Sample records for haemodynamic measurements continuous

  1. Influence of continuous haemofiltration-related hypothermia on haemodynamic variables and gas exchange in septic patients.

    PubMed

    Matamis, D; Tsagourias, M; Koletsos, K; Riggos, D; Mavromatidis, K; Sombolos, K; Bursztein, S

    1994-07-01

    To investigate the influence of continuous haemofiltration (CHF) on haemodynamics, gas exchange and core temperature in critically ill septic patients with acute renal failure. In 20 patients (17 male, 3 female) ultrafiltration rate, core temperature, gas exchange and haemodynamic variables were measured at regular intervals during the first 48 h of haemofiltration. Baseline data were compared to those obtained 30 min after initiating CHF and also to those during hypothermia (if observed). Haemodynamic variables remained remarkably constant throughout the study period. In patients with a relatively low ultrafiltration rate (855 +/- 278 ml/h) temperature did not change, while in patients with a high ultrafiltration rate (1468 +/- 293 ml/h) core temperature significantly decreased from 37.6 +/- 0.9 degrees C to 34.8 +/- 0.8 degrees C (p < 0.001). There was a statistically significant correlation between temperature decrease and ultrafiltration rate (r = -0.68, Y = 1.8-0.003 X, p < 0.01). Hypothermic patients also showed a mean decrease in VO2 from 141 +/- 22 ml/min/m2 to 112 +/- 22 ml/min/m2 (p < 0.01) with a concomitant increase in PaO2 from 103 +/- 37 mmHg to 140 +/- 42 mmHg (p < 0.001) and in PvO2 from 35 +/- 4 mmHg to 41 +/- 5 mmHg (p < 0.001). 1) Continuous haemofiltration does not cause significant alternations in haemodynamic variables. 2) Hypothermia frequently occurs in patients undergoing continuous haemofiltration with high ultrafiltration rates. These hypothermic patients show a reduction in VO2 leading to an increase in PvO2 and PaO2. This mild hypothermia in these circumstances has no evident deleterious effects.

  2. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring for surgical hip repair in two patients with severe aortic stenosis.

    PubMed

    López, María Mercedes; Guasch, Emilia; Schiraldi, Renato; Maggi, Genaro; Alonso, Eduardo; Gilsanz, Fernando

    2016-01-01

    Aortic stenosis increases perioperative morbidity and mortality, perioperative invasive monitoring is advised for patients with an aortic valve area <1.0 cm(2) or a mean aortic valve gradient >30 mmHg and it is important to avoid hypotension and arrhythmias. We report the anaesthetic management with continuous spinal anaesthesia and minimally invasive haemodynamic monitoring of two patients with severe aortic stenosis undergoing surgical hip repair. Two women with severe aortic stenosis were scheduled for hip fracture repair. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring was used for anaesthetic management of both. Surgery was performed successfully after two consecutive doses of 2mg of isobaric bupivacaine 0.5% in one of them and four consecutive doses in the other. Haemodynamic conditions remained stable throughout the intervention. Vital signs and haemodynamic parameters remained stable throughout the two interventions. Our report illustrates the use of continuous spinal anaesthesia with minimally invasive haemodynamic monitoring as a valid alternative to general or epidural anaesthesia in two patients with severe aortic stenosis who are undergoing lower limb surgery. However, controlled clinical trials would be required to establish that this technique is safe and effective in these type or patients. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  3. Non-invasive measurement of the haemodynamic effects of inhaled salbutamol, intravenous L-arginine and sublingual nitroglycerin

    PubMed Central

    Tahvanainen, Anna; Leskinen, Miia; Koskela, Jenni; Ilveskoski, Erkki; Alanko, Juha; Kähönen, Mika; Kööbi, Tiit; Lehtimäki, Lauri; Moilanen, Eeva; Mustonen, Jukka; Pörsti, Ilkka

    2009-01-01

    AIMS To examine the effects of salbutamol and L-arginine, two compounds acting largely on the endothelium, and the endothelium-independent agent nitroglycerin on blood pressure, arterial compliance, cardiac function and vascular resistance. METHODS Continuous radial pulse wave analysis, whole-body impedance cardiography, and plethysmographic blood pressure from fingers in the supine position and during head-up tilt were recorded in nine healthy subjects. Data were captured before and after L-arginine (10 mg mg−1 min−1) or saline infusion, salbutamol (400 µg) or placebo inhalation, and sublingual nitroglycerin (0.25 mg) or placebo resoriblet. RESULTS The results of all measurements were comparable before drug administration. The effects of inhaled salbutamol were apparent in the supine position: systemic vascular resistance (−9.2 ± 2.6%) and augmentation index (−4.0 ± 1.5%) decreased, and heart rate (8.6 ± 2.5%) and cardiac output (8.8 ± 3.1%) increased. L-arginine had no clear effects on supine haemodynamics, but during head-up tilt blood pressure was moderately decreased and reduction in aortic reflection time prevented, indicating improved large arterial compliance. Nitroglycerin reduced supine vascular resistance (−6.7 ± 1.8%) and augmentation index (−7.4 ± 1.6%), and increased cardiac output (+9.2 ± 2.7%). During head-up tilt, nitroglycerin increased cardiac output (+10.6 ± 5.6%) and heart rate (+40 ± 7.5%), decreased vascular resistance (−7.8 ± 5.8%) and augmentation index (−18.7 ± 3.2%), and prevented the decrease in aortic reflection time. CONCLUSIONS Inhaled salbutamol predominantly changed supine haemodynamics, whereas the moderate effects of L-arginine were observed during the head-up tilt. In contrast, small doses of nitroglycerin induced major changes in haemodynamics both supine and during the head-up tilt. Altogether, these results emphasize the importance of haemodynamic measurements in both the supine and upright

  4. Reflexology has no immediate haemodynamic effect in patients with chronic heart failure: a double blind randomised controlled trial.

    PubMed

    Jones, Jenny; Thomson, Patricia; Lauder, William; Howie, Kate; Leslie, Stephen J

    2013-08-01

    This study measured the effects of reflexology in 12 reflexology-naive patients with chronic heart failure in a placebo-controlled, double blind randomised controlled study design. Outcomes included 'beat-to-beat' non-invasive continuous measurement of cardiovascular parameters and measurement of state of anxiety and pain/discomfort. There were no changes in any of the haemodynamic parameters measured (all p > 0.05). Perceived state of anxiety was significantly reduced post treatment in the control group only (p = 0.03). Reflexology applied to the feet of patients with chronic heart failure appears to have no immediate haemodynamic effects. While any long term treatment effect is uncertain, it would appear that reflexology is safe for use in this patient group. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Household air pollution and measures of blood pressure, arterial stiffness and central haemodynamics.

    PubMed

    Baumgartner, Jill; Carter, Ellison; Schauer, James J; Ezzati, Majid; Daskalopoulou, Stella S; Valois, Marie-France; Shan, Ming; Yang, Xudong

    2018-02-09

    We evaluated the exposure-response associations between personal exposure to air pollution from biomass stoves and multiple vascular and haemodynamic parameters in rural Chinese women. We analysed the baseline information from a longitudinal study in southwestern China. Women's brachial and central blood pressure and pulse pressure, carotid-femoral pulse wave velocity and augmentation index, and their 48-hour personal exposures to fine particulate matter (PM 2.5 ) and black carbon were measured in summer and winter. We evaluated the associations between exposure to air pollution and haemodynamic parameters using mixed-effects regression models adjusted for known cardiovascular risk factors. Women's (n=205, ages 27-86 years) exposures to PM 2.5 and black carbon ranged from 14 µg/m 3 to 1405 µg/m 3 and 0.1-121.8 µg/m 3 , respectively. Among women aged ≥50 years, increased PM 2.5 exposure was associated with higher systolic (brachial: 3.5 mm Hg (P=0.05); central: 4.4 mm Hg (P=0.005)) and diastolic blood pressure (central: 1.3 mm Hg (P=0.10)), higher pulse pressure (peripheral: 2.5 mm Hg (P=0.05); central: 2.9 mm Hg (P=0.008)) and lower peripheral-central pulse pressure amplification (-0.007 (P=0.04)). Among younger women, the associations were inconsistent in the direction of effect and not statistically significant. Increased PM 2.5 exposure was associated with no difference in pulse wave velocity and modestly higher augmentation index though the CI included zero (1.1%; 95% CI -0.2% to 2.4%). Similar associations were found for black carbon exposure. Exposure to household air pollution was associated with higher blood pressure and central haemodynamics in older Chinese women, with no associations observed with pulse wave velocity. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Ketamine modulation of the haemodynamic response to spreading depolarization in the gyrencephalic swine brain

    PubMed Central

    Santos, Edgar; Schöll, Michael; Kunzmann, Kevin; Stock, Christian; Silos, Humberto; Unterberg, Andreas W; Sakowitz, Oliver W

    2016-01-01

    Spreading depolarization (SD) generates significant alterations in cerebral haemodynamics, which can have detrimental consequences on brain function and integrity. Ketamine has shown an important capacity to modulate SD; however, its impact on SD haemodynamic response is incompletely understood. We investigated the effect of two therapeutic ketamine dosages, a low-dose of 2 mg/kg/h and a high-dose of 4 mg/kg/h, on the haemodynamic response to SD in the gyrencephalic swine brain. Cerebral blood volume, pial arterial diameter and cerebral blood flow were assessed through intrinsic optical signal imaging and laser-Doppler flowmetry. Our findings indicate that frequent SDs caused a persistent increase in the baseline pial arterial diameter, which can lead to a diminished capacity to further dilate. Ketamine infused at a low-dose reduced the hyperemic/vasodilative response to SD; however, it did not alter the subsequent oligemic/vasoconstrictive response. This low-dose did not prevent the baseline diameter increase and the diminished dilative capacity. Only infusion of ketamine at a high-dose suppressed SD and the coupled haemodynamic response. Therefore, the haemodynamic response to SD can be modulated by continuous infusion of ketamine. However, its use in pathological models needs to be explored to corroborate its possible clinical benefit. PMID:27126324

  7. Ketamine modulation of the haemodynamic response to spreading depolarization in the gyrencephalic swine brain.

    PubMed

    Sánchez-Porras, Renán; Santos, Edgar; Schöll, Michael; Kunzmann, Kevin; Stock, Christian; Silos, Humberto; Unterberg, Andreas W; Sakowitz, Oliver W

    2017-05-01

    Spreading depolarization (SD) generates significant alterations in cerebral haemodynamics, which can have detrimental consequences on brain function and integrity. Ketamine has shown an important capacity to modulate SD; however, its impact on SD haemodynamic response is incompletely understood. We investigated the effect of two therapeutic ketamine dosages, a low-dose of 2 mg/kg/h and a high-dose of 4 mg/kg/h, on the haemodynamic response to SD in the gyrencephalic swine brain. Cerebral blood volume, pial arterial diameter and cerebral blood flow were assessed through intrinsic optical signal imaging and laser-Doppler flowmetry. Our findings indicate that frequent SDs caused a persistent increase in the baseline pial arterial diameter, which can lead to a diminished capacity to further dilate. Ketamine infused at a low-dose reduced the hyperemic/vasodilative response to SD; however, it did not alter the subsequent oligemic/vasoconstrictive response. This low-dose did not prevent the baseline diameter increase and the diminished dilative capacity. Only infusion of ketamine at a high-dose suppressed SD and the coupled haemodynamic response. Therefore, the haemodynamic response to SD can be modulated by continuous infusion of ketamine. However, its use in pathological models needs to be explored to corroborate its possible clinical benefit.

  8. Tissue oxygenation and haemodynamics measurement with spatially resolved NIRS

    NASA Astrophysics Data System (ADS)

    Zhang, Y.; Scopesi, F.; Serra, G.; Sun, J. W.; Rolfe, P.

    2010-08-01

    We describe the use of Near Infrared Spectroscopy (NIRS) for the non-invasive investigation of changes in haemodynamics and oxygenation of human peripheral tissues. The goal was to measure spatial variations of tissue NIRS oxygenation variables, namely deoxy-haemoglobin (HHb), oxy-haemoglobin (HbO2), total haemoglobin (HbT), and thereby to evaluate the responses of the peripheral circulation to imposed physiological challenges. We present a skinfat- muscle heterogeneous tissue model with varying fat thickness up to 15mm and a Monte Carlo simulation of photon transport within this model. The mean partial path length and the mean photon visit depth in the muscle layer were derived for different source-detector spacing. We constructed NIRS instrumentation comprising of light-emitting diodes (LED) as light sources at four wavelengths, 735nm, 760nm, 810nm and 850nm and sensitive photodiodes (PD) as the detectors. Source-detector spacing was varied to perform measurements at different depths within forearm tissue. Changes in chromophore concentration in response to venous and arterial occlusion were calculated using the modified Lambert-Beer Law. Studies in fat and thin volunteers indicated greater sensitivity in the thinner subjects for the tissue oxygenation measurement in the muscle layer. These results were consistent with those found using Monte Carlo simulation. Overall, the results of this investigation demonstrate the usefulness of the NIRS instrument for deriving spatial information from biological tissues.

  9. Haemodynamic and anatomic progression of aortic stenosis.

    PubMed

    Nguyen, Virginia; Cimadevilla, Claire; Estellat, Candice; Codogno, Isabelle; Huart, Virginie; Benessiano, Joelle; Duval, Xavier; Pibarot, Philippe; Clavel, Marie Annick; Enriquez-Sarano, Maurice; Vahanian, Alec; Messika-Zeitoun, David

    2015-06-01

    Aortic valve stenosis (AS) is a progressive disease, but the impact of baseline AS haemodynamic or anatomic severity on AS progression remains unclear. In 149 patients (104 mild AS, 36 moderate AS and 9 severe AS) enrolled in 2 ongoing prospective cohorts (COFRASA/GENERAC), we evaluated AS haemodynamic severity at baseline and yearly, thereafter, using echocardiography (mean pressure gradient (MPG)) and AS anatomic severity using CT (degree of aortic valve calcification (AVC)). After a mean follow-up of 2.9±1.0 years, mean MGP increased from 22±11 to 30±16 mm Hg (+3±3 mm Hg/year), and mean AVC from 1108±891 to 1640±1251 AU (arbitrary units) (+188±176 AU/year). Progression of AS was strongly related to baseline haemodynamic severity (+2±3 mm Hg/year in mild AS, +4±3 mm Hg/year in moderate AS and +5±5 mm Hg/year in severe AS (p=0.01)), and baseline haemodynamic severity was an independent predictor of haemodynamic progression (p=0.0003). Annualised haemodynamic and anatomic progression rates were significantly correlated (r=0.55, p<0.0001), but AVC progression rate was also significantly associated with baseline haemodynamic severity (+141±133 AU/year in mild AS, +279±189 AU/year in moderate AS and +361±293 AU/year in severe AS, p<0.0001), and both baseline MPG and baseline AVC were independent determinants of AVC progression (p<0.0001). AS progressed faster with increasing haemodynamic or anatomic severity. Our results suggest that a medical strategy aimed at preventing AVC progression may be useful in all subsets of patients with AS including those with severe AS and support the recommended closer follow-up of patients with AS as AS severity increases. COFRASA (clinicalTrial.gov number NCT 00338676) and GENERAC (clinicalTrial.gov number NCT00647088). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  10. Haemodynamics, dyspnoea, and pulmonary reserve in heart failure with preserved ejection fraction.

    PubMed

    Obokata, Masaru; Olson, Thomas P; Reddy, Yogesh N V; Melenovsky, Vojtech; Kane, Garvan C; Borlaug, Barry A

    2018-05-19

    Increases in left ventricular filling pressure are a fundamental haemodynamic abnormality in heart failure with preserved ejection fraction (HFpEF). However, very little is known regarding how elevated filling pressures cause pulmonary abnormalities or symptoms of dyspnoea. We sought to determine the relationships between simultaneously measured central haemodynamics, symptoms, and lung ventilatory and gas exchange abnormalities during exercise in HFpEF. Subjects with invasively-proven HFpEF (n = 50) and non-cardiac causes of dyspnoea (controls, n = 24) underwent cardiac catheterization at rest and during exercise with simultaneous expired gas analysis. During submaximal (20 W) exercise, subjects with HFpEF displayed higher pulmonary capillary wedge pressures (PCWP) and pulmonary artery pressures, higher Borg perceived dyspnoea scores, and increased ventilatory drive and respiratory rate. At peak exercise, ventilation reserve was reduced in HFpEF compared with controls, with greater dead space ventilation (higher VD/VT). Increasing exercise PCWP was directly correlated with higher perceived dyspnoea scores, lower peak exercise capacity, greater ventilatory drive, worse New York Heart Association (NYHA) functional class, and impaired pulmonary ventilation reserve. This study provides the first evidence linking altered exercise haemodynamics to pulmonary abnormalities and symptoms of dyspnoea in patients with HFpEF. Further study is required to identify the mechanisms by which haemodynamic derangements affect lung function and symptoms and to test novel therapies targeting exercise haemodynamics in HFpEF.

  11. Relation between exercise central haemodynamic response and resting cardiac structure and function in young healthy men.

    PubMed

    Babcock, Matthew C; Lefferts, Wesley K; Heffernan, Kevin S

    2017-07-01

    Left ventricular (LV) structure and function are predictors of cardiovascular (CV) morbidity and mortality and are related to resting peripheral haemodynamic load in older adults. The central haemodynamic response to exercise may reveal associations with LV structure and function not detected by traditional peripheral (brachial) measures in a younger population. To examine correlations between acute exercise-induced changes in central artery stiffness and wave reflections and measures of resting LV structure and function. Sixteen healthy men (age 26 ± 6 year; BMI 25·3 ± 2·7 kg m -2 ) had measures of central haemodynamic load measured before/after a 30-s Wingate anaerobic test (WAT). Common carotid artery stiffness and reflected wave intensity were assessed via wave intensity analysis as a regional pulse wave velocity (PWV) and negative area (NA), respectively. Resting LV structure (LV mass) and function [midwall fractional shortening (mFS)] were assessed using M-mode echocardiography in the parasternal short-axis view. There was a significant association between mFS and WAT-mediated change in carotid systolic BP (r = -0·57, P = 0·011), logNA (r = -0·58, P = 0·009) and PWV (r = -0·44, P = 0·045). There were no significant associations between resting mFS and changes in brachial systolic BP (r = -0·26, P>0·05). There were no associations between resting LV mass and changes in any haemodynamic variable (P>0·05). Exercise-induced increases in central haemodynamic load reveal associations with lower resting LV function in young healthy men undetected by traditional peripheral haemodynamics. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  12. Shock-like haemodynamic responses induced in the primary visual cortex by moving visual stimuli

    PubMed Central

    Robinson, P. A.

    2016-01-01

    It is shown that recently discovered haemodynamic waves can form shock-like fronts when driven by stimuli that excite the cortex in a patch that moves faster than the haemodynamic wave velocity. If stimuli are chosen in order to induce shock-like behaviour, the resulting blood oxygen level-dependent (BOLD) response is enhanced, thereby improving the signal to noise ratio of measurements made with functional magnetic resonance imaging. A spatio-temporal haemodynamic model is extended to calculate the BOLD response and determine the main properties of waves induced by moving stimuli. From this, the optimal conditions for stimulating shock-like responses are determined, and ways of inducing these responses in experiments are demonstrated in a pilot study. PMID:27974572

  13. Haemodynamic coherence - The relevance of fluid therapy.

    PubMed

    Arnemann, Philip; Seidel, Laura; Ertmer, Christian

    2016-12-01

    The ultimate goal of fluid therapy is to improve the oxygenation of cells by improving the cardiac output, thus improving microcirculation by optimizing macrocirculation. This haemodynamic coherence is often altered in patients with haemorrhagic shock and sepsis. The loss of haemodynamic coherence is associated with adverse outcomes. It may be influenced by the mechanisms of the underlying disease and properties of different fluids used for resuscitation in these critically ill patients. Monitoring microcirculation and haemodynamic coherence may be an additional tool to predict the response to fluid administration. In addition, microcirculatory analysis may support the clinician in his decision to not administer fluids when microcirculatory blood flow is preserved. In future, the indication, guidance and termination of fluid therapy may be assessed by bedside microvascular analysis in combination with standard haemodynamic monitoring. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Relationship between haemodynamic impairment and collateral blood flow in carotid artery disease.

    PubMed

    Hartkamp, Nolan S; Petersen, Esben T; Chappell, Michael A; Okell, Thomas W; Uyttenboogaart, Maarten; Zeebregts, Clark J; Bokkers, Reinoud Ph

    2017-01-01

    Collateral blood flow plays a pivotal role in steno-occlusive internal carotid artery (ICA) disease to prevent irreversible ischaemic damage. Our aim was to investigate the effect of carotid artery disease upon cerebral perfusion and cerebrovascular reactivity and whether haemodynamic impairment is influenced at brain tissue level by the existence of primary and/or secondary collateral. Eighty-eight patients with steno-occlusive ICA disease and 29 healthy controls underwent MR examination. The presence of collaterals was determined with time-of-flight, two-dimensional phase contrast MRA and territorial arterial spin labeling (ASL) imaging. Cerebral blood flow and cerebrovascular reactivity were assessed with ASL before and after acetazolamide. Cerebral haemodynamics were normal in asymptomatic ICA stenosis patients, as opposed to patients with ICA occlusion, in whom the haemodynamics in both hemispheres were compromised. Haemodynamic impairment in the affected brain region was always present in symptomatic patients. The degree of collateral blood flow was inversely correlated with haemodynamic impairment. Recruitment of secondary collaterals only occurred in symptomatic ICA occlusion patients. In conclusion, both CBF and cerebrovascular reactivity were found to be reduced in symptomatic patients with steno-occlusive ICA disease. The presence of collateral flow is associated with further haemodynamic impairment. Recruitment of secondary collaterals is associated with severe haemodynamic impairment.

  15. Pleural effusion decreases left ventricular pre-load and causes haemodynamic compromise: an experimental porcine study.

    PubMed

    Wemmelund, K B; Lie, R H; Juhl-Olsen, P; Frederiksen, C A; Hermansen, J F; Sloth, E

    2012-08-01

    Although pleural effusion is a common complication in critically ill patients, detailed knowledge is missing about the haemodynamic impact and the underlining mechanisms. The aim of this study was to evaluate the haemodynamic effect of incremental pleural effusion by means of invasive haemodynamic parameters and transthoracic echocardiography. This experimental interventional study was conducted using 22 female piglets (17.5-21.5 kg) randomized for right-side (n = 9) and left-side (n = 9) pleural effusion, or sham operation (n = 4). Pleural effusion was induced by infusing incremental volumes of saline into the pleural cavity. Invasive haemodynamic measurements and echocardiographical images were obtained at baseline, a volume of 45 ml/kg, a volume of 75 ml/kg and 45 min after drainage. No difference (all P > 0.147) was found between right- and left-side pleural effusion, and the groups were thus pooled. At 45 ml/kg cardiac output, mean arterial pressure, stroke volume and mixed venous saturation decreased (all P < 0.003); central venous pressure and pulmonary arterial pressure increased (both P > 0.003) at this point. The changes accelerated at 75 ml/kg. At 45 ml/kg left ventricular pre-load in terms of end-diastolic area decreased significantly (P < 0.001). The effect on haemodynamics and cardiac dimensions changed dramatically at 75 ml/kg. Cardiac output, mean arterial pressure, central venous pressure and left ventricular end-diastolic area returned to normal during a recovery period of 45 min (all P > 0.061). Incremental volumes of unilateral pleural effusion induced a significant haemodynamic impact fully reversible after drainage. Pleural effusion causes a significant decrease of left ventricular pre-load in a diverse picture of haemodynamic compromise. © 2012 The Authors. Acta Anaesthesiologica Scandinavica © 2012 The Acta Anaesthesiologica Scandinavica Foundation.

  16. Haemodynamic changes in trauma.

    PubMed

    Kirkman, E; Watts, S

    2014-08-01

    Trauma is the leading cause of death during the first four decades of life in the developed countries. Its haemodynamic response underpins the patient's initial ability to survive, and the response to treatment and subsequent morbidity and resolution. Trauma causes a number of insults including haemorrhage, tissue injury (nociception) and, predominantly, in military casualties, blast from explosions. This article discusses aspects of the haemodynamic responses to these insults and subsequent treatment. 'Simple' haemorrhage (blood loss without significant volume of tissue damage) causes a biphasic response: mean arterial blood pressure (MBP) is initially maintained by the baroreflex (tachycardia and increased vascular resistance, Phase 1), followed by a sudden decrease in MAP initiated by a second reflex (decrease in vascular resistance and bradycardia, Phase 2). Phase 2 may be protective. The response to tissue injury attenuates Phase 2 and may cause a deleterious haemodynamic redistribution that compromises blood flow to some vital organs. In contrast, thoracic blast exposure augments Phase 2 of the response to haemorrhage. However, hypoxaemia from lung injury limits the effectiveness of hypotensive resuscitation by augmenting the attendant shock state. An alternative strategy ('hybrid resuscitation') whereby tissue perfusion is increased after the first hour of hypotensive resuscitation by adopting a revised normotensive target may ameliorate these problems. Finally, morphine also attenuates Phase 2 of the response to haemorrhage in some, but not all, species and this is associated with poor outcome. The impact on human patients is currently unknown and is the subject of a current physiological investigation. © Crown copyright 2014. Published with the permission of the Defence Science and Technology Laboratory on behalf of the Controller of HMSO. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Ocular haemodynamic changes after single treatment with photodynamic therapy assessed with non-invasive techniques.

    PubMed

    Maar, Noemi; Pemp, Berthold; Kircher, Karl; Luksch, Alexandra; Weigert, Günther; Polska, Elzbieta; Tittl, Michael; Stur, Michael; Schmetterer, Leopold

    2009-09-01

    To investigate in patients with neovascular age-related macular degeneration (ARMD) the changes in ocular perfusion caused by single treatment with photodynamic therapy (PDT) by different non-invasive methods; to evaluate correlations between relative changes of ocular haemodynamic parameters after PDT among each other and compared to morphological parameters; and to assess this in relation to early changes of visual acuity. 17 consecutive patients with subfoveal choroidal neovascularization (CNV) caused by ARMD scheduled for PDT without previous PDT treatment (four patients with predominantly classic CNV and 13 patients with occult CNV). best-corrected visual acuity (before PDT, 6 and 8 weeks after PDT), fundus photography, fluorescein angiography, haemodynamic measurements with laser Doppler flowmetry (LDF), laser interferometry and ocular blood flow (OBF) tonometry (baseline and 1, 2, 6 and 8 weeks after treatment). choroidal blood flow (CHBF), fundus pulsation amplitude (FPA), pulsatile ocular blood flow (POBF), visual acuity. Changes smaller than 20% were considered clinically irrelevant. Ocular haemodynamic parameters did not change significantly in the follow-up period. Changes of haemodynamic parameters showed no correlation to treatment spot, morphological changes or visual acuity. Changes of visual acuity were comparable to results of earlier studies. Single treatment with PDT did not modify ocular blood flow parameters above 20% as assessed with different non-invasive methods.

  18. Haemodynamic evidence for cardiac stress during transurethral prostatectomy.

    PubMed Central

    Evans, J. W.; Singer, M.; Chapple, C. R.; Macartney, N.; Walker, J. M.; Milroy, E. J.

    1992-01-01

    OBJECTIVE--To compare haemodynamic performance during transurethral prostatectomy and non-endoscopic control procedures similar in duration and surgical trauma. DESIGN--Controlled comparative study. SETTING--London teaching hospital. PATIENTS--33 men aged 50-85 years in American Society of Anesthesiologists risk groups I and II undergoing transurethral prostatectomy (20), herniorrhaphy (eight), or testicular exploration (five). MAIN OUTCOME MEASURES--Percentage change from baseline in mean arterial pressure, heart rate, Doppler indices of stroke volume and cardiac output, and index of systemic vascular resistance, and change from baseline in core temperature. RESULTS--In the control group mean arterial pressure fell to 11% (95% confidence interval -17% to -5%) below baseline at two minutes into surgery and remained below baseline; there were no other overall changes in haemodynamic variables and the core temperature was stable. During transurethral prostatectomy mean arterial pressure increased by 16% (5% to 27%) at the two minute recording and remained raised throughout. Bradycardia reached -7% (-14% to 1%) by the end of the procedure. Doppler indices of stroke volume fell progressively to 15% (-24% to -6%) below baseline at the end of the procedure, and the index of cardiac output fell to 21% (-32% to -10%) below baseline by the end of the procedure. The index of systemic vascular resistance was increased by 28% (17% to 38%) at two minutes, and by 46.8% (28% to 66%) at the end of the procedure. Core temperature fell by a mean of 0.8 (-1.0 to -0.6) degrees C. Significant differences existed between the two groups in summary measures of mean arterial pressure (p less than 0.05), Doppler indices of stroke volume (p less than 0.005) and cardiac output (p less than 0.005), index of systemic vascular resistance (p less than 0.0005), and core temperature (p less than 0.0001). CONCLUSIONS--Important haemodynamic disturbances were identified during routine apparently

  19. PaCO2 measurement in cerebral haemodynamics: face mask or nasal cannulae?

    PubMed

    Minhas, J S; Robinson, T; Panerai, R

    2017-06-22

    PaCO 2 affects cerebral blood flow (CBF) and its regulatory mechanisms, but the effects of CO 2 measurement technique on cerebrovascular parameters are unknown. In order to determine if the two most commonly used approaches, face mask (FM) or nasal cannulae (NC), are interchangeable or not, we tested the hypothesis that the use of FM versus NC does not lead to significant differences in CO 2 -related systemic and cerebrovascular parameters. Recordings of CBF velocity (CBFV), blood pressure (BP), heart rate, and end-tidal CO 2 (EtCO 2 ) were performed in 42 subjects during normocapnia (FM or NC) and 5% CO 2 inhalation (FM) or hyperventilation (NC). Dynamic cerebral autoregulation was assessed with the autoregulation index (ARI), derived by transfer function analysis from the CBFV response to a hypothetical step change in BP. Significant differences in physiological parameters were seen between FM and NC: EtCO 2 (37.40 versus 35.26 mmHg, p  =  0.001) and heart rate (69.6 versus 66.7 bpm, p  =  0.001) respectively. No differences were observed for mean BP, CBFV or the ARI index. Use of FM or NC for measurement of EtCO 2 leads to physiological changes and differences in parameter values that need to be taken into consideration when interpreting and/or comparing results in studies of cerebral haemodynamics.

  20. Comparison of non-invasive methods for the assessment of haemodynamic drug effects in healthy male and female volunteers: sex differences in cardiovascular responsiveness.

    PubMed Central

    Wolzt, M; Schmetterer, L; Rheinberger, A; Salomon, A; Unfried, C; Breiteneder, H; Ehringer, H; Eichler, H G; Fercher, A F

    1995-01-01

    1. The study was performed to determine the sensitivity and short-term and day-to-day variability of a novel technique based on laser interferometry of ocular fundus pulsations and of non-invasive methods for the quantification of haemodynamic drug effects. An additional aim was to assess sex differences in haemodynamic responsiveness to cardiovascular drugs in male and female healthy volunteers. 2. Ten males and nine females (age range 20-33 years) were studied in a double-blind, randomized, cross-over trial. Simultaneous measurements from systemic haemodynamics, laser interferometry of ocular fundus pulsations, systolic time intervals from mechanocardiography, a/b ratio from oxymetric fingerplethysmography and Doppler sonography of the radial artery were used to describe the haemodynamic effects of cumulative, stepwise increasing intravenous doses of phenylephrine, isoprenaline, sodium nitroprusside and of placebo. 3. Laser interferometry detected the isoprenaline-effects at the lowest dose level of 0.1 micrograms min-1 with a high signal-to-noise ratio. The reproducibility of measurements under baseline was high, no changes were observed after systemically effective doses of phenylephrine or sodium nitroprusside. Systolic time intervals were sensitive and specific for isoprenaline-induced effects, PEP and QS2c-measurements had high reproducibility. Fingerplethysmography proved a sensitive measurement for the detection of the vasodilating effects of sodium nitroprusside, but was not specific, and showed low reproducibility. Measurements from Doppler sonography had lower reproducibility and sensitivity compared with the other applied methods. 4. There was a significant sex difference for several of the haemodynamic parameters under baseline conditions; however, the responsiveness to the drugs under study was not different, when drug effects were expressed as %-change from the baseline. 5. Laser interferometry is a valuable non-invasive, highly sensitive and

  1. Pyridostigmine prevents haemodynamic alterations but does not affect their nycthemeral oscillations in infarcted mice.

    PubMed

    Corrêa, Wesley G; Durand, Marina T; Becari, Christiane; Tezini, Geisa C S V; do Carmo, Jussara M; de Oliveira, Mauro; Prado, Cibele M; Fazan, Rubens; Salgado, Helio C

    2015-01-01

    The increase in acetylcholine yielded by pyridostigmine (PYR), an acetylcholinesterase inhibitor, was evaluated for its effect on the haemodynamic responses-mean arterial pressure (MAP) and heart rate (HR)-and their nycthemeral oscillation in mice before and one week after myocardial infarction (MI). Mice were anesthetized (isoflurane), and a telemetry transmitter was implanted into the carotid artery. After 5 days of recovery, the MAP and HR were recorded for 48 h (10 s every 10 min). Following this procedure, mice were submitted to surgery for sham or coronary artery ligation and received drinking water (VEHICLE) with or without PYR. Five days after surgery, the haemodynamic recordings were recommenced. Sham surgery combined with VEHICLE did not affect basal MAP and HR; nevertheless, these haemodynamic parameters were higher during the night, before and after surgery. MI combined with VEHICLE displayed decreased MAP and increased HR; these haemodynamic parameters were also higher during the night, before and after surgery. Sham surgery combined with PYR displayed similar results for MAP as sham combined with VEHICLE; however, PYR produced bradycardia. Nevertheless, MI combined with PYR exhibited no change in MAP and HR, but these haemodynamic parameters were also higher during the night, before and after surgery. Therefore, MI decreased MAP and increased HR, while PYR prevented these alterations. Neither MI nor PYR affected nycthemeral oscillations of MAP and HR. These findings indicate that the increase in acetylcholine yielded by PYR protected the haemodynamic alterations caused by MI in mice, without affecting the nycthemeral haemodynamic oscillations. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Association of haemodynamic changes measured by serial central venous saturation during ultrafiltration for acutely decompensated heart failure with diuretic resistance and change in renal function.

    PubMed

    Vazir, Ali; Simpkin, Victoria L; Marino, Philip; Ludman, Andrew; Banya, Winston; Tavazzi, Guido; Bastin, Anthony J; Trenfield, Sarah; Ghori, Arshad; Alexander, Peter D; Griffiths, Mark; Price, Susanna; Sharma, Rakesh; Cowie, Martin R

    2016-10-01

    Patients with acute decompensated heart failure with diuretic resistance (ADHF-DR) have a poor prognosis. The aim of this study was to assess in patients with ADHF-DR, whether haemodynamic changes during ultrafiltration (UF) are associated with changes in renal function (Δcreatinine) and whether Δcreatinine post UF is associated with mortality. Seventeen patients with ADHF-DR underwent 20 treatments with UF. Serial bloods (4-6 hourly) from the onset of UF treatment were measured for renal function, electrolytes and central venous saturation (CVO2). Univariate and multivariate analysis were performed to assess the relationship between changes in markers of haemodynamics [heart rate (HR), systolic blood pressure (SBP), packed cell volume (PCV) and CVO2] and Δcreatinine. Patients were followed up and mortality recorded. Cox-regression survival analysis was performed to determine covariates associated with mortality. Renal function worsened after UF in 17 of the 20 UF treatments (baseline vs. post UF creatinine: 164±58 vs. 185±69μmol/l, P<0.01). ΔCVO2 was significantly associated with Δcreatinine [β-coefficient of -1.3 95%CI (-1.8 to -0.7), P<0.001] and remained significantly associated with Δcreatinine after considering changes in SBP, HR and PCV [P<0.001]. Ten (59%) patients died at 1-year and 15(88%) by 2-years. Δcreatinine was independently associated with mortality (adjusted-hazard ratio 1.03 (1.01 to 1.07) per 1μmol/l increase in creatinine; P=0.02). Haemodynamic changes during UF as measured by the surrogate of cardiac output was associated with Δcreatinine. Worsening renal function at end of UF treatment occurred in the majority of patients and was associated with mortality. Copyright © 2016. Published by Elsevier Ireland Ltd.

  3. Haemodynamic responses in chronically painful, human trapezius muscle to cold pressor stimulation.

    PubMed

    Acero, C O; Kuboki, T; Maekawa, K; Yamashita, A; Clark, G T

    1999-10-01

    The aim was to compare haemodynamic responses in trapezius muscles to cold pressor stimulation in individuals with localized trapezius myalgia and asymptomatic controls. Nine males with chronic localized pain in the trapezius (mean age, 23.2 years) and nine male controls (mean age, 24.6 years) who had no medical history of migraine, hypertension or sustained pain in the trapezius region were investigated. Two experimental (cold pressor and mock) trials were performed in a randomly assigned sequence. In the cold pressor trial the participant's left foot and ankle were immersed in 4 degrees C cold water for 2 min; the mock trial was done without that stimulus. Blood volume was continuously recorded 1 min before, 2 min during, and 5 min after cold pressor stimulation using near-infrared spectroscopy. Each participant's blood-volume data were baseline-corrected and submitted to statistical analysis. Results showed that the individuals with muscle pain exhibited a significantly lower mean blood volume than the controls during cold pressor stimulation (p = 0.0367). Upon withdrawal of that stimulation, the mean blood volume in both groups fell below the baseline. These results suggest that individuals with chronic regional trapezius myalgia have less capacity to vasodilate this muscle during cold pressor stimulation than those without such myalgia. It is not yet known if this difference in the haemodynamic response is a cause or an effect of the myalgia.

  4. Laser Echosclerotherapy of varicose veins with haemodynamic echo-doppler evaluation : some rationale and short-term outcomes

    NASA Astrophysics Data System (ADS)

    Vettorello, Gianfranco; Marini, Leonardo

    2009-06-01

    Purpose: The aim is to verify short-term results in Endovenous Laser Treatment (EVLT) performed in haemodynamic way in patients belonging to C2, C3 classes and type I, II, III venous shunts, according respectively with CEAP and Teupitz classification. Methods: Minor changes of technique were applied to EVLT in order to provide haemodynamic conditions. Treatment efficacy, anatomical failure, complications, recurrence rate and clinical improvements were analyzed. 105 limbs were treated from November 2004 to November 2007. Clinical and Echo-Colour-Doppler (ECD) follow up was performed two weeks, one, two and three years after the surgery. Results: in 79 inferior limbs follow-up was concluded and this are the final data: a) no Deep Venous Thrombosis (DVT) was detected; b) a notable reduction of recurrence if compared with groin recurrence rate in traditional stripping; e) satisfactory cosmetic results and short recovery were found in all the patients. Conclusions: In selected patients haemodynamic-guided EVLT is equally safe and efficient than standard. Clinical and aesthetical outcomes are durable without statistical differences on the plan of disease progression and complications. The recurrence rate is lower in EVLT haemodynamic-guided surgery than in conventional stripping. Long-term outcomes should be investigated. We need studies camparison among the three different kind of surgery performed in haemodynamic way

  5. Bitter tastants alter gastric-phase postprandial haemodynamics.

    PubMed

    McMullen, Michael K; Whitehouse, Julie M; Whitton, Peter A; Towell, Anthony

    2014-07-03

    Since Greco-Roman times bitter tastants have been used in Europe to treat digestive disorders, yet no pharmacological mechanism has been identified which can account for this practice. This study investigates whether the bitter tastants, gentian root (Gentian lutea L.) and wormwood herb (Artemisia absinthium L.), stimulate cephalic and/or gut receptors to alter postprandial haemodynamics during the gastric-phase of digestion. Normal participants ingested (1) 100 mL water plus capsules containing either cellulose (placebo-control) or 1000 mg of each tastant (n=14); or (2) 100mL of water flavoured with 500 or 1500 mg of each tastant (a) gentian (n=12) and (b) wormwood (n=12). A single beat-to-beat cardiovascular recording was obtained for the entire session. Pre/post-ingestion contrasts with the control were analysed for (1) the encapsulated tastants, in the "10 to 15" minute post-ingestion period, and (2) the flavoured water in the "5 to 10" minute post-ingestion period. Water, the placebo-control, increased cardiac contraction force and blood pressure notwithstanding heart rate decreases. Encapsulated tastants did not further alter postprandial haemodynamics. In contrast gentian (500 and 1500 mg) and wormwood (1500 mg) flavoured water elicited increased peripheral vascular resistance and decreased cardiac output, primarily by reducing stroke volume rather than heart rate. Drinking 100mL water elicits a pressor effect during the gastric-phase of digestion due to increased cardiac contraction force. The addition of bitter tastants to water elicits an additional and parallel pressor effect due to increased peripheral vascular resistance; yet the extent of the post-prandial blood pressure increases are unchanged, presumably due to baroreflex buffering. The vascular response elicited by bitter tastants can be categorised as a sympathetically-mediated cephalic-phase response. A possible mechanism by which bitter tastants could positively influence digestion is altering

  6. In-line pressure-flow module for in vitro modelling of haemodynamics and biosensor validation

    NASA Technical Reports Server (NTRS)

    Koenig, S. C.; Schaub, J. D.; Ewert, D. L.; Swope, R. D.; Convertino, V. A. (Principal Investigator)

    1997-01-01

    An in-line pressure-flow module for in vitro modelling of haemodynamics and biosensor validation has been developed. Studies show that good accuracy can be achieved in the measurement of pressure and of flow, in steady and pulstile flow systems. The model can be used for development, testing and evaluation of cardiovascular-mechanical-electrical anlogue models, cardiovascular prosthetics (i.e. valves, vascular grafts) and pressure and flow biosensors.

  7. Comparison of the Haemodynamic Effects of Three Different Methods at the Induction of Anaesthesia

    PubMed Central

    Uygur, Mehmet Levent; Ersoy, Ayşın; Altan, Aysel; Ervatan, Zekeriya; Kamalı, Sedat

    2014-01-01

    Objective Haemodynamic variations are inevitable during induction of anaesthetic drugs. The present study investigates the haemodynamic variations of three different drugs (thiopental, propofol, and etomidate) used for induction of general anaesthesia together with fentanyl. Methods In a randomized, double-blind study, 45 patients were assigned to one of three groups (n=15 each). Fentanyl 1 μg kg−1 was injected over 60 sec followed by propofol 2 mg kg−1 (Group P), thiopentone 6 mg kg−1 (Group T), or etomidate 0.3 mg kg−1 (Group E). Noninvasive measurements of systolic arterial pressure (SAP), diastolic arterial pressure (DAP), mean arterial pressure (MAP), and heart rate (HR) was performed on admittance, immediately before the induction of anaesthesia, and 1, 3, and 5 min thereafter. Cardiac output (CO) values were recorded before induction, immediately after the injection of the drug, and at 1 min after the intubation. Results In all groups, during the study period, SAP, DAP, MAP, and CO values decreased with respect to time before induction. Following the administration of the induction dose of propofol (Group P), a significantly greater decrease of systolic and diastolic blood pressure was observed with etomidate (Group E) or thiopentone (Group T). Decrease in CO was also more marked with propofol (Group P) than with etomidate (Group E) or thiopentone (Group T). Conclusion It’s concluded that, in this study, the combination of fentanyl-etomidate is safer than both the groups of fentanyl-propofol and fentanyl-thiopental in terms of providing haemodynamic stability. PMID:27366443

  8. [Effects of liensinine on haemodynamics in rats and the physiologic properties of isolated rabbit atria].

    PubMed

    Wang, J L; Nong, Y; Jing, M X

    1992-01-01

    Liensinine(Lien), an alkaloid extracted from the green seed embryo of Nelumbo nucifera Gaertn, has been shown to have anti-arrhythmic action, its mechanism may be related to blockade of Ca2+, Na+ influx. Lien 3 mg/kg i.v. may temporarily inhibit all parameters of haemodynamics in anesthetized or pithed rats. The inhibitory effects on LVP, +dp/dtmax and SAP in anesthetized rats are slightly stronger than those of quinidine (Qui) 3 mg/kg. Lien 1-30 mg/kg dose-dependently produced these actions. Lien and Qui 12 mg/kg lowered LVP, +dp/dtmax and SAP by 33%, 37%, 29% and 9%, 12%, 9% respectively. While both of them inhibited the other parameters of haemodynamics with nearly equal degrees. The degrees of inhibitory effect of Lien 12 mg/kg on all haemodynamic parameters nearly corresponded to these of verapamil 1 mg/kg. Lien 1-100 mumol/L reduced the contractile force of isolated left atria and the spontaneously beating rate of isolated right atria of rabbits in concentration-dependent manner. These results indicate that the properties of the effect of Lien on haemodynamics may be similar to those of verapamil and different from those of Qui.

  9. Haemodynamics of aerobic and resistance blood flow restriction exercise in young and older adults.

    PubMed

    Staunton, Craig A; May, Anthony K; Brandner, Christopher R; Warmington, Stuart A

    2015-11-01

    Light-load blood flow restriction exercise (BFRE) may provide a novel training method to limit the effects of age-related muscle atrophy in older adults. Therefore, the purpose of this study was to compare the haemodynamic response to resistance and aerobic BFRE between young adults (YA; n = 11; 22 ± 1 years) and older adults (OA; n = 13; 69 ± 1 years). On two occasions, participants completed BFRE or control exercise (CON). One occasion was leg press (LP; 20 % 1-RM) and the other was treadmill walking (TM; 4 km h(-1)). Haemodynamic responses (HR, Q, SV and BP) were recorded during baseline and exercise. At baseline, YA and OA were different for some haemodynamic parameters (e.g. BP, SV). The relative responses to BFRE were similar between YA and OA. Blood pressures increased more with BFRE, and also for LP over TM. Q increased similarly for BFRE and CON (in both LP and TM), but with elevated HR and reduced SV (TM only). While BFR conferred slightly greater haemodynamic stress than CON, this was lower for walking than leg-press exercise. Given similar response magnitudes between YA and OA, these data support aerobic exercise being a more appropriate BFRE for prescription in older adults that may contribute to limiting the effects of age-related muscle atrophy.

  10. Effects of active recovery on autonomic and haemodynamic responses after aerobic exercise.

    PubMed

    Soares, Antonio H G; Oliveira, Tiago P; Cavalcante, Bruno R; Farah, Breno Q; Lima, Aluísio H R A; Cucato, Gabriel G; Cardoso, Crivaldo G; Ritti-Dias, Raphael M

    2017-01-01

    The aim of this study was to examine the effect of active recovery on autonomic and haemodynamic responses after exercise in healthy adults. Nineteen healthy young male individuals underwent two experimental sessions: exercise with active recovery (AR) and exercise with passive recovery (PR). The exercise sessions comprised three phases: warm-up (5 min), exercise phase (cycle ergometer, 30 min, intensity between 60 and 70% of the heart rate reserve) and recovery (5 min). In the AR, the subjects remained cycling in the recovery phase at intensity between 30% and 35% of heart rate reserve, while in the PR, the subjects stopped the exercise after finishing the exercise phase. Blood pressure and heart rate were measured before and over the 30 min after the interventions. There were no differences for systolic and diastolic blood pressures, heart rate and rate pressure product between active and passive recovery sessions. Also, all heart rate variability parameters changed similarly after exercise with passive or active recovery sessions. In summary, exercise with active recovery does not affect the autonomic and haemodynamic responses after moderate-intensity aerobic exercise in healthy young male individuals. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  11. Haemodynamic predictors of a penetrating atherosclerotic ulcer rupture using fluid–structure interaction analysis

    PubMed Central

    D'Ancona, Giuseppe; Amaducci, Andrea; Rinaudo, Antonino; Pasta, Salvatore; Follis, Fabrizio; Pilato, Michele; Baglini, Roberto

    2013-01-01

    We present preliminary data on the flow-induced haemodynamic and structural loads exerted on a penetrating atherosclerotic aortic ulcer (PAU). Specifically, one-way fluid–structure interaction analysis was performed on the aortic model reconstructed from a 66-year-old male patient with a PAU that evolved into an intramural haematoma and rupture of the thoracic aorta. The results show that elevated blood pressure (117 mmHg) and low flow velocity at the aortic wall (0.15 m/s2) occurred in the region of the PAU. We also found a low value of time-averaged wall shear stress (1.24 N/m2) and a high value of the temporal oscillation in the wall shear stress (oscillatory shear index = 0.13) in the region of the PAU. After endovascular treatment, these haemodynamic parameters were distributed uniformly on the luminal surface of the stent graft. These findings suggest that wall shear stress could be considered one of the major haemodynamic factors indicating the structural fragility of the PAU wall, which ultimately lead to PAU growth and rupture. PMID:23736658

  12. Decreased haemodynamic response and decoupling of cortical gamma-band activity and tissue oxygen perfusion after striatal interleukin-1 injection.

    PubMed

    Bray, Natasha; Burrows, Fiona E; Jones, Myles; Berwick, Jason; Allan, Stuart M; Schiessl, Ingo

    2016-08-24

    Neurovascular coupling describes the mechanism by which the energy and oxygen demand arising from neuronal activity is met by an increase in regional blood flow, known as the haemodynamic response. Interleukin 1 (IL-1) is a pro-inflammatory cytokine and an important mediator of neuronal injury, though mechanisms through which IL-1 exerts its effects in the brain are not fully understood. In this study, we set out to investigate if increased cerebral levels of IL-1 have a negative effect on the neurovascular coupling in the cortex in response to sensory stimulation. We used two approaches to measure the neuronal activity and haemodynamic changes in the anaesthetised rat barrel somatosensory cortex in response to mechanical whisker stimulation, before and for 6 h after intra-striatal injection of interleukin-1β or vehicle. First, we used two-dimensional optical imaging spectroscopy (2D-OIS) to measure the size of the functional haemodynamic response, indicated by changes of oxyhaemoglobin (HbO2) and total haemoglobin (HbT) concentration. In the same animals, immunostaining of immunoglobulin G and SJC-positive extravasated neutrophils was used to confirm the pro-inflammatory effects of interleukin-1β (IL-1β). Second, to examine the functional coupling between neuronal activity and the haemodynamic response, we used a 'Clark-style' electrode combined with a single sharp electrode to simultaneously record local tissue oxygenation (partial pressure oxygen, pO2) in layer IV/V of the stimulated barrel cortex and multi-unit activity (MUA) together with local field potentials (LFPs), respectively. 2D-OIS data revealed that the size of the haemodynamic response to mechanical whisker stimulation declined over the 6 h following IL-1β injection whereas the vehicle group remained stable, significant differences being seen after 5 h. Moreover, the size of the transient increases of neuronal LFP activity in response to whisker stimulation decreased after IL-1β injection

  13. Haemodynamic changes in hepatocellular carcinoma and liver parenchyma under balloon occlusion of the hepatic artery.

    PubMed

    Sugihara, Fumie; Murata, Satoru; Ueda, Tatsuo; Yasui, Daisuke; Yamaguchi, Hidenori; Miki, Izumi; Kawamoto, Chiaki; Uchida, Eiji; Kumita, Shin-Ichiro

    2017-06-01

    To investigate haemodynamic changes in hepatocellular carcinoma (HCC) and liver under hepatic artery occlusion. Thirty-eight HCC nodules in 25 patients were included. Computed tomography (CT) during hepatic arteriography (CTHA) with and without balloon occlusion of the hepatic artery was performed. CT attenuation and enhancement volume of HCC and liver with and without balloon occlusion were measured on CTHA. Influence of balloon position (segmental or subsegmental branch) was evaluated based on differences in HCC-to-liver attenuation ratio (H/L ratio) and enhancement volume of HCC and liver. In the segmental group (n = 20), H/L ratio and enhancement volume of HCC and liver were significantly lower with balloon occlusion than without balloon occlusion. However, in the subsegmental group (n = 18), H/L ratio was significantly higher and liver enhancement volume was significantly lower with balloon occlusion; HCC enhancement volume was similar with and without balloon occlusion. Rate of change in H/L ratio and enhancement volume of HCC and liver were lower in the segmental group than in the subsegmental group. There were significantly more perfusion defects in HCC in the segmental group. Hepatic artery occlusion causes haemodynamic changes in HCC and liver, especially with segmental occlusion. • Hepatic artery occlusion causes haemodynamic changes in hepatocellular carcinoma and liver. • Segmental occlusion decreased rate of change in hepatocellular carcinoma-to-liver attenuation ratio. • Subsegmental occlusion increased rate of change in hepatocellular carcinoma-to-liver attenuation ratio. • Hepatic artery occlusion decreased enhancement volume of hepatocellular carcinoma and liver. • Hepatic artery occlusion causes perfusion defects in hepatocellular carcinoma.

  14. Influence of different computational approaches for stent deployment on cerebral aneurysm haemodynamics

    PubMed Central

    Bernardini, Annarita; Larrabide, Ignacio; Morales, Hernán G.; Pennati, Giancarlo; Petrini, Lorenza; Cito, Salvatore; Frangi, Alejandro F.

    2011-01-01

    Cerebral aneurysms are abnormal focal dilatations of artery walls. The interest in virtual tools to help clinicians to value the effectiveness of different procedures for cerebral aneurysm treatment is constantly growing. This study is focused on the analysis of the influence of different stent deployment approaches on intra-aneurysmal haemodynamics using computational fluid dynamics (CFD). A self-expanding stent was deployed in an idealized aneurysmatic cerebral vessel in two initial positions. Different cases characterized by a progression of simplifications on stent modelling (geometry and material) and vessel material properties were set up, using finite element and fast virtual stenting methods. Then, CFD analysis was performed for untreated and stented vessels. Haemodynamic parameters were analysed qualitatively and quantitatively, comparing the cases and the two initial positions. All the cases predicted a reduction of average wall shear stress and average velocity of almost 50 per cent after stent deployment for both initial positions. Results highlighted that, although some differences in calculated parameters existed across the cases based on the modelling simplifications, all the approaches described the most important effects on intra-aneurysmal haemodynamics. Hence, simpler and faster modelling approaches could be included in clinical workflow and, despite the adopted simplifications, support clinicians in the treatment planning. PMID:22670204

  15. Effect of intravenous infusion of dexmedetomidine on perioperative haemodynamic changes and postoperative recovery: A study with entropy analysis.

    PubMed

    Patel, Chirag Ramanlal; Engineer, Smita R; Shah, Bharat J; Madhu, S

    2012-11-01

    Dexmedetomidine, an α2 agonist, when used as an adjuvant in general anaesthesia attenuates stress response to various noxious stimuli, maintains perioperative haemodynamic stability and provides sedation without significant respiratory depression postoperatively. Sixty patients were randomly divided into two groups of 30 each. In group A, fentanyl 2 μg/kg and in group B dexmedetomidine were given intravenously as loading dose of 1 μg/kg over 10 min prior to induction. After induction with thiopentone, in group B, dexmedetomidine was given as infusion at a dose of 0.2-0.8 μg/kg. Sevoflurane was used as inhalation agent in both groups. Haemodynamic variables and entropy (response entropy and state entropy) were recorded continuously. Postoperative sedation and recovery were assessed by sedation score and modified Aldrete's score, respectively. Dexmedetomidine significantly attenuates stress response at intubation with lesser increase in heart rate (10% vs. 17%), systolic blood pressure (6% vs. 23%) and diastolic blood pressure (7% vs. 20%) as compared to the control group (P<0.05). Intraoperatively, an average of 8% fall in systolic blood pressure and 8.16% fall in diastolic pressure in the test group as compared to 3.6% rise in systolic and 3.3% in diastolic pressure of the control group was observed. Postoperatively, the test group showed significant sedation at 2 h as compared to the control group (P=0.00) and recovery was better in the control group for the first 2 h post extubation. Dexmedetomidine attenuates various stress responses during surgery and maintains the haemodynamic stability when used as an adjuvant in general anaesthesia. Also, the sedative action of dexmedetomidine delays recovery for the first few hours post extubation.

  16. Evaluating the roles of detailed endocardial structures on right ventricular haemodynamics by means of CFD simulations.

    PubMed

    Sacco, Federica; Paun, Bruno; Lehmkuhl, Oriol; Iles, Tinen L; Iaizzo, Paul A; Houzeaux, Guillaume; Vázquez, Mariano; Butakoff, Constantine; Aguado-Sierra, Jazmin

    2018-06-11

    Computational modelling plays an important role in right ventricular (RV) haemodynamic analysis. However, current approaches employ smoothed ventricular anatomies. The aim of this study is to characterise RV haemodynamics including detailed endocardial structures like trabeculae, moderator band and papillary muscles (PMs). Four paired detailed and smoothed RV endocardium models (two male and two female) were reconstructed from ex-vivo human hearts high-resolution magnetic resonance images (MRI). Detailed models include structures with ≥1 mm 2 cross-sectional area. Haemodynamic characterisation was done by computational fluid dynamics (CFD) simulations with steady and transient inflows, using high performance computing (HPC). The differences between the flows in smoothed and detailed models were assessed using Q-criterion for vorticity quantification, the pressure drop between inlet and outlet, and the wall shear stress (WSS). Results demonstrated that detailed endocardial structures increase the degree of intra-ventricular pressure drop, decrease the WSS and disrupt the dominant vortex creating secondary small vortices. Increasingly turbulent blood flow was observed in the detailed RVs. Female RVs were less trabeculated and presented lower pressure drops than the males. In conclusion, neglecting endocardial structures in RV haemodynamic models may lead to inaccurate conclusions about the pressures, stresses, and blood flow behaviour in the cavity. This article is protected by copyright. All rights reserved.

  17. Haemodynamic responses and changes of haemostatic risk factors in cold-adapted humans.

    PubMed

    De Lorenzo, F; Kadziola, Z; Mukherjee, M; Saba, N; Kakkar, V V

    1999-09-01

    Epidemiological studies have shown an increase in acute myocardial infarctions or deaths due to myocardial infarction in colder weather; the mechanisms most likely involve increased blood levels of haemostatic risk factors, and increases in arterial blood pressure and heart rate. We studied the relationship between cold adaptation, haemostatic risk factors and haemodynamic variables. Cold adaptation was obtained by a programme of immersion of the whole body up to the neck in a water-filled bath, the temperature of which was gradually decreased from 22 degrees C to 14 degrees C, time of exposure being increased from 5 to 20 min over a period of 90 days. We studied 428 patients (44% men) and measured blood levels of fibrinogen, plasminogen activator inhibitor 1 (PAI-1), tissue plasminogen activator antigen (t-PA), plasma viscosity, von Willebrand factor, D-dimer and platelet count, both at baseline and after 90 days of daily immersion. There were significant reductions in von Willebrand factor (-3%; p < 0.001), and plasma viscosity (-3.0 s; p < 0.001), and a mild but significant increase in PAI-1 (+0.3 IU/ml; p = 0.02). The pressure rate product (systolic blood pressure x heart rate) was also significantly lower after cold adaptation (-310; p = 0.004). Cold adaptation, compared with exposure to cold weather, induces different haemodynamic responses and changes of blood levels of haemostatic risk factors.

  18. Does extubation result in haemodynamic instability in patients following coronary artery bypass grafts?

    PubMed

    Walthall, H; Ray, S; Robson, D

    2001-10-01

    Coronary heart disease and its management continue to be at the centre of Government health policy. The present political climate demands clinical effectiveness and best practice should be established, while maintaining the philosophy of cost-effectiveness and resource management. These directives have led practitioners to question the care of patients following coronary artery bypass surgery, in particular the role of mechanical ventilation and the subsequent act of extubation. A retrospective study of 89 patients who had coronary artery bypass grafts (emergency and elective) was undertaken, to establish if extubation had a significant effect on the haemodynamic status of patients with variable degrees of left ventricular function (19% with poor left ventricular function). The study found that extubation was achieved within a mean time of 4.97 hours following return from surgery. Extubation resulted in a significant increase in heart rate (P = 0.001), as well as a respiratory acidosis (pCO2: P = 0.000; pH: P = 0.000). However, the stability of the patient was not compromised, with neither mean arterial blood pressure (P = 0.825) nor oxygenation levels (P = 0.267) being significantly altered by extubation. On multivariate analysis, the act of extubation had no significant effect on any of the dependent variables. These results suggest that it is not extubation alone that has an impact on the haemodynamic stability of patients following coronary artery bypass grafts, but that this is indeed multifactorial. Therefore extubation is 'safe' practice for patients with varying degrees of left ventricular function following coronary artery bypass grafts. Limitations of the study are acknowledged.

  19. Facing emotions in narcolepsy with cataplexy: haemodynamic and behavioural responses during emotional stimulation.

    PubMed

    de Zambotti, Massimiliano; Pizza, Fabio; Covassin, Naima; Vandi, Stefano; Cellini, Nicola; Stegagno, Luciano; Plazzi, Giuseppe

    2014-08-01

    Narcolepsy with cataplexy is a complex sleep disorder that affects the modulation of emotions: cataplexy, the key symptom of narcolepsy, is indeed strongly linked with emotions that usually trigger the episodes. Our study aimed to investigate haemodynamic and behavioural responses during emotional stimulation in narco-cataplexy. Twelve adult drug-naive narcoleptic patients (five males; age: 33.3 ± 9.4 years) and 12 healthy controls (five males; age: 30.9 ± 9.5 years) were exposed to emotional stimuli (pleasant, unpleasant and neutral pictures). Heart rate, arterial blood pressure and mean cerebral blood flow velocity of the middle cerebral arteries were continuously recorded using photoplethysmography and Doppler ultrasound. Ratings of valence and arousal and coping strategies were scored by the Self-Assessment Manikin and by questionnaires, respectively. Narcoleptic patients' haemodynamic responses to pictures overlapped with the data obtained from controls: decrease of heart rate and increase of mean cerebral blood flow velocity regardless of pictures' content, increase of systolic blood pressure during the pleasant condition, and relative reduction of heart rate during pleasant and unpleasant conditions. However, when compared with controls, narcoleptic patients reported lower arousal scores during the pleasant and neutral stimulation, and lower valence scores during the pleasant condition, respectively, and also a lower score at the 'focus on and venting of emotions' dimensions of coping. Our results suggested that adult narcoleptic patients, compared with healthy controls, inhibited their emotion-expressive behaviour to emotional stimulation, and that may be related to the development of adaptive cognitive strategies to face emotions avoiding cataplexy. © 2014 European Sleep Research Society.

  20. Freedom Solo® versus Trifecta® bioprostheses: clinical and haemodynamic evaluation after propensity score matching.

    PubMed

    Cerqueira, Rui J; Raimundo, Renata; Moreira, Soraia; Saraiva, Francisca A; Andrade, Marta; Salgueiro, Elson; Almeida, Jorge; Amorim, Mário Jorge; Pinho, Paulo; Lourenço, André P; Leite-Moreira, Adelino

    2018-01-16

    The goal of this study was to compare the stentless Freedom Solo® (FS) and the stented Trifecta® (TF) aortic bioprostheses with regard to haemodynamic profile, left ventricular mass regression and early and late postoperative outcomes and survival. A longitudinal cohort study of consecutive patients undergoing aortic valve replacement (2009-16) with either the FS or TF at 1 centre was performed. Local databases and national records were queried. Prosthesis haemodynamics and left ventricular dimensions were obtained from postoperative echocardiograms. After propensity score matching (21 covariates), the Kaplan-Meier and competing risk analyses were performed for survival and the combined outcome of structural valve deterioration and endocarditis, respectively. Haemodynamics and mass regression were assessed by a mixed-effects model including propensity score as a covariate. From a total sample of 397 patients with the FS and 525 TF bioprostheses with a median follow-up time of 4.0 (2.2-6.0) and 2.4 (1.4-3.7) years, respectively, a matched sample of 329 pairs was obtained. Matched groups showed no differences in survival (hazard ratio = 1.04, 95% confidence interval = 0.69-1.56) or cumulative hazards of combined outcome (subdistribution hazard ratio = 0.54, 95% confidence interval = 0.21-1.39). Although the TF showed an improved haemodynamic profile, no difference was found in mass regression. Patients with TF bioprostheses had higher rates of prolonged mechanical ventilation, whereas patients with the FS bioprosthesis showed higher rates of thrombocytopenia. The TF showed an improved haemodynamic profile compared to the FS, but this did not translate into further reverse remodelling. Postoperative outcomes and survival rates were comparable for both bioprostheses. Long-term follow-up is needed for comparisons with classical bioprosthesis models. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for

  1. Mesenchymal stem cells correct haemodynamic dysfunction associated with liver injury after extended resection in a pig model.

    PubMed

    Tautenhahn, Hans-Michael; Brückner, Sandra; Uder, Christiane; Erler, Silvio; Hempel, Madlen; von Bergen, Martin; Brach, Janine; Winkler, Sandra; Pankow, Franziska; Gittel, Claudia; Baunack, Manja; Lange, Undine; Broschewitz, Johannes; Dollinger, Matthias; Bartels, Michael; Pietsch, Uta; Amann, Kerstin; Christ, Bruno

    2017-06-01

    In patients, acute kidney injury (AKI) is often due to haemodynamic impairment associated with hepatic decompensation following extended liver surgery. Mesenchymal stem cells (MSCs) supported tissue protection in a variety of acute and chronic diseases, and might hence ameliorate AKI induced by extended liver resection. Here, 70% liver resection was performed in male pigs. MSCs were infused through a central venous catheter and haemodynamic parameters as well as markers of acute kidney damage were monitored under intensive care conditions for 24 h post-surgery. Cytokine profiles were established to anticipate the MSCs' potential mode of action. After extended liver resection, hyperdynamic circulation, associated with hyponatraemia, hyperkalaemia, an increase in serum aldosterone and low urine production developed. These signs of hepatorenal dysfunction and haemodynamic impairment were corrected by MSC treatment. MSCs elevated PDGF levels in the serum, possibly contributing to circulatory homeostasis. Another 14 cytokines were increased in the kidney, most of which are known to support tissue regeneration. In conclusion, MSCs supported kidney and liver function after extended liver resection. They probably acted through paracrine mechanisms improving haemodynamics and tissue homeostasis. They might thus provide a promising strategy to prevent acute kidney injury in the context of post-surgery acute liver failure.

  2. Effect of intravenous infusion of dexmedetomidine on perioperative haemodynamic changes and postoperative recovery: A study with entropy analysis

    PubMed Central

    Patel, Chirag Ramanlal; Engineer, Smita R; Shah, Bharat J; Madhu, S

    2012-01-01

    Background: Dexmedetomidine, an α2 agonist, when used as an adjuvant in general anaesthesia attenuates stress response to various noxious stimuli, maintains perioperative haemodynamic stability and provides sedation without significant respiratory depression postoperatively. Methods: Sixty patients were randomly divided into two groups of 30 each. In group A, fentanyl 2 μg/kg and in group B dexmedetomidine were given intravenously as loading dose of 1 μg/kg over 10 min prior to induction. After induction with thiopentone, in group B, dexmedetomidine was given as infusion at a dose of 0.2–0.8 μg/kg. Sevoflurane was used as inhalation agent in both groups. Haemodynamic variables and entropy (response entropy and state entropy) were recorded continuously. Postoperative sedation and recovery were assessed by sedation score and modified Aldrete's score, respectively. Results: Dexmedetomidine significantly attenuates stress response at intubation with lesser increase in heart rate (10% vs. 17%), systolic blood pressure (6% vs. 23%) and diastolic blood pressure (7% vs. 20%) as compared to the control group (P<0.05). Intraoperatively, an average of 8% fall in systolic blood pressure and 8.16% fall in diastolic pressure in the test group as compared to 3.6% rise in systolic and 3.3% in diastolic pressure of the control group was observed. Postoperatively, the test group showed significant sedation at 2 h as compared to the control group (P=0.00) and recovery was better in the control group for the first 2 h post extubation. Conclusion: Dexmedetomidine attenuates various stress responses during surgery and maintains the haemodynamic stability when used as an adjuvant in general anaesthesia. Also, the sedative action of dexmedetomidine delays recovery for the first few hours post extubation. PMID:23325938

  3. Investigating the influence of haemodynamic stimuli on intracranial aneurysm inception.

    PubMed

    Chen, Haoyu; Selimovic, Alisa; Thompson, Harry; Chiarini, Alessandro; Penrose, Justin; Ventikos, Yiannis; Watton, Paul N

    2013-07-01

    We propose a novel method to reconstruct the hypothetical geometry of the healthy vasculature prior to intracranial aneurysm (IA) formation: a Frenet frame is calculated along the skeletonization of the arterial geometry; upstream and downstream boundaries of the aneurysmal segment are expressed in terms of the local Frenet frame basis vectors; the hypothetical healthy geometry is then reconstructed by propagating a closed curve along the skeleton using the local Frenet frames so that the upstream boundary is smoothly morphed into the downstream boundary. This methodology takes into account the tortuosity of the arterial vasculature and requires minimal user subjectivity. The method is applied to 22 clinical cases depicting IAs. Computational fluid dynamic simulations of the vasculature without IA are performed and the haemodynamic stimuli in the location of IA formation are examined. We observe that locally elevated wall shear stress (WSS) and gradient oscillatory number (GON) are highly correlated (20/22 for WSS and 19/22 for GON) with regions susceptible to sidewall IA formation whilst haemodynamic indices associated with the oscillation of the WSS vectors have much lower correlations.

  4. Relative myotoxic and haemodynamic effects of the beta-agonists fenoterol and clenbuterol measured in conscious unrestrained rats.

    PubMed

    Burniston, Jatin G; Tan, Lip-Bun; Goldspink, David F

    2006-11-01

    The beta(2)-adrenoceptor (beta(2)-AR) agonists clenbuterol and fenoterol have similar beneficial effects in animal models of heart failure. However, large doses of clenbuterol can induce cardiomyocyte death, and it is not known which of these agents has the most favourable therapeutic profile. We have investigated the cardiotoxicity of clenbuterol and fenoterol alongside that of isoprenaline, and compared their haemodynamic effects. Wistar rats (n = 6 per group) were subcutaneously injected with each beta-agonist (0.003-3 mmol kg(-1)) or saline, and cardiomyocyte apoptosis was detected by caspase 3 immunohistochemistry. In a separate experiment, rats (n = 4) were given equivalent doses to those used in the myotoxicity studies, in a randomized cross-over design, and their blood pressure recorded via radiotelemetry. Injection of 0.3 mmol kg(-1) fenoterol or isoprenaline, but not clenbuterol, induced significant cardiomyocyte apoptosis (0.4 +/- 0.05%; P < 0.05). At 3 mmol kg(-1), all agonists induced apoptosis (fenoterol, 1.1 +/- 0.1%; isoprenaline, 0.9 +/- 0.8%; and clenbuterol, 0.4 +/- 0.07%; P < 0.05). beta(1)-Adrenoceptor antagonism (10 mg kg(-1) bisoprolol) prevented 92% (P < 0.05) of apoptosis induced by all three agonists, but clenbuterol-induced apoptosis could also be prevented by 96% (P < 0.05) by beta(2)-AR antagonism (10 mg kg(-1) ICI 118 551). Clenbuterol decreased diastolic (1.3- to 1.6-fold; P < 0.05) and systolic blood pressure (1.3-fold; P < 0.05), and doses > 0.3 mmol kg(-1) increased heart rate (1.4-fold; P < 0.05). Fenoterol increased heart rate (1.2- to 1.4-fold; P < 0.05), and doses > 0.3 mmol kg(-1) decreased diastolic blood pressure (1.3-fold; P < 0.05). In conclusion, the cardiotoxicity of fenoterol was similar to isoprenaline and greater than clenbuterol, and fenoterol had less desirable haemodynamic effects.

  5. Effect of a physical activity programme in the aquatic environment on haemodynamic constants in pregnant women.

    PubMed

    Vázquez-Lara, Juana María; Ruiz-Frutos, Carlos; Rodríguez-Díaz, Luciano; Ramírez-Rodrigo, Jesús; Villaverde-Gutiérrez, Carmen; Torres-Luque, Gema

    2017-09-20

    To evaluate the effect of a physical activity programme in the aquatic environment with immersion up to the neck, of six weeks duration, on haemodynamic constants in pregnant women. A six-week physical activity programme in the aquatic environment was carried out with a total of 46 pregnant women, who were distributed into an experimental group (n = 18), which participated in the programme, and a control group (n = 28), which followed routine care. In both groups different haemodynamic measurements were evaluated before and after the program. At the beginning of the programme the mean systolic blood pressure was similar between groups, but diastolic blood pressure was slightly higher in the experimental group. When the measurements at the last session were compared, arterial pressures (systolic, diastolic and mean) were significantly higher in the control group (p <.050). Similarly, the initial plasma volume values did not differ between groups, but after the intervention, the control group women showed a higher mean (p <.010). The fraction of sodium excretion (FENa) increased significantly in the experimental group, after the programme, with a mean three times higher (p <.050). Aldosterone plasma levels did not show significant differences between the groups in the different measurements. A programme of swimming and immersion exercises in pregnant women contributes to hydrosaline balance, preventing an excessive increase in usual plasma volume during pregnancy and in the activity of the renin-aldosterone axis. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  6. [The relationship between ophthalmic nerve lesion in glaucoma and ocular and systemic haemodynamic disturbance].

    PubMed

    Liu, L; Yuan, S; Yang, W

    1999-04-01

    To explore the relationship between the optic nerve lesion in glaucoma and ocular and systemic haemodynamic disturbance. The color Doppler imaging was used to study blood velocity in the ophthalmic, the central retinal and the short posterior ciliary arteries in 34 patients with primary open angle glaucoma, 31 patients with low tension glaucoma and 90 healthy controls. The peak systolic velocity(PSV), the end diastolic velocity (EDV) and resistive index (RI) in each artery were measured, moreover the nailfold microcirculation and blood viscosity in each patient were examined. Compared with the control group, the PSV and EDV of the central retinal arteries were significantly lower while the RI of the central retinal arteries was significantly higher in both POAG and LTG patients. The RI of the short posterior ciliary arteries however was significantly higher in POAG. Nailfold microcirculation shows that some important parameters, including flow pattern, loop surrounding, morphological weighted value, total weighted value and capillary deformity rate in the two glaucoma groups were higher, whereas the flow velocity was lower than in the control group. The plasm viscosity and the whole blood viscosity (low spear) were higher than normal. According to our measurements, the nailfold microcirculation and blood viscosity was worse at the end stage of glaucoma than at early stage. The correlative analysis between measurement results of color doppler imaging and microcirculation and heamorrheology showed that nailfold microcirculation morphological weighted value was negatively correlated with the EDV of the central retinal artery and positively correlated with the RI of the central retinal artery in LTG patients. The abnormity of ocular haemodynamics and systemic microcirculation and blood viscosity is one important factor of optic nerve damage in glaucoma.

  7. Mapping cortical haemodynamics during neonatal seizures using diffuse optical tomography: A case study

    PubMed Central

    Singh, Harsimrat; Cooper, Robert J.; Wai Lee, Chuen; Dempsey, Laura; Edwards, Andrea; Brigadoi, Sabrina; Airantzis, Dimitrios; Everdell, Nick; Michell, Andrew; Holder, David; Hebden, Jeremy C.; Austin, Topun

    2014-01-01

    Seizures in the newborn brain represent a major challenge to neonatal medicine. Neonatal seizures are poorly classified, under-diagnosed, difficult to treat and are associated with poor neurodevelopmental outcome. Video-EEG is the current gold-standard approach for seizure detection and monitoring. Interpreting neonatal EEG requires expertise and the impact of seizures on the developing brain remains poorly understood. In this case study we present the first ever images of the haemodynamic impact of seizures on the human infant brain, obtained using simultaneous diffuse optical tomography (DOT) and video-EEG with whole-scalp coverage. Seven discrete periods of ictal electrographic activity were observed during a 60 minute recording of an infant with hypoxic–ischaemic encephalopathy. The resulting DOT images show a remarkably consistent, high-amplitude, biphasic pattern of changes in cortical blood volume and oxygenation in response to each electrographic event. While there is spatial variation across the cortex, the dominant haemodynamic response to seizure activity consists of an initial increase in cortical blood volume prior to a large and extended decrease typically lasting several minutes. This case study demonstrates the wealth of physiologically and clinically relevant information that DOT–EEG techniques can yield. The consistency and scale of the haemodynamic responses observed here also suggest that DOT–EEG has the potential to provide improved detection of neonatal seizures. PMID:25161892

  8. A Systematic Review and Meta-Analysis of the Haemodynamic Effects of Cannabidiol

    PubMed Central

    Sultan, Salahaden R.; Millar, Sophie A.; England, Timothy J.; O'Sullivan, Saoirse E.

    2017-01-01

    Despite cannabidiol (CBD) having numerous cardiovascular effects in vitro, its haemodynamic effects in vivo are unclear. Nonetheless, the clinical use of CBD (Epidiolex) is becoming more widespread. The aim of this systematic review was to establish whether CBD is associated with changes in haemodynamics in vivo. Twenty-five studies that assessed the haemodynamic effects of CBD (from PubMed, Medline and EMBASE) were systematically reviewed and meta-analyzed. Data on blood pressure (BP), heart rate (HR), and blood flow (BF) were extracted and analyzed using random effects models. Twenty-two publications assessed BP and HR among 6 species (BP n = 344 and HR n = 395), and 5 publications assessed BF in 3 species (n = 56) after acute dosing of CBD. Chronic dosing was assessed in 4 publications in 3 species (total subjects BP, n = 6; HR, n = 27; BF, n = 3). Acute CBD dosing had no effect on BP or HR under control conditions. Similarly, chronic dosing with CBD had no effect on HR. In models of stress, acute CBD administration significantly reduced the increase in BP and HR induced by stress (BP, mean difference (MD) −3.54, 95% CI −5.19, −1.9, p < 0.0001; HR, MD −16.23, 95% CI −26.44, −6.02, p = 0.002). In mouse models of stroke, CBD significantly increased cerebral blood flow (CBF, standardized mean difference (SMD) 1.62, 95% CI 0.41, 2.83, p = 0.009). Heterogeneity among the studies was present, there was no publication bias except in HR of control and stressful conditions after acute CBD dosing, and median study quality was 5 out of 9 (ranging from 1 to 8). From the limited data available, we conclude that acute and chronic administration of CBD had no effect on BP or HR under control conditions, but reduces BP and HR in stressful conditions, and increases cerebral blood flow (CBF) in mouse models of stroke. Further studies are required to fully understand the potential haemodynamic effects of CBD in humans under normal and pathological conditions. PMID

  9. A comparison of head motion and prefrontal haemodynamics during upright and recumbent cycling exercise.

    PubMed

    Tempest, Gavin D; Eston, Roger G; Parfitt, Gaynor

    2017-11-01

    The aim of this observational study was to compare head motion and prefrontal haemodynamics during exercise using three commercial cycling ergometers. Participants (n = 12) completed an incremental exercise test to exhaustion during upright, recumbent and semi-recumbent cycling. Head motion (using accelerometry), physiological data (oxygen uptake, end-tidal carbon dioxide [P ET CO 2 ] and heart rate) and changes in prefrontal haemodynamics (oxygenation, deoxygenation and blood volume using near infrared spectroscopy [NIRS]) were recorded. Despite no difference in oxygen uptake and heart rate, head motion was higher and P ET CO 2 was lower during upright cycling at maximal exercise (P<0·05). Analyses of covariance (covariates: head motion P>0·05; P ET CO 2 , P<0·01) revealed that prefrontal oxygenation was higher during semi-recumbent than recumbent cycling and deoxygenation and blood volume were higher during upright than recumbent and semi-recumbent cycling (respectively; P<0·05). This work highlights the robustness of the utility of NIRS to head motion and describes the potential postural effects upon the prefrontal haemodynamic response during upright and recumbent cycling exercise. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  10. Effects of nitric oxide synthase inhibition with or without cyclooxygenase-2 inhibition on resting haemodynamics and responses to exendin-4

    PubMed Central

    Gardiner, S M; March, J E; Kemp, P A; Bennett, T

    2006-01-01

    Background and purpose: Interactions between the NO system and the cyclooxygenase systems may be important in cardiovascular regulation. Here we measured the effects of acute cyclooxygenase-2 inhibition (with parecoxib), alone and in combination with NOS inhibition (with N G-nitro-L-arginine methyl ester (L-NAME)), on resting cardiovascular variables and on responses to the glucagon-like peptide 1 agonist, exendin-4, which causes regionally-selective vasoconstriction and vasodilatation. Experimental approach: Rats were instrumented with flow probes and intravascular catheters to measure regional haemodynamics in the conscious, freely moving state. L-NAME was administered as a primed infusion 180 min after administration of parecoxib or vehicle, and exendin-4 was given 60 min after the onset of L-NAME infusion. Key results: Parecoxib had no effect on resting cardiovascular variables or on responses to L-NAME. Exendin-4 caused a pressor response accompanied by tachycardia, mesenteric vasoconstriction and hindquarters vasodilatation. Parecoxib did not affect haemodynamic responses to exendin-4, but L-NAME inhibited its hindquarters vasodilator and tachycardic effects. When combined, L-NAME and parecoxib almost abolished the hindquarters vasodilatation while enhancing the pressor response. Conclusions and implications: Cyclooxygenase-2-derived products do not affect basal haemodynamic status in conscious normotensive rats, or influence the NO system acutely. The inhibitory effects of L-NAME on the hindquarters vasodilator and tachycardic effects of exendin-4 are consistent with a previous study that showed those events to be β-adrenoceptor mediated. The additional effect of parecoxib on responses to exendin-4 in the presence of L-NAME, is consistent with other evidence for enhanced involvement of vasodilator prostanoids when NO production is reduced. PMID:17016494

  11. Perioperative goal-directed haemodynamic therapy based on flow parameters: a concept in evolution.

    PubMed

    Meng, L; Heerdt, P M

    2016-12-01

    Haemodynamic management incorporating direct or surrogate stroke volume monitoring has experienced a rapid evolution, because of emergence of the "goal-directed therapy" concept and technological developments aimed at providing a parameter leading to the goal. Nonetheless, consensus on both definitions of the ideal "goal" and strategies for achieving it remain elusive. For this review, we first consider basic physiological and patient monitoring factors relevant to the concept of "fluid responsiveness", and then focus upon randomized controlled trials and meta-analyses involving goal-directed haemodynamic therapy based on various flow parameters. Finally, we discuss the current status of noninvasive methods for monitoring fluid responsiveness. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. The haemodynamic effects of bolus versus slower infusion of intravenous crystalloid in healthy volunteers.

    PubMed

    Ukor, Ida F; Hilton, Andrew K; Bailey, Michael J; Bellomo, Rinaldo

    2017-10-01

    This pilot study aimed to characterise the haemodynamic effect of 1L of IV normal saline (NS) administered as a rapid versus slow infusion on cardiac output (CO), heart rate (HR), systemic blood pressures, and carotid blood flow in six healthy volunteers. Six healthy male volunteers aged 18-65years were randomized to receive 1L NS given over 30min or 120min. On a subsequent study session the alternate fluid regimen was administered. Haemodynamic data was gathered using a non-invasive finger arterial pressure monitor (Nexfin®), echocardiography and carotid duplex sonography. Time to micturition and urine volume was also assessed. Compared to baseline, rapid infusion of 1L of saline over 30min produced a fall in Nexfin®-measured CO by 0.62L/min (p<0.001), whereas there was a marginal but significant increase during infusion of 1L NS over 120min of 0.02L/min (p<0.001). This effect was mirrored by changes in HR and blood pressure (BP) (p<0.001). There were no significant changes in carotid blood flow, time to micturition, or urine volume produced. Slower infusion of 1L NS in healthy male volunteers produced a greater increase in CO, HR and BP than rapid infusion. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  13. Human haemodynamic frequency harmonics regulate the inflammatory phenotype of vascular endothelial cells.

    PubMed

    Feaver, Ryan E; Gelfand, Bradley D; Blackman, Brett R

    2013-01-01

    Haemodynamic variations are inherent to blood vessel geometries (such as bifurcations) and correlate with regional development of inflammation and atherosclerosis. However, the complex frequency spectrum characteristics from these haemodynamics have never been exploited to test whether frequency variations are critical determinants of endothelial inflammatory phenotype. Here we utilize an experimental Fourier transform analysis to systematically manipulate individual frequency harmonics from human carotid shear stress waveforms applied in vitro to human endothelial cells. The frequency spectrum, specifically the 0 th and 1st harmonics, is a significant regulator of inflammation, including NF-κB activity and downstream inflammatory phenotype. Further, a harmonic-based regression-model predicts eccentric NF-κB activity observed in the human internal carotid artery. Finally, short interfering RNA-knockdown of the mechanosensor PECAM-1 reverses frequency-dependent regulation of NF-κB activity. Thus, PECAM-1 may have a critical role in the endothelium's exquisite sensitivity to complex shear stress frequency harmonics and provide a mechanism for the focal development of vascular inflammation.

  14. Transcatheter aortic valve implantation of a second-generation valve for pure aortic regurgitation: procedural outcome, haemodynamic data and follow-up.

    PubMed

    Schlingloff, Friederike; Schäfer, Ulrich; Frerker, Christian; Schmoeckel, Michael; Bader, Ralf

    2014-09-01

    The second-generation Jenavalve prosthesis (Jenavalve Technology, Inc., Munich, Germany) is the first transcatheter valve Conformité Européene (CE) marked for treatment of both aortic stenosis (AS) and pure aortic regurgitation (AR). Although the feasibility of the Jenavalve transcatheter aortic valve implantation (TAVI) in patients with pure AR has been described, haemodynamic and follow-up data are lacking. We report on a series of 10 transapical Jenavalve implantations for pure AR between December 2012 and September 2013. The patients were determined for TAVI by heart team decision at high surgical risk [log EuroSCORE (European System for Cardiac Operative Risk Evaluation) >20%], frailty or Charlson Comorbidity Index (CCI). Transaortic gradients and right heart haemodynamics were measured invasively before and after TAVI. Ventriculography and transoesophageal echocardiography were used to determine paravalvular regurgitation. All-cause mortality, NYHA functional class and echocardiographic measurements were followed up at 30 days and at 3, 9 and 12 months postoperatively. Overall, mean age was 79 ± 9 years, mean left ventricular ejection fraction 50 ± 17% and mean log EuroSCORE 28.3 ± 17.1%. There were no perioperative complications. Paravalvular regurgitation immediately after implantation was graded none (n = 6), trace (n = 3) or mild (n = 1). Overall 30-day mortality was 30% (3/10). Three patients refused further treatment, such as haemodialysis or treatment of mitral regurgitation. Rate for pacemaker implantation was 2/10 (20%). Intraprocedural success and haemodynamic data in our cases were good. The mortality in our group highlighted the importance of careful patient selection, especially for this pathology. The Jenavalve prosthesis proved to be suitable for treatment of AR in surgical high-risk patients. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. What is the normal haemodynamic response to passive leg raise? A study of healthy volunteers.

    PubMed

    Elwan, Mohammed H; Roshdy, Ashraf; Reynolds, Joseph A; Elsharkawy, Eman M; Eltahan, Salah M; Coats, Timothy J

    2018-05-04

    Passive leg raise (PLR) is used as self-fluid challenge to optimise fluid therapy by predicting preload responsiveness. However, there remains uncertainty around the normal haemodynamic response to PLR with resulting difficulties in application and interpretation in emergency care. We aim to define the haemodynamic responses to PLR in spontaneously breathing volunteers using a non-invasive cardiac output monitor, thoracic electrical bioimpedance, TEB (PLR-TEB). We recruited healthy volunteers aged 18 or above. Subjects were monitored using TEB in a semirecumbent position, followed by PLR for 3 min. The procedure was repeated after 6 min at the starting position. Correlation between the two PLRs was assessed using Spearman's r (r s ). Agreement between the two PLRs was evaluated using Cohen Kappa with responsiveness defined as ≥10% increase in stroke volume. Parametric and non-parametric tests were used as appropriate to evaluate statistical significance of baseline variables between responders and non-responders. We enrolled 50 volunteers, all haemodynamically stable at baseline, of whom 49 completed the study procedure. About half of our subjects were preload responsive. The ∆SV in the two PLRs was correlated (r s =0.68, 95% CI 0.49 to 0.8) with 85% positive concordance. Good agreement was observed with Cohen Kappa of 0.67 (95% CI 0.45 to 0.88). Responders were older and had significantly lower baseline stroke volume and cardiac output. Our results suggest that the PLR-TEB is a feasible method in spontaneously breathing volunteers with reasonable reproducibility. The age and baseline stroke volume effect suggests a more complex underlying physiology than commonly appreciated. The fact that half of the volunteers had a positive preload response, against the 10% threshold, leads to questions about how this measurement should be used in emergency care and will help shape future patient studies. © Article author(s) (or their employer(s) unless otherwise

  16. Relative myotoxic and haemodynamic effects of the β-agonists fenoterol and clenbuterol measured in conscious unrestrained rats

    PubMed Central

    Burniston, Jatin G; Tan, Lip-Bun; Goldspink, David F

    2007-01-01

    The β2-adrenoceptor (β2-AR) agonists clenbuterol and fenoterol have similar beneficial effects in animal models of heart failure. However, large doses of clenbuterol can induce cardiomyocyte death and it is not known which of these agents has the most favourable therapeutic profile. We have investigated the cardiotoxicity of clenbuterol and fenoterol alongside that of isoproterenol, and compared their haemodynamic effects. Wistar rats (n=6, per group) were subcutaneously injected with each β-agonist (0.003 mmol kg−1 to 3 mmol kg−1) or saline and cardiomyocyte apoptosis was detected by caspase 3 immunohistochemistry. In a separate experiment rats (n=4) were given equivalent doses to those used in the myotoxicity studies, in a randomised crossover design, and their blood pressure recorded via radio telemetry. Injection of 0.3 mmol kg−1 fenoterol or isoproterenol, but not clenbuterol, induced significant cardiomyocyte apoptosis (0.4±0.05%; P<0.05). At 3 mmol kg−1, all agonists induced apoptosis (fenoterol 1.1±0.1%; isoproterenol 0.9±0.8%; clenbuterol 0.4±0.07%; P<0.05). β1-AR antagonism (10 mg kg−1 bisoprolol) prevented (92%; P<0.05) apoptosis induced by all 3 agonists, but clenbuterol-induced apoptosis could also be prevented (96%; P<0.05) by β2-AR antagonism (10 mg kg−1 ICI118551). Clenbuterol decreased diastolic (1.3-1.6 fold; P<0.05) and systolic (1.3 fold; P<0.05) blood pressure and doses >0.3 mmol kg−1 increased heart rate (1.4 fold; P<0.05). Fenoterol increased heart rate (1.2-1.4 fold; P<0.05) and doses >0.3 mmol kg−1 decreased diastolic blood pressure (1.3 fold; P<0.05). In conclusion, the cardiotoxicity of fenoterol was similar to isoproterenol and greater than clenbuterol, and fenoterol had less desirable haemodynamic effects. PMID:16973691

  17. The predictive value of haemodynamic parameters for outcome of deep venous reconstructions in patients with chronic deep vein obstruction - A systematic review.

    PubMed

    Kurstjens, Rlm; de Wolf, Maf; Kleijnen, J; de Graaf, R; Wittens, Cha

    2017-09-01

    Objective The aim of this study was to investigate the predictive value of haemodynamic parameters on success of stenting or bypass surgery in patients with non-thrombotic or post-thrombotic deep venous obstruction. Methods EMBASE, MEDLINE and trial registries were searched up to 5 February 2016. Studies needed to investigate stenting or bypass surgery in patients with post-thrombotic obstruction or stenting for non-thrombotic iliac vein compression. Haemodynamic data needed to be available with prognostic analysis for success of treatment. Two authors, independently, selected studies and extracted data with risk bias assessment using the Quality in Prognosis Studies tool. Results Two studies using stenting and two using bypass surgery were included. Three investigated plethysmography, though results varied and confounding was not properly taken into account. Dorsal foot vein pressure and venous refill times appeared to be of influence in one study, though confounding by deep vein incompetence was likely. Another investigated femoral-central pressure gradients without finding statistical significance, though sample size was small without details on statistical methodology. Reduced femoral inflow was found to be a predictor for stent stenosis or occlusion in one study, though patients also received additional surgery to improve stent inflow. Data on prediction of haemodynamic parameters for stenting of non-thrombotic iliac vein compression were not available. Conclusions Data on the predictive value of haemodynamic parameters for success of treatment in deep venous obstructive disease are scant and of poor quality. Plethysmography does not seem to be of value in predicting outcome of stenting or bypass surgery in post-thrombotic disease. The relevance of pressure-related parameters is unclear. Reduced flow into the common femoral vein seems to be predictive for in-stent stenosis or occlusion. Further research into the predictive effect of haemodynamic parameters is

  18. Reproducibility of haemodynamical simulations in a subject-specific stented aneurysm model--a report on the Virtual Intracranial Stenting Challenge 2007.

    PubMed

    Radaelli, A G; Augsburger, L; Cebral, J R; Ohta, M; Rüfenacht, D A; Balossino, R; Benndorf, G; Hose, D R; Marzo, A; Metcalfe, R; Mortier, P; Mut, F; Reymond, P; Socci, L; Verhegghe, B; Frangi, A F

    2008-07-19

    This paper presents the results of the Virtual Intracranial Stenting Challenge (VISC) 2007, an international initiative whose aim was to establish the reproducibility of state-of-the-art haemodynamical simulation techniques in subject-specific stented models of intracranial aneurysms (IAs). IAs are pathological dilatations of the cerebral artery walls, which are associated with high mortality and morbidity rates due to subarachnoid haemorrhage following rupture. The deployment of a stent as flow diverter has recently been indicated as a promising treatment option, which has the potential to protect the aneurysm by reducing the action of haemodynamical forces and facilitating aneurysm thrombosis. The direct assessment of changes in aneurysm haemodynamics after stent deployment is hampered by limitations in existing imaging techniques and currently requires resorting to numerical simulations. Numerical simulations also have the potential to assist in the personalized selection of an optimal stent design prior to intervention. However, from the current literature it is difficult to assess the level of technological advancement and the reproducibility of haemodynamical predictions in stented patient-specific models. The VISC 2007 initiative engaged in the development of a multicentre-controlled benchmark to analyse differences induced by diverse grid generation and computational fluid dynamics (CFD) technologies. The challenge also represented an opportunity to provide a survey of available technologies currently adopted by international teams from both academic and industrial institutions for constructing computational models of stented aneurysms. The results demonstrate the ability of current strategies in consistently quantifying the performance of three commercial intracranial stents, and contribute to reinforce the confidence in haemodynamical simulation, thus taking a step forward towards the introduction of simulation tools to support diagnostics and

  19. Dexmedetomidine in Attenuation of Haemodynamic Response and Dose Sparing Effect on Opioid and Anaesthetic Agents in Patients undergoing Laparoscopic Cholecystectomy- A Randomized Study

    PubMed Central

    Bhagat, Nandlal; Karim, Habib Md Reazaul; Hajong, Ranendra; Bhattacharyya, Prithwis; Singh, Manorama

    2016-01-01

    Introduction Perioperative procedures are stressful and lead to haemodynamic instability with potentially devastating consequences. Dexmedetomidine is found to have many of the desired characteristics that are required in perioperative period. Aim To evaluate the ability of pre and intraoperative dexmedetomidine to attenuate stress induced haemodynamic responses, quantifying the anaesthetic agents sparing as well as its cost-effectiveness in patients undergoing laparoscopic cholecystectomy. Materials and Methods The present single blind randomized study was conducted with 120 ASA I and II consented patients who underwent laparoscopic cholecystectomy. Patients were randomly divided into 2 groups (i.e., group D and group N). Prior to induction, group D received 1 μg/kg of Dexmedetomidine and group N received Normal saline infusion over 20 minutes. Group D also received maintenance Dexmedetomidine intraoperatively. Bispectral index and minimum alveolar concentration monitoring was done in both the groups. Haemodynamic parameters were noted till 100 minutes post laryngoscopy. Opioid and anaesthetic agent consumptions were also noted and cost analysis was done. Medcalc–Version 12.5.0.0 software was used for statistics and p <0.05 was considered significant. Results Dexmedetomidine attenuated the stress induced haemodynamics responses and produced stable, relatively non fluctuating haemodynamics throughout. The Minimum Alveolar Concentration (MAC) requirement and the consumptions of Fentanyl and Isoflurane were significantly less in the Dexmedetomidine group (p<0.0001). However, despite anaesthetic dose sparing effect the anaesthetic technique was not cost-effective. Conclusion Dexmedetomidine is effective in attenuating haemodynamic responses in laparoscopic surgery and having dose sparing effect on Fentanyl, Propofol and Isoflurane. However, overall this technique is not cost-effective. PMID:28050479

  20. Numerical simulation of haemodynamics and low-density lipoprotein transport in the rabbit aorta and their correlation with atherosclerotic plaque thickness

    PubMed Central

    Liu, Xiao; Zhang, Peng; Feng, Chenglong; Sun, Anqiang; Kang, Hongyan; Deng, Xiaoyan; Fan, Yubo

    2017-01-01

    Two mechanisms of shear stress and mass transport have been recognized to play an important role in the development of localized atherosclerosis. However, their relationship and roles in atherogenesis are still obscure. It is necessary to investigate quantitatively the correlation among low-density lipoproteins (LDL) transport, haemodynamic parameters and plaque thickness. We simulated blood flow and LDL transport in rabbit aorta using computational fluid dynamics and evaluated plaque thickness in the aorta of a high-fat-diet rabbit. The numerical results show that regions with high luminal LDL concentration tend to have severely negative haemodynamic environments (HEs). However, for regions with moderately and slightly high luminal LDL concentration, the relationship between LDL concentration and the above haemodynamic indicators is not clear cut. Point-by-point correlation with experimental results indicates that severe atherosclerotic plaque corresponds to high LDL concentration and seriously negative HEs, less severe atherosclerotic plaque is related to either moderately high LDL concentration or moderately negative HEs, and there is almost no atherosclerotic plaque in regions with both low LDL concentration and positive HEs. In conclusion, LDL distribution is closely linked to blood flow transport, and the synergetic effects of luminal surface LDL concentration and wall shear stress-based haemodynamic indicators may determine plaque thickness. PMID:28424305

  1. Posture with elevated and extended thorax. The influence of the position on some haemodynamic and ventilatory parameters under general anaesthesia.

    PubMed

    Videbaek, F

    1980-12-01

    The effects of a change in posture from flat supine to supine with elevated and extended thorax have been investigated in 12 healthy patients under general anaesthesia prior to elective surgery on the stomach. The following parameters were measured: pulse rate, mean arterial blood pressure (MABP), central venous pressure (CVP), ventilation pressure, oesophageal pressure, and arterial oxygen and carbon dioxide tensions. Changes were measured as deviations from initial values before the change of position at 4 and 15 min after the change. One patient (8%) had a 31% fall in MABP and a 87% fall in CVP, requiring treatment outside the standard procedure, but acceptable values were obtained by simple means. Eleven patients showed only minor changes: a mean initial rise in pulse rate of 10% and a fall in CVP of 25%, after which the pulse rate returned to the initial level and the CVP remained stable. MABP was unchanged, as were ventilation pressure, oesophageal pressure and gas tensions. On the basis of reports in the literature and findings in this study, it is concluded that otherwise healthy patients tolerate the posture well, the slight risk of haemodynamic complications being outweighed by the surgical advantages. This posture should be used with caution in patients who may be haemodynamically unable to compensate.

  2. Reduced haemodynamic coupling and exercise are associated with vascular stiffening in pulmonary arterial hypertension.

    PubMed

    Bellofiore, Alessandro; Dinges, Eric; Naeije, Robert; Mkrdichian, Hamorabi; Beussink-Nelson, Lauren; Bailey, Melissa; Cuttica, Michael J; Sweis, Ranya; Runo, James R; Keevil, Jon G; Francois, Christopher J; Shah, Sanjiv J; Chesler, Naomi C

    2017-03-01

    Inadequate right ventricular (RV) and pulmonary arterial (PA) functional responses to exercise are important yet poorly understood features of pulmonary arterial hypertension (PAH). This study combined invasive catheterisation with echocardiography to assess RV afterload, RV function and ventricular-vascular coupling in subjects with PAH. Twenty-six subjects with PAH were prospectively recruited to undergo right heart catheterisation and Doppler echocardiography at rest and during incremental exercise, and cardiac MRI at rest. Measurements at rest included basic haemodynamics, RV function and coupling efficiency (η). Measurements during incremental exercise included pulmonary vascular resistance (Z 0 ), characteristic impedance (Z C , a measure of proximal PA stiffness) and proximal and distal PA compliance (C PA ). In patients with PAH, the proximal PAs were significantly stiffer at maximum exercise (Z C =2.31±0.38 vs 1.33±0.15 WU×m 2 at rest; p=0.003) and PA compliance was decreased (C PA =0.88±0.10 vs 1.32±0.17 mL/mm Hg/m 2 at rest; p=0.0002). Z 0 did not change with exercise. As a result, the resistance-compliance (RC) time decreased with exercise (0.67±0.05 vs 1.00±0.07 s at rest; p<10 -6 ). When patients were grouped according to resting coupling efficiency, those with poorer η exhibited stiffer proximal PAs at rest, a lower maximum exercise level, and more limited C PA reduction at maximum exercise. In PAH, exercise causes proximal and distal PA stiffening, which combined with preserved Z 0 results in decreased RC time with exercise. Stiff PAs at rest may also contribute to poor haemodynamic coupling, reflecting reduced pulmonary vascular reserve that contributes to limit the maximum exercise level tolerated. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Acute effects of Finnish sauna and cold-water immersion on haemodynamic variables and autonomic nervous system activity in patients with heart failure.

    PubMed

    Radtke, Thomas; Poerschke, Daniel; Wilhelm, Matthias; Trachsel, Lukas D; Tschanz, Hansueli; Matter, Friederike; Jauslin, Daniel; Saner, Hugo; Schmid, Jean-Paul

    2016-04-01

    The haemodynamic response to Finnish sauna and subsequent cold-water immersion in heart failure patients is unknown. Haemodynamic response to two consecutive Finnish sauna (80℃) exposures, followed by a final head-out cold-water immersion (12℃) was measured in 37 male participants: chronic heart failure (n = 12, 61.8 ± 9.2 years), coronary artery disease (n = 13, 61.2 ± 10.6 years) and control subjects (n = 12, 60.9 ± 8.9 years). Cardiac output was measured non-invasively with an inert gas rebreathing method prior to and immediately after the first sauna exposure and after cold-water immersion, respectively. Blood pressure was measured before, twice during and after sauna. The autonomic nervous system was assessed by power spectral analysis of heart rate variability. Total power, low-frequency and high-frequency components were evaluated. The low frequency/high frequency ratio was used as a marker of sympathovagal balance. Sauna and cold-water immersion were well tolerated by all subjects. Cardiac output and heart rate significantly increased in all groups after sauna and cold-water immersion (p < 0.05), except for coronary artery disease patients after sauna exposure. Systolic blood pressure during sauna decreased significantly in all groups with a nadir after 6 min (all p < 0.05). Cold-water immersion significantly increased systolic blood pressure in all groups (p < 0.05). No change in the low/high frequency ratio was found in chronic heart failure patients. In coronary artery disease patients and controls a prolonged increase in low frequency/high frequency ratio was observed after the first sauna exposure. Acute exposure to Finnish sauna and cold-water immersion causes haemodynamic alterations in chronic heart failure patients similarly to control subjects and in particular did not provoke an excessive increase in adrenergic activity or complex arrhythmias. © The European Society of Cardiology 2015.

  4. Lung recruitment manoeuvres do not cause haemodynamic instability or oxidative stress but improve oxygenation and lung mechanics in a newborn animal model: an observational study.

    PubMed

    de la Osa, Agustín Mendiola; Garcia-Fernandez, Javier; Llorente-Cantarero, Francisco J; Gil-Campos, Mercedes; Muñoz-Villanueva, María C; De la Torre Aguilar, María J; de la Rosa, Ignacio Ibarra; Pérez-Navero, Juan L

    2014-09-01

    Lung recruitment manoeuvres in neonates during anaesthesia are not performed routinely due to concerns about causing barotrauma, haemodynamic instability and oxidative stress. To assess the influence of recruitment manoeuvres and positive end-expiratory pressure (PEEP) on haemodynamics, oxidative stress, oxygenation and lung mechanics. A prospective experimental study. Experimental Unit, La Paz University Hospital, Madrid, Spain. Eight newborn piglets (<48 h) with healthy lungs under general anaesthesia. The recruitment manoeuvres in pressure-controlled ventilation (PCV) were performed along with a constant driving pressure of 15 cmH2O. After the recruitment manoeuvres, PEEP was reduced in a stepwise fashion to find the maximal dynamic compliance step (maxCDyn-PEEP). Blood oxidative stress biomarkers (lipid peroxidation products, protein carbonyls, total glutathione, oxidised glutathione, reduced glutathione and activity of glutathione peroxidase) were analysed. Haemodynamic parameters, arterial partial pressure of oxygen (paO2), tidal volume (Vt), dynamic compliance (Cdyn) and oxidative stress biomarkers were measured. The recruitment manoeuvres did not induce barotrauma. Haemodynamic instability was not detected either in the maximum pressure step (overdistension step 5) or during the entire process. No substantial differences were observed in blood oxidative stress parameters analysed as compared with their baseline values (with 0 PEEP) or the values obtained 180 min after the onset of the recruitment manoeuvres (optimal PEEP). Significant maximal values were achieved in step 14 with an increase in paO2 (32.43 ± 8.48 vs. 40.39 ± 15.66 kPa; P = 0.037), Vt (47.75 ± 13.59 vs. 73.87 ± 13.56 ml; P = 0.006) and Cdyn (2.50 ± 0.64 vs. 4.75 ± 0.88 ml cmH2O; P < 0.001). Maximal dynamic compliance step (maxCdyn-PEEP) was 2 cmH2O. Recruitment manoeuvres in PCV with a constant driving pressure are a well tolerated open

  5. Haemodynamic effects of adrenaline (epinephrine) depend on chest compression quality during cardiopulmonary resuscitation in pigs.

    PubMed

    Pytte, Morten; Kramer-Johansen, Jo; Eilevstjønn, Joar; Eriksen, Morten; Strømme, Taevje A; Godang, Kristin; Wik, Lars; Steen, Petter Andreas; Sunde, Kjetil

    2006-12-01

    Adrenaline (epinephrine) is used during cardiopulmonary resuscitation (CPR) based on animal experiments without supportive clinical data. Clinically CPR was reported recently to have much poorer quality than expected from international guidelines and what is generally done in laboratory experiments. We have studied the haemodynamic effects of adrenaline during CPR with good laboratory quality and with quality simulating clinical findings and the feasibility of monitoring these effects through VF waveform analysis. After 4 min of cardiac arrest, followed by 4 min of basic life support, 14 pigs were randomised to ClinicalCPR (intermittent manual chest compressions, compression-to-ventilation ratio 15:2, compression depth 30-38 mm) or LabCPR (continuous mechanical chest compressions, 12 ventilations/min, compression depth 45 mm). Adrenaline 0.02 mg/kg was administered 30 s thereafter. Plasma adrenaline concentration peaked earlier with LabCPR than with ClinicalCPR, median (range), 90 (30, 150) versus 150 (90, 270) s (p = 0.007), respectively. Coronary perfusion pressure (CPP) and cortical cerebral blood flow (CCBF) increased and femoral blood flow (FBF) decreased after adrenaline during LabCPR (mean differences (95% CI) CPP 17 (6, 29) mmHg (p = 0.01), FBF -5.0 (-8.8, -1.2) ml min(-1) (p = 0.02) and median difference CCBF 12% of baseline (p = 0.04)). There were no significant effects during ClinicalCPR (mean differences (95% CI) CPP 4.7 (-3.2, 13) mmHg (p = 0.2), FBF -0.2 (-4.6, 4.2) ml min(-1)(p = 0.9) and CCBF 3.6 (-1.8, 9.0)% of baseline (p = 0.15)). Slope VF waveform analysis reflected changes in CPP. Adrenaline improved haemodynamics during laboratory quality CPR in pigs, but not with quality simulating clinically reported CPR performance.

  6. HACE1-dependent protein degradation provides cardiac protection in response to haemodynamic stress

    NASA Astrophysics Data System (ADS)

    Zhang, Liyong; Chen, Xin; Sharma, Parveen; Moon, Mark; Sheftel, Alex D.; Dawood, Fayez; Nghiem, Mai P.; Wu, Jun; Li, Ren-Ke; Gramolini, Anthony O.; Sorensen, Poul H.; Penninger, Josef M.; Brumell, John H.; Liu, Peter P.

    2014-03-01

    The HECT E3 ubiquitin ligase HACE1 is a tumour suppressor known to regulate Rac1 activity under stress conditions. HACE1 is increased in the serum of patients with heart failure. Here we show that HACE1 protects the heart under pressure stress by controlling protein degradation. Hace1 deficiency in mice results in accelerated heart failure and increased mortality under haemodynamic stress. Hearts from Hace1-/- mice display abnormal cardiac hypertrophy, left ventricular dysfunction, accumulation of LC3, p62 and ubiquitinated proteins enriched for cytoskeletal species, indicating impaired autophagy. Our data suggest that HACE1 mediates p62-dependent selective autophagic turnover of ubiquitinated proteins by its ankyrin repeat domain through protein-protein interaction, which is independent of its E3 ligase activity. This would classify HACE1 as a dual-function E3 ligase. Our finding that HACE1 has a protective function in the heart in response to haemodynamic stress suggests that HACE1 may be a potential diagnostic and therapeutic target for heart disease.

  7. Cardiac autonomic and haemodynamic recovery after a single session of aerobic exercise with and without blood flow restriction in older adults.

    PubMed

    Ferreira, Marina Lívia Venturini; Sardeli, Amanda Veiga; Souza, Giovana Vergínia De; Bonganha, Valéria; Santos, Lucas Do Carmo; Castro, Alex; Cavaglieri, Cláudia Regina; Chacon-Mikahil, Mara Patrícia Traina

    2017-12-01

    This study investigated the autonomic and haemodynamic responses to different aerobic exercise loads, with and without blood flow restriction (BFR). In a crossover study, 21 older adults (8 males and 13 females) completed different aerobic exercise sessions: low load without BFR (LL) (40% VO 2 max ), low load with BFR (LL-BFR) (40% VO 2 max + 50% BFR) and high load without BFR (HL) (70% VO 2 max ). Heart rate variability and haemodynamic responses were recorded during rest and throughout 30 min of recovery. HL reduced R-R interval, the root mean square of successive difference of R-R intervals and high frequency during 30 min of recovery at a greater magnitude compared with LL and LL-BFR. Sympathetic-vagal balance increased the values for HL during 30 min of recovery at a greater magnitude when compared with LL and LL-BFR. Post-exercise haemodynamic showed reduced values of double product at 30 min of recovery compared to rest in LL-BFR, while HL showed higher values compared to rest, LL-BFR and LL. Reduced systolic blood pressure was observed for LL-BFR (30 min) compared to rest. Autonomic and haemodynamic responses indicate lower cardiovascular stress after LL-BFR compared to HL, being this method, besides the functional adaptations, a potential choice to attenuate the cardiovascular stress after exercise in older adults.

  8. Randomised controlled cross-over comparison of continuous positive airway pressure through the Hamilton Galileo ventilator with a Dräger CF 800 device.

    PubMed

    Sutton, P J; Perkins, C L; Giles, S P; McAuley, D F; Gao, F

    2005-01-01

    In this controlled, randomised cross-over trial on 26 intensive care patients, we compared the effects on haemodynamic and respiratory profiles of continuous positive airway pressure delivered through the Hamilton Galileo ventilator or a Drager CF 800 device. We also compared the nursing time saved using the two approaches when weaning patients from mechanical ventilation. We did not find significant differences in haemodynamics, respiratory rate, physiological dead space, oxygen saturation and carbon dioxide production between the continuous positive airway pressure generated by the Galileo and Drager machines. However, there was a 10-fold reduction in nursing time using the Galileo ventilator compared with the Drager generator. We conclude that continuous positive airway pressure delivered through the Galileo ventilator is as efficient as a Drager device but consumes less nursing time.

  9. Effective Measures of Continuing Education

    DTIC Science & Technology

    2013-03-01

    with increased participation in charitable or public service activities. The percentage of people who donate their time to organizations and the... Effective Measures of Continuing Education by Colonel Morris A. Turner United States Army United...STRATEGY RESEARCH PROJECT .33 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Effective Measures of Continuing Education 5a. CONTRACT

  10. The effect of low molecular weight dextran on haemodynamics and respiratory function during endotoxin-induced shock.

    PubMed Central

    Christenson, J T; al-Sarraf, A; Abu-Saleh, R

    1992-01-01

    The effects of low molecular weight dextran (LMWD) infusion, on gas exchange and haemodynamics were evaluated in sheep during endotoxin shock. The infusion of LMWD was started after signs of shock and lung injury were evident. After a stabilization period 10 micrograms kg-1 E. Coli endotoxin was infused i.v.. Endotoxin infusion resulted in an marked increase in pulmonary artery pressure (PAP) and decrease in mean arterial pressure (MAP), respiratory compliance, arterial oxygen tension (PaO2) and oxygen delivery index (DO2l). After 3 h MAP, PaO2, DO2l and compliance improved significantly in LMWD treated animals. The PAP had also decreased significantly in the LMWD-treated animals, but remained high in the controls (P less than 0.01). It was concluded that LMWD infusion improves haemodynamics and gas-exchange in sheep during endotoxin shock. PMID:1373624

  11. NOTE: Haemodynamic resistance model of monochorionic twin pregnancies complicated by acardiac twinning

    NASA Astrophysics Data System (ADS)

    Umur, Asli; van Gemert, Martin J. C.; van den Wijngaard, Jeroen P. H. M.; Ross, Michael G.; Nikkels, Peter G. J.

    2004-07-01

    An acardiac twin is a severely malformed monochorionic twin fetus that lacks most organs, particularly a heart. It grows during pregnancy, because it is perfused by its developmentally normal co-twin (called the pump twin) via a set of placental arterioarterial and venovenous anastomoses. The pump twin dies intrauterine or neonatally in about 50% of the cases due to congestive heart failure, polyhydramnios and prematurity. Because the pathophysiology of this pregnancy is currently incompletely understood, we modified our previous haemodynamic model of monochorionic twins connected by placental vascular anastomoses to include the analysis of acardiac twin pregnancies. We incorporated the fetoplacental circulation as a resistance circuit and used the fetal umbilical flow that perfuses the body to define fetal growth, rather than the placental flow as done previously. Using this modified model, we predicted that the pump twin has excess blood volume and increased mean arterial blood pressure compared to those in the acardiac twin. Placental perfusion of the acardiac twin is significantly reduced compared to normal, as a consequence of an increased venous pressure, possibly implying reduced acardiac placental growth. In conclusion, the haemodynamic analysis may contribute to an increased knowledge of the pathophysiologic consequences of an acardiac body mass for the pump twin.

  12. Continuous Odour Measurement with Chemosensor Systems

    NASA Astrophysics Data System (ADS)

    Boeker, Peter; Haas, T.; Diekmann, B.; Lammer, P. Schulze

    2009-05-01

    The continuous odour measurement is a challenging task for chemosensor systems. Firstly, a long term and stable measurement mode must be guaranteed in order to preserve the validity of the time consuming and expensive olfactometric calibration data. Secondly, a method is needed to deal with the incoming sensor data. The continuous online detection of signal patterns, the correlated gas emission and the assigned odour data is essential for the continuous odour measurement. Thirdly, a severe danger of over-fitting in the process of the odour calibration is present, because of the high measurement uncertainty of the olfactometry. In this contribution we present a technical solution for continuous measurements comprising of a hybrid QMB-sensor array and electrochemical cells. A set of software tools enables the efficient data processing and calibration and computes the calibration parameters. The internal software of the measurement systems microcontroller processes the calibration parameters online for the output of the desired odour information.

  13. Measurement Properties of Questionnaires Measuring Continuity of Care: A Systematic Review

    PubMed Central

    Uijen, Annemarie A.; Heinst, Claire W.; Schellevis, Francois G.; van den Bosch, Wil J.H.M.; van de Laar, Floris A.; Terwee, Caroline B.; Schers, Henk J.

    2012-01-01

    Background Continuity of care is widely acknowledged as a core value in family medicine. In this systematic review, we aimed to identify the instruments measuring continuity of care and to assess the quality of their measurement properties. Methods We did a systematic review using the PubMed, Embase and PsycINFO databases, with an extensive search strategy including ‘continuity of care’, ‘coordination of care’, ‘integration of care’, ‘patient centered care’, ‘case management’ and its linguistic variations. We searched from 1995 to October 2011 and included articles describing the development and/or evaluation of the measurement properties of instruments measuring one or more dimensions of continuity of care (1) care from the same provider who knows and follows the patient (personal continuity), (2) communication and cooperation between care providers in one care setting (team continuity), and (3) communication and cooperation between care providers in different care settings (cross-boundary continuity). We assessed the methodological quality of the measurement properties of each instrument using the COSMIN checklist. Results We included 24 articles describing the development and/or evaluation of 21 instruments. Ten instruments measured all three dimensions of continuity of care. Instruments were developed for different groups of patients or providers. For most instruments, three or four of the six measurement properties were assessed (mostly internal consistency, content validity, structural validity and construct validity). Six instruments scored positive on the quality of at least three of six measurement properties. Conclusions Most included instruments have problems with either the number or quality of its assessed measurement properties or the ability to measure all three dimensions of continuity of care. Based on the results of this review, we recommend the use of one of the four most promising instruments, depending on the target

  14. Time course of haemodynamic, respiratory and inflammatory disturbances induced by experimental acute pulmonary polystyrene microembolism.

    PubMed

    Dolci, Daniel T; Fuentes, Carolina B; Rolim, Denise; Park, Marcelo; Schettino, Guilherme P P; Azevedo, Luciano C P

    2010-01-01

    The time course of cardiopulmonary alterations after pulmonary embolism has not been clearly demonstrated and nor has the role of systemic inflammation on the pathogenesis of the disease. This study aimed to evaluate over 12 h the effects of pulmonary embolism caused by polystyrene microspheres on the haemodynamics, lung mechanics and gas exchange and on interleukin-6 production. Ten large white pigs (weight 35-42 kg) had arterial and pulmonary catheters inserted and pulmonary embolism was induced in five pigs by injection of polystyrene microspheres (diameter approximately 300 micromol l(-1)) until a value of pulmonary mean arterial pressure of twice the baseline was obtained. Five other animals received only saline. Haemodynamic and respiratory data and pressure-volume curves of the respiratory system were collected. A bronchoscopy was performed before and 12 h after embolism, when the animals were euthanized. The embolism group developed hypoxaemia that was not corrected with high oxygen fractions, as well as higher values of dead space, airway resistance and lower respiratory compliance levels. Acute haemodynamic alterations included pulmonary arterial hypertension with preserved systemic arterial pressure and cardiac index. These derangements persisted until the end of the experiments. The plasma interleukin-6 concentrations were similar in both groups; however, an increase in core temperature and a nonsignificant higher concentration of bronchoalveolar lavage proteins were found in the embolism group. Acute pulmonary embolism induced by polystyrene microspheres in pigs produces a 12-h lasting hypoxaemia and a high dead space associated with high airway resistance and low compliance. There were no plasma systemic markers of inflammation, but a higher central temperature and a trend towards higher bronchoalveolar lavage proteins were found.

  15. Intraseptal vs. periodontal ligament anaesthesia for maxillary tooth extraction: quality of local anaesthesia and haemodynamic response.

    PubMed

    Brkovic, Bozidar M B; Savic, Miroslav; Andric, Miroslav; Jurisic, Milan; Todorovic, Ljubomir

    2010-12-01

    There is no data concerning the use of the intraseptal anaesthesia (ISA) for single tooth extraction. The aims of this study were to compare the clinical efficacy and haemodynamic responses of the ISA with the periodontal ligament anaesthesia (PLA) for single tooth extraction. Thirty-five randomly selected healthy patients (ASA I) undergoing maxillary lateral incisors extraction entered the study. Onset of anaesthesia, the width of the anaesthetic field and duration of anaesthesia were recorded by pinprick testing. Intensity of anaesthesia was evaluated on a visual analogue scale. Haemodynamic parameters were recorded simultaneously at different time points after anaesthesia injection. The two techniques of local anaesthesia did not show statistically significant differences regarding the success rate and onset of anaesthesia, while the duration of the ISA on the buccal site was significantly longer in comparison with the PLA. The intensity of the achieved anaesthesia, estimated by the experienced pain during procedure, pointed out that pain was recorded in 24% of cases in the ISA group, and in 19% in the PLA group without significant differences. Postoperative pain was found to be smaller in the ISA group (70.9% of treated sites) than in the PLA group (81.3% of treated sites); however, this difference was not significant. Although the heart rate increased in both groups, there were no significant differences in the patients' haemodynamic response between the ISA and the PLA. The results of the present study indicate that both techniques are useful and suitable for the routine tooth extraction.

  16. Effect-site concentration of remifentanil required to blunt haemodynamic responses during tracheal intubation: A randomized comparison between single- and double-lumen tubes.

    PubMed

    Kim, Tae Kyong; Hong, Deok Man; Lee, Seo Hee; Paik, Hyesun; Min, Se Hee; Seo, Jeong-Hwa; Jung, Chul-Woo; Bahk, Jae-Hyon

    2018-01-01

    Objective To investigate the effect-site concentration of remifentanil required to blunt haemodynamic responses during tracheal intubation with a single-lumen tube (SLT) or a double-lumen tube (DLT). Methods Patients scheduled for thoracic surgery requiring one-lung ventilation were randomly allocated to either the SLT or DLT group. All patients received a target-controlled infusion of propofol and a predetermined concentration of remifentanil. Haemodynamic parameters during intubation were recorded. The effect-site concentration of remifentanil was determined using a delayed up-and-down sequential allocation method. Results A total of 92 patients were enrolled in the study. The effective effect-site concentrations of remifentanil required to blunt haemodynamic responses in 50% of patients (EC 50 ) estimated by isotonic regression with bootstrapping was higher in the DLT than the SLT group (8.5 ng/ml [95% confidence interval (CI) 8.0-9.5 ng/ml] versus 6.5 ng/ml [95% CI 5.6-6.7 ng/ml], respectively). Similarly, the effective effect-site concentrations of remifentanil in 95% of patients in the DLT group was higher than the SLT group (9.9 ng/ml [95% CI 9.8-10.0 ng/ml] versus 7.0 ng/ml [95% CI 6.9-7.0 ng/ml], respectively). Conclusions This study demonstrated that a DLT requires a 30% higher EC 50 of remifentanil than does an SLT to blunt haemodynamic responses during tracheal intubation when combined with a target-controlled infusion of propofol. Trial registration Clinicaltrials.gov identifier: NCT01542099.

  17. Immediate central and peripheral haemodynamic effects of a new vasodilating agent Pinacidil (P1134) in hypertensive man.

    PubMed

    Carlsen, J E; Kardel, T; Hilden, T; Tangø, M; Trap-Jensen, J

    1981-08-01

    The purpose of this study was to evaluate the immediate central and peripheral haemodynamic effects of a new vasodilating agent P 1134, in hypertensive man. After oral administration of 25 mg P 1134, the maximal haemodynamic changes were (mean +/- 1 SEM): mean blood pressure fell from 121.8 +/- 6.5 to 80.5 +/- 7.8 mmHg, heart rate increased 24.2 +/- 4.5 beats/min, cardiac output rose 2.9 +/- 0.3 1/min and forearm blood flow increased 1.0 +/- 0.1 ml/100 ml tissue/min. Stroke volume increased 17.0 +/- 2.1 ml and the inotropic state of the heart as judged from systolic time intervals increased. Total peripheral resistance and forearm vascular resistance were both reduced by approx. 50%. Linear correlations were found between the serum concentration of P 1134 and the change in mean blood pressure and total peripheral resistance. Changes in the other parameters mentioned above occurred progressively with changes in mean blood pressure and total peripheral resistance. It can be concluded that P 1134 is a very potent hypotensive agent with a haemodynamic profile identical to that seen with vasodilators with preferably act on precapillary resistance vessels. Potency and maximal efficacy exceeds that of hydralazine and seems like that of minoxidil. P 1134 is remarkably free from side-effects apart from causing water retention as all other vasodilators. It can be administered orally as well as intravenously. This makes P 1134 a very interesting compound in the treatment of moderate to severe hypertension, and further studies are well-founded.

  18. Comparison of the effects of antihypertensive treatment with angiotensin II blockade and beta-blockade on carotid wall structure and haemodynamics: protocol and baseline demographics.

    PubMed

    Ariff, Ben; Stanton, Alice; Barratt, Dean; Augst, Alex; Glor, Fadi; Poulter, Neil; Sever, Peter; Xu, Yun; Hughes, Alun; Thom, Simon A Mc G

    2002-06-01

    Several systemic factors have been shown to contribute to the acceleration of large vessel atheroma. Correction of these factors leads to a reduction in the progression of plaque formation and associated arterial wall thickness. Atheroma remains, however, a focal disease, developing at characteristic sites within the arterial tree. These sites are typically at areas of vessel branching or marked curvature, and correspond to regions of high tensile stress and low sheer stress, leading to the hypothesis that local haemodynamic factors and vessel wall mechanics potentiate the focal development of atheroma. Current assessment of vascular haemodynamics suffers from an inability to handle complex flow, and does not allow accurate determination of locally varying flow, and shear stress patterns. The application of computational fluid dynamic (CFD) flow simulation techniques to ultrasound and local pressure data, however, allows a comprehensive, non-invasive appraisal of haemodynamic flow parameters to be performed. The Candesartan cilexetil and Atenolol Carotid Haemodynamic Endpoint Trial (CACHET) study compares the effects of two antihypertensive regimens, one b-blocker-based, the other angiotensin receptor blocker based, on carotid intima-media thickness. The collection of ultrasound and pressure data on each subject provides a unique opportunity to apply these data to the CFD model to study the effects of these antihypertensive regimens on local fluid dynamics. This will lead to a greater understanding of the relationship of these factors to atheroma formation and regression.

  19. [Comprehensive monitoring of cerebral haemodynamics during surgical interventions on brachiocephalic arteries].

    PubMed

    Ignat'ev, I M; Bredikhin, R A; Falina, T G; Vinogradova, V V; Khismatullina, L I

    2010-01-01

    The authors analysed a total of 152 surgical interventions on the brachiocephalic arteries (BCAs) performed in 142 patients. All the patients were subjected to intraoperative monitoring of cerebral haemodynamics by means of transcranial Doppler (TCD) ultrasonography simultaneously accompanied by electroencephalography (EEG). Additionally, the state of the reconstructed carotid arteries was controlled by means of ultrasonographic duplex scanning (USDS). Comparing the findings of the TCD recording and EEG made it possible to single out 5 groups of the operated patients. The EEG technique turned out to have more informative value as compared with TCD ultrasonography in determining the degree of cerebral ischaemia during clamping of the carotid arteries (CAs). Nine (5.9%) patients demonstrated lower tolerance of the brain to ischaemia, and the operation on the BCA was performed with the use of a temporal intraluminal bypass graft. Microembolic signals (MES) were registered in 54.6% of cases. Single MES were detected in six patients, sporadic MES--in 53, and multiple MES--in 24. Mention should be made that the--MES associated with the placement of the bypass graft appeared to be multiple and were registered in all the operated patients. Diffusion-weighted magnetic resonance tomography revealed fresh foci of lacunar cerebral infarctions in 14 (25%) of the 56 patients thus examined. Intraoperative USDS of the reconstructed carotid arteries revealed floatation of the residual remnants of the intima in two patients, which was the cause of a repeat intervention. Combined monitoring of cerebral haemodynamics makes it possible to timely prevent cerebral ischaemia, to narrow the indications for placement of an intraluminal bypass graft, and to dramatically decrease the rate of postoperative complications.

  20. Virtual continuity of measurable functions and its applications

    NASA Astrophysics Data System (ADS)

    Vershik, A. M.; Zatitskii, P. B.; Petrov, F. V.

    2014-12-01

    A classical theorem of Luzin states that a measurable function of one real variable is `almost' continuous. For measurable functions of several variables the analogous statement (continuity on a product of sets having almost full measure) does not hold in general. The search for a correct analogue of Luzin's theorem leads to a notion of virtually continuous functions of several variables. This apparently new notion implicitly appears in the statements of embedding theorems and trace theorems for Sobolev spaces. In fact it reveals the nature of such theorems as statements about virtual continuity. The authors' results imply that under the conditions of Sobolev theorems there is a well-defined integration of a function with respect to a wide class of singular measures, including measures concentrated on submanifolds. The notion of virtual continuity is also used for the classification of measurable functions of several variables and in some questions on dynamical systems, the theory of polymorphisms, and bistochastic measures. In this paper the necessary definitions and properties of admissible metrics are recalled, several definitions of virtual continuity are given, and some applications are discussed. Bibliography: 24 titles.

  1. A randomised study of perioperative esmolol infusion for haemodynamic stability during major vascular surgery; rationale and design of DECREASE-XIII.

    PubMed

    Bakker, E J; Ravensbergen, N J; Voute, M T; Hoeks, S E; Chonchol, M; Klimek, M; Poldermans, D

    2011-09-01

    This article describes the rationale and design of the DECREASE-XIII trial, which aims to evaluate the potential of esmolol infusion, an ultra-short-acting beta-blocker, during surgery as an add-on to chronic low-dose beta-blocker therapy to maintain perioperative haemodynamic stability during major vascular surgery. A double-blind, placebo-controlled, randomised trial. A total of 260 vascular surgery patients will be randomised to esmolol or placebo as an add-on to standard medical care, including chronic low-dose beta-blockers. Esmolol is titrated to maintain a heart rate within a target window of 60-80 beats per minute for 24 h from the induction of anaesthesia. Heart rate and ischaemia are assessed by continuous 12-lead electrocardiographic monitoring for 72 h, starting 1 day prior to surgery. The primary outcome measure is duration of heart rate outside the target window during infusion of the study drug. Secondary outcome measures will be the efficacy parameters of occurrence of cardiac ischaemia, troponin T release, myocardial infarction and cardiac death within 30 days after surgery and safety parameters such as the occurrence of stroke and hypotension. This study will provide data on the efficacy of esmolol titration in chronic beta-blocker users for tight heart-rate control and reduction of ischaemia in patients undergoing vascular surgery as well as data on safety parameters. Copyright © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Aortic blood pressure measured via EIT: investigation of different measurement settings.

    PubMed

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Adler, Andy; Grychtol, Bartłomiej; Solà, Josep; Thiran, Jean-Philippe

    2015-06-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.

  3. Systolic blood pressure is superior to other haemodynamic predictors of outcome in community acquired pneumonia.

    PubMed

    Chalmers, J D; Singanayagam, A; Hill, A T

    2008-08-01

    Admission blood pressure (BP) assessment is a central component of severity assessment for community acquired pneumonia. The aim of this study was to establish which readily available haemodynamic measure on admission is most useful for predicting severity in patients admitted with community acquired pneumonia. A prospective observational study of patients admitted with community acquired pneumonia was conducted in Edinburgh, UK. The measurements compared were systolic and diastolic BP, mean arterial pressure and pulse pressure. The outcomes of interest were 30 day mortality and the requirement for mechanical ventilation and/or inotropic support. Admission systolic BP < 90 mm Hg, diastolic BP < or = 60 mm Hg, mean arterial pressure < 70 mm Hg and pulse pressure < or = 40 mm Hg were all associated with increased 30 day mortality and the need for mechanical ventilation and/or inotropic support on multivariate logistic regression. The AUC values for each predictor of 30 day mortality were as follows: systolic BP < 90 mm Hg 0.70; diastolic BP < or = 60 mm Hg 0.59; mean arterial pressure < 70 mm Hg 0.64; and pulse pressure < or = 40 mm Hg 0.60. The AUC values for each predictor of need for mechanical ventilation and/or inotropic support were as follows: systolic BP < 90 mm Hg 0.70; diastolic BP < or = 60 mm Hg 0.68; mean arterial pressure < 70 mm Hg 0.69; and pulse pressure < or = 40 mm Hg 0.59. A simplified CRB65 score containing systolic blood pressure < 90 mm Hg alone performed equally well to standard CRB65 score (AUC 0.76 vs 0.74) and to the standard CURB65 score (0.76 vs 0.76) for the prediction of 30 day mortality. The simplified CRB65 score was equivalent for prediction of mechanical ventilation and/or inotropic support to standard CRB65 (0.77 vs 0.77) and to CURB65 (0.77 vs 0.78). Systolic BP is superior to other haemodynamic predictors of 30 day mortality and need for mechanical ventilation and/or inotropic support in community acquired pneumonia. The CURB65

  4. Studies of the haemodynamic effects of creatine phosphate in man.

    PubMed Central

    Hurlow, R A; Aukland, A; Hardman, J; Whittington, J R

    1982-01-01

    1 The haemodynamic effects of intravenous creatine phosphate 1000 mg have been studied. 2 During the first 60 min following drug administration heart rate and blood pressure did not change but cardiac output fell significantly by approximately 18%. Calculated total peripheral resistance showed a corresponding significant rise, the maximum increase being approximately 24%. All these changes were beginning to diminish within 90 min after the injection. 3 Total limb blood flow measured in both arm and leg (using venous occlusion strain-gauge plethysmography) showed no appreciable changes following injection of creatine phosphate. 4 There was a progressive reduction in leg muscle blood flow (Xe133 clearance method) following injection which was statistically significant with respect to the initial level and reached a minimum (46% reduction) 50 min after the injection. 5 Skin blood flow, estimated by infra-red photoplethysmography, showed changes complementary to those seen with muscle flow. There was a progressive and significant rise to a peak (73% increase) 30 min after the injection. 6 No adverse reactions to the injections were noted. 7 Reduced cardiac output in the absence of altered total limb blood flow presumably reflects a reduction in visceral blood flow, which was not measured in this study. Within the limbs, creatine phosphate appears to result in a redistribution of blood flow from muscle to skin. Thus, these preliminary results suggest that intravenous creatine phosphate could be clinically useful in situations where short term improvement in skin blood flow would be advantageous and that further controlled studies would be justified. PMID:7093109

  5. The action uncertainty principle for continuous measurements

    NASA Astrophysics Data System (ADS)

    Mensky, Michael B.

    1996-02-01

    The action uncertainty principle (AUP) for the specification of the most probable readouts of continuous quantum measurements is proved, formulated in different forms and analyzed (for nonlinear as well as linear systems). Continuous monitoring of an observable A(p,q,t) with resolution Δa( t) is considered. The influence of the measurement process on the evolution of the measured system (quantum measurement noise) is presented by an additional term δ F(t)A(p,q,t) in the Hamiltonian where the function δ F (generalized fictitious force) is restricted by the AUP ∫|δ F(t)| Δa( t) d t ≲ and arbitrary otherwise. Quantum-nondemolition (QND) measurements are analyzed with the help of the AUP. A simple uncertainty relation for continuous quantum measurements is derived. It states that the area of a certain band in the phase space should be of the order of. The width of the band depends on the measurement resolution while its length is determined by the deviation of the system, due to the measurement, from classical behavior.

  6. The haemodynamic effects of intravenous paracetamol (acetaminophen) in healthy volunteers: a double-blind, randomized, triple crossover trial.

    PubMed

    Chiam, Elizabeth; Weinberg, Laurence; Bailey, Michael; McNicol, Larry; Bellomo, Rinaldo

    2016-04-01

    The haemodynamic effects of intravenous paracetamol have not been systematically investigated. We compared the physiological effects of intravenous mannitol-containing paracetamol, and an equivalent dosage of mannitol, and normal saline 0.9% in healthy volunteers. We performed a blinded, triple crossover, randomized trial of 24 adult healthy volunteers. Participants received i.v. paracetamol (1 g paracetamol +3.91 g mannitol 100 ml(-1) ), i.v. mannitol (3.91 g mannitol 100 ml(-1) ) and i.v. normal saline (100 ml). Composite primary end points were changes in mean arterial pressure (MAP), systolic blood pressure (SBP) and diastolic blood pressure (DBP) measured pre-infusion, during a 15 min infusion period and over a 45 min observation period. Systemic vascular resistance index (SVRI) and cardiac index were measured at the same time points. Infusion of paracetamol induced a transient yet significant decrease in blood pressures from pre-infusion values (MAP -1.85 mmHg, 95% CI -2.6, -1.1, SBP -0.54 mmHg, 95% CI -1.7, 0.6 and DBP -1.92 mmHg, 95% CI -2.6, -1.2, P < 0.0001), associated with a transient reduction in SVRI and an increase in cardiac index. Changes were observed, but to a lesser extent with normal saline (MAP -0.15 mmHg, SBP +1.44 mmHg, DBP --0.73 mmHg, P < 0.0001), but not with mannitol (MAP +1.47 mmHg, SBP +4.03 mmHg, DBP +0.48 mmHg, P < 0.0001). I.v. paracetamol caused a transient decrease in blood pressure immediately after infusion. These effects were not seen with mannitol or normal saline. The physiological mechanism was consistent with vasodilatation. This study provides plausible physiological data in a healthy volunteer setting, supporting transient changes in haemodynamic variables with i.v. paracetamol and justifies controlled studies in the peri-operative and critical care setting. © 2015 The British Pharmacological Society.

  7. Continuous inhaled iloprost in a neonate with d-transposition of the great arteries and severe pulmonary arterial hypertension.

    PubMed

    Dykes, John C; Torres, Marilyn; Alexander, Plato J

    2016-03-01

    This report describes the case of a neonate with d-transposition of the great arteries and severe pulmonary arterial hypertension stabilised in the post-operative period with continuous iloprost nebulisation. To our knowledge, this is the first documented method of treating post-operative severe pulmonary arterial hypertension with continuous inhaled iloprost in a patient with complex CHD. We found this method of delivering the drug very effective in stabilising haemodynamic swings in the setting of severe pulmonary arterial hypertension.

  8. Continuous measurement of an atomic current

    NASA Astrophysics Data System (ADS)

    Laflamme, C.; Yang, D.; Zoller, P.

    2017-04-01

    We are interested in dynamics of quantum many-body systems under continuous observation, and its physical realizations involving cold atoms in lattices. In the present work we focus on continuous measurement of atomic currents in lattice models, including the Hubbard model. We describe a Cavity QED setup, where measurement of a homodyne current provides a faithful representation of the atomic current as a function of time. We employ the quantum optical description in terms of a diffusive stochastic Schrödinger equation to follow the time evolution of the atomic system conditional to observing a given homodyne current trajectory, thus accounting for the competition between the Hamiltonian evolution and measurement back action. As an illustration, we discuss minimal models of atomic dynamics and continuous current measurement on rings with synthetic gauge fields, involving both real space and synthetic dimension lattices (represented by internal atomic states). Finally, by "not reading" the current measurements the time evolution of the atomic system is governed by a master equation, where—depending on the microscopic details of our CQED setups—we effectively engineer a current coupling of our system to a quantum reservoir. This provides interesting scenarios of dissipative dynamics generating "dark" pure quantum many-body states.

  9. Wide-field optical mapping of neural activity and brain haemodynamics: considerations and novel approaches

    PubMed Central

    Ma, Ying; Shaik, Mohammed A.; Kozberg, Mariel G.; Thibodeaux, David N.; Zhao, Hanzhi T.; Yu, Hang

    2016-01-01

    Although modern techniques such as two-photon microscopy can now provide cellular-level three-dimensional imaging of the intact living brain, the speed and fields of view of these techniques remain limited. Conversely, two-dimensional wide-field optical mapping (WFOM), a simpler technique that uses a camera to observe large areas of the exposed cortex under visible light, can detect changes in both neural activity and haemodynamics at very high speeds. Although WFOM may not provide single-neuron or capillary-level resolution, it is an attractive and accessible approach to imaging large areas of the brain in awake, behaving mammals at speeds fast enough to observe widespread neural firing events, as well as their dynamic coupling to haemodynamics. Although such wide-field optical imaging techniques have a long history, the advent of genetically encoded fluorophores that can report neural activity with high sensitivity, as well as modern technologies such as light emitting diodes and sensitive and high-speed digital cameras have driven renewed interest in WFOM. To facilitate the wider adoption and standardization of WFOM approaches for neuroscience and neurovascular coupling research, we provide here an overview of the basic principles of WFOM, considerations for implementation of wide-field fluorescence imaging of neural activity, spectroscopic analysis and interpretation of results. This article is part of the themed issue ‘Interpreting BOLD: a dialogue between cognitive and cellular neuroscience’. PMID:27574312

  10. Prognostic value of exercise pulmonary haemodynamics in pulmonary arterial hypertension.

    PubMed

    Chaouat, Ari; Sitbon, Olivier; Mercy, Magalie; Ponçot-Mongars, Raphaëlle; Provencher, Steeve; Guillaumot, Anne; Gomez, Emmanuel; Selton-Suty, Christine; Malvestio, Pascale; Regent, Denis; Paris, Christophe; Hervé, Philippe; Chabot, François

    2014-09-01

    The aim of the study was to investigate the prognostic value of right heart catheterisation variables measured during exercise. 55 incident patients with idiopathic, familial or anorexigen-associated pulmonary arterial hypertension (PAH) underwent right heart catheterisation at rest and during exercise and 6-min walk testing before PAH treatment initiation. Patients were treated according to recommendations within the next 2 weeks. Right heart catheterisation was repeated 3-5 months into the PAH treatment in 20 patients. Exercise cardiac index decreased gradually as New York Heart Association (NYHA) functional class increased whereas cardiac index at rest was not significantly different across NYHA groups. Baseline 6-min walk distance correlated significantly with exercise and change in cardiac index from rest to exercise (r=0.414 and r=0.481, respectively; p<0.01). Change in 6-min walk distance from baseline to 3-5 months under PAH treatment was highly correlated with change in exercise cardiac index (r=0.746, p<0.001). The most significant baseline covariates associated with survival were change in systolic pulmonary artery pressure from rest to exercise and exercise cardiac index (hazard ratio 0.56 (95% CI 0.37-0.86) and 0.14 (95% CI 0.05-0.43), respectively). Change in pulmonary haemodynamics during exercise is an important tool for assessing disease severity and may help devise optimal treat-to-target strategies. ©ERS 2014.

  11. Effects of systolic anterior motion of the mitral valve on haemodynamics. Evaluation by a direct method.

    PubMed

    Kaku, T; Sakurai, S; Furuno, Y; Yashiro, A; Nakashima, Y; Kuroiwa, A

    1995-08-01

    We evaluated the effects of systolic anterior motion systolic anterior motion of the mitral valve on cardiac haemodynamics. Seven adult mongrel dogs in which systolic anterior motion-septal contact was observed after dobutamine administration were used. To exclude the effects of left ventricular function and morphology, a stone removal basket catheter was placed in the left ventricular outflow tract, and haemodynamics were compared with the basket closed and opened. The basket was opened five times in three dogs not showing systolic anterior motion-septal contact, but the basket itself did not effect the haemodynamics. In the seven dogs that showed systolic anterior motion-septal contact without left ventricular hypertrophy, the basket was opened a total of 33 times in the presence of various degrees of systolic anterior motion-septal contact. After opening the basket, systolic anterior motion was reduced echocardiographically, and significant (P<0.01) changes were observed in the left ventricle-aorta pressure gradient (from 68 +/- 22 to 25 +/- 15 mm Hg), the systolic ejection period (from 146 +/- 19 to 135 +/- 16 ms), and the stroke volume (SV; from 9.4 +/- 2.9 to 10.1 +/- 3.3 ml). After basket inflation, aortic pressure and aortic flow waveforms changed but the peak pressure and flow velocity did not. The temporal distribution of left ventricular ejection also definitely changed after the basket was opened. No changes were observed in the peak dp/dt, peak negative dp/dt, time constant, left ventricular end-diastolic pressure, or left atrial pressure. These observations in this animal model of systolic anterior motion without left ventricular hypertrophy suggest that: (1) there is no potential for generation of an intra-cavity gradient in the absence of systolic anterior motion of the mitral valve, so that (2) systolic anterior motion narrowed the left ventricular outflow tract and, consequently, produced the systolic ejection period, and affected the left

  12. Effects of continuous haemofiltration on serum enzyme concentrations, endotoxemia, homeostasis and survival in dogs with severe heat stroke.

    PubMed

    Chen, Guang-ming; Xu, Hui-na; Gao, Li-fang; Lu, Jin-fu; Wang, Wen-rui; Chen, Jian

    2012-05-01

    To examine the effectiveness of continuous haemofiltration as a treatment for severe heat stroke in dogs. Dogs were randomly allocated to a control or continuous haemofiltration group (both n=8). Heat stroke was induced by placing anaesthetised dogs in a high temperature cabin simulator. Upon confirmation of heat stroke (rectal temperature>42 °C, mean arterial pressure (MAP) decrease>25 mmHg), dogs were removed from the chamber and continuous haemofiltration was initiated and continued for 3h for dogs in the continuous haemofiltration group. Dogs in the control group were observed at room temperature. Rectal temperature, haemodynamics, pH, blood gases and electrolyte concentrations rapidly returned to baseline in the continuous haemofiltration group, but not the control group. After 3h, rectal temperature was 36.68±0.51 °C in the continuous haemofiltration group and 39.83±1.10 °C in the control group (P<0.05). Continuous haemofiltration prevented endotoxin and all serum enzyme concentrations from increasing and caused malondialdehyde concentrations to decrease. After 3h, endotoxin concentrations were 0.14±0.02 EU ml(-1) in the continuous haemofiltration group and 0.23±0.05 EU ml(-1) in the control group (P=0.003), while malondialdehyde concentrations were 4.86±0.61 mmol l(-1) in the continuous haemofiltration group and 8.63±0.66 mmol l(-1) in the control group (P<0.001). Five dogs died in the control group within 3h, whereas no dogs died in the continuous haemofiltration group. Continuous haemofiltration rapidly reduced body temperature, normalised haemodynamics and electrolytes, improved serum enzyme concentrations and increased survival in dogs with heat stroke. Continuous haemofiltration may be an effective treatment for heat stroke. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Interaction between left ventricular twist mechanics and arterial haemodynamics during localised, non-metabolic hyperaemia with and without blood flow restriction.

    PubMed

    van Mil, Anke C C M; Pearson, James; Drane, Aimee L; Cockcroft, John R; McDonnell, Barry J; Stöhr, Eric J

    2016-04-01

    What is the central question of this study? Left ventricular (LV) twist is reduced when afterload is increased, but the meaning of this specific heart muscle response and its impact on cardiac output are not well understood. What is the main finding and its importance? This study shows that LV twist responds even when arterial haemodynamics are altered only locally, and without apparent change in metabolic (i.e. heat-induced) demand. The concurrent decline in cardiac output and LV twist during partial arterial occlusion despite the increased peripheral demand caused by heat stress suggests that LV twist may be involved in the protective sensing of heart muscle stress that can override the provision of the required cardiac output. Whether left ventricular (LV) twist and untwisting rate (LV twist mechanics) respond to localised, peripheral, non-metabolic changes in arterial haemodynamics within an individual's normal afterload range is presently unknown. Furthermore, previous studies indicate that LV twist mechanics may override the provision of cardiac output, but this hypothesis has not been examined purposefully. Therefore, we acutely altered local peripheral arterial haemodynamics in 11 healthy humans (women/men n = 3/8; age 26 ± 5 years) by bilateral arm heating (BAH). Ultrasonography was used to examine arterial haemodynamics, LV twist mechanics and the twist-to-shortening ratio (TSR). To determine the arterial function-dependent contribution of LV twist mechanics to cardiac output, partial blood flow restriction to the arms was applied during BAH (BAHBFR ). Bilateral arm heating increased arm skin temperatures [change (Δ) +6.4 ± 0.9°C, P < 0.0001] but not core temperature (Δ -0.0 ± 0.1°C, P > 0.05), concomitant to increases in brachial artery blood flow (Δ 212 ± 77 ml, P < 0.0001), cardiac output (Δ 495 ± 487 l min(-1) , P < 0.05), LV twist (Δ 3.0 ± 3.5 deg, P < 0.05) and TSR (Δ 3.3 ± 1.3, P < 0.05) but

  14. ISES Training Class - Continuous Measurements

    EPA Science Inventory

    Features of Continuous Monitoring•Provides for high definition of temporal resolution•Provides means for discerning primary exposure events•Provides means for critically examining data quality rather than just an average point•Applicable to any measure of inte...

  15. Acute effects of the combination of sildenafil and inhaled treprostinil on haemodynamics and gas exchange in pulmonary hypertension.

    PubMed

    Voswinckel, Robert; Reichenberger, Frank; Enke, Beate; Kreckel, Andre; Krick, Stefanie; Gall, Henning; Schermuly, Ralph Theo; Grimminger, Friedrich; Rubin, Lewis J; Olschewski, Horst; Seeger, Werner; Ghofrani, Hossein A

    2008-10-01

    Inhaled treprostinil was recently developed for the treatment of pulmonary arterial hypertension (PAH). We investigated the safety and acute haemodynamic effects of the combination oral sildenafil and inhaled treprostinil in an open label study in patients with precapillary pulmonary hypertension. Inhaled nitric oxide (20ppm; n=50), sildenafil (50mg; n=50) and inhaled treprostinil (15microg; n=25 or 30microg; n=25) were applied in subsequent order during right heart catheter investigation to consecutive patients with pulmonary arterial hypertension (PAH; n=28), non-operable chronic thromboembolic pulmonary hypertension (CTEPH; n=17) and pulmonary fibrosis associated pulmonary hypertension (n=5). Inhaled nitric oxide reduced pulmonary vascular resistance (PVR) to 87.3+/-5.1% of baseline values, reduced mean pulmonary arterial pressure (PAP) to 89.7+/-3.5% and increased cardiac output (CO) to 102.4+/-2.9%. Sildenafil reduced PVR to 80.1+/-5.0%, mPAP to 86.5+/-2.9% and increased CO to 103.8+/-3.2%. Treprostinil, inhaled 1h after sildenafil, reduced PVR to 66.3+/-3.8%, mPAP to 77.8+/-3.3%, and increased CO to 107.1+/-3.3% (mean+/-95% confidence interval). Subgroup analysis showed similar acute haemodynamic effects in PAH and CTEPH patients. Ventilation/perfusion distribution measurement in six patients with pre-existing gas exchange limitations was not changed by sildenafil and treprostinil. Relevant side effects were not observed. The combination of sildenafil and inhaled treprostinil was well tolerated and induced additive, pulmonary selective vasodilatation in pulmonary hypertension patients. This could be of relevance also for long-term treatment of PAH and CTEPH patients.

  16. Non-invasive evaluation of the haemodynamic effects of high-dose medetomidine in healthy cats for semen collection.

    PubMed

    Romagnoli, Noemi; Zambelli, Daniele; Cunto, Marco; Lambertini, Carlotta; Ventrella, Domenico; Baron Toaldo, Marco

    2016-04-01

    This study aimed to assess non-invasively the cardiovascular effects of high-dose medetomidine on healthy male cats undergoing semen collection. Haemodynamic evaluations were assessed on the basis of clinical examination, systolic arterial pressure (SAP) and transthoracic echocardiographic examination. Eight client owned, male domestic shorthair cats were sedated with a bolus of medetomidine intramuscularly (IM; 0.13 mg/kg), and semen collection was performed. A second transthoracic echocardiographic examination and SAP measurement were carried out 15 mins after sedation. At the end of the examination, the patients received a bolus of atipamezole (0.3 mg/kg) IM. The cats were deeply sedated, relaxed and laterally recumbent during the entire procedure. No rhythm abnormalities were observed during the examinations and no significant increase in SAP was recorded. Heart rate dropped from 200 ± 33 to 92 ± 13.1 beats per min after sedation. There was a significant increase in left ventricular dimensions and the left atrial area. The parameters of left ventricular systolic function were reduced, as were systemic and pulmonary cardiac outputs. Peak diastolic wave velocities were significantly reduced, while isovolumic contraction and relaxation time of the left ventricle were prolonged. Aortic valve insufficiency was recorded for all cats, while mitral valve insufficiency was noted in five cats. None of the subjects developed systolic anterior motion of the mitral valve. The protocol allowed us to collect good semen samples in healthy cats. However, high-dose medetomidine induces significant haemodynamic effects on the feline heart, mainly due to a reduced heart rate, an increased cardiac preload and impaired systolic function. The animals recovered from the anaesthesia, after antagonist administration, without showing any clinically relevant consequences. © ISFM and AAFP 2015.

  17. Exercise performance, haemodynamics, and respiratory pattern do not identify heart failure patients who end exercise with dyspnoea from those with fatigue.

    PubMed

    Morosin, Marco; Farina, Stefania; Vignati, Carlo; Spadafora, Emanuele; Sciomer, Susanna; Salvioni, Elisabetta; Sinagra, Gianfranco; Agostoni, Piergiuseppe

    2018-02-01

    The two main symptoms referred by chronic heart failure (HF) patients as the causes of exercise termination during maximal cardiopulmonary exercise testing (CPET) are muscular fatigue and dyspnoea. So far, a physiological explanation why some HF patients end exercise because of dyspnoea and others because of fatigue is not available. We assessed whether patients referring dyspnoea or muscular fatigue may be distinguished by different ventilator or haemodynamic behaviours during exercise. We analysed exercise data of 170 consecutive HF patients with reduced left ventricular ejection fraction in stable clinical condition. All patients underwent maximal CPET and a second maximal CPET with measurement of cardiac output by inert gas rebreathing at peak exercise. Thirty-eight (age 65.0 ± 11.1 years) and 132 (65.1 ± 11.4 years) patients terminated CPET because of dyspnoea and fatigue, respectively. Haemodynamic and cardiorespiratory parameters were the same in fatigue and dyspnoea patients. VO 2 was 10.4 ± 3.2 and 10.5 ± 3.3 mL/min/kg at the anaerobic threshold and 15.5 ± 4.8 and 15.4 ± 4.3 at peak, in fatigue and dyspnoea patients, respectively. In fatigue and dyspnoea patients, peak heart rate was 110 ± 22 and 114 ± 22 beats/min, and VE/VCO 2 and VO 2 /work relationship slopes were 31.2 ± 6.8 and 30.6 ± 8.2 and 10.6 ± 4.2 and 11.4 ± 5.5 L/min/W, respectively. Peak cardiac output was 6.68 ± 2.51 and 6.21 ± 2.55 L/min (P = NS for all). In chronic HF patients in stable clinical condition, fatigue and dyspnoea as reasons of exercise termination do not highlight different ventilatory or haemodynamic patterns during effort. © 2017 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiology.

  18. Laparoscopic management of retroperitoneal injuries from penetrating abdominal trauma in haemodynamically stable patients.

    PubMed

    Koto, Modise Zacharia; Matsevych, Oleh Y; Mosai, Fusi; Balabyeki, Moses; Aldous, Colleen

    2018-02-27

    Laparoscopy is increasingly utilised in the trauma setting. However, its safety and reliability in evaluating and managing retroperitoneal injuries are not known. The aim of this study was to analyse our experience with laparoscopic management of retroperitoneal injuries due to penetrating abdominal trauma (PAT) and to investigate its feasibility, safety and accuracy in haemodynamically stable patients. Over a 4-year period, patients approached laparoscopically with retroperitoneal injuries were analysed. Mechanism, location and severity of injuries were recorded. Surgical procedures, conversion rate and reasons for conversion and outcomes were described. Of the 284 patients with PAT, 56 patients had involvement of retroperitoneum. Stab wounds accounted 62.5% of patients. The mean Injury Severity Score was 7.4 (4-20). Among retroperitoneal injuries, the colon (27%) was the most commonly involved hollow viscera followed by duodenum (5%). The kidney (5%) and the pancreas (4%) were the injured solid organs. The conversion rate was 19.6% and was mainly due to active bleeding (73%). Significantly more patients with gunshot wound were converted to laparotomy (38% vs. 9%). Therapeutic laparoscopy was performed in 36% of patients. There were no recorded missed injuries or mortality. Five (9%) patients developed the Clavien-Dindo Grade 3 complications, three were managed with reoperation, one with drainage/debridement and one with endovascular technique. Laparoscopic management of retroperitoneal injuries is safe and feasible in haemodynamically stable patients with PAT. However, a high conversion rate indicates difficulties in managing these injuries. The requirements are the dexterity in laparoscopy and readiness to convert in the event of bleeding.

  19. [The effects of perioperative continuous administration of mivazerol on early postoperative hemodynamics and plasma catecholamines after major surgery].

    PubMed

    Apitzsch, H; Olthoff, D; Thieme, V; Vetter, B; Wiegel, M

    2000-08-01

    During and after surgical procedures a strong activation of the sympatho-adrenergic system is common with correlation to adverse cardiac outcome. Several drugs (alpha 2-adrenoceptor-agonists, beta blockers) are discussed to prevent this reaction. The new alpha 2-adrenoceptor-agonist mivazerol with marked specificity for alpha 2-adrenergic receptors may be suitable for this indication. The aim of the present study was to investigate the effects of perioperative continuous administration of mivazerol on plasma catecholamines, body temperature and calculated haemodynamic parameters in the early postoperative period in cardiac risk patients undergoing non-cardiac surgery. 36 patients with known coronary heart disease or risk factors for coronary heart disease scheduled for elective abdominal or vascular surgery were included in the study. Patients received either mivazerol (n = 18) or placebo (n = 18) [initial dose 4 micrograms kg-1 for 10 minutes before induction of anaesthesia, followed by a continuous infusion of 1.5 micrograms kg-1 h-1 intraoperatively and for as long as 72 h after surgery] in a double-blinded, randomized manner. Blood pressure, heart rate and body temperature were measured every 10 minutes until 240 minutes after arrival at the ICU. During 240 minutes after arrival at the ICU measured parameters (CVP, PAP, PCWP, SaO2, SvO2, CO), calculated parameters (CI, SVR, PVR, VO2) and plasma catecholamines were measured at defined time intervalls. The plasma concentrations of epinephrine and norepinephrine and the heart rate were significantly lower in the mivazerol group in the study period. Regarding blood pressure and body temperature there were no differences between the groups. At some measuring points preload was higher in the mivazerol group, but there were no differences between the groups for measured (SaO2, SvO2, CO) and calculated (CI, SVR, PVR, VO2) cardiorespiratory parameters. The incidence of shivering, nausea and vomiting were similar in both

  20. pyNS: an open-source framework for 0D haemodynamic modelling.

    PubMed

    Manini, Simone; Antiga, Luca; Botti, Lorenzo; Remuzzi, Andrea

    2015-06-01

    A number of computational approaches have been proposed for the simulation of haemodynamics and vascular wall dynamics in complex vascular networks. Among them, 0D pulse wave propagation methods allow to efficiently model flow and pressure distributions and wall displacements throughout vascular networks at low computational costs. Although several techniques are documented in literature, the availability of open-source computational tools is still limited. We here present python Network Solver, a modular solver framework for 0D problems released under a BSD license as part of the archToolkit ( http://archtk.github.com ). As an application, we describe patient-specific models of the systemic circulation and detailed upper extremity for use in the prediction of maturation after surgical creation of vascular access for haemodialysis.

  1. Amiodarone. Haemodynamic profile during intravenous administration and effect on pacing-induced ischaemia in man.

    PubMed

    Remme, W J; van Hoogenhuyze, D C; Kruyssen, D A; Krauss, X H; Storm, C J

    1985-03-01

    The haemodynamic changes during intravenous amiodarone administration in laboratory animals and human studies are reviewed and compared with the results from our investigations. While the results of previous human studies have been rather variable, our investigations suggest that the cardiovascular changes following intravenous amiodarone include an early and usually short reduction of systemic and coronary vascular resistance, which may be partially due to the vasodilating properties of the solvent, polysorbate 80. As a result, a decrease in afterload and cardiac work and increases in cardiac output and coronary blood flow occur. Contrary to the observations in the animal experiments, heart rate increases in man, presumably as a result of the relatively greater fall in afterload which occurs. However, in spite of this increase in heart rate, contractility is reduced at the end of amiodarone administration and remains depressed after the infusion, resulting in a significant increase in left ventricular filling pressure. Neither myocardial oxygen demand nor consumption change during amiodarone administration. Although the intrinsic negative inotropic effects of amiodarone warrant a cautious approach in patients with left ventricular dysfunction, worsening of heart failure or the occurrence of myocardial ischaemia has been reported in only very few cases so far. In contrast, the drug was demonstrated to protect against pacing-induced myocardial ischaemia, in patients with both normal and depressed left ventricular function. These anti-ischaemic properties of amiodarone were investigated in a second study using a double pacing stress test protocol. Overall myocardial oxygen consumption did not change during pacing after amiodarone, but it clearly reduced (regional) myocardial ischaemia, as demonstrated by a reduction of ST-segment changes and anginal pain, and in particular by the absence of myocardial lactate production during pacing after amiodarone. These anti

  2. Continual Response Measurement: Design and Validation.

    ERIC Educational Resources Information Center

    Baggaley, Jon

    1987-01-01

    Discusses reliability and validity of continual response measurement (CRM), a computer-based measurement technique, and its use in social science research. Highlights include the importance of criterion-referencing the data, guidelines for designing studies using CRM, examples typifying their deductive and inductive functions, and a discussion of…

  3. Haemodynamic changes in ipsilateral and contralateral fingers caused by acute exposures to hand transmitted vibration.

    PubMed Central

    Bovenzi, M; Griffin, M J

    1997-01-01

    OBJECTIVES: To investigate changes in digital circulation during and after exposure to hand transmitted vibration. By studying two frequencies and two magnitudes of vibration, to investigate the extent to which haemodynamic changes depend on the vibration frequency, the vibration acceleration, and the vibration velocity. METHODS: Finger skin temperature (FST), finger blood flow (FBF), and finger systolic pressure were measured in the fingers of both hands in eight healthy men. Indices of digital vasomotor tone-such as critical closing pressure and vascular resistance-were estimated by pressure-flow curves obtained with different hand heights. With a static load of 10 N, the right hand was exposed for 30 minutes to each of the following root mean squared (rms) acceleration magnitudes and frequencies of vertical vibration: 22 m.s-2 at 31.5 Hz, 22 m.s-2 at 125 Hz, and 87 m.s-2 at 125 Hz. A control condition consisted of exposure to the static load only. The measures of digital circulation and vasomotor tone were taken before exposure to the vibration and the static load, and at 0, 20, 40, and 60 minutes after the end of each exposure. RESULTS: Exposure to static load caused no significant changes in FST, FBF, or indices of vasomotor tone in either the vibrated right middle finger or the non-vibrated left middle finger. In both fingers, exposure to vibration of 125 Hz and 22 m.s-2 produced a greater reduction in FBF and a greater increase in vasomotor tone than did vibration of 31.5 Hz and 22 m.s-2. In the vibrated right finger, exposure to vibration of 125 Hz and 87 m.s-2 provoked an immediate vasodilation which was followed by vasoconstriction during recovery. The non-vibrated left finger showed a significant increase in vasomotor tone throughout the 60 minute period after the end of vibration exposure. CONCLUSIONS: The digital circulatory response to acute vibration depends upon the magnitude and frequency of the vibration stimulus. Vasomotor mechanisms, mediated

  4. Acute effects of 3G mobile phone radiations on frontal haemodynamics during a cognitive task in teenagers and possible protective value of Om chanting.

    PubMed

    Bhargav, Hemant; N K, Manjunath; Varambally, Shivarama; Mooventhan, A; Bista, Suman; Singh, Deepeshwar; Chhabra, Harleen; Venkatasubramanian, Ganesan; T M, Srinivasan; H R, Nagendra

    2016-06-01

    Mobile phone induced electromagnetic field (MPEMF) as well as chanting of Vedic mantra 'OM' has been shown to affect cognition and brain haemodynamics, but findings are still inconclusive. Twenty right-handed healthy teenagers (eight males and 12 females) in the age range of 18.25 ± 0.44 years were randomly divided into four groups: (1) MPONOM (mobile phone 'ON' followed by 'OM' chanting); (2) MPOFOM (mobile phone 'OFF' followed by 'OM' chanting); (3) MPONSS (mobile phone 'ON' followed by 'SS' chanting); and (4) MPOFSS (mobile phone 'OFF' followed by 'SS' chanting). Brain haemodynamics during Stroop task were recorded using a 64-channel fNIRS device at three points of time: (1) baseline, (2) after 30 min of MPON/OF exposure, and (3) after 5 min of OM/SS chanting. RM-ANOVA was applied to perform within- and between-group comparisons, respectively. Between-group analysis revealed that total scores on incongruent Stroop task were significantly better after OM as compared to SS chanting (MPOFOM vs MPOFSS), pre-frontal activation was significantly lesser after OM as compared to SS chanting in channel 13. There was no significant difference between MPON and MPOF conditions for Stroop performance, as well as brain haemodynamics. These findings need confirmation through a larger trial in future.

  5. Discrete photon statistics from continuous microwave measurements

    NASA Astrophysics Data System (ADS)

    Virally, Stéphane; Simoneau, Jean Olivier; Lupien, Christian; Reulet, Bertrand

    2016-04-01

    Photocount statistics are an important tool for the characterization of electromagnetic fields, especially for fields with an irrelevant phase. In the microwave domain, continuous rather than discrete measurements are the norm. Using a different approach, we recover discrete photon statistics from the cumulants of a continuous distribution of field quadrature measurements. The use of cumulants allows the separation between the signal of interest and experimental noise. Using a parametric amplifier as the first stage of the amplification chain, we extract useful data from up to the sixth cumulant of the continuous distribution of a coherent field, hence recovering up to the third moment of the discrete statistics associated with a signal with much less than one average photon.

  6. Relationship between exercise pressure gradient and haemodynamic progression of aortic stenosis.

    PubMed

    Ringle, Anne; Levy, Franck; Ennezat, Pierre-Vladimir; Le Goffic, Caroline; Castel, Anne-Laure; Delelis, François; Menet, Aymeric; Malaquin, Dorothée; Graux, Pierre; Vincentelli, André; Tribouilloy, Christophe; Maréchaux, Sylvestre

    We hypothesized that large exercise-induced increases in aortic mean pressure gradient can predict haemodynamic progression during follow-up in asymptomatic patients with aortic stenosis. We retrospectively identified patients with asymptomatic moderate or severe aortic stenosis (aortic valve area<1.5cm 2 or<1cm 2 ) and normal ejection fraction, who underwent an exercise stress echocardiography at baseline with a normal exercise test and a resting echocardiography during follow-up. The relationship between exercise-induced increase in aortic mean pressure gradient and annualised changes in resting mean pressure gradient during follow-up was investigated. Fifty-five patients (mean age 66±15 years; 45% severe aortic stenosis) were included. Aortic mean pressure gradient significantly increased from rest to peak exercise (P<0.001). During a median follow-up of 1.6 [1.1-3.2] years, resting mean pressure gradient increased from 35±13mmHg to 48±16mmHg, P<0.0001. Median annualised change in resting mean pressure gradient during follow-up was 5 [2-11] mmHg. Exercise-induced increase in aortic mean pressure gradient did correlate with annualised changes in mean pressure gradient during follow-up (r=0.35, P=0.01). Hemodynamic progression of aortic stenosis was faster in patients with large exercise-induced increase in aortic mean pressure gradient (≥20mmHg) as compared to those with exercise-induced increase in aortic mean pressure gradient<20mmHg (median annualised increase in mean pressure gradient 19 [6-28] vs. 4 [2-10] mmHg/y respectively, P=0.002). Similar results were found in the subgroup of 30 patients with moderate aortic stenosis. Large exercise-induced increases in aortic mean pressure gradient correlate with haemodynamic progression of stenosis during follow-up in patients with asymptomatic aortic stenosis. Further studies are needed to fully establish the role of ESE in the decision-making process in comparison to other prognostic markers in asymptomatic

  7. Chest shielding for prevention of a haemodynamically significant patent ductus arteriosus in preterm infants receiving phototherapy.

    PubMed

    Bhola, Kavita; Foster, Jann P; Osborn, David A

    2015-11-03

    Patent ductus arteriosus (PDA) is associated with mortality and morbidity in preterm infants. Phototherapy is a common treatment for jaundice in preterm infants. However, phototherapy has been associated with failure of closure of the ductus arteriosus in preterm infants. To determine if chest shielding of preterm infants receiving phototherapy reduces the incidence of clinically and/or haemodynamically significant PDA and reduces morbidity secondary to PDA. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library; 2015, Issue 3), MEDLINE, EMBASE, CINAHL, previous reviews, cross-references, abstracts, proceedings of scientific meetings, and trial registries through March 2015. Randomised controlled trials (RCTs), cluster-RCTs, or quasi-RCTs of chest shielding during phototherapy compared to sham shielding or no shielding for the prevention of a haemodynamically or clinically significant PDA in preterm infants. Three review authors independently assessed studies for eligibility and quality and extracted data. We defined a clinically significant PDA as the presence of a PDA with clinical signs of an effect on organ function attributable to the ductus arteriosus. We defined a haemodynamically significant PDA as clinical and/or echocardiographic signs of a significant ductus arteriosus effect on blood flow. We included two small trials enrolling very preterm infants (Rosenfeld 1986; Travadi 2006). We assessed both as at high risk of bias. No study reported clinically significant PDA, defined as the presence of a PDA with clinical symptoms or signs attributable to the effect of a ductus arteriosus on organ function. Rosenfeld 1986 reported a non-significant reduction in haemodynamically significant PDA with left atrial to aortic root ratio greater than 1.2 (risk ratio (RR) 0.23, 95% confidence interval (CI) 0.05 to 1.01; 74 infants) but a statistically significant risk difference (RD -0.18, 95% CI -0.34 to -0.03; number needed to

  8. The haemodynamic effects of intravenous paracetamol (acetaminophen) in healthy volunteers: a double‐blind, randomized, triple crossover trial

    PubMed Central

    Chiam, Elizabeth; Bailey, Michael; McNicol, Larry; Bellomo, Rinaldo

    2016-01-01

    Aim The haemodynamic effects of intravenous paracetamol have not been systematically investigated. We compared the physiological effects of intravenous mannitol‐containing paracetamol, and an equivalent dosage of mannitol, and normal saline 0.9% in healthy volunteers. Methods We performed a blinded, triple crossover, randomized trial of 24 adult healthy volunteers. Participants received i.v. paracetamol (1 g paracetamol +3.91 g mannitol 100 ml–1), i.v. mannitol (3.91 g mannitol 100 ml–1) and i.v. normal saline (100 ml). Composite primary end points were changes in mean arterial pressure (MAP), systolic blood pressure (SBP) and diastolic blood pressure (DBP) measured pre‐infusion, during a 15 min infusion period and over a 45 min observation period. Systemic vascular resistance index (SVRI) and cardiac index were measured at the same time points. Results Infusion of paracetamol induced a transient yet significant decrease in blood pressures from pre‐infusion values (MAP –1.85 mmHg, 95% CI –2.6, –1.1, SBP –0.54 mmHg, 95% CI –1.7, 0.6 and DBP −1.92 mmHg, 95% CI –2.6, –1.2, P < 0.0001), associated with a transient reduction in SVRI and an increase in cardiac index. Changes were observed, but to a lesser extent with normal saline (MAP –0.15 mmHg, SBP +1.44 mmHg, DBP −–0.73 mmHg, P < 0.0001), but not with mannitol (MAP +1.47 mmHg, SBP +4.03 mmHg, DBP +0.48 mmHg, P < 0.0001). Conclusions I.v. paracetamol caused a transient decrease in blood pressure immediately after infusion. These effects were not seen with mannitol or normal saline. The physiological mechanism was consistent with vasodilatation. This study provides plausible physiological data in a healthy volunteer setting, supporting transient changes in haemodynamic variables with i.v. paracetamol and justifies controlled studies in the peri‐operative and critical care setting. PMID:26606263

  9. Venous haemodynamics of Jet Impulse Technology within a lower limb fibreglass cast: a randomized controlled trial

    PubMed Central

    Mackintosh, Stephen; Buchanan, Samantha; Schwarzenlander, Kerstin; De Ruyter, Bernadette

    2017-01-01

    Objectives We investigated popliteal venous haemodynamics of the VenaJet Jet Impulse Technology system within a below-knee fibreglass cast. Design Randomized controlled trial. Participants Twenty-four healthy participants aged 18–54 had both feet placed within the Jet Impulse Technology system and were randomised for one or other leg to be within a below-knee fibreglass cast. Setting Pacific Radiology, Lower Hutt, Wellington Main outcome measures The primary outcome variable was peak systolic velocity (cm/s) compared between legs with and without the cast at 60 min (after 10 min Jet Impulse Technology activation), using a mixed linear model and a non-inferiority bound of 4.8 cm/s. Secondary outcome variables were the difference in peak systolic velocity between the casted limb and the non-casted limb at baseline and 40 min after casting, and the difference in mean flow velocity (cm/s), vein diameter (mm), and total volume flow (L/min) between the casted limb and the non-casted limb at baseline, 40 and 60 min. Results The mean (standard deviation) peak systolic velocity was 4.6(1.5), 4.8(1.1), 28.8(16.1), and 4.3(1.2), 4.8(1.4) and 29.3(19.0) cm/s at baseline, 40 and 60 min in the casted and non-casted leg, respectively. The difference (95% confidence interval) between cast and no-cast at 60 min was −0.8 (−6.5 to 4.9) cm/s, P = 0.78. The peak systolic velocity, flow velocity and total volume flow at 40 min were not statistically significantly different from baseline for both casted and non-casted limb. Conclusion In healthy volunteers, the popliteal venous haemodynamics of the Jet Impulse Technology system was similar between the legs with and without a below-knee fibreglass cast. In-cast Jet Impulse Technology may provide a non-pharmacological option for venous thromboembolism prophylaxis for lower-limb cast-immobility. PMID:28203384

  10. Effect of whole-body mild-cold exposure on arterial stiffness and central haemodynamics: a randomised, cross-over trial in healthy men and women.

    PubMed

    King, Sibella G; Ahuja, Kiran D K; Wass, Jezreel; Shing, Cecilia M; Adams, Murray J; Davies, Justin E; Sharman, James E; Williams, Andrew D

    2013-05-01

    Aortic pulse wave velocity (PWV) and augmentation index (AIx) are independent predictors of cardiovascular risk and mortality, but little is known about the effect of air temperature changes on these variables. Our study investigated the effect of exposure to whole-body mild-cold on measures of arterial stiffness (aortic and brachial PWV), and on central haemodynamics [including augmented pressure (AP), AIx], and aortic reservoir components [including reservoir and excess pressures (P ex)]. Sixteen healthy volunteers (10 men, age 43 ± 19 years; mean ± SD) were randomised to be studied under conditions of 12 °C (mild-cold) and 21 °C (control) on separate days. Supine resting measures were taken at baseline (ambient temperature) and after 10, 30, and 60 min exposure to each experimental condition in a climate chamber. There was no significant change in brachial blood pressure between mild-cold and control conditions. However, compared to control, AP [+2 mmHg, 95 % confidence interval (CI) 0.36-4.36; p = 0.01] and AIx (+6 %, 95 % CI 1.24-10.1; p = 0.02) increased, and time to maximum P ex (a component of reservoir function related to timing of peak aortic in-flow) decreased (-7 ms, 95 % CI -15.4 to 2.03; p = 0.01) compared to control. Yet there was no significant change in aortic PWV (+0.04 m/s, 95 % CI -0.47 to 0.55; p = 0.87) or brachial PWV (+0.36 m/s; -0.41 to 1.12; p = 0.35) between conditions. We conclude that mild-cold exposure increases central haemodynamic stress and alters timing of peak aortic in-flow without differentially affecting arterial stiffness.

  11. Deceleration time of left ventricular outflow tract flow as a simple surrogate marker for central haemodynamics at rest and as well as during exercise.

    PubMed

    Cho, In-Jeong; Shim, Chi Young; Moon, Sun-Ha; Lee, Hyun-Jin; Hong, Geu-Ru; Chung, Namsik; Ha, Jong-Won

    2017-05-01

    The shape and duration of left ventricular outflow tract (LVOT) flow has not been applied to assess the central haemodynamics, although LVOT flow is confronted with afterload of arterial system during systole. The aim of this study was to evaluate whether the LVOT flow parameters are related with central systolic blood pressure (BP) and arterial compliance at rest and as well as during exercise. We studied 258 subjects (175 females, age 61 ± 11 years) with normal left ventricular (LV) systolic function who underwent supine bicycle stress echocardiography and arterial tonometry simultaneously at rest and at peak exercise. Deceleration time (DT) of LVOT flow and RR interval were measured and deceleration time corrected for heart rate (DTc) was calculated. Peripheral and central haemodynamic parameters including systolic and diastolic BP, and augmentation index at a heart rate of 75 (AIx@75) were assessed using radial artery tonometry. Carotid femoral pulse wave velocity (PWV) was measured. Deceleration time corrected for heart rate was independently associated with central systolic BP and AIx@75 at rest (P < 0.001 and 0.006). Similarly, it also showed significant independent correlations with central systolic BP and AIx@75 during peak exercise (P = 0.006 and P = 0.021). In addition, DTc which measured both at rest and at peak exercise demonstrated significant positive correlations with PWV, suggesting association of prolonged DTc with arterial stiffening (P = 0.023 and P = 0.005). Prolongation of LVOT flow DTc represents raised central systolic BP and increased arterial stiffness not only at rest but also during exercise. Therefore, central aortic pressures and arterial stiffness influence the DT of LVOT flow at rest as well as during exercise in individuals with normal LV systolic function. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  12. Assessment of an updated double-vasopressor automated system using Nexfin for the maintenance of haemodynamic stability to improve peri-operative outcome during spinal anaesthesia for caesarean section.

    PubMed

    Sng, B L; Wang, H; Assam, P N; Sia, A T

    2015-06-01

    Hypotension occurs commonly during spinal anaesthesia for caesarean section, associated with maternal and fetal adverse effects. We developed a double-vasopressor automated system with a two-step algorithm and continuous non-invasive haemodynamic monitoring using the Nexfin device. The system delivered 25 μg phenylephrine every 30 s when systolic blood pressure was between 90% and 100% of baseline, or 2 mg ephedrine at this blood pressure range and heart rate < 60 beats.min(-1) ; and 50 μg phenylephrine or 4 mg ephedrine when systolic blood pressure was < 90% of baseline with the same heart rate criterion. Fifty-seven women received standardised spinal anaesthesia. Twenty-seven (47.4%) had at least one reading of hypotension defined as systolic blood pressure < 80% baseline. Systolic blood pressure was within 20% of the baseline in a mean (SD) of 79.8 (20.9)% of measurements. Fifty-three (93.0%) women required phenylephrine before delivery while 10 (17.5%) required ephedrine. Six women (10.5%) experienced nausea and three (5.3%) vomited. The system was able to achieve a low incidence of maternal hypotension with good maternal and fetal outcomes. © 2015 The Association of Anaesthetists of Great Britain and Ireland.

  13. Stress-sensitive arterial hypertension, haemodynamic changes and brain metabolites in hypertensive ISIAH rats: MRI investigation.

    PubMed

    Seryapina, A A; Shevelev, O B; Moshkin, M P; Markel, A L; Akulov, A E

    2017-05-01

    What is the central question of this study? Stress-sensitive arterial hypertension is considered to be controlled by changes in central and peripheral sympathetic regulating mechanisms, which eventually result in haemodynamic alterations and blood pressure elevation. Therefore, study of the early stages of development of hypertension is of particular interest, because it helps in understanding the aetiology of the disease. What is the main finding and its importance? Non-invasive in vivo investigation in ISIAH rats demonstrated that establishment of sustainable stress-sensitive hypertension is accompanied by a decrease in prefrontal cortex activity and mobilization of hypothalamic processes, with considerable correlations between haemodynamic parameters and individual metabolite ratios. The study of early development of arterial hypertension in association with emotional stress is of great importance for better understanding of the aetiology and pathogenesis of the hypertensive disease. Magnetic resonance imaging (MRI) was applied to evaluate the changes in haemodynamics and brain metabolites in 1- and 3-month-old inherited stress-induced arterial hypertension (ISIAH) rats (10 male rats) with stress-sensitive arterial hypertension and in control normotensive Wistar Albino Glaxo (WAG) rats (eight male rats). In the 3-month-old ISIAH rats, the age-dependent increase in blood pressure was associated with increased blood flow through the renal arteries and decreased blood flow in the lower part of the abdominal aorta. The renal vascular resistance in the ISIAH rats decreased during ageing, although at both ages it remained higher than the renal vascular resistance in WAG rats. An integral metabolome portrait demonstrated that development of hypertension in the ISIAH rats was associated with an attenuation of the excitatory and energetic activity in the prefrontal cortex, whereas in the WAG rats the opposite age-dependent changes were observed. In contrast, in the

  14. Continuous quantum measurement with independent detector cross correlations.

    PubMed

    Jordan, Andrew N; Büttiker, Markus

    2005-11-25

    We investigate the advantages of using two independent, linear detectors for continuous quantum measurement. For single-shot measurement, the detection process may be quantum limited if the detectors are twins. For weak continuous measurement, cross correlations allow a violation of the Korotkov-Averin bound for the detector's signal-to-noise ratio. The joint weak measurement of noncommuting observables is also investigated, and we find the cross correlation changes sign as a function of frequency, reflecting a crossover from incoherent relaxation to coherent, out of phase oscillations. Our results are applied to a double quantum-dot charge qubit, simultaneously measured by two quantum point contacts.

  15. Measuring continuous baseline covariate imbalances in clinical trial data

    PubMed Central

    Ciolino, Jody D.; Martin, Renee’ H.; Zhao, Wenle; Hill, Michael D.; Jauch, Edward C.; Palesch, Yuko Y.

    2014-01-01

    This paper presents and compares several methods of measuring continuous baseline covariate imbalance in clinical trial data. Simulations illustrate that though the t-test is an inappropriate method of assessing continuous baseline covariate imbalance, the test statistic itself is a robust measure in capturing imbalance in continuous covariate distributions. Guidelines to assess effects of imbalance on bias, type I error rate, and power for hypothesis test for treatment effect on continuous outcomes are presented, and the benefit of covariate-adjusted analysis (ANCOVA) is also illustrated. PMID:21865270

  16. Predicting haemodynamic networks using electrophysiology: The role of non-linear and cross-frequency interactions

    PubMed Central

    Tewarie, P.; Bright, M.G.; Hillebrand, A.; Robson, S.E.; Gascoyne, L.E.; Morris, P.G.; Meier, J.; Van Mieghem, P.; Brookes, M.J.

    2016-01-01

    Understanding the electrophysiological basis of resting state networks (RSNs) in the human brain is a critical step towards elucidating how inter-areal connectivity supports healthy brain function. In recent years, the relationship between RSNs (typically measured using haemodynamic signals) and electrophysiology has been explored using functional Magnetic Resonance Imaging (fMRI) and magnetoencephalography (MEG). Significant progress has been made, with similar spatial structure observable in both modalities. However, there is a pressing need to understand this relationship beyond simple visual similarity of RSN patterns. Here, we introduce a mathematical model to predict fMRI-based RSNs using MEG. Our unique model, based upon a multivariate Taylor series, incorporates both phase and amplitude based MEG connectivity metrics, as well as linear and non-linear interactions within and between neural oscillations measured in multiple frequency bands. We show that including non-linear interactions, multiple frequency bands and cross-frequency terms significantly improves fMRI network prediction. This shows that fMRI connectivity is not only the result of direct electrophysiological connections, but is also driven by the overlap of connectivity profiles between separate regions. Our results indicate that a complete understanding of the electrophysiological basis of RSNs goes beyond simple frequency-specific analysis, and further exploration of non-linear and cross-frequency interactions will shed new light on distributed network connectivity, and its perturbation in pathology. PMID:26827811

  17. Comparison of the Effects of Thiopental Sodium and Propofol on Haemodynamics, Awareness and Newborns During Caesarean Section Under General Anaesthesia.

    PubMed

    Çakırtekin, Vedat; Yıldırım, Ahmet; Bakan, Nurten; Çelebi, Nevin; Bozkurt, Özkan

    2015-04-01

    To compare the effects of propofol and thiopental on haemodynamics, awareness and newborns in pregnant women undergoing elective caesarean section. Seventy pregnant women were assigned into two equal groups. For anaesthesia induction, 2 mg kg(-1) propofol (Group P) and 5 mg kg(-1) thiopental (Group T) were administered. Maternal haemodynamic parameters and bispectral index (BIS) values were recorded before induction, in 1-minute intervals within the first 10 minutes after induction and in 5-minute intervals thereafter, during skin incision, uterine incision, removal of infant, uterine sutures, skin sutures, eye opening and extubation in all cases. Cord blood gas analysis and 1- and 5-minute APGAR scores were recorded. In all cases, a keyword was spelled to ear during removal of the infant, and at the first postoperative hour, patients were questioned. Important time periods of surgery and anaesthesia and also the first postoperative hour haemodynamic values, pain scores, nausea and vomiting were noted. The demographic data were similar among cases. In Group T, systolic arterial pressure (SAP), diastolic arterial pressure (DAP) and mean arterial pressure (MAP) at the first 2 minutes after induction and heart rate (HR) at almost all time points were significantly higher. BIS values from induction to the eighth minute and skin incision, uterine incision and removal of the infant were lower in Group P. No patient remembered the keyword spelled, while 4 patients reported dreaming during general anaesthesia. The effects of propofol and thiopental sodium on 1- and 5-minute APGAR scores, cord blood gas values and postoperative visual analogue scale (VAS) scores were similar. Propofol is a more appropriate anaesthetic agent than thiopental in anaesthesia for caesareans, since it provides better anaesthestic depth and more rapid recovery.

  18. Morphologic characteristics of central pulmonary thromboemboli predict haemodynamic response in massive pulmonary embolism.

    PubMed

    Podbregar, Matej; Voga, Gorazd; Krivec, Bojan

    2004-08-01

    On hospital admission, the morphology of the central pulmonary artery thromboemboli is an independent predictor of 30-day mortality in patients with massive pulmonary embolism (MPE). This may be due to the differential susceptibility of thromboemboli to thrombolysis. The aim of this study was to assess haemodynamic response to treatment in patients with MPE and morphologically different thromboemboli. Prospective observational study. An 11-bed closed medical ICU at a 860-bed community general hospital. Twelve consecutive patients with shock or hypotension due to MPE and central pulmonary thromboemboli detected by transesophageal echocardiography who were treated with thrombolysis between January 2000 through April 2002. Patients were divided into two groups according to the characteristics of detected central pulmonary thromboemboli: group 1, thrombi with one or more long, mobile parts; and group 2, immobile thrombi. Urokinase infusion was terminated when mixed venous oxygen saturation was stabilized above 60% for 15 min. At 2 h, the total pulmonary vascular resistance index was reduced more in group 1 than group 2 [from 27+/-12 mmHg/(l.min.m(2)) to 14+/-6 mmHg/(l.min.m(2)) (-52%) vs 27+/-8 mmHg/(l.min.m(2)) to 23+/-10 mmHg/(l.min.m(2)) (-15%), respectively, P=0.04]. In group 1 thrombolysis was terminated earlier than group 2 (89+/-40 min vs 210+/-62 min, respectively, P= 0.0024). The cumulative dose of urokinase used in group 1 was lower than group 2 (1.7+/-0.3 M i.u. vs 2.7+/-0.5 M i.u., respectively, P= 0.023). Haemodynamic stabilization is achieved faster in patients with mobile central thromboemboli detected by transesophageal echocardiography during MPE.

  19. Haemodynamic stability during general anaesthesia for intra-ocular surgery: the effect of topical oxybuprocaine.

    PubMed

    Lytle, J; Thomas, N F

    1992-07-01

    Local anaesthesia is frequently used in combination with light general anaesthesia to reduce the reflex responses to surgical stimulation. This combination has not previously been evaluated for intra-ocular surgery. During cataract extraction under general anaesthesia, the effect of topical anaesthesia with oxybuprocaine 0.4% on the pressor response was compared with normal saline in a control group. The simple technique of instilling local anaesthetic drops into the conjunctival sac blocked the pain pathway sufficiently to prevent the pressor response to surgical stimulation (p less than 0.001). Higher inspired concentrations of enflurane were required in the control group to achieve and maintain haemodynamic stability (p less than 0.001).

  20. Cold pressor stimulus temperature and resting masseter muscle haemodynamics in normal humans.

    PubMed

    Maekawa, K; Kuboki, T; Clark, G T; Shinoda, M; Yamashita, A

    1998-11-01

    Cold pressor stimulation reportedly increases sympathetic nerve activity in human skeletal muscles. This study examined the effect of cold pressor stimulation on the resting haemodynamics of the right masseter muscle in normal individuals, using near-infrared spectroscopy. Nine healthy non-smoking males with no history of chronic muscle pain or vascular headaches participated. Their right hand was immersed in a water bath (4, 10, 15 degrees C) for exactly 1 min. Each trial lasted 7 min (1 min before, 1 min during, 5 min after stimulation) and a strictly random order was utilized for the three test temperatures and the mock trial. Masseter muscle haemoglobin concentration and oxygen saturation, as well as heart rate and blood pressure, were continuously recorded in each trial. After completing the four trials, each participant produced and sustained a 30-s maximum voluntary clench in the intercuspal position. Data across the four trials were baseline-corrected and then magnitude-normalized to the individual's highest absolute haemoglobin and oxygen signal during the 30-s maximal clenching effort. Haemoglobin and oxygen saturation increased progressively during cold pressor stimulation as the water temperature decreased (Hb, p < 0.0001; O2, p = 0.0327); very little effect was seen during the mock trial. Heart rate and blood pressure also increased progressively during the stimulation as the temperature decreased (heart rate, p = 0.0013; systolic blood pressure, p = 0.0042; diastolic blood pressure, p = 0.0156). These data suggest that cold pressor, stimulation induces a strong increase in intramuscular blood volume which appears to be due to both a local vasodilative response and increased cardiac output.

  1. Percutaneous transcatheter arterial embolization in haemodynamically stable patients with blunt splenic injury

    PubMed Central

    Popovic, Peter; Stanisavljevic, Dragoje; Jeromel, Miran

    2010-01-01

    Background The nonoperative management of the blunt splenic injury in haemodynamically stable patients has become an accepted treatment in recent years. We present a case of the blunt splenic injury successfully treated by supraselective embolization with microspheres. Case report. A young hockey player was brought to the Emergency Department with the history of blunt abdominal trauma 2 h earlier. A Grade III splenic injury with haemoperitoneum was diagnosed on sonographic evaluation and the patient was treated with the selective distal splenic artery embolization with microspheres. Postprocedural ultrasound and computed tomography follow-up a year later revealed only a small area of parenchymal irregularity. Conclusions The percutaneous splenic arterial embolization has a major role in the management of traumatic splenic injuries. Embolization is particularly beneficial in injuries of grade III or higher. PMID:22933888

  2. SERAPHIN haemodynamic substudy: the effect of the dual endothelin receptor antagonist macitentan on haemodynamic parameters and NT-proBNP levels and their association with disease progression in patients with pulmonary arterial hypertension

    PubMed Central

    Galiè, Nazzareno; Jansa, Pavel; Pulido, Tomás; Channick, Richard N.; Delcroix, Marion; Ghofrani, Hossein-Ardeschir; Le Brun, Franck-Olivier; Mehta, Sanjay; Perchenet, Loïc; Rubin, Lewis J.; Sastry, B.K.S.; Simonneau, Gérald; Sitbon, Olivier; Souza, Rogério; Torbicki, Adam

    2017-01-01

    Aims The effect of macitentan on haemodynamic parameters and NT-proBNP levels was evaluated in pulmonary arterial hypertension (PAH) patients in the SERAPHIN study. Association between these parameters and disease progression, assessed by the primary endpoint (time to first morbidity/mortality event), was explored. Methods and results Of the 742 randomized patients, 187 with right heart catheterization at baseline and month 6 participated in a haemodynamic sub-study. Prespecified endpoints included change from baseline to month 6 in cardiac index (CI), right atrial pressure (RAP), mean pulmonary arterial pressure (mPAP), pulmonary vascular resistance (PVR), mixed-venous oxygen saturation, and NT-proBNP. Exploratory analyses examined associations between CI, RAP, and NT-proBNP and disease progression using the Kaplan-Meier method and Cox regression models. Macitentan improved CI, RAP, mPAP, PVR and NT-proBNP vs. placebo at month 6. Absolute levels of CI, RAP and NT-proBNP at baseline and month 6, but not their changes, were associated with morbidity/mortality events. Patients with CI > 2.5 L/min/m2, RAP < 8 mmHg, or NT-proBNP < 750 fmol/ml at month 6 had a lower risk of morbidity/mortality than those not meeting these thresholds (HR 0.49, 95% CL 0.28–0.86; HR 0.72, 95% CL 0.42–1.22; and HR 0.22, 95% CL 0.15–0.33, respectively). Conclusions For all treatment groups, baseline and month 6 values of CI, RAP, and NT-proBNP, but not their changes, were associated with morbidity/mortality events, confirming their relevance in predicting disease progression in patients with PAH. By improving those parameters, macitentan increased the likelihood of reaching threshold values associated with lower risk of morbidity/mortality. PMID:28329315

  3. SERAPHIN haemodynamic substudy: the effect of the dual endothelin receptor antagonist macitentan on haemodynamic parameters and NT-proBNP levels and their association with disease progression in patients with pulmonary arterial hypertension.

    PubMed

    Galiè, Nazzareno; Jansa, Pavel; Pulido, Tomás; Channick, Richard N; Delcroix, Marion; Ghofrani, Hossein-Ardeschir; Le Brun, Franck-Olivier; Mehta, Sanjay; Perchenet, Loïc; Rubin, Lewis J; Sastry, B K S; Simonneau, Gérald; Sitbon, Olivier; Souza, Rogério; Torbicki, Adam

    2017-04-14

    The effect of macitentan on haemodynamic parameters and NT-proBNP levels was evaluated in pulmonary arterial hypertension (PAH) patients in the SERAPHIN study. Association between these parameters and disease progression, assessed by the primary endpoint (time to first morbidity/mortality event), was explored. Of the 742 randomized patients, 187 with right heart catheterization at baseline and month 6 participated in a haemodynamic sub-study. Prespecified endpoints included change from baseline to month 6 in cardiac index (CI), right atrial pressure (RAP), mean pulmonary arterial pressure (mPAP), pulmonary vascular resistance (PVR), mixed-venous oxygen saturation, and NT-proBNP. Exploratory analyses examined associations between CI, RAP, and NT-proBNP and disease progression using the Kaplan-Meier method and Cox regression models. Macitentan improved CI, RAP, mPAP, PVR and NT-proBNP vs. placebo at month 6. Absolute levels of CI, RAP and NT-proBNP at baseline and month 6, but not their changes, were associated with morbidity/mortality events. Patients with CI > 2.5 L/min/m2, RAP < 8 mmHg, or NT-proBNP < 750 fmol/ml at month 6 had a lower risk of morbidity/mortality than those not meeting these thresholds (HR 0.49, 95% CL 0.28-0.86; HR 0.72, 95% CL 0.42-1.22; and HR 0.22, 95% CL 0.15-0.33, respectively). For all treatment groups, baseline and month 6 values of CI, RAP, and NT-proBNP, but not their changes, were associated with morbidity/mortality events, confirming their relevance in predicting disease progression in patients with PAH. By improving those parameters, macitentan increased the likelihood of reaching threshold values associated with lower risk of morbidity/mortality. © The Author 2017. Published on behalf of the European Society of Cardiology

  4. Stability of continuous-time quantum filters with measurement imperfections

    NASA Astrophysics Data System (ADS)

    Amini, H.; Pellegrini, C.; Rouchon, P.

    2014-07-01

    The fidelity between the state of a continuously observed quantum system and the state of its associated quantum filter, is shown to be always a submartingale. The observed system is assumed to be governed by a continuous-time Stochastic Master Equation (SME), driven simultaneously by Wiener and Poisson processes and that takes into account incompleteness and errors in measurements. This stability result is the continuous-time counterpart of a similar stability result already established for discrete-time quantum systems and where the measurement imperfections are modelled by a left stochastic matrix.

  5. Continuous 24-hour measurement of middle ear pressure.

    PubMed

    Tideholm, B; Jönsson, S; Carlborg, B; Welinder, R; Grenner, J

    1996-07-01

    A new method was developed for continuous measurement of the middle ear pressure during a 24-h period. The equipment consisted of a piezo-electric pressure device and a digital memory. To allow continuous pressure recordings during normal every-day activities the equipment was made light and portable. The measurement accuracy of the equipment as well as the base-line and temperature stability were tested and found to meet to our requirements satisfactorily. In 4 volunteers with different middle ear conditions, a small perforation was made through the tympanic membrane. A rubber stopper containing a small polyethylene tube was fitted into the external ear canal. Tubal function tests were made to establish the equipment's ability to monitor fast pressure changes. The tests were well in accordance with other methods of direct pressure measurements. The equipment was carried by the volunteers for 24 h to monitor any slow or rapid dynamic pressure changes in the middle ear. Four continuous 24-h measurements are presented. The method was found to be suitable for valid measurements of dynamic pressure changes in the middle ear during normal every-day activities. It may become a useful instrument in the search for a better understanding of the development of chronic middle ear disease.

  6. Haemodynamical stress in mouse aortic arch with atherosclerotic plaques: Preliminary study of plaque progression

    PubMed Central

    Assemat, P.; Siu, K.K.; Armitage, J.A.; Hokke, S.N.; Dart, A.; Chin-Dusting, J.; Hourigan, K.

    2014-01-01

    Atherosclerotic plaques develop at particular sites in the arterial tree, and this regional localisation depends largely on haemodynamic parameters (such as wall shear stress; WSS) as described in the literature. Plaque rupture can result in heart attack or stroke and hence understanding the development and vulnerability of atherosclerotic plaques is critically important. The purpose of this study is to characterise the haemodynamics of blood flow in the mouse aortic arch using numerical modelling. The geometries are digitalised from synchrotron imaging and realistic pulsatile blood flow is considered under rigid wall assumptions. Two cases are considered; arteries with and without plaque. Mice that are fed under fat diet present plaques in the aortic arch whose size is dependent on the number of weeks under the diet. The plaque distribution in the region is however relatively constant through the different samples. This result underlines the influence of the geometry and consequently of the wall shear stresses for plaque formation with plaques growing in region of relative low shear stresses. A discussion of the flow field in real geometry in the presence and absence of plaques is conducted. The presence of plaques was shown to alter the blood flow and hence WSS distribution, with regions of localised high WSS, mainly on the wall of the brachiocephalic artery where luminal narrowing is most pronounced. In addition, arch plaques are shown to induce recirculation in the blood flow, a phenomenon with potential influence on the progression of the plaques. The oscillatory shear index and the relative residence time have been calculated on the geometry with plaques to show the presence of this recirculation in the arch, an approach that may be useful for future studies on plaque progression. PMID:25349678

  7. Randomised controlled trial examining the effect of an outpatient exercise training programme on haemodynamics and cardiac MR parameters of right ventricular function in patients with pulmonary arterial hypertension: the ExPAH study protocol.

    PubMed

    Chia, Karen S W; Faux, Steven G; Wong, Peter K K; Holloway, Cameron; Assareh, Hassan; McLachlan, Craig S; Kotlyar, Eugene

    2017-02-06

    Pulmonary hypertension (PH) is a potentially life-threatening condition characterised by elevated pulmonary artery pressure. Early stage PH patients are often asymptomatic. Disease progression is associated with impairment of right ventricular function and progressive dyspnoea. Current guidelines recommend exercise training (grade IIa, level B). However, many questions remain regarding the mechanisms of improvement, intensity of supervision and optimal frequency, duration and intensity of exercise. This study will assess the effect of an outpatient rehabilitation programme on haemodynamics and cardiac right ventricular function in patients with pulmonary arterial hypertension (PAH), a subgroup of PH. This randomised controlled trial involves both a major urban tertiary and smaller regional hospital in New South Wales, Australia. The intervention will compare an outpatient rehabilitation programme with a control group (home exercise programme). Participants will be stable on oral PAH-specific therapy. The primary outcome measure will be right ventricular ejection fraction measured by cardiac MRI. Secondary outcomes will include haemodynamics measured by right heart catheterisation, endurance, functional capacity, health-related quality of life questionnaires and biomarkers of cardiac function and inflammation. Ethical approval has been granted by St Vincent's Hospital, Sydney (HREC/14/SVH/341). Results of this study will be disseminated through presentation at scientific conferences and in scientific journals. ACTRN12615001041549; pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. Ultimate limits for quantum magnetometry via time-continuous measurements

    NASA Astrophysics Data System (ADS)

    Albarelli, Francesco; Rossi, Matteo A. C.; Paris, Matteo G. A.; Genoni, Marco G.

    2017-12-01

    We address the estimation of the magnetic field B acting on an ensemble of atoms with total spin J subjected to collective transverse noise. By preparing an initial spin coherent state, for any measurement performed after the evolution, the mean-square error of the estimate is known to scale as 1/J, i.e. no quantum enhancement is obtained. Here, we consider the possibility of continuously monitoring the atomic environment, and conclusively show that strategies based on time-continuous non-demolition measurements followed by a final strong measurement may achieve Heisenberg-limited scaling 1/{J}2 and also a monitoring-enhanced scaling in terms of the interrogation time. We also find that time-continuous schemes are robust against detection losses, as we prove that the quantum enhancement can be recovered also for finite measurement efficiency. Finally, we analytically prove the optimality of our strategy.

  9. SEMI-CONTINUOUS AEROSOL CARBON MEASUREMENTS: COMPARISON OF ATLANTA SUPERSITE MEASUREMENTS

    EPA Science Inventory

    An intensive field campaign of the Atlanta Supersite Experiment was carried out at a ground-based measurement site on Jefferson Street in midtown Atlanta, GA, from 3 August to 1 September, 1999. This paper examines the semi-continuous particulate organic and elemental measureme...

  10. Continuous quantum measurement in spin environments

    NASA Astrophysics Data System (ADS)

    Xie, Dong; Wang, An Min

    2015-08-01

    We derive a stochastic master equation (SME) which describes the decoherence dynamics of a system in spin environments conditioned on the measurement record. Markovian and non-Markovian nature of environment can be revealed by a spectroscopy method based on weak continuous quantum measurement. On account of that correlated environments can lead to a non-local open system which exhibits strong non-Markovian effects although the local dynamics are Markovian, the spectroscopy method can be used to demonstrate that there is correlation between two environments.

  11. Balloon pulmonary angioplasty relieves haemodynamic stress towards untreated-side pulmonary vasculature and improves its resistance in patients with chronic thromboembolic pulmonary hypertension.

    PubMed

    Hosokawa, Kazuya; Abe, Kohtaro; Horimoto, Koshin; Yamasaki, Yuzo; Nagao, Michinobu; Tsutsui, Hiroyuki

    2018-04-20

    Chronic thromboembolic pulmonary hypertension (CTEPH) is characterised by organised thrombotic obliteration of major vessels and small-vessel arteriopathy in the non-thrombosed vessels. The aim of this study was to investigate the impact of balloon pulmonary angioplasty (BPA) on the non-BPA-side pulmonary vasculature in patients with CTEPH. This study explored the outcomes of 20 unilateral BPA sessions in 13 CTEPH patients. We measured the pulmonary vascular resistance (PVR), pulmonary artery (PA) flow in the BPA-side and non-BPA-side lungs, respectively, using phase contrast MRI and cardiac catheterisation. The interval from BPA to the follow-up evaluation was 92.8±52.0 days. A single session of BPA decreased mean PA pressure from 37.4±6.2 to 30.9±6.5 mmHg (p<0.001). In the BPA side, BPA increased the PA flow from 1.58±0.65 to 1.95±0.62 L/min (p=0.001) and decreased the PVR from 27.3±27.4 to 14.4±9.0 Wood units (p=0.004). In contrast, it decreased both the non-BPA-side PA flow from 2.25±0.64 to 1.90±0.23 L/min (p=0.008) and the non-BPA-side PVR from 14.8±6.6 to 12.8±3.9 Wood units (p=0.01). BPA could relieve haemodynamic stress towards the non-BPA-side vasculature and decrease its PVR in patients with CTEPH, suggesting that it can suppress or regress the progression of the small-vessel arteriopathy in non-BPA-side vasculature, presumably due to haemodynamic unloading.

  12. Haemodynamic imaging of thoracic stent-grafts by computational fluid dynamics (CFD): presentation of a patient-specific method combining magnetic resonance imaging and numerical simulations.

    PubMed

    Midulla, Marco; Moreno, Ramiro; Baali, Adil; Chau, Ming; Negre-Salvayre, Anne; Nicoud, Franck; Pruvo, Jean-Pierre; Haulon, Stephan; Rousseau, Hervé

    2012-10-01

    In the last decade, there was been increasing interest in finding imaging techniques able to provide a functional vascular imaging of the thoracic aorta. The purpose of this paper is to present an imaging method combining magnetic resonance imaging (MRI) and computational fluid dynamics (CFD) to obtain a patient-specific haemodynamic analysis of patients treated by thoracic endovascular aortic repair (TEVAR). MRI was used to obtain boundary conditions. MR angiography (MRA) was followed by cardiac-gated cine sequences which covered the whole thoracic aorta. Phase contrast imaging provided the inlet and outlet profiles. A CFD mesh generator was used to model the arterial morphology, and wall movements were imposed according to the cine imaging. CFD runs were processed using the finite volume (FV) method assuming blood as a homogeneous Newtonian fluid. Twenty patients (14 men; mean age 62.2 years) with different aortic lesions were evaluated. Four-dimensional mapping of velocity and wall shear stress were obtained, depicting different patterns of flow (laminar, turbulent, stenosis-like) and local alterations of parietal stress in-stent and along the native aorta. A computational method using a combined approach with MRI appears feasible and seems promising to provide detailed functional analysis of thoracic aorta after stent-graft implantation. • Functional vascular imaging of the thoracic aorta offers new diagnostic opportunities • CFD can model vascular haemodynamics for clinical aortic problems • Combining CFD with MRI offers patient specific method of aortic analysis • Haemodynamic analysis of stent-grafts could improve clinical management and follow-up.

  13. Age-dependent effects of milrinone and levosimendan on ventricular function and haemodynamics in newborn and mature pigs.

    PubMed

    Hyldebrandt, Janus A; Larsen, Signe H; Schmidt, Michael R; Hjortdal, Vibeke E; Ravn, Hanne B

    2011-10-01

    Inodilators are used in the treatment of low cardiac output, mainly after cardiac surgery. At present, there is little knowledge of the effect of inodilators in the newborn heart. Immediately after birth and in the neonatal period, the metabolism and physiology of the heart undergo major changes. We hypothesised that effects of the inodilators milrinone and levosimendan on myocardial contractility and haemodynamics under normal physiological conditions were age dependent. Animal studies were conducted on 48 pigs using a closed-chest biventricular conductance catheter method. Pigs in two age groups, that is, 5-6 days and 5-6 weeks, were assigned to milrinone, levosimendan, or a control group. We observed that both milrinone - 19.2% with a p value of 0.05 - and levosimendan - 25.7% with a p value of 0.03 compared with the control group increased cardiac output, as well as myocardial contractility with a maximum pressure development over time: milrinone 28.2%, p = 0.01 and levosimendan 19.4%, p = 0.05. Milrinone improved diastolic performance (p < 0.05) in the left ventricle in the 5-6-week-old animals. In the newborn animals, neither of the inodilators increased ventricular contractility or cardiac output; however, we observed a significant decrease in the mean arterial pressure: milrinone 34.6%, p < 0.01 and levosimendan 30.1%, p = 0.02. Both inodilators demonstrated age-dependent haemodynamic effects, and it is noteworthy that neither milrinone nor levosimendan was able to increase cardiac output in the newborn heart.

  14. Acute resistance exercise with blood flow restriction in elderly hypertensive women: haemodynamic, rating of perceived exertion and blood lactate.

    PubMed

    Pinto, Roberta R; Karabulut, Murat; Poton, Roberto; Polito, Marcos D

    2018-01-01

    This study aimed to compare haemodynamic, rating of perceived exertion and blood lactate responses during resistance exercise with blood flow restriction (BFR) compared with traditional high-intensity resistance exercise in hypertensive older women. Eighteen hypertensive women (age = 67·0 ± 1·7 years.) undertook three random sessions: (i) three sets; 10 repetitions; 20% of one repetition maximum (1RM) with BFR; (ii) three sets; 10 repetitions; 65% of 1RM; without BFR; and (iii) no-exercise with BFR. The exercise sessions were performed on knee extension equipment. Systolic (SBP) and diastolic blood pressure (DBP), heart rate (HR), stroke volume (SV) and cardiac output (CO) were significantly higher (P<0·05) in all sets of exercise sessions than the control. No statistically significant differences were detected between exercise sessions. However, SBP, DBP and systemic vascular resistance were higher (P<0·05) and SV and CO were lower (P<0·05) during the rest intervals in the session with BFR. The perceived exertion was significantly higher (P<0·01) in the 1st (4·8 ± 0·4 versus 3·1 ± 0·3), 2nd (7·3 ± 0·4 versus 5·7 ± 0·4) and 3rd sets (8·6 ± 0·5 versus 7·5 ± 0·4) of the traditional high-intensity resistance exercise compared with the exercise with BFR. Blood lactate was higher (P<0·05) in the traditional high-intensity resistance exercise (6·2 ± 0·7 mmol) than in the exercise with BFR (4·5 ± 0·4 mmol). In comparison with high-intensity resistance exercise, low-intensity resistance exercise with BFR can elicit: (i) same haemodynamic values during exercise; (ii) lower rating of perceived exertion; (iii) lower blood lactate; (iv) higher haemodynamic demand during the rest intervals. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  15. Prefrontal cortex haemodynamics and affective responses during exercise: a multi-channel near infrared spectroscopy study.

    PubMed

    Tempest, Gavin D; Eston, Roger G; Parfitt, Gaynor

    2014-01-01

    The dose-response effects of the intensity of exercise upon the potential regulation (through top-down processes) of affective (pleasure-displeasure) responses in the prefrontal cortex during an incremental exercise protocol have not been explored. This study examined the functional capacity of the prefrontal cortex (reflected by haemodynamics using near infrared spectroscopy) and affective responses during exercise at different intensities. Participants completed an incremental cycling exercise test to exhaustion. Changes (Δ) in oxygenation (O2Hb), deoxygenation (HHb), blood volume (tHb) and haemoglobin difference (HbDiff) were measured from bilateral dorsal and ventral prefrontal areas. Affective responses were measured every minute during exercise. Data were extracted at intensities standardised to: below ventilatory threshold, at ventilatory threshold, respiratory compensation point and the end of exercise. During exercise at intensities from ventilatory threshold to respiratory compensation point, ΔO2Hb, ΔHbDiff and ΔtHb were greater in mostly ventral than dorsal regions. From the respiratory compensation point to the end of exercise, ΔO2Hb remained stable and ΔHbDiff declined in dorsal regions. As the intensity increased above the ventilatory threshold, inverse associations between affective responses and oxygenation in (a) all regions of the left hemisphere and (b) lateral (dorsal and ventral) regions followed by the midline (ventral) region in the right hemisphere were observed. Differential activation patterns occur within the prefrontal cortex and are associated with affective responses during cycling exercise.

  16. Prefrontal Cortex Haemodynamics and Affective Responses during Exercise: A Multi-Channel Near Infrared Spectroscopy Study

    PubMed Central

    Tempest, Gavin D.; Eston, Roger G.; Parfitt, Gaynor

    2014-01-01

    The dose-response effects of the intensity of exercise upon the potential regulation (through top-down processes) of affective (pleasure-displeasure) responses in the prefrontal cortex during an incremental exercise protocol have not been explored. This study examined the functional capacity of the prefrontal cortex (reflected by haemodynamics using near infrared spectroscopy) and affective responses during exercise at different intensities. Participants completed an incremental cycling exercise test to exhaustion. Changes (Δ) in oxygenation (O2Hb), deoxygenation (HHb), blood volume (tHb) and haemoglobin difference (HbDiff) were measured from bilateral dorsal and ventral prefrontal areas. Affective responses were measured every minute during exercise. Data were extracted at intensities standardised to: below ventilatory threshold, at ventilatory threshold, respiratory compensation point and the end of exercise. During exercise at intensities from ventilatory threshold to respiratory compensation point, ΔO2Hb, ΔHbDiff and ΔtHb were greater in mostly ventral than dorsal regions. From the respiratory compensation point to the end of exercise, ΔO2Hb remained stable and ΔHbDiff declined in dorsal regions. As the intensity increased above the ventilatory threshold, inverse associations between affective responses and oxygenation in (a) all regions of the left hemisphere and (b) lateral (dorsal and ventral) regions followed by the midline (ventral) region in the right hemisphere were observed. Differential activation patterns occur within the prefrontal cortex and are associated with affective responses during cycling exercise. PMID:24788166

  17. Cocaine-induced microvascular vasoconstriction but differential systemic haemodynamic responses in Yucatan versus Yorkshire varieties of swine.

    PubMed Central

    Miao, L.; Núñez, B. D.; Susulic, V.; Wheeler, S.; Carrozza, J. P.; Ross, J. N.; Morgan, J. P.

    1996-01-01

    1. Systemic and coronary haemodynamics were measured in 6 Yorkshire swine and 6 Yucatan miniature swine under isoflurane anaesthesia to investigate the influence of cocaine following its intravenous administration at 1, 3 and 7 mg kg-1. 2. Cocaine in Yorkshire swine decreased mean arterial pressure and rate pressure product (systolic pressure x heart rate), suggesting a cardiac depressant effect, whereas cocaine in Yucatan miniature swine increased these parameters, consistent with a hyperadrenergic state. 3. Cocaine in both Yorkshire swine and Yucatan miniature swine decreased coronary blood flow and coronary flow reserve, and increased coronary vascular resistance. 4. A modest generalized epicardial coronary artery constriction was observed by angiography, without evidence of focal spasm. 5. Our results confirm a marked vasoconstrictor effect of cocaine on the coronary arterial circulation, predominantly distal to the epicardial coronary arteries, but also indicate important differences in the systemic cardiovascular responses to the drug between two closely related strains of animals within the same species. Due to the similarities between the swine and human coronary arterial vasculature, we suggest that vasoconstriction in the coronary microcirculation may produce cardiac toxicity in man. PMID:8821549

  18. Uncountably many maximizing measures for a dense subset of continuous functions

    NASA Astrophysics Data System (ADS)

    Shinoda, Mao

    2018-05-01

    Ergodic optimization aims to single out dynamically invariant Borel probability measures which maximize the integral of a given ‘performance’ function. For a continuous self-map of a compact metric space and a dense set of continuous functions, we show the existence of uncountably many ergodic maximizing measures. We also show that, for a topologically mixing subshift of finite type and a dense set of continuous functions there exist uncountably many ergodic maximizing measures with full support and positive entropy.

  19. Human muscle sympathetic neural and haemodynamic responses to tilt following spaceflight

    NASA Technical Reports Server (NTRS)

    Levine, Benjamin D.; Pawelczyk, James A.; Ertl, Andrew C.; Cox, James F.; Zuckerman, Julie H.; Diedrich, Andre; Biaggioni, Italo; Ray, Chester A.; Smith, Michael L.; Iwase, Satoshi; hide

    2002-01-01

    Orthostatic intolerance is common when astronauts return to Earth: after brief spaceflight, up to two-thirds are unable to remain standing for 10 min. Previous research suggests that susceptible individuals are unable to increase their systemic vascular resistance and plasma noradrenaline concentrations above pre-flight upright levels. In this study, we tested the hypothesis that adaptation to the microgravity of space impairs sympathetic neural responses to upright posture on Earth. We studied six astronauts approximately 72 and 23 days before and on landing day after the 16 day Neurolab space shuttle mission. We measured heart rate, arterial pressure and cardiac output, and calculated stroke volume and total peripheral resistance, during supine rest and 10 min of 60 deg upright tilt. Muscle sympathetic nerve activity was recorded in five subjects, as a direct measure of sympathetic nervous system responses. As in previous studies, mean (+/- S.E.M.) stroke volume was lower (46 +/- 5 vs. 76 +/- 3 ml, P = 0.017) and heart rate was higher (93 +/- 1 vs. 74 +/- 4 beats min(-1), P = 0.002) during tilt after spaceflight than before spaceflight. Total peripheral resistance during tilt post flight was higher in some, but not all astronauts (1674 +/- 256 vs. 1372 +/- 62 dynes s cm(-5), P = 0.32). No crew member exhibited orthostatic hypotension or presyncopal symptoms during the 10 min of postflight tilting. Muscle sympathetic nerve activity was higher post flight in all subjects, in supine (27 +/- 4 vs. 17 +/- 2 bursts min(-1), P = 0.04) and tilted (46 +/- 4 vs. 38 +/- 3 bursts min(-1), P = 0.01) positions. A strong (r(2) = 0.91-1.00) linear correlation between left ventricular stroke volume and muscle sympathetic nerve activity suggested that sympathetic responses were appropriate for the haemodynamic challenge of upright tilt and were unaffected by spaceflight. We conclude that after 16 days of spaceflight, muscle sympathetic nerve responses to upright tilt are normal.

  20. Human muscle sympathetic neural and haemodynamic responses to tilt following spaceflight

    PubMed Central

    Levine, Benjamin D; Pawelczyk, James A; Ertl, Andrew C; Cox, James F; Zuckerman, Julie H; Diedrich, André; Biaggioni, Italo; Ray, Chester A; Smith, Michael L; Iwase, Satoshi; Saito, Mitsuru; Sugiyama, Yoshiki; Mano, Tadaaki; Zhang, Rong; Iwasaki, Kenichi; Lane, Lynda D; Buckey, Jay C; Cooke, William H; Baisch, Friedhelm J; Robertson, David; Eckberg, Dwain L; Blomqvist, C Gunnar

    2002-01-01

    Orthostatic intolerance is common when astronauts return to Earth: after brief spaceflight, up to two-thirds are unable to remain standing for 10 min. Previous research suggests that susceptible individuals are unable to increase their systemic vascular resistance and plasma noradrenaline concentrations above pre-flight upright levels. In this study, we tested the hypothesis that adaptation to the microgravity of space impairs sympathetic neural responses to upright posture on Earth. We studied six astronauts ∼72 and 23 days before and on landing day after the 16 day Neurolab space shuttle mission. We measured heart rate, arterial pressure and cardiac output, and calculated stroke volume and total peripheral resistance, during supine rest and 10 min of 60 deg upright tilt. Muscle sympathetic nerve activity was recorded in five subjects, as a direct measure of sympathetic nervous system responses. As in previous studies, mean (± s.e.m.) stroke volume was lower (46 ± 5 vs. 76 ± 3 ml, P = 0.017) and heart rate was higher (93 ± 1 vs. 74 ± 4 beats min−1, P = 0.002) during tilt after spaceflight than before spaceflight. Total peripheral resistance during tilt post flight was higher in some, but not all astronauts (1674 ± 256 vs. 1372 ± 62 dynes s cm−5, P = 0.32). No crew member exhibited orthostatic hypotension or presyncopal symptoms during the 10 min of postflight tilting. Muscle sympathetic nerve activity was higher post flight in all subjects, in supine (27 ± 4 vs. 17 ± 2 bursts min−1, P = 0.04) and tilted (46 ± 4 vs. 38 ± 3 bursts min−1, P = 0.01) positions. A strong (r2 = 0.91–1.00) linear correlation between left ventricular stroke volume and muscle sympathetic nerve activity suggested that sympathetic responses were appropriate for the haemodynamic challenge of upright tilt and were unaffected by spaceflight. We conclude that after 16 days of spaceflight, muscle sympathetic nerve responses to upright tilt are normal. PMID:11773340

  1. Assessing paedophilia based on the haemodynamic brain response to face images.

    PubMed

    Ponseti, Jorge; Granert, Oliver; Van Eimeren, Thilo; Jansen, Olav; Wolff, Stephan; Beier, Klaus; Deuschl, Günther; Huchzermeier, Christian; Stirn, Aglaja; Bosinski, Hartmut; Roman Siebner, Hartwig

    2016-01-01

    Objective assessment of sexual preferences may be of relevance in the treatment and prognosis of child sexual offenders. Previous research has indicated that this can be achieved by pattern classification of brain responses to sexual child and adult images. Our recent research showed that human face processing is tuned to sexual age preferences. This observation prompted us to test whether paedophilia can be inferred based on the haemodynamic brain responses to adult and child faces. Twenty-four men sexually attracted to prepubescent boys or girls (paedophiles) and 32 men sexually attracted to men or women (teleiophiles) were exposed to images of child and adult, male and female faces during a functional magnetic resonance imaging (fMRI) session. A cross-validated, automatic pattern classification algorithm of brain responses to facial stimuli yielded four misclassified participants (three false positives), corresponding to a specificity of 91% and a sensitivity of 95%. These results indicate that the functional response to facial stimuli can be reliably used for fMRI-based classification of paedophilia, bypassing the problem of showing child sexual stimuli to paedophiles.

  2. Comparison of haemodynamic responses following different concentrations of adrenaline with and without lignocaine for surgical field infiltration during cleft lip and cleft palate surgery in children.

    PubMed

    Muthukumar, Marimuthu; Arya, Virendra K; Mathew, Preety J; Sharma, Ramesh K

    2012-01-01

    Surgical field infiltration with adrenaline is common practice for quality surgical field during cleft lip and palate repair in children. Intravascular absorption of adrenaline infiltration often leads to adverse haemodynamic responses. In this prospective, double-blinded, randomised study the haemodynamic effects, quality of surgical field and postoperative analgesia following surgical field infiltration with different concentrations of adrenaline with and without lignocaine were compared in 100 American Society of Anesthesiologists physical status I children aged six months to seven years undergoing cleft lip/palate surgery. A standard anaesthesia protocol was used and they were randomised into four groups based on solution for infiltration: adrenaline 1:400,000 (group A), adrenaline 1:200,000 (group B), lignocaine + adrenaline 1:400,000 (group C) and lignocaine + adrenaline 1:200,000 (group D). Statistically significant tachycardia and hypertension occurred only in group B as compared to other groups (P <0.001). The peak changes in heart rate and mean arterial pressure following infiltration occurred at 4.3 ± 2.4, 3.8 ± 1.5, 5.7 ± 3.2 and 5.9 ± 4.9 minutes in groups A, B, C and D respectively. Surgical field was comparable among all groups. Postoperative pain scores and rescue analgesic requirements were lesser in the groups where lignocaine was added to the infiltrating solution (P <0.05). We found that 1:400000 or 1:200000 adrenaline with lignocaine 0.5 to 0.7% is most suitable for infiltration in terms of stable haemodynamics, quality of surgical field and good postoperative analgesia in children.

  3. Comparison of two methods for cardiac output measurement in critically ill patients.

    PubMed

    Saraceni, E; Rossi, S; Persona, P; Dan, M; Rizzi, S; Meroni, M; Ori, C

    2011-05-01

    The aim of recent haemodynamic monitoring has been to obtain continuous and reliable measures of cardiac output (CO) and indices of preload responsiveness. Many of these methods are based on the arterial pressure waveform analysis. The aim of our study was to assess the accuracy of CO measurements obtained by FloTrac/Vigileo, software version 1.07 and the new version 1.10 (Edwards Lifesciences LLC, Irvine, CA, USA), compared with CO measurements obtained by bolus thermodilution by pulmonary artery catheterization (PAC) in the intensive care setting. In 21 critically ill patients (enrolled in two University Hospitals), requiring invasive haemodynamic monitoring, PAC and FloTrac/Vigileo transducers connected to the arterial pressure line were placed. Simultaneous measurements of CO by two methods (FloTrac/Vigileo and thermodilution) were obtained three times a day for 3 consecutive days, when possible. The level of concordance between the two methods was assessed by the procedure suggested by Bland and Altman. One hundred and forty-one pairs of measurements (provided by thermodilution and by both 1.07 and 1.10 FloTrac/Vigileo versions) were obtained in 21 patients (seven of them were trauma patients) with a mean (sd) age of 59 (16) yr. The Pearson product moment coefficient was 0.62 (P<0.001). The bias was -0.18 litre min(-1). The limits of agreement were 4.54 and -4.90 litre min(-1), respectively. Our data show a poor level of concordance between measures provided by the two methods. We found an underestimation of CO values measured with the 1.07 software version of FloTrac for supranormal values of CO. The new software (1.10) has been improved in order to correct this bias; however, its reliability is still poor. On the basis of our data, we can therefore conclude that both software versions of FloTrac/Vigileo did not still provide reliable estimation of CO in our intensive care unit setting.

  4. Cardiorespiratory interaction with continuous positive airway pressure

    PubMed Central

    Bonafini, Sara; Fava, Cristiano; Steier, Joerg

    2018-01-01

    The treatment of choice for obstructive sleep apnoea (OSA) is continuous positive airway pressure therapy (CPAP). Since its introduction in clinical practice, CPAP has been used in various clinical conditions with variable and heterogeneous outcomes. In addition to the well-known effects on the upper airway CPAP impacts on intrathoracic pressures, haemodynamics and blood pressure (BP) control. However, short- and long-term effects of CPAP therapy depend on multiple variables which include symptoms, underlying condition, pressure used, treatment acceptance, compliance and usage. CPAP can alter long-term cardiovascular risk in patients with cardiorespiratory conditions. Furthermore, the effect of CPAP on the awake patient differs from the effect on the patients while asleep, and this might contribute to discomfort and removal of the use interface. The purpose of this review is to highlight the physiological impact of CPAP on the cardiorespiratory system, including short-term benefits and long-term outcomes. PMID:29445529

  5. 78 FR 69927 - Notice to Manufacturers of Continuous Friction Measurement Equipment (CFME)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-21

    ... Friction Measurement Equipment (CFME) AGENCY: Federal Aviation Administration (FAA), US DOT. ACTION: Notice... (FAA) is considering issuing waivers to foreign manufacturers of Continuous Friction Measurement... entitled, Continuous Friction Measurement Equipment Request for Qualifications. The FAA wants to determine...

  6. EMuJoy: software for continuous measurement of perceived emotions in music.

    PubMed

    Nagel, Frederik; Kopiez, Reinhard; Grewe, Oliver; Altenmüller, Eckart

    2007-05-01

    An adequate study of emotions in music and film should be based on the real-time measurement of self-reported data using a continuous-response method. The recording system discussed in this article reflects two important aspects of such research: First, for a better comparison of results, experimental and technical standards for continuous measurement should be taken into account, and second, the recording system should be open to the inclusion of multimodal stimuli. In light of these two considerations, our article addresses four basic principles of the continuous measurement of emotions: (1) the dimensionality of the emotion space, (2) data acquisition (e.g., the synchronization of media and the self-reported data), (3) interface construction for emotional responses, and (4) the use of multiple stimulus modalities. Researcher-developed software (EMuJoy) is presented as a freeware solution for the continuous measurement of responses to different media, along with empirical data from the self-reports of 38 subjects listening to emotional music and viewing affective pictures.

  7. Disease management: remote monitoring in heart failure patients with implantable defibrillators, resynchronization devices, and haemodynamic monitors.

    PubMed

    Abraham, William T

    2013-06-01

    Heart failure represents a major public health concern, associated with high rates of morbidity and mortality. A particular focus of contemporary heart failure management is reduction of hospital admission and readmission rates. While optimal medical therapy favourably impacts the natural history of the disease, devices such as cardiac resynchronization therapy devices and implantable cardioverter defibrillators have added incremental value in improving heart failure outcomes. These devices also enable remote patient monitoring via device-based diagnostics. Device-based measurement of physiological parameters, such as intrathoracic impedance and heart rate variability, provide a means to assess risk of worsening heart failure and the possibility of future hospitalization. Beyond this capability, implantable haemodynamic monitors have the potential to direct day-to-day management of heart failure patients to significantly reduce hospitalization rates. The use of a pulmonary artery pressure measurement system has been shown to significantly reduce the risk of heart failure hospitalization in a large randomized controlled study, the CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Class III Heart Failure Patients (CHAMPION) trial. Observations from a pilot study also support the potential use of a left atrial pressure monitoring system and physician-directed patient self-management paradigm; these observations are under further investigation in the ongoing LAPTOP-HF trial. All these devices depend upon high-intensity remote monitoring for successful detection of parameter deviations and for directing and following therapy.

  8. Exaggerated haemodynamic and neural responses to involuntary contractions induced by whole-body vibration in normotensive obese versus lean women.

    PubMed

    Dipla, Konstantina; Kousoula, Dimitra; Zafeiridis, Andreas; Karatrantou, Konstantina; Nikolaidis, Michalis G; Kyparos, Antonios; Gerodimos, Vassilis; Vrabas, Ioannis S

    2016-06-01

    What is the central question of this study? In obesity, the exaggerated blood pressure response to voluntary exercise is linked to hypertension, yet the mechanisms are not fully elucidated. We examined whether involuntary contractions elicit greater haemodynamic responses and altered neural control of blood pressure in normotensive obese versus lean women. What is the main finding and its importance? During involuntary contractions induced by whole-body vibration, there were augmented blood pressure and spontaneous baroreflex responses in obese compared with lean women. This finding is suggestive of an overactive mechanoreflex in the exercise-induced hypertensive response in obesity. Passive contractions did not elicit differential heart rate responses in obese compared with lean women, implying other mechanisms for the blunted heart rate response reported during voluntary exercise in obesity. In obesity, the exaggerated blood pressure (BP) response to exercise is linked to hypertension, yet the mechanisms are not fully elucidated. In this study, we examined whether involuntary mechanical oscillations, induced by whole-body vibration (WBV), elicit greater haemodynamic responses and altered neural control of BP in obese versus lean women. Twenty-two normotensive, premenopausal women (12 lean and 10 obese) randomly underwent a passive WBV (25 Hz) and a control protocol (similar posture without WVB). Beat-by-beat BP, heart rate, stroke volume, systemic vascular resistance, cardiac output, parasympathetic output (evaluated by heart rate variability) and spontaneous baroreceptor sensitivity (sBRS) were assessed. We found that during WBV, obese women exhibited an augmented systolic BP response compared with lean women that was correlated with body fat percentage (r = 0.77; P < 0.05). The exaggerated BP rise was driven mainly by the greater increase in cardiac output index in obese versus lean women, associated with a greater stroke volume index in obese women

  9. Effects of preemptive analgesia with parecoxib sodium on haemodynamics and plasma stress hormones in surgical patients with thyroid carcinoma.

    PubMed

    Wang, Lian-Dong; Gao, Xia; Li, Jun-Ying; Yu, Hong-Yan; Su, Hai-Wen; Liu, Lian-Zhong; Qi, Jun

    2015-01-01

    To investigate the effects of preemptive analgesia with parecoxib sodium on haemodynamics and plasma stress hormones in surgical patients with thyroid carcinoma. Fifty-seven patients with thyroid carcinoma who underwent thyroidectomy selectively in Laiwu Hospital Affiliated to Taishan Medical University and Binzhou People's Hospital were selected and randomly divided into three groups, 19 cases in each group. The control group was intravenously injected 0.9% sodium chloride injection before anesthesia induction; trial group I was intravenously injected with parecoxib sodium 20 min before anesthesia induction; based on trial group I, trial group II was injected with parecoxib sodium again 12 h after surgery. The levels of plasma norepinephrine (NE), cortisol (Cor) and blood glucose before, 12 and 24 h after surgery and changes of haemodynamics before surgery, at the end of surgery and 12, 24 and 48 h after surgery were compared in the three groups. Besides, visual analogue scale (VAS) scores were recorded 4, 8, 12 and 24 h after surgery. 12 and 24 h after surgery, the levels of plasma NE and Cor in three groups rose dramatically (P<0.05 or (P<0.01); The levels of plasma NE and Cor in trial groups I and II were evidently lower than in control group (P<0.05 or P<0.01), and those in trial group II slightly lower than in trial group I. 12 h after surgery, the heart rates (HR) and systolic pressures (SBP) in trial groups I and II increased obviously by comparison to surgery before (P<0.05 or P<0.01), but gradually returned to the preoperative level. HR, SBP and diastolic pressures (DBP) in trial groups I and II at the end of surgery and 12 h after surgery were all lower than in the control group, and significant differences were present (P<0.05 or (P<0.01). At 4, 8, 12 and 24 h after surgery, VAS scores in trial groups I and II were markedly lower than in the control group ((P<0.05 or (P<0.01), the scores in trial group II being the lowest. Combined application of

  10. Haemodynamic responses to dehydration in the resting and exercising human leg.

    PubMed

    Pearson, James; Kalsi, Kameljit K; Stöhr, Eric J; Low, David A; Barker, Horace; Ali, Leena; González-Alonso, José

    2013-06-01

    Dehydration and hyperthermia reduces leg blood flow (LBF), cardiac output ([Formula: see text]) and arterial pressure during whole-body exercise. It is unknown whether the reductions in blood flow are associated with dehydration-induced alterations in arterial blood oxygen content (C aO2) and O2-dependent signalling. This study investigated the impact of dehydration and concomitant alterations in C aO2 upon LBF and [Formula: see text]. Haemodynamics, arterial and femoral venous blood parameters and plasma [ATP] were measured at rest and during one-legged knee-extensor exercise in 7 males in four conditions: (1) control, (2) mild dehydration, (3) moderate dehydration, and (4) rehydration. Relative to control, C aO2 and LBF increased with dehydration at rest and during exercise (C aO2: from 199 ± 1 to 208 ± 2, and 202 ± 2 to 210 ± 2 ml L(-1) and LBF: from 0.38 ± 0.04 to 0.77 ± 0.09, and 1.64 ± 0.09 to 1.88 ± 0.1 L min(-1), respectively). Similarly, [Formula: see text] was unchanged or increased with dehydration at rest and during exercise, whereas arterial and leg perfusion pressures declined. Following rehydration, C aO2 declined (to 193 ± 2 mL L(-1)) but LBF remained elevated. Alterations in LBF were unrelated to C aO2 (r (2) = 0.13-0.27, P = 0.48-0.64) and plasma [ATP]. These findings suggest dehydration and concomitant alterations in C aO2 do not compromise LBF despite reductions in plasma [ATP]. While an additive or synergistic effect cannot be excluded, reductions in LBF during exercise with dehydration may not necessarily be associated with alterations in C aO2 and/or intravascular [ATP].

  11. The influence of water ingestion on postexercise hypotension and standing haemodynamics.

    PubMed

    Mendonca, Goncalo V; Fernhall, Bo

    2016-11-01

    In young healthy adults, postexercise hypotension (PEH) occurs after a single bout of dynamic exercise due to peripheral vasodilation. Gravitational stress may further aggravate the magnitude of PEH, thus predisposing to orthostatic intolerance. As water drinking activates sympathetic vasoconstriction, it might offset PEH via enhanced α-adrenergic vascular responsiveness. We hypothesized that water ingestion before exercise would decrease the magnitude of PEH and improve the haemodynamic reaction to active standing postmaximal exercise. In a randomized fashion, 17 healthy adults (nine men; eight women, 21·2 ± 1·6 years) ingested 50 and 500 ml of water before completing resting, cycle ergometer and recovery protocols on two separate days. After exercise, measurements [arterial blood pressure (BP), heart rate and spectral heart rate variability (HRV)] were taken in the seated position followed by 5 min of active standing. Compared to that seen post-50 ml of water, the 500 ml volume elicited an overall increase in BP (P < 0·05). Nevertheless, the magnitude of PEH was not different after either volume of water. There was an overall bradycardic effect of water, and this was accompanied by increased high-frequency power (P < 0·05). Finally, no BP, heart rate or HRV differences were found between conditions in response to active standing. These data suggest that, despite being well preserved after maximal exercise, the water pressor response does not affect the magnitude of PEH. They also indicate that drinking 500 ml of water does not impact the BP, heart rate or HRV response to 5 min of active standing during recovery postmaximal exercise. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  12. Continuous-flow water sampler for real-time isotopic water measurements

    NASA Astrophysics Data System (ADS)

    Carter, J.; Dennis, K.

    2013-12-01

    Measuring the stable isotopes of liquid water (δ18O and δD) is a tool familiar to many Earth scientists, but most current techniques require discrete sampling. For example, isotope ratio mass spectrometry requires the collection of aliquots of water that are then converted to CO2, CO or H2 for analysis. Similarly, laser-based techniques, such as Cavity Ring-Down Spectroscopy (CRDS) convert discrete samples (typically < 2μL) of liquid water to water vapor using a flash vaporization process. By requiring the use of discrete samples fine-scale spatial and temporal studies of changes in δ18O and δD are limited. Here we present a continuous-flow water sampler that will enable scientists to probe isotopic changes in real-time, with applications including, but not limited to, quantification of the 'amount effect' (Dansgaard, 1964) during an individual precipitation event or storm track, real-time mixing of water in river systems, and shipboard continuous water measurements (Munksgaard et al., 2012). Due to the inherent ability of CRDS to measure a continuous flow of water vapor it is an ideal candidate for interfacing with a continuous water sampling system. Here we present results from the first commercially available continuous-flow water sampler, developed by engineers at Picarro. This peripheral device is compatible with Picarro CRDS isotopic water analyzers, allowing real-time, continuous isotopic measurements of liquid water. The new device, which expands upon the design of Munskgaard et al. (2011), utilizes expanded polytetrafluoroethylene (ePTFE) membrane technology to continuously generate gas-phase water, while liquid water is pumped through the system. The water vapor subsequently travels to the CRDS analyzer where the isotopic ratios are measured and recorded. The generation of water vapor using membrane technology is sensitive to environmental conditions, which if not actively control, lead to sustainable experimental noise and drift. Consequently, our

  13. Continuous real-time measurement of aqueous cyanide

    DOEpatents

    Rosentreter, Jeffrey J.; Gering, Kevin L.

    2007-03-06

    This invention provides a method and system capable of the continuous, real-time measurement of low concentrations of aqueous free cyanide (CN) using an on-line, flow through system. The system is based on the selective reactivity of cyanide anions and the characteristically nonreactive nature of metallic gold films, wherein this selective reactivity is exploited as an indirect measurement for aqueous cyanide. In the present invention the dissolution of gold, due to the solubilization reaction with the analyte cyanide anion, is monitored using a piezoelectric microbalance contained within a flow cell.

  14. Continuous Mass Measurement on Conveyor Belt

    NASA Astrophysics Data System (ADS)

    Tomobe, Yuki; Tasaki, Ryosuke; Yamazaki, Takanori; Ohnishi, Hideo; Kobayashi, Masaaki; Kurosu, Shigeru

    The continuous mass measurement of packages on a conveyor belt will become greatly important. In the mass measurement, the sequence of products is generally random. An interesting possibility of raising throughput of the conveyor line without increasing the conveyor belt speed is offered by the use of two or three conveyor belt scales (called a multi-stage conveyor belt scale). The multi-stage conveyor belt scale can be created which will adjust the conveyor belt length to the product length. The conveyor belt scale usually has maximum capacities of less than 80kg and 140cm, and achieves measuring rates of more than 150 packages per minute and more. The output signals from the conveyor belt scale are always contaminated with noises due to vibrations of the conveyor and the product to be measured in motion. In this paper an employed digital filter is of Finite Impulse Response (FIR) type designed under the consideration on the dynamics of the conveyor system. The experimental results on the conveyor belt scale suggest that the filtering algorithms are effective enough to practical applications to some extent.

  15. Haemodynamic results of replacement of mitral and aortic valves with autologous fascia lata prostheses

    PubMed Central

    Talavlikar, P. H.; Walbaum, P. R.; Kitchin, A. H.

    1973-01-01

    Twelve patients undergoing aortic and 28 undergoing mitral valve replacement with autologous fascia lata valves were studied before and six months after surgery. One aortic and 10 mitral valves were found to be significantly incompetent. Of the incompetent mitral valves, two appeared to have perivalvular leaks. Six of the remainder were associated with abnormal ventricular filling patterns. Valve failure was much less common when the design was modified to provide a loose cusp structure; out of 12 such valves none was incompetent. Transvalvular gradients persist with fascial valves though they are lower than with most mechanical prostheses. Ventricular function was greatly improved in successful aortic replacement but remained impaired in the case of mitral replacement. Valve failure appeared to be associated with, or accelerated by, haemodynamic stress rather than due to inevitable degenerative pathological processes. PMID:4731108

  16. Violation of Bell's Inequality Using Continuous Variable Measurements

    NASA Astrophysics Data System (ADS)

    Thearle, Oliver; Janousek, Jiri; Armstrong, Seiji; Hosseini, Sara; Schünemann Mraz, Melanie; Assad, Syed; Symul, Thomas; James, Matthew R.; Huntington, Elanor; Ralph, Timothy C.; Lam, Ping Koy

    2018-01-01

    A Bell inequality is a fundamental test to rule out local hidden variable model descriptions of correlations between two physically separated systems. There have been a number of experiments in which a Bell inequality has been violated using discrete-variable systems. We demonstrate a violation of Bell's inequality using continuous variable quadrature measurements. By creating a four-mode entangled state with homodyne detection, we recorded a clear violation with a Bell value of B =2.31 ±0.02 . This opens new possibilities for using continuous variable states for device independent quantum protocols.

  17. Refractory thermowell for continuous high temperature measurement of molten metal

    DOEpatents

    Thiesen, Todd J.

    1992-01-01

    An apparatus for the continuous high temperature measurement of materials in vessels lined with rammed or cast refractory materials. A refractory housing member is integral with the refractory lining of the vessel and contains a plurality of high temperature sensing means, such as thermocouples. A face of the housing is flush with the refractory lining and contacts the high temperature material contained in the vessel. Continuous temperature measurement is achieved by a means which is coupled to the thermocouples for indicating the temperature.

  18. Measures of Quantum Synchronization in Continuous Variable Systems

    NASA Astrophysics Data System (ADS)

    Mari, A.; Farace, A.; Didier, N.; Giovannetti, V.; Fazio, R.

    2013-09-01

    We introduce and characterize two different measures which quantify the level of synchronization of coupled continuous variable quantum systems. The two measures allow us to extend to the quantum domain the notions of complete and phase synchronization. The Heisenberg principle sets a universal bound to complete synchronization. The measure of phase synchronization is, in principle, unbounded; however, in the absence of quantum resources (e.g., squeezing) the synchronization level is bounded below a certain threshold. We elucidate some interesting connections between entanglement and synchronization and, finally, discuss an application based on quantum optomechanical systems.

  19. Measures of quantum synchronization in continuous variable systems.

    PubMed

    Mari, A; Farace, A; Didier, N; Giovannetti, V; Fazio, R

    2013-09-06

    We introduce and characterize two different measures which quantify the level of synchronization of coupled continuous variable quantum systems. The two measures allow us to extend to the quantum domain the notions of complete and phase synchronization. The Heisenberg principle sets a universal bound to complete synchronization. The measure of phase synchronization is, in principle, unbounded; however, in the absence of quantum resources (e.g., squeezing) the synchronization level is bounded below a certain threshold. We elucidate some interesting connections between entanglement and synchronization and, finally, discuss an application based on quantum optomechanical systems.

  20. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.

    PubMed

    Gholamhosseini, Hamid; Meintjes, Andries; Baig, Mirza; Linden, Maria

    2016-01-01

    The increasing availability of low cost and easy to use personalized medical monitoring devices has opened the door for new and innovative methods of health monitoring to emerge. Cuff-less and continuous methods of measuring blood pressure are particularly attractive as blood pressure is one of the most important measurements of long term cardiovascular health. Current methods of noninvasive blood pressure measurement are based on inflation and deflation of a cuff with some effects on arteries where blood pressure is being measured. This inflation can also cause patient discomfort and alter the measurement results. In this work, a mobile application was developed to collate the PhotoPlethysmoGramm (PPG) waveform provided by a pulse oximeter and the electrocardiogram (ECG) for calculating the pulse transit time. This information is then indirectly related to the user's systolic blood pressure. The developed application successfully connects to the PPG and ECG monitoring devices using Bluetooth wireless connection and stores the data onto an online server. The pulse transit time is estimated in real time and the user's systolic blood pressure can be estimated after the system has been calibrated. The synchronization between the two devices was found to pose a challenge to this method of continuous blood pressure monitoring. However, the implemented continuous blood pressure monitoring system effectively serves as a proof of concept. This combined with the massive benefits that an accurate and robust continuous blood pressure monitoring system would provide indicates that it is certainly worthwhile to further develop this system.

  1. Capacitance variation measurement method with a continuously variable measuring range for a micro-capacitance sensor

    NASA Astrophysics Data System (ADS)

    Lü, Xiaozhou; Xie, Kai; Xue, Dongfeng; Zhang, Feng; Qi, Liang; Tao, Yebo; Li, Teng; Bao, Weimin; Wang, Songlin; Li, Xiaoping; Chen, Renjie

    2017-10-01

    Micro-capacitance sensors are widely applied in industrial applications for the measurement of mechanical variations. The measurement accuracy of micro-capacitance sensors is highly dependent on the capacitance measurement circuit. To overcome the inability of commonly used methods to directly measure capacitance variation and deal with the conflict between the measurement range and accuracy, this paper presents a capacitance variation measurement method which is able to measure the output capacitance variation (relative value) of the micro-capacitance sensor with a continuously variable measuring range. We present the principles and analyze the non-ideal factors affecting this method. To implement the method, we developed a capacitance variation measurement circuit and carried out experiments to test the circuit. The result shows that the circuit is able to measure a capacitance variation range of 0-700 pF linearly with a maximum relative accuracy of 0.05% and a capacitance range of 0-2 nF (with a baseline capacitance of 1 nF) with a constant resolution of 0.03%. The circuit is proposed as a new method to measure capacitance and is expected to have applications in micro-capacitance sensors for measuring capacitance variation with a continuously variable measuring range.

  2. Measurement properties of continuous text reading performance tests.

    PubMed

    Brussee, Tamara; van Nispen, Ruth M A; van Rens, Ger H M B

    2014-11-01

    Measurement properties of tests to assess reading acuity or reading performance have not been extensively evaluated. This study aims to provide an overview of the literature on available continuous text reading tests and their measurement properties. A literature search was performed in PubMed, Embase and PsycInfo. Subsequently, information on design and content of reading tests, study design and measurement properties were extracted using consensus-based standards for selection of health measurement instruments. Quality of studies, reading tests and measurement properties were systematically assessed using pre-specified criteria. From 2334 identified articles, 20 relevant articles were found on measurement properties of three reading tests in various languages: IReST, MNread Reading Test and Radner Reading Charts. All three reading tests scored high on content validity. Reproducibility studies (repeated measurements between different testing sessions) of the IReST and MNread of commercially available reading tests in different languages were missing. The IReST scored best on inter-language comparison, the MNread scored well in repeatability studies (repeated measurements under the same conditions) and the Radner showed good reproducibility in studies. Although in daily practice there are other continuous text reading tests available meeting the criteria of this review, measurement properties were described in scientific studies for only three of them. Of the few available studies, the quality and content of study design and methodology used varied. For testing existing reading tests and the development of new ones, for example in other languages, we make several recommendations, including careful description of patient characteristics, use of objective and subjective lighting levels, good control of working distance, documentation of the number of raters and their training, careful documentation of scoring rules and the use of Bland-Altman analyses or similar for

  3. Measuring the development of inhibitory control: The challenge of heterotypic continuity

    PubMed Central

    Petersen, Isaac T.; Hoyniak, Caroline P.; McQuillan, Maureen E.; Bates, John E.; Staples, Angela D.

    2016-01-01

    Inhibitory control is thought to demonstrate heterotypic continuity, in other words, continuity in its purpose or function but changes in its behavioral manifestation over time. This creates major methodological challenges for studying the development of inhibitory control in childhood including construct validity, developmental appropriateness and sensitivity of measures, and longitudinal factorial invariance. We meta-analyzed 198 studies using measures of inhibitory control, a key aspect of self-regulation, to estimate age ranges of usefulness for each measure. The inhibitory control measures showed limited age ranges of usefulness owing to ceiling/floor effects. Tasks were useful, on average, for a developmental span of less than 3 years. This suggests that measuring inhibitory control over longer spans of development may require use of different measures at different time points, seeking to measure heterotypic continuity. We suggest ways to study the development of inhibitory control, with overlapping measurement in a structural equation modeling framework and tests of longitudinal factorial or measurement invariance. However, as valuable as this would be for the area, we also point out that establishing longitudinal factorial invariance is neither sufficient nor necessary for examining developmental change. Any study of developmental change should be guided by theory and construct validity, aiming toward a better empirical and theoretical approach to the selection and combination of measures. PMID:27346906

  4. Propofol-fentanyl anaesthesia at high altitude: anaesthetic requirements and haemodynamic variations when compared with anaesthesia at low altitude.

    PubMed

    Puri, G D; Jayant, A; Dorje, M; Tashi, M

    2008-03-01

    There are few published accounts of anaesthesia delivery at high altitude. Natives at high altitude are known to have altered cardiorespiratory reserve. This study seeks to demonstrate the safety of propofol-fentanyl anaesthesia at high altitude titrated to the bispectral index (BIS) (3505 metres above sea level) in native highlanders. It also shows the differential effects of anaesthesia and surgery on the haemodynamics of such individuals as compared with individuals living at low altitude. Fifteen consenting adults scheduled to undergo general surgical/orthopaedic procedures under general anaesthesia using fentanyl, and propofol infusions titrated to the BIS along with nitrous oxide in oxygen after intubation, were recruited in the high-altitude arm. Their anaesthesia record was compared with retrospective data from low altitude with respect to anaesthetic requirements, recovery after anaesthesia and the haemodynamic responses to surgical stress. The high-altitude dwellers required significantly larger doses of propofol at anaesthetic induction (2.31+/-0.64 vs. 1.41+/-0.24 mg/kg, P<0.0001) and thereafter to maintain designated BIS than their low-altitude counterparts (6.22+/-1.14 vs. 4.61+/-1.29 mg/kg/h, P<0.01). They, however, had uneventful and short recovery times. The high-altitude population also had significantly lower baseline heart rates (72+/-9.83 vs. 88+/-12.1, P<0.04) as also the heart rate responses to noxious stimulation such as direct laryngoscopy or skin incision (P<0.04, P<0.005, respectively). High-altitude dwellers require significantly larger amounts of intravenous anaesthetic propofol. Heart rate at rest as also the heart rate responses to surgical stress were significantly attenuated at high altitude.

  5. Dynamic muscle O2 saturation response is impaired during major non-cardiac surgery despite goal-directed haemodynamic therapy.

    PubMed

    Feldheiser, A; Hunsicker, O; Kaufner, L; Köhler, J; Sieglitz, H; Casans Francés, R; Wernecke, K-D; Sehouli, J; Spies, C

    2016-03-01

    Near-infrared spectroscopy combined with a vascular occlusion test (VOT) could indicate an impairment of microvascular reactivity (MVR) in septic patients by detecting changes in dynamic variables of muscle O2 saturation (StO2). However, in the perioperative context the consequences of surgical trauma on dynamic variables of muscle StO2 as indicators of MVR are still unknown. This study is a sub-analysis of a randomised controlled trial in patients with metastatic primary ovarian cancer undergoing debulking surgery, during which a goal-directed haemodynamic algorithm was applied using oesophageal Doppler. During a 3 min VOT, near-infrared spectroscopy was used to assess dynamic variables arising from changes in muscle StO2. At the beginning of surgery, values of desaturation and recovery slope were comparable to values obtained in healthy volunteers. During the course of surgery, both desaturation and recovery slope showed a gradual decrease. Concomitantly, the study population underwent a transition to a surgically induced systemic inflammatory response state shown by a gradual increase in norepinephrine administration, heart rate, and Interleukin-6, with a peak immediately after the end of surgery. Higher rates of norepinephrine and a higher heart rate were related to a faster decline in StO2 during vascular occlusion. Using near-infrared spectroscopy combined with a VOT during surgery showed a gradual deterioration of MVR in patients treated with optimal haemodynamic care. The deterioration of MVR was accompanied by the transition to a surgically induced systemic inflammatory response state. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. LOSS OF BLOOD AT OPERATION—A Method for Continuous Measurement

    PubMed Central

    Borden, Fred W.

    1957-01-01

    A method for continuous measurement of surgical blood loss has been devised and has been used clinically in some 400 cases. The method combines volumetric measure of the suction loss and gravimetric measure of the sponge loss. The volumetric device automatically deducts the volume of rinse water used and thus measures the amount of blood collected in a metering cylinder. The suction loss scale shows continuously the amount of blood in the metering cylinder. The gravimetric device requires counting sponges into the weighing pan, and turning a dial scale to deduct the initial weight of the sponges. The volume of blood in the sponges is then read directly on the dial scale. Use of the instrument, which is under the supervision of the anesthesiologist, adds about two minutes per hour to the time normally required for counting the sponges; and about three minutes per hour is required for tending the volumetric instrument. In clinical use, knowing constantly the amount of blood loss permits the starting of transfusion before serious deficit develops, and then maintaining the patient's blood volume at a predetermined optimum level. In some 400 cases the continuous measurement of the blood loss served as a reliable guide for carrying out the loss-replacement plan within close limits of accuracy. ImagesFigure 2.p97-a PMID:13446754

  7. Consequences of nonclassical measurement for the algorithmic description of continuous dynamical systems

    NASA Technical Reports Server (NTRS)

    Fields, Chris

    1989-01-01

    Continuous dynamical systems intuitively seem capable of more complex behavior than discrete systems. If analyzed in the framework of the traditional theory of computation, a continuous dynamical system with countably many quasistable states has at least the computational power of a universal Turing machine. Such an analysis assumes, however, the classical notion of measurement. If measurement is viewed nonclassically, a continuous dynamical system cannot, even in principle, exhibit behavior that cannot be simulated by a universal Turing machine.

  8. Consequences of nonclassical measurement for the algorithmic description of continuous dynamical systems

    NASA Technical Reports Server (NTRS)

    Fields, Chris

    1989-01-01

    Continuous dynamical systems intuitively seem capable of more complex behavior than discrete systems. If analyzed in the framework of the traditional theory of computation, a continuous dynamical system with countablely many quasistable states has at least the computational power of a universal Turing machine. Such an analyses assumes, however, the classical notion of measurement. If measurement is viewed nonclassically, a continuous dynamical system cannot, even in principle, exhibit behavior that cannot be simulated by a universal Turing machine.

  9. CONTINUOUS, AUTOMATED AND SIMULTANEOUS MEASUREMENT OF OXYGEN UPTAKE AND CARBON DIOXIDE EVOLUTION IN BIOLOGICAL SYSTEMS

    EPA Science Inventory

    Commercial respirometers are capable of continuously and automatically measuring oxygen uptake in bioreactors. A method for continuously and automatically measuring carbon dioxide evolution can be retrofitted to commercial respirometers. Continuous and automatic measurements of...

  10. Multitime correlators in continuous measurement of qubit observables

    NASA Astrophysics Data System (ADS)

    Atalaya, Juan; Hacohen-Gourgy, Shay; Martin, Leigh S.; Siddiqi, Irfan; Korotkov, Alexander N.

    2018-02-01

    We consider multitime correlators for output signals from linear detectors, continuously measuring several qubit observables at the same time. Using the quantum Bayesian formalism, we show that for unital (symmetric) evolution in the absence of phase backaction, an N -time correlator can be expressed as a product of two-time correlators when N is even. For odd N , there is a similar factorization, which also includes a single-time average. Theoretical predictions agree well with experimental results for two detectors, which simultaneously measure noncommuting qubit observables.

  11. Exercise training improves peak oxygen consumption and haemodynamics in patients with severe pulmonary arterial hypertension and inoperable chronic thrombo-embolic pulmonary hypertension: a prospective, randomized, controlled trial

    PubMed Central

    Ehlken, Nicola; Lichtblau, Mona; Klose, Hans; Weidenhammer, Johannes; Fischer, Christine; Nechwatal, Robert; Uiker, Sören; Halank, Michael; Olsson, Karen; Seeger, Werner; Gall, Henning; Rosenkranz, Stephan; Wilkens, Heinrike; Mertens, Dirk; Seyfarth, Hans-Jürgen; Opitz, Christian; Ulrich, Silvia; Egenlauf, Benjamin; Grünig, Ekkehard

    2016-01-01

    Abstract Aims The impact of exercise training on the right heart and pulmonary circulation has not yet been invasively assessed in patients with pulmonary hypertension (PH) and right heart failure. This prospective randomized controlled study investigates the effects of exercise training on peak VO2/kg, haemodynamics, and further clinically relevant parameters in PH patients. Methods and results Eighty-seven patients with pulmonary arterial hypertension and inoperable chronic thrombo-embolic PH (54% female, 56 ± 15 years, 84% World Health Organization functional class III/IV, 53% combination therapy) on stable disease-targeted medication were randomly assigned to a control and training group. Medication remained unchanged during the study period. Non-invasive assessments and right heart catheterization at rest and during exercise were performed at baseline and after 15 weeks. Primary endpoint was the change in peak VO2/kg. Secondary endpoints included changes in haemodynamics. For missing data, multiple imputation and responder analyses were performed. The study results showed a significant improvement of peak VO2/kg in the training group (difference from baseline to 15 weeks: training +3.1 ± 2.7 mL/min/kg equals +24.3% vs. control −0.2 ± 2.3 mL/min/kg equals +0.9%, P < 0.001). Cardiac index (CI) at rest and during exercise, mean pulmonary arterial pressure, pulmonary vascular resistance, 6 min walking distance, quality of life, and exercise capacity significantly improved by exercise training. Conclusion Low-dose exercise training at 4–7 days/week significantly improved peak VO2/kg, haemodynamics, and further clinically relevant parameters. The improvements of CI at rest and during exercise indicate that exercise training may improve the right ventricular function. Further, large multicentre trials are necessary to confirm these results. PMID:26231884

  12. Determination of continuous variable entanglement by purity measurements.

    PubMed

    Adesso, Gerardo; Serafini, Alessio; Illuminati, Fabrizio

    2004-02-27

    We classify the entanglement of two-mode Gaussian states according to their degree of total and partial mixedness. We derive exact bounds that determine maximally and minimally entangled states for fixed global and marginal purities. This characterization allows for an experimentally reliable estimate of continuous variable entanglement based on measurements of purity.

  13. Venous haemodynamics of Jet Impulse Technology within a lower limb fibreglass cast: a randomized controlled trial.

    PubMed

    Braithwaite, Irene; Mackintosh, Stephen; Buchanan, Samantha; Schwarzenlander, Kerstin; De Ruyter, Bernadette

    2017-02-01

    We investigated popliteal venous haemodynamics of the VenaJet Jet Impulse Technology system within a below-knee fibreglass cast. Randomized controlled trial. Twenty-four healthy participants aged 18-54 had both feet placed within the Jet Impulse Technology system and were randomised for one or other leg to be within a below-knee fibreglass cast. Pacific Radiology, Lower Hutt, Wellington. The primary outcome variable was peak systolic velocity (cm/s) compared between legs with and without the cast at 60 min (after 10 min Jet Impulse Technology activation), using a mixed linear model and a non-inferiority bound of 4.8 cm/s. Secondary outcome variables were the difference in peak systolic velocity between the casted limb and the non-casted limb at baseline and 40 min after casting, and the difference in mean flow velocity (cm/s), vein diameter (mm), and total volume flow (L/min) between the casted limb and the non-casted limb at baseline, 40 and 60 min. The mean (standard deviation) peak systolic velocity was 4.6(1.5), 4.8(1.1), 28.8(16.1), and 4.3(1.2), 4.8(1.4) and 29.3(19.0) cm/s at baseline, 40 and 60 min in the casted and non-casted leg, respectively. The difference (95% confidence interval) between cast and no-cast at 60 min was -0.8 (-6.5 to 4.9) cm/s, P  = 0.78. The peak systolic velocity, flow velocity and total volume flow at 40 min were not statistically significantly different from baseline for both casted and non-casted limb. In healthy volunteers, the popliteal venous haemodynamics of the Jet Impulse Technology system was similar between the legs with and without a below-knee fibreglass cast. In-cast Jet Impulse Technology may provide a non-pharmacological option for venous thromboembolism prophylaxis for lower-limb cast-immobility.

  14. Comparing Measures of Voice Quality From Sustained Phonation and Continuous Speech.

    PubMed

    Gerratt, Bruce R; Kreiman, Jody; Garellek, Marc

    2016-10-01

    The question of what type of utterance-a sustained vowel or continuous speech-is best for voice quality analysis has been extensively studied but with equivocal results. This study examines whether previously reported differences derive from the articulatory and prosodic factors occurring in continuous speech versus sustained phonation. Speakers with voice disorders sustained vowels and read sentences. Vowel samples were excerpted from the steadiest portion of each vowel in the sentences. In addition to sustained and excerpted vowels, a 3rd set of stimuli was created by shortening sustained vowel productions to match the duration of vowels excerpted from continuous speech. Acoustic measures were made on the stimuli, and listeners judged the severity of vocal quality deviation. Sustained vowels and those extracted from continuous speech contain essentially the same acoustic and perceptual information about vocal quality deviation. Perceived and/or measured differences between continuous speech and sustained vowels derive largely from voice source variability across segmental and prosodic contexts and not from variations in vocal fold vibration in the quasisteady portion of the vowels. Approaches to voice quality assessment by using continuous speech samples average across utterances and may not adequately quantify the variability they are intended to assess.

  15. The influence of computational assumptions on analysing abdominal aortic aneurysm haemodynamics.

    PubMed

    Ene, Florentina; Delassus, Patrick; Morris, Liam

    2014-08-01

    The variation in computational assumptions for analysing abdominal aortic aneurysm haemodynamics can influence the desired output results and computational cost. Such assumptions for abdominal aortic aneurysm modelling include static/transient pressures, steady/transient flows and rigid/compliant walls. Six computational methods and these various assumptions were simulated and compared within a realistic abdominal aortic aneurysm model with and without intraluminal thrombus. A full transient fluid-structure interaction was required to analyse the flow patterns within the compliant abdominal aortic aneurysms models. Rigid wall computational fluid dynamics overestimates the velocity magnitude by as much as 40%-65% and the wall shear stress by 30%-50%. These differences were attributed to the deforming walls which reduced the outlet volumetric flow rate for the transient fluid-structure interaction during the majority of the systolic phase. Static finite element analysis accurately approximates the deformations and von Mises stresses when compared with transient fluid-structure interaction. Simplifying the modelling complexity reduces the computational cost significantly. In conclusion, the deformation and von Mises stress can be approximately found by static finite element analysis, while for compliant models a full transient fluid-structure interaction analysis is required for acquiring the fluid flow phenomenon. © IMechE 2014.

  16. Investigation of a continuous heating/cooling technique for cardiac output measurement.

    PubMed

    Ehlers, K C; Mylrea, K C; Calkins, J M

    1987-01-01

    Cardiac output is frequently measured to assess patient hemodynamic status in the operating room and intensive care unit. Current research for measuring cardiac output includes continuous sinusoidal heating and synchronous detection of thermal signals. This technique is limited by maximum heating element temperatures and background thermal noise. A continuous heating and cooling technique was investigated in vitro to determine if greater thermal signal magnitudes could be obtained. A fast responding thermistor was employed to measure consecutive ejected temperature plateaus in the thermal signal. A flow bath and mechanical ventricle were used to simulate the cardiovascular system. A thermoelectric module was used to apply heating and cooling energy to the flow stream. Trials encompassing a range of input power, input frequency, and flow rate were conducted. By alternating heating and cooling, thermal signal magnitude can be increased when compared to continuous heating alone. However, the increase was not sufficient to allow for recording in all patients over the expected normal range of cardiac output. Consecutive ejected temperature plateaus were also measured on the thermal signal and ejection fraction calculations were made.

  17. Correcting low-frequency noise with continuous measurement.

    PubMed

    Tian, L

    2007-04-13

    Low-frequency noise presents a serious source of decoherence in solid-state qubits. When combined with a continuous weak measurement of the eigenstates, low-frequency noise induces a second-order relaxation between the qubit states. Here, we show that the relaxation provides a unique approach to calibrate the low-frequency noise in the time domain. By encoding one qubit with two physical qubits that are alternatively calibrated, quantum-logic gates with high fidelity can be performed.

  18. Patient-specific CFD simulation of intraventricular haemodynamics based on 3D ultrasound imaging.

    PubMed

    Bavo, A M; Pouch, A M; Degroote, J; Vierendeels, J; Gorman, J H; Gorman, R C; Segers, P

    2016-09-09

    The goal of this paper is to present a computational fluid dynamic (CFD) model with moving boundaries to study the intraventricular flows in a patient-specific framework. Starting from the segmentation of real-time transesophageal echocardiographic images, a CFD model including the complete left ventricle and the moving 3D mitral valve was realized. Their motion, known as a function of time from the segmented ultrasound images, was imposed as a boundary condition in an Arbitrary Lagrangian-Eulerian framework. The model allowed for a realistic description of the displacement of the structures of interest and for an effective analysis of the intraventricular flows throughout the cardiac cycle. The model provides detailed intraventricular flow features, and highlights the importance of the 3D valve apparatus for the vortex dynamics and apical flow. The proposed method could describe the haemodynamics of the left ventricle during the cardiac cycle. The methodology might therefore be of particular importance in patient treatment planning to assess the impact of mitral valve treatment on intraventricular flow dynamics.

  19. Weak values in continuous weak measurements of qubits

    NASA Astrophysics Data System (ADS)

    Qin, Lupei; Liang, Pengfei; Li, Xin-Qi

    2015-07-01

    For continuous weak measurements of qubits, we obtain exact expressions for weak values (WVs) from the postselection restricted average of measurement outputs, by using both the quantum-trajectory equation (QTE) and the quantum Bayesian approach. The former is applicable to short-time weak measurement, while the latter can relax the measurement strength to finite. We find that even in the "very" weak limit the result can be essentially different from the one originally proposed by Aharonov, Albert, and Vaidman (AAV), in the sense that our result incorporates nonperturbative correction which could be important when the AAV WV is large. Within the Bayesian framework, we obtain also elegant expressions for finite measurement strength and find that the amplifier's noise in quantum measurement has no effect on the WVs. In particular, we obtain very useful results for homodyne measurement in a circuit-QED system, which allows for measuring the real and imaginary parts of the AAV WV by simply tuning the phase of the local oscillator. This advantage can be exploited as an efficient state-tomography technique.

  20. Haemodynamic improvement of older, previously replaced mechanical mitral valves by removal of the subvalvular pannus in redo cardiac surgery.

    PubMed

    Kim, Jong Hun; Kim, Tae Youn; Choi, Jong Bum; Kuh, Ja Hong

    2017-01-01

    Patients requiring redo cardiac surgery for diseased heart valves other than mitral valves may show increased pressure gradients and reduced valve areas of previously placed mechanical mitral valves due to subvalvular pannus formation. We treated four women who had mechanical mitral valves inserted greater than or equal to 20 years earlier and who presented with circular pannus that protruded into the lower margin of the valve ring but did not impede leaflet motion. Pannus removal improved the haemodynamic function of the mitral valve. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Safety and clinical effect of i.v. infusion of cyclopropyl-methoxycarbonyl etomidate (ABP-700), a soft analogue of etomidate, in healthy subjects.

    PubMed

    Valk, B I; Absalom, A R; Meyer, P; Meier, S; den Daas, I; van Amsterdam, K; Campagna, J A; Sweeney, S P; Struys, M M R F

    2018-06-01

    Cyclopropyl-methoxycarbonyl metomidate, or ABP-700, is a second generation analogue of etomidate, developed to retain etomidate's beneficial haemodynamic and respiratory profile but diminishing its suppression of the adrenocortical axis. The objective of this study was to characterise the safety and efficacy of 30-min continuous infusions of ABP-700, and to assess its effect on haemodynamics and the adrenocortical response in healthy human volunteers. Five cohorts involving 40 subjects received increasing infusion doses of ABP-700, propofol 60 μg kg -1  min -1 or placebo. Safety was evaluated through adverse event (AE) monitoring, safety laboratory tests, and arterial blood gasses. Haemodynamic and respiratory stability were assessed by continuous monitoring. Adrenocortical function was analysed by adrenocorticotropic hormone (ACTH) stimulation tests. Clinical effect was measured using the modified observer's assessment of alertness/sedation (MOAA/S) and continuous bispectral index monitoring. No serious AEs were reported. Haemodynamic and respiratory effects included mild dose-dependent tachycardia, slightly elevated blood pressure, and no centrally mediated apnoea. Upon stimulation with ACTH, no adrenocortical depression was observed in any subject. Involuntary muscle movements (IMM) were reported, which were more extensive with higher dosing regimens. Higher dosages of ABP-700 were associated with deeper sedation and increased likelihood of sedation. Time to onset of clinical effect was variable throughout the cohorts and recovery was swift. Infusions of ABP-700 showed a dose-dependent hypnotic effect, and did not cause severe hypotension, severe respiratory depression, or adrenocortical suppression. The presentation and nature of IMM is a matter of concern. NTR4735. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  2. Differential results integrated with continuous and discrete gravity measurements between nearby stations

    NASA Astrophysics Data System (ADS)

    Xu, Weimin; Chen, Shi; Lu, Hongyan

    2016-04-01

    Integrated gravity is an efficient way in studying spatial and temporal characteristics of the dynamics and tectonics. Differential measurements based on the continuous and discrete gravity observations shows highly competitive in terms of both efficiency and precision with single result. The differential continuous gravity variation between the nearby stations, which is based on the observation of Scintrex g-Phone relative gravimeters in every single station. It is combined with the repeated mobile relative measurements or absolute results to study the regional integrated gravity changes. Firstly we preprocess the continuous records by Tsoft software, and calculate the theoretical earth tides and ocean tides by "MT80TW" program through high precision tidal parameters from "WPARICET". The atmospheric loading effects and complex drift are strictly considered in the procedure. Through above steps we get the continuous gravity in every station and we can calculate the continuous gravity variation between nearby stations, which is called the differential continuous gravity changes. Then the differential results between related stations is calculated based on the repeated gravity measurements, which are carried out once or twice every year surrounding the gravity stations. Hence we get the discrete gravity results between the nearby stations. Finally, the continuous and discrete gravity results are combined in the same related stations, including the absolute gravity results if necessary, to get the regional integrated gravity changes. This differential gravity results is more accurate and effective in dynamical monitoring, regional hydrologic effects studying, tectonic activity and other geodynamical researches. The time-frequency characteristics of continuous gravity results are discussed to insure the accuracy and efficiency in the procedure.

  3. The Hölder continuity of spectral measures of an extended CMV matrix

    NASA Astrophysics Data System (ADS)

    Munger, Paul E.; Ong, Darren C.

    2014-09-01

    We prove results about the Hölder continuity of the spectral measures of the extended CMV matrix, given power law bounds of the solution of the eigenvalue equation. We thus arrive at a unitary analogue of the results of Damanik, Killip, and Lenz ["Uniform spectral properties of one-dimensional quasicrystals, III. α-continuity," Commun. Math. Phys. 212, 191-204 (2000)] about the spectral measure of the discrete Schrödinger operator.

  4. The Hölder continuity of spectral measures of an extended CMV matrix.

    PubMed

    Munger, Paul E; Ong, Darren C

    2014-09-01

    We prove results about the Hölder continuity of the spectral measures of the extended CMV matrix, given power law bounds of the solution of the eigenvalue equation. We thus arrive at a unitary analogue of the results of Damanik, Killip, and Lenz ["Uniform spectral properties of one-dimensional quasicrystals, III. α-continuity," Commun. Math. Phys.55, 191-204 (2000)] about the spectral measure of the discrete Schrödinger operator.

  5. Our Continuing Program of Optical Color Measurements of Centaurs and KBOs

    NASA Astrophysics Data System (ADS)

    Romanishin, W.; Tegler, S. C.; Consolmagno, G. J.

    2012-05-01

    We report on our continuing program of BVR color measurement of Centaurs and KBOs. Most of our measurements have been made with the Vatican Advanced Technology Telescope (VATT). We report of new colors obtained through October 2011.

  6. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    PubMed

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  7. Effects of peripheral cold application on core body temperature and haemodynamic parameters in febrile patients.

    PubMed

    Asgar Pour, Hossein; Yavuz, Meryem

    2014-04-01

    This study designed to assess the effects of peripheral cold application (PCA) on core body temperature and haemodynamic parameters in febrile patients. This study was an experimental, repeated-measures performed in the neurosurgical intensive-care unit. The research sample included all patients with fever in postoperative period. PCA was performed for 20 min. During fever, systolic blood pressure, mean arterial blood pressure and arterial oxygen saturation (O2 Sat) decreased by 5.07 ± 7.89 mm Hg, 0.191 ± 6.00 mm Hg and 0.742% ± 0.97%, respectively, whereas the pulse rate and diastolic blood pressure increased by 8.528 ± 4.42 beats/ min and 1.842 ± 6.9 mmHg, respectively. Immediately after PCA, core body temperature and pulse rate decreased by 0.3°C, 3.3 beats/min, respectively, whereas systolic, diastolic, mean arterial blood pressure and O2 Sat increased by, 1.40 mm Hg, 1.87 mm Hg, 0.98 mmHg and 0.27%, respectively. Thirty minutes after the end of PCA, core body temperature, diastolic, mean arterial blood pressure and pulse rate decreased by 0.57°C, 0.34 mm Hg, 0.60 mm Hg and 4.5 beats/min, respectively, whereas systolic blood pressure and O2 Sat increased by 0.98 mm Hg and 0.04%, respectively. The present results showed that PCA increases systolic, diastolic, mean arterial blood pressure and O2 Sat, and decreases core body temperature and pulse rate. © 2013 Wiley Publishing Asia Pty Ltd.

  8. Continuous measurements of nitrous oxide isotopomers during incubation experiments

    NASA Astrophysics Data System (ADS)

    Winther, Malte; Balslev-Harder, David; Christensen, Søren; Priemé, Anders; Elberling, Bo; Crosson, Eric; Blunier, Thomas

    2018-02-01

    Nitrous oxide (N2O) is an important and strong greenhouse gas in the atmosphere. It is produced by microbes during nitrification and denitrification in terrestrial and aquatic ecosystems. The main sinks for N2O are turnover by denitrification and photolysis and photo-oxidation in the stratosphere. In the linear N = N = O molecule 15N substitution is possible in two distinct positions: central and terminal. The respective molecules, 14N15N16O and 15N14N16O, are called isotopomers. It has been demonstrated that N2O produced by nitrifying or denitrifying microbes exhibits a different relative abundance of the isotopomers. Therefore, measurements of the site preference (difference in the abundance of the two isotopomers) in N2O can be used to determine the source of N2O, i.e., nitrification or denitrification. Recent instrument development allows for continuous position-dependent δ15N measurements at N2O concentrations relevant for studies of atmospheric chemistry. We present results from continuous incubation experiments with denitrifying bacteria, Pseudomonas fluorescens (producing and reducing N2O) and Pseudomonas chlororaphis (only producing N2O). The continuous measurements of N2O isotopomers reveals the transient isotope exchange among KNO3, N2O, and N2. We find bulk isotopic fractionation of -5.01 ‰ ± 1.20 for P. chlororaphis, in line with previous results for production from denitrification. For P. fluorescens, the bulk isotopic fractionation during production of N2O is -52.21 ‰ ± 9.28 and 8.77 ‰ ± 4.49 during N2O reduction.The site preference (SP) isotopic fractionation for P. chlororaphis is -3.42 ‰ ± 1.69. For P. fluorescens, the calculations result in SP isotopic fractionation values of 5.73 ‰ ± 5.26 during production of N2O and 2.41 ‰ ± 3.04 during reduction of N2O. In summary, we implemented continuous measurements of N2O isotopomers during incubation of denitrifying bacteria and believe that similar experiments will lead to a better

  9. Effects of scalp block with bupivacaine versus levobupivacaine on haemodynamic response to head pinning and comparative efficacies in postoperative analgesia: A randomized controlled trial.

    PubMed

    Can, Banu O; Bilgin, Hülya

    2017-04-01

    Objective This study was performed to determine the effects of scalp blocks with bupivacaine versus levobupivacaine on the haemodynamic response during craniotomy and the efficacies and analgesic requirements of these drugs postoperatively. Methods This randomized, prospective, placebo-controlled, double-blind study included 90 patients (age, 18-85 years; American Society of Anesthesiologists physical status, I or II). The patients were randomly divided into three groups: those who received 20 mL of 0.5% bupivacaine (Group B, n = 30), 20 mL of 0.5% levobupivacaine (Group L, n = 30), or saline as a placebo (Group C, n = 30). Scalp blocks were performed 5 min before head pinning. The primary outcome was the mean arterial pressure (MAP), and the secondary outcomes were the heart rate (HR), visual analogue scale (VAS) scores, and additional intraoperative and postoperative drug use. Postoperative pain was evaluated using a 10-cm VAS. Results During head pinning and incision, the MAP and HR were significantly higher in Group C. The additional drug requirement for intraoperative hypertension and tachycardia was significantly higher in Group C. There were no significant differences in MAP, HR, or VAS scores between Groups B and L. Conclusion Both bupivacaine and levobupivacaine can be effectively and safely used for scalp blocks to control haemodynamic responses and postoperative pain.

  10. The use of the oesophageal Doppler in perioperative medicine: new opportunities in research and clinical practice.

    PubMed

    Pinto, Bernardo Bollen; Atlas, Glen; Geerts, Bart F; Bendjelid, Karim

    2017-10-01

    The oesophageal Doppler (OD) is a minimally invasive haemodynamic monitor used in the surgical theatre and the ICU. Using the OD, goal-directed therapy (GDT) has been shown to reduce perioperative complications in high-risk surgical patients. However, most GDT protocols currently in use are limited to stroke volume optimisation. In the present manuscript, we examine the conceptual models behind new OD-based measurements. These would provide the clinician with a comprehensive view of haemodynamic pathophysiology; including pre-load, contractility, and afterload. Specifically, volume status could be estimated using mean systemic filling pressure (MSFP), the pressure to which all intravascular pressures equilibrate during asystole. Using the OD, MSFP could be readily estimated by simultaneous measurements of aortic blood flow and arterial pressure with sequential manoeuvres of increasing airway pressure. This would result in subsequent reductions in cardiac output and arterial pressure and would allow for a linear extrapolation of a static MSFP value to a "zero flow" state. In addition, we also demonstrate that EF is proportional to mean blood flow velocity measured in the descending thoracic aorta with the OD. Furthermore, OD-derived indexes of blood flow velocity and acceleration, as well as force and kinetic energy, can be derived and used for continuous assessment of cardiac contractility at the bedside. Using OD-derived parameters, the different components of afterload: inertia, resistance and elastance, could also be individually determined. The integration of these additional haemodynamic parameters could assist the clinician in optimising and individualising haemodynamic performance in unstable patients.

  11. Electrophysiological, haemodynamic, and mitochondrial alterations induced by levobupivacaine during myocardial ischemia in a pig model: protection by lipid emulsions?

    PubMed

    Mamou, Zahida; Descotes, Jacques; Chevalier, Philippe; Bui-Xuan, Bernard; Romestaing, Caroline; Timour, Quadiri

    2015-10-01

    Accidental intravascular or high-dose injection of local anesthetics (LA) can result in serious, potentially life-threatening complications. Indeed, adequate supportive measures and the administration of lipid emulsions are required in such complications. The study's objectives were threefold: (i) evaluate the myocardial toxicity of levobupivacaine when administered intravenously; (ii) investigate levobupivacaine toxicity on cardiomyocytes mitochondrial functions and cellular structure; (iii) assess the protective effects of a lipid emulsion in the presence or absence of myocardial ischemia. Domestic pigs randomized into two groups of 24 animals each, with either preserved coronary circulation or experimental myocardial ischemia. Six animals from each group received either: (i) single IV injection of saline, (ii) lipid emulsion (Intralipid(®) ), (iii) levobupivacaine, (iv) combination levobupivacaine-Intralipid(®) . Serially measured endpoints included: heart rate, duration of the monophasic action potentials (dMAP), mean arterial pressure, and peak of the time derivative of left ventricular pressure (LV dP/dtmax ). In addition, the following cardiomyocytes mitochondrial functions were measured: reactive oxygen species (ROS) production, oxidative phosphorylation, and calcium retention capacity (CRC) as well as the consequences of ROS production on lipids, proteins, and DNA. IV injection of levobupivacaine induced sinus bradycardia and reduced dMAP and LV dP/dtmax . At the mitochondrial level, oxygen consumption and CRC were decreased. In contrast, ROS production was increased leading to enhanced lipid peroxidation and structural alterations of proteins and DNA. Myocardial ischemia was associated with global worsening of all changes. Intralipid(®) quickly improved haemodynamics. However, beneficial effects of Intralipid(®) were less clear after myocardial ischemia. © 2015 Société Française de Pharmacologie et de Thérapeutique.

  12. Comparison of double intravenous vasopressor automated system using nexfin versus manual vasopressor bolus administration for maintenance of haemodynamic stability during spinal anaesthesia for caesarean delivery: A randomised double-blind controlled trial.

    PubMed

    Sng, Ban Leong; Du, Wei; Lee, Man Xin; Ithnin, Farida; Mathur, Deepak; Leong, Wan Ling; Sultana, Rehena; Han, Nian-Lin R; Sia, Alex Tiong Heng

    2018-05-01

    Hypotension is a common side effect of spinal anaesthesia during caesarean delivery and is associated with maternal and foetal adverse effects. We developed an updated double intravenous vasopressor automated (DIVA) system that administers phenylephrine or ephedrine based on continuous noninvasive haemodynamic monitoring using the Nexfin device. The aim of our present study is to compare the performance and reliability of the DIVA system against Manual Vasopressor Bolus administration. A randomised, double-blind controlled trial. Single-centre, KK Women's and Children's Hospital, Singapore. Two hundred and thirty-six healthy women undergoing elective caesarean delivery under spinal anaesthesia. The primary outcome was the incidence of maternal hypotension. The secondary outcome measures were reactive hypertension, total vasopressor requirement and maternal and neonatal outcomes. The DIVA group had a significantly lower incidence of maternal hypotension, with 39.3% (46 of 117) patients having any SBP reading less than 80% of baseline compared with 57.5% (65 of 113) in the manual vasopressor bolus group (P = 0.008). The DIVA group also had fewer hypotensive episodes than the manual vasopressor bolus group (4.67 versus 7.77%; P < 0.0001). There was no difference in the incidence of reactive hypertension or the total vasopressor requirement. The DIVA group had less wobble in system performance. Maternal and neonatal outcomes were similar. The DIVA system achieved better control of maternal blood pressure after spinal anaesthesia than manual vasopressor bolus administration. Clinicaltrials.gov identifier: NCT02277730.

  13. Multiple-frequency continuous wave ultrasonic system for accurate distance measurement

    NASA Astrophysics Data System (ADS)

    Huang, C. F.; Young, M. S.; Li, Y. C.

    1999-02-01

    A highly accurate multiple-frequency continuous wave ultrasonic range-measuring system for use in air is described. The proposed system uses a method heretofore applied to radio frequency distance measurement but not to air-based ultrasonic systems. The method presented here is based upon the comparative phase shifts generated by three continuous ultrasonic waves of different but closely spaced frequencies. In the test embodiment to confirm concept feasibility, two low cost 40 kHz ultrasonic transducers are set face to face and used to transmit and receive ultrasound. Individual frequencies are transmitted serially, each generating its own phase shift. For any given frequency, the transmitter/receiver distance modulates the phase shift between the transmitted and received signals. Comparison of the phase shifts allows a highly accurate evaluation of target distance. A single-chip microcomputer-based multiple-frequency continuous wave generator and phase detector was designed to record and compute the phase shift information and the resulting distance, which is then sent to either a LCD or a PC. The PC is necessary only for calibration of the system, which can be run independently after calibration. Experiments were conducted to test the performance of the whole system. Experimentally, ranging accuracy was found to be within ±0.05 mm, with a range of over 1.5 m. The main advantages of this ultrasonic range measurement system are high resolution, low cost, narrow bandwidth requirements, and ease of implementation.

  14. Haemodynamic Variations of Flow to Renal Arteries in Custom-Made and Pivot Branch Fenestrated Endografting.

    PubMed

    Ou, J; Tang, A Y S; Chiu, T L; Chow, K W; Chan, Y C; Cheng, S W K

    2017-01-01

    This study aimed to investigate variation of blood flow to renal arteries in custom-made and pivot branch (p-branch) fenestrated endografting, using a computational fluid dynamics (CFD) technique. Idealised models of custom-made and p-branch fenestrated grafting were constructed on a basis of a 26 mm stent graft. The custom-made fenestration was designed with a 6 mm diameter, while the 5 mm depth renal p-branch was created with a 6 mm inner and 15 mm outer fenestration. Two configurations (option A and option B) were constructed with different locations of p-branches. Option A had both renal p-branches at the same level, whereas option B contained two staggered p-branches at lower positions. The longitudinal stent orientation in both custom-made and p-branch models was represented by a takeoff angle (ToA) between the renal stent and distal stent graft centreline, varying from 55° to 125°. Computational simulations were performed with realistic boundary conditions governing the blood flow. In both custom-made and p-branch fenestrated models, the flow rate and wall shear stress (WSS) were generally higher and recirculation zones were smaller when the renal stent faced caudally. In custom-made models, the highest flow rate (0.390 L/min) was detected at 70° ToA and maximum WSS on vessel segment (16.8 Pa) was attained at 55° ToA. In p-branch models, option A and option B displayed no haemodynamic differences when having the same ToA. The highest flow rate (0.378 L/min) and maximum WSS on vessel segment (16.7 Pa) were both calculated at 55° ToA. The largest and smallest recirculation zones occurred at 90° and 55° ToA respectively in both custom-made and p-branch models. Custom-made fenestrated models exhibited consistently higher flow rate and shear stress and smaller recirculation zones in renal arteries than p-branch models at the same ToA. Navigating the renal stents towards caudal orientation can achieve better haemodynamic outcomes in both

  15. Continuous ammonia emission measurements from a commercial beef feedyard in Texas

    USDA-ARS?s Scientific Manuscript database

    Ambient NH3 concentrations were measured continuously at a beef cattle feedyard for 12 months beginning in March 2007. Concentrations were measured every five minutes, 24 hours per day, at a sample intake height of 3.3 m using a chemiluminescence analyzer. On-site weather data was collected concur...

  16. Improved formula for continuous-wave measurements of ultrasonic phase velocity

    NASA Technical Reports Server (NTRS)

    Chern, E. J.; Cantrell, J. H., Jr.; Heyman, J. S.

    1981-01-01

    An improved formula for continuous-wave ultrasonic phase velocity measurements using contact transducers is derived from the transmission line theory. The effect of transducer-sample coupling bonds is considered for measurements of solid samples even though it is often neglected because of the difficulty of accurately determining the bond thickness. Computer models show that the present formula is more accurate than previous expressions. Laboratory measurements using contacting transducers with the present formula are compared to measurements using noncontacting (hence effectively correction-free) capacitive transducers. The results of the experiments verify the validity and accuracy of the new formula.

  17. A continuous-wave ultrasound system for displacement amplitude and phase measurement.

    PubMed

    Finneran, James J; Hastings, Mardi C

    2004-06-01

    A noninvasive, continuous-wave ultrasonic technique was developed to measure the displacement amplitude and phase of mechanical structures. The measurement system was based on a method developed by Rogers and Hastings ["Noninvasive vibration measurement system and method for measuring amplitude of vibration of tissue in an object being investigated," U.S. Patent No. 4,819,643 (1989)] and expanded to include phase measurement. A low-frequency sound source was used to generate harmonic vibrations in a target of interest. The target was simultaneously insonified by a low-power, continuous-wave ultrasonic source. Reflected ultrasound was phase modulated by the target motion and detected with a separate ultrasonic transducer. The target displacement amplitude was obtained directly from the received ultrasound frequency spectrum by comparing the carrier and sideband amplitudes. Phase information was obtained by demodulating the received signal using a double-balanced mixer and low-pass filter. A theoretical model for the ultrasonic receiver field is also presented. This model coupled existing models for focused piston radiators and for pulse-echo ultrasonic fields. Experimental measurements of the resulting receiver fields compared favorably with theoretical predictions.

  18. Effect of Low (5 mg) vs. High (20-40 mg) Rosuvastatin Dose on 24h Arterial Stiffness, Central Haemodynamics, and Non-Alcoholic Fatty Liver Disease in Patients with Optimally Controlled Arterial Hypertension.

    PubMed

    Mitsiou, Eudoxia; Boutari, Chrysoula; Kotsis, Vasilios; Georgianou, Eleni; Doumas, Michael; Karagiannis, Asterios; Athyros, Vasilios G

    2018-01-01

    Arterial Stiffness (AS) and Non-Alcoholic Fatty Liver Diseases (NAFLD) are 2 related, prevalent, risk predictors of Cardiovascular Disease (CVD). We assessed the effect of low dose (5 mg/day) vs. high dose (20-40 mg/day) rosuvastatin on aortic elasticity and central haemodynamics as well as on NAFLD in patients with Arterial Hypertension (AH). Forty patients with optimally controlled AH were randomised to 2 rosuvastatin doses and followed for 6 months. 24h AS was assessed by Mobil-O-Graph, which calculates (adjusted for age and gender) Pulse Wave Velocity (PWV), adjusted for Heart Rate (HR) augmentation index (AIx75%) and central haemodynamics. The diagnosis of NAFLD was based on >5% liver steatosis on ultrasound and moderately elevated serum levels of liver enzymes. Both doses of rosuvastatin reduced Central Pulse Pressure (cPP), PWV and AIx75% (adjusted for HR) to normal values (p = NS adjusted for age, gender and HR). Liver enzymes were reduced in those with NAFLD to normal, but steatosis was reduced more by the 20-40 mg/day rosuvastatin dose (p=0.01) compared with the 5 mg/day dose. Both doses of rosuvastatin had a beneficial effect on AS; the high dose was more efficient in reducing PWVs and central haemodynamics, and also the high dose was more effective in ameliorating NAFLD. Given that AH control was optimal and lipid values attained targets, 4 other CVD predictors were also addressed. Larger and longer term studies are needed to demonstrate the clinical benefit of such treatment preference. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  19. Effects of organic and inorganic nitrate on aortic and carotid haemodynamics in heart failure with preserved ejection fraction.

    PubMed

    Chirinos, Julio A; Londono-Hoyos, Francisco; Zamani, Payman; Beraun, Melissa; Haines, Philip; Vasim, Izzah; Varakantam, Swapna; Phan, Timothy S; Cappola, Thomas P; Margulies, Kenneth B; Townsend, Raymond R; Segers, Patrick

    2017-11-01

    To assess the haemodynamic effects of organic vs. inorganic nitrate administration among patients with heart failure with preserved ejection fraction (HFpEF). We assessed carotid and aortic pressure-flow relations non-invasively before and after the administration of 0.4 mg of sublingual nitroglycerin (n = 26), and in a separate sub-study, in response to 12.9 mmoL of inorganic nitrate (n = 16). Nitroglycerin did not consistently reduce wave reflections arriving at the proximal aorta (change in real part of reflection coefficient, 1st harmonic: -0.09; P = 0.01; 2nd harmonic: -0.045, P = 0.16; 3rd harmonic: +0.087; P = 0.05), but produced profound vasodilatation in the carotid territory, with a significant reduction in systolic blood pressure (133.6 vs. 120.5 mmHg; P = 0.011) and a marked reduction in carotid bed vascular resistance (19 580 vs. 13 078 dynes · s/cm 5 ; P = 0.001) and carotid characteristic impedance (3440 vs. 1923 dynes · s/cm 5 ; P = 0.002). Inorganic nitrate, in contrast, consistently reduced wave reflections across the first three harmonics (change in real part of reflection coefficient, 1st harmonic: -0.12; P = 0.03; 2nd harmonic: -0.11, P = 0.01; 3rd harmonic: -0.087; P = 0.09) and did not reduce blood pressure, carotid bed vascular resistance, or carotid characteristic impedance (P = NS). Nitroglycerin produces marked vasodilatation in the carotid circulation, with a pronounced reduction in blood pressure and inconsistent effects on central wave reflections. Inorganic nitrate, in contrast, produces consistent reductions in wave reflections, and unlike nitroglycerin, it does so without significant hypotension or cerebrovascular dilatation. These haemodynamic differences may underlie the different effects on exercise capacity and side effect profile of inorganic vs. organic nitrate in HFpEF. © 2017 The Authors. European Journal of Heart Failure © 2017 European Society of Cardiology.

  20. Continuous infusion of antibiotics in critically ill patients.

    PubMed

    Smuszkiewicz, Piotr; Szałek, Edyta; Tomczak, Hanna; Grześkowiak, Edmund

    2013-02-01

    Antibiotics are the most commonly used drugs in intensive care unit patients and their supply should be based on pharmacokinetic/pharmacodynamic rules. The changes that occur in septic patients who are critically ill may be responsible for subtherapeutic antibiotic concentrations leading to poorer clinical outcomes. Evolving in time the disturbed pathophysiology in severe sepsis (high cardiac output, glomerular hyperfiltration) and therapeutic interventions (e.g. haemodynamically active drugs, mechanical ventilation, renal replacement therapy) alters antibiotic pharmacokinetics mainly through an increase in the volume of distribution and altered drug clearance. The lack of new and efficacious drugs and increased bacterial resistance are current problems of contemporary antibiotic therapy. Although intermittent administration is a standard clinical practice, alternative methods of antibiotic administration are sought, which may potentialise effects and reduce toxicity as well as contribute to inhibition of bacterial resistance. A wide range of studies prove that the application of continuous infusion of time-dependent antibiotics (beta-lactams, glycopeptides) is more rational than standard intermittent administration. However, there are also studies which do not confirm the advantage of one method over the other. In spite of controversy the continuous administration of this group of antibiotics is common practice, because the results of both studies point to the higher efficacy of this method in critically ill patients. Authors reviewed the literature to determine whether any clinical benefits exist for administration of time-dependent antibiotics by continuous infusion. Definite specification of the clinical advantage of administration this way over standard dosage requires a large-scale multi-centre randomised controlled trial.

  1. Effects of high-intensity interval training on central haemodynamics and skeletal muscle oxygenation during exercise in patients with chronic heart failure.

    PubMed

    Spee, Ruud F; Niemeijer, Victor M; Wijn, Pieter F; Doevendans, Pieter A; Kemps, Hareld M

    2016-12-01

    Background High-intensity interval training (HIT) improves exercise capacity in patients with chronic heart failure (CHF). Moreover, HIT was associated with improved resting cardiac function. However, the extent to which these improvements actually contribute to training-induced changes in exercise capacity remains to be elucidated. Therefore, we evaluated the effects of HIT on exercising central haemodynamics and skeletal muscle oxygenation. Methods Twenty-six CHF patients were randomised to a 12-week 4 × 4 minute HIT program at 85-95% of peak VO 2 or usual care. Patients performed maximal and submaximal cardiopulmonary exercise testing with simultaneous assessment of cardiac output and skeletal muscle oxygenation by near infrared spectroscopy, using the amplitude of the tissue saturation index (TSIamp). Results Peak workload increased by 11% after HIT ( p between group = 0.01) with a non-significant increase in peak VO 2 (+7%, p between group = 0.19). Cardiac reserve increased by 37% after HIT ( p within group = 0.03, p between group = 0.08); this increase was not related to improvements in peak workload. Oxygen uptake recovery kinetics after submaximal exercise were accelerated by 20% ( p between group = 0.02); this improvement was related to a decrease in TSIamp ( r = 0.71, p = 0.03), but not to changes in cardiac output kinetics. Conclusion HIT induced improvements in maximal exercise capacity and exercising haemodynamics at peak exercise. Improvements in recovery after submaximal exercise were associated with attenuated skeletal muscle deoxygenation during submaximal exercise, but not with changes in cardiac output kinetics, suggesting that the effect of HIT on submaximal exercise capacity is mediated by improved microvascular oxygen delivery-to-utilisation matching.

  2. Continuous quantum measurements and the action uncertainty principle

    NASA Astrophysics Data System (ADS)

    Mensky, Michael B.

    1992-09-01

    The path-integral approach to quantum theory of continuous measurements has been developed in preceding works of the author. According to this approach the measurement amplitude determining probabilities of different outputs of the measurement can be evaluated in the form of a restricted path integral (a path integral “in finite limits”). With the help of the measurement amplitude, maximum deviation of measurement outputs from the classical one can be easily determined. The aim of the present paper is to express this variance in a simpler and transparent form of a specific uncertainty principle (called the action uncertainty principle, AUP). The most simple (but weak) form of AUP is δ S≳ℏ, where S is the action functional. It can be applied for simple derivation of the Bohr-Rosenfeld inequality for measurability of gravitational field. A stronger (and having wider application) form of AUP (for ideal measurements performed in the quantum regime) is |∫{/' t″ }(δ S[ q]/δ q( t))Δ q( t) dt|≃ℏ, where the paths [ q] and [Δ q] stand correspondingly for the measurement output and for the measurement error. It can also be presented in symbolic form as Δ(Equation) Δ(Path) ≃ ℏ. This means that deviation of the observed (measured) motion from that obeying the classical equation of motion is reciprocally proportional to the uncertainty in a path (the latter uncertainty resulting from the measurement error). The consequence of AUP is that improving the measurement precision beyond the threshold of the quantum regime leads to decreasing information resulting from the measurement.

  3. Quantum cooling and squeezing of a levitating nanosphere via time-continuous measurements

    NASA Astrophysics Data System (ADS)

    Genoni, Marco G.; Zhang, Jinglei; Millen, James; Barker, Peter F.; Serafini, Alessio

    2015-07-01

    With the purpose of controlling the steady state of a dielectric nanosphere levitated within an optical cavity, we study its conditional dynamics under simultaneous sideband cooling and additional time-continuous measurement of either the output cavity mode or the nanosphere’s position. We find that the average phonon number, purity and quantum squeezing of the steady-states can all be made more non-classical through the addition of time-continuous measurement. We predict that the continuous monitoring of the system, together with Markovian feedback, allows one to stabilize the dynamics for any value of the laser frequency driving the cavity. By considering state of the art values of the experimental parameters, we prove that one can in principle obtain a non-classical (squeezed) steady-state with an average phonon number {n}{ph}≈ 0.5.

  4. Portable bioimpedance monitor evaluation for continuous impedance measurements. Towards wearable plethysmography applications.

    PubMed

    Ferreira, J; Seoane, F; Lindecrantz, K

    2013-01-01

    Personalised Health Systems (PHS) that could benefit the life quality of the patients as well as decreasing the health care costs for society among other factors are arisen. The purpose of this paper is to study the capabilities of the System-on-Chip Impedance Network Analyser AD5933 performing high speed single frequency continuous bioimpedance measurements. From a theoretical analysis, the minimum continuous impedance estimation time was determined, and the AD5933 with a custom 4-Electrode Analog Front-End (AFE) was used to experimentally determine the maximum continuous impedance estimation frequency as well as the system impedance estimation error when measuring a 2R1C electrical circuit model. Transthoracic Electrical Bioimpedance (TEB) measurements in a healthy subject were obtained using 3M gel electrodes in a tetrapolar lateral spot electrode configuration. The obtained TEB raw signal was filtered in MATLAB to obtain the respiration and cardiogenic signals, and from the cardiogenic signal the impedance derivative signal (dZ/dt) was also calculated. The results have shown that the maximum continuous impedance estimation rate was approximately 550 measurements per second with a magnitude estimation error below 1% on 2R1C-parallel bridge measurements. The displayed respiration and cardiac signals exhibited good performance, and they could be used to obtain valuable information in some plethysmography monitoring applications. The obtained results suggest that the AD5933-based monitor could be used for the implementation of a portable and wearable Bioimpedance plethysmograph that could be used in applications such as Impedance Cardiography. These results combined with the research done in functional garments and textile electrodes might enable the implementation of PHS applications in a relatively short time from now.

  5. Performance of Continuous CO2 Measurements in Soils: A Preliminary Assessment

    USDA-ARS?s Scientific Manuscript database

    Sensors for the continuous measurement of CO2 concentrations in soil are available but are not validated for real time, in situ measurement of CO2 in actively growing cropping systems. This study evaluated the Vaisala GM222 CO2 sensor over a range of soil conditions in the greenhouse and in the fiel...

  6. Continuous performance measurement in flight systems. [sequential control model

    NASA Technical Reports Server (NTRS)

    Connelly, E. M.; Sloan, N. A.; Zeskind, R. M.

    1975-01-01

    The desired response of many man machine control systems can be formulated as a solution to an optimal control synthesis problem where the cost index is given and the resulting optimal trajectories correspond to the desired trajectories of the man machine system. Optimal control synthesis provides the reference criteria and the significance of error information required for performance measurement. The synthesis procedure described provides a continuous performance measure (CPM) which is independent of the mechanism generating the control action. Therefore, the technique provides a meaningful method for online evaluation of man's control capability in terms of total man machine performance.

  7. Haemodynamic effects of vasoactive agents following chronic state of high cardiac output in anaesthetized rats.

    PubMed

    Guo, Liang; Tabrizchi, Reza

    2008-05-31

    The arteriovenous fistula model of circulation can produce a high output and low peripheral resistance situation. Here, we have examined the effects of noradrenaline, vasopressin and sodium nitroprusside on cardiac index, mean arterial blood pressure, venous tone, resistance to venous return, arterial resistance, and blood volume in chronically shunted anaesthetized rats. The cardiac index of rats with chronic arteriovenous fistula (AVF) was significantly higher (36.65+/-2.28 ml/min per 100 g; (mean+/-S.E.M.; n=24) in comparison to sham-operated rats (20.04+/-0.86 ml/min per 100 g; mean+/-S.E.M.; n=8). Cardiac index did not significantly change during the infusion of noradrenaline (1.0, 3.0 and 10 microg/kg per min), vasopressin (10, 30, 100 ng/kg per min) or sodium nitroprusside (0.1, 0.3 and 1.0 microg/kg per min) compared to saline infusion in AVF animals. Infusion of noradrenaline significantly increased heart rate, dP/dt, mean circulatory filling pressure (Pmcf) and resistance to venous return without affecting mean arterial blood pressure when compared to saline infusion. Administration of vasopressin significantly increased dP/dt, mean arterial blood pressure, and Pmcf without affecting heart rate, resistance to venous return or arterial resistance compared to saline infusion. Infusion of sodium nitroprusside did not significantly affect any haemodynamic parameter measured when compared to saline infusion. The results indicate that the presence of chronic AVF alters responsiveness of the various segments of the circulatory system to vasoactive agents. Moreover, it produces a major impediment to overall changes that can normally be induced following the infusion of such agents.

  8. Assessment of Portal Venous and Hepatic Artery Haemodynamic Variation in Non-Alcoholic Fatty Liver Disease (NAFLD) Patients.

    PubMed

    Balasubramanian, Padhmini; Boopathy, Vinoth; Govindasamy, Ezhumalai; Venkatesh, Basavaiya Prabhu

    2016-08-01

    Non-Alcoholic Fatty Liver Disease (NAFLD) has various spectrums of liver diseases like isolated fatty liver, steatohepatitis and cirrhosis usually progressing in a linear fashion. In this process they are known to cause certain haemodynamic changes in the portal flow and hepatic artery flow. The aim of the study was to study these haemodynamic changes in patients with NAFLD and to correlate it with the disease severity. Ninety patients diagnosed to have NAFLD based on ultrasound abdomen (30 each in grade1, grade2 and grade3 NAFLD) and 30 controls (Normal liver on ultrasound abdomen) were subjected to portal vein and hepatic artery Doppler study. Peak maximum velocity (Vmax), Peak minimum velocity (Vmin), Mean flow velocity (MFV), and Vein pulsality index (VPI) of the portal vein and hepatic artery resistivity index (HARI) of the hepatic artery were the doppler parameters which were assessed. Liver span was also assessed both for the fatty liver and controls. The mean Vmax, Vmin, MFV and VPI of the portal vein in patients with NAFLD was 12.23±1.74cm/sec, 9.31±1.45cm/sec, 10.76±1.48cm/sec, and 0.24±0.04 as compared to 14.05±2.43cm/sec, 10.01±2.27cm/sec, 12.23±2.47cm/sec, 0.3±0.08 in controls respectively. All these differences were statistically significant except for Vmin. The Mean HARI in patients with fatty liver was 0.65±0.06 when compared to controls of 0.75±0.06 (p=0.001). HARI (r-value of -0.517) had a better negative correlation followed by VPI (r-value of -0.44) and Vmax (r-value of -0.293) with the severity of NAFLD. MFV had a very weak negative correlation (r-value of -0.182) with the severity of NAFLD. The Vmax, MFV, VPI and HARI were significantly less when compared to controls suggesting a reduced portal flow and an increased hepatic arterial flow in patients with NAFLD. Among the parameters, HARI correlated better with the severity of NAFLD followed by VPI.

  9. Effects of 1:1, 1:2 or 1:3 intra-aortic balloon counterpulsation/heart support on coronary haemodynamics and cardiac contractile efficiency in an animal model of myocardial ischaemia/reperfusion.

    PubMed

    Gelsomino, Sandro; Renzulli, Attilio; Rubino, Antonino S; Romano, Salvatore Mario; Lucà, Fabiana; Valente, Serafina; Gensini, Gian Franco; Lorusso, Roberto

    2012-08-01

    The effects of operational modes of intra-aortic balloon pumping (IABP) on coronary haemodynamics and oxygen delivery/demand ratio are unknown and were investigated in an experimental model of myocardial ischaemia reperfusion. Healthy swine (n = 24) underwent 120-minute ligation of the left anterior descending coronary artery followed by 24 h of reperfusion and were randomly assigned to have IABP 1:1 (n = 6), IABP 1:2 (n = 6), IABP 1:3 (n = 6) in the descending aorta or to no IABP implantation (n = 6) 5 min after the onset of reperfusion. Systolic (CBF(Sys)) and diastolic (CBF(Dia)) coronary blood flow, systolic (CR(Sys)) and diastolic (CR(Dia)) coronary resistances and endocardial viability ratio (EVR), as an expression of the oxygen delivery/demand ratio, were measured at 30 min, 1, 6, 12 and 24 h after coronary reperfusion, respectively. IABP at the 1:1 operational mode significantly increased CBF(Dia) and EVR, and reduced CR(Dia) throughout the experiment. Contrastingly, IABP at 1:3 mode resulted in a significant reduction in CBF(Dia), in a steady increase in CR(Dia), in a steady reduction in O(2) delivery and a constant increase in O(2) demand over time. IABP at the 1:2 mode had no overall effect on assessed parameters. IABP at the 1:1 mode enhanced coronary haemodynamics and cardiac contractile efficiency in an acute animal model of coronary ischaemia/reperfusion. On the contrary, IABP support set at the 1:2 or 1:3 modes failed to provide benefit. Progressive reduction in balloon inflation with a 1:1 mode instead of decreasing the heart/IABP operational ratio might represent a better IABP withdrawal protocol and is currently under investigation.

  10. Acute haemodynamic effects of felodipine and verapamil in man, singly and with metoprolol.

    PubMed

    Rönn, O; Bengtsson, B; Edgar, B; Raner, S

    1985-01-01

    In a single-blind randomised study in 9 healthy men we compared the acute haemodynamic effects of the calcium antagonists felodipine and verapamil, singly and in combination with metoprolol. Three different cumulative intravenous doses of 0.25, 0.75 and 1.5 mg felodipine and of 2.0, 4.0 and 8.0 mg verapamil or placebo were given as constant infusions over 5 minutes on 3 occasions and were followed by intravenous metoprolol (15 mg). Felodipine caused a significant and dose-dependent decrease in the total peripheral resistance, and an increase in the forearm blood flow by 8, 48 and 163% with progressively increasing doses showing that the drug is a potent arteriolar vasodilator. A significant and dose-dependent increase in heart rate and a decrease in the pre-ejection period/left ventricular ejection time (PEP/LVET) ratio of up to 15% was also recorded, mainly reflecting a reflexogenic increase in the sympathetic tone. Total peripheral resistance, forearm blood flow, heart rate and the systolic time intervals were mainly unchanged after verapamil, whereas the PQ interval was prolonged. Metoprolol given after the 2 calcium antagonists caused a decrease in heart rate and blood flow and an increase in the total peripheral resistance and PEP/LVET ratio. The tolerability was good to all infusions.

  11. Continuous measurement of aortic dimensions in Turner syndrome: a cardiovascular magnetic resonance study.

    PubMed

    Subramaniam, Dhananjay Radhakrishnan; Stoddard, William A; Mortensen, Kristian H; Ringgaard, Steffen; Trolle, Christian; Gravholt, Claus H; Gutmark, Ephraim J; Mylavarapu, Goutham; Backeljauw, Philippe F; Gutmark-Little, Iris

    2017-02-24

    Severity of thoracic aortic disease in Turner syndrome (TS) patients is currently described through measures of aorta size and geometry at discrete locations. The objective of this study is to develop an improved measurement tool that quantifies changes in size and geometry over time, continuously along the length of the thoracic aorta. Cardiovascular magnetic resonance (CMR) scans for 15 TS patients [41 ± 9 years (mean age ± standard deviation (SD))] were acquired over a 10-year period and compared with ten healthy gender and age-matched controls. Three-dimensional aortic geometries were reconstructed, smoothed and clipped, which was followed by identification of centerlines and planes normal to the centerlines. Geometric variables, including maximum diameter and cross-sectional area, were evaluated continuously along the thoracic aorta. Distance maps were computed for TS and compared to the corresponding maps for controls, to highlight any asymmetry and dimensional differences between diseased and normal aortae. Furthermore, a registration scheme was proposed to estimate localized changes in aorta geometry between visits. The estimated maximum diameter from the continuous method was then compared with corresponding manual measurements at 7 discrete locations for each visit and for changes between visits. Manual measures at the seven positions and the corresponding continuous measurements of maximum diameter for all visits considered, correlated highly (R-value = 0.77, P < 0.01). There was good agreement between manual and continuous measurement methods for visit-to-visit changes in maximum diameter. The continuous method was less sensitive to inter-user variability [0.2 ± 2.3 mm (mean difference in diameters ± SD)] and choice of smoothing software [0.3 ± 1.3 mm]. Aortic diameters were larger in TS than controls in the ascending [TS: 13.4 ± 2.1 mm (mean distance ± SD), Controls: 12.6 ± 1 mm] and descending [TS

  12. Continuous measurements of bronchial exposure induced by radon decay products during inhalation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iwaoka, Kazuki; Tokonami, Shinji; Yonehara, Hidenori

    2007-09-15

    The deposition of radon decay products is not equal in each of the respiratory regions and as the presence of radon has been linked with an increase in lung cancer risk, it is important to calculate the deposition of radon decay products in each of the respiratory regions. Recently, many studies on the deposition of radon in respiratory regions have been simulated using wire screens. The systems and equipment used in those studies are not suitable for field measurements as their dimensions are relatively massive, nor can they measure continuously. We developed a continuous bronchial dosimeter (CBD) which is suitablemore » for field measurements. It was designed with specifications that allow it to be remain compact. The CBD simulates the deposition of radon decay products in the different respiratory regions by the use of a combination of wire screens. Deposition in the simulated regions of the lung can be continuously estimated in various environments. The ratio of activities deposited in a simulated nasal cavity (N) and tracheobronchial (TB) regions was calculated from the results of simultaneous measurements using CBD-R (reference), CBD-N (nasal), and CBD-TB (tracheobronchial) measurement units. After aerosols were injected into the radon chamber, the ratio of N and TB depositions decreased. This results indicate that the CBD gave a good response to changes in the environment. It was found that the ratio of N and TB deposition also varied with time in each actual environment.« less

  13. Measurement of complete and continuous Wigner functions for discrete atomic systems

    NASA Astrophysics Data System (ADS)

    Tian, Yali; Wang, Zhihui; Zhang, Pengfei; Li, Gang; Li, Jie; Zhang, Tiancai

    2018-01-01

    We measure complete and continuous Wigner functions of a two-level cesium atom in both a nearly pure state and highly mixed states. We apply the method [T. Tilma et al., Phys. Rev. Lett. 117, 180401 (2016), 10.1103/PhysRevLett.117.180401] of strictly constructing continuous Wigner functions for qubit or spin systems. We find that the Wigner function of all pure states of a qubit has negative regions and the negativity completely vanishes when the purity of an arbitrary mixed state is less than 2/3 . We experimentally demonstrate these findings using a single cesium atom confined in an optical dipole trap, which undergoes a nearly pure dephasing process. Our method can be applied straightforwardly to multi-atom systems for measuring the Wigner function of their collective spin state.

  14. Haemodynamic effects of umbilical cord milking in premature sheep during the neonatal transition.

    PubMed

    Blank, Douglas A; Polglase, Graeme R; Kluckow, Martin; Gill, Andrew William; Crossley, Kelly J; Moxham, Alison; Rodgers, Karyn; Zahra, Valerie; Inocencio, Ishmael; Stenning, Fiona; LaRosa, Domeic A; Davis, Peter G; Hooper, Stuart B

    2017-12-05

    Umbilical cord milking (UCM) at birth may benefit preterm infants, but the physiological effects of UCM are unknown. We compared the physiological effects of two UCM strategies with immediate umbilical cord clamping (UCC) and physiological-based cord clamping (PBCC) in preterm lambs. At 126 days' gestational age, fetal lambs were exteriorised, intubated and instrumented to measure umbilical, pulmonary and cerebral blood flows and arterial pressures. Lambs received either (1) UCM without placental refill (UCMwoPR); (2) UCM with placental refill (UCMwPR); (3) PBCC, whereby ventilation commenced prior to UCC; or (4) immediate UCC. UCM involved eight milks along a 10 cm length of cord, followed by UCC. A net volume of blood was transferred into the lamb during UCMwPR (8.8 mL/kg, IQR 8-10, P=0.01) but not during UCMwoPR (0 mL/kg, IQR -2.8 to 1.7) or PBCC (1.1 mL/kg, IQR -1.3 to 4.3). UCM had no effect on pulmonary blood flow, but caused large fluctuations in mean carotid artery pressures (MBP) and blood flows (CABF). In UCMwoPR and UCMwPR lambs, MBP increased by 12%±1% and 8%±1% and CABF increased by 32%±2% and 15%±2%, respectively, with each milk. Cerebral oxygenation decreased the least in PBCC lambs (17%, IQR 13-26) compared with UCMwoPR (26%, IQR 23-25, P=0.03), UCMwPR (35%, IQR 27-44, P=0.02) and immediate UCC (34%, IQR 28-41, P=0.02) lambs. UCMwoPR failed to provide placental transfusion, and UCM strategies caused considerable haemodynamic disturbance. UCM does not provide the same physiological benefits of PBCC. Further review of UCM is warranted before adoption into routine clinical practice. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Review of modern methods for continuous friction measurement on airfield pavements

    NASA Astrophysics Data System (ADS)

    Iwanowski, Paweł; Blacha, Krzysztof; Wesołowski, Mariusz

    2018-05-01

    The safety of traffic, including both road and air traffic on a ground manoeuvre area, depends on many factors. These mainly include the anti-slip properties of a road or airfield pavement on which the traffic takes place. The basic pavement parameter that determines its characteristics in terms of anti-slip properties is the skid resistance, which constitutes the ratio of the wheel downforce and the friction on the contact surface. There are currently many devices for continuous measurement of the skid resistance (Continuous Friction-Measuring Equipment - CFME) around the world. Most of them, in principle, do not vary much from one another. Most of the devices measure the measuring wheel’s downforce on the pavement and the friction on the wheel-pavement contact surface. The skid resistance is the result of this measurement. The devices vary in many aspects, such as the type and size of the used measuring tyre, pavement-wheel slip or tyre pressure. This does not mean that the results obtained from various devices mbe directly compared. On the other hand, each device allows determining the pavement’s anti-slip conditions in terms of the requirements specified for the given type of devices, thereby enabling pavement classification in these terms. The classification allows for comparing the results obtained from various measuring devices. The paper presents an overview of equipment used in Poland and around the world to measure the skid resistance on airfield pavements. The authors draw attention to the requirements for pavements in terms of their roughness, with division into road and airfield pavements.

  16. National Task Force on a Uniform Measurement Unit for the Recognition of Continuing Education: Working Papers; and The Continuing Education Unit: A Uniform Unit of Measure for Non-Credit Continuing Education Programs (An Interim Statement of the National Task Force).

    ERIC Educational Resources Information Center

    National Univ. Extension Association, Washington, DC.

    In 1968, a national planning conference, under the joint sponsorship of 34 organizations responsing to continuing education needs, created the National Task Force to determine the feasibility of a uniform unit of measurement and develop a proposal for field testing the concept. Stressing that continuing education units should supplement, not…

  17. CONTINUOUS FORMALDEHYDE MEASUREMENT SYSTEM BASED ON MODIFIED FOURIER TRANSFORM INFRARED SPECTROSCOPY

    EPA Science Inventory

    EPA is developing advanced open-path and cell-based optical techniques for time-resolved measurement of priority hazardous air pollutants such as formaldehyde (HCHO). Due to its high National Air Toxics Assessment risk factor, there is increasing interest in continuous measuremen...

  18. Prosthetists' perceptions and use of outcome measures in clinical practice: Long-term effects of focused continuing education.

    PubMed

    Hafner, Brian J; Spaulding, Susan E; Salem, Rana; Morgan, Sara J; Gaunaurd, Ignacio; Gailey, Robert

    2017-06-01

    Continuing education is intended to facilitate clinicians' skills and knowledge in areas of practice, such as administration and interpretation of outcome measures. To evaluate the long-term effect of continuing education on prosthetists' confidence in administering outcome measures and their perceptions of outcomes measurement in clinical practice. Pretest-posttest survey methods. A total of 66 prosthetists were surveyed before, immediately after, and 2 years after outcomes measurement education and training. Prosthetists were grouped as routine or non-routine outcome measures users, based on experience reported prior to training. On average, prosthetists were just as confident administering measures 1-2 years after continuing education as they were immediately after continuing education. In all, 20% of prosthetists, initially classified as non-routine users, were subsequently classified as routine users at follow-up. Routine and non-routine users' opinions differed on whether outcome measures contributed to efficient patient evaluations (79.3% and 32.4%, respectively). Both routine and non-routine users reported challenges integrating outcome measures into normal clinical routines (20.7% and 45.9%, respectively). Continuing education had a long-term impact on prosthetists' confidence in administering outcome measures and may influence their clinical practices. However, remaining barriers to using standardized measures need to be addressed to keep practitioners current with evolving practice expectations. Clinical relevance Continuing education (CE) had a significant long-term impact on prosthetists' confidence in administering outcome measures and influenced their clinical practices. In all, approximately 20% of prosthetists, who previously were non-routine outcome measure users, became routine users after CE. There remains a need to develop strategies to integrate outcome measurement into routine clinical practice.

  19. The Importance of and the Complexities Associated With Measuring Continuity of Care During Resident Training: Possible Solutions Do Exist.

    PubMed

    Carney, Patricia A; Conry, Colleen M; Mitchell, Karen B; Ericson, Annie; Dickinson, W Perry; Martin, James C; Carek, Peter J; Douglass, Alan B; Eiff, M Patrice

    2016-04-01

    Evolutions in care delivery toward the patient-centered medical home have influenced important aspects of care continuity. Primary responsibility for a panel of continuity patients is a foundational requirement in family medicine residencies. In this paper we characterize challenges in measuring continuity of care in residency training in this new era of primary care. We synthesized the literature and analyzed information from key informant interviews and group discussions with residency faculty and staff to identify the challenges and possible solutions for measuring continuity of care during family medicine training. We specifically focused on measuring interpersonal continuity at the patient level, resident level, and health care team level. Challenges identified in accurately measuring interpersonal continuity of care during residency training include: (1) variability in empanelment approaches for all patients, (2) scheduling complexity in different types of visits, (3) variability in ability to attain continuity counts at the level of the resident, and (4) shifting make-up of health care teams, especially in residency training. Possible solutions for each challenge are presented. Philosophical issues related to continuity are discussed, including whether true continuity can be achieved during residency training and whether qualitative rather than quantitative measures of continuity are better suited to residencies. Measuring continuity of care in residency training is challenging but possible, though improvements in precision and assessment of the comprehensive nature of the relationships are needed. Definitions of continuity during training and the role continuity measurement plays in residency need further study.

  20. WhiteRef: a new tower-based hyperspectral system for continuous reflectance measurements.

    PubMed

    Sakowska, Karolina; Gianelle, Damiano; Zaldei, Alessandro; MacArthur, Alasdair; Carotenuto, Federico; Miglietta, Franco; Zampedri, Roberto; Cavagna, Mauro; Vescovo, Loris

    2015-01-08

    Proximal sensing is fundamental to monitor the spatial and seasonal dynamics of ecosystems and can be considered as a crucial validation tool to upscale in situ observations to the satellite level. Linking hyperspectral remote sensing with carbon fluxes and biophysical parameters is critical to allow the exploitation of spatial and temporal extensive information for validating model simulations at different scales. In this study, we present the WhiteRef, a new hyperspectral system designed as a direct result of the needs identified during the EUROSPEC ES0903 Cost Action, and developed by Fondazione Edmund Mach and the Institute of Biometeorology, CNR, Italy. The system is based on the ASD FieldSpec Pro spectroradiometer and was designed to acquire continuous radiometric measurements at the Eddy Covariance (EC) towers and to fill a gap in the scientific community: in fact, no system for continuous spectral measurements in the Short Wave Infrared was tested before at the EC sites. The paper illustrates the functioning of the WhiteRef and describes its main advantages and disadvantages. The WhiteRef system, being based on a robust and high quality commercially available instrument, has a clear potential for unattended continuous measurements aiming at the validation of satellites' vegetation products.

  1. An alternative to traditional goodness-of-fit tests for discretely measured continuous data

    Treesearch

    KaDonna C. Randolph; Bill Seaver

    2007-01-01

    Traditional goodness-of-fit tests such as the Kolmogorov-Smirnov and x2 tests are easily applied to data of the continuous or discrete type, respectively. Occasionally, however, the case arises when continuous data are recorded into discrete categories due to an imprecise measurement system. In this instance, the traditional goodness-of-fit...

  2. SPH simulations of WBC adhesion to the endothelium: the role of haemodynamics and endothelial binding kinetics.

    PubMed

    Gholami, Babak; Comerford, Andrew; Ellero, Marco

    2015-11-01

    A multiscale Lagrangian particle solver introduced in our previous work is extended to model physiologically realistic near-wall cell dynamics. Three-dimensional simulation of particle trajectories is combined with realistic receptor-ligand adhesion behaviour to cover full cell interactions in the vicinity of the endothelium. The selected stochastic adhesion model, which is based on a Monte Carlo acceptance-rejection method, fits in our Lagrangian framework and does not compromise performance. Additionally, appropriate inflow/outflow boundary conditions are implemented for our SPH solver to enable realistic pulsatile flow simulation. The model is tested against in-vitro data from a 3D geometry with a stenosis and sudden expansion. In both steady and pulsatile flow conditions, results show close agreement with the experimental ones. Furthermore we demonstrate, in agreement with experimental observations, that haemodynamics alone does not account for adhesion of white blood cells, in this case U937 monocytic human cells. Our findings suggest that the current framework is fully capable of modelling cell dynamics in large arteries in a realistic and efficient manner.

  3. Achieving continuous improvement in laboratory organization through performance measurements: a seven-year experience.

    PubMed

    Salinas, Maria; López-Garrigós, Maite; Gutiérrez, Mercedes; Lugo, Javier; Sirvent, Jose Vicente; Uris, Joaquin

    2010-01-01

    Laboratory performance can be measured using a set of model key performance indicators (KPIs). The design and implementation of KPIs are important issues. KPI results from 7 years are reported and their implementation, monitoring, objectives, interventions, result reporting and delivery are analyzed. The KPIs of the entire laboratory process were obtained using Laboratory Information System (LIS) registers. These were collected automatically using a data warehouse application, spreadsheets and external quality program reports. Customer satisfaction was assessed using surveys. Nine model laboratory KPIs were proposed and measured. The results of some examples of KPIs used in our laboratory are reported. Their corrective measurements or the implementation of objectives led to improvement in the associated KPIs results. Measurement of laboratory performance using KPIs and a data warehouse application that continuously collects registers and calculates KPIs confirmed the reliability of indicators, indicator acceptability and usability for users, and continuous process improvement.

  4. Pharmacy claims data versus patient self-report to measure contraceptive method continuation.

    PubMed

    Triebwasser, Jourdan E; Higgins, Stephanie; Secura, Gina M; Zhao, Qiuhong; Peipert, Jeffrey F

    2015-07-01

    To compare self-reported 12-month continuation of oral contraceptive pills (OCPs), patch, and ring versus continuation by pharmacy claims data. Women in the Contraceptive CHOICE Project who chose OCPs, the patch, or the ring as their initial method were included. Continuation was assessed by periodic telephone survey and by obtaining prescription claims data. Continuation was defined as no gap of more than 30 days. Kaplan-Meier survival functions were used to estimate continuation rates and cumulative unintended pregnancy rates. Kappa statistic assessed the level of agreement between self-report and claims data. We analyzed 1510 women who initiated use by 3 months and provided information on discontinuation. Of OCP users, 59% continued their method at 12 months by self-report versus 38% by pharmacy claims. Patch and ring users had self-reported/pharmacy continuation of 45%/28% and 57%/37%, respectively. Kappa coefficients and their 95% confidence intervals between the two measurements were 0.46 (0.40, 0.52), 0.54 (0.39, 0.68), and 0.54 (0.47, 0.61) for OCP, patch, and ring, respectively. Among women who self-reported continuation, unintended pregnancy rates were 0.4% in those who continued by pharmacy claims versus 4.9% in those who discontinued according to claims data. Contraceptive continuation rates differ by self-report versus pharmacy claims with women overestimating their continuation by self-report. This article directly compares contraception continuation rates by self-report and by pharmacy claims data. The study suggests that previously reported continuation rates from survey data overestimate specific method use. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. [Continuous low volume infusion of hydroxyethyl starch as an option of water balance correction in patients with gestosis].

    PubMed

    Zhurova, A A; Ekstrem, A V; Popov, A S

    2010-01-01

    The method of long-term continuous low-volume infusion of hydroxyethyl starch (low-flow low volume correction HES) is administrated for correction of fluid balance disorders. The method is aimed to improve the outcomes in preeclamsia patients with multiple organ dysfunction and failure, as the most severe manifestation of system inflammatory response syndrome. After 4 days of the intensive care with application of the developed method in patients with preeclamsia the total body water level is decreased to the normal physiological level, the oedemas are significantly reduced or ceased, the haemodynamics stabilizes, which leads to the reduce of neurologic symptoms. The suggested method of low-flow low volume correction HES, in dose of 15 ml/kg/day is a significant addition to the existing methods of homeostasis and preeclampsia correction.

  6. Headset Bluetooth and cell phone based continuous central body temperature measurement system.

    PubMed

    Sanches, J Miguel; Pereira, Bruno; Paiva, Teresa

    2010-01-01

    The accurate measure of the central temperature is a very important physiologic indicator in several clinical applications, namely, in the characterization and diagnosis of sleep disorders. In this paper a simple system is described to continuously measure the body temperature at the ear. An electronic temperature sensor is coupled to the microphone of a common commercial auricular Bluetooth device that sends the temperature measurements to a mobile phone to which is paired. The measurements are stored at the mobile phone and periodically sent to a medical facility by email or SMS (short messaging service).

  7. Measuring Several Aspects of Attention in One Test: The Factor Structure of Conners's Continuous Performance Test

    ERIC Educational Resources Information Center

    Egeland, Jens; Kovalik-Gran, Iwona

    2010-01-01

    Objective: Continuous performance tests are known to typically measure sustained attention but usually also yield parameters that potentially measure other subprocesses of attention. The aim of the present study was to test the factor structure of the Conners's Continuous Performance Test (CCPT) in a heterogeneous clinical sample consisting of…

  8. Continuous odour measurement from fattening pig units

    NASA Astrophysics Data System (ADS)

    Romain, Anne-Claude; Nicolas, Jacques; Cobut, Pierre; Delva, Julien; Nicks, Baudouin; Philippe, François-Xavier

    2013-10-01

    A study in experimental slatted-system fattening pig units was conducted with the aim of estimating the odour emission factor (in ou s.pig-1), which can subsequently be used in dispersion models to assess the odour annoyance zone. Dynamic olfactometry measurements carried out at different development stages of pigs showed a logical trend of the mean assessed odour emission factor with the pig mass. However, the variation within the same mass class was much larger than variation between classes. Possible causes of such variation were identified as the evolution of ventilation rate during the day and the circadian rhythm of pig. To be able to monitor continuously the daily variation of the odour, an electronic nose was used with suitable regression model calibrated against olfactometric measurements. After appropriate validation check, the electronic nose proved to be convenient, as a complementary tool to dynamic olfactometry, to record the daily variation of the odour emission factor in the pig barn. It was demonstrated that, in the controlled conditions of the experimental pens, the daily variation of the odour emission rate could be mainly attributed to the sole influence of the circadian rhythm of pig. As a consequence, determining a representative odour emission factor in a real case cannot be based on a snapshot odour sampling.

  9. A continuous time-resolved measure decoded from EEG oscillatory activity predicts working memory task performance.

    PubMed

    Astrand, Elaine

    2018-06-01

    Working memory (WM), crucial for successful behavioral performance in most of our everyday activities, holds a central role in goal-directed behavior. As task demands increase, inducing higher WM load, maintaining successful behavioral performance requires the brain to work at the higher end of its capacity. Because it is depending on both external and internal factors, individual WM load likely varies in a continuous fashion. The feasibility to extract such a continuous measure in time that correlates to behavioral performance during a working memory task remains unsolved. Multivariate pattern decoding was used to test whether a decoder constructed from two discrete levels of WM load can generalize to produce a continuous measure that predicts task performance. Specifically, a linear regression with L2-regularization was chosen with input features from EEG oscillatory activity recorded from healthy participants while performing the n-back task, [Formula: see text]. The feasibility to extract a continuous time-resolved measure that correlates positively to trial-by-trial working memory task performance is demonstrated (r  =  0.47, p  <  0.05). It is furthermore shown that this measure allows to predict task performance before action (r  =  0.49, p  <  0.05). We show that the extracted continuous measure enables to study the temporal dynamics of the complex activation pattern of WM encoding during the n-back task. Specifically, temporally precise contributions of different spectral features are observed which extends previous findings of traditional univariate approaches. These results constitute an important contribution towards a wide range of applications in the field of cognitive brain-machine interfaces. Monitoring mental processes related to attention and WM load to reduce the risk of committing errors in high-risk environments could potentially prevent many devastating consequences or using the continuous measure as

  10. A continuous time-resolved measure decoded from EEG oscillatory activity predicts working memory task performance

    NASA Astrophysics Data System (ADS)

    Astrand, Elaine

    2018-06-01

    Objective. Working memory (WM), crucial for successful behavioral performance in most of our everyday activities, holds a central role in goal-directed behavior. As task demands increase, inducing higher WM load, maintaining successful behavioral performance requires the brain to work at the higher end of its capacity. Because it is depending on both external and internal factors, individual WM load likely varies in a continuous fashion. The feasibility to extract such a continuous measure in time that correlates to behavioral performance during a working memory task remains unsolved. Approach. Multivariate pattern decoding was used to test whether a decoder constructed from two discrete levels of WM load can generalize to produce a continuous measure that predicts task performance. Specifically, a linear regression with L2-regularization was chosen with input features from EEG oscillatory activity recorded from healthy participants while performing the n-back task, n\\in [1,2] . Main results. The feasibility to extract a continuous time-resolved measure that correlates positively to trial-by-trial working memory task performance is demonstrated (r  =  0.47, p  <  0.05). It is furthermore shown that this measure allows to predict task performance before action (r  =  0.49, p  <  0.05). We show that the extracted continuous measure enables to study the temporal dynamics of the complex activation pattern of WM encoding during the n-back task. Specifically, temporally precise contributions of different spectral features are observed which extends previous findings of traditional univariate approaches. Significance. These results constitute an important contribution towards a wide range of applications in the field of cognitive brain–machine interfaces. Monitoring mental processes related to attention and WM load to reduce the risk of committing errors in high-risk environments could potentially prevent many devastating consequences or

  11. Long-term non-invasive and continuous measurements of legume nodule activity.

    PubMed

    Cabeza, Ricardo A; Liese, Rebecca; Fischinger, Stephanie A; Sulieman, Saad; Avenhaus, Ulrike; Lingner, Annika; Hein, Hans; Koester, Beke; Baumgarten, Vanessa; Dittert, Klaus; Schulze, Joachim

    2015-02-01

    Symbiotic nitrogen fixation is a process of considerable economic, ecological and scientific interest. The central enzyme nitrogenase reduces H(+) alongside N2 , and the evolving H2 allows a continuous and non-invasive in vivo measurement of nitrogenase activity. The objective of this study was to show that an elaborated set-up providing such measurements for periods as long as several weeks will produce specific insight into the nodule activity's dependence on environmental conditions and genotype features. A system was developed that allows the air-proof separation of a root/nodule and a shoot compartment. H2 evolution in the root/nodule compartment can be monitored continuously. Nutrient solution composition, temperature, CO2 concentration and humidity around the shoots can concomitantly be maintained and manipulated. Medicago truncatula plants showed vigorous growth in the system when relying on nitrogen fixation. The set-up was able to provide specific insights into nitrogen fixation. For example, nodule activity depended on the temperature in their surroundings, but not on temperature or light around shoots. Increased temperature around the nodules was able to induce higher nodule activity in darkness versus light around shoots for a period of as long as 8 h. Conditions that affected the N demand of the shoots (ammonium application, Mg or P depletion, super numeric nodules) induced consistent and complex daily rhythms in nodule activity. It was shown that long-term continuous measurements of nodule activity could be useful for revealing special features in mutants and could be of importance when synchronizing nodule harvests for complex analysis of their metabolic status. © 2014 The Authors The Plant Journal © 2015 John Wiley & Sons Ltd.

  12. PGE2-EP2 signalling in endothelium is activated by haemodynamic stress and induces cerebral aneurysm through an amplifying loop via NF-κB

    PubMed Central

    Aoki, T; Nishimura, M; Matsuoka, T; Yamamoto, K; Furuyashiki, T; Kataoka, H; Kitaoka, S; Ishibashi, R; Ishibazawa, A; Miyamoto, S; Morishita, R; Ando, J; Hashimoto, N; Nozaki, K; Narumiya, S

    2011-01-01

    BACKGROUND AND PURPOSE Cerebral aneurysm is a frequent cerebrovascular event and a major cause of fatal subarachnoid haemorrhage, but there is no medical treatment for this condition. Haemodynamic stress and, recently, chronic inflammation have been proposed as major causes of cerebral aneurysm. Nevertheless, links between haemodynamic stress and chronic inflammation remain ill-defined, and to clarify such links, we evaluated the effects of prostaglandin E2 (PGE2), a mediator of inflammation, on the formation of cerebral aneurysms. EXPERIMENTAL APPROACH Expression of COX and prostaglandin E synthase (PGES) and PGE receptors were examined in human and rodent cerebral aneurysm. The incidence, size and inflammation of cerebral aneurysms were evaluated in rats treated with COX-2 inhibitors and mice lacking each prostaglandin receptor. Effects of shear stress and PGE receptor signalling on expression of pro-inflammatory molecules were studied in primary cultures of human endothelial cells (ECs). KEY RESULTS COX-2, microsomal PGES-1 and prostaglandin E receptor 2 (EP2) were induced in ECs in the walls of cerebral aneurysms. Shear stress applied to primary ECs induced COX-2 and EP2. Inhibition or loss of COX-2 or EP2in vivo attenuated each other's expression, suppressed nuclear factor κB (NF-κB)-mediated chronic inflammation and reduced incidence of cerebral aneurysm. EP2 stimulation in primary ECs induced NF-κB activation and expression of the chemokine (C-C motif) ligand 2, essential for cerebral aneurysm. CONCLUSIONS AND IMPLICATIONS These results suggest that shear stress activated PGE2-EP2 pathway in ECs and amplified chronic inflammation via NF-κB. We propose EP2 as a therapeutic target in cerebral aneurysm. PMID:21426319

  13. A Universal Noninvasive Continuous Blood Pressure Measurement System for Remote Healthcare Monitoring.

    PubMed

    Mukherjee, Ramtanu; Ghosh, Sanchita; Gupta, Bharat; Chakravarty, Tapas

    2018-01-22

    The effectiveness of any remote healthcare monitoring system depends on how much accurate, patient-friendly, versatile, and cost-effective measurement it is delivering. There has always been a huge demand for such a long-term noninvasive remote blood pressure (BP) measurement system, which could be used worldwide in the remote healthcare industry. Thus, noninvasive continuous BP measurement and remote monitoring have become an emerging area in the remote healthcare industry. Photoplethysmography-based (PPG) BP measurement is a continuous, unobtrusive, patient-friendly, and cost-effective solution. However, BP measurements through PPG sensors are not much reliable and accurate due to some major limitations like pressure disturbance, motion artifacts, and variations in human skin tone. A novel reflective PPG sensor has been developed to eliminate the abovementioned pressure disturbance and motion artifacts during the BP measurement. Considering the variations of the human skin tone across demography, a novel algorithm has been developed to make the BP measurement accurate and reliable. The training dataset captured 186 subjects' data and the trial dataset captured another new 102 subjects' data. The overall accuracy achieved by using the proposed method is nearly 98%. Thus, demonstrating the efficacy of the proposed method. The developed BP monitoring system is quite accurate, reliable, cost-effective, handy, and user friendly. It is also expected that this system would be quite useful to monitor the BP of infants, elderly people, patients having wounds, burn injury, or in the intensive care unit environment.

  14. Functional imaging of the human brain using a modular, fibre-less, high-density diffuse optical tomography system.

    PubMed

    Chitnis, Danial; Cooper, Robert J; Dempsey, Laura; Powell, Samuel; Quaggia, Simone; Highton, David; Elwell, Clare; Hebden, Jeremy C; Everdell, Nicholas L

    2016-10-01

    We present the first three-dimensional, functional images of the human brain to be obtained using a fibre-less, high-density diffuse optical tomography system. Our technology consists of independent, miniaturized, silicone-encapsulated DOT modules that can be placed directly on the scalp. Four of these modules were arranged to provide up to 128, dual-wavelength measurement channels over a scalp area of approximately 60 × 65 mm 2 . Using a series of motor-cortex stimulation experiments, we demonstrate that this system can obtain high-quality, continuous-wave measurements at source-detector separations ranging from 14 to 55 mm in adults, in the presence of hair. We identify robust haemodynamic response functions in 5 out of 5 subjects, and present diffuse optical tomography images that depict functional haemodynamic responses that are well-localized in all three dimensions at both the individual and group levels. This prototype modular system paves the way for a new generation of wearable, wireless, high-density optical neuroimaging technologies.

  15. Incorporating temporal and clinical reasoning in a new measure of continuity of care.

    PubMed Central

    Spooner, S. A.

    1994-01-01

    Previously described quantitative methods for measuring continuity of care have assumed that perfect continuity exists when a patient sees only one provider, regardless of the temporal pattern and clinical context of the visits. This paper describes an implementation of a new operational model of continuity--the Temporal Continuity Index--that takes into account time intervals between well visits in a pediatric residency continuity clinic. Ideal continuity in this model is achieved when intervals between visits are appropriate based on the age of the patient and clinical context of the encounters. The fundamental concept in this model is the expectation interval, which contains the length of the maximum ideal follow-up interval for a visit and the maximum follow-up interval. This paper describes an initial implementation of the TCI model and compares TCI calculations to previous quantitative methods and proposes its use as part of the assessment of resident education in outpatient settings. PMID:7950019

  16. Continuous high-frequency dissolved O2/Ar measurements by equilibrator inlet mass spectrometry.

    PubMed

    Cassar, Nicolas; Barnett, Bruce A; Bender, Michael L; Kaiser, Jan; Hamme, Roberta C; Tilbrook, Bronte

    2009-03-01

    The oxygen (O(2)) concentration in the surface ocean is influenced by biological and physical processes. With concurrent measurements of argon (Ar), which has similar solubility properties as oxygen, we can remove the physical contribution to O(2) supersaturation and determine the biological oxygen supersaturation. Biological O(2) supersaturation in the surface ocean reflects the net metabolic balance between photosynthesis and respiration, i.e., the net community productivity (NCP). We present a new method for continuous shipboard measurements of O(2)/Ar by equilibrator inlet mass spectrometry (EIMS). From these measurements and an appropriate gas exchange parametrization, NCP can be estimated at high spatial and temporal resolution. In the EIMS configuration, seawater from the ship's continuous intake flows through a cartridge enclosing a gas-permeable microporous membrane contactor. Gases in the headspace of the cartridge equilibrate with dissolved gases in the flowing seawater. A fused-silica capillary continuously samples headspace gases, and the O(2)/Ar ratio is measured by mass spectrometry. The ion current measurements on the mass spectrometer reflect the partial pressures of dissolved gases in the water flowing through the equilibrator. Calibration of the O(2)/Ar ion current ratio (32/40) is performed automatically every 2 h by sampling ambient air through a second capillary. A conceptual model demonstrates that the ratio of gases reaching the mass spectrometer is dependent on several parameters, such as the differences in molecular diffusivities and solubilities of the gases. Laboratory experiments and field observations performed by EIMS are discussed. We also present preliminary evidence that other gas measurements, such as N(2)/Ar and pCO(2) measurements, may potentially be performed with EIMS. Finally, we compare the characteristics of the EIMS with the previously described membrane inlet mass spectrometry (MIMS) approach.

  17. Mid-term haemodynamic and clinical results after aortic valve replacement using the Freedom Solo stentless bioprosthesis versus the Carpentier Edwards Perimount stented bioprosthesis.

    PubMed

    van der Straaten, Ellen P J; Rademakers, Leonard M; van Straten, Albert H M; Houterman, Saskia; Tan, M Erwin S H; Soliman Hamad, Mohamed A

    2016-04-01

    The aim of this study was to investigate the mid-term haemodynamic and clinical results after aortic valve replacement (AVR) using the Sorin Freedom Solo (SFS) stentless bioprosthesis, compared with the standard Carpentier Edwards Perimount (CEP) stented bioprosthesis. In this retrospective cohort study of prospectively collected data, 116 patients were included in the SFS group (53 males; median age 74 years, range 56-85 years), and 122 patients in the CEP group (85 males; median age 73 years, range 43-88 years) between July 2007 and January 2013. Echocardiography was performed at 6 weeks after surgery in our centre, and the most recent echocardiography (in our centre or in referring cardiology departments) was requested. Between September 2013 and April 2014, all patients were called by the same researcher to gain clinical follow-up data. Mid-term mortality was 16.4% in the SFS group (19 patients) and 21.3% in the CEP group (26 patients); (P = 0.3). The mean transvalvular gradient was 7.4 ± 3.1 mmHg in the SFS group, and 11.6 ± 3.2 mmHg in the CEP group at 6 weeks postoperatively (P < 0.001). When stratified by labelled valve size, mean gradients were significantly lower in the SFS group for every size (P ≤ 0.03). After 3.3 ± 1.4 years of follow-up, the mean gradient was still significantly lower in the SFS group than that in the CEP group (P < 0.001). Clinical follow-up showed relatively low complication rates. These data suggest that the Sorin Freedom Solo stentless bioprosthesis is as safe as the Carpentier Edwards bioprosthesis, and provides better short- and mid-term haemodynamic performance than the Carpentier Edwards bioprosthesis. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. Using continuous in-situ measurements to adaptively trigger urban storm water samples

    NASA Astrophysics Data System (ADS)

    Wong, B. P.; Kerkez, B.

    2015-12-01

    Until cost-effective in-situ sensors are available for biological parameters, nutrients and metals, automated samplers will continue to be the primary source of reliable water quality measurements. Given limited samples bottles, however, autosamplers often obscure insights on nutrient sources and biogeochemical processes which would otherwise be captured using a continuous sampling approach. To that end, we evaluate the efficacy a novel method to measure first-flush nutrient dynamics in flashy, urban watersheds. Our approach reduces the number of samples required to capture water quality dynamics by leveraging an internet-connected sensor node, which is equipped with a suite of continuous in-situ sensors and an automated sampler. To capture both the initial baseflow as well as storm concentrations, a cloud-hosted adaptive algorithm analyzes the high-resolution sensor data along with local weather forecasts to optimize a sampling schedule. The method was tested in a highly developed urban catchment in Ann Arbor, Michigan and collected samples of nitrate, phosphorus, and suspended solids throughout several storm events. Results indicate that the watershed does not exhibit first flush dynamics, a behavior that would have been obscured when using a non-adaptive sampling approach.

  19. Constraints on dike propagation from continuous GPS measurements

    NASA Astrophysics Data System (ADS)

    Segall, Paul; Cervelli, Peter; Owen, Susan; Lisowski, Mike; Miklius, Asta

    2001-09-01

    The January 1997 East Rift Zone eruption on Kilauea volcano, Hawaii, occurred within a network of continuous Global Positioning System (GPS) receivers. The GPS measurements reveal the temporal history of deformation during dike intrusion, beginning ˜8 hours prior to the onset of the eruption. The dike volume as a function of time, estimated from the GPS data using elastic Green's functions for a homogeneous half-space, shows that only two thirds of the final dike volume accumulated prior to the eruption and the rate of volume change decreased with time. These observations are inconsistent with simple models of dike propagation, which predict accelerating dike volume up to the time of the eruption and little or no change thereafter. Deflationary tilt changes at Kilauea summit mirror the inferred dike volume history, suggesting that the rate of dike propagation is limited by flow of magma into the dike. A simple, lumped parameter model of a coupled dike magma chamber system shows that the tendency for a dike to end in an eruption (rather than intrusion) is favored by high initial dike pressures, compressional stress states, large, compressible magma reservoirs, and highly conductive conduits linking the dike and source reservoirs. Comparison of model predictions to the observed dike volume history, the ratio of erupted to intruded magma, and the deflationary history of the summit magma chamber suggest that most of the magma supplied to the growing dike came from sources near to the eruption through highly conductive conduits. Interpretation is complicated by the presence of multiple source reservoirs, magma vesiculation and cooling, as well as spatial variations in dike-normal stress. Reinflation of the summit magma chamber following the eruption was measured by GPS and accompanied a rise in the level of the Pu'u O'o lava lake. For a spheroidal chamber these data imply a summit magma chamber volume of ˜20 km3, consistent with recent estimates from seismic

  20. Constraints on dike propagation from continuous GPS measurements

    USGS Publications Warehouse

    Segall, P.; Cervelli, Peter; Owen, S.; Lisowski, M.; Miklius, Asta

    2001-01-01

    The January 1997 East Rift Zone eruption on Kilauea volcano, Hawaii, occurred within a network of continuous Global Positioning System (GPS) receivers. The GPS measurements reveal the temporal history of deformation during dike intrusion, beginning ??? 8 hours prior to the onset of the eruption. The dike volume as a function of time, estimated from the GPS data using elastic Green's functions for a homogeneous half-space, shows that only two thirds of the final dike volume accumulated prior to the eruption and the rate of volume change decreased with time. These observations are inconsistent with simple models of dike propagation, which predict accelerating dike volume up to the time of the eruption and little or no change thereafter. Deflationary tilt changes at Kilauea summit mirror the inferred dike volume history, suggesting that the rate of dike propagation is limited by flow of magma into the dike. A simple, lumped parameter model of a coupled dike magma chamber system shows that the tendency for a dike to end in an eruption (rather than intrusion) is favored by high initial dike pressures, compressional stress states, large, compressible magma reservoirs, and highly conductive conduits linking the dike and source reservoirs. Comparison of model predictions to the observed dike volume history, the ratio of erupted to intruded magma, and the deflationary history of the summit magma chamber suggest that most of the magma supplied to the growing dike came from sources near to the eruption through highly conductive conduits. Interpretation is complicated by the presence of multiple source reservoirs, magma vesiculation and cooling, as well as spatial variations in dike-normal stress. Reinflation of the summit magma chamber following the eruption was measured by GPS and accompanied a rise in the level of the Pu'u O'o lava lake. For a spheroidal chamber these data imply a summit magma chamber volume of ??? 20 km3, consistent with recent estimates from seismic

  1. Continuous wave cavity ring-down spectroscopy for velocity distribution measurements in plasma.

    PubMed

    McCarren, D; Scime, E

    2015-10-01

    We report the development of a continuous wave cavity ring-down spectroscopic (CW-CRDS) diagnostic for real-time, in situ measurement of velocity distribution functions of ions and neutral atoms in plasma. This apparatus is less complex than conventional CW-CRDS systems. We provide a detailed description of the CW-CRDS apparatus as well as measurements of argon ions and neutrals in a high-density (10(9) cm(-3) < plasma density <10(13) cm(-3)) plasma. The CW-CRDS measurements are validated through comparison with laser induced fluorescence measurements of the same absorbing states of the ions and neutrals.

  2. Measuring patient-centered medical home access and continuity in clinics with part-time clinicians.

    PubMed

    Rosland, Ann-Marie; Krein, Sarah L; Kim, Hyunglin Myra; Greenstone, Clinton L; Tremblay, Adam; Ratz, David; Saffar, Darcy; Kerr, Eve A

    2015-05-01

    Common patient-centered medical home (PCMH) performance measures value access to a single primary care provider (PCP), which may have unintended consequences for clinics that rely on part-time PCPs and team-based care. Retrospective analysis of 110,454 primary care visits from 2 Veterans Health Administration clinics from 2010 to 2012. Multi-level models examined associations between PCP availability in clinic, and performance on access and continuity measures. Patient experiences with access and continuity were compared using 2012 patient survey data (N = 2881). Patients of PCPs with fewer half-day clinic sessions per week were significantly less likely to get a requested same-day appointment with their usual PCP (predicted probability 17% for PCPs with 2 sessions/week, 20% for 5 sessions/week, and 26% for 10 sessions/week). Among requests that did not result in a same-day appointment with the usual PCP, there were no significant differences in same-day access to a different PCP, or access within 2 to 7 days with patients' usual PCP. Overall, patients had >92% continuity with their usual PCP at the hospital-based site regardless of PCP sessions/week. Patients of full-time PCPs reported timely appointments for urgent needs more often than patients of part-time PCPs (82% vs 71%; P < .01), but reported similar experiences with routine access and continuity. Part-time PCP performance appeared worse when using measures focused on same-day access to patients' usual PCP. However, clinic-level same-day access, same-week access to the usual PCP, and overall continuity were similar for patients of part-time and full-time PCPs. Measures of in-person access to a usual PCP do not capture alternate access approaches encouraged by PCMH, and often used by part-time providers, such as team-based or non-face-to-face care.

  3. Continuous Measurement of Methane Ebullition Flux from a Northern Peatland using a Fast Methane Analyzer

    NASA Astrophysics Data System (ADS)

    Zhongjie, Y.; Schafer, K. V.; Slater, L. D.; Varner, R. K.; Amante, J.; Comas, X.; Reeve, A. S.; Alcivar, W.; Gonzalez, D.

    2012-12-01

    Northern peatlands are an important source of methane (CH4) release to the atmosphere, estimated at between 20 and 50 Tg/yr. Recent work on CH4 emissions from peatlands has demonstrated that ebullition can be a more important emission pathway than previously assumed. However, accurate quantification of the atmospheric CH4 burden due to ebullition is still very limited because ebullition exhibits high spatiotemporal variability such that sudden episodic events are difficult to capture and quantify with existing experimental methods. We have initiated a novel measurement program to better quantify the spatiotemporal variability in CH4 flux in peatlands, and to examine potential effects of vegetation and environmental factors, e.g. atmospheric pressure, water table, etc on these releases. A flow-through system was designed, consisting of a closed static chamber and a fast methane analyzer (FMA) (LI-COR model 7700) that has been employed at both the field and laboratory scale. The CH4 concentration in the air flowing through the chamber is continuously measured by the analyzer and used to reconstruct continuous CH4 emission fluxes. The high sampling rate of the FMA makes it sensitive to both ebullition and diffusion of gaseous CH4, capturing short duration, episodic ebullition fluxes. Non-steady static chamber measurements were also conducted to cross-validate the continuous measurements. Results acquired during summer 2011 show that episodic ebullition occurred more frequently at the pool site where previous studies indicate extensive wood layers at depth and the vegetation was a mix of Sphagnum and wooded heath. During a 3 day period of continuous measurements captured the passage of a tropical storm Irene, where short term episodic releases of CH4, ranging from 113 mg CH4/m2/d to 202 mg CH4/m2/d, were observed at the time of lowest atmospheric pressure, providing new evidence that atmospheric pressure is an important factor to controlling CH4 ebullition from

  4. Measurement of the refractive index of hemoglobin solutions for a continuous spectral region

    PubMed Central

    Wang, Jin; Deng, Zhichao; Wang, Xiaowan; Ye, Qing; Zhou, Wenyuan; Mei, Jianchun; Zhang, Chunping; Tian, Jianguo

    2015-01-01

    Determination of the refractive index of hemoglobin solutions over a wide wavelength range remains challenging. A famous detour approach is the Kramers-Kronig (KK) analysis which can resolve the real part of complex refractive index from the imaginary part. However, KK analysis is limited by the contradiction between the requirement of semi-infinite frequency range and limited measured range. In this paper, based on the Multi-curve fitting method (MFM), continuous refractive index dispersion (CRID) of oxygenated and deoxygenated hemoglobin solutions are measured using a homemade symmetrical arm-linked apparatus in the continuous wavelength range with spectral resolution of about 0.259nm. A novel method to obtain the CRID is proposed. PMID:26203379

  5. Continuity of care in mental health: understanding and measuring a complex phenomenon.

    PubMed

    Burns, T; Catty, J; White, S; Clement, S; Ellis, G; Jones, I R; Lissouba, P; McLaren, S; Rose, D; Wykes, T

    2009-02-01

    Continuity of care is considered by patients and clinicians an essential feature of good quality care in long-term disorders, yet there is general agreement that it is a complex concept. Most policies emphasize it and encourage systems to promote it. Despite this, there is no accepted definition or measure against which to test policies or interventions designed to improve continuity. We aimed to operationalize a multi-axial model of continuity of care and to use factor analysis to determine its validity for severe mental illness. A multi-axial model of continuity of care comprising eight facets was operationalized for quantitative data collection from mental health service users using 32 variables. Of these variables, 22 were subsequently entered into a factor analysis as independent components, using data from a clinical population considered to require long-term consistent care. Factor analysis produced seven independent continuity factors accounting for 62.5% of the total variance. These factors, Experience and Relationship, Regularity, Meeting Needs, Consolidation, Managed Transitions, Care Coordination and Supported Living, were close but not identical to the original theoretical model. We confirmed that continuity of care is multi-factorial. Our seven factors are intuitively meaningful and appear to work in mental health. These factors should be used as a starting-point in research into the determinants and outcomes of continuity of care in long-term disorders.

  6. Continuous Faraday measurement of spin precession without light shifts

    NASA Astrophysics Data System (ADS)

    Jasperse, M.; Kewming, M. Â. J.; Fischer, S. Â. N.; Pakkiam, P.; Anderson, R. Â. P.; Turner, L. Â. D.

    2017-12-01

    We describe a dispersive Faraday optical probe of atomic spin which performs a weak measurement of spin projection of a quantum gas continuously for more than one second. To date, focusing bright far-off-resonance probes onto quantum gases has proved invasive due to strong scalar and vector light shifts exerting dipole and Stern-Gerlach forces. We show that tuning the probe near the magic-zero wavelength at 790 nm between the fine-structure doublet of 87Rb cancels the scalar light shift, and careful control of polarization eliminates the vector light shift. Faraday rotations due to each fine-structure line reinforce at this wavelength, enhancing the signal-to-noise ratio for a fixed rate of probe-induced decoherence. Using this minimally invasive spin probe, we perform microscale atomic magnetometry at high temporal resolution. Spectrogram analysis of the Larmor precession signal of a single spinor Bose-Einstein condensate measures a time-varying magnetic field strength with 1 μ G accuracy every 5 ms; or, equivalently, makes more than 200 successive measurements each at 10 pT /√{Hz } sensitivity.

  7. Effect of Fontan geometry on exercise haemodynamics and its potential implications.

    PubMed

    Tang, Elaine; Wei, Zhenglun Alan; Whitehead, Kevin K; Khiabani, Reza H; Restrepo, Maria; Mirabella, Lucia; Bethel, James; Paridon, Stephen M; Marino, Bradley S; Fogel, Mark A; Yoganathan, Ajit P

    2017-11-01

    Exercise intolerance afflicts Fontan patients with total cavopulmonary connections (TCPCs) causing a reduction in quality of life. Optimising TCPC design is hypothesised to have a beneficial effect on exercise capacity. This study investigates relationships between TCPC geometries and exercise haemodynamics and performance. This study included 47 patients who completed metabolic exercise stress test with cardiac magnetic resonance (CMR). Phase-contrast CMR images were acquired immediately following supine lower limb exercise. Both anatomies and exercise vessel flow rates at ventilatory anaerobic threshold (VAT) were extracted. The vascular modelling toolkits were used to analyse TCPC geometries. Computational simulations were performed to quantify TCPC indexed power loss (iPL) at VAT. A highly significant inverse correlation was found between the TCPC diameter index, which factors in the narrowing of TCPC vessels, with iPL at VAT (r=-0.723, p<0.001) but positive correlations with exercise performance variables, including minute oxygen consumption (VO 2 ) at VAT (r=0.373, p=0.01), VO 2 at peak exercise (r=0.485, p=0.001) and work at VAT/weight (r=0.368, p=0.01). iPL at VAT was negatively correlated with VO 2 at VAT (r=-0.337, p=0.02), VO 2 at peak exercise (r=-0.394, p=0.007) and work at VAT/weight (r=-0.208, p=0.17). Eliminating vessel narrowing in TCPCs and reducing elevated iPL at VAT could enhance exercise tolerance for patients with TCPCs. These findings could help plan surgical or catheter-based strategies to improve patients' exercise capacity. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Fault-tolerant measurement-based quantum computing with continuous-variable cluster states.

    PubMed

    Menicucci, Nicolas C

    2014-03-28

    A long-standing open question about Gaussian continuous-variable cluster states is whether they enable fault-tolerant measurement-based quantum computation. The answer is yes. Initial squeezing in the cluster above a threshold value of 20.5 dB ensures that errors from finite squeezing acting on encoded qubits are below the fault-tolerance threshold of known qubit-based error-correcting codes. By concatenating with one of these codes and using ancilla-based error correction, fault-tolerant measurement-based quantum computation of theoretically indefinite length is possible with finitely squeezed cluster states.

  9. Prediction of parturition in bitches utilizing continuous vaginal temperature measurement.

    PubMed

    Geiser, B; Burfeind, O; Heuwieser, W; Arlt, S

    2014-02-01

    The objective of this study was to determine sensitivity and specificity of a body temperature decline in bitches to predict parturition. Temperature loggers were placed into the vaginal cavity of 16 pregnant bitches on day 56-61 after estimated ovulation or first mating. This measurement technique has been validated previously and enabled continuous sampling of body temperature. The temperature loggers were expelled from the vagina before delivery of the first pup. The computed values for specificity (77-92%) were higher than sensitivity (53-69%), indicating a more precise prognosis of parturition not occurring. In conclusion, our findings may assist interpreting vaginal temperature measurements in order to predict parturition in bitches. © 2013 Blackwell Verlag GmbH.

  10. Continuous measurement of two spatially separated superconducting qubits: quantum trajectories and statistics

    NASA Astrophysics Data System (ADS)

    Roch, Nicolas

    2015-03-01

    Measurement can be harnessed to probabilistically generate entanglement in the absence of local interactions, for example between spatially separated quantum objects. Continuous weak measurement allows us to observe the dynamics associated with this process. In particular, we perform joint dispersive readout of two superconducting transmon qubits separated by one meter of coaxial cable. We track the evolution of a joint quantum state under the influence of measurement, both as an ensemble and as a set of individual quantum trajectories. Analyzing the statistics of such quantum trajectories can shed new light on the underlying entangling mechanism.

  11. Angiotensin-converting enzyme DD genotype in patients with primary pulmonary hypertension: increased frequency and association with preserved haemodynamics.

    PubMed

    Abraham, William T; Raynolds, Mary V; Badesch, David B; Wynne, Kristine M; Groves, Bertron M; Roden, Robert L; Robertson, Alastair D; Lowes, Brian D; Zisman, Lawrence S; Voelkel, Norbert F; Bristow, Michael R; Perryman, M Benjamin

    2003-03-01

    HYPOTHESIS/INTRODUCTION: A polymorphic marker within the angiotensin- converting enzyme (ACE) gene has been associated with circulating and tissue ACE activity and with a variety of forms of cardiovascular disease. Since angiotensin II (Ang II) causes pulmonary vasoconstriction and vascular and myocardial remodelling, we postulated a role for the renin-angiotensin system and the ACE DD genotype in the pathophysiology of primary pulmonary hypertension (PPH) and in the right ventricular response to pressure overload in these patients. The incidence of the ACE DD genotype was evaluated in 60 patients with severe PPH compared with two normal control populations, a group of healthy population-based controls (n=158) and subjects found suitable for cardiac organ donation (n=79). Genomic DNA extracted from peripheral leukocytes was amplified using the polymerase chain reaction to detect polymorphic markers. Haemodynamics were determined by right heart catheterisation in a subset of the PPH patients. The frequency of the ACE DD genotype was 45% in the patients with PPH, compared with 24% in the organ donors, and 28% in population-based healthy controls (p=0.01 for chi-square test). Of the 32 PPH patients with baseline haemodynamics, 12 exhibited the ACE DD genotype and 20 were non-DD. While the mean pulmonary artery pressure and the duration of symptoms attributable to pulmonary hypertension was not different between the DD and non-DD groups, cardiac output was significantly lower (3.29+0.27 vs. 5.07+0.37 L/minute, p=0.002) and the mean right atrial pressure tended to be higher (8.85+1.29 vs. 4.92+1.27 mmHg, p=0.08) in the non-DD group. The reduction in cardiac output seen in the non-DD group was not due to a difference in heart rate, but to a significant reduction in stroke volume, consistent with a decreased contractile state. In addition, non-DD patients exhibited a significantly worse functional capacity (NYHA Class 3.14+0.12 vs. 2.40+0.28, p=0.02). 1) The ACE DD

  12. Implementation of projective measurements with linear optics and continuous photon counting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takeoka, Masahiro; Sasaki, Masahide; Loock, Peter van

    2005-02-01

    We investigate the possibility of implementing a given projection measurement using linear optics and arbitrarily fast feedforward based on the continuous detection of photons. In particular, we systematically derive the so-called Dolinar scheme that achieves the minimum-error discrimination of binary coherent states. Moreover, we show that the Dolinar-type approach can also be applied to projection measurements in the regime of photonic-qubit signals. Our results demonstrate that for implementing a projection measurement with linear optics, in principle, unit success probability may be approached even without the use of expensive entangled auxiliary states, as they are needed in all known (near-)deterministic linear-opticsmore » proposals.« less

  13. Continuous-Variable Measurement-Device-Independent Multipartite Quantum Communication Using Coherent States

    NASA Astrophysics Data System (ADS)

    Zhou, Jian; Guo, Ying

    2017-02-01

    A continuous-variable measurement-device-independent (CV-MDI) multipartite quantum communication protocol is designed to realize multipartite communication based on the GHZ state analysis using Gaussian coherent states. It can remove detector side attack as the multi-mode measurement is blindly done in a suitable Black Box. The entanglement-based CV-MDI multipartite communication scheme and the equivalent prepare-and-measurement scheme are proposed to analyze the security and guide experiment, respectively. The general eavesdropping and coherent attack are considered for the security analysis. Subsequently, all the attacks are ascribed to coherent attack against imperfect links. The asymptotic key rate of the asymmetric configuration is also derived with the numeric simulations illustrating the performance of the proposed protocol.

  14. Step-height measurement with a low coherence interferometer using continuous wavelet transform

    NASA Astrophysics Data System (ADS)

    Jian, Zhang; Suzuki, Takamasa; Choi, Samuel; Sasaki, Osami

    2013-12-01

    With the development of electronic technology in recent years, electronic components become increasingly miniaturized. At the same time a more accurate measurement method becomes indispensable. In the current measurement of nano-level, the Michelson interferometer with the laser diode is widely used, the method can measure the object accurately without touching the object. However it can't measure the step height that is larger than the half-wavelength. In this study, we improve the conventional Michelson interferometer by using a super luminescent diode and continuous wavelet transform, which can detect the time that maximizes the amplitude of the interference signal. We can accurately measure the surface-position of the object with this time. The method used in this experiment measured the step height of 20 microns.

  15. Continuous wave cavity ring-down spectroscopy for velocity distribution measurements in plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCarren, D.; Lockheed Martin, Palmdale, California 93599; Scime, E., E-mail: earl.scime@mail.wvu.edu

    2015-10-15

    We report the development of a continuous wave cavity ring-down spectroscopic (CW-CRDS) diagnostic for real-time, in situ measurement of velocity distribution functions of ions and neutral atoms in plasma. This apparatus is less complex than conventional CW-CRDS systems. We provide a detailed description of the CW-CRDS apparatus as well as measurements of argon ions and neutrals in a high-density (10{sup 9} cm{sup −3} < plasma density <10{sup 13} cm{sup −3}) plasma. The CW-CRDS measurements are validated through comparison with laser induced fluorescence measurements of the same absorbing states of the ions and neutrals.

  16. Single-shot quantum state estimation via a continuous measurement in the strong backaction regime

    NASA Astrophysics Data System (ADS)

    Cook, Robert L.; Riofrío, Carlos A.; Deutsch, Ivan H.

    2014-09-01

    We study quantum tomography based on a stochastic continuous-time measurement record obtained from a probe field collectively interacting with an ensemble of identically prepared systems. In comparison to previous studies, we consider here the case in which the measurement-induced backaction has a non-negligible effect on the dynamical evolution of the ensemble. We formulate a maximum likelihood estimate for the initial quantum state given only a single instance of the continuous diffusive measurement record. We apply our estimator to the simplest problem: state tomography of a single pure qubit, which, during the course of the measurement, is also subjected to dynamical control. We identify a regime where the many-body system is well approximated at all times by a separable pure spin coherent state, whose Bloch vector undergoes a conditional stochastic evolution. We simulate the results of our estimator and show that we can achieve close to the upper bound of fidelity set by the optimal generalized measurement. This estimate is compared to, and significantly outperforms, an equivalent estimator that ignores measurement backaction.

  17. Bayesian adjustment for measurement error in continuous exposures in an individually matched case-control study.

    PubMed

    Espino-Hernandez, Gabriela; Gustafson, Paul; Burstyn, Igor

    2011-05-14

    In epidemiological studies explanatory variables are frequently subject to measurement error. The aim of this paper is to develop a Bayesian method to correct for measurement error in multiple continuous exposures in individually matched case-control studies. This is a topic that has not been widely investigated. The new method is illustrated using data from an individually matched case-control study of the association between thyroid hormone levels during pregnancy and exposure to perfluorinated acids. The objective of the motivating study was to examine the risk of maternal hypothyroxinemia due to exposure to three perfluorinated acids measured on a continuous scale. Results from the proposed method are compared with those obtained from a naive analysis. Using a Bayesian approach, the developed method considers a classical measurement error model for the exposures, as well as the conditional logistic regression likelihood as the disease model, together with a random-effect exposure model. Proper and diffuse prior distributions are assigned, and results from a quality control experiment are used to estimate the perfluorinated acids' measurement error variability. As a result, posterior distributions and 95% credible intervals of the odds ratios are computed. A sensitivity analysis of method's performance in this particular application with different measurement error variability was performed. The proposed Bayesian method to correct for measurement error is feasible and can be implemented using statistical software. For the study on perfluorinated acids, a comparison of the inferences which are corrected for measurement error to those which ignore it indicates that little adjustment is manifested for the level of measurement error actually exhibited in the exposures. Nevertheless, a sensitivity analysis shows that more substantial adjustments arise if larger measurement errors are assumed. In individually matched case-control studies, the use of conditional

  18. Continuous-variable measurement-device-independent quantum key distribution with virtual photon subtraction

    NASA Astrophysics Data System (ADS)

    Zhao, Yijia; Zhang, Yichen; Xu, Bingjie; Yu, Song; Guo, Hong

    2018-04-01

    The method of improving the performance of continuous-variable quantum key distribution protocols by postselection has been recently proposed and verified. In continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocols, the measurement results are obtained from untrusted third party Charlie. There is still not an effective method of improving CV-MDI QKD by the postselection with untrusted measurement. We propose a method to improve the performance of coherent-state CV-MDI QKD protocol by virtual photon subtraction via non-Gaussian postselection. The non-Gaussian postselection of transmitted data is equivalent to an ideal photon subtraction on the two-mode squeezed vacuum state, which is favorable to enhance the performance of CV-MDI QKD. In CV-MDI QKD protocol with non-Gaussian postselection, two users select their own data independently. We demonstrate that the optimal performance of the renovated CV-MDI QKD protocol is obtained with the transmitted data only selected by Alice. By setting appropriate parameters of the virtual photon subtraction, the secret key rate and tolerable excess noise are both improved at long transmission distance. The method provides an effective optimization scheme for the application of CV-MDI QKD protocols.

  19. Use of a recording fluorometer for continuous measurement of phytoplankton concentration

    NASA Astrophysics Data System (ADS)

    Mills, David K.; Tett, Paul B.

    1990-08-01

    By linking a battery operated logger unit and power supply with a submersible fluorometer we have been able to make continuous untended measurements ofphytoplankton chlorophyll fluorescence, and hence estimate algal biomass for periods of up to 35 days at moorings. Calibration aixi data processing procedures are described, and some examples of the results of deployments in waters around the United Kingdom are presented.

  20. Simultaneous continuous measurement of non-commuting observables and correlation in qubit trajectories

    NASA Astrophysics Data System (ADS)

    Chantasri, Areeya; Jordan, Andrew

    We consider the continuous quantum measurement of two or more non-commuting observables of a single qubit. Examples are presented for the measurement of two observables which can be mapped to two measurement axes on the Bloch sphere; a special case being the measurement along the X and Z bases. The qubit dynamics is described by the stochastic master equations which include the effect of decoherence and measurement inefficiencies. We investigate the qubit trajectories, their most likely paths, and their correlation functions using the stochastic path integral formalism. The correlation functions in qubit trajectories can be derived exactly for a special case and perturbatively for general cases. The theoretical predictions are compared with numerical simulations, as well as with trajectory data from the transmon superconducting qubit experiments.

  1. Stages of Change – Continuous Measure (URICA-E2): psychometrics of a Norwegian version

    PubMed Central

    Lerdal, Anners; Moe, Britt; Digre, Elin; Harding, Thomas; Kristensen, Frode; Grov, Ellen K; Bakken, Linda N; Eklund, Marthe L; Ruud, Ireen; Rossi, Joseph S

    2009-01-01

    Title Stages of Change – Continuous Measure (URICA-E2): psychometrics of a Norwegian version. Aim This paper is a report of research to translate the English version of the Stages of Change continuous measure questionnaire (URICA-E2) into Norwegian and to test the validity of the questionnaire and its usefulness in predicting behavioural change. Background While the psychometric properties of the Stages of Change categorical measure have been tested extensively, evaluation of the psychometric properties of the continuous questionnaire has not been described elsewhere in the literature. Method Cross-sectional data were collected with a convenience sample of 198 undergraduate nursing students in 2005 and 2006. The English version of URICA-E2 was translated into Norwegian according to standardized procedures. Findings Principal components analysis clearly confirmed five of the dimensions of readiness to change (Precontemplation Non-Believers, Precontemplation Believers, Contemplation, Preparation and Maintenance), while the sixth dimension, Action, showed the lowest Eigenvalue (0·93). Findings from the cluster analysis indicate distinct profiles among the respondents in terms of readiness to change their exercise behaviour. Conclusion The URICA-E2 was for the most part replicated from Reed’s original work. The result of the cluster analysis of the items associated with the factor ‘Action’ suggests that these do not adequately measure the factor. PMID:19032513

  2. Impact of treatment delay on mortality in ST-segment elevation myocardial infarction (STEMI) patients presenting with and without haemodynamic instability: results from the German prospective, multicentre FITT-STEMI trial.

    PubMed

    Scholz, Karl Heinrich; Maier, Sebastian K G; Maier, Lars S; Lengenfelder, Björn; Jacobshagen, Claudius; Jung, Jens; Fleischmann, Claus; Werner, Gerald S; Olbrich, Hans G; Ott, Rainer; Mudra, Harald; Seidl, Karlheinz; Schulze, P Christian; Weiss, Christian; Haimerl, Josef; Friede, Tim; Meyer, Thomas

    2018-04-01

    The aim of this study was to investigate the effect of contact-to-balloon time on mortality in ST-segment elevation myocardial infarction (STEMI) patients with and without haemodynamic instability. Using data from the prospective, multicentre Feedback Intervention and Treatment Times in ST-Elevation Myocardial Infarction (FITT-STEMI) trial, we assessed the prognostic relevance of first medical contact-to-balloon time in n = 12 675 STEMI patients who used emergency medical service transportation and were treated with primary percutaneous coronary intervention (PCI). Patients were stratified by cardiogenic shock (CS) and out-of-hospital cardiac arrest (OHCA). For patients treated within 60 to 180 min from the first medical contact, we found a nearly linear relationship between contact-to-balloon times and mortality in all four STEMI groups. In CS patients with no OHCA, every 10-min treatment delay resulted in 3.31 additional deaths in 100 PCI-treated patients. This treatment delay-related increase in mortality was significantly higher as compared to the two groups of OHCA patients with shock (2.09) and without shock (1.34), as well as to haemodynamically stable patients (0.34, P < 0.0001). In patients with CS, the time elapsing from the first medical contact to primary PCI is a strong predictor of an adverse outcome. This patient group benefitted most from immediate PCI treatment, hence special efforts to shorten contact-to-balloon time should be applied in particular to these high-risk STEMI patients. NCT00794001.

  3. SAMPLING DURATION DEPENDENCE OF SEMI-CONTINUOUS ORGANIC CARBON MEASUREMENTS ON STEADY STATE SECONDARY ORGANIC AEROSOLS

    EPA Science Inventory

    Semi-continuous organic carbon concentrations were measured through several experiments of statically generated secondary organic aerosol formed by hydrocarbon + NOx irradiations. Repeated, randomized measurements of these steady state aerosols reveal decreases in the observed c...

  4. Continuous measurements of mandibular cortical width on dental panoramic radiographs for computer-aided diagnosis of osteoporosis

    NASA Astrophysics Data System (ADS)

    Kavitha, M. S.; Asano, Akira; Taguchi, Akira

    2011-03-01

    The aim of this study is to develop a computer-aided osteoporosis diagnosis system that automatically determines the inferior cortical width of the mandible continuously on dental panoramic radiographs to realize statistically more robust measurements than the conventional one-point measurements. The cortical width was continuously measured on dental panoramic radiographs by enhancing the original image, determining cortical boundaries, and finally evaluating the distance between boundaries continuously throughout the region of interest. The diagnostic performance using the average width calculated from the continuous measurement was compared with BMD at lumbar spine and femoral neck in 100 postmenopausal women of whom 50 to the development of the tool and 50 to its validation with no history of osteoporosis was evaluated. We experimentally showed the superiority of our method with improved sensitivity and specificity of identifying the development subjects were 90.0% and 75.0% in women with low spinal BMD and 81.8% and 69.2% in those with low femoral BMD, respectively. The corresponding values in the validation subjects were 93.3% and 82.9% at the lumbar spine and 92.3% and 75.7% at the femoral neck, respectively in terms of efficacy for diagnosing osteoporosis. We also assessed the diagnosis and classification of women with osteoporosis using support vector machine employing the average and variance of the continuous measurements gave excellent discrimination ability. It yields sensitivity and specificity of 90.9% and 83.8%, respectively with lumbar spine and 90.0% and 69.1%, respectively with femoral neck BMD. Performance comparison and simplicity of this method indicate that our computeraided system is readily applicable to clinical practice.

  5. Application of automated measurement stations for continuous water quality monitoring of the Dender river in Flanders, Belgium.

    PubMed

    Vandenberghe, V; Goethals, P L M; Van Griensven, A; Meirlaen, J; De Pauw, N; Vanrolleghem, P; Bauwens, W

    2005-09-01

    During the summer of 1999, two automated water quality measurement stations were installed along the Dender river in Belgium. The variables dissolved oxygen, temperature, conductivity, pH, rain-intensity, flow and solar radiation were measured continuously. In this paper these on-line measurement series are presented and interpreted using also additional measurements and ecological expert-knowledge. The purpose was to demonstrate the variability in time and space of the aquatic processes and the consequences of conducting and interpreting discrete measurements for river quality assessment and management. The large fluctuations of the data illustrated the importance of continuous measurements for the complete description and modelling of the biological processes in the river.

  6. Odds Ratio Product of Sleep EEG as a Continuous Measure of Sleep State

    PubMed Central

    Younes, Magdy; Ostrowski, Michele; Soiferman, Marc; Younes, Henry; Younes, Mark; Raneri, Jill; Hanly, Patrick

    2015-01-01

    Study Objectives: To develop and validate an algorithm that provides a continuous estimate of sleep depth from the electroencephalogram (EEG). Design: Retrospective analysis of polysomnograms. Setting: Research laboratory. Participants: 114 patients who underwent clinical polysomnography in sleep centers at the University of Manitoba (n = 58) and the University of Calgary (n = 56). Interventions: None. Measurements and Results: Power spectrum of EEG was determined in 3-second epochs and divided into delta, theta, alpha-sigma, and beta frequency bands. The range of powers in each band was divided into 10 aliquots. EEG patterns were assigned a 4-digit number that reflects the relative power in the 4 frequency ranges (10,000 possible patterns). Probability of each pattern occurring in 30-s epochs staged awake was determined, resulting in a continuous probability value from 0% to 100%. This was divided by 40 (% of epochs staged awake) producing the odds ratio product (ORP), with a range of 0–2.5. In validation testing, average ORP decreased progressively as EEG progressed from wakefulness (2.19 ± 0.29) to stage N3 (0.13 ± 0.05). ORP < 1.0 predicted sleep and ORP > 2.0 predicted wakefulness in > 95% of 30-s epochs. Epochs with intermediate ORP occurred in unstable sleep with a high arousal index (> 70/h) and were subject to much interrater scoring variability. There was an excellent correlation (r2 = 0.98) between ORP in current 30-s epochs and the likelihood of arousal or awakening occurring in the next 30-s epoch. Conclusions: Our results support the use of the odds ratio product (ORP) as a continuous measure of sleep depth. Citation: Younes M, Ostrowski M, Soiferman M, Younes H, Younes M, Raneri J, Hanly P. Odds ratio product of sleep EEG as a continuous measure of sleep state. SLEEP 2015;38(4):641–654. PMID:25348125

  7. Assessment of valve haemodynamics, reverse ventricular remodelling and myocardial fibrosis following transcatheter aortic valve implantation compared to surgical aortic valve replacement: a cardiovascular magnetic resonance study

    PubMed Central

    Fairbairn, Timothy A; Steadman, Christopher D; Mather, Adam N; Motwani, Manish; Blackman, Daniel J; Plein, Sven; McCann, Gerry P; Greenwood, John P

    2013-01-01

    Objective To compare the effects of transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) on aortic valve haemodynamics, ventricular reverse remodelling and myocardial fibrosis (MF) by cardiovascular magnetic resonance (CMR) imaging. Design A 1.5 T CMR scan was performed preoperatively and 6 months postoperatively. Setting University hospitals of Leeds and Leicester, UK. Patients 50 (25 TAVI, 25 SAVR; age 77±8 years) high-risk severe symptomatic aortic stenosis (AS) patients. Main outcome measures Valve haemodynamics, ventricular volumes, ejection fraction (EF), mass and MF. Results Patients were matched for gender and AS severity but not for age (80±6 vs 73±7 years, p=0.001) or EuroSCORE (22±14 vs 7±3, p<0.001). Aortic valve mean pressure gradient decreased to a greater degree post-TAVI compared to SAVR (21±8 mm Hg vs 35±13 mm Hg, p=0.017). Aortic regurgitation reduced by 8% in both groups, only reaching statistical significance for TAVI (p=0.003). TAVI and SAVR improved (p<0.05) left ventricular (LV) end-systolic volumes (46±18 ml/m2 vs 41±17 ml/m2; 44±22 ml/m2 vs32±6 ml/m2) and mass (83±20 g/m2 vs 65±15 g/m2; 74±11 g/m2 vs 59±8 g/m2). SAVR reduced end-diastolic volumes (92±19 ml/m2 vs 74±12 ml/m2, p<0.001) and TAVI increased EF (52±12% vs 56±10%, p=0.01). MF reduced post-TAVI (10.9±6% vs 8.5±5%, p=0.03) but not post-SAVR (4.2±2% vs 4.1±2%, p=0.98). Myocardial scar (p≤0.01) and baseline ventricular volumes (p<0.001) were the major predictors of reverse remodelling. Conclusions TAVI was comparable to SAVR at LV reverse remodelling and superior at reducing the valvular pressure gradient and MF. Future work should assess the prognostic importance of reverse remodelling and fibrosis post-TAVI to aid patient selection. PMID:23749779

  8. Qubit models of weak continuous measurements: markovian conditional and open-system dynamics

    NASA Astrophysics Data System (ADS)

    Gross, Jonathan A.; Caves, Carlton M.; Milburn, Gerard J.; Combes, Joshua

    2018-04-01

    In this paper we approach the theory of continuous measurements and the associated unconditional and conditional (stochastic) master equations from the perspective of quantum information and quantum computing. We do so by showing how the continuous-time evolution of these master equations arises from discretizing in time the interaction between a system and a probe field and by formulating quantum-circuit diagrams for the discretized evolution. We then reformulate this interaction by replacing the probe field with a bath of qubits, one for each discretized time segment, reproducing all of the standard quantum-optical master equations. This provides an economical formulation of the theory, highlighting its fundamental underlying assumptions.

  9. Optical fiber-based system for continuous measurement of in-bore projectile velocity.

    PubMed

    Wang, Guohua; Sun, Jinglin; Li, Qiang

    2014-08-01

    This paper reports the design of an optical fiber-based velocity measurement system and its application in measuring the in-bore projectile velocity. The measurement principle of the implemented system is based on Doppler effect and heterodyne detection technique. The analysis of the velocity measurement principle deduces the relationship between the projectile velocity and the instantaneous frequency (IF) of the optical fiber-based system output signal. To extract the IF of the fast-changing signal carrying the velocity information, an IF extraction algorithm based on the continuous wavelet transforms is detailed. Besides, the performance of the algorithm is analyzed by performing corresponding simulation. At last, an in-bore projectile velocity measurement experiment with a sniper rifle having a 720 m/s muzzle velocity is performed to verify the feasibility of the optical fiber-based velocity measurement system. Experiment results show that the measured muzzle velocity is 718.61 m/s, and the relative uncertainty of the measured muzzle velocity is approximately 0.021%.

  10. Optical fiber-based system for continuous measurement of in-bore projectile velocity

    NASA Astrophysics Data System (ADS)

    Wang, Guohua; Sun, Jinglin; Li, Qiang

    2014-08-01

    This paper reports the design of an optical fiber-based velocity measurement system and its application in measuring the in-bore projectile velocity. The measurement principle of the implemented system is based on Doppler effect and heterodyne detection technique. The analysis of the velocity measurement principle deduces the relationship between the projectile velocity and the instantaneous frequency (IF) of the optical fiber-based system output signal. To extract the IF of the fast-changing signal carrying the velocity information, an IF extraction algorithm based on the continuous wavelet transforms is detailed. Besides, the performance of the algorithm is analyzed by performing corresponding simulation. At last, an in-bore projectile velocity measurement experiment with a sniper rifle having a 720 m/s muzzle velocity is performed to verify the feasibility of the optical fiber-based velocity measurement system. Experiment results show that the measured muzzle velocity is 718.61 m/s, and the relative uncertainty of the measured muzzle velocity is approximately 0.021%.

  11. Comparison of Different Cuff Pressure Use with the Supreme Laryngeal Mask Airway on Haemodynamic Response, Seal Pressure and Postoperative Adverse Events: A Prospective Randomized Study.

    PubMed

    Ali, Achmet; Altun, Demet; Sivrikoz, Nukhet; Yornuk, Mesut; Turgut, Namigar; Akıncı, İbrahim Özkan

    2018-04-01

    The Supreme™ laryngeal mask airway (SLMA) is a supra glottic airway (SGA) device that is used as an alternative to endotracheal tubes. In the present study, we aimed to compare the use of the SLMA with normal cuff pressure and low cuff pressure, primarily for haemodynamic response. In the present study, 120 patients diagnosed with hypertension and scheduled for varicose vein or inguinal hernia operation were enrolled and 99 patients finished. Using randomization, patients were divided into two groups according to cuff pressure as a low-pressure group (Group L, 45 cm H 2 O) and a normal-pressure group (Group N, 60 cm H 2 O). Demographics, Mallampati score and the type and duration of surgery, heart rate (HR), mean arterial pressure (MAP), percentage of tidal volume leakage, Ppeak, Pmean, etCO 2 , seal pressure, fibreoptic scores and postoperative adverse effects of all patients were recorded. MAP and HR values immediately and 2 minutes after SLMA insertion were significantly lower in Group L (p<0.001). In Group L and Group N, the seal pressures were 24.1±3.1 cm H 2 O and 26.2±3.9 cm H 2 O, respectively (p=0.003). Also, blood staining and sore throat occurred less frequently in Group L (p<0.05). The fibreoptic average score, insertion features and ventilation parameters were similar between the groups (p>0.05). SLMA use with a cuff pressure of 45 cm H 2 O significantly decreases haemodynamic response and post-operative side effects compared with a normal cuff pressure. Therefore, except for some specific surgeries that require higher seal pressures, we recommend the use of the SLMA with cuff pressures as low as 45 cm H 2 O.

  12. Effects of ageing and Alzheimer disease on haemodynamic response function: a challenge for event-related fMRI.

    PubMed

    Asemani, Davud; Morsheddost, Hassan; Shalchy, Mahsa Alizadeh

    2017-06-01

    Functional magnetic resonance imaging (fMRI) can generate brain images that show neuronal activity due to sensory, cognitive or motor tasks. Haemodynamic response function (HRF) may be considered as a biomarker to discriminate the Alzheimer disease (AD) from healthy ageing. As blood-oxygenation-level-dependent fMRI signal is much weak and noisy, particularly for the elderly subjects, a robust method is necessary for HRF estimation to efficiently differentiate the AD. After applying minimum description length wavelet as an extra denoising step, deconvolution algorithm is here employed for HRF estimation, substituting the averaging method used in the previous works. The HRF amplitude peaks are compared for three groups HRF of young, non-demented and demented elderly groups for both vision and motor regions. Prior works often reported significant differences in the HRF peak amplitude between the young and the elderly. The authors' experimentations show that the HRF peaks are not significantly different comparing the young adults with the elderly (either demented or non-demented). It is here demonstrated that the contradictory findings of the previous studies on the HRF peaks for the elderly compared with the young are originated from the noise contribution in fMRI data.

  13. Exploring Quantum Dynamics of Continuous Measurement with a Superconducting Qubit

    NASA Astrophysics Data System (ADS)

    Jadbabaie, Arian; Forouzani, Neda; Tan, Dian; Murch, Kater

    Weak measurements obtain partial information about a quantum state with minimal backaction. This enables state tracking without immediate collapse to eigenstates, of interest to both experimental and theoretical physics. State tomography and continuous weak measurements may be used to reconstruct the evolution of a single system, known as a quantum trajectory. We examine experimental trajectories of a two-level system at varied measurement strengths with constant unitary drive. Our analysis is applied to a transmon qubit dispersively coupled to a 3D microwave cavity in the circuit QED architecture. The weakly coupled cavity acts as pointer system for QND measurements in the qubit's energy basis. Our results indicate a marked difference in state purity between two approaches for trajectory reconstruction: the Bayesian and Stochastic Master Equation (SME) formalisms. Further, we observe the transition from diffusive to jump-like trajectories, state purity evolution, and a novel, tilted form of the Quantum Zeno effect. This work provides new insight into quantum behavior and prompts further comparison of SME and Bayesian formalisms to understand the nature of quantum systems. Our results are applicable to a variety of fields, from stochastic thermodynamics to quantum control.

  14. STUDY ON A STEP-ADVANCED FILTER MONITOR FOR CONTINUOUS RADON PROGENY MEASUREMENT.

    PubMed

    Zhang, Lei; Yang, Jinmin; Guo, Qiuju

    2017-04-01

    Traditional fixed-filter radon progeny monitors are usually clogged with the loading of dust and cannot be used for radon progeny continuous measurement for long period. To solve this problem, a step-advanced filter (SAF) monitor for radon progeny measurement was developed. This monitor automatically roll and stop the filter at each interview. Radon progeny is collected on a 'fresh' filter at a flowrate of 3 L/min. At the same time, alpha and beta particles emitted from filter are recorded by a PIPS detector. A newly developed alpha-beta spectrum method was used for radon progeny concentration calculation. The 218Po, 214Pb and 214Bi concentrations as well as equilibrium equivalent concentration (EEC) could be worked out at the same time. The lower level limit detection of this monitor is 0.48 Bq m-3 (EEC) for 1h interval. Comparison experiments were carried out in the radon chamber at the National Institute of Metrology of China. The measurement results of this SAF monitor are consistent with EQF3220 (SARAD GmbH, Germany), and the uncertainty is smaller. Due to its high sensitivity, the periodical variation of radon progeny concentration can be easily observed by this monitor. The SAF moniter is suitable for continuous measurement in both indoor and outdoor environments. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Continuous measurement of breast tumor hormone receptor expression: a comparison of two computational pathology platforms

    PubMed Central

    Ahern, Thomas P.; Beck, Andrew H.; Rosner, Bernard A.; Glass, Ben; Frieling, Gretchen; Collins, Laura C.; Tamimi, Rulla M.

    2017-01-01

    Background Computational pathology platforms incorporate digital microscopy with sophisticated image analysis to permit rapid, continuous measurement of protein expression. We compared two computational pathology platforms on their measurement of breast tumor estrogen receptor (ER) and progesterone receptor (PR) expression. Methods Breast tumor microarrays from the Nurses’ Health Study were stained for ER (n=592) and PR (n=187). One expert pathologist scored cases as positive if ≥1% of tumor nuclei exhibited stain. ER and PR were then measured with the Definiens Tissue Studio (automated) and Aperio Digital Pathology (user-supervised) platforms. Platform-specific measurements were compared using boxplots, scatter plots, and correlation statistics. Classification of ER and PR positivity by platform-specific measurements was evaluated with areas under receiver operating characteristic curves (AUC) from univariable logistic regression models, using expert pathologist classification as the standard. Results Both platforms showed considerable overlap in continuous measurements of ER and PR between positive and negative groups classified by expert pathologist. Platform-specific measurements were strongly and positively correlated with one another (rho≥0.77). The user-supervised Aperio workflow performed slightly better than the automated Definiens workflow at classifying ER positivity (AUCAperio=0.97; AUCDefiniens=0.90; difference=0.07, 95% CI: 0.05, 0.09) and PR positivity (AUCAperio=0.94; AUCDefiniens=0.87; difference=0.07, 95% CI: 0.03, 0.12). Conclusion Paired hormone receptor expression measurements from two different computational pathology platforms agreed well with one another. The user-supervised workflow yielded better classification accuracy than the automated workflow. Appropriately validated computational pathology algorithms enrich molecular epidemiology studies with continuous protein expression data and may accelerate tumor biomarker discovery. PMID

  16. Acute renal haemodynamic and renin-angiotensin system responses to graded renal artery stenosis in the dog.

    PubMed Central

    Anderson, W P; Johnston, C I; Korner, P I

    1979-01-01

    1. The acute renal haemodynamic and renin-angiotensin system responses to graded renal artery stenosis were studied in chronically instrumented, unanaesthetized dogs. 2. Stenosis was induced over 30 sec by inflation of a cuff around the renal artery to lower distal pressure to 60, 40 or 20 mmHg, with stenosis maintained for 1 hr. This resulted in an immediate fall in renal vascular resistance, but over the next 5--30 min both resistance and renal artery pressure were restored back towards prestenosis values. Only transient increases in systemic arterial blood pressure and plasma renin and angiotensin levels were seen with the two milder stenoses. Despite restoration of renal artery pressure, renal blood flow remained reduced at all grades of stenosis. 3. Pre-treatment with angiotensin I converting enzyme inhibitor or sarosine1, isoleucone8 angiotensin II greatly attenuated or abolished the restoration of renal artery pressure and renal vascular resistance after stenosis, and plasma renin and angiotensin II levels remained high. Renal dilatation was indefinitely maintained, but the normal restoration of resistance and pressure could be simulated by infusing angiotensin II into the renal artery. 4. The effective resistance to blood flow by the stenosis did not remain constant but varied with changes in the renal vascular resistance. PMID:219182

  17. Experimental Measurements of Sonic Boom Signatures Using a Continuous Data Acquisition Technique

    NASA Technical Reports Server (NTRS)

    Wilcox, Floyd J.; Elmiligui, Alaa A.

    2013-01-01

    A wind tunnel investigation was conducted in the Langley Unitary Plan Wind Tunnel to determine the effectiveness of a technique to measure aircraft sonic boom signatures using a single conical survey probe while continuously moving the model past the probe. Sonic boom signatures were obtained using both move-pause and continuous data acquisition methods for comparison. The test was conducted using a generic business jet model at a constant angle of attack and a single model-to-survey-probe separation distance. The sonic boom signatures were obtained at a Mach number of 2.0 and a unit Reynolds number of 2 million per foot. The test results showed that it is possible to obtain sonic boom signatures while continuously moving the model and that the time required to acquire the signature is at least 10 times faster than the move-pause method. Data plots are presented with a discussion of the results. No tabulated data or flow visualization photographs are included.

  18. Continuous measurements of N2O emissions from arable fields

    NASA Astrophysics Data System (ADS)

    Wallman, Magdalena; Lammirato, Carlo; Rütting, Tobias; Delin, Sofia; Weslien, Per; Klemedtsson, Leif

    2017-04-01

    Agriculture represents 59 % of the anthropogenic nitrous oxide (N2O) emissions, according to the IPCC (Ciais et al. 2013). N2O emissions are typically irregular and vary widely in time and space, which makes it difficult to get a good representation of the emissions (Henault et al. 2012), particularly if measurements have low frequency and/or cover only a short time period. Manual measurements are, for practical reasons, often short-term and low-frequent, or restricted to periods where emissions are expected to be high, e.g. after fertilizing. However, the nature of N2O emissions, being largely unpredictable, calls for continuous or near-continuous measurements over long time periods. So far, rather few long-term, high resolution measurements of N2O emissions from arable fields are reported; among them are Flessa et al. (2002) and Senapati et al. (2016). In this study, we have a two-year data set (2015-2017) with hourly measurements from ten automatic chambers, covering unfertilized controls as well as different nitrogen fertilizer treatments. Grain was produced on the field, and effects of tillage, harvest and other cropping measures were covered. What we can see from the experiment is that (a) the unfertilized control plots seem to follow the same emission pattern as the fertilized plots, at a level similar to the standard mineral fertilized plots (120 kg N ha-1 yr-1) and (b) freeze/thaw emissions are comparable in size to emissions after fertilizing. These two findings imply that the importance of fertilizing to the overall N2O emissions from arable soils may be smaller than previously expected. References: Ciais, P., C. Sabine, G. Bala, L. Bopp, V. Brovkin, J. Canadell et al. 2013: Carbon and Other Biogeochemical Cycles. In: Climate Change 2013: The Physical Science Basis. Contribution of Working Group I to the Fifth Assessment Report of the Intergovernmental Panel on Climate Change [Stocker, T.F., D. Qin, G.-K. Plattner, M. Tignor, S.K. Allen, J. Boschung et

  19. Violation of continuous-variable Einstein-Podolsky-Rosen steering with discrete measurements.

    PubMed

    Schneeloch, James; Dixon, P Ben; Howland, Gregory A; Broadbent, Curtis J; Howell, John C

    2013-03-29

    In this Letter, we derive an entropic Einstein-Podolsky-Rosen (EPR) steering inequality for continuous-variable systems using only experimentally measured discrete probability distributions and details of the measurement apparatus. We use this inequality to witness EPR steering between the positions and momenta of photon pairs generated in spontaneous parametric down-conversion. We examine the asymmetry between parties in this inequality, and show that this asymmetry can be used to reduce the technical requirements of experimental setups intended to demonstrate the EPR paradox. Furthermore, we develop a more stringent steering inequality that is symmetric between parties, and use it to show that the down-converted photon pairs also exhibit symmetric EPR steering.

  20. Violation of Continuous-Variable Einstein-Podolsky-Rosen Steering with Discrete Measurements

    NASA Astrophysics Data System (ADS)

    Schneeloch, James; Dixon, P. Ben; Howland, Gregory A.; Broadbent, Curtis J.; Howell, John C.

    2013-03-01

    In this Letter, we derive an entropic Einstein-Podolsky-Rosen (EPR) steering inequality for continuous-variable systems using only experimentally measured discrete probability distributions and details of the measurement apparatus. We use this inequality to witness EPR steering between the positions and momenta of photon pairs generated in spontaneous parametric down-conversion. We examine the asymmetry between parties in this inequality, and show that this asymmetry can be used to reduce the technical requirements of experimental setups intended to demonstrate the EPR paradox. Furthermore, we develop a more stringent steering inequality that is symmetric between parties, and use it to show that the down-converted photon pairs also exhibit symmetric EPR steering.

  1. Pulse high-volume haemofiltration for treatment of severe sepsis: effects on hemodynamics and survival

    PubMed Central

    Ratanarat, Ranistha; Brendolan, Alessandra; Piccinni, Pasquale; Dan, Maurizio; Salvatori, Gabriella; Ricci, Zaccaria; Ronco, Claudio

    2005-01-01

    Introduction Severe sepsis is the leading cause of mortality in critically ill patients. Abnormal concentrations of inflammatory mediators appear to be involved in the pathogenesis of sepsis. Based on the humoral theory of sepsis, a potential therapeutic approach involves high-volume haemofiltration (HVHF), which has exhibited beneficial effects in severe sepsis, improving haemodynamics and unselectively removing proinflammatory and anti-inflammatory mediators. However, concerns have been expressed about the feasibility and costs of continuous HVHF. Here we evaluate a new modality, namely pulse HVHF (PHVHF; 24-hour schedule: HVHF 85 ml/kg per hour for 6–8 hours followed by continuous venovenous haemofiltration 35 ml/kg per hour for 16–18 hours). Method Fifteen critically ill patients (seven male; mean Acute Physiology and Chronic Health Evaluation [APACHE] II score 31.2, mean Simplified Acute Physiology Score [SAPS] II 62, and mean Sequential Organ Failure Assessment 14.2) with severe sepsis underwent daily PHVHF. We measured changes in haemodynamic variables and evaluated the dose of noradrenaline required to maintain mean arterial pressure above 70 mmHg during and after pulse therapy at 6 and 12 hours. PHVHF was performed with 250 ml/min blood flow rate. The bicarbonate-based replacement fluid was used at a 1:1 ratio in simultaneous pre-dilution and post-dilution. Results No treatment was prematurely discontinued. Haemodynamics were improved by PHVHF, allowing a significant reduction in noradrenaline dose during and at the end of the PHVHF session; this reduction was maintained at 6 and 12 hours after pulse treatment (P = 0.001). There was also an improvement in systolic blood pressure (P = 0.04). There were no changes in temperature, cardiac index, oxygenation, arterial pH or urine output during the period of observation. The mean daily Kt/V was 1.92. Predicted mortality rates were 72% (based on APACHE II score) and 68% (based on SAPS II score), and the

  2. [Current status of noninvasive hemodynamics in hypertension].

    PubMed

    Waisman, G

    Hypertension is a haemodynamic disorder resulting from a persistent mismatch between cardiac output and peripheral resistance. Hypertension undergoes haemodynamic progression during its natural history. Impedance cardiography is a method of evaluating the cardiovascular system that obtains haemodynamic information from beat to beat through the analysis of variations in the impedance of the thorax on the passage of an electric current. Impedance cardiography unmasks the haemodynamic deterioration underlying the increase in blood pressure as age and systolic blood pressure increases. This method may help to improve blood pressure control through individualized treatment with reduction of peripheral resistance, maintenance of cardiac output or its increase, improvement of arterial compliance and preservation of organ-tissue perfusion. It is useful in the management of patients with resistant hypertension, since a greater percentage of patients controlled with changes in the treatment in relation to the haemodynamic measurements are obtained. Impedance cardiography is important and has prognostic utility in relation to a haemodynamic deterioration pattern and increased cardiovascular events. Copyright © 2017 SEH-LELHA. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Continuous measurement of breast tumour hormone receptor expression: a comparison of two computational pathology platforms.

    PubMed

    Ahern, Thomas P; Beck, Andrew H; Rosner, Bernard A; Glass, Ben; Frieling, Gretchen; Collins, Laura C; Tamimi, Rulla M

    2017-05-01

    Computational pathology platforms incorporate digital microscopy with sophisticated image analysis to permit rapid, continuous measurement of protein expression. We compared two computational pathology platforms on their measurement of breast tumour oestrogen receptor (ER) and progesterone receptor (PR) expression. Breast tumour microarrays from the Nurses' Health Study were stained for ER (n=592) and PR (n=187). One expert pathologist scored cases as positive if ≥1% of tumour nuclei exhibited stain. ER and PR were then measured with the Definiens Tissue Studio (automated) and Aperio Digital Pathology (user-supervised) platforms. Platform-specific measurements were compared using boxplots, scatter plots and correlation statistics. Classification of ER and PR positivity by platform-specific measurements was evaluated with areas under receiver operating characteristic curves (AUC) from univariable logistic regression models, using expert pathologist classification as the standard. Both platforms showed considerable overlap in continuous measurements of ER and PR between positive and negative groups classified by expert pathologist. Platform-specific measurements were strongly and positively correlated with one another (r≥0.77). The user-supervised Aperio workflow performed slightly better than the automated Definiens workflow at classifying ER positivity (AUC Aperio =0.97; AUC Definiens =0.90; difference=0.07, 95% CI 0.05 to 0.09) and PR positivity (AUC Aperio =0.94; AUC Definiens =0.87; difference=0.07, 95% CI 0.03 to 0.12). Paired hormone receptor expression measurements from two different computational pathology platforms agreed well with one another. The user-supervised workflow yielded better classification accuracy than the automated workflow. Appropriately validated computational pathology algorithms enrich molecular epidemiology studies with continuous protein expression data and may accelerate tumour biomarker discovery. Published by the BMJ Publishing

  4. Bayesian functional integral method for inferring continuous data from discrete measurements.

    PubMed

    Heuett, William J; Miller, Bernard V; Racette, Susan B; Holloszy, John O; Chow, Carson C; Periwal, Vipul

    2012-02-08

    Inference of the insulin secretion rate (ISR) from C-peptide measurements as a quantification of pancreatic β-cell function is clinically important in diseases related to reduced insulin sensitivity and insulin action. ISR derived from C-peptide concentration is an example of nonparametric Bayesian model selection where a proposed ISR time-course is considered to be a "model". An inferred value of inaccessible continuous variables from discrete observable data is often problematic in biology and medicine, because it is a priori unclear how robust the inference is to the deletion of data points, and a closely related question, how much smoothness or continuity the data actually support. Predictions weighted by the posterior distribution can be cast as functional integrals as used in statistical field theory. Functional integrals are generally difficult to evaluate, especially for nonanalytic constraints such as positivity of the estimated parameters. We propose a computationally tractable method that uses the exact solution of an associated likelihood function as a prior probability distribution for a Markov-chain Monte Carlo evaluation of the posterior for the full model. As a concrete application of our method, we calculate the ISR from actual clinical C-peptide measurements in human subjects with varying degrees of insulin sensitivity. Our method demonstrates the feasibility of functional integral Bayesian model selection as a practical method for such data-driven inference, allowing the data to determine the smoothing timescale and the width of the prior probability distribution on the space of models. In particular, our model comparison method determines the discrete time-step for interpolation of the unobservable continuous variable that is supported by the data. Attempts to go to finer discrete time-steps lead to less likely models. Copyright © 2012 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  5. Non-invasive optical monitoring of the newborn piglet brain using continuous-wave and frequency-domain spectroscopy

    NASA Astrophysics Data System (ADS)

    Fantini, Sergio; Hueber, Dennis; Franceschini, Maria Angela; Gratton, Enrico; Rosenfeld, Warren; Stubblefield, Phillip G.; Maulik, Dev; Stankovic, Miljan R.

    1999-06-01

    We have used continuous-wave (CW) and frequency-domain spectroscopy to investigate the optical properties of the newborn piglet brain in vivo and non-invasively. Three anaesthetized, intubated, ventilated and instrumented newborn piglets were placed into a stereotaxic instrument for optimal experimental stability, reproducible probe-to-scalp optical contact and 3D adjustment of the optical probe. By measuring the absolute values of the brain absorption and reduced scattering coefficients at two wavelengths (758 and 830 nm), frequency-domain spectroscopy provided absolute readings (in contrast to the relative readings of CW spectroscopy) of cerebral haemoglobin concentration and saturation during experimentally induced perturbations in cerebral haemodynamics and oxygenation. Such perturbations included a modulation of the inspired oxygen concentration, transient brain asphyxia, carotid artery occlusion and terminal brain asphyxia. The baseline cerebral haemoglobin saturation and concentration, measured with frequency-domain spectroscopy, were about 60% and 42 µM respectively. The cerebral saturation values ranged from a minimum of 17% (during transient brain asphyxia) to a maximum of 80% (during recovery from transient brain asphyxia). To analyse the CW optical data, we have (a) derived a mathematical relationship between the cerebral optical properties and the differential pathlength factor and (b) introduced a method based on the spatial dependence of the detected intensity (dc slope method). The analysis of the cerebral optical signals associated with the arterial pulse and with respiration demonstrates that motion artefacts can significantly affect the intensity recorded from a single optode pair. Motion artefacts can be strongly reduced by combining data from multiple optodes to provide relative readings in the dc slope method. We also report significant biphasic changes (initial decrease and successive increase) in the reduced scattering coefficient measured

  6. Application of Allan Deviation to Assessing Uncertainties of Continuous-measurement Instruments, and Optimizing Calibration Schemes

    NASA Astrophysics Data System (ADS)

    Jacobson, Gloria; Rella, Chris; Farinas, Alejandro

    2014-05-01

    Technological advancement of instrumentation in atmospheric and other geoscience disciplines over the past decade has lead to a shift from discrete sample analysis to continuous, in-situ monitoring. Standard error analysis used for discrete measurements is not sufficient to assess and compare the error contribution of noise and drift from continuous-measurement instruments, and a different statistical analysis approach should be applied. The Allan standard deviation analysis technique developed for atomic clock stability assessment by David W. Allan [1] can be effectively and gainfully applied to continuous measurement instruments. As an example, P. Werle et al has applied these techniques to look at signal averaging for atmospheric monitoring by Tunable Diode-Laser Absorption Spectroscopy (TDLAS) [2]. This presentation will build on, and translate prior foundational publications to provide contextual definitions and guidelines for the practical application of this analysis technique to continuous scientific measurements. The specific example of a Picarro G2401 Cavity Ringdown Spectroscopy (CRDS) analyzer used for continuous, atmospheric monitoring of CO2, CH4 and CO will be used to define the basics features the Allan deviation, assess factors affecting the analysis, and explore the time-series to Allan deviation plot translation for different types of instrument noise (white noise, linear drift, and interpolated data). In addition, the useful application of using an Allan deviation to optimize and predict the performance of different calibration schemes will be presented. Even though this presentation will use the specific example of the Picarro G2401 CRDS Analyzer for atmospheric monitoring, the objective is to present the information such that it can be successfully applied to other instrument sets and disciplines. [1] D.W. Allan, "Statistics of Atomic Frequency Standards," Proc, IEEE, vol. 54, pp 221-230, Feb 1966 [2] P. Werle, R. Miicke, F. Slemr, "The Limits

  7. Non-haemodynamic anti-anginal agents in the management of patients with stable coronary artery disease and diabetes: A review of the evidence.

    PubMed

    Ambrosio, Giuseppe; Tamargo, Juan; Grant, Peter J

    2016-03-01

    Patients with coronary artery disease and concomitant diabetes mellitus tend to have more extensive vessel disease than non-diabetes mellitus coronary artery disease patients, are at high risk of adverse cardiovascular events and suffer from a great anginal burden. Very few trials have specifically addressed the issue of optimal anti-anginal therapy in coronary artery disease patients who also have diabetes mellitus. Among 'classical' anti-anginal agents, recent guidelines do not specifically recommend any molecule over others; however, European Society of Cardiology guidelines acknowledge that favourable data in patients with concomitant diabetes mellitus and coronary artery disease are available for trimetazidine and ranolazine, two anti-anginal agents with a non-haemodynamic mechanism of action. The aim of this article is to review available evidence supporting the anti-anginal efficacy of these two drugs in the difficult-to-treat population of diabetes mellitus patients, including their effects on glycated haemoglobin (HbA1c), a measure of medium-term glycaemic control. Although direct head-to-head comparisons have not been performed, available evidence favours ranolazine as an effective anti-anginal agent over trimetazidine in this population. In addition, ranolazine lowers HbA1c, indicating that it may improve glycaemic control in patients with diabetes mellitus. Conversely, scanty data are available on the metabolic effects of trimetazidine in this cohort of patients. Thus, ranolazine may represent a valuable therapeutic option in stable coronary artery disease patients with diabetes mellitus. © The Author(s) 2015.

  8. Probability distributions of continuous measurement results for conditioned quantum evolution

    NASA Astrophysics Data System (ADS)

    Franquet, A.; Nazarov, Yuli V.

    2017-02-01

    We address the statistics of continuous weak linear measurement on a few-state quantum system that is subject to a conditioned quantum evolution. For a conditioned evolution, both the initial and final states of the system are fixed: the latter is achieved by the postselection in the end of the evolution. The statistics may drastically differ from the nonconditioned case, and the interference between initial and final states can be observed in the probability distributions of measurement outcomes as well as in the average values exceeding the conventional range of nonconditioned averages. We develop a proper formalism to compute the distributions of measurement outcomes, and evaluate and discuss the distributions in experimentally relevant setups. We demonstrate the manifestations of the interference between initial and final states in various regimes. We consider analytically simple examples of nontrivial probability distributions. We reveal peaks (or dips) at half-quantized values of the measurement outputs. We discuss in detail the case of zero overlap between initial and final states demonstrating anomalously big average outputs and sudden jump in time-integrated output. We present and discuss the numerical evaluation of the probability distribution aiming at extending the analytical results and describing a realistic experimental situation of a qubit in the regime of resonant fluorescence.

  9. Continuous joint measurement and entanglement of qubits in remote cavities

    NASA Astrophysics Data System (ADS)

    Motzoi, Felix; Whaley, K. Birgitta; Sarovar, Mohan

    2015-09-01

    We present a first-principles theoretical analysis of the entanglement of two superconducting qubits in spatially separated microwave cavities by a sequential (cascaded) probe of the two cavities with a coherent mode, that provides a full characterization of both the continuous measurement induced dynamics and the entanglement generation. We use the SLH formalism to derive the full quantum master equation for the coupled qubits and cavities system, within the rotating wave and dispersive approximations, and conditioned equations for the cavity fields. We then develop effective stochastic master equations for the dynamics of the qubit system in both a polaronic reference frame and a reduced representation within the laboratory frame. We compare simulations with and analyze tradeoffs between these two representations, including the onset of a non-Markovian regime for simulations in the reduced representation. We provide conditions for ensuring persistence of entanglement and show that using shaped pulses enables these conditions to be met at all times under general experimental conditions. The resulting entanglement is shown to be robust with respect to measurement imperfections and loss channels. We also study the effects of qubit driving and relaxation dynamics during a weak measurement, as a prelude to modeling measurement-based feedback control in this cascaded system.

  10. Measurement of Continuous-Energy Neutron-Incident Neutron-Production Cross Section

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shigyo, Nobuhiro; Kunieda, Satoshi; Watanabe, Takehito

    Continuous energy neutron-incident neutron-production double differential cross sections were measured at the Weapons Neutron Research (WNR) facility of the Los Alamos Neutron Science Center. The energy of emitted neutrons was derived from the energy deposition in a detector. The incident-neutron energy was obtained by the time-of-flight method between the spallation target of WNR and the emitted neutron detector. Two types of detectors were adopted to measure the wide energy range of neutrons. The liquid organic scintillators covered up to 100 MeV. The recoil proton detectors that constitute the recoil proton radiator and phoswich type NaI (Tl) scintillators were used formore » neutrons above several tens of MeV. Iron and lead were used as sample materials. The experimental data were compared with the evaluated nuclear data, the results of GNASH, JQMD, and PHITS codes.« less

  11. An Automated and Continuous Plant Weight Measurement System for Plant Factory

    PubMed Central

    Chen, Wei-Tai; Yeh, Yu-Hui F.; Liu, Ting-Yu; Lin, Ta-Te

    2016-01-01

    In plant factories, plants are usually cultivated in nutrient solution under a controllable environment. Plant quality and growth are closely monitored and precisely controlled. For plant growth evaluation, plant weight is an important and commonly used indicator. Traditional plant weight measurements are destructive and laborious. In order to measure and record the plant weight during plant growth, an automated measurement system was designed and developed herein. The weight measurement system comprises a weight measurement device and an imaging system. The weight measurement device consists of a top disk, a bottom disk, a plant holder and a load cell. The load cell with a resolution of 0.1 g converts the plant weight on the plant holder disk to an analog electrical signal for a precise measurement. The top disk and bottom disk are designed to be durable for different plant sizes, so plant weight can be measured continuously throughout the whole growth period, without hindering plant growth. The results show that plant weights measured by the weight measurement device are highly correlated with the weights estimated by the stereo-vision imaging system; hence, plant weight can be measured by either method. The weight growth of selected vegetables growing in the National Taiwan University plant factory were monitored and measured using our automated plant growth weight measurement system. The experimental results demonstrate the functionality, stability and durability of this system. The information gathered by this weight system can be valuable and beneficial for hydroponic plants monitoring research and agricultural research applications. PMID:27066040

  12. An Automated and Continuous Plant Weight Measurement System for Plant Factory.

    PubMed

    Chen, Wei-Tai; Yeh, Yu-Hui F; Liu, Ting-Yu; Lin, Ta-Te

    2016-01-01

    In plant factories, plants are usually cultivated in nutrient solution under a controllable environment. Plant quality and growth are closely monitored and precisely controlled. For plant growth evaluation, plant weight is an important and commonly used indicator. Traditional plant weight measurements are destructive and laborious. In order to measure and record the plant weight during plant growth, an automated measurement system was designed and developed herein. The weight measurement system comprises a weight measurement device and an imaging system. The weight measurement device consists of a top disk, a bottom disk, a plant holder and a load cell. The load cell with a resolution of 0.1 g converts the plant weight on the plant holder disk to an analog electrical signal for a precise measurement. The top disk and bottom disk are designed to be durable for different plant sizes, so plant weight can be measured continuously throughout the whole growth period, without hindering plant growth. The results show that plant weights measured by the weight measurement device are highly correlated with the weights estimated by the stereo-vision imaging system; hence, plant weight can be measured by either method. The weight growth of selected vegetables growing in the National Taiwan University plant factory were monitored and measured using our automated plant growth weight measurement system. The experimental results demonstrate the functionality, stability and durability of this system. The information gathered by this weight system can be valuable and beneficial for hydroponic plants monitoring research and agricultural research applications.

  13. Ten-year results of the Freedom Solo stentless heart valve: excellent haemodynamics but progressive valve dysfunction in the long term.

    PubMed

    Sponga, Sandro; Barbera, Mila Della; Pavoni, Daisy; Lechiancole, Andrea; Mazzaro, Enzo; Valente, Marialuisa; Nucifora, Gaetano; Thiene, Gaetano; Livi, Ugolino

    2017-05-01

    Freedom Solo (FS) is a pericardial stentless heart valve showing excellent haemodynamic performance at mid-term. The aim of this study was to evaluate the long-term performance of such bioprostheses. Between December 2004 and November 2009, 109 patients (31 men; mean age 76 ± 6 years) underwent aortic valve replacement with FS. Preoperatively, the mean NYHA class was 2.5 ± 0.7, the mean EuroSCORE II, 2.8 ± 2.5. Mean prosthesis size was 22.7 ± 1.9 mm; concomitant procedures were performed in 65 patients. Structural valve deterioration (SVD) was diagnosed according to the Valve Academic Research Consortium-2 definition. Two patients (1.8%) died within 30 days. Follow-up (72 ± 36 months) was 100% completed. The 1-, 5- and 10-year actuarial survival rates were 89, 73 and 42%, respectively, with 8 valve-related deaths; the actuarial freedom from SVD was 99, 93 and 76%. During 61 ± 39 months of follow-up, echocardiographic findings worsened progressively: At discharge, 3-5 and 7-9 years, the mean gradient was 8 ± 4, 12 ± 11 and 19 ± 19 mmHg ( P  < 0.01); the indexed effective orifice area was 1.0 ± 0.2, 0.9 ± 0.2 and 0.8 ± 0.3 cm 2 /m 2 ( P  < 0.01). Of the 13 patients who developed SVD, it was due to aortic stenosis in 11. SVD was a predictor of cardiovascular mortality at univariate analysis (HR 2.87, 1.12-7.29); 2 explanted prostheses showed massive calcium deposits with mean calcium and phosphorus contents of 234 ± 16 and 116 ± 7 mg/g dry weight, respectively. The FS bioprosthesis shows excellent mid-term clinical and haemodynamic results and offers an alternative to other valves, particularly in the case of a small aortic annulus. Worsening of FS performance was observed at late follow-up because of progressive SVD with stenosis, questioning whether it should be used in patients with a long life expectancy. © The Author 2017. Published by Oxford University Press on behalf of the

  14. Interferometer with Continuously Varying Path Length Measured in Wavelengths to the Reference Mirror

    NASA Technical Reports Server (NTRS)

    Ohara, Tetsuo (Inventor)

    2016-01-01

    An interferometer in which the path length of the reference beam, measured in wavelengths, is continuously changing in sinusoidal fashion and the interference signal created by combining the measurement beam and the reference beam is processed in real time to obtain the physical distance along the measurement beam between the measured surface and a spatial reference frame such as the beam splitter. The processing involves analyzing the Fourier series of the intensity signal at one or more optical detectors in real time and using the time-domain multi-frequency harmonic signals to extract the phase information independently at each pixel position of one or more optical detectors and converting the phase information to distance information.

  15. Continuous Wave Ring-Down Spectroscopy for Velocity Distribution Measurements in Plasma

    NASA Astrophysics Data System (ADS)

    McCarren, Dustin W.

    Cavity Ring-Down Spectroscopy CRDS is a proven, ultra-sensitive, cavity enhanced absorption spectroscopy technique. When combined with a continuous wavelength (CW) diode laser that has a sufficiently narrow line width, the Doppler broadened absorption line, i.e., the velocity distribution functions (VDFs) of the absorbing species, can be measured. Measurements of VDFs can be made using established techniques such as laser induced fluorescence (LIF). However, LIF suffers from the requirement that the initial state of the LIF sequence have a substantial density and that the excitation scheme fluoresces at an easily detectable wavelength. This usually limits LIF to ions and atoms with large metastable state densities for the given plasma conditions. CW-CRDS is considerably more sensitive than LIF and can potentially be applied to much lower density populations of ion and atom states. Also, as a direct absorption technique, CW-CRDS measurements only need to be concerned with the species' absorption wavelength and provide an absolute measure of the line integrated initial state density. Presented in this work are measurements of argon ion and neutral VDFs in a helicon plasma using CW-CRDS and LIF.

  16. Continuous monitoring of kidney transplant perfusion with near-infrared spectroscopy.

    PubMed

    Malakasioti, Georgia; Marks, Stephen D; Watson, Tom; Williams, Fariba; Taylor-Allkins, Mariesa; Mamode, Nizam; Morgan, Justin; Hayes, Wesley N

    2018-05-11

    Current reliance on clinical, laboratory and Doppler ultrasound (DUS) parameters for monitoring kidney transplant perfusion in the immediate post-operative period in children risks late recognition of allograft hypoperfusion and vascular complications. Near-infrared spectroscopy (NIRS) is a real-time, non-invasive technique for monitoring tissue oxygenation percutaneously. NIRS monitoring of kidney transplant perfusion has not previously been validated to the gold standard of DUS. We examined whether NIRS tissue oxygenation indices can reliably assess blood flow in established paediatric kidney transplants. Paediatric kidney transplant recipients ages 1-18 years with stable allograft function were eligible. Participants underwent routine DUS assessment of kidney transplant perfusion, including resistive index (RI) and peak systolic velocity at the upper and lower poles. NIRS data [tissue oxygenation index (TOI%)] were recorded for a minimum of 2 min with NIRS sensors placed on the skin over upper and lower allograft poles. Twenty-nine subjects with a median age of 13.3 (range 4.8-17.8) years and a median transplant vintage of 26.5 months participated. Thirteen (45%) were female and 20 (69%) were living donor kidney recipients. NIRS monitoring was well tolerated by all, with 96-100% valid measurements. Significant negative correlations were observed between NIRS TOI% and DUS RI at both the upper and lower poles (r = -0.4 and -0.6, P = 0.04 and 0.001, respectively). Systolic blood pressure but not estimated glomerular filtration rate also correlated with NIRS TOI% (P = 0.01). NIRS indices correlate well with DUS perfusion and haemodynamic parameters in established paediatric kidney transplant recipients. Further studies are warranted to extend NIRS use for continuous real-time monitoring of early post-transplant perfusion status.

  17. Childhood Obesity Associates Haemodynamic and Vascular Changes That Result in Increased Central Aortic Pressure with Augmented Incident and Reflected Wave Components, without Changes in Peripheral Amplification

    PubMed Central

    Castro, Juan M.; García-Espinosa, Victoria; Curcio, Santiago; Arana, Maite; Chiesa, Pedro; Giachetto, Gustavo; Zócalo, Yanina; Bia, Daniel

    2016-01-01

    The aims were to determine if childhood obesity is associated with increased central aortic blood pressure (BP) and to characterize haemodynamic and vascular changes associated with BP changes in obese children and adolescents by means of analyzing changes in cardiac output (stroke volume, SV), arterial stiffness (aortic pulse wave velocity, PWV), peripheral vascular resistances (PVR), and net and relative contributions of reflected waves to the aortic pulse wave amplitude. We included 117 subjects (mean/range age: 10 (5–15) years, 49 females), who were obese (OB) or had normal weight (NW). Peripheral and central aortic BP, PWV, and pulse wave-derived parameters (augmentation index, amplitude of forward and backward components) were measured with tonometry (SphygmoCor) and oscillometry (Mobil-O-Graph). With independence of the presence of dyslipidemia, hypertension, or sedentarism, the aortic systolic and pulse BP were higher in OB than in NW subjects. The increase in central BP could not be explained by the elevation in the relative contribution of reflections to the aortic pressure wave and higher PVR or by an augmented peripheral reflection coefficient. Instead, the rise in central BP could be explained by an increase in the amplitude of both incident and reflect wave components associated to augmented SV and/or PWV. PMID:26881081

  18. Relationships between Continuous Performance Task Scores and Other Cognitive Measures: Causality or Commonality?

    ERIC Educational Resources Information Center

    Aylward, Glen P.; Gordon, Michael; Verhulst, Steven J.

    1997-01-01

    Relationships among continuous performance test (CPT), IQ, achievement, and memory/learning scores were explored for 1,280 children about 9 years old. Associations among the CPT measures and various cognitive/academic tasks suggest that all require attention and inhibition. The importance of assessing attention and disinhibition in psychological…

  19. Anaesthesia for laparoscopic nephrectomy: Does end-tidal carbon dioxide measurement correlate with arterial carbon dioxide measurement?

    PubMed

    Jayan, Nithin; Jacob, Jaya Susan; Mathew, Mohan

    2018-04-01

    Not many studies have explored the correlation between arterial carbon dioxide tension (PaCO 2 ) and end-tidal carbon dioxide tension (ETCO 2 ) in surgeries requiring pneumoperitoneum of more than 1 hour duration with the patient in non-supine position. The aim of our study was to evaluate the correlation of ETCO 2 with PaCO 2 in patients undergoing laparoscopic nephrectomy under general anaesthesia. A descriptive study was performed in thirty patients undergoing laparoscopic nephrectomy from September 2014 to August 2015. The haemodynamic parameters, minute ventilation, PaCO 2 and ETCO 2 measured at three predetermined points during the procedure were analysed. Correlation was checked using Pearson's Correlation Coefficient Test. P <0.05 was considered statistically significant. Statistical analysis of the values showed a positive correlation between ETCO 2 and PaCO 2 ( P < 0.05). Following carbon dioxide insufflation, both ETCO 2 and PaCO 2 increased by 5.4 and 6.63 mmHg, respectively, at the end of the 1 st hour. The PaCO 2 -ETCO 2 gradient was found to increase during the 1 st hour following insufflation (4.07 ± 2.05 mmHg); it returned to the pre-insufflation values in another hour (2.93 ± 1.43 mmHg). Continuous ETCO 2 monitoring is a reliable indicator of the trend in arterial CO 2 fluctuations in the American Society of Anesthesiologists Grades 1 and 2 patients undergoing laparoscopic nephrectomy under general anaesthesia.

  20. A comparison of the clinical, haemodynamic and angiographic features in right ventricular endomyocardial fibrosis and Ebstein's anomaly of the tricuspid valve.

    PubMed

    Balakrishnan, K G; Sapru, R P; Sasidharan, K; Venkitachalam, C G

    1982-01-01

    The clinical, haemodynamic and angiographic features of 18 patients with right ventricular endomyocardial fibrosis (RVEMF) and 8 patients with Ebstein's anomaly of the tricuspid valve (EATV) have been compared. Diagnosis was confirmed by selective angiography. The position of the tricuspid annulus was identified from selective right ventricular angiograms and confirmed by selective right coronary angiography. In 83% of RVEMF patients the tricuspid annulus was displaced to the left of the spine. A false impression of displacement of the tricuspid leaflet can thus be created. However, a tricuspid leaflet displaced away from the tricuspid annulus was found only in patients with EATV. A considerable overlap exists between the wide spectrum of clinical presentations of the two conditions. Helpful distinguishing features that favour EATV were, the presence of a scratchy diastolic murmur and polyphasic QRS complexes in the ECG. Atrial fibrillation in the ECG, and myocardial calcification or pericardial effusion, whenever present, favour RVEMF.

  1. Probing quantumness with joint continuous measurements of non-commuting qubit observables

    NASA Astrophysics Data System (ADS)

    Garcia-Pintos, Luis Pedro; Dressel, Justin

    In this talk we consider continuous weak measurements as a means to probe foundational issues in quantum mechanics. We consider the simultaneous monitoring of two noncommuting observables-as recently implemented by the Siddiqi group at UC Berkeley. Contrary to naive expectation, the output of such experiment can be used to simultaneously track the approximate observable dynamics. Despite this seeming realism, we also show that the readouts violate macrorealistic Leggett-Garg inequalities for arbitrarily short temporal correlations, and that the derived inequalities are manifestly violated even in the absence of Hamiltonian evolution. Such violations should indicate the failure of at least one postulate of macrorealism: either physical quantities do not have well defined values at all times, or the measurement process itself disturbs what is being measured. Despite this macrorealism violation, we construct a realistic, but epistemically restricted, model that perfectly emulates both the qubit evolution and the observed noisy signals, thus also emulating the violations.

  2. Estimation of an accuracy index of a diagnostic biomarker when the reference biomarker is continuous and measured with error.

    PubMed

    Wu, Mixia; Zhang, Dianchen; Liu, Aiyi

    2016-01-01

    New biomarkers continue to be developed for the purpose of diagnosis, and their diagnostic performances are typically compared with an existing reference biomarker used for the same purpose. Considerable amounts of research have focused on receiver operating characteristic curves analysis when the reference biomarker is dichotomous. In the situation where the reference biomarker is measured on a continuous scale and dichotomization is not practically appealing, an index was proposed in the literature to measure the accuracy of a continuous biomarker, which is essentially a linear function of the popular Kendall's tau. We consider the issue of estimating such an accuracy index when the continuous reference biomarker is measured with errors. We first investigate the impact of measurement errors on the accuracy index, and then propose methods to correct for the bias due to measurement errors. Simulation results show the effectiveness of the proposed estimator in reducing biases. The methods are exemplified with hemoglobin A1c measurements obtained from both the central lab and a local lab to evaluate the accuracy of the mean data obtained from the metered blood glucose monitoring against the centrally measured hemoglobin A1c from a behavioral intervention study for families of youth with type 1 diabetes.

  3. Measuring a critical stress for continuous prevention of marine biofouling accumulation with aeration.

    PubMed

    Menesses, Mark; Belden, Jesse; Dickenson, Natasha; Bird, James

    2017-10-01

    When cleaning the hull of a ship, significant shear stresses are needed to remove established biofouling organisms. Given that there exists a link between the amount of time that fouling accumulates and the stress required to remove it, it is not surprising that more frequent grooming requires less shear stress. Yet, it is unclear if there is a minimum stress needed to prevent the growth of macrofouling in the limit of continuous grooming. This manuscript shows that single bubble stream aeration provides continuous grooming and prevents biofouling accumulation in regions where the average wall stress exceeds ~0.01 Pa. This value was found by comparing observations of biofouling growth from field studies with complementary laboratory measurements that probe the associated flow fields. These results suggest that aeration and other continuous grooming systems must exceed a wall stress of 0.01 Pa to prevent macrofouling accumulation.

  4. Robust shot-noise measurement for continuous-variable quantum key distribution

    NASA Astrophysics Data System (ADS)

    Kunz-Jacques, Sébastien; Jouguet, Paul

    2015-02-01

    We study a practical method to measure the shot noise in real time in continuous-variable quantum key distribution systems. The amount of secret key that can be extracted from the raw statistics depends strongly on this quantity since it affects in particular the computation of the excess noise (i.e., noise in excess of the shot noise) added by an eavesdropper on the quantum channel. Some powerful quantum hacking attacks relying on faking the estimated value of the shot noise to hide an intercept and resend strategy were proposed. Here, we provide experimental evidence that our method can defeat the saturation attack and the wavelength attack.

  5. INVESTIGATION OF A SYSTEMATIC OFFSET IN THE MEASUREMENT OF ORGANIC CARBON WITH A SEMI-CONTINUOUS ANALYZER

    EPA Science Inventory

    Organic carbon was measured semi-continuously in laboratory experiments of steady-state secondary organic aerosol formed by hydrocarbon + NOx irradiations. Examination of the mass of carbon measured on the filter for various sample volumes reveals a systematic offset that is not...

  6. Passive continuous positive airway pressure ventilation during cardiopulmonary resuscitation: a randomized cross-over manikin simulation study.

    PubMed

    Winkler, Bernd E; Muellenbach, Ralf M; Wurmb, Thomas; Struck, Manuel F; Roewer, Norbert; Kranke, Peter

    2017-02-01

    While controlled ventilation is most frequently used during cardiopulmonary resuscitation (CPR), the application of continuous positive airway pressure (CPAP) and passive ventilation of the lung synchronously with chest compressions and decompressions might represent a promising alternative approach. One benefit of CPAP during CPR is the reduction of peak airway pressures and therefore a potential enhancement in haemodynamics. We therefore evaluated the tidal volumes and airway pressures achieved during CPAP-CPR. During CPR with the LUCAS™ 2 compression device, a manikin model was passively ventilated at CPAP levels of 5, 10, 20 and 30 hPa with the Boussignac tracheal tube and the ventilators Evita ® V500, Medumat ® Transport, Oxylator ® EMX, Oxylog ® 2000, Oxylog ® 3000, Primus ® and Servo ® -i as well as the Wenoll ® diver rescue system. Tidal volumes and airway pressures during CPAP-CPR were recorded and analyzed. Tidal volumes during CPAP-CPR were higher than during compression-only CPR without positive airway pressure. The passively generated tidal volumes increased with increasing CPAP levels and were significantly influenced by the ventilators used. During ventilation at 20 hPa CPAP via a tracheal tube, the mean tidal volumes ranged from 125 ml (Medumat ® ) to 309 ml (Wenoll ® ) and the peak airway pressures from 23 hPa (Primus ® ) to 49 hPa (Oxylog ® 3000). Transport ventilators generated lower tidal volumes than intensive care ventilators or closed-circuit systems. Peak airway pressures during CPAP-CPR were lower than those during controlled ventilation CPR reported in literature. High peak airway pressures are known to limit the applicability of ventilation via facemask or via supraglottic airway devices and may adversely affect haemodynamics. Hence, the application of ventilators generating high tidal volumes with low peak airway pressures appears desirable during CPAP-CPR. The limited CPAP-CPR capabilities of transport ventilators in

  7. Protective sheath for a continuous measurement thermocouple

    DOEpatents

    Phillippi, R.M.

    1991-12-03

    Disclosed is a protective thermocouple sheath of a magnesia graphite refractory material for use in continuous temperature measurements of molten metal in a metallurgical ladle and having a basic slag layer thereon. The sheath includes an elongated torpedo-shaped sheath body formed of a refractory composition and having an interior borehole extending axially therethrough and adapted to receive a thermocouple. The sheath body includes a lower end which is closed about the borehole and forms a narrow, tapered tip. The sheath body also includes a first body portion integral with the tapered tip and having a relatively constant cross section and providing a thin wall around the borehole. The sheath body also includes a second body portion having a relatively constant cross section larger than the cross section of the first body portion and providing a thicker wall around the borehole. The borehole terminates in an open end at the second body portion. The tapered tip is adapted to penetrate the slag layer and the thicker second body portion and its magnesia constituent material are adapted to withstand chemical attack thereon from the slag layer. The graphite constituent improves thermal conductivity of the refractory material and, thus, enhances the thermal responsiveness of the device. 4 figures.

  8. Protective sheath for a continuous measurement thermocouple

    DOEpatents

    Phillippi, R. Michael

    1991-01-01

    Disclosed is a protective thermocouple sheath of a magnesia graphite refractory material for use in continuous temperature measurements of molten metal in a metallurgical ladle and having a basic slag layer thereon. The sheath includes an elongated torpedo-shaped sheath body formed of a refractory composition and having an interior borehole extending axially therethrough and adapted to receive a thermocouple. The sheath body includes a lower end which is closed about the borehole and forms a narrow, tapered tip. The sheath body also includes a first body portion integral with the tapered tip and having a relatively constant cross section and providing a thin wall around the borehole. The sheath body also includes a second body portion having a relatively constant cross section larger than the cross section of the first body portion and providing a thicker wall around the borehole. The borehole terminates in an open end at the second body portion. The tapered tip is adapted to penetrate the slag layer and the thicker second body portion and its magnesia constituent material are adapted to withstand chemical attack thereon from the slag layer. The graphite constituent improves thermal conductivity of the refractory material and, thus, enhances the thermal responsiveness of the device.

  9. Validation of 2 New Measures of Continuity of Care Based on Year-to-Year Follow-up With Known Providers of Health Care

    PubMed Central

    Tousignant, Pierre; Diop, Mamadou; Fournier, Michel; Roy, Yves; Haggerty, Jeannie; Hogg, William; Beaulieu, Marie-Dominique

    2014-01-01

    PURPOSE In a primary care context favoring group practices, we assessed the validity of 2 new continuity measures (both versions of known provider continuity, KPC) that capture the concentration of care over time from multiple physicians (multiple provider continuity, KPC-MP) or from the physician seen most often (personal provider continuity, KPC-PP). METHODS Patients with diabetes or cardiovascular disease (N = 765) were approached in the waiting rooms of 28 primary care clinics in 3 regions of the province of Quebec, Canada; answered a survey questionnaire measuring relational continuity, interpersonal communication, coordination within the clinic, coordination with specialists, and overall coordination; and gave permission for their medical records to be reviewed and their medical services utilization data for the previous 2 years to be accessed to measure KPC. Using generalized linear mixed models, we assessed the association between KPC and the patients’ responses. RESULTS Among the 5 different patient-reported measures or their combination, KPC-MP was significantly related with overall coordination of care: for high continuity, the odds ratio (OR) = 2.02 (95% CI, 1.33–3.07), and for moderate continuity, OR = 1.61 (95% CI, 1.06–2.46). KPC-MP was also related with the combined continuity score: for high continuity, OR = 1.52 (95% CI, 1.11–2.09), and for moderate continuity, OR = 1.48 (95% CI, 1.10–2.00). KPC-PP was not significantly associated with any of the survey measures. CONCLUSIONS The KPC-MP measure, based on readily available administrative data, is associated with patient-perceived overall coordination of care among multiple physicians. KPC measures are potentially a valuable and low-cost way to follow the effects of changes favoring group practice on continuity of care for entire populations. They are easy to replicate over time and across jurisdictions. PMID:25384820

  10. Investigating Einstein-Podolsky-Rosen steering of continuous-variable bipartite states by non-Gaussian pseudospin measurements

    NASA Astrophysics Data System (ADS)

    Xiang, Yu; Xu, Buqing; Mišta, Ladislav; Tufarelli, Tommaso; He, Qiongyi; Adesso, Gerardo

    2017-10-01

    Einstein-Podolsky-Rosen (EPR) steering is an asymmetric form of correlations which is intermediate between quantum entanglement and Bell nonlocality, and can be exploited as a resource for quantum communication with one untrusted party. In particular, steering of continuous-variable Gaussian states has been extensively studied theoretically and experimentally, as a fundamental manifestation of the EPR paradox. While most of these studies focused on quadrature measurements for steering detection, two recent works revealed that there exist Gaussian states which are only steerable by suitable non-Gaussian measurements. In this paper we perform a systematic investigation of EPR steering of bipartite Gaussian states by pseudospin measurements, complementing and extending previous findings. We first derive the density-matrix elements of two-mode squeezed thermal Gaussian states in the Fock basis, which may be of independent interest. We then use such a representation to investigate steering of these states as detected by a simple nonlinear criterion, based on second moments of the correlation matrix constructed from pseudospin operators. This analysis reveals previously unexplored regimes where non-Gaussian measurements are shown to be more effective than Gaussian ones to witness steering of Gaussian states in the presence of local noise. We further consider an alternative set of pseudospin observables, whose expectation value can be expressed more compactly in terms of Wigner functions for all two-mode Gaussian states. However, according to the adopted criterion, these observables are found to be always less sensitive than conventional Gaussian observables for steering detection. Finally, we investigate continuous-variable Werner states, which are non-Gaussian mixtures of Gaussian states, and find that pseudospin measurements are always more effective than Gaussian ones to reveal their steerability. Our results provide useful insights on the role of non

  11. Hybrid diffuse optical techniques for continuous hemodynamic measurement in gastrocnemius during plantar flexion exercise

    NASA Astrophysics Data System (ADS)

    Henry, Brad; Zhao, Mingjun; Shang, Yu; Uhl, Timothy; Thomas, D. Travis; Xenos, Eleftherios S.; Saha, Sibu P.; Yu, Guoqiang

    2015-12-01

    Occlusion calibrations and gating techniques have been recently applied by our laboratory for continuous and absolute diffuse optical measurements of forearm muscle hemodynamics during handgrip exercises. The translation of these techniques from the forearm to the lower limb is the goal of this study as various diseases preferentially affect muscles in the lower extremity. This study adapted a hybrid near-infrared spectroscopy and diffuse correlation spectroscopy system with a gating algorithm to continuously quantify hemodynamic responses of medial gastrocnemius during plantar flexion exercises in 10 healthy subjects. The outcomes from optical measurement include oxy-, deoxy-, and total hemoglobin concentrations, blood oxygen saturation, and relative changes in blood flow (rBF) and oxygen consumption rate (rV˙O2). We calibrated rBF and rV˙O2 profiles with absolute baseline values of BF and V˙O2 obtained by venous and arterial occlusions, respectively. Results from this investigation were comparable to values from similar studies. Additionally, significant correlation was observed between resting local muscle BF measured by the optical technique and whole limb BF measured concurrently by a strain gauge venous plethysmography. The extensive hemodynamic and metabolic profiles during exercise will allow for future comparison studies to investigate the diagnostic value of hybrid technologies in muscles affected by disease.

  12. Mobile Platforms for Continuous Spatial Measurements of Urban Trace Gases and Criteria Pollutants

    NASA Astrophysics Data System (ADS)

    Fasoli, B.; Mitchell, L.; Bares, R.; Crosman, E.; Bush, S. E.; Horel, J.; Lin, J. C.; Bowling, D. R.; Ehleringer, J. R.

    2015-12-01

    Surface-based observations of atmospheric trace gases and criteria pollutants provide critical data on how emissions and pollutant concentrations vary over time. However, traditional stationary measurement sites only quantify concentrations at a single point in space, limiting our ability to understand spatial patterns. Using trace gas instrumentation capable of making continuous high-frequency (~1s) measurements, we have developed mobile platforms to complement stationary observation sites in order to better constrain the heterogeneity and complexities of urban emissions. These compact trace gas and criteria pollutant measurement systems are capable of precisely measuring CO2, CH4 PM2.5, O3, NOx, and several meteorological parameters on TRAX, Salt Lake City's light-rail system, and in a van-based mobile laboratory. Using case study observations, we discuss mobile measurement methodologies and the practical applications of mobile trace gas sampling platforms.

  13. Central and peripheral haemodynamic effects of non-steroidal anti-inflammatory drugs in man.

    PubMed

    Wennmalm, A; Carlsson, I; Edlund, A; Eriksson, S; Kaijser, L; Nowak, J

    1984-01-01

    The haemodynamic effects of non-steroidal anti-inflammatory (NSAI) drugs can be attributed either to their common property of inhibiting the formation of prostaglandins (PG) in the cardiovascular system, or to direct actions on the tone and sensitivity of the resistance vessels in various regions. Indomethacin (IND) is the most frequently studied NSAI drug, in animals and in man. Its cardiovascular effects differ somewhat from those of other NSAI, due to the fact that, besides inhibiting PG formation, IND acts as a direct vasoconstrictor. The stimulatory effect of IND in vascular smooth muscle results in an increased systemic vascular resistance which, although partially compensated by a decreased cardiac output, gives rise to a moderate increase in systemic blood pressure. The vasoconstrictor effect of IND is of particular interest in patients with ischemic heart disease, since it lowers their already decreased coronary flow, and may thereby accentuate the risk of myocardial infarction. Administration of IND also leads to a decreased blood flow in the splanchnic region, the kidneys, and the brain. The cerebral blood flow is lowered by 25-35%; in addition, IND almost entirely erases the hyperemic flow response to hypercapnia. Of other NSAI drugs, at least aspirin and naproxen are completely devoid of such actions on the cerebral circulation. A common vascular effect of all NSAI drugs is a diminution of reactive hyperemia, the local hyperemia that develops in a tissue subjected to a short period of arterial occlusion. Part of this hyperemic response is dependent on an intact vascular PG formation and consequently it is inhibited when PG formation is blocked. In contrast, NSAI drugs do not affect the functional increase in the blood flow in working skeletal muscle.

  14. Noninvasive and continuous blood pressure measurement via superficial temporal artery tonometry.

    PubMed

    Canning, Julia; Helbert, Kendall; Iashin, Grigoriy; Matthews, Jonathan; Yang, Jason; Delano, Margaret K; Sodini, Charles G; Quan Zhang

    2016-08-01

    The measurement of blood pressure is an important cardiovascular health assessment, yet the current set of methodologies is limited in resolution, repeatability, accuracy, simplicity, and safety. This paper presents the design and prototype implementation of a novel and easy-to-use medical device for noninvasive and continuous blood pressure monitoring through tonometry at the superficial temporal artery (STA). The device features a stable form factor inspired by over-ear headphones that adjusts easily from person to person using a combination prismatic and rotational joint. A stepper motor and pressure sensor, built into the device, apply a controlled force to flatten the artery and measure the wearer's blood pressure. The design is fully wireless, using Bluetooth communication to connect to a custom control and monitoring interface on the user's laptop that allows for easy calibration and real-time measurement. Preliminary testing of the device showed a percentage error from a blood pressure cuff mean arterial pressure measurement of 7.7% (7.0 mmHg). This was also compared to a Nexfin vascular unloading device, which showed a percentage error from the blood pressure cuff of 7.3% (6.6 mmHg).

  15. Mapping human preictal and ictal haemodynamic networks using simultaneous intracranial EEG-fMRI

    PubMed Central

    Chaudhary, Umair J.; Centeno, Maria; Thornton, Rachel C.; Rodionov, Roman; Vulliemoz, Serge; McEvoy, Andrew W.; Diehl, Beate; Walker, Matthew C.; Duncan, John S.; Carmichael, David W.; Lemieux, Louis

    2016-01-01

    Accurately characterising the brain networks involved in seizure activity may have important implications for our understanding of epilepsy. Intracranial EEG-fMRI can be used to capture focal epileptic events in humans with exquisite electrophysiological sensitivity and allows for identification of brain structures involved in this phenomenon over the entire brain. We investigated ictal BOLD networks using the simultaneous intracranial EEG-fMRI (icEEG-fMRI) in a 30 year-old male undergoing invasive presurgical evaluation with bilateral depth electrode implantations in amygdalae and hippocampi for refractory temporal lobe epilepsy. One spontaneous focal electrographic seizure was recorded. The aims of the data analysis were firstly to map BOLD changes related to the ictal activity identified on icEEG and secondly to compare different fMRI modelling approaches. Visual inspection of the icEEG showed an onset dominated by beta activity involving the right amygdala and hippocampus lasting 6.4 s (ictal onset phase), followed by gamma activity bilaterally lasting 14.8 s (late ictal phase). The fMRI data was analysed using SPM8 using two modelling approaches: firstly, purely based on the visually identified phases of the seizure and secondly, based on EEG spectral dynamics quantification. For the visual approach the two ictal phases were modelled as ‘ON’ blocks convolved with the haemodynamic response function; in addition the BOLD changes during the 30 s preceding the onset were modelled using a flexible basis set. For the quantitative fMRI modelling approach two models were evaluated: one consisting of the variations in beta and gamma bands power, thereby adding a quantitative element to the visually-derived models, and another based on principal components analysis of the entire spectrogram in attempt to reduce the bias associated with the visual appreciation of the icEEG. BOLD changes related to the visually defined ictal onset phase were revealed in the medial

  16. Mapping human preictal and ictal haemodynamic networks using simultaneous intracranial EEG-fMRI.

    PubMed

    Chaudhary, Umair J; Centeno, Maria; Thornton, Rachel C; Rodionov, Roman; Vulliemoz, Serge; McEvoy, Andrew W; Diehl, Beate; Walker, Matthew C; Duncan, John S; Carmichael, David W; Lemieux, Louis

    2016-01-01

    Accurately characterising the brain networks involved in seizure activity may have important implications for our understanding of epilepsy. Intracranial EEG-fMRI can be used to capture focal epileptic events in humans with exquisite electrophysiological sensitivity and allows for identification of brain structures involved in this phenomenon over the entire brain. We investigated ictal BOLD networks using the simultaneous intracranial EEG-fMRI (icEEG-fMRI) in a 30 year-old male undergoing invasive presurgical evaluation with bilateral depth electrode implantations in amygdalae and hippocampi for refractory temporal lobe epilepsy. One spontaneous focal electrographic seizure was recorded. The aims of the data analysis were firstly to map BOLD changes related to the ictal activity identified on icEEG and secondly to compare different fMRI modelling approaches. Visual inspection of the icEEG showed an onset dominated by beta activity involving the right amygdala and hippocampus lasting 6.4 s (ictal onset phase), followed by gamma activity bilaterally lasting 14.8 s (late ictal phase). The fMRI data was analysed using SPM8 using two modelling approaches: firstly, purely based on the visually identified phases of the seizure and secondly, based on EEG spectral dynamics quantification. For the visual approach the two ictal phases were modelled as 'ON' blocks convolved with the haemodynamic response function; in addition the BOLD changes during the 30 s preceding the onset were modelled using a flexible basis set. For the quantitative fMRI modelling approach two models were evaluated: one consisting of the variations in beta and gamma bands power, thereby adding a quantitative element to the visually-derived models, and another based on principal components analysis of the entire spectrogram in attempt to reduce the bias associated with the visual appreciation of the icEEG. BOLD changes related to the visually defined ictal onset phase were revealed in the medial and

  17. Pulse Oximeter Derived Blood Pressure Measurement in Patients With a Continuous Flow Left Ventricular Assist Device.

    PubMed

    Hellman, Yaron; Malik, Adnan S; Lane, Kathleen A; Shen, Changyu; Wang, I-Wen; Wozniak, Thomas C; Hashmi, Zubair A; Munson, Sarah D; Pickrell, Jeanette; Caccamo, Marco A; Gradus-Pizlo, Irmina; Hadi, Azam

    2017-05-01

    Currently, blood pressure (BP) measurement is obtained noninvasively in patients with continuous flow left ventricular assist device (LVAD) by placing a Doppler probe over the brachial or radial artery with inflation and deflation of a manual BP cuff. We hypothesized that replacing the Doppler probe with a finger-based pulse oximeter can yield BP measurements similar to the Doppler derived mean arterial pressure (MAP). We conducted a prospective study consisting of patients with contemporary continuous flow LVADs. In a small pilot phase I inpatient study, we compared direct arterial line measurements with an automated blood pressure (ABP) cuff, Doppler and pulse oximeter derived MAP. Our main phase II study included LVAD outpatients with a comparison between Doppler, ABP, and pulse oximeter derived MAP. A total of five phase I and 36 phase II patients were recruited during February-June 2014. In phase I, the average MAP measured by pulse oximeter was closer to arterial line MAP rather than Doppler (P = 0.06) or ABP (P < 0.01). In phase II, pulse oximeter MAP (96.6 mm Hg) was significantly closer to Doppler MAP (96.5 mm Hg) when compared to ABP (82.1 mm Hg) (P = 0.0001). Pulse oximeter derived blood pressure measurement may be as reliable as Doppler in patients with continuous flow LVADs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  18. Challenges and Opportunities of Long-Term Continuous Stream Metabolism Measurements at the National Ecological Observatory Network

    NASA Astrophysics Data System (ADS)

    Goodman, K. J.; Lunch, C. K.; Baxter, C.; Hall, R.; Holtgrieve, G. W.; Roberts, B. J.; Marcarelli, A. M.; Tank, J. L.

    2013-12-01

    Recent advances in dissolved oxygen sensing and modeling have made continuous measurements of whole-stream metabolism relatively easy to make, allowing ecologists to quantify and evaluate stream ecosystem health at expanded temporal and spatial scales. Long-term monitoring of continuous stream metabolism will enable a better understanding of the integrated and complex effects of anthropogenic change (e.g., land-use, climate, atmospheric deposition, invasive species, etc.) on stream ecosystem function. In addition to their value in the particular streams measured, information derived from long-term data will improve the ability to extrapolate from shorter-term data. With the need to better understand drivers and responses of whole-stream metabolism come difficulties in interpreting the results. Long-term trends will encompass physical changes in stream morphology and flow regime (e.g., variable flow conditions and changes in channel structure) combined with changes in biota. Additionally long-term data sets will require an organized database structure, careful quantification of errors and uncertainties, as well as propagation of error as a result of the calculation of metabolism metrics. Parsing of continuous data and the choice of modeling approaches can also have a large influence on results and on error estimation. The two main modeling challenges include 1) obtaining unbiased, low-error daily estimates of gross primary production (GPP) and ecosystem respiration (ER), and 2) interpreting GPP and ER measurements over extended time periods. The National Ecological Observatory Network (NEON), in partnership with academic and government scientists, has begun to tackle several of these challenges as it prepares for the collection and calculation of 30 years of continuous whole-stream metabolism data. NEON is a national-scale research platform that will use consistent procedures and protocols to standardize measurements across the United States, providing long

  19. A novel wearable device for continuous, non-invasion blood pressure measurement.

    PubMed

    Xin, Qin; Wu, Jianping

    2017-08-01

    In this paper, we have developed a wearable cuffless device for daily blood pressure (BP) measurement. We incorporated the light based sensor and other hard wares in a small volume for BP detection. With optimized algorithm, the real-time BP reading could be achieved, the data could be presented in the screen and be transmitted by internet of things (IoT) for history data comparison and multi-terminal viewing. Thus, further analysis provides the probability for diet or sports suggestion and alarm. We have measured BP from more than 60 subjects, compare to traditional mercury blood pressure meter, no obvious error in both systolic blood pressure (SBP) and diastolic blood pressure (DBP) are detected. Such device can be used for continues non-invasion BP detection, and further data docking and health analysis could be achieved. Copyright © 2017. Published by Elsevier Ltd.

  20. Non-invasive continuous blood pressure measurement based on mean impact value method, BP neural network, and genetic algorithm.

    PubMed

    Tan, Xia; Ji, Zhong; Zhang, Yadan

    2018-04-25

    Non-invasive continuous blood pressure monitoring can provide an important reference and guidance for doctors wishing to analyze the physiological and pathological status of patients and to prevent and diagnose cardiovascular diseases in the clinical setting. Therefore, it is very important to explore a more accurate method of non-invasive continuous blood pressure measurement. To address the shortcomings of existing blood pressure measurement models based on pulse wave transit time or pulse wave parameters, a new method of non-invasive continuous blood pressure measurement - the GA-MIV-BP neural network model - is presented. The mean impact value (MIV) method is used to select the factors that greatly influence blood pressure from the extracted pulse wave transit time and pulse wave parameters. These factors are used as inputs, and the actual blood pressure values as outputs, to train the BP neural network model. The individual parameters are then optimized using a genetic algorithm (GA) to establish the GA-MIV-BP neural network model. Bland-Altman consistency analysis indicated that the measured and predicted blood pressure values were consistent and interchangeable. Therefore, this algorithm is of great significance to promote the clinical application of a non-invasive continuous blood pressure monitoring method.

  1. Continuous cytokine haemoadsorption incorporated into a venoarterial ECMO circuit for the management of postcardiotomy cardiogenic and septic shock - a case report.

    PubMed

    Nemeth, Endre; Szigeti, Szabolcs; Varga, Tamas; Daroczi, Laszlo; Barati, Zoltan; Merkely, Bela; Gal, Janos

    2018-05-01

    The acute surgical treatment of infective endocarditis (IE) carries a high risk of postoperative mortality. Most complications are linked to uncontrolled sepsis and inflammatory processes. Cytokine haemoadsorption is an extracorporeal technique which has benefits reported in haemodynamic stability and inflammatory response. A 46-year-old male patient underwent emergency cardiac surgery due to progressive IE. Postcardiotomy cardiogenic shock associated with cardiac surgery required the implantation of venoarterial (VA)-ECMO. Three days later, the patient developed secondary septic shock. The novel application of continuous CytoSorb TM treatment installed in the VA-ECMO circuit is demonstrated in this case during the management of simultaneous shocks. Advanced intensive care led to an improvement in the patient's condition, which facilitated successful weaning from mechanical ventilation. However, the patient died from a new onset fulminant septic shock two months after his initial cardiac surgery. VA-ECMO is suitable for installation of the CytoSorb TM cartridge. This modality could be an option for high-volume, continuous cytokine haemoadsorption when VA-ECMO is employed without renal replacement therapy. This specific application of CytoSorb TM was safe, feasible and contributed to the optimal management of simultaneous shocks.

  2. Freak Waves In The Ocean A~é­ We Need Continuous Measurements!

    NASA Astrophysics Data System (ADS)

    Liu, P.; Teng, C.; Mori, N.

    Freak waves, sometimes also known as rogue waves, are a particular kind of ocean waves that displays a singular, unexpected, and unusually high wave profile with an extraordinarily large and steep trough or crest. The existence of freak waves has be- come widely accepted while it always poses severe hazard to the navy fleets, merchant marines, offshore structures, and virtually all oceanic ventures. Multitudes of seagoing vessels and mariners have encountered freak waves over the years, many had resulted in disasters. The emerging interest in freak waves and the quest to grasp an understand- ing of the phenomenon have inspired numerous theoretical conjectures in recent years. But the practical void of actual field observation on freak waves renders even the well- developed theories remain unverified. Furthermore, the present wave measurement systems, which have been in practice for the last 5 decades, are not at all designed to capture freak waves. We wish therefore to propose and petition to all oceanic scientist and engineers to consider undertaking an unprecedented but technologically feasible practice of making continuous and uninterrupted wave measurements. As freak waves can happen anywhere in the ocean and at anytime, the continuous and uninterrupted measurements at a fixed station would certainly be warranted to document the occur- rence of freak waves, if present, and thus lead to basic realizations of the underlying driving mechanisms.

  3. Increased central arterial stiffness and altered cerebrovascular haemodynamic properties in South Asian older adults.

    PubMed

    Brar, I; Robertson, A D; Hughson, R L

    2016-05-01

    South Asians (SA) suffer from a higher burden of heart disease and stroke compared with White Caucasians (CA). We hypothesized that increased arterial stiffness in older adults of SA origin would be associated with greater cerebrovascular pulsatile pressure and flow characteristics compared with CA older adults. Forty-four SA and CA older adults, free of known cardiovascular and cerebrovascular diseases, were assessed. Vascular ageing was characterized by brachial-ankle pulse wave velocity, carotid pulse pressure, compliance coefficient (CC) and intima-media thickness (IMT). Duplex ultrasonography of the internal carotid arteries estimated anterior cerebral blood flow (aCBF) and cerebrovascular resistance (aCVR), and transcranial Doppler ultrasound quantified middle cerebral artery blood flow velocity, resistive index (RI) and pulsatility index (PI). Fasting blood samples were collected to assess glycaemic status, lipid profile and C-reactive protein. SA had higher carotid pulse pressure and lower CC indicating stiffer arteries compared with CA. Multiple regression analyses revealed that ethnic differences in arterial stiffness were associated with glycated haemoglobin level in SA. Among SA, an inverse association was observed between carotid CC and aCVR. In turn, aCVR was associated with a steeper reduction in aCBF in SA than in CA. IMT was strongly associated with greater PI and RI (r>0.81, P<0.001) in SA, whereas a weaker relationship for PI (r=0.46, P=0.03) and no significant relationship for RI were found in CA. The study found stronger associations between pulsatile cerebrovascular haemodynamics and structural and functional alterations in central arteries in SA that may underlie the elevated risk for cerebrovascular disease.

  4. The reduction of central sleep apnoea severity in the left lateral position is not due to an improvement in cardiac haemodynamics in patients with chronic heart failure.

    PubMed

    Traversi, Egidio; Rossi, Davide; Maestri, Roberto; Olmetti, Francesca; La Rovere, Maria Teresa; Pinna, Gian Domenico

    2017-06-01

    The severity of central sleep apnoea (CSA), a common comorbidity in patients with chronic heart failure (CHF) and reduced ejection fraction, markedly decreases from the supine to the lateral sleeping position, with no difference between the left and right positions. The mechanisms responsible for this beneficial effect have not yet been elucidated. We tested the hypothesis that CSA attenuation in the left lateral position is due, at least in part, to an improvement in cardiac haemodynamics. Sixteen CHF patients (male, aged 60 ± 7 years, New York Heart Association class 2.6 ± 0.5, left ventricular ejection fraction [LVEF] 30% ± 5%) with moderate-to-severe CSA underwent two consecutive tissue Doppler echocardiography examinations in random order, one in the left lateral position (90°) and the other in the supine position (0°). The following parameters were obtained: left ventricular end-diastolic volume (LVEDV) and LVEF, left atrial volume (LAV) and right atrial volume (RAV), mitral regurgitation (MR), cardiac output (CO), transmitral protodiastolic (E) wave deceleration time (DT), E/e' ratio, tricuspid annular plane systolic excursion (TAPSE), and right ventricular-atrial gradient (RVAG). The LAV, MR, E/e', RAV, and RVAG significantly increased, whereas the LVEF and TAPSE significantly decreased in the left lateral position. All changes, however, were of negligible clinical significance. No significant changes were observed in CO, DT, and LVEDV. This study shows that the reduction of CSA severity from the supine to the left lateral position in patients with CHF is not due to an improvement in cardiac haemodynamics. Other, noncardiac factors are likely to represent the main cause. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Continuous methane measurements from a late Holocene Greenland ice core: Atmospheric and in-situ signals

    NASA Astrophysics Data System (ADS)

    Rhodes, Rachael H.; Faïn, Xavier; Stowasser, Christopher; Blunier, Thomas; Chappellaz, Jérôme; McConnell, Joseph R.; Romanini, Daniele; Mitchell, Logan E.; Brook, Edward J.

    2013-04-01

    Ancient air trapped inside bubbles in ice cores can now be analysed for methane concentration utilising a laser spectrometer coupled to a continuous melter system. We present a new ultra-high resolution record of atmospheric methane variability over the last 1800 yr obtained from continuous analysis of a shallow ice core from the North Greenland Eemian project (NEEM-2011-S1) during a 4-week laboratory-based measurement campaign. Our record faithfully replicates the form and amplitudes of multi-decadal oscillations previously observed in other ice cores and demonstrates the detailed depth resolution (5.3 cm), rapid acquisition time (30 m day-1) and good long-term reproducibility (2.6%, 2σ) of the continuous measurement technique. In addition, we report the detection of high frequency ice core methane signals of non-atmospheric origin. Firstly, measurements of air from the firn-ice transition region and an interval of ice core dating from 1546-1560 AD (gas age) resolve apparently quasi-annual scale methane oscillations. Traditional gas chromatography measurements on discrete ice samples confirm these signals and indicate peak-to-peak amplitudes of ca. 22 parts per billion (ppb). We hypothesise that these oscillations result from staggered bubble close-off between seasonal layers of contrasting density during time periods of sustained multi-year atmospheric methane change. Secondly, we report the detection of abrupt (20-100 cm depth interval), high amplitude (35-80 ppb excess) methane spikes in the NEEM ice that are reproduced by discrete measurements. We show for the first time that methane spikes present in thin and infrequent layers in polar, glacial ice are accompanied by elevated concentrations of carbon- and nitrogen-based chemical impurities, and suggest that biological in-situ production may be responsible.

  6. Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for Column CO2 Measurements

    NASA Astrophysics Data System (ADS)

    Campbell, J. F.; Lin, B.; Obland, M. D.; Liu, Z.; Kooi, S. A.; Fan, T. F.; Nehrir, A. R.; Meadows, B.; Browell, E. V.

    2016-12-01

    Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for Column CO2 MeasurementsJoel F. Campbell1, Bing Lin1, Michael D. Obland1, Zhaoyan Liu1, Susan Kooi2, Tai-Fang Fan2, Amin R. Nehrir1, Byron Meadows1, Edward V. Browell31NASA Langley Research Center, Hampton, VA 23681 2SSAI, NASA Langley Research Center, Hampton, VA 23681 3STARSS-II Affiliate, NASA Langley Research Center, Hampton, VA 23681 AbstractGlobal and regional atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission and the Atmospheric Carbon and Transport (ACT) - America project are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity-Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space and airborne platforms to meet the ASCENDS and ACT-America science measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud returns. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby minimizing bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new sub-meter hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. These techniques are used in a new data processing

  7. Evaluation Models for Continuing Education Program Efficacy: How Does Athletic Training Continuing Education Measure up?

    ERIC Educational Resources Information Center

    Doherty-Restrepo, Jennifer L.; Hughes, Brian J.; Del Rossi, Gianluca; Pitney, William A.

    2009-01-01

    Objective: Although continuing education is required for athletic trainers (AT) to maintain their Board of Certification credential, little is known regarding its efficacy for advancing knowledge and improving patient care. Continuing professional education (CPE) is designed to provide professionals with important practical learning opportunities.…

  8. Accuracy of noninvasive and continuous hemoglobin measurement by pulse co-oximetry during preoperative phlebotomy.

    PubMed

    Dewhirst, Elisabeth; Naguib, Aymen; Winch, Peter; Rice, Julie; Galantowicz, Mark; McConnell, Patrick; Tobias, Joseph D

    2014-01-01

    In recent years, the continuous noninvasive hemoglobin measurement has been offered by devices using advanced pulse oximetry technology. Accuracy has been established in healthy adults as well as in surgical and intensive care unit patients but not in the setting of acute hemorrhage. In this study, we evaluated the accuracy of such a device in the clinical setting of preoperative phlebotomy thereby mimicking a scenario of acute blood loss. This prospective study included patients undergoing surgical repair of congenital heart disease (CHD) for whom preoperative phlebotomy was planned. Blood was removed after the induction of anesthesia and prior to the start of the surgical procedure. Replacement with crystalloid was guided by hemodynamic variables and cerebral oxygenation measured by near-infrared spectroscopy. Hemoglobin was measured by bedside whole blood analysis (total hemoglobin [tHb]) before and after phlebotomy, and concurrent measurements from the pulse co-oximeter (noninvasive, continuous, or spot-check testing of total hemoglobin [SpHb]) were recorded. The study cohort included 45 patients ranging in age from 3 months to 50 years. Preoperative phlebotomy removed an average of 9.2 mL/kg of blood that was replaced with an average of 7.2 mL/kg of crystalloid. The pre- and postphlebotomy tHb values were 13.0 ± 1.9 and 12.4 ± 1.8 g/dL, respectively. The absolute difference between the tHb and SpHb (▵Hb) was 1.2 ± 0.1 g/dL. Bland-Altman analysis revealed a bias of 0.1 g/dL, a precision of 1.5 g/dL, and 95% limits of agreement of -2.8 to 3.1 g/dL. In 52.2% of the sample sets, the SpHb was within 1 g/dL of the actual hemoglobin value (tHb), and in 80% of the sample sets, the SpHb was within 2 g/dL. No variation in the accuracy of the deviation was noted based on the patient's age, weight, or type of CHD (cyanotic versus acyanotic). The current study demonstrates that the accuracy of continuous, noninvasive hemoglobin measurement was not affected by acute

  9. The Reliability and Validity of Discrete and Continuous Measures of Psychopathology: A Quantitative Review

    ERIC Educational Resources Information Center

    Markon, Kristian E.; Chmielewski, Michael; Miller, Christopher J.

    2011-01-01

    In 2 meta-analyses involving 58 studies and 59,575 participants, we quantitatively summarized the relative reliability and validity of continuous (i.e., dimensional) and discrete (i.e., categorical) measures of psychopathology. Overall, results suggest an expected 15% increase in reliability and 37% increase in validity through adoption of a…

  10. Effects of long-term losartan and L-arginine treatment on haemodynamics, glomerular filtration, and SOD activity in spontaneously hypertensive rats.

    PubMed

    Miloradović, Zoran; Jovović, Durdica; Mihailović-Stanojević, Nevena; Milanović, Jelica Grujić; Milanović, Sladan

    2008-04-01

    Recently, it has been reported that losartan, an angiotensin II receptor (ATR) antagonist, depresses the angiotensin II-induced production of superoxide radicals. Also, in spontaneously hypertensive rats (SHR) endothelial dysfunction is associated with decreased nitric oxide (NO) synthesis. In this study, we examined the effects of long-term ATR blockade and L-arginine supplementation on the haemodynamic parameters, glomerular filtration, and oxidative status in SHR. Adult male SHR were treated with losartan (10 mg/kg) and with the NO donor L-arginine (2 g/kg) for 4 weeks. The animals were divided into the following experimental groups: control (n = 7), L-arginine (n = 7), losartan (n = 7), and L-arginine + losartan (n = 7). Mean arterial pressure (MAP), regional blood flow, urea clearance, and activity of superoxide dismutase (SOD) were measured at the end of treatment. MAP was significantly reduced in the losartan group compared with the control group (133.3 +/- 7.3 vs. 161.5 +/- 14.5 mm Hg). Aortic blood flow was significantly higher and aortic vascular resistance was significantly lower in all treated groups than in the control. Urea clearance rose significantly in the L-arginine + losartan group compared with control (393.27 +/- 37.58 vs. 218.68 +/- 42.03 microL x min(-1) x 100 g(-1)) as did the activity of SOD (1668.97 +/- 244.57 vs. 1083.18 +/- 169.96 U/g Hb). Our results suggest that the antihypertensive effect of losartan and L-arginine in SHR is not primarily mediated by increased SOD activity. Also, combined treatment with ATR blockade and L-arginine supplementation has a beneficial effect on renal function that is, at least in part, mediated by increased SOD activity in SHR.

  11. Intercomparison of active, passive and continuous instruments for radon and radon progeny measurements in the EML chamber and test facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George, A.C.; Knutson, E.O.; Tu, K.W.

    1995-12-01

    The results from the May 1995 Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurement conducted in the EML radon exposure and test facility are presented. Represented were 13 participants that measure radon with open faced and diffusion barrier activated carbon collectors, 10 with nuclear alpha track detectors, 9 with short-term and long-term electret/ionization chambers, and 13 with active and passive commercial electronic continuous monitors. For radon progeny, there were four participants that came in person to take part in the grab sampling methodology for measuring individual radon progeny and the potential alpha energy concentration (PAEC).more » There were 11 participants with continuous and integrating commercial electronic instruments that are used for measuring the PAEC. The results indicate that all the tested instruments that measure radon fulfill their intended purpose. All instruments and methods used for grab sampling for radon progeny did very well. However, most of the continuous and integrating electronic instruments used for measuring the PAEC or working level appear to underestimate the potential risk from radon progeny when the concentration of particles onto which the radon progeny are attached is <5,000 cm{sup -3}.« less

  12. Continuous All-Sky Cloud Measurements: Cloud Fraction Analysis Based on a Newly Developed Instrument

    NASA Astrophysics Data System (ADS)

    Aebi, C.; Groebner, J.; Kaempfer, N.; Vuilleumier, L.

    2017-12-01

    Clouds play an important role in the climate system and are also a crucial parameter for the Earth's surface energy budget. Ground-based measurements of clouds provide data in a high temporal resolution in order to quantify its influence on radiation. The newly developed all-sky cloud camera at PMOD/WRC in Davos (Switzerland), the infrared cloud camera (IRCCAM), is a microbolometer sensitive in the 8 - 14 μm wavelength range. To get all-sky information the camera is located on top of a frame looking downward on a spherical gold-plated mirror. The IRCCAM has been measuring continuously (day and nighttime) with a time resolution of one minute in Davos since September 2015. To assess the performance of the IRCCAM, two different visible all-sky cameras (Mobotix Q24M and Schreder VIS-J1006), which can only operate during daytime, are installed in Davos. All three camera systems have different software for calculating fractional cloud coverage from images. Our study analyzes mainly the fractional cloud coverage of the IRCCAM and compares it with the fractional cloud coverage calculated from the two visible cameras. Preliminary results of the measurement accuracy of the IRCCAM compared to the visible camera indicate that 78 % of the data are within ± 1 octa and even 93 % within ± 2 octas. An uncertainty of 1-2 octas corresponds to the measurement uncertainty of human observers. Therefore, the IRCCAM shows similar performance in detection of cloud coverage as the visible cameras and the human observers, with the advantage that continuous measurements with high temporal resolution are possible.

  13. Continuous 30-day measurements utilizing the monkey metabolism pod. [study of weightlessness effects

    NASA Technical Reports Server (NTRS)

    Pace, N.; Kodama, A. M.; Mains, R. C.; Rahlmann, D. F.; Grunbaum, B. W.

    1977-01-01

    A fiberglass system was previously described, using which quantitative physiological measurements could be made to study the effects of weightlessness on 10 to 14 kg adult monkeys maintained in comfortable restraint under space flight conditions. Recent improvements in the system have made it possible to obtain continuous measurements of respiratory gas exchange, cardiovascular function, and mineral balance for periods of up to 30 days on pig-tailed monkeys. It has also been possible to operate two pods which share one set of instrumentation, thereby permitting simultaneous measurements to be made on two animals by commutating signal outputs from the pods. In principle, more than two pods could be operated in this fashion. The system is compatible with Spacelab design. Representative physiological data from ground tests of the system are presented.

  14. Continuous flow measurements using fixed ultrasonic meters

    USGS Publications Warehouse

    Oltmann, Rick

    1993-01-01

    USGS has or soon will be installing four continuous flow-monitoring stations in the delta that will use ultrasonic velocity meters (DVM). Funding for the stations has been provided by USGS, DWR, USBR, and Contra Costa Water District.

  15. Coupling rotational and translational motion via a continuous measurement in an optomechanical sphere

    NASA Astrophysics Data System (ADS)

    Ralph, Jason F.; Jacobs, Kurt; Coleman, Jonathon

    2016-09-01

    We consider a measurement of the position of a spot painted on the surface of a trapped nano-optomechanical sphere. The measurement extracts information about the position of the spot and in doing so measures a combination of the orientation and position of the sphere. The quantum backaction of the measurement entangles and correlates these two degrees of freedom. Such a measurement is not available for atoms or ions and provides a mechanism to probe the quantum mechanical properties of trapped optomechanical spheres. In performing simulations of this measurement process we also test a numerical method introduced recently by Rouchon and collaborators [H. Amini, M. Mirrahimi, and P. Rouchon, in Proceedings of the 50th IEEE Conference on Decision and Control (CDC, 2011), pp. 6242-6247; P. Rouchon and J. F. Ralph, Phys. Rev. A 91, 012118 (2015), 10.1103/PhysRevA.91.012118] for solving stochastic master equations. This method guarantees the positivity of the density matrix when the Lindblad operators for all simultaneous continuous measurements are mutually commuting. We show that it is both simpler and far more efficient than previous methods.

  16. The Continued Assessment of Self-Continuity and Identity

    ERIC Educational Resources Information Center

    Dunkel, Curtis S.; Minor, Leslie; Babineau, Maureen

    2010-01-01

    Studies have found that self-continuity is predictive of a substantial number of important outcome variables. However, a recent series of studies brings into question the traditional method of measuring self-continuity in favor of an alternative (B. M. Baird, K. Le, & R. E. Lucas, 2006). The present study represents a further comparison of…

  17. Effect of intravenous infusion of an alpha-adrenergic blocking agent on the haemodynamic changes in human masseter muscle induced by cold pressor stimulation.

    PubMed

    Maekawa, K; Kuboki, T; Miyawaki, T; Shimada, M; Yamashita, A; Clark, G T

    1999-04-01

    This study evaluated the effect of intravenous infusion of a non-selective alpha-adrenergic blocking agent on masseter muscle haemodynamics induced by 4 degrees C cold pressor stimulation (CPS) of the right foot and ankle, which reportedly evokes a rapidly increasing sympathetic nerve activity in human skeletal muscle. Nine healthy non-smoking males (mean age 23.7+/-2.1 year) with no history of chronic muscle pain or migraine participated. The haemoglobin (Hb) concentration in the right masseter was continuously recorded by non-invasive, near-infrared spectroscopy. Heart rate and blood pressure were also recorded. The experiment involved the following sequence: (1) a placebo (physiological saline) with a CPS trial; (2) a 30-sec maximal voluntary clenching (MVC)-only trial; and (3) an alpha-adrenergic blocking agent with a CPS trial. The saline and drug trials each involved continuous recording for 1 min before, 2 min during and 5 min after the CPS. Physiological saline (20 ml) or phentolamine mesylate (20 ml) were infused at the rate of 2 ml/min. This infusion was begun 15 min before baseline recording and participants were not aware which solution (saline or phentolamine) was being infused. For the MVC trial, each participant performed a 30-sec MVC of his jaw-closing muscles followed by a 15-min rest between each trial. The individual Hb data were adjusted so that the baseline at the beginning of the experiment was equal to zero and all data were normalized as a percentage of the individual's highest absolute Hb change seen after the MVC. The mean baseline Hb concentrations 1 min before CPS were significantly higher in the alpha-blocker trial (83.6%) than in the placebo saline trial (P < 0.001). The change in mean Hb concentration from baseline during CPS in the alpha-blocker trial was significantly less than in the placebo trial (P = 0.006). Mean heart rate before CPS was also significantly higher in the alpha-blocker trial (85.2 beats/min) than in the placebo

  18. Detection and reconstruction of solidification cracks - Laser ultrasonic measurements during the continuous casting process of aluminum

    NASA Astrophysics Data System (ADS)

    Mitter, Thomas; Grün, Hubert; Roither, Jürgen; Betz, Andreas; Bozorgi, Salar; Reitinger, Bernhard; Burgholzer, Peter

    2014-05-01

    In the continuous casting process the avoidance and rapid detection of occurring solidification cracks in the slab is a crucial issue, in particular for the maintenance of a high quality level in further production processes. Due to the elevated temperatures of the slab surface a remote sensing non-destructive tool for quality inspection is required, which is also applicable for the harsh industrial environment. In this work the application of laser ultrasound (LUS) technique during the continuous casting process in industrial environment is shown. The proof of principle of the detection of the centered solidification cracks is shown by pulse-echo measurements with laser ultrasonic equipment for inline quality inspection. Preliminary examinations in the lab of different casted samples have shown the distinguishability of slabs with and without any solidification cracks. Furthermore the damping of the bulk wave has been used for the prediction of the dimension of the crack. With an adapted "synthetic aperture focusing technique" (SAFT) algorithm the image reconstruction of multiple measurements at different positions around the circumference has provided enough information for the estimation of the localization and extension of the centered solidification cracks. Subsequent first measurements using this laser ultrasonic setup during the continuous casting of aluminum were carried out and showed the proof of principle in an industrial environment with elevated temperatures, dust, cooling water and vibrations.

  19. A video-angiometer for simultaneous and continuous measurement of inner and outer vessel diameters. Technical report.

    PubMed

    Assmann, R; Henrich, H

    1978-09-29

    A system is described for continuously measuring vessel diameters. It bases on the evaluation of video signal differences of a video camera which are induced by light intensity differences (grey levels) caused by the vascular wall structures. The system is electronically linear, automatically measuring and in addition eyeball controlled by the human sensor: the inaccuracy does not exceed the 5% level.

  20. Modeling and Measurements of Multiphase Flow and Bubble Entrapment in Steel Continuous Casting

    NASA Astrophysics Data System (ADS)

    Jin, Kai; Thomas, Brian G.; Ruan, Xiaoming

    2016-02-01

    In steel continuous casting, argon gas is usually injected to prevent clogging, but the bubbles also affect the flow pattern, and may become entrapped to form defects in the final product. To investigate this behavior, plant measurements were conducted, and a computational model was applied to simulate turbulent flow of the molten steel and the transport and capture of argon gas bubbles into the solidifying shell in a continuous slab caster. First, the flow field was solved with an Eulerian k- ɛ model of the steel, which was two-way coupled with a Lagrangian model of the large bubbles using a discrete random walk method to simulate their turbulent dispersion. The flow predicted on the top surface agreed well with nailboard measurements and indicated strong cross flow caused by biased flow of Ar gas due to the slide-gate orientation. Then, the trajectories and capture of over two million bubbles (25 μm to 5 mm diameter range) were simulated using two different capture criteria (simple and advanced). Results with the advanced capture criterion agreed well with measurements of the number, locations, and sizes of captured bubbles, especially for larger bubbles. The relative capture fraction of 0.3 pct was close to the measured 0.4 pct for 1 mm bubbles and occurred mainly near the top surface. About 85 pct of smaller bubbles were captured, mostly deeper down in the caster. Due to the biased flow, more bubbles were captured on the inner radius, especially near the nozzle. On the outer radius, more bubbles were captured near to narrow face. The model presented here is an efficient tool to study the capture of bubbles and inclusion particles in solidification processes.

  1. Acute oxygenation changes on ischemic foot of a novel intermittent pneumatic compression device and of an existing sequential device in severe peripheral arterial disease

    PubMed Central

    2014-01-01

    Background Intermittent pneumatic compression (IPC) improves haemodynamics in peripheral arterial disease (PAD), but its effects on foot perfusion were scarcely studied. In severe PAD patients we measured the foot oxygenation changes evoked by a novel intermittent IPC device (GP), haemodynamics and compliance to the treatment. Reference values were obtained by a sequential foot-calf device (SFC). Methods Twenty ischemic limbs (Ankle-Brachial Index = 0.5 ± 0.2) of 12 PAD patients (7 male, age: 74.5 ± 10.8 y) with an interval of 48 ± 2 hours received a 35 minute treatment in supine position with two IPC devices: i) a Gradient Pump (GP), which slowly inflates a single thigh special sleeve and ii) an SFC (ArtAssist®, ACI Medical, San Marcos, CA, USA), which rapidly inflates two foot-calf sleeves. Main outcome measure: changes of oxygenated haemoglobin at foot (HbO2foot) by continuous near-infrared spectroscopy recording and quantified as area-under-curve (AUC) for periods of 5 minutes. Other measures: haemodynamics by echo-colour Doppler (time average velocity (TAV) and blood flow (BF) in the popliteal artery and in the femoral vein), patient compliance by a properly developed form. Results All patients completed the treatment with GP, 9 with SFC. HbO2foot during the working phase, considered as average value of the 5 minutes periods, increased with GP (AUC 458 ± 600 to 1216 ± 280) and decreased with SFC (AUC 231 ± 946 to −1088 ± 346), significantly for most periods (P < 0.05). The GP treatment was associated to significant haemodynamic changes from baseline to end of the treatment (TAV = 10.2 ± 3.3 to 13.5 ± 5.5 cm/sec, P = 0.004; BF = 452.0 ± 187.2 to 607.9 ± 237.8 ml/sec, P = 0.0001), not observed with SFC (TAV = 11.2 ± 3.4 to 11.8 ± 4.3 cm/sec; BF = 513.8 ± 203.7 to 505.9 ± 166.5 ml/min, P = n.s.). GP obtained a higher score of patient

  2. Universal Quantum Computing with Measurement-Induced Continuous-Variable Gate Sequence in a Loop-Based Architecture

    NASA Astrophysics Data System (ADS)

    Takeda, Shuntaro; Furusawa, Akira

    2017-09-01

    We propose a scalable scheme for optical quantum computing using measurement-induced continuous-variable quantum gates in a loop-based architecture. Here, time-bin-encoded quantum information in a single spatial mode is deterministically processed in a nested loop by an electrically programmable gate sequence. This architecture can process any input state and an arbitrary number of modes with almost minimum resources, and offers a universal gate set for both qubits and continuous variables. Furthermore, quantum computing can be performed fault tolerantly by a known scheme for encoding a qubit in an infinite-dimensional Hilbert space of a single light mode.

  3. Universal Quantum Computing with Measurement-Induced Continuous-Variable Gate Sequence in a Loop-Based Architecture.

    PubMed

    Takeda, Shuntaro; Furusawa, Akira

    2017-09-22

    We propose a scalable scheme for optical quantum computing using measurement-induced continuous-variable quantum gates in a loop-based architecture. Here, time-bin-encoded quantum information in a single spatial mode is deterministically processed in a nested loop by an electrically programmable gate sequence. This architecture can process any input state and an arbitrary number of modes with almost minimum resources, and offers a universal gate set for both qubits and continuous variables. Furthermore, quantum computing can be performed fault tolerantly by a known scheme for encoding a qubit in an infinite-dimensional Hilbert space of a single light mode.

  4. High-resolution continuous-flow analysis setup for water isotopic measurement from ice cores using laser spectroscopy

    NASA Astrophysics Data System (ADS)

    Emanuelsson, B. D.; Baisden, W. T.; Bertler, N. A. N.; Keller, E. D.; Gkinis, V.

    2015-07-01

    Here we present an experimental setup for water stable isotope (δ18O and δD) continuous-flow measurements and provide metrics defining the performance of the setup during a major ice core measurement campaign (Roosevelt Island Climate Evolution; RICE). We also use the metrics to compare alternate systems. Our setup is the first continuous-flow laser spectroscopy system that is using off-axis integrated cavity output spectroscopy (OA-ICOS; analyzer manufactured by Los Gatos Research, LGR) in combination with an evaporation unit to continuously analyze water samples from an ice core. A Water Vapor Isotope Standard Source (WVISS) calibration unit, manufactured by LGR, was modified to (1) enable measurements on several water standards, (2) increase the temporal resolution by reducing the response time and (3) reduce the influence from memory effects. While this setup was designed for the continuous-flow analysis (CFA) of ice cores, it can also continuously analyze other liquid or vapor sources. The custom setups provide a shorter response time (~ 54 and 18 s for 2013 and 2014 setup, respectively) compared to the original WVISS unit (~ 62 s), which is an improvement in measurement resolution. Another improvement compared to the original WVISS is that the custom setups have a reduced memory effect. Stability tests comparing the custom and WVISS setups were performed and Allan deviations (σAllan) were calculated to determine precision at different averaging times. For the custom 2013 setup the precision after integration times of 103 s is 0.060 and 0.070 ‰ for δ18O and δD, respectively. The corresponding σAllan values for the custom 2014 setup are 0.030, 0.060 and 0.043 ‰ for δ18O, δD and δ17O, respectively. For the WVISS setup the precision is 0.035, 0.070 and 0.042 ‰ after 103 s for δ18O, δD and δ17O, respectively. Both the custom setups and WVISS setup are influenced by instrumental drift with δ18O being more drift sensitive than δD. The

  5. Use of continuous glucose monitoring as an outcome measure in clinical trials.

    PubMed

    Beck, Roy W; Calhoun, Peter; Kollman, Craig

    2012-10-01

    Although developed to be a management tool for individuals with diabetes, continuous glucose monitoring (CGM) also has potential value for the assessment of outcomes in clinical studies. We evaluated using CGM as such an outcome measure. Data were analyzed from six previously completed inpatient studies in which both CGM (Freestyle Navigator™ [Abbott Diabetes Care, Alameda, CA] or Guardian(®) [Medtronic, Northridge, CA]) and reference glucose measurements were available. The analyses included 97 days of data from 93 participants with type 1 diabetes (age range, 5-57 years; mean, 18 ± 12 years). Mean glucose levels per day were similar for the CGM and reference measurements (median, 148 mg/dL vs. 143 mg/dL, respectively; P = 0.92), and the correlation of the two was high (r = 0.89). Similarly, most glycemia metrics showed no significant differences comparing CGM and reference values, except that the nadir glucose tended to be slightly lower and peak glucose slightly higher with reference measurements than CGM measurements (respective median, 59 mg/dL vs. 66 mg/dL [P = 0.05] and 262 mg/dL vs. 257 mg/dL [P = 0.003]) and glucose variability as measured with the coefficient of variation was slightly lower with CGM than reference measurements (respective median, 31% vs. 35%; P<0.001). A reasonably high degree of concordance exists when comparing outcomes based on CGM measurements with outcomes based on reference blood glucose measurements. CGM inaccuracy and underestimation of the extremes of hyperglycemia and hypoglycemia can be accounted for in a clinical trial's study design. Thus, in appropriate settings, CGM can be a very meaningful and feasible outcome measure for clinical trials.

  6. Combining the ASA Physical Classification System and Continuous Intraoperative Surgical Apgar Score Measurement in Predicting Postoperative Risk.

    PubMed

    Jering, Monika Zdenka; Marolen, Khensani N; Shotwell, Matthew S; Denton, Jason N; Sandberg, Warren S; Ehrenfeld, Jesse Menachem

    2015-11-01

    The surgical Apgar score predicts major 30-day postoperative complications using data assessed at the end of surgery. We hypothesized that evaluating the surgical Apgar score continuously during surgery may identify patients at high risk for postoperative complications. We retrospectively identified general, vascular, and general oncology patients at Vanderbilt University Medical Center. Logistic regression methods were used to construct a series of predictive models in order to continuously estimate the risk of major postoperative complications, and to alert care providers during surgery should the risk exceed a given threshold. Area under the receiver operating characteristic curve (AUROC) was used to evaluate the discriminative ability of a model utilizing a continuously measured surgical Apgar score relative to models that use only preoperative clinical factors or continuously monitored individual constituents of the surgical Apgar score (i.e. heart rate, blood pressure, and blood loss). AUROC estimates were validated internally using a bootstrap method. 4,728 patients were included. Combining the ASA PS classification with continuously measured surgical Apgar score demonstrated improved discriminative ability (AUROC 0.80) in the pooled cohort compared to ASA (0.73) and the surgical Apgar score alone (0.74). To optimize the tradeoff between inadequate and excessive alerting with future real-time notifications, we recommend a threshold probability of 0.24. Continuous assessment of the surgical Apgar score is predictive for major postoperative complications. In the future, real-time notifications might allow for detection and mitigation of changes in a patient's accumulating risk of complications during a surgical procedure.

  7. The effects of sildenafil citrate on feto-placental development and haemodynamics in a rabbit model of intrauterine growth restriction.

    PubMed

    López-Tello, Jorge; Arias-Álvarez, María; Jiménez-Martínez, Maria-Ángeles; Barbero-Fernández, Alicia; García-García, Rosa María; Rodríguez, María; Lorenzo, Pedro L; Torres-Rovira, Laura; Astiz, Susana; González-Bulnes, Antonio; Rebollar, Pilar G

    2017-06-01

    The present study evaluated the effectiveness of sildenafil citrate (SC) to improve placental and fetal growth in a diet-induced rabbit model of intrauterine growth restriction (IUGR). Pregnant rabbits were fed either ad libitum (Group C) or restricted to 50% of dietary requirements (Group R) or restricted and treated with SC (Group SC). The treatment with SC improved placental development by increasing vascularity and vessel hypertrophy in the decidua. The assessment of feto-placental haemodynamics showed higher resistance and pulsatility indices at the middle cerebral artery (MCA) in fetuses treated with SC when compared with Group R, which had increased systolic peak and time-averaged mean velocities at the MCA. Furthermore, fetuses in the SC group had significantly higher biparietal and thoracic diameters and longer crown-rump lengths than fetuses in Group R. Hence, the SC group had a reduced IUGR rate and a higher kit size at birth compared with Group R. In conclusion, SC may provide potential benefits in pregnancies with placental insufficiency and IUGR, partially counteracting the negative effects of food restriction on placental development and fetal growth. However, the present study also found evidence of a possible blood overflow in the brain that warrants further investigation.

  8. A Process Evaluation of Project Developmental Continuity. Interim Report II, Part B: Recommendations for Measuring Program Impact.

    ERIC Educational Resources Information Center

    Love, John M.; And Others

    This report presents recommendations for measures to be used in assessing the impact of Project Developmental Continuity (PDC). Chapter I reviews the purpose of the impact study and presents the basic considerations guiding the selection of measures. Chapter II describes the review process that led to the final recommendations. Chapter III…

  9. Continuous Sound Velocity Measurements along the Shock Hugoniot Curve of Quartz

    NASA Astrophysics Data System (ADS)

    Li, Mu; Zhang, Shuai; Zhang, Hongping; Zhang, Gongmu; Wang, Feng; Zhao, Jianheng; Sun, Chengwei; Jeanloz, Raymond

    2018-05-01

    We report continuous measurements of the sound velocity along the principal Hugoniot curve of α quartz between 0.25 and 1.45 TPa, as determined from lateral release waves intersecting the shock front as a function of time in decaying-shock experiments. The measured sound velocities are lower than predicted by prior models, based on the properties of stishovite at densities below ˜7 g /cm3 , but agree with density functional theory molecular dynamics calculations and an empirical wide-regime equation of state presented here. The Grüneisen parameter calculated from the sound velocity decreases from γ ˜1 .3 at 0.25 TPa to 0.66 at 1.45 TPa. In combination with evidence for increased (configurational) specific heat and decreased bulk modulus, the values of γ suggest a high thermal expansion coefficient at ˜0. 25 - 0 .65 TPa , where SiO2 is thought to be a bonded liquid. From our measurements, dissociation of the molecular bonds persists to ˜0. 65 - 1 .0 TPa , consistent with estimates by other methods. At higher densities, the sound velocity is close to predictions from previous models, and the Grüneisen parameter approaches the ideal gas value.

  10. Haemodynamic Performance of Low Strength Below Knee Graduated Elastic Compression Stockings in Health, Venous Disease, and Lymphoedema.

    PubMed

    Lattimer, C R; Kalodiki, E; Azzam, M; Geroulakos, G

    2016-07-01

    To test the in vivo haemodynamic performance of graduated elastic compression (GEC) stockings using air-plethysmography (APG) in healthy volunteers (controls) and patients with varicose veins (VVs), post-thrombotic syndrome (PTS), or lymphoedema. Responsiveness data were used to determine which group benefited the most from GEC. There were 12 patients per group compared using no compression, knee-length Class 1 (18-21 mmHg) compression, and Class 2 (23-32 mmHg) compression. Stocking/leg interface pressures (mmHg) were measured supine in two places using an air-sensor transducer. Stocking performance parameters, investigated before and after GEC, included the standard APG tests (working venous volume [wVV], venous filling index [VFI], venous drainage index [VDI], ejection fraction [EF]) and the occlusion plethysmography tests (incremental pressure causing the maximal increase in calf volume [IPMIV], outflow fraction [OF]). Results were expressed as median and interquartile range. Significant graduated compression was achieved in all four groups with higher interface pressures at the ankle. Only the VVs patients had a significant reduction in their wVV (without: 133 [109-146] vs. class1: 93 [74-113] mL) and the VFI (without: 4.6 [3-7.1] vs. class1: 3.1 [1.9-5] mL/s), both at p <.05. The IPMIV improved significantly in all groups except in the PTS group (p <.05). The OF improved only in the controls (without: 43 [38-51] vs. class1: 50 [48-53] %) and the VVs patients (without: 47 [39-58] vs. class1: 56 [50-64] %), both at p <.05. There were no significant differences in the VDI or the EF with GEC. Compression dose-response relationships were not observed. Patients with varicose veins improved the most, whereas those with PTS improved the least. Performance seemed to depend more on disease pathophysiology than compression strength. However, the lack of responsiveness to compression strength may be related to the low external pressures used. Stocking performance tests

  11. High-resolution continuous flow analysis setup for water isotopic measurement from ice cores using laser spectroscopy

    NASA Astrophysics Data System (ADS)

    Emanuelsson, B. D.; Baisden, W. T.; Bertler, N. A. N.; Keller, E. D.; Gkinis, V.

    2014-12-01

    Here we present an experimental setup for water stable isotopes (δ18O and δD) continuous flow measurements. It is the first continuous flow laser spectroscopy system that is using Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS; analyzer manufactured by Los Gatos Research - LGR) in combination with an evaporation unit to continuously analyze sample from an ice core. A Water Vapor Isotopic Standard Source (WVISS) calibration unit, manufactured by LGR, was modified to: (1) increase the temporal resolution by reducing the response time (2) enable measurements on several water standards, and (3) to reduce the influence from memory effects. While this setup was designed for the Continuous Flow Analysis (CFA) of ice cores, it can also continuously analyze other liquid or vapor sources. The modified setup provides a shorter response time (~54 and 18 s for 2013 and 2014 setup, respectively) compared to the original WVISS unit (~62 s), which is an improvement in measurement resolution. Another improvement compared to the original WVISS is that the modified setup has a reduced memory effect. Stability tests comparing the modified WVISS and WVISS setups were performed and Allan deviations (σAllan) were calculated to determine precision at different averaging times. For the 2013 modified setup the precision after integration times of 103 s are 0.060 and 0.070‰ for δ18O and δD, respectively. For the WVISS setup the corresponding σAllan values are 0.030, 0.060 and 0.043‰ for δ18O, δD and δ17O, respectively. For the WVISS setup the precision is 0.035, 0.070 and 0.042‰ after 103 s for δ18O, δD and δ17O, respectively. Both the modified setups and WVISS setup are influenced by instrumental drift with δ18O being more drift sensitive than δD. The σAllan values for δ18O of 0.30 and 0.18‰ for the modified (2013) and WVISS setup, respectively after averaging times of 104 s (2.78 h). The Isotopic Water Analyzer (IWA)-modified WVISS setup used during the

  12. Adaptive single-pixel imaging with aggregated sampling and continuous differential measurements

    NASA Astrophysics Data System (ADS)

    Huo, Yaoran; He, Hongjie; Chen, Fan; Tai, Heng-Ming

    2018-06-01

    This paper proposes an adaptive compressive imaging technique with one single-pixel detector and single arm. The aggregated sampling (AS) method enables the reduction of resolutions of the reconstructed images. It aims to reduce the time and space consumption. The target image with a resolution up to 1024 × 1024 can be reconstructed successfully at the 20% sampling rate. The continuous differential measurement (CDM) method combined with a ratio factor of significant coefficient (RFSC) improves the imaging quality. Moreover, RFSC reduces the human intervention in parameter setting. This technique enhances the practicability of single-pixel imaging with the benefits from less time and space consumption, better imaging quality and less human intervention.

  13. Wearable motion sensors to continuously measure real-world physical activities.

    PubMed

    Dobkin, Bruce H

    2013-12-01

    Rehabilitation for sensorimotor impairments aims to improve daily activities, walking, exercise, and motor skills. Monitoring of practice and measuring outcomes, however, is usually restricted to laboratory-based procedures and self-reports. Mobile health devices may reverse these confounders of daily care and research trials. Wearable, wireless motion sensor data, analyzed by activity pattern-recognition algorithms, can describe the type, quantity, and quality of mobility-related activities in the community. Data transmission from the sensors to a cell phone and the Internet enable continuous monitoring. Remote access to laboratory quality data about walking speed, duration and distance, gait asymmetry and smoothness of movements, as well as cycling, exercise, and skills practice, opens new opportunities to engage patients in progressive, personalized therapies with feedback about the performance. Clinical trial designs will be able to include remote verification of the integrity of complex physical interventions and compliance with practice, as well as capture repeated, ecologically sound, ratio scale outcome measures. Given the progressively falling cost of miniaturized wearable gyroscopes, accelerometers, and other physiologic sensors, as well as inexpensive data transmission, sensing systems may become as ubiquitous as cell phones for healthcare. Neurorehabilitation can develop these mobile health platforms for daily care and clinical trials to improve exercise and fitness, skills learning, and physical functioning.

  14. Enhanced method to reconstruct mode shapes of continuous scanning measurements using the Hilbert Huang transform and the modal analysis method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Jongsuh; Hussain, Syed Hassaan; Wang, Semyung, E-mail: smwang@gist.ac.kr

    2014-09-15

    Generally, it is time consuming to experimentally identify the operating deflection shape or mode shape of a structure. To overcome this problem, the Hilbert Huang transform (HHT) technique has been recently proposed. This technique is used to extract the mode shape from measurements that continuously measure the vibration of a region of interest within a structure using a non-contact laser sensor. In previous research regarding the HHT, two technical processes were needed to obtain the mode shape for each mode. The purpose of this study is to improve and complement our previous research, and for this purpose, a modal analysismore » approach is adapted without using the two technical processes to obtain an accurate un-damped impulse response of each mode for continuous scanning measurements. In addition, frequency response functions for each type of beam are derived, making it possible to make continuously scanned measurements along a straight profile. In this paper, the technical limitations and drawbacks of the damping compensation technique used in previous research are identified. In addition, the separation of resonant frequency (the Doppler effect) that occurs in continuous scanning measurements and the separation of damping phenomenon are also observed. The proposed method is quantitatively verified by comparing it with the results obtained from a conventional approach to estimate the mode shape with an impulse response.« less

  15. In Situ Stoichiometry in a Large River: Continuous Measurement of Doc, NO3 and PO4 in the Sacramento River

    NASA Astrophysics Data System (ADS)

    Downing, B. D.; Pellerin, B. A.; Bergamaschi, B. A.; Saraceno, J.

    2011-12-01

    Studying controls on geochemical processes in rivers and streams is difficult because concentration and composition often changes rapidly in response to physical and biological forcings. Understanding biogeochemical dynamics in rivers will improve current understanding of the role of watershed sources to carbon cycling, river and stream ecology, and loads to estuaries and oceans. Continuous measurements of dissolved organic carbon (DOC), nitrate (NO3-) and soluble reactive phosphate (SRP) concentrations are now possible, along with some information about DOC composition. In situ sensors designed to measure these constituents provide high frequency, real-time data that can elucidate hydrologic and biogeochemical controls which are difficult to detect using more traditional sampling approaches. Here we present a coupled approach, using in situ optical instrumentation with discharge measurements to provide quantitative estimates of constituent loads to investigate C, NO3- and SRP sources and processing in the Sacramento River, CA, USA. Continuous measurement of DOC concentration was conducted by use of a miniature in situ fluorometer (Turner Designs Cyclops) designed to measure chromophoric dissolved organic matter fluorescence (FDOM) over the course of an entire year. Nitrate was measured concurrently using a Satlantic SUNA and phosphate was measured using a WETLabs model Cycle-P instrument for a two week period in July 2011. Continuous measurement from these instruments paired with continuous measurement of physical water quality variables such as temperature, pH, specific conductance, dissolved oxygen, and turbidity, were used to investigate physical and chemical dynamics of DOC, NO3-, SRP over varying time scales. Deploying these instruments at pre-existing USGS discharge gages allowed for calculation of instantaneous and integrated constituent fluxes, as well as filling in gaps in our understanding biogeochemical processes and transport. Results from the study

  16. Use of Continuous Glucose Monitoring as an Outcome Measure in Clinical Trials

    PubMed Central

    Calhoun, Peter; Kollman, Craig

    2012-01-01

    Abstract Objective Although developed to be a management tool for individuals with diabetes, continuous glucose monitoring (CGM) also has potential value for the assessment of outcomes in clinical studies. We evaluated using CGM as such an outcome measure. Research Design and Methods Data were analyzed from six previously completed inpatient studies in which both CGM (Freestyle Navigator™ [Abbott Diabetes Care, Alameda, CA] or Guardian® [Medtronic, Northridge, CA]) and reference glucose measurements were available. The analyses included 97 days of data from 93 participants with type 1 diabetes (age range, 5–57 years; mean, 18±12 years). Results Mean glucose levels per day were similar for the CGM and reference measurements (median, 148 mg/dL vs. 143 mg/dL, respectively; P=0.92), and the correlation of the two was high (r=0.89). Similarly, most glycemia metrics showed no significant differences comparing CGM and reference values, except that the nadir glucose tended to be slightly lower and peak glucose slightly higher with reference measurements than CGM measurements (respective median, 59 mg/dL vs. 66 mg/dL [P=0.05] and 262 mg/dL vs. 257 mg/dL [P=0.003]) and glucose variability as measured with the coefficient of variation was slightly lower with CGM than reference measurements (respective median, 31% vs. 35%; P<0.001). Conclusions A reasonably high degree of concordance exists when comparing outcomes based on CGM measurements with outcomes based on reference blood glucose measurements. CGM inaccuracy and underestimation of the extremes of hyperglycemia and hypoglycemia can be accounted for in a clinical trial's study design. Thus, in appropriate settings, CGM can be a very meaningful and feasible outcome measure for clinical trials. PMID:23013201

  17. Toward predicting tensile strength of pharmaceutical tablets by ultrasound measurement in continuous manufacturing.

    PubMed

    Razavi, Sonia M; Callegari, Gerardo; Drazer, German; Cuitiño, Alberto M

    2016-06-30

    An ultrasound measurement system was employed as a non-destructive method to evaluate its reliability in predicting the tensile strength of tablets and investigate the benefits of incorporating it in a continuous line, manufacturing solid dosage forms. Tablets containing lactose, acetaminophen, and magnesium stearate were manufactured continuously and in batches. The effect of two processing parameters, compaction force and level of shear strain were examined. Young's modulus and tensile strength of tablets were obtained by ultrasound and diametrical mechanical testing, respectively. It was found that as the blend was exposed to increasing levels of shear strain, the speed of sound in the tablets decreased and the tablets became both softer and mechanically weaker. Moreover, the results indicate that two separate tablet material properties (e.g., relative density and Young's modulus) are necessary in order to predict tensile strength. A strategy for hardness prediction is proposed that uses the existing models for Young's modulus and tensile strength of porous materials. Ultrasound testing was found to be very sensitive in differentiating tablets with similar formulation but produced under different processing conditions (e.g., different level of shear strain), thus, providing a fast, and non-destructive method for hardness prediction that could be incorporated to a continuous manufacturing process. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. A porcine model for acute ischaemic right ventricular dysfunction.

    PubMed

    Haraldsen, Pernille; Lindstedt, Sandra; Metzsch, Carsten; Algotsson, Lars; Ingemansson, Richard

    2014-01-01

    To establish an experimental model for acute ischaemic isolated right ventricular dysfunction and the subsequent haemodynamic changes. An open-chest porcine model with ischaemic dysfunction of the right ventricle induced by ligation of the three main branches supporting the right ventricular free wall. Invasive monitoring of mean arterial blood pressure (MAP), central venous pressure (CVP), left atrial pressure (LAP) and right ventricular pressure (RVP); ultrasonic measurement of cardiac output (CO) and calculation of haemodynamic parameters such as stroke volume (SV), systemic vascular resistance (SVR), pulmonary vascular resistance (PVR) and right ventricular stroke work (RVSW) using standard formulae. The ischaemic challenge to the right ventricle resulted in a significant (≥30%) reduction in RVSW associated with an increase (6-25%) in CVP and reduction (8-18%) in pulmonary artery pressure (PAP) despite unchanged PVR, all reflecting the failing right ventricle. There was also a significant drop in CO (14-22%) despite unchanged LAP indicating lessened transpulmonary delivery of left ventricular preload due to the failing right ventricle causing the haemodynamic compromise rather than left ventricular failure. Supraventricular and ventricular arrhythmias occurred in three and two out of seven pigs, respectively-all of which except one were successfully resuscitated with cardioversion and/or defibrillation. This novel open-chest porcine model of induced ischaemia of the right ventricular free wall resulted in significant haemodynamic compromise confirmed using standard haemodynamic measurements making it useful for further research on acute, ischaemic isolated right ventricular failure.

  19. CONTINUOUS MEASUREMENT OF FINE AND ULTRAFINE PARTICULATE MATTER, CRITERIA POLLUTANTS AND METEOROLOGICAL CONDITIONS IN URBAN EL PASO, TEXAS

    EPA Science Inventory

    Continuous measurements of aerosol size distributions were made in El Paso, TX, for a period in winter 1999. Size distribution measurements were performed at two urban locations in El Paso using two pairs of the scanning mobility particle sizer and the aerodynamic particle si...

  20. Self-referenced continuous-variable measurement-device-independent quantum key distribution

    NASA Astrophysics Data System (ADS)

    Wang, Yijun; Wang, Xudong; Li, Jiawei; Huang, Duan; Zhang, Ling; Guo, Ying

    2018-05-01

    We propose a scheme to remove the demand of transmitting a high-brightness local oscillator (LO) in continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol, which we call as the self-referenced (SR) CV-MDI QKD. We show that our scheme is immune to the side-channel attacks, such as the calibration attacks, the wavelength attacks and the LO fluctuation attacks, which are all exploiting the security loopholes introduced by transmitting the LO. Besides, the proposed scheme waives the necessity of complex multiplexer and demultiplexer, which can greatly simplify the QKD processes and improve the transmission efficiency. The numerical simulations under collective attacks show that all the improvements brought about by our scheme are only at the expense of slight transmission distance shortening. This scheme shows an available method to mend the security loopholes incurred by transmitting LO in CV-MDI QKD.

  1. Continuing Medical Education Improves Gastroenterologists' Compliance with Inflammatory Bowel Disease Quality Measures.

    PubMed

    Sapir, Tamar; Moreo, Kathleen; Carter, Jeffrey D; Greene, Laurence; Patel, Barry; Higgins, Peter D R

    2016-07-01

    Low rates of compliance with quality measures for inflammatory bowel disease (IBD) have been reported for US gastroenterologists. We assessed the influence of quality improvement (QI) education on compliance with physician quality reporting system (PQRS) measures for IBD and measures related to National Quality Strategy (NQS) priorities. Forty community-based gastroenterologists participated in the QI study; 20 were assigned to educational intervention and control groups, respectively. At baseline, randomly selected charts of patients with moderate-to-severe ulcerative colitis were retrospectively reviewed for the gastroenterologists' performance of 8 PQRS IBD measures and 4 NQS-related measures. The intervention group participated in a series of accredited continuing medical education (CME) activities focusing on QI. Follow-up chart reviews were conducted 6 months after the CME activities. Independent t tests were conducted to compare between-group differences in baseline-to-follow-up rates of documented compliance with each measure. The analysis included 299 baseline charts and 300 follow-up charts. The intervention group had significantly greater magnitudes of improvement than the control group for the following measures: assessment of IBD type, location, and activity (+14 %, p = 0.009); influenza vaccination (+13 %, p = 0.025); pneumococcal vaccination (+20 %, p = 0.003); testing for latent tuberculosis before anti-TNF-α therapy (+10 %, p = 0.028); assessment of hepatitis B virus status before anti-TNF-α therapy (+9 %, p = 0.010); assessment of side effects (+17 %, p = 0.048), and counseling patients about cancer risks (+13 %, p = 0.013). QI-focused CME improves community-based gastroenterologists' compliance with IBD quality measures and measures aligned with NQS priorities.

  2. Semi-Continuous Measurements of Aerosol Chemical Composition During the Summer 2002 Yosemite National Park Special Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collette, J; Lee, T; Heath, J

    2003-02-16

    Semi-continuous measurements of fine particle composition were made over a period of several weeks in summer 2002 in Yosemite National Park, California. These included measurement of aerosol ionic composition (by PILS- Particle-Into-Liquid System) and aerosol carbon (by dual wavelength aethalometer and an R&P particulate carbon monitor). The data reveal that aerosol composition at the site is highly :variable in time, with a strong diurnal cycle. Interestingly, however, different diurnal cycles were sometimes observed for different chemical constituents of the particles. Organic carbon was observed to dominate fine particle mass, with some periods apparently associated with influx of smoke from wildfiresmore » in the western U.S. Measurements of fine particle carbon isotopes revealed the fraction of carbon from biogenic sources to range from approximately 73 to 95%. The ionic fraction of the aerosol was usually dominated by ammoniated sulfate. During most periods, PM{sub 2.5} nitrate was found primarily in sea salt particles from which chloride had been displaced. Strong variations in the extent of ammonia neutralization of sulfate were also observed. The ability to observe rapid changes in aerosol composition using these semi-continuous aerosol composition measurements is helpful for understanding the dynamic chemical composition of fine particles responsible for regional haze.« less

  3. Cardiorespiratory dynamics measured from continuous ECG monitoring improves detection of deterioration in acute care patients: A retrospective cohort study

    PubMed Central

    Clark, Matthew T.; Calland, James Forrest; Enfield, Kyle B.; Voss, John D.; Lake, Douglas E.; Moorman, J. Randall

    2017-01-01

    Background Charted vital signs and laboratory results represent intermittent samples of a patient’s dynamic physiologic state and have been used to calculate early warning scores to identify patients at risk of clinical deterioration. We hypothesized that the addition of cardiorespiratory dynamics measured from continuous electrocardiography (ECG) monitoring to intermittently sampled data improves the predictive validity of models trained to detect clinical deterioration prior to intensive care unit (ICU) transfer or unanticipated death. Methods and findings We analyzed 63 patient-years of ECG data from 8,105 acute care patient admissions at a tertiary care academic medical center. We developed models to predict deterioration resulting in ICU transfer or unanticipated death within the next 24 hours using either vital signs, laboratory results, or cardiorespiratory dynamics from continuous ECG monitoring and also evaluated models using all available data sources. We calculated the predictive validity (C-statistic), the net reclassification improvement, and the probability of achieving the difference in likelihood ratio χ2 for the additional degrees of freedom. The primary outcome occurred 755 times in 586 admissions (7%). We analyzed 395 clinical deteriorations with continuous ECG data in the 24 hours prior to an event. Using only continuous ECG measures resulted in a C-statistic of 0.65, similar to models using only laboratory results and vital signs (0.63 and 0.69 respectively). Addition of continuous ECG measures to models using conventional measurements improved the C-statistic by 0.01 and 0.07; a model integrating all data sources had a C-statistic of 0.73 with categorical net reclassification improvement of 0.09 for a change of 1 decile in risk. The difference in likelihood ratio χ2 between integrated models with and without cardiorespiratory dynamics was 2158 (p value: <0.001). Conclusions Cardiorespiratory dynamics from continuous ECG monitoring detect

  4. Cardiorespiratory dynamics measured from continuous ECG monitoring improves detection of deterioration in acute care patients: A retrospective cohort study.

    PubMed

    Moss, Travis J; Clark, Matthew T; Calland, James Forrest; Enfield, Kyle B; Voss, John D; Lake, Douglas E; Moorman, J Randall

    2017-01-01

    Charted vital signs and laboratory results represent intermittent samples of a patient's dynamic physiologic state and have been used to calculate early warning scores to identify patients at risk of clinical deterioration. We hypothesized that the addition of cardiorespiratory dynamics measured from continuous electrocardiography (ECG) monitoring to intermittently sampled data improves the predictive validity of models trained to detect clinical deterioration prior to intensive care unit (ICU) transfer or unanticipated death. We analyzed 63 patient-years of ECG data from 8,105 acute care patient admissions at a tertiary care academic medical center. We developed models to predict deterioration resulting in ICU transfer or unanticipated death within the next 24 hours using either vital signs, laboratory results, or cardiorespiratory dynamics from continuous ECG monitoring and also evaluated models using all available data sources. We calculated the predictive validity (C-statistic), the net reclassification improvement, and the probability of achieving the difference in likelihood ratio χ2 for the additional degrees of freedom. The primary outcome occurred 755 times in 586 admissions (7%). We analyzed 395 clinical deteriorations with continuous ECG data in the 24 hours prior to an event. Using only continuous ECG measures resulted in a C-statistic of 0.65, similar to models using only laboratory results and vital signs (0.63 and 0.69 respectively). Addition of continuous ECG measures to models using conventional measurements improved the C-statistic by 0.01 and 0.07; a model integrating all data sources had a C-statistic of 0.73 with categorical net reclassification improvement of 0.09 for a change of 1 decile in risk. The difference in likelihood ratio χ2 between integrated models with and without cardiorespiratory dynamics was 2158 (p value: <0.001). Cardiorespiratory dynamics from continuous ECG monitoring detect clinical deterioration in acute care patients

  5. Continuous-variable measurement-device-independent quantum key distribution with photon subtraction

    NASA Astrophysics Data System (ADS)

    Ma, Hong-Xin; Huang, Peng; Bai, Dong-Yun; Wang, Shi-Yu; Bao, Wan-Su; Zeng, Gui-Hua

    2018-04-01

    It has been found that non-Gaussian operations can be applied to increase and distill entanglement between Gaussian entangled states. We show the successful use of the non-Gaussian operation, in particular, photon subtraction operation, on the continuous-variable measurement-device-independent quantum key distribution (CV-MDI-QKD) protocol. The proposed method can be implemented based on existing technologies. Security analysis shows that the photon subtraction operation can remarkably increase the maximal transmission distance of the CV-MDI-QKD protocol, which precisely make up for the shortcoming of the original CV-MDI-QKD protocol, and one-photon subtraction operation has the best performance. Moreover, the proposed protocol provides a feasible method for the experimental implementation of the CV-MDI-QKD protocol.

  6. Continuous quality improvement for continuity of care.

    PubMed

    Kibbe, D C; Bentz, E; McLaughlin, C P

    1993-03-01

    Continuous quality improvement (CQI) techniques have been used most frequently in hospital operations such as pharmaceutical ordering, patient admitting, and billing of insurers, and less often to analyze and improve processes that are close to the clinical interaction of physicians and their patients. This paper describes a project in which CQI was implemented in a family practice setting to improve continuity of care. A CQI study team was assembled in response to patients' complaints about not being able to see their regular physician providers when they wanted. Following CQI methods, the performance of the practice in terms of provider continuity was measured. Two "customer" groups were surveyed: physician faculty members were surveyed to assess their attitudes about continuity, and patients were surveyed about their preferences for provider continuity and convenience factors. Process improvements were selected in the critical pathways that influence provider continuity. One year after implementation of selected process improvements, repeat chart audit showed that provider continuity levels had improved from .45 to .74, a 64% increase from 1 year earlier. The project's main accomplishment was to establish the practicality of using CQI methods in a primary care setting to identify a quality issue of value to both providers and patients, in this case, continuity of provider care, and to identify processes that linked the performance of health care delivery procedures with patient expectations.

  7. Retrieval of Aerosol Parameters from Continuous H24 Lidar-Ceilometer Measurements

    NASA Astrophysics Data System (ADS)

    Dionisi, D.; Barnaba, F.; Costabile, F.; Di Liberto, L.; Gobbi, G. P.; Wille, H.

    2016-06-01

    Ceilometer technology is increasingly applied to the monitoring and the characterization of tropospheric aerosols. In this work, a method to estimate some key aerosol parameters (extinction coefficient, surface area concentration and volume concentration) from ceilometer measurements is presented. A numerical model has been set up to derive a mean functional relationships between backscatter and the above mentioned parameters based on a large set of simulated aerosol optical properties. A good agreement was found between the modeled backscatter and extinction coefficients and the ones measured by the EARLINET Raman lidars. The developed methodology has then been applied to the measurements acquired by a prototype Polarization Lidar-Ceilometer (PLC). This PLC instrument was developed within the EC- LIFE+ project "DIAPASON" as an upgrade of the commercial, single-channel Jenoptik CHM15k system. The PLC run continuously (h24) close to Rome (Italy) for a whole year (2013-2014). Retrievals of the aerosol backscatter coefficient at 1064 nm and of the relevant aerosol properties were performed using the proposed methodology. This information, coupled to some key aerosol type identification made possible by the depolarization channel, allowed a year-round characterization of the aerosol field at this site. Examples are given to show how this technology coupled to appropriate data inversion methods is potentially useful in the operational monitoring of parameters of air quality and meteorological interest.

  8. Continuous measurements of flow rate in a shallow gravel-bed river by a new acoustic system

    NASA Astrophysics Data System (ADS)

    Kawanisi, K.; Razaz, M.; Ishikawa, K.; Yano, J.; Soltaniasl, M.

    2012-05-01

    The continuous measurement of river discharge for long periods of time is crucial in water resource studies. However, the accurate estimation of river discharge is a difficult and labor-intensive procedure; thus, a robust and efficient method of measurement is required. Continuous measurements of flowrate have been carried out in a wide, shallow gravel bed river (water depth ≈ 0.6 m under low-flow conditions, width ≈ 115 m) using Fluvial Acoustic Tomography System (FATS) that has 25 kHz broadband transducers with horizontally omnidirectional and vertically hemispherical beam patterns. Reciprocal sound transmissions were performed between the two acoustic stations located diagonally on both sides of the river. The horizontal distance between the transducers was 301.96 m. FATS enabled the measurement of the depth- and range-averaged sound speed and flow velocity along the ray path. In contrast to traditional point/transect measurements of discharge, in a fraction of a second, FATS covers the entire cross section of river in a single measurement. The flow rates measured by FATS were compared to those estimated by moving boat Acoustic Doppler Current Profiler (ADCP) and rating curve (RC) methods. FATS estimates were in good agreement with ADCP estimates over a range of 20 to 65 m3 s-1. The RMS of residual between the two measurements was 2.41 m3 s-1. On the other hand the flowrate by RC method fairly agreed with FATS estimates for greater discharges than around 40 m3 s-1. This inconsistency arises from biased RC estimates in low flows. Thus, the flow rates derived from FATS could be considered reliable.

  9. Pregnancy-specific stress, fetoplacental haemodynamics, and neonatal outcomes in women with small for gestational age pregnancies: a secondary analysis of the multicentre Prospective Observational Trial to Optimise Paediatric Health in Intrauterine Growth Restriction

    PubMed Central

    Levine, Terri A; Grunau, Ruth E; Segurado, Ricardo; Daly, Sean; Geary, Michael P; Kennelly, Mairead M; O’Donoghue, Keelin; Hunter, Alyson; Morrison, John J; Burke, Gerard; Dicker, Patrick; Tully, Elizabeth C; Malone, Fergal D; Alderdice, Fiona A; McAuliffe, Fionnuala M

    2017-01-01

    Objectives To examine associations between maternal pregnancy-specific stress and umbilical (UA PI) and middle cerebral artery pulsatility indices (MCA PI), cerebroplacental ratio, absent end diastolic flow (AEDF), birthweight, prematurity, neonatal intensive care unit admission and adverse obstetric outcomes in women with small for gestational age pregnancies. It was hypothesised that maternal pregnancy-specific stress would be associated with fetoplacental haemodynamics and neonatal outcomes. Design This is a secondary analysis of data collected for a large-scale prospective observational study. Setting This study was conducted in the seven major obstetric hospitals in Ireland and Northern Ireland. Participants Participants included 331 women who participated in the Prospective Observational Trial to Optimise Paediatric Health in Intrauterine Growth Restriction. Women with singleton pregnancies between 24 and 36 weeks gestation, estimated fetal weight <10th percentile and no major structural or chromosomal abnormalities were included. Primary and secondary outcome measures Serial Doppler ultrasound examinations of the umbilical and middle cerebral arteries between 20 and 42 weeks gestation, Pregnancy Distress Questionnaire (PDQ) scores between 23 and 40 weeks gestation and neonatal outcomes. Results Concerns about physical symptoms and body image at 35–40 weeks were associated with lower odds of abnormal UAPI (OR 0.826, 95% CI 0.696 to 0.979, p=0.028). PDQ score (OR 1.073, 95% CI 1.012 to 1.137, p=0.017), concerns about birth and the baby (OR 1.143, 95% CI 1.037 to 1.260, p=0.007) and concerns about physical symptoms and body image (OR 1.283, 95% CI 1.070 to 1.538, p=0.007) at 29–34 weeks were associated with higher odds of abnormal MCA PI. Concerns about birth and the baby at 29–34 weeks (OR 1.202, 95% CI 1.018 to 1.421, p=0.030) were associated with higher odds of AEDF. Concerns about physical symptoms and body image at 35–40 weeks were

  10. Human Caring in the Social Work Context: Continued Development and Validation of a Complex Measure

    ERIC Educational Resources Information Center

    Ellis, Jacquelyn I.; Ellett, Alberta J.; DeWeaver, Kevin

    2007-01-01

    Objectives: (a) to continue the development of a measure of human caring in the context of social work practice and (b) to expand a line of inquiry exploring the relationship between human caring characteristics and the retention of public child welfare workers. Methodology: Surveys were received from a sample (n = 786) child welfare workers in…

  11. Continuous measurement of carbon black in a densely populated area of Mexico City

    NASA Astrophysics Data System (ADS)

    Peralta, O.; Ortinez, A.; Castro, T.; Espinoza, M. D. L. L.; Saavedra, I.; Carabali-Sandoval, G. A., Sr.; Páramo, V. H.; Gavilán, A.; Martínez-Arroyo, A.

    2014-12-01

    The black carbon (BC) is a byproduct of burning fossil fuels and is an important short-lived climate forcer because it absorbs solar radiation altering the Earth's radiative budget and climate. It is also an atmospheric pollutant that promotes reactions of other compounds in the atmosphere. Despite its importance for health and climate, in Mexico there are very few studies on ambient concentrations of BC in urban areas and virtually no information of continuous measurements over long periods (more than a month of measurements). So, in order to develop more efficient local and regional mitigation strategies and policies that allow reducing ambient concentrations of BC, it is necessary to know BC seasonal evolution, contribution to radiative budget and impacts on health. This study shows continuous measurements (from July 2013 to July 2014) of BC to perform an analysis of seasonal variations. The selected monitoring site is located at Iztapalapa, a densely populated area with high traffic on the southeastern part of Mexico City. BC concentrations were obtained by two aethalometers (Magee Scientific Company, models AET31 and AET42) placed 15 meters above the ground. The aethalometers operate in the wavelength range of 370-950 nm and use a standard value of mass absorption coefficient MAC = 10.8 m2/g to calculate BC environmental concentration. To correct the aethalometers readings to the conditions of Mexico City, it was employed MAC = to 6.7 m2/g, which was determined for PM2.5 with a carbon analyzer (UIC, Inc.) and represents the mass absorption coefficient of soot emitted in Mexico City. The average value of the corrected concentration of BC in Mexico City during the period from July 2013 to July 2014 was 5.39 ± 1.89 μg/m3 (1.6 higher than readings recorded by aethalometers), which is greater than that measured in Shanghai in 2014 (annual average 2.33 μg/m3) and those reported for some U.S. cities; the value implies a potential danger to the health of

  12. Effects of Esmolol on the Prevention of Haemodynamic Responses to Tracheal Extubation after Craniotomy Operations

    PubMed Central

    Alkaya, Murat Alp; Saraçoğlu, Kemal Tolga; Pehlivan, Gökhan; Eti, Zeynep; Göğüş, Fevzi Yılmaz

    2014-01-01

    Objective The aim of this study was to evaluate the effects of esmolol infusion on the prevention of haemodynamic responses to tracheal extubation in patients undergoing elective craniotomy. Methods With approval from the Medical School Ethics Committee at Marmara University and the patients’ written consent, 30 patients between 20–65 years of age undergoing elective craniotomy were randomly placed in either the Group Esmolol (n=15) or the Group Control (n=15). Anaesthesia was induced with 5–7 mg kg−1 thiopental sodium, 1 μg kg−1 remifentanil, and 0.1 mg kg−1 vecuronium bromide iv, and was maintained with 1 MAC sevoflurane in oxygen-air mixture (50:50) and 0.25 μg kg−1 min−1 remifentanil infusion. At the end of the operation, patients inhaled 100% oxygen after the discontinuation of the anaesthetic agents. For Group Esmolol, 5 min before extubation 2 mg kg−1 esmolol in 50 mL was infused over 10 min (0.2 μg kg−1 min−1), while for Group Control, 50 mL saline was infused over 10 min. The quality of extubation was evaluated with a 5 point scale, recording heat rate, systolic, diastolic, and mean arterial pressures before infusion, 1 min after infusion, during extubation, and at 1, 3, 5, and 10 min after extubation. Results In the esmolol group, systolic, diastolic, and mean arterial pressures, as well as heart rate, decreased significantly after esmolol infusion and were significantly lower than in the control group after extubation (p<0.05). The ratio of patients with an extubation score of one was significantly higher in the esmolol group than in the control group (p<0.05). Conclusion We concluded that 2 mg kg−1 esmolol infusion before extubation can prevent hypertension and tachycardia caused by extubation in patients undergoing elective craniotomy. PMID:27366396

  13. A sequence of physical processes quantified in LAOS by continuous local measures

    NASA Astrophysics Data System (ADS)

    Lee, Ching-Wei; Rogers, Simon A.

    2017-11-01

    The response to large amplitude oscillatory shear of a soft colloidal glass formed by a suspension of multiarm star polymers is investigated by means of well-defined continuous local measures. The local measures provide information regarding the transient elastic and viscous response of the material, as well as elastic extension via a shifting equilibrium position. It is shown that even when the amplitude of the strain is very large, cages reform and break twice per period and exhibit maximum elasticity around the point of zero stress. It is also shown that around the point of zero stress, the cages are extended by a nearly constant amount of approximately 5% at 1 rad/s and 7% at 10 rad/s, even when the total strain is as large as 420%. The results of this study provide a blueprint for a generic approach to elucidating the complex dynamics exhibited by soft materials under flow.

  14. SU-G-BRB-04: Automated Output Factor Measurements Using Continuous Data Logging for Linac Commissioning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, X; Li, S; Zheng, D

    Purpose: Linac commissioning is a time consuming and labor intensive process, the streamline of which is highly desirable. In particular, manual measurement of output factors for a variety of field sizes and energy greatly hinders the commissioning efficiency. In this study, automated measurement of output factors was demonstrated as ‘one-click’ using data logging of an electrometer. Methods: Beams to be measured were created in the recording and verifying (R&V) system and configured for continuous delivery. An electrometer with an automatic data logging feature enabled continuous data collection for all fields without human intervention. The electrometer saved data into a spreadsheetmore » every 0.5 seconds. A Matlab program was developed to analyze the excel data to monitor and check the data quality. Results: For each photon energy, output factors were measured for five configurations, including open field and four wedges. Each configuration includes 72 fields sizes, ranging from 4×4 to 20×30 cm{sup 2}. Using automation, it took 50 minutes to complete the measurement of 72 field sizes, in contrast to 80 minutes when using the manual approach. The automation avoided the necessity of redundant Linac status checks between fields as in the manual approach. In fact, the only limiting factor in such automation is Linac overheating. The data collection beams in the R&V system are reusable, and the simplified process is less error-prone. In addition, our Matlab program extracted the output factors faithfully from data logging, and the discrepancy between the automatic and manual measurement is within ±0.3%. For two separate automated measurements 30 days apart, consistency check shows a discrepancy within ±1% for 6MV photon with a 60 degree wedge. Conclusion: Automated output factor measurements can save time by 40% when compared with conventional manual approach. This work laid ground for further improvement for the automation of Linac commissioning.« less

  15. The dynamics of stock exchange based on the formalism of weak continuous quantum measurement

    NASA Astrophysics Data System (ADS)

    Melnyk, S.; Tuluzov, I.

    2010-07-01

    The problem of measurement in economic models and the possibility of their quantum-mechanical description are considered. It is revealed that the apparent paradox of such a description is associated with a priori requirement of conformity of the model to all the alternatives of free choice of the observer. The measurement of the state of a trader on a stock exchange is formally defined as his responses to the proposals of sale at a fixed price. It is shown that an analogue of Bell's inequalities for this measurement model is violated at the most general assumptions related to the strategy of the trader and requires a quantum-mechanical description of the dynamics of his condition. In the framework of the theory of weak continuous quantum measurements, the equation of stock price dynamics and the quantum-mechanical generalization of the F. Black and M. Scholes model for pricing options are obtained. The fundamental distinctions between the obtained model and the classical one are discussed.

  16. Continuous Evaluation of Fast Processes in Climate Models Using ARM Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Zhijin; Sha, Feng; Liu, Yangang

    2016-02-02

    This five-year award supports the project “Continuous Evaluation of Fast Processes in Climate Models Using ARM Measurements (FASTER)”. The goal of this project is to produce accurate, consistent and comprehensive data sets for initializing both single column models (SCMs) and cloud resolving models (CRMs) using data assimilation. A multi-scale three-dimensional variational data assimilation scheme (MS-3DVAR) has been implemented. This MS-3DVAR system is built on top of WRF/GSI. The Community Gridpoint Statistical Interpolation (GSI) system is an operational data assimilation system at the National Centers for Environmental Prediction (NCEP) and has been implemented in the Weather Research and Forecast (WRF) model.more » This MS-3DVAR is further enhanced by the incorporation of a land surface 3DVAR scheme and a comprehensive aerosol 3DVAR scheme. The data assimilation implementation focuses in the ARM SGP region. ARM measurements are assimilated along with other available satellite and radar data. Reanalyses are then generated for a few selected period of time. This comprehensive data assimilation system has also been employed for other ARM-related applications.« less

  17. Intercomparison of active, passive and continuous instruments for radon and radon progeny measurements in the EML chamber and test facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scarpitta, S.C.; Tu, K.W.; Fisenne, I.M.

    1996-10-01

    Results are presented from the Fifth Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurements conducted in the EML radon exposure and test facility in May 1996. In total, thirty-four government, private and academic facilities participated in the exercise with over 170 passive and electronic devices exposed in the EML test chamber. During the first week of the exercise, passive and continuous measuring devices were exposed (usually in quadruplicate) to about 1,280 Bq m{sup {minus}3} {sup 222}Rn for 1--7 days. Radon progeny measurements were made during the second week of the exercise. The results indicate thatmore » all of the tested devices that measure radon gas performed well and fulfill their intended purpose. The grand mean (GM) ratio of the participants` reported values to the EML values, for all four radon device categories, was 0.99 {plus_minus} 0.08. Eighty-five percent of all the radon measuring devices that were exposed in the EML radon test chamber were within {plus_minus}1 standard deviation (SD) of the EML reference values. For the most part, radon progeny measurements were also quite good as compared to the EML values. The GM ratio for the 10 continuous PAEC instruments was 0.90 {plus_minus} 0.12 with 75% of the devices within 1 SD of the EML reference values. Most of the continuous and integrating electronic instruments used for measuring the PAEC underestimated the EML values by about 10--15% probably because the concentration of particles onto which the radon progeny were attached was low (1,200--3,800 particles cm{sup {minus}3}). The equilibrium factor at that particle concentration level was 0.10--0.22.« less

  18. Continuous measurement of tympanic temperature with a new infrared method using an optical fiber.

    PubMed

    Shibasaki, M; Kondo, N; Tominaga, H; Aoki, K; Hasegawa, E; Idota, Y; Moriwaki, T

    1998-09-01

    The purpose of this study was to investigate the utility of an infrared tympanic thermometry by using an optical fiber for measuring tympanic temperature (Tty). In the head cooling and facial fanning tests during normothermia, right Tty measured by this method (infrared-Tty) and esophageal temperature (Tes) were not affected by decreased temple and forehead skin temperatures, suggesting that the infrared sensor in this system measured the infrared radiation from the tympanic membrane selectively. Eight male subjects took part in passive-heat-stress and progressive-exercise tests. No significant differences among infrared-Tty, the left Tty measured by thermistor (contact-Tty), and Tes were observed at rest or at the end of each experiment, and there was no significant difference in the increase in these core temperatures from rest to the end. Furthermore, there were no significant differences in the core temperature threshold at the onset of sweating and slope (the relationship of sweating rate vs. infrared-Tty and vs. contact-Tty). These results suggest that this method makes it possible to measure Tty accurately, continuously, and more safely.

  19. Continuous EEG source imaging enhances analysis of EEG-fMRI in focal epilepsy.

    PubMed

    Vulliemoz, S; Rodionov, R; Carmichael, D W; Thornton, R; Guye, M; Lhatoo, S D; Michel, C M; Duncan, J S; Lemieux, L

    2010-02-15

    EEG-correlated fMRI (EEG-fMRI) studies can reveal haemodynamic changes associated with Interictal Epileptic Discharges (IED). Methodological improvements are needed to increase sensitivity and specificity for localising the epileptogenic zone. We investigated whether the estimated EEG source activity improved models of the BOLD changes in EEG-fMRI data, compared to conventional < event-related > designs based solely on the visual identification of IED. Ten patients with pharmaco-resistant focal epilepsy underwent EEG-fMRI. EEG Source Imaging (ESI) was performed on intra-fMRI averaged IED to identify the irritative zone. The continuous activity of this estimated IED source (cESI) over the entire recording was used for fMRI analysis (cESI model). The maps of BOLD signal changes explained by cESI were compared to results of the conventional IED-related model. ESI was concordant with non-invasive data in 13/15 different types of IED. The cESI model explained significant additional BOLD variance in regions concordant with video-EEG, structural MRI or, when available, intracranial EEG in 10/15 IED. The cESI model allowed better detection of the BOLD cluster, concordant with intracranial EEG in 4/7 IED, compared to the IED model. In 4 IED types, cESI-related BOLD signal changes were diffuse with a pattern suggestive of contamination of the source signal by artefacts, notably incompletely corrected motion and pulse artefact. In one IED type, there was no significant BOLD change with either model. Continuous EEG source imaging can improve the modelling of BOLD changes related to interictal epileptic activity and this may enhance the localisation of the irritative zone. Copyright 2009 Elsevier Inc. All rights reserved.

  20. Immediate clinical and haemodynamic benefits of restoration of pulmonary valvar competence in patients with pulmonary hypertension.

    PubMed

    Lurz, P; Nordmeyer, J; Coats, L; Taylor, A M; Bonhoeffer, P; Schulze-Neick, I

    2009-04-01

    To analyse the potential benefit of restoration of pulmonary valvar competence in patients with severe pulmonary regurgitation (PR) and pulmonary hypertension (PH) associated with congenital heart disease. Retrospective study. Tertiary paediatric and adult congenital heart cardiac centre. Percutaneous pulmonary valve implantation (PPVI). All patients who underwent PPVI for treatment of PR in the presence of PH (mean PAP >25 mm Hg). Seven patients with severe PH as a result of congenital heart disease and severe PR underwent PPVI. The valve implantation procedure was feasible and uncomplicated in all seven cases, successfully abolishing PR. There was a significant increase in diastolic (15.4 (7.3) to 34.0 (8.5) mm Hg; p = 0.007) and mean (29.7 (8.1) to 41.3 (12.9) mm Hg; p = 0.034) pulmonary artery pressures, and an improvement in NYHA functional class (from median IV to median III; p<0.008). Peripheral oxygen saturations rose from 85.9% (11.0%) to 91.7% (8.3%) (p = 0.036). Right ventricular (RV) volumes decreased (from 157.0 (44.7) to 140.3 (53.3) ml/m(2)), while effective RV stroke volume increased (from 23.4 (9.3) to 41.0 (11.6) ml/m(2)). During a median follow-up of 20.3 months (range 1.3-47.5), valvar competence was well maintained despite near systemic pulmonary pressures. None of the valved stents were explanted during follow-up. Trans-catheter treatment of PR in patients with PH is well tolerated and leads to clinical and haemodynamic improvement, most probably caused by a combination of increased pulmonary perfusion pressures and RV efficiency.

  1. Continuous strife for better coverage and more details in ocean surface winds measurements - from Midori and ADEOS-2 to GCOM

    NASA Technical Reports Server (NTRS)

    Xie, X.; Liu, W.; Hu, H.; Tang, W.

    2001-01-01

    The series of joint U.S.-Japan spaceborne scatterometers missions to provide continuous measurements of ocean wind vectors is reviewed. Examples of the scientific impact of the continuous effort in improving spatial resolution and coverage are provided. The plan for the future is reviewed.

  2. First measurements of continuous δ18O-CO2 with a Fourier Transform InfraRed spectrometer in Heidelberg, Germany

    NASA Astrophysics Data System (ADS)

    Vardag, S. N.; Hammer, S.; Sabasch, M.; Griffith, D. W. T.; Levin, I.

    2014-07-01

    The continuous in-situ measurement of δ18O in atmospheric CO2 opens a new door to differentiating between CO2 source and sink components with high temporal resolution. Continuous 13C-CO2 measurement systems have been commercially available already for some time, but until now, only few instruments have been able to provide a continuous measurement of the oxygen isotope ratio in CO2. Besides precise 13C/12C observations, the Fourier Transform InfraRed (FTIR) spectrometer also measures the 18O/16O ratio of CO2, but the precision and accuracy of the measurements has not been evaluated yet. Here we present a first analysis of δ18O-CO2 (and δ13C-CO2) measurements with the FTIR in Heidelberg. We find that our spectrometer measures 18O in CO2 with a reproducibility of better than 0.3‰ at a temporal resolution of less than 10 min, as determined from surveillance gas measurements over a period of ten months. An Allan deviation test shows that the δ18O repeatability reaches 0.15‰ for half-hourly means. The compatibility of our spectroscopic measurements was determined by comparing FTIR measurements of calibration gases and ambient air to mass-spectrometric measurements of flask samples, filled with the cylinder gases or episodically collected over a diurnal cycle (event). We found that direct cylinder gas measurements agree to 0.01 ± 0.04‰ (mean and standard deviation) for δ13C-CO2 and 0.01 ± 0.11‰ for δ18O. Two weekly episodes of recent ambient air measurements, one in winter and one in summer, are discussed in view of the question, which potential insights and new challenges combined highly resolved δ18O-CO2 and δ13C-CO2 records may provide in terms of better understanding regional scale continental carbon exchange processes.

  3. Sex, ageing and resting blood pressure: gaining insights from the integrated balance of neural and haemodynamic factors.

    PubMed

    Hart, Emma C; Joyner, Michael J; Wallin, B Gunnar; Charkoudian, Nisha

    2012-05-01

    Young women tend to have lower blood pressure, and less risk of hypertension, compared to young men. As people age, both blood pressure and the risk of hypertension increase in both sexes; this occurs most strikingly in women after menopause. However, the mechanisms for these influences of sex and age remain incompletely understood. In this review we are specifically interested in the interaction between neural (sympathetic nerve activity; SNA) and haemodynamic factors (cardiac output, blood pressure and vascular resistance) and how these change with sex and age. While peripheral vascular SNA can vary 7- to 10-fold among normotensive young men and women, it is reproducible in a given individual. Surprisingly, higher levels of SNA are not associated with higher blood pressures in these groups. In young men, high SNA is associated with higher total peripheral vascular resistance (TPR), and appears to be balanced by lower cardiac output and less peripheral vascular responsiveness to adrenergic stimulation. Young women do not exhibit the SNA-TPR relationship. Recent evidence suggests that β-adrenergic vasodilatation offsets the vasoconstrictor effects of α-adrenergic vasoconstriction in young women, which may contribute to the generally lower blood pressures in this group. Sympathetic nerve activity increases with age, and in groups over 40, levels of SNA are more tightly linked to levels of blood pressure. The potentially protective β-adrenergic effect seen in young women appears to be lost after menopause and probably contributes to the increased blood pressure and increased risk of hypertension seen in older women.

  4. Measurements of liquid phase residence time distributions in a pilot-scale continuous leaching reactor using radiotracer technique.

    PubMed

    Pant, H J; Sharma, V K; Shenoy, K T; Sreenivas, T

    2015-03-01

    An alkaline based continuous leaching process is commonly used for extraction of uranium from uranium ore. The reactor in which the leaching process is carried out is called a continuous leaching reactor (CLR) and is expected to behave as a continuously stirred tank reactor (CSTR) for the liquid phase. A pilot-scale CLR used in a Technology Demonstration Pilot Plant (TDPP) was designed, installed and operated; and thus needed to be tested for its hydrodynamic behavior. A radiotracer investigation was carried out in the CLR for measurement of residence time distribution (RTD) of liquid phase with specific objectives to characterize the flow behavior of the reactor and validate its design. Bromine-82 as ammonium bromide was used as a radiotracer and about 40-60MBq activity was used in each run. The measured RTD curves were treated and mean residence times were determined and simulated using a tanks-in-series model. The result of simulation indicated no flow abnormality and the reactor behaved as an ideal CSTR for the range of the operating conditions used in the investigation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Impact of anticoagulation therapy on valve haemodynamic deterioration following transcatheter aortic valve replacement.

    PubMed

    Del Trigo, María; Muñoz-García, Antonio J; Latib, Azeem; Auffret, Vincent; Wijeysundera, Harindra C; Nombela-Franco, Luis; Gutierrez, Enrique; Cheema, Asim N; Serra, Vicenç; Amat-Santos, Ignacio J; Kefer, Joelle; Benitez, Luis Miguel; Leclercq, Florence; Mangieri, Antonio; Le Breton, Hervé; Jiménez-Quevedo, Pilar; Garcia Del Blanco, Bruno; Dager, Antonio; Abdul-Jawad Altisent, Omar; Puri, Rishi; Pibarot, Philippe; Rodés-Cabau, Josep

    2018-05-01

    To evaluate the changes in transvalvular gradients and the incidence of valve haemodynamic deterioration (VHD) following transcatheter aortic valve replacement (TAVR), according to use of anticoagulation therapy. This multicentre study included 2466 patients (46% men; mean age 81±7 years) who underwent TAVR with echocardiography performed at 12-month follow-up. Anticoagulation therapy was used in 707 patients (28.7%) following TAVR (AC group). A total of 663 patients received vitamin K antagonists, and 44 patients received direct oral anticoagulants. A propensity score matching analysis was performed to adjust for intergroup (AC vs non-AC post-TAVR) differences. A total of 622 patients per group were included in the propensity-matched analysis. VHD was defined as a ≥10 mm Hg increase in the mean transprosthetic gradient at follow-up (vs hospital discharge). The mean clinical follow-up was 29±18 months. The mean transvalvular gradient significantly increased at follow-up in the non-AC group within the global cohort (P=0.003), whereas it remained stable over time in the AC group (P=0.323). The incidence of VHD was significantly lower in the AC group (0.6%) compared with the non-AC group (3.7%, P<0.001), and these significant differences remained within the propensity-matched populations (0.6% vs 3.9% in the AC and non-AC groups, respectively, P<0.001). The occurrence of VHD did not associate with an increased risk of all-cause death (P=0.468), cardiovascular death (P=0.539) or stroke (P=0.170) at follow-up. The lack of anticoagulation therapy post-TAVR was associated with significant increments in transvalvular gradients and a greater risk of VHD. VHD was subclinical in most cases and did not associate with major adverse clinical events. Future randomised trials are needed to determine if systematic anticoagulation therapy post-TAVR would reduce the incidence of VHD. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article

  6. Evolution of target organ damage and haemodynamic parameters over 4 years in patients with increased insulin resistance: the LOD-DIABETES prospective observational study

    PubMed Central

    Gómez-Marcos, Manuel Ángel; Recio-Rodríguez, José Ignacio; Patino-Alonso, María Carmen; Agudo-Conde, Cristina; Rodríguez-Sanchez, Emiliano; Maderuelo-Fernandez, Jose Angel; Gómez-Sánchez, Leticia; Gomez-Sanchez, Marta; García-Ortiz, Luís

    2016-01-01

    Objectives We prospectively examined the impact of type 2 diabetes compared with metabolic syndrome (MetS) on the development of vascular disease over 4 years as determined by anatomic and functional markers of vascular disease. By comparing the vascular outcomes of the 2 disorders, we seek to determine the independent effect of elevated glucose levels on vascular disease. Setting 2 primary care centres in Salamanca, Spain. Participants We performed a prospective observational study involving 112 patients (68 with type 2 diabetes and 44 with MetS) who were followed for 4 years. Primary and secondary outcome measures Measurements included blood pressure, blood glucose, lipids, smoking, body mass index, waist circumference, Homeostasis Model Assessment Insulin Resistance (HOMA-IR), hs-c-reactive protein and fibrinogen levels. We also evaluated vascular, carotid intima media thickness (IMT), pulse wave velocity (PWV) and ankle/brachial index, heart and renal target organ damage (TOD). The haemodynamic parameters were central (CAIx) and peripheral (PAIx) augmentation indices. Results In year 4, participants with type 2 diabetes had increased IMT thickness. These patients had more plaques and an IMT>0.90 mm. In participants with MetS, we only found an increase in the number of plaques. We found no changes in PWV, CAIx and PAIx. The patients with diabetes had a greater frequency of vascular TOD. There were no differences neither in renal nor cardiac percentage of TOD in the patients with MetS or diabetes mellitus type 2. Conclusions This prospective study showed that the evolution of vascular TOD is different in participants with type 2 diabetes compared with those with MetS. While IMT and PWV increased in type 2 diabetes, these were not modified in MetS. The renal and cardiac TOD evolution, as well as the PAIx and CAIx, did not change in either group. Trial registration number NCT01065155; Results. PMID:27251684

  7. Mediation analysis when a continuous mediator is measured with error and the outcome follows a generalized linear model

    PubMed Central

    Valeri, Linda; Lin, Xihong; VanderWeele, Tyler J.

    2014-01-01

    Mediation analysis is a popular approach to examine the extent to which the effect of an exposure on an outcome is through an intermediate variable (mediator) and the extent to which the effect is direct. When the mediator is mis-measured the validity of mediation analysis can be severely undermined. In this paper we first study the bias of classical, non-differential measurement error on a continuous mediator in the estimation of direct and indirect causal effects in generalized linear models when the outcome is either continuous or discrete and exposure-mediator interaction may be present. Our theoretical results as well as a numerical study demonstrate that in the presence of non-linearities the bias of naive estimators for direct and indirect effects that ignore measurement error can take unintuitive directions. We then develop methods to correct for measurement error. Three correction approaches using method of moments, regression calibration and SIMEX are compared. We apply the proposed method to the Massachusetts General Hospital lung cancer study to evaluate the effect of genetic variants mediated through smoking on lung cancer risk. PMID:25220625

  8. Sensor for In-Motion Continuous 3D Shape Measurement Based on Dual Line-Scan Cameras

    PubMed Central

    Sun, Bo; Zhu, Jigui; Yang, Linghui; Yang, Shourui; Guo, Yin

    2016-01-01

    The acquisition of three-dimensional surface data plays an increasingly important role in the industrial sector. Numerous 3D shape measurement techniques have been developed. However, there are still limitations and challenges in fast measurement of large-scale objects or high-speed moving objects. The innovative line scan technology opens up new potentialities owing to the ultra-high resolution and line rate. To this end, a sensor for in-motion continuous 3D shape measurement based on dual line-scan cameras is presented. In this paper, the principle and structure of the sensor are investigated. The image matching strategy is addressed and the matching error is analyzed. The sensor has been verified by experiments and high-quality results are obtained. PMID:27869731

  9. Using continuous underway isotope measurements to map water residence time in hydrodynamically complex tidal environments

    USGS Publications Warehouse

    Downing, Bryan D.; Bergamaschi, Brian; Kendall, Carol; Kraus, Tamara; Dennis, Kate J.; Carter, Jeffery A.; von Dessonneck, Travis

    2016-01-01

    Stable isotopes present in water (δ2H, δ18O) have been used extensively to evaluate hydrological processes on the basis of parameters such as evaporation, precipitation, mixing, and residence time. In estuarine aquatic habitats, residence time (τ) is a major driver of biogeochemical processes, affecting trophic subsidies and conditions in fish-spawning habitats. But τ is highly variable in estuaries, owing to constant changes in river inflows, tides, wind, and water height, all of which combine to affect τ in unpredictable ways. It recently became feasible to measure δ2H and δ18O continuously, at a high sampling frequency (1 Hz), using diffusion sample introduction into a cavity ring-down spectrometer. To better understand the relationship of τ to biogeochemical processes in a dynamic estuarine system, we continuously measured δ2H and δ18O, nitrate and water quality parameters, on board a small, high-speed boat (5 to >10 m s–1) fitted with a hull-mounted underwater intake. We then calculated τ as is classically done using the isotopic signals of evaporation. The result was high-resolution (∼10 m) maps of residence time, nitrate, and other parameters that showed strong spatial gradients corresponding to geomorphic attributes of the different channels in the area. The mean measured value of τ was 30.5 d, with a range of 0–50 d. We used the measured spatial gradients in both τ and nitrate to calculate whole-ecosystem uptake rates, and the values ranged from 0.006 to 0.039 d–1. The capability to measure residence time over single tidal cycles in estuaries will be useful for evaluating and further understanding drivers of phytoplankton abundance, resolving differences attributable to mixing and water sources, explicitly calculating biogeochemical rates, and exploring the complex linkages among time-dependent biogeochemical processes in hydrodynamically complex environments such as estuaries.

  10. High-accuracy continuous airborne measurements of greenhouse gases (CO2 and CH4) during BARCA

    NASA Astrophysics Data System (ADS)

    Chen, H.; Winderlich, J.; Gerbig, C.; Hoefer, A.; Rella, C. W.; Crosson, E. R.; van Pelt, A. D.; Steinbach, J.; Kolle, O.; Beck, V.; Daube, B. C.; Gottlieb, E. W.; Chow, V. Y.; Santoni, G. W.; Wofsy, S. C.

    2009-12-01

    High-accuracy continuous measurements of greenhouse gases (CO2 and CH4) during the BARCA (Balanço Atmosférico Regional de Carbono na Amazônia) phase B campaign in Brazil in May 2009 were accomplished using a newly available analyzer based on the cavity ring-down spectroscopy (CRDS) technique. This analyzer was flown without a drying system or any in-flight calibration gases. Water vapor corrections associated with dilution and pressure-broadening effects for CO2 and CH4 were derived from laboratory experiments employing measurements of water vapor by the CRDS analyzer. Before the campaign, the stability of the analyzer was assessed by laboratory tests under simulated flight conditions. During the campaign, a comparison of CO2 measurements between the CRDS analyzer and a nondispersive infrared (NDIR) analyzer on board the same aircraft showed a mean difference of 0.22±0.09 ppm for all flights over the Amazon rain forest. At the end of the campaign, CO2 concentrations of the synthetic calibration gases used by the NDIR analyzer were determined by the CRDS analyzer. After correcting for the isotope and the pressure-broadening effects that resulted from changes of the composition of synthetic vs. ambient air, and applying those concentrations as calibrated values of the calibration gases to reprocess the CO2 measurements made by the NDIR, the mean difference between the CRDS and the NDIR during BARCA was reduced to 0.05±0.09 ppm, with the mean standard deviation of 0.23±0.05 ppm. The results clearly show that the CRDS is sufficiently stable to be used in flight without drying the air or calibrating in flight and the water corrections are fully adequate for high-accuracy continuous airborne measurements of CO2 and CH4.

  11. Detectability of Arctic methane sources at six sites performing continuous atmospheric measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thonat, Thibaud; Saunois, Marielle; Bousquet, Philippe

    Understanding the recent evolution of methane emissions in the Arctic is necessary to interpret the global methane cycle. Emissions are affected by significant uncertainties and are sensitive to climate change, leading to potential feedbacks. A polar version of the CHIMERE chemistry-transport model is used to simulate the evolution of tropospheric methane in the Arctic during 2012, including all known regional anthropogenic and natural sources, in particular freshwater emissions which are often overlooked in methane modelling. CHIMERE simulations are compared to atmospheric continuous observations at six measurement sites in the Arctic region. In winter, the Arctic is dominated by anthropogenic emissions;more » emissions from continental seepages and oceans, including from the East Siberian Arctic Shelf, can contribute significantly in more limited areas. In summer, emissions from wetland and freshwater sources dominate across the whole region. The model is able to reproduce the seasonality and synoptic variations of methane measured at the different sites. We find that all methane sources significantly affect the measurements at all stations at least at the synoptic scale, except for biomass burning. In particular, freshwater systems play a decisive part in summer, representing on average between 11 and 26 % of the simulated Arctic methane signal at the sites. This indicates the relevance of continuous observations to gain a mechanistic understanding of Arctic methane sources. Sensitivity tests reveal that the choice of the land-surface model used to prescribe wetland emissions can be critical in correctly representing methane mixing ratios. The closest agreement with the observations is reached when using the two wetland models which have emissions peaking in August–September, while all others reach their maximum in June–July. Such phasing provides an interesting constraint on wetland models which still have large uncertainties at present. Also testing

  12. Detectability of Arctic methane sources at six sites performing continuous atmospheric measurements

    DOE PAGES

    Thonat, Thibaud; Saunois, Marielle; Bousquet, Philippe; ...

    2017-07-11

    Understanding the recent evolution of methane emissions in the Arctic is necessary to interpret the global methane cycle. Emissions are affected by significant uncertainties and are sensitive to climate change, leading to potential feedbacks. A polar version of the CHIMERE chemistry-transport model is used to simulate the evolution of tropospheric methane in the Arctic during 2012, including all known regional anthropogenic and natural sources, in particular freshwater emissions which are often overlooked in methane modelling. CHIMERE simulations are compared to atmospheric continuous observations at six measurement sites in the Arctic region. In winter, the Arctic is dominated by anthropogenic emissions;more » emissions from continental seepages and oceans, including from the East Siberian Arctic Shelf, can contribute significantly in more limited areas. In summer, emissions from wetland and freshwater sources dominate across the whole region. The model is able to reproduce the seasonality and synoptic variations of methane measured at the different sites. We find that all methane sources significantly affect the measurements at all stations at least at the synoptic scale, except for biomass burning. In particular, freshwater systems play a decisive part in summer, representing on average between 11 and 26 % of the simulated Arctic methane signal at the sites. This indicates the relevance of continuous observations to gain a mechanistic understanding of Arctic methane sources. Sensitivity tests reveal that the choice of the land-surface model used to prescribe wetland emissions can be critical in correctly representing methane mixing ratios. The closest agreement with the observations is reached when using the two wetland models which have emissions peaking in August–September, while all others reach their maximum in June–July. Such phasing provides an interesting constraint on wetland models which still have large uncertainties at present. Also testing

  13. Detectability of Arctic methane sources at six sites performing continuous atmospheric measurements

    NASA Astrophysics Data System (ADS)

    Thonat, Thibaud; Saunois, Marielle; Bousquet, Philippe; Pison, Isabelle; Tan, Zeli; Zhuang, Qianlai; Crill, Patrick M.; Thornton, Brett F.; Bastviken, David; Dlugokencky, Ed J.; Zimov, Nikita; Laurila, Tuomas; Hatakka, Juha; Hermansen, Ove; Worthy, Doug E. J.

    2017-07-01

    Understanding the recent evolution of methane emissions in the Arctic is necessary to interpret the global methane cycle. Emissions are affected by significant uncertainties and are sensitive to climate change, leading to potential feedbacks. A polar version of the CHIMERE chemistry-transport model is used to simulate the evolution of tropospheric methane in the Arctic during 2012, including all known regional anthropogenic and natural sources, in particular freshwater emissions which are often overlooked in methane modelling. CHIMERE simulations are compared to atmospheric continuous observations at six measurement sites in the Arctic region. In winter, the Arctic is dominated by anthropogenic emissions; emissions from continental seepages and oceans, including from the East Siberian Arctic Shelf, can contribute significantly in more limited areas. In summer, emissions from wetland and freshwater sources dominate across the whole region. The model is able to reproduce the seasonality and synoptic variations of methane measured at the different sites. We find that all methane sources significantly affect the measurements at all stations at least at the synoptic scale, except for biomass burning. In particular, freshwater systems play a decisive part in summer, representing on average between 11 and 26 % of the simulated Arctic methane signal at the sites. This indicates the relevance of continuous observations to gain a mechanistic understanding of Arctic methane sources. Sensitivity tests reveal that the choice of the land-surface model used to prescribe wetland emissions can be critical in correctly representing methane mixing ratios. The closest agreement with the observations is reached when using the two wetland models which have emissions peaking in August-September, while all others reach their maximum in June-July. Such phasing provides an interesting constraint on wetland models which still have large uncertainties at present. Also testing different

  14. Continuous optical measurement system of hemolysis during a photosensitization reaction using absorption spectrum

    NASA Astrophysics Data System (ADS)

    Hamada, R.; Ogawa, E.; Arai, T.

    2018-02-01

    To investigate hemolysis phenomena during a photosensitization reaction with the reaction condition continuously and simultaneously for a safety assessment of hemolysis side effect, we constructed an optical system to measure blood sample absorption spectrum during the reaction. Hemolysis degree might be under estimated in general evaluation methods because there is a constant oxygen pressure assumption in spite of oxygen depression take place. By investigating hemoglobin oxidation and oxygen desorption dynamics obtained from the contribution of the visible absorption spectrum and multiple regression analysis, both the hemolysis phenomena and its oxygen environment might be obtained with time. A 664 nm wavelength laser beam for the reaction excitation and 475-650 nm light beam for measuring the absorbance spectrum were arranged perpendicularly crossing. A quartz glass cuvette with 1×10 mm in dimensions for the spectrum measurement was located at this crossing point. A red blood cells suspension medium was arranged with low hematocrit containing 30 μg/ml talaporfin sodium. This medium was irradiated up to 40 J/cm2 . The met-hemoglobin, oxygenatedhemoglobin, and deoxygenated-hemoglobin concentrations were calculated by a multiple regression analysis from the measured spectra. We confirmed the met-hemoglobin concentration increased and oxygen saturation decreased with the irradiation time, which seems to indicate the hemolysis progression and oxygen consumption, respectively. By using our measuring system, the hemolysis progression seems to be obtained with oxygen environment information.

  15. Continuous performance task in ADHD: Is reaction time variability a key measure?

    PubMed

    Levy, Florence; Pipingas, Andrew; Harris, Elizabeth V; Farrow, Maree; Silberstein, Richard B

    2018-01-01

    To compare the use of the Continuous Performance Task (CPT) reaction time variability (intraindividual variability or standard deviation of reaction time), as a measure of vigilance in attention-deficit hyperactivity disorder (ADHD), and stimulant medication response, utilizing a simple CPT X-task vs an A-X-task. Comparative analyses of two separate X-task vs A-X-task data sets, and subgroup analyses of performance on and off medication were conducted. The CPT X-task reaction time variability had a direct relationship to ADHD clinician severity ratings, unlike the CPT A-X-task. Variability in X-task performance was reduced by medication compared with the children's unmedicated performance, but this effect did not reach significance. When the coefficient of variation was applied, severity measures and medication response were significant for the X-task, but not for the A-X-task. The CPT-X-task is a useful clinical screening test for ADHD and medication response. In particular, reaction time variability is related to default mode interference. The A-X-task is less useful in this regard.

  16. A systematic review of statistical methods used to test for reliability of medical instruments measuring continuous variables.

    PubMed

    Zaki, Rafdzah; Bulgiba, Awang; Nordin, Noorhaire; Azina Ismail, Noor

    2013-06-01

    Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice. In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. The Intra-class Correlation Coefficient (ICC) is the most popular method with 25 (60%) studies having used this method followed by the comparing means (8 or 19%). Out of 25 studies using the ICC, only 7 (28%) reported the confidence intervals and types of ICC used. Most studies (71%) also tested the agreement of instruments. This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  17. Intensity-Modulated Continuous-Wave Lidar at 1.57 Micrometer for Atmospheric CO2 Measurements

    NASA Technical Reports Server (NTRS)

    Lin, Bing; Ismail, Syed; Browell, Edward; Meadows, Byron; Nehrir, Amin; Harrison, Wallace F.; Dobler, Jeremy; Obland, Michael

    2014-01-01

    Understanding the earth's carbon cycle is essential for diagnosing current and predicting future climates, which requires precise global measurements of atmospheric CO2 through space missions. The Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission will provide accurate global atmospheric CO2 measurements to meet carbon science requirements. The joint team of NASA Langley Research Center and ITT Exelis, Inc proposes to use the intensity-modulated, continuous-wave (IM-CW) lidar approach for the ASCENDS mission. Prototype instruments have been developed and used to demonstrate the power, signal-to-noise ratio, precision and accuracy, spectral purity, and stability of the measurement and the instrument needed for atmospheric CO2 observations from space. The ranging capability from laser platform to ground surfaces or intermediate backscatter layers is achieved by transmitted range-encoded IM laser signals. Based on the prototype instruments and current lidar technologies, space lidar systems and their CO2 column measurements are analyzed. These studies exhibit a great potential of using IM-CW lidar system for the active space CO2 mission ASCENDS.

  18. The Measurement of Aerosol Optical Properties Using Continuous Wave Cavity Ring-Down Techniques

    NASA Technical Reports Server (NTRS)

    Strawa, A. W.; Owano, T.; Castaneda, R.; Baer, D. S.; Paldus, B. A.; Gore, Warren J. (Technical Monitor)

    2002-01-01

    Large uncertainties in the effects that aerosols have on climate require improved in-situ measurements of extinction coefficient and single-scattering albedo. This abstract describes the use of continuous wave cavity ring-down (CW-CRD) technology to address this problem. The innovations in this instrument are the use of CW-CRD to measure aerosol extinction coefficient, the simultaneous measurement of scattering coefficient, and small size suitable for a wide range of aircraft applications. Our prototype instrument measures extinction and scattering coefficient at 690 nm and extinction coefficient at 1550 nm. The instrument itself is small (60 x 48 x 15 cm) and relatively insensitive to vibrations. The prototype instrument has been tested in our lab and used in the field. While improvements in performance are needed, the prototype has been shown to make accurate and sensitive measurements of extinction and scattering coefficients. Combining these two parameters, one can obtain the single-scattering albedo and absorption coefficient, both important aerosol properties. The use of two wavelengths also allows us to obtain a quantitative idea of the size of the aerosol through the Angstrom exponent. Minimum sensitivity of the prototype instrument is 1.5 x 10(exp -6)/m (1.5/Mm). Validation of the measurement of extinction coefficient has been accomplished by comparing the measurement of calibration spheres with Mie calculations. This instrument and its successors have potential to help reduce uncertainty currently associated with aerosol optical properties and their spatial and temporal variation. Possible applications include studies of visibility, climate forcing by aerosol, and the validation of aerosol retrieval schemes from satellite data.

  19. Development and validation of a continuous measure of patient condition using the Electronic Medical Record.

    PubMed

    Rothman, Michael J; Rothman, Steven I; Beals, Joseph

    2013-10-01

    Patient condition is a key element in communication between clinicians. However, there is no generally accepted definition of patient condition that is independent of diagnosis and that spans acuity levels. We report the development and validation of a continuous measure of general patient condition that is independent of diagnosis, and that can be used for medical-surgical as well as critical care patients. A survey of Electronic Medical Record data identified common, frequently collected non-static candidate variables as the basis for a general, continuously updated patient condition score. We used a new methodology to estimate in-hospital risk associated with each of these variables. A risk function for each candidate input was computed by comparing the final pre-discharge measurements with 1-year post-discharge mortality. Step-wise logistic regression of the variables against 1-year mortality was used to determine the importance of each variable. The final set of selected variables consisted of 26 clinical measurements from four categories: nursing assessments, vital signs, laboratory results and cardiac rhythms. We then constructed a heuristic model quantifying patient condition (overall risk) by summing the single-variable risks. The model's validity was assessed against outcomes from 170,000 medical-surgical and critical care patients, using data from three US hospitals. Outcome validation across hospitals yields an area under the receiver operating characteristic curve(AUC) of ≥0.92 when separating hospice/deceased from all other discharge categories, an AUC of ≥0.93 when predicting 24-h mortality and an AUC of 0.62 when predicting 30-day readmissions. Correspondence with outcomes reflective of patient condition across the acuity spectrum indicates utility in both medical-surgical units and critical care units. The model output, which we call the Rothman Index, may provide clinicians with a longitudinal view of patient condition to help address known

  20. Dynamics of the brain: Mathematical models and non-invasive experimental studies

    NASA Astrophysics Data System (ADS)

    Toronov, V.; Myllylä, T.; Kiviniemi, V.; Tuchin, V. V.

    2013-10-01

    Dynamics is an essential aspect of the brain function. In this article we review theoretical models of neural and haemodynamic processes in the human brain and experimental non-invasive techniques developed to study brain functions and to measure dynamic characteristics, such as neurodynamics, neurovascular coupling, haemodynamic changes due to brain activity and autoregulation, and cerebral metabolic rate of oxygen. We focus on emerging theoretical biophysical models and experimental functional neuroimaging results, obtained mostly by functional magnetic resonance imaging (fMRI) and near-infrared spectroscopy (NIRS). We also included our current results on the effects of blood pressure variations on cerebral haemodynamics and simultaneous measurements of fast processes in the brain by near-infrared spectroscopy and a very novel functional MRI technique called magnetic resonance encephalography. Based on a rapid progress in theoretical and experimental techniques and due to the growing computational capacities and combined use of rapidly improving and emerging neuroimaging techniques we anticipate during next decade great achievements in the overall knowledge of the human brain.

  1. Continuous measurement of intra-oral pH and temperature: development, validation of an appliance and a pilot study.

    PubMed

    Choi, J E; Loke, C; Waddell, J N; Lyons, K M; Kieser, J A; Farella, M

    2015-08-01

    To describe a novel approach for continuous measurement of intra-oral pH and temperature in individuals carrying out normal daily activities over 24 h. We designed, validated and constructed a custom-made appliance fitted with a pH probe and a thermocouple. Six subjects wore the appliance over a 24-h period for two non-consecutive days, while the intra-oral pH and temperature were measured continuously and recorded. Intra-oral pH and temperature were very similar across different recording days, the difference being not statistically significant (P ≥ 0.14). There was a noticeable difference in the pattern of variation of pH between day and night. During the day, the mean pH was 7.3 (±0.4) and dropped markedly only after consumption of acidic food and drinks. The intra-oral pH decreased slowly during sleep with an average pH of 6.6 (±0.4) being recorded. The difference between day and night was statistically significant (P = 0.002). The mean intra-oral temperature was 33.9 °C (±0.9) during daytime and 35·9 °C (±0·5) during sleep (P = 0.013) with minor fluctuations occurring over 24 h. The continuous and simultaneous intra-oral pH and temperature measurement system described in this report is reliable, easy to construct, able to measure variables over a sustained period and may serve as a future diagnostic tool in a number of applications. © 2015 John Wiley & Sons Ltd.

  2. Characterization of a customized calibration unit for continuous measurements of the isotopic composition of water vapor

    NASA Astrophysics Data System (ADS)

    Moro, Giovanni; Zannoni, Daniele; Dreossi, Giuliano; Stenni, Barbara

    2017-04-01

    The objective of this work is the development, standardization and creation of a method to carry out continuous measurement of oxygen and hydrogen isotopic composition of the atmospheric water vapor using a wavelength-scanned cavity ring down spectroscopy (WS-CRDS) instrument produced by Picarro, L1102-i model. Some technical improvements of the standard instrument configuration have been made to create three different inlet gas lines: a "standard" line, a calibration line and a line connected with the external sampler. The calibration line is composed of a syringe-pump that continuously injects standard water into a steel tee heated at the temperature of 170°C and flushed with dry nitrogen gas. In this way, instantaneous and complete vaporization of the standard water takes place. The resulting steam is characterized by a well-defined composition in δD e δ18O values. To allow comparison with other international data, we have characterized the individual instrumental response to variation of the isotopic composition of the water vapor. Several humidity-isotope response functions (6000-26000 ppmv) have been estimated with three different internal standards (0.35‰ -8.75‰ -29.11‰ and -40.28‰ for δ18O; 2.31‰ -58.91‰ -222.19‰ and -317.78‰ for δD). Moreover, we have measured the instrumental drift at regular time intervals to apply the opportune corrections to instrument data. The setup has been tested using a 3.5 day continuous measurements carried out with the Picarro sampling the water vapor outside our campus in Venice and parallel sampling using the classical cryogenic trapping procedure, obtaining excellent results. Furthermore, our analysis technique has given good results for the standards with values which are similar to those obtained with the isotope ratio mass spectrometry (IRMS) technique.

  3. Apparatus for continuous, fast, and precise measurements of position and velocity of a small spherical particle

    NASA Technical Reports Server (NTRS)

    Venkataraman, T. S.; Eidson, W. W.; Cohen, L. D.; Farina, J. D.; Acquista, C.

    1983-01-01

    The position and velocity of optically levitated glass spheres (radii 10-20 microns) movng in a gas are measured accurately, rapidly, and continuously using a high-speed rotating polygon mirror. The experimental technique developed here has repeatable position accuracies better than 20 microns. Each measurement takes less than 1 microsec and can be repeated every 100 microsec. The position of the levitated glass spheres can be manipulated accurately by modulating the laser power with an acoustic optic modulator. The technique provides a fast and accurate method to study general particle dynamics in a fluid.

  4. Accurate respiration measurement using DC-coupled continuous-wave radar sensor for motion-adaptive cancer radiotherapy.

    PubMed

    Gu, Changzhan; Li, Ruijiang; Zhang, Hualiang; Fung, Albert Y C; Torres, Carlos; Jiang, Steve B; Li, Changzhi

    2012-11-01

    Accurate respiration measurement is crucial in motion-adaptive cancer radiotherapy. Conventional methods for respiration measurement are undesirable because they are either invasive to the patient or do not have sufficient accuracy. In addition, measurement of external respiration signal based on conventional approaches requires close patient contact to the physical device which often causes patient discomfort and undesirable motion during radiation dose delivery. In this paper, a dc-coupled continuous-wave radar sensor was presented to provide a noncontact and noninvasive approach for respiration measurement. The radar sensor was designed with dc-coupled adaptive tuning architectures that include RF coarse-tuning and baseband fine-tuning, which allows the radar sensor to precisely measure movement with stationary moment and always work with the maximum dynamic range. The accuracy of respiration measurement with the proposed radar sensor was experimentally evaluated using a physical phantom, human subject, and moving plate in a radiotherapy environment. It was shown that respiration measurement with radar sensor while the radiation beam is on is feasible and the measurement has a submillimeter accuracy when compared with a commercial respiration monitoring system which requires patient contact. The proposed radar sensor provides accurate, noninvasive, and noncontact respiration measurement and therefore has a great potential in motion-adaptive radiotherapy.

  5. The portable device for continual measurement of radon progenies on filter using the detector Timepix.

    PubMed

    Bulanek, Boris; Hulka, Jiri; Jilek, Karel; Stekl, Ivan

    2015-06-01

    In this article, a portable device was presented for continual measuring of equilibrium equivalent concentration (EEC) of (222)Rn based on the Timepix detector with 300-µm-thick active layer. In order to have a portable device, a filtration head was developed for collecting short-lived radon progenies attached on aerosols. The short-lived progenies are estimated from analysing alphas from decay of (218,214)Po from Millipore filter after termination of filtration. Comparison with beta measurement was done as well. The dependence of EEC on an air flow and filtration time was studied. The low-level detection limit for EEC was estimated from the last 10 min of 3-h decay measurement and was found in the range of 40-70 Bq m(-3). EEC was measured in National Radiation Protection Institute radon chamber, and results were compared with the commercial detector Fritra4. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Impact of TGF for aircrew dosimetry: analysis of continuous onboard measurements

    NASA Astrophysics Data System (ADS)

    Trompier, Francois; Fuller, Nicolas; Bonnotte, Frank; Desmaris, Gérard; Musso, Angelica; Cale, Eric; Bottollier-Depois, Jean-François

    2014-05-01

    The actual assessment of the occupational exposure of aircrew to cosmic radiation is performed in routine by software based on the crossing of route flight data with dose rate maps of the atmosphere obtained by simulation or elaborated with model based on measured data. In addition of the galactic component, some of these softwares take into account also the possible increase of dose from solar flares. In several publications, terrestrial gamma-rays flashes (TGF) are also investigated as a possible source of exposure of aircrew. Up to now, the evaluation of the impact of TGF in terms of dose onboard aircraft has been performed only by calculation. According to these publications, if the airplane is located in or near the high-field region during the lightning discharge, doses could reach the order of 100 of mSv, which far exceed the annual dose limit for workers (1). To our knowledge, no measured data has been yet reported for such phenomena that could confirm or not the order of magnitude of dose from TGF or the frequency or the probability of occurrence of such phenomena. To investigate further the TGF effect, it is recommended to perform measurements onboard airplanes. Since the beginning of 2013, the Institute of Radiation Protection and nuclear Safety (IRSN) in cooperation with Air France is running a campaign of continuous measurements with active devices aiming to measure effect on dose rate of solar flare. These measurements are used to improve models used to estimate the doses from Ground Level Event (GLE). In addition, passive dosimeters were historically installed in Air France airplanes and read out every three months constituting a very large database of dose measurements. All these data will be analyzed to better characterize the possible influence on dose from TGF. The statistical analysis of these data offers the possibility to estimate the order of magnitude of possible additional doses to aircrew due to TGF and/or to evaluate the probability of

  7. The Measurement of Aerosol Optical Properties using Continuous Wave Cavity Ring-Down Techniques

    NASA Technical Reports Server (NTRS)

    Strawa, Anthony W.; Castaneda, Rene; Owano, Thomas; Baer, Douglas S.; Paldus, Barbara A.; Gore, Warren J. (Technical Monitor)

    2002-01-01

    Large uncertainties in the effects that aerosols have on climate require improved in situ measurements of extinction coefficient and single-scattering albedo. This paper describes the use of continuous wave cavity ring-down (CW-CRD) technology to address this problem. The innovations in this instrument are the use of CW-CRD to measure aerosol extinction coefficient, the simultaneous measurement of scattering coefficient, and small size suitable for a wide range of aircraft applications. Our prototype instrument measures extinction and scattering coefficient at 690 nm and extinction coefficient at 1550 nm. The instrument itself is small (60 x 48 x 15 cm) and relatively insensitive to vibrations. The prototype instrument has been tested in our lab and used in the field. While improvements in performance are needed, the prototype has been shown to make accurate and sensitive measurements of extinction and scattering coefficients. Combining these two parameters, one can obtain the single-scattering albedo and absorption coefficient, both important aerosol properties. The use of two wavelengths also allows us to obtain a quantitative idea of the size of the aerosol through the Angstrom exponent. Minimum sensitivity of the prototype instrument is 1.5 x 10(exp -6)/m (1.5 M/m). Validation of the measurement of extinction coefficient has been accomplished by comparing the measurement of calibration spheres with Mie calculations. This instrument and its successors have potential to help reduce uncertainty currently associated with aerosol optical properties and their spatial and temporal variation. Possible applications include studies of visibility, climate forcing by aerosol, and the validation of aerosol retrieval schemes from satellite data.

  8. Reconstruction of the in-plane mode shape of a rotating tire with a continuous scanning measurement using the Hilbert-Huang transform.

    PubMed

    Lee, Jongsuh; Wang, Semyung; Pluymers, Bert; Desmet, Wim; Kindt, Peter

    2015-02-01

    Generally, the dynamic characteristics (natural frequency, damping, and mode shape) of a structure can be estimated by experimental modal analysis. Among these dynamic characteristics, mode shape requires multiple measurements of the structure at different positions, which increases the experimental cost and time. Recently, the Hilbert-Huang transform (HHT) method has been introduced to extract mode-shape information from a continuous measurement, which requires vibration measurements from one position to another position continuously with a non-contact sensor. In this research study, an effort has been made to estimate the mode shapes of a rolling tire with a single measurement instead of using the conventional experimental setup (i.e., measurement of the vibration of a rolling tire at multiple positions similar to the case of a non-rotating structure), which is used to estimate the dynamic behavior of a rolling tire. For this purpose, HHT, which was used in the continuous measurement of a non-rotating structure in previous research studies, has been used for the case of a rotating system in this study. Ambiguous mode combinations can occur in this rotating system, and therefore, a method to overcome this ambiguity is proposed in this study. In addition, the specific phenomenon for a rotating system is introduced, and the effect of this phenomenon with regard to the obtained results through HHT is investigated.

  9. Redox potential of shallow groundwater by 1-month continuous in situ potentiometric measurements

    NASA Astrophysics Data System (ADS)

    Ioka, Seiichiro; Muraoka, Hirofumi; Suzuki, Yota

    2017-10-01

    One-month continuous in situ potentiometric measurements of redox potential (Eh) were used to investigate the dominant redox processes in the shallow groundwater (i.e., <10 m) of a Holocene aquifer, Aomori City, northern Japan. The Eh values, which were determined using a platinum electrode, were -163, -169 and -173 mV, respectively, for three monitoring campaigns. The temperatures and pH values of shallow groundwater during all three periods were approximately 12 °C and 6.6, respectively. Dissolved oxygen and sulfide ion concentrations were not detected. Chemical analyses showed that the shallow groundwater is Na-Fe-HCO3 type, and contains over 40 mg/L of Fe (the dominant cation) and over 200 mg/L of HCO3 - (the dominant anion). A good fit was found between measured Eh values and Eh values calculated using thermodynamic data of fine-grained goethite. This suggests that Fe redox system is related to the Eh values of shallow groundwater in the Aomori City aquifer.

  10. Autonomous Sensors for Measuring Continuously the Moisture and Salinity of a Porous Medium

    PubMed Central

    Chavanne, Xavier; Frangi, Jean-Pierre

    2017-01-01

    The article describes a new field sensor to monitor continuously in situ moisture and salinity of a porous medium via measurements of its dielectric permittivity, conductivity and temperature. It intends to overcome difficulties and biases encountered with sensors based on the same sensitivity principle. Permittivity and conductivity are determined simultaneously by a self-balanced bridge, which measures directly the admittance of sensor electrodes in medium. All electric biases are reduced and their residuals taken into account by a physical model of the instrument, calibrated against reference fluids. Geometry electrode is optimized to obtain a well representative sample of the medium. The sensor also permits acquiring a large amount of data at high frequency (six points every hour, and even more) and to access it rapidly, even in real time, owing to autonomy capabilities and wireless communication. Ongoing developments intend to simplify and standardize present sensors. Results of field trials of prototypes in different environments are presented. PMID:28492471

  11. Autonomous Sensors for Measuring Continuously the Moisture and Salinity of a Porous Medium.

    PubMed

    Chavanne, Xavier; Frangi, Jean-Pierre

    2017-05-11

    The article describes a new field sensor to monitor continuously in situ moisture and salinity of a porous medium via measurements of its dielectric permittivity, conductivity and temperature. It intends to overcome difficulties and biases encountered with sensors based on the same sensitivity principle. Permittivity and conductivity are determined simultaneously by a self-balanced bridge, which measures directly the admittance of sensor electrodes in medium. All electric biases are reduced and their residuals taken into account by a physical model of the instrument, calibrated against reference fluids. Geometry electrode is optimized to obtain a well representative sample of the medium. The sensor also permits acquiring a large amount of data at high frequency (six points every hour, and even more) and to access it rapidly, even in real time, owing to autonomy capabilities and wireless communication. Ongoing developments intend to simplify and standardize present sensors. Results of field trials of prototypes in different environments are presented.

  12. Society for Academic Continuing Medical Education Intervention Guideline Series: Guideline 1, Performance Measurement and Feedback.

    PubMed

    Van Hoof, Thomas J; Grant, Rachel E; Miller, Nicole E; Bell, Mary; Campbell, Craig; Colburn, Lois; Davis, David; Dorman, Todd; Horsley, Tanya; Jacobs-Halsey, Virginia; Kane, Gabrielle; LeBlanc, Constance; Lockyer, Jocelyn; Moore, Donald E; Morrow, Robert; Olson, Curtis A; Silver, Ivan; Thomas, David C; Kitto, Simon

    2015-01-01

    The Society for Academic Continuing Medical Education commissioned a study to clarify and, if possible, to standardize the terminology for a set of important educational interventions. In the form of a guideline, this article describes one such intervention, performance measurement and feedback, which is a common intervention in health professions education. In the form of a summary report, performance measurement and feedback is an opportunity for clinicians to view data about the care they provide compared with some standard and often with peer and benchmark comparisons. Based on a review of recent evidence and a facilitated discussion with the US and Canadian experts, we describe proper terminology for performance measurement and feedback and other important information about the intervention. We encourage leaders and researchers to consider and build on this guideline as they plan, implement, evaluate, and report efforts with performance measurement and feedback. Clear and consistent use of terminology is imperative, along with complete and accurate descriptions of interventions, to improve the use and study of performance measurement and feedback.

  13. Lithotomy versus jack-knife position on haemodynamic parameters assessed by impedance cardiography during anorectal surgery under low dose spinal anaesthesia: a randomized controlled trial.

    PubMed

    Borodiciene, Jurgita; Gudaityte, Jurate; Macas, Andrius

    2015-05-06

    Although the prone position providing better exposure for anorectal surgery is required it can cause a reduction of cardiac output and cardiac index. The goal was to compare haemodynamic changes assessed by impedance cardiography during anorectal surgery under low-dose spinal anaesthesia in lithotomy and jack-knife position. The prospective randomized controlled study included 104, ASA I-II adult patients admitted for elective minor anorectal surgery, assigned to be performed in lithotomy (groupL, n = 52) or jack-knife position (groupJ, n = 52). After arrival to operating room the standard monitoring, impedance cardiography device was connected to the patient, and the following variables were recorded: cardiac output, cardiac index, systemic vascular resistance, stroke index at times of arrival to operating room, placement for, start and end of surgery and placement to bed. Spinal block was made in the sitting position with 4 mg of 0.5% hyperbaric bupivacaine and 10 μg of Fentanyl injected over 2 min. Comparison was based on haemodynamic changes between and inside groups over time. Student's t, chi square tests were used for statistical analysis with p < 0.05 regarded as statistically significant. The reduction of cardiac output was statistically significant after placement of the patient into the prone position: from baseline 7.4+/-1.6 to 4.9+/-1.2 after placement for and 4.7+/-1.2 at the start and end of surgery (mean +/-SD l/min). The difference of cardiac output between groups was 2.0 l/min after positioning for and the start of surgery and 1.5 l/min at the end of surgery (p < 0.05). Mean cardiac index reduced from baseline 3.9+/-0.8 to 2.6+/-0.7 and 2.4+/-0.6 (mean+/-SD l/min/m(2)) in groupJ and between groups: by 1.0 l/min/m(2) after placement for, 1.1 at the start and 0.8 at the end of surgery (p < 0.05). Systemic vascular resistance increased from baseline 1080+/-338 to 1483+/-479 after placement for, 1523+/-481 at the start and 1525

  14. Continuous Wavelet Transform Analysis of Acceleration Signals Measured from a Wave Buoy

    PubMed Central

    Chuang, Laurence Zsu-Hsin; Wu, Li-Chung; Wang, Jong-Hao

    2013-01-01

    Accelerometers, which can be installed inside a floating platform on the sea, are among the most commonly used sensors for operational ocean wave measurements. To examine the non-stationary features of ocean waves, this study was conducted to derive a wavelet spectrum of ocean waves and to synthesize sea surface elevations from vertical acceleration signals of a wave buoy through the continuous wavelet transform theory. The short-time wave features can be revealed by simultaneously examining the wavelet spectrum and the synthetic sea surface elevations. The in situ wave signals were applied to verify the practicality of the wavelet-based algorithm. We confirm that the spectral leakage and the noise at very-low-frequency bins influenced the accuracies of the estimated wavelet spectrum and the synthetic sea surface elevations. The appropriate thresholds of these two factors were explored. To study the short-time wave features from the wave records, the acceleration signals recorded from an accelerometer inside a discus wave buoy are analysed. The results from the wavelet spectrum show the evidence of short-time nonlinear wave events. Our study also reveals that more surface profiles with higher vertical asymmetry can be found from short-time nonlinear wave with stronger harmonic spectral peak. Finally, we conclude that the algorithms of continuous wavelet transform are practical for revealing the short-time wave features of the buoy acceleration signals. PMID:23966188

  15. Performing and Interpreting Fractional Flow Reserve Measurements in Clinical Practice: An Expert Consensus Document

    PubMed Central

    Rudolph, Tanja; Rieber, Johannes; Eggebrecht, Holger; Richardt, Gert; Schmitz, Thomas; Werner, Nikos; Boenner, Florian; Möllmann, Helge

    2017-01-01

    Fractional flow reserve (FFR) measurements can determine the haemodynamic relevance of coronary artery stenoses. Current guidelines recommend their use in lesions in the absence of non-invasive proof of ischaemia. The prognostic impact of FFR has been evaluated in randomised trials, and it has been shown that revascularisation can be safely deferred if FFR is >0.80, while revascularisation of stenoses with FFR values ≤0.80 results in significantly lower event rates compared to medical treatment. Left main stenoses, aorto-ostial lesions, as well as patients with left ventricular hypertrophy and severely-impaired ejection fraction, have been excluded from large, randomised trials. While FFR measurements are relatively straightforward to perform, uncertainty about procedural logistics, as well as data acquisition and interpretation in specific situations, could explain why they are not widely used in clinical practice. We summarise the clinical data in support of FFR measurements, and provide recommendations for performing and interpreting the procedure. PMID:29588737

  16. Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for Column CO2 Measurements

    NASA Astrophysics Data System (ADS)

    Campbell, J. F.; Lin, B.; Nehrir, A. R.; Obland, M. D.; Liu, Z.; Browell, E. V.; Chen, S.; Kooi, S. A.; Fan, T. F.

    2015-12-01

    Global and regional atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission and Atmospheric Carbon and Transport (ACT) - America airborne investigation are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity-Modulated Continuous-Wave (IM-CW) lidar techniques are being investigated as a means of facilitating CO2 measurements from space and airborne platforms to meet the mission science measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud returns. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of intervening optically thin clouds, thereby minimizing bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the Earth's surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques and provides very high (at sub-meter level) range resolution. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. A comparison of BPSK and linear swept-frequency is also discussed in this paper. These techniques are used in a new data processing architecture to support the ASCENDS CarbonHawk Experiment Simulator (ACES) and ACT-America programs.

  17. Long-term stormwater quantity and quality analysis using continuous measurements in a French urban catchment.

    PubMed

    Sun, Siao; Barraud, Sylvie; Castebrunet, Hélène; Aubin, Jean-Baptiste; Marmonier, Pierre

    2015-11-15

    The assessment of urban stormwater quantity and quality is important for evaluating and controlling the impact of the stormwater to natural water and environment. This study mainly addresses long-term evolution of stormwater quantity and quality in a French urban catchment using continuous measured data from 2004 to 2011. Storm event-based data series are obtained (716 rainfall events and 521 runoff events are available) from measured continuous time series. The Mann-Kendall test is applied to these event-based data series for trend detection. A lack of trend is found in rainfall and an increasing trend in runoff is detected. As a result, an increasing trend is present in the runoff coefficient, likely due to growing imperviousness of the catchment caused by urbanization. The event mean concentration of the total suspended solid (TSS) in stormwater does not present a trend, whereas the event load of TSS has an increasing tendency, which is attributed to the increasing event runoff volume. Uncertainty analysis suggests that the major uncertainty in trend detection results lies in uncertainty due to available data. A lack of events due to missing data leads to dramatically increased uncertainty in trend detection results. In contrast, measurement uncertainty in time series data plays a trivial role. The intra-event distribution of TSS is studied based on both M(V) curves and pollutant concentrations of absolute runoff volumes. The trend detection test reveals no significant change in intra-event distributions of TSS in the studied catchment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. A simple condition for uniqueness of the absolutely continuous ergodic measure and its application to economic models

    NASA Astrophysics Data System (ADS)

    Sato, Kenji; Yano, Makoto

    2012-09-01

    Unique existence of the absolutely continuous ergodic measure, or existence of ergodic chaos (in a strong sense), has been considered important in economics since it explains the mechanism underlying economic fluctuations. In the present study, a simple sufficient condition for ergodic chaos is proved and applied to economic models.

  19. A decade of continuous NEE measurements at a Scottish peatland

    NASA Astrophysics Data System (ADS)

    Helfter, Carole; Campbell, Claire; Coyle, Mhairi; Anderson, Margaret; Drewer, Julia; Levy, Peter; Famulari, Daniela; Twigg, Marsailidh; Skiba, Ute; Billett, Michael; Dinsmore, Kerry; Nemitz, Eiko; Sutton, Mark

    2013-04-01

    Eddy-covariance measurements of carbon dioxide (CO2) fluxes have been running continuously at the Auchencorth Moss peatland site in Scotland (55o47'32N, 3o14'35W, 267 m a.s.l.) since the spring of 2002 which makes this study one of the longest ones to date on a peatland system. Auchencorth Moss is a low-lying, ombrotrophic peatland situated ca. 20 km south-west of Edinburgh. Peat depth ranges from <0.5 m to >0.5 m and the site has a mean annual precipitation of 1155 mm. The open moorland site has an extensive uniform fetch of blanket bog to the south, west and north. The vegetation present within the flux measurement footprint comprises mixed grass species, heather and substantial areas of moss species (Sphagnum spp. and Polytrichum spp.). The eddy-covariance system consists of a Licor 7000 closed-path infrared gas analyser operating at 10 Hz for the simultaneous measurement of carbon dioxide and water vapour and of a Gill Windmaster Pro ultrasonic anemometer, operating at 20 Hz, and mounted atop a 3 m mast. The effective measurement height is 3.5 m with a vertical separation of 20 cm between the anemometer and the inlet of the sampling line. Air is sampled at 20 litres per minute through a 40 m long Dekabon line (internal diameter 4 mm). In addition to eddy-covariance measurements, the site is equipped with a weather station, soil temperature measurements, total solar radiation and photosynthetically active radiation (PAR) sensors, a tipping bucket for rainfall and, since April 2007, water table depth has been recorded at half-hourly interval. On an annual basis, the peatland at Auchencorth Moss has consistently been a net sink of CO2 in the study period 2002-2012 with a mean net ecosystem exchange (NEE) of - 69.1 ± 33.6 g C-CO2 m-2 yr-1. This value is at the high end of other recent studies as is the inter-annual range of NEE (-31.4 to -135.9 g C-CO2 m-2 yr-1). Inter-annual variations in NEE are significant and strongly correlated to the length of the growing

  20. Continuous-Reading Cryogen Level Sensor

    NASA Technical Reports Server (NTRS)

    Barone, F. E.; Fox, E.; Macumber, S.

    1984-01-01

    Two pressure transducers used in system for measuring amount of cryogenic liquid in tank. System provides continuous measurements accurate within 0.03 percent. Sensors determine pressure in liquid and vapor in tank. Microprocessor uses pressure difference to compute mass of cryogenic liquid in tank. New system allows continuous sensing; unaffected by localized variations in composition and density as are capacitance-sensing schemes.

  1. Continuous measurements of water vapor isotopic compositions using an integrated cavity output spectrometer: calibrations and applications

    NASA Astrophysics Data System (ADS)

    Wang, L.; Caylor, K.; Dragoni, D.

    2009-04-01

    The 18O and 2H of water vapor can be used to investigate couplings between biological processes (e.g., photosynthesis or transpiration) and hydrologic processes (e.g., evaporation) and therefore serve as powerful tracers in hydrological cycles. A typical method for determining δ18O and δ2H fluxes in landscapes is a "Keeling Plot" approach, which uses field-collected vapor samples coupled with a traditional isotope ratio mass spectrometer to infer the isotopic composition of evapotranspiration. However, fractionation accompanying inefficient vapor trapping can lead to large measurement uncertainty and the intensive laboring involved in cold-trap make it almost impossible for continuous measurements. Over the last 3-4 years a few groups have developed continuous approaches for measuring δ18O and δ2H that use laser absorption spectroscopy (LAS) to achieve accuracy levels similar to lab-based mass spectrometry methods. Unfortunately, most LAS systems need cryogenic cooling, constant calibration to a reference gas, and substantial power requirements, which make them unsuitable for long-term field deployment at remote field sites. In this research, we tested out a new LAS-based water vapor isotope analyzer (WVIA, Los Gatos Research, Inc, Mountain View, CA) based on Integrated Cavity Output Spectroscopy (ICOS) and coupled this instrument with a flux gradient system. The WVIA was calibrated bi-weekly using a dew point generator and water with known δ18O and δ2H signatures. The field work was performed at Morgan-Monroe State Forest Ameriflux tower site (central Indiana) between August 8 and August 27, 2008. The combination method was able to produce hourly δ18O and δ2H fluxes data with reproducibility similar to lab-based mass spectrometry methods. Such high temporal resolution data were also able to capture signatures of canopy and bare soil evaporation to individual rainfall events. The use of the ICOS water vapor analyzer within a gradient system has the

  2. Poor agreement between continuous measurements of energy expenditure and routinely used prediction equations in intensive care unit patients.

    PubMed

    Reid, Clare L

    2007-10-01

    A wide variation in 24h energy expenditure has been demonstrated previously in intensive care unit (ICU) patients. The accuracy of equations used to predict energy expenditure in critically ill patients is frequently compared with single or short-duration indirect calorimetry measurements, which may not represent the total energy expenditure (TEE) of these patients. To take into account this variability in energy expenditure, estimates have been compared with continuous indirect calorimetry measurements. Continuous (24h/day for 5 days) indirect calorimetry measurements were made in patients requiring mechanical ventilation for 5 days. The Harris-Benedict, Schofield and Ireton-Jones equations and the American College of Chest Physicians recommendation of 25 kcal/kg/day were used to estimate energy requirements. A total of 192 days of measurements, in 27 patients, were available for comparison with the different equations. Agreement between the equations and measured values was poor. The Harris-Benedict, Schofield and ACCP equations provided more estimates (66%, 66% and 65%, respectively) within 80% and 110% of TEE values. However, each of these equations would have resulted in clinically significant underfeeding (<80% of TEE) in 16%, 15% and 22% of patients, respectively, and overfeeding (>110% of TEE) in 18%, 19% and 13% of patients, respectively. Limits of agreement between the different equations and TEE values were unacceptably wide. Prediction equations may result in significant under or overfeeding in the clinical setting.

  3. 40 CFR 1065.150 - Continuous sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Continuous sampling. 1065.150 Section... ENGINE-TESTING PROCEDURES Equipment Specifications § 1065.150 Continuous sampling. You may use continuous sampling techniques for measurements that involve raw or dilute sampling. Make sure continuous sampling...

  4. 40 CFR 1065.150 - Continuous sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Continuous sampling. 1065.150 Section... ENGINE-TESTING PROCEDURES Equipment Specifications § 1065.150 Continuous sampling. You may use continuous sampling techniques for measurements that involve raw or dilute sampling. Make sure continuous sampling...

  5. Measuring maternal satisfaction with maternity care: A systematic integrative review: What is the most appropriate, reliable and valid tool that can be used to measure maternal satisfaction with continuity of maternity care?

    PubMed

    Perriman, Noelyn; Davis, Deborah

    2016-06-01

    The objective of this systematic integrative review is to identify, summarise and communicate the findings of research relating to tools that measure maternal satisfaction with continuity of maternity care models. In so doing the most appropriate, reliable and valid tool that can be used to measure maternal satisfaction with continuity of maternity care will be determined. A systematic integrative review of published and unpublished literature was undertaken using selected databases. Research papers were included if they measured maternal satisfaction in a continuity model of maternity care, were published in English after 1999 and if they included (or made available) the instrument used to measure satisfaction. Six hundred and thirty two unique papers were identified and after applying the selection criteria, four papers were included in the review. Three of these originated in Australia and one in Canada. The primary focus of all papers was not on the development of a tool to measure maternal satisfaction but on the comparison of outcomes in different models of care. The instruments developed varied in terms of the degree to which they were tested for validity and reliability. Women's satisfaction with maternity services is an important measure of quality. Most satisfaction surveys in maternity appear to reflect fragmented models of care though continuity of care models are increasing in line with the evidence demonstrating their effectiveness. It is important that robust tools are developed for this context and that there is some consistency in the way this is measured and reported for the purposes of benchmarking and quality improvement. Copyright © 2016 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  6. A geometric approach to aortic root surgical anatomy.

    PubMed

    Contino, Monica; Mangini, Andrea; Lemma, Massimo Giovanni; Romagnoni, Claudia; Zerbi, Pietro; Gelpi, Guido; Antona, Carlo

    2016-01-01

    The aim of this study was the analysis of the geometrical relationships between the different structures constituting the aortic root, with particular attention to interleaflet triangles, haemodynamic ventriculo-arterial junction and functional aortic annulus in normal subjects. Sixteen formol-fixed human hearts with normal aortic roots were studied. The aortic root was isolated, sectioned at the midpoint of the non-coronary sinus, spread apart and photographed by a high-resolution digital camera. After calibration and picture resizing, the software AutoCAD 2004 was used to identify and measure all the elements of the interleaflets triangles and of the aortic root that were objects of our analysis. Multiple comparisons were performed with one-way analysis of variance for continuous data and with Kruskal-Wallis analysis for non-continuous data. Linear regression and Pearson's product correlation were used to correlate root element dimensions when appropriate. Student's t-test was used to compare means for unpaired data. Heron's formula was applied to estimate the functional aortic annular diameters. The non coronary-left coronary interleaflets triangles were larger, followed by inter-coronary and right-non-coronary ones. The apical angle is <60° and its standard deviation can be considered an asymmetry index. The sinu-tubular junction was shown to be 10% larger than the virtual basal ring (VBR). The mathematical relationship between the haemodynamic ventriculo-arterial junction and the VBR calculated by linear regression and expressed in terms of the diameter was: haemodynamic ventriculo-arterial junction = 2.29 VBR (diameter) + 47. Conservative aortic surgery is based on a better understanding of aortic root anatomy and physiology. The relationships among its elements are of paramount importance during aortic valve repair/sparing procedures and they can be useful also in echocardiographic analysis and in computed tomography reconstruction. © The Author 2015

  7. Addressing continuous data measured with different instruments for participants excluded from trial analysis: a guide for systematic reviewers.

    PubMed

    Ebrahim, Shanil; Johnston, Bradley C; Akl, Elie A; Mustafa, Reem A; Sun, Xin; Walter, Stephen D; Heels-Ansdell, Diane; Alonso-Coello, Pablo; Guyatt, Gordon H

    2014-05-01

    We previously developed an approach to address the impact of missing participant data in meta-analyses of continuous variables in trials that used the same measurement instrument. We extend this approach to meta-analyses including trials that use different instruments to measure the same construct. We reviewed the available literature, conducted an iterative consultative process, and developed an approach involving a complete-case analysis complemented by sensitivity analyses that apply a series of increasingly stringent assumptions about results in patients with missing continuous outcome data. Our approach involves choosing the reference measurement instrument; converting scores from different instruments to the units of the reference instrument; developing four successively more stringent imputation strategies for addressing missing participant data; calculating a pooled mean difference for the complete-case analysis and imputation strategies; calculating the proportion of patients who experienced an important treatment effect; and judging the impact of the imputation strategies on the confidence in the estimate of effect. We applied our approach to an example systematic review of respiratory rehabilitation for chronic obstructive pulmonary disease. Our extended approach provides quantitative guidance for addressing missing participant data in systematic reviews of trials using different instruments to measure the same construct. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Acoustic mode measurements in the inlet of a model turbofan using a continuously rotating rake

    NASA Astrophysics Data System (ADS)

    Heidelberg, Laurence J.; Hall, David G.

    1993-01-01

    Comprehensive measurements of the spinning acoustic mode structure in the inlet of the Advanced Ducted Propeller (ADP) have been completed. These measurements were taken using a unique and previously untried method which was first proposed by T.G. Sofrin. A continuously rotating microphone system was employed. The ADP model was designed and built by Pratt & Whitney and tested in the NASA Lewis 9- by 15-foot Anechoic Wind Tunnel. Three inlet configurations were tested with cut-on and cutoff stator vane sets. The cutoff stator was designed to suppress all modes at the blade passing frequency. Rotating rake measurements indicate that several extraneous circumferential modes were active. The mode orders suggest that their source was an interaction between the rotor and small interruptions in the casing tip treatment. The cut-on stator produced the expected circumferential modes plus higher levels of the unexpected modes seen with the cutoff stator.

  9. Acoustic Mode Measurements in the Inlet of a Model Turbofan Using a Continuously Rotating Rake

    NASA Technical Reports Server (NTRS)

    Heidelberg, Laurence J.; Hall, David G.

    1992-01-01

    Comprehensive measurements of the spinning acoustic mode structure in the inlet of the Advanced Ducted Propeller (ADP) have been completed. These measurements were taken using a unique and previously untried method which was first proposed by T.G. Sofrin. A continuously rotating microphone system was employed. The ADP model was designed and built by Pratt & Whitney and tested in the NASA Lewis 9- by 15-foot Anechoic Wind Tunnel. Three inlet configurations were tested with cut-on and cutoff stator vane sets. The cutoff stator was designed to suppress all modes at the blade passing frequency. Rotating rake measurements indicate that several extraneous circumferential modes were active. The mode orders suggest that their source was an interaction between the rotor and small interruptions in the casing tip treatment. The cut-on stator produced the expected circumferential modes plus higher levels of the unexpected modes seen with the cutoff stator.

  10. Severe community-acquired pneumonia: timely management measures in the first 24 hours.

    PubMed

    Phua, Jason; Dean, Nathan C; Guo, Qi; Kuan, Win Sen; Lim, Hui Fang; Lim, Tow Keang

    2016-08-28

    Mortality rates for severe community-acquired pneumonia (CAP) range from 17 to 48 % in published studies.In this review, we searched PubMed for relevant papers published between 1981 and June 2016 and relevant files. We explored how early and aggressive management measures, implemented within 24 hours of recognition of severe CAP and carried out both in the emergency department and in the ICU, decrease mortality in severe CAP.These measures begin with the use of severity assessment tools and the application of care bundles via clinical decision support tools. The bundles include early guideline-concordant antibiotics including macrolides, early haemodynamic support (lactate measurement, intravenous fluids, and vasopressors), and early respiratory support (high-flow nasal cannulae, lung-protective ventilation, prone positioning, and neuromuscular blockade for acute respiratory distress syndrome).While the proposed interventions appear straightforward, multiple barriers to their implementation exist. To successfully decrease mortality for severe CAP, early and close collaboration between emergency medicine and respiratory and critical care medicine teams is required. We propose a workflow incorporating these interventions.

  11. Non-invasive assessment of vasospasm following aneurysmal SAH using C-arm FDCT parenchymal blood volume measurement in the neuro-interventional suite: Technical feasibility

    PubMed Central

    Downer, Jonathan; Corkill, Rufus; Byrne, James V

    2015-01-01

    Introduction Cerebral vasospasm is the leading cause of morbidity and mortality in patients with aneurysmal subarachnoid haemorrhage (SAH) surviving the initial ictus. Commonly used techniques for vasospasm assessment are digital subtraction angiography and transcranial Doppler sonography. These techniques can reliably identify only the major vessel spasm and fail to estimate its haemodynamic significance. To overcome these issues and to enable comprehensive non-invasive assessment of vasospasm inside the interventional suite, a novel protocol involving measurement of parenchymal blood volume (PBV) using C-arm flat detector computed tomography (FDCT) was implemented. Materials and methods Patients from the neuro-intensive treatment unit (ITU) with suspected vasospasm following aneurysmal SAH were scanned with a biplane C-arm angiography system using an intravenous contrast injection protocol. The PBV maps were generated using prototype software. Contemporaneous clinically indicated MR scan including the diffusion- and perfusion-weighted sequences was performed. C-arm PBV maps were compared against the MR perfusion maps. Results Distribution of haemodynamic impairment on C-arm PBV maps closely matched the pattern of abnormality on MR perfusion maps. On visual comparison between the two techniques, the extent of abnormality indicated PBV to be both cerebral blood flow and cerebral blood volume weighted. Conclusion C-arm FDCT PBV measurements allow an objective assessment of the severity and localisation of cerebral hypoperfusion resulting from vasospasm. The technique has proved feasible and useful in very sick patients after aneurysmal SAH. The promise shown in this early study indicates that it deserves further evaluation both for post-SAH vasospasm and in other relevant clinical settings. PMID:26017197

  12. Non-invasive assessment of vasospasm following aneurysmal SAH using C-arm FDCT parenchymal blood volume measurement in the neuro-interventional suite: Technical feasibility.

    PubMed

    Kamran, Mudassar; Downer, Jonathan; Corkill, Rufus; Byrne, James V

    2015-08-01

    Cerebral vasospasm is the leading cause of morbidity and mortality in patients with aneurysmal subarachnoid haemorrhage (SAH) surviving the initial ictus. Commonly used techniques for vasospasm assessment are digital subtraction angiography and transcranial Doppler sonography. These techniques can reliably identify only the major vessel spasm and fail to estimate its haemodynamic significance. To overcome these issues and to enable comprehensive non-invasive assessment of vasospasm inside the interventional suite, a novel protocol involving measurement of parenchymal blood volume (PBV) using C-arm flat detector computed tomography (FDCT) was implemented. Patients from the neuro-intensive treatment unit (ITU) with suspected vasospasm following aneurysmal SAH were scanned with a biplane C-arm angiography system using an intravenous contrast injection protocol. The PBV maps were generated using prototype software. Contemporaneous clinically indicated MR scan including the diffusion- and perfusion-weighted sequences was performed. C-arm PBV maps were compared against the MR perfusion maps. Distribution of haemodynamic impairment on C-arm PBV maps closely matched the pattern of abnormality on MR perfusion maps. On visual comparison between the two techniques, the extent of abnormality indicated PBV to be both cerebral blood flow and cerebral blood volume weighted. C-arm FDCT PBV measurements allow an objective assessment of the severity and localisation of cerebral hypoperfusion resulting from vasospasm. The technique has proved feasible and useful in very sick patients after aneurysmal SAH. The promise shown in this early study indicates that it deserves further evaluation both for post-SAH vasospasm and in other relevant clinical settings. © The Author(s) 2015.

  13. Continuous long-term measurements of the middle ear pressure in subjects without a history of ear disease.

    PubMed

    Tideholm, B; Carlborg, B; Jönsson, S; Bylander-Groth, A

    1998-06-01

    A new method was used for continuous measurement of the middle ear (ME) pressure during a 24-h period. In 10 subjects without a history of ear disease a small perforation was made through the tympanic membrane. A tight rubber stopper containing a small polyethylene tube was fitted into the external ear canal. Conventional tubal function tests were performed. The equipment was then carried by the subjects for 24 h of normal activity to monitor any slow or rapid dynamic pressure change in the ME. Body position was found to be the most important factor affecting ME pressure variation, during the 24-h continuous pressure measurements. A significant pressure rise occurred in the recumbent position in all but one subject. Few rapid pressure equilibrations were seen during the recordings, indicating few tubal openings. This implies that the pressure changes in the ME seen in this study were mainly the result of gas exchange over the mucosa. The investigation might be a base for reference when investigating different kinds of pathologic conditions in the ear.

  14. Pulsed EMAT (Electromagnetic Acoustic Transducer) acoustic measurements on a horizontal continuous caster for internal temperature determination

    NASA Astrophysics Data System (ADS)

    Boyd, Donald M.

    1989-10-01

    Development of a Pulsed Electromagnetic Acoustic Transducer (EMAT) through transmission system for acoustic measurements on steel billets up to 1300 C was completed. Laboratory measurements of acoustic velocity were made, and used to determine the average internal temperature of hot stainless and carbon steel billets. Following the success of the laboratory system development, the laboratory EMAT system was subsequently tested successfully at the Baltimore Specialty Steel Co. on a horizontal continuous caster. Details of the sensor system development and the steel plant demonstration results are presented. Future directions for the high temperature pulsed EMAT internal temperature concept are discussed for potential material processing applications.

  15. Practical performance of real-time shot-noise measurement in continuous-variable quantum key distribution

    NASA Astrophysics Data System (ADS)

    Wang, Tao; Huang, Peng; Zhou, Yingming; Liu, Weiqi; Zeng, Guihua

    2018-01-01

    In a practical continuous-variable quantum key distribution (CVQKD) system, real-time shot-noise measurement (RTSNM) is an essential procedure for preventing the eavesdropper exploiting the practical security loopholes. However, the performance of this procedure itself is not analyzed under the real-world condition. Therefore, we indicate the RTSNM practical performance and investigate its effects on the CVQKD system. In particular, due to the finite-size effect, the shot-noise measurement at the receiver's side may decrease the precision of parameter estimation and consequently result in a tight security bound. To mitigate that, we optimize the block size for RTSNM under the ensemble size limitation to maximize the secure key rate. Moreover, the effect of finite dynamics of amplitude modulator in this scheme is studied and its mitigation method is also proposed. Our work indicates the practical performance of RTSNM and provides the real secret key rate under it.

  16. Finite-size analysis of continuous-variable measurement-device-independent quantum key distribution

    NASA Astrophysics Data System (ADS)

    Zhang, Xueying; Zhang, Yichen; Zhao, Yijia; Wang, Xiangyu; Yu, Song; Guo, Hong

    2017-10-01

    We study the impact of the finite-size effect on the continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol, mainly considering the finite-size effect on the parameter estimation procedure. The central-limit theorem and maximum likelihood estimation theorem are used to estimate the parameters. We also analyze the relationship between the number of exchanged signals and the optimal modulation variance in the protocol. It is proved that when Charlie's position is close to Bob, the CV-MDI QKD protocol has the farthest transmission distance in the finite-size scenario. Finally, we discuss the impact of finite-size effects related to the practical detection in the CV-MDI QKD protocol. The overall results indicate that the finite-size effect has a great influence on the secret-key rate of the CV-MDI QKD protocol and should not be ignored.

  17. Advanced intensity-modulation continuous-wave lidar techniques for ASCENDS CO2 column measurements

    NASA Astrophysics Data System (ADS)

    Campbell, Joel F.; Lin, Bing; Nehrir, Amin R.; Harrison, F. W.; Obland, Michael D.; Meadows, Byron

    2015-10-01

    Global atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity- Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space to meet the ASCENDS measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud contamination. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating the need to correct for sidelobe bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. A comparison of BPSK and linear swept-frequency is also discussed in this paper. These results are extended to include Richardson-Lucy deconvolution techniques to extend the resolution of the lidar beyond that implied by limit of the bandwidth of the modulation, where it is shown useful for making tree canopy measurements.

  18. Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for ASCENDS O2 Column Measurements

    NASA Technical Reports Server (NTRS)

    Campbell, Joel F.; Lin, Bing; Nehrir, Amin R.; Harrison, F. Wallace; Obland, Michael D.; Meadows, Byron

    2015-01-01

    Global atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity- Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space to meet the ASCENDS measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud contamination. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating the need to correct for sidelobe bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. A comparison of BPSK and linear swept-frequency is also discussed in this paper. These results are extended to include Richardson-Lucy deconvolution techniques to extend the resolution of the lidar beyond that implied by limit of the bandwidth of the modulation, where it is shown useful for making tree canopy measurements.

  19. Comparing Measures of Voice Quality from Sustained Phonation and Continuous Speech

    ERIC Educational Resources Information Center

    Gerratt, Bruce R.; Kreiman, Jody; Garellek, Marc

    2016-01-01

    Purpose: The question of what type of utterance--a sustained vowel or continuous speech--is best for voice quality analysis has been extensively studied but with equivocal results. This study examines whether previously reported differences derive from the articulatory and prosodic factors occurring in continuous speech versus sustained phonation.…

  20. Thermal dissociation cavity attenuated phase shift spectroscopy for continuous measurement of total peroxy and organic nitrates in the clean atmosphere

    NASA Astrophysics Data System (ADS)

    Sadanaga, Yasuhiro; Takaji, Ryo; Ishiyama, Ayana; Nakajima, Kazuo; Matsuki, Atsushi; Bandow, Hiroshi

    2016-07-01

    A thermal dissociation cavity attenuated phase shift spectroscopy (TD-CAPS) instrument was developed for measuring total peroxy nitrates (PNs) and organic nitrates (ONs) concentrations in the clean atmosphere. This instrument is easy to operate and can be applied to continuous measurement of PNs and ONs. A continuously measurable system is convenient to perform observations, especially in remote areas. Three lines (NO2, PNs, and ONs lines) were used for thermal dissociation. The NO2 line contains a quartz tube that is not heated, while the PN and ON lines contain quartz tubes that are heated at 433 K and 633 K, respectively. The concentrations of NO2, NO2 + PNs, and NO2 + PNs + ONs can be obtained from the NO2, PN, and ON lines, respectively. The lower limit values of the detection limit (3σ) for PNs and ONs were estimated to be 21 parts per trillion by volume with an integration time of 2 min. PNs were selectively thermally decomposed in the PNs line and formed NO2 quantitatively. In the ONs line, both PNs and ONs were thermally decomposed to produce NO2 quantitatively, but partial decomposition of HNO3 at 633 K interfered with the ONs measurement. Therefore, a HNO3 scrubber is required before the ONs line. Continuous observations were conducted with the TD-CAPS instrument in a remote area, and the instrument performed well for obtaining PNs and ONs concentrations.

  1. Intensity Modulation Techniques for Continuous-Wave Lidar for Column CO2 Measurements

    NASA Astrophysics Data System (ADS)

    Campbell, J. F.; Lin, B.; Obland, M. D.; Kooi, S. A.; Fan, T. F.; Meadows, B.; Browell, E. V.; Erxleben, W. H.; McGregor, D.; Dobler, J. T.; Pal, S.; O'Dell, C.

    2017-12-01

    Global and regional atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission and the Atmospheric Carbon and Transport (ACT) - America project are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity-Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space and airborne platforms to meet the ASCENDS and ACT-America science measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) and Linear Swept Frequency modulations to uniquely discriminate surface lidar returns from intermediate aerosol and cloud returns. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that take advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques and provides very high (at sub-meter level) range resolution. We compare BPSK to linear swept frequency and introduce a new technique to eliminate sidelobes in situations from linear swept frequency where the SNR is high with results that rival BPSK. We also investigate the effects of non-linear modulators, which can in some circumstances degrade the orthogonality of the waveforms, and show how to avoid this. These techniques are used in a new data processing architecture written in

  2. Tropospheric ozone reduces carbon assimilation in trees: estimates from analysis of continuous flux measurements.

    PubMed

    Fares, Silvano; Vargas, Rodrigo; Detto, Matteo; Goldstein, Allen H; Karlik, John; Paoletti, Elena; Vitale, Marcello

    2013-08-01

    High ground-level ozone concentrations are typical of Mediterranean climates. Plant exposure to this oxidant is known to reduce carbon assimilation. Ozone damage has been traditionally measured through manipulative experiments that do not consider long-term exposure and propagate large uncertainty by up-scaling leaf-level observations to ecosystem-level interpretations. We analyzed long-term continuous measurements (>9 site-years at 30 min resolution) of environmental and eco-physiological parameters at three Mediterranean ecosystems: (i) forest site dominated by Pinus ponderosa in the Sierra Mountains in California, USA; (ii) forest site composed of a mixture of Quercus spp. and P. pinea in the Tyrrhenian sea coast near Rome, Italy; and (iii) orchard site of Citrus sinensis cultivated in the California Central Valley, USA. We hypothesized that higher levels of ozone concentration in the atmosphere result in a decrease in carbon assimilation by trees under field conditions. This hypothesis was tested using time series analysis such as wavelet coherence and spectral Granger causality, and complemented with multivariate linear and nonlinear statistical analyses. We found that reduction in carbon assimilation was more related to stomatal ozone deposition than to ozone concentration. The negative effects of ozone occurred within a day of exposure/uptake. Decoupling between carbon assimilation and stomatal aperture increased with the amount of ozone pollution. Up to 12-19% of the carbon assimilation reduction in P. ponderosa and in the Citrus plantation was explained by higher stomatal ozone deposition. In contrast, the Italian site did not show reductions in gross primary productivity either by ozone concentration or stomatal ozone deposition, mainly due to the lower ozone concentrations in the periurban site over the shorter period of investigation. These results highlight the importance of plant adaptation/sensitivity under field conditions, and the importance of

  3. Mercury Emission Measurement in Coal-Fired Boilers by Continuous Mercury Monitor and Ontario Hydro Method

    NASA Astrophysics Data System (ADS)

    Zhu, Yanqun; Zhou, Jinsong; He, Sheng; Cai, Xiaoshu; Hu, Changxin; Zheng, Jianming; Zhang, Le; Luo, Zhongyang; Cen, Kefa

    2007-06-01

    The mercury emission control approach attaches more importance. The accurate measurement of mercury speciation is a first step. Because OH method (accepted method) can't provide the real-time data and 2-week time for results attained, it's high time to seek on line mercury continuous emission monitors(Hg-CEM). Firstly, the gaseous elemental and oxidized mercury were conducted to measure using OH and CEM method under normal operation conditions of PC boiler after ESP, the results between two methods show good consistency. Secondly, through ESP, gaseous oxidized mercury decrease a little and particulate mercury reduce a little bit, but the elemental mercury is just the opposite. Besides, the WFGD system achieved to gaseous oxidized mercury removal of 53.4%, gaseous overall mercury and elemental mercury are 37.1% and 22.1%, respectively.

  4. Optical frequency modulation continuous wave coherent laser radar for spacecraft safe landing vector velocity measurement

    NASA Astrophysics Data System (ADS)

    Sui, Xiao-lin; Zhou, Shou-huan

    2013-05-01

    The design and performance of Optical frequency modulation continuous wave (OFMCW) coherent laser radar is presented. By employing a combination of optical heterodyne and linear frequency modulation techniques and utilizing fiber optic technologies, highly efficient, compact and reliable laser radar suitable for operation in a space environment is being developed.We also give a hardware structure of the OFMCW coherent laser radar. We made a detailed analysis of the measurement error. Its accuracy in the speed range is less than 0.5%.Measurement results for the movement of the carrier has also made a detailed assessment. The results show that its acceleration vector has better adaptability. The circuit structure is also given a detailed design. At the end of the article, we give the actual authentication method and experimental results.

  5. Ten good reasons why everybody can and should perform cardiac ultrasound in the ICU.

    PubMed

    Charron, Cyril; Repessé, Xavier; Bodson, Laurent; Au, Siu-Ming; Vieillard-Baron, Antoine

    2014-01-01

    Critical care ultrasonography (CCUS) has been defined as an ultrasound evaluation of the heart, abdomen, pleura and lungs at the bedside by the intensivist, 24/7. Within CCUS, critical care echocardiography (CCE) is used to assess cardiac function and more generally haemodynamics. Experts in haemodynamics have published a 'consensus of 16' regarding an update on haemodynamic monitoring. They reported the ten key properties of an 'ideal' haemodynamic monitoring system, which perfectly match the ten good reasons we describe here for performing CCE in critically ill patients. Even though unfortunately no evidence-based medicine study is available to support this review, especially regarding CCE-related improvement of outcome, many clinical studies have demonstrated that CCE provides measurements of relevant, accurate, reproducible and interpretable variables, is easy to use, readily available, has a rapid response time, causes no harm, and is cost-effective. Whether it is operator-independent is obviously more debatable and is discussed in this review. All these characteristics are arguments for the extensive use of CCE by intensivists. This is why experts in the field have recommended that a basic level of CCE should be included in the training of all intensivists.

  6. Continuous measurement of suspended-sediment discharge in rivers by use of optical backscatterance sensors

    USGS Publications Warehouse

    Schoellhamer, D.H.; Wright, S.A.; Bogen, J.; Fergus, T.; Walling, D.

    2003-01-01

    Optical sensors have been used to measure turbidity and suspended-sediment concentration by many marine and estuarine studies, and optical sensors can provide automated, continuous time series of suspended-sediment concentration and discharge in rivers. Three potential problems with using optical sensors are biological fouling, particle-size variability, and particle-reflectivity variability. Despite varying particle size, output from an optical backscatterance sensor in the Sacramento River at Freeport, California, USA, was calibrated successfully to discharge-weighted, cross-sectionally averaged suspended-sediment concentration, which was measured with the equal discharge-, or width-increment, methods and an isokinetic sampler. A correction for sensor drift was applied to the 3-year time series. However, the calibration of an optical backscatterance sensor used in the Colorado River at Cisco, Utah, USA, was affected by particle-size variability. The adjusted time series at Freeport was used to calculate hourly suspended-sediment discharge that compared well with daily values from a sediment station at Freeport. The appropriateness of using optical sensors in rivers should be evaluated on a site-specific basis and measurement objectives, potential particle size effects, and potential fouling should be considered.

  7. Continuous metabolic and cardiovascular measurements on a monkey subject during a simulated 6-day Spacelab mission

    NASA Technical Reports Server (NTRS)

    Pace, N.; Rahlmann, D. F.; Mains, R. C.; Kodama, A. M.; Mccutcheon, E. P.

    1979-01-01

    A 10-kg male pig-tailed monkey (Macaca nemestrina) was selected as an optimal species for spaceflight studies on weightlessness. Three days before the simulated launch, the animal was placed in a fiberglass pod system to provide continuous measurement of respiratory gas exchange. Attention is given to examining the effects of weightlessness on several basic parameters of metabolic and cardiovascular function in an adult nonhuman primate. The 10.7-day total simulated-experiment period consisted of preflight 2.6 days, inflight 6.3 days, and postflight 1.8 days. Statistically significant diurnal variation was noted in oxygen consumption and CO2 production rates, body temperature and HR, but not in respiratory quotient or blood pressure. The high quality of the continuous data obtained demonstrates the feasibility of performing sound physiological experimentation on nonhuman primates in the Spacelab environment.

  8. Evaluation of treatment-effect heterogeneity using biomarkers measured on a continuous scale: subpopulation treatment effect pattern plot.

    PubMed

    Lazar, Ann A; Cole, Bernard F; Bonetti, Marco; Gelber, Richard D

    2010-10-10

    The discovery of biomarkers that predict treatment effectiveness has great potential for improving medical care, particularly in oncology. These biomarkers are increasingly reported on a continuous scale, allowing investigators to explore how treatment efficacy varies as the biomarker values continuously increase, as opposed to using arbitrary categories of expression levels resulting in a loss of information. In the age of biomarkers as continuous predictors (eg, expression level percentage rather than positive v negative), alternatives to such dichotomized analyses are needed. The purpose of this article is to provide an overview of an intuitive statistical approach-the subpopulation treatment effect pattern plot (STEPP)-for evaluating treatment-effect heterogeneity when a biomarker is measured on a continuous scale. STEPP graphically explores the patterns of treatment effect across overlapping intervals of the biomarker values. As an example, STEPP methodology is used to explore patterns of treatment effect for varying levels of the biomarker Ki-67 in the BIG (Breast International Group) 1-98 randomized clinical trial comparing letrozole with tamoxifen as adjuvant therapy for postmenopausal women with hormone receptor-positive breast cancer. STEPP analyses showed patients with higher Ki-67 values who were assigned to receive tamoxifen had the poorest prognosis and may benefit most from letrozole.

  9. First density profile measurements using frequency modulation of the continuous wave reflectometry on JETa)

    NASA Astrophysics Data System (ADS)

    Meneses, L.; Cupido, L.; Sirinelli, A.; Manso, M. E.; Jet-Efds Contributors

    2008-10-01

    We present the main design options and implementation of an X-mode reflectometer developed and successfully installed at JET using an innovative approach. It aims to prove the viability of measuring density profiles with high spatial and temporal resolution using broadband reflectometry operating in long and complex transmission lines. It probes the plasma with magnetic fields between 2.4 and 3.0 T using the V band [~(0-1.4)×1019 m-3]. The first experimental results show the high sensitivity of the diagnostic when measuring changes in the plasma density profile occurring ITER relevant regimes, such as ELMy H-modes. The successful demonstration of this concept motivated the upgrade of the JET frequency modulation of the continuous wave (FMCW) reflectometry diagnostic, to probe both the edge and core. This new system is essential to prove the viability of using the FMCW reflectometry technique to probe the plasma in next step devices, such as ITER, since they share the same waveguide complexity.

  10. An automated system for performing continuous viscosity versus temperature measurements of fluids using an Ostwald viscometer

    NASA Astrophysics Data System (ADS)

    Beaulieu, L. Y.; Logan, E. R.; Gering, K. L.; Dahn, J. R.

    2017-09-01

    An automated system was developed to measure the viscosity of fluids as a function of temperature using image analysis tracking software. An Ostwald viscometer was placed in a three-wall dewar in which ethylene glycol was circulated using a thermal bath. The system collected continuous measurements during both heating and cooling cycles exhibiting no hysteresis. The use of video tracking analysis software greatly reduced the measurement errors associated with measuring the time required for the meniscus to pass through the markings on the viscometer. The stability of the system was assessed by performing 38 consecutive measurements of water at 42.50 ± 0.05 °C giving an average flow time of 87.7 ± 0.3 s. A device was also implemented to repeatedly deliver a constant volume of liquid of 11.00 ± 0.03 ml leading to an average error in the viscosity of 0.04%. As an application, the system was used to measure the viscosity of two Li-ion battery electrolyte solvents from approximately 10 to 40 °C with results showing excellent agreement with viscosity values calculated using Gering's Advanced Electrolyte Model (AEM).

  11. A novel method of continuous measurement of head of bed elevation in ventilated patients.

    PubMed

    Balonov, Konstantin; Miller, Andrew D; Lisbon, Alan; Kaynar, A Murat

    2007-06-01

    We developed a novel pressure transducer-based method of continuous measurement of head of bed elevation. Following validation of the method we hypothesized that head of bed angles would be at or above 30 degrees among mechanically ventilated patients throughout the day due to a hospital-wide initiative on ventilator-associated pneumonia prevention and standardized electronic order entry system to keep head of bed at an angle of 30 degrees or greater. Prospective observational study in university hospital intensive care units. Twenty-nine consecutive mechanically ventilated patients with no contraindications for semirecumbency. We acquired 113 pairs of measurements on unused beds for validation of the method at angles between 3 degrees and 70 degrees. Correlation between transducer and protractor was fitted into a linear regression model (R2 = 0.98) with minimal variation of data along the line of equality. Bland-Altman analysis showed a mean difference of 1.6 degrees +/- 1.6 degrees. Ninety-six percent of differences were within 2 SD from the mean. This method was then used among 29 intubated patients to collect head of bed data over a 24-h period for 3 consecutive days. Contrary to our hypothesis, all patients had head of bed angles less than 30 degrees. Our results suggest that this method could be used with high reliability and patients in our institution were not kept even at 30 degrees. The results are in accord with those of a recent study which found that continued maintenance of previously suggested head of bed angles was difficult to attain clinically. This may lead us to reevaluate methods studying the impact of head of bed elevation in VAP prevention.

  12. High Precision Continuous and Real-Time Measurement of Atmospheric Oxygen Using Cavity Ring-Down Spectroscopy.

    NASA Astrophysics Data System (ADS)

    Kim-Hak, D.; Hoffnagle, J.; Rella, C.; Sun, M.

    2016-12-01

    Oxygen is a major and vital component of the Earth atmosphere representing about 21% of its composition. It is consumed or produced through biochemical processes such as combustion, respiration, and photosynthesis. Although atmospheric oxygen is not a greenhouse gas, it can be used as a top-down constraint on the carbon cycle. The variation observations of oxygen in the atmosphere are very small, in the order of the few ppm's. This presents the main technical challenge for measurement as a very high level of precision is required and only few methods including mass spectrometry, fuel cell, and paramagnetic are capable of overcoming it. Here we present new developments of a high-precision gas analyzer that utilizes the technique of Cavity Ring-Down Spectroscopy to measure oxygen concentration and oxygen isotope. Its compact and ruggedness design combined with high precision and long-term stability allows the user to deploy the instrument in the field for continuous monitoring of atmospheric oxygen level. Measurements have a 1-σ 5-minute averaging precision of 1-2 ppm for O2 over a dynamic range of 0-20%. We will present supplemental data acquired from our 10m tower measurements in Santa Clara, CA.

  13. Reliability of laser Doppler, near-infrared spectroscopy and Doppler ultrasound for peripheral blood flow measurements during and after exercise in the heat.

    PubMed

    Choo, Hui C; Nosaka, Kazunori; Peiffer, Jeremiah J; Ihsan, Mohammed; Yeo, Chow C; Abbiss, Chris R

    2017-09-01

    This study examined the test-retest reliability of near-infrared spectroscopy (NIRS), laser Doppler flowmetry (LDF) and Doppler ultrasound to assess exercise-induced haemodynamics. Nine men completed two identical trials consisting of 25-min submaximal cycling at first ventilatory threshold followed by repeated 30-s bouts of high-intensity (90% of peak power) cycling in 32.8 ± 0.4°C and 32 ± 5% relative humidity (RH). NIRS (tissue oxygenation index [TOI] and total haemoglobin [tHb]) and LDF (perfusion units [PU]) signals were monitored continuously during exercise, and leg blood flow was assessed by Doppler ultrasound at baseline and after exercise. Cutaneous vascular conductance (CVC; PU/mean arterial pressure (MAP)) was expressed as the percentage change from baseline (%CVC BL ). Coefficients of variation (CVs) as indicators of absolute reliability were 18.7-28.4%, 20.2-33.1%, 42.5-59.8%, 7.8-12.4% and 22.2-30.3% for PU, CVC, %CVC BL , TOI and tHb, respectively. CVs for these variables improved as exercise continued beyond 10 min. CVs for baseline and post-exercise leg blood flow were 17.8% and 10.5%, respectively. CVs for PU, tHb (r 2  = 0.062) and TOI (r 2  = 0.002) were not correlated (P > 0.05). Most variables demonstrated CVs lower than the expected changes (35%) induced by training or heat stress; however, minimum of 10 min exercise is recommended for more reliable measurements.

  14. Atmospheric CO2 Record from Continuous Measurements at Jubany Station, Antarctica (March 1994 - December 2009)

    DOE Data Explorer

    Ciattaglia, Luigi [CNR-IFA, Rome, Italy; Rafanelli, Claudio [CNR-IFA, Rome, Italy; Rodriguez, Horacio [DNA-IAA, Buenos Aires, Argentina; Araujo, Jorge [DNA-IAA, Buenos Aires, Argentina

    2010-03-01

    The Italian PNRA (National Research Program in Antarctica) began continuous atmospheric carbon dioxide measurements at Jubany in 1994. The laboratory at Jubany Station is operated year-round by the DNA (Argentine Antarctic Department) through an agreement with PNRA. The Antarctic station at Jubany (62° 14'S, 58° 40'W) is situated on King George Island, in the South Shetland archipelago north of the Antarctic Penisula. On the basis of annual averages calculated from monthly averages, CO2 levels at Jubany have risen from 356.75 in 1994 to 384.74 in 2009.

  15. Comparison of continuous versus categorical tumor measurement-based metrics to predict overall survival in cancer treatment trials

    PubMed Central

    An, Ming-Wen; Mandrekar, Sumithra J.; Branda, Megan E.; Hillman, Shauna L.; Adjei, Alex A.; Pitot, Henry; Goldberg, Richard M.; Sargent, Daniel J.

    2011-01-01

    Purpose The categorical definition of response assessed via the Response Evaluation Criteria in Solid Tumors has documented limitations. We sought to identify alternative metrics for tumor response that improve prediction of overall survival. Experimental Design Individual patient data from three North Central Cancer Treatment Group trials (N0026, n=117; N9741, n=1109; N9841, n=332) were used. Continuous metrics of tumor size based on longitudinal tumor measurements were considered in addition to a trichotomized response (TriTR: Response vs. Stable vs. Progression). Cox proportional hazards models, adjusted for treatment arm and baseline tumor burden, were used to assess the impact of the metrics on subsequent overall survival, using a landmark analysis approach at 12-, 16- and 24-weeks post baseline. Model discrimination was evaluated using the concordance (c) index. Results The overall best response rates for the three trials were 26%, 45%, and 25% respectively. While nearly all metrics were statistically significantly associated with overall survival at the different landmark time points, the c-indices for the traditional response metrics ranged from 0.59-0.65; for the continuous metrics from 0.60-0.66 and for the TriTR metrics from 0.64-0.69. The c-indices for TriTR at 12-weeks were comparable to those at 16- and 24-weeks. Conclusions Continuous tumor-measurement-based metrics provided no predictive improvement over traditional response based metrics or TriTR; TriTR had better predictive ability than best TriTR or confirmed response. If confirmed, TriTR represents a promising endpoint for future Phase II trials. PMID:21880789

  16. Making to Measure? Reconsidering Assessment in Professional Continuing Education

    ERIC Educational Resources Information Center

    Fenwick, Tara

    2009-01-01

    Drawing on studies of teachers, accountants and pharmacists conducted in Canada, this essay examines models for assessing professional learning that currently enjoy widespread use in continuing education. These models include professional growth plans, self-administered tests and learning logs, and they are often used for regulatory as well as…

  17. Simultaneous and continuous measurements of dissolved CO2, CH4, N2O and CO in rivers using Fourier-Transform-InfraRed (FTIR) spectrometry

    NASA Astrophysics Data System (ADS)

    Warneke, Thorsten; Müller, Denise; Caldow, Christopher; Rixen, Tim; Notholt, Justus

    2015-04-01

    We have coupled a Fourier-Transform InfraRed (FTIR) trace gas analyser to an equilibrator, which allows the simultaneous and continuous measurement of dissolved CO2, CH4, N2O and CO in water. The FTIR-technique has a high precision over a wide range of concentrations, making it very suitable for the measurement of these gases in freshwater systems. We have employed this measurement system on a commercial river barge on the Elbe river (Czech Republic, Germany) and on a fisher boat in the coastal area of Sarawak (Malaysia). In addition we have performed stationary continuous measurements at a small river in Northern Germany over the duration of 3 months. The presentation will outline the advantages and disadvantages of the FTIR-technique for freshwater measurements and will present results from the measurement campaigns.

  18. Reflexology has an acute (immediate) haemodynamic effect in healthy volunteers: a double-blind randomised controlled trial.

    PubMed

    Jones, Jenny; Thomson, Patricia; Lauder, William; Howie, Kate; Leslie, Stephen J

    2012-11-01

    Reflexologists claim that massage to specific points of the feet increases blood supply to internal organs. This study measured changes in cardiovascular parameters in subjects receiving reflexology to areas of their feet thought to correspond to the heart (intervention) compared with other areas which are not (control). 16 reflexology-naive healthy volunteers received an active and control reflexology treatment in an RCT, double-blind repeated measures study. 'Beat-to-beat' continuous measurement of selected cardiovascular parameters, State Anxiety Inventory. Cardiac index decreased significantly in the intervention group during left foot treatment (LFT) (baseline mean 2.6; standard deviation (SD) 0.75; 95% CI ± 0.38 vs. LFT mean 2.45; SD 0.68; CI 0.35), effect size (p = 0.035, omega squared effect (w2) = 0.002; w = 0.045). Reflexology massage applied to the upper part of the left foot may have a modest specific effect on the cardiac index of healthy volunteers. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Definition of yearly emission factor of dust and greenhouse gases through continuous measurements in swine husbandry

    NASA Astrophysics Data System (ADS)

    Costa, Annamaria; Guarino, Marcella

    The object of this study was to develop an accurate estimation method to evaluate the contribution of the various compartments of swine husbandry to dust and GHG (greenhouse gases, CO 2, CH 4 and N 2O) emission into the atmosphere during one year of observation. A weaning, a gestation, a farrowing and a fattening room in an intensive pig house were observed in three different periods (Autumn-Winter, Springtime and Summer, monitoring at least 60% of each period (20% at the beginning, in the middle and at the end) of each cycle). During monitoring, live weight, average live weight gain, number of animals and its variation, type of feed and feeding time were taken into account to evaluate their influence on PM 10, or the fraction of suspended particulate matter with an aerodynamic diameter less than or equal to 10 μm [Emission Inventory Guidebook, 2007. B1100 Particle Emissions from Animal Husbandry Activities. Available from: (accessed October 2008)] and to define GHG emission. The selected piggery had a ventilation control system using a free running impeller to monitor continuously real-time environmental and management parameters with an accuracy of 5%. PM 10 concentration was monitored by a sampler (Haz Dust EPAM 5000), either continuously or through traditional gravimetric technique, and the mean value of dust amount collected on the membranes was utilized as a correction factor to be applied to continuously collected data. PM 10 concentration amount incoming from inlets was removed from PM 10 emission calculation, to estimate the real contribution of pig house dust pollution into atmosphere. Mean yearly emission factor of PM 10 was measured in 2 g d -1 LU -1 for the weaning room, 0.09 g d -1 LU -1 for the farrowing room, 2.59 g d -1 LU -1 for the fattening room and 1.23 g d -1 LU -1 for the gestation room. The highest PM 10 concentration and emission per LU was recorded in the fattening compartment

  20. [Coordination patterns assessed by a continuous measure of joints coupling during upper limb repetitive movements].

    PubMed

    Draicchio, F; Silvetti, A; Ranavolo, A; Iavicoli, S

    2008-01-01

    We analyzed the coordination patterns between elbow, shoulder and trunk in a motor task consisting of reaching out, picking up a cylinder, and transporting it back by using the Dynamical Systems Theory and calculating the continuous relative phase (CRP), a continuous measure of the coupling between two interacting joints. We used an optoelectronic motion analysis system consisting of eight infra-red ray cameras to detect the movements of nine skin-mounted markers. We calculated the root square of the adjusted coefficient of determination, the coefficient of multiple correlation (CMC), in order to investigate the repeatability of the joints coordination. The data confirm that the CNS establishes both synergic (i.e. coupling between shoulder and trunk on the frontal plane) and hierarchical (i.e. coupling between elbow-shoulder-trunk on the horizontal plane) relationships among the available degrees of freedom to overcome the complexity due to motor redundancy. The present study describes a method to investigate the organization of the kinematic degrees of freedom during upper limb multi-joint motor tasks that can be useful to assess upper limb repetitive movements.

  1. New fully automated software for assessment of brachial artery flow- mediated dilation with advantages of continuous measurement.

    PubMed

    Ercan, Ertuğrul; Kırılmaz, Bahadır; Kahraman, İsmail; Bayram, Vildan; Doğan, Hüseyin

    2012-11-01

    Flow-mediated dilation (FMD) is used to evaluate endothelial functions. Computer-assisted analysis utilizing edge detection permits continuous measurements along the vessel wall. We have developed a new fully automated software program to allow accurate and reproducible measurement. FMD has been measured and analyzed in 18 coronary artery disease (CAD) patients and 17 controls both by manually and by the software developed (computer supported) methods. The agreement between methods was assessed by Bland-Altman analysis. The mean age, body mass index and cardiovascular risk factors were higher in CAD group. Automated FMD% measurement for the control subjects was 18.3±8.5 and 6.8±6.5 for the CAD group (p=0.0001). The intraobserver and interobserver correlation for automated measurement was high (r=0.974, r=0.981, r=0.937, r=0.918, respectively). Manual FMD% at 60th second was correlated with automated FMD % (r=0.471, p=0.004). The new fully automated software© can be used to precise measurement of FMD with low intra- and interobserver variability than manual assessment.

  2. An automated microreactor for semi-continuous biosensor measurements.

    PubMed

    Buffi, Nina; Beggah, Siham; Truffer, Frederic; Geiser, Martial; van Lintel, Harald; Renaud, Philippe; van der Meer, Jan Roelof

    2016-04-21

    Living bacteria or yeast cells are frequently used as bioreporters for the detection of specific chemical analytes or conditions of sample toxicity. In particular, bacteria or yeast equipped with synthetic gene circuitry that allows the production of a reliable non-cognate signal (e.g., fluorescent protein or bioluminescence) in response to a defined target make robust and flexible analytical platforms. We report here how bacterial cells expressing a fluorescence reporter ("bactosensors"), which are mostly used for batch sample analysis, can be deployed for automated semi-continuous target analysis in a single concise biochip. Escherichia coli-based bactosensor cells were continuously grown in a 13 or 50 nanoliter-volume reactor on a two-layered polydimethylsiloxane-on-glass microfluidic chip. Physiologically active cells were directed from the nl-reactor to a dedicated sample exposure area, where they were concentrated and reacted in 40 minutes with the target chemical by localized emission of the fluorescent reporter signal. We demonstrate the functioning of the bactosensor-chip by the automated detection of 50 μgarsenite-As l(-1) in water on consecutive days and after a one-week constant operation. Best induction of the bactosensors of 6-9-fold to 50 μg l(-1) was found at an apparent dilution rate of 0.12 h(-1) in the 50 nl microreactor. The bactosensor chip principle could be widely applicable to construct automated monitoring devices for a variety of targets in different environments.

  3. A continuous measure of gross primary production for the conterminous United States derived from MODIS and AmeriFlux data

    Treesearch

    Jingfeng Xiao; Qianlai Zhuang; Beverly E. Law; Jiquan Chen; Dennis D. Baldocchi; David R. Cook; Ram Oren; Andrew D. Richardson; Sonia Wharton; Siyan Ma; Tomothy A. Martin; Shashi B. Verma; Andrew E. Suyker; Russel L. Scott; Russel K. Monson; Marcy Litvak; David Y. Hollinger; Ge Sun; Kenneth J. Davis; Paul V. Bolstad; Sean P. Burns; Peter S. Curtis; BErt G. Drake; Matthias Falk; MArc L. Fischer; David R. Foster; Lianhong Gu; Julian L. Hadley; Gabriel G. Katul; Roser Matamala; Steve McNulty; Tilden P. Meyers; J. William Munger; Asko Noormets; Walter C. Oechel; Kyaw Tha U Paw; Hans Peter Schmid; Gregory Starr; Margaret S. Torn; Steven C. Wofsy

    2010-01-01

    The quantification of carbon fluxes between the terrestrial biosphere and the atmosphere is of scientific importance and also relevant to climate-policy making. Eddy covariance flux towers provide continuous measurements of ecosystem-level exchange of carbon dioxide spanning diurnal, synoptic, seasonal, and interannual time scales....

  4. Accuracy of delta 18O isotope ratio measurements on the same sample by continuous-flow isotope-ratio mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    The doubly labeled water method is considered the reference method to measure energy expenditure. Conventional mass spectrometry requires a separate aliquot of the same sample to be prepared and analyzed separately. With continuous-flow isotope-ratio mass spectrometry, the same sample could be analy...

  5. Continuous Dissolved Oxygen Measurements and Modelling Metabolism in Peatland Streams

    PubMed Central

    Dick, Jonathan J.; Soulsby, Chris; Birkel, Christian; Malcolm, Iain; Tetzlaff, Doerthe

    2016-01-01

    Stream water dissolved oxygen was monitored in a 3.2km2 moorland headwater catchment in the Scottish Highlands. The stream consists of three 1st order headwaters and a 2nd order main stem. The stream network is fringed by peat soils with no riparian trees, though dwarf shrubs provide shading in the lower catchment. Dissolved oxygen (DO) is regulated by the balance between atmospheric re-aeration and the metabolic processes of photosynthesis and respiration. DO was continuously measured for >1 year and the data used to calibrate a mass balance model, to estimate primary production, respiration and re-aeration for a 1st order site and in the 2nd order main stem. Results showed that the stream was always heterotrophic at both sites. Sites were most heterotrophic in the summer reflecting higher levels of stream metabolism. The 1st order stream appeared more heterotrophic which was consistent with the evident greater biomass of macrophytes in the 2nd order stream, with resulting higher primary productivity. Comparison between respiration, primary production, re-aeration and potential physical controls revealed only weak relationships. However, the most basic model parameters (e.g. the parameter linking light and photosynthesis) controlling ecosystem processes resulted in significant differences between the sites which seem related to the stream channel geometry. PMID:27556278

  6. Renal function in juvenile rats subjected to prenatal malnutrition and chronic salt overload.

    PubMed

    Magalhães, João Carlos G; da Silveira, Alex B; Mota, Diogenes L; Paixão, Ana Durce O

    2006-05-01

    Dietary sodium may contribute to hypertension and to cardiovascular and renal disease if a primary deficiency of the kidney to excrete sodium exists. In order to investigate whether chronic 1% NaCl in the drinking water changes blood pressure and renal haemodynamics in juvenile Wistar rats subjected to prenatal malnutrition, an evaluation of plasma volume, oxidative stress in the kidney, proteinuria and renal haemodynamics was carried out. Malnutrition was induced by a multideficient diet. Mean arterial pressure, renal blood flow and glomerular filtration rate (GFR) were measured using a blood pressure transducer, a flow probe and inulin clearance, respectively. Plasma volume and oxidative stress were measured by means of the Evans Blue method and by monitoring thiobarbituric acid reactive substances (TBARS) in the kidneys, respectively. Urinary protein was measured by precipitation with 3% sulphosalicylic acid. It was observed that prenatally malnourished rats presented higher values of plasma volume (26%, P < 0.05), kidney TBARS (43%, P < 0.01) and blood pressure (10%, P < 0.01) when compared with the control group. However, they showed no change in renal haemodynamics or proteinuria. Neither prenatally malnourished nor control rats treated with sodium overload presented plasma volume or blood pressure values different from their respective control groups, but both groups presented elevated proteinuria (P < 0.01). The prenatally malnourished group treated with sodium overload presented higher values of kidney TBARS, GFR and filtration fraction (58, 87 and 72% higher, respectively, P < 0.01) than its respective control group. In summary, sodium overload did not exacerbate the hypertension in juvenile prenatally malnourished rats, but induced renal haemodynamic adjustments compatible with the development of renal disease.

  7. Effects of loxoprofen sodium, a newly synthesized non-steroidal anti-inflammatory drug, and indomethacin on gastric mucosal haemodynamics in the human.

    PubMed

    Kawano, S; Tsuji, S; Hayashi, N; Takei, Y; Nagano, K; Fusamoto, H; Kamada, T

    1995-01-01

    Non-steroidal anti-inflammatory drugs (NSAID) are, and have been, frequently used for alleviation of pain in patients; however, they are known to cause gastric mucosal injury in experimental animals and in humans. A decrease in the gastric mucosal blood flow also plays an important role in the aetiology of acute gastric mucosal injury, as we previously reported. This study investigated the effect of a newly synthesized NSAID, loxoprofen sodium (sodium 2[p-2 oxocyclopentylmethyl) phenyl]propionate dihydrate, on gastric mucosal haemodynamics using a reflectance spectrophotometry system. Both single and cross-over methods were used in five volunteer subjects. Loxoprofen sodium 60 mg (one tablet) or indomethacin 25 mg (one tablet), was diluted in 10 mL water at 25 degrees C and sprayed on the gastric mucosa via a polyethylene tube inserted into the biopsy channel of an endoscope. After drug administration, reflectance spectra were taken every 5 min for 30 min. The indices of mucosal haemoglobin content (IHb) and oxygen saturation of haemoglobin (ISO2) were determined by the method previously reported by the authors. Indomethacin administration produced a significant decrease in both IHb and ISO2 values, indication ischaemia. Loxoprofen sodium, however, showed no significant differences in either of the parameters. Haemorrhagic erosions were evident after indomethacin administration, but none were found after loxoprofen sodium administration. The conclusion reached on the basis of this evidence is that one-time topical application of loxoprofen sodium is safer than indomethacin.

  8. Diagnosis of subacute ruminal acidosis (SARA) by continuous reticular pH measurements in cows.

    PubMed

    Sato, Shigeru; Ikeda, Aya; Tsuchiya, Yoshiyuki; Ikuta, Kentaro; Murayama, Isao; Kanehira, Masahiro; Okada, Keiji; Mizuguchi, Hitoshi

    2012-09-01

    The objective of this study was to determine whether subacute ruminal acidosis (SARA) could be diagnosed by continuous measurements of the reticular pH, as compared with the ruminal pH, using healthy cows fed a control diet and SARA cows fed a rumen acidosis-inducing diet. The reticular and ruminal pH were measured simultaneously by a radio transmission pH measurement system. The mean reticular pH at 1-h intervals decreased gradually from the morning feeding to the next feeding time in both healthy and SARA cows, though the decrease in the ruminal pH was observed to be more drastic as compared with that observed in the reticular pH. The threshold of the 1-h mean pH in the reticulum for a diagnosis of SARA was considered to be 6.3, and a significant positive correlation was observed between the reticular and ruminal pH. No differences in the concentrations of lactic acid, ammonia nitrogen, and volatile fatty acids were noted between the reticular and ruminal fluids in SARA cows. These results demonstrate that the reticular pH can be used to detect SARA in cows, as opposed to using the ruminal pH.

  9. Entanglement enhancement through multirail noise reduction for continuous-variable measurement-based quantum-information processing

    NASA Astrophysics Data System (ADS)

    Su, Yung-Chao; Wu, Shin-Tza

    2017-09-01

    We study theoretically the teleportation of a controlled-phase (cz) gate through measurement-based quantum-information processing for continuous-variable systems. We examine the degree of entanglement in the output modes of the teleported cz-gate for two classes of resource states: the canonical cluster states that are constructed via direct implementations of two-mode squeezing operations and the linear-optical version of cluster states which are built from linear-optical networks of beam splitters and phase shifters. In order to reduce the excess noise arising from finite-squeezed resource states, teleportation through resource states with different multirail designs will be considered and the enhancement of entanglement in the teleported cz gates will be analyzed. For multirail cluster with an arbitrary number of rails, we obtain analytical expressions for the entanglement in the output modes and analyze in detail the results for both classes of resource states. At the same time, we also show that for uniformly squeezed clusters the multirail noise reduction can be optimized when the excess noise is allocated uniformly to the rails. To facilitate the analysis, we develop a trick with manipulations of quadrature operators that can reveal rather efficiently the measurement sequence and corrective operations needed for the measurement-based gate teleportation, which will also be explained in detail.

  10. Calibration and use of continuous heat-type automated seepage meters for submarine groundwater discharge measurements

    USGS Publications Warehouse

    Mwashote, B.M.; Burnett, W.C.; Chanton, J.; Santos, I.R.; Dimova, N.; Swarzenski, P.W.

    2010-01-01

    Submarine groundwater discharge (SGD) assessments were conducted both in the laboratory and at a field site in the northeastern Gulf of Mexico, using a continuous heat-type automated seepage meter (seepmeter). The functioning of the seepmeter is based on measurements of a temperature gradient in the water between downstream and upstream positions in its flow pipe. The device has the potential of providing long-term, high-resolution measurements of SGD. Using a simple inexpensive laboratory set-up, we have shown that connecting an extension cable to the seepmeter has a negligible effect on its measuring capability. Similarly, the observed influence of very low temperature (???3 ??C) on seepmeter measurements can be accounted for by conducting calibrations at such temperatures prior to field deployments. Compared to manual volumetric measurements, calibration experiments showed that at higher water flow rates (>28 cm day-1 or cm3 cm-2 day-1) an analog flowmeter overestimated flow rates by ???7%. This was apparently due to flow resistance, turbulence and formation of air bubbles in the seepmeter water flow tubes. Salinity had no significant effect on the performance of the seepmeter. Calibration results from fresh water and sea water showed close agreement at a 95% confidence level significance between the data sets from the two media (R2 = 0.98). Comparatively, the seepmeter SGD measurements provided data that are comparable to manually-operated seepage meters, the radon geochemical tracer approach, and an electromagnetic (EM) seepage meter. ?? 2009 Elsevier Ltd.

  11. A simple technique for continuous measurement of time-variable gas transfer in surface waters

    USGS Publications Warehouse

    Tobias, Craig R.; Bohlke, John Karl; Harvey, Judson W.; Busenberg, Eurybiades

    2009-01-01

    Mass balance models of dissolved gases in streams, lakes, and rivers serve as the basis for estimating wholeecosystem rates for various biogeochemical processes. Rates of gas exchange between water and the atmosphere are important and error-prone components of these models. Here we present a simple and efficient modification of the SF6 gas tracer approach that can be used concurrently while collecting other dissolved gas samples for dissolved gas mass balance studies in streams. It consists of continuously metering SF6-saturated water directly into the stream at a low rate of flow. This approach has advantages over pulse injection of aqueous solutions or bubbling large amounts of SF6 into the stream. By adding the SF6 as a saturated solution, we minimize the possibility that other dissolved gas measurements are affected by sparging and/or bubble injecta. Because the SF6 is added continuously we have a record of changing gas transfer velocity (GTV) that is contemporaneous with the sampling of other nonconservative ambient dissolved gases. Over a single diel period, a 30% variation in GTV was observed in a second-order stream (Sugar Creek, Indiana, USA). The changing GTV could be attributed in part to changes in temperature and windspeed that occurred on hourly to diel timescales.

  12. Measurement of air exchange rates in different indoor environments using continuous CO2 sensors.

    PubMed

    You, Yan; Niu, Can; Zhou, Jian; Liu, Yating; Bai, Zhipeng; Zhang, Jiefeng; He, Fei; Zhang, Nan

    2012-01-01

    A new air exchange rate (AER) monitoring method using continuous CO2 sensors was developed and validated through both laboratory experiments and field studies. Controlled laboratory simulation tests were conducted in a 1-m3 environmental chamber at different AERs (0.1-10.0 hr(-1)). AERs were determined using the decay method based on box model assumptions. Field tests were conducted in classrooms, dormitories, meeting rooms and apartments during 2-5 weekdays using CO2 sensors coupled with data loggers. Indoor temperature, relative humidity (RH), and CO2 concentrations were continuously monitored while outdoor parameters combined with on-site climate conditions were recorded. Statistical results indicated that good laboratory performance was achieved: duplicate precision was within 10%, and the measured AERs were 90%-120% of the real AERs. Average AERs were 1.22, 1.37, 1.10, 1.91 and 0.73 hr(-1) in dormitories, air-conditioned classrooms, classrooms with an air circulation cooling system, reading rooms, and meeting rooms, respectively. In an elderly particulate matter exposure study, all the homes had AER values ranging from 0.29 to 3.46 hr(-1) in fall, and 0.12 to 1.39 hr(-1) in winter with a median AER of 1.15.

  13. Comparison of continuous versus categorical tumor measurement-based metrics to predict overall survival in cancer treatment trials.

    PubMed

    An, Ming-Wen; Mandrekar, Sumithra J; Branda, Megan E; Hillman, Shauna L; Adjei, Alex A; Pitot, Henry C; Goldberg, Richard M; Sargent, Daniel J

    2011-10-15

    The categorical definition of response assessed via the Response Evaluation Criteria in Solid Tumors has documented limitations. We sought to identify alternative metrics for tumor response that improve prediction of overall survival. Individual patient data from three North Central Cancer Treatment Group trials (N0026, n = 117; N9741, n = 1,109; and N9841, n = 332) were used. Continuous metrics of tumor size based on longitudinal tumor measurements were considered in addition to a trichotomized response [TriTR: response (complete or partial) vs. stable disease vs. progression). Cox proportional hazards models, adjusted for treatment arm and baseline tumor burden, were used to assess the impact of the metrics on subsequent overall survival, using a landmark analysis approach at 12, 16, and 24 weeks postbaseline. Model discrimination was evaluated by the concordance (c) index. The overall best response rates for the three trials were 26%, 45%, and 25%, respectively. Although nearly all metrics were statistically significantly associated with overall survival at the different landmark time points, the concordance indices (c-index) for the traditional response metrics ranged from 0.59 to 0.65; for the continuous metrics from 0.60 to 0.66; and for the TriTR metrics from 0.64 to 0.69. The c-indices for TriTR at 12 weeks were comparable with those at 16 and 24 weeks. Continuous tumor measurement-based metrics provided no predictive improvement over traditional response-based metrics or TriTR; TriTR had better predictive ability than best TriTR or confirmed response. If confirmed, TriTR represents a promising endpoint for future phase II trials. ©2011 AACR.

  14. Continuous glucose monitoring in newborn infants: how do errors in calibration measurements affect detected hypoglycemia?

    PubMed

    Thomas, Felicity; Signal, Mathew; Harris, Deborah L; Weston, Philip J; Harding, Jane E; Shaw, Geoffrey M; Chase, J Geoffrey

    2014-05-01

    Neonatal hypoglycemia is common and can cause serious brain injury. Continuous glucose monitoring (CGM) could improve hypoglycemia detection, while reducing blood glucose (BG) measurements. Calibration algorithms use BG measurements to convert sensor signals into CGM data. Thus, inaccuracies in calibration BG measurements directly affect CGM values and any metrics calculated from them. The aim was to quantify the effect of timing delays and calibration BG measurement errors on hypoglycemia metrics in newborn infants. Data from 155 babies were used. Two timing and 3 BG meter error models (Abbott Optium Xceed, Roche Accu-Chek Inform II, Nova Statstrip) were created using empirical data. Monte-Carlo methods were employed, and each simulation was run 1000 times. Each set of patient data in each simulation had randomly selected timing and/or measurement error added to BG measurements before CGM data were calibrated. The number of hypoglycemic events, duration of hypoglycemia, and hypoglycemic index were then calculated using the CGM data and compared to baseline values. Timing error alone had little effect on hypoglycemia metrics, but measurement error caused substantial variation. Abbott results underreported the number of hypoglycemic events by up to 8 and Roche overreported by up to 4 where the original number reported was 2. Nova results were closest to baseline. Similar trends were observed in the other hypoglycemia metrics. Errors in blood glucose concentration measurements used for calibration of CGM devices can have a clinically important impact on detection of hypoglycemia. If CGM devices are going to be used for assessing hypoglycemia it is important to understand of the impact of these errors on CGM data. © 2014 Diabetes Technology Society.

  15. An ROC-type measure of diagnostic accuracy when the gold standard is continuous-scale.

    PubMed

    Obuchowski, Nancy A

    2006-02-15

    ROC curves and summary measures of accuracy derived from them, such as the area under the ROC curve, have become the standard for describing and comparing the accuracy of diagnostic tests. Methods for estimating ROC curves rely on the existence of a gold standard which dichotomizes patients into disease present or absent. There are, however, many examples of diagnostic tests whose gold standards are not binary-scale, but rather continuous-scale. Unnatural dichotomization of these gold standards leads to bias and inconsistency in estimates of diagnostic accuracy. In this paper, we propose a non-parametric estimator of diagnostic test accuracy which does not require dichotomization of the gold standard. This estimator has an interpretation analogous to the area under the ROC curve. We propose a confidence interval for test accuracy and a statistical test for comparing accuracies of tests from paired designs. We compare the performance (i.e. CI coverage, type I error rate, power) of the proposed methods with several alternatives. An example is presented where the accuracies of two quick blood tests for measuring serum iron concentrations are estimated and compared.

  16. Continuous spectroscopic measurement of methane isotopes and ethane made on board an aircraft: instrument configuration and characterisation

    NASA Astrophysics Data System (ADS)

    Pitt, Joseph; Young, Stuart; Hopkins, James; Lee, James; Bauguitte, Stéphane; Dorsey, James; Allen, Grant; Gallagher, Martin; Yacovitch, Tara; Zahniser, Mark; Fisher, Rebecca; Lowry, Dave; Nisbet, Euan

    2017-04-01

    We describe the configuration of two commercially available absorption spectrometers for use on board the UK Facility for Airborne Atmospheric Research (FAAM) aircraft. A dual laser instrument has been used to make continuous measurements of the atmospheric 13CH4:12CH4 ratio and ethane mole fraction, using an interband cascade laser (ICL) and a recently developed type of diode laser respectively. Simultaneous measurements of atmospheric ethane have also been made using a single laser instrument employing an ICL, enabling instrument inter-comparison. Instrument performance is evaluated over a series of test flights, and initial results from the MOYA (Methane Observations and Yearly Assessments) campaign, targeting biomass burning plumes in west Africa, are also presented. We describe the calibration procedure and data analysis approaches for methane isotope measurement, involving calibration over a range of methane isotopic composition and methane mole fraction. We assess the effectiveness of this calibration technique during the first MOYA campaign period using measurements of a target cylinder of known composition.

  17. Continuous-variable measurement-device-independent quantum key distribution: Composable security against coherent attacks

    NASA Astrophysics Data System (ADS)

    Lupo, Cosmo; Ottaviani, Carlo; Papanastasiou, Panagiotis; Pirandola, Stefano

    2018-05-01

    We present a rigorous security analysis of continuous-variable measurement-device-independent quantum key distribution (CV MDI QKD) in a finite-size scenario. The security proof is obtained in two steps: by first assessing the security against collective Gaussian attacks, and then extending to the most general class of coherent attacks via the Gaussian de Finetti reduction. Our result combines recent state-of-the-art security proofs for CV QKD with findings about min-entropy calculus and parameter estimation. In doing so, we improve the finite-size estimate of the secret key rate. Our conclusions confirm that CV MDI protocols allow for high rates on the metropolitan scale, and may achieve a nonzero secret key rate against the most general class of coherent attacks after 107-109 quantum signal transmissions, depending on loss and noise, and on the required level of security.

  18. Field continuous measurement of dissolved gases with a CF-MIMS: Applications to the physics and biogeochemistry of groundwater flow

    NASA Astrophysics Data System (ADS)

    Chatton, Eliot; Labasque, Thierry; de La Bernardie, Jérôme; Guihéneuf, Nicolas; Bour, Olivier; Aquilina, Luc

    2017-04-01

    In the perspective of a temporal and spatial exploration of aquatic environments (surface and ground water), we developed a technique for precise field continuous measurements of dissolved gases (N2, O2, CO2, CH4, N2O, H2, He, Ne, Ar, Kr, Xe). With a large resolution (from 1×10-9 to 1×10-2 ccSTP/g) and a capability of high frequency analysis (1 measure every 2 seconds), the CF-MIMS (Continuous Flow Membrane Inlet Mass Spectrometer) is an innovative tool allowing the investigation of a large panel of hydrological and biogeochemical processes in aquatic systems. Based on the available MIMS technology, this study introduces the development of the CF-MIMS (conception for field experiments, membrane choices, ionisation) and an original calibration procedure allowing the quantification of mass spectral overlaps and temperature effects on membrane permeability. This study also presents two field applications of the CF-MIMS (Chatton et al, 2016) involving the well-logging of dissolved gases and the implementation of groundwater tracer tests with dissolved 4He. The results demonstrate the analytical capabilities of the CF-MIMS in the field. Therefore, the CF-MIMS is a valuable tool for the field characterisation of biogeochemical reactivity, aquifer transport properties, groundwater recharge, groundwater residence time and aquifer-river exchanges from few hours to several weeks experiments. Eliot Chatton, Thierry Labasque, Jérôme de La Bernardie, Nicolas Guihéneuf, Olivier Bour and Luc Aquilina; Field Continuous Measurement of Dissolved Gases with a CF-MIMS: Applications to the Physics and Biogeochemistry of Groundwater Flow; Environmental Science & Technology, in press, 2016.

  19. Technical note: development and testing of a radio transmission pH measurement system for continuous monitoring of ruminal pH in cows.

    PubMed

    Sato, Shigeru; Mizuguchi, Hitoshi; Ito, Kazunori; Ikuta, Kentaro; Kimura, Atushi; Okada, Keiji

    2012-03-01

    An indwelling ruminal pH system has been used for the continuous recording of ruminal pH to evaluate subacute ruminal acidosis (SARA) in dairy cows. However this system does not allow the field application. The objective of this study was to develop a new radio transmission pH measurement system, and to assess its performance and usefulness in a continuous evaluation of ruminal pH for use on commercial dairy farms. The radio transmission pH measurement system consists of a wireless pH sensor, a data measurement receiver, a relay unit, and a personal computer installed special software. The pH sensor is housed in a bullet shaped bolus, which also encloses a pH amplifier circuit, a central processing unit (CPU) circuit, a radio frequency (RF) circuit, and a battery. The mean variations of the measurements by the glass pH electrode were +0.20 (n=10) after 2 months of continuous recording, compared to the values confirmed by standard pH solutions for pH 4 and pH 7 at the start of the recording. The mean lifetime of the internal battery was 2.5 months (n=10) when measurements were continuously transmitted every 10 min. Ruminal pH recorded by our new system was compared to that of the spot sampling of ruminal fluid. The mean pH for spot sampling was 6.36 ± 0.55 (n=96), and the mean pH of continuous recording was 6.22 ± 0.54 (n=96). There was a good correlation between continuous recording and spot sampling (r=0.986, P<0.01). We also examined whether our new pH system was able to detect experimentally induced ruminal acidosis in cows and to record long-term changes in ruminal pH. In the cows fed acidosis-inducing diets, the ruminal pH dropped markedly during the first 2h following the morning feeding, and decreased moreover following the evening feeding, with many pulse-like pH changes. The pH of the cows showed the lowest values of 5.3-5.2 in the midnight time period and it recovered to the normal value by the next morning feeding. In one healthy periparturient cow

  20. Evolution of target organ damage and haemodynamic parameters over 4 years in patients with increased insulin resistance: the LOD-DIABETES prospective observational study.

    PubMed

    Gómez-Marcos, Manuel Ángel; Recio-Rodríguez, José Ignacio; Patino-Alonso, María Carmen; Agudo-Conde, Cristina; Rodríguez-Sanchez, Emiliano; Maderuelo-Fernandez, Jose Angel; Gómez-Sánchez, Leticia; Gomez-Sanchez, Marta; García-Ortiz, Luís

    2016-06-01

    We prospectively examined the impact of type 2 diabetes compared with metabolic syndrome (MetS) on the development of vascular disease over 4 years as determined by anatomic and functional markers of vascular disease. By comparing the vascular outcomes of the 2 disorders, we seek to determine the independent effect of elevated glucose levels on vascular disease. 2 primary care centres in Salamanca, Spain. We performed a prospective observational study involving 112 patients (68 with type 2 diabetes and 44 with MetS) who were followed for 4 years. Measurements included blood pressure, blood glucose, lipids, smoking, body mass index, waist circumference, Homeostasis Model Assessment Insulin Resistance (HOMA-IR), hs-c-reactive protein and fibrinogen levels. We also evaluated vascular, carotid intima media thickness (IMT), pulse wave velocity (PWV) and ankle/brachial index, heart and renal target organ damage (TOD). The haemodynamic parameters were central (CAIx) and peripheral (PAIx) augmentation indices. In year 4, participants with type 2 diabetes had increased IMT thickness. These patients had more plaques and an IMT>0.90 mm. In participants with MetS, we only found an increase in the number of plaques. We found no changes in PWV, CAIx and PAIx. The patients with diabetes had a greater frequency of vascular TOD. There were no differences neither in renal nor cardiac percentage of TOD in the patients with MetS or diabetes mellitus type 2. This prospective study showed that the evolution of vascular TOD is different in participants with type 2 diabetes compared with those with MetS. While IMT and PWV increased in type 2 diabetes, these were not modified in MetS. The renal and cardiac TOD evolution, as well as the PAIx and CAIx, did not change in either group. NCT01065155; Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Continuous Flow Hygroscopicity-Resolved Relaxed Eddy Accumulation (Hy-Res REA) Method of Measuring Size-Resolved Sea-Salt Particle Fluxes

    NASA Astrophysics Data System (ADS)

    Meskhidze, N.; Royalty, T. M.; Phillips, B.; Dawson, K. W.; Petters, M. D.; Reed, R.; Weinstein, J.; Hook, D.; Wiener, R.

    2017-12-01

    The accurate representation of aerosols in climate models requires direct ambient measurement of the size- and composition-dependent particle production fluxes. Here we present the design, testing, and analysis of data collected through the first instrument capable of measuring hygroscopicity-based, size-resolved particle fluxes using a continuous-flow Hygroscopicity-Resolved Relaxed Eddy Accumulation (Hy-Res REA) technique. The different components of the instrument were extensively tested inside the US Environmental Protection Agency's Aerosol Test Facility for sea-salt and ammoniums sulfate particle fluxes. The new REA system design does not require particle accumulation, therefore avoids the diffusional wall losses associated with long residence times of particles inside the air collectors of the traditional REA devices. The Hy-Res REA system used in this study includes a 3-D sonic anemometer, two fast-response solenoid valves, two Condensation Particle Counters (CPCs), a Scanning Mobility Particle Sizer (SMPS), and a Hygroscopicity Tandem Differential Mobility Analyzer (HTDMA). A linear relationship was found between the sea-salt particle fluxes measured by eddy covariance and REA techniques, with comparable theoretical (0.34) and measured (0.39) proportionality constants. The sea-salt particle detection limit of the Hy-Res REA flux system is estimated to be 6x105 m-2s-1. For the conditions of ammonium sulfate and sea-salt particles of comparable source strength and location, the continuous-flow Hy-Res REA instrument was able to achieve better than 90% accuracy of measuring the sea-salt particle fluxes. In principle, the instrument can be applied to measure fluxes of particles of variable size and distinct hygroscopic properties (i.e., mineral dust, black carbon, etc.).

  2. A repeated measures model for analysis of continuous outcomes in sequential parallel comparison design studies.

    PubMed

    Doros, Gheorghe; Pencina, Michael; Rybin, Denis; Meisner, Allison; Fava, Maurizio

    2013-07-20

    Previous authors have proposed the sequential parallel comparison design (SPCD) to address the issue of high placebo response rate in clinical trials. The original use of SPCD focused on binary outcomes, but recent use has since been extended to continuous outcomes that arise more naturally in many fields, including psychiatry. Analytic methods proposed to date for analysis of SPCD trial continuous data included methods based on seemingly unrelated regression and ordinary least squares. Here, we propose a repeated measures linear model that uses all outcome data collected in the trial and accounts for data that are missing at random. An appropriate contrast formulated after the model has been fit can be used to test the primary hypothesis of no difference in treatment effects between study arms. Our extensive simulations show that when compared with the other methods, our approach preserves the type I error even for small sample sizes and offers adequate power and the smallest mean squared error under a wide variety of assumptions. We recommend consideration of our approach for analysis of data coming from SPCD trials. Copyright © 2013 John Wiley & Sons, Ltd.

  3. Proposing a New Conceptual Model and an Exemplar Measure Using Health Information: Technology to Examine the Impact of Relational Nurse Continuity on Hospital-Acquired Pressure Ulcers

    PubMed Central

    STIFTER, Janet; YAO, Yingwei; LOPEZ, Karen Dunn; KHOKHAR, Ashfaq; WILKIE, Diana J.; KEENAN, Gail M.

    2015-01-01

    The influence of the staffing variable nurse continuity on patient outcomes has been rarely studied and with inconclusive results. Multiple definitions and an absence of systematic methods for measuring the influence of continuity have resulted in its exclusion from nurse-staffing studies and conceptual models. We present a new conceptual model and an innovative use of health information technology to measure nurse continuity and to demonstrate the potential for bringing the results of big data science back to the bedside. Understanding the power of big data to address critical clinical issues may foster a new direction for nursing administration theory development. PMID:26244480

  4. Variability in and agreement between modeled and personal continuously measured black carbon levels using novel smartphone and sensor technologies.

    PubMed

    Nieuwenhuijsen, Mark J; Donaire-Gonzalez, David; Rivas, Ioar; de Castro, Montserrat; Cirach, Marta; Hoek, Gerard; Seto, Edmund; Jerrett, Michael; Sunyer, Jordi

    2015-03-03

    Novel technologies, such as smartphones and small personal continuous air pollution sensors, can now facilitate better personal estimates of air pollution in relation to location. Such information can provide us with a better understanding about whether and how personal exposures relate to residential air pollution estimates, which are normally used in epidemiological studies. The aims of this study were to examine (1) the variability in personal air pollution levels during the day and (2) the relationship between modeled home and school estimates and continuously measured personal air pollution exposure levels in different microenvironments (e.g., home, school, and commute). We focused on black carbon as an indicator of traffic-related air pollution. We recruited 54 school children (aged 7-11) from 29 different schools around Barcelona as part of the BREATHE study, an epidemiological study of the relation between air pollution and brain development. For 2 typical week days during 2012-2013, the children were given a smartphone with CalFit software to obtain information on their location and physical activity level and a small sensor, the micro-aethalometer model AE51, to measure their black carbon levels simultaneously and continuously. We estimated their home and school exposure to PM2.5 filter absorbance, which is well-correlated with black carbon, using a temporally adjusted PM2.5 absorbance land use regression (LUR) model. We found considerable variation in the black carbon levels during the day, with the highest levels measured during commuting periods (geometric mean = 2.8 μg/m(3)) and the lowest levels at home (geometric mean = 1.3 μg/m(3)). Hourly temporally adjusted LUR model estimates for the home and school showed moderate to good correlation with measured personal black carbon levels at home and school (r = 0.59 and 0.68, respectively) and lower correlation with commuting trips (r = 0.32 and 0.21, respectively). The correlation between modeled home

  5. Intensity-Modulated Continuous-Wave Laser Absorption Spectrometer at 1.57 Micrometer for Atmospheric CO2 Measurements

    NASA Technical Reports Server (NTRS)

    Lin, Bing

    2014-01-01

    Understanding the earth's carbon cycle is essential for diagnosing current and predicting future climates, which requires precise global measurements of atmospheric CO2 through space missions. The Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission will provide accurate global atmospheric CO2 measurements to meet carbon science requirements. The joint team of NASA Langley Research Center and ITT Exelis, Inc. proposes to use the intensity-modulated, continuous-wave (IM-CW) laser absorption spectrometer (LAS) approach for the ASCENDS mission. Prototype LAS instruments have been developed and used to demonstrate the power, signal-to-noise ratio, precision and accuracy, spectral purity, and stability of the measurement and the instrument needed for atmospheric CO2 observations from space. The ranging capability from laser platform to ground surfaces or intermediate backscatter layers is achieved by transmitted range-encoded IM laser signals. Based on the prototype instruments and current lidar technologies, space LAS systems and their CO2 column measurements are analyzed. These studies exhibit a great potential of using IM-CW LAS system for the active space CO2 mission ASCENDS.

  6. A Simulation Study of Categorizing Continuous Exposure Variables Measured with Error in Autism Research: Small Changes with Large Effects.

    PubMed

    Heavner, Karyn; Burstyn, Igor

    2015-08-24

    Variation in the odds ratio (OR) resulting from selection of cutoffs for categorizing continuous variables is rarely discussed. We present results for the effect of varying cutoffs used to categorize a mismeasured exposure in a simulated population in the context of autism spectrum disorders research. Simulated cohorts were created with three distinct exposure-outcome curves and three measurement error variances for the exposure. ORs were calculated using logistic regression for 61 cutoffs (mean ± 3 standard deviations) used to dichotomize the observed exposure. ORs were calculated for five categories with a wide range for the cutoffs. For each scenario and cutoff, the OR, sensitivity, and specificity were calculated. The three exposure-outcome relationships had distinctly shaped OR (versus cutoff) curves, but increasing measurement error obscured the shape. At extreme cutoffs, there was non-monotonic oscillation in the ORs that cannot be attributed to "small numbers." Exposure misclassification following categorization of the mismeasured exposure was differential, as predicted by theory. Sensitivity was higher among cases and specificity among controls. Cutoffs chosen for categorizing continuous variables can have profound effects on study results. When measurement error is not too great, the shape of the OR curve may provide insight into the true shape of the exposure-disease relationship.

  7. Protective ventilation of preterm lambs exposed to acute chorioamnionitis does not reduce ventilation-induced lung or brain injury.

    PubMed

    Barton, Samantha K; Moss, Timothy J M; Hooper, Stuart B; Crossley, Kelly J; Gill, Andrew W; Kluckow, Martin; Zahra, Valerie; Wong, Flora Y; Pichler, Gerhard; Galinsky, Robert; Miller, Suzanne L; Tolcos, Mary; Polglase, Graeme R

    2014-01-01

    The onset of mechanical ventilation is a critical time for the initiation of cerebral white matter (WM) injury in preterm neonates, particularly if they are inadvertently exposed to high tidal volumes (VT) in the delivery room. Protective ventilation strategies at birth reduce ventilation-induced lung and brain inflammation and injury, however its efficacy in a compromised newborn is not known. Chorioamnionitis is a common antecedent of preterm birth, and increases the risk and severity of WM injury. We investigated the effects of high VT ventilation, after chorioamnionitis, on preterm lung and WM inflammation and injury, and whether a protective ventilation strategy could mitigate the response. Pregnant ewes (n = 18) received intra-amniotic lipopolysaccharide (LPS) 2 days before delivery, instrumentation and ventilation at 127±1 days gestation. Lambs were either immediately euthanased and used as unventilated controls (LPSUVC; n = 6), or were ventilated using an injurious high VT strategy (LPSINJ; n = 5) or a protective ventilation strategy (LPSPROT; n = 7) for a total of 90 min. Mean arterial pressure, heart rate and cerebral haemodynamics and oxygenation were measured continuously. Lungs and brains underwent molecular and histological assessment of inflammation and injury. LPSINJ lambs had poorer oxygenation than LPSPROT lambs. Ventilation requirements and cardiopulmonary and systemic haemodynamics were not different between ventilation strategies. Compared to unventilated lambs, LPSINJ and LPSPROT lambs had increases in pro-inflammatory cytokine expression within the lungs and brain, and increased astrogliosis (p<0.02) and cell death (p<0.05) in the WM, which were equivalent in magnitude between groups. Ventilation after acute chorioamnionitis, irrespective of strategy used, increases haemodynamic instability and lung and cerebral inflammation and injury. Mechanical ventilation is a potential contributor to WM injury in infants exposed to

  8. Neurovascular and neuroimaging effects of the hallucinogenic serotonin receptor agonist psilocin in the rat brain

    PubMed Central

    Spain, Aisling; Howarth, Clare; Khrapitchev, Alexandre A.; Sharp, Trevor; Sibson, Nicola R.; Martin, Chris

    2015-01-01

    The development of pharmacological magnetic resonance imaging (phMRI) has presented the opportunity for investigation of the neurophysiological effects of drugs in vivo. Psilocin, a hallucinogen metabolised from psilocybin, was recently reported to evoke brain region-specific, phMRI signal changes in humans. The present study investigated the effects of psilocin in a rat model using phMRI and then probed the relationship between neuronal and haemodynamic responses using a multimodal measurement preparation. Psilocin (2 mg/kg or 0.03 mg/kg i.v.) or vehicle was administered to rats (N = 6/group) during either phMRI scanning or concurrent imaging of cortical blood flow and recording of local field potentials. Compared to vehicle controls psilocin (2 mg/kg) evoked phMRI signal increases in a number of regions including olfactory and limbic areas and elements of the visual system. PhMRI signal decreases were seen in other regions including somatosensory and motor cortices. Investigation of neurovascular coupling revealed that whilst neuronal responses (local field potentials) to sensory stimuli were decreased in amplitude by psilocin administration, concurrently measured haemodynamic responses (cerebral blood flow) were enhanced. The present findings show that psilocin evoked region-specific changes in phMRI signals in the rat, confirming recent human data. However, the results also suggest that the haemodynamic signal changes underlying phMRI responses reflect changes in both neuronal activity and neurovascular coupling. This highlights the importance of understanding the neurovascular effects of pharmacological manipulations for interpreting haemodynamic neuroimaging data. PMID:26192543

  9. Creating meaningful business continuity management programme metrics.

    PubMed

    Strong, Brian

    2010-11-01

    The popular axiom, 'what gets measured gets done', is often applied in the quality management and continuous improvement disciplines. This truism is also useful to business continuity practitioners as they continually strive to prove the value of their organisation's investment in a business continuity management (BCM) programme. BCM practitioners must also remain relevant to their organisations as executives focus on the bottom line and maintaining stakeholder confidence. It seems that executives always find a way, whether in a hallway or elevator, to ask BCM professionals about the company's level of readiness. When asked, they must be ready with an informed response. The establishment of a process to measure business continuity programme performance and organisational readiness has emerged as a key component of US Department of Homeland Security 'Voluntary Private Sector Preparedness (PS-Prep) Program' standards where the overarching goal is to improve private sector preparedness for disasters and emergencies. The purpose of this paper is two-fold: to introduce continuity professionals to best practices that should be considered when developing a BCM metrics programme as well as providing a case study of how a large health insurance company researched, developed and implemented a process to measure BCM programme performance and company readiness.

  10. Interactions between cilazapril and propranolol in man; plasma drug concentrations, hormone and enzyme responses, haemodynamics, agonist dose-effect curves and baroreceptor reflex.

    PubMed Central

    Belz, G G; Essig, J; Kleinbloesem, C H; Hoogkamer, J F; Wiegand, U W; Wellstein, A

    1988-01-01

    1. The pharmacokinetics, hormonal and haemodynamic responses at rest and during challenges with angiotensin I (blood pressure), isoprenaline (heart rate), and noradrenaline (blood pressure) were investigated in six healthy male volunteers following a 1 week treatment with placebo, propranolol (120 mg day-1), cilazapril (2, 5 mg day-1), and a combination of both in a double-blind cross-over design. 2. Both drugs reduced systolic and diastolic blood pressure by about 7 mm Hg as compared with placebo. After coadministration, this drop in blood pressure was doubled and lasted longer than after the administration of the individual components. 3. Following cilazapril, a pronounced increase in plasma renin activity (PRA) was found (factor approximately 10 at drug peak concentrations). Coadministration of both drugs resulted only in a moderate increase in the PRA (factor approximately 3). Significant changes in plasma catecholamines were not observed. 4. Propranolol shifted the isoprenaline dose-effect curve to the right, and cilazapril that of angiotensin I, irrespective of the presence of the other drug. Cilazapril tended to shift the noradrenaline dose-effect curve somewhat to the right. 5. The gain of the baroreceptor reflex (angiotensin-stimulation) was not influenced by cilazapril but was lowered by propranolol, irrespective of the presence of the ACE inhibitor. 6. Except for a statistically not significant decrease in the peak concentrations of each drug during the combined therapy, a pharmacokinetic interaction between the two drugs was not found. PMID:2974715

  11. High-Precision Ionosphere Monitoring Using Continuous Measurements from BDS GEO Satellites

    PubMed Central

    Yang, Haiyan; Yang, Xuhai; Zhang, Zhe; Zhao, Kunjuan

    2018-01-01

    The current constellation of the BeiDou Navigation Satellite System (BDS) consists of five geostationary earth orbit (GEO) satellites, five inclined geosynchronous satellite orbit (IGSO) satellites, and four medium earth orbit (MEO) satellites. The advantage of using GEO satellites to monitor the ionosphereis the almost motionless ionospheric pierce point (IPP), which is analyzed in comparison with the MEO and IGSO satellites. The results from the analysis of the observations using eight tracking sites indicate that the ionospheric total electron content (TEC) sequence derived from each GEO satellite at their respective fixed IPPs is always continuous. The precision of calculated vertical TEC (VTEC) using BDS B1/B2, B1/B3, and B2/B3 dual-frequency combinationsis compared and analyzed. The VTEC12 precision based on the B1/B2 dual-frequency measurements using the smoothed code and the raw code combination is 0.69 and 5.54 TECU, respectively, which is slightly higher than VTEC13 and much higher than VTEC23. Furthermore, the ionospheric monitoring results of site JFNG in the northern hemisphere, and CUT0 in the southern hemisphere during the period from 1 January to 31 December 2015 are presented and discussed briefly. PMID:29495506

  12. High-Precision Ionosphere Monitoring Using Continuous Measurements from BDS GEO Satellites.

    PubMed

    Yang, Haiyan; Yang, Xuhai; Zhang, Zhe; Zhao, Kunjuan

    2018-02-27

    The current constellation of the BeiDou Navigation Satellite System (BDS) consists of five geostationary earth orbit (GEO) satellites, five inclined geosynchronous satellite orbit (IGSO) satellites, and four medium earth orbit (MEO) satellites. The advantage of using GEO satellites to monitor the ionosphereis the almost motionless ionospheric pierce point (IPP), which is analyzed in comparison with the MEO and IGSO satellites. The results from the analysis of the observations using eight tracking sites indicate that the ionospheric total electron content (TEC) sequence derived from each GEO satellite at their respective fixed IPPs is always continuous. The precision of calculated vertical TEC (VTEC) using BDS B1/B2, B1/B3, and B2/B3 dual-frequency combinationsis compared and analyzed. The VTEC 12 precision based on the B1/B2 dual-frequency measurements using the smoothed code and the raw code combination is 0.69 and 5.54 TECU, respectively, which is slightly higher than VTEC 13 and much higher than VTEC 23 . Furthermore, the ionospheric monitoring results of site JFNG in the northern hemisphere, and CUT0 in the southern hemisphere during the period from 1 January to 31 December 2015 are presented and discussed briefly.

  13. Continuous quantitative measurement of the proximal airway dimensions and lung density on four-dimensional dynamic-ventilation CT in smokers

    PubMed Central

    Yamashiro, Tsuneo; Moriya, Hiroshi; Tsubakimoto, Maho; Matsuoka, Shin; Murayama, Sadayuki

    2016-01-01

    Purpose Four-dimensional dynamic-ventilation computed tomography (CT) imaging demonstrates continuous movement of the airways and lungs, which cannot be depicted with conventional CT. We aimed to investigate continuous changes in lung density and airway dimensions and to assess the correlation with spirometric values in smokers. Materials and methods This retrospective study was approved by the Institutional Review Board, and informed consent was waived. Twenty-one smokers including six patients with COPD underwent four-dimensional dynamic-ventilation CT during free breathing (160 mm in length). The mean lung density (MLD) of the scanned lung and luminal areas (Ai) of fixed points in the trachea and the right proximal bronchi (main bronchus, upper bronchus, bronchus intermedius, and lower bronchus) were continuously measured. Concordance between the time curve of the MLD and that of the airway Ai values was expressed by cross-correlation coefficients. The associations between these quantitative measurements and the forced expiratory volume in 1 second/forced vital capacity (FEV1/FVC) values were assessed by Spearman’s rank correlation analysis. Results On the time curve for the MLD, the Δ-MLD1.05 values between the peak inspiratory frame to the later third frame (1.05 seconds later) were strongly correlated with the FEV1/FVC (ρ=0.76, P<0.0001). The cross-correlation coefficients between the airway Ai and MLD values were significantly correlated with the FEV1/FVC (ρ=−0.56 to −0.66, P<0.01), except for the right upper bronchus. This suggested that the synchrony between the airway and lung movement was lost in patients with severe airflow limitation. Conclusion Respiratory changes in the MLD and synchrony between the airway Ai and the MLD measured with dynamic-ventilation CT were correlated with patient’s spirometric values. PMID:27110108

  14. Fluid Dynamic Characterization of a Polymeric Heart Valve Prototype (Poli-Valve) tested under Continuous and Pulsatile Flow Conditions

    PubMed Central

    De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D.; Costantino, Maria Laura

    2016-01-01

    Introduction Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy, the latter display better fluid dynamic behaviour but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the haemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of two groups of newly developed supra-annular tri-leaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods Two types of Poli-Valves made of SBC differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. An ad - hoc designed pulse duplicator allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the valve’s behaviour. Results Both types Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by ISO 5840 Standard. Results were compared with five mechanical heart valves (MHVs) and five tissue heart valves (THVs), currently available on the market. Conclusion Based on these results, polymeric heart valves based on styrenic block copolymers, as Poli-Valves are, can be considered as promising alternative for heart valve replacement in near future. PMID:26689146

  15. Multicenter Study Validating Accuracy of a Continuous Respiratory Rate Measurement Derived From Pulse Oximetry: A Comparison With Capnography.

    PubMed

    Bergese, Sergio D; Mestek, Michael L; Kelley, Scott D; McIntyre, Robert; Uribe, Alberto A; Sethi, Rakesh; Watson, James N; Addison, Paul S

    2017-04-01

    Intermittent measurement of respiratory rate via observation is routine in many patient care settings. This approach has several inherent limitations that diminish the clinical utility of these measurements because it is intermittent, susceptible to human error, and requires clinical resources. As an alternative, a software application that derives continuous respiratory rate measurement from a standard pulse oximeter has been developed. We sought to determine the performance characteristics of this new technology by comparison with clinician-reviewed capnography waveforms in both healthy subjects and hospitalized patients in a low-acuity care setting. Two independent observational studies were conducted to validate the performance of the Medtronic Nellcor Respiration Rate Software application. One study enrolled 26 healthy volunteer subjects in a clinical laboratory, and a second multicenter study enrolled 53 hospitalized patients. During a 30-minute study period taking place while participants were breathing spontaneously, pulse oximeter and nasal/oral capnography waveforms were collected. Pulse oximeter waveforms were processed to determine respiratory rate via the Medtronic Nellcor Respiration Rate Software. Capnography waveforms reviewed by a clinician were used to determine the reference respiratory rate. A total of 23,243 paired observations between the pulse oximeter-derived respiratory rate and the capnography reference method were collected and examined. The mean reference-based respiratory rate was 15.3 ± 4.3 breaths per minute with a range of 4 to 34 breaths per minute. The Pearson correlation coefficient between the Medtronic Nellcor Respiration Rate Software values and the capnography reference respiratory rate is reported as a linear correlation, R, as 0.92 ± 0.02 (P < .001), whereas Lin's concordance correlation coefficient indicates an overall agreement of 0.85 ± 0.04 (95% confidence interval [CI] +0.76; +0.93) (healthy volunteers: 0.94 ± 0

  16. The effect of adaptive servo-ventilation on dyspnoea, haemodynamic parameters and plasma catecholamine concentrations in acute cardiogenic pulmonary oedema.

    PubMed

    Nakano, Shintaro; Kasai, Takatoshi; Tanno, Jun; Sugi, Keiki; Sekine, Yasumasa; Muramatsu, Toshihiro; Senbonmatsu, Takaaki; Nishimura, Shigeyuki

    2015-08-01

    Adaptive servo-ventilation has a potential sympathoinhibitory effect in acute cardiogenic pulmonary oedema (ACPO). To evaluate the acute effects of adaptive servo-ventilation in patients with ACPO. Fifty-eight consecutive patients with ACPO were divided into those who underwent adaptive servo-ventilation and those who received oxygen therapy alone as part of their immediate care. Visual analogue scale, vital signs, blood gas data and plasma catecholamine concentrations at baseline and 1 h during emergency care, and subsequent clinical events (death within 30 days, intubation within seven days or between seven and 30 days, and length of hospital stay) were assessed. Pre-matched and post-propensity score (PS)-matched datasets were analysed. During the first hour of adaptive servo-ventilation, plasma catecholamine concentrations fell significantly (baseline versus 1 h: epinephrine p = 0.003, norepinephrine p < 0.001, dopamine p < 0.001), with falls in blood pressure, heart rate, respiratory rate and pCO2, and rise in HCO3 and pH. In the PS-matched model, visual analogue scale (p = 0.036), systolic blood pressure (from 153.8 ± 30.7 to 133.1 ± 16.3 mmHg; p = 0.025) and plasma dopamine concentration (p = 0.034) fell significantly in the adaptive servo-ventilation group compared with the oxygen therapy alone group. The clinical outcomes between the groups were comparable. In patients with ACPO, emergency care using adaptive servo-ventilation attenuated plasma catecholamine concentrations and led to the improvement of dyspnoea, vital signs and acid-base balance, without adversely influencing clinical outcomes. Using adaptive servo-ventilation, rather than standard oxygen alone, may relieve dyspnoea and improve haemodynamic status, possibly by modulating sympathetic nerve activity. © The European Society of Cardiology 2014.

  17. Left ventricular mechanics in humans with high aerobic fitness: adaptation independent of structural remodelling, arterial haemodynamics and heart rate

    PubMed Central

    Stöhr, Eric J; McDonnell, Barry; Thompson, Jane; Stone, Keeron; Bull, Tom; Houston, Rory; Cockcroft, John; Shave, Rob

    2012-01-01

    Individuals with high aerobic fitness have lower systolic left ventricular strain, rotation and twist (‘left ventricular (LV) mechanics’) at rest, suggesting a beneficial reduction in LV myofibre stress and more efficient systolic function. However, the mechanisms responsible for this functional adaptation are not known and the influence of aerobic fitness on LV mechanics during dynamic exercise has never been studied. We assessed LV mechanics, LV wall thickness and dimensions, central augmentation index (AIx), aortic pulse wave velocity (aPWV), blood pressure and heart rate in 28 males (age: 21 ± 2 years SD) with a consistent physical activity level (no change >6 months). Individuals were examined at rest and during exercise (40% peak exercise capacity) and separated post hoc into a moderate and high aerobic fitness group (: 49 ± 5 and 63 ± 7 ml kg−1 min−1, respectively, P < 0.0001). At rest and during exercise, there were no significant differences in gross LV structure, AIx, blood pressure or heart rate (P > 0.05). However, for the same AIx, the high group had significantly lower LV apical rotation (P = 0.002) and LV twist (P = 0.003) while basal rotation and strain indices did not differ between groups (P > 0.05). We conclude that young males with high aerobic fitness have lower LV apical rotation at rest and during submaximal exercise that can occur without changes in gross LV structure, arterial haemodynamics or heart rate. The findings suggest a previously unknown type of physiological adaptation of the left ventricle that may have important implications for exercise training in older individuals and patient populations in which exercise training has previously failed to show clear benefits for LV function. PMID:22431336

  18. RV stroke work in children with pulmonary arterial hypertension: estimation based on invasive haemodynamic assessment and correlation with outcomes.

    PubMed

    Di Maria, Michael V; Younoszai, Adel K; Mertens, Luc; Landeck, Bruce F; Ivy, D Dunbar; Hunter, Kendall S; Friedberg, Mark K

    2014-09-01

    RV performance is an important determinant of outcomes in children with pulmonary arterial hypertension (PAH). RV stroke work (RVSW), the product of mean pulmonary artery pressure and stroke volume, integrates contractility, afterload and ventricular-vascular coupling. RVSW has not been evaluated in children with PAH. We tested the hypothesis that RVSW would be a predictor of outcomes in children with PAH. Patients in the Children's Hospital Colorado PAH database were evaluated retrospectively, and those with idiopathic PAH and those with minor or repaired congenital heart disease were included. Haemodynamic data were obtained by catheterisation and echocardiography, performed within 3 months. RVSW was calculated: mean pulmonary arterial pressure × stroke volume, and indexed to body surface area. Statistics included Kruskal-Wallis, Wilcoxon rank sum, and Spearman correlation. Fifty patients were included. Median age of the cohort was 9.5 (6.0, 15.7) years, with a median indexed pulmonary vascular resistance (PVRi) of 6.5 (3.7, 11.6) WU m(2). RVSW had a significant association with PVRi (r=0.6, p<0.0001), tricuspid annular systolic plane excursion (r=0.55, p=0.0001), and RV fractional area change (r=-0.4, p=0.005). Grouped by WHO class, there was a significant difference in RVSW (p=0.04). Need for atrial septostomy and death were associated with higher RVSW (p=0.04 and p=0.03, respectively). RVSW can be estimated in children with PAH, and is significantly associated with abnormal WHO class, the need for septostomy, as well as mortality. Indices accounting for RV performance as well as ventricular-vascular coupling may be useful in the prognosis and, hence, management of children with PAH. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Prospect of Continuous VLBI Measurement of Earth Rotation in Monitoring Geophysical Fluids

    NASA Technical Reports Server (NTRS)

    Chao, Benjamin F.; Ma, Chopo; Clark, Thomas

    1998-01-01

    Large-scale mass transports in the geophysical fluids of the Earth system excite Earth's rotational variations in both length-of-day and polar motion. The excitation process is via the conservation of angular momentum. Therefore Earth rotation observations contain information about the integrated angular momentum (consisting of both the mass term and the motion term) of the geophysical fluids, which include atmosphere, hydrosphere, mantle, and the outer and inner cores. Such global information is often important and otherwise unattainable depending on the nature of the mass transport, its magnitude and time scale. The last few years have seen great advances in VLBI measurement of Earth rotation in precision and temporal resolution. These advances have opened new. areas in geophysical fluid studies, such as oceanic tidal angular momentum, atmospheric tides, Earth librations, and rapid atmospheric angular momentum fluctuations. Precision of 10 microseconds in UTI and 200 microarcseconds in polar motion can now be achieved on hourly basis. Building upon this heritage, the multi-network geodetic VLBI project, Continuous Observation of the Rotation of the Earth (CORE), promises to further these studies and to make possible studies on elusive but tell-tale geophysical processes such as oscillatory modes in the core and in the atmosphere. Currently the early phase of CORE is underway. Within a few years into the new mellinnium, the upcoming space gravity missions (such as GRACE) will measure the temporal variations in Earth's gravitational field, thus providing complementary information to that from Earth rotation study for a better understanding of global geophysical fluid processes.

  20. Coded continuous wave meteor radar

    NASA Astrophysics Data System (ADS)

    Chau, J. L.; Vierinen, J.; Pfeffer, N.; Clahsen, M.; Stober, G.

    2016-12-01

    The concept of a coded continuous wave specular meteor radar (SMR) is described. The radar uses a continuously transmitted pseudorandom phase-modulated waveform, which has several advantages compared to conventional pulsed SMRs. The coding avoids range and Doppler aliasing, which are in some cases problematic with pulsed radars. Continuous transmissions maximize pulse compression gain, allowing operation at lower peak power than a pulsed system. With continuous coding, the temporal and spectral resolution are not dependent on the transmit waveform and they can be fairly flexibly changed after performing a measurement. The low signal-to-noise ratio before pulse compression, combined with independent pseudorandom transmit waveforms, allows multiple geographically separated transmitters to be used in the same frequency band simultaneously without significantly interfering with each other. Because the same frequency band can be used by multiple transmitters, the same interferometric receiver antennas can be used to receive multiple transmitters at the same time. The principles of the signal processing are discussed, in addition to discussion of several practical ways to increase computation speed, and how to optimally detect meteor echoes. Measurements from a campaign performed with a coded continuous wave SMR are shown and compared with two standard pulsed SMR measurements. The type of meteor radar described in this paper would be suited for use in a large-scale multi-static network of meteor radar transmitters and receivers. Such a system would be useful for increasing the number of meteor detections to obtain improved meteor radar data products, such as wind fields. This type of a radar would also be useful for over-the-horizon radar, ionosondes, and observations of field-aligned-irregularities.