrated platform for microgram-scale, in vivo NP discovery. We use this platform for the bioassay-guided fractionation of an East African medicinal plant, Rhynchosia viscosa, resulting in the identification of both known and novel isoflavone derivatives with anti-angiogenic and anti-inflammatory activity. Quantitative microflow NMR is used both to determine the structure of bioactive compounds and to quantify them for direct dose-response experiments at the microgram scale. The key advantages of this approach are (1) the microgram scale at which both biological and analytical experiments can be performed, (2) the speed and the rationality of the bioassay-guided fractionation – generic for NP extracts of diverse origin – that requires only limited sample-specific optimization and (3) the use of microflow NMR for quantification, enabling the identification and dose-response experiments with only tens of micrograms of each compound. This study demonstrates that a complete in vivo bioassay-guided fractionation can be performed with only 20 mg of NP extract within a few days. PMID:23700445

  16. Point-of-Care Ultrasonography Findings and Care Use Among Patients Undergoing Ultrasound-Guided Shoulder Injections.

    PubMed

    Lee, Se Won; Tiu, Timothy; Roberts, Jeremy; Lee, Brian; Bartels, Matthew N; Oh-Park, Mooyeon

    2018-01-01

    The aims of the study were to assess the overall reduction of pain in patients undergoing ultrasound-guided shoulder injections and to characterize the preinjection point-of-care ultrasound findings and use of clinical services postinjection including the use of magnetic resonance imaging and surgeries. Data of 172 patients who underwent ultrasound-guided subacromial subdeltoid injection or glenohumeral joint injection were reviewed for preinjection point-of-care ultrasound findings, change in pain intensity at 2 mos from baseline, and use of care at 6 mos' postinjection. Pain intensity was measured by the numeric rating scale and a dichotomous report of global impression of significant improvement in pain. Responders were defined as those with 50% or more reduction in numeric rating scale or those with global impression of 50% or more improvement. There were 141 responders among the 172 patients analyzed. Full-thickness rotator cuff tears were higher in the ultrasound-guided subacromial subdeltoid injection group when compared with the glenohumeral joint injection group (P = 0.038) and abnormal bicipital tendon findings higher in the glenohumeral joint injection group (P = 0.016). There were no significant differences in specific abnormal U findings between responders versus nonresponders. Twelve patients had a shoulder magnetic resonance imaging and four patients underwent operative interventions after the injection. Overall pain reduction after ultrasound-guided shoulder injections was favorable in the short term. There was no specific preinjection point-of-care ultrasound findings associated with clinical pain reduction after injection. Additional imaging and operative intervention after ultrasound-guided shoulder injections seemed to be relatively low.

  17. A novel method of C1-C2 transarticular screw insertion for symptomatic atlantoaxial instability using a customized guiding block: A case report and a technical note.

    PubMed

    Huang, Kuo-Yuan; Lin, Ruey-Mo; Fang, Jing-Jing

    2016-10-01

    Atlantoaxial instability treated with the C1-2 transarticular screw fixation is biomechanically more stable; however, the technique demanding and the potential risk of neurovascular injury create difficulties for clinical usage, and there is still lack of clinical experience till now.We reported an adult female patient with symptomatic atlantoaxial instability due to rheumatoid arthritis that was successfully treated with a bilateral C1-C2 transarticular screw fixation using a customized guiding block. We preoperatively determined the trajectories for bilateral C1-C2 transarticular screws on a 3-dimensional reconstruction model from the computed tomography (CT) and self-developed computer software, and designed a rapid prototyping customized guiding block in order to offer a guide for the entry point and insertion angle of the C1-C2 transarticular screws.The clinical outcome was good, and the follow-up period was >3 years. The accuracy of the screws is good in comparison with preoperative and postoperative CT findings, and no neurovascular injury occurred.The patient was accurately and successfully treated with a bilateral C1-C2 transarticular screw fixation using a customized guiding block.

  18. Advanced earth observation spacecraft computer-aided design software: Technical, user and programmer guide

    NASA Technical Reports Server (NTRS)

    Farrell, C. E.; Krauze, L. D.

    1983-01-01

    The IDEAS computer of NASA is a tool for interactive preliminary design and analysis of LSS (Large Space System). Nine analysis modules were either modified or created. These modules include the capabilities of automatic model generation, model mass properties calculation, model area calculation, nonkinematic deployment modeling, rigid-body controls analysis, RF performance prediction, subsystem properties definition, and EOS science sensor selection. For each module, a section is provided that contains technical information, user instructions, and programmer documentation.

  19. Model-guided control of hippocampal discharges by local direct current stimulation.

    PubMed

    Mina, Faten; Modolo, Julien; Recher, Fanny; Dieuset, Gabriel; Biraben, Arnaud; Benquet, Pascal; Wendling, Fabrice

    2017-05-10

    Neurostimulation is an emerging treatment for drug-resistant epilepsies when surgery is contraindicated. Recent clinical results demonstrate significant seizure frequency reduction in epileptic patients, however the mechanisms underlying this therapeutic effect are largely unknown. This study aimed at gaining insights into local direct current stimulation (LDCS) effects on hyperexcitable tissue, by i) analyzing the impact of electrical currents locally applied on epileptogenic brain regions, and ii) characterizing currents achieving an "anti-epileptic" effect (excitability reduction). First, a neural mass model of hippocampal circuits was extended to accurately reproduce the features of hippocampal paroxysmal discharges (HPD) observed in a mouse model of epilepsy. Second, model predictions regarding current intensity and stimulation polarity were confronted to in vivo mice recordings during LDCS (n = 8). The neural mass model was able to generate realistic hippocampal discharges. Simulation of LDCS in the model pointed at a significant decrease of simulated HPD (in duration and occurrence rate, not in amplitude) for cathodal stimulation, which was successfully verified experimentally in epileptic mice. Despite the simplicity of our stimulation protocol, these results contribute to a better understanding of clinical benefits observed in epileptic patients with implanted neurostimulators. Our results also provide further support for model-guided design of neuromodulation therapy.

  20. 3D-Printed Patient-Specific ACL Femoral Tunnel Guide from MRI.

    PubMed

    Rankin, Iain; Rehman, Haroon; Frame, Mark

    2018-01-01

    Traditional ACL reconstruction with non-anatomic techniques can demonstrate unsatisfactory long-term outcomes with regards instability and the degenerative knee changes observed with these results. Anatomic ACL reconstruction attempts to closely reproduce the patient's individual anatomic characteristics with the aim of restoring knee kinematics, in order to improve patient short and long-term outcomes. We designed an arthroscopic, patient-specific, ACL femoral tunnel guide to aid anatomical placement of the ACL graft within the femoral tunnel. The guide design was based on MRI scan of the subject's uninjured contralateral knee, identifying the femoral footprint and its anatomical position relative to the borders of the femoral articular cartilage. Image processing software was used to create a 3D computer aided design which was subsequently exported to a 3D-printing service. Transparent acrylic based photopolymer, PA220 plastic and 316L stainless steel patient-specific ACL femoral tunnel guides were created; the models produced were accurate with no statistical difference in size and positioning of the center of the ACL femoral footprint guide to MRI ( p =0.344, p =0.189, p =0.233 respectively). The guides aim to provide accurate marking of the starting point of the femoral tunnel in arthroscopic ACL reconstruction. This study serves as a proof of concept for the accurate creation of 3D-printed patient-specific guides for the anatomical placement of the femoral tunnel during ACL reconstruction.

  1. Forensic Schedule Analysis of Construction Delay in Military Projects in the Middle East

    DTIC Science & Technology

    This research performs forensic schedule analysis of delay factors that impacted recent large-scale military construction projects in the Middle East...The methodologies for analysis are adapted from the Professional Practice Guide to Forensic Schedule Analysis, particularly Method 3.7 Modeled

  2. Effect of Secondary Jet-flow Angle on Performance of Turbine Inter-guide-vane Burner Based on Jet-vortex Flow

    NASA Astrophysics Data System (ADS)

    Zheng, Haifei; Tang, Hao; Xu, Xingya; Li, Ming

    2014-08-01

    Four different secondary airflow angles for the turbine inter-guide-vane burners with trapped vortex cavity were designed. Comparative analysis between combustion performances influenced by the variation of secondary airflow angle was carried out by using numerical simulation method. The turbulence was modeled using the Scale-Adaptive Simulation (SAS) turbulence model. Four cases with different secondary jet-flow angles (-45°, 0°, 30°, 60°) were studied. It was observed that the case with secondary jet-flows at 60° angle directed upwards (1) has good mixing effect; (2) mixing effect is the best although the flow field distributions inside both of the cavity and the main flow passage for the four models are very similar; (3) has complete combustion and symmetric temperature distribution on the exit section of guide vane (X = 70 mm), with uniform temperature distribution, less temperature gradient, and shrank local high temperature regions in the notch located on the guide vane.

  3. Investigation of the reconstruction accuracy of guided wave tomography using full waveform inversion

    NASA Astrophysics Data System (ADS)

    Rao, Jing; Ratassepp, Madis; Fan, Zheng

    2017-07-01

    Guided wave tomography is a promising tool to accurately determine the remaining wall thicknesses of corrosion damages, which are among the major concerns for many industries. Full Waveform Inversion (FWI) algorithm is an attractive guided wave tomography method, which uses a numerical forward model to predict the waveform of guided waves when propagating through corrosion defects, and an inverse model to reconstruct the thickness map from the ultrasonic signals captured by transducers around the defect. This paper discusses the reconstruction accuracy of the FWI algorithm on plate-like structures by using simulations as well as experiments. It was shown that this algorithm can obtain a resolution of around 0.7 wavelengths for defects with smooth depth variations from the acoustic modeling data, and about 1.5-2 wavelengths from the elastic modeling data. Further analysis showed that the reconstruction accuracy is also dependent on the shape of the defect. It was demonstrated that the algorithm maintains the accuracy in the case of multiple defects compared to conventional algorithms based on Born approximation.

  4. Acquiring, recording, and analyzing pathology data from experimental mice: an overview.

    PubMed

    Scudamore, Cheryl L

    2014-03-21

    Pathology is often underutilized as an end point in mouse studies in academic research because of a lack of experience and expertise. The use of traditional pathology techniques including necropsy and microscopic analysis can be useful in identifying the basic processes underlying a phenotype and facilitating comparison with equivalent human diseases. This overview aims to provide a guide and reference to the acquisition, recording, and analysis of high-quality pathology data from experimental mice in an academic research setting. Copyright © 2014 John Wiley & Sons, Inc.

  5. Isohaline position as a habitat indicator for estuarine populations

    USGS Publications Warehouse

    Jassby, Alan D.; Kimmerer, W.J.; Monismith, Stephen G.; Armor, C.; Cloern, James E.; Powell, T.M.; Vedlinski, Timothy J.

    1995-01-01

    The striped bass survival data were also used to illustrate a related important point: incorporating additionalexplanatory variables may decrease the prediction error for a population or process, but it can increase theuncertainty in parameter estimates and management strategies based on these estimates. Even in cases wherethe uncertainty is currently too large to guide management decisions, an uncertainty analysis can identify themost practical direction for future data acquisition.

  6. The effect of a guide field on local energy conversion during asymmetric magnetic reconnection: Particle-in-cell simulations

    NASA Astrophysics Data System (ADS)

    Cassak, P.; Genestreti, K.; Burch, J. L.; Shay, M.; Swisdak, M.; Drake, J. F.; Price, L.; Eriksson, S.; Anderson, B. J.; Merkin, V. G.; Komar, C. M.; Phan, T.; Ergun, R.

    2017-12-01

    We use theoretical and computational techniques to study how the out-of-plane (guide) magnetic field strength modifies the location where the energy conversion rate between the electric field and the plasma is appreciable during asymmetric magnetic reconnection, motivated by observations by Genestreti et al. (J. Geophys. Res, submitted). For weak guide fields, the energy conversion rate is maximum midway between the X-line and electron stagnation point. As the guide field increases, it moves towards the electron stagnation point. We motivate how to extend the theory of the location of the stagnation points to include the effect of a guide field. The predictions are compared to two-dimensional (2D) particle-in-cell (PIC) simulations with vastly different guide fields. The simulations have upstream parameters corresponding to three reconnection events observed with MMS. The predictions agree reasonably well with the simulation results, having captured trends with the guide field. The theory correctly predicts that the energy conversion is closer to the X-line in the absolute sense as the guide field increases. The results are then compared to MMS observations, Active Magnetosphere and Planetary Electrodynamics Response Experiment (AMPERE) observations of each event, and global resistive magnetohydrodynamics simulations of the 2015 Oct 16 event. The PIC simulation results agree well with the global observations and simulations, but differ in the strong electric fields and energy conversion rates found in the MMS observations. The results suggest that the strong electric fields observed by MMS do not represent a steady global rate.

  7. Cost-utility Analysis: Thiopurines Plus Endoscopy-guided Biological Step-up Therapy is the Optimal Management of Postoperative Crohn's Disease.

    PubMed

    Candia, Roberto; Naimark, David; Sander, Beate; Nguyen, Geoffrey C

    2017-11-01

    Postoperative recurrence of Crohn's disease is common. This study sought to assess whether the postoperative management should be based on biological therapy alone or combined with thiopurines and whether the therapy should be started immediately after surgery or guided by either endoscopic or clinical recurrence. A Markov model was developed to estimate expected health outcomes in quality-adjusted life years (QALYs) and costs in Canadian dollars (CAD$) accrued by hypothetical patients with high recurrence risk after ileocolic resection. Eight strategies of postoperative management were evaluated. A lifetime time horizon, an annual discount rate of 5%, a societal perspective, and a cost-effectiveness threshold of 50,000 CAD$/QALY were assumed. Deterministic and probabilistic sensitivity analyses were conducted. The model was validated against randomized trials and historical cohorts. Three strategies dominated the others: endoscopy-guided full step-up therapy (14.80 QALYs, CAD$ 462,180), thiopurines immediately post-surgery plus endoscopy-guided biological step-up therapy (14.89 QALYs, CAD$ 464,099) and combination therapy immediately post-surgery (14.94 QALYs, CAD$ 483,685). The second strategy was the most cost-effective, assuming a cost-effectiveness threshold of 50,000 CAD$/QALY. Probabilistic sensitivity analysis showed that the second strategy has the highest probability of being the optimal alternative in all comparisons at cost-effectiveness thresholds from 30,000 to 100,000 CAD$/QALY. The strategies guided only by clinical recurrence and those using biologics alone were dominated. According to this decision analysis, thiopurines immediately after surgery and addition of biologics guided by endoscopic recurrence is the optimal strategy of postoperative management in patients with Crohn's disease with high risk of recurrence (see Video Abstract, Supplemental Digital Content 1, http://links.lww.com/IBD/B654).

  8. Analytical and regression models of glass rod drawing process

    NASA Astrophysics Data System (ADS)

    Alekseeva, L. B.

    2018-03-01

    The process of drawing glass rods (light guides) is being studied. The parameters of the process affecting the quality of the light guide have been determined. To solve the problem, mathematical models based on general equations of continuum mechanics are used. The conditions for the stable flow of the drawing process have been found, which are determined by the stability of the motion of the glass mass in the formation zone to small uncontrolled perturbations. The sensitivity of the formation zone to perturbations of the drawing speed and viscosity is estimated. Experimental models of the drawing process, based on the regression analysis methods, have been obtained. These models make it possible to customize a specific production process to obtain light guides of the required quality. They allow one to find the optimum combination of process parameters in the chosen area and to determine the required accuracy of maintaining them at a specified level.

  9. Development and Integration of Control System Models

    NASA Technical Reports Server (NTRS)

    Kim, Young K.

    1998-01-01

    The computer simulation tool, TREETOPS, has been upgraded and used at NASA/MSFC to model various complicated mechanical systems and to perform their dynamics and control analysis with pointing control systems. A TREETOPS model of Advanced X-ray Astrophysics Facility - Imaging (AXAF-1) dynamics and control system was developed to evaluate the AXAF-I pointing performance for Normal Pointing Mode. An optical model of Shooting Star Experiment (SSE) was also developed and its optical performance analysis was done using the MACOS software.

  10. Frequency guided methods for demodulation of a single fringe pattern.

    PubMed

    Wang, Haixia; Kemao, Qian

    2009-08-17

    Phase demodulation from a single fringe pattern is a challenging task but of interest. A frequency-guided regularized phase tracker and a frequency-guided sequential demodulation method with Levenberg-Marquardt optimization are proposed to demodulate a single fringe pattern. Demodulation path guided by the local frequency from the highest to the lowest is applied in both methods. Since critical points have low local frequency values, they are processed last so that the spurious sign problem caused by these points is avoided. These two methods can be considered as alternatives to the effective fringe follower regularized phase tracker. Demodulation results from one computer-simulated and two experimental fringe patterns using the proposed methods will be demonstrated. (c) 2009 Optical Society of America

  11. FHWA Traffic Noise Model user's guide (version 2.5 addendum)

    DOT National Transportation Integrated Search

    2004-04-30

    In March 1998, the Federal Highway Administration (FHWA), Office of Natural and Human Environment, released the FHWA Traffic Noise Model (TNM), Version 1.0, a state-of-the-art computer model for highway traffic noise prediction and analysis. Since th...

  12. Requirements Management for Net-Centric Enterprises. Phase 1

    DTIC Science & Technology

    2011-04-28

    These include Business Process Modeling Notation ( BPMN ) (White and Miers 2008) and Business Process Execution Language (BPEL) (Sarang, Juric et al...UML: Modeling, Analysis, Design, Morgan Kaufmann/The OMG Press. White, S. A. and D. Miers (2008). BPMN Modeling and Reference Guide, Future

  13. Questions and Answers in Extreme Energy Cosmic Rays - a guide to explore the data set of the Pierre Auger Observatory

    NASA Astrophysics Data System (ADS)

    Abreu, P.; Andringa, S.; Diogo, F.; Espírito Santo, M. C.; Pierre Auger Collaboration

    2016-04-01

    The Pierre Auger Observatory is the largest extensive air shower detector, covering 3000 km2 in Argentina. The Observatory makes available, for educational and outreach purposes, 1% of its cosmic ray data set, corresponding after 10 years of running to more than 35 000 cosmic ray events. Several different proposals of educational activities have been developed within the collaboration and are available. We will focus on the activity guide we developed with the aim of exploring the rich education and outreach potential of cosmic rays with Portuguese high school students. In this guide we use the Auger public data set as a starting point to introduce open questions on the origin, nature and spectrum of high energy cosmic rays. To address them, the students learn about the air-shower cascade development, data reconstruction and its statistical analysis. The guide has been used both in the context of student summer internships at research labs and directly in schools, under the supervision of trained teachers and in close collaboration with Auger researchers. It is now available in Portuguese, English and Spanish.

  14. Effect of visual and tactile feedback on kinematic synergies in the grasping hand.

    PubMed

    Patel, Vrajeshri; Burns, Martin; Vinjamuri, Ramana

    2016-08-01

    The human hand uses a combination of feedforward and feedback mechanisms to accomplish high degree of freedom in grasp control efficiently. In this study, we used a synergy-based control model to determine the effect of sensory feedback on kinematic synergies in the grasping hand. Ten subjects performed two types of grasps: one that included feedback (real) and one without feedback (memory-guided), at two different speeds (rapid and natural). Kinematic synergies were extracted from rapid real and rapid memory-guided grasps using principal component analysis. Synergies extracted from memory-guided grasps revealed greater preservation of natural inter-finger relationships than those found in corresponding synergies extracted from real grasps. Reconstruction of natural real and natural memory-guided grasps was used to test performance and generalizability of synergies. A temporal analysis of reconstruction patterns revealed the differing contribution of individual synergies in real grasps versus memory-guided grasps. Finally, the results showed that memory-guided synergies could not reconstruct real grasps as accurately as real synergies could reconstruct memory-guided grasps. These results demonstrate how visual and tactile feedback affects a closed-loop synergy-based motor control system.

  15. Modeling Canadian Quality Control Test Program for Steroid Hormone Receptors in Breast Cancer: Diagnostic Accuracy Study.

    PubMed

    Pérez, Teresa; Makrestsov, Nikita; Garatt, John; Torlakovic, Emina; Gilks, C Blake; Mallett, Susan

    The Canadian Immunohistochemistry Quality Control program monitors clinical laboratory performance for estrogen receptor and progesterone receptor tests used in breast cancer treatment management in Canada. Current methods assess sensitivity and specificity at each time point, compared with a reference standard. We investigate alternative performance analysis methods to enhance the quality assessment. We used 3 methods of analysis: meta-analysis of sensitivity and specificity of each laboratory across all time points; sensitivity and specificity at each time point for each laboratory; and fitting models for repeated measurements to examine differences between laboratories adjusted by test and time point. Results show 88 laboratories participated in quality control at up to 13 time points using typically 37 to 54 histology samples. In meta-analysis across all time points no laboratories have sensitivity or specificity below 80%. Current methods, presenting sensitivity and specificity separately for each run, result in wide 95% confidence intervals, typically spanning 15% to 30%. Models of a single diagnostic outcome demonstrated that 82% to 100% of laboratories had no difference to reference standard for estrogen receptor and 75% to 100% for progesterone receptor, with the exception of 1 progesterone receptor run. Laboratories with significant differences to reference standard identified with Generalized Estimating Equation modeling also have reduced performance by meta-analysis across all time points. The Canadian Immunohistochemistry Quality Control program has a good design, and with this modeling approach has sufficient precision to measure performance at each time point and allow laboratories with a significantly lower performance to be targeted for advice.

  16. Quantifying and Reducing Curve-Fitting Uncertainty in Isc

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campanelli, Mark; Duck, Benjamin; Emery, Keith

    2015-06-14

    Current-voltage (I-V) curve measurements of photovoltaic (PV) devices are used to determine performance parameters and to establish traceable calibration chains. Measurement standards specify localized curve fitting methods, e.g., straight-line interpolation/extrapolation of the I-V curve points near short-circuit current, Isc. By considering such fits as statistical linear regressions, uncertainties in the performance parameters are readily quantified. However, the legitimacy of such a computed uncertainty requires that the model be a valid (local) representation of the I-V curve and that the noise be sufficiently well characterized. Using more data points often has the advantage of lowering the uncertainty. However, more data pointsmore » can make the uncertainty in the fit arbitrarily small, and this fit uncertainty misses the dominant residual uncertainty due to so-called model discrepancy. Using objective Bayesian linear regression for straight-line fits for Isc, we investigate an evidence-based method to automatically choose data windows of I-V points with reduced model discrepancy. We also investigate noise effects. Uncertainties, aligned with the Guide to the Expression of Uncertainty in Measurement (GUM), are quantified throughout.« less

  17. Quantifying and Reducing Curve-Fitting Uncertainty in Isc: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campanelli, Mark; Duck, Benjamin; Emery, Keith

    Current-voltage (I-V) curve measurements of photovoltaic (PV) devices are used to determine performance parameters and to establish traceable calibration chains. Measurement standards specify localized curve fitting methods, e.g., straight-line interpolation/extrapolation of the I-V curve points near short-circuit current, Isc. By considering such fits as statistical linear regressions, uncertainties in the performance parameters are readily quantified. However, the legitimacy of such a computed uncertainty requires that the model be a valid (local) representation of the I-V curve and that the noise be sufficiently well characterized. Using more data points often has the advantage of lowering the uncertainty. However, more data pointsmore » can make the uncertainty in the fit arbitrarily small, and this fit uncertainty misses the dominant residual uncertainty due to so-called model discrepancy. Using objective Bayesian linear regression for straight-line fits for Isc, we investigate an evidence-based method to automatically choose data windows of I-V points with reduced model discrepancy. We also investigate noise effects. Uncertainties, aligned with the Guide to the Expression of Uncertainty in Measurement (GUM), are quantified throughout.« less

  18. Feature-constrained surface reconstruction approach for point cloud data acquired with 3D laser scanner

    NASA Astrophysics Data System (ADS)

    Wang, Yongbo; Sheng, Yehua; Lu, Guonian; Tian, Peng; Zhang, Kai

    2008-04-01

    Surface reconstruction is an important task in the field of 3d-GIS, computer aided design and computer graphics (CAD & CG), virtual simulation and so on. Based on available incremental surface reconstruction methods, a feature-constrained surface reconstruction approach for point cloud is presented. Firstly features are extracted from point cloud under the rules of curvature extremes and minimum spanning tree. By projecting local sample points to the fitted tangent planes and using extracted features to guide and constrain the process of local triangulation and surface propagation, topological relationship among sample points can be achieved. For the constructed models, a process named consistent normal adjustment and regularization is adopted to adjust normal of each face so that the correct surface model is achieved. Experiments show that the presented approach inherits the convenient implementation and high efficiency of traditional incremental surface reconstruction method, meanwhile, it avoids improper propagation of normal across sharp edges, which means the applicability of incremental surface reconstruction is greatly improved. Above all, appropriate k-neighborhood can help to recognize un-sufficient sampled areas and boundary parts, the presented approach can be used to reconstruct both open and close surfaces without additional interference.

  19. Aircraft/Air Traffic Management Functional Analysis Model: Technical Description. 2.0

    NASA Technical Reports Server (NTRS)

    Etheridge, Melvin; Plugge, Joana; Retina, Nusrat

    1998-01-01

    The Aircraft/Air Traffic Management Functional Analysis Model, Version 2.0 (FAM 2.0), is a discrete event simulation model designed to support analysis of alternative concepts in air traffic management and control. FAM 2.0 was developed by the Logistics Management Institute (LMI) under a National Aeronautics and Space Administration (NASA) contract. This document provides a technical description of FAM 2.0 and its computer files to enable the modeler and programmer to make enhancements or modifications to the model. Those interested in a guide for using the model in analysis should consult the companion document, Aircraft/Air Traffic Management Functional Analysis Model, Version 2.0 Users Manual.

  20. Thermal fixation of swine liver tissue after magnetic resonance-guided high-intensity focused ultrasound ablation.

    PubMed

    Courivaud, Frédéric; Kazaryan, Airazat M; Lund, Alice; Orszagh, Vivian C; Svindland, Aud; Marangos, Irina Pavlik; Halvorsen, Per Steinar; Jebsen, Peter; Fosse, Erik; Hol, Per Kristian; Edwin, Bjørn

    2014-07-01

    The aim of this study was to investigate experimental conditions for efficient and controlled in vivo liver tissue ablation by magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) in a swine model, with the ultimate goal of improving clinical treatment outcome. Histological changes were examined both acutely (four animals) and 1 wk after treatment (five animals). Effects of acoustic power and multiple sonication cycles were investigated. There was good correlation between target size and observed ablation size by thermal dose calculation, post-procedural MR imaging and histopathology, when temperature at the focal point was kept below 90°C. Structural histopathology investigations revealed tissue thermal fixation in ablated regions. In the presence of cavitation, mechanical tissue destruction occurred, resulting in an ablation larger than the target. Complete extra-corporeal MR-guided HIFU ablation in the liver is feasible using high acoustic power. Nearby large vessels were preserved, which makes MR-guided HIFU promising for the ablation of liver tumors adjacent to large veins. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. Modeling the process of interaction of 10 keV electrons with a plane dielectric surface

    NASA Astrophysics Data System (ADS)

    Vokhmyanina, Kristina; Sotnikova, Valentina; Sotnikov, Alexey; Kaplii, Anna; Nikulicheva, Tatyana; Kubankin, Alexandr; Kishin, Ivan

    2018-05-01

    The effect of guiding of charged particles by dielectric channels is of noticeable interest at the present time. The phenomenon is widely studied experimentally and theoretically but some points still need to be clarified. A previously developed model of interaction of fast electrons with dielectric surface at grazing incidence is used to study the independence of electron deflection on the value of electron beam current. The calculations were performed assuming a smooth dependence of the surface conductivity on the beam current in the 40-3000 nA range.

  2. Gyrokinetic and kinetic particle-in-cell simulations of guide-field reconnection. I. Macroscopic effects of the electron flows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muñoz, P. A., E-mail: munozp@mps.mpg.de; Kilian, P.; Büchner, J.

    In this work, we compare gyrokinetic (GK) with fully kinetic Particle-in-Cell (PIC) simulations of magnetic reconnection in the limit of strong guide field. In particular, we analyze the limits of applicability of the GK plasma model compared to a fully kinetic description of force free current sheets for finite guide fields (b{sub g}). Here, we report the first part of an extended comparison, focusing on the macroscopic effects of the electron flows. For a low beta plasma (β{sub i} = 0.01), it is shown that both plasma models develop magnetic reconnection with similar features in the secondary magnetic islands if a sufficientlymore » high guide field (b{sub g} ≳ 30) is imposed in the kinetic PIC simulations. Outside of these regions, in the separatrices close to the X points, the convergence between both plasma descriptions is less restrictive (b{sub g} ≳ 5). Kinetic PIC simulations using guide fields b{sub g} ≲ 30 reveal secondary magnetic islands with a core magnetic field and less energetic flows inside of them in comparison to the GK or kinetic PIC runs with stronger guide fields. We find that these processes are mostly due to an initial shear flow absent in the GK initialization and negligible in the kinetic PIC high guide field regime, in addition to fast outflows on the order of the ion thermal speed that violate the GK ordering. Since secondary magnetic islands appear after the reconnection peak time, a kinetic PIC/GK comparison is more accurate in the linear phase of magnetic reconnection. For a high beta plasma (β{sub i} = 1.0) where reconnection rates and fluctuations levels are reduced, similar processes happen in the secondary magnetic islands in the fully kinetic description, but requiring much lower guide fields (b{sub g} ≲ 3)« less

  3. Master Control--How Kids Can Control the Impact of TV, and Enjoy It More Than Ever! A Classroom Guide.

    ERIC Educational Resources Information Center

    1994

    This classroom guide and "Better Viewing" guide accompany a 28-minute videotape on television literacy called "Master Control." The classroom guide explains the purpose behind the video, pointing out that "Master Control" is not about doing away with TV, but about a youngster's getting the most out of his or her TV…

  4. BASINs and WEPP Climate Assessment Tools (CAT): Case ...

    EPA Pesticide Factsheets

    EPA announced the release of the final report, BASINs and WEPP Climate Assessment Tools (CAT): Case Study Guide to Potential Applications. This report supports application of two recently developed water modeling tools, the Better Assessment Science Integrating point & Non-point Sources (BASINS) and the Water Erosion Prediction Project Climate Assessment Tool (WEPPCAT). The report presents a series of short case studies designed to illustrate the capabilities of these tools for conducting scenario based assessments of the potential effects of climate change on streamflow and water quality. This report presents a series of short, illustrative case studies using the BASINS and WEPP climate assessment tools.

  5. The Surgical Mortality Probability Model: derivation and validation of a simple risk prediction rule for noncardiac surgery.

    PubMed

    Glance, Laurent G; Lustik, Stewart J; Hannan, Edward L; Osler, Turner M; Mukamel, Dana B; Qian, Feng; Dick, Andrew W

    2012-04-01

    To develop a 30-day mortality risk index for noncardiac surgery that can be used to communicate risk information to patients and guide clinical management at the "point-of-care," and that can be used by surgeons and hospitals to internally audit their quality of care. Clinicians rely on the Revised Cardiac Risk Index to quantify the risk of cardiac complications in patients undergoing noncardiac surgery. Because mortality from noncardiac causes accounts for many perioperative deaths, there is also a need for a simple bedside risk index to predict 30-day all-cause mortality after noncardiac surgery. Retrospective cohort study of 298,772 patients undergoing noncardiac surgery during 2005 to 2007 using the American College of Surgeons National Surgical Quality Improvement Program database. The 9-point S-MPM (Surgical Mortality Probability Model) 30-day mortality risk index was derived empirically and includes three risk factors: ASA (American Society of Anesthesiologists) physical status, emergency status, and surgery risk class. Patients with ASA physical status I, II, III, IV or V were assigned either 0, 2, 4, 5, or 6 points, respectively; intermediate- or high-risk procedures were assigned 1 or 2 points, respectively; and emergency procedures were assigned 1 point. Patients with risk scores less than 5 had a predicted risk of mortality less than 0.50%, whereas patients with a risk score of 5 to 6 had a risk of mortality between 1.5% and 4.0%. Patients with a risk score greater than 6 had risk of mortality more than 10%. S-MPM exhibited excellent discrimination (C statistic, 0.897) and acceptable calibration (Hosmer-Lemeshow statistic 13.0, P = 0.023) in the validation data set. Thirty-day mortality after noncardiac surgery can be accurately predicted using a simple and accurate risk score based on information readily available at the bedside. This risk index may play a useful role in facilitating shared decision making, developing and implementing risk-reduction strategies, and guiding quality improvement efforts.

  6. Model-based decision making in early clinical development: minimizing the impact of a blood pressure adverse event.

    PubMed

    Stroh, Mark; Addy, Carol; Wu, Yunhui; Stoch, S Aubrey; Pourkavoos, Nazaneen; Groff, Michelle; Xu, Yang; Wagner, John; Gottesdiener, Keith; Shadle, Craig; Wang, Hong; Manser, Kimberly; Winchell, Gregory A; Stone, Julie A

    2009-03-01

    We describe how modeling and simulation guided program decisions following a randomized placebo-controlled single-rising oral dose first-in-man trial of compound A where an undesired transient blood pressure (BP) elevation occurred in fasted healthy young adult males. We proposed a lumped-parameter pharmacokinetic-pharmacodynamic (PK/PD) model that captured important aspects of the BP homeostasis mechanism. Four conceptual units characterized the feedback PD model: a sinusoidal BP set point, an effect compartment, a linear effect model, and a system response. To explore approaches for minimizing the BP increase, we coupled the PD model to a modified PK model to guide oral controlled-release (CR) development. The proposed PK/PD model captured the central tendency of the observed data. The simulated BP response obtained with theoretical release rate profiles suggested some amelioration of the peak BP response with CR. This triggered subsequent CR formulation development; we used actual dissolution data from these candidate CR formulations in the PK/PD model to confirm a potential benefit in the peak BP response. Though this paradigm has yet to be tested in the clinic, our model-based approach provided a common rational framework to more fully utilize the limited available information for advancing the program.

  7. Curriculum Guide, C.E.I.T.--Ninth Grade, Transportation Technology. Point Pleasant Junior High School, Point Pleasant, West Virginia, 1977-1978.

    ERIC Educational Resources Information Center

    Kleine, Richard E.; Hamme, Randall

    The result of a curriculum development project known as Project Open, this curriculum guide offers an elective course on transportation systems for ninth graders who are participating in the Career Exploration in Technology (CEIT) program and who have completed the eighth-grade course on manufacturing systems. The course, which spans two…

  8. Traffic analysis toolbox volume IX : work zone modeling and simulation, a guide for analysts

    DOT National Transportation Integrated Search

    2009-03-01

    This document is the second volume in the FHWA Traffic Analysis Toolbox: Work Zone Analysis series. Whereas the first volume provides guidance to decision-makers at agencies and jurisdictions considering the role of analytical tools in work zone plan...

  9. rpe v5: an emulator for reduced floating-point precision in large numerical simulations

    NASA Astrophysics Data System (ADS)

    Dawson, Andrew; Düben, Peter D.

    2017-06-01

    This paper describes the rpe (reduced-precision emulator) library which has the capability to emulate the use of arbitrary reduced floating-point precision within large numerical models written in Fortran. The rpe software allows model developers to test how reduced floating-point precision affects the result of their simulations without having to make extensive code changes or port the model onto specialized hardware. The software can be used to identify parts of a program that are problematic for numerical precision and to guide changes to the program to allow a stronger reduction in precision.The development of rpe was motivated by the strong demand for more computing power. If numerical precision can be reduced for an application under consideration while still achieving results of acceptable quality, computational cost can be reduced, since a reduction in numerical precision may allow an increase in performance or a reduction in power consumption. For simulations with weather and climate models, savings due to a reduction in precision could be reinvested to allow model simulations at higher spatial resolution or complexity, or to increase the number of ensemble members to improve predictions. rpe was developed with a particular focus on the community of weather and climate modelling, but the software could be used with numerical simulations from other domains.

  10. An Alternative Methodological Approach for Cost-Effectiveness Analysis and Decision Making in Genomic Medicine.

    PubMed

    Fragoulakis, Vasilios; Mitropoulou, Christina; van Schaik, Ron H; Maniadakis, Nikolaos; Patrinos, George P

    2016-05-01

    Genomic Medicine aims to improve therapeutic interventions and diagnostics, the quality of life of patients, but also to rationalize healthcare costs. To reach this goal, careful assessment and identification of evidence gaps for public health genomics priorities are required so that a more efficient healthcare environment is created. Here, we propose a public health genomics-driven approach to adjust the classical healthcare decision making process with an alternative methodological approach of cost-effectiveness analysis, which is particularly helpful for genomic medicine interventions. By combining classical cost-effectiveness analysis with budget constraints, social preferences, and patient ethics, we demonstrate the application of this model, the Genome Economics Model (GEM), based on a previously reported genome-guided intervention from a developing country environment. The model and the attendant rationale provide a practical guide by which all major healthcare stakeholders could ensure the sustainability of funding for genome-guided interventions, their adoption and coverage by health insurance funds, and prioritization of Genomic Medicine research, development, and innovation, given the restriction of budgets, particularly in developing countries and low-income healthcare settings in developed countries. The implications of the GEM for the policy makers interested in Genomic Medicine and new health technology and innovation assessment are also discussed.

  11. A step-by-step guide to systematically identify all relevant animal studies.

    PubMed

    Leenaars, Marlies; Hooijmans, Carlijn R; van Veggel, Nieky; ter Riet, Gerben; Leeflang, Mariska; Hooft, Lotty; van der Wilt, Gert Jan; Tillema, Alice; Ritskes-Hoitinga, Merel

    2012-01-01

    Before starting a new animal experiment, thorough analysis of previously performed experiments is essential from a scientific as well as from an ethical point of view. The method that is most suitable to carry out such a thorough analysis of the literature is a systematic review (SR). An essential first step in an SR is to search and find all potentially relevant studies. It is important to include all available evidence in an SR to minimize bias and reduce hampered interpretation of experimental outcomes. Despite the recent development of search filters to find animal studies in PubMed and EMBASE, searching for all available animal studies remains a challenge. Available guidelines from the clinical field cannot be copied directly to the situation within animal research, and although there are plenty of books and courses on searching the literature, there is no compact guide available to search and find relevant animal studies. Therefore, in order to facilitate a structured, thorough and transparent search for animal studies (in both preclinical and fundamental science), an easy-to-use, step-by-step guide was prepared and optimized using feedback from scientists in the field of animal experimentation. The step-by-step guide will assist scientists in performing a comprehensive literature search and, consequently, improve the scientific quality of the resulting review and prevent unnecessary animal use in the future.

  12. A step-by-step guide to systematically identify all relevant animal studies

    PubMed Central

    Leenaars, Marlies; Hooijmans, Carlijn R; van Veggel, Nieky; ter Riet, Gerben; Leeflang, Mariska; Hooft, Lotty; van der Wilt, Gert Jan; Tillema, Alice; Ritskes-Hoitinga, Merel

    2012-01-01

    Before starting a new animal experiment, thorough analysis of previously performed experiments is essential from a scientific as well as from an ethical point of view. The method that is most suitable to carry out such a thorough analysis of the literature is a systematic review (SR). An essential first step in an SR is to search and find all potentially relevant studies. It is important to include all available evidence in an SR to minimize bias and reduce hampered interpretation of experimental outcomes. Despite the recent development of search filters to find animal studies in PubMed and EMBASE, searching for all available animal studies remains a challenge. Available guidelines from the clinical field cannot be copied directly to the situation within animal research, and although there are plenty of books and courses on searching the literature, there is no compact guide available to search and find relevant animal studies. Therefore, in order to facilitate a structured, thorough and transparent search for animal studies (in both preclinical and fundamental science), an easy-to-use, step-by-step guide was prepared and optimized using feedback from scientists in the field of animal experimentation. The step-by-step guide will assist scientists in performing a comprehensive literature search and, consequently, improve the scientific quality of the resulting review and prevent unnecessary animal use in the future. PMID:22037056

  13. Satellite Power Systems (SPS) concept definition study, exhibit C. Volume 7: System/subsystem requirements data book

    NASA Technical Reports Server (NTRS)

    Hanley, G. M.

    1979-01-01

    Volume 7 of the Satellite Power Systems (SPS) Concept Definition Study final report summarizes the basic requirements used as a guide to systems analysis and is a basis for the selection of candidate SPS point design(s). Initially, these collected data reflected the level of definition resulting from the evaluation of a broad spectrum of SPS concepts. As the various concepts matured these requirements were updated to reflect the requirements identified for the projected satellite system/subsystem point design(s). The identified subsystem/systems requirements are defined, and where appropriate, recommendations for alternate approaches which may represent improved design features are presented. A more detailed discussion of the selected point design(s) will be found in Volume 2 of this report.

  14. A practical guide to self-sustaining point-of-care ultrasound education programs in resource-limited settings.

    PubMed

    Henwood, Patricia C; Mackenzie, David C; Rempell, Joshua S; Murray, Alice F; Leo, Megan M; Dean, Anthony J; Liteplo, Andrew S; Noble, Vicki E

    2014-09-01

    The value of point-of-care ultrasound education in resource-limited settings is increasingly recognized, though little guidance exists on how to best construct a sustainable training program. Herein we offer a practical overview of core factors to consider when developing and implementing a point-of-care ultrasound education program in a resource-limited setting. Considerations include analysis of needs assessment findings, development of locally relevant curriculum, access to ultrasound machines and related technological and financial resources, quality assurance and follow-up plans, strategic partnerships, and outcomes measures. Well-planned education programs in these settings increase the potential for long-term influence on clinician skills and patient care. Copyright © 2014 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  15. Body-mounted robotic instrument guide for image-guided cryotherapy of renal cancer

    PubMed Central

    Hata, Nobuhiko; Song, Sang-Eun; Olubiyi, Olutayo; Arimitsu, Yasumichi; Fujimoto, Kosuke; Kato, Takahisa; Tuncali, Kemal; Tani, Soichiro; Tokuda, Junichi

    2016-01-01

    Purpose: Image-guided cryotherapy of renal cancer is an emerging alternative to surgical nephrectomy, particularly for those who cannot sustain the physical burden of surgery. It is well known that the outcome of this therapy depends on the accurate placement of the cryotherapy probe. Therefore, a robotic instrument guide may help physicians aim the cryotherapy probe precisely to maximize the efficacy of the treatment and avoid damage to critical surrounding structures. The objective of this paper was to propose a robotic instrument guide for orienting cryotherapy probes in image-guided cryotherapy of renal cancers. The authors propose a body-mounted robotic guide that is expected to be less susceptible to guidance errors caused by the patient’s whole body motion. Methods: Keeping the device’s minimal footprint in mind, the authors developed and validated a body-mounted, robotic instrument guide that can maintain the geometrical relationship between the device and the patient’s body, even in the presence of the patient’s frequent body motions. The guide can orient the cryotherapy probe with the skin incision point as the remote-center-of-motion. The authors’ validation studies included an evaluation of the mechanical accuracy and position repeatability of the robotic instrument guide. The authors also performed a mock MRI-guided cryotherapy procedure with a phantom to compare the advantage of robotically assisted probe replacements over a free-hand approach, by introducing organ motions to investigate their effects on the accurate placement of the cryotherapy probe. Measurements collected for performance analysis included accuracy and time taken for probe placements. Multivariate analysis was performed to assess if either or both organ motion and the robotic guide impacted these measurements. Results: The mechanical accuracy and position repeatability of the probe placement using the robotic instrument guide were 0.3 and 0.1 mm, respectively, at a depth of 80 mm. The phantom test indicated that the accuracy of probe placement was significantly better with the robotic instrument guide (4.1 mm) than without the guide (6.3 mm, p<0.001), even in the presence of body motion. When independent organ motion was artificially added, in addition to body motion, the advantage of accurate probe placement using the robotic instrument guide disappeared statistically [i.e., 6.0 mm with the robotic guide and 5.9 mm without the robotic guide (p = 0.906)]. When the robotic instrument guide was used, the total time required to complete the procedure was reduced from 19.6 to 12.7 min (p<0.001). Multivariable analysis indicated that the robotic instrument guide, not the organ motion, was the cause of statistical significance. The statistical power the authors obtained was 88% in accuracy assessment and 99% higher in duration measurement. Conclusions: The body-mounted robotic instrument guide allows positioning of the probe during image-guided cryotherapy of renal cancer and was done in fewer attempts and in less time than the free-hand approach. The accuracy of the placement of the cryotherapy probe was better using the robotic instrument guide than without the guide when no organ motion was present. The accuracy between the robotic and free-hand approach becomes comparable when organ motion was present. PMID:26843245

  16. Algorithm for cellular reprogramming.

    PubMed

    Ronquist, Scott; Patterson, Geoff; Muir, Lindsey A; Lindsly, Stephen; Chen, Haiming; Brown, Markus; Wicha, Max S; Bloch, Anthony; Brockett, Roger; Rajapakse, Indika

    2017-11-07

    The day we understand the time evolution of subcellular events at a level of detail comparable to physical systems governed by Newton's laws of motion seems far away. Even so, quantitative approaches to cellular dynamics add to our understanding of cell biology. With data-guided frameworks we can develop better predictions about, and methods for, control over specific biological processes and system-wide cell behavior. Here we describe an approach for optimizing the use of transcription factors (TFs) in cellular reprogramming, based on a device commonly used in optimal control. We construct an approximate model for the natural evolution of a cell-cycle-synchronized population of human fibroblasts, based on data obtained by sampling the expression of 22,083 genes at several time points during the cell cycle. To arrive at a model of moderate complexity, we cluster gene expression based on division of the genome into topologically associating domains (TADs) and then model the dynamics of TAD expression levels. Based on this dynamical model and additional data, such as known TF binding sites and activity, we develop a methodology for identifying the top TF candidates for a specific cellular reprogramming task. Our data-guided methodology identifies a number of TFs previously validated for reprogramming and/or natural differentiation and predicts some potentially useful combinations of TFs. Our findings highlight the immense potential of dynamical models, mathematics, and data-guided methodologies for improving strategies for control over biological processes. Copyright © 2017 the Author(s). Published by PNAS.

  17. A computational model to compare different investment scenarios for mini-stereotactic frame approach to deep brain stimulation surgery.

    PubMed

    Lanotte, M; Cavallo, M; Franzini, A; Grifi, M; Marchese, E; Pantaleoni, M; Piacentino, M; Servello, D

    2010-09-01

    Deep brain stimulation (DBS) alleviates symptoms of many neurological disorders by applying electrical impulses to the brain by means of implanted electrodes, generally put in place using a conventional stereotactic frame. A new image guided disposable mini-stereotactic system has been designed to help shorten and simplify DBS procedures when compared to standard stereotaxy. A small number of studies have been conducted which demonstrate localization accuracies of the system similar to those achievable by the conventional frame. However no data are available to date on the economic impact of this new frame. The aim of this paper was to develop a computational model to evaluate the investment required to introduce the image guided mini-stereotactic technology for stereotactic DBS neurosurgery. A standard DBS patient care pathway was developed and related costs were analyzed. A differential analysis was conducted to capture the impact of introducing the image guided system on the procedure workflow. The analysis was carried out in five Italian neurosurgical centers. A computational model was developed to estimate upfront investments and surgery costs leading to a definition of the best financial option to introduce the new frame. Investments may vary from Euro 1.900 (purchasing of Image Guided [IG] mini-stereotactic frame only) to Euro 158.000.000. Moreover the model demonstrates how the introduction of the IG mini-stereotactic frame doesn't substantially affect the DBS procedure costs.

  18. Comparative ergonomic workflow and user experience analysis of MRI versus fluoroscopy-guided vascular interventions: an iliac angioplasty exemplar case study.

    PubMed

    Fernández-Gutiérrez, Fabiola; Martínez, Santiago; Rube, Martin A; Cox, Benjamin F; Fatahi, Mahsa; Scott-Brown, Kenneth C; Houston, J Graeme; McLeod, Helen; White, Richard D; French, Karen; Gueorguieva, Mariana; Immel, Erwin; Melzer, Andreas

    2015-10-01

    A methodological framework is introduced to assess and compare a conventional fluoroscopy protocol for peripheral angioplasty with a new magnetic resonant imaging (MRI)-guided protocol. Different scenarios were considered during interventions on a perfused arterial phantom with regard to time-based and cognitive task analysis, user experience and ergonomics. Three clinicians with different expertise performed a total of 43 simulated common iliac angioplasties (9 fluoroscopic, 34 MRI-guided) in two blocks of sessions. Six different configurations for MRI guidance were tested in the first block. Four of them were evaluated in the second block and compared to the fluoroscopy protocol. Relevant stages' durations were collected, and interventions were audio-visually recorded from different perspectives. A cued retrospective protocol analysis (CRPA) was undertaken, including personal interviews. In addition, ergonomic constraints in the MRI suite were evaluated. Significant differences were found when comparing the performance between MRI configurations versus fluoroscopy. Two configurations [with times of 8.56 (0.64) and 9.48 (1.13) min] led to reduce procedure time for MRI guidance, comparable to fluoroscopy [8.49 (0.75) min]. The CRPA pointed out the main influential factors for clinical procedure performance. The ergonomic analysis quantified musculoskeletal risks for interventional radiologists when utilising MRI. Several alternatives were suggested to prevent potential low-back injuries. This work presents a step towards the implementation of efficient operational protocols for MRI-guided procedures based on an integral and multidisciplinary framework, applicable to the assessment of current vascular protocols. The use of first-user perspective raises the possibility of establishing new forms of clinical training and education.

  19. Minimally invasive positioning robot system of femoral neck hollow screw implants based on x-ray error correction

    NASA Astrophysics Data System (ADS)

    Zou, Yunpeng; Xu, Ying; Hu, Lei; Guo, Na; Wang, Lifeng

    2017-01-01

    Aiming the high failure rate, the high radiation quantity and the poor positioning accuracy of femoral neck traditional surgery, this article develops a set of new positioning robot system of femoral neck hollow screw implants based on X-rays error correction, which bases on the study of x-rays perspective principle and the Motion Principle of 6 DOF(degree of freedom) series robot UR(Universal Robots). Compared with Computer Assisted Navigation System, this system owns better positioning accuracy and more simple operation. In addition, without extra Equipment of Visual Tracking, this system can reduce a lot of cost. During the surgery, Doctor can plan the operation path and the pose of mark needle according to the positive and lateral X-rays images of patients. Then they can calculate the pixel ratio according to the ratio of the actual length of mark line and the length on image. After that, they can calculate the amount of exercise of UR Robot according to the relative position between operation path and guide pin and the fixed relationship between guide pin and UR robot. Then, they can control UR to drive the positioning guide pin to the operation path. At this point, check the positioning guide pin and the planning path is coincident, if not, repeat the previous steps, until the positioning guide pin and the planning path coincide which will eventually complete the positioning operation. Moreover, to verify the positioning accuracy, this paper make an errors analysis aiming to thirty cases of the experimental model of bone. The result shows that the motion accuracy of the UR Robot is 0.15mm and the Integral error precision is within 0.8mm. To verify the clinical feasibility of this system, this article analysis on three cases of the clinical experiment. In the whole process of positioning, the X-rays irradiation time is 2-3s, the number of perspective is 3-5 and the whole positioning time is 7-10min. The result shows that this system can complete accurately femoral neck positioning surgery. Meanwhile, it can greatly reduce the X-rays radiation of medical staff and patients. To summarize, it has a significant value in clinical application.

  20. Patient-specific core decompression surgery for early-stage ischemic necrosis of the femoral head

    PubMed Central

    Wang, Wei; Hu, Wei; Yang, Pei; Dang, Xiao Qian; Li, Xiao Hui; Wang, Kun Zheng

    2017-01-01

    Introduction Core decompression is an efficient treatment for early stage ischemic necrosis of the femoral head. In conventional procedures, the pre-operative X-ray only shows one plane of the ischemic area, which often results in inaccurate drilling. This paper introduces a new method that uses computer-assisted technology and rapid prototyping to enhance drilling accuracy during core decompression surgeries and presents a validation study of cadaveric tests. Methods Twelve cadaveric human femurs were used to simulate early-stage ischemic necrosis. The core decompression target at the anterolateral femoral head was simulated using an embedded glass ball (target). Three positioning Kirschner wires were drilled into the top and bottom of the large rotor. The specimen was then subjected to computed tomography (CT). A CT image of the specimen was imported into the Mimics software to construct a three-dimensional model including the target. The best core decompression channel was then designed using the 3D model. A navigational template for the specimen was designed using the Pro/E software and manufactured by rapid prototyping technology to guide the drilling channel. The specimen-specific navigation template was installed on the specimen using positioning Kirschner wires. Drilling was performed using a guide needle through the guiding hole on the templates. The distance between the end point of the guide needle and the target was measured to validate the patient-specific surgical accuracy. Results The average distance between the tip of the guide needle drilled through the guiding template and the target was 1.92±0.071 mm. Conclusions Core decompression using a computer-rapid prototyping template is a reliable and accurate technique that could provide a new method of precision decompression for early-stage ischemic necrosis. PMID:28464029

  1. Patient-specific core decompression surgery for early-stage ischemic necrosis of the femoral head.

    PubMed

    Wang, Wei; Hu, Wei; Yang, Pei; Dang, Xiao Qian; Li, Xiao Hui; Wang, Kun Zheng

    2017-01-01

    Core decompression is an efficient treatment for early stage ischemic necrosis of the femoral head. In conventional procedures, the pre-operative X-ray only shows one plane of the ischemic area, which often results in inaccurate drilling. This paper introduces a new method that uses computer-assisted technology and rapid prototyping to enhance drilling accuracy during core decompression surgeries and presents a validation study of cadaveric tests. Twelve cadaveric human femurs were used to simulate early-stage ischemic necrosis. The core decompression target at the anterolateral femoral head was simulated using an embedded glass ball (target). Three positioning Kirschner wires were drilled into the top and bottom of the large rotor. The specimen was then subjected to computed tomography (CT). A CT image of the specimen was imported into the Mimics software to construct a three-dimensional model including the target. The best core decompression channel was then designed using the 3D model. A navigational template for the specimen was designed using the Pro/E software and manufactured by rapid prototyping technology to guide the drilling channel. The specimen-specific navigation template was installed on the specimen using positioning Kirschner wires. Drilling was performed using a guide needle through the guiding hole on the templates. The distance between the end point of the guide needle and the target was measured to validate the patient-specific surgical accuracy. The average distance between the tip of the guide needle drilled through the guiding template and the target was 1.92±0.071 mm. Core decompression using a computer-rapid prototyping template is a reliable and accurate technique that could provide a new method of precision decompression for early-stage ischemic necrosis.

  2. An Analysis of a Comprehensive Evaluation Model for Guided Group Interaction Techniques with Juvenile Delinquents. Final Report.

    ERIC Educational Resources Information Center

    Silverman, Mitchell

    Reported are the first phase activities of a longitudinal project designed to evaluate the effectiveness of Guided Group Interaction (GGI) technique as a meaningful approach in the field of corrections. The main findings relate to the establishment of reliability for the main components of the Revised Behavior Scores System developed to assess the…

  3. Optimizing the interpretation of CT for appendicitis: modeling health utilities for clinical practice.

    PubMed

    Blackmore, C Craig; Terasawa, Teruhiko

    2006-02-01

    Error in radiology can be reduced by standardizing the interpretation of imaging studies to the optimum sensitivity and specificity. In this report, the authors demonstrate how the optimal interpretation of appendiceal computed tomography (CT) can be determined and how it varies in different clinical scenarios. Utility analysis and receiver operating characteristic (ROC) curve modeling were used to determine the trade-off between false-positive and false-negative test results to determine the optimal operating point on the ROC curve for the interpretation of appendicitis CT. Modeling was based on a previous meta-analysis for the accuracy of CT and on literature estimates of the utilities of various health states. The posttest probability of appendicitis was derived using Bayes's theorem. At a low prevalence of disease (screening), appendicitis CT should be interpreted at high specificity (97.7%), even at the expense of lower sensitivity (75%). Conversely, at a high probability of disease, high sensitivity (97.4%) is preferred (specificity 77.8%). When the clinical diagnosis of appendicitis is equivocal, CT interpretation should emphasize both sensitivity and specificity (sensitivity 92.3%, specificity 91.5%). Radiologists can potentially decrease medical error and improve patient health by varying the interpretation of appendiceal CT on the basis of the clinical probability of appendicitis. This report is an example of how utility analysis can be used to guide radiologists in the interpretation of imaging studies and provide guidance on appropriate targets for the standardization of interpretation.

  4. Accuracy of computer-guided implantation in a human cadaver model.

    PubMed

    Yatzkair, Gustavo; Cheng, Alice; Brodie, Stan; Raviv, Eli; Boyan, Barbara D; Schwartz, Zvi

    2015-10-01

    To examine the accuracy of computer-guided implantation using a human cadaver model with reduced experimental variability. Twenty-eight (28) dental implants representing 12 clinical cases were placed in four cadaver heads using a static guided implantation template. All planning and surgeries were performed by one clinician. All radiographs and measurements were performed by two examiners. The distance of the implants from buccal and lingual bone and mesial implant or tooth was analyzed at the apical and coronal levels, and measurements were compared to the planned values. No significant differences were seen between planned and implanted measurements. Average deviation of an implant from its planning radiograph was 0.8 mm, which is within the range of variability expected from CT analysis. Guided implantation can be used safely with a margin of error of 1 mm. © 2014 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.

  5. Ultrasonography in Acupuncture-Uses in Education and Research.

    PubMed

    Leow, Mabel Qi He; Cui, Shu Li; Mohamed Shah, Mohammad Taufik Bin; Cao, Taige; Tay, Shian Chao; Tay, Peter Kay Chai; Ooi, Chin Chin

    2017-06-01

    This study aims to explore the potential use of ultrasound in locating the second posterior sacral foramen acupuncture point, quantifying depth of insertion and describing surrounding anatomical structures. We performed acupuncture needle insertion on a study team member. There were four steps in our experiment. First, the acupuncturist located the acupuncture point by palpation. Second, we used an ultrasound machine to visualize the structures surrounding the location of the acupuncture point and measure the depth required for needle insertion. Third, the acupuncturist inserted the acupuncture needle into the acupuncture point at an angle of 30°. Fourth, we performed another ultrasound scan to ensure that the needle was in the desired location. Results suggested that ultrasound could be used to locate the acupuncture point and estimate the depth of needle insertion. The needle was inserted to a depth of 4.0 cm to reach the surface of the sacral foramen. Based on Pythagoras theorem, taking a needle insertion angle of 30° and a needle insertion depth of 4.0 cm, the estimated perpendicular depth is 1.8 cm. An ultrasound scan corroborated the depth of 1.85 cm. The use of an ultrasound-guided technique for needle insertion in acupuncture practice could help standardize the treatment. Clinicians and students would be able to visualize and measure the depth of the sacral foramen acupuncture point, to guide the depth of needle insertion. This methodological guide could also be used to create a standard treatment protocol for research. A similar mathematical guide could also be created for other acupuncture points in future. Copyright © 2017. Published by Elsevier B.V.

  6. Experimental and computational models of neurite extension at a choice point in response to controlled diffusive gradients

    NASA Astrophysics Data System (ADS)

    Catig, G. C.; Figueroa, S.; Moore, M. J.

    2015-08-01

    Ojective. Axons are guided toward desired targets through a series of choice points that they navigate by sensing cues in the cellular environment. A better understanding of how microenvironmental factors influence neurite growth during development can inform strategies to address nerve injury. Therefore, there is a need for biomimetic models to systematically investigate the influence of guidance cues at such choice points. Approach. We ran an adapted in silico biased turning axon growth model under the influence of nerve growth factor (NGF) and compared the results to corresponding in vitro experiments. We examined if growth simulations were predictive of neurite population behavior at a choice point. We used a biphasic micropatterned hydrogel system consisting of an outer cell restrictive mold that enclosed a bifurcated cell permissive region and placed a well near a bifurcating end to allow proteins to diffuse and form a gradient. Experimental diffusion profiles in these constructs were used to validate a diffusion computational model that utilized experimentally measured diffusion coefficients in hydrogels. The computational diffusion model was then used to establish defined soluble gradients within the permissive region of the hydrogels and maintain the profiles in physiological ranges for an extended period of time. Computational diffusion profiles informed the neurite growth model, which was compared with neurite growth experiments in the bifurcating hydrogel constructs. Main results. Results indicated that when applied to the constrained choice point geometry, the biased turning model predicted experimental behavior closely. Results for both simulated and in vitro neurite growth studies showed a significant chemoattractive response toward the bifurcated end containing an NGF gradient compared to the control, though some neurites were found in the end with no NGF gradient. Significance. The integrated model of neurite growth we describe will allow comparison of experimental studies against growth cone guidance computational models applied to axon pathfinding at choice points.

  7. Point of care information services: a platform for self-directed continuing medical education for front line decision makers

    PubMed Central

    Moja, Lorenzo; Kwag, Koren Hyogene

    2015-01-01

    The structure and aim of continuing medical education (CME) is shifting from the passive transmission of knowledge to a competency-based model focused on professional development. Self-directed learning is emerging as the foremost educational method for advancing competency-based CME. In a field marked by the constant expansion of knowledge, self-directed learning allows physicians to tailor their learning strategy to meet the information needs of practice. Point of care information services are innovative tools that provide health professionals with digested evidence at the front line to guide decision making. By mobilising self-directing learning to meet the information needs of clinicians at the bedside, point of care information services represent a promising platform for competency-based CME. Several points, however, must be considered to enhance the accessibility and development of these tools to improve competency-based CME and the quality of care. PMID:25655251

  8. Accuracy of Novel Computed Tomography-Guided Frameless Stereotactic Drilling and Catheter System in Human Cadavers.

    PubMed

    Sankey, Eric W; Butler, Eric; Sampson, John H

    2017-10-01

    To evaluate accuracy of a computed tomography (CT)-guided frameless stereotactic drilling and catheter system. A prospective, single-arm study was performed using human cadaver heads to evaluate placement accuracy of a novel, flexible intracranial catheter and stabilizing bone anchor system and drill kit. There were 20 catheter placements included in the analysis. The primary endpoint was accuracy of catheter tip location on intraoperative CT. Secondary endpoints included target registration error and entry and target point error before and after drilling. Measurements are reported as mean ± SD (median, range). Target registration error was 0.46 mm ± 0.26 (0.50 mm, -1.00 to 1.00 mm). Two (10%) target point trajectories were negatively impacted by drilling. Intracranial catheter depth was 59.8 mm ± 9.4 (60.5 mm, 38.0-80.0 mm). Drilling angle was 22° ± 9 (21°, 7°-45°). Deviation between planned and actual entry point on CT was 1.04 mm ± 0.38 (1.00 mm, 0.40-2.00 mm). Deviation between planned and actual target point on CT was 1.60 mm ± 0.98 (1.40 mm, 0.40-4.00 mm). No correlation was observed between intracranial catheter depth and target point deviation (accuracy) (Pearson coefficient 0.018) or between technician experience and accuracy (Pearson coefficient 0.020). There was no significant difference in accuracy with trajectories performed for different cadaver heads (P = 0.362). Highly accurate catheter placement is achievable using this novel flexible catheter and bone anchor system placed via frameless stereotaxy, with an average deviation between planned and actual target point of 1.60 mm ± 0.98 (1.40 mm, 0.40-4.00 mm). Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Floquet stability analysis of the longitudinal dynamics of two hovering model insects

    PubMed Central

    Wu, Jiang Hao; Sun, Mao

    2012-01-01

    Because of the periodically varying aerodynamic and inertial forces of the flapping wings, a hovering or constant-speed flying insect is a cyclically forcing system, and, generally, the flight is not in a fixed-point equilibrium, but in a cyclic-motion equilibrium. Current stability theory of insect flight is based on the averaged model and treats the flight as a fixed-point equilibrium. In the present study, we treated the flight as a cyclic-motion equilibrium and used the Floquet theory to analyse the longitudinal stability of insect flight. Two hovering model insects were considered—a dronefly and a hawkmoth. The former had relatively high wingbeat frequency and small wing-mass to body-mass ratio, and hence very small amplitude of body oscillation; while the latter had relatively low wingbeat frequency and large wing-mass to body-mass ratio, and hence relatively large amplitude of body oscillation. For comparison, analysis using the averaged-model theory (fixed-point stability analysis) was also made. Results of both the cyclic-motion stability analysis and the fixed-point stability analysis were tested by numerical simulation using complete equations of motion coupled with the Navier–Stokes equations. The Floquet theory (cyclic-motion stability analysis) agreed well with the simulation for both the model dronefly and the model hawkmoth; but the averaged-model theory gave good results only for the dronefly. Thus, for an insect with relatively large body oscillation at wingbeat frequency, cyclic-motion stability analysis is required, and for their control analysis, the existing well-developed control theories for systems of fixed-point equilibrium are no longer applicable and new methods that take the cyclic variation of the flight dynamics into account are needed. PMID:22491980

  10. Spreadsheet-based engine data analysis tool - user's guide.

    DOT National Transportation Integrated Search

    2016-07-01

    This record refers to both the spreadsheet tool - Fleet Equipment Performance Measurement Preventive Maintenance Model: Spreadsheet-Based Engine Data Analysis Tool, http://ntl.bts.gov/lib/60000/60000/60007/0-6626-P1_Final.xlsm - and its accompanying ...

  11. A quantitative comparison of physiologic indicators of cardiopulmonary resuscitation quality: Diastolic blood pressure versus end-tidal carbon dioxide.

    PubMed

    Morgan, Ryan W; French, Benjamin; Kilbaugh, Todd J; Naim, Maryam Y; Wolfe, Heather; Bratinov, George; Shoap, Wesley; Hsieh, Ting-Chang; Nadkarni, Vinay M; Berg, Robert A; Sutton, Robert M

    2016-07-01

    The American Heart Association (AHA) recommends monitoring invasive arterial diastolic blood pressure (DBP) and end-tidal carbon dioxide (ETCO2) during cardiopulmonary resuscitation (CPR) when available. In intensive care unit patients, both may be available to the rescuer. The objective of this study was to compare DBP vs. ETCO2 during CPR as predictors of cardiac arrest survival. In two models of cardiac arrest (primary ventricular fibrillation [VF] and asphyxia-associated VF), 3-month old swine received either standard AHA guideline-based CPR or patient-centric, BP-guided CPR. Mean values of DBP and ETCO2 in the final 2min before the first defibrillation attempt were compared using receiver operating characteristic curves (area under curve [AUC] analysis). The optimal DBP cut point to predict survival was derived and subsequently validated in two independent, randomly generated cohorts. Of 60 animals, 37 (61.7%) survived to 45min. DBP was higher in survivors than in non-survivors (40.6±1.8mmHg vs. 25.9±2.4mmHg; p<0.001), while ETCO2 was not different (30.0±1.5mmHg vs. 32.5±1.8mmHg; p=0.30). By AUC analysis, DBP was superior to ETCO2 (0.82 vs. 0.60; p=0.025) in discriminating survivors from non-survivors. The optimal DBP cut point in the derivation cohort was 34.1mmHg. In the validation cohort, this cut point demonstrated a sensitivity of 0.78, specificity of 0.81, positive predictive value of 0.64, and negative predictive value of 0.89 for survival. In both primary and asphyxia-associated VF porcine models of cardiac arrest, DBP discriminates survivors from non-survivors better than ETCO2. Failure to attain a DBP >34mmHg during CPR is highly predictive of non-survival. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. A Quantitative Comparison of Physiologic Indicators of Cardiopulmonary Resuscitation Quality: Diastolic Blood Pressure Versus End-Tidal Carbon Dioxide

    PubMed Central

    Morgan, Ryan W.; French, Benjamin; Kilbaugh, Todd J.; Naim, Maryam Y.; Wolfe, Heather; Bratinov, George; Shoap, Wesley; Hsieh, Ting-Chang; Nadkarni, Vinay M.; Berg, Robert A.; Sutton, Robert M.

    2016-01-01

    Aim The American Heart Association (AHA) recommends monitoring invasive arterial diastolic blood pressure (DBP) and end-tidal carbon dioxide (ETCO2) during cardiopulmonary resuscitation (CPR) when available. In intensive care unit patients, both may be available to the rescuer. The objective of this study was to compare DBP versus ETCO2 during CPR as predictors of cardiac arrest survival. Methods In two models of cardiac arrest (primary ventricular fibrillation [VF] and asphyxia-associated VF), 3-month old swine received either standard AHA guideline-based CPR or patient-centric, BP-guided CPR. Mean values of DBP and ETCO2 in the final two minutes before the first defibrillation attempt were compared using receiver operating characteristic curves (area under curve [AUC] analysis). The optimal DBP cut point to predict survival was derived and subsequently validated in two independent, randomly generated cohorts. Results Of 60 animals, 37 (61.7%) survived to 45 minutes. DBP was higher in survivors than in non-survivors (40.6±1.8mmHg vs. 25.9±2.4mmHg; p<0.001), while ETCO2 was not different (30.0±1.5mmHg vs. 32.5±1.8mmHg; p=0.30). By AUC analysis, DBP was superior to ETCO2 (0.82 vs. 0.60; p=0.025) in discriminating survivors from non-survivors. The optimal DBP cut point in the derivation cohort was 34.1mmHg. In the validation cohort, this cut point demonstrated a sensitivity of 0.78, specificity of 0.81, positive predictive value of 0.64, and negative predictive value of 0.89 for survival. Conclusions In both primary and asphyxia-associated VF porcine models of cardiac arrest, DBP discriminates survivors from non-survivors better than ETCO2. Failure to attain a DBP >34mmHg during CPR is highly predictive of non-survival. PMID:27107688

  13. Atrial Electrogram Fractionation Distribution before and after Pulmonary Vein Isolation in Human Persistent Atrial Fibrillation-A Retrospective Multivariate Statistical Analysis.

    PubMed

    Almeida, Tiago P; Chu, Gavin S; Li, Xin; Dastagir, Nawshin; Tuan, Jiun H; Stafford, Peter J; Schlindwein, Fernando S; Ng, G André

    2017-01-01

    Purpose: Complex fractionated atrial electrograms (CFAE)-guided ablation after pulmonary vein isolation (PVI) has been used for persistent atrial fibrillation (persAF) therapy. This strategy has shown suboptimal outcomes due to, among other factors, undetected changes in the atrial tissue following PVI. In the present work, we investigate CFAE distribution before and after PVI in patients with persAF using a multivariate statistical model. Methods: 207 pairs of atrial electrograms (AEGs) were collected before and after PVI respectively, from corresponding LA regions in 18 persAF patients. Twelve attributes were measured from the AEGs, before and after PVI. Statistical models based on multivariate analysis of variance (MANOVA) and linear discriminant analysis (LDA) have been used to characterize the atrial regions and AEGs. Results: PVI significantly reduced CFAEs in the LA (70 vs. 40%; P < 0.0001). Four types of LA regions were identified, based on the AEGs characteristics: (i) fractionated before PVI that remained fractionated after PVI (31% of the collected points); (ii) fractionated that converted to normal (39%); (iii) normal prior to PVI that became fractionated (9%) and; (iv) normal that remained normal (21%). Individually, the attributes failed to distinguish these LA regions, but multivariate statistical models were effective in their discrimination ( P < 0.0001). Conclusion: Our results have unveiled that there are LA regions resistant to PVI, while others are affected by it. Although, traditional methods were unable to identify these different regions, the proposed multivariate statistical model discriminated LA regions resistant to PVI from those affected by it without prior ablation information.

  14. FHWA Traffic Noise Model, version 1.0 technical manual

    DOT National Transportation Integrated Search

    1998-02-01

    This Technical Manual is for the Federal Highway Administrations Traffic Noise Model (FHWA TNM), Version 1.0 -- the FHWAs computer program for highway traffic noise prediction and analysis. Two companion reports, a Users Guide and a data r...

  15. Simulated annealing model of acupuncture

    NASA Astrophysics Data System (ADS)

    Shang, Charles; Szu, Harold

    2015-05-01

    The growth control singularity model suggests that acupuncture points (acupoints) originate from organizers in embryogenesis. Organizers are singular points in growth control. Acupuncture can cause perturbation of a system with effects similar to simulated annealing. In clinical trial, the goal of a treatment is to relieve certain disorder which corresponds to reaching certain local optimum in simulated annealing. The self-organizing effect of the system is limited and related to the person's general health and age. Perturbation at acupoints can lead a stronger local excitation (analogous to higher annealing temperature) compared to perturbation at non-singular points (placebo control points). Such difference diminishes as the number of perturbed points increases due to the wider distribution of the limited self-organizing activity. This model explains the following facts from systematic reviews of acupuncture trials: 1. Properly chosen single acupoint treatment for certain disorder can lead to highly repeatable efficacy above placebo 2. When multiple acupoints are used, the result can be highly repeatable if the patients are relatively healthy and young but are usually mixed if the patients are old, frail and have multiple disorders at the same time as the number of local optima or comorbidities increases. 3. As number of acupoints used increases, the efficacy difference between sham and real acupuncture often diminishes. It predicted that the efficacy of acupuncture is negatively correlated to the disease chronicity, severity and patient's age. This is the first biological - physical model of acupuncture which can predict and guide clinical acupuncture research.

  16. Students concept understanding of fluid static based on the types of teaching

    NASA Astrophysics Data System (ADS)

    Rahmawati, I. D.; Suparmi; Sunarno, W.

    2018-03-01

    This research aims to know the concept understanding of student are taught by guided inquiry based learning and conventional based learning. Subjects in this study are high school students as much as 2 classes and each class consists of 32 students, both classes are homogen. The data was collected by conceptual test in the multiple choice form with the students argumentation of the answer. The data analysis used is qualitative descriptive method. The results of the study showed that the average of class that was using guided inquiry based learning is 78.44 while the class with use conventional based learning is 65.16. Based on these data, the guided inquiry model is an effective learning model used to improve students concept understanding.

  17. Guiding the Musical Growth of Children, Fifth and Sixth Grades. A Curriculum Guide.

    ERIC Educational Resources Information Center

    Smith, Hazel A.; And Others

    This guide is designed to serve as a point of departure for classroom teachers and music teacher specialists as they plan for the musical growth of 5th and 6th graders. The guide is also intended to be a source for materials. Topics covered in the document include harmony; songs for special days and season; rhythmic movement; listening to music;…

  18. Logistic regression model can reduce unnecessary artificial liver support in hepatitis B virus-associated acute-on-chronic liver failure: decision curve analysis.

    PubMed

    Qin, Gang; Bian, Zhao-Lian; Shen, Yi; Zhang, Lei; Zhu, Xiao-Hong; Liu, Yan-Mei; Shao, Jian-Guo

    2016-06-04

    Several models have been proposed to predict the short-term outcome of acute-on-chronic liver failure (ACLF) after treatment. We aimed to determine whether better decisions for artificial liver support system (ALSS) treatment could be made with a model than without, through decision curve analysis (DCA). The medical profiles of a cohort of 232 patients with hepatitis B virus (HBV)-associated ACLF were retrospectively analyzed to explore the role of plasma prothrombin activity (PTA), model for end-stage liver disease (MELD) and logistic regression model (LRM) in identifying patients who could benefit from ALSS. The accuracy and reliability of PTA, MELD and LRM were evaluated with previously reported cutoffs. DCA was performed to evaluate the clinical role of these models in predicting the treatment outcome. With the cut-off value of 0.2, LRM had sensitivity of 92.6 %, specificity of 42.3 % and an area under the receiving operating characteristic curve (AUC) of 0.68, which showed superior discrimination over PTA and MELD. DCA revealed that the LRM-guided ALSS treatment was superior over other strategies including "treating all" and MELD-guided therapy, for the midrange threshold probabilities of 16 to 64 %. The use of LRM-guided ALSS treatment could increase both the accuracy and efficiency of this procedure, allowing the avoidance of unnecessary ALSS.

  19. Intervention Planning Using a Laser Navigation System for CT-Guided Interventions: A Phantom and Patient Study

    PubMed Central

    Lee, Clara; Bolck, Jan; Naguib, Nagy N.N.; Schulz, Boris; Eichler, Katrin; Aschenbach, Rene; Wichmann, Julian L.; Vogl, Thomas. J.; Zangos, Stephan

    2015-01-01

    Objective To investigate the accuracy, efficiency and radiation dose of a novel laser navigation system (LNS) compared to those of free-handed punctures on computed tomography (CT). Materials and Methods Sixty punctures were performed using a phantom body to compare accuracy, timely effort, and radiation dose of the conventional free-handed procedure to those of the LNS-guided method. An additional 20 LNS-guided interventions were performed on another phantom to confirm accuracy. Ten patients subsequently underwent LNS-guided punctures. Results The phantom 1-LNS group showed a target point accuracy of 4.0 ± 2.7 mm (freehand, 6.3 ± 3.6 mm; p = 0.008), entrance point accuracy of 0.8 ± 0.6 mm (freehand, 6.1 ± 4.7 mm), needle angulation accuracy of 1.3 ± 0.9° (freehand, 3.4 ± 3.1°; p < 0.001), intervention time of 7.03 ± 5.18 minutes (freehand, 8.38 ± 4.09 minutes; p = 0.006), and 4.2 ± 3.6 CT images (freehand, 7.9 ± 5.1; p < 0.001). These results show significant improvement in 60 punctures compared to freehand. The phantom 2-LNS group showed a target point accuracy of 3.6 ± 2.5 mm, entrance point accuracy of 1.4 ± 2.0 mm, needle angulation accuracy of 1.0 ± 1.2°, intervention time of 1.44 ± 0.22 minutes, and 3.4 ± 1.7 CT images. The LNS group achieved target point accuracy of 5.0 ± 1.2 mm, entrance point accuracy of 2.0 ± 1.5 mm, needle angulation accuracy of 1.5 ± 0.3°, intervention time of 12.08 ± 3.07 minutes, and used 5.7 ± 1.6 CT-images for the first experience with patients. Conclusion Laser navigation system improved accuracy, duration of intervention, and radiation dose of CT-guided interventions. PMID:26175571

  20. Influence of guidance concept in complete dentures on oral health related quality of life - Canine guidance vs. bilateral balanced occlusion.

    PubMed

    Schierz, Oliver; Reissmann, Daniel

    2016-10-01

    To compare the impact of canine guided vs. bilateral balanced occlusion on oral health related quality of life (OHRQoL) as a patient-reported outcome measure. In this randomized single-blind crossover trial, 19 patients have been provided with new complete dentures in the maxilla and mandible. OHRQoL was assessed using the 49-item Oral Health Impact Profile (OHIP-49) before the start of the prosthodontic treatment (B), 3 months after insertion of the new dentures (T1), and 3 months after rework into the alternative concept (T2). Multilevel mixed-effect linear regression models were computed to determine the effect provided by the new set of dentures and the specific impact of the occlusal concept on OHRQoL using summary scores of the OHIP-49 and of a 19-items subset specific for edentulous patients (OHIP-EDENT). At baseline, participants' OHRQoL was substantially impaired indicated by an average OHIP-49 score of 42.1 points and an OHIP-EDENT score of 21.1 points. The effect of provision of a new set of complete dentures was a statistically significant decrease of 8.3 points (OHIP-49) and 4.0 points (OHIP-EDENT), respectively, representing a clinically relevant improvement in OHRQoL. When wearing dentures with bilateral balanced occlusion, participants showed on average 1.6 points higher OHIP-49 scores and 0.9 points higher OHIP-EDENT scores compared to canine guided dentures. This effect of the occlusal concept was neither statistically nor clinically significant. Both investigated occlusal concepts for complete dentures were comparable in their effect on patients' perceptions with none being considerably superior in terms of OHRQoL. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  1. User's guide for RAM. Volume II. Data preparation and listings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turner, D.B.; Novak, J.H.

    1978-11-01

    The information presented in this user's guide is directed to air pollution scientists having an interest in applying air quality simulation models. RAM is a method of estimating short-term dispersion using the Gaussian steady-state model. These algorithms can be used for estimating air quality concentrations of relatively nonreactive pollutants for averaging times from an hour to a day from point and area sources. The algorithms are applicable for locations with level or gently rolling terrain where a single wind vector for each hour is a good approximation to the flow over the source area considered. Calculations are performed for eachmore » hour. Hourly meteorological data required are wind direction, wind speed, temperature, stability class, and mixing height. Emission information required of point sources consists of source coordinates, emission rate, physical height, stack diameter, stack gas exit velocity, and stack gas temperature. Emission information required of area sources consists of southwest corner coordinates, source side length, total area emission rate and effective area source-height. Computation time is kept to a minimum by the manner in which concentrations from area sources are estimated using a narrow plume hypothesis and using the area source squares as given rather than breaking down all sources into an area of uniform elements. Options are available to the user to allow use of three different types of receptor locations: (1) those whose coordinates are input by the user, (2) those whose coordinates are determined by the model and are downwind of significant point and area sources where maxima are likely to occur, and (3) those whose coordinates are determined by the model to give good area coverage of a specific portion of the region. Computation time is also decreased by keeping the number of receptors to a minimum. Volume II presents RAM example outputs, typical run streams, variable glossaries, and Fortran source codes.« less

  2. Utility of Risk Models in Decision Making After Radical Prostatectomy: Lessons from a Natural History Cohort of Intermediate- and High-Risk Men.

    PubMed

    Ross, Ashley E; Yousefi, Kasra; Davicioni, Elai; Ghadessi, Mercedeh; Johnson, Michael H; Sundi, Debasish; Tosoian, Jeffery J; Han, Misop; Humphreys, Elizabeth B; Partin, Alan W; Walsh, Patrick C; Trock, Bruce J; Schaeffer, Edward M

    2016-03-01

    Current guidelines suggest adjuvant radiation therapy for men with adverse pathologic features (APFs) at radical prostatectomy (RP). We examine at-risk men treated only with RP until the time of metastasis. To evaluate whether clinicopathologic risk models can help guide postoperative therapeutic decision making. Men with National Comprehensive Cancer Network intermediate- or high-risk localized prostate cancer undergoing RP in the prostate-specific antigen (PSA) era were identified (n=3089). Only men with initial undetectable PSA after surgery and who received no therapy prior to metastasis were included. APFs were defined as pT3 disease or positive surgical margins. Area under the receiver operating characteristic curve (AUC) for time to event data was used to measure the discrimination performance of the risk factors. Cumulative incidence curves were constructed using Fine and Gray competing risks analysis to estimate the risk of biochemical recurrence (BCR) or metastasis, taking censoring and death due to other causes into consideration. Overall, 43% of the cohort (n=1327) had APFs at RP. Median follow-up for censored patients was 5 yr. Cumulative incidence of metastasis was 6% at 10 yr after RP for all patients. Cumulative incidence of metastasis among men with APFs was 7.5% at 10 yr after RP. Among men with BCR, the incidence of metastasis was 38% 5 yr after BCR. At 10 yr after RP, time-dependent AUC for predicting metastasis by Cancer of the Prostate Risk Assessment Postsurgical or Eggener risk models was 0.81 (95% confidence interval [CI], 0.72-0.97) and 0.78 (95% CI, 0.67-0.97) in the APF population, respectively. At 5 yr after BCR, these values were lower (0.58 [95% CI, 0.50-0.66] and 0.70 [95% CI, 0.63-0.76]) among those who developed BCR. Use of risk model cut points could substantially reduce overtreatment while minimally increasing undertreatment (ie, use of an Eggener cut point of 2.5% for treatment of men with APFs would spare 46% from treatment while only allowing for metastatic events in 1% at 10 yr after RP). Use of risk models reduces overtreatment and should be a routine part of patient counseling when considering adjuvant therapy. Risk model performance is significantly reduced among men with BCR. Use of current risk models can help guide decision making regarding therapy after surgery and reduce overtreatment. Copyright © 2015 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  3. NASA Hybrid Reflectometer Project

    NASA Technical Reports Server (NTRS)

    Lynch, Dana; Mancini, Ron (Technical Monitor)

    2002-01-01

    Time-domain and frequency-domain reflectometry have been used for about forty years to locate opens and shorts in cables. Interpretation of reflectometry data is as much art as science. Is there information in the data that is being missed? Can the reflectometers be improved to allow us to detect and locate defects in cables that are not outright shorts or opens? The Hybrid Reflectometer Project was begun this year at NASA Ames Research Center, initially to model wire physics, simulating time-domain reflectometry (TDR) signals in those models and validating the models against actual TDR data taken on testbed cables. Theoretical models of reflectometry in wires will give us an understanding of the merits and limits of these techniques and will guide the application of a proposed hybrid reflectometer with the aim of enhancing reflectometer sensitivity to the point that wire defects can be detected. We will point out efforts by some other researchers to apply wire physics models to the problem of defect detection in wires and we will describe our own initial efforts to create wire physics models and report on testbed validation of the TDR simulations.

  4. Ductile-Phase-Toughened Tungsten for Plasma-Facing Materials

    NASA Astrophysics Data System (ADS)

    Cunningham, Kevin Hawkins

    A variety of processing approaches were employed to fabricate ductile-phase-toughened (DPT) tungsten (W) composites. Mechanical testing and analytical modeling were used to guide composite development. This work provides a basis for further development of W composites to be used in structural divertor components of future fusion reactors. W wire was tested in tension, showing significant ductility and strength. Coatings of copper (Cu) or tungsten carbide (WC) were applied to the W wire via electrodeposition and carburization, respectively. Composites were fabricated using spark plasma sintering (SPS) to consolidate W powders together with each type of coated W wire. DPT behavior, e.g. crack arrest and crack bridging, was not observed in three-point bend testing of the sintered composites. A laminate was fabricated by hot pressing W and Cu foils together with W wires, and subsequently tested in tension. This laminate was bonded via hot pressing to thick W plate as a reinforcing layer, and the composite was tested in three-point bending. Crack arrest was observed along with some fiber pullout, but significant transverse cracking in the W plate confounded further fracture toughness analysis. The fracture toughness of thin W plate was measured in three-point bending. W plates were brazed with Cu foils to form a laminate. Crack arrest and crack bridging were observed in three-point bend tests of the laminate, and fracture resistance curves were successfully calculated for this DPT composite. An analytical model of crack bridging was developed using the basis described by Chao in previous work by the group. The model uses the specimen geometry, matrix properties, and the stress-displacement function of a ductile reinforcement ("bridging law") to calculate the fracture resistance curve (R-curve) and load-displacement curve (P-D curve) for any test specimen geometry. The code was also implemented to estimate the bridging law of an arbitrary composite using R-curve data. Finally, a parametric study was performed to quantitatively determine the necessary mechanical properties of useful toughening reinforcements for a DPT W composite. The analytical model has a broad applicability for any DPT material.

  5. PowerPoint Workshop for Teachers[TM].

    ERIC Educational Resources Information Center

    Caughlin, Janet

    This guide for teachers to the Microsoft PowerPoint multimedia presentation program begins with a section that introduces what PowerPoint is and why teachers should use it, Windows 95/98 basics, Macintosh basics, getting started, PowerPoint toolbars, and presentation tips. The next section discusses learning PowerPoint, including creating a…

  6. Accuracy of experimental mandibular osteotomy using the image-guided sagittal saw.

    PubMed

    Pietruski, P; Majak, M; Swiatek-Najwer, E; Popek, M; Szram, D; Zuk, M; Jaworowski, J

    2016-06-01

    The aim of this study was to perform an objective assessment of the accuracy of mandibular osteotomy simulations performed using an image-guided sagittal saw. A total of 16 image-guided mandibular osteotomies were performed on four prefabricated anatomical models according to the virtual plan. Postoperative computed tomography (CT) image data were fused with the preoperative CT scan allowing an objective comparison of the results of the osteotomy executed with the virtual plan. For each operation, the following parameters were analyzed and compared independently twice by two observers: resected bone volume, osteotomy trajectory angle, and marginal point positions. The mean target registration error was 0.95±0.19mm. For all osteotomies performed, the mean difference between the planned and actual bone resection volumes was 8.55±5.51%, the mean angular deviation between planned and actual osteotomy trajectory was 8.08±5.50°, and the mean difference between the preoperative and the postoperative marginal point positions was 2.63±1.27mm. In conclusion, despite the initial stages of the research, encouraging results were obtained. The current limitations of the navigated saw are discussed, as well as the improvements in technology that should increase its predictability and efficiency, making it a reliable method for improving the surgical outcomes of maxillofacial operations. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. TSARINA: User’s Guide to a Computer Model for Damage Assessment of Complex Airbase Targets.

    DTIC Science & Technology

    1980-07-01

    IF WITHIN RECTANGLE ENCLOSING PATTERN THAT IS PAPOLLTL TO 2018 . C AXES 2019. IF ((IT *L T . 1(1)).OR. (IT *GT. 1(3))) GO TO 3𔃻 2020. IF ((IT *LT. Y...1H /I¥/ 1H+ /,IS/ I- /,IE/ IN’ / 21)9. C THIS BOUTINE PLOTS THE IMPACT POINTS (BUT NOT CRATEPS) POE 2110. C ALL "ITS THAT HAVE BEEN STORED FOR A

  8. Atlas-guided volumetric diffuse optical tomography enhanced by generalized linear model analysis to image risk decision-making responses in young adults.

    PubMed

    Lin, Zi-Jing; Li, Lin; Cazzell, Mary; Liu, Hanli

    2014-08-01

    Diffuse optical tomography (DOT) is a variant of functional near infrared spectroscopy and has the capability of mapping or reconstructing three dimensional (3D) hemodynamic changes due to brain activity. Common methods used in DOT image analysis to define brain activation have limitations because the selection of activation period is relatively subjective. General linear model (GLM)-based analysis can overcome this limitation. In this study, we combine the atlas-guided 3D DOT image reconstruction with GLM-based analysis (i.e., voxel-wise GLM analysis) to investigate the brain activity that is associated with risk decision-making processes. Risk decision-making is an important cognitive process and thus is an essential topic in the field of neuroscience. The Balloon Analog Risk Task (BART) is a valid experimental model and has been commonly used to assess human risk-taking actions and tendencies while facing risks. We have used the BART paradigm with a blocked design to investigate brain activations in the prefrontal and frontal cortical areas during decision-making from 37 human participants (22 males and 15 females). Voxel-wise GLM analysis was performed after a human brain atlas template and a depth compensation algorithm were combined to form atlas-guided DOT images. In this work, we wish to demonstrate the excellence of using voxel-wise GLM analysis with DOT to image and study cognitive functions in response to risk decision-making. Results have shown significant hemodynamic changes in the dorsal lateral prefrontal cortex (DLPFC) during the active-choice mode and a different activation pattern between genders; these findings correlate well with published literature in functional magnetic resonance imaging (fMRI) and fNIRS studies. Copyright © 2014 The Authors. Human Brain Mapping Published by Wiley Periodicals, Inc.

  9. Visual cues for the retrieval of landmark memories by navigating wood ants.

    PubMed

    Harris, Robert A; Graham, Paul; Collett, Thomas S

    2007-01-23

    Even on short routes, ants can be guided by multiple visual memories. We investigate here the cues controlling memory retrieval as wood ants approach a one- or two-edged landmark to collect sucrose at a point along its base. In such tasks, ants store the desired retinal position of landmark edges at several points along their route. They guide subsequent trips by retrieving the appropriate memory and moving to bring the edges in the scene toward the stored positions. The apparent width of the landmark turns out to be a powerful cue for retrieving the desired retinal position of a landmark edge. Two other potential cues, the landmark's apparent height and the distance that the ant walks, have little effect on memory retrieval. A simple model encapsulates these conclusions and reproduces the ants' routes in several conditions. According to this model, the ant stores a look-up table. Each entry contains the apparent width of the landmark and the desired retinal position of vertical edges. The currently perceived width provides an index for retrieving the associated stored edge positions. The model accounts for the population behavior of ants and the idiosyncratic training routes of individual ants. Our results imply binding between the edge of a shape and its width and, further, imply that assessing the width of a shape does not depend on the presence of any particular local feature, such as a landmark edge. This property makes the ant's retrieval and guidance system relatively robust to edge occlusions.

  10. User's Guide for the Commercial Modular Aero-Propulsion System Simulation (C-MAPSS): Version 2

    NASA Technical Reports Server (NTRS)

    Liu, Yuan; Frederick, Dean K.; DeCastro, Jonathan A.; Litt, Jonathan S.; Chan, William W.

    2012-01-01

    This report is a Users Guide for version 2 of the NASA-developed Commercial Modular Aero-Propulsion System Simulation (C-MAPSS) software, which is a transient simulation of a large commercial turbofan engine (up to 90,000-lb thrust) with a realistic engine control system. The software supports easy access to health, control, and engine parameters through a graphical user interface (GUI). C-MAPSS v.2 has some enhancements over the original, including three actuators rather than one, the addition of actuator and sensor dynamics, and an improved controller, while retaining or improving on the convenience and user-friendliness of the original. C-MAPSS v.2 provides the user with a graphical turbofan engine simulation environment in which advanced algorithms can be implemented and tested. C-MAPSS can run user-specified transient simulations, and it can generate state-space linear models of the nonlinear engine model at an operating point. The code has a number of GUI screens that allow point-and-click operation, and have editable fields for user-specified input. The software includes an atmospheric model which allows simulation of engine operation at altitudes from sea level to 40,000 ft, Mach numbers from 0 to 0.90, and ambient temperatures from -60 to 103 F. The package also includes a power-management system that allows the engine to be operated over a wide range of thrust levels throughout the full range of flight conditions.

  11. CT Bronchus Sign and the Diagnostic Yield of Guided Bronchoscopy for Peripheral Pulmonary Lesions: A Systematic Review and Meta-Analysis.

    PubMed

    Ali, Muhammad S; Sethi, Jaskaran; Taneja, Amit; Musani, Ali; Maldonado, Fabien

    2018-06-07

    Indeterminate peripheral pulmonary lesions often require tissue diagnosis. If non-surgical biopsy techniques are considered, deciding between bronchoscopic transbronchial vs. CT guided transthoracic biopsy can be difficult. The former has a low diagnostic yield with a low complication risk, while the latter has a better diagnostic yield but a higher complication rate. Investigators have looked at various lesion characteristics that can predict the diagnostic yield of guided bronchoscopic biopsies. While consensus exists that larger size and proximity to the hilum increase the diagnostic yield, there is ongoing debate about the association between CT bronchus sign (air-filled bronchus in close proximity of the lesion as seen on CT) and the diagnostic yield of guided bronchoscopic modalities. To perform a meta-analysis and systematic review, determining the association between CT bronchus sign and the diagnostic yield of guided bronchoscopy for peripheral pulmonary lesions. MEDLINE, Embase, Scopus and Google Scholar were searched in January 2018 for guided bronchoscopy studies that had assessed the impact of CT bronchus sign on the diagnostic yield. The quality of included studies was assessed using Quality Assessment, Data Abstraction and Synthesis-2 tool. Meta-analysis was performed using MedCalc (version 18). Odds ratios were used to compare yield of lesions with and without bronchus sign. Random effects model was used when significant heterogeneity was observed (I2>40%). For 2199 lesions with CT bronchus sign, the overall weighted diagnostic yield was 74.1% (95% CI: 68.3-79.5%). For 971 lesions without CT bronchus sign, the overall weighted diagnostic yield was 49.6% (95% CI: 39.6-59.5%). The odds ratio for successfully diagnosing a lesion with CT bronchus was 3.4 (95% CI: 2.4-5.0). Possible sources of heterogeneity in the meta-analysis included differences in study designs, guidance modalities and cancer prevalence. The odds ratio for successfully diagnosing a lesion with CT bronchus sign was relatively lower for prospective studies. Peripheral pulmonary lesions with CT bronchus sign are more likely to be diagnosed with guided bronchoscopy as compared to the lesions without CT bronchus sign. Clinicians should consider this along with the lesion size and distance from hilum, when contemplating guided bronchoscopy for peripheral pulmonary lesions. To perform a meta-analysis and systematic review, determining the impact of CT bronchus sign on the diagnostic yield of guided bronchoscopy for peripheral pulmonary lesions. MEDLINE, Embase, Scopus and Google Scholar were searched in January 2018 for guided bronchoscopy studies that had assessed the impact of CT bronchus sign on the diagnostic yield. The quality of included studies was assessed using Quality Assessment, Data Abstraction and Synthesis-2 tool. Meta-analysis was performed using MedCalc (version 18). Odds ratios were used to compare yield of lesions with and without bronchus sign. Random effects model was used when significant heterogeneity was observed (I2>40%). For 2199 lesions with CT bronchus sign, the overall weighted diagnostic yield was 74.1% (95% CI: 68.3-79.5%). For 971 lesions without CT bronchus, the overall weighted diagnostic yield was 49.6% (95% CI: 39.6-59.5%). The odds ratio for successfully diagnosing a lesion with CT bronchus was 3.4 (95% CI: 2.4-5.0). I² index was 62.1 therefore random effects model was used. Peripheral pulmonary lesions with CT bronchus sign are much more likely to be successfully diagnosed with guided bronchoscopy as compared to the lesions without CT bronchus sign. Clinicians should consider the presence (or absence) of CT bronchus sign along with the size of the lesion and distance from the hilum, when contemplating guided bronchoscopic modalities for peripheral pulmonary lesions.

  12. Linked Sensitivity Analysis, Calibration, and Uncertainty Analysis Using a System Dynamics Model for Stroke Comparative Effectiveness Research.

    PubMed

    Tian, Yuan; Hassmiller Lich, Kristen; Osgood, Nathaniel D; Eom, Kirsten; Matchar, David B

    2016-11-01

    As health services researchers and decision makers tackle more difficult problems using simulation models, the number of parameters and the corresponding degree of uncertainty have increased. This often results in reduced confidence in such complex models to guide decision making. To demonstrate a systematic approach of linked sensitivity analysis, calibration, and uncertainty analysis to improve confidence in complex models. Four techniques were integrated and applied to a System Dynamics stroke model of US veterans, which was developed to inform systemwide intervention and research planning: Morris method (sensitivity analysis), multistart Powell hill-climbing algorithm and generalized likelihood uncertainty estimation (calibration), and Monte Carlo simulation (uncertainty analysis). Of 60 uncertain parameters, sensitivity analysis identified 29 needing calibration, 7 that did not need calibration but significantly influenced key stroke outcomes, and 24 not influential to calibration or stroke outcomes that were fixed at their best guess values. One thousand alternative well-calibrated baselines were obtained to reflect calibration uncertainty and brought into uncertainty analysis. The initial stroke incidence rate among veterans was identified as the most influential uncertain parameter, for which further data should be collected. That said, accounting for current uncertainty, the analysis of 15 distinct prevention and treatment interventions provided a robust conclusion that hypertension control for all veterans would yield the largest gain in quality-adjusted life years. For complex health care models, a mixed approach was applied to examine the uncertainty surrounding key stroke outcomes and the robustness of conclusions. We demonstrate that this rigorous approach can be practical and advocate for such analysis to promote understanding of the limits of certainty in applying models to current decisions and to guide future data collection. © The Author(s) 2016.

  13. Illicit use of prescription stimulants in a college student sample: a theory-guided analysis.

    PubMed

    Bavarian, Niloofar; Flay, Brian R; Ketcham, Patricia L; Smit, Ellen

    2013-10-01

    The illicit use of prescription stimulants (IUPS) has emerged as a high-risk behavior of the 21st century college student. As the study of IUPS is relatively new, we aimed to understand (1) characteristics of IUPS (i.e., initiation, administration routes, drug sources, motives, experiences), and (2) theory-guided intrapersonal, interpersonal, and environmental correlates associated with use. Using one-stage cluster sampling, 520 students (96.3% response rate) at one Pacific Northwest University completed a paper-based, in-classroom survey on IUPS behaviors and expected correlates. Aim 1 was addressed using descriptive statistics and aim 2 was addressed via three nested logistic regression analyses guided by the Theory of Triadic Influence. The prevalence of ever engaging in IUPS during college was 25.6%. The majority (>50.0%) of users reported initiation during college, oral use, friends as the drug source, academic motives, and experiencing desired outcomes. Intrapersonal correlates associated with use included identifying as White, lower grade point average, diagnoses of attention deficit disorder, and lower avoidance self-efficacy. Interpersonal correlates of use included off-campus residence, varsity sports participation, IUPS perceptions by socializing agents, and greater behavioral norms. Exposure to prescription drug print media, greater prescription stimulant knowledge, and positive attitudes towards prescription stimulants were environmental correlates associated with use. In all models, IUPS intentions were strongly associated with use. IUPS was prevalent on the campus under investigation and factors from the intrapersonal, interpersonal and environmental domains were associated with the behavior. Implications for prevention and future research are discussed. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. Illicit Use of Prescription Stimulants in a College Student Sample: A Theory-Guided Analysis*

    PubMed Central

    Bavarian, Niloofar; Flay, Brian R.; Ketcham, Patricia L.; Smit, Ellen

    2013-01-01

    Background The illicit use of prescription stimulants (IUPS) has emerged as a high-risk behavior of the 21st century college student. As the study of IUPS is relatively new, we aimed to understand 1) characteristics of IUPS (i.e., initiation, administration routes, drug sources, motives, experiences), and 2) theory-guided intrapersonal, interpersonal, and environmental correlates associated with use. Methods Using one-stage cluster sampling, 520 students (96.3% response rate) at one Pacific Northwest University completed a paper-based, in-classroom survey on IUPS behaviors and expected correlates. Aim 1 was addressed using descriptive statistics and aim 2 was addressed via three nested logistic regression analyses guided by the Theory of Triadic Influence. Results The prevalence of ever engaging in IUPS during college was 25.6%. The majority (>50.0%) of users reported initiation during college, oral use, friends as the drug source, academic motives, and experiencing desired outcomes. Intrapersonal correlates associated with use included identifying as White, lower grade point average, diagnoses of attention deficit disorder, and lower avoidance self-efficacy. Interpersonal correlates of use included off-campus residence, varsity sports participation, IUPS perceptions by socializing agents, and greater behavioral norms. Exposure to prescription drug print media, greater prescription stimulant knowledge, and positive attitudes towards prescription stimulants were environmental correlates associated with use. In all models, IUPS intentions were strongly associated with use. Conclusions IUPS was prevalent on the campus under investigation and factors from the intrapersonal, interpersonal and environmental domains were associated with the behavior. Implications for prevention and future research are discussed. PMID:23683794

  15. Users guide: The LaRC human-operator-simulator-based pilot model

    NASA Technical Reports Server (NTRS)

    Bogart, E. H.; Waller, M. C.

    1985-01-01

    A Human Operator Simulator (HOS) based pilot model has been developed for use at NASA LaRC for analysis of flight management problems. The model is currently configured to simulate piloted flight of an advanced transport airplane. The generic HOS operator and machine model was originally developed under U.S. Navy sponsorship by Analytics, Inc. and through a contract with LaRC was configured to represent a pilot flying a transport airplane. A version of the HOS program runs in batch mode on LaRC's (60-bit-word) central computer system. This document provides a guide for using the program and describes in some detail the assortment of files used during its operation.

  16. Real-Time MRI-Guided Endovascular Recanalization of Chronic Total Arterial Occlusion in a Swine Model

    PubMed Central

    Raval, Amish N.; Karmarkar, Parag V.; Guttman, Michael A.; Ozturk, Cengizhan; Sampath, Smita; DeSilva, Ranil; Aviles, Ronnier J.; Xu, Minnan; Wright, Victor J.; Schenke, William H.; Kocaturk, Ozgur; Dick, Alexander J.; Raman, Venkatesh K.; Atalar, Ergin; McVeigh, Elliot R.; Lederman, Robert J.

    2006-01-01

    Background Endovascular recanalization (guidewire traversal) of peripheral artery chronic total occlusion (CTO) can be challenging. X-Ray angiography resolves CTO poorly. Virtually “blind” device advancement during X-ray-guided interventions can lead to procedure failure, perforation and hemorrhage. Alternatively, magnetic resonance imaging (MRI) may delineate the artery within the occluded segment to enhance procedural safety and success. We hypothesized that real-time MRI (rtMRI) guided CTO recanalization can be accomplished in an animal model. Methods and Results Carotid artery CTO was created by balloon injury in 19 lipid overfed swine. After 6–8 weeks, two underwent direct necropsy analysis for histology, three underwent primary X-ray-guided CTO recanalization attempts, and the remaining 14 underwent rtMRI-guided recanalization attempts in a 1.5T interventional MRI system. rtMRI intervention used custom CTO catheters and guidewires that incorporated MRI receiver antennae to enhance device visibility. The mean length of the occluded segments was 13.3 ± 1.6cm. rtMRI-guided CTO recanalization was successful in 11/14 swine and only 1/3 swine using X-ray alone. After unsuccessful rtMRI (n = 3), X-ray-guided attempts also were all unsuccessful. Conclusions Recanalization of long CTO is feasible entirely using rtMRI guidance. Low profile clinical-grade devices will be required to translate this experience to humans. Endovascular recanalization of chronic total arterial occlusion (CTO) is challenging under conventional X-ray guidance because devices are advanced almost blindly. MRI can image CTO borders and luminal contents, and could potentially guide these procedures. We test the feasibility of real-time MRI guided wire traversal in a swine model of peripheral artery CTO using custom active MRI catheters. PMID:16490819

  17. Development of a Logic Model to Guide Evaluations of the ASCA National Model for School Counseling Programs

    ERIC Educational Resources Information Center

    Martin, Ian; Carey, John

    2014-01-01

    A logic model was developed based on an analysis of the 2012 American School Counselor Association (ASCA) National Model in order to provide direction for program evaluation initiatives. The logic model identified three outcomes (increased student achievement/gap reduction, increased school counseling program resources, and systemic change and…

  18. Business Modeling to Implement an eHealth Portal for Infection Control: A Reflection on Co-Creation With Stakeholders

    PubMed Central

    Wentzel, Jobke; Sanderman, Robbert; van Gemert-Pijnen, Lisette

    2015-01-01

    Background It is acknowledged that the success and uptake of eHealth improve with the involvement of users and stakeholders to make technology reflect their needs. Involving stakeholders in implementation research is thus a crucial element in developing eHealth technology. Business modeling is an approach to guide implementation research for eHealth. Stakeholders are involved in business modeling by identifying relevant stakeholders, conducting value co-creation dialogs, and co-creating a business model. Because implementation activities are often underestimated as a crucial step while developing eHealth, comprehensive and applicable approaches geared toward business modeling in eHealth are scarce. Objective This paper demonstrates the potential of several stakeholder-oriented analysis methods and their practical application was demonstrated using Infectionmanager as an example case. In this paper, we aim to demonstrate how business modeling, with the focus on stakeholder involvement, is used to co-create an eHealth implementation. Methods We divided business modeling in 4 main research steps. As part of stakeholder identification, we performed literature scans, expert recommendations, and snowball sampling (Step 1). For stakeholder analyzes, we performed “basic stakeholder analysis,” stakeholder salience, and ranking/analytic hierarchy process (Step 2). For value co-creation dialogs, we performed a process analysis and stakeholder interviews based on the business model canvas (Step 3). Finally, for business model generation, we combined all findings into the business model canvas (Step 4). Results Based on the applied methods, we synthesized a step-by-step guide for business modeling with stakeholder-oriented analysis methods that we consider suitable for implementing eHealth. Conclusions The step-by-step guide for business modeling with stakeholder involvement enables eHealth researchers to apply a systematic and multidisciplinary, co-creative approach for implementing eHealth. Business modeling becomes an active part in the entire development process of eHealth and starts an early focus on implementation, in which stakeholders help to co-create the basis necessary for a satisfying success and uptake of the eHealth technology. PMID:26272510

  19. FHWA Traffic Noise Model user's guide (version 2.0 addendum).

    DOT National Transportation Integrated Search

    2002-03-01

    In March 1998, the Federal Highway Administration (FHWA) Office of Natural : Environment, released the FHWA Traffic Noise Model (FHWA TNM) Version 1.0, a : state-of-the-art computer program for highway traffic noise prediction and : analysis. Since t...

  20. Electromagnetic dissipation during asymmetric reconnection with a moderate guide field

    NASA Astrophysics Data System (ADS)

    Genestreti, Kevin; Burch, James; Cassak, Paul; Torbert, Roy; Phan, Tai; Ergun, Robert; Giles, Barbara; Russell, Chris; Wang, Shan; Akhavan-Tafti, Mojtaba; Varsani, Ali

    2017-04-01

    We calculate the work done on the plasma by the electromagnetic (EM) field, ⃗Jṡ⃗E', and analyze the related electron currents and electric fields, focusing on a single asymmetric guide field electron diffusion region (EDR) event observed by MMS on 8 December 2015. For this event, each of the four MMS spacecraft observed dissipation of EM energy at the in-plane magnetic null point, though large-scale generation/dissipation was observed inconsistently on the magnetospheric side of the boundary. The current at the null was carried by a beam-like population of magnetosheath electrons traveling anti-parallel to the guide field, whereas the current on the Earthward side of the boundary was carried by crescent-shaped electron distributions. We also analyze the terms in Ohm's law, finding a large residual electric field throughout the EDR, inertial and pressure divergence fields at the null, and pressure divergence fields at the magnetosphere-side EDR. Our analysis of the terms in Ohm's law suggests that the EDR had significant three-dimensional structure.

  1. Renewable Energy Data Explorer User Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cox, Sarah L; Grue, Nicholas W; Tran, July

    This publication provides a user guide for the Renewable Energy Data Explorer and technical potential tool within the Explorer. The Renewable Energy Data Explorer is a dynamic, web-based geospatial analysis tool that facilitates renewable energy decision-making, investment, and deployment. It brings together renewable energy resource data and other modeled or measured geographic information system (GIS) layers, including land use, weather, environmental, population density, administrative, and grid data.

  2. Modeling of a Turbofan Engine with Ice Crystal Ingestion in the NASA Propulsion System Laboratory

    NASA Technical Reports Server (NTRS)

    Veres, Joseph P.; Jorgenson, Philip C. E.; Jones, Scott M.; Nili, Samaun

    2017-01-01

    The main focus of this study is to apply a computational tool for the flow analysis of the turbine engine that has been tested with ice crystal ingestion in the Propulsion Systems Laboratory (PSL) at NASA Glenn Research Center. The PSL has been used to test a highly instrumented Honeywell ALF502R-5A (LF11) turbofan engine at simulated altitude operating conditions. Test data analysis with an engine cycle code and a compressor flow code was conducted to determine the values of key icing parameters, that can indicate the risk of ice accretion, which can lead to engine rollback (un-commanded loss of engine thrust). The full engine aerothermodynamic performance was modeled with the Honeywell Customer Deck specifically created for the ALF502R-5A engine. The mean-line compressor flow analysis code, which includes a code that models the state of the ice crystal, was used to model the air flow through the fan-core and low pressure compressor. The results of the compressor flow analyses included calculations of the ice-water flow rate to air flow rate ratio (IWAR), the local static wet bulb temperature, and the particle melt ratio throughout the flow field. It was found that the assumed particle size had a large effect on the particle melt ratio, and on the local wet bulb temperature. In this study the particle size was varied parametrically to produce a non-zero calculated melt ratio in the exit guide vane (EGV) region of the low pressure compressor (LPC) for the data points that experienced a growth of blockage there, and a subsequent engine called rollback (CRB). At data points where the engine experienced a CRB having the lowest wet bulb temperature of 492 degrees Rankine at the EGV trailing edge, the smallest particle size that produced a non-zero melt ratio (between 3 percent - 4 percent) was on the order of 1 micron. This value of melt ratio was utilized as the target for all other subsequent data points analyzed, while the particle size was varied from 1 micron - 9.5 microns to achieve the target melt ratio. For data points that did not experience a CRB which had static wet bulb temperatures in the EGV region below 492 degrees Rankine, a non-zero melt ratio could not be achieved even with a 1 micron ice particle size. The highest value of static wet bulb temperature for data points that experienced engine CRB was 498 degrees Rankine with a particle size of 9.5 microns. Based on this study of the LF11 engine test data, the range of static wet bulb temperature at the EGV exit for engine CRB was in the narrow range of 492 degrees Rankine - 498 degrees Rankine , while the minimum value of IWAR was 0.002. The rate of blockage growth due to ice accretion and boundary layer growth was estimated by scaling from a known blockage growth rate that was determined in a previous study. These results obtained from the LF11 engine analysis formed the basis of a unique “icing wedge.”

  3. The GRASP 3: Graphical Reliability Analysis Simulation Program. Version 3: A users' manual and modelling guide

    NASA Technical Reports Server (NTRS)

    Phillips, D. T.; Manseur, B.; Foster, J. W.

    1982-01-01

    Alternate definitions of system failure create complex analysis for which analytic solutions are available only for simple, special cases. The GRASP methodology is a computer simulation approach for solving all classes of problems in which both failure and repair events are modeled according to the probability laws of the individual components of the system.

  4. A time series modeling approach in risk appraisal of violent and sexual recidivism.

    PubMed

    Bani-Yaghoub, Majid; Fedoroff, J Paul; Curry, Susan; Amundsen, David E

    2010-10-01

    For over half a century, various clinical and actuarial methods have been employed to assess the likelihood of violent recidivism. Yet there is a need for new methods that can improve the accuracy of recidivism predictions. This study proposes a new time series modeling approach that generates high levels of predictive accuracy over short and long periods of time. The proposed approach outperformed two widely used actuarial instruments (i.e., the Violence Risk Appraisal Guide and the Sex Offender Risk Appraisal Guide). Furthermore, analysis of temporal risk variations based on specific time series models can add valuable information into risk assessment and management of violent offenders.

  5. Office Occupations Curriculum Course Guide Postsecondary. Vocational Education, 1981.

    ERIC Educational Resources Information Center

    Aucoin, Margaret; And Others

    This publication is a curriculum guide for postsecondary office occupations education programs in Louisiana. The guide details courses to be taken in order for a student to major in the accounting, secretarial, or typist-clerk curriculum areas. Each of these three curriculum areas contains minimum requirements, exit points, hourly schedules, and…

  6. Exploration Guides as a Strategy to Improve the Effectiveness of Educational Software in Chemistry

    ERIC Educational Resources Information Center

    Paiva, Joao Carlos; da Costa, Luiza Alves

    2010-01-01

    Guiding students while they explore educational software is important in order to convey the pedagogical pragmatism that many programs seem to lack. This article points out some characteristics that we believe educational software exploration guides must contain for students to benefit from using these programs. The supporting information includes…

  7. Manatees: An Educator's Guide. Fourth Edition.

    ERIC Educational Resources Information Center

    Save the Manatee Club, Maitland, FL.

    The manatee is known for its gentleness and uniqueness and has become a symbol of human concern for endangered species. This guide provides current information on the West Indian manatee as well as strategies for teaching about this endangered animal. While focusing on the manatee, this guide points out the importance of interdependencies within…

  8. Mixing methodology, nursing theory and research design for a practice model of district nursing advocacy.

    PubMed

    Reed, Frances M; Fitzgerald, Les; Rae, Melanie

    2016-01-01

    To highlight philosophical and theoretical considerations for planning a mixed methods research design that can inform a practice model to guide rural district nursing end of life care. Conceptual models of nursing in the community are general and lack guidance for rural district nursing care. A combination of pragmatism and nurse agency theory can provide a framework for ethical considerations in mixed methods research in the private world of rural district end of life care. Reflection on experience gathered in a two-stage qualitative research phase, involving rural district nurses who use advocacy successfully, can inform a quantitative phase for testing and complementing the data. Ongoing data analysis and integration result in generalisable inferences to achieve the research objective. Mixed methods research that creatively combines philosophical and theoretical elements to guide design in the particular ethical situation of community end of life care can be used to explore an emerging field of interest and test the findings for evidence to guide quality nursing practice. Combining philosophy and nursing theory to guide mixed methods research design increases the opportunity for sound research outcomes that can inform a nursing model of care.

  9. An IBM-compatible program for interactive three-dimensional gravity modeling

    NASA Astrophysics Data System (ADS)

    Broome, John

    1992-04-01

    G3D is a 3-D interactive gravity modeling program for IBM-compatible microcomputers. The program allows a model to be created interactively by defining multiple tabular bodies with horizontal tops and bottoms. The resulting anomaly is calculated using Plouff's algorithm at up to 2000 predefined random or regularly located points. In order to display the anomaly as a color image, the point data are interpolated onto a regular grid and quantized into discrete intervals. Observed and residual gravity field images also can be generated. Adjustments to the model are made using a graphics cursor to move, insert, and delete body points or whole bodies. To facilitate model changes, planview body outlines can be overlain on any of the gravity field images during editing. The model's geometry can be displayed in planview or along a user-defined vertical section. G3D is written in Microsoft® FORTRAN and utilizes the Halo-Professional® (or Halo-88®) graphics subroutine library. The program is written for use on an IBM-compatible microcomputer equipped with hard disk, numeric coprocessor, and VGA, Number Nine Revolution (Halo-88® only), or TIGA® compatible graphics cards. A mouse or digitizing tablet is recommended for cursor positioning. Program source code, a user's guide, and sample data are available as Geological Survey of Canada Open File (G3D: A Three-dimensional Gravity Modeling Program for IBM-compatible Microcomputers).

  10. Dependence of the firearm-related homicide rate on gun availability: a mathematical analysis.

    PubMed

    Wodarz, Dominik; Komarova, Natalia L

    2013-01-01

    In the USA, the relationship between the legal availability of guns and the firearm-related homicide rate has been debated. It has been argued that unrestricted gun availability promotes the occurrence of firearm-induced homicides. It has also been pointed out that gun possession can protect potential victims when attacked. This paper provides a first mathematical analysis of this tradeoff, with the goal to steer the debate towards arguing about assumptions, statistics, and scientific methods. The model is based on a set of clearly defined assumptions, which are supported by available statistical data, and is formulated axiomatically such that results do not depend on arbitrary mathematical expressions. According to this framework, two alternative scenarios can minimize the gun-related homicide rate: a ban of private firearms possession, or a policy allowing the general population to carry guns. Importantly, the model identifies the crucial parameters that determine which policy minimizes the death rate, and thus serves as a guide for the design of future epidemiological studies. The parameters that need to be measured include the fraction of offenders that illegally possess a gun, the degree of protection provided by gun ownership, and the fraction of the population who take up their right to own a gun and carry it when attacked. Limited data available in the literature were used to demonstrate how the model can be parameterized, and this preliminary analysis suggests that a ban of private firearm possession, or possibly a partial reduction in gun availability, might lower the rate of firearm-induced homicides. This, however, should not be seen as a policy recommendation, due to the limited data available to inform and parameterize the model. However, the model clearly defines what needs to be measured, and provides a basis for a scientific discussion about assumptions and data.

  11. History as a guide to the future for cities: coastal storms and Jamaica Bay in New York City as an example.

    NASA Astrophysics Data System (ADS)

    Sanderson, E. W.; Orton, P. M.; Giampieri, M.; Spagnoli, C.

    2015-12-01

    History can provide a guide to the future by revealing the physical climatic and geomorphological dynamics with which cities must contend. We used historical maps from the U.S. Coast Survey and the Stevens Estuarine and Coastal Ocean Model (sECOM) to simulate how and where coastal flooding from storm surge affected the Jamaica Bay region of southeastern New York City at different points in time. This area, which houses approximately 1.2 million people today and the John F. Kennedy International Airport, was heavily impacted by coastal flooding during Hurricane Sandy. Historical analysis showed that the Rockaway Peninsula was an active barrier island system up until the early twentieth century, growing approximately 70 meters per year to the west between 1844 - 1891. Older historical maps made by American and European cartographers from 1524 - 1844 suggest that Jamaica Bay may have been a much more open system, with few or no interior marsh islands, at the time of European discovery. From these studies, we constructed digital terrain models and land cover maps for two historical periods: ca. 1870s and ca. 1609, and today. Storm simulations of hurricanes over the historical and present-day landscapes showed how a smaller inlet, shallower channel depths, and larger floodplains all can reduce the height of flooding inside the bay, and suggested a series of leverage experiments that test the efficacy of present-day green infrastructure interventions to lessen peak flood heights while maintaining tidal flushing. By combining history, modelling, and policy-relevant scenarios, we believe we have developed a reshreshing and accessible toolkit for policymakers thinking about resilience measures in coastal cities like New York.

  12. A Cost-Effectiveness Analysis of Blended Versus Face-to-Face Delivery of Evidence-Based Medicine to Medical Students

    PubMed Central

    Nicklen, Peter; Rivers, George; Foo, Jonathan; Ooi, Ying Ying; Reeves, Scott; Walsh, Kieran; Ilic, Dragan

    2015-01-01

    Background Blended learning describes a combination of teaching methods, often utilizing digital technologies. Research suggests that learner outcomes can be improved through some blended learning formats. However, the cost-effectiveness of delivering blended learning is unclear. Objective This study aimed to determine the cost-effectiveness of a face-to-face learning and blended learning approach for evidence-based medicine training within a medical program. Methods The economic evaluation was conducted as part of a randomized controlled trial (RCT) comparing the evidence-based medicine (EBM) competency of medical students who participated in two different modes of education delivery. In the traditional face-to-face method, students received ten 2-hour classes. In the blended learning approach, students received the same total face-to-face hours but with different activities and additional online and mobile learning. Online activities utilized YouTube and a library guide indexing electronic databases, guides, and books. Mobile learning involved self-directed interactions with patients in their regular clinical placements. The attribution and differentiation of costs between the interventions within the RCT was measured in conjunction with measured outcomes of effectiveness. An incremental cost-effectiveness ratio was calculated comparing the ongoing operation costs of each method with the level of EBM proficiency achieved. Present value analysis was used to calculate the break-even point considering the transition cost and the difference in ongoing operation cost. Results The incremental cost-effectiveness ratio indicated that it costs 24% less to educate a student to the same level of EBM competency via the blended learning approach used in the study, when excluding transition costs. The sunk cost of approximately AUD $40,000 to transition to the blended model exceeds any savings from using the approach within the first year of its implementation; however, a break-even point is achieved within its third iteration and relative savings in the subsequent years. The sensitivity analysis indicates that approaches with higher transition costs, or staffing requirements over that of a traditional method, are likely to result in negative value propositions. Conclusions Under the study conditions, a blended learning approach was more cost-effective to operate and resulted in improved value for the institution after the third year iteration, when compared to the traditional face-to-face model. The wider applicability of the findings are dependent on the type of blended learning utilized, staffing expertise, and educational context. PMID:26197801

  13. Water quality and non-point sources of risk: the Jiulong River Watershed, P. R. of China.

    PubMed

    Zhang, Jingjing; Zhang, Luoping; Ricci, Paolo F

    2012-01-01

    Retrospective water quality assessment plays an essential role in identifying trends and causal associations between exposures and risks, thus it can be a guide for water resources management. We have developed empirical relationships between several time-varying social and economic factors of economic development, water quality variables such as nitrate-nitrogen, COD(Mn), BOD(5), and DO, in the Jiulong River Watershed and its main tributary, the West River. Our analyses used alternative statistical methods to reduce the dimensionality of the analysis first and then strengthen the study's causal associations. The statistical methods included: factor analysis (FA), trend analysis, Monte Carlo/bootstrap simulations, robust regressions and a coupled equations model, integrated into a framework that allows an investigation and resolution of the issues that may affect the estimated results. After resolving these, we found that the concentrations of nitrogen compounds increased over time in the West River region, and that fertilizer used in agricultural fruit crops was the main risk with regard to nitrogen pollution. The relationships we developed can identify hazards and explain the impact of sources of different types of pollution, such as urbanization, and agriculture.

  14. The effect of inquiry-flipped classroom model toward students' achievement on chemical reaction rate

    NASA Astrophysics Data System (ADS)

    Paristiowati, Maria; Fitriani, Ella; Aldi, Nurul Hanifah

    2017-08-01

    The aim of this research is to find out the effect of Inquiry-Flipped Classroom Models toward Students' Achievement on Chemical Reaction Rate topic. This study was conducted at SMA Negeri 3 Tangerang in Eleventh Graders. The Quasi Experimental Method with Non-equivalent Control Group design was implemented in this study. 72 students as the sample was selected by purposive sampling. Students in experimental group were learned through inquiry-flipped classroom model. Meanwhile, in control group, students were learned through guided inquiry learning model. Based on the data analysis, it can be seen that there is significant difference in the result of the average achievement of the students. The average achievement of the students in inquiry-flipped classroom model was 83,44 and the average achievement of the students in guided inquiry learning model was 74,06. It can be concluded that the students' achievement with inquiry-flipped classroom better than guided inquiry. The difference of students' achievement were significant through t-test which is tobs 3.056 > ttable 1.994 (α = 0.005).

  15. Can integrative catchment management mitigate future water quality issues caused by climate change and socio-economic development?

    NASA Astrophysics Data System (ADS)

    Honti, Mark; Schuwirth, Nele; Rieckermann, Jörg; Stamm, Christian

    2017-03-01

    The design and evaluation of solutions for integrated surface water quality management requires an integrated modelling approach. Integrated models have to be comprehensive enough to cover the aspects relevant for management decisions, allowing for mapping of larger-scale processes such as climate change to the regional and local contexts. Besides this, models have to be sufficiently simple and fast to apply proper methods of uncertainty analysis, covering model structure deficits and error propagation through the chain of sub-models. Here, we present a new integrated catchment model satisfying both conditions. The conceptual iWaQa model was developed to support the integrated management of small streams. It can be used to predict traditional water quality parameters, such as nutrients and a wide set of organic micropollutants (plant and material protection products), by considering all major pollutant pathways in urban and agricultural environments. Due to its simplicity, the model allows for a full, propagative analysis of predictive uncertainty, including certain structural and input errors. The usefulness of the model is demonstrated by predicting future surface water quality in a small catchment with mixed land use in the Swiss Plateau. We consider climate change, population growth or decline, socio-economic development, and the implementation of management strategies to tackle urban and agricultural point and non-point sources of pollution. Our results indicate that input and model structure uncertainties are the most influential factors for certain water quality parameters. In these cases model uncertainty is already high for present conditions. Nevertheless, accounting for today's uncertainty makes management fairly robust to the foreseen range of potential changes in the next decades. The assessment of total predictive uncertainty allows for selecting management strategies that show small sensitivity to poorly known boundary conditions. The identification of important sources of uncertainty helps to guide future monitoring efforts and pinpoints key indicators, whose evolution should be closely followed to adapt management. The possible impact of climate change is clearly demonstrated by water quality substantially changing depending on single climate model chains. However, when all climate trajectories are combined, the human land use and management decisions have a larger influence on water quality against a time horizon of 2050 in the study.

  16. Automatic pole-like object modeling via 3D part-based analysis of point cloud

    NASA Astrophysics Data System (ADS)

    He, Liu; Yang, Haoxiang; Huang, Yuchun

    2016-10-01

    Pole-like objects, including trees, lampposts and traffic signs, are indispensable part of urban infrastructure. With the advance of vehicle-based laser scanning (VLS), massive point cloud of roadside urban areas becomes applied in 3D digital city modeling. Based on the property that different pole-like objects have various canopy parts and similar trunk parts, this paper proposed the 3D part-based shape analysis to robustly extract, identify and model the pole-like objects. The proposed method includes: 3D clustering and recognition of trunks, voxel growing and part-based 3D modeling. After preprocessing, the trunk center is identified as the point that has local density peak and the largest minimum inter-cluster distance. Starting from the trunk centers, the remaining points are iteratively clustered to the same centers of their nearest point with higher density. To eliminate the noisy points, cluster border is refined by trimming boundary outliers. Then, candidate trunks are extracted based on the clustering results in three orthogonal planes by shape analysis. Voxel growing obtains the completed pole-like objects regardless of overlaying. Finally, entire trunk, branch and crown part are analyzed to obtain seven feature parameters. These parameters are utilized to model three parts respectively and get signal part-assembled 3D model. The proposed method is tested using the VLS-based point cloud of Wuhan University, China. The point cloud includes many kinds of trees, lampposts and other pole-like posters under different occlusions and overlaying. Experimental results show that the proposed method can extract the exact attributes and model the roadside pole-like objects efficiently.

  17. ITS/operations resource guide 2007

    DOT National Transportation Integrated Search

    2007-01-01

    The U.S. Department of Transportations (U.S. DOTs) ITS/Operations Resource Guide 2007 is a comprehensive listing of over 400 documents, videos, websites, training courses, software tools, and points of contact related to intelligent transportat...

  18. Requirements' Role in Mobilizing and Enabling Design Conversation

    NASA Astrophysics Data System (ADS)

    Bergman, Mark

    Requirements play a critical role in a design conversation of systems and products. Product and system design exists at the crossroads of problems, solutions and requirements. Requirements contextualize problems and solutions, pointing the way to feasible outcomes. These are captured with models and detailed specifications. Still, stakeholders need to be able to understand one-another using shared design representations in order to mobilize bias and transform knowledge towards legitimized, desired results. Many modern modeling languages, including UML, as well as detailed, logic-based specifications are beyond the comprehension of key stakeholders. Hence, they inhibit, rather than promote design conversation. Improved design boundary objects (DBO), especially design requirements boundary objects (DRBO), need to be created and refined to improve the communications between principals. Four key features of design boundary objects that improve and promote design conversation are discussed in detail. A systems analysis and design case study is presented which demonstrates these features in action. It describes how a small team of analysts worked with key stakeholders to mobilize and guide a complex system design discussion towards an unexpected, yet desired outcome within a short time frame.

  19. The use of multi-dimensional flow and morphodynamic models for restoration design analysis

    NASA Astrophysics Data System (ADS)

    McDonald, R.; Nelson, J. M.

    2013-12-01

    River restoration projects with the goal of restoring a wide range of morphologic and ecologic channel processes and functions have become common. The complex interactions between flow and sediment-transport make it challenging to design river channels that are both self-sustaining and improve ecosystem function. The relative immaturity of the field of river restoration and shortcomings in existing methodologies for evaluating channel designs contribute to this problem, often leading to project failures. The call for increased monitoring of constructed channels to evaluate which restoration techniques do and do not work is ubiquitous and may lead to improved channel restoration projects. However, an alternative approach is to detect project flaws before the channels are built by using numerical models to simulate hydraulic and sediment-transport processes and habitat in the proposed channel (Restoration Design Analysis). Multi-dimensional models provide spatially distributed quantities throughout the project domain that may be used to quantitatively evaluate restoration designs for such important metrics as (1) the change in water-surface elevation which can affect the extent and duration of floodplain reconnection, (2) sediment-transport and morphologic change which can affect the channel stability and long-term maintenance of the design; and (3) habitat changes. These models also provide an efficient way to evaluate such quantities over a range of appropriate discharges including low-probability events which often prove the greatest risk to the long-term stability of restored channels. Currently there are many free and open-source modeling frameworks available for such analysis including iRIC, Delft3D, and TELEMAC. In this presentation we give examples of Restoration Design Analysis for each of the metrics above from projects on the Russian River, CA and the Kootenai River, ID. These examples demonstrate how detailed Restoration Design Analysis can be used to guide design elements and how this method can point out potential stability problems or other risks before designs proceed to the construction phase.

  20. The effect of guide-field and boundary conditions on collisionless magnetic reconnection in a stressed X-point collapse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Graf von der Pahlen, J.; Tsiklauri, D.

    2014-01-15

    Works of Tsiklauri and Haruki [Phys. Plasmas 15, 102902 (2008); 14, 112905 (2007)] are extended by inclusion of the out-of-plane magnetic (guide) field. In particular, magnetic reconnection during collisionless, stressed X-point collapse for varying out-of-plane guide-fields is studied using a kinetic, 2.5D, fully electromagnetic, relativistic particle-in-cell numerical code. For zero guide-field, cases for both open and closed boundary conditions are investigated, where magnetic flux and particles are lost and conserved, respectively. It is found that reconnection rates, out-of-plane currents and density in the X-point increase more rapidly and peak sooner in the closed boundary case, but higher values are reachedmore » in the open boundary case. The normalized reconnection rate is fast: 0.10-0.25. In the open boundary case it is shown that an increase of guide-field yields later onsets in the reconnection peak rates, while in the closed boundary case initial peak rates occur sooner but are suppressed. The reconnection current changes similarly with increasing guide-field; however for low guide-fields the reconnection current increases, giving an optimal value for the guide-field between 0.1 and 0.2 times the in-plane field in both cases. Also, in the open boundary case, it is found that for guide-fields of the order of the in-plane magnetic field, the generation of electron vortices occurs. Possible causes of the vortex generation, based on the flow of decoupled particles in the diffusion region and localized plasma heating, are discussed. Before peak reconnection onset, oscillations in the out-of-plane electric field at the X-point are found, ranging in frequency from approximately 1 to 2 ω{sub pe} and coinciding with oscillatory reconnection. These oscillations are found to be part of a larger wave pattern in the simulation domain. Mapping the out-of-plane electric field along the central lines of the domain over time and applying a 2D Fourier transform reveal that the waves predominantly correspond to the ordinary and the extraordinary mode and hence may correspond to observable radio waves such as solar radio burst fine structure spikes.« less

  1. Model competencies in regulatory therapeutic product assessment: Health Canada's good review guiding principles as a reviewing community's code of intellectual conduct.

    PubMed

    Lim, Robyn R

    2007-08-01

    This article describes some work from the Therapeutic Products Directorate of Health Canada regarding Good Review Practices (GRP). Background information is provided on the Therapeutic Products Directorate (TPD) and its regulatory activities regarding drug and medical device assessment in both the pre- and post-market setting. The TPD Good Review Guiding Principles (GRGP) are described which include a Definition of a Good Therapeutic Product Regulatory Review, Ten Hallmarks of a Good Therapeutic Product Regulatory Review and Ten Precepts. Analysis of the guiding principles discusses possible linkages between the guiding principles and intellectual virtues. Through this analysis an hypothesis is developed that the guiding principles outline a code of intellectual conduct for Health Canada's reviewers of evidence for efficacy, safety, manufacturing quality and benefit-risk regarding therapeutic products. Opportunities to advance therapeutic product regulatory review as a scientific discipline in its own right and to acknowledge that these reviewers constitute a specific community of practice are discussed. Integration of intellectual and ethical approaches across therapeutic product review sectors is also suggested.

  2. Bayesian modeling approach for characterizing groundwater arsenic contamination in the Mekong River basin.

    PubMed

    Cha, YoonKyung; Kim, Young Mo; Choi, Jae-Woo; Sthiannopkao, Suthipong; Cho, Kyung Hwa

    2016-01-01

    In the Mekong River basin, groundwater from tube-wells is a major drinking water source. However, arsenic (As) contamination in groundwater resources has become a critical issue in the watershed. In this study, As species such as total As (AsTOT), As(III), and As(V), were monitored across the watershed to investigate their characteristics and inter-relationships with water quality parameters, including pH and redox potential (Eh). The data illustrated a dramatic change in the relationship between AsTOT and Eh over a specific Eh range, suggesting the importance of Eh in predicting AsTOT. Thus, a Bayesian change-point model was developed to predict AsTOT concentrations based on Eh and pH, to determine changes in the AsTOT-Eh relationship. The model captured the Eh change-point (∼-100±15mV), which was compatible with the data. Importantly, the inclusion of this change-point in the model resulted in improved model fit and prediction accuracy; AsTOT concentrations were strongly negatively related to Eh values higher than the change-point. The process underlying this relationship was subsequently posited to be the reductive dissolution of mineral oxides and As release. Overall, AsTOT showed a weak positive relationship with Eh at a lower range, similar to those commonly observed in the Mekong River basin delta. It is expected that these results would serve as a guide for establishing public health strategies in the Mekong River Basin. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Parametrically Guided Generalized Additive Models with Application to Mergers and Acquisitions Data

    PubMed Central

    Fan, Jianqing; Maity, Arnab; Wang, Yihui; Wu, Yichao

    2012-01-01

    Generalized nonparametric additive models present a flexible way to evaluate the effects of several covariates on a general outcome of interest via a link function. In this modeling framework, one assumes that the effect of each of the covariates is nonparametric and additive. However, in practice, often there is prior information available about the shape of the regression functions, possibly from pilot studies or exploratory analysis. In this paper, we consider such situations and propose an estimation procedure where the prior information is used as a parametric guide to fit the additive model. Specifically, we first posit a parametric family for each of the regression functions using the prior information (parametric guides). After removing these parametric trends, we then estimate the remainder of the nonparametric functions using a nonparametric generalized additive model, and form the final estimates by adding back the parametric trend. We investigate the asymptotic properties of the estimates and show that when a good guide is chosen, the asymptotic variance of the estimates can be reduced significantly while keeping the asymptotic variance same as the unguided estimator. We observe the performance of our method via a simulation study and demonstrate our method by applying to a real data set on mergers and acquisitions. PMID:23645976

  4. Parametrically Guided Generalized Additive Models with Application to Mergers and Acquisitions Data.

    PubMed

    Fan, Jianqing; Maity, Arnab; Wang, Yihui; Wu, Yichao

    2013-01-01

    Generalized nonparametric additive models present a flexible way to evaluate the effects of several covariates on a general outcome of interest via a link function. In this modeling framework, one assumes that the effect of each of the covariates is nonparametric and additive. However, in practice, often there is prior information available about the shape of the regression functions, possibly from pilot studies or exploratory analysis. In this paper, we consider such situations and propose an estimation procedure where the prior information is used as a parametric guide to fit the additive model. Specifically, we first posit a parametric family for each of the regression functions using the prior information (parametric guides). After removing these parametric trends, we then estimate the remainder of the nonparametric functions using a nonparametric generalized additive model, and form the final estimates by adding back the parametric trend. We investigate the asymptotic properties of the estimates and show that when a good guide is chosen, the asymptotic variance of the estimates can be reduced significantly while keeping the asymptotic variance same as the unguided estimator. We observe the performance of our method via a simulation study and demonstrate our method by applying to a real data set on mergers and acquisitions.

  5. FHWA Traffic Noise Model version 1.1 user's guide (Addendum)

    DOT National Transportation Integrated Search

    2000-09-30

    In March 1998, the Federal Highway Administration (FHWA) Office of Natural Environment, released the FHWA Traffic Noise Model (FHWA TNM) Version 1.0, a state-of-the-art computer program for highway traffic noise prediction and analysis. Since then, t...

  6. Cost-Effectiveness Comparison of Imaging-Guided Prostate Biopsy Techniques: Systematic Transrectal Ultrasound, Direct In-Bore MRI, and Image Fusion.

    PubMed

    Venderink, Wulphert; Govers, Tim M; de Rooij, Maarten; Fütterer, Jurgen J; Sedelaar, J P Michiel

    2017-05-01

    Three commonly used prostate biopsy approaches are systematic transrectal ultrasound guided, direct in-bore MRI guided, and image fusion guided. The aim of this study was to calculate which strategy is most cost-effective. A decision tree and Markov model were developed to compare cost-effectiveness. Literature review and expert opinion were used as input. A strategy was deemed cost-effective if the costs of gaining one quality-adjusted life year (incremental cost-effectiveness ratio) did not exceed the willingness-to-pay threshold of €80,000 (≈$85,000 in January 2017). A base case analysis was performed to compare systematic transrectal ultrasound- and image fusion-guided biopsies. Because of a lack of appropriate literature regarding the accuracy of direct in-bore MRI-guided biopsy, a threshold analysis was performed. The incremental cost-effectiveness ratio for fusion-guided biopsy compared with systematic transrectal ultrasound-guided biopsy was €1386 ($1470) per quality-adjusted life year gained, which was below the willingness-to-pay threshold and thus assumed cost-effective. If MRI findings are normal in a patient with clinically significant prostate cancer, the sensitivity of direct in-bore MRI-guided biopsy has to be at least 88.8%. If that is the case, the incremental cost-effectiveness ratio is €80,000 per quality-adjusted life year gained and thus cost-effective. Fusion-guided biopsy seems to be cost-effective compared with systematic transrectal ultrasound-guided biopsy. Future research is needed to determine whether direct in-bore MRI-guided biopsy is the best pathway; in this study a threshold was calculated at which it would be cost-effective.

  7. Scan-To Output Validation: Towards a Standardized Geometric Quality Assessment of Building Information Models Based on Point Clouds

    NASA Astrophysics Data System (ADS)

    Bonduel, M.; Bassier, M.; Vergauwen, M.; Pauwels, P.; Klein, R.

    2017-11-01

    The use of Building Information Modeling (BIM) for existing buildings based on point clouds is increasing. Standardized geometric quality assessment of the BIMs is needed to make them more reliable and thus reusable for future users. First, available literature on the subject is studied. Next, an initial proposal for a standardized geometric quality assessment is presented. Finally, this method is tested and evaluated with a case study. The number of specifications on BIM relating to existing buildings is limited. The Levels of Accuracy (LOA) specification of the USIBD provides definitions and suggestions regarding geometric model accuracy, but lacks a standardized assessment method. A deviation analysis is found to be dependent on (1) the used mathematical model, (2) the density of the point clouds and (3) the order of comparison. Results of the analysis can be graphical and numerical. An analysis on macro (building) and micro (BIM object) scale is necessary. On macro scale, the complete model is compared to the original point cloud and vice versa to get an overview of the general model quality. The graphical results show occluded zones and non-modeled objects respectively. Colored point clouds are derived from this analysis and integrated in the BIM. On micro scale, the relevant surface parts are extracted per BIM object and compared to the complete point cloud. Occluded zones are extracted based on a maximum deviation. What remains is classified according to the LOA specification. The numerical results are integrated in the BIM with the use of object parameters.

  8. ACCESS 3. Approximation concepts code for efficient structural synthesis: User's guide

    NASA Technical Reports Server (NTRS)

    Fleury, C.; Schmit, L. A., Jr.

    1980-01-01

    A user's guide is presented for ACCESS-3, a research oriented program which combines dual methods and a collection of approximation concepts to achieve excellent efficiency in structural synthesis. The finite element method is used for structural analysis and dual algorithms of mathematical programming are applied in the design optimization procedure. This program retains all of the ACCESS-2 capabilities and the data preparation formats are fully compatible. Four distinct optimizer options were added: interior point penalty function method (NEWSUMT); second order primal projection method (PRIMAL2); second order Newton-type dual method (DUAL2); and first order gradient projection-type dual method (DUAL1). A pure discrete and mixed continuous-discrete design variable capability, and zero order approximation of the stress constraints are also included.

  9. Eukaryotic Chemotaxis

    PubMed Central

    Rappel, Wouter-Jan; Loomis, William F.

    2009-01-01

    During eukaryotic chemotaxis, external chemical gradients guide the crawling motion of cells. This process plays an important role in a large variety of biological systems and has wide ranging medical implications. New experimental techniques including confocal microscopy and microfluidics have advanced our understanding of chemotaxis while numerical modeling efforts are beginning to offer critical insights. In this short review, we survey the current experimental status of the field by dividing chemotaxis into three distinct “modules”: directional sensing, polarity and motility. For each module, we attempt to point out potential new directions of research and discuss how modeling studies interact with experimental investigations. PMID:20648241

  10. Kinematic Methods of Designing Free Form Shells

    NASA Astrophysics Data System (ADS)

    Korotkiy, V. A.; Khmarova, L. I.

    2017-11-01

    The geometrical shell model is formed in light of the set requirements expressed through surface parameters. The shell is modelled using the kinematic method according to which the shell is formed as a continuous one-parameter set of curves. The authors offer a kinematic method based on the use of second-order curves with a variable eccentricity as a form-making element. Additional guiding ruled surfaces are used to control the designed surface form. The authors made a software application enabling to plot a second-order curve specified by a random set of five coplanar points and tangents.

  11. DAC-3 Pointing Stability Analysis Results for SAGE 3 and Other Users of the International Space Station (ISS) Payload Attachment Sites (PAS)

    NASA Technical Reports Server (NTRS)

    Woods-Vedeler, Jessica A.; Rombado, Gabriel

    1997-01-01

    The purpose of this paper is to provide final results of a pointing stability analysis for external payload attachment sites (PAS) on the International Space Station (ISS). As a specific example, the pointing stability requirement of the SAGE III atmospheric science instrument was examined in this paper. The instrument requires 10 arcsec stability over 2 second periods. SAGE 3 will be mounted on the ISS starboard side at the lower, outboard FIAS. In this engineering analysis, an open-loop DAC-3 finite element model of ISS was used by the Microgravity Group at Johnson Space Flight Center to generate transient responses at PAS to a limited number of disturbances. The model included dynamics up to 50 Hz. Disturbance models considered included operation of the solar array rotary joints, thermal radiator rotary joints, and control moment gyros. Responses were filtered to model the anticipated vibration attenuation effects of active control systems on the solar and thermal radiator rotary joints. A pointing stability analysis was conducted by double integrating acceleration transient over a 2 second period. Results of the analysis are tabulated for ISS X, Y, and Z Axis rotations. These results indicate that the largest excursions in rotation during pointing occurred due to rapid slewing of the thermal radiator. Even without attenuation at the rotary joints, the resulting pointing error was limited to less than 1.6 arcsec. With vibration control at the joints, to a maximum 0.5 arcsec over a 2 second period. Based on this current level of model definition, it was concluded that between 0 - 50 Hz, the pointing stability requirement for SAGE 3 will not be exceeded by the disturbances evaluated in this study.

  12. Modeling of phase velocity and frequency spectrum of guided Lamb waves in piezoelectric-semiconductor multilayered structures made of AlAs and GaAs

    NASA Astrophysics Data System (ADS)

    Othmani, Cherif; Takali, Farid; Njeh, Anouar

    2017-11-01

    Modeling of guided Lamb waves propagation in piezoelectric-semiconductor multilayered structures made of AlAs and GaAs is evaluated in this paper. Here, the Legendre polynomial method is used to calculate dispersion curves, frequency spectrum and field distributions of guided Lamb waves propagation modes in AlAs, GaAs, AlAs/GaAs and AlAs/GaAs/AlAs-1/2/1 structures. In fact, formulations are given for open-circuit surface. Consequently, the polynomial method is numerically stable according to the total number of layers and the frequency range. This analysis is meaningful for the applications of the piezoelectric-semiconductor multilayered structures made of AlAs and GaAs such as in novel acoustic devices.

  13. TLS for generating multi-LOD of 3D building model

    NASA Astrophysics Data System (ADS)

    Akmalia, R.; Setan, H.; Majid, Z.; Suwardhi, D.; Chong, A.

    2014-02-01

    The popularity of Terrestrial Laser Scanners (TLS) to capture three dimensional (3D) objects has been used widely for various applications. Development in 3D models has also led people to visualize the environment in 3D. Visualization of objects in a city environment in 3D can be useful for many applications. However, different applications require different kind of 3D models. Since a building is an important object, CityGML has defined a standard for 3D building models at four different levels of detail (LOD). In this research, the advantages of TLS for capturing buildings and the modelling process of the point cloud can be explored. TLS will be used to capture all the building details to generate multi-LOD. This task, in previous works, involves usually the integration of several sensors. However, in this research, point cloud from TLS will be processed to generate the LOD3 model. LOD2 and LOD1 will then be generalized from the resulting LOD3 model. Result from this research is a guiding process to generate the multi-LOD of 3D building starting from LOD3 using TLS. Lastly, the visualization for multi-LOD model will also be shown.

  14. Dysphagia Management and Research in an Acute-Care Military Treatment Facility: The Role of Applied Informatics.

    PubMed

    Solomon, Nancy Pearl; Dietsch, Angela M; Dietrich-Burns, Katie E; Styrmisdottir, Edda L; Armao, Christopher S

    2016-05-01

    This report describes the development and preliminary analysis of a database for traumatically injured military service members with dysphagia. A multidimensional database was developed to capture clinical variables related to swallowing. Data were derived from clinical records and instrumental swallow studies, and ranged from demographics, injury characteristics, swallowing biomechanics, medications, and standardized tools (e.g., Glasgow Coma Scale, Penetration-Aspiration Scale). Bayesian Belief Network modeling was used to analyze the data at intermediate points, guide data collection, and predict outcomes. Predictive models were validated with independent data via receiver operating characteristic curves. The first iteration of the model (n = 48) revealed variables that could be collapsed for the second model (n = 96). The ability to predict recovery from dysphagia improved from the second to third models (area under the curve = 0.68 to 0.86). The third model, based on 161 cases, revealed "initial diet restrictions" as first-degree, and "Glasgow Coma Scale, intubation history, and diet change" as second-degree associates for diet restrictions at discharge. This project demonstrates the potential for bioinformatics to advance understanding of dysphagia. This database in concert with Bayesian Belief Network modeling makes it possible to explore predictive relationships between injuries and swallowing function, individual variability in recovery, and appropriate treatment options. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  15. CRISPR/Cas9 mediated genome editing in ES cells and its application for chimeric analysis in mice.

    PubMed

    Oji, Asami; Noda, Taichi; Fujihara, Yoshitaka; Miyata, Haruhiko; Kim, Yeon Joo; Muto, Masanaga; Nozawa, Kaori; Matsumura, Takafumi; Isotani, Ayako; Ikawa, Masahito

    2016-08-17

    Targeted gene disrupted mice can be efficiently generated by expressing a single guide RNA (sgRNA)/CAS9 complex in the zygote. However, the limited success of complicated genome editing, such as large deletions, point mutations, and knockins, remains to be improved. Further, the mosaicism in founder generations complicates the genotypic and phenotypic analyses in these animals. Here we show that large deletions with two sgRNAs as well as dsDNA-mediated point mutations are efficient in mouse embryonic stem cells (ESCs). The dsDNA-mediated gene knockins are also feasible in ESCs. Finally, we generated chimeric mice with biallelic mutant ESCs for a lethal gene, Dnajb13, and analyzed their phenotypes. Not only was the lethal phenotype of hydrocephalus suppressed, but we also found that Dnajb13 is required for sperm cilia formation. The combination of biallelic genome editing in ESCs and subsequent chimeric analysis provides a useful tool for rapid gene function analysis in the whole organism.

  16. Development and numerical analysis of low specific speed mixed-flow pump

    NASA Astrophysics Data System (ADS)

    Li, H. F.; Huo, Y. W.; Pan, Z. B.; Zhou, W. C.; He, M. H.

    2012-11-01

    With the development of the city, the market of the mixed flow pump with large flux and high head is prospect. The KSB Shanghai Pump Co., LTD decided to develop low speed specific speed mixed flow pump to meet the market requirements. Based on the centrifugal pump and axial flow pump model, aiming at the characteristics of large flux and high head, a new type of guide vane mixed flow pump was designed. The computational fluid dynamics method was adopted to analyze the internal flow of the new type model and predict its performances. The time-averaged Navier-Stokes equations were closed by SST k-ω turbulent model to adapt internal flow of guide vane with larger curvatures. The multi-reference frame(MRF) method was used to deal with the coupling of rotating impeller and static guide vane, and the SIMPLEC method was adopted to achieve the coupling solution of velocity and pressure. The computational results shows that there is great flow impact on the head of vanes at different working conditions, and there is great flow separation at the tailing of the guide vanes at different working conditions, and all will affect the performance of pump. Based on the computational results, optimizations were carried out to decrease the impact on the head of vanes and flow separation at the tailing of the guide vanes. The optimized model was simulated and its performance was predicted. The computational results show that the impact on the head of vanes and the separation at the tailing of the guide vanes disappeared. The high efficiency of the optimized pump is wide, and it fit the original design destination. The newly designed mixed flow pump is now in modeling and its experimental performance will be getting soon.

  17. Reducing duplex examinations in patients with iatrogenic pseudoaneurysms.

    PubMed

    Stone, Patrick A; Aburahma, Ali F; Flaherty, Sarah K

    2006-06-01

    Ultrasound-guided thrombin injection has become the initial treatment of choice for femoral access-related pseudoaneurysms. Patients typically undergo serial duplex examinations to assess for spontaneous resolution of small iatrogenic pseudoaneurysms (IPSAs) (<2.5 cm), or may require repeated diagnostic, therapeutic, and follow-up studies for larger IPSAs (>2.5 cm). We evaluated the impact of a revised treatment algorithm that includes primary treatment of both small (<2.5 cm) and larger pseudoaneurysms (>2.5 cm), rather than observation of smaller ones, and attempts to establish a single duplex examination via a point-of-care treatment strategy. We reviewed 105 consecutive patients treated with ultrasound-guided thrombin injection from July 2001 through September 2004. Patient, IPSAs, characteristics, and treatment methods were examined. The number of duplex examinations per patient was evaluated over the treatment interval. Also, published cost data were used to compare primary treatment of small ISPAs vs observation with serial duplex examinations. Successful thrombosis occurred in 103 (98.1%) of 105 treated pseudoaneurysms. No minor or major complications occurred after thrombin injection in either small or large ISPAs, and both failures requiring operation were in the large aneurysm group. The recurrence rate for the series was 1.9% (2/105), and both recurrences were successfully treated with an additional thrombin injection. A single injection was successful in treating 43 (97.7%) of 44 small (<2.5 cm) IPSAs, and one required a second injection. Patients had an average of 3.3 duplex examinations in our first year of treatment experience, which declined to 1.5 by our third year with the institution of a point-of-care service model for all pseudoaneurysms. Based on this decreased use of duplex examination and an average treatment cohort of 35 IPSA patients per year our institution, we determined this results in a reduction of 35 hours of laboratory time and nearly 70 ultrasounds per year. Similarly for small pseudoaneurysms, a point-of-service primary treatment program rather than observation results in an estimated cost savings of $12,000, based on treating 15 small IPSAs per year. Ultrasound-guided thrombin injection is safe and effective for the treatment of nearly all iatrogenic pseudoaneurysms. We recommend primary treatment of small pseudoaneurysms by ultrasound-guided thrombin injection rather than observation with serial duplex scans. A point-of-care treatment algorithm can result in cost savings by reducing the number of necessary duplex examinations.

  18. Localized Electron Heating by Strong Guide-Field Magnetic Reconnection

    NASA Astrophysics Data System (ADS)

    Guo, Xuehan; Sugawara, Takumichi; Inomoto, Michiaki; Yamasaki, Kotaro; Ono, Yasushi; UTST Team

    2015-11-01

    Localized electron heating of magnetic reconnection was studied under strong guide-field (typically Bt 15Bp) using two merging spherical tokamak plasmas in Univ. Tokyo Spherical Tokamak (UTST) experiment. Our new slide-type two-dimensional Thomson scattering system documented for the first time the electron heating localized around the X-point. The region of high electron temperature, which is perpendicular to the magnetic field, was found to have a round shape with radius of 2 [cm]. Also, it was localized around the X-point and does not agree with that of energy dissipation term Et .jt . When we include a guide-field effect term Bt / (Bp + αBt) for Et .jt where α =√{ (vin2 +vout2) /v∥2 } , the energy dissipation area becomes localized around the X-point, suggesting that the electrons are accelerated by the reconnection electric field parallel to the magnetic field and thermalized around the X-point. This work was supported by JSPS A3 Foresight Program ``Innovative Tokamak Plasma Startup and Current Drive in Spherical Torus,'' a Grant-in-Aid from the Japan Society for the Promotion of Science (JSPS) Fellows 15J03758.

  19. Downstream fish passage guide walls: A hydraulic scale model analysis

    USGS Publications Warehouse

    Mulligan, Kevin; Towler, Brett; Haro, Alexander J.; Ahlfeld, David P.

    2018-01-01

    Partial-depth guide walls are used to improve passage efficiency and reduce the delay of out-migrating anadromous fish species by guiding fish to a bypass route (i.e. weir, pipe, sluice gate) that circumvents the turbine intakes, where survival is usually lower. Evaluation and monitoring studies, however, indicate a high propensity for some fish to pass underneath, rather than along, the guide walls, compromising their effectiveness. In the present study we evaluated a range of guide wall structures to identify where/if the flow field shifts from sweeping (i.e. flow direction primarily along the wall and towards the bypass) to downward-dominant. Many migratory fish species, particularly juveniles, are known to drift with the flow and/or exhibit rheotactic behaviour during their migration. When these behaviours are present, fish follow the path of the flow field. Hence, maintaining a strong sweeping velocity in relation to the downward velocity along a guide wall is essential to successful fish guidance. Nine experiments were conducted to measure the three-dimensional velocity components upstream of a scale model guide wall set at a wide range of depths and angles to flow. Results demonstrated how each guide wall configuration affected the three-dimensional velocity components, and hence the downward and sweeping velocity, along the full length of the guide wall. In general, the velocities produced in the scale model were sweeping dominant near the water surface and either downward dominant or close to the transitional depth near the bottom of the guide wall. The primary exception to this shift from sweeping do downward flow was for the minimum guide wall angle tested in this study (15°). At 15° the flow pattern was fully sweeping dominant for every cross-section, indicating that a guide wall with a relatively small angle may be more likely to produce conditions favorable to efficient guidance. A critical next step is to evaluate the behaviour of migratory fish as they approach and swim along a guide wall in a controlled laboratory environment.

  20. Elementary Level Educational Curriculum Guide

    DOT National Transportation Integrated Search

    1989-01-01

    This guide contains current and accurate information about the agricultural aviation industry. The hands-on design or practical approach allows for and encourages flexibility. The designated grade levels serve only as a suggested entry point for inst...

  1. Exploratory Usability Testing of User Interface Options in LibGuides 2

    ERIC Educational Resources Information Center

    Thorngate, Sarah; Hoden, Allison

    2017-01-01

    Online research guides offer librarians a way to provide digital researchers with point-of-need support. If these guides are to support student learning well, it is critical that they provide an effective user experience. This article details the results of an exploratory comparison study that tested three key user interface options in LibGuides…

  2. Guide to International Academic Standards for Athletics Eligibility for Students Entering Fall 2007

    ERIC Educational Resources Information Center

    Mills, Lisa; Nguyen, Binh; Auten, Lisa

    2007-01-01

    The "NCAA Guide to International Academic Standards for Athletics Eligibility" provides specific criteria to be used as a guide in reviewing the initial eligibility (graduation, core curriculum, grade-point average and ACT/SAT test scores) of students who have completed any portion of their secondary education in a non-United States…

  3. Focus on Hinduism: Audio-Visual Resources for Teaching Religion. Occasional Publication No. 23.

    ERIC Educational Resources Information Center

    Dell, David; And Others

    The guide presents annotated lists of audio and visual materials about the Hindu religion. The authors point out that Hinduism cannot be comprehended totally by reading books; thus the resources identified in this guide will enhance understanding based on reading. The guide is intended for use by high school and college students, teachers,…

  4. DeepInfer: open-source deep learning deployment toolkit for image-guided therapy

    NASA Astrophysics Data System (ADS)

    Mehrtash, Alireza; Pesteie, Mehran; Hetherington, Jorden; Behringer, Peter A.; Kapur, Tina; Wells, William M.; Rohling, Robert; Fedorov, Andriy; Abolmaesumi, Purang

    2017-03-01

    Deep learning models have outperformed some of the previous state-of-the-art approaches in medical image analysis. Instead of using hand-engineered features, deep models attempt to automatically extract hierarchical representations at multiple levels of abstraction from the data. Therefore, deep models are usually considered to be more flexible and robust solutions for image analysis problems compared to conventional computer vision models. They have demonstrated significant improvements in computer-aided diagnosis and automatic medical image analysis applied to such tasks as image segmentation, classification and registration. However, deploying deep learning models often has a steep learning curve and requires detailed knowledge of various software packages. Thus, many deep models have not been integrated into the clinical research work ows causing a gap between the state-of-the-art machine learning in medical applications and evaluation in clinical research procedures. In this paper, we propose "DeepInfer" - an open-source toolkit for developing and deploying deep learning models within the 3D Slicer medical image analysis platform. Utilizing a repository of task-specific models, DeepInfer allows clinical researchers and biomedical engineers to deploy a trained model selected from the public registry, and apply it to new data without the need for software development or configuration. As two practical use cases, we demonstrate the application of DeepInfer in prostate segmentation for targeted MRI-guided biopsy and identification of the target plane in 3D ultrasound for spinal injections.

  5. DeepInfer: Open-Source Deep Learning Deployment Toolkit for Image-Guided Therapy.

    PubMed

    Mehrtash, Alireza; Pesteie, Mehran; Hetherington, Jorden; Behringer, Peter A; Kapur, Tina; Wells, William M; Rohling, Robert; Fedorov, Andriy; Abolmaesumi, Purang

    2017-02-11

    Deep learning models have outperformed some of the previous state-of-the-art approaches in medical image analysis. Instead of using hand-engineered features, deep models attempt to automatically extract hierarchical representations at multiple levels of abstraction from the data. Therefore, deep models are usually considered to be more flexible and robust solutions for image analysis problems compared to conventional computer vision models. They have demonstrated significant improvements in computer-aided diagnosis and automatic medical image analysis applied to such tasks as image segmentation, classification and registration. However, deploying deep learning models often has a steep learning curve and requires detailed knowledge of various software packages. Thus, many deep models have not been integrated into the clinical research workflows causing a gap between the state-of-the-art machine learning in medical applications and evaluation in clinical research procedures. In this paper, we propose "DeepInfer" - an open-source toolkit for developing and deploying deep learning models within the 3D Slicer medical image analysis platform. Utilizing a repository of task-specific models, DeepInfer allows clinical researchers and biomedical engineers to deploy a trained model selected from the public registry, and apply it to new data without the need for software development or configuration. As two practical use cases, we demonstrate the application of DeepInfer in prostate segmentation for targeted MRI-guided biopsy and identification of the target plane in 3D ultrasound for spinal injections.

  6. DeepInfer: Open-Source Deep Learning Deployment Toolkit for Image-Guided Therapy

    PubMed Central

    Mehrtash, Alireza; Pesteie, Mehran; Hetherington, Jorden; Behringer, Peter A.; Kapur, Tina; Wells, William M.; Rohling, Robert; Fedorov, Andriy; Abolmaesumi, Purang

    2017-01-01

    Deep learning models have outperformed some of the previous state-of-the-art approaches in medical image analysis. Instead of using hand-engineered features, deep models attempt to automatically extract hierarchical representations at multiple levels of abstraction from the data. Therefore, deep models are usually considered to be more flexible and robust solutions for image analysis problems compared to conventional computer vision models. They have demonstrated significant improvements in computer-aided diagnosis and automatic medical image analysis applied to such tasks as image segmentation, classification and registration. However, deploying deep learning models often has a steep learning curve and requires detailed knowledge of various software packages. Thus, many deep models have not been integrated into the clinical research workflows causing a gap between the state-of-the-art machine learning in medical applications and evaluation in clinical research procedures. In this paper, we propose “DeepInfer” – an open-source toolkit for developing and deploying deep learning models within the 3D Slicer medical image analysis platform. Utilizing a repository of task-specific models, DeepInfer allows clinical researchers and biomedical engineers to deploy a trained model selected from the public registry, and apply it to new data without the need for software development or configuration. As two practical use cases, we demonstrate the application of DeepInfer in prostate segmentation for targeted MRI-guided biopsy and identification of the target plane in 3D ultrasound for spinal injections. PMID:28615794

  7. Defect classification in sparsity-based structural health monitoring

    NASA Astrophysics Data System (ADS)

    Golato, Andrew; Ahmad, Fauzia; Santhanam, Sridhar; Amin, Moeness G.

    2017-05-01

    Guided waves have gained popularity in structural health monitoring (SHM) due to their ability to inspect large areas with little attenuation, while providing rich interactions with defects. For thin-walled structures, the propagating waves are Lamb waves, which are a complex but well understood type of guided waves. Recent works have cast the defect localization problem of Lamb wave based SHM within the sparse reconstruction framework. These methods make use of a linear model relating the measurements with the scene reflectivity under the assumption of point-like defects. However, most structural defects are not perfect points but tend to assume specific forms, such as surface cracks or internal cracks. Knowledge of the "type" of defects is useful in the assessment phase of SHM. In this paper, we present a dual purpose sparsity-based imaging scheme which, in addition to accurately localizing defects, properly classifies the defects present simultaneously. The proposed approach takes advantage of the bias exhibited by certain types of defects toward a specific Lamb wave mode. For example, some defects strongly interact with the anti-symmetric modes, while others strongly interact with the symmetric modes. We build model based dictionaries for the fundamental symmetric and anti-symmetric wave modes, which are then utilized in unison to properly localize and classify the defects present. Simulated data of surface and internal defects in a thin Aluminum plate are used to validate the proposed scheme.

  8. Intraoperative Ultrasound Guidance in Breast-Conserving Surgery Improves Cosmetic Outcomes and Patient Satisfaction: Results of a Multicenter Randomized Controlled Trial (COBALT).

    PubMed

    Haloua, Max H; Volders, José H; Krekel, Nicole M A; Lopes Cardozo, Alexander M F; de Roos, Wifred K; de Widt-Levert, Louise M; van der Veen, Henk; Rijna, Herman; Bergers, Elisabeth; Jóźwiak, Katarzyna; Meijer, Sybren; van den Tol, Petrousjka

    2016-01-01

    Ultrasound-guided breast-conserving surgery (USS) results in a significant reduction in both margin involvement and excision volumes (COBALT trial). Objective. The aim of the present study was to determine whether USS also leads to improvements in cosmetic outcome and patient satisfaction when compared with standard palpation-guided surgery (PGS). A total of 134 patients with T1–T2 invasive breast cancer were included in the COBALT trial (NTR2579) and randomized to either USS (65 patients) or PGS (69 patients). Cosmetic outcomes were assessed by a three-member panel using computerized software Breast Cancer Conservative Treatment cosmetic results (BCCT.- core) and by patient self-evaluation, including patient satisfaction. Time points for follow-up were 3, 6, and 12 months after surgery. Overall cosmetic outcome and patient satisfaction were scored on a 4-point Likert scale (excellent, good, fair, or poor), and outcomes were analyzed using a multilevel, mixed effect, proportional odds model for ordinal responses. Ultrasound-guided breast-conserving surgery achieved better cosmetic outcomes, with 20 % excellence overall and only 6 % rated as poor, whereas 14 % of PGS outcomes were rated excellent and 13 % as poor. USS also had consistently lower odds for worse cosmetic outcomes (odds ratio 0.55, p = 0.067) than PGS. The chance of having a worse outcome was significantly increased by a larger lumpectomy volume (ptrend = 0.002); a volume [40 cc showed odds 2.78-fold higher for a worse outcome than a volume B40 cc. USS resulted in higher patient satisfaction compared with PGS. Ultrasound-guided breast-conserving surgery achieved better overall cosmetic outcomes and patient satisfaction than PGS. Lumpectomy volumes[40 cc resulted in significantly worse cosmetic outcomes.

  9. Star Ware: The Amateur Astronomer's Guide to Choosing, Buying, and Using Telescopes and Accessories, 3rd Edition

    NASA Astrophysics Data System (ADS)

    Harrington, Philip S.

    2002-05-01

    Praise for the Second Edition of Star Ware "Star Ware is still a tour de force that any experienced amateur will find invaluable, and which hardware-minded beginners will thoroughly enjoy." -Robert Burnham, Sky & Telescope magazine "Star Ware condenses between two covers what would normally take a telescope buyer many months to accumulate." -John Shibley, Astronomy magazine Now more than ever, the backyard astronomer has a dazzling array of choices when it comes to telescope shopping-which can make choosing just the right sky-watching equipment a formidable challenge. In this revised and updated edition of Star Ware, the essential guide to buying astronomical equipment, award-winning astronomy writer Philip Harrington does the work for you, analyzing and exploring today's astronomy market and offering point-by-point comparisons of everything you need. Whether you're an experienced amateur astronomer or just getting started, Star Ware, Third Edition will prepare you to explore the farthest reaches of space with: Extensive, expanded reviews of leading models and accessories, including dozens of new products, to help you buy smart

  10. A clear, step-by-step guide to all aspects of purchasing everything from telescopes and binoculars to filters, mounts, lenses, cameras, film, star charts, guides and references, and much more Eleven new do-it-yourself projects for making unique astronomical equipment at home Easy tips on maintenance, photography, and star-mapping to help you get the most out of your telescope Lists of where to find everything astronomical, including Internet sites and Web resources; distributors, dealers, and conventions; and corporate listings for products and services

  11. The NIST Simple Guide for Evaluating and Expressing Measurement Uncertainty

    NASA Astrophysics Data System (ADS)

    Possolo, Antonio

    2016-11-01

    NIST has recently published guidance on the evaluation and expression of the uncertainty of NIST measurement results [1, 2], supplementing but not replacing B. N. Taylor and C. E. Kuyatt's (1994) Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results (NIST Technical Note 1297) [3], which tracks closely the Guide to the expression of uncertainty in measurement (GUM) [4], originally published in 1995 by the Joint Committee for Guides in Metrology of the International Bureau of Weights and Measures (BIPM). The scope of this Simple Guide, however, is much broader than the scope of both NIST Technical Note 1297 and the GUM, because it attempts to address several of the uncertainty evaluation challenges that have arisen at NIST since the 1990s, for example to include molecular biology, greenhouse gases and climate science measurements, and forensic science. The Simple Guide also expands the scope of those two other guidance documents by recognizing observation equations (that is, statistical models) as bona fide measurement models. These models are indispensable to reduce data from interlaboratory studies, to combine measurement results for the same measurand obtained by different methods, and to characterize the uncertainty of calibration and analysis functions used in the measurement of force, temperature, or composition of gas mixtures. This presentation reviews the salient aspects of the Simple Guide, illustrates the use of models and methods for uncertainty evaluation not contemplated in the GUM, and also demonstrates the NIST Uncertainty Machine [5] and the NIST Consensus Builder, which are web-based applications accessible worldwide that facilitate evaluations of measurement uncertainty and the characterization of consensus values in interlaboratory studies.

  12. Integrated Sensitivity Analysis Workflow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedman-Hill, Ernest J.; Hoffman, Edward L.; Gibson, Marcus J.

    2014-08-01

    Sensitivity analysis is a crucial element of rigorous engineering analysis, but performing such an analysis on a complex model is difficult and time consuming. The mission of the DART Workbench team at Sandia National Laboratories is to lower the barriers to adoption of advanced analysis tools through software integration. The integrated environment guides the engineer in the use of these integrated tools and greatly reduces the cycle time for engineering analysis.

  13. Preoperative Navigated Transcranial Magnetic Stimulation and Tractography to Guide Endoscopic Cystoventriculostomy: A Technical Note and Case Report.

    PubMed

    Hendrix, Philipp; Senger, Sebastian; Griessenauer, Christoph J; Simgen, Andreas; Linsler, Stefan; Oertel, Joachim

    2018-01-01

    To report a technique for endoscopic cystoventriculostomy guided by preoperative navigated transcranial magnetic stimulation (nTMS) and tractography in a patient with a large speech eloquent arachnoid cyst. A 74-year old woman presented with a seizure and subsequent persistent anomic aphasia from a progressive left-sided parietal arachnoid cyst. An endoscopic cystoventriculostomy and endoscope-assisted ventricle catheter placement were performed. Surgery was guided by preoperative nTMS and tractography to avoid eloquent language, motor, and visual pathways. Preoperative nTMS motor and language mapping were used to guide tractography of motor and language white matter tracts. The ideal locations of entry point and cystoventriculostomy as well as trajectory for stent-placement were determined preoperatively with a pseudo-3-dimensional model visualizing eloquent language, motor, and visual cortical and subcortical information. The early postoperative course was uneventful. At her 3-month follow-up visit, her language impairments had completely recovered. Additionally, magnetic resonance imaging demonstrated complete collapse of the arachnoid cyst. The combination of nTMS and tractography supports the identification of a safe trajectory for cystoventriculostomy in eloquent arachnoid cysts. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Multiple Active Contours Guided by Differential Evolution for Medical Image Segmentation

    PubMed Central

    Cruz-Aceves, I.; Avina-Cervantes, J. G.; Lopez-Hernandez, J. M.; Rostro-Gonzalez, H.; Garcia-Capulin, C. H.; Torres-Cisneros, M.; Guzman-Cabrera, R.

    2013-01-01

    This paper presents a new image segmentation method based on multiple active contours guided by differential evolution, called MACDE. The segmentation method uses differential evolution over a polar coordinate system to increase the exploration and exploitation capabilities regarding the classical active contour model. To evaluate the performance of the proposed method, a set of synthetic images with complex objects, Gaussian noise, and deep concavities is introduced. Subsequently, MACDE is applied on datasets of sequential computed tomography and magnetic resonance images which contain the human heart and the human left ventricle, respectively. Finally, to obtain a quantitative and qualitative evaluation of the medical image segmentations compared to regions outlined by experts, a set of distance and similarity metrics has been adopted. According to the experimental results, MACDE outperforms the classical active contour model and the interactive Tseng method in terms of efficiency and robustness for obtaining the optimal control points and attains a high accuracy segmentation. PMID:23983809

  15. Beyond the Dedicated Education Unit: Using Cognitive Load Theory to Guide Clinical Placement.

    PubMed

    Mulcock, Pamela McPhie; Grassley, Jane; Davis, Michael; White, Kathryn

    2017-02-01

    Navigating multiple instructors and clinical agencies can impair students' learning by increasing their cognitive load and perceived stress. This study used cognitive load theory to guide the home base clinical model (HBCM), which assigned students to the same faculty and hospital unit for two consecutive medical-surgical clinical courses. The study used a quasi-experimental three-group design to evaluate the effects of the HBCM on students' perceived stress, compared with groups who changed hospital or instructor. A 10-point visual analog scale measured students' perceived stress on nine clinical tasks. The study recruited 140 participants. Reductions in mean stress were greater for the HBCM groups than the other two groups. The study findings challenge the current practice of placing students with changing faculty and facilities. The HBCM demonstrates potential as an effective model for increasing students' ability to learn by decreasing their cognitive load and subsequent stress in their clinical placements. [J Nurs Educ. 2017;56(2):105-109.]. Copyright 2017, SLACK Incorporated.

  16. MAGDAIRE: A Model to Foster Pre-Service Teachers' Ability in Integrating ICT and Teaching in Taiwan

    ERIC Educational Resources Information Center

    Chang, Chun-Yen; Chien, Yu-Ta; Chang, Yueh-Hsia; Lin, Chen-Yung

    2012-01-01

    This report describes our efforts in fostering Taiwanese pre-service teachers' ability to integrate information and communication technology (ICT) and teaching. The current state of science teacher education and ICT policies in Taiwan are documented briefly. The course model, MAGDAIRE (abbreviated from Modeled Analysis, Guided Development,…

  17. Laser induced fluorescence as a diagnostic tool integrated into a scanning fiber endoscope for mouse imaging

    NASA Astrophysics Data System (ADS)

    Brown, Christopher M.; Maggio-Price, Lillian; Seibel, Eric J.

    2007-02-01

    Scanning fiber endoscope (SFE) technology has shown promise as a minimally invasive optical imaging tool. To date, it is capable of capturing full-color 500-line images, at 15 Hz frame rate in vivo, as a 1.6 mm diameter endoscope. The SFE uses a singlemode optical fiber actuated at mechanical resonance to scan a light spot over tissue while backscattered or fluorescent light at each pixel is detected in time series using several multimode optical fibers. We are extending the capability of the SFE from a RGB reflectance imaging device to a diagnostic tool by imaging laser induced fluorescence (LIF) in tissue, allowing for correlation of endogenous fluorescence to tissue state. Design of the SFE for diagnostic imaging is guided by a comparison of single point spectra acquired from an inflammatory bowel disease (IBD) model to tissue histology evaluated by a pathologist. LIF spectra were acquired by illuminating tissue with a 405 nm light source and detecting intrinsic fluorescence with a multimode optical fiber. The IBD model used in this study was mdr1a-/- mice, where IBD was modulated by infection with Helicobacter bilis. IBD lesions in the mouse model ranged from mild to marked hyperplasia and dysplasia, from the distal colon to the cecum. A principle components analysis (PCA) was conducted on single point spectra of control and IBD tissue. PCA allowed for differentiation between healthy and dysplastic tissue, indicating that emission wavelengths from 620 - 650 nm were best able to differentiate diseased tissue and inflammation from normal healthy tissue.

  18. ATLAS, an integrated structural analysis and design system. Volume 1: ATLAS user's guide

    NASA Technical Reports Server (NTRS)

    Dreisbach, R. L. (Editor)

    1979-01-01

    Some of the many analytical capabilities provided by the ATLAS Version 4.0 System in the logical sequence are described in which model-definition data are prepared and the subsequent computer job is executed. The example data presented and the fundamental technical considerations that are highlighted can be used as guides during the problem solving process. This guide does not describe the details of the ATLAS capabilities, but provides an introduction to the new user of ATLAS to the level at which the complete array of capabilities described in the ATLAS User's Manual can be exploited fully.

  19. FPCAS3D User's guide: A three dimensional full potential aeroelastic program, version 1

    NASA Technical Reports Server (NTRS)

    Bakhle, Milind A.

    1995-01-01

    The FPCAS3D computer code has been developed for aeroelastic stability analysis of bladed disks such as those in fans, compressors, turbines, propellers, or propfans. The aerodynamic analysis used in this code is based on the unsteady three-dimensional full potential equation which is solved for a blade row. The structural analysis is based on a finite-element model for each blade. Detailed explanations of the aerodynamic analysis, the numerical algorithms, and the aeroelastic analysis are not given in this report. This guide can be used to assist in the preparation of the input data required by the FPCAS3D code. A complete description of the input data is provided in this report. In addition, six examples, including inputs and outputs, are provided.

  20. FPCAS2D user's guide, version 1.0

    NASA Technical Reports Server (NTRS)

    Bakhle, Milind A.

    1994-01-01

    The FPCAS2D computer code has been developed for aeroelastic stability analysis of bladed disks such as those in fans, compressors, turbines, propellers, or propfans. The aerodynamic analysis used in this code is based on the unsteady two-dimensional full potential equation which is solved for a cascade of blades. The structural analysis is based on a two degree-of-freedom rigid typical section model for each blade. Detailed explanations of the aerodynamic analysis, the numerical algorithms, and the aeroelastic analysis are not given in this report. This guide can be used to assist in the preparation of the input data required by the FPCAS2D code. A complete description of the input data is provided in this report. In addition, four test cases, including inputs and outputs, are provided.

  21. A guide to differences between stochastic point-source and stochastic finite-fault simulations

    USGS Publications Warehouse

    Atkinson, G.M.; Assatourians, K.; Boore, D.M.; Campbell, K.; Motazedian, D.

    2009-01-01

    Why do stochastic point-source and finite-fault simulation models not agree on the predicted ground motions for moderate earthquakes at large distances? This question was posed by Ken Campbell, who attempted to reproduce the Atkinson and Boore (2006) ground-motion prediction equations for eastern North America using the stochastic point-source program SMSIM (Boore, 2005) in place of the finite-source stochastic program EXSIM (Motazedian and Atkinson, 2005) that was used by Atkinson and Boore (2006) in their model. His comparisons suggested that a higher stress drop is needed in the context of SMSIM to produce an average match, at larger distances, with the model predictions of Atkinson and Boore (2006) based on EXSIM; this is so even for moderate magnitudes, which should be well-represented by a point-source model. Why? The answer to this question is rooted in significant differences between point-source and finite-source stochastic simulation methodologies, specifically as implemented in SMSIM (Boore, 2005) and EXSIM (Motazedian and Atkinson, 2005) to date. Point-source and finite-fault methodologies differ in general in several important ways: (1) the geometry of the source; (2) the definition and application of duration; and (3) the normalization of finite-source subsource summations. Furthermore, the specific implementation of the methods may differ in their details. The purpose of this article is to provide a brief overview of these differences, their origins, and implications. This sets the stage for a more detailed companion article, "Comparing Stochastic Point-Source and Finite-Source Ground-Motion Simulations: SMSIM and EXSIM," in which Boore (2009) provides modifications and improvements in the implementations of both programs that narrow the gap and result in closer agreement. These issues are important because both SMSIM and EXSIM have been widely used in the development of ground-motion prediction equations and in modeling the parameters that control observed ground motions.

  1. Deformable Image Registration based on Similarity-Steered CNN Regression.

    PubMed

    Cao, Xiaohuan; Yang, Jianhua; Zhang, Jun; Nie, Dong; Kim, Min-Jeong; Wang, Qian; Shen, Dinggang

    2017-09-01

    Existing deformable registration methods require exhaustively iterative optimization, along with careful parameter tuning, to estimate the deformation field between images. Although some learning-based methods have been proposed for initiating deformation estimation, they are often template-specific and not flexible in practical use. In this paper, we propose a convolutional neural network (CNN) based regression model to directly learn the complex mapping from the input image pair (i.e., a pair of template and subject) to their corresponding deformation field. Specifically, our CNN architecture is designed in a patch-based manner to learn the complex mapping from the input patch pairs to their respective deformation field. First, the equalized active-points guided sampling strategy is introduced to facilitate accurate CNN model learning upon a limited image dataset. Then, the similarity-steered CNN architecture is designed, where we propose to add the auxiliary contextual cue, i.e., the similarity between input patches, to more directly guide the learning process. Experiments on different brain image datasets demonstrate promising registration performance based on our CNN model. Furthermore, it is found that the trained CNN model from one dataset can be successfully transferred to another dataset, although brain appearances across datasets are quite variable.

  2. A general causal model to guide alcohol, tobacco, and illicit drug prevention: assessing the research evidence.

    PubMed

    Birckmayer, Johanna D; Holder, Harold D; Yacoubian, George S; Friend, Karen B

    2004-01-01

    The problems associated with the use of alcohol, tobacco, and other drugs (ATOD) extract a significant health, social, and economic toll on American society. While the field of substance abuse prevention has made great strides during the past decade, two major challenges remain. First, the field has been disorganized and fragmented with respect to its research and prevention practices; that is, there are often separate ATOD prevention "specialists." Second, both the prevention researchers who test the efficacy of specific prevention strategies and the practitioners who implement prevention efforts often lack an overall perspective to guide strategy selection. To address these limitations, we present an ATOD causal model that seeks to identify those variables (Domains) that are theoretically salient and empirically connected across alcohol, tobacco, and illicit drugs. For the researcher, the model demonstrates important commonalities, as well as gaps, in the literature. For the practitioner, the model is a means to recognize both the complexity of the community system that produces ATOD problems and the multiple intervention points that are possible within this system. Researchers and practitioners are thus challenged to work synergistically to find effective and cost-effective approaches to change or reduce ATOD use and associated problems.

  3. Airport-Noise Levels and Annoyance Model (ALAMO) user's guide

    NASA Technical Reports Server (NTRS)

    Deloach, R.; Donaldson, J. L.; Johnson, M. J.

    1986-01-01

    A guide for the use of the Airport-Noise Level and Annoyance MOdel (ALAMO) at the Langley Research Center computer complex is provided. This document is divided into 5 primary sections, the introduction, the purpose of the model, and an in-depth description of the following subsystems: baseline, noise reduction simulation and track analysis. For each subsystem, the user is provided with a description of architecture, an explanation of subsystem use, sample results, and a case runner's check list. It is assumed that the user is familiar with the operations at the Langley Research Center (LaRC) computer complex, the Network Operating System (NOS 1.4) and CYBER Control Language. Incorporated within the ALAMO model is a census database system called SITE II.

  4. General model for the pointing error analysis of Risley-prism system based on ray direction deviation in light refraction

    NASA Astrophysics Data System (ADS)

    Zhang, Hao; Yuan, Yan; Su, Lijuan; Huang, Fengzhen; Bai, Qing

    2016-09-01

    The Risley-prism-based light beam steering apparatus delivers superior pointing accuracy and it is used in imaging LIDAR and imaging microscopes. A general model for pointing error analysis of the Risley prisms is proposed in this paper, based on ray direction deviation in light refraction. This model captures incident beam deviation, assembly deflections, and prism rotational error. We derive the transmission matrixes of the model firstly. Then, the independent and cumulative effects of different errors are analyzed through this model. Accuracy study of the model shows that the prediction deviation of pointing error for different error is less than 4.1×10-5° when the error amplitude is 0.1°. Detailed analyses of errors indicate that different error sources affect the pointing accuracy to varying degree, and the major error source is the incident beam deviation. The prism tilting has a relative big effect on the pointing accuracy when prism tilts in the principal section. The cumulative effect analyses of multiple errors represent that the pointing error can be reduced by tuning the bearing tilting in the same direction. The cumulative effect of rotational error is relative big when the difference of these two prism rotational angles equals 0 or π, while it is relative small when the difference equals π/2. The novelty of these results suggests that our analysis can help to uncover the error distribution and aid in measurement calibration of Risley-prism systems.

  5. Ligand-guided optimization of CXCR4 homology models for virtual screening using a multiple chemotype approach

    NASA Astrophysics Data System (ADS)

    Neves, Marco A. C.; Simões, Sérgio; Sá e Melo, M. Luisa

    2010-12-01

    CXCR4 is a G-protein coupled receptor for CXCL12 that plays an important role in human immunodeficiency virus infection, cancer growth and metastasization, immune cell trafficking and WHIM syndrome. In the absence of an X-ray crystal structure, theoretical modeling of the CXCR4 receptor remains an important tool for structure-function analysis and to guide the discovery of new antagonists with potential clinical use. In this study, the combination of experimental data and molecular modeling approaches allowed the development of optimized ligand-receptor models useful for elucidation of the molecular determinants of small molecule binding and functional antagonism. The ligand-guided homology modeling approach used in this study explicitly re-shaped the CXCR4 binding pocket in order to improve discrimination between known CXCR4 antagonists and random decoys. Refinement based on multiple test-sets with small compounds from single chemotypes provided the best early enrichment performance. These results provide an important tool for structure-based drug design and virtual ligand screening of new CXCR4 antagonists.

  6. Student Analysis of Handout Development based on Guided Discovery Method in Process Evaluation and Learning Outcomes of Biology

    NASA Astrophysics Data System (ADS)

    Nerita, S.; Maizeli, A.; Afza, A.

    2017-09-01

    Process Evaluation and Learning Outcomes of Biology subjects discusses the evaluation process in learning and application of designed and processed learning outcomes. Some problems found during this subject was the student difficult to understand the subject and the subject unavailability of learning resources that can guide and make students independent study. So, it necessary to develop a learning resource that can make active students to think and to make decisions with the guidance of the lecturer. The purpose of this study is to produce handout based on guided discovery method that match the needs of students. The research was done by using 4-D models and limited to define phase that is student requirement analysis. Data obtained from the questionnaire and analyzed descriptively. The results showed that the average requirement of students was 91,43%. Can be concluded that students need a handout based on guided discovery method in the learning process.

  7. Maxillary "All-On-Four" treatment using zygomatic implants. A mechanical analysis.

    PubMed

    de Moraes, P H; Olate, S; Nóbilo, M de Arruda; Asprino, L; de Moraes, M; Barbosa, J de Albergaría

    2016-04-01

    Zygomatic implants may be used for dental rehabilitation in atrophic maxillae. The aim of this study was to establish experimentally the areas of stress distribution using 2 kinds of "All-On-Four" maxillary procedures. The best position to insert the implants was selected using polyurethane craniomaxillary models and surgical guides were made. Group 1 was designed with two posterior zygomatic implants and two conventional anterior implants, and group 2 with two posterior zygomatic implants and two anterior zygomatic implants. A titanium bar was built to link the 4 implants in both groups. Photoelastic replicas of these models were made and the implants were inserted using the surgical guides. An Instrom 4411 testing machine was used to perform a unilateral compressive loading at the level of the right first molar until 2mm of displacement was obtained. Group 1 showed a high strain concentration in the right lateral orbital region at the level of the apex of the zygomatic implant. Less strain was noticed at the apical levels of the conventional implants in the anterior sector and of the contralateral zygomatic implant. Group 2 showed high strains in the lateral inferior orbital area. The load was low in the alveolar bone sector. Zygomatic bone and paranasal structures are loaded at high levels when zygomatic implants are used to stabilize a full maxillary prosthodontic rehabilitation on 4 implants. The use of 4 zygomatic implants loads the alveolar bone to a lower extent and seems better suited from a mechanical point of view than the use of 2 zygomatic implants. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  8. Genetic Algorithm-Based Model Order Reduction of Aeroservoelastic Systems with Consistant States

    NASA Technical Reports Server (NTRS)

    Zhu, Jin; Wang, Yi; Pant, Kapil; Suh, Peter M.; Brenner, Martin J.

    2017-01-01

    This paper presents a model order reduction framework to construct linear parameter-varying reduced-order models of flexible aircraft for aeroservoelasticity analysis and control synthesis in broad two-dimensional flight parameter space. Genetic algorithms are used to automatically determine physical states for reduction and to generate reduced-order models at grid points within parameter space while minimizing the trial-and-error process. In addition, balanced truncation for unstable systems is used in conjunction with the congruence transformation technique to achieve locally optimal realization and weak fulfillment of state consistency across the entire parameter space. Therefore, aeroservoelasticity reduced-order models at any flight condition can be obtained simply through model interpolation. The methodology is applied to the pitch-plant model of the X-56A Multi-Use Technology Testbed currently being tested at NASA Armstrong Flight Research Center for flutter suppression and gust load alleviation. The present studies indicate that the reduced-order model with more than 12× reduction in the number of states relative to the original model is able to accurately predict system response among all input-output channels. The genetic-algorithm-guided approach exceeds manual and empirical state selection in terms of efficiency and accuracy. The interpolated aeroservoelasticity reduced order models exhibit smooth pole transition and continuously varying gains along a set of prescribed flight conditions, which verifies consistent state representation obtained by congruence transformation. The present model order reduction framework can be used by control engineers for robust aeroservoelasticity controller synthesis and novel vehicle design.

  9. Measurement of math beliefs and their associations with math behaviors in college students.

    PubMed

    Hendy, Helen M; Schorschinsky, Nancy; Wade, Barbara

    2014-12-01

    Our purpose in the present study was to expand understanding of math beliefs in college students by developing 3 new psychometrically tested scales as guided by expectancy-value theory, self-efficacy theory, and health belief model. Additionally, we identified which math beliefs (and which theory) best explained variance in math behaviors and performance by college students and which students were most likely to have problematic math beliefs. Study participants included 368 college math students who completed questionnaires to report math behaviors (attending class, doing homework, reading textbooks, asking for help) and used a 5-point rating scale to indicate a variety of math beliefs. For a subset of 84 students, math professors provided final math grades. Factor analyses produced a 10-item Math Value Scale with 2 subscales (Class Devaluation, No Future Value), a 7-item single-dimension Math Confidence Scale, and an 11-item Math Barriers Scale with 2 subscales (Math Anxiety, Discouraging Words). Hierarchical multiple regression revealed that high levels of the newly discovered class devaluation belief (guided by expectancy-value theory) were most consistently associated with poor math behaviors in college students, with high math anxiety (guided by health belief model) and low math confidence (guided by self-efficacy theory) also found to be significant. Analyses of covariance revealed that younger and male students were at increased risk for class devaluation and older students were at increased risk for poor math confidence. (c) 2014 APA, all rights reserved.

  10. The use of virtual fiducials in image-guided kidney surgery

    NASA Astrophysics Data System (ADS)

    Glisson, Courtenay; Ong, Rowena; Simpson, Amber; Clark, Peter; Herrell, S. D.; Galloway, Robert

    2011-03-01

    The alignment of image-space to physical-space lies at the heart of all image-guided procedures. In intracranial surgery, point-based registrations can be used with either skin-affixed or bone-implanted extrinsic objects called fiducial markers. The advantages of point-based registration techniques are that they are robust, fast, and have a well developed mathematical foundation for the assessment of registration quality. In abdominal image-guided procedures such techniques have not been successful. It is difficult to accurately locate sufficient homologous intrinsic points in imagespace and physical-space, and the implantation of extrinsic fiducial markers would constitute "surgery before the surgery." Image-space to physical-space registration for abdominal organs has therefore been dominated by surfacebased registration techniques which are iterative, prone to local minima, sensitive to initial pose, and sensitive to percentage coverage of the physical surface. In our work in image-guided kidney surgery we have developed a composite approach using "virtual fiducials." In an open kidney surgery, the perirenal fat is removed and the surface of the kidney is dotted using a surgical marker. A laser range scanner (LRS) is used to obtain a surface representation and matching high definition photograph. A surface to surface registration is performed using a modified iterative closest point (ICP) algorithm. The dots are extracted from the high definition image and assigned the three dimensional values from the LRS pixels over which they lie. As the surgery proceeds, we can then use point-based registrations to re-register the spaces and track deformations due to vascular clamping and surgical tractions.

  11. Sensitivity study of experimental measures for the nuclear liquid-gas phase transition in the statistical multifragmentation model

    NASA Astrophysics Data System (ADS)

    Lin, W.; Ren, P.; Zheng, H.; Liu, X.; Huang, M.; Wada, R.; Qu, G.

    2018-05-01

    The experimental measures of the multiplicity derivatives—the moment parameters, the bimodal parameter, the fluctuation of maximum fragment charge number (normalized variance of Zmax, or NVZ), the Fisher exponent (τ ), and the Zipf law parameter (ξ )—are examined to search for the liquid-gas phase transition in nuclear multifragmention processes within the framework of the statistical multifragmentation model (SMM). The sensitivities of these measures are studied. All these measures predict a critical signature at or near to the critical point both for the primary and secondary fragments. Among these measures, the total multiplicity derivative and the NVZ provide accurate measures for the critical point from the final cold fragments as well as the primary fragments. The present study will provide a guide for future experiments and analyses in the study of the nuclear liquid-gas phase transition.

  12. SOM guided fuzzy logic prospectivity model for gold in the Häme Belt, southwestern Finland

    NASA Astrophysics Data System (ADS)

    Leväniemi, Hanna; Hulkki, Helena; Tiainen, Markku

    2017-04-01

    This study investigated gold prospectivity in the Paleoproterozoic Häme Belt, located in southwestern Finland. The Häme Belt comprises calc-alkaline and tholeitic volcanic rocks, migmatites, granitoids, and mafic to ultramafic intrusions. Mineral exploration in the region has resulted in the discovery of several gold occurrences during recent decades; however, no prospectivity modeling for gold has yet been conducted. This study integrated till geochemical and geophysical data to examine and extract data characteristics critical for gold occurrences. Modeling was guided by self-organizing map (SOM) analysis to define essential data associations and to aid in model input data selection and generation. The final fuzzy logic prospectivity model map yielded high predictability values for most known Au or Cu-Au occurrences, but also highlighted new targets for exploration.

  13. Clinical prediction rule for delayed hemothorax after minor thoracic injury: a multicentre derivation and validation study

    PubMed Central

    Émond, Marcel; Guimont, Chantal; Chauny, Jean-Marc; Daoust, Raoul; Bergeron, Éric; Vanier, Laurent; Moore, Lynne; Plourde, Miville; Kuimi, Batomen; Boucher, Valérie; Allain-Boulé, Nadine; Le Sage, Natalie

    2017-01-01

    Background: About 75% of patients with minor thoracic injury are discharged after an emergency department visit. However, complications such as delayed hemothorax can occur. We sought to derive and validate a clinical decision rule to predict hemothorax in patients discharged from the emergency department. Methods: We conducted a 6-year prospective cohort study in 4 university-affiliated emergency departments. Patients aged 16 years or older presenting with a minor thoracic injury were assessed at 5 time points (initial visit and 7, 14, 30 and 90 d after the injury). Radiologists' reports were reviewed for the presence of hemothorax. We used log-binomial regression models to identify predictors of hemothorax. Results: A total of 1382 patients were included: 830 in the derivation phase and 552 in the validation phase. Of these, 151 (10.9%) had hemothorax at the 14-day follow-up. Patients 65 years of age or older represented 25.3% (210/830) and 23.7% (131/552) of the derivation and validation cohorts, respectively. The final clinical decision rule included a combination of age (> 70 yr, 2 points; 45-70 yr, 1 point), fracture of any high to mid thorax rib (ribs 3-9, 2 points) and presence of 3 or more rib fractures (1 point). Twenty (30.8%) of the 65 high-risk patients (score ≥ 4) experienced hemothorax during the follow-up period. The clinical decision rule had a high specificity (90.7%, 95% confidence interval 87.7%-93.1%) in this high-risk group, thus guiding appropriate post-emergency care. Interpretation: One patient out of every 10 presented with delayed hemothorax after discharge from the emergency department. Implementation of this validated clinical decision rule for minor thoracic injury could guide emergency discharge plans. PMID:28611156

  14. Terminal Sliding Mode Tracking Controller Design for Automatic Guided Vehicle

    NASA Astrophysics Data System (ADS)

    Chen, Hongbin

    2018-03-01

    Based on sliding mode variable structure control theory, the path tracking problem of automatic guided vehicle is studied, proposed a controller design method based on the terminal sliding mode. First of all, through analyzing the characteristics of the automatic guided vehicle movement, the kinematics model is presented. Then to improve the traditional expression of terminal sliding mode, design a nonlinear sliding mode which the convergence speed is faster than the former, verified by theoretical analysis, the design of sliding mode is steady and fast convergence in the limited time. Finally combining Lyapunov method to design the tracking control law of automatic guided vehicle, the controller can make the automatic guided vehicle track the desired trajectory in the global sense as well as in finite time. The simulation results verify the correctness and effectiveness of the control law.

  15. A simple 5-point scoring system, NaURSE (Na+, urea, respiratory rate and shock index in the elderly), predicts in-hospital mortality in oldest old.

    PubMed

    Wilson, Alexander H; Kidd, Andrew C; Skinner, Jane; Musonda, Patrick; Pai, Yogish; Lunt, Claire J; Butchart, Catherine; Soiza, Roy L; Potter, John F; Myint, Phyo Kyaw

    2014-05-01

    the mortality is high in acutely ill oldest old patients. Understanding the prognostic factors which influence mortality will help clinicians make appropriate management decisions. we analysed prospective mortality audit data (November 2008 to January 2009) to identify variables associated with in-patient mortality in oldest old. We selected those with P < 0.10 from univariate analysis and determined at which cut-point they served as the strongest predictor of mortality. Using these cut-off points, we constructed multivariate logistic regression models. A 5-point score was derived from cut-off points which were significantly associated with mortality tested in a smaller independent re-audit sample conducted in October 2011. a total of 405 patients (mean 93.5 ± 2.7 years) were included in the study. The mean length of stay was 18.5 ± 42.4 days and 13.8% died as in-patients. Variables (cut-off values) found to be significantly associated with in-patient mortality were admission sodium (>145 mmol/l), urea (≥14 mmol/l), respiratory rate (>20/min) and shock index (>1.0): creating a 5-point score (NaURSE: NaURS in the Elderly). The crude mortality rates were 9.5, 19.9, 34.4, 66.7, and 100% for scores 0, 1, 2, 3 and 4, respectively. Using the cut-off point of ≥2, the NaURSE score has a specificity of 87% (83.1-90.3) and sensitivity of 39% (28.5-50.0), with an AUC value of 0.69 (0.63-0.76). An external independent validation study (n = 121) showed similar results. the NaURSE score may be particularly useful in identifying oldest old who are likely to die in that admission to guide appropriate care.

  16. Patient-specific targeting guides compared with traditional instrumentation for glenoid component placement in shoulder arthroplasty: a multi-surgeon study in 70 arthritic cadaver specimens.

    PubMed

    Throckmorton, Thomas W; Gulotta, Lawrence V; Bonnarens, Frank O; Wright, Stephen A; Hartzell, Jeffrey L; Rozzi, William B; Hurst, Jason M; Frostick, Simon P; Sperling, John W

    2015-06-01

    The purpose of this study was to compare the accuracy of patient-specific guides for total shoulder arthroplasty (TSA) with traditional instrumentation in arthritic cadaver shoulders. We hypothesized that the patient-specific guides would place components more accurately than standard instrumentation. Seventy cadaver shoulders with radiographically confirmed arthritis were randomized in equal groups to 5 surgeons of varying experience levels who were not involved in development of the patient-specific guidance system. Specimens were then randomized to patient-specific guides based off of computed tomography scanning, standard instrumentation, and anatomic TSA or reverse TSA. Variances in version or inclination of more than 10° and more than 4 mm in starting point were considered indications of significant component malposition. TSA glenoid components placed with patient-specific guides averaged 5° of deviation from the intended position in version and 3° in inclination; those with standard instrumentation averaged 8° of deviation in version and 7° in inclination. These differences were significant for version (P = .04) and inclination (P = .01). Multivariate analysis of variance to compare the overall accuracy for the entire cohort (TSA and reverse TSA) revealed patient-specific guides to be significantly more accurate (P = .01) for the combined vectors of version and inclination. Patient-specific guides also had fewer instances of significant component malposition than standard instrumentation did. Patient-specific targeting guides were more accurate than traditional instrumentation and had fewer instances of component malposition for glenoid component placement in this multi-surgeon cadaver study of arthritic shoulders. Long-term clinical studies are needed to determine if these improvements produce improved functional outcomes. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  17. Modelling guided waves in the Alaskan-Aleutian subduction zone

    NASA Astrophysics Data System (ADS)

    Coulson, Sophie; Garth, Thomas; Reitbrock, Andreas

    2016-04-01

    Subduction zone guided wave arrivals from intermediate depth earthquakes (70-300 km depth) have a huge potential to tell us about the velocity structure of the subducting oceanic crust as it dehydrates at these depths. We see guided waves as the oceanic crust has a slower seismic velocity than the surrounding material, and so high frequency energy is retained and delayed in the crustal material. Lower frequency energy is not retained in this crustal waveguide and so travels at faster velocities of the surrounding material. This gives a unique observation at the surface with low frequency energy arriving before the higher frequencies. We constrain this guided wave dispersion by comparing the waveforms recorded in real subduction zones with simulated waveforms, produced using finite difference full waveform modelling techniques. This method has been used to show that hydrated minerals in the oceanic crust persist to much greater depths than accepted thermal petrological subduction zone models would suggest in Northern Japan (Garth & Rietbrock, 2014a), and South America (Garth & Rietbrock, in prep). These observations also suggest that the subducting oceanic mantle may be highly hydrated at intermediate depth by dipping normal faults (Garth & Rietbrock 2014b). We use this guided wave analysis technique to constrain the velocity structure of the down going ~45 Ma Pacific plate beneath Alaska. Dispersion analysis is primarily carried out on guided wave arrivals recorded on the Alaskan regional seismic network. Earthquake locations from global earthquake catalogues (ISC and PDE) and regional earthquake locations from the AEIC (Alaskan Earthquake Information Centre) catalogue are used to constrain the slab geometry and to identify potentially dispersive events. Dispersed arrivals are seen at stations close to the trench, with high frequency (>2 Hz) arrivals delayed by 2 - 4 seconds. This dispersion is analysed to constrain the velocity and width of the proposed waveguide. The velocity structure of this relatively young subducting plate is compared to the velocity structure resolved in the older oceanic lithosphere subducted beneath Northern Japan. We also use guided wave observations to investigate the thickness and low velocity structure of the subducting Yakutat terrain. Additionally we discuss the dependence of the inferred slab geometry on the earthquake catalogues that are used.

  18. The Iroquois People: We Are All Born of the Same Mother. A Reference Guide, Title VII.

    ERIC Educational Resources Information Center

    Rosenblat, Marilyn L.; And Others

    Written for classroom teachers grades K-12, this reference guide on the Iroquois Indians provides an overview of history, religion, and culture and points out contributions of the Iroquois people. Concentrating on chronological history, the guide begins with formation of the Iroquois Confederacy (later a League of Six Nations) and continues after…

  19. A guide to Bayesian model selection for ecologists

    USGS Publications Warehouse

    Hooten, Mevin B.; Hobbs, N.T.

    2015-01-01

    The steady upward trend in the use of model selection and Bayesian methods in ecological research has made it clear that both approaches to inference are important for modern analysis of models and data. However, in teaching Bayesian methods and in working with our research colleagues, we have noticed a general dissatisfaction with the available literature on Bayesian model selection and multimodel inference. Students and researchers new to Bayesian methods quickly find that the published advice on model selection is often preferential in its treatment of options for analysis, frequently advocating one particular method above others. The recent appearance of many articles and textbooks on Bayesian modeling has provided welcome background on relevant approaches to model selection in the Bayesian framework, but most of these are either very narrowly focused in scope or inaccessible to ecologists. Moreover, the methodological details of Bayesian model selection approaches are spread thinly throughout the literature, appearing in journals from many different fields. Our aim with this guide is to condense the large body of literature on Bayesian approaches to model selection and multimodel inference and present it specifically for quantitative ecologists as neutrally as possible. We also bring to light a few important and fundamental concepts relating directly to model selection that seem to have gone unnoticed in the ecological literature. Throughout, we provide only a minimal discussion of philosophy, preferring instead to examine the breadth of approaches as well as their practical advantages and disadvantages. This guide serves as a reference for ecologists using Bayesian methods, so that they can better understand their options and can make an informed choice that is best aligned with their goals for inference.

  20. Latino Adolescents' Academic Motivation: The Role of Siblings

    ERIC Educational Resources Information Center

    Alfaro, Edna C.; Umana-Taylor, Adriana J.

    2010-01-01

    Guided by an ecological perspective, two competing models were tested to examine how sibling relationship quality directly predicted or interacted with academic support from siblings to predict Latino adolescents' academic motivation (N = 258). Gender differences were examined utilizing multiple group analysis in structural equation modeling.…

  1. Models of railroad passenger-car requirements in the northeast corridor : volume II user's guide

    DOT National Transportation Integrated Search

    1976-09-30

    Models and techniques for determining passenger-car requirements in railroad service were developed and applied by a research project of which this is the final report. The report is published in two volumes. The solution and analysis of the Northeas...

  2. Rationale and design of the NO-PARTY trial: near-zero fluoroscopic exposure during catheter ablation of supraventricular arrhythmias in young patients.

    PubMed

    Casella, Michela; Dello Russo, Antonio; Pelargonio, Gemma; Bongiorni, Maria Grazia; Del Greco, Maurizio; Piacenti, Marcello; Andreassi, Maria Grazia; Santangeli, Pasquale; Bartoletti, Stefano; Moltrasio, Massimo; Fassini, Gaetano; Marini, Massimiliano; Di Cori, Andrea; Di Biase, Luigi; Fiorentini, Cesare; Zecchi, Paolo; Natale, Andrea; Picano, Eugenio; Tondo, Claudio

    2012-10-01

    Radiofrequency catheter ablation is the mainstay of therapy for supraventricular tachyarrhythmias. Conventional radiofrequency catheter ablation requires the use of fluoroscopy, thus exposing patients to ionising radiation. The feasibility and safety of non-fluoroscopic radiofrequency catheter ablation has been recently reported in a wide range of supraventricular tachyarrhythmias using the EnSite NavX™ mapping system. The NO-PARTY is a multi-centre, randomised controlled trial designed to test the hypothesis that catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system results in a clinically significant reduction in exposure to ionising radiation compared with conventional catheter ablation. The study will randomise 210 patients undergoing catheter ablation of supraventricular tachyarrhythmias to either a conventional ablation technique or one guided by the EnSite NavX™ mapping system. The primary end-point is the reduction of the radiation dose to the patient. Secondary end-points include procedural success, reduction of the radiation dose to the operator, and a cost-effectiveness analysis. In a subgroup of patients, we will also evaluate the radiobiological effectiveness of dose reduction by assessing acute chromosomal DNA damage in peripheral blood lymphocytes. NO-PARTY will determine whether radiofrequency catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system is a suitable and cost-effective approach to achieve a clinically significant reduction in ionising radiation exposure for both patient and operator.

  3. Understanding the Impact of Interventions to Prevent Antimicrobial Resistant Infections in the Long-Term Care Facility: A Review and Practical Guide to Mathematical Modeling.

    PubMed

    Rosello, Alicia; Horner, Carolyne; Hopkins, Susan; Hayward, Andrew C; Deeny, Sarah R

    2017-02-01

    OBJECTIVES (1) To systematically search for all dynamic mathematical models of infectious disease transmission in long-term care facilities (LTCFs); (2) to critically evaluate models of interventions against antimicrobial resistance (AMR) in this setting; and (3) to develop a checklist for hospital epidemiologists and policy makers by which to distinguish good quality models of AMR in LTCFs. METHODS The CINAHL, EMBASE, Global Health, MEDLINE, and Scopus databases were systematically searched for studies of dynamic mathematical models set in LTCFs. Models of interventions targeting methicillin-resistant Staphylococcus aureus in LTCFs were critically assessed. Using this analysis, we developed a checklist for good quality mathematical models of AMR in LTCFs. RESULTS AND DISCUSSION Overall, 18 papers described mathematical models that characterized the spread of infectious diseases in LTCFs, but no models of AMR in gram-negative bacteria in this setting were described. Future models of AMR in LTCFs require a more robust methodology (ie, formal model fitting to data and validation), greater transparency regarding model assumptions, setting-specific data, realistic and current setting-specific parameters, and inclusion of movement dynamics between LTCFs and hospitals. CONCLUSIONS Mathematical models of AMR in gram-negative bacteria in the LTCF setting, where these bacteria are increasingly becoming prevalent, are needed to help guide infection prevention and control. Improvements are required to develop outputs of sufficient quality to help guide interventions and policy in the future. We suggest a checklist of criteria to be used as a practical guide to determine whether a model is robust enough to test policy. Infect Control Hosp Epidemiol 2017;38:216-225.

  4. Predictive and mechanistic multivariate linear regression models for reaction development

    PubMed Central

    Santiago, Celine B.; Guo, Jing-Yao

    2018-01-01

    Multivariate Linear Regression (MLR) models utilizing computationally-derived and empirically-derived physical organic molecular descriptors are described in this review. Several reports demonstrating the effectiveness of this methodological approach towards reaction optimization and mechanistic interrogation are discussed. A detailed protocol to access quantitative and predictive MLR models is provided as a guide for model development and parameter analysis. PMID:29719711

  5. Bifurcation analysis in SIR epidemic model with treatment

    NASA Astrophysics Data System (ADS)

    Balamuralitharan, S.; Radha, M.

    2018-04-01

    We investigated the bifurcation analysis of nonlinear system of SIR epidemic model with treatment. It is accepted that the treatment is corresponding to the quantity of infective which is below the limit and steady when the quantity of infective achieves the limit. We analyze about the Transcritical bifurcation which occurs at the disease free equilibrium point and Hopf bifurcation which occurs at endemic equilibrium point. Using MATLAB we show the picture of bifurcation at the disease free equilibrium point.

  6. Analysis of Three-dimension Viscous Flow in the Model Axial Compressor Stage K1002L

    NASA Astrophysics Data System (ADS)

    Tribunskaia, K.; Kozhukhov, Y. V.

    2017-08-01

    The main investigation subject considered in this paper is axial compressor model stage K1002L. Three simulation models were designed: Scheme 1 - inlet stage model consisting of IGV (Inlet Guide Vane), rotor and diffuser; Scheme 2 - two-stage model: IGV, first-stage rotor, first-stage diffuser, second-stage rotor, EGV (Exit Guide Vane); Scheme 3 - full-round model: IGV, rotor, diffuser. Numerical investigation of the model stage was held for four circumferential velocities at the outer diameter (Uout=125,160,180,210 m/s) within the range of flow coefficient: ϕ = 0.4 - 0.6. The computational domain was created with ANSYS CFX Workbench. According to simulation results, there were constructed aerodynamic characteristic curves of adiabatic efficiency and the adiabatic head coefficient calculated for total parameters were compared with data from the full-scale test received at the Central Boiler and Turbine Institution (CBTI), thus, verification of the calculated data was carried out. Moreover, there were conducted the following studies: comparison of aerodynamic characteristics of the schemes 1, 2; comparison of the sector and full-round models. The analysis and conclusions are supplemented by gas-dynamic method calculation for axial compressor stages.

  7. Assessing Ion-Water Interactions in the AMOEBA Force Field Using Energy Decomposition Analysis of Electronic Structure Calculations.

    PubMed

    Mao, Yuezhi; Demerdash, Omar; Head-Gordon, Martin; Head-Gordon, Teresa

    2016-11-08

    AMOEBA is a molecular mechanics force field that addresses some of the shortcomings of a fixed partial charge model, by including permanent atomic point multipoles through quadrupoles, as well as many-body polarization through the use of point inducible dipoles. In this work, we investigate how well AMOEBA formulates its non-bonded interactions, and how it implicitly incorporates quantum mechanical effects such as charge penetration (CP) and charge transfer (CT), for water-water and water-ion interactions. We find that AMOEBA's total interaction energies, as a function of distance and over angular scans for the water dimer and for a range of water-monovalent cations, agree well with an advanced density functional theory (DFT) model, whereas the water-halides and water-divalent cations show significant disagreement with the DFT result, especially in the compressed region when the two fragments overlap. We use a second-generation energy decomposition analysis (EDA) scheme based on absolutely localized molecular orbitals (ALMOs) to show that in the best cases AMOEBA relies on cancellation of errors by softening of the van der Waals (vdW) wall to balance permanent electrostatics that are too unfavorable, thereby compensating for the missing CP effect. CT, as another important stabilizing effect not explicitly taken into account in AMOEBA, is also found to be incorporated by the softened vdW interaction. For the water-halides and water-divalent cations, this compensatory approach is not as well executed by AMOEBA over all distances and angles, wherein permanent electrostatics remains too unfavorable and polarization is overdamped in the former while overestimated in the latter. We conclude that the DFT-based EDA approach can help refine a next-generation AMOEBA model that either realizes a better cancellation of errors for problematic cases like those illustrated here, or serves to guide the parametrization of explicit functional forms for short-range contributions from CP and/or CT.

  8. A Peep into the Uncertainty-Complexity-Relevance Modeling Trilemma through Global Sensitivity and Uncertainty Analysis

    NASA Astrophysics Data System (ADS)

    Munoz-Carpena, R.; Muller, S. J.; Chu, M.; Kiker, G. A.; Perz, S. G.

    2014-12-01

    Model Model complexity resulting from the need to integrate environmental system components cannot be understated. In particular, additional emphasis is urgently needed on rational approaches to guide decision making through uncertainties surrounding the integrated system across decision-relevant scales. However, in spite of the difficulties that the consideration of modeling uncertainty represent for the decision process, it should not be avoided or the value and science behind the models will be undermined. These two issues; i.e., the need for coupled models that can answer the pertinent questions and the need for models that do so with sufficient certainty, are the key indicators of a model's relevance. Model relevance is inextricably linked with model complexity. Although model complexity has advanced greatly in recent years there has been little work to rigorously characterize the threshold of relevance in integrated and complex models. Formally assessing the relevance of the model in the face of increasing complexity would be valuable because there is growing unease among developers and users of complex models about the cumulative effects of various sources of uncertainty on model outputs. In particular, this issue has prompted doubt over whether the considerable effort going into further elaborating complex models will in fact yield the expected payback. New approaches have been proposed recently to evaluate the uncertainty-complexity-relevance modeling trilemma (Muller, Muñoz-Carpena and Kiker, 2011) by incorporating state-of-the-art global sensitivity and uncertainty analysis (GSA/UA) in every step of the model development so as to quantify not only the uncertainty introduced by the addition of new environmental components, but the effect that these new components have over existing components (interactions, non-linear responses). Outputs from the analysis can also be used to quantify system resilience (stability, alternative states, thresholds or tipping points) in the face of environmental and anthropogenic change (Perz, Muñoz-Carpena, Kiker and Holt, 2013), and through MonteCarlo mapping potential management activities over the most important factors or processes to influence the system towards behavioral (desirable) outcomes (Chu-Agor, Muñoz-Carpena et al., 2012).

  9. Adherence predictors in an Internet-based Intervention program for depression.

    PubMed

    Castro, Adoración; López-Del-Hoyo, Yolanda; Peake, Christian; Mayoral, Fermín; Botella, Cristina; García-Campayo, Javier; Baños, Rosa María; Nogueira-Arjona, Raquel; Roca, Miquel; Gili, Margalida

    2018-05-01

    Internet-delivered psychotherapy has been demonstrated to be effective in the treatment of depression. Nevertheless, the study of the adherence in this type of the treatment reported divergent results. The main objective of this study is to analyze predictors of adherence in a primary care Internet-based intervention for depression in Spain. A multi-center, three arm, parallel, randomized controlled trial was conducted with 194 depressive patients, who were allocated in self-guided or supported-guided intervention. Sociodemographic and clinical characteristics were gathered using a case report form. The Mini international neuropsychiatric interview diagnoses major depression. Beck Depression Inventory was used to assess depression severity. The visual analogic scale assesses the respondent's self-rated health and Short Form Health Survey was used to measure the health-related quality of life. Age results a predictor variable for both intervention groups (with and without therapist support). Perceived health is a negative predictor of adherence for the self-guided intervention when change in depression severity was included in the model. Change in depression severity results a predictor of adherence in the support-guided intervention. Our findings demonstrate that in our sample, there are differences in sociodemographic and clinical variables between active and dropout participants and we provide adherence predictors in each intervention condition of this Internet-based program for depression (self-guided and support-guided). It is important to point that further research in this area is essential to improve tailored interventions and to know specific patients groups can benefit from these interventions.

  10. [Clinical treatment of children and adolescents with gender dysphoria from international experts' point of view].

    PubMed

    Rutzen, Katharina M; Nieder, Timo Ole; Schreier, Herbert; Möller, Birgit

    2014-01-01

    The clinical treatment of children and adolescents with gender dysphoria is still a controversial issue. The aim of this study was to get an overview of the knowledge and experience of international experts and to highlight shared views as well as differences in theoretical convictions and treatment approaches. Half-structured, guide-line based interviews were carried out with international experts in the field. The interviews were analyzed using qualitative content analysis (Mayring, 2010).

  11. A computed tomographic anatomical study of the upper sacrum. Application for a user guide of pelvic fixation with iliosacral screws in adult spinal deformity.

    PubMed

    Dubory, Arnaud; Bouloussa, Houssam; Riouallon, Guillaume; Wolff, Stéphane

    2017-12-01

    Widely used in traumatic pelvic ring fractures, the iliosacral (IS) screw technique for spino-pelvic fixation remains anecdotal in adult spinal deformity. The objective of this study was to assess anatomical variability of the adult upper sacrum and to provide a user guide of spino-pelvic fixation with IS screws in adult spinal deformity. Anatomical variability of the upper sacrum according to age, gender, height and weight was sought on 30 consecutive pelvic CT-scans. Thus, a user guide of spino-pelvic fixation with IS screws was modeled and assessed on ten CT-scans as described below. Two invariable landmarks usable during the surgical procedure were defined: point A (corresponding to the connector binding the IS screw to the spinal rod), equidistant from the first posterior sacral hole and the base of the S1 articular facet and 10 mm-embedded into the sacrum; point B (corresponding to the tip of the IS screw) located at the junction of the anterior third and middle third of the sacral endplate in the sagittal plane and at the middle of the endplate in the coronal plane. Point C corresponded to the intersection between the A-B direction and the external facet of the iliac wing. Three-dimensional reconstructions modeling the IS screw optimal direction according to the A-B-C straight line were assessed. Age had no effect on the anatomy of the upper sacrum. The distance between the base of the S1 superior articular facet and the top of the first posterior sacral hole was correlated with weight (r = 0.6; 95% CI [0.6-0.9]); p < 0.001). Sacral end-plate thickness increased for male patients (p < 0.001) and was strongly correlated with height (r = 0.6; 95% CI [0.29-0.75]); p < 0.001) and weight (r = 0.8; 95% CI [0.6-0.9]); p < 0.001). The thickness of the inferior part of the S1 vertebral body increased in male patients (p < 0.001). Other measured parameters slightly varied according to gender, height and weight. Simulating the described technique of pelvic fixation, no misplaced IS screw was found whatever the age, gender and morphologic parameters. This user guide of spinopelvic fixation with IS screws seems to be reliable and reproducible independently of age, gender and morphologic characteristics but needs clinical assessment. Level IV.

  12. Validation of the Children's Hospital of Philadelphia Retinopathy of Prematurity (CHOP ROP) Model.

    PubMed

    Binenbaum, Gil; Ying, Gui-Shuang; Tomlinson, Lauren A

    2017-08-01

    The Children's Hospital of Philadelphia Retinopathy of Prematurity (CHOP ROP) model uses birth weight (BW), gestational age at birth (GA), and weight gain rate to predict the risk of severe retinopathy of prematurity (ROP). In a model development study, it predicted all infants requiring treatment, while greatly reducing the number of examinations compared with current screening guidelines. To validate the CHOP ROP model in a multicenter cohort that is large enough to obtain a precise estimate of the model's sensitivity for treatment-requiring ROP. This investigation was a secondary analysis of data from the Postnatal Growth and Retinopathy of Prematurity (G-ROP) Study. The setting was 30 hospitals in the United States and Canada between January 1, 2006, and June 30, 2012. The dates of analysis were September 28 to October 5, 2015. Participants were premature infants at risk for ROP with a known ROP outcome. Sensitivity for Early Treatment of Retinopathy of Prematurity type 1 ROP and potential reduction in the number of infants requiring examinations. In the primary analysis, the CHOP ROP model was applied weekly to predict the risk of ROP. If the risk was above a cut-point level (high risk), examinations were indicated, while low-risk infants received no examinations. In a secondary analysis, low-risk infants received fewer examinations rather than no examinations. Participants included 7483 premature infants at risk for ROP with a known ROP outcome. Their median BW was 1070 g (range, 310-3000 g), and their median GA was 28 weeks (range, 22-35 weeks). Among them, 3575 (47.8%) were female, and their race/ethnicity was 3615 white (48.3%), 2310 black (30.9%), 233 Asian (3.1%), 93 Pacific Islander (1.2%), and 40 American Indian/Alaskan native (0.5%). The original CHOP ROP model correctly predicted 452 of 459 infants who developed type 1 ROP (sensitivity, 98.5%; 95% CI, 96.9%-99.3%), reducing the number of infants requiring examinations by 34.3% if only high-risk infants received examinations. Lowering the cut point to capture all type 1 ROP cases (sensitivity, 100%; 95% CI, 99.2%-100%) resulted in only 6.8% of infants not requiring examinations. However, if low-risk infants were examined at 37 weeks' postmenstrual age and followed up only if ROP was present at that examination, all type 1 ROP cases would be captured, and the number of examinations performed among infants with GA exceeding 27 weeks would be reduced by 28.4%. The CHOP ROP model demonstrated high but not 100% sensitivity and may be better used to reduce examination frequency. The model might be used reliably to guide a modified ROP screening schedule and decrease the number of examinations performed.

  13. Large Scale Ice Water Path and 3-D Ice Water Content

    DOE Data Explorer

    Liu, Guosheng

    2008-01-15

    Cloud ice water concentration is one of the most important, yet poorly observed, cloud properties. Developing physical parameterizations used in general circulation models through single-column modeling is one of the key foci of the ARM program. In addition to the vertical profiles of temperature, water vapor and condensed water at the model grids, large-scale horizontal advective tendencies of these variables are also required as forcing terms in the single-column models. Observed horizontal advection of condensed water has not been available because the radar/lidar/radiometer observations at the ARM site are single-point measurement, therefore, do not provide horizontal distribution of condensed water. The intention of this product is to provide large-scale distribution of cloud ice water by merging available surface and satellite measurements. The satellite cloud ice water algorithm uses ARM ground-based measurements as baseline, produces datasets for 3-D cloud ice water distributions in a 10 deg x 10 deg area near ARM site. The approach of the study is to expand a (surface) point measurement to an (satellite) areal measurement. That is, this study takes the advantage of the high quality cloud measurements at the point of ARM site. We use the cloud characteristics derived from the point measurement to guide/constrain satellite retrieval, then use the satellite algorithm to derive the cloud ice water distributions within an area, i.e., 10 deg x 10 deg centered at ARM site.

  14. Using Bayes' theorem for free energy calculations

    NASA Astrophysics Data System (ADS)

    Rogers, David M.

    Statistical mechanics is fundamentally based on calculating the probabilities of molecular-scale events. Although Bayes' theorem has generally been recognized as providing key guiding principals for setup and analysis of statistical experiments [83], classical frequentist models still predominate in the world of computational experimentation. As a starting point for widespread application of Bayesian methods in statistical mechanics, we investigate the central quantity of free energies from this perspective. This dissertation thus reviews the basics of Bayes' view of probability theory, and the maximum entropy formulation of statistical mechanics before providing examples of its application to several advanced research areas. We first apply Bayes' theorem to a multinomial counting problem in order to determine inner shell and hard sphere solvation free energy components of Quasi-Chemical Theory [140]. We proceed to consider the general problem of free energy calculations from samples of interaction energy distributions. From there, we turn to spline-based estimation of the potential of mean force [142], and empirical modeling of observed dynamics using integrator matching. The results of this research are expected to advance the state of the art in coarse-graining methods, as they allow a systematic connection from high-resolution (atomic) to low-resolution (coarse) structure and dynamics. In total, our work on these problems constitutes a critical starting point for further application of Bayes' theorem in all areas of statistical mechanics. It is hoped that the understanding so gained will allow for improvements in comparisons between theory and experiment.

  15. Developing the Model of "Pedagogical Art Communication" Using Social Phenomenological Analysis: An Introduction to a Research Method and an Example for Its Outcome

    ERIC Educational Resources Information Center

    Hofmann, Fabian

    2016-01-01

    Social phenomenological analysis is presented as a research method for museum and art education. After explaining its methodological background, it is shown how this method has been applied in a study of gallery talks or guided tours in art museums: Analyzing the situation by description and interpretation, a model for understanding gallery talks…

  16. Content analysis to locate assistive technology in Queensland's motor injury insurance rehabilitation legislation and guidelines.

    PubMed

    Steel, Emily J

    2018-06-08

    Reforms to Australia's disability and rehabilitation sectors have espoused the potential of assistive technology as an enabler. As new insurance systems are being developed it is timely to examine the structure of existing systems. This exploratory study examined the policies guiding assistive technology provision in the motor accident insurance sector of one Australian state. Policy documents were analyzed iteratively with set of qualitative questions to understand the intent and interpretation of policies guiding assistive technology provision. Content analysis identified relevant sections and meaningful terminology, and context analysis explored the dominant perspectives informing policy. The concepts and language of assistive technology are not part of the policy frameworks guiding rehabilitation practice in Queensland's motor accident insurance sector. The definition of rehabilitation in the legislation is consistent contemporary international interpretations that focus on optimizing functioning in interaction with the environment. However, the supporting documents are focused on recovery from injuries where decisions are guided by clinical need and affordability. The policies frame rehabilitation in a medical model that assistive technology provision from the rehabilitation plan. The legislative framework provides opportunities to develop and improve assistive technology provision as part of an integrated approach to rehabilitation.

  17. Atlas instrumentation guided by the medial edge of the posterior arch: An anatomic and radiologic study.

    PubMed

    Al-Habib, Amro F; Al-Rabie, Abdulkarim; Aleissa, Sami; Albakr, Abdulrahman; Abobotain, Abdulaziz

    2017-01-01

    This was an interventional human cadaver study and radiological study. Atlas instrumentation is frequently involved in fusion procedures involving the craniocervical junction area. Identification of the entry point at the center of atlas lateral mass (ALM) is challenging because of its rounded posterior surface and the surrounding venous plexus. This report examines using the medial edge of atlas posterior arch (MEC1) as a fixed and reliable anatomic reference to guide the entry point of ALM screws. Fifty, normal, cervical spine computed tomography studies were reviewed. ALM screw trajectories were planned at one point along MEC1 and another point 2 mm lateral to MEC1. Free-hand ALM instrumentation was performed in ten fresh human cadavers using the 2 mm entry point, with a sagittal trajectory parallel to atlas inferior arch (IAC1); three-dimensional imaging was then performed to confirm instrumentation accuracy. The average ALM diameter was 12.35 mm. Inserting a screw using the entry point 2 mm lateral to MEC1 was closer to ALM midpoint than using the entry point along MEC1 ( P < 0.0001). Twenty ALM screws were successfully inserted in the ten cadavers. No encroachments into the spinal canal or foramen transversarium occurred. However, two screws were superiorly directed and violated the occipitocervical joint; they were not parallel to IAC1. MEC1 provides a fixed and reliable landmark for ALM instrumentation. An entry point 2 mm point lateral to MEC1 is close to ALM midpoint. IAC1 also provides a guide for the sagittal trajectory. Attention to anatomic landmarks may help reduce complications associated with atlas instrumentation but should be verified in future clinical studies.

  18. Combined cumulative sum (CUSUM) and chronological environmental analysis as a tool to improve the learning environment for linear-probe endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) trainees: a pilot study.

    PubMed

    Norisue, Yasuhiro; Tokuda, Yasuharu; Juarez, Mayrol; Uchimido, Ryo; Fujitani, Shigeki; Stoeckel, David A

    2017-02-07

    Cumulative sum (CUSUM) analysis can be used to continuously monitor the performance of an individual or process and detect deviations from a preset or standard level of achievement. However, no previous study has evaluated the utility of CUSUM analysis in facilitating timely environmental assessment and interventions to improve performance of linear-probe endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). The aim of this study was to evaluate the usefulness of combined CUSUM and chronological environmental analysis as a tool to improve the learning environment for EBUS-TBNA trainees. This study was an observational chart review. To determine if performance was acceptable, CUSUM analysis was used to track procedural outcomes of trainees in EBUS-TBNA. To investigate chronological changes in the learning environment, multivariate logistic regression analysis was used to compare several indices before and after time points when significant changes occurred in proficiency. Presence of an additional attending bronchoscopist was inversely associated with nonproficiency (odds ratio, 0.117; 95% confidence interval, 0-0.749; P = 0.019). Other factors, including presence of an on-site cytopathologist and dose of sedatives used, were not significantly associated with duration of nonproficiency. Combined CUSUM and chronological environmental analysis may be useful in hastening interventions that improve performance of EBUS-TBNA.

  19. Heliport Noise Model (HNM). Version 1. (User’s Guide)

    DTIC Science & Technology

    1988-02-01

    Examples of acoustically hard surfaces include concrete or asphalt paving, water or baked clay surfaces. Mote that if the site does not meet the...neighbor should be characterized as either Hard (H) or Soft (S). From an acoustic point of view, "hard" ground is either pavement or water . All other...GROUND DISraNCE 10 - MAP - SEIUP 11 - HELIPADS 3 - HELIPADS 12- rAKEOI tRACKS 4 - HELICOPrERS 13 - APPROACH IRACKS 5 - IAKt-OFFS 14- rAxx fRACKS C6

  20. Defect-free atomic array formation using the Hungarian matching algorithm

    NASA Astrophysics Data System (ADS)

    Lee, Woojun; Kim, Hyosub; Ahn, Jaewook

    2017-05-01

    Deterministic loading of single atoms onto arbitrary two-dimensional lattice points has recently been demonstrated, where by dynamically controlling the optical-dipole potential, atoms from a probabilistically loaded lattice were relocated to target lattice points to form a zero-entropy atomic lattice. In this atom rearrangement, how to pair atoms with the target sites is a combinatorial optimization problem: brute-force methods search all possible combinations so the process is slow, while heuristic methods are time efficient but optimal solutions are not guaranteed. Here, we use the Hungarian matching algorithm as a fast and rigorous alternative to this problem of defect-free atomic lattice formation. Our approach utilizes an optimization cost function that restricts collision-free guiding paths so that atom loss due to collision is minimized during rearrangement. Experiments were performed with cold rubidium atoms that were trapped and guided with holographically controlled optical-dipole traps. The result of atom relocation from a partially filled 7 ×7 lattice to a 3 ×3 target lattice strongly agrees with the theoretical analysis: using the Hungarian algorithm minimizes the collisional and trespassing paths and results in improved performance, with over 50% higher success probability than the heuristic shortest-move method.

Top