Sample records for h2 breath test

  1. [Analysis of breath hydrogen (H2) in diagnosis of gastrointestinal function: validation of a pocket breath H2 test analyzer].

    PubMed

    Braden, B; Braden, C P; Klutz, M; Lembcke, B

    1993-04-01

    Breath hydrogen (H2) analysis, as used in gastroenterologic function tests, requires a stationary analysis system equipped with a gaschromatograph or an electrochemical sensor cell. Now a portable breath H2-analyzer has been miniaturized to pocket size (104 mm x 62 mm x 29 mm). The application of this device in clinical practice has been assessed in comparison to the standard GMI-exhaled monitor. The pocket analyzer showed a linear response to standards with H2-concentrations ranging from 0-100 ppm (n = 7), which was not different from the GMI-apparatus. The correlation of both methods during clinical application (lactose tolerance tests, mouth-to-coecum transit time determined with lactulose) was excellent (Y = 1.08 X + 0.96; r = 0.959). Using the new device, both, analysis (3 s vs. 90 s) and the reset-time (43 s vs. 140 s) were shorter whereas calibration was more feasible with the GMI-apparatus. It is concluded, that the considerably cheaper pocket-sized breath H2-analyzer is as precise and sensitive as the GMI-exhaled monitor, and thus presents a valid alternative for H2-breath tests.

  2. Follow-up of coeliac disease with the novel one-hour 13C-sorbitol breath test versus the H2-sorbitol breath test.

    PubMed

    Tveito, Kari; Hetta, Anne Kristine; Askedal, Mia; Brunborg, Cathrine; Sandvik, Leiv; Løberg, Else Marit; Skar, Viggo

    2011-07-01

    We recently developed a (13)C-sorbitol breath test ((13)C-SBT) as an alternative to the H(2)-sorbitol breath test (H(2)-SBT) for coeliac disease. In this study we compared the diagnostic properties of the H(2)-SBT and the (13)C-SBT in follow-up of coeliac disease. Twenty-seven coeliac patients on a gluten-free diet (GFD) performed the breath tests. All had been tested before treatment in the initial study of the (13)C-SBT, in which 39 untreated coeliac patients, 40 patient controls, and 26 healthy volunteers participated. Five gram sorbitol and 100 mg (13)C-sorbitol were dissolved in 250 ml tap water and given orally. H(2), CH(4) and (13)CO(2) were measured in end-expiratory breath samples every 30 min for 4 h. Increased H(2) concentration ≥20 ppm from basal values was used as cut-off for the H(2)-SBT. Sixty minutes values were used as diagnostic index in the (13)C-SBT. (13)CO(2) levels at 60 min increased in 20/26 treated coeliac patients (77%) after GFD, but were significantly lower than in control groups. Out of 20 patients who had a positive H(2)-SBT before GFD, 12 had a negative H(2)-SBT after GFD. Peak H(2) concentrations were not correlated with (13)C-SBT results. The study confirms the sensitivity of a one-hour (13)C-SBT for small intestinal malabsorption. The (13)C-SBT has superior diagnostic properties compared with the H(2)-SBT in follow-up of coeliac disease.

  3. Additional Value of CH4 Measurement in a Combined 13C/H2 Lactose Malabsorption Breath Test: A Retrospective Analysis

    PubMed Central

    Houben, Els; De Preter, Vicky; Billen, Jaak; Van Ranst, Marc; Verbeke, Kristin

    2015-01-01

    The lactose hydrogen breath test is a commonly used, non-invasive method for the detection of lactose malabsorption and is based on an abnormal increase in breath hydrogen (H2) excretion after an oral dose of lactose. We use a combined 13C/H2 lactose breath test that measures breath 13CO2 as a measure of lactose digestion in addition to H2 and that has a better sensitivity and specificity than the standard test. The present retrospective study evaluated the results of 1051 13C/H2 lactose breath tests to assess the impact on the diagnostic accuracy of measuring breath CH4 in addition to H2 and 13CO2. Based on the 13C/H2 breath test, 314 patients were diagnosed with lactase deficiency, 138 with lactose malabsorption or small bowel bacterial overgrowth (SIBO), and 599 with normal lactose digestion. Additional measurement of CH4 further improved the accuracy of the test as 16% subjects with normal lactose digestion and no H2-excretion were found to excrete CH4. These subjects should have been classified as subjects with lactose malabsorption or SIBO. In conclusion, measuring CH4-concentrations has an added value to the 13C/H2 breath test to identify methanogenic subjects with lactose malabsorption or SIBO. PMID:26371034

  4. Evaluation of 13CO2 breath tests for the detection of fructose malabsorption.

    PubMed

    Hoekstra, J H; van den Aker, J H; Kneepkens, C M; Stellaard, F; Geypens, B; Ghoos, Y F

    1996-03-01

    Breath hydrogen (H2) studies have made clear that small intestinal absorption of fructose is limited, especially in toddlers. Malabsorption of fructose may be a cause of recurrent abdominal pain and chronic nonspecific diarrhea (toddler's diarrhea). Fructose absorption is facilitated by equimolar doses of glucose and, as we have found, amino acids (especially L-alanine); the mechanism underlying this effect remains unclear. To study fructose absorption in a more direct way, we combined breath H2 studies with breath 13CO2 studies. Gastric emptying was studied by using L-glycine-1-13C in 4 children from 12.1 to 16.0 years of age. After 25 gm of fructose and 27.5 gm of glucose, when given together, gastric emptying was significantly (p<0.05) slower than with either sugar alone. In a second series of experiments, 5 children from 12.0 to 15.9 years of age were tested with 25 gm of fructose, alone and with equimolar doses of glucose and L-alanine, and 4 younger children from 3.1 to 6.1 years of age were tested with 2 gm/kg (max 37.5 gm) fructose, alone or with an equimolar dose of L-alanine. All fructose solutions were enriched with 15 mg of D-fructose-13C-6. In all 9 children, fructose was malabsorbed as judged by breath H2 increases > or = 20 ppm, and the addition of glucose or L-alanine resulted in significantly lower breath H2 increases (p < or = 0.005 for glucose, p < or = 0.001 for alanine). In contrast, the addition of alanine or glucose did not change the pattern of breath 13CO2 excretion in the 5 older children, whereas in the 4 younger children (with relatively higher doses), L-alanine addition resulted in significantly lower increases in breath 13CO2. In the latter group, for each time point, breath H2 and 13CO2 concentrations after fructose were compared with those after fructose plus L-alanine; in 20 out of 24 points, both H2 and 13CO2 were higher after fructose. These results suggest that 13CO2 not only originated from the oxidation of absorbed substrate

  5. An optimized 13C-urea breath test for the diagnosis of H pylori infection

    PubMed Central

    Campuzano-Maya, Germán

    2007-01-01

    AIM: To validate an optimized 13C-urea breath test (13C-UBT) protocol for the diagnosis of H pylori infection that is cost-efficient and maintains excellent diagnostic accuracy. METHODS: 70 healthy volunteers were tested with two simplified 13C-UBT protocols, with test meal (Protocol 2) and without test meal (Protocol 1). Breath samples were collected at 10, 20 and 30 min after ingestion of 50 mg 13C-urea dissolved in 10 mL of water, taken as a single swallow, followed by 200 mL of water (pH 6.0) and a circular motion around the waistline to homogenize the urea solution. Performance of both protocols was analyzed at various cut-off values. Results were validated against the European protocol. RESULTS: According to the reference protocol, 65.7% individuals were positive for H pylori infection and 34.3% were negative. There were no significant differences in the ability of both protocols to correctly identify positive and negative H pylori individuals. However, only Protocol 1 with no test meal achieved accuracy, sensitivity, specificity, positive and negative predictive values of 100%. The highest values achieved by Protocol 2 were 98.57%, 97.83%, 100%, 100% and 100%, respectively. CONCLUSION: A 10 min, 50 mg 13C-UBT with no test meal using a cut-off value of 2-2.5 is a highly accurate test for the diagnosis of H pylori infection at a reduced cost. PMID:17907288

  6. Tests for H. pylori

    MedlinePlus

    Peptic ulcer disease - H. pylori ; PUD - H. pylori ... There are several methods to test for H. pylori infection. Breath Test (Carbon Isotope-urea Breath Test, or UBT) Up to 2 weeks before the test, you need to stop taking ...

  7. Evaluation of H2O2 and pH in exhaled breath condensate samples: methodical and physiological aspects.

    PubMed

    Knobloch, Henri; Becher, Gunther; Decker, Manfred; Reinhold, Petra

    2008-05-01

    This veterinary study is aimed at further standardization of H(2)O(2) and pH measurements in exhaled breath condensate (EBC). Data obtained in the study provide valuable information for many mammalian species including humans, and may help to avoid general pitfalls in interpretation of EBC data. EBC was sampled via the 'ECoScreen' in healthy calves (body weight 63-98 kg). Serum samples and condensates of ambient (indoor) air were collected in parallel. In the study on H(2)O(2), concentrations of H(2)O(2) in EBC, blood and ambient air were determined with the biosensor system 'ECoCheck'. In EBC, the concentration of H(2)O(2) was found to be dependent on food intake and increased significantly in the course of the day. Physiologically, lowest H(2)O(2) concentrations at 06:00 varied within the range 138-624 nmol l(-1) EBC or 0.10-0.94 nmol per 100 l exhaled breath and individual concentrations were significantly different indicating a remarkable intersubject variability. Highly reproducible results were seen within each subject (three different days within 4 weeks). No correlation existed between H(2)O(2) concentrations in EBC and blood, and EBC-H(2)O(2) was not influenced by variables of spontaneous breathing. Further results confirmed that standardization of H(2)O(2) measurements in EBC requires (1) the re-calculation of the concentration exhaled per 100 l exhaled breath (because the analyzed concentration in the liquid condensate underlies multiple methodological sources of variability given by the collection process), and (2) subtracting the concentration of inspired indoor H(2)O(2). In the study on pH use of the ISFET electrode (Sentron, the Netherlands) and a blood gas analyzer ABL 550 (Radiometer, Denmark) led to comparable results for EBC-pH (r=0.89, R(2)=79.3%, pH data in non-degassed EBC samples varied between 5.3 and 6.5, and were not significantly different between subjects, but were significantly higher in the evening compared

  8. Fabry-Perot microcavity sensor for H2-breath-test analysis

    NASA Astrophysics Data System (ADS)

    Vincenti, Maria Antonietta; De Sario, Marco; Petruzzelli, V.; D'Orazio, Antonella; Prudenzano, Francesco; de Ceglia, Domenico; Scalora, Michael

    2007-10-01

    Leak detection of hydrogen for medical purposes, based on the monitoring of the optical response of a simple Fabry-Perot microcavity, is proposed to investigate either the occurrence of lactose intolerance, or lactose malabsorption condition. Both pathologic conditions result in bacterial overgrowth in the intestine, which causes increased spontaneous emission of H2 in the human breath. Two sensitivity figures of merit are introduced to inspect changes in the sensor response, and to relate the microcavity response to a pathologic condition, which is strictly related to a different level of exhaled hydrogen. Different sensor configurations using a metal-dielectric microcavity are reported and discussed in order to make the most of the well-known ability of palladium to spontaneously absorb hydrogen.

  9. Estimation of gastric pH in cynomolgus monkeys, rats, and dogs using [(13)C]-calcium carbonate breath test.

    PubMed

    Tobita, Kazuki; Inada, Makoto; Sato, Asuka; Sudoh, Kimiyoshi; Sato, Hitoshi

    2016-09-01

    The determination of gastric pH is important for the confirmation of efficacy of anti-secretory drugs. However, current methods for measurement of gastric pH provide significant stress to animals and humans. The objective of this study is to establish an easy and reliable gastric pH measurement method by determining (13)CO2 concentration in expired air of monkeys, dogs, and rats after oral administration of Ca(13)CO3. A correlation of (13)CO2 concentration determined by a Ca(13)CO3 breath test with gastric pH just before Ca(13)CO3 administration was analyzed in the 3 animal species. The equations and contribution ratios of regression line were calculated from logarithmic (13)CO2 concentrations at 15min after administration of Ca(13)CO3 using the linear regression analysis. The (13)CO2 concentration in the Ca(13)CO3 breath test was well correlated with the gastric pH just before Ca(13)CO3 administration in the 3 animal species (r=-0.977 to -0.952). The equations of regression line between the (13)CO2 concentration and the gastric pH in each animal species showed good contribution ratios (R(2)≥0.89). The Ca(13)CO3 breath test is an informative tool to estimate gastric pH in animals and will be applicable as a new noninvasive tool for patients with GERD/PPI-resistant symptoms. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  10. [Application of the breath hydrogen test in gastroenterology].

    PubMed

    Loranskaia, I D; Panina, N A; Zheltakova, O V

    2006-01-01

    The diagnostic capacities of the breath hydrogen test in gastroenterology are discussed in the article. The authors describe the results of their own research--determination of the intestinal bacterial contamination in patients with chronic biliary pancreatitis with the help of the Micro H2 breath hydrogen analyzer.

  11. Breath tests and irritable bowel syndrome

    PubMed Central

    Rana, Satya Vati; Malik, Aastha

    2014-01-01

    Breath tests are non-invasive tests and can detect H2 and CH4 gases which are produced by bacterial fermentation of unabsorbed intestinal carbohydrate and are excreted in the breath. These tests are used in the diagnosis of carbohydrate malabsorption, small intestinal bacterial overgrowth, and for measuring the orocecal transit time. Malabsorption of carbohydrates is a key trigger of irritable bowel syndrome (IBS)-type symptoms such as diarrhea and/or constipation, bloating, excess flatulence, headaches and lack of energy. Abdominal bloating is a common nonspecific symptom which can negatively impact quality of life. It may reflect dietary imbalance, such as excess fiber intake, or may be a manifestation of IBS. However, bloating may also represent small intestinal bacterial overgrowth. Patients with persistent symptoms of abdominal bloating and distension despite dietary interventions should be referred for H2 breath testing to determine the presence or absence of bacterial overgrowth. If bacterial overgrowth is identified, patients are typically treated with antibiotics. Evaluation of IBS generally includes testing of other disorders that cause similar symptoms. Carbohydrate malabsorption (lactose, fructose, sorbitol) can cause abdominal fullness, bloating, nausea, abdominal pain, flatulence, and diarrhea, which are similar to the symptoms of IBS. However, it is unclear if these digestive disorders contribute to or cause the symptoms of IBS. Research studies show that a proper diagnosis and effective dietary intervention significantly reduces the severity and frequency of gastrointestinal symptoms in IBS. Thus, diagnosis of malabsorption of these carbohydrates in IBS using a breath test is very important to guide the clinician in the proper treatment of IBS patients. PMID:24976698

  12. Hydrogen breath test in schoolchildren.

    PubMed Central

    Douwes, A C; Schaap, C; van der Klei-van Moorsel, J M

    1985-01-01

    The frequency of negative hydrogen breath tests due to colonic bacterial flora which are unable to produce hydrogen was determined after oral lactulose challenge in 98 healthy Dutch schoolchildren. There was a negative result in 9.2%. The probability of a false normal lactose breath test (1:77) was calculated from these results together with those from a separate group of children with lactose malabsorption (also determined by hydrogen breath test). A study of siblings and mothers of subjects with a negative breath test did not show familial clustering of this condition. Faecal incubation tests with various sugars showed an increase in breath hydrogen greater than 100 parts per million in those with a positive breath test while subjects with a negative breath test also had a negative faecal incubation test. The frequency of a false negative hydrogen breath test was higher than previously reported, but this does not affect the superiority of this method of testing over the conventional blood glucose determination. PMID:4004310

  13. Data Mining Techniques Applied to Hydrogen Lactose Breath Test.

    PubMed

    Rubio-Escudero, Cristina; Valverde-Fernández, Justo; Nepomuceno-Chamorro, Isabel; Pontes-Balanza, Beatriz; Hernández-Mendoza, Yoedusvany; Rodríguez-Herrera, Alfonso

    2017-01-01

    Analyze a set of data of hydrogen breath tests by use of data mining tools. Identify new patterns of H2 production. Hydrogen breath tests data sets as well as k-means clustering as the data mining technique to a dataset of 2571 patients. Six different patterns have been extracted upon analysis of the hydrogen breath test data. We have also shown the relevance of each of the samples taken throughout the test. Analysis of the hydrogen breath test data sets using data mining techniques has identified new patterns of hydrogen generation upon lactose absorption. We can see the potential of application of data mining techniques to clinical data sets. These results offer promising data for future research on the relations between gut microbiota produced hydrogen and its link to clinical symptoms.

  14. [Detection of Helicobacter pylori by culture and the 13C-urea breath test using an automated breath 13C analyzer].

    PubMed

    Yamamoto, Y; Kouda, M; Abe, K; Sakurabayashi, S; Sezai, S; Hirano, M; Oka, H

    1995-11-01

    Up to now, the diagnosis of H. pylori infection has been made by the breath test using 13C-urea. In this study, 13C-urea breath samples were tested in 34 patients (peptic ulcer scar 17, chronic gastritis 17 cases) with an automated breath 13C analyzer (ABCA. Europa Scientific, Crewe, UK) and compared with the results of endoscopical diagnosis for H. pylori infection. Endoscopic and 13C-urea breath test (13C-UBT) were performed before eradicative medication. We described a modified protocol for the growth grade of H. pylori colonies in microbiology (H. pylori score), and for the delta 13C area under curve (AUC; permil*hr) obtained from each sample of expired breath. There was a significant correlation between delta 13C-AUC and the delta 13C level of each sample, but the correlation coefficient obtained at 10min (R2 = 0.582) was lower than that obtained at the other four time points (20min; 0.891, 30min; 0.949, 40min; 0.946, 50min; 0.946, 60min; 0.820). The delta 13C-AUC well correlated with H. pylori score (p < 0.01), none of 26 H. pylori positive patients detected by culture was 13C-UBT negative (delta 13C-AUC < 8.2 permil*hr in mean + 2SD of H. pylori negative group). In conclusion, 13C-UBT using ABCA has high sensitivity and specificity, and it provides a non-invasive method for the detection of H. pylori urease activity.

  15. sup 14 C-urea breath test for the detection of Helicobacter pylori

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veldhuyzen van Zanten, S.J.; Tytgat, K.M.; Hollingsworth, J.

    1990-04-01

    The high urease activity of Helicobacter pylori can be used to detect this bacterium by noninvasive breath tests. We have developed a {sup 14}C-urea breath test which uses 5 microCi {sup 14}C with 50 mg nonradioactive urea. Breath samples are collected at baseline and every 30 min for 2 h. Our study compared the outcome of the breath test to the results of histology and culture of endoscopically obtained gastric biopsies in 84 patients. The breath test discriminated well between the 50 positive patients and the 34 patients negative for Helicobacter pylori: the calculated sensitivity was 100%, specificity 88%, positivemore » predictive value 93%, and negative predictive value 100%. Treatment with bismuth subsalicylate and/or ampicillin resulted in lower counts of exhaled {sup 14}CO{sub 2} which correlated with histological improvement in gastritis. The {sup 14}C-urea breath test is a better gold standard for the detection of Helicobacter pylori than histology and/or culture.« less

  16. Exhaled breath condensate pH decreases following oral glucose tolerance test.

    PubMed

    Bikov, Andras; Pako, Judit; Montvai, David; Kovacs, Dorottya; Koller, Zsofia; Losonczy, Gyorgy; Horvath, Ildiko

    2015-12-15

    Exhaled breath condensate (EBC) pH is a widely measured non-invasive marker of airway acidity. However, some methodological aspects have not been thoroughly investigated. The aim of the study was to determine the effect of oral glucose tolerance test (OGTT) on EBC pH in attempt to better standardize its measurement. Seventeen healthy subjects (24  ±  2 years, 6 men, 11 women) participated in the study. EBC collection and capillary blood glucose measurements were performed before as well as 0, 30, 60 and 120 min after a standardized OGTT test. The rate of respiratory droplet dilution and pH were evaluated in EBC. Blood glucose significantly increased at 30 min and maintained elevation after 60 and 120 min following OGTT. Compared to baseline (7.99  ±  0.25) EBC pH significantly decreased immediately after OGTT (7.41  ±  0.47); this drop sustained over 30 (7.44  ±  0.72) and 60 min (7.62  ±  0.44) without a significant difference at 120 min (7.78  ±  0.26). No change was observed in the rate of respiratory droplet dilution. There was no relationship between blood glucose and EBC pH values. Sugar intake may significantly decrease EBC pH. This effect needs to be considered when performing EBC pH studies. Further experiments are also warranted to investigate the effect of diet on other exhaled biomarkers.

  17. Determination of breath acetone in 149 type 2 diabetic patients using a ringdown breath-acetone analyzer.

    PubMed

    Sun, Meixiu; Chen, Zhuying; Gong, Zhiyong; Zhao, Xiaomeng; Jiang, Chenyu; Yuan, Yuan; Wang, Zhennang; Li, Yingxin; Wang, Chuji

    2015-02-01

    Over 90% of diabetic patients have Type 2 diabetes. Although an elevated mean breath acetone concentration has been found to exist in Type 1 diabetes (T1D), information on breath acetone in Type 2 diabetes (T2D) has yet to be obtained. In this study, we first used gas chromatography-mass spectrometry (GC-MS) to validate a ringdown breath-acetone analyzer based on the cavity-ringdown-spectroscopy technique, through comparing breath acetone concentrations in the range 0.5-2.5 ppm measured using both methods. The linear fitting of R = 0.99 suggests that the acetone concentrations obtained using both methods are consistent with a largest standard deviation of ±0.4 ppm in the lowest concentration of the range. Next, 620 breath samples from 149 T2D patients and 42 healthy subjects were collected and tested using the breath analyzer. Four breath samples were taken from each subject under each of four different conditions: fasting, 2 h post-breakfast, 2 h post-lunch, and 2 h post-dinner. Simultaneous blood glucose levels were also measured using a standard diabetic-management blood-glucose meter. For the 149 T2D subjects, their exhaled breath acetone concentrations ranged from 0.1 to 19.8 ppm; four different ranges of breath acetone concentration, 0.1-19.8, 0.1-7.1, 0.1-6.3, and 0.1-9.5 ppm, were obtained for the subjects under the four different conditions, respectively. For the 42 healthy subjects, their breath acetone concentration ranged from 0.1 to 2.6 ppm; four different ranges of breath acetone concentration, 0.3-2.6, 0.1-2.6, 0.1-1.7, and 0.3-1.6 ppm, were obtained for the four different conditions. The mean breath acetone concentration of the 149 T2D subjects was determined to be 1.5 ± 1.5 ppm, which was 1.5 times that of 1.0 ± 0.6 ppm for the 42 healthy subjects. No correlation was found between the breath acetone concentration and the blood glucose level of the T2D subjects and the healthy volunteers. This study using a relatively large number of

  18. [Breath tests in children with suspected lactose intolerance].

    PubMed

    Parra, P Ángela; Furió, C Simone; Arancibia, A Gabriel

    2015-01-01

    Up to 70% of the world population is lactose intolerance. However, there are no epidemiological studies among Chilean pediatric population affected by this condition. Clinical characterization of a series of children who underwent the lactose intolerance breath test for lactose intolerance study, establishing intolerance and malabsorption frequencies, the most frequent symptoms, and test performance depending on the origin. Patients under 18 years old who took the lactose intolerance breath test in the Gastroenterology Laboratory of the Catholic University of Chile, and who were admitted due to clinically suspected lactose intolerance. Malabsorption was considered when there was as an increase of ≥20ppm above the baseline (H2) or ≥34ppm of H2 and methane (CH4) combined. Intolerance was considered when the above was associated with a symptom intensity score ≥7 during registration. The analysis included194 patients aged 1 to17 years of age. Of these, 102 (53%) presented with malabsorption, and 53 (27%) were intolerant. The frequency of lactose intolerance varied from 7.1 to 45.4%, and it occurred more frequently at older ages. The most common reported symptoms were abdominal pain, bloating and rumbling. Lactose malabsorption and intolerance can be investigated from the first years of life using the lactose breath test plus a symptom questionnaire. An increase in the frequency of intolerance with age, and a greater number of positive tests, if they were requested by a gastroenterologist, were observed. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Optoacoustic 13C-breath test analyzer

    NASA Astrophysics Data System (ADS)

    Harde, Hermann; Helmrich, Günther; Wolff, Marcus

    2010-02-01

    The composition and concentration of exhaled volatile gases reflects the physical ability of a patient. Therefore, a breath analysis allows to recognize an infectious disease in an organ or even to identify a tumor. One of the most prominent breath tests is the 13C-urea-breath test, applied to ascertain the presence of the bacterium helicobacter pylori in the stomach wall as an indication of a gastric ulcer. In this contribution we present a new optical analyzer that employs a compact and simple set-up based on photoacoustic spectroscopy. It consists of two identical photoacoustic cells containing two breath samples, one taken before and one after capturing an isotope-marked substrate, where the most common isotope 12C is replaced to a large extent by 13C. The analyzer measures simultaneously the relative CO2 isotopologue concentrations in both samples by exciting the molecules on specially selected absorption lines with a semiconductor laser operating at a wavelength of 2.744 μm. For a reliable diagnosis changes of the 13CO2 concentration of 1% in the exhaled breath have to be detected at a concentration level of this isotope in the breath of about 500 ppm.

  20. 13C-methacetin and 13C-galactose breath tests can assess restricted liver function even in early stages of primary biliary cirrhosis.

    PubMed

    Holtmeier, Julia; Leuschner, Maria; Schneider, Arne; Leuschner, Ulrich; Caspary, Wolfgang F; Braden, Barbara

    2006-11-01

    The 13C-methacetin breath test quantitatively evaluates cytochrome P450-dependent liver function. The 13C-galactose breath test non-invasively measures the galactose oxidation capacity of the liver. The aim of this study was to find out whether these breath tests are sensitive parameters also in non-cirrhotic patients with primary biliary cirrhosis. Nineteen patients with early-stage primary biliary cirrhosis (no cirrhotic alterations in the liver biopsy, Ludwig stage I-III) and 20 healthy controls underwent the 13C-methacetin and 13C-galactose breath tests. Patients with primary biliary cirrhosis metabolized less 13C-methacetin than controls (cumulative recovery within 30 min 7.5+/-2.4% versus 14.0+/-2.6%; p < 0.001). When a cut-off > 9.8% was used for the cumulative recovery after 30 min, the methacetin breath test reached 84.2% sensitivity and 95.0 specificity. In the 13C-galactose breath test, the percentage recovery at 60 min in patients was 3.1+/-1.3%/h, and 6.3+/-1.1%/h in controls (p < 0.001). Using a cut-off > 4.7%/h, the galactose breath test reached 89.5% sensitivity and 95.0 specificity. In non-cirrhotic, early-stage, primary biliary cirrhosis the 13C-methacetin breath test and the 13C-galactose breath test reliably indicate decreased liver function. The 13C-galactose breath test can also predict the histological score.

  1. Neural control of breathing and CO2 homeostasis

    PubMed Central

    Guyenet, P.G.; Bayliss, D.A

    2015-01-01

    Summary Recent advances have clarified how the brain detects CO2 to regulate breathing (central respiratory chemoreception). These mechanisms are reviewed and their significance is presented in the general context of CO2/pH homeostasis through breathing. At rest, respiratory chemoreflexes initiated at peripheral and central sites mediate rapid stabilization of arterial PCO2 and pH. Specific brainstem neurons (e.g., retrotrapezoid nucleus, RTN; serotonergic) are activated by PCO2 and stimulate breathing. RTN neurons detect CO2 via intrinsic proton receptors (TASK-2, GPR4), synaptic input from peripheral chemoreceptors and signals from astrocytes. Respiratory chemoreflexes are arousal state-dependent whereas chemoreceptor stimulation produces arousal. When abnormal, these interactions lead to sleep-disordered breathing. During exercise, “central command” and reflexes from exercising muscles produce the breathing stimulation required to maintain arterial PCO2 and pH despite elevated metabolic activity. The neural circuits underlying central command and muscle afferent control of breathing remain elusive and represent a fertile area for future investigation. PMID:26335642

  2. Nondispersive infrared spectrometry for 13CO2/12CO2-measurements: a clinically feasible analyzer for stable isotope breath tests in gastroenterology.

    PubMed

    Braden, B; Caspary, W F; Lembcke, B

    1999-06-01

    13C-urea breath tests have become clinical routine for the diagnosis of Helicobacter pylori infection and other isotope breath tests have been invented e.g. for gastric emptying or quantitative liver function testing. Recently, isotope-selective nondispersive infrared spectrometers (NDIRS) have been developed for the analysis of the 13CO2/12CO2-enrichment in breath. In this study, we prospectively tested the validity of a newly developed NDIRS in comparison to isotope ratio mass spectrometry (IRMS). 142 patients with dyspeptic symptoms were tested for Helicobacter pylori infection using the 13C-urea breath test. The isotope ratio analysis of the breath samples was performed in duplicate both using IRMS and NDIRS. The results of the baseline-corrected 13CO2-exhalation values between IRMS and NDIRS were in excellent agreement. The mean difference between both methods was 0.28 +/- 1.93 delta/1000. Evaluating the qualitative urea breath test results in reference to IRMS as the reference the NDIRS had a sensitivity of 97.8% and a specificity of 98.9%. The isotope-selective nondispersive infrared spectroscopy is going to become a reliable, but low-cost and easy-to-operate alternative to expensive isotope ratio mass spectrometry in the analysis of 13C-breath tests.

  3. Prevalence of abnormal lactose breath hydrogen tests in children with functional abdominal pain.

    PubMed

    Garg, Neha; Basu, Srikanta; Singh, Preeti; Kumar, Ruchika; Sharma, Lokesh; Kumar, Praveen

    2017-05-01

    The study was undertaken to determine the prevalence of abnormal lactose breath hydrogen test in children with non-organic chronic abdominal pain. Children with chronic abdominal pain were examined and investigated for organic causes. All children without a known organic cause underwent lactose and glucose breath hydrogen test. After a standard dose of 2 g/kg of lactose to a maximum of 50 g, hydrogen in breath was measured at 15 min intervals for 3 h. A rise of 20 ppm above baseline was considered suggestive of lactose malabsorption. Of 108 children screened, organic causes were found in 46 children. Sixty-two patients without any organic cause underwent hydrogen breath test. Lactose hydrogen breath test (HBT) was positive in 36 of 62 (58%), while 11 (17%) had positive HBT with glucose suggestive of small intestinal bacterial overgrowth (SIBO). Twenty out of 34 (59%) improved on lactose free diet while 8 out of 11 (72%) children of SIBO improved on antibiotics. Lactose malabsorption was seen in 58% of children with non-organic chronic abdominal pain.

  4. Does low dose (13)C-urea breath test maintain a satisfactory accuracy in diagnosing Helicobacter pylori infection?

    PubMed

    Coelho, Luiz Gonzaga Vaz; Silva, Arilto Eleutério da; Coelho, Maria Clara de Freitas; Penna, Francisco Guilherme Cancela e; Ferreira, Rafael Otto Antunes; Santa-Cecilia, Elisa Viana

    2011-01-01

    The standard doses of (13)C-urea in (13)C-urea breath test is 75 mg. To assess the diagnostic accuracy of (13)C-urea breath test containing 25 mg of (13)C-urea comparing with the standard doses of 75 mg in the diagnosis of Helicobacter pylori infection. Two hundred seventy adult patients (96 males, 174 females, median age 41 years) performed the standard (13)C-urea breath test (75 mg (13)C-urea) and repeated the (13)C-urea breath test using only 25 mg of (13)C-urea within a 2 week interval. The test was performed using an infrared isotope analyzer. Patients were considered positive if delta over baseline was >4.0‰ at the gold standard test. One hundred sixty-one (59.6%) patients were H. pylori negative and 109 (40.4%) were positive by the gold standard test. Using receiver operating characteristic analysis we established a cut-off value of 3.4% as the best value of 25 mg (13)C-urea breath test to discriminate positive and negative patients, considering the H. pylori prevalence (95% CI: 23.9-37.3) at our setting. Therefore, we obtained to 25 mg (13)C-urea breath test a diagnostic accuracy of 92.9% (95% CI: 88.1-97.9), sensitivity 83.5% (95% CI: 75.4-89.3), specificity 99.4% (95% CI: 96.6-99.9), positive predictive value 98.3% (95% CI: 92.4-99.4), and negative predictive value 93.0% (95% CI: 88.6-96.1). Low-dose (13)C-urea breath test (25 mg (13)C-urea) does not reach accuracy sufficient to be recommended in clinical setting where a 30% prevalence of H. pylori infection is observed. Further studies should be done to determine the diagnostic accuracy of low doses of (13)C-urea in the urea breath test.

  5. A novel 13C-urea breath test device for the diagnosis of Helicobacter pylori infection: continuous online measurements allow for faster test results with high accuracy.

    PubMed

    Israeli, Eran; Ilan, Yaron; Meir, Shimon Bar; Buenavida, Claudia; Goldin, Eran

    2003-08-01

    The aim of this study is to determine the accuracy of a novel laptop sized 13C-Urea breath test analyzer that continuously measures expired breath and to use its advantages to decrease testing time. One hundred and eighty-six subjects (mean age of 47.8 years) were tested simultaneously by the BreathID system (Oridion, Israel), and by the traditional IRMS. BreathID continuously measured the expired breath for a ratio of 13CO(2):12CO(2.) This value was expressed as delta over baseline (DOB) and displayed graphically on a screen in real time. One hundred and one subjects were positive and 85 were negative for H. pylori by isotope ratio mass spectrometry (IRMS). The correlation for the BreathID system at 30 minutes was 100% for positive cases and 98% for negative cases. Analysis of the continuous curves generated by the BreathID for all patients permitted definition of different DOB thresholds for a positive or negative result at shorter time intervals. Thus, after 6 minutes a conclusive test result could be obtained for 64% of subjects, and after 10 minutes for 92% of subjects. The 13C-Urea breath test utilizing the technology of molecular correlation spectrometry is an accurate method for determining infection by H. pylori. The advantage of continuous measurements can shorten testing time without compromising accuracy.

  6. Direct Detection of C_2H_2 in Air and Human Breath by Cw-Crds

    NASA Astrophysics Data System (ADS)

    Schmidt, Florian M.; Vaittinen, Olavi; Metsälä, Markus; Halonen, Lauri

    2010-06-01

    Continuous wave cavity ring-down spectroscopy (cw-CRDS) is an established cavity-enhanced absorption technique that can provide the necessary sensitivity, selectivity and fast acquisition time for many applications involving the detection of trace species. We present a simple but highly sensitive cw-CRDS spectrometer based on an external cavity diode laser operating in the near-infrared region. This instrument allows us to directly detect acetylene (C_2H_2) mixing ratios in air with a detection limit of 120 parts per trillion by volume (pptv) measuring on a C_2H_2 absorption line at 6565.620 cm-1. Acetylene is a combustion product that is routinely used in environmental monitoring as a marker for anthropogenic emissions. In a recent work, the spectrometer was employed to measure the level of acetylene in indoor and outdoor air in Helsinki. Continuous flow measurements with high time resolution (one minute) revealed strong fluctuations in the acetylene mixing ratio in outdoor air during daytime. Due to its non-invasive nature and fast response time, the analysis of exhaled breath for medical diagnostics is an excellent and straightforward alternative to methods using urine or blood samples. In an ongoing study, the cw-CRDS instrument is used to establish the baseline level of acetylene in the breath of the healthy population. An elevated amount of acetylene in breath could indicate exposure to combustion exhausts or other volatile organic compound (VOC) rich sources. The latest results of this investigation will be presented. F. M. Schmidt, O. Vaittinen, M. Metsälä, P. Kraus and L. Halonen, submitted for publication in Appl. Phys. B.

  7. Establishment of a Quick and Highly Accurate Breath Test for ALDH2 Genotyping

    PubMed Central

    Aoyama, Ikuo; Ohashi, Shinya; Amanuma, Yusuke; Hirohashi, Kenshiro; Mizumoto, Ayaka; Funakoshi, Makiko; Tsurumaki, Mihoko; Nakai, Yukie; Tanaka, Katsuyuki; Hanada, Mariko; Uesaka, Aki; Chiba, Tsutomu; Muto, Manabu

    2017-01-01

    Objectives: Acetaldehyde, the first metabolite of ethanol, is a definite carcinogen for the esophagus, head, and neck; and aldehyde dehydrogenase 2 (ALDH2) is a mitochondrial enzyme that catalyzes the metabolism of acetaldehyde. The ALDH2 genotype exists as ALDH2*1/*1 (active ALDH2), ALDH2*1/*2 (heterozygous inactive ALDH2), and ALDH2*2/*2 (homozygous inactive ALDH2). Many epidemiological studies have reported that ALDH2*2 carriers are at high risk for esophageal or head and neck squamous cell carcinomas by habitual drinking. Therefore, identification of ALDH2*2 carriers would be helpful for the prevention of those cancers, but there have been no methods suitable for mass screening to identify these individuals. Methods: One hundred and eleven healthy volunteers (ALDH2*1/*1 carriers: 53; ALDH2*1/*2 carriers: 48; and ALDH2*2/*2 carriers: 10) were recruited. Breath samples were collected after drinking 100 ml of 0.5% ethanol using specially designed gas bags, and breath ethanol and acetaldehyde levels were measured by semiconductor gas chromatography. Results: The median (range) breath acetaldehyde levels at 1 min after alcohol ingestion were 96.1 (18.1–399.0) parts per billion (p.p.b.) for the ALDH2*1/*1 genotype, 333.5 (78.4–1218.4) p.p.b. for the ALDH2*1/*2 genotype, and 537.1 (213.2–1353.8) p.p.b. for the ALDH2*2/*2 genotype. The breath acetaldehyde levels in ALDH2*2 carriers were significantly higher than for the ALDH2*1/*1 genotype. Notably, the ratio of breath acetaldehyde level-to-breath ethanol level could identify carriers of the ALDH2*2 allele very accurately (whole accuracy; 96.4%). Conclusions: Our novel breath test is a useful tool for identifying ALDH2*2 carriers, who are at high risk for esophageal and head and neck cancers. PMID:28594397

  8. The effect of breath freshener strips on two types of breath alcohol testing instruments.

    PubMed

    Moore, Ronald L; Guillen, Jennifer

    2004-07-01

    The potential for breath freshener strips to interfere with the accuracy of a breath alcohol test was studied. Twelve varieties of breath freshener strips from five manufacturers were examined. Breath tests were conducted using the infrared based BAC DataMaster or the fuel cell based Alco-Sensor IV-XL, 30 and 150 seconds after placing a breath strip on the tongue. No effect was observed using the Alco-Sensor system. Some of the strips gave a small reading at 30 seconds (less than or equal to 0.010 g/210 L apparent alcohol) using the DataMaster. Readings on the DataMaster returned to zero by the 150 second test. A proper pre-test observation and deprivation period should prevent any interference from breath freshener strips on breath alcohol testing.

  9. Intraoral pH and temperature during sleep with and without mouth breathing.

    PubMed

    Choi, J E; Waddell, J N; Lyons, K M; Kieser, J A

    2016-05-01

    To measure and compare the intraoral pH and temperature of individuals during sleep with and without mouth breathing. Ten healthy participants [mean age = 25·8 (± 4·3)] wore a custom-made appliance fitted with a pH probe and thermocouple for two sets of 48 h. Continuous pH and temperature measurements were taken from the palatal aspect of the upper central incisors. To simulate mouth breathing during sleep, participants wore a nose clip for two nights of the four, with the first group (n = 5) wearing the nose clip during the first night and the rest (n = 5) wearing the nose clip during the second night of sleep to balance any potential bias from the wearing sequence. Both qualitative and quantitative analyses were conducted. The mean intraoral pH during daytime was 7·3 (± 0·4) and during sleep was 7·0 (± 0·5). The mean intraoral pH during sleep with mouth breathing was 6·6 (± 0·5), which was statistically significant compared with the normal sleep condition (P < 0·01). The intraoral pH decreased slowly over the hours of sleep in all participants. When sleeping with forced mouth breathing, intraoral pH showed a greater fall over a longer period of time. The mean intraoral temperature was 33·1 °C (± 5·2) during daytime and 33·3 °C (± 6·1) during sleep, with no statistical significance between sleep with and without mouth breathing (P > 0·05). The results suggest that mouth breathing during sleep is related to a decrease in intraoral pH compared with normal breathing during sleep, and this has been proposed as a causal factor for dental erosion and caries. © 2015 John Wiley & Sons Ltd.

  10. Clinical applications of breath testing

    PubMed Central

    Paschke, Kelly M; Mashir, Alquam

    2010-01-01

    Breath testing has the potential to benefit the medical field as a cost-effective, non-invasive diagnostic tool for diseases of the lung and beyond. With growing evidence of clinical worth, standardization of methods, and new sensor and detection technologies the stage is set for breath testing to gain considerable attention and wider application in upcoming years. PMID:21173863

  11. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Breath-alcohol test system. 862.3050 Section 862....3050 Breath-alcohol test system. (a) Identification. A breath-alcohol test system is a device intened to measure alcohol in the human breath. Measurements obtained by this device are used in the...

  12. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Breath-alcohol test system. 862.3050 Section 862....3050 Breath-alcohol test system. (a) Identification. A breath-alcohol test system is a device intened to measure alcohol in the human breath. Measurements obtained by this device are used in the...

  13. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Apparatus § 84.88 Breathing bag test. (a) Breathing bags will be tested in an air atmosphere saturated with... Institute upon request. (d) The air within the bag(s) shall not contain more than 100 parts per million of... 42 Public Health 1 2014-10-01 2014-10-01 false Breathing bag test. 84.88 Section 84.88 Public...

  14. New optical analyzer for 13C-breath test

    NASA Astrophysics Data System (ADS)

    Harde, Hermann; Dressler, Matthias; Helmrich, Günther; Wolff, Marcus; Groninga, Hinrich

    2008-04-01

    Medical breath tests are well established diagnostic tools, predominantly for gastroenterological inspections, but also for many other examinations. Since the composition and concentration of exhaled volatile gases reflect the physical condition of a patient, a breath analysis allows one to recognize an infectious disease in an organ or even to identify a tumor. One of the most prominent breath tests is the 13C-urea-breath test, applied to ascertain the presence of the bacterium helicobacter pylori in the stomach wall as an indication of a gastric ulcer. In this contribution we present a new optical analyzer that is based on photoacoustic spectroscopy and uses a DFB diode laser at 2.744 μm. The concentration ratio of the CO II isotopologues is determined by measuring the absorption on a 13CO II line in comparison to a 12CO II line. In the specially selected spectral range the lines have similar strengths, although the concentrations differ by a factor of 90. Therefore, the signals are well comparable. Due to an excellent signal-noise-ratio isotope variations of less than 1% can be resolved as required for the breath test.

  15. Laboratory testing of two prototype in-vehicle breath test devices

    DOT National Transportation Integrated Search

    1985-08-01

    This report presents the results of laboratory testing of two recently developed prototype in-vehicle breath test devices. These devices are designed to prevent persons with alcohol on their breath from driving a car. The devices tested were the SOBE...

  16. Variability of exhaled breath condensate pH in lung transplant recipients.

    PubMed

    Czebe, Krisztina; Kullmann, Tamas; Csiszer, Eszter; Barat, Erzsebet; Horvath, Ildiko; Antus, Balazs

    2008-01-01

    Measurement of pH in exhaled breath condensate (EBC) may represent a novel method for investigating airway pathology. The aim of this longitudinal study was to assess the variability of EBC pH in stable lung transplant recipients (LTR). During routine clinical visits 74 EBC pH measurements were performed in 17 LTR. EBC pH was also measured in 19 healthy volunteers on four separate occasions. EBC pH was determined at standard CO2 partial pressure by a blood gas analyzer. Mean EBC pH in clinically stable LTR and in controls was similar (6.38 +/- 0.09 vs. 6.44 +/- 0.16; p = nonsignificant). Coefficient of variation for pH in LTR and controls was 2.1 and 2.3%, respectively. The limits of agreement for between-visit variability determined by the Bland-Altman test in LTR and healthy volunteers were also comparable (-0.29 and 0.46 vs. -0.53 and 0.44). Our data suggest that the variability of EBC pH in stable LTR is relatively small, and it is similar to that in healthy nontransplant subjects.

  17. Monitoring of rapid blood pH variations by CO detection in breath with tunable diode laser

    NASA Astrophysics Data System (ADS)

    Kouznetsov, Andrian I.; Stepanov, Eugene V.; Zyrianov, Pavel V.; Shulagin, Yurii A.; Diachenko, Alexander I.; Gurfinkel, Youri I.

    1997-06-01

    Detection of endogenous carbon monoxide content in breath with tunable diode lasers (TDL) was proposed for noninvasive monitoring of rapid blood pH variation. Applied approach is based on high sensitivity of the haemoglobin and myoglobin affinity for CO to blood pH value and an ability to detect rapidly small variations of CO content in expired air. Breath CO absorption in 4.7 micrometers spectral region was carefully measured using PbSSe tunable diode laser that can provide 1 ppb CO concentration sensitivity and 10 s time constant. Applied TDL gas analyzer was used to monitor expired air of studied persons in physiological tests including hyperventilation and physical load. Simultaneous blood tests were conducted to demonstrate correlation between blood and breath chemical parameters.

  18. A Modified Carbon Monoxide Breath Test for Measuring Erythrocyte Lifespan in Small Animals

    PubMed Central

    Ma, Yong-Jian; Zhang, Hou-De; Ji, Yong-Qiang; Zhu, Guo-Liang; Huang, Jia-Liang; Du, Li-Tao; Cao, Ping; Zang, De-Yue; Du, Ji-Hui; Li, Rong; Wang, Lei

    2016-01-01

    This study was to develop a CO breath test for RBC lifespan estimation of small animals. The ribavirin induced hemolysis rabbit models were placed individually in a closed rebreath cage and air samples were collected for measurement of CO concentration. RBC lifespan was calculated from accumulated CO, blood volume, and hemoglobin concentration data. RBC lifespan was determined in the same animals with the standard biotin-labeling method. RBC lifespan data obtained by the CO breath test method for control (CON, 49.0 ± 5.9 d) rabbits, rabbits given 10 mg/kg·d−1 of ribavirin (RIB10, 31.0 ± 4.0 d), and rabbits given 20 mg/kg·d−1 of ribavirin (RIB20, 25.0 ± 2.9 d) were statistically similar (all p > 0.05) to and linearly correlated (r = 0.96, p < 0.01) with the RBC lifespan data obtained for the same rabbits by the standard biotin-labeling method (CON, 51.0 ± 2.7 d; RIB10, 33.0 ± 1.3 d; and RIB20, 27.0 ± 0.8 d). The CO breath test method takes less than 3 h to complete, whereas the standard method requires at least several weeks. In conclusion, the CO breath test method provides a simple and rapid means of estimating RBC lifespan and is feasible for use with small animal models. PMID:27294128

  19. Simplified 13C-urea breath test with a new infrared spectrometer for diagnosis of Helicobacter pylori infection.

    PubMed

    Chen, Tseng-Shing; Chang, Full-Young; Chen, Pang-Chi; Huang, Thomas W; Ou, Jonathan T; Tsai, Ming-Hung; Wu, Ming-Shiang; Lin, Jaw-Town

    2003-11-01

    Infrared spectrometry has correlated excellently with mass spectrometry in detecting the ratio of 13CO(2) to 12CO(2) in breath samples. The present study aimed to evaluate the accuracy of the 13C-urea breath test (13C-UBT) using a new model of infrared analyzer. A total of 600 patients who were undergoing upper endoscopy without receiving eradication therapy were entered into the study. Culture, histology, and rapid urease test on biopsies from the antrum and corpus of the stomach were used for the determination of Helicobacter pylori infection. Breath samples were collected before and 20 min after drinking 100 mg 13C-urea in 100 mL water. The optimal cutoff value was determined by the receiver operating characteristic curve. Of the 586 patients who were eligible for analysis, 369 were positive for H. pylori infection, 185 were negative for H. pylori infection, and 32 were indeterminate. When the appropriate cutoff value was set at 3.5 per thousand, a sensitivity of 97.8%, a specificity of 96.8% and an accuracy of 97.5% were obtained using the 13C-UBT. The accuracy of the 13C-UBT decreased when CO(2) concentration in the breath sample was <2%, as compared with > or = 2% (93.6%vs 97.7%), mainly because of a decrease in specificity (81.8%vs 97.7%). There were 2.7% of patients with Delta13CO(2) values that fell between 3.0-4.5 per thousand, in whom the risk of error was 47%. The 13C-UBT performed with infrared spectrometry is a highly sensitive, specific, and non-invasive method for the detection of H. pylori infection. The immediate availability of the test result and technical simplicity make it particularly effective in routine clinical practice.

  20. Effects of breathing pattern and inspired air conditions on breath condensate volume, pH, nitrite, and protein concentrations.

    PubMed

    McCafferty, J B; Bradshaw, T A; Tate, S; Greening, A P; Innes, J A

    2004-08-01

    The effects of breathing pattern and inspired air conditions on the volume and content of exhaled breath condensate (EBC) were investigated. Total exhaled water (TEW), EBC volume, pH, nitrite and protein concentrations were measured in three groups of 10 healthy subjects breathing into a condenser at different target minute ventilations (Vm), tidal volumes (Vt), and inspired air conditions. The volumes of both TEW and EBC increased significantly with Vm. For Vm 7.5, 15 and 22.5 l/min, mean (SD) EBC was 627 (258) microl, 1019 (313) microl, and 1358 (364) microl, respectively (p<0.001) and TEW was 1879 (378) microl, 2986 (496) microl, and 4679 (700) microl, respectively (p<0.001). TEW was significantly higher than EBC, reflecting a condenser efficiency of 40% at a target Vm of 7.5 l/min which reduced to 29% at Vm 22.5 l/min. Lower Vt gave less TEW than higher Vt (26.6 v 30.7 microl/l, mean difference 4.1 (95% CI 2.6 to 5.6), p<0.001) and a smaller EBC volume (4.3 v 7.6 microl/l, mean difference 3.4 (95% CI 2.3 to 4.5), p<0.001). Cooler and drier inspired air yielded less water vapour and less breath condensate than standard conditions (p<0.05). Changes in the breathing pattern had no effect on EBC protein and nitrite concentrations and pH. These results show that condensate volume can be increased by using high Vt and increased Vm without compromising the dilution of the sample.

  1. On the importance of developing a new generation of breath tests for Helicobacter pylori detection.

    PubMed

    Kushch, Ievgeniia; Korenev, Nikolai; Kamarchuk, Lyudmila; Pospelov, Alexander; Kravchenko, Andrey; Bajenov, Leonid; Kabulov, Mels; Amann, Anton; Kamarchuk, Gennadii

    2015-12-15

    State-of-the-art methods for non-invasive detection of the Helicobacter pylori (H. pylori) infection have been considered. A reported global tendency towards a non-decreasing prevalence of H. pylori worldwide could be co-influenced by the functional limitations of urea breath tests (UBTs), currently preferred for the non-invasive recognition of H. pylori in a clinical setting. Namely, the UBTs can demonstrate false-positive or false-negative results. Within this context, limitations of conventional clinically exploited H. pylori tests have been discussed to justify the existing need for the development of a new generation of breath tests for the detection of H. pylori and the differentiation of pathogenic and non-pathogenic strains of the bacterium. This paper presents the results of a pilot clinical study aimed at evaluating the development and diagnostic potential of a new method based on the detection of the non-urease products of H. pylori vital activity in exhaled gas. The characteristics of breath of adolescents with H. pylori-positive and H. pylori-negative functional dyspepsia, together with a consideration of the cytotoxin-associated gene A (CagA) status of H. pylori-positive subjects, have been determined for the first time using innovative point-contact nanosensor devices based on salts of the organic conductor tetracyanoquinodimethane (TCNQ). The clinical and diagnostic relevance of the response curves of the point-contact sensors was assessed. It was found that the recovery time of the point-contact sensors has a diagnostic value for differentiation of the H. pylori-associated peptic ulcer disease. The diagnostically significant elongation of the recovery time was even more pronounced in patients infected with CagA-positive H. pylori strains compared to the CagA-negative patients. Taking into account the operation of the point-contact sensors in the real-time mode, the obtained results are essential prerequisites for the development of a fast and

  2. 46 CFR 197.450 - Breathing gas tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Breathing gas tests. 197.450 Section 197.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE OCCUPATIONAL SAFETY AND HEALTH STANDARDS GENERAL PROVISIONS Commercial Diving Operations Periodic Tests and Inspections of Diving Equipment § 197.450 Breathing gas tests. The diving...

  3. Clinical significance of the glucose breath test in patients with inflammatory bowel disease.

    PubMed

    Lee, Ji Min; Lee, Kang-Moon; Chung, Yoon Yung; Lee, Yang Woon; Kim, Dae Bum; Sung, Hea Jung; Chung, Woo Chul; Paik, Chang-Nyol

    2015-06-01

    Small intestinal bacterial overgrowth which has recently been diagnosed with the glucose breath test is characterized by excessive colonic bacteria in the small bowel, and results in gastrointestinal symptoms that mimic symptoms of inflammatory bowel disease. This study aimed to estimate the positivity of the glucose breath test and investigate its clinical role in inflammatory bowel disease. Patients aged > 18 years with inflammatory bowel disease were enrolled. All patients completed symptom questionnaires. Fecal calprotectin level was measured to evaluate the disease activity. Thirty historical healthy controls were used to determine normal glucose breath test values. A total of 107 patients, 64 with ulcerative colitis and 43 with Crohn's disease, were included. Twenty-two patients (20.6%) were positive for the glucose breath test (30.2%, Crohn's disease; 14.1%, ulcerative colitis). Positive rate of the glucose breath test was significantly higher in patients with Crohn's disease than in healthy controls (30.2% vs 6.7%, P=0.014). Bloating, flatus, and satiety were higher in glucose breath test-positive patients than glucose breath test-negative patients (P=0.021, 0.014, and 0.049, respectively). The positivity was not correlated with the fecal calprotectin level. The positive rate of the glucose breath test was higher in patients with inflammatory bowel disease, especially Crohn's disease than in healthy controls; gastrointestinal symptoms of patients with inflammatory bowel disease were correlated with this positivity. Glucose breath test can be used to manage intestinal symptoms of patients with inflammatory bowel disease. © 2015 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  4. In vivo assessment of the mitochondrial response to caloric restriction in obese women by the 2-keto[1-C]isocaproate breath test.

    PubMed

    Parra, Dolores; González, Alvaro; Martínez, J Alfredo; Labayen, Idoia; Díez, Nieves

    2003-04-01

    The 2-keto[1-(13)C]isocaproate breath test has been proposed as a tool to detect mitochondrial dysfunction in alcoholic liver disease. The aim of this study was to evaluate if the 2-keto[1-(13)C]isocaproate breath test could detect in vivo dynamic changes on mitochondrial activity due to caloric restriction in obese women. Fifteen obese women (body mass index [BMI] > 30 kg/m(2)) participated in the study at baseline. Ten of these women agreed to participate on a diet program to induce body weight loss. Fifteen lean women (BMI < 25 kg/m(2)) were included as a control group. The breath test was performed by the oral administration of the tracer measuring (13)CO(2) enrichment in breath before and after ingestion using isotope ratio mass spectrometry. Body composition, resting energy expenditure, and plasma levels of insulin and leptin were measured. There were no relationships observed between the 2-keto[1-(13)C]isocaproate breath test and the plasma insulin (before diet: P =.863; after diet: P =.879), or leptin (before diet: P =.500; after diet: P =.637). In obese women before treatment, kilograms of fat free mass (P =.108), resting energy expenditure adjusted for body composition (P =.312), and the 2-keto[1-(13)C]isocaproate breath test (P =.205) were similar in comparison to lean women. However, 2-keto[1-(13)C]isocaproate oxidation tended to increase after dieting and was significantly higher than in controls (P =.015). These data suggest that the 2-keto[1-(13)C]isocaproate breath test reflected the adaptive modifications in mitochondrial oxidation in response to caloric restriction in obese women. Copyright 2003 Elsevier, Inc. All rights reserved.

  5. Effects of breathing pattern and inspired air conditions on breath condensate volume, pH, nitrite, and protein concentrations

    PubMed Central

    McCafferty, J; Bradshaw, T; Tate, S; Greening, A; Innes, J

    2004-01-01

    Background: The effects of breathing pattern and inspired air conditions on the volume and content of exhaled breath condensate (EBC) were investigated. Methods: Total exhaled water (TEW), EBC volume, pH, nitrite and protein concentrations were measured in three groups of 10 healthy subjects breathing into a condenser at different target minute ventilations (Vm), tidal volumes (Vt), and inspired air conditions. Results: The volumes of both TEW and EBC increased significantly with Vm. For Vm 7.5, 15 and 22.5 l/min, mean (SD) EBC was 627 (258) µl, 1019 (313) µl, and 1358 (364) µl, respectively (p<0.001) and TEW was 1879 (378) µl, 2986 (496) µl, and 4679 (700) µl, respectively (p<0.001). TEW was significantly higher than EBC, reflecting a condenser efficiency of 40% at a target Vm of 7.5 l/min which reduced to 29% at Vm 22.5 l/min. Lower Vt gave less TEW than higher Vt (26.6 v 30.7 µl/l, mean difference 4.1 (95% CI 2.6 to 5.6), p<0.001) and a smaller EBC volume (4.3 v 7.6 µl/l, mean difference 3.4 (95% CI 2.3 to 4.5), p<0.001). Cooler and drier inspired air yielded less water vapour and less breath condensate than standard conditions (p<0.05). Changes in the breathing pattern had no effect on EBC protein and nitrite concentrations and pH. Conclusion: These results show that condensate volume can be increased by using high Vt and increased Vm without compromising the dilution of the sample. PMID:15282391

  6. Effect of a single brushing with two Zn-containing toothpastes on VSC in morning breath: a 12 h, randomized, double-blind, cross-over clinical study.

    PubMed

    Young, A; Jonski, G

    2011-12-01

    This randomized, double-blind, 12 h clinical study tested the effect of a single brushing with two Zn-containing toothpastes on volatile sulfur compound (VSC) levels in morning breath. The following toothpastes were each tested by all 28 participants: A-Zn toothpaste, B--experimental toothpaste (Zn citrate + PVM/MA copolymer) and C--control toothpaste without Zn. The evening prior to test days participants brushed their teeth for 2 min with 1 g toothpaste. 12 h later and prior to eating or performing oral hygiene, morning breath levels of VSC (H(2)S, CH(3)SH) were analysed by gas chromatography. Subjects then rinsed for 30 s with 5 ml cysteine and breath samples were analysed for H(2)S (H(2)S(cys)). Median VSC (area under the curve) values were compared for A, B and C and the effects of A and B on VSC were compared with C. Toothpaste B was more effective than both toothpastes A and C in reducing H(2)S, CH(3)SH and H(2)S(cys) (p < 0.05). Compared with toothpaste C, toothpastes A and B reduced H(2)S by 35% and 68%, respectively (p = 0.003), and CH(3)SH by 12% and 47%, respectively (p = 0.002). Toothpaste B reduced H(2)S(cys) by 48% compared with toothpaste C (p = 0.001). It is suggested that the superior effect of the experimental toothpaste was most likely due to a higher Zn concentration combined with longer retention of Zn due to the PVM/MA copolymer.

  7. Normalizing CO2 in chronic hyperventilation by means of a novel breathing mask: a pilot study.

    PubMed

    Johansen, Troels; Jack, Sandy; Dahl, Ronald

    2013-10-01

    Chronic idiopathic hyperventilation (CIH) is a form of dysfunctional breathing that has proven hard to treat effectively. To perform a preliminary test of the hypothesis that by periodically inducing normocapnia over several weeks, it would be possible to raise the normal resting level of CO2 and achieve a reduction of symptoms. Six CIH patients were treated 2 h a day for 4 weeks with a novel breathing mask. The mask was used to induce normocapnia in these chronically hypocapnic patients. Capillary blood gases and acid/base parameters [capillary CO2 tension (PcapCO2 ), pH, and standard base excess (SBE)] were measured at baseline and once each week at least 3 h after mask use, as well as spirometric values, breath-holding tolerance and hyperventilation symptoms as per the Nijmegen Questionnaire (NQ). The mask treatment resulted in a significant increase of resting PcapCO2 (+0.45 kPa, P = 0.028), a moderate increase in SBE (+1.4 mEq/L, P = 0.035) and a small reduction in daily symptoms (-3.8 NQ units, P = 0.046). The effect was most pronounced in the first 2 weeks of treatment. By inducing normocapnia with the breathing mask 2 h a day for 4 weeks, the normal resting CO2 and acid/base levels in chronically hyperventilating patients were partially corrected, and symptoms were reduced. © 2013 John Wiley & Sons Ltd.

  8. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  9. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  10. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  11. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  12. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  13. Photoacoustic sensor for VOCs: first step towards a lung cancer breath test

    NASA Astrophysics Data System (ADS)

    Wolff, Marcus; Groninga, Hinrich G.; Dressler, Matthias; Harde, Hermann

    2005-08-01

    Development of new optical sensor technologies has a major impact on the progression of diagnostic methods. Specifically, the optical analysis of breath is an extraordinarily promising technique. Spectroscopic sensors for the non-invasive 13C-breath tests (the Urea Breath Test for detection of Helicobacter pylori is most prominent) are meanwhile well established. However, recent research and development go beyond gastroenterological applications. Sensitive and selective detection of certain volatile organic compounds (VOCs) in a patient's breath, could enable the diagnosis of diseases that are very difficult to diagnose with contemporary techniques. For instance, an appropriate VOC biomarker for early-stage bronchial carcinoma (lung cancer) is n-butane (C4H10). We present a new optical detection scheme for VOCs that employs an especially compact and simple set-up based on photoacoustic spectroscopy (PAS). This method makes use of the transformation of absorbed modulated radiation into a sound wave. Employing a wavelength-modulated distributed feedback (DFB) diode laser and taking advantage of acoustical resonances of the sample cell, we performed very sensitive and selective measurements on butane. A detection limit for butane in air in the ppb range was achieved. In subsequent research the sensitivity will be successively improved to match the requirements of the medical application. Upon optimization, our photoacoustic sensor has the potential to enable future breath tests for early-stage lung cancer diagnostics.

  14. The glucose breath test: a diagnostic test for small bowel stricture(s) in Crohn's disease.

    PubMed

    Mishkin, Daniel; Boston, Francis M; Blank, David; Yalovsky, Morty; Mishkin, Seymour

    2002-03-01

    The aim of this study was to determine whether an indirect noninvasive indicator of proximal bacterial overgrowth, the glucose breath test, was of diagnostic value in inflammatory bowel disease. Twenty four of 71 Crohn's disease patients tested had a positive glucose breath test. No statistical conclusions could be drawn between the Crohn's disease activity index and glucose breath test status. Of patients with radiologic evidence of small bowel stricture(s), 96.0% had a positive glucose breath test, while only one of 46 negative glucose breath test patients had a stricture. The positive and negative predictive values for a positive glucose breath test as an indicator of stricture formation were 96.0% and 97.8%, respectively. This correlation was not altered in Crohn's disease patients with fistulae or status postresection of the terminal ileum. The data in ulcerative colitis were nondiagnostic. In conclusion, the glucose breath test appears to be an accurate noninvasive inexpensive diagnostic test for small bowel stricture(s) and secondary bacterial overgrowth in Crohn's disease.

  15. A metabolic simulator for unmanned testing of breathing apparatuses in hyperbaric conditions.

    PubMed

    Frånberg, Oskar; Loncar, Mario; Larsson, Åke; Ornhagen, Hans; Gennser, Mikael

    2014-11-01

    A major part of testing of rebreather apparatuses for underwater diving focuses on the oxygen dosage system. A metabolic simulator for testing breathing apparatuses was built and evaluated. Oxygen consumption was achieved through catalytic combustion of propene. With an admixture of carbon dioxide in the propene fuel, the system allowed the respiratory exchange ratio to be set freely within human variability and also made it possible to increase test pressures above the condensation pressure of propene. The system was tested by breathing ambient air in a pressure chamber with oxygen uptake (Vo₂) ranging from 1-4 L · min(-1), tidal volume (VT) from 1-3 L, breathing frequency (f) of 20 and 25 breaths/min, and chamber pressures from 100 to 670 kPa. The measured end-tidal oxygen concentration (Fo₂) was compared to calculated end-tidal Fo₂. The largest average difference in end-tidal Fo₂during atmospheric pressure conditions was 0.63%-points with a 0.28%-point average difference during the whole test. During hyperbaric conditions with pressures ranging from 100 to 670 kPa, the largest average difference in Fo₂was 1.68%-points seen during compression from 100 kPa to 400 kPa and the average difference in Fo₂during the whole test was 0.29%-points. In combination with a breathing simulator simulating tidal breathing, the system can be used for dynamic continuous testing of breathing equipment with changes in VT, f, Vo2, and pressure.

  16. Are Nocturnal Breathing, Sleep, and Cognitive Performance Impaired at Moderate Altitude (1,630-2,590 m)?

    PubMed Central

    Latshang, Tsogyal D.; Lo Cascio, Christian M.; Stöwhas, Anne-Christin; Grimm, Mirjam; Stadelmann, Katrin; Tesler, Noemi; Achermann, Peter; Huber, Reto; Kohler, Malcolm; Bloch, Konrad E.

    2013-01-01

    Study Objectives: Newcomers at high altitude (> 3,000 m) experience periodic breathing, sleep disturbances, and impaired cognitive performance. Whether similar adverse effects occur at lower elevations is uncertain, although numerous lowlanders travel to moderate altitude for professional or recreational activities. We evaluated the hypothesis that nocturnal breathing, sleep, and cognitive performance of lowlanders are impaired at moderate altitude. Design: Randomized crossover trial. Setting: University hospital at 490 m, Swiss mountain villages at 1,630 m and 2,590 m. Participants: Fifty-one healthy men, median (quartiles) age 24 y (20-28 y), living below 800 m. Interventions: Studies at Zurich (490 m) and during 4 consecutive days at 1,630 m and 2,590 m, respectively, 2 days each. The order of altitude exposure was randomized. Polysomnography, psychomotor vigilance tests (PVT), the number back test, several other tests of cognitive performance, and questionnaires were evaluated. Measurements and Results: The median (quartiles) apnea-hypopnea index at 490 m was 4.6/h (2.3; 7.9), values at 1,630 and 2,590 m, day 1 and 2, respectively, were 7.0/h (4.1; 12.6), 5.4/h (3.5; 10.5), 13.1/h (6.7; 32.1), and 8.0/h (4.4; 23.1); corresponding values of mean nocturnal oxygen saturation were 96% (95; 96), 94% (93; 95), 94% (93; 95), 90% (89; 91), 91% (90; 92), P < 0.05 versus 490 m, all instances. Slow wave sleep on the first night at 2,590 m was 21% (18; 25) versus 24% (20; 27) at 490 m (P < 0.05). Psychomotor vigilance and various other measures of cognitive performance did not change significantly. Conclusions: Healthy men acutely exposed during 4 days to hypoxemia at 1,630 m and 2,590 m reveal a considerable amount of periodic breathing and sleep disturbances. However, no significant effects on psychomotor reaction speed or cognitive performance were observed. Clinical Trials Registration: Clinicaltrials.gov: NCT01130948. Citation: Latshang TD; Lo Cascio CM; Stöwhas AC

  17. Outcome of breath tests in adult patients with suspected small intestinal bacterial overgrowth

    PubMed Central

    Mattsson, Johanna; Minaya, Maria Teresa; Monegro, Milka; Lebwohl, Benjamin; Lewis, Suzanne K.; Green, Peter HR; Stenberg, Reidun

    2017-01-01

    Aim: The aim was to investigate breath test outcomes in patients with suspected SIBO and indicative symptoms of SIBO, diagnosed by breath testing. Background: Breath testing is used to detect small intestinal bacterial overgrowth (SIBO) by measuring hydrogen and methane produced by intestinal bacteria. Methods: This retrospective cross sectional study included 311 patients with gastrointestinal symptoms who underwent the breath test for evaluation of SIBO at Celiac Disease Center at Columbia University, New York, in 2014-2015. The patients were divided into two groups based on the physician’s choice: lactulose breath test group (72%) and glucose breath test group (28%). Among them, 38% had a history of celiac disease or non-celiac gluten sensitivity. Results: In total, 46% had a positive breath test: 18% were positive for methane, 24 % positive for hydrogen and 4% positive for both gases (p=0.014). Also, 50% had a positive lactulose breath result and 37% had a positive glucose breath result (p=0.036). The most common symptom for performing the breath test was bloating and the only clinical symptom that significantly showed a positive glucose breath test was increased gas (p=0.028). Conclusion: Lactulose breath test was more often positive than glucose breath test. Positivity for hydrogen was more common than methane. Bloating was the most frequently perceived symptom of the patients undergoing the breath test but the only statistically significant clinical symptom for a positive glucose breath test was increased gas. Furthermore, the results showed that there was no significant association between positive breath test result and gender, age, non-celiac gluten sensitivity or celiac disease. PMID:29118931

  18. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  19. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  20. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  1. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  2. An acetone breath analyzer using cavity ringdown spectroscopy: an initial test with human subjects under various situations

    NASA Astrophysics Data System (ADS)

    Wang, Chuji; Surampudi, Anand B.

    2008-10-01

    We have developed a portable breath acetone analyzer using cavity ringdown spectroscopy (CRDS). The instrument was initially tested by measuring the absorbance of breath gases at a single wavelength (266 nm) from 32 human subjects under various conditions. A background subtraction method, implemented to obtain absorbance differences, from which an upper limit of breath acetone concentration was obtained, is described. The upper limits of breath acetone concentration in the four Type 1 diabetes (T1D) subjects, tested after a 14 h overnight fast, range from 0.80 to 3.97 parts per million by volume (ppmv), higher than the mean acetone concentration (0.49 ppmv) in non-diabetic healthy breath reported in the literature. The preliminary results show that the instrument can tell distinctive differences between the breath from individuals who are healthy and those with T1D. On-line monitoring of breath gases in healthy people post-exercise, post-meals and post-alcohol-consumption was also conducted. This exploratory study demonstrates the first CRDS-based acetone breath analyzer and its potential application for point-of-care, non-invasive, diabetic monitoring.

  3. 13CO2 breath test to measure the hydrolysis of various starch formulations in healthy subjects.

    PubMed Central

    Hiele, M; Ghoos, Y; Rutgeerts, P; Vantrappen, G; de Buyser, K

    1990-01-01

    13CO2 starch breath test was used to study the effect of physicochemical characteristics of starch digestion. As starch is hydrolysed to glucose, which is subsequently oxidised to CO2, differences in 13CO2 excretion after ingestion of different starch products must be caused by differences in hydrolysis rate. To study the effect of the degree of chain branching, waxy starch, containing 98% amylopectin, was compared with high amylose starch, containing 30% amylopectin, and normal crystalline starch, containing 74% amylopectin. The effect of the extent of gelatinisation was studied by comparing extruded starch and crystalline starch. Finally, the possible inhibitory effect of adding wheat fibre to extruded starch on the hydrolysis rate was studied. The 13CO2 excretion from two to four hours after intake of crystalline starch was significantly lower than that of extruded starch. Waxy starch was hydrolysed much faster than high amylose starch, but there was no significant difference between waxy starch and normal crystalline starch. Addition of wheat fibre did not influence the hydrolysis rate. The 13CO2 starch breath test is an attractive test for the study of factors affecting carbohydrate assimilation. PMID:2107133

  4. Breath tests sustainability in hospital settings: cost analysis and reimbursement in the Italian National Health System.

    PubMed

    Volpe, M; Scaldaferri, F; Ojetti, V; Poscia, A

    2013-01-01

    The high demand of Breath Tests (BT) in many gastroenterological conditions in time of limited resources for health care systems, generates increased interest in cost analysis from the point of view of the delivery of services to better understand how use the money to generate value. This study aims to measure the cost of C13 Urea and other most utilized breath tests in order to describe key aspects of costs and reimbursements looking at the economic sustainability for the hospital. A hospital based cost-analysis of the main breath tests commonly delivery in an ambulatory setting is performed. Mean salary for professional nurses and gastroenterologists, drugs/preparation used and disposable materials, purchase and depreciation of the instrument and the testing time was used to estimate the cost, while reimbursements are based on the 2013 Italian National Health System ambulatory pricelist. Variables that could influence the model are considered in the sensitivity analyses. The mean cost for C13--Urea, Lactulose and Lactose BT are, respectively, Euros 30,59; 45,20 and 30,29. National reimbursement often doesn't cover the cost of the analysis, especially considering the scenario with lower number of exam. On the contrary, in high performance scenario all the reimbursement could cover the cost, except for the C13 Urea BT that is high influenced by the drugs cost. However, consideration about the difference between Italian Regional Health System ambulatory pricelist are done. Our analysis shows that while national reimbursement rates cover the costs of H2 breath testing, they do not cover sufficiently C13 BT, particularly urea breath test. The real economic strength of these non invasive tests should be considered in the overall organization of inpatient and outpatient clinic, accounting for complete diagnostic pathway for each gastrointestinal disease.

  5. Breathing simulator of workers for respirator performance test

    PubMed Central

    YUASA, Hisashi; KUMITA, Mikio; HONDA, Takeshi; KIMURA, Kazushi; NOZAKI, Kosuke; EMI, Hitoshi; OTANI, Yoshio

    2014-01-01

    Breathing machines are widely used to evaluate respirator performance but they are capable of generating only limited air flow patterns, such as, sine, triangular and square waves. In order to evaluate the respirator performance in practical use, it is desirable to test the respirator using the actual breathing patterns of wearers. However, it has been a difficult task for a breathing machine to generate such complicated flow patterns, since the human respiratory volume changes depending on the human activities and workload. In this study, we have developed an electromechanical breathing simulator and a respiration sampling device to record and reproduce worker’s respiration. It is capable of generating various flow patterns by inputting breathing pattern signals recorded by a computer, as well as the fixed air flow patterns. The device is equipped with a self-control program to compensate the difference in inhalation and exhalation volume and the measurement errors on the breathing flow rate. The system was successfully applied to record the breathing patterns of workers engaging in welding and reproduced the breathing patterns. PMID:25382381

  6. Breathing simulator of workers for respirator performance test.

    PubMed

    Yuasa, Hisashi; Kumita, Mikio; Honda, Takeshi; Kimura, Kazushi; Nozaki, Kosuke; Emi, Hitoshi; Otani, Yoshio

    2015-01-01

    Breathing machines are widely used to evaluate respirator performance but they are capable of generating only limited air flow patterns, such as, sine, triangular and square waves. In order to evaluate the respirator performance in practical use, it is desirable to test the respirator using the actual breathing patterns of wearers. However, it has been a difficult task for a breathing machine to generate such complicated flow patterns, since the human respiratory volume changes depending on the human activities and workload. In this study, we have developed an electromechanical breathing simulator and a respiration sampling device to record and reproduce worker's respiration. It is capable of generating various flow patterns by inputting breathing pattern signals recorded by a computer, as well as the fixed air flow patterns. The device is equipped with a self-control program to compensate the difference in inhalation and exhalation volume and the measurement errors on the breathing flow rate. The system was successfully applied to record the breathing patterns of workers engaging in welding and reproduced the breathing patterns.

  7. Clinical evaluation of a miniaturized desktop breath hydrogen analyzer.

    PubMed

    Duan, L P; Braden, B; Clement, T; Caspary, W F; Lembcke, B

    1994-10-01

    A small desktop electrochemical H2 analyzer (EC-60-Hydrogen monitor) was compared with a stationary electrochemical H2 monitor (GMI-exhaled Hydrogen monitor). The EC-60-H2 monitor shows a high degree of precision for repetitive (n = 10) measurements of standard hydrogen mixtures (CV 1-8%). The response time for completion of measurement is shorter than that of the GMI-exhaled H2 monitor (37 sec. vs 53 sec.; p < 0.0001), while reset times are almost identical (54 sec. vs 51 sec. n.s). In a clinical setting, breath H2-concentrations measured with the EC-60-H2 monitor and the GMI-exhaled H2 monitor were in excellent agreement with a linear correlation (Y = 1.12X + 1.022, r2 = 0.9617, n = 115). With increasing H2-concentrations the EC-60-H2 monitor required larger sample volumes for maintaining sufficient precision, and sample volumes greater than 200 ml were required with H2-concentrations > 30 ppm. For routine gastrointestinal function testing, the EC-60-H2 monitor is an satisfactory and reliable, easy to use and inexpensive desktop breath hydrogen analyzer, whereas in patients with difficulty in cooperating (children, people with severe pulmonary insufficiency), special care has to be applied to obtain sufficiently large breath samples.

  8. Clinical research on liver reserve function by 13C-phenylalanine breath test in aged patients with chronic liver diseases

    PubMed Central

    2010-01-01

    Background The objective of this study was to investigate whether the 13C-phenylalanine breath test could be useful for the evaluation of hepatic function in elderly volunteers and patients with chronic hepatitis B and liver cirrhosis. Methods L-[1-13C] phenylalanine was administered orally at a dose of 100 mg to 55 elderly patients with liver cirrhosis, 30 patients with chronic hepatitis B and 38 elderly healthy subjects. The breath test was performed at 8 different time points (0, 10, 20, 30, 45, 60, 90, 120 min) to obtain the values of Delta over baseline, percentage 13CO2 exhalation rate and cumulative excretion (Cum). The relationships of the cumulative excretion with the 13C-%dose/h and blood biochemical parameters were investigated. Results The 13C-%dose/h at 20 min and 30 min combined with the cumulative excretion at 60 min and 120 min correlated with hepatic function tests, serum albumin, hemoglobin, platelet and Child-Pugh score. Prothrombin time, total and direct bilirubin were significantly increased, while serum albumin, hemoglobin and platelet, the cumulative excretion at 60 min and 120 min values decreased by degrees of intensity of the disease in Child-Pugh A, B, and C patients (P < 0.01). Conclusions The 13C-phenylalanine breath test can be used as a non-invasive assay to evaluate hepatic function in elderly patients with liver cirrhosis. The 13C-%dose/h at 20 min, at 30 min and cumulative excretion at 60 min may be the key value for determination at a single time-point. 13C-phenylalanine breath test is safe and helpful in distinguishing different stages of hepatic dysfunction for elderly cirrhosis patients. PMID:20459849

  9. Carbon-14 urea breath test: does it work in patients with partial gastric resection?

    PubMed

    Dede, Fuat; Civen, Hüseyin; Dane, Faysal; Aliustaoglu, Mehmet; Turhal, Serdar; Turoglu, Halil Turgut; Inanir, Sabahat

    2015-11-01

    The diagnostic value of Carbon-14 urea breath test (C-14 UBT) in the detection of Helicobacter pylori (H. pylori) infection in non-operated patients has been proved. However, the efficacy of C-14 UBT in patients with partial gastric resection (PGR) has not been evaluated yet. Herein, the results of the C-14 UBT and H. pylori stool antigen test (HpSAT) in this patient group were compared with the endoscopic findings. Multi-breath samples C-14 UBT and HpSAT were performed in all patients on the same day. Histology was used as a gold standard for testing C-14 UBT and HpSAT diagnostic efficacies. 30 patients (mean age: 54.6 ± 11 year) with PGR were included. The sensitivity and specificity of standard C-14 UBT were 29 and 100 %, respectively. When breath samples were collected at 20th min, and >35 CPM was selected as radioactivity threshold, the sensitivity raised to 86 % without any loss of specificity. The specificity and sensitivity of the HpSAT were 71 and 96 %, respectively. The sensitivity of the standard C-14 UBT was very poor for patients with PGR, and results of HpSAT were superior in this population. Certain modifications are needed if C-14 UBT is to be used in PGR patients.

  10. Influence of condensing equipment and temperature on exhaled breath condensate pH, total protein and leukotriene concentrations.

    PubMed

    Czebe, Krisztina; Barta, Imre; Antus, Balázs; Valyon, Márta; Horváth, Ildikó; Kullmann, Tamás

    2008-05-01

    Exhaled breath condensate analysis is an attractive but still not fully standardised method for investigating airway pathology. Adherence of biomarkers to various condensing surfaces and changes in condensing temperature has been considered to be responsible for the variability of the results. Our aims were to compare the efficacy of different types of condensers and to test the influence of condensing temperature on condensate composition. Breath condensates from 12 healthy persons were collected in two settings: (1) by using three condensers of different type (EcoScreen, R-Tube, Anacon) and (2) by using R-Tube condenser either cooled to -20 or -70 degrees C. Condensate pH at standardised CO(2) level was determined; protein content was measured by the Bradford method and leukotrienes by EIA. Breath condensates collected using EcoScreen were more alkaline (6.45+/-0.20 vs. 6.19+/-0.23, p<0.05 and 6.10+/-0.26, p<0.001) and contained more protein (3.89+/-2.03 vs. 2.65+/-1.98, n.s. and 1.88+/-1.99 microg/ml, p<0.004) as compared to the other devices. Only parameters obtained with R-Tube and Anacon correlated. Condensing temperature affected condensate pH (5.99+/-0.20 at -20 degrees C and 5.82+/-0.07 at -70 degrees C, p<0.05) but not protein content. Leukotriene B(4) was not found in any sample and cysteinyl-leukotriene was not found in condensates collected with R-Tube or Anacon. Condenser type influences sample pH, total protein content and cysteinyl-leukotriene concentration. Condensing temperature influences condensate pH but not total protein content. These results suggest that adherence of the biomarkers to condenser surface and condensing temperature may play a role but does not fully explain the variability of EBC biomarker levels.

  11. The Wagner-Nelson method can generate an accurate gastric emptying flow curve from CO2 data obtained by a 13C-labeled substrate breath test.

    PubMed

    Sanaka, Masaki; Yamamoto, Takatsugu; Ishii, Tarou; Kuyama, Yasushi

    2004-01-01

    In pharmacokinetics, the Wagner-Nelson (W-N) method can accurately estimate the rate of drug absorption from its urinary elimination rate. A stable isotope (13C) breath test attempts to estimate the rate of absorption of 13C, as an index of gastric emptying rate, from the rate of pulmonary elimination of 13CO2. The time-gastric emptying curve determined by the breath test is quite different from that determined by scintigraphy or ultrasonography. In this report, we have shown that the W-N method can adjust the difference. The W-N equation to estimate gastric emptying from breath data is as follows: the fractional cumulative amount of gastric contents emptied by time t = Abreath (t)/Abreath (infinity) + (1/0.65).d[Abreath (t)/Abreath (infinity) ]/dt, where Abreath (t) = the cumulative recovery of 13CO2 in breath by time t and Abreath ( infinity ) = the ultimate cumulative 13CO2 recovery. The emptying flow curve generated by ultrasonography was compared with that generated by the W-N method-adjusted breath test in 6 volunteers. The emptying curves by the W-N method were almost identical to those by ultrasound. The W-N method can generate an accurate emptying flow curve from 13CO2 data, and it can adjust the difference between ultrasonography and the breath test. Copyright 2004 S. Karger AG, Basel

  12. Effects of exogenous lactase administration on hydrogen breath excretion and intestinal symptoms in patients presenting lactose malabsorption and intolerance.

    PubMed

    Ibba, Ivan; Gilli, Agnese; Boi, Maria Francesca; Usai, Paolo

    2014-01-01

    To establish whether supplementation with a standard oral dose of Beta-Galactosidase affects hydrogen breath excretion in patients presenting with lactose malabsorption. Ninety-six consecutive patients positive to H2 Lactose Breath Test were enrolled. Mean peak H2 levels, the time to reach the peak H2, the time to reach the cut-off value of 20 ppm, the cumulative breath H2 excretion, the areas under the curve, and a Visual Analogical 10-point Scale for symptoms were calculated. Genotyping of the C/T-13910 variant was carried out. Following the oral administration of Beta-Galactosidase, in 21.88% of the cases, H2 Lactose Breath Test became negative (Group A), while mean peak H2 levels (74.95 ppm versus 7.85), P < 0.0000, in 17.71% (Group B) were still positive, with the H2 level 20 ppm above the baseline, but the peak H2 levels were significantly lower than those observed at the baseline test (186.7 ppm versus 66.64), P < 0.0000, while in 60.41% (Group C) they were still positive with the peak H2 levels similar to those observed at the baseline test (94.43 versus 81.60 ppm). All 96 individuals tested presented the C/C-13910 genotype nonpersistence. The response to oral administration of Beta-Galactosidase in patients with symptoms of lactose malabsorption presents a significant variability.

  13. (13)C-Breath testing in animals: theory, applications, and future directions.

    PubMed

    McCue, Marshall D; Welch, Kenneth C

    2016-04-01

    The carbon isotope values in the exhaled breath of an animal mirror the carbon isotope values of the metabolic fuels being oxidized. The measurement of stable carbon isotopes in carbon dioxide is called (13)C-breath testing and offers a minimally invasive method to study substrate oxidation in vivo. (13)C-breath testing has been broadly used to study human exercise, nutrition, and pathologies since the 1970s. Owing to reduced use of radioactive isotopes and the increased convenience and affordability of (13)C-analyzers, the past decade has witnessed a sharp increase in the use of breath testing throughout comparative physiology--especially to answer questions about how and when animals oxidize particular nutrients. Here, we review the practical aspects of (13)C-breath testing and identify the strengths and weaknesses of different methodological approaches including the use of natural abundance versus artificially-enriched (13)C tracers. We critically compare the information that can be obtained using different experimental protocols such as diet-switching versus fuel-switching. We also discuss several factors that should be considered when designing breath testing experiments including extrinsic versus intrinsic (13)C-labelling and different approaches to model nutrient oxidation. We use case studies to highlight the myriad applications of (13)C-breath testing in basic and clinical human studies as well as comparative studies of fuel use, energetics, and carbon turnover in multiple vertebrate and invertebrate groups. Lastly, we call for increased and rigorous use of (13)C-breath testing to explore a variety of new research areas and potentially answer long standing questions related to thermobiology, locomotion, and nutrition.

  14. Can handling E85 motor fuel cause positive breath alcohol test results?

    PubMed

    Ran, Ran; Mullins, Michael E

    2013-09-01

    Hand-held breath alcohol analyzers are widely used by police in traffic stops of drivers suspected of driving while intoxicated (DWI). E85 is a motor fuel consisting of 85% ethanol and 15% gasoline or other hydrocarbons, and is available at nearly 2,600 stations in the USA. We sought to determine whether handling E85 fuel could produce measurable breath alcohol results using a hand-held analyzer and to see if this would be a plausible explanation for a positive breath alcohol test. Five healthy adult subjects dispensed or transferred 8 US gallons of E85 fuel in each of four scenarios. We measured breath alcohol concentration in g/210 L of exhaled breath using the BACTrack S50 at 0, 2, 4, 6, 8, 10, 15 and 20 min after each fuel-handling scenario. Most of the subjects had no detectable breath alcohol after handling E85 motor fuel. Transient elevations (0.02-0.04 g/210 L) in breath alcohol measurement occurred up to 6 min after handling E85 in a minority of subjects. We conclude that it is unlikely that handling E85 motor fuel would result in erroneous prosecution for DWI.

  15. Cost-effectiveness of the Carbon-13 Urea Breath Test for the Detection of Helicobacter Pylori

    PubMed Central

    Masucci, L; Blackhouse, G; Goeree, R

    2013-01-01

    Objectives This analysis aimed to evaluate the cost-effectiveness of various testing strategies for Helicobacter pylori in patients with uninvestigated dyspepsia and to calculate the budgetary impact of these tests for the province of Ontario. Data Sources Data on the sensitivity and specificity were obtained from the clinical evidence-based analysis. Resource items were obtained from expert opinion, and costs were applied on the basis of published sources as well as expert opinion. Review Methods A decision analytic model was constructed to compare the costs and outcomes (false-positive results, false-negative results, and misdiagnoses avoided) of the carbon-13 (13C) urea breath test (UBT), enzyme-linked immunosorbent assay (ELISA) serology test, and a 2-step strategy of an ELISA serology test and a confirmatory 13C UBT based on the sensitivity and specificity of the tests and prevalence estimates. Results The 2-step strategy is more costly and more effective than the ELISA serology test and results in $210 per misdiagnosis case avoided. The 13C UBT is dominated by the 2-step strategy, i.e., it is more costly and less effective. The budget impact analysis indicates that it will cost $7.9 million more to test a volume of 129,307 patients with the 13C UBT than with ELISA serology, and $4.7 million more to test these patients with the 2-step strategy. Limitations The clinical studies that were pooled varied in the technique used to perform the breath test and in reference standards used to make comparisons with the breath test. However, these parameters were varied in a sensitivity analysis. The economic model was designed to consider intermediate outcomes only (i.e., misdiagnosed cases) and was not a complete model with final patient outcomes (e.g., quality-adjusted life years). Conclusions Results indicate that the 2-step strategy could be economically attractive for the testing of H. pylori. However, testing with the 2-step strategy will cost the Ministry of

  16. Stability of (13) C-Urea Breath Test Samples Over Time in the Diagnosis of Helicobacter pylori.

    PubMed

    Perets, Tsachi Tsadok; Shporn, Einav; Boltin, Doron; Dickman, Ram; Niv, Yaron

    2016-05-01

    The accuracy and repeatability of breath test in the diagnosis of Helicobacter pylori infection have not been adequately investigated. Although it has been shown that storage for long periods does not affect the analysis results, no data are available on the effect of repetitive testing. In this study, our aim was to evaluate the repeatability of the analyses of breath samples at room temperature. A total of 202 positive breath samples were collected in duplicates, before and after administration of 75 mg (13) C- urea dissolved in 100 ml of orange juice. Breath test results were expressed as delta (13) CO2 . The cut-off value was 3.5 parts per thousand. Each sample was analyzed in a mass spectrometer 7, 14, 21, and 28 days after collection. The accuracy calculation was based on the comparison of the delta (13) CO2 obtained in the three consecutive weeks following the first test run to the delta (13) CO2 obtained in the first test run. Two hundred (99%), 197 (97.52%), and 196 (97%) of the 202 samples tested positive in the second, third, and fourth test runs, respectively. The accuracy of the delta (13) CO2 was 98.6%, 99.2%, and 96.7% in the three consecutive runs, respectively. Short-term storage of 1 month does not affect sample stability or the results of (13) C-urea breath tests in up to three consecutive repeats. © 2015 Wiley Periodicals, Inc.

  17. [*C]octanoic acid breath test to measure gastric emptying rate of solids.

    PubMed

    Maes, B D; Ghoos, Y F; Rutgeerts, P J; Hiele, M I; Geypens, B; Vantrappen, G

    1994-12-01

    We have developed a breath test to measure solid gastric emptying using a standardized scrambled egg test meal (250 kcal) labeled with [14C]octanoic acid or [13C]octanoic acid. In vitro incubation studies showed that octanoic acid is a reliable marker of the solid phase. The breath test was validated in 36 subjects by simultaneous radioscintigraphic and breath test measurements. Nine healthy volunteers were studied after intravenous administration of 200 mg erythromycin and peroral administration of 30 mg propantheline, respectively. Erythromycin significantly enhanced gastric emptying, while propantheline significantly reduced gastric emptying rates. We conclude that the [*C]octanoic breath test is a promising and reliable test for measuring the gastric emptying rate of solids.

  18. Operation and testing of Mark 10 Mod 3 underwater breathing apparatus

    NASA Technical Reports Server (NTRS)

    Milwee, W. I., Jr.

    1972-01-01

    Performance tests on a closed circuit, mixed gas underwater breathing apparatus are reported. The equipment is designed to provide a minimum diving duration of four hours at 1500 ft below sea surface; it senses oxygen partial pressure in the breathing gas mix and controls oxygen content of the breathing gas within narrow limits about a preset value. The breathing circuit subsystem provides respirable gas to the diver and removes carbon dioxide and moisture from the expired gas. Test results indicate undesirable variations in oxygen partial pressure with oxygen addition and insufficient carbon dioxide absorption.

  19. Effect of a simethicone-containing tablet on colonic gas elimination in breath.

    PubMed

    Lifschitz, C H; Irving, C S; Smith, E O

    1985-05-01

    The effect of a tablet containing the antiflatulent, simethicone, on intestinal hydrogen (H2) elimination in breath was studied. In three trials, normal subjects (age 12-52 years) received, on subsequent days, lactulose or lactulose with two tablets of either simethicone or placebo in randomized order. Breath samples were collected over 210 min and analyzed by gas chromatography for H2. The time course of H2 expiration above baseline levels was calculated and compared for the three tests. No significant differences in transit time were found. Cumulative H2 expiration was significantly lower after simethicone compared to placebo. H2 production from stool incubated with simethicone or placebo indicated that the drug had no effect in reducing the fermentative production of H2 in vitro. Interestingly, the vehicle present in the tablets could be fermented by intestinal bacteria. Simethicone reduced the amount of H2 eliminated in breath, but this effect was offset partially by H2 production from the fermentation of unabsorbable substances used in the formulation of the tablets.

  20. Variability of breath condensate pH may contribute to the better understanding of non-allergic seasonal respiratory diseases

    NASA Astrophysics Data System (ADS)

    Kullmann, Tamás; Szipőcs, Annamária

    2017-09-01

    The seasonal variability of certain non-allergic respiratory diseases is not clearly understood. Analysis of the breath condensate, the liquid that can be collected by breathing into a cold tube, has been proposed to bring closer to the understanding of airway pathologies. It has been assumed, that (1) airway lining fluid was a stable body liquid and (2) the breath condensate samples were representative of the airway lining fluid. Research was focussed on the identification of biomarkers indicative of respiratory pathologies. Despite 30 years of extended investigations breath condensate analysis has not gained any clinical implementation so far. The pH of the condensate is the characteristic that can be determined with the highest reproducibility. The present paper shows, that contrary to the initial assumptions, breath condensate is not a representative of the airway lining fluid, and the airway lining fluid is not a stable body liquid. Condensate pH shows baseline variability and it is influenced by drinking and by the ambient temperature. The changes in condensate pH are linked to changes in airway lining fluid pH. The variability of airway lining fluid pH may explain seasonal incidence of certain non-allergic respiratory diseases such as the catching of a common cold and the increased incidence of COPD exacerbations and exercise-induced bronchoconstriction in cold periods.

  1. Can Handling E85 Motor Fuel Cause Positive Breath Alcohol Test Results?

    PubMed Central

    Ran, Ran; Mullins, Michael E.

    2013-01-01

    Hand-held breath alcohol analyzers are widely used by police in traffic stops of drivers suspected of driving while intoxicated (DWI). E85 is a motor fuel consisting of 85% ethanol and 15% gasoline or other hydrocarbons, and is available at nearly 2,600 stations in the USA. We sought to determine whether handling E85 fuel could produce measurable breath alcohol results using a hand-held analyzer and to see if this would be a plausible explanation for a positive breath alcohol test. Five healthy adult subjects dispensed or transferred 8 US gallons of E85 fuel in each of four scenarios. We measured breath alcohol concentration in g/210 L of exhaled breath using the BACTrack S50 at 0, 2, 4, 6, 8, 10, 15 and 20 min after each fuel-handling scenario. Most of the subjects had no detectable breath alcohol after handling E85 motor fuel. Transient elevations (0.02–0.04 g/210 L) in breath alcohol measurement occurred up to 6 min after handling E85 in a minority of subjects. We conclude that it is unlikely that handling E85 motor fuel would result in erroneous prosecution for DWI. PMID:23843422

  2. Effects of homeopathic mother tinctures on breath alcohol testing.

    PubMed

    Boatto, Gianpiero; Trignano, Claudia; Burrai, Lucia; Spanu, Andrea; Nieddu, Maria

    2015-01-01

    In some countries, it is illegal to drive with any detectable amount of alcohol in blood; in others, the legal limit is 0.5 g/L or lower. Recently, some defendants charged with driving under the influence of alcohol and have claimed that positive breath alcohol test results were due to the ingestion of homeopathic mother tinctures. These preparations are obtained by maceration, digestion, infusion, or decoction of herbal material in hydroalcoholic solvent. A series of tests were conducted to evaluate the alcoholic content of three homeopathic mother tinctures and their ability to produce inaccurate breath alcohol results. Nine of 30 subjects gave positive results (0.11-0.82 g/L) when tests were taken within 1 min after drinking mother tincture. All tests taken at least 15 min after the mother tincture consumption and resulted in alcohol-free readings. An observation period of 15-20 min prior to breath alcohol testing eliminates the possibility of false-positive results. © 2014 American Academy of Forensic Sciences.

  3. Influence of different proton pump inhibitors on activity of cytochrome P450 assessed by [(13)C]-aminopyrine breath test.

    PubMed

    Kodaira, Chise; Uchida, Shinya; Yamade, Mihoko; Nishino, Masafumi; Ikuma, Mutsuhiro; Namiki, Noriyuki; Sugimoto, Mitsushige; Watanabe, Hiroshi; Hishida, Akira; Furuta, Takahisa

    2012-03-01

    Aminopyrine is metabolized by cytochrome P450 (CYP) in the liver. The investigators evaluated influences of different PPIs on CYP activity as assessed by the [(13)C]-aminopyrine breath test ([(13)C]-ABT). Subjects were 15 healthy volunteers with different CYP2C19 status (5 rapid metabolizers [RMs], 5 intermediate metabolizers [IMs], and 5 poor metabolizers [PMs]). Breath samples were collected before and every 15 to 30 minutes for 3 hours after oral ingestion of [(13)C]-aminopyrine 100 mg on day 8 of each of the following regimens: control; omeprazole 20 mg and 80 mg, lansoprazole 30 mg, and rabeprazole 20 mg. Changes in carbon isotope ratios in carbon dioxide ((13)CO(2)/(12)CO(2)) in breath samples were measured by infrared spectrometry and expressed as delta-over-baseline (DOB) ratios (‰). Mean areas under the curve of DOB from 0 to 3 h (AUC(0-3h) of DOB) were significantly decreased by omeprazole 20 mg and lansoprazole 30 mg but not by rabeprazole 20 mg. Conversely, higher PPI dose (ie, omeprazole 80 mg) seemed to further decrease AUC(0-3h) of DOB in RMs but increased it in PMs. Omeprazole and lansoprazole at the standard doses inhibit CYP activity but rabeprazole does not, whereas high-dose omeprazole seems to induce CYPs.

  4. Exhaled breath condensate pH in mechanically ventilated patients.

    PubMed

    Nannini, L J; Quintana, R; Bagilet, D H; Druetta, M; Ramírez, M; Nieto, R; Guelman Greta, G

    2013-12-01

    In this prospective clinical trial we aimed to answer if spontaneous exhaled breath condensate (EBC) in the trap of the expiratory arm of the ventilator could replace EBC collected by coolant chamber standardized with Argon as an inert gas. Second, if EBC pH could predict ventilator associated pneumonia (VAP) and mortality. We included 34 critically ill patients (males = 26), aged = 54.85 ± 19.86 (mean ± SD) yrs, that required mechanical ventilation due to non-pulmonary direct cause (APACHE II score = 23.58 ± 14.7; PaO(2)/FiO(2) = 240.00 ± 98.29). ICU with 9 beds from a regional teaching hospital. The patients were followed up until development of VAP, successful weaning or death. There were significant differences between mean EBC pH from the 4 procedures with the exception of spontaneous EBC de-aerated with Argon (n = 79; 6.74 ± 0.28) and coolant chamber deaerated with Argon (n = 79; 6.70 ± 0.36; p = NS by Tukey's Multiple Comparison Test). However, none of the procedures were extrapolated between each other according to Bland & Altman method. The mean EBC pH from the trap without Argon was 6.50 ± 0.28. From the total of 34 patients, 22 survived and were discharged and 12 patients died in the ICU. Spontaneous EBC pH could not be extrapolated to EBC pH from coolant chamber and it did not change in subjects who dead, neither subject with VAP in comparison with baseline data. The lack of other biomarker in EBC and the lack of a control group determinate the need for further studies in this setting. Copyright © 2012 Elsevier España, S.L. and SEMICYUC. All rights reserved.

  5. Medical Diagnostic Breath Analysis by Cavity Ring Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Guss, Joseph S.; Metsälä, Markus; Halonen, Lauri

    2009-06-01

    Certain medical conditions give rise to the presence of chemicals in the bloodstream. These chemicals - known as biomarkers - may also be present in low concentrations in human breath. Cavity ring down spectroscopy possesses the requisite selectivity and sensitivity to detect such biomarkers in the congested spectrum of a breath sample. The ulcer-causing bacterium, Helicobacter pylori, is a prolific producer of the enzyme urease, which catalyses the breakdown of urea ((NH_2)_2CO) in the stomach as follows: (NH_2)_2CO + H_2O ⟶ CO_2 + 2NH_3 Currently, breath tests seeking altered carbon-isotope ratios in exhaled CO_2 after the ingestion of ^{13}C- or ^{14}C-labeled urea are used to diagnose H. pylori infection. We present recent results from an ongoing collaboration with Tampere Area University Hospital. The study involves 100 patients (both infected and uninfected) and concerns the possible correlation between the bacterial infection and breath ammonia. D. Y. Graham, P. D. Klein, D. J. Evans, Jr, D. G. Evans, L. C. Alpert, A. R. Opekun, T. W. Boutton, Lancet 1(8543), 1174-7 March 1987.

  6. Application of LaserBreath-001 for breath acetone measurement in subjects with diabetes mellitus

    NASA Astrophysics Data System (ADS)

    Wang, Zhennan; Sun, Meixiu; Chen, Zhuying; Zhao, Xiaomeng; Li, Yingxin; Wang, Chuji

    2016-11-01

    Breath acetone is a promising biomarker of diabetes mellitus. With an integrated standalone, on-site cavity ringdown breath acetone analyzer, LaserBreath-001, we tested breath samples from 23 type 1 diabetic (T1D) patients, 312 type 2 diabetic (T2D) patients, 52 healthy subjects. In the cross-sectional studies, the obtained breath acetone concentrations were higher in the diabetic subjects compared with those in the control group. No correlation between breath acetone and simultaneous BG was observed in the T1D, T2D, and healthy subjects. A moderate positive correlation between the mean individual breath acetone concentrations and the mean individual BG levels was observed in the 20 T1D patients without ketoacidosis. In a longitudinal study, the breath acetone concentrations in a T1D patient with ketoacidosis decreased significantly and remained stable during the 5-day hospitalization. The results from a relatively large number of subjects tested indicate that an elevated mean breath acetone concentration exists in diabetic patients in general. Although many physiological parameters affect breath acetone concentrations, fast (<1 min) and on site breath acetone measurement can be used for diabetic screening and management under a specifically controlled condition.

  7. 46 CFR 197.450 - Breathing gas tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... taken at the connection point to the distribution system— (1) Every 6 months; and (2) After every repair or modification. (b) Purchased supplies of breathing mixtures supplied to a diver are checked before... commencement of diving operations, at the umbilical or underwater breathing apparatus connection point for the...

  8. Procedures in the 13C octanoic acid breath test for measurement of gastric emptying: analysis using Bland-Altman methods.

    PubMed

    Clegg, Miriam E; Shafat, Amir

    2010-08-01

    The (13)C octanoic acid breath test (OBT) was first developed as an alternative method of measuring gastric emptying (GE) to scintigraphy. There has been much debate about the test duration and how often measurements need to be taken. This study aims to address these issues. For 78 GE tests using the (13)C OBT, GE lag phase (T(lag)) was calculated while sampling more frequently than the recommended every 15 min. Comparisons between T(lag) were completed using Bland-Altman plots. Similarly, 4 or 6 h test durations were assessed to establish if they yield the same GE half time (T(half)). From one volunteer, samples were taken every 1 min for the first 30 min and then every 15 min until 6 h. GE times were then calculated using different combinations of sampling times. Evidence of a visible T(lag) was also explored from this data. Findings indicated that taking samples every 5 min for the first 30 min instead of every 15 min did not change the GE T(lag) based on Bland-Altman plots. The correlation between these two methods was also high (r(2) = 0.9957). The findings showed that the difference between the two sampling durations 4 and 6 h was large and the correlation between the methods was low (r(2) = 0.8335). Samples taken at a rate of one breath per min indicated lack of a visible T(lag). Sampling for the (13)C OBT should be completed every 15 min for 6 h.

  9. Limited electromagnetic interference testing of evidential breath testers

    DOT National Transportation Integrated Search

    1983-05-06

    This report summarizes a limited test program conducted to determine the susceptibility of evidential breath testers (EBTs) to radio frequency interference (RFI). Several comprehensive test protocols were prepared based on procedures developed by the...

  10. Reliability of breath by breath spirometry and relative flow-time indices for pulmonary function testing in horses.

    PubMed

    Burnheim, K; Hughes, K J; Evans, D L; Raidal, S L

    2016-11-28

    Respiratory problems are common in horses, and are often diagnosed as a cause of poor athletic performance. Reliable, accurate and sensitive spirometric tests of airway function in resting horses would assist with the diagnosis of limitations to breathing and facilitate investigations of the effects of various treatments on breathing capacity. The evaluation of respiratory function in horses is challenging and suitable procedures are not widely available to equine practitioners. The determination of relative flow or flow-time measures is used in paediatric patients where compliance may limit conventional pulmonary function techniques. The aim of the current study was to characterise absolute and relative indices of respiratory function in healthy horses during eupnoea (tidal breathing) and carbon dioxide (CO 2 )-induced hyperpnoea (rebreathing) using a modified mask pneumotrachographic technique well suited to equine practice, and to evaluate the reliability of this technique over three consecutive days. Coefficients of variation, intra-class correlations, mean differences and 95% confidence intervals across all days of testing were established for each parameter. The technique provided absolute measures of respiratory function (respiratory rate, tidal volume, peak inspiratory and expiratory flows, time to peak flow) consistent with previous studies and there was no significant effect of day on any measure of respiratory function. Variability of measurements was decreased during hyperpnea caused by rebreathing CO 2 , but a number of relative flow-time variables demonstrated good agreement during eupnoeic respiration. The technique was well tolerated by horses and study findings suggest the technique is suitable for evaluation of respiratory function in horses. The use of relative flow-time variables provided reproducible (consistent) results, suggesting the technique may be of use for repeated measures studies in horses during tidal breathing or rebreathing.

  11. 49 CFR 40.277 - Are alcohol tests other than saliva or breath permitted under these regulations?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Are alcohol tests other than saliva or breath... Testing § 40.277 Are alcohol tests other than saliva or breath permitted under these regulations? No.... Only saliva or breath for screening tests and breath for confirmation tests using approved devices are...

  12. 49 CFR 40.277 - Are alcohol tests other than saliva or breath permitted under these regulations?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false Are alcohol tests other than saliva or breath... Testing § 40.277 Are alcohol tests other than saliva or breath permitted under these regulations? No.... Only saliva or breath for screening tests and breath for confirmation tests using approved devices are...

  13. Diagnostic accuracy of the 14C-urea breath test in Helicobacter pylori infections: a meta-analysis.

    PubMed

    Zhou, Qiaohui; Li, Ling; Ai, Yaowei; Pan, Zhihong; Guo, Mingwen; Han, Jingbo

    2017-01-01

    To summarize and appraise the available literature regarding the use of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspepsia and to calculate pooled diagnostic accuracy measures. We systematically searched the PubMed, EMBASE, Cochrane Library, Chinese Journals Full-text (CNKI) and CBMDisc databases to identify published data regarding the sensitivity, specificity, and other measures of diagnostic accuracy of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspeptic symptoms. Risk of bias was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies)-2 tool. Statistical analyses were performed using Meta-Disc 1.4 software and STATA. Eighteen studies met the inclusion criteria. Pooled results indicated that the  14 C-urea breath test showed a diagnostic sensitivity of 0.96 (95% CI 0.95 to 0.96) and specificity of 0.93 (95% CI 0.91 to 0.94). The positive like ratio (PLR) was 12.27 (95% CI 8.17 to 18.44), the negative like ratio (NLR) was 0.05 (95% CI 0.04 to 0.07), and the area under the curve was 0.985. The DOR was 294.95 (95% CI 178.37 to 487.70). The 14 C-urea breath test showed sufficient sensitivity and specificity for diagnosing Helicobacter pylori infection, but unexplained heterogeneity after meta-regression and several subgroup analyses remained. The UBT has high accuracy for diagnosing H. pylori infections in adult patients with dyspepsia. However, the reliability of these diagnostic meta-analytic estimates is limited by significant heterogeneity due to unknown factors.

  14. Results of the first semi-annual qualification testing of devices to measure breath alcohol

    DOT National Transportation Integrated Search

    1975-01-01

    Eight evidential breath testers were performance tested according to the Standard for Devices to Measure Breath Alcohol Federal Register, Vol 38, No. 212, November 5, 1973. In addition, a prototype breath tester not commercially available was tested....

  15. Performance of the 13C-urea breath test for the diagnosis of H. pylori infection using a substrate synthesized in Brazil: A preliminary study.

    PubMed

    Coelho, Luiz Gonzaga; Sant'Ana, Carlos Roberto; Oliveira, Ricardo Brandt de; Cezar, Raíra César E; Araujo, Aline Cordeiro Campos de; Silva, Raisa Cristina Teodoro da; Trindade, Osmar Reni; Coelho, Maria Clara; Ferrioli, Eduardo; Bendassolli, José Albertino

    2018-06-07

    The 13C-urea breath test is the main non-invasive test for the diagnosis of Helicobacter pylori infection. The availability of this test throughout the country is limited, mainly due to the difficulty in obtaining the labeled isotope from abroad. Recently, researchers from the Nuclear Energy Center in Agriculture at the University of São Paulo (CENA/USP) succeeded in synthesizing 13C-enriched urea for Helicobacter pylori diagnosis. The aim of the study was to compare the performance of the 13C-urea breath test using 13C-urea acquired abroad with that of a test using 13C-urea synthesized in Brazil. Sixty-four dyspeptic patients participated in the study (24 men and 40 women). Initially, the patients performed the 13C-urea breath test using the imported substrate (Euriso-Top, France). Seven to fourteen days later, all the patients repeated the test using the Brazilian substrate. The samples from both examinations were processed in an infrared isotope analyzer (IRIS, Wagner Analisen Technik, Germany), and all delta over baseline (DOB) [%] values above four were considered positive results. Twenty-seven patients (42%) exhibited negative results for Helicobacter pylori infection, and thirty-seven patients (58%) exhibited positive results when tested using the foreign substrate (gold standard). There was a 100% concordance regarding the presence or absence of infection when the gold standard results were compared with those obtained using the Brazilian substrate. Similar performance in the diagnosis of Helicobacter pylori infection was demonstrated when using the 13C-urea breath test with the Brazilian 13C-urea substrate and the test with the substrate produced abroad. This validation represents an important step toward increasing the availability of the 13C-urea breath test throughout the country, which will have a positive influence on the management of Helicobacter pylori infection.

  16. Measurement of breath acetone in patients referred for an oral glucose tolerance test.

    PubMed

    Andrews, Brian Terence; Denzer, Wolfgang; Hancock, Gus; Lunn, Dan; Peverall, Robert; Ritchie, Grant; Williams, Karen

    2018-04-12

    Breath acetone concentrations were measured in 141 subjects (aged 19-91 yrs, mean=59.11yrs standard deviation=12.99yrs), male and female, undergoing an oral glucose tolerance test (OGTT), having been referred to clinic on suspicion of type 2 diabetes. Breath samples were measured using an ion-molecule-reaction mass spectrometer, at the commencement of the OGTT, and after 1 and 2hrs. Subjects were asked to observe the normal routine before and during the OGTT, which includes an overnight fast and ingestion of 75g glucose at the beginning of the routine. Several groups of diagnosis were identified: type 2 Diabetes Mellitus positive (T2DM), n=22; impaired glucose intolerance (IGT), n=33; impaired fasting glucose (IFG), n=14; and reactive hypoglycaemia (RHG), n=5. The subjects with no diagnosis (i.e. normoglycaemia) were used as a control group, n=67. Distributions of breath acetone are presented for the different groups. There was no evidence of a direct relationship between blood glucose and acetone measurements at any time during the study (0hr: p=0.4482; 1hr: p=0.6854; and 2hr: p=0.1858). Nor were there significant differences between the measurements of breath acetone for the control group and the T2DM group (0hr: p=0.1759; 1hr: p=0.4521; and 2hr: p=0.7343). However, the ratio of breath acetone at 1hr to the initial breath acetone was found to be significantly different for the T2DM group compared to both the control and IGT groups (p=0.0189 and 0.011, respectively). The T2DM group was also found to be different in terms of ratio of breath acetone after 1hr to that at 2hrs during the OGTT. And was distinctive in that it showed a significant dependence upon the level of blood glucose at 2hrs (p=0.0146). We conclude that single measurements of the concentrations of breath acetone cannot be used as a potential screening diagnostic for T2DM diabetes in this cohort, but monitoring the evolution of breath acetone could open a non-invasive window to aid in the diagnosis

  17. Effects of breathing exercises on breathing patterns in obese and non-obese subjects.

    PubMed

    Olsén, M F; Lönroth, H; Bake, B

    1999-05-01

    Chest physiotherapy in connection with abdominal surgery includes different deep-breathing exercises to prevent post-operative pulmonary complications. The therapy is effective in preventing pulmonary complications, especially in high-risk patients such as obese persons. The mechanisms behind the effect is unclear, but part of the effect may be explained by the changes in breathing patterns. The aim of this study was therefore to describe and to analyse the breathing patterns in obese and non-obese subjects during three different breathing techniques frequently used in the treatment of post-operative patients. Twenty-one severely obese [body mass index (BMI) > 40] and 21 non-obese (BMI 19-25) subjects were studied. All persons denied having any lung disease and were non-smokers. The breathing techniques investigated were: deep breaths without any resistance (DB), positive expiratory pressure (PEP) with an airway resistance of approximately +15 cmH2O (1.5 kPa) during expiration, inspiratory resistance positive expiratory pressure (IR-PEP) with a pressure of approximately -10 cmH2O (-1.0 kPa) during inspiration. Expiratory resistance as for PEP. Volume against time was monitored while the subjects were sitting in a body plethysmograph. Variables for volume and flow during the breathing cycle were determined. Tidal volume and alveolar ventilation were highest during DB, and peak inspiratory volume was significantly higher than during PEP and IR-PEP in the group of obese subjects. The breathing cycles were prolonged in all techniques but were most prolonged in PEP and IR-PEP. The functional residual capacity (FRC) was significantly lower during DB than during PEP and IR-PEP in the group of obese subjects. FRC as determined within 2 min of finishing each breathing technique was identical to before the breathing manoeuvres.

  18. Significance of hydrogen breath tests in children with suspected carbohydrate malabsorption

    PubMed Central

    2014-01-01

    Background Hydrogen breath tests are noninvasive procedures frequently applied in the diagnostic workup of functional gastrointestinal disorders. Here, we review hydrogen breath test results and the occurrence of lactose, fructose and sorbitol malabsorption in pediatric patients; and determine the significance of the findings and the outcome of patients with carbohydrate malabsorption. Methods We included 206 children (88 male, 118 female, median age 10.7 years, range 3–18 years) with a total of 449 hydrogen breath tests (lactose, n = 161; fructose, n = 142; sorbitol, n = 146) into a retrospective analysis. Apart from test results, we documented symptoms, the therapeutic consequences of the test, the outcome and the overall satisfaction of the patients and families. Results In total, 204 (46%) of all breath tests were positive. Long-term follow-up data could be collected from 118 patients. Of 79 patients (67%) who were put on a diet reduced in lactose, fructose and/or sorbitol, the majority (92%, n = 73) reported the diet to be strict and only 13% (n = 10) had no response to diet. Most families (96%, n = 113) were satisfied by the test and the therapy. There were only 21 tests (5%) with a borderline result because the criteria for a positive result were only partially met. Conclusions Hydrogen breath tests can be helpful in the evaluation of children with gastrointestinal symptoms including functional intestinal disorders. If applied for a variety of carbohydrates but only where indicated, around two-third of all children have positive results. The therapeutic consequences are successfully relieving symptoms in the vast majority of patients. PMID:24575947

  19. Effect of DA-9701 on gastric emptying in a mouse model: assessment by ¹³C-octanoic acid breath test.

    PubMed

    Lim, Chul-Hyun; Choi, Myung-Gyu; Park, Hyeyeon; Baeg, Myong Ki; Park, Jae Myung

    2013-07-21

    To evaluate the effects of DA-9701 on the gastric emptying of a solid meal using the ¹³C-octanoic acid breath test in a mouse model. Male C57BL/6 mice aged > 8 wk and with body weights of 20-25 g were used in this study. The solid test meal consisted of 200 mg of egg yolk labeled with 1.5 L/g ¹³C-octanoic acid. The mice were placed in a 130 mL chamber flushed with air at a flow speed of 200 mL/min. Breath samples were collected for 6 h. The half-emptying time and lag phase were calculated using a modified power exponential model. To assess the reproducibility of the ¹³C-octanoic acid breath test, the breath test was performed two times at intervals of one week in ten mice without drug treatment. To assess the gastrokinetic effects of DA-9701, the breath test was performed three times in another twelve mice, with a randomized crossover sequence of three drug treatments: DA-9701 3 mg/kg, erythromycin 6 mg/kg, or saline. Each breath test was performed at an interval of one week. Repeatedly measured half gastric emptying time of ten mice without drug treatment showed 0.856 of the intraclass correlation coefficient for the half gastric emptying time (P = 0.004). The mean cumulative excretion curve for the ¹³C-octanoic acid breath test showed accelerated gastric emptying after DA-9701 treatment compared with the saline control (P = 0.028). The median half gastric emptying time after the DA-9701 treatment was significantly shorter than after the saline treatment [122.4 min (109.0-137.9 min) vs 134.5 min (128.4-167.0 min), respectively; P = 0.028] and similar to that after the erythromycin treatment [123.3 min (112.9-138.2 min)]. The lag phase, which was defined as the period taken to empty 15% of a meal, was significantly shorter after the DA-9701 treatment than after the saline treatment [48.1 min (44.6-57.1 min) vs 52.6 min (49.45-57.4 min), respectively; P = 0.049]. The novel prokinetic agent DA-9701 accelerated gastric emptying, assessed with repeated

  20. Lack of inhibitory effect of cimetidine on caffeine metabolism in children using the caffeine breath test

    PubMed Central

    Parker, A.C.; Pritchard, P.; Preston, T.; Dalzell, A.M.; Choonara, I.

    1997-01-01

    Aims To study the potential drug interaction between cimetidine and caffeine in a group of children who received cimetidine for gastritis. Methods The caffeine breath test was carried out prior to the administration of cimetidine and after 2–3 weeks therapy. The children (n=1) received 300–800 mg cimetidine daily (11–36 mg kg−1 day−1 ). Results There was no significant change in the 2h cumulative labelled CO2 following the administration of cimetidine (mean values 5.61% before and 4.87% during cimetidine; Student’s t-test P >0.2). Conclusions Cimetidine did not have an inhibitory effect on the metabolism of caffeine in this group of children studied. PMID:9159560

  1. Methodological implications in pH standardization of exhaled breath condensate.

    PubMed

    Hoffmeyer, F; Berresheim, H; Beine, A; Sucker, K; Brüning, T; Bünger, J

    2015-05-14

    The variable amount of dissolved carbon dioxide is one of the main confounding factors of exhaled breath condensate (EBC) pH measurements. There have been many attempts at identifying the optimal approach to displace CO2 as a way to gain reproducible and valid pH values in EBC samples. The aim of the present study was to assess the correlation of pH and pCO2 in untreated, neat EBC samples and, after deaeration, to reevaluate the standardization of CO2 as a means to obtain valid pH values. A further aim was to evaluate the impact of deaeration on the acid-base balance in EBC samples. EBC was collected from seven female and 31 male subjects. The pH and pCO2 values immediately determined in untreated, neat EBC samples were strongly correlated (rp = -0.723, p <  0.0001). This correlation was not observed after deaeration with argon (rs = 0.264, p = 0.109). Based on a regression function for the pH/pCO2 relationship, the calculated pH at a pCO2 of 5.33 kPa was 6.07 (IQR 5.99, 6.20). No significant difference was observed between the pH measured in neat EBC samples and those calculated after deaeration with regression function and measured neat pCO2. Our data suggest that pCO2 is the most important confounder of pH measurement in EBC samples and, when adjusting for pCO2, the acid-base balance of EBC samples is not significantly influenced by the process of deaeration. Furthermore, measurement with a blood-gas analyzer and standardization of pH for pCO2 allows sensitive assaying of EBC samples. Therefore, this method provides a basis for detection of even small changes in airway pH due to inhalative exposure or respiratory disease.

  2. Exercise changes volatiles in exhaled breath assessed by an electronic nose.

    PubMed

    Bikov, A; Lazar, Zs; Schandl, K; Antus, B M; Losonczy, G; Horvath, Ildiko

    2011-09-01

    Exercise-caused metabolic changes can be followed by monitoring exhaled volatiles; however it has not been previously reported if a spectrum of exhaled gases is modified after physical challenge. We have hypothesized that changes in volatile molecules assessed by an electronic nose may be the reason for the alkalization of the exhaled breath condensate (EBC) fluid following physical exercise.Ten healthy young subjects performed a 6-minute running test. Exhaled breath samples pre-exercise and post-exercise (0 min, 15 min, 30 min and 60 min) were collected for volatile pattern ("smellprint") determination and pH measurements (at 5.33 kPa CO2), respectively. Exhaled breath smellprints were analyzed using principal component analysis and were related to EBC pH.Smellprints (p=0.04) and EBC pH (p=0.01) were altered during exercise challenge. Compared to pre-exercise values, smellprints and pH differed at 15 min, 30 min and 60 min following exercise (p<0.05), while no difference was found at 0 min post-exercise. In addition, a significant correlation was found between volatile pattern of exhaled breath and EBC pH (p=0.01, r=-0.34).Physical exercise changes the pattern of exhaled volatiles together with an increase in pH of breath. Changes in volatiles may be responsible for increase in EBC pH.

  3. Prediction of heart transplant rejection with a breath test for markers of oxidative stress.

    PubMed

    Phillips, Michael; Boehmer, John P; Cataneo, Renee N; Cheema, Taseer; Eisen, Howard J; Fallon, John T; Fisher, Peter E; Gass, Alan; Greenberg, Joel; Kobashigawa, Jon; Mancini, Donna; Rayburn, Barry; Zucker, Mark J

    2004-12-15

    The Heart Allograft Rejection: Detection with Breath Alkanes in Low Levels study evaluated a breath test for oxidative stress in heart transplant recipients, and we report here a mathematical model predicting the probability of grade 3 rejection. The breath test divided the heart transplant recipients into 3 groups: positive for grade 3 rejection, negative for grade 3 rejection, and intermediate. The test was 100% sensitive for grade 3 heart transplant rejection when the p value was >/=0.98, and 100% specific when the p value was breath test determined the probability of grade 3 rejection and the predictive value of the result.

  4. SU-E-T-326: The Oxygen Saturation (SO2) and Breath-Holding Time Variation Applied Active Breathing Control (ABC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, G; Yin, Y

    Purpose: To study the oxygen saturation (SO2) and breath-holding time variation applied active breathing control (ABC) in radiotherapy of tumor. Methods: 24 volunteers were involved in our trials, and they all did breath-holding motion assisted by ELEKTA Active Breathing Coordinator 2.0 for 10 times respectively. And the patient monitor was used to observe the oxygen saturation (SO2) variation. The variation of SO2, and length of breath-holding time and the time for recovering to the initial value of SO2 were recorded and analyzed. Results: (1) The volunteers were divided into two groups according to the SO2 variation in breath-holding: A group,more » 14 cases whose SO2 reduction were more than 2% (initial value was 97% to 99%, while termination value was 91% to 96%); B group, 10 cases were less than 2% in breath-holding without inhaling oxygen. (2) The interfraction breath holding time varied from 8 to 20s for A group compared to the first breath-holding time, and for B group varied from 4 to 14s. (3) The breathing holding time of B group prolonged mean 8s, compared to A group. (4) The time for restoring to the initial value of SO2 was from 10s to 30s. And the breath-holding time shortened obviously for patients whose SO2 did not recover to normal. Conclusion: It is very obvious that the SO2 reduction in breath-holding associated with ABC for partial people. It is necessary to check the SO2 variation in breath training, and enough time should be given to recover SO2.« less

  5. Breath biomarkers in toxicology.

    PubMed

    Pleil, Joachim D

    2016-11-01

    Exhaled breath has joined blood and urine as a valuable resource for sampling and analyzing biomarkers in human media for assessing exposure, uptake metabolism, and elimination of toxic chemicals. This article focuses current use of exhaled gas, aerosols, and vapor in human breath, the methods for collection, and ultimately the use of the resulting data. Some advantages of breath are the noninvasive and self-administered nature of collection, the essentially inexhaustible supply, and that breath sampling does not produce potentially infectious waste such as needles, wipes, bandages, and glassware. In contrast to blood and urine, breath samples can be collected on demand in rapid succession and so allow toxicokinetic observations of uptake and elimination in any time frame. Furthermore, new technologies now allow capturing condensed breath vapor directly, or just the aerosol fraction alone, to gain access to inorganic species, lung pH, proteins and protein fragments, cellular DNA, and whole microorganisms from the pulmonary microbiome. Future applications are discussed, especially the use of isotopically labeled probes, non-targeted (discovery) analysis, cellular level toxicity testing, and ultimately assessing "crowd breath" of groups of people and the relation to dose of airborne and other environmental chemicals at the population level.

  6. Validation of a new mixing chamber system for breath-by-breath indirect calorimetry.

    PubMed

    Kim, Do-Yeon; Robergs, Robert Andrew

    2012-02-01

    Limited validation research exists for applications of breath-by-breath systems of expired gas analysis indirect calorimetry (EGAIC) during exercise. We developed improved hardware and software for breath-by-breath indirect calorimetry (NEW) and validated this system as well as a commercial system (COM) against 2 methods: (i) mechanical ventilation with known calibration gas, and (ii) human subjects testing for 5 min each at rest and cycle ergometer exercise at 100 and 175 W. Mechanical calibration consisted of medical grade and certified calibration gas ((4.95% CO(2), 12.01% O(2), balance N(2)), room air (20.95% O(2), 0.03% CO(2), balance N(2)), and 100% nitrogen), and an air flow turbine calibrated with a 3-L calibration syringe. Ventilation was mimicked manually using complete 3-L calibration syringe manouvers at a rate of 10·min(-1) from a Douglas bag reservoir of calibration gas. The testing of human subjects was completed in a counterbalanced sequence based on 5 repeated tests of all conditions for a single subject. Rest periods of 5 and 10 min followed the 100 and 175 W conditions, respectively. COM and NEW had similar accuracy when tested with known ventilation and gas fractions. However, during human subjects testing COM significantly under-measured carbon dioxide gas fractions, over-measured oxygen gas fractions and minute ventilation, and resulted in errors to each of oxygen uptake, carbon dioxide output, and respiratory exchange ratio. These discrepant findings reveal that controlled ventilation and gas fractions are insufficient to validate breath-by-breath, and perhaps even time-averaged, systems of EGAIC. The errors of the COM system reveal the need for concern over the validity of commercial systems of EGAIC.

  7. News from the Breath Analysis Summit 2011.

    PubMed

    Corradi, Massimo; Mutti, Antonio

    2012-06-01

    (oxygen, nitrogen, water vapour and CO(2)) in patient respiratory monitoring have served as a platform for technological growth in clinical breath-testing applications. A few exhaled breath tests have demonstrated clinical utility and are in widespread use, and several FDA-approved devices are available. These widely used exhaled breath tests include detection of blood alcohol concentration and exhaled CO(2). Other clinical applications of exhaled breath analysis include testing for H. pylori infection, lactose intolerance, heart transplant rejection and, more recently, monitoring of airway inflammation by means of exhaled NO. Examination of exhaled breath has the potential to change the existing routine approaches in human medicine. The rapidly developing new analytical and computer technologies along with novel, unorthodox ideas are prerequisites for future advances in this field. Scientists who participated in the Breath Analysis Summit 2011 were invited to submit a full length paper to the Journal of Breath Research and this issue includes eight articles which describe the different applications of breath analysis. We thank all the authors for their valuable contribution and we trust that this collection will provide useful information and an update to this rapidly evolving field, giving an example of integration among scientists who address the same topic-breath analysis-from different and complementary perspectives, from basic to clinical research.

  8. Effect of air breathing on acid-base and ion regulation after exhaustive exercise and during low pH exposure in the bowfin, Amia calva.

    PubMed

    Gonzalez, R J; Milligan, L; Pagnotta, A; McDonald, D G

    2001-01-01

    To explore a potential conflict between air breathing and acid-base regulation in the bowfin (Amia calva), we examined how individuals with access to air differed from fish without air access in their response to acidosis. After exhaustive exercise, bowfin with access to air recovered significantly more slowly from the acidosis than fish without air access. While arterial blood pH (pH(a)) of fish without air access recovered to resting levels by 8 h, pH(a) was still significantly depressed in fish having access to air. In addition, Pco(2) was slightly more elevated in fish having air access than those without it. Fish with access to air still had a significant metabolic acid load after 8-h recovery, while those without air access completely cleared the load within 4 h. These results suggest that bowfin with access to air were breathing air and, consequently, were less able to excrete CO(2) and H(+) and experienced a delayed recovery. In contrast, during exposure to low pH, air breathing seemed to have a protective effect on acid-base status in bowfin. During exposure to low pH water, bowfin with access to air developed a much milder acidosis than bowfin without air access. The more severe acidosis in fish without air access was caused by an increased rate of lactic acid production. It appears that enhanced O(2) delivery allowed air-breathing bowfin to avoid acidosis-induced anaerobic metabolism and lactic acid production. In addition, during low pH exposure, plasma Na(+) and Cl(-) concentrations of fish without air access fell slightly more rapidly than those in fish with air access, indicating that the branchial ventilatory changes associated with air breathing limited, to some degree, ion losses associated with low pH exposure.

  9. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Breath-alcohol test system. 862.3050 Section 862.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...

  10. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Breath-alcohol test system. 862.3050 Section 862.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...

  11. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Breath-alcohol test system. 862.3050 Section 862.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862...

  12. Air-Breathing Rocket Engine Test

    NASA Technical Reports Server (NTRS)

    2000-01-01

    This photograph depicts an air-breathing rocket engine that completed an hour or 3,600 seconds of testing at the General Applied Sciences Laboratory in Ronkonkoma, New York. Referred to as ARGO by its design team, the engine is named after the mythological Greek ship that bore Jason and the Argonauts on their epic voyage of discovery. Air-breathing engines, known as rocket based, combined-cycle engines, get their initial take-off power from specially designed rockets, called air-augmented rockets, that boost performance about 15 percent over conventional rockets. When the vehicle's velocity reaches twice the speed of sound, the rockets are turned off and the engine relies totally on oxygen in the atmosphere to burn hydrogen fuel, as opposed to a rocket that must carry its own oxygen, thus reducing weight and flight costs. Once the vehicle has accelerated to about 10 times the speed of sound, the engine converts to a conventional rocket-powered system to propel the craft into orbit or sustain it to suborbital flight speed. NASA's Advanced SpaceTransportation Program at Marshall Space Flight Center, along with several industry partners and collegiate forces, is developing this technology to make space transportation affordable for everyone from business travelers to tourists. The goal is to reduce launch costs from today's price tag of $10,000 per pound to only hundreds of dollars per pound. NASA's series of hypersonic flight demonstrators currently include three air-breathing vehicles: the X-43A, X-43B and X-43C.

  13. BreathDx - molecular analysis of exhaled breath as a diagnostic test for ventilator-associated pneumonia: protocol for a European multicentre observational study.

    PubMed

    van Oort, Pouline M P; Nijsen, Tamara; Weda, Hans; Knobel, Hugo; Dark, Paul; Felton, Timothy; Rattray, Nicholas J W; Lawal, Oluwasola; Ahmed, Waqar; Portsmouth, Craig; Sterk, Peter J; Schultz, Marcus J; Zakharkina, Tetyana; Artigas, Antonio; Povoa, Pedro; Martin-Loeches, Ignacio; Fowler, Stephen J; Bos, Lieuwe D J

    2017-01-03

    The diagnosis of ventilator-associated pneumonia (VAP) remains time-consuming and costly, the clinical tools lack specificity and a bedside test to exclude infection in suspected patients is unavailable. Breath contains hundreds to thousands of volatile organic compounds (VOCs) that result from host and microbial metabolism as well as the environment. The present study aims to use breath VOC analysis to develop a model that can discriminate between patients who have positive cultures and who have negative cultures with a high sensitivity. The Molecular Analysis of Exhaled Breath as Diagnostic Test for Ventilator-Associated Pneumonia (BreathDx) study is a multicentre observational study. Breath and bronchial lavage samples will be collected from 100 and 53 intubated and ventilated patients suspected of VAP. Breath will be analysed using Thermal Desorption - Gas Chromatography - Mass Spectrometry (TD-GC-MS). The primary endpoint is the accuracy of cross-validated prediction for positive respiratory cultures in patients that are suspected of VAP, with a sensitivity of at least 99% (high negative predictive value). To our knowledge, BreathDx is the first study powered to investigate whether molecular analysis of breath can be used to classify suspected VAP patients with and without positive microbiological cultures with 99% sensitivity. UKCRN ID number 19086, registered May 2015; as well as registration at www.trialregister.nl under the acronym 'BreathDx' with trial ID number NTR 6114 (retrospectively registered on 28 October 2016).

  14. Application of drug testing using exhaled breath for compliance monitoring of drug addicts in treatment.

    PubMed

    Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof

    2015-04-01

    Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.

  15. 13C-Mixed Triglyceride Breath Test and Fecal Elastase as an Indirect Pancreatic Function Test in Cystic Fibrosis Infants.

    PubMed

    Kent, Dorothea Stark; Remer, Thomas; Blumenthal, Caron; Hunt, Sharon; Simonds, Sharon; Egert, Sarah; Gaskin, Kevin J

    2018-05-01

    The 'gold standard' test for the indirect determination of pancreatic function status in infants with cystic fibrosis (CF), the 72-hour fecal fat excretion test, is likely to become obsolete in the near future. Alternative indirect pancreatic function tests with sufficient sensitivity and specificity to determine pancreatic phenotype need further evaluation in CF infants. Evaluation of the clinical utility of both the noninvasive, nonradioactive C-mixed triglyceride (MTG) breath test and fecal elastase-1 (FE1) in comparison with the 72-hour fecal fat assessment in infants with CF. C-MTG breath test and the monoclonal and polyclonal FE1 assessment in stool was compared with the 72-hour fecal fat assessment in 24 infants with CF. Oral pancreatic enzyme substitution (PERT; if already commenced) was stopped before the tests. Sensitivity rates between 82% and 100% for CF patients with pancreatic insufficiency assessed by both the C-MTG breath test and the FE1 tests proved to be high and promising. The C-MTG breath test (31%-38%) as well as both FE1 tests assessed by the monoclonal (46%-54%) and the polyclonal (45%) ELISA kits, however, showed unacceptably low-sensitivity rates for the detection of pancreatic-sufficient CF patients in the present study. The C-MTG breath test with nondispersive infrared spectroscopy (NDIRS) technique, as well as both FE1 tests, are not alternatives to the fecal fat balance test for the evaluation of pancreatic function in CF infants during the first year of life.

  16. Deep breathing exercises performed 2 months following cardiac surgery: a randomized controlled trial.

    PubMed

    Westerdahl, Elisabeth; Urell, Charlotte; Jonsson, Marcus; Bryngelsson, Ing-Liss; Hedenström, Hans; Emtner, Margareta

    2014-01-01

    Postoperative breathing exercises are recommended to cardiac surgery patients. Instructions concerning how long patients should continue exercises after discharge vary, and the significance of treatment needs to be determined. Our aim was to assess the effects of home-based deep breathing exercises performed with a positive expiratory pressure device for 2 months following cardiac surgery. The study design was a prospective, single-blinded, parallel-group, randomized trial. Patients performing breathing exercises 2 months after cardiac surgery (n = 159) were compared with a control group (n = 154) performing no breathing exercises after discharge. The intervention consisted of 30 slow deep breaths performed with a positive expiratory pressure device (10-15 cm H2O), 5 times a day, during the first 2 months after surgery. The outcomes were lung function measurements, oxygen saturation, thoracic excursion mobility, subjective perception of breathing and pain, patient-perceived quality of recovery (40-Item Quality of Recovery score), health-related quality of life (36-Item Short Form Health Survey), and self-reported respiratory tract infection/pneumonia and antibiotic treatment. Two months postoperatively, the patients had significantly reduced lung function, with a mean decrease in forced expiratory volume in 1 second to 93 ± 12% (P< .001) of preoperative values. Oxygenation had returned to preoperative values, and 5 of 8 aspects in the 36-Item Short Form Health Survey were improved compared with preoperative values (P< .01). There were no significant differences between the groups in any of the measured outcomes. No significant differences in lung function, subjective perceptions, or quality of life were found between patients performing home-based deep breathing exercises and control patients 2 months after cardiac surgery.

  17. Use of the single-breath method of estimating cardiac output during exercise-stress testing.

    NASA Technical Reports Server (NTRS)

    Buderer, M. C.; Rummel, J. A.; Sawin, C. F.; Mauldin, D. G.

    1973-01-01

    The single-breath cardiac output measurement technique of Kim et al. (1966) has been modified for use in obtaining cardiac output measurements during exercise-stress tests on Apollo astronauts. The modifications involve the use of a respiratory mass spectrometer for data acquisition and a digital computer program for data analysis. The variation of the modified method for triplicate steady-state cardiac output measurements was plus or minus 1 liter/min. The combined physiological and methodological variation seen during a set of three exercise tests on a series of subjects was 1 to 2.5 liter/min. Comparison of the modified method with the direct Fick technique showed that although the single-breath values were consistently low, the scatter of data was small and the correlation between the two methods was high. Possible reasons for the low single-breath cardiac output values are discussed.

  18. Performance of acidified 14C-urea capsule breath test during pantoprazole and ranitidine treatment.

    PubMed

    Oztürk, Emel; Yeşilova, Zeki; Ilgan, Seyfettin; Ozgüven, Mehmet; Dağalp, Kemal

    2009-07-01

    Urea breath test (UBT) results could be false negative in patients taking antisecretory drugs. This effect would be prevented by citric acid administration during UBT. We prospectively investigated whether acidified 14C-urea capsule prevents false negative UBT results in patients taking antisecretory drugs and show interference with the duration of medications. Sixty Helicobacter pylori positive patients were included. Pantoprazole (40 mg/day) was given to 27 patients for 28 days and ranitidine (300 mg. o.d.) to 33 patients for 60 days. Urea breath tests were repeated on days 14 and 28 in both groups and on day 60 in the ranitidine group. The baseline mean breath counts of two groups did not show any significant difference. Pantoprazole led to a significant decrease in mean breath counts on day 14 (P < 0.005). Six of 27 and 3 of 25 patients taking pantoprazole developed negative or equivocal UBT results on days 14 and 28, respectively. Two of 32, 2 of 32 and 3 of 21 patients taking ranitidine developed negative or equivocal UBT results on days 14, 28 and 60, respectively. The use of acidified 14C-urea capsule did not prevent false negative UBT results in patients taking pantoprazole and ranitidine, and the duration of medication does not affect the test results.

  19. Breath test refusals

    DOT National Transportation Integrated Search

    2007-11-01

    The National Highway Traffic Safety Administration has found that the percentage of people who refuse to provide breath samples when arrested for Driving While Intoxicated (DWI) varies considerably across States, and this creates a concern in the cri...

  20. Modified Helicobacter test using a new test meal and a 13C-urea breath test in Helicobacter pylori positive and negative dyspepsia patients on proton pump inhibitors.

    PubMed

    Tepeš, Bojan; Malfertheiner, Peter; Labenz, Joachim; Aygen, Sitke

    2017-08-28

    To determine the sensitivity and specificity of the 13 C-urea breath test (UBT) in patients taking proton pump inhibitors (PPIs), using a new test meal Refex. One hundred and fourteen consecutive patients with dyspepsia, 53 Helicobacter pylori ( H. pylori ) positive, 49 H. pylori negative, were included in the study. The patients were then given esomeprazole 40 mg for 29 consecutive days, and the 13 C-UBT with the new test meal was performed the next morning. The sensitivity of the 13 C-UBT with a cut off 2.5‰ was 92.45% (95%CI: 81.79%-97.91%) by per-protocol (PP) analysis and 78.13% (95%CI: 66.03%-87.49%) by intention-to-treat (ITT) analysis. The specificity of the 13 C-UBT test was 96.00% in the ITT population (95%CI: 86.29%-99.51%) and 97.96% in the PP population (95%CI: 89.15%-99.95%). The new test meal based 13 C-UBT is highly accurate in patients on PPIs and can be used in those unable to stop their PPI treatment.

  1. Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing.

    PubMed

    Donaldsson, Snorri; Falk, Markus; Jonsson, Baldvin; Drevhammar, Thomas

    2015-01-01

    The ability to determine airflow during nasal CPAP (NCPAP) treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing. Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically. The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance. The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates.

  2. [Examination of gastric emptying rate by means of 13C-octanoic acid breath test. Methods of the test for adults and results of the investigation of healthy volunteers].

    PubMed

    Bures, J; Kopácová, M; Vorísek, V; Bukac, J; Neumann, D; Rejchrt, S; Pozler, O; Douda, T; Zivný, P; Palicka, V

    2005-01-01

    13C-octanoic acid breath test (13C-OABT) is a simple, safe and non-invasive technique for measuring gastric emptying. However, the method has not been standardized yet. Aim of the study was to work up, introduce and evaluate our own method of the 13C-OABT for adults. Ten healthy volunteers entered the study (5 men, 5 women, mean age 32 years, 50 % Helicobacter pylori positive). Standard test meals (with 100 mg 13C-sodium octanoate) were used three times within 3 weeks. The same solid meal (1,178 kJ) for Tests 1 and 2 contained scrambled egg (+ 3 g oil), white bread (40 g), butter (10 g) and distilled water (200 ml). Semi-solid meal (1,020 kJ) for Test 3 contained milk pudding (200 g) and distilled water (200 ml). Duplicate breath samples were obtained before and every 15 minutes after eating the test meal during 255 minutes. Altogether 1,080 breath samples were analysed twice (isotope ratio mass spectrometry, AP2003 Analytical Precision, UK). To assess the half-life of elimination (t1/2 E), we modelled the process of elimination with the incomplete gamma-function, which has a convenient form for the empiric plotting of breath test data. Mean t1/2E was 136+/-10 minutes (Test 1), 134+/-14 (Test 2) and 123+/-16 minutes (Test 3). Clinical reproducibility of 13C-OABT in particular persons was 98.2% (18 breath samples series), 90.8 % (15 samples) and 87.1% (9 breath samples series). There was a significant correlation between Test 1 and Test 2 results (r=0.887, p<0.0001). Mean difference of duplicate breath sample analysis was 1.460 % (in 540 pairs), mean baseline one-day analysis difference was 0.0982 (99.9274% accuracy). In healthy volunteers, normal range of t1/2E is 110-160 minutes for solids and 91-155 minutes for semisolid test meal. Using our own computed mean time of intermediate metabolism of 13C-octanoic acid (76.5+/-7.5 minutes), gastric emptying half-time is 33.5-83.5 minutes for solids and 14.5-78.5 minutes for semisolid test meal in healthy volunteers. The

  3. A decrease in nasal CO2 stimulates breathing in the tegu lizard.

    PubMed

    Coates, E L; Furilla, R A; Ballam, G O; Bartlett, D

    1991-10-01

    Tegu lizards decrease ventilatory frequency (f) when constant CO2, as low as 0.4%, is delivered to the nasal cavities. In contrast, CO2, as high as 6%, pulsed into the nasal cavities during the expiratory phase of the breathing cycle does not alter f. The purpose of the present study was to investigate further the effect of nasal CO2 pattern on f in tegu lizards. Specifically, we tested: (1) whether f was affected by CO2 delivered to the nasal cavities during the inspiratory phase of the breathing cycle, and (2) whether pulsed decreases in nasal CO2 from 4% to 2% and from 4% to 0% would remove the f inhibition caused by constant nasal CO2. Ventilation was measured using a pneumotachograph and pressure transducer in-line with an endotracheal T-tube inserted through the glottis. CO2 was delivered to the nasal cavities through small tubes inserted into the external nares. Ventilatory frequency was not significantly altered when 4% CO2 was pulsed into the nasal cavities during inspiration. Dropping the CO2 in the nasal cavities from 4% to 0% at either 15 cycles/min (0.25 Hz) or for one cycle stimulated breathing. There was no significant difference between the f response to a drop in CO2 from 4% to 0% and that to a drop in CO2 from 4% to 2%. The failure to link the phasic CO2 ventilatory response to a phase in the respiratory cycle indicates that the nasal CO2 receptors do not participate in the breath-by-breath regulation of breathing in these lizards. The observation that small decreases in nasal CO2 abolished the f inhibition caused by constant nasal CO2 provides further evidence for the ability of the nasal CO2 receptors to distinguish between pulsed and constant CO2.

  4. Drinking influences exhaled breath condensate acidity.

    PubMed

    Kullmann, Tamás; Barta, Imre; Antus, Balázs; Horváth, Ildikó

    2008-01-01

    Exhaled breath condensate analysis is a developing method for investigating airway pathology. Impact of food and drink on breath condensate composition has not been systematically addressed. The aim of the study was to follow exhaled breath condensate pH after drinking an acidic and a neutral beverage. Breath condensate, capillary blood, and urine of 12 healthy volunteers were collected before and after drinking either 1 l of coke or 1 l of mineral water. The pH of each sample was determined with a blood gas analyzer. The mean difference between the pH of two breath condensate samples collected within 15 min before drinking was 0.13+/-0.03. Condensate pH decreased significantly from 6.29+/-0.02 to 6.24+/-0.02 (p<0.03) after drinking coke and from 6.37+/-0.03 to 6.22+/-0.04 (p<0.003) after drinking water. Drinking coke induced significant changes in blood and urine pH as well. Drinking influences exhaled breath condensate composition and may contribute to the variability of exhaled breath condensate pH.

  5. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...

  6. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...

  7. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...

  8. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Breath nitric oxide test system. 862.3080 Section 862.3080 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test...

  9. Lactose (mal)digestion evaluated by the 13C-lactose digestion test.

    PubMed

    Vonk, R J; Lin, Y; Koetse, H A; Huang, C; Zeng, G; Elzinga, H; Antoine, J; Stellaard, F

    2000-02-01

    The prevalence of genetically determined lactase nonpersistence is based on the results of the lactose H2 breath test. This test, however, is an indirect test, which might lead to misinterpretation. We determined lactase activity in healthy Chinese and Dutch students using a novel 13C-lactose digestion test. The cut-off value of this test was established in a Chinese population with a homogenous genetic background of lactase nonpersistence and was compared with the results obtained in a Caucasian population. Twenty-five grams of a 13C-lactose solution was consumed by 12 known H2-positive and 5 H2-negative Chinese students and 48 Dutch students and, subsequently, 13C-glucose concentration in plasma and H2 excretion in breath were measured. A similar 13C-glucose response curve was found in all Chinese students. The mean response curve in the Dutch students was more pronounced (P < 0.01). The 1 h (peak) plasma 13C-glucose concentration was the best discriminator between lactose digesting and maldigesting subjects. The cut-off level of 2 mmol L-1 13C-glucose in plasma was defined in the H2-positive Chinese students group. Based on the 13C-glucose response the prevalence of lactose maldigestion in the Dutch subjects was 25%; based on the lactose H2 breath test 17%. Using the 13C-lactose digestion test the results demonstrate a higher prevalence of lactose maldigestion in a Caucasian population than indicated by the results of the H2 breath test. A moderate increase in the plasma 13C-glucose concentration after consumption of 13C-lactose in the young adult Chinese subjects indicates a residual lactase activity in that age group, even when a positive H2 breath test result is obtained. These results indicate that the 13C-glucose concentration in plasma more accurately reflects the small intestinal lactose digestion capacity than the lactose H2 breath test.

  10. Does postprandial itopride intake affect the rate of gastric emptying? A crossover study using the continuous real time 13C breath test (BreathID system).

    PubMed

    Nonaka, Takashi; Kessoku, Takaomi; Ogawa, Yuji; Yanagisawa, Shogo; Shiba, Tadahiko; Sahaguchi, Takashi; Atsukawa, Kazuhiro; Takahashi, Hisao; Sekino, Yusuke; Iida, Hiroshi; Hosono, Kunihiro; Endo, Hiroki; Sakamoto, Yasunari; Koide, Tomoko; Takahashi, Hirokazu; Tokoro, Chikako; Abe, Yasunobu; Maeda, Shin; Nakajima, Atsushi; Inamori, Masahiko

    2011-01-01

    The aim of this study was to determine whether oral Itopride hydrochloride (itopride) intake might have any effect on the rate of gastric emptying, using a novel non-invasive technique for measuring the rate of gastric emptying, namely, the continuous real time 13C breath test (BreathID system: Exalenz Bioscience Ltd., Israel). Eight healthy male volunteers participated in this randomized, two-way crossover study. The subjects fasted overnight and were randomly assigned to receive 50mg itopride following a test meal (200 kcal per 200mL, containing 100mg 13C acetate), or the test meal alone. Under both conditions, gastric emptying was monitored for 4 hours after administration of the test meal by the 13C-acetic acid breath test performed continually using the BreathID system. Using Oridion Research Software (beta version), the time required for emptying of 50% of the labeled meal (T 1/2), the analog to the scintigraphy lag time for 10% emptying of the labeled meal (T lag), the gastric emptying coefficient (GEC), and the regression-estimated constants (beta and kappa) were calculated. The parameters measured under the two conditions were compared using the Wilcoxon's signed-rank test. No significant differences in the calculated parameters, namely, the T 1/2, T lag, GEC, beta or kappa, were observed between the two test conditions, namely, administration of a test meal+itopride and administration of the test meal alone. The present study revealed that postprandial itopride intake had no significant influence on the rate of gastric emptying. Recently, several studies have shown that itopride may be effective in the treatment of patients with functional dyspepsia. Our results suggest that the efficacy of itopride in patients with functional dyspepsia may be based on its effect of improving functions other than the rate of gastric emptying, such as the activities at neuronal sites, brain-gut correlation, visceral hypersensitivity, gastric accommodation and distension

  11. Breath-hold time during cold water immersion: effects of habituation with psychological training.

    PubMed

    Barwood, Martin J; Datta, Avijit K; Thelwell, Richard C; Tipton, Michael J

    2007-11-01

    The loss of the conscious control of respiration on whole body cold water immersion (CWI) can result in the aspiration of water and drowning. Repeated CWI reduces the respiratory drive evoked by CWI and should prolong breath-hold time on CWI (BHmax(CWI)). Psychological skills training (PST) can also increase BHmax(CWI) by improving the ability of individuals to consciously suppress the drive to breathe. This study tested the hypothesis that combining PST and repeated CWI would extend BHmax(CWI) beyond that seen following only repeated CWI. There were 20 male subjects who completed two 2.5-min, head-out breath-hold CWI (BH1 and BH2) in water at 12 degrees C. Following BH1, subjects were matched on BHmax(CWI) and allocated to a habituation (HAB) group or a habituation plus PST group (H+PST). Between BH1 and BH2 both experimental groups undertook five 2.5-min CWI on separate days, during which they breathed freely. The H+PST also received psychological training to help tolerate cold and suppress the drive to breathe on immersion to extend BHmax(CWI). During BH1, mean BHmax(CWI) (+/- SD) in the HAB group was 22.00 (10.33) s and 22.38 (10.65) s in the H+PST. After the five free-breathing CWI, both groups had a longer BHmax(CWI) in BH2. The HAB group improved by 14.13 (20.21) s, an increase of 73%. H+PST improved by 26.86 (24.70) s, a 120% increase. No significant differences were identified between the groups. Habituation significantly increases BHmax on CWI, the addition of PST did not result in statistically significant improvements in BHmax(CWI), but may have practical significance.

  12. Breath test refusals and DWI prosecution : traffic tech.

    DOT National Transportation Integrated Search

    2012-08-01

    There are typically about 1.4 million DWI (driving while : impaired) arrests each year in the United States. An officers : request to a driver for a breath (or blood, or urine) test is an : important part of the arrest process. The percentage of d...

  13. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  14. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  15. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  16. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  17. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  18. Breath carbon stable isotope ratios identify changes in energy balance and substrate utilization in humans.

    PubMed

    Whigham, L D; Butz, D E; Johnson, L K; Schoeller, D A; Abbott, D H; Porter, W P; Cook, M E

    2014-09-01

    Rapid detection of shifts in substrate utilization and energy balance would provide a compelling biofeedback tool for individuals attempting weight loss. As a proof of concept, we tested whether the natural abundance of exhaled carbon stable isotope ratios (breath δ(13)C) reflects shifts between negative and positive energy balance. Volunteers (n=5) consumed a 40% energy-restricted diet for 6 days followed by 50% excess on day 7. Breath was sampled immediately before and 1 h and 2h after breakfast, lunch and dinner. Exhaled breath δ(13)C values were measured by cavity ring-down spectroscopy. Using repeated measures analysis of variance (ANOVA) followed by Dunnett's contrasts, pre-breakfast breath values on days 2-6 were compared with day 1, and postprandial day 7 time points were compared with pre-breakfast day 7. Energy restriction diminished pre-breakfast breath δ(13)C by day 3 (P<0.05). On day 7, increased energy intake was first detected immediately before dinner (-23.8±0.6 vs -21.9±0.7‰, P=0.002 (means±s.d.)), and breath δ(13)C remained elevated at least 2h post dinner. In conclusion, when shifting between negative and positive energy balance, breath δ(13)C showed anticipated isotopic changes. Although additional research is needed to determine specificity and repeatability, this method may provide a biomarker for marked increases in caloric intake.

  19. How to deal with morning bad breath: A randomized, crossover clinical trial.

    PubMed

    Oliveira-Neto, Jeronimo M; Sato, Sandra; Pedrazzi, Vinícius

    2013-11-01

    The absence of a protocol for the treatment of halitosis has led us to compare mouthrinses with mechanical oral hygiene procedures for treating morning breath by employing a hand-held sulfide monitor. To compare the efficacy of five modalities of treatment for controlling morning halitosis in subjects with no dental or periodontal disease. This is a five-period, randomized, crossover clinical trial. Twenty volunteers were randomly assigned to the trial. Testing involved the use of a conventional tongue scraper, a tongue scraper joined to the back of a toothbrush's head, two mouthrinses (0.05% cetylpyridinium chloride and 0.12% chlorhexidine digluconate) and a soft-bristled toothbrush and fluoride toothpaste for practicing oral hygiene. Data analysis was performed using SPSS version 17 for Windows and NCSS 2007 software (P < 0.05). The products and the periods were compared with each other using the Friedman's test. When significant differences (P < 0.05) were determined, the products and periods were compared in pairs by using the Wilcoxon's test and by adjusting the original significance level (0.05) for multiple comparisons by using the Bonferroni's method. The toothbrush's tongue scraper was able to significantly reduce bad breath for up to 2 h. Chlorhexidine reduced bad breath only at the end of the second hour, an effect that lasted for 3 h. Mechanical tongue cleaning was able to immediately reduce bad breath for a short period, whereas chlorhexidine and mechanical oral hygiene reduced bad breath for longer periods, achieving the best results against morning breath.

  20. A Ringdown Breath Analyzer for Diabetes Monitoring: Breath Acetone in Diabetic Patients.

    NASA Astrophysics Data System (ADS)

    Wang, Chuji; Mbi, Armstrong; Shepherd, Mark

    2008-03-01

    It is highly desirable for millions of diabetic patients to have a non-blood, non-invasive, point-of-care device for monitoring daily blood glucose (BG) levels and the adequacy of diabetic treatment and control. Cavity ringdown spectroscopy, due to its unique capability of high sensitivity, fast-response, and relatively low cost for instrumentation, has the potential for medical application through non-invasive analysis of breath biomarkers. We report the first ringdown acetone breath analyzer for clinic testing with diabetic outpatients. The instrument was set in a clinic center and 34 outpatients (24 T1D and 10 T2D) were tested during a four-day period. 10 T1D subjects and 15 nondiabetic persons were tested in our laboratory. Three juvenile-onset T1D subjects were selected for a 24-hr monitoring on the variations of breath acetone and simultaneous BG level. In this talk, we present our research findings including the correlations of breath acetone with BG level and A1C.

  1. FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests

    NASA Astrophysics Data System (ADS)

    Sukul, Pritam; Schubert, Jochen K.; Oertel, Peter; Kamysek, Svend; Taunk, Khushman; Trefz, Phillip; Miekisch, Wolfram

    2016-06-01

    Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange.

  2. FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests

    PubMed Central

    Sukul, Pritam; Schubert, Jochen K.; Oertel, Peter; Kamysek, Svend; Taunk, Khushman; Trefz, Phillip; Miekisch, Wolfram

    2016-01-01

    Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange. PMID:27311826

  3. Random breath testing in Australia: getting it to work according to specifications.

    PubMed

    Homel, R

    1993-01-01

    After reading the deterrence literature, particularly the work of H. Laurence Ross, I concluded in the late 1970's that many road accidents could be prevented through the wholehearted implementation of random breath testing (RBT). RBT is a system of drink-drive law enforcement which aims to increase the perceived likelihood of apprehension through the use of mass breath testing techniques at roadblocks which are highly visible, are unpredictable in their locations and give the impression of ubiquity. As the result of public pressure, RBT was introduced in NSW in December 1982, with spectacular results. The law was intensively enforced and extensively advertised, partly due to the advocacy of researchers such as myself, but also because ther was an acute political need for instant results. Since RBT is a difficult enforcement technique for police to sustain in effective form, researchers must strive to improve their understanding of what works, and remain in close contact with police, policy makers and politicians. Although this process is costly in terms of time and, possibly, academic 'pay-off', it is essential if the fragile understanding of deterrence principles amongst these groups is not to lead to superficially attractive, but probably ineffective techniques such as low visibility mobile RBT.

  4. Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing

    PubMed Central

    2015-01-01

    Background The ability to determine airflow during nasal CPAP (NCPAP) treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing. Methods Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically. Results The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance. Conclusion The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates. PMID:26192188

  5. The effect of radioactive iodine treatment on 14C urea breath test results in patients with hyperthyroidism.

    PubMed

    Arduc, Ayse; Dogan, Bercem Aycicek; Ozuguz, Ufuk; Tuna, Mazhar Muslim; Gokay, Ferhat; Tutuncu, Yasemin Ates; Isik, Serhat; Aydin, Yusuf; Peksoy, Irfan; Berker, Dilek; Guler, Serdar

    2014-12-01

    Radioactive Iodine therapy (RAIT) plays a major role in the treatment of hyperthyroidism. In addition to the thyroid gland, significant amounts of radioactive iodine are maintained in the stomach. The aim of this study was to determine if RAIT has any effect on Helicobacter pylori infection, based on the C urea breath test (UBT). The study included 85 patients with hyperthyroidism scheduled to undergo RAIT and 69 hyperthyroid subjects in whom methimazole treatment was planned. All subjects had pretreatment-positive UBT results, and the test was repeated on the first and third months after RAIT and methimazole treatment. After a mean RAIT dose of 15 mCi (range, 10-20 mCi), UBT became negative in 13 (15.3%) of 85 patients on the first month and 18 (21.2%) of 85 patients on the third month. All subjects treated with methimazole remained UBT positive on the first and third months of methimazole treatment (100%). Reduction in the number of UBT-positive patients on both the first and the third months after RAIT was statistically significant (P < 0.001). Distribution of hyperthyroidism etiologies and thyroid autoantibody levels in subjects with UBT that became negative and in subjects with UBT that remained positive were similar in the RAIT group (P > 0.05). Urea breath test negativity rates did not differ according to the radioiodine dose. Our findings indirectly showed that RAIT might have an antimicrobial effect on H. pylori. Clinical applications of this beneficial effect of RAIT on H. pylori should be further evaluated.

  6. Breath-to-breath hypercapnic response in neonatal rats: temperature dependency of the chemoreflexes and potential implications for breathing stability.

    PubMed

    Cummings, Kevin J; Frappell, Peter B

    2009-07-01

    The breathing of newborns is destabilized by warm temperatures. We hypothesized that in unanesthetized, intact newborn rats, body temperature (T(B)) influences the peripheral chemoreflex response (PCR response) to hypercapnia. To test this, we delivered square-wave challenges of 8% CO(2) in air to postnatal day 4-5 (P4-P5) rats held at a T(B) of 30 degrees C (Cold group, n = 11), 33 degrees C (Cool group, n = 10), and 35 degrees C thermoneutral zone group [thermoneutral zone (TNZ) group, n = 11], while measuring ventilation (Ve) directly with a pneumotach and mask. Cool animals were challenged with 8% CO(2) balanced in either air or hyperoxia (n = 10) to identify the PCR response. Breath-to-breath analysis was performed on 30 room air breaths and every breath of the 1-min CO(2) challenge. As expected, warmer T(B) was associated with an unstable breathing pattern in room air: TNZ animals had a coefficient of variation in Ve (Ve CV%) that was double that of animals held at cooler T(B) (P < 0.001). Hyperoxia markedly suppressed the hypercapnic ventilatory response over the first 10 breaths (or approximately 4 s), suggesting that this domain is dominated by the PCR response. The PCR response (P = 0.03) and total response (P = 0.04) were significantly greater in TNZ animals compared with hypothermic animals. The total response had a significant, negative relationship with Vco(2) (R(2) = 0.53; P < 0.001). Breathing stability was positively related to the total response (R(2) = 0.36; P < 0.001) and to a lesser extent, the PCR response (R(2) = 0.19; P = 0.01) and was negatively related to Vco(2) (R(2) = 0.34; P < 0.001). ANCOVA confirmed a significant effect of T(B) alone on breathing stability (P < 0.01), with no independent effects of Vco(2) (P = 0.41), the PCR response (P = 0.82), or the total Ve response (P = 0.08). Our data suggest that in early postnatal life, the chemoreflex responses to CO(2) are highly influenced by T(B), and while related to breathing stability

  7. Hypercarbic cardiorespiratory reflexes in the facultative air-breathing fish jeju (Hoplerythrinus unitaeniatus): the role of branchial CO2 chemoreceptors.

    PubMed

    de Lima Boijink, Cheila; Florindo, Luiz Henrique; Leite, Cleo A Costa; Kalinin, Ana Lúcia; Milsom, William K; Rantin, Francisco Tadeu

    2010-08-15

    The aim of the present study was to determine the roles that externally versus internally oriented CO(2)/H(+)-sensitive chemoreceptors might play in promoting cardiorespiratory responses to environmental hypercarbia in the air-breathing fish, Hoplerythrinus unitaeniatus (jeju). Fish were exposed to graded hypercarbia (1, 2.5, 5, 10 and 20% CO(2)) and also to graded levels of environmental acidosis (pH approximately 7.0, 6.0, 5.8, 5.6, 5.3 and 4.7) equal to the pH levels of the hypercarbic water to distinguish the relative roles of CO(2) versus H(+). We also injected boluses of CO(2)-equilibrated solutions (5, 10 and 20% CO(2)) and acid solutions equilibrated to the same pH as the CO(2) boluses into the caudal vein (internal) and buccal cavity (external) to distinguish between internal and external stimuli. The putative location of the chemoreceptors was determined by bilateral denervation of branches of cranial nerves IX (glossopharyngeal) and X (vagus) to the gills. The data indicate that the chemoreceptors eliciting bradycardia, hypertension and gill ventilatory responses (increased frequency and amplitude) to hypercarbia are exclusively branchial, externally oriented and respond specifically to changes in CO(2) and not H(+). Those involved in producing the cardiovascular responses appeared to be distributed across all gill arches while those involved in the gill ventilatory responses were located primarily on the first gill arch. Higher levels of aquatic CO(2) depressed gill ventilation and stimulated air breathing. The chemoreceptors involved in producing air breathing in response to hypercarbia also appeared to be branchial, distributed across all gill arches and responded specifically to changes in aquatic CO(2). This would suggest that chemoreceptor groups with different orientations (blood versus water) are involved in eliciting air-breathing responses to hypercarbia in jeju.

  8. Breath acidification in adolescent runners exposed to atmospheric pollution: A prospective, repeated measures observational study

    PubMed Central

    Ferdinands, Jill M; Crawford, Carol A Gotway; Greenwald, Roby; Van Sickle, David; Hunter, Eric; Teague, W Gerald

    2008-01-01

    Background Vigorous outdoors exercise during an episode of air pollution might cause airway inflammation. The purpose of this study was to examine the effects of vigorous outdoor exercise during peak smog season on breath pH, a biomarker of airway inflammation, in adolescent athletes. Methods We measured breath pH both pre- and post-exercise on ten days during peak smog season in 16 high school athletes engaged in daily long-distance running in a downwind suburb of Atlanta. The association of post-exercise breath pH with ambient ozone and particulate matter concentrations was tested with linear regression. Results We collected 144 pre-exercise and 146 post-exercise breath samples from 16 runners (mean age 14.9 years, 56% male). Median pre-exercise breath pH was 7.58 (interquartile range: 6.90 to 7.86) and did not change significantly after exercise. We observed no significant association between ambient ozone or particulate matter and post-exercise breath pH. However both pre- and post-exercise breath pH were strikingly low in these athletes when compared to a control sample of 14 relatively sedentary healthy adults and to published values of breath pH in healthy subjects. Conclusion Although we did not observe an acute effect of air pollution exposure during exercise on breath pH, breath pH was surprisingly low in this sample of otherwise healthy long-distance runners. We speculate that repetitive vigorous exercise may induce airway acidification. PMID:18328105

  9. Developmental cardiorespiratory physiology of the air-breathing tropical gar, Atractosteus tropicus.

    PubMed

    Burggren, Warren W; Bautista, Gil Martinez; Coop, Susana Camarillo; Couturier, Gabriel Márquez; Delgadillo, Salomón Páramo; García, Rafael Martínez; González, Carlos Alfonso Alvarez

    2016-10-01

    The physiological transition to aerial breathing in larval air-breathing fishes is poorly understood. We investigated gill ventilation frequency (f G ), heart rate (f H ), and air breathing frequency (f AB ) as a function of development, activity, hypoxia, and temperature in embryos/larvae from day (D) 2.5 to D30 posthatch of the tropical gar, Atractosteus tropicus, an obligate air breather. Gill ventilation at 28°C began at approximately D2, peaking at ∼75 beats/min on D5, before declining to ∼55 beats/min at D30. Heart beat began ∼36-48 h postfertilization and ∼1 day before hatching. f H peaked between D3 and D10 at ∼140 beats/min, remaining at this level through D30. Air breathing started very early at D2.5 to D3.5 at 1-2 breaths/h, increasing to ∼30 breaths/h at D15 and D30. Forced activity at all stages resulted in a rapid but brief increase in both f G and f H , (but not f AB ), indicating that even in these early larval stages, reflex control existed over both ventilation and circulation prior to its increasing importance in older fishes. Acute progressive hypoxia increased f G in D2.5-D10 larvae, but decreased f G in older larvae (≥D15), possibly to prevent branchial O 2 loss into surrounding water. Temperature sensitivity of f G and f H measured at 20°C, 25°C, 28°C and 38°C was largely independent of development, with a Q 10 between 20°C and 38°C of ∼2.4 and ∼1.5 for f G and f H , respectively. The rapid onset of air breathing, coupled with both respiratory and cardiovascular reflexes as early as D2.5, indicates that larval A. tropicus develops "in the fast lane." Copyright © 2016 the American Physiological Society.

  10. (13)C breath tests in personalized medicine: fiction or reality?

    PubMed

    Modak, Anil S

    2009-11-01

    The concept of personalized medicine is gathering momentum as various biomarkers are being discovered and developed to lead to genotype and phenotype diagnostic tests, which will enable physicians to individualize therapy. Noninvasive, rapid (13)C breath tests have the potential to serve as clinically significant diagnostic tools, especially for evaluating the enzyme activity of polymorphic enzymes. This would enable physicians to rapidly identify responders/nonresponders to various drugs primarily metabolized by these enzymes prior to initiation of therapy. With the information on enzyme activity, the physician can prescribe the right drug, at the right dose, at the right time, to the right individual, for the right clinical outcome. However, the promise of the era of personalized medicine, including the novel (13)C breath tests, will have to overcome several regulatory, business and financial hurdles for diagnostic tests to become part of routine mainstream clinical practice over the next decade.

  11. The effect of CO2 on ventilation and breath-holding during exercise and while breathing through an added resistance.

    PubMed

    Clark, T J; Godfrey, S

    1969-05-01

    1. Ventilation was measured while subjects were made to rebreathe from a bag containing CO(2) and O(2) in order to expose them to a steadily rising CO(2) tension (P(CO2)). The object of the experiments was to determine the effect of a variety of stimuli upon the increase in ventilation and fall in breath-holding time which occurs in response to the rising P(CO2).2. Steady-state exercise at 200 kg.m/min resulted in a small fall in the slope of the ventilation-CO(2) response curve (S(V)) and a small, though not statistically significant, fall in the P(CO2) at which ventilation would be zero by extrapolation (B(V)). There was a marked fall in the slope of the breath-holding-CO(2) response curve (S(BH)) and an increase in the P(CO2) at which breath-holding time became zero by extrapolation (B(BH)).3. These results have been interpreted with the aid of a model of the control of breath-holding and it is suggested that there is no change in CO(2) sensitivity on exercise, either during rebreathing or breath-holding.4. An increase in the resistance to breathing caused a marked reduction in S(V) and B(V), but no change in the breath-holding-CO(2) response curve. These findings suggest that the flattening of the ventilation-CO(2) response curve is mechanical in origin and acute airway obstruction produces no change in CO(2) sensitivity.5. On the basis of these results, we suggest that more information about CO(2) sensitivity can be obtained by a combination of ventilation and breath-holding-CO(2) response curves.

  12. How to deal with morning bad breath: A randomized, crossover clinical trial

    PubMed Central

    Oliveira-Neto, Jeronimo M.; Sato, Sandra; Pedrazzi, Vinícius

    2013-01-01

    Context: The absence of a protocol for the treatment of halitosis has led us to compare mouthrinses with mechanical oral hygiene procedures for treating morning breath by employing a hand-held sulfide monitor. Aims: To compare the efficacy of five modalities of treatment for controlling morning halitosis in subjects with no dental or periodontal disease. Settings and Design: This is a five-period, randomized, crossover clinical trial. Materials and Methods: Twenty volunteers were randomly assigned to the trial. Testing involved the use of a conventional tongue scraper, a tongue scraper joined to the back of a toothbrush's head, two mouthrinses (0.05% cetylpyridinium chloride and 0.12% chlorhexidine digluconate) and a soft-bristled toothbrush and fluoride toothpaste for practicing oral hygiene. Statistical Analysis Used: Data analysis was performed using SPSS version 17 for Windows and NCSS 2007 software (P < 0.05). The products and the periods were compared with each other using the Friedman's test. When significant differences (P < 0.05) were determined, the products and periods were compared in pairs by using the Wilcoxon's test and by adjusting the original significance level (0.05) for multiple comparisons by using the Bonferroni's method. Results: The toothbrush's tongue scraper was able to significantly reduce bad breath for up to 2 h. Chlorhexidine reduced bad breath only at the end of the second hour, an effect that lasted for 3 h. Conclusions: Mechanical tongue cleaning was able to immediately reduce bad breath for a short period, whereas chlorhexidine and mechanical oral hygiene reduced bad breath for longer periods, achieving the best results against morning breath. PMID:24554886

  13. Autonomic control of post-air-breathing tachycardia in Clarias gariepinus (Teleostei: Clariidae).

    PubMed

    Teixeira, Mariana Teodoro; Armelin, Vinicius Araújo; Abe, Augusto Shinya; Rantin, Francisco Tadeu; Florindo, Luiz Henrique

    2015-08-01

    The African catfish (Clarias gariepinus) is a teleost with bimodal respiration that utilizes a paired suprabranchial chamber located in the gill cavity as an air-breathing organ. Like all air-breathing fishes studied to date, the African catfish exhibits pronounced changes in heart rate (f H) that are associated with air-breathing events. We acquired f H, gill-breathing frequency (f G) and air-breathing frequency (f AB) in situations that require or do not require air breathing (during normoxia and hypoxia), and we assessed the autonomic control of post-air-breathing tachycardia using an infusion of the β-adrenergic antagonist propranolol and the muscarinic cholinergic antagonist atropine. During normoxia, C. gariepinus presented low f AB (1.85 ± 0.73 AB h(-1)) and a constant f G (43.16 ± 1.74 breaths min(-1)). During non-critical hypoxia (PO2 = 60 mmHg), f AB in the African catfish increased to 5.42 ± 1.19 AB h(-1) and f G decreased to 39.12 ± 1.58 breaths min(-1). During critical hypoxia (PO2 = 20 mmHg), f AB increased to 7.4 ± 1.39 AB h(-1) and f G decreased to 34.97 ± 1.78 breaths min(-1). These results were expected for a facultative air breather. Each air breath (AB) was followed by a brief but significant tachycardia, which in the critical hypoxia trials, reached a maximum of 143 % of the pre-AB f H values of untreated animals. Pharmacological blockade allowed the calculation of cardiac autonomic tones, which showed that post-AB tachycardia is predominantly regulated by the parasympathetic subdivision of the autonomic nervous system.

  14. 13CO2/12CO2 isotope ratio analysis in human breath using a 2 μm diode laser

    NASA Astrophysics Data System (ADS)

    Sun, Mingguo; Cao, Zhensong; Liu, Kun; Wang, Guishi; Tan, Tu; Gao, Xiaoming; Chen, Weidong; Yinbo, Huang; Ruizhong, Rao

    2015-04-01

    The bacterium H. pylori is believed to cause peptic ulcer. H. pylori infection in the human stomach can be diagnosed through a CO2 isotope ratio measure in exhaled breath. A laser spectrometer based on a distributed-feedback semiconductor diode laser at 2 μm is developed to measure the changes of 13CO2/12CO2 isotope ratio in exhaled breath sample with the CO2 concentration of ~4%. It is characterized by a simplified optical layout, in which a single detector and associated electronics are used to probe CO2 spectrum. A new type multi-passes cell with 12 cm long base length , 29 m optical path length in total and 280 cm3 volume is used in this work. The temperature and pressure are well controlled at 301.15 K and 6.66 kPa with fluctuation amplitude of 25 mK and 6.7 Pa, respectively. The best 13δ precision of 0.06o was achieved by using wavelet denoising and Kalman filter. The application of denoising and Kalman filter not only improved the signal to noise ratio, but also shorten the system response time.

  15. Evaluation of the 13C-octanoate breath test as a surrogate marker of liver damage in animal models.

    PubMed

    Shalev, Tamar; Aeed, Hussein; Sorin, Vladimir; Shahmurov, Mark; Didkovsky, Elena; Ilan, Yaron; Avni, Yona; Shirin, Haim

    2010-06-01

    Octanoate (also known as sodium octanoate), a medium-chain fatty acid metabolized in the liver, is a potential substrate for non-invasive breath testing of hepatic mitochondrial beta-oxidation. We evaluated the 13C-octanoate breath test (OBT) for assessing injury in acute hepatitis and two rat models of liver cirrhosis, first testing octanoate absorption (per os or intraperitoneally (i.p.)) in normal rats. We then induced acute hepatitis with thioacetamide (300 mg/kg/i.p., 24-h intervals). Liver injury end points were serum aminotransferase levels and 13C-OBT (24 and 48 h following initial injection). Thioacetamide (200 mg/kg/i.p., twice per week, 12 weeks) was used to induce liver cirrhosis. OBT and liver histological assessment were performed every 4 weeks. Bile duct ligation (BDL) was used to induce cholestatic liver injury. We completed breath tests with 13C-OBT and 13C-methacetin (MBID), liver biochemistry, and liver histology in BDL and sham-operated rats (baseline, 6, 14, 20 days post-BDL). Octanoate absorbs well by either route. Peak amplitudes and cumulative percentage dose recovered at 30 and 60 min (CPDR30/60), but not peak time, correlated with acute hepatitis. Fibrosis stage 3 at week 8 significantly correlated with each OBT parameter. Cholestatic liver injury (serum bilirubin, ALP, gamma-GT, liver histology) was associated with significant suppression of the maximal peak values and CPDR30/60, respectively (P<0.05),using MBID but not 13C-octanoate. OBT is sensitive for potentially evaluating liver function in rat models of acute hepatitis and thioacetamide-induced liver cirrhosis but not in cholestatic liver injury. The MBID test may be better for evaluation of cholestatic liver disease in this model.

  16. Comparison between hyperventilation and breath-holding in panic disorder: patients responsive and non-responsive to both tests.

    PubMed

    Nardi, Antonio E; Valença, Alexandre M; Mezzasalma, Marco A; Levy, Sandra P; Lopes, Fabiana L; Nascimento, Isabella; Freire, Rafael C; Veras, Andre B; Zin, Walter A

    2006-06-15

    Our aim was to compare the demographic and psychopathological features of panic disorder (PD) patients who underwent hyperventilation and breath-holding challenge tests, and to describe the features of patients who had a panic attack after both tests versus those patients who did not experience panic after either test. Eighty-five PD patients were induced to hyperventilate (30 breaths/min) for 4 min, and a week later to hold their breath for as long as possible four times with a 2-min interval in between. Anxiety scales were applied before and after the tests. Patients who responded with a panic attack to both tests (BPA, n = 25) were compared with patients who experienced spontaneous panic attacks but did not panic in response to the two tests (NPA, n = 16). The BPA group had a significantly higher presence of respiratory symptoms during a panic attack. The criteria for the respiratory PD subtype were fulfilled in 18 (72.0%) BPA patients and in 6 (37.5%) NPA patients. The BPA patients had a later onset of panic disorder and a higher familial prevalence of PD. Our data suggest that there is a distinction between PD patients who were sensitive to both hyperventilation and breath-holding tests and PD patients who were not affected by the challenge tests. The panic attack may be a final common pathway for different types of stimuli, and respiratory tests may characterize different PD subgroups.

  17. Flavoring agents present in a dentifrice can modify volatile sulphur compounds (VSCs) formation in morning bad breath.

    PubMed

    Peruzzo, Daiane Cristina; Salvador, Sérgio Luis; Sallum, Antonio Wilson; Nogueira-Filho, Getúlio da Rocha

    2008-01-01

    This study aimed to evaluate the effects of a flavor-containing dentifrice on the formation of volatile sulphur compounds (VSCs) in morning bad breath. A two-step, blinded, crossover, randomized study was carried out in 50 dental students with a healthy periodontium divided into two experimental groups: flavor-containing dentifrice (test) and non-flavor-containing dentifrice (control). The volunteers received the designated dentifrice and a new toothbrush for a 3 X/day brushing regimen for 2 periods of 30 days. A seven-day washout interval was used between the periods. The assessed parameters were: plaque index (PI), gingival index (GI), organoleptic breath scores (ORG), VSC levels (as measured by a portable sulphide monitor) before (H1) and after (H2) cleaning of the tongue, tongue coating (TC) wet weight and BANA test from TC samples. The intra-group analysis showed a decrease in ORG, from 3 to 2, after 30 days for the test group (p < 0.05). The inter-group analysis showed lower values in ORG, H1 and H2 for the test group (p < 0.05). There was no difference between the amount of TC between groups and the presence of flavor also did not interfere in the BANA results between groups (p > 0.05). These findings suggest that a flavor-containing dentifrice seems to prevent VSCs formation in morning bad breath regardless of the amount of TC in periodontally healthy subjects.

  18. Quantification of Helicobacter pylori infection in gastritis and ulcer disease using a simple and rapid carbon-14-urea breath test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Debongnie, J.C.; Pauwels, S.; Raat, A.

    1991-06-01

    Gastric urease was studied isotopically in 230 patients with biopsy-proven normal mucosa or chronic gastritis, including 59 patients with ulcer disease. Carbon-14-urea was given in 25 ml of water without substrate carrier or nutrient-dense meal, and breath samples were collected over a 60-min period. The amount of 14CO2 excreted at 10 min was independent of the rate of gastric emptying and was not quantitatively influenced by the buccal urease activity. The 10-min 14CO2 values discriminated well between Helicobacter pylori positive and negative patients (94% sensitivity, 89% specificity) and correlated with the number of organisms assessed by histology. The test wasmore » a good predictor of chronic gastritis (95% sensitivity and 96% specificity), and a quantitative relationship was observed between 14CO2 values and the severity and activity of the gastritis. In H. pylori positive patients, breath 14CO2 was found to be similar in patients with and without ulcer disease, suggesting that the number of bacteria is not a determining factor for the onset of ulceration.« less

  19. Breath Test Refusals and Their Effect on DWI Prosecution

    DOT National Transportation Integrated Search

    2012-07-01

    This report describes the design and results of a project aimed at estimating the rate that drivers : refuse to submit to a legally-requested breath alcohol concentration test, and the effect of such : refusals on the prosecution of DWI cases. The st...

  20. Updating prognosis of cirrhosis by Cox's regression model using Child-Pugh score and aminopyrine breath test as time-dependent covariates.

    PubMed

    Merkel, C; Morabito, A; Sacerdoti, D; Bolognesi, M; Angeli, P; Gatta, A

    1998-06-01

    The determination of aminopyrine breath test on entry into the study was recently shown to improve the accuracy of prediction of death based on the Child-Pugh classification, but the possible usefulness of serial determinations of both parameters has not been assessed. In the present study, we aimed at evaluating whether serial determinations of aminopyrine breath test and Child-Pugh score improve prognostic accuracy in patients with cirrhosis, compared with determinations obtained only on admission. In 74 patients with liver cirrhosis aminopyrine breath test and Child-Pugh score were obtained upon entry into the study. Patients were followed with sequential aminopyrine breath tests and assessments of the Child-Pugh score every 4-6 months. A total number of 232 determinations were obtained. During follow-up 45 patients died, on average after 12 months of follow-up. Child-Pugh score improved in the beginning of follow-up, and then remained fairly constant; aminopyrine breath test showed no improvement in the beginning of follow-up, but rather a slowly progressive decline. In patients who died, both the Child-Pugh score and the metabolism of aminopyrine were significantly more impaired in the last year preceding death (p < 0.05). Applying Cox's regression model with time-dependent covariates, Child-Pugh score and aminopyrine breath test were independent significant predictors of survival. The model with time-dependent covariates explained the observed survival much better than the model with time-fixed covariates (chi-sq. explained by regression = 31.45 vs 11.97; d.f. = 2; p = 0.0000001 vs 0.003). These data suggest that serial determinations of Child-Pugh score and aminopyrine breath test can be used to efficiently update prognosis of cirrhosis.

  1. A better state-of-mind: deep breathing reduces state anxiety and enhances test performance through regulating test cognitions in children.

    PubMed

    Khng, Kiat Hui

    2017-11-01

    A pre-test/post-test, intervention-versus-control experimental design was used to examine the effects, mechanisms and moderators of deep breathing on state anxiety and test performance in 122 Primary 5 students. Taking deep breaths before a timed math test significantly reduced self-reported feelings of anxiety and improved test performance. There was a statistical trend towards greater effectiveness in reducing state anxiety for boys compared to girls, and in enhancing test performance for students with higher autonomic reactivity in test-like situations. The latter moderation was significant when comparing high-versus-low autonomic reactivity groups. Mediation analyses suggest that deep breathing reduces state anxiety in test-like situations, creating a better state-of-mind by enhancing the regulation of adaptive-maladaptive thoughts during the test, allowing for better performance. The quick and simple technique can be easily learnt and effectively applied by most children to immediately alleviate some of the adverse effects of test anxiety on psychological well-being and academic performance.

  2. Breathing metabolic simulator

    NASA Technical Reports Server (NTRS)

    Bartlett, R. G.; Hendricks, C. M.; Morison, W. B.

    1972-01-01

    The development of a breathing metabolic simulator (BMS) is reported. This BMS simulates all of the breathing and metabolic parameters required for complete evaluation and test of life support and resuscitation equipment. It is also useful for calibrating and validating mechanical and gaseous pulmonary function test procedures. Breathing rate, breathing depth, breath velocity contour, oxygen uptake, and carbon dioxide release are all variable over wide ranges simulating conditions from sleep to hard work with respiratory exchange ratios covering the range from hypoventilation. In addition, all of these parameters are remotely controllable to facilitate use of the device in hostile or remote environments. The exhaled breath is also maintained at body temperature and a high humidity. The simulation is accurate to the extent of having a variable functional residual capacity independent of other parameters.

  3. Rapid Point-Of-Care Breath Test for Biomarkers of Breast Cancer and Abnormal Mammograms

    PubMed Central

    Phillips, Michael; Beatty, J. David; Cataneo, Renee N.; Huston, Jan; Kaplan, Peter D.; Lalisang, Roy I.; Lambin, Philippe; Lobbes, Marc B. I.; Mundada, Mayur; Pappas, Nadine; Patel, Urvish

    2014-01-01

    Background Previous studies have reported volatile organic compounds (VOCs) in breath as biomarkers of breast cancer and abnormal mammograms, apparently resulting from increased oxidative stress and cytochrome p450 induction. We evaluated a six-minute point-of-care breath test for VOC biomarkers in women screened for breast cancer at centers in the USA and the Netherlands. Methods 244 women had a screening mammogram (93/37 normal/abnormal) or a breast biopsy (cancer/no cancer 35/79). A mobile point-of-care system collected and concentrated breath and air VOCs for analysis with gas chromatography and surface acoustic wave detection. Chromatograms were segmented into a time series of alveolar gradients (breath minus room air). Segmental alveolar gradients were ranked as candidate biomarkers by C-statistic value (area under curve [AUC] of receiver operating characteristic [ROC] curve). Multivariate predictive algorithms were constructed employing significant biomarkers identified with multiple Monte Carlo simulations and cross validated with a leave-one-out (LOO) procedure. Results Performance of breath biomarker algorithms was determined in three groups: breast cancer on biopsy versus normal screening mammograms (81.8% sensitivity, 70.0% specificity, accuracy 79% (73% on LOO) [C-statistic value], negative predictive value 99.9%); normal versus abnormal screening mammograms (86.5% sensitivity, 66.7% specificity, accuracy 83%, 62% on LOO); and cancer versus no cancer on breast biopsy (75.8% sensitivity, 74.0% specificity, accuracy 78%, 67% on LOO). Conclusions A pilot study of a six-minute point-of-care breath test for volatile biomarkers accurately identified women with breast cancer and with abnormal mammograms. Breath testing could potentially reduce the number of needless mammograms without loss of diagnostic sensitivity. PMID:24599224

  4. Synthesis of ¹³C-lidocaine as a probe of breath test for the evaluation of cytochrome P450 activity.

    PubMed

    Mitome, Hidemichi; Sugiyama, Erika; Sato, Hitoshi; Akira, Kazuki

    2014-01-01

    (13)C-Labeled lidocaine, 2-di[1-(13)C]ethylamino-N-(2,6-dimethylphenyl)acetamide (1), was synthesized from [1-(13)C]acetic acid in six steps, as a probe for a breath test to evaluate in vivo cytochrome P450 activity. The measurement of (13)CO2 in breath was successfully performed following oral administration of (13)C-lidocaine 1 to mice.

  5. Update on diagnostic value of breath test in gastrointestinal and liver diseases

    PubMed Central

    Siddiqui, Imran; Ahmed, Sibtain; Abid, Shahab

    2016-01-01

    In the field of gastroenterology, breath tests (BTs) are used intermittently as diagnostic tools that allow indirect, non-invasive and relatively less cumbersome evaluation of several disorders by simply quantifying the appearance in exhaled breath of a metabolite of a specific substrate administered. The aim of this review is to have an insight into the principles, methods of analysis and performance parameters of various hydrogen, methane and carbon BTs which are available for diagnosing gastrointestinal disorders such as Helicobacter pylori infection, small intestinal bacterial overgrowth, and carbohydrate malabsorption. Evaluation of gastric emptying is routinely performed by scintigraphy which is however, difficult to perform and not suitable for children and pregnant women, this review has abridged the 13C-octanoic acid test in comparison to scintigraphy and has emphasized on its working protocol and challenges. A new development such as electronic nose test is also highlighted. Moreover we have also explored the limitations and constraints restraining the wide use of these BT. We conclude that breath testing has an enormous potential to be used as a diagnostic modality. In addition it offers distinct advantages over the traditional invasive methods commonly employed. PMID:27574563

  6. Mechanisms linking metabolism of Helicobacter pylori to 18O and 13C-isotopes of human breath CO2

    PubMed Central

    Som, Suman; De, Anulekha; Banik, Gourab Dutta; Maity, Abhijit; Ghosh, Chiranjit; Pal, Mithun; Daschakraborty, Sunil B.; Chaudhuri, Sujit; Jana, Subhra; Pradhan, Manik

    2015-01-01

    The gastric pathogen Helicobacter pylori utilize glucose during metabolism, but the underlying mechanisms linking to oxygen-18 (18O) and carbon-13 (13C)-isotopic fractionations of breath CO2 during glucose metabolism are poorly understood. Using the excretion dynamics of 18O/16O and 13C/12C-isotope ratios of breath CO2, we found that individuals with Helicobacter pylori infections exhibited significantly higher isotopic enrichments of 18O in breath CO2 during the 2h-glucose metabolism regardless of the isotopic nature of the substrate, while no significant enrichments of 18O in breath CO2 were manifested in individuals without the infections. In contrast, the 13C-isotopic enrichments of breath CO2 were significantly higher in individuals with Helicobacter pylori compared to individuals without infections in response to 13C-enriched glucose uptake, whereas a distinguishable change of breath 13C/12C-isotope ratios was also evident when Helicobacter pylori utilize natural glucose. Moreover, monitoring the 18O and 13C-isotopic exchange in breath CO2 successfully diagnosed the eradications of Helicobacter pylori infections following a standard therapy. Our findings suggest that breath 12C18O16O and 13C16O16O can be used as potential molecular biomarkers to distinctively track the pathogenesis of Helicobacter pylori and also for eradication purposes and thus may open new perspectives into the pathogen’s physiology along with isotope-specific non-invasive diagnosis of the infection. PMID:26039789

  7. Effect of exhaled moisture on breathing resistance of N95 filtering facepiece respirators.

    PubMed

    Roberge, Raymond J; Bayer, Emily; Powell, Jeffrey B; Coca, Aitor; Roberge, Marc R; Benson, Stacey M

    2010-08-01

    This study evaluated the effect of exhaled moisture on the breathing resistance of three classes of filtering facepiece respirators (FFR) following 4 h of continuous wear at a breathing volume of 40 l min(-1), utilizing an automated breathing and metabolic simulator as a human surrogate. After 4 h, inhalation and exhalation resistance increased by 0.43 and 0.23 mm of H(2)O pressure, respectively, and average moisture retention in the respirators was 0.26 ml. Under ambient conditions similar to those of the current study, and at similar breathing volumes, it is unlikely that exhaled moisture will add significantly to the breathing resistance of filtering facepiece respirators (FFR) over 4 h of use.

  8. The effect of breathing an ambient low‐density, hyperoxic gas on the perceived effort of breathing and maximal performance of exercise in well‐trained athletes

    PubMed Central

    Ansley, L; Petersen, D; Thomas, A; Gibson, A St Clair; Robson‐Ansley, P; Noakes, T D

    2007-01-01

    Background The role of the perception of breathing effort in the regulation of performance of maximal exercise remains unclear. Aims To determine whether the perceived effort of ventilation is altered through substituting a less dense gas for normal ambient air and whether this substitution affects performance of maximal incremental exercise in trained athletes. Methods Eight highly trained cyclists (mean SD) maximal oxygen consumption (VO2max) = 69.9 (7.9) (mlO2/kg/min) performed two randomised maximal tests in a hyperbaric chamber breathing ambient air composed of either 35% O2/65% N2 (nitrox) or 35% O2/65% He (heliox). A ramp protocol was used in which power output was incremented at 0.5 W/s. The trials were separated by at least 48 h. The perceived effort of breathing was obtained via Borg Category Ratio Scales at 3‐min intervals and at fatigue. Oxygen consumption (VO2) and minute ventilation (VE) were monitored continuously. Results Breathing heliox did not change the sensation of dyspnoea: there were no differences between trials for the Borg scales at any time point. Exercise performance was not different between the nitrox and heliox trials (peak power output = 451 (58) and 453 (56) W), nor was VO2max (4.96 (0.61) and 4.88 (0.65) l/min) or maximal VE (157 (24) and 163 (22) l/min). Between‐trial variability in peak power output was less than either VO2max or maximal VE. Conclusion Breathing a less dense gas does not improve maximal performance of exercise or reduce the perception of breathing effort in highly trained athletes, although an attenuated submaximal tidal volume and VE with a concomitant reduction in VO2 suggests an improved gas exchange and reduced O2 cost of ventilation when breathing heliox. PMID:17062658

  9. [13C]Glucose Breath Testing Provides a Noninvasive Measure of Insulin Resistance: Calibration Analyses Against Clamp Studies

    PubMed Central

    Hussain, Maysa; Jangorbhani, Morteza; Schuette, Sally; Considine, Robert V.; Chisholm, Robin L.

    2014-01-01

    Abstract Background: Exhaled 13CO2 following ingestion of [13C]glucose with a standard oral glucose tolerance load correlates with blood glucose values but is determined by tissue glucose uptake. Therefore exhaled 13CO2 may also be a surrogate measure of the whole-body glucose disposal rate (GDR) measured by the gold standard hyperinsulinemic euglycemic clamp. Subjects and Methods: Subjects from across the glycemia range were studied on 2 consecutive days under fasting conditions. On Day 1, a 75-g oral glucose load spiked with [13C]glucose was administered. On Day 2, a hyperinsulinemic euglycemic clamp was performed. Correlations between breath parameters and clamp-derived GDR were evaluated, and calibration analyses were performed to evaluate the precision of breath parameter predictions of clamp measures. Results: Correlations of breath parameters with GDR and GDR per kilogram of fat-free mass (GDRffm) ranged from 0.54 to 0.61 and 0.54 to 0.66, respectively (all P<0.001). In calibration analyses the root mean square error for breath parameters predicting GDR and GDRffm ranged from 2.32 to 2.46 and from 3.23 to 3.51, respectively. Cross-validation prediction error (CVPE) estimates were 2.35–2.51 (GDR) and 3.29–3.57 (GDRffm). Prediction precision of breath enrichment at 180 min predicting GDR (CVPE=2.35) was superior to that for inverse insulin (2.68) and the Matsuda Index (2.51) but inferior to that for the log of homeostasis model assessment (2.21) and Quantitative Insulin Sensitivity Check Index (2.29) (all P<10−5). Similar patterns were seen for predictions of GDRffm. Conclusions: 13CO2 appearance in exhaled breath following a standard oral glucose load with added [13C]glucose provides a valid surrogate index of clamp-derived measures of whole-body insulin resistance, with good accuracy and precision. This noninvasive breath test-based approach can provide a useful measure of whole-body insulin resistance in physiologic and epidemiologic studies. PMID

  10. Comparison of the metabolic and ventilatory response to hypoxia and H2S in unsedated mice and rats.

    PubMed

    Haouzi, Philippe; Bell, Harold J; Notet, Veronique; Bihain, Bernard

    2009-07-31

    Hypoxia alters the control of breathing and metabolism by increasing ventilation through the arterial chemoreflex, an effect which, in small-sized animals, is offset by a centrally mediated reduction in metabolism and respiration. We tested the hypothesis that hydrogen sulfide (H(2)S) is involved in transducing these effects in mammals. The rationale for this hypothesis is twofold. Firstly, inhalation of a 20-80 ppm H(2)S reduces metabolism in small mammals and this effect is analogous to that of hypoxia. Secondly, endogenous H(2)S appears to mediate some of the cardio-vascular effects of hypoxia in non-mammalian species. We, therefore, compared the ventilatory and metabolic effects of exposure to 60 ppm H(2)S and to 10% O(2) in small and large rodents (20g mice and 700g rats) wherein the metabolic response to hypoxia has been shown to differ according to body mass. H(2)S and hypoxia produced profound depression in metabolic rate in the mice, but not in the large rats. The depression was much faster with H(2)S than with hypoxia. The relative hyperventilation produced by hypoxia in the mice was replaced by a depression with H(2)S, which paralleled the drop in metabolic rate. In the larger rats, ventilation was stimulated in hypoxia, with no change in metabolism, while H(2)S affected neither breathing nor metabolism. When mice were simultaneously exposed to H(2)S and hypoxia, the stimulatory effects of hypoxia on breathing were abolished, and a much larger respiratory and metabolic depression was observed than with H(2)S alone. H(2)S had, therefore, no stimulatory effect on the arterial chemoreflex. The ventilatory depression during hypoxia and H(2)S in small mammals appears to be dependent upon the ability to decrease metabolism.

  11. Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements.

    PubMed

    Wang, Zhennan; Wang, Chuji

    2013-09-01

    Since the ancient discovery of the 'sweet odor' in human breath gas, pursuits of the breath analysis-based disease diagnostics have never stopped. Actually, the 'smell' of the breath, as one of three key disease diagnostic techniques, has been used in Eastern-Medicine for more than three thousand years. With advancement of measuring technologies in sensitivity and selectivity, more specific breath gas species have been identified and established as a biomarker of a particular disease. Acetone is one of the breath gases and its concentration in exhaled breath can now be determined with high accuracy using various techniques and methods. With the worldwide prevalence of diabetes that is typically diagnosed through blood testing, human desire to achieve non-blood based diabetic diagnostics and monitoring has never been quenched. Questions, such as is breath acetone a biomarker of diabetes and how is the breath acetone related to the blood glucose (BG) level (the golden criterion currently used in clinic for diabetes diagnostic, monitoring, and management), remain to be answered. A majority of current research efforts in breath acetone measurements and its technology developments focus on addressing the first question. The effort to tackle the second question has begun recently. The earliest breath acetone measurement in clearly defined diabetic patients was reported more than 60 years ago. For more than a half-century, as reviewed in this paper, there have been more than 41 independent studies of breath acetone using various techniques and methods, and more than 3211 human subjects, including 1581 healthy people, 242 Type 1 diabetic patients, 384 Type 2 diabetic patients, 174 unspecified diabetic patients, and 830 non-diabetic patients or healthy subjects who are under various physiological conditions, have been used in the studies. The results of the breath acetone measurements collected in this review support that many conditions might cause changes to breath

  12. Molecular hydrogen in human breath: a new strategy for selectively diagnosing peptic ulcer disease, non-ulcerous dyspepsia and Helicobacter pylori infection.

    PubMed

    Maity, Abhijit; Pal, Mithun; Maithani, Sanchi; Ghosh, Barnali; Chaudhuri, Sujit; Pradhan, Manik

    2016-07-22

    The gastric pathogen Helicobacter pylori utilizes molecular hydrogen (H2) as a respiratory substrate during colonization in the gastric mucosa. However, the link between molecular H2 and the pathogenesis of peptic-ulcer disease (PUD) and non-ulcerous dyspepsia (NUD) by the enzymatic activity of H. pylori still remains mostly unknown. Here we provide evidence that breath H2 excretion profiles are distinctly altered by the enzymatic activity of H. pylori for individuals with NUD and PUD. We subsequently unravelled the potential molecular mechanisms responsible for the alteration of H2 in exhaled breath in association with peptic ulcers, encompassing both gastric and duodenal ulcers, along with NUD. We also established that carbon-isotopic fractionations in the acid-mediated bacterial environment regulated by bacterial urease activity cannot discriminate the actual disease state i.e. whether it is peptic ulcer or NUD. However, our findings illuminate the unusual molecular H2 in breath that can track the precise evolution of PUD and NUD, even after the eradication of H. pylori infection. This deepens our understanding of the pathophysiology of PUD and NUD, reveals non-invasively the actual disease state in real-time and thus offers a novel and robust new-generation strategy for treating peptic-ulcer disease together with non-ulcer related complications even when the existing (13)C-urea breath test ((13)C-UBT) fails to diagnose.

  13. Investigation of Metabolism of Exogenous Glucose at the Early Stage and Onset of Diabetes Mellitus in Otsuka Long-Evans Tokushima Fatty Rats Using [1, 2, 3-13C]Glucose Breath Tests

    PubMed Central

    Kijima, Sho; Tanaka, Hideki

    2016-01-01

    This study aimed to evaluate changes in glucose metabolism at the early stage and onset of diabetes in Otsuka Long-Evans Tokushima Fatty (OLETF) rats. Specifically, after the oral administration of [1, 2, 3-13C]glucose, the levels of exhaled 13CO2, which most likely originated from pyruvate decarboxylation and tricarboxylic acid, were measured. Eight OLETF rats and eight control rats (Long-Evans Tokushima Otsuka [LETO]) were administered 13C-glucose. Three types of 13C-glucose breath tests were performed thrice in each period at 2-week intervals. [3-13C]glucose results in a 13C isotope at position 1 in the pyruvate molecule, which provides 13CO2. The 13C at carbons 1 and 2 of glucose is converted to 13C at carbons 2 and 1 of acetate, respectively, which produce 13CO2. Based on metabolic differences of the labeled sites, glucose metabolism was evaluated using the results of three breath tests. The increase in 13CO2 excretion in OLETF rats was delayed in all three breath tests compared to that in control rats, suggesting that OLETF rats had a lower glucose metabolism than control rats. In addition, overall glucose metabolism increased with age in both groups. The utilization of [2-13C]glucose was suppressed in OLETF rats at 6–12 weeks of age, but they showed higher [3-13C]glucose oxidation than control rats at 22–25 weeks of age. In the [1-13C]glucose breath test, no significant differences in the area under the curve until 180 minutes (AUC180) were observed between OLETF and LETO rats of any age. Glucose metabolism kinetics were different between the age groups and two groups of rats; however, these differences were not significant based on the overall AUC180 of [1-13C]glucose. We conclude that breath 13CO2 excretion is reduced in OLETF rats at the primary stage of prediabetes, indicating differences in glucose oxidation kinetics between OLETF and LETO rats. PMID:27483133

  14. Investigation of Metabolism of Exogenous Glucose at the Early Stage and Onset of Diabetes Mellitus in Otsuka Long-Evans Tokushima Fatty Rats Using [1, 2, 3-13C]Glucose Breath Tests.

    PubMed

    Kawagoe, Naoyuki; Kano, Osamu; Kijima, Sho; Tanaka, Hideki; Takayanagi, Masaaki; Urita, Yoshihisa

    2016-01-01

    This study aimed to evaluate changes in glucose metabolism at the early stage and onset of diabetes in Otsuka Long-Evans Tokushima Fatty (OLETF) rats. Specifically, after the oral administration of [1, 2, 3-13C]glucose, the levels of exhaled 13CO2, which most likely originated from pyruvate decarboxylation and tricarboxylic acid, were measured. Eight OLETF rats and eight control rats (Long-Evans Tokushima Otsuka [LETO]) were administered 13C-glucose. Three types of 13C-glucose breath tests were performed thrice in each period at 2-week intervals. [3-13C]glucose results in a 13C isotope at position 1 in the pyruvate molecule, which provides 13CO2. The 13C at carbons 1 and 2 of glucose is converted to 13C at carbons 2 and 1 of acetate, respectively, which produce 13CO2. Based on metabolic differences of the labeled sites, glucose metabolism was evaluated using the results of three breath tests. The increase in 13CO2 excretion in OLETF rats was delayed in all three breath tests compared to that in control rats, suggesting that OLETF rats had a lower glucose metabolism than control rats. In addition, overall glucose metabolism increased with age in both groups. The utilization of [2-13C]glucose was suppressed in OLETF rats at 6-12 weeks of age, but they showed higher [3-13C]glucose oxidation than control rats at 22-25 weeks of age. In the [1-13C]glucose breath test, no significant differences in the area under the curve until 180 minutes (AUC180) were observed between OLETF and LETO rats of any age. Glucose metabolism kinetics were different between the age groups and two groups of rats; however, these differences were not significant based on the overall AUC180 of [1-13C]glucose. We conclude that breath 13CO2 excretion is reduced in OLETF rats at the primary stage of prediabetes, indicating differences in glucose oxidation kinetics between OLETF and LETO rats.

  15. 42 CFR 84.152 - Breathing tube test; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...: (i) Be employed on Type C supplied-air respirators of the demand and pressure-demand class; and (ii... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.152 Breathing tube test; minimum requirements. (a)(1) Type A and Type B supplied-air...

  16. Fourier-transformed infrared breath testing after ingestion of technical alcohol.

    PubMed

    Laakso, Olli; Haapala, Matti; Pennanen, Teemu; Kuitunen, Tapio; Himberg, Jaakko-Juhani

    2007-07-01

    The study aim was to evaluate the feasibility of a Fourier-transformed infrared (FT-IR) analyzer for out-of-laboratory use by screening the exhalations of inebriated individuals, and to determine analysis quality using common breath components and solvents. Each of the 35 inebriated participants gave an acceptable sample. Because of the metabolism of 2-propanol, the subjects exhaled high concentrations of acetone in addition to ethanol. Other volatile ingredients of technical ethanol products (methyl ethyl ketone, methyl isobutyl ketone, and 2-propanol) were also detected. The lower limits of quantification for the analyzed components ranged from 1.7 to 12 microg/L in simulated breath samples. The bias was +/-2% for ethanol and -11% for methanol. Within-day and between-day coefficients of variation were <1% for ethanol and <4% for methanol. The bias of ethanol and methanol analyses due to coexisting solvents ranged from -0.8 to +2.2% and from -5.6 to +2.9%, respectively. The FT-IR method proved suitable for use outside the laboratory and fulfilled the quality criteria for analysis of solvents in breath.

  17. When Breathing Interferes with Cognition: Experimental Inspiratory Loading Alters Timed Up-and-Go Test in Normal Humans.

    PubMed

    Nierat, Marie-Cécile; Demiri, Suela; Dupuis-Lozeron, Elise; Allali, Gilles; Morélot-Panzini, Capucine; Similowski, Thomas; Adler, Dan

    2016-01-01

    Human breathing stems from automatic brainstem neural processes. It can also be operated by cortico-subcortical networks, especially when breathing becomes uncomfortable because of external or internal inspiratory loads. How the "irruption of breathing into consciousness" interacts with cognition remains unclear, but a case report in a patient with defective automatic breathing (Ondine's curse syndrome) has shown that there was a cognitive cost of breathing when the respiratory cortical networks were engaged. In a pilot study of putative breathing-cognition interactions, the present study relied on a randomized design to test the hypothesis that experimentally loaded breathing in 28 young healthy subjects would have a negative impact on cognition as tested by "timed up-and-go" test (TUG) and its imagery version (iTUG). Progressive inspiratory threshold loading resulted in slower TUG and iTUG performance. Participants consistently imagined themselves faster than they actually were. However, progressive inspiratory loading slowed iTUG more than TUG, a finding that is unexpected with regard to the known effects of dual tasking on TUG and iTUG (slower TUG but stable iTUG). Insofar as the cortical networks engaged in response to inspiratory loading are also activated during complex locomotor tasks requiring cognitive inputs, we infer that competition for cortical resources may account for the breathing-cognition interference that is evidenced here.

  18. The Effect of Alcohol-Based Hand Sanitizer Vapors on Evidential Breath Alcohol Test Results.

    PubMed

    Strawsine, Ellen; Lutmer, Brian

    2017-11-16

    This study was undertaken to determine if the application of alcohol-based hand sanitizers (ABHSs) to the hands of a breath test operator will affect the results obtained on evidential breath alcohol instruments (EBTs). This study obtained breath samples on three different EBTs immediately after application of either gel or foam ABHS to the operator's hands. A small, but significant, number of initial analyses (13 of 130, 10%) resulted in positive breath alcohol concentrations, while 41 samples (31.5%) resulted in a status code. These status codes were caused by ethanol vapors either in the room air or their inhalation by the subject, thereby causing a mouth alcohol effect. Replicate subject samples did not yield any consecutive positive numeric results. As ABHS application can cause a transitory mouth alcohol effect via inhalation of ABHS vapors, EBT operators should forego the use of ABHS in the 15 min preceding subject testing. © 2017 American Academy of Forensic Sciences.

  19. Compressed air demand-type firefighter's breathing system, volume 1. [design analysis and performance tests

    NASA Technical Reports Server (NTRS)

    Sullivan, J. L.

    1975-01-01

    The commercial availability of lightweight high pressure compressed air vessels has resulted in a lightweight firefighter's breathing apparatus. The improved apparatus, and details of its design and development are described. The apparatus includes a compact harness assembly, a backplate mounted pressure reducer assembly, a lightweight bubble-type facemask with a mask mounted demand breathing regulator. Incorporated in the breathing regulator is exhalation valve, a purge valve and a whistle-type low pressure warning that sounds only during inhalation. The pressure reducer assembly includes two pressure reducers, an automatic transfer valve and a signaling device for the low pressure warning. Twenty systems were fabricated, tested, refined through an alternating development and test sequence, and extensively examined in a field evaluation program. Photographs of the apparatus are included.

  20. Chemical sensors for breath gas analysis: the latest developments at the Breath Analysis Summit 2013.

    PubMed

    Tisch, Ulrike; Haick, Hossam

    2014-06-01

    Profiling the body chemistry by means of volatile organic compounds (VOCs) in the breath opens exciting new avenues in medical diagnostics. Gas sensors could provide ideal platforms for realizing portable, hand-held breath testing devices in the near future. This review summarizes the latest developments and applications in the field of chemical sensors for diagnostic breath testing that were presented at the Breath Analysis Summit 2013 in Wallerfangen, Germany. Considerable progress has been made towards clinically applicable breath testing devices, especially by utilizing chemo-sensitive nanomaterials. Examples of several specialized breath testing applications are presented that are either based on stand-alone nanomaterial-based sensors being highly sensitive and specific to individual breath compounds over others, or on combinations of several highly specific sensors, or on experimental nanomaterial-based sensors arrays. Other interesting approaches include the adaption of a commercially available MOx-based sensor array to indirect breath testing applications, using a sample pre-concentration method, and the development of compact integrated GC-sensor systems. The recent trend towards device integration has led to the development of fully integrated prototypes of point-of-care devices. We describe and compare the performance of several prototypes that are based on different sensing technologies and evaluate their potential as low-cost and readily available next-generation medical devices.

  1. Sleep-Disordered Breathing and Mortality: A Prospective Cohort Study

    PubMed Central

    Punjabi, Naresh M.; Caffo, Brian S.; Goodwin, James L.; Gottlieb, Daniel J.; Newman, Anne B.; O'Connor, George T.; Rapoport, David M.; Redline, Susan; Resnick, Helaine E.; Robbins, John A.; Shahar, Eyal; Unruh, Mark L.; Samet, Jonathan M.

    2009-01-01

    Background Sleep-disordered breathing is a common condition associated with adverse health outcomes including hypertension and cardiovascular disease. The overall objective of this study was to determine whether sleep-disordered breathing and its sequelae of intermittent hypoxemia and recurrent arousals are associated with mortality in a community sample of adults aged 40 years or older. Methods and Findings We prospectively examined whether sleep-disordered breathing was associated with an increased risk of death from any cause in 6,441 men and women participating in the Sleep Heart Health Study. Sleep-disordered breathing was assessed with the apnea–hypopnea index (AHI) based on an in-home polysomnogram. Survival analysis and proportional hazards regression models were used to calculate hazard ratios for mortality after adjusting for age, sex, race, smoking status, body mass index, and prevalent medical conditions. The average follow-up period for the cohort was 8.2 y during which 1,047 participants (587 men and 460 women) died. Compared to those without sleep-disordered breathing (AHI: <5 events/h), the fully adjusted hazard ratios for all-cause mortality in those with mild (AHI: 5.0–14.9 events/h), moderate (AHI: 15.0–29.9 events/h), and severe (AHI: ≥30.0 events/h) sleep-disordered breathing were 0.93 (95% CI: 0.80–1.08), 1.17 (95% CI: 0.97–1.42), and 1.46 (95% CI: 1.14–1.86), respectively. Stratified analyses by sex and age showed that the increased risk of death associated with severe sleep-disordered breathing was statistically significant in men aged 40–70 y (hazard ratio: 2.09; 95% CI: 1.31–3.33). Measures of sleep-related intermittent hypoxemia, but not sleep fragmentation, were independently associated with all-cause mortality. Coronary artery disease–related mortality associated with sleep-disordered breathing showed a pattern of association similar to all-cause mortality. Conclusions Sleep-disordered breathing is associated with

  2. Sex Differences in the Prevalence and Modulators of Sleep-Disordered Breathing in Outpatients with Type 2 Diabetes

    PubMed Central

    Kroner, T.; Arzt, M.; Rheinberger, M.; Gorski, M.; Heid, I. M.; Böger, C. A.

    2018-01-01

    In patients with type 2 diabetes, sleep-disordered breathing is a widespread cause of deteriorated quality of life. However, robust prevalence estimates for sleep-disordered breathing in patients with type 2 diabetes are limited due to scarce data. We investigated sex differences in sleep-disordered breathing prevalence and its modulators in the DIACORE SDB substudy, a sample of outpatient type 2 diabetes. 721 participants were tested for sleep-disordered breathing using a two-channel sleep apnoea monitoring device. Patients were stratified according to the severity of sleep-disordered breathing, defined as an apnoea-hypopnoea index < 15, ≥15 to 29, and ≥30 events per hour as no/mild, moderate, and severe sleep-disordered breathing, respectively. In the 679 analysed patients (39% women, age 66 ± 9 years, body mass index 31.0 ± 5.4 kg/m2), the prevalence of sleep-disordered breathing was 34%. The prevalence of sleep-disordered breathing was higher in men than in women (41% versus 22%, p < 0.001) and increased with age (15%, 21%, and 30% in women and 35%, 40%, and 47% in men in those aged 18–59, 60–69, or ≥70, respectively; age trend p = 0.064 in women and p = 0.15 in men). In linear regression analysis, age, BMI, and waist-hip ratio were associated with apnoea-hypopnoea index. Modulators for higher apnoea-hypopnoea index seem to be similar in men and women. PMID:29805982

  3. Aspiration tests in aqueous foam using a breathing simulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Archuleta, M.M.

    1995-12-01

    Non-toxic aqueous foams are being developed by Sandia National Laboratories (SNL) for the National Institute of Justice (NIJ) for use in crowd control, cell extractions, and group disturbances in the criminal justice prison systems. The potential for aspiration of aqueous foam during its use and the resulting adverse effects associated with complete immersion in aqueous foam is of major concern to the NIJ when examining the effectiveness and safety of using this technology as a Less-Than-Lethal weapon. This preliminary study was designed to evaluate the maximum quantity of foam that might be aspirated by an individual following total immersion inmore » an SNL-developed aqueous foam. A.T.W. Reed Breathing simulator equipped with a 622 Silverman cam was used to simulate the aspiration of an ammonium laureth sulfate aqueous foam developed by SNL and generated at expansion ratios in the range of 500:1 to 1000:1. Although the natural instinct of an individual immersed in foam is to cover their nose and mouth with a hand or cloth, thus breaking the bubbles and decreasing the potential for aspiration, this study was performed to examine a worst case scenario where mouth breathing only was examined, and no attempt was made to block foam entry into the breathing port. Two breathing rates were examined: one that simulated a sedentary individual with a mean breathing rate of 6.27 breaths/minute, and one that simulated an agitated or heavily breathing individual with a mean breathing rate of 23.7 breaths/minute. The results of this study indicate that, if breathing in aqueous foam without movement, an air pocket forms around the nose and mouth within one minute of immersion.« less

  4. Respiratory responses of the air-breathing fish Hoplosternum littorale to hypoxia and hydrogen sulfide.

    PubMed

    Affonso, E G; Rantin, F T

    2005-07-01

    The present study analyzes the respiratory responses of the neotropical air-breathing fish Hoplosternum littorale to graded hypoxia and increased sulfide concentrations. The oxygen uptake (VO2), critical O2 tension (PcO2), respiratory (fR) and air-breathing (fRA) frequencies in response to graded hypoxia were determined for fish acclimated to 28 degrees C. H. littorale was able to maintain a constant VO2 down to a PcO2 of 50 mm Hg, below which fish became dependent on the environmental O2 even with significant increases in fR. The fRA was kept constant around 1 breath h(-1) above 50 mm Hg and increased significantly below 40 mm Hg, reaching maximum values (about 4.5 breaths h(-1)) at 10 mm Hg. The lethality to sulfide concentrations under normoxic and hypoxic conditions were also determined along with the fRA. For the normoxic fish the sulfide lethal limit was about 70 microM, while in the hypoxic ones this limit increased to 87 muM. The high sulfide tolerance of H. littorale may be attributed to the air-breathing capability, which is stimulated by this compound.

  5. Lactulose Breath Test Gas Production in Childhood IBS Is Associated With Intestinal Transit and Bowel Movement Frequency.

    PubMed

    Chumpitazi, Bruno P; Weidler, Erica M; Shulman, Robert J

    2017-04-01

    In adults with irritable bowel syndrome (IBS), bacterial gas production (colonic fermentation) is related to both symptom generation and intestinal transit. Whether gas production affects symptom generation, psychosocial distress, or intestinal transit in childhood IBS is unknown. Children (ages 7-17 years) with pediatric Rome III IBS completed validated psychosocial questionnaires and a 2-week daily diary capturing pain and stooling characteristics. Stool form determined IBS subtype. Subjects then completed a 3-hour lactulose breath test for measurement of total breath hydrogen and methane production. Carmine red was used to determine whole intestinal transit time. A total of 87 children (mean age 13 ± 2.6 [standard deviation] years) were enrolled, of whom 50 (57.5%) were girls. All children produced hydrogen and 51 (58.6%) produced methane. Hydrogen and methane production did not correlate with either abdominal pain frequency/severity or psychosocial distress. Hydrogen and methane production did not differ significantly by IBS subtype. Methane production correlated positively with whole intestinal transit time (r = 0.31, P < 0.005) and inversely with bowel movement frequency (r = -0.245, P < 0.05). Methane production (threshold 3 ppm) as a marker for identifying IBS-C had a sensitivity of 60% and specificity of 42.9%. Lactulose breath test total methane production may serve as a biomarker of whole intestinal transit time and bowel movement frequency in children with IBS. In children with IBS, lactulose breath test hydrogen and methane production did not, however, correlate with abdominal pain, IBS subtype, or psychosocial distress.

  6. Effect of Yogic Breathing on Accommodate Braille Version of Six-letter Cancellation Test in Students with Visual Impairment.

    PubMed

    Pradhan, Balaram; Mohanty, Soubhagyalaxmi; Hankey, Alex

    2018-01-01

    Attentional processes tend to be less well developed in the visually impaired, who require special training to develop them fully. Yogic breathing which alters the patterns of respiration has been shown to enhance attention skills. Letter cancellation tests are well-established tools to measure attention and attention span. Here, a modified Braille version of the six-letter cancellation test (SLCT) was used for students with visual impairment (VI). This study aimed to assess the immediate effects of Bhramari Pranayama (BhPr) and breath awareness (BA) on students with VI. This study was a self-as-control study held on 2 consecutive days, on 19 participants (8 males, 11 females), with a mean age of 15.89 ± 1.59 years, randomized into two groups. On the 1 st day, Group 1 performed 10 min breath awareness and Group 2 performed Bhramari ; on the 2 nd day, practices were reversed. Assessments used a SLCT specially adapted for the visually impaired before and after each session. The Braille letter cancellation test was successfully taken by 19 students. Scores significantly improved after both techniques for each student following practices on both days ( P < 0.001). BhPr may have more effect on attention performance than BA as wrong scores significantly increased following BA ( P < 0.05), but the increase in the score after Bhramari was not significant. Despite the small sample size improvement in attentional processes by both yoga breathing techniques was robust. Attentional skills were definitely enhanced. Long-term practice should be studied.

  7. Effect of Yogic Breathing on Accommodate Braille Version of Six-letter Cancellation Test in Students with Visual Impairment

    PubMed Central

    Pradhan, Balaram; Mohanty, Soubhagyalaxmi; Hankey, Alex

    2018-01-01

    Context: Attentional processes tend to be less well developed in the visually impaired, who require special training to develop them fully. Yogic breathing which alters the patterns of respiration has been shown to enhance attention skills. Letter cancellation tests are well-established tools to measure attention and attention span. Here, a modified Braille version of the six-letter cancellation test (SLCT) was used for students with visual impairment (VI). Aim: This study aimed to assess the immediate effects of Bhramari Pranayama (BhPr) and breath awareness (BA) on students with VI. Methods: This study was a self-as-control study held on 2 consecutive days, on 19 participants (8 males, 11 females), with a mean age of 15.89 ± 1.59 years, randomized into two groups. On the 1st day, Group 1 performed 10 min breath awareness and Group 2 performed Bhramari; on the 2nd day, practices were reversed. Assessments used a SLCT specially adapted for the visually impaired before and after each session. Results: The Braille letter cancellation test was successfully taken by 19 students. Scores significantly improved after both techniques for each student following practices on both days (P < 0.001). BhPr may have more effect on attention performance than BA as wrong scores significantly increased following BA (P < 0.05), but the increase in the score after Bhramari was not significant. Conclusions: Despite the small sample size improvement in attentional processes by both yoga breathing techniques was robust. Attentional skills were definitely enhanced. Long-term practice should be studied. PMID:29755219

  8. Training in multiple breath washout testing for respiratory physiotherapists.

    PubMed

    O'Neill, Katherine; Elborn, J Stuart; Tunney, Michael M; O'Neill, Philip; Rowan, Stephen; Martin, Susan; Bradley, Judy M

    2018-03-01

    The development of multiple breath washout (MBW) testing in respiratory disease highlights the need for increased awareness amongst respiratory physiotherapists and a potential opportunity for professional development in the use of an important outcome measure for clinical trials. To rationalise how MBW may be a useful assessment tool for respiratory physiotherapists and to describe a local MBW training and certification programme for physiotherapists. The respiratory Multidisciplinary Team in the Belfast Health and Social Care Trust (BHSCT) identified a need for MBW testing to be available to facilitate clinical research and assessment. A 2day training programme consisting of prereading preparation, self-directed learning, theory presentations, practical demonstrations and hands-on practice was developed and delivered. All participants underwent a certification process. We have demonstrated the successful training and certification of clinical and research physiotherapists and encourage other respiratory physiotherapists to consider MBW test training. Copyright © 2017 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  9. 13C-methacetin-breath test compared to also noninvasive biochemical blood tests in predicting hepatic fibrosis and cirrhosis in chronic hepatitis C.

    PubMed

    Dinesen, L; Caspary, W F; Chapman, R W; Dietrich, C F; Sarrazin, C; Braden, B

    2008-09-01

    The (13)C-methacetin-breath test and also several noninvasive blood tests comprising routine laboratory parameters have been proposed to predict fibrosis and cirrhosis in chronic hepatitis C. The aim of the study was to compare the diagnostic accuracy between these tests referring to hepatic histology as gold standard. 96 patients with chronic hepatitis C virus infection underwent percutaneous liver biopsy and the (13)C-methacetin-breath test. The Fibroindex, the aspartate aminotransferase to platelet ratio index , and the aspartate aminotransferase to alanine aminotransferase ratio were used as parameters for the staging of fibrosis. The main endpoint was the area under the characteristic curves for the diagnosis of advanced fibrosis (F3-F4) and cirrhosis (F4) according to the Batts Ludwig criteria. ROC analysis revealed a cut-off <14.6 per thousand best with 92.6% sensitivity and 84.1% specificity for the (13)C-methacetin-breath test, for the Fibroindex >1.82 70.4% sensitivity and 91.3% specificity, for the aspartate aminotransferase to platelet ratio >1.0 a 66.7% sensitivity and 75.4% specificity, and for the aspartate aminotransferase to alanine aminotransferase ratio >1.0 63.0% sensitivity and 59.4% specificity in predicting liver cirrhosis. The areas under the curve for the breath test, the Fibroindex, aspartate aminotransferase to platelet ratio and the aspartate aminotransferase to alanine aminotransferase ratio were 0.958, 0.845, 0.799, and 0.688, respectively, when predicting cirrhosis. For identifying patients with advanced fibrosis, the areas under the curve were 0.827, 0.804, 0.779, and 0.561, respectively. Discordances between Fibroindex (21%), aspartate aminotransferase to platelet ratio (29%) or aspartate aminotransferase to alanine aminotransferase ratio (37.6%) and liver biopsy were significantly more frequent than between (13)C-breath test (11.6%) and liver biopsy (P<0.05). The (13)C-methacetin-breath test is more reliable in predicting advanced

  10. A simplified urea breath test for the diagnosis of Helicobacter pylori infection using the LARA System. Laser Assisted Ratio Analyzer.

    PubMed

    Minoli, G; Prada, A; Schuman, R; Murnick, D; Rigas, B

    1998-06-01

    Helicobacter pylori, one of the most prevalent human pathogens, is associated with chronic gastritis, peptic ulcer disease, and possibly gastric cancer and primary gastric lymphoma. The need to treat these patients has necessitated the development of improved methods to diagnose H. pylori infection. We present the preliminary assessment of a 13C-urea breath test (UBT) in which the expired 13CO2 is detected in a rapid, simple, inexpensive way by the LARA (Laser Assisted Ratio Analyzer) System (Alimenterics, Inc., Morris Plains, NJ). Eighty-seven consecutive patients, examined for upper gastrointestinal symptoms, underwent endoscopy. H. pylori infection was established by antral biopsies and a rapid urease test (CLOtest). The UBT was performed between 2 and 24 hours after endoscopy. Of the 84 analyzable patients, 70 were found to be H. pylori-positive either by histology or by CLOtest. All 70 were positive by the LARA UBT, yielding a sensitivity of 100%. Fourteen patients were negative for H. pylori by histology and the CLOtest. Of these, 12 were negative by the LARA UBT and 2 were positive, yielding a specificity of 85.7%; because of the limitations of H. pylori detection by histology or urease assays, however, the specificity of the UBT may have been underestimated. Our study demonstrates the feasibility of a nonradioactive, rapid UBT based on the LARA system and suggests the need for its more detailed evaluation.

  11. In vitro evaluation of heat and moisture exchangers designed for spontaneously breathing tracheostomized patients.

    PubMed

    Brusasco, Claudia; Corradi, Francesco; Vargas, Maria; Bona, Margherita; Bruno, Federica; Marsili, Maria; Simonassi, Francesca; Santori, Gregorio; Severgnini, Paolo; Kacmarek, Robert M; Pelosi, Paolo

    2013-11-01

    Heat and moisture exchangers (HMEs) are commonly used in chronically tracheostomized spontaneously breathing patients, to condition inhaled air, maintain lower airway function, and minimize the viscosity of secretions. Supplemental oxygen (O2) can be added to most HMEs designed for spontaneously breathing tracheostomized patients. We tested the efficiency of 7 HMEs designed for spontaneously breathing tracheostomized patients, in a normothermic model, at different minute ventilations (VE) and supplemental O2 flows. HME efficiency was evaluated using an in vitro lung model at 2 VE (5 and 15 L/min) and 4 supplemental O2 flows (0, 3, 6, and 12 L/min). Wet and dry temperatures of the inspiratory flow were measured, and absolute humidity was calculated. In addition, HME efficiency at 0, 12, and 24 h use was evaluated, as well as resistance to flow at 0 and 24 h. The progressive increase in O2 flow from 0 to 12 L/min was associated with a reduction in temperature and absolute humidity. Under the same conditions, this effect was greater at lower VE. The HME with the best performance provided an absolute humidity of 26 mg H2O/L and a temperature of 27.8 °C. No significant changes in efficiency or resistance were detected during the 24 h evaluation. The efficiency of HMEs in terms of temperature and absolute humidity is significantly affected by O2 supplementation and V(E).

  12. A nanomaterial-based breath test for distinguishing gastric cancer from benign gastric conditions.

    PubMed

    Xu, Z-q; Broza, Y Y; Ionsecu, R; Tisch, U; Ding, L; Liu, H; Song, Q; Pan, Y-y; Xiong, F-x; Gu, K-s; Sun, G-p; Chen, Z-d; Leja, M; Haick, H

    2013-03-05

    Upper digestive endoscopy with biopsy and histopathological evaluation of the biopsy material is the standard method for diagnosing gastric cancer (GC). However, this procedure may not be widely available for screening in the developing world, whereas in developed countries endoscopy is frequently used without major clinical gain. There is a high demand for a simple and non-invasive test for selecting the individuals at increased risk that should undergo the endoscopic examination. Here, we studied the feasibility of a nanomaterial-based breath test for identifying GC among patients with gastric complaints. Alveolar exhaled breath samples from 130 patients with gastric complaints (37 GC/32 ulcers / 61 less severe conditions) that underwent endoscopy/biopsy were analyzed using nanomaterial-based sensors. Predictive models were built employing discriminant factor analysis (DFA) pattern recognition, and their stability against possible confounding factors (alcohol/tobacco consumption; Helicobacter pylori) was tested. Classification success was determined (i) using leave-one-out cross-validation and (ii) by randomly blinding 25% of the samples as a validation set. Complementary chemical analysis of the breath samples was performed using gas chromatography coupled with mass spectrometry. Three DFA models were developed that achieved excellent discrimination between the subpopulations: (i) GC vs benign gastric conditions, among all the patients (89% sensitivity; 90% specificity); (ii) early stage GC (I and II) vs late stage (III and IV), among GC patients (89% sensitivity; 94% specificity); and (iii) ulcer vs less severe, among benign conditions (84% sensitivity; 87% specificity). The models were insensitive against the tested confounding factors. Chemical analysis found that five volatile organic compounds (2-propenenitrile, 2-butoxy-ethanol, furfural, 6-methyl-5-hepten-2-one and isoprene) were significantly elevated in patients with GC and/or peptic ulcer, as compared

  13. Validation of 13C-acetic acid breath test by measuring effects of loperamide, morphine, mosapride, and itopride on gastric emptying in mice.

    PubMed

    Matsumoto, Kenjiro; Kimura, Hiroshi; Tashima, Kimihito; Uchida, Masayuki; Horie, Syunji

    2008-10-01

    Several methods are used to evaluate gastric motility in rodents, but they all have technical limitations. Recent technical developments enable a convenient method to evaluate gastric motility. The (13)C-acetic acid breath test in rodents is a non-invasive and repeatable method that can be used without physical restraints. The present study aimed to validate the (13)C-acetic acid breath test by measuring the effects of loperamide, morphine, mosapride, and itopride on gastric emptying in mice. Loperamide (1-10 mg/kg) and morphine (1.25-10 mg/kg) slowed gastric emptying and decreased the maximum concentration (C(max)) and area under the curve (AUC(90 min)) value in a dose-dependent manner. Mosapride (0.2-5 mg/kg) accelerated gastric emptying and increased C(max) value. Mosapride (20 mg/kg) did not accelerate gastric emptying on the (13)C-breath test. Itopride (30 mg/kg, per os) significantly accelerated gastric emptying compared with the vehicle group. In a comparison with the conventional phenol red test, there was a correlation between the C(max) value of breath test and gastric emptying (%) of phenol red tests in treatment with loperamide or mosapride. These results indicate that the (13)C-acetic acid breath test is an accurate, noninvasive, and simple method for monitoring gastric emptying in mice. This method is useful to assess the effect of drugs and gut function pharmacologically.

  14. Four-sample lactose hydrogen breath test for diagnosis of lactose malabsorption in irritable bowel syndrome patients with diarrhea

    PubMed Central

    Yang, Jian-Feng; Fox, Mark; Chu, Hua; Zheng, Xia; Long, Yan-Qin; Pohl, Daniel; Fried, Michael; Dai, Ning

    2015-01-01

    AIM: To validate 4-sample lactose hydrogen breath testing (4SLHBT) compared to standard 13-sample LHBT in the clinical setting. METHODS: Irritable bowel syndrome patients with diarrhea (IBS-D) and healthy volunteers (HVs) were enrolled and received a 10 g, 20 g, or 40 g dose lactose hydrogen breath test (LHBT) in a randomized, double-blinded, controlled trial. The lactase gene promoter region was sequenced. Breath samples and symptoms were acquired at baseline and every 15 min for 3 h (13 measurements). The detection rates of lactose malabsorption (LM) and lactose intolerance (LI) for a 4SLHBT that acquired four measurements at 0, 90, 120, and 180 min from the same data set were compared with the results of standard LHBT. RESULTS: Sixty IBS-D patients and 60 HVs were studied. The genotype in all participants was C/C-13910. LM and LI detection rates increased with lactose dose from 10 g, 20 g to 40 g in both groups (P < 0.001). 4SLHBT showed excellent diagnostic concordance with standard LHBT (97%-100%, Kappa​​ 0.815-0.942) with high sensitivity (90%-100%) and specificity (100%) at all three lactose doses in both groups. CONCLUSION: Reducing the number of measurements from 13 to 4 samples did not significantly impact on the accuracy of LHBT in health and IBS-D. 4SLHBT is a valid test for assessment of LM and LI in clinical practice. PMID:26140004

  15. Four-sample lactose hydrogen breath test for diagnosis of lactose malabsorption in irritable bowel syndrome patients with diarrhea.

    PubMed

    Yang, Jian-Feng; Fox, Mark; Chu, Hua; Zheng, Xia; Long, Yan-Qin; Pohl, Daniel; Fried, Michael; Dai, Ning

    2015-06-28

    To validate 4-sample lactose hydrogen breath testing (4SLHBT) compared to standard 13-sample LHBT in the clinical setting. Irritable bowel syndrome patients with diarrhea (IBS-D) and healthy volunteers (HVs) were enrolled and received a 10 g, 20 g, or 40 g dose lactose hydrogen breath test (LHBT) in a randomized, double-blinded, controlled trial. The lactase gene promoter region was sequenced. Breath samples and symptoms were acquired at baseline and every 15 min for 3 h (13 measurements). The detection rates of lactose malabsorption (LM) and lactose intolerance (LI) for a 4SLHBT that acquired four measurements at 0, 90, 120, and 180 min from the same data set were compared with the results of standard LHBT. Sixty IBS-D patients and 60 HVs were studied. The genotype in all participants was C/C-13910. LM and LI detection rates increased with lactose dose from 10 g, 20 g to 40 g in both groups (P < 0.001). 4SLHBT showed excellent diagnostic concordance with standard LHBT (97%-100%, Kappa​​ 0.815-0.942) with high sensitivity (90%-100%) and specificity (100%) at all three lactose doses in both groups. Reducing the number of measurements from 13 to 4 samples did not significantly impact on the accuracy of LHBT in health and IBS-D. 4SLHBT is a valid test for assessment of LM and LI in clinical practice.

  16. Evaluation of portable breath test devices for screening suspected drunken drivers by police in Hennepin County, Minnesota

    DOT National Transportation Integrated Search

    1974-06-01

    This evaluation report examines use in the field of portable breath test (PBT) devices by police in Hennepin County, Minnesota. Thirteen Brog-Warner J2 and J2A-200 "ALERT" devices were deployed by seven enforcement agencies. This report is presented ...

  17. Spontaneous breathing during lung-protective ventilation in an experimental acute lung injury model: high transpulmonary pressure associated with strong spontaneous breathing effort may worsen lung injury.

    PubMed

    Yoshida, Takeshi; Uchiyama, Akinori; Matsuura, Nariaki; Mashimo, Takashi; Fujino, Yuji

    2012-05-01

    We investigated whether potentially injurious transpulmonary pressure could be generated by strong spontaneous breathing and exacerbate lung injury even when plateau pressure is limited to <30 cm H2O. Prospective, randomized, animal study. University animal research laboratory. Thirty-two New Zealand White rabbits. Lavage-injured rabbits were randomly allocated to four groups to receive low or moderate tidal volume ventilation, each combined with weak or strong spontaneous breathing effort. Inspiratory pressure for low tidal volume ventilation was set at 10 cm H2O and tidal volume at 6 mL/kg. For moderate tidal volume ventilation, the values were 20 cm H2O and 7-9 mL/kg. The groups were: low tidal volume ventilation+spontaneous breathingweak, low tidal volume ventilation+spontaneous breathingstrong, moderate tidal volume ventilation+spontaneous breathingweak, and moderate tidal volume ventilation+spontaneous breathingstrong. Each group had the same settings for positive end-expiratory pressure of 8 cm H2O. Respiratory variables were measured every 60 mins. Distribution of lung aeration and alveolar collapse were histologically evaluated. Low tidal volume ventilation+spontaneous breathingstrong showed the most favorable oxygenation and compliance of respiratory system, and the best lung aeration. By contrast, in moderate tidal volume ventilation+spontaneous breathingstrong, the greatest atelectasis with numerous neutrophils was observed. While we applied settings to maintain plateau pressure at <30 cm H2O in all groups, in moderate tidal volume ventilation+spontaneous breathingstrong, transpulmonary pressure rose >33 cm H2O. Both minute ventilation and respiratory rate were higher in the strong spontaneous breathing groups. Even when plateau pressure is limited to <30 cm H2O, combined with increased respiratory rate and tidal volume, high transpulmonary pressure generated by strong spontaneous breathing effort can worsen lung injury. When spontaneous breathing is

  18. 21 CFR 862.1120 - Blood gases (PCO2, PO2) and blood pH test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood gases (PCO2, PO2) and blood pH test system... Test Systems § 862.1120 Blood gases (PCO2, PO2) and blood pH test system. (a) Identification. A blood gases (PCO2, PO2) and blood pH test system is a device intended to measure certain gases in blood, serum...

  19. 26 CFR 1.501(h)-2 - Electing the expenditure test.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 7 2010-04-01 2010-04-01 true Electing the expenditure test. 1.501(h)-2 Section 1.501(h)-2 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Exempt Organizations § 1.501(h)-2 Electing the expenditure...

  20. ALS LOX/H2 subscale coaxial injector testing

    NASA Technical Reports Server (NTRS)

    Dexter, Carol E.

    1991-01-01

    Tests of a 40K subscale LOX/H2 coaxial LOX swirl injector conducted without injector or chamber degradation are reported. Chamber pressures ranged from 1572 to 2355 psia with overall mixture ratios from 5.04 to 6.39. The highest characteristic velocities were measured when the mixture ratio across the injector face was uniform. Scarfing of the outer row LOX posts had the largest effect on chamber heating rates. As a result of the tests, the LSI design was modified to arrange the outer row LOX posts in a circular pattern, eliminate O/F biasing and fuel film cooling, and modify the interpropellant plate to allow for larger pressure differentials during the start and cutoff transients. Testing of a 100 K LOX/H2 coaxial LOX swirl injector involved chamber pressure ranging from 700 to 2500 psia with overall mixture ratios from 3.2 to 8.8. Stable combustion was observed to a fuel temperature of 90R and characteristic velocity efficiencies were good.

  1. Hubble Space Telescope NiH2 six battery test

    NASA Technical Reports Server (NTRS)

    Whitt, Thomas H.; Lanier, J. Roy

    1991-01-01

    The primary objectives of the test are: (1) to get a better understanding of the operating characteristics of the NiH2 batteries in the Hubble Space Telescope (HST) Electric Power Subsystem (EPS) by simulating every aspect of the expected operating environment; (2) to determine the optimum charge level and charge scheme for the NiH2 batteries in the HST EPS; (3) to predict the performance of the actual HST EPS; (4) to observe the aging characteristics of the batteries; and (5) to test different EPS anomalies before experiencing the anomalies on the actual HST.

  2. Stable Breathing in Patients With Obstructive Sleep Apnea Is Associated With Increased Effort but Not Lowered Metabolic Rate.

    PubMed

    de Melo, Camila M; Taranto-Montemurro, Luigi; Butler, James P; White, David P; Loring, Stephen H; Azarbarzin, Ali; Marques, Melania; Berger, Philip J; Wellman, Andrew; Sands, Scott A

    2017-10-01

    In principle, if metabolic rate were to fall during sleep in a patient with obstructive sleep apnea (OSA), ventilatory requirements could be met without increased respiratory effort thereby favoring stable breathing. Indeed, most patients achieve periods of stable flow-limited breathing without respiratory events for periods during the night for reasons that are unclear. Thus, we tested the hypothesis that in patients with OSA, periods of stable breathing occur when metabolic rate (VO2) declines. Twelve OSA patients (apnea-hypopnea index >15 events/h) completed overnight polysomnography including measurements of VO2 (using ventilation and intranasal PO2) and respiratory effort (esophageal pressure). Contrary to our hypothesis, VO2 did not differ between stable and unstable breathing periods in non-REM stage 2 (208 ± 20 vs. 213 ± 18 mL/min), despite elevated respiratory effort during stable breathing (26 ± 2 versus 23 ± 2 cmH2O, p = .03). However, VO2 was lowered during deeper sleep (244 to 179 mL/min from non-REM stages 1 to 3, p = .04) in conjunction with more stable breathing. Further analysis revealed that airflow obstruction curtailed metabolism in both stable and unstable periods, since CPAP increased VO2 by 14% in both cases (p = .02, .03, respectively). Patients whose VO2 fell most during sleep avoided an increase in PCO2 and respiratory effort. OSA patients typically convert from unstable to stable breathing without lowering metabolic rate. During sleep, OSA patients labor with increased respiratory effort but fail to satisfy metabolic demand even in the absence of overt respiratory events. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  3. Effect of alcohol consumption on the liver detoxication capacity as measured by [13C2]aminopyrine and L-[1-13C]phenylalanine breath tests.

    PubMed

    Wutzke, Klaus D; Wigger, Marianne

    2009-09-01

    The aim of this study was to investigate the hepatic microsomal and cytosolic functions by using the 13CO2 breath test in healthy subjects either before or after consumption of red wine. Twelve adults received [13C2]aminopyrine and L-[1-13C]phenylalanine together with a standardised dinner. Expired air samples were taken over 6 h. After a wash-out period, the subjects consumed 0.4 ml ethanol per kg per day together with dinner over a 7.5-day period on average. Thereafter, 13C-tracer administration was repeated under identical conditions. The 13CO2 enrichments were measured by isotope ratio mass spectrometry. The mean cumulative percentage 13C-dose recovery after administration of [13C2]aminopyrine and L-[1-13C]phenylalanine either without or with red wine consumption amounted to 17.0+/-4.4 vs. 14.7+/-3.1% (p=0.170) and 14.0+/-2.8 vs. 11.5+/-3.9% (p=0.084), respectively. Moderate alcohol consumption does not induce significant short-term changes of the microsomal and the cytosolic function of the human liver in healthy subjects.

  4. Exercise training improves breathing strategy and performance during the six-minute walk test in obese adolescents.

    PubMed

    Mendelson, Monique; Michallet, Anne-Sophie; Perrin, Claudine; Levy, Patrick; Wuyam, Bernard; Flore, Patrice

    2014-08-15

    We aimed to examine ventilatory responses during the six-minute walk test in healthy-weight and obese adolescents before and after exercise training. Twenty obese adolescents (OB) (age: 14.5±1.7 years; BMI: 34.0±4.7kg·m(-2)) and 20 age and gender-matched healthy-weight adolescents (HW) (age: 15.5±1.5 years; BMI: 19.9±1.4kg·m(-2)) completed six-minute walk test during which breath-by-breath gas analysis and expiratory flow limitation (expFL) were measured. OB participated in a 12-week exercise-training program. Comparison between HW and OB participants showed lower distance achieved during the 6MWT in OB (-111.0m, 95%CI: -160.1 to 62.0, p<0.05) and exertional breathlessness was greater (+0.78 a.u., 95%CI: 0.091-3.27, p=0.039) when compared with HW. Obese adolescents breathed at lower lung volumes, as evidenced by lower end expiratory and end inspiratory lung volumes during exercise (p<0.05). Prevalence of expFL (8 OB vs 2 HW, p=0.028) and mean expFL (14.9±21.9 vs 5.32±14.6% VT, p=0.043, in OB and HW) were greater in OB. After exercise training, mean increase in the distance achieved during the 6MWT was 64.5 meters (95%CI: 28.1-100.9, p=0.014) and mean decrease in exertional breathlessness was 1.62 (95%CI: 0.47-2.71, p=0.05). Obese adolescents breathed at higher lung volumes, as evidenced by the increase in end inspiratory lung volume from rest to 6-min exercise (9.9±13.4 vs 20.0±13.6%TLC, p<0.05). Improved performance was associated with improved change in end inspiratory lung volume from rest to 6-min exercise (r=0.65, p=0.025). Our results suggest that exercise training can improve breathing strategy during submaximal exercise in obese adolescents and that this increase is associated with greater exercise performance. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Influence of breathing resistance of heat and moisture exchangers on tracheal climate and breathing pattern in laryngectomized individuals.

    PubMed

    Scheenstra, Renske J; Muller, Sara H; Vincent, Andrew; Sinaasappel, Michiel; Hilgers, Frans J M

    2010-08-01

    The aim of this study was to determine the influence of breathing resistance of heat and moisture exchangers (HMEs) on endotracheal climate and breathing pattern. Endotracheal temperature and humidity and tidal volumes were measured in 11 laryngectomized patients with a regularly used HME with "standard" breathing resistance (Provox Normal HME; R-HME), a low breathing-resistance HME (Provox HiFlow HME; L-HME), and without HME. Both R-HME and L-HME increased end-inspiratory humidity (+5.8 and 4.7 mgH(2)O/L, respectively), decreased end-inspiratory temperature (-1.6 and -1.0 degrees C, respectively), and prolonged the exhalation breath length to approximately 0.5 seconds. The R-HME significantly enlarged tidal volumes (0.07 L; p < .05). Both HMEs significantly improve tracheal climate. The R-HME has better moistening properties and a small but significant positive effect on tidal volume. Therefore, if the higher resistance is tolerated, the R-HME is the preferred pulmonary rehabilitation device. The L-HME is indicated if lower breathing resistance is required. 2009 Wiley Periodicals, Inc. Head Neck, 2010.

  6. Hypoxic cardiorespiratory reflexes in the facultative air-breathing fish jeju (Hoplerythrinus unitaeniatus): role of branchial O2 chemoreceptors.

    PubMed

    Lopes, Jane Mello; Boijink, Cheila de Lima; Florindo, Luiz Henrique; Leite, Cleo Alcantara Costa; Kalinin, Ana Lúcia; Milsom, William K; Rantin, Francisco Tadeu

    2010-08-01

    In one series of experiments, heart frequency (f (H)), blood pressure (P (a)), gill ventilation frequency (f ( R )), ventilation amplitude (V (AMP)) and total gill ventilation (V (TOT)) were measured in intact jeju (Hoplerythrinus unitaeniatus) and jeju with progressive denervation of the branchial branches of cranial nerves IX (glossopharyngeal) and X (vagus) without access to air. When these fish were submitted to graded hypoxia (water PO(2) approximately 140, normoxia to 17 mmHg, severe hypoxia), they increased f ( R ), V (AMP), V (TOT) and P (a) and decreased f (H). In a second series of experiments, air-breathing frequency (f (RA)), measured in fish with access to the surface, increased with graded hypoxia. In both series, bilateral denervation of all gill arches eliminated the responses to graded hypoxia. Based on the effects of internal (caudal vein, 150 microg NaCN in 0.2 mL saline) and external (buccal) injections of NaCN (500 microg NaCN in 1.0 mL water) on f (R), V (AMP), V (TOT), P (a) and f (H) we conclude that the O(2) receptors involved in eliciting changes in gill ventilation and associated cardiovascular responses are present on all gill arches and monitor the O(2) levels of both inspired water and blood perfusing the gills. We also conclude that air breathing arises solely from stimulation of branchial chemoreceptors and support the hypothesis that internal hypoxaemia is the primary drive to air breathing.

  7. The autonomic control and functional significance of the changes in heart rate associated with air breathing in the jeju, Hoplerythrinus unitaeniatus.

    PubMed

    McKenzie, D J; Campbell, H A; Taylor, E W; Micheli, M; Rantin, F T; Abe, A S

    2007-12-01

    The jeju is a teleost fish with bimodal respiration that utilizes a modified swim bladder as an air-breathing organ (ABO). Like all air-breathing fish studied to date, jeju exhibit pronounced changes in heart rate (fH) during air-breathing events, and it is believed that these may facilitate oxygen uptake (MO2) from the ABO. The current study employed power spectral analysis (PSA) of fH patterns, coupled with instantaneous respirometry, to investigate the autonomic control of these phenomena and their functional significance for the efficacy of air breathing. The jeju obtained less than 5% of total MO2 (MtO2) from air breathing in normoxia at 26 degrees C, and PSA of beat-to-beat variability in fH revealed a pattern similar to that of unimodal water-breathing fish. In deep aquatic hypoxia (water PO2)=1 kPa) the jeju increased the frequency of air breathing (fAB) tenfold and maintained MtO2 unchanged from normoxia. This was associated with a significant increase in heart rate variability (HRV), each air breath (AB) being preceded by a brief bradycardia and then followed by a brief tachycardia. These fH changes are qualitatively similar to those associated with breathing in unimodal air-breathing vertebrates. Within 20 heartbeats after the AB, however, a beat-to-beat variability in fH typical of water-breathing fish was re-established. Pharmacological blockade revealed that both adrenergic and cholinergic tone increased simultaneously prior to each AB, and then decreased after it. However, modulation of inhibitory cholinergic tone was responsible for the major proportion of HRV, including the precise beat-to-beat modulation of fH around each AB. Pharmacological blockade of all variations in fH associated with air breathing in deep hypoxia did not, however, have a significant effect upon fAB or the regulation of MtO2. Thus, the functional significance of the profound HRV during air breathing remains a mystery.

  8. Light-Triggered CO2 Breathing Foam via Nonsurfactant High Internal Phase Emulsion.

    PubMed

    Zhang, Shiming; Wang, Dingguan; Pan, Qianhao; Gui, Qinyuan; Liao, Shenglong; Wang, Yapei

    2017-10-04

    Solid materials for CO 2 capture and storage have attracted enormous attention for gaseous separation, environmental protection, and climate governance. However, their preparation and recovery meet the problems of high energy and financial cost. Herein, a controllable CO 2 capture and storage process is accomplished in an emulsion-templated polymer foam, in which CO 2 is breathed-in under dark and breathed-out under light illumination. Such a process is likely to become a relay of natural CO 2 capture by plants that on the contrary breathe out CO 2 at night. Recyclable CO 2 capture at room temperature and release under light irradiation guarantee its convenient and cost-effective regeneration in industry. Furthermore, CO 2 mixed with CH 4 is successfully separated through this reversible breathing in and out system, which offers great promise for CO 2 enrichment and practical methane purification.

  9. Hypothyroidism Affects D2 Receptor-mediated Breathing without altering D2 Receptor Expression

    PubMed Central

    Schlenker, Evelyn H.; Rio, Rodrigo Del; Schultz, Harold D.

    2015-01-01

    Bromocriptine depressed ventilation in air and D2 receptor expression in the nucleus tractus solitaries (NTS) in male hypothyroid hamsters. Here we postulated that in age- matched hypothyroid female hamsters, the pattern of D2 receptor modulation of breathing and D2 receptor expression would differ from those reported in hypothyroid males. In females hypothyroidism did not affect D2 receptor protein levels in the NTS, carotid bodies or striatum. Bromocriptine, but not carmoxirole (a peripheral D2 receptor agonist), increased oxygen consumption and body temperature in awake air-exposed hypothyroid female hamsters and stimulated their ventilation before and following exposure to hypoxia. Carmoxirole depressed frequency of breathing in euthyroid hamsters prior to, during and following hypoxia exposures and stimulated it in the hypothyroid hamsters following hypoxia. Although hypothyroidism did not affect expression of D2 receptors, it influenced central D2 modulation of breathing in a disparate manner relative to euthyroid hamsters. PMID:24434437

  10. Hypothyroidism affects D2 receptor-mediated breathing without altering D2 receptor expression.

    PubMed

    Schlenker, Evelyn H; Del Rio, Rodrigo; Schultz, Harold D

    2014-03-01

    Bromocriptine depressed ventilation in air and D2 receptor expression in the nucleus tractus solitaries (NTS) in male hypothyroid hamsters. Here we postulated that in age-matched hypothyroid female hamsters, the pattern of D2 receptor modulation of breathing and D2 receptor expression would differ from those reported in hypothyroid males. In females hypothyroidism did not affect D2 receptor protein levels in the NTS, carotid bodies or striatum. Bromocriptine, but not carmoxirole (a peripheral D2 receptor agonist), increased oxygen consumption and body temperature in awake air-exposed hypothyroid female hamsters and stimulated their ventilation before and following exposure to hypoxia. Carmoxirole depressed frequency of breathing in euthyroid hamsters prior to, during and following hypoxia exposures and stimulated it in the hypothyroid hamsters following hypoxia. Although hypothyroidism did not affect expression of D2 receptors, it influenced central D2 modulation of breathing in a disparate manner relative to euthyroid hamsters. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Comparison of Accuracy Between 13C- and 14C-Urea Breath Testing: Is an Indeterminate-Results Category Still Needed?

    PubMed

    Charest, Mathieu; Bélair, Marc-André

    2017-06-01

    Helicobacter pylori infection is the leading cause of peptic ulcer disease. The purpose of this study was, first, to assess the difference in the distribution of negative versus positive results between the older 14 C-urea breath test and the newer 13 C-urea breath test and, second, to determine whether use of an indeterminate-results category is still meaningful and what type of results should trigger repeated testing. Methods: A retrospective survey was performed of all consecutive patients referred to our service for urea breath testing. We analyzed 562 patients who had undergone testing with 14 C-urea and 454 patients who had undergone testing with 13 C-urea. Results: In comparison with the wide distribution of negative 14 C results, negative 13 C results were distributed farther from the cutoff and were grouped more tightly around the mean negative value. Distribution analysis of the negative results for 13 C testing, compared with those for 14 C testing, revealed a statistically significant difference between the two. Within the 13 C group, only 1 patient could have been classified as having indeterminate results using the same indeterminate zone as was used for the 14 C group. This is significantly less frequent than what was found for the 14 C group. Discussion: Borderline-negative results do occur with 13 C-urea breath testing, although less frequently than with 14 C-urea breath testing, and we will be carefully monitoring differences falling between 3.0 and 3.5 %Δ. 13 C-urea breath testing is safe and simple for the patient and, in most cases, provides clearer positive or negative results for the clinician. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  12. Gravitational independence of single-breath washout tests in recumbent dogs

    NASA Technical Reports Server (NTRS)

    Tomioka, Shinichi; Kubo, Susumu; Guy, Harold J. B.; Prisk, G. K.

    1988-01-01

    The effect of gravitational orientation in the mechanism of lung filling and emptying in dogs was examined by conducting simultaneously Ar-bolus and N2 single-breath washout tests (SBWTs) in 10 anesthetized dogs (prone and supine), with three of the dogs subjected to body rotation. Transpulmonary pressure was measured simultaneously, allowing identification of the lung volume above residual volume at which there was an inflection point in the pressure-volume curve. Combined resident gas and bolus SBWTs in recumbent dogs were found to be different from such tests in humans; in dogs, the regional distribution of ventilation was not primarily determined by gravity. The measurements did not make it possible to discern exact mechanisms of filling and emptying, but both processes appear to be related to lung, thorax, and mediastinum interactions and/or differences in regional mechanical properties of the lungs.

  13. 2-Aminoacetophenone as a potential breath biomarker for Pseudomonas aeruginosa in the cystic fibrosis lung

    PubMed Central

    2010-01-01

    Background Pseudomonas aeruginosa infections are associated with progressive life threatening decline of lung function in cystic fibrosis sufferers. Growth of Ps. aeruginosa releases a "grape-like" odour that has been identified as the microbial volatile organic compound 2-aminoacetophenone (2-AA). Methods We investigated 2-AA for its specificity to Ps. aeruginosa and its suitability as a potential breath biomarker of colonisation or infection by Solid Phase Micro Extraction and Gas Chromatography-Mass Spectrometry (GC/MS). Results Cultures of 20 clinical strains of Ps. aeruginosa but not other respiratory pathogens had high concentrations of 2-AA in the head space of in vitro cultures when analysed by GC/MS. 2-AA was stable for 6 hours in deactivated glass sampling bulbs but was not stable in Tedlar® bags. Optimisation of GC/MS allowed detection levels of 2-AA to low pico mol/mol range in breath. The 2-AA was detected in a significantly higher proportion of subjects colonised with Ps. aeruginosa 15/16 (93.7%) than both the healthy controls 5/17 (29%) (p < 0.0002) and CF patients not colonised with Ps. aeruginosa 4/13(30.7%) (p < 0.001). The sensitivity and specificity of the 2-AA breath test compared to isolation of Ps. aeruginosa in sputum and/or BALF was 93.8% (95% CI, 67-99) and 69.2% (95% CI, 38-89) respectively. The peak integration values for 2-AA analysis in the breath samples were significantly higher in Ps. aeruginosa colonised subjects (median 242, range 0-1243) than the healthy controls (median 0, range 0-161; p < 0.001) and CF subjects not colonised with Ps. aeruginosa (median 0, range 0-287; p < 0.003) Conclusions Our results report 2-AA as a promising breath biomarker for the detection of Ps. aeruginosa infections in the cystic fibrosis lung. PMID:21054900

  14. Cut-off optimization for 13C-urea breath test in a community-based trial by mathematic, histology and serology approach.

    PubMed

    Li, Zhe-Xuan; Huang, Lei-Lei; Liu, Cong; Formichella, Luca; Zhang, Yang; Wang, Yu-Mei; Zhang, Lian; Ma, Jun-Ling; Liu, Wei-Dong; Ulm, Kurt; Wang, Jian-Xi; Zhang, Lei; Bajbouj, Monther; Li, Ming; Vieth, Michael; Quante, Michael; Zhou, Tong; Wang, Le-Hua; Suchanek, Stepan; Soutschek, Erwin; Schmid, Roland; Classen, Meinhard; You, Wei-Cheng; Gerhard, Markus; Pan, Kai-Feng

    2017-05-18

    The performance of diagnostic tests in intervention trials of Helicobacter pylori (H.pylori) eradication is crucial, since even minor inaccuracies can have major impact. To determine the cut-off point for 13 C-urea breath test ( 13 C-UBT) and to assess if it can be further optimized by serologic testing, mathematic modeling, histopathology and serologic validation were applied. A finite mixture model (FMM) was developed in 21,857 subjects, and an independent validation by modified Giemsa staining was conducted in 300 selected subjects. H.pylori status was determined using recomLine H.pylori assay in 2,113 subjects with a borderline 13 C-UBT results. The delta over baseline-value (DOB) of 3.8 was an optimal cut-off point by a FMM in modelling dataset, which was further validated as the most appropriate cut-off point by Giemsa staining (sensitivity = 94.53%, specificity = 92.93%). In the borderline population, 1,468 subjects were determined as H.pylori positive by recomLine (69.5%). A significant correlation between the number of positive H.pylori serum responses and DOB value was found (r s  = 0.217, P < 0.001). A mathematical approach such as FMM might be an alternative measure in optimizing the cut-off point for 13 C-UBT in community-based studies, and a second method to determine H.pylori status for subjects with borderline value of 13 C-UBT was necessary and recommended.

  15. The Diagnostic Validity of the 13C-Urea Breath Test in the Gastrectomized Patients: Single Tertiary Center Retrospective Cohort Study

    PubMed Central

    Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho

    2014-01-01

    Background: This study was conducted to evaluate the diagnostic validity of the 13C-urea breath test (13C-UBT) in the remnant stomach after partial gastrectomy for gastric cancer. Methods: The 13C-UBT results after Helicobacter pylori eradication therapy was compared with the results of endoscopic biopsy-based methods in the patients who have received partial gastrectomy for the gastric cancer. Results: Among the gastrectomized patients who showed the positive 13C-UBT results (≥ 2.5‰, n = 47) and negative 13C-UBT results (< 2.5‰, n = 114) after H. pylori eradication, 26 patients (16.1%) and 4 patients (2.5%) were found to show false positive and false negative results based on biopsy-based methods, respectively. The sensitivity, specificity, false positive rate, and false negative rate for the cut-off value of 2.5‰ were 84.0%, 80.9%, 19.1%, and 16.0%, respectively. The positive and negative predictive values were 44.7% and 96.5%, respectively. In the multivariate analysis, two or more H. pylori eradication therapies (odds ratio = 3.248, 95% confidence interval= 1.088–9.695, P = 0.035) was associated with a false positive result of the 13C-UBT. Conclusions: After partial gastrectomy, a discordant result was shown in the positive 13C-UBT results compared to the endoscopic biopsy methods for confirming the H. pylori status after eradication. Additional endoscopic biopsy-based H. pylori tests would be helpful to avoid unnecessary treatment for H. pylori eradication in these cases. PMID:25574466

  16. Positive or negative fructose breath test results do not predict response to fructose restricted diet in children with recurrent abdominal pain: results from a prospective randomized trial.

    PubMed

    Wirth, S; Klodt, C; Wintermeyer, P; Berrang, J; Hensel, K; Langer, T; Heusch, A

    2014-09-01

    To perform a prospective, blinded, randomized interventional trial in patients with recurrent abdominal pain. The primary endpoint was to determine the abdominal pain intensity after 2 weeks of fructose restricted diet. Secondary endpoints were changes of pain frequency and a secondary symptom score (SSS). 103 individuals with recurrent abdominal pain for more than 3 months were randomized. 51 patients were allocated to group A (diet) and 52 to group B (no diet). 2 weeks later the patients underwent hydrogen breath test and were assigned to the test positive or negative group to identify patients with fructose malabsorption. 2 weeks after intervention the pain score decreased significantly from a median 5.5 in group A to 4 and did not change significantly in group B (5.3 to 5). In group A both patients with positive and negative breath tests had a significant lower pain score (-2 and -1.75, respectively). Frequency of abdominal pain decreased in both groups but without significant difference, SSS improved only in group A from median 6 to 3.5. Positive breath test was no predicting factor, neither was abdominal pain during the test. Fructose restricted diet in children and adolescents with recurrent abdominal pain may be of benefit to improve both abdominal pain symptoms and other secondary symptoms. Since a negative breath test result does not exclude a positive response to fructose restriction, the hydrogen breath test does not seem to be the appropriate diagnostic mean to predict the response to the diet. © Georg Thieme Verlag KG Stuttgart · New York.

  17. The likelihood of acetone interference in breath alcohol measurement

    DOT National Transportation Integrated Search

    1985-09-01

    This report discusses the significance of possible interference of acetone in breath alcohol testing. The following dimensions were considered: 1) what levels of acetone concentration may appear on the breath; 2) what levels of acetone concentration ...

  18. Spontaneous breathing test in the prediction of extubation failure in the pediatric population.

    PubMed

    Nascimento, Milena Siciliano; Rebello, Celso Moura; Vale, Luciana Assis Pires Andrade; Santos, Érica; Prado, Cristiane do

    2017-01-01

    To assess whether the spontaneous breathing test can predict the extubation failure in pediatric population. A prospective and observational study that evaluated data of inpatients at the Pediatric Intensive Care Unit between May 2011 and August 2013, receiving mechanical ventilation for at least 24 hours followed by extubation. The patients were classified in two groups: Test Group, with patients extubated after spontaneous breathing test, and Control Group, with patients extubated without spontaneous breathing test. A total of 95 children were enrolled in the study, 71 in the Test Group and 24 in the Control Group. A direct comparison was made between the two groups regarding sex, age, mechanical ventilation time, indication to start mechanical ventilation and respiratory parameters before extubation in the Control Group, and before the spontaneous breathing test in the Test Group. There was no difference between the parameters evaluated. According to the analysis of probability of extubation failure between the two groups, the likelihood of extubation failure in the Control Group was 1,412 higher than in the Test Group, nevertheless, this range did not reach significance (p=0.706). This model was considered well-adjusted according to the Hosmer-Lemeshow test (p=0.758). The spontaneous breathing test was not able to predict the extubation failure in pediatric population. Avaliar se o teste de respiração espontânea pode ser utilizado para predizer falha da extubação na população pediátrica. Estudo prospectivo, observacional, no qual foram avaliados todos os pacientes internados no Centro de Terapia Intensiva Pediátrica, no período de maio de 2011 a agosto de 2013, que utilizaram ventilação mecânica por mais de 24 horas e que foram extubados. Os pacientes foram classificados em dois grupos: Grupo Teste, que incluiu os pacientes extubados depois do teste de respiração espontânea; e Grupo Controle, pacientes foram sem teste de respiração espont

  19. Impact of Breathing 100% Oxygen on Radiation-Induced Cognitive Impairment

    PubMed Central

    Wheeler, Kenneth T.; Payne, Valerie; D’Agostino, Ralph B.; Walb, Matthew C.; Munley, Michael T.; Metheny-Barlow, Linda J.; Robbins, Mike E.

    2015-01-01

    Future space missions are expected to include increased extravehicular activities (EVAs) during which astronauts are exposed to high-energy space radiation while breathing 100% oxygen. Given that brain irradiation can lead to cognitive impairment, and that oxygen is a potent radiosensitizer, there is a concern that astronauts may be at greater risk of developing cognitive impairment when exposed to space radiation while breathing 100% O2 during an EVA. To address this concern, unanesthetized, unrestrained, young adult male Fischer 344 × Brown Norway rats were allowed to breathe 100% O2 for 30 min prior to, during and 2 h after whole-body irradiation with 0, 1, 3, 5 or 7 Gy doses of 18 MV X rays delivered from a medical linear accelerator at a dose rate of ~425 mGy/min. Irradiated and unirradiated rats breathing air (~21% O2) served as controls. Cognitive function was assessed 9 months postirradiation using the perirhinal cortex-dependent novel object recognition task. Cognitive function was not impaired until the rats breathing either air or 100% O2 received a whole-body dose of 7 Gy. However, at all doses, cognitive function of the irradiated rats breathing 100% O2 was improved over that of the irradiated rats breathing air. These data suggest that astronauts are not at greater risk of developing cognitive impairment when exposed to space radiation while breathing 100% O2 during an EVA. PMID:25338095

  20. 13C-Labeled-Starch Breath Test in Congenital Sucrase-isomaltase Deficiency.

    PubMed

    Robayo-Torres, Claudia C; Diaz-Sotomayor, Marisela; Hamaker, Bruce R; Baker, Susan S; Chumpitazi, Bruno P; Opekun, Antone R; Nichols, Buford L

    2018-06-01

    Human starch digestion is a multienzyme process involving 6 different enzymes: salivary and pancreatic α-amylase; sucrase and isomaltase (from sucrose-isomaltase [SI]), and maltase and glucoamylase (from maltase-glucoamylase [MGAM]). Together these enzymes cleave starch to smaller molecules ultimately resulting in the absorbable monosaccharide glucose. Approximately 80% of all mucosal maltase activity is accounted for by SI and the reminder by MGAM. Clinical studies suggest that starch may be poorly digested in those with congenital sucrase-isomaltase deficiency (CSID). Poor starch digestion occurs in individuals with CSID and can be documented using a noninvasive C-breath test (BT). C-Labled starch was used as a test BT substrate in children with CSID. Sucrase deficiency was previously documented in study subjects by both duodenal biopsy enzyme assays and C-sucrose BT. Breath CO2 was quantitated at intervals before and after serial C-substrate loads (glucose followed 75 minutes later by starch). Variations in metabolism were normalized against C-glucose BT (coefficient of glucose absorption). Control subjects consisted of healthy family members and a group of children with functional abdominal pain with biopsy-proven sucrase sufficiency. Children with CSID had a significant reduction of C-starch digestion mirroring that of their duodenal sucrase and maltase activity and C-sucrase BT. In children with CSID, starch digestion may be impaired. In children with CSID, starch digestion correlates well with measures of sucrase activity.

  1. Studies regarding the mechanism of false negative urea breath tests with proton pump inhibitors.

    PubMed

    Graham, David Y; Opekun, Antone R; Hammoud, Fadi; Yamaoka, Yoshio; Reddy, Rita; Osato, Michael S; El-Zimaity, Hala M T

    2003-05-01

    The mechanism of false negative urea breath tests (UBTs) results among proton pump inhibitor (PPI) users is unknown. We studied the time course of PPI-associated negative UBT, the relation to Helicobacter pylori density, and whether gastric acidification would prevent false negative UBT results. In the UBT experiment, H. pylori-infected volunteers received omeprazole 20 mg b.i.d. for 13.5 days. UBTs with citric acid were done before, after 6.5 days of PPI, and 1, 2, 4, 7, and 14 days after therapy. In the culture and histology experiment, after a wash-out of >5 months, nine of the original subjects were rechallenged with omeprazole for 6.5 days. Antral and corpus biopsies for histology and culture were done before and 1 day after PPI administration. Thirty subjects (mean age 42 yr) were enrolled. UBTs were significantly reduced on day 6.5 (p = 0.031); 10 subjects (33%) developed transient negative UBTs. The UBT recovered in all but one subject by the fourth day post-PPI and in all subjects by day 14. In the culture and histology experiment, upon PPI rechallenge, three of nine subjects (33%) had negative UBTs. H. pylori density, whether measured by culture or histology, decreased with PPI therapy; antral biopsies became histologically negative in five subjects and corpus biopsies in three subjects. PPI-induced negative UBT results were related to the anti-H. pylori effect of the PPI. Acidification of the stomach did not prevent false negative UBT results. Three days is likely the minimum delay from stopping PPI until one should perform a test for active infection. A delay of 14 days is preferred.

  2. The effects of corticotrophin-releasing factor and two antagonists on breathing movements in fetal sheep.

    PubMed Central

    Bennet, L; Johnston, B M; Vale, W W; Gluckman, P D

    1990-01-01

    1. The respiratory effects of corticotrophin-releasing factor (CRF) and the CRF antagonists alpha-helical CRF 9-41 (alpha hCRF) and [DPhe 12, Nle 21-38] rCRF (12-41) (DPhe CRF) have been studied in unanaesthetized fetal lambs of 125-140 days gestation. 2. CRF when given as a 10 micrograms bolus followed by a 5 micrograms h-1 infusion into a lateral cerebral ventricle caused prolonged continuous fetal breathing movements which were stimulated in both amplitude and frequency but which did not persist during hypoxia. 3. Lower doses of CRF (20 ng bolus followed by 10 ng h-1) increased the amplitude but not the frequency of fetal breathing movements which did not become continuous. 4. At higher doses (20 micrograms bolus followed by 10-15 micrograms h-1) CRF induced cerebral convulsions which were also associated with fetal breathing movements of increased amplitude and frequency. 5. The CRF antagonists alpha hCRF and DPhe CRF both inhibited fetal breathing movements and induced a prolonged apnoea which was resistant to the stimulatory effects of 5-6% hypercapnia. 6. We conclude that CRF stimulates breathing movements in the fetal lamb. The finding that administration of the CRF antagonists alone cause apnoea suggests that CRF may have a tonic role in the regulation of fetal breathing movements. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:2348387

  3. A comparison of diagnostic tests for lactose malabsorption - which one is the best?

    PubMed Central

    2009-01-01

    Background Perceived milk intolerance is a common complaint, and tests for lactose malabsorption (LM) are unreliable. This study assesses the agreement between diagnostic tests for LM and describes the diagnostic properties of the tests. Methods Patients above 18 years of age with suspected LM were included. After oral intake of 25 g lactose, a combined test with measurement of serum glucose (s-glucose) and hydrogen (H2) and methane (CH4) in expired air was performed and symptoms were recorded. In patients with discrepancies between the results, the combined test was repeated and a gene test for lactose non-persistence was added. The diagnosis of LM was based on an evaluation of all tests. The following tests were compared: Increase in H2, CH4, H2+CH4 and H2+CH4x2 in expired air, increase in s-glucose, and symptoms. The agreement was calculated and the diagnostic properties described. Results Sixty patients were included, seven (12%) had LM. The agreement (kappa-values) between the methods varied from 0.25 to 0.91. The best test was the lactose breath test with measurement of the increase in H2 + CH4x2 in expired air. With a cut-off level < 18 ppm, the area under the ROC-curve was 0.967 and sensitivity was 100%. This shows that measurement of CH4 in addition to H2 improves the diagnostic properties of the breath test. Conclusion The agreement between commonly used methods for the diagnosis of LM was unsatisfactory. A lactose breath test with measurement of H2 + CH4x2 in expired air had the best diagnostic properties. PMID:19878587

  4. Small intestinal malabsorption in chronic alcoholism: a retrospective study of alcoholic patients by the ¹⁴C-D-xylose breath test.

    PubMed

    Hope, Håvar; Skar, Viggo; Sandstad, Olav; Husebye, Einar; Medhus, Asle W

    2012-04-01

    The ¹⁴C-D-xylose breath test was used at Ullevål University Hospital in the period from 1986 TO 1995 for malabsorption testing. The objective of this retrospective study was to reveal whether patients with chronic alcoholism may have intestinal malabsorption. The consecutive ¹⁴C-D-xylose breath test database was reviewed and patients with the diagnosis of chronic alcoholism were identified. ¹⁴C-D-xylose breath test results of the alcoholic patients were compared with the results of untreated celiac patients and patient and healthy controls. In the ¹⁴C-D-xylose breath test, ¹⁴C-D-xylose was dissolved in water and given orally after overnight fast. Breath samples were taken at 30-min intervals for 210 min, and ¹⁴CO₂ : ¹²CO₂ ratios were calculated for each time point, presenting a time curve for ¹⁴C-D-xylose absorption. Urine was collected after 210 min and the fraction of the total d-xylose passed was calculated (U%). ¹⁴CO₂ in breath and ¹⁴C-D-xylose in urine were analyzed using liquid scintillation. Both breath and urine analysis revealed a pattern of malabsorption in alcoholics comparable with untreated celiac patients, with significantly reduced absorption of d-xylose compared with patient and healthy controls. Alcoholic patients have a significantly reduced ¹⁴C-D-xylose absorption, comparable with untreated celiac patients. This indicates a reduced intestinal function in chronic alcoholism.

  5. Adaptive Servoventilation (ASV) in Patients with Sleep Disordered Breathing Associated with Chronic Opioid Medications for Non-Malignant Pain

    PubMed Central

    Farney, Robert J.; Walker, James M.; Boyle, Kathleen M.; Cloward, Tom V.; Shilling, Kevin C.

    2008-01-01

    Background: Adaptive servoventilation (ASV) can be effective therapy for specific types of central apnea such as Cheyne-Stokes respiration (CSR). Patients treated chronically with opioids develop central apneas and ataxic breathing patterns (Biot's respiration), but therapy with CPAP is usually unsuccessful. There are no published studies of ASV in patients with sleep apnea complicated by chronic opioid therapy. Methods: Retrospective analysis of 22 consecutive patients referred for evaluation and treatment of sleep apnea who had been using opioid medications for at least 6 months, had an apnea-hypopnea index (AHI) >20/h, and had been tested with ASV. Baseline polysomnography was compared with CPAP and ASV. Outcome variables: AHI, central apnea index (CAI), obstructive apnea index (OAI), hypopnea index (HI), desaturation index, mean SpO2, lowest SpO2, time SpO2 <90%, and degree of Biot's respiration. Results: Mean (SD) AHI measured 66.6/h (37.3) at baseline, 70.1/h (32.6) on CPAP, and 54.2/h (33.0) on ASV. With ASV, the mean OAI was significantly decreased to 2.4/h (p < 0.0001), and the mean HI increased significantly to 35.7/h (p < 0.0001). The decrease of CAI from 26.4/h to 15.6/h was not significant (p = 0.127). Biot's breathing persisted, and oxygenation parameters were unimproved with ASV. Conclusions: Due to residual respiratory events and hypoxemia, ASV was considered insufficient therapy in these patients. Persistence of obstructive events could be due to suboptimal pressure settings (end expiratory and/or maximal inspiratory). Residual central events could be related to fundamental differences in the pathophysiology of CSR compared to opioid induced breathing disturbances. Citation: Farney RJ; Walker JM; Boyle KM; Cloward TV; Shilling KC. Adaptive servoventilation (ASV) in patients with sleep disordered breathing associated with chronic opioid medications for non-malignant pain. J Clin Sleep Med 2008;4(4):311-319. PMID:18763421

  6. Breathing metabolic simulator.

    NASA Technical Reports Server (NTRS)

    Bartlett, R. G., Jr.; Hendricks, C. M.; Morison, W. B.

    1971-01-01

    Description of a device for simulation of the human breathing and metabolic parameters required for the evaluation of respiratory diagnostic, monitoring, support and resuscitation equipment. The remotely controlled device allows wide variations in breathing rate and depth, breath velocity contour, oxygen uptake and carbon dioxide release to simulate conditions from sleep to hard work, with respiration exchange ratios ranging from hypoventilation to hyperventilation. It also reduces the cost of prolonged testing when simulation chambers with human subjects require three shifts of crews and standby physicians. Several block diagrams of the device and subsystems are given.

  7. Breath condenser coatings affect measurement of biomarkers in exhaled breath condensate.

    PubMed

    Rosias, P P; Robroeks, C M; Niemarkt, H J; Kester, A D; Vernooy, J H; Suykerbuyk, J; Teunissen, J; Heynens, J; Hendriks, H J; Jöbsis, Q; Dompeling, E

    2006-11-01

    Exhaled breath condensate collection is not yet standardised and biomarker measurements are often close to lower detection limits. In the current study, it was hypothesised that adhesive properties of different condenser coatings interfere with measurements of eicosanoids and proteins in breath condensate. In vitro, condensate was derived from a collection model using two test solutions (8-isoprostane and albumin) and five condenser coatings (silicone, glass, aluminium, polypropylene and Teflon). In vivo, condensate was collected using these five coatings and the EcoScreen condenser to measure 8-isoprostane, and three coatings (silicone, glass, EcoScreen) to measure albumin. In vitro, silicone and glass coatings had significantly higher albumin recovery compared with the other coatings. A similar trend was observed for 8-isoprostane recovery. In vivo, median (interquartile range) 8-isoprostane concentrations were significantly higher using silicone (9.2 (18.8) pg.mL(-1)) or glass (3.0 (4.5) pg.mL(-1)) coating, compared with aluminium (0.5 (2.4) pg.mL(-1)), polypropylene (0.5 (0.5) pg.mL(-1)), Teflon (0.5 (0.0) pg.mL(-1)), and EcoScreen (0.5 (2.0) pg.mL(-1)). Albumin in vivo was mainly detectable using glass coating. In conclusion, a condenser with silicone or glass coating is more efficient for measurement of 8-isoprostane or albumin in exhaled breath condensate, than EcoScreen, aluminium, polypropylene or Teflon. Guidelines for exhaled breath condensate standardisation should include the most valid condenser coating to measure a specific biomarker.

  8. Correlations between the circadian patterns of body temperature, metabolism and breathing in rats.

    PubMed

    Mortola, Jacopo P

    2007-02-15

    It had been demonstrated previously that the circadian patterns of activity and state of arousal are not essential for the manifestation of the daily patterns of pulmonary ventilation (V(E)), tidal volume (V(T)) and breathing frequency (f). In this study we investigated the extent of the linkage between the circadian pattern of breathing and those of body temperature (T(b)) and metabolic rate (oxygen consumption, V(O2), and carbon dioxide production, V(CO2)). Rats were instrumented for measurements of T(b) (by telemetry), and placed in a chamber for continuous 13-day period of measurement of breathing (by a modification of the barometric methodology), and of V(O2) and V(CO2) (by an open flow method). After the first 4 days in control conditions under a 12 h light:12 h dark (L:D) cycle, a perturbation was introduced on day 4, with an L-phase prolongation of 12 h, and on day 9, with an D-phase prolongation of 12 h. During the control days 1-4, all variables had daily oscillations (higher values in D), in phase with each other. During the perturbations (days 4-13), changes in T(b), V(O2) and V(CO2), averaged over the whole period, correlated significantly better with f than with V(T). Day-by-day X-Y loops indicated that V (E), V(T) and f could lead significantly the changes of T(b), V(O2) and V(CO2), and that these relations changed throughout the perturbation period. In addition, f and V(T) did not change necessarily in phase with each other. It is concluded that neither the oscillation in T(b) nor that in metabolism can be considered the direct cause of the daily oscillation of breathing. Presumably, the circadian pattern of breathing reflects the interplay of the daily patterns of many variables, none acting as the primary guide of the breathing daily rhythm.

  9. 13C-sodium acetate breath test for evaluation of gastric emptying times in dogs with gastric dilatation-volvulus.

    PubMed

    Schmitz, S; Jansen, N; Failing, K; Neiger, R

    2013-01-01

    The aim of the study was to assess solid phase gastric emptying via non-invasive 13C-sodium acetate breath test in large breed dogs with or without gastric dilatation-volvulus (GDV). Dogs were recruited into one of the following groups: group 1 = healthy large breed dogs with no history of GDV, group 2 = dogs that underwent elective abdominal surgery for reasons unrelated to the gastrointestinal tract, and group 3 = dogs that underwent laparotomy and gastropexy to correct GDV. The dogs were fed a test meal containing 100 mg 13C-sodium acetate (for group 2 and 3, this was < 48 hours post-operatively). Breath samples were obtained at baseline and every 30 minutes for 3 hours, then every hour for a total of 7 hours. 12CO2/13CO2 ratio was measured for each breath sample via non-dispersive infrared spectroscopy and 25%, 50% and 75% gastric emptying times were calculated and compared between groups. Gastric emptying times were significantly prolonged in dogs undergoing surgery (group 2) compared to group 1 and 3. Also, gastric emptying times of dogs with GDV were significantly prolonged compared to controls, but not to the same extent as dogs in group 2. There was a significant effect of abdominal surgery on gastric emptying times. Surprisingly, dogs after GDV surgery and gastropexy had shorter gastric emptying times than dogs undergoing laparotomy for reasons other than GDV, but still prolonged compared to healthy controls. The reason for these differences requires further study.

  10. Inward contaminant leakage tests of the S-Tron Corporation emergency escape breathing device.

    DOT National Transportation Integrated Search

    1992-04-01

    At the request of S-Tron Corporation, to support their contract with the U.S. Navy, performance tests of the Emergency Escape Breathing Device (EEBD) were conducted in the Environmental Physiology Research Section contaminant leakage chamber. Sulfur ...

  11. Control of gill ventilation and air-breathing in the bowfin amia calva

    PubMed

    Hedrick; Jones

    1999-01-01

    The purpose of this study was to investigate the roles of branchial and gas bladder reflex pathways in the control of gill ventilation and air-breathing in the bowfin Amia calva. We have previously determined that bowfin use two distinct air-breathing mechanisms to ventilate the gas bladder: type I air breaths are characterized by exhalation followed by inhalation, are stimulated by aquatic or aerial hypoxia and appear to regulate O2 gas exchange; type II air breaths are characterized by inhalation alone and possibly regulate gas bladder volume and buoyancy. In the present study, we test the hypotheses (1) that gill ventilation and type I air breaths are controlled by O2-sensitive chemoreceptors located in the branchial region, and (2) that type II air breaths are controlled by gas bladder mechanosensitive stretch receptors. Hypothesis 1 was tested by examining the effects of partial or complete branchial denervation of cranial nerves IX and X to the gill arches on gill ventilation frequency (fg) and the proportion of type I air breaths during normoxia and hypoxia; hypothesis II was tested by gas bladder inflation and deflation. Following complete bilateral branchial denervation, fg did not differ from that of sham-operated control fish; in addition, fg was not significantly affected by aquatic hypoxia in sham-operated or denervated fish. In sham-operated fish, aquatic hypoxia significantly increased overall air-breathing frequency (fab) and the percentage of type I breaths. In fish with complete IX-X branchial denervation, fab was also significantly increased during aquatic hypoxia, but there were equal percentages of type I and type II air breaths. Branchial denervation did not affect the frequency of type I air breaths during aquatic hypoxia. Gas bladder deflation via an indwelling catheter resulted in type II breaths almost exclusively; furthermore, fab was significantly correlated with the volume removed from the gas bladder, suggesting a volume

  12. Individuality of breathing during volitional moderate hyperventilation.

    PubMed

    Besleaga, Tudor; Blum, Michaël; Briot, Raphaël; Vovc, Victor; Moldovanu, Ion; Calabrese, Pascale

    2016-01-01

    The aim of this study is to investigate the individuality of airflow shapes during volitional hyperventilation. Ventilation was recorded on 18 healthy subjects following two protocols: (1) spontaneous breathing (SP1) followed by a volitional hyperventilation at each subject's spontaneous (HVSP) breathing rate, (2) spontaneous breathing (SP2) followed by hyperventilation at 20/min (HV20). HVSP and HV20 were performed at the same level of hypocapnia: end tidal CO2 (FETCO2) was maintained at 1% below the spontaneous level. At each breath, the tidal volume (VT), the breath (TTOT), the inspiratory (TI) and expiratory durations, the minute ventilation, VT/TI, TI/TTOT and the airflow shape were quantified by harmonic analysis. Under different conditions of breathing, we test if the airflow profiles of the same individual are more similar than airflow profiles between individuals. Minute ventilation was not significantly different between SP1 (6.71 ± 1.64 l·min(-1)) and SP2 (6.57 ± 1.31 l·min(-1)) nor between HVSP (15.88 ± 4.92 l·min(-1)) and HV20 (15.87 ± 4.16 l·min(-1)). Similar results were obtained for FETCO2 between SP1 (5.06 ± 0.54 %) and SP2 (5.00 ± 0.51%), and HVSP (4.07 ± 0.51%) and HV20 (3.88 ± 0.42%). Only TI/TTOT remained unchanged in all four conditions. Airflow shapes were similar when comparing SP1-SP2, HVSP-HV20, and SP1-HVSP but not similar when comparing SP2-HV20. These results suggest the existence of an individuality of airflow shape during volitional hyperventilation. We conclude that volitional ventilation alike automatic breathing follows inherent properties of the ventilatory system. Registered by Pascale Calabrese on ClinicalTrials.gov, # NCT01881945.

  13. The 50Ah NiH2 cell life test results

    NASA Technical Reports Server (NTRS)

    Jamin, Thierry; Puig, Olivier

    1992-01-01

    Information is given in viewgraph form for the 50 AhNiH2 cell life test results. Information is given on pressure vessel design, electrochemical/stack design, cell electrical characteristics, and cell life test results.

  14. Imaging Breathing Rate in the CO2Absorption Band.

    PubMed

    Fei, Jin; Zhu, Zhen; Pavlidis, Ioannis

    2005-01-01

    Following up on our previous work, we have developed one more non-contact method to measure human breathing rate. We have retrofitted our Mid-Wave Infra-Red (MWIR) imaging system with a narrow band-pass filter in the CO2absorption band (4.3 µm). This improves the contrast between the foreground (i.e., expired air) and background (e.g., wall). Based on the radiation information within the breath flow region, we get the mean dynamic thermal signal. This signal is quasi-periodic due to the interleaving of high and low intensities corresponding to expirations and inspirations respectively. We sample the signal at a constant rate and then determine the breathing frequency through Fourier analysis. We have performed experiments on 9 subjects at distances ranging from 6-8 ft. We compared the breathing rate computed by our novel method with ground-truth measurements obtained via a traditional contact device (PowerLab/4SP from ADInstruments with an abdominal transducer). The results show high correlation between the two modalities. For the first time, we report a Fourier based breathing rate computation method on a MWIR signal in the CO2absorption band. The method opens the way for desktop, unobtrusive monitoring of an important vital sign, that is, breathing rate. It may find widespread applications in preventive medicine as well as sustained physiological monitoring of subjects suffering from chronic ailments.

  15. Air sampling unit for breath analyzers

    NASA Astrophysics Data System (ADS)

    Szabra, Dariusz; Prokopiuk, Artur; Mikołajczyk, Janusz; Ligor, Tomasz; Buszewski, Bogusław; Bielecki, Zbigniew

    2017-11-01

    The paper presents a portable breath sampling unit (BSU) for human breath analyzers. The developed unit can be used to probe air from the upper airway and alveolar for clinical and science studies. The BSU is able to operate as a patient interface device for most types of breath analyzers. Its main task is to separate and to collect the selected phases of the exhaled air. To monitor the so-called I, II, or III phase and to identify the airflow from the upper and lower parts of the human respiratory system, the unit performs measurements of the exhaled CO2 (ECO2) in the concentration range of 0%-20% (0-150 mm Hg). It can work in both on-line and off-line modes according to American Thoracic Society/European Respiratory Society standards. A Tedlar bag with a volume of 5 dm3 is mounted as a BSU sample container. This volume allows us to collect ca. 1-25 selected breath phases. At the user panel, each step of the unit operation is visualized by LED indicators. This helps us to regulate the natural breathing cycle of the patient. There is also an operator's panel to ensure monitoring and configuration setup of the unit parameters. The operation of the breath sampling unit was preliminarily verified using the gas chromatography/mass spectrometry (GC/MS) laboratory setup. At this setup, volatile organic compounds were extracted by solid phase microextraction. The tests were performed by the comparison of GC/MS signals from both exhaled nitric oxide and isoprene analyses for three breath phases. The functionality of the unit was proven because there was an observed increase in the signal level in the case of the III phase (approximately 40%). The described work made it possible to construct a prototype of a very efficient breath sampling unit dedicated to breath sample analyzers.

  16. A comparison between lactose breath test and quick test on duodenal biopsies for diagnosing lactase deficiency in patients with self-reported lactose intolerance.

    PubMed

    Furnari, Manuele; Bonfanti, Daria; Parodi, Andrea; Franzè, Jolanda; Savarino, Edoardo; Bruzzone, Luca; Moscatelli, Alessandro; Di Mario, Francesco; Dulbecco, Pietro; Savarino, Vincenzo

    2013-02-01

    A lactose breath test (LBT) is usually used to diagnose lactase deficiency, and a lactose quick test (LQT) has been proposed as a new test on duodenal biopsies to detect this disorder. We aimed to assess the diagnostic accuracy of LBT and LQT and their ability to predict the clinical response to a lactose-free diet in patients with self-reported lactose intolerance. Fifty-five patients (age 47 ± 14 y; M/F 15/36) underwent upper gastrointestinal endoscopy and 25g-LBT. Two duodenal biopsies were taken to determine lactase deficiency (normal, mild, or severe) by LQT and to rule out other causes of secondary lactose malabsorption. Patients with a positive LBT and normal LQT also underwent a glucose breath test to exclude small intestinal bacterial overgrowth as a cause of the former result. The severity of gastrointestinal symptoms was measured with a GSS questionnaire, under basal condition and 1 month after a lactose-free diet. Lactose malabsorption was detected in 31/51 patients with LBT and in 37/51 patients with LQT (P = NS). Celiac disease was found in 2 patients. Two LBT+ patients showed a positive glucose breath test for small intestinal bacterial overgrowth. Eight patients had a mild hypolactasia by LQT and a negative LBT, but they had a significant improvement of symptoms after diet. LQT and LBT were concordant in 83% of cases and predicted the response to a lactose-free diet in 98% and 81% of the cases, respectively (P = 0.03). LQT is as sensitive as LBT in detecting lactase deficiency; however, it seems to be more accurate than LBT in predicting the clinical response to a lactose-free diet.

  17. Coaxial Tubing Systems Increase Artificial Airway Resistance and Work of Breathing.

    PubMed

    Wenzel, Christin; Schumann, Stefan; Spaeth, Johannes

    2017-09-01

    Tubing systems are an essential component of the ventilation circuit, connecting the ventilator to the patient's airways. Coaxial tubing systems incorporate the inspiratory tube within the lumen of the expiratory one. We hypothesized that by design, these tubing systems increase resistance to air flow compared with conventional ones. We investigated the flow-dependent pressure gradient across coaxial, conventional disposable, and conventional reusable tubing systems from 3 different manufacturers. Additionally, the additional work of breathing and perception of resistance during breathing through the different devices were determined in 18 healthy volunteers. The pressure gradient across coaxial tubing systems was up to 6 times higher compared with conventional ones (1.90 ± 0.03 cm H 2 O vs 0.34 ± 0.01 cm H 2 O, P < .001) and was higher during expiration compared with inspiration ( P < .001). Additional work of breathing and perceived breathing resistance were highest in coaxial tubing systems, accordingly. Our findings suggest that the use of coaxial tubing systems should be carefully considered with respect to their increased resistance. Copyright © 2017 by Daedalus Enterprises.

  18. Space Station Freedom NiH2 cell testing program

    NASA Technical Reports Server (NTRS)

    Moore, Bruce; Frate, Dave

    1994-01-01

    Testing for the Space Station Freedom Nickel Hydrogen Cell Test Program began in 1990 at Crave Division, Naval Surface Warfare Center. The program has included receipt inspection, random vibration, acceptance, characterization, and life cycle testing of Ni-H2 cells in accordance with the NASA LeRC Interagency Order C-31001-J. A total of 400 Ni-H2 cells have been received at NAVSURFWARCENDIV Crane from three separate manufacturers; Yardney Technical Products (Yardney), Eagle Picher Industries (Eagle Picher), and Gates Energy Products (Gates). Of those, 308 cells distributed among 39 packs have undergone life cycle testing under a test regime simulating low earth orbit conditions. As of 30 September 1993, there are 252 cells assembled into 32 packs still on life cycle test. Since the beginning of the program, failed cells have been detected in all phases of testing. The failures include the following; seven 65 AmpHr and 81 AmpHr Yardney cells were found to be leaking KOH on receipt, one 65 AmpHr Eagle Picher cell failed the acceptance test, one 65 AmpHr Gates cell failed during the characterization test, and six 65 AmpHr Gates cells failed the random vibration test. Of the 39 life cycle packs, testing on seven packs, 56 cells, has been suspended because of low end of discharge voltages. All of the failed life cycle packs were cycled at 60% depth of discharge.

  19. Single-breath CO2 analysis as a predictor of lung volume in a healthy animal model during controlled ventilation.

    PubMed

    Stenz, R I; Grenier, B; Thompson, J E; Arnold, J H

    1998-08-01

    To examine the utility of single-breath CO2 analysis as a measure of lung volume. A prospective, animal cohort study comparing 21 parameters derived from single-breath CO2 analysis with lung volume measurements determined by nitrogen washout in animals during controlled ventilation. An animal laboratory in a university-affiliated medical center. Seven healthy lambs. The single-breath CO2 analysis station consists of a mainstream capnometer, a variable orifice pneumotachometer, a signal processor and computer software with capability for both on- and off-line data analysis. Twenty-one derived components of the CO2 expirogram were evaluated as predictors of lung volume. Lung volume was manipulated by 3 cm H2O incremental increases in positive end-expiratory pressure from 0 to 21 cm H2O, and ranged between 147 and 942 mL. Fifty-five measurements of lung volume were available for comparison with derived variables from the CO2 expirogam. Stepwise linear regression identified four variables that were most predictive of lung volume: a) dynamic lung compliance; b) the slope of phase 3; c) the slope of phase 2 divided by the mixed expired CO2 tension; and d) airway deadspace. The multivariate equation was highly statistically significant and explained 94% of the variance (adjusted r2 =.94, p < .0001). The bias and precision of the calculated lung volume was .00 and 51, respectively. The mean percent difference for the lung volume estimate derived from the single-breath CO2 analysis station was 0.79%. Our data indicate that analysis of the CO2 expirogram can yield accurate information about lung volume. Specifically, four variables derived from a plot of expired CO2 concentration vs. expired volume predict changes in lung volume in healthy lambs with an adjusted coefficient of determination of .94. Prospective application of this technology in the setting of lung injury and rapidly changing physiology is essential in determining the clinical usefulness of the technique.

  20. H2/O2 three-body rates at high temperatures

    NASA Technical Reports Server (NTRS)

    Marinelli, William J.; Kessler, William J.; Piper, Lawrence G.; Rawlins, W. Terry

    1990-01-01

    The extraction of thrust from air breathing hypersonic propulsion systems is critically dependent on the degree to which chemical equilibrium is reached in the combustion process. In the combustion of H2/Air mixtures, slow three-body chemical reactions involving H-atoms, O-atoms, and the OH radical play an important role in energy extraction. A first-generation high temperature and pressure flash-photolysis/laser-induced fluorescence reactor was designed and constructed to measure these important three-body rates. The system employs a high power excimer laser to produce these radicals via the photolysis of stable precursors. A novel two-photon laser-induced fluorescence technique is employed to detect H-atoms without optical thickness or O2 absorption problems. To demonstrate the feasibility of the technique the apparatus in the program is designed to perform preliminary measurements on the H + O2 + M reaction at temperatures from 300 to 835 K.

  1. 13C-Breath Tests for Sucrose Digestion in Congenital Sucrase Isomaltase Deficient and Sacrosidase Supplemented Patients

    PubMed Central

    Robayo-Torres, Claudia C.; Opekun, Antone R.; Quezada-Calvillo, Roberto; Xavier, Villa; Smith, E. O’Brian; Navarrete, Marilyn; Baker, S. Susan; Nichols, Buford L

    2008-01-01

    Congenital sucrase-isomaltase deficiency (CSID) is characterized by absence or deficiency of the mucosal sucrase-isomaltase enzyme. Specific diagnosis requires upper gastrointestinal biopsy with evidence of low to absent sucrase enzyme activity and normal histology. The hydrogen breath test (BT) is useful but is not specific for confirmation of CSID. We investigated a more specific 13C-sucrose labeled BT. Objectives were to determine if CSID can be detected with the 13C-sucrose BT without duodenal biopsy sucrase assay and if the 13C-sucrose BT can document restoration of sucrose digestion by CSID patients after oral supplementation with sacrosidase (Sucraid®). Methods Ten CSID patients were diagnosed by low biopsy sucrase activity. Ten controls were children who underwent endoscopy and biopsy because of dyspepsia or chronic diarrhea with normal mucosal enzymes activity and histology. Uniformly-labeled 13C-glucose and 13C-sucrose loads were orally administered. 13CO2 breath enrichments were assayed using an infrared spectrophotometer. In CSID patients the 13C-sucrose load was repeated adding Sucraid®. Sucrose digestion and oxidation were calculated as a mean % coefficient of glucose oxidation (% CGO) averaged between 30 and 90 minutes. Results Classification of patients by 13C-sucrose BT % CGO agreed with biopsy sucrase activity. The breath test also documented the return to normal of sucrose digestion and oxidation after supplementation of CSID patients with Sucraid®. Conclusion 13C-sucrose BT is an accurate and specific non-invasive confirmatory test for CSID and for enzyme replacement management. PMID:19330928

  2. [Evaluation of benefits of the course of positive pressure breathing training on exercise performance].

    PubMed

    Medvedev, D V; Gorbaneva, E P; Iumatova, S N; Kuznetsova, T Iu; Solopov, I N; Katuntsev, V P

    2007-01-01

    The purpose was to evaluate effects of muscle training combined with positive pressure breathing on exercise performance of 16 runners at the age of 18-20. All subjects had the first or second-class sport qualification. The 4-wk. training course for the experimental group (n=11) included 20-25% of exercises performed in an aperture mask creating an inspiration-expiration resistance of 8-10 mm H2O. The control group (n=5) worked on the same training course but w/o positive pressure breathing. The course began and ended with the PWC170 test in order to evaluate exercise performance. Indices of external respiration and gas exchange were determined on metabolograph Ergooxyscreen (Jaeger) and lung-tester Spirosift-3000 (Fukuda). Inspiration and expiration force of the breathing muscles (mm Hg) was measured isometrically with the help of a pneumomanometer. Heart rate was calculated from ECG R-R intervals. It was stated that positive pressure breathing during muscle training increases significantly sportsmen's exercise performance due to growth of the body spare capacities, and optimization of the body systems dependence structure and efficiency.

  3. Clinical utility of breath ammonia for evaluation of ammonia physiology in healthy and cirrhotic adults

    PubMed Central

    Spacek, Lisa A; Mudalel, Matthew; Tittel, Frank; Risby, Terence H; Solga, Steven F

    2016-01-01

    Blood ammonia is routinely used in clinical settings to assess systemic ammonia in hepatic encephalopathy and urea cycle disorders. Despite its drawbacks, blood measurement is often used as a comparator in breath studies because it is a standard clinical test. We sought to evaluate sources of measurement error and potential clinical utility of breath ammonia compared to blood ammonia. We measured breath ammonia in real time by quartz enhanced photoacoustic spectrometry and blood ammonia in 10 healthy and 10 cirrhotic participants. Each participant contributed 5 breath samples and blood for ammonia measurement within 1 h. We calculated the coefficient of variation (CV) for 5 breath ammonia values, reported medians of healthy and cirrhotic participants, and used scatterplots to display breath and blood ammonia. For healthy participants, mean age was 22 years (±4), 70% were men, and body mass index (BMI) was 27 (±5). For cirrhotic participants, mean age was 61 years (±8), 60% were men, and BMI was 31 (±7). Median blood ammonia for healthy participants was within normal range, 10 μmol L−1 (interquartile range (IQR), 3–18) versus 46 μmol L−1 (IQR, 23–66) for cirrhotic participants. Median breath ammonia was 379 pmol mL−1 CO2 (IQR, 265–765) for healthy versus 350 pmol mL−1 CO2 (IQR, 180–1013) for cirrhotic participants. CV was 17 ± 6%. There remains an important unmet need in the evaluation of systemic ammonia, and breath measurement continues to demonstrate promise to fulfill this need. Given the many differences between breath and blood ammonia measurement, we examined biological explanations for our findings in healthy and cirrhotic participants. We conclude that based upon these preliminary data breath may offer clinically important information this is not provided by blood ammonia. PMID:26658550

  4. Acid-sensing ion channels contribute to chemosensitivity of breathing-related neurons of the nucleus of the solitary tract.

    PubMed

    Huda, Rafiq; Pollema-Mays, Sarah L; Chang, Zheng; Alheid, George F; McCrimmon, Donald R; Martina, Marco

    2012-10-01

    Cellular mechanisms of central pH chemosensitivity remain largely unknown. The nucleus of the solitary tract (NTS) integrates peripheral afferents with central pathways controlling breathing; NTS neurons function as central chemosensors, but only limited information exists concerning the ionic mechanisms involved. Acid-sensing ion channels (ASICs) mediate chemosensitivity in nociceptive terminals, where pH values ∼6.5 are not uncommon in inflammation, but are also abundantly expressed throughout the brain where pHi s tightly regulated and their role is less clear. Here we test the hypothesis that ASICs are expressed in NTS neurons and contribute to intrinsic chemosensitivity and control of breathing. In electrophysiological recordings from acute rat NTS slices, ∼40% of NTS neurons responded to physiological acidification (pH 7.0) with a transient depolarization. This response was also present in dissociated neurons suggesting an intrinsic mechanism. In voltage clamp recordings in slices, a pH drop from 7.4 to 7.0 induced ASIC-like inward currents (blocked by 100 μM amiloride) in ∼40% of NTS neurons, while at pH ≤ 6.5 these currents were detected in all neurons tested; RT-PCR revealed expression of ASIC1 and, less abundantly, ASIC2 in the NTS. Anatomical analysis of dye-filled neurons showed that ASIC-dependent chemosensitive cells (cells responding to pH 7.0) cluster dorsally in the NTS. Using in vivo retrograde labelling from the ventral respiratory column, 90% (9/10) of the labelled neurons showed an ASIC-like response to pH 7.0, suggesting that ASIC currents contribute to control of breathing. Accordingly, amiloride injection into the NTS reduced phrenic nerve activity of anaesthetized rats with an elevated arterial P(CO(2)) .

  5. Air-breathing aerospace plane development essential: Hypersonic propulsion flight tests

    NASA Technical Reports Server (NTRS)

    Mehta, Unmeel B.

    1994-01-01

    Hypersonic air-breathing propulsion utilizing scramjets can fundamentally change transatmospheric accelerators for low earth-to-orbit and return transportation. The value and limitations of ground tests, of flight tests, and of computations are presented, and scramjet development requirements are discussed. It is proposed that near full-scale hypersonic propulsion flight tests are essential for developing a prototype hypersonic propulsion system and for developing computational-design technology so that it can be used for designing this system. In order to determine how these objectives should be achieved, some lessons learned from past programs are presented. A conceptual two-stage-to-orbit (TSTO) prototype/experimental aerospace plane is recommended as a means of providing access-to-space and for conducting flight tests. A road map for achieving these objectives is also presented.

  6. Comparison of breath testing with fructose and high fructose corn syrups in health and IBS

    PubMed Central

    Skoog, S. M.; Bharucha, A. E.; Zinsmeister, A. R.

    2008-01-01

    Although incomplete fructose absorption has been implicated to cause gastrointestinal symptoms, foods containing high fructose corn syrup (HFCS) contain glucose. Glucose increases fructose absorption in healthy subjects. Our hypothesis was that fructose intolerance is less prevalent after HFCS consumption compared to fructose alone in healthy subjects and irritable bowel syndrome (IBS). Breath hydrogen levels and gastrointestinal symptoms were assessed after 40 g of fructose (12% solution) prepared either in water or as HFCS, administered in double-blind randomized order on 2 days in 20 healthy subjects and 30 patients with IBS. Gastrointestinal symptoms were recorded on 100-mm Visual Analogue Scales. Breath hydrogen excretion was more frequently abnormal (P < 0.01) after fructose (68%) than HFCS (26%) in controls and patients. Fructose intolerance (i.e. abnormal breath test and symptoms) was more prevalent after fructose than HFCS in healthy subjects (25% vs 0%, P = 0.002) and patients (40% vs 7%, P = 0.062). Scores for several symptoms (e.g. bloating r = 0.35) were correlated (P ≤ 0.01) to peak breath hydrogen excretion after fructose but not HFCS; in the fructose group, this association did not differ between healthy subjects and patients. Symptoms were not significantly different after fructose compared to HFCS. Fructose intolerance is more prevalent with fructose alone than with HFCS in health and in IBS. The prevalence of fructose intolerance is not significantly different between health and IBS. Current methods for identifying fructose intolerance should be modified to more closely reproduce fructose ingestion in daily life. PMID:18221251

  7. Comparison of breath testing with fructose and high fructose corn syrups in health and IBS.

    PubMed

    Skoog, S M; Bharucha, A E; Zinsmeister, A R

    2008-05-01

    Although incomplete fructose absorption has been implicated to cause gastrointestinal symptoms, foods containing high fructose corn syrup (HFCS) contain glucose. Glucose increases fructose absorption in healthy subjects. Our hypothesis was that fructose intolerance is less prevalent after HFCS consumption compared to fructose alone in healthy subjects and irritable bowel syndrome (IBS). Breath hydrogen levels and gastrointestinal symptoms were assessed after 40 g of fructose (12% solution) prepared either in water or as HFCS, administered in double-blind randomized order on 2 days in 20 healthy subjects and 30 patients with IBS. Gastrointestinal symptoms were recorded on 100-mm Visual Analogue Scales. Breath hydrogen excretion was more frequently abnormal (P < 0.01) after fructose (68%) than HFCS (26%) in controls and patients. Fructose intolerance (i.e. abnormal breath test and symptoms) was more prevalent after fructose than HFCS in healthy subjects (25% vs. 0%, P = 0.002) and patients (40% vs. 7%, P = 0.062). Scores for several symptoms (e.g. bloating r = 0.35) were correlated (P < or = 0.01) to peak breath hydrogen excretion after fructose but not HFCS; in the fructose group, this association did not differ between healthy subjects and patients. Symptoms were not significantly different after fructose compared to HFCS. Fructose intolerance is more prevalent with fructose alone than with HFCS in health and in IBS. The prevalence of fructose intolerance is not significantly different between health and IBS. Current methods for identifying fructose intolerance should be modified to more closely reproduce fructose ingestion in daily life.

  8. [Likeness between respiratory responses on CO2 in conditions of natural breathing and voluntary-controlled mechanical ventilation].

    PubMed

    Pogodin, M A; Granstrem, M P; Dimitrienko, A I

    2007-04-01

    We did Read CO2 rebreathing tests in 8 adult males. Both at natural breathing, and at self-controlled mechanical ventilation, volunteers increased ventilation proportionally to growth end-tidal PCO2. Inside individual distinctions of responses to CO2 during controlled mechanical ventilation are result of the voluntary motor control.

  9. High capacity for extracellular acid-base regulation in the air-breathing fish Pangasianodon hypophthalmus.

    PubMed

    Damsgaard, Christian; Gam, Le Thi Hong; Tuong, Dang Diem; Thinh, Phan Vinh; Huong Thanh, Do Thi; Wang, Tobias; Bayley, Mark

    2015-05-01

    The evolution of accessory air-breathing structures is typically associated with reduction of the gills, although branchial ion transport remains pivotal for acid-base and ion regulation. Therefore, air-breathing fishes are believed to have a low capacity for extracellular pH regulation during a respiratory acidosis. In the present study, we investigated acid-base regulation during hypercapnia in the air-breathing fish Pangasianodon hypophthalmus in normoxic and hypoxic water at 28-30°C. Contrary to previous studies, we show that this air-breathing fish has a pronounced ability to regulate extracellular pH (pHe) during hypercapnia, with complete metabolic compensation of pHe within 72 h of exposure to hypoxic hypercapnia with CO2 levels above 34 mmHg. The high capacity for pHe regulation relies on a pronounced ability to increase levels of HCO3(-) in the plasma. Our study illustrates the diversity in the physiology of air-breathing fishes, such that generalizations across phylogenies may be difficult. © 2015. Published by The Company of Biologists Ltd.

  10. Solubility testing of actinides on breathing-zone and area air samples

    NASA Astrophysics Data System (ADS)

    Metzger, Robert Lawrence

    The solubility of inhaled radionuclides in the human lung is an important characteristic of the compounds needed to perform internal dosimetry assessments for exposed workers. A solubility testing method for uranium and several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALSsp°ler ) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of Usb3Osb8. This makes it possible to characterize solubility profiles in every section of operating facilities where airborne nuclides are found using common breathing zone air samples. The new method was evaluated by analyzing uranium compounds from two uranium mills whose product had been previously analyzed by in vitro solubility testing in the laboratory and in vivo solubility testing in rodents. The new technique compared well with the in vivo rodent solubility profiles. The method was then used to evaluate the solubility profiles in all process sections of an operating in situ uranium plant using breathing zone and area air samples collected during routine

  11. Breathing exercises for dysfunctional breathing/hyperventilation syndrome in adults.

    PubMed

    Jones, Mandy; Harvey, Alex; Marston, Louise; O'Connell, Neil E

    2013-05-31

    Dysfunctional breathing/hyperventilation syndrome (DB/HVS) is a respiratory disorder, psychologically or physiologically based, involving breathing too deeply and/or too rapidly (hyperventilation) or erratic breathing interspersed with breath-holding or sighing (DB). DB/HVS can result in significant patient morbidity and an array of symptoms including breathlessness, chest tightness, dizziness, tremor and paraesthesia. DB/HVS has an estimated prevalence of 9.5% in the general adult population, however, there is little consensus regarding the most effective management of this patient group. (1) To determine whether breathing exercises in patients with DB/HVS have beneficial effects as measured by quality of life indices (2) To determine whether there are any adverse effects of breathing exercises in patients with DB/HVS SEARCH METHODS: We identified trials for consideration using both electronic and manual search strategies. We searched CENTRAL, MEDLINE, EMBASE, and four other databases. The latest search was in February 2013. We planned to include randomised, quasi-randomised or cluster randomised controlled trials (RCTs) in which breathing exercises, or a combined intervention including breathing exercises as a key component, were compared with either no treatment or another therapy that did not include breathing exercises in patients with DB/HVS. Observational studies, case studies and studies utilising a cross-over design were not eligible for inclusion.We considered any type of breathing exercise for inclusion in this review, such as breathing control, diaphragmatic breathing, yoga breathing, Buteyko breathing, biofeedback-guided breathing modification, yawn/sigh suppression. Programs where exercises were either supervised or unsupervised were eligible as were relaxation techniques and acute-episode management, as long as it was clear that breathing exercises were a key component of the intervention.We excluded any intervention without breathing exercises or

  12. Carbon Monoxide in Exhaled Breath Testing and Therapeutics

    PubMed Central

    Ryter, Stefan W.; Choi, Augustine M.K.

    2013-01-01

    Carbon monoxide (CO), a low molecular weight gas, is a ubiquitous environmental product of organic combustion, which is also produced endogenously in the body, as the byproduct of heme metabolism. CO binds to hemoglobin, resulting in decreased oxygen delivery to bodily tissues at toxicological concentrations. At physiological concentrations, CO may have endogenous roles as a potential signaling mediator in vascular function and cellular homeostasis. Exhaled CO (eCO), similar to exhaled nitric oxide (eNO), has been evaluated as a candidate breath biomarker of pathophysiological states, including smoking status, and inflammatory diseases of the lung and other organs. eCO values have been evaluated as potential indicators of inflammation in asthma, stable COPD and exacerbations, cystic fibrosis, lung cancer, or during surgery or critical care. The utility of eCO as a marker of inflammation, and potential diagnostic value remains incompletely characterized. Among other candidate “medicinal gases” with therapeutic potential, (e.g., NO and H2S), CO has been shown to act as an effective anti-inflammatory agent in preclinical animal models of inflammatory disease, acute lung injury, sepsis, ischemia/reperfusion injury and organ graft rejection. Current and future clinical trials will evaluate the clinical applicability of this gas as a biomarker and/or therapeutic in human disease. PMID:23446063

  13. Carbon-14 urea breath test for the diagnosis of Campylobacter pylori associated gastritis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, B.J.; Surveyor, I.

    1988-01-01

    Urease in the human gastric mucosa is a marker for infection with Campylobacter pylori (CP), an organism suspected of causing chronic gastritis and peptic ulceration. To detect gastric urease, we examined 32 patients who were being evaluated for possible peptic ulcer disease. Fasting patients were given 10 microCi (370 kBq) of /sup 14/C-labeled urea. Breath samples were collected in hyamine at intervals between 1 and 30 min. The amount of /sup 14/C collected at these times was expressed as: body weight X (% of administered dose of /sup 14/C in sample)/(mmol of CO/sub 2/ collected). The presence of C. pylorimore » colonization was also determined by examination of multiple endoscopic gastric biopsy specimens. On average, patients who were proven to have C. pylori infection exhaled 20 times more labeled CO/sub 2/ than patients who were not infected. The difference between infected patients and C. pylori negative control patients was highly significant at all time points between 2 and 30 min after ingestion of the radionuclide (p less than 0.0001). The noninvasive urea breath is less expensive than endoscopic biopsy of the stomach and more accurate than serology as a means of detecting Campylobacter pylori infection. Because the test detects actual viable CP organisms, it can be used to confirm eradication of the bacterium after antibacterial therapy.« less

  14. Effects of Breathing Resistance on Resting Ventilatory Sensitivity to CO2

    DTIC Science & Technology

    2014-08-12

    be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE...elements were designed to generate work of breathing per tidal volume of 1 kPa when minute ventilation was 100 L/min. Resistance caused no systematic...the laboratory is considerably lower and that end- tidal PCO2 is higher with resistance in the breathing circuit than without it.2, 3 Work has

  15. Elimination characteristics of post-operative isoflurane levels in alveolar exhaled breath via PTR-MS analysis.

    PubMed

    Fernández Del Río, R; O'Hara, M E; Pemberton, P; Whitehouse, T; Mayhew, C A

    2016-10-12

    Isoflurane (1-chloro-2,2,2-trifluoroethyl difluoromethyl ether), C 3 H 2 ClF 5 O, is a commonly used inhalation anaesthetic. Using a proton transfer reaction mass spectrometer (PTR-MS) we have detected isoflurane in the breath of patients several weeks following major surgery. That isoflurane is detected in the breath of patients so long after being anaesthetised raises questions about when cognitive function has fully returned to a patient. Temporal profiles of isoflurane concentrations in breath are presented for five patients (F/M 3/2, mean age 50 years, min-max 36-58 years) who had undergone liver transplant surgery. In addition, results from a headspace analysis of isoflurane are presented so that the product ions resulting from the reactions of H 3 O + with isoflurane in PTR-MS could be easily identified in the absence of the complex chemical environment of breath. Six product ions were identified. In order of increasing m/z (using the 35 Cl isotope where appropriate) these are [Formula: see text] (m/z 51), CHFCl + (m/z 67), CF 3 CHCl + (m/z 117), C 3 F 4 OCl + (m/z 163), C 3 H 2 F 4 OCl + (m/z 165), and C 3 F 4 OCl + H 2 O (m/z 183). No protonated parent was detected. For the headspace study both clean air and CO 2 enriched clean air (4% CO 2 ) were used as buffer gases in the drift tube of the PTR-MS. The CO 2 enriched air was used to determine if exhaled breath would affect the product ion branching ratios. Importantly no significant differences were observed, and therefore for isoflurane the product ion distributions determined in a normal air mixture can be used for breath analysis. Given that PTR-MS can be operated under different reduced electric fields (E/N), the dependence of the product ion branching percentages for isoflurane on E/N (96-138 Td) are reported.

  16. Walk test and school performance in mouth-breathing children.

    PubMed

    Boas, Ana Paula Dias Vilas; Marson, Fernando Augusto de Lima; Ribeiro, Maria Angela Gonçalves de Oliveira; Sakano, Eulália; Conti, Patricia Blau Margosian; Toro, Adyléia Dalbo Contrera; Ribeiro, José Dirceu

    2013-01-01

    In recent decades, many studies on mouth breathing (MB) have been published; however, little is known about many aspects of this syndrome, including severity, impact on physical and academic performances. Compare the physical performance in a six minutes walk test (6MWT) and the academic performance of MB and nasal-breathing (NB) children and adolescents. This is a descriptive, cross-sectional, and prospective study with MB and NB children submitted to the 6MWT and scholar performance assessment. We included 156 children, 87 girls (60 NB and 27 MB) and 69 boys (44 NB and 25 MB). Variables were analyzed during the 6MWT: heart rate (HR), respiratory rate, oxygen saturation, distance walked in six minutes and modified Borg scale. All the variables studied were statistically different between groups NB and MB, with the exception of school performance and HR in 6MWT. MB affects physical performance and not the academic performance, we noticed a changed pattern in the 6MWT in the MB group. Since the MBs in our study were classified as non-severe, other studies comparing the academic performance variables and 6MWT are needed to better understand the process of physical and academic performances in MB children.

  17. Effect of influenza vaccination on oxidative stress products in breath.

    PubMed

    Phillips, Michael; Cataneo, Renee N; Chaturvedi, Anirudh; Danaher, Patrick J; Devadiga, Anantrai; Legendre, David A; Nail, Kim L; Schmitt, Peter; Wai, James

    2010-06-01

    Viral infections cause increased oxidative stress, so a breath test for oxidative stress biomarkers (alkanes and alkane derivatives) might provide a new tool for early diagnosis. We studied 33 normal healthy human subjects receiving scheduled treatment with live attenuated influenza vaccine (LAIV). Each subject was his or her own control, since they were studied on day 0 prior to vaccination, and then on days 2, 7 and 14 following vaccination. Breath volatile organic compounds (VOCs) were collected with a breath collection apparatus, then analyzed by automated thermal desorption with gas chromatography and mass spectroscopy. A Monte Carlo simulation technique identified non-random VOC biomarkers of infection based on their C-statistic values (area under curve of receiver operating characteristic). Treatment with LAIV was followed by non-random changes in the abundance of breath VOCs. 2, 8-Dimethyl-undecane and other alkane derivatives were observed on all days. Conservative multivariate models identified vaccinated subjects on day 2 (C-statistic = 0.82, sensitivity = 63.6% and specificity = 88.5%); day 7 (C-statistic = 0.94, sensitivity = 88.5% and specificity = 92.3%); and day 14 (C-statistic = 0.95, sensitivity = 92.3% and specificity = 92.3%). The altered breath VOCs were not detected in live attenuated influenza vaccine, excluding artifactual contamination. LAIV vaccination in healthy humans elicited a prompt and sustained increase in breath biomarkers of oxidative stress. A breath test for these VOCs could potentially identify humans who are acutely infected with influenza, but who have not yet developed clinical symptoms or signs of disease.

  18. Laser detection of CO2 concentration in human breath at various diseases

    NASA Astrophysics Data System (ADS)

    Ageev, Boris G.; Nikiforova, Olga Y.

    2015-12-01

    Absorption spectra of human breath in 10 μm region were recorded by the use of intracavity laser photo-acoustic gas analyzer based on tunable waveguide CO2 laser. Healthy persons and patients with various diseases were studied. For determination of CO2 concentration in exhalation samples gas analyzer was calibrated by reference gaseous mixture CO2-N2. It was obtained that CO2 concentration values in human breath of healthy persons are greater than that of patients with various diseases.

  19. [pH values in the pharynx of the patients presenting with compromised nasal breathing of inflammatory and non-inflammatory genesis concomitant with gastroesophageal reflux disease].

    PubMed

    Subbotina, M V; Temnikova, I V; Onuchina, E V

    2015-01-01

    The objective of the present study was to estimate the influence of gastroesophageal reflux disease (GERD) on the pH values in the pharynx and nose. It included 87 patients at the age varying from 18 to 81 years admitted to the Irkutsk-based Railway Clinical Hospital and allocated to four groups. Group 1 was comprised of 25 patients presenting with gastroesophageal reflux disease and chronic rhinosinusitis (CRS), group 2 consisted of 29 patients with CRS in the absence of GERD, group 3 included 22 patients with nasal septum deformations (NSD) and GERD, group 4 included 11 patients with NSD and motor rhinitis without GERD. The control group was formed from 10 volunteers. pH was measured by the contact method with the use ofEkokhim indicator paper. Gastroesophageal reflux disease was diagnosed following the recommendations of the Montreal consensus. It was shown that pH values in the pharynx of the patients with compromised nasal breathing of any origin in combination with GERD were lower than in the absence of GERD and in the healthy volunteers. The study groups did not differ in terms of pH values in the nasal cavity. It is concluded that pH values 4 or lower may serve as the criterion for pharyngo-laryngeal reflux (PLR) concomitant with HERD while pH 5 occurs more frequently in the patients with compromised nasal breathing of any etiology, regardless of the presence or absence of GERD.Disordered nasal breathing of any genesis in the patients presenting with gastroesophageal reflux disease was associated with the feeling of the lump in the throat, congestion of the respiratory tract and the nose, pain in the ears, cardialgia, and irregular heartbeat. It isrecommended to use pH measurements as a criterion for diagnostics of pharyngo-laryngeal reflux in the patients presenting with gastroesophageal reflux disease.

  20. Right recumbent position on gastric emptying of water evidenced by 13C breath testing

    PubMed Central

    Sanaka, Masaki; Urita, Yoshihisa; Yamamoto, Takatsugu; Shirai, Tsuguru; Kimura, Satoshi; Aoyagi, Hitoshi; Kuyama, Yasushi

    2013-01-01

    AIM: To compare the impact of the right recumbent position with the sitting position on gastric emptying of water. METHODS: In eight healthy male volunteers, the 13C acetate breath test was performed twice to assess gastric emptying of 100 mL tap water. Subjects were seated in one test and lying on their right side in the other. In both positions, pulmonary 13CO2 exhalation curves were obtained by plotting breath data against time. Percent gastric retention curves were created by analyzing data using the Wagner-Nelson protocol. RESULTS: No significant posture effect was found in pulmonary 13CO2 output curves (P = 0.2150), whereas a significant effect was seen in gastric retention curves (P = 0.0315). The percent retention values at 10 min and 15 min were significantly smaller when subjects were in the right recumbent position compared with the seated position (P < 0.05). Our results verified the accelerating effect of the right recumbent position on gastric emptying of non-nutritive solutions. Concerning clinical implications, this study suggests that placing patients with acute pain on their right side after oral administration of analgesic drugs in solution is justified as an effective practice for rapid pain relief. For patients with gastrointestinal reflux symptoms, sleeping in the right recumbent position may reduce nocturnal symptoms, as delayed gastric emptying can cause reflux symptoms. CONCLUSION: Gastric emptying of water occurs more quickly when a subject lies on the right side compared with sitting. PMID:23372358

  1. [Breath alcohol test in construction sites in the Province of Belluno: a campaign in favour of health promotion and surveillance and against drinking].

    PubMed

    Marcolina, Daniela; De Marzo, Nicoletta; Riccio, Maria Teresa

    2011-01-01

    Health impairment due to alcohol use and abuse is well known, in terms of relationship with traffic accidents and work accidents. In Italy almost 10 per cent of accidents at work involve intoxicated people injuring themselves and innocent victims. Alcohol abuse is a factor involved in determining severe accidents in the construction industry and epidemiological studies demonstrated a relationship between an elevated alcohol use and severity of accidents. Since in the Province of Belluno alcohol consumption may be elevated also at work, the two Occupational Health Units (SPISAL) in the province organized a campaign of information and surveillance against alcohol consumption at work in the construction industry. This report shows the campaign results, mainly in terms of breath alcohol tests performed in construction workers. After an extensive information campaign we inspected 50 sites, where 105 construction companies were at work, and tested 294 workers by breath alcohol test. No-one refused the test. Only 2.7% construction workers were positive for the breath alcohol test, and the levels were not elevated. This study shows that the construction workers in Belluno Province are responsible drinkers and are well aware of the policy of prohibition of alcohol consumption at work.

  2. Exhaled breath temperature in children: reproducibility and influencing factors.

    PubMed

    Vermeulen, S; Barreto, M; La Penna, F; Prete, A; Martella, S; Biagiarelli, F; Villa, M P

    2014-09-01

    This study will investigate the reproducibility and influencing factors of exhaled breath temperature measured with the tidal breathing technique in asthmatic patients and healthy children. Exhaled breath temperature, fractional exhaled nitric oxide, and spirometry were assessed in 124 children (63 healthy and 61 asthmatic), aged 11.2 ± 2.5 year, M/F 73/51. A modified version of the American Thoracic Society questionnaire on the child's present and past respiratory history was obtained from parents. Parents were also asked to provide detailed information on their child's medication use during the previous 4 weeks. Ear temperature, ambient temperature, and relative-ambient humidity were also recorded. Exhaled breath temperature measurements were highly reproducible; the second measurement was higher than the first measurement, consistent with a test-retest situation. In 13 subjects, between-session within-day reproducibility of exhaled breath temperature was still high. Exhaled breath temperature increased with age and relative-ambient humidity. Exhaled breath temperature was comparable in healthy and asthmatic children; when adjusted for potential confounders (i.e. ambient conditions and subject characteristics), thermal values of asthmatic patients exceeded those of the healthy children by 1.1 °C. Normalized exhaled breath temperature, by subtracting ambient temperature, was lower in asthmatic patients treated with inhaled corticosteroids than in those who were corticosteroid-naive. Measurements of exhaled breath temperature are highly reproducible, yet influenced by several factors. Corrected values, i.e. normalized exhaled breath temperature, could help us to assess the effect of therapy with inhaled corticosteroids. More studies are needed to improve the usefulness of the exhaled breath temperature measured with the tidal breathing technique in children.

  3. Breath holding spell

    MedlinePlus

    ... such as Riley-Day syndrome or Rett syndrome Iron deficiency anemia A family history of breath holding spells ( ... tests may be done to check for an iron deficiency. Other tests that may be done include: EKG ...

  4. The Diagnostic Validity of Citric Acid-Free, High Dose (13)C-Urea Breath Test After Helicobacter pylori Eradication in Korea.

    PubMed

    Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Hwang, Jae Jin; Lee, Hyun Joo; Lee, AeRa; Jeong, Yeon Sang; Oh, Sooyeon; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho

    2015-06-01

    The (13)C-urea breath test ((13)C-UBT) is a noninvasive method for diagnosing Helicobacter pylori (H. pylori) infection. The aims of this study were to evaluate the diagnostic validity of the (13)C-UBT cutoff value and to identify influencing clinical factors responsible for aberrant results. (13)C-UBT (UBiTkit; Otsuka Pharmaceutical, cutoff value: 2.5‰) results in the range 2.0‰ to 10.0‰ after H. pylori eradication therapy were compared with the results of endoscopic biopsy results of the antrum and body. Factors considered to affect test results adversely were analyzed. Among patients with a positive (13)C-UBT result (2.5‰ to 10.0‰, n = 223) or a negative (13)C-UBT result (2.0‰ to < 2.5‰, n = 66) after H. pylori eradication, 73 patients (34.0%) were false positive, and one (1.5%) was false negative as determined by endoscopic biopsy. The sensitivity, specificity, false-positive rate, and false-negative rate for a cutoff value of 2.5‰ were 99.3%, 47.1%, 52.9%, and 0.7%, respectively, and positive and negative predictive values of the (13)C-UBT were 67.3% and 98.5%, respectively. Multivariate analysis showed that a history of two or more previous H. pylori eradication therapies (OR = 2.455, 95%CI = 1.299-4.641) and moderate to severe gastric intestinal metaplasia (OR = 3.359, 95%CI = 1.572-7.178) were associated with a false-positive (13)C-UBT result. The (13)C-UBT cutoff value currently used has poor specificity for confirming H. pylori status after eradication, and this lack of specificity is exacerbated in patients that have undergone multiple prior eradication therapies and in patients with moderate to severe gastric intestinal metaplasia. In addition, the citric-free (13)C-UBT would increase a false-positive (13)C-UBT result. © 2015 John Wiley & Sons Ltd.

  5. 49 CFR 40.245 - What is the procedure for an alcohol screening test using a saliva ASD or a breath tube ASD?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... test using a saliva ASD or a breath tube ASD? 40.245 Section 40.245 Transportation Office of the... Alcohol Screening Tests § 40.245 What is the procedure for an alcohol screening test using a saliva ASD or a breath tube ASD? (a) As the STT or BAT, you must take the following steps when using the saliva...

  6. Progressive Changes in a Distributed Neural Circuit Underlie Breathing Abnormalities in Mice Lacking MeCP2.

    PubMed

    Huang, Teng-Wei; Kochukov, Mikhail Y; Ward, Christopher S; Merritt, Jonathan; Thomas, Kaitlin; Nguyen, Tiffani; Arenkiel, Benjamin R; Neul, Jeffrey L

    2016-05-18

    Rett syndrome (RTT) is a neurodevelopmental disorder caused by mutations in Methyl-CpG-binding protein 2 (MECP2). Severe breathing abnormalities are common in RTT and are reproduced in mouse models of RTT. Previously, we found that removing MeCP2 from the brainstem and spinal cord in mice caused early lethality and abnormal breathing. To determine whether loss of MeCP2 in functional components of the respiratory network causes specific breathing disorders, we used the Cre/LoxP system to differentially manipulate MeCP2 expression throughout the brainstem respiratory network, specifically within HoxA4-derived tissues, which include breathing control circuitry within the nucleus tractus solitarius and the caudal part of ventral respiratory column but do not include more rostral parts of the breathing control circuitry. To determine whether respiratory phenotypes manifested in animals with MeCP2 removed from specific pons medullary respiratory circuits, we performed whole-body plethysmography and electrophysiological recordings from in vitro brainstem slices from mice lacking MeCP2 in different circuits. Our results indicate that MeCP2 expression in the medullary respiratory network is sufficient for normal respiratory rhythm and preventing apnea. However, MeCP2 expression within components of the breathing circuitry rostral to the HoxA4 domain are neither sufficient to prevent the hyperventilation nor abnormal hypoxic ventilatory response. Surprisingly, we found that MeCP2 expression in the HoxA4 domain alone is critical for survival. Our study reveals that MeCP2 is differentially required in select respiratory components for different aspects of respiratory functions, and collectively for the integrity of this network functions to maintain proper respiration. Breathing abnormalities are a significant clinical feature in Rett syndrome and are robustly reproduced in the mouse models of this disease. Previous work has established that alterations in the function of Me

  7. CPAP of 4 cm H(2)O Has no short-term benefit at term in infants with BPD.

    PubMed

    Sandberg, Kenneth L; Hjalmarson, Ola

    2012-01-01

    Lung development and function is compromised at term in infants with bronchopulmonary dysplasia (BPD), characterized by reduced functional residual capacity (FRC) and impaired gas-mixing efficiency in distal airways. To determine whether continuous positive airway pressure (CPAP) improves FRC, ventilation, distal airway function, and gas exchange in spontaneously breathing infants with BPD. Twenty-one infants with BPD (median birth weight 0.72 kg (range 0.50-1.27) and median gestational age 26 weeks (range 23-28)) were studied before and after CPAP of 4 cm H(2)O was applied by a facemask system. A multiple-breath nitrogen washout method was used to assess FRC, ventilation, and gas-mixing efficiency. Moment analysis and lung clearance index was calculated from the nitrogen-decay curve for assessment of gas-mixing efficiency. Transcutaneous (Tc) PO(2)/PCO(2) was monitored during stable infant conditions before each washout test. When CPAP was raised from 0 to 4 cm H(2)O, FRC increased significantly together with a significant increase in moment ratios (M(1)/M(0) and M(2)/M(0)). Tc PO(2) decreased significantly and the breathing pattern changed, with significantly reduced respiratory rate, minute ventilation, and alveolar ventilation. There was also an increase in tidal volume and dead space. CPAP of 4 cm H(2)O applied with a facemask at term to infants with BPD did not improve ventilation, gas-mixing efficiency in distal airways, or oxygenation despite an increase in FRC. We speculate that instead of promoting recruitment of unventilated lung volumes, increasing the end-expiratory pressure in infants with BPD may lead to an overexpansion of already ventilated parts of the lung, causing further compromise of lung function. Copyright © 2012 S. Karger AG, Basel.

  8. Detection of Δ9-tetrahydrocannabinol in exhaled breath collected from cannabis users.

    PubMed

    Beck, Olof; Sandqvist, Sören; Dubbelboer, Ilse; Franck, Johan

    2011-10-01

    Exhaled breath has recently been proposed as a new possible matrix for drugs of abuse testing. A key drug is cannabis, and the present study was aimed at investigating the possibility of detecting tetrahydrocannabinol and tetrahydrocannabinol carboxylic acid in exhaled breath after cannabis smoking. Exhaled breath was sampled from 10 regular cannabis users and 8 controls by directing the exhaled breath by suction through an Empore C(18) disk. The disk was extracted with hexane/ethyl acetate, and the resulting extract was evaporated to dryness and redissolved in 100 μL hexane/ethyl acetate. A 3-μL aliquot was injected onto the LC-MS-MS system and analyzed using positive electrospray ionization and selected reaction monitoring. In samples collected 1-12 h after cannabis smoking, tetrahydrocannabinol was detected in all 10 subjects. The rate of excretion was between 9.0 and 77.3 pg/min. Identification of tetrahydrocannabinol was based on correct retention time relative to tetrahydrocannabinol-d(3) and correct product ion ratio. In three samples, peaks were observed for tetrahydrocannabinol carboxylic acid, but these did not fulfill identification criteria. Neither tetrahydrocannabinol or tetrahydrocannabinol carboxylic acid was detected in the controls. These results confirm older reports that tetrahydrocannabinol is present in exhaled breath following cannabis smoking and extend the detection time from minutes to hours. The results further support the idea that exhaled breath is a promising matrix for drugs-of-abuse testing.

  9. Air-breathing behavior, oxygen concentrations, and ROS defense in the swimbladders of two erythrinid fish, the facultative air-breathing jeju, and the non-air-breathing traira during normoxia, hypoxia and hyperoxia.

    PubMed

    Pelster, Bernd; Wood, Chris M; Jung, Ellen; Val, Adalberto L

    2018-05-01

    The jeju Hoplerythrinus unitaeniatus and the traira Hoplias malabaricus are two neighboring genera from the family of erythrinid fish, both possessing a two-chambered physostomous swimbladder. In the jeju the anterior section of the posterior bladder is highly vascularized, and the swimbladder is used for aerial respiration; the traira, in turn, is a water-breather that uses the swimbladder as a buoyancy organ and not for aerial oxygen uptake. Measurement of swimbladder oxygen partial pressure (PO 2 ) of fish kept at 26 °C in normoxic, hyperoxic (28-32 mg O 2 L - 1 ) or hypoxic (1-1.5 mg O 2 L - 1 ) water revealed constant values in traira swimbladder. Under normoxic conditions in the jeju swimbladder PO 2 was higher than in traira, and the PO 2 significantly increased under hyperoxic conditions, even in the absence of air breathing. In jeju, air-breathing activity increased significantly under hypoxic conditions. Hypoxic air-breathing activity was negatively correlated to swimbladder PO 2 , indicating that the swimbladder was intensely used for gas exchange under these conditions. In traira, the capacity of the ROS defense system, as assessed by measurement of activities of enzymes involved in ROS degradation and total glutathione (GSH + GSSG) concentration, was elevated after 4 h of hyperoxic and/or hypoxic exposure, although swimbladder PO 2 was not affected. In jeju, experiencing a higher variability in swimbladder PO 2 due to the air-breathing activity, only a reduced responsiveness of the ROS defense system to changing environmental PO 2 was detected.

  10. Breathing efficiency during inspiratory threshold loading in patients with chronic obstructive pulmonary disease.

    PubMed

    Baarends, E M; Schols, A M; Nusmeier, C M; van der Grinten, C P; Wouters, E F

    1998-05-01

    Patients with chronic obstructive pulmonary disease (COPD) demonstrate an increased oxygen cost of breathing. It is as yet unclear whether this is related to a decreased breathing efficiency. The aim of the present study was to compare breathing efficiency in 16 patients with COPD (11 men, five women) and 16 healthy elderly subjects (seven men, nine women), and to investigate a possible relationship between breathing efficiency and resting energy expenditure (REE). REE was measured using a ventilated hood system. Breathing efficiency was assessed by measuring oxygen consumption (V'O2), mean inspiratory mouth pressure (MIP) and flow during breathing at rest and subsequently during breathing against an inspiratory threshold (40% of maximal inspiratory pressure). During loaded breathing there was a significant increase in V'O2, MIP, and external work of breathing compared with unloaded breathing in both groups. As intended, ventilation did not increase significantly during the breathing efficiency test in the patients with COPD. The breathing efficiency (median, range) of the patients with COPD was similar (3.7%, 1.4-8.7%) to that of the healthy elderly subjects (3.2%, 1.7-8.3%). Breathing efficiency was not correlated with REE in either group. In the present study, in which dynamic hyperinflation was probably prevented, no difference in breathing efficiency was found between healthy elderly subjects and COPD patients when breathing against an external inspiratory threshold. Furthermore, breathing efficiency was not related to REE in both groups.

  11. Associations between self-reported sleep duration and sleeping disorder with concentrations of fasting and 2-h glucose, insulin, and glycosylated hemoglobin among adults without diagnosed diabetes.

    PubMed

    Ford, Earl S; Wheaton, Anne G; Chapman, Daniel P; Li, Chaoyang; Perry, Geraldine S; Croft, Janet B

    2014-07-01

    There is limited information from population-based investigations of the associations between sleep duration and sleep disorders and parameters of glucose homeostasis. The objective of the present study was to examine cross-sectional associations between sleep duration and sleep disordered breathing with concentrations of insulin, fasting and 2-h glucose, and HbA1c. Data from 11 815 adults aged ≥20 years without diagnosed diabetes (5002 with an oral glucose tolerance test) from the National Health and Nutrition Examination Survey 2005-2010 were used. Information about sleep duration (2005-2010) and sleep apnea and sleep-disordered breathing (2005-2008) was obtained via questionnaire. An estimated 36.0% of participants reported sleeping ≤6 h/night, 62.0% reported sleeping 7-9 h/night, and 2.0% reported sleeping ≥10 h/night. In 2005-2008, 33.0% reported snoring ≥5 nights per week, 5.9% reported they snorted, gasped, or stopped breathing ≥5 nights/week, and 4.2% reported sleep apnea. Sleep duration was significantly associated with fasting concentrations of insulin and concentrations of HbA1c only in models that did not adjust for body mass index (BMI). Concentrations of fasting and 2-h glucose were significantly associated with sleep duration in models that adjusted only for age. Snoring frequency was positively associated with concentrations of insulin and HbA1c. Frequency of snorting or stopping breathing and sleep apnea status were associated with concentrations of insulin and of HbA1c only when BMI was not accounted for. In a representative sample of US adults, concentrations of insulin and HbA1c were significantly associated with short sleep duration, possibly mediated by BMI. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.

  12. Prognostic Role of Exhaled Breath Condensate pH and Fraction Exhaled Nitric Oxide in Systemic Sclerosis Related Interstitial Lung Disease.

    PubMed

    Guillen-Del Castillo, Alfredo; Sánchez-Vidaurre, Sara; Simeón-Aznar, Carmen P; Cruz, María J; Fonollosa-Pla, Vicente; Muñoz, Xavier

    2017-03-01

    Interstitial lung disease (ILD) is one of the major causes of death in systemic sclerosis (SSc). This study investigated exhaled breath (EB) and exhaled breath condensate (EBC) biomarkers in patients with SSc and analyzed their role as a prognostic tool in SSc-related ILD. Fraction exhaled nitric oxide (FeNO) and exhaled carbon monoxide (eCO) measured in EB, together with pH, nitrite, nitrate and interleukin-6 levels measured in EBC were prospectively analyzed in 35 patients with SSc. Twelve patients had established ILD by chest high-resolution computed tomography (HRCT), and 23 patients showed no evidence of ILD. EB and EBC biomarkers were determined at inclusion, and pulmonary function tests were annually performed during 4 years of follow-up. No differences at baseline biomarkers levels were found between groups. In all patients studied, low EBC pH levels were associated with a decreased diffusing capacity for carbon monoxide (DLCO) during follow-up. Low FeNO levels were correlated with lower forced vital capacity (FVC) at baseline, 4years of follow-up and with a decrease in FVC and DLCO during monitoring. Among ILD patients, high eCO levels were correlated with lower baseline FVC. In the global cohort, a worse progression-free survival was identified in patients with EBC pH values lower than 7.88 and FeNO levels lower than 10.75ppb (Log Rank P=.03 and P<.01, respectively). EB and EBC could help to detect patients likely to present a deterioration on lung function during follow up. Copyright © 2016 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Ultraviolet spectroscopic breath analysis using hollow-optical fiber as gas cell

    NASA Astrophysics Data System (ADS)

    Iwata, T.; Katagiri, T.; Matsuura, Y.

    2017-02-01

    For breath analysis on ultraviolet absorption spectroscopy, an analysis system using a hollow optical fiber as gas cell is developed. The hollow optical fiber functions as a long path and extremely small volume gas cell. Firstly, the measurement sensitivity of the system is evaluated by using NO gas as a gas sample. The result shows that NO gas with 50 ppb concentration is measured by using a system with a laser-driven, high intensity light source and a 3-meter long, aluminum-coated hollow optical fiber. Then an absorption spectrum of breath sample is measured in the wavelength region of around 200-300 nm and from the spectrum, it is found that the main absorbing components in breath were H2O, isoprene, and O3 converted from O2 by radiation of ultraviolet light. Then the concentration of isoprene in breath is estimated by using multiple linear regression analysis.

  14. The application of chromatographic breath analysis in the search of volatile biomarkers of chronic kidney disease and coexisting type 2 diabetes mellitus.

    PubMed

    Grabowska-Polanowska, B; Skowron, M; Miarka, P; Pietrzycka, A; Śliwka, I

    2017-08-15

    Chromatographic studies on breath composition are aimed at finding volatile markers useful for medical diagnostics or in screening investigations. Studies leading to the development of screening breath tests are especially important for the diagnostics of chronic kidney disease (CKD) and type 2 diabetes mellitus (T2DM). The aim of the presented study was to confirm diagnostic usefulness of chosen volatile compounds detected in breath, which are suggested as potential biomarkers of renal dysfunction and diabetes. Breath analysis were carried out in three groups: 10 healthy volunteers, 10 patients with CKD and 10 patients with CKD and T2DM. All exhaled air samples were analyzed using gas chromatograph (Agilent 6890GC) coupled with mass spectrometer (5975MSD). Thermal desorption was applied as the enrichment method. TMA was detected only in CKD patients. Higher breath concentrations of methanethiol (MeSH) were observed in CKD patients with coexisting diabetes than in patients with renal dysfunction only or in the healthy group. There was a tendency of increasing MeSH concentration in breath with increasing total glutathione in plasma (r=0.53, p=0.0026). Also, a trend of increasing dimethylsulfide (DMS) levels detected in breath was noticed with an increase of hydrogen sulfide concentration in plasma (r=0.74; p=0.00001) as well as with aspartate aminotransferase (AST), (r=0.61; p=0.001). The presented results suggest the possibility of applying TMA, MeSH, and DMS detection in breath as diagnostic methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Assessment of antibacterial effect of garlic in patients infected with Helicobacter pylori using urease breath test

    PubMed Central

    Zardast, Mahmoud; Namakin, Kokab; Esmaelian Kaho, Jamil; Hashemi, Sarira Sadat

    2016-01-01

    Objective: Helicobacter pylori (H. pylori) is the most common pathogenic bacteria in the stomach. The aim of the current study was to explore the effect of oral garlic administration on bacterial urease activity inside the stomach and its contribution to the treatment of H. pylori infection. Materials and Methods: In this clinical trial, 15 patients were studied quantitatively with Urease Breath Test (UBT). The patients with gastrointestinal symptoms and a positive serum H. pylori IgG were enrolled. UBT was performed for each patient in three sessions as follows: at the beginning of the study, an initial UBT was performed based on which, the positive cases entered the study and the negative ones were excluded. Second UBT was done three days later in patients who were not receiving any treatment and were considered as the control, whereas the third UBT was performed three days after prescribing two medium-sized cloves of garlic (3 g) with their meal, twice a day (at noon and in the evening). The collected data were analyzed using ANOVA and Bonferroni tests and the significance level was set at p<0.05. Results: the mean UBT significantly differed before and after treatment with garlic cloves, being significantly lower after garlic consumption. No meaningful difference was observed in the mean UBT without garlic consumption between the first and second steps. Conclusion: Raw garlic has anti-bacterial effects against H. pylori residing in the stomach and may be prescribed along with routine drugs for the treatment of gastric H. pylori infection. PMID:27761418

  16. A study of characteristics of a reliable and practical breath alcohol screening test. Part A

    DOT National Transportation Integrated Search

    1975-08-01

    The objectives of this study were (1) to investigate several commercially available breath-alcohol screening test devices of the length-of-stain type, under standardized laboratory conditions, with respect to their ability satisfactorily to detect an...

  17. Measurement of hepatic functional mass by means of 13C-methacetin and 13C-phenylalanine breath tests in chronic liver disease: Comparison with Child-Pugh score and serum bile acid levels

    PubMed Central

    Festi, D.; Capodicasa, S.; Sandri, L.; Colaiocco-Ferrante, L.; Staniscia, T.; Vitacolonna, E.; Vestito, A.; Simoni, P.; Mazzella, G.; Portincasa, P.; Roda, E.; Colecchia, A.

    2005-01-01

    AIM: To evaluate and compare the clinical usefulness of 13C-phenylalanine and 13C-methacetin breath tests in quantitating functional hepatic mass in patients with chronic liver disease and to further compare these results with those of conventional tests, Child-Pugh score and serum bile acid levels. METHODS: One hundred and forty patients (50 HCV- related chronic hepatitis, 90 liver cirrhosis patients) and 40 matched healthy controls were studied. Both breath test and routine liver test, serum levels of cholic and chenodeoxycholic acid conjugates were evaluated. RESULTS: Methacetin breath test, expressed as 60 min cumulative percent of oxidation, discriminated the hepatic functional capacity not only between controls and liver disease patients, but also between different categories of chronic liver disease patients. Methacetin breath test was correlated with liver function tests and serum bile acids. Furthermore, methacetin breath test, as well as serum bile acids, were highly predictive of Child-Pugh scores. The diagnostic power of phenylalanine breath test was always less than that of methacetin breath test. CONCLUSION: Methacetin breath test represents a safe and accurate diagnostic tool in the evaluation of hepatic functional mass in chronic liver disease patients. PMID:15609414

  18. Respiratory comfort and breathing pattern during volume proportional assist ventilation and pressure support ventilation: a study on volunteers with artificially reduced compliance.

    PubMed

    Mols, G; von Ungern-Sternberg, B; Rohr, E; Haberthür, C; Geiger, K; Guttmann, J

    2000-06-01

    To assess respiratory comfort and associated breathing pattern during volume assist (VA) as a component of proportional assist ventilation and during pressure support ventilation (PSV). Prospective, double-blind, interventional study. Laboratory. A total of 15 healthy volunteers (11 females, 4 males) aged 21-31 yrs. Decreased respiratory system compliance was simulated by banding of the thorax and abdomen. Volunteers breathed via a mouthpiece with VA and PSV each applied at two levels (VA, 8 cm H2O/L and 12 cm H2O/L; PSV, 10 cm H2O and 15 cm H2O) using a positive end-expiratory pressure of 5 cm H2O throughout. The study was subdivided into two parts. In Part 1, volunteers breathed three times with each of the four settings for 2 mins in random order. In Part 2, the first breath effects of multiple, randomly applied mode, and level shifts were studied. In Part 1, the volunteers were asked to estimate respiratory comfort in comparison with normal breathing using a visual analog scale. In Part 2, they were asked to estimate the change of respiratory comfort as increased, decreased, or unchanged immediately after a mode shift. Concomitantly, the respiratory pattern (change) was characterized with continuously measured tidal volume, respiratory rate, pressure, and gas flow. Respiratory comfort during VA was higher than during PSV. The higher support level was less important during VA but had a major negative influence on comfort during PSV. Both modes differed with respect to the associated breathing pattern. Variability of breathing was higher during VA than during PSV (Part 1). Changes in respiratory variables were associated with changes in respiratory comfort (Part 2). For volunteers breathing with artificially reduced respiratory system compliance, respiratory comfort is higher with VA than with PSV. This is probably caused by a better adaptation of the ventilatory support to the volunteer's need with VA.

  19. Variability of exhaled breath condensate (EBC) volume and pH using a feedback regulated breathing pattern

    EPA Science Inventory

    Exhaled breath condensate (EBC) is a valuable biological medium for non-invasively measuring biomarkers with the potential to reflect organ systems responses to environmental and dietary exposures and disease processes. Collection of EBC has typically been with spontaneous breat...

  20. Detection of nitric oxide in exhaled human breath: exercise and resting determinations.

    PubMed

    Mantione, Kirk J; Esch, Tobias; Stefano, George B

    2007-03-01

    Nitric oxide has become a vital indicator of health since many cells produce it constitutively. It is present in exhaled breath and can be measured. A Kiernan NO Breath analyzer (KNB) was used in the present study to determine nitric oxide (NO) levels in exhaled human breath. The KNB was calibrated via measuring NO gas in O2-free N2 obtained from Scott Specialty Gases. Human subjects aged 21 to 45 were instructed to place the KNB over their nose and mouth and to breathe normally before and after mild exercise (n=24) and relaxation (n=20). Mean exhaled NO measurements were compared before and after the protocols using paired t-tests. Regardless of the test, all subjects exhibited NO in their exhaled breath. Exhaled NO decreased significantly after exercise compared to the first reading just prior to the exercise protocol. The mean +/-SE of exhaled NO was 22.8+/-4 before and 13.0+/-2 ppb after exercise (n=24, P=0.003). In the resting experiment, exhaled NO was demonstrated to increase significantly after 10 min compared to the reading taken right after the individuals sat down. The present study demonstrates NO in exhaled human breath can vary, reflecting the activity state of the individual. Additionally, the study demonstrates that NO in exhaled human breath can be measured rapidly, with high sensitivity, and in real time via the KNB, representing an affordable means to achieve this determination.

  1. A Portable Real-Time Ringdown Breath Acetone Analyzer: Toward Potential Diabetic Screening and Management

    PubMed Central

    Jiang, Chenyu; Sun, Meixiu; Wang, Zhennan; Chen, Zhuying; Zhao, Xiaomeng; Yuan, Yuan; Li, Yingxin; Wang, Chuji

    2016-01-01

    Breath analysis has been considered a suitable tool to evaluate diseases of the respiratory system and those that involve metabolic changes, such as diabetes. Breath acetone has long been known as a biomarker for diabetes. However, the results from published data by far have been inconclusive regarding whether breath acetone is a reliable index of diabetic screening. Large variations exist among the results of different studies because there has been no “best-practice method” for breath-acetone measurements as a result of technical problems of sampling and analysis. In this mini-review, we update the current status of our development of a laser-based breath acetone analyzer toward real-time, one-line diabetic screening and a point-of-care instrument for diabetic management. An integrated standalone breath acetone analyzer based on the cavity ringdown spectroscopy technique has been developed. The instrument was validated by using the certificated gas chromatography-mass spectrometry. The linear fittings suggest that the obtained acetone concentrations via both methods are consistent. Breath samples from each individual subject under various conditions in total, 1257 breath samples were taken from 22 Type 1 diabetic (T1D) patients, 312 Type 2 diabetic (T2D) patients, which is one of the largest numbers of T2D subjects ever used in a single study, and 52 non-diabetic healthy subjects. Simultaneous blood glucose (BG) levels were also tested using a standard diabetic management BG meter. The mean breath acetone concentrations were determined to be 4.9 ± 16 ppm (22 T1D), and 1.5 ± 1.3 ppm (312 T2D), which are about 4.5 and 1.4 times of the one in the 42 non-diabetic healthy subjects, 1.1 ± 0.5 ppm, respectively. A preliminary quantitative correlation (R = 0.56, p < 0.05) between the mean individual breath acetone concentration and the mean individual BG levels does exist in 20 T1D subjects with no ketoacidosis. No direct correlation is observed in T1D subjects, T

  2. A Portable Real-Time Ringdown Breath Acetone Analyzer: Toward Potential Diabetic Screening and Management.

    PubMed

    Jiang, Chenyu; Sun, Meixiu; Wang, Zhennan; Chen, Zhuying; Zhao, Xiaomeng; Yuan, Yuan; Li, Yingxin; Wang, Chuji

    2016-07-30

    Breath analysis has been considered a suitable tool to evaluate diseases of the respiratory system and those that involve metabolic changes, such as diabetes. Breath acetone has long been known as a biomarker for diabetes. However, the results from published data by far have been inconclusive regarding whether breath acetone is a reliable index of diabetic screening. Large variations exist among the results of different studies because there has been no "best-practice method" for breath-acetone measurements as a result of technical problems of sampling and analysis. In this mini-review, we update the current status of our development of a laser-based breath acetone analyzer toward real-time, one-line diabetic screening and a point-of-care instrument for diabetic management. An integrated standalone breath acetone analyzer based on the cavity ringdown spectroscopy technique has been developed. The instrument was validated by using the certificated gas chromatography-mass spectrometry. The linear fittings suggest that the obtained acetone concentrations via both methods are consistent. Breath samples from each individual subject under various conditions in total, 1257 breath samples were taken from 22 Type 1 diabetic (T1D) patients, 312 Type 2 diabetic (T2D) patients, which is one of the largest numbers of T2D subjects ever used in a single study, and 52 non-diabetic healthy subjects. Simultaneous blood glucose (BG) levels were also tested using a standard diabetic management BG meter. The mean breath acetone concentrations were determined to be 4.9 ± 16 ppm (22 T1D), and 1.5 ± 1.3 ppm (312 T2D), which are about 4.5 and 1.4 times of the one in the 42 non-diabetic healthy subjects, 1.1 ± 0.5 ppm, respectively. A preliminary quantitative correlation (R = 0.56, p < 0.05) between the mean individual breath acetone concentration and the mean individual BG levels does exist in 20 T1D subjects with no ketoacidosis. No direct correlation is observed in T1D subjects, T2D

  3. Comparison of the analytical capabilities of the BAC Datamaster and Datamaster DMT forensic breath testing devices.

    PubMed

    Glinn, Michele; Adatsi, Felix; Curtis, Perry

    2011-11-01

    The State of Michigan uses the Datamaster as an evidential breath testing device. The newest version, the DMT, will replace current instruments in the field as they are retired from service. The Michigan State Police conducted comparison studies to test the analytical properties of the new instrument and to evaluate its response to conditions commonly cited in court defenses. The effects of mouth alcohol, objects in the mouth, and radiofrequency interference on paired samples from drinking subjects were assessed on the DMT. The effects of sample duration and chemical interferents were assessed on both instruments, using drinking subjects and wet-bath simulators, respectively. Our testing shows that Datamaster and DMT results are essentially identical; the DMT gave accurate readings as compared with measurements made using simulators containing standard ethanol solutions and that the DMT did not give falsely elevated breath alcohol results from any of the influences tested. © 2011 American Academy of Forensic Sciences.

  4. TR-BREATH: Time-Reversal Breathing Rate Estimation and Detection.

    PubMed

    Chen, Chen; Han, Yi; Chen, Yan; Lai, Hung-Quoc; Zhang, Feng; Wang, Beibei; Liu, K J Ray

    2018-03-01

    In this paper, we introduce TR-BREATH, a time-reversal (TR)-based contact-free breathing monitoring system. It is capable of breathing detection and multiperson breathing rate estimation within a short period of time using off-the-shelf WiFi devices. The proposed system exploits the channel state information (CSI) to capture the miniature variations in the environment caused by breathing. To magnify the CSI variations, TR-BREATH projects CSIs into the TR resonating strength (TRRS) feature space and analyzes the TRRS by the Root-MUSIC and affinity propagation algorithms. Extensive experiment results indoor demonstrate a perfect detection rate of breathing. With only 10 s of measurement, a mean accuracy of can be obtained for single-person breathing rate estimation under the non-line-of-sight (NLOS) scenario. Furthermore, it achieves a mean accuracy of in breathing rate estimation for a dozen people under the line-of-sight scenario and a mean accuracy of in breathing rate estimation of nine people under the NLOS scenario, both with 63 s of measurement. Moreover, TR-BREATH can estimate the number of people with an error around 1. We also demonstrate that TR-BREATH is robust against packet loss and motions. With the prevailing of WiFi, TR-BREATH can be applied for in-home and real-time breathing monitoring.

  5. Design and Testing of an H2/O2 Predetonator for a Simulated Rotating Detonation Engine Channel

    DTIC Science & Technology

    2013-03-01

    Diameter PDE Pulse Detonation Engines RDE Rotating Detonation Engine WPAFB Wright Patterson Air Force Base ZND Zeldovich, von Neumann and Doring xv...DESIGN AND TESTING OF AN H2/O2 PREDETONATOR FOR A SIMULATED ROTATING DETONATION ENGINE CHANNEL THESIS Stephen J. Miller, 2Lt, USAF AFIT-ENY-13-M-23...RELEASE; DISTRIBUTION UNLIMITED AFIT-ENY-13-M-23 DESIGN AND TESTING OF AN H2/O2 PREDETONATOR FOR A SIMULATED ROTATING DETONATION ENGINE CHANNEL Stephen

  6. Does smoking abstinence influence distress tolerance? An experimental study comparing the response to a breath-holding test of smokers under tobacco withdrawal and under nicotine replacement therapy.

    PubMed

    Cosci, Fiammetta; Anna Aldi, Giulia; Nardi, Antonio Egidio

    2015-09-30

    Distress tolerance has been operationalized as task persistence in stressful behavioral laboratory tasks. According to the distress tolerance perspective, how an individual responds to discomfort/distress predicts early smoking lapses. This theory seems weakly supported by experimental studies since they are limited in number, show inconsistent results, do not include control conditions. We tested the response to a stressful task in smokers under abstinence and under no abstinence to verify if tobacco abstinence reduces task persistence, thus distress tolerance. A placebo-controlled, double-blind, randomized, cross-over design was used. Twenty smokers underwent a breath holding test after the administration of nicotine on one test day and a placebo on another test day. Physiological and psychological variables were assessed at baseline and directly before and after each challenge. Abstinence induced a statistically significant shorter breath holding duration relative to the nicotine condition. No different response to the breath holding test was observed when nicotine and placebo conditions were compared. No response to the breath holding test was found when pre- and post-test values of heart rate, blood pressure, Visual Analogue Scale for fear or discomfort were compared. In brief, tobacco abstinence reduces breath holding duration but breath holding test does not influence discomfort. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Air-breathing behavior and physiological responses to hypoxia and air exposure in the air-breathing loricariid fish, Pterygoplichthys anisitsi.

    PubMed

    da Cruz, André Luis; da Silva, Hugo Ribeiro; Lundstedt, Lícia Maria; Schwantes, Arno Rudi; Moraes, Gilberto; Klein, Wilfried; Fernandes, Marisa Narciso

    2013-04-01

    Hypoxic water and episodic air exposure are potentially life-threatening conditions that fish in tropical regions can face during the dry season. This study investigated the air-breathing behavior, oxygen consumption, and respiratory responses of the air-breathing (AB) armored catfish Pterygoplichthys anisitsi. The hematological parameters and oxygen-binding characteristics of whole blood and stripped hemoglobin and the intermediate metabolism of selected tissue in normoxia, different hypoxic conditions, and after air exposure were also examined. In normoxia, this species exhibited high activity at night and AB behavior (2-5 AB h(-1)). The exposure to acute severe hypoxia elicited the AB behavior (4 AB h(-1)) during the day. Under progressive hypoxia without access to the water surface, the fish were oxyregulators with a critical O2 tension, calculated as the inspired water O2 pressure, as 47 ± 2 mmHg. At water O2 tensions lower than 40 mmHg, the fish exhibited continuous apnea behavior. The blood exhibited high capacity for transporting O2, having a cathodic hemoglobin component with a high Hb-O2 affinity. Under severe hypoxia, the fish used anaerobic metabolism to maintain metabolic rate. Air exposure revealed physiological and biochemical traits similar to those observed under normoxic conditions.

  8. 32 CFR 634.37 - Voluntary breath and bodily fluid testing based on implied consent.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Traffic Supervision § 634.37 Voluntary breath and bodily fluid testing based on implied consent... the person was driving under the influence of alcohol or drugs. (3) A request was made to the person...

  9. 32 CFR 634.37 - Voluntary breath and bodily fluid testing based on implied consent.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Traffic Supervision § 634.37 Voluntary breath and bodily fluid testing based on implied consent... the person was driving under the influence of alcohol or drugs. (3) A request was made to the person...

  10. Measurement of fatigue following 18 msw dry chamber dives breathing air or enriched air nitrox.

    PubMed

    Harris, R J D; Doolette, D J; Wilkinson, D C; Williams, D J

    2003-01-01

    Many divers report less fatigue following diving breathing oxygen rich N2-O2 mixtures compared with breathing air. In this double blinded, randomized controlled study 11 divers breathed either air or Enriched Air Nitrox 36% (oxygen 36%, nitrogen 64%) during an 18 msw (281 kPa(a)) dry chamber dive for a bottom time of 40 minutes. Two periods of exercise were performed during the dive. Divers were assessed before and after each dive using the Multidimensional Fatigue Inventory-20, a visual analogue scale, Digit Span Tests, Stroop Tests, and Divers Health Survey (DHS). Diving to 18m produced no measurable difference in fatigue, attention levels, ability to concentrate or DHS scores, following dives using either breathing gas.

  11. Breath hydrogen and methane are associated with intestinal symptoms in patients with chronic pancreatitis.

    PubMed

    Kim, Dae Bum; Paik, Chang-Nyol; Sung, Hea Jung; Chung, Woo Chul; Lee, Kang-Moon; Yang, Jin-Mo; Choi, Myung-Gyu

    2015-01-01

    The bacterial overgrowth might be associated with chronic pancreatitis. This study was to evaluate the prevalence and characteristics of small intestinal bacterial overgrowth (SIBO) in patients with chronic pancreatitis. 36 patients with chronic pancreatitis and 49 healthy controls undergoing the hydrogen (H2)-methane (CH4) lactulose breath test (LBT) were reviewed. The LBT positivity (+) indicating the presence of SIBO, gas types, bowel symptom questionnaire, laboratory and radiologic results were surveyed. The LBT+ was (1) an increase in the breath H2 (≥20 ppm) or CH4 (≥10 ppm) over the baseline or (2) a baseline H2 (≥20 ppm) or CH4 (≥10 ppm) within 90 min after lactulose load. LBT+ was significantly higher in the patients (17/36) than in controls (13/49) (47.2% vs. 26.5%, P < 0.05). During LBT, the H2 levels between 0 and 105 min were significantly higher in patients than in controls. Among LBT+ patients, 11 (64.7%), 1 (5.9%), 5 (29.4%) were in the LBT (H2)+, (CH4)+, (mixed)+ groups, respectively. The LBT+ group had significantly higher scores of flatus than those of the LBT- group. Considering the subtypes of LBT, the LBT (mixed)+ group had higher symptom scores of significance or tendency in hard stool, strain, urgency, and flatus than LBT- group The laboratory and radiologic features were not significantly different between LBT+ and LBT- groups. SIBO is common in patients in chronic pancreatitis. Especially, excretions of mixed H2 and CH4 appear to be related with deterioration of intestinal symptoms. Copyright © 2015 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  12. Sensing the effects of mouth breathing by using 3-tesla MRI

    NASA Astrophysics Data System (ADS)

    Park, Chan-A.; Kang, Chang-Ki

    2017-06-01

    We investigated the effects of mouth breathing and typical nasal breathing on brain function by using blood-oxygenation-level-dependent (BOLD) functional magnetic resonance imaging (fMRI). The study had two parts: the first test was a simple contrast between mouth and nasal breathing, and the second test involved combined breathing modes, e.g., mouth inspiration and nasal expiration. Eleven healthy participants performed the combined breathing task while undergoing 3T fMRI. In the group-level analysis, contrast images acquired by using an individual participantlevel analysis were processed using the one-sample t test. We also conducted a region-of-interest analysis comparing signal intensity changes between the breathing modes; the region was selected using an automated anatomical labeling map. The results demonstrated that the BOLD signal in the hippocampus and brainstem was significantly decreased in mouth breathing relative to nasal breathing. On the other hand, both the precentral and postcentral gyri showed activation that was more significant in mouth breathing compared to nasal breathing. This study suggests that the BOLD activity patterns between mouth and nasal breathing may be induced differently, especially in the hippocampus, which could provide clues to explain the effects on brain cognitive function due to mouth breathing.

  13. Breath Methane Excretion Is not An Accurate Marker of Colonic Methane Production in Irritable Bowel Syndrome.

    PubMed

    Di Stefano, Michele; Mengoli, Caterina; Bergonzi, Manuela; Klersy, Catherine; Pagani, Elisabetta; Miceli, Emanuela; Corazza, Gino Roberto

    2015-06-01

    The role of colonic methane production in functional bowel disorders is still uncertain. In small samples of irritable bowel syndrome (IBS) patients, it was shown that methane breath excretion correlates with clinical presentation and delayed gastrointestinal transit time. The aim of this study was to evaluate the relationship between intestinal production and breath excretion of CH4 and to correlate CH4 production with the presence and the severity of symptoms, in a large cohort of IBS patients and in a group of healthy volunteers. A group of 103 IBS patients and a group of 28 healthy volunteers were enrolled. The presence and severity of symptoms and gastrointestinal transit were evaluated in all subjects, who underwent breath H2/CH4 measurement for 7 h after lactulose to identify breath excretors of these gases; H2 and CH4 were also measured in rectal samples to identify colonic producers. Cumulative H2 and CH4 excretion and production were evaluated by the area under the time-concentration curve calculation (AUC). In IBS patients, CH4 was detected in rectal samples in 48 patients (47%), but only 27 of them (26% of the 103 enrolled patients) excreted this gas with breath. In CH4 producers, the prevalence and severity of symptoms and gastrointestinal transit time were not significantly different with respect to non-producers. IBS subtypes were homogeneously represented in CH4 producers and in non-producers. Healthy volunteers, compared with IBS patients, showed a significantly lower prevalence of CH4 excretion, whereas no difference was found in the prevalence of colonic CH4 production; moreover, in healthy volunteers compared with IBS, CH4 breath excretion and CH4 production were not different in quantitative terms. Our data show that colonic CH4 production is not associated with clinical presentation in IBS patients and does not correlate with symptom severity or with gastrointestinal transit time. Clinical inferences based on breath CH4 excretion should

  14. Breath-hold times in air compared to breath-hold times during cold water immersions.

    PubMed

    Taber, Michael J; MacKinnon, Scott N; Power, Jonathan; Walker, Robert

    2015-02-01

    Given the effects of cold water immersion on breath-hold (BH) capabilities, a practical training exercise was developed for military/paramilitary personnel completing a helicopter underwater egress training (HUET) program. The exercise was designed to provide firsth and experience of the effects of cold water exposure on BH time. After completing the required HUET, 47 subjects completed two BH testing sessions as well as a short questionnaire. The first BH was completed while standing on the pool deck. The second BH was completed while fully immersed (face down) in 2-3°C water. There were 40 of the volunteers who also breathed from an emergency breathing system (EBS) while in the cold water. Results demonstrated that BH capabilities in cold water were significantly lower than those in ambient air. A significant correlation was also found between BH in air and the difference in cold water vs. air BH capabilities, which suggests that subjects who can hold their breath the longest in air experienced the greatest decrease in BH when immersed. Results indicate that 92% of the subjects reported that the practical cold water immersion exercise had a high value. Finally, 58% of those who used the EBS reported that it was harder to breathe in cold water than while in the training pool (approximately 22°C). The BH times for this group were similar to those reported in previous cold water immersion studies. Based on the questionnaire results, it is possible, when carefully applied, to include a practical cold water immersion exercise into existing HUET programs.

  15. eAMI: A Qualitative Quantification of Periodic Breathing Based on Amplitude of Oscillations

    PubMed Central

    Fernandez Tellez, Helio; Pattyn, Nathalie; Mairesse, Olivier; Dolenc-Groselj, Leja; Eiken, Ola; Mekjavic, Igor B.; Migeotte, P. F.; Macdonald-Nethercott, Eoin; Meeusen, Romain; Neyt, Xavier

    2015-01-01

    Study Objectives: Periodic breathing is sleep disordered breathing characterized by instability in the respiratory pattern that exhibits an oscillatory behavior. Periodic breathing is associated with increased mortality, and it is observed in a variety of situations, such as acute hypoxia, chronic heart failure, and damage to respiratory centers. The standard quantification for the diagnosis of sleep related breathing disorders is the apnea-hypopnea index (AHI), which measures the proportion of apneic/hypopneic events during polysomnography. Determining the AHI is labor-intensive and requires the simultaneous recording of airflow and oxygen saturation. In this paper, we propose an automated, simple, and novel methodology for the detection and qualification of periodic breathing: the estimated amplitude modulation index (eAMI). Patients or Participants: Antarctic cohort (3,800 meters): 13 normal individuals. Clinical cohort: 39 different patients suffering from diverse sleep-related pathologies. Measurements and Results: When tested in a population with high levels of periodic breathing (Antarctic cohort), eAMI was closely correlated with AHI (r = 0.95, P < 0.001). When tested in the clinical setting, the proposed method was able to detect portions of the signal in which subclinical periodic breathing was validated by an expert (n = 93; accuracy = 0.85). Average eAMI was also correlated with the loop gain for the combined clinical and Antarctica cohorts (r = 0.58, P < 0.001). Conclusions: In terms of quantification and temporal resolution, the eAMI is able to estimate the strength of periodic breathing and the underlying loop gain at any given time within a record. The impaired prognosis associated with periodic breathing makes its automated detection and early diagnosis of clinical relevance. Citation: Fernandez Tellez H, Pattyn N, Mairesse O, Dolenc-Groselj L, Eiken O, Mekjavic IB, Migeotte PF, Macdonald-Nethercott E, Meeusen R, Neyt X. eAMI: a qualitative

  16. Breath measurement instrumentation as alcohol safety interlock systems

    DOT National Transportation Integrated Search

    1974-09-01

    This report describes the results of field tests of in-car instruments which measure alcohol on the driver's breath and prevent him from operating his vehicle if intoxicated. Two types of breath alcohol sensors were used for these tests; a fuel-cell ...

  17. NASA firefighters breathing system program report

    NASA Technical Reports Server (NTRS)

    Wood, W. B.

    1977-01-01

    Because of the rising incidence of respiratory injury to firefighters, local governments expressed the need for improved breathing apparatus. A review of the NASA firefighters breathing system program, including concept definition, design, development, regulatory agency approval, in-house testing, and program conclusion is presented.

  18. A comparison of blood alcohol levels as determined by breath and blood tests taken in actual field operations.

    DOT National Transportation Integrated Search

    1972-01-01

    During its 1972 session, the General Assembly of Virginia enacted Senate Bill 104, which authorizes the breath test, as well as the blood test used previously, as a proper chemical test to determine the alcoholic content of the blood. Any person arre...

  19. Breathing exercises in upper abdominal surgery: a systematic review and meta-analysis.

    PubMed

    Grams, Samantha T; Ono, Lariane M; Noronha, Marcos A; Schivinski, Camila I S; Paulin, Elaine

    2012-01-01

    There is currently no consensus on the indication and benefits of breathing exercises for the prevention of postoperative pulmonary complications PPCs and for the recovery of pulmonary mechanics. To undertake a systematic review of randomized and quasi-randomized studies that assessed the effects of breathing exercises on the recovery of pulmonary function and prevention of PCCs after upper abdominal surgery UAS. We searched the Physiotherapy Evidence Database PEDro, Scientific Electronic Library Online SciELO, MEDLINE, and Cochrane Central Register of Controlled Trials. We included randomized controlled trials and quasi-randomized controlled trials on pre- and postoperative UAS patients, in which the primary intervention was breathing exercises without the use of incentive inspirometers. The methodological quality of the studies was rated according to the PEDro scale. Data on maximal respiratory pressures MIP and MEP, spirometry, diaphragm mobility, and postoperative complications were extracted and analyzed. Data were pooled in fixed-effect meta-analysis whenever possible. Six studies were used for analysis. Two meta-analyses including 66 participants each showed that, on the first day post-operative, the breathing exercises were likely to have induced MEP and MIP improvement treatment effects of 11.44 mmH2O (95%CI 0.88 to 22) and 11.78 mmH2O (95%CI 2.47 to 21.09), respectively. Breathing exercises are likely to have a beneficial effect on respiratory muscle strength in patients submitted to UAS, however the lack of good quality studies hinders a clear conclusion on the subject.

  20. A breath test for malignant mesothelioma using an electronic nose.

    PubMed

    Chapman, Eleanor A; Thomas, Paul S; Stone, Emily; Lewis, Craig; Yates, Deborah H

    2012-08-01

    Malignant mesothelioma (MM) is a rare tumour which is difficult to diagnose in its early stages. Earlier detection of MM could potentially improve survival. Exhaled breath sampling of volatile organic compounds (VOCs) using a carbon polymer array (CPA) electronic nose recognises specific breath profiles characteristic of different diseases, and can distinguish between patients with lung cancer and controls. With MM, the potential confounding effect of other asbestos-related diseases (ARDs) needs to be considered. We hypothesised that as CPA electronic nose would distinguish patients with MM, patients with benign ARDs, and controls with high sensitivity and specificity. 20 MM, 18 ARD and 42 control subjects participated in a cross-sectional, case-control study. Breath samples were analysed using the Cyranose 320 (Smiths Detection, Pasadena, CA, USA), using canonical discriminant analysis and principal component reduction. 10 MM subjects created the training set. Smell prints from 10 new MM patients were distinguished from control subjects with an accuracy of 95%. Patients with MM, ARDs and control subjects were correctly identified in 88% of cases. Exhaled breath VOC profiling can accurately distinguish between patients with MM, ARDs and controls using a CPA electronic nose. This could eventually translate into a screening tool for high-risk populations.

  1. DEVELOPMENT OF A SCREENING PROTOCOL TO IDENTIFY INDIVIDUALS WITH DYSFUNCTIONAL BREATHING

    PubMed Central

    Kiesel, Kyle; Rhodes, Tonya; Mueller, Jacob; Waninger, Alyssa; Butler, Robert

    2017-01-01

    Introduction Dysfunctional breathing (DB) has been linked to health conditions including low back pain and neck pain and adversely effects the musculoskeletal system. Individuals with DB often have decreased pain thresholds and impaired motor control, balance, and movement. No single test or screen identifies DB, which is multi-dimensional, and includes biochemical, biomechanical, and psychophysiological components. Several tools assess and test for DB, but no screen exists to determine whether additional testing and assessment are indicated. Purpose/Background The purpose of this study was to develop a breathing screening procedure that could be utilized by fitness and healthcare providers to screen for the presence of disordered breathing. A diagnostic test study approach was utilized to establish the diagnostic accuracy of the newly developed screen for DB. Methods A convenience sample of 51 subjects (27 females, 27.0 years, BMI 23.3) were included. To test for DB related to the biochemical dimension, end-tidal CO2 (ETCO2) was measured with a capnography unit. To test for DB related to biomechanical dimension, the Hi-Lo test was utilized. To test for DB related to the psychophysiological dimension, the Self Evaluation of Breathing Symptoms Questionnaire (SEBQ) and Nijmegen questionnaires were utilized. Potential screening items that have been shown to be related to DB in previous research and that could be performed by non-health care personnel were utilized to create the index test including activity level, breath hold time (BHT), respiration rate, and the Functional Movement Screen (FMS™). Results There were no strong correlations between the three measures of DB. Five subjects had normal breathing, 14 failed at least one measure, 20 failed at least two, and 12 failed all three. To develop screening items for each dimension, data were examined for association with failure. BHT and a four-item mini-questionnaire were identified as the most closely associated

  2. Hypersonic propulsion flight tests as essential to air-breathing aerospace plane development

    NASA Astrophysics Data System (ADS)

    Mehta, U.

    Hypersonic air-breathing propulsion utilizing scramjets can fundamentally change transatmospheric acclerators for transportation from low Earth orbits (LEOs). The value and limitations of ground tests, of flight tests, and of computations are presented, and scramjet development requirements are discussed. Near-full-scale hypersonic propulsion flight tests are essential for developing a prototype hypersonic propulsion system and for developing computation-design technology that can be used in designing that system. In order to determine how these objectives should be achieved, some lessons learned from past programs are presented. A conceptual two-stage-to-orbit (TSTO) prototype/experimental aerospace plane is recommended as a means of providing access-to-space and for conducting flight tests. A road map for achieving these objectives is also presented.

  3. Design and Validation of a Breathing Detection System for Scuba Divers.

    PubMed

    Altepe, Corentin; Egi, S Murat; Ozyigit, Tamer; Sinoplu, D Ruzgar; Marroni, Alessandro; Pierleoni, Paola

    2017-06-09

    Drowning is the major cause of death in self-contained underwater breathing apparatus (SCUBA) diving. This study proposes an embedded system with a live and light-weight algorithm which detects the breathing of divers through the analysis of the intermediate pressure (IP) signal of the SCUBA regulator. A system composed mainly of two pressure sensors and a low-power microcontroller was designed and programmed to record the pressure sensors signals and provide alarms in absence of breathing. An algorithm was developed to analyze the signals and identify inhalation events of the diver. A waterproof case was built to accommodate the system and was tested up to a depth of 25 m in a pressure chamber. To validate the system in the real environment, a series of dives with two different types of workload requiring different ranges of breathing frequencies were planned. Eight professional SCUBA divers volunteered to dive with the system to collect their IP data in order to participate to validation trials. The subjects underwent two dives, each of 52 min on average and a maximum depth of 7 m. The algorithm was optimized for the collected dataset and proved a sensitivity of inhalation detection of 97.5% and a total number of 275 false positives (FP) over a total recording time of 13.9 h. The detection algorithm presents a maximum delay of 5.2 s and requires only 800 bytes of random-access memory (RAM). The results were compared against the analysis of video records of the dives by two blinded observers and proved a sensitivity of 97.6% on the data set. The design includes a buzzer to provide audible alarms to accompanying dive buddies which will be triggered in case of degraded health conditions such as near drowning (absence of breathing), hyperventilation (breathing frequency too high) and skip-breathing (breathing frequency too low) measured by the improper breathing frequency. The system also measures the IP at rest before the dive and indicates with flashing light

  4. Deep-breathing exercises reduce atelectasis and improve pulmonary function after coronary artery bypass surgery.

    PubMed

    Westerdahl, Elisabeth; Lindmark, Birgitta; Eriksson, Tomas; Friberg, Orjan; Hedenstierna, Göran; Tenling, Arne

    2005-11-01

    To investigate the effects of deep-breathing exercises on pulmonary function, atelectasis, and arterial blood gas levels after coronary artery bypass graft (CABG) surgery. In a prospective, randomized trial, patients performing deep-breathing exercises (n = 48) were compared to a control group (n = 42) who performed no breathing exercises postoperatively. Patient management was similar in the groups in terms of assessment, positioning, and mobility. The patients in the deep-breathing group were instructed to perform breathing exercises hourly during daytime for the first 4 postoperative days. The exercises consisted of 30 slow, deep breaths performed with a positive expiratory pressure blow-bottle device (+ 10 cm H(2)O). Spirometric measurements, spiral CT (three transverse levels), arterial blood gas analysis, and scoring of subjective experience of the breathing exercises were performed on the fourth postoperative day. Atelectasis was only half the size in the deep-breathing group compared to the control group, amounting to 2.6 +/- 2.2% vs 4.7 +/- 5.7% (p = 0.045) at the basal level and 0.1 +/- 0.2% vs 0.3 +/- 0.5% (mean +/- SD) [p = 0.01] at the apical level. Compared to the control subjects, the patients in the deep-breathing group had a significantly smaller reduction in FVC (to 71 +/- 12%, vs 64 +/- 13% of the preoperative values; p = 0.01) and FEV(1) (to 71 +/- 11%, vs 65 +/- 13% of the preoperative values; p = 0.01). Arterial oxygen tension, carbon dioxide tension, fever, or length of ICU or hospital stay did not differ between the groups. In the deep-breathing group, 72% of the patients experienced a subjective benefit from the exercises. Patients performing deep-breathing exercises after CABG surgery had significantly smaller atelectatic areas and better pulmonary function on the fourth postoperative day compared to a control group performing no exercises.

  5. Exhaled breath analysis for lung cancer

    PubMed Central

    Sutedja, Tom G.; Zimmerman, Paul V.

    2013-01-01

    Early diagnosis of lung cancer results in improved survival compared to diagnosis with more advanced disease. Early disease is not reliably indicated by symptoms. Because investigations such as bronchoscopy and needle biopsy have associated risks and substantial costs, they are not suitable for population screening. Hence new easily applicable tests, which can be used to screen individuals at risk, are required. Biomarker testing in exhaled breath samples is a simple, relatively inexpensive, non-invasive approach. Exhaled breath contains volatile and non-volatile organic compounds produced as end-products of metabolic processes and the composition of such compounds varies between healthy subjects and subjects with lung cancer. Many studies have analysed the patterns of these compounds in exhaled breath. In addition studies have also reported that the exhaled breath condensate (EBC) can reveal gene mutations or DNA abnormalities in patients with lung cancer. This review has summarised the scientific evidence demonstrating that lung cancer has distinct chemical profiles in exhaled breath and characteristic genetic changes in EBC. It is not yet possible to accurately identify individuals with lung cancer in at risk populations by any of these techniques. However, analysis of both volatile organic compounds in exhaled breath and of EBC have great potential to become clinically useful diagnostic and screening tools for early stage lung cancer detection. PMID:24163746

  6. Controlled breathing protocols probe human autonomic cardiovascular rhythms

    NASA Technical Reports Server (NTRS)

    Cooke, W. H.; Cox, J. F.; Diedrich, A. M.; Taylor, J. A.; Beightol, L. A.; Ames, J. E. 4th; Hoag, J. B.; Seidel, H.; Eckberg, D. L.

    1998-01-01

    The purpose of this study was to determine how breathing protocols requiring varying degrees of control affect cardiovascular dynamics. We measured inspiratory volume, end-tidal CO2, R-R interval, and arterial pressure spectral power in 10 volunteers who followed the following 5 breathing protocols: 1) uncontrolled breathing for 5 min; 2) stepwise frequency breathing (at 0.3, 0.25, 0.2, 0.15, 0.1, and 0.05 Hz for 2 min each); 3) stepwise frequency breathing as above, but with prescribed tidal volumes; 4) random-frequency breathing (approximately 0.5-0.05 Hz) for 6 min; and 5) fixed-frequency breathing (0.25 Hz) for 5 min. During stepwise breathing, R-R interval and arterial pressure spectral power increased as breathing frequency decreased. Control of inspired volume reduced R-R interval spectral power during 0.1 Hz breathing (P < 0.05). Stepwise and random-breathing protocols yielded comparable coherence and transfer functions between respiration and R-R intervals and systolic pressure and R-R intervals. Random- and fixed-frequency breathing reduced end-tidal CO2 modestly (P < 0.05). Our data suggest that stringent tidal volume control attenuates low-frequency R-R interval oscillations and that fixed- and random-rate breathing may decrease CO2 chemoreceptor stimulation. We conclude that autonomic rhythms measured during different breathing protocols have much in common but that a stepwise protocol without stringent control of inspired volume may allow for the most efficient assessment of short-term respiratory-mediated autonomic oscillations.

  7. Phox2b-expressing retrotrapezoid neurons and the integration of central and peripheral chemosensory control of breathing in conscious rats.

    PubMed

    Takakura, Ana C; Barna, Bárbara F; Cruz, Josiane C; Colombari, Eduardo; Moreira, Thiago S

    2014-03-01

    Chemoreception is the classic mechanism by which the brain regulates breathing in response to changes in tissue CO2/H(+). A brainstem region called the retrotrapezoid nucleus (RTN) contains a population of Phox2b-expressing glutamatergic neurons that appear to function as important chemoreceptors. In the present study, we ask whether the destruction of a type of pH-sensitive interneuron that expresses the transcription factor Phox2b and is non-catecholaminergic (Phox2b(+)TH(-)) could affect breathing in conscious adult rats. The injection of substance P (1 nmol in a volume of 50 nl) into the RTN increased respiratory frequency, tidal volume, minute ventilation and mean arterial pressure. Bilateral injections of the toxin substance P conjugated with saporin (SSP-SAP) into the RTN destroyed Phox2b(+)TH(-) neurons but spared facial motoneurons, catecholaminergic and serotonergic neurons and the ventral respiratory column caudal to the facial motor nucleus. Bilateral inhibition of RTN neurons with SSP-SAP (0.6 ng in 30 nl) reduced resting ventilation and the increase in ventilation produced by hypercapnia (7% CO2) in conscious rats with or without peripheral chemoreceptors. In anaesthetized rats with bilateral lesions of around 90% of the Phox2b(+)TH(-) neurons, acute activation of the Bötzinger complex, the pre-Bötzinger complex or the rostral ventral respiratory group with NMDA (5 pmol in 50 nl) elicited normal cardiorespiratory output. In conclusion, the destruction of the Phox2b(+)TH(-) neurons is a plausible cause of the respiratory deficits observed after injection of SSP-SAP into the RTN. Our results also suggest that RTN neurons activate facilitatory mechanisms important to the control of breathing in resting or hypercapnic conditions in conscious adult rats.

  8. Air breathing and aquatic gas exchange during hypoxia in armoured catfish.

    PubMed

    Scott, Graham R; Matey, Victoria; Mendoza, Julie-Anne; Gilmour, Kathleen M; Perry, Steve F; Almeida-Val, Vera M F; Val, Adalberto L

    2017-01-01

    Air breathing in fish is commonly believed to have arisen as an adaptation to aquatic hypoxia. The effectiveness of air breathing for tissue O 2 supply depends on the ability to avoid O 2 loss as oxygenated blood from the air-breathing organ passes through the gills. Here, we evaluated whether the armoured catfish (Hypostomus aff. pyreneusi)-a facultative air breather-can avoid branchial O 2 loss while air breathing in aquatic hypoxia, and we measured various other respiratory and metabolic traits important for O 2 supply and utilization. Fish were instrumented with opercular catheters to measure the O 2 tension (PO 2 ) of expired water, and air breathing and aquatic respiration were measured during progressive stepwise hypoxia in the water. Armoured catfish exhibited relatively low rates of O 2 consumption and gill ventilation, and gill ventilation increased in hypoxia due primarily to increases in ventilatory stroke volume. Armoured catfish began air breathing at a water PO 2 of 2.5 kPa, and both air-breathing frequency and hypoxia tolerance (as reflected by PO 2 at loss of equilibrium, LOE) was greater in individuals with a larger body mass. Branchial O 2 loss, as reflected by higher PO 2 in expired than in inspired water, was observed in a minority (4/11) of individuals as water PO 2 approached that at LOE. Armoured catfish also exhibited a gill morphology characterized by short filaments bearing short fused lamellae, large interlamellar cell masses, low surface area, and a thick epithelium that increased water-to-blood diffusion distance. Armoured catfish had a relatively low blood-O 2 binding affinity when sampled in normoxia (P 50 of 3.1 kPa at pH 7.4), but were able to rapidly increase binding affinity during progressive hypoxia exposure (to a P 50 of 1.8 kPa). Armoured catfish also had low activities of several metabolic enzymes in white muscle, liver, and brain. Therefore, low rates of metabolism and gill ventilation, and a reduction in branchial gas

  9. Breath stacking in children with neuromuscular disorders.

    PubMed

    Jenkins, H M; Stocki, A; Kriellaars, D; Pasterkamp, H

    2014-06-01

    Respiratory muscle weakness in neuromuscular disorders (NMD) can lead to shallow breathing and respiratory insufficiency over time. Children with NMD often cannot perform maneuvers to recruit lung volume. In adults, breath stacking with a mask and one-way valve can achieve significantly increased lung volumes. To evaluate involuntary breath stacking (IBS) in NMD, we studied 23 children of whom 15 were cognitively aware and able to communicate verbally. For IBS, a one-way valve and pneumotachograph were attached to a face mask. Tidal volumes (Vt) and minute ventilation (VE ) were calculated from airflow over 30 sec before and after 15 sec of expiratory valve closure. Six cooperative male subjects with Duchenne muscular dystrophy (DMD) participated in a subsequent comparison of IBS with voluntary breath stacking (VBS) and supported breath stacking (SBS). The average Vt in those studied with IBS was 277 ml (range 29-598 ml). The average increase in volume by stacking was 599 ml (range -140 to 2,916 ml) above Vt . The average number of stacked breaths was 4.5 (range 0-17). VE increased on average by 18% after stacking (P < 0.05, paired t-test). Oxygen saturation did not change after stacking. Four of the 23 children did not breath stack. Compared to IBS, VBS achieved similar volumes in the six subjects with DMD but SBS was more successful in those with greatest muscle weakness. IBS may achieve breath volumes of approximately three times Vt and may be particularly useful in non-cooperative subjects with milder degrees of respiratory muscle weakness. © 2013 Wiley Periodicals, Inc.

  10. Adhesion of volatile propofol to breathing circuit tubing.

    PubMed

    Lorenz, Dominik; Maurer, Felix; Trautner, Katharina; Fink, Tobias; Hüppe, Tobias; Sessler, Daniel I; Baumbach, Jörg Ingo; Volk, Thomas; Kreuer, Sascha

    2017-08-21

    Propofol in exhaled breath can be measured and may provide a real-time estimate of plasma concentration. However, propofol is absorbed in plastic tubing, thus estimates may fail to reflect lung/blood concentration if expired gas is not extracted directly from the endotracheal tube. We evaluated exhaled propofol in five ventilated ICU patients who were sedated with propofol. Exhaled propofol was measured once per minute using ion mobility spectrometry. Exhaled air was sampled directly from the endotracheal tube and at the ventilator end of the expiratory side of the anesthetic circuit. The circuit was disconnected from the patient and propofol was washed out with a separate clean ventilator. Propofol molecules, which discharged from the expiratory portion of the breathing circuit, were measured for up to 60 h. We also determined whether propofol passes through the plastic of breathing circuits. A total of 984 data pairs (presented as median values, with 95% confidence interval), consisting of both concentrations were collected. The concentration of propofol sampled near the patient was always substantially higher, at 10.4 [10.25-10.55] versus 5.73 [5.66-5.88] ppb (p < 0.001). The reduction in concentration over the breathing circuit tubing was 4.58 [4.48-4.68] ppb, 3.46 [3.21-3.73] in the first hour, 4.05 [3.77-4.34] in the second hour, and 4.01 [3.36-4.40] in the third hour. Out-gassing propofol from the breathing circuit remained at 2.8 ppb after 60 h of washing out. Diffusion through the plastic was not observed. Volatile propofol binds or adsorbs to the plastic of a breathing circuit with saturation kinetics. The bond is reversible so propofol can be washed out from the plastic. Our data confirm earlier findings that accurate measurements of volatile propofol require exhaled air to be sampled as close as possible to the patient.

  11. Determination of volatile organic compounds in human breath for Helicobacter pylori detection by SPME-GC/MS.

    PubMed

    Ulanowska, Agnieszka; Kowalkowski, Tomasz; Hrynkiewicz, Katarzyna; Jackowski, Marek; Buszewski, Bogusław

    2011-03-01

    Helicobacter pylori living in the human stomach release volatile organic compounds (VOCs) that can be detected in expired air. The aim of the study was the application of breath analysis for bacteria detection. It was accomplished by determination of VOCs characteristic for patients with H. pylori and the analysis of gases released by bacteria in suspension. Solid-phase microextraction was applied as a selective technique for preconcentration and isolation of analytes. Gas chromatography coupled with mass spectrometry was used for the separation and identification of volatile analytes in breath samples and bacterial headspace. For data calculation and processing, discriminant and factor analyses were used. Endogenous substances such as isobutane, 2-butanone and ethyl acetate were detected in the breath of persons with H. pylori in the stomach and in the gaseous mixture released by the bacteria strain but they were not identified in the breath of healthy volunteers. The canonical analysis of discrimination functions showed a strong difference between the three examined groups. Knowledge of substances emitted by H. pylori with the application of an optimized breath analysis method might become a very useful tool for noninvasive detection of this bacterium. Copyright © 2010 John Wiley & Sons, Ltd.

  12. Work of breathing using different interfaces in spontaneous positive pressure ventilation: helmet, face-mask, and endotracheal tube.

    PubMed

    Oda, Shinya; Otaki, Kei; Yashima, Nozomi; Kurota, Misato; Matsushita, Sachiko; Kumasaka, Airi; Kurihara, Hutaba; Kawamae, Kaneyuki

    2016-08-01

    Noninvasive positive pressure ventilation (NPPV) using a helmet is expected to cause inspiratory trigger delay due to the large collapsible and compliant chamber. We compared the work of breathing (WOB) of NPPV using a helmet or a full face-mask with that of invasive ventilation by tracheal intubation. We used a lung model capable of simulating spontaneous breathing (LUNGOO; Air Water Inc., Japan). LUNGOO was set at compliance (C) = 50 mL/cmH2O and resistance (R) = 5 cmH2O/L/s for normal lung simulation, C = 20 mL/cmH2O and R = 5 cmH2O/L/s for restrictive lung, and C = 50 mL/cmH2O and R = 20 cmH2O/L/s for obstructive lung. Muscle pressure was fixed at 25 cmH2O and respiratory rate at 20 bpm. Pressure support ventilation and continuous positive airway pressure were performed with each interface placed on a dummy head made of reinforced plastic that was connected to LUNGOO. We tested the inspiratory WOB difference between the interfaces with various combinations of ventilator settings (positive end-expiratory pressure 5 cmH2O; pressure support 0, 5, and 10 cmH2O). In the normal lung and restrictive lung models, WOB decreased more with the face-mask than the helmet, especially when accompanied by the level of pressure support. In the obstructive lung model, WOB with the helmet decreased compared with the other two interfaces. In the mixed lung model, there were no significant differences in WOB between the three interfaces. NPPV using a helmet is more effective than the other interfaces for WOB in obstructive lung disease.

  13. Selective Hydrogen Isotope Separation via Breathing Transition in MIL-53(Al).

    PubMed

    Kim, Jin Yeong; Zhang, Linda; Balderas-Xicohténcatl, Rafael; Park, Jaewoo; Hirscher, Michael; Moon, Hoi Ri; Oh, Hyunchul

    2017-12-13

    Breathing of MIL-53(Al), a flexible metal-organic framework (MOF), leads to dynamic changes as narrow pore (np) transitions to large pore (lp). During the flexible and reversible transition, the pore apertures are continuously adjusted, thus providing the tremendous opportunity to separate mixtures of similar-sized and similar-shaped molecules that require precise pore tuning. Herein, for the first time, we report a strategy for effectively separating hydrogen isotopes through the dynamic pore change during the breathing of MIL-53(Al), a representative of flexible MOFs. The experiment shows that the selectivity for D 2 over H 2 is strongly related to the state of the pore structure of MIL-53(Al). The highest selectivity (S D 2 /H 2 = 13.6 at 40 K) was obtained by optimizing the exposure temperature, pressure, and time to systematically tune the pore state of MIL-53(Al).

  14. All APAPs Are Not Equivalent for the Treatment of Sleep Disordered Breathing: A Bench Evaluation of Eleven Commercially Available Devices.

    PubMed

    Zhu, Kaixian; Roisman, Gabriel; Aouf, Sami; Escourrou, Pierre

    2015-07-15

    This study challenged on a bench-test the efficacy of auto-titrating positive airway pressure (APAP) devices for obstructive sleep disordered breathing treatment and evaluated the accuracy of the device reports. Our bench consisted of an active lung simulator and a Starling resistor. Eleven commercially available APAP devices were evaluated on their reactions to single-type SDB sequences (obstructive apnea and hypopnea, central apnea, and snoring), and to a long general breathing scenario (5.75 h) simulating various SDB during four sleep cycles and to a short scenario (95 min) simulating one sleep cycle. In the single-type sequence of 30-minute repetitive obstructive apneas, only 5 devices normalized the airflow (> 70% of baseline breathing amplitude). Similarly, normalized breathing was recorded with 8 devices only for a 20-min obstructive hypopnea sequence. Five devices increased the pressure in response to snoring. Only 4 devices maintained a constant minimum pressure when subjected to repeated central apneas with an open upper airway. In the long general breathing scenario, the pressure responses and the treatment efficacy differed among devices: only 5 devices obtained a residual obstructive AHI < 5/h. During the short general breathing scenario, only 2 devices reached the same treatment efficacy (p < 0.001), and 3 devices underestimated the AHI by > 10% (p < 0.001). The long scenario led to more consistent device reports. Large differences between APAP devices in the treatment efficacy and the accuracy of report were evidenced in the current study. © 2015 American Academy of Sleep Medicine.

  15. 13C-tryptophan breath test detects increased catabolic turnover of tryptophan along the kynurenine pathway in patients with major depressive disorder

    PubMed Central

    Teraishi, Toshiya; Hori, Hiroaki; Sasayama, Daimei; Matsuo, Junko; Ogawa, Shintaro; Ota, Miho; Hattori, Kotaro; Kajiwara, Masahiro; Higuchi, Teruhiko; Kunugi, Hiroshi

    2015-01-01

    Altered tryptophan–kynurenine (KYN) metabolism has been implicated in major depressive disorder (MDD). The l-[1-13C]tryptophan breath test (13C-TBT) is a noninvasive, stable-isotope tracer method in which exhaled 13CO2 is attributable to tryptophan catabolism via the KYN pathway. We included 18 patients with MDD (DSM-IV) and 24 age- and sex-matched controls. 13C-tryptophan (150 mg) was orally administered and the 13CO2/12CO2 ratio in the breath was monitored for 180 min. The cumulative recovery rate during the 180-min test (CRR0–180; %), area under the Δ13CO2-time curve (AUC; %*min), and the maximal Δ13CO2 (Cmax; %) were significantly higher in patients with MDD than in the controls (p = 0.004, p = 0.008, and p = 0.002, respectively). Plasma tryptophan concentrations correlated negatively with Cmax in both the patients and controls (p = 0.020 and p = 0.034, respectively). Our results suggest that the 13C-TBT could be a novel biomarker for detecting a subgroup of MDD with increased tryptophan–KYN metabolism. PMID:26524975

  16. Effects of inspiratory and expiratory resistance in divers' breathing apparatus.

    PubMed

    Warkander, D E; Nagasawa, G K; Lundgren, C E

    2001-01-01

    This study was performed to determine if inspiratory breathing resistance causes greater or smaller changes than expiratory resistance. Unacceptable inspiratory resistances were also determined. Five subjects exercised at 60% of their VO2max while immersed in a hyperbaric chamber. The chamber was pressurized to either 147 kPa (1.45 atm abs, 4.5 msw, 15 fsw) or 690 kPa (6.8 atm abs, 57 msw, 190 fsw). Breathing resistance was imposed on the inspiratory or expiratory side and was as high as 0.8-1.2 kPa liter(-1) x s(-1) (8-12 cm H2O x liter(-1) x s(-1)) at a flow of 2-3 liter x s(-1) at 1 atm abs., the other side being unloaded. The subjects reacted to the imposed load by prolonging the phase of breathing that was loaded. Inspiratory breathing resistance caused greater changes than expiratory resistance in end-tidal CO2, dyspnea scores, maximum voluntary ventilation, and respiratory duty cycle. Using previously published criteria for acceptable levels of dyspnea scores and the CO2 levels, we found that an inspiratory resistance inducing a volume-averaged pressure of 1.5 kPa is not acceptable. Similarly, an expiratory resistance should not induce a volume-averaged pressure exceeding 2.0 kPa

  17. Detection of bronchial breathing caused by pneumonia.

    PubMed

    Gross, V; Fachinger, P; Penzel, Th; Koehler, U; von Wichert, P; Vogelmeier, C

    2002-06-01

    The classic auscultation with stethoscope is the established clinical method for the detection of lung diseases. The interpretation of the sounds depends on the experience of the investigating physician. Therefore, a new computer-based method has been developed to classify breath sounds from digital lung sound recordings. Lung sounds of 11 patients with one-sided pneumonia and bronchial breathing were recorded on both the pneumonia side and on contralateral healthy side simultaneously using two microphones. The spectral power for the 300-600 Hz frequency band was computed for four respiratory cycles and normalized. For each breath, the ratio R between the time-segments (duration = 0.1 s) with the highest inspiratory and highest expiratory flow was calculated and averaged. We found significant differences in R between the pneumonia side (R = 1.4 +/- 1.3) and the healthy side (R = 0.5 +/- 0.5; p = 0.003 Wilcoxon-test) of lung. In 218 healthy volunteers we found R = 0.3 +/- 0.2 as a reference-value. The differences of ratio R (delta R) between the pneumonia side and the healthy side (delta R = 1.0 +/- 0.9) were significantly higher compared to follow-up studies after recovery (delta R = 0.0 +/- 0.1, p = 0.005 Wilcoxon-test). The computer based detection of bronchial breathing can be considered useful as part of a quantitative monitoring of patients at risk to develop pneumonia.

  18. Increased breath nitrous oxide after ingesting nitrate in patients with atrophic gastritis and partial gastrectomy.

    PubMed

    Mitsui, Takahiro; Kondo, Takaharu

    2004-07-01

    Toxic nitrite and N-nitroso compounds due to gastric bacterial growth are often detected in the stomach of patients with atrophic gastritis and partial gastrectomy. The aim of this study is to investigate whether breath N2O, a major metabolite of denitrification, detected after ingestion of nitrate is associated with atrophic gastritis and partial gastrectomy. Nine young, 16 normal older, nine atrophic gastritis and six partial gastrectomy subjects ingested 100 g lettuce, equal to 130 mg nitrate, and breath N2O was measured at 15-min intervals for 5 h. N2O was analyzed using an infrared-photoacoustic analyzer, and atrophic gastritis was diagnosed by pepsinogen test. The mean breath N2O concentrations were higher in the following order at all times: partial gastrectomy>atrophic gastritis>normal>young. The maximum N2O concentrations in the patients with partial gastrectomy and atrophic gastritis were 1655 +/- 296 and 1350 +/- 200 (mean +/- S.E.) ppb, respectively, which were higher than that of the normal subjects, 827 +/- 91 ppb (P < 0.05). The maximum N2O concentration in young people was 527 +/- 86 ppb, which was lower than that of the normal older people (P < 0.051). These higher N2O concentrations in gastric patients reflect bacterial growth in the stomach due to the reduction of gastric acid. Copyright 2004 Elsevier B.V.

  19. The role of arterial chemoreceptors in the breath-by-breath augmentation of inspiratory effort in rabbits during airway occlusion or elastic loading.

    PubMed

    Callanan, D; Read, D J

    1974-08-01

    1. The breath-by-breath augmentation of inspiratory effort in the five breaths following airway occlusion or elastic loading was assessed in anaesthetized rabbits from changes of airway pressure, diaphragm e.m.g. and lung volume.2. When the airway was occluded in animals breathing air, arterial O(2) tension fell by 20 mmHg and CO(2) tension rose by 7 mmHg within the time of the first five loaded breaths.3. Inhalation of 100% O(2) or carotid denervation markedly reduced the breath-by-breath progression but had little or no effect on the responses at the first loaded breath.4. These results indicate that the breath-by-breath augmentation of inspiratory effort following addition of a load is mainly due to asphyxial stimulation of the carotid bodies, rather than to the gradual emergence of a powerful load-compensating reflex originating in the chest-wall, as postulated by some workers.5. The small residual progression seen in animals breathing 100% O(2) or following carotid denervation was not eliminated (a) by combining these procedures or (b) by addition of gas to the lungs to prevent the progressive lung deflation which occurred during airway occlusion.6. Bilateral vagotomy, when combined with carotid denervation, abolished the residual breath-by-breath progression of inspiratory effort.

  20. Estimate of production of gaseous nitrogen in the human body based on (15)N analysis of breath N2 after administration of [(15)N2]urea.

    PubMed

    Junghans, Peter

    2013-01-01

    After oral administration of [(15)N2]urea (1.5 mmol, 95 atom% (15)N), we found that breath N2 was significantly (15)N-labelled. The result suggests that molecular nitrogen in breath must be partly produced endogenously. Based on a metabolic model, the endogenous N2 production was estimated to be 0.40±0.25 mmol kg(-1) d(-1) or 2.9±1.8 % of the total (urinary and faecal) N excretion in fasted healthy subjects (n=4). In patients infected with Helicobacter pylori (n=5), the endogenous N2 production was increased to 1.24±0.59 mmol kg(-1) d(-1) or 9.0±4.3 % of the total N excretion compared to the healthy controls (p<0.05). We conclude that N balance and gas exchange measurements may be affected by endogenously produced nitrogen, especially in metabolic situations with elevated nitrosation, for instance in oxidative and nitrosative stress-related diseases such as H. pylori infections.

  1. Quiet breathing in hindlimb casted mice.

    PubMed

    Receno, Candace N; Roffo, Katelynn E; Mickey, Marisa C; DeRuisseau, Keith C; DeRuisseau, Lara R

    2018-06-07

    The hindlimb casting model was developed to study skeletal muscle reloading following a period of unloading. It is unknown if ventilation parameters of mice are affected by the casting model. We tested the hypothesis that hindlimb casted mice have similar ventilatory patterns compared to mice with the casts removed. Male CD-1 mice underwent 14 days of hindlimb immobilization via plaster casting. Breathing parameters were obtained utilizing unrestrained barometric plethysmography (UBP). Breathing traces were analyzed with Ponemah software for breathing frequency, tidal volume (TV), and minute ventilation (MV). Frequency, TV and MV did not show any differences in quiet breathing patterns during or post-casting in mice. Thus, the hindlimb casting model does not complicate breathing during and after casting and should not interfere with the unloading and reloading of skeletal muscle. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Evaluation of innovative state and community alcohol projects : breath alcohol testing program effectiveness, impact and transferability

    DOT National Transportation Integrated Search

    1987-03-01

    Breath Alcohol Testing (BAT) programs in Albuquerque and Santa Fe, New Mexico are evaluated in regard to effectiveness, impact, and transferability of the special DWI enforcement squads and their use of BAT Mobiles. Squad activity effectiveness is me...

  3. Fast-starting after a breath: air-breathing motions are kinematically similar to escape responses in the catfish Hoplosternum littorale

    PubMed Central

    Domenici, Paolo; Norin, Tommy; Bushnell, Peter G.; Johansen, Jacob L.; Skov, Peter Vilhelm; Svendsen, Morten B. S.; Steffensen, John F.; Abe, Augusto S.

    2015-01-01

    ABSTRACT Fast-starts are brief accelerations commonly observed in fish within the context of predator–prey interactions. In typical C-start escape responses, fish react to a threatening stimulus by bending their body into a C-shape during the first muscle contraction (i.e. stage 1) which provides a sudden acceleration away from the stimulus. Recently, similar C-starts have been recorded in fish aiming at a prey. Little is known about C-starts outside the context of predator–prey interactions, though recent work has shown that escape response can also be induced by high temperature. Here, we test the hypothesis that air-breathing fish may use C-starts in the context of gulping air at the surface. Hoplosternum littorale is an air-breathing freshwater catfish found in South America. Field video observations reveal that their air-breathing behaviour consists of air-gulping at the surface, followed by a fast turn which re-directs the fish towards the bottom. Using high-speed video in the laboratory, we compared the kinematics of the turn immediately following air-gulping performed by H. littorale in normoxia with those of mechanically-triggered C-start escape responses and with routine (i.e. spontaneous) turns. Our results show that air-breathing events overlap considerably with escape responses with a large stage 1 angle in terms of turning rates, distance covered and the relationship between these rates. Therefore, these two behaviours can be considered kinematically comparable, suggesting that air-breathing in this species is followed by escape-like C-start motions, presumably to minimise time at the surface and exposure to avian predators. These findings show that C-starts can occur in a variety of contexts in which fish may need to get away from areas of potential danger. PMID:25527644

  4. Analysis of Exhaled Breath for Disease Detection

    NASA Astrophysics Data System (ADS)

    Amann, Anton; Miekisch, Wolfram; Schubert, Jochen; Buszewski, Bogusław; Ligor, Tomasz; Jezierski, Tadeusz; Pleil, Joachim; Risby, Terence

    2014-06-01

    Breath analysis is a young field of research with great clinical potential. As a result of this interest, researchers have developed new analytical techniques that permit real-time analysis of exhaled breath with breath-to-breath resolution in addition to the conventional central laboratory methods using gas chromatography-mass spectrometry. Breath tests are based on endogenously produced volatiles, metabolites of ingested precursors, metabolites produced by bacteria in the gut or the airways, or volatiles appearing after environmental exposure. The composition of exhaled breath may contain valuable information for patients presenting with asthma, renal and liver diseases, lung cancer, chronic obstructive pulmonary disease, inflammatory lung disease, or metabolic disorders. In addition, oxidative stress status may be monitored via volatile products of lipid peroxidation. Measurement of enzyme activity provides phenotypic information important in personalized medicine, whereas breath measurements provide insight into perturbations of the human exposome and can be interpreted as preclinical signals of adverse outcome pathways.

  5. [Effects of breathing exercises on breathing pattern and thoracoabdominal motion after gastroplasty].

    PubMed

    Tomich, Georgia Miranda; França, Danielle Corrêa; Diniz, Marco Túlio Costa; Britto, Raquel Rodrigues; Sampaio, Rosana Ferreira; Parreira, Verônica Franco

    2010-01-01

    To evaluate breathing pattern and thoracoabdominal motion during breathing exercises. Twenty-four patients with class II or III obesity (18 women; 6 men) were studied on the second postoperative day after gastroplasty. The mean age was 37 +/- 11 years, and the mean BMI was 44 +/- 3 kg/m(2). Diaphragmatic breathing, incentive spirometry with a flow-oriented device and incentive spirometry with a volume-oriented device were performed in random order. Respiratory inductive plethysmography was used in order to measure respiratory variables and thoracoabdominal motion. Comparisons among the three exercises showed significant differences: tidal volume was higher during incentive spirometry (with the flow-oriented device or with the volume-oriented device) than during diaphragmatic breathing; the respiratory rate was lower during incentive spirometry with the volume-oriented device than during incentive spirometry with the flow-oriented device; and minute ventilation was higher during incentive spirometry (with the flow-oriented device or with the volume-oriented device) than during diaphragmatic breathing. Rib cage motion did not vary during breathing exercises, although there was an increase in thoracoabdominal asynchrony, especially during incentive spirometry with the flow-oriented device. Among the breathing exercises evaluated, incentive spirometry with the volume-oriented device provided the best results, because it allowed slower, deeper inhalation.

  6. Mosapride Accelerates the Delayed Gastric Emptying of High-Viscosity Liquids: A Crossover Study Using Continuous Real-Time 13C Breath Test (BreathID System)

    PubMed Central

    Sakamoto, Yasunari; Sekino, Yusuke; Yamada, Eiji; Ohkubo, Hidenori; Higurashi, Takuma; Sakai, Eiji; Iida, Hiroshi; Hosono, Kunihiro; Endo, Hiroki; Nonaka, Takashi; Ikeda, Tamon; Fujita, Koji; Yoneda, Masato; Koide, Tomoko; Takahashi, Hirokazu; Goto, Ayumu; Abe, Yasunobu; Gotoh, Eiji; Maeda, Shin; Nakajima, Atsushi

    2011-01-01

    Background/Aims The administration of liquid nutrients to patients is often accompanied by complications such as gastroesophageal reflux. To prevent gastroesophageal reflux, high-viscosity liquid meals are used widely, however, it still remains controversial whether high-viscosity liquid meals have any effect on the rate of gastric emptying. The present study was conducted with the aim of determining whether high-viscosity liquid meals had any effect on the rate of gastric emptying and mosapride might accelerate the rate of gastric emptying of high-viscosity liquid meals. Methods Six healthy male volunteers underwent 3 tests at intervals of > 1 week. After fasting for > 8 hours, each subject received one of three test meals (liquid meal only, high-viscosity liquid meal [liquid meal plus pectin] only, or high-viscosity liquid meal 30 minutes after intake of mosapride). A 13C-acetic acid breath test was performed, which monitored the rate of gastric emptying for 4 hours. Using the Oridion Research Software (β version), breath test parameters were calculated. The study parameters were examined for all the 3 test conditions and compared using the Freidman test. Results Gastric emptying was significantly delayed following intake of a high-viscosity liquid meal alone as compared with a liquid meal alone; however, intake of mosapride prior to a high-viscosity liquid meal was associated with a significantly accelerated rate of gastric emptying as compared with a high-viscosity liquid meal alone. Conclusions This study showed that high-viscosity liquid meals delayed gastric emptying: however, mosapride recovered the delayed rate of gastric emptying by high-viscosity liquid meals. PMID:22148109

  7. Comparison of an increased waist circumference with a positive hydrogen breath test as a clinical predictor of lactose intolerance.

    PubMed

    Zapata-Castilleja, Carlos A; Montes-Tapia, Fernando F; Treviño-Garza, Consuelo; Martínez-Cobos, María C; García-Cantú, Jesús; Arenas-Fabbri, Vincenzo; de la O-Escamilla, Norma; de la O-Cavazos, Manuel

    2017-04-01

    Lactose intolerance is a common disease in pediatrics, and its wrong diagnosis will lead to morbidity. The primary objective of this study was to assess the usefulness of an increased waist circumference during the hydrogen breath test as a predictor of lactose intolerance. The secondary objective was to analyze the impact of body mass index, waist circumference measurement, and age on the abdominal distension of patients with lactose intolerance. A total of 138 subjects aged 3 to 15 years were included. They underwent serial measurements of the waist circumference and hydrogen levels in the breath every 30 minutes over 3 hours during the hydrogen breath test. Out of the entire sample, 35 (25.4%) patients had lactose intolerance. An increase of 0.85 cm in waist circumference compared to the baseline waist circumference results in a sensitivity of 88% and a specificity of 85% to predict lactose intolerance (odds ratio: 42.14, 95% confidence interval: 13.08-135.75, p ≤ 0.001). The body mass index and waist circumference measurement did not affect abdominal distension (p= not significant); however, age modified the time of distension. A 0.85 cm increase in waist circumference compared to the baseline waist circumference during the hydrogen breath test is a useful parameter for the diagnosis of lactose intolerance in pediatrics. Variations in relation to body mass index and waist circumference did not affect the usefulness of an increased waist circumference, unlike age.

  8. Development tests of LOX/LH 2 tank for H-I launch vehicle

    NASA Astrophysics Data System (ADS)

    Takamatsu, H.; Imagawa, K.; Ichimaru, Y.

    H-I is a future launch vehicle of Japan with a capability of placing more than 550 kg payload into a geostationary orbit. The National Space Development Agency of Japan (NASDA) is now directing its efforts to the final development of H-I launch vehicle. H-I's high launch capability is attained by adopting a newly developed second stage with a LOX/LH 2 propulsion system. The second stage propulsion system consists of a tank and an engine. The tank is 2.5 m in diameter and 5.7 m in length and contains 8.7 tons of propellants. This tank is an integral tank with a common bulkhead which separates the tank into forward LH 2 tank and aft LOX tank. The tank is made of 2219 aluminum alloy and is insulated with sprayed polyurethane foam. The common bulkhead is made of FRP honeycomb core and aluminium alloy surface sheets. The most critical item in the development of the tank is the common bulkhead, therefore the cryogenic structural test was carried out to verify the structural integrity of the bulkhead. The structural integrity of the whole LOX/LH 2 tank was verified by the cryogenic structural test of a sub-scale tank and the room temperature structural test of a prototype tank.

  9. 13C-breath tests for sucrose digestion in congenital sucrase isomaltase-deficient and sacrosidase-supplemented patients

    USDA-ARS?s Scientific Manuscript database

    Congenital sucrase-isomaltase deficiency (CSID) is characterized by absence or deficiency of the mucosal sucrase-isomaltase enzyme. Specific diagnosis requires upper gastrointestinal biopsy with evidence of low to absent sucrase enzyme activity and normal histology. The hydrogen breath test (BT) is ...

  10. Adsorbent testing and mathematical modeling of a solid amine regenerative CO2 and H2O removal system

    NASA Technical Reports Server (NTRS)

    Jeng, F. F.; Williamson, R. G.; Quellette, F. A.; Edeen, M. A.; Lin, C. H.

    1991-01-01

    The paper examines the design and the construction details of the test bed built for testing a solid-amine-based Regenerable CO2 Removal System (RCRS) built at the NASA/Johnson Space Center for the extended Orbiter missions. The results of tests are presented, including those for the adsorption breakthrough and the adsorption and desorption of CO2 and H2O vapor. A model for predicting the performance of regenerative CO2 and H2O vapor adsorption of the solid amine system under various operating conditions was developed in parallel with the testing of the test stand, using the coefficient of mass transfer calculated from test results. The results of simulations are shown to predict the adsorption performance of the Extended Duration Orbiter test bed fairly well. For the application to the RCRS at various operating conditions the model has to be modified.

  11. Emptying patterns of the lung studied by multiple-breath N2 washout

    NASA Technical Reports Server (NTRS)

    Lewis, S. M.

    1978-01-01

    Changes in the nitrogen concentration seen during the single-breath nitrogen washout reflect changes in relative flow (ventilation) from units with differing ventilation/volume ratios. The multiple-breath washout provides sufficient data on ventilation for units with varying ventilation/volume ratios to be plotted as a function of the volume expired. Flow from the dead space may also be determined. In young normals the emptying patterns are narrow and unimodal throughout the alveolar plateau with little or no flow from the dead space at the end of the breath. Older normals show more flow from the dead space, particularly toward the end of the breath, and some show a high ventilation/volume ratio mode early in the breath. Patients with obstructive lung disease have a high flow from the dead space which is present throughout the breath. A well ventilated mode at the end of the breath is seen in some obstructed subjects. Patients with cystic fibrosis showed a poorly ventilated mode appearing at the end of the breath as well as a very high dead space.

  12. Exhaled breath condensate pH assays are not influenced by oral ammonia

    PubMed Central

    Wells, K; Vaughan, J; Pajewski, T; Hom, S; Ngamtrakulpanit, L; Smith, A; Nguyen, A; Turner, R; Hunt, J

    2005-01-01

    Background: Measurement of pH in exhaled breath condensate (EBC) is robust and simple. Acidic source fluid (airway lining fluid) traps bases while volatilising acids, leading to EBC acidification in many lung diseases. Lower airway ammonia is one determinant of airway lining fluid pH, raising the concern that addition of the base ammonia by contamination from the mouth might confound EBC pH assays. Methods: Three discrete methods were used to limit oral ammonia contamination of EBC collections: endotracheal intubation, oral rinsing, and –40°C condenser temperatures. Separately, ammonia was removed from collected EBC samples by lyophilisation and resuspension. Intraweek and intraday variability of ammonia concentration was determined in 76 subjects, and ammonia and pH from a further 235 samples were graphically compared. Ammonia was assayed spectrophotometrically and pH was assessed after deaeration. Results: Data from 1091 samples are presented. Ammonia was reduced in EBC by all methods. Endotracheal intubation decreased EBC ammonia from a mean (SD) of 619 (124) µM to 80 (24) µM (p<0.001, n = 32). Oral rinsing before collection also led to a decline in EBC ammonia from 573 (307) µM to 224 (80) µM (p = 0.016, n = 7). The colder the condensation temperature used, the less ammonia was trapped in the EBC. Lyophilisation removed 99.4 (1.9)% of ammonia. Most importantly, the pH of EBC never decreased after removal of ammonia by any of these methods. Intraweek and intraday coefficients of variation for ammonia were 64 (27)% and 60 (32)%, which is substantially more variable than EBC pH assays. Conclusions: Although ammonia and pH appear to correlate in EBC, the oral ammonia concentration is not an important determinant of EBC pH. No precautions need to be taken to exclude oral ammonia when EBC pH is of interest. The low pH and low ammonia found in EBC from patients with lung diseases appear to be independent effects of volatile compounds arising from the airway

  13. Tidal volume single breath washout of two tracer gases--a practical and promising lung function test.

    PubMed

    Singer, Florian; Stern, Georgette; Thamrin, Cindy; Fuchs, Oliver; Riedel, Thomas; Gustafsson, Per; Frey, Urs; Latzin, Philipp

    2011-03-10

    Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM) and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW) of sulfur hexafluoride (SF(6)) and helium (He) using an ultrasonic flowmeter (USFM). The tracer gas mixture contained 5% SF(6) and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC), were determined in seven subjects performing three SBW 24 hours apart. USFM reliably measured MM during all SBW tests (n = 60). MM from USFM reflected SF(6) and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. The USFM accurately measured relative changes in SF(6) and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF(6) and He washout patterns during tidal breathing.

  14. Tidal Volume Single Breath Washout of Two Tracer Gases - A Practical and Promising Lung Function Test

    PubMed Central

    Singer, Florian; Stern, Georgette; Thamrin, Cindy; Fuchs, Oliver; Riedel, Thomas; Gustafsson, Per; Frey, Urs; Latzin, Philipp

    2011-01-01

    Background Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM) and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW) of sulfur hexafluoride (SF6) and helium (He) using an ultrasonic flowmeter (USFM). Methods The tracer gas mixture contained 5% SF6 and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC), were determined in seven subjects performing three SBW 24 hours apart. Results USFM reliably measured MM during all SBW tests (n = 60). MM from USFM reflected SF6 and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. Conclusion The USFM accurately measured relative changes in SF6 and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF6 and He washout patterns during tidal breathing. PMID:21423739

  15. Δ(9)-Tetrahydrocannabinol concentrations in exhaled breath and physiological effects following cannabis intake - A pilot study using illicit cannabis.

    PubMed

    Coucke, Line; Massarini, Enrico; Ostijn, Zachery; Beck, Olof; Verstraete, Alain G

    2016-09-01

    Δ(9)-Tetrahydrocannabinol (THC) can be measured in exhaled breath by using an aerosol particle collection device. The sampling procedure is simple, non-invasive and takes only 2-3min. In the present study we measured the amount of THC in exhaled breath of cannabis users at specific time intervals up to 3h after smoking one cannabis cigarette. The breath concentration-effect relationship was studied by measuring the pulse rate and the pupil diameter to assess physiological changes. THC and the main metabolite 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol were analyzed in exhaled breath by a liquid chromatography-tandem mass spectrometry method. Thirteen subjects (9 males and 4 females, aged 23-24years) participated. Five of those were using cannabis more frequently than monthly. THC was detected in most subjects already at baseline, concentrations increased following smoking and remained detectable for over 3h (mean THC concentration in breath at 3h: 1479pg/sample). Pulse rate (p=0.015) and pupil diameter (p=0.044) were significantly altered up to 30min after smoking. The detection window of cannabis in breath after smoking one cannabis cigarette in occasional and chronic smokers was at least 3h. Only THC was detected, and not the metabolite. The THC concentration in exhaled breath was related to the physiological changes that occur over time. Exhaled breath can be used to detect recent cannabis exposure. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Real-time breath gas analysis of CO and CO2 using an EC-QCL

    NASA Astrophysics Data System (ADS)

    Ghorbani, Ramin; Schmidt, Florian M.

    2017-05-01

    Real-time breath gas analysis is a promising, non-invasive tool in medical diagnostics, and well-suited to investigate the physiology of carbon monoxide (CO), a potential biomarker for oxidative stress and respiratory diseases. A sensor for precise, breath-cycle resolved, simultaneous detection of exhaled CO (eCO) and carbon dioxide (eCO2) was developed based on a continuous wave, external-cavity quantum cascade laser (EC-QCL), a low-volume multi-pass cell and wavelength modulation spectroscopy. The system achieves a noise-equivalent (1σ) sensitivity of 8.5 × 10-8 cm-1 Hz-1/2 and (2σ) detection limits of 9 ± 2 ppbv and 650 ± 7 ppmv at 0.14 s spectrum acquisition time for CO and CO2, respectively. Integration over 15 s yields a precision of 0.6 ppbv for CO. The fact that the eCO2 expirograms measured by capnography and laser spectroscopy have essentially identical shape confirms true real-time detection. It is found that the individual eCO exhalation profiles from healthy non-smokers have a slightly different shape than the eCO2 profiles and exhibit a clear dependence on exhalation flow rate and breath-holding time. Detection of indoor air CO and broadband breath profiling across the 93 cm-1 mode-hop-free tuning range of the EC-QCL are also demonstrated.

  17. 49 CFR 40.243 - What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD? 40.243 Section 40.243 Transportation Office of the...-evidential breath ASD? As the BAT or STT, you must take the following steps: (a) Select, or allow the...

  18. 49 CFR 40.243 - What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What is the procedure for an alcohol screening test using an EBT or non-evidential breath ASD? 40.243 Section 40.243 Transportation Office of the...-evidential breath ASD? As the BAT or STT, you must take the following steps: (a) Select, or allow the...

  19. Breath-collection device for delayed breath-alcohol analysis

    DOT National Transportation Integrated Search

    1980-12-01

    The report includes the details of a study to develop, evaluate, and validate a breath collection device (BCD) for delayed breath-alcohol analysis. Primary applications of the BCD include collection of breath-alcohol samples for field surveys or for ...

  20. H2 fueled flightweight ramjet construction and test

    NASA Technical Reports Server (NTRS)

    Malek, Albert

    1992-01-01

    The ACES Program began the investigation of regeneratively cooled ramjet engines for propelling aircraft at Mach 6 to 8 flight regimes while collecting and processing air for later use as oxidizer in rocket propulsion into an orbit flight mode. The Marquardt Company had as its prime task the design and demonstration of a ramjet capable of steady state operating using hydrogen as the regenerative coolant and with fuel flow limited to a theta = 1. Marquardt progressed from shell type combustors to advanced tubular combustion chambers in direct connect test rigs. The first tests were made with water cooled center bodies and plug nozzles using a pebble bed air heater to simulate flight air temperature. Later tests were made on completely H2 cooled flight weight V/G assemblies direct connected to a SUE burner heater. Design studies were also conducted on integrated systems for take-off capability using offset turbojets connected to 2-D or axisymmetric inlets. An 18 inch hypersonic ramjet evaluation scale model was designed based on the hot test results using a fully V/G inlet and exit nozzle. This thruster would provide 25000 lbs. of thrust with an estimated weight of 250 lbs. A V/G inlet would also incorporate an inlet seal for possible take-off thrust by rocket operation. Hypersonic ramjet construction features and chamber thrust development are discussed.

  1. Evaluation of a rapid breath hydrogen analyzer for clinical studies of carbohydrate absorption.

    PubMed

    Solomons, N W; Hamilton, L H; Christman, N T; Rothman, D

    1983-05-01

    A second-generation gas chromatograph for the analysis of H2 in expired air has been developed. It incorporates a solid-state detector with high sensitivity for H2 and has a small, internal pump which supplies air as the carrier gas, thus eliminating the need for a large tank of compressed gas for the carrier. A reference gas of known H2 concentration is, of course, still required. The entire system weighs 6.0 kg and is completely portable, requiring only 120 V electric current for use. The instrument has a mean intersample interval of less than 2 min, with H2 concentration registered on a digital display. The output has a track-hold feature which permits the output, in parts per million H2, to be retained by the meter so the reading can be verified. The chromatogram can also be recorded on a conventional analog strip-chart recorder. The sensitivity and precision are superior to those of a thermal conductivity H2 gas chromatograph. Moreover, the rapid response time encourages frequent calibration checks with the reference gas. This analyzer offers significant advantages over previous H2-measuring systems for breath-analysis tests used both for diagnostic clinical practice and for field studies of nutritional assessment.

  2. Glucose hydrogen breath test for small intestinal bacterial overgrowth in children with abdominal pain-related functional gastrointestinal disorders.

    PubMed

    Korterink, Judith J; Benninga, Marc A; van Wering, Herbert M; Deckers-Kocken, Judith M

    2015-04-01

    A potential link between small intestinal bacterial overgrowth (SIBO) and abdominal pain-related functional gastrointestinal disorders (AP-FGID) has been suggested by symptom similarities and by the reported prevalence of SIBO in children with irritable bowel syndrome (IBS) and functional AP. The aim of this study is to evaluate the prevalence of SIBO using the glucose hydrogen breath test (GHBT), in a cohort of Dutch children with AP-FGID fulfilling the Rome III criteria, and to identify potential predictors. Children ages 6 to 18 years with AP-FGID fulfilling the Rome III criteria were included. All of the children underwent a GHBT. SIBO was diagnosed if the fasting breath hydrogen concentration was ≥20 ppm or an increase in H2 levels of ≥12 ppm above the baseline value was measured after ingestion of glucose. Gastrointestinal symptoms were collected using a standardised AP questionnaire. A total of 161 Dutch children with AP-FGID were enrolled. Twenty-three patients (14.3%) were diagnosed as having SIBO, as assessed by GHBT; 78% of the children diagnosed as having SIBO had fasting hydrogen levels ≥20 ppm. IBS was significantly more found in children with SIBO compared with children without SIBO (P = 0.001). An altered defecation pattern (ie, change in frequency or form of stool) (P = 0.013), loss of appetite (P = 0.007), and belching (P = 0.023) were significantly more found in children with SIBO compared with those without SIBO. SIBO is present in 14.3% of children presenting with AP-FGID. IBS, altered defecation pattern, loss of appetite, and belching were predictors for SIBO in children with AP-FGID.

  3. All APAPs Are Not Equivalent for the Treatment of Sleep Disordered Breathing: A Bench Evaluation of Eleven Commercially Available Devices

    PubMed Central

    Zhu, Kaixian; Roisman, Gabriel; Aouf, Sami; Escourrou, Pierre

    2015-01-01

    Study Objectives: This study challenged on a bench-test the efficacy of auto-titrating positive airway pressure (APAP) devices for obstructive sleep disordered breathing treatment and evaluated the accuracy of the device reports. Methods: Our bench consisted of an active lung simulator and a Starling resistor. Eleven commercially available APAP devices were evaluated on their reactions to single-type SDB sequences (obstructive apnea and hypopnea, central apnea, and snoring), and to a long general breathing scenario (5.75 h) simulating various SDB during four sleep cycles and to a short scenario (95 min) simulating one sleep cycle. Results: In the single-type sequence of 30-minute repetitive obstructive apneas, only 5 devices normalized the airflow (> 70% of baseline breathing amplitude). Similarly, normalized breathing was recorded with 8 devices only for a 20-min obstructive hypopnea sequence. Five devices increased the pressure in response to snoring. Only 4 devices maintained a constant minimum pressure when subjected to repeated central apneas with an open upper airway. In the long general breathing scenario, the pressure responses and the treatment efficacy differed among devices: only 5 devices obtained a residual obstructive AHI < 5/h. During the short general breathing scenario, only 2 devices reached the same treatment efficacy (p < 0.001), and 3 devices underestimated the AHI by > 10% (p < 0.001). The long scenario led to more consistent device reports. Conclusion: Large differences between APAP devices in the treatment efficacy and the accuracy of report were evidenced in the current study. Citation: Zhu K, Roisman G, Aouf S, Escourrou P. All APAPs are not equivalent for the treatment of sleep disordered breathing: a bench evaluation of eleven commercially available devices. J Clin Sleep Med 2015;11(7):725–734. PMID:25766708

  4. Psychological predictors of the antihypertensive effects of music-guided slow breathing.

    PubMed

    Modesti, Pietro Amedeo; Ferrari, Antonella; Bazzini, Cristina; Costanzo, Giusi; Simonetti, Ignazio; Taddei, Stefano; Biggeri, Annibale; Parati, Gianfranco; Gensini, Gian Franco; Sirigatti, Saulo

    2010-05-01

    The possibility that daily sessions of music-guided slow breathing may reduce 24-h ambulatory blood pressure (ABP), and predictors of efficacy were explored in a randomized, placebo-controlled trial with parallel design. Age-matched and sex-matched hypertensive patients were randomized to music-guided slow breathing exercises (4-6 breaths/min; 1: 2 ratio of inspiration: expiration duration) (Intervention; n = 29) or to control groups who were thought to relax while either listening to slow music (Control-M; n = 26) or reading a book (Control-R; n = 31). At baseline and at follow-up visits (1 week and 1, 3 and 6 months), ABP monitoring was performed. At mixed model analysis, intervention was associated with a significant reduction of 24-h (P = 0.001) and night-time (0100-0600 h) (P < 0.0001) systolic ABP. The average reduction of systolic 24-h ABP at 6 months was 4.6 mmHg [confidence limits at 95% 1.93-7.35] and 4.1 mmHg (95% confidence limits 1.59-6.67) vs. Control-M and Control-R groups, respectively, (P < 0.001 for both). Antihypertensive treatment was selected as negative predictor of BP reduction at multivariate stepwise analysis. When antihypertensive treatment was inserted as covariate in a generalized linear model, psychological subscales assessed at baseline by the Mental Health Inventory questionnaire were found to affect systolic blood pressure reduction at 6-month follow-up (general positive affect P < 0.001; emotional ties, P < 0.001; loss of behavioral control, P = 0.035). In particular, a level of general positive affect higher than the 75th percentiles was found to be significantly associated with low treatment efficacy (odds ratio 0.09; 95% confidence limits 0.01-0.93). Daily sessions of voluntary music-guided slow breathing significantly reduce 24-h systolic ABP, and psychological predictors of efficacy can be identified.

  5. Performance evaluation of the Puritan-Bennett Crew-member portable protective breathing device as prescribed by portions of FAA Action Notice A-8150.2.

    DOT National Transportation Integrated Search

    1989-05-01

    This study was undertaken, on request, to evaluate the performance of the Puritan-Bennett portable crew protective breathing device for contaminant leaks. O2, CO2 levels, inhalation/exhalation pressure, and inhalation temperature. Tests were conducte...

  6. The application of exhaled breath analysis in racing Thoroughbreds and the influence of high intensity exercise and ambient temperature on the concentration of carbon monoxide and pH in exhaled breath.

    PubMed

    Cathcart, Michael P; Love, Sandy; Sutton, David G M; Reardon, Richard J M; Hughes, Kristopher J

    2013-08-01

    Analyses of exhaled breath (EB) and exhaled breath condensate (EBC) are non-invasive modalities for assessing the lower airways but these methods have not been applied to Thoroughbred racehorses in training. The aims of this study were to determine whether EB and EBC could be obtained from Thoroughbred racehorses in the field and to investigate the effects of exercise per se and during different ambient temperatures and humidity on exhaled concentrations of nitric oxide (eNO), carbon monoxide (eCO) and EBC pH. EB and EBC samples were obtained from 28 Thoroughbred racehorses pre- and post-exercise during warm (n=23) and/or cold (n=19) ambient temperatures. eNO was detected in 19/84 EB samples. eCO was measured in 39/42 EB samples pre-exercise (median 1.3 ppm) and concentrations decreased significantly post-exercise (median 0.8 ppm, P<0.005) and were associated with ambient temperature. EBC pH was 4.51 ± 0.23 pre-exercise and increased significantly post-exercise (4.79 ± 0.59, P=0.003). The study documented the collection of EB and EBC from Thoroughbred racehorses in a field setting. Alterations in concentrations of volatile gases and EBC pH occurred in response to exercise, and were likely to have been influenced by environmental factors. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. 21 CFR 862.3080 - Breath nitric oxide test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... fractional nitric oxide concentration in expired breath aids in evaluating an asthma patient's response to anti-inflammatory therapy, as an adjunct to established clinical and laboratory assessments of asthma...

  8. PERIODIC AIR-BREATHING BEHAVIOUR IN A PRIMITIVE FISH REVEALED BY SPECTRAL ANALYSIS

    PubMed

    Hedrick; Katz; Jones

    1994-12-01

    The ventilatory patterns of air-breathing fish are commonly described as 'arrhythmic' or 'irregular' because the variable periods of breath-holding are punctuated by seemingly unpredictable air-breathing events (see Shelton et al. 1986). This apparent arrhythmicity contrasts with the perceived periodism or regularity in the gill ventilation patterns of some fish and with lung ventilation in birds and mammals. In this sense, periodism refers to behaviour that occurs with a definite, recurring interval (Bendat and Piersol, 1986). The characterisation of aerial ventilation patterns in fish as 'aperiodic' has been generally accepted on the basis of qualitative examination and it remains to be validated with rigorous testing. The bowfin, Amia calva (L.), is a primitive air-breathing fish that makes intermittent excursions to the air­water interface to gulp air, which is transferred to its well-vascularized gas bladder. Its phylogenetic position as the only extant member of the sister lineage of modern teleosts affords a unique opportunity to examine the evolution of aerial ventilation and provides a model for the examination of ventilatory patterns in primitive fishes. To establish whether Amia calva exhibit a particular pattern of air-breathing, we examined time series records of aerial ventilations from undisturbed fish over long periods (8 h). These records were the same as those used to calculate average ventilation intervals under a variety of experimental conditions (Hedrick and Jones, 1993). Their study also reported the occurrence of two distinct breath types. Type I breaths were characterised by an exhalation followed by an inhalation, whereas type II breaths were characterised by inhalation only. It was also hypothesized that the type I breaths were employed to meet oxygen demands, whereas the type II breaths were used to regulate gas bladder volume. However, they did not investigate the potential presence of a periodic ventilatory pattern. We now report

  9. Effect of alcohol consumption on the liver detoxication capacity as measured by [13C]methacetin- and [methyl-13C]methionine-breath tests.

    PubMed

    Wutzke, Klaus D; Forberger, Anke; Wigger, Marianne

    2008-06-01

    The aim of this study was to investigate the hepatic microsomal and mitochondrial functions by using the 13CO2-breath test in healthy subjects either before or after the consumption of red wine. Fourteen adults received [13C]methacetin and [methyl-13C]methionine together with a standardised dinner. Expired air samples were taken over 6 h. After a wash-out period, the subjects consumed 0.4 ml ethanol/kg/day together with dinner over a 10-day period. Thereafter, 13C-tracer administration was repeated under identical conditions. The 13CO2-enrichments were measured by isotope ratio mass spectrometry. The mean cumulative percentage 13C-dose recovery (CPDR) after administration of [13C]methacetin and [methyl-13C]methionine either without or with red wine consumption amounted to 38.2+/-6.3 vs. 36.3+/-6.7% (p=0.363) and 9.5+/-3.3 vs. 8.8+/-2.5% (p=0.47), respectively. Moderate alcohol consumption does not induce significant short-term changes of the microsomal and the mitochondrial functions of the human liver in healthy subjects.

  10. Influence of the 13C-enrichment of the habitual diet on a 13CO2 breath test used as an index of liver glycogen oxidation: a validation study in western Europe and Africa.

    PubMed

    Tanis, A A; Rietveld, T; Van den Berg, J W; Wattimena, J L; Swart, G R

    2000-01-01

    A diet containing naturally 13C-enriched carbohydrate combined with a 13CO2 breath-test analysis can be used to monitor liver glycogen oxidation in persons used to a diet low in 13C, e.g., the Western European diet. In this study, we evaluated this test principle further by changing the way we label the glycogen pool. The 13C enrichment of exhaled CO2 was studied in two groups, one in Europe and one in Africa. The European group (n = 12) was accustomed to a diet low in 13C, and they went on a 13C-enriched study diet to identify liver glycogen. The African group (n = 6) was accustomed to a diet naturally high in 13C, and they went on a diet low in 13C. The basal 13C abundance in exhaled CO2 was higher in the African group (1.0879 At%; atmospheric 1.1 atom percent) than in the European group (1.0821 At%). During the study period, the parameters for liver glycogen oxidation--the 13CO2 enrichment plateau, the plateau duration, and the return to baseline time--did not differ between groups. The abundance of 13CO2 in exhaled CO2 over time in the two groups was similar but inverse. This study confirms the use of a 13CO2 breath test to monitor liver glycogen oxidation and demonstrates how to use such a test in persons accustomed to a diet high in 13C.

  11. Dynamic model inversion techniques for breath-by-breath measurement of carbon dioxide from low bandwidth sensors.

    PubMed

    Sivaramakrishnan, Shyam; Rajamani, Rajesh; Johnson, Bruce D

    2009-01-01

    Respiratory CO(2) measurement (capnography) is an important diagnosis tool that lacks inexpensive and wearable sensors. This paper develops techniques to enable use of inexpensive but slow CO(2) sensors for breath-by-breath tracking of CO(2) concentration. This is achieved by mathematically modeling the dynamic response and using model-inversion techniques to predict input CO(2) concentration from the slow-varying output. Experiments are designed to identify model-dynamics and extract relevant model-parameters for a solidstate room monitoring CO(2) sensor. A second-order model that accounts for flow through the sensor's filter and casing is found to be accurate in describing the sensor's slow response. The resulting estimate is compared with a standard-of-care respiratory CO(2) analyzer and shown to effectively track variation in breath-by-breath CO(2) concentration. This methodology is potentially useful for measuring fast-varying inputs to any slow sensor.

  12. How to breathe when you are short of breath

    MedlinePlus

    ... pursed lip breathing; Hypoxia - pursed lip breathing; Chronic respiratory failure - pursed lip breathing ... et al, eds. Murray and Nadel's Textbook of Respiratory Medicine . 6th ed. Philadelphia, PA: Elsevier Saunders; 2016: ...

  13. TH-CD-202-09: Free-Breathing Proton MRI Functional Lung Avoidance Maps to Guide Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Capaldi, D; Sheikh, K; Parraga, G

    Purpose: Pulmonary functional MRI using inhaled gas contrast agents was previously investigated as a way to identify well-functioning lung in patients with NSCLC who are clinical candidates for radiotherapy. Hyperpolarized noble-gas ({sup 3}He and {sup 129}Xe) MRI has also been optimized to measure functional lung information, but for a number of reasons, the clinical translation of this approach to guide radiotherapy planning has been limited. As an alternative, free-breathing pulmonary 1H MRI using clinically available MRI systems and pulse sequences provides a non-contrast-enhanced method to generate both ventilation and perfusion maps. Free-breathing {sup 1}H MRI exploits non-rigid registration and Fouriermore » decomposition of MRI signal intensity differences (Bauman et al., MRM, 2009) that may be generated during normal tidal breathing. Here, our objective was to generate free-breathing {sup 1}H MRI ventilation and lung function avoidance maps in patients with NSCLC as a way to guide radiation therapy planning. Methods: Stage IIIA/IIIB NSCLC patients (n=8, 68±9yr) provided written informed consent to a randomized controlled clinical trial ( https://clinicaltrials.gov/ct2/show/NCT02002052 ) that aimed to compare outcomes related to image-guided versus conventional radiation therapy planning. Hyperpolarized {sup 3}He/{sup 129}Xe and dynamic free tidal-breathing {sup 1}H MRI were acquired as previously described (Capaldi et al., Acad Radiol, 2015). Non-rigid registration was performed using the modality-independent-neighbourhood-descriptor (MIND) deformable approach (Heinrich et al., Med Image Anal, 2012). Ventilation-defect-percent ({sup 3}He:VDP{sub He}, {sup 129}Xe:VDP{sub Xe}, Free-breathing-{sup 1}H:VDP{sub FB}) and the corresponding ventilation maps were compared using Pearson correlation coefficients (r) and the Dice similarity coefficient (DSC). Results: VDP{sub FB} was significantly related to VDP{sub He} (r=.71; p=.04) and VDP{sub Xe} (r=.80; p=.01

  14. Unilateral ablation of pre-Botzinger complex disrupts breathing during sleep but not wakefulness.

    PubMed

    McKay, Leanne C; Feldman, Jack L

    2008-07-01

    In adult rats, bilateral ablation of pre-Bötzinger complex (preBötC) neurokinin 1-expressing (NK1R) neurons leads to a progressive and irreversible disruption in breathing pattern, initially during sleep, eventually resulting in an ataxic breathing pattern during wakefulness. Here we determine whether ablation of fewer preBötC NK1R neurons leads to a persistent pattern of disordered breathing during sleep but not during wakefulness. Adult male Sprague-Dawley rats (n = 12) were instrumented to record diaphragmatic, abdominal, and neck EMG, and EEG. Fourteen days later, a second surgery was performed to stereotaxically microinject into the preBötC on one side the toxin saporin conjugated to substance P (SP-SAP), which selectively ablates NK1R neurons. Postinjection, rats were monitored within a plethysmograph until they were killed (Days 21-51). At Days 6-9 post-unilateral SP-SAP injection, respiratory pattern during sleep, particularly REM sleep, became increasingly disordered, characterized by an increase in frequency of central sleep apnea and hypopneas (36.8 +/- 7.4 episodes/h of REM vs. 6 +/- 2.0 episodes/h in preinjection controls; P < 0.05), whereas breathing during resting wakefulness remained stable. Unlike bilateral SP-SAP-injected rats, an ataxic breathing pattern did not develop during wakefulness. Rats that were monitored up to 51 days post-SP-SAP injection continued to have sleep-disordered breathing; breathing during wakefulness remained relatively stable. Histologic analysis of the ventrolateral medulla confirmed that NK1R neurons within the preBötC on the injected but not on the contralateral side of the medulla were ablated. Gradual loss of preBötC NK1R neurons may be an underlying factor of sleep-disordered breathing, in particular of central sleep apnea.

  15. How Important Is a Reproducible Breath Hold for Deep Inspiration Breath Hold Breast Radiation Therapy?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiant, David, E-mail: David.wiant@conehealth.com; Wentworth, Stacy; Liu, Han

    Purpose: Deep inspiration breath hold (DIBH) for left-sided breast cancer has been shown to reduce heart dose. Surface imaging helps to ensure accurate breast positioning, but it does not guarantee a reproducible breath hold (BH) at DIBH treatments. We examine the effects of variable BH positions for DIBH treatments. Methods and Materials: Twenty-five patients who underwent free breathing (FB) and DIBH scans were reviewed. Four plans were created for each patient: FB, DIBH, FB-DIBH (the DIBH plans were copied to the FB images and recalculated, and image registration was based on breast tissue), and P-DIBH (a partial BH with themore » heart shifted midway between the FB and DIBH positions). The FB-DIBH plans give a “worst-case” scenario for surface imaging DIBH, where the breast is aligned by surface imaging but the patient is not holding their breath. Kolmogorov-Smirnov tests were used to compare the dose metrics. Results: The DIBH plans gave lower heart dose and comparable breast coverage versus FB in all cases. The FB-DIBH plans showed no significant difference versus FB plans for breast coverage, mean heart dose, or maximum heart dose (P≥.10). The mean heart dose differed between FB-DIBH and FB by <2 Gy for all cases, and the maximum heart dose differed by <2 Gy for 21 cases. The P-DIBH plans showed significantly lower mean heart dose than FB (P<.01). The mean heart doses for the P-DIBH plans were« less

  16. Comparison of ethanol concentrations in venous blood and end-expired breath during a controlled drinking study.

    PubMed

    Jones, A W; Andersson, L

    2003-03-12

    Concentration-time profiles of ethanol were determined for venous whole blood and end-expired breath during a controlled drinking experiment in which healthy men (n=9) and women (n=9) drank 0.40-0.65 g ethanol per kg body weight in 20-30 min. Specimens of blood and breath were obtained for analysis of ethanol starting at 50-60 min post-dosing and then every 30-60 min for 3-6 h. This protocol furnished 130 blood-breath pairs for statistical evaluation. Blood-ethanol concentration (BAC, mg/g) was determined by headspace gas chromatography and breath-ethanol concentration (BrAC, mg/2l) was determined with a quantitative infrared analyzer (Intoxilyzer 5000S), which is the instrument currently used in Sweden for legal purposes. In 18 instances the Intoxilyzer 5000S gave readings of 0.00 mg/2l whereas the actual BAC was 0.08 mg/g on average (range 0.04-0.15 mg/g). The remaining 112 blood- and breath-alcohol measurements were highly correlated (r=0.97) and the regression relationship was BAC=0.10+0.91BrAC and the residual standard deviation (S.D.) was 0.042 mg/g (8.4%). The slope (0.91+/-0.0217) differed significantly from unity being 9% low and the intercept (0.10+/-0.0101) deviated from zero (t=10.2, P<0.001), indicating the presence of both proportional and constant bias, respectively. The mean bias (BAC - BrAC) was 0.068 mg/g and the 95% limits of agreement were -0.021 and 0.156 mg/g. The average BAC/BrAC ratio was 2448+/-540 (+/-S.D.) with a median of 2351 and 2.5th and 97.5th percentiles of 1836 and 4082. We found no significant gender-related differences in BAC/BrAC ratios, being 2553+/-576 for men and 2417+/-494 for women (t=1.34, P>0.05). The mean rate of ethanol disappearance from blood was 0.157+/-0.021 mg/(g per hour), which was very close to the elimination rate from breath of 0.161+/-0.021 mg/(2l per hour) (P>0.05). Breath-test results obtained with Intoxilyzer 5000S (mg/2l) were generally less than the coexisting concentrations of ethanol in venous blood

  17. Optimising diffusion-weighted MR imaging for demonstrating pancreatic cancer: a comparison of respiratory-triggered, free-breathing and breath-hold techniques.

    PubMed

    Kartalis, Nikolaos; Loizou, Louiza; Edsborg, Nick; Segersvärd, Ralf; Albiin, Nils

    2012-10-01

    To compare respiratory-triggered, free-breathing, and breath-hold DWI techniques regarding (1) image quality, and (2) signal intensity (SI) and ADC measurements in pancreatic ductal adenocarcinoma (PDAC). Fifteen patients with histopathologically proven PDAC underwent DWI prospectively at 1.5 T (b = 0, 50, 300, 600 and 1,000 s/mm(2)) with the three techniques. Two radiologists, independently and blindly, assigned total image quality scores [sum of rating diffusion images (lesion detection, anatomy, presence of artefacts) and ADC maps (lesion characterisation, overall image quality)] per technique and ranked them. The lesion SI, signal-to-noise ratio, mean ADC and coefficient of variation (CV) were compared. Total image quality scores for respiratory-triggered, free-breathing and breath-hold techniques were 17.9, 16.5 and 17.1 respectively (respiratory-triggered was significantly higher than free-breathing but not breath-hold). The respiratory-triggered technique had a significantly higher ranking. Lesion SI on all b-values and signal-to-noise ratio on b300 and b600 were significantly higher for the respiratory-triggered technique. For respiratory-triggered, free-breathing and breath-hold techniques the mean ADCs were 1.201, 1.132 and 1.253 × 10(-3) mm(2)/s, and mean CVs were 8.9, 10.8 and 14.1 % respectively (respiratory-triggered and free-breathing techniques had a significantly lower mean CV than the breath-hold technique). In both analyses, respiratory-triggered DWI showed superiority and seems the optimal DWI technique for demonstrating PDAC. • Diffusion-weighted magnetic resonance imaging is increasingly used to detect pancreatic cancer • Images are acquired using various breathing techniques and multiple b-values • Breathing techniques used: respiratory-triggering, free-breathing and breath-hold • Respiratory-triggering seems the optimal breathing technique for demonstrating pancreatic cancer.

  18. 46 CFR 197.456 - Breathing supply hoses.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Breathing supply hoses. 197.456 Section 197.456 Shipping....456 Breathing supply hoses. (a) The diving supervisor shall insure that— (1) Each breathing supply....5 times its maximum working pressure; (2) Each breathing supply hose assembly, prior to being placed...

  19. Oxygen-18 isotope of breath CO2 linking to erythrocytes carbonic anhydrase activity: a biomarker for pre-diabetes and type 2 diabetes

    PubMed Central

    Ghosh, Chiranjit; Banik, Gourab D.; Maity, Abhijit; Som, Suman; Chakraborty, Arpita; Selvan, Chitra; Ghosh, Shibendu; Chowdhury, Subhankar; Pradhan, Manik

    2015-01-01

    Carbonic anhydrase (CA), a well-characterized metalloenzyme, is associated with oxygen-18 ( 18O)-isotopic fractionations of CO2. To investigate how CA activity links the 18O of breath CO2 to pre-diabetes (PD) and type 2 diabetes (T2D) during metabolism, we studied pre- and post-dose CA activities in erythrocytes with simultaneous monitoring of 18O/ 16O-isotope ratios of breath CO2 and thereafter elucidated potential metabolic pathways underlying CA alteration in the pathogenesis of T2D. Here we show that the post-dose CA activity in both T2D and PD was markedly enhanced, whereas the non-diabetic controls (NDC) exhibited a considerable reduction in post-dose CA activity when compared with their basal CA activities. However, T2D and PD exhibited isotopic enrichments of 18O in breath CO2, while a marked depletion of 18O in CO2 was manifested in NDC. Thus, the isotopic enrichments and depletions of 18O in breath CO2 were well correlated with the changes in CA activities for controls, PD and T2D. Our findings suggest the changes in CA activities in erythrocytes may contribute to the pathogenesis of T2D and the breath C 18O 16O regulated by the CA activity as a potential biomarker for non-invasive assessment of T2D, and thus may open a new method for treating T2D. PMID:25633556

  20. Afternoon serum-melatonin in sleep disordered breathing.

    PubMed

    Ulfberg, J; Micic, S; Strøm, J

    1998-08-01

    To study afternoon serum-melatonin values in patients with sleep disordered breathing. Melatonin has a strong circadian rhythm with high values during the night-time and low values in the afternoon. Sleep disordered breathing may change the circadian rhythm of melatonin which may have diagnostic implications. The Sleep Laboratory, The Department of Internal Medicine, Avesta Hospital, Sweden, and the Department of Anaesthesiology, Glostrup University Hospital, Copenhagen, Denmark. We examined 60 consecutive patients admitted for sleep disordered breathing and 10 healthy non snoring controls. The patients underwent a sleep apnoea screening test having a specificity of 100% for the obstructive sleep apnoea syndrome (OSAS) using a combination of static charge sensitive bed and oximetry. Obstructive sleep apnoea syndrome was found in 49 patients, eight patients had borderline sleep disordered breathing (BSDB) and three patients were excluded due to interfering disease. Patients and controls had an afternoon determination of serum-melatonin. The Epworth Sleepiness Scale was used to score day-time sleepiness. In comparison with normal controls patients suffering from OSAS had significantly higher serum-melatonin levels in the afternoon. However, as a diagnostic test for OSAS in patients with sleep disordered breathing serum-melatonin showed a low sensitivity but a high specificity. The results indicate that breathing disorders during sleep in general affect pineal function. Sleep disordered breathing seems to disturb pineal function. Determination of afternoon serum-melatonin alone or together with a scoring of daytime sleepiness does not identify OSAS-patients in a heterogeneous population of patients complaining of heavy snoring and excessive daytime sleepiness.

  1. Postural Change Alters Autonomic Responses to Breath-Holding

    PubMed Central

    Taneja, Indu; Medow, Marvin S.; Clarke, Debbie; Ocon, Anthony; Stewart, Julian M.

    2011-01-01

    We used breath-holding during inspiration as a model to study the effect of pulmonary stretch on sympathetic nerve activity. Twelve healthy subjects (7 females, 5 males; 19–27 yrs) were tested while they performed an inspiratory breath-hold, both supine and during a 60° head-up tilt (HUT 60). Heart rate (HR), mean arterial blood pressure (MAP), respiration, muscle sympathetic nerve activity (MSNA), oxygen saturation (SaO2) and end tidal carbon dioxide (ETCO2) were recorded. Cardiac output (CO) and total peripheral resistance (TPR) were calculated. While breath-holding, ETCO2 increased significantly from 41±2 to 60±2 Torr during supine (p<0.05) and 38±2 Torr to 58±2 during HUT60 (p<0.05); SaO2 decreased from 98±1.5% to 95±1.4% supine, and from 97±1.5% to 94±1.7% during HUT60 (p=NS). MSNA showed three distinctive phases - a quiescent phase due to pulmonary stretch associated with decreased MAP, HR, CO and TPR; a second phase of baroreflex-mediated elevated MSNA which was associated with recovery of MAP and HR only during HUT60; CO and peripheral resistance returned to baseline while supine and HUT60; a third phase of further increased MSNA activity related to hypercapnia and associated with increased TPR. Breath-holding results in initial reductions of MSNA, MAP and HR by the pulmonary stretch reflex followed by increased sympathetic activity related to the arterial baroreflex and chemoreflex. PMID:20012144

  2. A novel visually CO2 controlled alveolar breath sampling technique.

    PubMed

    Birken, Thomas; Schubert, Jochen; Miekisch, Wolfram; Nöldge-Schomburg, Gabriele

    2006-01-01

    A crucial issue in the analysis of exhaled breath is the collection of gaseous samples. The analysis of pure alveolar gas is the method of choice if contamination of samples is to be minimized. Monitoring of expired CO2 can be used to identify alveolar gas. The purpose of this study was to evaluate a bed side version of this technique using visual CO2 control by means of a capnometer. 22 mechanically ventilated patients of an ICU were enrolled into the study. Alveolar and mixed expiratory gas, and arterial blood were sampled. PCO2 in blood and gas was determined in a blood gas analyzer. End tidal PCO2 was monitored in all patients by a fast responding main stream capnometry. Taking the gaseous samples was visually synchronized with the expired CO2. Alveolar CO2 contents measured during two different respiratory cycles were identical (p 0.86). The variation of the CO2 content during 10 measurements in one patient was lower than 4%. Arterial PCO2, PCO2 in alveolar gas and end tidal PCO2 showed positive correlation. The visually CO2-controlled sampling technique of alveolar gas is a reliable and reproducible method. It represents an important step in simplifying and standardizing breath analysis.

  3. Breath analysis in disease diagnosis: methodological considerations and applications.

    PubMed

    Lourenço, Célia; Turner, Claire

    2014-06-20

    Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. "Breath fingerprinting", indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles.

  4. Microgravity reduces sleep-disordered breathing in humans.

    PubMed

    Elliott, A R; Shea, S A; Dijk, D J; Wyatt, J K; Riel, E; Neri, D F; Czeisler, C A; West, J B; Prisk, G K

    2001-08-01

    To understand the factors that alter sleep quality in space, we studied the effect of spaceflight on sleep-disordered breathing. We analyzed 77 8-h, full polysomnographic recordings (PSGs) from five healthy subjects before spaceflight, on four occasions per subject during either a 16- or 9-d space shuttle mission and shortly after return to earth. Microgravity was associated with a 55% reduction in the apnea-hypopnea index (AHI), which decreased from a preflight value of 8.3 +/- 1.6 to 3.4 +/- 0.8 events/h inflight. This reduction in AHI was accompanied by a virtual elimination of snoring, which fell from 16.5 +/- 3.0% of total sleep time preflight to 0.7 +/- 0.5% inflight. Electroencephalogram (EEG) arousals also decreased in microgravity (by 19%), and this decrease was almost entirely a consequence of the reduction in respiratory-related arousals, which fell from 5.5 +/- 1.2 arousals/h preflight to 1.8 +/- 0.6 inflight. Postflight there was a return to near or slightly above preflight levels in these variables. We conclude that sleep quality during spaceflight is not degraded by sleep-disordered breathing. This is the first direct demonstration that gravity plays a dominant role in the generation of apneas, hypopneas, and snoring in healthy subjects.

  5. Microgravity reduces sleep-disordered breathing in humans

    NASA Technical Reports Server (NTRS)

    Elliott, A. R.; Shea, S. A.; Dijk, D. J.; Wyatt, J. K.; Riel, E.; Neri, D. F.; Czeisler, C. A.; West, J. B.; Prisk, G. K.

    2001-01-01

    To understand the factors that alter sleep quality in space, we studied the effect of spaceflight on sleep-disordered breathing. We analyzed 77 8-h, full polysomnographic recordings (PSGs) from five healthy subjects before spaceflight, on four occasions per subject during either a 16- or 9-d space shuttle mission and shortly after return to earth. Microgravity was associated with a 55% reduction in the apnea-hypopnea index (AHI), which decreased from a preflight value of 8.3 +/- 1.6 to 3.4 +/- 0.8 events/h inflight. This reduction in AHI was accompanied by a virtual elimination of snoring, which fell from 16.5 +/- 3.0% of total sleep time preflight to 0.7 +/- 0.5% inflight. Electroencephalogram (EEG) arousals also decreased in microgravity (by 19%), and this decrease was almost entirely a consequence of the reduction in respiratory-related arousals, which fell from 5.5 +/- 1.2 arousals/h preflight to 1.8 +/- 0.6 inflight. Postflight there was a return to near or slightly above preflight levels in these variables. We conclude that sleep quality during spaceflight is not degraded by sleep-disordered breathing. This is the first direct demonstration that gravity plays a dominant role in the generation of apneas, hypopneas, and snoring in healthy subjects.

  6. Tracking performance with two breathing oxygen concentrations after high altitude rapid decompression

    NASA Technical Reports Server (NTRS)

    Nesthus, Thomas E.; Schiflett, Samuel G.; Oakley, Carolyn J.

    1992-01-01

    Current military aircraft Liquid Oxygen (LOX) systems supply 99.5 pct. gaseous Aviator's Breathing Oxygen (ABO) to aircrew. Newer Molecular Sieve Oxygen Generation Systems (MSOGS) supply breathing gas concentration of 93 to 95 pct. O2. The margin is compared of hypoxia protection afforded by ABO and MSOGS breathing gas after a 5 psi differential rapid decompression (RD) in a hypobaric research chamber. The barometric pressures equivalent to the altitudes of 46000, 52000, 56000, and 60000 ft were achieved from respective base altitudes in 1 to 1.5 s decompressions. During each exposure, subjects remained at the simulated peak altitude breathing either 100 or 94 pct. O2 with positive pressure for 60 s, followed by a rapid descent to 40000 ft. Subjects used the Tactical Life Support System (TLSS) for high altitude protection. Subcritical tracking task performance on the Performance Evaluation Device (PED) provided psychomotor test measures. Overall tracking task performance results showed no differences between the MSOGS breathing O2 concentration of 94 pct. and ABO. Significance RMS error differences were found between the ground level and base altitude trials compared to peak altitude trials. The high positive breathing pressures occurring at the peak altitudes explained the differences.

  7. Do elite breath-hold divers suffer from mild short-term memory impairments?

    PubMed

    Billaut, François; Gueit, Patrice; Faure, Sylvane; Costalat, Guillaume; Lemaître, Frédéric

    2018-03-01

    Repeated apneas are associated with severe hypoxemia that may ultimately lead to loss of consciousness in some breath-hold divers. Despite increasing number of practitioners, the relationship between apnea-induced hypoxia and neurocognitive functions is still poorly understood in the sport of free diving. To shed light onto this phenomenon, we examined the impact of long-term breath-hold diving training on attentional processing, short-term memory, and long-term mnesic and executive functions. Thirty-six men matched for age, height, and weight were separated into the following 3 groups: (i) 12 elite breath-hold divers (EBHD), mean static apnea best time 371 s, 105 months mean apnea experience; (ii) 12 novice breath-hold divers, mean best time 243 s, 8.75 months mean apnea experience; and (iii) 12 physical education students with no breath-hold diving experience; all of these participants performed varied written and computerized neuropsychological tasks. Compared with the 2 other groups, the EBHD group was slower to complete the interference card during a Stroop test (F [1,33] = 4.70, p < 0.05), and presented more errors on the interference card (F [1,33] = 2.96, p < 0.05) and a lower total interference score (F [1,33] = 5.64, p < 0.05). The time to complete the interference card test was positively correlated with maximal static apnea duration (r = 0.73, p < 0.05) and the number of years of breath-hold diving training (r = 0.79, p < 0.001). These findings suggest that breath-hold diving training over several years may cause mild, but persistent, short-term memory impairments.

  8. A dual mode breath sampler for the collection of the end-tidal and dead space fractions.

    PubMed

    Salvo, P; Ferrari, C; Persia, R; Ghimenti, S; Lomonaco, T; Bellagambi, F; Di Francesco, F

    2015-06-01

    This work presents a breath sampler prototype automatically collecting end-tidal (single and multiple breaths) or dead space air fractions (multiple breaths). This result is achieved by real time measurements of the CO2 partial pressure and airflow during the expiratory and inspiratory phases. Suitable algorithms, used to control a solenoid valve, guarantee that a Nalophan(®) bag is filled with the selected breath fraction even if the subject under test hyperventilates. The breath sampler has low pressure drop (<0.5 kPa) and uses inert or disposable components to avoid bacteriological risk for the patients and contamination of the breath samples. A fully customisable software interface allows a real time control of the hardware and software status. The performances of the breath sampler were evaluated by comparing (a) the CO2 partial pressure calculated during the sampling with the CO2 pressure measured off-line within the Nalophan(®) bag; (b) the concentrations of four selected volatile organic compounds in dead space, end-tidal and mixed breath fractions. Results showed negligible deviations between calculated and off-line CO2 pressure values and the distributions of the selected compounds into dead space, end-tidal and mixed breath fractions were in agreement with their chemical-physical properties. Copyright © 2015. Published by Elsevier Ltd.

  9. Endogenous CO dynamics monitoring in breath by tunable diode laser

    NASA Astrophysics Data System (ADS)

    Kouznetsov, Andrian I.; Stepanov, Eugene V.; Shulagin, Yurii A.; Skrupskii, Vladimir A.

    1996-04-01

    High sensitive CO gas analyzer based on tunable diode laser (TDL) was used as a real time monitor of endogenous carbon monoxide in a set of breath physiology experiments. The measurements of the CO content dynamics in exhaled air with 10 ppb sensitivity were attended with detection of carbon dioxide and O2 in breath, lung ventilation parameters, heart rate and blood analysis using conventional techniques. Variations of endogenous CO in human breath caused by hyperoxia, hypoxia, hyperventilation as well as sport loading were studied in real time. Scattering of the CO variation time constants was observed for different tested persons. Possible reasons for this scattering related with the organisms' physiology peculiarities are discussed.

  10. Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

    PubMed

    Loeffler, Ralf B; McCarville, M Beth; Wagstaff, Anne W; Smeltzer, Matthew P; Krafft, Axel J; Song, Ruitian; Hankins, Jane S; Hillenbrand, Claudia M

    2017-01-01

    Liver R2* values calculated from multi-gradient echo (mGRE) magnetic resonance images (MRI) are strongly correlated with hepatic iron concentration (HIC) as shown in several independently derived biopsy calibration studies. These calibrations were established for axial single-slice breath-hold imaging at the location of the portal vein. Scanning in multi-slice mode makes the exam more efficient, since whole-liver coverage can be achieved with two breath-holds and the optimal slice can be selected afterward. Navigator echoes remove the need for breath-holds and allow use in sedated patients. To evaluate if the existing biopsy calibrations can be applied to multi-slice and navigator-controlled mGRE imaging in children with hepatic iron overload, by testing if there is a bias-free correlation between single-slice R2* and multi-slice or multi-slice navigator controlled R2*. This study included MRI data from 71 patients with transfusional iron overload, who received an MRI exam to estimate HIC using gradient echo sequences. Patient scans contained 2 or 3 of the following imaging methods used for analysis: single-slice images (n = 71), multi-slice images (n = 69) and navigator-controlled images (n = 17). Small and large blood corrected region of interests were selected on axial images of the liver to obtain R2* values for all data sets. Bland-Altman and linear regression analysis were used to compare R2* values from single-slice images to those of multi-slice images and navigator-controlled images. Bland-Altman analysis showed that all imaging method comparisons were strongly associated with each other and had high correlation coefficients (0.98 ≤ r ≤ 1.00) with P-values ≤0.0001. Linear regression yielded slopes that were close to 1. We found that navigator-gated or breath-held multi-slice R2* MRI for HIC determination measures R2* values comparable to the biopsy-validated single-slice, single breath-hold scan. We conclude that these three R2

  11. High-pitched breath sounds indicate airflow limitation in asymptomatic asthmatic children.

    PubMed

    Habukawa, Chizu; Nagasaka, Yukio; Murakami, Katsumi; Takemura, Tsukasa

    2009-04-01

    Asthmatic children may have airway dysfunction even when asymptomatic, indicating that their long-term treatment is less than optimal. Although airway dysfunction can be identified on lung function testing, performing these tests can be difficult in infants. We studied whether breath sounds reflect subtle airway dysfunction in asthmatic children. The highest frequency of inspiratory breaths sounds (HFI) and the highest frequency of expiratory breath sounds (HFE) were measured in 131 asthmatic children while asymptomatic and with no wheezes for more than 2 weeks. No child was being treated with inhaled corticosteroids (ICS). Breath sounds were recorded and analysed by sound spectrography and compared with spirometric parameters. After initial evaluation, cases with more than step 2 (mild persistent) asthma were treated using inhaled fluticasone (100-200 microg/day) for 1 month, and then breath sound analysis and pulmonary function testing were repeated. On initial evaluation, HFI correlated with the percentage of predicted FEF(50) (%FEF(50)), (r = -0.45, P < 0.001), the percentage of predicted FEF(75) (%FEF(75)) (r = -0.456, P < 0.001), and FEV(1) as a percentage of FVC (FEV(1)/FVC (%)) (r = -0.32, P < 0.001). HFI did not correlate with the percentage of predicted PEF (%PEF). The 69 children with lower than normal %FEF(50) were then treated with ICS. The %FEF(50) and %FEF(75) improved after ICS treatment, and increases in %FEF(50) (P < 0.005) correlated with decreases in HFI (P < 0.001). Higher HFI in asymptomatic asthmatic children may indicate small airway obstruction. Additional ICS treatment may improve the pulmonary function indices representing small airway function with simultaneous HFI decreases in such patients.

  12. Variability in the blood/breath alcohol ratio and implications for evidentiary purposes.

    PubMed

    Jaffe, Dena H; Siman-Tov, Maya; Gopher, Asher; Peleg, Kobi

    2013-09-01

    The breath analyzer is an indispensable tool for identifying alcohol levels among drivers. While numerous studies have shown high correlations between blood and breath alcohol concentrations, most are limited by the study design. This study seeks to assess this relationship by minimizing potential measurement bias, document time from alcohol consumption to testing, and adjusting for potential confounders. A blinded study was performed using conditions closely resembling those in the field. The Draeger 7110 MKIII IL breath analyzer was used to assess breath alcohol concentrations (BrAC). Participants were 61 healthy volunteers aged 21-37 years with body mass index ≤30 and no history of alcoholism. A total of 242 valid blood/breath tests were performed in four test sets. The study results showed a high correlation coefficient between BrAC and blood alcohol concentration (BAC) levels (r = 0.983) with high sensitivity (97%) and specificity (93%). This strong association between the breath analyzer and BAC persisted even after adjustment for various stages of alcohol absorption. These results illustrate the high diagnostic sensitivity of the breath analyzer in field-tested conditions. © 2013 American Academy of Forensic Sciences.

  13. The role of size in synchronous air breathing of Hoplosternum littorale.

    PubMed

    Sloman, Katherine A; Sloman, Richard D; De Boeck, Gudrun; Scott, Graham R; Iftikar, Fathima I; Wood, Chris M; Almeida-Val, Vera M F; Val, Adalberto L

    2009-01-01

    Synchronized air breathing may have evolved as a way of minimizing the predation risk known to be associated with air breathing in fish. Little is known about how the size of individuals affects synchronized air breathing and whether some individuals are required to surface earlier than necessary in support of conspecifics, while others delay air intake. Here, the air-breathing behavior of Hoplosternum littorale held in groups or in isolation was investigated in relation to body mass, oxygen tensions, and a variety of other physiological parameters (plasma lactate, hepatic glycogen, hematocrit, hemoglobin, and size of heart, branchial basket, liver, and air-breathing organ [ABO]). A mass-specific relationship with oxygen tension of first surfacing was seen when fish were held in isolation; smaller individuals surfaced at higher oxygen tensions. However, this relationship was lost when the same individuals were held in social groups of four, where synchronous air breathing was observed. In isolation, 62% of fish first surfaced at an oxygen tension lower than the calculated P(crit) (8.13 kPa), but in the group environment this was reduced to 38% of individuals. Higher oxygen tensions at first surfacing in the group environment were related to higher levels of activity rather than any of the physiological parameters measured. In fish held in isolation but denied access to the water surface for 12 h before behavioral testing, there was no mass-specific relationship with oxygen tension at first surfacing. Larger individuals with a greater capacity to store air in their ABOs may, therefore, remain in hypoxic waters for longer periods than smaller individuals when held in isolation unless prior access to the air is prevented. This study highlights how social interaction can affect air-breathing behaviors and the importance of considering both behavioral and physiological responses of fish to hypoxia to understand the survival mechanisms they employ.

  14. Evaluation of the Scott Aviation Portable Protective Breathing Device for contaminant leakage as prescribed by FAA Action Notice A-8150.2.

    DOT National Transportation Integrated Search

    1989-11-01

    Two types of crewmember protective breathing equipment (PBE) were performance tested for compliance with Action Notice A-8150.2 at ground level (- 1,300 feet) and 8,000 feet altitude. PBE 1 was a 'hood with oral-nasal mask,' which used potassium supe...

  15. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...

  16. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...

  17. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...

  18. Deodorization of garlic breath volatiles by food and food components.

    PubMed

    Munch, Ryan; Barringer, Sheryl A

    2014-04-01

    The ability of foods and beverages to reduce allyl methyl disulfide, diallyl disulfide, allyl mercaptan, and allyl methyl sulfide on human breath after consumption of raw garlic was examined. The treatments were consumed immediately following raw garlic consumption for breath measurements, or were blended with garlic prior to headspace measurements. Measurements were done using a selected ion flow tube-mass spectrometer. Chlorophyllin treatment demonstrated no deodorization in comparison to the control. Successful treatments may be due to enzymatic, polyphenolic, or acid deodorization. Enzymatic deodorization involved oxidation of polyphenolic compounds by enzymes, with the oxidized polyphenols causing deodorization. This was the probable mechanism in raw apple, parsley, spinach, and mint treatments. Polyphenolic deodorization involved deodorization by polyphenolic compounds without enzymatic activity. This probably occurred for microwaved apple, green tea, and lemon juice treatments. When pH is below 3.6, the enzyme alliinase is inactivated, which causes a reduction in volatile formation. This was demonstrated in pH-adjusted headspace measurements. However, the mechanism for volatile reduction on human breath (after volatile formation) is unclear, and may have occurred in soft drink and lemon juice breath treatments. Whey protein was not an effective garlic breath deodorant and had no enzymatic activity, polyphenolic compounds, or acidity. Headspace concentrations did not correlate well to breath treatments. © 2014 Institute of Food Technologists®

  19. The IsoDAR high intensity H2+ transport and injection tests

    NASA Astrophysics Data System (ADS)

    Alonso, J.; Axani, S.; Calabretta, L.; Campo, D.; Celona, L.; Conrad, J. M.; Day, A.; Castro, G.; Labrecque, F.; Winklehner, D.

    2015-10-01

    This technical report reviews the tests performed at the Best Cyclotron Systems, Inc. facility in regards to developing a cost effective ion source, beam line transport system, and acceleration system capable of high H2+ current output for the IsoDAR (Isotope Decay At Rest) experiment. We begin by outlining the requirements for the IsoDAR experiment then provide overviews of the Versatile Ion Source (VIS), Low Energy Beam Transport (LEBT) system, spiral inflector, and cyclotron. The experimental measurements are then discussed and the results are compared with a thorough set of simulation studies. Of particular importance we note that the VIS proved to be a reliable ion source capable of generating a large amount of H2+ current. The results suggest that with further upgrades, the VIS could potentially be a suitable candidate for IsoDAR. The conclusion outlines the key results from our tests and introduces the forthcoming work this technical report has motivated.

  20. Testing limits to airflow perturbation device (APD) measurements.

    PubMed

    Lopresti, Erika R; Johnson, Arthur T; Koh, Frank C; Scott, William H; Jamshidi, Shaya; Silverman, Nischom K

    2008-10-31

    The Airflow Perturbation Device (APD) is a lightweight, portable device that can be used to measure total respiratory resistance as well as inhalation and exhalation resistances. There is a need to determine limits to the accuracy of APD measurements for different conditions likely to occur: leaks around the mouthpiece, use of an oronasal mask, and the addition of resistance in the respiratory system. Also, there is a need for resistance measurements in patients who are ventilated. Ten subjects between the ages of 18 and 35 were tested for each station in the experiment. The first station involved testing the effects of leaks of known sizes on APD measurements. The second station tested the use of an oronasal mask used in conjunction with the APD during nose and mouth breathing. The third station tested the effects of two different resistances added in series with the APD mouthpiece. The fourth station tested the usage of a flexible ventilator tube in conjunction with the APD. All leaks reduced APD resistance measurement values. Leaks represented by two 3.2 mm diameter tubes reduced measured resistance by about 10% (4.2 cmH2O.sec/L for control and 3.9 cm H2O.sec/L for the leak). This was not statistically significant. Larger leaks given by 4.8 and 6.4 mm tubes reduced measurements significantly (3.4 and 3.0 cm cmH2O.sec/L, respectively). Mouth resistance measured with a cardboard mouthpiece gave an APD measurement of 4.2 cm H2O.sec/L and mouth resistance measured with an oronasal mask was 4.5 cm H2O.sec/L; the two were not significantly different. Nose resistance measured with the oronasal mask was 7.6 cm H2O.sec/L. Adding airflow resistances of 1.12 and 2.10 cm H2O.sec/L to the breathing circuit between the mouth and APD yielded respiratory resistance values higher than the control by 0.7 and 2.0 cm H2O.sec/L. Although breathing through a 52 cm length of flexible ventilator tubing reduced the APD measurement from 4.0 cm H2O.sec/L for the control to 3.6 cm H2O

  1. Optoacoustic Determination of Carbon Dioxide Concentration in Exhaled Breath in Various Human Diseases*

    NASA Astrophysics Data System (ADS)

    Ageev, V. G.; Nikiforova, O. Yu.

    2016-11-01

    We determined the carbon dioxide concentrations in exhaled breath from healthy donors and patients with various diseases from the absorption spectra of test samples, recorded on a laser optoacoustic gas analyzer based on a CO2 laser. We observed that the carbon dioxide concentrations in exhaled breath from healthy donors is higher than in patients with various diseases.

  2. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set forth in Tables 1, 2, 3, and 4 of this subpart, respectively, prescribe the duration and sequence of...

  3. Deep breathing exercises with positive expiratory pressure in patients with multiple sclerosis - a randomized controlled trial.

    PubMed

    Westerdahl, Elisabeth; Wittrin, Anna; Kånåhols, Margareta; Gunnarsson, Martin; Nilsagård, Ylva

    2016-11-01

    Breathing exercises with positive expiratory pressure are often recommended to patients with advanced neurological deficits, but the potential benefit in multiple sclerosis (MS) patients with mild and moderate symptoms has not yet been investigated in randomized controlled trials. To study the effects of 2 months of home-based breathing exercises for patients with mild to moderate MS on respiratory muscle strength, lung function, and subjective breathing and health status outcomes. Forty-eight patients with MS according to the revised McDonald criteria were enrolled in a randomized controlled trial. Patients performing breathing exercises (n = 23) were compared with a control group (n = 25) performing no breathing exercises. The breathing exercises were performed with a positive expiratory pressure device (10-15 cmH 2 O) and consisted of 30 slow deep breaths performed twice a day for 2 months. Respiratory muscle strength (maximal inspiratory and expiratory pressure at the mouth), spirometry, oxygenation, thoracic excursion, subjective perceptions of breathing and self-reported health status were evaluated before and after the intervention period. Following the intervention, there was a significant difference between the breathing group and the control group regarding the relative change in lung function, favoring the breathing group (vital capacity: P < 0.043; forced vital capacity: P < 0.025). There were no other significant differences between the groups. Breathing exercises may be beneficial in patients with mild to moderate stages of MS. However, the clinical significance needs to be clarified, and it remains to be seen whether a sustainable effect in delaying the development of respiratory dysfunction in MS can be obtained. © 2015 The Authors. The Clinical Respiratory Journal published by John Wiley & Sons Ltd.

  4. Partial liquid ventilation: effects of closed breathing systems, heat-and-moisture-exchangers and sodalime absorbers on perfluorocarbon evaporation.

    PubMed

    Wilms, C T; Schober, P; Kalb, R; Loer, S A

    2006-01-01

    During partial liquid ventilation perfluorocarbons are instilled into the airways from where they subsequently evaporate via the bronchial system. This process is influenced by multiple factors, such as the vapour pressure of the perfluorocarbons, the instilled volume, intrapulmonary perfluorocarbon distribution, postural positioning and ventilatory settings. In our study we compared the effects of open and closed breathing systems, a heat-and-moisture-exchanger and a sodalime absorber on perfluorocarbon evaporation during partial liquid ventilation. Isolated rat lungs were suspended from a force transducer. After intratracheal perfluorocarbon instillation (10 mL kg(-1)) the lungs were either ventilated with an open breathing system (n = 6), a closed breathing system (n = 6), an open breathing system with an integrated heat-and-moisture-exchanger (n = 6), an open breathing system with an integrated sodalime absorber (n = 6), or a closed breathing system with an integrated heat-and-moisture-exchanger and a sodalime absorber (n = 6). Evaporative perfluorocarbon elimination was determined gravimetrically. When compared to the elimination half-life in an open breathing system (1.2 +/- 0.07 h), elimination half-life was longer with a closed system (6.4 +/- 0.9 h, P 0.05) when compared to a closed system. Evaporative perfluorocarbon loss can be reduced effectively with closed breathing systems, followed by the use of sodalime absorbers and heat-and-moisture-exchangers.

  5. Sleep-disordered Breathing in Cardiac Rehabilitation: Prevalence, Predictors, and Influence on the Six-Minute Walk Test.

    PubMed

    Loo, Germaine; Chua, Ai-Ping; Tay, Hung-Yong; Poh, Ruth; Tai, Bee-Choo; Lee, Chi-Hang

    2016-06-01

    Identification of non-traditional risk factors is an important component of cardiac rehabilitation (CR). However, the prevalence and predictors of sleep-disordered breathing (SDB) and its influence on exercise performance in patients attending CR remain poorly described. Patients enrolled in a national CR centre were eligible for a comprehensive SDB screening program. Screening questionnaires for SDB, overnight sleep study, and the 6-minute walk test (6MWT) were conducted. We recruited 332 patients (mean age 62±10 years, 62.4% male) attending CR for primary (29.2%) or secondary (70.8%) prevention, of which 209 successfully completed the overnight sleep study. Sleep-disordered breathing group patients (n=68, 32.5%) were older and had a higher body mass index (BMI) and neck and waist circumferences than the non-SDB group patients. After adjusting for neck and waist circumference, age (OR=1.06; 95% CI 1.02-1.10; p=0.001) and BMI (OR=1.19; 95% CI 1.10-1.30; p<0.001) remained independent predictors of SDB. A high risk of SDB based on the Berlin Questionnaire (43.4% versus 35.5%, p=0.277) or STOP-BANG questionnaire (63.2% versus 53.2%, p=0.170) and excessive daytime sleepiness (Epworth Sleepiness Scale >10, 23.9% versus 17.7%, p=0.297) were similar between the groups. The 6MWT scores were significantly lower in the SDB than non-SDB group (mean difference -32 m; 95% CI -57-7; p=0.013). The relationship was no longer significant after adjusting for age, sex, and waist circumference. Sleep-disordered breathing is prevalent in CR patients and is independently predicted by ageing and obesity. The association between SDB and poorer exercise performance may be explained by age, sex, and waist circumference. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  6. Performance evaluation : balloon-type breath alcohol self tester for personal use

    DOT National Transportation Integrated Search

    1984-01-01

    The accuracy of the only breath alcohol balloon-type self test device being marketed for personal use (Luckey Laboratories DM-2) was assessed in the laboratory. Data regarding this self-test device's ability to accurately classify an individual as ha...

  7. Diagnostic accuracy of level 3 portable sleep tests versus level 1 polysomnography for sleep-disordered breathing: a systematic review and meta-analysis

    PubMed Central

    El Shayeb, Mohamed; Topfer, Leigh-Ann; Stafinski, Tania; Pawluk, Lawrence; Menon, Devidas

    2014-01-01

    Background: Greater awareness of sleep-disordered breathing and rising obesity rates have fueled demand for sleep studies. Sleep testing using level 3 portable devices may expedite diagnosis and reduce the costs associated with level 1 in-laboratory polysomnography. We sought to assess the diagnostic accuracy of level 3 testing compared with level 1 testing and to identify the appropriate patient population for each test. Methods: We conducted a systematic review and meta-analysis of comparative studies of level 3 versus level 1 sleep tests in adults with suspected sleep-disordered breathing. We searched 3 research databases and grey literature sources for studies that reported on diagnostic accuracy parameters or disease management after diagnosis. Two reviewers screened the search results, selected potentially relevant studies and extracted data. We used a bivariate mixed-effects binary regression model to estimate summary diagnostic accuracy parameters. Results: We included 59 studies involving a total of 5026 evaluable patients (mostly patients suspected of having obstructive sleep apnea). Of these, 19 studies were included in the meta-analysis. The estimated area under the receiver operating characteristics curve was high, ranging between 0.85 and 0.99 across different levels of disease severity. Summary sensitivity ranged between 0.79 and 0.97, and summary specificity ranged between 0.60 and 0.93 across different apnea–hypopnea cut-offs. We saw no significant difference in the clinical management parameters between patients who underwent either test to receive their diagnosis. Interpretation: Level 3 portable devices showed good diagnostic performance compared with level 1 sleep tests in adult patients with a high pretest probability of moderate to severe obstructive sleep apnea and no unstable comorbidities. For patients suspected of having other types of sleep-disordered breathing or sleep disorders not related to breathing, level 1 testing remains the

  8. Effect of oxygenation on breath-by-breath response of the genioglossus muscle during occlusion.

    PubMed

    Gauda, E B; Carroll, J L; McColley, S; Smith, P L

    1991-10-01

    We investigated the effect of different levels of O2 tension (hypoxia, normoxia, and hyperoxia) on the breath-by-breath onset and peak electromyographic (EMG) activity of the genioglossus (GG) muscle during a five-breath end-expiratory tracheal occlusion of 20- to 30-s duration. GG and diaphragmatic (DIA) EMG activity were measured with needle electrodes in eight anesthetized tracheotomized adult cats. In response to occlusion, the increase in the number of animals with GG EMG activity was different during hypoxia, normoxia, and hyperoxia (P = 0.003, Friedman). During hypoxia, eight of eight of the animals had GG EMG activity by the third occluded effort. In contrast, during normoxia, only four of eight and, during hyperoxia, only three of eight animals had GG EMG activity throughout the entire five-breath occlusion. Similarly, at release of the occlusion, more animals had persistent GG EMG activity on the postocclusion breaths during hypoxia than during normoxia or hyperoxia. Breath-by-breath augmentation of peak amplitude of the GG and DIA EMGs on each occluded effort was accentuated during hypoxia (P less than 0.01) and abolished during hyperoxia (P = 0.10). These results suggest that hypoxemia is a major determinant of the rapidity of onset, magnitude, and sustained activity of upper airway muscles during airway occlusion.

  9. Usefulness of rectally administering [1-(13)C]-butyrate for breath test in patients with active and quiescent ulcerative colitis.

    PubMed

    Kato, Kimitoshi; Ishii, Yukimoto; Mizuno, Shigeaki; Sugitani, Masahiko; Asai, Satoshi; Kohno, Tadashi; Takahashi, Katsuyuki; Komuro, Sachiko; Iwamoto, Maho; Miyamoto, Shunpachi; Takayama, Tadatoshi; Arakawa, Yasuyuki

    2007-02-01

    Impaired butyrate metabolism plays a part in ulcerative colitis (UC). To assess the usefulness of measuring butyrate metabolism as an indication of inflammatory activity, we investigated the rate of butyrate metabolism by breath test after administering [1-(13)C]-butyrate rectally to patients with UC. Thirty-eight UC patients (22 active, 16 quiescent) and 15 healthy controls were given [1-(13)C]-butyrate enemas. The (13)CO2 production rate was measured by breath test using an infrared spectrometric analyzer. The quantity of expired (13)CO2 was significantly lower in the active than in the quiescent UC and control groups. Cumulative (13)CO2 production at 240 min showed significant negative correlations with the clinical activity index (r=-0.65, p<0.0001), endoscopic activity index (r=-0.63, p=0.0001) and histology (r=-0.71, p<0.0001) in the active UC group. The (13)CO2 production rate was significantly increased in the quiescent stage as compared with the active stage in six UC patients, in whom clinical remission was achieved, in accordance with improvements in the clinical activity index, the endoscopic activity index, histology and fecal butyrate concentrations. Significant inverse correlations between the cumulative (13)CO2 production rate and these three parameters were seen in these six UC patients assessed in both the active and quiescent stages. Measurement of expired (13)CO2 after rectally administering [1-(13)C]-butyrate in active and quiescent UC appears to be a promising and reliable method for evaluating disease activity and metabolic changes associated with amelioration of inflammation.

  10. Optimising hydrogen peroxide measurement in exhaled breath condensate.

    PubMed

    Brooks, Wendy M; Lash, Heath; Kettle, Anthony J; Epton, Michael J

    2006-01-01

    Exhaled breath condensate (EBC) analysis has been proposed as a non-invasive method of assessing airway pathology. A number of substances, including hydrogen peroxide (H2O2), have been measured in EBC, without adequate published details of validation and optimisation. To explore factors that affect accurate quantitation of H2O2 in EBC. H2O2 was measured in EBC samples using fluorometry with 4-hydroxyphenylacetic acid. A number of factors that might alter quantitation were studied including pH and buffering conditions, reagent storage, and assay temperature. Standard curve slope was significantly altered by pH, leading to a potential difference in H2O2 quantification of up to 42%. These differences were resolved by increasing the buffering capacity of the reaction mix. H2O2 added to EBC remained stable for 1 h when stored on ice. The assay was unaffected by freezing assay reagents. The limit of detection for H2O2 ranged from 3.4 nM to 8.8 nM depending on the buffer used. The reagents required for this assay can be stored for several months allowing valuable consistency in longitudinal studies. The quantitation of H2O2 in EBC is pH-dependent but increasing assay buffering reduces this effect. Sensitive reproducible quantitation of H2O2 in EBC requires rigorous optimisation.

  11. Effect of Time-of-Flight Information on PET/MR Reconstruction Artifacts: Comparison of Free-breathing versus Breath-hold MR-based Attenuation Correction.

    PubMed

    Delso, Gaspar; Khalighi, Mohammed; Ter Voert, Edwin; Barbosa, Felipe; Sekine, Tetsuro; Hüllner, Martin; Veit-Haibach, Patrick

    2017-01-01

    Purpose To evaluate the magnitude and anatomic extent of the artifacts introduced on positron emission tomographic (PET)/magnetic resonance (MR) images by respiratory state mismatch in the attenuation map. Materials and Methods The method was tested on 14 patients referred for an oncologic examination who underwent PET/MR imaging. The acquisition included standard PET and MR series for each patient, and an additional attenuation correction series was acquired by using breath hold. PET data were reconstructed with and without time-of-flight (TOF) information, first by using the standard free-breathing attenuation map and then again by using the additional breath-hold map. Two-tailed paired t testing and linear regression with 0 intercept was performed on TOF versus non-TOF and free-breathing versus breath-hold data for all detected lesions. Results Fluorodeoxyglucose-avid lesions were found in eight of the 14 patients included in the study. The uptake differences (maximum standardized uptake values) between PET reconstructions with free-breathing versus breath-hold attenuation ranged, for non-TOF reconstructions, from -18% to 26%. The corresponding TOF reconstructions yielded differences from -15% to 18%. Conclusion TOF information was shown to reduce the artifacts caused at PET/MR by respiratory mismatch between emission and attenuation data. © RSNA, 2016 Online supplemental material is available for this article.

  12. Unilateral Ablation of Pre-Bötzinger Complex Disrupts Breathing during Sleep but Not Wakefulness

    PubMed Central

    McKay, Leanne C.; Feldman, Jack L.

    2008-01-01

    Rationale: In adult rats, bilateral ablation of pre-Bötzinger complex (preBötC) neurokinin 1–expressing (NK1R) neurons leads to a progressive and irreversible disruption in breathing pattern, initially during sleep, eventually resulting in an ataxic breathing pattern during wakefulness. Objectives: Here we determine whether ablation of fewer preBötC NK1R neurons leads to a persistent pattern of disordered breathing during sleep but not during wakefulness. Methods: Adult male Sprague-Dawley rats (n = 12) were instrumented to record diaphragmatic, abdominal, and neck EMG, and EEG. Fourteen days later, a second surgery was performed to stereotaxically microinject into the preBötC on one side the toxin saporin conjugated to substance P (SP-SAP), which selectively ablates NK1R neurons. Measurements and Main Results: Postinjection, rats were monitored within a plethysmograph until they were killed (Days 21–51). At Days 6–9 post–unilateral SP-SAP injection, respiratory pattern during sleep, particularly REM sleep, became increasingly disordered, characterized by an increase in frequency of central sleep apnea and hypopneas (36.8 ± 7.4 episodes/h of REM vs. 6 ± 2.0 episodes/h in preinjection controls; P < 0.05), whereas breathing during resting wakefulness remained stable. Unlike bilateral SP-SAP–injected rats, an ataxic breathing pattern did not develop during wakefulness. Rats that were monitored up to 51 days post–SP-SAP injection continued to have sleep-disordered breathing; breathing during wakefulness remained relatively stable. Histologic analysis of the ventrolateral medulla confirmed that NK1R neurons within the preBötC on the injected but not on the contralateral side of the medulla were ablated. Conclusions: Gradual loss of preBötC NK1R neurons may be an underlying factor of sleep-disordered breathing, in particular of central sleep apnea. PMID:18420958

  13. Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications

    PubMed Central

    Lourenço, Célia; Turner, Claire

    2014-01-01

    Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. “Breath fingerprinting”, indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles. PMID:24957037

  14. Insulin sensitivity index (ISI0, 120) potentially linked to carbon isotopes of breath CO2 for pre-diabetes and type 2 diabetes

    PubMed Central

    Ghosh, Chiranjit; Mukhopadhyay, Prabuddha; Ghosh, Shibendu; Pradhan, Manik

    2015-01-01

    New strategies for an accurate and early detection of insulin resistance are important to delay or prevent the acute onset of type 2 diabetes (T2D). Currently, insulin sensitivity index (ISI0,120) is considered to be a viable invasive method of whole-body insulin resistance for use in clinical settings in comparison with other invasive sensitivity indexes like homeostasis model assessment (HOMA), and quantitative insulin sensitivity check index (QUICKI). To investigate how these sensitivity indexes link the 13C/12C-carbon isotopes of exhaled breath CO2 to pre-diabetes (PD) and type 2 diabetes in response to glucose ingestion, we studied excretion dynamics of 13C/12C-isotopic fractionations of breath CO2. Here, we show that 13C/12C-isotope ratios of breath CO2 were well correlated with blood glucose, insulin, glycosylated-hemoglobin as well as with HOMA-IR and 1/QUICKI. Conversely, the strongest correlation was observed between 1/ISI0,120 and breath CO2 isotopes. Consequently, we determined several optimal diagnostic cut-off points of 1/ISI0,120 and 13CO2/12CO2-isotope ratios to distinctively track the evolution of PD prior to the onset of T2D. Our findings suggest that isotopic breath CO2 is a novel method for accurate estimation of ISI0,120 and thus may open new perspectives into the isotope-specific non-invasive evaluation of insulin resistance for large-scale real-time diabetes screening purposes. PMID:26148706

  15. Use of warrants for breath test refusal : case studies

    DOT National Transportation Integrated Search

    2007-10-01

    This study investigated the use of warrants to obtain blood samples from drivers arrested for alcohol-impaired driving and who refuse to provide breath samples when requested to do so by law enforcement officers. Case studies were conducted in four S...

  16. Breathing regulation and blood gas homeostasis after near complete lesions of the retrotrapezoid nucleus in adult rats.

    PubMed

    Souza, George M P R; Kanbar, Roy; Stornetta, Daniel S; Abbott, Stephen B G; Stornetta, Ruth L; Guyenet, Patrice G

    2018-04-18

    The retrotrapezoid nucleus (RTN) is one of several CNS nuclei that contribute, in various capacities (e.g. CO 2 detection, neuronal modulation) to the central respiratory chemoreflex (CRC). Here we test how important the RTN is to PCO 2 homeostasis and breathing during sleep or wake. RTN Nmb positive neurons were killed with targeted microinjections of substance-P-saporin conjugate in adult rats. Under normoxia, rats with large RTN lesions (92 ± 4 % cell loss) had normal blood pressure (BP) and arterial pH but were hypoxic (-8 mmHg PaO 2 ) and hypercapnic (+10 mmHg PaCO 2 ). In resting conditions, minute-volume (V E ) was normal but breathing frequency (f R ) was elevated and tidal volume (V T ) reduced. Resting O 2 consumption and CO 2 production were normal. The hypercapnic ventilatory reflex in 65% FiO 2 had an inverse exponential relationship with the number of surviving RTN neurons and was decreased by up to 92%. The hypoxic ventilatory reflex (HVR; FiO 2 21-10%) persisted after RTN lesions, hypoxia-induced sighing was normal and hypoxia-induced hypotension reduced. In rats with RTN lesions, breathing was lowest during slow-wave sleep (SWS), especially under hyperoxia, but apneas and sleep-disordered breathing were not observed. In conclusion, near complete RTN destruction in rats virtually eliminates the CRC but HVR persists and sighing and the state-dependence of breathing are unchanged. Under normoxia, RTN lesions cause no change in V E but alveolar ventilation is reduced by at least 21%, probably because of increased physiological dead volume. RTN lesions do not cause sleep apnea during SWS, even under hyperoxia. Background: the retrotrapezoid nucleus (RTN) drives breathing proportionally to brain PCO 2 but its role during various states of vigilance needed clarification. New result: Under normoxia, RTN lesions increase the arterial PCO 2 set-point, lower the PO 2 set-point and reduce alveolar ventilation relative to CO 2 production. Tidal volume is

  17. Application of ion chemistry and the SIFT technique to the quantitative analysis of trace gases in air and on breath

    NASA Astrophysics Data System (ADS)

    Smith, David; Španěl, Patrik

    Our major objective in this paper is to describe a new method we have developed for the analysis of trace gases at partial pressures down to the ppb level in atmospheric air, with special emphasis on the detection and quantification of trace gases on human breath. It involves the use of our selected ion flow tube (Sift) technique which we previously developed and used extensively for the study of gas phase ionic reactions occurring in ionized media such as the terrestrial atmosphere and interstellar gas clouds. Before discussing this analytical technique we describe the results of our very recent Sift and flowing afterglow (FA) studies of the reactions of the H3O+ and OH- ions, of their hydrates H3O+(H2O)1,2,3 and OH- (H2O)1,2, and of NO+ and O2+, with several hydrocarbons and oxygen-bearing organic molecules, studies that are very relevant to our trace gas analytical studies. Then follows a detailed discussion of the application of our Sift technique to trace gas analysis, after which we present some results obtained for the analyses of laboratory air, the breath of a healthy non-smoking person, the breath of a person who regularly smokes cigarettes, the complex vapours emitted by banana and onion, and the molecules present in a butane/air flame. We show how the quantitative analysis of breath can be achieved from only a single exhalation and in real time (the time response of the instrument is only about 20 ms). We also show how the time variation of breath gases over long time periods can be followed, using the decay of ethanol on the breath after the ingestion of distilled liquor as an example, yet simultaneously following several other trace gases including acetone and isoprene which are very easily detected on the breath of all individuals because of their relatively high partial pressures (typically 100 to 1000 ppb). The breath of a smoker is richer in complex molecules, some nitrogen containing organics apparently being very evident at the 5 to 50 ppb level

  18. Design, fabrication and testing of an air-breathing micro direct methanol fuel cell with compound anode flow field

    NASA Astrophysics Data System (ADS)

    Wang, Luwen; Zhang, Yufeng; Zhao, Youran; An, Zijiang; Zhou, Zhiping; Liu, Xiaowei

    2011-10-01

    An air-breathing micro direct methanol fuel cell (μDMFC) with a compound anode flow field structure (composed of the parallel flow field and the perforated flow field) is designed, fabricated and tested. To better analyze the effect of the compound anode flow field on the mass transfer of methanol, the compound flow field with different open ratios (ratio of exposure area to total area) and thicknesses of current collectors is modeled and simulated. Micro process technologies are employed to fabricate the end plates and current collectors. The performances of the μDMFC with a compound anode flow field are measured under various operating parameters. Both the modeled and the experimental results show that, comparing the conventional parallel flow field, the compound one can enhance the mass transfer resistance of methanol from the flow field to the anode diffusion layer. The results also indicate that the μDMFC with an anode open ratio of 40% and a thickness of 300 µm has the optimal performance under the 7 M methanol which is three to four times higher than conventional flow fields. Finally, a 2 h stability test of the μDMFC is performed with a methanol concentration of 7 M and a flow velocity of 0.1 ml min-1. The results indicate that the μDMFC can work steadily with high methanol concentration.

  19. Breathing is affected by dopamine D2-like receptors in the basolateral amygdala.

    PubMed

    Sugita, Toshihisa; Kanamaru, Mitsuko; Iizuka, Makito; Sato, Kanako; Tsukada, Setsuro; Kawamura, Mitsuru; Homma, Ikuo; Izumizaki, Masahiko

    2015-04-01

    The precise mechanisms underlying how emotions change breathing patterns remain unclear, but dopamine is a candidate neurotransmitter in the process of emotion-associated breathing. We investigated whether basal dopamine release occurs in the basolateral amygdala (BLA), where sensory-related inputs are received and lead to fear or anxiety responses, and whether D1- and D2-like receptor antagonists affect breathing patterns and dopamine release in the BLA. Adult male mice (C57BL/6N) were perfused with artificial cerebrospinal fluid, a D1-like receptor antagonist (SCH 23390), or a D2-like receptor antagonist ((S)-(-)-sulpiride) through a microdialysis probe in the BLA. Respiratory variables were measured using a double-chamber plethysmograph. Dopamine release was measured by an HPLC. Perfusion of (S)-(-)-sulpiride in the BLA, not SCH 23390, specifically decreased respiratory rate without changes in local release of dopamine. These results suggest that basal dopamine release in the BLA, at least partially, increases respiratory rates only through post-synaptic D2-like receptors, not autoreceptors, which might be associated with emotional responses. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. hCG Test (Pregnancy Test)

    MedlinePlus

    ... Time and International Normalized Ratio (PT/INR) PSEN1 Quantitative Immunoglobulins Red Blood Cell (RBC) Antibody Identification Red ... Us Also Known As Pregnancy Test Qualitative hCG Quantitative hCG Beta hCG Total hCG Total beta hCG ...

  1. Effect of upper costal and costo-diaphragmatic breathing types on electromyographic activity of respiratory muscles.

    PubMed

    Celhay, Isabel; Cordova, Rosa; Miralles, Rodolfo; Meza, Francisco; Erices, Pia; Barrientos, Camilo; Valenzuela, Saúl

    2015-04-01

    To compare electromyographic (EMG) activity in young-adult subjects with different breathing types. This study included 50 healthy male subjects with complete natural dentition, and no history of orofacial pain or craniomandibular-cervical-spinal disorders. Subjects were classified into two groups: upper costal breathing type, and costo-diaphragmatic breathing. Bipolar surface electrodes were located on sternocleidomastoid, diaphragm, external intercostal, and latissimus dorsi muscles. Electromyographic activity was recorded during the following tasks: (1) normal quiet breathing; (2) speaking the word 'Mississippi'; (3) swallowing saliva; and (4) forced deep breathing. Sternocleidomastoid and latissimus dorsi EMG activity was not significantly different between breathing types, whereas diaphragm and external intercostal EMG activity was significantly higher in the upper costal than costo-diaphragmatic breathing type in all tasks (P<0·05; Wilcoxon signed rank-sum test). Diaphragm and external intercostal EMG activity suggests that there could be differences in motor unit recruitment strategies depending on the breathing type.

  2. Reliable quantification of BOLD fMRI cerebrovascular reactivity despite poor breath-hold performance.

    PubMed

    Bright, Molly G; Murphy, Kevin

    2013-12-01

    Cerebrovascular reactivity (CVR) can be mapped using BOLD fMRI to provide a clinical insight into vascular health that can be used to diagnose cerebrovascular disease. Breath-holds are a readily accessible method for producing the required arterial CO2 increases but their implementation into clinical studies is limited by concerns that patients will demonstrate highly variable performance of breath-hold challenges. This study assesses the repeatability of CVR measurements despite poor task performance, to determine if and how robust results could be achieved with breath-holds in patients. Twelve healthy volunteers were scanned at 3 T. Six functional scans were acquired, each consisting of 6 breath-hold challenges (10, 15, or 20 s duration) interleaved with periods of paced breathing. These scans simulated the varying breath-hold consistency and ability levels that may occur in patient data. Uniform ramps, time-scaled ramps, and end-tidal CO2 data were used as regressors in a general linear model in order to measure CVR at the grey matter, regional, and voxelwise level. The intraclass correlation coefficient (ICC) quantified the repeatability of the CVR measurement for each breath-hold regressor type and scale of interest across the variable task performances. The ramp regressors did not fully account for variability in breath-hold performance and did not achieve acceptable repeatability (ICC<0.4) in several regions analysed. In contrast, the end-tidal CO2 regressors resulted in "excellent" repeatability (ICC=0.82) in the average grey matter data, and resulted in acceptable repeatability in all smaller regions tested (ICC>0.4). Further analysis of intra-subject CVR variability across the brain (ICCspatial and voxelwise correlation) supported the use of end-tidal CO2 data to extract robust whole-brain CVR maps, despite variability in breath-hold performance. We conclude that the incorporation of end-tidal CO2 monitoring into scanning enables robust, repeatable

  3. A study of the methodological and clinical validity of the combined lactulose hydrogen breath test with scintigraphic oro-cecal transit test for diagnosing small intestinal bacterial overgrowth in IBS patients.

    PubMed

    Zhao, J; Zheng, X; Chu, H; Zhao, J; Cong, Y; Fried, M; Fox, M; Dai, N

    2014-06-01

    Small intestinal bacterial overgrowth (SIBO) may be a cause of irritable bowel syndrome (IBS); however, current investigations have important limitations. We aimed to identify clinically relevant diagnostic criteria for SIBO based on lactulose hydrogen breath test (LHBT) alone and combined with scintigraphic measurement of oro-cecal transit (SOCT). Results of LHBT/SOCT investigation from 89 IBS patients and 13 healthy volunteers were included in a systematic analysis of six published criteria for SIBO diagnosis. Clinical relevance of competing criteria was determined by assessing (i) prevalence of SIBO in IBS patients and healthy volunteers (ii) if SIBO diagnosis predicted improvement in IBS symptoms in a prospective, pilot therapeutic trial of a non-absorbable antibiotic (rifaximin 600 mg b.d.) in IBS patients. Reproducibility of SIBO diagnosis by combined LHBT/SOCT was near perfect. A ≥5 ppm H2 increase prior to appearance of cecal contrast was detected in more IBS patients than healthy volunteers (35/89 vs 1/13; p = 0.026), but not for other diagnostic criteria. IBS patients with SIBO, compared to those without SIBO, reported significantly greater improvement in abdominal symptoms following rifaximin therapy (p < 0.002 overall IBS symptom severity). This improvement was most marked in D-IBS patients in whom all symptoms improved, including stool frequency and consistency (all p < 0.004). Combined LHBT/SOCT testing using a H2 5 ppm cutoff may identify a subgroup of IBS patients with SIBO. Pilot data examining the clinical response to rifaximin suggest that this subset of IBS patients may benefit more than those with a normal test. © 2014 John Wiley & Sons Ltd.

  4. Cardiorespiratory responses to hypoxia in the African catfish, Clarias gariepinus (Burchell 1822), an air-breathing fish.

    PubMed

    Belão, T C; Leite, C A C; Florindo, L H; Kalinin, A L; Rantin, F T

    2011-10-01

    The African catfish, Clarias gariepinus, possesses a pair of suprabranchial chambers located in the dorsal-posterior part of the branchial cavity having extensions from the upper parts of the second and fourth gill arches, forming the arborescent organs. This structure is an air-breathing organ (ABO) and allows aerial breathing (AB). We evaluated its cardiorespiratory responses to aquatic hypoxia. To determine the mode of air-breathing (obligate or accessory), fish had the respiratory frequency (f (R)) monitored and were subjected to normoxic water (PwO(2) = 140 mmHg) without becoming hyperactive for 30 h. During this period, all fish survived without displaying evidences of hyperactivity and maintained unchanged f (R), confirming that this species is a facultative air-breather. Its aquatic O(2) uptake ([Formula: see text]) was maintained constant down to a critical PO(2) (PcO(2)) of 60 mmHg, below which [Formula: see text] declined linearly with further reductions of inspired O(2) tension (PiO(2)). Just above the PcO(2) the ventilatory tidal volume (V (T)) increased significantly along with gill ventilation ([Formula: see text]), while f (R) changed little. Consequently, the water convection requirement [Formula: see text] increased steeply. This threshold applied to a cardiac response that included reflex bradycardia. AB was initiated at PiO(2) = 140 mmHg (normoxia) and air-breathing episodes increased linearly with more severe hypoxia, being significantly higher at PiO(2) tensions below the PcO(2). Air-breathing episodes were accompanied by bradycardia pre air-breath, to tachycardia post air-breath.

  5. Protein kinase G–regulated production of H2S governs oxygen sensing

    PubMed Central

    Yuan, Guoxiang; Vasavda, Chirag; Peng, Ying-Jie; Makarenko, Vladislav V.; Raghuraman, Gayatri; Nanduri, Jayasri; Gadalla, Moataz M.; Semenza, Gregg L.; Kumar, Ganesh K.; Snyder, Solomon H.; Prabhakar, Nanduri R.

    2015-01-01

    Reflexes initiated by the carotid body, the principal O2-sensing organ, are critical for maintaining cardio-respiratory homeostasis during hypoxia. O2 sensing by the carotid body requires carbon monoxide (CO) generation by heme oxygenase-2 (HO-2) and hydrogen sulfide (H2S) synthesis by cystathionine-γ-lyase (CSE). We report that O2 stimulated the generation of CO, but not that of H2S, and required two cysteine residues in the heme regulatory motif (Cys265 and Cys282) of HO-2. CO stimulated protein kinase G (PKG)–dependent phosphorylation of Ser377 of CSE, inhibiting the production of H2S. Hypoxia decreased the inhibition of CSE by reducing CO generation resulting in increased H2S, which stimulated carotid body neural activity. In carotid bodies from mice lacking HO-2, compensatory increased abundance of nNOS (neuronal nitric oxide synthase) mediated O2 sensing through PKG-dependent regulation of H2S by nitric oxide. These results provide a mechanism for how three gases work in concert in the carotid body to regulate breathing. PMID:25900831

  6. A chlorate candle/lithium hydroxide personal breathing apparatus

    NASA Technical Reports Server (NTRS)

    Martin, F. E.

    1972-01-01

    A portable coal mine rescue and survival equipment is reported that consists of a chlorate candle with a lithium hydroxide carbon-dioxide absorbent for oxygen generation, a breathing bag and tubing to conduct breathing to and from the man. A plastic hood incorporating a mouth piece for communication provides also eye protection and prevents inhalation through the nose. Manned testing of a prototype system demonstrated the feasibility of this closed circuit no-maintenance breathing apparatus that provides for good voice communication.

  7. Respiratory mechanics and breathing pattern in the neonatal foal.

    PubMed

    Koterba, A M; Kosch, P C

    1987-01-01

    Breathing pattern, respiratory muscle activation pattern, lung volumes and volume-pressure characteristics of the respiratory system of normal, term, neonatal foals on Days 2 and 7 of age were determined to test the hypothesis that the foal actively maintains end-expiratory lung volume (EEV) greater than the relaxation volume of the respiratory system (Vrx) because of a highly compliant chest wall. Breathing pattern was measured in the awake, unsedated foal during quiet breathing in lateral and standing positions. The typical neonatal foal breathing pattern was characterized by a monophasic inspiratory and expiratory flow pattern. Both inspiration and expiration were active, with onset of Edi activity preceding onset of inspiratory flow, and phasic abdominal muscle activity detectable throughout most of expiration. No evidence was found to support the hypothesis that the normal, term neonatal foal actively maintains EEV greater than Vrx. In the neonatal foal, normalized lung volume and lung compliance values were similar to those reported for neonates of other species, while normalized chest wall compliance was considerably lower. We conclude that the chest wall of the term neonatal foal is sufficiently rigid to prevent a low Vrx. This characteristic probably prevents the foal from having to use a breathing strategy which maintains an EEV greater than Vrx.

  8. Hepatobiliary MRI: Signal intensity based assessment of liver function correlated to 13C-Methacetin breath test.

    PubMed

    Haimerl, Michael; Probst, Ute; Poelsterl, Stefanie; Beyer, Lukas; Fellner, Claudia; Selgrad, Michael; Hornung, Matthias; Stroszczynski, Christian; Wiggermann, Philipp

    2018-06-13

    Gadoxetic acid (Gd-EOB-DTPA) is a paramagnetic MRI contrast agent with raising popularity and has been used for evaluation of imaging-based liver function in recent years. In order to verify whether liver function as determined by real-time breath analysis using the intravenous administration of 13 C-methacetin can be estimated quantitatively from Gd-EOB-DTPA-enhanced MRI using signal intensity (SI) values. 110 patients underwent Gd-EOB-DTPA-enhanced 3-T MRI and, for the evaluation of liver function, a 13 C-methacetin breath test ( 13 C-MBT). SI values from before (SI pre ) and 20 min after (SI post ) contrast media injection were acquired by T1-weighted volume-interpolated breath-hold examination (VIBE) sequences with fat suppression. The relative enhancement (RE) between the plain and contrast-enhanced SI values was calculated and evaluated in a correlation analysis of 13 C-MBT values to SI post and RE to obtain a SI-based estimation of 13 C-MBT values. The simple regression model showed a log-linear correlation of 13 C-MBT values with SI post and RE (p < 0.001). Stratified by 3 different categories of 13 C-MBT readouts, there was a constant significant decrease in both SI post (p ≤ 0.002) and RE (p ≤ 0.033) with increasing liver disease progression as assessed by the 13 C-MBT. Liver function as determined using real-time 13 C-methacetin breath analysis can be estimated quantitatively from Gd-EOB-DTPA-enhanced MRI using SI-based indices.

  9. The cholesteryl octanoate breath test: a new procedure for detection of pancreatic insufficiency in the rat.

    PubMed

    Mundlos, S; Rhodes, J B; Hofmann, A F

    1987-09-01

    A breath test for the detection of pancreatic insufficiency was developed and tested in rats. The test features the hydrophobic molecule cholesteryl-1-14C-octanoate, which liberates 14C-octanoic acid when hydrolyzed by carboxyl ester lipase (cholesterol esterase). The 14C-octanoate is absorbed passively and rapidly metabolized to 14CO2, which is excreted in expired air. The compound was administered as an emulsion of cholesteryl octanoate, triglyceride, and lecithin to rats with mild pancreatic insufficiency induced by injecting the pancreatic duct with zein. The animals had exocrine pancreatic hypofunction based on the enzyme content of pancreas at autopsy. Amylase was reduced by 97.1 +/- 1.4%, whereas chymotrypsin was reduced by 73 +/- 14%. The p-aminobenzoic acid test was abnormal at 1 wk (21.68 +/- 8.4%), but become normal at 3 months (72.08 +/- 5.8%) after zein injection. Despite this, the animals gained weight and absorbed fat normally. The 14CO2 excretion rate in the 110-min interval after feeding was significantly reduced to 60% of sham-operated animals. Peak 14CO2 collections 20 min after feeding were reduced by 75 +/- 11%. 14CO2 output was completely normalized by administration of pancreatin prior to the test meal. The results suggest that a sensitive, noninvasive method for detecting deficiency of pancreatic carboxyl ester lipase (cholesterol esterase) secretion in the rat has been developed.

  10. Cubic PdNP-based air-breathing cathodes integrated in glucose hybrid biofuel cells

    NASA Astrophysics Data System (ADS)

    Faggion Junior, D.; Haddad, R.; Giroud, F.; Holzinger, M.; Maduro de Campos, C. E.; Acuña, J. J. S.; Domingos, J. B.; Cosnier, S.

    2016-05-01

    Cubic Pd nanoparticles (PdNPs) were synthesized using ascorbic acid as a reducing agent and were evaluated for the catalytic oxygen reduction reaction. PdNPs were confined with multiwalled carbon nanotube (MWCNT) dispersions to form black suspensions and these inks were dropcast onto glassy carbon electrodes. Different nanoparticle sizes were synthesized and investigated upon oxygen reduction capacities (onset potential and electrocatalytic current densities) under O2 saturated conditions at varying pH values. Strong evidence of O2 diffusion limitation was demonstrated. In order to overcome oxygen concentration and diffusion limitations in solution, we used a gas diffusion layer to create a PdNP-based air-breathing cathode, which delivered -1.5 mA cm-2 at 0.0 V with an onset potential of 0.4 V. This air-breathing cathode was combined with a specially designed phenanthrolinequinone/glucose dehydrogenase-based anode to form a complete glucose/O2 hybrid bio-fuel cell providing an open circuit voltage of 0.554 V and delivering a maximal power output of 184 +/- 21 μW cm-2 at 0.19 V and pH 7.0.Cubic Pd nanoparticles (PdNPs) were synthesized using ascorbic acid as a reducing agent and were evaluated for the catalytic oxygen reduction reaction. PdNPs were confined with multiwalled carbon nanotube (MWCNT) dispersions to form black suspensions and these inks were dropcast onto glassy carbon electrodes. Different nanoparticle sizes were synthesized and investigated upon oxygen reduction capacities (onset potential and electrocatalytic current densities) under O2 saturated conditions at varying pH values. Strong evidence of O2 diffusion limitation was demonstrated. In order to overcome oxygen concentration and diffusion limitations in solution, we used a gas diffusion layer to create a PdNP-based air-breathing cathode, which delivered -1.5 mA cm-2 at 0.0 V with an onset potential of 0.4 V. This air-breathing cathode was combined with a specially designed phenanthrolinequinone

  11. Effects of sodium lauryl sulphate (SLS), present in dentifrice, on volatile sulphur compound (VSC) formation in morning bad breath.

    PubMed

    Peruzzo, Daiane Cristina; Salvador, Sérgio Luis; Sallum, Antonio Wilson; da Nogueira-Filho, Getúlio Rocha

    2008-10-01

    The purpose of the present investigation was to evaluate the effects of sodium lauryl sulphate (SLS), present in a commercial dentifrice, on the formation of volatile sulphur compounds (VSC) and tongue coating in a panel of periodontally healthy subjects. A two-step blinded, crossover, randomized study was carried out in 25 dental students with healthy periodontium; these were divided into two experimental groups: SLS (dentifrice with SLS) and WSLS (dentifrice without SLS). The volunteers received the designated dentifrice and a new toothbrush for a 3x/day brushing regimen for 2 periods of 30 days. A seven-day washout interval was used between the periods. The assessed parameters were: plaque index (PI), gingival index (GI), organoleptic breath (ORG), VSC levels by portable sulphide monitor before (H1) and after (H2) cleaning of the tongue, tongue coating wet weight (TC) and benzoyl-DL-arginine-naphthylamide (BANA) test from tongue coating samples. The intra-group analysis showed a decrease in the median of organoleptic scores from 3 to 2 after 30 days for the SLS group (p < 0.05). The inter-group analysis showed lower values in ORG and H1 for the SLS group (p < 0.05). There was no difference between the amount of TC in SLS and WSLS groups. In the BANA test, the presence of SLS did not affect the BANA number of +/- results (p > 0.05). These findings suggest that sodium lauryl sulphate (SLS), present in dentifrice, appears to prevent VSC formation in morning bad breath regardless of the amount of tongue coating in periodontally healthy subjects.

  12. QED Effects in Molecules: Test on Rotational Quantum States of H2

    NASA Astrophysics Data System (ADS)

    Salumbides, E. J.; Dickenson, G. D.; Ivanov, T. I.; Ubachs, W.

    2011-07-01

    Quantum electrodynamic effects have been systematically tested in the progression of rotational quantum states in the XΣg+1, v=0 vibronic ground state of molecular hydrogen. High-precision Doppler-free spectroscopy of the EFΣg+1-XΣg+1 (0,0) band was performed with 0.005cm-1 accuracy on rotationally hot H2 (with rotational quantum states J up to 16). QED and relativistic contributions to rotational level energies as high as 0.13cm-1 are extracted, and are in perfect agreement with recent calculations of QED and high-order relativistic effects for the H2 ground state.

  13. Noninvasive detection of lung cancer using exhaled breath

    PubMed Central

    Fu, Xiao-An; Li, Mingxiao; Knipp, Ralph J; Nantz, Michael H; Bousamra, Michael

    2014-01-01

    Early detection of lung cancer is a key factor for increasing the survival rates of lung cancer patients. The analysis of exhaled breath is promising as a noninvasive diagnostic tool for diagnosis of lung cancer. We demonstrate the quantitative analysis of carbonyl volatile organic compounds (VOCs) and identification of lung cancer VOC markers in exhaled breath using unique silicon microreactor technology. The microreactor consists of thousands of micropillars coated with an ammonium aminooxy salt for capture of carbonyl VOCs in exhaled breath by means of oximation reactions. Captured aminooxy-VOC adducts are analyzed by nanoelectrospray Fourier transform-ion cyclotron resonance (FT-ICR) mass spectrometry (MS). The concentrations of 2-butanone, 2-hydroxyacetaldehyde, 3-hydroxy-2-butanone, and 4-hydroxyhexenal (4-HHE) in the exhaled breath of lung cancer patients (n = 97) were significantly higher than in the exhaled breath of healthy smoker and nonsmoker controls (n = 88) and patients with benign pulmonary nodules (n = 32). The concentration of 2-butanone in exhaled breath of patients (n = 51) with stages II though IV non–small cell lung cancer (NSCLC) was significantly higher than in exhaled breath of patients with stage I (n = 34). The carbonyl VOC profile in exhaled breath determined using this new silicon microreactor technology provides for the noninvasive detection of lung cancer. PMID:24402867

  14. Epilepsy and the ketogenic diet: assessment of ketosis in children using breath acetone.

    PubMed

    Musa-Veloso, Kathy; Rarama, Exequiel; Comeau, Felix; Curtis, Rosalind; Cunnane, Stephen

    2002-09-01

    High-fat ketogenic diets increase ketones (acetoacetate, beta-hydroxybutyrate, and acetone) and are used to treat refractory seizures. Although ketosis is an integral aspect of these therapeutic regimens, the direct importance of ketosis to seizure control needs further investigation. An examination of this relationship requires a reliable, minimally invasive measure of ketosis that can be performed frequently. In the present study, we examined the use of breath acetone as a measure of ketosis in children with refractory seizures on a classic ketogenic diet. Results were compared with breath acetone levels in epilepsy and healthy controls. Children on the ketogenic diet had significantly higher fasting breath acetone compared with epilepsy or healthy controls (2530 +/- 600 nmol/L versus 19 +/- 9 nmol/L and 21 +/- 4 nmol/L, respectively; p < 0.05). One hour after consumption of a ketogenic breakfast meal, breath acetone increased significantly in epilepsy and healthy controls (p < 0.05), but not in children on a ketogenic diet. Children who were on the ketogenic diet for longer periods of time had a significantly lower fasting breath acetone (R(2) = 0.55, p = 0.014). In one child on the ketogenic diet, breath acetone was determined hourly over a 9-h period, both by gas chromatography and by a prototype hand-held breath acetone analyzer. Preliminary results using this hand-held breath acetone analyzer are encouraging. Breath acetone may be a useful tool in examining the relationship between ketosis and seizure control and enhancing our understanding of the mechanism of the ketogenic diet.

  15. Early detection of cystic fibrosis lung disease: multiple‐breath washout versus raised volume tests

    PubMed Central

    Lum, Sooky; Gustafsson, Per; Ljungberg, Henrik; Hülskamp, Georg; Bush, Andrew; Carr, Siobhán B; Castle, Rosemary; Hoo, Ah‐fong; Price, John; Ranganathan, Sarath; Stroobant, John; Wade, Angie; Wallis, Colin; Wyatt, Hilary; Stocks, Janet

    2007-01-01

    Background Lung clearance index (LCI), a measure of ventilation inhomogeneity derived from the multiple‐breath inert gas washout (MBW) technique, has been shown to detect abnormal lung function more readily than spirometry in preschool children with cystic fibrosis, but whether this holds true during infancy is unknown. Objectives To compare the extent to which parameters derived from the MBW and the raised lung volume rapid thoraco–abdominal compression (RVRTC) techniques identify diminished airway function in infants with cystic fibrosis when compared with healthy controls. Methods Measurements were performed during quiet sleep, with the tidal breathing MBW technique being performed before the forced expiratory manoeuvres. Results Measurements were obtained in 39 infants with cystic fibrosis (mean (SD) age 41.4 (22.0) weeks) and 21 controls (37.0 (15.1) weeks). Infants with cystic fibrosis had a significantly higher respiratory rate (38 (10) vs 32 (5) bpm) and LCI (8.4 (1.5) vs 7.2 (0.3)), and significantly lower values for all forced expiratory flow‐volume parameters compared with controls. Girls with cystic fibrosis had significantly lower forced expiratory volume (FEV0.5 and FEF25–75 ) than boys (mean (95% CI girls–boys): –1.2 (–2.1 to −0.3) for FEV0.5 Z score; FEF25–75: –1.2 (–2.2 to −0.15)). When using both the MBW and RVRTC techniques, abnormalities were detected in 72% of the infants with cystic fibrosis, with abnormalities detected in 41% using both techniques and a further 15% by each of the two tests performed. Conclusions These findings support the view that inflammatory and/or structural changes in the airways of children with cystic fibrosis start early in life, and have important implications regarding early detection and interventions. Monitoring of early lung disease and functional status in infants and young children with cystic fibrosis may be enhanced by using both MBW and the RVRTC. PMID:17121870

  16. 2-D Air-Breathing Lightcraft Engine Experiments in Hypersonic Conditions

    NASA Astrophysics Data System (ADS)

    Salvador, Israel I.; Myrabo, Leik N.; Minucci, Marco A. S.; de Oliveira, Antonio C.; Toro, Paulo G. P.; Chanes, José B.; Rego, Israel S.

    2011-11-01

    Experiments were performed with a 2-D, repetitively-pulsed (RP) laser Lightcraft model in hypersonic flow conditions. The main objective was the feasibility analysis for impulse generation with repetitively-pulsed air-breathing laser Lightcraft engines at hypersonic speeds. The future application of interest for this basic research endeavor is the laser launch of pico-, nano-, and micro-satellites (i.e., 0.1-100 kg payloads) into Low-Earth-Orbit, at low-cost and on-demand. The laser propulsion experiments employed a Hypersonic Shock Tunnel integrated with twin gigawatt pulsed Lumonics 620-TEA CO2 lasers (˜ 1 μs pulses), to produce the required test conditions. This hypersonic campaign was carried out at nominal Mach numbers ranging from 6 to 10. Time-dependent surface pressure distributions were recorded together with Schlieren movies of the flow field structure resulting from laser energy deposition. Results indicated laser-induced pressure increases of 0.7-0.9 bar with laser pulse energies of ˜ 170 J, on off-shroud induced breakdown condition, and Mach number of 7.

  17. Development tests of LOX/LH2 tank for H-I launch vehicle

    NASA Astrophysics Data System (ADS)

    Takamatsu, H.; Imagawa, K.; Ichimaru, Y.

    1984-10-01

    The design and preliminary test performance of an integrated LOX/LH2 tank for the second-stage propulsion system of the H-I launch be vehicle being developed by NASDA are presented and illustrated with drawings, diagrams, photographs, graphs, and tables. The tank has length 5.7 m, diameter 2.5 m, and capacity 8.7 tons and is constructed of 2219 Al alloy. The common bulkhead of Al-alloy-covered GFRP honeycomb, identified as the most critical component, has successfully completed extensive mechanical and thermal testing of both subscale and prototype models.

  18. Changes in exhaled breath condensate pH in healthy and asthmatic pregnant women.

    PubMed

    Eszes, Noémi; Bikov, András; Lázár, Zsófia; Bohács, Anikó; Müller, Veronika; Stenczer, Balázs; Rigó, János; Losonczy, György; Horváth, Ildikó; Tamási, Lilla

    2013-05-01

    Asthma is a common chronic disease complicating pregnancy with a risk for perinatal complications. Control of airway inflammation in the asthmatic pregnancy improves pregnancy outcomes. Our aim was to evaluate pH of exhaled breath condensate (EBC), a non-invasive method for the assessment of asthmatic airway inflammation, in healthy and asthmatic pregnancies. Cross-sectional study. Hungarian university clinics. Seventeen healthy pregnant women, 21 asthmatic pregnant women, 23 healthy non-pregnant women and 22 asthmatic non-pregnant women. EBC samples were collected using a portable condenser, EBC pH was measured after argon deaeration. EBC pH. EBC pH (mean ± SD) of healthy non-pregnant and asthmatic non-pregnant women was similar (7.75 ± 0.27 vs. 7.54 ± 0.57; p = 0.118), probably indicating an optimal control of airway inflammation in asthmatic women. On the other hand, EBC pH was higher in healthy pregnant women compared with healthy non-pregnant women (8.02 ± 0.43 vs. 7.75 ± 0.27; p = 0.017). Higher EBC pH accompanying healthy pregnancy was absent in asthmatic pregnant patients whose EBC pH was lower (7.65 ± 0.38) than that of healthy pregnant women (p = 0.006), and it was similar to that in asthmatic and healthy non-pregnant women (p = 0.470 and p = 0.300, respectively). The EBC pH in asthmatic pregnant women correlated positively with birthweight (r = 0.49, p = 0.047) and negatively with forced vital capacity (r = 0.45, p = 0.039). EBC pH was not related to blood pH. EBC pH is higher in healthy pregnant women but not in asthmatic pregnant women compared with data from healthy non-pregnant women, indicating that oxidative inflammatory processes induced by asthma may compromise the regulatory mechanisms causing alkaline pH in the airways during pregnancy. © 2013 The Authors Acta Obstetricia et Gynecologica Scandinavica © 2013 Nordic Federation of Societies of Obstetrics and Gynecology.

  19. Perfluorocarbon emulsions radiosensitise brain tumors in carbogen breathing mice with orthotopic GL261 gliomas

    PubMed Central

    Feldman, Lisa A.; Fabre, Marie-Sophie; Grasso, Carole; Reid, Dana; Broaddus, William C.; Lanza, Gregory M.; Spiess, Bruce D.; Garbow, Joel R.; McConnell, Melanie J.

    2017-01-01

    Background Tumour hypoxia limits the effectiveness of radiation therapy. Delivering normobaric or hyperbaric oxygen therapy elevates pO2 in both tumour and normal brain tissue. However, pO2 levels return to baseline within 15 minutes of stopping therapy. Aim To investigate the effect of perfluorocarbon (PFC) emulsions on hypoxia in subcutaneous and intracranial mouse gliomas and their radiosensitising effect in orthotopic gliomas in mice breathing carbogen (95%O2 and 5%CO2). Results PFC emulsions completely abrogated hypoxia in both subcutaneous and intracranial GL261 models and conferred a significant survival advantage orthotopically (Mantel Cox: p = 0.048) in carbogen breathing mice injected intravenously (IV) with PFC emulsions before radiation versus mice receiving radiation alone. Carbogen alone decreased hypoxia levels substantially and conferred a smaller but not statistically significant survival advantage over and above radiation alone. Conclusion IV injections of PFC emulsions followed by 1h carbogen breathing, radiosensitises GL261 intracranial tumors. PMID:28873460

  20. Hyperbaric nitrogen prolongs breath-holding time in humans.

    PubMed

    Morooka, H; Wakasugi, Y; Shimamoto, H; Shibata, O; Sumikawa, K

    2000-09-01

    Either an increase in PaCO(2) or a decrease in PaO(2), can affect respiratory stimulation through respiratory centers, thus influencing breath-holding time (BHT). This study was designed to determine whether and how hyperbaric air could influence BHT in comparison with hyperbaric oxygen in humans. We studied 36 healthy volunteers in a multiplace hyperbaric chamber. BHT, pulse oximeter, and transcutaneous carbon dioxide tension were measured at 1 and 2.8 atmosphere absolute (ATA) in two groups. Group A (n = 20) breathed air. Group O (n = 16) breathed oxygen with a face mask (5 L/min). BHTs were 108 +/- 28 s at 1.0 ATA and 230 +/- 71 s at 2.8 ATA in Group A, and 137 +/- 48 s at 1.0 ATA and 180 +/- 52 s at 2.8 ATA in Group O. Transcutaneous carbon dioxide tension in Group A (59 +/- 2 mm Hg) was higher than that in Group O (54 +/- 2 mm Hg) at the end of maximal breath-holding at 2.8 ATA. The prolongation of BHT in hyperbaric air is significantly greater than that in hyperbaric oxygen. Breath-holding time is significantly prolonged in hyperbaric air than it is in hyperbaric oxygen. The mechanism involves the anesthetic effect of nitrogen suppressing the suffocating feeling during breath-holding.

  1. Human breath metabolomics using an optimized noninvasive exhaled breath condensate sampler

    PubMed Central

    Zamuruyev, Konstantin O.; Aksenov, Alexander A.; Pasamontes, Alberto; Brown, Joshua F.; Pettit, Dayna R.; Foutouhi, Soraya; Weimer, Bart C.; Schivo, Michael; Kenyon, Nicholas J.; Delplanque, Jean-Pierre; Davis, Cristina E.

    2017-01-01

    Exhaled breath condensate (EBC) analysis is a developing field with tremendous promise to advance personalized, non-invasive health diagnostics as new analytical instrumentation platforms and detection methods are developed. Multiple commercially-available and researcher-built experimental samplers are reported in the literature. However, there is very limited information available to determine an effective breath sampling approach, especially regarding the dependence of breath sample metabolomic content on the collection device design and sampling methodology. This lack of an optimal standard procedure results in a range of reported results that are sometimes contradictory. Here, we present a design of a portable human EBC sampler optimized for collection and preservation of the rich metabolomic content of breath. The performance of the engineered device is compared to two commercially available breath collection devices: the RTube™ and TurboDECCS. A number of design and performance parameters are considered, including: condenser temperature stability during sampling, collection efficiency, condenser material choice, and saliva contamination in the collected breath samples. The significance of the biological content of breath samples, collected with each device, is evaluated with a set of mass spectrometry methods and was the primary factor for evaluating device performance. The design includes an adjustable mass-size threshold for aerodynamic filtering of saliva droplets from the breath flow. Engineering an inexpensive device that allows efficient collection of metalomic-rich breath samples is intended to aid further advancement in the field of breath analysis for non-invasive health diagnostic. EBC sampling from human volunteers was performed under UC Davis IRB protocol 63701-3 (09/30/2014-07/07/2017). PMID:28004639

  2. Tunable diode lasers application for fully automated absolute measurements of CO and CO2 concentrations in human breath

    NASA Astrophysics Data System (ADS)

    Moskalenko, Konstantin L.; Sobolev, Nikolai V.; Adamovskay, Inna A.; Stepanov, Eugene V.; Nadezhdinskii, Alexander I.; McKenna-Lawlor, Susan

    1994-01-01

    Measurements of carbon monoxide and carbon dioxide concentrations by registration of high resolution absorption spectra are described. A fully automated diode laser system developed to simultaneously measure CO and CO2, with sensitivity for CO up to 50 ppb and CO2 up to 0.1 vol%, is described. Calculation of CO and CO2 concentrations was carried out on the base of a priori date on strength and broadening coefficients of detected absorption lines. Test procedures of such diode laser systems are described. Possible reasons affected on accuracy and reliability of obtained data (e.g., the value of diode lasers spontaneous radiation, the stability of CO content in a cell, etc.) for absolute and relative calibration procedure are discussed. The physiological level of CO concentration in the breath of non smokers and smokers under different ambient conditions of CO concentrations in the atmosphere (in Moscow and in Maynooth) are compared. Recent results on statistical studies of the behavior of CO concentrations as a function of breath holding time are represented.

  3. Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failure.

    PubMed

    Pelosi, P; Solca, M; Ravagnan, I; Tubiolo, D; Ferrario, L; Gattinoni, L

    1996-07-01

    level, although at high pressure support the increase in work of breathing with heat and moisture exchangers was less evident. Gas exchange was unaffected by heat and moisture exchangers, as minute ventilation increased to compensate for the higher deadspace produced in the circuit by the insertion of heat and moisture exchangers. The tested heat and moisture exchangers should be used carefully in patients with acute respiratory failure during pressure-support ventilation, since these devices substantially increase minute ventilation, ventilatory drive, and work of breathing. However, an increase in pressure-support ventilation (5 to 10 cm H2O) may compensate for the increased work of breathing.

  4. Exercise in cold air and hydrogen peroxide release in exhaled breath condensate.

    PubMed

    Marek, E; Volke, J; Mückenhoff, K; Platen, P; Marek, W

    2013-01-01

    Athletes have changes in the lung epithelial cells caused by inhalation of cold and dry air. The exhaled breath condensate contains a number of mediators from the respiratory system and H(2)O(2) is described as a marker of airways inflammation. The aim of this study was to determine the influence of exercise combined with cold air on the H(2)O(2) release in the exhaled breath. Twelve males (23.1 ± 1.5 years) were randomly assigned at 2 different days (1 day rest) to perform a 50 min run (75-80% of their max. heart rate) under normal (N) laboratory (18.1 ± 1.1°C) or cold (C) field condition (-15.2 ± 3.1°C). Before and immediately after each run, the EBC was collected under laboratory conditions and was analyzed amperometrically. Prior to the two runs, H(2)O(2) concentrations were 145.0 ± 31.0 (N) and 160.0 ± 49.1 nmol/L (C) and theoretical release was 70.3 ± 37.1 (N) and 82.6 ± 27.1 pmol/min (C) (p > 0.05). After each run, H(2)O(2) concentration increased significantly to 388.0 ± 22.8 nmol/L (N) and 622.1 ± 44.2 nmol/L (C) (p < 0.05), along with an increase in the theoretical release: 249.2 ± 35.7 pmol/min (N) and 400.9 ± 35.7 pmol/min (C) (p < 0.05). We conclude that release of H(2)O(2) into the EBC takes place under both resting conditions and after exercise. The concentration and release of H(2)O(2) increased after exercise in cold air compared to resting and laboratory conditions, which points to an increase in inflammatory and oxidative stress.

  5. Chemiresistive Electronic Nose toward Detection of Biomarkers in Exhaled Breath.

    PubMed

    Moon, Hi Gyu; Jung, Youngmo; Han, Soo Deok; Shim, Young-Seok; Shin, Beomju; Lee, Taikjin; Kim, Jin-Sang; Lee, Seok; Jun, Seong Chan; Park, Hyung-Ho; Kim, Chulki; Kang, Chong-Yun

    2016-08-17

    Detection of gas-phase chemicals finds a wide variety of applications, including food and beverages, fragrances, environmental monitoring, chemical and biochemical processing, medical diagnostics, and transportation. One approach for these tasks is to use arrays of highly sensitive and selective sensors as an electronic nose. Here, we present a high performance chemiresistive electronic nose (CEN) based on an array of metal oxide thin films, metal-catalyzed thin films, and nanostructured thin films. The gas sensing properties of the CEN show enhanced sensitive detection of H2S, NH3, and NO in an 80% relative humidity (RH) atmosphere similar to the composition of exhaled breath. The detection limits of the sensor elements we fabricated are in the following ranges: 534 ppt to 2.87 ppb for H2S, 4.45 to 42.29 ppb for NH3, and 206 ppt to 2.06 ppb for NO. The enhanced sensitivity is attributed to the spillover effect by Au nanoparticles and the high porosity of villi-like nanostructures, providing a large surface-to-volume ratio. The remarkable selectivity based on the collection of sensor responses manifests itself in the principal component analysis (PCA). The excellent sensing performance indicates that the CEN can detect the biomarkers of H2S, NH3, and NO in exhaled breath and even distinguish them clearly in the PCA. Our results show high potential of the CEN as an inexpensive and noninvasive diagnostic tool for halitosis, kidney disorder, and asthma.

  6. Biomechanical interpretation of a free-breathing lung motion model

    NASA Astrophysics Data System (ADS)

    Zhao, Tianyu; White, Benjamin; Moore, Kevin L.; Lamb, James; Yang, Deshan; Lu, Wei; Mutic, Sasa; Low, Daniel A.

    2011-12-01

    The purpose of this paper is to develop a biomechanical model for free-breathing motion and compare it to a published heuristic five-dimensional (5D) free-breathing lung motion model. An ab initio biomechanical model was developed to describe the motion of lung tissue during free breathing by analyzing the stress-strain relationship inside lung tissue. The first-order approximation of the biomechanical model was equivalent to a heuristic 5D free-breathing lung motion model proposed by Low et al in 2005 (Int. J. Radiat. Oncol. Biol. Phys. 63 921-9), in which the motion was broken down to a linear expansion component and a hysteresis component. To test the biomechanical model, parameters that characterize expansion, hysteresis and angles between the two motion components were reported independently and compared between two models. The biomechanical model agreed well with the heuristic model within 5.5% in the left lungs and 1.5% in the right lungs for patients without lung cancer. The biomechanical model predicted that a histogram of angles between the two motion components should have two peaks at 39.8° and 140.2° in the left lungs and 37.1° and 142.9° in the right lungs. The data from the 5D model verified the existence of those peaks at 41.2° and 148.2° in the left lungs and 40.1° and 140° in the right lungs for patients without lung cancer. Similar results were also observed for the patients with lung cancer, but with greater discrepancies. The maximum-likelihood estimation of hysteresis magnitude was reported to be 2.6 mm for the lung cancer patients. The first-order approximation of the biomechanical model fit the heuristic 5D model very well. The biomechanical model provided new insights into breathing motion with specific focus on motion trajectory hysteresis.

  7. Portable Breathing Assembly

    NASA Image and Video Library

    2017-06-12

    In the Space Station Processing Facility at NASA's Kennedy Space Center in Florida, Jacobs Test and Operations Support Contract, or TOSC, technicians fill portable breathing apparatuses, or PBAS. The PBAs are to be use on board the International Space Staton to provide astronauts with breathable air in the event of a fire or other emergency situation.

  8. 21 CFR 862.1120 - Blood gases (PCO2, PO2) and blood pH test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood gases (PCO2, PO2) and blood pH test system. 862.1120 Section 862.1120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry...

  9. 21 CFR 862.1120 - Blood gases (PCO2, PO2) and blood pH test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood gases (PCO2, PO2) and blood pH test system. 862.1120 Section 862.1120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry...

  10. 21 CFR 862.1120 - Blood gases (PCO2, PO2) and blood pH test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood gases (PCO2, PO2) and blood pH test system. 862.1120 Section 862.1120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry...

  11. 21 CFR 862.1120 - Blood gases (PCO2, PO2) and blood pH test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood gases (PCO2, PO2) and blood pH test system. 862.1120 Section 862.1120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry...

  12. Liver diffusivity in healthy volunteers and patients with chronic liver disease: Comparison of breath-hold and free-breathing techniques

    PubMed Central

    Eatesam, Mamak; Noworolski, Susan M; Tien, Phyllis C; Nystrom, Michelle; Dodge, Jennifer L.; Merriman, Raphael B.; Qayyum, Aliya

    2011-01-01

    Purpose To compare liver ADC obtained with breath-hold and free-breathing diffusion weighted imaging (DWI) in healthy volunteers and patients with liver disease. Materials and Methods Twenty-eight subjects, 12 healthy volunteers and 16 patients (9 NAFLD, 7 chronic active HCV), underwent breath-hold (BH) and free-breathing (FB) DWI MRI at 1.5T. Pearson’s correlation coefficient was used to determine correlation while paired t-tests assessed differences between BH and FB ADC. Estimated bias was calculated using the Bland-Altman method. Results Liver ADC (×10−3 mm2/sec) was lower on BH for all groups (mean difference 0.36±0.20; p<0.01). ADC was higher in healthy volunteers (BH 1.80±0.18; FB 2.24±0.20) compared to NAFLD patients (BH 1.43±0.27; FB 1.78±0.28) (p<0.001) and HCV patients (BH 1.63±0.191; FB 1.88±0.12). Overall correlation between BH and FB ADC was (r =0.75), greatest in NAFLD (r =0.90) compared to the correlation in HCV (r =0.24) and healthy subjects (r =0.34). Bland-Altman plots did not show agreement in mean absolute difference and estimated bias between subjects. Conclusion Correlation between BH and FB liver ADC is moderate indicating that BH and FB should not be used interchangeably. Additionally, the lower ADC values in BH versus FB should be accounted for when comparing different liver DWI studies. PMID:22034200

  13. Colorimetric susceptibility testing for Aspergillus fumigatus: comparison of menadione-augmented 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide and Alamar blue tests.

    PubMed Central

    Jahn, B; Stüben, A; Bhakdi, S

    1996-01-01

    Two colorimetric methods that use Alamar Blue or 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) for assaying the in vitro activities of antifungal agents have been described. We report that both tests performed similarly when the antifungal activity of amphotericin B against Candida albicans was determined. However, only the MTT test generated interpretable data when Aspergillus fumigatus was used. PMID:8818910

  14. Volatile Biomarkers in Breath Associated With Liver Cirrhosis — Comparisons of Pre- and Post-liver Transplant Breath Samples

    PubMed Central

    Fernández del Río, R.; O'Hara, M.E.; Holt, A.; Pemberton, P.; Shah, T.; Whitehouse, T.; Mayhew, C.A.

    2015-01-01

    Background The burden of liver disease in the UK has risen dramatically and there is a need for improved diagnostics. Aims To determine which breath volatiles are associated with the cirrhotic liver and hence diagnostically useful. Methods A two-stage biomarker discovery procedure was used. Alveolar breath samples of 31 patients with cirrhosis and 30 healthy controls were mass spectrometrically analysed and compared (stage 1). 12 of these patients had their breath analysed after liver transplant (stage 2). Five patients were followed longitudinally as in-patients in the post-transplant period. Results Seven volatiles were elevated in the breath of patients versus controls. Of these, five showed statistically significant decrease post-transplant: limonene, methanol, 2-pentanone, 2-butanone and carbon disulfide. On an individual basis limonene has the best diagnostic capability (the area under a receiver operating characteristic curve (AUROC) is 0.91), but this is improved by combining methanol, 2-pentanone and limonene (AUROC curve 0.95). Following transplant, limonene shows wash-out characteristics. Conclusions Limonene, methanol and 2-pentanone are breath markers for a cirrhotic liver. This study raises the potential to investigate these volatiles as markers for early-stage liver disease. By monitoring the wash-out of limonene following transplant, graft liver function can be non-invasively assessed. PMID:26501124

  15. Voluntary control of breathing does not alter vagal modulation of heart rate

    NASA Technical Reports Server (NTRS)

    Patwardhan, A. R.; Evans, J. M.; Bruce, E. N.; Eckberg, D. L.; Knapp, C. F.

    1995-01-01

    Variations in respiratory pattern influence the heart rate spectrum. It has been suggested, hence, that metronomic respiration should be used to correctly assess vagal modulation of heart rate by using spectral analysis. On the other hand, breathing to a metronome has been reported to increase heart rate spectral power in the high- or respiratory frequency region; this finding has led to the suggestion that metronomic respiration enhances vagal tone or alters vagal modulation of heart rate. To investigate whether metronomic breathing complicates the interpretation of heart rate spectra by altering vagal modulation, we recorded the electrocardiogram and respiration from eight volunteers during three breathing trials of 10 min each: 1) spontaneous breathing (mean rate of 14.4 breaths/min); 2) breathing to a metronome at the rate of 15, 18, and 21 breaths/min for 2, 6, and 2 min, respectively; and 3) breathing to a metronome at the rate of 18 breaths/min for 10 min. Data were also collected from eight volunteers who breathed spontaneously for 20 min and breathed metronomically at each subject's mean spontaneous breathing frequency for 20 min. Results from the three 10-min breathing trials showed that heart rate power in the respiratory frequency region was smaller during metronomic breathing than during spontaneous breathing. This decrease could be explained fully by the higher breathing frequencies used during trials 2 and 3 of metronomic breathing. When the subjects breathed metronomically at each subject's mean breathing frequency, the heart rate powers during metronomic breathing were similar to those during spontaneous breathing. Our results suggest that vagal modulation of heart rate is not altered and vagal tone is not enhanced during metronomic breathing.

  16. Metabolic and ventilatory responses to submaximal and maximal exercise using different breathing assemblies.

    PubMed

    Evans, B W; Potteiger, J A

    1995-06-01

    This study compared ventilatory and metabolic responses during exercise using three breathing assemblies: mouthpiece/noseclip (BV); mouth/face mask (MM); and facemask (FM). Ten male runners completed three maximal treadmill tests with breathing assembly randomly assigned. Metabolic and ventilatory data were recorded every 15s, and heart rate (HR) and rating of perceived exertion (RPE) each min. No significant differences were found for treadmill run time, HRmax, respiratory exchange ratio (RER), and RPE, indicating similar efforts on all trials. No significant differences were found at maximal exercise for VO2 minute ventilation (VE), tidal volume (VT), and breathing frequency (f). At ventilatory threshold (TVENT), VO2, VE, and f were not significantly different. However, peak flow (PF) was significantly higher for BV than FM, and VT was significantly higher for BV than MM and FM. Results indicate alterations in ventilatory mechanics occur at TVENT, but type of breathing assembly does not significantly affect maximal values.

  17. Dark chocolate reduces endothelial dysfunction after successive breath-hold dives in cool water.

    PubMed

    Theunissen, Sigrid; Schumacker, Julie; Guerrero, François; Tillmans, Frauke; Boutros, Antoine; Lambrechts, Kate; Mazur, Aleksandra; Pieri, Massimo; Germonpré, Peter; Balestra, Costantino

    2013-12-01

    The aim of this study is to observe the effects of dark chocolate on endothelial function after a series of successive apnea dives in non-thermoneutral water. Twenty breath-hold divers were divided into two groups: a control group (8 males and 2 females) and a chocolate group (9 males and 1 female). The control group was asked to perform a series of dives to 20 m adding up to 20 min in the quiet diving pool of Conflans-Ste-Honorine (Paris, France), water temperature was 27 °C. The chocolate group performed the dives 1 h after ingestion of 30 g of dark chocolate. Flow-mediated dilatation (FMD), digital photoplethysmography, nitric oxide (NO), and peroxynitrite ONOO−) levels were measured before and after each series of breath-hold dives. A significant decrease in FMD was observed in the control group after the dives (95.28 ± 2.9 % of pre-dive values, p < 0.001) while it was increased in the chocolate group (104.1 ± 2.9 % of pre-dive values, p < 0.01). A decrease in the NO level was observed in the control group (86.76 ± 15.57 %, p < 0.05) whereas no difference was shown in the chocolate group (98.44 ± 31.86 %, p > 0.05). No differences in digital photoplethysmography and peroxynitrites were observed between before and after the dives. Antioxidants contained in dark chocolate scavenge free radicals produced during breath-hold diving. Ingestion of 30 g of dark chocolate 1 h before the dive can thus prevent endothelial dysfunction which can be observed after a series of breath-hold dives.

  18. Clinical comparison of a new manual toothbrush on breath volatile sulfur compounds.

    PubMed

    Williams, Malcolm I; Vazquez, Joe; Cummins, Diane

    2004-10-01

    The objective of this randomized, crossover study was to compare the effectiveness of a newly designed manual toothbrush (Colgate 360 degrees) to two commercially available manual toothbrushes (Oral-B Indicator and Oral-B CrossAction) and a battery-powered toothbrush (Crest SpinBrush PRO) for their ability to reduce overnight volatile sulfur compounds (VSC) associated with oral malodor. The study followed a four-period crossover design. Following a washout period, prospective subjects arrived at the testing facility without eating, drinking, or performing oral hygiene for baseline evaluation of breath VSC levels. For each phase of the study, subjects were given one of the test tooth-brushes and a tube of regular toothpaste to take home, and they were instructed to brush their teeth in their customary manner for 1 minute. When using the Colgate 360 degrees toothbrush, subjects were instructed to clean their tongue with the implement on the back of the brush head for 10 seconds. The following morning, subjects reported to the testing facility, again without performing oral hygiene, eating, or drinking, for the overnight evaluation. After a minimum 2-day washout period, subjects repeated the same regimen using the other toothbrushes. The levels of breath VSC were evaluated instrumentally using a gas chromatograph equipped with a flame photometric detector. Measurements were taken in duplicate and then averaged. The levels of VSC were expressed as parts per billion (ppb) in mouth air. Sixteen men and women completed the study. At baseline, the mean levels of VSC in mouth air for the 4 toothbrushes were 719.8 ppb+/-318.4 ppb, 592.8 ppb+/-264.6 ppb, 673.8 ppb+/-405.9 ppb, and 656.2 ppb+/-310.2 ppb for the Colgate 360 degrees, Oral-B Indicator, Crest SpinBrush PRO, and Oral-B CrossAction, respectively. Overnight, the mean breath VSC levels after using the four toothbrushes were lower than those observed at baseline. The respective mean levels of breath VSC were 266.5 ppb

  19. Identification of risk factors for pancreatic exocrine insufficiency after pancreaticoduodenectomy using a 13C-labeled mixed triglyceride breath test.

    PubMed

    Hirono, Seiko; Murakami, Yoshiaki; Tani, Masaji; Kawai, Manabu; Okada, Ken-ichi; Uemura, Kenichiro; Sudo, Takeshi; Hashimoto, Yasushi; Nakagawa, Naoya; Kondo, Naru; Yamaue, Hiroki

    2015-02-01

    There are only a few reports concerning long-term exocrine function after pancreaticoduodenectomy (PD), although the number of long-term survivors has increased. We assessed pancreatic exocrine function after PD in 189 patients to identify risk factors for pancreatic exocrine insufficiency. We evaluated patients' exocrine function by using the (13)C-labeled mixed triglyceride breath test, a noninvasive test feasible in outpatient service units. The present study included 99 patients that underwent pancreaticojejunostomy (PJ) at Wakayama Medical University Hospital and 90 patients that underwent pancreaticogastrostomy (PG) at Hiroshima University Hospital, the standard reconstruction techniques during PD at the respective hospitals. We also analyzed long-term morphological changes of remnant pancreas by computed tomography (main pancreatic duct dilation and parenchymal atrophy), nutritional status, and endocrine function. Independent risk factors for exocrine insufficiency after PD include hard pancreas (P = 0.003, odds ratio; 3.157) and PG reconstruction (P = 0.040, odds ratio; 2.321). Breath test results correlated significantly with post-operative morphological changes, nutritional status, and endocrine function. Atrophic changes of the remnant pancreas in the PG group were more severe than those in the PJ group. Furthermore, for patients with a soft pancreas, postoperative body weight changes, prognostic nutritional index, serum total protein levels as well as exocrine test were worse in the PG group, compared with the PJ group. Our results showed that PJ reconstruction might be superior to PG during PD, from the viewpoint of long-term pancreatic exocrine function, although further prospective studies are needed.

  20. Understanding overpressure in the FAA aerosol can test by C3H2F3Br (2-BTP)✩

    PubMed Central

    Linteris, Gregory Thomas; Babushok, Valeri Ivan; Pagliaro, John Leonard; Burgess, Donald Raymond; Manion, Jeffrey Alan; Takahashi, Fumiaki; Katta, Viswanath Reddy; Baker, Patrick Thomas

    2018-01-01

    Thermodynamic equilibrium calculations, as well as perfectly-stirred reactor (PSR) simulations with detailed reaction kinetics, are performed for a potential halon replacement, C3H2F3Br (2-BTP, C3H2F3Br, 2-Bromo-3,3,3-trifluoropropene), to understand the reasons for the unexpected enhanced combustion rather than suppression in a mandated FAA test. The high pressure rise with added agent is shown to depend on the amount of agent, and is well-predicted by an equilibrium model corresponding to stoichiometric reaction of fuel, oxygen, and agent. A kinetic model for the reaction of C3H2F3Br in hydrocarbon-air flames has been applied to understand differences in the chemical suppression behavior of C3H2F3Br vs. CF3Br in the FAA test. Stirred-reactor simulations predict that in the conditions of the FAA test, the inhibition effectiveness of C3H2F3Br at high agent loadings is relatively insensitive to the overall stoichiometry (for fuel-lean conditions), and the marginal inhibitory effect of the agent is greatly reduced, so that the mixture remains flammable over a wide range of conditions. Most important, the flammability of the agent-air mixtures themselves (when compressively preheated), can support low-strain flames which are much more difficult to extinguish than the easy-to extinguish, high-strain primary fireball from the impulsively released fuel mixture. Hence, the exothermic reaction of halogenated hydrocarbons in air should be considered in other situations with strong ignition sources and low strain flows, especially at preheated conditions. PMID:29628525

  1. Validation of the Natus CO-Stat End Tidal Breath Analyzer in children and adults.

    PubMed

    Vreman, H J; Wong, R J; Harmatz, P; Fanaroff, A A; Berman, B; Stevenson, D K

    1999-12-01

    The performance of a point-of-care, noninvasive end tidal breath carbon monoxide analyzer (CO-Stat End Tidal Breath Analyzer, Natus Medical Inc.) that also reports end tidal carbon dioxide (ETCO2) and respiratory rate (RR), was compared to established, marketed (predicate) devices in children (n = 39) and adults (n = 48) who are normal or at-risk of elevated CO excretion. Concentrations of end tidal breath CO (ETCO), room air CO, ETCO corrected for inhaled CO (ETCOc), ETCO2, and RR were measured with the CO-Stat analyzer and the data compared to those obtained from the same subjects using the Vitalograph BreathCO monitor (Vitalograph, Inc.) for ETCOc and the Pryon CO2 monitor (SC210 and SC300, Pryon Corp) for ETCO2 and RR. Adults and children were studied at three medical centers. The data were analyzed by paired t-tests and linear regression. Bias and imprecision between the CO-Stat analyzer and the predicate devices was calculated by the method of Bland and Altman. Paired t-tests, performed on the three parameters measured with the CO-Stat analyzer and predicate devices showed that only the ETCOc values in the adults and the ETCO2 values in the children were significantly different (lower, p < or = 0.0001, and higher, p < or = 0.0001, respectively). The mean bias and imprecision of the CO-Stat analyzer for adult ETCOc and children ETCO2 measurements were -0.9 +/- 1.2 ppm and 0.4 +/- 0.6%, respectively. Linear regression analysis for the ETCOc results in children and adults had a high degree of correlation (r = 0.91 and 0.98, respectively). We conclude that in a clinical environment the Natus CO-Stat End Tidal Breath Analyzer performs at least as well as predicate devices for the measurements of ETCOc, ETCO2, and RR.

  2. A rapid non invasive L-DOPA-¹³C breath test for optimally suppressing extracerebral AADC enzyme activity - toward individualizing carbidopa therapy in Parkinson’s disease.

    PubMed

    Modak, Anil; Durso, Raymon; Josephs, Ephraim; Rosen, David

    2012-01-01

    Peripheral carbidopa (CD) levels directly impact on central dopamine (DA) production in Parkinson disease (PD) through extracerebral inhibition of dopa decarboxylase (AADC) resulting in an increase in levodopa (LD) bioavailability. Recent data suggests that higher CD doses than those presently used in PD treatment may result in improved clinical response. Optimizing CD doses in individual patients may, therefore, result in ideal individualized treatment. A single center, randomized, double-blind study was carried out recruiting 5 Parkinson’s disease (PD) patients already on LD/CD and 1 treatment näve PD patient using stable isotope labeled LD-1-¹³C as a substrate for a noninvasive breath test to evaluate individual AADC enzyme activity. Each patient was studied five times, receiving 200 mg LD-¹³C at each visit along with one of five randomized CD doses (0, 25, 50, 100 and 200 mg). The metabolite ¹³CO₂ in breath was measured for evaluating AADC enzyme activity and plasma metabolite levels for LD-¹³C and homovanillic acid (HVA) were measured for 4 hours. HVA in plasma and ¹³CO₂ in breath are metabolic products of LD. We found a significant positive correlation of ¹³CO₂ DOB AUC0-240 with serum HVA AUC0-240 following the oral dose of LD-1-¹³C for all 5 doses of CD (r² = 0.9378). With increasing inhibition of AADC enzyme activity with CD, we observed an increase in the plasma concentration of LD.We found an inverse correlation of the 13CO2 DOB AUC with serum LD-¹³C AUC. Our studies indicate the optimal dose of CD for maximal suppression of AADC enzyme activity can be determined for each individual from ¹³CO₂ generation in breath. The LD-breath test can be a useful noninvasive diagnostic tool for evaluation of AADC enzyme activity using the biomarker ¹³CO₂ in breath, a first step in personalizing CD doses for PD patients.

  3. NICMOS Focus and HST Breathing

    NASA Astrophysics Data System (ADS)

    Suchkov, A.; Hershey, J.

    1998-09-01

    The program 7608 monitored on a biweekly basis NICMOS camera foci from June 9, 1997, through February 18, 1998. Each of the biweekly observations included 17 measurements of focus position (focus sweeps), individually for each of the three cameras. The measurements for camera 1 and camera 3 foci covered one or two HST orbital periods. Comparison of these measurements with the predictions of the three OTA focus breathing models has shown the following. (1). Focus variations seen in NICMOS focus sweeps correlate well with the OTA focus thermal breathing as predicted by breathing models (“4- temperature”, “full-temperature”, and “attitude” models). Thus they can be attributed mostly to the HST orbital temperature variation. (2). The amount of breathing (breathing amplitude) has been found to be on average larger in the first orbit after a telescope slew to a new target. This is explained as being due to additional thermal perturbations caused by the change in the HST attitude as the telescope repoints to a new target. (3). In the first orbit, the amount of focus change predicted by the 4-temperature model is about the same as that seen in the focus sweeps data (breathing scale factor ~1). However the full-temperature model predicts a two times smaller breathing amplitude (breathing scale factor ~1.7). This suggests that the light shield temperatures are more responsive to the attitude change than temperatures from the other temperature sensors. The results of this study may help to better understand the HST thermal cycles and to improve the models describing the impact of those on both the OTA and NICMOS focus.

  4. Chemoresponsiveness and breath physiology in anosmia.

    PubMed

    Mazzatenta, Andrea; Pokorski, Mieczyslaw; Montinaro, Danilo; Di Giulio, Camillo

    2015-01-01

    Anosmia is a model to study the interaction among chemoreception systems. In the head injury, the traumatic irreversible anosmia caused by damage to olfactory nerve fibers and brain regions is of enviable research interest. In this study, psychophysiological tests for a comprehensive assessment of olfactory function were utilized to investigate anosmia, together with a new technique based on the breath real-time monitoring of volatile organic compounds (VOCs). We applied the breath and VOCs analysis to investigate chemoresponsiveness in the long-term irreversible post-traumatic anosmia.

  5. Residual gas analyzer mass spectrometry for human breath analysis: a new tool for the non-invasive diagnosis of Helicobacter pylori infection.

    PubMed

    Maity, Abhijit; Banik, Gourab D; Ghosh, Chiranjit; Som, Suman; Chaudhuri, Sujit; Daschakraborty, Sunil B; Ghosh, Shibendu; Ghosh, Barnali; Raychaudhuri, Arup K; Pradhan, Manik

    2014-03-01

    A residual gas analyzer (RGA) coupled with a high vacuum chamber is described for the non-invasive diagnosis of the Helicobacter pylori (H. pylori) infection through ¹³C-urea breath analysis. The present RGA-based mass spectrometry (MS) method is capable of measuring high-precision ¹³CO₂ isotope enrichments in exhaled breath samples from individuals harboring the H. pylori infection. The system exhibited 100% diagnostic sensitivity, and 93% specificity alongside positive and negative predictive values of 95% and 100%, respectively, compared with invasive endoscopy-based biopsy tests. A statistically sound diagnostic cut-off value for the presence of H. pylori was determined to be 3.0‰ using a receiver operating characteristic curve analysis. The diagnostic accuracy and validity of the results are also supported by optical off-axis integrated cavity output spectroscopy measurements. The δ¹³(DOB)C‰ values of both methods correlated well (R² = 0.9973 at 30 min). The RGA-based instrumental setup described here is simple, robust, easy-to-use and more portable and cost-effective compared to all other currently available detection methods, thus making it a new point-of-care medical diagnostic tool for the purpose of large-scale screening of the H. pylori infection in real time. The RGA-MS technique should have broad applicability for ¹³C-breath tests in a wide range of biomedical research and clinical diagnostics for many other diseases and metabolic disorders.

  6. Slow Breathing and Hypoxic Challenge: Cardiorespiratory Consequences and Their Central Neural Substrates

    PubMed Central

    Critchley, Hugo D.; Nicotra, Alessia; Chiesa, Patrizia A.; Nagai, Yoko; Gray, Marcus A.; Minati, Ludovico; Bernardi, Luciano

    2015-01-01

    Controlled slow breathing (at 6/min, a rate frequently adopted during yoga practice) can benefit cardiovascular function, including responses to hypoxia. We tested the neural substrates of cardiorespiratory control in humans during volitional controlled breathing and hypoxic challenge using functional magnetic resonance imaging (fMRI). Twenty healthy volunteers were scanned during paced (slow and normal rate) breathing and during spontaneous breathing of normoxic and hypoxic (13% inspired O2) air. Cardiovascular and respiratory measures were acquired concurrently, including beat-to-beat blood pressure from a subset of participants (N = 7). Slow breathing was associated with increased tidal ventilatory volume. Induced hypoxia raised heart rate and suppressed heart rate variability. Within the brain, slow breathing activated dorsal pons, periaqueductal grey matter, cerebellum, hypothalamus, thalamus and lateral and anterior insular cortices. Blocks of hypoxia activated mid pons, bilateral amygdalae, anterior insular and occipitotemporal cortices. Interaction between slow breathing and hypoxia was expressed in ventral striatal and frontal polar activity. Across conditions, within brainstem, dorsal medullary and pontine activity correlated with tidal volume and inversely with heart rate. Activity in rostroventral medulla correlated with beat-to-beat blood pressure and heart rate variability. Widespread insula and striatal activity tracked decreases in heart rate, while subregions of insular cortex correlated with momentary increases in tidal volume. Our findings define slow breathing effects on central and cardiovascular responses to hypoxic challenge. They highlight the recruitment of discrete brainstem nuclei to cardiorespiratory control, and the engagement of corticostriatal circuitry in support of physiological responses that accompany breathing regulation during hypoxic challenge. PMID:25973923

  7. Bayesian modelling of lung function data from multiple-breath washout tests.

    PubMed

    Mahar, Robert K; Carlin, John B; Ranganathan, Sarath; Ponsonby, Anne-Louise; Vuillermin, Peter; Vukcevic, Damjan

    2018-05-30

    Paediatric respiratory researchers have widely adopted the multiple-breath washout (MBW) test because it allows assessment of lung function in unsedated infants and is well suited to longitudinal studies of lung development and disease. However, a substantial proportion of MBW tests in infants fail current acceptability criteria. We hypothesised that a model-based approach to analysing the data, in place of traditional simple empirical summaries, would enable more efficient use of these tests. We therefore developed a novel statistical model for infant MBW data and applied it to 1197 tests from 432 individuals from a large birth cohort study. We focus on Bayesian estimation of the lung clearance index, the most commonly used summary of lung function from MBW tests. Our results show that the model provides an excellent fit to the data and shed further light on statistical properties of the standard empirical approach. Furthermore, the modelling approach enables the lung clearance index to be estimated by using tests with different degrees of completeness, something not possible with the standard approach. Our model therefore allows previously unused data to be used rather than discarded, as well as routine use of shorter tests without significant loss of precision. Beyond our specific application, our work illustrates a number of important aspects of Bayesian modelling in practice, such as the importance of hierarchical specifications to account for repeated measurements and the value of model checking via posterior predictive distributions. Copyright © 2018 John Wiley & Sons, Ltd.

  8. Human breath metabolomics using an optimized non-invasive exhaled breath condensate sampler.

    PubMed

    Zamuruyev, Konstantin O; Aksenov, Alexander A; Pasamontes, Alberto; Brown, Joshua F; Pettit, Dayna R; Foutouhi, Soraya; Weimer, Bart C; Schivo, Michael; Kenyon, Nicholas J; Delplanque, Jean-Pierre; Davis, Cristina E

    2016-12-22

    Exhaled breath condensate (EBC) analysis is a developing field with tremendous promise to advance personalized, non-invasive health diagnostics as new analytical instrumentation platforms and detection methods are developed. Multiple commercially-available and researcher-built experimental samplers are reported in the literature. However, there is very limited information available to determine an effective breath sampling approach, especially regarding the dependence of breath sample metabolomic content on the collection device design and sampling methodology. This lack of an optimal standard procedure results in a range of reported results that are sometimes contradictory. Here, we present a design of a portable human EBC sampler optimized for collection and preservation of the rich metabolomic content of breath. The performance of the engineered device is compared to two commercially available breath collection devices: the RTube ™ and TurboDECCS. A number of design and performance parameters are considered, including: condenser temperature stability during sampling, collection efficiency, condenser material choice, and saliva contamination in the collected breath samples. The significance of the biological content of breath samples, collected with each device, is evaluated with a set of mass spectrometry methods and was the primary factor for evaluating device performance. The design includes an adjustable mass-size threshold for aerodynamic filtering of saliva droplets from the breath flow. Engineering an inexpensive device that allows efficient collection of metalomic-rich breath samples is intended to aid further advancement in the field of breath analysis for non-invasive health diagnostic. EBC sampling from human volunteers was performed under UC Davis IRB protocol 63701-3 (09/30/2014-07/07/2017).

  9. Individual breathing reactions measured in hemoglobin by hydrogen exchange methods.

    PubMed Central

    Englander, S W; Calhoun, D B; Englander, J J; Kallenbach, N R; Liem, R K; Malin, E L; Mandal, C; Rogero, J R

    1980-01-01

    Protein hydrogen exchange is generally believed to register some aspects of internal protein dynamics, but the kind of motion at work is not clear. Experiments are being done to identify the determinants of protein hydrogen exchange and to distinguish between local unfolding and accessibility-penetration mechanisms. Results with small molecules, polynucleotides, and proteins demonstrate that solvent accessibility is by no means sufficient for fast exchange. H-exchange slowing is quite generally connected with intramolecular H-bonding, and the exchange process depends pivotally on transient H-bond cleavage. At least in alpha-helical structures, the cooperative aspect of H-bond cleavage must be expressed in local unfolding reactions. Results obtained by use of a difference hydrogen exchange method appear to provide a direct measurement of transient, cooperative, local unfolding reactions in hemoglobin. The reality of these supposed coherent breathing units is being tested by using the difference H-exchange approach to tritium label the units one at a time and then attempting to locate the tritium by fragmenting the protein, separating the fragments, and testing them for label. Early results demonstrate the feasibility of this approach. PMID:7248462

  10. Exchange coupling transformations in Cu (II) heterospin complexes of “breathing crystals” under structural phase transitions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morozov, Vitaly A.; Petrova, Marina V.; Lukzen, Nikita N., E-mail: luk@tomo.nsc.ru

    2015-08-15

    Family of “breathing crystals” is the polymer-chain complexes of Cu(hfac){sub 2} with nitroxides. The polymer chains consist of one-, two- or three-spin clusters. The “breathing crystals” experience simultaneous magnetic and Jahn-Teller type structural phase transitions with change of total cluster spin and drastic change of bond lengths (ca. 10-12%). For the first time the intra-cluster magnetic couplings in ”breathing crystals” have been calculated both by band structure methods GGA + U and hybrid DFT (B3LYP and PBE0) for the isolated exchange clusters. The temperature dependence of the magnetic coupling constant was calculated for two polymer-chain compounds of the “breathing crystal”more » family - C{sub 21}H{sub 19}CuF{sub 12}N{sub 4}O{sub 6} with the chains containing two-spin clusters and C{sub 22}H{sub 21}CuF{sub 12}N{sub 4}O{sub 6} with the chains of alternating three-spin clusters and one-spin sites. It was found that adding a Hubbard-like parameter not only to the copper 3d electrons but also to the oxygen 2p electrons (GGA + U{sub d} + U{sub p} approach) results in an improved description of exchange coupling in the “breathing crystal” compounds. At the same time treatment of the isolated clusters by a large basis hybrid DFT with high computational cost provides a similar quality fit of the experimental magneto-chemical data as that for the GGA + U{sub d} + U{sub p} band structure calculation scheme. Our calculations also showed that in spite of the abrupt transformation of the magnetic coupling constant under the phase transition, the band gap in the “breathing crystals” remains about the same value with temperature decrease.« less

  11. Breath analysis with broadly tunable quantum cascade lasers.

    PubMed

    Wörle, Katharina; Seichter, Felicia; Wilk, Andreas; Armacost, Chris; Day, Tim; Godejohann, Matthias; Wachter, Ulrich; Vogt, Josef; Radermacher, Peter; Mizaikoff, Boris

    2013-03-05

    With the availability of broadly tunable external cavity quantum cascade lasers (EC-QCLs), particularly bright mid-infrared (MIR; 3-20 μm) light sources are available offering high spectral brightness along with an analytically relevant spectral tuning range of >2 μm. Accurate isotope ratio determination of (12)CO2 and (13)CO2 in exhaled breath is of critical importance in the field of breath analysis, which may be addressed via measurements in the MIR spectral regime. Here, we combine for the first time an EC-QCL tunable across the (12)CO2/(13)CO2 spectral band with a miniaturized hollow waveguide gas cell for quantitatively determining the (12)CO2/(13)CO2 ratio within the exhaled breath of mice. Due to partially overlapping spectral features, these studies are augmented by appropriate multivariate data evaluation and calibration techniques based on partial least-squares regression along with optimized data preprocessing. Highly accurate determinations of the isotope ratio within breath samples collected from a mouse intensive care unit validated via hyphenated gas chromatography-mass spectrometry confirm the viability of IR-HWG-EC-QCL sensing techniques for isotope-selective exhaled breath analysis.

  12. Diacetyl and 2,3-pentanedione in breathing zone and area air during large-scale commercial coffee roasting, blending and grinding processes.

    PubMed

    McCoy, Michael J; Hoppe Parr, Kimberly A; Anderson, Kim E; Cornish, Jim; Haapala, Matti; Greivell, John

    2017-01-01

    Recently described scientific literature has identified the airborne presence of 2,3-butanedione (diacetyl) and 2,3-pentanedione at concentrations approaching or potentially exceeding the current American Conference of Industrial Hygienists' (ACGIH) Threshold Limit Values (TLVs) at commercial coffee roasting and production facilities. Newly established National Institutes of Occupational Safety and Health (NIOSH) Recommended Exposure Limits for diacetyl and 2,3-pentanedione are even more conservative. Chronic exposure to these alpha-diketones at elevated airborne concentrations has been associated with lung damage, specifically bronchiolitis obliterans, most notably in industrial food processing facilities. Workers at a large commercial coffee roaster were monitored for both eight-hour and task-based, short-term, 15-min sample durations for airborne concentrations of these alpha-diketones during specific work processes, including the coffee bean roasting, blending and grinding processes, during two separate 8-h work periods. Additionally, the authors performed real-time Fourier transform infrared spectroscopy (FTIR) analysis of the workers' breathing zone as well as the area workplace air for the presence of organic compounds to determine the sources, as well as quantitate and identify various organic compounds proximal to the roasting and grinding processes. Real-time FTIR measurements provided both the identification and quantitation of diacetyl and 2,3-pentanedione, as well as other organic compounds generated during coffee bean roasting and grinding operations. Airborne concentrations of diacetyl in the workers' breathing zone, as eight-hour time-weighted averages were less than the ACGIH TLVs for diacetyl, while concentrations of 2,3-pentanedione were below the limit of detection in all samples. Short-term breathing zone samples revealed airborne concentrations for diacetyl that exceeded the ACGIH short-term exposure limit of 0.02 parts per million (ppm) in

  13. Passive in-vehicle driver breath alcohol detection using advanced sensor signal acquisition and fusion.

    PubMed

    Ljungblad, Jonas; Hök, Bertil; Allalou, Amin; Pettersson, Håkan

    2017-05-29

    The research objective of the present investigation is to demonstrate the present status of passive in-vehicle driver breath alcohol detection and highlight the necessary conditions for large-scale implementation of such a system. Completely passive detection has remained a challenge mainly because of the requirements on signal resolution combined with the constraints of vehicle integration. The work is part of the Driver Alcohol Detection System for Safety (DADSS) program aiming at massive deployment of alcohol sensing systems that could potentially save thousands of American lives annually. The work reported here builds on earlier investigations, in which it has been shown that detection of alcohol vapor in the proximity of a human subject may be traced to that subject by means of simultaneous recording of carbon dioxide (CO 2 ) at the same location. Sensors based on infrared spectroscopy were developed to detect and quantify low concentrations of alcohol and CO 2 . In the present investigation, alcohol and CO 2 were recorded at various locations in a vehicle cabin while human subjects were performing normal in-step procedures and driving preparations. A video camera directed to the driver position was recording images of the driver's upper body parts, including the face, and the images were analyzed with respect to features of significance to the breathing behavior and breath detection, such as mouth opening and head direction. Improvement of the sensor system with respect to signal resolution including algorithm and software development, and fusion of the sensor and camera signals was successfully implemented and tested before starting the human study. In addition, experimental tests and simulations were performed with the purpose of connecting human subject data with repeatable experimental conditions. The results include occurrence statistics of detected breaths by signal peaks of CO 2 and alcohol. From the statistical data, the accuracy of breath alcohol

  14. Automatic Recognition of Breathing Route During Sleep Using Snoring Sounds

    NASA Astrophysics Data System (ADS)

    Mikami, Tsuyoshi; Kojima, Yohichiro

    This letter classifies snoring sounds into three breathing routes (oral, nasal, and oronasal) with discriminant analysis of the power spectra and k-nearest neighbor method. It is necessary to recognize breathing route during snoring, because oral snoring is a typical symptom of sleep apnea but we cannot know our own breathing and snoring condition during sleep. As a result, about 98.8% classification rate is obtained by using leave-one-out test for performance evaluation.

  15. The Effect of Breathing Exercises on the Nocturnal Enuresis in the Children with the Sleep-Disordered Breathing

    PubMed Central

    Khaleghipour, Shahnaz; Masjedi, Mohsen; Kelishadi, Roya

    2013-01-01

    Background The nocturnal enuresis is one of the most common complaints of childhood. Upper airway obstruction and nocturnal snoring affect the nocturnal enuresis in children. Objectives The aim of this study was to investigate the effects of breathing exercises on the nocturnal enuresis in the children with the sleep-disordered breathing. Patients and Methods This study was conducted in year of 2011 by a semi-experimental design with the control group among 40 children, aged 6 - 12 years, who had the nocturnal enuresis. Participants were examined based on the criteria of nocturnal enuresis, oral breathing, and nocturnal snoring. Subsequently, they were randomly assigned to the case and control groups. In the case group, the breathing exercises were performed for 45 minutes, and were pursued for four weeks in the morning following and prior to sleeping, and subsequently the arterial blood gases were measured and the frequency of enuresis and the respiratory rates (RR) were recorded. Results After intervention the means of PaCO2 and RR in the control group were significantly higher than the case group (P < 0.0001). Likewise, O2sat, PaO2 in the case group were higher than the control group (P < 0.0001). The nocturnal enuresis decreased significantly in the case group, compared to the control group (P < 0.0001). Conclusions This study suggests that the breathing exercises may reduce the frequency of nocturnal enuresis in the patients with the oral breathing and nocturnal snore. The clinical implications of these findings should be verified in the future longitudinal studies. PMID:24719691

  16. Patients' experiences of breathing retraining for asthma: a qualitative process analysis of participants in the intervention arms of the BREATHE trial.

    PubMed

    Arden-Close, Emily; Yardley, Lucy; Kirby, Sarah; Thomas, Mike; Bruton, Anne

    2017-10-05

    , interviewed 16 people about their experiences in a trial that tested breathing retraining exercises delivered by DVD or face-to-face sessions with a respiratory physiotherapist. Overwhelmingly, trial participants reported that breathing retraining sessions gave them greater control over their symptoms, helped them relax, improved their quality of life and reduced the need for medications. Some participants who received DVD instruction said they had trouble mastering the techniques, and many in both groups found it hard to find time to practice the exercises. Overall, however, patients were positive about the experience. The authors conclude that breathing exercises are likely to be a well-received method of asthma management.

  17. Chest physiotherapy and breathing exercises for cardiac surgery patients in Sweden--a national survey of practice.

    PubMed

    Westerdahl, E; Olsén, M Fagevik

    2011-06-01

    Various chest physiotherapy techniques are recommended after cardiac surgery around the world. There is limited published data on what breathing exercises actually are recommended to patients after surgery in Europe. The aim of this national survey was to establish the current practice of chest physiotherapy and breathing exercises for adult patients following cardiac surgery in Sweden. A postal questionnaire was sent to a total population sample of 33 Swedish physiotherapists working at the departments of cardiothoracic surgery in December 2007 and January 2008. In total, 29 replies (88%) were received. Seven male and twenty two female physiotherapists completed the questionnaire. All physiotherapists instructed, on a regular basis, the cardiac surgery patients to perform post-operative breathing exercises. Positive expiratory pressure (PEP) breathing was routinely used as the first choice for treatment by 22 (83%) of the physiotherapists. Expiratory pressures used varied between 2 and 20 cm H2O. Recommended frequency and duration of the exercises varied from 4 to 30 breaths hourly during the daytime in the first post-operative days. All physiotherapists provided coughing support to the patients. Recommendations to continue breathing exercises after discharge varied from not at all up to 3 months after surgery. Breathing exercises are regularly prescribed during the initial post-operative days after cardiac surgery in Sweden. Hourly deep breathing exercises performed with or without a PEP device were reported to be first choice treatments during the hospital stay. Instructions concerning how long patients should continue the exercises after discharge varied notably.

  18. Nasal versus face mask for multiple-breath washout technique in preterm infants.

    PubMed

    Schulzke, S M; Deeptha, K; Sinhal, S; Baldwin, D N; Pillow, J J

    2008-09-01

    The large dead space associated with face masks might impede the accuracy and feasibility of multiple-breath washout (MBW) measurements in small infants. We asked if a low dead space nasal mask would provide measurements of resting lung volume and ventilation inhomogeneity comparable to those obtained with a face mask, when using the MBW technique. Unsedated preterm infants breathing without mechanical assistance and weighing between 1.50 and 2.49 kg were studied. Paired MBW tests with nasal and face masks were obtained using sulphur hexafluoride (SF(6)) as the tracer gas. The order of mask application was quasi-randomized. Bland-Altman method and intraclass correlation coefficient were used to analyze outcomes. Measurements were obtained in 20 infants with a mean (SD) postmenstrual age of 36 (1.4) w and a test weight of 2.0 (0.3) kg. The mean difference (95% CI) for nasal vs. face mask was -3.2 breaths/min (-6.2, -0.1 breaths/min) for respiratory rate, -1.0 ml/kg (-2.3, 0.3 ml/kg) for lung volume, 0.6 (0.1, 1.1) for lung clearance index, 0.2 (0.1, 0.3) for first to zeroeth moment ratio and 1.33 (0.6, 2.4) for second to zeroeth moment ratio. Paired measurements of lung volume showed acceptable agreement and good correlation, but there was poor agreement and poor correlation between indices of ventilation inhomogeneity obtained with the two masks. Functional dead space of the nasal mask was similar to that of the face mask despite its smaller water displacement volume. During MBW in infants below 2.5 kg body weight, a nasal mask results in comparable lung volume measurements. Indices of ventilation inhomogeneity may not be directly comparable using masks with different dead space. (c) 2008 Wiley-Liss, Inc.

  19. Prediction of breast cancer risk with volatile biomarkers in breath.

    PubMed

    Phillips, Michael; Cataneo, Renee N; Cruz-Ramos, Jose Alfonso; Huston, Jan; Ornelas, Omar; Pappas, Nadine; Pathak, Sonali

    2018-03-23

    Human breath contains volatile organic compounds (VOCs) that are biomarkers of breast cancer. We investigated the positive and negative predictive values (PPV and NPV) of breath VOC biomarkers as indicators of breast cancer risk. We employed ultra-clean breath collection balloons to collect breath samples from 54 women with biopsy-proven breast cancer and 124 cancer-free controls. Breath VOCs were analyzed with gas chromatography (GC) combined with either mass spectrometry (GC MS) or surface acoustic wave detection (GC SAW). Chromatograms were randomly assigned to a training set or a validation set. Monte Carlo analysis identified significant breath VOC biomarkers of breast cancer in the training set, and these biomarkers were incorporated into a multivariate algorithm to predict disease in the validation set. In the unsplit dataset, the predictive algorithms generated discriminant function (DF) values that varied with sensitivity, specificity, PPV and NPV. Using GC MS, test accuracy = 90% (area under curve of receiver operating characteristic in unsplit dataset) and cross-validated accuracy = 77%. Using GC SAW, test accuracy = 86% and cross-validated accuracy = 74%. With both assays, a low DF value was associated with a low risk of breast cancer (NPV > 99.9%). A high DF value was associated with a high risk of breast cancer and PPV rising to 100%. Analysis of breath VOC samples collected with ultra-clean balloons detected biomarkers that accurately predicted risk of breast cancer.

  20. Hypoxemia, hypercapnia, and breathing pattern in patients with chronic obstructive pulmonary disease.

    PubMed

    Parot, S; Miara, B; Milic-Emili, J; Gautier, H

    1982-11-01

    The results of lung function tests (total and functional residual capacities, residual volume/total lung capacity ratio, forced expiratory volume in one second) breathing patterns and arterial PO2 and PCO2 were studied in 651 ambulatory male patients with chronic obstructive pulmonary disease, functionally and clinically stable. Function tests were only loosely correlated with gas tensions: abnormalities in mechanics and in gas exchange are not necessarily related. In patients matched for the degree of obstruction, the breathing pattern depended upon both PaO2 and PaCO2. Isolated hypoxemia was accompanied by increased respiratory frequency without any variation in tidal volume: this suggests that the chemoreceptive systems still responded to changes in PaO2. Isolated hypercapnia was accompanied by a decrease in tidal volume and an increase in respiratory frequency. Consequently, the dead space/tidal volume ratio increased, leading to a drop in alveolar ventilation and to CO2 retention.

  1. Mineralization of Basalts in the CO 2-H 2O-H 2S System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schaef, Herbert T.; McGrail, B. Peter; Owen, Antionette T.

    2013-05-10

    Basalt samples representing five different formations were immersed in water equilibrated with supercritical carbon dioxide containing 1% hydrogen sulfide (H2S) at reservoir conditions (100 bar, 90°C) for up to 3.5 years. Surface coatings in the form of pyrite and metal cation substituted carbonates were identified as reaction products associated with all five basalts. In some cases, high pressure tests contained excess H2S, which produced the most corroded basalts and largest amount of secondary products. In comparison, tests containing limited amounts of H2S appeared least reacted with significantly less concentrations of reaction products. In all cases, pyrite appeared to precede carbonation,more » and in some instances, was observed in the absence of carbonation such as in cracks, fractures, and within the porous glassy mesostasis. Armoring reactions from pyrite surface coatings observed in earlier shorter duration tests were found to be temporary with carbonate mineralization observed with all the basalts tested in these long duration experiments. Geochemical simulations conducted with the geochemical code EQ3/6 accurately predicted early pyrite precipitation followed by formation of carbonates. Reactivity with H2S was correlated with measured Fe(II)/Fe(III) ratios in the basalts with more facile pyrite formation occurring with basalts containing more Fe(III) phases. These experimental and modeling results confirm potential for long term sequestration of acid gas mixtures in continental flood basalt formations.« less

  2. Non-invasive 13C-glucose breath test using residual gas analyzer-mass spectrometry: a novel tool for screening individuals with pre-diabetes and type 2 diabetes.

    PubMed

    Ghosh, Chiranjit; Maity, Abhijit; Banik, Gourab D; Som, Suman; Chakraborty, Arpita; Selvan, Chitra; Ghosh, Shibendu; Ghosh, Barnali; Chowdhury, Subhankar; Pradhan, Manik

    2014-09-01

    We report, for the first time, the clinical feasibility of a novel residual gas analyzer mass spectrometry (RGA-MS) method for accurate evaluation of the (13)C-glucose breath test ((13)C-GBT) in the diagnosis of pre-diabetes (PD) and type 2 diabetes mellitus (T2D). In T2D or PD, glucose uptake is impaired and results in blunted isotope enriched (13)CO2 production in exhaled breath samples. Using the Receiver operating characteristics (ROC) curve analysis, an optimal diagnostic cut-off point of the (13)CO2/(12)CO2 isotope ratios expressed as the delta-over-baseline (DOB) value, was determined to be δDOB(13)C‰ = 28.81‰ for screening individuals with non-diabetes controls (NDC) and pre-diabetes (PD), corresponding to a sensitivity of 100% and specificity of 94.4%. We also determined another optimal diagnostic cut-off point of δDOB(13)C‰ = 19.88‰ between individuals with PD and T2D, which exhibited 100% sensitivity and 95.5% specificity. Our RGA-MS methodology for the (13)C-GBT also manifested a typical diagnostic positive and negative predictive value of 96% and 100%, respectively. The diagnostic accuracy, precision and validity of the results were also confirmed by high-resolution optical cavity enhanced integrated cavity output spectroscopy (ICOS) measurements. The δDOB(13)C‰ values measured with RGA-MS method, correlated favourably (R(2) = 0.979) with those determined by the laser based ICOS method. Moreover, we observed that the effects of endogenous CO2 production related to basal metabolic rates in individuals were statistically insignificant (p = 0.37 and 0.73) on the diagnostic accuracy. Our findings suggest that the RGA-MS is a valid and sufficiently robust method for the (13)C-GBT which may serve as an alternative non-invasive point-of-care diagnostic tool for routine clinical practices as well as for large-scale diabetes screening purposes in real-time.

  3. Extracorporeal gas exchange and spontaneous breathing for the treatment of acute respiratory distress syndrome: an alternative to mechanical ventilation?*.

    PubMed

    Langer, Thomas; Vecchi, Vittoria; Belenkiy, Slava M; Cannon, Jeremy W; Chung, Kevin K; Cancio, Leopoldo C; Gattinoni, Luciano; Batchinsky, Andriy I

    2014-03-01

    Venovenous extracorporeal gas exchange is increasingly used in awake, spontaneously breathing patients as a bridge to lung transplantation. Limited data are available on a similar use of extracorporeal gas exchange in patients with acute respiratory distress syndrome. The aim of this study was to investigate the use of extracorporeal gas exchange in awake, spontaneously breathing sheep with healthy lungs and with acute respiratory distress syndrome and describe the interactions between the native lung (healthy and diseased) and the artificial lung (extracorporeal gas exchange) in this setting. Laboratory investigation. Animal ICU of a governmental laboratory. Eleven awake, spontaneously breathing sheep on extracorporeal gas exchange. Sheep were studied before (healthy lungs) and after the induction of acute respiratory distress syndrome via IV injection of oleic acid. Six gas flow settings (1-10 L/min), resulting in different amounts of extracorporeal CO2 removal (20-100% of total CO2 production), were tested in each animal before and after the injury. Respiratory variables and gas exchange were measured for every gas flow setting. Both healthy and injured sheep reduced minute ventilation according to the amount of extracorporeal CO2 removal, up to complete apnea. However, compared with healthy sheep, sheep with acute respiratory distress syndrome presented significantly increased esophageal pressure variations (25 ± 9 vs 6 ± 3 cm H2O; p < 0.001), which could be reduced only with very high amounts of CO2 removal (> 80% of total CO2 production). Spontaneous ventilation of both healthy sheep and sheep with acute respiratory distress syndrome can be controlled via extracorporeal gas exchange. If this holds true in humans, extracorporeal gas exchange could be used in awake, spontaneously breathing patients with acute respiratory distress syndrome to support gas exchange. A deeper understanding of the pathophysiology of spontaneous breathing during acute respiratory

  4. Preschool Multiple-Breath Washout Testing. An Official American Thoracic Society Technical Statement.

    PubMed

    Robinson, Paul D; Latzin, Philipp; Ramsey, Kathryn A; Stanojevic, Sanja; Aurora, Paul; Davis, Stephanie D; Gappa, Monika; Hall, Graham L; Horsley, Alex; Jensen, Renee; Lum, Sooky; Milla, Carlos; Nielsen, Kim G; Pittman, Jessica E; Rosenfeld, Margaret; Singer, Florian; Subbarao, Padmaja; Gustafsson, Per M; Ratjen, Felix

    2018-03-01

    Obstructive airway disease is nonuniformly distributed throughout the bronchial tree, although the extent to which this occurs can vary among conditions. The multiple-breath washout (MBW) test offers important insights into pediatric lung disease, not available through spirometry or resistance measurements. The European Respiratory Society/American Thoracic Society inert gas washout consensus statement led to the emergence of validated commercial equipment for the age group 6 years and above; specific recommendations for preschool children were beyond the scope of the document. Subsequently, the focus has shifted to MBW applications within preschool subjects (aged 2-6 yr), where a "window of opportunity" exists for early diagnosis of obstructive lung disease and intervention. This preschool-specific technical standards document was developed by an international group of experts, with expertise in both custom-built and commercial MBW equipment. A comprehensive review of published evidence was performed. Recommendations were devised across areas that place specific age-related demands on MBW systems. Citing evidence where available in the literature, recommendations are made regarding procedures that should be used to achieve robust MBW results in the preschool age range. The present work also highlights the important unanswered questions that need to be addressed in future work. Consensus recommendations are outlined to direct interested groups of manufacturers, researchers, and clinicians in preschool device design, test performance, and data analysis for the MBW technique.

  5. Variables that Impact on the Results of Breath-Alcohol Tests

    ERIC Educational Resources Information Center

    Labianca, Dominick A.

    2004-01-01

    In a 2003 issue of the "Journal of Chemical Education," Kniesel and Bellamy describe a timely and pedagogically effective experiment involving breath-alcohol analysis using an FTIR (Fourier Transform Infrared Spectroscopy) spectrometer. The present article clarifies some of the information presented in the 2003 article.

  6. Evaluation of a quantitative H2S MPN test for fecal microbes analysis of water using biochemical and molecular identification.

    PubMed

    McMahan, Lanakila; Grunden, Amy M; Devine, Anthony A; Sobsey, Mark D

    2012-04-15

    The sensitivity and specificity of the H(2)S test to detect fecal bacteria in water has been variable and uncertain in previous studies, partly due to its presence-absence results. Furthermore, in groundwater samples false-positive results have been reported, with H(2)S-positive samples containing no fecal coliforms or Escherichia coli. False-negative results also have been reported in other studies, with H(2)S-negative samples found to contain E. coli. Using biochemical and molecular methods and a novel quantitative test format, this research identified the types and numbers of microbial community members present in natural water samples, including fecal indicators and pathogens as well as other bacteria. Representative water sources tested in this study included cistern rainwater, a protected lake, and wells in agricultural and forest settings. Samples from quantitative H(2)S tests of water were further cultured for fecal bacteria by spread plating onto the selective media for detection and isolation of Aeromonas spp., E. coli, Clostridium spp., H(2)S-producers, and species of Salmonella and Shigella. Isolates were then tested for H(2)S production, and identified to the genus and species level using biochemical methods. Terminal Restriction Fragment Length Polymorphisms (TRFLP) was the molecular method employed to quantitatively characterize microbial community diversity. Overall, it was shown that water samples testing positive for H(2)S bacteria also had bacteria of likely fecal origin and waters containing fecal pathogens also were positive for H(2)S bacteria. Of the microorganisms isolated from natural water, greater than 70 percent were identified using TRFLP analysis to reveal a relatively stable group of organisms whose community composition differed with water source and over time. These results further document the validity of the H(2)S test for detecting and quantifying fecal contamination of water. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. A simple test of one minute heart rate variability during deep breathing for evaluation of sympatovagal imbalance in hyperthyroidism.

    PubMed

    Shuvy, Mony; Arbelle, Jonathan E; Grosbard, Aviva; Katz, Amos

    2008-01-01

    Heart rate variability is a sensitive marker of cardiac sympathetic activity. To determine whether long-term hyperthyroidism induced by thyroxine suppressive therapy affects HRV. Nineteen patients treated with suppressive doses of thyroxin for thyroid cancer and 19 age-matched controls were enrolled. Thyroid function tests and 1 minute HRV were performed on all subjects and the results were compared between the groups. The 1 minute HRV was analyzed during deep breathing and defined as the difference in beats/minute between the shortest and the longest heart rate interval measured by eletrocardiographic recording during six cycles of deep breathing. One minute HRV during deep breathing was significantly lower among thyroxine-treated patients compared to healthy controls (25.6 +/- 10.5 vs. 34.3 +/- 12.6 beats/min, P < 0.05). There were no significant differences in mean, maximal and minimal heart rate between the groups. Thyroxine therapy administered for epithelial thyroid cancer resulted in subclinical hyperthyroidism and significantly decreased HRV due to autonomic dysfunction rather than basic elevated heart rate.

  8. Test plan 241-C-103 natural breathing characteristics evaluation using the ultra sensitive flowmeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hertelendy, N.A.

    1995-02-13

    To facilitate the reduction of worker exposure to hazardous fumes and vapors, it is imperative to characterize and measure flows out of waste tanks that breathe due to atmospheric pressure changes. These measurements will lead to a better understanding of how these tanks breathe and thus will aid in better worker exposure control at lower cost.

  9. Ventilatory muscle endurance training in quadriplegia: effects on breathing pattern.

    PubMed

    Loveridge, B; Badour, M; Dubo, H

    1989-10-01

    We examined the effects of ventilatory muscle endurance training on resting breathing pattern in 12 C6-C7 traumatic quadriplegics at least 1 year post-injury. All subjects had complete motor loss below the lesion level. Subjects were randomly assigned to a training (N = 6), or a control group (N = 6). Baseline tests included measurement of resting ventilation and breathing pattern using mercury in rubber strain gauges for 20 minutes in a seated position; maximum inspiratory mouth pressure (MIP) at FRC, and sustainable inspiratory mouth pressure for 10 minutes (SIP); lung volumes, and arterial blood gases (ABG's). The training protocol consisted of breathing through an inspiratory resistor equivalent to 85% SIP for 15 minutes twice daily, 5 days a week for 8 weeks. Both trainers and controls attended the lab every 2 weeks for reassessment of MIP and SIP and the inspiratory resistance was increased in the training group as SIP increased. At the end of 8 weeks, baseline tests were repeated. All subjects had normal ABG's. There was a significant increase in mean MIP and SIP in both the control group (30% +/- 19% and 31% +/- 18% respectively), and in the training group (42% +/- 24% and 78% +/- 49% respectively). Although the absolute values for both MIP and SIP were greater in the training group than in the control group, the differences were not significant. The alterations in resting breathing pattern were also the same in both groups. Mean frequency decreased significantly in the control group (20.2/minute to 16.9/minute) and, while insignificant, the change in frequency in the training group was the same, 19.4/minute to 16.4/minute. Mean tidal volume (Vt) increased 18.2% of baseline Vt in the control group and 17.0% baseline in the trainers, resulting in no change in minute ventilation. As MIP and SIP increased similarly in both groups, the data from the control and trainers was pooled and timing changes re-evaluated pre- and post-study. A significant decrease in

  10. Monitoring of endogenous carbon monoxide dynamics in human breath by tunable diode laser

    NASA Astrophysics Data System (ADS)

    Stepanov, Eugene V.; Daraselia, Mikhail V.; Zyrianov, Pavel V.; Shulagin, Yurii A.; Skrupskii, Vladimir A.

    1996-01-01

    High sensitive CO gas analyzer based on tunable diode laser (TDL) was used as a real time monitor of endogenous carbon monoxide in a set of breath physiology experiments. The measurements of the CO content dynamics in exhaled air with 10 ppb sensitivity were attended with detection of carbon dioxide and O2 in breath, lung ventilation parameters, heart rate and blood analysis using conventional techniques. Temporal variations of endogenous CO in human breath caused by hyperoxia, hypoxia, hyperventilation and sport loading were first studied in real time. Scattering of the CO variation time constants was observed for different tested persons. Possible reasons for this scattering related with the organisms' physiology peculiarities are discussed.

  11. Syllable-related breathing in infants in the second year of life.

    PubMed

    Parham, Douglas F; Buder, Eugene H; Oller, D Kimbrough; Boliek, Carol A

    2011-08-01

    This study explored whether breathing behaviors of infants within the 2nd year of life differ between tidal breathing and breathing supporting single unarticulated syllables and canonical/articulated syllables. Vocalizations and breathing kinematics of 9 infants between 53 and 90 weeks of age were recorded. A strict selection protocol was used to identify analyzable breath cycles. Syllables were categorized on the basis of consensus coding. Inspiratory and expiratory durations, excursions, and slopes were calculated for the 3 breath cycle types and were normalized using mean tidal breath measures. Tidal breathing cycles were significantly different from syllable-related cycles on all breathing measures. There were no significant differences between unarticulated syllable cycles and canonical syllable cycles, even after controlling for utterance duration and sound pressure level. Infants in the 2nd year of life exhibit clear differences between tidal breathing and speech-related breathing, but categorically distinct breath support for syllable types with varying articulatory demands was not evident in the present findings. Speech development introduces increasingly complex utterances, so older infants may produce detectable articulation-related adaptations of breathing kinematics. For younger infants, breath support may vary systematically among utterance types, due more to phonatory variations than to articulatory demands.

  12. Breathing pattern and head posture: changes in craniocervical angles.

    PubMed

    Sabatucci, A; Raffaeli, F; Mastrovincenzo, M; Luchetta, A; Giannone, A; Ciavarella, D

    2015-04-01

    The aim of this study was to observe the influence of oral breathing on head posture and to establish possible postural changes observing the variation of craniocervical angles NSL/OPT and NSL/CVT between oral breathing subjects and physiological breathing subjects. A cross-sectional study was conducted. The sample included 115 subject, 56 boys and 59 girls, 5-22-year-old. Among these, 80 were classified as oral breathers and 35 as physiological breathers. The diagnosis of oral breathing was carried out thanks to characteristic signs and symptoms evaluated on clinical examination, the analysis of characteristic X-ray images, ENT examination with active anterior rhinomanometric (AAR) test. The structural and postural analysis was carried out, calculating the craniofacial angles NSL/OPT and NSL/CVT. Both NSL/OPT and NSL/CVT appear to be significantly greater to those observed in physiological breathing patients. This means that patients who tend to breathe through the mouth rather than exclusively through the nose show a reduction of cervical lordosis and a proinclination of the head. Our study confirms that the oral breathing modifies head position. The significant increase of the craniocervical angles NSL/OPT and NSL/CVT in patients with this altered breathing pattern suggests an elevation of the head and a greater extension of the head compared with the cervical spine. So, to correct the breathing pattern early, either during childhood or during adolescence, can lead to a progressive normalization of craniofacial morphology and head posture.

  13. Guidelines proposal for clinical recognition of mouth breathing children.

    PubMed

    Pacheco, Maria Christina Thomé; Casagrande, Camila Ferreira; Teixeira, Lícia Pacheco; Finck, Nathalia Silveira; de Araújo, Maria Teresa Martins

    2015-01-01

    Mouth breathing (MB) is an etiological factor for sleep-disordered breathing (SDB) during childhood. The habit of breathing through the mouth may be perpetuated even after airway clearance. Both habit and obstruction may cause facial muscle imbalance and craniofacial changes. The aim of this paper is to propose and test guidelines for clinical recognition of MB and some predisposing factors for SDB in children. Semi-structured interviews were conducted with 110 orthodontists regarding their procedures for clinical evaluation of MB and their knowledge about SDB during childhood. Thereafter, based on their answers, guidelines were developed and tested in 687 children aged between 6 and 12 years old and attending elementary schools. There was no standardization for clinical recognition of MB among orthodontists. The most common procedures performed were inefficient to recognize differences between MB by habit or obstruction. The guidelines proposed herein facilitate clinical recognition of MB, help clinicians to differentiate between habit and obstruction, suggest the most appropriate treatment for each case, and avoid maintenance of mouth breathing patterns during adulthood.

  14. Evaluation of a portable evidential breath alcohol analyzer.

    PubMed

    Razatos, Gerasimos; Luthi, Ruth; Kerrigan, Sarah

    2005-10-04

    The Scientific Laboratory Division (SLD) of the Department of Health acts by mandate as the regulatory agency for the Implied Consent Program for the State of New Mexico. The Laboratory is responsible for all blood and breath alcohol testing activities for law enforcement statewide. The geographical size and the nature of the state, characterized by a highly rural population, demands portable breath alcohol testing equipment. Moreover, future expansion and success of the breath-testing program has focused on instrument portability and data management as critical issues amongst law enforcement agencies and the courts. Thus, the Implied Consent Section of the SLD evaluated the performance of the Intoxilyzer 8000, a portable instrument, against the Intoxilyzer 5000, a stationary instrument, which is currently approved for use. Instrument performance was evaluated at various ethanol concentrations, ranging from 0.04 to 0.55 g/100mL in blood or g/210 L breath. Special attention was placed on instrument performance at the per se and aggravated DWI levels of 0.08 g/100mL and 0.16 g/dL, respectively, due to their legal significance. Precision and accuracy were evaluated using in-house ethanol controls in a wet bath simulator. Coefficients of variation using the Intoxilyzer 8000 ranged from 0.30 to 1.3% (n=102), while CVs for the Intoxilyzer 5000 were 0.7-2.1% (n=102). Calibration stability was assessed in addition to the distribution of data at concentrations between 0.04 and 0.55 g/210 L. Accuracy was 100-102% for the Intoxilyzer 5000 and 99-101% using the Intoxilyzer 8000. Linear regression analysis of more than 700 comparative measurements revealed an R(2) of 1.000 (y=1.005x-0.001), where the Intoxilyzer 5000 and the Intoxilyzer 8000 were plotted on the x- and y-axis respectively. Instrument response to mouth alcohol and volatile interferences was also investigated. Potential interferences were evaluated alone or in combination with ethanol using a wet bath simulator at

  15. Dyspnea on exertion in obese women: association with an increased oxygen cost of breathing.

    PubMed

    Babb, Tony G; Ranasinghe, Kamalini G; Comeau, Laurie A; Semon, Trisha L; Schwartz, Belinda

    2008-07-15

    Although exertional dyspnea in obesity is an important and prolific clinical concern, the underlying mechanism remains unclear. To investigate whether dyspnea on exertion in otherwise healthy obese women was associated with an increase in the oxygen cost of breathing or cardiovascular deconditioning. Obese women with and without dyspnea on exertion participated in two independent experiments (n = 16 and n = 14). All participants underwent pulmonary function testing, hydrostatic weighing, ratings of perceived breathlessness during cycling at 60 W, and determination of the oxygen cost of breathing during eucapnic voluntary hyperpnea at 40 and 60 L/min. Cardiovascular exercise capacity, fat distribution, and respiratory mechanics were determined in 14 women in experiment 2. Data were analyzed between groups by independent t test, and the relationship between the variables was determined by regression analysis. In both experiments, breathlessness during 60 W cycling was markedly increased in over 37% of the obese women (P < 0.01). Age, height, weight, lung function, and %body fat were not different between the groups in either experiment. In contrast, the oxygen cost of breathing was significantly (P < 0.01) and markedly (38-70%) greater in the obese women with dyspnea on exertion. The oxygen cost of breathing was significantly (P < 0.001) correlated with the rating of perceived breathlessness obtained during the 60 W exercise in experiment 1 (r(2) = 0.57) and experiment 2 (r(2) = 0.72). Peak cardiovascular exercise capacity, fat distribution, and respiratory mechanics were not different between groups in experiment 2. Dyspnea on exertion is prevalent in otherwise healthy obese women, which seems to be strongly associated with an increased oxygen cost of breathing. Exercise capacity is not reduced in obese women with dyspnea on exertion.

  16. Breathing and Relaxation

    MedlinePlus

    ... Programs Health Information Doctors & Departments Clinical Research & Science Education & Training Home Health Insights Stress & Relaxation Breathing and Relaxation Breathing and Relaxation Make ...

  17. Determination of ethanol in breath for legal purposes using a five-filter infrared analyzer: studies on response to volatile interfering substances.

    PubMed

    Jones, Alan Wayne; Andersson, Lars

    2008-06-01

    The analysis of ethanol in exhaled breath is widely accepted and used worldwide for legal purposes to gather evidence of alcohol-impaired driving. Most evidential breath-alcohol instruments incorporate infrared (IR) spectroscopy as the analytical principle focusing on C-H or C-O stretching frequencies in ethanol molecules. The instrument approved for legal purposes in Sweden is called Evidenzer and is equipped with five infrared filters of which four are used for identification and quantification of ethanol and the fifth is a reference filter. The response of Evidenzer was tested against 21 volatile organic compounds (VOCs), and the instrument was programmed to deduct any bias caused by these VOCs if present in a sample of breath. If the amount deducted exceeds a certain threshold value, the entire test is aborted. Whenever this happens, the police request a specimen of venous blood for analysis by gas chromatography. Of a total of 24 072 drunken drivers, the evidential breath-alcohol test was aborted on 27 occasions (0.11%) because an interfering substance was present above the critical threshold. The VOCs most commonly identified in blood were acetone, isopropanol and/or methyl ethyl ketone (MEK). Elevated levels of acetone and isopropanol might arise during ketogenesis in people suffering from diabetes, or in those who eat low carbohydrate diets. High concentrations of acetone and MEK are probably caused by people drinking a technical alcohol product (T-Red), which is available in Sweden and is denatured with these agents. This study confirms that relatively few apprehended drivers in Sweden have elevated concentrations of VOCs in breath other than ethanol. Even the aborted breath tests, to a large extent, contained ethanol above the legal limit for driving.

  18. A comparison of standard inhalers for asthma with and without alcohol as the propellant on the measurement of alcohol in breath.

    PubMed

    Ignacio-García, José M; Ignacio-García, Juan M; Almenara-Barrios, José; Chocrón-Giraldez, María J; Hita-Iglesias, Carmen

    2005-01-01

    Because most bronchodilator inhalers contain propellant gases or a small amount of ethanol as a co-solvent, the potential for these products to generate false readings on a evidential breath alcohol instrument was evaluated in 69 volunteers with clinically stable asthma. All subjects underwent a breath test on an infrared breath alcohol analyzer (Alcotest 7110, Dräger, Lübeck, Germany) before the use of the asthma inhaler and 1 and 5 min after inhalation. The effects of antiasthmatic medications delivered by metered dose inhalers (MDIs) with alcohol as a vehicle, alcohol-free MDIs, and dry powder inhalers were assessed in homogeneous groups of four to five patients. All subjects were alcohol-free on the preliminary breath test. One minute after inhalation, negative readings were only observed in 25 (36.2%) of subjects. In 62.3% of patients, apparent alcohol results were considered interferences or unstable readings by the breath-test instrument. One subject showed a final positive breath alcohol level (0.07 mg/L). After the use of dry powder inhalers, valid results without interferences were obtained. However, 89.6% of patients in which bronchodilators were delivered by MDIs (with propellant gases in the aerosol) showed altered partial readings and labeled the final output as "invalid," but tests performed 5 min after the use of inhalers were valid and correct in all cases. MDIs with propellants as a vehicle may cause false positive breath alcohol readings in some patients. These effects are transient and may be prevented by a 5-10-min interval between the use of MDIs and breath alcohol testing.

  19. Deep breathing after surgery

    MedlinePlus

    ... and taking big breaths can be uncomfortable. A device called an incentive spirometer can help you take deep breaths correctly. If you do not have this device, you can still practice deep breathing on your ...

  20. Fast and Accurate Exhaled Breath Ammonia Measurement

    PubMed Central

    Solga, Steven F.; Mudalel, Matthew L.; Spacek, Lisa A.; Risby, Terence H.

    2014-01-01

    This exhaled breath ammonia method uses a fast and highly sensitive spectroscopic method known as quartz enhanced photoacoustic spectroscopy (QEPAS) that uses a quantum cascade based laser. The monitor is coupled to a sampler that measures mouth pressure and carbon dioxide. The system is temperature controlled and specifically designed to address the reactivity of this compound. The sampler provides immediate feedback to the subject and the technician on the quality of the breath effort. Together with the quick response time of the monitor, this system is capable of accurately measuring exhaled breath ammonia representative of deep lung systemic levels. Because the system is easy to use and produces real time results, it has enabled experiments to identify factors that influence measurements. For example, mouth rinse and oral pH reproducibly and significantly affect results and therefore must be controlled. Temperature and mode of breathing are other examples. As our understanding of these factors evolves, error is reduced, and clinical studies become more meaningful. This system is very reliable and individual measurements are inexpensive. The sampler is relatively inexpensive and quite portable, but the monitor is neither. This limits options for some clinical studies and provides rational for future innovations. PMID:24962141

  1. Dual gas-diffusion membrane- and mediatorless dihydrogen/air-breathing biofuel cell operating at room temperature

    NASA Astrophysics Data System (ADS)

    Xia, Hong-qi; So, Keisei; Kitazumi, Yuki; Shirai, Osamu; Nishikawa, Koji; Higuchi, Yoshiki; Kano, Kenji

    2016-12-01

    A membraneless direct electron transfer (DET)-type dihydrogen (H2)/air-breathing biofuel cell without any mediator was constructed wherein bilirubin oxidase from Myrothecium verrucaria (BOD) and membrane-bound [NiFe] hydrogenase from Desulfovibrio vulgaris Miyazaki F (MBH) were used as biocatalysts for the cathode and the anode, respectively, and Ketjen black-modified water proof carbon paper (KB/WPCC) was used as an electrode material. The KB/WPCC surface was modified with 2-aminobenzoic acid and p-phenylenediamine, respectively, to face the positively charged electron-accepting site of BOD and the negatively charged electron-donating site of MBH to the electrode surface. A gas-diffusion system was employed for the electrodes to realize high-speed substrate supply. As result, great improvement in the current density of O2 reduction with BOD and H2 reduction with MBH were realized at negatively and postively charged surfaces, respectively. Gas diffusion system also suppressed the oxidative inactivation of MBH at high electrode potentials. Finally, based on the improved bioanode and biocathode, a dual gas-diffusion membrane- and mediatorless H2/air-breathing biofuel cell was constructed. The maximum power density reached 6.1 mW cm-2 (at 0.72 V), and the open circuit voltage was 1.12 V using 1 atm of H2 gas as a fuel at room temperature and under passive and quiescent conditions.

  2. Effect of Short-Term Acclimatization to High Altitude on Sleep and Nocturnal Breathing

    PubMed Central

    Nussbaumer-Ochsner, Yvonne; Ursprung, Justyna; Siebenmann, Christoph; Maggiorini, Marco; Bloch, Konrad E.

    2012-01-01

    Study Objective: Objective physiologic data on sleep and nocturnal breathing at initial exposure and during acclimatization to high altitude are scant. We tested the hypothesis that acute exposure to high altitude induces quantitative and qualitative changes in sleep and that these changes are partially reversed with acclimatization. Design: Prospective observation. Setting: One night in a sleep laboratory at 490 meters, the first and the third night in a mountain hut at 4559 meters. Participants: Sixteen healthy mountaineers. Intervention: Altitude exposure. Measurements: Polysomnography, questionnaire evaluation of sleep and acute mountain sickness. Results: Compared to 490 m, median nocturnal oxygen saturation decreased during the 1st night at 4559 m from 96% to 67%, minute ventilation increased from 4.4 to 6.3 L/min, and the apnea-hypopnea index increased from 0.1 to 60.9/h; correspondingly, sleep efficiency decreased from 93% to 69%, and slow wave sleep from 18% to 6% (P < 0.05, all instances). During the 3rd night at 4559 m, oxygen saturation was 71%, slow wave sleep 11% (P < 0.05 vs. 1st night, both instances) and the apnea/hypopnea index was 86.5/h (P = NS vs. 1st night). Symptoms of AMS and of disturbed sleep were significantly reduced in the morning after the 3rd vs. the 1st night at 4559 m. Conclusions: In healthy mountaineers ascending rapidly to high altitude, sleep quality is initially impaired but improves with acclimatization in association with improved oxygen saturation, while periodic breathing persists. Therefore, high altitude sleep disturbances seem to be related predominantly to hypoxemia rather than to periodic breathing. Citation: Nussbaumer-Ochsner Y; Ursprung J; Siebenmann C; Maggiorini M; Bloch KE. Effect of short-term acclimatization to high altitude on sleep and nocturnal breathing. SLEEP 2012;35(3):419-423. PMID:22379248

  3. From breathing to respiration.

    PubMed

    Fitting, Jean-William

    2015-01-01

    The purpose of breathing remained an enigma for a long time. The Hippocratic school described breathing patterns but did not associate breathing with the lungs. Empedocles and Plato postulated that breathing was linked to the passage of air through pores of the skin. This was refuted by Aristotle who believed that the role of breathing was to cool the heart. In Alexandria, breakthroughs were accomplished in the anatomy and physiology of the respiratory system. Later, Galen proposed an accurate description of the respiratory muscles and the mechanics of breathing. However, his heart-lung model was hampered by the traditional view of two non-communicating vascular systems - veins and arteries. After a period of stagnation in the Middle Ages, knowledge progressed with the discovery of pulmonary circulation. The comprehension of the purpose of breathing progressed by steps thanks to Boyle and Mayow among others, and culminated with the contribution of Priestley and the discovery of oxygen by Lavoisier. Only then was breathing recognized as fulfilling the purpose of respiration, or gas exchange. A century later, a controversy emerged concerning the active or passive transfer of oxygen from alveoli to the blood. August and Marie Krogh settled the dispute, showing that passive diffusion was sufficient to meet the oxygen needs. © 2014 S. Karger AG, Basel.

  4. Spike-Timing of Orbitofrontal Neurons Is Synchronized With Breathing.

    PubMed

    Kőszeghy, Áron; Lasztóczi, Bálint; Forro, Thomas; Klausberger, Thomas

    2018-01-01

    The orbitofrontal cortex (OFC) has been implicated in a multiplicity of complex brain functions, including representations of expected outcome properties, post-decision confidence, momentary food-reward values, complex flavors and odors. As breathing rhythm has an influence on odor processing at primary olfactory areas, we tested the hypothesis that it may also influence neuronal activity in the OFC, a prefrontal area involved also in higher order processing of odors. We recorded spike timing of orbitofrontal neurons as well as local field potentials (LFPs) in awake, head-fixed mice, together with the breathing rhythm. We observed that a large majority of orbitofrontal neurons showed robust phase-coupling to breathing during immobility and running. The phase coupling of action potentials to breathing was significantly stronger in orbitofrontal neurons compared to cells in the medial prefrontal cortex. The characteristic synchronization of orbitofrontal neurons with breathing might provide a temporal framework for multi-variable processing of olfactory, gustatory and reward-value relationships.

  5. Proton detection and breathing regulation by the retrotrapezoid nucleus

    PubMed Central

    Bayliss, Douglas A.; Stornetta, Ruth L.; Ludwig, Marie‐Gabrielle; Kumar, Natasha N.; Shi, Yingtang; Burke, Peter G. R.; Kanbar, Roy; Basting, Tyler M.; Holloway, Benjamin B.; Wenker, Ian C.

    2016-01-01

    Abstract We discuss recent evidence which suggests that the principal central respiratory chemoreceptors are located within the retrotrapezoid nucleus (RTN) and that RTN neurons are directly sensitive to [H+]. RTN neurons are glutamatergic. In vitro, their activation by [H+] requires expression of a proton‐activated G protein‐coupled receptor (GPR4) and a proton‐modulated potassium channel (TASK‐2) whose transcripts are undetectable in astrocytes and the rest of the lower brainstem respiratory network. The pH response of RTN neurons is modulated by surrounding astrocytes but genetic deletion of RTN neurons or deletion of both GPR4 and TASK‐2 virtually eliminates the central respiratory chemoreflex. Thus, although this reflex is regulated by innumerable brain pathways, it seems to operate predominantly by modulating the discharge rate of RTN neurons, and the activation of RTN neurons by hypercapnia may ultimately derive from their intrinsic pH sensitivity. RTN neurons increase lung ventilation by stimulating multiple aspects of breathing simultaneously. They stimulate breathing about equally during quiet wake and non‐rapid eye movement (REM) sleep, and to a lesser degree during REM sleep. The activity of RTN neurons is regulated by inhibitory feedback and by excitatory inputs, notably from the carotid bodies. The latter input operates during normo‐ or hypercapnia but fails to activate RTN neurons under hypocapnic conditions. RTN inhibition probably limits the degree of hyperventilation produced by hypocapnic hypoxia. RTN neurons are also activated by inputs from serotonergic neurons and hypothalamic neurons. The absence of RTN neurons probably underlies the sleep apnoea and lack of chemoreflex that characterize congenital central hypoventilation syndrome. PMID:26748771

  6. [Russian oxygen generation system "Elektron-VM": hydrogen content in electrolytically produced oxygen for breathing by International Space Station crews].

    PubMed

    Proshkin, V Yu; Kurmazenko, E A

    2014-01-01

    The article presents the particulars of hydrogen content in electrolysis oxygen produced aboard the ISS Russian segment by oxygen generator "Elektron-VM" (SGK) for crew breathing. Hydrogen content was estimated as in the course of SGK operation in the ISS RS, so during the ground life tests. According to the investigation of hydrogen sources, the primary path of H2 appearance in oxygen is its diffusion through the porous diaphragm separating the electrolytic-cell cathode and anode chambers. Effectiveness of hydrogen oxidation in the SGK reheating unit was evaluated.

  7. Comparison of 72-hour fecal fat quantification and the 13C-mixed triglyceride breath test in assessing pancreatic exocrine sufficiency in children with chronic pancreatitis.

    PubMed

    Wejnarska, Karolina; Kołodziejczyk, Elwira; Ryżko, Józef; Oracz, Grzegorz

    Chronic pancreatitis (CP) in children is still a rare, although increasingly recognized entity. Over the duration of the disease several complications can be observed, two of which are major ones: endo- and exocrine insufficiency. In the medical care of children with CP it is crucial to diagnose the decreased endo- and exocrine function of the pancreas, in order to preserve patients from malnutrition and the failure to thrive. The aim of the study was to compare the usefulness of two indirect methods of assessing the pancreas exocrine function in children with CP. Ninety one patients with CP were enrolled in the study (41 boys, 50 girls, aged 2-17.8 years). Only Patients who had had both the 72-hour fecal fat quantification and the 13C-mixed triglyceride breath test (13C -MTBT) performed were selected. We compared the results of both tests for sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) in detecting exocrine pancreatic insufficiency. Out of 91 patients, 12 were diagnosed with exocrine pancreatic insufficiency (EPI). The sensitivity of the fecal fat quantification was 50%, the specificity for the test was 100%. PPV and NPV were 100% and 93%, respectively. 13C-MTBT had the sensitivity of 42% and the specificity of 99%. PPV and NPV for the breath test were of 83% and 92%, respectively. No statistically significant discrepancy between the values obtained was found. Although the 72-hour fecal fat quantification remains the gold standard in detecting EPI, both of the methods that had been investigated were shown to be comparable regarding sensitivity, specificity, PPV and NPV in assessing pancreas exocrine sufficiency in children with CP. Due to the easier execution of the breath test, both for the patient and for medical personnel, its importance may increase.

  8. Anoxia and Acidosis Tolerance of the Heart in an Air-Breathing Fish (Pangasianodon hypophthalmus).

    PubMed

    Joyce, William; Gesser, Hans; Bayley, Mark; Wang, Tobias

    2015-01-01

    Air breathing has evolved repeatedly in fishes and may protect the heart during stress. We investigated myocardial performance in the air-breathing catfish Pangasianodon hypophthalmus, a species that can withstand prolonged exposure to severe hypoxia and acidosis. Isometric ventricular preparations were exposed to anoxia, lactic acidosis, hypercapnic acidosis, and combinations of these treatments. Ventricular preparations were remarkably tolerant to anoxia, exhibiting an inotropic reduction of only 40%, which fully recovered during reoxygenation. Myocardial anoxia tolerance was unaffected by physiologically relevant elevations of bicarbonate concentration, in contrast to previous results in other fishes. Both lactic acidosis (5 mM; pH 7.10) and hypercapnic acidosis (10% CO2; pH 6.70) elicited a biphasic response, with an initial and transient decrease in force followed by overcompensation above control values. Spongy myocardial preparations were significantly more tolerant to hypercapnic acidosis than compact myocardial preparations. While ventricular preparations were tolerant to the isolated effects of anoxia and acidosis, their combination severely impaired myocardial performance and contraction kinetics. This suggests that air breathing may be a particularly important myocardial oxygen source during combined anoxia and acidosis, which may occur during exercise or environmental stress.

  9. Diagnosis of acute respiratory distress syndrome by exhaled breath analysis

    PubMed Central

    2018-01-01

    The acute respiratory distress syndrome (ARDS) is a complication of critical illness that is characterized by acute onset, protein rich, pulmonary edema. There is no treatment for ARDS, other than the reduction of additional ventilator induced lung injury. Prediction or earlier recognition of ARDS could result in preventive measurements and might decrease mortality and morbidity. Exhaled breath contains volatile organic compounds (VOCs), a collection of hundreds of small molecules linked to several physiological and pathophysiological processes. Analysis of exhaled breath through gas-chromatography and mass-spectrometry (GC-MS) has resulted in an accurate diagnosis of ARDS in several studies. Most identified markers are linked to lipid peroxidation. Octane is one of the few markers that was validated as a marker of ARDS and is pathophysiologically likely to be increased in ARDS. None of the currently studied breath analysis methods is directly applicable in clinical practice. Two steps have to be taken before any breath test can be allowed into the intensive care unit. External validation in a multi-center study is a prerequisite for any of the candidate breath markers and the breath test should outperform clinical prediction scores. Second, the technology for breath analysis should be adapted so that it is available at a decentralized lab inside the intensive care unit and can be operated by trained nurses, in order to reduce the analysis time. In conclusion, exhaled analysis might be used for the early diagnosis and prediction of ARDS in the near future but several obstacles have to be taken in the coming years. Most of the candidate markers can be linked to lipid peroxidation. Only octane has been validated in a temporal external validation cohort and is, at this moment, the top-ranking breath biomarker for ARDS. PMID:29430450

  10. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.100 Man tests 1...

  11. Study of ethane level in exhaled breath in patients with age-related macular degeneration: preliminary study.

    PubMed

    Cagini, C; Giordanelli, A; Fiore, T; Giardinieri, R; Malici, B; De Medio, G E; Pelli, M A; De Bellis, F; Capodicasa, E

    2011-01-01

    A variety of factors have been implicated in the pathogenesis of age-related macular degeneration (ARMD), and oxidative stress plays an important role in the onset and progression of the disease. Breath ethane is now considered a specific and non-invasive test for determining and monitoring the trend of lipid peroxidation and free radical-induced damage in vivo. This test provides an index of the patients' overall oxidative stress level. We evaluated the breath ethane concentration in exhaled air in patients with advanced ARMD. In this study, we enrolled 13 patients with advanced ARMD and a control group, and a breath analysis was carried out by gas chromatography. The mean ethane level in the ARMD patients was 0.82 ± 0.93 nmol/l (range: 0.01-2.7 nmol/l) and the mean ethane value in the control group was 0.12 ± 0.02 nmol/l (range: 0.08-0.16 nmol/l). The difference between the values of the 2 groups was statistically significant (p < 0.005). Receiver operating characteristic analysis showed an elevated area under the curve (0.831; 95% CI: 0.634-0.948), with a significance level of p < 0.0014 (area = 0.5). These preliminary results seem to indicate that breath ethane levels are higher in most patients with ARMD. The breath ethane test could thus be a useful method for evaluating the level of oxidative stress in patients with ARMD. To our knowledge, there are no data on this type of analysis applied to ARMD. Copyright © 2011 S. Karger AG, Basel.

  12. Role of cerebral blood flow in extreme breath holding

    PubMed Central

    Ainslie, Philip N.; Hoiland, Ryan L.; Willie, Chris K.; MacLeod, David B.; Madden, Dennis; Maslov, Petra Zubin; Drviš, Ivan; Dujić, Željko

    2016-01-01

    Abstract The role of cerebral blood flow (CBF) on a maximal breath-hold (BH) in ultra-elite divers was examined. Divers (n = 7) performed one control BH, and one BH following oral administration of the non-selective cyclooxygenase inhibitor indomethacin (1.2 mg/kg). Arterial blood gases and CBF were measured prior to (baseline), and at BH termination. Compared to control, indomethacin reduced baseline CBF and cerebral delivery of oxygen (CDO2) by about 26% (p < 0.01). Indomethacin reduced maximal BH time from 339 ± 51 to 319 ± 57 seconds (p = 0.04). In both conditions, the CDO2 remained unchanged from baseline to the termination of apnea. At BH termination, arterial oxygen tension was higher following oral administration of indomethacin compared to control (4.05 ± 0.45 vs. 3.44 ± 0.32 kPa). The absolute increase in CBF from baseline to the termination of apnea was lower with indomethacin (p = 0.01). These findings indicate that the impact of CBF on maximal BH time is likely attributable to its influence on cerebral H+ washout, and therefore central chemoreceptive drive to breathe, rather than to CDO2. PMID:28123816

  13. Role of cerebral blood flow in extreme breath holding.

    PubMed

    Bain, Anthony R; Ainslie, Philip N; Hoiland, Ryan L; Willie, Chris K; MacLeod, David B; Madden, Dennis; Maslov, Petra Zubin; Drviš, Ivan; Dujić, Željko

    2016-01-01

    The role of cerebral blood flow (CBF) on a maximal breath-hold (BH) in ultra-elite divers was examined. Divers (n = 7) performed one control BH, and one BH following oral administration of the non-selective cyclooxygenase inhibitor indomethacin (1.2 mg/kg). Arterial blood gases and CBF were measured prior to (baseline), and at BH termination. Compared to control, indomethacin reduced baseline CBF and cerebral delivery of oxygen (CDO 2 ) by about 26% (p < 0.01). Indomethacin reduced maximal BH time from 339 ± 51 to 319 ± 57 seconds (p = 0.04). In both conditions, the CDO 2 remained unchanged from baseline to the termination of apnea. At BH termination, arterial oxygen tension was higher following oral administration of indomethacin compared to control (4.05 ± 0.45 vs. 3.44 ± 0.32 kPa). The absolute increase in CBF from baseline to the termination of apnea was lower with indomethacin (p = 0.01). These findings indicate that the impact of CBF on maximal BH time is likely attributable to its influence on cerebral H + washout, and therefore central chemoreceptive drive to breathe, rather than to CDO 2 .

  14. A simple, remote, video based breathing monitor.

    PubMed

    Regev, Nir; Wulich, Dov

    2017-07-01

    Breathing monitors have become the all-important cornerstone of a wide variety of commercial and personal safety applications, ranging from elderly care to baby monitoring. Many such monitors exist in the market, some, with vital signs monitoring capabilities, but none remote. This paper presents a simple, yet efficient, real time method of extracting the subject's breathing sinus rhythm. Points of interest are detected on the subject's body, and the corresponding optical flow is estimated and tracked using the well known Lucas-Kanade algorithm on a frame by frame basis. A generalized likelihood ratio test is then utilized on each of the many interest points to detect which is moving in harmonic fashion. Finally, a spectral estimation algorithm based on Pisarenko harmonic decomposition tracks the harmonic frequency in real time, and a fusion maximum likelihood algorithm optimally estimates the breathing rate using all points considered. The results show a maximal error of 1 BPM between the true breathing rate and the algorithm's calculated rate, based on experiments on two babies and three adults.

  15. Repeatability of FDG PET/CT metrics assessed in free breathing and deep inspiration breath hold in lung cancer patients.

    PubMed

    Nygård, Lotte; Aznar, Marianne C; Fischer, Barbara M; Persson, Gitte F; Christensen, Charlotte B; Andersen, Flemming L; Josipovic, Mirjana; Langer, Seppo W; Kjær, Andreas; Vogelius, Ivan R; Bentzen, Søren M

    2018-01-01

    We measured the repeatability of FDG PET/CT uptake metrics when acquiring scans in free breathing (FB) conditions compared with deep inspiration breath hold (DIBH) for locally advanced lung cancer. Twenty patients were enrolled in this prospective study. Two FDG PET/CT scans per patient were conducted few days apart and in two breathing conditions (FB and DIBH). This resulted in four scans per patient. Up to four FDG PET avid lesions per patient were contoured. The following FDG metrics were measured in all lesions and in all four scans: Standardized uptake value (SUV) peak , SUV max , SUV mean , metabolic tumor volume (MTV) and total lesion glycolysis (TLG), based on an isocontur of 50% of SUV max . FDG PET avid volumes were delineated by a nuclear medicine physician. The gross tumor volumes (GTV) were contoured on the corresponding CT scans. Nineteen patients were available for analysis. Test-retest standard deviations of FDG uptake metrics in FB and DIBH were: SUV peak FB/DIBH: 16.2%/16.5%; SUV max : 18.2%/22.1%; SUV mean : 18.3%/22.1%; TLG: 32.4%/40.5%. DIBH compared to FB resulted in higher values with mean differences in SUV max of 12.6%, SUV peak 4.4% and SUV mean 11.9%. MTV, TLG and GTV were all significantly smaller on day 1 in DIBH compared to FB. However, the differences between metrics under FB and DIBH were in all cases smaller than 1 SD of the day to day repeatability. FDG acquisition in DIBH does not have a clinically relevant impact on the uptake metrics and does not improve the test-retest repeatability of FDG uptake metrics in lung cancer patients.

  16. Cardiorespiratory interactions during resistive load breathing.

    PubMed

    Calabrese, P; Perrault, H; Dinh, T P; Eberhard, A; Benchetrit, G

    2000-12-01

    The addition to the respiratory system of a resistive load results in breathing pattern changes and in negative intrathoracic pressure increases. The aim of this study was to use resistive load breathing as a stimulus to the cardiorespiratory interaction and to examine the extent of the changes in heart rate variability (HRV) and respiratory sinus arrhythmia (RSA) in relation to the breathing pattern changes. HRV and RSA were studied in seven healthy subjects where four resistive loads were applied in a random order during the breath and 8-min recording made in each condition. The HRV spectral power components were computed from the R-R interval sequences, and the RSA amplitude and phase were computed from the sinusoid fitting the instantaneous heart rate within each breath. Adding resistive loads resulted in 1) increasing respiratory period, 2) unchanging heart rate, and 3) increasing HRV and changing RSA characteristics. HRV and RSA characteristics are linearly correlated to the respiratory period. These modifications appear to be linked to load-induced changes in the respiratory period in each individual, because HRV and RSA characteristics are similar at a respiratory period obtained either by loading or by imposed frequency breathing. The present results are discussed with regard to the importance of the breathing cycle duration in these cardiorespiratory interactions, suggesting that these interactions may depend on the time necessary for activation and dissipation of neurotransmitters involved in RSA.

  17. Imposed Power of Breathing Associated With Use of an Impedance Threshold Device

    DTIC Science & Technology

    2007-02-01

    threshold device and a sham impedance threshold device. DESIGN: Prospective randomized blinded protocol. SETTING: University medical center. PATIENTS...for males). METHODS: The volunteers completed 2 trials of breathing through a face mask fitted with an active impedance threshold device set to open...at -7cmH 2 O pressure, or with a sham impedance threshold device, which was identical to the active device except that it did not contain an

  18. A cross-sectional study of breath acetone based on diabetic metabolic disorders.

    PubMed

    Li, Wenwen; Liu, Yong; Lu, Xiaoyong; Huang, Yanping; Liu, Yu; Cheng, Shouquan; Duan, Yixiang

    2015-02-26

    Breath acetone is a known biomarker for diabetes mellitus in breath analysis. In this work, a cross-sectional study of breath acetone based on clinical metabolic disorders of type 2 diabetes mellitus (T2DM) was carried out. Breath acetone concentrations of 113 T2DM patients and 56 apparently healthy individuals were measured at a single time point. Concentrations varied from 0.22 to 9.41 ppmv (mean 1.75 ppmv) for T2DM, which were significantly higher than those for normal controls (ranged from 0.32 to 1.96 ppmv, mean 0.72 ppmv, p = 0.008). Observations in our work revealed that breath acetone concentrations elevated to different degrees, along with the abnormality of blood glucose, glycated hemoglobin (HbA1c), triglyceride and cholesterol. Breath acetone showed obviously positive correlations with blood ketone and urine ketone. Possible metabolic relations between breath acetone and diabetic disorders were also discussed. This work aimed at giving an overall assessment of breath acetone from the perspective of clinical parameters for type 2 diabetes.

  19. Excretory nitrogen metabolism and defence against ammonia toxicity in air-breathing fishes.

    PubMed

    Chew, S F; Ip, Y K

    2014-03-01

    With the development of air-breathing capabilities, some fishes can emerge from water, make excursions onto land or even burrow into mud during droughts. Air-breathing fishes have modified gill morphology and morphometry and accessory breathing organs, which would tend to reduce branchial ammonia excretion. As ammonia is toxic, air-breathing fishes, especially amphibious ones, are equipped with various strategies to ameliorate ammonia toxicity during emersion or ammonia exposure. These strategies can be categorized into (1) enhancement of ammonia excretion and reduction of ammonia entry, (2) conversion of ammonia to a less toxic product for accumulation and subsequent excretion, (3) reduction of ammonia production and avoidance of ammonia accumulation and (4) tolerance of ammonia at cellular and tissue levels. Active ammonia excretion, operating in conjunction with lowering of ambient pH and reduction in branchial and cutaneous NH₃ permeability, is theoretically the most effective strategy to maintain low internal ammonia concentrations. NH₃ volatilization involves the alkalization of certain epithelial surfaces and requires mechanisms to prevent NH₃ back flux. Urea synthesis is an energy-intensive process and hence uncommon among air-breathing teleosts. Aestivating African lungfishes detoxify ammonia to urea and the accumulated urea is excreted following arousal. Reduction in ammonia production is achieved in some air-breathing fishes through suppression of amino acid catabolism and proteolysis, or through partial amino acid catabolism leading to alanine formation. Others can slow down ammonia accumulation through increased glutamine synthesis in the liver and muscle. Yet, some others develop high tolerance of ammonia at cellular and tissue levels, including tissues in the brain. In summary, the responses of air-breathing fishes to ameliorate ammonia toxicity are many and varied, determined by the behaviour of the species and the nature of the environment in

  20. Standardization of exhaled breath condensate (EBC) collection using a feedback regulated breathing pattern

    EPA Science Inventory

    Collection of exhaled breath condensate (EBC) fluid by cooling of expired breath is a potentially valuable approach for the detection of biomarkers associated with disease or exposure to xenobiotics. EBC is generally collected using unregulated breathing patterns, perceived to el...