Sample records for haemodialysis equipment

  1. An error taxonomy system for analysis of haemodialysis incidents.

    PubMed

    Gu, Xiuzhu; Itoh, Kenji; Suzuki, Satoshi

    2014-12-01

    This paper describes the development of a haemodialysis error taxonomy system for analysing incidents and predicting the safety status of a dialysis organisation. The error taxonomy system was developed by adapting an error taxonomy system which assumed no specific specialty to haemodialysis situations. Its application was conducted with 1,909 incident reports collected from two dialysis facilities in Japan. Over 70% of haemodialysis incidents were reported as problems or complications related to dialyser, circuit, medication and setting of dialysis condition. Approximately 70% of errors took place immediately before and after the four hours of haemodialysis therapy. Error types most frequently made in the dialysis unit were omission and qualitative errors. Failures or complications classified to staff human factors, communication, task and organisational factors were found in most dialysis incidents. Device/equipment/materials, medicine and clinical documents were most likely to be involved in errors. Haemodialysis nurses were involved in more incidents related to medicine and documents, whereas dialysis technologists made more errors with device/equipment/materials. This error taxonomy system is able to investigate incidents and adverse events occurring in the dialysis setting but is also able to estimate safety-related status of an organisation, such as reporting culture. © 2014 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  2. Vascular access for home haemodialysis.

    PubMed

    Al Shakarchi, Julien; Day, C; Inston, N

    2018-03-01

    Home haemodialysis has been advocated due to improved quality of life. However, there are very little data on the optimum vascular access for it. A retrospective cohort study was carried on all patients who initiated home haemodialysis between 2011 and 2016 at a large university hospital. Access-related hospital admissions and interventions were used as primary outcome measures. Our cohort consisted of 74 patients. On initiation of home haemodialysis, 62 individuals were using an arteriovenous fistula as vascular access, while the remaining were on a tunnelled dialysis catheter. Of the 12 patients who started on a tunnelled dialysis catheter, 5 were subsequently converted to either an arteriovenous fistula ( n = 4) or an arteriovenous graft ( n = 1). During the period of home haemodialysis use, four arteriovenous fistula failed or thrombosed with patients continuing on home haemodialysis using an arteriovenous graft ( n = 3) or a tunnelled dialysis catheter ( n = 1). To maintain uninterrupted home haemodialysis, interventional rates were 0.32 per arteriovenous fistula/arteriovenous graft access-year and 0.4 per tunnelled dialysis catheter access-year. Hospital admission rates for patients on home haemodialysis were 0.33 per patient-year. Our study has shown that home haemodialysis can be safely and independently performed at home within a closely managed home haemodialysis programme. The authors also advocate the use of arteriovenous fistulas for this cohort of patients due to both low complication and intervention rates.

  3. Haemodialysis: hospital or home?

    PubMed

    Power, Albert; Ashby, Damien

    2014-02-01

    Healthcare costs associated with the provision of dialysis therapy are escalating globally as the number of patients developing end-stage renal disease increases. In this setting, there has been heightened interest in the application and potential benefit of home haemodialysis therapies compared with the conventional approach of thrice weekly, incentre treatments. Increasingly, national healthcare systems are financially incentivising the expansion of home haemodialysis programmes with observational studies demonstrating better patient survival, superior control of circulating volume and blood pressure, greater patient satisfaction and lower running costs compared with incentre dialysis. Nonetheless, increasing the prevalence of home haemodialysis is challenged by the technological complexity of conventional dialysis systems, the need for significant adaptations to the home as well as suboptimal clinician and patient education about the feasibility and availability of this modality. In addition, enthusiasm about frequent as well as nocturnal (extended-hours) haemodialysis has been tempered by results from the recent Frequent Haemodialysis Network randomised controlled trials comparing these schedules with a conventional incentre regime. An increasing emphasis on empowering patient choice and promoting self-management of chronic illness is a powerful driver for the expansion of home haemodialysis programmes in the UK and internationally.

  4. Thrombopoietic status of patients on haemodialysis

    PubMed Central

    Bat, Taha; Bat, Betul Emine; El-Moghraby, Ahmed; Patel, Samir; Feng, Xingmin; Dunbar, Cynthia E.; Sarac, Erdal

    2015-01-01

    Thrombocytopenia is a potential dialysis-related treatment complication. Developments in bio-compatible dialyser membranes have decreased the occurrence of thrombocytopenia. We investigated whether thrombopoiesis is impaired in haemodialysis patients by measuring the thrombopoietin level and absolute immature platelet number (AIPN) in the blood of patients undergoing haemodialysis. Samples were collected from the dialysis tubing pre- and post- haemodialysis in a cohort of 45 well-characterized haemodialysis patients. Thrombopoietin levels and AIPN increased following haemodialysis, despite no change in platelet count. Observed increase in release of immature platelets from the bone marrow following haemodialysis indicates possible complement activation secondary to interaction between blood constituents and the dialysis membrane. PMID:26887628

  5. Continuing education: online monitoring of haemodialysis dose.

    PubMed

    Vartia, Aarne

    2018-01-25

    Kt/V urea reflects the efficacy of haemodialysis scaled to patient size (urea distribution volume). The guidelines recommend monthly Kt/V measurements based on blood samples. Modern haemodialysis machines are equipped with accessories monitoring the dose online at every session without extra costs, blood samples and computers. To describe the principles, devices, benefits and shortcomings of online monitoring of haemodialysis dose. A critical literature overview and discussion. UV absorbance methods measure Kt/V, ionic dialysance Kt (product of clearance and treatment time; cleared volume without scaling). Both are easy and useful methods, but comparison is difficult due to problems in scaling of the dialysis dose to the patient's size. The best dose estimation method is the one which predicts the quality of life and survival most accurately. There is some evidence on the predictive value of ionic dialysance Kt, but more documentation is required on the UV method. Online monitoring is a useful tool in everyday quality assurance, but blood samples are still required for more accurate kinetic modelling. After reading this article the reader should be able to: Understand the elements of the Kt/V equation for dialysis dose. Compare and contrast different methods of measurement of dialysis dose. Reflect on the importance of adequate dialysis dose for patient survival and life quality. © 2018 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  6. Hepatitis B virus infection in Haemodialysis Centres from Santa Catarina State, Southern Brazil. Predictive risk factors for infection and molecular epidemiology

    PubMed Central

    Carrilho, Flair J; Moraes, Cleusa R; Pinho, João RR; Mello, Isabel MVGC; Bertolini, Dennis A; Lemos, Marcílio F; Moreira, Regina C; Bassit, Leda C; Cardoso, Rita A; Ribeiro-dos-Santos, Gabriela; Da Silva, Luiz C

    2004-01-01

    Background Patients under haemodialysis are considered at high risk to acquire hepatitis B virus (HBV) infection. Since few data are reported from Brazil, our aim was to assess the frequency and risk factors for HBV infection in haemodialysis patients from 22 Dialysis Centres from Santa Catarina State, south of Brazil. Methods This study includes 813 patients, 149 haemodialysis workers and 772 healthy controls matched by sex and age. Serum samples were assayed for HBV markers and viraemia was detected by nested PCR. HBV was genotyped by partial S gene sequencing. Univariate and multivariate statistical analyses with stepwise logistic regression analysis were carried out to analyse the relationship between HBV infection and the characteristics of patients and their Dialysis Units. Results Frequency of HBV infection was 10.0%, 2.7% and 2.7% among patients, haemodialysis workers and controls, respectively. Amidst patients, the most frequent HBV genotypes were A (30.6%), D (57.1%) and F (12.2%). Univariate analysis showed association between HBV infection and total time in haemodialysis, type of dialysis equipment, hygiene and sterilization of equipment, number of times reusing the dialysis lines and filters, number of patients per care-worker and current HCV infection. The logistic regression model showed that total time in haemodialysis, number of times of reusing the dialysis lines and filters, and number of patients per worker were significantly related to HBV infection. Conclusions Frequency of HBV infection among haemodialysis patients at Santa Catarina state is very high. The most frequent HBV genotypes were A, D and F. The risk for a patient to become HBV positive increase 1.47 times each month of haemodialysis; 1.96 times if the dialysis unit reuses the lines and filters ≥ 10 times compared with haemodialysis units which reuse < 10 times; 3.42 times if the number of patients per worker is more than five. Sequence similarity among the HBV S gene from isolates

  7. Problems experienced by haemodialysis patients in Greece.

    PubMed

    Kaba, E; Bellou, P; Iordanou, P; Andrea, S; Kyritsi, E; Gerogianni, G; Zetta, S; Swigart, V

    Even though Greece has a disproportionate number of haemodialysis stations for the treatment of end-stage renal disease (ESRD), and a rapidly rising number of patients on dialysis, there has been no study of the lived experience of haemodialysis treatment in Greece. ESRD and dialysis drastically impact patients' everyday life, therefore expectations and desires play a major role in adapting to alterations and restrictions. An understanding of these culturally-influenced expectations and desires is essential for the delivery of holistic nursing care. This study aimed to explore how Greek patients receiving long-term haemodialysis perceived their problems and to describe the impact of haemodialysis on their lives. Using a grounded theory approach, 23 patients with ESRD receiving haemodialysis were purposively recruited from two hospital dialysis centres in Athens, Greece. Data were collected during 2006 by personal interviews. Given a distinctive patient experience of haemodialysis, some insight into their common concerns can facilitate provision of healthcare services that adequately meets their needs. By developing an understanding of the experience of renal illness and therapy for a group of people using dialysis, this study was intended as a contribution towards enabling healthcare professionals to provide more effective support to people who are living with this chronic condition.

  8. The Importance of Residual Kidney Function in Haemodialysis Patients.

    PubMed

    Kong, Jessica; Davies, Matthew; Mount, Peter

    2018-06-19

    In contrast to peritoneal dialysis, residual kidney function is commonly disregarded for haemodialysis patients, and not regularly monitored or taken into account in routine clinical care. This is despite evidence that higher levels of residual kidney function in haemodialysis patients associate with better outcomes including survival, total solute clearance, nutrition, inflammation, and fluid balance. This review aims to summarise the clinical effects of residual kidney function specifically in haemodialysis patients. Some level of residual kidney function is present in over 80% of patients at the time of dialysis initiation, and while this declines over time, up to 30% of patients on haemodialysis for 5 years still have a measurable level of native kidney function. There is little evidence on how best to preserve residual kidney function in haemodialysis patients, although it has been observed that intensive haemodialysis regimens in incident haemodialysis patients appear to accelerate residual kidney function decline. Residual kidney function is not commonly factored in to haemodialysis prescription and measures of adequacy, despite the fact that some guidelines such as KDOQI and European Best Practice Guidelines suggest that it is reasonable to do. This likely relates, at least in part, to perceived concerns regarding the inconvenience of timed urine collections, and to the complexity and lack of consensus regarding the methods for integrating the intermittent clearance of haemodialysis with the continuous clearance of native renal function. Further research is required into how best to maintain and maximise the benefits of residual kidney function in haemodialysis patients. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. Standardised outcomes in nephrology - Haemodialysis (SONG-HD): study protocol for establishing a core outcome set in haemodialysis.

    PubMed

    Tong, Allison; Manns, Braden; Hemmelgarn, Brenda; Wheeler, David C; Tugwell, Peter; Winkelmayer, Wolfgang C; van Biesen, Wim; Crowe, Sally; Kerr, Peter G; Polkinghorne, Kevan R; Howard, Kirsten; Pollock, Carol; Hawley, Carmel M; Johnson, David W; McDonald, Stephen P; Gallagher, Martin P; Urquhart-Secord, Rachel; Craig, Jonathan C

    2015-08-19

    Chronic kidney disease is a significant contributor to mortality and morbidity worldwide, and the number of people who require dialysis or transplantation continues to increase. People on dialysis are 15 times more likely to die than the general population. Dialysis is also costly, intrusive, and time-consuming and imposes an enormous burden on patients and their families. This escalating problem has spurred a proliferation of trials in dialysis, yet health and quality of life remain poor. The reasons for this are complex and varied but are attributable in part to problems in the design and reporting of studies, particularly outcome selection. Problems related to outcomes include use of unvalidated surrogates, outcomes of little or no relevance to patients, highly variable outcome selection limiting comparability across studies, and bias in reporting outcomes. The aim of the Standardised Outcomes in Nephrology-Haemodialysis (SONG-HD) study is to establish a core outcome set for haemodialysis trials, to improve the quality of reporting, and the relevance of trials conducted in people on haemodialysis. SONG-HD is a five-phase project that includes the following: a systematic review to identify outcomes that have been reported in haemodialysis systematic reviews and trials; nominal group technique with patients and caregivers to identify, rank, and describe reasons for their choices; qualitative stakeholder interviews with patients, caregivers, clinicians, researchers, and policy makers to elicit individual values and perspectives on outcomes for haemodialysis trials; a three-round Delphi survey with stakeholder groups to distil and generate a prioritised list of core outcomes; and a consensus workshop to establish a core outcome set for haemodialysis trials. Establishing a core outcome set to be consistently measured and reported in haemodialysis trials will improve the integrity, transparency, usability, and contribution of research relevant to patients requiring

  10. Haemodialysis dose and serum bicarbonate (chapter 7).

    PubMed

    Tomson, Charlie; Thomas, David; Rao, Raman; van Schalkwyk, Dirk; Ansell, David

    2007-08-01

    Data from 21 renal units was insufficient to allow analyses of the dose of dialysis in those units. Amongst the remainder, there is evidence of a progressive increase in the proportion of patients meeting the Renal Association audit standard for urea reduction ratio (URR). In the UK as a whole, 81% of prevalent haemodialysis patients met the standard for URR in 2005. Greater achievement of the standard in a given unit is associated with a higher median URR in that unit, although there is some evidence that some units have been able to narrow the distribution of achieved URR values. Achievement of the standard remains, as in previous years' Reports, less common amongst patients recently established on haemodialysis compared with those established on haemodialysis for longer. Correction of acidosis, as measured by serum bicarbonate concentration remains highly variable, although there is continued uncertainty about the interpretation of routine measurements of venous serum bicarbonate concentration in haemodialysis patients. Overall, approximately 64% of UK haemodialysis patients, and 50% of peritoneal dialysis patients met the Renal Association standard for serum bicarbonate in 2005.

  11. Technological intimacy in haemodialysis nursing.

    PubMed

    Bennett, Paul N

    2011-09-01

    BENNETT PN. Nursing Inquiry 2011; 18: 247-252 Technological intimacy in haemodialysis nursing Technology plays a major role in nursing care. Among the challenges for nurses is being able to maintain a patient focus while surrounded by highly complex technology. The provision of high quality nursing care in technologically complex environments is particularly challenging when nurses develop relationships with their patients over an extended period of time. In these environments the potential for intimate relationships can increase. This potential for intimacy is evident in the haemodialysis context where dialysis technology, nurses and patients interface. As nurses and patients can spend up to 20 hours per week together intimate relationships can develop. This paper identifies the challenges these dialysis nurses face and introduces the concept of technological intimacy. Technological intimacy can be defined as physical touching and self disclosure, associated with closeness and knowing, that is undertaken in the full view of others in a healthcare environment dominated by technology. In the haemodialysis context technological intimacy has been scarcely acknowledged and rarely researched. Further research will assist in guiding haemodialysis nursing practice. © 2011 Blackwell Publishing Ltd.

  12. Work environment, job satisfaction, stress and burnout among haemodialysis nurses.

    PubMed

    Hayes, Bronwyn; Douglas, Clint; Bonner, Ann

    2015-07-01

    To examine the relationships among nurse and work characteristics, job satisfaction, stress, burnout and the work environment of haemodialysis nurses. Haemodialysis nursing is characterised by frequent and intense contact with patients in a complex and intense environment. A cross-sectional online survey of 417 haemodialysis nurses that included nurse and work characteristics, the Brisbane Practice Environment Measure, Index of Work Satisfaction, Nursing Stress Scale and the Maslach Burnout Inventory. Haemodialysis nurses reported an acceptable level of job satisfaction and perceived their work environment positively, although high levels of burnout were found. Nurses who were older and had worked in haemodialysis the longest had higher satisfaction levels, experienced less stress and lower levels of burnout than younger nurses. The in-centre type of haemodialysis unit had greater levels of stress and burnout than home training units. Greater satisfaction with the work environment was strongly correlated with job satisfaction, lower job stress and emotional exhaustion. Haemodialysis nurses experienced high levels of burnout even though their work environment was favourable and they had acceptable levels of job satisfaction. Targeted strategies are required to retain and avoid burnout in younger and less experienced nurses in this highly specialised field of nursing. © 2013 John Wiley & Sons Ltd.

  13. Aggression on haemodialysis units: a mixed method study.

    PubMed

    Jones, Julia; Nijman, Henk; Ross, Jamie; Ashman, Neil; Callaghan, Patrick

    2014-09-01

    Aggression on haemodialysis units is a growing problem internationally that has received little research attention to date. Aggressive behaviour by patients or their relatives can compromise the safety and well-being of staff and other patients sharing a haemodialysis session. The objectives of the study were twofold: First, to identify the prevalance and nature of aggression on haemodialysis units; and second, to investigate factors that contribute to aggressive behaviour on haemodialysis units. A cross-sectional, sequential mixed method research design was adopted, with two research methods utilised. Incidents of aggressive behaviour were recorded over a 12-month period, using a renal version of the Staff Observation Aggression Scale. Six months after the incident data collection had commenced, semi-structured qualitative interviews were conducted with 29 multidisciplinary members of staff. Over 12 months, 74 aggressive incidents were recorded. The majority of incidents involved verbal aggression, and the perpetrators were a minority of patients, relatives and staff. Two patients were responsible for 38% of all incidents; both patients had mental health problems. Distinct temporal patterns to the aggressive behaviour were observed according to the day of the week and time of day. This study demonstrates that aggression is a significant problem on haemodialysis units, with verbal aggression most prevalent. The temporal patterns to aggression observed are related to the uniqueness of the haemodialysis setting, with a distinctly different treatment environment compared with other healthcare settings. © 2014 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  14. [Modelling of phosphorus transfers during haemodialysis].

    PubMed

    Chazot, Guillaume; Lemoine, Sandrine; Juillard, Laurent

    2017-04-01

    Chronic kidney disease causes hyperphosphatemia, which is associated with increased cardiovascular risk and mortality. In patients with end-stage renal disease, haemodialysis allows the control of hyperphosphatemia. During a 4-h haemodialysis session, between 600 and 700mg of phosphate are extracted from the plasma, whereas the latter contains only 90mg of inorganic phosphate. The precise origin of phosphates remains unknown. The modelling of phosphorus transfers allows to predict the outcome after changes in dialysis prescription (duration, frequency) with simple two-compartment models and to describe the transfers between the different body compartments with more complex models. Work using 31 P nuclear magnetic resonance spectroscopy performed in animals showed an increase in intracellular phosphate concentration and a decrease in intracellular ATP during a haemodialysis session suggesting an intracellular origin of phosphates. Copyright © 2017. Published by Elsevier Masson SAS.

  15. Intra- and extracellular magnesium levels and atheromatosis in haemodialysis patients.

    PubMed

    Tzanakis, Ioannis; Virvidakis, Kyriakos; Tsomi, Aggeliki; Mantakas, Emmanouel; Girousis, Nikolaos; Karefyllakis, Nektarios; Papadaki, Antonia; Kallivretakis, Nikolaos; Mountokalakis, Theodoros

    2004-06-01

    Traditional risk factors do not adequately explain the high prevalence of cardiovascular disease in patients with chronic renal insufficiency. Currently, there is a lot of evidence that hypomagnesaemia may play a significant role in the pathogenesis of cardiovascular diseases in general population. The aim of this study was to test the hypothesis that magnesium status in haemodialysis patients is related to the degree of atheromatosis of carotid arteries, as assessed by B-mode ultrasound. Intima-media thickness of both common carotids was assessed by B-mode ultrasound in 93 stable chronic haemodialysis patients and in 182 age- and sex-matched healthy controls. Intracellular magnesium as well as serum magnesium levels were obtained in the haemodialysis patients. Intracellular magnesium was estimated by determination of this ion in isolated peripheral lymphocytes. Haemodialysis patients had also a significantly higher mean common carotid intima-media thickness than controls (0.87+/-0.16 vs 0.76+/-0.13 mm, p < 0.001). Multivariate analysis revealed that in haemodialysis patients both serum magnesium and intracellular magnesium were negatively associated with common carotid intima-media thickness (p = 0.001 and p = 0.003 respectively). Significant associations between the age of the haemodialysis patients, the existence of diabetes mellitus as well as the serum calcium x serum phosphate product with common carotid intima-media thickness of haemodialysis patients were also observed. A strong negative association of both extracellular and intracellular magnesium with common carotid intima-media thickness exists in haemodialysis patients. The above finding suggests that magnesium may play an important protective role in the development and/or acceleration of arterial atherosclerosis in patients with chronic renal insufficiency.

  16. Haemodialysis practice in a resource-limited setting in the tropics.

    PubMed

    Okunola, Y; Ayodele, O; Akinwusi, P; Gbadegesin, B; Oluyombo, R

    2013-03-01

    To provide information on the challenges of haemodialysis in a resource limited setting in South-Western Nigeria. This is a 5 year audit of all haemodialysis sessions carried out at the renal unit of the Ladoke Akintola University Teaching Hospital (LAUTECH), Osogbo, Nigeria. A total of 225 patients were offered haemodialysis (HD) during this period with age range of 10 to 85 years (mean age of 49 years±16.25). There were 155 males and 70 females (male to female ratio of 2.2:1). Chronic kidney failure accounted for 180 (80%) of the cases while acute kidney injury (AKI) constituted 45 (20%) of the cases offered haemodialysis. The sessions of HD in both cases ranged from 1 to 27 with an average of 3 sessions. Hypotension is still the commonest intradialytic complication at our setting while diabetic nephropathy is rapidly emerging as a major cause of end stage renal disease at our setting requiring HD. As seen in other parts of the tropics sepsis, nephrotoxins and pregnancy related cases still accounted for a large percentage of AKI cases requiring haemodialysis. Only three patients were able to afford haemodialysis support for more than three months. Haemodialysis still remains a veritable option in renal replacement therapy. Problems encountered were similar to many other settings in the tropics. Intensive efforts should still be geared at preventing the risk factors for both acute kidney injury and chronic kidney disease in our environment.

  17. Laboratory signs of aspirin response in haemodialysis patients.

    PubMed

    Kilickesmez, Kadriye O; Kocas, Cuneyt; Okcun, Baris; Abaci, Okay; Kaya, Aysem; Arat, Alev; Gorcin, Bilal; Gurmen, Tevfik

    2011-09-01

    Aspirin is effective in the secondary prevention and high-risk primary prevention of cardiovascular events. However, clinical and laboratory evidence demonstrates diminished or no response to aspirin in some patients. This study was designed to assess aspirin response in haemodialysis patients. We prospectively enrolled 78 haemodialysis patients (28 female; 58.4 ± 12.6 years old) and 79 patients (29 female; 58.4 ± 10.6 years old) with normal renal function (glomerular filtration rate (GFR) >60 mL/min/1.73 m(2)). All subjects in both the haemodialysis patient group and the control group were taking aspirin (80-300 mg) for at least 30 days and were not taking other antiplatelet agents. Platelet function was assessed by arachidonic acid-induced aggregometry with a Multiplate analyser (Dynabyte Medical, Munich, Germany). Multiplate electrode aggregometry values below 300 AU were applied as a cut-off for response to aspirin. Aspirin non-response was two-fold more prevalent in haemodialysis patients (42.3%) than in patients with normal renal function (21.5%), and this difference was statistically significant (p = 0.005). The two groups were similar in terms of sex, age, tobacco use, the presence of diabetes mellitus, and platelet count. The frequency of aspirin non-response as defined in this study was higher in haemodialysis patients than in patients with normal renal function. However, larger subsets of patients are needed to confirm the present study.

  18. Management of a pregnant woman dependent on haemodialysis.

    PubMed

    Walsh, Anna-Marie

    2002-01-01

    This is a case study of a woman who became pregnant whilst receiving haemodialysis in a London teaching hospital. She courageously disregarded the doctors' advise to abort the fetus. The doctors advised her to wait until she had a kidney transplant to become pregnant again, rather than increase maternal and fetal risk on dialysis. She was due to have a live-related transplant from her father in the spring. The case study describes a practical account in detailed measure to equip nurses with the knowledge to provide specialised care to high-risk dialysis expecting mothers. The main problems in this case study were trying to manage the mother's dialysis regime, control her anaemia, ensure good nutritional levels and gain accurate daily weights.

  19. The beliefs and expectations of patients and caregivers about home haemodialysis: an interview study

    PubMed Central

    Tong, Allison; Palmer, Suetonia; Manns, Braden; Craig, Jonathan C; Ruospo, Marinella; Gargano, Letizia; Johnson, David W; Hegbrant, Jörgen; Olsson, Måns; Fishbane, Steven; Strippoli, Giovanni F M

    2013-01-01

    Objectives To explore the beliefs and expectations of patients and their caregivers about home haemodialysis in Italy where the prevalence of home haemodialysis is low. Design Semistructured, qualitative interview study with purposive sampling and thematic analysis. Setting Four dialysis centres in Italy without home haemodialysis services (Bari, Marsala, Nissoria and Taranto). Participants 22 patients receiving in-centre haemodialysis and 20 of their identified caregivers. Results We identified seven major themes that were central to patient and caregiver perceptions of home haemodialysis in regions without established services. Three positive themes were: flexibility and freedom (increased autonomy, minimised wasted time, liberation from strict dialysis schedules and gaining self-worth); comfort in familiar surroundings (family presence and support, avoiding the need for dialysis in hospital) and altruistic motivation to do home haemodialysis as an exemplar for other patients and families. Four negative themes were: disrupting sense of normality; family burden (an onerous responsibility, caregiver uncertainty and panic and visually confronting); housing constraints; healthcare by ‘professionals’ not ‘amateurs’ (relinquishing security and satisfaction with in-centre services) and isolation from peer support. Conclusions Patients without direct experience or previous education about home haemodialysis and their caregivers recognise the autonomy of home haemodialysis but are very concerned about the potential burden and personal sacrifice home haemodialysis will impose on caregivers and feel apprehensive about accepting the medical responsibilities of dialysis. To promote acceptance and uptake of home haemodialysis among patients and caregivers who have no experience of home dialysis, effective strategies are needed that provide information about home haemodialysis to patients and their caregivers, assure access to caregiver respite, provide continuous

  20. Relation between response to illness and compliance in haemodialysis patients.

    PubMed

    Saounatsou, M

    1999-01-01

    The treatment schedule of the haemodialysis patient has many restrictions and the long-term haemodialysis patient's response to illness is characterised by various emotional reactions. Compliance with their medical regimens remains a significant problem which influences the progress of health and by extension quality of life. The preconceived idea that a patient's response to illness may influence his adherence to medical regimen led to this study. The main variables examined were the relationship between the patient's response to illness and compliance and the relationship between compliance and age, education and the length of time on haemodialysis.

  1. Frequency spectrum analysis of finger photoplethysmographic waveform variability during haemodialysis.

    PubMed

    Javed, Faizan; Middleton, Paul M; Malouf, Philip; Chan, Gregory S H; Savkin, Andrey V; Lovell, Nigel H; Steel, Elizabeth; Mackie, James

    2010-09-01

    This study investigates the peripheral circulatory and autonomic response to volume withdrawal in haemodialysis based on spectral analysis of photoplethysmographic waveform variability (PPGV). Frequency spectrum analysis was performed on the baseline and pulse amplitude variabilities of the finger infrared photoplethysmographic (PPG) waveform and on heart rate variability extracted from the ECG signal collected from 18 kidney failure patients undergoing haemodialysis. Spectral powers were calculated from the low frequency (LF, 0.04-0.145 Hz) and high frequency (HF, 0.145-0.45 Hz) bands. In eight stable fluid overloaded patients (fluid removal of >2 L) not on alpha blockers, progressive reduction in relative blood volume during haemodialysis resulted in significant increase in LF and HF powers of PPG baseline and amplitude variability (P < 0.01), when expressed in mean-scaled units. The augmentation of LF powers in PPGV during haemodialysis may indicate the recovery and possibly further enhancement of peripheral sympathetic vascular modulation subsequent to volume unloading, whilst the increase in respiratory HF power in PPGV is most likely a sign of preload reduction. Spectral analysis of finger PPGV may provide valuable information on the autonomic vascular response to blood volume reduction in haemodialysis, and can be potentially utilized as a non-invasive tool for assessing peripheral circulatory control during routine dialysis procedure.

  2. The HRQoL of Chinese patients undergoing haemodialysis.

    PubMed

    Yu, Hui-Dan; Petrini, Marcia A

    2010-03-01

    With the transition from infectious disease and acute illness to chronic disease and degenerative illness as leading causes of death, health-related quality of life has become an important aspect in assessing the burden of chronic disease. The quality of life of haemodialysis patients has been studied extensively; however, very limited research using exploratory descriptive design has been carried out in this area in China. The aim of this study was to explore health-related quality of life of end-stage renal disease patients undergoing haemodialysis in China. This study used the qualitative research design approach. A semi-structured, in-depth interview was conducted with 16 haemodialysis patients in two hospitals using Colaizzi's phenomenological method to transcribe and analyse the data. The results of this study showed that dialysis patients show improvement in physical competence, but they also experienced emotional instability and psychological distress, financial burdens, inadequate disease knowledge and less social support which influenced their quality of life. To optimise the patients undergoing dialysis health-related quality of life, support of psycho-social-economical aspects should be enhanced. Health care providers should give haemodialysis patients thorough health education, individualised psychological and emotional intervention and adequate social support to optimise health-related quality of life.

  3. Empathy and stress in nurses working in haemodialysis: a qualitative study.

    PubMed

    Vioulac, Christel; Aubree, Colette; Massy, Ziad A; Untas, Aurélie

    2016-05-01

    To explore the concepts of empathy and stress in nurses working in haemodialysis units in France and their possible interactions. Nurses' work in haemodialysis is rather complex. It requires technical expertise, because of the peculiarity of the treatment, and emotional skills, to care for patients throughout a long-lasting therapy. Empathy is considered as a key in the concept of caring, which allows nurses to give appropriate answers to their patients' needs. In addition, nurses' work environment can generate stress. A qualitative descriptive design. Nurses (N = 23) working in haemodialysis units were interviewed in three different sites in 2014. The analysis of nurses' speech emphasized a predominance of the cognitive attributes of empathy: understanding, communication, adjusted response (43%), and a special feature of the relationship due to the chronicity of the care (23%). The main stressors highlighted were time management (14%), emergencies (12%) and technical nature of the task (8%). Nurses' experience in haemodialysis seemed to be a modulating factor regarding empathy and stress. The main stressors highlighted were time management (14%), emergencies (12%) and technical nature of the task (8%). Nurses' experience in haemodialysis seemed to be a modulating factor regarding empathy and stress. The results showed the special features of nurses' work in haemodialysis and the need for further studies to investigate these concepts. The influence of stress on empathy needs to be explored more precisely, especially regarding nurses' experience and its impact on patients. © 2016 John Wiley & Sons Ltd.

  4. Factors influencing adherence among Irish haemodialysis patients.

    PubMed

    Mellon, Lisa; Regan, Daniel; Curtis, Ruth

    2013-07-01

    Adherence to dietary and fluid restrictions among haemodialysis patients with end stage renal failure (ESRD) is a multi-factorial concept. This study seeks to assess the predictive value of demographic and psychological variables in non-adherence. A multi-centre cross sectional design assessed 50 haemodialysis patients on self reported adherence, attitudes towards dietary restrictions, quality of life, depression and anxiety. Adherence to fluid and dietary restrictions was measured objectively using potassium (K), phosphorus (PO4) and inter-dialytic weight gain (IDWG) parameters. 62% of patients were non-adherent with at least one aspect of the treatment regime. Regression analysis revealed age as significantly associated with adherence, in particular IDWG, with younger patients displaying poorer adherence. Younger patients may experience greater difficulty integrating complex treatment demands into their lifestyles, and non-adherence may be a consequence of the severe lifestyle limitations imposed by the haemodialysis treatment regime. Individualised interventions may be more effective than traditional methods of adherence monitoring in reducing the non-adherent behaviour. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  5. Evaluating hazardous waste generation in for-profit outpatient haemodialysis centres.

    PubMed

    García-Vicente, Sergio; Llopis-González, A; González-Steinbauer, C; Morales Suárez-Varela, M

    2016-03-01

    "Green" haemodialysis management to reduce the environmental impact of haemodialysis is growing. Dealing with hazardous waste production could heighten healthcare professionals' awareness of this problem, and improve their healthcare involvement in environmental sustainability and environmental-friendliness. A list of for-profit outpatient haemodialysis centres in the Valencian Community (E Spain) was compiled. Data on their hazardous waste production from 2008 to 2012 through the annual waste reports issued by official organisations competent in environmental issues were collected. There are 22 for-profit dialysis centres, that managed the treatment for 69.1% of all dialysis patients in the region. Data were collected from 16 centres that collectively offer 350 dialysis places (33.8% of all the places in this region). Mean annual hazardous waste production per dialysis session increased by 14% during the study period: 0.640 kg per session in 2008 vs. 0.740 kg in 2012. As hazardous waste production is high, we must examine the reasons why it is growing. Information about haemodialysis waste production and management is scarce and difficult to access. Having an evaluation of its production would motivate further research, especially as end-stage kidney disease is increasing, and whose main long-term treatment, haemodialysis, produces hazardous waste and employs substantial natural resources. Minimising its environmental impact is not mission impossible. © 2015 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  6. Randomized clinical trial on acute effects of i.v. iron sucrose during haemodialysis.

    PubMed

    Garcia-Fernandez, Nuria; Echeverria, Aitziber; Sanchez-Ibarrola, Alfonso; Páramo, José Antonio; Coma-Canella, Isabel

    2010-03-01

    Haemodialysis induces endothelial dysfunction by oxidation and inflammation. Intravenous iron administration during haemodialysis could worsen endothelial dysfunction. The aim of this study was to ascertain if iron produces endothelial dysfunction and the possible neutralizing effect of N-acetylcysteine when infused before iron. The oxidative and inflammatory effects of iron during haemodialysis were also assessed. Forty patients undergoing haemodialysis were studied in a randomized and cross-over design with and without N-acetylcysteine infused before iron sucrose (50 or 100 mg). Plasma Von Willebrand factor (vWF), soluble intercellular adhesion molecule-1 (sICAM-1) levels, malondialdehyde, total antioxidant capacity, CD11b/CD18 expression in monocytes, interleukin (IL)-8 in monocytes and plasma IL-8 were studied at baseline and during haemodialysis. Haemodialysis produced significant (P < 0.001) increase in plasma vWF, sICAM-1, malondialdehyde, IL-8 and CD11b/CD18 expression in monocytes, as well as decrease in total antioxidant capacity. Iron induced significant increase in plasma malondialdehyde and IL-8 in monocytes, but had no effect on total antioxidant capacity, CD11b/CD18 expression, plasma IL-8, vWF and sICAM-1. The addition of N-acetylcysteine to 50 mg of iron produced a significant (P = 0.040) decrease in malondialdehyde. Standard (100 mg) and low (50 mg) doses of iron during haemodialysis had no effects on endothelium. Iron only had minor effects on inflammation and produced an increase in oxidative stress, which was neutralized by N-acetylcysteine at low iron dose. Haemodialysis caused a significant increase in oxidative stress, inflammation and endothelial dysfunction markers.

  7. Baby oil therapy for uremic pruritus in haemodialysis patients.

    PubMed

    Lin, Tzu-Chen; Lai, Yu-Hung; Guo, Su-Er; Liu, Chin-Fang; Tsai, Jer-Chia; Guo, How-Ran; Hsu, Hsin-Tien

    2012-01-01

    The purpose of this study was to investigate the effectiveness of chilled/un-chilled baby oil therapy for treating uremic pruritus in haemodialysis patients. Uremic pruritus affects 50-90% of haemodialysis patients, which makes it one of the most common medical problems in this population. Pruritus can cause skin infection, desquamation, pathological skin change, sleep disorder, anxiety, depression and social dysfunction. A prospective, pretest-post-test quasi-experimental design was used. Haemodialysis patients with uremic pruritus were recruited and randomly assigned to one of three groups: experimental group 1 (chilled baby oil treatment; n = 30), experimental group 2 (un-chilled baby oil treatment; n = 31) and a control group (routine care only; n = 32). Participants in experimental group 1 and experimental group 2 were treated with chilled and un-chilled baby oil, respectively, for 15 minutes at least once daily for three weeks. The control group received no intervention other than standard care. Data collection included demographic data and itch severity. Medical records were also reviewed. The baseline characteristics of subjects in this study were as follows: 59% were male, mean age was 61·88 (SD 12·7) years, mean duration of haemodialysis was 5·31 years, mean duration of uremic pruritus was 40·58 (SD 37·8) months and mean intensity of uremic pruritus was mild. The anti-pruritic effects were significantly larger in subjects treated with either chilled or un-chilled baby oil than in those who received routine care. Anti-pruritic effects did not significantly differ between experimental group 1 and experimental group 2. The study confirmed that, for relieving pruritus in haemodialysis patients, either chilled or un-chilled baby oil is as effective as moisturising lotions and cooling soothing agents. Applying baby oil is a simple, safe, inexpensive and easily administered treatment for itchy skin in haemodialysis patients. By preventing or reducing uremic

  8. Contact allergies in haemodialysis patients: a prospective study of 75 patients.

    PubMed

    Gaudy-Marqueste, C; Jouhet, C; Castelain, M; Brunet, P; Berland, Y; Grob, J J; Richard, M A

    2009-02-01

    Haemodialysis exposes patients to many potentially sensitizing allergens. The primary objective of this study was to evaluate the prevalence of delayed hypersensitivity in a population of haemodialysis patients. Secondary objectives were to identify the possible risk factors for contact sensitization and to propose a series of skin tests adapted to haemodialysis patients. A prospective monocentric study was carried out in a nonselected population of haemodialysis patients. For each patient, medical history of atopy and allergic contact dermatitis, ongoing treatments (including topical ones), presence of eczema at the site of vascular access for haemodialysis were recorded. Allergological investigation included delayed hypersensitivity tests (European Environmental and Contact Dermatitis Research Group battery, tests GERDA, additional list and a battery of antiseptics and other dialysis-specific allergens) and latex skin prick test. Seventy-five patients (41 men, 34 women, mean age of 65 years old), with a mean 3.8 years under dialysis, were included. Nineteen patients (25%) had at least one positive skin test and 13 (17%) a positive patch test to at least one allergen relative to dialysis process including eight tests to lidocaine-prilocaine cream and three to povidone-iodine. Tests results seemed clinically relevant since nine patients had localized pruritus at the fistula site and six patients active eczema around it. Contact sensitizations are frequent in haemodialysis patients and are linked to vascular access conditioning especially the use of lidocaine-prilocaine cream. Designing a specific test battery could help to diagnose the potential allergens and subsequently to give advice to avoid contact with sensitizing agents.

  9. The impact of depression on fatigue in patients with haemodialysis: a correlational study.

    PubMed

    Bai, Yu-Ling; Lai, Liu-Yuan; Lee, Bih-O; Chang, Yong-Yuan; Chiou, Chou-Ping

    2015-07-01

    To investigate the fatigue levels and important fatigue predictors for patients undergoing haemodialysis. Fatigue is a common symptom for haemodialysis patients. With its debilitating and distressing effects, it impacts patients in terms of their quality of life while also increasing their mortality rate. A descriptive correlational study. Convenience sampling was conducted at six chosen haemodialysis centres in Southern Taiwan. Data were collected via a structured questionnaire from 193 haemodialysis patients. The scales involved in this study were socio-demographic details, the Center for Epidemiologic Studies Depression Scale, and the Fatigue Scale for haemodialysis patients. Data analysis included percentages, means, standard deviations and hierarchical multiple regression analysis. The fatigue level for haemodialysis patients was in the moderate range. Results from the hierarchical multiple regression analysis indicated that age, employment status, types of medications, physical activity and depression were significant. Of those variables, depression had the greatest impact on the patients' fatigue level, accounting for up to 30·6% of the explanatory power. The total explanatory power of the regression model was 64·2%. This study determined that for haemodialysis patients, unemployment, increased age, taking more medications or lower exercise frequencies resulted in more severe depression, which translated in turn to higher levels of fatigue. Among all these factors, depression had the greatest impact on the patients' fatigue levels. Not only is this finding beneficial to future studies on fatigue as a source of reference, it is also helpful in our understanding of important predictors relating to fatigue in the everyday lives of haemodialysis patients. It is recommended that when caring for fatigued patients, more care should be dedicated to their psychological states, and assistance should be provided in a timely way so as to reduce the amount of fatigue

  10. Psychological factors associated with successful outcomes in home haemodialysis.

    PubMed

    Nearhos, Jane; Van Eps, Carolyn; Connor, Jason

    2013-07-01

    Performing haemodialysis therapy at home has been associated with improved survival for end-stage kidney disease patients and can generally be delivered at a lower cost to the healthcare system when compared with centre and satellite unit dialysis. However, only a minority of dialysis dependent end-stage kidney disease patients successfully sustain haemodialysis at home. Current practice for determining dialysis treatment modality and location takes into account medical suitability and social situation, but infrequently formally examines the contribution of psychological factors. This study explores demographic, health, and psychological factors that may predict patients' ability to sustain home haemodialysis. One hundred and thirteen successful and unsuccessful home haemodialysis users were recruited to the study, and 55 responded to self-report measures. Demographic (age, gender, education level, carer support), health (comorbidities, diabetes, psychiatric condition) and psychological (locus of control beliefs, coping styles) information was used as predictor variables for the participants' time maintaining home therapy (Home Time). In a three-step regression, the model explained 32% of variance in Home Time. Coping styles significantly contributed 16% of the variance in Home Time after accounting for other variables. Adaptive Coping was significantly correlated with the length of time sustaining home therapy. Adaptive coping strategies are associated with improved ability to sustain home haemodialysis therapy. Evidence-based psychological approaches can help patients develop more adaptive coping strategies. More research is needed to assess whether instituting these psychological interventions will assist patients to adopt and sustain dialysis therapies which require increased patient self-management. © 2013 Metro South Hospital and Health Services, Queensland, Australia. Nephrology © 2013 Asian Pacific Society of Nephrology.

  11. Stressors and coping methods among chronic haemodialysis patients in Hong Kong.

    PubMed

    Mok, E; Tam, B

    2001-07-01

    The purpose of the study was to determine the stressors and coping methods of chronic haemodialysis patients in Hong Kong. Relationships among treatment-related stressors, coping methods and length of time on haemodialysis were explored. Fifty subjects completed the Haemodialysis Stressor Scale (HSS) and Jalowiec Coping Scale (JCS). Results revealed that limitation of fluid was the most frequently identified stressor, followed by limitation of food, itching, fatigue and cost. The most common coping methods are 'accepted the situation because very little could be done', followed by 'told oneself not to worry because everything would work out fine' and 'told oneself that the problem was really not that important.' It was found that the traditional philosophies of the Chinese--Confucianism, Buddhism, and Taoism--share an approach to the understanding and management of life stressors as different from that adopted by Western philosophies. The findings of this study can further facilitate nurse practitioners in providing support, information, and alternative solutions when assisting patients in coping with long-term haemodialysis.

  12. Effect of vitamin E-bonded dialyzer on eosinophilia in haemodialysis patients.

    PubMed

    Kojima, Kenichiro; Oda, Kuniyoshi; Homma, Hitoshi; Takahashi, Kazushi; Kanda, Yoshiko; Inokami, Taketoshi; Uchida, Shunya

    2005-09-01

    Eosinophilia in haemodialysis patients probably results from allergy to haemodialysis-related materials, including dialyzer membranes. We examined the effects of vitamin E-bonded dialyzers on eosinophil counts in haemodialysis patients. We enrolled seven patients who were on regular haemodialysis and had sustained eosinophilia. White blood cell, eosinophil, CD4- and CD8-positive lymphocyte counts, and serum interleukin-5 (IL-5) and IgE levels were determined before, 2 and 4 weeks after switching to vitamin E-bonded dialyzers. Eosinophil and CD4-positive lymphocyte counts and serum IL-5 were significantly (P = 0.003, 0.003 and 0.031, respectively) decreased after switching to vitamin E-bonded dialyzers. CD8-positive lymphocyte counts and serum IgE levels were unaltered. Crossover tests in two cases reproduced the higher eosinophilia within 4 weeks after returning to the original non-vitamin E-bonded dialyzer. Vitamin E-bonded dialyzers may ameliorate eosinophilia through a mechanism mediated by a decrease in IL-5 secretion by CD4-positive lymphocytes.

  13. Infectious-mononucleosis-like syndrome following haemodialysis for carbon tetrachloride poisoning

    PubMed Central

    Proudfoot, A. T.; Macdonald, R. H.

    1968-01-01

    A patient with renal failure after carbon tetrachloride poisoning is presented. Haemodialysis was required and renal function recovered completely. Convalescence was complicated by the development of an infectious-mononucleosis-like syndrome. The aetiology of this condition is discussed. The present case is the first to be reported after haemodialysis and transfusion of blood stored for at least 2 days. PMID:5648671

  14. Revealed access to haemodialysis facilities in northeastern Iran: Factors that matter in rural and urban areas.

    PubMed

    Kiani, Behzad; Bagheri, Nasser; Tara, Ahmad; Hoseini, Benyamin; Tabesh, Hamed; Tara, Mahmood

    2017-11-07

    Poor access to haemodialysis facilities is associated with high mortality and morbidity rates. This study investigated factors affecting revealed access to the haemodialysis facilities considering patients living in rural and urban areas without any haemodialysis facility (Group A) and those living urban areas with haemodialysis facilities (Group B). This study is based on selfreported Actual Access Time (AAT) to referred haemodialysis facilities and other information regarding travel to haemodialysis facilities from patients. All significant variables on univariate analysis were entered into a univariate general linear model in order to identify factors associated with AAT. Both spatial (driving time and distance) and non-spatial factors (sex, income level, caregivers, transportation mode, education level, ethnicity and personal vehicle ownership) influenced the revealed access identified in Group A. The non-spatial factors for Group B patients were the same as for Group A, but no spatial factor was identified in Group B. It was found that accessibility is strongly underestimated when driving time is chosen as accessibility measure to haemodialysis facilities. Analysis of revealed access determinants provides policymakers with an appropriate decision base for making appropriate decisions and finding solutions to decrease the access time for patients under haemodialysis therapy. Driving time alone is not a good proxy for measuring access to haemodialysis facilities as there are many other potential obstacles, such as women's special travel problems, poor other transportation possibilities, ethnicity disparities, low education levels, low caregiver status and low-income.

  15. [Technical advances in haemodialysis].

    PubMed

    Mercadal, Lucile; Petitclerc, Thierry

    2009-04-01

    Survival improvement of our haemodialysis patients is partly due to technologic improvement of the dialysis therapy. High permeability membranes and bicarbonate dialysate were the most relevant of past decades. What are the present technologic innovations that will provide clinical benefit? Acetate-free biofiltration, biofeedback systems, better haemodiafiltration techniques and techniques with adsorption could be part of them.

  16. Rationale and design for SHAREHD: a quality improvement collaborative to scale up Shared Haemodialysis Care for patients on centre based haemodialysis.

    PubMed

    Fotheringham, James; Barnes, Tania; Dunn, Louese; Lee, Sonia; Ariss, Steven; Young, Tracey; Walters, Stephen J; Laboi, Paul; Henwood, Andy; Gair, Rachel; Wilkie, Martin

    2017-11-24

    The study objective is to assess the effectiveness and economic impact of a structured programme to support patient involvement in centre-based haemodialysis and to understand what works for whom in what circumstances and why. It implements a program of Shared Haemodialysis Care (SHC) that aims to improve experience and outcomes for those who are treated with centre-based haemodialysis, and give more patients the confidence to dialyse independently both at centres and at home. The 24 month mixed methods cohort evaluation of 600 prevalent centre based HD patients is nested within a 30 month quality improvement program that aims to scale up SHC at 12 dialysis centres across England. SHC describes an intervention where patients who receive centre-based haemodialysis are given the opportunity to learn, engage with and undertake tasks associated with their treatment. Following a 6-month set up period, a phased implementation programme is initiated across 12 dialysis units using a randomised stepped wedge design with 6 centres participating in each of 2 steps, each lasting 6 months. The intervention utilises quality improvement methodologies involving rapid tests of change to determine the most appropriate mechanisms for implementation in the context of a learning collaborative. Running parallel with the stepped wedge intervention is a mixed methods cohort evaluation that employs patient questionnaires and interviews, and will link with routinely collected data at the end of the study period. The primary outcome measure is the number of patients performing at least 5 dialysis-related tasks collected using 3 monthly questionnaires. Secondary outcomes measures include: the number of people choosing to perform home haemodialysis or dialyse independently in-centre by the end of the study period; end-user recommendation; home dialysis establishment delay; staff impact and confidence; hospitalisation; infection and health economics. The results from this study will provide

  17. Haemodialysis, nutritional disorders and hypoglycaemia in critical care.

    PubMed

    Crespo, Jeiel Carlos Lamonica; Gomes, Vanessa Rossato; Barbosa, Ricardo Luís; Padilha, Katia Grillo; Secoli, Silvia Regina

    2017-03-09

    This study aimed to determine hypoglycemia incidence and associated factors in critically ill patients. It looked at a retrospective cohort with 106 critically ill adult patients with 48 hours of glycaemic control and 72 hours of follow up. The dependent variable, hypoglycaemia (≤70 mg/dl), was assessed with respect to independent variables: age, diet, insulin, catecholamines, haemodialysis, nursing workload and the Simplified Acute Physiology Score. Statistical analysis was performed using Student's t-test, Fisher's exact test and logistic regression at 5% significance level. Incidence of hypoglycaemia was 14.2%. Hypoglycaemia was higher in the group of patients on catecholamines (p=0.040), with higher glycaemic variability (p<0.001) and death in the intensive care unit (p=0.008). Risk factors were identified as absence of oral diet (OR 5.11; 95% CI 1.04-25.10) and haemodialysis (OR 4.28; 95% CI 1.16-15.76). Patients on haemodialysis and with no oral diet should have their glycaemic control intensified in order to prevent and/or manage hypoglycaemic episodes.

  18. HCV viraemia in anti-HCV-negative haemodialysis patients: Do we need HCV RNA detection test?

    PubMed

    Papadopoulos, Nikolaos; Griveas, Ioannis; Sveroni, Eirini; Argiana, Vasiliki; Kalliaropoulos, Antonios; Martinez-Gonzalez, Beatriz; Deutsch, Melanie

    2018-03-01

    Hepatitis C virus (HCV) infection is still common among dialysis patients, but the natural history of HCV in this group is not completely understood. The KDIGO HCV guidelines of 2009 recommend that chronic haemodialysis patients be screened for HCV antibody upon admission to the dialysis clinic and every 6 months thereafter if susceptible to HCV infection. However, previous studies have shown the presence of HCV viraemia in anti-HCV-negative haemodialysis patients as up to 22%. To evaluate the presence of HCV viraemia, using HCV RNA detection, among anti-HCV-negative haemodialysis patients from a tertiary dialysis unit in Athens. We enrolled 41 anti-HCV-negative haemodialysis patients diagnosed with third-generation enzyme immunoassay. HCV viraemia was evaluated using a sensitive (cut-off: 12 IU/mL) reverse transcriptase polymerase chain reaction (COBAS AmpliPrep/TaqMan system) for HCV RNA. None of the 41 anti-HCV-negative haemodialysis patients were shown to be viraemic. Routine HCV RNA testing appears not to be necessary in anti-HCV-negative haemodialysis patients.

  19. NURSE STAFFING AND RENAL ANAEMIA OUTCOMES IN HAEMODIALYSIS CARE.

    PubMed

    Erlingmark, Julia; Hedström, Mariann; Lindberg, Magnus

    2016-09-01

    Current trends in renal anaemia management place greater emphasis, and thus increased workload, on the role of the nurse in haemodialysis settings. However, there is little evidence that demonstrates the relationship between nurse staffing and patient outcomes. To describe nurse staffing in haemodialysis settings, its relationship with target levels of renal anaemia management and to describe target level achievement for different ways of organising anaemia management. Cross-sectional audit. Forty (out of 78) haemodialysis centres in Sweden reported quality assurance data. The numbers of bedside registered nurses, licensed nurse assistants and patients undergoing haemodialysis during a predefined morning shift; type of anaemia management and achieved target levels of anaemia management. The mean patient:registered nurse ratio was 2.4 and the mean patient:nurse assistant ratio was 12.8. There were no significant relationships between registered nurse staffing and target level achievement. On average, 45.6% of the patients had haemoglobin within the target levels at centres applying nurse-driven anaemia management, compared with 47.3% at physician-driven centres. These cross-sectional data suggest that renal anaemia outcomes are unrelated to the patient:registered nurse ratio. There is, however, room for improvement in renal anaemia management in the units included in this study, particularly the achievement of target levels of haemoglobin and transferrin saturation. © 2016 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  20. Clinical validation of the nursing diagnosis of ineffective protection in haemodialysis patients.

    PubMed

    de Sá Tinôco, Jéssica Dantas; de Paiva, Maria das Graças Mariano Nunes; de Queiroz Frazão, Cecília Maria Farias; Lucio, Kadyjina Daiane Batista; Fernandes, Maria Isabel da Conceição Dias; de Oliveira Lopes, Marcos Venicios; de Carvalho Lira, Ana Luisa Brandão

    2018-01-01

    To evaluate the clinical validity of indicators of the nursing diagnosis of "ineffective protection" in haemodialysis patients. Haemodialysis patients have reduced protection. Studies on the nursing diagnosis of "ineffective protection" are scarce in the literature. The use of indicators to diagnose "ineffective protection" could improve the care of haemodialysis patients. The clinical usefulness of the indicators requires clinical validation. This was a diagnostic accuracy study. This study assessed a sample of 200 patients undergoing haemodialysis in a reference clinic for nephrology during the first half of 2015. Operational definitions were created for each clinical indicator based on concept analysis and content validation by experts for these indicators. Diagnostic accuracy measurement was performed with latent class analysis with randomised effects. The clinical indicator of "fatigue" had high sensitivity (p = .999) and specificity (p = 1.000) for the identification of "ineffective protection." Additionally, "maladaptive response to stress" (p = .711) and "coagulation change" (p = .653) were sensitive indicators. The main indicators that showed high specificity were "fever" (p = .987), "increased number of hospitalisations" (p = .911), "weakness" (p = .937), "infected vascular access" (p = .962) and "vascular access dysfunction" (p = .722). A set of nine clinical indicators of "ineffective protection" were accurate and statistically significant for haemodialysis patients. Three clinical indicators showed sensitivity, and six indicators showed specificity. Accurate measures for nursing diagnoses can help nurses confirm or rule out the probability of the occurrence of "ineffective protection" in patients undergoing haemodialysis. © 2017 John Wiley & Sons Ltd.

  1. Evaluation of spiritual well-being in haemodialysis patients.

    PubMed

    Reig-Ferrer, Abilio; Arenas, M Dolores; Ferrer-Cascales, Rosario; Fernández-Pascual, M Dolores; Albaladejo-Blázquez, Natalia; Gil, M Teresa; de la Fuente, Vanesa

    2012-01-01

    Spirituality can be defined as a personal search for meaning and purpose in life that may or may not encompass religion. In this article we report on the development and testing of an instrument for measuring spiritual well-being within a sample of haemodialysis patients. The main instrument, a 21-item Meaning in Life Scale (MiLS), comprises four scales: Life Perspective, Purpose and Goals, Confusion and Lessened Meaning, Harmony and Peace, and Benefits of Spirituality. A total score for spiritual well-being is also produced. We also used the following variables: clinical (time on haemodialysis, modified Charlson comorbidity index), sociodemographic (age, gender), and self-assessments of health, quality of life (general and recent), personal happiness, religiosity, and belief in the afterlife. A cross-sectional study was carried out on 94 haemodialysis patients. This study demonstrates that the MiLS-Sp is a psychometrically sound measure of spiritual well-being for dialysis patients (reliability, validity) as they manage the complex demands of a chronic illness. Spiritual well-being was significantly associated with various quality of life variables, health status, personal happiness, or religiosity in patients on dialysis. There was no relationship between spirituality scores and comorbidity, HD duration, gender, or age. Spiritual well-being is relatively low in dialysis patients. Spirituality may play an important role on psychological well-being, quality of life, and self-rated health for patients on haemodialysis. Spiritual well-being in these patients is relatively low. Results suggest that assessing and addressing spiritual well-being in dialysis patients may be helpful in clinical practice.

  2. Pulmonary metastatic calcification with respiratory insufficiency in patients on maintenance haemodialysis.

    PubMed Central

    Justrabo, E; Genin, R; Rifle, G

    1979-01-01

    A uraemic patient undergoing chronic haemodialysis developed diffuse metastatic pulmonary calcification and died from acute respiratory insufficiency after renal transplantation. Thirteen similar cases previously published are reviewed, with emphasis on the clinical and anatomical features of such calcinosis. The pathogenesis of this calcification in patients on maintenance haemodialysis and some rules for its prevention are discussed. Images PMID:483215

  3. Monitoring Cole-Cole parameters during haemodialysis (HD).

    PubMed

    Al-Surkhi, Omar I; Riu, P J; Vazquez, F F; Ibeas, J

    2007-01-01

    The investigation of the hydration process during the haemodialysis treatment sessions is very important for the development of methods for predicting the unbalanced fluid shifts and hypotension crisis hence improving the quality of the haemodialysis procedure. Bioimpedance measurements can give valuable information about the tissue under measurement, therefore characterizing the tissue. In this work we propose a non-invasive method based on local multifrequency bioimpedance measurements that allow us to determine the fluid distribution and variations during haemodialysis. Clinical measurements were done using 10 HD patients during 60 HD sessions. Bioimpedance data, ultrafiltration volume, blood volume and blood heamatocrit variations were recorded continuously during the HD sessions. Bioimpedance of the local tissue was measured with a 4-elctrode impedance system using surface electrodes with sampling rate of 1meas./4min. at 6 different frequencies. The measured impedances were fitted into Cole-Cole model and the Cole-Cole parameters were continuously determined for each measurement point during the HD session. The 4 Cole-Cole parameters (R 00, R 0, Fc,alpha) and their variations were evaluated. Impedance values at infinite and zero (R 00, R 0) frequencies were extrapolated from Cole-Cole mathematical model. These values are assumed to represent the impedance of total tissue fluid and the impedance of the extracellular space respectively.

  4. Management of anaemia in haemodialysis and peritoneal dialysis patients (chapter 8).

    PubMed

    Richardson, Donald; Hodsman, Alex; van Schalkwyk, Dirk; Tomson, Charlie; Warwick, Graham

    2007-08-01

    Forty-one percent of UK patients commence RRT with an Hb < 10.0 g/dl. The mean Hb at commencement of RRT is 10.3 g/dl. Eighty-five percent of patients on dialysis in the UK have an Hb > or = 10.0 g/dl by 6 months after commencement of RRT. The median Hb on haemodialysis in the UK is 11.8 g/dl with an IQR of 10.7-12.8 g/dl. Eighty-six percent of haemodialysis patients in the UK have a Hb > or = 10.0 g/dl. The median Hb on peritoneal dialysis in the UK is 12.0 g/dl with an IQR of 11.0-12.9 g/dl. Ninety percent of peritoneal dialysis patients in the UK have an Hb > or = 10.0 g/dl. In the UK, 49% of patients on PD and 48% of patients on haemodialysis have an Hb between 10.5-12.5 g/dl. The median ferritin in UK haemodialysis patients is 413 microg/l (IQR 262-623), 95% of UK haemodialysis patients have a ferritin > or =100 microg/l. The median ferritin in UK PD patients is 256 microg/l (IQR 147-421), 86% of UK peritoneal dialysis patients have a ferritin > or = 100 microg/l. A higher proportion of HD patients than PD patients receive ESA therapy (88% vs 76%). The ESA dose is higher for HD than PD patients (9204 vs 6080 IU/week).

  5. Haemodialysis is an effective treatment in acute metabolic decompensation of maple syrup urine disease

    PubMed Central

    Atwal, P.S.; Macmurdo, C.; Grimm, P.C.

    2015-01-01

    Acute metabolic decompensation in maple syrup urine disease can occur during intercurrent illness and is a medical emergency. A handful of reports in the medical literature describe the use of peritoneal dialysis and haemodialysis as therapeutic inventions. We report the only patient from our centre to have haemodialysis performed in this setting. Combined with dietary BCAA restriction and calorific support, haemodialysis allows rapid reduction in plasma leucine concentrations considerably faster than conservative methods. PMID:26937409

  6. Haemodialysis is an effective treatment in acute metabolic decompensation of maple syrup urine disease.

    PubMed

    Atwal, P S; Macmurdo, C; Grimm, P C

    2015-09-01

    Acute metabolic decompensation in maple syrup urine disease can occur during intercurrent illness and is a medical emergency. A handful of reports in the medical literature describe the use of peritoneal dialysis and haemodialysis as therapeutic inventions. We report the only patient from our centre to have haemodialysis performed in this setting. Combined with dietary BCAA restriction and calorific support, haemodialysis allows rapid reduction in plasma leucine concentrations considerably faster than conservative methods.

  7. Haemodialysis in a rural area: a demanding form of treatment.

    PubMed

    Brammah, A; Young, G; Allan, A; Robertson, S; Norrie, J; Isles, C

    2001-09-01

    To determine distances travelled and time spent waiting for transport among hospital haemodialysis patients living in a rural area. Cross sectional survey comparing the subregional dialysis unit in south west Scotland with 12 of the other 13 Scottish Adult Renal Units. Forty three Dumfries and Galloway patients and 935 other Scottish patients receiving hospital haemodialysis in November 1999. At the time of the survey 8/43 (19%) Dumfries patients travelled in excess of 100 miles per dialysis day (15,000 miles per year) solely for the purpose of dialysis, compared to 20/935 (2%) elsewhere in Scotland (p < 0.001). Twenty seven (63%) Dumfries and 594 (64%) patients in other Scottish Units relied on hospital car, Patient Transport Service bus or ambulance for the journey home after treatment. Dumfries patients who travelled by Patient Transport Service or hospital ambulance had to wait twice as long before they left the renal unit as patients using a dedicated hospital car or private car. Haemodialysis in a rural area has every reason to be considered a demanding form of treatment. Greater promotion of home based treatment would improve the quality of life for many of these patients, while dedicated hospital cars would reduce 'car to needle time' for those who remain on hospital haemodialysis.

  8. Starting on haemodialysis: a qualitative study to explore the experience and needs of incident patients.

    PubMed

    Lai, Alden Yuanhong; Loh, Angela Ping Ping; Mooppil, Nandakumar; Krishnan, Deby Sarojiuy Pala; Griva, Konstadina

    2012-01-01

    Dialysis can be very stressful with the initial months onto treatment being highly critical in terms of both adaptation and mortality. This qualitative study aimed to explore the lived experiences of incident haemodialysis patients in Singapore. Topics related to the end-stage renal disease diagnosis and haemodialysis treatment were raised with 13 incident haemodialysis patients in the form of semi-structured interviews, and interpretative phenomenological analysis was undertaken as the framework for data analysis. Emotional distress, treatment-related concerns and social support emerged as main issues following a critical review of themes. Our study revealed that incident haemodialysis patients have emotional and informational needs, highlighting the importance of intervention programmes in particular to this patient group to promote better psychosocial adjustment to the disease and its treatment.

  9. Physical performance and protein-energy wasting in patients treated with nocturnal haemodialysis compared to conventional haemodialysis: protocol of the DiapriFIT study.

    PubMed

    Dam, Manouk; Neelemaat, Floor; Struijk-Wielinga, Trudeke; Weijs, Peter J; van Jaarsveld, Brigit C

    2017-05-01

    Poor physical performance and protein-energy wasting (PEW) are health issues of major concern in haemodialysis patients. The conventional haemodialysis (CHD) regime, three times per week 3-5 h, is subject of discussion because of high morbidity and mortality rates. When patients switch from CHD to longer dialysis sessions, i.e. nocturnal haemodialysis (NHD), improvement in protein intake and increase in body weight is seen. However, it is unclear whether physical performance and more important aspects of PEW, such as body composition, improve as well. Therefore, the aim of this study is to investigate whether physical performance improves and PEW decreases, when patients switch from CHD to NHD. A second aim is to assess the influence of NHD on the biomarkers fibroblast growth factor-23 and sclerostin which are thought to be associated with malnutrition and mortality in patients on haemodialysis. This study is a prospective multicentre cohort study with an inclusion aim of 50 patients: 25 patients in a control group (three times per week, 3-5 h CHD) and 25 patients in a nocturnal group (three times per week, 7-9 h NHD). Primary outcome is change in physical performance, measured by the Short Physical Performance Battery. Additional measurements are a 6-min walk test, handgrip strength, a physical activity questionnaire and physical activity monitoring. The secondary outcome of the study is PEW, which will be evaluated by body weight, dual-energy X-ray absorptiometry, bio-electrical impedance spectroscopy, mid-upper arm muscle circumference, subjective global assessment, visual analogue scale for appetite and dietary records. Laboratory measurements including fibroblast growth factor-23 and sclerostin, and quality of life assessed with the Kidney Disease Quality of Life-Short Form are also studied. In every patient, four repeated measurements will be performed during one year of follow-up. This study will investigate whether physical performance improves and PEW

  10. A decade review: methods to improve adherence to the treatment among haemodialysis patients.

    PubMed

    Morgan, L

    2001-01-01

    Haemodialysis patients are asked to adhere to a very difficult treatment regimen consisting of fluid and diet restrictions, many daily medications, and usually 3 or 4 hour haemodialysis sessions three times each week. Many haemodialysis patients fail to adhere to their prescribed treatment and although this regimen is difficult, it is necessary for patients to adhere for optimal health and well-being. It is important for nephrology nurses to know what interventions help patients overcome the barriers that keep them from adhering to prescribed treatment The purpose of this paper is to review the literature to examine the research that has been published on methods to improve adherence among haemodialysis patients. Behavioural approaches, education, and primary nursing are interventions that have been researched More research has been reported on the demographics of noncompliant haemodialysis patients than on effective methods that help patients improve adherence to the treatment regimen. Demographic characteristics do not consistently predict compliance for individual patients. Each patient is unique. Research supports the idea that the nephrology nurse should spend time with the patient on a regular basis in order to understand the factors that hinder the individual patient from adhering to the treatment regimen. The nurse who knows the patient well is empowered to develop individualised interventions aimed at reducing barriers that interfere with the patient's ability to adhere to treatment.

  11. Haemodialysis work environment contributors to job satisfaction and stress: a sequential mixed methods study.

    PubMed

    Hayes, Bronwyn; Bonner, Ann; Douglas, Clint

    2015-01-01

    Haemodialysis nurses form long term relationships with patients in a technologically complex work environment. Previous studies have highlighted that haemodialysis nurses face stressors related to the nature of their work and also their work environments leading to reported high levels of burnout. Using Kanters (1997) Structural Empowerment Theory as a guiding framework, the aim of this study was to explore the factors contributing to satisfaction with the work environment, job satisfaction, job stress and burnout in haemodialysis nurses. Using a sequential mixed-methods design, the first phase involved an on-line survey comprising demographic and work characteristics, Brisbane Practice Environment Measure (B-PEM), Index of Work Satisfaction (IWS), Nursing Stress Scale (NSS) and the Maslach Burnout Inventory (MBI). The second phase involved conducting eight semi-structured interviews with data thematically analyzed. From the 417 nurses surveyed the majority were female (90.9 %), aged over 41 years of age (74.3 %), and 47.4 % had worked in haemodialysis for more than 10 years. Overall the work environment was perceived positively and there was a moderate level of job satisfaction. However levels of stress and emotional exhaustion (burnout) were high. Two themes, ability to care and feeling successful as a nurse, provided clarity to the level of job satisfaction found in phase 1. While two further themes, patients as quasi-family and intense working teams, explained why working as a haemodialysis nurse was both satisfying and stressful. Nurse managers can use these results to identify issues being experienced by haemodialysis nurses working in the unit they are supervising.

  12. Haemodialysis patients' beliefs about renal failure and its treatment.

    PubMed

    Krespi, Rita; Bone, Mike; Ahmad, Rashid; Worthington, Breda; Salmon, Peter

    2004-05-01

    Patients' beliefs about illness are important because they influence adherence and adjustment, but they are often surprising and idiosyncratic. Qualitative research can identify them in ways that are not shaped by psychological theory, but quantification is necessary if clinicians are to be informed about the beliefs that are likely to be prevalent in their patients. Qualitative analysis of interviews with 16 haemodialysis (HD) patients identified beliefs about end-stage renal failure (ESRF) and its treatment that were formed into a questionnaire, completed by 156 similar patients. Patients attributed ESRF to diverse factors including lack of self-care and inadequate medical care. Patients lacked a clear belief in the mechanism of action of dietary control, and its necessity was not readily acknowledged. The common view of haemodialysis as 'cleansing' extended to the reassuring belief that it would purge the body of disallowed food or drink. Many patients regarded haemodialysis and dietary control as externally imposed challenges that dominated life. The findings identify potential targets for educational intervention to improve adherence and adjustment and predictions about effects of patients' beliefs that can be tested in future prospective studies.

  13. Predicting emotional exhaustion among haemodialysis nurses: a structural equation model using Kanter's structural empowerment theory.

    PubMed

    Hayes, Bronwyn; Douglas, Clint; Bonner, Ann

    2014-12-01

    To test an explanatory model of the relationships between the nursing work environment, job satisfaction, job stress and emotional exhaustion for haemodialysis nurses, drawing on Kanter's theory of organizational empowerment. Understanding the organizational predictors of burnout (emotional exhaustion) in haemodialysis nurses is critical for staff retention and improving nurse and patient outcomes. Previous research has demonstrated high levels of emotional exhaustion among haemodialysis nurses, yet the relationships between nurses' work environment, job satisfaction, stress and emotional exhaustion in this population are poorly understood. A cross-sectional online survey. 417 nurses working in haemodialysis units completed an online survey between October 2011-April 2012 using validated measures of the work environment, job satisfaction, job stress and emotional exhaustion. Overall, the structural equation model demonstrated adequate fit and we found partial support for the hypothesized relationships. Nurses' work environment had a direct positive effect on job satisfaction, explaining 88% of the variance. Greater job satisfaction, in turn, predicted lower job stress, explaining 82% of the variance. Job satisfaction also had an indirect effect on emotional exhaustion by mitigating job stress. However, job satisfaction did not have a direct effect on emotional exhaustion. The work environment of haemodialysis nurses is pivotal to the development of job satisfaction. Nurses' job satisfaction also predicts their level of job stress and emotional exhaustion. Our findings suggest staff retention can be improved by creating empowering work environments that promote job satisfaction among haemodialysis nurses. © 2014 John Wiley & Sons Ltd.

  14. Assessing value-based health care delivery for haemodialysis.

    PubMed

    Parra, Eduardo; Arenas, María Dolores; Alonso, Manuel; Martínez, María Fernanda; Gamen, Ángel; Aguarón, Juan; Escobar, María Teresa; Moreno-Jiménez, José María; Alvarez-Ude, Fernando

    2017-06-01

    Disparities in haemodialysis outcomes among centres have been well-documented. Besides, attempts to assess haemodialysis results have been based on non-comprehensive methodologies. This study aimed to develop a comprehensive methodology for assessing haemodialysis centres, based on the value of health care. The value of health care is defined as the patient benefit from a specific medical intervention per monetary unit invested (Value = Patient Benefit/Cost). This study assessed the value of health care and ranked different haemodialysis centres. A nephrology quality management group identified the criteria for the assessment. An expert group composed of stakeholders (patients, clinicians and managers) agreed on the weighting of each variable, considering values and preferences. Multi-criteria methodology was used to analyse the data. Four criteria and their weights were identified: evidence-based clinical performance measures = 43 points; yearly mortality = 27 points; patient satisfaction = 13 points; and health-related quality of life = 17 points (100-point scale). Evidence-based clinical performance measures included five sub-criteria, with respective weights, including: dialysis adequacy; haemoglobin concentration; mineral and bone disorders; type of vascular access; and hospitalization rate. The patient benefit was determined from co-morbidity-adjusted results and corresponding weights. The cost of each centre was calculated as the average amount expended per patient per year. The study was conducted in five centres (1-5). After adjusting for co-morbidity, value of health care was calculated, and the centres were ranked. A multi-way sensitivity analysis that considered different weights (10-60% changes) and costs (changes of 10% in direct and 30% in allocated costs) showed that the methodology was robust. The rankings: 4-5-3-2-1 and 4-3-5-2-1 were observed in 62.21% and 21.55%, respectively, of simulations, when weights were varied by 60

  15. Antioxidant therapy by oral vitamin E and vitamin E-coated dialyzer in CAPD and haemodialysis patients.

    PubMed

    Mydlík, M; Derzsiová, K; Rácz, O; Sipulová, A; Lovásová, E

    2006-01-01

    Oxidative stress, increased lipid peroxidation, and impaired function of antioxidant system may contribute to the accelerated development of atherosclerosis in chronic renal failure patients during renal replacement therapy. The aim of the study was to investigate the influence of oral vitamin E (400 mg/day) in 14 patients who underwent continuous ambulatory peritoneal dialysis (CAPD) and effects of the vitamin E-coated dialyzer in 14 haemodialysis patients on several antioxidant biochemical parameters. Six-week treatment with oral vitamin E in CAPD patients and three-month treatment using vitamin E-coated dialyzer in haemodialysis patients led to the significant decrease of plasma malondialdehyde, to the increase of plasma vitamin E and to the increase of erythrocyte vitamin E in haemodialysis patients. No significant changes of erythrocyte antioxidant enzyme--superoxide dismutase, glutathione peroxidase and catalase were found during the both types of antioxidant therapy. At the end of the third month of haemodialysis study the significant increase of erythrocyte glutathione in haemodialysis patients was found, but that value was significantly lower as normal range. Six-week interruption of the administration of oral vitamin E in CAPD patients led to the significant decrease of erythrocyte superoxide dismutase and plasma vitamin E. Ten-week interruption of the use of vitamin E-coated dialyzer led to the significant increase of plasma malondialdehyde and to the decrease of plasma and erythrocyte vitamin E in haemodialysis patients, near to the values at the beginning of the study. Our study confirmed the beneficial effect of oral administration of vitamin E and the use of vitamin E-coated dialyzer against oxidative stress in CAPD and haemodialysis patients.

  16. Dietary and fluid restriction perceptions of patients undergoing haemodialysis: an exploratory study.

    PubMed

    Hong, Leting Isabella; Wang, Wenru; Chan, Ee Yuee; Mohamed, Fatimah; Chen, Hui-Chen

    2017-11-01

    To explore the perspectives of patients undergoing haemodialysis in Singapore on an imposed dietary and fluid restriction regime. Adherence to prescribed dietary and fluid restriction constructs the fundamental basis of self-care with improved morbidity and mortality. However, most patients have struggled to adhere in this aspect. Existing studies have presented limited understanding on the facilitators and barriers of dietary and fluid adherence among haemodialysis patients. An exploratory qualitative study. A purposive sample of 14 patients undergoing haemodialysis was recruited from a renal unit of a tertiary hospital in Singapore. Data were collected through face-to-face individual interviews and subsequently analysed by thematic analysis. Four themes emerged: (1) Pessimism, (2) Existing struggles, (3) Perceived quality of support, and (4) Immensity of self-discipline. The imposed dietary and fluid restriction is a constant struggle and a cause of suffering among haemodialysis patients in Singapore. Nonetheless, they are generally submissive to their fluid restrictions for the sake of survival or to meet the expectations of their loved ones. The imposed dietary restrictions are generally neglected. The findings from this study can provide useful information in reviewing existing educational strategies, policies and nursing care. This is especially important because most patients exhibit high reliance on healthcare professionals. © 2017 John Wiley & Sons Ltd.

  17. [Dialin: infection surveillance network for haemodialysis patients. First results].

    PubMed

    Ayzac, Louis; Béruard, Michel; Girard, Raphaële; Hannoun, Jacques; Kuentz, François; Marc, Jean-Michel; Moreau-Gaudry, Xavier; Roche, Catherine; Tressières, Benoît; Uzan, Marc

    2009-02-01

    To show results of the first year of an infection surveillance network for haemodialysis patients (Dialin). In order to improve the security and quality of care, six haemodialysis centers have organized an infection watching network. The purpose of the network is to compare of the watching results between centers. This comparison includes vascular access infection (VAI), bacteraemia and C viral hepatitis. The heterogeneous pattern has been also taken into account. SURVEY TYPE: Multicenter prospective permanent survey. Six hundred and sixty-four haemodialyzed chronic patients, followed during one year (2005), in six voluntary haemodialysis centers. This survey has based on 71,688 treatment sessions corresponding to 6257.5 months of haemodialysis (HM). As with the heterogeneity among centers, the acquired infection standardized ratios (observed/expected) (AISR) and 95% confidence interval are computed with Cox model which includes confounding factors found in literature or in the preliminary stage of the survey. VAI crude rate was 0.47 per 100HM, 0.10 per 1000 native fistulae utilisation days, 0.45 per 1000 days of prosthetic graft utilisation and 0.44 per 1000 days of catheter utilisation. Bacteraemia crude incidence rate was 0.69 per 100HM, 0.02 per 1000 days of native fistulae utilisation, 0.00 per 1000 days of prosthetic graft utilisation and 0.39 per 1000 days of catheter utilisation. No new case of C viral hepatitis was found. Prevalence rate at the beginning of the survey was 5.3% (35 over 664). Two centers had a significantly high AISR for VAI and two centers had a significantly low AISR for VAI. One center had a significantly high AISR for bacteraemia and one center had a significantly low AISR for bacteraemia. The first year of Dialin running demonstrates the importance of standardised surveillance method in VAI and bacteraemia surveillance but not for viral hepatitis.

  18. Impact of high-flux haemodialysis on the probability of target attainment for oral amoxicillin/clavulanic acid combination therapy.

    PubMed

    Hui, Katrina; Patel, Kashyap; Kong, David C M; Kirkpatrick, Carl M J

    2017-07-01

    Clearance of small molecules such as amoxicillin and clavulanic acid is expected to increase during high-flux haemodialysis, which may result in lower concentrations and thus reduced efficacy. To date, clearance of amoxicillin/clavulanic acid (AMC) during high-flux haemodialysis remains largely unexplored. Using published pharmacokinetic parameters, a two-compartment model with first-order input was simulated to investigate the impact of high-flux haemodialysis on the probability of target attainment (PTA) of orally administered AMC combination therapy. The following pharmacokinetic/pharmacodynamic targets were used to calculate the PTA. For amoxicillin, the time that the free concentration remains above the minimum inhibitory concentration (MIC) of ≥50% of the dosing period (≥50%ƒT >MIC ) was used. For clavulanic acid, the time that the free concentration was >0.1 mg/L of ≥45% of the dosing period (≥45%ƒT >0.1 mg/L ) was used. Dialysis clearance reported in low-flux haemodialysis for both compounds was doubled to represent the likely clearance during high-flux haemodialysis. Monte Carlo simulations were performed to produce concentration-time profiles over 10 days in 1000 virtual patients. Seven different regimens commonly seen in clinical practice were explored. When AMC was dosed twice daily, the PTA was mostly ≥90% for both compounds regardless of when haemodialysis commenced. When administered once daily, the PTA was 20-30% for clavulanic acid and ≥90% for amoxicillin. The simulations suggest that once-daily orally administered AMC in patients receiving high-flux haemodialysis may result in insufficient concentrations of clavulanic acid to effectively treat infections, especially on days when haemodialysis occurs. Copyright © 2017 Elsevier B.V. and International Society of Chemotherapy. All rights reserved.

  19. The work environment of haemodialysis nurses and its impact on patients' outcomes.

    PubMed

    Prezerakos, Panagiotis; Galanis, Peter; Moisoglou, Ioannis

    2015-04-01

    The aims of this study were to assess haemodialysis nurses' work environment and investigate the correlation between work environment and patients' outcomes. A cross-sectional study was conducted at the 11 public hospital-based haemodialysis units of the 5th Regional Health Authority of Greece. The Practice Environment Scale of the Nursing Work Index (PES-NWI) was used to assess work environment. Nurses were asked to report the frequency of a series adverse events and errors. Study population consisted of 133 nurses (response rate 89.3%). The overall PES-NWI scored just < 2.5 (Mean = 2.48, standard deviation = 0.34) indicating a non-favourable haemodialysis workplace. Nurse-physician Relations, nurse manager ability and nursing foundations for quality of care were the most favourable aspects of work environment. Multivariate logistic regression analysis identified that hypotension (odds ratio (OR) = 0.3, 95% confidence interval (CI) = 0.1-0.9, P = 0.03), venous needle disconnection (OR = 0.14, 95% CI = 0.03-0.65, P = 0.012) and patient fall (OR = 0.02, 95% CI = 0.001-0.51, P = 0.018) were associated with a non-favourable work environment. Findings have important implications for improvement of haemodialysis work environment and enhancement of patients' safety. © 2013 Wiley Publishing Asia Pty Ltd.

  20. 10 years' experience with regular haemodialysis and renal transplantation.

    PubMed Central

    Chantler, C; Carter, J E; Bewick, M; Counahan, R; Cameron, J S; Ogg, C S; Williams, D G; Winder, E

    1980-01-01

    75 children aged under 15 years have entered the regular haemodialysis/renal transplant programme at Guy's Hospital in the 10 years since its inception; 13 children have subsequently died. A combination of hospital and home haemodialysis and renal transplantation was used. 64 children received 80 renal allografts; 37 1st grafts were from live, related donors and 27 were from cadaver donors. The 5-year acturial patient survival for the whole group and for those who had transplants was 76%. Live donor graft survival was 65% at 3 years, and 55% at 5 years; 1st cadaver graft survival was 42% at 3 years. Results obtained during the last 6 years of the 10-year period showed an improvement with a live related donor graft survival rate of 71%, and a 1st cadaver graft survival rate of 47% at 3 years. Particular experience was gained with home haemodialysis and live, related donor transplantation. Despite growth, and psychosocial and rehabilitation problems, the overall results were encouraging, particularly for the 46 children who had successful transplants. These children grew better, had fewer psychosocial difficulties, and were rehabilitated more successfully into normal life than those on long-term dialysis. We conclude that dialysis and transplantation should be offered to all suitable children with terminal renal failure. PMID:7002057

  1. Nonadherence to Medication Therapy in Haemodialysis Patients: A Systematic Review.

    PubMed

    Ghimire, Saurav; Castelino, Ronald L; Lioufas, Nicole M; Peterson, Gregory M; Zaidi, Syed Tabish R

    2015-01-01

    End-stage kidney disease (ESKD) patients are often prescribed multiple medications. Together with a demanding weekly schedule of dialysis sessions, increased number of medicines and associated regimen complexity pre-dispose them at high risk of medication nonadherence. This review summarizes existing literature on nonadherence and identifies factors associated with nonadherence to medication therapy in patients undergoing haemodialysis. A comprehensive search of PubMed, Embase, CINAHL, PsycInfo, and Cochrane Database of Systematic Reviews covering the period from 1970 through November 2014 was performed following a predefined inclusion and exclusion criteria. Reference lists from relevant materials were reviewed. Data on study characteristics, measures of nonadherence, prevalence rates and factors associated with nonadherence were collected. The Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines was followed in conducting this systematic review. Of 920 relevant publications, 44 were included. The prevalence of medication nonadherence varied from 12.5% to 98.6%, with widespread heterogeneity in measures and definitions employed. Most common patient-related factors significantly associated with nonadherence were younger age, non-Caucasian ethnicity, illness interfering family life, being a smoker, and living single and being divorced or widowed. Similarly, disease-related factors include longevity of haemodialysis, recurrent hospitalization, depressive symptoms and having concomitant illness like diabetes and hypertension. Medication-related factors such as daily tablet count, total pill burden, number of phosphate binders prescribed and complexity of medication regimen were also associated with poor adherence. A number of patient-, disease-, and medication-related factors are associated with medication nonadherence in haemodialysis patients. Clinicians should be aware of such factors so that adherence to medications can be

  2. The effect of reflexology applied on haemodialysis patients with fatigue, pain and cramps.

    PubMed

    Ozdemir, Gülistan; Ovayolu, Nimet; Ovayolu, Ozlem

    2013-06-01

    The research was conducted to evaluate the effect of foot reflexology on fatigue, pain and cramps in haemodialysis patients. The sample consisted of 80 patients in total, 40 intervention and 40 control patients, receiving treatment in the haemodialysis units of two institutions. Data were collected by using a questionnaire, Piper Fatigue Scale and visual analogue scale for measuring the severity of cramp and pain. The intervention group received reflexology treatment for 1 week in three sessions following haemodialysis, each session lasting approximately 30 min. Parametric and non-parametric tests were used in data analysis. It was determined that reflexology reduced the fatigue subscale scores and total scale scores as well as pain and cramp mean scores in the intervention group. The research results revealed that the severity of fatigue, pain and cramp decreased in patients receiving reflexology. © 2013 Wiley Publishing Asia Pty Ltd.

  3. Design and validation of a model to predict early mortality in haemodialysis patients.

    PubMed

    Mauri, Joan M; Clèries, Montse; Vela, Emili

    2008-05-01

    Mortality and morbidity rates are higher in patients receiving haemodialysis therapy than in the general population. Detection of risk factors related to early death in these patients could be of aid for clinical and administrative decision making. Objectives. The aims of this study were (1) to identify risk factors (comorbidity and variables specific to haemodialysis) associated with death in the first year following the start of haemodialysis and (2) to design and validate a prognostic model to quantify the probability of death for each patient. An analysis was carried out on all patients starting haemodialysis treatment in Catalonia during the period 1997-2003 (n = 5738). The data source was the Renal Registry of Catalonia, a mandatory population registry. Patients were randomly divided into two samples: 60% (n = 3455) of the total were used to develop the prognostic model and the remaining 40% (n = 2283) to validate the model. Logistic regression analysis was used to construct the model. One-year mortality in the total study population was 16.5%. The predictive model included the following variables: age, sex, primary renal disease, grade of functional autonomy, chronic obstructive pulmonary disease, malignant processes, chronic liver disease, cardiovascular disease, initial vascular access and malnutrition. The analyses showed adequate calibration for both the sample to develop the model and the validation sample (Hosmer-Lemeshow statistic 0.97 and P = 0.49, respectively) as well as adequate discrimination (ROC curve 0.78 in both cases). Risk factors implicated in mortality at one year following the start of haemodialysis have been determined and a prognostic model designed. The validated, easy-to-apply model quantifies individual patient risk attributable to various factors, some of them amenable to correction by directed interventions.

  4. Factors influencing the quality of life of haemodialysis patients according to symptom cluster.

    PubMed

    Shim, Hye Yeung; Cho, Mi-Kyoung

    2018-05-01

    To identify the characteristics in each symptom cluster and factors influencing the quality of life of haemodialysis patients in Korea according to cluster. Despite developments in renal replacement therapy, haemodialysis still restricts the activities of daily living due to pain and impairs physical functioning induced by the disease and its complications. Descriptive survey. Two hundred and thirty dialysis patients aged >18 years. They completed self-administered questionnaires of Dialysis Symptom Index and Kidney Disease Quality of Life instrument-Short Form 1.3. To determine the optimal number of clusters, the collected data were analysed using polytomous variable latent class analysis in R software (poLCA) to estimate the latent class models and the latent class regression models for polytomous outcome variables. Differences in characteristics, symptoms and QOL according to the symptom cluster of haemodialysis patients were analysed using the independent t test and chi-square test. The factors influencing the QOL according to symptom cluster were identified using hierarchical multiple regression analysis. Physical and emotional symptoms were significantly more severe, and the QOL was significantly worse in Cluster 1 than in Cluster 2. The factors influencing the QOL were spouse, job, insurance type and physical and emotional symptoms in Cluster 1, with these variables having an explanatory power of 60.9%. Physical and emotional symptoms were the only influencing factors in Cluster 2, and they had an explanatory power of 37.4%. Mitigating the symptoms experienced by haemodialysis patients and improving their QOL require educational and therapeutic symptom management interventions that are tailored according to the characteristics and symptoms in each cluster. The findings of this study are expected to lead to practical guidelines for addressing the symptoms experienced by haemodialysis patients, and they provide basic information for developing nursing

  5. Development of certified environmental management in hospital and outpatient haemodialysis units.

    PubMed

    García Vicente, Sergio; Morales Suárez-Varela, María; Martí Monrós, Anna; Llopis González, Agustín

    2015-01-01

    The environmental impact of haemodialysis is very high. Institutional activity in this sense is important, even in the production of references. Voluntary environmental management systems (EMS), environmental management and auditing systems (EMAS) and the International Organization for Standardization standards (ISO 14001) are important tools for environmental protection, together with legislation, taxation and tax benefits. To determine the degree of implementation of EMS in hospital units and outpatient haemodialysis in the Spanish National Health System to provide a group of reference centres in environmental management in this healthcare activity. Development of a list by autonomous communities showing hospital and outpatient dialysis units using an EMAS and/or ISO 14001 in 2012-2013. The sources of information were the Spanish National Catalogue of Hospitals, Spanish Registry of Healthcare Certification and Accreditation, European and regional EMAS records, world ISO registrations, dialysis centre lists from scientific societies and patients, responses from accredited entities in Spain for environmental certification and the institutional website of each haemodialysis centre identified. Of the 210 hospitals with a dialysis unit, 53 (25%) have the ISO 14001 and 15 of these also have an EMAS). This constitutes 30% of all hospital dialysis chairs in Spain: 1,291 (of 4,298). Only 11 outpatient clinics are recorded, all with the ISO 14001. There is no official documentation of the implementation of EMS in dialysis units. Making this list provides an approach to the situation, with special reference to haemodialysis because of its significant environmental impact. Copyright © 2015 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  6. Effect of a self-efficacy promotion training programme on the body weight changes in patients undergoing haemodialysis.

    PubMed

    Aliasgharpour, Mansooreh; Shomali, Maryam; Moghaddam, Masoumeh Zakeri; Faghihzadeh, Sograt

    2012-09-01

    Haemodialysis is the most common form of medical management of patients affected by end-stage renal disease (ESRD). For haemodialysis to be successful, strict fluid and weight control is recommended. Education, in terms of self-care activities, is an important intervention for improving patients' outcomes. A self-efficacy promotion training programme can be an effective strategy to bring about behavioural change. The aim of this study was to investigate the effect of a self-efficacy promotion training programme on the body weight changes in patients undergoing haemodialysis. In this single-blind quasi-experimental study, we recruited a convenience sample of 63 patients undergoing haemodialy-sis from two teaching hospitals and allocated them randomly to the experimental or control group. Patients in the experimental group received a six-session self-efficacy promotion training programme while the control group received the routine care of the institute. Mean body weight gain and self-efficacy were measured before, immediately and two months after the study. The groups did not differ significantly regarding the study variable before the study. However, immediately and two months after the study, the mean body weight gain and self-efficacy in the experimental group were significantly lower and higher, respectively, than the control group (p < 0.05). Implementing a self-efficacy promotion training programme is effective in decreasing weight gain and increasing self-efficacy in patients undergoing haemodialysis. Nurses in haemodialysis units can use self-efficacy promotion training programmes as an effective intervention for improving patients' outcomes. © 2012 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  7. Changes in quality of life over time--Dutch haemodialysis patients and general population compared.

    PubMed

    Mazairac, Albert H A; de Wit, G Ardine; Penne, E Lars; van der Weerd, Neelke C; de Jong, Boudewijn; Grooteman, Muriel P C; van den Dorpel, Marinus A; Buskens, Erik; Dekker, Friedo W; Nubé, Menso J; Ter Wee, Piet M; Boeschoten, Els W; Bots, Michiel L; Blankestijn, Peter J

    2011-06-01

    Improving the health-related quality of life (HRQOL) for haemodialysis patients is a considerable challenge. The aim of the present study was to compare changes in HRQOL in haemodialysis patients with those observed in the general population over a 10-year period and explore factors that might explain possible differences. We compared 126 haemodialysis patients assessed in 1995 in the Netherlands Cooperative Study on the Adequacy of Dialysis-1 (NECOSAD-I) with 515 patients enrolled in 2006 in the ongoing Convective Transport Study (CONTRAST). Changes in HRQOL in these cohorts were compared with two representative samples from the general Dutch population, assessed in 1992 (n = 1,063) and 2001 (n = 10,600). HRQOL was measured with the SF-36 questionnaire. Differences in HRQOL were analysed with ANCOVA to adjust for demographic variables. To assess possible differences, we used multivariable regression analysis. HRQOL in haemodialysis patients in 2006 [CONTRAST, mean age 63 ± 14 years (SD), 62% male] was significantly better than in 1995 (NECOSAD-I, 59 ± 16 years, 53% male) in four domains of the SF-36: bodily pain (+ 5 points, P = 0.009), vitality (+ 7, P < 0.001), role-emotional (+ 14, P < 0.001) and mental health (+ 8, P < 0.001), after adjusting for demographic variables. This increment could partly be explained by improved haemoglobin and phosphate levels. Compared to the general population, HRQOL improvement was most outspoken in two domains: bodily pain (+ 6, P = 0.01) and role-emotional (+ 8, P = 0.007). This study showed an improvement of HRQOL in haemodialysis patients over an 11-year period of time, independent of global changes in the general population.

  8. COPING SKILLS OF IRANIAN FAMILY CAREGIVERS' IN CARETAKING OF PATIENTS UNDERGOING HAEMODIALYSIS: A QUALITATIVE STUDY.

    PubMed

    Eslami, Ahmad Ali; Rabiei, Leili; Abedi, Heidar Ali; Shirani, Majid; Masoudi, Reza

    2016-09-01

    Coping skills enable caregivers to establish and maintain supportive relationships with the haemodialysis patients they care for. These skills are very important in terms of social support, promotion of mental health and social and family relations. The aim of this study is to investigate the coping skills of Iranian family caregivers as they take care of patients undergoing haemodialysis. Twenty participants were selected for the study through purposive sampling. The data gathering techniques used for the research were in-depth and unstructured interviews. The researchers used an inductive thematic analysis approach to analyse the data generated from the interviews. Four main themes emerged from the data: help-seeking skills, self-nurturing skills, time management skills and stress management skills. The focus of attention was on the stress management coping skills of the caregivers of haemodialysis patients together with their ability to cope with complex problems. Healthcare providers, by taking into account these skills and strategies of empowerment, can help other caregivers of haemodialysis patients cope with their heavy care conditions and better define their purposes in caretaking. © 2016 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  9. Association between human resources and risk of hospitalisation in end-stage renal disease outpatients receiving haemodialysis: a longitudinal cohort study using claim data during 2013-2014.

    PubMed

    Choi, Hoon-Hee; Han, Kyu-Tae; Nam, Chung Mo; Moon, Ki Tae; Kim, Woorim; Park, Eun-Cheol

    2016-08-17

    The number of patients requiring haemodialysis has gradually increased in South Korea. Owing to this growth, concerns have been raised regarding haemodialysis quality of care, and healthcare professionals must consider alternatives for appropriate management of patients with chronic kidney disease (CKD). Therefore, we investigated the association between risk of hospitalisation of outpatients who received haemodialysis due to end-stage renal disease (ESRD) and the human resources of the haemodialysis unit. We used data from National Health Insurance (NHI) claims during October 2013 to September 2014. These data comprised 40 543 outpatients with ESRD (4 751 047 outpatient cases) who received haemodialysis. No interventions were made. We performed Poisson regression analysis using a generalised estimating equation that included both patient and haemodialysis unit characteristics to examine the factors associated with hospitalisation of outpatients with ESRD. Among 4 751 047 outpatient cases, 27 997 (0.59%) were hospitalised during the study period. A higher proportion of haemodialysis patient care specialists and a higher number of nurses experienced in haemodialysis were inversely associated with the risk of hospitalisation (per 10% increase in haemodialysis patient care specialists: relative risk (RR)=0.987, 95% CI 0.981 to 0.993; per 10-person increase in nurses who provided haemodialysis: RR=0.876, 95% CI 0.833 to 0.921). In addition, such associations were greater in severe patients. Our findings suggest that haemodialysis units with high-quality, haemodialysis-specialised human resources could positively affect the outcomes of outpatients with ESRD. Based on our findings, health policymakers and professionals should implement strategies for the optimal management of patients with CKD. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Thinking ahead--the need for early Advance Care Planning for people on haemodialysis: A qualitative interview study.

    PubMed

    Bristowe, Katherine; Horsley, Helen L; Shepherd, Kate; Brown, Heather; Carey, Irene; Matthews, Beverley; O'Donoghue, Donal; Vinen, Katie; Murtagh, Felicity E M

    2015-05-01

    There is a need to improve end-of-life care for people with end-stage kidney disease, particularly due to the increasingly elderly, frail and co-morbid end-stage kidney disease population. Timely, sensitive and individualised Advance Care Planning discussions are acceptable and beneficial for people with end-stage kidney disease and can help foster realistic hopes and goals. To explore the experiences of people with end-stage kidney disease regarding starting haemodialysis, its impact on quality of life and their preferences for future care and to explore the Advance Care Planning needs of this population and the timing of this support. Semi-structured qualitative interview study of people receiving haemodialysis. Interviews were analysed using thematic analysis. Recruitment ceased once data saturation was achieved. A total of 20 patients at two UK National Health Service hospitals, purposively sampled by age, time on haemodialysis and symptom burden. Themes emerged around: Looking Back, emotions of commencing haemodialysis; Current Experiences, illness and treatment burdens; and Looking Ahead, facing the realities. Challenges throughout the trajectory included getting information, communicating with staff and the 'conveyor belt' culture of haemodialysis units. Participants reported a lack of opportunity to discuss their future, particularly if their health deteriorated, and variable involvement in treatment decisions. However, discussion of these sensitive issues was more acceptable to some than others. Renal patients have considerable unmet Advance Care Planning needs. There is a need to normalise discussions about preferences and priorities in renal and haemodialysis units earlier in the disease trajectory. However, an individualised approach is essential - one size does not fit all. © The Author(s) 2014.

  11. Advance care planning for haemodialysis patients.

    PubMed

    Lim, Chi Eung Danforn; Ng, Rachel W C; Cheng, Nga Chong Lisa; Cigolini, Maria; Kwok, Cannas; Brennan, Frank

    2016-07-26

    End-stage kidney disease (ESKD) is a chronic, debilitative and progressive illness that may need interventions such as dialysis, transplantation, dietary and fluid restrictions. Most patients with ESKD will require renal replacement therapy, such as kidney transplantation or maintenance dialysis. Advance care planning traditionally encompass instructions via living wills, and concern patient preferences about interventions such as cardiopulmonary resuscitation and feeding tubes, or circumstances around assigning surrogate decision makers. Most people undergoing haemodialysis are not aware of advance care planning and few patients formalise their wishes as advance directives and of those who do, many do not discuss their decisions with a physician. Advance care planning involves planning for future healthcare decisions and preferences of the patient in advance while comprehension is intact. It is an essential part of good palliative care that likely improves the lives and deaths of haemodialysis patients. The objective of this review was to determine whether advance care planning in haemodialysis patients, compared with no or less structured forms of advance care planning, can result in fewer hospital admissions or less use of treatments with life-prolonging or curative intent, and if patient's wishes were followed at end-of-life. We searched the Cochrane Kidney and Transplant Specialised Register to 27 June 2016 through contact with the Information Specialist using search terms relevant to this review. We also searched the Cumulative Index of Nursing and Allied Health Literature (CINAHL), and Social Work Abstracts (OvidSP). All randomised controlled trials (RCTs) and quasi-RCTs (RCTs in which allocation to treatment was obtained by alternation, use of alternate medical records, date of birth or other predictable methods) looking at advance care planning versus no form of advance care planning in haemodialysis patients was considered for inclusion without language

  12. Magnetic resonance imaging classification of haemodialysis-related amyloidosis of the shoulder: risk factors and arthroscopic treatment.

    PubMed

    Ando, Akira; Hagiwara, Yoshihiro; Sekiguchi, Takuya; Koide, Masashi; Kanazawa, Kenji; Watanabe, Takashi; Itoi, Eiji

    2017-07-01

    This study proposed new magnetic resonance imaging (MRI) of haemodialysis shoulders (HDS) focusing on the changes of the rotator cuff, and rotator interval and risk factors for the development of HDS were examined. Eighty-five shoulders in 72 patients with a chief complaint of shoulder pain during haemodialysis and at least 10 years of haemodialysis were included. They were classified into 5 groups based on the thickness of the rotator cuff and conditions of rotator interval. Clinical and radiological findings in each grade were examined, and risk factors for the development of HDS were evaluated. Arthroscopic surgeries were performed on 22 shoulders in 20 patients, and arthroscopic findings were also evaluated. Positive correlations for the development of HDS were observed in duration of haemodialysis, positive hepatitis C virus (HCV) infection, and previous haemodialysis-related orthopaedic surgery (P < 0.001, respectively). Strong correlations were observed between positive HCV and the progression of HDS (odds ratio 24.8, 95 % confidence interval 5.7-107.6). Arthroscopically, progression of the surrounding soft tissue degeneration was observed, and operative times were lengthened depending on the progression of MRI grading. A new MRI classification of HDS which may be helpful when considering arthroscopic surgeries has been proposed. Positive HCV infection was strongly associated with the progression of HDS on MRI. Conditions of the rotator interval and the rotator cuff based on the MRI classification should be examined when treating HDS patients. III.

  13. Clinical, analytical and bioimpedance characteristics of persistently overhydrated haemodialysis patients.

    PubMed

    Castellano, Sandra; Palomares, Inés; Molina, Manuel; Pérez-García, Rafael; Aljama, Pedro; Ramos, Rosa; Merello, J Ignacio

    2014-11-17

    Fluid overload is an important and modifiable cardiovascular risk factor for haemodialysis patients. So far, the diagnosis was based on clinical methods alone. Nowadays, we have new tools to assess more objectively the hydration status of the patients on haemodialysis, as BCM (Body Composition Monitor). A Relative Overhydration (AvROH) higher than 15% (it means, Absolute Overhydration or AWOH higher than 2.5 Litres) is associated to greater risk in haemodialysis. However, there is a group of maintained hyperhydrated patients. The aim of the present study is to identify the characteristics of patients with maintained hyperhydrated status (AvROH higher than 15% or AWOH higher than 2.5 liters). The secondary aim is to show the hemodynamic and analytical changes that are related to the reduction in hyperhydration status. Longitudinal cohort study during six months in 2959 patients in haemodialysis (HD) that are grouped according to their hydration status by BCM. And we compare their clinical, analytical and bioimpedance spectroscopy parameters. The change in overhydration status is followed by a decrease in blood pressure and the need for hypotensive drugs (AHT) and erythropoiesis stimulating agents (ESA). The target hydration status is not reached by two subgroups of patients. First, in diabetic patients with a high comorbidity index and high number of hypotensive drugs (AHT) but a great positive sodium gradient during dialysis sessions; and, younger non-diabetic patients with longer time on hemodialysis and positive sodium gradient, lower fat tissue index (FTI) but similar lean tissue index (LTI) and albumin than those with a reduction in hyperhydration status. Those patients with a reduction in hyperhydration status, also show a better control in blood pressure and anemia with less number of AHT and ESA. The maintained hyperhydrated patients, diabetic patients with many comorbidities and young men patients with longer time on hemodialysis and non-adherence treatment

  14. Nonadherence to Medication Therapy in Haemodialysis Patients: A Systematic Review

    PubMed Central

    Ghimire, Saurav; Castelino, Ronald L.; Lioufas, Nicole M.; Peterson, Gregory M.; Zaidi, Syed Tabish R.

    2015-01-01

    Background End-stage kidney disease (ESKD) patients are often prescribed multiple medications. Together with a demanding weekly schedule of dialysis sessions, increased number of medicines and associated regimen complexity pre-dispose them at high risk of medication nonadherence. This review summarizes existing literature on nonadherence and identifies factors associated with nonadherence to medication therapy in patients undergoing haemodialysis. Methods A comprehensive search of PubMed, Embase, CINAHL, PsycInfo, and Cochrane Database of Systematic Reviews covering the period from 1970 through November 2014 was performed following a predefined inclusion and exclusion criteria. Reference lists from relevant materials were reviewed. Data on study characteristics, measures of nonadherence, prevalence rates and factors associated with nonadherence were collected. The Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines was followed in conducting this systematic review. Results Of 920 relevant publications, 44 were included. The prevalence of medication nonadherence varied from 12.5% to 98.6%, with widespread heterogeneity in measures and definitions employed. Most common patient-related factors significantly associated with nonadherence were younger age, non-Caucasian ethnicity, illness interfering family life, being a smoker, and living single and being divorced or widowed. Similarly, disease-related factors include longevity of haemodialysis, recurrent hospitalization, depressive symptoms and having concomitant illness like diabetes and hypertension. Medication-related factors such as daily tablet count, total pill burden, number of phosphate binders prescribed and complexity of medication regimen were also associated with poor adherence. Conclusions A number of patient-, disease-, and medication-related factors are associated with medication nonadherence in haemodialysis patients. Clinicians should be aware of such factors so that

  15. Patient satisfaction with in-centre haemodialysis care: an international survey

    PubMed Central

    Palmer, Suetonia C; de Berardis, Giorgia; Craig, Jonathan C; Tong, Allison; Tonelli, Marcello; Pellegrini, Fabio; Ruospo, Marinella; Hegbrant, Jörgen; Wollheim, Charlotta; Celia, Eduardo; Gelfman, Ruben; Ferrari, Juan Nin; Törok, Marietta; Murgo, Marco; Leal, Miguel; Bednarek-Skublewska, Anna; Dulawa, Jan; Strippoli, Giovanni F M

    2014-01-01

    Objectives To evaluate patient experiences of specific aspects of haemodialysis care across several countries. Design Cross-sectional survey using the Choices for Healthy Outcomes in Caring for End-Stage Renal Disease (CHOICE) questionnaire. Setting Haemodialysis clinics within a single provider in Europe and South America. Participants 2748 adults treated in haemodialysis. Primary and secondary outcomes The primary outcome was patient satisfaction with overall care. Secondary outcomes included patient experiences of individual aspects of dialysis care. Results 2145 (78.1%) adults responded to the questionnaire. Fewer than half (46.5% (95% CI 44.5% to 48.6%)) rated their overall care as excellent. Global perceptions of care were uninfluenced by most respondent characteristics except age and depressive symptoms; older respondents were less critical of their care (adjusted OR for excellent rating 1.44 (1.01 to 2.04)) and those with depressive symptoms were less satisfied (0.56 (0.44 to 0.71)). Aspects of care that respondents most frequently ranked as excellent were staff attention to dialysis vascular access (54% (52% to 56%)); caring of nurses (53% (51% to 55%)); staff responsiveness to pain or discomfort (51% (49% to 53%)); caring, helpfulness and sensitivity of dialysis staff (50% (48% to 52%)); and ease of reaching dialysis staff by telephone (48% (46% to 50%)). The aspects of care least frequently ranked as excellent were information provided when choosing a dialysis modality (23% (21% to 25%)), ease of seeing a social worker (28% (24% to 32%)), information provided about dialysis (34% (32% to 36%)), accuracy of information from nephrologist (eg, about prognosis or likelihood of a kidney transplant; 37% (35% to 39%)) and accuracy of nephrologists’ instructions (39% (36% to 41%)). Conclusions Haemodialysis patients are least satisfied with the complex aspects of care. Patients’ expectations for accurate information, prognosis, the likelihood of kidney

  16. Patient satisfaction with in-centre haemodialysis care: an international survey.

    PubMed

    Palmer, Suetonia C; de Berardis, Giorgia; Craig, Jonathan C; Tong, Allison; Tonelli, Marcello; Pellegrini, Fabio; Ruospo, Marinella; Hegbrant, Jörgen; Wollheim, Charlotta; Celia, Eduardo; Gelfman, Ruben; Ferrari, Juan Nin; Törok, Marietta; Murgo, Marco; Leal, Miguel; Bednarek-Skublewska, Anna; Dulawa, Jan; Strippoli, Giovanni F M

    2014-05-19

    To evaluate patient experiences of specific aspects of haemodialysis care across several countries. Cross-sectional survey using the Choices for Healthy Outcomes in Caring for End-Stage Renal Disease (CHOICE) questionnaire. Haemodialysis clinics within a single provider in Europe and South America. 2748 adults treated in haemodialysis. The primary outcome was patient satisfaction with overall care. Secondary outcomes included patient experiences of individual aspects of dialysis care. 2145 (78.1%) adults responded to the questionnaire. Fewer than half (46.5% (95% CI 44.5% to 48.6%)) rated their overall care as excellent. Global perceptions of care were uninfluenced by most respondent characteristics except age and depressive symptoms; older respondents were less critical of their care (adjusted OR for excellent rating 1.44 (1.01 to 2.04)) and those with depressive symptoms were less satisfied (0.56 (0.44 to 0.71)). Aspects of care that respondents most frequently ranked as excellent were staff attention to dialysis vascular access (54% (52% to 56%)); caring of nurses (53% (51% to 55%)); staff responsiveness to pain or discomfort (51% (49% to 53%)); caring, helpfulness and sensitivity of dialysis staff (50% (48% to 52%)); and ease of reaching dialysis staff by telephone (48% (46% to 50%)). The aspects of care least frequently ranked as excellent were information provided when choosing a dialysis modality (23% (21% to 25%)), ease of seeing a social worker (28% (24% to 32%)), information provided about dialysis (34% (32% to 36%)), accuracy of information from nephrologist (eg, about prognosis or likelihood of a kidney transplant; 37% (35% to 39%)) and accuracy of nephrologists' instructions (39% (36% to 41%)). Haemodialysis patients are least satisfied with the complex aspects of care. Patients' expectations for accurate information, prognosis, the likelihood of kidney transplantation and their options when choosing dialysis treatment need to be considered when

  17. A study of dietary knowledge and its religious relationship in patients receiving haemodialysis.

    PubMed

    Giaramazidou, T; Giovreki, A; Morfakidou, L; Iliou, C; Karapanagiotou, P

    2005-01-01

    It is widely known that haemodialysis patients do not readily comply with nutrition guidance. At least 6 months after initiating haemodialysis, the patients' dietary knowledge was tested by use of a questionnaire. The relationship between patient dietary compliance and religion and educational level was studied. Seventy patients were included in the study (33 Christians and 37 Muslims), ages ranging from 24 to 87 years. All patients had received haemodialysis for a period of the time ranging from 6 to 216 months. The questionnaire included questions related to salt, potassium and phosphate. Regarding questions, concerning salt, the Christians answered 85.7 +/- 22.8% correctly whilst the Muslims answered 60.1 +/- 34.6% correctly, a difference which was statistically significant (p=0.0001). However, more Christians arrived at the hospital with pulmonary oedema over a two-year period for emergency haemodialysis than Muslims (p=0.017), whilst there was no difference in the number of patients with residual diuresis between the two groups (p=NS). The difference in the incidence of pulmonary oedema could be attributed to the fact that more Christians had heart failure than Muslims (12/33 vs 6/37, p=0.09). Regarding questions concerning potassium, the Christians answered 74.6 +/- 33.9% correctly whilst the Muslims answered 41.1 +/- 38.5% correctly, a difference that was statistically significant (p=0.0001). However despite this difference, no Muslims attended hospital for emergency haemodialysis related to hyperkalaemia over the two-year period. Finally, regarding questions concerning phosphates, the answers from both group of patients were disappointing. Specifically, Christians answered 49.1 +/- 43% correctly, whilst Muslims answered 19.1 +/- 3.3% of the questions correctly, a difference which was statistically significant (p=0.0001). Patients did not acquire the necessary dietary knowledge but despite insufficient knowledge, they had a low incidence of fluid overload

  18. Association between human resources and risk of hospitalisation in end-stage renal disease outpatients receiving haemodialysis: a longitudinal cohort study using claim data during 2013–2014

    PubMed Central

    Choi, Hoon-Hee; Han, Kyu-Tae; Nam, Chung Mo; Moon, Ki Tae; Kim, Woorim; Park, Eun-Cheol

    2016-01-01

    Objective The number of patients requiring haemodialysis has gradually increased in South Korea. Owing to this growth, concerns have been raised regarding haemodialysis quality of care, and healthcare professionals must consider alternatives for appropriate management of patients with chronic kidney disease (CKD). Therefore, we investigated the association between risk of hospitalisation of outpatients who received haemodialysis due to end-stage renal disease (ESRD) and the human resources of the haemodialysis unit. Setting We used data from National Health Insurance (NHI) claims during October 2013 to September 2014. Participants These data comprised 40 543 outpatients with ESRD (4 751 047 outpatient cases) who received haemodialysis. Interventions No interventions were made. Outcome measure We performed Poisson regression analysis using a generalised estimating equation that included both patient and haemodialysis unit characteristics to examine the factors associated with hospitalisation of outpatients with ESRD. Results Among 4 751 047 outpatient cases, 27 997 (0.59%) were hospitalised during the study period. A higher proportion of haemodialysis patient care specialists and a higher number of nurses experienced in haemodialysis were inversely associated with the risk of hospitalisation (per 10% increase in haemodialysis patient care specialists: relative risk (RR)=0.987, 95% CI 0.981 to 0.993; per 10-person increase in nurses who provided haemodialysis: RR=0.876, 95% CI 0.833 to 0.921). In addition, such associations were greater in severe patients. Conclusions Our findings suggest that haemodialysis units with high-quality, haemodialysis-specialised human resources could positively affect the outcomes of outpatients with ESRD. Based on our findings, health policymakers and professionals should implement strategies for the optimal management of patients with CKD. PMID:27534988

  19. The effect of aromatherapy on haemodialysis patients' pruritus.

    PubMed

    Cürcani, Mehtap; Tan, Mehtap

    2014-12-01

    To determine the effect of aromatherapy on pruritus observed in haemodialysis patients. Although the prevalence of pruritus in kidney failure has decreased in the recent years, pruritus is a difficult and serious problem which concerns the majority of haemodialysis patents and is hard to cure. A prospective, pretest-post-test quasi-experimental design was used. The research is quasi-experimental clinical trial conducted as pretest and post-test with control groups between January 2011-April 2012, in haemodialysis units of hospitals in Erzurum. The collection of the data is achieved using a questionnaire to detect the patients' individual and pruritus score scale and to clarify certain laboratory parameters regarding the pruritus. Chi-square analysis and t-test are used for the analysis of data. The experimental group's mean post-test pruritus scores (7·20 ± 3·14) were found to be lower than that of control group patients (10·00 ± 2·47), and a highly significant difference was found between the groups (p < 0·001). In the between-groups comparisons of experimental and control group's laboratory parameters, the experimental group's post-test blood urea nitrogen levels (118·26 ± 36·76) were found to be lower than that of control group patients (138·80 ± 48·69), and the between-groups difference was found to be statistically significant (p < 0·05). The results demonstrate that aromatherapy was found to decrease the pruritus problem of haemodialyses patients and led to positive changes in some laboratory parameters related to pruritus. One of the roles of health professionals is to advise individuals, who are living on this problem, using the nonpharmacological methods in checking the itching. By preventing or reducing uraemic pruritus, aromatherapy may also improve quality of life in this patient group. © 2014 John Wiley & Sons Ltd.

  20. Reinforced aneurysmorrhaphy for true aneurysmal haemodialysis vascular access.

    PubMed

    Rokošný, S; Baláž, P; Wohlfahrt, P; Palouš, D; Janoušek, L

    2014-04-01

    In 2008, a new technique of reinforced aneurysmorrhaphy with a polyester mesh tube for salvaging true aneurysmal arteriovenous (AV) haemodialysis access was described by us. In this study, the long-term patency and complication rates associated with this procedure were analysed, and the effect of reinforced aneurysmorrhaphy on high-flow vascular access was assessed. This was a retrospective non-randomised study with prospectively collected data performed at a single centre. Patients with true aneurysmal haemodialysis AV access who underwent aneurysmorrhaphy with external mesh prosthesis between March 2007 and October 2012 were included. Clinical assessment and duplex ultrasound were performed preoperatively, 1, 3, and 12 months postoperatively, and annually thereafter. Data from 62 patients (median age 60 years, range 28-81 years; 63% men) were analysed. The commonest indication was high-flow vascular access associated with the risk of high output cardiac failure (24 patients, 39%). The mean follow-up time was 14.66 ± 12.80 months. Primary patency rates at 6 and 12 months were 86% and 79% respectively. Assisted primary patency rates at 6 and 12 months were 89% and 80% respectively. In 23 patients (96%) operated on for high-flow vascular access, decreased vascular access flow was observed after the procedure. The average flow reduction after aneurysmorrhaphy was 2,197 mL/minute. Postoperative bleeding and infection necessitating surgical revision occurred in three (4.8%) and three (4.8%) patients respectively. Reinforced aneurysmorrhaphy with an external mesh prosthesis is an effective method for treating true aneurysmal haemodialysis AV access, with excellent long-term patency and minimal complications due to infection. Copyright © 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Psychosocial influencers and mediators of treatment adherence in haemodialysis patients.

    PubMed

    Oh, Hyun Soo; Park, Ji Suk; Seo, Wha Sook

    2013-09-01

    This article is a report of the development and testing of the hypothetical model that illustrates relationships between treatment adherence and its psychosocial influencing factors and to elucidate the direct and indirect (mediating) effects of factors on treatment adherence. Poor adherence has been consistently reported in haemodialysis patients. Much research has showed various influencing factors of adherence, but these studies have failed to identify consistent influencing factors. This study was performed using a non-experimental, cross-sectional design. The study subjects were 150 end-stage renal failure patients on haemodialysis at a university hospital located in Incheon, South Korea. Data were collected over 10 months (June 2010-April 2011). The hypothetical model provided a good fit with data. Haemodialysis-related knowledge, perceived barrier to adherence, self-efficacy on adherence, and healthcare provider support had significant effects on adherence. Self-efficacy was found to mediate barrier-adherence and family support-adherence relationships. Self-efficacy in combination with barrier, family support, and healthcare provider support was found to mediate the depression-adherence relationship. Strategies aimed at the development of successful adherence interventions should focus on reducing perceived barriers and enhancing self-efficacy and knowledge. It can be suggested that efforts to improve the healthcare provider-patient relationship would enhance adherence. In depressive patients, strategies that promote self-efficacy and the support of family or healthcare providers could diminish the negative impact of depression on adherence. © 2013 Blackwell Publishing Ltd.

  2. Sleep disturbance and depressive affect in patients treated with haemodialysis.

    PubMed

    Maung, Stephanie; Sara, Ammar El; Cohen, Danielle; Chapman, Cherylle; Saggi, Subodh; Cukor, Daniel

    2017-03-01

    Sleep disorders and depression are prevalent conditions in patients with end-stage kidney disease. These co-morbidities have significant overlap and compounded morbidity and mortality burden. This overlap presents challenges to optimal clinical assessment and treatment. The goal of this study was to assess the prevalence of sleep disturbance in patients on maintenance haemodialysis, and to assess the impact of depressive affect. This was a single-site, single group, cross-sectional study of 69 English-speaking patients undergoing maintenance haemodialysis. Self-reported assessments included those of sleep quality (Pittsburgh Sleep Quality Index), depression (Beck Depression Inventory), daytime sleepiness (Epworth's Sleepiness Scale), a dialysis-specific sleep questionnaire, and standard laboratory values. No objective sleep information was collected. All participants were well dialysed, and represented all four daily shifts. Fifty-eight per cent reported clinically significant sleep difficulty, with elevated yet sub-threshold daytime sleepiness. Mean depressive affect was also elevated, yet sub-diagnostic and was positively correlated with increased age. Participants scoring above the diagnostic threshold for depression had significantly more disturbed sleep quality, more daytime sleepiness and had more problems sleeping due to restless leg syndrome than people with minimal depressive affect. Poor sleep quality is prevalent in patients on maintenance haemodialysis, and is associated with increased daytime sleepiness. Depression further compounds this relationship, and is significantly associated with increased daytime sleepiness and restless leg syndrome. © 2016 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  3. Flash pulmonary oedema after relief of haemodialysis graft stenosis.

    PubMed

    Vélez-Martínez, Mariella; Weinberg, Brent D; Mishkin, Joseph D

    2013-08-01

    Heart failure (HF) and chronic kidney disease (CKD) are undoubtedly very much interrelated, especially in patients with end-stage renal disease (ESRD) who are dependent on renal replacement therapy. Haemodialysis (HD) is of particular interest in cardiovascular patients due to the creation of a haemodialysis vascular access and the haemodynamic changes associated with it. Adequate HD though is very dependent on a properly functioning vascular access. Unfortunately, these surgical vascular accesses are vulnerable to stenoses and occlusions. Percutaneous endovascular treatment of these stenoses is often performed and has been found to be safe and effective. Despite its frequent use, acute medical complications of this percutaneous procedure have not been well-documented. In this report, we describe a patient who developed flash pulmonary oedema after balloon angioplasty treatment of an arteriovenous graft (AVG) stenosis. Copyright © 2012 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  4. Thinking ahead – the need for early Advance Care Planning for people on haemodialysis: A qualitative interview study

    PubMed Central

    Horsley, Helen L; Shepherd, Kate; Brown, Heather; Carey, Irene; Matthews, Beverley; O’Donoghue, Donal; Vinen, Katie; Murtagh, Felicity EM

    2015-01-01

    Background: There is a need to improve end-of-life care for people with end-stage kidney disease, particularly due to the increasingly elderly, frail and co-morbid end-stage kidney disease population. Timely, sensitive and individualised Advance Care Planning discussions are acceptable and beneficial for people with end-stage kidney disease and can help foster realistic hopes and goals. Aim: To explore the experiences of people with end-stage kidney disease regarding starting haemodialysis, its impact on quality of life and their preferences for future care and to explore the Advance Care Planning needs of this population and the timing of this support. Study design: Semi-structured qualitative interview study of people receiving haemodialysis. Interviews were analysed using thematic analysis. Recruitment ceased once data saturation was achieved. Setting/participants: A total of 20 patients at two UK National Health Service hospitals, purposively sampled by age, time on haemodialysis and symptom burden. Results: Themes emerged around: Looking Back, emotions of commencing haemodialysis; Current Experiences, illness and treatment burdens; and Looking Ahead, facing the realities. Challenges throughout the trajectory included getting information, communicating with staff and the ‘conveyor belt’ culture of haemodialysis units. Participants reported a lack of opportunity to discuss their future, particularly if their health deteriorated, and variable involvement in treatment decisions. However, discussion of these sensitive issues was more acceptable to some than others. Conclusion: Renal patients have considerable unmet Advance Care Planning needs. There is a need to normalise discussions about preferences and priorities in renal and haemodialysis units earlier in the disease trajectory. However, an individualised approach is essential – one size does not fit all. PMID:25527527

  5. A holistic approach to factors affecting depression in haemodialysis patients.

    PubMed

    Gerogianni, Georgia; Kouzoupis, Anastasios; Grapsa, Eirini

    2018-05-19

    Depression in dialysis populations is affected by co-morbid diseases, such as cardiovascular disease, diabetes, and immune dysfunction, and it also includes high suicide risk and frequent hospitalizations. Depressive disorders have a close association with malnutrition and chronic inflammation, as well as with cognitive impairment. Impaired cognitive function may be manifested as low adherence to dialysis treatment, leading to malnutrition. Additionally, chronic pain and low quality of sleep lead to high rates of depressive symptoms in haemodialysis patients, while an untreated depression can cause sleep disturbances and increased mortality risk. Depression can also lead to sexual dysfunction and non-adherence, while unemployment can cause depressive disorders, due to patients' feelings of being a financial burden on their family. The present review provides a holistic approach to the factors affecting depression in haemodialysis, offering significant knowledge to renal professionals.

  6. Medication adherence perspectives in haemodialysis patients: a qualitative study.

    PubMed

    Ghimire, Saurav; Castelino, Ronald L; Jose, Matthew D; Zaidi, Syed Tabish R

    2017-05-22

    End-stage kidney disease patients undergoing haemodialysis are prescribed with multiple complex regimens and are predisposed to high risk of medication nonadherence. The aims of this study were to explore factors associated with medication adherence, and, to examine the differential perspectives on medication-taking behaviour shown by adherent and nonadherent haemodialysis patients. A qualitative exploratory design was used. One-on-one semi-structured interviews were conducted with 30 haemodialysis patients at the outpatient dialysis facility in Hobart, Australia. Patient self-reported adherence was measured using 4-item Morisky Green Levine scale. Interview transcripts were thematically analysed and mapped against the World Health Organization (WHO) determinants of medication adherence. Participants were 44-84 years old, and were prescribed with 4-19 medications daily. More than half of the participants were nonadherent to their medications based on self-reported measure (56.7%, n = 17). Themes mapped against WHO adherence model comprised of patient-related (knowledge, awareness, attitude, self-efficacy, action control, and facilitation); health system/ healthcare team related (quality of interaction, and mistrust and collateral arrangements); therapy-related (physical characteristics of medicines, packaging, and side effects); condition-related (symptom severity); and social/ economic factors (access to medicines, and relative affordability). Patients expressed a number of concerns that led to nonadherence behaviour. Many of the issues identified were patient-related and potentially modifiable by using psycho-educational or cognitive-behavioural interventions. Healthcare professionals should be more vigilant towards identifying these concerns to address adherence issues. Future research should be aimed at understanding healthcare professionals' perceptions and practices of assessing medication adherence in dialysis patients that may guide intervention to

  7. The prehistory of haemodialysis as a treatment for uraemia.

    PubMed

    Cameron, J Stewart

    2016-02-01

    Less is generally known about the ideas, events and personalities which drove developments permitting the evolution of haemodialysis as a clinically useful form of palliation and treatment, than its subsequent success and failures. This pre-history of haemodialysis is summarized here. One must remember that with hindsight we can now discern connections between ideas and developments which were not perceptible in their time, and that progress towards any new idea, material or piece of hardware was usually random and undirected, and outcomes uncertain. We must also remember the many blind alleys we can now safely ignore, to give a spurious continuity to the development of ideas. The prehistory of dialysis begins with study of the diffusion of solute and solvent in osmosis in living systems and experimental settings, and the retention of potentially toxic substances in kidney failure, during the 18th and early 19th centuries. These two areas came together in work in the mid-19th century on diffusion of gases and liquids, and showed that natural and synthetic membranes could selectively hinder different solutes. This explained osmosis and allowed semi-permeable membranes to be used and designed. These ideas underpinned the subsequent history of both dialysis using body cavities such as the peritoneum (not discussed here) and ex vivo dialysis of blood. To perform this, new membranes and anticoagulants were needed. These led to the first attempts in animals in 1912-3, and human patients in 1924-8, but only the purification and synthesis of newer materials such as cellulose and heparin allowed practical and successful haemodialysis to evolve in the 1940s.

  8. Conserving water in and applying solar power to haemodialysis: 'green dialysis' through wiser resource utilization.

    PubMed

    Agar, John W M

    2010-06-01

    Natural resources are under worldwide pressure, water and sustainable energy being the paramount issues. Haemodialysis, a water-voracious and energy-hungry healthcare procedure, thoughtlessly wastes water and leaves a heavy carbon footprint. In our service, 100 000 L/week of previously discarded reverse osmosis reject water--water which satisfies all World Health Organisation criteria for potable (drinking) water--no longer drains to waste but is captured for reuse. Reject water from the hospital-based dialysis unit provides autoclave steam for instrument sterilization, ward toilet flushing, janitor stations and garden maintenance. Satellite centre reject water is tanker-trucked to community sporting fields, schools and aged-care gardens. Home-based nocturnal dialysis patient reuse reject water for home domestic utilities, gardens and animal watering. Although these and other potential water reuse practices should be mandated through legislation for all dialysis services, this is yet to occur. In addition, we now are piloting the use of solar power for the reverse osmosis plant and the dialysis machines in our home dialysis training service. If previously attempted, these have yet to be reported. After measuring the power requirements of both dialytic processes and modelling the projected costs, a programme has begun to solar power all dialysis-related equipment in a three-station home haemodialysis training unit. Income-generation with the national electricity grid via a grid-share and reimbursement arrangement predicts a revenue stream back to the dialysis service. Dialysis services must no longer ignore the non-medical aspects of their programmes but plan, trial, implement and embrace 'green dialysis' resource management practices.

  9. Anaemia management protocols in the care of haemodialysis patients: examining patient outcomes.

    PubMed

    Saunders, Sushila; MacLeod, Martha L P; Salyers, Vince; MacMillan, Peter D; Ogborn, Malcolm R

    2013-08-01

    To determine whether the use of a nurse-driven protocol in the haemodialysis setting is as safe and effective as traditional physician-driven approaches to anaemia management. The role of haemodialysis nurses in renal anaemia management has evolved through the implementation of nurse-driven protocols, addressing the trend of exceeding haemoglobin targets and rising costs of erythropoietin-stimulating agents. Retrospective, non-equivalent case control group design. The sample was from three haemodialysis units in a control group (n = 64) and three haemodialysis units in a protocol group (n = 43). The protocol group used a nurse-driven renal anaemia management protocol, while the control group used a traditional physician-driven approach to renal anaemia management. All retrospective data were obtained from a provincial renal database. Data were analysed using chi-square tests and t-tests. Patient outcomes examined were haemoglobin levels, transferrin saturation levels, erythropoietin-stimulating agents use and intravenous iron use. Cost comparisons were determined using average use of erythropoietin-stimulating agents and intravenous iron. Control and protocol groups reached haemoglobin target levels. In the protocol group, 75% reached transferrin saturation target levels in comparison with 25% of the control group. Use and costs for iron was higher in the control group, while use and costs for erythropoietin was higher in the protocol group. The higher usage of erythropoietin-stimulating agents was potentially related to comorbid conditions amongst the protocol group. A nurse-driven protocol approach to renal anaemia management was as effective as the physician-driven approach in reaching haemoglobin and transferrin saturation levels. Further examination of the use and dosing of erythropoietin-stimulating agents and intravenous iron, their impact on haemoglobin levels related to patient comorbidities and subsequent cost effectiveness of protocols is required. Using

  10. Travel-associated acquisition of hepatitis C virus infection in patients receiving haemodialysis.

    PubMed

    Ghafur, Abdul; Raza, Muhammad; Labbett, Wendy; Chawla, Anuradha; Smith, Colette; Ngui, Siew Lin; Davenport, Andrew; Geretti, Anna Maria

    2007-09-01

    It has been proposed that hepatitis C virus (HCV)-infected patients with end-stage renal disease undergoing maintenance haemodialysis may lack HCV antibody (anti-HCV) despite chronic HCV viraemia. This carries important implications for the design of surveillance policies. To characterize the prevalence of antibody-negative/RNA-positive HCV infection, patients attending seven haemodialysis units underwent anti-HCV testing using a third-generation assay and HCV RNA testing using real-time PCR. At screening, anti-HCV prevalence was 12/360 (3.3%; 95% CI 1.7-5.8%); 7/12 (58.3%) anti-HCV positive samples were HCV RNA positive. Among anti-HCV-negative samples, 2/348 (0.6%; 95% CI 0.2-2.1%) tested HCV RNA positive (genotype 1a). Retrospective testing of stored sera dated the infections to a period of holiday in the Indian subcontinent. The two infections were unrelated by HCV-NS5B sequencing. Only one of the two newly infected persons showed raised transaminases. Both developed anti-HCV within 8-13 weeks of follow-up. Prospective surveillance of travellers to resource-limited countries returning to the units showed a HCV incidence of 4/153 travel episodes (2.6%; 95% CI 0.7-6.6%) among 131 persons (3.1%; 95% CI 0.8-7.6%). Among haemodialysis patients in the United Kingdom, antibody-negative/RNA-positive HCV status is associated with newly acquired infection, rather than lack of antibody responses in chronic HCV infection. There is a significant risk of HCV infection associated with travel to resource-limited countries. Given that transaminase levels may be normal, HCV RNA testing is recommended in patients re-entering a dialysis unit following haemodialysis in settings where suboptimal infection control policies pose a risk of exposure to blood-borne viruses.

  11. Illness perceptions predict survival in haemodialysis patients.

    PubMed

    Chilcot, Joseph; Wellsted, David; Farrington, Ken

    2011-01-01

    Illness perceptions have been shown to be important determinants of functional and psychosocial outcomes, including quality of life and treatment adherence in end-stage renal disease patients. The aim of this prospective study was to determine whether haemodialysis patients' illness perceptions impact upon survival. Haemodialysis patients from a UK renal service completed the Revised Illness Perception Questionnaire. Over the study period (May 2007 to December 2010), all-cause mortality was recorded as the endpoint. 223 patients were followed up for a median of 15.9 months (min. 10 days, max. 42.7 months). The median dialysis vintage was 17.6 months (min. 4 days, max. 391.3 months). Treatment control perceptions demonstrated a significant association with mortality (HR = 0.91, 95% CI: 0.83-0.99, p = 0.03). After controlling for covariates, including age, albumin, extra renal comorbidity and depression scores, perception of treatment control remained a significant predictor of mortality (HR = 0.89, 95% CI: 0.80-0.99, p = 0.03). Patients' perceptions of treatment control (dialysis therapy) predict survival independently of survival risk factors, including comorbidity. Studies are required to test whether psychological interventions designed to modify maladaptive illness perceptions influence clinical outcomes in this patient setting. Copyright © 2011 S. Karger AG, Basel.

  12. Acute exacerbation of previously undiagnosed chronic focal myositis in an Aboriginal patient on maintenance haemodialysis

    PubMed Central

    Stewart, Benjamin James; Majoni, Sandawana William

    2014-01-01

    We describe a haemodialysis patient who presented with an exacerbation of previously undiagnosed chronic focal myositis during a hospital admission for missed dialysis and chronic foot osteomyelitis. The association of focal myositis with haemodialysis has been reported once previously, but we report the third case in our experience and argue that it is probably more common than previously appreciated. We consider a focused differential diagnosis for a diabetic dialysis patient with leg pain and discuss important features of this rare condition. PMID:25342033

  13. Infective endocarditis in patients on haemodialysis - possible strategies for prevention.

    PubMed

    Oun, Hadi A; Price, Andrew J; Traynor, Jamie P

    2016-05-01

    Infective endocarditis is an important cause of morbidity and mortality in patients receiving haemodialysis for established renal failure. We carried out a prospective audit of patients developing infective endocarditis in a single renal unit. From 1 January 2000 to 31 December 2013, we collected data on all cases of endocarditis occurring in patients receiving haemodialysis at Monklands Hospital, Airdrie. Twenty-nine patients developed endocarditis during our audit period. Twenty-three (79.3%) of the patients had pre-existing cardiac valve abnormalities such as regurgitation or calcification. Staphylococcus aureus was the most common microorganism cultured from the blood of 22 patients (75.9%). MRSA bacteraemia was identified in eight of these patients and all eight patients died during that first presentation. Different strategies were introduced within the unit during the audit period aiming to reduce the rate of bacteraemia. Since 2011, a successful strategy has been introduced under the auspices of the Scottish Patient Safety Programme. This led to our Staph aureus bacteraemia rate related to non-tunnelled venous catheters going from an average of 15 days between episodes to having had no episodes between 2 December 2011 and the end of the study period (760 days). This also appears to have had a positive impact on reducing the rate of endocarditis. Infective endocarditis remains a devastating consequence of bacteraemia in patients receiving haemodialysis. An effective strategy aimed at reducing the rate of bacteraemia appears to have a similar effect on the rate of endocarditis. © The Author(s) 2016.

  14. The Impact of Exercising During Haemodialysis on Blood Pressure, Markers of Cardiac Injury and Systemic Inflammation--Preliminary Results of a Pilot Study.

    PubMed

    Dungey, Maurice; Bishop, Nicolette C; Young, Hannah M L; Burton, James O; Smith, Alice C

    2015-01-01

    Patients requiring haemodialysis have cardiovascular and immune dysfunction. Little is known about the acute effects of exercise during haemodialysis. Exercise has numerous health benefits but in other populations has a profound impact upon blood pressure, inflammation and immune function; therefore having the potential to exacerbate cardiovascular and immune dysfunction in this vulnerable population. Fifteen patients took part in a randomised-crossover study investigating the effect of a 30-min bout of exercise during haemodialysis compared to resting haemodialysis. We assessed blood pressure, plasma markers of cardiac injury and systemic inflammation and neutrophil degranulation. Exercise increased blood pressure immediately post-exercise; however, 1 hour after exercise blood pressure was lower than resting levels (106±22 vs. 117±25 mm Hg). No differences in h-FABP, cTnI, myoglobin or CKMB were observed between trial arms. Exercise did not alter circulating concentrations of IL-6, TNF-α or IL-1ra nor clearly suppress neutrophil function. This study demonstrates fluctuations in blood pressure during haemodialysis in response to exercise. However, since the fall in blood pressure occurred without evidence of cardiac injury, we regard it as a normal response to exercise superimposed onto the haemodynamic response to haemodialysis. Importantly, exercise did not exacerbate systemic inflammation or immune dysfunction; intradialytic exercise was well tolerated. © 2015 The Author(s) Published by S. Karger AG, Basel.

  15. Estimation of quality of life in haemodialysis patients.

    PubMed

    Abraham, S; Ramachandran, A

    2012-11-01

    Since haemodialysis is an expensive treatment modality for chronic renal failure patients, it is very essential to assess the outcome of therapy in terms of quality of life. The primary objective of the study was to estimate the effect of patient counselling in quality of life of end stage renal disease patients opting haemodialysis using World Health Organisation Quality of life scale and to assess the variables affecting the quality of life of these patients. Quality of life was determined by World Health Organisation Quality of life scale questionnaire comprised of 26 items which measures four domains: physical, psychological, social and environmental domain. A total of 81 patients were selected and divided into test and control group and the test group patients received counselling regarding their disease, use of medications, importance of adherence and the complications experienced during and after dialysis. The quality of life data was collected at the interval of 1, 2, 3, 6 and 12 months and the patients were counselled at each interval. The demographic profiles revealed that majority of the patients were in the age group of 31-50 and there exists a male predominance. About the socioeconomic status, upper middle class people were mostly affected. Assessment of impact of patient counselling in the quality of life of haemodialysis indicated a significant improvement in each domain after counselling. And also found that the psychological domain showed a significant increase in the score compared to others. Patient counselling helped to gain benefits in terms of improvement in quality of life and delayed progression of renal failure. Early recognition and prevention is necessary to improve the quality of life of chronic renal failure patients. Patient counselling should be made mandatory by incorporating clinical pharmacist in the nephrology team to make the patient understand his illness and modifications in lifestyle also create a positive environment and

  16. Sudden cardiac death in haemodialysis: clinical epidemiology and mechanisms.

    PubMed

    Banerjee, Debasish

    Sudden cardiac death, which causes premature loss of lives on haemodialysis of the elderly, youths and even children; cannot be prevented, because the aetiology is poorly understood and effective interventions are yet unknown. Improving our knowledge of mechanisms causing sudden cardiac death in haemodialysis patients may help us to design better interventions; and clinical epidemiology of sudden cardiac death could be an important tool to further guide human and animal studies. This review researches the clinical epidemiology of sudden cardiac death to suggest possible mechanisms, although they require further studies. The research shows how traditional cardiovascular risk factors such as age, diabetes and smoking have an impact; non-traditional risk factors such as inflammation, mineral-bone disease and even uraemia itself have higher impact; and how cardiac structural, functional and electrocardiographic markers predict sudden cardiac death in dialysis patients. More in-depth human and animal studies, guided with existing knowledge, are necessary to better understand the mechanisms and design successful interventions. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Baseline characteristics of an incident haemodialysis population in Spain: results from ANSWER—a multicentre, prospective, observational cohort study

    PubMed Central

    Pérez-García, Rafael; Martín-Malo, Alejandro; Fort, Joan; Cuevas, Xavier; Lladós, Fina; Lozano, Javier; García, Fernando

    2009-01-01

    Background. The ANSWER study aims to identify risk factors leading to increased cardiovascular morbidity and mortality in a Spanish incident haemodialysis population. This paper summarizes the baseline characteristics of this population. Methods. A prospective, observational, one-cohort study, including all consecutive incident haemodialysis patients from 147 Spanish nephrology services, was conducted. Patients were enrolled between October 2003 and September 2004. Sociodemographic, clinical, laboratory and health care characteristics were collected. Results. Baseline characteristics are described for 2341 incident haemodialysis patients [mean (SD) age 65.2 (14.5) years, 63% males]. The main cause of renal failure was diabetic nephropathy (26%). The majority of patients (57%) had a Karnofsky score of 80–100 and 27% were followed up by a nephrologist for ≤6 months. In total, 86% of the patients had hypertension, 43% had dyslipidaemia and 44% had a history of cardiovascular disease. Initial vascular access was obtained via a temporary catheter in 30% of patients, via a permanent catheter in 16% and via an arteriovenous fistula in 54%. Albumin levels were <3.5 g/dl in 43% of patients. Immediately prior to the onset of haemodialysis, the mean (SD) glomerular filtration rate (GFR) was 7.6 (2.8) ml/min/1.73 m2, and only 6.7% of the patients were within the K/DOQI guidelines for all four bone mineral markers. In addition, a high proportion of patients had anaemia markers outside the EBPG guidelines (haemoglobin <11 g/dl, 59%, ferritin <100 or >500 ng/ml, 41% and saturated transferrin <20 or >40%, 50%) despite previous treatment with erythropoiesis-stimulating agents in 41% of cases. Conclusions. There is excessive use of temporary catheters and a high prevalence of uraemia-related cardiovascular risk factors among incident haemodialysis patients in Spain. The poor control of hypertension, anaemia, malnutrition and mineral metabolism and late referral to a nephrologist

  18. Defining the culture and attitude towards dietary management actions in people undergoing haemodialysis.

    PubMed

    Onbe, Hiromi; Oka, Michiyo; Shimada, Mikiko; Motegi, Emiko; Motoi, Yuji; Okabe, Ayako

    2013-06-01

    The present study was designed to clarify the structure of culture and the three components of attitude in a desirable attitude toward dietary management actions in outpatient haemodialysis patients who are in the maintenance phase of treatment. The participants in the study included nine patients undergoing chronic maintenance haemodialysis who have received guidance related to diet and had good test results. Ethnography, by means of participant observation and semi-structured interviews, was chosen as the research method. Desirable attitude of haemodialysis patients in dietary management actions was found to have a chronological progression in one of the components of attitude: propensity of behaviour. Change in behaviour was influenced by affect and cognition. At the base of the structure of attitude lay three factors: valuing cooking with seasonal ingredients and creating special meals for seasonal occasions; family draws near, shows care and gives support; and belief in information perceived to be good for the health, which was influenced by three components of attitude: affect, cognition, and propensity of behaviour, as well as culture. Participants continue to value the food culture that they grew up with, which involves their affect towards, and cognition of, dietary management. © 2013 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  19. The costs in provision of haemodialysis in a developing country: a multi-centered study.

    PubMed

    Ranasinghe, Priyanga; Perera, Yashasvi S; Makarim, Mohamed F M; Wijesinghe, Aruna; Wanigasuriya, Kamani

    2011-09-06

    Chronic Kidney Disease is a major public health problem worldwide with enormous cost burdens on health care systems in developing countries. We aimed to provide a detailed analysis of the processes and costs of haemodialysis in Sri Lanka and provide a framework for modeling similar financial audits. This prospective study was conducted at haemodialysis units of three public and two private hospitals in Sri Lanka for two months in June and July 2010. Cost of drugs and consumables for the three public hospitals were obtained from the price list issued by the Medical Supplies Division of the Department of Health Services, while for the two private hospitals they were obtained from financial departments of the respective hospitals. Staff wages were obtained from the hospital chief accountant/chief financial officers. The cost of electricity and water per month was calculated directly with the assistance of expert engineers. An apportion was done from the total hospital costs of administration, cleaning services, security, waste disposal and, laundry and sterilization for each unit. The total number of dialysis sessions (hours) at the five hospitals for June and July were 3341 (12959) and 3386 (13301) respectively. Drug and consumables costs accounted for 70.4-84.9% of the total costs, followed by the wages of the nursing staff at each unit (7.8-19.7%). The mean cost of a dialysis session in Sri Lanka was LKR 6,377 (US$ 56). The annual cost of haemodialysis for a patient with chronic renal failure undergoing 2-3 dialysis session of four hours duration per week was LKR 663,208-994,812 (US$ 5,869-8,804). At one hospital where facilities are available for the re-use of dialyzers (although not done during study period) the cost of consumables would have come down from LKR 5,940,705 to LKR 3,368,785 (43% reduction) if the method was adopted, reducing costs of haemodialysis per hour from LKR 1,327 at present to LKR 892 (33% reduction). This multi-centered study demonstrated

  20. Accelerated vascular calcification and relative hypoparathyroidism in incident haemodialysis diabetic patients receiving calcium binders.

    PubMed

    Galassi, Andrea; Spiegel, David M; Bellasi, Antonio; Block, Geoffrey A; Raggi, Paolo

    2006-11-01

    Vascular calcification and low bone turnover with a relatively low parathyroid hormone (PTH) often coexist in diabetic patients undergoing haemodialysis. Since calcium salts (CaS) are used extensively as primary phosphate binders and have been associated with progressive vascular calcification, we studied the effects of CaS on coronary arteries and parathyroid activity in incident haemodialysis diabetic patients. We measured the change in coronary artery calcium scores (CACS) with sequential electron beam computed tomography (EBCT) in 64 diabetic and 45 non-diabetic patients, randomized to CaS or sevelamer within 90 days of starting haemodialysis. CACS measurements were repeated after 6, 12 and 18 months. Serum intact PTH (iPTH), calcium and phosphorus were serially tested. During the study period, serum phosphate was similar in diabetic and non-diabetic patients. Serum calcium levels were similar at baseline (2.3+/-0.25 mmol/l for both) and increased significantly with CaS treatment (P<0.05) both in diabetic and non-diabetic patients but not with sevelamer. Diabetic patients treated with CaS showed a significantly greater CACS progression than sevelamer-treated patients (median increase 177 vs 27; P=0.05). During follow-up, diabetic patients receiving CaS were significantly more likely to develop serum iPTH values<16 pmol/l than diabetic patients treated with sevelamer (33% vs 6%, P=0.005) and had a lower mean iPTH level (24+/-16 vs 31+/-14 pmol/l; P=0.038). The management of hyperphosphataemia with CaS in haemodialysis diabetic patients is associated with a significantly greater progression of CACS than with sevelamer. These effects are accompanied by iPTH changes suggestive of low bone turnover.

  1. Medtronic Freestyle aortic bioprosthesis: a potential option for haemodialysis patients†.

    PubMed

    Hegazy, Yasser Y; Rayan, Amr; Sodian, Ralf; Hassanein, Wael; Ennker, Jürgen

    2016-04-01

    End-stage renal disease patients on regular haemodialysis are at higher risk of calcification. Therefore, many surgeons have concerns regarding the implantation of bioprostheses in such patients. The haemodynamic advantages of stentless aortic bioprostheses support their use; however, these have not been studied yet in end-stage renal disease patients. We studied accordingly the early and mid-term outcomes of aortic valve replacement (AVR) using Medtronic Freestyle stentless aortic bioprostheses in this subset of patients in comparison with stented aortic bioprostheses. We retrospectively studied two groups of consecutive patients on regular haemodialysis who required AVR between 2007 and 2013. Non-Freestyle (NFS) group received stented aortic bioprostheses (36 patients) and Freestyle (FS) group received Medtronic Freestyle aortic bioprostheses (48 patients). Follow-up ranged from 2 to 76 months with a mean follow-up of 36.3 ± 25 months. Patients in both groups showed similar demographic characters regarding age (76.4 ± 8.1 vs 74.9 ± 7.2 years; P = 0.35), male gender (58 vs 60%; P = 0.57) and diabetes mellitus (42 vs 48%; P = 0.57). Smaller aortic bioprostheses were implanted in the NFS (23.3 ± 1.2 vs 25.4 ± 2.1; P < 0.001) with consequently higher postoperative mean gradients (14.1 ± 4.1 vs 11.9 ± 5.3 mmHg; P = 0.004). No significant differences were noted regarding postoperative neurological disorder (8 vs 12%; P = 0.73), deep sternal wound infection (3 vs 4%; P = 0.68), re-exploration (8 vs 8%; P = 0.91) and in-hospital mortality (6 vs 4%; P = 0.92). Mid-term follow-up showed higher prosthetic valve calcification and/or sclerosis in NFS group (25 vs 6%; P = 0.015), whereas no significant differences were noticed between the two groups regarding stroke (0 vs 8%; P = 0.13), endocarditis (0 vs 4%; P = 0.50), 36- and 72-month survival (51 ± 2%, 14 ± 4% vs 55 ± 2%, 19 ± 3%, respectively; P = 0.45). Aortic bioprostheses are a good option for haemodialysis

  2. Ultrasonic Blood Flow Measurement in Haemodialysis

    PubMed Central

    Sampson, D.; Papadimitriou, M.; Kulatilake, A. E.

    1970-01-01

    A 5-megacycle Doppler flow meter, calibrated in-vitro, was found to give a linear response to blood flow in the ranges commonly encountered in haemodialysis. With this, blood flow through artificial kidneys could be measured simply and with a clinically acceptable error. The method is safe, as blood lines do not have to be punctured or disconnected and hence there is no risk of introducing infection. Besides its value as a research tool the flow meter is useful in evaluating new artificial kidneys. Suitably modified it could form the basis of an arterial flow alarm system. PMID:5416812

  3. Non-contrast-enhanced imaging of haemodialysis fistulas using quiescent-interval single-shot (QISS) MRA: a feasibility study.

    PubMed

    Okur, A; Kantarci, M; Karaca, L; Yildiz, S; Sade, R; Pirimoglu, B; Keles, M; Avci, A; Çankaya, E; Schmitt, P

    2016-03-01

    To assess the efficiency of a novel quiescent-interval single-shot (QISS) technique for non-contrast-enhanced magnetic resonance angiography (MRA) of haemodialysis fistulas. QISS MRA and colour Doppler ultrasound (CDU) images were obtained from 22 haemodialysis patients with end-stage renal disease (ESRD). A radiologist with extensive experience in vascular imaging initially assessed the fistulas using CDU. Two observers analysed each QISS MRA data set in terms of image quality, using a five-point scale ranging from 0 (non-diagnostic) to 4 (excellent), and lumen diameters of all segments were measured. One hundred vascular segments were analysed for QISS MRA. Two anastomosis segments were considered non-diagnostic. None of the arterial or venous segments were evaluated as non-diagnostic. The image quality was poorer for the anastomosis level compared to the other segments (p<0.001 for arterial segments, and p<0.05 for venous segments), while no significant difference was determined for other vascular segments. QISS MRA has the potential to provide valuable complementary information to CDU regarding the imaging of haemodialysis fistulas. In addition, QISS non-enhanced MRA represents an alternative for assessment of haemodialysis fistulas, in which the administration of iodinated or gadolinium-based contrast agents is contraindicated. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  4. Subgroups of haemodialysis patients in relation to fluid intake restrictions: a cluster analytical approach.

    PubMed

    Lindberg, Magnus; Wikström, Björn; Lindberg, Per

    2010-11-01

    To determine whether definable subgroups exist in a sample of haemodialysis patients with regard to self-efficacy, attentional style and depressive symptomatology and to compare whether interdialytic weight gain varies between patients in groups with different cognitive profiles. Theory-based research suggests that cognitive factors (e.g. self-efficacy and attentional style) and depressive symptomatology undermine adherence to health protective regimens. Preventing negative outcomes of fluid overload is essential for haemodialysis patients but many patients cannot achieve fluid control, and nursing interventions aimed to help the patients reduce fluid intake are ineffective. Understanding the interaction between cognitive factors and how this is related to adherence outcomes might therefore lead to the development of helpful nursing interventions. Explorative cross-sectional multicentre survey. The sample consisted of 133 haemodialysis patients. Data were collected using structured questionnaires. A brief self-report form and data on interdialytic weight gain was also used. Two-step cluster analysis was used to identify subgroups. One-way analysis of variance (anova) or Pearson's chi-square test was used for comparing subgroups. Three distinct subgroups were found and subsequently labelled: (1) low self-efficacy, (2) distraction and depressive symptoms and (3) high self-efficacy. The subgroups differed in fluid intake, but not in age, dialysis vintage, gender, residual urine output or in receiving any fluid intake advice. Clinically relevant subgroups of haemodialysis patients could be defined by their profiles regarding self-efficacy, attentional style and depressive symptoms. Based on this study, we would encourage clinical practitioners to take into account cognitive profiles while performing their work. This is especially important when a targeted nursing intervention, which aims to encourage and maintain the patient's fluid control, is introduced. © 2010

  5. A user-friendly tool for incremental haemodialysis prescription.

    PubMed

    Casino, Francesco Gaetano; Basile, Carlo

    2018-01-05

    There is a recently heightened interest in incremental haemodialysis (IHD), the main advantage of which could likely be a better preservation of the residual kidney function of the patients. The implementation of IHD, however, is hindered by many factors, among them, the mathematical complexity of its prescription. The aim of our study was to design a user-friendly tool for IHD prescription, consisting of only a few rows of a common spreadsheet. The keystone of our spreadsheet was the following fundamental concept: the dialysis dose to be prescribed in IHD depends only on the normalized urea clearance provided by the native kidneys (KRUn) of the patient for each frequency of treatment, according to the variable target model recently proposed by Casino and Basile (The variable target model: a paradigm shift in the incremental haemodialysis prescription. Nephrol Dial Transplant 2017; 32: 182-190). The first step was to put in sequence a series of equations in order to calculate, firstly, KRUn and, then, the key parameters to be prescribed for an adequate IHD; the second step was to compare KRUn values obtained with our spreadsheet with KRUn values obtainable with the gold standard Solute-solver (Daugirdas JT et al., Solute-solver: a web-based tool for modeling urea kinetics for a broad range of hemodialysis schedules in multiple patients. Am J Kidney Dis 2009; 54: 798-809) in a sample of 40 incident haemodialysis patients. Our spreadsheet provided excellent results. The differences with Solute-solver were clinically negligible. This was confirmed by the Bland-Altman plot built to analyse the agreement between KRUn values obtained with the two methods: the difference was 0.07 ± 0.05 mL/min/35 L. Our spreadsheet is a user-friendly tool able to provide clinically acceptable results in IHD prescription. Two immediate consequences could derive: (i) a larger dissemination of IHD might occur; and (ii) our spreadsheet could represent a useful tool for an ineludibly

  6. Patterns of use and appropriateness of antibiotics prescribed to patients receiving haemodialysis: an observational study.

    PubMed

    Hui, Katrina; Nalder, Michelle; Buising, Kirsty; Pefanis, Aspasia; Ooi, Khai Y; Pedagogos, Eugenie; Nelson, Craig; Kirkpatrick, Carl M J; Kong, David C M

    2017-05-12

    There are limited published data on the types and appropriateness of oral and intravenous (IV) antibiotics prescribed to patients receiving haemodialysis. This information is critical to optimise antibiotic prescribing. Therefore this study aims to describe the patterns of use and the appropriateness of oral and IV antibiotics prescribed to patients receiving haemodialysis. This was a prospective, observational study across four community and two hospital inpatient haemodialysis units in Melbourne, Australia. Data were collected from July 2014 to January 2015 from participants. Antibiotic regimens prescribed were compared with nationally available antibiotic guidelines and then classified as being either appropriate, inappropriate or not assessable by an expert multidisciplinary team using the National Antimicrobial Prescribing Survey tool. Overall, 114 participants consented to this study where 55.3% (63/114) received antibiotics and 235 antibiotic regimens were prescribed at a rate of 69.1 antibiotic regimens/100 patient-months. The most common oral antibiotics prescribed were amoxycillin/clavulanic acid and cephalexin. The most common IV antibiotics prescribed were vancomycin, piperacillin/tazobactam, cephazolin and ceftriaxone. The percentage of inappropriate antibiotic regimens prescribed were 34.9% (15/43) in the community setting and 22.1% (40/181) in the hospital setting. Furthermore, 29.4% (30/102) of oral and 20.5% (25/122) of IV antibiotic regimens were inappropriate with incorrect dosing as the primary reason. Although this study is limited by the sample size, it describes the high antibiotic exposure that patients receiving haemodialysis experience. Of concern is inappropriate dose and frequency being a major issue. This requires interventions focused on the quality use of medicines and antimicrobial stewardship aspects of prescribing in this population.

  7. The costs in provision of haemodialysis in a developing country: A multi-centered study

    PubMed Central

    2011-01-01

    Background Chronic Kidney Disease is a major public health problem worldwide with enormous cost burdens on health care systems in developing countries. We aimed to provide a detailed analysis of the processes and costs of haemodialysis in Sri Lanka and provide a framework for modeling similar financial audits. Methods This prospective study was conducted at haemodialysis units of three public and two private hospitals in Sri Lanka for two months in June and July 2010. Cost of drugs and consumables for the three public hospitals were obtained from the price list issued by the Medical Supplies Division of the Department of Health Services, while for the two private hospitals they were obtained from financial departments of the respective hospitals. Staff wages were obtained from the hospital chief accountant/chief financial officers. The cost of electricity and water per month was calculated directly with the assistance of expert engineers. An apportion was done from the total hospital costs of administration, cleaning services, security, waste disposal and, laundry and sterilization for each unit. Results The total number of dialysis sessions (hours) at the five hospitals for June and July were 3341 (12959) and 3386 (13301) respectively. Drug and consumables costs accounted for 70.4-84.9% of the total costs, followed by the wages of the nursing staff at each unit (7.8-19.7%). The mean cost of a dialysis session in Sri Lanka was LKR 6,377 (US$ 56). The annual cost of haemodialysis for a patient with chronic renal failure undergoing 2-3 dialysis session of four hours duration per week was LKR 663,208-994,812 (US$ 5,869-8,804). At one hospital where facilities are available for the re-use of dialyzers (although not done during study period) the cost of consumables would have come down from LKR 5,940,705 to LKR 3,368,785 (43% reduction) if the method was adopted, reducing costs of haemodialysis per hour from LKR 1,327 at present to LKR 892 (33% reduction). Conclusions

  8. Relationships between iron dose, hospitalizations and mortality in incident haemodialysis patients: a propensity-score matched approach.

    PubMed

    Varas, Javier; Ramos, Rosa; Aljama, Pedro; Pérez-García, Rafael; Moreso, Francesc; Pinedo, Miguel; Ignacio Merello, José; Stuard, Stefano; Canaud, Bernard; Martín-Malo, Alejandro

    2018-01-01

    Intravenous iron management is common in the haemodialysis population. However, the safest dosing strategy remains uncertain, in terms of the risk of hospitalization and mortality. We aimed to determine the effects of cumulative monthly iron doses on mortality and hospitalization. This multicentre observational retrospective propensity-matched score study included 1679 incident haemodialysis patients. We measured baseline demographic variables, haemodialysis clinical parameters and laboratory analytical values. We compared outcomes among quartiles of cumulative iron dose (mg/kg/month). We implemented propensity-score matching (PSM) to reduce confounding due to indication. In the PSM cohort (330 patients), we compared outcomes between groups that received cumulative iron doses above and below 5.66 mg/kg/month. Kaplan-Meier analyses showed that the high iron dose group had significantly worse survival than the low iron dose group. A univariate analysis indicated that the monthly iron dose could significantly predict mortality. However, a multivariate regression did not confirm that finding. The multivariate regression analysis revealed that iron doses  >5.58 mg/kg/month were not associated with elevated mortality risk, but they were associated with elevated risks of all-cause and cardiovascular-related hospitalizations. These results were ratified in the PSM population. Intravenous iron administration is advisable for maintaining haemoglobin levels in patients that receive haemodialysis. Our data suggested that large monthly iron doses, adjusted for body weight, were associated with more hospitalizations, but not with mortality or infection-related hospitalizations. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  9. Spanish Clinical Guidelines on Vascular Access for Haemodialysis.

    PubMed

    Ibeas, José; Roca-Tey, Ramon; Vallespín, Joaquín; Moreno, Teresa; Moñux, Guillermo; Martí-Monrós, Anna; Del Pozo, José Luis; Gruss, Enrique; Ramírez de Arellano, Manel; Fontseré, Néstor; Arenas, María Dolores; Merino, José Luis; García-Revillo, José; Caro, Pilar; López-Espada, Cristina; Giménez-Gaibar, Antonio; Fernández-Lucas, Milagros; Valdés, Pablo; Fernández-Quesada, Fidel; de la Fuente, Natalia; Hernán, David; Arribas, Patricia; Sánchez de la Nieta, María Dolores; Martínez, María Teresa; Barba, Ángel

    2017-11-01

    Vascular access for haemodialysis is key in renal patients both due to its associated morbidity and mortality and due to its impact on quality of life. The process, from the creation and maintenance of vascular access to the treatment of its complications, represents a challenge when it comes to decision-making, due to the complexity of the existing disease and the diversity of the specialities involved. With a view to finding a common approach, the Spanish Multidisciplinary Group on Vascular Access (GEMAV), which includes experts from the five scientific societies involved (nephrology [S.E.N.], vascular surgery [SEACV], vascular and interventional radiology [SERAM-SERVEI], infectious diseases [SEIMC] and nephrology nursing [SEDEN]), along with the methodological support of the Cochrane Center, has updated the Guidelines on Vascular Access for Haemodialysis, published in 2005. These guidelines maintain a similar structure, in that they review the evidence without compromising the educational aspects. However, on one hand, they provide an update to methodology development following the guidelines of the GRADE system in order to translate this systematic review of evidence into recommendations that facilitate decision-making in routine clinical practice, and, on the other hand, the guidelines establish quality indicators which make it possible to monitor the quality of healthcare. Copyright © 2017 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  10. Treatment of a Patient with Psychotic Disorder Undergoing Haemodialysis: a Case Report.

    PubMed

    Turčin, Arijana

    2018-06-01

    We report a case of a 35-year old male patient that was in treatment for chronic kidney failure for 20 years, with a personal history of unsuccessful kidney transplantation and undergoing continuous haemodialysis. He had to be treated psychiatrically for the first time because of exacerbation of psychotic symptoms. He was hospitalized twice in succession, because of the severity of the psychotic symptoms that included imperative auditory hallucinations that also led to a serious suicidal attempt. The prescribed psychiatric therapy had to be adjusted in type, dosage and especially the time of administration as his psychiatric status fluctuated every two days in sync with the wash-out of medication due to haemodialysis. The choice of adequate psychotropic medication in a haemodialysed patient is limited and the regime of the drug administration is also very important for the success of treatment and achieving remission.

  11. Patients' adherence to aspects of haemodialysis regimens in tropical north Queensland, Australia.

    PubMed

    Smyth, Wendy; Hartig, Vicki; Hayes, Megan; Manickam, Valli

    2015-06-01

    Patients with end-stage kidney disease often have difficulty in adhering to aspects of their haemodialysis regimens. This study aimed to quantify the number of patients who attended 100% of their scheduled haemodialysis sessions, and the number of patients who gained no more than one kilogram per day between dialysis sessions, over a three-month period. Retrospective chart audit Patients undergoing haemodialysis at an in-hospital centre in tropical Australia. A renal nurse audited the 72 charts pertaining to a 12-week period in 2013. Patients attended 90.1% of all scheduled dialysis sessions. Forty-one patients attended all sessions, with the remaining 31 missing at least one scheduled session. One patient missed 16 scheduled sessions. The following were statistically less likely to attend all their scheduled sessions: Aboriginal and Torres Strait Islander patients; patients on a three times per week dialysis schedule; patients who had relocated from rural or regional towns and younger patients. The average daily weight gain ranged from 0.414 kg to 1.017 kg (mean = 0.885 kg). Younger patients were statistically less likely to adhere to fluid restrictions; patients without diabetes were more likely to adhere to the fluid allowances. Renal services need to assist patients to adhere to their regimens. Initially, this service will examine strategies to maximise the likelihood of patients attending all of their dialysis sessions. Such an outcome will help to delay deterioration in the patients' health status, while minimising additional strain on the health service. © 2015 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  12. A care study exploring a patient's non-compliance to haemodialysis.

    PubMed

    Murphy, Fiona

    This care study is based on the nursing assessment of a 26-year-old man (MT) who attends a local haemodialysis unit for treatment using Gordon's (1994) functional health patterns. There will be a discussion of this framework and the methods used to assess this patient including an exploration of one of the problem areas identified--that of non-compliance.

  13. The effects of aromatherapy with lavender essential oil on fatigue levels in haemodialysis patients: A randomized clinical trial.

    PubMed

    Bagheri-Nesami, Masoumeh; Shorofi, Seyed Afshin; Nikkhah, Attieh; Espahbodi, Fatemeh; Ghaderi Koolaee, Fahimeh-Sadat

    2016-02-01

    This study was intended to examine the efficacy of lavender essential oil for the alleviation of fatigue in haemodialysis patients. This randomized clinical trial was conducted on 59 haemodialysis patients in two groups. The routine care group received the routine care, but the experimental group inhaled lavender essence 5% for 10 min, three times a week for 4 consecutive weeks. The Fatigue Severity Scale was used to assess fatigue before the intervention and after the last intervention in the second and fourth weeks. No statistically significant differences were observed between the two groups in terms of the fatigue scores before, and after the last intervention in the second and fourth weeks. Our result does not support other studies suggesting that lavender essential oil is effective on fatigue in haemodialysis patients. This conflicting result can mostly be ascribed to a variety of factors such as duration of aromatherapy and differences in concentrations of lavender essential oil. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Peritoneal dialysis vs. haemodialysis in the management of paediatric acute kidney injury in Kano, Nigeria: a cost analysis.

    PubMed

    Obiagwu, Patience N; Abdu, Aliyu

    2015-01-01

    To determine the cost of the dialytic management of paediatric acute kidney injury in a low-income country. All children under the age of 15 years, who had either peritoneal dialysis or haemodialysis for acute kidney injury in Aminu Kano Teaching Hospital over a 1-year period, were studied. The average cost of each dialysis modality was estimated. Of 20 children, who had dialysis for acute kidney injury, 12 (60%) had haemodialysis and 8 (40%) had peritoneal dialysis. The mean cost for haemodialysis exceeded that of peritoneal dialysis ($363.33 vs. $311.66, t = 1.04, P = 0.313) with the mean cost of consumables significantly accounting for most of the cost variation ($248.49 vs. $164.73, t = 2.91, P = 0.009). Mean costs of nephrologist visit and nursing were not found to be significant. Peritoneal dialysis is the less costly alternative for managing acute kidney injury in children in our environment. © 2014 John Wiley & Sons Ltd.

  15. The effects of intermittent fasting during the month of Ramadan in chronic haemodialysis patients in a tropical climate country.

    PubMed

    Wan Md Adnan, Wan Ahmad Hafiz; Zaharan, Nur Lisa; Wong, Mun Hoe; Lim, Soo Kun

    2014-01-01

    Chronic kidney disease is an emerging problem in the majority Muslim countries. Despite the uncertainties of the risks involved, some Muslim patients undergoing chronic haemodialysis choose to observe intermittent fasting during the month of Ramadan. This study aims to investigate the effect of Ramadan fasting in haemodialysis patients residing in a tropical climate country. This prospective cross sectional study recruited Muslim patients on regular haemodialysis from three haemodialysis centres in Kuala Lumpur from 15th July 2011 to 29th August 2011. Patients who fasted for any number of days were included (n = 35, 54% female, age 54±11 years). 89% of patients fasted for more than 15 days and 49% were diabetics. Dialysis parameters and blood samples were obtained one week prior to Ramadan and during the last week of Ramadan. The differences in dialysis parameters and biochemical values pre- and end-Ramadan were examined using paired t-test. Both pre- and post-dialysis weight were significantly decreased during Ramadan fasting compared to the month prior (p = <0.001). There was a significant decrease in the amount of ultrafiltration (p = 0.002). There were no significant differences in dry weight, inter-dialytic weight gain, mean urea reduction ratio or blood pressure measurements comparing pre- and end of Ramadan fasting. There was a significant increase in serum albumin level (p = 0.006) and decrease in serum phosphate level (p = 0.02) at the end of Ramadan. Ramadan fasting is associated with reduced weight, improved serum albumin and phosphate level in our population of haemodialysis patients. A larger multi-centre study will allow us to understand more about the effects of fasting in this population.

  16. The Effects of Intermittent Fasting during the Month of Ramadan in Chronic Haemodialysis Patients in a Tropical Climate Country

    PubMed Central

    Wan Md Adnan, Wan Ahmad Hafiz; Zaharan, Nur Lisa; Wong, Mun Hoe; Lim, Soo Kun

    2014-01-01

    Background Chronic kidney disease is an emerging problem in the majority Muslim countries. Despite the uncertainties of the risks involved, some Muslim patients undergoing chronic haemodialysis choose to observe intermittent fasting during the month of Ramadan. This study aims to investigate the effect of Ramadan fasting in haemodialysis patients residing in a tropical climate country. Methods This prospective cross sectional study recruited Muslim patients on regular haemodialysis from three haemodialysis centres in Kuala Lumpur from 15th July 2011 to 29th August 2011. Patients who fasted for any number of days were included (n = 35, 54% female, age 54±11 years). 89% of patients fasted for more than 15 days and 49% were diabetics. Dialysis parameters and blood samples were obtained one week prior to Ramadan and during the last week of Ramadan. The differences in dialysis parameters and biochemical values pre- and end-Ramadan were examined using paired t-test. Results Both pre- and post-dialysis weight were significantly decreased during Ramadan fasting compared to the month prior (p = <0.001). There was a significant decrease in the amount of ultrafiltration (p = 0.002). There were no significant differences in dry weight, inter-dialytic weight gain, mean urea reduction ratio or blood pressure measurements comparing pre- and end of Ramadan fasting. There was a significant increase in serum albumin level (p = 0.006) and decrease in serum phosphate level (p = 0.02) at the end of Ramadan. Conclusion Ramadan fasting is associated with reduced weight, improved serum albumin and phosphate level in our population of haemodialysis patients. A larger multi-centre study will allow us to understand more about the effects of fasting in this population. PMID:25546434

  17. Preliminary study of an exercise programme for reducing fatigue and improving sleep among long-term haemodialysis patients.

    PubMed

    Maniam, Radha; Subramanian, Pathmawathi; Singh, Surindar Kaur Surat; Lim, Soo Kun; Chinna, Karuthan; Rosli, Roshaslina

    2014-09-01

    Fatigue and quality of sleep are the main factors that contribute to a poor quality of life among patients on long-term haemodialysis. Studies have also emphasised the importance of exercise for improving the wellbeing of dialysis patients. This study aimed to determine the effectiveness of a predialysis low-to-moderate-intensity exercise programme for reducing fatigue and improving sleep disorders among long-term haemodialysis patients. In this quasi-experimental study, an exercise programme was conducted three times a week for 12 weeks before long-term haemodialysis patients underwent dialysis at two centres. The patients were categorised into either the exercise group (n = 28) or control group (n = 27). The latter was asked to maintain their current lifestyles. Assessments of fatigue and sleep disorder levels were performed for both groups using self-reported questionnaires at baseline and after intervention. The patients' perception of the exercise programme was also determined using self-reported questionnaires. Paired sample t-test indicated improvements in fatigue level in the exercise group (mean fatigue score: post-treatment 40.5 ± 7.9 vs. pre-treatment 30.0 ± 10.9). Improvements in sleep disorders were also observed in the exercise group (mean score: post-treatment 7.6 ± 3.3 vs. pre-treatment 10.1 ± 3.8). However, sleep quality deteriorated in the control group (mean score: post-treatment 10.7 ± 2.9 vs. pre-treatment 9.3 ± 2.9). Simple low-to-moderate-intensity exercise is effective for improving fatigue, sleep disorders and the overall quality of life among haemodialysis patients.

  18. Perspectives of healthcare providers on the nutritional management of patients on haemodialysis in Australia: an interview study

    PubMed Central

    Tong, Allison; Campbell, Katrina L; Craig, Jonathan C; Lee, Vincent W

    2018-01-01

    Objective To describe the perspectives of healthcare providers on the nutritional management of patients on haemodialysis, which may inform strategies for improving patient-centred nutritional care. Design Face-to-face semistructured interviews were conducted until data saturation, and thematic analysis based on principles of grounded theory. Setting 21 haemodialysis centres across Australia. Participants 42 haemodialysis clinicians (nephrologists and nephrology trainees (15), nurses (12) and dietitians (15)) were purposively sampled to obtain a range of demographic characteristics and clinical experiences. Results Six themes were identified: responding to changing clinical status (individualising strategies to patient needs, prioritising acute events, adapting guidelines), integrating patient circumstances (assimilating life priorities, access and affordability), delineating specialty roles in collaborative structures (shared and cohesive care, pivotal role of dietary expertise, facilitating access to nutritional care, perpetuating conflicting advice and patient confusion, devaluing nutritional specialty), empowerment for behaviour change (enabling comprehension of complexities, building autonomy and ownership, developing self-efficacy through engagement, tailoring self-management strategies), initiating and sustaining motivation (encountering motivational hurdles, empathy for confronting life changes, fostering non-judgemental relationships, emphasising symptomatic and tangible benefits, harnessing support networks), and organisational and staffing barriers (staffing shortfalls, readdressing system inefficiencies). Conclusions Organisational support with collaborative multidisciplinary teams and individualised patient care were seen as necessary for developing positive patient–clinician relationships, delivering consistent nutrition advice, and building and sustaining patient motivation to enable change in dietary behaviour. Improving service delivery and

  19. Associations of marital status with mortality from all causes and mortality from cardiovascular disease in Japanese haemodialysis patients.

    PubMed

    Tanno, Kozo; Ohsawa, Masaki; Itai, Kazuyoshi; Kato, Karen; Turin, Tanvir Chowdhury; Onoda, Toshiyuki; Sakata, Kiyomi; Okayama, Akira; Fujioka, Tomoaki

    2013-04-01

    Marital status is an important social factor associated with increased mortality from cardiovascular disease (CVD) and all causes. However, there has been no study on the association of marital status with mortality in haemodialysis patients. We analysed data from a 5-year prospective cohort study of 1064 Japanese haemodialysis patients aged 30 years or older. Marital status was classified into three groups: married, single and divorced/widowed. Cox's regression was used to estimate multivariate hazard ratios (HRs) [95% confidence intervals (CIs)] for all-cause mortality and CVD mortality according to marital status after adjusting for age, sex, duration of haemodialysis, cause of renal failure, body mass index, systolic blood pressure, total cholesterol, high density lipoprotein-cholesterol, albumin, high-sensitivity C-reactive protein, co-morbid conditions, smoking, alcohol consumption, education levels and job status. Single patients had higher risks than married patients for mortality from all causes (HR = 1.51, 95% CI: 1.06-2.16) and mortality from CVD (HR = 1.68, 95% CI: 1.03-2.76), and divorced/widowed patients had a higher risk than married patients for mortality from CVD (HR = 1.73, 95% CI: 1.15-2.60). After stratification by age, single patients aged 30-59 years had significantly higher risks for all-cause mortality and CVD mortality. The findings suggest that single status is a significant predictor for all-cause mortality and CVD mortality and that divorced/widowed status is a significant predictor for CVD mortality in haemodialysis patients.

  20. Body mass index trend in haemodialysis patients: the shift of nutritional disorders in two Italian regions.

    PubMed

    Postorino, Maurizio; Mancini, Elena; D'Arrigo, Graziella; Marino, Carmela; Vilasi, Antonio; Tripepi, Giovanni; Gallus, Silvano; Lugo, Alessandra; Santoro, Antonio; Zoccali, Carmine

    2016-10-01

    In the USA, the increase in the prevalence of obesity in the general population has been accompanied by a marked increase in the prevalence and incidence of obesity in the dialysis population. However, secular trends of body mass index (BMI) have not been investigated in European renal registries. We investigated the secular trend of BMI across 18 years (1994-2011) in two haemodialysis (HD) registries (Calabria in southern Italy and Emilia in northern Italy) on a total of 16 201 prevalent HD patients and in a series of 3559 incident HD patients. We compared trends in BMI for HD patients with those in the background general population of the same regions. The average BMI rose from 23.5 kg/m(2) in 1994 to 25.5 (+8.5%) in 2011 in the Calabria registry and from 23.7 in 1998 to 25.4 (+7.1%) in 2011 in the Emilia registry (P < 0.001). The proportion of obese patients (i.e. with BMI >30 kg/m(2)) rose from 6 to 14% in Calabria and from 6 to 16% in Emilia (P < 0.001). These patterns were fully confirmed in incident patients and were mirrored by a substantial decline in the prevalence of underweight-normal and underweight (P < 0.001) patients. Of note, the steepness of the increase in BMI in haemodialysis patients was 3.7 times more pronounced than that in the coeval, age- and sex-matched general population of Calabria and Emilia. In two regional haemodialysis registries in Italy a steady increase in overweight and obese patients is observed. These patterns are more pronounced than those found in the general population. If further confirmed in other European haemodialysis cohorts, these findings may have relevant public health implications. © The Author 2016. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  1. Preliminary study of an exercise programme for reducing fatigue and improving sleep among long-term haemodialysis patients

    PubMed Central

    Maniam, Radha; Subramanian, Pathmawathi; Singh, Surindar Kaur Surat; Lim, Soo Kun; Chinna, Karuthan; Rosli, Roshaslina

    2014-01-01

    INTRODUCTION Fatigue and quality of sleep are the main factors that contribute to a poor quality of life among patients on long-term haemodialysis. Studies have also emphasised the importance of exercise for improving the wellbeing of dialysis patients. This study aimed to determine the effectiveness of a predialysis low-to-moderate-intensity exercise programme for reducing fatigue and improving sleep disorders among long-term haemodialysis patients. METHODS In this quasi-experimental study, an exercise programme was conducted three times a week for 12 weeks before long-term haemodialysis patients underwent dialysis at two centres. The patients were categorised into either the exercise group (n = 28) or control group (n = 27). The latter was asked to maintain their current lifestyles. Assessments of fatigue and sleep disorder levels were performed for both groups using self-reported questionnaires at baseline and after intervention. The patients’ perception of the exercise programme was also determined using self-reported questionnaires. RESULTS Paired sample t-test indicated improvements in fatigue level in the exercise group (mean fatigue score: post-treatment 40.5 ± 7.9 vs. pre-treatment 30.0 ± 10.9). Improvements in sleep disorders were also observed in the exercise group (mean score: post-treatment 7.6 ± 3.3 vs. pre-treatment 10.1 ± 3.8). However, sleep quality deteriorated in the control group (mean score: post-treatment 10.7 ± 2.9 vs. pre-treatment 9.3 ± 2.9). CONCLUSION Simple low-to-moderate-intensity exercise is effective for improving fatigue, sleep disorders and the overall quality of life among haemodialysis patients. PMID:25273932

  2. A Fuzzy-Based Decision Support Model for Selecting the Best Dialyser Flux in Haemodialysis.

    PubMed

    Oztürk, Necla; Tozan, Hakan

    2015-01-01

    Decision making is an important procedure for every organization. The procedure is particularly challenging for complicated multi-criteria problems. Selection of dialyser flux is one of the decisions routinely made for haemodialysis treatment provided for chronic kidney failure patients. This study provides a decision support model for selecting the best dialyser flux between high-flux and low-flux dialyser alternatives. The preferences of decision makers were collected via a questionnaire. A total of 45 questionnaires filled by dialysis physicians and nephrologists were assessed. A hybrid fuzzy-based decision support software that enables the use of Analytic Hierarchy Process (AHP), Fuzzy Analytic Hierarchy Process (FAHP), Analytic Network Process (ANP), and Fuzzy Analytic Network Process (FANP) was used to evaluate the flux selection model. In conclusion, the results showed that a high-flux dialyser is the best. option for haemodialysis treatment.

  3. The effects of a simulated laughter programme on mood, cortisol levels, and health-related quality of life among haemodialysis patients.

    PubMed

    Heo, Eun Hwa; Kim, Sehyun; Park, Hye-Ja; Kil, Suk Yong

    2016-11-01

    This study aimed to evaluate the effects of a simulated laughter programme on mood, cortisol levels, and health-related quality of life among haemodialysis patients. Forty participants were randomly assigned to a laughter group (n = 20) or a control group (n = 20). Eleven participants completed the laughter programme after haemodialysis sessions and 18 control participants remained. The 4-week simulated laughter programme included weekly 60 min group sessions of simulated laughter, breathing, stretching exercises, and meditation, as well as daily 15 s individual laughter sessions administered via telephone. Mood, cortisol levels, and health-related quality of life were analysed using the rank analysis of covariance, and Wilcoxon's signed rank test. The laughter group exhibited improvements in mood, symptoms, social interaction quality, and role limitations due to physical health. The simulated laughter programme may help improve mood and health-related quality of life among haemodialysis patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Hemothorax as a complication of subclavian vein cannulation with haemodialysis catheter - case report.

    PubMed

    Iwańczuk, Waldemar; Guźniczak, Piotr; Kasperczak, Jarosław

    2013-01-01

    We present the case of a 39 year-old male patient admitted to ICU with symptoms of acute metabolic acidosis. He was investigated for the presence of methanol and glycol. Conservative treatment was initially started, followed by haemodialysis. During insertion of a temporary haemodialysis catheter in a location of Haapaniemi and Slatis, the patient was conscious but restless; therefore sedation was required to continue the procedure. After three hours of haemodialysis, the patient's general condition suddenly deteriorated. Hypovolemic shock and acute respiratory distress led to hypothesis of right haemothorax, which was rapidly confirmed by angio-CT examination. Trachea was intubated, drainage of right pleura was performed and aggressive fluid treatment begun. The patient was admitted to the operating theatre, and thoracotomy with reconstruction of damaged right venous angle was carried out. After the operation, the patient was transferred to ICU. He was mechanically ventilated and remained haemodynamically unstable. Although fluids and blood-made concentrates were transfused and catecholamines continuously administered, his clinical condition deteriorated and finally the patient died. We found two independent causes of this fatality: hypovolemic shock and acute extrinsic metabolic acidosis. However, this paper focuses on the problem of the iatrogenic complication, which was haemothorax. In the literature there are described examples of such cases. Authors emphasise the most traumatic moment of cannulation as being insertion of the guidewire and dilator to perform a tunnel for the catheter. Puncture by needle and localisation of the central vein results in fewer complications. Furthermore, we strongly recommend monitoring patients after central veins cannulation. All sudden deteriorations in clinical condition should be followed by meticulous diagnosis for the presence of this life-threatening complication.

  5. Barriers to successful implementation of care in home haemodialysis (BASIC-HHD):1. Study design, methods and rationale.

    PubMed

    Jayanti, Anuradha; Wearden, Alison J; Morris, Julie; Brenchley, Paul; Abma, Inger; Bayer, Steffen; Barlow, James; Mitra, Sandip

    2013-09-17

    Ten years on from the National Institute of Health and Clinical Excellence' technology appraisal guideline on haemodialysis in 2002; the clinical community is yet to rise to the challenge of providing home haemodialysis (HHD) to 10-15% of the dialysis cohort. The renal registry report, suggests underutilization of a treatment type that has had a lot of research interest and several publications worldwide on its apparent benefit for both physical and mental health of patients. An understanding of the drivers to introducing and sustaining the modality, from organizational, economic, clinical and patient perspectives is fundamental to realizing the full benefits of the therapy with the potential to provide evidence base for effective care models. Through the BASIC-HHD study, we seek to understand the clinical, patient and carer related psychosocial, economic and organisational determinants of successful uptake and maintenance of home haemodialysis and thereby, engage all major stakeholders in the process. We have adopted an integrated mixed methodology (convergent, parallel design) for this study. The study arms include a. patient; b. organization; c. carer and d. economic evaluation. The three patient study cohorts (n = 500) include pre-dialysis patients (200), hospital haemodialysis (200) and home haemodialysis patients (100) from geographically distinct NHS sites, across the country and with variable prevalence of home haemodialysis. The pre-dialysis patients will also be prospectively followed up for a period of 12 months from study entry to understand their journey to renal replacement therapy and subsequently, before and after studies will be carried out for a select few who do commence dialysis in the study period. The process will entail quantitative methods and ethnographic interviews of all groups in the study. Data collection will involve clinical and biomarkers, psychosocial quantitative assessments and neuropsychometric tests in patients. Organizational

  6. Barriers to successful implementation of care in home haemodialysis (BASIC-HHD):1. Study design, methods and rationale

    PubMed Central

    2013-01-01

    Background Ten years on from the National Institute of Health and Clinical Excellence’ technology appraisal guideline on haemodialysis in 2002; the clinical community is yet to rise to the challenge of providing home haemodialysis (HHD) to 10-15% of the dialysis cohort. The renal registry report, suggests underutilization of a treatment type that has had a lot of research interest and several publications worldwide on its apparent benefit for both physical and mental health of patients. An understanding of the drivers to introducing and sustaining the modality, from organizational, economic, clinical and patient perspectives is fundamental to realizing the full benefits of the therapy with the potential to provide evidence base for effective care models. Through the BASIC-HHD study, we seek to understand the clinical, patient and carer related psychosocial, economic and organisational determinants of successful uptake and maintenance of home haemodialysis and thereby, engage all major stakeholders in the process. Design and methods We have adopted an integrated mixed methodology (convergent, parallel design) for this study. The study arms include a. patient; b. organization; c. carer and d. economic evaluation. The three patient study cohorts (n = 500) include pre-dialysis patients (200), hospital haemodialysis (200) and home haemodialysis patients (100) from geographically distinct NHS sites, across the country and with variable prevalence of home haemodialysis. The pre-dialysis patients will also be prospectively followed up for a period of 12 months from study entry to understand their journey to renal replacement therapy and subsequently, before and after studies will be carried out for a select few who do commence dialysis in the study period. The process will entail quantitative methods and ethnographic interviews of all groups in the study. Data collection will involve clinical and biomarkers, psychosocial quantitative assessments and neuropsychometric

  7. Reducing haemodialysis access infection rates.

    PubMed

    Dorman, Amanda; Dainton, Marissa

    Infections are the second most common cause of vascular access loss in the long-term haemodialysis patient, and recent years have seen an increase in healthcare-associated infections (HCAIs) associated with vascular access (Suhail, 2009). There have been a number of drivers including publication guidelines (Department of Health, 2006; 2007) and local protocols providing evidence-based recommendations that, when implemented, can reduce the risk of these infections. In England, the selection of bloodstream infections caused by methicillin resistant staphylococcus aureus (MRSA) as a significant clinical outcome has led to a vast amount of work in this area. Root cause analysis of individual infections (by the clinical teams when these occur) in many specialities identified areas where practice could be improved, including practice relating to vascular access within the renal setting. Manufacturers have also supported this work by focusing on developing products that are designed to reduce the likelihood of infections occurring. One product identified and used within the NHS is Chloraprep.

  8. Comparison of four different cardiac troponin assays in patients with end-stage renal disease on chronic haemodialysis.

    PubMed

    Helleskov Madsen, Lene; Ladefoged, Søren; Hildebrandt, Per; Atar, Dan

    2008-01-01

    Several studies have documented the importance of troponin elevation as a prognostic marker in end-stage renal disease (ESRD). The reason for the elevated concentrations is not clarified. We do not know whether the different assays recognize the same patients within ESRD populations. The aim of this study was to compare concentrations of troponin measured by four different assays in a cohort of patients with ESRD, to investigate whether haemodialysis affects troponin concentrations, and to compare the prognostic potential of the different assays. We included 109 patients on chronic haemodialysis. Serum cardiac troponin T (cTnT) was measured pre- and postdialysis using Elecsys 2010 and troponin I (cTnI) using Access AccuTnI, Dimension RxL and AIA-600II. The cTnT assay had the highest percentage of elevated concentrations for all chosen cut-offs with a reduction in percentage of patients with elevated concentrations during haemodialysis. Elecsys 2010 and AIA-600II demonstrated a significant increased mortality with raised concentrations of troponin. The diverging results in previous studies are most likely based on substantial differences in the analytical performance of the assays. The prognostic value of cTnT appears superior to cTnI, which amplifies the prognostic significance of this cardiovascular marker in patients with ESRD.

  9. Successful use of haemodialysis to treat phenobarbital overdose.

    PubMed

    Hoyland, Kimberley; Hoy, Michael; Austin, Richard; Wildman, Martyn

    2013-11-21

    A 50-year-old woman presented with coma caused by a phenobarbital overdose, requiring intubation and admission to critical care. She was an international visitor and had been prescribed the drug for night-sedation. Phenobarbital is a long-acting barbiturate, which in an overdose can cause central nervous system depression, respiratory failure and haemodynamic instability; these patients can remain obtunded for many days. After initial supportive therapy, she was dialysed to help in the elimination of the drug. Haemodialysis resulted in a markedly reduced plasma level of phenobarbital, which decreased the length of intubation and stay in the critical care unit and aided full recovery.

  10. Successful use of haemodialysis to treat phenobarbital overdose

    PubMed Central

    Hoyland, Kimberley; Hoy, Michael; Austin, Richard; Wildman, Martyn

    2013-01-01

    A 50-year-old woman presented with coma caused by a phenobarbital overdose, requiring intubation and admission to critical care. She was an international visitor and had been prescribed the drug for night-sedation. Phenobarbital is a long-acting barbiturate, which in an overdose can cause central nervous system depression, respiratory failure and haemodynamic instability; these patients can remain obtunded for many days. After initial supportive therapy, she was dialysed to help in the elimination of the drug. Haemodialysis resulted in a markedly reduced plasma level of phenobarbital, which decreased the length of intubation and stay in the critical care unit and aided full recovery. PMID:24265338

  11. An economic evaluation of intravenous versus oral iron supplementation in people on haemodialysis.

    PubMed

    Wong, Germaine; Howard, Kirsten; Hodson, Elisabeth; Irving, Michelle; Craig, Jonathan C

    2013-02-01

    Iron supplementation can be administered either intravenously or orally in patients with chronic kidney disease (CKD) and iron deficiency anaemia, but practice varies widely. The aim of this study was to estimate the health care costs and benefits of parenteral iron compared with oral iron in haemodialysis patients receiving erythropoiesis-stimulating agents (ESAs). Using broad health care funder perspective, a probabilistic Markov model was constructed to compare the cost-effectiveness and cost-utility of parenteral iron therapy versus oral iron for the management of haemodialysis patients with relative iron deficiency. A series of one-way, multi-way and probabilistic sensitivity analyses were conducted to assess the robustness of the model structure and the extent in which the model's assumptions were sensitive to the uncertainties within the input variables. Compared with oral iron, the incremental cost-effectiveness ratios (ICERs) for parenteral iron were $74,760 per life year saved and $34,660 per quality-adjusted life year (QALY) gained. A series of one-way sensitivity analyses show that the ICER is most sensitive to the probability of achieving haemoglobin (Hb) targets using supplemental iron with a consequential decrease in the standard ESA doses and the relative increased risk in all-cause mortality associated with low Hb levels (Hb < 9.0 g/dL). If the willingness-to-pay threshold was set at $50,000/QALY, the proportions of simulations that showed parenteral iron was cost-effective compared with oral iron were over 90%. Assuming that there is an overall increased mortality risk associated with very low Hb level (<9.0 g/dL), using parenteral iron to achieve an Hb target between 9.5 and 12 g/L is cost-effective compared with oral iron therapy among haemodialysis patients with relative iron deficiency.

  12. [A rare case of Graves' disease in a patient on regular haemodialysis].

    PubMed

    Boubaker, Karima; Ounissi, Mondher; Khiari, Karima; Harzallah, Amel; Abbes, Monia; El Younsi, Fethi; Ben Abdellah, Taieb; Ben Maïz, Hedi; Kaaroud, Hayet; Kheder, Adel

    2010-07-01

    Abnormal thyroid hormone production and metabolism are relatively common in chronic renal failure and in regular haemodialysis. Graves' disease is a very unusual condition and is difficult to identify. We report a case of Graves' disease in a patient on regular hemodialysis. A 26-year-old man undergoing regular hemodialysis from unknown chronic nephropathy since four years. The patient suffered from unexplained slimming and aggressiveness. On admission, he had an irritability, tremor of the extremities, arterial hypertension not controlled by the medical treatment, discrete asynergy oculo-palpebral, glare of the glance and protrusion of the ocular spheres. The thyroid was non palpable. Biological tests demonstrated hyperthyroidism. Thyroid-stimulating hormone receptor antibodies were positive. Thyroid echography and scintiscanning showed vascular and hyperfonctionnel character of the thyroid. The patient was treated radically by radioactive iodine 131 therapy after medical preparation by antithyroid agent. He developed hypothyroidism treated by substitutive treatment. The diagnosis of Graves' disease must be evoked even in the absence of specific symptoms in haemodialysis patients. In front of clinical symptoms, since the conventional treatment is effective and inoffensive. Copyright 2010 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.

  13. Comparison of haemodialysis patients and non-haemodialysis patients with respect to clinical characteristics and 3-year clinical outcomes after sirolimus-eluting stent implantation: insights from the Japan multi-centre post-marketing surveillance registry.

    PubMed

    Otsuka, Yoritaka; Ishiwata, Sugao; Inada, Tsukasa; Kanno, Hiroyuki; Kyo, Eisho; Hayashi, Yasuhiko; Fujita, Hiroshi; Michishita, Ichiro

    2011-04-01

    Long-term outcomes after sirolimus-eluting stent (SES) implantation in haemodialysis (HD) patients have remained controversial. We investigated the impact of HD on outcomes after SES implantation. We analysed the data on 2050 patients who underwent SES implantation in a multi-centre prospective registry in Japan. Three-year clinical outcomes were compared between the HD group (n = 106) and the non-haemodialysis (NH) group (n = 1944). At the 3-year clinical follow-up, the rates of unadjusted cardiac mortality (HD: 16.3 vs. NH: 2.3%) and target-lesion revascularization (TLR) (HD: 19.4 vs. NH: 6.6%) were significantly higher in the HD group than the NH group (P < 0.001). Although HD group had a numerically higher stent thrombosis rate, the difference in stent thrombosis between the two groups (HD: 2.0 vs. NH: 0.7%) did not reach statistical significance. Using Cox's proportional-hazard models with propensity score adjustment for baseline differences, the HD group had higher risks of TLR [HD: 16.3 vs. NH: 6.1%; hazard ratio, 2.83; 95% confidence interval (CI): 1.62-4.93, P = 0.0003] and cardiac death (HD: 12.3 vs. NH: 2.3%; hazard ratio, 5.51; 95% CI: 2.58-11.78, P < 0.0001). The consistent results of analyses, whether unadjusted or adjusted for other baseline clinical and procedural differences, identify HD as an independent risk factor for cardiac death and TLR. Percutaneous coronary intervention with SES in HD patients has a higher incidence of repeat revascularization and mortality compared with those in NH patients. Haemodialysis appears to be strongly associated with mortality and repeat revascularization even after SES implantation.

  14. Haemodialysis in an emerging centre in a developing country: a two year review and predictors of mortality

    PubMed Central

    2011-01-01

    Background Haemodialysis is the most common form of renal replacement therapy in Nigeria. The high cost of haemodialysis has made optimal therapy of end-stage renal disease difficult in Nigeria. This paper is a review of data collected over two years of provision of dialysis services in a new tertiary hospital in Southern Nigeria. Methods This retrospective analysis is done on data obtained from the patient case files and dialysis records in the first two years of provision of dialysis services in our centre. A gender comparison of the patients' baseline sociodemographic, clinical and biochemical was performed and a logistic regression model used to assess the predictors of mortality. Results A total of 98 patients had 471 sessions in the two years under review. Males and females had similar characteristics at baseline except for a higher median serum urea in the males. The commonest causes of end-stage renal disease were chronic glomerulonephritis (34.5%), hypertension (32.1%) and diabetes mellitus (17.9%). The main predictor of mortality was under treatment with haemodialysis due to inability to pay for more than a few dialysis sessions. Conclusions This study has highlighted the unchanging demographics of our advanced kidney failure patients. Efforts should be aimed at subsidizing the cost of dialysis for our teeming population of dialysis dependent chronic kidney disease patients. PMID:21962220

  15. Risk factors associated with xerostomia in haemodialysis patients

    PubMed Central

    López-Pintor, Lucía; Casañas, Elisabeth; de Arriba, Lorenzo; Hernández, Gonzalo

    2017-01-01

    Background To determine the prevalence of xerostomia and hyposalivation in Haemodialysis (HD) patients, to clarify risk factors, assess patient´s quality of life, and to establish a possible correlation among interdialytic weight gain (IDWG) and xerostomia. Material and Methods This study was performed on a group of 50 HD patients. Data were collected using a questionnaire containing demographic and clinical variables, a visual analogue scale (VAS) for xerostomia, IDWG, and an oral health impact profile questionnaire (OHIP-14). Unstimulated whole saliva (UWS) and stimulated whole saliva (SWS) were collected. Results A total of 28 HD patients (56%) suffered xerostomia. Dry mouth was associated with hypertension (OR, 5.24; 95% CI, 1.11-24.89) and benzodiazepine consumption (OR, 5.96; 95% CI, 1.05-33.99). The mean xerostomia VAS and OHIP-14 scores were 31.74±14.88 and 24.38±11.98, respectively. No significant correlation was observed between IDWG% and VAS and OHIP total score. Nonetheless, a positive correlation between VAS level of thirst and IDWG% was found (r=0.48 p=0.0001). UWS and SWS means (determined in 30 patients) were 0.16±0.17 and 1.12±0.64, respectively. Decreased values of UWS and SWS were reported in 53.33% and 36.66% of HD patients. Conclusions Xerostomia in HD has a multifactorial aetiology due to accumulative risks as advanced age, systemic disorders, drugs, fluid intake restriction, and salivary parenchymal fibrosis and atrophy. Therefore, it is important to detect possible xerostomia risk factors to treat correctly dry mouth in HD patients and avoid systemic complications. Key words:Haemodialysis patients, xerostomia, salivary flow rate, hyposalivation, interdialytic weight gain, oral health-related quality of life. PMID:28160594

  16. Preliminary report on the efficiency of combined haemodialysis-haemoperfusion treatment in chronic uraemia.

    PubMed

    Albertazzi, A; Cappelli, P; Di Paolo, B; Evangelista, M

    1984-01-01

    The use of activated charcoal haemoperfusion can play a complementary role in the substitutive treatment of chronic uraemia. This study reports the preliminary results of a regular combined haemodialysis-haemoperfusion treatment. The effectiveness of this treatment was observed on the subjective symptomatology (anorexia, nausea, asthenia) and on the polyneuropathy evaluated by electrophysiological assessments. The biocompatability of the system proved satisfactory.

  17. Evaluation of the effect of nurse education on patient-reported foot checks and foot care behaviour of people with diabetes receiving haemodialysis.

    PubMed

    Brand, S L; Musgrove, A; Jeffcoate, W J; Lincoln, N B

    2016-02-01

    To assess whether a programme of nurse education increased the frequency with which nurses conducted foot checks on people with diabetes undergoing haemodialysis and to evaluate whether this influenced self-reported foot care behaviour. A non-randomized stepped-wedge design was used to evaluate a nurse education programme implemented in four UK National Health Service dialysis units. People with diabetes undergoing haemodialysis were invited to complete a questionnaire on the frequency of foot examination by health professionals, on the presence of foot problems and on their own foot care behaviour, using the Nottingham Assessment of Functional Foot-care (NAFF). An education session for nurses, including procedures for foot examination, was conducted sequentially in each of four haemodialysis units. The questionnaire was repeated at 2-monthly intervals. The education session resulted in a significant increase in the reported number of foot examinations by nurses (P = 0.007). There was also a significant improvement in reported foot care behaviour (P < 0.001), but this occurred between the first and second 2-monthly assessments and was unrelated to the timing of the intervention. A single education session can improve the routine checking of the feet of people with diabetes undergoing haemodialysis. The administration of the Nottingham Assessment of Functional Foot-care questionnaire was associated with improved self-reported foot care behaviour, reflecting greater awareness of risk in this population. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.

  18. [Recurrent vascular access trombosis associated with the prothrombin mutation G20210A in a adult patient in haemodialysis].

    PubMed

    Quintana, L F; Coll, E; Monteagudo, I; Collado, S; López-Pedret, J; Cases, A

    2005-01-01

    Vascular access-related complications are a frequent cause of morbidity in haemodialysis patients and generate high costs. We present the case of an adult patient with end-stage renal disease and recurrent vascular access thrombosis associated with the prothrombin mutation G20210A and renal graft intolerance. The clinical expression of this heterozygous gene mutation may have been favoured by inflammatory state, frequent in dialysis patients. In this patient, the inflammatory response associated with the renal graft intolerance would have favored the development of recurrent vascular access thrombosis in a adult heterozygous for prothrombin mutation G20210A. In the case of early dysfunction of haemodialysis vascular access and after ruling out technical problems, it is convenient to carry out a screening for thrombophilia.

  19. Nutritional status of haemodialysis patients: comparison of Australian cohorts of Aboriginal and European descent.

    PubMed

    Todd, Alwyn; Carroll, Robert; Gallagher, Meghan; Meade, Anthony

    2013-12-01

    It is not known whether nutritional status differs between Australian Aboriginal and non Aboriginal haemodialysis subjects. The aim of this study was to investigate the nutritional status of Australian Aboriginal and non-Aboriginal haemodialysis subjects at satellite dialysis centres. Seventy-six (25 Aboriginal, 51 non-Aboriginal) prevalent haemodialysis patients were enrolled in a 3-month cross-sectional study. Each month anthropometric and biochemical measurements were collected. Nutritional status (diet history, patient-generated subjective global assessment (PG-SGA), handgrip strength) was assessed by a dietitian. PG-SGA detected mild to moderate malnutrition in 35% of Aboriginal patients and 25% of non-Aboriginal patients. The overall physical rating on the PG-SGA was significantly higher in Aboriginal patients, indicating the presence of a greater deficit in muscle mass in this population. Inter-dialytic weight gain was significantly greater in Aboriginal subjects (median [range] 3.0 [2.1-5.7] vs 2.5 [-0.3-5.0] kg, P<0.001). Glucose and HbA1c were significantly higher in Aboriginal subjects with diabetes than in non-Aboriginal patients with diabetes (median [range] 9.4 [4.9-23.4] vs 5.7 [3.1-12.9], P=0.002; 7.0 [5.2-11.0] vs 5.8 [4.6-9.0], P<0.000; respectively). These findings occurred in the setting of each cohort having adequate dialysis parameters (median Kt/V of >1.6 and median normalized protein catabolic rate 1.5). Difficulties were encountered in obtaining dietary information from Aboriginal subjects using the diet history method. Subjects had acceptable parameters of dialysis adequacy; however, 35% had evidence of malnutrition. Further research should focus on establishing a knowledge base for the nutritional management for Aboriginal dialysis subjects, and the development of a validated individual dietary assessment method for use in this population group. © 2013 Asian Pacific Society of Nephrology.

  20. Contributing factors for therapeutic diet adherence in patients receiving haemodialysis treatment: an integrative review.

    PubMed

    Oquendo, Lissete González; Asencio, José Miguel Morales; de Las Nieves, Candela Bonill

    2017-12-01

    The objective of this integrative review is to identify the factors that contribute to diet adherence in people suffering from kidney disease who are receiving haemodialysis treatment. Adherence to the therapeutic regimen determines therapeutic success, quality of life and survival in patients on haemodialysis. Lack of diet adherence ranges from 25%-86% in patients receiving haemodialysis treatment and affects patient morbidity and mortality. An integrative literature review was conducted based on the criteria of Whittemore & Knafl. A literature review was performed by two members of the team using twelve databases including PubMed, CUIDEN, CINAHL, The Cochrane Library and ScienceDirect. The main issues identified after analysing the results were as follows: the intrinsic barriers (age, dialysis time, motivation, perceived benefit, distorted perception of adherence) and facilitators (self-efficacy, perception of disease, perception of control), extrinsic barriers (family dysfunction, lack of social support, cultural patterns of consumption of food) and facilitators (social support, relationship with healthcare providers), and interventions to encourage diet adherence, such as the use of motivational interviewing in educational interventions, and the training and education of relevant professionals in communication skills. Diet nonadherence remains a serious health problem and suffers from a lack of solid criteria to identify this condition. The onset of depression signs and the level of social support available to the patient should be assessed, because these are important factors that determine adherence to treatment. Professionals should be trained in health education and communication techniques to contribute to the patient's self-management and motivation for diet adherence. Controlled and randomised clinical studies involving predialysis stages should be performed to investigate the impact of the assessment and control of barriers to diet adherence. © 2017

  1. Hypogonadism associated with muscle atrophy, physical inactivity and ESA hyporesponsiveness in men undergoing haemodialysis.

    PubMed

    Cobo, Gabriela; Gallar, Paloma; Di Gioia, Cristina; García Lacalle, Concepción; Camacho, Rosa; Rodriguez, Isabel; Ortega, Olimpia; Mon, Carmen; Vigil, Ana; Lindholm, Bengt; Carrero, Juan Jesús

    Testosterone deficiency (hypogonadism) is common among men undergoing haemodialysis, but its clinical implications are not well characterized. Testosterone is an anabolic hormone that induces erythrocytosis and muscle synthesis. We hypothesized that testosterone deficiency would be associated with low muscle mass, physical inactivity and higher dosages of erythropoietin-stimulating agents (ESA). Single-center cross-sectional study of 57 male haemodialysis patients. None of the patients was undergoing testosterone replacement therapy. Total testosterone was measured in serum. Body composition (by bioelectrical impedance analysis) and physical activity (by the use of pedometers) were assessed. Patients with testosterone levels below the normal range were considered hypogonadal. Mean testosterone level was 321±146ng/dL; 20 patients (35%) were hypogonadal. Hypogonadal patients were older and had lower mean arterial blood pressure, higher interleukin-6 levels, lower lean body mass and higher fat body mass. A negative association between testosterone and normalized ESA dose was found in uni- and multivariate regression analyses. Testosterone levels directly correlated with lean body mass regardless of confounders. Hypogonadal patients had lower physical activity than their counterparts [2753±1784 vs. 4291±3225steps/day (p=0.04)]. The relationship between testosterone and physical activity was independent of age, comorbidities and inflammatory markers, but dependent on the proportion of muscle mass. Hypogonadism is common in our male haemodialysis population and is associated with higher ESA doses, reduced muscle mass and lower physical activity. The link between low testosterone levels and physical inactivity may conceivably relate to reduced muscle mass due to inadequate muscle protein synthesis. Copyright © 2016 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  2. Quality of life, depression, adherence to treatment and illness perception of patients on haemodialysis.

    PubMed

    Nabolsi, Manar M; Wardam, Lina; Al-Halabi, Jehad O

    2015-02-01

    The purpose of this study was to explore the relationship between quality of life, depression, perception of seriousness of illness and adherence to treatment among Jordanian patients with end stage renal disease on maintenance haemodialysis. The study was carried out using a descriptive, correlation design. A convenience sample of 244 participants was recruited from four major dialysis units in Amman. A self-report questionnaire included demographic data, adherence to treatment and perception of seriousness of illness. Quality of Life Index and Beck Depression Inventory were used for data collection. There was a negative correlation between quality of life and depression (r = -0.05, P = 0.000). Depression was higher among women than men, whereas both gender had low quality of life scores. Higher quality of life has been associated with perceived seriousness of illness and more adherence to treatment regimen. This study provides preliminary evidence to develop culturally sensitive nursing strategies to asses and manage depression, enhance quality of life and adherence to treatment of patients on haemodialysis. © 2013 Wiley Publishing Asia Pty Ltd.

  3. A qualitative study of treatment burden among haemodialysis recipients.

    PubMed

    Karamanidou, Christina; Weinman, John; Horne, Rob

    2014-04-01

    This study aims to explore the experience of renal patients undergoing dialysis treatment focusing on beliefs about their illness, prescribed treatment and the challenge of adherence. Interpretative phenomenological analysis was used to analyse the accounts of seven haemodialysis patients. Patients have a range of beliefs about their illness and their treatment consistent with the self-regulatory model of illness, that is, identity, cause, consequences, timeline and cure. Patients sometimes consciously did not act in accordance to advice when they considered an aspect of treatment less important or less easy to adhere to. Psychological factors like beliefs might play a role in non-adherence behaviour.

  4. A study of sertraline in dialysis (ASSertID): a protocol for a pilot randomised controlled trial of drug treatment for depression in patients undergoing haemodialysis.

    PubMed

    Friedli, Karin; Almond, Michael; Day, Clara; Chilcot, Joseph; Gane, Maria da Silva; Davenport, Andrew; Guirguis, Ayman; Fineberg, Naomi; Spencer, Benjamin; Wellsted, David; Farrington, Ken

    2015-10-26

    The prevalence of depression in people receiving haemodialysis is high with estimates varying between 20 and 40 %. There is little research on the effectiveness of antidepressants in dialysis patients with the few clinical trials suffering significant methodological issues. We plan to carry out a study to evaluate the feasibility of conducting a randomised controlled trial in patients on haemodialysis who have diagnosed Major Depressive Disorder. The study has two phases, a screening phase and the randomised controlled trial. Patients will be screened initially with the Beck Depression Inventory to estimate the number of patients who score 16 or above. These patients will be invited to an interview with a psychiatrist who will invite those with a diagnosis of Major Depressive Disorder to take part in the trial. Consenting patients will be randomised to either Sertraline or placebo. Patients will be followed-up for 6 months. Demographic and clinical data will be collected at screening interview, baseline interview and 2 weeks, and every month (up to 6 months) after baseline. The primary outcome is to evaluate the feasibility of conducting a randomised, double blind, placebo pilot trial in haemodialysis patients with depression. Secondary outcomes include estimation of the variability in the outcome measures for the treatment and placebo arms, which will allow for a future adequately powered definitive trial. Analysis will primarily be descriptive, including the number of patients eligible for the trial, drug exposure of Sertraline in haemodialysis patients and the patient experience of participating in this trial. There is an urgent need for this research in the dialysis population because of the dearth of good quality and adequately powered studies. Research with renal patients is particularly difficult as they often have complex medical needs. This research will therefore not only assess the outcome of anti-depressants in haemodialysis patients with depression but

  5. Long-term effects of melatonin on quality of life and sleep in haemodialysis patients (Melody study): a randomized controlled trial.

    PubMed

    Russcher, Marije; Koch, Birgit C P; Nagtegaal, J Elsbeth; van Ittersum, Frans J; Pasker-de Jong, Pieternel C M; Hagen, E Chris; van Dorp, Wim Th; Gabreëls, Bas; Wildbergh, Thierry X; van der Westerlaken, Monique M L; Gaillard, Carlo A J M; Ter Wee, Piet M

    2013-11-01

    The disturbed circadian rhythm in haemodialysis patients results in perturbed sleep. Short term melatonin supplementation has alleviated these sleep problems. Our aim was to investigate the effects of long-term melatonin supplementation on quality of life and sleep. In this randomized double-blind placebo-controlled trial haemodialysis patients suffering from subjective sleep problems received melatonin 3 mg day(-1) vs. placebo during 12 months. The primary endpoint quality of life parameter 'vitality' was measured with Medical Outcomes Study Short Form-36. Secondary outcomes were improvement of three sleep parameters measured by actigraphy and nighttime salivary melatonin concentrations. Sixty-seven patients were randomized. Forty-two patients completed the trial. With melatonin, no beneficial effect on vitality was seen. Other quality of life parameters showed both advantageous and disadvantageous effects of melatonin. Considering sleep, at 3 months sleep efficiency and actual sleep time had improved with melatonin compared with placebo on haemodialysis days (difference 7.6%, 95% CI 0.77, 14.4 and 49 min, 95% CI 2.1, 95.9, respectively). At 12 months none of the sleep parameters differed significantly from placebo. Melatonin salivary concentrations at 6 months had significantly increased in the melatonin group compared with the placebo group. The high drop-out rate limits the strength of our conclusions. However, although a previous study reported beneficial short term effects of melatonin on sleep in haemodialysis patients, in this long-term study the positive effects disappeared during follow up (6-12 months). Also the quality of life parameter, vitality, did not improve. Efforts should be made to elucidate the mechanism responsible for the loss of effect with chronic use. © 2013 The Authors. British Journal of Clinical Pharmacology © 2013 The British Pharmacological Society.

  6. Severe hyperkalaemia resulting from octreotide use in a haemodialysis patient.

    PubMed

    Adabala, Madhuri; Jhaveri, Kenar D; Gitman, Michael

    2010-10-01

    A 48-year-old man, with end-stage renal disease (ESRD) on haemodialysis, presented to the emergency department with sulphonylurea-induced hypoglycaemia. His hypoglycaemia was persistent despite glucose infusion, so he was treated with octreotide. Octreotide administration reversed the hypoglycaemia but also resulted in severe hyperkalaemia. The patient was urgently dialysed, the octreotide was discontinued and his potassium normalized. We believe that the hyperkalaemia was caused by octreotide-induced insulin suppression and resultant impaired cellular potassium uptake. Although octreotide may be an effective therapy in refractory sulphonylurea-induced hypoglycaemia, it should be used with caution in patients on dialysis.

  7. Improving care and efficiency: appointment times in a haemodialysis unit.

    PubMed

    Lunts, P

    2002-01-01

    Shortage of nurses and dialysis spaces and the desire to improve patient care are the two main driving forces in the dialysis field today. This paper suggests that these issues can be addressed by organisational change. We describe a simple, dramatically effective but rarely used example - the effect on a haemodialysis unit of the introduction of patient appointment times. This paper will demonstrate that appointment times can be highly effective in reducing waiting times for patients and in utilizing staff and resources more efficiently, as long as there is commitment from key staff to implement and maintain them effectively

  8. [Cervical disc hernia decompensation complicated by postoperative transitory tetraparesia about long-term haemodialysis patient].

    PubMed

    Caltot, E; Hélaine, L; Cadic, A; Muller, C; Arvieux, C-C

    2011-01-01

    We report a case of a 51-year-old man who underwent a third kidney transplantation that was complicated by tetraparesia due to a C5-C6 cervical disc hernia decompensation in the immediate postoperative period. Preoperative consultation for long-term haemodialysis patients could be perfected by further neurological investigation and additional imagery. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  9. Long-term clinical parameters after switching to nocturnal haemodialysis: a Dutch propensity-score-matched cohort study comparing patients on nocturnal haemodialysis with patients on three-times-a-week haemodialysis/haemodiafiltration.

    PubMed

    Jansz, Thijs Thomas; Özyilmaz, Akin; Grooteman, Muriel P C; Hoekstra, Tiny; Romijn, Marieke; Blankestijn, Peter J; Bots, Michael L; van Jaarsveld, Brigit C

    2018-03-08

    Nocturnal haemodialysis (NHD), characterised by 8-hour sessions ≥3 times a week, is known to improve clinical parameters in the short term compared with conventional-schedule haemodialysis (HD), generally 3×3.5-4 hours a week. We studied long-term effects of NHD and used patients on conventional HD/haemodiafiltration (HDF) as controls. Four-year prospective follow-up of patients who switched to NHD; we compared patients with patients on HD/HDF using propensity score matching. 28 Dutch dialysis centres. We included 159 patients starting with NHD any time since 2004, aged 56.7±12.9 years, with median dialysis vintage 2.3 (0.9-5.1) years. We propensity-score matched 100 patients on NHD to 100 on HD/HDF. Control of hypertension (predialysis blood pressure, number of antihypertensives), phosphate (phosphate, number of phosphate binders), nutritional status and inflammation (albumin, C reactive protein and postdialysis weight) and anaemia (erythropoiesis-stimulating agent (ESA) resistance). Switching to NHD was associated with a non-significant reduction of antihypertensives compared with HD/HDF (OR <2 types 2.17, 95% CI 0.86 to 5.50, P=0.11); and a prolonged lower need for phosphate binders (OR <2 types 1.83, 95% CI 1.10 to 3.03, P=0.02). NHD was not associated with significant changes in blood pressure or phosphate. NHD was associated with significantly higher albumin over time compared with HD/HDF (0.70 g/L/year, 95% CI 0.10 to 1.30, P=0.02). ESA resistance decreased significantly in NHD compared with HD/HDF, resulting in a 33% lower ESA dose in the long term. After switching to NHD, the lower need for antihypertensives, phosphate binders and ESA persists for at least 4 years. These sustained improvements in NHD contrast significantly with the course of these parameters during continued treatment with conventional-schedule HD and HDF. NHD provides an optimal form of dialysis, also suitable for patients expected to have a long waiting time for

  10. Increase in serum magnesium level in haemodialysis patients receiving sevelamer hydrochloride.

    PubMed

    Mitsopoulos, Efstathios; Griveas, Ioannis; Zanos, Stavros; Anagnostopoulos, Konstantinos; Giannakou, Anastasia; Pavlitou, Aikaterini; Sakellariou, Georgios

    2005-01-01

    Clinical studies have shown that sevelamer hydrochloride improves lipid profiles and attenuates the progression of the cardiovascular calcifications in haemodialysis patients. It is known that both of these properties are associated with increased magnesium levels. The effect of sevelamer on serum magnesium level is not well documented. The aim of this study was to determine the effects of sevelamer treatment on serum magnesium in haemodialysis patients and to assess the association of magnesium levels with lipid profiles and intact parathyroid hormone (iPTH). Phosphate binders were discontinued during a two week washout period. Forty-seven patients, whose serum phosphate was greater than 6.0 mg/dl at the end of washout, received sevelamer hydrochloride for eight weeks. The patients were then washed off sevelamer for another two weeks. Mean serum phosphorus concentration declined from 7.5 +/- 1.3 to 6.4 +/- 1.2 mg/dl (P < 0.001), mean serum magnesium levels increased from 2.75 +/- 0.35 to 2.90 +/- 0.41 mg/dl (P < 0.001) and median serum iPTH levels decreased from 297 to 213 pg/ml (P=0.001) during the eight weeks of sevelamer treatment. After the two week post-treatment washout phosphorus levels increased to 7.3 +/- 1.3 mg/dl (P < 0.001), magnesium levels were reduced to 2.77 +/- 0.39 mg/dl (P < 0.001) and iPTH levels increased to 240 pg/ml (P=0.012). No change was observed in serum calcium levels during the sevelamer treatment period and the subsequent washout period. The mean decline in total and low density lipoprotein (LDL) cholesterol during sevelamer treatment was 16.3 and 28.3 (P < 0.001), respectively. The mean increase in high density lipoprotein (HDL) cholesterol and in apolipoprotein A1 was 2.9 +/- 5.8 mg/dl (P=0.004) and 6.8 +/- 11.1 mg/dl (P=0.001), respectively. Multivariate analysis showed that the rise in serum magnesium concentration significantly correlated with reductions in iPTH levels (r=-0.40, P=0.016), but did not have any significant

  11. More hostile dyslipidaemia in chronic kidney disease patients on maintenance haemodialysis than on conservative management.

    PubMed

    Rathi, Teerath Kumar; Dhrolia, Murtaza Fakhruddin; Imtiaz, Salman

    2016-08-01

    To study the pattern of dyslipidaemia in patients with stage-V chronic kidney disease on conservative management and those on maintenance haemodialysis. This comparative observational study was conducted at the Jinnah Postgraduate Medical Centre, Karachi, from February to July, 2008, and comprised stage-V chronic kidney disease patients. The patients were divided in two groups. Those who were on conservative management were placed in Group A, and those who were on maintenance haemodialysis were in Group B. Serum total lipid, cholesterol, triglycerides and high-density lipoprotein for both groups were assayed on chemical analyser and low-density lipoprotein was calculated by Friedwald equation. SPSS 17 was used for data analysis. Of the 120 patients, there were 60(50%) in each group. The mean age of patients in Group A was 46.33±14.56 years and in Group B was 43.4±14.1years. Of all, 64(53.3%) were men and 56(46.7%) were women. Mean systolic and diastolic blood pressure was 134±19.58mmHg and 83.6±14.14mmHg in Group A and 129±19.7mmHg and 79.7±12.1mmHg in Group B. Mean serum total lipid was significantly higher (p<0.01) whereas mean serum cholesterol was significantly lower (p<0.01) in Group B. Comparison of mean serum triglycerides between the groups was also statistically significant (p<0.01) and was high in Group B. Mean serum high-density lipoprotein was lower in Group B (p<0.01). The difference between serum low-density lipoprotein levels was statistically insignificant between the groups (p=0.11). Pattern of dyslipidaemia in patients on maintenance haemodialysis was more hostile than those on conservative management, and posed increased risk of coronary heart disease.

  12. Analysis of nutrition and nutritional status of haemodialysis patients

    PubMed

    Bogacka, Anna; Sobczak-Czynsz, Anna; Kucharska, Elżbieta; Madaj, Małgorzata; Stucka, Katarzyna

    2018-01-01

    Chronic kidney disease (CKD) is a common disease of civilization where nutrition is part of the treatment. Diet therapy is difficult as it is necessary to control the intake of: energy, protein and minerals – Na, K, Ca and P in the daily food rations (DFR). The aim of the study was to assess the nutritional status and diets of haemodialysis (HD) patients. The study involved 141 haemodialysis patients, at the average age of 65.9. The patients were divided into groups taking into consideration their sex and diagnosis for diabetes. The information on the diets were collected using a 7-day dietary recall. In the DFRs the amount of energy and 22 nutrients were calculated. Obtained results were compared with requirements for HD patients. Appropriate nutritional status (measured with BMI) was reported for majority of women (70.6%) and almost half of men, however, excessive weight was recognized in every third female patient and more than half male patients, and type I obesity was noted in 7.8% of men. The analysis of the results showed that diets of all examined patients were deficient in energy and protein (except women with diabetes), whereas the consumption of fat was appropriate in both groups of women. The recommendations with respect to the amount of cholesterol were met but dietary fibre was too low. Intake of vitamins B1, D, C, folates and Ca and Mg was lower and intake of vitamin B12 was higher than recommended. Assessment of the coverage of the demand on nutrients in HD patients should not be based on the analysis of their nutritional status (BMI) only but also on the analysis of diets, especially in case of diabetes.

  13. Therapeutic drug monitoring of antitubercular agents for disseminated Mycobacterium tuberculosis during intermittent haemodialysis and continuous venovenous haemofiltration.

    PubMed

    Sin, J H; Elshaboury, R H; Hurtado, R M; Letourneau, A R; Gandhi, R G

    2018-04-01

    There is a lack of data regarding therapeutic drug monitoring (TDM) of antitubercular agents in the setting of continuous venovenous haemofiltration (CVVH). We describe TDM results of numerous antitubercular agents in a critically ill patient during CVVH and haemodialysis. A 49-year-old man was initiated on treatment for disseminated Mycobacterium tuberculosis. During hospital admission, the patient developed critical illness and required renal replacement therapy. TDM results and pharmacokinetic calculations showed adequate serum concentrations of rifampin, ethambutol and amikacin during CVVH and of rifampin, pyrazinamide, ethambutol and levofloxacin during intermittent haemodialysis. The presence of critical illness and renal replacement therapy can induce pharmacokinetic changes that may warrant vigilant TDM to ensure optimal therapy. To our knowledge, this is the first report to describe TDM for several antitubercular agents during CVVH in a critically patient with disseminated M. tuberculosis. © 2017 John Wiley & Sons Ltd.

  14. Effects of systematic nursing instruction on a low-phosphorus diet, serum phosphorus level and pruritus of patients on haemodialysis.

    PubMed

    Cheng, Ting-Yin; Tarng, Der-Cherng; Liao, Yuan-Mei; Lin, Pi-Chu

    2017-02-01

    To investigate the effectiveness of systematic nursing instruction on a low-phosphorus diet, serum phosphorus level and pruritus of haemodialysis patients. A high number of end-stage renal disease patients on haemodialysis are bothered by pruritus. Hyperphosphataemia was reported to be related to pruritus. An experimental design was applied. Ninety-four patients who received haemodialysis between September 2013 and December 2013 at a medical centre in Taipei, Taiwan, were recruited. An experimental group received individual systematic nursing instruction by the investigator through a nursing instruction pamphlet and reminder card for taking medication. A control group received traditional nursing instruction. The pruritus, blood phosphorus level and five-day diet records were evaluated before and after intervention. The experimental group had a low-phosphorus diet intake compared with the control group (p < 0·001). A significant difference in serum phosphorus level was observed between the experimental and control groups (p = 0·002). Incidence of pruritus was lower in the experimental group than in the control group (p < 0·001). A systematic nursing instruction included using a pamphlet, pictures and reminder cards, the patients' blood phosphorus levels decreased, the patients consumed more low-phosphorus food, and pruritus decreased. This study recommends that clinical nursing staff include systematic nursing instruction as a routine practice for dialysis patients. © 2016 John Wiley & Sons Ltd.

  15. [Thrombosis in vascular accesses for haemodialysis: rescue treatment using invasive vascular radiological techniques].

    PubMed

    García Medina, J; Lacasa Pérez, N; Muray Cases, S; Pérez Garrido, I; García Medina, V

    2009-01-01

    The purpose of this paper is to communicate our experience in the salvage of thrombosed haemodialysis vascular accesses using interventional radiology techniques. In the last four years, we have treated, by radiological means, 101 thrombosed haemodialysis vascular accesses. There were 44 autologous arteriovenous fistulas (43.56%) and 57 PTFE grafts (56.44%). There were 69 men (68.3%) and 32 women (31.7%). The mean age was 67.73 years (range 33-84). The mean vascular access age was 23.79 months (range 1-132). Manual catheter-directed aspiration was used. Fragmented, triturated or pushed the thrombus against the pulmonary circulation was avoided in all cases. 78 accesses were salvaged (77.2%). Autologous fistulas average and PTFE grafts success rate were 84.44% and 71.42% respectively. Angioplasty in one or more lesions after thromboaspiration was performed in all accesses, except six (5.9%). Metallic endoprostheses were implanted in 14 accesses (13.9%). Mean follow-up was 9 months (range 0-44). Primary patency was 42.3% +/- 5 at 6 months and 32% +/- 4 at one year. Autologous fistulas patency was better than PTFE grafts patency (p < or =0,05). Our results suggest thrombosed autologous arteriovenous fistulas salvage is better than PTFE grafts. This justifies interventional radiology techniques in these situations.

  16. Determination of functional iron deficiency status in haemodialysis patients in central South Africa.

    PubMed

    Haupt, L; Weyers, R

    2016-08-01

    Functional iron deficiency (FID) is characterized by adequate body iron stores with an inadequate rate of iron delivery for erythropoiesis. In chronic kidney failure (CKD), iron availability is best assessed using the percentage of hypochromic red cells (%Hypo). The aim of our study was to determine the FID status of haemodialysis patients in central South Africa, using the %Hypo analyte and to evaluate the ability of the currently used biochemical tests, transferrin saturation (TSat) and serum ferritin to diagnose FID. For this study, 49 patients on haemodialysis were recruited. Haemoglobin (Hb), mean cell volume (MCV) and %Hypo were measured on the Advia 2120i. Biochemical analytes (serum ferritin, TSat) and C-reactive protein (CRP) levels were also recorded. Of the 49 participants, 21 (42.9%) were diagnosed with FID (%Hypo >6%). A large number of patients (91.8%) were anaemic. The TSat demonstrated poor sensitivity and specificity for diagnosing FID compared with %Hypo. The use of %Hypo (rather than TSat) to guide intravenous iron use spared 16 patients the potential harmful effects thereof. Using %Hypo as a single analyte to diagnose FID will lead to more appropriate use of limited resources and a reduction in treatment-related complications. © 2016 John Wiley & Sons Ltd.

  17. Validity and reliability of Turkish Caregiver Burden Scale among family caregivers of haemodialysis patients.

    PubMed

    Cil Akinci, Ayse; Pinar, Rukiye

    2014-02-01

    To investigate the validity and reliability of the Caregiver Burden Scale in family members who provide primary care for haemodialysis patients. In Turkey, there is a need for a multi-dimensional instrument to evaluate the caregiver burden in people who provide care for patients with chronic diseases. A methodological study. The study sample consisted of 161 family members who provide primary care for haemodialysis patients. The forward-backward translation method was used to develop the Turkish Caregiver Burden Scale. The reliability was based on internal consistency investigated by Cronbach's alpha and item-total correlation. The factorial construct validity of the scale was tested with confirmatory factor analysis. By means of convergent and divergent validity, correlation between Caregiver Burden Scale and 36-Item Short Form Health Survey (SF-36) and correlation between Caregiver Burden Scale and the Maslach Burnout Scale were investigated. Cronbach's alpha and item-total correlations results suggested that there was good internal reliability. We found five underlying factors similar to original Scale's five-factor solution. The confirmatory factor analysis five-factor model represented an acceptable fit. Factor loadings were significant, with standardised loadings ranging from 0·43-0·81. By means of divergent validity, all sub-dimension scores and the total score of the Caregiver Burden Scale were negatively correlated with the SF-36, whereas there was a positive correlation with the emotional exhaustion and depersonalisation subscales of the Maslach Burnout Scale as expected. These results suggest that the Caregiver Burden Scale is a reliable and valid instrument which can be used with confidence in Turkish caregivers for haemodialysis patients to screen caregiver burden. The burden experienced by people who provide care for patients with chronic diseases can be evaluated with the Caregiver Burden Scale. Additionally, the Caregiver Burden Scale can be used

  18. Low-dose cholecalciferol supplementation and dual vitamin D therapy in haemodialysis patients.

    PubMed

    Dusilová-Sulková, Sylvie; Šafránek, Roman; Vávrová, Jaroslava; Horáček, Jiří; Pavlíková, Ladislava; Palička, Vladimír

    2015-01-01

    Traditionally, secondary hyperparathyroidism (SHPT) due to low calcitriol synthesis in failing kidneys has been treated with synthetic vitamin D receptor (VDR) activators. Recently, also the importance of low native vitamin D status beyond the issue of SHPT has been recognized in these patients. The aim of this work was to evaluate the effect of cholecalciferol supplementation in haemodialysis patients with low vitamin D serum levels. Another aim was to evaluate dual vitamin D therapy (cholecalciferol supplementation plus paricalcitol) in haemodialysis patients with vitamin D deficiency and concomitant SHPT. Ninety clinically stable maintenance haemodialysis patients were included. Supervised cholecalciferol supplementation was administered due to low vitamin D status. Patients with SHPT were also treated with synthetic VDR activator. Two pre hoc subgroups for statistical analysis were formed: patients treated solely with cholecalciferol (N=34; 5,000 IU once weekly) and patients treated with a combination of cholecalciferol (identical dose, i.e. 5,000 IU/week) plus paricalcitol (N=34, median dose 10 μg/week). Follow-up visit was scheduled 15 weeks later. Serum concentrations of calcidiol (25-D), parathyroid hormone (PTH) and beta-cross laps (CTX) were assessed at baseline and at follow-up. Serum calcium, phosphate and alkaline phosphatase (ALP) were monitored monthly. Only non-calcium gastrointestinal phosphate binders were administered. Dialysate calcium was 1.5 mmol/L in all patients, and no oral calcium-containing preparations were prescribed. Depending on data distribution, parametric or nonparametric statistical methods were used for comparison within each group (i.e. baseline vs. follow-up data) as well as between groups. In the whole group of 90 patients, mean baseline 25-D serum level was 20.3 (standard deviation 8.7) nmol/L, and it increased to 66.8 (19) nmol/L (p<0.0001) after supplementation. In both preformed subgroups, the effect of vitamin D

  19. High levels of serum fibroblast growth factor (FGF)-23 are associated with increased mortality in long haemodialysis patients.

    PubMed

    Jean, Guillaume; Terrat, Jean-Claude; Vanel, Thierry; Hurot, Jean-Marc; Lorriaux, Christie; Mayor, Brice; Chazot, Charles

    2009-09-01

    Fibroblast growth factor (FGF)-23, a novel bone-derived phosphaturic factor involved in mineral metabolism, is increased in chronic kidney disease (CKD); in dialysis patients, it has been linked to increased mortality rates and vascular calcification (VC). The present investigation aimed to study the factors associated with elevated serum FGF-23 levels in patients treated with long haemodialysis (LHD) sessions and to determine whether a relationship exists between serum FGF-23 levels and patient survival. All patients treated in one haemodialysis centre from September 2006 were included in the study. Standard laboratory values, medical history, cardiovascular events and risk factors, medication and FGF-23 levels [ELISA (C-Term) Immutopics] were recorded. Patients received haemodialysis three times a week, on a 5- to 8-h schedule. Patient data were analysed according to FGF-23 quartiles. The effect of FGF-23 on the 2-year survival rate was assessed using the Cox proportional hazard model, adjusted for confounding variables and according to the serum phosphate tertiles. The study included 219 patients. Serum FGF-23 levels were high: 7060 +/- 13 500 RU/mL (median, 2740 RU/mL). In logistical regressions, only calcaemia (P = 0.002), phosphataemia (P = 0.008) and warfarin use (P = 0.04) were associated with the highest FGF-23 quartile. In the subgroup of patients with an estimated VC score, the third and fourth quartiles of the FGF-23 levels were associated with more severe VC. In multivariate linear regressions, only phosphataemia remained significantly correlated with FGF-23 (P = 0.04). The 2-year mortality rate was significantly higher for haemodialysis patients with serum FGF-23 levels in the higher quartile [P = 0.007; hazard ratio, 2.5 (1.3-5)] than in the first quartile, whereas within the phosphataemia tertiles, the lowest serum FGF-23 quartile was associated with lowered mortality. This study demonstrated a high level of circulating FGF-23 in LHD patients

  20. Septic arthritis in haemodialysis patients: a seven-year multi-centre review.

    PubMed

    Al-Nammari, S S; Gulati, V; Patel, R; Bejjanki, N; Wright, M

    2008-04-01

    To determine relevant demographics, clinical features, and outcomes for septic arthritis in patients on haemodialysis for end-stage renal failure. A multi-centre retrospective review was performed from 1999 to 2005. 15 cases were identified. The mean age of the patients at diagnosis was 67 (range, 23-89) years and 11 were male. All had multiple co-morbidities and additional risk factors for sepsis. The primary sources of sepsis were dialysis access-related (n=12), unknown in 2, and unrelated soft tissue infection in one. All patients presented with acute monoarticular symptoms; the knee joint was affected in 11 patients. The white cell count, neutrophil count, and C-reactive protein concentration were elevated in 10, 10, and 15 patients, respectively. All patients had positive synovial fluid cultures and blood cultures were positive in 14. Organisms isolated were all skin commensals, being staphylococcal in 13 and streptococcal in 2. Six patients had concomitant rheumatological disease (gout in 4, pseudogout in one, and rheumatoid arthritis in one). Two had urate crystals in the synovial fluid (noted by microscopy). All patients underwent antimicrobial therapy for a mean of 36 days, together with joint washouts and debridement. 12 patients were cured of infection; 2 developed chronic sepsis secondary to localised osteomyelitis; and one died of sepsis. Septic arthritis is a potentially devastating condition. Early and aggressive joint lavage and debridement combined with appropriate antimicrobial therapy is imperative. A high index of suspicion is necessary in haemodialysis patients; the diagnosis of septic arthritis must be presumed until proven otherwise.

  1. Influence of Erythropoiesis-Stimulating Agents on HbA1c and Fructosamine in Patients with Haemodialysis.

    PubMed

    Rasche, Franz Maximilian; Ebert, Thomas; Beckmann, Julia; Busch, Volker; Barinka, Filip; Rasche, Wilma Gertrud; Lindner, Tom H; Schneider, Jochen G; Schiekofer, Stephan

    2017-06-01

    HbA1c is the most accepted laboratory parameter for the long term observation of glucose control. There is still much of a debate about the use of HbA1c as a metabolic indicator in diabetic patients (DM) on haemodialysis (HD) and erythropoiesis-stimulating agent (ESA) therapy because of the altered erythrocyte turn over in patients with chronic kidney disease and haemodialysis (CKD5D). In 102 CKD5 patients with and without diabetes mellitus, we examined the dose dependent variability in HbA1c and fructosamine levels under haemodialysis and treated with epoetin α (n=48) and a new generation agent with continuous stimulation of methoxy polyethylene glycol epoetin beta (C.E.R.A.; n=54). HbA1c levels were affected by therapy with ESA treatments. ESA dose was inversely correlated with HbA1c and an escalation of 10.000 IU per week induced an estimated decrease of HbA1c of 0.6 percent. In addition, the increase of reticulocyte number as a marker for erythropoiesis was significantly inversely correlated with the increase of ΔHbA1c. ESA treatments had no such effect on the alternative metabolic parameter fructosamine. When compared, both therapeutic agents had comparable success in attaining haemoglobin (Hb) target values. C.E.R.A. showed better correlation and was more effective over a longer dose interval. Our results show that HbA1c levels in patients should be carefully interpreted based on interfering factors. Nevertheless, HbA1c is currently the most consistent parameter for use ascertaining metabolic status of patients suffering from diabetes mellitus. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Dental and periodontal health, and microbiological and salivary conditions in patients with or without diabetes undergoing haemodialysis.

    PubMed

    Schmalz, Gerhard; Schiffers, Nora; Schwabe, Sandra; Vasko, Radovan; Müller, Gerhard A; Haak, Rainer; Mausberg, Rainer F; Ziebolz, Dirk

    2017-06-01

    The aim of this cross-sectional study was to evaluate the dental and periodontal health, as well as the microbiological and salivary conditions, of patients with and without diabetes mellitus (DM) who are receiving haemodialysis. One-hundred and fifty-nine haemodialysis patients were included and divided into groups according to the pre-existing diabetes status: DM or no DM. The oral examination included dental findings and assessment of the periodontal situation. The periodontal condition was classified as healthy/mild, moderate or severe periodontitis. Subgingival biofilm samples were analysed using the polymerase chain reaction. The salivary diagnostics included measurement of unstimulated and stimulated salivary flow, pH and buffer capacity. Statistical analyses used Fisher's test, the t-test and the Mann-Whitney U-test (α = 5%). The dental findings showed no significant difference between patients with and without DM (P = 0.44). The prevalence of periodontitis was high (96% in patients with DM and 97% in patients who did not have DM) and there was no significant difference between the groups (P = 0.71). There was a higher prevalence of Porphyromonas gingivalis, Parvimonas micros, Eubacterium nucleatum and Capnocytophaga spp. in patients without DM (P < 0.05). The salivary pH was significantly higher in patients without DM (P < 0.01). While differences in the prevalence of periodontal pathogenic bacteria and in the salivary pH were detected between the groups, the dental and periodontal status was comparable between patients with and without DM. Accordingly, DM appears to have no decisive influence on the oral health in patients treated with haemodialysis who have well-controlled diabetes. © 2017 FDI World Dental Federation.

  3. Serratia marcescens bacteraemia outbreak in haemodialysis patients with tunnelled catheters due to colonisation of antiseptic solution. Experience at 4 hospitals.

    PubMed

    Merino, José L; Bouarich, Hanane; Pita, Mª José; Martínez, Patricia; Bueno, Blanca; Caldés, Silvia; Corchete, Elena; Jaldo, Mª Teresa; Espejo, Beatriz; Paraíso, Vicente

    The application of antiseptic solution for handling tunnelled catheters is recommended in patients undergoing haemodialysis. These routine antiseptic procedures in handling catheters are crucial to avoid complications. We report an outbreak of Serratia marcescens (S. marcescens) bacteraemia in numerous haemodialysis units of the Community of Madrid. The first cases of bacteraemia due to S. marcescens were isolated in December 2014. The Preventive Medicine Services were informed of the detection of an atypical pathogen in several patients, suspecting a probable nosocomial outbreak. Information from 4 centres with similar S. marcescens bacteraemia was analysed. Twenty-one cases of bacteraemia related to S. marcescens were identified. The mean age of affected patients was 72±10 years. The mean time on haemodialysis of affected patients was 33±13 months (range: 3-83 months), the median time of tunnelled catheter was 22±13 months. In 11 cases the clinical picture was similar, with hypotension and general malaise during the haemodialysis session. Fever was present in a further 7 cases. In 3 cases the presentation was asymptomatic and was detected by blood cultures. All patients had tunnelled catheters (12 patients with catheter in the right jugular vein, 5 in the left jugular, 2 in the right femoral artery and 2 in the left subclavian artery). Gentamicin intravenous doses (1mg/kg) with catheter lock solution with ciprofloxacin post-dialysis were administered for 3 weeks in 6 patients. In 12 patients the treatment was ceftazidime (2g IV) plus catheter lock solution with the same antibiotic, for 2 weeks. Four patients received oral ciprofloxacin for 2 weeks, in one case together with IV vancomycin. The patients were asymptomatic and without new episodes 48hours after the treatment. No major complications were observed. The teams informed the health authorities of the situation, which then reported the presence of batches of antiseptic (chlorhexidine 0.05 and 2

  4. Bovine and porcine heparins: different drugs with similar effects on human haemodialysis

    PubMed Central

    2013-01-01

    Background Heparins from porcine and bovine intestinal mucosa differ in their structure and also in their effects on coagulation, thrombosis and bleeding. However, they are used as undistinguishable drugs. Methods We compared bovine and porcine intestinal heparin administered to patients undergoing a particular protocol of haemodialysis. We compared plasma concentrations of these two drugs and also evaluated how they affect patients and the dialyzer used. Results Compared with porcine heparin, bovine heparin achieved only 76% of the maximum plasma concentration as IU mL-1. This observation is consistent with the activities observed in the respective pharmaceutical preparations. When the plasma concentrations were expressed on weight basis, bovine heparin achieved a maximum concentration 1.5 fold higher than porcine heparin. The reduced anticoagulant activity and higher concentration, on weight basis, achieved in the plasma of patients under dialysis using bovine instead of porcine heparin did not affect significantly the patients or the dialyzer used. The heparin dose is still in a range, which confers security and safety to the patients. Discussion Despite no apparent difference between bovine and porcine intestinal heparins in the haemodialysis practice, these two types of heparins should be used as distinct drugs due to their differences in structure and biological effects. Conclusions The reduced anticoagulant activity achieved in the plasma of patients under dialysis using bovine instead of porcine heparin did not affect significantly the patients or the dialyzer. PMID:23763719

  5. Paricalcitol versus cinacalcet plus low-dose vitamin D for the treatment of secondary hyperparathyroidism in patients receiving haemodialysis: study design and baseline characteristics of the IMPACT SHPT study

    PubMed Central

    Martin, Kevin J.; Cozzolino, Mario; Goldsmith, David; Sharma, Amit; Khan, Samina; Dumas, Emily; Amdahl, Michael; Marx, Steven; Audhya, Paul

    2012-01-01

    Background. Paricalcitol and cinacalcet are common therapies for patients on haemodialysis with secondary hyperparathyroidism (SHPT). We conducted a multi-centre study in 12 countries to compare the safety and efficacy of paricalcitol and cinacalcet for the treatment of SHPT. Methods. Patients aged ≥18 years with Stage 5 chronic kidney disease receiving maintenance haemodialysis and with intact parathyroid hormone (iPTH) 300–800 pg/mL, calcium 8.4–10.0 mg/dL (2.09–2.49 mmol/L) and phosphorus ≤6.5 mg/dL (2.09 mmol/L) were randomized within two strata defined by the mode of paricalcitol administration to treatment with paricalcitol- (intra-venous, US and Russian sites, IV stratum; oral, non-US and non-Russian sites, oral stratum) or cinacalcet-centred therapy. The primary endpoint is the proportion of patients in each treatment group who achieve a mean iPTH value of 150–300 pg/mL during Weeks 21–28 of treatment. Assuming efficacy response rates of 36 and 66% for cinacalcet and paricalcitol, respectively, and a 20% discontinuation rate, 124 subjects in each stratum were estimated to provide 81% power to detect a 30% absolute difference in the primary endpoint. Results. Of 746 patients screened, 272 (mean age, 63 years; mean iPTH, 509 pg/mL) were randomized. Mean duration of haemodialysis at baseline was 3.7 years. Comorbidities included hypertension (90.4%), Type 2 diabetes (40.4%), congestive heart failure (17.3%), coronary artery disease (34.6%) and gastrointestinal disorders (75%). Conclusions. The study participants are representative of a multinational cohort of patients on haemodialysis with elevated iPTH. The study results will provide valuable information on the best available treatment of SHPT in patients on haemodialysis. PMID:21931122

  6. Vitamin C deficiency and secondary hyperparathyroidism in chronic haemodialysis patients.

    PubMed

    Richter, Anja; Kuhlmann, Martin K; Seibert, Eric; Kotanko, Peter; Levin, Nathan W; Handelman, Garry J

    2008-06-01

    Maintenance haemodialysis patients often suffer from secondary hyperparathyroidism and serum parathyroid hormone levels may be influenced by nutritional variables. We examined serum bio-intact parathyroid hormone (BiPTH) and plasma vitamin C in 117 chronic haemodialysis patients. Plasma vitamin C was measured by high-performance liquid chromatography with electrochemical detection, on samples collected before start of the dialysis treatment. Plasma vitamin C showed a significant positively skewed distribution, ranging from <2 microM to >300 microM. We found 15% (n = 17) of the patients with severe vitamin C deficiency (<10 microM), 66% (n = 77) in the range 10-80 microM, and 19% (n = 23) with plasma vitamin C >80 microM, the upper limit of normal for non-renal disease population. High plasma vitamin C was associated with lower plasma BiPTH (P = 0.005, one-way analysis of variance), and this association persisted after stepwise multiple regression for other factors known to influence PTH. Low vitamin C levels were also associated with increased serum alkaline phosphatase, a further indicator of the impact of vitamin C status on bone metabolism. Patients who reported dietary vitamin C intake of >or=100 mg/day had lower BiPTH (P = 0.015), consistent with findings from plasma measurements of vitamin C. This novel observation of the interaction between PTH and vitamin C may result from effects of vitamin C on cAMP-linked signalling pathways in bone and parathyroid gland. This finding does not yet warrant therapeutic intervention with supplemental vitamin C to remedy secondary hyperparathyroidism. However, further research may indicate a key interaction between vitamin C and the parathyroid hormone linked signalling pathways, and may uncover mechanisms of therapeutic importance.

  7. A randomized, open-label trial of iron isomaltoside 1000 (Monofer®) compared with iron sucrose (Venofer®) as maintenance therapy in haemodialysis patients.

    PubMed

    Bhandari, Sunil; Kalra, Philip A; Kothari, Jatin; Ambühl, Patrice M; Christensen, Jeppe H; Essaian, Ashot M; Thomsen, Lars L; Macdougall, Iain C; Coyne, Daniel W

    2015-09-01

    Iron deficiency anaemia is common in patients with chronic kidney disease, and intravenous iron is the preferred treatment for those on haemodialysis. The aim of this trial was to compare the efficacy and safety of iron isomaltoside 1000 (Monofer®) with iron sucrose (Venofer®) in haemodialysis patients. This was an open-label, randomized, multicentre, non-inferiority trial conducted in 351 haemodialysis subjects randomized 2:1 to either iron isomaltoside 1000 (Group A) or iron sucrose (Group B). Subjects in Group A were equally divided into A1 (500 mg single bolus injection) and A2 (500 mg split dose). Group B were also treated with 500 mg split dose. The primary end point was the proportion of subjects with haemoglobin (Hb) in the target range 9.5-12.5 g/dL at 6 weeks. Secondary outcome measures included haematology parameters and safety parameters. A total of 351 subjects were enrolled. Both treatments showed similar efficacy with >82% of subjects with Hb in the target range (non-inferiority, P = 0.01). Similar results were found when comparing subgroups A1 and A2 with Group B. No statistical significant change in Hb concentration was found between any of the groups. There was a significant increase in ferritin from baseline to Weeks 1, 2 and 4 in Group A compared with Group B (Weeks 1 and 2: P < 0.001; Week 4: P = 0.002). There was a significant higher increase in reticulocyte count in Group A compared with Group B at Week 1 (P < 0.001). The frequency, type and severity of adverse events were similar. Iron isomaltoside 1000 and iron sucrose have comparative efficacy in maintaining Hb concentrations in haemodialysis subjects and both preparations were well tolerated with a similar short-term safety profile. © The Author 2015. Published by Oxford University Press on behalf of ERA-EDTA.

  8. Predictors of dietary and fluid non-adherence in Jordanian patients with end-stage renal disease receiving haemodialysis: a cross-sectional study.

    PubMed

    Khalil, Amani A; Darawad, Muhammad; Al Gamal, Eklas; Hamdan-Mansour, Ayman M; Abed, Mona A

    2013-01-01

    The purpose of this study is to provide insight into the relationship between dietary and fluid non-adherence, depressive symptoms, quality of life, perceived barriers and benefits of exercise, and perceived social support among Jordanian patients with end-stage renal disease receiving haemodialysis using Pender's health promotion model. Non-adherence to dietary and fluid restrictions is a leading cause of treatment failure and poor outcomes in end-stage renal disease. Yet, factors that interfere with the patients' ability to follow their dietary restrictions are unknown. A descriptive, correlational, cross-sectional design was used. Jordanian patients (n = 190) with end-stage renal disease receiving haemodialysis from three main Jordanian cities were included. The dialysis diet and fluid nonadherence questionnaire, Beck Depression Inventory-II, Quality Of Life Index, Dialysis Patient-Perceived Exercise Benefits and Barriers Scale, and the Multidimensional Perceived Social Support were employed to measure the key variables. Patients were more likely men with mean age of 48·2 ± 14·9. Only 27% of the patients showed full commitment to diet guidelines and 23% to fluid guidelines during the last 14 days. Depression (M = 18·8 ± 11·4) had significant negative association with quality of life (importance and satisfaction) (r = -0·60, r = -0·32, p = 0·001, respectively). Multiple hierarchal regressions revealed a predictive model of only two variables: age (B = -0·22, p = 0·05) and residual renal function (B = -0·23, p = 0·012) for dietary non-adherence. Non-adherence to diet and fluid guidelines association with individual characteristics, health perception and psychosocial variables should be investigated in a longitudinal design. Relationship of non-adherence with culture-related factors should deeply be assessed among Jordanian patients with end-stage renal disease receiving haemodialysis. Identification of the factors that may worsen dietary and fluid non

  9. Gender differences in the effect of fish oil on appetite, inflammation and nutritional status in haemodialysis patients.

    PubMed

    Zabel, R; Ash, S; King, N; Naslund, E; Bauer, J

    2010-08-01

    Haemodialysis patients show signs of chronic inflammation and reduced appetite, which is associated with a worse clinical status and an increased mortality risk. Fish oil has anti-inflammatory properties and may be useful as a therapeutic treatment. There is limited evidence to indicate the feasibility and efficacy of this intervention in dialysis patients. The present study aimed to compare the effect of 12 weeks of supplementation with fish oil on markers of appetite and inflammation in male and female haemodialysis patients. The study was conducted in 28 haemodialysis patients. All patients were prescribed 3 g of fish oil per day for 12 weeks. Changes in appetite, plasma fatty acid profiles and inflammatory markers were measured at baseline and at 12 weeks. The mean (SD) increase in percent plasma eicosapentaenoic acid was statistically significant [1.1 (0.8) to 4.1 (2.2), P < 0.001], which was a strong indicator of good adherence. There were trends towards reductions in peptide YY (-9%; P = 0.078) and an increase in subjective sensations of hunger (+12%; P = 0.406), which reflects an increase in motivation to eat. Males (n = 13) experienced a more marked increase in hunger compared to females (+23% versus -6%), which was associated with maintenance in C-reactive protein and interleukin-6, and a reduction in soluble intercellular adhesion molecule-1. The results obtained demonstrate meaningful trends towards improvements in subjective appetite and certain inflammatory markers (although no change in dietary intake) and this effect was more pronounced in males. However, the levels of some inflammatory markers increased in females and this requires further study. The high level of adherence achieved indicates that an intervention requiring patients to consume four fish oil capsules per day is achievable. This was a short-term study and the effects need to be confirmed in a randomised controlled trial.

  10. An exploration of the relationship between fatigue and physical functioning in patients with end stage renal disease receiving haemodialysis.

    PubMed

    O'Sullivan, Dawn; McCarthy, Geraldine

    2007-11-01

    To measure fatigue and physical functioning in patients with end stage renal disease (ESRD) receiving haemodialysis and to investigate the relationships between fatigue and physical functioning. Fatigue and reduced physical functioning are among the most bothersome symptoms experienced by individuals receiving haemodialysis for ESRD. Research has shown that increasing activity levels has resulted in decreased fatigue levels and improved physical functioning in individuals with cancer. Establishing whether or not a relationship exists between both concepts in haemodialysis patients is a preliminary step in identifying potential fatigue reducing strategies necessary for improved wellbeing. A quantitative exploratory correlational design was used with 46 individuals completing the Multi-dimensional Fatigue Inventory, the Medical Outcomes Study Short-Form 36-item questionnaire and a Demographic Questionnaire. Results indicated fatigue was prevalent with highest scores achieved for physical fatigue; reduced activity and general fatigue. Substantial limitations in physical functioning were found. A significant moderate negative relationship between general fatigue and physical functioning indicated that, as physical functioning levels increased, fatigue levels decreased. A significant difference was also found between general fatigue scores for males and females. Significant relationships were found between overall physical functioning, older age and employment status. The research indicates the prevalence of fatigue and limitations in physical functioning in individuals with ESRD. However, as physical functioning increased fatigue decreased; a finding relevant to clinical nursing. Understanding the levels of fatigue and the value of exercise is of relevance to clinical practice thus assessment of fatigue and physical functioning ability in the clinical setting is necessary.

  11. Randomised factorial mixed method pilot study of aerobic and resistance exercise in haemodialysis patients: DIALY-SIZE!

    PubMed Central

    Thompson, Stephanie; Klarenbach, Scott; Molzahn, Anita; Lloyd, Anita; Gabrys, Iwona; Haykowsky, Mark; Tonelli, Marcello

    2016-01-01

    Objectives For people with end-stage renal disease requiring haemodialysis, exercise can improve aspects of quality of life (QoL). However, the relative benefits and risks of different types of exercise in this population are unknown. Therefore, this pilot study aimed to evaluate the feasibility of a main study evaluating the efficacy of cycling and resistance exercise each performed during the haemodialysis treatment on QoL. Methods In this factorial (2×2) pilot trial, 31 haemodialysis patients were randomised to cycling, resistance, cycling and resistance, or an attention control. Feasibility was defined a priori by criteria on recruitment, fidelity to the protocol and patient response to the intervention. To better understand feasibility, we conducted interviews with dialysis unit staff and trial participants. As secondary outcomes, we estimated the main effect of cycling and weights each compared with control on QoL, physical function and strength. Findings We exceeded the target accrual of 28 participants over 12 weeks. Irrespective of exercise group allocation, adherence was high; of the 1038 training sessions offered, 87% were initiated and over 80% of exercise sessions were performed as per protocol. Progression based on perceived exertion, individual instruction and interactions with the kinesiologist facilitated acceptability across exercise groups. Using an attention control, measures of contamination and attrition were low. Important barriers to unit staff readiness for the intervention were initial safety and workflow concerns, unit workload and onerous data collection. Secondary outcomes were not statistically significant. Adverse events were low and did not increase with a higher volume of exercise. Conclusions The main study is feasible with minor modifications. In addition to practical assistance, involvement from unit staff could increase patient participation and improve trial implementation. Strategies to increase acceptability of the

  12. Assessing the blood volume and heart rate responses during haemodialysis in fluid overloaded patients using support vector regression.

    PubMed

    Javed, Faizan; Savkin, Andrey V; Chan, Gregory S H; Middleton, Paul M; Malouf, Philip; Steel, Elizabeth; Mackie, James; Lovell, Nigel H

    2009-11-01

    This study aims to assess the blood volume and heart rate (HR) responses during haemodialysis in fluid overloaded patients by a nonparametric nonlinear regression approach based on a support vector machine (SVM). Relative blood volume (RBV) and electrocardiogram (ECG) was recorded from 23 haemodynamically stable renal failure patients during regular haemodialysis. Modelling was performed on 18 fluid overloaded patients (fluid removal of >2 L). SVM-based regression was used to obtain the models of RBV change with time as well as the percentage change in HR with respect to RBV. Mean squared error (MSE) and goodness of fit (R(2)) were used for comparison among different kernel functions. The design parameters were estimated using a grid search approach and the selected models were validated by a k-fold cross-validation technique. For the model of HR versus RBV change, a radial basis function (RBF) kernel (MSE = 17.37 and R(2) = 0.932) gave the least MSE compared to linear (MSE = 25.97 and R(2) = 0.898) and polynomial (MSE = 18.18 and R(2)= 0.929). The MSE was significantly lower for training data set when using RBF kernel compared to other kernels (p < 0.01). The RBF kernel also provided a slightly better fit of RBV change with time (MSE = 1.12 and R(2) = 0.91) compared to a linear kernel (MSE = 1.46 and R(2) = 0.88). The modelled HR response was characterized by an initial drop and a subsequent rise during progressive reduction in RBV, which may be interpreted as the reflex response to a transition from central hypervolaemia to hypovolaemia. These modelled curves can be used as references to a controller that can be designed to regulate the haemodynamic variables to ensure the stability of patients undergoing haemodialysis.

  13. Barriers and facilitators to healthcare professional behaviour change in clinical trials using the Theoretical Domains Framework: a case study of a trial of individualized temperature-reduced haemodialysis.

    PubMed

    Presseau, Justin; Mutsaers, Brittany; Al-Jaishi, Ahmed A; Squires, Janet; McIntyre, Christopher W; Garg, Amit X; Sood, Manish M; Grimshaw, Jeremy M

    2017-05-22

    Implementing the treatment arm of a clinical trial often requires changes to healthcare practices. Barriers to such changes may undermine the delivery of the treatment making it more likely that the trial will demonstrate no treatment effect. The 'Major outcomes with personalized dialysate temperature' (MyTEMP) is a cluster-randomised trial to be conducted in 84 haemodialysis centres across Ontario, Canada to investigate whether there is a difference in major outcomes with an individualized dialysis temperature (IDT) of 0.5 °C below a patient's body temperature measured at the beginning of each haemodialysis session, compared to a standard dialysis temperature of 36.5 °C. To inform how to deploy the IDT across many haemodialysis centres, we assessed haemodialysis physicians' and nurses' perceived barriers and enablers to IDT use. We developed two topic guides using the Theoretical Domains Framework (TDF) to assess perceived barriers and enablers to IDT ordering and IDT setting (physician and nurse behaviours, respectively). We recruited a purposive sample of haemodialysis physicians and nurses from across Ontario and conducted in-person or telephone interviews. We used directed content analysis to double-code transcribed utterances into TDF domains, and inductive thematic analysis to develop themes. We interviewed nine physicians and nine nurses from 11 Ontario haemodialysis centres. We identified seven themes of potential barriers and facilitators to implementing IDTs: (1) awareness of clinical guidelines and how IDT fits with local policies (knowledge; goals), (2) benefits and motivation to use IDT (beliefs about consequences; optimism; reinforcement; intention; goals), (3) alignment of IDTs with usual practice and roles (social/professional role and identity; nature of the behaviour; beliefs about capabilities), (4) thermometer availability/accuracy and dialysis machine characteristics (environmental context and resources), (5) impact on workload (beliefs

  14. The effect of vegetarian diet on skin autofluorescence measurements in haemodialysis patients.

    PubMed

    Nongnuch, Arkom; Davenport, Andrew

    2015-04-14

    CVD remains the major cause of death for dialysis patients. Dialysis patients have both traditional and nontraditional risk factors, including the retention of advanced glycation end products (AGE). Tissue AGE can be measured by skin autofluorescence (SAF) and are a reliable measurement of chronic exposure. Dietary intake of AGE may be lower in vegetarian patients than in non-vegetarian patients, so we determined whether vegetarian patients had lower SAF than non-vegetarian patients. We measured SAF in 332 adult haemodialysis patients using a UV technique in a standardised manner. Information about patients' demographic data, laboratory results and current medicinal prescriptions was collected retrospectively from the hospital's computerised database. The mean patient age was 65·2 (SD 15·1) years, 64 % were men, 42 % were diabetic, and 66 % were Caucasian. The mean SAF was 3·26 (SD 0·95) arbitrary units (AU), and SAF was lower in vegetarians as compared to non-vegetarians (2·71 (SD 0·6) v. 3·31 (SD 0·97) AU, P= 0·002). SAF was negatively correlated on both univariate (r -0·17, P= 0·002) and multiple linear regression (β coefficient -0·39, 95 % CI -0·7, -0·07, P= 0·019). SAF, a marker of tissue AGE deposition, was reduced in vegetarian haemodialysis patients after correction for known confounders, which suggests that a vegetarian diet may reduce exposure to preformed dietary AGE. Dietary manipulation could potentially reduce tissue AGE and SAF as well as CVD risk, but further prospective studies are warranted to confirm the present findings.

  15. Altering plasma sodium concentration rapidly changes blood pressure during haemodialysis.

    PubMed

    Suckling, Rebecca J; Swift, Pauline A; He, Feng J; Markandu, Nirmala D; MacGregor, Graham A

    2013-08-01

    Plasma sodium is increased following each meal containing salt. There is an increasing interest in the effects of plasma sodium concentration, and it has been suggested that it may have direct effects on blood pressure (BP) and possibly influences endothelial function. Experimental increases of plasma sodium concentration rapidly raise BP even when extracellular volume falls. Ten patients with end-stage renal failure established on haemodialysis were studied during the first 2 h of dialysis without fluid removal during this period. They were randomized to receive haemodialysis with (i) dialysate sodium concentration prescribed to 135 mmol/L and (ii) 145 mmol/L in random order in a prospective, single-blinded crossover study. BP measurements and blood samples were taken every 30 min. Pre-dialysis sitting BP was 137/76 ± 7/3 mmHg. Lower dialysate sodium concentration (135 mmol/L) reduced plasma sodium concentration [139.49 ± 0.67 to 135.94 ± 0.52 mmol/L (P < 0.001)], whereas plasma sodium concentration was not altered by higher dialysate sodium (145 mmol/L) (140.17 ± 0.66 mmol/L at baseline to 140.72 ± 0.43 mmol/L at 120 min). Systolic BP was lower with dialysate sodium concentration 135 mmol/L [area under the curve (AUC) 15823.50 ± 777.15 (mmHg)min] compared with 145 mmol/L [AUC 17018.20 ± 1102.17 (mmHg)min], mean difference 1194.70 ± 488.41 (mmHg)min, P < 0.05. There was a significant positive relationship between change in plasma sodium concentration and change in systolic BP. This direct relationship suggests that a fall of 1 mmol/L in plasma sodium concentration would be associated with a 1.7 mmHg reduction in systolic BP (P < 0.05). The potential mechanism for the increase in BP seen with salt intake may be through small but significant changes in plasma sodium concentration.

  16. Outcomes of arteriovenous fistula creation, effect of preoperative vein mapping and predictors of fistula success in incident haemodialysis patients: A single-centre experience.

    PubMed

    Lee, Kian-Guan; Chong, Tze-Tec; Goh, Nicholette; Achudan, Shaam; Tan, Yi-Liang; Tan, Ru-Yu; Choong, Hui-Lin; Tan, Chieh-Suai

    2017-05-01

    Vascular access in haemodialysis is critical for effective therapy. We aim to evaluate the outcomes of arteriovenous fistula (AVF) creation in incident haemodialysis patients, impact of preoperative vein mapping and predictors of successful AVF maturation in our centre. Data of End-stage Renal Disease (ESRD) patients initiated on haemodialysis from January 2010 to December 2012 in our centre were retrospectively obtained from electronic medical records and clinical notes. Demographic characteristics, medical comorbidities, perioperative details were collected, and patients were followed up until 1 January 2014. A total of 708 patients (median age 64, IQR 55-72) were included with mean duration of follow up of 2.3 ± 1.2 years, with access of AVF and arteriovenous graft (AVG) in 694 (98%) and 14 (2%) patients respectively. Eight patients were lost to follow-up. Successful AVF maturation was achieved in 542 patients (78%), with 1-year cumulative patency rate of 74%. Multivariate analysis revealed male gender, upper arm AVF and good postoperative thrill and pulse as predictors of successful AVF maturation. Preoperative vein mapping was performed in 42.5% (295/694) of patients, with mean vein diameter of 2.44 ± 0.82 mm. Maturation rates with and without vein mapping were 72.2% and 82.4%, respectively, (P = 0.001). In patients with vein diameters of <2 mm and ≥2 mm, there was no statistically significant difference in maturation rates (71.3% vs. 72.6%; P = 0.887) and median maturation time (66 vs. 78 days; P = 0.73). Arteriovenous fistula can be successfully created in most incident haemodialysis patients. Routine vein mapping is not necessary if veins are suitable on physical examination alone, and vein sizes of <2 mm on ultrasound is not associated with lower AVF maturation rate. © 2016 Asian Pacific Society of Nephrology.

  17. Adherence with renal dosing recommendations in outpatients undergoing haemodialysis.

    PubMed

    Kim, G J; Je, N K; Kim, D-S; Lee, S

    2016-02-01

    Adjustment of drug dosage in patients with end-stage renal disease prevents serious adverse effects, which occur due to the accumulation of drugs or other toxic metabolites. Nevertheless, dosing errors occur most commonly among patients with end-stage renal disease. The aim of this study was to assess the quality of care for end-stage renal disease outpatients using their renal dosing adjustment status. A cross-sectional study was performed using the data collected from 43 South Korean medical institutions via questionnaires. A total of 2428 patients on haemodialysis, who were at least 18 years of age, were included. Among these patients, the study population was confined to patients who were taking medications and required renal dosing adjustments from three therapeutic classes: antihypertensives, antihyperglycaemics and lipid-modifying agents. The study population (n = 828) was prescribed a total of 1097 drug orders for the target drugs. Determination of appropriate dosage adjustment was based on GFR (glomerular filtration rate) using the Modification of Diet in Renal Disease revised 4-variable equation. The primary outcome was non-adherence to drug dosing requirements for end-stage renal disease patients with consideration to their renal function. Among the study population (n = 828), 469 haemodialysis patients were identified as having drug orders that were adherent to renal dosing recommendations. There were significant differences between the patient groups who received recommendation-adherent and non-adherent drug orders in the characteristics of the medical institutions they visited, causes of chronic renal failure and prevalence of concurrent diabetes mellitus. The primary factor of non-adherence to renal dosing adjustment recommendations was characteristics of medical institutions. Compared to tertiary hospitals, secondary hospitals and primary care clinics were 1·16 and 1·22 times, respectively, more non-adherent in accordance with the multivariate

  18. Correlation between the microinflammatory state and left ventricular structural and functional changes in maintenance haemodialysis patients

    PubMed Central

    SHI, LIHUA; SONG, JIE; ZHANG, XIAODONG; LI, YING; LI, HUI

    2013-01-01

    The aim of this study was to examine the correlation between the microinflammatory state and structural and functional changes of the left ventricle in maintenance haemodialysis patients (MHD). In total, 48 MHD patients and 30 healthy volunteers participated in this study. The microinflammatory state was detected from high-sensitivity C-reactive protein (hs-CRP), interleukin-6 (IL-6) and tumour necrosis factor-α (TNF-α) levels determined by ELISA. The structure and function of the left ventricle was measured according to ultrasound cardiogram examination. The serum levels of hs-CRP, IL-6 and TNF-α in the MHD patients were higher compared with those in the controls (P<0.05). Furthermore, the measurements of the left atrial diameter (LAD), left venticular diameter (LVD), interventricular septal thickness (IVST), left ventricular posterior wall thickness (LVPWT) and the left ventricular mass index (LVMI) increased significantly and the left ventricular function (LVEF) was reduced. Correlation analysis demonstrated that the concentrations of hs-CRP, TNF-α and IL-6 correlated with the LVMI (P<0.05), but only hs-CRP correlated with the loss of function of the heart in the haemodialysis patients (P<0.05). The microinflammatory state may be closely associated with the structural and functional impairment of the heart in MHD patients. PMID:24137221

  19. Improving compliance with iron infusion therapy in the treatment of chronic anemia in haemodialysis patients with chronic kidney disease.

    PubMed

    Nuti, Amith

    2015-01-01

    This quality improvement project was conducted at the haemodialysis unit in the paediatric nephrology department at Noah's Ark Children's Hospital, Cardiff. Stakeholders involved were the medical and nursing staff at the haemodialysis unit, responsible for the care of children with chronic kidney disease CKD. Anaemia is prevalent among children with CKD. Iron infusion is administered to such children with chronic anaemia. Children on haemodialysis attending the Children's Kidney Center receive iron infusion if they satisfy the criteria based on haemoglobin and serum ferritin values according to departmental guidelines. This involves measurement of c-reactive protein and serum ferritin prior to iron administration. High iron exposure is detrimental to end organ function and hence warrants regular monitoring in conjunction with CRP, another inflammatory marker. We suspect that some children may be receiving iron infusions despite being iron replete. Also, we may be over-investigating these children with anaemia. We identified all children receiving iron infusion in the haemodialysis unit over a four week period. We retrospectively enquired blood investigations done, prior to and after iron infusion. Blood investigations lagged on pre and post infusion times. We devised a checklist for nursing staff to follow, primarily looking at set times for measuring haemoglobin, serum ferritin, and CRP during the month (at the start of the first and third week of the month) and also tabulating the ferritin values that would trigger frequency of iron infusions. These were aimed to: 1. Prevent iron overloading in patients with chronic anemia 2. Regularise the checking of bloods in those receiving iron infusions 3. Empower the nursing staff to independently take decisions on iron infusion delivery. The strategy for change encompassed multiple PDSA cycles. Plan: empower decision making on iron infusion by haemodialysis nursing staff Do: formulate a checklist for iron infusion based

  20. Improving compliance with iron infusion therapy in the treatment of chronic anemia in haemodialysis patients with chronic kidney disease

    PubMed Central

    Nuti, Amith

    2015-01-01

    This quality improvement project was conducted at the haemodialysis unit in the paediatric nephrology department at Noah's Ark Children's Hospital, Cardiff. Stakeholders involved were the medical and nursing staff at the haemodialysis unit, responsible for the care of children with chronic kidney disease CKD. Anaemia is prevalent among children with CKD. Iron infusion is administered to such children with chronic anaemia. Children on haemodialysis attending the Children's Kidney Center receive iron infusion if they satisfy the criteria based on haemoglobin and serum ferritin values according to departmental guidelines. This involves measurement of c-reactive protein and serum ferritin prior to iron administration. High iron exposure is detrimental to end organ function and hence warrants regular monitoring in conjunction with CRP, another inflammatory marker. We suspect that some children may be receiving iron infusions despite being iron replete. Also, we may be over-investigating these children with anaemia. We identified all children receiving iron infusion in the haemodialysis unit over a four week period. We retrospectively enquired blood investigations done, prior to and after iron infusion. Blood investigations lagged on pre and post infusion times. We devised a checklist for nursing staff to follow, primarily looking at set times for measuring haemoglobin, serum ferritin, and CRP during the month (at the start of the first and third week of the month) and also tabulating the ferritin values that would trigger frequency of iron infusions. These were aimed to: 1. Prevent iron overloading in patients with chronic anemia 2. Regularise the checking of bloods in those receiving iron infusions 3. Empower the nursing staff to independently take decisions on iron infusion delivery. The strategy for change encompassed multiple PDSA cycles. Plan: empower decision making on iron infusion by haemodialysis nursing staff Do: formulate a checklist for iron infusion based

  1. Haemodialysis plastic cannulae - a possible alternative to traditional metal needles?

    PubMed

    Parisotto, Maria Teresa; Pelliccia, Francesco; Bedenbender-Stoll, Eva; Gallieni, Maurizio

    2016-09-21

    Haemodialysis plastic cannulae for arteriovenous fistulae (AVF) have been used for many years in Japan and recently this technique was introduced in Australia. Find answers to the following questions:What are the pros and cons of plastic cannulae versus traditional metal needles for AVF and arteriovenous graft (AVG)? Is the use of plastic cannulae instead of traditional metal needles an option for European dialysis units as well? If it is an option, for which patients should plastic cannulae be used? Literature search via PubMed and Google. Due to the characteristics of plastic cannulae, they seem to be well suited for restless patients, patients with unpredictable behaviour, children, and patients who are allergic to metal.However, the evidence base provided by studies on the use of cannulae is currently weak. More controlled randomised studies are needed.

  2. Tunnelled haemodialysis catheter and haemodialysis outcomes: a retrospective cohort study in Zagreb, Croatia.

    PubMed

    Pašara, Vedran; Maksimović, Bojana; Gunjača, Mihaela; Mihovilović, Karlo; Lončar, Andrea; Kudumija, Boris; Žabić, Igor; Knotek, Mladen

    2016-05-17

    Studies have reported that the tunnelled dialysis catheter (TDC) is associated with inferior haemodialysis (HD) patient survival, in comparison with arteriovenous fistula (AVF). Since many cofactors may also affect survival of HD patients, it is unclear whether the greater risk for survival arises from TDC per se, or from associated conditions. Therefore, the aim of this study was to determine, in a multivariate analysis, the long-term outcome of HD patients, with respect to vascular access (VA). Retrospective cohort study. This retrospective cohort study included all 156 patients with a TDC admitted at University Hospital Merkur, from 2010 to 2012. The control group consisted of 97 patients dialysed via AVF. The groups were matched according to dialysis unit and time of VA placement. The site of choice for the placement of the TDC was the right jugular vein. Kaplan-Meier analysis with log-rank test was used to assess patient survival. Multivariate Cox regression analysis was used to determine independent variables associated with patient survival. Patient survival with respect to VA. The cumulative 1-year survival of patients who were dialysed exclusively via TDC was 86.4% and of those who were dialysed exclusively via AVF, survival was 97.1% (p=0.002). In multivariate Cox regression analysis, male sex and older age were independently negatively associated with the survival of HD patients, while shorter HD vintage before the creation of the observed VA, hypertensive renal disease and glomerulonephritis were positively associated with survival. TDC was an independent risk factor for survival of HD patients (HR 23.0, 95% CI 6.2 to 85.3). TDC may be an independent negative risk factor for HD patient survival. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Central venous stenosis in haemodialysis patients without a previous history of catheter placement.

    PubMed

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-08-01

    To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.

  4. Dietary egg whites for phosphorus control in maintenance haemodialysis patients: a pilot study.

    PubMed

    Taylor, Lynn M; Kalantar-Zadeh, Kamyar; Markewich, Theodore; Colman, Sara; Benner, Debbie; Sim, John J; Kovesdy, Csaba P

    2011-03-01

    High dietary protein intake is associated with greater survival in maintenance haemodialysis (MHD) patients. High-protein foods may increase dietary phosphorus burden, which is associated with increased mortality in these patients. Hypothesis is: an egg white based diet with low phosphorus to protein ratio (<1.4 mg/g) will lower serum phosphorus without deteriorating the nutritional status in MHD patients. We assessed serum phosphorus and albumin levels in MHD patients who agreed to ingest one meal per day with pasteurised liquid egg whites without phosphorus additives, as principal protein source. Thirteen otherwise stable MHD patients with serum phosphorus >4.0 mg/dl agreed to consume eight ounces (225 g) of pasteurised liquid egg whites one meal per day for six weeks. Recipes were suggested to improve diet variety. Thirteen participating patients included seven women, three African Americans and five diabetics. Twelve patients exhibited drop in serum phosphorus. Mean population fall in serum phosphorus was 0.94 mg/dl, i.e. from 5.58 ± 1.34 (mean ± SD) to 4.63 ± 1.18 (p = 0.003). Serum albumin showed an increase by 0.19 g/dl, i.e. from 4.02 ± 0.29 to 4.21 ± 0.36 g/dl (p = 0.014). Changes in phosphorus pill count were not statistically significant (p = 0.88). The egg white diet was well tolerated, and recipe variety appreciated. Pasteurised liquid egg whites may be an effective diet component lowering serum phosphorus without risking malnutrition. Controlled trials are indicated to examine egg white based dietary interventions in MHD patients at home or during haemodialysis treatment. © 2011 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  5. A novel bioactive haemodialysis system using dissolved dihydrogen (H2) produced by water electrolysis: a clinical trial.

    PubMed

    Nakayama, Masaaki; Nakano, Hirofumi; Hamada, Hiromi; Itami, Noritomo; Nakazawa, Ryoichi; Ito, Sadayoshi

    2010-09-01

    Chronic inflammation in haemodialysis (HD) patients indicates a poor prognosis. However, therapeutic approaches are limited. Hydrogen gas (H(2)) ameliorates oxidative and inflammatory injuries to organs in animal models. We developed an HD system using a dialysis solution with high levels of dissolved H(2) and examined the clinical effects. Dialysis solution with H(2) (average of 48 ppb) was produced by mixing dialysate concentrates and reverse osmosis water containing dissolved H(2) generated by a water electrolysis technique. Subjects comprised 21 stable patients on standard HD who were switched to the test HD for 6 months at three sessions a week. During the study period, no adverse clinical signs or symptoms were observed. A significant decrease in systolic blood pressure (SBP) before and after dialysis was observed during the study, and a significant number of patients achieved SBP <140 mmHg after HD (baseline, 21%; 6 months, 62%; P < 0.05). Changes in dialysis parameters were minimal, while significant decreases in levels of plasma monocyte chemoattractant protein 1 (P < 0.01) and myeloperoxidase (P < 0.05) were identified. Adding H(2) to haemodialysis solutions ameliorated inflammatory reactions and improved BP control. This system could offer a novel therapeutic option for control of uraemia.

  6. The carbon footprint of an Australian satellite haemodialysis unit.

    PubMed

    Lim, Allan E K; Perkins, Anthony; Agar, John W M

    2013-06-01

    This study aimed to better understand the carbon emission impact of haemodialysis (HD) throughout Australia by determining its carbon footprint, the relative contributions of various sectors to this footprint, and how contributions from electricity and water consumption are affected by local factors. Activity data associated with HD provision at a 6-chair suburban satellite HD unit in Victoria in 2011 was collected and converted to a common measurement unit of tonnes of CO2 equivalents (t CO2-eq) via established emissions factors. For electricity and water consumption, emissions factors for other Australian locations were applied to assess the impact of local factors on these footprint contributors. In Victoria, the annual per-patient carbon footprint of satellite HD was calculated to be 10.2t CO2-eq. The largest contributors were pharmaceuticals (35.7%) and medical equipment (23.4%). Throughout Australia, the emissions percentage attributable to electricity consumption ranged from 5.2% to 18.6%, while the emissions percentage attributable to water use ranged from 4.0% to 11.6%. State-by-state contributions of energy and water use to the carbon footprint of satellite HD appear to vary significantly. Performing emissions planning and target setting at the state level may be more appropriate in the Australian context. What is known about the topic? Healthcare provision carries a significant environmental footprint. In particular, conventional HD uses substantial amounts of electricity and water. In the UK, provision of HD and peritoneal dialysis was found to have an annual per-patient carbon footprint of 7.1t CO2-eq. What does this paper add? This is the first carbon-footprinting study of HD in Australia. In Victoria, the annual per-patient carbon footprint of satellite conventional HD is 10.2t CO2-eq. Notably, the contributions of electricity and water consumption to the carbon footprint varies significantly throughout Australia when local factors are taken into

  7. Estimated dietary sodium intake in haemodialysis patients using food frequency questionnaires

    PubMed Central

    Gkza, Anastasia

    2017-01-01

    Abstract Background In clinical practice, dietary sodium assessment requires reliable and rapid screening tools. We wished to evaluate the usefulness of food frequency questionnaires (FFQ) in estimating dietary sodium intakes in haemodialysis patients. Methods We used the Derby Salt Questionnaire (DSQ), and Scored Sodium Questionnaire (SSQ) to estimate sodium intake. Body composition was determined by bioimpedance. Results In total, 139 haemodialysis patients (95 men) completed the FFQs, with mean ± standard deviation age 67 ± 15 years. The mean FFQ scores were DSQ 3.5 ± 2.0 and SSQ 68.4 ± 24.5. Men had higher estimated dietary sodium intakes [DSQ median (range) 3.6 (0.6–10.1) versus female 2.2 (0.5–9.1), P = 0.007)]. Younger patients and those aged >75 years had the higher SSQ dietary sodium scores; 70.7 ± 27.8 and 76.8 ± 24.6 versus those aged 55–75 years, 61.8 ± 22.3, P = 0.04. Patients with greater estimated sodium intake had higher extracellular water (ECW) to intracellular water (ICW) ratios pre-dialysis [75.1 ±12.5 versus 67.7 ± 4.8, P < 0.001] and ECW excess pre-dialysis [1.8 (1.5–2.6) versus 1.3 (0.8–2.0) L, P < 0.05]. Mean arterial pressure (MAP) and inter-dialytic weight gains did not differ; however, the fall in MAP during dialysis was lower in the higher estimated dietary sodium group (0.9 ± 13.7% versus 6.5 ± 14.1%, P = 0.04). Conclusions Both questionnaires were acceptable to patients and identified higher estimated dietary sodium intake for men, those with greater ECW and, somewhat surprisingly, we found that older patients had a greater dietary sodium intake than expected. PMID:28979785

  8. Estimated dietary sodium intake in haemodialysis patients using food frequency questionnaires.

    PubMed

    Gkza, Anastasia; Davenport, Andrew

    2017-10-01

    In clinical practice, dietary sodium assessment requires reliable and rapid screening tools. We wished to evaluate the usefulness of food frequency questionnaires (FFQ) in estimating dietary sodium intakes in haemodialysis patients. We used the Derby Salt Questionnaire (DSQ), and Scored Sodium Questionnaire (SSQ) to estimate sodium intake. Body composition was determined by bioimpedance. In total, 139 haemodialysis patients (95 men) completed the FFQs, with mean ± standard deviation age 67 ± 15 years. The mean FFQ scores were DSQ 3.5 ± 2.0 and SSQ 68.4 ± 24.5. Men had higher estimated dietary sodium intakes [DSQ median (range) 3.6 (0.6-10.1) versus female 2.2 (0.5-9.1), P = 0.007)]. Younger patients and those aged >75 years had the higher SSQ dietary sodium scores; 70.7 ± 27.8 and 76.8 ± 24.6 versus those aged 55-75 years, 61.8 ± 22.3, P = 0.04. Patients with greater estimated sodium intake had higher extracellular water (ECW) to intracellular water (ICW) ratios pre-dialysis [75.1 ±12.5 versus 67.7 ± 4.8, P < 0.001] and ECW excess pre-dialysis [1.8 (1.5-2.6) versus 1.3 (0.8-2.0) L, P < 0.05]. Mean arterial pressure (MAP) and inter-dialytic weight gains did not differ; however, the fall in MAP during dialysis was lower in the higher estimated dietary sodium group (0.9 ± 13.7% versus 6.5 ± 14.1%, P = 0.04). Both questionnaires were acceptable to patients and identified higher estimated dietary sodium intake for men, those with greater ECW and, somewhat surprisingly, we found that older patients had a greater dietary sodium intake than expected. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA.

  9. Novel Use of a Pneumatic Compression Device for Haemostasis of Haemodialysis Fistula Access Catheterisation Sites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O’Reilly, Michael K., E-mail: moreilly1@mater.ie; Ryan, David; Sugrue, Gavin

    PurposeTransradial pneumatic compression devices can be used to achieve haemostasis following radial artery puncture. This article describes a novel technique for acquiring haemostasis of arterio-venous haemodialysis fistula access sites without the need for suture placement using one such compression device.Materials and MethodsA retrospective review of fistulograms with or without angioplasty/thrombectomy in a single institution was performed. 20 procedures performed on 12 patients who underwent percutaneous intervention of failing or thrombosed arterio-venous fistulas (AVF) had 27 puncture sites. Haemostasis was achieved using a pneumatic compression device at all access sites. Procedure details including size of access sheath, heparin administration and complicationsmore » were recorded.ResultsTwo diagnostic fistulograms, 14 fistulograms and angioplasties and four thrombectomies were performed via access sheaths with an average size (±SD) of 6 Fr (±1.12). IV unfractionated heparin was administered in 11 of 20 procedures. Haemostasis was achieved in 26 of 27 access sites following 15–20 min of compression using the pneumatic compression device. One case experienced limited bleeding from an inflow access site that was successfully treated with reinflation of the device for a further 5 min. No other complication was recorded.ConclusionsHaemostasis of arterio-venous haemodialysis fistula access sites can be safely and effectively achieved using a pneumatic compression device. This is a technically simple, safe and sutureless technique for acquiring haemostasis after AVF intervention.« less

  10. The effect of the emotional intelligence education programme on quality of life in haemodialysis patients.

    PubMed

    Shahnavazi, Masoome; Parsa-Yekta, Zohreh; Yekaninejad, Mir-Saeed; Amaniyan, Sara; Griffiths, Pauline; Vaismoradi, Mojtaba

    2018-02-01

    This study investigated the effect of the emotional intelligence education programme on quality of life of haemodialysis patients. Nurses need knowledge development regarding the impact of educational strategies on patients' quality of life suffering from chronic diseases. A pragmatic quasi-randomized controlled trial was conducted with 47 haemodialysis patients attending a university hospital in an urban area of Iran. The patients were randomly assigned to intervention (n=23) and control (n=24) groups. A socio-demographic questionnaire, the Cyberia-Shrink Emotional Intelligence Questionnaire, and the Kidney Disease Quality of Life-Short Form were used to gather data. The intervention group attended an educational programme on emotional intelligence that consisted of six-group discussion sessions. To ensure the continuity of learning and to measure the subsequent expected behavioural changes, the patients filled out the data collection tools six and 12weeks after the completion of the education programme. The mean score of quality of life in the intervention group was 39.94±15.88 in pre-test, 44.87±16.04 six weeks and 52.47±16.07 at the 12weeks after the intervention (p=0.032). The consideration of emotional intelligence educational strategies by nurses requires its incorporation into pre-qualifying nursing degrees and professional development programmes. Nurse managers need to lead nurses for applying emotional intelligence in daily practice with the aim of providing an holistic patient care. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  11. Aspects of platelet disturbances in haemodialysis patients

    PubMed Central

    Schoorl, Marianne; Grooteman, Muriel P.C.; Bartels, Piet C.M.; Nubé, Menso J.

    2013-01-01

    Patients with mild-to-chronic kidney disease (CKD) exhibit a variety of haemostatic disorders, ranging from an increased clotting tendency and reductions in the levels of natural inhibitors of coagulation to defective fibrinolysis. In addition, platelet (PLT) abnormalities are common. In this minireview, we report on aspects of haemodialysis (HD)-induced PLT activation. It is demonstrated that PLTs from HD patients are exhausted due to repeated stimulation of HD treatment and recurrent release of PLT degranulation products. During HD, additional aberrations of the haemostatic process occur. Besides deviations of coagulation and fibrinolysis, PLT activation and a reduction in their granule content have been observed during HD treatment. As HD treatment is carried out three times per week, month after month, chronic HD patients may suffer persistently from coagulation defects and PLT disorders on top of the alterations induced by the uraemic state itself. PLT activation occurs together with thrombin and fibrin generation. However, macro fibrin depositions in clot devices are not demonstrated, microaggregates occur not only in the extracorporeal circuit (ECC) but are also present in the blood circulation. As vascular access thrombosis is a frequent complication in patients with HD treatment, it is believed that hypercoagulability could result from vascular changes combined with PLTs and activation of coagulation factors. PMID:24596657

  12. Specific balance training included in an endurance-resistance exercise program improves postural balance in elderly patients undergoing haemodialysis.

    PubMed

    Frih, Bechir; Mkacher, Wajdi; Jaafar, Hamdi; Frih, Ameur; Ben Salah, Zohra; El May, Mezry; Hammami, Mohamed

    2018-04-01

    The purpose of this study was to evaluate the effects of 6 months of specific balance training included in endurance-resistance program on postural balance in haemodialysis (HD) patients. Forty-nine male patients undergoing HD were randomly assigned to an intervention group (balance training included in an endurance-resistance training, n = 26) or a control group (resistance-endurance training only, n = 23). Postural control was assessed using six clinical tests; Timed Up and Go test, Tinetti Mobility Test, Berg Balance Scale, Unipodal Stance test, Mini-Balance Evaluation Systems Test and Activities Balance Confidence scale. All balance measures increased significantly after the period of rehabilitation training in the intervention group. Only the Timed Up and Go, Berg Balance Scale, Mini-Balance Evaluation Systems Test and Activities Balance Confidence scores were improved in the control group. The ranges of change in these tests were greater in the balance training group. In HD patients, specific balance training included in a usual endurance-resistance training program improves static and dynamic balance better than endurance-resistance training only. Implications for rehabilitation Rehabilitation using exercise in haemodialysis patients improved global mobility and functional abilities. Specific balance training included in usual endurance resistance training program could lead to improved static and dynamic balance.

  13. Differential effects of phosphate binders on pre-dialysis serum bicarbonate in end-stage kidney disease patients on maintenance haemodialysis

    PubMed Central

    2013-01-01

    Background Phosphate binders’ constituents have alkalotic or acidotic properties and may contribute to acid base balance in haemodialysis patients. This study aimed to investigate the differential effects of phosphate binders on pre-dialysis serum bicarbonate in End Stage Kidney Disease patients on maintenance haemodialysis. Methods Stable out-patients having satellite haemodialysis for at least 3 months were retrospectively studied for 18 months, excluding those with other medical causes for metabolic acidosis. Blood results were censored for inpatient episodes, at the time of death, renal transplant or dialysis modality change. Multivariable multilevel mixed-effects linear regression was used and five groups of phosphate binders were compared: Group A(Calcium (Ca) and/or Aluminium (Al) binders); B(Sevelamer hydrochloride (SH) alone); C(lanthanum carbonate (LC) alone); D(SH and Ca/Al), E(LC and Ca/Al). Results Of 320 patients, 292 were eligible for analysis with a mean follow-up of 15.54 (standard deviation, SD 3.98) months. Similar mean pre-dialysis serum levels of bicarbonate were observed at all 6 month-interval analyses. At 18th months, observed mean serum bicarbonate levels in mmol/L were Group B: 21.58 (SD 2.82, P<0.001), C: 23.29 (SD 2.80, P=0.02), D: 21.56 (SD 3.00, P<0.001), and E: 21.29 (SD 3.62, P=0.92) compared with Group A: 22.98 (SD 2.77). Mean serum bicarbonate was related to total SH dose in mmol/L: 22.34 (SD 2.56) for SH <2.5 g/day, 21.61 (SD 2.62) for SH 2.5-4.8 g/day, 21.04 (SD 3.31) for SH >4.8 g/day compared with 22.85 (SD 2.91) for non-users; P-trend<0.001. Conclusions Phosphate binders’ constituents may contribute to/protect against a predisposition to pre-dialysis metabolic acidosis. This may be dose dependant in patients taking Sevelamer Hydrochloride. PMID:24079654

  14. Job satisfaction, stress and burnout associated with haemodialysis nursing: a review of literature.

    PubMed

    Hayes, Bronwyn; Bonnet, Ann

    2010-12-01

    Job dissatisfaction, stress and burnout are linked to high rates of nurses leaving the profession, poor morale and poor patient outcomes. Haemodialysis (HD) nursing is uniquely characterised by the intense-prolonged interaction with patients who require complex technological care. A review of nine papers found that factors affecting job satisfaction were aspects of nursing care, organisational factors and length of time that a nurse has been working in nephrology nursing. Factors affecting job stress and burnout were due to interpersonal relationships with physicians, patient care activities, violence and abuse from patients, organisational factors and a lack of access to ongoing education. © 2010 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  15. Comparison of Kt/V and urea reduction ratio in measuring dialysis adequacy in paediatric haemodialysis in England.

    PubMed

    Dunne, Nina; Campbell, Malcolm; Fitzpatrick, Maggie; Callery, Peter

    2014-06-01

    The National Kidney Foundation-Dialysis Outcomes Quality Initiative (KDOQI) guidelines and the Renal Association recommend the use of either Kt/V or urea reduction ratio (URR) to measure haemodialysis adequacy. To determine the methods used to measure paediatric haemodialysis adequacy and to assess consistency between calculations of single pool Kt/V (spKt/V) and URR. A service evaluation was conducted to establish current practices in measuring dialysis adequacy. A prospective longitudinal study was conducted to compare spKt/V and URR. Thirty-two children were recruited consisting of 13 males and 19 females in five paediatric dialysis centres. Inconsistencies were reported of the method of post-urea sampling with 4 of the 10 centres using the KDOQI recommended sampling method. Five dialysis centres reported using URR and five reported using spKt/V. There were substantial differences between the two measures. Using URR suggested that up to 44% of children did not receive adequate dialysis, whereas measurement by spKt/V suggested no more than 6% of the same dialysis sessions were not adequate. One standard measure should be used to assess dialysis adequacy in paediatric centres in England. KDOQI guidelines were not consistently followed in obtaining a post-urea blood sample and this procedure should be standardised. © 2014 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  16. Economic evaluations of interventions to manage hyperphosphataemia in adult haemodialysis patients: A systematic review.

    PubMed

    Rizk, Rana; Hiligsmann, Mickaël; Karavetian, Mirey; Evers, Silvia Maa

    2016-03-01

    Managing hyperphosphataemia in haemodialysis patients is resource-intensive. A search for cost-effective interventions in this field is needed to inform decisions on the allocation of healthcare resources. NHSEED, MEDLINE, EMBASE and CINAHL were searched for full economic evaluations of hyperphosphataemia-managing interventions in adult haemodialysis patients, published between 2004 and 2014, in English, French, Dutch or German. Incremental cost-effectiveness ratios of the interventions were up-rated to 2013US$ using Purchasing Power Parity conversion rates and Consumer Price Indices. The quality of included studies was assessed using the Extended Consensus on Health Economic Criteria List. Twelve out of the 1681 retrieved records fulfilled the inclusion criteria. They reported only on one aspect of hyperphosphataemia management, which is the use of phosphate binders (calcium-based and calcium-free, in first-line and sequential use). No economic evaluations of other phosphorus-lowering interventions were found. The included articles derived from five countries and most of them were funded by pharmaceutical companies. The incremental cost-effectiveness ratios of phosphate binders ranged between US$11 461 and US$157 760 per quality-adjusted life-year gained. Calcium-based binders (especially calcium acetate) appear to be the optimal cost-effective first- and second-line therapy in prevalent patients, while the calcium-free binder, lanthanum carbonate, might provide good value for money, as second-line therapy, in incident patients. The studies' overall quality was suboptimal. Drawing firm conclusions was not possible due to the quality heterogeneity and inconsistent results. Future high-quality economic evaluations are needed to confirm the findings of this review and to address other interventions to manage hyperphosphataemia in this population. © 2015 Asian Pacific Society of Nephrology.

  17. Pharmacokinetics of amoxycillin and clavulanic acid in haemodialysis patients following intravenous administration of Augmentin.

    PubMed Central

    Davies, B E; Boon, R; Horton, R; Reubi, F C; Descoeudres, C E

    1988-01-01

    1. Serum concentrations of amoxycillin and clavulanic acid were measured in patients with end-stage renal disease (ESRD) following intravenous administration of 1.2 g Augmentin. Augmentin was administered on a non-dialysis day and 2 h prior to a 4 h dialysis session. 2. The mean values of total serum clearance, mean residence time, volume of distribution at steady state, and terminal half-life for amoxycillin on the non-dialysis day were 14.4 ml min-1, 19.2 h, 14.9 l and 13.6 h, respectively. 3. The mean values of dialysis clearance, total serum clearance during dialysis, fractional drug removal during haemodialysis and half-life during dialysis for amoxycillin were 77.1 ml min-1, 91.5 ml min-1, 0.64 and 2.30 h, respectively. 4. The mean values of total serum clearance, mean residence time, volume of distribution at steady state, and terminal half-life for clavulanic acid on the non-dialysis day were 43.6 ml min-1, 4.4 h, 11.0 l and 3.05 h, respectively. 5. The mean values of dialysis clearance, total serum clearance during dialysis, fractional drug removal during haemodialysis and half-life during dialysis for clavulanic acid were 92.8 ml min-1, 136 ml min-1, 0.65 and 1.19 h, respectively. 6. The total serum clearance on the non-dialysis day, which represents non-renal clearance, was lower than that in normal subjects for both amoxycillin and clavulanic acid. These data would suggest some degree of hepatic impairment in patients with ESRD.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:3190988

  18. Identification of the needs of haemodialysis patients using the concept of Maslow's hierarchy of needs.

    PubMed

    Bayoumi, Magda

    2012-03-01

    Along with basic survival and other clinical outcomes, patients' quality of life is an important indicator to reflect the needs of these patients. Human needs are classified in Maslow's hierarchy, where the most essential basic physiological need provides the base, and self actualisation is at the top of pyramid. The aim of this study is to identify the patients' needs who are on maintenance haemodialysis using concept of Maslow's hierarchy. The descriptive study was conducted in the dialysis unit of Suez Canal University Hospitals. The study included 50 patients attending the dialysis unit. The findings showed that the patients' highest need was for self-esteem (92.0%), whereas the lowest was for love and belonging (38.0%). Statistically significant relationships were revealed between the identified love and belonging needs and patients' age and the duration of dialysis (p = 0.008). The total needs score was lower with the longer duration of dialysis (59.6 ± 7.3), compared to those with a duration less than 24 months (65.7 ± 8.1), p = 0.02. Based on the main study findings it is concluded that haemodialysis patients' highest need was for self-esteem, and the lowest was for love and belonging. These needs increased with longer duration of dialysis. Nurses need to be aware of these findings in order to be able to supply the necessary support to help the patient regain his/her self-concept. © 2011 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  19. Erythropoiesis-stimulating agent dosing, haemoglobin and ferritin levels in UK haemodialysis patients 2005-13.

    PubMed

    Birnie, Kate; Caskey, Fergus; Ben-Shlomo, Yoav; Sterne, Jonathan A C; Gilg, Julie; Nitsch, Dorothea; Tomson, Charles

    2017-04-01

    Erythropoiesis-stimulating agents (ESAs) with intravenous iron supplementation are the main treatment for anaemia in patients with chronic kidney disease. Although observational studies suggest better outcomes for patients who achieve higher haemoglobin (Hb) levels, randomized controlled trials comparing higher and lower Hb targets have led to safety concerns over higher targets and to changes in treatment guidelines. Quarterly data from 2005 to 2013 were obtained on 28 936 haemodialysis patients from the UK Renal Registry. We examined trends in ESA use and average dose, Hb and ferritin values over time and Hb according to the UK Renal Association guideline range. The average ESA dose declined over time, with sharper decreases of epoetin seen towards the end of 2006 and from 2009. Average Hb for patients on ESAs was 114.1 g/L [95% confidence interval (CI) 113.7, 114.6] in the first quarter of 2005, which decreased to 109.6 g/L (95% CI 109.3, 109.9) by the end of 2013. Average serum ferritin was 353 µg/L (95% CI 345, 360) at the start of 2005, increasing to 386 µg/L (95% CI 380, 392) in the final quarter of 2013. The percentage of patients with Hb in the range of 100-120 g/L increased from 46.1 at the start of 2005 to 57.6 at the end of 2013. Anaemia management patterns for haemodialysis patients changed in the UK between 2005 and 2013. These patterns most likely reflect clinician response to emerging trial evidence and practice guidelines. Registries play an important role in continued observation of anaemia management and will monitor further changes as new evidence on optimal care emerges. © The Author 2016. Published by Oxford University Press on behalf of ERA-EDTA.

  20. Effectiveness of an educational intervention and physical exercise on the functional capacity of patients on haemodialysis.

    PubMed

    Molina-Robles, Esmeralda; Colomer-Codinachs, Marta; Roquet-Bohils, Marta; Chirveches-Pérez, Emilia; Ortiz-Jurado, Pep; Subirana-Casacuberta, Mireia

    To describe the impact of a standard hospital educational intervention including active physical exercises on personal well-being, functional capacity and knowledge of the benefits of prescribed physical activity for patients undergoing haemodialysis. An uncontrolled, quasi-experimental, before-and-after study with repeated measures of response variables at 4, 8 and 12 weeks after participating in an educational and physical exercise hospital intervention. It was performed at the Nephrology Unit at the Hospital Complex in Vic within september and december 2014. The patients' well-being, functional capacity and knowledge were assessed. Assessment tools: NOC nursing indicators, Barthel index scale, FAC Holden, Timed Get Up and Go test and Daniels scale. We included 68 (80.0%) patients and 58 (85.3%) completed, with a mean age of 70.16±13.5 years; 62.1% were males. After 12 weeks, the patients had better scores of personal well-being (2.33±1.2, 3.88±0.8), more autonomy to perform activities of daily living (Barthel: 92.8±12.8; 93.5±13.9), more muscle strength (Daniels Scale: 3.81±0.7, 4.19±0.6) and walked more briskly (Get Up and Go test: 14.98±8.5; 15.65±10.5). All of the score differences were statistically significant (P<05) except the Barthel Index. The standard educational intervention and active exercise performed at hospital level improved the personal well-being, knowledge and functional capacity of patients on haemodialysis. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  1. COGNITIVE-HD study: protocol of an observational study of neurocognitive functioning and association with clinical outcomes in adults with end-stage kidney disease treated with haemodialysis.

    PubMed

    Palmer, Suetonia C; Ruospo, Marinella; Barulli, Maria Rosaria; Iurillo, Annalisa; Saglimbene, Valeria; Natale, Patrizia; Gargano, Letizia; Murgo, Angelo M; Loy, Clement; van Zwieten, Anita; Wong, Germaine; Tortelli, Rosanna; Craig, Jonathan C; Johnson, David W; Tonelli, Marcello; Hegbrant, Jörgen; Wollheim, Charlotta; Logroscino, Giancarlo; Strippoli, G F M

    2015-12-09

    The prevalence of cognitive impairment may be increased in adults with end-stage kidney disease compared with the general population. However, the specific patterns of cognitive impairment and association of cognitive dysfunction with activities of daily living and clinical outcomes (including withdrawal from treatment) among haemodialysis patients remain incompletely understood. The COGNITIVE impairment in adults with end-stage kidney disease treated with HemoDialysis (COGNITIVE-HD) study aims to characterise the age-adjusted and education-adjusted patterns of cognitive impairment (using comprehensive testing for executive function, perceptual-motor function, language, learning and memory, and complex attention) in patients on haemodialysis and association with clinical outcomes. A prospective, longitudinal, cohort study of 750 adults with end-stage kidney disease treated with long-term haemodialysis has been recruited within haemodialysis centres in Italy (July 2013 to April 2014). Testing for neurocognitive function was carried out by a trained psychologist at baseline to assess cognitive functioning. The primary study factor is cognitive impairment and secondary study factors will be specific domains of cognitive function. The primary outcome will be total mortality. Secondary outcomes will be cause-specific mortality, major cardiovascular events, fatal and non-fatal myocardial infarction and stroke, institutionalisation, and withdrawal from treatment at 12 months. This protocol was approved before study conduct by the following responsible ethics committees: Catania (approval reference 186/BE; 26/09/2013), Agrigento (protocol numbers 61-62; 28/6/2013), USL Roma C (CE 39217; 24/6/2013), USL Roma F (protocol number 0041708; 23/7/2013), USL Latina (protocol number 20090/A001/2011; 12/7/2013), Trapani (protocol number 3413; 16/7/2013) and Brindisi (protocol number 40259; 6/6/2013). All participants have provided written and informed consent and can withdraw from

  2. Radiation protection issues of treating hyperthyroidism with 131 I in patients on haemodialysis.

    PubMed

    Homer, L; Smith, A H

    2002-03-01

    We report on the cases of two patients referred for 131I treatment of hyperthyroidism who were dependent on haemodialysis. Following 131I administration, all disposable lines and filters from dialysis were collected and measured for 131I radioactivity. The amount of 131I retained by the filters at the end of each successive dialysis session was found to decay with effective half-lives of 6.6+/-0.2 and 6.3+/-0.2 days. Dose rate measurements at 1m from the patients were recorded to find the effective half-life of the radioiodine clearance, which were found to be 6.9 and 7.1 days. From measured dose rates taken at 30 cm, the radiation hazard to ward staff involved in patient management was shown to be negligible.

  3. Psychosocial and cognitive factors associated with adherence to dietary and fluid restriction regimens by people on chronic haemodialysis.

    PubMed

    Sensky, T; Leger, C; Gilmour, S

    1996-01-01

    Failure by people on chronic haemodialysis to adhere adequately to dietary and fluid restrictions can have serious medical consequences. Numerous psychosocial factors possibly associated with adherence have been investigated in previous research. However, most previous studies have examined one or a few variables in isolation, and have tended to focus on sociodemographic variables not easily amenable to intervention. Much previous work has tended to ignore potential differences in adherence between male and female dialysands. Sociodemographic and psychosocial factors associated with adherence to dietary and fluid restrictions were investigated in 45 people on haemodialysis attending one renal unit, excluding those with a residual urine volume > 500 ml/day. Multiple regression analyses were used to estimate the contribution to adherence of a range of variables, including gender, age, duration of dialysis, affective disturbance, past psychiatric history, health locus of control, social adjustment and social supports. Adherence to diet (measured by predialysis serum potassium) and to fluid restriction (interdialysis weight gain) were not linked, and had different psychosocial correlates. Regression models of four different aspects of adherence revealed very distinct psychosocial correlates, with contributions to adherence from complex interactions between psychosocial and cognitive variables, notably gender, age, social adjustment, health locus of control, and depression. The findings cast doubt on the results of many previous studies which have used simple models of adherence. Adherence is likely to be influenced in a complex manner by multiple factors including age, gender, locus of control, social adjustment, and past psychiatric history.

  4. Erythropoiesis-stimulating agent dosing, haemoglobin and ferritin levels in UK haemodialysis patients 2005–13

    PubMed Central

    Caskey, Fergus; Ben-Shlomo, Yoav; Sterne, Jonathan A.C.; Gilg, Julie; Nitsch, Dorothea; Tomson, Charles

    2017-01-01

    ABSTRACT Background: Erythropoiesis-stimulating agents (ESAs) with intravenous iron supplementation are the main treatment for anaemia in patients with chronic kidney disease. Although observational studies suggest better outcomes for patients who achieve higher haemoglobin (Hb) levels, randomized controlled trials comparing higher and lower Hb targets have led to safety concerns over higher targets and to changes in treatment guidelines. Methods: Quarterly data from 2005 to 2013 were obtained on 28 936 haemodialysis patients from the UK Renal Registry. We examined trends in ESA use and average dose, Hb and ferritin values over time and Hb according to the UK Renal Association guideline range. Results: The average ESA dose declined over time, with sharper decreases of epoetin seen towards the end of 2006 and from 2009. Average Hb for patients on ESAs was 114.1 g/L [95% confidence interval (CI) 113.7, 114.6] in the first quarter of 2005, which decreased to 109.6 g/L (95% CI 109.3, 109.9) by the end of 2013. Average serum ferritin was 353 µg/L (95% CI 345, 360) at the start of 2005, increasing to 386 µg/L (95% CI 380, 392) in the final quarter of 2013. The percentage of patients with Hb in the range of 100–120 g/L increased from 46.1 at the start of 2005 to 57.6 at the end of 2013. Conclusions: Anaemia management patterns for haemodialysis patients changed in the UK between 2005 and 2013. These patterns most likely reflect clinician response to emerging trial evidence and practice guidelines. Registries play an important role in continued observation of anaemia management and will monitor further changes as new evidence on optimal care emerges. PMID:27190350

  5. High versus low dialysate sodium concentration in chronic haemodialysis patients: a systematic review of 23 studies.

    PubMed

    Basile, Carlo; Pisano, Anna; Lisi, Piero; Rossi, Luigi; Lomonte, Carlo; Bolignano, Davide

    2016-04-01

    It is the object of debate whether a low or high dialysate sodium concentration (DNa(+)) should be advocated in chronic haemodialysis patients. In this paper, we aimed at evaluating benefits and harms of different DNa(+) prescriptions through a systematic review of the available literature. MEDLINE and CENTRAL databases were searched for studies comparing low or high DNa(+) prescriptions. Outcomes of interest were mortality, blood pressure (BP), interdialytic weight gain (IDWG), plasma sodium, hospitalizations, use of anti-hypertensive agents and intradialytic complications. Twenty-three studies (76 635 subjects) were reviewed. There was high heterogeneity in the number of patients analysed, overall study quality, duration of follow-up, DNa(+) and even in the definition of 'high' or 'low' DNa(+). The only three studies looking at mortality were observational. The risk of death was related to the plasma-DNa(+) gradient, but was also shown to be confounded by indication from the dialysate sodium prescription itself. BP was not markedly affected by high or low DNa(+). Patients treated with higher DNa(+) had overall higher IDWG when compared with those with lower DNa(+). Three studies reported a significant increase in intra-dialytic hypotensive episodes in patients receiving low DNa(+). Data on hospitalizations and use of anti-hypertensive agents were sparse and inconclusive. There is currently no definite evidence proving the superiority of a low or high uniform DNa(+) on hard or surrogate endpoints in maintenance haemodialysis patients. Future trials adequately powered to evaluate the impact of different DNa(+) on mortality or other patient-centred outcomes are needed. © The Author 2015. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  6. Assessment of haemodialysis adequacy by ionic dialysance: intra-patient variability of delivered treatment.

    PubMed

    McIntyre, Christopher W; Lambie, Stewart H; Taal, Maarten W; Fluck, Richard J

    2003-03-01

    Adequate delivered dose of solute removal (as assessed by urea reduction and calculation of Kt/V) is an important determinant of clinical outcome in chronic haemodialysis (HD) patients. The requirement for multiple blood sampling and efforts taken to minimize the effects of rebound on post-treatment samples ensure Kt/V is measured only intermittently. On-line conductivity monitoring (using sodium flux as a surrogate for urea) allows the repeated non-invasive measurement of Kt/V on each HD treatment. We have studied the accuracy of this method of measuring Kt/V, and the variability of treatment dose delivered to individual patients. We prospectively studied 26 established chronic HD patients over 4 weeks (316 treatments). Patients were dialysed using Hospal Integra dialysis monitors, equipped with Diascan modules to measure Kt/V. Data were downloaded automatically to a central computer server. Urea reduction was measured (once a week) by a two-pool calculation using 30 min post-treatment sampling. Treatment time, Q(B) and modality were fully delivered in all treatments analysed (97% of total). Kt/V measured by ionic dialysance (Kt/V(ID)) correlated highly with that derived from measurement of urea reduction (R(2)=0.92, P<0.0001). Kt/V(ID) underestimated urea-based Kt/V by a mean of only 1.5% (95% CI 0.18-2.9%). Kt/V(ID) varied greatly within individual patients with a mean CV of 0.13+/-0.10 (95% CI 0.05-0.3). If a Kt/V(ID) of 1.0 is considered 'adequate', 55% of the patients had variations that would have potentially altered their status as being adequately or inadequately dialysed, as the range of Kt/V readings cross that point during the study period. In conclusion, Kt/V(ID) seems to be an accurate and readily obtained measure of adequacy. Substantial variation in Kt/V implies repeated measures (ideally for all treatments) are necessary to gain a true picture of the mean treatment dose being delivered to patients.

  7. Fatal outcomes among patients on maintenance haemodialysis in sub-Saharan Africa: a 10-year audit from the Douala General Hospital in Cameroon.

    PubMed

    Halle, Marie Patrice; Ashuntantang, Gloria; Kaze, Francois Folefack; Takongue, Christian; Kengne, Andre-Pascal

    2016-11-03

    End-Stage Renal disease (ESRD) is associated with increased morbidity and mortality. We assessed the occurrence, time-trend and determinants of fatal outcomes of haemodialysis-treated ESRD patients over a 10-year period in a major referral hospital in Cameroon. Medical records of ESRD patients who started chronic haemodialysis at the Douala General Hospital between 2002 and 2012 were reviewed. Baseline characteristics and fatal outcomes on dialysis were recorded. Accelerated-failure time and logistic regression models were used to investigate the determinants of death. A total of 661 patients with 436 (66 %) being men were included in the study. Mean age at dialysis initiation was 46.3 ± 14.7 years. The median [25 th -75 th percentiles] duration on dialysis was 187 [34-754] days. A total of 297 (44.9 %) deaths were recorded during follow-up with statistical difference over the years (p < 0.0001 for year by year variation) but not in a linear fashion (p = 0.508 for linear trend), similarly in men and women (p = 0.212 for gender*year interaction). The death rate at 12 months of follow-up was 26.8 % (n = 177), with again similar variations across years (p < 0.0001). In all, 34 % of deaths occurred within the first 120 days. Year of study and background nephropathies were the main determinants of mortality, with the combination of diabetes and hypertension conveying a 127 % (95 % CI: 40-267 %) higher risk of mortality, relative to hypertension alone. Mortality in dialysis is excessively high in this setting. Because most of these premature deaths are potentially preventable, additional efforts are needed to offset the risk and maximise the benefits from the ongoing investments of the government to defray the cost of haemodialysis. Potential actions include sensitisation of the population and healthcare practitioners, early detection and referral of individuals with CKD; and additional subsidies to support the cost of managing co

  8. Use of complementary and alternative medicine by patients with end-stage renal disease on haemodialysis in Trinidad: A descriptive study.

    PubMed

    Bahall, Mandreker

    2017-05-04

    Despite the paucity of scientific evidence, complementary and alternative medicine (CAM) is widely used for the prevention and treatment of illness, holistic care, and counteracting the adverse effects of conventional medicine (CM). This study investigates the use of CAM by patients with end-stage renal disease (ESRD) on haemodialysis. This quantitative study was conducted from November 1, 2014 to December 31, 2014 in the haemodialysis unit at San Fernando General Hospital (San Fernando, Trinidad). Face-to-face questionnaire-based interviews were held with101of 125 eligible patients (response rate, 80.5%) at the chairside during haemodialysis. The completed questionnaires were entered into a secure computer database. Data analysis included descriptive analysis, χ 2 tests, and binary logistic regression analysis. A minority of the patients were CAM users (n = 19; 18.8%). All 19 CAM users took medicinal herbs, 78.9% (n = 15) used spiritual therapy, and 10.5% (n = 2) used alternative systems. Medicinal tea (n = 15; 78.9%), garlic (Allium sativum) (n = 17; 73.7%), and ginger (Zingiber officinale roscoe) (n = 13; 68.4%) were the most commonly used medicinal herbs. Seven (36.8%) patients used Chinese herbal medicines and 3 (15.8%) patients used Aloe vera. All CAM users were willing to use CAM without supervision or monitoring by their doctors while receiving CM. The use of CAM could not be predicted by age, sex, ethnicity, education, religion, marital status, or employment. Nearly all (98%) patients were satisfied with CAM. More than one-third (36.8%) of patients did not disclose their use of CAM to their doctors, who were generally indifferent to such therapy. The use of CAM by patients with ESRD was relatively infrequent. All patients used medicinal herbs, most patients used spiritual therapy, and a minority of patients used alternative systems. Complementary and alternative medicine was primarily used for spiritual reasons and the likelihood of its use

  9. Brief cognitive behavioural intervention for depression and anxiety symptoms improves quality of life in chronic haemodialysis patients.

    PubMed

    Lerma, Abel; Perez-Grovas, Héctor; Bermudez, Luis; Peralta-Pedrero, María L; Robles-García, Rebeca; Lerma, Claudia

    2017-03-01

    Psychological treatment of depression in end-stage renal disease (ESRD) has focused on severely depressed patients. We designed and tested a brief (5 weeks) cognitive behavioural intervention (CBI) to reduce mild and moderate depression and anxiety symptoms in patients with ESRD. For the purpose of this study, a single-blind, randomized controlled design was used to compare patients with ESRD under haemodialysis treatment with and without the CBI. Depression and anxiety symptoms were screened in 152 subjects (18-60 years old, 84 male). Sixty participants (age 41.8 ± 14.7, 29 males) with mild or moderate scores of depression (Beck Depression Inventory) and anxiety (Beck Anxiety Inventory) were randomly assigned to CBI or the control group. CBI techniques consisted of positive self-reinforcement, deep breathing, muscle relaxation, and cognitive restructuring. Depression, anxiety, quality of life (QoL), and cognitive distortion scores were evaluated at baseline, after 5 weeks (end of treatment) and after 4-week follow-up. All scores were compared by ANOVA for repeated measures with post-hoc tests adjusted by Bonferroni's method (p < .05 was considered significant). At follow-up, depression, anxiety, and cognitive distortions had decreased, and QoL had increased in the intervention group, and there were no changes in the control group. Clinical utility was 33% for depression and 43% for anxiety. A brief CBI of 5 weeks is effective for decreasing mild or moderate depression and anxiety symptoms and improving QoL in ESRD haemodialysis patients. A brief, systematic and structured cognitive behavioural intervention (CBI) decreases anxiety and depression symptoms and improves quality of life in patients with end-stage renal disease (ESRD) who are being treated with haemodialysis. These benefits are not achieved when anxiety and depression symptoms are identified but not treated psychologically. This CBI consisted of cognitive restructuring of the distorted thoughts

  10. Ultrasound-Guided Angioplasty of Dysfunctional Vascular Access for Haemodialysis. The Pros and Cons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    García-Medina, J., E-mail: josegmedina57@gmail.com; García-Alfonso, J. J., E-mail: juanjozarandieta@gmail.com

    PurposeTo describe the benefits and the disadvantages of angioplasty in dialysis fistulas using only ultrasound guidance.Materials and MethodsThis is a prospective study in 132 failing or non-maturing arteriovenous accesses that underwent 189 ultrasound-guided balloon angioplasties. The technical success was defined as non-use of X-ray fluoroscopy during the procedure.Results127 procedures (67%) were successfully completed without fluoroscopy. Most failures were due to difficulty to traverse aneurismal segments, as well as anastomotic stenoses. Including initial failures, the primary patency rates at 6, 12 months and 2 years were 75 ± 3, 41 ± 3 and 14 ± 2%, respectively.ConclusionEndovascular repair of the dysfunctional vascular access for haemodialysis under ultrasound guidance ismore » feasible and safe in roughly two-thirds of cases.« less

  11. Evidence of improved fluid management in patients receiving haemodialysis following a self-affirmation theory-based intervention: A randomised controlled trial.

    PubMed

    Wileman, Vari; Chilcot, Joseph; Armitage, Christopher J; Farrington, Ken; Wellsted, David M; Norton, Sam; Davenport, Andrew; Franklin, Gail; Da Silva Gane, Maria; Horne, Robert; Almond, Mike

    2016-01-01

    Haemodialysis patients are at risk of serious health complications; yet, treatment non-adherence remains high. Warnings about health risks associated with non-adherence may trigger defensive reactions. We studied whether an intervention based on self-affirmation theory reduced resistance to health-risk information and improved fluid treatment adherence. In a cluster randomised controlled trial, 91 patients either self-affirmed or completed a matched control task before reading about the health-risks associated with inadequate fluid control. Patients' perceptions of the health-risk information, intention and self-efficacy to control fluid were assessed immediately after presentation of health-risk information. Interdialytic weight gain (IDWG), excess fluid removed during haemodialysis, is a clinical measure of fluid treatment adherence. IDWG data were collected up to 12 months post-intervention. Self-affirmed patients had significantly reduced IDWG levels over 12 months. However, contrary to predictions derived from self-affirmation theory, self-affirmed participants and controls did not differ in their evaluation of the health-risk information, intention to control fluid or self-efficacy. A low-cost, high-reach health intervention based on self-affirmation theory was shown to reduce IDWG over a 12-month period, but the mechanism by which this apparent behaviour change occurred is uncertain. Further work is still required to identify mediators of the observed effects.

  12. Haemodialysis or haemodiafiltration: that is the question.

    PubMed

    Locatelli, Francesco; Carfagna, Fabio; Del Vecchio, Lucia; La Milia, Vincenzo

    2018-04-24

    Despite the technological and pharmacological advancements in the last 30 years, morbidity and mortality of dialysis patients are still astonishingly high. Today, convective treatments, such as high-flux haemodialysis (hf-HD) and haemodiafiltration (HDF), are established techniques; the online production of fresh pure dialysate has provided clinical and economic advantages. Nevertheless, the actual benefits of HDF, even with high-convective-volume treatments, are still debatable. Three recent, randomized controlled trials compared survival outcomes in prevalent patients receiving conventional HD or post-dilution HDF and reported conflicting results. The meta-analyses of the published trials were ultimately incapable of providing a clear and definitive answer on the possible beneficial effects of choosing one treatment over the other. All-cause mortality, anaemia, phosphate control and clearance of small molecules seemed to be unaffected by the treatment modality. On the other hand, cardiovascular mortality, intradialytic vascular stability and the clearance of protein-bound molecules fared better in patients treated with HDF. These results were not consistent between the studies. Thus, there is still no conclusive answer to the question that nephrologists would like to have answered: 'Which is the best treatment for my patient?' In the age of evidence-based medicine, we need strong data to support the superiority of a treatment in comparison with another, although theoretically plausible. There is the need for a well-designed clinical trial comparing outcomes for patients randomly assigned to high- or moderate-convection-volume HDF versus hf-HD to clearly prove the clinical superiority of HDF, including the effect of different infusion volumes.

  13. Multipass haemodialysis: a novel dialysis modality

    PubMed Central

    Heaf, James Goya; Axelsen, Mette; Pedersen, Robert Smith

    2013-01-01

    Introduction Most home haemodialysis (HD) modalities are limited to home use since they are based on a single-pass (SP) technique, which requires preparation of large amounts of dialysate. We present a new dialysis method, which requires minimal dialysate volumes, continuously recycled during treatment [multipass HD (MPHD)]. Theoretical calculations suggest that MPHD performed six times weekly for 8 h/night, using a dialysate bath containing 50% of the calculated body water, will achieve urea clearances equivalent to conventional HD 4 h thrice weekly, and a substantial clearance of higher middle molecules. Methods Ten stable HD patients were dialyzed for 4 h using standard SPHD (dialysate flow 500 mL/min). Used dialysate was collected. One week later, an 8-h MPHD was performed. The dialysate volume was 50% of the calculated water volume, the dialysate inflow 500 mL/min−0.5 × ultrafiltration/min and the outflow 500 mL/min + 0.5 × ultrafiltration/min. Elimination rates of urea, creatinine, uric acid, phosphate and β2-microglobulin (B2M) and dialysate saturation were determined hourly. Results Three hours of MPHD removed 49, 54, 50, 51 and 57%, respectively, of the amounts of urea, creatinine, uric acid, phosphate and B2M that were removed by 4 h conventional HD. The corresponding figures after 8 h MPHD were 63, 78, 74, 78 and 111%. Conclusions Clearance of small molecules using MPHD 6 × 8 h/week will exceed traditional HD 3 × 4 h/week. Similarly, clearance of large molecules will significantly exceed traditional HD and HD 5 × 2.5 h/week. This modality will increase patients' freedom of movement compared with traditional home HD. The new method can also be used in the intensive care unit and for automated peritoneal dialysis. PMID:23136214

  14. Psychosocial factors and adherence to drug treatment in patients on chronic haemodialysis.

    PubMed

    Huertas-Vieco, María P; Pérez-García, Rafael; Albalate, Marta; de Sequera, Patricia; Ortega, Mayra; Puerta, Marta; Corchete, Elena; Alcázar, Roberto

    2014-11-17

    The daily pill burden in hemodialysis patients is one of the highest reported to date in any chronic disease. The adherence to prescribed treatment has implications on the quality of life, the survival of patients, and the economic cost of their treatment, this being a priority public health issue. To evaluate the adherence to pharmacological treatment examining, among the possible causes of non-adherence, psychosocial factors such as depression, anxiety, cognitive impairment and social support. Transversal-observational study of thirty five patients that suffer from chronic renal disease and who are on manteinance hemodialysis, evaluated by self-reported measures. Non-adherent patients have significant higher depression index than adherent patients. Anxiety, cognitive impairment and social support do not show a significant relation with the degree of adherence or compliance with farmacological treatment. These results suggest that psychological intervention in chronic haemodialysis patients with a severe depression index could increase the degree of fulfillment and general well-being of renal patients.

  15. CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk

    PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNomore » immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.« less

  16. The Cost-Effectiveness of Continuous Erythropoiesis Receptor Activator Once Monthly versus Epoetin Thrice Weekly for Anaemia Management in Chronic Haemodialysis Patients

    PubMed Central

    Maoujoud, Omar; Ahid, Samir; Dkhissi, Hocein; Oualim, Zouhair; Cherrah, Yahia

    2015-01-01

    Introduction. The aim of this study was to compare the cost-effectiveness of continuous erythropoietin receptor activator (CERA) once monthly to epoetin beta (EpoB) thrice weekly to maintain haemoglobin (Hb) within the range 10.5–12 g/dL. Methods. Prospective cohort study and cost-effectiveness analysis. Chronic haemodialysis patients (CHP), being treated with EpoB, were selected for two periods of follow-up: period 1, maintaining prior treatment with EpoB, and period 2, conversion to CERA once monthly. Hb concentrations and costs were measured monthly. Health care payer perspective for one year was adopted. Results. 75 CHP completed the study, with a mean age of 52.9 ± 14.3 years. Baseline Hb was 11.14 ± 1.18 g/dL in EpoB phase and 11.46 ± 0.79 g/dL in CERA phase; we observed a significant increase in the proportion of patients successfully treated (Hb within the recommended range), 65.3% versus 70.7%, p: 0.008, and in the average effectiveness by 4% (0.55 versus 0.59). Average cost-effectiveness ratios were 6013.86 and 5173.64$, with an ICER CERA to EpoB at −6457.5$. Conclusion. Our health economic evaluation of ESA use in haemodialysis patients suggests that the use of CERA is cost-effective compared with EpoB. PMID:26843983

  17. Eco-dialysis: the financial and ecological costs of dialysis waste products: is a 'cradle-to-cradle' model feasible for planet-friendly haemodialysis waste management?

    PubMed

    Piccoli, Giorgina Barbara; Nazha, Marta; Ferraresi, Martina; Vigotti, Federica Neve; Pereno, Amina; Barbero, Silvia

    2015-06-01

    Approximately 2 million chronic haemodialysis patients produce over 2,000,000 tons of waste per year that includes about 600,000 tons of potentially hazardous waste. The aim of the present study was to analyse the characteristics of the waste that is produced through chronic haemodialysis in an effort to identify strategies to reduce its environmental and financial impact. The study included three dialysis machines and disposables for bicarbonate dialysis, haemodiafiltration (HFR) and lactate dialysis. Hazardous waste is defined as waste that comes into contact with bodily fluids. The weight and cost of waste management was evaluated by various policies of differentiation, ranging from a careful-optimal differentiation to a careless one. The amount of time needed for optimal management was recorded in 30 dialysis sessions. Non-hazardous materials were assessed for potential recycling. The amount of plastic waste that is produced per dialysis session ranges from 1.5 to 8 kg (from 1.1 to 8 kg of potentially hazardous waste), depending upon the type of dialysis machine and supplies, differentiation and emptying policies. The financial cost of waste disposal is high, and is mainly related to hazardous waste disposal, with costs ranging from 2.2 to 16 Euro per session (2.7-21 USD) depending on the waste management policy. The average amount of time needed for careful, optimal differentiation disposal is approximately 1 minute for a haemodialysis session and 2 minutes for HFR. The ecological cost is likewise high: less than one-third of non-hazardous waste (23-28%) is potentially recyclable, while the use of different types of plastic, glues, inks and labels prevents the remaining materials from being recycled. Acknowledging the problem of waste management in dialysis could lead to savings of hundreds of millions of Dollars and to the reuse and recycling of hundreds of tons of plastic waste per year on a world-wide scale with considerable financial and ecological savings

  18. Body composition analysis and adipocytokine concentrations in haemodialysis patients: abdominal fat gain as an additional cardiovascular risk factor.

    PubMed

    González, Elena; Díez, Juan J; Pérez Torres, Almudena; Bajo, María Auxiliadora; Del Peso, Gloria; Sánchez-Villanueva, Rafael; Grande, Cristina; Rodríguez, Olaia; Coronado, Mónica; Gómez Candela, Carmen; Díaz-Almirón, Mariana; Iglesias, Pedro; Selgas, Rafael

    Abdominal fat and its increment over time in particular has become a cardiovascular risk factor in uraemic patients. To analyse changes in abdominal fat in haemodialysis patients over one year and study their possible correlation with the variation in adipocytokine serum levels. As a secondary objective, we tried to validate the data obtained by bioelectrical impedance analysis (BIA) with data obtained by dual X-ray absorptiometry (DXA). A prospective one-year study was performed in 18 patients on haemodialysis (HD). In each patient, body composition by BIA and DXA was estimated at baseline and after one year. Several adipocytokine and biochemical parameters were determined. A significant increase in phase angle [4.8° (4.1-5.6) vs. 5.2° (4.4-5.8), P<.05], BIA intracellular water [48.3% (43.1-52.3) vs. 50.3% (45.7-53.4), P<.05] and the ratio between the percentage of android/gynecoid (A/G) distribution of fat measured by DXA [1.00 (0.80-1.26) vs. 1.02 (0.91-1.30), P<.05] was observed. A statistically significant relationship between leptin and adiponectin concentrations and the percentage of fat mass measured by BIA, as well as the abdominal fat percentage estimated by DXA, was found (P<.01). HD patients exhibit a gain in fat mass over time, especially in the abdomen, evidenced by an increased A/G ratio. These findings might explain the increased cardiovascular risk in these patients. Copyright © 2016 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  19. Prevalence of intradialytic hypotension, clinical symptoms and nursing interventions--a three-months, prospective study of 3818 haemodialysis sessions.

    PubMed

    Kuipers, Johanna; Oosterhuis, Jurjen K; Krijnen, Wim P; Dasselaar, Judith J; Gaillard, Carlo A J M; Westerhuis, Ralf; Franssen, Casper F M

    2016-02-27

    Intradialytic hypotension (IDH) is considered one of the most frequent complications of haemodialysis with an estimated prevalence of 20-50 %, but studies investigating its exact prevalence are scarce. A complicating factor is that several definitions of IDH are used. The goal of this study was, to assess the prevalence of IDH, primarily in reference to the European Best Practice Guideline (EBPG) on haemodynamic instability: A decrease in systolic blood pressure (SBP) ≥20 mmHg or in mean arterial pressure (MAP) ≥10 mmHg associated with a clinical event and the need for nursing intervention. During 3 months we prospectively collected haemodynamic data, clinical events, and nursing interventions of 3818 haemodialysis sessions from 124 prevalent patients who dialyzed with constant ultrafiltration rate and dialysate conductivity. Patients were considered as having frequent IDH if it occurred in >20 % of dialysis sessions. Decreases in SBP ≥20 mmHg or MAP ≥10 mmHg occurred in 77.7 %, clinical symptoms occurred in 21.4 %, and nursing interventions were performed in 8.5 % of dialysis sessions. Dialysis hypotension according to the full EBPG definition occurred in only 6.7 % of dialysis sessions. Eight percent of patients had frequent IDH. The prevalence of IDH according to the EBPG definition is low. The dominant determinant of the EBPG definition was nursing intervention since this was the component with the lowest prevalence. IDH seems to be less common than indicated in the literature but a proper comparison with previous studies is complicated by the lack of a uniform definition.

  20. Massive haematuria successfully managed by intravesical ankaferd in a haemodialysis patient complicated with disseminated intravascular coagulation

    PubMed Central

    Solak, Yalcin; Gaipov, Abduzhappar; Ozbek, Orhan; Hassan, Mustafa Aziz; Yeksan, Mehdi

    2012-01-01

    Massive haematuria is a life-threatening condition, demanding immediate management of bleeding. The mortality is very high in the case of delayed management of bleeding, especially in elderly patients with concomitant comorbidity. The treatment options of haematuria are wide, and depend on underlying conditions. However, therapeutic choices are limited in the presence of massive and intractable haematuria caused by disseminated intravascular coagulation (DIC). Ankaferd blood stopper (ABS) is a novel, commercially available, haemostatic agent, which has been approved by the Ministry of Health for local use in Turkey. Here, for the first time in the literature, we report a case of diffuse intravesical bleeding stopped by intravesical use of ABS in a 72-year-old man, haemodialysis patient complicated with sepsis and DIC. PMID:23266773

  1. Cognitive-behavioural therapy (CBT) for renal fatigue (BReF): a feasibility randomised-controlled trial of CBT for the management of fatigue in haemodialysis (HD) patients.

    PubMed

    Picariello, Federica; Moss-Morris, Rona; Macdougall, Iain C; Norton, Sam; Da Silva-Gane, Maria; Farrington, Ken; Clayton, Hope; Chilcot, Joseph

    2018-03-08

    Fatigue is one of the most common and disabling symptoms in end-stage kidney disease, particularly among in-centre haemodialysis patients. This two-arm parallel group feasibility randomised controlled trial will determine whether a fully powered efficacy trial is achievable by examining the feasibility of recruitment, acceptability and potential benefits of a cognitive-behavioural therapy (CBT)-based intervention for fatigue among in-centre haemodialysis patients. We aim to recruit 40 adult patients undergoing in-centre haemodialysis at secondary care outpatient dialysis units, who meet clinical levels of fatigue. Patients will be randomised individually (using a 1:1 ratio) to either a 4-6 weeks' CBT-based intervention (intervention arm) or to a waiting-list control (control arm). The primary feasibility outcomes include descriptive data on numbers within each recruiting centre meeting eligibility criteria, rates of recruitment, numbers retained postrandomisation and treatment adherence. To assess the potential benefits of the cognitive-behavioural therapy for renal fatigue intervention, secondary self-report outcomes include measures of fatigue severity (Chalder Fatigue Questionnaire), fatigue-related functional impairment (Work and Social Adjustment Scale), sleep quality (Pittsburgh Sleep Quality Index), depression (Patient Health Questionnaire-9) and anxiety (Generalised Anxiety Disorder-7). Changes in fatigue perceptions (Brief Illness Perception Questionnaire), cognitive and behavioural responses to fatigue (Cognitive and Behavioural Responses to Symptoms Questionnaire), sleep hygiene behaviours (Sleep Hygiene Index) and physical activity (International Physical Activity Questionnaire-short form) will also be explored. These self-report measures will be collected at baseline and 3 months postrandomisation. Nested qualitative interviews will be conducted postintervention to explore the acceptability of the intervention and identify any areas in need of

  2. Cognitive-behavioural therapy (CBT) for renal fatigue (BReF): a feasibility randomised-controlled trial of CBT for the management of fatigue in haemodialysis (HD) patients

    PubMed Central

    Moss-Morris, Rona; Macdougall, Iain C; Da Silva-Gane, Maria; Farrington, Ken; Clayton, Hope; Chilcot, Joseph

    2018-01-01

    Introduction Fatigue is one of the most common and disabling symptoms in end-stage kidney disease, particularly among in-centre haemodialysis patients. This two-arm parallel group feasibility randomised controlled trial will determine whether a fully powered efficacy trial is achievable by examining the feasibility of recruitment, acceptability and potential benefits of a cognitive-behavioural therapy (CBT)-based intervention for fatigue among in-centre haemodialysis patients. Methods We aim to recruit 40 adult patients undergoing in-centre haemodialysis at secondary care outpatient dialysis units, who meet clinical levels of fatigue. Patients will be randomised individually (using a 1:1 ratio) to either a 4–6 weeks’ CBT-based intervention (intervention arm) or to a waiting-list control (control arm). The primary feasibility outcomes include descriptive data on numbers within each recruiting centre meeting eligibility criteria, rates of recruitment, numbers retained postrandomisation and treatment adherence. To assess the potential benefits of the cognitive-behavioural therapy for renal fatigue intervention, secondary self-report outcomes include measures of fatigue severity (Chalder Fatigue Questionnaire), fatigue-related functional impairment (Work and Social Adjustment Scale), sleep quality (Pittsburgh Sleep Quality Index), depression (Patient Health Questionnaire-9) and anxiety (Generalised Anxiety Disorder-7). Changes in fatigue perceptions (Brief Illness Perception Questionnaire), cognitive and behavioural responses to fatigue (Cognitive and Behavioural Responses to Symptoms Questionnaire), sleep hygiene behaviours (Sleep Hygiene Index) and physical activity (International Physical Activity Questionnaire–short form) will also be explored. These self-report measures will be collected at baseline and 3 months postrandomisation. Nested qualitative interviews will be conducted postintervention to explore the acceptability of the intervention and identify

  3. Risk factors associated with xerostomia in haemodialysis patients.

    PubMed

    López-Pintor, R-M; López-Pintor, L; Casañas, E; de Arriba, L; Hernández, G

    2017-03-01

    To determine the prevalence of xerostomia and hyposalivation in Haemodialysis (HD) patients, to clarify risk factors, assess patient's quality of life, and to establish a possible correlation among interdialytic weight gain (IDWG) and xerostomia. This study was performed on a group of 50 HD patients. Data were collected using a questionnaire containing demographic and clinical variables, a visual analogue scale (VAS) for xerostomia, IDWG, and an oral health impact profile questionnaire (OHIP-14). Unstimulated whole saliva (UWS) and stimulated whole saliva (SWS) were collected. A total of 28 HD patients (56%) suffered xerostomia. Dry mouth was associated with hypertension (OR, 5.24; 95% CI, 1.11-24.89) and benzodiazepine consumption (OR, 5.96; 95% CI, 1.05-33.99). The mean xerostomia VAS and OHIP-14 scores were 31.74±14.88 and 24.38±11.98, respectively. No significant correlation was observed between IDWG% and VAS and OHIP total score. Nonetheless, a positive correlation between VAS level of thirst and IDWG% was found (r=0.48 p=0.0001). UWS and SWS means (determined in 30 patients) were 0.16±0.17 and 1.12±0.64, respectively. Decreased values of UWS and SWS were reported in 53.33% and 36.66% of HD patients. Xerostomia in HD has a multifactorial aetiology due to accumulative risks as advanced age, systemic disorders, drugs, fluid intake restriction, and salivary parenchymal fibrosis and atrophy. Therefore, it is important to detect possible xerostomia risk factors to treat correctly dry mouth in HD patients and avoid systemic complications.

  4. Lipoprotein(a) concentrations, apolipoprotein(a) isoforms and clinical endpoints in haemodialysis patients with type 2 diabetes mellitus: results from the 4D Study.

    PubMed

    Kollerits, Barbara; Drechsler, Christiane; Krane, Vera; Lamina, Claudia; März, Winfried; Dieplinger, Hans; Ritz, Eberhard; Wanner, Christoph; Kronenberg, Florian

    2016-11-01

    High lipoprotein(a) [Lp(a)] concentrations and low molecular weight (LMW) apolipoprotein(a) [apo(a)] isoforms are associated with cardiovascular disease and mortality in the general population. We examined the association of both with all-cause mortality and cardiovascular endpoints in haemodialysis patients with diabetes mellitus. This is a post hoc analysis of the prospective 4D Study (German Diabetes Dialysis Study) that evaluated atorvastatin compared with placebo in 1255 haemodialysis patients with type 2 diabetes mellitus (median follow-up 4 years). The association of natural logarithm-transformed Lp(a) concentrations (increment one unit) and apo(a) isoforms with outcomes was analysed by Cox proportional hazards regression. The influence of age (median 66 years) was evaluated by stratified survival analyses. The median baseline Lp(a) concentration was 11.5 mg/dL (IQR 5.0-41.8). A quarter of patients had at least one LMW apo(a) isoform. Increased Lp(a) concentrations were associated with all-cause mortality in the total group [hazard ratio (HR) 1.09 (95% CI 1.03-1.16), P = 0.004]. LMW apo(a) isoforms were only associated with all-cause mortality in patients ≤ 66 years [HR 1.38 (95% CI 1.05-1.80), P = 0.02]. The strongest association for Lp(a) concentrations and LMW apo(a) isoforms was found for death due to infection in patients ≤ 66 years [HR 1.39 (95% CI 1.14-1.71), P = 0.001; HR 2.17 (95% CI 1.26-3.75), P = 0.005]. Lp(a) concentrations were also associated with fatal stroke in patients ≤66 years of age [HR 1.54 (95% CI 1.05-2.24), P = 0.03]. Neither Lp(a) nor LMW apo(a) isoforms were associated with other atherosclerosis-related events. High Lp(a) concentrations and LMW apo(a) isoforms are risk predictors for all-cause mortality and death due to infection in haemodialysis patients with diabetes mellitus. These associations are modified by age. © The Author 2016. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  5. Nutritional status of vegetarians on maintenance haemodialysis.

    PubMed

    Wu, Tai-Te; Chang, Chieh-Ying; Hsu, Wei-Min; Wang, I-Kwan; Hsu, Chih-Hao; Cheng, Shu-Hwa; Liang, Chih-Chia; Chang, Chiz-Tzung; Huang, Chiu-Ching

    2011-08-01

    Vegetarian diets have long been thought of as beneficial to health. However, vegetarian diets are often low in protein, which is contradictory to the high protein diet guideline for uraemia patients. The purpose of the study was to investigate the impact of a vegetarian diet on the nutritional status of haemodialysis (HD) patients. Patients on chronic HD for over 6 months were included in the study. The normalized protein catabolic rate (nPCR) was used to reflect daily protein intake. Biochemical markers of nutrition, anthropometric parameters, subjective global assessment (SGA) and functional activity of daily living were assessed to evaluate the nutritional status of vegetarians on chronic HD. Nineteen out of 318 HD patients were vegetarians. The nPCR was lower in the vegetarian group (1.20 ± 0.24 vs 1.10 ± 0.29 g/kg per day, non-Veg vs Veg, P < 0.05). The serum albumin and prealbumin were similar in vegetarian and non-vegetarian HD patients. The body mass index (BMI) and mid-arm muscular circumference (MAMC) were lower in vegetarian patients (P < 0.05). The haematocrit of vegetarians can be maintained at a level similar to that of non-vegetarian patients but erythropoietin doses needed were higher in vegetarian patients (P < 0.05). The muscle strength evaluated by the hand-grip test, SGA and activities of daily living were similar in vegetarians and non-vegetarians. The present study revealed that HD patients on vegetarian diets might have a smaller BMI, but SGA and function of daily activities were similar to those of the non-vegetarians. The haematocrit of vegetarians can be maintained with a higher erythropoietin dose. © 2011 The Authors. Nephrology © 2011 Asian Pacific Society of Nephrology.

  6. Improvement of mineral and bone metabolism markers is associated with better survival in haemodialysis patients: the COSMOS study.

    PubMed

    Fernández-Martín, José Luis; Martínez-Camblor, Pablo; Dionisi, María Paula; Floege, Jürgen; Ketteler, Markus; London, Gérard; Locatelli, Francesco; Gorriz, José Luis; Rutkowski, Boleslaw; Ferreira, Aníbal; Bos, Willem-Jan; Covic, Adrian; Rodríguez-García, Minerva; Sánchez, José Emilio; Rodríguez-Puyol, Diego; Cannata-Andia, Jorge B

    2015-09-01

    Abnormalities in serum phosphorus, calcium and parathyroid hormone (PTH) have been associated with poor survival in haemodialysis patients. This COSMOS (Current management Of Secondary hyperparathyroidism: a Multicentre Observational Study) analysis assesses the association of high and low serum phosphorus, calcium and PTH with a relative risk of mortality. Furthermore, the impact of changes in these parameters on the relative risk of mortality throughout the 3-year follow-up has been investigated. COSMOS is a 3-year, multicentre, open-cohort, prospective study carried out in 6797 adult chronic haemodialysis patients randomly selected from 20 European countries. Using Cox proportional hazard regression models and penalized splines analysis, it was found that both high and low serum phosphorus, calcium and PTH were associated with a higher risk of mortality. The serum values associated with the minimum relative risk of mortality were 4.4 mg/dL for serum phosphorus, 8.8 mg/dL for serum calcium and 398 pg/mL for serum PTH. The lowest mortality risk ranges obtained using as base the previous values were 3.6-5.2 mg/dL for serum phosphorus, 7.9-9.5 mg/dL for serum calcium and 168-674 pg/mL for serum PTH. Decreases in serum phosphorus and calcium and increases in serum PTH in patients with baseline values of >5.2 mg/dL (phosphorus), >9.5 mg/dL (calcium) and <168 pg/mL (PTH), respectively, were associated with improved survival. COSMOS provides evidence of the association of serum phosphorus, calcium and PTH and mortality, and suggests survival benefits of controlling chronic kidney disease-mineral and bone disorder biochemical parameters in CKD5D patients. © The Author 2015. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  7. Interdialysis blood pressure control by long haemodialysis sessions.

    PubMed

    Chazot, C; Charra, B; Laurent, G; Didier, C; Vo Van, C; Terrat, J C; Calemard, E; Vanel, T; Ruffet, M

    1995-01-01

    High blood pressure (BP) is a major factor contributing to the high incidence of cardiovascular morbidity and mortality in haemodialysis (HD) patients. According to predialysis casual BP measurements, long HD has been shown to provide good BP control. To confirm this result during the period between dialysis sessions, we performed ambulatory monitoring of BP in 91 non-selected HD patients (mean age, 58.7 (14.1) years; 14% incidence of nephrosclerosis and diabetes mellitus; treatment duration, 93.0 (77.2) months; 3 x 8 h/week, cuprophane, acetate buffer in 95% of the patients). Only one patient (1.1%) was receiving an antihypertensive medication. Ambulatory BP results were systolic (S) BP, 119.4 (19.9) mmHg; diastolic (D) BP, 70.6 (12.9) mmHg; mean (M) BP, 87.6 (13.9) mmHg. These values were significantly lower than the casual predialysis BP data and close to the reference values reported by Staessen et al. in a meta-analysis including 3476 normotensive subjects. The MBP was inversely correlated with the treatment duration, but not with interdialysis weight gain. The MBP increased significantly in the last part of the interdialysis period, and this rise was not correlated with the interdialysis weight gain. The nocturnal/diurnal ratios for SBP and DBP for the HD patients (0.97 and 0.92) were higher than the reference values reported by Staessen, (0.87 and 0.83), and argued against a nocturnal decrease in BP. We found that 52.1% of the patients had an abnormal nocturnal BP fall (MBP fall < 5%). This feature worsened during the second night of the interdialysis period.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Ambulatory aortic blood pressure, wave reflections and pulse wave velocity are elevated during the third in comparison to the second interdialytic day of the long interval in chronic haemodialysis patients

    PubMed Central

    Koutroumbas, Georgios; Georgianos, Panagiotis I.; Sarafidis, Pantelis A.; Protogerou, Athanase; Karpetas, Antonios; Vakianis, Pantelis; Raptis, Vassilios; Liakopoulos, Vassilios; Panagoutsos, Stylianos; Syrganis, Christos; Passadakis, Ploumis

    2015-01-01

    Background Increased arterial stiffness and aortic blood pressure (BP) are independent predictors of cardiovascular outcomes in end-stage renal disease. The 3-day interdialytic interval is associated with elevated risk of cardiovascular morbidity and mortality in haemodialysis. This study investigated differences in ambulatory aortic BP and arterial stiffness between the second and third day of the long interdialytic interval. Methods Ambulatory BP monitoring with Mobil-O-Graph monitor (IEM, Stolberg, Germany) was performed in 55 haemodialysis patients during a 3-day interval. Mobil-O-Graph records oscillometric brachial BP and pulse waves and calculates aortic BP and augmentation index (AIx) as measure of wave reflections, and pulse wave velocity (PWV) as measure of arterial stiffness. Results Ambulatory aortic systolic blood pressure (SBP) and diastolic blood pressure (DBP) were higher during the third versus second interdialytic day (123.6 ± 17.0 versus 118.5 ± 17.1 mmHg, P < 0.001; 81.5 ± 11.8 versus 78 ± 11.9 mmHg, P < 0.001, respectively). Similar differences were noted for brachial BP. Ambulatory AIx and PWV were also significantly increased during the third versus second day (30.5 ± 9.9 versus 28.8 ± 9.9%, P < 0.05; 9.6 ± 2.3 versus 9.4 ± 2.3 m/s, P < 0.001, respectively). Differences between Days 2 and 3 remained significant when day-time and night-time periods were compared separately. Aortic SBP and DBP, AIx and PWV showed gradual increases from the end of dialysis session onwards. Interdialytic weight gain was a strong determinant of the increase in the above parameters. Conclusions This study showed significantly higher ambulatory aortic BP, AIx and PWV levels during the third compared with the second interdialytic day. These findings support a novel pathway for increased cardiovascular risk during the third interdialytic day in haemodialysis. PMID:25920919

  9. The impact of nurse-led education on haemodialysis patients' phosphate binder medication adherence.

    PubMed

    Sandlin, Kimberly; Bennett, Paul N; Ockerby, Cherene; Corradini, Ann-Marie

    2013-03-01

    Phosphate binder medication adherence is required to maintain optimal phosphate levels and minimise bone disease in people with end stage kidney disease. To examine the impact of a nurse-led education intervention on bone disorder markers, adherence to phosphate binder medication and medication knowledge. Descriptive study with a paired pre-post intervention survey. Adults receiving haemodialysis. Twelve-week intervention where patients self-administered their phosphate binder medication at each dialysis treatment. Nurses provided individualised education. Patients completed a pre- and post-intervention survey designed to explore their knowledge of phosphate binders. There were no statistically significant changes in clinical markers but a significant improvement in the proportion of patients who took their phosphate binder correctly, increasing from 44 to 72% (p = 0.016). There were moderate to large effect size changes for improved knowledge. A nurse-led intervention education programme can increase patients' phosphate binder adherence. However, this does not necessarily manifest into improved serum phosphate levels. © 2013 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  10. Performance of physical examination versus ultrasonography to detect stenosis in haemodialysis arteriovenous fistula.

    PubMed

    Maldonado-Cárceles, Ana B; García-Medina, José; Torres-Cantero, Alberto M

    2017-01-18

    The overall purpose of this study is to compare the accuracy of physical examination (PE) versus ultrasonography (US) in people with arteriovenous fistula (AVF). This is a cross-sectional study with a total of 99 patients attended by the vascular radiology unit for AVF evaluation during January - March 2015. PE and ultrasonography were blinded performed by different radiologists. For complete and individual signs of PE, sensitivity, specificity, predictive positive (PPV) and negative (PNV) value, likelihood ratios (LR) and Cohen's κ value were measured. According to ultrasonography, the presence of stenosis was identified in 57 (58%) patients, and 61 (62%) by PE. The accuracy of PE for the diagnosis of AVF was sensitivity 82%, specificity 67%, PPV 77%, NPV 74%, LR 2.74 and 0.26. There was a moderate agreement beyond chance between PE and ultrasonography (κ = 0.5). PE has shown a moderate accuracy to detect stenosis. With non-ultrasonography availability Haemodialysis Units can get benefit to optimize VA survival and professionals should improve its basic skills.

  11. Quality of life of Greek patients with end stage renal disease undergoing haemodialysis.

    PubMed

    Kastrouni, Maria; Sarantopoulou, Eleni; Aperis, Georgios; Alivanis, Polichronis

    2010-09-01

    An evaluation of the quality of life of patients with end stage kidney disease undergoing haemodialysis in the Greek population was conducted to understand whether this quality could be improved. Comparisons were made with a similar study conducted in United States in regards to the effects of kidney disease in daily life, burden of kidney disease, work status, cognitive function, quality of social interaction, sexual function, social support, physical functioning, role physical on daily routine, pain, general health perceptions, role emotional, emotional well being, social function and energy/fatigue. Any differences are discussed and analysed. Sexual problems were found to be more prominent in this study, but the emotional status has greater influence in quality of life in the US study. The results were more positive in Greece with respect to dialysis staff encouragement, patient satisfaction, as well as acceptance and the understanding of illness. The results from our study reflect the differences of the health care systems in various countries as well as population-related beliefs and values.

  12. The management of xerostomia in patients on haemodialysis: comparison of artificial saliva and chewing gum.

    PubMed

    Bots, Casper P; Brand, Henk S; Veerman, Enno C I; Valentijn-Benz, Marianne; Van Amerongen, Barbara M; Nieuw Amerongen, Arie V; Valentijn, Robert M; Vos, Pieter F; Bijlsma, Joost A; Bezemer, Pieter D; ter Wee, Piet M

    2005-04-01

    Many patients on haemodialysis (HD) therapy suffer from a dry mouth and xerostomia. This can be relieved by mechanical and gustatory stimulation or palliative care. The aim of this crossover study was to investigate the effect and preferences of a sugar-free chewing gum (Freedent White) and a xanthan gum-based artificial saliva (Xialine) in the management of xerostomia in chronic HD patients. Sixty-five HD patients participated in a 6-week crossover trial. The artificial saliva was rated significantly lower than the chewing gum for effectiveness, taste and a global assessment. No preference differences were found for gender and age, although older subjects rated the artificial saliva with a higher mark. Thirty-nine subjects (60%) preferred chewing gum, 15% (n=10) preferred the artificial saliva. Therefore, both chewing gum and artificial saliva could play an important role in the palliative care of xerostomia in HD patients.

  13. A composite score of protein-energy nutritional status predicts mortality in haemodialysis patients no better than its individual components.

    PubMed

    Mazairac, Albert H A; de Wit, G Ardine; Grooteman, Muriel P C; Penne, E Lars; van der Weerd, Neelke C; van den Dorpel, Marinus A; Nubé, Menso J; Lévesque, Renée; Ter Wee, Piet M; Bots, Michiel L; Blankestijn, Peter J

    2011-06-01

    Protein-energy wasting is tightly associated with mortality in haemodialysis patients. An expert panel of the International Society of Renal Nutrition and Metabolism (ISRNM) has published a consensus on the parameters that define protein-energy nutritional status and posed the question, 'which scoring system most effectively predicts outcome?' The aim of our study was therefore to develop a composite score of protein-energy nutritional status (cPENS) and to assess its prediction of all-cause mortality. We used the data of 560 haemodialysis patients participating in the CONvective TRAnsport STudy (CONTRAST). All participants were followed for occurrence of death. Internationally recommended nutritional targets were used as components of the cPENS, including the subjective global assessment (target score ≥ 6), albumin (≥ 4.0 g/dL), normalized protein nitrogen appearance (≥ 0.8 g/kg/day), cholesterol (≥ 100 mg/dL), creatinine (≥ 10 mg/dL) and BMI (> 23 kg/m(2)). A Cox regression model was used to analyse the relation between different cPENS variants and mortality. The median follow-up time was 1.4 years (max 4.2). One hundred and five patients (19%) died. A cPENS variant based on albumin, BMI, creatinine and the nPNA yielded the strongest relation with mortality (hazard ratio 0.63, 95% confidence interval 0.54-0.74, P < 0.001), after adjustments for confounders. Some of the individual parameters of the cPENS, notably albumin and creatinine, were related to mortality with similar strength and magnitude. In conclusion, albumin reflects mortality risk similarly to multiple nutritional parameters combined. This questions the clinical value of the proposed diagnostic criteria for protein-energy wasting.

  14. Outcomes of overseas kidney transplantation in chronic haemodialysis patients in Taiwan.

    PubMed

    Hsu, Chih-Cheng; Lee, Cheng-Hua; Hwang, Shang-Jyh; Huang, Shi-Wei; Yang, Wu-Chang; Chang, Yu-Kang; Tsai, Daniel Fu-Chang; Kuo, Ken N

    2011-03-01

    Overseas kidney transplantation has often been reported to have unsatisfactory outcomes. This study aims to compare post-transplantation outcomes between overseas and domestic kidney transplant (KT) recipients in Taiwan. The Taiwanese National Health Insurance Research Database was used to identify 310 domestic and 643 overseas KT recipients, who survived for longer than 1 month after the transplantation, in a cohort of 45,453 chronic haemodialysis patients in 1997-2002. Cox proportional hazards models were used to assess risks of mortality and graft failure. The 1, 3 and 5 year survival rates for domestic KT recipients were 96.5%, 93.3% and 91.6%, respectively, while those for overseas KT recipients were 94.9%, 87.9% and 77.1%, respectively (P = 0.015). For the overseas group, those who received a KT before 2001 had significantly higher hazard ratios of mortality and graft failure (2.85 and 1.71, respectively). However, for those receiving a KT in 2001-2002, no significant outcome difference could be found between overseas and domestic recipients. The risk disparity between overseas and domestic KT recipients is mainly attributable to when the transplantation was performed. In attempting to dissuade potential recipients from organ trafficking, merely emphasizing the previously acknowledged poor outcomes no longer suffices as a valid reason. © 2011 The Authors. Nephrology © 2011 Asian Pacific Society of Nephrology.

  15. A structured exercise programme during haemodialysis for patients with chronic kidney disease: clinical benefit and long-term adherence

    PubMed Central

    Anding, Kirsten; Bär, Thomas; Trojniak-Hennig, Joanna; Kuchinke, Simone; Krause, Rolfdieter; Rost, Jan M; Halle, Martin

    2015-01-01

    Objective Long-term studies regarding the effect of a structured physical exercise programme (SPEP) during haemodialysis (HD) assessing compliance and clinical benefit are scarce. Study design A single-centre clinical trial, non-randomised, investigating 46 patients with HD (63.2±16.3 years, male/female 24/22, dialysis vintage 4.4 years) performing an SPEP over 5 years. The SPEP (twice/week for 60 min during haemodialysis) consisted of a combined resistance (8 muscle groups) and endurance (supine bicycle ergometry) training. Exercise intensity was continuously adjusted to improvements of performance testing. Changes in endurance and resistance capacity, physical functioning and quality of life (QoL) were analysed over 1 year in addition to long-term adherence and economics of the programme over 5 years. Average power per training session, maximal strength tests (maximal exercise repetitions/min), three performance-based tests for physical function, SF36 for QoL were assessed in the beginning and every 6 months thereafter. Results 78% of the patients completed the programme after 1 year and 43% after 5 years. Participants were divided—according to adherence to the programme—into three groups: (1) high adherence group (HA, >80% of 104 training sessions within 12 months), (2) moderate adherence (MA, 60–80%), and 3. Low adherence group (LA, <60%)) with HA and MA evaluated quantitatively. One-year follow-up data revealed significant (p<0.05) improvement for both groups in all measured parameters: exercise capacity (HA: 55%, MA: 45%), strength (HA: >120%, MA: 40–50%), QoL in three scores of SF36 subscales and physical function in the three tests taken between 11% and 31%. Moreover, a quantitative correlation analysis revealed a close association (r=0.8) between large improvement of endurance capacity and weak physical condition (HA). Conclusions The exercise programme described improves physical function significantly and can be integrated

  16. A structured exercise programme during haemodialysis for patients with chronic kidney disease: clinical benefit and long-term adherence.

    PubMed

    Anding, Kirsten; Bär, Thomas; Trojniak-Hennig, Joanna; Kuchinke, Simone; Krause, Rolfdieter; Rost, Jan M; Halle, Martin

    2015-08-27

    Long-term studies regarding the effect of a structured physical exercise programme (SPEP) during haemodialysis (HD) assessing compliance and clinical benefit are scarce. A single-centre clinical trial, non-randomised, investigating 46 patients with HD (63.2 ± 16.3 years, male/female 24/22, dialysis vintage 4.4 years) performing an SPEP over 5 years. The SPEP (twice/week for 60 min during haemodialysis) consisted of a combined resistance (8 muscle groups) and endurance (supine bicycle ergometry) training. Exercise intensity was continuously adjusted to improvements of performance testing. Changes in endurance and resistance capacity, physical functioning and quality of life (QoL) were analysed over 1 year in addition to long-term adherence and economics of the programme over 5 years. Average power per training session, maximal strength tests (maximal exercise repetitions/min), three performance-based tests for physical function, SF36 for QoL were assessed in the beginning and every 6 months thereafter. 78% of the patients completed the programme after 1 year and 43% after 5 years. Participants were divided--according to adherence to the programme--into three groups: (1) high adherence group (HA, >80% of 104 training sessions within 12 months), (2) moderate adherence (MA, 60-80%), and 3. Low adherence group (LA, <60%)) with HA and MA evaluated quantitatively. One-year follow-up data revealed significant (p<0.05) improvement for both groups in all measured parameters: exercise capacity (HA: 55%, MA: 45%), strength (HA: >120%, MA: 40-50%), QoL in three scores of SF36 subscales and physical function in the three tests taken between 11% and 31%. Moreover, a quantitative correlation analysis revealed a close association (r=0.8) between large improvement of endurance capacity and weak physical condition (HA). The exercise programme described improves physical function significantly and can be integrated into a HD routine with a high long-term adherence. Published by the

  17. The effect of fluid overload on sleep apnoea severity in haemodialysis patients.

    PubMed

    Lyons, Owen D; Inami, Toru; Perger, Elisa; Yadollahi, Azadeh; Chan, Christopher T; Bradley, T Douglas

    2017-04-01

    As in heart failure, obstructive and central sleep apnoea (OSA and CSA, respectively) are common in end-stage renal disease. Fluid overload characterises end-stage renal disease and heart failure, and in heart failure plays a role in the pathogenesis of OSA and CSA. We postulated that in end-stage renal disease patients, those with sleep apnoea would have greater fluid volume overload than those without.End-stage renal disease patients on thrice-weekly haemodialysis underwent overnight polysomnography on a nondialysis day to determine their apnoea-hypopnoea index (AHI). Extracellular fluid volume of the total body, neck, thorax and right leg were measured using bioelectrical impedance.28 patients had an AHI ≥15 (sleep apnoea group; OSA:CSA 21:7) and 12 had an AHI <15 (no sleep apnoea group). Total body extracellular fluid volume was 2.6 L greater in the sleep apnoea group than in the no sleep apnoea group (p=0.006). Neck, thorax, and leg fluid volumes were also greater in the sleep apnoea than the no sleep apnoea group (p<0.05), despite no difference in body mass index (p=0.165).These findings support a role for fluid overload in the pathogenesis of both OSA and CSA in end-stage renal disease. Copyright ©ERS 2017.

  18. True Brachial Artery Aneurysm in a Patient with Vascular Access for Haemodialysis and Kidney Graft.

    PubMed

    Correia, Mafalda; Marinho, André; Mendes, Carolina; Antunes, Luís; Gonçalves, Óscar

    2017-01-01

    True brachial artery aneurysms are rare and some of them have been described as a late complication in patients with vascular access for haemodialysis and kidney graft. The purpose of this paper is to present a clinical case of a patient with a true brachial artery aneurysm and its following treatment. This case concerns a caucasian male patient with 43 years old who had vesicoureteral reflux at 7 years old, and subsequent end-stage renal disease, and started on haemodialysis at the age of twelve. The patient had homolateral radial and brachiocephalic arteriovenous fistulas (AVF), two sequential kidney grafts and was under immunosuppressant therapy for several years. As part of the medical history he also had bilateral amaurosis, Hepatitis B and C and was submitted to total parathyroidectomy and a following auto-transplant. In the latest years the patient presented with several aneurysms related to the vascular access. After the finding of an anastomotic false aneurysm and venous aneurysms complicating the AVF, the patient had removal of the aneurysms and ligation of the AVF. Later, he was diagnosed, in different times, with two true brachial artery aneurysms. At the time of the diagnosis of the first true aneurysm, the patient presented with local pain and occasional paraesthesias relative to compression symptoms. At physical examination the patient had a brachial pulsatile mass and a palpable radial pulse. The Doppler ultrasound exam revealed a true brachial artery aneurysm with 4,5 cm diameter. After two years, the patient was once again diagnosed with a true brachial artery aneurysm with 3,1 cm diameter. At this time the patient was asymptomatic and had palpable brachial mass and radial pulse. At the time of the diagnosis of the first true brachial aneurysm the patient was submitted to partial aneurysmectomy and brachiobrachial graft with PTFE 8. The patency of the graft persisted until the diagnosis of the second aneurysm. After two years, the patient was

  19. Immunogenicity and safety of the 13-valent Pneumococcal Conjugate vaccine in 23-valent pneumococcal polysaccharide vaccine-naive and pre-immunized patients under treatment with chronic haemodialysis: a longitudinal quasi-experimental phase IV study.

    PubMed

    Vandecasteele, S J; De Bacquer, D; Caluwe, R; Ombelet, S; Van Vlem, B

    2018-01-01

    To benchmark the immunogenicity of pneumococcal conjugated vaccine (PCV-13) versus pneumococcal polysaccharide vaccine (PPV-23) in haemodialysis patients pre-vaccinated or not with PPV-23. The study is a longitudinal quasi-experimental phase IV study in chronic haemodialysis patients aged ≥50 years. Total (ELISA) and functional (opsonophagocytic assay) antibodies after pneumococcal vaccination were quantified at baseline, and after 28 and 365 days. Of 201 eligible patients, 155 were included. Patients were divided in four groups. PPV-23 naive patients were randomized to PPV-23 (40) or PCV-13 (40) vaccination. PPV-23-pre-vaccinated patients were categorized as being vaccinated more (40) or less (35) than 4 years before the study and all received PCV-13. Patients among the four groups had a significant ELISA antibody response for most serotypes that remained significant up to day 365 versus baseline. In PPV-23-naive patients, ELISA antibody titres were significantly higher among PCV-13 versus PPV-23 recipients for six serotypes (1.85-2.34-fold) after 28 days, and remained significantly higher for one serotype (6A, 1.57-fold) after 365 days. Following PCV-13 vaccination, increase in ELISA antibody titres was significantly higher among PPV-23-naive versus PPV-23-pre-vaccinated patients for 12 serotypes after 28 days (1.68-7.74-fold) and remained significantly higher in ten serotypes (1.44-3.29-fold) after 365 days. Immune response after PPV-23 and PCV-13 remains significant for at least 1 year in non-PPV-23-pre-vaccinated patients. Among vaccine-naive haemodialysis patients PCV-13 seems more immunogenic than PPV-23. Immune response to PCV-13 is weaker in PPV-23-pre-vaccinated compared with vaccine-naive patients. Copyright © 2017. Published by Elsevier Ltd.

  20. Ambulatory aortic blood pressure, wave reflections and pulse wave velocity are elevated during the third in comparison to the second interdialytic day of the long interval in chronic haemodialysis patients.

    PubMed

    Koutroumbas, Georgios; Georgianos, Panagiotis I; Sarafidis, Pantelis A; Protogerou, Athanase; Karpetas, Antonios; Vakianis, Pantelis; Raptis, Vassilios; Liakopoulos, Vassilios; Panagoutsos, Stylianos; Syrganis, Christos; Passadakis, Ploumis

    2015-12-01

    Increased arterial stiffness and aortic blood pressure (BP) are independent predictors of cardiovascular outcomes in end-stage renal disease. The 3-day interdialytic interval is associated with elevated risk of cardiovascular morbidity and mortality in haemodialysis. This study investigated differences in ambulatory aortic BP and arterial stiffness between the second and third day of the long interdialytic interval. Ambulatory BP monitoring with Mobil-O-Graph monitor (IEM, Stolberg, Germany) was performed in 55 haemodialysis patients during a 3-day interval. Mobil-O-Graph records oscillometric brachial BP and pulse waves and calculates aortic BP and augmentation index (AIx) as measure of wave reflections, and pulse wave velocity (PWV) as measure of arterial stiffness. Ambulatory aortic systolic blood pressure (SBP) and diastolic blood pressure (DBP) were higher during the third versus second interdialytic day (123.6 ± 17.0 versus 118.5 ± 17.1 mmHg, P < 0.001; 81.5 ± 11.8 versus 78 ± 11.9 mmHg, P < 0.001, respectively). Similar differences were noted for brachial BP. Ambulatory AIx and PWV were also significantly increased during the third versus second day (30.5 ± 9.9 versus 28.8 ± 9.9%, P < 0.05; 9.6 ± 2.3 versus 9.4 ± 2.3 m/s, P < 0.001, respectively). Differences between Days 2 and 3 remained significant when day-time and night-time periods were compared separately. Aortic SBP and DBP, AIx and PWV showed gradual increases from the end of dialysis session onwards. Interdialytic weight gain was a strong determinant of the increase in the above parameters. This study showed significantly higher ambulatory aortic BP, AIx and PWV levels during the third compared with the second interdialytic day. These findings support a novel pathway for increased cardiovascular risk during the third interdialytic day in haemodialysis. © The Author 2015. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  1. Usefulness of questionnaires on advance directives in haemodialysis units.

    PubMed

    Jornet, Angel Rodríguez; Castellanos, Loreley Ana Betancourt; Contador, Maria Isabel Bolós; Morera, Juan Carlos Oliva; López, José Antonio Ibeas

    2017-10-01

    As renal replacement therapy has become universal practice in medicine, there is a need to consider whether this treatment is suitable for elderly people. These patients have high comorbidity and may require dialysis withdrawal in certain clinical circumstances. Advance directives (ADs) drawn up by patients facilitate treatment-related decisions if they lose cognitive capacity. Questionnaires dealing with possible extreme clinical circumstances can thus help clinicians and relatives reach pertinent decisions in such cases. We studied the usefulness of questionnaires on ADs in patients who started periodic haemodialysis over a period of 10 years. Telephone interviews were conducted to assess satisfaction level among relatives/representatives of deceased patients who had been advised to limit therapeutic efforts in certain clinical situations. The questionnaire was assessed using a six-factor degree of satisfaction. Four hundred and forty-three questionnaires were distributed over a period of 10 years. A total of 41.3% of patients stated that they wished to limit therapeutic efforts in the serious clinical situations presented; 37.9% refused to complete the questionnaire; 14.7% expressed their wishes without any written confirmation; and 6.1% expressed their wish to continue on dialysis in all situations. Two hundred and twenty-four patients had died by the study end date. The cause of death in 20.2% was scheduled dialysis withdrawal. Representatives reported an extremely high degree of satisfaction with the questionnaire (94.7%). Younger people, however, were more reluctant to consider and answer questionnaires on ADs. Questionnaires on ADs are a useful tool in daily nephrology practice and should be distributed to those patients willing to consider the limitation of therapeutic efforts in extreme clinical circumstances. In general terms, these questionnaires should be given to all elderly patients. © The Author 2017. Published by Oxford University Press on

  2. Cephalic Arch Stenosis in Autogenous Haemodialysis Fistulas: Treatment With the Viabahn Stent-Graft

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shawyer, Andrew, E-mail: andrew.shawyer@bartsandthelondon.nhs.uk; Fotiadis, Nicos I., E-mail: fotiadis.nicholas@gmail.com; Namagondlu, Girish, E-mail: girish.namagondlu@bartsandthelondon.nhs.uk

    2013-02-15

    Cephalic arch stenosis (CAS) is an important and common cause of dysfunction in autogenous haemodialysis fistulas that requires multiple reinterventions and aggressive surveillance. We evaluated the safety and efficacy of the Viabahn stent-graft for the management of CAS. Between April 2005 and October 2011, 11 consecutive patients [four men and seven women (mean age 56.7 years)] with CAS and dysfunctional fistulas were treated with insertion of 11 Viabahn stent-grafts. Six stent-grafts were inserted due to residual stenosis after angioplasty and five for fistuloplasty-induced rupture. No patient was lost to follow-up. The technical and clinical success rate was 100 %. Primarymore » access patency rates were 81.8 % [95 % confidence interval (CI) 0.482-0.977] at 6 months and 72.7 % (95 % CI 0.390-0.939) at 12 months. Secondary access patency rates were 90.9 % at 6 months (95 % CI 0.587-0.997). There were no procedure-related complications. Mean follow-up was 543.8 days (range 156-2,282). The use of the Viabahn stent-graft in the management of CAS is technically feasible and, in this small series, showed patency rates that compare favorably with historical data of angioplasty and bare stents.« less

  3. Clinical and patient‐reported outcomes of Chinese patients undergoing haemodialysis in hospital or in the community: A 1‐year longitudinal study

    PubMed Central

    Wan, Eric YF; Choi, Edmond PH; Wong, Carlos KH; Chan, Anca KC; Chan, Karina HY; Li, Philip KT; Lam, Cindy LK

    2016-01-01

    Abstract Aim Little is known about the effect of haemodialysis (HD) setting on outcomes of patients with end stage renal disease (ESRD). The study aimed at comparing clinical outcomes and patient‐reported outcomes (PRO) of patients on community‐based (CBHD) and hospital‐based haemodialysis (HBHD). Methods A prospective cohort of Chinese ESRD patients receiving HBHD (n = 89) or CBHD (n = 117) in Hong Kong were followed up for 12 months. Subjects were assessed on clinical outcomes of dialysis adequacy (Kt/V) and blood haemoglobin and PRO of health‐related quality of life (SF‐12v2), general health condition (Global Rating Scale (GRS)) and confidence to cope with their illness (Patient Enablement Instrument (PEI)). Differences between groups were analyzed by independent t‐tests for the SF‐12v2, GRS and PEI scores. χ2 tests were used to analyze the difference in proportion of patients reaching the targets of Kt/V and blood haemoglobin and with GRS > 0 and PEI > 0. Multiple linear and logistic regressions were performed to assess the adjusted difference‐in‐difference estimation. Results The mean PEI and GRS scores of CBHD patients at 12 months were significantly higher than those of HBHD patients. CBHD patients had significantly greater improvement in self‐efficacy and were more likely to be enabled after 12 months than the HBHD patients. Conclusion The study showed similar clinical outcomes and PRO between CBHD and HBHD but CBHD was more effective than HBHD in promoting patient enablement over a 12‐month period. The results suggest added value for patients receiving CBHD and support the transfer of HD care from the hospital to the community. PMID:26616825

  4. Improving distress in dialysis (iDiD): a feasibility two-arm parallel randomised controlled trial of an online cognitive behavioural therapy intervention with and without therapist-led telephone support for psychological distress in patients undergoing haemodialysis

    PubMed Central

    Hudson, Joanna L; Moss-Morris, Rona; Game, David; Carroll, Amy; McCrone, Paul; Hotopf, Matthew; Yardley, Lucy; Chilcot, Joseph

    2016-01-01

    Introduction Psychological distress is common in end-stage kidney disease (ESKD) and is associated with poorer health outcomes. Cognitive behavioural therapy (CBT) is recommended in UK clinical guidelines for the management of depression in people with long-term conditions. Access to skilled therapists competent in managing the competing mental and physical health demands of ESKD is limited. Online CBT treatments tailored to the needs of the ESKD population offers a pragmatic solution for under-resourced services. This study examines the feasibility and acceptability of implementing a two-arm parallel randomised controlled trial of online CBT with (intervention arm) and without (control arm) therapist support to improve psychological distress in patients undergoing haemodialysis. Methods Patients will be screened for depression and anxiety while attending for their haemodialysis treatments. We aim to recruit 60 adult patients undergoing haemodialysis who meet criteria for mild to moderately severe symptoms of depression and/or anxiety. Patients will be randomised individually (using a 1:1 computerised sequence ratio) to either online CBT with therapist telephone support (intervention arm), or online CBT with no therapist (control arm). Outcomes include feasibility and acceptability descriptive data on rates of recruitment, randomisation, retention and treatment adherence. Self-report outcomes include measures of depression (Patient Health Questionnaire-9), anxiety (Generalised Anxiety Disorder-7), quality of life (Euro-QoL), service use (client service receipt inventory) and illness cognitions (brief illness perception questionnaire). A qualitative process evaluation will also be conducted. The statistician will be blinded to treatment allocation. Ethics and dissemination A National Health Service (NHS) research ethics committee approved the study. Data from this study will provide essential information for the design and testing of further interventions to

  5. Evaluation of the quality of care of a haemodialysis public-private partnership programme for patients with end-stage renal disease.

    PubMed

    Chen, Julie Y; Wan, Eric Y F; Chan, Karina H Y; Chan, Anca K C; Chan, Frank W K; Lam, Cindy L K

    2016-07-11

    Haemodialysis (HD) is one of the life-saving options for patients with end stage renal disease but demand for this treatment exceeds capacity in publicly funded hospitals. One novel approach to addressing this problem is through a shared-care model whereby government hospitals partner with qualified private HD service providers to increase the accessibility of HD for needy patients. The aim of this study is to evaluate and enhance the quality of care (QOC) provided in such a shared-care programme in Hong Kong, the Haemodialysis Public-Private Partnership Programme (HD-PPP). This is a longitudinal study based on Action Learning and Audit Spiral methodologies to measure the achievement of pre-set target standards for the HD-PPP programme over three evaluation cycles. The QOC evaluation framework is comprised of structure, process and outcome criteria with target standards in each domain developed from review of the evidence and in close collaboration with the HD-PPP working group. During each evaluation cycle, coordinators of each study site complete a questionnaire to determine adherence with structural criteria of care. Process and clinical outcomes, such as adverse events and dialysis adequacy, are extracted from the patient records of consenting study participants while face-to-face interviews are conducted to ascertain patient-reported outcomes such as self-efficacy and health-related quality of life. The study relies on the successful implementation of partnership-based action research to develop an evidence-based and pragmatic framework for evaluation of quality of care in an iterative fashion, and to use it to identify possible areas of quality enhancements in a shared-care programme for HD patients. The approach we take in this study emphasizes partnership and engagement with the clinical and administrative programme team, a robust but flexible evaluation framework, direct observation and the potential to realize positive change. The experience will be

  6. Costs and added value of haemodialysis and peritoneal dialysis outsourcing agreements.

    PubMed

    Lamas Barreiro, J M; Alonso Suárez, M; Saavedra Alonso, J A; Gándara Martínez, A

    2011-01-01

    Despite the discrepancy in results from Spanish studies on the costs of dialysis, it is assumed that peritoneal dialysis (PD) is more efficient than haemodialysis (HD). To analyse the costs and added value of HD and PD outsourcing agreements in Galicia, the medical transport for HD and the relationship between the cost of the agreement and the cost of consumables used in continuous ambulatory peritoneal dialysis (CAPD) with bicarbonate. The cost of the outsourcing agreements and the staff was obtained from official publications. The cost of PD and medical transport were calculated using health service data for one month and extrapolating it to one year. The cost of CAPD consumables was provided by the suppliers. The added value was calculated from the investments generated for each agreement treating 40 patients. Expressed as patient/year, the mean costs for treatment were €21595 and €25664 in HD and PD, respectively. Medical transport varied between €3323 and €6338, while those of the CAPD agreement and consumables were €19268 and €12057, respectively. The added value was greater with the HD agreement, especially considering the jobs created. One cannot generalise that the cost of PD, which is significantly influenced by prescriptions, is lower than that of HD. It would be appropriate to review the additional cost to consumables in the CAPD agreement. The added value generated by dialysis agreements should be considered in future studies and in health planning. More controlled studies are needed to better understand this issue.

  7. The influence of uraemia and haemodialysis on neutrophil phagocytosis and antimicrobial killing.

    PubMed

    Anding, Kirsten; Gross, Peter; Rost, Jan M; Allgaier, Dirk; Jacobs, Enno

    2003-10-01

    Neutrophil functions in haemodialysis (HD) patients are altered by uraemia and by HD procedure. We investigated details of the neutrophil dysfunction as its nature and origin is not well understood. This is reflected by conflicting results about neutrophil phagocytosis activity and by scarce data on the neutrophil killing capability in HD patients. Using a flow-cytometric test system we have measured simultaneously phagocytosis and the production of reactive oxygen species (ROS) of neutrophils and in parallel antimicrobial killing of yeast by neutrophils. 117 whole-blood samples of healthy controls and 50 pre- and 50 post-dialysis samples of HD patients, half of them with diabetes mellitus (DM), have been evaluated. We have constructed a model to account for the dependence on the stimulus-to-cell ratio and obtain means for phagocytosis and killing at different incubation times. (i) HD patients have significantly lower neutrophil killing (20%) than healthy controls. (ii) Dialysis improves the killing capability by 10-15%, after dialysis the killing activity remains significantly (10%) below that of the controls. (iii) The percentage of neutrophils, which exhibit phagocytosis and produce ROS, does not differ significantly between HD patients and healthy controls. (iv) Age has no significant influence on phagocytosis and killing. The neutrophil killing capability is reduced in HD patients while the amount of neutrophils that phagocyte and produce ROS remains unchanged. Functional impairment of uraemic neutrophils is therefore mainly a result of their reduced capability to kill microorganisms intracellularly.

  8. Prevalence of chronic itch and associated factors in haemodialysis patients: a representative cross-sectional study.

    PubMed

    Weiss, Melanie; Mettang, Thomas; Tschulena, Ulrich; Passlick-Deetjen, Jutta; Weisshaar, Elke

    2015-09-01

    Chronic itch is a common symptom in haemodialysis (HD) patients, which is often underestimated. The aim of this cross-sectional study was to investigate the prevalence and factors associated with chronic itch in HD patients. A total of 860 HD patients from a randomly selected cluster-sample of patients attending dialysis units in Germany were included. The patients' mean?±?SD age was 67.2?±?13.5 years, 57.2% were male. The point prevalence of chronic itch was 25.2% (95% CI 22.4-28.1), 12-month prevalence was 27.2% (95% CI 24.1-30.3) and lifetime prevalence was 35.2% (95% CI 31.9-38.3). Chronic itch was significantly less prevalent in patients with secondary glomerulonephritis as primary renal disease. A history of dry skin, eczema, and age

  9. Effect of FX dialysers on systemic inflammation and quality of life in chronic haemodialysis patients.

    PubMed

    Boudville, Neil; Horner, Marilyn; McEwan, Elizabeth; Lim, Wai H; Mudge, David W; Markus, Hadley E

    2009-01-01

    The FX class of haemodialysers features a new class of high-flux polysulfone membrane which has been suggested to induce less inflammation. This was a randomized, cross-over study performed on 33 haemodialysis patients. Patients were randomized to FX60 or HF80 dialysers for 3 months and then changed to the other dialyser. Interleukin-6 (IL-6), tumour necrosis factor-alpha (TNF-alpha), and C-reactive protein (CRP) were measured at baseline, and every 3 months. The Kidney Disease Quality of Life Short Form was also administered. The mean of the difference in the IL-6 level between dialysers was 1.4 +/- 8.0 pg/ml (95% CI -1.8, 4.5 pg/ml). There was no significant difference in TNF-alpha (95% CI -0.35, 0.18 pg/ml) or CRP levels (95% CI -2.67, 6.20 mg/l). The quality of social interaction and role limitations caused by physical health problems were significantly higher with the FX60, p = 0.04 and 0.047, respectively. The FX dialysers do not result in a significant difference in the level of systemic inflammation compared to the HF80.

  10. Medication beliefs are associated with phosphate binder non-adherence in hyperphosphatemic haemodialysis patients.

    PubMed

    Wileman, Vari; Farrington, Ken; Wellsted, David; Almond, Mike; Davenport, Andrew; Chilcot, Joseph

    2015-09-01

    Patients with end-stage kidney disease receiving haemodialysis (HD) are at risk of cardiovascular disease and bone disorders related to high levels of serum phosphate. We studied the association between medication beliefs and depressive symptoms, with non-adherence to phosphate binding medication in a group of HD patients at risk of complications due to hyperphosphatemia. Cross-sectional design. Baseline data from 112 patients participating in a randomized controlled trial, evaluating an adherence intervention, are presented. All patients had serum phosphate levels >1.6 mmol/l at baseline. Adherence was measured by (1) serum phosphate and (2) Medication Adherence Report Scales (MARS). Beliefs about Medicines (BMQ) and depressive symptoms (PHQ-9) were also evaluated. Beliefs about Medicines Questionnaire necessity, but not concerns, beliefs were found to correlate with serum phosphate (r = -.23, p < .05) and self-reported adherence (r = .35, p < .01). In regression models, controlling for demographic, clinical and psychological variables, necessity beliefs explained the variance of serum phosphate (β = -.22, p = .01) and self-reported adherence (β = .30, p ≤ .01). Both BMQ concerns and depressive symptoms were not related to non-adherence. Patients' beliefs about the necessity of their prescribed phosphate binding medications explain variation in non-adherence levels, measured both subjective and objectively. Dialysis patient's medication beliefs are potentially modifiable targets for future interventions. © 2014 The British Psychological Society.

  11. Nutritional parameters as mortality predictors in haemodialysis: Differences between genders.

    PubMed

    Oliveira, Telma Sobral; Valente, Ana Tentúgal; Caetano, Cristina Guerreiro; Garagarza, Cristina Antunes

    2017-06-01

    Malnutrition is common in patients undergoing haemodialysis (HD). Several studies have described different nutritional parameters as mortality predictors but few have studied whether there are differences between genders. This study aimed to evaluate which nutrition parameters may be associated with mortality in patients undergoing long-term HD depending on their gender. Longitudinal prospective multicentre study with 12 months of follow-up. Anthropometric and laboratory measures were obtained from 697 patients. Men who died were older, had lower dry weight, body mass index, potassium, phosphorus and albumin, compared with male patients who survived. Female patients who died had lower albumin and nPCR compared with survivors. Kaplan-Meier analysis displayed a significantly worse survival in patients with albumin <3.5 g/dl in both genders and with body mass index <23 kg/m 2 in men. In the Cox regression analysis patients overall mortality was related to body mass index <23 kg/m 2 , potassium ≤5.5 mEq/l and phosphorus <3.0 mg/dl for male patients and albumin <3.5 g/dl and normalised protein catabolic rate (nPCR) <0.8 g/kg/day for both genders. Associations between albumin, body mass index and mortality risk continued to be significant after adjustments for age, length of time on dialysis and diabetes for males. However, in women, only albumin persisted as an independent predictor of death. Depending on the gender, different parameters such as protein intake, potassium, phosphorus, body mass index and albumin are associated with mortality in patients undergoing HD. Albumin <3.5 g/dl is an independent mortality predictor in both genders, whereas a body mass index <23 kg/m 2 is an independent predictor of death, but only in men. © 2017 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  12. Streptococcus uberis and Staphylococcus aureus forefoot and blood stream co-infection in a haemodialysis patient: a case report.

    PubMed

    Valentiny, Christine; Dirschmid, Harald; Lhotta, Karl

    2015-05-28

    Streptococcus uberis, the most frequent cause of mastitis in lactating cows, is considered non-pathogenic for humans. Only a few case reports have described human infections with this microorganism, which is notoriously difficult to identify. We report the case of a 75-year-old male haemodialysis patient, who developed a severe foot infection with osteomyelitis and bacteraemia. Both Streptococcus uberis and Staphylococcus aureus were identified in wound secretion and blood samples using mass spectrometry. The presence of Streptococcus uberis was confirmed by superoxide dismutase A sequencing. The patient recovered after amputation of the forefoot and antibiotic treatment with ampicillin/sulbactam. He had probably acquired the infection while walking barefoot on cattle pasture land. This is the first case report of a human infection with Streptococcus uberis with identification of the microorganism using modern molecular technology. We propose that Staphylococcus aureus co-infection was a prerequisite for deep wound and bloodstream infection with Streptococcus uberis.

  13. Phosphate, urea and creatinine clearances: haemodialysis adequacy assessed by weekly monitoring.

    PubMed

    Debowska, Malgorzata; Wojcik-Zaluska, Alicja; Ksiazek, Andrzej; Zaluska, Wojciech; Waniewski, Jacek

    2015-01-01

    The specific distribution of phosphate and the control mechanisms for its plasma level makes phosphate kinetics during haemodialysis (HD) considerably different from those of urea and creatinine and makes the quantitative evaluation of adequacy of phosphate removal difficult. We propose the application of equivalent continuous clearance (ECC) as a phosphate adequacy parameter and compare it with ECC for creatinine and urea. Three consecutive dialysis sessions were evaluated for 25 patients on maintenance HD. Concentrations of phosphate, urea and creatinine in plasma were measured every 1h during the treatment and 45 min after, and every 30 min in dialysate. ECC was calculated using the removed solute mass assessed in dialysate and weekly solute profile in plasma. Similar calculations were performed also for the midweek dialysis session only. Different versions of the reference concentration for ECC were applied. ECC with peak average reference concentration was 5.4 ± 1.0 for phosphate, 7.0 ± 1.0 for urea and 4.7 ± 1.0 mL/min for creatinine. ECC for urea and creatinine were well correlated in contrast to the correlations of ECC for phosphate versus urea and creatinine. Midweek ECC were higher than weekly ECC, but they were well correlated for urea and creatinine, but only weakly for phosphate. HD adequacy monitoring for phosphate may be performed using ECC, but it is less predictable than similar indices for urea and creatinine. The values of ECC for phosphate are within the range expected for its molecular size compared with those for urea and creatinine. © The Author 2014. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  14. Use of a knowledge-attitude-behaviour education programme for Chinese adults undergoing maintenance haemodialysis: Randomized controlled trial.

    PubMed

    Liu, Li; Liu, Yue-Ping; Wang, Jing; An, Li-Wei; Jiao, Jian-Mei

    2016-06-01

    To investigate the effects of a knowledge-attitude-behaviour health education model on acquisition of disease-related knowledge and self-management behaviour by patients undergoing maintenance haemodialysis. Patients recently prescribed MHD were randomly assigned to a control group or an intervention group. Control group patients were treated with usual care and general education models. A specialist knowledge-attitude-behaviour health education model was applied to patients in the intervention group. Eighty-six patients were included (n = 43 per group). Before intervention, there were no significant between-group differences in disease knowledge and self-management behaviour. After 6 months' intervention, a significant between-group difference in acquisition of disease knowledge was observed. Self-management behaviour scores (control of body mass, reasonable diet, correct drug intake, physical activity, correct fistula care, disease condition monitoring, psychological and social behaviours) for the intervention group were also higher than those for the control group. These preliminary findings suggest that the knowledge-attitude-behaviour model appears to be a valuable tool for the health education of MHD patients. © The Author(s) 2016.

  15. Use of a knowledge-attitude-behaviour education programme for Chinese adults undergoing maintenance haemodialysis: Randomized controlled trial

    PubMed Central

    Liu, Li; Wang, Jing; An, Li-Wei; Jiao, Jian-Mei

    2016-01-01

    Objective To investigate the effects of a knowledge-attitude-behaviour health education model on acquisition of disease-related knowledge and self-management behaviour by patients undergoing maintenance haemodialysis. Methods Patients recently prescribed MHD were randomly assigned to a control group or an intervention group. Control group patients were treated with usual care and general education models. A specialist knowledge-attitude-behaviour health education model was applied to patients in the intervention group. Results Eighty-six patients were included (n = 43 per group). Before intervention, there were no significant between-group differences in disease knowledge and self-management behaviour. After 6 months’ intervention, a significant between-group difference in acquisition of disease knowledge was observed. Self-management behaviour scores (control of body mass, reasonable diet, correct drug intake, physical activity, correct fistula care, disease condition monitoring, psychological and social behaviours) for the intervention group were also higher than those for the control group. Conclusion These preliminary findings suggest that the knowledge-attitude-behaviour model appears to be a valuable tool for the health education of MHD patients. PMID:26951842

  16. Improving distress in dialysis (iDiD): a feasibility two-arm parallel randomised controlled trial of an online cognitive behavioural therapy intervention with and without therapist-led telephone support for psychological distress in patients undergoing haemodialysis.

    PubMed

    Hudson, Joanna L; Moss-Morris, Rona; Game, David; Carroll, Amy; McCrone, Paul; Hotopf, Matthew; Yardley, Lucy; Chilcot, Joseph

    2016-04-12

    Psychological distress is common in end-stage kidney disease (ESKD) and is associated with poorer health outcomes. Cognitive behavioural therapy (CBT) is recommended in UK clinical guidelines for the management of depression in people with long-term conditions. Access to skilled therapists competent in managing the competing mental and physical health demands of ESKD is limited. Online CBT treatments tailored to the needs of the ESKD population offers a pragmatic solution for under-resourced services. This study examines the feasibility and acceptability of implementing a two-arm parallel randomised controlled trial of online CBT with (intervention arm) and without (control arm) therapist support to improve psychological distress in patients undergoing haemodialysis. Patients will be screened for depression and anxiety while attending for their haemodialysis treatments. We aim to recruit 60 adult patients undergoing haemodialysis who meet criteria for mild to moderately severe symptoms of depression and/or anxiety. Patients will be randomised individually (using a 1:1 computerised sequence ratio) to either online CBT with therapist telephone support (intervention arm), or online CBT with no therapist (control arm). Outcomes include feasibility and acceptability descriptive data on rates of recruitment, randomisation, retention and treatment adherence. Self-report outcomes include measures of depression (Patient Health Questionnaire-9), anxiety (Generalised Anxiety Disorder-7), quality of life (Euro-QoL), service use (client service receipt inventory) and illness cognitions (brief illness perception questionnaire). A qualitative process evaluation will also be conducted. The statistician will be blinded to treatment allocation. A National Health Service (NHS) research ethics committee approved the study. Data from this study will provide essential information for the design and testing of further interventions to ameliorate distress in patients undergoing dialysis

  17. The next of kin of older people undergoing haemodialysis: a discursive perspective on perceptions of participation.

    PubMed

    Aasen, Elin Margrethe; Kvangarsnes, Marit; Wold, Bente; Heggen, Kåre

    2012-08-01

    This paper is a report of a study conducted to explore how the family members of older people who will undergo haemodialysis treatment for the rest of their lives perceive participation. The rights of families to participate in treatment and health care are supported by international law, and by national law in Norway since 1999. This study, which employed an explorative qualitative approach, was carried out in Norway in 2008. Data were derived from transcribed interviews with seven family members underwent critical discourse analysis. Three discourse practices about the next of kin perception of participation were found: (1) to care and take control, (2) to struggle for involvement, and (3) to be forgotten and powerless. The next of kin said that they had no dialogue with the healthcare team, and some fought to be included in the decision-making process. The dominant part of the discourse as expressed by the next of kin seems to be a paternalistic ideology. Thus, finding ways to enable the next of kin to participate in the decision-making process seems to be a major challenge for the healthcare team in the dialysis units. © 2011 Blackwell Publishing Ltd.

  18. Aquatic Equipment Information.

    ERIC Educational Resources Information Center

    Sova, Ruth

    Equipment usually used in water exercise programs is designed for variety, intensity, and program necessity. This guide discusses aquatic equipment under the following headings: (1) equipment design; (2) equipment principles; (3) precautions and contraindications; (4) population contraindications; and (5) choosing equipment. Equipment is used…

  19. Uncarboxylated matrix Gla protein (ucMGP) is associated with coronary artery calcification in haemodialysis patients.

    PubMed

    Cranenburg, Ellen C M; Brandenburg, Vincent M; Vermeer, Cees; Stenger, Melanie; Mühlenbruch, Georg; Mahnken, Andreas H; Gladziwa, Ulrich; Ketteler, Markus; Schurgers, Leon J

    2009-02-01

    Matrix gamma-carboxyglutamate (Gla) protein (MGP) is a potent local inhibitor of cardiovascular calcification and accumulates at areas of calcification in its uncarboxylated form (ucMGP). We previously found significantly lower circulating ucMGP levels in patients with a high vascular calcification burden. Here we report on the potential of circulating ucMGP to serve as a biomarker for vascular calcification in haemodialysis (HD) patients. Circulating ucMGP levels were measured with an ELISA-based assay in 40 HD patients who underwent multi-slice computed tomography (MSCT) scanning to quantify the extent of coronary artery calcification (CAC). The mean ucMGP level in HD patients (193 +/- 65 nM) was significantly lower as compared to apparently healthy subjects of the same age (441 +/- 97 nM; p < 0.001) and patients with rheumatoid arthritis (RA) without CAC (560 +/- 140 nM; p < 0.001). Additionally, ucMGP levels correlated inversely with CAC scores (r = -0.41; p = 0.009), and this correlation persisted after adjustment for age, dialysis vintage and high-sensitivity C-reactive protein (hs-CRP). Since circulating ucMGP levels are significantly and inversely correlated with the extent of CAC in HD patients, ucMGP may become a tool for identifying HD patients with a high probability of cardiovascular calcification.

  20. Clinicians’ and researchers’ perspectives on establishing and implementing core outcomes in haemodialysis: semistructured interview study

    PubMed Central

    Tong, Allison; Crowe, Sally; Gill, John S; Harris, Tess; Hemmelgarn, Brenda R; Manns, Braden; Pecoits-Filho, Roberto; Tugwell, Peter; van Biesen, Wim; Wang, Angela Yee Moon; Wheeler, David C; Winkelmayer, Wolfgang C; Gutman, Talia; Ju, Angela; O’Lone, Emma; Sautenet, Benedicte; Viecelli, Andrea; Craig, Jonathan C

    2018-01-01

    Objectives To describe the perspectives of clinicians and researchers on identifying, establishing and implementing core outcomes in haemodialysis and their expected impact. Design Face-to-face, semistructured interviews; thematic analysis. Stetting Twenty-seven centres across nine countries. Participants Fifty-eight nephrologists (42 (72%) who were also triallists). Results We identified six themes: reflecting direct patient relevance and impact (survival as the primary goal of dialysis, enabling well-being and functioning, severe consequences of comorbidities and complications, indicators of treatment success, universal relevance, stakeholder consensus); amenable and responsive to interventions (realistic and possible to intervene on, differentiating between treatments); reflective of economic burden on healthcare; feasibility of implementation (clarity and consistency in definition, easily measurable, requiring minimal resources, creating a cultural shift, aversion to intensifying bureaucracy, allowing justifiable exceptions); authoritative inducement and directive (endorsement for legitimacy, necessity of buy-in from dialysis providers, incentivising uptake); instituting patient-centredness (explicitly addressing patient-important outcomes, reciprocating trial participation, improving comparability of interventions for decision-making, driving quality improvement and compelling a focus on quality of life). Conclusions Nephrologists emphasised that core outcomes should be relevant to patients, amenable to change, feasible to implement and supported by stakeholder organisations. They expected core outcomes would improve patient-centred care and outcomes. PMID:29678992

  1. Highway Maintenance Equipment Operator. Miscellaneous Equipment. Training Materials.

    ERIC Educational Resources Information Center

    Perky, Sandra Dutreau; And Others

    This curriculum guide provides instructional materials to assist in training equipment operators in the safe and effective use of highway maintenance equipment. It includes six units of instruction covering the small, specialized equipment used in maintenance operations. Each unit of instruction consists of eight basic components: performance…

  2. Medical Issues: Equipment

    MedlinePlus

    ... support & care > living with sma > medical issues > equipment Equipment Individuals with SMA often require a range of ... you can submit an equipment pool request. Helpful Equipment The following is a list of equipment that ...

  3. Highway Maintenance Equipment Operator. Specialized Equipment. Training Materials.

    ERIC Educational Resources Information Center

    Perky, Sandra Dutreau; And Others

    This curriculum guide provides instructional materials to assist in training equipment operators in the safe and effective use of highway maintenance equipment. It includes 18 units of instruction covering the large equipment used in maintenance operations. Each unit of instruction consists of eight basic components: performance objectives,…

  4. Comparison of estimates of resting energy expenditure equations in haemodialysis patients.

    PubMed

    Hung, Rachel; Sridharan, Sivakumar; Farrington, Ken; Davenport, Andrew

    2017-04-21

    Waste products of metabolism accumulate in patients with chronic kidney disease, and require clearance by haemodialysis (HD). We wished to determine whether there was an association between resting energy expenditure (REE) and total energy expenditure (TEE) in HD patients and body composition. We determined REE by recently validated equations (CKD equation) and compared REE with that estimated by standard equations for REE, and TEE calculated from patient reported physical activity, in HD patients with corresponding body composition measured by dual energy X-ray absorptiometry (DEXA) scanning. We studied 107 patients, 69 male (64.5%), mean age 62.7 ± 15.1 years. The CKD equation REE was 72.5 ± 13.3 watts (W) and TEE 83.2 ± 9.7 W. There was a strong association between REE with body surface area (BSA) (r2 = 0.80), total soft lean and fat lean tissue mass (r2 = 0.69), body mass index (BMI) (r2 = 0.34), all p<0.001. REE estimated using the modified Harris Benedict, Mifflin St. Jeor, Katch McArdle, Bernstein and Robertson equations underestimated REE compared to the CKD equation. TEE was more strongly associated with BSA (r2 = 0.51), appendicular muscle mass (r2 = 0.42), than BMI (r2 = 0.15) all p<0.001.TEE was greater for those employed (104.9 ± 10.7 vs. 83.1 ± 12.3 W, p<0.001), and with no co-morbidity (88.7 ± 14.8 vs. 82.7 ± 12.3 W, p<0.05). Standard equations underestimate REE in HD patients compared to the CKD equation. TEE was greater in those with more skeletal muscle mass, in those who were employed and in those with the least co-morbidity. More metabolically active patients may well require greater dialytic clearances.

  5. Effects of rotigotine on clinical symptoms, quality of life and sleep hygiene adequacy in haemodialysis-associated restless legs syndrome.

    PubMed

    Esteve, Vicent; Carneiro, Jose; Salazar, Gabriel; Pou, Mónica; Tapia, Irati; Fulquet, Miquel; Duarte, Verónica; Saurina, Anna; Moreno, Fátima; Ramírez de Arellano, Manel

    Restless legs syndrome (RLS) is a neurological disorder characterised by bothersome symptoms associated with impaired quality of life and sleep hygiene. Rotigotine is a novel therapeutic alternative, although few studies have been published in patients on haemodialysis (HD) with RLS treated with rotigotine. 1.- To establish the prevalence of RLS in our HD unit. 2.- To evaluate the efficacy and safety profile of rotigotine and its effect on symptoms, quality of life and sleep hygiene in our HD population with RLS. A single-centre, 12-week prospective study. Two stages (6 weeks): stage 1 (no treatment) and stage 2 (rotigotine). We analysed: 1.- Demographic data, biochemistry data, HD suitability parameters and RLS medical treatment data. 2.- Lower extremity symptoms questionnaire (QS). 3.- RLS severity symptoms scale (SRLSS). 4.- RLS Quality of life: John Hopkins RLS-QoL (JH-QoL). 5.- Sleep hygiene: SCOPA Scale. We included 66 HD patients, 14 with RLS; 44.4% male, 70.2±9.9 years and 111.1±160.8 months on HD. And 22.9% RLS. Exclusively in stage 2, a significant improvement for QS (10±2.4 vs. 5.7±1.0), SRLSS (21±4 vs. 5.7±4.6), JH-QoL (22.1±4.4 vs. 4.3±4.0) and SCOPA (16±5.3 vs. 6.7±1.9) were observed. A 77.7 and 11.1%, showed partial (> 20%) and complete (> 80%) remission, respectively, while 55.5% achieved «zero» symptoms. Only one patient had gastrointestinal intolerance and none experienced augmentation effect. No changes in biochemical data, suitability for dialysis or medical treatment were found. The inter-group analysis showed a significant improvement in relation to QS, SRLSS, JH-QoL and SCOPA in stage 2. RLS showed a considerable prevalence in our HD unit. Rotigotine improved clinical symptoms, quality of life and sleep hygiene in RLS patients on HD and was found to be a safe drug with minimal side effects and total therapeutic compliance. Nevertheless, future studies should be performed to confirm the benefits of rotigotine in RLS patients on

  6. Regular exercise during haemodialysis promotes an anti-inflammatory leucocyte profile

    PubMed Central

    Dungey, Maurice; Young, Hannah M L; Churchward, Darren R; Burton, James O; Smith, Alice C

    2017-01-01

    Abstract Background Cardiovascular disease is the most common cause of mortality in haemodialysis (HD) patients and is highly predicted by markers of chronic inflammation. Regular exercise may have beneficial anti-inflammatory effects, but this is unclear in HD patients. This study assessed the effect of regular intradialytic exercise on soluble inflammatory factors and inflammatory leucocyte phenotypes. Methods Twenty-two HD patients from a centre where intradialytic cycling was offered thrice weekly and 16 HD patients receiving usual care volunteered. Exercising patients aimed to cycle for 30 min at rating of perceived exertion of ‘somewhat hard’. Baseline characteristics were compared with 16 healthy age-matched individuals. Physical function, soluble inflammatory markers and leucocyte phenotypes were assessed again after 6 months of regular exercise. Results Patients were less active than their healthy counterparts and had significant elevations in measures of inflammation [interleukin-6 (IL-6), C-reactive protein (CRP), tumour necrosis factor-α (TNF-α), intermediate and non-classical monocytes; all P < 0.001]. Six months of regular intradialytic exercise improved physical function (sit-to-stand 60). After 6 months, the proportion of intermediate monocytes in the exercising patients reduced compared with non-exercisers (7.58 ± 1.68% to 6.38 ± 1.81% versus 6.86 ± 1.45% to 7.88 ± 1.66%; P < 0.01). Numbers (but not proportion) of regulatory T cells decreased in the non-exercising patients only (P < 0.05). Training had no significant effect on circulating IL-6, CRP or TNF-α concentrations. Conclusions These findings suggest that regular intradialytic exercise is associated with an anti-inflammatory effect at a circulating cellular level but not in circulating cytokines. This may be protective against the increased risk of cardiovascular disease and mortality that is associated with chronic inflammation and elevated numbers

  7. Extensive bleeding during surgical treatment for gingival overgrowth in a patient on haemodialysis--a case report and review of the literature.

    PubMed

    Nishide, N; Nishikawa, T; Kanamura, N

    2005-12-01

    Before performing renal transplantation, a most important concern is to control any infection, including oral infections before transplantation. The bleeding diathesis of patients with uraemia is a significant clinical concern, especially when surgery is required. A 44-year-old female patient on haemodialysis was referred for evaluation of gingival overgrowth. The patient was planning a renal transplantation two months later. As the lesions were not considered successfully treatable before transplantation, a gingivectomy and teeth extraction was performed. In pre-operative examinations, an abnormal bleeding time was not detected and other coagulation tests were normal. Under general anaesthesia, 19 teeth were extracted and overgrown gingiva was removed. During the operation, extensive blood loss of 1650ml occurred and four units of concentrated red blood cells were transfused. This study suggests that patients with renal failure undergoing dental surgery require careful pre-surgical evaluation including assessment of their coagulation ability.

  8. Daily haemodialysis improves indices of protein glycation.

    PubMed

    Floridi, Ardesio; Antolini, Francesco; Galli, Francesco; Fagugli, Riccardo Maria; Floridi, Emanuela; Buoncristiani, Umberto

    2002-05-01

    Advanced glycation end-products (AGEs) accumulate in uraemia, regardless of hyperglycaemic conditions, and may contribute to the onset of some long-term complications, such as atherosclerosis, amyloidosis, and neurodegenerative processes. In this study, we compare a daily with a standard 3 times/week dialysis rhythm (DHD and SHD, respectively) in correcting some protein glycation indices in end-stage renal disease (ESRD) patients. Twenty-one normoglycaemic and 11 diabetic patients on chronic haemodialysis (HD) with low-flux dialysers were studied in a prospective protocol to compare two different dialysis schedules, namely: 4 h, 3 times/week (SHD) and 2 h, 6 times/week (DHD). The patients were studied before and after 6 months of DHD. To further check the effect of DHD on glycation parameters, 4 normoglycaemic HD patients were studied in a third step in which they returned for 3 months to the SHD rhythm. Also, 11 chronic renal failure (CRF) patients not yet on HD and 11 age- and sex-matched healthy controls were studied. A new HPLC method was used to measure the following glycation indexes on plasma: the early product furosine and the advanced products protein-bound and free pentosidine, and two heterogeneous classes of low molecular mass (LMM) AGE peptides. All the parameters studied showed an accumulation that worsened with the progression of renal failure (controls

  9. Anti-parathyroid treatment effectiveness and persistence in incident haemodialysis patients with secondary hyperparathyroidism.

    PubMed

    de Francisco, Angel Luis Martín; Gillespie, Iain Andrew; Gioni, Ioanna; Floege, Jürgen; Kronenberg, Florian; Marcelli, Daniele; Wheeler, David Collins; Froissart, Marc; Drueke, Tilman Bernhard

    2016-01-01

    Anti-parathyroid treatment initiation and discontinuation are important decisions in chronic haemodialysis (HD) patients, where pill burden is often excessive. The present study aimed to describe secondary hyperparathyroidism (sHPT) drug therapy changes in HD patients. Retrospective observational cohort study of incident European HD patients with sHPT who were prescribed calcitriol or alfacalcidol (alpha calcitriol), paricalcitol or cinacalcet. Treatment-naïve patients prescribed alpha calcitriol (N=2259), paricalcitol (N=1689) and cinacalcet (N=1245) were considered for analysis. Serum intact parathyroid hormone (iPTH) levels decreased post-initiation with all treatment modalities; serum calcium and phosphate levels increased in response to activated vitamin D derivatives but decreased with cinacalcet. Approximately one-third of alpha calcitriol and paricalcitol patients but less than one-quarter of cinacalcet patients discontinued treatment. Although the three groups had comparable serum iPTH control at the time of treatment discontinuation, they differed in terms of calcium and phosphate levels. Following discontinuation, the evolution of laboratory parameters differed by treatment modality: whilst iPTH increased for all three treatment groups, calcium and phosphate decreased in patients who were being treated with alpha calcitriol and paricalcitol at the time of discontinuation, and increased in those who had been treated with cinacalcet. In conditions of daily clinical practice, attaining and maintaining recommended biochemical control of sHPT appears to be more frequently achievable with cinacalcet than with activated vitamin D compounds. Copyright © 2015 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  10. Clinicians' and researchers' perspectives on establishing and implementing core outcomes in haemodialysis: semistructured interview study.

    PubMed

    Tong, Allison; Crowe, Sally; Gill, John S; Harris, Tess; Hemmelgarn, Brenda R; Manns, Braden; Pecoits-Filho, Roberto; Tugwell, Peter; van Biesen, Wim; Wang, Angela Yee Moon; Wheeler, David C; Winkelmayer, Wolfgang C; Gutman, Talia; Ju, Angela; O'Lone, Emma; Sautenet, Benedicte; Viecelli, Andrea; Craig, Jonathan C

    2018-04-20

    To describe the perspectives of clinicians and researchers on identifying, establishing and implementing core outcomes in haemodialysis and their expected impact. Face-to-face, semistructured interviews; thematic analysis. Twenty-seven centres across nine countries. Fifty-eight nephrologists (42 (72%) who were also triallists). We identified six themes: reflecting direct patient relevance and impact (survival as the primary goal of dialysis, enabling well-being and functioning, severe consequences of comorbidities and complications, indicators of treatment success, universal relevance, stakeholder consensus); amenable and responsive to interventions (realistic and possible to intervene on, differentiating between treatments); reflective of economic burden on healthcare; feasibility of implementation (clarity and consistency in definition, easily measurable, requiring minimal resources, creating a cultural shift, aversion to intensifying bureaucracy, allowing justifiable exceptions); authoritative inducement and directive (endorsement for legitimacy, necessity of buy-in from dialysis providers, incentivising uptake); instituting patient-centredness (explicitly addressing patient-important outcomes, reciprocating trial participation, improving comparability of interventions for decision-making, driving quality improvement and compelling a focus on quality of life). Nephrologists emphasised that core outcomes should be relevant to patients, amenable to change, feasible to implement and supported by stakeholder organisations. They expected core outcomes would improve patient-centred care and outcomes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. An exploration of the relationship between adherence with dietary sodium restrictions and health beliefs regarding these restrictions in Irish patients receiving haemodialysis for end-stage renal disease.

    PubMed

    Walsh, Ella; Lehane, Elaine

    2011-02-01

    To measure adherence levels with dietary restrictions in Irish patients with end-stage renal disease receiving haemodialysis and to explore the relationships between adherence with dietary sodium restrictions and health beliefs in relation to following these restrictions in this group. Non-adherence to medical regimes is an important healthcare issue and an ever-present problem, particularly in patients with a chronic illness. The literature revealed a lack of studies measuring adherence with the sodium component of the renal dietary restrictions and associated factors; despite the fact that adherence with sodium restrictions is essential to the optimal management of end-stage renal disease. Furthermore, despite increased emphasis on 'the patients' view' in healthcare no study to date has contextualised health beliefs and adherence in end-stage renal disease from an Irish perspective. A quantitative, descriptive, correlational design was employed using the Health Belief Model as a theoretical framework. A convenience sample (n = 79) was recruited from the haemodialysis units of a large hospital. Data were collected using self-report questionnaires. Data were analysed using descriptive and correlational statistics. Non-adherence with dietary restrictions was a problem among a proportion of the sample. Greater adherence levels with dietary sodium restrictions were associated with greater 'perceived benefits' and fewer 'perceived barriers.' For the Irish patient, beliefs in relation to following a low sodium diet significantly affected adherence levels with this diet. This is an important finding as delineating key beliefs, particularly key barriers, facilitates an increased understanding of non-adherence for nurses. These findings have implications for the care of patients with end-stage renal disease in that they can provide guidance in terms of developing interventions designed to improve adherence. © 2011 Blackwell Publishing Ltd.

  12. Increased matrix metalloproteinases as possible cause of osseoarticular tissue destruction in long-term haemodialysis and beta 2-microglobulin amyloidosis.

    PubMed

    Ohashi, K; Kawai, R; Hara, M; Okada, Y; Tachibana, S; Ogura, Y

    1996-04-01

    Immunolocalization of matrix metalloproteinases (MMPs) and tissue inhibitors of matrix metalloproteinases (TIMPs) in periarticular tissues of beta 2-microglobulin amyloidosis patients was investigated. MMP-1 (interstitial collagenase) the most strongly expressed of the MMPs, was localized in the synovial lining cells, mesenchymal cells in granulation tissue and nodular amyloid deposits, and chondrocytes within areas of cartilage erosion. Expression of MMP-1 was correlated with the degree of macrophage infiltration and synovial cell hyperplasia, but it was not correlated with the degree of amyloid deposition or haemodialysis period. Expression of MMP-1 appeared more intense than that of TIMP-1 and TIMP-2 in highly inflammatory cases. MMP-2 was mildly expressed in the interstitial fibroblasts and MMP-3 was faintly stained in the extracellular matrix of the synovial membrane. MMP-9 (gelatinase B) was found to be strongly positive in the osteoclasts which increased in the progressing osteolytic lesion from the destructive arthropathy. These results suggest involvement of MMPs in inflammation with an imbalance between expression of MMPs and TIMPs being closely related to pathogenesis of the destructive arthropathy.

  13. Predictors of protein-energy wasting in haemodialysis patients: a cross-sectional study.

    PubMed

    Ruperto, M; Sánchez-Muniz, F J; Barril, G

    2016-02-01

    Protein-energy wasting (PEW) is a highly prevalent condition in haemodialysis patients (HD). The potential usefulness of nutritional-inflammatory markers in the diagnosis of PEW in chronic kidney disease has not been established completely. We hypothesised that a combination of serum albumin, percentage of mid-arm muscle circumference and standard body weight comprises a better discriminator than either single marker of nutritional status in HD patients. A cross-sectional study was performed in 80 HD patients. Patients were categorised in two groups: well-nourished and PEW. Logistic regression analysis was applied to corroborate the reliability of the three markers of PEW with all the nutritional-inflammatory markers analysed. PEW was identified in 52.5% of HD patients. Compared with the well-nourished patients, PEW patients had lower body mass index, serum pre-albumin and body cell mass (all P < 0.001) and higher C-reactive protein (s-CRP) (P < 0.01). Logistic regression analyses showed that the combination of the three criteria were significantly related with s-CRP >1 mg dL(-1) , phase angle <4°, and serum pre-albumin <30 mg dL(-1) (all P < 0.05). Other indicators, such as lymphocytes <20% and Charlson comorbidity index, were significantly involved (both P < 0.01). A receiver operating characteristic curve (area under the curve) of 0.86 (P < 0.001) was found. The combined utilisation of serum albumin, percentage of mid-arm muscle circumference and standard body weight as PEW markers appears to be useful for nutritional-inflammatory status assessment and adds predictive value to the traditional indicators. Larger studies are needed to achieve the reliability of these predictor combinations and their cut-off values in HD patients and other populations. © 2014 The British Dietetic Association Ltd.

  14. Power Product Equipment Technician: Lawn and Garden Equipment. Teacher Edition. Student Version.

    ERIC Educational Resources Information Center

    Hilley, Robert

    This packet contains teacher and student editions for lawn and garden equipment repair and maintenance, intended for the preparation of power product equipment technicians. This publication contains four units: (1) introduction to lawn and garden equipment; (2) light-duty lawn and garden equipment; (3) heavy-duty lawn and garden equipment; and (4)…

  15. Personal protective equipment

    MedlinePlus

    ... medlineplus.gov/ency/patientinstructions/000447.htm Personal protective equipment To use the sharing features on this page, please enable JavaScript. Personal protective equipment is special equipment you wear to create a ...

  16. Common NICU Equipment

    MedlinePlus

    ... care unit (NICU) > Common NICU equipment Common NICU equipment E-mail to a friend Please fill in ... understand how they can help your baby. What equipment is commonly used in the NICU? Providers use ...

  17. Increased levels of serum matrix metalloproteinase-3 in haemodialysis patients with dialysis-related amyloidosis.

    PubMed

    Naganuma, Toshihide; Sugimura, Kazunobu; Uchida, Junji; Tashiro, Koichiro; Yoshimura, Rikio; Takemoto, Yoshiaki; Nakatani, Tatsuya

    2008-04-01

    It is recognized that matrix metalloproteinase-3 (MMP-3) is abundantly expressed in active rheumatoid synovium, and that serum level of MMP-3 is a useful marker for diagnosis of rheumatoid arthritis and for evaluation of prognosis in joint destruction. Little is known about serum MMP-3 levels in haemodialysis (HD) patients, and thus, the association between serum MMP-3 and dialysis-related amyloidosis (DRA) has yet to be elucidated. Serum levels of MMP-3 were measured by enzyme immunoassay in 150 HD patients, 90 without DRA and 60 with DRA, before HD. Simple regression analysis was performed to investigate the relationship between serum level of MMP-3 and clinical parameters, including age, HD duration, C-reactive protein and beta2 microglobulin (BMG). Serum levels of MMP-3 were significantly higher in HD patients with DRA than in HD patients without DRA (258.2 +/- 118.1 vs 201.5 +/- 98.4 pg/mL, P = 0.0017), and both levels were significantly higher than those of healthy subjects (45.6 +/- 13.4 pg/mL, P < 0.0001). Serum MMP-3 levels significantly correlated with serum levels of BMG (r = 0.197, P = 0.0164) and HD duration (r = 0.168, P = 0.0427). Moreover, serum MMP-3 levels significantly correlated with serum BMG levels in HD patients without DRA (r = 0.341, P = 0.0012), but not in HD patients with DRA. Our results suggest that matrix metalloproteinase activity increases in HD patients, which may be associated with BMG and DRA.

  18. Chewing gum and a saliva substitute alleviate thirst and xerostomia in patients on haemodialysis.

    PubMed

    Bots, Casper P; Brand, Henk S; Veerman, Enno C I; Korevaar, Johanna C; Valentijn-Benz, Marianne; Bezemer, Pieter D; Valentijn, Robert M; Vos, Pieter F; Bijlsma, Joost A; ter Wee, Piet M; Van Amerongen, Barbara M; Nieuw Amerongen, Arie V

    2005-03-01

    Most patients on haemodialysis (HD) have to maintain a fluid-restricted diet to prevent a high interdialytic weight gain (IWG). The prevalence of xerostomia (the feeling of a dry mouth) is higher in HD patients than in controls. Recently, we demonstrated that xerostomia and thirst were positively correlated with IWG in HD patients. Thus, this may play a role as a stimulus for fluid intake between dialysis sessions. The aim of the present study was to investigate the effect of chewing gum or a saliva substitute on xerostomia, thirst and IWG. This study was a randomized two-treatment crossover design with repeated measures. After the use of chewing gum or saliva substitute for 2 weeks, a wash-out period of 2 weeks was introduced and hereafter the other regimen was carried out. Xerostomia and thirst were assessed by validated questionnaires as xerostomia inventory (XI) and dialysis thirst inventory (DTI), at baseline and after each treatment period, as were IWG and salivary flow rates. Sixty-five HD patients (42 men, 54.6+/-14.1 years; 23 women, 54.7+/-16.3 years) participated in this study. Chewing gum decreased XI from 29.9+/-9.5 to 28.1+/-9.1 (P<0.05). Chewing gum as well as a saliva substitute reduced DTI significantly (P<0.05), but no differences occurred for the average IWG or salivary flow rates. The use of chewing gum and, to a lesser extent, a saliva substitute may alleviate thirst and xerostomia in some HD patients.

  19. Sex and gender differences in chronic kidney disease: progression to end-stage renal disease and haemodialysis.

    PubMed

    Cobo, Gabriela; Hecking, Manfred; Port, Friedrich K; Exner, Isabella; Lindholm, Bengt; Stenvinkel, Peter; Carrero, Juan Jesús

    2016-07-01

    Sex and gender differences are of fundamental importance in most diseases, including chronic kidney disease (CKD). Men and women with CKD differ with regard to the underlying pathophysiology of the disease and its complications, present different symptoms and signs, respond differently to therapy and tolerate/cope with the disease differently. Yet an approach using gender in the prevention and treatment of CKD, implementation of clinical practice guidelines and in research has been largely neglected. The present review highlights some sex- and gender-specific evidence in the field of CKD, starting with a critical appraisal of the lack of inclusion of women in randomized clinical trials in nephrology, and thereafter revisits sex/gender differences in kidney pathophysiology, kidney disease progression, outcomes and management of haemodialysis care. In each case we critically consider whether apparent discrepancies are likely to be explained by biological or psycho-socioeconomic factors. In some cases (a few), these findings have resulted in the discovery of disease pathways and/or therapeutic opportunities for improvement. In most cases, they have been reported as merely anecdotal findings. The aim of the present review is to expose some of the stimulating hypotheses arising from these observations as a preamble for stricter approaches using gender for the prevention and treatment of CKD and its complications. © 2016 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  20. The role of religion and spirituality in coping with kidney disease and haemodialysis in Thailand.

    PubMed

    Yodchai, Kantaporn; Dunning, Trisha; Savage, Sally; Hutchinson, Alison M

    2017-06-01

    People with chronic kidney disease (CKD) face various problems including psychological, socioeconomic and physical effects associated with CKD and its treatment. They need to develop strategies to help them cope with CKD and life challenges. Religion and spirituality are important coping strategies, but their role in helping people cope with CKD and haemodialysis (HD) in Thailand is relatively unknown. To investigate the role of religion and spirituality in coping with CKD and its treatment in Thailand. An exploratory, qualitative approach was undertaken using semistructured individual interviews. Purposive sampling was used to recruit participants. Face-to-face, in-depth individual interviews using open questions were conducted during January and February 2012. Interviews were audio-recorded and transcribed verbatim. Data were analysed using the framework method of qualitative data analysis. Twenty people receiving HD participated: age range 23-77 years, mean 53.7 (±16.38 SD). Ten were women. Participants reported use of religious and spiritual practices to cope with CKD and its treatment, including religious and spiritual explanations for developing CKD, karmic disease, making merit, reading Dharma books, praying and chanting to save life and making a vow to Pran-Boon. Religion and spirituality provide powerful coping strategies that can help Thai people with CKD overcome the associated distress and difficulties. Religion and spirituality cannot be separated in Thai culture because Thai people are both religious and spiritual. © 2016 Nordic College of Caring Science.

  1. Vitamin K antagonists in children with central venous catheter on chronic haemodialysis: a pilot study.

    PubMed

    Paglialonga, Fabio; Artoni, Andrea; Braham, Simon; Consolo, Silvia; Giannini, Alberto; Chidini, Giovanna; Napolitano, Luisa; Martinelli, Ida; Montini, Giovanni; Edefonti, Alberto

    2016-05-01

    To date, no study has investigated the use of vitamin K antagonists (VKA) in children undergoing chronic haemodialysis (HD) with a central venous catheter (CVC). Consecutive patients aged <18 years with a newly placed tunnelled CVC for chronic HD were enrolled over a 3-year period. Children with active nephrotic syndrome or a history of venous thrombosis received warfarin (VKA group) with therapeutic target international normalised ratios of between 2.0 and 3.0. Patients at standard risk of CVC malfunction were not treated with VKA (standard group). The primary end-point was overall CVC survival. The VKA group consisted of nine patients (median age 10.6 years; range 1.2-15.3 years) with 11 CVC, and the standard group comprised eight patients (11.8 years; 6.1-17.3 years) with ten CVC. The 6- and 12-month CVC survival was significantly longer in the VKA group than in the standard group (100 vs. 60 % and 83.3 vs. 16.7 %, respectively; p < 0.05), with a median survival of 369 and 195 days, respectively (p < 0.05). None of the CVC in the VKA group required removal due to malfunction, as compared to four in the standard group. No major bleeding episodes occurred in either group. Therapy with VKA would appear to be safe in children on chronic HD and may improve CVC survival in patients at increased risk of CVC thrombosis.

  2. Space processing applications payload equipment study. Volume 2E: Commercial equipment utility

    NASA Technical Reports Server (NTRS)

    Smith, A. G. (Editor)

    1974-01-01

    Examination of commercial equipment technologies revealed that the functional performance requirements of space processing equipment could generally be met by state-of-the-art design practices. Thus, an apparatus could be evolved from a standard item or derived by custom design using present technologies. About 15 percent of the equipment needed has no analogous commercial base of derivation and requires special development. This equipment is involved primarily with contactless heating and position control. The derivation of payloads using commercial equipment sources provides a broad and potentially cost-effective base upon which to draw. The derivation of payload equipment from commercial technologies poses other issues beyond that of the identifiable functional performance, but preliminary results on testing of selected equipment testing appear quite favorable. During this phase of the SPA study, several aspects of commercial equipment utility were assessed and considered. These included safety, packaging and structural, power conditioning (electrical/electronic), thermal and materials of construction.

  3. Cleaning supplies and equipment

    MedlinePlus

    ... gov/ency/patientinstructions/000443.htm Cleaning supplies and equipment To use the sharing features on this page, ... to clean supplies and equipment. Disinfecting Supplies and Equipment Start by wearing the right personal protective equipment ( ...

  4. Apolipoprotein A-IV concentrations and clinical outcomes in haemodialysis patients with type 2 diabetes mellitus--a post hoc analysis of the 4D Study.

    PubMed

    Kollerits, B; Krane, V; Drechsler, C; Lamina, C; März, W; Ritz, E; Wanner, C; Kronenberg, F

    2012-12-01

    Apolipoprotein A-IV (apoA-IV) is an anti-atherogenic and anti-oxidative plasma glycoprotein involved in reverse cholesterol transport. The aim of this study was to examine the association between apoA-IV and all-cause mortality, cardiovascular endpoints and parameters of protein-energy wasting and nutrition in haemodialysis patients. This post hoc analysis was performed in the German Diabetes Dialysis Study (4D Study) evaluating atorvastatin in 1255 haemodialysis patients with type 2 diabetes mellitus, followed for a median of 4 years. The association between apoA-IV and relevant outcomes was analysed using Cox proportional hazards regression analyses. Body mass index (BMI) was used as a marker of protein-energy wasting. In addition, a definition of extended wasting was applied, combining median values of BMI, serum albumin, creatinine and sensitive C-reactive protein, to classify patients. Mean (±SD) apoA-IV concentration was 49.8 ± 14.2 mg dL(-1). Age- and gender-adjusted apoA-IV concentrations were strongly associated with the presence of congestive heart failure at baseline [odds ratio = 0.81, 95% confidence interval (CI) 0.74-0.88 per 10 mg dL(-1) increase; P < 0.001). During the prospective follow-up, the strongest association was found for all-cause mortality [hazard ratio (HR) = 0.89, 95% CI 0.85-0.95, P = 0.001), which was mainly because of patients with BMI > 23 kg m(-2) (HR = 0.87, 95% CI 0.82-0.94, P < 0.001) and those in the nonwasting group according to the extended definition (HR = 0.89, 95% CI 0.84-0.96, P = 0.001). This association remained significant after additionally adjusting for parameters associated with apoA-IV at baseline. Further associations were observed for sudden cardiac death. ApoA-IV was less strongly associated with atherogenic events such as myocardial infarction. Low apoA-IV levels seem to be a risk predictor of all-cause mortality and sudden cardiac death. This association might be modified by nutritional status. © 2012 The

  5. Renewal of radiological equipment.

    PubMed

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  6. Why take the chance? A qualitative grounded theory study of nocturnal haemodialysis recipients who decline kidney transplantation

    PubMed Central

    Rosenthal, Meagen M; Molzahn, Anita E; Chan, Christopher T; Cockfield, Sandra L; Kim, S Joseph; Pauly, Robert P

    2016-01-01

    Objective The objective of this study was to examine the factors that influence decision-making to forgo transplantation in favour of remaining on nocturnal haemodialysis (NHD). Design A grounded theory approach using in-depth telephone interviewing was used. Setting Participants were identified from 2 tertiary care renal programmes in Canada. Participants The study participants were otherwise eligible patients with end-stage renal disease who have opted to remain off of the transplant list. A total of 7 eligible participants were interviewed. 5 were male. The mean age was 46 years. Analysis A constant comparative method of analysis was used to identify a core category and factors influencing the decision-making process. Results In this grounded theory study of people receiving NHD who refused kidney transplantation, the core category of ‘why take a chance when things are going well?’ was identified, along with 4 factors that influenced the decision including ‘negative past experience’, ‘feeling well on NHD’, ‘gaining autonomy’ and ‘responsibility’. Conclusions This study provides insight into patients' thought processes surrounding an important treatment decision. Such insights might help the renal team to better understand, and thereby respect, patient choice in a patient-centred care paradigm. Findings may also be useful in the development of education programmes addressing the specific concerns of this population of patients. PMID:27194322

  7. Hypothyroidism is associated with all-cause mortality in a national cohort of chronic haemodialysis patients.

    PubMed

    Lin, Hsuan-Jen; Lin, Chung-Chih; Lin, Hsuan Ming; Chen, Hsuan-Ju; Lin, Che-Chen; Chang, Chiz-Tzung; Chou, Che-Yi; Huang, Chiu-Ching

    2018-06-01

    The prevalence of hypothyroidism is high in haemodialysis (HD) patients and hypothyroidism increases all-cause mortality in HD patients. Comorbidities are common in HD patients and are associated with both mortality and hypothyroidism. The aim of the study is to explore the effect of the interactions of comorbidities and hypothyroidism on all-cause mortality in HD patients. Patients with hypothyroidism (ICD-9-CM 244.0, 244.1, and 244.9) and matched patients without hypothyroidism in the Registry for Catastrophic Illness Patient Database of Taiwan Health Insurance from 2000 to 2010 were analyzed. The association of hypothyroidism and risk of all-cause mortality was analyzed using Cox proportional hazard regression. Nine hundred and eight HD patients with hypothyroidism and 3632 sex-, age-, gender- matched HD patients without hypothyroidism were analyzed. Hypothyroidism was associated with increased all-cause mortality with an adjusted hazard ratio of 1.22 [95% confidence interval (CI): 1.10-1.36, P < 0.001]. TRT may decrease mortality associated with hypothyroidism (P < 0.001). There was a significant interaction (P = 0.04) between diabetes and hypothyroidism. There was no significant interaction found in hypothyroidism and the following comorbidities: hyperlipidaemia, hypertension, chronic obstructive pulmonary disease, coronary artery disease, stroke, peripheral arterial disease, asthma, congestive heart failure and cancer. Hypothyroidism is associated with increased all-cause mortality in chronic HD patients. The interaction of hypothyroidism and diabetes, but not other common comorbidities in HD patients, has an effect on mortality risks. © 2017 Asian Pacific Society of Nephrology.

  8. A comparison of self-reported quality of life for an Australian haemodialysis and haemodiafiltration cohort.

    PubMed

    Hill, Kathleen E; Kim, Susan; Crail, Susan; Elias, Tony J; Whittington, Tiffany

    2017-08-01

    Haemodiafiltration (HDF) has been widely studied for evidence of superior outcomes in comparison with conventional haemodialysis (HD), and there is increasing interest in determining if HDF confers any benefit in relation to quality of life. Studies have been conducted with randomized incident patients; however, little is known regarding HDF and quality of life for prevalent patients. This study examined and compared self-reported quality of life at two time points, 12 months apart in a cohort of satellite HD and HDF patients, using a disease specific questionnaire to determine if HDF conferred an advantage. A longitudinal study with a linear mixed-effect model measuring quality of life in a cohort of 171 patients (HD, n = 85, HDF, n = 86) in seven South Australian satellite dialysis centres. Factors associated with significant reduction across the Kidney Disease Quality Of Life™ domains measured were younger age (- 20 to - 29) and comorbid diabetes (- 4.8 to - 11.1). HDF was not associated with moderation of this reduction at either time point (P > 0.05). Baseline physical functioning was reported as very low (median 33.9) and further reduced at time point two. In addition, dialysing for more than 12 h per week in a satellite dialysis unit was associated with reduced quality of life in relation to the burden of kidney disease (- 13.69). This study has demonstrated that younger age and comorbid diabetes were responsible for a statistically significant reduction in quality of life, and HDF did not confer any advantage. © 2016 Asian Pacific Society of Nephrology.

  9. Peripheral i.v. analysis (PIVA) of venous waveforms for volume assessment in patients undergoing haemodialysis.

    PubMed

    Hocking, K M; Alvis, B D; Baudenbacher, F; Boyer, R; Brophy, C M; Beer, I; Eagle, S

    2017-12-01

    The assessment of intravascular volume status remains a challenge for clinicians. Peripheral i.v. analysis (PIVA) is a method for analysing the peripheral venous waveform that has been used to monitor volume status. We present a proof-of-concept study for evaluating the efficacy of PIVA in detecting changes in fluid volume. We enrolled 37 hospitalized patients undergoing haemodialysis (HD) as a controlled model for intravascular volume loss. Respiratory rate (F0) and pulse rate (F1) frequencies were measured. PIVA signal was obtained by fast Fourier analysis of the venous waveform followed by weighing the magnitude of the amplitude of the pulse rate frequency. PIVA was compared with peripheral venous pressure and standard monitoring of vital signs. Regression analysis showed a linear correlation between volume loss and change in the PIVA signal (R2=0.77). Receiver operator curves demonstrated that the PIVA signal showed an area under the curve of 0.89 for detection of 20 ml kg-1 change in volume. There was no correlation between volume loss and peripheral venous pressure, blood pressure or pulse rate. PIVA-derived pulse rate and respiratory rate were consistent with similar numbers derived from the bio-impedance and electrical signals from the electrocardiogram. PIVA is a minimally invasive, novel modality for detecting changes in fluid volume status, respiratory rate and pulse rate in spontaneously breathing patients with peripheral i.v. cannulas. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  10. Hepcidin-25 is related to cardiovascular events in chronic haemodialysis patients.

    PubMed

    van der Weerd, Neelke C; Grooteman, Muriel P C; Bots, Michiel L; van den Dorpel, Marinus A; den Hoedt, Claire H; Mazairac, Albert H A; Nubé, Menso J; Penne, E Lars; Wetzels, Jack F M; Wiegerinck, Erwin T; Swinkels, Dorine W; Blankestijn, Peter J; Ter Wee, Piet M

    2013-12-01

    The development of atherosclerosis may be enhanced by iron accumulation in macrophages. Hepcidin-25 is a key regulator of iron homeostasis, which downregulates the cellular iron exporter ferroportin. In haemodialysis (HD) patients, hepcidin-25 levels are increased. Therefore, it is conceivable that hepcidin-25 is associated with all-cause mortality and/or fatal and non-fatal cardiovascular (CV) events in this patient group. The aim of the current analysis was to study the relationship between hepcidin-25 and all-cause mortality and both fatal and non-fatal CV events in chronic HD patients. Data from 405 chronic HD patients included in the CONvective TRAnsport STudy (NCT00205556) were studied (62% men, age 63.7 ± 13.9 years [mean ± SD]). The median (range) follow-up was 3.0 (0.8-6.6) years. Hepcidin-25 was measured with mass spectrometry. The relationship between hepcidin-25 and all-cause mortality or fatal and non-fatal CV events was investigated with multivariate Cox proportional hazard models. Median (interquartile range) hepcidin-25 level was 13.8 (6.6-22.5) nmol/L. During follow-up, 158 (39%) patients died from any cause and 131 (32%) had a CV event. Hepcidin-25 was associated with all-cause mortality in an unadjusted model [hazard ratio (HR) 1.14 per 10 nmol/L, 95% CI 1.03-1.26; P = 0.01], but not after adjustment for all confounders including high-sensitive C-reactive protein (HR 1.02 per 10 nmol/L, 95% CI 0.87-1.20; P = 0.80). At the same time, hepcidin-25 was significantly related to fatal and non-fatal CV events in a fully adjusted model (HR 1.24 per 10 nmol/L, 95% CI 1.05-1.46, P = 0.01). Hepcidin-25 was associated with fatal and non-fatal CV events, even after adjustment for inflammation. Furthermore, inflammation appears to be a significant confounder in the relation between hepcidin-25 and all-cause mortality. These findings suggest that hepcidin-25 might be a novel determinant of CV disease in chronic HD patients.

  11. Listing of Food Service Equipment.

    ERIC Educational Resources Information Center

    National Sanitation Foundation, Ann Arbor, MI. Testing Lab.

    A comprehensive listing of food service equipment including--(1) companies authorized to use the National Sanitation Foundation seal of approval, and (2) equipment listed as meeting NSF standards including soda fountains, spray-type dishwashers, dishwashing equipment, cooking equipment, commerical cooking and warming equipment, freezers,…

  12. Hyperbaric Chamber Equipment: A Consolidated Equipment List from Selected Multiplace Hyperbaric Facilities.

    DTIC Science & Technology

    1983-12-01

    carbon dioxide scrubbers , air conditioning, communications, lighting, and fire detecting and fire extinguishing systems. Medical support equipment was...10 14 Humidity...............................11 5. Hydrocarb on...........................11 B. Carbon Dioxide Scrubbers .....................11 C...and ancillary equipment included gas/vapor monitoring equipment, carbon dioxide scrubbers , air conditioning, communications, lighting, and fire

  13. EPA’s Response Equipment

    EPA Pesticide Factsheets

    EPA maintains a variety of equipment to respond to hazardous substance emergencies such as releases or oil spills regardless of their nature, size, or location. This include ASPECT, PHILIS, Equipment Module (EM), and personal protective equipment.

  14. Prevalence of adherence to fluid restriction in kidney patients in haemodialysis: objective indicator and perceived compliance.

    PubMed

    Iborra-Moltó, Carmelo; López-Roig, Sofía; Pastor-Mira, M de Los Ángeles

    2012-07-17

    Studies of adherence to fluid restriction show high variability in prevalence data, as different methods of measuring IWG (interdialysis weight gain) and cut-off criteria are used. To describe the prevalence of adherence to fluid restriction using daily IWG (criterion: ≤1 Kg) and daily IWG adjusted for dry weight (DW) (cut-off point adjusted criterion: DW<70 kg, IWG=1 kg/day; DW>70 kg and ≤80 kg, IWG=1.1 kg/day; DW>80 kg and ≤90 kg, IWG=1.2 kg/day; DW>90 kg, IWG=1.3 kg/day) and to study the association between this objective indicator and adherence behaviour as reported by patient. Our study included a total of 146 patients with a mean age of 66 years (SD: 13.6 years; range: 25-88 years), 66% of which were male. Ours was a longitudinal study with one month of follow-up. We collected both sociodemographic and clinical variables and mean daily IWG. Patient-reported adherence behaviour was assessed through an interview by a trained staff member from outside the department who asked the following question: "In order to avoid complications between haemodialysis sessions: during the last month, how many days did you ingest less than 1 litre of fluid per day?" (0= no days; 10= every day). A score ≤5 led to categorisation of patients as compliant with treatment. Statistical analysis included descriptive analysis, correlation test, chi-square and Crosstabs, ROC curve and logistic regression procedures. Prevalence of "objective" adherence to fluid restriction was 61% (mean daily IWG≤1kg) and 73% (mean daily IWG adjusted for dry weight). Reported adherence (prevalence: 56.2%) was associated with IWG adjusted for weight (chi-square =31.34; P=.000). In patients with objective adherence adjusted for weight, the prevalence of reported adherence was 1.65 times that of non-adherence (PR=1.65; 95% CI: 1.29-2.11). The final model for estimating the association between reported adherence behaviour and daily adjusted IWG included: age (higher), dry weight (lower), potassium

  15. How to set the stage for a full-fledged clinical trial testing 'incremental haemodialysis'.

    PubMed

    Casino, Francesco Gaetano; Basile, Carlo

    2017-07-21

    Most people who make the transition to maintenance haemodialysis (HD) therapy are treated with a fixed dose of thrice-weekly HD (3HD/week) regimen without consideration of their residual kidney function (RKF). The RKF provides an effective and naturally continuous clearance of both small and middle molecules, plays a major role in metabolic homeostasis, nutritional status and cardiovascular health, and aids in fluid management. The RKF is associated with better patient survival and greater health-related quality of life. Its preservation is instrumental to the prescription of incremental (1HD/week to 2HD/week) HD. The recently heightened interest in incremental HD has been hindered by the current limitations of the urea kinetic model (UKM), which tend to overestimate the needed dialysis dose in the presence of a substantial RKF. A recent paper by Casino and Basile suggested a variable target model (VTM), which gives more clinical weight to the RKF and allows less frequent HD treatments at lower RKF as opposed to the fixed target model, based on the wrong concept of the clinical equivalence between renal and dialysis clearance. A randomized controlled trial (RCT) enrolling incident patients and comparing incremental HD (prescribed according to the VTM) with the standard 3HD/week schedule and focused on hard outcomes, such as survival and health-related quality of life of patients, is urgently needed. The first step in designing such a study is to compute the 'adequacy lines' and the associated fitting equations necessary for the most appropriate allocation of the patients in the two arms and their correct and safe follow-up. In conclusion, the potentially important clinical and financial implications of the incremental HD render it highly promising and warrant RCTs. The UKM is the keystone for conducting such studies. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  16. Atrial fibrillation in patients on haemodialysis in Andalusia. Prevalence, clinical profile and therapeutic management.

    PubMed

    Sánchez Perales, Carmen; Vázquez Sánchez, Teresa; Salas Bravo, Daniel; Ortega Anguiano, Sonia; Vázquez Ruiz de Castroviejo, Eduardo

    Atrial fibrillation (AF) represents an important social and healthcare problem. There is wide variability in the prevalence of this arrhythmia in studies analysing patients on haemodialysis (HD). To investigate the prevalence, clinical profile and therapeutic management of patients with AF on HD in Andalusia. We asked the public healthcare system of Andalusia to provide us with the number of patients who were being treated with HD. We asked attending nephrologists from all hospital and outpatient centres in 5 of the 8 Andalusian provinces to perform an electrocardiogram and to fill out a questionnaire on patients selected by simple random sampling. A total of 2,348 patients were being treated with HD in the 5provinces included in the study. The estimated sample size was 285 patients. We obtained an electrocardiogram and information from 252 patients (88.4%); mean age 65.3±16 years; 40.9% women. Sixty-three patients (25%) had AF. Of these, 36 (14.3%) had AF in the recorded ECG and in the rest it had been documented previously. In the multivariate analysis, older age (OR: 1.071; 95% CI: 1.036-1.107; P=0.000) and greater time on HD (OR: 1.009; 95% CI: 1.004-1.014; P=0.000) were independently associated with the presence of AF. Of the patients with AF, 41.3% were on anticoagulant treatment at the time of the study; and 41.2% were on antiplatelet agents. AF in dialysis units is an important finding. Establishing the risk-benefit ratio of anticoagulant treatment constitutes a real challenge. Well-designed clinical trials are pivotal in order to define the rational use of antithrombotic drugs. Copyright © 2017 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  17. Japanese haemodialysis anaemia management practices and outcomes (1999–2006): results from the DOPPS

    PubMed Central

    Akizawa, Tadao; Pisoni, Ronald L.; Akiba, Takashi; Saito, Akira; Fukuhara, Shunichi; Asano, Yasushi; Hasegawa, Takeshi; Port, Friedrich K.; Kurokawa, Kiyoshi

    2008-01-01

    Background. Japanese haemodialysis (HD) patients not only have a very low mortality and hospitalization risk but also low haemoglobin (Hb) levels. Internationally, anaemia is associated with mortality, hospitalization and health-related quality of life (QoL) measures of HD patients. Methods. Longitudinal data collected from 1999 to 2006 from 60 to 64 representative Japanese dialysis units participating in the Dialysis Outcomes and Practice Patterns Study (DOPPS) were used to describe anaemia management practices and outcomes for Japanese HD patients. Results. From 1999 to 2006, patient mean Hb increased from 9.7 g/dl to 10.4 g/dl, and the percentage of facilities with median Hb ≥10 g/dl increased from 27% to 75%. Hb was measured in the supine position for 90% of patients, resulting in substantially lower reported Hb values than those seen in other countries. As of 2006, erythropoietin (Epo) was prescribed to 83% of HD patients; mean Epo dose was 5231 units/week; intravenous (IV) iron use was 33% and median IV iron dose was 160 mg/month. Many patient- and facility-level factors were significantly related to higher Hb. A consistent overall pattern of lower mortality risk with higher baseline Hb levels was seen (RR = 0.89 per 1 g/dl higher Hb, P = 0.003). Facilities with median Hb ≥10.4 displayed a lower mortality risk (RR = 0.77, P = 0.03) versus facility median Hb <10.4 g/dl. Lower Hb levels were not significantly related to hospitalization risk, but were associated with lower QoL scores. Conclusions. These results provide detailed information on anaemia management practices in Japan and the relationships of anaemia control with outcomes, with implications of anaemia management worldwide. PMID:18577535

  18. Exercise Equipment: Neutral Buoyancy

    NASA Technical Reports Server (NTRS)

    Shackelford, Linda; Valle, Paul

    2016-01-01

    Load Bearing Equipment for Neutral Buoyancy (LBE-NB) is an exercise frame that holds two exercising subjects in position as they apply counter forces to each other for lower extremity and spine loading resistance exercises. Resistance exercise prevents bone loss on ISS, but the ISS equipment is too massive for use in exploration craft. Integrating the human into the load directing, load generating, and motion control functions of the exercise equipment generates safe exercise loads with less equipment mass and volume.

  19. Nutrition and dietary intake and their association with mortality and hospitalisation in adults with chronic kidney disease treated with haemodialysis: protocol for DIET-HD, a prospective multinational cohort study.

    PubMed

    Palmer, Suetonia C; Ruospo, Marinella; Campbell, Katrina L; Garcia Larsen, Vanessa; Saglimbene, Valeria; Natale, Patrizia; Gargano, Letizia; Craig, Jonathan C; Johnson, David W; Tonelli, Marcello; Knight, John; Bednarek-Skublewska, Anna; Celia, Eduardo; Del Castillo, Domingo; Dulawa, Jan; Ecder, Tevfik; Fabricius, Elisabeth; Frazão, João Miguel; Gelfman, Ruben; Hoischen, Susanne Hildegard; Schön, Staffan; Stroumza, Paul; Timofte, Delia; Török, Marietta; Hegbrant, Jörgen; Wollheim, Charlotta; Frantzen, Luc; Strippoli, G F M

    2015-03-20

    Adults with end-stage kidney disease (ESKD) treated with haemodialysis experience mortality of between 15% and 20% each year. Effective interventions that improve health outcomes for long-term dialysis patients remain unproven. Novel and testable determinants of health in dialysis are needed. Nutrition and dietary patterns are potential factors influencing health in other health settings that warrant exploration in multinational studies in men and women treated with dialysis. We report the protocol of the "DIETary intake, death and hospitalisation in adults with end-stage kidney disease treated with HaemoDialysis (DIET-HD) study," a multinational prospective cohort study. DIET-HD will describe associations of nutrition and dietary patterns with major health outcomes for adults treated with dialysis in several countries. DIET-HD will recruit approximately 10,000 adults who have ESKD treated by clinics administered by a single dialysis provider in Argentina, France, Germany, Hungary, Italy, Poland, Portugal, Romania, Spain, Sweden and Turkey. Recruitment will take place between March 2014 and June 2015. The study has currently recruited 8000 participants who have completed baseline data. Nutritional intake and dietary patterns will be measured using the Global Allergy and Asthma European Network (GA(2)LEN) food frequency questionnaire. The primary dietary exposures will be n-3 and n-6 polyunsaturated fatty acid consumption. The primary outcome will be cardiovascular mortality and secondary outcomes will be all-cause mortality, infection-related mortality and hospitalisation. The study is approved by the relevant Ethics Committees in participating countries. All participants will provide written informed consent and be free to withdraw their data at any time. The findings of the study will be disseminated through peer-reviewed journals, conference presentations and to participants via regular newsletters. We expect that the DIET-HD study will inform large pragmatic

  20. Listeria faecal carriage by renal transplant recipients, haemodialysis patients and patients in general practice: its relation to season, drug therapy, foreign travel, animal exposure and diet.

    PubMed Central

    MacGowan, A. P.; Marshall, R. J.; MacKay, I. M.; Reeves, D. S.

    1991-01-01

    About 2.3% (16/700) of faecal specimens from renal transplant recipients and patients having home haemodialysis as well as patients attending their general practitioners with symptoms of gastroenteritis yielded Listeria species 40% of positive faeces contained more than one Listeria species or serovar. The proportion of positive specimens was similar in all three patient groups. Listeria were isolated from 5.6% (10/177) of renal transplant recipients on one or more occasions over the period of a year. The commonest species was L. monocytogenes and type 4b the commonest serovar. Carriage was more common in July and August than other times of year, and less than 28 weeks in duration. In renal transplant recipients carriage was positively related to treatment with ranitidine, consumption of more than three types of cheese in the previous 20 months, and consumption of English cheddar cheese more than once per week. PMID:1993449

  1. 21 CFR 225.30 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... CURRENT GOOD MANUFACTURING PRACTICE FOR MEDICATED FEEDS Construction and Maintenance of Facilities and Equipment § 225.30 Equipment. (a) Equipment which is designed to perform its intended function and is properly installed and used is essential to the manufacture of medicated feeds. Such equipment permits...

  2. 23 CFR 140.910 - Equipment.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 23 Highways 1 2011-04-01 2011-04-01 false Equipment. 140.910 Section 140.910 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PAYMENT PROCEDURES REIMBURSEMENT Reimbursement for Railroad Work § 140.910 Equipment. (a) Company owned equipment. Cost of company-owned equipment may be...

  3. 23 CFR 140.910 - Equipment.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 23 Highways 1 2014-04-01 2014-04-01 false Equipment. 140.910 Section 140.910 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PAYMENT PROCEDURES REIMBURSEMENT Reimbursement for Railroad Work § 140.910 Equipment. (a) Company owned equipment. Cost of company-owned equipment may be...

  4. 23 CFR 140.910 - Equipment.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 23 Highways 1 2013-04-01 2013-04-01 false Equipment. 140.910 Section 140.910 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PAYMENT PROCEDURES REIMBURSEMENT Reimbursement for Railroad Work § 140.910 Equipment. (a) Company owned equipment. Cost of company-owned equipment may be...

  5. 23 CFR 140.910 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false Equipment. 140.910 Section 140.910 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PAYMENT PROCEDURES REIMBURSEMENT Reimbursement for Railroad Work § 140.910 Equipment. (a) Company owned equipment. Cost of company-owned equipment may be...

  6. Endovascular Treatment of Haemodialysis Arteriovenous Fistula with Drug-Coated Balloon Angioplasty: A Single-Centre Study.

    PubMed

    Lučev, Jernej; Breznik, Silva; Dinevski, Dejan; Ekart, Robert; Rupreht, Mitja

    2018-06-01

    To evaluate the effect of percutaneous transluminal angioplasty (PTA) on haemodialysis fistulas utilising drug-coated balloons with plain balloon vessel preparation (DCB). In the study group, 31 patients (16 men; mean age 62.8 ± 17.2 years) with failing arteriovenous fistulas were treated, with DCB, and compared with a control group (31 patients; 15 men; mean age 67.0 ± 8.44 years), in which only plain balloon PTA was performed. All stenoses were dilated with regular PTA balloons. After achieving haemodynamic success (< 30% residual stenosis), drug-coated balloons were used for drug administration in the study group. The follow-up intervals were 6, 12 and 24 months. Target lesion primary patency, primary assisted patency and secondary patency were compared. The statistical significance was set at 0.05. Target lesion primary patency was compared in both groups and was significantly higher in the study group (DCB) at 6 months (90.3 vs. 61.3%; p = 0.016), 12 months (77.4 vs. 29%; p = 0.0004) as well as 24 months (45.2 vs. 16.1%; p = 0.026). Kaplan-Meier survival curves also showed a significant difference for target lesion primary patency (534.2 vs. 315.7 days; p = 0.0004). There were no significant differences in target lesion primary assisted patency and in secondary patency. However, only 38.7% of patients in the study group were treated twice or more versus 80.6% in the control group (p = 0.002). DCB increases target lesion primary patency during the first 24 months and decreases the rate of reinterventions.

  7. DETECTION OF MALNUTRITION IN PATIENTS UNDERGOING MAINTENANCE HAEMODIALYSIS: A QUANTITATIVE DATA ANALYSIS ON 12 PARAMETERS.

    PubMed

    Nafzger, Sonja; Fleury, Lea-Angelica; Uehlinger, Dominik E; Plüss, Petra; Scura, Ninetta; Kurmann, Silvia

    2015-09-01

    Protein-energy-malnutrition (PEM) is common in people with end stage kidney disease (ESKD) undergoing maintenance haemodialysis (MHD) and correlates strongly with mortality. To this day, there is no gold standard for detecting PEM in patients on MHD. The aim of this study was to evaluate if Nutritional Risk Screening 2002 (NRS-2002), handgrip strength measurement, mid-upper arm muscle area (MUAMA), triceps skin fold measurement (TSF), serum albumin, normalised protein catabolic rate (nPCR), Kt/V and eKt/V, dry body weight, body mass index (BMI), age and time since start on MHD are relevant for assessing PEM in patients on MHD. The predictive value of the selected parameters on mortality and mortality or weight loss of more than 5% was assessed. Quantitative data analysis of the 12 parameters in the same patients on MHD in autumn 2009 (n = 64) and spring 2011 (n = 40) with paired statistical analysis and multivariate logistic regression analysis was performed. Paired data analysis showed significant reduction of dry body weight, BMI and nPCR. Kt/Vtot did not change, eKt/v and hand grip strength measurements were significantly higher in spring 2011. No changes were detected in TSF, serum albumin, NRS-2002 and MUAMA. Serum albumin was shown to be the only predictor of death and of the combined endpoint "death or weight loss of more than 5%". We now screen patients biannually for serum albumin, nPCR, Kt/V, handgrip measurement of the shunt-free arm, dry body weight, age and time since initiation of MHD. © 2015 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  8. Mobile Equipment Expands Inventory.

    ERIC Educational Resources Information Center

    McGough, Robert L.; And Others

    1978-01-01

    Describes the Mobile Equipment Modules (MEM) system in Duluth, Minnesota. MEM is a way to hold down costs and increase learning opportunities by consolidating purchases of expensive shop equipment within the school district, grouping the equipment in modules, and scheduling and moving it from school to school as needed. (MF)

  9. Why take the chance? A qualitative grounded theory study of nocturnal haemodialysis recipients who decline kidney transplantation.

    PubMed

    Rosenthal, Meagen M; Molzahn, Anita E; Chan, Christopher T; Cockfield, Sandra L; Kim, S Joseph; Pauly, Robert P

    2016-05-18

    The objective of this study was to examine the factors that influence decision-making to forgo transplantation in favour of remaining on nocturnal haemodialysis (NHD). A grounded theory approach using in-depth telephone interviewing was used. Participants were identified from 2 tertiary care renal programmes in Canada. The study participants were otherwise eligible patients with end-stage renal disease who have opted to remain off of the transplant list. A total of 7 eligible participants were interviewed. 5 were male. The mean age was 46 years. A constant comparative method of analysis was used to identify a core category and factors influencing the decision-making process. In this grounded theory study of people receiving NHD who refused kidney transplantation, the core category of 'why take a chance when things are going well?' was identified, along with 4 factors that influenced the decision including 'negative past experience', 'feeling well on NHD', 'gaining autonomy' and 'responsibility'. This study provides insight into patients' thought processes surrounding an important treatment decision. Such insights might help the renal team to better understand, and thereby respect, patient choice in a patient-centred care paradigm. Findings may also be useful in the development of education programmes addressing the specific concerns of this population of patients. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. A comparison of graft and patient outcomes following kidney transplantation in extended hour and conventional haemodialysis patients.

    PubMed

    See, Emily J; Hawley, Carmel M; Cho, Yeoungjee; Toussaint, Nigel D; Agar, John Wm; Pascoe, Elaine M; Lim, Wai H; Francis, Ross S; Collins, Michael G; Johnson, David W

    2018-01-08

    Differences in early graft function between kidney transplant recipients previously managed with either haemodialysis (HD) or peritoneal dialysis are well described. However, only two single-centre studies have compared graft and patient outcomes between extended hour and conventional HD patients, with conflicting results. This study compared the outcomes of all extended hour (≥24 hours/week) and conventional HD patients transplanted in Australia and New Zealand between 2000 and 2014. The primary outcome was delayed graft function (DGF), defined in an ordinal manner as either a spontaneous fall in serum creatinine of less than 10% within 24 hours, or the need for dialysis within 72 hours following transplantation. Secondary outcomes included the requirement for dialysis within 72 hours post-transplant, acute rejection, estimated glomerular filtration rate at 12 months, death-censored graft failure, all-cause and cardiovascular mortality, and a composite of graft failure and mortality. A total of 4,935 HD patients (378 extended hour HD, 4,557 conventional HD) received a kidney transplant during the study period. Extended hour HD was associated with an increased likelihood of DGF compared with conventional HD (adjusted proportional odds ratio 1.33; 95% confidence interval 1.06-1.67). There was no significant difference between extended hour and conventional HD in terms of any of the secondary outcomes. Compared to conventional HD, extended hour HD was associated with DGF, although long-term graft and patient outcomes were not different. This article is protected by copyright. All rights reserved.

  11. Approved Airport Equipment

    DOT National Transportation Integrated Search

    1997-06-06

    This advisory circular (AC) administratively cancels AC 150/5345-1U, Approved : Airport Equipment dated February 20, 1989, and directs replacement of any : reference to AC 150/5345-1 with AC 150/5345-53, Airport Lighting Equipment : Certification Pro...

  12. 141. ARAIII Equipment location plan. Includes list of equipment and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    141. ARA-III Equipment location plan. Includes list of equipment and location in reactor, control, and other buildings. Aerojet-general 880-area/GCRE-101-U-1. Date: February 1958. Ineel index code no. 063-0101-65-013-192508. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  13. VIEW OF ULTRASONIC TESTING EQUIPMENT IN BUILDING 991. THIS EQUIPMENT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF ULTRA-SONIC TESTING EQUIPMENT IN BUILDING 991. THIS EQUIPMENT NON-DESTRUCTIVELY TESTS WEAPONS COMPONENTS FOR FLAWS AND CRACKS. (9/11/85) - Rocky Flats Plant, Final Assembly & Shipping, Eastern portion of plant site, south of Spruce Avenue, east of Tenth Street & north of Central Avenue, Golden, Jefferson County, CO

  14. Power Product Equipment Technician: Equipment Systems. Teacher Edition. Student Edition.

    ERIC Educational Resources Information Center

    Hilley, Robert

    This packet contains teacher and student editions on the topic of equipment systems, intended for the preparation of power product equipment technicians. This publication contains seven units: (1) principles of power transmission; (2) mechanical drive systems; (3) principles of fluid power; (4) hydraulic and pneumatic drive systems; (5) wheel and…

  15. VALIDITY AND RELIABILITY OF THE SPIRITUAL COPING STRATEGIES SCALE ARABIC VERSION IN SAUDI PATIENTS UNDERGOING HAEMODIALYSIS.

    PubMed

    Cruz, Jonas P; Baldacchino, Donia R; Alquwez, Nahed

    2016-06-01

    Patients often resort to religious and spiritual activities to cope with physical and mental challenges. The effect of spiritual coping on overall health, adaptation and health-related quality of life among patients undergoing haemodialysis (HD) is well documented. Thus, it is essential to establish a valid and reliable instrument that can assess both the religious and non-religious coping methods in patients undergoing HD. This study aimed to assess the validity and reliability of the Spiritual Coping Strategies Scale Arabic version (SCS-A) in Saudi patients undergoing HD. A convenience sample of 60 Saudi patients undergoing HD was recruited for this descriptive, cross-sectional study. Data were collected between May and June 2015. Forward-backward translation was used to formulate the SCS-A. The SCS-A, Muslim Religiosity Scale and the Quality of Life Index Dialysis Version III were used to procure the data. Internal consistency reliability, stability reliability, factor analysis and construct validity tests were performed. Analyses were set at the 0.05 level of significance. The SCS-A showed an acceptable internal consistency and strong stability reliability over time. The EFA produced two factors (non-religious and religious coping). Satisfactory construct validity was established by the convergent and divergent validity and known-groups method. The SCS-A is a reliable and valid tool that can be used to measure the religious and non-religious coping strategies of patients undergoing HD in Saudi Arabia and other Muslim and Arabic-speaking countries. © 2016 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  16. Free-world microelectronic manufacturing equipment

    NASA Astrophysics Data System (ADS)

    Kilby, J. S.; Arnold, W. H.; Booth, W. T.; Cunningham, J. A.; Hutcheson, J. D.; Owen, R. W.; Runyan, W. R.; McKenney, Barbara L.; McGrain, Moira; Taub, Renee G.

    1988-12-01

    Equipment is examined and evaluated for the manufacture of microelectronic integrated circuit devices and sources for that equipment within the Free World. Equipment suitable for the following are examined: single-crystal silicon slice manufacturing and processing; required lithographic processes; wafer processing; device packaging; and test of digital integrated circuits. Availability of the equipment is also discussed, now and in the near future. Very adequate equipment for most stages of the integrated circuit manufacturing process is available from several sources, in different countries, although the best and most widely used versions of most manufacturing equipment are made in the United States or Japan. There is also an active market in used equipment, suitable for manufacture of capable integrated circuits with performance somewhat short of the present state of the art.

  17. 49 CFR 19.34 - Equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false Equipment. 19.34 Section 19.34 Transportation... Requirements Property Standards § 19.34 Equipment. (a) Title to equipment acquired by a recipient with Federal... use equipment acquired with Federal funds to provide services to non-Federal outside organizations for...

  18. 9 CFR 590.502 - Equipment and utensils; PCB-containing equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Equipment and utensils; PCB-containing equipment. 590.502 Section 590.502 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION INSPECTION OF EGGS AND EGG PRODUCTS (EGG PRODUCTS INSPECTION ACT) Sanitary, Processing, and Facilit...

  19. Medical equipment management strategies.

    PubMed

    Wang, Binseng; Furst, Emanuel; Cohen, Ted; Keil, Ode R; Ridgway, Malcolm; Stiefel, Robert

    2006-01-01

    Clinical engineering professionals need to continually review and improve their management strategies in order to keep up with improvements in equipment technology, as well as with increasing expectations of health care organizations. In the last 20 years, management strategies have evolved from the initial obsession with electrical safety to flexible criteria that fit the individual institution's needs. Few hospitals, however, are taking full advantage of the paradigm shift offered by the evolution of joint Commission standards. The focus should be on risks caused by equipment failure, rather than on equipment with highest maintenance demands. Furthermore, it is not enough to consider risks posed by individual pieces of equipment to individual patients. It is critical to anticipate the impact of an equipment failure on larger groups of patients, especially when dealing with one of a kind, sophisticated pieces of equipment that are required to provide timely and accurate diagnoses for immediate therapeutic decisions or surgical interventions. A strategy for incorporating multiple criteria to formulate appropriate management strategies is provided in this article.

  20. Adaptive Recreational Equipment.

    ERIC Educational Resources Information Center

    Schilling, Mary Lou, Ed.

    1983-01-01

    Designed for teachers interested in therapeutic recreation, the document lists sources of adaptive recreational equipment and their homemade counterparts. Brief descriptions for ordering or constructing recreational equipment for the visually impaired, poorly coordinated, physically impaired, and mentally retarded are given. Specific adaptations…

  1. 45 CFR 74.34 - Equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 1 2011-10-01 2011-10-01 false Equipment. 74.34 Section 74.34 Public Welfare... COMMERCIAL ORGANIZATIONS Post-Award Requirements Property Standards § 74.34 Equipment. (a) Title to equipment... section. (b)(1) The recipient shall not use equipment acquired with HHS funds to provide services to non...

  2. 43 CFR 12.934 - Equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Equipment. 12.934 Section 12.934 Public....934 Equipment. (a) Title to equipment acquired by a recipient with Federal funds shall vest in the recipient, subject to conditions of this section. (b) The recipient shall not use equipment acquired with...

  3. 45 CFR 74.34 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... equipment with a current per unit fair market value of $5000 or more, the recipient may retain the equipment... the original project or program to the current fair market value of the equipment. If the recipient... project or program to the current fair market value of the equipment, plus any reasonable shipping or...

  4. The pharmacokinetics of etanercept in patients with end-stage renal disease on haemodialysis.

    PubMed

    Don, Burl R; Spin, Gregory; Nestorov, Ivan; Hutmacher, Matt; Rose, Aubri; Kaysen, George A

    2005-11-01

    Inflammation is strongly associated with malnutrition and cardiovascular risk in patients with chronic renal failure on haemodialysis (HD). The acute-phase inflammatory response, defined by the increased synthesis of positive acute-phase proteins, is stimulated by the production of such cytokines as interleukin 6 (IL-6), interleukin 1 (IL-1) and tumour necrosis factor-alpha TNF-alpha The availability of cytokine antagonists allows testing of the hypothesis that suppression of inflammation reverses the malnutrition-inflammation syndrome in HD patients. Etanercept is a soluble TNF-alpha receptor fusion protein used to suppress inflammation in rheumatoid and psoriatic arthritis. Its metabolism in HD patients is unknown. In a study designed to test the safety and pharmacokinetics of etanercept in HD patients, etanercept was administered to six HD patients with albumin levels above 4.2 g dL(-1) and C-reactive protein levels <5 mg L(-1) (five men, one woman, age range 34-59 years). Etanercept (25 mg) was administered subcutaneously twice weekly immediately after dialysis for 13-16 weeks. Etanercept concentrations were measured pre- and post-dialysis by ELISA. Concentrations were compared graphically to assess whether, firstly, dialysis affects etanercept apparent clearance and, secondly, etanercept kinetics were similar between HD patients and the more extensively studied psoriasis population with normal renal function (PS). The second stage examined model-based parameter predictions of the terminal elimination rate constant (k) for HD patients. Steady-state etanercept levels were comparable between HD and PS patients. Treatment with HD had no effect on etanercept levels. When etanercept was discontinued, the terminal rate constant for HD patients was not significantly different from that observed in PS patients. No adverse effects were noted during the 3-month treatment phase and subsequent 6-month follow-up. Albumin and C-reactive protein levels did not change in these

  5. Overall Equipment Effectiveness Implementation Criteria

    NASA Astrophysics Data System (ADS)

    Abramova, I. G.; Abramov, D. A.

    2018-01-01

    This article documents the methods applied in production control technics specifically focused on commonly used parameter OEE (Overall Equipment Effectiveness). The indicators of extensive and intensive use of equipment are considered. Their appointment this is comparison in the same type of production within the industry and comparison of single-type and / or different types of equipment in terms of capacity. However, it is shown that there is no possibility of revealing the reasons for the machine’s operation: productive / unproductive, with disturbances. Therefore, in the article reveals the approaches to calculating the indicator characterizing the direct operation of the equipment. The Machine Load coefficient is approaching closely to the indicator of the efficiency of the use of equipment. Methods analysis is proceeded through the historically applied techniques such as “Stopwatch” and “Motion” studies. Was performed the analysis of the efficiency index of OEE equipment using the comparable indexes performance of equipment in the Russian practice. An important indicator of OEE contains three components. The meaning of each of them reflects historically applicable indicators. The value of the availability of equipment indicator is close to the value of the equipment extensibility index. The value of the indicator of the efficiency of work can be compared with the characteristic of the capacity of the equipment and the indicator of the quality level can meet the requirements for compliance with the manufacturing technology. Shown that the sum of the values of the coefficient of “Availability” of the equipment and the value of the “Factor of compaction of working hours” are one. As well as the total value of the indicator “level of quality” and the coefficient of marriage given in the result unit. The measurability of the indicators makes it possible to make a prediction about efficiency of the equipment.

  6. Engineer Equipment Mechanic.

    ERIC Educational Resources Information Center

    Marine Corps Inst., Washington, DC.

    Developed as part of the Marine Corps Institute (MCI) correspondence training program, this course on engineer equipment mechanics is designed to advance the professional competence of privates through sergeants as equipment mechanics, Military Occupation Specialty 1341, and is adaptable for nonmilitary instruction. Introductory materials include…

  7. Shipboard Electronic Equipments.

    ERIC Educational Resources Information Center

    Naval Personnel Program Support Activity, Washington, DC.

    Fundamentals of major electronic equipments on board ships are presented in this text prepared for naval officers in general. Basic radio principles are discussed in connection with various types of transmitters, receivers, antennas, couplers, transfer panels, remote-control units, frequency standard equipments, teletypewriters, and facsimile…

  8. Laboratory Equipment Criteria.

    ERIC Educational Resources Information Center

    State Univ. Construction Fund, Albany, NY.

    Requirements for planning, designing, constructing and installing laboratory furniture are given in conjunction with establishing facility criteria for housing laboratory equipment. Furniture and equipment described include--(1) center tables, (2) reagent racks, (3) laboratory benches and their mechanical fixtures, (4) sink and work counters, (5)…

  9. 14 CFR 121.345 - Radio equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Radio equipment. 121.345 Section 121.345..., FLAG, AND SUPPLEMENTAL OPERATIONS Instrument and Equipment Requirements § 121.345 Radio equipment. (a) No person may operate an airplane unless it is equipped with radio equipment required for the kind of...

  10. 1968 Listing of Swimming Pool Equipment.

    ERIC Educational Resources Information Center

    National Sanitation Foundation, Ann Arbor, MI. Testing Lab.

    An up-to-date listing of swimming pool equipment including--(1) companies authorized to display the National Sanitation Foundation seal of approval, (2) equipment listed as meeting NSF swimming pool equipment standards relating to diatomite type filters, (3) equipment listed as meeting NSF swimming pool equipment standard relating to sand type…

  11. Survey identifies trends in equipment acquisitions.

    PubMed

    Anderson, H J

    1990-09-20

    Automated laboratory equipment, medical imaging equipment, and patient monitors top the list of hospitals' priorities for equipment acquisition during the next year. This is according to an exclusive survey sponsored by the Linc Group, Inc., Chicago, and Hospitals magazine. The new survey also found that equipment acquisitions are most often financed with internal funds and gifts; that equipment purchasing budgets are on the rise; and that executives believe that most equipment makes money for their hospitals. Find out what your peers have to say about anticipated trends in equipment acquisition and financing during the next year.

  12. 10 CFR 431.405 - Exported equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Exported equipment. 431.405 Section 431.405 Energy... EQUIPMENT General Provisions § 431.405 Exported equipment. Under Sections 330 and 345 of the Act, this Part... for export from the United States (or such equipment was imported for export), unless such equipment...

  13. About Personal Protective Equipment (PPE)

    MedlinePlus

    ... Equipment for Infection Control Questions About Personal Protective Equipment (PPE) Share Tweet Linkedin Pin it More sharing ... Print Q1. How do manufacturers ensure personal protective equipment (PPE) is safe and effective? A1. To help ...

  14. Use of vascular access for haemodialysis in Europe: a report from the ERA-EDTA Registry.

    PubMed

    Noordzij, Marlies; Jager, Kitty J; van der Veer, Sabine N; Kramar, Reinhard; Collart, Frederic; Heaf, James G; Stojceva-Taneva, Olivera; Leivestad, Torbjørn; Buturovic-Ponikvar, Jadranka; Benítez Sánchez, Manuel; Moreso, Fransesc; Prütz, Karl G; Severn, Alison; Wanner, Christoph; Vanholder, Raymond; Ravani, Pietro

    2014-10-01

    Although arteriovenous fistulas (AVFs) are actively promoted, their use at the start of haemodialysis (HD) seems to be decreasing worldwide. In this paper, we describe recent trends in incidence and prevalence of vascular access types in Europe from 2005 to 2009 and their relationship with patient characteristics and survival. Ten European renal registries participating in the ERA-EDTA Registry provided data on incidence (n = 13,044) and/or prevalence (n = 75,715) of vascular access types. We used logistic regression to assess which factors influence the likelihood to be treated with an AVF rather than another type. The use of AVFs at the start of HD showed a significant decreasing trend from 42% in 2005 to 32% in 2009 (P < 0.0001), while the use of central venous catheters (CVCs) increased from 58 to 68% (P < 0.0001). A similar evolution pattern was observed for the prevalence; use of AVFs decreased from 66 to 62% and use of CVCs increased from 28 to 32%. There was a large international variation in the use of the different vascular access types. Female patients [adjusted odds ratio: 0.84, 95% confidence interval (CI): 0.78-0.90] and those ≥80 years (0.77, 95% CI: 0.67-0.90) were least likely to start HD with an AVF. In Europe, there is a decreasing trend in the use of AVFs and an increasing trend in the use of CVCs at the start and after the start of HD. We cannot explain all between-country variations we found, and more research is needed to clarify how healthcare around vascular access is organized in Europe. © The Author 2014. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  15. Use of complementary and alternative medicines in haemodialysis patients: a cross-sectional study from Palestine.

    PubMed

    Zyoud, Sa'ed H; Al-Jabi, Samah W; Sweileh, Waleed M; Tabeeb, Ghada H; Ayaseh, Nora A; Sawafta, Mayas N; Khdeir, Razan L; Mezyed, Diana O; Daraghmeh, Dala N; Awang, Rahmat

    2016-07-11

    Complementary and alternative medicine (CAM), and herbal therapies, are accepted worldwide, and have been important from medical, sociological and economic perspectives, among haemodialysis (HD) patients. The primary aim of this study was to evaluate the use of CAM among patients with end-stage renal disease (ESRD) who are undergoing HD. Face-to-face interviews of patients with ESRD undergoing HD from ten outpatient renal departments at a national level in Palestine were conducted from June 2014 to January 2015. A survey questionnaire, which included questions on socio-demographic and clinical characteristics, and on the CAM therapies that were used, was administered. Out of 267 patients interviewed, 172 patients used at least one type of CAM in the last month prior to the interview, and thus the utilisation rate was 64.4 %. Forty one (15.4 %) patients reported using one type of CAMs, while 18.7 % used two different CAMs and 30.3 % used more than two types of CAMs for their health status. Of the patients who used CAM, herbal therapies were used most often (43.5 %), followed by honey (35.6 %), diet (22.8 %), and exorcism in Islam (16.9 %). The herbal therapies mentioned most often were Nigella sativa L. (18.7 %), followed by Salvia officinalis L. (16.9 %), and Pimpinella anisum L. (10.5 %). In conclusion, the prevalence of CAM is relatively high in the selected population. Most patients used biological therapies such as herbal remedies, thus highlighting a greater need for patient education regarding CAM therapies and possible herb-drug interactions. Health care providers must be aware of the potential benefits and risks related to CAM use. There is a need for more clinical research pertaining to CAM to reach stronger evidence regarding potential benefits and risks related to CAM use.

  16. Lighting Equipment (Update to Listing)

    DOT National Transportation Integrated Search

    1996-05-06

    This listing contains equipment and manufacturers certified or deleted since publication of advisory circular 150/5345-53A, Airport lighting equipment certification program, on 5-15-95. The equipment and manufacturers will be added to or deleted from...

  17. Information technology equipment cooling method

    DOEpatents

    Schultz, Mark D.

    2015-10-20

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools air utilized by the rack of information technology equipment to cool the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat generated by the rack of information technology equipment.

  18. 40 CFR 160.61 - Equipment design.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Equipment design. 160.61 Section 160.61 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Equipment § 160.61 Equipment design. Equipment used in the generation...

  19. 21 CFR 226.30 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... CURRENT GOOD MANUFACTURING PRACTICE FOR TYPE A MEDICATED ARTICLES Construction and Maintenance of Facilities and Equipment § 226.30 Equipment. Equipment used for the manufacture, processing, packaging, bulk... maintained in a clean and orderly manner and shall be of suitable design, size, construction, and location to...

  20. 50 CFR 260.102 - Equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 9 2011-10-01 2011-10-01 false Equipment. 260.102 Section 260.102... Products for Human Consumption Requirements for Plants Operating Under Continuous Inspection on A Contract Basis 1 § 260.102 Equipment. All equipment used for receiving, washing, segregating, picking, processing...

  1. 40 CFR 792.61 - Equipment design.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Equipment design. 792.61 Section 792.61 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Equipment § 792.61 Equipment design. Equipment used in the...

  2. 47 CFR 18.203 - Equipment authorization.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Equipment authorization. 18.203 Section 18.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL EQUIPMENT Applications and Authorizations § 18.203 Equipment authorization. (a) Consumer ISM equipment, unless otherwise specified, must be authorized...

  3. 47 CFR 18.203 - Equipment authorization.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Equipment authorization. 18.203 Section 18.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL EQUIPMENT Applications and Authorizations § 18.203 Equipment authorization. (a) Consumer ISM equipment, unless otherwise specified, must be authorized...

  4. 47 CFR 18.203 - Equipment authorization.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Equipment authorization. 18.203 Section 18.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL EQUIPMENT Applications and Authorizations § 18.203 Equipment authorization. (a) Consumer ISM equipment, unless otherwise specified, must be authorized...

  5. 47 CFR 18.203 - Equipment authorization.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Equipment authorization. 18.203 Section 18.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL EQUIPMENT Applications and Authorizations § 18.203 Equipment authorization. (a) Consumer ISM equipment, unless otherwise specified, must be authorized...

  6. 47 CFR 18.203 - Equipment authorization.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Equipment authorization. 18.203 Section 18.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL EQUIPMENT Applications and Authorizations § 18.203 Equipment authorization. (a) Consumer ISM equipment, unless otherwise specified, must be authorized...

  7. 49 CFR 18.32 - Equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false Equipment. 18.32 Section 18.32 Transportation... Equipment. (a) Title. Subject to the obligations and conditions set forth in this section, title to equipment acquired under a grant or subgrant will vest upon acquisition in the grantee or subgrantee...

  8. Orbiter electrical equipment utilization baseline

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The baseline for utilization of Orbiter electrical equipment in both electrical and Environmental Control and Life Support System (ECLSS) thermal analyses is established. It is a composite catalog of Space Shuttle equipment, as defined in the Shuttle Operational Data Book. The major functions and expected usage of each component type are described. Functional descriptions are designed to provide a fundamental understanding of the Orbiter electrical equipment, to insure correlation of equipment usage within nominal analyses, and to aid analysts in the formulation of off-nominal, contingency analyses.

  9. Dairy Equipment Lubrication

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Lake To Lake Dairy Cooperative, Manitowoc, Wisconsin, operates four plants in Wisconsin for processing milk, butter and cheese products from its 1,300 member farms. The large co-op was able to realize substantial savings by using NASA information for improved efficiency in plant maintenance. Under contract to Marshall Space Flight Center, Midwest Research Institute compiled a handbook consolidating information about commercially available lubricants. The handbook details chemical and physical properties, applications, specifications, test procedures and test data for liquid and solid lubricants. Lake To Lake's plant engineer used the handbook to effect savings in maintenance labor and materials costs by reducing the number of lubricants used on certain equipment. Strict U.S. Department of Agriculture and Food and Drug Administration regulations preclude lubrication changes n production equipment, but the co-op's maintenance chief was able to eliminate seven types of lubricants for ancillary equipment, such as compressors and high pressure pumps. Handbook data enabled him to select comparable but les expensive lubricants in the materials consolidation process, and simplified lubrication schedules and procedures. The handbook is in continuing use as a reference source when a new item of equipment is purchased.

  10. Ranking of factors determining potassium mass balance in bicarbonate haemodialysis.

    PubMed

    Basile, Carlo; Libutti, Pasquale; Lisi, Piero; Teutonico, Annalisa; Vernaglione, Luigi; Casucci, Francesco; Lomonte, Carlo

    2015-03-01

    One of the most important pathogenetic factors involved in the onset of intradialysis arrhytmias is the alteration in electrolyte concentration, particularly potassium (K(+)). Two studies were performed: Study A was designed to investigate above all the isolated effect of the factor time t on intradialysis K(+) mass balance (K(+)MB): 11 stable prevalent Caucasian anuric patients underwent one standard (∼4 h) and one long-hour (∼8 h) bicarbonate haemodialysis (HD) session. The latter were pair-matched as far as the dialysate and blood volume processed (90 L) and volume of ultrafiltration are concerned. Study B was designed to identify and rank the other factors determining intradialysis K(+)MB: 63 stable prevalent Caucasian anuric patients underwent one 4-h standard bicarbonate HD session. Dialysate K(+) concentration was 2.0 mmol/L in both studies. Blood samples were obtained from the inlet blood tubing immediately before the onset of dialysis and at t60, t120, t180 min and at end of the 4- and 8-h sessions for the measurement of plasma K(+), blood bicarbonates and blood pH. Additional blood samples were obtained at t360 min for the 8 h sessions. Direct dialysate quantification was utilized for K(+)MBs. Direct potentiometry with an ion-selective electrode was used for K(+) measurements. Study A: mean K(+)MBs were significantly higher in the 8-h sessions (4 h: -88.4 ± 23.2 SD mmol versus 8 h: -101.9 ± 32.2 mmol; P = 0.02). Bivariate linear regression analyses showed that only mean plasma K(+), area under the curve (AUC) of the hourly inlet dialyser diffusion concentration gradient of K(+) (hcgAUCK(+)) and AUC of blood bicarbonates and mean blood bicarbonates were significantly related to K(+)MB in both 4- and 8-h sessions. A multiple linear regression output with K(+)MB as dependent variable showed that only mean plasma K(+), hcgAUCK(+) and duration of HD sessions per se remained statistically significant. Study B: mean K(+)MBs were -86.7 ± 22.6 mmol

  11. 47 CFR 74.852 - Equipment changes.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Equipment changes. 74.852 Section 74.852... Equipment changes. (a) The licensee of a low power auxiliary station may make any changes in the equipment that are deemed desirable or necessary, including replacement with certificated equipment, without...

  12. 33 CFR 142.48 - Eyewash equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CONTINENTAL SHELF ACTIVITIES WORKPLACE SAFETY AND HEALTH Personal Protective Equipment § 142.48 Eyewash equipment. Portable or fixed eyewash equipment providing emergency relief must be immediately available near... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Eyewash equipment. 142.48 Section...

  13. 33 CFR 142.48 - Eyewash equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CONTINENTAL SHELF ACTIVITIES WORKPLACE SAFETY AND HEALTH Personal Protective Equipment § 142.48 Eyewash equipment. Portable or fixed eyewash equipment providing emergency relief must be immediately available near... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Eyewash equipment. 142.48 Section...

  14. Extraction of 223Radium by haemodialysis after treatment of metastatic castration-resistant prostate cancer.

    PubMed

    Großer, Oliver Stephan; Wissel, Heiko; Wallbaum, Thekla; Genseke, Philipp; Kupitz, Dennis; Ricke, Jens; Ruf, Juri; Amthauer, Holger

    2017-06-13

    223 Radium-dichloride ( 223 Ra) administration is an upcoming therapeutic option in patients with castration-resistant metastatic prostate cancer (mCRPC), whose renal and faecal excretion of 223 Ra has been primarily estimated from data of a phase-I clinical trial in patients with normal renal function. In the rare case of concomitant renal insufficiency requiring haemodialysis (HD), an estimation of the contamination of dialysate would be beneficial. The excretion of 223 Ra and its concentration in the dialysate in a patient with mCRPC and end-stage renal disease was examined for six consecutive treatment cycles. Dialysate samples were measured using a commercial system with NaI-scintillation detector. HD showed a residual activity level in the remaining dialysate. The excreted activity was a median of 46.1 kBq (range = 42.0- 83.4 kBq) and 11.2 kBq (range = 8.4- 19.9 kBq) for the first (24 h post injection p.i.) and second HD (96 h p.i.), respectively. The activity concentration decreased significantly from a median of 4.18 kBq/l (range = 2.98-5.14 kBq/l) to 0.85 kBq/l (range = 0.69- 1.31 kBq/l, p < 0.0001). For all consecutive time points, the activity concentration further decreased significantly (p < 0.0001). The activity concentration of dialysate from HD performed 125.4 h p.i. [95 % confidence interval = 120.5-130.4 h p.i.] reached the threshold for unrestricted waste disposal. The observed extraction of 223 Ra by HD exceeded the data determined from the phase-I study. The activity concentration in the dialysate observed for the first HD's p.i. was above the threshold for unrestricted disposal of radioactive waste in Germany. Therefore, the specific requirement for waste handling has to be followed to fulfil the radiation protection regulations.

  15. 45 CFR 1157.32 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Equipment. 1157.32 Section 1157.32 Public Welfare... AND LOCAL GOVERNMENTS Post-Award Requirements Changes, Property, and Subawards § 1157.32 Equipment. (a) Title. Subject to the obligations and conditions set forth in this section, title to equipment acquired...

  16. 45 CFR 1174.32 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Equipment. 1174.32 Section 1174.32 Public Welfare... STATE AND LOCAL GOVERNMENTS Post-Award Requirements Changes, Property, and Subawards § 1174.32 Equipment. (a) Title. Subject to the obligations and conditions set forth in this section, title to equipment...

  17. 45 CFR 602.32 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Equipment. 602.32 Section 602.32 Public Welfare....32 Equipment. (a) Title. Subject to the obligations and conditions set forth in this section, title to equipment acquired under a grant or subgrant will vest upon acquisition in the grantee or...

  18. 45 CFR 1183.32 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Equipment. 1183.32 Section 1183.32 Public Welfare... Equipment. (a) Title. Subject to the obligations and conditions set forth in this section, title to equipment acquired under a grant or subgrant will vest upon acquisition in the grantee or subgrantee...

  19. 44 CFR 13.32 - Equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 44 Emergency Management and Assistance 1 2011-10-01 2011-10-01 false Equipment. 13.32 Section 13... LOCAL GOVERNMENTS Post-Award Requirements Changes, Property, and Subawards § 13.32 Equipment. (a) Title. Subject to the obligations and conditions set forth in this section, title to equipment acquired under a...

  20. 43 CFR 12.72 - Equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Equipment. 12.72 Section 12.72 Public... to State and Local Governments Changes, Property, and Subawards § 12.72 Equipment. (a) Title. Subject to the obligations and conditions set forth in this section, title to equipment acquired under a...

  1. 44 CFR 13.32 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Equipment. 13.32 Section 13... LOCAL GOVERNMENTS Post-Award Requirements Changes, Property, and Subawards § 13.32 Equipment. (a) Title. Subject to the obligations and conditions set forth in this section, title to equipment acquired under a...

  2. 49 CFR 195.430 - Firefighting equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Firefighting equipment. 195.430 Section 195.430... PIPELINE Operation and Maintenance § 195.430 Firefighting equipment. Each operator shall maintain adequate firefighting equipment at each pump station and breakout tank area. The equipment must be— (a) In proper...

  3. 14 CFR 25.1431 - Electronic equipment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electronic equipment. 25.1431 Section 25... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 25.1431 Electronic equipment. (a) In showing compliance with § 25.1309 (a) and (b) with respect to radio and electronic...

  4. 14 CFR 25.1431 - Electronic equipment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electronic equipment. 25.1431 Section 25... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 25.1431 Electronic equipment. (a) In showing compliance with § 25.1309 (a) and (b) with respect to radio and electronic...

  5. 14 CFR 25.1431 - Electronic equipment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electronic equipment. 25.1431 Section 25... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 25.1431 Electronic equipment. (a) In showing compliance with § 25.1309 (a) and (b) with respect to radio and electronic...

  6. 14 CFR 25.1431 - Electronic equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electronic equipment. 25.1431 Section 25... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 25.1431 Electronic equipment. (a) In showing compliance with § 25.1309 (a) and (b) with respect to radio and electronic...

  7. 40 CFR 792.61 - Equipment design.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 32 2011-07-01 2011-07-01 false Equipment design. 792.61 Section 792... (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Equipment § 792.61 Equipment design. Equipment used in the... of appropriate design and adequate capacity to function according to the protocol and shall be...

  8. 40 CFR 160.61 - Equipment design.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Equipment design. 160.61 Section 160... LABORATORY PRACTICE STANDARDS Equipment § 160.61 Equipment design. Equipment used in the generation... appropriate design and adequate capacity to function according to the protocol and shall be suitably located...

  9. Management methodology for pressure equipment

    NASA Astrophysics Data System (ADS)

    Bletchly, P. J.

    Pressure equipment constitutes a significant investment in capital and a major proportion of potential high-risk plant in many operations and this is particularly so in an alumina refinery. In many jurisdictions pressure equipment is also subject to statutory regulation that imposes obligations on Owners of the equipment with respect to workplace safety. Most modern technical standards and industry codes of practice employ a risk-based approach to support better decision making with respect to pressure equipment. For a management system to be effective it must demonstrate that risk is being managed within acceptable limits.

  10. 14 CFR 23.1431 - Electronic equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electronic equipment. 23.1431 Section 23... Equipment § 23.1431 Electronic equipment. (a) In showing compliance with § 23.1309(b)(1) and (2) with respect to radio and electronic equipment and their installations, critical environmental conditions must...

  11. 14 CFR 23.1431 - Electronic equipment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electronic equipment. 23.1431 Section 23... Equipment § 23.1431 Electronic equipment. (a) In showing compliance with § 23.1309(a), (b), and (c) with respect to radio and electronic equipment and their installations, critical environmental conditions must...

  12. 14 CFR 23.1431 - Electronic equipment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electronic equipment. 23.1431 Section 23... Equipment § 23.1431 Electronic equipment. (a) In showing compliance with § 23.1309(a), (b), and (c) with respect to radio and electronic equipment and their installations, critical environmental conditions must...

  13. 21 CFR 58.61 - Equipment design.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Equipment design. 58.61 Section 58.61 Food and... PRACTICE FOR NONCLINICAL LABORATORY STUDIES Equipment § 58.61 Equipment design. Equipment used in the... of appropriate design and adequate capacity to function according to the protocol and shall be...

  14. 21 CFR 58.61 - Equipment design.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Equipment design. 58.61 Section 58.61 Food and... PRACTICE FOR NONCLINICAL LABORATORY STUDIES Equipment § 58.61 Equipment design. Equipment used in the... of appropriate design and adequate capacity to function according to the protocol and shall be...

  15. 45 CFR 92.32 - Equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 1 2011-10-01 2011-10-01 false Equipment. 92.32 Section 92.32 Public Welfare..., Property, and Subawards § 92.32 Equipment. (a) Title. Subject to the obligations and conditions set forth in this section, title to equipment acquired under a grant or subgrant will vest upon acquisition in...

  16. 34 CFR 74.34 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... following standards: (1) For equipment with a current per unit fair market value of $5000 or more, the... the cost of the original project or program to the current fair market value of the equipment. (2) If... the current fair market value of the equipment, plus any reasonable shipping or interim storage costs...

  17. 2 CFR 215.34 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... disposal and sales price or the method used to determine current fair market value where a recipient... accordance with the following standards. For equipment with a current per unit fair market value of $5000 or... fair market value of the equipment. If the recipient has no need for the equipment, the recipient shall...

  18. 38 CFR 49.34 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... disposal and sales price or the method used to determine current fair market value where a recipient... accordance with the following standards. For equipment with a current per unit fair market value of $5000 or... fair market value of the equipment. If the recipient has no need for the equipment, the recipient shall...

  19. 7 CFR 550.38 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... or the method used to determine current fair market value where a Cooperator compensates the REE... the current fair market value of the equipment. If the Cooperator has no need for the equipment, the... cost of the original project or program to the current fair market value of the equipment, plus any...

  20. Development of Turbulence-Measuring Equipment

    NASA Technical Reports Server (NTRS)

    Kovasznay, Leslie S G

    1954-01-01

    Hot wire turbulence-measuring equipment has been developed to meet the more stringent requirements involved in the measurement of fluctuations in flow parameters at supersonic velocities. The higher mean speed necessitates the resolution of higher frequency components than at low speed, and the relatively low turbulence level present at supersonic speed makes necessary an improved noise level for the equipment. The equipment covers the frequency range from 2 to about 70,000 cycles per second. Constant-current operation is employed. Compensation for hot-wire lag is adjusted manually using square-wave testing to indicate proper setting. These and other features make the equipment adaptable to all-purpose turbulence work with improved utility and accuracy over that of older types of equipment. Sample measurements are given to demonstrate the performance.

  1. 14 CFR 23.1561 - Safety equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Safety equipment. 23.1561 Section 23.1561... Markings and Placards § 23.1561 Safety equipment. (a) Safety equipment must be plainly marked as to method of operation. (b) Stowage provisions for required safety equipment must be marked for the benefit of...

  2. 14 CFR 23.1561 - Safety equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Safety equipment. 23.1561 Section 23.1561... Markings and Placards § 23.1561 Safety equipment. (a) Safety equipment must be plainly marked as to method of operation. (b) Stowage provisions for required safety equipment must be marked for the benefit of...

  3. Equipment for Microgravity Research

    NASA Technical Reports Server (NTRS)

    Fountain, J. A.

    1986-01-01

    Illustrated catalog describes equipment and facilities available for experiments under low-gravity conditions. Catalog encourages scientific and commercial organizations to investigate benefits of conducting research and manufacturing activities in microgravity environment. Catalog covers equipment ranging from containers to spacecraft.

  4. 43 CFR 12.934 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... disposal and sales price or the method used to determine current fair market value where a recipient... accordance with the following standards. For equipment with a current per unit fair market value of $5,000 or... fair market value of the equipment. If the recipient has no need for the equipment, the recipient shall...

  5. 32 CFR 32.34 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... current fair market value where a recipient compensates the DoD Component that made the award for its... following standards. (1) For equipment with a current per unit fair market value of $5,000 or more, the... current fair market value of the equipment. (2) If the recipient has no need for the equipment, the...

  6. 14 CFR 23.1431 - Electronic equipment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electronic equipment. 23.1431 Section 23... Equipment § 23.1431 Electronic equipment. Link to an amendment published at 76 FR 75761, December 2, 2011. (a) In showing compliance with § 23.1309(b)(1) and (2) with respect to radio and electronic equipment...

  7. 10 CFR 600.134 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... the following standards. Equipment with a current per-unit fair market value of less than $5000 may be... with a current per unit fair market value of $5000 or more, the recipient may retain the equipment for... the cost of the original project or program to the current fair market value of the equipment. If the...

  8. 14 CFR 29.1431 - Electronic equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... equipment. (a) Radio communication and navigation equipment installations must be free from hazards in... environmental conditions. (b) Radio communication and navigation equipment, controls, and wiring must be...

  9. The financial impact of increasing home-based high dose haemodialysis and peritoneal dialysis.

    PubMed

    Liu, Frank Xiaoqing; Treharne, Catrin; Culleton, Bruce; Crowe, Lydia; Arici, Murat

    2014-10-02

    Evidence suggests that high dose haemodialysis (HD) may be associated with better health outcomes and even cost savings (if conducted at home) versus conventional in-centre HD (ICHD). Home-based regimens such as peritoneal dialysis (PD) are also associated with significant cost reductions and are more convenient for patients. However, the financial impact of increasing the use of high dose HD at home with an increased tariff is uncertain. A budget impact analysis was performed to investigate the financial impact of increasing the proportion of patients receiving home-based dialysis modalities from the perspective of the England National Health Service (NHS) payer. A Markov model was constructed to investigate the 5 year budget impact of increasing the proportion of dialysis patients receiving home-based dialysis, including both high dose HD at home and PD, under the current reimbursement tariff and a hypothetically increased tariff for home HD (£575/week). Five scenarios were compared with the current England dialysis modality distribution (prevalent patients, 14.1% PD, 82.0% ICHD, 3.9% conventional home HD; incident patients, 22.9% PD, 77.1% ICHD) with all increases coming from the ICHD population. Under the current tariff of £456/week, increasing the proportion of dialysis patients receiving high dose HD at home resulted in a saving of £19.6 million. Conducting high dose HD at home under a hypothetical tariff of £575/week was associated with a budget increase (£19.9 million). The costs of high dose HD at home were totally offset by increasing the usage of PD to 20-25%, generating savings of £40.0 million - £94.5 million over 5 years under the increased tariff. Conversely, having all patients treated in-centre resulted in a £172.6 million increase in dialysis costs over 5 years. This analysis shows that performing high dose HD at home could allow the UK healthcare system to capture the clinical and humanistic benefits associated with this therapy while

  10. Equipment Readiness Code Rule System (ERCRULES)

    DTIC Science & Technology

    1988-06-01

    Food inspection...CAA-SR-88-14 branch = ahs and equipment = ’Water quality set"’ or equipment = ’ Food inspection set’ then erc-assigned = [unitcriticalfacility,’ERC A...8217,𔃿.5.15𔃻. if not branch = qms and not branch = ahs and equipment = ’Water quality set’’ or equipment = ’ Food inspection set’ then

  11. Trends in the treatment of chronic kidney disease-associated anaemia in a cohort of haemodialysis patients: the Irish experience.

    PubMed

    Gardiner, Roisin; Roshan, Davood; Brennan, Ann; Connolly, Denise; Murray, Susan; Reddan, Donal

    2018-04-27

    Anaemia among haemodialysis patients is treated with iron and erythropoietin-stimulating agents (ESAs). ESAs reduce requirements for blood transfusions but are also expensive and overzealous use may be associated with adverse outcomes. Recent international trends have been characterised by reduced ESA doses and a greater reliance on intravenous (IV) iron. We determined trends in prescribing patterns of ESAs and IV iron for the treatment of anaemia in two representative Irish dialysis centres and correlated with current guidelines and international trends. Patient data was accessed from the Kidney Disease Clinical Patient Management System (KDCPMS) for the period 2012 to 2014. We generated reports on ESA and iron doses, lab data (haemoglobin (Hb), transferrin saturation (TSAT) and ferritin) and patient population characteristics. We mapped the trends in ESA, iron dosing and lab parameters achieved. A linear mixed model determined the significance of these trends over time. ESA dosing became lower in the second, third and fourth quarters of 2014. Dosing of iron increased throughout but a large increase was seen in the third and fourth quarters of 2014. Ferritin levels decreased and TSAT and haemoglobin levels increased. Changes in iron dosing were significant with p value of < 0.05. Our findings are consistent with recent global trends toward increasing iron use. Such trends may have economic implications given the high cost of ESAs and the relative affordability of iron. In addition, the potential harm of excessive iron dosing may need to be considered.

  12. 46 CFR 154.1430 - Equipment locker.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Equipment locker. 154.1430 Section 154.1430 Shipping... Equipment § 154.1430 Equipment locker. One of each item of equipment under §§ 154.1400 and 154.1420 must be stowed in a marked locker: (a) On the open deck in or adjacent to the cargo area; or (b) In the...

  13. 46 CFR 154.1430 - Equipment locker.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Equipment locker. 154.1430 Section 154.1430 Shipping... Equipment § 154.1430 Equipment locker. One of each item of equipment under §§ 154.1400 and 154.1420 must be stowed in a marked locker: (a) On the open deck in or adjacent to the cargo area; or (b) In the...

  14. 46 CFR 154.1430 - Equipment locker.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Equipment locker. 154.1430 Section 154.1430 Shipping... Equipment § 154.1430 Equipment locker. One of each item of equipment under §§ 154.1400 and 154.1420 must be stowed in a marked locker: (a) On the open deck in or adjacent to the cargo area; or (b) In the...

  15. 46 CFR 154.1430 - Equipment locker.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Equipment locker. 154.1430 Section 154.1430 Shipping... Equipment § 154.1430 Equipment locker. One of each item of equipment under §§ 154.1400 and 154.1420 must be stowed in a marked locker: (a) On the open deck in or adjacent to the cargo area; or (b) In the...

  16. 46 CFR 154.1430 - Equipment locker.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Equipment locker. 154.1430 Section 154.1430 Shipping... Equipment § 154.1430 Equipment locker. One of each item of equipment under §§ 154.1400 and 154.1420 must be stowed in a marked locker: (a) On the open deck in or adjacent to the cargo area; or (b) In the...

  17. 14 CFR 25.1439 - Protective breathing equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... must include— (i) Masks covering the eyes, nose and mouth, or (ii) Masks covering the nose and mouth, plus accessory equipment to cover the eyes. (3) Equipment, including portable equipment, must allow... also enable the flightcrew to use radio equipment. (4) The part of the equipment protecting the eyes...

  18. Equipment Efficiency for Healthy School Meals. [Videotape].

    ERIC Educational Resources Information Center

    National Food Service Management Inst., University, MS.

    A satellite seminar on large-scale food production equipment discusses ways child nutrition personnel can maximize use of existing equipment, considers research related to use of existing equipment, explains plan reviews for equipment selection and purchase, and explores new equipment options. Examples illustrate use of planning or modernizing…

  19. 46 CFR 153.484 - Prewash equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Design and Equipment for Pollution Control § 153.484 Prewash equipment. Unless the ship operator shows that the prewash...

  20. 46 CFR 153.484 - Prewash equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Design and Equipment for Pollution Control § 153.484 Prewash equipment. Unless the ship operator shows that the prewash...

  1. 46 CFR 153.484 - Prewash equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Design and Equipment for Pollution Control § 153.484 Prewash equipment. Unless the ship operator shows that the prewash...

  2. 46 CFR 153.484 - Prewash equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Design and Equipment for Pollution Control § 153.484 Prewash equipment. Unless the ship operator shows that the prewash...

  3. 46 CFR 153.484 - Prewash equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Design and Equipment for Pollution Control § 153.484 Prewash equipment. Unless the ship operator shows that the prewash...

  4. [Surgical learning curve for creation of vascular accesses for haemodialysis: value of medico-radio-surgical collaboration].

    PubMed

    Van Glabeke, Emmanuel; Belenfant, Xavier; Barrou, Benoît; Adhemar, Jean-Pierre; Laedrich, Joëlle; Mavel, Marie-Christine; Challier, Emmanuel

    2005-04-01

    Creation of a vascular access (VA) for haemodialysis is a surgical procedure which comprises a failure rate related to the quality of the vessels and the operator's experience. The authors report the first 2 years of a young urologist's experience with this procedure in a local hospital in collaboration with the nephrology team. Patients undergoing creation of VA were divided into 2 chronological groups. The patient's age and gender, the cause of renal failure, the presence of diabetes, clinical examination of the upper limb, preoperative assessment of upper limb vessels, the type of anaesthesia, the operating time and the start of dialysis after the operation, as well as the functional results of the VA at 6 months were studied. Results concerning the patients of the first period were discussed by the operator and the nephrology team. During the first 9 months, 28 patients were operated, corresponding to 36 operations including 32 direct fistulas. Over the following 15 months, 61 patients were operated, with the creation of 63 VAs, including 55 direct fistulas. The failure rate (thrombosis or non-functioning VA) decreased from 32.1% to 11.1% (p=0.07), while the 2 groups were globally comparable. Evaluation of a new surgical procedure shows a number of failures, as for all learning curves. However, it helps to improve the results. Collaboration with nephrologists must comprise a discussion allowing the acceptance of certain failures, as they reflect compliance with a strategy of preservation of the vascular capital and a rational attempt to avoid a non-essential proximal access or bypass graft. The support of a motivated radiology team (preoperative assessment and management of complications) and the assistance of a more experienced operator are essential.

  5. Diagnosis and prevalence of protein-energy wasting and its association with mortality in Japanese haemodialysis patients.

    PubMed

    Kanazawa, Yoshie; Nakao, Toshiyuki; Murai, Seizo; Okada, Tomonari; Matsumoto, Hiroshi

    2017-07-01

    The International Society of Renal Nutrition and Metabolism (ISRNM) has proposed the diagnostic criteria for protein-energy wasting (PEW). We studied Japanese haemodialysis (HD) patients to verify the diagnostic method, especially with respect to the body mass index (BMI) criterion, as well as the prevalence of PEW and its association with mortality. Japanese patients receiving maintenance HD at three outpatient clinics in Tokyo (n = 210) were enrolled, and prospectively followed-up for 3 years. PEW was diagnosed at baseline, according to the four categories (serum chemistry, body mass, muscle mass and dietary intake) recommended by the ISRNM. For the category of body mass, we select a body mass index (BMI) and set up three thresholds, <18.5, <20.0 and <23.0 kg/m 2 , as the diagnostic criterion. The patients who satisfied at least three out of the four categories were diagnosed as PEW. Protein-energy wasting, when the threshold of a BMI among the diagnostic criteria was defined as <18.5 kg/m 2 , was recognized as an independent risk factor for mortality. However, PEW was not recognized as a risk factor when the BMI diagnostic criterion was set at <20.0 or <23.0 kg/m 2 . Overall, 14.8% of the patients had PEW. The survival rate of PEW patients was significantly lower than that of non-PEW patients (log rank, P < 0.001). The diagnosis algorithm of PEW proposed by an expert panel of the ISRNM strongly associates with mortality. However, given differences in body size in Japan, we suggest to revise the BMI criterion from <23.0 kg/m 2 to <18.5 kg/m 2 . © 2016 Asian Pacific Society of Nephrology.

  6. Prioritizing equipment for replacement.

    PubMed

    Capuano, Mike

    2010-01-01

    It is suggested that clinical engineers take the lead in formulating evaluation processes to recommend equipment replacement. Their skill, knowledge, and experience, combined with access to equipment databases, make them a logical choice. Based on ideas from Fennigkoh's scheme, elements such as age, vendor support, accumulated maintenance cost, and function/risk were used.6 Other more subjective criteria such as cost benefits and efficacy of newer technology were not used. The element of downtime was also omitted due to the data element not being available. The resulting Periop Master Equipment List and its rationale was presented to the Perioperative Services Program Council. They deemed the criteria to be robust and provided overwhelming acceptance of the list. It was quickly put to use to estimate required capital funding, justify items already thought to need replacement, and identify high-priority ranked items for replacement. Incorporating prioritization criteria into an existing equipment database would be ideal. Some commercially available systems do have the basic elements of this. Maintaining replacement data can be labor-intensive regardless of the method used. There is usually little time to perform the tasks necessary for prioritizing equipment. However, where appropriate, a clinical engineering department might be able to conduct such an exercise as shown in the following case study.

  7. 46 CFR 109.347 - Pilot boarding equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Pilot boarding equipment. 109.347 Section 109.347... OPERATIONS Operation and Stowage of Safety Equipment § 109.347 Pilot boarding equipment. (a) The master or person in charge shall ensure that pilot boarding equipment is maintained as follows: (1) The equipment...

  8. 46 CFR 109.347 - Pilot boarding equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Pilot boarding equipment. 109.347 Section 109.347... OPERATIONS Operation and Stowage of Safety Equipment § 109.347 Pilot boarding equipment. (a) The master or person in charge shall ensure that pilot boarding equipment is maintained as follows: (1) The equipment...

  9. Dry skin (xerosis) in patients undergoing maintenance haemodialysis: the role of decreased sweating of the eccrine sweat gland.

    PubMed

    Park, T H; Park, C H; Ha, S K; Lee, S H; Song, K S; Lee, H Y; Han, D S

    1995-12-01

    The aetiology and the pathophysiological mechanisms underlying the development of dry skin in uraemia are still unclear, but the hydration status of stratum corneum clearly influences the appearance of skin. The xerotic skin texture is often referred to as 'dry skin' and has been suggested as a cause of uraemic pruritus. To understand the aetiology of dry skin in uraemia we measured the status of skin surface hydration of uraemic patients with the corneometer and skin surface hydrometer, the functional capacity and the urea concentration of stratum corneum and the response of eccrine sweat gland to sudorific agent (0.05% pilocarpine HCL) in 18 age-matched haemodialysis patients and 10 healthy volunteers. We also performed the water sorption-desorption test to uraemic and control subjects after application of urea in various concentrations. Uraemic patient's skin showed decreased water content compared to control subjects. However, we found no correlation between dry skin and pruritus. Although the urea concentration of the horny layer in uraemic patients was elevated compared to control subjects (28.2 microgram/cm2 vs 5.04 micrograms/cm2, P < 0.05), its moisturizing effect to relieve pruritus is questionable because its artificial application revealed no improvement of the functional capacity of horny layer in concentration 5 times higher than the physiological concentration. Uraemic patients showed decreased sweating response to sudorific agent. In conclusion, the functional abnormalities of eccrine sweat glands may be account for dry skin in uraemic patients at least in part, but there is no correlation between xerosis and pruritus.

  10. Suggested techniques, equipment, and standards for the testing of hand insecticide-spraying equipment

    PubMed Central

    Hall, Lawrence B.

    1955-01-01

    The new demands placed upon application equipment by the introduction of modern insecticides have revealed the deficiencies of this equipment when required for continuous use on a large scale. If adequate equipment is to be produced, specifications must be based not only on basic materials tests but also on “use” tests, in which the conditions of field use are simulated. The author outlines suggested techniques to be followed and standards to be adopted in testing the performance of compression sprayers and allied equipment, with reference to the following features: compression-sprayer tank fatigue; tank impact; pump resistance to bursting; pump resistance to collapse; pump friction; cut-off valve durability; constant-pressure valves; cut-off valve actuation; hose flexure; hose tension and bursting-pressure; hose friction; gaskets, valve faces, and similar non-metallic parts; nozzle-orifice erosion; and nozzle pattern. ImagesFIG. 1FIG. 14FIG. 20 PMID:14364189

  11. Serum omentin-1 levels as a possible risk factor of mortality in patients with diabetes on haemodialysis.

    PubMed

    Kocijancic, Marija; Vujicic, Bozidar; Racki, Sanjin; Cubranic, Zlatko; Zaputovic, Luka; Dvornik, Stefica

    2015-10-01

    The main cause of mortality in haemodialysis (HD) patients is cardiovascular disease. Serum omentin-1 level was found to be associated with cardio-metabolic disorders. The aim of this study was to examine the role of omentin-1 as a predictor of mortality in a group of diabetes positive HD patients. A total of 120 prevalent HD patients were included in the study from December 2012 to May 2014. Patients were divided into two groups according to the presence or absence of diabetes. Venous blood samples were taken at months 0 and 18 following an overnight fast (prior to a midweek HD session). Serum omentin-1 level was assessed by enzyme-linked immunosorbent assay. A total of 84 HD patients were analysed at the end of an 18-month follow-up. Omentin-1 levels of HD patients with diabetes were found to be lower than of HD patients without diabetes (9.1±5.8 ng/mL vs. 11.4±4.1 ng/mL, respectively; P=0.015) at the end of follow-up. Omentin-1 levels of survived patients with diabetes were found to be higher than of nonsurvived patients with diabetes (16.5±10.1 ng/mL vs. 12.9±5.3 ng/mL, respectively; P=0.045). During follow-up, 36 patients (30%) died, of whom 25 had diabetes (34%). Serum omentin-1 levels were significantly lower in HD patients with diabetes. A decrease in omentin-1 levels could be an independent mortality risk factor in this patient group. Further investigation in a greater number of patients is needed. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Determinants of bone mineral density in patients on haemodialysis or peritoneal dialysis--a cross-sectional, longitudinal study.

    PubMed

    Nybo, Mads; Jespersen, Bente; Aarup, Michael; Ejersted, Charlotte; Hermann, Anne Pernille; Brixen, Kim

    2013-01-01

    The aim of the study was to identify biomarkers of alteration in bone mineral density (BMD) in patients on haemodialysis (HD) and peritoneal dialysis (PD). In a cross-sectional, longitudinal study dual-energy X-ray absorptiometry scans were performed in 146 HD-patients and 28 PD-patients. Follow-up after 14 months (mean) was conducted in 73 patients. As potential biomarkers we investigated parathyroid hormone (PTH), 25-hydroxy vitamin-D, ionised calcium, albumin, phosphate, and total alkaline phosphatases (t-ALP). Both groups of dialysis patients had lower BMD in the femoral neck (BMD(neck)) (P < 0.001) and forearm (BMD(forearm)) (P < 0.001) compared to healthy controls, but comparable BMD in the lumbar spine (BMD(spine)). BMD did not differ between dialysis types, but patients ever-treated with glucocorticoids had significantly lower BMD, while patients with polycystic kidney disease had higher BMD. BMD correlated with body weight, actual age, age at initiation of dialysis, duration of dialysis and levels of PTH and t-ALP. However, t-ALP only remained associated with low BMD(spine) after adjusting for other factors (P = 0.001). In the follow-up study all patients had decreased BMD in all three locations, but only for the lumbar spine there was a significant association between BMD and the bone markers t-ALP (P = 0.009) and PTH (P = 0.013). Both HD and PD patients have low BMD, and increased concentrations of t-ALP is associated BMD(spine) after adjustment, while PTH and t-ALP is associated with decrease in BMD(spine) over time. This substantiates the use of these biomarkers in both types of dialysis patients.

  13. Information technology equipment cooling system

    DOEpatents

    Schultz, Mark D.

    2014-06-10

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools warm air generated by the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat from the rack of information technology equipment.

  14. 2 CFR 200.89 - Special purpose equipment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... equipment. Special purpose equipment means equipment which is used only for research, medical, scientific... machines, surgical instruments, and spectrometers. See also §§ 200.33 Equipment and 200.48 General purpose...

  15. Equipment Operator 1 & C.

    ERIC Educational Resources Information Center

    Naval Education and Training Program Development Center, Pensacola, FL.

    The Rate Training Manual and Nonresident Career Course (RTM/NRCC) form a self-study package to assist Navy Equipment Operators First and Chief in fulfilling the requirements of their rating. (Navy Equipment Operators First and Chief direct and coordinate efforts of individuals and crews in construction, earthmoving, roadbuilding, quarrying, and…

  16. Find Funds for Wellness Assessment Equipment.

    ERIC Educational Resources Information Center

    Buck, Marilyn M.; Kirkpatrick, Beth

    1995-01-01

    Many physical education teachers have difficulty finding ways to purchase wellness assessment equipment. The article provides strategies to help them find the money for needed equipment, highlighting the physical education budget, the computer equipment budget, grants, local businesses, statewide organizations, universities, and national…

  17. 29 CFR 1915.158 - Lifesaving equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Personal Protective Equipment (PPE) § 1915.158 Lifesaving equipment. (a) Personal flotation devices. (1) PFDs (life preservers, life... Equipment Specifications. (2) Prior to each use, personal floatation devices shall be inspected for dry rot...

  18. 29 CFR 1915.158 - Lifesaving equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Personal Protective Equipment (PPE) § 1915.158 Lifesaving equipment. (a) Personal flotation devices. (1) PFDs (life preservers, life... Equipment Specifications. (2) Prior to each use, personal floatation devices shall be inspected for dry rot...

  19. Equipment Management Manual

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The NASA Equipment Management Manual (NHB 4200.1) is issued pursuant to Section 203(c)(1) of the National Aeronautics and Space Act of 1958, as amended (42 USC 2473), and sets forth policy, uniform performance standards, and procedural guidance to NASA personnel for the acquisition, management, and use of NASA-owned equipment. This revision is effective upon receipt. This is a controlled manual, issued in loose-leaf form, and revised through page changes. Additional copies for internal use may be obtained through normal distribution.

  20. 47 CFR 80.1103 - Equipment authorization.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Equipment authorization. 80.1103 Section 80.1103 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... for Ship Stations § 80.1103 Equipment authorization. (a) All equipment specified in § 80.1101 must be...

  1. 33 CFR 175.135 - Existing equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Existing equipment. 175.135 Section 175.135 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) BOATING SAFETY EQUIPMENT REQUIREMENTS Visual Distress Signals § 175.135 Existing equipment. Launchers...

  2. 33 CFR 175.135 - Existing equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Existing equipment. 175.135 Section 175.135 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) BOATING SAFETY EQUIPMENT REQUIREMENTS Visual Distress Signals § 175.135 Existing equipment. Launchers...

  3. 33 CFR 175.135 - Existing equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Existing equipment. 175.135 Section 175.135 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) BOATING SAFETY EQUIPMENT REQUIREMENTS Visual Distress Signals § 175.135 Existing equipment. Launchers...

  4. 33 CFR 175.135 - Existing equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Existing equipment. 175.135 Section 175.135 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) BOATING SAFETY EQUIPMENT REQUIREMENTS Visual Distress Signals § 175.135 Existing equipment. Launchers...

  5. 33 CFR 175.135 - Existing equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Existing equipment. 175.135 Section 175.135 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) BOATING SAFETY EQUIPMENT REQUIREMENTS Visual Distress Signals § 175.135 Existing equipment. Launchers...

  6. 47 CFR 32.2232 - Circuit equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... subaccount 2232.1 Electronic shall include the original cost of electronic circuit equipment. (c) This... 47 Telecommunication 2 2011-10-01 2011-10-01 false Circuit equipment. 32.2232 Section 32.2232... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2232 Circuit equipment...

  7. 47 CFR 32.2232 - Circuit equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... subaccount 2232.1 Electronic shall include the original cost of electronic circuit equipment. (c) This... 47 Telecommunication 2 2012-10-01 2012-10-01 false Circuit equipment. 32.2232 Section 32.2232... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2232 Circuit equipment...

  8. 47 CFR 32.2232 - Circuit equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... subaccount 2232.1 Electronic shall include the original cost of electronic circuit equipment. (c) This... 47 Telecommunication 2 2010-10-01 2010-10-01 false Circuit equipment. 32.2232 Section 32.2232... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2232 Circuit equipment...

  9. 47 CFR 32.2232 - Circuit equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... subaccount 2232.1 Electronic shall include the original cost of electronic circuit equipment. (c) This... 47 Telecommunication 2 2013-10-01 2013-10-01 false Circuit equipment. 32.2232 Section 32.2232... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2232 Circuit equipment...

  10. 47 CFR 32.2232 - Circuit equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... subaccount 2232.1 Electronic shall include the original cost of electronic circuit equipment. (c) This... 47 Telecommunication 2 2014-10-01 2014-10-01 false Circuit equipment. 32.2232 Section 32.2232... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2232 Circuit equipment...

  11. Factors affecting quality of life in patients on haemodialysis: a cross-sectional study from Palestine.

    PubMed

    Zyoud, Sa'ed H; Daraghmeh, Dala N; Mezyed, Diana O; Khdeir, Razan L; Sawafta, Mayas N; Ayaseh, Nora A; Tabeeb, Ghada H; Sweileh, Waleed M; Awang, Rahmat; Al-Jabi, Samah W

    2016-04-27

    Haemodialysis (HD) is a life-sustaining treatment for patients with end-stage renal disease (ESRD). HD can bring about significant impairment in health-related quality of life (HRQOL) and outcomes. Therefore, we sought to describe the patterns of HRQOL and determine the independent factors associated with poor HRQOL in Palestinian patients on HD. A multicenter cross-sectional study was performed from June 2014 to January 2015 using the EuroQOL-5 Dimensions instrument (EQ-5D-5L) for the assessment of HRQOL. ESRD patients undergoing HD in all dialysis centres in the West Bank of Palestine were approached and recruited for this study. Multiple linear regression was carried out to identify factors that were significantly associated with HRQOL. Two hundred and sixty-seven patients were participated in the current study giving response rate of 96 %. Overall, 139 (52.1 %) were male, and the mean ± standard deviation age was 53.3 ± 16.2 years. The reported HRQOL as measured by mean EQ-5D-5L index value and Euro QOL visual analogue scale (EQ-VAS) score was 0.37 ± 0.44 and 59.38 ± 45.39, respectively. There was a moderate positive correlation between the EQ-VAS and the EQ-5D-5L index value (r = 0.42, p < 0.001). The results of multiple linear regression showed a significant negative association between HRQOL with age, total number of chronic co-morbid diseases and the total number of chronic medications. However, a significant positive association was found between HRQOL with male gender, university education level and patients who live in village. Our results provided insight into a number of associations between patient variables and their HRQOL. Healthcare providers should be aware of low HRQOL among patients with no formal education, female gender, patient's residents of refugee camps, multiple co-morbid diseases, multiple chronic medications, and elderly patients to improve their quality of life.

  12. [Medical Equipment Maintenance Methods].

    PubMed

    Liu, Hongbin

    2015-09-01

    Due to the high technology and the complexity of medical equipment, as well as to the safety and effectiveness, it determines the high requirements of the medical equipment maintenance work. This paper introduces some basic methods of medical instrument maintenance, including fault tree analysis, node method and exclusive method which are the three important methods in the medical equipment maintenance, through using these three methods for the instruments that have circuit drawings, hardware breakdown maintenance can be done easily. And this paper introduces the processing methods of some special fault conditions, in order to reduce little detours in meeting the same problems. Learning is very important for stuff just engaged in this area.

  13. 21 CFR 211.65 - Equipment construction.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 4 2013-04-01 2013-04-01 false Equipment construction. 211.65 Section 211.65 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Equipment § 211.65 Equipment...

  14. 44 CFR 208.25 - Obsolete equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 44 Emergency Management and Assistance 1 2011-10-01 2011-10-01 false Obsolete equipment. 208.25... Cooperative Agreements § 208.25 Obsolete equipment. (a) The Assistant Administrator will periodically identify obsolete items on the Equipment Cache List and provide such information to Sponsoring Agencies. (b) Neither...

  15. 49 CFR 195.262 - Pumping equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Pumping equipment. 195.262 Section 195.262... PIPELINE Construction § 195.262 Pumping equipment. (a) Adequate ventilation must be provided in pump... provided in each pump station: (1) Safety devices that prevent overpressuring of pumping equipment...

  16. 14 CFR 29.1561 - Safety equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Safety equipment. 29.1561 Section 29.1561 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS....1561 Safety equipment. (a) Each safety equipment control to be operated by the crew in emergency, such...

  17. 14 CFR 27.1561 - Safety equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Safety equipment. 27.1561 Section 27.1561 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... Safety equipment. (a) Each safety equipment control to be operated by the crew in emergency, such as...

  18. 14 CFR 25.1561 - Safety equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Safety equipment. 25.1561 Section 25.1561 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS....1561 Safety equipment. (a) Each safety equipment control to be operated by the crew in emergency, such...

  19. 14 CFR 29.1431 - Electronic equipment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electronic equipment. 29.1431 Section 29... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Miscellaneous Equipment § 29.1431 Electronic... operation of any other radio or electronic unit, or system of units, required by this chapter. ...

  20. 14 CFR 29.1431 - Electronic equipment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electronic equipment. 29.1431 Section 29... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Miscellaneous Equipment § 29.1431 Electronic... operation of any other radio or electronic unit, or system of units, required by this chapter. ...

  1. 14 CFR 29.1431 - Electronic equipment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electronic equipment. 29.1431 Section 29... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Miscellaneous Equipment § 29.1431 Electronic... operation of any other radio or electronic unit, or system of units, required by this chapter. ...

  2. 14 CFR 29.1431 - Electronic equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electronic equipment. 29.1431 Section 29... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Miscellaneous Equipment § 29.1431 Electronic... operation of any other radio or electronic unit, or system of units, required by this chapter. ...

  3. 14 CFR 27.1561 - Safety equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Safety equipment. 27.1561 Section 27.1561 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... Safety equipment. (a) Each safety equipment control to be operated by the crew in emergency, such as...

  4. 14 CFR 29.1561 - Safety equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Safety equipment. 29.1561 Section 29.1561 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS....1561 Safety equipment. (a) Each safety equipment control to be operated by the crew in emergency, such...

  5. 14 CFR 25.1561 - Safety equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Safety equipment. 25.1561 Section 25.1561 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS....1561 Safety equipment. (a) Each safety equipment control to be operated by the crew in emergency, such...

  6. 46 CFR 184.210 - Heating equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Heating equipment. 184.210 Section 184.210 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Cooking and Heating § 184.210 Heating equipment...

  7. 47 CFR 32.2123 - Office equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Office equipment. 32.2123 Section 32.2123... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2123 Office equipment. This account shall include the original cost of office equipment in offices, shops and all other...

  8. 78 FR 59623 - Emergency Medical Equipment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-27

    .... FAA-2000-7119] RIN 2120-AG89 Emergency Medical Equipment AGENCY: Federal Aviation Administration (FAA... accordance with the FAA master minimum equipment list does not adversely affect aviation safety. This action... relief for use of emergency medical equipment. DATES: This action becomes effective September 27, 2013...

  9. 30 CFR 75.520 - Electric equipment; switches.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electric equipment; switches. 75.520 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.520 Electric equipment; switches. [Statutory Provision] All electric equipment shall be provided with switches or other...

  10. 30 CFR 75.520 - Electric equipment; switches.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric equipment; switches. 75.520 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.520 Electric equipment; switches. [Statutory Provision] All electric equipment shall be provided with switches or other...

  11. 30 CFR 75.520 - Electric equipment; switches.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electric equipment; switches. 75.520 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.520 Electric equipment; switches. [Statutory Provision] All electric equipment shall be provided with switches or other...

  12. 30 CFR 75.520 - Electric equipment; switches.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electric equipment; switches. 75.520 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.520 Electric equipment; switches. [Statutory Provision] All electric equipment shall be provided with switches or other...

  13. 30 CFR 75.520 - Electric equipment; switches.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electric equipment; switches. 75.520 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.520 Electric equipment; switches. [Statutory Provision] All electric equipment shall be provided with switches or other...

  14. 14 CFR 135.157 - Oxygen equipment requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Oxygen equipment requirements. 135.157... Equipment § 135.157 Oxygen equipment requirements. (a) Unpressurized aircraft. No person may operate an unpressurized aircraft at altitudes prescribed in this section unless it is equipped with enough oxygen...

  15. 14 CFR 135.157 - Oxygen equipment requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Oxygen equipment requirements. 135.157... Equipment § 135.157 Oxygen equipment requirements. (a) Unpressurized aircraft. No person may operate an unpressurized aircraft at altitudes prescribed in this section unless it is equipped with enough oxygen...

  16. 14 CFR 135.157 - Oxygen equipment requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Oxygen equipment requirements. 135.157... Equipment § 135.157 Oxygen equipment requirements. (a) Unpressurized aircraft. No person may operate an unpressurized aircraft at altitudes prescribed in this section unless it is equipped with enough oxygen...

  17. 14 CFR 135.157 - Oxygen equipment requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Oxygen equipment requirements. 135.157... Equipment § 135.157 Oxygen equipment requirements. (a) Unpressurized aircraft. No person may operate an unpressurized aircraft at altitudes prescribed in this section unless it is equipped with enough oxygen...

  18. 14 CFR 135.157 - Oxygen equipment requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Oxygen equipment requirements. 135.157... Equipment § 135.157 Oxygen equipment requirements. (a) Unpressurized aircraft. No person may operate an unpressurized aircraft at altitudes prescribed in this section unless it is equipped with enough oxygen...

  19. 40 CFR 1054.626 - What special provisions apply to equipment imported under the Transition Program for Equipment...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... EMISSIONS FROM NEW, SMALL NONROAD SPARK-IGNITION ENGINES AND EQUIPMENT Special Compliance Provisions § 1054... provisions of this section and send us an annual report, as follows: (1) Notify the Designated Compliance... and manufacturing equipment. Companies that import equipment into the United States without meeting...

  20. 30 CFR 77.507 - Electric equipment; switches.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electric equipment; switches. 77.507 Section 77.507 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND... Electrical Equipment-General § 77.507 Electric equipment; switches. All electric equipment shall be provided...

  1. 30 CFR 77.507 - Electric equipment; switches.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electric equipment; switches. 77.507 Section 77.507 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND... Electrical Equipment-General § 77.507 Electric equipment; switches. All electric equipment shall be provided...

  2. 30 CFR 77.507 - Electric equipment; switches.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electric equipment; switches. 77.507 Section 77.507 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND... Electrical Equipment-General § 77.507 Electric equipment; switches. All electric equipment shall be provided...

  3. 30 CFR 77.507 - Electric equipment; switches.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electric equipment; switches. 77.507 Section 77.507 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND... Electrical Equipment-General § 77.507 Electric equipment; switches. All electric equipment shall be provided...

  4. 30 CFR 77.507 - Electric equipment; switches.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric equipment; switches. 77.507 Section 77.507 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND... Electrical Equipment-General § 77.507 Electric equipment; switches. All electric equipment shall be provided...

  5. 49 CFR 195.262 - Pumping equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PIPELINE Construction § 195.262 Pumping equipment. (a) Adequate ventilation must be provided in pump... provided in each pump station: (1) Safety devices that prevent overpressuring of pumping equipment..., pumping equipment must be installed on property that is under the control of the operator and at least 15...

  6. 49 CFR 195.262 - Pumping equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PIPELINE Construction § 195.262 Pumping equipment. (a) Adequate ventilation must be provided in pump... provided in each pump station: (1) Safety devices that prevent overpressuring of pumping equipment..., pumping equipment must be installed on property that is under the control of the operator and at least 15...

  7. 49 CFR 195.262 - Pumping equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PIPELINE Construction § 195.262 Pumping equipment. (a) Adequate ventilation must be provided in pump... provided in each pump station: (1) Safety devices that prevent overpressuring of pumping equipment..., pumping equipment must be installed on property that is under the control of the operator and at least 15...

  8. 49 CFR 195.262 - Pumping equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PIPELINE Construction § 195.262 Pumping equipment. (a) Adequate ventilation must be provided in pump... provided in each pump station: (1) Safety devices that prevent overpressuring of pumping equipment..., pumping equipment must be installed on property that is under the control of the operator and at least 15...

  9. 47 CFR 73.1610 - Equipment tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Equipment tests. 73.1610 Section 73.1610... Rules Applicable to All Broadcast Stations § 73.1610 Equipment tests. (a) During the process of..., without further authority from the FCC, conduct equipment tests for the purpose of making such adjustments...

  10. 47 CFR 74.151 - Equipment changes.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Equipment changes. 74.151 Section 74.151....151 Equipment changes. The licensee of an experimental broadcast station may make any changes in the equipment that are deemed desirable or necessary provided: (a) That the operating frequency is not permitted...

  11. 10 CFR 431.404 - Imported equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Imported equipment. 431.404 Section 431.404 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT General Provisions § 431.404 Imported equipment. (a) Under sections 331 and 345 of the Act, any...

  12. 47 CFR 73.1610 - Equipment tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Equipment tests. 73.1610 Section 73.1610... Rules Applicable to All Broadcast Stations § 73.1610 Equipment tests. (a) During the process of..., without further authority from the FCC, conduct equipment tests for the purpose of making such adjustments...

  13. 47 CFR 73.1610 - Equipment tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Equipment tests. 73.1610 Section 73.1610... Rules Applicable to All Broadcast Stations § 73.1610 Equipment tests. (a) During the process of..., without further authority from the FCC, conduct equipment tests for the purpose of making such adjustments...

  14. 46 CFR 184.220 - Cooking equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Cooking equipment. 184.220 Section 184.220 Shipping...) VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Cooking and Heating § 184.220 Cooking equipment. (a) Doors on a cooking appliance must be provided with hinges and locking devices to prevent...

  15. New Trends in School Science Equipment.

    ERIC Educational Resources Information Center

    Lowe, Norman K., Ed.

    This four-part volume examines trends, problems, and issues related to school science equipment. Part 1 focuses on laboratory work and practical activities in science and technology education, considering equipment and curriculum development, equipment development related to curricula in Brazil, uses of local resources for practical work,…

  16. Inexpensive Physical Education Equipment for Children.

    ERIC Educational Resources Information Center

    Werner, Peter H.; Simmons, Richard A.

    This book presents ideas for constructing and utilizing homemade recreational equipment for elementary school children. Each chapter deals with acquisition of materials, construction of equipment, and developmental objectives and activities for using the equipment with children. A chapter called "Save Your Junk" gives instructions on how to make…

  17. [Home hemodialysis: the technical overview. A 2010 survey].

    PubMed

    Ponson, Laurent; Arkouche, Walid; Laville, Maurice

    2012-04-01

    Compared to the daily work in dialysis units, home haemodialysis represents a particular task for the technical services of healthcare facilities. This survey concerns this modality of treatment of end-stage chronic renal failure, and was led to three objectives: to make a snapshot of the practices done by the technical staff, to point out significant differences, and to identify common issues. This is also an opportunity to discuss about the future of this treatment. Numbers of registries show a continuous decline of home haemodialysis during past decades. This could be explained by many factors, but on the other hand several points tend to forecast a renewed interest for this method of treatment. A questionnaire was sent to every technical service of health organizations dispensing dialysis in France. Seventeen health facilities providing home haemodialysis have sent back their information, representing 238 patients, that to say almost the totality of the patients of the country. These data were analysed, relevant indicators were sorted out, so that initial objectives could be completed. The results are explained as follows: site activities, procedures before and during patient installation, equipment, preventive visits, and corrective maintenance. In lack of a precise regulation on the technical support of these patients, significant differences of operations were noted and are detailed, as well as several common difficulties. All these elements can be used as a basis for the development of a practical guide intended to technical services. This work is voluntarily centered on the technical aspects, but other levers exist to revitalize this method. Copyright © 2012 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.

  18. Implementation of a novel in vitro model of infection of reconstituted human epithelium for expression of virulence genes in methicillin-resistant Staphylococcus aureus strains isolated from catheter-related infections in Mexico

    PubMed Central

    2014-01-01

    Background Methicillin-resistant Staphylococcus aureus (MRSA) are clinically relevant pathogens that cause severe catheter-related nosocomial infections driven by several virulence factors. Methods We implemented a novel model of infection in vitro of reconstituted human epithelium (RHE) to analyze the expression patterns of virulence genes in 21 MRSA strains isolated from catheter-related infections in Mexican patients undergoing haemodialysis. We also determined the phenotypic and genotypic co-occurrence of antibiotic- and disinfectant-resistance traits in the S. aureus strains, which were also analysed by pulsed-field-gel electrophoresis (PFGE). Results In this study, MRSA strains isolated from haemodialysis catheter-related infections expressed virulence markers that mediate adhesion to, and invasion of, RHE. The most frequent pattern of expression (present in 47.6% of the strains) was as follows: fnbA, fnbB, spa, clfA, clfB, cna, bbp, ebps, eap, sdrC, sdrD, sdrE, efb, icaA, and agr. Seventy-one percent of the strains harboured the antibiotic- and disinfectant-resistance genes ermA, ermB, tet(M), tet(K), blaZ, qacA, qacB, and qacC. PFGE of the isolated MRSA revealed three identical strains and two pairs of identical strains. The strains with identical PFGE patterns showed the same phenotypes and genotypes, including the same spa type (t895), suggesting hospital personnel manipulating the haemodialysis equipment could be the source of catheter contamination. Conclusion These findings help define the prevalence of MRSA virulence factors in catheter-related infections. Some of the products of the expressed genes that we detected in this work may serve as potential antigens for inclusion in a vaccine for the prevention of MRSA-catheter-related infections. PMID:24405688

  19. 46 CFR 153.215 - Safety equipment lockers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Safety equipment lockers. 153.215 Section 153.215... Vessel Requirements § 153.215 Safety equipment lockers. Each self-propelled ship must have the following: (a) Each tankship must have at least two safety equipment lockers. (b) One safety equipment locker...

  20. 46 CFR 153.215 - Safety equipment lockers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Safety equipment lockers. 153.215 Section 153.215... Vessel Requirements § 153.215 Safety equipment lockers. Each self-propelled ship must have the following: (a) Each tankship must have at least two safety equipment lockers. (b) One safety equipment locker...

  1. 46 CFR 153.215 - Safety equipment lockers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Safety equipment lockers. 153.215 Section 153.215... Vessel Requirements § 153.215 Safety equipment lockers. Each self-propelled ship must have the following: (a) Each tankship must have at least two safety equipment lockers. (b) One safety equipment locker...

  2. 46 CFR 153.215 - Safety equipment lockers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Safety equipment lockers. 153.215 Section 153.215... Vessel Requirements § 153.215 Safety equipment lockers. Each self-propelled ship must have the following: (a) Each tankship must have at least two safety equipment lockers. (b) One safety equipment locker...

  3. 46 CFR 153.215 - Safety equipment lockers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Safety equipment lockers. 153.215 Section 153.215... Vessel Requirements § 153.215 Safety equipment lockers. Each self-propelled ship must have the following: (a) Each tankship must have at least two safety equipment lockers. (b) One safety equipment locker...

  4. 46 CFR 108.719 - Pilot boarding equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Pilot boarding equipment. 108.719 Section 108.719... AND EQUIPMENT Miscellaneous Equipment § 108.719 Pilot boarding equipment. (a) This section applies to each vessel that normally embarks or disembarks a pilot from a pilot boat or other vessel. (b) Each...

  5. 46 CFR 108.719 - Pilot boarding equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Pilot boarding equipment. 108.719 Section 108.719... AND EQUIPMENT Miscellaneous Equipment § 108.719 Pilot boarding equipment. (a) This section applies to each vessel that normally embarks or disembarks a pilot from a pilot boat or other vessel. (b) Each...

  6. 47 CFR 78.23 - Equipment tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Equipment tests. 78.23 Section 78.23... SERVICE Applications and Licenses § 78.23 Equipment tests. (a) Following the grant of a CARS license, the... Commission, conduct equipment tests for the purpose of such adjustments and measurements as may be necessary...

  7. 47 CFR 78.23 - Equipment tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Equipment tests. 78.23 Section 78.23... SERVICE Applications and Licenses § 78.23 Equipment tests. (a) Following the grant of a CARS license, the... Commission, conduct equipment tests for the purpose of such adjustments and measurements as may be necessary...

  8. 47 CFR 78.23 - Equipment tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Equipment tests. 78.23 Section 78.23... SERVICE Applications and Licenses § 78.23 Equipment tests. (a) Following the grant of a CARS license, the... Commission, conduct equipment tests for the purpose of such adjustments and measurements as may be necessary...

  9. 30 CFR 77.1914 - Electrical equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electrical equipment. 77.1914 Section 77.1914... Shaft Sinking § 77.1914 Electrical equipment. (a) Electric equipment employed below the collar of a.... (b) The insulation of all electric conductors employed below the collar of any slope or shaft during...

  10. 30 CFR 77.1914 - Electrical equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electrical equipment. 77.1914 Section 77.1914... Shaft Sinking § 77.1914 Electrical equipment. (a) Electric equipment employed below the collar of a.... (b) The insulation of all electric conductors employed below the collar of any slope or shaft during...

  11. 30 CFR 77.1914 - Electrical equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electrical equipment. 77.1914 Section 77.1914... Shaft Sinking § 77.1914 Electrical equipment. (a) Electric equipment employed below the collar of a.... (b) The insulation of all electric conductors employed below the collar of any slope or shaft during...

  12. 30 CFR 77.1914 - Electrical equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electrical equipment. 77.1914 Section 77.1914... Shaft Sinking § 77.1914 Electrical equipment. (a) Electric equipment employed below the collar of a.... (b) The insulation of all electric conductors employed below the collar of any slope or shaft during...

  13. 30 CFR 77.1914 - Electrical equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electrical equipment. 77.1914 Section 77.1914... Shaft Sinking § 77.1914 Electrical equipment. (a) Electric equipment employed below the collar of a.... (b) The insulation of all electric conductors employed below the collar of any slope or shaft during...

  14. 46 CFR 28.405 - Hydraulic equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... than four times the system maximum operating pressure. (c) Each hydraulic system must be equipped with... 46 Shipping 1 2013-10-01 2013-10-01 false Hydraulic equipment. 28.405 Section 28.405 Shipping... Operate With More Than 16 Individuals on Board § 28.405 Hydraulic equipment. (a) Each hydraulic system...

  15. 46 CFR 28.405 - Hydraulic equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... than four times the system maximum operating pressure. (c) Each hydraulic system must be equipped with... 46 Shipping 1 2010-10-01 2010-10-01 false Hydraulic equipment. 28.405 Section 28.405 Shipping... Operate With More Than 16 Individuals on Board § 28.405 Hydraulic equipment. (a) Each hydraulic system...

  16. 46 CFR 28.405 - Hydraulic equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... than four times the system maximum operating pressure. (c) Each hydraulic system must be equipped with... 46 Shipping 1 2014-10-01 2014-10-01 false Hydraulic equipment. 28.405 Section 28.405 Shipping... Operate With More Than 16 Individuals on Board § 28.405 Hydraulic equipment. (a) Each hydraulic system...

  17. 46 CFR 28.405 - Hydraulic equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... than four times the system maximum operating pressure. (c) Each hydraulic system must be equipped with... 46 Shipping 1 2011-10-01 2011-10-01 false Hydraulic equipment. 28.405 Section 28.405 Shipping... Operate With More Than 16 Individuals on Board § 28.405 Hydraulic equipment. (a) Each hydraulic system...

  18. 46 CFR 28.405 - Hydraulic equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... than four times the system maximum operating pressure. (c) Each hydraulic system must be equipped with... 46 Shipping 1 2012-10-01 2012-10-01 false Hydraulic equipment. 28.405 Section 28.405 Shipping... Operate With More Than 16 Individuals on Board § 28.405 Hydraulic equipment. (a) Each hydraulic system...

  19. The Cost of Maintaining Educational Communications Equipment.

    ERIC Educational Resources Information Center

    Humphrey, David A.

    Tentative formulas for calculating the cost of maintaining educational communications equipment are proposed. The formulas are based on a survey of campuses of the State University of New York. The survey analyzed the types of equipment to be maintained, types of maintenance, who uses the equipment, who services the equipment, and the cost…

  20. Protective equipment use among female rugby players.

    PubMed

    Comstock, R Dawn; Fields, Sarah K; Knox, Christy L

    2005-07-01

    Our objective was to assess the prevalence of protective equipment use and the motivation for using protective equipment among a sample of US female rugby players. We surveyed a convenience sample of 234 current US female rugby players from 14 teams participating in a US women's rugby tournament, obtaining self-reported demographic, rugby exposure, and protective equipment use information. Mouthguards were the most commonly used piece of protective equipment: 90.8% of players reported having always worn a mouthguard while playing or practicing rugby within their most recent 3 months of play. Fewer than 15% of players reported having always worn other types of protective equipment. Equipment use varied by playing position. Whereas over 80% of players in all other positions always wore a mouthguard, 66.7% of scrum halves reported always wearing one. Both backs and forwards reported wearing shoulder pads, but only forwards reported always wearing padded headgear. Mouthguards, padded headgear, and shoulder pads were worn "to prevent injury," whereas ankle braces, neoprene sleeves, and athletic tape on joints were worn "to protect a current/recent injury." This is the first study of female rugby players to assess the prevalence of protective equipment use by playing position and the motivation for using protective equipment. With the exception of mouthguards, US female rugby players infrequently use protective equipment. Protective equipment use varies by playing position. Some types of protective equipment appear to be used as primary prevention mechanisms, whereas others are used as secondary or tertiary prevention mechanisms.