Sample records for haemodynamics coagulation acid-base

  1. Study of coagulation processes of selected humic acids under copper ions influence*

    NASA Astrophysics Data System (ADS)

    Boguta, Patrycja; Sokolowska, Zofia

    2013-04-01

    (carbon analyzer: Multi NC2000, Analityk Jena) and measurements of copper content in solution (atomic absorption spectrometer: Contraa300, Analityk Jena). On the base of obtained results initial and end point of coagulation was determined for each of humic acids. Results showed that coagulation points differed for different humic acids and it was probably depended on sorption possibilities. Coagulation points determined from UV-VIS measurements overlapped with points from carbon measurement. Loss of carbon during coagulation was almost total but loss of copper in solution during humic acid coagulation was much smaller and did not cover exactly points of carbon precipitation. So that, coagulation of humic acids under copper influence could resulted from both bonding of metal by functional groups and creating complexes and also from increasing ionic strength. Important is that organic carbon went to insoluble form and copper stayed in movable compounds. Such studies and conclusions coming from them, can be very important from ecological side. *This work was partly supported by the National Science Centre in Poland, grant No. UMO-2011/03/N/NZ9/04239.

  2. Short communication: Prediction of milk coagulation and acidity traits in Mediterranean buffalo milk using Fourier-transform mid-infrared spectroscopy.

    PubMed

    Manuelian, C L; Visentin, G; Boselli, C; Giangolini, G; Cassandro, M; De Marchi, M

    2017-09-01

    Milk coagulation and acidity traits are important factors to inform the cheesemaking process. Those traits have been deeply studied in bovine milk, whereas scarce information is available for buffalo milk. However, the dairy industry is interested in a method to determine milk coagulation and acidity features quickly and in a cost-effective manner, which could be provided by Fourier-transform mid-infrared (FT-MIR) spectroscopy. The aim of this study was to evaluate the potential of FT-MIR to predict coagulation and acidity traits of Mediterranean buffalo milk. A total of 654 records from 36 herds located in central Italy with information on milk yield, somatic cell score, milk chemical composition, milk acidity [pH, titratable acidity (TA)], and milk coagulation properties (rennet coagulation time, curd firming time, and curd firmness) were available for statistical analysis. Reference measures of milk acidity and coagulation properties were matched with milk spectral information, and FT-MIR prediction models were built using partial least squares regression. The data set was divided into a calibration set (75%) and a validation set (25%). The capacity of FT-MIR spectroscopy to correctly classify milk samples based on their renneting ability was evaluated by a canonical discriminant analysis. Average values for milk coagulation traits were 13.32 min, 3.24 min, and 39.27 mm for rennet coagulation time, curd firming time, and curd firmness, respectively. Milk acidity traits averaged 6.66 (pH) and 7.22 Soxhlet-Henkel degrees/100 mL (TA). All milk coagulation and acidity traits, except for pH, had high variability (17 to 46%). Prediction models of coagulation traits were moderately to scarcely accurate, whereas the coefficients of determination of external validation were 0.76 and 0.66 for pH and TA, respectively. Canonical discriminant analysis indicated that information on milk coagulating ability is present in the MIR spectra, and the model correctly classified as

  3. Should anti-inhibitor coagulant complex and tranexamic acid be used concomitantly?

    PubMed

    Valentino, L A; Holme, P A

    2015-11-01

    Inhibitor development in haemophilia patients is challenging especially when undergoing surgical procedures. The development of an inhibitor precludes using factor VIII (FVIII) therapy thereby requiring a bypassing agent (BPA) for surgical bleeding prophylaxis if the FVIII inhibitor titre >5 BU. Concomitant use of anti-inhibitor coagulant complex (AICC) and tranexamic acid has been reported in the literature as a beneficial treatment for this population. Anti-inhibitor coagulant complex is known to cause an increase in thrombin generation and tranexamic acid inhibits fibrinolysis. Hence, the combined used of AICC and tranexamic acid has been limited due to safety concerns over possibilities of increased risk of thrombotic events and disseminated intravascular coagulation. However, the rationale for concomitant therapy is to obtain a potential synergistic effect and to increase clot stability. We conducted a literature review of past studies and individual case reports of concomitant use of AICC and tranexamic acid, which was extensively used during dental procedures. Evidence also exists for concomitant use of the combined therapy in orthopaedic procedures, control of gastrointestinal bleeding, epistaxis and cerebral haemorrhages. Some patients who received the combined therapy had failed monotherapy with a single BPA prior to combined therapy. There were no reports of thrombotic complications related to the concomitant therapy and haemostasis was achieved in all cases. Anti-inhibitor coagulant complex and tranexamic acid therapy was found to be safe, well-tolerated and effective therapy in haemophilia patients with inhibitors. Additional randomized controlled studies should be performed to confirm these findings. © 2015 John Wiley & Sons Ltd.

  4. Effects of alum coagulation on speciation and distribution of trihalomethanes (THMs) and haloacetic acids (HAAs).

    PubMed

    Gang, Dianchen; Clevenger, Thomas E; Banerji, Shankha K

    2005-01-01

    The impacts of alum coagulation on the distribution of disinfection by-products (DBPs), trihalomethanes (THMs), and haloacetic acids (HAAs) were evaluated under controlled chlorination conditions using four surface waters. Among the nine HAAs found in waters, dihaloacetic acids (X2AAs) have been found to be the dominant species in all of the raw and alum treated waters. Alum coagulation tends to remove more monohaloacetic acids (XAAs) and trihaloacetic acids (X3AAs) precursors than that of dihaloacetic acids (X2AAs). Alum coagulation treated water had a lower HAA9/TTHM ratio compared with that of the raw water. The increase of THM bromine incorporation factors (BIFalpha) value of alum treated water was statistically significant in comparison with the raw water. On average, BIFalpha increased by 54% after the alum coagulation process in these four different waters. This indicated that THM speciations shifted in favor of the more brominated compounds. However, alum coagulation treatment process had less effect on HAA bromi ne incorporation factors (BIFbeta)than it did on BIFalpha. Bromine incorporation factor (BIF) values decreased with time in the THM and HAA formation processes, especially within the first 10 h of the reaction time. This suggested that brominated THMs or HAAs formed faster than the chlorinated species in the initial period.

  5. C-1s NEXAFS spectroscopy reveals chemical fractionation of humic acid by cation-induced coagulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christl,I.; Kretzschmar, R.

    2007-01-01

    The influence of cation-induced coagulation on the chemical composition of dissolved and coagulated fractions of humic acid was investigated in batch coagulation experiments for additions of aluminum at pH 4 and 5, iron at pH 4, and calcium and lead at pH 6. The partitioning of organic carbon and metals was determined by analyzing total organic carbon and total metal contents of the dissolved phase. Both the dissolved and the coagulated humic acid fractions were characterized using synchrotron scanning transmission X-ray microscopy (STXM) and C-1s near-edge X-ray absorption fine structure (NEXAFS) spectroscopy. Intensities of {pi}* transitions of carboxyl carbon andmore » {sigma}* transitions of alkyl, O-alkyl, and carboxyl carbon decreased with increasing metal concentration for the dissolved humic acid fractions. This decrease was accompanied by an increase of the respective intensities in the coagulated fraction as shown for lead. Intensities of aromatic and phenolic carbon were affected to a larger extent only by aluminum and iron additions. The changes observed in the C-1s NEXAFS spectra coincided with an increasing removal of organic carbon from the dissolved phase with increasing total metal concentrations. We conclude that humic acid was chemically fractionated by cation-induced coagulation, which preferentially removed functional groups involved in metal-cation binding from solution.« less

  6. Enhanced algae removal by Ti-based coagulant: comparison with conventional Al- and Fe-based coagulants.

    PubMed

    Xu, Jie; Zhao, Yanxia; Gao, Baoyu; Zhao, Qian

    2018-05-01

    The water eutrophication caused by cyanobacteria seasonally proliferates, which is a hot potato to be resolved for water treatment plants. This study firstly investigated coagulation performance of titanium tetrachloride (TiCl 4 ) for Microcystis aeruginosa synthetic water treatment. Results show complete algal cell removal by TiCl 4 coagulation without damage to cell membrane integrity even under harsh conditions; 60 mg/L TiCl 4 was effective in removing the microcystins up to 85%. Furthermore, besides having stronger UV 254 removal capability and the higher removal of fluorescent substances over Al- and Fe-based coagulants, TiCl 4 coagulant required more compact coagulation and sedimentation tanks due to its significantly improved floc growth and sedimentation speed. Meanwhile, its' short hydraulic retention time avoided algal cell breakage and subsequent algal organic matter release. Microcystin concentrations were kept at a low level during sludge storage period, indicating that the TiCl 4 flocs could prevent algal cells from natural lysis. To facilitate water recycling without secondary contamination, the algae-containing sludge after TiCl 4 coagulation ought to be disposed within 12 days at 20 °C and 8 days at 35 °C.

  7. Evaluation of plant-based natural coagulants for municipal wastewater treatment.

    PubMed

    Maurya, Sandhya; Daverey, Achlesh

    2018-01-01

    In this study, four plant-based natural coagulants (banana peel powder, banana stem juice, papaya seed powder and neem leaf powder) were evaluated for the removal of turbidity, chemical oxygen demand (COD) and total suspended solids (TSS) from municipal wastewater. The experiments were conducted at room temperature without adjusting the initial pH. The maximum turbidity removal was observed with banana peel powder (59.6%) at 0.4 g/L of dosage. Papaya seed powder and banana stem juice were the most effective for TSS removal (66.66%) and COD removal (66.67%), respectively. Significant linear relationships between turbidity and TSS ( R 2  = 0.67-0.88) and turbidity removals and COD removals ( R 2  = 0.68-0.8) were observed. Interestingly, all the natural coagulants tested in the study did not change the pH of the wastewater, which is an added advantage. FTIR analysis of banana peels revealed that functional groups such as carboxylic acid, hydroxyl and aliphatic amines might be responsible for promoting the coagulation-flocculation by neutralizing the charge on impurities in water. Overall, the results suggest the potential of low-cost natural coagulants in municipal wastewater treatment.

  8. Genetic parameters of coagulation properties, milk yield, quality, and acidity estimated using coagulating and noncoagulating milk information in Brown Swiss and Holstein-Friesian cows.

    PubMed

    Cecchinato, A; Penasa, M; De Marchi, M; Gallo, L; Bittante, G; Carnier, P

    2011-08-01

    The aim of this study was to estimate heritabilities of rennet coagulation time (RCT) and curd firmness (a(30)) and their genetic correlations with test-day milk yield, composition (fat, protein, and casein content), somatic cell score, and acidity (pH and titratable acidity) using coagulating and noncoagulating (NC) milk information. Data were from 1,025 Holstein-Friesian (HF) and 1,234 Brown Swiss (BS) cows, which were progeny of 54 HF and 58 BS artificial insemination sires, respectively. Milk coagulation properties (MCP) of each cow were measured once using a computerized renneting meter and samples not exhibiting coagulation within 31 min after rennet addition were classified as NC milk. For NC samples, RCT was unobserved. Multivariate analyses, using Bayesian methodology, were performed to estimate the genetic relationships of RCT or a(30) with the other traits and statistical inference was based on the marginal posterior distributions of parameters of concern. For analyses involving RCT, a right-censored Gaussian linear model was used and records of NC milk samples, being censored records, were included as unknown parameters in the model implementing a data augmentation procedure. Rennet coagulation time was more heritable [heritability (h(2))=0.240 and h(2)=0.210 for HF and BS, respectively] than a(30) (h(2)=0.148 and h(2)=0.168 for HF and BS, respectively). Milk coagulation properties were more heritable than a single test-day milk yield (h(2)=0.103 and h(2)=0.097 for HF and BS, respectively) and less heritable than milk composition traits whose heritability ranged from 0.275 to 0.275, with the only exception of fat content of BS milk (h(2)=0.108). A negative genetic correlation, lower than -0.85, was estimated between RCT and a(30) for both breeds. Genetic relationships of MCP with yield and composition were low or moderate and favorable. The genetic correlation of somatic cell score with RCT in BS cows was large and positive and even more positive were

  9. Treatment of Arctic wastewater by chemical coagulation, UV and peracetic acid disinfection.

    PubMed

    Chhetri, Ravi Kumar; Klupsch, Ewa; Andersen, Henrik Rasmus; Jensen, Pernille Erland

    2017-02-16

    Conventional wastewater treatment is challenging in the Arctic region due to the cold climate and scattered population. Thus, no wastewater treatment plant exists in Greenland, and raw wastewater is discharged directly to nearby waterbodies without treatment. We investigated the efficiency of physicochemical wastewater treatment, in Kangerlussuaq, Greenland. Raw wastewater from Kangerlussuaq was treated by chemical coagulation and UV disinfection. By applying 7.5 mg Al/L polyaluminium chloride (PAX XL100), 73% of turbidity and 28% phosphate was removed from raw wastewater. E. coli and Enterococcus were removed by 4 and 2.5 log, respectively, when UV irradiation of 0.70 kWh/m 3 was applied to coagulated wastewater. Furthermore, coagulated raw wastewater in Denmark, which has a chemical quality similar to Greenlandic wastewater, was disinfected by peracetic acid or UV irradiation. Removal of heterotrophic bacteria by applying 6 and 12 mg/L peracetic acid was 2.8 and 3.1 log, respectively. Similarly, removal of heterotrophic bacteria by applying 0.21 and 2.10 kWh/m 3 for UV irradiation was 2.1 and greater than 4 log, respectively. Physicochemical treatment of raw wastewater followed by UV irradiation and/or peracetic acid disinfection showed the potential for treatment of arctic wastewater.

  10. Coagulant properties of Moringa oleifera protein preparations: application to humic acid removal.

    PubMed

    Santos, Andréa F S; Paiva, Patrícia M G; Teixeira, José A C; Brito, António G; Coelho, Luana C B B; Nogueira, Regina

    2012-01-01

    This work aimed to characterize the coagulant properties of protein preparations from Moringa oleifera seeds in the removal of humic acids from water. Three distinct preparations were assayed, namely extract (seeds homogenized with 0.15 M NaCl), fraction (extract precipitated with 60% w/v ammonium sulphate) and cMoL (protein purified with guar gel column chromatography). The extract showed the highest coagulant activity in a protein concentration between 1 mg/L and 180 mg/L at pH 7.0. The zeta potential of the extract (-10 mV to -15 mV) was less negative than that of the humic acid (-41 mV to -42 mV) in a pH range between 5.0 and 8.0; thus, the mechanism that might be involved in this coagulation activity is adsorption and neutralization of charges. Reduction of total organic carbon (TOC) and dissolved organic carbon (DOC) was observed in water samples containing 9 mg/L carbon as humic acid when treated with 1 mg/L of the extract. A decrease in colour and in the aromatic content of the treated water was also observed. These results suggested that the extract from M. oleifera seeds in a low concentration (1 mg/L) can be an interesting natural alternative for removing humic acid from water in developing countries. The extract dose determined in the present study does not impart odour or colour to the treated water.

  11. Coagulation profile of Sudanese children with homozygous sickle cell disease and the effect of treatment with omega-3 fatty acid on the coagulation parameters.

    PubMed

    Awoda, Shiekh; Daak, Ahmed A; Husain, Nazik Elmalaika; Ghebremeskel, Kebreab; Elbashir, Mustafa I

    2017-01-01

    It has been reported that patients with SCD do have an abnormal coagulation profile. Coagulopathy is thought to be one of the key factors that contribute to the vaso-occlusive crisis that characterises sickle cell disease (SCD). In this study, we investigated whether Sudanese sickle cell patients have an abnormal coagulation profile. In addition, the effect of treatment with either omega-3 fatty acids or hydroxyurea on coagulation profile was assessed. Homozygous SCD patients untreated ( n  = 52), omega-3 treated ( n  = 44), hydroxyurea (HU) treated ( n  = 8) and healthy (HbAA) controls ( n  = 52) matched for age (4-20 years), gender and socioeconomic status were enrolled. Patients on omega-3 fatty acids, according to age, received one to four capsules containing 277.8 mg DHA and 39.0 mg eicosapentnoic. Patients on Hydroxyurea were in on dosage more than 20 mg/kg/day. The steady state levels of the coagulation parameters and the effect of the treatments with either HU or omega-3 fatty acids on markers of coagulation were investigated. Compared to the healthy controls, treated and untreated HbSS patients had lower hemoglobin, plasma Protein C, proteins S and higher white blood cell count (WBC), platelets count (PLTs) and plasma D-dimer levels,( p  < 0.05). In comparison to untreated HbSS, treatment with neither omega-3 nor HU had effect on the WBC, plasma proteins C and S, ( p  > 0.05). HU treated group had a lower PLTs count compared to HbSS untreated group ( p  < 0.5). The prothrombin and activated partial thromboplastin times and international normalized ratio (INR) of untreated patients are significantly higher than n-3 treated, HU-treated patients and health controls, ( p  < 0.05). Patients treated with omega-3 had lowered D-dimer levels in comparison to HU-treated and untreated HbSS patients, ( p  < 0.001). This study provides evidence that Sudanes patients have abnormal coagulation profile and treatment with either HU or omega-3 fatty

  12. Comparative study of humic acid removal and floc characteristics by electrocoagulation and chemical coagulation.

    PubMed

    Semerjian, Lucy; Damaj, Ahmad; Salam, Darine

    2015-11-01

    The current study aims at investigating the efficiency of electrocoagulation for the removal of humic acid from contaminated waters. In parallel, conventional chemical coagulation was conducted to asses humic acid removal patterns. The effect of varying contributing parameters (matrix pH, humic acid concentration, type of electrode (aluminum vs. iron), current density, solution conductivity, and distance between electrodes) was considered to optimize the electrocoagulation process for the best attainable humic acid removal efficiencies. Optimum removals were recorded at pH of 5.0-5.5, an electrical conductivity of 3000 μS/cm at 25 °C, and an electrode distance of 1 cm for both electrode types. With aluminum electrodes, a current density of 0.05 mA/cm2 outperformed 0.1 mA/cm2 yet not higher densities, whereas a current density of 0.8 mA/cm2 was needed for iron electrodes to exhibit comparable performance. With both electrode types, higher initial humic acid concentrations were removed at a slower rate but ultimately attained almost complete removals. On the other hand, the best humic acid removals (∼90%) by chemical coagulation were achieved at 4 mg/L for both coagulants. Also, higher removals were attained at elevated initial humic acid concentrations. Humic acid removals of 90% or higher at an initial HA concentration of 40 mg/L were exhibited, yet alum performed better at the highest experimented concentration. It was evident that iron flocs were larger, denser, and more geometrical in shape compared to aluminum flocs.

  13. Applying the cell-based coagulation model in the management of critical bleeding.

    PubMed

    Ho, K M; Pavey, W

    2017-03-01

    The cell-based coagulation model was proposed 15 years ago, yet has not been applied commonly in the management of critical bleeding. Nevertheless, this alternative model may better explain the physiological basis of current coagulation management during critical bleeding. In this article we describe the limitations of the traditional coagulation protein cascade and standard coagulation tests, and explain the potential advantages of applying the cell-based model in current coagulation management strategies. The cell-based coagulation model builds on the traditional coagulation model and explains many recent clinical observations and research findings related to critical bleeding unexplained by the traditional model, including the encouraging results of using empirical 1:1:1 fresh frozen plasma:platelets:red blood cells transfusion strategy, and the use of viscoelastic and platelet function tests in patients with critical bleeding. From a practical perspective, applying the cell-based coagulation model also explains why new direct oral anticoagulants are effective systemic anticoagulants even without affecting activated partial thromboplastin time or the International Normalized Ratio in a dose-related fashion. The cell-based coagulation model represents the most cohesive scientific framework on which we can understand and manage coagulation during critical bleeding.

  14. Enhanced Coagulation-Flocculation Performance of Iron-Based Coagulants: Effects of PO4 3- and SiO3 2- Modifiers

    PubMed Central

    Teng, Houkai; Wang, Yili; Zhang, Yuxin; Zhao, Chuanliang; Liao, Yong

    2015-01-01

    PO4 3- and SiO3 2- are often used as modifier to improve stability and aggregating ability of the iron-base coagulants, however, there are few reports about their detailed comparison between the coagulation performance and mechanisms. In this study, three coagulants—polyferric phosphoric sulfate (PFPS), polysilicon ferric sulfate (PFSS), and polyferric sulfate (PFS) were synthesized; their structure and morphology were characterized by Fourier transformed infrared (FT-IR) spectroscopy, X-ray diffraction (XRD) and Scanning electron microscope (SEM). Alkali titration and Ferron species analysis were employed to investigate the hydrolysis performance and species distribution. Jar test was conducted to measure their coagulation behaviors at different dosage, pH, and temperatures in which the flocs properties were measured. The results showed that a number of new compounds were formed due to the presence of PO4 3- and SiO3 2-. Moreover, PFPS and PFSS had similar level in Fea as well as Feb. Among them, PFPS produced more multi-core iron atoms polymer and content of Feb, and the formed flocs were larger and denser. It exhibited superior coagulation performance in terms of turbidity reduction, UV254 removal and residual ferric concentration. Jar test and floc breakage/regrowth experiments indicated other than charge neutrality, the dominated mechanism involved in PFSS was the adsorption between polysilicic acid and solution particle, while PFPS was sweeping, entrapment/adsorption resulting from larger polymer colloid of Fe-P chemistry bond. PMID:26339902

  15. Effects of tranexamic acid on coagulation indexes of patients undergoing heart valve replacement surgery under cardiopulmonary bypass

    PubMed Central

    Liu, Fei; Xu, Dong; Zhang, Kefeng; Zhang, Jian

    2016-01-01

    This study aims to explore the effects of tranexamic acid on the coagulation indexes of patients undergoing heart valve replacement surgery under the condition of cardiopulmonary bypass (CPB). One hundred patients who conformed to the inclusive criteria were selected and divided into a tranexamic acid group and a non-tranexamic acid group. They all underwent heart valve replacement surgery under CPB. Patients in the tranexamic acid group were intravenously injected with 1 g of tranexamic acid (100 mL) at the time point after anesthesia induction and before skin incision and at the time point after the neutralization of heparin. Patients in the non-tranexamic acid group were given 100 mL of normal saline at corresponding time points, respectively. Then the coagulation indexes of the two groups were analyzed. The activated blood clotting time (ACT) of the two groups was within normal scope before CPB, while four coagulation indexes including prothrombin time (PT), activated partial thromboplastin time (APTT), international normalized ratio (INR), and fibrinogen (FIB) had significant increases after surgery; the PT and INR of the tranexamic acid group had a remarkable decline after surgery. All the findings suggest that the application of tranexamic acid in heart valve replacement surgery under CPB can effectively reduce intraoperative and postoperative blood loss. PMID:27694613

  16. Selective binding behavior of humic acid removal by aluminum coagulation.

    PubMed

    Jin, Pengkang; Song, Jina; Yang, Lei; Jin, Xin; Wang, Xiaochang C

    2018-02-01

    The reactivity characteristics of humic acid (HA) with aluminium coagulants at different pH values was investigated. It revealed that the linear complexation reaction occurred between aluminum and humic acid at pH < 7, and the reaction rate increased as the pH increased from 2 to 6. While at pH = 7, most of the dosed aluminum existed in the form of free aluminum and remained unreacted in the presence of HA until the concentration reached to trigger Al(OH) 3(s) formation. Differentiating the change of functional groups of HA by 1 H nuclear magnetic resonance spectroscopy and X-ray photoelectron spectra analysis, it elucidated that there was a selective complexation between HA and Al with lower Al dosage at pH 5, which was probably due to coordination of the activated functional groups onto aluminium. While almost all components were removed proportionally by sweep adsorption without selectivity at pH 7, as well as that with higher Al dosage at pH 5. This study provided a promising pathway to analyse the mechanism of the interaction between HA and metal coagulants in future. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Perioperative goal-directed haemodynamic therapy based on flow parameters: a concept in evolution.

    PubMed

    Meng, L; Heerdt, P M

    2016-12-01

    Haemodynamic management incorporating direct or surrogate stroke volume monitoring has experienced a rapid evolution, because of emergence of the "goal-directed therapy" concept and technological developments aimed at providing a parameter leading to the goal. Nonetheless, consensus on both definitions of the ideal "goal" and strategies for achieving it remain elusive. For this review, we first consider basic physiological and patient monitoring factors relevant to the concept of "fluid responsiveness", and then focus upon randomized controlled trials and meta-analyses involving goal-directed haemodynamic therapy based on various flow parameters. Finally, we discuss the current status of noninvasive methods for monitoring fluid responsiveness. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Effects of tranexamic acid on coagulation indexes of patients undergoing heart valve replacement surgery under cardiopulmonary bypass.

    PubMed

    Liu, Fei; Xu, Dong; Zhang, Kefeng; Zhang, Jian

    2016-12-01

    This study aims to explore the effects of tranexamic acid on the coagulation indexes of patients undergoing heart valve replacement surgery under the condition of cardiopulmonary bypass (CPB). One hundred patients who conformed to the inclusive criteria were selected and divided into a tranexamic acid group and a non-tranexamic acid group. They all underwent heart valve replacement surgery under CPB. Patients in the tranexamic acid group were intravenously injected with 1 g of tranexamic acid (100 mL) at the time point after anesthesia induction and before skin incision and at the time point after the neutralization of heparin. Patients in the non-tranexamic acid group were given 100 mL of normal saline at corresponding time points, respectively. Then the coagulation indexes of the two groups were analyzed. The activated blood clotting time (ACT) of the two groups was within normal scope before CPB, while four coagulation indexes including prothrombin time (PT), activated partial thromboplastin time (APTT), international normalized ratio (INR), and fibrinogen (FIB) had significant increases after surgery; the PT and INR of the tranexamic acid group had a remarkable decline after surgery. All the findings suggest that the application of tranexamic acid in heart valve replacement surgery under CPB can effectively reduce intraoperative and postoperative blood loss. © The Author(s) 2016.

  19. Two-dimensional correlation spectroscopic analysis on the interaction between humic acids and aluminum coagulant.

    PubMed

    Jin, Pengkang; Song, Jina; Wang, Xiaochang C; Jin, Xin

    2018-02-01

    In this study, two-dimensional correlation spectroscopy integrated with synchronous fluorescence and infrared absorption spectroscopy was employed to investigate the interaction between humic acids and aluminum coagulant at slightly acidic and neutral pH. Higher fluorescence quenching was produced for fulvic-like and humic-like fractions at pH5. At pH5, the humic-like fractions originating from the carboxylic acid, carboxyl and polysaccharide compounds were bound to aluminum first, followed by the fulvic-like fractions originating from the carboxyl and polysaccharide compounds. This finding also demonstrated that the activated functional groups of HA were involved in forming the Al-HA complex, which was accompanied by the removal of other groups by co-precipitation. Meanwhile, at pH7, almost no fluorescence quenching occurred, and surface complexation was observed to occur, in which the activated functional groups were absorbed on the amorphous Al(OH) 3 . Two-dimensional FT-IR correlation spectroscopy indicated the sequence of HA structural change during coagulation with aluminum, with IR bands affected in the order of COOH>COO - >NH deformation of amide II>aliphatic hydroxyl COH at pH5, and COO - >aliphatic hydroxyl COH at pH7. This study provides a promising pathway for analysis and insight into the priority of functional groups in the interaction between organic matters and metal coagulants. Copyright © 2017. Published by Elsevier B.V.

  20. Fat high in stearic acid favorably affects blood lipids and factor VII coagulant activity in comparison with fats high in palmitic acid or high in myristic and lauric acids.

    PubMed

    Tholstrup, T; Marckmann, P; Jespersen, J; Sandström, B

    1994-02-01

    The effect of fats high in individual, prevalent saturated dietary fatty acids on lipoproteins and hemostatic variables in young healthy subjects was evaluated in a randomized strictly controlled metabolic feeding study. Three experimental diets: shea butter (S; 42% stearic acid), palm oil (P; 43% palmitic palmitic acid), and palm-kernel oil with high-oleic sunflower oil (ML; 10% myristic acid, 30% lauric acid) were served to 15 men for 3 wk each, separated by washout periods. Diet S compared with diet P resulted in significant reduction in plasma cholesterol (22%) LDL cholesterol (26%), apolipoprotein B (18%), HDL cholesterol (12%), apolipoprotein A-I (13%), and a 13% lower factor VII coagulant activity (P = 0.001). Similar differences were observed between diets S and ML. In conclusion, intake of shea butter high in stearic acid favorably affects blood lipids and factor VII coagulant activity in young men, compared with fats high in saturated fatty acids with 12-16 carbons.

  1. Interpretation of coagulation test results using a web-based reporting system.

    PubMed

    Quesada, Andres E; Jabcuga, Christine E; Nguyen, Alex; Wahed, Amer; Nedelcu, Elena; Nguyen, Andy N D

    2014-01-01

    Web-based synoptic reporting has been successfully integrated into diverse fields of pathology, improving efficiency and reducing typographic errors. Coagulation is a challenging field for practicing pathologists and pathologists-in-training alike. To develop a Web-based program that can expedite the generation of a individualized interpretive report for a variety of coagulation tests. We developed a Web-based synoptic reporting system composed of 119 coagulation report templates and 38 thromboelastography (TEG) report templates covering a wide range of findings. Our institution implemented this reporting system in July 2011; it is currently used by pathology residents and attending pathologists. Feedback from the users of these reports have been overwhelmingly positive. Surveys note the time saved and reduced errors. Our easily accessible, user-friendly, Web-based synoptic reporting system for coagulation is a valuable asset to our laboratory services. Copyright© by the American Society for Clinical Pathology (ASCP).

  2. Coagulation Management in Jersey Calves: An ex vivo Study.

    PubMed

    Gröning, Sabine; Maas, Judith; van Geul, Svenja; Rossaint, Rolf; Steinseifer, Ulrich; Grottke, Oliver

    2017-01-01

    Jersey calves are frequently used as an experimental animal model for in vivo testing of cardiac assist devices or orthopedic implants. In this ex vivo study, we analyzed the coagulation system of the Jersey calves and the potential of human-based coagulation management to circumvent perioperative bleeding complications during surgery. Experimental Procedure: Blood from 7 Jersey calves was subjected to standard laboratory tests and thromboelastometry analysis. An ex vivo model of dilutional coagulopathy was used to study the effects of fibrinogen or prothrombin complex concentrate supplementation. Fibrinolysis was induced with tissue plasminogen activator to identify potential therapeutic strategies involving tranexamic acid or aprotinin. Furthermore, anticoagulation strategies were evaluated by incubating the blood samples with dabigatran or rivaroxaban. Baseline values for thromboelastometry and standard laboratory parameters, including prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin III, and D-dimers, were established. Fifty percent diluted blood showed a statistically significant impairment of hemostasis. The parameters significantly improved after the administration of fibrinogen or prothrombin complex concentrate. Tranexamic acid and aprotinin ameliorated tissue plasminogen activator-induced fibrinolysis. Both dabigatran and rivaroxaban significantly prolonged the coagulation parameters. In this ex vivo study, coagulation factors, factor concentrate, antifibrinolytic reagents, and anticoagulants regularly used in the clinic positively impacted coagulation parameters in Jersey calf blood. © 2017 S. Karger AG, Basel.

  3. Haemodynamic and anatomic progression of aortic stenosis.

    PubMed

    Nguyen, Virginia; Cimadevilla, Claire; Estellat, Candice; Codogno, Isabelle; Huart, Virginie; Benessiano, Joelle; Duval, Xavier; Pibarot, Philippe; Clavel, Marie Annick; Enriquez-Sarano, Maurice; Vahanian, Alec; Messika-Zeitoun, David

    2015-06-01

    Aortic valve stenosis (AS) is a progressive disease, but the impact of baseline AS haemodynamic or anatomic severity on AS progression remains unclear. In 149 patients (104 mild AS, 36 moderate AS and 9 severe AS) enrolled in 2 ongoing prospective cohorts (COFRASA/GENERAC), we evaluated AS haemodynamic severity at baseline and yearly, thereafter, using echocardiography (mean pressure gradient (MPG)) and AS anatomic severity using CT (degree of aortic valve calcification (AVC)). After a mean follow-up of 2.9±1.0 years, mean MGP increased from 22±11 to 30±16 mm Hg (+3±3 mm Hg/year), and mean AVC from 1108±891 to 1640±1251 AU (arbitrary units) (+188±176 AU/year). Progression of AS was strongly related to baseline haemodynamic severity (+2±3 mm Hg/year in mild AS, +4±3 mm Hg/year in moderate AS and +5±5 mm Hg/year in severe AS (p=0.01)), and baseline haemodynamic severity was an independent predictor of haemodynamic progression (p=0.0003). Annualised haemodynamic and anatomic progression rates were significantly correlated (r=0.55, p<0.0001), but AVC progression rate was also significantly associated with baseline haemodynamic severity (+141±133 AU/year in mild AS, +279±189 AU/year in moderate AS and +361±293 AU/year in severe AS, p<0.0001), and both baseline MPG and baseline AVC were independent determinants of AVC progression (p<0.0001). AS progressed faster with increasing haemodynamic or anatomic severity. Our results suggest that a medical strategy aimed at preventing AVC progression may be useful in all subsets of patients with AS including those with severe AS and support the recommended closer follow-up of patients with AS as AS severity increases. COFRASA (clinicalTrial.gov number NCT 00338676) and GENERAC (clinicalTrial.gov number NCT00647088). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. The use of smoke acid as an alternative coagulating agent for natural rubber sheets' production.

    PubMed

    Ferreira, Vanda S; Rêgo, Ione N C; Pastore, Floriano; Mandai, Mariana M; Mendes, Leonardo S; Santos, Karin A M; Rubim, Joel C; Suarez, Paulo A Z

    2005-03-01

    A comparative study of rubber sheets obtained using formic, acetic, and smoke acid as coagulants is shown for latex obtained from native Amazonian trees and also from commercial cultivated trees. The evaluation of both processes of coagulation was carried out by spectroscopic and physical-chemical analysis, showing no differences in the rubber sheets obtained. This new method of rubber sheet preparation was introduced into Amazonian rainforest rubber tapper communities, which are actually producing in large scale. The physical-mechanical properties were similar among a large sheets made by different rubber tapper communities using this new method.

  5. Effect of acid and pepsin on blood coagulation and platelet aggregation. A possible contributor prolonged gastroduodenal mucosal hemorrhage.

    PubMed

    Green, F W; Kaplan, M M; Curtis, L E; Levine, P H

    1978-01-01

    In a series of in vitro studies, both the soluble (plasmatic) coagulation system and the cellular (platelet-mediated) aspect of coagulation were shown to be extremely sensitive to relatively minor increases in hydrogen ion concentration. All studies became abnormal at pH 6.8. At pH 6.4, assays of the intrinsic and extrinsic coaglution systems, the polymerization of fibrinogen, and assay of the availability of platelet phospholipid (platelet factor 3) were twice prolonged over control values. Platelet aggregation was reduced by more than 50%. At pH 5.4 in vitro, platelet aggregation and plasma coagulation were both virtually abolished. Furthermore, previously formed platelet aggregates disaggregated at a slightly acid pH. Pepsin further enhanced platelet disaggregation. Because gastric acidity is normally two to four orders of magnitude greater than that which abolishes platelet aggregation and plasma clotting in vitro, and pepsin is present in abundance, we call attention to the probable antihemostatic effect of hydrocloric acid and pepsin in the upper gastrointestinal tract. This in vitro study may provide a rationale for meticulous regulation of intragastric pH in an effort to control upper gastrointestinal hemorrhage.

  6. A new inorganic-organic composite coagulant, consisting of polyferric sulphate (PFS) and polyacrylamide (PAA).

    PubMed

    Moussas, P A; Zouboulis, A I

    2009-08-01

    Currently, research is focused on the synthesis of new composite coagulants, which are constituted of both inorganic and organic materials. In this paper, the development of relevant reagents was investigated, by combining the inorganic pre-polymerised iron-based coagulant Polyferric Sulphate (PFS) with an organic, non-ionic polymer (Polyacrylamide, PAA) under different PAA/Fe (mg/l) and OH/Fe molar ratios. Moreover, the new reagents were characterised in terms of typical properties, stability and morphological analysis (XRD, FTIR, SEM). Their coagulation performance, when treating low or high turbid kaolin-humic acid suspensions, was also investigated, whereas the applied coagulation mechanisms were discussed by using the Photometric Dispersion Analysis (PDA) analysis. The results show that the new coagulation reagents present improved properties, including increased effective polymer species concentration, and they exhibit very good stability. The respective tests using PDA confirmed that the predominant coagulation mechanism of PFS-PAA is the bridge formation mechanism. Coagulation experiments in low or high turbid kaolin-humic acid suspensions reveal that the novel composite reagent PFS-PAA exhibits better coagulation performance, when compared with simple PFS, in terms of zeta-potential reduction, turbidity and organic matter removal and residual iron concentration.

  7. Discovery of glycyrrhetinic acid as an orally active, direct inhibitor of blood coagulation factor xa.

    PubMed

    Jiang, Lilong; Wang, Qiong; Shen, Shu; Xiao, Tongshu; Li, Youbin

    2014-03-01

    Factor Xa (FXa) plays an important role in blood coagulation. This study investigated glycyrrhetinic acid, a small molecule derived from Chinese herbs, and whether it has a direct inhibitory effect on FXa to display its anticoagulant activity. Enzyme activities of FXa, plasmin, trypsin and thrombin, inhibition of FXa enzyme kinetics and plasma clotting time by glycyrrhentinic acid were performed in vitro. A rat tail-bleeding model and a rat venous stasis model were also used to evaluate in vivo tail-bleeding time and thrombus formation, respectively. Glycyrrhetinic acid in vitro directly inhibited FXa uncompetitivly with IC50 of 32.6 ± 1.24 μmol/L, and displayed 2-, 14- and 20-fold selectivity for FXa when compared to plasmin, thrombin and trypsin, respectively. The plasma clotting time was increased in a dose-dependent manner. The prothrombin time doubled (PT2), when the concentration of glycyrrhetinic acid reached 2.02 mmol/L. During in vivo experiments intragastric administration of glycyrrhetinic acid caused a dose-dependent reduction in thrombus weight on the rat venous stasis model (all P<0.05). 50 mg/kg glycyrrhetinic acid resulted in 34.8% of venous thrombus weight lost, compared to the control. In addition, 200, 300 and 400 mg/kg doses of glycyrrhetinic acid caused a moderate hemorrhagic effect in the rat tail-bleeding model by prolonging bleeding time 1.1-, 1.5- and 1.9-fold compared to the control, respectively. Glycyrrhetinic acid is a direct inhibitor of FXa that is effective by oral administration, and with further research could be used to treat blood coagulation disorders. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Preparation and Evaluation of Titanium-Based Xerogel as a Promising Coagulant for Water/Wastewater Treatment.

    PubMed

    Wang, Xiaomeng; Li, Minghui; Song, Xiaojie; Chen, Zhihao; Wu, Bingdang; Zhang, Shujuan

    2016-09-06

    The nontoxicity of titanium (Ti) and the potential to produce valuable photocatalysts from the final coagulated sludge constitute the main advantages of Ti-based coagulants over conventional ones. However, the low effluent pH and the too-fast hydrolysis limit the wide application of Ti-salt coagulants. Prehydrolysis, to some extent, is helpful to improve the coagulation performance of Ti-salt coagulants. However, the prehydrolyzed polytitanium chloride (PTC) still suffers from narrow applicable dose/pH range. A novel and efficient Ti-based coagulant, denoted as titanium xerogel coagulant (TXC), was successfully prepared by the sol-gel method with TiCl4 as the precursor and acetylacetone as a modifying agent. Compared with TiCl4, a PTC, and a commercial polyferric sulfate, the resulting TXC possessed a larger floc size, better settling property, and wider applicable coagulant dose/pH range. Moreover, the effluent pH after TXC coagulation was not significantly reduced, avoiding the corrosion problem sometimes caused by the low effluent pH. TXC exhibited good coagulation performance for several real wastewaters, especially for the wastewaters of low turbidity. These results demonstrate that gelation was a more effective strategy than prehydrolysis to overcome the inherent weaknesses of Ti salts as a type of promising coagulants.

  9. Haemodynamic coherence - The relevance of fluid therapy.

    PubMed

    Arnemann, Philip; Seidel, Laura; Ertmer, Christian

    2016-12-01

    The ultimate goal of fluid therapy is to improve the oxygenation of cells by improving the cardiac output, thus improving microcirculation by optimizing macrocirculation. This haemodynamic coherence is often altered in patients with haemorrhagic shock and sepsis. The loss of haemodynamic coherence is associated with adverse outcomes. It may be influenced by the mechanisms of the underlying disease and properties of different fluids used for resuscitation in these critically ill patients. Monitoring microcirculation and haemodynamic coherence may be an additional tool to predict the response to fluid administration. In addition, microcirculatory analysis may support the clinician in his decision to not administer fluids when microcirculatory blood flow is preserved. In future, the indication, guidance and termination of fluid therapy may be assessed by bedside microvascular analysis in combination with standard haemodynamic monitoring. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Effects of an acidic environment on coagulation dynamics.

    PubMed

    Gissel, M; Brummel-Ziedins, K E; Butenas, S; Pusateri, A E; Mann, K G; Orfeo, T

    2016-10-01

    Essentials Acidosis, an outcome of traumatic injury, has been linked to impaired procoagulant efficiency. In vitro model systems were used to assess coagulation dynamics at pH 7.4 and 7.0. Clot formation dynamics are slightly enhanced at pH 7.0 in blood ex vivo. Acidosis induced decreases in antithrombin efficacy offset impairments in procoagulant activity. Background Disruption of hydrogen ion homeostasis is a consequence of traumatic injury often associated with clinical coagulopathy. Mechanisms by which acidification of the blood leads to aberrant coagulation require further elucidation. Objective To examine the effects of acidified conditions on coagulation dynamics using in vitro models of increasing complexity. Methods Coagulation dynamics were assessed at pH 7.4 and 7.0 as follows: (i) tissue factor (TF)-initiated coagulation proteome mixtures (±factor [F]XI, ±fibrinogen/FXIII), with reaction progress monitored as thrombin generation or fibrin formation; (ii) enzyme/inhibitor reactions; and (iii) TF-dependent or independent clot dynamics in contact pathway-inhibited blood via viscoelastometry. Results Rate constants for antithrombin inhibition of FXa and thrombin were reduced by ~ 25-30% at pH 7.0. At pH 7.0 (+FXI), TF-initiated thrombin generation showed a 20% increase in maximum thrombin levels and diminished thrombin clearance rates. Viscoelastic analyses showed a 25% increase in clot time and a 25% reduction in maximum clot firmness (MCF). A similar MCF reduction was observed at pH 7.0 when fibrinogen/FXIII were reacted with thrombin. In contrast, in contact pathway-inhibited blood (n = 6) at pH 7.0, MCF values were elevated 6% (95% confidence interval [CI]: 1%-11%) in TF-initiated blood and 15% (95% CI: 1%- 29%) in the absence of TF. Clot times at pH 7.0 decreased 32% (95% CI: 15%-49%) in TF-initiated blood and 51% (95% CI: 35%-68%) in the absence of TF. Conclusions Despite reported decreased procoagulant catalysis at pH 7.0, clot formation dynamics

  11. Relationship between haemodynamic impairment and collateral blood flow in carotid artery disease.

    PubMed

    Hartkamp, Nolan S; Petersen, Esben T; Chappell, Michael A; Okell, Thomas W; Uyttenboogaart, Maarten; Zeebregts, Clark J; Bokkers, Reinoud Ph

    2017-01-01

    Collateral blood flow plays a pivotal role in steno-occlusive internal carotid artery (ICA) disease to prevent irreversible ischaemic damage. Our aim was to investigate the effect of carotid artery disease upon cerebral perfusion and cerebrovascular reactivity and whether haemodynamic impairment is influenced at brain tissue level by the existence of primary and/or secondary collateral. Eighty-eight patients with steno-occlusive ICA disease and 29 healthy controls underwent MR examination. The presence of collaterals was determined with time-of-flight, two-dimensional phase contrast MRA and territorial arterial spin labeling (ASL) imaging. Cerebral blood flow and cerebrovascular reactivity were assessed with ASL before and after acetazolamide. Cerebral haemodynamics were normal in asymptomatic ICA stenosis patients, as opposed to patients with ICA occlusion, in whom the haemodynamics in both hemispheres were compromised. Haemodynamic impairment in the affected brain region was always present in symptomatic patients. The degree of collateral blood flow was inversely correlated with haemodynamic impairment. Recruitment of secondary collaterals only occurred in symptomatic ICA occlusion patients. In conclusion, both CBF and cerebrovascular reactivity were found to be reduced in symptomatic patients with steno-occlusive ICA disease. The presence of collateral flow is associated with further haemodynamic impairment. Recruitment of secondary collaterals is associated with severe haemodynamic impairment.

  12. Postprandial changes in platelet function and coagulation factors after high-fat meals with different fatty acid compositions.

    PubMed

    Freese, R; Mutanen, M

    1995-09-01

    To compare the postprandial effects of three oils differing in their fatty acid composition on platelet aggregation and coagulation. The oils studied were low-erucic acid rapeseed oil (RO, oleic acid 54% of fatty acids), sunflower oil (SO, linoleic acid 64% of fatty acids) and butter oil (BO, saturated fatty acids 62% of fatty acids). The postprandial effects of three fat-loads were followed for 5 h. Division of Nutrition, University of Helsinki. Twelve healthy female subjects (aged 23-38 years) were recruited among university students and employees. Postprandial lipaemia was induced by high-fat meals containing fat (RO, SO or BO) 1 g/kg of body weight, skim-milk powder, sugar, strawberries, and water. Each subject ingested each meal in three separate mornings after an overnight fast. The order of the meals was randomised. Blood samples were taken before and 1, 2.5, and 5 h after the test meal. All three test meals similarly affected platelet aggregation in platelet-rich plasma. Aggregation induced by collagen (0.6, 1 and 2.5 micrograms/ml) decreased during the 5-h period after the meals (P = 0.000). ADP-induced aggregation did not change during the follow-up period after any meal (P = 0.105-0.483). All fat loads increased factor VII coagulant activity (F VII:C) (P = 0.000), but in plasma fibrinogen concentration (P = 0.155) or antithrombin III activity (P = 0.278) no postprandial changes were found. These results show that high-fat meals have acute effects on platelet function and F VII:C in healthy women and that these effects are not mediated through the fatty acid composition of the meals.

  13. Blood coagulation screening using a paper-based microfluidic lateral flow device.

    PubMed

    Li, H; Han, D; Pauletti, G M; Steckl, A J

    2014-10-21

    A simple approach to the evaluation of blood coagulation using a microfluidic paper-based lateral flow assay (LFA) device for point-of-care (POC) and self-monitoring screening is reported. The device utilizes whole blood, without the need for prior separation of plasma from red blood cells (RBC). Experiments were performed using animal (rabbit) blood treated with trisodium citrate to prevent coagulation. CaCl2 solutions of varying concentrations are added to citrated blood, producing Ca(2+) ions to re-establish the coagulation cascade and mimic different blood coagulation abilities in vitro. Blood samples are dispensed into a paper-based LFA device consisting of sample pad, analytical membrane and wicking pad. The porous nature of the cellulose membrane separates the aqueous plasma component from the large blood cells. Since the viscosity of blood changes with its coagulation ability, the distance RBCs travel in the membrane in a given time can be related to the blood clotting time. The distance of the RBC front is found to decrease linearly with increasing CaCl2 concentration, with a travel rate decreasing from 3.25 mm min(-1) for no added CaCl2 to 2.2 mm min(-1) for 500 mM solution. Compared to conventional plasma clotting analyzers, the LFA device is much simpler and it provides a significantly larger linear range of measurement. Using the red colour of RBCs as a visible marker, this approach can be utilized to produce a simple and clear indicator of whether the blood condition is within the appropriate range for the patient's condition.

  14. Coagulation removal of humic acid-stabilized carbon nanotubes from water by PACl: influences of hydraulic condition and water chemistry.

    PubMed

    Ma, Si; Liu, Changli; Yang, Kun; Lin, Daohui

    2012-11-15

    Discharged carbon nanotubes (CNTs) can adsorb the widely-distributed humic acid (HA) in aquatic environments and thus be stabilized. HA-stabilized CNTs can find their way into and challenge the potable water treatment system. This study investigated the efficiency of coagulation and sedimentation techniques in the removal of the HA-stabilized multi-walled carbon nanotubes (MWCNTs) using polyaluminum chloride (PACl) as a coagulant, with a focus on the effects of hydraulic conditions and water chemistry. Stirring speeds in the mixing and reacting stages were gradually changed to examine the effect of the hydraulic conditions on the removal rate. The stirring speed in the reacting stage affected floc formation and thereby had a greater impact on the removal rate than the stirring speed in the mixing stage. Water chemistry factors such as pH and ionic strength had a significant effect on the stability of MWCNT suspension and the removal efficiency. Low pH (4-7) was favorable for saving the coagulant and maintaining high removal efficiency. High ionic strength facilitated the destabilization of the HA-stabilized MWCNTs and thereby lowered the required PACl dosage for the coagulation. However, excessively high ionic strength (higher than the critical coagulation concentration) decreased the maximum removal rate, probably by inhibiting ionic activity of PACl hydrolyzate in water. These results are expected to shed light on the potential improvement of coagulation removal of aqueous stabilized MWCNTs in water treatment systems. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Coagulation behavior of humic acid in aqueous solutions containing Cs+, Sr2+ and Eu3+: DLS, EEM and MD simulations.

    PubMed

    Tan, Liqiang; Tan, Xiaoli; Mei, Huiyang; Ai, Yuejie; Sun, Lu; Zhao, Guixia; Hayat, Tasawar; Alsaedi, Ahmed; Chen, Changlun; Wang, Xiangke

    2018-05-01

    The coagulation behaviors of humic acid (HA) with Cs + (10-500 mM), Sr 2+ (0.8-10.0 mM) and Eu 3+ (0.01-1.0 mM) at different pH values (2.8, 7.1 and 10.0) were acquired through a dynamic light scattering (DLS) technique combined with spectroscopic analysis and molecular dynamic (MD) simulations. The coagulation rate and the average hydrodynamic diameter () increased significantly as the concentration of nuclides increased. could be scaled to time t as ∝ t a at higher Sr 2+ concentrations, which shows that HA coagulation is consistent with the diffusion-limited colloid aggregation (DLCA) model. Trivalent Eu 3+ induced HA coagulation at a much lower concentration than bivalent Sr 2+ and monovalent Cs + . The coagulation value ratio of Sr 2+ and Eu 3+ to Cs + is almost proportional to Z -6 , indicating that the HA coagulation process is generally consistent with the Schulze-Hardy rule. Spectroscopic analysis indicated that the complexation between nuclides and carboxylic/phenolic groups of HA molecules played important roles in the coagulation of HA. MD modelling suggested that Sr 2+ and Eu 3+ ions increased the coagulation process through the formation of intra- or inter-molecular bridges between negatively charged HA molecules, whereas for Cs + , no inter-molecular bridges were formed. This work offers new insight into the interactions between HA and radionuclides and provides a prediction for the roles of HA in the transportation and elimination of radionuclides in severely polluted environments. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. ANFIS-based modelling for coagulant dosage in drinking water treatment plant: a case study.

    PubMed

    Heddam, Salim; Bermad, Abdelmalek; Dechemi, Noureddine

    2012-04-01

    Coagulation is the most important stage in drinking water treatment processes for the maintenance of acceptable treated water quality and economic plant operation, which involves many complex physical and chemical phenomena. Moreover, coagulant dosing rate is non-linearly correlated to raw water characteristics such as turbidity, conductivity, pH, temperature, etc. As such, coagulation reaction is hard or even impossible to control satisfactorily by conventional methods. Traditionally, jar tests are used to determine the optimum coagulant dosage. However, this is expensive and time-consuming and does not enable responses to changes in raw water quality in real time. Modelling can be used to overcome these limitations. In this study, an Adaptive Neuro-Fuzzy Inference System (ANFIS) was used for modelling of coagulant dosage in drinking water treatment plant of Boudouaou, Algeria. Six on-line variables of raw water quality including turbidity, conductivity, temperature, dissolved oxygen, ultraviolet absorbance, and the pH of water, and alum dosage were used to build the coagulant dosage model. Two ANFIS-based Neuro-fuzzy systems are presented. The two Neuro-fuzzy systems are: (1) grid partition-based fuzzy inference system (FIS), named ANFIS-GRID, and (2) subtractive clustering based (FIS), named ANFIS-SUB. The low root mean square error and high correlation coefficient values were obtained with ANFIS-SUB method of a first-order Sugeno type inference. This study demonstrates that ANFIS-SUB outperforms ANFIS-GRID due to its simplicity in parameter selection and its fitness in the target problem.

  17. Implementation of a microcontroller-based semi-automatic coagulator.

    PubMed

    Chan, K; Kirumira, A; Elkateeb, A

    2001-01-01

    The coagulator is an instrument used in hospitals to detect clot formation as a function of time. Generally, these coagulators are very expensive and therefore not affordable by a doctors' office and small clinics. The objective of this project is to design and implement a low cost semi-automatic coagulator (SAC) prototype. The SAC is capable of assaying up to 12 samples and can perform the following tests: prothrombin time (PT), activated partial thromboplastin time (APTT), and PT/APTT combination. The prototype has been tested successfully.

  18. Performance and characterization of a new tannin-based coagulant

    NASA Astrophysics Data System (ADS)

    Beltrán-Heredia, J.; Sánchez-Martín, J.; Gómez-Muñoz, C.

    2012-09-01

    Diethanolamine and formaldehyde were employed to cationize tannins from black wattle. This novel coagulant called CDF was functionally characterized in removing sodium dodecylbenzene sulfonate (anionic surfactant) and Palatine Fast Black WAN (azoic dye). Refined tannin-derived commercial coagulants exhibited similar efficiency, while CDF presented higher coagulant ability than alum, a usual coagulant agent. Low doses of CDF (ca. 100 mg L-1) were able to remove more than 70 % of surfactant and more than 85 % of dye (initial pollutant concentration of ca. 100 mg L-1) and it presented no temperature affection and worked at a relatively wide pH range. Surfactant and dye removal responded to the classical coagulant-and-adsorption models, such as Frumkin-Fowler-Guggenheim or Gu and Zhu in the case of surfactant, and Langmuir and Freundlich in the case of dye.

  19. Haemodynamic changes in trauma.

    PubMed

    Kirkman, E; Watts, S

    2014-08-01

    Trauma is the leading cause of death during the first four decades of life in the developed countries. Its haemodynamic response underpins the patient's initial ability to survive, and the response to treatment and subsequent morbidity and resolution. Trauma causes a number of insults including haemorrhage, tissue injury (nociception) and, predominantly, in military casualties, blast from explosions. This article discusses aspects of the haemodynamic responses to these insults and subsequent treatment. 'Simple' haemorrhage (blood loss without significant volume of tissue damage) causes a biphasic response: mean arterial blood pressure (MBP) is initially maintained by the baroreflex (tachycardia and increased vascular resistance, Phase 1), followed by a sudden decrease in MAP initiated by a second reflex (decrease in vascular resistance and bradycardia, Phase 2). Phase 2 may be protective. The response to tissue injury attenuates Phase 2 and may cause a deleterious haemodynamic redistribution that compromises blood flow to some vital organs. In contrast, thoracic blast exposure augments Phase 2 of the response to haemorrhage. However, hypoxaemia from lung injury limits the effectiveness of hypotensive resuscitation by augmenting the attendant shock state. An alternative strategy ('hybrid resuscitation') whereby tissue perfusion is increased after the first hour of hypotensive resuscitation by adopting a revised normotensive target may ameliorate these problems. Finally, morphine also attenuates Phase 2 of the response to haemorrhage in some, but not all, species and this is associated with poor outcome. The impact on human patients is currently unknown and is the subject of a current physiological investigation. © Crown copyright 2014. Published with the permission of the Defence Science and Technology Laboratory on behalf of the Controller of HMSO. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Chemical coagulation-based processes for trace organic contaminant removal: current state and future potential.

    PubMed

    Alexander, Jonathan T; Hai, Faisal I; Al-Aboud, Turki M

    2012-11-30

    Trace organic contaminants have become an increasing cause of concern for governments and water authorities as they attempt to respond to the potential challenges posed by climate change by implementing sustainable water cycle management practices. The augmentation of potable water supplies through indirect potable water reuse is one such method currently being employed. Given the uncertainty surrounding the potential human health impacts of prolonged ingestion of trace organic contaminants, it is vital that effective and sustainable treatment methods are utilized. The purpose of this article is to provide a comprehensive literature review of the performance of the chemical coagulation process in removing trace organic contaminants from water. This study evaluated the removal data collated from recent research relating to various trace organic contaminants during the coagulation process. It was observed that there is limited research data relating to the removal of trace organic contaminants using coagulation. The findings of this study suggest that there is a gap in the current research investigating the potential of new types of coagulants and exploring coagulation-based hybrid processes to remove trace organic contaminants from water. The data analysed in this study regarding removal efficiency suggests that, even for the significantly hydrophobic compounds, hydrophobicity is not the sole factor governing removal of trace organic contaminants by coagulation. This has important implications in that the usual practice of screening coagulants based on turbidity (suspended solid) removal proves inadequate in the case of trace organic contaminant removal. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Oxidation and coagulation of humic substances by potassium ferrate.

    PubMed

    Graham, N J D; Khoi, T T; Jiang, J-Q

    2010-01-01

    Ferrate (FeO₄²⁻) is believed to have a dual role in water treatment, both as oxidant and coagulant. Few studies have considered the coagulation effect in detail, mainly because of the difficulty of separating the oxidation and coagulation effects. This paper summarises some preliminary results from laboratory-based experiments that are investigating the coagulation reaction dynamically via a PDA instrument, between ferrate and humic acid (HA) at different doses and pH values, and comparing the observations with the use of ferric chloride. The PDA output gives a comparative measure of the rate of floc growth and the magnitude of floc formation. The results of the tests show some significant differences in the pattern of behaviour between ferrate and ferric chloride. At pH 5 the chemical dose range (as Fe) corresponding to HA coagulation was much broader for ferrate than ferric chloride, and the optimal Fe dose was greater. Ferrate oxidation appears to increase the hydrophilic and electronegative nature of the HA leading to an extended region of charge neutralisation. A consequence of the ferrate oxidation is that the extent of HA removal was slightly lower ( approximately 5%) than with ferric chloride. At pH 7, in the sweep flocculation domain, ferrate achieved much greater floc formation than ferric chloride, but a substantially lower degree of HA removal.

  2. An updated concept of coagulation with clinical implications.

    PubMed

    Romney, Gregory; Glick, Michael

    2009-05-01

    Over the past century, a series of models have been put forth to explain the coagulation mechanism. The coagulation cascade/waterfall model has gained the most widespread acceptance. This model, however, has problems when it is used in different clinical scenarios. A more recently proposed cell-based model better describes the coagulation process in vivo and provides oral health care professionals (OHCPs) with a better understanding of the clinical implications of providing dental care to patients with potentially increased bleeding tendencies. The authors conducted a literature search using the PubMed database. They searched for key words including "coagulation," "hemostasis," "bleeding," "coagulation factors," "models," "prothrombin time," "activated partial thromboplastin time," "international normalized ratio," "anticoagulation therapy" and "hemophilia" separately and in combination. The coagulation cascade/waterfall model is insufficient to explain coagulation in vivo, predict a patient's bleeding tendency, or correlate clinical outcomes with specific laboratory screening tests such as prothrombin time, activated partial thromboplastin time and international normalized ratio. However, the cell-based model of coagulation that reflects the in vivo process of coagulation provides insight into the clinical ramifications of treating dental patients with specific coagulation factor deficiencies. Understanding the in vivo coagulation process will help OHCPs better predict a patient's bleeding tendency. In addition, applying the theoretical concept of the cell-based model of coagulation to commonly used laboratory screening tests for coagulation and bleeding will result in safer and more appropriate dental care.

  3. Effects of dairy factory, milk casein content and titratable acidity on coagulation properties in Trentingrana dairy industry.

    PubMed

    Penasa, Mauro; Toffanin, Valentina; Cologna, Nicola; Cassandro, Martino; De Marchi, Massimo

    2016-05-01

    The objective of the present study was to investigate the effect of environmental factors, milk casein content and titratable acidity on milk coagulation properties (MCP) of samples routinely collected in the Trento province (northeast Italy) under field conditions. Rennet coagulation time (RCT, min), curd-firming time (k20, min) and curd firmness (a30, mm) were determined by Formagraph on 14 971 samples from 635 herds associated to 17 dairy factories. Besides MCP, fat, protein, and casein percentages, titratable acidity (TA), and somatic cell and bacterial counts were available. A standardised index of milk aptitude to coagulate (IAC) was derived using information of RCT and a30. An analysis of variance was conducted on MCP and IAC using a fixed effects linear model. Approximately 3% of milk samples did not form a curd within the testing time (30 min) and k20 was missing for 26% of milks. The percentage of samples without information on k20 largely differed among dairy factories (1·7-20·9%). Significant differences were estimated between the best and the worst dairy factory for RCT (-2 min), k20 (-1·2 min), a30 (+3·4 mm) and IAC (+2·6 points). Milk casein content and TA were important factors in explaining the variation of MCP and IAC, supporting the central role of these two traits on technological properties. The Trento province is heterogeneous in terms of dairy systems and this could explain the differences among dairy factories.

  4. Assessing paedophilia based on the haemodynamic brain response to face images.

    PubMed

    Ponseti, Jorge; Granert, Oliver; Van Eimeren, Thilo; Jansen, Olav; Wolff, Stephan; Beier, Klaus; Deuschl, Günther; Huchzermeier, Christian; Stirn, Aglaja; Bosinski, Hartmut; Roman Siebner, Hartwig

    2016-01-01

    Objective assessment of sexual preferences may be of relevance in the treatment and prognosis of child sexual offenders. Previous research has indicated that this can be achieved by pattern classification of brain responses to sexual child and adult images. Our recent research showed that human face processing is tuned to sexual age preferences. This observation prompted us to test whether paedophilia can be inferred based on the haemodynamic brain responses to adult and child faces. Twenty-four men sexually attracted to prepubescent boys or girls (paedophiles) and 32 men sexually attracted to men or women (teleiophiles) were exposed to images of child and adult, male and female faces during a functional magnetic resonance imaging (fMRI) session. A cross-validated, automatic pattern classification algorithm of brain responses to facial stimuli yielded four misclassified participants (three false positives), corresponding to a specificity of 91% and a sensitivity of 95%. These results indicate that the functional response to facial stimuli can be reliably used for fMRI-based classification of paedophilia, bypassing the problem of showing child sexual stimuli to paedophiles.

  5. Coagulation monitoring based on blood elastic measurement using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Xu, Xiangqun; Zhu, Jiang; Chen, Zhongping

    2017-02-01

    Blood coagulation monitoring is important to diagnose hematological diseases and cardiovascular diseases and to predict the risk of bleeding and excessive clotting. In this study, we developed a system to dynamically monitor blood coagulation and quantitatively determine the coagulation function by blood elastic measurement. When blood forms a clot from a liquid, ultrasonic force induces a shear wave, which is detected by optical coherence tomography (OCT). The coagulation of porcine whole blood recalcified by calcium chloride is assessed using the metrics of reaction time, clot formation kinetics and maximum shear modulus. The OCE system can noninvasively monitor the blood coagulation and quantitatively determine the coagulation function.

  6. Coagulant from Leucaena leucocephala for Chromium Removal

    NASA Astrophysics Data System (ADS)

    Razak, N. H. Abd; Khairuddin, N.; Ismail, K. N.; Musa, M.

    2018-05-01

    This research investigated the effectiveness of leucaena leucocephala as a natural coagulant for chromium removal. Leucaena leucocephala is a permanent non-climbing shrub tree which is wild and abundant in Malaysia and commonly known as petai belalang. Coagulation experiment using jar test were performed where the effect of coagulant dosage and pH were examined. The parameters investigated were suspended solid (SS), chemical oxygen demand (COD), biological oxygen demand (BOD), turbidity and chromium content. The optimum of leucaena leucocephala coagulant dosage for removal of suspended solid, turbidity, COD, BOD and Chromium is at range 400-600 mg/L which yielded 45, 31.4, 38.5, 27.5 and 4.05% removal respectively. While the optimum pH is at pH 2-4 (acidic) which give 33.3, 26.8, 33.75, 31.4 and 14.06% removal of suspended solid, COD, BOD, turbidity and chromium content respectively. It is concluded that the leucaena leucocephala showed tremendous potential for chromium removal.

  7. Coagulation behavior and floc characteristics of a novel composite poly-ferric aluminum chloride-polydimethyl diallylammonium chloride coagulant with different OH/(Fe3+ + Al3+) molar ratios.

    PubMed

    Sun, Cuizhen; Qiu, Jinwei; Zhang, Zhibin; Marhaba, Taha F; Zhang, Yanhao

    2016-10-01

    In this paper, flocculating performance and mechanisms of a new composite coagulant, poly-ferric aluminum chloride-polydimethyl diallylammonium chloride (PFAC-PD) with different OH - /(Fe 3+ + Al 3+ ) molar ratios, were investigated for humic acid (HA)-kaolin synthetic wastewater treatment. The impact of OH - /(Fe 3+ + Al 3+ ) molar ratios on the removal efficiencies of turbidity and dissolved organic carbon, specific UV absorbance, coagulation mechanisms and dynamics was explored during the coagulation process using composite coagulants. The coagulation experimental results revealed that the composite coagulants with lower OH - /(Fe 3+ + Al 3+ ) molar ratio exhibited better coagulation efficiency. When OH - /(Fe 3+ + Al 3+ ) molar ratio of the composite coagulant was 1.5, adsorption-bridging played a dominant role in coagulating HA-kaolin synthetic wastewater. The floc growth rate and floc size, increased with increasing OH - /(Fe 3+ + Al 3+ ) molar ratio and the highest peak height of the size distribution was obtained by PFAC-PD with OH - /(Fe 3+ + Al 3+ ) = 1.5. Also, the composite coagulants with higher OH - /(Fe 3+ + Al 3+ ) molar ratio formed more compact flocs, as reflected by the higher fractal dimension value. The flocs coagulated by PFAC-PD with basicity value of 1.0 gave strong strength and good recoverability.

  8. Coagulant recovery and reuse for drinking water treatment.

    PubMed

    Keeley, James; Jarvis, Peter; Smith, Andrea D; Judd, Simon J

    2016-01-01

    Coagulant recovery and reuse from waterworks sludge has the potential to significantly reduce waste disposal and chemicals usage for water treatment. Drinking water regulations demand purification of recovered coagulant before they can be safely reused, due to the risk of disinfection by-product precursors being recovered from waterworks sludge alongside coagulant metals. While several full-scale separation technologies have proven effective for coagulant purification, none have matched virgin coagulant treatment performance. This study examines the individual and successive separation performance of several novel and existing ferric coagulant recovery purification technologies to attain virgin coagulant purity levels. The new suggested approach of alkali extraction of dissolved organic compounds (DOC) from waterworks sludge prior to acidic solubilisation of ferric coagulants provided the same 14:1 selectivity ratio (874 mg/L Fe vs. 61 mg/L DOC) to the more established size separation using ultrafiltration (1285 mg/L Fe vs. 91 mg/L DOC). Cation exchange Donnan membranes were also examined: while highly selective (2555 mg/L Fe vs. 29 mg/L DOC, 88:1 selectivity), the low pH of the recovered ferric solution impaired subsequent treatment performance. The application of powdered activated carbon (PAC) to ultrafiltration or alkali pre-treated sludge, dosed at 80 mg/mg DOC, reduced recovered ferric DOC contamination to <1 mg/L but in practice, this option would incur significant costs. The treatment performance of the purified recovered coagulants was compared to that of virgin reagent with reference to key water quality parameters. Several PAC-polished recovered coagulants provided the same or improved DOC and turbidity removal as virgin coagulant, as well as demonstrating the potential to reduce disinfection byproducts and regulated metals to levels comparable to that attained from virgin material. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Ex Vivo Liver Experiment of Hydrochloric Acid-Infused and Saline-Infused Monopolar Radiofrequency Ablation: Better Outcomes in Temperature, Energy, and Coagulation.

    PubMed

    Jiang, Xiong-ying; Gu, Yang-kui; Huang, Jin-hua; Gao, Fei; Zou, Ru-hai; Zhang, Tian-qi

    2016-04-01

    To compare temperature, energy, and coagulation between hydrochloric acid-infused radiofrequency ablation (HAIRFA) and normal saline-infused radiofrequency ablation (NSIRFA) in ex vivo porcine liver model. 30 fresh porcine livers were excised in 60 lesions, 30 with HAIRFA and the other 30 with NSIRFA. Both modalities used monopolar perfusion electrode connected to a RF generator set at 103 °C and 30 W. In each group, ablation time was set at 10, 20, or 30 min (10 lesions from each group at each time). We compared tissue temperatures (at 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 cm away from the electrode tip), average power, deposited energy, deposited energy per coagulation volume (DEV), coagulation diameters, coagulative volume, and spherical ratio between the two groups. Temperature-time curves showed that HAIRFA provided progressively greater heating than that of NSIRFA. At 30 min, mean average power, deposited energy, coagulation volumes (113.67 vs. 12.28 cm(3)) and diameters, and increasing in tissue temperature were much greater with HAIRFA (P < 0.001 for all), except DEV was lower (456 vs. 1396 J/cm(3), P < 0.001). The spherical ratio was closer to 1 with HAIRFA (1.23 vs. 1.46). Coagulation diameters, volume, and average power of HAIRFA increased significantly with longer ablation times. While with NSIRFA, these characteristics were stable till later 20 min, except the power decreased with longer ablation times. HAIRFA creates much larger and more spherical lesions by increasing overall energy deposition, modulating thermal conductivity, and transferring heat during ablation.

  10. Prevalence of nucleic acid sequences specific for human parvoviruses, hepatitis A and hepatitis E viruses in coagulation factor concentrates.

    PubMed

    Modrow, S; Wenzel, J J; Schimanski, S; Schwarzbeck, J; Rothe, U; Oldenburg, J; Jilg, W; Eis-Hübinger, A M

    2011-05-01

    Due to their high resistance to inactivation procedures, nonenveloped viruses such as parvovirus B19, human bocavirus (HBoV), human parvovirus 4 (PARV4), hepatitis A (HAV) and hepatitis E virus (HEV) pose a particular threat to blood products. Virus transmission to patients treated with blood products presents an additional burden to disease. We determined the frequency and the amount of nucleic acid specific for nonenveloped viruses in recently manufactured preparations of commercial coagulation factor concentrates. At least three different batches of each of 13 different plasma-derived and recombinant coagulation factor products were tested for the presence and the amount of nucleic acid for parvovirus B19, HBoV, human parvovirus 4, hepatitis A virus and HEV by using quantitative polymerase chain reaction. Whereas none of the recombinant products tested positive for any of these viruses, parvovirus B19 DNA with amounts ranging between 2×10(1) and 1.3×10(3) genome equivalents/ml was detected in five plasma-derived products. In addition to parvovirus B19 genotype 1, genotypes 2 and 3 were observed in two batches of a factor VIII/von-Willebrand factor product. In two products (one factor VIII concentrate and one activated prothrombin complex concentrate), a combination of both genotypes 1 and 2 of parvovirus B19 was detected. The data show that nucleic acids from several relevant nonenveloped viruses are not found at detectable levels in coagulation factor concentrates. In some cases, parvovirus B19 DNA was detectable at low levels. Testing of the plasma pools for the full range of parvovirus genotypes is advocated for ensuring product safety. © 2010 The Author(s). Vox Sanguinis © 2010 International Society of Blood Transfusion.

  11. Influence of micellar calcium and phosphorus on rennet coagulation properties of cows milk.

    PubMed

    Malacarne, Massimo; Franceschi, Piero; Formaggioni, Paolo; Sandri, Sandro; Mariani, Primo; Summer, Andrea

    2014-05-01

    The main requirement for milk processed in most cheese typologies is its rennet coagulation ability. Despite the increasing number of studies, the causes for abnormal coagulation of milk are not fully understood. The aim of this study was to ascertain relationships between milk characteristics and its rennet coagulation ability, focusing on the influence of calcium (Ca) and phosphorus (P). Ca and P are essential constituents of the micelles. Micellar P can be present as part of colloidal calcium phosphate (inorganic-P) or covalently bound to caseins as phosphate groups (casein-P). Eighty one herd milk samples (SCC<400 000 cell/ml) were classified as Optimal (8), Suboptimal (39) Poor (29) and Non-coagulating milk (5), according to their rennet coagulation parameters as assessed by lactodynamographic test. Samples were analysed for their chemical composition (basic composition, protein fractions, minerals and salt equilibria), physicochemical parameters (pH and titratable acidity) and rheological properties. Optimal milk was characterised by the highest contents of major constituents, protein fractions and minerals, lowest content of chloride and highest values of titratable acidity. Non-coagulating milk was characterised by the highest values of pH and the lowest of titratable acidity. At micellar level, Optimal milk showed the highest values of colloidal Ca, casein-P and colloidal Mg (g/100 g casein), while Non-coagulating milk showed the lowest values. Interestingly, there was no statistical difference regarding the content of colloidal inorganic-P (g/100 g casein) between Optimal and Non-coagulating milks. Overall, high mineralisation of the micelle (expressed as g inorganic-P/100 g casein) positively affect its rennetability. However, excessive mineralisation could lead to a reduction of the phosphate groups (g casein-P/100 g casein) available for curd formation.

  12. Characteristics of BPA removal from water by PACl-Al13 in coagulation process.

    PubMed

    Xiaoying, Ma; Guangming, Zeng; Chang, Zhang; Zisong, Wang; Jian, Yu; Jianbing, Li; Guohe, Huang; Hongliang, Liu

    2009-09-15

    This paper discussed the coagulation characteristics of BPA with polyaluminum chloride (PACl-Al(13)) as coagulant, examined the impact of coagulation pH, PACl-Al(13) dosage, TOC (total organic carbon) and turbidity on BPA removal, and analyzed the possible dominant mechanisms in water coagulation process. Formation and performance of flocs during coagulation processes were monitored using photometric dispersion analyzer (PDA). When the concentration of humic acid matters and turbidity was low in the solution, the experimental results showed that the removal of BPA experienced increase and subsequently decrease with the PACl-Al(13) dosage increasing. The optimal PACl-Al(13) dosage was found at BPA/PACl-Al(13)=1:2.6(M/M) under our experiment conditions. Results show that the maximum BPA removal efficiency occurred at pH 9.0 due to the adsorption by Al(13) aggregates onto BPA rather than charge neutralization mechanism by polynuclear aluminous salts in the solution. The humic acid matters and kaolin in the solution have significant effect on BPA removal with PACl-Al(13) in the coagulation. The BPA removal will be weakened at high humic matters. The removal rate of BPA increased and subsequently decreased with the turbidity increasing.

  13. In situ coagulation versus pre-coagulation for gravity-driven membrane bioreactor during decentralized sewage treatment: Permeability stabilization, fouling layer formation and biological activity.

    PubMed

    Ding, An; Wang, Jinlong; Lin, Dachao; Tang, Xiaobin; Cheng, Xiaoxiang; Li, Guibai; Ren, Nanqi; Liang, Heng

    2017-12-01

    Gravity-driven membrane filtration systems are promising for decentralized sewage treatment due to their low energy consumption and low maintenance. However, the low stable permeability/flux is currently limiting their wider application. With the ultimate goal of increasing permeability, the aim of this study was to evaluate the effect of coagulation (in situ coagulation and pre-coagulation) on the performance of a gravity-driven membrane bioreactor (GDMBR) during treatment of synthetic sewage. Results show that in situ coagulation significantly increased permeability (more than two-fold); however, no stabilization of permeability occurred over the whole operation, when non-coagulated and pre-coagulated reactors were compared. The high permeability observed was attributed to the accumulated aluminium floc in the reactor, which prevented formation of fluorescent microbial metabolites (aromatic and tryptophan proteins, as well as fulvic acids), and further avoided membrane pore blocking. In addition, the surface porosity of the fouling layer was improved (from 11.2% to 32.4% for non-coagulated and in situ coagulated reactors). The unstable permeability was possibly associated with lower biological processes within the fouling layer. These might include lower adenosine triphosphate (ATP) content and lower fluorescent metabolites from the extracellular polymeric substances (EPS) caused by the accumulated Al (compared with the control). On the other hand, pre-coagulation improved the level of stable permeability compared with the control (80 versus 40 L/m 2 h bar), mainly because pre-coagulation decreased the EPS content and also maintained high ATP content of the fouling layer. In addition, both coagulation processes reduced the total filtration resistance, mainly the hydraulically reversible resistance and cake layer resistance, which could lower the cleaning frequency. Overall, coagulation could greatly increase the removal efficiency and improve the GDMBR

  14. Pyridostigmine prevents haemodynamic alterations but does not affect their nycthemeral oscillations in infarcted mice.

    PubMed

    Corrêa, Wesley G; Durand, Marina T; Becari, Christiane; Tezini, Geisa C S V; do Carmo, Jussara M; de Oliveira, Mauro; Prado, Cibele M; Fazan, Rubens; Salgado, Helio C

    2015-01-01

    The increase in acetylcholine yielded by pyridostigmine (PYR), an acetylcholinesterase inhibitor, was evaluated for its effect on the haemodynamic responses-mean arterial pressure (MAP) and heart rate (HR)-and their nycthemeral oscillation in mice before and one week after myocardial infarction (MI). Mice were anesthetized (isoflurane), and a telemetry transmitter was implanted into the carotid artery. After 5 days of recovery, the MAP and HR were recorded for 48 h (10 s every 10 min). Following this procedure, mice were submitted to surgery for sham or coronary artery ligation and received drinking water (VEHICLE) with or without PYR. Five days after surgery, the haemodynamic recordings were recommenced. Sham surgery combined with VEHICLE did not affect basal MAP and HR; nevertheless, these haemodynamic parameters were higher during the night, before and after surgery. MI combined with VEHICLE displayed decreased MAP and increased HR; these haemodynamic parameters were also higher during the night, before and after surgery. Sham surgery combined with PYR displayed similar results for MAP as sham combined with VEHICLE; however, PYR produced bradycardia. Nevertheless, MI combined with PYR exhibited no change in MAP and HR, but these haemodynamic parameters were also higher during the night, before and after surgery. Therefore, MI decreased MAP and increased HR, while PYR prevented these alterations. Neither MI nor PYR affected nycthemeral oscillations of MAP and HR. These findings indicate that the increase in acetylcholine yielded by PYR protected the haemodynamic alterations caused by MI in mice, without affecting the nycthemeral haemodynamic oscillations. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Influence of different computational approaches for stent deployment on cerebral aneurysm haemodynamics

    PubMed Central

    Bernardini, Annarita; Larrabide, Ignacio; Morales, Hernán G.; Pennati, Giancarlo; Petrini, Lorenza; Cito, Salvatore; Frangi, Alejandro F.

    2011-01-01

    Cerebral aneurysms are abnormal focal dilatations of artery walls. The interest in virtual tools to help clinicians to value the effectiveness of different procedures for cerebral aneurysm treatment is constantly growing. This study is focused on the analysis of the influence of different stent deployment approaches on intra-aneurysmal haemodynamics using computational fluid dynamics (CFD). A self-expanding stent was deployed in an idealized aneurysmatic cerebral vessel in two initial positions. Different cases characterized by a progression of simplifications on stent modelling (geometry and material) and vessel material properties were set up, using finite element and fast virtual stenting methods. Then, CFD analysis was performed for untreated and stented vessels. Haemodynamic parameters were analysed qualitatively and quantitatively, comparing the cases and the two initial positions. All the cases predicted a reduction of average wall shear stress and average velocity of almost 50 per cent after stent deployment for both initial positions. Results highlighted that, although some differences in calculated parameters existed across the cases based on the modelling simplifications, all the approaches described the most important effects on intra-aneurysmal haemodynamics. Hence, simpler and faster modelling approaches could be included in clinical workflow and, despite the adopted simplifications, support clinicians in the treatment planning. PMID:22670204

  16. Enzymatically oxidized phospholipids restore thrombin generation in coagulation factor deficiencies.

    PubMed

    Slatter, David A; Percy, Charles L; Allen-Redpath, Keith; Gajsiewicz, Joshua M; Brooks, Nick J; Clayton, Aled; Tyrrell, Victoria J; Rosas, Marcela; Lauder, Sarah N; Watson, Andrew; Dul, Maria; Garcia-Diaz, Yoel; Aldrovandi, Maceler; Heurich, Meike; Hall, Judith; Morrissey, James H; Lacroix-Desmazes, Sebastien; Delignat, Sandrine; Jenkins, P Vincent; Collins, Peter W; O'Donnell, Valerie B

    2018-03-22

    Hemostatic defects are treated using coagulation factors; however, clot formation also requires a procoagulant phospholipid (PL) surface. Here, we show that innate immune cell-derived enzymatically oxidized phospholipids (eoxPL) termed hydroxyeicosatetraenoic acid-phospholipids (HETE-PLs) restore hemostasis in human and murine conditions of pathological bleeding. HETE-PLs abolished blood loss in murine hemophilia A and enhanced coagulation in factor VIII- (FVIII-), FIX-, and FX-deficient human plasma . HETE-PLs were decreased in platelets from patients after cardiopulmonary bypass (CPB). To explore molecular mechanisms, the ability of eoxPL to stimulate individual isolated coagulation factor/cofactor complexes was tested in vitro. Extrinsic tenase (FVIIa/tissue factor [TF]), intrinsic tenase (FVIIIa/FIXa), and prothrombinase (FVa/FXa) all were enhanced by both HETE-PEs and HETE-PCs, suggesting a common mechanism involving the fatty acid moiety. In plasma, 9-, 15-, and 12-HETE-PLs were more effective than 5-, 11-, or 8-HETE-PLs, indicating positional isomer specificity. Coagulation was enhanced at lower lipid/factor ratios, consistent with a more concentrated area for protein binding. Surface plasmon resonance confirmed binding of FII and FX to HETE-PEs. HETE-PEs increased membrane curvature and thickness, but not surface charge or homogeneity, possibly suggesting increased accessibility to cations/factors. In summary, innate immune-derived eoxPL enhance calcium-dependent coagulation factor function, and their potential utility in bleeding disorders is proposed.

  17. Haemodynamics, dyspnoea, and pulmonary reserve in heart failure with preserved ejection fraction.

    PubMed

    Obokata, Masaru; Olson, Thomas P; Reddy, Yogesh N V; Melenovsky, Vojtech; Kane, Garvan C; Borlaug, Barry A

    2018-05-19

    Increases in left ventricular filling pressure are a fundamental haemodynamic abnormality in heart failure with preserved ejection fraction (HFpEF). However, very little is known regarding how elevated filling pressures cause pulmonary abnormalities or symptoms of dyspnoea. We sought to determine the relationships between simultaneously measured central haemodynamics, symptoms, and lung ventilatory and gas exchange abnormalities during exercise in HFpEF. Subjects with invasively-proven HFpEF (n = 50) and non-cardiac causes of dyspnoea (controls, n = 24) underwent cardiac catheterization at rest and during exercise with simultaneous expired gas analysis. During submaximal (20 W) exercise, subjects with HFpEF displayed higher pulmonary capillary wedge pressures (PCWP) and pulmonary artery pressures, higher Borg perceived dyspnoea scores, and increased ventilatory drive and respiratory rate. At peak exercise, ventilation reserve was reduced in HFpEF compared with controls, with greater dead space ventilation (higher VD/VT). Increasing exercise PCWP was directly correlated with higher perceived dyspnoea scores, lower peak exercise capacity, greater ventilatory drive, worse New York Heart Association (NYHA) functional class, and impaired pulmonary ventilation reserve. This study provides the first evidence linking altered exercise haemodynamics to pulmonary abnormalities and symptoms of dyspnoea in patients with HFpEF. Further study is required to identify the mechanisms by which haemodynamic derangements affect lung function and symptoms and to test novel therapies targeting exercise haemodynamics in HFpEF.

  18. A PK-PD model-based assessment of sugammadex effects on coagulation parameters.

    PubMed

    Bosch, Rolien; van Lierop, Marie-José; de Kam, Pieter-Jan; Kruithof, Annelieke C; Burggraaf, Jacobus; de Greef, Rik; Visser, Sandra A G; Johnson-Levonas, Amy O; Kleijn, Huub-Jan

    2016-03-10

    Exposure-response analyses of sugammadex on activated partial thromboplastin time (APTT) and prothrombin time international normalized ratio (PT(INR)) were performed using data from two clinical trials in which subjects were co-treated with anti-coagulants, providing a framework to predict these responses in surgical patients on thromboprophylactic doses of low molecular weight or unfractionated heparin. Sugammadex-mediated increases in APTT and PT(INR) were described with a direct effect model, and this relationship was similar in the presence or absence of anti-coagulant therapy in either healthy volunteers or surgical patients. In surgical patients on thromboprophylactic therapy, model-based predictions showed 13.1% and 22.3% increases in respectively APTT and PT(INR) within 30min after administration of 16mg/kg sugammadex. These increases remain below thresholds seen following treatment with standard anti-coagulant therapy and were predicted to be short-lived paralleling the rapid decline in sugammadex plasma concentrations. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Response surface methodology investigation into the interactions between arsenic and humic acid in water during the coagulation process.

    PubMed

    Watson, Malcolm Alexander; Tubić, Aleksandra; Agbaba, Jasmina; Nikić, Jasmina; Maletić, Snežana; Molnar Jazić, Jelena; Dalmacija, Božo

    2016-07-15

    Interactions between arsenic and natural organic matter (NOM) are key limiting factors during the optimisation of drinking water treatment when significant amounts of both must be removed. This work uses Response Surface Methodology (RSM) to investigate how they interact during their simultaneous removal by iron chloride coagulation, using humic acid (HA) as a model NOM substance. Using a three factor Box-Behnken experimental design, As and HA removals were modelled, as well as a combined removal response. ANOVA results showed the significance of the coagulant dose for all three responses. At high initial arsenic concentrations (200μg/l), As removal was significantly hindered by the presence of HA. In contrast, the HA removal response was found to be largely independent of the initial As concentration, with the optimum coagulant dose increasing at increasing HA concentrations. The combined response was similar to the HA removal response, and the interactions evident are most interesting in terms of optimising treatment processes during the preparation of drinking water, highlighting the importance of utilizing RSM for such investigations. The combined response model was successfully validated with two different groundwaters used for drinking water supply in the Republic of Serbia, showing excellent agreement under similar experimental conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Demonstration of the Coagulation and Diffusion of Homemade Slime Prepared under Acidic Conditions without Borate

    ERIC Educational Resources Information Center

    Isokawa, Naho; Fueda, Kazuki; Miyagawa, Korin; Kanno, Kenichi

    2015-01-01

    Poly(vinyl alcohol) (PVA) precipitates in many kinds of aqueous salt solutions. While sodium sulfate, a coagulant for PVA fiber, precipitates PVA to yield a white rigid gel, coagulation of PVA with aluminum sulfate, a coagulant for water treatment, yields a slime-like viscoelastic fluid. One type of homemade slime is prepared under basic…

  1. Polyferric sulphate: preparation, characterisation and application in coagulation experiments.

    PubMed

    Zouboulis, A I; Moussas, P A; Vasilakou, F

    2008-07-15

    The process of coagulation is a core environmental protection technology, which is mainly used in the water or wastewater treatment facilities. Research is now focused on the development of inorganic pre-polymerised coagulants. A characteristic example is PFS (polyferric sulphate), a relatively new pre-polymerised inorganic coagulant with high cationic charge. In this paper, the role of major parameters, including temperature, types of chemical reagents, ratio r=[OH]/[Fe], rate of base addition in the preparation stages of PFS were investigated. Furthermore, the prepared PFS was characterised based on typical properties, such as the percentage of the polymerised iron present in the compound, z-potential, pH, etc. Moreover, dynamics of coagulation process were examined by means of the Photometric Dispersion Analyzer (PDA). Finally, the coagulation efficiency of PFS in treating kaolin suspension and biologically pre-treated wastewater was evaluated in comparison with the respective conventional coagulant agent. The results indicate that certain parameters, such as the r value, the rate of base addition and the duration and temperature of the polymerisation stage, significantly affected the properties of the PFS. Additionally, the prepared PFS polymerised coagulants exhibit a significantly better coagulation performance than the respective non-polymerised one, i.e. ferric sulphate.

  2. Ex Vivo Liver Experiment of Hydrochloric Acid-Infused and Saline-Infused Monopolar Radiofrequency Ablation: Better Outcomes in Temperature, Energy, and Coagulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Xiong-ying; Gu, Yang-kui; Huang, Jin-hua, E-mail: huangjh@sysucc.org.cn

    ObjectiveTo compare temperature, energy, and coagulation between hydrochloric acid-infused radiofrequency ablation (HAIRFA) and normal saline-infused radiofrequency ablation (NSIRFA) in ex vivo porcine liver model.Materials and Methods30 fresh porcine livers were excised in 60 lesions, 30 with HAIRFA and the other 30 with NSIRFA. Both modalities used monopolar perfusion electrode connected to a RF generator set at 103 °C and 30 W. In each group, ablation time was set at 10, 20, or 30 min (10 lesions from each group at each time). We compared tissue temperatures (at 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 cm away from the electrode tip), average power, deposited energy,more » deposited energy per coagulation volume (DEV), coagulation diameters, coagulative volume, and spherical ratio between the two groups.ResultsTemperature–time curves showed that HAIRFA provided progressively greater heating than that of NSIRFA. At 30 min, mean average power, deposited energy, coagulation volumes (113.67 vs. 12.28 cm{sup 3}) and diameters, and increasing in tissue temperature were much greater with HAIRFA (P < 0.001 for all), except DEV was lower (456 vs. 1396 J/cm{sup 3}, P < 0.001). The spherical ratio was closer to 1 with HAIRFA (1.23 vs. 1.46). Coagulation diameters, volume, and average power of HAIRFA increased significantly with longer ablation times. While with NSIRFA, these characteristics were stable till later 20 min, except the power decreased with longer ablation times.ConclusionsHAIRFA creates much larger and more spherical lesions by increasing overall energy deposition, modulating thermal conductivity, and transferring heat during ablation.« less

  3. [Effects on phenol removal in the process of enhanced coagulation by manganese dioxide formed in situ].

    PubMed

    Zhang, Li-Zhu; Chen, Xiao-Dong; Ma, Jun; Yu, Min; Li, Xin

    2011-10-01

    Phenol was selected as a model compound. Factors, such as Ca2+, tannic acid, dose of kaolinite, dose of manganese dioxide formed in situ and pH, were invested on phenol removal in the process of enhanced coagulation by manganese dioxide formed in situ. Results showed that the addition of Ca2+ is beneficial for phenol removal. In the range of Ca2+ varied from 0 to 1.0 mmol x L(-1), the efficiency of phenol removal was enhanced more than 10%. Tannic acid can enhance phenol removal significantly when they are coexisted in water. As tannic acid was added to 10 mg x L(-1), phenol removal can be increased about 30% and 50% in the process of coagulation by AlCl3 and enhanced coagulation by manganese dioxide formed in situ, respectively. The dose of coagulant can be reduced in the process of enhanced coagulation with the addition of manganese dioxide formed in situ. The point of 1 mg x L(-1) manganese dioxide formed in situ linked with 30 mg x L(-1) AlCl3 can have the same phenol removal efficiency as the addition of 50 mg x L(-1) AlCl3. In the range of pH varied from 5 to 9, phenol can be removed with the high efficiency in the process of enhanced coagulation by manganese dioxide formed in situ. While under the strong acid condition and strong basic condition, phenol has lower removal efficiency.

  4. Application of low-mixing energy input for the coagulation process.

    PubMed

    Vadasarukkai, Yamuna S; Gagnon, Graham A

    2015-11-01

    Rapid-mixing tanks with mechanical mixers are a common design used in treatment plants. Yet, the role of such rapid-mixing systems on the effectiveness of the coagulation performance is unclear. This study looked at optimizing the direct energy used in the coagulation process for removal of natural dissolved organic matter (DOM). The role of coagulation mixing intensity (G-value) on total organic carbon (TOC) and turbidity removal was examined for the water types with high organic content, with a specific ultraviolet absorbance (SUVA) of at least 2-2.5 units of m(-1) of absorbance per mg/L. A standard jar test using ferric sulfate coagulant was performed to optimize the chemical condition in coagulation for removal of dissolved organics as well as particles. The jar test analysis at an acidic pH (4.5 ± 0.3) required an iron dose <0.3 mM to arrive at an optimal coagulant concentration and resulted in above 75% of TOC removal. The influence of coagulation mixing on TOC and turbidity removal was evaluated at G varying from 0 to 1500 s(-1) at the optimized coagulant dose and pH conditions for enhanced coagulation. In this study, a combined effective removal of TOC and turbidity was achieved at a low-mixing intensity range of 110 s(-1) < G < 450 s(-1). Coagulation operated at G greater than 450 s(-1) showed negligible improvement in TOC removal. Minimizing energy consumption in enhanced coagulation is feasible at the proposed mixing intensity range (i.e., 110 s(-1) < G < 450 s(-1)), without sacrificing the effectiveness of DOM removal by coagulation. These findings represent an opportunity for energy savings for the water industry without sacrificing quality. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Measurement of blood coagulation with considering RBC aggregation through a microchip-based light transmission aggregometer.

    PubMed

    Lim, Hyunjung; Nam, Jeonghun; Xue, Shubin; Shin, Sehyun

    2011-01-01

    Even though blood coagulation can be tested by various methods and techniques, the effect of RBC aggregation on blood coagulation is not fully understood. The present study monitored clot formation in a microchip-based light transmission aggregometer. Citrated blood samples with and without the addition of calcium ion solution were initially disaggregated by rotating a stirrer in the microchip. After abrupt stop of the rotating stirrer, the transmitted light intensity over time was recorded. The syllectogram (light intensity vs. time graph) manifested a rapid increase that is associated with RBC aggregation followed by a decrease that is associated with blood coagulation. The time to reach the peak point was used as a new index of coagulation time (CT) and ranged from 200 to 500 seconds in the present measurements. The CT was inversely proportional to the concentration of fibrinogen, which enhances RBC aggregation. In addition, the CT was inversely proportional to the hematocrit, which is similar to the case of the prothrombin time (PT), as measured by a commercial coagulometer. Thus, we carefully concluded that RBC aggregation should be considered in tests of blood coagulation.

  6. Eradication of Barrett's mucosa with argon plasma coagulation and acid suppression: immediate and mid term results

    PubMed Central

    Van Laethem, J-L; Cremer, M; Peny, M; Delhaye, M; Deviere, J

    1998-01-01

    Background—Intestinal metaplastic mucosa in Barrett's oesophagus can be replaced by squamous epithelium after mucosal thermal ablation associated with acid suppression therapy. 
Aims—To assess whether restoration of squamous epithelium can be obtained after ablation of Barrett's oesophagus using argon plasma coagulation (APC) associated with proton pump inhibitor (PPI) therapy. 
Methods—Thirty one patients with Barrett's oesophagus received APC. Omeprazole (40 mg/day) was given from the first APC application to one month after completion of the treatment, then given symptomatically. Twenty four hour pH-metry was performed during endotherapy. 
Results—Complete re-epithelialisation was visualised at endoscopy in 25/31 patients (81%) after a mean number of 2.4 APC sessions (range 1-4). Only partial squamous re-epithelialisation was observed in three patients and three others had no eradication. At histological assessment, eradication of Barrett's oesophagus was only confirmed in 19/31 patients (61%) due to the presence of a few residual Barrett's glands under the new squamous epithelium. Complete eradication was related to a Barrett's oesophagus segment length of less than 4 cm and the absence of circumferential extension but not to the normalisation of oesophageal acid exposure under PPI therapy. Seventeen patients with apparently complete endoscopic and histological eradication of Barrett's oesophagus were re-evaluated at one year; eight (47%) disclosed relapsing islands of Barrett metaplasia despite continuous omeprazole therapy (10-40 mg/day). 
Conclusions—APC combined with 40 mg omeprazole daily can eradicate Barrett's mucosa with apparent squamous re-epithelialisation in the majority of patients even in the absence of normalisation of oesophageal acid exposure. However, one year after endotherapy for Barrett's oesophagus, relapse is frequent but limited in extent. 

 Keywords: Barrett's oesophagus; argon plasma coagulation; omeprazole

  7. Influence of vegetable coagulant and ripening time on the lipolytic and sensory profile of cheeses made with raw goat milk from Canary breeds.

    PubMed

    Rincón, Arturo A; Pino, Verónica; Fresno, María R; Jiménez-Abizanda, Ana I; Álvarez, Sergio; Ayala, Juan H; Afonso, Ana M

    2017-04-01

    Free fatty acids and sensory profiles were obtained for cheeses made with raw goat milk and vegetable coagulant, derived from the cardoon flower ( Cynara cardunculus), at different ripening times (7 and 20 days). A solid-liquid phase extraction method followed by solid-phase extraction and gas chromatography was used. Profiles were also obtained with cheeses made with commercial coagulant, traditional kid rennet paste, and mixture coagulant (vegetable coagulant-kid rennet). The use of vegetable coagulant and vegetable coagulant-kid rennet is common in traditional Protected Designation of Origin cheeses such as " Queso Flor de Guía" and " Queso Media Flor de Guía" (Spain). Contents of short-chain free fatty acids (7.5-22.5 mmol·kg -1 ), medium-chain free fatty acids (0.4-3.7 mmol·kg -1 ), and long-chain free fatty acids (0.2-2.1 mmol·kg -1 ) varied depending on the coagulant type and the ripening time. Vegetable coagulant cheeses present odour intensity and flavour intensity much higher than commercial coagulant cheeses in the sensory analysis for cheeses obtained with seven days of ripening, but the values decrease when increasing the ripening time. Multivariate analysis allowed us to differentiate cheese samples according to the ripening time when using lipolytic profile and according to the coagulant type using the sensory profile.

  8. Genomic DNA Methylation Changes in Response to Folic Acid Supplementation in a Population-Based Intervention Study among Women of Reproductive Age

    PubMed Central

    Berry, Robert J.; Hao, Ling; Li, Zhu; Maneval, David; Yang, Thomas P.; Rasmussen, Sonja A.; Yang, Quanhe; Zhu, Jiang-Hui; Hu, Dale J.; Bailey, Lynn B.

    2011-01-01

    Folate is a source of one-carbons necessary for DNA methylation, a critical epigenetic modification necessary for genomic structure and function. The use of supplemental folic acid is widespread however; the potential influence on DNA methylation is unclear. We measured global DNA methylation using DNA extracted from samples from a population-based, double-blind randomized trial of folic acid supplementation (100, 400, 4000 µg per day) taken for 6 months; including a 3 month post-supplementation sample. We observed no changes in global DNA methylation in response to up to 4,000 µg/day for 6 months supplementation in DNA extracted from uncoagulated blood (approximates circulating blood). However, when DNA methylation was determined in coagulated samples from the same individuals at the same time, significant time, dose, and MTHFR genotype-dependent changes were observed. The baseline level of DNA methylation was the same for uncoagulated and coagulated samples; marked differences between sample types were observed only after intervention. In DNA from coagulated blood, DNA methylation decreased (−14%; P<0.001) after 1 month of supplementation and 3 months after supplement withdrawal, methylation decreased an additional 23% (P<0.001) with significant variation among individuals (max+17%; min-94%). Decreases in methylation of ≥25% (vs. <25%) after discontinuation of supplementation were strongly associated with genotype: MTHFR CC vs. TT (adjusted odds ratio [aOR] 12.9, 95%CI 6.4, 26.0). The unexpected difference in DNA methylation between DNA extracted from coagulated and uncoagulated samples in response to folic acid supplementation is an important finding for evaluating use of folic acid and investigating the potential effects of folic acid supplementation on coagulation. PMID:22163281

  9. Ketamine modulation of the haemodynamic response to spreading depolarization in the gyrencephalic swine brain

    PubMed Central

    Santos, Edgar; Schöll, Michael; Kunzmann, Kevin; Stock, Christian; Silos, Humberto; Unterberg, Andreas W; Sakowitz, Oliver W

    2016-01-01

    Spreading depolarization (SD) generates significant alterations in cerebral haemodynamics, which can have detrimental consequences on brain function and integrity. Ketamine has shown an important capacity to modulate SD; however, its impact on SD haemodynamic response is incompletely understood. We investigated the effect of two therapeutic ketamine dosages, a low-dose of 2 mg/kg/h and a high-dose of 4 mg/kg/h, on the haemodynamic response to SD in the gyrencephalic swine brain. Cerebral blood volume, pial arterial diameter and cerebral blood flow were assessed through intrinsic optical signal imaging and laser-Doppler flowmetry. Our findings indicate that frequent SDs caused a persistent increase in the baseline pial arterial diameter, which can lead to a diminished capacity to further dilate. Ketamine infused at a low-dose reduced the hyperemic/vasodilative response to SD; however, it did not alter the subsequent oligemic/vasoconstrictive response. This low-dose did not prevent the baseline diameter increase and the diminished dilative capacity. Only infusion of ketamine at a high-dose suppressed SD and the coupled haemodynamic response. Therefore, the haemodynamic response to SD can be modulated by continuous infusion of ketamine. However, its use in pathological models needs to be explored to corroborate its possible clinical benefit. PMID:27126324

  10. Ketamine modulation of the haemodynamic response to spreading depolarization in the gyrencephalic swine brain.

    PubMed

    Sánchez-Porras, Renán; Santos, Edgar; Schöll, Michael; Kunzmann, Kevin; Stock, Christian; Silos, Humberto; Unterberg, Andreas W; Sakowitz, Oliver W

    2017-05-01

    Spreading depolarization (SD) generates significant alterations in cerebral haemodynamics, which can have detrimental consequences on brain function and integrity. Ketamine has shown an important capacity to modulate SD; however, its impact on SD haemodynamic response is incompletely understood. We investigated the effect of two therapeutic ketamine dosages, a low-dose of 2 mg/kg/h and a high-dose of 4 mg/kg/h, on the haemodynamic response to SD in the gyrencephalic swine brain. Cerebral blood volume, pial arterial diameter and cerebral blood flow were assessed through intrinsic optical signal imaging and laser-Doppler flowmetry. Our findings indicate that frequent SDs caused a persistent increase in the baseline pial arterial diameter, which can lead to a diminished capacity to further dilate. Ketamine infused at a low-dose reduced the hyperemic/vasodilative response to SD; however, it did not alter the subsequent oligemic/vasoconstrictive response. This low-dose did not prevent the baseline diameter increase and the diminished dilative capacity. Only infusion of ketamine at a high-dose suppressed SD and the coupled haemodynamic response. Therefore, the haemodynamic response to SD can be modulated by continuous infusion of ketamine. However, its use in pathological models needs to be explored to corroborate its possible clinical benefit.

  11. Analysis of organic foulants in the coagulation-microfiltration process for the treatment of Taihu Lake.

    PubMed

    Dong, Bingzhi; Gui, Bo; Liu, Junxia; Wang, Zhihong; Tan, Kaiting

    2018-06-01

    This paper analysed organic foulants in the coagulation-microfiltration process for Taihu Lake treatment. High-performance size-exclusion chromatography (HPSEC) and fluorescence excitation-emission matrices (EEM) were applied to elucidate the influence of characteristics of organics on microfiltration (MF) membrane fouling. Results showed that coagulation pretreatment could extend the operation duration of MF based on the fact that pretreatment could effectively remove macromolecular substances as well as a portion of small molecular weight (MW) organics. The analysis of foulants indicated that organics of strong hydrophobic acids (SHA) and neutral hydrophilic (Neut) fractions (based on hydrophobicity) and medium and small MW components (based on MW distribution) contributed greatly to irreversible fouling. EEM fluorescence analysis of chemical solutions exhibited that aromatic proteins and soluble microbial products were mainly a response to irreversible fouling.

  12. Coagulation of bitumen with kaolinite in aqueous solutions containing Ca2+, Mg2+ and Fe3+: effect of citric acid.

    PubMed

    Gan, Weibing; Liu, Qi

    2008-08-01

    Heterocoagulation experiments of kaolinite with solvent-diluted-bitumen were carried out to investigate the effect of hydrolyzable metal cations and citric acid on the liberation of bitumen from kaolinite. The adsorption of Ca(2+) and Mg(2+) on kaolinite, and zeta potentials of kaolinite and bitumen droplets in solutions containing 10(-3)mol/L of Ca(2+), Mg(2+) and Fe(3+) with or without citric acid were also measured. It was found that the heterocoagulation of bitumen with kaolinite was enhanced in the presence of the metal cations from pH 7 to pH 10.5, accompanied by a decrease in the magnitude of the zeta potentials and an increase in the adsorption of the metal cations on kaolinite and possibly on bitumen droplets. The addition of 5 x 10(-4)mol/L citric acid reduced the degree of coagulation from 90% to less than 40% in the presence of 10(-3)mol/L Ca(2+) and Mg(2+) cations at pH approximately 10, and at pH approximately 8 for Fe(3+). It was found that hydrolyzable metal cations enhanced bitumen-kaolinite interactions through electrical double layer compression and specific adsorption of the metal hydrolysis species on the surface of kaolinite. The effect of metal cations was removed by citric acid through formation of metal-citrate complexes and/or the adsorption of citrate anions, which restored the zeta potentials of both kaolinite and bitumen. Therefore, electrostatic attraction or repulsion was responsible for the coagulation or dispersion of kaolinite particles from bitumen droplets in the tested system.

  13. Pleural effusion decreases left ventricular pre-load and causes haemodynamic compromise: an experimental porcine study.

    PubMed

    Wemmelund, K B; Lie, R H; Juhl-Olsen, P; Frederiksen, C A; Hermansen, J F; Sloth, E

    2012-08-01

    Although pleural effusion is a common complication in critically ill patients, detailed knowledge is missing about the haemodynamic impact and the underlining mechanisms. The aim of this study was to evaluate the haemodynamic effect of incremental pleural effusion by means of invasive haemodynamic parameters and transthoracic echocardiography. This experimental interventional study was conducted using 22 female piglets (17.5-21.5 kg) randomized for right-side (n = 9) and left-side (n = 9) pleural effusion, or sham operation (n = 4). Pleural effusion was induced by infusing incremental volumes of saline into the pleural cavity. Invasive haemodynamic measurements and echocardiographical images were obtained at baseline, a volume of 45 ml/kg, a volume of 75 ml/kg and 45 min after drainage. No difference (all P > 0.147) was found between right- and left-side pleural effusion, and the groups were thus pooled. At 45 ml/kg cardiac output, mean arterial pressure, stroke volume and mixed venous saturation decreased (all P < 0.003); central venous pressure and pulmonary arterial pressure increased (both P > 0.003) at this point. The changes accelerated at 75 ml/kg. At 45 ml/kg left ventricular pre-load in terms of end-diastolic area decreased significantly (P < 0.001). The effect on haemodynamics and cardiac dimensions changed dramatically at 75 ml/kg. Cardiac output, mean arterial pressure, central venous pressure and left ventricular end-diastolic area returned to normal during a recovery period of 45 min (all P > 0.061). Incremental volumes of unilateral pleural effusion induced a significant haemodynamic impact fully reversible after drainage. Pleural effusion causes a significant decrease of left ventricular pre-load in a diverse picture of haemodynamic compromise. © 2012 The Authors. Acta Anaesthesiologica Scandinavica © 2012 The Acta Anaesthesiologica Scandinavica Foundation.

  14. A Pontential Agriculture Waste Material as Coagulant Aid: Cassava Peel

    NASA Astrophysics Data System (ADS)

    Othman, N.; Abd-Rahim, N.-S.; Tuan-Besar, S.-N.-F.; Mohd-Asharuddin, S.; Kumar, V.

    2018-02-01

    All A large amount of cassava peel waste is generated annually by small and medium scale industries. This has led to a new policy of complete utilization of raw materials so that there will be little or no residue left that could pose pollution problems. Conversion of these by-products into a material that poses an ability to remove toxic pollutant would increase the market value and ultimately benefits the producers. This study investigated the characteristics of cassava peel as a coagulant aid material and optimization process using the cassava peel was explored through coagulation and flocculation. This research had highlighted that the Cassava peels contain sugars in the form of polysaccharides such as starch and holocellulose. The FTIR results revealed that amino acids containing abundant of carboxyl, hydroxyl and amino groups which has significant capabilities in removing pollutants. Whereas analysis by XRF spectrometry indicated that the CP samples contain Fe2O3 and Al2O3 which might contribute to its coagulation ability. The optimum condition allowed Cassava peel and alum removed high turbidity up to 90. This natural coagulant from cassava peel is found to be an alternative coagulant aid to reduce the usage of chemical coagulants

  15. Human haemodynamic frequency harmonics regulate the inflammatory phenotype of vascular endothelial cells.

    PubMed

    Feaver, Ryan E; Gelfand, Bradley D; Blackman, Brett R

    2013-01-01

    Haemodynamic variations are inherent to blood vessel geometries (such as bifurcations) and correlate with regional development of inflammation and atherosclerosis. However, the complex frequency spectrum characteristics from these haemodynamics have never been exploited to test whether frequency variations are critical determinants of endothelial inflammatory phenotype. Here we utilize an experimental Fourier transform analysis to systematically manipulate individual frequency harmonics from human carotid shear stress waveforms applied in vitro to human endothelial cells. The frequency spectrum, specifically the 0 th and 1st harmonics, is a significant regulator of inflammation, including NF-κB activity and downstream inflammatory phenotype. Further, a harmonic-based regression-model predicts eccentric NF-κB activity observed in the human internal carotid artery. Finally, short interfering RNA-knockdown of the mechanosensor PECAM-1 reverses frequency-dependent regulation of NF-κB activity. Thus, PECAM-1 may have a critical role in the endothelium's exquisite sensitivity to complex shear stress frequency harmonics and provide a mechanism for the focal development of vascular inflammation.

  16. Shock-like haemodynamic responses induced in the primary visual cortex by moving visual stimuli

    PubMed Central

    Robinson, P. A.

    2016-01-01

    It is shown that recently discovered haemodynamic waves can form shock-like fronts when driven by stimuli that excite the cortex in a patch that moves faster than the haemodynamic wave velocity. If stimuli are chosen in order to induce shock-like behaviour, the resulting blood oxygen level-dependent (BOLD) response is enhanced, thereby improving the signal to noise ratio of measurements made with functional magnetic resonance imaging. A spatio-temporal haemodynamic model is extended to calculate the BOLD response and determine the main properties of waves induced by moving stimuli. From this, the optimal conditions for stimulating shock-like responses are determined, and ways of inducing these responses in experiments are demonstrated in a pilot study. PMID:27974572

  17. Overview of the coagulation system.

    PubMed

    Palta, Sanjeev; Saroa, Richa; Palta, Anshu

    2014-09-01

    Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms 'coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same.

  18. Overview of the coagulation system

    PubMed Central

    Palta, Sanjeev; Saroa, Richa; Palta, Anshu

    2014-01-01

    Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms ‘coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same. PMID:25535411

  19. Integration of coagulation and adsorption for removal of N-nitrosodimethylamine (NDMA) precursors from biologically treated municipal wastewater.

    PubMed

    Wang, Miaomiao; Meng, Yingjie; Ma, Defang; Wang, Yan; Li, Fengli; Xu, Xing; Xia, Chufan; Gao, Baoyu

    2017-05-01

    This study investigated the N-nitrosodimethylamine (NDMA) formation potential of various dissolved organic matter (DOM) fractions in biologically treated municipal wastewater by UF fractionation, XAD-8 resin adsorption isolation, and excitation and emission matrix (EEM) fluorescence spectroscopy. Removal of various NDMA precursor fractions was also analyzed to evaluate the efficiency of traditional water treatment processes (coagulation, adsorption, and coagulation-adsorption). Results showed that NDMA were mainly formed by low molecular weight (MW) fractions (<30 kDa) and hydrophilic fractions (HiS) in biologically treated municipal wastewater. Integrated coagulation-adsorption treatments showed the highest reduction capacity for NDMA formation potential (57%), followed by isolated adsorption treatment (50%) and isolated coagulation treatment (28%). The powdered activated carbon (PAC) adsorption process could reduce the high MW precursors (>30 kDa) by 48%, which was higher than other treatments. In contrast, the highest uptake (66%) of low MW precursors (<30 kDa) was achieved by the coagulation-adsorption process. All treatments preferentially removed the hydrophobic acids (HoA) fraction compared to other fractions. Coagulation could remove more fulvic acid-like substances and adsorption could remove more microbial by-products and aromatic proteins.

  20. [Influencing factors and mechanism of arsenic removal during the aluminum coagulation process].

    PubMed

    Chen, Gui-Xia; Hu, Cheng-Zhi; Zhu, Ling-Feng; Tong, Hua-Qing

    2013-04-01

    Aluminum coagulants are widely used in arsenic (As) removal during the drinking water treatment process. Aluminium chloride (AlCl3) and polyaluminium chloride (PACl) which contains high content of Al13 were used as coagulants. The effects of aluminum species, pH, humic acid (HA) and coexisting anions on arsenic removal were investigated. Results showed that AlCl3 and PACl were almost ineffective in As(II) removal while the As(V) removal efficiency reached almost 100%. pH was an important influencing factor on the arsenic removal efficiency, because pH influenced the distribution of aluminum species during the coagulation process. The efficiency of arsenic removal by aluminum coagulants was positively correlated with the content of Al13 species. HA and some coexisting anions showed negative impact on arsenic removal because of the competitive adsorption. The negative influence of HA was more pronounced at low coagulant dosages. PO4(3-) and F(-) showed marked influence during arsenic removal, but there was no obvious influence when SiO3(2-), CO3(2-) and SO4(2-) coexisted. The present study would be helpful to direct arsenic removal by enhanced coagulation during the drinking water treatment.

  1. Coagulation management in trauma-associated coagulopathy: allogenic blood products versus coagulation factor concentrates in trauma care.

    PubMed

    Klages, Matthias; Zacharowski, Kai; Weber, Christian Friedrich

    2016-04-01

    Coagulation management by transfusion of allogenic blood products and coagulation factors are competing concepts in current trauma care. Rapid and adequate therapy of trauma-associated coagulopathy is crucial to survival of severely injured patients. Standard coagulation tests such as prothrombin time and activated partial thromboplastin time are commonly used, but these tests are inappropriate for monitoring and guiding therapy in trauma patients. Coagulation factor-based treatment showed promising results, but randomized trials have not yet been performed. In addition, viscoelastic tests are needed to guide therapy, although there is in fact limited evidence for these in tests in trauma care. Regarding transfusion therapy with allogenic blood products, plasma transfusion has been associated with improved survival in trauma patients following massive transfusion. In contrast, patients not requiring massive transfusion seem to be at risk for suffering complications with increasing volumes of plasma transfused. The collective of trauma patients is heterogeneous. Despite the lack of evidence, there are strong arguments for individualized patient treatment with coagulation factors for some indications and to abstain from the use of fresh frozen plasma. In patients with severe trauma and major bleeding, plasma, platelets, and red blood cells should be considered to be administered at a ratio of 1 : 1 : 1.

  2. Treatment of melanoidin wastewater by anaerobic digestion and coagulation.

    PubMed

    Arimi, Milton M; Zhang, Yongjun; Götz, Gesine; Geißen, Sven-Uwe

    2015-01-01

    Melanoidins are dark-coloured recalcitrant pollutants found in many industrial wastewaters including coffee-manufacturing effluent, molasses distillery wastewater (MDWW) and other wastewater with molasses as the raw material. The wastewaters are mostly treated with anaerobic digestion after some dilution to minimize the inhibition effect. However, the dark colour and recalcitrant dissolved organic carbon (DOC) mainly caused by melanoidin are not effectively removed. The aim of this study was to investigate the removal of colour and remnant DOC by different coagulants from anaerobically digested MDWW. From the six coagulants tested, ferric chloride had the highest melanoidin (48%), colour (92.7%) and DOC (63.3%) removal at pH 5 and a dosage of 1.6 g/l. Both polymer and inorganic salt coagulants tested had optimal colour, melanoidin and DOC removal at acidic pH. The molecular size distribution of synthetic melanoidins by liquid chromatography-organic carbon detection indicated a preferential removal of high-molecular-weight melanoidins over low weight melanoidins by the coagulation. Further studies should focus on how to improve biodegradability of the treated effluent for it to be reused as dilution water for anaerobic digestion.

  3. Principles of dielectric blood coagulometry as a comprehensive coagulation test.

    PubMed

    Hayashi, Yoshihito; Brun, Marc-Aurèle; Machida, Kenzo; Nagasawa, Masayuki

    2015-10-06

    Dielectric blood coagulometry (DBCM) is intended to support hemostasis management by providing comprehensive information on blood coagulation from automated, time-dependent measurements of whole blood dielectric spectra. We discuss the relationship between the series of blood coagulation reactions, especially the aggregation and deformation of erythrocytes, and the dielectric response with the help of clot structure electron microscope observations. Dielectric response to the spontaneous coagulation after recalcification presented three distinct phases that correspond to (P1) rouleau formation before the onset of clotting, (P2) erythrocyte aggregation and reconstitution of aggregates accompanying early fibrin formation, and (P3) erythrocyte shape transformation and/or structure changes within aggregates after the stable fibrin network is formed and platelet contraction occurs. Disappearance of the second phase was observed upon addition of tissue factor and ellagic acid for activation of extrinsic and intrinsic pathways, respectively, which is attributable to accelerated thrombin generation. A series of control experiments revealed that the amplitude and/or quickness of dielectric response reflect platelet function, fibrin polymerization, fibrinolysis activity, and heparin activity. Therefore, DBCM sensitively measures blood coagulation via erythrocytes aggregation and shape changes and their impact on the dielectric permittivity, making possible the development of the battery of assays needed for comprehensive coagulation testing.

  4. Laser Echosclerotherapy of varicose veins with haemodynamic echo-doppler evaluation : some rationale and short-term outcomes

    NASA Astrophysics Data System (ADS)

    Vettorello, Gianfranco; Marini, Leonardo

    2009-06-01

    Purpose: The aim is to verify short-term results in Endovenous Laser Treatment (EVLT) performed in haemodynamic way in patients belonging to C2, C3 classes and type I, II, III venous shunts, according respectively with CEAP and Teupitz classification. Methods: Minor changes of technique were applied to EVLT in order to provide haemodynamic conditions. Treatment efficacy, anatomical failure, complications, recurrence rate and clinical improvements were analyzed. 105 limbs were treated from November 2004 to November 2007. Clinical and Echo-Colour-Doppler (ECD) follow up was performed two weeks, one, two and three years after the surgery. Results: in 79 inferior limbs follow-up was concluded and this are the final data: a) no Deep Venous Thrombosis (DVT) was detected; b) a notable reduction of recurrence if compared with groin recurrence rate in traditional stripping; e) satisfactory cosmetic results and short recovery were found in all the patients. Conclusions: In selected patients haemodynamic-guided EVLT is equally safe and efficient than standard. Clinical and aesthetical outcomes are durable without statistical differences on the plan of disease progression and complications. The recurrence rate is lower in EVLT haemodynamic-guided surgery than in conventional stripping. Long-term outcomes should be investigated. We need studies camparison among the three different kind of surgery performed in haemodynamic way

  5. Numerical simulation of haemodynamics and low-density lipoprotein transport in the rabbit aorta and their correlation with atherosclerotic plaque thickness

    PubMed Central

    Liu, Xiao; Zhang, Peng; Feng, Chenglong; Sun, Anqiang; Kang, Hongyan; Deng, Xiaoyan; Fan, Yubo

    2017-01-01

    Two mechanisms of shear stress and mass transport have been recognized to play an important role in the development of localized atherosclerosis. However, their relationship and roles in atherogenesis are still obscure. It is necessary to investigate quantitatively the correlation among low-density lipoproteins (LDL) transport, haemodynamic parameters and plaque thickness. We simulated blood flow and LDL transport in rabbit aorta using computational fluid dynamics and evaluated plaque thickness in the aorta of a high-fat-diet rabbit. The numerical results show that regions with high luminal LDL concentration tend to have severely negative haemodynamic environments (HEs). However, for regions with moderately and slightly high luminal LDL concentration, the relationship between LDL concentration and the above haemodynamic indicators is not clear cut. Point-by-point correlation with experimental results indicates that severe atherosclerotic plaque corresponds to high LDL concentration and seriously negative HEs, less severe atherosclerotic plaque is related to either moderately high LDL concentration or moderately negative HEs, and there is almost no atherosclerotic plaque in regions with both low LDL concentration and positive HEs. In conclusion, LDL distribution is closely linked to blood flow transport, and the synergetic effects of luminal surface LDL concentration and wall shear stress-based haemodynamic indicators may determine plaque thickness. PMID:28424305

  6. Removal of algal blooms from freshwater by the coagulation-magnetic separation method.

    PubMed

    Liu, Dan; Wang, Peng; Wei, Guanran; Dong, Wenbo; Hui, Franck

    2013-01-01

    This research investigated the feasibility of changing waste into useful materials for water treatment and proposed a coagulation-magnetic separation technique. This technique was rapid and highly effective for clearing up harmful algal blooms in freshwater and mitigating lake eutrophication. A magnetic coagulant was synthesized by compounding acid-modified fly ash with magnetite (Fe(3)O(4)). Its removal effects on algal cells and dissolved organics in water were studied. After mixing, coagulation, and magnetic separation, the flocs obtained from the magnet surface were examined by SEM. Treated samples were withdrawn for the content determination of chlorophyll-a, turbidity, chemical oxygen demand (COD), total nitrogen, and total phosphorus. More than 99 % of algal cells were removed within 5 min after the addition of magnetic coagulant at optimal loadings (200 mg L(-1)). The removal efficiencies of COD, total nitrogen, and phosphorus were 93, 91, and 94 %, respectively. The mechanism of algal removal explored preliminarily showed that the magnetic coagulant played multiple roles in mesoporous adsorption, netting and bridging, as well as high magnetic responsiveness to a magnetic field. The magnetic-coagulation separation method can rapidly and effectively remove algae from water bodies and greatly mitigate eutrophication of freshwater using a new magnetic coagulant. The method has good performance, is low cost, can turn waste into something valuable, and provides reference and directions for future pilot and production scale-ups.

  7. [Coagulation Monitoring and Bleeding Management in Cardiac Surgery].

    PubMed

    Bein, Berthold; Schiewe, Robert

    2018-05-01

    The transfusion of allogeneic blood products is associated with increased morbidity and mortality. An impaired hemostasis is frequently found in patients undergoing cardiac surgery and may in turn cause bleeding and transfusions. A goal directed coagulation management addressing the often complex coagulation disorders needs sophisticated diagnostics. This may improve both patients' outcome and costs. Recent data suggest that coagulation management based on a rational algorithm is more effective than traditional therapy based on conventional laboratory variables such as PT and INR. Platelet inhibitors, cumarins, direct oral anticoagulants and heparin need different diagnostic and therapeutic approaches. An algorithm specifically developed for use during cardiac surgery is presented. Georg Thieme Verlag KG Stuttgart · New York.

  8. Coagulation Factor Tests

    MedlinePlus

    ... your coagulation factors. Coagulation factors are known by Roman numerals (I, II VIII, etc.) or by name ( ... need this test if you have a family history of bleeding disorders. Most bleeding disorders are inherited . ...

  9. Imaging of blood plasma coagulation at supported lipid membranes.

    PubMed

    Faxälv, Lars; Hume, Jasmin; Kasemo, Bengt; Svedhem, Sofia

    2011-12-15

    The blood coagulation system relies on lipid membrane constituents to act as regulators of the coagulation process upon vascular trauma, and in particular the 2D configuration of the lipid membranes is known to efficiently catalyze enzymatic activity of blood coagulation factors. This work demonstrates a new application of a recently developed methodology to study blood coagulation at lipid membrane interfaces with the use of imaging technology. Lipid membranes with varied net charges were formed on silica supports by systematically using different combinations of lipids where neutral phosphocholine (PC) lipids were mixed with phospholipids having either positively charged ethylphosphocholine (EPC), or negatively charged phosphatidylserine (PS) headgroups. Coagulation imaging demonstrated that negatively charged SiO(2) and membrane surfaces exposing PS (obtained from liposomes containing 30% of PS) had coagulation times which were significantly shorter than those for plain PC membranes and EPC exposing membrane surfaces (obtained from liposomes containing 30% of EPC). Coagulation times decreased non-linearly with increasing negative surface charge for lipid membranes. A threshold value for shorter coagulation times was observed below a PS content of ∼6%. We conclude that the lipid membranes on solid support studied with the imaging setup as presented in this study offers a flexible and non-expensive solution for coagulation studies at biological membranes. It will be interesting to extend the present study towards examining coagulation on more complex lipid-based model systems. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Removal of inorganic mercury and methylmercury from surface waters following coagulation of dissolved organic matter with metal-based salts

    USGS Publications Warehouse

    Henneberry, Y.K.; Kraus, T.E.C.; Fleck, J.A.; Krabbenhoft, D.P.; Bachand, P.M.; Horwath, W.R.

    2011-01-01

    The presence of inorganic mercury (IHg) and methylmercury (MeHg) in surface waters is a health concern worldwide. This study assessed the removal potential use of metal-based coagulants as a means to remove both dissolved IHg and MeHg from natural waters and provides information regarding the importance of Hg associations with the dissolved organic matter (DOM) fraction and metal hydroxides. Previous research indicated coagulants were not effective at removing Hg from solution; however these studies used high concentrations of Hg and did not reflect naturally occurring concentrations of Hg. In this study, water collected from an agricultural drain in the Sacramento-San Joaquin Delta was filtered to isolate the dissolved organic matter (DOM) fraction. The DOM was then treated with a range of coagulant doses to determine the efficacy of removing all forms of Hg from solution. Three industrial-grade coagulants were tested: ferric chloride, ferric sulfate, and polyaluminum chloride. Coagulation removed up to 85% of DOM from solution. In the absence of DOM, all three coagulants released IHg into solution, however in the presence of DOM the coagulants removed up to 97% of IHg and 80% of MeHg. Results suggest that the removal of Hg is mediated by DOM-coagulant interactions. There was a preferential association of IHg with the more aromatic, higher molecular weight fraction of DOM but no such relationship was found for MeHg. This study offers new fundamental insights regarding large-scale removal of Hg at environmentally relevant regarding large-scale removal of Hg at environmentally relevant concentrations.

  11. Bitter tastants alter gastric-phase postprandial haemodynamics.

    PubMed

    McMullen, Michael K; Whitehouse, Julie M; Whitton, Peter A; Towell, Anthony

    2014-07-03

    Since Greco-Roman times bitter tastants have been used in Europe to treat digestive disorders, yet no pharmacological mechanism has been identified which can account for this practice. This study investigates whether the bitter tastants, gentian root (Gentian lutea L.) and wormwood herb (Artemisia absinthium L.), stimulate cephalic and/or gut receptors to alter postprandial haemodynamics during the gastric-phase of digestion. Normal participants ingested (1) 100 mL water plus capsules containing either cellulose (placebo-control) or 1000 mg of each tastant (n=14); or (2) 100mL of water flavoured with 500 or 1500 mg of each tastant (a) gentian (n=12) and (b) wormwood (n=12). A single beat-to-beat cardiovascular recording was obtained for the entire session. Pre/post-ingestion contrasts with the control were analysed for (1) the encapsulated tastants, in the "10 to 15" minute post-ingestion period, and (2) the flavoured water in the "5 to 10" minute post-ingestion period. Water, the placebo-control, increased cardiac contraction force and blood pressure notwithstanding heart rate decreases. Encapsulated tastants did not further alter postprandial haemodynamics. In contrast gentian (500 and 1500 mg) and wormwood (1500 mg) flavoured water elicited increased peripheral vascular resistance and decreased cardiac output, primarily by reducing stroke volume rather than heart rate. Drinking 100mL water elicits a pressor effect during the gastric-phase of digestion due to increased cardiac contraction force. The addition of bitter tastants to water elicits an additional and parallel pressor effect due to increased peripheral vascular resistance; yet the extent of the post-prandial blood pressure increases are unchanged, presumably due to baroreflex buffering. The vascular response elicited by bitter tastants can be categorised as a sympathetically-mediated cephalic-phase response. A possible mechanism by which bitter tastants could positively influence digestion is altering

  12. Development of a magnetic coagulant based on Moringa oleifera seed extract for water treatment.

    PubMed

    Santos, Tássia R T; Silva, Marcela F; Nishi, Leticia; Vieira, Angélica M S; Fagundes-Klen, Márcia R; Andrade, Murilo B; Vieira, Marcelo F; Bergamasco, Rosângela

    2016-04-01

    In this work, to evaluate the effectiveness of the coagulation/flocculation using a natural coagulant, using Moringa oleifera Lam functionalized with magnetic iron oxide nanoparticles, producing flakes that are attracted by an external magnetic field, thereby allowing a fast settling and separation of the clarified liquid, is proposed. The removal efficiency of the parameters, apparent color, turbidity, and compounds with UV254nm absorption, was evaluated. The magnetic functionalized M. oleifera Lam coagulant could effectively remove 90 % of turbidity, 85 % of apparent color, and 50 % for the compounds with absorption at UV254nm, in surface waters under the influence of an external magnetic field within 30 min. It was found that the coagulation/flocculation treatment using magnetic functionalized M. oleifera Lam coagulant was able to reduce the values of the physico-chemical parameters evaluated with reduced settling time.

  13. Comparison of Moringa stenopetala seed extract as a clean coagulant with Alum and Moringa stenopetala-Alum hybrid coagulant to remove direct dye from Textile Wastewater.

    PubMed

    Dalvand, Arash; Gholibegloo, Elham; Ganjali, Mohammad Reza; Golchinpoor, Najmeh; Khazaei, Mohammad; Kamani, Hossein; Hosseini, Sara Sadat; Mahvi, Amir Hossein

    2016-08-01

    In this study, the efficiency of Moringa stenopetala seed extract was compared with alum and M. stenopetala-alum hybrid coagulant to remove Direct Red 23 azo dye from textile wastewater. The effects of parameters such as pH, coagulant dose, type of salt used for the extraction of coagulant and initial dye concentration on dye removal efficiency were investigated. Moreover, the existing functional groups on the structure of M. stenopetala coagulant (MSC) were determined by Fourier transform infrared spectroscopy, and the morphology of sludge produced by MSC, alum, and hybrid coagulant was characterized by scanning electron microscopy. Ninhydrin test was also used to determine the quantity of primary amines in the MSC and Moringa oleifera coagulant (MOC). According to the results, with increasing the coagulant dose and decreasing the initial dye concentration, dye removal efficiency has increased. The maximum dye removal of 98.5, 98.2, and 98.3 % were obtained by using 240, 120, and 80 mg/L MSC, alum and hybrid coagulant at pH 7, respectively. The results also showed MSC was much more effective than MOC for dye removal. The volume of sludge produced by MSC was one fourth and half of those produced by alum and hybrid coagulant, respectively. Based on the results, hybrid coagulant was the most efficient coagulant for direct dye removal from colored wastewater.

  14. Ocular haemodynamic changes after single treatment with photodynamic therapy assessed with non-invasive techniques.

    PubMed

    Maar, Noemi; Pemp, Berthold; Kircher, Karl; Luksch, Alexandra; Weigert, Günther; Polska, Elzbieta; Tittl, Michael; Stur, Michael; Schmetterer, Leopold

    2009-09-01

    To investigate in patients with neovascular age-related macular degeneration (ARMD) the changes in ocular perfusion caused by single treatment with photodynamic therapy (PDT) by different non-invasive methods; to evaluate correlations between relative changes of ocular haemodynamic parameters after PDT among each other and compared to morphological parameters; and to assess this in relation to early changes of visual acuity. 17 consecutive patients with subfoveal choroidal neovascularization (CNV) caused by ARMD scheduled for PDT without previous PDT treatment (four patients with predominantly classic CNV and 13 patients with occult CNV). best-corrected visual acuity (before PDT, 6 and 8 weeks after PDT), fundus photography, fluorescein angiography, haemodynamic measurements with laser Doppler flowmetry (LDF), laser interferometry and ocular blood flow (OBF) tonometry (baseline and 1, 2, 6 and 8 weeks after treatment). choroidal blood flow (CHBF), fundus pulsation amplitude (FPA), pulsatile ocular blood flow (POBF), visual acuity. Changes smaller than 20% were considered clinically irrelevant. Ocular haemodynamic parameters did not change significantly in the follow-up period. Changes of haemodynamic parameters showed no correlation to treatment spot, morphological changes or visual acuity. Changes of visual acuity were comparable to results of earlier studies. Single treatment with PDT did not modify ocular blood flow parameters above 20% as assessed with different non-invasive methods.

  15. Reuse of acid coagulant-recovered drinking waterworks sludge residual to remove phosphorus from wastewater

    NASA Astrophysics Data System (ADS)

    Yang, Lan; Wei, Jie; Zhang, Yumei; Wang, Jianli; Wang, Dongtian

    2014-06-01

    Acid coagulant-recovered drinking waterworks sludge residual (DWSR) is a waste product from drinking waterworks sludge (DWS) treatment with acid for coagulant recovery. In this study, we evaluated DWSR as a potential phosphorus (P) removing material in wastewater treatment by conducting a series of batch and semi-continuous tests. Batch tests were carried out to study the effects of pH, initial concentration, and sludge dose on P removal. Batch test results showed that the P removal efficiency of DWSR was highly dependent on pH. Calcinated DWSR (C-DWSR) performed better in P removal than DWSR due to its higher pH. At an optimum initial pH value of 5-6 and a sludge dose of 10 g/L, the P removal rates of DWSR and DWS decreased from 99% and 93% to 84% and 14%, respectively, and the specific P uptake of DWSR and DWS increased from 0.19 and 0.19 mg P/g to 33.60 and 5.72 mg P/g, respectively, when the initial concentration was increased from 2 to 400 mg/L. The effective minimum sludge doses of DWSR and DWS were 0.5 g/L and 10 g/L, respectively, when the P removal rates of 90% were obtained at an initial concentration of 10 mg/L. Results from semi-continuous test indicated that P removal rates over 99% were quickly achieved for both synthetic and actual wastewater (lake water and domestic sewage). These rates could be maintained over a certain time under a certain operational conditions including sludge dose, feed flow, and initial concentration. The physicochemical properties analysis results showed that the contents of aluminum (Al) and iron (Fe) in DWSR were reduced by 50% and 70%, respectively, compared with DWS. The insoluble Al and Fe hydroxide in DWS converted into soluble Al and Fe in DWSR. Metal leaching test results revealed that little soluble Al and Fe remained in effluent when DWSR was used for P removal. We deduced that chemical precipitation might be the major action for P removal by DWSR and that adsorption played only a marginal role.

  16. Enzymatically oxidized phospholipids restore thrombin generation in coagulation factor deficiencies

    PubMed Central

    Slatter, David A.; Percy, Charles L.; Allen-Redpath, Keith; Gajsiewicz, Joshua M.; Brooks, Nick J.; Tyrrell, Victoria J.; Lauder, Sarah N.; Watson, Andrew; Dul, Maria; Garcia-Diaz, Yoel; Aldrovandi, Maceler; Heurich, Meike; Hall, Judith; Lacroix-Desmazes, Sebastien; Delignat, Sandrine; Jenkins, P. Vincent; Collins, Peter W.; O’Donnell, Valerie B.

    2018-01-01

    Hemostatic defects are treated using coagulation factors; however, clot formation also requires a procoagulant phospholipid (PL) surface. Here, we show that innate immune cell–derived enzymatically oxidized phospholipids (eoxPL) termed hydroxyeicosatetraenoic acid–phospholipids (HETE-PLs) restore hemostasis in human and murine conditions of pathological bleeding. HETE-PLs abolished blood loss in murine hemophilia A and enhanced coagulation in factor VIII- (FVIII-), FIX-, and FX-deficient human plasma . HETE-PLs were decreased in platelets from patients after cardiopulmonary bypass (CPB). To explore molecular mechanisms, the ability of eoxPL to stimulate individual isolated coagulation factor/cofactor complexes was tested in vitro. Extrinsic tenase (FVIIa/tissue factor [TF]), intrinsic tenase (FVIIIa/FIXa), and prothrombinase (FVa/FXa) all were enhanced by both HETE-PEs and HETE-PCs, suggesting a common mechanism involving the fatty acid moiety. In plasma, 9-, 15-, and 12-HETE-PLs were more effective than 5-, 11-, or 8-HETE-PLs, indicating positional isomer specificity. Coagulation was enhanced at lower lipid/factor ratios, consistent with a more concentrated area for protein binding. Surface plasmon resonance confirmed binding of FII and FX to HETE-PEs. HETE-PEs increased membrane curvature and thickness, but not surface charge or homogeneity, possibly suggesting increased accessibility to cations/factors. In summary, innate immune-derived eoxPL enhance calcium-dependent coagulation factor function, and their potential utility in bleeding disorders is proposed. PMID:29563336

  17. [Effects of liensinine on haemodynamics in rats and the physiologic properties of isolated rabbit atria].

    PubMed

    Wang, J L; Nong, Y; Jing, M X

    1992-01-01

    Liensinine(Lien), an alkaloid extracted from the green seed embryo of Nelumbo nucifera Gaertn, has been shown to have anti-arrhythmic action, its mechanism may be related to blockade of Ca2+, Na+ influx. Lien 3 mg/kg i.v. may temporarily inhibit all parameters of haemodynamics in anesthetized or pithed rats. The inhibitory effects on LVP, +dp/dtmax and SAP in anesthetized rats are slightly stronger than those of quinidine (Qui) 3 mg/kg. Lien 1-30 mg/kg dose-dependently produced these actions. Lien and Qui 12 mg/kg lowered LVP, +dp/dtmax and SAP by 33%, 37%, 29% and 9%, 12%, 9% respectively. While both of them inhibited the other parameters of haemodynamics with nearly equal degrees. The degrees of inhibitory effect of Lien 12 mg/kg on all haemodynamic parameters nearly corresponded to these of verapamil 1 mg/kg. Lien 1-100 mumol/L reduced the contractile force of isolated left atria and the spontaneously beating rate of isolated right atria of rabbits in concentration-dependent manner. These results indicate that the properties of the effect of Lien on haemodynamics may be similar to those of verapamil and different from those of Qui.

  18. A new approach using coagulation rate constant for evaluation of turbidity removal

    NASA Astrophysics Data System (ADS)

    Al-Sameraiy, Mukheled

    2017-06-01

    Coagulation-flocculation-sedimentation processes for treating three levels of bentonite synthetic turbid water using date seeds (DS) and alum (A) coagulants were investigated in the previous research work. In the current research, the same experimental results were used to adopt a new approach on a basis of using coagulation rate constant as an investigating parameter to identify optimum doses of these coagulants. Moreover, the performance of these coagulants to meet (WHO) turbidity standard was assessed by introducing a new evaluating criterion in terms of critical coagulation rate constant (kc). Coagulation rate constants (k2) were mathematically calculated in second order form of coagulation process for each coagulant. The maximum (k2) values corresponded to doses, which were obviously to be considered as optimum doses. The proposed criterion to assess the performance of coagulation process of these coagulants was based on the mathematical representation of (WHO) turbidity guidelines in second order form of coagulation process stated that (k2) for each coagulant should be ≥ (kc) for each level of synthetic turbid water. For all tested turbid water, DS coagulant could not satisfy it. While, A coagulant could satisfy it. The results obtained in the present research are exactly in agreement with the previous published results in terms of finding optimum doses for each coagulant and assessing their performances. On the whole, it is recommended considering coagulation rate constant to be a new approach as an indicator for investigating optimum doses and critical coagulation rate constant to be a new evaluating criterion to assess coagulants' performance.

  19. Relation between exercise central haemodynamic response and resting cardiac structure and function in young healthy men.

    PubMed

    Babcock, Matthew C; Lefferts, Wesley K; Heffernan, Kevin S

    2017-07-01

    Left ventricular (LV) structure and function are predictors of cardiovascular (CV) morbidity and mortality and are related to resting peripheral haemodynamic load in older adults. The central haemodynamic response to exercise may reveal associations with LV structure and function not detected by traditional peripheral (brachial) measures in a younger population. To examine correlations between acute exercise-induced changes in central artery stiffness and wave reflections and measures of resting LV structure and function. Sixteen healthy men (age 26 ± 6 year; BMI 25·3 ± 2·7 kg m -2 ) had measures of central haemodynamic load measured before/after a 30-s Wingate anaerobic test (WAT). Common carotid artery stiffness and reflected wave intensity were assessed via wave intensity analysis as a regional pulse wave velocity (PWV) and negative area (NA), respectively. Resting LV structure (LV mass) and function [midwall fractional shortening (mFS)] were assessed using M-mode echocardiography in the parasternal short-axis view. There was a significant association between mFS and WAT-mediated change in carotid systolic BP (r = -0·57, P = 0·011), logNA (r = -0·58, P = 0·009) and PWV (r = -0·44, P = 0·045). There were no significant associations between resting mFS and changes in brachial systolic BP (r = -0·26, P>0·05). There were no associations between resting LV mass and changes in any haemodynamic variable (P>0·05). Exercise-induced increases in central haemodynamic load reveal associations with lower resting LV function in young healthy men undetected by traditional peripheral haemodynamics. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  20. Trihalomethanes (THMs) precursor fractions removal by coagulation and adsorption for bio-treated municipal wastewater: Molecular weight, hydrophobicity/hydrophily and fluorescence.

    PubMed

    Han, Qi; Yan, Han; Zhang, Feng; Xue, Nan; Wang, Yan; Chu, Yongbao; Gao, Baoyu

    2015-10-30

    Due to concerns over health risk of disinfection byproducts (DBPs), removal of trihalomethanes (THMs) precursor from bio-treated wastewater by coagulation and adsorption was investigated in this study. Ultrafiltration (UF) membranes and nonionic resins were applied to fractionate THMs precursor into various molecular weight (MW) fractions and hydrophobic/hydrophilic fractions. Characteristics of coagulated water and adsorbed water were evaluated by the three-dimensional excitation and emission matrix (3DEEM) fluorescence spectroscopy. Results showed that coagulation and adsorption were suitable for removing different hydrophobic/hydrophilic and fluorescent fractions. Coagulation decreased THMs concentration in hydrophobic acids (HoA) fraction from 59 μg/L to 39 μg/L, while the lowest THMs concentration (9 μg/L) in hydrophilic substances (HiS) fraction was obtained in adsorbed water. However, both coagulation and adsorption were ineffective for removing fractions with MW<5 kDa. Although coagulation and adsorption processes could reduce THMs formation, some specific THMs formation potential (STHMFP) in residual dissolved organic matter (DOM) fractions increased in this study. Hydrophobic acid and hydrophilic fractions increased after coagulation treatment, and low MW and hydrophobic fractions increased after adsorption treatment. In addition, active carbon adsorbed more organic matter than coagulant, but brominated disinfection byproducts (Br-DBPs) in adsorbed water turned to the major THMs species after chlorination. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Genome-wide association of coagulation properties, curd firmness modeling, protein percentage, and acidity in milk from Brown Swiss cows.

    PubMed

    Dadousis, C; Biffani, S; Cipolat-Gotet, C; Nicolazzi, E L; Rossoni, A; Santus, E; Bittante, G; Cecchinato, A

    2016-05-01

    Cheese production is increasing in many countries, and a desire toward genetic selection for milk coagulation properties in dairy cattle breeding exists. However, measurements of individual cheesemaking properties are hampered by high costs and labor, whereas traditional single-point milk coagulation properties (MCP) are sometimes criticized. Nevertheless, new modeling of the entire curd firmness and syneresis process (CFt equation) offers new insight into the cheesemaking process. Moreover, identification of genomic regions regulating milk cheesemaking properties might enhance direct selection of individuals in breeding programs based on cheese ability rather than related milk components. Therefore, the objective of this study was to perform genome-wide association studies to identify genomic regions linked to traditional MCP and new CFt parameters, milk acidity (pH), and milk protein percentage. Milk and DNA samples from 1,043 Italian Brown Swiss cows were used. Milk pH and 3 MCP traits were grouped together to represent the MCP set. Four CFt equation parameters, 2 derived traits, and protein percentage were considered as the second group of traits (CFt set). Animals were genotyped with the Illumina SNP50 BeadChip v.2 (Illumina Inc., San Diego, CA). Multitrait animal models were used to estimate variance components. For genome-wide association studies, the genome-wide association using mixed model and regression-genomic control approach was used. In total, 106 significant marker traits associations and 66 single nucleotide polymorphisms were identified on 12 chromosomes (1, 6, 9, 11, 13, 15, 16, 19, 20, 23, 26, and 28). Sharp peaks were detected at 84 to 88 Mbp on Bos taurus autosome (BTA) 6, with a peak at 87.4 Mbp in the region harboring the casein genes. Evidence of quantitative trait loci at 82.6 and 88.4 Mbp on the same chromosome was found. All chromosomes but BTA6, BTA11, and BTA28 were associated with only one trait. Only BTA6 was in common between MCP

  2. Normal Coagulation

    DTIC Science & Technology

    2014-09-04

    LO TTIN G with vitamin K antagonist...confidential until formal publication.6 F CHAPTER 34 Normal Coagulation 531 SE C T IO N 7 B LEED IN G A N D C LO TTIN G Table 34-1 Procoagulant...formal publication.8 F CHAPTER 34 Normal Coagulation 533 SE C T IO N 7 B LEED IN G A N D C LO TTIN G Figure 34-4 Vitamin K–dependent com-

  3. Haemodynamics of aerobic and resistance blood flow restriction exercise in young and older adults.

    PubMed

    Staunton, Craig A; May, Anthony K; Brandner, Christopher R; Warmington, Stuart A

    2015-11-01

    Light-load blood flow restriction exercise (BFRE) may provide a novel training method to limit the effects of age-related muscle atrophy in older adults. Therefore, the purpose of this study was to compare the haemodynamic response to resistance and aerobic BFRE between young adults (YA; n = 11; 22 ± 1 years) and older adults (OA; n = 13; 69 ± 1 years). On two occasions, participants completed BFRE or control exercise (CON). One occasion was leg press (LP; 20 % 1-RM) and the other was treadmill walking (TM; 4 km h(-1)). Haemodynamic responses (HR, Q, SV and BP) were recorded during baseline and exercise. At baseline, YA and OA were different for some haemodynamic parameters (e.g. BP, SV). The relative responses to BFRE were similar between YA and OA. Blood pressures increased more with BFRE, and also for LP over TM. Q increased similarly for BFRE and CON (in both LP and TM), but with elevated HR and reduced SV (TM only). While BFR conferred slightly greater haemodynamic stress than CON, this was lower for walking than leg-press exercise. Given similar response magnitudes between YA and OA, these data support aerobic exercise being a more appropriate BFRE for prescription in older adults that may contribute to limiting the effects of age-related muscle atrophy.

  4. Coagulation of micro-polluted Pearl River water with IPF-PACls.

    PubMed

    Xu, Yi; Sun, Wei; Wang, Dong-sheng; Tang, Hong-xiao

    2004-01-01

    Water samples collected from early March 2001 to the end of April 2002 at the branch of Pearl River around the Guangzhou City were analyzed for its micro-polluted characteristics. The coagulation behavior of polyaluminum chlorides (PACls) was then examined focusing on the effect of primary water quality and speciation distribution. The results showed that PACls exhibit better coagulation efficiency than alum in accordance with the different speciation. The turbidity removal property of PACls is evidently better than alum at low dosage. While in neutral zone (about 6.5-7.5), the turbidity removal of PACls decreases owing to the restabilization of particles at higher dosage. The organic matters in raw water exhibit marked influence on coagulation. In acidic zone, organic matters complex with polymer species and promote the formation of flocs. With an increase in pH, the complexation of organics with polymer species gradually decreases, and the removal of organics mainly depends on adsorption. The effect is evidently improved with the raise of B value.

  5. Haemodynamic predictors of a penetrating atherosclerotic ulcer rupture using fluid–structure interaction analysis

    PubMed Central

    D'Ancona, Giuseppe; Amaducci, Andrea; Rinaudo, Antonino; Pasta, Salvatore; Follis, Fabrizio; Pilato, Michele; Baglini, Roberto

    2013-01-01

    We present preliminary data on the flow-induced haemodynamic and structural loads exerted on a penetrating atherosclerotic aortic ulcer (PAU). Specifically, one-way fluid–structure interaction analysis was performed on the aortic model reconstructed from a 66-year-old male patient with a PAU that evolved into an intramural haematoma and rupture of the thoracic aorta. The results show that elevated blood pressure (117 mmHg) and low flow velocity at the aortic wall (0.15 m/s2) occurred in the region of the PAU. We also found a low value of time-averaged wall shear stress (1.24 N/m2) and a high value of the temporal oscillation in the wall shear stress (oscillatory shear index = 0.13) in the region of the PAU. After endovascular treatment, these haemodynamic parameters were distributed uniformly on the luminal surface of the stent graft. These findings suggest that wall shear stress could be considered one of the major haemodynamic factors indicating the structural fragility of the PAU wall, which ultimately lead to PAU growth and rupture. PMID:23736658

  6. Use of grape seed and its natural polyphenol extracts as a natural organic coagulant for removal of cationic dyes.

    PubMed

    Jeon, Jong-Rok; Kim, Eun-Ju; Kim, Young-Mo; Murugesan, Kumarasamy; Kim, Jae-Hwan; Chang, Yoon-Seok

    2009-11-01

    Natural organic coagulants (NOCs) such as chitosan and Moringa oleifera seeds have been extensively characterized for potential application in water treatment as an alternative to metal-based coagulants. However, the action of both chitosan and M. oleifera seeds is mainly restricted to anionic organic pollutants because of their cationic functional groups affording poor cationic pollutant coagulation by electrostatic repulsion. In this study, we employed ethanolic grape seed extract (GSE) and grape seed-derived polyphenols such as tannic acid and catechin in an effort to find novel NOCs showing stable anionic forms for removal of cationic organic pollutants. The target substances tested were malachite green (MG) and crystal violet (CV), both mutagenic cationic dyes. Polyphenol treatment induced fast decolorization followed by gradual floc formation concomitant with red or blue shifts in maximum absorbance wavelengths of the cationic dyes. Liquid chromatography analysis of flocs formed by polyphenols directly showed that initial supramolecular complexes attributed mainly to electrostatic attraction between polyphenol hydroxyphenyl groups and cationic dyes further progressed into stronger aggregates, leading to precipitation of dye-polyphenol complexes. Consistent with the results obtained using catechin and tannic acid, use of GSE also resulted in effective decolorization and coagulation of soluble MG and CV in aqueous solutions. Screening of several organic GSE components for NOC activity strongly suggested that natural polyphenols are the main organic ingredients causing MG and CV removal via gradual floc formation. The treatment by natural polyphenols and GSE decreased toxicity of MG- or CV-contaminated water.

  7. Chemical coagulation of combined sewer overflow: heavy metal removal and treatment optimization.

    PubMed

    El Samrani, A G; Lartiges, B S; Villiéras, F

    2008-02-01

    The coagulation of combined sewer overflow (CSO) was investigated by jar-testing with two commercial coagulants, a ferric chloride solution (CLARFER) and a polyaluminium chloride (WAC HB). CSO samples were collected as a function of time during various wet-weather events from the inlet of Boudonville retention basin, Nancy, France. Jar-tests showed that an efficient turbidity removal can be achieved with both coagulants, though lower optimum dosages and higher re-stabilization concentrations were obtained with the aluminum-based coagulant. Optimum turbidity removal also yielded effective heavy metal elimination. However, the evolution with coagulant dosage of Cu, Zn, Pb, Cr, soluble and suspended solids contents followed various patterns. The removal behaviors can be explained by a selective aggregation of heavy metal carriers present in CSO and a specific interaction between hydrolyzed coagulant species and soluble metals. Stoichiometric relationships were established between optimal coagulant concentration, range of optimal dosing, and CSO conductivity, thus providing useful guidelines to adjust the coagulant demand during the course of CSO events.

  8. Isolation and characterization of coagulant extracted from Moringa oleifera seed by salt solution.

    PubMed

    Okuda, T; Baes, A U; Nishijima, W; Okada, M

    2001-02-01

    It is known that M. oleifera contains a natural coagulant in the seeds. In our previous research, the method using salt water to extract the active coagulation component from M. oleifera seeds was developed and compared with the conventional method using water. In this research, the active coagulation component was purified from a NaCl solution crude extract of Moringa oleifera seeds. The active component was isolated and purified from the crude extract through a sequence of steps that included salting-out by dialysis, removal of lipids and carbohydrates by homogenization with acetone, and anion exchange. Specific coagulation activity of the active material increased up to 34 times more than the crude extract after the ion exchange. The active component was not the same as that of water extract. The molecular weight was about 3000 Da. The Lowry method and the phenol-sulfuric acid method indicated that the active component was neither protein nor polysaccharide. The optimum pH of the purified active component for coagulation of turbidity was pH 8 and above. Different from the conventional water extracts, the active component can be used for waters with low turbidity without increase in the dissolved organic carbon concentration.

  9. Electromagnetic induction sensor for dynamic testing of coagulation process.

    PubMed

    Wang, Zhe; Yu, Yuanhua; Yu, Zhanjiang; Chen, Qimeng

    2018-03-01

    With the increasing demand for coagulation POCT for patients in the surgery department or the ICU, rapid coagulation testing techniques and methods have drawn widespread attention from scholars and businessmen. This paper proposes the use of electromagnetic induction sensor probe for detection of dynamic process causing changes in the blood viscosity and density before and after coagulation based on the damped vibration principle, in order to evaluate the coagulation status. Utilizing the dynamic principle, the differential equation of vibration system comprising elastic support and electromagnetic induction device is established through sensor dynamic modeling. The structural parameters of elastic support are optimized, and the circular sheet spring is designed. Furthermore, harmonic response analysis and vibration fatigue coupling analysis are performed on the elastic support of the sensor by considering the natural frequency of the system, and the electromagnetic induction sensor testing device is set up. Using the device and coagulation reagent, the standard curve for coagulation POCT is plotted, and the blood sample application in clinical patients is established, which are methodologically compared with the imported POCT coagulation analyzer. The results show that the sensor designed in this paper has a first-order natural frequency of 11.368 Hz, which can withstand 5.295 × 10 2 million times of compressions and rebounds. Its correlation with the results of SONOCLOT analyzer reaches 0.996, and the reproducibility 0.002. The electromagnetic induction coagulation testing sensor designed has good elasticity and anti-fatigue, which can meet the accuracy requirement of clinical detection. This study provides the core technology for developing the electromagnetic induction POCT instrument for dynamic testing of coagulation process.

  10. Haemodynamic evidence for cardiac stress during transurethral prostatectomy.

    PubMed Central

    Evans, J. W.; Singer, M.; Chapple, C. R.; Macartney, N.; Walker, J. M.; Milroy, E. J.

    1992-01-01

    OBJECTIVE--To compare haemodynamic performance during transurethral prostatectomy and non-endoscopic control procedures similar in duration and surgical trauma. DESIGN--Controlled comparative study. SETTING--London teaching hospital. PATIENTS--33 men aged 50-85 years in American Society of Anesthesiologists risk groups I and II undergoing transurethral prostatectomy (20), herniorrhaphy (eight), or testicular exploration (five). MAIN OUTCOME MEASURES--Percentage change from baseline in mean arterial pressure, heart rate, Doppler indices of stroke volume and cardiac output, and index of systemic vascular resistance, and change from baseline in core temperature. RESULTS--In the control group mean arterial pressure fell to 11% (95% confidence interval -17% to -5%) below baseline at two minutes into surgery and remained below baseline; there were no other overall changes in haemodynamic variables and the core temperature was stable. During transurethral prostatectomy mean arterial pressure increased by 16% (5% to 27%) at the two minute recording and remained raised throughout. Bradycardia reached -7% (-14% to 1%) by the end of the procedure. Doppler indices of stroke volume fell progressively to 15% (-24% to -6%) below baseline at the end of the procedure, and the index of cardiac output fell to 21% (-32% to -10%) below baseline by the end of the procedure. The index of systemic vascular resistance was increased by 28% (17% to 38%) at two minutes, and by 46.8% (28% to 66%) at the end of the procedure. Core temperature fell by a mean of 0.8 (-1.0 to -0.6) degrees C. Significant differences existed between the two groups in summary measures of mean arterial pressure (p less than 0.05), Doppler indices of stroke volume (p less than 0.005) and cardiac output (p less than 0.005), index of systemic vascular resistance (p less than 0.0005), and core temperature (p less than 0.0001). CONCLUSIONS--Important haemodynamic disturbances were identified during routine apparently

  11. Enhanced coagulation for improving coagulation performance and reducing residual aluminum combining polyaluminum chloride with diatomite.

    PubMed

    Hu, Wenchao; Wu, Chunde

    2016-01-01

    The feasibility of using enhanced coagulation, which combined polyaluminum chloride (PAC) with diatomite for improving coagulation performance and reducing the residual aluminum (Al), was discussed. The effects of PAC and diatomite dosage on the coagulation performance and residual Al were mainly investigated. Results demonstrated that the removal efficiencies of turbidity, dissolved organic carbon (DOC), and UV254 were significantly improved by the enhanced coagulation, compared with PAC coagulation alone. Meaningfully, the five forms of residual Al (total Al (TAl), total dissolved Al (TDAl), dissolved organic Al (DOAl), dissolved monomeric Al (DMAl), and dissolved organic monomeric Al (DOMAl)) all had different degrees of reduction in the presence of diatomite and achieved the lowest concentrations (0.185, 0.06, 0.053, 0.014, and 0 mg L(-1), respectively) at a PAC dose of 15 mg L(-1) and diatomite dose of 40 mg L(-1). In addition, when PAC was used as coagulant, the majority of residual Al existed in dissolved form (about 31.14-70.16%), and the content of DOMAl was small in the DMAl.

  12. Measurement of Blood Coagulation Factor Synthesis in Cultures of Human Hepatocytes.

    PubMed

    Heinz, Stefan; Braspenning, Joris

    2015-01-01

    An important function of the liver is the synthesis and secretion of blood coagulation factors. Within the liver, hepatocytes are involved in the synthesis of most blood coagulation factors, such as fibrinogen, prothrombin, factor V, VII, IX, X, XI, XII, as well as protein C and S, and antithrombin, whereas liver sinusoidal endothelial cells produce factor VIII and von Willebrand factor. Here, we describe methods for the detection and quantification of most blood coagulation factors in hepatocytes in vitro. Hepatocyte cultures indeed provide a valuable tool to study blood coagulation factors. In addition, the generation and expansion of hepatocytes or hepatocyte-like cells may be used in future for cell-based therapies of liver diseases, including blood coagulation factor deficiencies.

  13. Coagulation chemistries for silica removal from cooling tower water.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nyman, May Devan; Altman, Susan Jeanne; Stewart, Tom

    2010-02-01

    The formation of silica scale is a problem for thermoelectric power generating facilities, and this study investigated the potential for removal of silica by means of chemical coagulation from source water before it is subjected to mineral concentration in cooling towers. In Phase I, a screening of many typical as well as novel coagulants was carried out using concentrated cooling tower water, with and without flocculation aids, at concentrations typical for water purification with limited results. In Phase II, it was decided that treatment of source or make up water was more appropriate, and that higher dosing with coagulants deliveredmore » promising results. In fact, the less exotic coagulants proved to be more efficacious for reasons not yet fully determined. Some analysis was made of the molecular nature of the precipitated floc, which may aid in process improvements. In Phase III, more detailed study of process conditions for aluminum chloride coagulation was undertaken. Lime-soda water softening and the precipitation of magnesium hydroxide were shown to be too limited in terms of effectiveness, speed, and energy consumption to be considered further for the present application. In Phase IV, sodium aluminate emerged as an effective coagulant for silica, and the most attractive of those tested to date because of its availability, ease of use, and low requirement for additional chemicals. Some process optimization was performed for coagulant concentration and operational pH. It is concluded that silica coagulation with simple aluminum-based agents is effective, simple, and compatible with other industrial processes.« less

  14. Theories of blood coagulation.

    PubMed

    Riddel, James P; Aouizerat, Bradley E; Miaskowski, Christine; Lillicrap, David P

    2007-01-01

    Although the concept of the coagulation cascade represented a significant advance in the understanding of coagulation and served for many years as a useful model, more recent clinical and experimental observations demonstrate that the cascade/waterfall hypothesis does not fully and completely reflect the events of hemostasis in vivo. The goal of this article is to review the evolution of the theories of coagulation and their proposed models to serve as a tool when reviewing the research and practice literature that was published in the context of these different theories over time.

  15. Competitive adsorption of PPCP and humic substances by carbon nanotube membranes: Effects of coagulation and PPCP properties.

    PubMed

    Wang, Yifei; Yang, Qing; Dong, Junqing; Huang, Haiou

    2018-04-01

    Natural organic matter (NOM) and pharmaceuticals and personal care products (PPCP) are known to compete for adsorption sites on carbon nanotubes (CNT), resulting in decreasing PPCP adsorption onto CNT. In this study, four types of PPCP, as such acetaminophen (AAP), caffeine (CAF), triclosan (TCS), and carbendazim (CBD) were used to investigate the effects of PPCP properties and NOM coagulation on the competitive adsorption of PPCP and NOM. Coagulation preferentially removed HS from a natural surface water, thereby increasing adsorption of AAP, CAF, TCS and CBD by 19%, 13%, 17% and 11%, respectively. Similar trends were obtained with synthetic natural waters, for which the adsorption of AAP, CAF, TCS, and CBD increased by 29%, 7%, 44% and 69%, respectively, as humic acid (HA) concentration decreased from 10mgL -1 to 0mgL -1 . Furthermore, PPCP properties also affected their competition with NOM for adsorption by CNT membranes Because CAF existed in cationic form at pH ranging from 7 to 8.3, its adsorption was less affected by the presence/coagulation of NOM than AAP, CBD, and TCS. Based upon these findings, coagulation has the potential to be integrated with CNT adsorption for the removal of PPCP compounds during advanced drinking water treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Retardation effect of different alcohols on the cement coagulation in polycarboxylate- and naphthalene-based cement admixtures

    NASA Astrophysics Data System (ADS)

    Huang, S. M.; Zhou, F. L.

    2017-12-01

    Alcohol has great potential to delay the coagulation of cement. The effects of alcohol on paste fluidity and normal consistency coagulation time have been studied for polycarboxylate superplasticizer and naphthene cement admixture. Seven alcohols were combined with polycarboxylate superplasticizer and naphthene at a concentration of 0.01-0.09%, respectively, including n-propanol, methanol, sorbitol, ethylene glycol, glycerol, ethanol, and mannitol. The fluidity and normal consistency coagulation time of each cement admixture were measured. The performance of both polycarboxylate superplasticizer and naphthene cement admixtures were compared to develop cement admixture with delayed coagulation.

  17. Comparison of the effects of antihypertensive treatment with angiotensin II blockade and beta-blockade on carotid wall structure and haemodynamics: protocol and baseline demographics.

    PubMed

    Ariff, Ben; Stanton, Alice; Barratt, Dean; Augst, Alex; Glor, Fadi; Poulter, Neil; Sever, Peter; Xu, Yun; Hughes, Alun; Thom, Simon A Mc G

    2002-06-01

    Several systemic factors have been shown to contribute to the acceleration of large vessel atheroma. Correction of these factors leads to a reduction in the progression of plaque formation and associated arterial wall thickness. Atheroma remains, however, a focal disease, developing at characteristic sites within the arterial tree. These sites are typically at areas of vessel branching or marked curvature, and correspond to regions of high tensile stress and low sheer stress, leading to the hypothesis that local haemodynamic factors and vessel wall mechanics potentiate the focal development of atheroma. Current assessment of vascular haemodynamics suffers from an inability to handle complex flow, and does not allow accurate determination of locally varying flow, and shear stress patterns. The application of computational fluid dynamic (CFD) flow simulation techniques to ultrasound and local pressure data, however, allows a comprehensive, non-invasive appraisal of haemodynamic flow parameters to be performed. The Candesartan cilexetil and Atenolol Carotid Haemodynamic Endpoint Trial (CACHET) study compares the effects of two antihypertensive regimens, one b-blocker-based, the other angiotensin receptor blocker based, on carotid intima-media thickness. The collection of ultrasound and pressure data on each subject provides a unique opportunity to apply these data to the CFD model to study the effects of these antihypertensive regimens on local fluid dynamics. This will lead to a greater understanding of the relationship of these factors to atheroma formation and regression.

  18. The impact of phosphate-balanced crystalloid infusion on acid-base homeostasis (PALANCE study): study protocol for a randomized controlled trial.

    PubMed

    Pagel, Judith-Irina; Hulde, Nikolai; Kammerer, Tobias; Schwarz, Michaela; Chappell, Daniel; Burges, Alexander; Hofmann-Kiefer, Klaus; Rehm, Markus

    2017-07-10

    This study aims to investigate the effects of a modified, balanced crystalloid including phosphate in a perioperative setting in order to maintain a stable electrolyte and acid-base homeostasis in the patient. This is a single-centre, open-label, randomized controlled trial involving two parallel groups of female patients comparing a perioperative infusion regime with sodium glycerophosphate and Jonosteril® (treatment group) or Jonosteril® (comparator) alone. The primary endpoint is to maintain a stable concentration of weak acids [A - ] according to the Stewart approach of acid-base balance. Secondary endpoints are measurement of serum phosphate levels, other acid-base parameters such as the strong ion difference (SID), the onset and severity of postoperative nausea and vomiting (PONV), electrolyte levels and their excretion in the urine, monitoring of renal function and glycocalyx components, haemodynamics, amounts of catecholamines and other vasopressors used and the safety of the infusion regime. Perioperative fluid replacement with the use of currently available crystalloid preparations still fail to maintain a stable acid-base balance and experts agree that common balanced solutions are still not ideal. This study aims to investigate the effectivity and safety of a new crystalloid solution by adding sodium glycerophosphate to a standardized crystalloid preparation in order to maintain a balanced perioperative acid-base homeostasis. EudraCT number 201002422520 . Registered on 30 November 2010.

  19. Utilization of Drinking Water Treatment Slurry to Produce Aluminum Sulfate Coagulant.

    PubMed

    Fouad, Mahmoud M; Razek, Taha M A; Elgendy, Ahmed S

    2017-02-01

      In Egypt, water treatment consumes about 365 000 tons of aluminum sulfate and produces more than 100 million tons of sludge per year. The common disposal system of sludge in Egypt is to discharge it into natural waterways. Toxicity of aluminum, environmental regulations and costs of chemicals used in water treatment and sludge treatment processes led to an evaluation of coagulant recovery and subsequent reuse. The present work aimed at aluminum recovery from sludge of El-Shiekh Zayd water treatment plant (WTP) to produce aluminum sulfate coagulant. Sludge was characterized and the effect of five variables was tested and the process efficiency was evaluated at different operating conditions. Maximum recovery is 94.2% at acid concentration 1.5 N, sludge weight 5 g, mixing speed 60 rpm, temperature 60 °C and leaching time 40 min. Then optimum conditions were applied to get maximum recovery for aluminum sulfate and compared to commercial coagulant on raw water of El-Shiekh Zayd (WTP).

  20. Effective removal of contaminants in landfill leachate membrane concentrates by coagulation.

    PubMed

    Long, Yuyang; Xu, Jing; Shen, Dongsheng; Du, Yao; Feng, Huajun

    2017-01-01

    Leachate membrane concentrates containing high concentrations of organics and trace toxic compounds pose a major threat to the environment, and their treatment is an urgent issue. In this work, various coagulants were used to treat leachate membrane concentrates. Appropriate pH values for treatments with FeCl 2 , FeSO 4 , polyaluminum chloride, and FeCl 3 were 3, 5, 5, and 4, respectively. FeCl 3 achieved the highest total organic carbon (TOC) removal efficiency. The effect of the various anions in ferric coagulants [FeCl 3 , Fe 2 (SO 4 ) 3 , and Fe(NO 3 ) 3 ] on the TOC removal efficiency was negligible. The main organics remaining in the leachate membrane concentrates after coagulation were humic and fulvic acids. The conditions for coagulation with FeCl 3 were optimized using the response surface method (RSM). The highest TOC, chemical oxygen demand (COD), and chromaticity reduction efficiencies, 81%, 82%, and 97%, respectively, were achieved at pH 4 using FeCl 3 (5 g L -1 ) and polyacrylamide (PAM; 0.07 g L -1 ). The COD of leachate membrane concentrates was reduced from 4000 to 718 mg L -1 . The mole ratio of removed COD and Fe(III) (2.4 mol) at 5 g L -1 FeCl 3 (pH 4, PAM 0.07 g L -1 ) was lower than that (3.8 mol) at 3 g L -1 FeCl 3 (pH 4, PAM 0.07 g L -1 ); based on the cost and COD removal efficiency, the latter conditions were the best choice. Our work provides guidelines for the treatment of leachate membrane concentrates in engineering. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Haemodynamic changes in hepatocellular carcinoma and liver parenchyma under balloon occlusion of the hepatic artery.

    PubMed

    Sugihara, Fumie; Murata, Satoru; Ueda, Tatsuo; Yasui, Daisuke; Yamaguchi, Hidenori; Miki, Izumi; Kawamoto, Chiaki; Uchida, Eiji; Kumita, Shin-Ichiro

    2017-06-01

    To investigate haemodynamic changes in hepatocellular carcinoma (HCC) and liver under hepatic artery occlusion. Thirty-eight HCC nodules in 25 patients were included. Computed tomography (CT) during hepatic arteriography (CTHA) with and without balloon occlusion of the hepatic artery was performed. CT attenuation and enhancement volume of HCC and liver with and without balloon occlusion were measured on CTHA. Influence of balloon position (segmental or subsegmental branch) was evaluated based on differences in HCC-to-liver attenuation ratio (H/L ratio) and enhancement volume of HCC and liver. In the segmental group (n = 20), H/L ratio and enhancement volume of HCC and liver were significantly lower with balloon occlusion than without balloon occlusion. However, in the subsegmental group (n = 18), H/L ratio was significantly higher and liver enhancement volume was significantly lower with balloon occlusion; HCC enhancement volume was similar with and without balloon occlusion. Rate of change in H/L ratio and enhancement volume of HCC and liver were lower in the segmental group than in the subsegmental group. There were significantly more perfusion defects in HCC in the segmental group. Hepatic artery occlusion causes haemodynamic changes in HCC and liver, especially with segmental occlusion. • Hepatic artery occlusion causes haemodynamic changes in hepatocellular carcinoma and liver. • Segmental occlusion decreased rate of change in hepatocellular carcinoma-to-liver attenuation ratio. • Subsegmental occlusion increased rate of change in hepatocellular carcinoma-to-liver attenuation ratio. • Hepatic artery occlusion decreased enhancement volume of hepatocellular carcinoma and liver. • Hepatic artery occlusion causes perfusion defects in hepatocellular carcinoma.

  2. Evaluating the roles of detailed endocardial structures on right ventricular haemodynamics by means of CFD simulations.

    PubMed

    Sacco, Federica; Paun, Bruno; Lehmkuhl, Oriol; Iles, Tinen L; Iaizzo, Paul A; Houzeaux, Guillaume; Vázquez, Mariano; Butakoff, Constantine; Aguado-Sierra, Jazmin

    2018-06-11

    Computational modelling plays an important role in right ventricular (RV) haemodynamic analysis. However, current approaches employ smoothed ventricular anatomies. The aim of this study is to characterise RV haemodynamics including detailed endocardial structures like trabeculae, moderator band and papillary muscles (PMs). Four paired detailed and smoothed RV endocardium models (two male and two female) were reconstructed from ex-vivo human hearts high-resolution magnetic resonance images (MRI). Detailed models include structures with ≥1 mm 2 cross-sectional area. Haemodynamic characterisation was done by computational fluid dynamics (CFD) simulations with steady and transient inflows, using high performance computing (HPC). The differences between the flows in smoothed and detailed models were assessed using Q-criterion for vorticity quantification, the pressure drop between inlet and outlet, and the wall shear stress (WSS). Results demonstrated that detailed endocardial structures increase the degree of intra-ventricular pressure drop, decrease the WSS and disrupt the dominant vortex creating secondary small vortices. Increasingly turbulent blood flow was observed in the detailed RVs. Female RVs were less trabeculated and presented lower pressure drops than the males. In conclusion, neglecting endocardial structures in RV haemodynamic models may lead to inaccurate conclusions about the pressures, stresses, and blood flow behaviour in the cavity. This article is protected by copyright. All rights reserved.

  3. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring for surgical hip repair in two patients with severe aortic stenosis.

    PubMed

    López, María Mercedes; Guasch, Emilia; Schiraldi, Renato; Maggi, Genaro; Alonso, Eduardo; Gilsanz, Fernando

    2016-01-01

    Aortic stenosis increases perioperative morbidity and mortality, perioperative invasive monitoring is advised for patients with an aortic valve area <1.0 cm(2) or a mean aortic valve gradient >30 mmHg and it is important to avoid hypotension and arrhythmias. We report the anaesthetic management with continuous spinal anaesthesia and minimally invasive haemodynamic monitoring of two patients with severe aortic stenosis undergoing surgical hip repair. Two women with severe aortic stenosis were scheduled for hip fracture repair. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring was used for anaesthetic management of both. Surgery was performed successfully after two consecutive doses of 2mg of isobaric bupivacaine 0.5% in one of them and four consecutive doses in the other. Haemodynamic conditions remained stable throughout the intervention. Vital signs and haemodynamic parameters remained stable throughout the two interventions. Our report illustrates the use of continuous spinal anaesthesia with minimally invasive haemodynamic monitoring as a valid alternative to general or epidural anaesthesia in two patients with severe aortic stenosis who are undergoing lower limb surgery. However, controlled clinical trials would be required to establish that this technique is safe and effective in these type or patients. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  4. A data-driven approach for the study of coagulation phenomena in waste lubricant oils and its relevance in alkaline regeneration treatments.

    PubMed

    Pinheiro, C T; Ascensão, V R; Reis, M S; Quina, M J; Gando-Ferreira, L M

    2017-12-01

    Coagulation phenomena can occur in certain types of waste lubricant oils (WLO) during regeneration processes involving alkaline treatments, causing plant shutdowns. In this context, this study addresses the nature of the compounds responsible for the coagulation phenomena after the alkaline treatment. For such, an empirical test was developed to assess the coagulation behaviour of WLO, consisting in the addition of KOH to the WLO followed by heating under stirring conditions. This test was performed on 133 samples and four coagulation classes were identified: A; B1; B2 and C. Moreover, a physicochemical characterization of WLO was carried out regarding viscosity at 40°C, saponification number (SN), total acid number (TAN), surface tension, water content, elemental analysis and functional groups (FTIR). 56 samples of fresh lubricant oils for different applications were also characterized and their properties assessed and compared. Multivariate methods were applied to WLO to discriminate among coagulation classes based on FTIR spectra. It was found that coagulation classes A and B1 exhibit statistically similar patterns for all properties determined. Spectral discriminating analysis did not reveal discriminant peaks for class B1 samples, and the presence of specific additives was pointed as the possible factor underlying the increase in viscosity in this oils. Class B2 presents the absence of additives and oxidation products as differentiating features. In addition, B2 samples showed lower TAN SN, and lower concentration of some elements. Lubricants from gear or hydraulic applications can give rise to this class of WLO. Oils of Class C are mainly composed by synthetic ester type base oils, which hamper regeneration processes using alkaline pretreatments. In future studies, WLO type A and B1 can be classified as a single class. The coagulation phenomena classification becomes A - negative, B - precipitate formation and C - positive. Copyright © 2017 Elsevier B

  5. Membrane fouling control and enhanced removal of pharmaceuticals and personal care products by coagulation-MBR.

    PubMed

    Park, Junwon; Yamashita, Naoyuki; Tanaka, Hiroaki

    2018-04-01

    We investigated the effects of the addition of two coagulants-polyaluminium chloride (PACl) and chitosan-into the membrane bioreactor (MBR) process on membrane fouling and the removal of pharmaceuticals and personal care products (PPCPs). Their addition at optimized dosages improved the permeability of the membrane by reducing the concentration of soluble microbial products in mixed liquor, the content of inorganic elements, and irreversible fouling of the membrane surface. During long-term operation, the addition of PACl increased removal efficiencies of tetracycline, mefenamic acid, atenolol, furosemide, ketoprofen, and diclofenac by 17-23%. The comparative evaluation using mass balance calculations between coagulation-MBR (with PACl addition) and control-MBR (without PACl addition) showed that enhanced biodegradability played a key role in improving removal efficiencies of some PPCPs in coagulation-MBR. Coagulation-MBR also had higher oxygen uptake rates and specific nitrification rates of microorganisms. Overall, our findings suggest that the combination of MBR with coagulation reduced membrane fouling, lengthening operation period of the membrane, and improved the removal of some PPCPs as a result of enhanced biodegradability. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Comparison of non-invasive methods for the assessment of haemodynamic drug effects in healthy male and female volunteers: sex differences in cardiovascular responsiveness.

    PubMed Central

    Wolzt, M; Schmetterer, L; Rheinberger, A; Salomon, A; Unfried, C; Breiteneder, H; Ehringer, H; Eichler, H G; Fercher, A F

    1995-01-01

    1. The study was performed to determine the sensitivity and short-term and day-to-day variability of a novel technique based on laser interferometry of ocular fundus pulsations and of non-invasive methods for the quantification of haemodynamic drug effects. An additional aim was to assess sex differences in haemodynamic responsiveness to cardiovascular drugs in male and female healthy volunteers. 2. Ten males and nine females (age range 20-33 years) were studied in a double-blind, randomized, cross-over trial. Simultaneous measurements from systemic haemodynamics, laser interferometry of ocular fundus pulsations, systolic time intervals from mechanocardiography, a/b ratio from oxymetric fingerplethysmography and Doppler sonography of the radial artery were used to describe the haemodynamic effects of cumulative, stepwise increasing intravenous doses of phenylephrine, isoprenaline, sodium nitroprusside and of placebo. 3. Laser interferometry detected the isoprenaline-effects at the lowest dose level of 0.1 micrograms min-1 with a high signal-to-noise ratio. The reproducibility of measurements under baseline was high, no changes were observed after systemically effective doses of phenylephrine or sodium nitroprusside. Systolic time intervals were sensitive and specific for isoprenaline-induced effects, PEP and QS2c-measurements had high reproducibility. Fingerplethysmography proved a sensitive measurement for the detection of the vasodilating effects of sodium nitroprusside, but was not specific, and showed low reproducibility. Measurements from Doppler sonography had lower reproducibility and sensitivity compared with the other applied methods. 4. There was a significant sex difference for several of the haemodynamic parameters under baseline conditions; however, the responsiveness to the drugs under study was not different, when drug effects were expressed as %-change from the baseline. 5. Laser interferometry is a valuable non-invasive, highly sensitive and

  7. Dust coagulation in ISM

    NASA Technical Reports Server (NTRS)

    Chokshi, Arati; Tielens, Alexander G. G. M.; Hollenbach, David

    1989-01-01

    Coagulation is an important mechanism in the growth of interstellar and interplanetary dust particles. The microphysics of the coagulation process was theoretically analyzed as a function of the physical properties of the coagulating grains, i.e., their size, relative velocities, temperature, elastic properties, and the van der Waal interaction. Numerical calculations of collisions between linear chains provide the wave energy in individual particles and the spectrum of the mechanical vibrations set up in colliding particles. Sticking probabilities are then calculated using simple estimates for elastic deformation energies and for the attenuation of the wave energy due to absorption and scattering processes.

  8. Wetlands receiving water treated with coagulants improve water quality by removing dissolved organic carbon and disinfection byproduct precursors.

    PubMed

    Hansen, Angela M; Kraus, Tamara E C; Bachand, Sandra M; Horwath, William R; Bachand, Philip A M

    2018-05-01

    Constructed wetlands are used worldwide to improve water quality while also providing critical wetland habitat. However, wetlands have the potential to negatively impact drinking water quality by exporting dissolved organic carbon (DOC) that upon disinfection can form disinfection byproducts (DBPs) like trihalomethanes (THMs) and haloacetic acids (HAAs). We used a replicated field-scale study located on organic rich soils in California's Sacramento-San Joaquin Delta to test whether constructed flow-through wetlands which receive water high in DOC that is treated with either iron- or aluminum-based coagulants can improve water quality with respect to DBP formation. Coagulation alone removed DOC (66-77%) and THM (67-70%) precursors, and was even more effective at removing HAA precursors (77-90%). Passage of water through the wetlands increased DOC concentrations (1.5-7.5mgL -1 ), particularly during the warmer summer months, thereby reversing some of the benefits from coagulant addition. Despite this addition, water exiting the wetlands treated with coagulants had lower DOC and DBP precursor concentrations relative to untreated source water. Benefits of the coagulation-wetland systems were greatest during the winter months (approx. 50-70% reduction in DOC and DBP precursor concentrations) when inflow water DOC concentrations were higher and wetland DOC production was lower. Optical properties suggest DOC in this system is predominantly comprised of high molecular weight, aromatic compounds, likely derived from degraded peat soils. Published by Elsevier B.V.

  9. Freedom Solo® versus Trifecta® bioprostheses: clinical and haemodynamic evaluation after propensity score matching.

    PubMed

    Cerqueira, Rui J; Raimundo, Renata; Moreira, Soraia; Saraiva, Francisca A; Andrade, Marta; Salgueiro, Elson; Almeida, Jorge; Amorim, Mário Jorge; Pinho, Paulo; Lourenço, André P; Leite-Moreira, Adelino

    2018-01-16

    The goal of this study was to compare the stentless Freedom Solo® (FS) and the stented Trifecta® (TF) aortic bioprostheses with regard to haemodynamic profile, left ventricular mass regression and early and late postoperative outcomes and survival. A longitudinal cohort study of consecutive patients undergoing aortic valve replacement (2009-16) with either the FS or TF at 1 centre was performed. Local databases and national records were queried. Prosthesis haemodynamics and left ventricular dimensions were obtained from postoperative echocardiograms. After propensity score matching (21 covariates), the Kaplan-Meier and competing risk analyses were performed for survival and the combined outcome of structural valve deterioration and endocarditis, respectively. Haemodynamics and mass regression were assessed by a mixed-effects model including propensity score as a covariate. From a total sample of 397 patients with the FS and 525 TF bioprostheses with a median follow-up time of 4.0 (2.2-6.0) and 2.4 (1.4-3.7) years, respectively, a matched sample of 329 pairs was obtained. Matched groups showed no differences in survival (hazard ratio = 1.04, 95% confidence interval = 0.69-1.56) or cumulative hazards of combined outcome (subdistribution hazard ratio = 0.54, 95% confidence interval = 0.21-1.39). Although the TF showed an improved haemodynamic profile, no difference was found in mass regression. Patients with TF bioprostheses had higher rates of prolonged mechanical ventilation, whereas patients with the FS bioprosthesis showed higher rates of thrombocytopenia. The TF showed an improved haemodynamic profile compared to the FS, but this did not translate into further reverse remodelling. Postoperative outcomes and survival rates were comparable for both bioprostheses. Long-term follow-up is needed for comparisons with classical bioprosthesis models. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for

  10. Coagulation-flocculation mechanisms in wastewater treatment plants through zeta potential measurements.

    PubMed

    López-Maldonado, E A; Oropeza-Guzman, M T; Jurado-Baizaval, J L; Ochoa-Terán, A

    2014-08-30

    Based on the polyelectrolyte-contaminant physical and chemical interactions at the molecular level, this article analyzed and discussed the coagulation-flocculation and chemical precipitation processes in order to improve their efficiency. Bench experiments indicate that water pH, polyelectrolyte (PE) dosing strategy and cationic polyelectrolyte addition are key parameters for the stability of metal-PE complexes. The coagulation-flocculation mechanism is proposed based on zeta potential (ζ) measurement as the criteria to define the electrostatic interaction between pollutants and coagulant-flocculant agents. Polyelectrolyte and wastewater dispersions are exposed to an electrophoretic effect to determine ζ. Finally, zeta potential values are compared at pH 9, suggesting the optimum coagulant dose at 162mg/L polydadmac and 67mg/L of flocculant, since a complete removal of TSS and turbidity is achieved. Based on the concentration of heavy metals (0.931mg/L Sn, 0.7mg/L Fe and 0.63mg/L Pb), treated water met the Mexican maximum permissible limits. In addition, the treated water has 45mg O2/L chemical oxygen demand (COD) and 45mg C/L total organic carbon (TOC). The coagulation-flocculation mechanism is proposed taking into account both: zeta potential (ζ)-pH measurement and chemical affinity, as the criteria to define the electrostatic and chemical interaction between pollutants and polyelectrolytes. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Mesenchymal stem cells correct haemodynamic dysfunction associated with liver injury after extended resection in a pig model.

    PubMed

    Tautenhahn, Hans-Michael; Brückner, Sandra; Uder, Christiane; Erler, Silvio; Hempel, Madlen; von Bergen, Martin; Brach, Janine; Winkler, Sandra; Pankow, Franziska; Gittel, Claudia; Baunack, Manja; Lange, Undine; Broschewitz, Johannes; Dollinger, Matthias; Bartels, Michael; Pietsch, Uta; Amann, Kerstin; Christ, Bruno

    2017-06-01

    In patients, acute kidney injury (AKI) is often due to haemodynamic impairment associated with hepatic decompensation following extended liver surgery. Mesenchymal stem cells (MSCs) supported tissue protection in a variety of acute and chronic diseases, and might hence ameliorate AKI induced by extended liver resection. Here, 70% liver resection was performed in male pigs. MSCs were infused through a central venous catheter and haemodynamic parameters as well as markers of acute kidney damage were monitored under intensive care conditions for 24 h post-surgery. Cytokine profiles were established to anticipate the MSCs' potential mode of action. After extended liver resection, hyperdynamic circulation, associated with hyponatraemia, hyperkalaemia, an increase in serum aldosterone and low urine production developed. These signs of hepatorenal dysfunction and haemodynamic impairment were corrected by MSC treatment. MSCs elevated PDGF levels in the serum, possibly contributing to circulatory homeostasis. Another 14 cytokines were increased in the kidney, most of which are known to support tissue regeneration. In conclusion, MSCs supported kidney and liver function after extended liver resection. They probably acted through paracrine mechanisms improving haemodynamics and tissue homeostasis. They might thus provide a promising strategy to prevent acute kidney injury in the context of post-surgery acute liver failure.

  12. Investigating the influence of haemodynamic stimuli on intracranial aneurysm inception.

    PubMed

    Chen, Haoyu; Selimovic, Alisa; Thompson, Harry; Chiarini, Alessandro; Penrose, Justin; Ventikos, Yiannis; Watton, Paul N

    2013-07-01

    We propose a novel method to reconstruct the hypothetical geometry of the healthy vasculature prior to intracranial aneurysm (IA) formation: a Frenet frame is calculated along the skeletonization of the arterial geometry; upstream and downstream boundaries of the aneurysmal segment are expressed in terms of the local Frenet frame basis vectors; the hypothetical healthy geometry is then reconstructed by propagating a closed curve along the skeleton using the local Frenet frames so that the upstream boundary is smoothly morphed into the downstream boundary. This methodology takes into account the tortuosity of the arterial vasculature and requires minimal user subjectivity. The method is applied to 22 clinical cases depicting IAs. Computational fluid dynamic simulations of the vasculature without IA are performed and the haemodynamic stimuli in the location of IA formation are examined. We observe that locally elevated wall shear stress (WSS) and gradient oscillatory number (GON) are highly correlated (20/22 for WSS and 19/22 for GON) with regions susceptible to sidewall IA formation whilst haemodynamic indices associated with the oscillation of the WSS vectors have much lower correlations.

  13. Utilization of wasted cockle shell as a natural coagulant and a neutralizer of polluted water in Bangka Belitung islands, Indonesia

    NASA Astrophysics Data System (ADS)

    Tiandho, Y.; Aldila, H.; Mustari; Megiyo; Afriani, F.

    2018-05-01

    Bangka Belitung Islands is the largest tin producer in Indonesia. The high activity of tin mining caused the environmental damage which had an impact on the emergence of clean water crisis in some areas in this province. In this paper, a simple water quality improvement method based on wasted cockle shell was developed. Based on x-ray diffraction analysis it is known that calcination of cockle shell powder at 700°C will decompose the powder into calcium oxide compound. The addition of calcined cockle shell powder into acidic water from Merawang Sub-district will increase the pH of water through the process of forming hydroxide groups in the water. The calcined cockle shell powder can also coagulate pollutants in some polluted water from Koba Sub-district. The coagulation results were analyzed using SEM/EDS.

  14. Structural characterization of coagulant Moringa oleifera Lectin and its effect on hemostatic parameters.

    PubMed

    Luz, Luciana de Andrade; Silva, Mariana Cristina Cabral; Ferreira, Rodrigo da Silva; Santana, Lucimeire Aparecida; Silva-Lucca, Rosemeire Aparecida; Mentele, Reinhard; Oliva, Maria Luiza Vilela; Paiva, Patricia Maria Guedes; Coelho, Luana Cassandra Breitenbach Barroso

    2013-07-01

    Lectins are carbohydrate recognition proteins. cMoL, a coagulant Moringa oleifera Lectin, was isolated from seeds of the plant. Structural studies revealed a heat-stable and pH resistant protein with 101 amino acids, 11.67 theoretical pI and 81% similarity with a M. oleifera flocculent protein. Secondary structure content was estimated as 46% α-helix, 12% β-sheets, 17% β-turns and 25% unordered structures belonging to the α/β tertiary structure class. cMoL significantly prolonged the time required for blood coagulation, activated partial thromboplastin (aPTT) and prothrombin times (PT), but was not so effective in prolonging aPTT in asialofetuin presence. cMoL acted as an anticoagulant protein on in vitro blood coagulation parameters and at least on aPTT, the lectin interacted through the carbohydrate recognition domain. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Assessing blood coagulation status with laser speckle rheology

    PubMed Central

    Tripathi, Markandey M.; Hajjarian, Zeinab; Van Cott, Elizabeth M.; Nadkarni, Seemantini K.

    2014-01-01

    We have developed and investigated a novel optical approach, Laser Speckle Rheology (LSR), to evaluate a patient’s coagulation status by measuring the viscoelastic properties of blood during coagulation. In LSR, a blood sample is illuminated with laser light and temporal speckle intensity fluctuations are measured using a high-speed CMOS camera. During blood coagulation, changes in the viscoelastic properties of the clot restrict Brownian displacements of light scattering centers within the sample, altering the rate of speckle intensity fluctuations. As a result, blood coagulation status can be measured by relating the time scale of speckle intensity fluctuations with clinically relevant coagulation metrics including clotting time and fibrinogen content. Our results report a close correlation between coagulation metrics measured using LSR and conventional coagulation results of activated partial thromboplastin time, prothrombin time and functional fibrinogen levels, creating the unique opportunity to evaluate a patient’s coagulation status in real-time at the point of care. PMID:24688816

  16. Emergent self-similarity of cluster coagulation

    NASA Astrophysics Data System (ADS)

    Pushkin, Dmtiri O.

    A wide variety of nonequilibrium processes, such as coagulation of colloidal particles, aggregation of bacteria into colonies, coalescence of rain drops, bond formation between polymerization sites, and formation of planetesimals, fall under the rubric of cluster coagulation. We predict emergence of self-similar behavior in such systems when they are 'forced' by an external source of the smallest particles. The corresponding self-similar coagulation spectra prove to be power laws. Starting from the classical Smoluchowski coagulation equation, we identify the conditions required for emergence of self-similarity and show that the power-law exponent value for a particular coagulation mechanism depends on the homogeneity index of the corresponding coagulation kernel only. Next, we consider the current wave of mergers of large American banks as an 'unorthodox' application of coagulation theory. We predict that the bank size distribution has propensity to become a power law, and verify our prediction in a statistical study of the available economical data. We conclude this chapter by discussing economically significant phenomenon of capital condensation and predicting emergence of power-law distributions in other economical and social data. Finally, we turn to apparent semblance between cluster coagulation and turbulence and conclude that it is not accidental: both of these processes are instances of nonlinear cascades. This class of processes also includes river network formation models, certain force-chain models in granular mechanics, fragmentation due to collisional cascades, percolation, and growing random networks. We characterize a particular cascade by three indicies and show that the resulting power-law spectrum exponent depends on the indicies values only. The ensuing algebraic formula is remarkable for its simplicity.

  17. [Coagulation and adsorption on treating the Yellow River and the impact on chlorine decay during chlorination process].

    PubMed

    Zhan, Xiao; Gao, Bao-yu; Liu, Bin; Xu, Chun-hua; Yue, Qin-yan

    2010-05-01

    Two types of inorganic polymer coagulants, polyferric chloride (PFC) and polyaluminum chloride (PAC), were chosen to treat the Yellow River water. Different dosages were investigated in order to investigate the turbidity, UV24, DOC and permanganate index removal efficiency and their coagulation mechanisms based on the Zeta potentials. The natural organic matter removal by the combination of coagulation and adsorption with powder activated carbon were analyzed based on different coagulant and adsorbent dosages and dosing orders. The effects of combination of coagulation and adsorption on the residual chlorine decay were analyzed. The results showed that the two coagulants had high turbidity removal efficiency ( > 90%). The UV254, DOC, permanganate index removal efficiency were 29.2%, 26.1% and 27.9% respectively for PAC coagulation and were 32.3%, 23.3% and 32.9% respectively for PFC. Electric neutralization played an important role in the PAC coagulation process while both adsorption bridging and electric neutralization performed when PFC was used. The removal percentage of organic matter increased with the increase coagulant and adsorbent. The adsorption after coagulation process gave the better UV254 and DOC removal efficiency than the coagulation after adsorption. The UV254 and DOC removal efficiency were 95.2% and 99.9% for PAC coagulation after adsorption and were 90.1% and 99.9% for PFC coagulation first. But adding powder activated carbon can improve floc settlement performance and maintained persistent disinfection effect.

  18. Application of response surface methodology (RSM) for optimizing coagulation process of paper recycling wastewater using Ocimum basilicum.

    PubMed

    Mosaddeghi, Mohammad Reza; Pajoum Shariati, Farshid; Vaziri Yazdi, Seyed Ali; Nabi Bidhendi, Gholamreza

    2018-06-21

    The wastewater produced in a pulp and paper industry is one of the most polluted industrial wastewaters, and therefore its treatment requires complex processes. One of the simple and feasible processes in pulp and paper wastewater treatment is coagulation and flocculation. Overusing a chemical coagulant can produce a large volume of sludge and increase costs and health concerns. Therefore, the use of natural and plant-based coagulants has been recently attracted the attention of researchers. One of the advantages of using Ocimum basilicum as a coagulant is a reduction in the amount of chemical coagulant required. In this study, the effect of basil mucilage has been investigated as a plant-based coagulant together with alum for treatment of paper recycling wastewater. Response surface methodology (RSM) was used to optimize the process of chemical coagulation based on a central composite rotatable design (CCRD). Quadratic models for colour reduction and TSS removal with coefficients of determination of R 2 >96 were obtained using the analysis of variance. Under optimal conditions, removal efficiencies of colour and total suspended solids (TSS) were 85% and 82%, respectively.

  19. Mapping cortical haemodynamics during neonatal seizures using diffuse optical tomography: A case study

    PubMed Central

    Singh, Harsimrat; Cooper, Robert J.; Wai Lee, Chuen; Dempsey, Laura; Edwards, Andrea; Brigadoi, Sabrina; Airantzis, Dimitrios; Everdell, Nick; Michell, Andrew; Holder, David; Hebden, Jeremy C.; Austin, Topun

    2014-01-01

    Seizures in the newborn brain represent a major challenge to neonatal medicine. Neonatal seizures are poorly classified, under-diagnosed, difficult to treat and are associated with poor neurodevelopmental outcome. Video-EEG is the current gold-standard approach for seizure detection and monitoring. Interpreting neonatal EEG requires expertise and the impact of seizures on the developing brain remains poorly understood. In this case study we present the first ever images of the haemodynamic impact of seizures on the human infant brain, obtained using simultaneous diffuse optical tomography (DOT) and video-EEG with whole-scalp coverage. Seven discrete periods of ictal electrographic activity were observed during a 60 minute recording of an infant with hypoxic–ischaemic encephalopathy. The resulting DOT images show a remarkably consistent, high-amplitude, biphasic pattern of changes in cortical blood volume and oxygenation in response to each electrographic event. While there is spatial variation across the cortex, the dominant haemodynamic response to seizure activity consists of an initial increase in cortical blood volume prior to a large and extended decrease typically lasting several minutes. This case study demonstrates the wealth of physiologically and clinically relevant information that DOT–EEG techniques can yield. The consistency and scale of the haemodynamic responses observed here also suggest that DOT–EEG has the potential to provide improved detection of neonatal seizures. PMID:25161892

  20. Numerical investigation of the coagulation mixing between dust and hygroscopic aerosol particles and its impacts

    NASA Astrophysics Data System (ADS)

    Tsai, I.-Chun; Chen, Jen-Ping; Lin, Yi-Chiu; Chung-Kuang Chou, Charles; Chen, Wei-Nai

    2015-05-01

    A statistical-numerical aerosol parameterization was incorporated into the Community Multiscale Air Quality modeling system to study the coagulation mixing process focusing on a dust storm event that occurred over East Asia. Simulation results show that the coagulation mixing process tends to decrease aerosol mass, surface area, and number concentrations over the dust source areas. Over the downwind oceanic areas, aerosol concentrations generally increased due to enhanced sedimentation as particles became larger upon coagulation. The mixture process can reduce the overall single-scattering albedo by up to 10% as a result of enhanced core with shell absorption by dust and reduction in the number of scattering particles. The enhanced dry deposition speed also altered the vertical distribution. In addition, the ability of aerosol particles to serve as cloud condensation nuclei (CCN) increased from around 107 m-3 to above 109 m-3 over downwind areas because a large amount of mineral dust particles became effective CCN with solute coating, except over the highly polluted areas where multiple collections of hygroscopic particles by dust in effect reduced CCN number. This CCN effect is much stronger for coagulation mixing than by the uptake of sulfuric acid gas on dust, although the nitric acid gas uptake was not investigated. The ability of dust particles to serve as ice nuclei may decrease or increase at low or high subzero temperatures, respectively, due to the switching from deposition nucleation to immersion freezing or haze freezing.

  1. Histology assessment of bipolar coagulation and argon plasma coagulation on digestive tract

    PubMed Central

    Garrido, Teresa; Baba, Elisa R; Wodak, Stephanie; Sakai, Paulo; Cecconello, Ivan; Maluf-Filho, Fauze

    2014-01-01

    AIM: To analyze the effect of bipolar electrocoagulation and argon plasma coagulation on fresh specimens of gastrointestinal tract. METHODS: An experimental evaluation was performed at Hospital das Clinicas of the University of São Paulo, on 31 fresh surgical specimens using argon plasma coagulation and bipolar electrocoagulation at different time intervals. The depth of tissue damage was histopathologically analyzed by single senior pathologist unaware of the coagulation method and power setting applied. To analyze the results, the mucosa was divided in superficial mucosa (epithelial layer of the esophagus and superficial portion of the glandular layer of the stomach and colon) intermediate mucosa (until the lamina propria of the esophagus and until the bottom of the glandular layer of the stomach and colon) and muscularis mucosa. Necrosis involvement of the layers was compared in several combinations of power and time interval. RESULTS: Involvement of the intermediate mucosa of the stomach and of the muscularis mucosa of the three organs was more frequent when higher amounts of energy were used with argon plasma. In the esophagus and in the colon, injury of the intermediate mucosa was frequent, even when small amounts of energy were used. The use of bipolar electrocoagulation resulted in more frequent involvement of the intermediate mucosa and of the muscularis mucosa of the esophagus and of the colon when higher amounts of energy were used. In the stomach, these involvements were rare. The risk of injury of the muscularis propria was significant only in the colon when argon plasma coagulation was employed. CONCLUSION: Tissue damage after argon plasma coagulation is deeper than bipolar electrocoagulation. Both of them depend on the amount of energy used. PMID:25031789

  2. Calcium contained tap water phenomena: students misconception patterns of acids-bases concept

    NASA Astrophysics Data System (ADS)

    Liliasari, S.; Albaiti, A.; Wahyudi, A.

    2018-05-01

    Acids and bases concept is very important and fundamental concept in learning chemistry. It is one of the chemistry subjects considered as an abstract and difficult concept to understand. The aim of this research was to explore student’s misconception pattern about acids and bases phenomena in daily life, such as calcium contained tap water. This was a qualitative research with descriptive methods. Participants were 546 undergraduate students of chemistry education and chemistry program, and graduate students of chemistry education in West Java, Indonesia. The test to explore students’ misconception about this phenomena was essay test. The results showed that there were five patterns of students’ misconception in explaining the phenomena of calcium carbonate precipitation on heating tap water. Students used irrelevant concepts in explaining this phenomena, i.e. temporary hardness, coagulation, density, and phase concepts. No students had right answer in explaining this phenomena. This research contributes to design meaningful learning and to achieve better understanding.

  3. Direct observation on the Brownian coagulation of PSL particles through optical microscope in the regime near critical coagulation concentration (CCC).

    PubMed

    Fukasawa, Tomonori; Adachi, Yasuhisa

    2010-04-15

    Microscopic monitoring of floc structure, floc size distribution and the rate of coagulation was carried out for Brownian coagulation of PSL particles. Experiments were designed for the condition of salt concentration that is slightly below critical coagulation concentration (CCC). The density of the solvent was controlled by using deuterium oxide (D(2)O) to avoid sedimentation. Results are summarized as follows: (i) Near CCC, floc restructuring from the beginning stage of coagulation was evidenced, i.e., the ratio of linear triplet is found to be remarkably reduced as compared with the result obtained for the case of rapid coagulation which was implemented under sufficiently high salt concentration. (ii) The increase of fractal dimension from 1.8 in the case of rapid coagulation to 2.2 was confirmed by the analysis of mass balance using size distribution of flocs. This increment resulted in the decrease of effective excluded volume of flocs. (iii) The rate of coagulation was constant until later stage. This result contrasts to the result of rapid coagulation [T. Fukasawa, Y. Adachi, J. Colloid Interface Sci. 304 (2006) 115]. 2010 Elsevier Inc. All rights reserved.

  4. A Systematic Review and Meta-Analysis of the Haemodynamic Effects of Cannabidiol

    PubMed Central

    Sultan, Salahaden R.; Millar, Sophie A.; England, Timothy J.; O'Sullivan, Saoirse E.

    2017-01-01

    Despite cannabidiol (CBD) having numerous cardiovascular effects in vitro, its haemodynamic effects in vivo are unclear. Nonetheless, the clinical use of CBD (Epidiolex) is becoming more widespread. The aim of this systematic review was to establish whether CBD is associated with changes in haemodynamics in vivo. Twenty-five studies that assessed the haemodynamic effects of CBD (from PubMed, Medline and EMBASE) were systematically reviewed and meta-analyzed. Data on blood pressure (BP), heart rate (HR), and blood flow (BF) were extracted and analyzed using random effects models. Twenty-two publications assessed BP and HR among 6 species (BP n = 344 and HR n = 395), and 5 publications assessed BF in 3 species (n = 56) after acute dosing of CBD. Chronic dosing was assessed in 4 publications in 3 species (total subjects BP, n = 6; HR, n = 27; BF, n = 3). Acute CBD dosing had no effect on BP or HR under control conditions. Similarly, chronic dosing with CBD had no effect on HR. In models of stress, acute CBD administration significantly reduced the increase in BP and HR induced by stress (BP, mean difference (MD) −3.54, 95% CI −5.19, −1.9, p < 0.0001; HR, MD −16.23, 95% CI −26.44, −6.02, p = 0.002). In mouse models of stroke, CBD significantly increased cerebral blood flow (CBF, standardized mean difference (SMD) 1.62, 95% CI 0.41, 2.83, p = 0.009). Heterogeneity among the studies was present, there was no publication bias except in HR of control and stressful conditions after acute CBD dosing, and median study quality was 5 out of 9 (ranging from 1 to 8). From the limited data available, we conclude that acute and chronic administration of CBD had no effect on BP or HR under control conditions, but reduces BP and HR in stressful conditions, and increases cerebral blood flow (CBF) in mouse models of stroke. Further studies are required to fully understand the potential haemodynamic effects of CBD in humans under normal and pathological conditions. PMID

  5. A comparison of head motion and prefrontal haemodynamics during upright and recumbent cycling exercise.

    PubMed

    Tempest, Gavin D; Eston, Roger G; Parfitt, Gaynor

    2017-11-01

    The aim of this observational study was to compare head motion and prefrontal haemodynamics during exercise using three commercial cycling ergometers. Participants (n = 12) completed an incremental exercise test to exhaustion during upright, recumbent and semi-recumbent cycling. Head motion (using accelerometry), physiological data (oxygen uptake, end-tidal carbon dioxide [P ET CO 2 ] and heart rate) and changes in prefrontal haemodynamics (oxygenation, deoxygenation and blood volume using near infrared spectroscopy [NIRS]) were recorded. Despite no difference in oxygen uptake and heart rate, head motion was higher and P ET CO 2 was lower during upright cycling at maximal exercise (P<0·05). Analyses of covariance (covariates: head motion P>0·05; P ET CO 2 , P<0·01) revealed that prefrontal oxygenation was higher during semi-recumbent than recumbent cycling and deoxygenation and blood volume were higher during upright than recumbent and semi-recumbent cycling (respectively; P<0·05). This work highlights the robustness of the utility of NIRS to head motion and describes the potential postural effects upon the prefrontal haemodynamic response during upright and recumbent cycling exercise. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  6. Influence of continuous haemofiltration-related hypothermia on haemodynamic variables and gas exchange in septic patients.

    PubMed

    Matamis, D; Tsagourias, M; Koletsos, K; Riggos, D; Mavromatidis, K; Sombolos, K; Bursztein, S

    1994-07-01

    To investigate the influence of continuous haemofiltration (CHF) on haemodynamics, gas exchange and core temperature in critically ill septic patients with acute renal failure. In 20 patients (17 male, 3 female) ultrafiltration rate, core temperature, gas exchange and haemodynamic variables were measured at regular intervals during the first 48 h of haemofiltration. Baseline data were compared to those obtained 30 min after initiating CHF and also to those during hypothermia (if observed). Haemodynamic variables remained remarkably constant throughout the study period. In patients with a relatively low ultrafiltration rate (855 +/- 278 ml/h) temperature did not change, while in patients with a high ultrafiltration rate (1468 +/- 293 ml/h) core temperature significantly decreased from 37.6 +/- 0.9 degrees C to 34.8 +/- 0.8 degrees C (p < 0.001). There was a statistically significant correlation between temperature decrease and ultrafiltration rate (r = -0.68, Y = 1.8-0.003 X, p < 0.01). Hypothermic patients also showed a mean decrease in VO2 from 141 +/- 22 ml/min/m2 to 112 +/- 22 ml/min/m2 (p < 0.01) with a concomitant increase in PaO2 from 103 +/- 37 mmHg to 140 +/- 42 mmHg (p < 0.001) and in PvO2 from 35 +/- 4 mmHg to 41 +/- 5 mmHg (p < 0.001). 1) Continuous haemofiltration does not cause significant alternations in haemodynamic variables. 2) Hypothermia frequently occurs in patients undergoing continuous haemofiltration with high ultrafiltration rates. These hypothermic patients show a reduction in VO2 leading to an increase in PvO2 and PaO2. This mild hypothermia in these circumstances has no evident deleterious effects.

  7. Impact of organic polyelectrolytes on coagulation of source-separated black water.

    PubMed

    Kozminykh, Pavlo; Heistad, Arve; Ratnaweera, Harsha C; Todt, Daniel

    2016-01-01

    Household wastewater is originated from common people's activities and has a potential harmful impact on the environment if discharged directly without proper treatment. Toilet wastewater or black water (BW) contains urine, faeces, toilet paper and flushing water and it contains the majority of pollutants obtained from a single household. In this study, the focus was on BW treatment using chemical methods. The main goal of current research was to define the possibility and applicability of conventional coagulants and flocculants in direct chemical treatment of vacuum-collected BW to remove particles, organic matter and phosphorous. After the definition of dosing ranges, based on the equivalent doses in conventional municipal and industrial wastewater treatment data, aluminium and iron coagulants, organic polyelectrolytes (polymers with anionic, neutral and cationic charge with different molecular weights) and their various combinations were tested using the well-known jar-test laboratory method to study aggregation and solid-liquid separation processes in raw BW. The most important process parameter during the coagulation was pH level, dependent on the type and doses of metal salts. Some side processes were found to occur while using iron-based coagulants. Dosing of either single coagulants or single polymers did not give satisfactory results, while a combination of aluminium salts and cationic polymers showed high removal rates in total suspended solids, total chemical oxygen demand and ortho-phosphates, reaching 97.8%, 92% and 98.6%, respectively, with the optimal doses of chemicals. Cationic polymers with the lowest molecular weight and highest charge density were the most efficient in combination with aluminium coagulants.

  8. Coagulation/flocculation process with polyaluminum chloride for the remediation of oil sands process-affected water: Performance and mechanism study.

    PubMed

    Wang, Chengjin; Alpatova, Alla; McPhedran, Kerry N; Gamal El-Din, Mohamed

    2015-09-01

    This study investigated the application of polyaluminum chloride (PACl) for the treatment of the oil sands process-affected water (OSPW). These coagulants are commonly used in water treatment with the most effective species reported to be Al13. PACl with 83.6% Al13 was synthesized using the slow base titration method and compared with a commercially available PACl in terms of aluminum species distribution, coagulation/flocculation (CF) performance, floc morphology, and contaminant removal. Both coagulants were effective in removing suspended solids, achieving over 96% turbidity removal at all applied coagulant doses (0.5-3.0 mM Al). The removal efficiencies of metals varied among different metals depending on their pKa values with metal cations having pKa values (Fe, Al, Ga, and Ti) below OSPW pH of 6.9-8.1 (dose dependent) being removed by more than 90%, while cations with higher pKa values (K, Na, Ca, Mg and Ni) had removals of less than 40%. Naphthenic acids were not removed due to their low molecular weights, negative charges, and hydrophilic characteristics at the OSPW pH. At the highest applied coagulant dose of 3.0 mM Al, the synthetic PACl reduced Vibrio fischeri inhibition effect to 43.3 ± 3.0% from 49.5 ± 0.4% in raw OSPW. In contrast, no reduction of toxicity was found for OSPW treated with the commercial PACl. Based on water quality and floc analyses, the dominant CF mechanism for particle removal during OSPW treatment was considered to be enmeshment in the precipitates (i.e., sweep flocculation). Overall, the CF using synthesized PACl can be a valuable pretreatment process for OSPW to create wastewater that is more easily treated by downstream processes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Epsilon aminocaproic acid reduces blood transfusion and improves the coagulation test after pediatric open-heart surgery: a meta-analysis of 5 clinical trials.

    PubMed

    Lu, Jun; Meng, Haoyu; Meng, Zhaoyi; Sun, Ying; Pribis, John P; Zhu, Chunyan; Li, Quan

    2015-01-01

    Excessive postoperative blood loss after cardiopulmonary bypass is a common problem, especially in patients suffering from congenital heart diseases. The efficacy of epsilon aminocaproic acid (EACA) as a prophylactic treatment for postoperative bleeding after pediatric open-heart surgery has not been determined. This meta-analysis investigates the efficacy of EACA in the minimization of bleeding and blood transfusion and the maintenance of coagulation tests after pediatric open-heart surgery. A comprehensive literature search was performed to identify all randomized clinical trials on the subject. PubMed, Embase, the Cochrane Library, and the Chinese Medical Journal Network were screened. The primary outcome used for the analysis was postoperative blood loss. Secondary outcomes included postoperative blood transfusion, re-exploration rate and postoperative coagulation tests. The mean difference (MD) and risk ratio (RR) with 95% confidence intervals (CI) were used as summary statistics. Five trials were included in this meta-analysis of 515 patients. Prophylactic EACA was associated with a reduction in postoperative blood loss, but this difference did not reach statistical significance (MD: -7.08; 95% CI: -16.11 to 1.95; P = 0.12). Patients treated with EACA received fewer postoperative blood transfusions, including packed red blood cells (MD: -8.36; 95% CI: -12.63 to -4.09; P = 0.0001), fresh frozen plasma (MD: -3.85; 95% CI: -5.63 to -2.08; P < 0.0001), and platelet concentrate (MD: -10.66; 95% CI: -18.45 to -2.87; P = 0.007), and had a lower re-exploration rate (RR: 0.46; 95% CI: 0.23 to 0.92; P = 0.03). Prophylactic EACA also improved coagulation tests 6 hours after open-heart surgery. Prophylactic EACA minimizes postoperative blood transfusion and helps maintain coagulation in pediatric patients undergoing open-heart surgery. Therefore, the results of this study indicate that adjunctive EACA is a good choice for the prevention of postoperative blood transfusion

  10. Epsilon aminocaproic acid reduces blood transfusion and improves the coagulation test after pediatric open-heart surgery: a meta-analysis of 5 clinical trials

    PubMed Central

    Lu, Jun; Meng, Haoyu; Meng, Zhaoyi; Sun, Ying; Pribis, John P; Zhu, Chunyan; Li, Quan

    2015-01-01

    Background: Excessive postoperative blood loss after cardiopulmonary bypass is a common problem, especially in patients suffering from congenital heart diseases. The efficacy of epsilon aminocaproic acid (EACA) as a prophylactic treatment for postoperative bleeding after pediatric open-heart surgery has not been determined. This meta-analysis investigates the efficacy of EACA in the minimization of bleeding and blood transfusion and the maintenance of coagulation tests after pediatric open-heart surgery. Methods: A comprehensive literature search was performed to identify all randomized clinical trials on the subject. PubMed, Embase, the Cochrane Library, and the Chinese Medical Journal Network were screened. The primary outcome used for the analysis was postoperative blood loss. Secondary outcomes included postoperative blood transfusion, re-exploration rate and postoperative coagulation tests. The mean difference (MD) and risk ratio (RR) with 95% confidence intervals (CI) were used as summary statistics. Results: Five trials were included in this meta-analysis of 515 patients. Prophylactic EACA was associated with a reduction in postoperative blood loss, but this difference did not reach statistical significance (MD: -7.08; 95% CI: -16.11 to 1.95; P = 0.12). Patients treated with EACA received fewer postoperative blood transfusions, including packed red blood cells (MD: -8.36; 95% CI: -12.63 to -4.09; P = 0.0001), fresh frozen plasma (MD: -3.85; 95% CI: -5.63 to -2.08; P < 0.0001), and platelet concentrate (MD: -10.66; 95% CI: -18.45 to -2.87; P = 0.007), and had a lower re-exploration rate (RR: 0.46; 95% CI: 0.23 to 0.92; P = 0.03). Prophylactic EACA also improved coagulation tests 6 hours after open-heart surgery. Conclusions: Prophylactic EACA minimizes postoperative blood transfusion and helps maintain coagulation in pediatric patients undergoing open-heart surgery. Therefore, the results of this study indicate that adjunctive EACA is a good choice for the

  11. Removal of disinfection by-product precursors by coagulation and an innovative suspended ion exchange process.

    PubMed

    Metcalfe, David; Rockey, Chris; Jefferson, Bruce; Judd, Simon; Jarvis, Peter

    2015-12-15

    This investigation aimed to compare the disinfection by-product formation potentials (DBPFPs) of three UK surface waters (1 upland reservoir and 2 lowland rivers) with differing characteristics treated by (a) a full scale conventional process and (b) pilot scale processes using a novel suspended ion exchange (SIX) process and inline coagulation (ILCA) followed by ceramic membrane filtration (CMF). Liquid chromatography-organic carbon detection analysis highlighted clear differences between the organic fractions removed by coagulation and suspended ion exchange. Pretreatments which combined SIX and coagulation resulted in significant reductions in dissolved organic carbon (DOC), UV absorbance (UVA), trihalomethane and haloacetic acid formation potential (THMFP, HAAFP), in comparison with the SIX or coagulation process alone. Further experiments showed that in addition to greater overall DOC removal, the processes also reduced the concentration of brominated DBPs and selectively removed organic compounds with high DBPFP. The SIX/ILCA/CMF process resulted in additional removals of DOC, UVA, THMFP, HAAFP and brominated DBPs of 50, 62, 62, 62% and 47% respectively compared with conventional treatment. Copyright © 2015. Published by Elsevier Ltd.

  12. Buffer capacity of 4% succinylated gelatin does not provide any advantages over acidic 6% hydroxyethyl starch 130/0.4 for acid-base balance during experimental mixed acidaemia in a porcine model.

    PubMed

    Esche, V; Russ, M; Melzer, S; Grossmann, B; Boemke, W; Unger, J K

    2008-11-01

    Four percent gelatine is an alkaline compound due to NH2 groups, whereas 6% hydroxyethyl starch 130/0.4 (HES130) has acidic features. We investigated whether these solutions lead to differences in acid-base balance in pigs during acidaemia and correction of pH. Anaesthetized pigs were randomized to HES130 or gelatine infusion (n = 5 per group). Animals received acid infusion (0.4 M solution of lactic acid and HCl diluted in normal saline) and low tidal volume ventilation (6-7 mL kg(-1), PaCO2 of 80-85 mmHg, pH 7.19-7.24). Measurements were made before and after induction of acidaemia, before and after correction of pH with haemofiltration (continuous venovenous haemofiltration) and tris-hydroxymethylaminomethane infusion. We measured parameters describing acid-base balance according to Stewart's approach, ketone body formation, oxygen delivery, haemodynamics, diuresis and urinary pH. Acid-base balance did not differ significantly between the groups. In HES130-treated pigs, the haemodilution-based drop of haemoglobin (1.4 +/- 1.0 g dL(-1), median +/- SD) was paralleled by an increase in the cardiac output (0.5 +/- 0.4 L min(-1). Lacking increases in cardiac output, gelatine-treated pigs demonstrated a reduction in oxygen delivery (149.4 +/- 106.0 mL min(-1)). Tris-hydroxymethylaminomethane volumes required for pH titration to desired values were significantly higher in the gelatine group (0.7 +/- 0.1 mL kg(-1) h(-1) vs. HES130: 0.5 +/- 0.2 mL kg(-1) h(-1)). The buffer capacity of gelatine did not lead to favourable differences in acid-base balance in comparison to HES130.

  13. Exact combinatorial approach to finite coagulating systems

    NASA Astrophysics Data System (ADS)

    Fronczak, Agata; Chmiel, Anna; Fronczak, Piotr

    2018-02-01

    This paper outlines an exact combinatorial approach to finite coagulating systems. In this approach, cluster sizes and time are discrete and the binary aggregation alone governs the time evolution of the systems. By considering the growth histories of all possible clusters, an exact expression is derived for the probability of a coagulating system with an arbitrary kernel being found in a given cluster configuration when monodisperse initial conditions are applied. Then this probability is used to calculate the time-dependent distribution for the number of clusters of a given size, the average number of such clusters, and that average's standard deviation. The correctness of our general expressions is proved based on the (analytical and numerical) results obtained for systems with the constant kernel. In addition, the results obtained are compared with the results arising from the solutions to the mean-field Smoluchowski coagulation equation, indicating its weak points. The paper closes with a brief discussion on the extensibility to other systems of the approach presented herein, emphasizing the issue of arbitrary initial conditions.

  14. Analysis and optimization of coagulation and flocculation process

    NASA Astrophysics Data System (ADS)

    Saritha, V.; Srinivas, N.; Srikanth Vuppala, N. V.

    2017-03-01

    Natural coagulants have been the focus of research of many investigators through the last decade owing to the problems caused by the chemical coagulants. Optimization of process parameters is vital for the effectiveness of coagulation process. In the present study optimization of parameters like pH, dose of coagulant and mixing speed were studied using natural coagulants sago and chitin in comparison with alum. Jar test apparatus was used to perform the coagulation. The results showed that the removal of turbidity was up to 99 % by both alum and chitin at lower doses of coagulant, i.e., 0.1-0.3 g/L, whereas sago has shown a reduction of 70-100 % at doses of 0.1 and 0.2 g/L. The optimum conditions observed for sago were 6 and 7 whereas chitin was stable at all pH ranges, lower coagulant doses, i.e., 0.1-0.3 g/L and mixing speed—rapid mixing at 100 rpm for 10 min and slow mixing 20 rpm for 20 min. Hence, it can be concluded that sago and chitin can be used for treating water even with large seasonal variation in turbidity.

  15. Comparison of coagulation pretreatment of produced water from natural gas well by polyaluminium chloride and polyferric sulphate coagulants.

    PubMed

    Zhai, Jun; Huang, Zejin; Rahaman, Md Hasibur; Li, Yue; Mei, Longyue; Ma, Hongpu; Hu, Xuebin; Xiao, Haiwen; Luo, Zhiyong; Wang, Kunping

    2017-05-01

    This study aimed to optimise coagulation pretreatment of the produced water (PW) collected from a natural gas field. Two coagulants, polyferric sulphate (PFS) and polyaluminium chloride (PACl), were applied separately for the organics, suspended solids (SS), and colour removal. Treatment performance at different coagulant dosages, initial pH values, stirring patterns, and the addition of cationic polyacrylamide (PAM) was investigated in jar tests. The optimal coagulation conditions were dosage of PACl 25 g/L or PFS 20 g/L with that of PAM 30 mg/L, initial pH of 11, and fast mixing of 1.5 min (for PACl) or 2 min (for PFS) at 250 rpm followed by slow mixing of 15 min at 50 rpm for both coagulants. PACl performed better than PFS to remove chemical oxygen demand (COD), total organic carbon (TOC), SS, and colour, and achieved a removal efficiency of 90.1%, 89.4%, 99.0%, and 99.9%, respectively, under the optimal condition; while PFS efficiency was 86.1%, 86.1%, 99.0%, and 98.2%, respectively. However, oil removal was higher in PFS coagulation compared to PACl and showed 98.9% and 95.3%, respectively. Biodegradability, ratio of the biological oxygen demand (five-day) (BOD 5 )/COD, of the PW after pretreatment increased from 0.08 to 0.32 for PFS and 0.43 for PACl. Zeta potential (Z-potential) analysis at the optimum coagulant dosage of PACl and PFS suggests that charge neutralisation was the predominant mechanism during coagulation. Better efficiency was observed at higher pH. The addition of PAM and starring pattern had a minor influence on the removal performance of both coagulants. The results suggest that PACl or PFS can be applied for the pretreatment of PW, which can provide substantial removal of carbon, oil, and colour, a necessary first step for subsequent main treatment units such as chemical oxidation or biological treatment.

  16. Magnetic Resonance Mediated Radio Frequency Coagulation for Vascular Repair

    NASA Astrophysics Data System (ADS)

    Zhao, Ming

    Purpose. Magnetic Resonance Mediated Radiofrequency Coagulation employs the RF heating effect of MRI scanning to coagulate biomaterials for repair of vascular defects. Coagulation of a protein biomaterial by MR-induced RF heating is a novel means to effect repair of defects such as aneurysms or arteriovenous malformations. Our novel method is to coagulate a thermosetting material (such as egg white, which can be used for investigating heat coagulation behavior and MR relaxation properties) delivered endovascularly by catheter and coagulated by RF-induced heating of an intracatheter resonant wire antenna in the scanner. Methods. Experiments were performed on a Siemens 1.5 T MRI scanner and a Bruker 14T NMR spectrometer. Egg white was brought to equilibrium at seven temperatures (20, 30, 40, 50, 60, 70 and 37 °C) in sequence. Measurement of the water spin-lattice relaxation time Ti, spin-spin relaxation time T2, spin-lattice relaxation time in the rotating frame T1p, or full width at half maximum of the MT spectrum were performed at each temperature. Relaxation parameters of raw egg white and egg white after coagulation at 70 °C were measured in the scanner at 20 °C to determine optimum inversion time, echo time and offset frequency for good image contrast between coagulated and uncoagulated protein. Finally, coagulation of egg white within a glass aneurysm phantom by RF heating in the scanner was performed to demonstrate the MR coagulation methodology and the ability to achieve image contrast between coagulated and uncoagulated biomaterial. Results. Water T2, T1p and MT gave the most definitive indication of the change from uncoagulated at low temperature to fully coagulated at 60 °C, while water T1 showed only the expected gradual increase with temperature, and no response to coagulation. MT weighted imaging is expected to be the optimum method to establish the coagulation condition of the biomaterial.

  17. In Vitro Assessment of Nanoparticle Effects on Blood Coagulation.

    PubMed

    Potter, Timothy M; Rodriguez, Jamie C; Neun, Barry W; Ilinskaya, Anna N; Cedrone, Edward; Dobrovolskaia, Marina A

    2018-01-01

    Blood clotting is a complex process which involves both cellular and biochemical components. The key cellular players in the blood clotting process are thrombocytes or platelets. Other cells, including leukocytes and endothelial cells, contribute to clotting by expressing the so-called pro-coagulant activity (PCA) complex on their surface. The biochemical component of blood clotting is represented by the plasma coagulation cascade, which includes plasma proteins also known as coagulation factors. The coordinated interaction between platelets, leukocytes, endothelial cells, and plasma coagulation factors is necessary for maintaining hemostasis and for preventing excessive bleeding. Undesirable activation of all or some of these components may lead to pathological blood coagulation and life-threatening conditions such as consumptive coagulopathy or disseminated intravascular coagulation (DIC). In contrast, unintended inhibition of the coagulation pathways may lead to hemorrhage. Thrombogenicity is the property of a test material to induce blood coagulation by affecting one or more elements of the clotting process. Anticoagulant activity refers to the property of a test material to inhibit coagulation. The tendency to cause platelet aggregation, perturb plasma coagulation, and induce leukocyte PCA can serve as an in vitro measure of a nanomaterial's likelihood to be pro- or anticoagulant in vivo. This chapter describes three procedures for in vitro analyses of platelet aggregation, plasma coagulation time, and activation of leukocyte PCA. Platelet aggregation and plasma coagulation procedures have been described earlier. The revision here includes updated details about nanoparticle sample preparation, selection of nanoparticle concentration for the in vitro study, and updated details about assay controls. The chapter is expanded to describe a method for the leukocyte PCA analysis and case studies demonstrating the performance of these in vitro assays.

  18. Pilot testing of dissolved air flotation (DAF) in a highly effective coagulation-flocculation integrated (FRD) system.

    PubMed

    Wang, Yili; Guo, Jinlong; Tang, Hongxiao

    2002-01-01

    Factors of pretreatment coagulation/flocculation units were studied using raw water of low temperature and low turbidity. Aluminum sulfate (AS) and selected polyaluminium chlorides (PACls) were all effective in the DAF process when used under favorable conditions of coagulant addition, coagulation, flocculation and flotation units. Compared with the AS coagulant, PACls, at lower dosage, could give the same effective performance even with shorter coagulation/flocculation time or lower recycle ratio during the treatment of cold water. This is attributed to the higher-charged polymeric Al species, and the lower hydrophilic and more compact flocculated flocs of PACl coagulant. Based on results of pilot experiments, the goal of FRD system can be achieved by combining a DAF heterocoagulation reactor with PACl coagulant (F), an efficient flocculation reactor (R), as well as an economical auto-dosing system (D).

  19. Thymoquinone Modulates Blood Coagulation in Vitro via Its Effects on Inflammatory and Coagulation Pathways

    PubMed Central

    Muralidharan-Chari, Vandhana; Kim, Jaehan; Abuawad, Ahlam; Naeem, Mubeena; Cui, Huadong; Mousa, Shaker A.

    2016-01-01

    Thymoquinone (THQ) is a major component of black seeds. Given that both THQ and black seeds exhibit anti-cancer and anti-inflammatory activities, we hypothesized that THQ will affect cancer-associated thrombosis (CAT), which is primarily triggered by tissue factor (TF) and inflammation. The effect of both black seed-extracted and purchased (“pure”) THQ on normal blood coagulation was tested with in vitro thromboelastography (TEG) and activated partial thromboplastin time (aPTT) coagulation assays. The effect of pure THQ on CAT was tested with aPTT assay using pancreatic cancer cell lines that are either positive or negative for TF, and with TEG assay using lipopolysaccharide as an inflammatory trigger. Additionally, the direct effect of THQ on the inactivation of factors IIa and Xa was assessed. Since TNF-α facilitates crosstalk between inflammation and thrombosis by triggering the NF-κB pathway, we tested THQ’s ability to interfere with this communication with a luciferase assay. Both extracted and pure THQ had minimal effects on normal blood coagulation. Pure THQ reversed CAT initiated by both TF and inflammation to basal levels (p < 0.001). Mechanistically, while THQ had minimal to no effect on factor IIa and Xa inactivation, it strongly reduced the effects of TNF-α on NF-κB elements (p < 0.001). THQ has a minimal effect on basal coagulation and can reverse CAT in vitro, possibly by interfering with the crosstalk between inflammation and coagulation. This study suggests the utility of THQ as a preventative anticoagulant and/or as a supplement to existing chemotherapies and anticoagulant therapies. PMID:27043539

  20. Dust Coagulation in Protoplanetary Accretion Disks

    NASA Technical Reports Server (NTRS)

    Schmitt, W.; Henning, Th.; Mucha, R.

    1996-01-01

    The time evolution of dust particles in circumstellar disk-like structures around protostars and young stellar objects is discussed. In particular, we consider the coagulation of grains due to collisional aggregation. The coagulation of the particles is calculated by solving numerically the non-linear Smoluchowski equation. The different physical processes leading to relative velocities between the grains are investigated. The relative velocities may be induced by Brownian motion, turbulence and drift motion. Starting from different regimes which can be identified during the grain growth we also discuss the evolution of dust opacities. These opacities are important for both the derivation of the circumstellar dust mass from submillimeter/millimeter continuum observations and the dynamical behavior of the disks. We present results of our numerical studies of the coagulation of dust grains in a turbulent protoplanetary accretion disk described by a time-dependent one-dimensional (radial) alpha-model. For several periods and disk radii, mass distributions of coagulated grains have been calculated. From these mass spectra, we determined the corresponding Rosseland mean dust opacities. The influence of grain opacity changes due to dust coagulation on the dynamical evolution of a protostellar disk is considered. Significant changes in the thermal structure of the protoplanetary nebula are observed. A 'gap' in the accretion disk forms at the very frontier of the coagulation, i.e., behind the sublimation boundary in the region between 1 and 5 AU.

  1. Removal of Arsenic from Drinking Water by Adsorption and Coagulation

    NASA Astrophysics Data System (ADS)

    Zhang, M.; Sugita, H.; Hara, J.; Takahashi, S.

    2013-12-01

    Removal of arsenic from drinking water has been an important issue worldwide, which has attracted greater attentions in recent years especially for supplying safe drinking water in developing countries. Although many kinds of treatment approaches that are available or applicable both in principle and practice, such as adsorption, coagulation, membrane filtration, ion exchange, biological process, electrocoagulation and so on, the first 2 approaches (i.e., adsorption and coagulation) are most promising due to the low-cost, high-efficiency, simplicity of treating systems, and thus can be practically used in developing countries. In this study, a literature survey on water quality in Bangladesh was performed to understand the ranges of arsenic concentration and pH of groundwater in Bangladesh. A series of tests were then organized and performed to investigate the effects of arsenic concentration, arsenic forms, pH, chemical compositions of the materials used for adsorption and coagulation, particle size distribution and treatment time on quality of treated water. The experimental results obtained in the study illustrated that both adsorption and coagulation can be used to effectively reduce the concentrations of either arsenic (V) or arsenic (III) from the contaminated water. Coagulation of arsenic with a magnesium-based material developed in this study can be very effective to remove arsenic, especially arsenic (V), from contaminated water with a concentration of 10 ppm to an undetectable level of 0.002 ppm by ICP analyses. Compared to arsenic (III), arsenic (V) is easier to be removed. The materials used for adsorption and coagulation in this study can remove arsenic (V) up to 9 mg/g and 6 mg/g, and arsenic (III) up to 4 mg/g and 3 mg/g, respectively, depending on test conditions and compositions of the materials being used. The control of pH during treatment can be a challenging technical issue for developing both adsorbent and coagulant. Keywords: Water Treatment

  2. Characterization and removal of natural organic matter from slow sand filter effluent followed by alum coagulation

    NASA Astrophysics Data System (ADS)

    Hidayah, Euis Nurul; Chou, Yung-Chen; Yeh, Hsuan-Hsien

    2018-03-01

    Characterization and removal of natural organic matter, which is contained in the effluent of slow sand filters, was observed by alum coagulation under various dosages. In addition to non-purgedable dissolved organic carbon (NPDOC), trihalomethanes formation potential (THMFP) and haloacetic acid formation potential (HAAFP) measurement, high-performance size-exclusion chromatography (HPSEC) with ultraviolet/visible and dissolved organic carbon (DOC) detectors was used to characterize the various organic fractions contained in the water before and after coagulation. The results show that alum coagulation could effectively remove hydrophobic aromatic, which forms mainly humic substances. The reduction in THMFP was found to be higher than that of NPDOC and HAAFP under specific alum dosage, and the former was also found to be proportional to the corresponding reduction in the area of hydrophobic aromatic fraction, mostly humic subtances, as obtained from HPSEC chromatogram with peak-fitting.

  3. The effectiveness of coagulation for water reclamation from a wastewater treatment plant that has a long hydraulic and sludge retention times: A case study.

    PubMed

    Cui, Xiaochun; Zhou, Dandan; Fan, Wei; Huo, Mingxin; Crittenden, John C; Yu, Zhisen; Ju, Pengfei; Wang, Yang

    2016-08-01

    Coagulation is a feasible process to reclaim municipal wastewater, however, the role of coagulation in removing effluent organic matter (EfOM) from underutilized wastewater treatment plants (WWTPs) has not been fully explored. We identified the characteristics of the EfOM from a typical underutilized WWTP (i.e., the ratio of actual capacity to design capacity is 50%-70%), and investigated the performance of coagulation on suspended solids (SS) and dissolved organic matter (DOM) removal. The effluent could even satisfy the highest national standard of China (Class 1 A) for WWTP effluent, as evaluated by the traditional parameters such as SS and chemical oxygen demand (COD). However, the DOM in the EfOM we studied contained considerable biomass-associated products (BAPs), which were dominated by proteins with a molecular weight of approximately 150 kDa. In addition, protein also dominated the DOM after coagulation. Fulvic acid and humic-like acid organics were poorly removed by either AlCl3 or polyaluminum chloride (PAC) coagulation, even with a dosage as high as 24 mg Al L(-1). Biodegradability was very poor, as the ratio of biological oxygen demand (BOD5) to COD was less than 0.17. After coagulation the typical BAPs, protein and polysaccharide, remained as high as 1.6 mg L(-1) and 1.2 mg L(-1) respectively. In this study we found coagulation was ineffective for removal of recalcitrant BAPs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Coagulation disorders in dogs with hepatic disease.

    PubMed

    Prins, M; Schellens, C J M M; van Leeuwen, M W; Rothuizen, J; Teske, E

    2010-08-01

    Liver disease has been associated with abnormalities in haemostasis. In this study, coagulation times, platelet counts, platelet activity parameters, activities of individual coagulation factors, D-dimers, antithrombin (AT) and protein C activity were measured in 42 dogs with histologically confirmed liver disease. Outcome was correlated with histological diagnosis. One or more coagulation abnormalities were present in 57% of dogs with hepatic disease. Activated partial thromboplastin time was significantly prolonged in dogs with chronic hepatitis (CH), with or without cirrhosis. Mean platelet numbers, AT and factor IX activity were significantly lower in dogs with CH plus cirrhosis, compared to dogs with other hepatopathies. D-dimers were not significantly increased in any group. Only three dogs, all with different histological diagnoses, satisfied the criteria for disseminated intravascular coagulation (DIC). Haemostatic abnormalities were primarily seen in dogs with cirrhosis and this may be due to reduced synthesis rather than increased consumption of coagulation factors. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  5. The predictive value of haemodynamic parameters for outcome of deep venous reconstructions in patients with chronic deep vein obstruction - A systematic review.

    PubMed

    Kurstjens, Rlm; de Wolf, Maf; Kleijnen, J; de Graaf, R; Wittens, Cha

    2017-09-01

    Objective The aim of this study was to investigate the predictive value of haemodynamic parameters on success of stenting or bypass surgery in patients with non-thrombotic or post-thrombotic deep venous obstruction. Methods EMBASE, MEDLINE and trial registries were searched up to 5 February 2016. Studies needed to investigate stenting or bypass surgery in patients with post-thrombotic obstruction or stenting for non-thrombotic iliac vein compression. Haemodynamic data needed to be available with prognostic analysis for success of treatment. Two authors, independently, selected studies and extracted data with risk bias assessment using the Quality in Prognosis Studies tool. Results Two studies using stenting and two using bypass surgery were included. Three investigated plethysmography, though results varied and confounding was not properly taken into account. Dorsal foot vein pressure and venous refill times appeared to be of influence in one study, though confounding by deep vein incompetence was likely. Another investigated femoral-central pressure gradients without finding statistical significance, though sample size was small without details on statistical methodology. Reduced femoral inflow was found to be a predictor for stent stenosis or occlusion in one study, though patients also received additional surgery to improve stent inflow. Data on prediction of haemodynamic parameters for stenting of non-thrombotic iliac vein compression were not available. Conclusions Data on the predictive value of haemodynamic parameters for success of treatment in deep venous obstructive disease are scant and of poor quality. Plethysmography does not seem to be of value in predicting outcome of stenting or bypass surgery in post-thrombotic disease. The relevance of pressure-related parameters is unclear. Reduced flow into the common femoral vein seems to be predictive for in-stent stenosis or occlusion. Further research into the predictive effect of haemodynamic parameters is

  6. Study on Coagulant Dosing Control System of Micro Vortex Water Treatment

    NASA Astrophysics Data System (ADS)

    Fengping, Hu; Qi, Fan; Wenjie, Hu; Xizhen, He; Hongling, Dai

    2018-03-01

    In view of the characteristics of nonlinearity, large time delay and multi disturbance in the process of coagulant dosing in water treatment, it is difficult to control the dosage of coagulant. According to the four indexes of raw water quality parameters (raw water flow, turbidity, pH value) and turbidity of sedimentation tank, the micro vortex coagulation dosing control model is constructed based on BP neural network and GA. The forecast results of BP neural network model are ideal, and after the optimization of GA, the prediction accuracy of the model is partly improved. The prediction error of the optimized network is ±0.5 mg/L, and has a better performance than non-optimized network.

  7. Patient-specific CFD simulation of intraventricular haemodynamics based on 3D ultrasound imaging.

    PubMed

    Bavo, A M; Pouch, A M; Degroote, J; Vierendeels, J; Gorman, J H; Gorman, R C; Segers, P

    2016-09-09

    The goal of this paper is to present a computational fluid dynamic (CFD) model with moving boundaries to study the intraventricular flows in a patient-specific framework. Starting from the segmentation of real-time transesophageal echocardiographic images, a CFD model including the complete left ventricle and the moving 3D mitral valve was realized. Their motion, known as a function of time from the segmented ultrasound images, was imposed as a boundary condition in an Arbitrary Lagrangian-Eulerian framework. The model allowed for a realistic description of the displacement of the structures of interest and for an effective analysis of the intraventricular flows throughout the cardiac cycle. The model provides detailed intraventricular flow features, and highlights the importance of the 3D valve apparatus for the vortex dynamics and apical flow. The proposed method could describe the haemodynamics of the left ventricle during the cardiac cycle. The methodology might therefore be of particular importance in patient treatment planning to assess the impact of mitral valve treatment on intraventricular flow dynamics.

  8. Reproducibility of haemodynamical simulations in a subject-specific stented aneurysm model--a report on the Virtual Intracranial Stenting Challenge 2007.

    PubMed

    Radaelli, A G; Augsburger, L; Cebral, J R; Ohta, M; Rüfenacht, D A; Balossino, R; Benndorf, G; Hose, D R; Marzo, A; Metcalfe, R; Mortier, P; Mut, F; Reymond, P; Socci, L; Verhegghe, B; Frangi, A F

    2008-07-19

    This paper presents the results of the Virtual Intracranial Stenting Challenge (VISC) 2007, an international initiative whose aim was to establish the reproducibility of state-of-the-art haemodynamical simulation techniques in subject-specific stented models of intracranial aneurysms (IAs). IAs are pathological dilatations of the cerebral artery walls, which are associated with high mortality and morbidity rates due to subarachnoid haemorrhage following rupture. The deployment of a stent as flow diverter has recently been indicated as a promising treatment option, which has the potential to protect the aneurysm by reducing the action of haemodynamical forces and facilitating aneurysm thrombosis. The direct assessment of changes in aneurysm haemodynamics after stent deployment is hampered by limitations in existing imaging techniques and currently requires resorting to numerical simulations. Numerical simulations also have the potential to assist in the personalized selection of an optimal stent design prior to intervention. However, from the current literature it is difficult to assess the level of technological advancement and the reproducibility of haemodynamical predictions in stented patient-specific models. The VISC 2007 initiative engaged in the development of a multicentre-controlled benchmark to analyse differences induced by diverse grid generation and computational fluid dynamics (CFD) technologies. The challenge also represented an opportunity to provide a survey of available technologies currently adopted by international teams from both academic and industrial institutions for constructing computational models of stented aneurysms. The results demonstrate the ability of current strategies in consistently quantifying the performance of three commercial intracranial stents, and contribute to reinforce the confidence in haemodynamical simulation, thus taking a step forward towards the introduction of simulation tools to support diagnostics and

  9. Dexmedetomidine in Attenuation of Haemodynamic Response and Dose Sparing Effect on Opioid and Anaesthetic Agents in Patients undergoing Laparoscopic Cholecystectomy- A Randomized Study

    PubMed Central

    Bhagat, Nandlal; Karim, Habib Md Reazaul; Hajong, Ranendra; Bhattacharyya, Prithwis; Singh, Manorama

    2016-01-01

    Introduction Perioperative procedures are stressful and lead to haemodynamic instability with potentially devastating consequences. Dexmedetomidine is found to have many of the desired characteristics that are required in perioperative period. Aim To evaluate the ability of pre and intraoperative dexmedetomidine to attenuate stress induced haemodynamic responses, quantifying the anaesthetic agents sparing as well as its cost-effectiveness in patients undergoing laparoscopic cholecystectomy. Materials and Methods The present single blind randomized study was conducted with 120 ASA I and II consented patients who underwent laparoscopic cholecystectomy. Patients were randomly divided into 2 groups (i.e., group D and group N). Prior to induction, group D received 1 μg/kg of Dexmedetomidine and group N received Normal saline infusion over 20 minutes. Group D also received maintenance Dexmedetomidine intraoperatively. Bispectral index and minimum alveolar concentration monitoring was done in both the groups. Haemodynamic parameters were noted till 100 minutes post laryngoscopy. Opioid and anaesthetic agent consumptions were also noted and cost analysis was done. Medcalc–Version 12.5.0.0 software was used for statistics and p <0.05 was considered significant. Results Dexmedetomidine attenuated the stress induced haemodynamics responses and produced stable, relatively non fluctuating haemodynamics throughout. The Minimum Alveolar Concentration (MAC) requirement and the consumptions of Fentanyl and Isoflurane were significantly less in the Dexmedetomidine group (p<0.0001). However, despite anaesthetic dose sparing effect the anaesthetic technique was not cost-effective. Conclusion Dexmedetomidine is effective in attenuating haemodynamic responses in laparoscopic surgery and having dose sparing effect on Fentanyl, Propofol and Isoflurane. However, overall this technique is not cost-effective. PMID:28050479

  10. A natural coagulant protein from Moringa oleifera: isolation, characterization, and potential use for water treatment

    NASA Astrophysics Data System (ADS)

    Choudhary, Manisha; Neogi, Sudarsan

    2017-10-01

    In developing countries pond water is still widely used for drinking and household purposes, which develops higher turbidity during rainy seasons and requires a large amount of chemical coagulants, and this leads to high cost of treatment. To mitigate this, it is important to find an economical and natural coagulant to treat turbid water. The present study is focused on using a plant based component as a natural coagulant that is sustainable and environment-friendly. This work focuses on the extraction, isolation and purification of a natural coagulant from seed kernels of Moringa oleifera to enhance its turbidity removal efficiency. The determination of themolecular weight of the purified proteins was done using sodium dodecyl sulfate polyacrylamide gel electrophoresis. The active coagulant proteins were isolated using 30-60% and 60-80% saturation of ammonium sulfate. It was observed that proteins with molecular weight less than 36 kDa have superior coagulation activity. Turbidity removal efficiency of these active coagulant proteins was compared with alum. The possibility of using Moringa oleifera seeds as a natural antimicrobial agent was also investigated.

  11. Blood coagulation status of small-for-dates and postmature infants.

    PubMed Central

    Perlman, M; Dvilansky, A

    1975-01-01

    In a prospective study of blood coagulation status in small-for-dates and postmature infants there was often evidence of intravascular coagulation. Abnormal coagulation findings correlated with the degree of growth retardation and with the degree of postmaturity. Macroscopical placental infarction and neonatal polycythaemia were associated with coagulation abnormalities; asphyxia, however, was not. Intravascular coagulation may be an additional hazard to small-for-dates and postmature infants. PMID:1170815

  12. New lab-made coagulant based on Schinopsis balansae tannin extract: synthesis optimization and preliminary tests on refractory water pollutants

    NASA Astrophysics Data System (ADS)

    Sánchez-Martín, J.; Beltrán-Heredia, J.; Coco-Rivero, B.

    2014-09-01

    Quebracho colorado tannin extract was used as a coagulant raw material for water and wastewater treatment. The chemical synthesis follows a Mannich reaction mechanism and provides a fully working coagulant that can remove several pollutants from water. This paper addresses the optimization of such synthesis and confirms the feasibility of the coagulant by testing it in a preliminary screening for the elimination of dyes and detergents. The optimum combination of reagents was 6.81 g of diethanolamine (DEA) and 2.78 g of formaldehyde (F) per g of tannin extract. So obtained coagulant was succesfully tested on the removal of 9 dyes and 8 detergents.

  13. Point-of-Care Coagulation Monitoring in Trauma Patients.

    PubMed

    Stein, Philipp; Kaserer, Alexander; Spahn, Gabriela H; Spahn, Donat R

    2017-06-01

    Trauma remains one of the major causes of death and disability all over the world. Uncontrolled blood loss and trauma-induced coagulopathy represent preventable causes of trauma-related morbidity and mortality. Treatment may consist of allogeneic blood product transfusion at a fixed ratio or in an individualized goal-directed way based on point-of-care (POC) and routine laboratory measurements. Viscoelastic POC measurement of the developing clot in whole blood and POC platelet function testing allow rapid and tailored coagulation and transfusion treatment based on goal-directed, factor concentrate-based algorithms. The first studies have been published showing that this concept reduces the need for allogeneic blood transfusion and improves outcome. This review highlights the concept of goal-directed POC coagulation management in trauma patients, introduces a selection of POC devices, and presents algorithms which allow a reduction in allogeneic blood product transfusion and an improvement of trauma patient outcome. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. A simple purification and activity assay of the coagulant protein from Moringa oleifera seed.

    PubMed

    Ghebremichael, Kebreab A; Gunaratna, K R; Henriksson, Hongbin; Brumer, Harry; Dalhammar, Gunnel

    2005-06-01

    Use of extracts from Moringa oleifera (MO) is of great interest for low-cost water treatment. This paper discusses water and salt extraction of a coagulant protein from the seed, purification using ion exchange, its chemical characteristics, coagulation and antimicrobial properties. The coagulant from both extracts is a cationic protein with pI greater than 9.6 and molecular mass less than 6.5 kDa. Mass spectrometric analysis of the purified water extract indicated that it contained at least four homologous proteins, based on MS/MS peptide sequence data. The protein is thermoresistant and remained active after 5h heat treatment at 95 degrees C. The coagulant protein showed both flocculating and antibacterial effects of 1.1--4 log reduction. With samples of high turbidity, the MO extract showed similar coagulation activity as alum. Cecropin A and MO extract were found to have similar flocculation effects for clay and microorganisms. Simple methods for both the purification and assay of MO coagulating proteins are presented, which are necessary for large-scale water treatment applications.

  15. Sediment accretion and carbon storage in constructed wetlands receiving water treated with metal-based coagulants

    USGS Publications Warehouse

    Stumpner, Elizabeth; Kraus, Tamara; Liang, Yan; Bachand, Sandra M.; Horwath, William R.; Bachand, Philip A.M.

    2018-01-01

    In many regions of the world, subsidence of organic rich soils threatens levee stability and freshwater supply, and continued oxidative loss of organic matter contributes to greenhouse gas production. To counter subsidence in the Sacramento-San Joaquin Delta of northern California, we examined the feasibility of using constructed wetlands receiving drainage water treated with metal-based coagulants to accrete mineral material along with wetland biomass, while also sequestering carbon in wetland sediment. Nine field-scale wetlands were constructed which received local drainage water that was either untreated (control), or treated with polyaluminum chloride (PAC) or iron sulfate (FeSO4) coagulants. After 23 months of flooding and coagulant treatment, sediment samples were collected near the inlet, middle, and outlet of each wetland to determine vertical accretion rates, bulk density, sediment composition, and carbon sequestration rates. Wetlands treated with PAC had the highest and most spatially consistent vertical accretion rates (~6 cm year-1), while the FeSO4 wetlands had similarly high accretion rates near the inlet but rates similar to the untreated wetland (~1.5 cm year-1) at the middle and outlet sites. The composition of the newly accreted sediment in the PAC and FeSO4 treatments was high in the added metal (aluminum and iron, respectively), but the percent metal by weight was similar to native soils of California. As has been observed in other constructed wetlands, the newly accreted sediment material had lower bulk densities than the native soil material (0.04-0.10 g cm-3 versus 0.2-0.3 g cm-3), suggesting these materials will consolidate over time. Finally, this technology accelerated carbon burial, with rates in PAC treated wetland (0.63 kg C m-2 yr-1) over 2-fold greater than the untreated control (0.28 kg C m-2 yr-1). This study demonstrates the feasibility of using constructed wetlands treated with coagulants to reverse subsidence by accreting the

  16. [Molecular genetic analysis for a pedigree with severe hereditary coagulation factor VII deficiency].

    PubMed

    Ding, Qiu-lan; Wang, Hong-li; Wang, Xue-feng; Wang, Ming-shan; Fu, Qi-hua; Wu, Wen-man; Hu, Yi-qun; Wang, Zhen-yi

    2003-10-01

    To identify the genetic mutations of a severe inherited coagulation factor VII (FVII) deficiency pedigree. The diagnosis was validated by coagulant and haemostatic parameters. FVII gene mutations were screened in the propositus and his family members by DNA direct sequencing and confirmed by digestions of the restriction enzymes of the PCR production. Two heterozygous missense mutations were found in the propositus of the pedigree: a G to T transversion at position 9482 in exon 6 and a C to T mutation at position 11348 in exon 8 resulting in the amino acid substitution of Arg152 with Leu and Arg304 with Trp, respectively. A heterozygous single nucleotide deletion (C) at position 11487-11489(CCC) within exon 8 was identified, which predicted the frameshift mutation at position His351 followed by the changes of six corresponding amino acids and appearance of a premature protein caused by stop codon. The heterozygous mutations identified in the proband were derived from his father (Arg152 to Leu) and his mother (Arg304 to Trp mutation) and a heterozygous deletion (C) at position 11487-9(CCC). By tracing the other pedigree members, it was found that his grandmother had a heterozygous mutation of Arg304Trp and a heterozygous polymorphism of Arg353Gln and his grandfather had a heterozygous Arg152Leu mutation. Three heterozygous mutations were found in a pedigree with hereditary coagulation factor VII deficiency. Arg152Leu and deletion C at position 11487-9(CCC) were novel mutations.

  17. Internal Quality Control Practices in Coagulation Laboratories: recommendations based on a patterns-of-practice survey.

    PubMed

    McFarlane, A; Aslan, B; Raby, A; Moffat, K A; Selby, R; Padmore, R

    2015-12-01

    Internal quality control (IQC) procedures are crucial for ensuring accurate patient test results. The IQMH Centre for Proficiency Testing conducted a web-based survey to gather information on the current IQC practices in coagulation testing. A questionnaire was distributed to 174 Ontario laboratories licensed to perform prothrombin time (PT) and activated partial thromboplastin time (APTT). All laboratories reported using two levels of commercial QC (CQC); 12% incorporate pooled patient plasma into their IQC program; >68% run CQC at the beginning of each shift; 56% following maintenance, with reagent changes, during a shift, or with every repeat sample; 6% only run CQC at the beginning of the day and 25% when the instruments have been idle for a defined period of time. IQC run frequency was determined by manufacturer recommendations (71%) but also influenced by the stability of test (27%), clinical impact of an incorrect test result (25%), and sample's batch number (10%). IQC was monitored using preset limits based on standard deviation (66%), precision goals (46%), or allowable performance limits (36%). 95% use multirules. Failure actions include repeating the IQC (90%) and reporting patient results; if repeat passes, 42% perform repeat analysis of all patient samples from last acceptable IQC. Variability exists in coagulation IQC practices among Ontario clinical laboratories. The recommendations presented here would be useful in encouraging standardized IQC practices. © 2015 John Wiley & Sons Ltd.

  18. Use of thermo‐coagulation as an alternative treatment modality in a ‘screen‐and‐treat’ programme of cervical screening in rural Malawi

    PubMed Central

    Kafwafwa, Savel; Brown, Hilary; Walker, Graeme; Madetsa, Belito; Deeny, Miriam; Kabota, Beatrice; Morton, David; Ter Haar, Reynier; Grant, Liz; Cubie, Heather A.

    2016-01-01

    The incidence of cervical cancer in Malawi is the highest in the world and projected to increase in the absence of interventions. Although government policy supports screening using visual inspection with acetic acid (VIA), screening provision is limited due to lack of infrastructure, trained personnel, and the cost and availability of gas for cryotherapy. Recently, thermo‐coagulation has been acknowledged as a safe and acceptable procedure suitable for low‐resource settings. We introduced thermo‐coagulation for treatment of VIA‐positive lesions as an alternative to cryotherapy within a cervical screening service based on VIA, coupled with appropriate, sustainable pathways of care for women with high‐grade lesions and cancers. Detailed planning was undertaken for VIA clinics, and approvals were obtained from the Ministry of Health, Regional and Village Chiefs. Educational resources were developed. Thermo‐coagulators were introduced into hospital and health centre settings, with theoretical and practical training in safe use and maintenance of equipment. A total of 7,088 previously unscreened women attended VIA clinics between October 2013 and March 2015. Screening clinics were held daily in the hospital and weekly in the health centres. Overall, VIA positivity was 6.1%. Almost 90% received same day treatment in the hospital setting, and 3‐ to 6‐month cure rates of more than 90% are observed. Thermo‐coagulation proved feasible and acceptable in this setting. Effective implementation requires comprehensive training and provider support, ongoing competency assessment, quality assurance and improvement audit. Thermo‐coagulation offers an effective alternative to cryotherapy and encouraged VIA screening of many more women. PMID:27006131

  19. [Combined use of active chlorine and coagulants for drinking water purification and disinfection].

    PubMed

    Rakhmanin, Iu A; Zholdakova, Z I; Poliakova, E E; Kir'ianova, L F; Miasnikov, I N; Tul'skaia, E A; Artemova, T Z; Ivanova, L V; Dmitrieva, R A; Doskina, T V

    2004-01-01

    The authors made an experimental study of the efficiency of water purification procedures based on the combined use of active chlorine and coagulants and hygienically evaluated the procedures. The study included the evaluation of water disinfection with various coagulants and active chlorine; the investigation of the processes of production of deleterious organic chlorine compounds; the assessment of the quality of water after its treatment. The coagulants representing aluminum polyoxychloride: RAX-10 (AQUA-AURATE 10) and RAX-18 (AQUA-AURATE 18), and aluminum sulfate, technically pure grade were tested. The treatment of river water with the coagulants RAX-10 and RAX-18, followed by precipitation, filtration, and chlorination under laboratory conditions, was shown to result in water disinfection to the levels complying with the requirements described in SanPiN 2.1.4.1074-01. RAX-18 showed the best disinfecting activity against total and heat-tolerant coliform bacteria, but also to the highly chlorine-resistant microrganisms--the spores of sulfite-reducing Clostridia, phages, and viruses. Since the coagulants have an increased sorptive capacity relative to humus and other organic substances, substitution of primary chlorination for coagulant treatment may induce a reduction in the risk of formation of oncogenically and mutagenically hazardous chlorinated hydrocarbons.

  20. Intraoperative Changes in Blood Coagulation and Thrombelastographic Monitoring in Liver Transplantation

    PubMed Central

    Kang, Yoo Goo; Martin, Douglas J.; Marquez, Jose; Lewis, Jessica H.; Bontempo, Franklin A.; Shaw, Byers W.; Starzl, Thomas E.; Winter, Peter M.

    2010-01-01

    The blood coagulation system of 66 consecutive patients undergoing consecutive liver transplantations was monitored by thrombelastograph and analytic coagulation profile. A poor preoperative coagulation state, decrease in levels of coagulation factors, progressive fibrinolysis, and whole blood clot lysis were observed during the preanhepatic and anhepatic stages of surgery. A further general decrease in coagulation factors and platelets, activation of fibrinolysis, and abrupt decrease in levels of factors V and VIII occurred before and with reperfusion of the homograft. Recovery of blood coagulability began 30–60 min after reperfusion of the graft liver, and coagulability had returned toward baseline values 2 hr after reperfusion. A positive correlation was shown between the variables of thrombelastography and those of the coagulation profile. Thrombelastography was shown to be a reliable and rapid monitoring system. Its use was associated with a 33% reduction of blood and fluid infusion volume, whereas blood coagulability was maintained without an increase in the number of blood product donors. PMID:3896028

  1. Comparison of the Haemodynamic Effects of Three Different Methods at the Induction of Anaesthesia

    PubMed Central

    Uygur, Mehmet Levent; Ersoy, Ayşın; Altan, Aysel; Ervatan, Zekeriya; Kamalı, Sedat

    2014-01-01

    Objective Haemodynamic variations are inevitable during induction of anaesthetic drugs. The present study investigates the haemodynamic variations of three different drugs (thiopental, propofol, and etomidate) used for induction of general anaesthesia together with fentanyl. Methods In a randomized, double-blind study, 45 patients were assigned to one of three groups (n=15 each). Fentanyl 1 μg kg−1 was injected over 60 sec followed by propofol 2 mg kg−1 (Group P), thiopentone 6 mg kg−1 (Group T), or etomidate 0.3 mg kg−1 (Group E). Noninvasive measurements of systolic arterial pressure (SAP), diastolic arterial pressure (DAP), mean arterial pressure (MAP), and heart rate (HR) was performed on admittance, immediately before the induction of anaesthesia, and 1, 3, and 5 min thereafter. Cardiac output (CO) values were recorded before induction, immediately after the injection of the drug, and at 1 min after the intubation. Results In all groups, during the study period, SAP, DAP, MAP, and CO values decreased with respect to time before induction. Following the administration of the induction dose of propofol (Group P), a significantly greater decrease of systolic and diastolic blood pressure was observed with etomidate (Group E) or thiopentone (Group T). Decrease in CO was also more marked with propofol (Group P) than with etomidate (Group E) or thiopentone (Group T). Conclusion It’s concluded that, in this study, the combination of fentanyl-etomidate is safer than both the groups of fentanyl-propofol and fentanyl-thiopental in terms of providing haemodynamic stability. PMID:27366443

  2. Removal of acetaminophen and naproxen by combined coagulation and adsorption using biochar: influence of combined sewer overflow components.

    PubMed

    Jung, Chanil; Oh, Jeill; Yoon, Yeomin

    2015-07-01

    The combined coagulation and adsorption of targeted acetaminophen and naproxen using activated biochar and aluminum sulfate were studied under various synthetic "combined sewer overflow" (CSO) conditions. The biochar demonstrated better adsorption performance for both acetaminophen and naproxen (removal, 94.1 and 97.7%, respectively) than that of commercially available powdered activated carbon (removal, 81.6 and 94.1%, respectively) due to superior carbonaceous structure and surface properties examined by nuclear magnetic resonance analysis. The adsorption of naproxen was more favorable, occupying active adsorption sites on the adsorbents by naproxen due to its higher adsorption affinity compared to acetaminophen. Three classified CSO components (i.e., representing hydrophobic organics, hydrophilic organics, and inorganics) played different roles in the adsorption of both adsorbates, resulted in inhibition by humic acid complexation or metal ligands and negative electrostatic repulsion under adsorption and coagulation combined system. Adsorption alone with biochar was determined to be the most effective adsorptive condition for the removal of both acetaminophen and naproxen under various CSO conditions, while both coagulation alone and combined adsorption and coagulation failed to remove the acetaminophen and naproxen adequately due to an increase in ionic strength in the presence of spiked aluminum species derived from the coagulant.

  3. [The implantation of bipolar coagulation to remove endometriosis foci].

    PubMed

    Sobkiewicz, S; Palatyński, A; Salata, I

    2001-05-01

    The paper compares the results of bipolar coagulation bey means of ERBE ICC 300 diatermy coagulator and WISAP endocoagulator. The results of both types of coagulation were assessed with reference to the changes occurring on peritoneum ligamenti sacro-uterini, Douglas pouch and ovary. The best results of endometriosis foci coagulation were obtained with bipolar ball at 20-30 W; no side effects or feelings of malaise were observed in patients just after the operation or over a longer period of convalescence.

  4. In vitro thermal profile suitability assessment of acids and bases for thermochemical ablation: underlying principles.

    PubMed

    Freeman, Laura A; Anwer, Bilal; Brady, Ryan P; Smith, Benjamin C; Edelman, Theresa L; Misselt, Andrew J; Cressman, Erik N K

    2010-03-01

    To measure and compare temperature changes in a recently developed gel phantom for thermochemical ablation as a function of reagent strength and concentration with several acids and bases. Aliquots (0.5-1 mL) of hydrochloric acid or acetic acid and sodium hydroxide or aqueous ammonia were injected for 5 seconds into a hydrophobic gel phantom. Stepwise increments in concentration were used to survey the temperature changes caused by these reactions. Injections were performed in triplicate, measured with a thermocouple probe, and plotted as functions of concentration and time. Maximum temperatures were reached almost immediately in all cases, reaching 75 degrees C-110 degrees C at the higher concentrations. The highest temperatures were seen with hydrochloric acid and either base. More concentrated solutions of sodium hydroxide tended to mix incompletely, such that experiments at 9 M and higher were difficult to perform consistently. Higher concentrations for any reagent resulted in higher temperatures. Stronger acid and base combinations resulted in higher temperatures versus weak acid and base combinations at the same concentration. Maximum temperatures obtained are in a range known to cause tissue coagulation, and all combinations tested therefore appeared suitable for further investigation in thermochemical ablation. Because of the loss of the reaction chamber shape at higher concentrations of stronger agents, the phantom does not allow complete characterization under these circumstances. Adequate mixing of reagents to maximize heating potential and avoid systemic exposure to unreacted acid and base must be addressed if the method is to be safely employed in tissues. In addition, understanding factors that control lesion shape in a more realistic tissue model will be critical. Copyright 2010 SIR. Published by Elsevier Inc. All rights reserved.

  5. Biological and analytical variations of 16 parameters related to coagulation screening tests and the activity of coagulation factors.

    PubMed

    Chen, Qian; Shou, Weiling; Wu, Wei; Guo, Ye; Zhang, Yujuan; Huang, Chunmei; Cui, Wei

    2015-04-01

    To accurately estimate longitudinal changes in individuals, it is important to take into consideration the biological variability of the measurement. The few studies available on the biological variations of coagulation parameters are mostly outdated. We confirmed the published results using modern, fully automated methods. Furthermore, we added data for additional coagulation parameters. At 8:00 am, 12:00 pm, and 4:00 pm on days 1, 3, and 5, venous blood was collected from 31 healthy volunteers. A total of 16 parameters related to coagulation screening tests as well as the activity of coagulation factors were analyzed; these included prothrombin time, fibrinogen (Fbg), activated partial thromboplastin time, thrombin time, international normalized ratio, prothrombin time activity, activated partial thromboplastin time ratio, fibrin(-ogen) degradation products, as well as the activity of factor II, factor V, factor VII, factor VIII, factor IX, and factor X. All intraindividual coefficients of variation (CVI) values for the parameters of the screening tests (except Fbg) were less than 5%. Conversely, the CVI values for the activity of coagulation factors were all greater than 5%. In addition, we calculated the reference change value to determine whether a significant difference exists between two test results from the same individual. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. The application of bioflocculant for the removal of humic acids from stabilized landfill leachates.

    PubMed

    Zouboulis, Anastasios I; Chai, Xiao-Li; Katsoyiannis, Ioannis A

    2004-01-01

    The evaluation of bioflocculant, in comparison with traditional inorganic coagulants, for the removal of humic acids from landfill leachates stabilized by biological treatment, was performed using conventional jar-test coagulation experiments. The optimized conditions (pH and coagulant dosage) were identified for the treatment of synthetic solutions as well as for biologically pre-treated landfill leachates. It was found that the application of bioflocculant was quite efficient in the removal of humic acids from synthetic solutions as well as in the reduction of COD content from real landfill leachates. The optimal pH value was found to be between 7 and 7.5, while a 20 mg/l bioflocculant dosage was sufficient in providing more than 85% humic acid removal. The results were comparable with those obtained by the application of conventional coagulants such as alum or polyaluminum chloride; therefore, bioflocculant can be considered as a viable alternative in the treatment of landfill leachates applying coagulation.

  7. Wet spinning of solid polyamic acid fibers

    NASA Technical Reports Server (NTRS)

    Dorogy, William E., Jr. (Inventor); Saintclair, Anne K. (Inventor)

    1989-01-01

    The invention is a process for the production of solid aromatic polyamic acid and polyimide fibers from a wet gel or coagulation bath wet gel using N,N-dimethylacetamide (DMAc) solution of the polyamic acid derived from aromatic dianhydrides such as 3,3',4,4'-benzo phenone tetracarboxylic dianhydride (BTDA) and aromatic diamines such as 4,4'oxydianiline (4,4'-ODA). By utilizing the interrelationship between coagulation medium and concentration, resin inherent viscosity, resin percent solids, filament diameter, and fiber void content, it is possible to make improved polyamic acid fibers. Solid polyimide fibers, obtained by the thermal cyclization of the polyamic acid precursor, have increased tensile properties compared to fibers containing macropores from the same resin system.

  8. Wet spinning of solid polyamic acid fibers

    NASA Technical Reports Server (NTRS)

    Dorogy, William E., Jr. (Inventor); St.clair, Anne K. (Inventor)

    1991-01-01

    The invention is a process for the production of solid aromatic polyamic acid and polyimide fibers from a wet gel or coagulation bath wet gel using N,N-dimethylacetamide (DMAc) solutions of the polyamic acid derived from aromatic dianhydrides such as 3,3',4,4' benzophenonetetra carboxylic dianhydride (BTDA) and aromatic diamines such as 4,4'-oxydianiline (4,4'-ODA). By utilizing the relationship among coagulation medium and concentration, resin inherent viscosity, resin percent solids, filament diameter, and fiber void content, it is possible to make improved polyamic acid fibers. Solid polyimide fibers, obtained by the thermal cyclization of the polyamic acid precursor, have increased tensile properties compared to fibers containing macropores from the same resin system.

  9. Coagulation of Dust Particles in Argon Plasma of RF Discharge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mankelevich, Yu. A.; Olevanov, M. A.; Pal, A. F.

    2008-09-07

    The experiments on coagulation of poly-disperse particles with various size distributions injected into the argon plasma of the magnetron radio-frequency discharge are discussed. The experiments were carried out under the conditions similar to those using dusty plasma for technology applications. Within the created theory the threshold behavior of the coagulation process was explained for the first time, the estimation of the critical particle size for onset of a fast coagulation was made, and the analytical calculation of the coagulation rate of dust particles was performed. The proposed coagulation mechanism makes it possible to describe the typical features of coagulation processesmore » observed in experiments and to explain the effects of attraction and coalescence of highly negatively charged microns size particles.« less

  10. [Removal of DON in micro-polluted raw water by coagulation and adsorption using activated carbon].

    PubMed

    Liu, Bing; Yu, Guo-Zhong; Gu, Li; Zhao, Cheng-Mei; Li, Qing-Fei; Zhai, Hui-Min

    2013-04-01

    Dissolved organic nitrogen as a precursor of new type nitrogenous disinfection by-products in drinking water attracted gradually the attention of scholars all over the world. In order to explore the mechanism of DON removal in micro-polluted raw water by coagulation and adsorption, water quality parameters, such as DON, DOC, NH4(+) -N, UV254, pH and dissolved oxygen, were determined in raw water and the molecular weight distribution of the DON and DOC was investigated. The variations in DON, DOC and UV254 in the coagulation and adsorption tests were investigated, and the changes of DON in raw water were characterized using three-dimensional fluorescence spectroscopy. The results showed that DON, DOC and UV254 were 1.28 mg x L(-1), 8.56 mg x L(-1), 0.16 cm(-1), and DOC/DON and SUVA were 6.69 mg x mg(-1), 1.87 m(-1) x (mg x L(-1))(-1) in raw water, respectively. The molecular weight distribution of the DON in raw water showed a bimodal distribution. The small molecular weight (< 6 000) fractions accounted for a high proportion of 68% and the large (> 20 000) fractions accounted for about 22%. The removal of DON, DOC and UV254 was about 20%, 26% and 70%, respectively, in the coagulation test and the dosage of coagulant was 10 mg x L(-1). The removal of DON, DOC and UV254 was about 60%, 35% and 100%, respectively, in the adsorption test and the dosage of activated carbon was 1.0 g. In the combination of coagulation and adsorption, the removal of DON and DOC reached approximately 82% and 64%, respectively. 3DEEM revealed that the variation of DON in the coagulation and adsorption tests depended intimately on tryptophan protein-like substances, aromatic protein-like substances and fulvic acid-like substances.

  11. Probing Coagulation Behavior of Individual Aluminum Species for Removing Corresponding Disinfection Byproduct Precursors: The Role of Specific Ultraviolet Absorbance

    PubMed Central

    Zhao, He; Hu, Chengzhi; Zhang, Di; Liu, Huijuan; Qu, Jiuhui

    2016-01-01

    Coagulation behavior of aluminum chloride and polyaluminum chloride (PACl) for removing corresponding disinfection byproduct (DBP) precursors was discussed in this paper. CHCl3, bromine trihalomethanes (THM-Br), dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA) formation potential yields were correlated with specific ultraviolet absorbance (SUVA) values in different molecular weight (MW) fractions of humic substances (HS), respectively. Correlation analyses and principal component analysis were performed to examine the relationships between SUVA and different DBP precursors. To acquire more structural characters of DBP precursors and aluminum speciation, freeze-dried precipitates were analyzed by fourier transform infrared (FTIR) and C 1s, Al 2p X-ray photoelectron spectroscopy (XPS). The results indicated that TCAA precursors (no MW limits), DCAA and CHCl3 precursors in low MW fractions (MW<30 kDa) had a relatively good relations with SUVA values. These DBP precursors were coagulated more easily by in situ Al13 of AlCl3 at pH 5.0. Due to relatively low aromatic content and more aliphatic structures, THM-Br precursors (no MW limits) and CHCl3 precursors in high MW fractions (MW>30 kDa) were preferentially removed by PACl coagulation with preformed Al13 species at pH 5.0. Additionally, for DCAA precursors in high MW fractions (MW>30 kDa) with relatively low aromatic content and more carboxylic structures, the greatest removal occurred at pH 6.0 through PACl coagulation with aggregated Al13 species. PMID:26824243

  12. Use of thermo-coagulation as an alternative treatment modality in a 'screen-and-treat' programme of cervical screening in rural Malawi.

    PubMed

    Campbell, Christine; Kafwafwa, Savel; Brown, Hilary; Walker, Graeme; Madetsa, Belito; Deeny, Miriam; Kabota, Beatrice; Morton, David; Ter Haar, Reynier; Grant, Liz; Cubie, Heather A

    2016-08-15

    The incidence of cervical cancer in Malawi is the highest in the world and projected to increase in the absence of interventions. Although government policy supports screening using visual inspection with acetic acid (VIA), screening provision is limited due to lack of infrastructure, trained personnel, and the cost and availability of gas for cryotherapy. Recently, thermo-coagulation has been acknowledged as a safe and acceptable procedure suitable for low-resource settings. We introduced thermo-coagulation for treatment of VIA-positive lesions as an alternative to cryotherapy within a cervical screening service based on VIA, coupled with appropriate, sustainable pathways of care for women with high-grade lesions and cancers. Detailed planning was undertaken for VIA clinics, and approvals were obtained from the Ministry of Health, Regional and Village Chiefs. Educational resources were developed. Thermo-coagulators were introduced into hospital and health centre settings, with theoretical and practical training in safe use and maintenance of equipment. A total of 7,088 previously unscreened women attended VIA clinics between October 2013 and March 2015. Screening clinics were held daily in the hospital and weekly in the health centres. Overall, VIA positivity was 6.1%. Almost 90% received same day treatment in the hospital setting, and 3- to 6-month cure rates of more than 90% are observed. Thermo-coagulation proved feasible and acceptable in this setting. Effective implementation requires comprehensive training and provider support, ongoing competency assessment, quality assurance and improvement audit. Thermo-coagulation offers an effective alternative to cryotherapy and encouraged VIA screening of many more women. © 2016 The Authors International Journal of Cancer published by John Wiley & Sons Ltd on behalf of UICC.

  13. Upregulation of the coagulation factor VII gene during glucose deprivation is mediated by activating transcription factor 4.

    PubMed

    Cronin, Katherine R; Mangan, Thomas P; Carew, Josephine A

    2012-01-01

    Constitutive production of blood coagulation proteins by hepatocytes is necessary for hemostasis. Stressful conditions trigger adaptive cellular responses and delay processing of most proteins, potentially affecting plasma levels of proteins secreted exclusively by hepatocytes. We examined the effect of glucose deprivation on expression of coagulation proteins by the human hepatoma cell line, HepG2. Expression of coagulation factor VII, which is required for initiation of blood coagulation, was elevated by glucose deprivation, while expression of other coagulation proteins decreased. Realtime PCR and ELISA demonstrated that the relative percentage expression +/- SD of steady-state F7 mRNA and secreted factor VII antigen were significantly increased (from 100+/-15% to 188+/-27% and 100+/-8.8% to 176.3+/-17.3% respectively, p<0.001) at 24 hr of treatment. The integrated stress response was induced, as indicated by upregulation of transcription factor ATF4 and of additional stress-responsive genes. Small interfering RNAs directed against ATF4 potently reduced basal F7 expression, and prevented F7 upregulation by glucose deprivation. The response of the endogenous F7 gene was replicated in reporter gene assays, which further indicated that ATF4 effects were mediated via interaction with an amino acid response element in the F7 promoter. Our data indicated that glucose deprivation enhanced F7 expression in a mechanism reliant on prior ATF4 upregulation primarily due to increased transcription from the ATF4 gene. Of five coagulation protein genes examined, only F7 was upregulated, suggesting that its functions may be important in a systemic response to glucose deprivation stress.

  14. [Effect of ferrate preoxidation on coagulation of Songhua River].

    PubMed

    Li, Chun-juan; Ma, Jun; Liang, Tao

    2008-06-01

    The preoxidation of polluted surface water with ferrate was conducted with respect to its impact on the following coagulation. It can be seen that UV254-absorbance, turbidity and TOC substantially decreased by 36.7%, 80.2%, 31.1%, respectively, after coagulation, without ferrate preoxidation, and by 63.3%, 89.6%, 37.0%, respectively, after coagulation, with ferrate preoxidation. It is noted that NH4+-N concentration is increased by 17% after coagulation with ferrate. This phenomenon can be explained by the fact that organics containing nitrogen in raw water were partly oxidized to inorganic nitrogen by ferrate preoxidation. After coagulation, AOC and AOC/TOC are increased from 998 microg x L(-1) to 1241 microg x L(-1), from 28.4% to 38.7%, respectively, by ferrate preoxidation. AOC-P17/AOC after coagulation is up to 83% with ferrate preoxidation. These suggest that preoxidation with ferrate promoted the biodegradation of organics with substantial increases of AOC, AOC/TOC. The results indicate that the concentration of organics with relative molecular mass (Mr) of 10000-100000 and less than 500 were substantially increased after the raw water was coagulated with ferrate preoxidation, which suggested that some high molecular weight organic substances were broken into smaller ones during ferrate preoxidation. After coagulation, organics of less than Mr = 500 in TOC are increased up to 65.0% with preoxidation from 38.9% without ferrate preoxidation. These oxidation products are biodegradable.

  15. Zeolite-based hemostat QuikClot releases calcium into blood and promotes blood coagulation in vitro

    PubMed Central

    Li, Jing; Cao, Wei; Lv, Xiao-xing; Jiang, Li; Li, Yue-jun; Li, Wang-zhou; Chen, Shao-zong; Li, Xue-yong

    2013-01-01

    Aim: To examine the changes in electrolyte concentrations after addition of zeolite-based hemostat QuikClot in blood and the effects of zeolite on blood coagulation in vitro. Methods: Fresh blood was taken from healthy adult volunteers and sheep, and the electrolyte concentrations in blood were measured using a blood electrolyte analyzer. Zeolite Saline Solution (ZSS) was prepared by addition of 2 g zeolite to 0.9% NaCl solution (4, 8, or 16 mL). The electrolytes in ZSS were measured using inductively coupled plasma atomic emission spectroscopy. The prothrombin time (PT) and activated partial thromboplastin time (APTT) of blood were measured using the test tube method. The activated clotting time (ACT) and clotting rate (CR) of blood were measured with Sonoclot Coagulation and Platelet Function Analyzer. Results: Addition of zeolite (50 and 100 mg) in 2 mL human blood significantly increased Ca2+ concentration, while Na+ and K+ concentrations were significantly decreased. Addition of zeolite (50 and 100 mg) in 0.9% NaCl solution (2 mL) caused similar changes in Ca2+ and Na+ concentrations. Si4+ (0.2434 g/L) and Al3+ (0.2575 g/L) were detected in ZSS (2 g/8 mL). Addition of ZSS in sheep blood shortened APTT in a concentration dependent manner, without changing PT. ZSS or aqueous solution of CaCl2 that contained Ca2+ concentration identical to that of ZSS significantly shortened ACT in human blood without significantly changing CR, and the effect of ZSS on ACT was not significantly different from that of CaCl2. Conclusion: Zeolite releases Ca2+ into blood, thus accelerating the intrinsic pathway of blood coagulation and shortening the clot formation time. PMID:23334236

  16. Zeolite-based hemostat QuikClot releases calcium into blood and promotes blood coagulation in vitro.

    PubMed

    Li, Jing; Cao, Wei; Lv, Xiao-xing; Jiang, Li; Li, Yue-jun; Li, Wang-zhou; Chen, Shao-zong; Li, Xue-yong

    2013-03-01

    To examine the changes in electrolyte concentrations after addition of zeolite-based hemostat QuikClot in blood and the effects of zeolite on blood coagulation in vitro. Fresh blood was taken from healthy adult volunteers and sheep, and the electrolyte concentrations in blood were measured using a blood electrolyte analyzer. Zeolite Saline Solution (ZSS) was prepared by addition of 2 g zeolite to 0.9% NaCl solution (4, 8, or 16 mL). The electrolytes in ZSS were measured using inductively coupled plasma atomic emission spectroscopy. The prothrombin time (PT) and activated partial thromboplastin time (APTT) of blood were measured using the test tube method. The activated clotting time (ACT) and clotting rate (CR) of blood were measured with Sonoclot Coagulation and Platelet Function Analyzer. Addition of zeolite (50 and 100 mg) in 2 mL human blood significantly increased Ca(2+) concentration, while Na(+) and K(+) concentrations were significantly decreased. Addition of zeolite (50 and 100 mg) in 0.9% NaCl solution (2 mL) caused similar changes in Ca(2+) and Na(+) concentrations. Si(4+) (0.2434 g/L) and Al(3+) (0.2575 g/L) were detected in ZSS (2 g/8 mL). Addition of ZSS in sheep blood shortened APTT in a concentration dependent manner, without changing PT. ZSS or aqueous solution of CaCl2 that contained Ca(2+) concentration identical to that of ZSS significantly shortened ACT in human blood without significantly changing CR, and the effect of ZSS on ACT was not significantly different from that of CaCl2. Zeolite releases Ca(2+) into blood, thus accelerating the intrinsic pathway of blood coagulation and shortening the clot formation time.

  17. Laser tissue coagulation and concurrent optical coherence tomography through a double-clad fiber coupler.

    PubMed

    Beaudette, Kathy; Baac, Hyoung Won; Madore, Wendy-Julie; Villiger, Martin; Godbout, Nicolas; Bouma, Brett E; Boudoux, Caroline

    2015-04-01

    Double-clad fiber (DCF) is herein used in conjunction with a double-clad fiber coupler (DCFC) to enable simultaneous and co-registered optical coherence tomography (OCT) and laser tissue coagulation. The DCF allows a single channel fiber-optic probe to be shared: i.e. the core propagating the OCT signal while the inner cladding delivers the coagulation laser light. We herein present a novel DCFC designed and built to combine both signals within a DCF (>90% of single-mode transmission; >65% multimode coupling). Potential OCT imaging degradation mechanisms are also investigated and solutions to mitigate them are presented. The combined DCFC-based system was used to induce coagulation of an ex vivo swine esophagus allowing a real-time assessment of thermal dynamic processes. We therefore demonstrate a DCFC-based system combining OCT imaging with laser coagulation through a single fiber, thus enabling both modalities to be performed simultaneously and in a co-registered manner. Such a system enables endoscopic image-guided laser marking of superficial epithelial tissues or laser thermal therapy of epithelial lesions in pathologies such as Barrett's esophagus.

  18. Laser tissue coagulation and concurrent optical coherence tomography through a double-clad fiber coupler

    PubMed Central

    Beaudette, Kathy; Baac, Hyoung Won; Madore, Wendy-Julie; Villiger, Martin; Godbout, Nicolas; Bouma, Brett E.; Boudoux, Caroline

    2015-01-01

    Double-clad fiber (DCF) is herein used in conjunction with a double-clad fiber coupler (DCFC) to enable simultaneous and co-registered optical coherence tomography (OCT) and laser tissue coagulation. The DCF allows a single channel fiber-optic probe to be shared: i.e. the core propagating the OCT signal while the inner cladding delivers the coagulation laser light. We herein present a novel DCFC designed and built to combine both signals within a DCF (>90% of single-mode transmission; >65% multimode coupling). Potential OCT imaging degradation mechanisms are also investigated and solutions to mitigate them are presented. The combined DCFC-based system was used to induce coagulation of an ex vivo swine esophagus allowing a real-time assessment of thermal dynamic processes. We therefore demonstrate a DCFC-based system combining OCT imaging with laser coagulation through a single fiber, thus enabling both modalities to be performed simultaneously and in a co-registered manner. Such a system enables endoscopic image-guided laser marking of superficial epithelial tissues or laser thermal therapy of epithelial lesions in pathologies such as Barrett’s esophagus. PMID:25909013

  19. HACE1-dependent protein degradation provides cardiac protection in response to haemodynamic stress

    NASA Astrophysics Data System (ADS)

    Zhang, Liyong; Chen, Xin; Sharma, Parveen; Moon, Mark; Sheftel, Alex D.; Dawood, Fayez; Nghiem, Mai P.; Wu, Jun; Li, Ren-Ke; Gramolini, Anthony O.; Sorensen, Poul H.; Penninger, Josef M.; Brumell, John H.; Liu, Peter P.

    2014-03-01

    The HECT E3 ubiquitin ligase HACE1 is a tumour suppressor known to regulate Rac1 activity under stress conditions. HACE1 is increased in the serum of patients with heart failure. Here we show that HACE1 protects the heart under pressure stress by controlling protein degradation. Hace1 deficiency in mice results in accelerated heart failure and increased mortality under haemodynamic stress. Hearts from Hace1-/- mice display abnormal cardiac hypertrophy, left ventricular dysfunction, accumulation of LC3, p62 and ubiquitinated proteins enriched for cytoskeletal species, indicating impaired autophagy. Our data suggest that HACE1 mediates p62-dependent selective autophagic turnover of ubiquitinated proteins by its ankyrin repeat domain through protein-protein interaction, which is independent of its E3 ligase activity. This would classify HACE1 as a dual-function E3 ligase. Our finding that HACE1 has a protective function in the heart in response to haemodynamic stress suggests that HACE1 may be a potential diagnostic and therapeutic target for heart disease.

  20. Evaluation of Optical Coherence Tomography for the Measurement of the Effects of Activators and Anticoagulants on the Blood Coagulation In Vitro

    PubMed Central

    Geng, Jinhai; Liu, Gangjun; Chen, Zhongping

    2013-01-01

    Optical properties of human blood during coagulation were studied using optical coherence tomography (OCT) and the parameter of clotting time derived from the 1/e light penetration depth (d1/e) versus time was developed in our previous work. In this study, in order to know if a new OCT test can characterize the blood-coagulation process under different treatments in vitro, the effects of two different activators (calcium ions and thrombin) and anticoagulants, i.e., acetylsalicylic acid (ASA, a well-known drug aspirin) and melagatran (a direct thrombin inhibitor), at various concentrations are evaluated. A swept-source OCT system with a 1300 nm center wavelength is used for detecting the blood-coagulation process in vitro under a static condition. A dynamic study of d1/e reveals a typical behavior due to coagulation induced by both calcium ions and thrombin, and the clotting time is concentration-dependent. Dose-dependent ASA and melagatran prolong the clotting times. ASA and melagatran have different effects on blood coagulation. As expected, melagatran is much more effective than ASA in anticoagulation by the OCT measurements. The OCT assay appears to be a simple method for the measurement of blood coagulation to assess the effects of activators and anticoagulants, which can be used for activator and anticoagulant screening. PMID:23392340

  1. Evaluation of optical coherence tomography for the measurement of the effects of activators and anticoagulants on the blood coagulation in vitro.

    PubMed

    Xu, Xiangqun; Geng, Jinhai; Liu, Gangjun; Chen, Zhongping

    2013-08-01

    Optical properties of human blood during coagulation were studied using optical coherence tomography (OCT) and the parameter of clotting time derived from the 1/e light penetration depth (d(1/e)) versus time was developed in our previous work. In this study, in order to know if a new OCT test can characterize the blood-coagulation process under different treatments in vitro, the effects of two different activators (calcium ions and thrombin) and anticoagulants, i.e., acetylsalicylic acid (ASA, a well-known drug aspirin) and melagatran (a direct thrombin inhibitor), at various concentrations are evaluated. A swept-source OCT system with a 1300 nm center wavelength is used for detecting the blood-coagulation process in vitro under a static condition. A dynamic study of d1/e reveals a typical behavior due to coagulation induced by both calcium ions and thrombin, and the clotting time is concentration-dependent. Dose-dependent ASA and melagatran prolong the clotting times. ASA and melagatran have different effects on blood coagulation. As expected, melagatran is much more effective than ASA in anticoagulation by the OCT measurements. The OCT assay appears to be a simple method for the measurement of blood coagulation to assess the effects of activators and anticoagulants, which can be used for activator and anticoagulant screening.

  2. Different Recovery Profiles of Coagulation Factors, Thrombin Generation, and Coagulation Function After Hemorrhagic Shock in Pigs

    DTIC Science & Technology

    2012-06-06

    Different recovery profiles of coagulation factors, thrombin generation, and coagulation function after hemorrhagic shock in pigs Wenjun Z. Martini ...Defense. Address for reprints: Wenjun Z. Martini , PhD, The US Army Institute of Surgical Research, 3698 Chambers Pass, Ft. Sam Houston, San Antonio, TX...control number 1. REPORT DATE 01 SEP 2015 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Different recovery profiles of

  3. Non-invasive measurement of the haemodynamic effects of inhaled salbutamol, intravenous L-arginine and sublingual nitroglycerin

    PubMed Central

    Tahvanainen, Anna; Leskinen, Miia; Koskela, Jenni; Ilveskoski, Erkki; Alanko, Juha; Kähönen, Mika; Kööbi, Tiit; Lehtimäki, Lauri; Moilanen, Eeva; Mustonen, Jukka; Pörsti, Ilkka

    2009-01-01

    AIMS To examine the effects of salbutamol and L-arginine, two compounds acting largely on the endothelium, and the endothelium-independent agent nitroglycerin on blood pressure, arterial compliance, cardiac function and vascular resistance. METHODS Continuous radial pulse wave analysis, whole-body impedance cardiography, and plethysmographic blood pressure from fingers in the supine position and during head-up tilt were recorded in nine healthy subjects. Data were captured before and after L-arginine (10 mg mg−1 min−1) or saline infusion, salbutamol (400 µg) or placebo inhalation, and sublingual nitroglycerin (0.25 mg) or placebo resoriblet. RESULTS The results of all measurements were comparable before drug administration. The effects of inhaled salbutamol were apparent in the supine position: systemic vascular resistance (−9.2 ± 2.6%) and augmentation index (−4.0 ± 1.5%) decreased, and heart rate (8.6 ± 2.5%) and cardiac output (8.8 ± 3.1%) increased. L-arginine had no clear effects on supine haemodynamics, but during head-up tilt blood pressure was moderately decreased and reduction in aortic reflection time prevented, indicating improved large arterial compliance. Nitroglycerin reduced supine vascular resistance (−6.7 ± 1.8%) and augmentation index (−7.4 ± 1.6%), and increased cardiac output (+9.2 ± 2.7%). During head-up tilt, nitroglycerin increased cardiac output (+10.6 ± 5.6%) and heart rate (+40 ± 7.5%), decreased vascular resistance (−7.8 ± 5.8%) and augmentation index (−18.7 ± 3.2%), and prevented the decrease in aortic reflection time. CONCLUSIONS Inhaled salbutamol predominantly changed supine haemodynamics, whereas the moderate effects of L-arginine were observed during the head-up tilt. In contrast, small doses of nitroglycerin induced major changes in haemodynamics both supine and during the head-up tilt. Altogether, these results emphasize the importance of haemodynamic measurements in both the supine and upright

  4. A Novel Role for Pro-Coagulant Microvesicles in the Early Host Defense against Streptococcus pyogenes

    PubMed Central

    Oehmcke, Sonja; Westman, Johannes; Malmström, Johan; Mörgelin, Matthias; Olin, Anders I.; Kreikemeyer, Bernd; Herwald, Heiko

    2013-01-01

    Previous studies have shown that stimulation of whole blood or peripheral blood mononuclear cells with bacterial virulence factors results in the sequestration of pro-coagulant microvesicles (MVs). These particles explore their clotting activity via the extrinsic and intrinsic pathway of coagulation; however, their pathophysiological role in infectious diseases remains enigmatic. Here we describe that the interaction of pro-coagulant MVs with bacteria of the species Streptococcus pyogenes is part of the early immune response to the invading pathogen. As shown by negative staining electron microscopy and clotting assays, pro-coagulant MVs bind in the presence of plasma to the bacterial surface. Fibrinogen was identified as a linker that, through binding to the M1 protein of S. pyogenes, allows the opsonization of the bacteria by MVs. Surface plasmon resonance analysis revealed a strong interaction between pro-coagulant MVs and fibrinogen with a KD value in the nanomolar range. When performing a mass-spectrometry-based strategy to determine the protein quantity, a significant up-regulation of the fibrinogen-binding integrins CD18 and CD11b on pro-coagulant MVs was recorded. Finally we show that plasma clots induced by pro-coagulant MVs are able to prevent bacterial dissemination and possess antimicrobial activity. These findings were confirmed by in vivo experiments, as local treatment with pro-coagulant MVs dampens bacterial spreading to other organs and improved survival in an invasive streptococcal mouse model of infection. Taken together, our data implicate that pro-coagulant MVs play an important role in the early response of the innate immune system in infectious diseases. PMID:23935504

  5. Feasibility investigation of oily wastewater treatment by combination of zinc and PAM in coagulation/flocculation.

    PubMed

    Zeng, Yubin; Yang, Changzhu; Zhang, Jingdong; Pu, Wenhong

    2007-08-25

    Poly-zinc silicate (PZSS) is a new type of coagulant with cationic polymer synthesized by polysilicic acid and zinc sulfate. It has been used in several sorts of wastewaters treatment, but not used in oily wastewater treatment. In this study, we investigated the coagulation/flocculation of oil and suspended solids in heavy oil wastewater (HOW) by PZSS and anion polyacrylamide (A-PAM). The properties of PZSS cooperated with A-PAM were compared with PAC and PFS in dosages, PAMs amount, settling time, pH value and flocs morphology. The results showed that PZSS was more efficient than PAC and PFS. Under the optimum experimental conditions of coagulation/flocculation (dosage: 100mg/L, A-PAM dosage: 1.0mg/L, settling time time: 40min and pH 6.5-9.5), more than 99% of oil was removed and suspended solid value less than 5mg/L by using PZSS cooperated with A-PAM, which could satisfy the demands of the pre-treatment process for HOW to be reused in the steam boiler or recycled into the injecting well.

  6. Cardiac autonomic and haemodynamic recovery after a single session of aerobic exercise with and without blood flow restriction in older adults.

    PubMed

    Ferreira, Marina Lívia Venturini; Sardeli, Amanda Veiga; Souza, Giovana Vergínia De; Bonganha, Valéria; Santos, Lucas Do Carmo; Castro, Alex; Cavaglieri, Cláudia Regina; Chacon-Mikahil, Mara Patrícia Traina

    2017-12-01

    This study investigated the autonomic and haemodynamic responses to different aerobic exercise loads, with and without blood flow restriction (BFR). In a crossover study, 21 older adults (8 males and 13 females) completed different aerobic exercise sessions: low load without BFR (LL) (40% VO 2 max ), low load with BFR (LL-BFR) (40% VO 2 max + 50% BFR) and high load without BFR (HL) (70% VO 2 max ). Heart rate variability and haemodynamic responses were recorded during rest and throughout 30 min of recovery. HL reduced R-R interval, the root mean square of successive difference of R-R intervals and high frequency during 30 min of recovery at a greater magnitude compared with LL and LL-BFR. Sympathetic-vagal balance increased the values for HL during 30 min of recovery at a greater magnitude when compared with LL and LL-BFR. Post-exercise haemodynamic showed reduced values of double product at 30 min of recovery compared to rest in LL-BFR, while HL showed higher values compared to rest, LL-BFR and LL. Reduced systolic blood pressure was observed for LL-BFR (30 min) compared to rest. Autonomic and haemodynamic responses indicate lower cardiovascular stress after LL-BFR compared to HL, being this method, besides the functional adaptations, a potential choice to attenuate the cardiovascular stress after exercise in older adults.

  7. Characterization of Natural Organic Matter by FeCl3 Coagulation

    NASA Astrophysics Data System (ADS)

    Cahyonugroho, O. H.; Hidayah, E. N.

    2018-01-01

    Natural organic matter (NOM) is heterogenous mixture of organic compounds that enter the water from various decomposition and metabolic reactions, including animal, plant, domestic and industrial wastes. NOM refers to group of carbon-based compounds that are found in surface water and ground water. The aim of the study is to assess organic matter characteristics in Jagir River as drinking water source and to characterize the organic components that could be removed during coagulation. Coagulation is the common water treatment process can be used to remove NOM with FeCl3 coagulant in various dosage. NOM surrogates, including total organic carbon (TOC), ultraviolet absorbance at 254 nm (UV254) and specific UV absorbance (SUVA) were chosen to assess the organic removal. Results of jar test experiments showed that NOM can be removed about 40% of NOM surrogates with 200 mg/L FeCl3. About 60% removal of total organic fraction, which is mainly humic substances, as detected by size exclusion chromatography (SEC).

  8. A Monte Carlo method for the simulation of coagulation and nucleation based on weighted particles and the concepts of stochastic resolution and merging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kotalczyk, G., E-mail: Gregor.Kotalczyk@uni-due.de; Kruis, F.E.

    Monte Carlo simulations based on weighted simulation particles can solve a variety of population balance problems and allow thus to formulate a solution-framework for many chemical engineering processes. This study presents a novel concept for the calculation of coagulation rates of weighted Monte Carlo particles by introducing a family of transformations to non-weighted Monte Carlo particles. The tuning of the accuracy (named ‘stochastic resolution’ in this paper) of those transformations allows the construction of a constant-number coagulation scheme. Furthermore, a parallel algorithm for the inclusion of newly formed Monte Carlo particles due to nucleation is presented in the scope ofmore » a constant-number scheme: the low-weight merging. This technique is found to create significantly less statistical simulation noise than the conventional technique (named ‘random removal’ in this paper). Both concepts are combined into a single GPU-based simulation method which is validated by comparison with the discrete-sectional simulation technique. Two test models describing a constant-rate nucleation coupled to a simultaneous coagulation in 1) the free-molecular regime or 2) the continuum regime are simulated for this purpose.« less

  9. Micro-electromechanical film bulk acoustic sensor for plasma and whole blood coagulation monitoring.

    PubMed

    Chen, Da; Song, Shuren; Ma, Jilong; Zhang, Zhen; Wang, Peng; Liu, Weihui; Guo, Qiuquan

    2017-05-15

    Monitoring blood coagulation is an important issue in the surgeries and the treatment of cardiovascular diseases. In this work, we reported a novel strategy for the blood coagulation monitoring based on a micro-electromechanical film bulk acoustic resonator. The resonator was excited by a lateral electric field and operated under the shear mode with a frequency of 1.9GHz. According to the apparent step-ladder curves of the frequency response to the change of blood viscoelasticity, the coagulation time (prothrombin time) and the coagulation kinetics were measured with the sample consumption of only 1μl. The procoagulant activity of thromboplastin and the anticoagulant effect of heparin on the blood coagulation process were illustrated exemplarily. The measured prothrombin times showed a good linear correlation with R 2 =0.99969 and a consistency with the coefficient of variation less than 5% compared with the commercial coagulometer. The proposed film bulk acoustic sensor, which has the advantages of small size, light weight, low cost, simple operation and little sample consumption, is a promising device for miniaturized, online and automated analytical system for routine diagnostics of hemostatic status and personal health monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Blood coagulation profiling in patients using optical thromboelastography (OTEG) (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Tripathi, Markandey M.; Tshikudi, Diane M.; Hajjarian, Zeinab; Van Cott, Elizabeth M.; Nadkarni, Seemantini K.

    2016-02-01

    Impaired blood coagulation is often associated with increased postoperative mortality and morbidity in cardiovascular patients. The capability for blood coagulation profiling rapidly at the bedside will enable the timely detection of coagulation defects and open the opportunity for tailoring therapy to correct specific coagulation deficits Optical Thromboelastography (OTEG), is an optical approach to quantify blood coagulation status within minutes using a few drops of whole blood. The goal of the current study is to evaluate the diagnostic accuracy of OTEG for rapid coagulation profiling in patients. In OTEG, temporal laser speckle intensity fluctuations from a drop of clotting blood are measured using a CMOS camera. To quantify coagulation status, the speckle intensity autocorrelation function is measured, the mean square displacement of scattering particles is extracted, and viscoelastic modulus (G), during coagulation is measured via the generalized Stokes-Einstein relation. By quantifying time-resolved changes in G, the coagulation parameters, reaction time (R), clot progression time (K), clot progression rate (Angle), and maximum clot strength (MA) are derived. In this study, the above coagulation parameters were measured using OTEG in 269 patients and compared with standard mechanical Thromboelastography (TEG). Our results showed a strong correlation between OTEG and TEG measurements for all parameters: R-time (R=0.80, p<0.001), clotting time (R=0.78, p<0.001), Angle (R=0.58, p<0.001), and MA (R=0.60, p<0.001). These results demonstrate the unique capability of OTEG for rapid quantification of blood coagulation status to potentially improve clinical capability for identifying impaired coagulation in cardiovascular patients at the point of care.

  11. Coagulation activation in autoimmune bullous diseases

    PubMed Central

    Marzano, A V; Tedeschi, A; Spinelli, D; Fanoni, D; Crosti, C; Cugno, M

    2009-01-01

    The main autoimmune blistering skin disorders are pemphigus vulgaris (PV) and bullous pemphigoid (BP). They differ in the inflammatory infiltrate, which is more intense in BP. Inflammation is known to activate coagulation in several disorders. Local and systemic activation of coagulation was evaluated in BP and PV. We studied 20 BP patients (10 active and 10 remittent), 23 PV patients (13 active and 10 remittent) and 10 healthy subjects. The coagulation markers prothrombin fragment F1+2 and D-dimer were measured by enzyme-immunoassays in plasma. The presence of tissue factor (TF), the main initiator of blood coagulation, was evaluated immunohistochemically in skin specimens from 10 patients with active PV, 10 patients with active BP and 10 controls. Plasma F1+2 and D-dimer levels were significantly high in active BP (P = 0·001), whereas in active PV the levels were normal. During remission, F1+2 and D-dimer plasma levels were normal in both BP and PV. TF immunoreactivity was found in active BP but neither in active PV nor in normal skin. TF reactivity scores were higher in active BP than in controls or active PV (P = 0·0001). No difference in TF scores was found between active PV and controls. BP is associated with coagulation activation, which is lacking in PV. This suggests that BP but not PV patients have an increased thrombotic risk. The observation that thrombotic complications occur more frequently in BP than in PV further supports this view. PMID:19737228

  12. Characterization of water treatment sludge and its reuse as coagulant.

    PubMed

    Ahmad, Tarique; Ahmad, Kafeel; Ahad, Abdul; Alam, Mehtab

    2016-11-01

    Coagulation-flocculation process results in the generation of large volume of waste or residue, known as water treatment sludge (WTS), in the purification of surface water for potable supplies. Sustainable management of the inevitable waste requires careful attention from the plant operators and sludge managers. In this study, WTS produced with the optimum alum dose of 30 ml/L at the laboratory scale has been treated with sulphuric acid to bring forth a product known as sludge reagent product (SRP). The performance of SRP is evaluated for its efficiency in removing the colloidal suspensions from the Yamuna river water over wide pH range of 2-13. 1% sludge acidified with sulphuric acid of normality 2.5 at the rate of 0.05 ml/ml sludge has been observed as the optimum condition for preparing SRP from WTS. The percentage turbidity removal is greater at higher pH value and increases with increasing the dosage of SRP. The optimum SRP dosage of 8 ml/L in the pH range of 6-8 performed well in removing the colloidal suspension and other impurities from the Yamuna water. The quality of treated water met the prescribed standards for most of the quality parameters. Thus, SRP has the potential to substitute the conventional coagulants partially or completely in the water treatment process, depending on the quality needed at the users end. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Treatment of waste water by coagulation and flocculation using biomaterials

    NASA Astrophysics Data System (ADS)

    Muruganandam, L.; Saravana Kumar, M. P.; Jena, Amarjit; Gulla, Sudiv; Godhwani, Bhagesh

    2017-11-01

    The present study deals with the determination of physical and chemical parameters in the treatment process of waste water by flocculation and coagulation processes using natural coagulants and assessing their feasibility for water treatment by comparing the performance with each other and with a synthetic coagulant. Initial studies were done on the synthetic waste water to determine the optimal pH and dosage, the activity of natural coagulant, followed by the real effluent from tannery waste. The raw tannery effluent was bluish-black in colour, mildly basic in nature, with high COD 4000mg/l and turbidity in the range 700NTU, was diluted and dosed with organic coagulants, AloeVera, MoringaOleifera and Cactus (O.ficus-indica). The study observed that coagulant Moringa Oleifera of 15 mg/L dose at 6 pH gave the best reduction efficiencies for major physicochemical parameters followed by Aloe Vera and Cactus under identical conditions. The study reveals that the untreated tannery effluents can be treated with environmental confirmative naturally occurring coagulants.

  14. Genetic parameters for milk coagulation properties in Estonian Holstein cows.

    PubMed

    Vallas, M; Bovenhuis, H; Kaart, T; Pärna, K; Kiiman, H; Pärna, E

    2010-08-01

    The objective of this study was to estimate heritabilities and repeatabilities for milk coagulation traits [milk coagulation time (RCT) and curd firmness (E(30))] and genetic and phenotypic correlations between milk yield and composition traits (milk fat percentage and protein percentage, urea, somatic cell count, pH) in first-lactation Estonian Holstein dairy cattle. A total of 17,577 test-day records from 4,191 Estonian Holstein cows in 73 herds across the country were collected during routine milk recordings. Measurements of RCT and E(30) determined with the Optigraph (Ysebaert, Frepillon, France) are based on an optical signal in the near-infrared region. The cows had at least 3 measurements taken during the period from April 2005 to January 2009. Data were analyzed using a repeatability animal model. There was substantial variation in milk coagulation traits with a coefficient of variation of 27% for E(30) and 9% for the log-transformed RCT. The percentage of variation explained by herd was 3% for E(30) and 4% for RCT, suggesting that milk coagulation traits are not strongly affected by herd conditions (e.g., feeding). Heritability was 0.28 for RCT and 0.41 for E(30), and repeatability estimates were 0.45 and 0.50, respectively. Genetic correlation between both milk coagulation traits was negligible, suggesting that RCT and E(30) have genetically different foundations. Milk coagulation time had a moderately high positive genetic (0.69) and phenotypic (0.61) correlation with milk pH indicating that a high pH is related to a less favorable RCT. Curd firmness had a moderate positive genetic (0.48) and phenotypic (0.45) correlation with the protein percentage. Therefore, a high protein percentage is associated with favorable curd firmness. All reported genetic parameters were statistically significantly different from zero. Additional univariate random regression analysis for milk coagulation traits yielded slightly higher average heritabilities of 0.38 and 0

  15. Coagulation dynamics of a blood sample by multiple scattering analysis

    NASA Astrophysics Data System (ADS)

    Faivre, Magalie; Peltié, Philippe; Planat-Chrétien, Anne; Cosnier, Marie-Line; Cubizolles, Myriam; Nougier, Christophe; Négrier, Claude; Pouteau, Patrick

    2011-05-01

    We report a new technique to measure coagulation dynamics on whole-blood samples. The method relies on the analysis of the speckle figure resulting from a whole-blood sample mixed with coagulation reagent and introduced in a thin chamber illuminated with a coherent light. A dynamic study of the speckle reveals a typical behavior due to coagulation. We compare our measured coagulation times to a reference method obtained in a medical laboratory.

  16. Nanoparticle coagulation in fractionally charged and charge fluctuating dusty plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nunomura, Shota; Kondo, Michio; Shiratani, Masaharu

    2008-08-15

    The kinetics of nanoparticle coagulation has been studied in fractionally charged and charge fluctuating dusty plasmas. The coagulation occurs when the mutual collision frequency among nanoparticles exceeds their charging and decharging/neutralization frequency. Interestingly, the coagulation is suppressed while a fraction (several percent) of nanoparticles are negatively charged in a plasma, in which stochastic charging plays an important role. A model is developed to predict a phase diagram of the coagulation and its suppression.

  17. Optical coherence tomography-guided laser microsurgery for blood coagulation with continuous-wave laser diode.

    PubMed

    Chang, Feng-Yu; Tsai, Meng-Tsan; Wang, Zu-Yi; Chi, Chun-Kai; Lee, Cheng-Kuang; Yang, Chih-Hsun; Chan, Ming-Che; Lee, Ya-Ju

    2015-11-16

    Blood coagulation is the clotting and subsequent dissolution of the clot following repair to the damaged tissue. However, inducing blood coagulation is difficult for some patients with homeostasis dysfunction or during surgery. In this study, we proposed a method to develop an integrated system that combines optical coherence tomography (OCT) and laser microsurgery for blood coagulation. Also, an algorithm for positioning of the treatment location from OCT images was developed. With OCT scanning, 2D/3D OCT images and angiography of tissue can be obtained simultaneously, enabling to noninvasively reconstruct the morphological and microvascular structures for real-time monitoring of changes in biological tissues during laser microsurgery. Instead of high-cost pulsed lasers, continuous-wave laser diodes (CW-LDs) with the central wavelengths of 450 nm and 532 nm are used for blood coagulation, corresponding to higher absorption coefficients of oxyhemoglobin and deoxyhemoglobin. Experimental results showed that the location of laser exposure can be accurately controlled with the proposed approach of imaging-based feedback positioning. Moreover, blood coagulation can be efficiently induced by CW-LDs and the coagulation process can be monitored in real-time with OCT. This technology enables to potentially provide accurate positioning for laser microsurgery and control the laser exposure to avoid extra damage by real-time OCT imaging.

  18. Optical coherence tomography-guided laser microsurgery for blood coagulation with continuous-wave laser diode

    NASA Astrophysics Data System (ADS)

    Chang, Feng-Yu; Tsai, Meng-Tsan; Wang, Zu-Yi; Chi, Chun-Kai; Lee, Cheng-Kuang; Yang, Chih-Hsun; Chan, Ming-Che; Lee, Ya-Ju

    2015-11-01

    Blood coagulation is the clotting and subsequent dissolution of the clot following repair to the damaged tissue. However, inducing blood coagulation is difficult for some patients with homeostasis dysfunction or during surgery. In this study, we proposed a method to develop an integrated system that combines optical coherence tomography (OCT) and laser microsurgery for blood coagulation. Also, an algorithm for positioning of the treatment location from OCT images was developed. With OCT scanning, 2D/3D OCT images and angiography of tissue can be obtained simultaneously, enabling to noninvasively reconstruct the morphological and microvascular structures for real-time monitoring of changes in biological tissues during laser microsurgery. Instead of high-cost pulsed lasers, continuous-wave laser diodes (CW-LDs) with the central wavelengths of 450 nm and 532 nm are used for blood coagulation, corresponding to higher absorption coefficients of oxyhemoglobin and deoxyhemoglobin. Experimental results showed that the location of laser exposure can be accurately controlled with the proposed approach of imaging-based feedback positioning. Moreover, blood coagulation can be efficiently induced by CW-LDs and the coagulation process can be monitored in real-time with OCT. This technology enables to potentially provide accurate positioning for laser microsurgery and control the laser exposure to avoid extra damage by real-time OCT imaging.

  19. Competition of coagulation sink and source rate: New particle formation in the Pearl River Delta of China

    NASA Astrophysics Data System (ADS)

    Gong, Youguo; Hu, Min; Cheng, Yafang; Su, Hang; Yue, Dingli; Liu, Feng; Wiedensohler, A.; Wang, Zhibin; Kalesse, H.; Liu, Shang; Wu, Zhijun; Xiao, Kaitao; Mi, Puchun; Zhang, Yuanhang

    The coagulation sink and its role in new particle formation are investigated based on data obtained during the PRIDE-PRD2004 campaign at Xinken of Pearl River Delta, China. Analysis of size distributions and mode contributions of the coagulation sink show that the observed higher load of accumulation mode particles impose a significant effect on the coagulation sink and result in higher coagulation sinks at Xinken despite of the lower total particle number compared with other areas. Hence it is concluded that the higher coagulation sink may depress the occurrence frequency of new particle formation events. The strategies targeting at controlling accumulation mode particles may have influences on the frequency of new particle formation events at this area. The factors affecting the coagulation sink are evaluated. The relatively lower ambient relative humidities may weaken the coagulation sink and facilitate the occurrence of new particle formation events during noontime, while the surmise of nucleation and growth involving organic matter may imply an actually higher coagulation sink than expected. These factors have a significant influence on the ultimate fate of the newly formed nuclei and new particle formation. A comparison of event and non-event days indicates that the coagulation sink is not the only decisive factor affecting new particle formation, other factors including the precursor vapors and photochemical activity are none the less important either. Competition of coagulation sink and high source rate leads to the occurrence of new particle formation events at Xinken.

  20. Weighted Flow Algorithms (WFA) for stochastic particle coagulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeVille, R.E.L., E-mail: rdeville@illinois.edu; Riemer, N., E-mail: nriemer@illinois.edu; West, M., E-mail: mwest@illinois.edu

    2011-09-20

    Stochastic particle-resolved methods are a useful way to compute the time evolution of the multi-dimensional size distribution of atmospheric aerosol particles. An effective approach to improve the efficiency of such models is the use of weighted computational particles. Here we introduce particle weighting functions that are power laws in particle size to the recently-developed particle-resolved model PartMC-MOSAIC and present the mathematical formalism of these Weighted Flow Algorithms (WFA) for particle coagulation and growth. We apply this to an urban plume scenario that simulates a particle population undergoing emission of different particle types, dilution, coagulation and aerosol chemistry along a Lagrangianmore » trajectory. We quantify the performance of the Weighted Flow Algorithm for number and mass-based quantities of relevance for atmospheric sciences applications.« less

  1. Weighted Flow Algorithms (WFA) for stochastic particle coagulation

    NASA Astrophysics Data System (ADS)

    DeVille, R. E. L.; Riemer, N.; West, M.

    2011-09-01

    Stochastic particle-resolved methods are a useful way to compute the time evolution of the multi-dimensional size distribution of atmospheric aerosol particles. An effective approach to improve the efficiency of such models is the use of weighted computational particles. Here we introduce particle weighting functions that are power laws in particle size to the recently-developed particle-resolved model PartMC-MOSAIC and present the mathematical formalism of these Weighted Flow Algorithms (WFA) for particle coagulation and growth. We apply this to an urban plume scenario that simulates a particle population undergoing emission of different particle types, dilution, coagulation and aerosol chemistry along a Lagrangian trajectory. We quantify the performance of the Weighted Flow Algorithm for number and mass-based quantities of relevance for atmospheric sciences applications.

  2. Upregulation of the Coagulation Factor VII Gene during Glucose Deprivation Is Mediated by Activating Transcription Factor 4

    PubMed Central

    Cronin, Katherine R.; Mangan, Thomas P.; Carew, Josephine A.

    2012-01-01

    Background Constitutive production of blood coagulation proteins by hepatocytes is necessary for hemostasis. Stressful conditions trigger adaptive cellular responses and delay processing of most proteins, potentially affecting plasma levels of proteins secreted exclusively by hepatocytes. We examined the effect of glucose deprivation on expression of coagulation proteins by the human hepatoma cell line, HepG2. Methodology/Principal Findings Expression of coagulation factor VII, which is required for initiation of blood coagulation, was elevated by glucose deprivation, while expression of other coagulation proteins decreased. Realtime PCR and ELISA demonstrated that the relative percentage expression +/− SD of steady-state F7 mRNA and secreted factor VII antigen were significantly increased (from 100+/−15% to 188+/−27% and 100+/−8.8% to 176.3+/−17.3% respectively, p<0.001) at 24 hr of treatment. The integrated stress response was induced, as indicated by upregulation of transcription factor ATF4 and of additional stress-responsive genes. Small interfering RNAs directed against ATF4 potently reduced basal F7 expression, and prevented F7 upregulation by glucose deprivation. The response of the endogenous F7 gene was replicated in reporter gene assays, which further indicated that ATF4 effects were mediated via interaction with an amino acid response element in the F7 promoter. Conclusions/Significance Our data indicated that glucose deprivation enhanced F7 expression in a mechanism reliant on prior ATF4 upregulation primarily due to increased transcription from the ATF4 gene. Of five coagulation protein genes examined, only F7 was upregulated, suggesting that its functions may be important in a systemic response to glucose deprivation stress. PMID:22848420

  3. Removal and transformation of effluent organic matter (EfOM) in biotreated textile wastewater by GAC/O3 pre-oxidation and enhanced coagulation.

    PubMed

    Qian, Feiyue; Sun, Xianbo; Liu, Yongdi; Xu, Hongyong

    2013-01-01

    GAC/O3 (ozonation in the presence of granular activated carbon) combined with enhanced coagulation was employed to process biotreated textile wastewater for possible reuse. The doses of ozone, GAC and coagulant were the variables studied for optimization. The effects of different treatment processes on effluent organic matter (EfOM) characteristics, including biodegradability, hydrophobic and hydrophilic nature, and apparent molecular weight (AMW) distribution were also investigated. Compared with ozonation, GAC/O3 not only presented a higher pre-oxidation efficiency, but also improved the treatability of hydrophobic and high molecular weight compounds by enhanced coagulation. After treatment by GAC/O3 pre-oxidation (0.6 mg O3 x mg(-1) COD and 20 g x L(-1) GAC) and enhanced coagulation (25 mg x L(-1) Al3+ at pH 5.5), the removal efficiencies of chemical oxygen demand (COD), dissolved organic carbon (DOC) and colour were higher than those for coagulation alone by 17.3%, 12.0% and 25.6%, respectively. Residual organic matter consisted mainly of hydrophobic acids and hydrophilic compounds of AMW < 1 kDa, which were colourless and of limited biological availability. The combination of GAC/O3 and enhanced coagulation was proved to be a simple and effective treatment strategy for removing EfOM from biotreated textile wastewater.

  4. Monopolar soft-mode coagulation using hemostatic forceps for peptic ulcer bleeding.

    PubMed

    Yamasaki, Yasushi; Takenaka, Ryuta; Nunoue, Tomokazu; Kono, Yoshiyasu; Takemoto, Koji; Taira, Akihiko; Tsugeno, Hirofumi; Fujiki, Shigeatsu

    2014-01-01

    Upper gastrointestinal hemorrhage from bleeding peptic ulcer is sometimes difficult to treat by conventional endoscopic methods. Recently, monopolar electrocoagulation using a soft-coagulation system and hemostatic forceps (soft coagulation) has been used to prevent bleeding during endoscopic submucosal dissection. The aim of this study was to assess the safety and efficacy of soft coagulation in the treatment of bleeding peptic ulcer. A total of 39 patients with peptic ulcers were treated using soft coagulation at our hospital between January 2005 and March 2010. Emergency treatment employed an ERBE soft-mode coagulation system using hemostatic forceps. Second-look endoscopy was performed to evaluate the efficacy of prior therapy. Initial hemostasis was defined as accomplished by soft coagulation, with or without other endoscopic therapy prior to soft coagulation. The rate of initial hemostasis, rebleeding, and ultimate hemostasis were retrospectively analyzed. The study subjects were 31 men and 8 women with a mean age of 68.3±13.7 years, with 29 gastric ulcers and 10 duodenal ulcers. Initial hemostasis was achieved in 37 patients (95%). During follow-up, bleeding recurred in two patients, who were retreated with soft coagulation. The monopolar soft coagulation is feasible and safe for treating bleeding peptic ulcers.

  5. Elastic scattering spectroscopy of coagulated brain tissues

    NASA Astrophysics Data System (ADS)

    Ateş, Filiz; Tabakoğlu, Haşim Özgür; Bozkulak, Özgüncem; Canpolat, Murat; Gülsoy, Murat

    2006-02-01

    The goal of this study was to differentiate the parts of lamb brain according to elastic scattering spectroscopy and detect the optical alterations due to coagulation. Cells and tissues are not uniform and have complex structures and shapes. They can be referred to as scattering particles. The process of scattering depends on the light wavelength and on the scattering medium properties; especially on the size and the density of the medium. When elastic scattering spectroscopy (ESS) is employed, the morphological alterations of tissues can be detected using spectral measurements of the elastic scattered light over a wide range of wavelengths. In this study firstly, the slopes of ESS spectra were used to differentiate the parts of lamb brains (brainstem, cerebellum, gray matter, white matter) in vitro in the range of 450 - 750 nm. Secondly, tissues were coagulated at different temperatures (45, 60, and 80 °C) and ESS spectra were taken from native and coagulated tissues. It was observed that as the coagulation temperature increased, the slope of the elastic scattering spectra decreased. Thus, optical properties of tissues were changed with respect to the change in nuclear to cytoplasmic ratio due to the water loss. Results showed that the slopes of ESS spectra in the visible range revealed valuable information about the morphological changes caused by coagulation.

  6. Administration of tissue plasminogen activator without coagulation results in a Chinese population.

    PubMed

    Qin, Xiaoming; Zhao, Songyao; Yin, Liujie; Dou, Hailing; Chen, Jie; Wang, Yifan; Li, Mingzhe; Chen, Ruifang; Fu, Jing; Liu, Wei; Liu, Xin; Yang, Gaiqing; Wang, Runqing; Jia, Xinzhou; Bu, Shufang; Ma, Dongpu; Wang, Baoyu; Li, Shize

    2018-03-01

    Routine coagulation test before intravenous tissue plasminogen activator (tPA) use increases the door to needle time (DNT). We sought to evaluate the safety of tPA use without coagulation results and its impact on prognosis. In our stroke registry, tPA was delivered with coagulation results from December 2015 to April 2016 and without coagulation results from May 2016 to December 2016. Differences of demographics, clinical characteristic, and prognosis between these two groups were analyzed. In addition, logistic regression analysis was conducted to identify predictors for DNT of over 60 min. A total of 201 stroke patients were included in the final analysis. Of these, 81 patients received tPA with coagulation results and 120 patients without coagulation results. Only one (0.8%) patient with abnormal coagulation results met the exclusion criteria of tPA use in patients without coagulation results. The difference of DNT between groups with (mean, 61.7 min) and without (mean, 41.9 min) coagulation results was significant (P = 0.00). The group without coagulation results had a higher rate of favorable 90-day outcome (74.2 vs 70.4%) and lower rates of symptomatic intracranial hemorrhage/nonintracranial hemorrhage (4.9 and 22.2% vs 1.7 and 19.2%) than the group with coagulation results did; these differences were not statistically significant. In multivariate analysis, only tPA use with coagulation results was the predictor for DNT of over 60 min (P = 0.0030, OR = 2.44, 95% CI 1.28-4.65). The present study suggests that tPA could be delivered safely without coagulation results in patients without suspected coagulopathy, and avoiding coagulation tests reduces significantly the DNT interval.

  7. Coagulation cascade and complement system in systemic lupus erythematosus

    PubMed Central

    Liang, Yan; Xie, Shang-Bo; Wu, Chang-Hao; Hu, Yuan; Zhang, Qin; Li, Si; Fan, Yin-Guang; Leng, Rui-Xue; Pan, Hai-Feng; Xiong, Hua-Bao; Ye, Dong-Qing

    2018-01-01

    This study was conducted to (1) characterize coagulation cascade and complement system in systemic lupus erythematosus (SLE); (2) evaluate the associations between coagulation cascade, complement system, inflammatory response and SLE disease severity; (3) test the diagnostic value of a combination of D-dimer and C4 for lupus activity. Transcriptomics, proteomics and metabolomics were performed in 24 SLE patients and 24 healthy controls. The levels of ten coagulations, seven complements and three cytokines were measured in 112 SLE patients. Clinical data were collected from 2025 SLE patients. The analysis of multi-omics data revealed the common links for the components of coagulation cascade and complement system. The results of ELISA showed coagulation cascade and complement system had an interaction effect on SLE disease severity, this effect was pronounced among patients with excess inflammation. The analysis of clinical data revealed a combination of D-dimer and C4 provided good diagnostic performance for lupus activity. This study suggested that coagulation cascade and complement system become ‘partners in crime’, contributing to SLE disease severity and identified the diagnostic value of D-dimer combined with C4for lupus activity. PMID:29599912

  8. Effects of low temperature on coagulation of kaolinite suspensions.

    PubMed

    Xiao, Feng; Ma, Jun; Yi, Peng; Huang, Ju-Chang Howard

    2008-06-01

    In this study, coagulation of kaolinite suspensions at low temperatures is compared with that at an ambient temperature of 22 degrees C, and the process is examined with regard to the coagulation rate (CR) and chemical aspects of coagulation. Experiments using a photometric dispersion analyzer (PDA) show that coagulation of kaolinite suspensions can be taken as a two-phase process. Low temperature greatly reduces the CR of the first phase but not that of the second one. On the other hand, results show that low temperature did not serve to impede the hydrolysis of aluminum [Al(III)] within 1 min of alum addition. The measurements of electrophoretic mobility (EM) indicate that destabilization of kaolinite particles by hydrolyzed Al species was not hindered by low temperature within 1 min of alum addition. Slow coagulation at low temperature is due to the lowered CR but not the altered chemistry aspect of Al(III). Furthermore, the change in settled turbidity after 20-min flocculation as a function of coagulant dosage was more severe in the cold because of the low CR. Elongating floc-growth time, as observed, was able to counterbalance the retarded CR at low temperature and improve turbidity removal efficiency.

  9. Performance of ultrafiltration membrane process combined with coagulation/sedimentation.

    PubMed

    Jang, N Y; Watanabe, Y; Minegishi, S

    2005-01-01

    Effects of coagulation/sedimentation as a pre-treatment on the dead-end ultrafiltration (UF) membrane process were studied in terms of membrane fouling and removal efficiency of natural dissolved organic matter, using Chitose River water. Two types of experiment were carried out. One was a bench scale membrane filtration with jar-test and the other was membrane filtration pilot plant combined with the Jet Mixed Separator (JMS) as a pre-coagulation/sedimentation unit. In the bench scale experiment, the effects of coagulant dosage, pH and membrane operating pressure on the membrane fouling and removal efficiency of natural dissolved organic matter were investigated. In the pilot plant experiment, we also investigated the effect of pre-coagulation/sedimentation on the membrane fouling and the removal efficiency of natural dissolved organic matter. Coagulation/sedimentation prior to membrane filtration process controlled the membrane fouling and increased the removal efficiency of natural dissolved organic matter.

  10. Amiodarone. Haemodynamic profile during intravenous administration and effect on pacing-induced ischaemia in man.

    PubMed

    Remme, W J; van Hoogenhuyze, D C; Kruyssen, D A; Krauss, X H; Storm, C J

    1985-03-01

    -ischaemic properties are mainly based on a reduction of myocardial oxygen demand, rather than on an improvement in coronary flow. It is concluded then, that amiodarone has significant haemodynamic effects as manifested by an early reduction in vascular resistance and a late negative inotropic effect. Although vasodilatation of short duration caused by its solvent, polysorbate 80, also occurs, the overall cardiovascular changes are caused by the direct, intrinsic haemodynamic effects of amiodarone alone. The important anti-ischaemic properties of amiodarone appear to result primarily from these cardiovascular actions and the inherent reduction in myocardial oxygen demand.

  11. Nanoparticles and the blood coagulation system. Part II: safety concerns

    PubMed Central

    Ilinskaya, Anna N; Dobrovolskaia, Marina A

    2014-01-01

    Nanoparticle interactions with the blood coagulation system can be beneficial or adverse depending on the intended use of a nanomaterial. Nanoparticles can be engineered to be procoagulant or to carry coagulation-initiating factors to treat certain disorders. Likewise, they can be designed to be anticoagulant or to carry anticoagulant drugs to intervene in other pathological conditions in which coagulation is a concern. An overview of the coagulation system was given and a discussion of a desirable interface between this system and engineered nanomaterials was assessed in part I, which was published in the May 2013 issue of Nanomedicine. Unwanted pro- and anti-coagulant properties of nanoparticles represent significant concerns in the field of nanomedicine, and often hamper the development and transition into the clinic of many promising engineered nanocarriers. This part will focus on the undesirable effects of engineered nanomaterials on the blood coagulation system. We will discuss the relationship between the physicochemical properties of nanoparticles (e.g., size, charge and hydrophobicity) that determine their negative effects on the blood coagulation system in order to understand how manipulation of these properties can help to overcome unwanted side effects. PMID:23730696

  12. The effect of low molecular weight dextran on haemodynamics and respiratory function during endotoxin-induced shock.

    PubMed Central

    Christenson, J T; al-Sarraf, A; Abu-Saleh, R

    1992-01-01

    The effects of low molecular weight dextran (LMWD) infusion, on gas exchange and haemodynamics were evaluated in sheep during endotoxin shock. The infusion of LMWD was started after signs of shock and lung injury were evident. After a stabilization period 10 micrograms kg-1 E. Coli endotoxin was infused i.v.. Endotoxin infusion resulted in an marked increase in pulmonary artery pressure (PAP) and decrease in mean arterial pressure (MAP), respiratory compliance, arterial oxygen tension (PaO2) and oxygen delivery index (DO2l). After 3 h MAP, PaO2, DO2l and compliance improved significantly in LMWD treated animals. The PAP had also decreased significantly in the LMWD-treated animals, but remained high in the controls (P less than 0.01). It was concluded that LMWD infusion improves haemodynamics and gas-exchange in sheep during endotoxin shock. PMID:1373624

  13. Promyelocytic extracellular chromatin exacerbates coagulation and fibrinolysis in acute promyelocytic leukemia

    PubMed Central

    Cao, Muhua; Li, Tao; He, Zhangxiu; Wang, Lixiu; Yang, Xiaoyan; Kou, Yan; Zou, Lili; Dong, Xue; Novakovic, Valerie A.; Bi, Yayan; Kou, Junjie; Yu, Bo; Fang, Shaohong; Wang, Jinghua; Zhou, Jin

    2017-01-01

    Despite routine treatment of unselected acute promyelocytic leukemia (APL) with all-trans-retinoic acid (ATRA), early death because of hemorrhage remains unacceptably common, and the mechanism underlying this complication remains elusive. We have recently demonstrated that APL cells undergo a novel cell death program, termed ETosis, which involves release of extracellular chromatin. However, the role of promyelocytic extracellular chromatin in APL-associated coagulation remains unclear. Our objectives were to identify the novel role of ATRA-promoted extracellular chromatin in inducing a hypercoagulable and hyperfibrinolytic state in APL and to evaluate its interaction with fibrin and endothelial cells (ECs). Results from a series of coagulation assays have shown that promyelocytic extracellular chromatin increases thrombin and plasmin generation, causes a shortening of plasma clotting time of APL cells, and increases fibrin formation. DNase I but not anti-tissue factor antibody could inhibit these effects. Immunofluorescence staining showed that promyelocytic extracellular chromatin and phosphatidylserine on APL cells provide platforms for fibrin deposition and render clots more resistant to fibrinolysis. Additionally, coincubation assays revealed that promyelocytic extracellular chromatin is cytotoxic to ECs, converting them to a procoagulant phenotype. This cytotoxity was blocked by DNase I by 20% or activated protein C by 31%. Our current results thus delineate the pathogenic role of promyelocytic extracellular chromatin in APL coagulopathy. Furthermore, the remaining coagulation disturbance in high-risk APL patients after ATRA administration may be treatable by intrinsic pathway inhibition via accelerating extracellular chromatin degradation. PMID:28053193

  14. Does whole blood coagulation analysis reflect developmental haemostasis?

    PubMed

    Ravn, Hanne Berg; Andreasen, Jo Bønding; Hvas, Anne-Mette

    2017-04-01

    : Developmental haemostasis has been well documented over the last 3 decades and age-dependent reference ranges have been reported for a number of plasmatic coagulation parameters. With the increasing use of whole blood point-of-care tests like rotational thromboelastometry (ROTEM) and platelet function tests, an evaluation of age-dependent changes is warranted for these tests as well. We obtained blood samples from 149 children, aged 1 day to 5.9 years, and analysed conventional plasmatic coagulation tests, including activated partial prothrombin time, prothrombin time, and fibrinogen (functional). Whole blood samples were analysed using ROTEM to assess overall coagulation capacity and Multiplate analyzer to evaluate platelet aggregation. Age-dependent changes were analysed for all variables. We found age-dependent differences in all conventional coagulation tests (all P values < 0.05), but there was no sign of developmental changes in whole blood coagulation assessment when applying ROTEM, apart from clotting time in the EXTEM assay (P < 0.03). Despite marked differences in mean platelet aggregation between age groups, data did not reach statistical significance. Citrate-anticoagulated blood showed significantly reduced platelet aggregation compared with blood anticoagulated with heparin or hirudin (all P values < 0.003). We confirmed previous developmental changes in conventional plasmatic coagulation test. However, these age-dependent changes were not displayed in whole blood monitoring using ROTEM or Multiplate analyzer. Type of anticoagulant had a significant influence on platelet aggregation across all age groups.

  15. Coagulation mechanism of salt solution-extracted active component in Moringa oleifera seeds.

    PubMed

    Okuda, T; Baes, A U; Nishijima, W; Okada, M

    2001-03-01

    This study focuses on the coagulation mechanism by the purified coagulant solution (MOC-SC-PC) with the coagulation active component extracted from M. oleifera seeds using salt solution. The addition of MOC-SC-PC tap water formed insoluble matters. This formation was responsible for kaolin coagulation. On the other hand, insoluble matters were not formed when the MOC-SC-PC was added into distilled water. The formation was affected by Ca2+ or other bivalent cations which may connect each molecule of the active coagulation component in MOC-SC-PC and form a net-like structure. The coagulation mechanism of MOC-SC-PC seemed to be an enmeshment of Kaolin by the insoluble matters with the net-like structure. In case of Ca2+ ion (bivalent cations), at least 0.2 mM was necessary for coagulation at 0.3 mgC l-1 dose of MOC-SC-PC. Other coagulation mechanisms like compression of double layer, interparticle bridging or charge neutralization were not responsible for the coagulation by MOC-SC-PC.

  16. Effects of active recovery on autonomic and haemodynamic responses after aerobic exercise.

    PubMed

    Soares, Antonio H G; Oliveira, Tiago P; Cavalcante, Bruno R; Farah, Breno Q; Lima, Aluísio H R A; Cucato, Gabriel G; Cardoso, Crivaldo G; Ritti-Dias, Raphael M

    2017-01-01

    The aim of this study was to examine the effect of active recovery on autonomic and haemodynamic responses after exercise in healthy adults. Nineteen healthy young male individuals underwent two experimental sessions: exercise with active recovery (AR) and exercise with passive recovery (PR). The exercise sessions comprised three phases: warm-up (5 min), exercise phase (cycle ergometer, 30 min, intensity between 60 and 70% of the heart rate reserve) and recovery (5 min). In the AR, the subjects remained cycling in the recovery phase at intensity between 30% and 35% of heart rate reserve, while in the PR, the subjects stopped the exercise after finishing the exercise phase. Blood pressure and heart rate were measured before and over the 30 min after the interventions. There were no differences for systolic and diastolic blood pressures, heart rate and rate pressure product between active and passive recovery sessions. Also, all heart rate variability parameters changed similarly after exercise with passive or active recovery sessions. In summary, exercise with active recovery does not affect the autonomic and haemodynamic responses after moderate-intensity aerobic exercise in healthy young male individuals. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  17. NOTE: Haemodynamic resistance model of monochorionic twin pregnancies complicated by acardiac twinning

    NASA Astrophysics Data System (ADS)

    Umur, Asli; van Gemert, Martin J. C.; van den Wijngaard, Jeroen P. H. M.; Ross, Michael G.; Nikkels, Peter G. J.

    2004-07-01

    An acardiac twin is a severely malformed monochorionic twin fetus that lacks most organs, particularly a heart. It grows during pregnancy, because it is perfused by its developmentally normal co-twin (called the pump twin) via a set of placental arterioarterial and venovenous anastomoses. The pump twin dies intrauterine or neonatally in about 50% of the cases due to congestive heart failure, polyhydramnios and prematurity. Because the pathophysiology of this pregnancy is currently incompletely understood, we modified our previous haemodynamic model of monochorionic twins connected by placental vascular anastomoses to include the analysis of acardiac twin pregnancies. We incorporated the fetoplacental circulation as a resistance circuit and used the fetal umbilical flow that perfuses the body to define fetal growth, rather than the placental flow as done previously. Using this modified model, we predicted that the pump twin has excess blood volume and increased mean arterial blood pressure compared to those in the acardiac twin. Placental perfusion of the acardiac twin is significantly reduced compared to normal, as a consequence of an increased venous pressure, possibly implying reduced acardiac placental growth. In conclusion, the haemodynamic analysis may contribute to an increased knowledge of the pathophysiologic consequences of an acardiac body mass for the pump twin.

  18. Micro- and mesoscopic process interactions in protein coagulation

    NASA Astrophysics Data System (ADS)

    San Biagio, P. L.; Martorana, V.; Emanuele, A.; Vaiana, S. M.; Manno, M.; Bulone, D.; Palma-Vittorelli, M. B.; Palma, M. U.

    2000-04-01

    It has recently been recognized that pathological protein coagulation is responsible for lethal pathologies as diverse as amyloidosis, Alzheimer and TSE. Understanding the coagulation mechanisms is therefore stirring great interest. In previous studies we have shown that on profoundly different systems coagulation is the result of a strong interaction between two processes on different length scales (mesoscopic and microscopic). Here we report experiments on bovine serum albumin (BSA) showing that the overall mechanism is the result of at least 3 distinct and strongly intertwined processes, on both length scales: molecular conformational changes, solution demixing and intermolecular crosslinking. This mechanism involves the statistical mechanics of protein-solvent interaction, its relation to the protein's landscape of configurational free energy and to the solution's thermodynamic stability, and its relation to the topological problem of crosslink-percolation, responsible for coagulation.

  19. Genetic Factors Influencing Coagulation Factor XIII B-Subunit Contribute to Risk of Ischemic Stroke.

    PubMed

    Hanscombe, Ken B; Traylor, Matthew; Hysi, Pirro G; Bevan, Stephen; Dichgans, Martin; Rothwell, Peter M; Worrall, Bradford B; Seshadri, Sudha; Sudlow, Cathie; Williams, Frances M K; Markus, Hugh S; Lewis, Cathryn M

    2015-08-01

    Abnormal coagulation has been implicated in the pathogenesis of ischemic stroke, but how this association is mediated and whether it differs between ischemic stroke subtypes is unknown. We determined the shared genetic risk between 14 coagulation factors and ischemic stroke and its subtypes. Using genome-wide association study results for 14 coagulation factors from the population-based TwinsUK sample (N≈2000 for each factor), meta-analysis results from the METASTROKE consortium ischemic stroke genome-wide association study (12 389 cases, 62 004 controls), and genotype data for 9520 individuals from the WTCCC2 ischemic stroke study (3548 cases, 5972 controls-the largest METASTROKE subsample), we explored shared genetic risk for coagulation and stroke. We performed three analyses: (1) a test for excess concordance (or discordance) in single nucleotide polymorphism effect direction across coagulation and stroke, (2) an estimation of the joint effect of multiple coagulation-associated single nucleotide polymorphisms in stroke, and (3) an evaluation of common genetic risk between coagulation and stroke. One coagulation factor, factor XIII subunit B (FXIIIB), showed consistent effects in the concordance analysis, the estimation of polygenic risk, and the validation with genotype data, with associations specific to the cardioembolic stroke subtype. Effect directions for FXIIIB-associated single nucleotide polymorphisms were significantly discordant with cardioembolic disease (smallest P=5.7×10(-04)); the joint effect of FXIIIB-associated single nucleotide polymorphisms was significantly predictive of ischemic stroke (smallest P=1.8×10(-04)) and the cardioembolic subtype (smallest P=1.7×10(-04)). We found substantial negative genetic covariation between FXIIIB and ischemic stroke (rG=-0.71, P=0.01) and the cardioembolic subtype (rG=-0.80, P=0.03). Genetic markers associated with low FXIIIB levels increase risk of ischemic stroke cardioembolic subtype. © 2015 The

  20. Using the Electronic Medical Record to Reduce Unnecessary Ordering of Coagulation Studies for Patients with Chest Pain

    PubMed Central

    Hinson, Jeremiah S.; Mistry, Binoy; Hsieh, Yu-Hsiang; Risko, Nicholas; Scordino, David; Paziana, Karolina; Peterson, Susan; Omron, Rodney

    2017-01-01

    Introduction Our goal was to reduce ordering of coagulation studies in the emergency department (ED) that have no added value for patients presenting with chest pain. We hypothesized this could be achieved via implementation of a stopgap measure in the electronic medical record (EMR). Methods We used a pre and post quasi-experimental study design to evaluate the impact of an EMR-based intervention on coagulation study ordering for patients with chest pain. A simple interactive prompt was incorporated into the EMR of our ED that required clinicians to indicate whether patients were on anticoagulation therapy prior to completion of orders for coagulation studies. Coagulation order frequency was measured via detailed review of randomly sampled encounters during two-month periods before and after intervention. We classified existing orders as clinically indicated or non-value added. Order frequencies were calculated as percentages, and we assessed differences between groups by chi-square analysis. Results Pre-intervention, 73.8% (76/103) of patients with chest pain had coagulation studies ordered, of which 67.1% (51/76) were non-value added. Post-intervention, 38.5% (40/104) of patients with chest pain had coagulation studies ordered, of which 60% (24/40) were non-value added. There was an absolute reduction of 35.3% (95% confidence interval [CI]: 22.7%, 48.0%) in the total ordering of coagulation studies and 26.4% (95% CI: 13.8%, 39.0%) in non-value added order placement. Conclusion Simple EMR-based interactive prompts can serve as effective deterrents to indiscriminate ordering of diagnostic studies. PMID:28210363

  1. Using the Electronic Medical Record to Reduce Unnecessary Ordering of Coagulation Studies for Patients with Chest Pain.

    PubMed

    Hinson, Jeremiah S; Mistry, Binoy; Hsieh, Yu-Hsiang; Risko, Nicholas; Scordino, David; Paziana, Karolina; Peterson, Susan; Omron, Rodney

    2017-02-01

    Our goal was to reduce ordering of coagulation studies in the emergency department (ED) that have no added value for patients presenting with chest pain. We hypothesized this could be achieved via implementation of a stopgap measure in the electronic medical record (EMR). We used a pre and post quasi-experimental study design to evaluate the impact of an EMR-based intervention on coagulation study ordering for patients with chest pain. A simple interactive prompt was incorporated into the EMR of our ED that required clinicians to indicate whether patients were on anticoagulation therapy prior to completion of orders for coagulation studies. Coagulation order frequency was measured via detailed review of randomly sampled encounters during two-month periods before and after intervention. We classified existing orders as clinically indicated or non-value added. Order frequencies were calculated as percentages, and we assessed differences between groups by chi-square analysis. Pre-intervention, 73.8% (76/103) of patients with chest pain had coagulation studies ordered, of which 67.1% (51/76) were non-value added. Post-intervention, 38.5% (40/104) of patients with chest pain had coagulation studies ordered, of which 60% (24/40) were non-value added. There was an absolute reduction of 35.3% (95% confidence interval [CI]: 22.7%, 48.0%) in the total ordering of coagulation studies and 26.4% (95% CI: 13.8%, 39.0%) in non-value added order placement. Simple EMR-based interactive prompts can serve as effective deterrents to indiscriminate ordering of diagnostic studies.

  2. Decreased haemodynamic response and decoupling of cortical gamma-band activity and tissue oxygen perfusion after striatal interleukin-1 injection.

    PubMed

    Bray, Natasha; Burrows, Fiona E; Jones, Myles; Berwick, Jason; Allan, Stuart M; Schiessl, Ingo

    2016-08-24

    Neurovascular coupling describes the mechanism by which the energy and oxygen demand arising from neuronal activity is met by an increase in regional blood flow, known as the haemodynamic response. Interleukin 1 (IL-1) is a pro-inflammatory cytokine and an important mediator of neuronal injury, though mechanisms through which IL-1 exerts its effects in the brain are not fully understood. In this study, we set out to investigate if increased cerebral levels of IL-1 have a negative effect on the neurovascular coupling in the cortex in response to sensory stimulation. We used two approaches to measure the neuronal activity and haemodynamic changes in the anaesthetised rat barrel somatosensory cortex in response to mechanical whisker stimulation, before and for 6 h after intra-striatal injection of interleukin-1β or vehicle. First, we used two-dimensional optical imaging spectroscopy (2D-OIS) to measure the size of the functional haemodynamic response, indicated by changes of oxyhaemoglobin (HbO2) and total haemoglobin (HbT) concentration. In the same animals, immunostaining of immunoglobulin G and SJC-positive extravasated neutrophils was used to confirm the pro-inflammatory effects of interleukin-1β (IL-1β). Second, to examine the functional coupling between neuronal activity and the haemodynamic response, we used a 'Clark-style' electrode combined with a single sharp electrode to simultaneously record local tissue oxygenation (partial pressure oxygen, pO2) in layer IV/V of the stimulated barrel cortex and multi-unit activity (MUA) together with local field potentials (LFPs), respectively. 2D-OIS data revealed that the size of the haemodynamic response to mechanical whisker stimulation declined over the 6 h following IL-1β injection whereas the vehicle group remained stable, significant differences being seen after 5 h. Moreover, the size of the transient increases of neuronal LFP activity in response to whisker stimulation decreased after IL-1β injection

  3. Onset of Coagulation Function Recovery Is Delayed in Severely Injured Trauma Patients with Venous Thromboembolism.

    PubMed

    McCully, Belinda H; Connelly, Christopher R; Fair, Kelly A; Holcomb, John B; Fox, Erin E; Wade, Charles E; Bulger, Eileen M; Schreiber, Martin A

    2017-07-01

    Altered coagulation function after trauma can contribute to development of venous thromboembolism (VTE). Severe trauma impairs coagulation function, but the trajectory for recovery is not known. We hypothesized that enhanced, early recovery of coagulation function increases VTE risk in severely injured trauma patients. Secondary analysis was performed on data from the Pragmatic Randomized Optimal Platelet and Plasma Ratio (PROPPR) trial, excluding patients who died within 24 hours or were on pre-injury anticoagulants. Patient characteristics, adverse outcomes, and parameters of platelet function and coagulation (thromboelastography) were compared from admission to 72 hours between VTE (n = 83) and non-VTE (n = 475) patients. A p value < 0.05 indicates significance. Despite similar patient demographics, VTE patients exhibited hypercoagulable thromboelastography parameters and enhanced platelet function at admission (p < 0.05). Both groups exhibited hypocoagulable thromboelastography parameters, platelet dysfunction, and suppressed clot lysis (low clot lysis at 30 minutes) 2 hours after admission (p < 0.05). The VTE patients exhibited delayed coagulation recovery (a significant change compared with 2 hours) of K-value (48 vs 24 hours), α-angle (no recovery), maximum amplitude (24 vs 12 hours), and clot lysis at 30 minutes (48 vs 12 hours). Platelet function recovery mediated by arachidonic acid (72 vs 4 hours), ADP (72 vs 12 hours), and collagen (48 vs 12 hours) was delayed in VTE patients. The VTE patients had lower mortality (4% vs 13%; p < 0.05), but fewer hospital-free days (0 days [interquartile range 0 to 8 days] vs 10 days [interquartile range 0 to 20 days]; p < 0.05) and higher complication rates (p < 0.05). Recovery from platelet dysfunction and coagulopathy after severe trauma were delayed in VTE patients. Suppressed clot lysis and compensatory mechanisms associated with altered coagulation that can potentiate VTE formation require additional

  4. Optimum coagulant forecasting by modeling jar test experiments using ANNs

    NASA Astrophysics Data System (ADS)

    Haghiri, Sadaf; Daghighi, Amin; Moharramzadeh, Sina

    2018-01-01

    Currently, the proper utilization of water treatment plants and optimizing their use is of particular importance. Coagulation and flocculation in water treatment are the common ways through which the use of coagulants leads to instability of particles and the formation of larger and heavier particles, resulting in improvement of sedimentation and filtration processes. Determination of the optimum dose of such a coagulant is of particular significance. A high dose, in addition to adding costs, can cause the sediment to remain in the filtrate, a dangerous condition according to the standards, while a sub-adequate dose of coagulants can result in the reducing the required quality and acceptable performance of the coagulation process. Although jar tests are used for testing coagulants, such experiments face many constraints with respect to evaluating the results produced by sudden changes in input water because of their significant costs, long time requirements, and complex relationships among the many factors (turbidity, temperature, pH, alkalinity, etc.) that can influence the efficiency of coagulant and test results. Modeling can be used to overcome these limitations; in this research study, an artificial neural network (ANN) multi-layer perceptron (MLP) with one hidden layer has been used for modeling the jar test to determine the dosage level of used coagulant in water treatment processes. The data contained in this research have been obtained from the drinking water treatment plant located in Ardabil province in Iran. To evaluate the performance of the model, the mean squared error (MSE) and correlation coefficient (R2) parameters have been used. The obtained values are within an acceptable range that demonstrates the high accuracy of the models with respect to the estimation of water-quality characteristics and the optimal dosages of coagulants; so using these models will allow operators to not only reduce costs and time taken to perform experimental jar tests

  5. Two distinct forms of Factor VIII coagulant protein in human plasma. Cleavage by thrombin, and differences in coagulant activity and association with von Willebrand factor.

    PubMed Central

    Weinstein, M J; Chute, L E

    1984-01-01

    We have characterized Factor VIII coagulant protein, present in normal human plasma, that reacts with a specific human 125I-labeled anti-human VIII:C antigen Fab antibody fragment. Two major Factor VIII coagulant antigen populations were present. The first, approximately 85% of the total antigen, was bound to von Willebrand factor and when tested in a standard one-stage assay had Factor VIII coagulant activity. The second antigenic population, eluting near fibrinogen when plasma was gel filtered, was not bound to von Willebrand protein, did not have Factor VIII coagulant activity unless activated, but did block anti-VIII:C Fab neutralization of clotting activity. The two antigenic populations were separable by cryoprecipitation and agarose gel electrophoresis. Although the two antigenic populations differed in their Factor VIII coagulant activity and in their binding to von Willebrand factor, the principal member of both populations is of mol wt 2.4 X 10(5). Both antigens, when proteolyzed by thrombin, were quickly converted to a 1 X 10(5)-mol wt form in association with the appearance of VIII:C activity. The 1 X 10(5)-mol wt antigen was further slowly degraded to an 8 X 10(4)-mol wt form while Factor VIII coagulant activity declined. These results demonstrate the presence of an inactive Factor VIII coagulant protein in plasma, not associated with von Willebrand factor, that can react with thrombin to yield Factor VIII coagulant activity. Images PMID:6421875

  6. Interplay between coagulation and vascular inflammation in sickle cell disease

    PubMed Central

    Sparkenbaugh, Erica; Pawlinski, Rafal

    2013-01-01

    Sickle cell disease is the most common inherited hematologic disorder that leads to the irreversible damage of multiple organs. Although sickling of red blood cells and vaso-occlusion are central to the pathophysiology of sickle cell disease the importance of hemolytic anemia and vasculopathy has been recently recognized. Hypercoagulation state is another prominent feature of sickle cell disease and is mediated by activation of both intrinsic and extrinsic coagulation pathways. Growing evidence demonstrates that coagulation may not only contribute to the thrombotic complications, but also to vascular inflammation associated with this disease. This article summarizes the role of vascular inflammation and coagulation activation, discusses potential mechanisms responsible for activation of coagulation and reviews recent data demonstrating the crosstalk between coagulation and vascular inflammation in sickle cell disease. PMID:23593937

  7. Time course of haemodynamic, respiratory and inflammatory disturbances induced by experimental acute pulmonary polystyrene microembolism.

    PubMed

    Dolci, Daniel T; Fuentes, Carolina B; Rolim, Denise; Park, Marcelo; Schettino, Guilherme P P; Azevedo, Luciano C P

    2010-01-01

    The time course of cardiopulmonary alterations after pulmonary embolism has not been clearly demonstrated and nor has the role of systemic inflammation on the pathogenesis of the disease. This study aimed to evaluate over 12 h the effects of pulmonary embolism caused by polystyrene microspheres on the haemodynamics, lung mechanics and gas exchange and on interleukin-6 production. Ten large white pigs (weight 35-42 kg) had arterial and pulmonary catheters inserted and pulmonary embolism was induced in five pigs by injection of polystyrene microspheres (diameter approximately 300 micromol l(-1)) until a value of pulmonary mean arterial pressure of twice the baseline was obtained. Five other animals received only saline. Haemodynamic and respiratory data and pressure-volume curves of the respiratory system were collected. A bronchoscopy was performed before and 12 h after embolism, when the animals were euthanized. The embolism group developed hypoxaemia that was not corrected with high oxygen fractions, as well as higher values of dead space, airway resistance and lower respiratory compliance levels. Acute haemodynamic alterations included pulmonary arterial hypertension with preserved systemic arterial pressure and cardiac index. These derangements persisted until the end of the experiments. The plasma interleukin-6 concentrations were similar in both groups; however, an increase in core temperature and a nonsignificant higher concentration of bronchoalveolar lavage proteins were found in the embolism group. Acute pulmonary embolism induced by polystyrene microspheres in pigs produces a 12-h lasting hypoxaemia and a high dead space associated with high airway resistance and low compliance. There were no plasma systemic markers of inflammation, but a higher central temperature and a trend towards higher bronchoalveolar lavage proteins were found.

  8. Household air pollution and measures of blood pressure, arterial stiffness and central haemodynamics.

    PubMed

    Baumgartner, Jill; Carter, Ellison; Schauer, James J; Ezzati, Majid; Daskalopoulou, Stella S; Valois, Marie-France; Shan, Ming; Yang, Xudong

    2018-02-09

    We evaluated the exposure-response associations between personal exposure to air pollution from biomass stoves and multiple vascular and haemodynamic parameters in rural Chinese women. We analysed the baseline information from a longitudinal study in southwestern China. Women's brachial and central blood pressure and pulse pressure, carotid-femoral pulse wave velocity and augmentation index, and their 48-hour personal exposures to fine particulate matter (PM 2.5 ) and black carbon were measured in summer and winter. We evaluated the associations between exposure to air pollution and haemodynamic parameters using mixed-effects regression models adjusted for known cardiovascular risk factors. Women's (n=205, ages 27-86 years) exposures to PM 2.5 and black carbon ranged from 14 µg/m 3 to 1405 µg/m 3 and 0.1-121.8 µg/m 3 , respectively. Among women aged ≥50 years, increased PM 2.5 exposure was associated with higher systolic (brachial: 3.5 mm Hg (P=0.05); central: 4.4 mm Hg (P=0.005)) and diastolic blood pressure (central: 1.3 mm Hg (P=0.10)), higher pulse pressure (peripheral: 2.5 mm Hg (P=0.05); central: 2.9 mm Hg (P=0.008)) and lower peripheral-central pulse pressure amplification (-0.007 (P=0.04)). Among younger women, the associations were inconsistent in the direction of effect and not statistically significant. Increased PM 2.5 exposure was associated with no difference in pulse wave velocity and modestly higher augmentation index though the CI included zero (1.1%; 95% CI -0.2% to 2.4%). Similar associations were found for black carbon exposure. Exposure to household air pollution was associated with higher blood pressure and central haemodynamics in older Chinese women, with no associations observed with pulse wave velocity. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Colloids removal from water resources using natural coagulant: Acacia auriculiformis

    NASA Astrophysics Data System (ADS)

    Abdullah, M.; Roslan, A.; Kamarulzaman, M. F. H.; Erat, M. M.

    2017-09-01

    All waters, especially surface waters contain dissolved, suspended particles and/or inorganic matter, as well as several biological organisms, such as bacteria, algae or viruses. This material must be removed because it can affect the water quality that can cause turbidity and colour. The objective of this study is to develop water treatment process from Seri Alam (Johor, Malaysia) lake water resources by using natural coagulant Acacia auriculiformis pods through a jar test experiment. Jar test is designed to show the effectiveness of the water treatment. This process is a laboratory procedure that will simulate coagulation/flocculation with several parameters selected namely contact time, coagulant dosage and agitation speed. The most optimum percentage of colloids removal for each parameter is determined at 0.2 g, 90 min and 80 rpm. FESEM (Field-emission Scanning Electron Microscope) observed the small structures of final floc particles for optimum parameter in this study to show that the colloids coagulated the coagulant. All result showed that the Acacia auriculiformis pods can be a very efficient coagulant in removing colloids from water.

  10. Tissue Factor Coagulant Activity is Regulated by the Plasma Membrane Microenvironment.

    PubMed

    Yu, Yuanjie; Böing, Anita N; Hau, Chi M; Hajji, Najat; Ruf, Wolfram; Sturk, Auguste; Nieuwland, Rienk

    2018-06-01

     Tissue factor (TF) can be present in a non-coagulant and coagulant form. Whether the coagulant activity is affected by the plasma membrane microenvironment is unexplored.  This article studies the presence and coagulant activity of human TF in plasma membrane micro-domains.  Plasma membranes were isolated from human MIA PaCa2 cells, MDA-MB-231 cells and human vascular smooth muscle cells by Percoll gradient ultracentrifugation after cell disruption. Plasma membranes were fractionated by OptiPrep gradient ultracentrifugation, and the presence of TF, flotillin, caveolin, clathrin, protein disulphide isomerase (PDI), TF pathway inhibitor (TFPI) and phosphatidylserine (PS) were determined.  Plasma membranes contain two detergent-resistant membrane (DRM) compartments differing in density and biochemical composition. High-density DRMs (DRM-H) have a density ( ρ ) of 1.15 to 1.20 g/mL and contain clathrin, whereas low-density DRMs (DRM-L) have a density between 1.09 and 1.13 g/mL and do not contain clathrin. Both DRMs contain TF, flotillin and caveolin. PDI is detectable in DRM-H, TFPI is not detectable in either DMR-H or DRM-L and PS is detectable in DRM-L. The DRM-H-associated TF (> 95% of the TF antigen) lacks detectable coagulant activity, whereas the DRM-L-associated TF triggers coagulation. This coagulant activity is inhibited by lactadherin and thus PS-dependent, but seemed insensitive to 16F16, an inhibitor of PDI.  Non-coagulant and coagulant TF are present within different types of DRMs in the plasma membrane, and the composition of these DRMs may affect the TF coagulant activity. Schattauer GmbH Stuttgart.

  11. Infrared coagulation: a new treatment for hemorrhoids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leicester, R.J.; Nicholls, R.J.; Mann, C.V.

    Many methods, which have effectively reduced the number of patients requiring hospital admission, have been described for the outpatient treatment of hemorrhoids. However, complications have been reported, and the methods are often associated with unpleasant side effects. In 1977 Neiger et al. described a new method that used infrared coagulation, which produced minimal side effects. The authors have conducted a prospective, randomized trial to evaluate infrared coagulation compared with more traditional methods of treatment. The authors' results show that it may be more effective than injection sclerotherapy in treating non-prolapsing hemorrhoids and that it compares favorably with rubber band ligationmore » in most prolapsing hemorrhoids. No complications occurred, and significantly fewer patients experienced pain after infrared coagulation (P . less than 0.001).« less

  12. Intraseptal vs. periodontal ligament anaesthesia for maxillary tooth extraction: quality of local anaesthesia and haemodynamic response.

    PubMed

    Brkovic, Bozidar M B; Savic, Miroslav; Andric, Miroslav; Jurisic, Milan; Todorovic, Ljubomir

    2010-12-01

    There is no data concerning the use of the intraseptal anaesthesia (ISA) for single tooth extraction. The aims of this study were to compare the clinical efficacy and haemodynamic responses of the ISA with the periodontal ligament anaesthesia (PLA) for single tooth extraction. Thirty-five randomly selected healthy patients (ASA I) undergoing maxillary lateral incisors extraction entered the study. Onset of anaesthesia, the width of the anaesthetic field and duration of anaesthesia were recorded by pinprick testing. Intensity of anaesthesia was evaluated on a visual analogue scale. Haemodynamic parameters were recorded simultaneously at different time points after anaesthesia injection. The two techniques of local anaesthesia did not show statistically significant differences regarding the success rate and onset of anaesthesia, while the duration of the ISA on the buccal site was significantly longer in comparison with the PLA. The intensity of the achieved anaesthesia, estimated by the experienced pain during procedure, pointed out that pain was recorded in 24% of cases in the ISA group, and in 19% in the PLA group without significant differences. Postoperative pain was found to be smaller in the ISA group (70.9% of treated sites) than in the PLA group (81.3% of treated sites); however, this difference was not significant. Although the heart rate increased in both groups, there were no significant differences in the patients' haemodynamic response between the ISA and the PLA. The results of the present study indicate that both techniques are useful and suitable for the routine tooth extraction.

  13. [Comparison of shaft temperature related treatment efficacy between "air-cooled" microwave coagulation and traditional microwave coagulation].

    PubMed

    Zheng, Yun; Li, Jin-Qing; Chen, Min-Shan; Zhang, Yao-Jun; Zhang, Ya-Qi

    2004-11-01

    The application and development of traditional percutaneous microwave coagulation therapy (PMCT) has been limited by high shaft temperature. The "air-cooled" PMCT is the newest advancement. This study was to compare shaft temperature related treatment efficacy between "air-cooled" PMCT and traditional PMCT. Two pigs underwent traditional PMCT, and "air-cooled" PMCT at 80 W for 10 min separately. Skin injury, surface temperature of guide-needle, charring tissue sticking to the shaft, and lesion shape in 2 pigs were compared. Five patients with liver tumor received traditional PMCT, and 8 patients with liver tumor received "air-cooled" PMCT. Feeling of pain, skin injury, charring tissue sticking to the shaft, local therapeutic efficacy, and recurrence of these 2 groups of patients were compared. In the pig underwent traditional PMCT, surface temperature of guide-needle reached 119-160 Centigrade; skin burn around puncture points was serious; charring tissue stuck to the front of electrodes; a trail sign was observed in coagulated lesion. In the pig underwent "air-cooled" PMCT, surface temperature of guide-needle was 28.8-39.9 Centigrade; no skin injury was found around puncture points; no charring tissue stuck to the front of electrodes; no obvious trail sign was observed in coagulated lesion. In 5 patients received traditional PMCT, 3 had skin injury; 2 had charring tissue stuck to the front of electrode; all felt moderate or serious epigastric pain lasted for 1-8 weeks; 4 had complete coagulation; 1 had local recurrence. In 8 patients received "air-cooled" PMCT, no one had skin injury, and charring tissue stuck to "air-cooled" electrode; 4 felt slight epigastric pain within 1 week; all had complete coagulation; no local recurrence was found. The technique of "air-cooled" electrode may decrease temperature of shaft safely and reliably, and eliminate side effects arose from high temperature of shaft. Treatment efficacy of "air-cooled" PMCT is better than that of

  14. Coagulation management in patients undergoing neurosurgical procedures.

    PubMed

    Robba, Chiara; Bertuetti, Rita; Rasulo, Frank; Bertuccio, Alessando; Matta, Basil

    2017-10-01

    Management of coagulation in neurosurgical procedures is challenging. In this contest, it is imperative to avoid further intracranial bleeding. Perioperative bleeding can be associated with a number of factors, including anticoagulant drugs and coagulation status but is also linked to the characteristic and the site of the intracranial disorder. The aim of this review will be to focus primarily on the new evidence regarding the management of coagulation in patients undergoing craniotomy for neurosurgical procedures. Antihemostatic and anticoagulant drugs have shown to be associated with perioperative bleeding. On the other hand, an increased risk of venous thromboembolism and hypercoagulative state after elective and emergency neurosurgery, in particular after brain tumor surgery, has been described in several patients. To balance the risk between thrombosis and bleeding, it is important to be familiar with the perioperative changes in coagulation and with the recent management guidelines for anticoagulated patients undergoing neurosurgical procedures, in particular for those taking new direct anticoagulants. We have considered the current clinical trials and literature regarding both safety and efficacy of deep venous thrombosis prophylaxis in the neurosurgical population. These were mainly trials concerning both elective surgical and intensive care patients with a poor grade intracranial bleed or multiple traumas with an associated severe traumatic brain injury (TBI). Coagulation management remains a major issue in patients undergoing neurosurgical procedures. However, in this field of research, literature quality is poor and further studies are necessary to identify the best strategies to minimize risks in this group of patients.

  15. A novel protein mixture containing vegetable proteins renders enteral nutrition products non-coagulating after in vitro gastric digestion.

    PubMed

    van den Braak, Claudia C M; Klebach, Marianne; Abrahamse, Evan; Minor, Marcel; Hofman, Zandrie; Knol, Jan; Ludwig, Thomas

    2013-10-01

    Non-coagulation of protein from enteral nutrition (EN) in the stomach is considered to improve gastric emptying and may result in reduced upper gastrointestinal complications such as reflux and aspiration pneumonia. For the development of a new EN protein mixture with reduced gastric coagulation, the coagulating properties of individual proteins, a novel blend of four proteins (P4 protein blend) and commercial EN products were investigated. A semi-dynamic, computer controlled setup was developed to mimic gastric digestion. The coagulation behaviour of 150 ml protein solutions and EN products was investigated. These were heat-treated calcium caseinate, sodium caseinate, whey, soy and pea protein, and the P4 protein blend comprising of the latter four (all solutions 6% w/v protein), four new enteral nutrition product varieties (New Nutrison® .0 or 1.5 kcal/ml, with and without MultiFibre MF6™) based on the P4 protein blend and two other commercially available casein dominant EN products (T1 and T2). Calcium caseinate and sodium caseinate yielded a total wet coagulate of 43.5 ± 0.7 g and 52.7 ± 6.2 g, respectively. Whey, soy, pea and the P4 protein blend did not produce any measurable coagulate. T1 and T2 resulted in a total wet coagulate of 37.5 ± 0.8 g and 57.3 ± 0.8 g, respectively, while all new EN product varieties based on the P4 protein blend did not produce any measurable coagulate. The P4 protein blend renders EN product varieties non-coagulating after in vitro gastric digestion. Copyright © 2012 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  16. 21 CFR 878.4400 - Electrosurgical cutting and coagulation device and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrosurgical cutting and coagulation device and....4400 Electrosurgical cutting and coagulation device and accessories. (a) Identification. An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control...

  17. MR Coagulation: A Novel Minimally Invasive Approach to Aneurysm Repair.

    PubMed

    Cohen, Ouri; Zhao, Ming; Nevo, Erez; Ackerman, Jerome L

    2017-11-01

    To demonstrate a proof of concept of magnetic resonance (MR) coagulation, in which MR imaging scanner-induced radiofrequency (RF) heating at the end of an intracatheter long wire heats and coagulates a protein solution to effect a vascular repair by embolization. MR coagulation was simulated by finite-element modeling of electromagnetic fields and specific absorption rate (SAR) in a phantom. A glass phantom consisting of a spherical cavity joined to the side of a tube was incorporated into a flow system to simulate an aneurysm and flowing blood with velocities of 0-1.7 mL/s. A double-lumen catheter containing the wire and fiberoptic temperature sensor in 1 lumen was passed through the flow system into the aneurysm, and 9 cm 3 of protein solution was injected into the aneurysm through the second lumen. The distal end of the wire was laid on the patient table as an antenna to couple RF from the body coil or was connected to a separate tuned RF pickup coil. A high RF duty-cycle turbo spin-echo pulse sequence excited the wire such that RF energy deposited at the tip of the wire coagulated the protein solution, embolizing the aneurysm. The protein coagulation temperature of 60°C was reached in the aneurysm in ∼12 seconds, yielding a coagulated mass that largely filled the aneurysm. The heating rate was controlled by adjusting pulse-sequence parameters. MR coagulation has the potential to embolize vascular defects by coagulating a protein solution delivered by catheter using MR imaging scanner-induced RF heating of an intracatheter wire. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  18. Activation of blood coagulation in cancer: implications for tumour progression

    PubMed Central

    Lima, Luize G.; Monteiro, Robson Q.

    2013-01-01

    Several studies have suggested a role for blood coagulation proteins in tumour progression. Herein, we discuss (1) the activation of the blood clotting cascade in the tumour microenvironment and its impact on primary tumour growth; (2) the intravascular activation of blood coagulation and its impact on tumour metastasis and cancer-associated thrombosis; and (3) antitumour therapies that target blood-coagulation-associated proteins. Expression levels of the clotting initiator protein TF (tissue factor) have been correlated with tumour cell aggressiveness. Simultaneous TF expression and PS (phosphatidylserine) exposure by tumour cells promote the extravascular activation of blood coagulation. The generation of blood coagulation enzymes in the tumour microenvironment may trigger the activation of PARs (protease-activated receptors). In particular, PAR1 and PAR2 have been associated with many aspects of tumour biology. The procoagulant activity of circulating tumour cells favours metastasis, whereas the release of TF-bearing MVs (microvesicles) into the circulation has been correlated with cancer-associated thrombosis. Given the role of coagulation proteins in tumour progression, it has been proposed that they could be targets for the development of new antitumour therapies. PMID:23889169

  19. Treatment of phosphate-containing oily wastewater by coagulation and microfiltration.

    PubMed

    Zhang, Jin; Sun, Yu-xin; Huang, Zhi-feng; Liu, Xing-qin; Meng, Guang-yao

    2006-01-01

    The oily wastewater generated from pretreatment unit of electrocoating industry contains oils, phosphate, organic solvents, and surfactants. In order to improve the removal efficiencies of phosphate and oils, to mitigate the membrane fouling, coagulation for ceramic membrane microfiltration of oily wastewater was performed. The results of filtration tests show that the membrane fouling decreased and the permeate flux and quality increased with coagulation as pretreatment. At the coagulant Ca (OH)2 dosage of 900 mg/L, the removal efficiency of phosphate was increased from 46.4% without coagulation to 99.6%; the removal of COD and oils were 97.0% and 99.8%, respectively. And the permeate flux was about 70% greater than that when Ca(OH)2 was not used. The permeate obtained from coagulation and microfiltration can be reused as make-up water, and the recommended operation conditions for pilot and industrial application are transmembrane pressure of 0.10 MPa and cross-flow velocity of 5 m/s. The comparison results show that 0.2 microm ZrO2 microfilter with coagulation could be used to perform the filtration rather than conventional ultrafilter, with very substantial gain in flux and removal efficiency of phosphate.

  20. Haemodynamic responses in chronically painful, human trapezius muscle to cold pressor stimulation.

    PubMed

    Acero, C O; Kuboki, T; Maekawa, K; Yamashita, A; Clark, G T

    1999-10-01

    The aim was to compare haemodynamic responses in trapezius muscles to cold pressor stimulation in individuals with localized trapezius myalgia and asymptomatic controls. Nine males with chronic localized pain in the trapezius (mean age, 23.2 years) and nine male controls (mean age, 24.6 years) who had no medical history of migraine, hypertension or sustained pain in the trapezius region were investigated. Two experimental (cold pressor and mock) trials were performed in a randomly assigned sequence. In the cold pressor trial the participant's left foot and ankle were immersed in 4 degrees C cold water for 2 min; the mock trial was done without that stimulus. Blood volume was continuously recorded 1 min before, 2 min during, and 5 min after cold pressor stimulation using near-infrared spectroscopy. Each participant's blood-volume data were baseline-corrected and submitted to statistical analysis. Results showed that the individuals with muscle pain exhibited a significantly lower mean blood volume than the controls during cold pressor stimulation (p = 0.0367). Upon withdrawal of that stimulation, the mean blood volume in both groups fell below the baseline. These results suggest that individuals with chronic regional trapezius myalgia have less capacity to vasodilate this muscle during cold pressor stimulation than those without such myalgia. It is not yet known if this difference in the haemodynamic response is a cause or an effect of the myalgia.

  1. Haemodynamic responses and changes of haemostatic risk factors in cold-adapted humans.

    PubMed

    De Lorenzo, F; Kadziola, Z; Mukherjee, M; Saba, N; Kakkar, V V

    1999-09-01

    Epidemiological studies have shown an increase in acute myocardial infarctions or deaths due to myocardial infarction in colder weather; the mechanisms most likely involve increased blood levels of haemostatic risk factors, and increases in arterial blood pressure and heart rate. We studied the relationship between cold adaptation, haemostatic risk factors and haemodynamic variables. Cold adaptation was obtained by a programme of immersion of the whole body up to the neck in a water-filled bath, the temperature of which was gradually decreased from 22 degrees C to 14 degrees C, time of exposure being increased from 5 to 20 min over a period of 90 days. We studied 428 patients (44% men) and measured blood levels of fibrinogen, plasminogen activator inhibitor 1 (PAI-1), tissue plasminogen activator antigen (t-PA), plasma viscosity, von Willebrand factor, D-dimer and platelet count, both at baseline and after 90 days of daily immersion. There were significant reductions in von Willebrand factor (-3%; p < 0.001), and plasma viscosity (-3.0 s; p < 0.001), and a mild but significant increase in PAI-1 (+0.3 IU/ml; p = 0.02). The pressure rate product (systolic blood pressure x heart rate) was also significantly lower after cold adaptation (-310; p = 0.004). Cold adaptation, compared with exposure to cold weather, induces different haemodynamic responses and changes of blood levels of haemostatic risk factors.

  2. Effects of sodium citrate, citric acid and lactic acid on human blood coagulation.

    PubMed

    Scaravilli, Vittorio; Di Girolamo, Luca; Scotti, Eleonora; Busana, Mattia; Biancolilli, Osvaldo; Leonardi, Patrizia; Carlin, Andrea; Lonati, Caterina; Panigada, Mauro; Pesenti, Antonio; Zanella, Alberto

    2018-05-01

    Citric acid infusion in extracorporeal blood may allow concurrent regional anticoagulation and enhancement of extracorporeal CO 2 removal. Effects of citric acid on human blood thromboelastography and aggregometry have never been tested before. In this in vitro study, citric acid, sodium citrate and lactic acid were added to venous blood from seven healthy donors, obtaining concentrations of 9 mEq/L, 12 mEq/L and 15 mEq/L. We measured gas analyses, ionized calcium (iCa ++ ) concentration, activated clotting time (ACT), thromboelastography and multiplate aggregometry. Repeated measure analysis of variance was used to compare the acidifying and anticoagulant properties of the three compounds. Sodium citrate did not affect the blood gas analysis. Increasing doses of citric and lactic acid progressively reduced pH and HCO 3 - and increased pCO 2 (p<0.001). Sodium citrate and citric acid similarly reduced iCa ++ , from 0.39 (0.36-0.39) and 0.35 (0.33-0.36) mmol/L, respectively, at 9 mEq/L to 0.20 (0.20-0.21) and 0.21 (0.20-0.23) mmol/L at 15 mEq/L (p<0.001). Lactic acid did not affect iCa ++ (p=0.07). Sodium citrate and citric acid similarly incremented the ACT, from 234 (208-296) and 202 (178-238) sec, respectively, at 9 mEq/L, to >600 sec at 15 mEq/L (p<0.001). Lactic acid did not affect the ACT values (p=0.486). Sodium citrate and citric acid similarly incremented R-time and reduced α-angle and maximum amplitude (MA) (p<0.001), leading to flat-line thromboelastograms at 15 mEq/L. Platelet aggregometry was not altered by any of the three compounds. Citric acid infusions determine acidification and anticoagulation of blood similar to lactic acid and sodium citrate, respectively.

  3. Reflexology has no immediate haemodynamic effect in patients with chronic heart failure: a double blind randomised controlled trial.

    PubMed

    Jones, Jenny; Thomson, Patricia; Lauder, William; Howie, Kate; Leslie, Stephen J

    2013-08-01

    This study measured the effects of reflexology in 12 reflexology-naive patients with chronic heart failure in a placebo-controlled, double blind randomised controlled study design. Outcomes included 'beat-to-beat' non-invasive continuous measurement of cardiovascular parameters and measurement of state of anxiety and pain/discomfort. There were no changes in any of the haemodynamic parameters measured (all p > 0.05). Perceived state of anxiety was significantly reduced post treatment in the control group only (p = 0.03). Reflexology applied to the feet of patients with chronic heart failure appears to have no immediate haemodynamic effects. While any long term treatment effect is uncertain, it would appear that reflexology is safe for use in this patient group. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Fluorescence excitation-emission matrix spectroscopy analysis of landfill leachate DOM in coagulation-flocculation process.

    PubMed

    Zhu, Guocheng; Wang, Chuang; Dong, Xingwei

    2017-06-01

    Landfill leachate contains a variety of organic matters, some of which can be excited and emit fluorescence signal. In order to degrade these organic matters, the pretreatment of the leachate is needed, which can improve the degradation performance of post-treatment process. Coagulation-flocculation is one of the important pretreatment processes to treat landfill leachate. Assessing the chemical compositions of landfill leachate is helpful in the understanding of their sources and fates as well as the mechanistic behaviors in the water environment. The present work aimed to use fluorescence excitation-emission matrix spectroscopy (EEMs) to characterize the chemical fractions of landfill leachate dissolved organic matter (DOM) in conjunction with parallel factor analysis (PARAFAC). Results showed that the DOM of landfill leachate tested in this study was identified resulting from microbial input, which included five typical characteristic peaks and four kinds of PARAFAC fractions. These fractions were mainly composed of hydrophobic macromolecule humic acid-like (HM-HA), hydrophilic intermediate molecular fulvic acid-like (HIM-FA), and hydrophilic small molecule protein-like substances (HSM-PS). HM-HA and HIM-FA were found to be easier to remove than HSM-PS. Further research on HSM-PS removal by coagulation-flocculation still needs to be improved.

  5. 21 CFR 864.5425 - Multipurpose system for in vitro coagulation studies.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Multipurpose system for in vitro coagulation... Hematology Devices § 864.5425 Multipurpose system for in vitro coagulation studies. (a) Identification. A multipurpose system for in vitro coagulation studies is a device consisting of one automated or semiautomated...

  6. 21 CFR 864.5425 - Multipurpose system for in vitro coagulation studies.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Multipurpose system for in vitro coagulation... Hematology Devices § 864.5425 Multipurpose system for in vitro coagulation studies. (a) Identification. A multipurpose system for in vitro coagulation studies is a device consisting of one automated or semiautomated...

  7. Vitamin K: from coagulation to calcification.

    PubMed

    Paakkari, Ilari

    Vitamin K is not only essential for the synthesis of coagulation factors in the liver, but it also strengthens the bones and prevents calcification of the arteries. These effects are mediated through the same mechanism, i.e. carboxylation of Gla target proteins. The discovery of novel Gla proteins that are not associated with blood coagulation or calcium metabolism indicates that vitamin K has additional effects in the pancreas and the central nervous system, for example. As dietary supplements, vitamin K1 of plant origin and vitamins K2 of bacterial origin may exert different effects.

  8. Treatment of Wastewater From Car Washes Using Natural Coagulation and Filtration System

    NASA Astrophysics Data System (ADS)

    Al-Gheethi, A. A.; Mohamed, R. M. S. R.; Rahman, M. A. A.; Johari, M. R.; Kassim, A. H. M.

    2016-07-01

    Wastewater generated from carwash is one of the main wastewater resources, which contribute effectively in the increasing of environmental contamination due to the chemical characteristics of the car wastes. The present work aimed to develop an integrated treatment system for carwash wastewater based on coagulation and flocculation using Moringa oleifera and Ferrous Sulphate (FeSO4.7H2O) as well as natural filtration system. The carwash wastewater samples were collected from carwash station located at Parit Raja, Johor, Malaysia. The treatment system of car wash wastewater was designed in the lab scale in four stages included, aeration, coagulation and flocculation, sedimentation and filtration. The coagulation and flocculation unit was carried out using different dosage (35, 70, 105 and 140 mg L-1) of M. oleifera and FeSO4.7H2O, respectively. The efficiency of the integrated treatment system to treat carwash wastewater and to meet Environmental Quality Act (EQA 1974) was evaluated based on the analysis of pH, dissolved oxygen (DO), chemical oxygen demand (COD) and turbidity (NTU). The integrated treatment system was efficient for treatment of raw carwash wastewater. The treated carwash wastewaters meet EQA 1974 regulation 2009 (Standards A) in the term of pH and DO while, turbidity and COD reduced in the wastewater to meet Standards B. The integrated treatment system designed here with natural coagulant (M. oleifera) and filtration unit were effective for primary treatment of carwash wastewater before the final disposal or to be reused again for carwash process.

  9. The Mechanisms of Coagulation.

    ERIC Educational Resources Information Center

    Kurtz, Richard; Jesty, Jolyon

    1994-01-01

    Several topics such as heart disease, strokes, biochemical reactions, blood components, and genetics can be related to blood clotting. Introduces a simple, safe and inexpensive hands-on demonstration using bovine (cattle) blood plasma of normal and abnormal coagulation. (ZWH)

  10. Physiological levels of blood coagulation factors IX and X control coagulation kinetics in an in vitro model of circulating tissue factor

    NASA Astrophysics Data System (ADS)

    Tormoen, Garth W.; Khader, Ayesha; Gruber, András; McCarty, Owen J. T.

    2013-06-01

    Thrombosis significantly contributes to cancer morbidity and mortality. The mechanism behind thrombosis in cancer may be circulating tissue factor (TF), as levels of circulating TF are associated with thrombosis. However, circulating TF antigen level alone has failed to predict thrombosis in patients with cancer. We hypothesize that coagulation factor levels regulate the kinetics of circulating TF-induced thrombosis. Coagulation kinetics were measured as a function of individual coagulation factor levels and TF particle concentration. Clotting times increased when pooled plasma was mixed at or above a ratio of 4:6 with PBS. Clotting times increased when pooled plasma was mixed at or above a ratio of 8:2 with factor VII-depleted plasma, 7:3 with factor IX- or factor X-depleted plasmas, or 2:8 with factor II-, V- or VIII-depleted plasmas. Addition of coagulation factors VII, X, IX, V and II to depleted plasmas shortened clotting and enzyme initiation times, and increased enzyme generation rates in a concentration-dependent manner. Only additions of factors IX and X from low-normal to high-normal levels shortened clotting times and increased enzyme generation rates. Our results demonstrate that coagulation kinetics for TF particles are controlled by factor IX and X levels within the normal physiological range. We hypothesize that individual patient factor IX and X levels may be prognostic for susceptibility to circulating TF-induced thrombosis.

  11. Could light meal jeopardize laboratory coagulation tests?

    PubMed

    Lima-Oliveira, Gabriel; Salvagno, Gian Luca; Lippi, Giuseppe; Danese, Elisa; Gelati, Matteo; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2014-01-01

    Presently the necessity of fasting time for coagulation tests is not standardized. Our hypothesis is that this can harm patient safety. This study is aimed at evaluating whether a light meal (i.e. breakfast) can jeopardize laboratory coagulation tests. A blood sample was firstly collected from 17 fasting volunteers (12 h). Immediately after blood collection, the volunteers consumed a light meal. Then samples were collected at 1, 2 and 4 h after the meal. Coagulation tests included: activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fbg), antithrombin III (AT), protein C (PC) and protein S (PS). Differences between samples were assessed by Wilcoxon ranked-pairs test. The level of statistical significance was set at P < 0.05. Mean % differences were determined and differences between and baseline and 1, 2 and 4h samples were compared with reference change value (RCV). A significantly higher % activity of AT was observed at 1 h and 4 h after meal vs. baseline specimen [113 (104-117) and 111 (107-120) vs. 109 (102-118), respectively; P = 0.029 and P = 0.016]. APTT at 2 h was found significantly lower than baseline samples [32.0 (29.9-34.8) vs. 34.1 (32.2-35.2), respectively; P = 0.041]. The results of both Fbg and PS tests were not influenced by a light meal. Furthermore, no coagulation tests had significant variation after comparison with RCV. A light meal does not influence the laboratory coagulation tests we assessed, but we suggest that the laboratory quality managers standardize the fasting time for all blood tests at 12 hours, to completely metabolize the lipids intake.

  12. Application of Cox model in coagulation function in patients with primary liver cancer.

    PubMed

    Guo, Xuan; Chen, Mingwei; Ding, Li; Zhao, Shan; Wang, Yuefei; Kang, Qinjiong; Liu, Yi

    2011-01-01

    To analyze the distribution of coagulation parameters in patients with primary liver cancer; explore the relationship between clinical staging, survival, and coagulation parameters by using Coxproportional hazard model; and provide a parameter for clinical management and prognosis. Coagulation parameters were evaluated in 228 patients with primary liver cancer, 52 patients with common liver disease, and 52 normal healthy controls. The relationship between primary livercancer staging and coagulation parameters wasanalyzed. Follow-up examinations were performed. The Cox proportional hazard model was used to analyze the relationship between coagulationparameters and survival. The changes in the coagulation parameters in patients with primary liver cancer were significantly different from those in normal controls. The effect of the disease on coagulation function became more obvious as the severity of liver cancer increased (p<0.05). The levels of D-dimer, fibrinogen degradation products (FDP), fibrinogen (FIB), and platelets (PLT) were negatively correlated with the long-term survival of patients with advanced liver cancer. The stages of primary liver cancer are associated with coagulation parameters. Coagulation parameters are related to survival and risk factors. Monitoring of coagulation parameters may help ensure better surveillance and treatment for liver cancer patients.

  13. Blood coagulation reactions on nanoscale membrane surfaces

    NASA Astrophysics Data System (ADS)

    Pureza, Vincent S.

    Blood coagulation requires the assembly of several membrane-bound protein complexes composed of regulatory and catalytic subunits. The biomembranes involved in these reactions not only provide a platform for these procoagulant proteins, but can also affect their function. Increased exposure of acidic phospholipids on the outer leaflet of the plasma membrane can dramatically modulate the catalytic efficiencies of such membrane-bound enzymes. Under physiologic conditions, however, these phospholipids spontaneously cluster into a patchwork of membrane microdomains upon which membrane binding proteins may preferentially assemble. As a result, the membrane composition surrounding these proteins is largely unknown. Through the development and use of a nanometer-scale bilayer system that provides rigorous control of the phospholipid membrane environment, I investigated the role of phosphatidylserine, an acidic phospholipid, in the direct vicinity (within nanometers) of two critical membrane-bound procoagulant protein complexes and their respective natural substrates. Here, I present how the assembly and function of the tissue factor˙factor VIIa and factor Va˙factor Xa complexes, the first and final cofactor˙enzyme complexes of the blood clotting cascade, respectively, are mediated by changes in their immediate phospholipid environments.

  14. Catalytic decolorization of azo-stuff with electro-coagulation method assisted by cobalt phosphomolybdate modified kaolin.

    PubMed

    Zhuo, Qiongfang; Ma, Hongzhu; Wang, Bo; Gu, Lin

    2007-04-02

    The new catalytic decoloration of C.I. Acid Red 3R with electro-coagulation (EC) method assisted by cobalt phosphomolybdate modified kaolin has been studied. The result showed that this process could effectively remove the C.I. Acid Red 3R contained in wastewater and its color removal efficiency could reach up to 98.3% in 7 min. The kinetics of the catalytic decolorization of Acid Red 3R was also studied. The decolorization reaction order was dependent on the initial concentration [R](0) with respect to the concentration of C.I. Acid Red 3R. At lower [R](0) the order was first, which then decreases with increasing [R](0). The operating parameters such as initial pH, current density and temperature were also investigated. A possible reaction mechanism was proposed.

  15. Effect-site concentration of remifentanil required to blunt haemodynamic responses during tracheal intubation: A randomized comparison between single- and double-lumen tubes.

    PubMed

    Kim, Tae Kyong; Hong, Deok Man; Lee, Seo Hee; Paik, Hyesun; Min, Se Hee; Seo, Jeong-Hwa; Jung, Chul-Woo; Bahk, Jae-Hyon

    2018-01-01

    Objective To investigate the effect-site concentration of remifentanil required to blunt haemodynamic responses during tracheal intubation with a single-lumen tube (SLT) or a double-lumen tube (DLT). Methods Patients scheduled for thoracic surgery requiring one-lung ventilation were randomly allocated to either the SLT or DLT group. All patients received a target-controlled infusion of propofol and a predetermined concentration of remifentanil. Haemodynamic parameters during intubation were recorded. The effect-site concentration of remifentanil was determined using a delayed up-and-down sequential allocation method. Results A total of 92 patients were enrolled in the study. The effective effect-site concentrations of remifentanil required to blunt haemodynamic responses in 50% of patients (EC 50 ) estimated by isotonic regression with bootstrapping was higher in the DLT than the SLT group (8.5 ng/ml [95% confidence interval (CI) 8.0-9.5 ng/ml] versus 6.5 ng/ml [95% CI 5.6-6.7 ng/ml], respectively). Similarly, the effective effect-site concentrations of remifentanil in 95% of patients in the DLT group was higher than the SLT group (9.9 ng/ml [95% CI 9.8-10.0 ng/ml] versus 7.0 ng/ml [95% CI 6.9-7.0 ng/ml], respectively). Conclusions This study demonstrated that a DLT requires a 30% higher EC 50 of remifentanil than does an SLT to blunt haemodynamic responses during tracheal intubation when combined with a target-controlled infusion of propofol. Trial registration Clinicaltrials.gov identifier: NCT01542099.

  16. Development of a microplate coagulation assay for Factor V in human plasma.

    PubMed

    Tilley, Derek; Levit, Irina; Samis, John A

    2011-06-28

    Factor V (FV) in its activated form, FVa, is a critical regulator of thrombin generation during fibrin clot formation. There is a need of a simple, fast, and inexpensive microplate-based coagulation assay to measure the functional activity of FV in human plasma. The objective of this study was to develop a microplate-based assay that measures FV coagulation activity during clot formation in human plasma, which is currently not available. The FV assay requires a kinetic microplate reader to measure the change in absorbance at 405nm during fibrin formation in human plasma. The FV assay accurately measures the time, initial rate, and extent of fibrin clot formation in human plasma. The FV microplate assay is simple, fast, economical, sensitive to approx 24-80pM, and multiple samples may be analyzed simultaneously. All the required materials are commercially available. Standard curves of time or initial rate of fibrin clot formation vs FV activity in the 1-stage assay (Without activation by thrombin) may be used to measure FV activity in samples of human plasma. The assay was used to demonstrate that in nine patients with disseminated intravascular coagulation (DIC), the FV 1-stage, 2-stage (With activation by thrombin), and total (2-stage activity - 1-stage activity) activities were decreased, on average, by approximately 54%, 44%, and 42%, respectively, from prolonged clot times when compared to normal pooled human reference plasma (NHP). The results indicate that the FV in the DIC patient plasmas supported both a delayed and slower rate of fibrin clot formation compared with NHP; however, the extent of fibrin clot formation in the DIC patients remained largely unchanged from that observed with NHP. The FV microplate assay may be easily adapted to measure the activity of any coagulation factor using the appropriate factor-deficient plasma and clot initiating reagent. The microplate assay will find use in both research and clinical laboratories to provide measurement

  17. Development of a microplate coagulation assay for Factor V in human plasma

    PubMed Central

    2011-01-01

    Background Factor V (FV) in its activated form, FVa, is a critical regulator of thrombin generation during fibrin clot formation. There is a need of a simple, fast, and inexpensive microplate-based coagulation assay to measure the functional activity of FV in human plasma. The objective of this study was to develop a microplate-based assay that measures FV coagulation activity during clot formation in human plasma, which is currently not available. Methods The FV assay requires a kinetic microplate reader to measure the change in absorbance at 405nm during fibrin formation in human plasma. The FV assay accurately measures the time, initial rate, and extent of fibrin clot formation in human plasma. Results The FV microplate assay is simple, fast, economical, sensitive to approx 24-80pM, and multiple samples may be analyzed simultaneously. All the required materials are commercially available. Standard curves of time or initial rate of fibrin clot formation vs FV activity in the 1-stage assay (Without activation by thrombin) may be used to measure FV activity in samples of human plasma. The assay was used to demonstrate that in nine patients with disseminated intravascular coagulation (DIC), the FV 1-stage, 2-stage (With activation by thrombin), and total (2-stage activity - 1-stage activity) activities were decreased, on average, by approximately 54%, 44%, and 42%, respectively, from prolonged clot times when compared to normal pooled human reference plasma (NHP). The results indicate that the FV in the DIC patient plasmas supported both a delayed and slower rate of fibrin clot formation compared with NHP; however, the extent of fibrin clot formation in the DIC patients remained largely unchanged from that observed with NHP. Conclusions The FV microplate assay may be easily adapted to measure the activity of any coagulation factor using the appropriate factor-deficient plasma and clot initiating reagent. The microplate assay will find use in both research and

  18. Reciprocal coupling of coagulation and innate immunity via neutrophil serine proteases.

    PubMed

    Massberg, Steffen; Grahl, Lenka; von Bruehl, Marie-Luise; Manukyan, Davit; Pfeiler, Susanne; Goosmann, Christian; Brinkmann, Volker; Lorenz, Michael; Bidzhekov, Kiril; Khandagale, Avinash B; Konrad, Ildiko; Kennerknecht, Elisabeth; Reges, Katja; Holdenrieder, Stefan; Braun, Siegmund; Reinhardt, Christoph; Spannagl, Michael; Preissner, Klaus T; Engelmann, Bernd

    2010-08-01

    Blood neutrophils provide the first line of defense against pathogens but have also been implicated in thrombotic processes. This dual function of neutrophils could reflect an evolutionarily conserved association between blood coagulation and antimicrobial defense, although the molecular determinants and in vivo significance of this association remain unclear. Here we show that major microbicidal effectors of neutrophils, the serine proteases neutrophil elastase and cathepsin G, together with externalized nucleosomes, promote coagulation and intravascular thrombus growth in vivo. The serine proteases and extracellular nucleosomes enhance tissue factor- and factor XII-dependent coagulation in a process involving local proteolysis of the coagulation suppressor tissue factor pathway inhibitor. During systemic infection, activation of coagulation fosters compartmentalization of bacteria in liver microvessels and reduces bacterial invasion into tissue. In the absence of a pathogen challenge, neutrophil-derived serine proteases and nucleosomes can contribute to large-vessel thrombosis, the main trigger of myocardial infarction and stroke. The ability of coagulation to suppress pathogen dissemination indicates that microvessel thrombosis represents a physiological tool of host defense.

  19. Effect of Centrifuge Temperature on Routine Coagulation Tests.

    PubMed

    Yazar, Hayrullah; Özdemir, Fatma; Köse, Elif

    2018-01-01

    This study investigated the effects of cooled and standard centrifuges on the results of coagulation tests to examine the effects of centrifugation temperature. Equal-volume blood samples from each patient were collected at the same time intervals and subjected to standard (25°C) and cooled centrifugation (2-4°C). Subsequently, the prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (aPTT), fibrinogen, and D-dimer values were determined in runs with the same lot numbers in the same coagulation device using the Dia-PT R (PT and INR), Dia-PTT-liquid (aPTT), Dia-FIB (fibrinogen), and Dia-D-dimer kits, respectively. The study enrolled 771 participants. The PT was significantly (p < 0.018) higher in participants on anticoagulant therapy. The respective median values of the test parameters determined using the standard and cooled centrifuges were as follows: PT 10.30 versus 10.50 s; PT (INR) 1.04 versus 1.09 s; APTT 28.90 versus 29.40 s; fibrinogen 321.5 versus 322.1 mg/dL; and D-dimer 179.5 versus 168.7 µg FEU/mL. There were significant differences (p < 0.001) in the parameters between the values obtained with the standard and cooled centrifuges. Centrifuge temperature can have a significant effect on the results of coagulation tests. However, broad and specific disease-based studies are needed. © 2018 S. Karger AG, Basel.

  20. Immediate central and peripheral haemodynamic effects of a new vasodilating agent Pinacidil (P1134) in hypertensive man.

    PubMed

    Carlsen, J E; Kardel, T; Hilden, T; Tangø, M; Trap-Jensen, J

    1981-08-01

    The purpose of this study was to evaluate the immediate central and peripheral haemodynamic effects of a new vasodilating agent P 1134, in hypertensive man. After oral administration of 25 mg P 1134, the maximal haemodynamic changes were (mean +/- 1 SEM): mean blood pressure fell from 121.8 +/- 6.5 to 80.5 +/- 7.8 mmHg, heart rate increased 24.2 +/- 4.5 beats/min, cardiac output rose 2.9 +/- 0.3 1/min and forearm blood flow increased 1.0 +/- 0.1 ml/100 ml tissue/min. Stroke volume increased 17.0 +/- 2.1 ml and the inotropic state of the heart as judged from systolic time intervals increased. Total peripheral resistance and forearm vascular resistance were both reduced by approx. 50%. Linear correlations were found between the serum concentration of P 1134 and the change in mean blood pressure and total peripheral resistance. Changes in the other parameters mentioned above occurred progressively with changes in mean blood pressure and total peripheral resistance. It can be concluded that P 1134 is a very potent hypotensive agent with a haemodynamic profile identical to that seen with vasodilators with preferably act on precapillary resistance vessels. Potency and maximal efficacy exceeds that of hydralazine and seems like that of minoxidil. P 1134 is remarkably free from side-effects apart from causing water retention as all other vasodilators. It can be administered orally as well as intravenously. This makes P 1134 a very interesting compound in the treatment of moderate to severe hypertension, and further studies are well-founded.

  1. Retrospective analysis of the incidence of epidural haematoma in patients with epidural catheters and abnormal coagulation parameters.

    PubMed

    Gulur, P; Tsui, B; Pathak, R; Koury, K M; Lee, H

    2015-05-01

    Epidural haematoma is a rare but potentially catastrophic complication associated with epidural catheterization. The times of insertion and removal of epidural catheters are high-risk periods for epidural haematoma formation, especially with abnormal coagulation parameters. There is a lack of data on the incidence of epidural haematoma in patients with abnormal coagulation parameters. A retrospective analysis was undertaken from 2002 to 2009 on patients with an epidural catheter. Queries were performed on the coagulation parameters for the dates of placement and removal of the catheters and on all documented epidural haematoma cases. During the study period, 11 600 epidural catheters were placed. In the setting of abnormal coagulation parameters, 278 (2.4%) epidural catheters were placed and 351 (3%) were removed. Two epidural haematomas occurred; both patients had epidural catheters and spinal drains placed for vascular procedures with abnormal coagulation parameters after operatation. The haematomas occurred after removal of the catheters. Based on our study, the incidence of epidural haematoma in patients with abnormal coagulation parameters is 1 in 315 patients, with the lower limit of the 95% confidence interval at 87 and the upper limit at 2597. The risk of epidural haematoma is clearly elevated with abnormal coagulation parameters. Our data suggest that as the incidence of epidural haematoma with neuraxial access in patients with abnormal coagulation is not 100%, individual risk-benefit evaluations are warranted. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Quality of oral anticoagulation with phenprocoumon in regular medical care and its potential for improvement in a telemedicine-based coagulation service--results from the prospective, multi-center, observational cohort study thrombEVAL.

    PubMed

    Prochaska, Jürgen H; Göbel, Sebastian; Keller, Karsten; Coldewey, Meike; Ullmann, Alexander; Lamparter, Heidrun; Jünger, Claus; Al-Bayati, Zaid; Baer, Christina; Walter, Ulrich; Bickel, Christoph; ten Cate, Hugo; Münzel, Thomas; Wild, Philipp S

    2015-01-23

    The majority of studies on quality of oral anticoagulation (OAC) therapy with vitamin K-antagonists are performed with short-acting warfarin. Data on long-acting phenprocoumon, which is frequently used in Europe for OAC therapy and is considered to enable more stable therapy adjustment, are scarce. In this study, we aimed to assess quality of OAC therapy with phenprocoumon in regular medical care and to evaluate its potential for optimization in a telemedicine-based coagulation service. In the prospective observational cohort study program thrombEVAL we investigated 2,011 patients from regular medical care in a multi-center cohort study and 760 patients from a telemedicine-based coagulation service in a single-center cohort study. Data were obtained from self-reported data, computer-assisted personal interviews, and laboratory measurements according to standard operating procedures with detailed quality control. Time in therapeutic range (TTR) was calculated by linear interpolation method to assess quality of OAC therapy. Study monitoring was carried out by an independent institution. Overall, 15,377 treatment years and 48,955 international normalized ratio (INR) measurements were analyzed. Quality of anticoagulation, as measured by median TTR, was 66.3% (interquartile range (IQR) 47.8/81.9) in regular medical care and 75.5% (IQR 64.2/84.4) in the coagulation service (P <0.001). Stable anticoagulation control within therapeutic range was achieved in 63.8% of patients in regular medical care with TTR at 72.1% (IQR 58.3/84.7) as compared to 96.4% of patients in the coagulation service with TTR at 76.2% [(IQR 65.6/84.7); P = 0.001)]. Prospective follow-up of coagulation service patients with pretreatment in regular medical care showed an improvement of the TTR from 66.2% (IQR 49.0/83.6) to 74.5% (IQR 62.9/84.2; P <0.0001) in the coagulation service. Treatment in the coagulation service contributed to an optimization of the profile of time outside therapeutic range, a

  3. Adaptive force sonorheometry for assessment of whole blood coagulation.

    PubMed

    Mauldin, F William; Viola, Francesco; Hamer, Theresa C; Ahmed, Eman M; Crawford, Shawna B; Haverstick, Doris M; Lawrence, Michael B; Walker, William F

    2010-05-02

    Viscoelastic diagnostics that monitor the hemostatic function of whole blood (WB), such as thromboelastography, have been developed with demonstrated clinical utility. By measuring the cumulative effects of all components of hemostasis, viscoelastic diagnostics have circumvented many of the challenges associated with more common tests of blood coagulation. We describe a new technology, called sonorheometry, that adaptively applies acoustic radiation force to assess coagulation function in WB. The repeatability (precision) of coagulation parameters was assessed using citrated WB samples. A reference range of coagulation parameters, along with corresponding measurements from prothrombin time (PT) and partial thromboplastin time (PTT), were obtained from WB samples of 20 healthy volunteers. In another study, sonorheometry monitored anticoagulation with heparin (0-5 IU/ml) and reversal from varied dosages of protamine (0-10 IU/ml) in heparinized WB (2 IU/ml). Sonorheometry exhibited low CVs for parameters: clot initiation time (TC1), <7%; clot stabilization time (TC2), <6.5%; and clotting angle (theta), <3.5%. Good correlation was observed between clotting times, TC1 and TC2, and PTT (r=0.65 and 0.74 respectively; n=18). Linearity to heparin dosage was observed with average linearity r>0.98 for all coagulation parameters. We observed maximum reversal of heparin anticoagulation at protamine to heparin ratios of 1.4:1 from TC1 (P=0.6) and 1.2:1 from theta (P=0.55). Sonorheometry is a non-contact method for precise assessment of WB coagulation. Copyright 2010 Elsevier B.V. All rights reserved.

  4. Effect of rivaroxaban on blood coagulation using the viscoelastic coagulation test ROTEM™.

    PubMed

    Casutt, M; Konrad, C; Schuepfer, G

    2012-11-01

    This study investigated the influence of the oral direct inhibitor of factor Xa rivaroxaban on blood coagulation measured by rotation thrombelastometry ROTEM™. Blood was obtained from 11 healthy male volunteers before and 2.5 h after oral administration of 10 mg rivaroxaban. In addition to standard coagulation tests clot formation was measured by ROTEM™ analyzing extrinsic (Extem) and intrinsic thrombelastometry (Intem). Significant differences to the baseline values were found in the Extem clotting time (Extem-CT, 58 ± 9 s and 87 ± 17 s, p < 0.01), Intem-CT (194 ± 26 s and 239 ± 43 s; p = 0.02), prothrombin time (PT, 86 ± 9% and 67 ± 7%; p < 0.01) and activated partial thromboplastin time (aPTT, 28 ± 1 s and 35 ± 2 s; p < 0.01). There was a low correlation between Extem-CT and PT as well as between Intem-CT and aPTT before and after rivaroxaban intake. The receiver operating characteristic curve (ROC) analysis determined aPTT to be the most appropriate parameter for the prediction of rivaroxaban-induced anticoagulation, Intem-CT and Extem-CT proved to be moderate tests and PT had no significance in the prediction of rivaroxaban-induced anticoagulation. Of utmost clinical importance was the fact that rivaroxaban treated patients could still show normal ROTEM™ values. Thus, ROTEM™ cannot be a suitable test method to exclude inhibition of blood coagulation by rivaroxaban.

  5. Metals in airpollution particles decrease whole blood coagulation time

    EPA Science Inventory

    The mechanism underlying the pro-coagulative effect of air pollution particle exposure is not known. We tested the postulate that 1) the soluble fraction ofan air pollution particle can affect whole blood coagulation time and 2) metals included in the soluble fraction are respons...

  6. Novel Al-doped carbon nanotubes with adsorption and coagulation promotion for organic pollutant removal.

    PubMed

    Kang, Dongjuan; Yu, Xiaolin; Ge, Maofa; Xiao, Feng; Xu, Hui

    2017-04-01

    Al-doped carbon nanotubes (Al-doped CNTs) were prepared as a multifunctional integrated material of adsorbent and coagulant aid for organic pollutant removal from aqueous solution. It was observed that aluminum species were dispersed homogeneously on the surface of CNTs, and mainly anchored onto defect structures of the CNTs. The introduction of aluminium efficiently improved adsorption ability for methyl orange (MO) onto the CNTs, and maximum adsorption capacity calculated from the Langmuir isotherm model can reach 69.7mg/g. The MO adsorption kinetics can be better described by the pseudo-second-order and pore diffusion kinetic models, and the diffusion of MO anions into pores of the Al-doped CNT adsorbent should be the rate-determining step. Thermodynamic analyses indicated that the adsorption of MO onto Al-CNTs-2.0 was endothermic and spontaneous. Moreover, adsorption capacity for MO on the Al-doped CNTs was evidently dependent on the CNT dose, solution pH and adsorbent dose. From the perspective of low-cost and multifunctional, suspension obtained during the Al-doped CNT adsorbent preparation, was tested as coagulant to remove humic acid (HA). A significant observation is that the suspension exhibited an excellent coagulation performance for HA, because abundant aluminous polymer and Al-doped CNTs existed in the suspension. Copyright © 2016. Published by Elsevier B.V.

  7. Up-scaling of tannin-based coagulants for wastewater treatment: performance in a water treatment plant.

    PubMed

    Grenda, Kinga; Arnold, Julien; Gamelas, José A F; Rasteiro, Maria G

    2018-06-21

    Tannin extracts from the bark of Acacia mearnsii and wood of Schinopsis balansae, commonly known as Quebracho, were employed. These were modified at laboratory sale via the Mannich aminomethylation with formaldehyde and dimethylamine hydrochloride. Some reaction conditions were varied, namely the formaldehyde dosage and reaction time, while keeping the Mannich solution activation time constant, and their influence on the shear viscosity of the created bio-coagulants was evaluated. The effect of the final pH of the products on their shear viscosity was also analyzed. Up-scaling of the Mannich reaction for tannin from South Africa was performed and the procedure developed at 1-L scale was reproducible in upscaled conditions. One example of a modified South Africa tannin and the modified Quebracho tannin was subsequently selected for the treatment of an industrial wastewater and tested for color and turbidity reduction in jar tests. The effluent treatment was carried out in a single and dual system with cationic synthetic flocculation agents of different charge degree. Good turbidity and decoloration results (93 and 89% reduction, respectively) were obtained with the simultaneous introduction of a cationic, 40% charged polyacrylamide, with minimal dosage (5 ppm) of the latter additive. The tannin-based coagulant from Acacia mearnsii was successfully applied in dual system with cationic polyacrylamide flocculant for industrial wastewater treatment at pilot plant scale. It was shown to satisfactorily treat the water and generate less sludge.

  8. Charging and coagulation of radioactive and nonradioactive particles in the atmosphere

    DOE PAGES

    Kim, Yong-ha; Yiacoumi, Sotira; Nenes, Athanasios; ...

    2016-01-01

    Charging and coagulation influence one another and impact the particle charge and size distributions in the atmosphere. However, few investigations to date have focused on the coagulation kinetics of atmospheric particles accumulating charge. This study presents three approaches to include mutual effects of charging and coagulation on the microphysical evolution of atmospheric particles such as radioactive particles. The first approach employs ion balance, charge balance, and a bivariate population balance model (PBM) to comprehensively calculate both charge accumulation and coagulation rates of particles. The second approach involves a much simpler description of charging, and uses a monovariate PBM and subsequentmore » effects of charge on particle coagulation. The third approach is further simplified assuming that particles instantaneously reach their steady-state charge distributions. It is found that compared to the other two approaches, the first approach can accurately predict time-dependent changes in the size and charge distributions of particles over a wide size range covering from the free molecule to continuum regimes. The other two approaches can reliably predict both charge accumulation and coagulation rates for particles larger than about 0.04 micrometers and atmospherically relevant conditions. These approaches are applied to investigate coagulation kinetics of particles accumulating charge in a radioactive neutralizer, the urban atmosphere, and an atmospheric system containing radioactive particles. Limitations of the approaches are discussed.« less

  9. Use of combined coagulation-adsorption process as pretreatment of landfill leachate

    PubMed Central

    2013-01-01

    Landfill leachate is an important pollution factor resulting from municipal landfill sites. Physical and chemical processes are the better option for pretreatment or full treatment of landfill leachate. This article presents a combination of pre-treatment method (coagulation and adsorption) for leachate collected from municipal solid waste open dumping site. Physico chemical characteristics of stabilized and fresh leachate were examined. Coagulation process was examined by using alum and ferric chloride. A low cost adsorbent, fly ash was used for adsorption studies. Coagulation studies were carried out for fresh and stabilized leachate. Adsorption studies have been conducted for alum pre-treated stabilized leachate. Effect of coagulant dose, adsorbent dose, pH and contact time were carried out. The effective optimum coagulant dosages were 0.6 g/L and 0.7 g/L for alum and ferric chloride respectively for stabilized leachate and incase of fresh leachate 0.8 g/L and 0.6 g/L for alum and ferric chloride respectively. For the alum pretreated stabilized leachate, the maximum COD removal is 28% using fly ash adsorbent with equilibrium time of 210 min and optimum dose of 6 g/L. Overall COD removal efficiency of 82% was obtained by coagulation using alum and adsorption using fly ash for stabilized leachate. The results obtained showed that combined coagulation and adsorption process can be used effectively for stabilized leachate treatment. PMID:23517661

  10. An in vitro analysis of the effect of acidosis on coagulation in chronic disease states - a thromboelastograph study.

    PubMed

    White, Hayden; Bird, Robert; Sosnowski, Kellie; Jones, Mark

    2016-06-01

    Thrombosis is a complication of many chronic illnesses. Chronic obstructive pulmonary disease (COPD) and diabetes mellitus are common medical conditions frequently associated with a hypercoagulable state. Acidaemia has been shown to reduce coagulation. COPD and diabetes mellitus during acute deterioration can present with a severe acidaemia. The impact of this acidaemia on coagulation is poorly studied. Patients presenting with a diagnosis of diabetic ketoacidosis or type II respiratory failure from COPD and a pH of less than 7.2 were included in our study. A coagulation screen and a thromboelastograph (TEG) were performed on admission and 24 hours later. The mean pH on admission was 7.07 and mean base excess was -16.3. The activated partial thromboplastin time was associated with pH change but remained within the normal range (26-41 s). All other coagulation and TEG parameters failed to show evidence of association (p>0.05). In the two models of non-haemorrhagic acidosis investigated, coagulation was not altered by the changes in pH. More work is needed to understand the complex relationship between factors affecting coagulation in individual disease processes. © 2016 Royal College of Physicians.

  11. In-line pressure-flow module for in vitro modelling of haemodynamics and biosensor validation

    NASA Technical Reports Server (NTRS)

    Koenig, S. C.; Schaub, J. D.; Ewert, D. L.; Swope, R. D.; Convertino, V. A. (Principal Investigator)

    1997-01-01

    An in-line pressure-flow module for in vitro modelling of haemodynamics and biosensor validation has been developed. Studies show that good accuracy can be achieved in the measurement of pressure and of flow, in steady and pulstile flow systems. The model can be used for development, testing and evaluation of cardiovascular-mechanical-electrical anlogue models, cardiovascular prosthetics (i.e. valves, vascular grafts) and pressure and flow biosensors.

  12. Dose Responses of Ibuprofen In Vitro on Platelet Aggregation and Coagulation in Human and Pig Blood Samples.

    PubMed

    Martini, Wenjun Z; Rodriguez, Cassandra M; Deguzman, Rodolfo; Guerra, Jessica B; Martin, Angela K; Pusateri, Anthony E; Cap, Andrew P; Dubick, Michael A

    2016-05-01

    Ibuprofen is commonly used by warfighters in the deployed environment. This study investigated its dose effects on in vitro coagulation in human and pig blood. Blood samples were collected from 6 normal volunteers and 6 healthy pigs and processed to make platelet-adjusted samples (100 × 10(3)/μL, common transfusion trigger in trauma). Ibuprofen was added to the samples at concentrations of 0 μg/mL (control), the concentration from the highest recommended oral dose (163 μg/mL, 1×), and 2×, 4×, 8×, 10×, 12×, 16×, and 20×. Platelet aggregation by Chrono-Log aggregometer and coagulation by rotational thrombelastogram (Rotem) were assessed at 15 minutes after the addition of ibuprofen. A robust inhibition of ibuprofen on arachidonic acid-induced platelet aggregation was observed at all doses tested in human or pig blood. Collagen-stimulated platelet aggregation was inhibited starting at 1× in human blood and 4× in pig blood. Rotem measurements were similarly compromised in pig and human blood starting at 16×, except clot formation time was prolonged at 1× in human blood (all p < 0.05). Ibuprofen inhibited platelet aggregation at recommended doses, and compromised coagulation at higher doses. Human blood was more sensitive to ibuprofen inhibition. Further effort is needed to investigate ibuprofen dose responses on coagulation in vivo. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  13. Bladder perforation owing to a unipolar coagulating device.

    PubMed

    Pakter, J; Budnick, L D

    1981-09-15

    A report on a patient who sustained a burn and perforation of the urinary bladder from visible sparks emanating from a unipolar coagulating device during the couse of laparoscopic sterilization is presented. It is the first report of urinary bladder burns using a unipolar coagulating device. A 24-year-old woman, gravida 10, para 3, abortus 7, underwent a laparoscopic sterilization with a unipolar coagulating device. As the physician was finishing the coagulation, a spark from the device caused a 1-2 cm burn with a central area of perforation into the urinary bladder. Conservative treatment was recommended, and consisted of Foley catheterization and drainage for 5 days. Initial urine culture revealed Klebsiella species, and oral ampicillin was prescribed. Hematuria was noted throughout the patient's hospitalization, and blood clots were present in the urine on Day 2 postoperation. The patient had no abdominal or flank pain, was afebrile, and had a stable hemoglobin level during the hospital stay. Cystography was performed on Day 5 postoperatively and demonstrated no perforation. Foley catheter was removed. Patient was discharged 2 days later and remains in good health 3 months postoperatively.

  14. Epsilon-aminocaproic Acid for Treatment of Fibrinolysis during Liver Transplantation

    PubMed Central

    Kang, Yoogoo; Lewis, Jessica H.; Navalgund, Ashok; Russell, Michael W.; Bontempo, Franklin A.; Niren, Lawrence S.; Starzl, Thomas E.

    2010-01-01

    In 97 adult patients receiving liver transplants, the coagulation system was monitored by thrombelastography and by coagulation profile including PT; aPTT; platelet count; level of factors I, II, V, VII, VIII, IX, X, XI, and XII; fibrin degradation products; ethanol gel test; protamine gel test; and euglobulin lysis time. Preoperatively, fibrinolysis defined as a whole blood clot lysis index of less than 80% was present in 29 patients (29.9%), and a euglobulin lysis time of less than 1 h was present in 13 patients. Fibrinolysis increased progressively during surgery in 80 patients (82.5%) and was most severe on reperfusion of the graft liver in 33 patients (34%). When whole blood clot lysis (F < 180 min) was observed during reperfusion of the graft liver, blood coagulability was tested by thrombelastography using both a blood sample treated in vitro with ε-aminocaproic acid (0.09%) and an untreated sample. Blood treated with ε-aminocaproic acid showed improved coagulation without fibrinolytic activity in all 74 tests. When whole blood clot lysis time was less than 120 min, generalized oozing occurred, and the effectiveness of ε-aminocaproic acid was demonstrated in vitro during the pre-anhepatic and post-anhepatic stages, ε-aminocaproic acid (1 g, single intravenous dose) was administered. In all 20 patients treated with ε-aminocaproic acid, fibrinolytic activity disappeared; whole blood clot lysis was not seen on thrombelastography during a 5-h observation period, and whole blood clot lysis index improved from 28.5 ± 29.5% to 94.8 ± 7.4% (mean ± SD, P < 0.001). None of the treated patients had hemorrhagic or thrombotic complications. In patients undergoing liver transplantation, the judicious use of a small dose of ε-aminocaproic acid, when its efficacy was confirmed in vitro, effectively treated the severe fibrinolysis without clinical thrombotic complications. PMID:3296855

  15. Coagulant Recovery from Water Treatment Residuals: A Review of Applicable Technologies

    PubMed Central

    Keeley, J.; Jarvis, P.; Judd, S. J.

    2014-01-01

    Conventional water treatment consumes large quantities of coagulant and produces even greater volumes of sludge. Coagulant recovery (CR) presents an opportunity to reduce both the sludge quantities and the costs they incur, by regenerating and purifying coagulant before reuse. Recovery and purification must satisfy stringent potable regulations for harmful contaminants, while remaining competitive with commercial coagulants. These challenges have restricted uptake and lead research towards lower-gain, lower-risk alternatives. This review documents the context in which CR must be considered, before comparing the relative efficacies and bottlenecks of potential technologies, expediting identification of the major knowledge gaps and future research requirements. PMID:26064036

  16. Review of Coagulation Technology for Removal of Arsenic: Case of Chile

    PubMed Central

    2006-01-01

    Coagulation technology has been used since 1970 in northern Chile for removing arsenic from drinking-water. This experience suggests that coagulation is an effective technology for the removal of arsenic. It is currently possible to reduce arsenic from 400 μg/L to 10 μg/L at a rate of 500 L/sec, assuming pH, oxidizing and coagulation agents are strictly controlled. The Chilean experience with the removal of arsenic demonstrates that the water matrix dictates the selection of the arsenic-removal process. This paper presents a summary of the process, concepts, and operational considerations for the use of coagulation technology for removal of arsenic in Chile. PMID:17366767

  17. Dust coagulation. [in interstellar medium observed in stellar envelopes and planetary disks

    NASA Technical Reports Server (NTRS)

    Chokshi, Arati; Tielens, A. G. G. M.; Hollenbach, D.

    1993-01-01

    The microphysics of coagulation between two, colliding, smooth, spherical grains in the elastic limit is investigated, and the criteria for sticking as a function of particle sizes, collision velocities, elastic properties, and binding energy are calculated. Critical relative velocities for coagulation were evaluated as a function of grain sizes for solicate, icy, and carbonaceous grains. It is concluded that efficient coagulation requires coverage of grain cores by an icy grain mantle. In this case, coagulation leads to only a doubling of the mass of a large grain within a dense core lifetime. It is concluded that coagulation can have a dramatic effect on the visible and, particularly, the UV portion of the extinction curve in dense clouds and on their IR spectrum.

  18. Prediction of coagulation and flocculation processes using ANN models and fuzzy regression.

    PubMed

    Zangooei, Hossein; Delnavaz, Mohammad; Asadollahfardi, Gholamreza

    2016-09-01

    Coagulation and flocculation are two main processes used to integrate colloidal particles into larger particles and are two main stages of primary water treatment. Coagulation and flocculation processes are only needed when colloidal particles are a significant part of the total suspended solid fraction. Our objective was to predict turbidity of water after the coagulation and flocculation process while other parameters such as types and concentrations of coagulants, pH, and influent turbidity of raw water were known. We used a multilayer perceptron (MLP), a radial basis function (RBF) of artificial neural networks (ANNs) and various kinds of fuzzy regression analysis to predict turbidity after the coagulation and flocculation processes. The coagulant used in the pilot plant, which was located in water treatment plant, was poly aluminum chloride. We used existing data, including the type and concentrations of coagulant, pH and influent turbidity, of the raw water because these types of data were available from the pilot plant for simulation and data was collected by the Tehran water authority. The results indicated that ANNs had more ability in simulating the coagulation and flocculation process and predicting turbidity removal with different experimental data than did the fuzzy regression analysis, and may have the ability to reduce the number of jar tests, which are time-consuming and expensive. The MLP neural network proved to be the best network compared to the RBF neural network and fuzzy regression analysis in this study. The MLP neural network can predict the effluent turbidity of the coagulation and the flocculation process with a coefficient of determination (R 2 ) of 0.96 and root mean square error of 0.0106.

  19. Comparison of the effects of a balanced crystalloid-based and a saline-based tetrastarch solution on canine whole blood coagulation and platelet function.

    PubMed

    Reuteler, Annina; Axiak-Flammer, Shannon; Howard, Judith; Adamik, Katja-Nicole

    2017-01-01

    To evaluate the effects of a 6% hydroxyethyl starch (130/0.42) solution in either a buffered, electrolyte-balanced (HES-BAL), or a saline (HES-SAL) carrier solution on canine platelet function and whole blood coagulation. Prospective, randomized study. University teaching hospital. Thirty-seven client-owned dogs undergoing general anesthesia for arthroscopy or imaging studies. Dogs received a 15 mL/kg intravenous bolus of HES-SAL (n = 13), HES-BAL (n = 14), or a modified Ringer's solution (n = 10) over 30-40 minutes. Coagulation was analyzed using a Platelet Function Analyzer-100 (closure time [Ct PFA ]), and whole blood thromboelastometry (ROTEM) with extrinsically (ex-tem and fib-tem) and intrinsically (in-tem) activated assays, which assessed clotting time (CT), clot formation time (CFT), maximal clot firmness (MCF), and lysis index (LI). Coagulation samples were assayed prior to fluid administration (T0), and 5 minutes (T1), and 3 hours (T2) following fluid bolus administration, respectively. Both HES solutions resulted in impaired platelet function as indicated by a significant prolongation of Ct PFA at T1 as compared to T0, but which resolved by T2. An IV bolus of Ringer's solution did not alter platelet function. In both HES groups, whole blood coagulation was significantly impaired at T1 as indicated by a significant increase in in-tem CFT, and a significant decrease in ex-tem, in-tem, and fib-tem MCF compared to T0. Furthermore, a significant increase in ex-tem CFT at T1 compared to T0 was found in the HES-SAL group. With the exception of in-tem MCF after HES-BAL, these effects were not present at T2. No significant differences were found in Ct PFA or any ROTEM variable at any time point between HES-SAL and HES-BAL. Administration of a single bolus of 15 mL/kg 6% HES 130/0.42 results in significant but short-lived impairment of canine platelet function and whole blood coagulation, regardless of carrier solution. © Veterinary Emergency and Critical Care

  20. Changes in the human blood coagulating system during prolonged hypokinesia

    NASA Technical Reports Server (NTRS)

    Filatova, L. M.; Anashkin, O. D.

    1978-01-01

    Changes in the coagulating system of the blood were studied in six subjects during prolonged hypokinesia. Thrombogenic properties of the blood rose in all cases on the 8th day. These changes are explained by stress reaction due to unusual conditions for a healthy person. Changes in the blood coagulating system in the group subjected to physical exercise and without it ran a practically parallel course. Apparently physical exercise is insufficient to prevent such changes that appear in the coagulating system of the blood during prolonged hypokinesia.

  1. What Is Disseminated Intravascular Coagulation?

    MedlinePlus

    ... leading to DIC. These diseases and conditions include: Sepsis (an infection in the bloodstream) Surgery and trauma ... intravascular coagulation (DIC). These diseases and conditions include: Sepsis (an infection in the bloodstream) Surgery and trauma ...

  2. Removal of organic impurities in waste glycerol from biodiesel production process through the acidification and coagulation processes.

    PubMed

    Xie, Qiao-Guang; Taweepreda, Wirach; Musikavong, Charongpun; Suksaroj, Chaisri

    2012-01-01

    Treatment of waste glycerol, a by-product of the biodiesel production process, can reduce water pollution and bring significant economic benefits for biodiesel facilities. In the present study, hydrochloric acid (HCl) was used as acidification to convert soaps into salts and free fatty acids which were recovered after treatment. The pH value, dosages of polyaluminum chloride (PACl) and dosage of polyacrylamide (PAM) were considered to be the factors that can influence coagulation efficiency. The pH value of waste glycerol was adjusted to a pH range of 3-9. The PACl and PAM added were in the range of 1-6 g/L and 0.005-0.07 g/L. The results showed best coagulation efficiency occurs at pH 4 when dosage of PACl and PAM were 2 and 0.01 g/L. The removal of chemical oxygen demand (COD), biochemical oxygen demand (BOD(5)), total suspended solids (TSS) and soaps were 80, 68, 97 and 100%, respectively. The compositions of organic matters in the treated waste glycerol were glycerol (288 g/L), methanol (3.8 g/L), and other impurities (0.3 g/L).

  3. Acid-Base Homeostasis

    PubMed Central

    Nakhoul, Nazih; Hering-Smith, Kathleen S.

    2015-01-01

    Acid-base homeostasis and pH regulation are critical for both normal physiology and cell metabolism and function. The importance of this regulation is evidenced by a variety of physiologic derangements that occur when plasma pH is either high or low. The kidneys have the predominant role in regulating the systemic bicarbonate concentration and hence, the metabolic component of acid-base balance. This function of the kidneys has two components: reabsorption of virtually all of the filtered HCO3− and production of new bicarbonate to replace that consumed by normal or pathologic acids. This production or generation of new HCO3− is done by net acid excretion. Under normal conditions, approximately one-third to one-half of net acid excretion by the kidneys is in the form of titratable acid. The other one-half to two-thirds is the excretion of ammonium. The capacity to excrete ammonium under conditions of acid loads is quantitatively much greater than the capacity to increase titratable acid. Multiple, often redundant pathways and processes exist to regulate these renal functions. Derangements in acid-base homeostasis, however, are common in clinical medicine and can often be related to the systems involved in acid-base transport in the kidneys. PMID:26597304

  4. Clay-catalyzed reactions of coagulant polymers during water chlorination

    USGS Publications Warehouse

    Lee, J.-F.; Liao, P.-M.; Lee, C.-K.; Chao, H.-P.; Peng, C.-L.; Chiou, C.T.

    2004-01-01

    The influence of suspended clay/solid particles on organic-coagulant reactions during water chlorination was investigated by analyses of total product formation potential (TPFP) and disinfection by-product (DBP) distribution as a function of exchanged clay cation, coagulant organic polymer, and reaction time. Montmorillonite clays appeared to act as a catalytic center where the reaction between adsorbed polymer and disinfectant (chlorine) was mediated closely by the exchanged clay cation. The transition-metal cations in clays catalyzed more effectively than other cations the reactions between a coagulant polymer and chlorine, forming a large number of volatile DBPs. The relative catalytic effects of clays/solids followed the order Ti-Mont > Fe-Mont > Cu-Mont > Mn-Mont > Ca-Mont > Na-Mont > quartz > talc. The effects of coagulant polymers on TPFP follow the order nonionic polymer > anionic polymer > cationic polymer. The catalytic role of the clay cation was further confirmed by the observed inhibition in DBP formation when strong chelating agents (o-phenanthroline and ethylenediamine) were added to the clay suspension. Moreover, in the presence of clays, total DBPs increased appreciably when either the reaction time or the amount of the added clay or coagulant polymer increased. For volatile DBPs, the formation of halogenated methanes was usually time-dependent, with chloroform and dichloromethane showing the greatest dependence. ?? 2003 Elsevier Inc. All rights reserved.

  5. [Comprehensive monitoring of cerebral haemodynamics during surgical interventions on brachiocephalic arteries].

    PubMed

    Ignat'ev, I M; Bredikhin, R A; Falina, T G; Vinogradova, V V; Khismatullina, L I

    2010-01-01

    The authors analysed a total of 152 surgical interventions on the brachiocephalic arteries (BCAs) performed in 142 patients. All the patients were subjected to intraoperative monitoring of cerebral haemodynamics by means of transcranial Doppler (TCD) ultrasonography simultaneously accompanied by electroencephalography (EEG). Additionally, the state of the reconstructed carotid arteries was controlled by means of ultrasonographic duplex scanning (USDS). Comparing the findings of the TCD recording and EEG made it possible to single out 5 groups of the operated patients. The EEG technique turned out to have more informative value as compared with TCD ultrasonography in determining the degree of cerebral ischaemia during clamping of the carotid arteries (CAs). Nine (5.9%) patients demonstrated lower tolerance of the brain to ischaemia, and the operation on the BCA was performed with the use of a temporal intraluminal bypass graft. Microembolic signals (MES) were registered in 54.6% of cases. Single MES were detected in six patients, sporadic MES--in 53, and multiple MES--in 24. Mention should be made that the--MES associated with the placement of the bypass graft appeared to be multiple and were registered in all the operated patients. Diffusion-weighted magnetic resonance tomography revealed fresh foci of lacunar cerebral infarctions in 14 (25%) of the 56 patients thus examined. Intraoperative USDS of the reconstructed carotid arteries revealed floatation of the residual remnants of the intima in two patients, which was the cause of a repeat intervention. Combined monitoring of cerebral haemodynamics makes it possible to timely prevent cerebral ischaemia, to narrow the indications for placement of an intraluminal bypass graft, and to dramatically decrease the rate of postoperative complications.

  6. Opposite effects of Agrimonia pilosa Ledeb aqueous extracts on blood coagulation function

    PubMed Central

    Yuan, Wufeng; Jiang, Lei; Wang, Huan

    2017-01-01

    Background Agrimonia pilosa Ledeb (APL) has showed anticoagulant and antithrombotic activities in some studies, whereas its actual effects on blood coagulation are still unclear. This study was designed to observe the in vitro effects of APL aqueous extracts on blood coagulation, as well as to investigate the underlying mechanisms. Methods Studies were divided into four groups: 0, 4, 20, and 80 g/L of APL aqueous extracts mixed with plasma or whole blood samples. Clotting time of whole blood, plasma coagulation tests, activities of plasma coagulation factors, plasma calcium ion, platelet aggregation test, and platelet fibrinogen receptor as well as the blood viscosity were measured. Results It was observed that the APL aqueous extracts in 4 g/L significantly prolonged the whole blood clotting time and activated partial thromboplastin time, shortened prothrombin time, decreased activities of coagulation factor VIII, IX and XI, and levels of platelet aggregation and fibrinogen receptor expression. However, coagulation factor VII activity, and blood viscosity were increased after the extracts treatment. And the effects of APL extracts were in a concentration-dependent manner (0–80 g/L). Conclusions The results suggest that APL aqueous extracts have a total anticoagulant activity, whereas they exhibit opposite effects of greater anticoagulant activity than pro-coagulant activity. PMID:28480193

  7. Optimization of composite coagulant made from polyferric chloride and tapioca starch in landfill leachate treatment

    NASA Astrophysics Data System (ADS)

    Shaylinda, M. Z. N.; Hamidi, A. A.; Mohd, N. A.; Ariffin, A.; Irvan, D.; Hazreek, Z. A. M.; Nizam, Z. M.

    2018-04-01

    In this research, the performance of polyferric chloride and tapioca flour as composite coagulants for partially stabilized leachate was investigated. Response surface methodology (RSM) was used to optimize the coagulation and flocculation process of partially stabilized leachate. Central composite design a standard design tool in RSM was applied to evaluate the interactions and effects of dose and pH. Dose 0.2 g/L Fe and pH 4.71 were the optimum value suggested by RSM. Experimental test based on the optimum condition, resulted in 95.9%, 94.6% and 50.4% of SS, color and COD removals, respectively. The percentage difference recorded between experimental and model responses was <5%. Therefore, it can be concluded that RSM was an appropriate optimization tool for coagulation and flocculation process.

  8. Effects of oversulfated and fucosylated chondroitin sulfates on coagulation. Challenges for the study of anticoagulant polysaccharides.

    PubMed

    Fonseca, Roberto J C; Oliveira, Stephan-Nicollas M C G; Pomin, Vitor H; Mecawi, André S; Araujo, Iracema G; Mourão, Paulo A S

    2010-05-01

    We report the effects of a chemically oversulfated chondroitin sulfate and a naturally fucosylated chondroitin sulfate on the coagulation system. The former has been recently identified as a contaminant of heparin preparations and the latter has been proposed as an alternative anticoagulant. The mechanism of action of these polymers on coagulation is complex and target different components of the coagulation system. They have serpin-independent anticoagulant activity, which preponderates in plasma. They also have serpin-dependent anticoagulant activity but differ significantly in the target coagulation protease and preferential serpin. Their anticoagulant effects differ even more markedly when tested as inhibitors of coagulation proteases using plasma as a source of serpins. It is possible that the difference is due to the high availability of fucosylated chondroitin sulfate whereas oversulfated chondroitin sulfate has strong unspecific binding to plasma protein and low availability for the binding to serpins. When tested using a venous thrombosis experimental model, oversulfated chondroitin sulfate is less potent as an antithrombotic agent than fucosylated chondroitin sulfate. These highly sulfated chondroitin sulfates activate factor XII in in vitro assays, based on kallikrein release. However, only fucosylated chondroitin sulfate induces hypotension when intravenously injected into rats. In conclusion, the complexity of the regulatory mechanisms involved in the action of highly sulfated polysaccharides in coagulation requires their analysis by a combination of in vitro and in vivo assays. Our results are relevant due to the urgent need for new anticoagulant drugs or alternative sources of heparin.

  9. Removal of cadmium from contaminated Lentinula edodes by optimized complexation and coagulation.

    PubMed

    Wang, Yi; Wang, Chen; Cheng, Wei; Bian, Yinbing; Guo, Peng

    2017-03-01

    Heavy metal pollution is a serious problem for Lentinula edodes ; however, the treatment of contaminated L. edodes has seldom been studied. This study investigated the removal of cadmium (Cd) from contaminated L. edodes and its lentinan by complexation and coagulation. Some influencing factors, such as pH, medical dosage, and preoxidation were examined. Cd complexation from contaminated L .  edodes was shown to be more efficient under acidic conditions (pH 5.0), with a clearance rate of 80.47% in 25 mmol/L EDTA and 78.45% in 25 mmol/L sodium citrate. The Cd content in the lentinan of the contaminated L. edodes was markedly lower than that in the powdered mushroom (2.77 mg/kg vs. 19.49 mg/kg) and was easier to remove. The maximum Cd clearance rate (96.3%) for lentinan was obtained using an optimized process that involved preoxidation with 0.5 mg/L KMnO 4 , complexing with 25 mmol/L EDTA and 25 mmol/L sodium citrate, and coagulation with 50 mg/L activated carbon (AC) at pH 10.0.

  10. [Comparison of thromboelastography and routine coagulation tests for evaluation of blood coagulation function in patients].

    PubMed

    Chen, Guan-Yi; Ou Yang, Xi-Lin; Wu, Jing-Hui; Wang, Li-Hua; Yang, Jin-Hua; Gu, Li-Nan; Lu, Zhu-Jie; Zhao, Xiao-Zi

    2015-04-01

    To investigate the correlation and consistency between thromboelastography(TEG) and routine coagulation tests, and to evaluate the value of the two methods in determining the blood coagulation of patients. The TEG, routine coagulation tests and platelet counts of 182 patients from the Intensive Care Unit(ICU) and Department of Gastroenterology in our hospital from January to September 2014 were performed and analyzed retrospectively for their correlation, Kappa identity test analysis and chi-square test, and the diagnostic sensitivity and specificity of both methods in the patients with bleeding were evaluated. The TEG R time and PT, R time and APTT showed a linear dependence (P<0.01). The relationship between the TEG K value, α-Angle, MA and Fibrinogen showed a linear dependence (P<0.001). And the relationship between the TEG K value, α-Angle, MA and the platelet count were in a linear dependent way (P<0.001). The Kappa values of the TEG R time with PT and APTT were 0.038 (P>0.05) and 0.061 (P>0.05), respectively. The chi-square test values of the TEG R time with PT and APTT were 35.309 (P<0.001) and 15.848 (P<0.001), respectively. The Fibrinogen and the TEG K value, α-Angle, MA value had statistical significance (P<0.001), with a Kappa value of 0.323, 0.288 and 0.427, respectively. The chi-square test values between Fibrinogen and the TEG K value, α-Angle, MA value were not statistically significant, with X2=1.091 (P=0.296), X2=1.361 (P=0.243), X2=0.108 (P=0.742). The Kappa values of the platelet count and the TEG K value, α-Angle, MA value were 0.379, 0.208 and 0.352, respectively, which were also statistically significant difference (P<0.001). The chi-square test values between the platelet count and the TEG K value, α-Angle, MA value showed a statistically significant difference (P<0.001), with X2=37.5, X2=37.23, X2=26.630. The diagnostic sensitivity of the two methods for the patients with bleeding was less than 50%. There was a significant correlation

  11. Influential factors of formation kinetics of flocs produced by water treatment coagulants.

    PubMed

    Wu, Chunde; Wang, Lin; Hu, Bing; Ye, Jian

    2013-05-01

    The growth rate and size of floc formation is of great importance in water treatment especially in coagulation process. The floc formation kinetics and the coagulation efficiency of synthetic water were investigated by using an on-line continuous optical photometric dispersion analyze and the analysis of water quality. Experimental conditions such as alum dosage, pH value for coagulation, stirring intensity and initial turbidity were extensively examined. The photometric dispersion analyze results showed that coagulation of kaolin suspensions with two coagulants (alum and polyaluminium chloride) could be taken as a two-phase process: slow and rapid growth periods. Operating conditions with higher coagulant doses, appropriate pH and average shear rate might be particularly advantageous. The rate of overall floc growth was mainly determined by a combination of hydraulic and water quality conditions such as pH and turbidity. The measurement of zeta potential indicates that polyaluminium chloride exhibited higher charge-neutralizing ability than alum and achieved lower turbidities than alum for equivalent Al dosages. Under the same operating conditions, the alum showed a higher grow rate, but with smaller floc size.

  12. What is the normal haemodynamic response to passive leg raise? A study of healthy volunteers.

    PubMed

    Elwan, Mohammed H; Roshdy, Ashraf; Reynolds, Joseph A; Elsharkawy, Eman M; Eltahan, Salah M; Coats, Timothy J

    2018-05-04

    Passive leg raise (PLR) is used as self-fluid challenge to optimise fluid therapy by predicting preload responsiveness. However, there remains uncertainty around the normal haemodynamic response to PLR with resulting difficulties in application and interpretation in emergency care. We aim to define the haemodynamic responses to PLR in spontaneously breathing volunteers using a non-invasive cardiac output monitor, thoracic electrical bioimpedance, TEB (PLR-TEB). We recruited healthy volunteers aged 18 or above. Subjects were monitored using TEB in a semirecumbent position, followed by PLR for 3 min. The procedure was repeated after 6 min at the starting position. Correlation between the two PLRs was assessed using Spearman's r (r s ). Agreement between the two PLRs was evaluated using Cohen Kappa with responsiveness defined as ≥10% increase in stroke volume. Parametric and non-parametric tests were used as appropriate to evaluate statistical significance of baseline variables between responders and non-responders. We enrolled 50 volunteers, all haemodynamically stable at baseline, of whom 49 completed the study procedure. About half of our subjects were preload responsive. The ∆SV in the two PLRs was correlated (r s =0.68, 95% CI 0.49 to 0.8) with 85% positive concordance. Good agreement was observed with Cohen Kappa of 0.67 (95% CI 0.45 to 0.88). Responders were older and had significantly lower baseline stroke volume and cardiac output. Our results suggest that the PLR-TEB is a feasible method in spontaneously breathing volunteers with reasonable reproducibility. The age and baseline stroke volume effect suggests a more complex underlying physiology than commonly appreciated. The fact that half of the volunteers had a positive preload response, against the 10% threshold, leads to questions about how this measurement should be used in emergency care and will help shape future patient studies. © Article author(s) (or their employer(s) unless otherwise

  13. Toward understanding the efficacy and mechanism of Opuntia spp. as a natural coagulant for potential application in water treatment.

    PubMed

    Miller, Sarah M; Fugate, Ezekiel J; Craver, Vinka Oyanedel; Smith, James A; Zimmerman, Julie B

    2008-06-15

    Historically, there is evidence to suggest that communities in the developing world have used plant-based materials as one strategy for purifying drinking water. In this study, the coagulant properties of Opuntia spp., a species of cactus, are quantitatively evaluated for the first time. Opuntia spp. was evaluated for turbidity removal from synthetic water samples, and steps were made toward elucidating the underlying coagulation mechanism. In model turbid water using kaolin clay particles at pH 10, Opuntia spp. reduced turbidity by 98% for a range of initial turbidities. This is similar to the observed coagulation activities previously described for Moringa oleifera, a widely studied natural coagulant. Although it has been reported that Moringa oleifera predominantly operates through charge neutralization, comparison of zeta potential measurements and transmission electron microscopy images of flocs formed by Opuntia spp. suggest that these natural coagulants operate through different mechanisms. It is suggested that Opuntia spp. operates predominantly through a bridging coagulation mechanism. Once optimized, application of these readily available plants as a part of point-of-use water treatment technology may offer a practical, inexpensive, and appropriate solution for producing potable water in some developing communities.

  14. Adherence and Coagulation Assays in Dabigatran-treated Patients With Atrial Fibrillation

    ClinicalTrials.gov

    2017-09-12

    Atrial Fibrillation; Medication Adherence; Blood Coagulation Tests; Anticoagulants; Circulating, Hemorrhagic Disorder; Drug Effect; Drug Use; Drug Toxicity; Drug Intolerance; Blood Clot; Blood Coagulation Disorder; Laboratory Problem; Bleeding; Thrombosis

  15. Haemodynamic effects of adrenaline (epinephrine) depend on chest compression quality during cardiopulmonary resuscitation in pigs.

    PubMed

    Pytte, Morten; Kramer-Johansen, Jo; Eilevstjønn, Joar; Eriksen, Morten; Strømme, Taevje A; Godang, Kristin; Wik, Lars; Steen, Petter Andreas; Sunde, Kjetil

    2006-12-01

    Adrenaline (epinephrine) is used during cardiopulmonary resuscitation (CPR) based on animal experiments without supportive clinical data. Clinically CPR was reported recently to have much poorer quality than expected from international guidelines and what is generally done in laboratory experiments. We have studied the haemodynamic effects of adrenaline during CPR with good laboratory quality and with quality simulating clinical findings and the feasibility of monitoring these effects through VF waveform analysis. After 4 min of cardiac arrest, followed by 4 min of basic life support, 14 pigs were randomised to ClinicalCPR (intermittent manual chest compressions, compression-to-ventilation ratio 15:2, compression depth 30-38 mm) or LabCPR (continuous mechanical chest compressions, 12 ventilations/min, compression depth 45 mm). Adrenaline 0.02 mg/kg was administered 30 s thereafter. Plasma adrenaline concentration peaked earlier with LabCPR than with ClinicalCPR, median (range), 90 (30, 150) versus 150 (90, 270) s (p = 0.007), respectively. Coronary perfusion pressure (CPP) and cortical cerebral blood flow (CCBF) increased and femoral blood flow (FBF) decreased after adrenaline during LabCPR (mean differences (95% CI) CPP 17 (6, 29) mmHg (p = 0.01), FBF -5.0 (-8.8, -1.2) ml min(-1) (p = 0.02) and median difference CCBF 12% of baseline (p = 0.04)). There were no significant effects during ClinicalCPR (mean differences (95% CI) CPP 4.7 (-3.2, 13) mmHg (p = 0.2), FBF -0.2 (-4.6, 4.2) ml min(-1)(p = 0.9) and CCBF 3.6 (-1.8, 9.0)% of baseline (p = 0.15)). Slope VF waveform analysis reflected changes in CPP. Adrenaline improved haemodynamics during laboratory quality CPR in pigs, but not with quality simulating clinically reported CPR performance.

  16. Effects of Rivaroxaban on Platelet Activation and Platelet–Coagulation Pathway Interaction

    PubMed Central

    Heitmeier, Stefan; Laux, Volker

    2015-01-01

    Introduction: Activation of coagulation and platelets is closely linked, and arterial thrombosis involves coagulation activation as well as platelet activation and aggregation. In these studies, we investigated the possible synergistic effects of rivaroxaban in combination with antiplatelet agents on thrombin generation and platelet aggregation in vitro and on arterial thrombosis and hemostasis in rat models. Materials and Methods: Thrombin generation was measured by the Calibrated Automated Thrombogram method (0.5 pmol/L tissue factor) using human platelet-rich plasma (PRP) spiked with rivaroxaban (15, 30, or 60 ng/mL), ticagrelor (1.0 µg/mL), and acetylsalicylic acid (ASA; 100 µg/mL). Tissue factor-induced platelet aggregation was measured in PRP spiked with rivaroxaban (15 or 30 ng/mL), ticagrelor (1 or 3 µg/mL), or a combination of these. An arteriovenous (AV) shunt model in rats was used to determine the effects of rivaroxaban (0.01, 0.03, or 0.1 mg/kg), clopidogrel (1 mg/kg), ASA (3 mg/kg), and combinations on arterial thrombosis. Results: Rivaroxaban inhibited thrombin generation in a concentration-dependent manner and the effect was enhanced with ticagrelor and ticagrelor plus ASA. Rivaroxaban and ticagrelor also concentration-dependently inhibited tissue factor-induced platelet aggregation, and their combination increased the inhibition synergistically. In the AV shunt model, rivaroxaban dose-dependently reduced thrombus formation. Combining subefficacious or weakly efficacious doses of rivaroxaban with ASA or ASA plus clopidogrel increased the antithrombotic effect. Conclusion: These data indicate that the combination of rivaroxaban with single or dual antiplatelet agents works synergistically to reduce platelet activation, which may in turn lead to the delayed/reduced formation of coagulation complexes and vice versa, thereby enhancing antithrombotic potency. PMID:25848131

  17. Comparison of haemodynamic responses following different concentrations of adrenaline with and without lignocaine for surgical field infiltration during cleft lip and cleft palate surgery in children.

    PubMed

    Muthukumar, Marimuthu; Arya, Virendra K; Mathew, Preety J; Sharma, Ramesh K

    2012-01-01

    Surgical field infiltration with adrenaline is common practice for quality surgical field during cleft lip and palate repair in children. Intravascular absorption of adrenaline infiltration often leads to adverse haemodynamic responses. In this prospective, double-blinded, randomised study the haemodynamic effects, quality of surgical field and postoperative analgesia following surgical field infiltration with different concentrations of adrenaline with and without lignocaine were compared in 100 American Society of Anesthesiologists physical status I children aged six months to seven years undergoing cleft lip/palate surgery. A standard anaesthesia protocol was used and they were randomised into four groups based on solution for infiltration: adrenaline 1:400,000 (group A), adrenaline 1:200,000 (group B), lignocaine + adrenaline 1:400,000 (group C) and lignocaine + adrenaline 1:200,000 (group D). Statistically significant tachycardia and hypertension occurred only in group B as compared to other groups (P <0.001). The peak changes in heart rate and mean arterial pressure following infiltration occurred at 4.3 ± 2.4, 3.8 ± 1.5, 5.7 ± 3.2 and 5.9 ± 4.9 minutes in groups A, B, C and D respectively. Surgical field was comparable among all groups. Postoperative pain scores and rescue analgesic requirements were lesser in the groups where lignocaine was added to the infiltrating solution (P <0.05). We found that 1:400000 or 1:200000 adrenaline with lignocaine 0.5 to 0.7% is most suitable for infiltration in terms of stable haemodynamics, quality of surgical field and good postoperative analgesia in children.

  18. Improvement of coagulation laboratory practice in Thailand: the first-year experience of the national external quality assessment scheme for blood coagulation.

    PubMed

    Tientadakul, Panutsaya; Opartkiattikul, Nisarat; Wongtiraporn, Wanida

    2009-01-01

    In Thailand until 2005 there had been no external quality assessment scheme at the national level for blood coagulation tests. Only a few laboratories had an external quality assessment for these tests. In the year 2005, the Thailand National External Quality Assessment Scheme for Blood Coagulation was founded. To describe the establishment of the Thailand National External Quality Assessment Scheme for Blood Coagulation (including problems encountered and solutions), its progression and expansion, and the improvement of coagulation laboratory practice in Thailand during 2 trial surveys and 4 formal surveys conducted in the first 1 1/2 years. Between 2005 and 2006, the external quality assessment samples for prothrombin time/international normalized ratio and activated partial thromboplastin time were distributed to the participants as well as the instructions and suggestions for the improvement of laboratory practice. From the data collected, the all-method coefficient of variation of the international normalized ratio and activated partial thromboplastin time was calculated for each survey. The number of participants increased during the first 1 1/2 years that the surveys were conducted, from 109 to 127. Survey data demonstrate an improvement in response rate and an increase in the number of laboratories that determine their own reference ranges and repeat this for every change of reagent lot, using the appropriate anticoagulant. The increased precision of tests is indicated by the decrease of the all-method coefficient of variation of the international normalized ratio and activated partial thromboplastin time. Examples of individual laboratory improvement through feedback are also described. The improvement of coagulation laboratory practice both through the instructions provided and liaison with participants was observed during the course of this scheme.

  19. Induced hypothermia does not impair coagulation system in a swine multiple trauma model.

    PubMed

    Mohr, Juliane; Ruchholtz, Steffen; Hildebrand, Frank; Flohé, Sascha; Frink, Michael; Witte, Ingo; Weuster, Matthias; Fröhlich, Matthias; van Griensven, Martijn; Keibl, Claudia; Mommsen, Philipp

    2013-04-01

    Accidental hypothermia, acidosis, and coagulopathy represent the lethal triad in severely injured patients. Therapeutic hypothermia however is commonly used in transplantations, cardiac and neurosurgical surgery, or after cardiac arrest. However, the effects of therapeutic hypothermia on the coagulation system following multiple trauma need to be elucidated. In a porcine model of multiple trauma including blunt chest injury, liver laceration, and hemorrhagic shock followed by fluid resuscitation, the influence of therapeutic hypothermia on coagulation was evaluated. A total of 40 pigs were randomly assigned to sham (only anesthesia) or trauma groups receiving either hypothermia or normothermia. Each group consisted of 10 pigs. Analyzed parameters were cell count (red blood cells, platelets), pH, prothrombin time (PT), fibrinogen concentration, and analysis with ROTEM and Multiplate. Trauma and consecutive fluid resuscitation resulted in impaired coagulation parameters (cell count, pH, PT, fibrinogen, ROTEM, and platelet function). During hypothermia, coagulation parameters measured at 37°C, such as PT, fibrinogen, thrombelastometry measurements, and platelet function, showed no significant differences between normothermic and hypothermic animals in both trauma groups. Additional analyses of thrombelastometry at 34°C during hypothermia showed significant differences for clotting time and clot formation time but not for maximum clot firmness. We were not able to detect macroscopic or petechial bleeding in both trauma groups. Based on the results of the present study we suggest that mild hypothermia can be safely performed after stabilization following major trauma. Mild hypothermia has effects on the coagulation system but does not aggravate trauma-induced coagulopathy in our model. Before hypothermic treatment can be performed in the clinical setting, additional experiments with prolonged and deeper hypothermia to exclude detrimental effects are required.

  20. Differences in coagulation among Asians and Caucasians and the implication for reconstructive microsurgery.

    PubMed

    Singhal, Dhruv; Smorodinsky, Emmanuil; Guo, Lifei

    2011-01-01

    Microvascular reconstructive surgery has seen a revival with the introduction of muscle-sparing perforator flaps. Recognition of potential ethnic differences in coagulation profiles would be important to a microvascular surgeon. Based on clinical observations, we hypothesize that Asian patients have a less thrombogenic coagulation profile than Caucasians. An extensive retrospective review was performed. The annual incidence of venous thromboembolism in the United States is generally accepted to range from 70 to 120 events per 100,000 people versus 16 to 17 events per 100,000 persons in Asia. Autopsy analysis of pulmonary embolism incidence was noted to be 15% in North Americans and less than 1% in Asian populations. Thromboelastography analysis of Asian and Caucasian patients undergoing cholecystectomy revealed different hemostatic mechanisms. Comparison of Asians and Caucasians undergoing the Fontan procedure revealed significantly lower postoperative factor levels in Asians than Caucasians. Baseline comparison of factor and serum levels revealed Asians with the least thrombogenic profiles compared with other ethnic groups. Asians and Caucasians demonstrate different baseline rates of deep vein thrombosis and pulmonary embolism, different hemostatic responses to surgery, and different baseline levels of clotting factors. Further study may lead to better pre-, intra-, and postoperative care of the free flap patient based on their ethnic coagulation profile. © Thieme Medical Publishers.

  1. [Point-of-care Coagulation Testing in Neurosurgery].

    PubMed

    Adam, Elisabeth Hannah; Füllenbach, Christoph; Lindau, Simone; Konczalla, Jürgen

    2018-06-01

    Disorders of the coagulation system can seriously impact the clinical course and outcome of neurosurgical patients. Due to the anatomical location of the central nervous system within the closed skull, bleeding complications can lead to devastating consequences such as an increase in intracranial pressure or enlargement of intracranial hematoma. Point-of-care (POC) devices for the testing of haemostatic parameters have been implemented in various fields of medicine. Major advantages of these devices are that results are available quickly and that analysis can be performed at the bedside, directly affecting patient management. POC devices allow identification of increased bleeding tendencies and therefore may enable an assessment of hemorrhagic risks in neurosurgical patients. Although data regarding the use of POC testing in neurosurgical patients are limited, they suggest that coagulation testing and hemostatic therapy using POC devices might have beneficial effects in this patient population. This article provides an overview of the application of point-of-care coagulation testing in clinical practice in neurosurgical patients. Georg Thieme Verlag KG Stuttgart · New York.

  2. Coagulation tests show significant differences in patients with breast cancer.

    PubMed

    Tas, Faruk; Kilic, Leyla; Duranyildiz, Derya

    2014-06-01

    Activated coagulation and fibrinolytic system in cancer patients is associated with tumor stroma formation and metastasis in different cancer types. The aim of this study is to explore the correlation of blood coagulation assays for various clinicopathologic factors in breast cancer patients. A total of 123 female breast cancer patients were enrolled into the study. All the patients were treatment naïve. Pretreatment blood coagulation tests including PT, APTT, PTA, INR, D-dimer, fibrinogen levels, and platelet counts were evaluated. Median age of diagnosis was 51 years old (range 26-82). Twenty-two percent of the group consisted of metastatic breast cancer patients. The plasma level of all coagulation tests revealed statistically significant difference between patient and control group except for PT (p<0.001 for all variables except for PT; p=0.08). Elderly age (>50 years) was associated with higher D-dimer levels (p=0.003). Metastatic patients exhibited significantly higher D-dimer values when compared with early breast cancer patients (p=0.049). Advanced tumor stage (T3 and T4) was associated with higher INR (p=0.05) and lower PTA (p=0.025). In conclusion, coagulation tests show significant differences in patients with breast cancer.

  3. Mercury, monomethyl mercury, and dissolved organic carbon concentrations in surface water entering and exiting constructed wetlands treated with metal-based coagulants, Twitchell Island, California

    USGS Publications Warehouse

    Stumpner, Elizabeth B.; Kraus, Tamara E.C.; Fleck, Jacob A.; Hansen, Angela M.; Bachand, Sandra M.; Horwath, William R.; DeWild, John F.; Krabbenhoft, David P.; Bachand, Philip A.M.

    2015-09-02

    Following coagulation, but prior to passage through the wetland cells, coagulation treatments transferred dissolved mercury and carbon to the particulate fraction relative to untreated source water: at the wetland cell inlets, the coagulation treatments decreased concentrations of filtered total mercury by 59–76 percent, filtered monomethyl mercury by 40–70 percent, and dissolved organic carbon by 65–86 percent. Passage through the wetland cells decreased the particulate fraction of mercury in wetland cells that received coagulant-treated water. Changes in total mercury, monomethyl mercury, and dissolved organic carbon concentrations resulting from wetland passage varied both by treatment and season. Despite increased monomethyl mercury in the filtered fraction during wetland passage between March and August, the coagulation-wetland systems generally decreased total mercury (filtered plus particulate) and monomethyl mercury (filtered plus particulate) concentrations relative to source water. Coagulation—either alone or in association with constructed wetlands—could be an effective way to decrease concentrations of mercury and dissolved organic carbon in surface water as well as the bioavailability of mercury in the Sacramento–San Joaquin Delta.

  4. Simultaneous assessment of blood coagulation and hematocrit levels in dielectric blood coagulometry.

    PubMed

    Hayashi, Yoshihito; Brun, Marc-Aurèle; Machida, Kenzo; Lee, Seungmin; Murata, Aya; Omori, Shinji; Uchiyama, Hidetoshi; Inoue, Yoshinori; Kudo, Toshifumi; Toyofuku, Takahiro; Nagasawa, Masayuki; Uchimura, Isao; Nakamura, Tomomasa; Muneta, Takeshi

    2017-01-01

    In a whole blood coagulation test, the concentration of any in vitro diagnostic agent in plasma is dependent on the hematocrit level but its impact on the test result is unknown. The aim of this work was to clarify the effects of reagent concentration, particularly Ca2+, and to find a method for hematocrit estimation compatible with the coagulation test. Whole blood coagulation tests by dielectric blood coagulometry (DBCM) and rotational thromboelastometry were performed with various concentrations of Ca2+ or on samples with different hematocrit levels. DBCM data from a previous clinical study of patients who underwent total knee arthroplasty were re-analyzed. Clear Ca2+ concentration and hematocrit level dependences of the characteristic times of blood coagulation were observed. Rouleau formation made hematocrit estimation difficult in DBCM, but use of permittivity at around 3 MHz made it possible. The re-analyzed clinical data showed a good correlation between permittivity at 3 MHz and hematocrit level (R2=0.83). Changes in the hematocrit level may affect whole blood coagulation tests. DBCM has the potential to overcome this effect with some automated correction using results from simultaneous evaluations of the hematocrit level and blood coagulability.

  5. [Coagulation factor VII levels in uremic patients and theirs influence factors].

    PubMed

    Fang, Jun; Xia, Ling-Hui; Wei, Wen-Ning; Song, Shan-Jun

    2004-12-01

    This study was aimed to investigate coagulation factor VII level in uremic patients with chronic renal failure and to explore theirs influence factors. The plasma levels of coagulation factor VII were detected in 30 uremic patients with chronic renal failure before and after hemodialysis for 1 month, the factor VII activity (FVII:C) was determined by one-stage coagulation method, while activated factor VII (FVIIa) was measured by one-stage coagulation method using recombinant soluble tissue factor, and factor VII antigen was detected by ELISA. The results showed that: (1) The FVIIa, FVII:C and FVIIAg levels in chronic uremic patients before hemodialysis were 4.00 +/- 0.86 microg/L, (148.5 +/- 40.4)% and (99.8 +/- 21.1)% respectively, which were significantly increased, as compared with healthy controls [2.77 +/- 1.02 microg/L, (113.1 +/- 33.0)% and (73.7 +/- 18.3)% respectively, P < 0.05]. (2) After hemodialysis the FVIIa, FVII:C and FVIIAg levels in uremic patients significantly enhanced to 5.56 +/- 1.45 microg/L, (200.8 +/- 68.7)% and (124.1 +/- 19.3)% respectively (P < 0.05). (3) The abnormal increase of coagulation factor VII was positively correlated with levels of blood uria nitrogen and serum creatinine before hemodialysis but not after hemodialysis. It is concluded that the enhanced levels of coagulation factor VII in chronic uremic patients suggested abnormal activated state, herperactivity and elevated production of factor VII which correlated with renal functional injury. The abnormality of factor VII in uremia may be aggravated by hemodialysis. Coagulation factor (FVII) may be a risk factor for cardiovascular events in uremic patients who especially had been accepted long-term hemodialysis.

  6. The Acid-Base Titration of a Very Weak Acid: Boric Acid

    ERIC Educational Resources Information Center

    Celeste, M.; Azevedo, C.; Cavaleiro, Ana M. V.

    2012-01-01

    A laboratory experiment based on the titration of boric acid with strong base in the presence of d-mannitol is described. Boric acid is a very weak acid and direct titration with NaOH is not possible. An auxiliary reagent that contributes to the release of protons in a known stoichiometry facilitates the acid-base titration. Students obtain the…

  7. Cost-Effectiveness of POC Coagulation Testing Using Multiple Electrode Aggregometry.

    PubMed

    Straub, Niels; Bauer, Ekaterina; Agarwal, Seema; Meybohm, Patrick; Zacharowski, Kai; Hanke, Alexander A; Weber, Christian F

    2016-01-01

    The economic effects of Point-of-Care (POC) coagulation testing including Multiple Electrode Aggregometry (MEA) with the Multiplate device have not been examined. A health economic model with associated clinical endpoints was developed to calculate the effectiveness and estimated costs of coagulation analyses based on standard laboratory testing (SLT) or POC testing offering the possibility to assess platelet dysfunction using aggregometric measures. Cost estimates included pre- and perioperative costs of hemotherapy, intra- and post-operative coagulation testing costs, and hospitalization costs, including the costs of transfusion-related complications. Our model calculation using a simulated true-to-life cohort of 10,000 cardiac surgery patients assigned to each testing alternative demonstrated that there were 950 fewer patients in the POC branch who required any transfusion of red blood cells. The subsequent numbers of massive transfusions and patients with transfusion-related complications were reduced with the POC testing by 284 and 126, respectively. The average expected total cost in the POC branch was 288 Euro lower for every treated patient than that in the SLT branch. Incorporating aggregometric analyses using MEA into hemotherapy algorithms improved medical outcomes in cardiac surgery patients in the presented health economic model. There was an overall better economic outcome associated with POC testing compared with SLT testing despite the higher costs of testing.

  8. Coagulation under flow: the influence of flow-mediated transport on the initiation and inhibition of coagulation.

    PubMed

    Fogelson, Aaron L; Tania, Nessy

    2005-01-01

    A mathematical model of intravascular coagulation is presented; it encompasses the biochemistry of the tissue factor pathway, platelet activation and deposition on the subendothelium, and flow- and diffusion-mediated transport of coagulation proteins and platelets. Simulation experiments carried out with the model indicate the predominant role played by the physical processes of platelet deposition and flow-mediated removal of enzymes in inhibiting coagulation in the vicinity of vascular injury. Sufficiently rapid production of factors IXa and Xa by the TF:VIIa complex can overcome this inhibition and lead to formation of significant amounts of the tenase complex on the surface of activated platelets and, as a consequence, to substantial thrombin production. Chemical inhibitors are seen to play almost no (TFPI) or little (AT-III and APC) role in determining whether substantial thrombin production will occur. The role of APC is limited by the necessity for diffusion of thrombin from the site of injury to nearby endothelial cells to form the thrombomodulin-thrombin complex and for diffusion in the reverse direction of the APC made by this complex. TFPI plays an insignificant part in inhibiting the TF:VIIa complex under the conditions studied whether its action involves sequential binding of TFPI to Xa and then TFPI:Xa to TF:VIIa, or direct binding of TFPI to Xa already bound to the TF:VIIa complex. Copyright 2005 S. Karger AG, Basel.

  9. Reduction of Turbidity of Water Using Locally Available Natural Coagulants

    PubMed Central

    Asrafuzzaman, Md.; Fakhruddin, A. N. M.; Hossain, Md. Alamgir

    2011-01-01

    Turbidity imparts a great problem in water treatment. Moringa oleifera, Cicer arietinum, and Dolichos lablab were used as locally available natural coagulants in this study to reduce turbidity of synthetic water. The tests were carried out, using artificial turbid water with conventional jar test apparatus. Optimum mixing intensity and duration were determined. After dosing water-soluble extracts of Moringa oleifera, Cicer arietinum, and Dolichos lablab reduced turbidity to 5.9, 3.9, and 11.1 nephelometric turbidity unit (NTU), respectively, from 100 NTU and 5, 3.3, and 9.5, NTU, respectively, after dosing and filtration. Natural coagulants worked better with high, turbid, water compare to medium, or low, turbid, water. Highest turbidity reduction efficiency (95.89%) was found with Cicer arietinum. About 89 to 96% total coliform reduction were also found with natural coagulant treatment of turbid water. Using locally available natural coagulants, suitable, easier, and environment friendly options for water treatment were observed. PMID:23724307

  10. Multiple roles of the coagulation protease cascade during virus infection.

    PubMed

    Antoniak, Silvio; Mackman, Nigel

    2014-04-24

    The coagulation cascade is activated during viral infections. This response may be part of the host defense system to limit spread of the pathogen. However, excessive activation of the coagulation cascade can be deleterious. In fact, inhibition of the tissue factor/factor VIIa complex reduced mortality in a monkey model of Ebola hemorrhagic fever. Other studies showed that incorporation of tissue factor into the envelope of herpes simplex virus increases infection of endothelial cells and mice. Furthermore, binding of factor X to adenovirus serotype 5 enhances infection of hepatocytes but also increases the activation of the innate immune response to the virus. Coagulation proteases activate protease-activated receptors (PARs). Interestingly, we and others found that PAR1 and PAR2 modulate the immune response to viral infection. For instance, PAR1 positively regulates TLR3-dependent expression of the antiviral protein interferon β, whereas PAR2 negatively regulates expression during coxsackievirus group B infection. These studies indicate that the coagulation cascade plays multiple roles during viral infections.

  11. RBC Storage Effect on Coagulation, Microparticles and Microchimerism in Critically Ill Patients

    DTIC Science & Technology

    2015-03-01

    Award Number: W81XWH-11-2-0028 TITLE: “RBC Storage Effect on Coagulation, Microparticles and Microchimerism in Critically Ill Patients...27 DEC 2010 - 26 DEC 2015 – 4. TITLE AND SUBTITLE "“RBC Storage Effect on Coagulation, Microparticles and 5a. CONTRACT NUMBER Microchimerism in...15. SUBJECT TERMS RBC storage age; microchimerism; critically ill patients; coagulation; microparticles 16. SECURITY CLASSIFICATION OF: U 17

  12. Effect of intravenous infusion of dexmedetomidine on perioperative haemodynamic changes and postoperative recovery: A study with entropy analysis.

    PubMed

    Patel, Chirag Ramanlal; Engineer, Smita R; Shah, Bharat J; Madhu, S

    2012-11-01

    Dexmedetomidine, an α2 agonist, when used as an adjuvant in general anaesthesia attenuates stress response to various noxious stimuli, maintains perioperative haemodynamic stability and provides sedation without significant respiratory depression postoperatively. Sixty patients were randomly divided into two groups of 30 each. In group A, fentanyl 2 μg/kg and in group B dexmedetomidine were given intravenously as loading dose of 1 μg/kg over 10 min prior to induction. After induction with thiopentone, in group B, dexmedetomidine was given as infusion at a dose of 0.2-0.8 μg/kg. Sevoflurane was used as inhalation agent in both groups. Haemodynamic variables and entropy (response entropy and state entropy) were recorded continuously. Postoperative sedation and recovery were assessed by sedation score and modified Aldrete's score, respectively. Dexmedetomidine significantly attenuates stress response at intubation with lesser increase in heart rate (10% vs. 17%), systolic blood pressure (6% vs. 23%) and diastolic blood pressure (7% vs. 20%) as compared to the control group (P<0.05). Intraoperatively, an average of 8% fall in systolic blood pressure and 8.16% fall in diastolic pressure in the test group as compared to 3.6% rise in systolic and 3.3% in diastolic pressure of the control group was observed. Postoperatively, the test group showed significant sedation at 2 h as compared to the control group (P=0.00) and recovery was better in the control group for the first 2 h post extubation. Dexmedetomidine attenuates various stress responses during surgery and maintains the haemodynamic stability when used as an adjuvant in general anaesthesia. Also, the sedative action of dexmedetomidine delays recovery for the first few hours post extubation.

  13. Effectiveness and mechanism of potassium ferrate(VI) preoxidation for algae removal by coagulation.

    PubMed

    Ma, Jun; Liu, Wei

    2002-02-01

    Jar tests were conducted to evaluate the effectiveness of potassium ferrate preoxidation on algae removal by coagulation. Laboratory studies demonstrated that pretreatment with potassium ferrate obviously enhanced the algae removal by coagulation with alum [Al2(SO4)3 . 18H2O]. Algae removal efficiency increased remarkably when the water was pretreated with ferrate. A very short time of preoxidation was enough to achieve substantial algae removal efficiency, and the effectiveness was further increased at a prolonged pretreatment time. Pretreatment with ferrate resulted in a reduction of alum dosage required to cause an efficient coagulation for algae removal. The obvious impact of cell architecture by potassium ferrate was found through scanning electron microscopy. Upon oxidation with ferrate. the cells were inactivated and some intracellular and extracelluar components were released into the water, which may be helpful to the coagulation by their bridging effect. Efficient removal of algae by potassium ferrate preoxidation is believed to be a consequence of several process mechanisms. Ferrate preoxidation inactivated algae, induced the formation of coagulant aid, which are the cellular components secreted by algal cells. The coagulation was also improved by increasing particle concentration in water, because of the formation of the intermediate forms of precipitant iron species during preoxidation. In addition, it was also observed that ferrate preoxidation caused algae agglomerate formation before the addition of coagulant, the subsequent application of alum resulted in further coagulation.

  14. The haemodynamic effects of bolus versus slower infusion of intravenous crystalloid in healthy volunteers.

    PubMed

    Ukor, Ida F; Hilton, Andrew K; Bailey, Michael J; Bellomo, Rinaldo

    2017-10-01

    This pilot study aimed to characterise the haemodynamic effect of 1L of IV normal saline (NS) administered as a rapid versus slow infusion on cardiac output (CO), heart rate (HR), systemic blood pressures, and carotid blood flow in six healthy volunteers. Six healthy male volunteers aged 18-65years were randomized to receive 1L NS given over 30min or 120min. On a subsequent study session the alternate fluid regimen was administered. Haemodynamic data was gathered using a non-invasive finger arterial pressure monitor (Nexfin®), echocardiography and carotid duplex sonography. Time to micturition and urine volume was also assessed. Compared to baseline, rapid infusion of 1L of saline over 30min produced a fall in Nexfin®-measured CO by 0.62L/min (p<0.001), whereas there was a marginal but significant increase during infusion of 1L NS over 120min of 0.02L/min (p<0.001). This effect was mirrored by changes in HR and blood pressure (BP) (p<0.001). There were no significant changes in carotid blood flow, time to micturition, or urine volume produced. Slower infusion of 1L NS in healthy male volunteers produced a greater increase in CO, HR and BP than rapid infusion. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  15. Wide-field optical mapping of neural activity and brain haemodynamics: considerations and novel approaches

    PubMed Central

    Ma, Ying; Shaik, Mohammed A.; Kozberg, Mariel G.; Thibodeaux, David N.; Zhao, Hanzhi T.; Yu, Hang

    2016-01-01

    Although modern techniques such as two-photon microscopy can now provide cellular-level three-dimensional imaging of the intact living brain, the speed and fields of view of these techniques remain limited. Conversely, two-dimensional wide-field optical mapping (WFOM), a simpler technique that uses a camera to observe large areas of the exposed cortex under visible light, can detect changes in both neural activity and haemodynamics at very high speeds. Although WFOM may not provide single-neuron or capillary-level resolution, it is an attractive and accessible approach to imaging large areas of the brain in awake, behaving mammals at speeds fast enough to observe widespread neural firing events, as well as their dynamic coupling to haemodynamics. Although such wide-field optical imaging techniques have a long history, the advent of genetically encoded fluorophores that can report neural activity with high sensitivity, as well as modern technologies such as light emitting diodes and sensitive and high-speed digital cameras have driven renewed interest in WFOM. To facilitate the wider adoption and standardization of WFOM approaches for neuroscience and neurovascular coupling research, we provide here an overview of the basic principles of WFOM, considerations for implementation of wide-field fluorescence imaging of neural activity, spectroscopic analysis and interpretation of results. This article is part of the themed issue ‘Interpreting BOLD: a dialogue between cognitive and cellular neuroscience’. PMID:27574312

  16. Characterization of micro-flocs of NOM coagulated by PACl, alum and polysilicate-iron in terms of molecular weight and floc size.

    PubMed

    Fusheng, Li; Akira, Yuasa; Yuka, Ando

    2008-01-01

    Micro-flocs of NOM coagulated by polyaluminium chloride (PACl), alum and polysilicate-iron (PSI) were characterized by flocs size, HPSEC-based molecular weight and the captured content of coagulants-based aluminium and iron. Changes in floc composition with respect to the mass ratios of captured NOM to Al and Fe were examined. Lowering water pH to optimum levels was found to be capable of removing small NOM constituents that are generally difficult to be precipitated at neutral pH levels. For PACl and PSI, the distribution of micro flocs (0.1-5.0 microm) reached steady stage after rapid mixing for 30 seconds, with NOM being found existent within the non-coagulated fraction (d<0.1 microm) and the coagulated fraction with floc sizes above 5.0 microm (d >5.0 microm). For alum, however, the existence of NOM inside intermediate floc fractions of d = 0.1-1.0 microm, 1.0-3.0microm and 3.0-5.0 microm was confirmed.

  17. Coagulation pretreatment for ultrafiltration of deinking effluents containing flexographic inks

    Treesearch

    Bruno Chabot; Gopal A. Krishnagopalan; Said Abubakr

    1999-01-01

    This study was carried out to determine the potential of coagulation pretreatment with organic or inorganic coagulants to improve ultrafiltration performance during processing of wash deinking effluents containing flexographic inks. Wash filtrate effluents generated from mixtures of old flexographic and offset newspapers and old magazines were pretreated with a...

  18. Blood coagulation using High Intensity Focused Ultrasound (HIFU)

    NASA Astrophysics Data System (ADS)

    Nguyen, Phuc V.; Oh, Junghwan; Kang, Hyun Wook

    2014-03-01

    High Intensity Focused Ultrasound (HIFU) technology provides a feasible method of achieving thermal coagulation during surgical procedures. One of the potential clinical benefits of HIFU can induce immediate hemostasis without suturing. The objective of this study was to investigate the efficiency of a HIFU system for blood coagulation on severe vascular injury. ngHIFU treatment was implemented immediately after bleeding in artery. The ultrasound probe was made of piezoelectric material, generating a central frequency of 2.0 MHz as well as an ellipsoidal focal spot of 2 mm in lateral dimension and 10 mm in axial dimension. Acoustic coagulation was employed on a perfused chicken artery model in vitro. A surgical incision (1 to 2 mm long) was made with a scapel on the arterial wall, and heparinized autologous blood was made to leak out from the incision with a syringe pump. A total of 5 femoral artery incisions was treated with the HIFU beam. The intensity of 4500 W/cm2 at the focus was applied for all treatments. Complete hemostasis was achieved in all treatments, along with the treatment times of 25 to 50 seconds. The estimated intraoperative blood loss was from 2 to 5 mL. The proposed HIFU system may provide an effective method for immediate blood coagulation for arteries and veins in clinical applications.

  19. Cosmetic wastewater treatment by coagulation and advanced oxidation processes.

    PubMed

    Naumczyk, Jeremi; Bogacki, Jan; Marcinowski, Piotr; Kowalik, Paweł

    2014-01-01

    In this study, the treatment process of three cosmetic wastewater types has been investigated. Coagulation allowed to achieve chemical oxygen demand (COD) removal of 74.6%, 37.7% and 74.0% for samples A (Al2(SO4)3), B (Brentafloc F3) and C (PAX 16), respectively. The Fenton process proved to be effective as well - COD removal was equal to 75.1%, 44.7% and 68.1%, respectively. Coagulation with FeCl3 and the subsequent photo-Fenton process resulted in the best values of final COD removal equal to 92.4%, 62.8% and 90.2%. In case of the Fenton process, after coagulation these values were equal to 74.9%, 50.1% and 84.8%, while in case of the H2O2/UV process, the obtained COD removal was 83.8%, 36.2% and 80.9%. High value of COD removal in the Fenton process carried out for A and C wastewater samples was caused by a significant contribution of the final neutralization/coagulation. Very small effect of the oxidation reaction in the Fenton process in case of sample A resulting from the presence of antioxidants, 'OH radical scavengers' in the wastewater.

  20. Innovative physico-chemical treatment of wastewater incorporating Moringa oleifera seed coagulant.

    PubMed

    Bhuptawat, Hitendra; Folkard, G K; Chaudhari, Sanjeev

    2007-04-02

    Moringa oleifera is a pan tropical, multipurpose tree whose seeds contain a high quality edible oil (up to 40% by weight) and water soluble proteins that act as effective coagulants for water and wastewater treatment. The use of this natural coagulant material has not yet realised its potential. A water extract of M. oleifera seed was applied to a wastewater treatment sequence comprising coagulation-flocculation-sedimentation-sand filtration. The study was laboratory based using an actual wastewater. Overall COD removals of 50% were achieved at both 50 and 100mg/l M. oleifera doses. When 50 and 100mg/l seed doses were applied in combination with 10mg/l of alum, COD removal increased to 58 and 64%, respectively. The majority of COD removal occurred during the filtration process. In the tests incorporating alum, sludge generation and filter head loss increased by factors of 3 and 2, respectively. These encouraging treatment results indicate that this may be the first treatment application that can move to large scale adoption. The simple water extract may be obtained at minimal cost from the presscake residue remaining after oil extraction from the seed. The regulatory compliance issues of adopting 'new materials' for wastewater treatment are significantly less stringent than those applying to the production of potable water.

  1. Mature landfill leachate treatment by coagulation/flocculation combined with Fenton and solar photo-Fenton processes.

    PubMed

    Amor, Carlos; De Torres-Socías, Estefanía; Peres, José A; Maldonado, Manuel I; Oller, Isabel; Malato, Sixto; Lucas, Marco S

    2015-04-09

    This work reports the treatment of a mature landfill leachate through the application of chemical-based treatment processes in order to achieve the discharge legal limits into natural water courses. Firstly, the effect of coagulation/flocculation with different chemicals was studied, evaluating the role of different initial pH and chemicals concentration. Afterwards, the efficiency of two different advanced oxidation processes for leachate remediation was assessed. Fenton and solar photo-Fenton processes were applied alone and in combination with a coagulation/flocculation pre-treatment. This physicochemical conditioning step, with 2 g L(-1) of FeCl3 · 6H2O at pH 5, allowed removing 63% of COD, 80% of turbidity and 74% of total polyphenols. Combining the coagulation/flocculation pre-treatment with Fenton reagent, it was possible to reach 89% of COD removal in 96 h. Moreover, coagulation/flocculation combined with solar photo-Fenton revealed higher DOC (75%) reductions than single solar photo-Fenton (54%). In the combined treatment (coagulation/flocculation and solar photo-Fenton), it was reached a DOC reduction of 50% after the chemical oxidation, with 110 kJ L(-1) of accumulated UV energy and a H2O2 consumption of 116 mM. Toxicity and biodegradability assays were performed to evaluate possible variations along the oxidation processes. After the combined treatment, the leachate under study presented non-toxicity but biodegradability increased. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Removal of natural organic matter in drinking water treatment by coagulation: A comprehensive review.

    PubMed

    Sillanpää, Mika; Ncibi, Mohamed Chaker; Matilainen, Anu; Vepsäläinen, Mikko

    2018-01-01

    Natural organic matter (NOM) is a complex matrix of organic substances produced in (or channeled to) aquatic ecosystems via various biological, geological and hydrological cycles. Such variability is posing a serious challenge to most water treatment technologies, especially the ones designed to treat drinking water supplies. Lately, in addition to the fluctuating composition of NOM, a substantial increase of its concentration in fresh waters, and also municipal wastewater effluents, has been reported worldwide, which justifies the urgent need to develop highly efficient and versatile water treatment processes. Coagulation is among the most applied processes for water and wastewater treatment. The application of coagulation to remove NOM from drinking water supplies has received a great deal of attention from researchers around the world because it was efficient and helped avoiding the formation of disinfection by products (DBPs). Nonetheless, with the increased fluctuation of NOM in water (concentration and composition), the efficiency of conventional coagulation was substantially reduced, hence the need to develop enhanced coagulation processes by optimizing the operating conditions (mainly the amount coagulants and pH), developing more efficient inorganic or organic coagulants, as well as coupling coagulation with other water treatment technologies. In the present review, recent research studies dealing with the application of coagulation for NOM removal from drinking water supplies are presented and compared. In addition, integration schemes combining coagulation and other water treatment processes are presented, including membrane filtration, oxidation, adsorption and others processes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Establishment of reference values for various coagulation tests in healthy Florida manatees (Trichechus manatus latirostris) and evaluation of coagulation in debilitated manatees during rehabilitation.

    PubMed

    Gerlach, Trevor J; Bandt, Carsten; Conner, Bobbi; Ball, Ray L

    2015-11-01

    To establish reference ranges for coagulation parameters in healthy Florida manatees (Trichechus manatus latirostris) and compare results with those for debilitated manatees undergoing treatment at a rehabilitation facility. Prospective study. 29 healthy manatees and 45 debilitated manatees with various diseases. Manatees considered healthy on the basis of results of physical examination, CBC, and serum biochemical analysis underwent coagulation testing including measurement of prothrombin time, partial thromboplastin time, D-dimer concentration, platelet count, and fibrinogen concentration to establish reference ranges. For comparison, a group of manatees undergoing rehabilitation was also tested, and the results were compared. Thromboelastography was also performed on some animals. Values for D-dimer concentration were significantly higher in debilitated versus healthy animals. There was no significant difference for prothrombin time, partial thromboplastin time, platelet count, or fibrinogen concentration between groups. Thromboelastography was performed on 8 healthy animals. Reference ranges were established for various tests of coagulation that may assist clinicians during the initial evaluation and rehabilitation of Florida manatees. Future research to evaluate the effect of specific disease processes on the coagulation cascade is recommended.

  4. Natural organic matters removal efficiency by coagulation

    NASA Astrophysics Data System (ADS)

    Sapingi, Mohd Sharizal Mohd; Pishal, Munirah; Murshed, Mohamad Fared

    2017-10-01

    The presence of Natural Organic Matter (NOM) in surface water results in unwanted characteristics in terms of color, odor, and taste. NOM content reaction with free chlorine in treated water lowers the water quality further. Chlorine is added for disinfection and produces undesirable disinfection by-products (DPBs). DBPs in drinking water are carcinogenic to consumers and may promote cancerous cell development in the human body. This study was performed to compare the coagulant efficiency of aluminum sulfate (Alum) and ferric chloride (FeCl3) on NOM removal (as in UV254 absorbance) and turbidity removal under three pH conditions (pH 6, pH 7, and sample actual pH). The three sampling points for these studies were Jalan Baru River, Kerian River, and Redac Pond. Additional sampling points, such as Lubuk Buntar and a tubewell located in the Civil Engineering School, were included to observe differences in characteristics. DOC, UV absorbance, and full wavelength were tested, after which samples treated with alum were also tested to further analyze the NOM content. Based on UV254 absorbance and DOC data, specific UV value was calculated to obtain vital synopsis of the characteristics of NOM content, as well as coagulation efficiency.

  5. Effect of AlCl3 concentration on nanoparticle removal by coagulation.

    PubMed

    Zhang, Lizhu; Mao, Jingchun; Zhao, Qing; He, Shaobo; Ma, Jun

    2015-12-01

    In recent years, engineered nanoparticles, as a new group of contaminants emerging in natural water, have been given more attention. In order to understand the behavior of nanoparticles in the conventional water treatment process, three kinds of nanoparticle suspensions, namely multi-walled carbon nanotube-humic acid (MWCNT-HA), multi-walled carbon nanotube-N,N-dimethylformamide (MWCNT-DMF) and nanoTiO2-humic acid (TiO2-HA) were employed to investigate their coagulation removal efficiencies with varying aluminum chloride (AlCl3) concentrations. Results showed that nanoparticle removal rate curves had a reverse "U" shape with increasing concentration of aluminum ion (Al(3+)). More than 90% of nanoparticles could be effectively removed by an appropriate Al(3+) concentration. At higher Al(3+) concentration, nanoparticles would be restabilized. The hydrodynamic particle size of nanoparticles was found to be the crucial factor influencing the effective concentration range (ECR) of Al(3+) for nanoparticle removal. The ECR of Al(3+) followed the order MWCNT-DMF>MWCNT-HA>TiO2-HA, which is the reverse of the nanoparticle size trend. At a given concentration, smaller nanoparticles carry more surface charges, and thus consume more coagulants for neutralization. Therefore, over-saturation occurred at relatively higher Al(3+) concentration and a wider ECR was obtained. The ECR became broader with increasing pH because of the smaller hydrodynamic particle size of nanoparticles at higher pH values. A high ionic strength of NaCl can also widen the ECR due to its strong potential to compress the electric double layer. It was concluded that it is important to adjust the dose of Al(3+) in the ECR for nanoparticle removal in water treatment. Copyright © 2015. Published by Elsevier B.V.

  6. Reduction of disinfection by-product precursors in reservoir water by coagulation and ultrafiltration.

    PubMed

    Wang, Feng; Gao, Baoyu; Ma, Defang; Yue, Qinyan; Li, Ruihua; Wang, Qianwen

    2016-11-01

    In this study, reservoir water intended for drinking water supply was treated by (i) ultrafiltration (UF) (ii) coagulation (CW) (iii) coagulation combined with ultrafiltration (CW-UF). To probe the influences of three treatment processes on disinfection byproduct (DBP) precursors in source water, the changes of dissolved organic matter (DOM) amounts and physicochemical properties, and disinfection byproduct (DBP) formation characteristics during chlorine disinfection were investigated. Both carbonaceous DBP (C-DBP) and nitrogenous DBP (N-DBP) formation and speciation were analyzed. The influence of chlorine dose, contact time on DBP formation and speciation were also studied to optimize the disinfection conditions to minimize the DBP formation. Compared with UF and CW alone, CW-UF improved the dissolved organic carbon (DOC) removal from about 20 % to 59 %. The three-dimensional excitation and emission matrix (3DEEM) fluorescence spectroscopy analysis showed that CW-UF had high removal efficiency in microbial products (Region IV), fulvic acid-like (Region III) and humic acid-like (Region V). The total C-DBP was determined by the formation of trihalomethanes and trichloromethane was the most abundant species (40 %). The most abundant N-DBP species was dichloroacetonitrile (32.5 %), followed by trichloroactetonitrile. CW-UF effectively reduced the risk of DBPs in drinking water supply by reducing 30.8 % and 16.9 % DBPs formation potential compared with UF and CW alone. Increasing contact time improved the yields of both C-DBPs and N-DBPs. Chlorine dosage had slight influence on DBP yield in this study.

  7. Removal of refractory organics in nanofiltration concentrates of municipal solid waste leachate treatment plants by combined Fenton oxidative-coagulation with photo--Fenton processes.

    PubMed

    Li, Jiuyi; Zhao, Lei; Qin, Lele; Tian, Xiujun; Wang, Aimin; Zhou, Yanmei; Meng, Liao; Chen, Yong

    2016-03-01

    Removal of the refractory organic matters in leachate brines generated from nanofiltration unit in two full-scale municipal solid waste landfill leachate treatment plants was investigated by Fenton oxidative-coagulation and ultraviolet photo - Fenton processes in this study. Fenton oxidative-coagulation was performed under the condition of an initial pH of 5.0 and low H2O2/Fe(2+) ratios. After precipitate separation, the remaining organic constituents were further oxidized by photo - Fenton process. For both leachate brines with varying pollution strength, more than 90% COD and TOC reductions were achieved at H2O2/Fe(2+) dosages of 35 mM/8 mM and 90 mM/10 mM, respectively. The effluent COD ranged 120-160 mg/L under the optimal operating conditions, and the biodegradability was increased significantly. Fenton oxidative-coagulation was demonstrated to contribute nearly 70% overall removal of organic matters. In the combined processes, the efficiency of hydrogen peroxide varied from 216 to 228%, which may significantly reduce the operating cost of conventional Fenton method. Six phthalic acid esters and thirteen polycyclic aromatic hydrocarbons were found in leachate brines, and, on the average, around 80% phthalic acid esters and 90% polycyclic aromatic hydrocarbons were removed by the combined treatments. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Removal of total suspended solid by natural coagulant derived from cassava peel waste

    NASA Astrophysics Data System (ADS)

    Mohd-Asharuddin, S.; Othman, N.; Mohd-Zin, N. S.; Tajarudin, H. A.

    2018-04-01

    The present study was aimed to investigate the performance of starch derived from cassava peel waste as primary coagulant and coagulant aid. Comparable study was also conducted using commercially used aluminium sulfate (alum) as primary coagulant. A series of Jar tests were performed using raw water from Sembrong Barat water treatment plant. It was observed that coagulation test using cassava peel starch (CPS) alone had unappreciable removing ability. However, it was found that combination of alum-CPS successfully achieve up to 90.48% of total suspended solid (TSS) removal under optimized working conditions (pH 9, 7.5mg/L : 100 mg/L of alum : CPS dosage, rapid mixing of 200 rpm for 1 minute; 100 rpm for 2 minutes, slow mixing of 25 rpm for 30 minutes and 30 minutes settling time). This remarks the reduction in alum dosage up to 50% compared to coagulation test using alum alone. Therefore this finding suggesting that CPS can be considered as potential source of sustainable and effective coagulant aid for water treatment especially in developing countries.

  9. Coagulation challenges after severe injury with hemorrhagic shock.

    PubMed

    Ledgerwood, Anna M; Blaisdell, William

    2012-06-01

    hemostatic regimen which consists of platelets, RBC, and FFP in a 1:1:1 ratio. This recommendation is still being assessed with different authors reporting benefits and detriments. Throughout these years, an unusual entity of disseminated intravascular coagulation (DIC) was known to complicate the resuscitation of seriously injured patients with HS. This syndrome was typically seen after treatment of HS and was associated with abnormal bleeding plus respiratory failure and renal failure thought to be caused by a combination of micro- and macrothromboses. The early studies suggested that the best therapy for breaking this viscous cycle of bleeding and intravascular coagulation was by infusing fresh whole blood. The theoretical benefits of administering heparin to prevent the thrombosis and epsilon-aminocaproic acid to enhance lysis have not proven beneficial. DIC is also seen in association with toxic exposures, including snake bites. Epsilon-aminocaproic acid may be beneficial in that setting. Many of the intricate understandings of DIC remain elusive and are still being studied. Copyright © 2012 by Lippincott Williams & Wilkins.

  10. Causes and consequences of coagulation activation in sepsis: an evolutionary medicine perspective.

    PubMed

    Fiusa, Maiara Marx Luz; Carvalho-Filho, Marco Antonio; Annichino-Bizzacchi, Joyce M; De Paula, Erich V

    2015-05-06

    Coagulation and innate immunity have been linked together for at least 450 million years of evolution. Sepsis, one of the world's leading causes of death, is probably the condition in which this evolutionary link is more evident. However, the biological and the clinical relevance of this association have only recently gained the attention of the scientific community. During sepsis, the host response to a pathogen is invariably associated with coagulation activation. For several years, coagulation activation has been solely regarded as a mechanism of tissue damage, a concept that led to several clinical trials of anticoagulant agents for sepsis. More recently, this paradigm has been challenged by the failure of these clinical trials, and by a growing bulk of evidence supporting the concept that coagulation activation is beneficial for pathogen clearance. In this article we discuss recent basic and clinical data that point to a more balanced view of the detrimental and beneficial consequences of coagulation activation in sepsis. Reappraisal of the association between coagulation and immune activation from an evolutionary medicine perspective offers a unique opportunity to gain new insights about the pathogenesis of sepsis, paving the way to more successful approaches in both basic and clinical research in this field.

  11. Multipurpose HTS Coagulation Analysis: Assay Development and Assessment of Coagulopathic Snake Venoms

    PubMed Central

    Still, Kristina B. M.; Nandlal, Randjana S. S.; Slagboom, Julien; Somsen, Govert W.; Kool, Jeroen

    2017-01-01

    Coagulation assays currently employed are often low throughput, require specialized equipment and/or require large blood/plasma samples. This study describes the development, optimization and early application of a generic low-volume and high-throughput screening (HTS) assay for coagulation activity. The assay is a time-course spectrophotometric measurement which kinetically measures the clotting profile of bovine or human plasma incubated with Ca2+ and a test compound. The HTS assay can be a valuable new tool for coagulation diagnostics in hospitals, for research in coagulation disorders, for drug discovery and for venom research. A major effect following envenomation by many venomous snakes is perturbation of blood coagulation caused by haemotoxic compounds present in the venom. These compounds, such as anticoagulants, are potential leads in drug discovery for cardiovascular diseases. The assay was implemented in an integrated analytical approach consisting of reversed-phase liquid chromatography (LC) for separation of crude venom components in combination with parallel post-column coagulation screening and mass spectrometry (MS). The approach was applied for the rapid assessment and identification of profiles of haemotoxic compounds in snake venoms. Procoagulant and anticoagulant activities were correlated with accurate masses from the parallel MS measurements, facilitating the detection of peptides showing strong anticoagulant activity. PMID:29186818

  12. Simultaneous assessment of blood coagulation and hematocrit levels in dielectric blood coagulometry

    PubMed Central

    Hayashi, Yoshihito; Brun, Marc-Aurèle; Machida, Kenzo; Lee, Seungmin; Murata, Aya; Omori, Shinji; Uchiyama, Hidetoshi; Inoue, Yoshinori; Kudo, Toshifumi; Toyofuku, Takahiro; Nagasawa, Masayuki; Uchimura, Isao; Nakamura, Tomomasa; Muneta, Takeshi

    2017-01-01

    Background: In a whole blood coagulation test, the concentration of any in vitro diagnostic agent in plasma is dependent on the hematocrit level but its impact on the test result is unknown. Objective: The aim of this work was to clarify the effects of reagent concentration, particularly Ca2+, and to find a method for hematocrit estimation compatible with the coagulation test. Methods: Whole blood coagulation tests by dielectric blood coagulometry (DBCM) and rotational thromboelastometry were performed with various concentrations of Ca2+ or on samples with different hematocrit levels. DBCM data from a previous clinical study of patients who underwent total knee arthroplasty were re-analyzed. Results: Clear Ca2+ concentration and hematocrit level dependences of the characteristic times of blood coagulation were observed. Rouleau formation made hematocrit estimation difficult in DBCM, but use of permittivity at around 3 MHz made it possible. The re-analyzed clinical data showed a good correlation between permittivity at 3 MHz and hematocrit level (R2=0.83). Conclusions: Changes in the hematocrit level may affect whole blood coagulation tests. DBCM has the potential to overcome this effect with some automated correction using results from simultaneous evaluations of the hematocrit level and blood coagulability. PMID:28800301

  13. Effects of systolic anterior motion of the mitral valve on haemodynamics. Evaluation by a direct method.

    PubMed

    Kaku, T; Sakurai, S; Furuno, Y; Yashiro, A; Nakashima, Y; Kuroiwa, A

    1995-08-01

    We evaluated the effects of systolic anterior motion systolic anterior motion of the mitral valve on cardiac haemodynamics. Seven adult mongrel dogs in which systolic anterior motion-septal contact was observed after dobutamine administration were used. To exclude the effects of left ventricular function and morphology, a stone removal basket catheter was placed in the left ventricular outflow tract, and haemodynamics were compared with the basket closed and opened. The basket was opened five times in three dogs not showing systolic anterior motion-septal contact, but the basket itself did not effect the haemodynamics. In the seven dogs that showed systolic anterior motion-septal contact without left ventricular hypertrophy, the basket was opened a total of 33 times in the presence of various degrees of systolic anterior motion-septal contact. After opening the basket, systolic anterior motion was reduced echocardiographically, and significant (P<0.01) changes were observed in the left ventricle-aorta pressure gradient (from 68 +/- 22 to 25 +/- 15 mm Hg), the systolic ejection period (from 146 +/- 19 to 135 +/- 16 ms), and the stroke volume (SV; from 9.4 +/- 2.9 to 10.1 +/- 3.3 ml). After basket inflation, aortic pressure and aortic flow waveforms changed but the peak pressure and flow velocity did not. The temporal distribution of left ventricular ejection also definitely changed after the basket was opened. No changes were observed in the peak dp/dt, peak negative dp/dt, time constant, left ventricular end-diastolic pressure, or left atrial pressure. These observations in this animal model of systolic anterior motion without left ventricular hypertrophy suggest that: (1) there is no potential for generation of an intra-cavity gradient in the absence of systolic anterior motion of the mitral valve, so that (2) systolic anterior motion narrowed the left ventricular outflow tract and, consequently, produced the systolic ejection period, and affected the left

  14. Interaction between left ventricular twist mechanics and arterial haemodynamics during localised, non-metabolic hyperaemia with and without blood flow restriction.

    PubMed

    van Mil, Anke C C M; Pearson, James; Drane, Aimee L; Cockcroft, John R; McDonnell, Barry J; Stöhr, Eric J

    2016-04-01

    What is the central question of this study? Left ventricular (LV) twist is reduced when afterload is increased, but the meaning of this specific heart muscle response and its impact on cardiac output are not well understood. What is the main finding and its importance? This study shows that LV twist responds even when arterial haemodynamics are altered only locally, and without apparent change in metabolic (i.e. heat-induced) demand. The concurrent decline in cardiac output and LV twist during partial arterial occlusion despite the increased peripheral demand caused by heat stress suggests that LV twist may be involved in the protective sensing of heart muscle stress that can override the provision of the required cardiac output. Whether left ventricular (LV) twist and untwisting rate (LV twist mechanics) respond to localised, peripheral, non-metabolic changes in arterial haemodynamics within an individual's normal afterload range is presently unknown. Furthermore, previous studies indicate that LV twist mechanics may override the provision of cardiac output, but this hypothesis has not been examined purposefully. Therefore, we acutely altered local peripheral arterial haemodynamics in 11 healthy humans (women/men n = 3/8; age 26 ± 5 years) by bilateral arm heating (BAH). Ultrasonography was used to examine arterial haemodynamics, LV twist mechanics and the twist-to-shortening ratio (TSR). To determine the arterial function-dependent contribution of LV twist mechanics to cardiac output, partial blood flow restriction to the arms was applied during BAH (BAHBFR ). Bilateral arm heating increased arm skin temperatures [change (Δ) +6.4 ± 0.9°C, P < 0.0001] but not core temperature (Δ -0.0 ± 0.1°C, P > 0.05), concomitant to increases in brachial artery blood flow (Δ 212 ± 77 ml, P < 0.0001), cardiac output (Δ 495 ± 487 l min(-1) , P < 0.05), LV twist (Δ 3.0 ± 3.5 deg, P < 0.05) and TSR (Δ 3.3 ± 1.3, P < 0.05) but

  15. ZnO Film Bulk Acoustic Resonator for the Kinetics Study of Human Blood Coagulation

    PubMed Central

    Chen, Da; Zhang, Zhen; Ma, Jilong; Wang, Wei

    2017-01-01

    Miniaturized and rapid blood coagulation assay technologies are critical in many clinical settings. In this paper, we present a ZnO film bulk acoustic resonator for the kinetic analysis of human blood coagulation. The resonator operated in thickness shear resonance mode at 1.4 GHz. When the resonator contacted the liquid environment, the viscous loading effect was considered as the additional resistance and inductance in the equivalent circuits, resulting in a linear relationship with a slope of approximately −217 kHz/cP between the liquid viscosity and the frequency of the resonator. The downshift of the resonant frequency and the viscosity change during the blood coagulation were correlated to monitor the coagulation process. The sigmoidal trend was observed in the frequency response for the blood samples activated by thromboplastin and calcium ions. The coagulation kinetics involving sequential phases of steady reaction, growth and saturation were revealed through the time-dependent frequency profiles. The enzymatic cascade time, the coagulation rate, the coagulation time and the clot degree were provided by fitting the time-frequency curves. The prothrombin times were compared with the results measured by a standard coagulometer and show a good correlation. Thanks to the excellent potential of integration, miniaturization and the availability of direct digital signals, the film bulk acoustic resonator has promising application for both clinical and personal use coagulation testing technologies. PMID:28467374

  16. Curcumin, hemostasis, thrombosis, and coagulation.

    PubMed

    Keihanian, Faeze; Saeidinia, Amin; Bagheri, Ramin Khameneh; Johnston, Thomas P; Sahebkar, Amirhossein

    2018-06-01

    Atherothrombotic cardiovascular disease is a major cause of mortality throughout the world. Platelet activation and aggregation play a central role in hemostasis and thrombosis. Herbal medicines have been traditionally used in the management of cardiovascular disease and can help in modifying its progression, particularly in hemostasis and the coagulation process, as well as altering platelet function tests and some coagulation parameters. Curcumin is a polyphenol derived from the Curcuma longa plant and has been used extensively in complementary and alternative medicine, as it is nontoxic and safe with various therapeutic properties. Modern scientific research has demonstrated its anti-inflammatory, antioxidant, anti-carcinogenic, antithrombotic, and cardiovascular protective effects. The present study reviewed previous studies in the literature, which support the positive activity of curcumin in hemostasis, anticoagulation, and fibrinolysis. We also presented molecular mechanisms associated with the antiplatelet and anticoagulant activities of curcumin and potential implications for the treatment of cardiovascular disease. © 2017 Wiley Periodicals, Inc.

  17. Performance optimization of coagulant/flocculant in the treatment of wastewater from a beverage industry.

    PubMed

    Amuda, O S; Amoo, I A; Ajayi, O O

    2006-02-28

    This study investigated the effect of coagulation/flocculation treatment process on wastewater of Fumman Beverage Industry, Ibadan, Nigeria. The study also compared different dosages of coagulant, polyelectrolyte (non-ionic polyacrylamide) and different pH values of the coagulation processes. The effect of different dosages of polyelectrolyte in combination with coagulant was also studied. The results reveal that low pH values (3-8), enhance removal efficiency of the contaminants. Percentage removal of 78, 74 and 75 of COD, TSS and TP, respectively, were achieved by the addition of 500 mg/L Fe2(SO4)3.3H2O and 93, 94 and 96% removal of COD, TSS and TP, respectively, were achieved with the addition of 25 mg/L polyelectrolyte to the coagulation process. The volume of sludge produced, when coagulant was used solely, was higher compared to the use of polyelectrolyte combined with Fe2(SO4)3.3H2O. This may be as a result of non-ionic nature of the polyelectrolyte; hence, it does not chemically react with solids of the wastewater. Coagulation/flocculation may be useful as a pre-treatment process for beverage industrial wastewater prior to biological treatment.

  18. Dielectric permittivity change detects the process of blood coagulation: Comparative study of dielectric coagulometry with rotational thromboelastometry.

    PubMed

    Otaki, Yoichi; Ebana, Yusuke; Yoshikawa, Shunji; Isobe, Mitsuaki

    2016-09-01

    Intravascular thrombus formation causes various cardiovascular diseases. To monitor coagulation is important for screening native status, prevention from bleeding and maintaining it within its therapeutic range. The prothrombin time and the activated partial thromboplastin time are widely used for assessment and recognized as the conventional methods. Prothrombin time methods employ enhancement of coagulation with thromboplastin. Since the laboratory data depend on the production lot and/or the manufacturer, the accurate methods are required for evaluation. Rotational thromboelastometry (ROTEM) is a method based on detection of the change in resistance to rotational movement during blood clotting, while dielectric blood coagulometry (DBCM) is a novel method for assessment of clotting by measuring the change of electrical permittivity. These methods are thus based on the technology for observation of different physical phenomena. The aim of this study was to compare parameters such as the clotting time obtained by ROTEM and DBCM to evaluate their clinical usefulness. ROTEM and DBCM parameters were measured in 128 patients. The ROTEM clotting time showed a significant positive correlation with the DBCM coagulation time (R=0.707, p<0.001). Comparison of the DBCM coagulation time between patients with and without anticoagulant therapy (including novel oral anticoagulants) revealed a significant difference (43.8±11.9min in the anticoagulant group vs 29.4±8.3min in the control group, p<0.001). Evaluation of coagulation was equivalent with DBCM and ROTEM. The present study suggested that DBCM, a novel method for measuring blood clotting, could provide the detail assessment for the status of anticoagulant therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Structure and dynamics of zymogen human blood coagulation factor X.

    PubMed

    Venkateswarlu, Divi; Perera, Lalith; Darden, Tom; Pedersen, Lee G

    2002-03-01

    The solution structure and dynamics of the human coagulation factor X (FX) have been investigated to understand the key structural elements in the zymogenic form that participates in the activation process. The model was constructed based on the 2.3-A-resolution x-ray crystallographic structure of active-site inhibited human FXa (PDB:1XKA). The missing gamma-carboxyglutamic acid (GLA) and part of epidermal growth factor 1 (EGF1) domains of the light chain were modeled based on the template of GLA-EGF1 domains of the tissue factor (TF)-bound FVIIa structure (PDB:1DAN). The activation peptide and other missing segments of FX were introduced using homology modeling. The full calcium-bound model of FX was subjected to 6.2 ns of molecular dynamics simulation in aqueous medium using the AMBER6.0 package. We observed significant reorientation of the serine-protease (SP) domain upon activation leading to a compact multi-domain structure. The solution structure of zymogen appears to be in a well-extended conformation with the distance between the calcium ions in the GLA domain and the catalytic residues estimated to be approximately 95 A in contrast to approximately 83 A in the activated form. The latter is in close agreement with fluorescence studies on FXa. The S1-specificity residues near the catalytic triad show significant differences between the zymogen and activated structures.

  20. Does extubation result in haemodynamic instability in patients following coronary artery bypass grafts?

    PubMed

    Walthall, H; Ray, S; Robson, D

    2001-10-01

    Coronary heart disease and its management continue to be at the centre of Government health policy. The present political climate demands clinical effectiveness and best practice should be established, while maintaining the philosophy of cost-effectiveness and resource management. These directives have led practitioners to question the care of patients following coronary artery bypass surgery, in particular the role of mechanical ventilation and the subsequent act of extubation. A retrospective study of 89 patients who had coronary artery bypass grafts (emergency and elective) was undertaken, to establish if extubation had a significant effect on the haemodynamic status of patients with variable degrees of left ventricular function (19% with poor left ventricular function). The study found that extubation was achieved within a mean time of 4.97 hours following return from surgery. Extubation resulted in a significant increase in heart rate (P = 0.001), as well as a respiratory acidosis (pCO2: P = 0.000; pH: P = 0.000). However, the stability of the patient was not compromised, with neither mean arterial blood pressure (P = 0.825) nor oxygenation levels (P = 0.267) being significantly altered by extubation. On multivariate analysis, the act of extubation had no significant effect on any of the dependent variables. These results suggest that it is not extubation alone that has an impact on the haemodynamic stability of patients following coronary artery bypass grafts, but that this is indeed multifactorial. Therefore extubation is 'safe' practice for patients with varying degrees of left ventricular function following coronary artery bypass grafts. Limitations of the study are acknowledged.

  1. Laparoscopic management of retroperitoneal injuries from penetrating abdominal trauma in haemodynamically stable patients.

    PubMed

    Koto, Modise Zacharia; Matsevych, Oleh Y; Mosai, Fusi; Balabyeki, Moses; Aldous, Colleen

    2018-02-27

    Laparoscopy is increasingly utilised in the trauma setting. However, its safety and reliability in evaluating and managing retroperitoneal injuries are not known. The aim of this study was to analyse our experience with laparoscopic management of retroperitoneal injuries due to penetrating abdominal trauma (PAT) and to investigate its feasibility, safety and accuracy in haemodynamically stable patients. Over a 4-year period, patients approached laparoscopically with retroperitoneal injuries were analysed. Mechanism, location and severity of injuries were recorded. Surgical procedures, conversion rate and reasons for conversion and outcomes were described. Of the 284 patients with PAT, 56 patients had involvement of retroperitoneum. Stab wounds accounted 62.5% of patients. The mean Injury Severity Score was 7.4 (4-20). Among retroperitoneal injuries, the colon (27%) was the most commonly involved hollow viscera followed by duodenum (5%). The kidney (5%) and the pancreas (4%) were the injured solid organs. The conversion rate was 19.6% and was mainly due to active bleeding (73%). Significantly more patients with gunshot wound were converted to laparotomy (38% vs. 9%). Therapeutic laparoscopy was performed in 36% of patients. There were no recorded missed injuries or mortality. Five (9%) patients developed the Clavien-Dindo Grade 3 complications, three were managed with reoperation, one with drainage/debridement and one with endovascular technique. Laparoscopic management of retroperitoneal injuries is safe and feasible in haemodynamically stable patients with PAT. However, a high conversion rate indicates difficulties in managing these injuries. The requirements are the dexterity in laparoscopy and readiness to convert in the event of bleeding.

  2. Facing emotions in narcolepsy with cataplexy: haemodynamic and behavioural responses during emotional stimulation.

    PubMed

    de Zambotti, Massimiliano; Pizza, Fabio; Covassin, Naima; Vandi, Stefano; Cellini, Nicola; Stegagno, Luciano; Plazzi, Giuseppe

    2014-08-01

    Narcolepsy with cataplexy is a complex sleep disorder that affects the modulation of emotions: cataplexy, the key symptom of narcolepsy, is indeed strongly linked with emotions that usually trigger the episodes. Our study aimed to investigate haemodynamic and behavioural responses during emotional stimulation in narco-cataplexy. Twelve adult drug-naive narcoleptic patients (five males; age: 33.3 ± 9.4 years) and 12 healthy controls (five males; age: 30.9 ± 9.5 years) were exposed to emotional stimuli (pleasant, unpleasant and neutral pictures). Heart rate, arterial blood pressure and mean cerebral blood flow velocity of the middle cerebral arteries were continuously recorded using photoplethysmography and Doppler ultrasound. Ratings of valence and arousal and coping strategies were scored by the Self-Assessment Manikin and by questionnaires, respectively. Narcoleptic patients' haemodynamic responses to pictures overlapped with the data obtained from controls: decrease of heart rate and increase of mean cerebral blood flow velocity regardless of pictures' content, increase of systolic blood pressure during the pleasant condition, and relative reduction of heart rate during pleasant and unpleasant conditions. However, when compared with controls, narcoleptic patients reported lower arousal scores during the pleasant and neutral stimulation, and lower valence scores during the pleasant condition, respectively, and also a lower score at the 'focus on and venting of emotions' dimensions of coping. Our results suggested that adult narcoleptic patients, compared with healthy controls, inhibited their emotion-expressive behaviour to emotional stimulation, and that may be related to the development of adaptive cognitive strategies to face emotions avoiding cataplexy. © 2014 European Sleep Research Society.

  3. Effect of intravenous infusion of dexmedetomidine on perioperative haemodynamic changes and postoperative recovery: A study with entropy analysis

    PubMed Central

    Patel, Chirag Ramanlal; Engineer, Smita R; Shah, Bharat J; Madhu, S

    2012-01-01

    Background: Dexmedetomidine, an α2 agonist, when used as an adjuvant in general anaesthesia attenuates stress response to various noxious stimuli, maintains perioperative haemodynamic stability and provides sedation without significant respiratory depression postoperatively. Methods: Sixty patients were randomly divided into two groups of 30 each. In group A, fentanyl 2 μg/kg and in group B dexmedetomidine were given intravenously as loading dose of 1 μg/kg over 10 min prior to induction. After induction with thiopentone, in group B, dexmedetomidine was given as infusion at a dose of 0.2–0.8 μg/kg. Sevoflurane was used as inhalation agent in both groups. Haemodynamic variables and entropy (response entropy and state entropy) were recorded continuously. Postoperative sedation and recovery were assessed by sedation score and modified Aldrete's score, respectively. Results: Dexmedetomidine significantly attenuates stress response at intubation with lesser increase in heart rate (10% vs. 17%), systolic blood pressure (6% vs. 23%) and diastolic blood pressure (7% vs. 20%) as compared to the control group (P<0.05). Intraoperatively, an average of 8% fall in systolic blood pressure and 8.16% fall in diastolic pressure in the test group as compared to 3.6% rise in systolic and 3.3% in diastolic pressure of the control group was observed. Postoperatively, the test group showed significant sedation at 2 h as compared to the control group (P=0.00) and recovery was better in the control group for the first 2 h post extubation. Conclusion: Dexmedetomidine attenuates various stress responses during surgery and maintains the haemodynamic stability when used as an adjuvant in general anaesthesia. Also, the sedative action of dexmedetomidine delays recovery for the first few hours post extubation. PMID:23325938

  4. Comparison of the level of residual coagulant activity in different cheese varieties.

    PubMed

    Bansal, Nidhi; Fox, Patrick F; McSweeney, Paul L H

    2009-08-01

    The coagulant retained in cheese curd is a major contributor to proteolysis during ripening. The objective of this study was to quantify residual coagulant in 9 cheese varieties by measuring its activity on a synthetic heptapeptide (Pro-Thr-Glu-Phe-[NO2-Phe]-Arg-Leu) assayed using reversed-phase HPLC. The level of residual coagulant activity was highest in Camembert cheese, probably due to its low pH at whey drainage and the high moisture content of the cheese, followed in order by Feta=Port du Salut=Cheddar>Gouda>Emmental=Parmigiano Reggiano=low-moisture part-skim Mozzarella=Mozzarella di Bufala Campana. The high cooking temperature (50-54 degrees C) used during the manufacture of Emmental and Parmigiano Reggiano cheeses and the cooking and stretching step in hot water during the manufacture of Mozzarella cheese may be the reasons for the lowest residual coagulant activity in these cheeses. The level of residual coagulant activity was higher in Feta cheese made from milk concentrated by ultrafiltration than in conventional Feta.

  5. The influence of excipients commonly used in freeze drying on whole blood coagulation dynamics assessed by rotational thromboelastometry.

    PubMed

    Erber, Matthias; Lee, Geoffrey

    2015-09-01

    Lyophilized reagents are used on a daily basis in coagulation diagnostics. They often contain a number of excipients in addition to the active compound. Some of these excipients may, however, influence coagulation dynamics. Besides from plasmatic coagulation bulking agents may influence platelet properties. We therefore studied the influence of a variety of bulking agents (glycine, mannitol, sucrose and trehalose) as well as a surfactant (Tween® 80) on whole blood coagulation using thromboelastometry (ROTEM®) and platelet function analysis (ROTEM® platelet). Both disaccharides as well as Tween® 80 did not influence whole blood coagulation in the concentration range investigated. The addition of glycine and mannitol solutions to the ROTEM® measurement leads to an impaired clot formation as well as overall clot strength while clotting initiation remained barely influenced. Hypertonic glycine and mannitol solutions exhibit different clot formation impairment when correlated to their osmolar concentration and compared to equally osmolar NaCl-solutions. The effect of glycine was assigned to fibrin formation impairment identified with the FIBTEM assay. Platelet function analysis revealed that hypertonic glycine solutions do not alter platelet function but hypertonic mannitol and NaCl solutions do. While the influence observed for glycine may be due to fibrinogen precipitation, the mechanism of mannitol appears to be more complex as platelet function as well as fibrin-based clot formation are influenced. This study therefore demonstrates the necessity to check for coagulation impairment due to compounds contained in lyophilized reagents.

  6. Decolorization and COD reduction of dyeing wastewater from a cotton textile mill using thermolysis and coagulation.

    PubMed

    Kumar, Pradeep; Prasad, B; Mishra, I M; Chand, Shri

    2008-05-01

    The decolorization and reduction of COD of dyeing wastewater from a cotton textile mill was conducted using catalytic thermal treatment (thermolysis) accompanied with/without coagulation. Thermolysis in presence of a homogeneous copper sulphate catalyst was found to be the most effective in comparison to other catalysts (FeCl(3), FeSO(4), CuO, ZnO and PAC) used. A maximum reduction of chemical oxygen demand (COD) and color of dyeing wastewater of 66.85% and 71.4%, respectively, was observed with a catalyst concentration of 5 kg/m(3) at pH 8. Commercial alum was found most effective coagulant among various coagulants (aluminum potassium sulphate, PAC, FeCl(3) and FeSO(4)) tested during coagulation operations, resulting in 58.57% COD and 74% color reduction at pH 4 and coagulant dose of 5 kg/m(3). Coagulation of the clear fluid (supernatant) obtained after treatment by thermolysis at the conditions previously used resulted in an overall reduction of 89.91% COD and 94.4% color at pH 4 and a coagulant dose of 2 kg/m(3). The application of thermolysis followed by coagulation, thus, is the most effective treatment method in removing nearly 90% COD and 95% color at a lower dose of coagulant (2 kg/m(3)). The sludge thus produced would contain lower inorganic mass coagulant and, therefore, less amount of inorganic sludge.

  7. Effects of storage conditions of Moringa oleifera seeds on its performance in coagulation.

    PubMed

    Katayon, S; Noor, M J Megat Mohd; Asma, M; Ghani, L A Abdul; Thamer, A M; Azni, I; Ahmad, J; Khor, B C; Suleyman, A M

    2006-09-01

    Moringa oleifera is a plant whose seeds have coagulation properties for treating water and wastewater. In this study the coagulation efficiency of Moringa oleifera kept in different storage conditions were studied. The Moringa oleifera seeds were stored at different conditions and durations; open container and closed container at room temperature (28 degrees C) and refrigerator (3 degrees C) for durations of 1, 3 and 5 months. Comparison between turbidity removal efficiency of Moringa oleifera kept in refrigerator and room temperature revealed that there was no significant difference between them. The Moringa oleifera kept in refrigerator and room temperature for one month showed higher turbidity removal efficiency, compared to those kept for 3 and 5 months, at both containers. The coagulation efficiency of Moringa oleifera was found to be dependent on initial turbidity of water samples. Highest turbidity removals were obtained for water with very high initial turbidity. In summary coagulation efficiency of Moringa oleifera was found independent of storage temperature and container, however coagulation efficiency of Moringa oleifera decreased as storage duration increased. In addition, Moringa oleifera can be used as a potential coagulant especially for very high turbidity water.

  8. Structural bioinformatics: methods, concepts and applications to blood coagulation proteins.

    PubMed

    Villoutreix, Bruno O

    2002-06-01

    Structural and theoretical analyses of proteins are central to the understanding of complex molecular mechanisms and are fundamental to the drug discovery process. Computational techniques yield useful insights into an ever-wider range of biomolecular systems. Protein three-dimensional structures and molecular functions can be predicted in some circumstances, while experimental structures can be analyzed in depth via such computational approaches. Non-covalent binding of biomolecules can be understood by considering structural, thermodynamic and kinetic issues, and theoretical simulations of such events can be attempted. The central role of electrostatic interactions with regard to protein function, structure and stability has been investigated and some electrostatic properties can be modeled theoretically. Computer methods thus help to prioritize, design, analyze and rationalize biochemical experiments. Cardiovascular diseases and associated blood coagulation disorders are leading causes of death worldwide. Blood coagulation involves more than 30 proteins that interact specifically with various degrees of affinity. Many of these molecules can also bind transiently to phospholipid surfaces. Numerous point mutations in the genes of coagulation proteins and regulators have been identified. Understanding the coagulation cascade, its regulation and the impact of mutations is required for the development of new therapies and diagnostic tools. In this review, we describe concepts and methods pertaining to the field of structural bioinformatics. We provide examples of applications of these approaches to blood coagulation proteins and show that such studies can give insights about molecular mechanisms contributing to cardiovascular disease susceptibility.

  9. Improving primary treatment of urban wastewater with lime-induced coagulation.

    PubMed

    Marani, Dario; Ramadori, Roberto; Braguglia, Camilla Maria

    2004-01-01

    The enhancement of primary treatment efficiency through the coagulation process may yield several advantages, including lower aeration energy in the subsequent biological unit and higher recovery of biogas from sludge digestion. In this work sewage coagulation with lime was studied at pilot plant level, using degritted sewage from the city of Rome. The work aimed at optimising the operating conditions (coagulant dosage or treatment pH, and mixing conditions in the coagulation and flocculation tanks), in order to maximise the efficiency of suspended Chemical Oxygen Demand (COD) removal and to minimise sludge production. Lime dosage optimisation resulted in an optimal treatment pH of 9. Lime addition up to pH 9 may increase COD removal rate in the primary treatment from typical 30-35% of plain sedimentation up to 55-70%. Within the velocity gradients experimented in this work (314-795 s(-1) for the coagulation tank and 13-46 s(-1) for the flocculation tank), mixing conditions did not significantly affect the lime-enhanced process, which seems to be controlled by slow lime dissolution. Sludge produced in the lime-enhanced process settled and compacted easily, inducing an average 36% decrease in sludge volume with respect to plain settling. However excess sludge was produced, which was not accounted for by the amount of suspended solids removed. This is probably due to incomplete dissolution of lime, which may be partially incorporated in the sludge.

  10. Effect of fibrinogen on blood coagulation detected by optical coherence tomography.

    PubMed

    Xu, Xiangqun; Teng, Xiangshuai

    2015-05-21

    Our previous work demonstrated that an optical coherence tomography (OCT) technique and the parameter 1/e light penetration depth (d1/e) were able to characterize the whole blood coagulation process in contrast to existing optical tests that are performed on plasma samples. To evaluate the feasibility of the technique for quantifying the effect of fibrinogen (Fbg) on blood coagulation, a dynamic study of d1/e of blood in various Fbg concentrations was performed in static state. Two groups of blood samples of hematocrit (HCT) in 35, 45, and 55% were reconstituted of red blood cells with: 1) treated plasma with its intrinsic Fbg removed and commercial Fbg added (0-8 g L(-1)); and 2) native plasma with commercial Fbg added (0-8 g L(-1)). The results revealed a typical behavior due to coagulation induced by calcium ions and the clotting time is Fbg concentration-dependent. The clotting time was decreased by the increasing amount of Fbg in both groups. Besides, the blood of lower HCT with various levels of Fbg took shorter time to coagulate than that of higher HCT. Consequently, the OCT method is a useful and promising tool for the detection of blood-coagulation processes induced with different Fbg levels.

  11. Incorporating radioactive decay into charging and coagulation of multicomponent radioactive aerosols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Yong-ha; Yiacoumi, Sotira; Nenes, Athanasios

    Compositional changes by the decay of radionuclides in radioactive aerosols can influence their charging state, coagulation frequency and size distribution throughout their atmospheric lifetime. The importance of such effects is unknown as they have not been considered in microphysical and global radioactivity transport studies to date. Here, we explore the effects of compositional changes on the charging efficiency and coagulation rates of aerosols using a set of kinetic equations that couple all relevant processes (decay, charging and coagulation) and their evolution over time. Compared to a coupled aggregation-tracer model for the prediction of the radioactive composition of particulates undergoing coagulation,more » our kinetic approach can provide similar results using much less central processing unit time. Altogether with other considerations, our approach is computational efficient enough to allow implementation in 3D atmospheric transport models. The decay of radionuclides and the production of decay products within radioactive aerosols may significantly affect the aerosol charging rates, and either hinder or promote the coagulation of multicomponent radioactive aerosols. Our results suggest that radiological phenomena occurring within radioactive aerosols, as well as subsequent effects on aerosol microphysics, should be considered in regional and global models to more accurately predict radioactivity transport in the atmosphere in case of a nuclear plant accident.« less

  12. Incorporating radioactive decay into charging and coagulation of multicomponent radioactive aerosols

    DOE PAGES

    Kim, Yong-ha; Yiacoumi, Sotira; Nenes, Athanasios; ...

    2017-09-29

    Compositional changes by the decay of radionuclides in radioactive aerosols can influence their charging state, coagulation frequency and size distribution throughout their atmospheric lifetime. The importance of such effects is unknown as they have not been considered in microphysical and global radioactivity transport studies to date. Here, we explore the effects of compositional changes on the charging efficiency and coagulation rates of aerosols using a set of kinetic equations that couple all relevant processes (decay, charging and coagulation) and their evolution over time. Compared to a coupled aggregation-tracer model for the prediction of the radioactive composition of particulates undergoing coagulation,more » our kinetic approach can provide similar results using much less central processing unit time. Altogether with other considerations, our approach is computational efficient enough to allow implementation in 3D atmospheric transport models. The decay of radionuclides and the production of decay products within radioactive aerosols may significantly affect the aerosol charging rates, and either hinder or promote the coagulation of multicomponent radioactive aerosols. Our results suggest that radiological phenomena occurring within radioactive aerosols, as well as subsequent effects on aerosol microphysics, should be considered in regional and global models to more accurately predict radioactivity transport in the atmosphere in case of a nuclear plant accident.« less

  13. A survey of coagulation laboratory practices and satisfaction ratings of member laboratories of the Thailand National External Quality Assessment Scheme for blood coagulation.

    PubMed

    Chuntarut, A; Tientadakul, P; Wongkrajang, P

    2016-06-01

    The Thailand National External Quality Assessment Scheme (NEQAS) for blood coagulation was established in 2005. The objective of this study was to collect data of coagulation laboratory practices and satisfaction of NEQAS member. Two hundred seventy-six questionnaires were sent to laboratories that are members of NEQAS to obtain data relating to coagulation laboratory practice and satisfaction in 2014. Data from this survey were compared with data from the survey conducted in 2005 to evaluate levels of improvement. Of 276 questionnaires sent, 212 (76.8%) were returned. Improvements were characterized by the number of laboratories that (i) decreased use of 3.8% sodium citrate as anticoagulant; (ii) implemented use of at least two control levels for internal quality control; and (iii) implemented reporting of reference values with results, as well as establishing their own reference range and using geometric mean as the denominator for international normalized ratio calculation. For overall satisfaction, 179 of 206 (86.9%) participant laboratories reported being satisfied or very satisfied. Improvements in coagulation laboratory practices in Thailand were observed in every step of the total testing process. However, additional improvements are still needed, such as determination and use of a local reference range. © 2016 John Wiley & Sons Ltd.

  14. Lung recruitment manoeuvres do not cause haemodynamic instability or oxidative stress but improve oxygenation and lung mechanics in a newborn animal model: an observational study.

    PubMed

    de la Osa, Agustín Mendiola; Garcia-Fernandez, Javier; Llorente-Cantarero, Francisco J; Gil-Campos, Mercedes; Muñoz-Villanueva, María C; De la Torre Aguilar, María J; de la Rosa, Ignacio Ibarra; Pérez-Navero, Juan L

    2014-09-01

    Lung recruitment manoeuvres in neonates during anaesthesia are not performed routinely due to concerns about causing barotrauma, haemodynamic instability and oxidative stress. To assess the influence of recruitment manoeuvres and positive end-expiratory pressure (PEEP) on haemodynamics, oxidative stress, oxygenation and lung mechanics. A prospective experimental study. Experimental Unit, La Paz University Hospital, Madrid, Spain. Eight newborn piglets (<48 h) with healthy lungs under general anaesthesia. The recruitment manoeuvres in pressure-controlled ventilation (PCV) were performed along with a constant driving pressure of 15 cmH2O. After the recruitment manoeuvres, PEEP was reduced in a stepwise fashion to find the maximal dynamic compliance step (maxCDyn-PEEP). Blood oxidative stress biomarkers (lipid peroxidation products, protein carbonyls, total glutathione, oxidised glutathione, reduced glutathione and activity of glutathione peroxidase) were analysed. Haemodynamic parameters, arterial partial pressure of oxygen (paO2), tidal volume (Vt), dynamic compliance (Cdyn) and oxidative stress biomarkers were measured. The recruitment manoeuvres did not induce barotrauma. Haemodynamic instability was not detected either in the maximum pressure step (overdistension step 5) or during the entire process. No substantial differences were observed in blood oxidative stress parameters analysed as compared with their baseline values (with 0 PEEP) or the values obtained 180 min after the onset of the recruitment manoeuvres (optimal PEEP). Significant maximal values were achieved in step 14 with an increase in paO2 (32.43 ± 8.48 vs. 40.39 ± 15.66 kPa; P = 0.037), Vt (47.75 ± 13.59 vs. 73.87 ± 13.56 ml; P = 0.006) and Cdyn (2.50 ± 0.64 vs. 4.75 ± 0.88 ml cmH2O; P < 0.001). Maximal dynamic compliance step (maxCdyn-PEEP) was 2 cmH2O. Recruitment manoeuvres in PCV with a constant driving pressure are a well tolerated open

  15. Thermal Ablation by High-Intensity-Focused Ultrasound Using a Toroid Transducer Increases the Coagulated Volume and Allows Coagulation Near Portal and Hepatic veins in Pigs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Melodelima, D.; N'Djin, W. A.; Parmentier, H.

    2009-04-14

    A new geometry of HIFU transducer is described to enlarge the coagulated volume. The geometry of the transducer was not spherical. The surface of the transducer was built based on a toroid geometry. The transducer was generated by the revolution of a circle about an axis lying in its plane. Eight emitters operating at a frequency of 3 MHz were diced out of a single toroid piezocomposite element. Each of the eight emitters was divided into 32 transducers. The focal zone is conical and located at 70 mm from the transducer. A 7.5 MHz ultrasound imaging probe is placed inmore » the centre of the device for guiding the treatment. Our long-term objective is to develop a device that can be used during surgery. In vivo trials have been performed on 13 pigs to demonstrate this new principle and to evaluate the vascular tolerance of the treatment. This new geometry combined with consecutive activation of the eight emitters around the toroid allows achieving a mean thermal ablation of 7.0{+-}2.5 cm3 in 40 seconds. All lesions were visible with high contrast on sonograms. The correlation between the size of lesions observed on sonograms and during gross examination was 92%. This allows the user to easily enlarge the coagulated volume by juxtaposing single lesions. The pigs tolerate the treatment well over the experimental period even when coagulation was produced through portal and/or hepatic veins.« less

  16. pyNS: an open-source framework for 0D haemodynamic modelling.

    PubMed

    Manini, Simone; Antiga, Luca; Botti, Lorenzo; Remuzzi, Andrea

    2015-06-01

    A number of computational approaches have been proposed for the simulation of haemodynamics and vascular wall dynamics in complex vascular networks. Among them, 0D pulse wave propagation methods allow to efficiently model flow and pressure distributions and wall displacements throughout vascular networks at low computational costs. Although several techniques are documented in literature, the availability of open-source computational tools is still limited. We here present python Network Solver, a modular solver framework for 0D problems released under a BSD license as part of the archToolkit ( http://archtk.github.com ). As an application, we describe patient-specific models of the systemic circulation and detailed upper extremity for use in the prediction of maturation after surgical creation of vascular access for haemodialysis.

  17. Short communication: influence of composite casein genotypes on additive genetic variation of milk production traits and coagulation properties in Holstein-Friesian cows.

    PubMed

    Penasa, M; Cassandro, M; Pretto, D; De Marchi, M; Comin, A; Chessa, S; Dal Zotto, R; Bittante, G

    2010-07-01

    The aim of the study was to quantify the effects of composite beta- and kappa-casein (CN) genotypes on genetic variation of milk coagulation properties (MCP); milk yield; fat, protein, and CN contents; somatic cell score; pH; and titratable acidity (TA) in 1,042 Italian Holstein-Friesian cows. Milk coagulation properties were defined as rennet coagulation time (RCT) and curd firmness (a(30)). Variance components were estimated using 2 animal models: model 1 included herd, days in milk, and parity as fixed effects and animal and residual as random effects, and model 2 was model 1 with the addition of composite beta- and kappa-CN genotype as a fixed effect. Genetic correlations between RCT and a(30) and between these traits and milk production traits were obtained with bivariate analyses, based on the same models. The inclusion of casein genotypes led to a decrease of 47, 68, 18, and 23% in the genetic variance for RCT, a(30), pH, and TA, respectively, and less than 6% for other traits. Heritability of RCT and a(30) decreased from 0.248 to 0.143 and from 0.123 to 0.043, respectively. A moderate reduction was found for pH and TA, whereas negligible changes were detected for other milk traits. Estimates of genetic correlations were comparable between the 2 models. Results show that composite beta- and kappa-CN genotypes are important for RCT and a(30) but cannot replace the recording of MCP themselves. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  18. Surface-mediated molecular events in material-induced blood-plasma coagulation

    NASA Astrophysics Data System (ADS)

    Chatterjee, Kaushik

    Coagulation and thrombosis persist as major impediments associated with the use of blood-contacting medical devices. We are investigating the molecular mechanism underlying material-induced blood-plasma coagulation focusing on the role of the surface as a step towards prospective development of improved hemocompatible biomaterials. A classic observation in hematology is that blood/blood-plasma in contact with clean glass surface clots faster than when in contact with many plastic surfaces. The traditional biochemical theory explaining the underlying molecular mechanism suggests that hydrophilic surfaces, like that of glass, are specific activators of the coagulation cascade because of the negatively-charged groups on the surface. Hydrophobic surfaces are poor procoagulants or essentially "benign" because they lack anionic groups. Further, these negatively-charged surfaces are believed to not only activate blood factor XII (FXII), the key protein in contact activation, but also play a cofactor role in the amplification and propagation reactions that ultimately lead to clot formation. In sharp contrast to the traditional theory, our investigations indicate a need for a paradigm shift in the proposed sequence of contact activation events to incorporate the role of protein adsorption at the material surfaces. These studies have lead to the central hypothesis for this work proposing that protein adsorption to hydrophobic surfaces attenuates the contact activation reactions so that poorly-adsorbent hydrophilic surfaces appear to be stronger procoagulants relative to hydrophobic surfaces. Our preliminary studies measuring the plasma coagulation response of activated FXII (FXIIa) on different model surfaces suggested that the material did not play a cofactor role in the processing of this enzyme dose through the coagulation pathway. Therefore, we focused our efforts on studying the mechanism of initial production of enzyme at the procoagulant surface. Calculations for the

  19. Patterned retinal coagulation with a scanning laser

    NASA Astrophysics Data System (ADS)

    Palanker, Daniel; Jain, ATul; Paulus, Yannis; Andersen, Dan; Blumenkranz, Mark S.

    2007-02-01

    Pan-retinal photocoagulation in patients with diabetic retinopathy typically involves application of more than 1000 laser spots; often resulting in physician fatigue and patient discomfort. We present a semi-automated patterned scanning laser photocoagulator that rapidly applies predetermined patterns of lesions; thus, greatly improving the comfort, efficiency and precision of the treatment. Patterns selected from a graphical user interface are displayed on the retina with an aiming beam, and treatment can be initiated and interrupted by depressing a foot pedal. To deliver a significant number of burns during the eye's fixation time, each pulse should be considerably shorter than conventional 100ms pulse duration. We measured coagulation thresholds and studied clinical and histological outcomes of the application of laser pulses in the range of 1-200ms in pigmented rabbits. Laser power required for producing ophthalmoscopically visible lesions with a laser spot of 132μm decreased from 360 to 37mW with pulse durations increasing from 1 to 100ms. In the range of 10-100ms clinically and histologically equivalent light burns could be produced. The safe therapeutic range of coagulation (ratio of the laser power required to produce a rupture to that for a light burn) decreased with decreasing pulse duration: from 3.8 at 100ms, to 3.0 at 20ms, to 2.5 at 10ms, and to 1.1 at 1ms. Histology demonstrated increased confinement of the thermal damage with shorter pulses, with coagulation zone limited to the photoreceptor layer at pulses shorter than 10ms. Durations of 10-20ms appear to be a good compromise between the speed and safety of retinal coagulation. Rapid application of multiple lesions greatly improves the speed, precision, and reduces pain in retinal photocoagulation.

  20. Quinine-induced disseminated intravascular coagulation.

    PubMed

    Spearing, R L; Hickton, C M; Sizeland, P; Hannah, A; Bailey, R R

    Recurrent disseminated intravascular coagulation occurred in 3 women after ingestion of quinine tablets for cramp. All had circulating quinine-dependent antibodies to platelets and in 2 there was initial evidence of antibody consumption, with low titres that rose steeply over the next few days and remained high for many months.

  1. The Organophosphate Paraoxon and Its Antidote Obidoxime Inhibit Thrombin Activity and Affect Coagulation In Vitro

    PubMed Central

    Golderman, Valery; Shavit-Stein, Efrat; Tamarin, Ilia; Rosman, Yossi; Shrot, Shai; Rosenberg, Nurit

    2016-01-01

    Organophosphates (OPs) are potentially able to affect serine proteases by reacting with their active site. The potential effects of OPs on coagulation factors such as thrombin and on coagulation tests have been only partially characterized and potential interactions with OPs antidotes such as oximes and muscarinic blockers have not been addressed. In the current study, we investigated the in vitro interactions between coagulation, thrombin, the OP paraoxon, and its antidotes obidoxime and atropine. The effects of these substances on thrombin activity were measured in a fluorescent substrate and on coagulation by standard tests. Both paraoxon and obidoxime but not atropine significantly inhibited thrombin activity, and prolonged prothrombin time, thrombin time, and partial thromboplastin time. When paraoxon and obidoxime were combined, a significant synergistic effect was found on both thrombin activity and coagulation tests. In conclusion, paraoxon and obidoxime affect thrombin activity and consequently alter the function of the coagulation system. Similar interactions may be clinically relevant for coagulation pathways in the blood and possibly in the brain. PMID:27689805

  2. Genetic variation and effects of candidate-gene polymorphisms on coagulation properties, curd firmness modeling and acidity in milk from Brown Swiss cows.

    PubMed

    Cecchinato, A; Chessa, S; Ribeca, C; Cipolat-Gotet, C; Bobbo, T; Casellas, J; Bittante, G

    2015-07-01

    The aims of this study were to estimate the genetic variation of traditional milk coagulation properties (MCPs), milk acidity, curd firmness (CF) modeled on time t (CF(t) ; comprising: RCT(eq), rennet coagulation time estimated from the equation; CF(P), the asymptotic potential curd firmness; k(CF), the curd firming instant rate constant; and k(SR), the syneresis instant rate constant) and maximum CF traits (MCF; comprising CF(max), the maximum CF value; and tmax, the time of attainment). Furthermore, we investigated 96 single nucleotide polymorphisms (SNPs) from 54 candidate genes, testing their associations with the above-listed traits. Milk and blood samples were collected from 1271 cows (each sampled once) from 85 herds. Genotyping was performed using a custom Illumina VeraCode GoldenGate approach. A Bayesian linear animal model (including the effects of herd, days in milk, parity and additive polygenic effects) was used to estimate the genetic parameters of the studied traits. The same model with the addition of the SNP genotype effect was used for our association analysis. The heritability estimates of CF t and the MCF traits (RCT(eq)=0.258; k(CF)=0.230; CF(max)=0.191; t(max)=0.278) were similar to those obtained using traditional MCPs (0.187 to 0.267), except for the lower estimates for CF(P) (0.064) and k(SR) (0.077). A total of 13 of the 51 tested SNPs had relevant additive effects on at least one trait. We observed associations between MCPs and SNPs in the genes encoding ATP-binding cassette sub-family G member 2 (ABCG2), chemokine ligand 2 (CCL2), growth hormone 1 (GH1), prolactin (PRL) and toll-like receptor 2 (TLR2). Whereas, CF(t) and the MCF traits were associated with polymorphisms in the α-s1-casein (CSN1S1), β-casein (CSN2), GH1, oxidized low-density lipoprotein receptor 1 (OLR1), phospholipase C β1 (PLCB1), PRL and signal transducer and activator of transcription 5A (STAT5A) genes.

  3. Hibiscus rosa- sinensis leaf extract as coagulant aid in leachate treatment

    NASA Astrophysics Data System (ADS)

    Awang, Nik Azimatolakma; Aziz, Hamidi Abdul

    2012-12-01

    Hibiscus rosa- sinensis is a biodegradable material that has remained untested for flocculating properties. The objective of this study is to examine the efficiency of coagulation-flocculation processes for the removal of color, iron (Fe3+), suspended solids, turbidity and ammonia nitrogen(NH3-N), from landfill leachate using 4,000 mg/L alum in conjunction with H. rosa- sinensis leaf extract (HBaqs). Hydroxyl (O-H) and (carboxyl) C=O functional groups along the HBaqs chain help to indulge flocculating efficiency of HBaqs via bridging. The experiments confirm the positive coagulation properties of HBaqs. The Fe3+ removal rate using 4,000 mg/L alum as sole coagulant was approximately 60 %, and increased to 100 % when 4,000 mg/L alum was mixed with 500 mg/L HBaqs. By mixing, 4,000 mg/L alum with 100-500 mg/L HBaqs, 72 % of SS was removed as compared with only 45 % reduction using 4,000 mg/L alum as sole coagulant.

  4. Intrapartum anti-disseminated intravascular coagulation therapy leading to successful vaginal delivery following intrauterine fetal death caused by placental abruption: a case report.

    PubMed

    Honda, Michiko; Matsunaga, Shigetaka; Era, Sumiko; Takai, Yasushi; Baba, Kazunori; Seki, Hiroyuki

    2014-12-23

    Disseminated intravascular coagulation due to placental abruption with intrauterine fetal death is not uncommon. It can result in increased maternal mortality rates and the need for hysterectomy or greater transfusion volumes if the delivery is not completed within six to eight hours. However, consensus is lacking regarding the delivery approach for cases in which delivery is prolonged. A 37-year-old Japanese woman was transported to our tertiary center two and a half hours after the onset of labor because of a diagnosis of placental abruption with intrauterine fetal death at 40 weeks and three days' gestation. On arrival, although severe hypofibrinogenemia was observed, there was no external hemorrhage. Because her cervical canal dilation was good (Bishop score, 7), labor was induced using oxytocin. Anti-disseminated intravascular coagulation therapy was simultaneously started via transfusion. After her hypofibrinogenemia resolved, delivery progressed rapidly, and the fetus was delivered approximately 10 hours after the onset. To reduce postpartum hemorrhage, 6g of fibrinogen concentrate and tranexamic acid, an antifibrinolytic agent, were administered immediately before extraction of the dead fetus and placenta. Although the amount of intrapartum hemorrhage was 1824g, there was no abnormal bleeding after delivery, and our patient was discharged three days later. In cases of placental abruption complicated with disseminated intravascular coagulation, intrapartum administration of coagulation factors can simultaneously promote effective labor and correct hypofibrinogenemia, enabling minimally invasive vaginal delivery.

  5. Effect of high pressures on the enzymatic activity of commercial milk protein coagulants

    NASA Astrophysics Data System (ADS)

    Wiśniewska, Krystyna; Reps, Arnold; Jankowska, Agnieszka

    2014-04-01

    This study was aimed at determining the effect of high pressures in the range of 100-1000 MPa/15 min, applied in 100 MPa increments, on the coagulating and proteolytic activity of commercial coagulants produced with genetic engineering methods: Maxiren, Chymogen, Chymax and of a natural rennin preparation, Hala. The coagulating activity of Hala preparation differed compared with the other preparations, due to greater resistance to high pressures, especially in the range of 500-600 MPa. The preparations produced with genetic engineering methods lost their capability for milk protein coagulation by 500 MPa. Pressurization at 200 MPa contributed to their reduced capability for casein macroproteolysis. In contrast, an increase in Chymax, Chymogen, Maxiren and Hala preparations' hydrolytic capability for the macroproteolysis of isoelectric casein was observed upon pressure treatment at 100 and 400 MPa and for microproteolysis after pressure treatment at 200 MPa. Storage (48 h/5°C) of the pressurized preparations had an insignificant effect on their coagulating and proteolytic activities.

  6. Acute effects of 3G mobile phone radiations on frontal haemodynamics during a cognitive task in teenagers and possible protective value of Om chanting.

    PubMed

    Bhargav, Hemant; N K, Manjunath; Varambally, Shivarama; Mooventhan, A; Bista, Suman; Singh, Deepeshwar; Chhabra, Harleen; Venkatasubramanian, Ganesan; T M, Srinivasan; H R, Nagendra

    2016-06-01

    Mobile phone induced electromagnetic field (MPEMF) as well as chanting of Vedic mantra 'OM' has been shown to affect cognition and brain haemodynamics, but findings are still inconclusive. Twenty right-handed healthy teenagers (eight males and 12 females) in the age range of 18.25 ± 0.44 years were randomly divided into four groups: (1) MPONOM (mobile phone 'ON' followed by 'OM' chanting); (2) MPOFOM (mobile phone 'OFF' followed by 'OM' chanting); (3) MPONSS (mobile phone 'ON' followed by 'SS' chanting); and (4) MPOFSS (mobile phone 'OFF' followed by 'SS' chanting). Brain haemodynamics during Stroop task were recorded using a 64-channel fNIRS device at three points of time: (1) baseline, (2) after 30 min of MPON/OF exposure, and (3) after 5 min of OM/SS chanting. RM-ANOVA was applied to perform within- and between-group comparisons, respectively. Between-group analysis revealed that total scores on incongruent Stroop task were significantly better after OM as compared to SS chanting (MPOFOM vs MPOFSS), pre-frontal activation was significantly lesser after OM as compared to SS chanting in channel 13. There was no significant difference between MPON and MPOF conditions for Stroop performance, as well as brain haemodynamics. These findings need confirmation through a larger trial in future.

  7. Enhanced coagulation for turbidity and Total Organic Carbon (TOC) removal from river Kansawati water.

    PubMed

    Narayan, Sumit; Goel, Sudha

    2011-01-01

    The objective of this study was to determine optimum coagulant doses for turbidity and Total Organic Carbon (TOC) removal and evaluate the extent to which TOC can be removed by enhanced coagulation. Jar tests were conducted in the laboratory to determine optimum doses of alum for the removal of turbidity and Natural Organic Matter (NOM) from river water. Various other water quality parameters were measured before and after thejar tests and included: UV Absorbance (UVA) at 254 nm, microbial concentrations, TDS, conductivity, hardness, alkalinity, and pH. The optimum alum dose for removal of turbidity and TOC was 20 mg/L for the sample collected in November 2009 and 100 mg/L for the sample collected in March 2010. In both cases, the dose for enhanced coagulation was significantly higher than that for conventional coagulation. The gain in TOC removal was insignificant compared to the increase in coagulant dose required. This is usual for low TOC (< 2 mg/L)--high alkalinity water. Other water samples with higher TOC need to be tested to demonstrate the effectiveness of enhanced coagulation.

  8. Effect of platelet-derived β-thromboglobulins on coagulation.

    PubMed

    Egan, Karl; van Geffen, Johanna P; Ma, Hui; Kevane, Barry; Lennon, Aine; Allen, Seamus; Neary, Elaine; Parsons, Martin; Maguire, Patricia; Wynne, Kieran; O' Kennedy, Richard; Heemskerk, Johan W M; Áinle, Fionnuala Ní

    2017-06-01

    β-thromboglobulins are derived from the cleavage of the CXC chemokine platelet basic protein and are released in high concentrations by activated platelets. Platelet-derived β-thromboglobulins (βTG) share 70% homology with platelet factor 4 (PF4), another CXC chemokine released by activated platelets. PF4 modulates coagulation by inhibiting heparin-antithrombin interactions, promoting protein C activation, and attenuating the activity of activated protein C. In contrast, the effect of βTG on coagulation is unknown. Clotting times, thrombin generation, chromogenic clotting factor assays, and surface plasmon resonance (SPR) were used to assess the effect of purified βTG on coagulation. In normal pooled plasma, βTG shortened the lagtime and time to peak thrombin generation of tissue factor (TF)-dependent and TF-independent thrombin generation. In factor VIII and factor IX-deficient plasmas, βTG induced thrombin generation in the absence of a TF stimulus and in the presence of anti-TF and factor VIIa inhibitory antibodies. The procoagulant effect was not observed when thrombin generation was independent of factor X activation (supplementation of factor X-deficient plasma with factor Xa). Cleavage of a factor Xa-specific chromogenic substrate was observed when βTG was incubated with factor X, suggesting a direct interaction between βTG and factor X. Using SPR, βTG were found to bind to immobilised factor X in a dose dependent manner. βTG modulate coagulation in vitro via an interaction with factor X. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Hi-tech of the prostate: interstitial laser coagulation of benign prostatic hypertrophy

    NASA Astrophysics Data System (ADS)

    Muschter, Rolf; Hofstetter, Alfons G.; Hessel, Stefan F. F.; Keiditsch, Ernst; Rothenberger, Karl-Heinz; Schneede, Peter; Frank, Klaus H.

    1992-06-01

    We report on the new technique of interstitial laser coagulation of the prostate (ILCP) in the treatment of benign prostatic hyperplasia (BPH). Basic experiments by use of a Nd:YAG laser in combination with a newly designed fiber tip homogeneously distributing the laser irradiation have been performed in potato, muscle, liver, and surgically removed human BPH-tissue to determine the volume of coagulation. The coagulation zone surrounding the probe was well defined and homogeneous. The size was dependent on laser power and irradiation time. Carbonization was never present except in darker tissues irradiated with high energy. Volume and time resolved measurements correlated well with the size of coagulation. 10 W and 5 minutes, for example, resulted in a coagulation zone of 17 X 15 mm. Comparable results have been seen in in-vivo experiments in surgically exposed canine prostates. Specimen for macroscopic and microscopic examination were taken immediately after treatment and after 5 and 35 days. The well demarked coagulation necrosis of the early stage resulted in cystic degeneration and fibrosis in the later stages. This was combined with shrinkage and reduction in volume. The urothelium of the urethra, the external sphincter and the rectum showed no damage. Until now, 15 patients suffering from obstructive symptoms due to BPH have been treated with interstitial laser coagulation. The probes were inserted from the perineum into the center of each lateral lobe of the prostate by transrectal ultrasound guidance, while the median lobe was treated by urethroscopic guidance, while the median lobe was treated by urethroscopic control. Dependent on the size of the prostate irradiation, time was 5 to 10 minutes per lobe at a power setting of 5 to 10 W.

  10. Effects of preemptive analgesia with parecoxib sodium on haemodynamics and plasma stress hormones in surgical patients with thyroid carcinoma.

    PubMed

    Wang, Lian-Dong; Gao, Xia; Li, Jun-Ying; Yu, Hong-Yan; Su, Hai-Wen; Liu, Lian-Zhong; Qi, Jun

    2015-01-01

    To investigate the effects of preemptive analgesia with parecoxib sodium on haemodynamics and plasma stress hormones in surgical patients with thyroid carcinoma. Fifty-seven patients with thyroid carcinoma who underwent thyroidectomy selectively in Laiwu Hospital Affiliated to Taishan Medical University and Binzhou People's Hospital were selected and randomly divided into three groups, 19 cases in each group. The control group was intravenously injected 0.9% sodium chloride injection before anesthesia induction; trial group I was intravenously injected with parecoxib sodium 20 min before anesthesia induction; based on trial group I, trial group II was injected with parecoxib sodium again 12 h after surgery. The levels of plasma norepinephrine (NE), cortisol (Cor) and blood glucose before, 12 and 24 h after surgery and changes of haemodynamics before surgery, at the end of surgery and 12, 24 and 48 h after surgery were compared in the three groups. Besides, visual analogue scale (VAS) scores were recorded 4, 8, 12 and 24 h after surgery. 12 and 24 h after surgery, the levels of plasma NE and Cor in three groups rose dramatically (P<0.05 or (P<0.01); The levels of plasma NE and Cor in trial groups I and II were evidently lower than in control group (P<0.05 or P<0.01), and those in trial group II slightly lower than in trial group I. 12 h after surgery, the heart rates (HR) and systolic pressures (SBP) in trial groups I and II increased obviously by comparison to surgery before (P<0.05 or P<0.01), but gradually returned to the preoperative level. HR, SBP and diastolic pressures (DBP) in trial groups I and II at the end of surgery and 12 h after surgery were all lower than in the control group, and significant differences were present (P<0.05 or (P<0.01). At 4, 8, 12 and 24 h after surgery, VAS scores in trial groups I and II were markedly lower than in the control group ((P<0.05 or (P<0.01), the scores in trial group II being the lowest. Combined application of

  11. Critical assessment of chitosan as coagulant to remove cyanobacteria.

    PubMed

    Lürling, Miquel; Noyma, Natalia Pessoa; de Magalhães, Leonardo; Miranda, Marcela; Mucci, Maíra; van Oosterhout, Frank; Huszar, Vera L M; Marinho, Marcelo Manzi

    2017-06-01

    Removal of cyanobacteria from the water column using a coagulant and a ballast compound is a promising technique to mitigate nuisance. As coagulant the organic, biodegradable polymer chitosan has been promoted. Results in this study show that elevated pH, as may be common during cyanobacterial blooms, as well as high alkalinity may hamper the coagulation of chitosan and thus impair its ability to effectively remove positively buoyant cyanobacteria from the water column. The underlying mechanism is likely a shielding of the protonated groups by anions. Inasmuch as there are many chitosan formulations, thorough testing of each chitosan prior to its application is essential. Results obtained in glass tubes were similar to those from standard jar tests demonstrating that glass tube tests can be used for testing effects of coagulants and ballasts in cyanobacteria removal whilst allowing far more replicates. There was no relation between zeta potential and precipitated cyanobacteria. Given the well-known antibacterial activity of chitosan and recent findings of anti-cyanobacterial effects, pre-application tests are needed to decipher if chitosan may cause cell leakage of cyanotoxins. Efficiency- and side-effect testing are crucial for water managers to determine if the selected approach can be used in tailor-made interventions to control cyanobacterial blooms and to mitigate eutrophication. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Comparison of single-step and two-step purified coagulants from Moringa oleifera seed for turbidity and DOC removal.

    PubMed

    Sánchez-Martín, J; Ghebremichael, K; Beltrán-Heredia, J

    2010-08-01

    The coagulant proteins from Moringa oleifera purified with single-step and two-step ion-exchange processes were used for the coagulation of surface water from Meuse river in The Netherlands. The performances of the two purified coagulants and the crude extract were assessed in terms of turbidity and DOC removal. The results indicated that the optimum dosage of the single-step purified coagulant was more than two times higher compared to the two-step purified coagulant in terms of turbidity removal. And the residual DOC in the two-step purified coagulant was lower than in single-step purified coagulant or crude extract. (c) 2010 Elsevier Ltd. All rights reserved.

  13. Performance of alum and assorted coagulants in turbidity removal of muddy water

    NASA Astrophysics Data System (ADS)

    Malik, Qasim H.

    2018-03-01

    Coagulation is a primary and cost effective process in water treatment plants. Under optimum conditions, not only it effectively removes turbidity but also results in reduced sludge volume and subsequently minimizes sludge management costs. Highly turbid water from streams, canals, rivers and rain run offs was run through jar test for turbidity removal. The brown water with 250NTU turbidity when coagulated with alum and assorted coagulants proved that maximum turbidity removal was witnessed using alum dose of 0.25 g/l at ph 6 with a sedimentation time of 30 min.

  14. Biomarkers of inflammation, coagulation and microbial translocation in HIV/HCV co-infected patients in the SMART study.

    PubMed

    Peters, Lars; Neuhaus, Jacqueline; Duprez, Daniel; Neaton, James D; Tracy, Russel; Klein, Marina B; Mocroft, Amanda; Rockstroh, Jürgen; Dore, Gregory; Lundgren, Jens D

    2014-07-01

    Previous results from the SMART study showed that HIV/viral hepatitis co-infected persons with impaired liver function are at increased risk of death following interruption of antiretroviral therapy (ART). To investigate the influence of fibrosis and ART interruption on levels of biomarkers of inflammation, coagulation and microbial translocation in HIV/HCV co-infected persons in the SMART study. All HIV/HCV co-infected persons with stored plasma at study entry and at six months of follow-up were included (N=362). D-dimer, IL-6, sCD14 and hepatic synthesized coagulation markers were measured and compared according to the liver fibrosis marker hyaluronic acid (HA) at study entry. Percent difference in changes in biomarker levels from study entry to month 6 was compared between randomization groups and according to study entry HA levels. At study entry, persons with elevated HA (>75ng/mL vs. ≤75ng/mL) had higher median (IQR) levels of IL-6 [4.14pg/mL (2.60-6.32) vs. 2.74pg/mL (1.88-3.97)] and soluble CD14 [2163ng/mL (1952-2916) vs. 1979ng/mL (1742-2310)] (p<0.001). Elevated HA was also associated with alterations of both pro- and anti-coagulation markers but the overall coagulation profile was not affected. Interruption of ART lead to a particularly pronounced increase in IL-6 levels in persons with elevated HA levels (p=0.01 for interaction between randomization group and continuous HA level). HIV/HCV co-infected persons with impaired liver function are in an enhanced pro-inflammatory state which is further exacerbated upon interruption of ART. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Matriptase activation connects tissue factor-dependent coagulation initiation to epithelial proteolysis and signaling.

    PubMed

    Le Gall, Sylvain M; Szabo, Roman; Lee, Melody; Kirchhofer, Daniel; Craik, Charles S; Bugge, Thomas H; Camerer, Eric

    2016-06-23

    The coagulation cascade is designed to sense tissue injury by physical separation of the membrane-anchored cofactor tissue factor (TF) from inactive precursors of coagulation proteases circulating in plasma. Once TF on epithelial and other extravascular cells is exposed to plasma, sequential activation of coagulation proteases coordinates hemostasis and contributes to host defense and tissue repair. Membrane-anchored serine proteases (MASPs) play critical roles in the development and homeostasis of epithelial barrier tissues; how MASPs are activated in mature epithelia is unknown. We here report that proteases of the extrinsic pathway of blood coagulation transactivate the MASP matriptase, thus connecting coagulation initiation to epithelial proteolysis and signaling. Exposure of TF-expressing cells to factors (F) VIIa and Xa triggered the conversion of latent pro-matriptase to an active protease, which in turn cleaved the pericellular substrates protease-activated receptor-2 (PAR2) and pro-urokinase. An activation pathway-selective PAR2 mutant resistant to direct cleavage by TF:FVIIa and FXa was activated by these proteases when cells co-expressed pro-matriptase, and matriptase transactivation was necessary for efficient cleavage and activation of wild-type PAR2 by physiological concentrations of TF:FVIIa and FXa. The coagulation initiation complex induced rapid and prolonged enhancement of the barrier function of epithelial monolayers that was dependent on matriptase transactivation and PAR2 signaling. These observations suggest that the coagulation cascade engages matriptase to help coordinate epithelial defense and repair programs after injury or infection, and that matriptase may contribute to TF-driven pathogenesis in cancer and inflammation.

  16. An assessment of thromboelastometry to monitor blood coagulation and guide transfusion support in liver transplantation.

    PubMed

    Blasi, Annabel; Beltran, Joan; Pereira, Arturo; Martinez-Palli, Graciela; Torrents, Abiguei; Balust, Jaume; Zavala, Elizabeth; Taura, Pilar; Garcia-Valdecasas, Juan-Carlos

    2012-09-01

    Rotation thromboelastometry (TEM) has been proposed as a convenient alternative to standard coagulation tests in guiding the treatment of coagulopathy during orthotopic liver transplantation (OLT). This study was aimed at assessing the value of TEM in monitoring blood coagulation and guide transfusion support in OLT. Standard coagulation and TEM (EXTEM and FIBTEM) tests were performed at four preestablished intraoperative time points in 236 OLTs and prospectively recorded in a dedicated database together with the main operative and transfusion data. Transfusion thresholds were based on standard coagulation tests. Spearman's rank correlation (ρ), linear regression, and receiver operating characteristic curves were used when appropriate. EXTEM maximum clot firmness (MCF(EXTEM)) was the TEM variable that best correlated with the platelet (PLT) and fibrinogen levels (ρ = 0.62 and ρ = 0.69, respectively). MCF(FIBTEM) correlated with fibrinogen level (ρ = 0.70). EXTEM clot amplitude at 10 minutes (A10(EXTEM)) was a good linear predictor of MCF(EXTEM) (R(2) =0.93). The cutoff values that best predicted the transfusion threshold for PLTs and fibrinogen were A10(EXTEM) = 35 mm and A10(FIBTEM) = 8 mm. At these values, the negative and positive predictive accuracies of TEM to predict the transfusion thresholds were 95 and 27%, respectively. A10(EXTEM) is an adequate TEM variable to guide therapeutic decisions during OLT. Patients with A10(EXTEM) of greater than 35 mm are unlikely to bleed because of coagulation deficiencies, but using A10(EXTEM) of not more than 35 mm as the sole transfusion criterion can lead to unnecessary utilization of PLTs and fibrinogen-rich products. © 2012 American Association of Blood Banks.

  17. Host defense peptides of thrombin modulate inflammation and coagulation in endotoxin-mediated shock and Pseudomonas aeruginosa sepsis.

    PubMed

    Kalle, Martina; Papareddy, Praveen; Kasetty, Gopinath; Mörgelin, Matthias; van der Plas, Mariena J A; Rydengård, Victoria; Malmsten, Martin; Albiger, Barbara; Schmidtchen, Artur

    2012-01-01

    Gram-negative sepsis is accompanied by a disproportionate innate immune response and excessive coagulation mainly induced by endotoxins released from bacteria. Due to rising antibiotic resistance and current lack of other effective treatments there is an urgent need for new therapies. We here present a new treatment concept for sepsis and endotoxin-mediated shock, based on host defense peptides from the C-terminal part of human thrombin, found to have a broad and inhibitory effect on multiple sepsis pathologies. Thus, the peptides abrogate pro-inflammatory cytokine responses to endotoxin in vitro and in vivo. Furthermore, they interfere with coagulation by modulating contact activation and tissue factor-mediated clotting in vitro, leading to normalization of coagulation responses in vivo, a previously unknown function of host defense peptides. In a mouse model of Pseudomonas aeruginosa sepsis, the peptide GKY25, while mediating a modest antimicrobial effect, significantly inhibited the pro-inflammatory response, decreased fibrin deposition and leakage in the lungs, as well as reduced mortality. Taken together, the capacity of such thrombin-derived peptides to simultaneously modulate bacterial levels, pro-inflammatory responses, and coagulation, renders them attractive therapeutic candidates for the treatment of invasive infections and sepsis.

  18. Relationship between exercise pressure gradient and haemodynamic progression of aortic stenosis.

    PubMed

    Ringle, Anne; Levy, Franck; Ennezat, Pierre-Vladimir; Le Goffic, Caroline; Castel, Anne-Laure; Delelis, François; Menet, Aymeric; Malaquin, Dorothée; Graux, Pierre; Vincentelli, André; Tribouilloy, Christophe; Maréchaux, Sylvestre

    We hypothesized that large exercise-induced increases in aortic mean pressure gradient can predict haemodynamic progression during follow-up in asymptomatic patients with aortic stenosis. We retrospectively identified patients with asymptomatic moderate or severe aortic stenosis (aortic valve area<1.5cm 2 or<1cm 2 ) and normal ejection fraction, who underwent an exercise stress echocardiography at baseline with a normal exercise test and a resting echocardiography during follow-up. The relationship between exercise-induced increase in aortic mean pressure gradient and annualised changes in resting mean pressure gradient during follow-up was investigated. Fifty-five patients (mean age 66±15 years; 45% severe aortic stenosis) were included. Aortic mean pressure gradient significantly increased from rest to peak exercise (P<0.001). During a median follow-up of 1.6 [1.1-3.2] years, resting mean pressure gradient increased from 35±13mmHg to 48±16mmHg, P<0.0001. Median annualised change in resting mean pressure gradient during follow-up was 5 [2-11] mmHg. Exercise-induced increase in aortic mean pressure gradient did correlate with annualised changes in mean pressure gradient during follow-up (r=0.35, P=0.01). Hemodynamic progression of aortic stenosis was faster in patients with large exercise-induced increase in aortic mean pressure gradient (≥20mmHg) as compared to those with exercise-induced increase in aortic mean pressure gradient<20mmHg (median annualised increase in mean pressure gradient 19 [6-28] vs. 4 [2-10] mmHg/y respectively, P=0.002). Similar results were found in the subgroup of 30 patients with moderate aortic stenosis. Large exercise-induced increases in aortic mean pressure gradient correlate with haemodynamic progression of stenosis during follow-up in patients with asymptomatic aortic stenosis. Further studies are needed to fully establish the role of ESE in the decision-making process in comparison to other prognostic markers in asymptomatic

  19. Economic aspects of intraoperative coagulation management targeting higher fibrinogen concentrations during major craniosynostosis surgery.

    PubMed

    Haas, Thorsten; Spielmann, Nelly; Restin, Tanja; Schmidt, Alexander R; Schmugge, Markus; Cushing, Melissa M

    2016-01-01

    Results of a previously published study demonstrated a significant decrease in transfusion requirements and calculated blood loss for pediatric major craniosynostosis surgery, if a ROTEM(®) FIBTEM trigger of <13 mm (early substitution group) was applied as compared to a trigger of <8 mm (conventional group). The aim of this study was a posthoc analysis of the costs for this coagulation management. The total volume as well as the number of units or bags for all transfused blood products and coagulation factors were recorded for each case. The number of laboratory and point-of-care coagulation tests was also analyzed. Total blood product costs were calculated according to the local prices per unit. The total cost for all transfused/administered blood products/coagulation factors per patient was a median of 1023EUR (IQR 850EUR-1058EUR) in the early substitution group as compared to a median of 910EUR (IQR 719EUR-1351EUR) in the conventional group (P = 0.81). No difference in the number of coagulation tests performed was observed. In this study, the use of a higher fibrinogen trigger was not linked to a significant increase in total costs for transfused blood products and coagulation factors, and may offer an economically equivalent approach to coagulation management. © 2015 John Wiley & Sons Ltd.

  20. Chest shielding for prevention of a haemodynamically significant patent ductus arteriosus in preterm infants receiving phototherapy.

    PubMed

    Bhola, Kavita; Foster, Jann P; Osborn, David A

    2015-11-03

    Patent ductus arteriosus (PDA) is associated with mortality and morbidity in preterm infants. Phototherapy is a common treatment for jaundice in preterm infants. However, phototherapy has been associated with failure of closure of the ductus arteriosus in preterm infants. To determine if chest shielding of preterm infants receiving phototherapy reduces the incidence of clinically and/or haemodynamically significant PDA and reduces morbidity secondary to PDA. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library; 2015, Issue 3), MEDLINE, EMBASE, CINAHL, previous reviews, cross-references, abstracts, proceedings of scientific meetings, and trial registries through March 2015. Randomised controlled trials (RCTs), cluster-RCTs, or quasi-RCTs of chest shielding during phototherapy compared to sham shielding or no shielding for the prevention of a haemodynamically or clinically significant PDA in preterm infants. Three review authors independently assessed studies for eligibility and quality and extracted data. We defined a clinically significant PDA as the presence of a PDA with clinical signs of an effect on organ function attributable to the ductus arteriosus. We defined a haemodynamically significant PDA as clinical and/or echocardiographic signs of a significant ductus arteriosus effect on blood flow. We included two small trials enrolling very preterm infants (Rosenfeld 1986; Travadi 2006). We assessed both as at high risk of bias. No study reported clinically significant PDA, defined as the presence of a PDA with clinical symptoms or signs attributable to the effect of a ductus arteriosus on organ function. Rosenfeld 1986 reported a non-significant reduction in haemodynamically significant PDA with left atrial to aortic root ratio greater than 1.2 (risk ratio (RR) 0.23, 95% confidence interval (CI) 0.05 to 1.01; 74 infants) but a statistically significant risk difference (RD -0.18, 95% CI -0.34 to -0.03; number needed to

  1. Multifrequency acoustics as a probe of mesoscopic blood coagulation dynamics

    NASA Astrophysics Data System (ADS)

    Ganesan, Adarsh; Rajendran, Gokulnath; Ercole, Ari; Seshia, Ashwin

    2016-08-01

    Coagulation is a complex enzymatic polymerisation cascade. Disordered coagulation is common in medicine and may be life-threatening yet clinical assays are typically bulky and/or provide an incomplete picture of clot mechanical evolution. We present the adaptation of an in-plane acoustic wave device: quartz crystal microbalance with dissipation at multiple harmonics to determine the time-evolution of mesoscale mechanical properties of clot formation in vitro. This approach is sensitive to changes in surface and bulk clot structure in various models of induced coagulopathy. Furthermore, we are able to show that clot formation at surfaces has different kinetics and mechanical strength to that in the bulk, which may have implications for the design of bioprosthetic materials. The "Multifrequency acoustics" approach thus enables unique capability to portray biological processes concerning blood coagulation.

  2. Moringa oleifera-mediated coagulation of textile wastewater and its biodegradation using novel consortium-BBA grown on agricultural waste substratum.

    PubMed

    Bedekar, Priyanka A; Bhalkar, Bhumika N; Patil, Swapnil M; Govindwar, Sanjay P

    2016-10-01

    Generation of secondary sludge is a major concern of textile dye removal by coagulation process. Combinatorial coagulation-biodegradation treatment system has been found efficient in degradation of coagulated textile dye sludge. Moringa oleifera seed powder (700 mg L -1 ) was able to coagulate textile dyestuff from real textile wastewater with 98 % color removal. Novel consortium-BBA was found to decolorize coagulated dye sludge. Parameters that significantly affect coagulation process were optimized using response surface methodology. The bench-scale stirred tank reactor (50-L capacity) designed with optimized parameters for coagulation process could efficiently remove 98, 89, 78, and 67 % of American Dye Manufacturer's Institute (ADMI) in four repetitive cycles, respectively. Solid-state fermentation composting reactor designed to treat coagulated dye sludge showed 96 % removal of dye within 10 days. Coagulation of dyes from textile wastewater and degradation of coagulated dye sludge were confirmed by Fourier transform infrared spectroscopy (FTIR) analysis. Cell morphology assay, comet assay, and phytotoxicity confirmed the formation of less toxic products after coagulation and degradation mechanism.

  3. The effects of chemical coagulants on the decolorization of dyes by electrocoagulation using response surface methodology (RSM)

    NASA Astrophysics Data System (ADS)

    Butler, Erick B.; Hung, Yung-Tse; Mulamba, Oliver

    2017-09-01

    This study assessed the efficiency of electrocoagulation (ECF) coupled with an addition of chemical coagulant to decolorize textile dye. Tests were conducted using Box Behnken methodology to vary six parameters: dye type, weight, coagulant type, dose, initial pH and current density. The combination of electrocoagulation and chemical coagulation was able to decolorize dye up to 99.42 % in 30 min of treatment time which is remarkably shorter in comparison with using conventional chemical coagulation. High color removal was found to be contingent upon the dye type and current density, along with the interactions between the current density and the coagulant dose. The addition of chemical coagulants did enhanced treatment efficiency.

  4. Manufacture of small calibre quadruple lamina vascular bypass grafts using a novel automated extrusion-phase-inversion method and nanocomposite polymer.

    PubMed

    Sarkar, Sandip; Burriesci, Gaetano; Wojcik, Adam; Aresti, Nicholas; Hamilton, George; Seifalian, Alexander M

    2009-04-16

    Long-term patency of expanded polytetrafluoroethylene (ePTFE) small calibre cardiovascular bypass prostheses (<6mm) is poor because of thrombosis and intimal hyperplasia due to low compliance, stimulating the search for elastic alternatives. Wall porosity allows effective post-implantation graft healing, encouraging endothelialisation and a measured fibrovascular response. We have developed a novel poly (carbonate) urethane-based nanocomposite polymer incorporating polyhedral oligomeric silsesquioxane (POSS) nanocages (UCL-NANO) which shows anti-thrombogenicity and biostability. We report an extrusion-phase-inversion technique for manufacturing uniform-walled porous conduits using UCL-NANO. Image analysis-aided wall measurement showed that two uniform wall-thicknesses could be specified. Different coagulant conditions revealed the importance of low-temperature phase-inversion for graft integrity. Although minor reduction of pore-size variation resulted from the addition of ethanol or N,N-dimethylacetamide, high concentrations of ethanol as coagulant did not provide uniform porosity throughout the wall. Tensile testing showed the grafts to be elastic with strength being directly proportional to weight. The ultimate strengths achieved were above those expected from haemodynamic conditions, with anisotropy due to the manufacturing process. Elemental analysis by energy-dispersive X-ray analysis did not show a regional variation of POSS on the lumen or outer surface. In conclusion, the automated vertical extrusion-phase-inversion device can reproducibly fabricate uniform-walled small calibre conduits from UCL-NANO. These elastic microporous grafts demonstrate favourable mechanical integrity for haemodynamic exposure and are currently undergoing in-vivo evaluation of durability and healing properties.

  5. Chronic sleep deprivation markedly reduces coagulation factor VII expression

    PubMed Central

    Pinotti, Mirko; Bertolucci, Cristiano; Frigato, Elena; Branchini, Alessio; Cavallari, Nicola; Baba, Kenkichi; Contreras-Alcantara, Susana; Ehlen, J. Christopher; Bernardi, Francesco; Paul, Ketema N.; Tosini, Gianluca

    2010-01-01

    Chronic sleep loss, a common feature of human life in industrialized countries, is associated to cardiovascular disorders. Variations in functional parameters of coagulation might contribute to explain this relationship. By exploiting the mouse model and a specifically designed protocol, we demonstrated that seven days of partial sleep deprivation significantly decreases (−30.5%) the thrombin generation potential in plasma evaluated upon extrinsic (TF/FVIIa pathway) but not intrinsic activation of coagulation. This variation was consistent with a decrease (−49.8%) in the plasma activity levels of factor VII (FVII), the crucial physiologicalal trigger of coagulation, which was even more pronounced at the liver mRNA level (−85.7%). The recovery in normal sleep conditions for three days completely restored thrombin generation and FVII activity in plasma. For the first time, we demonstrate that chronic sleep deprivation on its own reduces, in a reversible manner, the FVII expression levels, thus influencing the TF/FVIIa activation pathway efficiency. PMID:20418241

  6. Accelerating population balance-Monte Carlo simulation for coagulation dynamics from the Markov jump model, stochastic algorithm and GPU parallel computing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Zuwei; Zhao, Haibo, E-mail: klinsmannzhb@163.com; Zheng, Chuguang

    2015-01-15

    This paper proposes a comprehensive framework for accelerating population balance-Monte Carlo (PBMC) simulation of particle coagulation dynamics. By combining Markov jump model, weighted majorant kernel and GPU (graphics processing unit) parallel computing, a significant gain in computational efficiency is achieved. The Markov jump model constructs a coagulation-rule matrix of differentially-weighted simulation particles, so as to capture the time evolution of particle size distribution with low statistical noise over the full size range and as far as possible to reduce the number of time loopings. Here three coagulation rules are highlighted and it is found that constructing appropriate coagulation rule providesmore » a route to attain the compromise between accuracy and cost of PBMC methods. Further, in order to avoid double looping over all simulation particles when considering the two-particle events (typically, particle coagulation), the weighted majorant kernel is introduced to estimate the maximum coagulation rates being used for acceptance–rejection processes by single-looping over all particles, and meanwhile the mean time-step of coagulation event is estimated by summing the coagulation kernels of rejected and accepted particle pairs. The computational load of these fast differentially-weighted PBMC simulations (based on the Markov jump model) is reduced greatly to be proportional to the number of simulation particles in a zero-dimensional system (single cell). Finally, for a spatially inhomogeneous multi-dimensional (multi-cell) simulation, the proposed fast PBMC is performed in each cell, and multiple cells are parallel processed by multi-cores on a GPU that can implement the massively threaded data-parallel tasks to obtain remarkable speedup ratio (comparing with CPU computation, the speedup ratio of GPU parallel computing is as high as 200 in a case of 100 cells with 10 000 simulation particles per cell). These accelerating approaches of PBMC

  7. On the acid-base properties of humic acid in soil.

    PubMed

    Cooke, James D; Hamilton-Taylor, John; Tipping, Edward

    2007-01-15

    Humic acid was isolated from three contrasting organic-rich soils and acid-base titrations performed over a range of ionic strengths. Results obtained were unlike most humic acid data sets; they showed a greater ionic strength dependency at low pH than at high pH. Forward- and back-titrations with the base and acid revealed hysteresis, particularly at low pH. Previous authors attributed this type of hysteresis to humic acid aggregates-created during the isolation procedure-being redissolved during titration as the pH increased and regarded the results as artificial. However, forward- and back-titrations with organic-rich soils also demonstrated a similar hysteretic behavior. These observations indicate (i) that titrations of humic acid in aggregated form (as opposed to the more usual dissolved form) are more representative of the acid-base properties of humic acid in soil and (ii) that the ionic strength dependency of proton binding in humic acid is related to its degree of aggregation. Thus, the current use of models based on data from dissolved humic substances to predictthe acid-base properties of humic acid in soil under environmental conditions may be flawed and could substantially overestimate their acid buffering capacity.

  8. Effects of nitric oxide synthase inhibition with or without cyclooxygenase-2 inhibition on resting haemodynamics and responses to exendin-4

    PubMed Central

    Gardiner, S M; March, J E; Kemp, P A; Bennett, T

    2006-01-01

    Background and purpose: Interactions between the NO system and the cyclooxygenase systems may be important in cardiovascular regulation. Here we measured the effects of acute cyclooxygenase-2 inhibition (with parecoxib), alone and in combination with NOS inhibition (with N G-nitro-L-arginine methyl ester (L-NAME)), on resting cardiovascular variables and on responses to the glucagon-like peptide 1 agonist, exendin-4, which causes regionally-selective vasoconstriction and vasodilatation. Experimental approach: Rats were instrumented with flow probes and intravascular catheters to measure regional haemodynamics in the conscious, freely moving state. L-NAME was administered as a primed infusion 180 min after administration of parecoxib or vehicle, and exendin-4 was given 60 min after the onset of L-NAME infusion. Key results: Parecoxib had no effect on resting cardiovascular variables or on responses to L-NAME. Exendin-4 caused a pressor response accompanied by tachycardia, mesenteric vasoconstriction and hindquarters vasodilatation. Parecoxib did not affect haemodynamic responses to exendin-4, but L-NAME inhibited its hindquarters vasodilator and tachycardic effects. When combined, L-NAME and parecoxib almost abolished the hindquarters vasodilatation while enhancing the pressor response. Conclusions and implications: Cyclooxygenase-2-derived products do not affect basal haemodynamic status in conscious normotensive rats, or influence the NO system acutely. The inhibitory effects of L-NAME on the hindquarters vasodilator and tachycardic effects of exendin-4 are consistent with a previous study that showed those events to be β-adrenoceptor mediated. The additional effect of parecoxib on responses to exendin-4 in the presence of L-NAME, is consistent with other evidence for enhanced involvement of vasodilator prostanoids when NO production is reduced. PMID:17016494

  9. Dynamic and quantitative assessment of blood coagulation using optical coherence elastography

    PubMed Central

    Xu, Xiangqun; Zhu, Jiang; Chen, Zhongping

    2016-01-01

    Reliable clot diagnostic systems are needed for directing treatment in a broad spectrum of cardiovascular diseases and coagulopathy. Here, we report on non-contact measurement of elastic modulus for dynamic and quantitative assessment of whole blood coagulation using acoustic radiation force orthogonal excitation optical coherence elastography (ARFOE-OCE). In this system, acoustic radiation force (ARF) is produced by a remote ultrasonic transducer, and a shear wave induced by ARF excitation is detected by the optical coherence tomography (OCT) system. During porcine whole blood coagulation, changes in the elastic property of the clots increase the shear modulus of the sample, altering the propagating velocity of the shear wave. Consequently, dynamic blood coagulation status can be measured quantitatively by relating the velocity of the shear wave with clinically relevant coagulation metrics, including reaction time, clot formation kinetics and maximum shear modulus. The results show that the ARFOE-OCE is sensitive to the clot formation kinetics and can differentiate the elastic properties of the recalcified porcine whole blood, blood added with kaolin as an activator, and blood spiked with fibrinogen. PMID:27090437

  10. Dynamic and quantitative assessment of blood coagulation using optical coherence elastography

    NASA Astrophysics Data System (ADS)

    Xu, Xiangqun; Zhu, Jiang; Chen, Zhongping

    2016-04-01

    Reliable clot diagnostic systems are needed for directing treatment in a broad spectrum of cardiovascular diseases and coagulopathy. Here, we report on non-contact measurement of elastic modulus for dynamic and quantitative assessment of whole blood coagulation using acoustic radiation force orthogonal excitation optical coherence elastography (ARFOE-OCE). In this system, acoustic radiation force (ARF) is produced by a remote ultrasonic transducer, and a shear wave induced by ARF excitation is detected by the optical coherence tomography (OCT) system. During porcine whole blood coagulation, changes in the elastic property of the clots increase the shear modulus of the sample, altering the propagating velocity of the shear wave. Consequently, dynamic blood coagulation status can be measured quantitatively by relating the velocity of the shear wave with clinically relevant coagulation metrics, including reaction time, clot formation kinetics and maximum shear modulus. The results show that the ARFOE-OCE is sensitive to the clot formation kinetics and can differentiate the elastic properties of the recalcified porcine whole blood, blood added with kaolin as an activator, and blood spiked with fibrinogen.

  11. As(III) oxidation by active chlorine and subsequent removal of As(V) by Al13 polymer coagulation using a novel dual function reagent.

    PubMed

    Hu, Chengzhi; Liu, Huijuan; Chen, Guixia; Jefferson, William A; Qu, Jiuhui

    2012-06-19

    An electrochemically prepared water treatment reagent containing a high concentration of Al(13) polymer and active chlorine (PACC) showed promising potential for the removal of As(III) due to the combined function of oxidation and coagulation. The results indicated that PACC was effective for As(III) removal through oxidation by the active chlorine and subsequent removal of As(V) by coagulation with the Al(13) polymer. The As(III) was oxidized to As(V) by active chlorine in PACC, with a stoichiometric rate of 0.99 mg Cl(2)/mg As(III). The Al(13) polymer was the most active Al species responsible for As(V) removal in PACC. To meet As drinking water standards the stoichiometric weight ratio of Cl(2)/Al within PACC was 0.09 for the treatment of As(III). Considering the process of As(III) oxidation and As(V) coagulation together, the optimal pH conditions for the removal of As by PACC was within the neutral range, which facilitated the reaction of As(III) with active chlorine and favored the formation of Al hydroxide flocs. The presence of humic acid reduced the As(III) removal efficiency of PACC due to its negative influence on subsequent As(V) coagulation, and disinfection byproduct yields were very low in the presence of insufficient or stoichiometric active chlorine.

  12. A novel suction/coagulation integrated probe for achieving better hemostasis: development and clinical use.

    PubMed

    Takahashi, Hidekazu; Haraguchi, Naotsugu; Nishimura, Junichi; Hata, Taishi; Matsuda, Chu; Yamamoto, Hirofumi; Mizushima, Tsunekazu; Mori, Masaki; Doki, Yuichiro; Nakajima, Kiyokazu

    2018-06-01

    Modern electrosurgical tools have a specific coagulation mode called "soft coagulation". However, soft coagulation has not been widely accepted for surgical operations. To optimize the soft coagulation environment, we developed a novel suction device integrated with an electrosurgical probe, called the "Suction ball coagulator" (SBC). In this study, we aimed to optimize the SBC design with a prototyping process involving a bench test and preclinical study; then, we aimed to demonstrate the feasibility, safety, and potential effectiveness of the SBC for laparoscopic surgery in clinical settings. SBC prototyping was performed with a bench test. Device optimization was performed in a preclinical study with a domestic swine bleeding model. Then, SBC was tested in a clinical setting during 17 clinical laparoscopic colorectal surgeries. In the bench tests, two tip hole sizes and patterns showed a good suction capacity. The preclinical study indicated the best tip shape for accuracy. In clinical use, no device-related adverse event was observed. Moreover, the SBC was feasible for prompt hemostasis and blunt dissections. In addition, SBC could evacuate vapors generated by tissue ablation using electroprobe during laparoscopic surgery. We successfully developed a novel, integrated suction/coagulation probe for hemostasis and commercialized it.

  13. Reference Intervals of Routine Coagulation Assays During the Pregnancy and Puerperium Period.

    PubMed

    Gong, Jiao-Mei; Shen, Yong; He, Yan-Xia

    2016-11-01

    Significant changes occur in the coagulation and fibrinolytic systems during pregnancy and puerperium in the plasma levels. However, reference ranges based on healthy people are not optimal for informing clinical decisions during the pregnancy and puerperium. Therefore, it is essential to explore coagulation assays' reference ranges during the pregnancy and puerperium. Prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen (Fib.), and D-dimer were all measured according to the manufacturer's specifications and laboratory standard operating procedure of the STA-R evolution coagulation analyzer. A total of 11,601 women were enrolled in this study. The reference ranges for PT, APTT, TT, Fib., and D-dimer in nonpregnancy period were 10.87-13.76 s, 29.22-44.61 s, 15.39-20.15 s, 1.59-3.97 g/l, and 0-0.56 mg/l, respectively. In early-pregnancy period, the ranges were 11.14-14.07 s, 29.97-44.69 s, 14.92-19.03 s, 1.98-4.13 g/l, and 0-1.67 mg/l, respectively. In midpregnancy period, the ranges were 9.98-12.84 s, 28.53-40.70 s, 13.51-19.82 s, 2.63-5.19 g/l, and 0-2.81 mg/l, respectively. In late-pregnancy period, the ranges were 9.48-12.58 s, 28.61-40.80 s, 14.10-19.61 s, 2.80-5.56 g/l, and 0-27.08 mg/l, respectively. In puerperium period, the ranges were 10.85-13.72 s, 30.51-43.02 s, 15.31-19.64 s, 1.14-5.07 g/l, and 1.27-4.85 mg/l, respectively. We presented reference intervals for coagulation assays from the nonpregnancy to puerperium period that can be adopted in other laboratories after further validation. © 2016 Wiley Periodicals, Inc.

  14. Performance and Mechanisms of Ultrafiltration Membrane Fouling Mitigation by Coupling Coagulation and Applied Electric Field in a Novel Electrocoagulation Membrane Reactor.

    PubMed

    Sun, Jingqiu; Hu, Chengzhi; Tong, Tiezheng; Zhao, Kai; Qu, Jiuhui; Liu, Huijuan; Elimelech, Menachem

    2017-08-01

    A novel electrocoagulation membrane reactor (ECMR) was developed, in which ultrafiltration (UF) membrane modules are placed between electrodes to improve effluent water quality and reduce membrane fouling. Experiments with feedwater containing clays (kaolinite) and natural organic matter (humic acid) revealed that the combined effect of coagulation and electric field mitigated membrane fouling in the ECMR, resulting in higher water flux than the conventional combination of electrocoagulation and UF in separate units (EC-UF). Higher current densities and weakly acidic pH in the EMCR favored faster generation of large flocs and effectively reduced membrane pore blocking. The hydraulic resistance of the formed cake layers on the membrane surface in ECMR was reduced due to an increase in cake layer porosity and polarity, induced by both coagulation and the applied electric field. The formation of a polarized cake layer was controlled by the applied current density and voltage, with cake layers formed under higher electric field strengths showing higher porosity and hydrophilicity. Compared to EC-UF, ECMR has a smaller footprint and could achieve significant energy savings due to improved fouling resistance and a more compact reactor design.

  15. The first proton sponge-based amino acids: synthesis, acid-base properties and some reactivity.

    PubMed

    Ozeryanskii, Valery A; Gorbacheva, Anastasia Yu; Pozharskii, Alexander F; Vlasenko, Marina P; Tereznikov, Alexander Yu; Chernov'yants, Margarita S

    2015-08-21

    The first hybrid base constructed from 1,8-bis(dimethylamino)naphthalene (proton sponge or DMAN) and glycine, N-methyl-N-(8-dimethylamino-1-naphthyl)aminoacetic acid, was synthesised in high yield and its hydrobromide was structurally characterised and used to determine the acid-base properties via potentiometric titration. It was found that the basic strength of the DMAN-glycine base (pKa = 11.57, H2O) is on the level of amidine amino acids like arginine and creatine and its structure, zwitterionic vs. neutral, based on the spectroscopic (IR, NMR, mass) and theoretical (DFT) approaches has a strong preference to the zwitterionic form. Unlike glycine, the DMAN-glycine zwitterion is N-chiral and is hydrolytically cleaved with the loss of glycolic acid on heating in DMSO. This reaction together with the mild decarboxylative conversion of proton sponge-based amino acids into 2,3-dihydroperimidinium salts under air-oxygen was monitored with the help of the DMAN-alanine amino acid. The newly devised amino acids are unique as they combine fluorescence, strongly basic and redox-active properties.

  16. Air quality improvement during 2010 Asian games on blood coagulability in COPD patients.

    PubMed

    Zhang, Zili; Wang, Jian; Guo, Meihua; Xiong, Mingmei; Zhou, Qipeng; Li, Defu; Shu, Jiaze; Lu, Wenju; Sun, Dejun

    2016-04-01

    Exposure to elevated levels of ambient air pollutants can lead to adverse cardiovascular effects. Perturbation of the coagulation balance is one of the potential mechanisms. However, evidence regarding the impact of improvement in air pollution on blood coagulability in COPD patients has never been reported. Coagulation processes are known to be of relevance for cardiovascular pathology; therefore, this study aimed to investigate the association of short-term air pollution exposure with blood marker (D-dimer) of coagulation. A 3-year (through the Asian game) cohort study based on the GIRD COPD Biobank Project was conducted in 36 COPD patients to estimate whether changes in measurements of D-dimer were associated with changes in pollutant concentration, comparing for 51 intervention days (November 1-December 21) in 2010 with the same calendar date of baseline years (2009 and 2011). Daily mean concentrations of air pollutants and meteorological variables were measured during the time. Daily PM10 decreased from 65.86 μg/m(3) during the baseline period to 62.63 μg/m(3) during the Asian Games period; daily NO2 decreased from 51.33 to 42.63 μg/m(3). SO2 and other weather variables did not differ substantially. We did not observe statistically significant improvements in D-dimer levels by 9.86% from a pre-Asian game mean of 917 ng/ml to a during-Asian game mean of 1007 ng/ml, platelet number by 11.66%, PH by -0.15%, PCO2 by -6.54%, and PO2 by -1.16%. In the post-Asian game period, when pollutant concentrations increased, most outcomes approximated pre-Asian game levels, and similar effects were also demonstrated in D-dimer, platelet number, and arterial blood gas. For D-dimer and platelet number, we observed statistically significant increases associated with increases in NO2 at lag 1-3 and SO2 at lag 2-4. For PH, PCO2, and PO2, any significant effect was not demonstrated. This study gives no support to the hypothesis that reduction in air pollution levels during the

  17. Characterization of a microbial polysaccharide-based bioflocculant and its anti-inflammatory and pro-coagulant activity.

    PubMed

    Zhong, Chunying; Cao, Gang; Rong, Kuan; Xia, Zhengwu; Peng, Ting; Chen, Honggao; Zhou, Jiangang

    2018-01-01

    We describe a novel bioflocculant, MBF-15, which is an exopolysaccharide extracted from the alkaliphilic bacterium Paenibacillus jamilae. The biophysical characteristics of MBF-15 were determined using Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. MBF-15 was also evaluated for its biocompatibility by examining its inflammatory, coagulant, and hemostatic properties in vitro and in vivo. Pretreatment of peripheral blood mononuclear cells with MBF-15 inhibited lipopolysaccharide-stimulated expression of inducible nitric oxide synthase, production of nitric oxide, and secretion of pro-inflammatory cytokines, including tumor necrosis factor-α and interleukin-6. In addition, MBF-15 increased both mRNA and protein levels of the anti-inflammatory cytokines transforming growth factor-β and IL-10. The hemocompatibility of MBF-15 was investigated by measuring the hemolysis ratio and clotting times. MBF-15 had high pro-thrombogenic activity but was not hemolytic. In a rat model, MBF-15 showed superior hemostatic properties compared with chitosan. Thus, MBF-15 offers a promising combination of anti-inflammatory and pro-coagulant properties that may be useful for hemostasis in a variety of clinical settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Coagulation Imbalance and Neurocognitive Functioning in Older HIV+ Adults on Suppressive Antiretroviral Therapy

    PubMed Central

    Montoya, Jessica l.; Iudicello, Jennifer; Oppenheim, Hannah A.; Fazeli, Pariya l.; Potter, Michael; MA, Qing; Mills, Paul J.; Ellis, Ronald J.; Grant, Igor; Letendre, Scott l.; Moore, David J.

    2017-01-01

    Objectives To compare plasma biomarkers of coagulation between HIV-infected individuals and HIV-uninfected controls and to assess the impact of disturbances in coagulation on neurocognitive functioning in HIV. Design Cross-sectional study of 66 antiretroviral therapy-treated virally suppressed HIV-infected and 34 HIV-uninfected older (≥50 years of age) adults. Methods Participants completed standardized neurobehavioral and neuromedical assessments. Neurocognitive functioning was evaluated using a well-validated comprehensive neuropsychological battery. Plasma biomarkers associated with procoagulation (fibrinogen, p-selectin, tissue factor, and von Willebrand factor), anticoagulation (antithrombin, protein C, and thrombomodulin), fibrinolysis (d-dimer, plasminogen activator inhibitor-1, and plasminogen) were collected. Multivariable linear regression was used to test the interaction of HIV and coagulation on neurocognitive functioning. Results Most participants were male (78.0%) and non-Hispanic white (73.0%) with a mean age of 57.8 years. Among HIV-infected participants, mean estimated duration of HIV infection was 19.4 years and median current CD4+ cell count was 654 cells/mm3. Levels of soluble biomarkers of procoagulation, anticoagulation, and fibrinolysis were comparable between the HIV serostatus groups. Coagulation and HIV had an interacting effect on neurocognitive functioning, such that greater coagulation imbalance was associated with poorer neurocognitive functioning among the HIV-infected participants. The moderating effect of coagulation on neurocognition was driven by procoagulant but not anticoagulant or fibrinolytic biomarkers. Conclusions Elevated levels of procoagulants may exert a particularly detrimental effect on neurocognitive functioning among older HIV-infected persons. A better understanding of the specific role of coagulation in the etiology of HIV-associated neurocognitive disorders may lead to treatments aimed at reducing coagulopathy

  19. Performance Evaluation of the Sysmex CS-5100 Automated Coagulation Analyzer.

    PubMed

    Chen, Liming; Chen, Yu

    2015-01-01

    Coagulation testing is widely applied clinically, and laboratories increasingly demand automated coagulation analyzers with short turn-around times and high-throughput. The purpose of this study was to evaluate the performance of the Sysmex CS-5100 automated coagulation analyzer for routine use in a clinical laboratory. The prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (APTT), fibrinogen (Fbg), and D-dimer were compared between the Sysmex CS-5100 and Sysmex CA-7000 analyzers, and the imprecision, comparison, throughput, STAT function, and performance for abnormal samples were measured in each. The within-run and between-run coefficients of variation (CV) for the PT, APTT, INR, and D-dimer analyses showed excellent results both in the normal and pathologic ranges. The correlation coefficients between the Sysmex CS-5100 and Sysmex CA-7000 were highly correlated. The throughput of the Sysmex CS-5100 was faster than that of the Sysmex CA-7000. There was no interference at all by total bilirubin concentrations and triglyceride concentrations in the Sysmex CS-5100 analyzer. We demonstrated that the Sysmex CS-5100 performs with satisfactory imprecision and is well suited for coagulation analysis in laboratories processing large sample numbers and icteric and lipemic samples.

  20. A parametric comparative study of electrocoagulation and coagulation using ultrafine quartz suspensions.

    PubMed

    Kiliç, Mehtap Gülsün; Hoşten, Cetin; Demirci, Sahinde

    2009-11-15

    This paper attempts to compare electrocoagulation using aluminum anodes and stainless steel cathodes with conventional coagulation by aluminum sulfate dosing on aqueous suspensions of ultrafine quartz. Several key parameters affecting the efficiency of electrocoagulation and coagulation were investigated with laboratory scale experiments in search of optimal parameter values. Optimal values of the parameters were determined on the basis of the efficiency of turbidity removal from ultrafine quartz suspensions. The parameters investigated in the study were suspension pH, electrical potential, current density, electrocoagulation time, and aluminum dosage. A comparison between electrocoagulation and coagulation was made on the basis of total dissolved aluminum, revealing that electrocoagulation and coagulation were equally effective at the same aluminum dosage for the removal of quartz particles from suspensions. Coagulation, however, was more effective in a wider pH range (pH 6-9) than electrocoagulation which yielded optimum effectiveness in a relatively narrower pH range around 9, where, in both methods, these pH values corresponded to near-zero zeta potentials of quartz particles. Furthermore, experimental results confirmed that electrocoagulation could display some pH buffering capacity. The kinetics of electrocoagulation was very fast (<10 min) in approaching a residual turbidity, which could be modeled with a second-order rate equation.

  1. Influence of blood lipids on global coagulation test results.

    PubMed

    Kim, Jung-Ah; Kim, Ji-Eun; Song, Sang Hoon; Kim, Hyun Kyung

    2015-01-01

    High levels of blood lipids have been associated with high levels of coagulation factors. We investigated whether blood lipids influence the results of global coagulation tests, including prothrombin time (PT), activated partial thromboplastin time (aPTT), and thrombin generation assay (TGA). PT, aPTT, and TGA, along with procoagulant and anticoagulant factors, were measured in 488 normal individuals. Vitamin K status was assessed with prothrombin-induced by vitamin K absence-II (PIVKA-II). The procoagulant factors II, VII, IX, X, and XI and anticoagulant factors protein C and protein S showed significant correlations with triglyceride, and the procoagulant factors II, V, VII, IX, X, XI, and XII and anticoagulant factors antithrombin and protein C correlated with total cholesterol. There were no correlations of blood lipid levels with PIVKA-II levels. Subjects with high triglyceride levels (≥200 mg/dL) showed shorter PT values than those with lower triglyceride levels. However, aPTT value was not changed in terms of blood lipid levels. In both 1 and 5 pM tissue factor-induced TGAs, subjects in the high-triglyceride or high-cholesterol groups (≥240 mg/dL) had high levels of lag time, time-to-peak, and endogenous thrombin potential. Total cholesterol was a significant determinant of PT and TGA values. High blood lipids were related with increased coagulation activity in a normal population. Our findings are expected to help interpret the global coagulation test results in individuals with high lipid levels.

  2. Mathematical Modeling of Intravascular Blood Coagulation under Wall Shear Stress

    PubMed Central

    Rukhlenko, Oleksii S.; Dudchenko, Olga A.; Zlobina, Ksenia E.; Guria, Georgy Th.

    2015-01-01

    Increased shear stress such as observed at local stenosis may cause drastic changes in the permeability of the vessel wall to procoagulants and thus initiate intravascular blood coagulation. In this paper we suggest a mathematical model to investigate how shear stress-induced permeability influences the thrombogenic potential of atherosclerotic plaques. Numerical analysis of the model reveals the existence of two hydrodynamic thresholds for activation of blood coagulation in the system and unveils typical scenarios of thrombus formation. The dependence of blood coagulation development on the intensity of blood flow, as well as on geometrical parameters of atherosclerotic plaque is described. Relevant parametric diagrams are drawn. The results suggest a previously unrecognized role of relatively small plaques (resulting in less than 50% of the lumen area reduction) in atherothrombosis and have important implications for the existing stenting guidelines. PMID:26222505

  3. Fate of nanoparticles during alum and ferric coagulation monitored using single particle ICP-MS.

    PubMed

    Donovan, Ariel R; Adams, Craig D; Ma, Yinfa; Stephan, Chady; Eichholz, Todd; Shi, Honglan

    2018-03-01

    In this study, aluminum sulfate, ferric sulfate, ferric chloride, and poly(diallyldimethylammonium chloride) (pDADMAC) coagulation removal of citrate-stabilized silver and gold nanoparticles (NPs) and uncoated titanium dioxide, cerium dioxide, and zinc oxide NPs was investigated using a single particle (SP) ICP-MS direct monitoring technique. Zone 2 (charge neutralization) coagulation was performed in river water and more commonly used Zone 4 (sweep floc) coagulation was performed in both river and lake water with environmentally relevant concentrations of selected NPs added. SP-ICP-MS was used to detect NP and dissolved species, characterize the size distribution, and quantify particle concentration as well as dissolved species before and after treatments. Other parameters including pH, dissolved organic carbon, turbidity, and UV 254 absorbance were monitored to characterize treatment efficiency. Charge neutralization (Zone 2) coagulation resulted in 48-85% removal of citrate-stabilized NPs and 90-99% removal of uncoated NPs from river water. Sweep floc (Zone 4) coagulation in river water resulted in 36-94% removal of citrate-stabilized NPs and 91-99% removal of uncoated NPs both with and without polymer addition. Zone 4 coagulation conditions in lake water resulted in 77-98% removal of citrate-stabilized NPs and 59-96% removal of uncoated NPs without polymer. These results indicate that NP removal depends on NP surface and stability, the nature of the source water, and the coagulant type and approach. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Performance of coagulation tests in patients on therapeutic doses of rivaroxaban. A cross-sectional pharmacodynamic study based on peak and trough plasma levels.

    PubMed

    Francart, Suzanne J; Hawes, Emily M; Deal, Allison M; Adcock, Dorothy M; Gosselin, Robert; Jeanneret, Cheryl; Friedman, Kenneth D; Moll, Stephan

    2014-06-01

    Knowledge of anticoagulation status during rivaroxaban therapy is desirable in certain clinical situations. It was the study objective to determine coagulation tests most useful for assessing rivaroxaban's anticoagulant effect. Peak and trough blood samples from 29 patients taking rivaroxaban 20 mg daily were collected. Mass spectrometry and various coagulation assays were performed. "On-therapy range" was defined as the rivaroxaban concentrations determined by LC-MS/MS. A "misprediction percentage" was calculated based on how often results of each coagulation assay were in the normal reference range, while the rivaroxaban concentration was in the "on-therapy" range. The on-therapy range was 8.9-660 ng/ml. The misprediction percentages for prothrombin time (PT) and activated partial thromboplastin time (aPTT), using multiple reagents and coagulometers, ranged from 10%-52% and 31%-59%, respectively. PT, aPTT and activated clotting time (ACT) were insensitive to trough rivaroxaban: 59%, 62%, and 80% of samples had a normal result, respectively. Over 95% of PT and ACT values were elevated at peak. Four different rivaroxaban calibrated anti-Xa assays had R² values >0.98, demonstrating strong correlations with rivaroxaban drug levels. In conclusion, PT, aPTT and ACT are often normal in patients on therapeutic doses of rivaroxaban. However, PT and ACT may have clinical utility at higher drug plasma levels. Rivaroxaban calibrated anti-factor Xa assays can accurately identify low and high on-therapy rivaroxaban drug levels and, therefore, have superior utility in all clinical situations where assessment of anticoagulation status may be beneficial.

  5. Stress-sensitive arterial hypertension, haemodynamic changes and brain metabolites in hypertensive ISIAH rats: MRI investigation.

    PubMed

    Seryapina, A A; Shevelev, O B; Moshkin, M P; Markel, A L; Akulov, A E

    2017-05-01

    What is the central question of this study? Stress-sensitive arterial hypertension is considered to be controlled by changes in central and peripheral sympathetic regulating mechanisms, which eventually result in haemodynamic alterations and blood pressure elevation. Therefore, study of the early stages of development of hypertension is of particular interest, because it helps in understanding the aetiology of the disease. What is the main finding and its importance? Non-invasive in vivo investigation in ISIAH rats demonstrated that establishment of sustainable stress-sensitive hypertension is accompanied by a decrease in prefrontal cortex activity and mobilization of hypothalamic processes, with considerable correlations between haemodynamic parameters and individual metabolite ratios. The study of early development of arterial hypertension in association with emotional stress is of great importance for better understanding of the aetiology and pathogenesis of the hypertensive disease. Magnetic resonance imaging (MRI) was applied to evaluate the changes in haemodynamics and brain metabolites in 1- and 3-month-old inherited stress-induced arterial hypertension (ISIAH) rats (10 male rats) with stress-sensitive arterial hypertension and in control normotensive Wistar Albino Glaxo (WAG) rats (eight male rats). In the 3-month-old ISIAH rats, the age-dependent increase in blood pressure was associated with increased blood flow through the renal arteries and decreased blood flow in the lower part of the abdominal aorta. The renal vascular resistance in the ISIAH rats decreased during ageing, although at both ages it remained higher than the renal vascular resistance in WAG rats. An integral metabolome portrait demonstrated that development of hypertension in the ISIAH rats was associated with an attenuation of the excitatory and energetic activity in the prefrontal cortex, whereas in the WAG rats the opposite age-dependent changes were observed. In contrast, in the

  6. Coagulation-flocculation process applied to wastewaters generated in hydrocarbon-contaminated soil washing: Interactions among coagulant and flocculant concentrations and pH value.

    PubMed

    Torres, Luis G; Belloc, Claudia; Vaca, Mabel; Iturbe, Rosario; Bandala, Erick R

    2009-11-01

    Wastewater produced in the contaminated soil washing was treated by means of coagulation-flocculation (CF) process. The wastewater contained petroleum hydrocarbons, a surfactant, i.e., sodium dodecyl sulfate (SDS) as well as salts, brownish organic matter and other constituents that were lixiviated from the soil during the washing process. The main goal of this work was to develop a process for treating the wastewaters generated when washing hydrocarbon-contaminated soils in such a way that it could be recycled to the washing process, and also be disposed at the end of the process properly. A second objective was to study the relationship among the coagulant and flocculant doses and the pH at which the CF process is developed, for systems where methylene blue active substances (MBAS) as well as oil and greases were present. The results for the selection of the right coagulant and flocculant type and dose, the optimum pH value for the CF process and the interactions among the three parameters are detailed along this work. The best coagulant and flocculant were FeCl(3) and Tecnifloc 998 at doses of 4,000 and 1 mg/L, correspondingly at pH of 5. These conditions gave color, turbidity, chemical oxygen demand (COD) and conductivity removals of 99.8, 99.6, 97.1 and 35%, respectively. It was concluded that it is feasible to treat the wastewaters generated in the contaminated soil washing process through CF process, and therefore, wastewaters could be recycled to the washing process or disposed to drainage.

  7. Differential action of medically important Indian BIG FOUR snake venoms on rodent blood coagulation.

    PubMed

    Hiremath, Vilas; Nanjaraj Urs, A N; Joshi, Vikram; Suvilesh, K N; Savitha, M N; Urs Amog, Prathap; Rudresha, G V; Yariswamy, M; Vishwanath, B S

    2016-02-01

    Snakebite is a global health problem affecting millions of people. According to WHO, India has the highest mortality and/or morbidity due to snakebite. In spite of commendable research on Indian BIG FOUR venomous species; Naja naja and Bungarus caeruleus (elapid); Daboia russelii and Echis carinatus (viperid), no significant progress has been achieved in terms of diagnosis and management of biting species with appropriate anti-snake venom. Major hurdle is identification of offending species. Present study aims at differentiation of Indian BIG FOUR snake venoms based on their distinguish action on rodent blood coagulation. Assessment of coagulation alterations by elapid venoms showed negligible effect on re-calcification time, prothrombin time, activated partial thromboplastin time and factors assay (I, II, V, VIII and X) both in vitro and in vivo. However, viperid venoms demonstrated significant anticoagulant status due to their remarkable fibrinogen degradation potentials as supported by fibrinogenolytic activity, fibrinogen zymography and rotational thromboelastometry. Though results provide hint on probable alterations of Indian BIG FOUR snake venoms on blood coagulation, the study however needs validation from human victim's samples to ascertain its reliability for identification of biting snake species. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. A cluster of immunoresolvents links coagulation to innate host defense in human blood.

    PubMed

    Norris, Paul C; Libreros, Stephania; Chiang, Nan; Serhan, Charles N

    2017-08-01

    Blood coagulation is a protective response that prevents excessive bleeding upon blood vessel injury. We investigated the relationship between coagulation and the resolution of inflammation and infection by lipid mediators (LMs) through metabololipidomics-based profiling of human whole blood (WB) during coagulation. We identified temporal clusters of endogenously produced prothrombotic and proinflammatory LMs (eicosanoids), as well as specialized proresolving mediators (SPMs). In addition to eicosanoids, a specific SPM cluster was identified that consisted of resolvin E1 (RvE1), RvD1, RvD5, lipoxin B 4 , and maresin 1, each of which was present at bioactive concentrations (0.1 to 1 nM). Removal of adenosine from the coagulating blood markedly enhanced the amounts of SPMs produced and further increased the biosynthesis of RvD3, RvD4, and RvD6. The cyclooxygenase inhibitors celecoxib and indomethacin, which block the production of thromboxanes and prostanoids, did not block the production of clot-driven SPMs. Unbiased mass cytometry analysis demonstrated that the SPM cluster produced in human blood targeted leukocytes at the single-cell level, directly activating ERK and CREB signaling in neutrophils and CD14 + monocytes. Treatment of human WB with the components of this SPM cluster enhanced both the phagocytosis and killing of Escherichia coli by leukocytes. Together, these data identify a proresolving LM circuit, including endogenous molecular brakes and accelerators, which promoted host defense. These temporal LM-SPM clusters can provide accessible metabolomic profiles for precision and personalized medicine. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  9. Comprehensive reuse of drinking water treatment residuals in coagulation and adsorption processes.

    PubMed

    Jung, Kyung-Won; Hwang, Min-Jin; Park, Dae-Seon; Ahn, Kyu-Hong

    2016-10-01

    While drinking water treatment residuals (DWTRs) inevitably lead to serious problems due to their huge amount of generation and limitation of landfill sites, their unique properties of containing Al or Fe contents make it possible to reuse them as a beneficial material for coagulant recovery and adsorbent. Hence, in the present study, to comprehensively handle and recycle DWTRs, coagulant recovery from DWTRs and reuse of coagulant recovered residuals (CRs) were investigated. In the first step, coagulant recovery from DWTRs was conducted using response surface methodology (RSM) for statistical optimization of independent variables (pH, solid content, and reaction time) on response variable (Al recovery). As a result, a highly acceptable Al recovery of 97.5 ± 0.4% was recorded, which corresponds to 99.5% of the predicted Al recovery. Comparison study of recovered and commercial coagulant from textile wastewater treatment indicated that recovered coagulant has reasonable potential for use in wastewater treatment, in which the performance efficiencies were 68.5 ± 2.1% COD, 97.2 ± 1.9% turbidity, and 64.3 ± 1.0% color removals at 50 mg Al/L. Subsequently, in a similar manner, RSM was also applied to optimize coagulation conditions (Al dosage, initial pH, and reaction time) for the maximization of real cotton textile wastewater treatment in terms of COD, turbidity, and color removal. Overall performance revealed that the initial pH had a remarkable effect on the removal performance compared to the effects of other independent variables. This is mainly due to the transformation of metal species form with increasing or decreasing pH conditions. Finally, a feasibility test of CRs as adsorbent for phosphate adsorption from aqueous solution was conducted. Adsorption equilibrium of phosphate at different temperatures (10-30 °C) and initial levels of pH (3-11) indicated that the main mechanisms of phosphate adsorption onto CRs are endothermic and chemical

  10. Roles for vitamin K beyond coagulation

    USDA-ARS?s Scientific Manuscript database

    Recent interest in vitamin K has been motivated by evidence of physiological roles beyond that of coagulation. Vitamin K and vitamin K-dependent proteins may be involved in regulation of calcification, energy metabolism, and inflammation. However, the evidence for many of these proposed roles in the...

  11. 21 CFR 864.5400 - Coagulation instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...

  12. 21 CFR 864.5400 - Coagulation instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...

  13. 21 CFR 864.5400 - Coagulation instrument.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...

  14. 21 CFR 864.5400 - Coagulation instrument.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...

  15. 21 CFR 864.5400 - Coagulation instrument.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...

  16. Use of Tranexamic Acid Is Associated with Reduced Blood Product Transfusion in Complex Skull Base Neurosurgical Procedures: A Retrospective Cohort Study.

    PubMed

    Mebel, Dmitry; Akagami, Ryojo; Flexman, Alana M

    2016-02-01

    Compared with other procedures, complex skull base neurosurgery has the potential for increased intraoperative blood loss yet coagulation near eloquent cranial structures should be minimized. The safety and efficacy of the antifibrinolytic, tranexamic acid in elective neurosurgical procedures is not known. Our primary objective was to determine the relationship between the use of tranexamic acid and transfusion at our institution. Our secondary objective was to determine the incidence of adverse events associated with the use of tranexamic acid. In this retrospective cohort study, we included all patients who underwent complex skull base neurosurgical procedures at our institution between 2001 and 2013. Tranexamic acid was introduced during these procedures in 2006. Patient and surgical variables, transfusion data, and adverse events in the perioperative period were abstracted from the medical record. The rates of transfusion and adverse events were compared between patients who did and did not receive tranexamic acid. Multivariate regression was used to identify independent predictors of perioperative transfusion. We compared 245 patients who received tranexamic acid with 274 patients who did not receive the drug during the study period. The 2 groups were similar, with the exception that patients who received tranexamic acid had larger tumors (mean, 3.5 vs 2.9 cm; P < 0.001) and longer procedures (mean, 7.2 vs 6.2 hours, P < 0.001). The rate of perioperative transfusion in patients who received tranexamic acid was lower (7% vs 13%, P = 0.04). After adjusting for preoperative hemoglobin, tumor diameter, and surgical procedure category, the use of tranexamic acid was independently predictive of perioperative transfusion (adjusted odds ratio, 0.32; 95% confidence interval, 0.15-0.65, P = 0.002). The rates of thromboembolic events and seizure were similar between the 2 groups. Our results demonstrate that tranexamic acid use is associated with reduced transfusion

  17. Predicting haemodynamic networks using electrophysiology: The role of non-linear and cross-frequency interactions

    PubMed Central

    Tewarie, P.; Bright, M.G.; Hillebrand, A.; Robson, S.E.; Gascoyne, L.E.; Morris, P.G.; Meier, J.; Van Mieghem, P.; Brookes, M.J.

    2016-01-01

    Understanding the electrophysiological basis of resting state networks (RSNs) in the human brain is a critical step towards elucidating how inter-areal connectivity supports healthy brain function. In recent years, the relationship between RSNs (typically measured using haemodynamic signals) and electrophysiology has been explored using functional Magnetic Resonance Imaging (fMRI) and magnetoencephalography (MEG). Significant progress has been made, with similar spatial structure observable in both modalities. However, there is a pressing need to understand this relationship beyond simple visual similarity of RSN patterns. Here, we introduce a mathematical model to predict fMRI-based RSNs using MEG. Our unique model, based upon a multivariate Taylor series, incorporates both phase and amplitude based MEG connectivity metrics, as well as linear and non-linear interactions within and between neural oscillations measured in multiple frequency bands. We show that including non-linear interactions, multiple frequency bands and cross-frequency terms significantly improves fMRI network prediction. This shows that fMRI connectivity is not only the result of direct electrophysiological connections, but is also driven by the overlap of connectivity profiles between separate regions. Our results indicate that a complete understanding of the electrophysiological basis of RSNs goes beyond simple frequency-specific analysis, and further exploration of non-linear and cross-frequency interactions will shed new light on distributed network connectivity, and its perturbation in pathology. PMID:26827811

  18. Coagulation changes during lower body negative pressure and blood loss in humans.

    PubMed

    van Helmond, Noud; Johnson, Blair D; Curry, Timothy B; Cap, Andrew P; Convertino, Victor A; Joyner, Michael J

    2015-11-01

    We tested the hypothesis that markers of coagulation activation are greater during lower body negative pressure (LBNP) than those obtained during blood loss (BL). We assessed coagulation using both standard clinical tests and thrombelastography (TEG) in 12 men who performed a LBNP and BL protocol in a randomized order. LBNP consisted of 5-min stages at 0, -15, -30, and -45 mmHg of suction. BL included 5 min at baseline and following three stages of 333 ml of blood removal (up to 1,000 ml total). Arterial blood draws were performed at baseline and after the last stage of each protocol. We found that LBNP to -45 mmHg is a greater central hypovolemic stimulus versus BL; therefore, the coagulation markers were plotted against central venous pressure (CVP) to obtain stimulus-response relationships using the linear regression line slopes for both protocols. Paired t-tests were used to determine whether the slopes of these regression lines fell on similar trajectories for each protocol. Mean regression line slopes for coagulation markers versus CVP fell on similar trajectories during both protocols, except for TEG α° angle (-0.42 ± 0.96 during LBNP vs. -2.41 ± 1.13°/mmHg during BL; P < 0.05). During both LBNP and BL, coagulation was accelerated as evidenced by shortened R-times (LBNP, 9.9 ± 2.4 to 6.2 ± 1.1; BL, 8.7 ± 1.3 to 6.4 ± 0.4 min; both P < 0.05). Our results indicate that LBNP models the general changes in coagulation markers observed during BL. Copyright © 2015 the American Physiological Society.

  19. Pretreatment of water-based seed coating wastewater by combined coagulation and sponge-iron-catalyzed ozonation technology.

    PubMed

    Wen, Chen; Xu, Xiaoyi; Fan, Yunshuang; Xiao, Changfa; Ma, Cong

    2018-05-04

    Coagulation-sedimentation combined with sponge iron/ozone (CS-SFe/O 3 ) technology was applied to pretreat water-based seed coating wastewater (WSCW) from pesticide manufacturing. Coagulation with polyferric sulfate at a dosage of 1.5 g L -1 and a pH of 8.0 was effective, with color and chemical oxygen demand (COD) removal rates of 96.8 and 83.4%, respectively. SFe/O 3 treatment further reduced the organic content in the effluents, especially concerning the degradation of aromatic pollutants, as demonstrated via ultraviolet-visible spectrophotometry (UV-vis), excitation-emission matrix (EEM) fluorescence spectrometry, and gas chromatography-mass spectrometry (GC/MS) analyses. The residual color and COD values of the effluent were 581.0 times and 640.0 mg L -1 , respectively, under optimal conditions (ozone concentration of 0.48 mg L -1 , SFe dosage of 20.0 g L -1 , initial pH of 9.0, and reaction time of 30 min). Organic pollutants were also degraded by the high amounts of HO, which may have been generated via the transformation of ozone into HO on the SFe's surface and in the solution. Meanwhile, the biochemical oxygen demand (BOD 5 )/COD ratio of the WSCW increased, which indicates that the biodegradability improved significantly. The amount of iron leached from SFe particles was 4.5 mg L -1 , which shows that the SFe catalyst has good stability. The operating cost of the combined CS-SFe/O 3 technology was estimated at approximately 2.79 USD t -1 . The results of this study suggest that the application of the combined CS-SFe/O 3 technology in WSCW pretreatment can be beneficial for removing suspended solids, degrading recalcitrant pollutants, and enhancing biodegradability for the subsequent bioprocessing treatment. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Coagulation and complement activation.

    PubMed

    Christensen, K; Larsson, R; Emanuelsson, H; Elgue, G; Larsson, A

    2001-02-01

    The purpose of this investigation was to assess the effect of heparin coating of a new stent construction (Stent Graft, Jomed Implantate GmbH, Germany) on platelet and coagulation activity. Stent grafts with an ePTFE membrane interfoliated between two stents were deployed in tubings to form Chandler loops. Fresh human blood with a low concentration of heparin was rotated for 1 h, then collected and used for measurements of platelet number, thrombin-antithrombin complex (TAT), CD11b, C3a and C5b-9. There were five study groups: Group 1, conventional unmodified stents (n = 8); Group 2, untreated stent grafts (n = 8); Group 3, heparin-coated stents and untreated membrane (n = 7); Group 4, heparin-coated stents and membrane (n = 8); Group 5, heparin-coated PVC tubings with no stents (n = 8). There was a significant drop in platelet count, increase in TAT-values and CD11b expression in Groups 1-3 but not in Group 4 compared to Group 5. Examination by scanning electron microscopy revealed extensive activation on non-modified stents but almost no deposition of thrombotic material on heparin-modified stent grafts. With unmodified stents and membrane there were signs of significant activation of platelets and coagulation. In contrast, the heparin-coated stent graft induced much less alterations, indicating improved blood compatibility.

  1. Acetaminophen and meloxicam inhibit platelet aggregation and coagulation in blood samples from humans.

    PubMed

    Martini, Angela K; Rodriguez, Cassandra M; Cap, Andrew P; Martini, Wenjun Z; Dubick, Michael A

    2014-12-01

    Acetaminophen (Ace) and meloxicam (Mel) are the two types of analgesic and antipyretic medications. This study investigated the dose responses of acetaminophen and meloxicam on platelet aggregation and coagulation function in human blood samples. Blood samples were collected from six healthy humans and processed to make platelet-adjusted (100 × 10 cells/μl) blood samples. Acetaminophen (Tylenol, Q-PAP, 100 mg/ml) was added at the doses of 0 μg/ml (control), 214 μg/ml (the standard dose, 1 ×), 4 ×, 8 ×, 10 ×, 12 ×, 16 ×, and 20 ×. Similarly, meloxicam (Metacam, 5 mg/ml) was added at doses of 0 μg/ml (control), 2.85 μg/ml (the standard dose, 1 ×), 4 ×, 8 ×, 10 ×, 12 ×, 16 ×, and 20 ×. Fifteen minutes after the addition of acetaminophen and/or meloxicam, platelet aggregation was stimulated with collagen (2 μg/ml) or arachidonic acid (0.5 mmol/l) and assessed using a Chrono-Log 700 aggregometer. Coagulation function was assessed by prothrombin time (PT), activated partial thromboplastin time (aPTT), and using Rotem thrombelastogram. A robust inhibition by acetaminophen and/or meloxicam was observed in arachidonic acid-stimulated platelet aggregation starting at 1 × dose. Collagen-stimulated platelet aggregation was inhibited by ACE starting at 1 × (78 ± 10% of control), and by meloxicam starting at 4 × (72 ± 5% of control, both P < 0.05). The inhibitions by acetaminophen and meloxicam combined were similar to those by acetaminophen or meloxicam. aPTT was prolonged by meloxicam starting at 4 ×. No changes were observed in PT or any of Rotem measurements by acetaminophen and/or meloxicam. Acetaminophen and meloxicam compromised platelet aggregation and aPTT. Further effort is warranted to characterize the effects of acetaminophen and meloxicam on bleeding in vivo.

  2. Real-Time Electrical Impedimetric Monitoring of Blood Coagulation Process under Temperature and Hematocrit Variations Conducted in a Microfluidic Chip

    PubMed Central

    Lei, Kin Fong; Chen, Kuan-Hao; Tsui, Po-Hsiang; Tsang, Ngan-Ming

    2013-01-01

    Blood coagulation is an extremely complicated and dynamic physiological process. Monitoring of blood coagulation is essential to predict the risk of hemorrhage and thrombosis during cardiac surgical procedures. In this study, a high throughput microfluidic chip has been developed for the investigation of the blood coagulation process under temperature and hematocrit variations. Electrical impedance of the whole blood was continuously recorded by on-chip electrodes in contact with the blood sample during coagulation. Analysis of the impedance change of the blood was conducted to investigate the characteristics of blood coagulation process and the starting time of blood coagulation was defined. The study of blood coagulation time under temperature and hematocrit variations was shown a good agreement with results in the previous clinical reports. The electrical impedance measurement for the definition of blood coagulation process provides a fast and easy measurement technique. The microfluidic chip was shown to be a sensitive and promising device for monitoring blood coagulation process even in a variety of conditions. It is found valuable for the development of point-of-care coagulation testing devices that utilizes whole blood sample in microliter quantity. PMID:24116099

  3. Method of removing arsenic and other anionic contaminants from contaminated water using enhanced coagulation

    DOEpatents

    Teter, David M.; Brady, Patrick V.; Krumhansl, James L.; Khandaker, Nadim R.

    2006-11-21

    An improved water decontamination process comprising contacting water containing anionic contaminants with an enhanced coagulant to form an enhanced floc, which more efficiently binds anionic species (e.g., arsenate, arsenite, chromate, fluoride, selenate, and borate, and combinations thereof) predominantly through the formation of surface complexes. The enhanced coagulant comprises a trivalent metal cation coagulant (e.g., ferric chloride or aluminum sulfate) mixed with a divalent metal cation modifier (e.g., copper sulfate or zinc sulfate).

  4. Comparative thermometric coagulation studies of plasmas from normal outbred Swiss Webster mice and persons.

    PubMed

    Tsang, V C; Wyatt, C R; Damian, R T

    1979-06-01

    The functional capabilities of a thermometric clot-timer have been demonstrated in a comparative study of human and mouse plasma coagulation. The influence of some variables on coagulation times of mouse and human plasmas were examined in activated partial thromboplastin time, one-stage prothrombin time, and Russell's viper venom time assays. Mouse plasma coagulation times were generally shorter and more reproducible than those of human plasma. Optimal assay conditions are also described.

  5. Experimental dosing of wetlands with coagulants removes mercury from surface water and decreases mercury bioaccumulation in fish

    USGS Publications Warehouse

    Ackerman, Joshua T.; Kraus, Tamara E.C.; Fleck, Jacob A.; Krabbenhoft, David P.; Horwarth, William R.; Bachand, Sandra M.; Herzog, Mark; Hartman, Christopher; Bachand, Philip A.M.

    2015-01-01

    Mercury pollution is widespread globally, and strategies for managing mercury contamination in aquatic environments are necessary. We tested whether coagulation with metal-based salts could remove mercury from wetland surface waters and decrease mercury bioaccumulation in fish. In a complete randomized block design, we constructed nine experimental wetlands in California’s Sacramento–San Joaquin Delta, stocked them with mosquitofish (Gambusia affinis), and then continuously applied agricultural drainage water that was either untreated (control), or treated with polyaluminum chloride or ferric sulfate coagulants. Total mercury and methylmercury concentrations in surface waters were decreased by 62% and 63% in polyaluminum chloride treated wetlands and 50% and 76% in ferric sulfate treated wetlands compared to control wetlands. Specifically, following coagulation, mercury was transferred from the filtered fraction of water into the particulate fraction of water which then settled within the wetland. Mosquitofish mercury concentrations were decreased by 35% in ferric sulfate treated wetlands compared to control wetlands. There was no reduction in mosquitofish mercury concentrations within the polyaluminum chloride treated wetlands, which may have been caused by production of bioavailable methylmercury within those wetlands. Coagulation may be an effective management strategy for reducing mercury contamination within wetlands, but further studies should explore potential effects on wetland ecosystems.

  6. Experimental dosing of wetlands with coagulants removes mercury from surface water and decreases mercury bioaccumulation in fish.

    PubMed

    Ackerman, Joshua T; Kraus, Tamara E C; Fleck, Jacob A; Krabbenhoft, David P; Horwath, William R; Bachand, Sandra M; Herzog, Mark P; Hartman, C Alex; Bachand, Philip A M

    2015-05-19

    Mercury pollution is widespread globally, and strategies for managing mercury contamination in aquatic environments are necessary. We tested whether coagulation with metal-based salts could remove mercury from wetland surface waters and decrease mercury bioaccumulation in fish. In a complete randomized block design, we constructed nine experimental wetlands in California's Sacramento-San Joaquin Delta, stocked them with mosquitofish (Gambusia affinis), and then continuously applied agricultural drainage water that was either untreated (control), or treated with polyaluminum chloride or ferric sulfate coagulants. Total mercury and methylmercury concentrations in surface waters were decreased by 62% and 63% in polyaluminum chloride treated wetlands and 50% and 76% in ferric sulfate treated wetlands compared to control wetlands. Specifically, following coagulation, mercury was transferred from the filtered fraction of water into the particulate fraction of water which then settled within the wetland. Mosquitofish mercury concentrations were decreased by 35% in ferric sulfate treated wetlands compared to control wetlands. There was no reduction in mosquitofish mercury concentrations within the polyaluminum chloride treated wetlands, which may have been caused by production of bioavailable methylmercury within those wetlands. Coagulation may be an effective management strategy for reducing mercury contamination within wetlands, but further studies should explore potential effects on wetland ecosystems.

  7. Enhancement of sedimentation and coagulation with static magnetic field

    NASA Astrophysics Data System (ADS)

    Zieliński, Marcin; Dębowski, Marcin; Hajduk, Anna; Rusanowska, Paulina

    2017-11-01

    The static magnetic field can be an alternative method for wastewater treatment. It has been proved that this physical factor, accelerates the biochemical processes, catalyzes advanced oxidation, intensifies anaerobic and aerobic processes or reduces swelling of activated sludge. There are also reports proving the positive impact of the static magnetic field on the coagulation and sedimentation, as well as the conditioning and dewatering of sludge. In order to be applied in larger scale the published results should be verified and confirmed. In the studies, the enhancement of sedimentation by the static magnetic field was observed. The best sedimentation was noted in the experiment, where magnetizers were placed on activated sludge bioreactor and secondary settling tank. No effect of the static magnetic field on coagulation with the utilization of PIX 113 was observed. However, the static magnetic field enhanced coagulation with the utilization of PAX-XL9. The results suggest that increased sedimentation of colloids and activated sludge, can in practice mean a reduction in the size of the necessary equipment for sedimentation with an unchanged efficiency of the process.

  8. Influence of the Mixing Energy Consumption Affecting Coagulation and Floc Aggregation.

    PubMed

    Vadasarukkai, Yamuna S; Gagnon, Graham A

    2017-03-21

    The operational significance of energy-intensive rapid mixing processes remains unaddressed in coagulation and flocculation of insoluble precipitates (flocs), which play an important role in the removal of impurities from drinking water supplies. In this study, the influence of rapid mixing and associated mixing energy on floc aggregation was examined for a surface water source characterized by a high fraction of aquatic humic matter. Infrared spectral analyses showed that the colloidal complexes resulting from ligand exchange between iron and dissolved natural organic matter (DOM) were not substantially influenced by the mixing energy input. This signified that DOM removal by coagulation can be achieved at lower mixing intensity, thereby reducing energy consumption. In contrast, macroscopic investigations showed the coagulation mixing energy affected floc size distributions during the slow mixing stage in flocculation and, to some extent, their settling characteristics. The results from analysis of floc properties clearly showed that more mixing energy was expended than necessary in coagulation, which is typically designed at a high mixing intensity range of 600-1000 s -1 in treatment plants. The key findings from this study have practical implications to water utilities to strategically meet water quality goals while reducing energy demands.

  9. Differential roles of tissue factor and phosphatidylserine in activation of coagulation.

    PubMed

    Spronk, Henri M H; ten Cate, Hugo; van der Meijden, Paola E J

    2014-05-01

    It has been suggested that the main physiological trigger of coagulation, tissue factor, possesses limited procoagulant activity and occurs in an inactive or so-called encrypted state. For the conversion of encrypted into decrypted tissue factor with sufficient procoagulant activity, four distinct models have been proposed: 1; dimer formation, 2; lipid rafts, 3; disulfide bonds, and 4; phosphatidylserine exposure. Pro and cons can be given for each of these mechanisms of tissue factor encryption/decryption, however, it seems most likely that two or more mechanisms act together in activating the procoagulant activity. The exposure of phosphatidylserine in the outer layer of cell membranes supports coagulation through enhanced formation of the tenase (factors IXa, VIIIa and X) and prothrombinase (factors Xa, Va and prothrombin) complexes. The proposed role for phosphatidylserine in decryption of tissue factor could contribute to the correct orientation of the tissue factor - factor VII complex. Overall, the contribution of both tissue factor and phosphatidylserine to coagulation seems distinct with tissue factor being the physiological activator and phosphatidylserine the driving force of propagation of coagulation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Composite wastewater treatment by aerated electrocoagulation and modified peroxi-coagulation processes.

    PubMed

    Kumar, Abhijeet; Nidheesh, P V; Suresh Kumar, M

    2018-08-01

    Treatment of composite wastewater generating from the industrial estates is a great challenge. The present study examines the applicability of aerated electrocoagulation and modified peroxi-coagulation processes for removing color and COD from composite wastewater. Iron plates were used as anodes and cathodes in both electrochemical processes and experiments were carried out in a working volume of 2 L. Aeration enhanced the efficiency of electrocoagulation process significantly. More than 50% of COD and 60% of color were removed after 1 h of electrocoagulation process operated at pH 3 and applied voltage of 1 V. Efficiency of the modified peroxi-coagulation process was significantly higher than that of aerated electrocoagulation. COD and color removal efficiencies of the modified peroxi-coagulation process were found as 77.7% and 97%, respectively after 1 h of electrolysis operated at 1 V, solution pH 3 and 50 mM hydrogen peroxide addition. This improved efficiency of modified peroxi-coagulation compared to aerated electrocoagulation is mainly due to the attack of in-situ generated hydroxyl radicals. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Simple and rapid methods for purification and characterization of active coagulants from the seeds of Vigna unguiculata and Parkinsonia aculeata.

    PubMed

    Marobhe, N J; Dalhammar, G; Gunaratna, K R

    2007-06-01

    The coagulating properties of aqueous crude extracts and purified proteins of Vigna unguiculata and Parkinsonia aculeata seeds, which are traditional water coagulants in rural areas of Tanzania, were studied. The coagulation activity assays were done using one millilitre (ml) of kaolin water samples. Coagulating proteins were purified in two-step ion exchange chromatography. The properties of coagulant protein were compared with Moringa oleifera. Coagulating components eluted by 0.6 M NaCl in both coagulants are cationic proteins that have the molecular mass of about 6 kDa, which is very similar to that of M. oleifera. The proteins of V. unguiculata and P. aculeata eluted by 0.3 M NaCl also harbour coagulation activity but proteins eluted with 0.6 M NaCl have higher activity. The dosage for coagulation using purified proteins of both coagulants is about 5 to 10 times lower than that of crude seed extracts. The optimum floc settling time of water treated by crude seed extracts and purified proteins ranged between two and two and half hours. Coagulating proteins of both coagulants eluted by 0.6 M NaCl are thermoresistant and retained coagulation activity of 87% to 92% after boiling for two hours at 80 degrees C and one hour at 95 degrees C. Thermotolerant proteins of V. unguiculata eluted by 0.6 M NaCl and P. aculeata have wider pH range of 5.5 to 8.5 for coagulation activity than those of M. oleifera proteins. The present investigation reveals the possibility of using purified natural coagulants for water treatment to produce safe drinking water.

  12. Coagulation of dust grains in the plasma of an RF discharge in argon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mankelevich, Yu. A.; Olevanov, M. A.; Pal', A. F.

    2009-03-15

    Results are presented from experimental studies of coagulation of dust grains of different sizes injected into a low-temperature plasma of an RF discharge in argon. A theoretical model describing the formation of dust clusters in a low-temperature plasma is developed and applied to interpret the results of experiments on the coagulation of dust grains having large negative charges. The grain size at which coagulation under the given plasma conditions is possible is estimated using the developed theory. The theoretical results are compared with the experimental data.

  13. Comparison of the Effects of Thiopental Sodium and Propofol on Haemodynamics, Awareness and Newborns During Caesarean Section Under General Anaesthesia.

    PubMed

    Çakırtekin, Vedat; Yıldırım, Ahmet; Bakan, Nurten; Çelebi, Nevin; Bozkurt, Özkan

    2015-04-01

    To compare the effects of propofol and thiopental on haemodynamics, awareness and newborns in pregnant women undergoing elective caesarean section. Seventy pregnant women were assigned into two equal groups. For anaesthesia induction, 2 mg kg(-1) propofol (Group P) and 5 mg kg(-1) thiopental (Group T) were administered. Maternal haemodynamic parameters and bispectral index (BIS) values were recorded before induction, in 1-minute intervals within the first 10 minutes after induction and in 5-minute intervals thereafter, during skin incision, uterine incision, removal of infant, uterine sutures, skin sutures, eye opening and extubation in all cases. Cord blood gas analysis and 1- and 5-minute APGAR scores were recorded. In all cases, a keyword was spelled to ear during removal of the infant, and at the first postoperative hour, patients were questioned. Important time periods of surgery and anaesthesia and also the first postoperative hour haemodynamic values, pain scores, nausea and vomiting were noted. The demographic data were similar among cases. In Group T, systolic arterial pressure (SAP), diastolic arterial pressure (DAP) and mean arterial pressure (MAP) at the first 2 minutes after induction and heart rate (HR) at almost all time points were significantly higher. BIS values from induction to the eighth minute and skin incision, uterine incision and removal of the infant were lower in Group P. No patient remembered the keyword spelled, while 4 patients reported dreaming during general anaesthesia. The effects of propofol and thiopental sodium on 1- and 5-minute APGAR scores, cord blood gas values and postoperative visual analogue scale (VAS) scores were similar. Propofol is a more appropriate anaesthetic agent than thiopental in anaesthesia for caesareans, since it provides better anaesthestic depth and more rapid recovery.

  14. Transcatheter aortic valve implantation of a second-generation valve for pure aortic regurgitation: procedural outcome, haemodynamic data and follow-up.

    PubMed

    Schlingloff, Friederike; Schäfer, Ulrich; Frerker, Christian; Schmoeckel, Michael; Bader, Ralf

    2014-09-01

    The second-generation Jenavalve prosthesis (Jenavalve Technology, Inc., Munich, Germany) is the first transcatheter valve Conformité Européene (CE) marked for treatment of both aortic stenosis (AS) and pure aortic regurgitation (AR). Although the feasibility of the Jenavalve transcatheter aortic valve implantation (TAVI) in patients with pure AR has been described, haemodynamic and follow-up data are lacking. We report on a series of 10 transapical Jenavalve implantations for pure AR between December 2012 and September 2013. The patients were determined for TAVI by heart team decision at high surgical risk [log EuroSCORE (European System for Cardiac Operative Risk Evaluation) >20%], frailty or Charlson Comorbidity Index (CCI). Transaortic gradients and right heart haemodynamics were measured invasively before and after TAVI. Ventriculography and transoesophageal echocardiography were used to determine paravalvular regurgitation. All-cause mortality, NYHA functional class and echocardiographic measurements were followed up at 30 days and at 3, 9 and 12 months postoperatively. Overall, mean age was 79 ± 9 years, mean left ventricular ejection fraction 50 ± 17% and mean log EuroSCORE 28.3 ± 17.1%. There were no perioperative complications. Paravalvular regurgitation immediately after implantation was graded none (n = 6), trace (n = 3) or mild (n = 1). Overall 30-day mortality was 30% (3/10). Three patients refused further treatment, such as haemodialysis or treatment of mitral regurgitation. Rate for pacemaker implantation was 2/10 (20%). Intraprocedural success and haemodynamic data in our cases were good. The mortality in our group highlighted the importance of careful patient selection, especially for this pathology. The Jenavalve prosthesis proved to be suitable for treatment of AR in surgical high-risk patients. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Morphologic characteristics of central pulmonary thromboemboli predict haemodynamic response in massive pulmonary embolism.

    PubMed

    Podbregar, Matej; Voga, Gorazd; Krivec, Bojan

    2004-08-01

    On hospital admission, the morphology of the central pulmonary artery thromboemboli is an independent predictor of 30-day mortality in patients with massive pulmonary embolism (MPE). This may be due to the differential susceptibility of thromboemboli to thrombolysis. The aim of this study was to assess haemodynamic response to treatment in patients with MPE and morphologically different thromboemboli. Prospective observational study. An 11-bed closed medical ICU at a 860-bed community general hospital. Twelve consecutive patients with shock or hypotension due to MPE and central pulmonary thromboemboli detected by transesophageal echocardiography who were treated with thrombolysis between January 2000 through April 2002. Patients were divided into two groups according to the characteristics of detected central pulmonary thromboemboli: group 1, thrombi with one or more long, mobile parts; and group 2, immobile thrombi. Urokinase infusion was terminated when mixed venous oxygen saturation was stabilized above 60% for 15 min. At 2 h, the total pulmonary vascular resistance index was reduced more in group 1 than group 2 [from 27+/-12 mmHg/(l.min.m(2)) to 14+/-6 mmHg/(l.min.m(2)) (-52%) vs 27+/-8 mmHg/(l.min.m(2)) to 23+/-10 mmHg/(l.min.m(2)) (-15%), respectively, P=0.04]. In group 1 thrombolysis was terminated earlier than group 2 (89+/-40 min vs 210+/-62 min, respectively, P= 0.0024). The cumulative dose of urokinase used in group 1 was lower than group 2 (1.7+/-0.3 M i.u. vs 2.7+/-0.5 M i.u., respectively, P= 0.023). Haemodynamic stabilization is achieved faster in patients with mobile central thromboemboli detected by transesophageal echocardiography during MPE.

  16. Reduced plasma levels of coagulation factors in relation to prostate cancer.

    PubMed

    Beecken, Wolf-Dietrich; Bentas, Wassilios; Engels, Knut; Glienke, Wolfgang; Urbschat, Anja; Jonas, Dietger; Binder, Jochen; Scharrer, Inge

    2002-10-01

    Prostate cancer has historically been associated with coagulation abnormalities. This study was undertaken to investigate the prevalence of abnormalities of coagulation factors in patients with prostate cancer before and after radical prostatectomy (RP). Because coagulation factors have been shown to be involved in tumor angiogenesis, the vascular density of the prostate tumors was assessed. Plasma of 40 consecutive patients with histologically proven prostate cancer was investigated pre-RP and post-RP. The antigen level for antithrombin, plasminogen activator inhibitor-1, and heparin cofactor-II, and the plasma activity of antithrombin and plasminogen were determined by using immunologic and chromogenic assays. The values of these assays were compared with a group of 28 male, age-matched patients without any evidence of cancer and 18 patients with orthopedic interventions preoperatively and postoperatively. The vascular density of the prostate tumors was assessed by staining paraffin sections with an antibody to CD34. The median plasma antigen levels and/or activities of the investigated factors were below normal in the prostate cancer patients before RP. Furthermore, coagulation factors were significantly lower than in the age-matched control group and patients before and after orthopedic surgery. In prostate cancer patients, the median values of all investigated factors went up to normal levels within 2 weeks after RP, whereas postsurgical levels in orthopedic patients remained stable. No correlations to tumor parameters have been observed. We assume that the reduction of these coagulation factors is a principle concept in prostate cancer that needs further investigation. Copyright 2002 Wiley-Liss, Inc.

  17. Proteins, Platelets, and Blood Coagulation at Biomaterial Interfaces

    PubMed Central

    Xu, Li-Chong; Bauer, James; Siedlecki, Christopher A.

    2015-01-01

    Blood coagulation and platelet adhesion remain major impediments to the use of biomaterials in implantable medical devices. There is still significant controversy and question in the field regarding the role that surfaces play in this process. This manuscript addresses this topic area and reports on state of the art in the field. Particular emphasis is placed on the subject of surface engineering and surface measurements that allow for control and observation of surface-mediated biological responses in blood and test solutions. Appropriate use of surface texturing and chemical patterning methodologies allow for reduction of both blood coagulation and platelet adhesion, and new methods of surface interrogation at high resolution allow for measurement of the relevant biological factors. PMID:25448722

  18. Action of Nanoparticles on Platelet Activation and Plasmatic Coagulation

    PubMed Central

    Fröhlich, Eleonore

    2016-01-01

    Nanomaterials can get into the blood circulation after injection or by release from implants but also by permeation of the epithelium after oral, respiratory or dermal exposure. Once in the blood, they can affect hemostasis, which is usually not intended. This review addresses effects of biological particles and engineered nanomaterials on hemostasis. The role of platelets and coagulation in normal clotting and the interaction with the immune system are described. Methods to identify effects of nanomaterials on clotting and results from in vitro and in vivo studies are summarized and the role of particle size and surface properties discussed. The literature overview showed that mainly pro-coagulative effects of nanomaterials have been described. In vitro studies suggested stronger effects of smaller than of larger NPs on coagulation and a greater importance of material than of surface charge. For instance, carbon nanotubes, polystyrene particles, and dendrimers inferred with clotting independent from their surface charge. Coating of particles with polyethylene glycol was able to prevent interaction with clotting by some particles, while it had no effect on others and the more recently developed bio-inspired surfaces might help to design coatings for more biocompatible particles. The mainly pro-coagulative action of nanoparticles could present a particular risk for individuals affected by common diseases such as diabetes, cancer, and cardiovascular diseases. Under standardized conditions, in vitro assays using human blood appear to be a suitable tool to study mechanisms of interference with hemostasis and to optimize hemocompatibility of nanomaterials. PMID:26063498

  19. Influence of Blood Lipids on Global Coagulation Test Results

    PubMed Central

    Kim, Jung-Ah; Kim, Ji-Eun; Song, Sang Hoon

    2015-01-01

    Background High levels of blood lipids have been associated with high levels of coagulation factors. We investigated whether blood lipids influence the results of global coagulation tests, including prothrombin time (PT), activated partial thromboplastin time (aPTT), and thrombin generation assay (TGA). Methods PT, aPTT, and TGA, along with procoagulant and anticoagulant factors, were measured in 488 normal individuals. Vitamin K status was assessed with prothrombin-induced by vitamin K absence-II (PIVKA-II). Results The procoagulant factors II, VII, IX, X, and XI and anticoagulant factors protein C and protein S showed significant correlations with triglyceride, and the procoagulant factors II, V, VII, IX, X, XI, and XII and anticoagulant factors antithrombin and protein C correlated with total cholesterol. There were no correlations of blood lipid levels with PIVKA-II levels. Subjects with high triglyceride levels (≥200 mg/dL) showed shorter PT values than those with lower triglyceride levels. However, aPTT value was not changed in terms of blood lipid levels. In both 1 and 5 pM tissue factor-induced TGAs, subjects in the high-triglyceride or high-cholesterol groups (≥240 mg/dL) had high levels of lag time, time-to-peak, and endogenous thrombin potential. Total cholesterol was a significant determinant of PT and TGA values. Conclusion High blood lipids were related with increased coagulation activity in a normal population. Our findings are expected to help interpret the global coagulation test results in individuals with high lipid levels. PMID:25553275

  20. The role of coagulation/fibrinolysis during Streptococcus pyogenes infection.

    PubMed

    Loof, Torsten G; Deicke, Christin; Medina, Eva

    2014-01-01

    The hemostatic system comprises platelet aggregation, coagulation and fibrinolysis and is a host defense mechanism that protects the integrity of the vascular system after tissue injury. During bacterial infections, the coagulation system cooperates with the inflammatory system to eliminate the invading pathogens. However, pathogenic bacteria have frequently evolved mechanisms to exploit the hemostatic system components for their own benefit. Streptococcus pyogenes, also known as Group A Streptococcus, provides a remarkable example of the extraordinary capacity of pathogens to exploit the host hemostatic system to support microbial survival and dissemination. The coagulation cascade comprises the contact system (also known as the intrinsic pathway) and the tissue factor pathway (also known as the extrinsic pathway), both leading to fibrin formation. During the early phase of S. pyogenes infection, the activation of the contact system eventually leads to bacterial entrapment within a fibrin clot, where S. pyogenes is immobilized and killed. However, entrapped S. pyogenes can circumvent the antimicrobial effect of the clot by sequestering host plasminogen on the bacterial cell surface that, after conversion into its active proteolytic form, plasmin, degrades the fibrin network and facilitates the liberation of S. pyogenes from the clot. Furthermore, the surface-localized fibrinolytic activity also cleaves a variety of extracellular matrix proteins, thereby enabling S. pyogenes to migrate across barriers and disseminate within the host. This review summarizes the knowledge gained during the last two decades on the role of coagulation/fibrinolysis in host defense against S. pyogenes as well as the strategies developed by this pathogen to evade and exploit these host mechanisms for its own benefit.

  1. [Experimental investigations of coagulation possibilities of noncoherent optico-electronic systems in operations on parenchymatous organs].

    PubMed

    Sukhin, I A; Furmanov, Iu O; Kozhukhar, O T; Savits'ka, I M; Kachan, S H; Bililovets', O M; Savits'kiĭ, O V

    2012-03-01

    Results of experimental investigation on elaboration and trial of surgical hemostasis method, using the quartz heating optic noncoherent irradiators of light, are adduced. Basing on analysis of the results obtained, the apparatus for photooptic coagulation was elaborated and trialed on experimental animals.

  2. Complexity in Acid-Base Titrations: Multimer Formation Between Phosphoric Acids and Imines.

    PubMed

    Malm, Christian; Kim, Heejae; Wagner, Manfred; Hunger, Johannes

    2017-08-10

    Solutions of Brønsted acids with bases in aprotic solvents are not only common model systems to study the fundamentals of proton transfer pathways but are also highly relevant to Brønsted acid catalysis. Despite their importance the light nature of the proton makes characterization of acid-base aggregates challenging. Here, we track such acid-base interactions over a broad range of relative compositions between diphenyl phosphoric acid and the base quinaldine in dichloromethane, by using a combination of dielectric relaxation and NMR spectroscopy. In contrast to what one would expect for an acid-base titration, we find strong deviations from quantitative proton transfer from the acid to the base. Even for an excess of the base, multimers consisting of one base and at least two acid molecules are formed, in addition to the occurrence of proton transfer from the acid to the base and simultaneous formation of ion pairs. For equimolar mixtures such multimers constitute about one third of all intermolecular aggregates. Quantitative analysis of our results shows that the acid-base association constant is only around six times larger than that for the acid binding to an acid-base dimer, that is, to an already protonated base. Our findings have implications for the interpretation of previous studies of reactive intermediates in organocatalysis and provide a rationale for previously observed nonlinear effects in phosphoric acid catalysis. © 2017 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  3. Coagulation of dust particles in a plasma

    NASA Technical Reports Server (NTRS)

    Horanyi, M.; Goertz, C. K.

    1990-01-01

    The electrostatic charge of small dust grains in a plasma in which the temperature varies in time is discussed, pointing out that secondary electron emission might introduce charge separation. If the sign of the charge on small grains is opposite to that on big ones, enhanced coagulation can occur which will affect the size distribution of grains in a plasma. Two scenarios where this process might be relevant are considered: a hot plasma environment with temperature fluctuations and a cold plasma environment with transient heating events. The importance of the enhanced coagulation is uncertain, because the plasma parameters in grain-producing environments such as a molecular cloud or a protoplanetary disk are not known. It is possible, however, that this process is the most efficient mechanism for the growth of grains in the size range of 0.1-500 microns.

  4. Coagulation indices in very preterm infants from cord blood and postnatal samples.

    PubMed

    Neary, E; McCallion, N; Kevane, B; Cotter, M; Egan, K; Regan, I; Kirkham, C; Mooney, C; Coulter-Smith, S; Ní Áinle, F

    2015-11-01

    Very premature infants are at high risk of bleeding complications; however, few data exist on ranges for standard coagulation tests. The primary objective of this study was to measure standard plasma coagulation tests and thrombin generation in very premature infants compared with term infants. The secondary objective was to evaluate whether an association existed between coagulation indices and intraventricular hemorrhage (IVH). Cord and peripheral blood of neonates < 30 weeks gestational age (GA) was drawn at birth, on days 1 and 3 and fortnightly until 30 weeks corrected gestational age. Prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen and coagulation factor levels were measured and tissue factor-stimulated thrombin generation was characterized. Control plasma was obtained from cord blood of term neonates. One hundred and sixteen infants were recruited. Median (range) GA was 27.7 (23.7-29.9) weeks and mean (SD) birth weight was 1020 (255) g. Median (5th-95th percentile) day 1 PT, APTT and fibrinogen were 17.5 (12.7-26.6) s, 78.7 (48.7-134.3) s and 1.4 (0.72-3.8) g L(-1) , respectively. No difference in endogenous thrombin potential between preterm and term plasma was observed, where samples were available. Levels of coagulation factors II, VII, IX and X, protein C, protein S and antithrombin were reduced in preterm compared with term plasma. Day 1 APTT and PT were not associated with IVH. In the largest cross-sectional study to date of very preterm infants, typical ranges for standard coagulation tests were determined. Despite long clotting times, thrombin generation was observed to be similar in very preterm and term infants. © 2015 International Society on Thrombosis and Haemostasis.

  5. [The relationship between ophthalmic nerve lesion in glaucoma and ocular and systemic haemodynamic disturbance].

    PubMed

    Liu, L; Yuan, S; Yang, W

    1999-04-01

    To explore the relationship between the optic nerve lesion in glaucoma and ocular and systemic haemodynamic disturbance. The color Doppler imaging was used to study blood velocity in the ophthalmic, the central retinal and the short posterior ciliary arteries in 34 patients with primary open angle glaucoma, 31 patients with low tension glaucoma and 90 healthy controls. The peak systolic velocity(PSV), the end diastolic velocity (EDV) and resistive index (RI) in each artery were measured, moreover the nailfold microcirculation and blood viscosity in each patient were examined. Compared with the control group, the PSV and EDV of the central retinal arteries were significantly lower while the RI of the central retinal arteries was significantly higher in both POAG and LTG patients. The RI of the short posterior ciliary arteries however was significantly higher in POAG. Nailfold microcirculation shows that some important parameters, including flow pattern, loop surrounding, morphological weighted value, total weighted value and capillary deformity rate in the two glaucoma groups were higher, whereas the flow velocity was lower than in the control group. The plasm viscosity and the whole blood viscosity (low spear) were higher than normal. According to our measurements, the nailfold microcirculation and blood viscosity was worse at the end stage of glaucoma than at early stage. The correlative analysis between measurement results of color doppler imaging and microcirculation and heamorrheology showed that nailfold microcirculation morphological weighted value was negatively correlated with the EDV of the central retinal artery and positively correlated with the RI of the central retinal artery in LTG patients. The abnormity of ocular haemodynamics and systemic microcirculation and blood viscosity is one important factor of optic nerve damage in glaucoma.

  6. Coagulation imbalance and neurocognitive functioning in older HIV-positive adults on suppressive antiretroviral therapy.

    PubMed

    Montoya, Jessica L; Iudicello, Jennifer; Oppenheim, Hannah A; Fazeli, Pariya L; Potter, Michael; Ma, Qing; Mills, Paul J; Ellis, Ronald J; Grant, Igor; Letendre, Scott L; Moore, David J

    2017-03-27

    The aim of this study was to compare plasma biomarkers of coagulation between HIV-infected individuals and HIV-uninfected controls and to assess the impact of disturbances in coagulation on neurocognitive functioning in HIV. A cross-sectional study of 66 antiretroviral therapy treated, virally suppressed, HIV-infected and 34 HIV-uninfected older (≥50 years of age) adults. Participants completed standardized neurobehavioral and neuromedical assessments. Neurocognitive functioning was evaluated using a well validated comprehensive neuropsychological battery. Plasma biomarkers associated with procoagulation (fibrinogen, p-selectin, tissue factor and von Willebrand factor), anticoagulation (antithrombin, protein C and thrombomodulin), fibrinolysis (d-dimer, plasminogen activator inhibitor-1 and plasminogen) were collected. Multivariable linear regression was used to test the interaction of HIV and coagulation on neurocognitive functioning. Most participants were male (78.0%) and non-Hispanic white (73.0%) with a mean age of 57.8 years. Among HIV-infected participants, mean estimated duration of HIV infection was 19.4 years and median current CD4 cell count was 654 cells/μl. Levels of soluble biomarkers of procoagulation, anticoagulation and fibrinolysis were comparable between the HIV serostatus groups. Coagulation and HIV had an interacting effect on neurocognitive functioning, such that greater coagulation imbalance was associated with poorer neurocognitive functioning among the HIV-infected participants. The moderating effect of coagulation on neurocognition was driven by procoagulant but not anticoagulant or fibrinolytic biomarkers. Elevated levels of procoagulants may exert a particularly detrimental effect on neurocognitive functioning among older HIV-infected persons. A better understanding of the specific role of coagulation in the cause of HIV-associated neurocognitive disorders may lead to treatments aimed at reducing coagulopathy, thereby improving

  7. Genotoxicity testing of cooked cured meat pigment (CCMP) and meat emulsion coagulates prepared with CCMP.

    PubMed

    Stevanović, M; Cadez, P; Zlender, B; Filipic, M

    2000-07-01

    The preformed cooked cured meat pigment (CCMP) synthesized directly from bovine red blood cells or through a hemin intermediate was found to be a viable colorant for application to comminuted pork as a nitrite substitute. However the genotoxicity of CCMP and meat emulsion coagulates prepared with CCMP has not been evaluated. Therefore the objectives of this work were to investigate genotoxicity of CCMP and the influence of CCMP addition on genotoxicity and the content of residual nitrite in model meat emulsion coagulates. Meat emulsions were prepared from white (musculus longissimus dorsi) and red (musculus quadriceps femoris) pork muscles with two different amounts of synthesized pigment CCMP. Comparatively, emulsions with fixed addition of nitrite salt and emulsions without any addition for color development were made. Genotoxicity of CCMP and meat emulsion coagulates was tested with the SOS/umu test and the Ames test. Neither CCMP nor meat emulsion coagulates prepared with CCMP or nitrite salt were genotoxic in the SOS/umu test. In the Ames test using Salmonella Typhimurium strains TA98 and TA100 samples of coagulates prepared with CCMP and with nitrite showed weak mutagenic activity in Salmonella Typhimurium strain TA100 but only in the absence of the metabolic activation, while CCMP was not mutagenic. Coagulates prepared with CCMP contained significantly less residual nitrite than coagulates prepared with nitrite salt. These results indicate that from the human health standpoint the substitution of nitrite salt with CCMP would be highly recommendable.

  8. Surgical Coagulator With Carbon Dioxide Laser For Gynecology

    NASA Astrophysics Data System (ADS)

    Wolinski, Wieslaw; Kazmirowski, Antoni; Korobowicz, Witold; Olborski, Zbigniew

    1987-10-01

    The technical data and parameters of the CO2 surgical laser for gynecology are given. Coagulator was designed and constructed in Institute of Microelectronics and Optoelectronics Warsaw Technical University.

  9. Synthesis of new kojic acid based unnatural α-amino acid derivatives.

    PubMed

    Balakrishna, C; Payili, Nagaraju; Yennam, Satyanarayana; Uma Devi, P; Behera, Manoranjan

    2015-11-01

    An efficient method for the preparation of kojic acid based α-amino acid derivatives by alkylation of glycinate schiff base with bromokojic acids have been described. Using this method, mono as well as di alkylated kojic acid-amino acid conjugates have been prepared. This is the first synthesis of C-linked kojic acid-amino acid conjugate where kojic acid is directly linked to amino acid through a C-C bond. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Whole blood coagulation analyzers.

    PubMed

    1997-08-01

    Whole blood Coagulation analyzers (WBCAs) are widely used point-of-care (POC) testing devices found primarily in cardiothoracic surgical suites and cardia catheterization laboratories. Most of these devices can perform a number of coagulation tests that provide information about a patient's blood clotting status. Clinicians use the results of the WBCA tests, which are available minutes after applying a blood sample, primarily to monitor the effectiveness of heparin therapy--an anticoagulation therapy used during cardiopulmonary bypass (CPB) surgery, angioplasty, hemodialysis, and other clinical procedures. In this study we evaluated five WBCAs from four suppliers. Our testing focused on the applications for which WBCAs are primarily used: Monitoring moderate to high heparin levels, as would be required, for example, during CPB are angioplasty. For this function, WCBAs are typically used to perform an activated clotting time (ACT) test or, as one supplier refers to its test, a heparin management test (HMT). All models included in this study offered an ACT test or an HMT. Monitoring low heparin levels, as would be required, for example,during hemodialysis. For this function, WBCAs would normally be used to perform either a low-range ACT (LACT) test or a whole blood activated partial thromboplastin time (WBAPTT) test. Most of the evaluated units could perform at least one of these tests; one unit did not offer either test and was therefore not rated for this application. We rated and ranked each evaluated model separately for each of these two applications. In addition, we provided a combined rating and ranking that considers the units' appropriateness for performing both application. We based our conclusions on a unit's performance and humans factor design, as determined by our testing, and on its five-year life-cycle cost, as determined by our net present value (NPV) analysis. While we rated all evaluated units acceptable for each appropriate category, we did

  11. Coagulation profiles of healthy Andalusian donkeys are different than those of healthy horses.

    PubMed

    Mendoza, F J; Perez-Ecija, R A; Monreal, L; Estepa, J C

    2011-01-01

    Coagulation disorders are frequently diagnosed, especially in hospitalized equidae, and result in increased morbidity and mortality. However, hemostatic reference intervals have not been established for donkeys yet. To determine whether the most common coagulation parameters used in equine practice are different between healthy donkeys and horses. Thirty-eight healthy donkeys and 29 healthy horses. Blood samples were collected to assess both coagulation and fibrinolytic systems by determination of platelet count, fibrinogen concentration, clotting times (prothrombin time [PT] and activated partial thromboplastin time [aPTT]), fibrin degradation products (FDP) and D-Dimer concentrations. PT and aPTT in donkeys were significantly (P < .05) shorter than those of horses. In contrast, FDP and D-Dimer concentrations were significantly (P < .05) higher in donkeys than in horses. The coagulation parameters most commonly determined in equine practice are different in donkeys compared with horses. Thus, the use of normal reference ranges reported previously for healthy horses in donkeys might lead to a misdiagnosis of coagulopathy in healthy donkeys, and unnecessary treatments in sick donkeys. This is the first report of normal coagulation profile results in donkeys, and further studies are warranted to elucidate the physiological mechanisms of the differences observed between donkeys and horses. Copyright © 2011 by the American College of Veterinary Internal Medicine.

  12. Haemodynamic stability during general anaesthesia for intra-ocular surgery: the effect of topical oxybuprocaine.

    PubMed

    Lytle, J; Thomas, N F

    1992-07-01

    Local anaesthesia is frequently used in combination with light general anaesthesia to reduce the reflex responses to surgical stimulation. This combination has not previously been evaluated for intra-ocular surgery. During cataract extraction under general anaesthesia, the effect of topical anaesthesia with oxybuprocaine 0.4% on the pressor response was compared with normal saline in a control group. The simple technique of instilling local anaesthetic drops into the conjunctival sac blocked the pain pathway sufficiently to prevent the pressor response to surgical stimulation (p less than 0.001). Higher inspired concentrations of enflurane were required in the control group to achieve and maintain haemodynamic stability (p less than 0.001).

  13. Contribution of Fe3O4 nanoparticles to the fouling of ultrafiltration with coagulation pre-treatment

    PubMed Central

    Yu, Wenzheng; Xu, Lei; Graham, Nigel; Qu, Jiuhui

    2015-01-01

    A coagulation (FeCl3)-ultrafiltration process was used to treat two different raw waters with/without the presence of Fe3O4 nanoparticle contaminants. The existence of Fe3O4 nanoparticles in the raw water was found to increase both irreversible and reversible membrane fouling. The trans-membrane pressure (TMP) increase was similar in the early stages of the membrane runs for both raw waters, while it increased rapidly after about 15 days in the raw water with Fe3O4 nanoparticles, suggesting the involvement of biological effects. Enhanced microbial activity with the presence of Fe3O4 nanoparticles was evident from the measured concentrations of extracellular polymeric substances (EPS) and deoxyribonucleic acid (DNA), and fluorescence intensities. It is speculated that Fe3O4 nanoparticles accumulated in the cake layer and increased bacterial growth. Associated with the bacterial growth is the production of EPS which enhances the bonding with, and between, the coagulant flocs; EPS together with smaller sizes of the nano-scale primary particles of the Fe3O4-CUF cake layer, led to the formation of a lower porosity, more resilient cake layer and membrane pore blockage. PMID:26268589

  14. Percutaneous transcatheter arterial embolization in haemodynamically stable patients with blunt splenic injury

    PubMed Central

    Popovic, Peter; Stanisavljevic, Dragoje; Jeromel, Miran

    2010-01-01

    Background The nonoperative management of the blunt splenic injury in haemodynamically stable patients has become an accepted treatment in recent years. We present a case of the blunt splenic injury successfully treated by supraselective embolization with microspheres. Case report. A young hockey player was brought to the Emergency Department with the history of blunt abdominal trauma 2 h earlier. A Grade III splenic injury with haemoperitoneum was diagnosed on sonographic evaluation and the patient was treated with the selective distal splenic artery embolization with microspheres. Postprocedural ultrasound and computed tomography follow-up a year later revealed only a small area of parenchymal irregularity. Conclusions The percutaneous splenic arterial embolization has a major role in the management of traumatic splenic injuries. Embolization is particularly beneficial in injuries of grade III or higher. PMID:22933888

  15. Effect of Hemodilution on Coagulation and Recombinant Factor VIIa Efficacy in Human Blood In Vitro

    DTIC Science & Technology

    2011-11-01

    thrombasthenia.12 In trauma, when a blood vessel is injured, tissue factor on subendothelial pericytes is exposed and binds to endogenous FVII ...a more complex effect on coagulation than simply dilution of any single coagulation factor like FVII or fibrinogen (Fig. 1). It is interesting to note...ORIGINAL ARTICLE Effect of Hemodilution on Coagulation and Recombinant Factor VIIa Efficacy in Human Blood In Vitro Daniel N. Darlington, PhD, Angel

  16. Coagulation phenotypes in septic shock as evaluated by calibrated automated thrombography.

    PubMed

    Perrin, Julien; Charron, Cyril; François, Jean-Hugues; Cramer-Bordé, Elisabeth; Lévy, Bruno; Borgel, Delphine; Vieillard-Baron, Antoine

    2015-01-01

    Sepsis induces alterations of coagulation suggesting both hypercoagulable or hypocoagulable features. The result of their combination remains unknown, making it difficult to predict whether one prevails over the other. Thrombin generation tests (TGTs) stand as an interesting tool to establish an integrative phenotype of coagulation. It has been reported that septic patients display a hypocoagulable trait using TGT. However, protein C (PC) system response was not evaluated. We aimed at describing the thrombin generation profile in patients with septic shock under conditions that are sensitive to PC system to evaluate the net results of coagulation abnormalities and to determine whether hypercoagulable or hypocoagulable traits coexist within a given individual. Thrombin generation was studied in plasma from patients presenting with septic shock at diagnosis and 6 h after a conventional therapeutic management using calibrated automated thrombography with or without thrombomodulin (TM) addition. Patients exhibit clear alterations of TGT that present as both consumption-related hypocoagulability (evidenced without TM addition) but also hypercoagulability by decreased sensitivity to the PC system evidenced with TM addition. No difference could be demonstrated between survivors and nonsurvivors at Day 28, but patients who do not respond to therapeutics at 6 h seem to be more hypercoagulable. More importantly, if our results evidence heterogeneity between patients, we show that alterations of coagulation result in an equilibrium in the majority of patients, thus suggesting "normocoagulability"; but, in the presence of a biological imbalance between baseline thrombin generation and sensitivity to TM, the global effect mostly tends toward hypercoagulability. Thus, TGT may help identify distinct biological coagulation phenotypes in the complex alterations induced by sepsis.

  17. Research of combined adsorption-coagulation process in treating petroleum refinery effluent.

    PubMed

    Wang, Bing; Shui, Yiyu; Ren, Hongyang; He, Min

    2017-02-01

    The petroleum refinery industry generates a significant amount of wastewater that contains a high level of organic matter, which calls for effective and costly treatments. In this research, the effectiveness of the petroleum refinery effluent (PRE) treatment with physicochemical process of combined adsorption and coagulation was evaluated. The effects of initial pH, hydraulic condition , and combined sequence of treatment process, different treating reagent types and dosages on the chemical oxygen demand (COD) removal were investigated. Additionally, the elimination efficiency of pollutant wastewater was monitored by gas chromatography-mass spectrometry (GC-MS), and Fourier transformed infrared (FT-IR) spectrophotometer was adopted to describe the structure of the wastewater. Wooden activated carbon was chosen as adsorbent at the dosage of 10 g/L as a primary treatment, and 1500 mg/L polymeric magnesium ferric sulfate was used in coagulation. Results showed that adsorption and subsequent coagulation displayed the best performance when initial pH was 9 at shear rates (G) of G1 = 65 s -1 and G2 = 20 s -1 , which reached maximal removal rate of COD and total organic carbon GC-MS testing result revealed that adsorption was effective in phenols and iso-alkanes removal, whereas coagulation was good at removing esters and n-alkanes.

  18. Congenital combined deficiency of coagulation factors: a study of seven patients.

    PubMed

    Naderi, Majid; Tabibian, Shadi; Hosseini, Maryam Sadat; Alizadeh, Shaban; Hosseini, Soudabeh; Shamsizadeh, Morteza; Dorgalaleh, Akbar

    2015-01-01

    Combined deficiency of coagulation factors is considered as an extremely rare bleeding disorder (RBD) inherited in an autosomal recessive pattern. This disorder is more likely to occur in regions with a high rate of consanguineous marriages or in restricted communities. Sistan and Baluchistan, a province in southeast of Iran with a high rate of consanguinity, is a clear model of such regions with a very high prevalence of recessively inherited disorders. The aim of this study was to report the frequency of combined factor deficiency in this province. This descriptive study was conducted on 358 patients with RBD. Demographic information and medical history of each patient were recorded, and the patients were examined by a physician. Routine screening tests were carried out for all patients, and further coagulation tests including coagulation factor activity and antigen assays were subsequently performed for all suspected patients. Among 358 patients, four were found to be affected with combined factor (F)V and FVIII deficiency (F5F8D). In addition, one patient with combined deficiency of FVII-FXIII, one with combined FVII-FX and one with combined FVIII-FIX deficiency were identified. In Sistan and Baluchistan Province, coinheritance of recessively inherited disorders like combined coagulation factor deficiencies was surprisingly higher than expected.

  19. The effects of nanomaterials on blood coagulation in hemostasis and thrombosis.

    PubMed

    Simak, Jan; De Paoli, Silvia

    2017-09-01

    The blood coagulation balance in the organism is achieved by the interaction of the blood platelets (PLTs) with the plasma coagulation system (PCS) and the vascular endothelial cells. In healthy organism, these systems prevent thrombosis and, in events of vascular damage, enable blood clotting to stop bleeding. The dysregulation of hemostasis may cause serious thrombotic and/or hemorrhagic pathologies. Numerous engineered nanomaterials are being investigated for biomedical purposes and are unavoidably exposed to the blood. Also, nanomaterials may access vascular system after occupational, environmental, or other types of exposure. Thus, it is essential to evaluate the effects of engineered nanomaterials on hemostasis. This review focuses on investigations of nanomaterial interactions with the blood components involved in blood coagulation: the PCS and PLTs. Particular emphases include the pathophysiology of effects of nanomaterials on the PCS, including the kallikrein-kinin system, and on PLTs. Methods for investigating these interactions are briefly described, and a review of the most important studies on the interactions of nanomaterials with plasma coagulation and platelets is provided. WIREs Nanomed Nanobiotechnol 2017, 9:e1448. doi: 10.1002/wnan.1448 For further resources related to this article, please visit the WIREs website. © Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  20. Effect of a physical activity programme in the aquatic environment on haemodynamic constants in pregnant women.

    PubMed

    Vázquez-Lara, Juana María; Ruiz-Frutos, Carlos; Rodríguez-Díaz, Luciano; Ramírez-Rodrigo, Jesús; Villaverde-Gutiérrez, Carmen; Torres-Luque, Gema

    2017-09-20

    To evaluate the effect of a physical activity programme in the aquatic environment with immersion up to the neck, of six weeks duration, on haemodynamic constants in pregnant women. A six-week physical activity programme in the aquatic environment was carried out with a total of 46 pregnant women, who were distributed into an experimental group (n = 18), which participated in the programme, and a control group (n = 28), which followed routine care. In both groups different haemodynamic measurements were evaluated before and after the program. At the beginning of the programme the mean systolic blood pressure was similar between groups, but diastolic blood pressure was slightly higher in the experimental group. When the measurements at the last session were compared, arterial pressures (systolic, diastolic and mean) were significantly higher in the control group (p <.050). Similarly, the initial plasma volume values did not differ between groups, but after the intervention, the control group women showed a higher mean (p <.010). The fraction of sodium excretion (FENa) increased significantly in the experimental group, after the programme, with a mean three times higher (p <.050). Aldosterone plasma levels did not show significant differences between the groups in the different measurements. A programme of swimming and immersion exercises in pregnant women contributes to hydrosaline balance, preventing an excessive increase in usual plasma volume during pregnancy and in the activity of the renin-aldosterone axis. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  1. The Intrinsic Pathway of Coagulation as a Target for Antithrombotic Therapy

    PubMed Central

    Wheeler, Allison P.; Gailani, David

    2016-01-01

    Plasma coagulation in the activated partial thromboplastin time assay is initiated by sequential activation of coagulation factors XII, XI and IX – the classical intrinsic pathway of coagulation. It is well recognized that this series of proteolytic reactions is not an accurate model for hemostasis in vivo, as factor XII deficiency does not cause abnormal bleeding, and fXI deficiency causes a relatively mild propensity to bleed excessively with injury. Despite their limited roles in hemostasis, there is mounting evidence that fXI and fXII contribute to thrombosis, and that inhibiting them can produce an antithrombotic effect with a relatively small effect on hemostasis. In this chapter the contributions of components of the intrinsic pathway to thrombosis in animal models and humans are discussed, and results of early clinical trials of drugs targeting factors IX, XI and XII are presented. PMID:27637310

  2. Upon admission coagulation and platelet function in patients with thermal and electrical injuries.

    PubMed

    Wade, Charles E; Baer, Lisa A; Cardenas, Jessica C; Folkerson, Lindley E; Nutall-Aurora, Kisha; Cotton, Bryan A; Matijevic, Nena; Holcomb, John B; Cross, James M; Huzar, Todd

    2016-12-01

    There has been increased focus on hemostatic potential and function in the initial assessment of the patient with traumatic injuries, that not been extensively studied in patients with burns. We proposed to determine the hemostatic potential of patients with burns upon admission to the emergency department and contrasted their condition with that of healthy controls and patients with other traumatic injuries. In addition we assessed differences due to thermal versus electrical injury and evaluated the effect of burn size. This is a patient based prospective observational study conducted with delayed consented. Subjects at the highest level of trauma activation upon admission to the ED had a blood sample collected for research purposes and were subsequently consented. Hemostatic potential was measured by rapid thromelastography (r-TEG ® ), thrombin generation by calibrated automated thrombogram (CAT) and platelet function by Multiplate ® using five activators. Burn subjects were compared to subjects with other traumatic injuries and controls. Within the burn subjects additional analysis compared mechanism (thermal vs. electrical) and burn size. Values are medians (IQR). Two hundred and eighty two trauma patients (with burns n=40, 14%) and 27 controls were enrolled. Upon admission, compared to controls, subjects with burns or trauma were hyper-coagulable based on r-TEG and CAT, with increased rates of clot formation and thrombin generation. There were no differences in burns compared to other traumatic injuries. The presence of hyper-coagulation did not appear to be related to the type of burn or the percentage of total body surface area involved. Employing previous defined cut points for R-TEG driven therapeutic interventions burn patients had similar rates of hyper- and hypo-coagulation noted in patients with traumatic injuries. Upon admission patients with burns are in a hyper-coagulable state similar to that of other trauma patients. Employing demonstrated cut

  3. Commonly Used Dietary Supplements on Coagulation Function during Surgery

    PubMed Central

    Wang, Chong-Zhi; Moss, Jonathan; Yuan, Chun-Su

    2015-01-01

    Abstract Background Patients who undergo surgery appear to use dietary supplements significantly more frequently than the general population. Because they contain pharmacologically active compounds, dietary supplements may affect coagulation and platelet function during the perioperative period through direct effects, pharmacodynamic interactions, and pharmacokinetic interactions. However, in this regard, limited studies have been conducted that address the pharmacological interactions of dietary supplements. To avoid possible bleeding risks during surgery, information about the potential complications of dietary supplements during perioperative management is important for physicians. Methods Through a systematic database search of all available years, articles were identified in this review if they included dietary supplements and coagulation/platelet function, while special attention was paid to studies published after 1990. Results Safety concerns are reported in commercially available dietary supplements. Effects of the most commonly used natural products on blood coagulation and platelet function are systematically reviewed, including 11 herbal medicines (echinacea, ephedra, garlic, ginger, ginkgo, ginseng, green tea, kava, saw palmetto, St John’s wort, and valerian) and four other dietary supplements (coenzyme Q10, glucosamine and chondroitin sulfate, fish oil, and vitamins). Bleeding risks of garlic, ginkgo, ginseng, green tea, saw palmetto, St John’s wort, and fish oil are reported. Cardiovascular instability was observed with ephedra, ginseng, and kava. Pharmacodynamic and pharmacokinetic interactions between dietary supplements and drugs used in the perioperative period are discussed. Conclusions To prevent potential problems associated with the use of dietary supplements, physicians should be familiar with the perioperative effects of commonly used dietary supplements. Since the effects of dietary supplements on coagulation and platelet function are

  4. The role of coagulation/fibrinolysis during Streptococcus pyogenes infection

    PubMed Central

    Loof, Torsten G.; Deicke, Christin; Medina, Eva

    2014-01-01

    The hemostatic system comprises platelet aggregation, coagulation and fibrinolysis and is a host defense mechanism that protects the integrity of the vascular system after tissue injury. During bacterial infections, the coagulation system cooperates with the inflammatory system to eliminate the invading pathogens. However, pathogenic bacteria have frequently evolved mechanisms to exploit the hemostatic system components for their own benefit. Streptococcus pyogenes, also known as Group A Streptococcus, provides a remarkable example of the extraordinary capacity of pathogens to exploit the host hemostatic system to support microbial survival and dissemination. The coagulation cascade comprises the contact system (also known as the intrinsic pathway) and the tissue factor pathway (also known as the extrinsic pathway), both leading to fibrin formation. During the early phase of S. pyogenes infection, the activation of the contact system eventually leads to bacterial entrapment within a fibrin clot, where S. pyogenes is immobilized and killed. However, entrapped S. pyogenes can circumvent the antimicrobial effect of the clot by sequestering host plasminogen on the bacterial cell surface that, after conversion into its active proteolytic form, plasmin, degrades the fibrin network and facilitates the liberation of S. pyogenes from the clot. Furthermore, the surface-localized fibrinolytic activity also cleaves a variety of extracellular matrix proteins, thereby enabling S. pyogenes to migrate across barriers and disseminate within the host. This review summarizes the knowledge gained during the last two decades on the role of coagulation/fibrinolysis in host defense against S. pyogenes as well as the strategies developed by this pathogen to evade and exploit these host mechanisms for its own benefit. PMID:25309880

  5. Commonly Used Dietary Supplements on Coagulation Function during Surgery.

    PubMed

    Wang, Chong-Zhi; Moss, Jonathan; Yuan, Chun-Su

    2015-09-01

    Patients who undergo surgery appear to use dietary supplements significantly more frequently than the general population. Because they contain pharmacologically active compounds, dietary supplements may affect coagulation and platelet function during the perioperative period through direct effects, pharmacodynamic interactions, and pharmacokinetic interactions. However, in this regard, limited studies have been conducted that address the pharmacological interactions of dietary supplements. To avoid possible bleeding risks during surgery, information of potential complications of dietary supplements during perioperative management is important for physicians. Through a systematic database search of all available years, articles were identified in this review if they included dietary supplements and coagulation/platelet function, while special attention was paid to studies published after 1990. Safety concerns are reported in commercially available dietary supplements. Effects of the most commonly used natural products on blood coagulation and platelet function are systematically reviewed, including 11 herbal medicines (echinacea, ephedra, garlic, ginger, ginkgo, ginseng, green tea, kava, saw palmetto, St John's wort, and valerian) and 4 other dietary supplements (coenzyme Q 10 , glucosamine and chondroitin sulfate, fish oil, and vitamins). Bleeding risks of garlic, ginkgo, ginseng, green tea, saw palmetto, St John's wort, and fish oil are reported. Cardiovascular instability was observed with ephedra, ginseng, and kava. Pharmacodynamic and pharmacokinetic interactions between dietary supplements and drugs used in the perioperative period are discussed. To prevent potential problems associated with the use of dietary supplements, physicians should be familiar with the perioperative effects of commonly used dietary supplements. Since the effects of dietary supplements on coagulation and platelet function are difficult to predict, it is prudent to advise their

  6. Monitoring and treatment of coagulation abnormalities in burn patients. an international survey on current practices

    PubMed Central

    Lavrentieva, A.; Depetris, N.; Kaimakamis, E.; Berardino, M.; Stella, M.

    2016-01-01

    Summary The magnitude of coagulation abnormalities, and the definition and treatment of coagulopathy in burn patients are inadequately understood and continue to be discussed in the literature. We aimed to analyse physicians’ views on monitoring and treating coagulation abnormalities in burn patients. A total of 350 questionnaires were distributed electronically to burn ICU physicians. Participation was voluntary and anonymous. Responses were analysed electronically and comparisons were made according to the region of the ICU or the specialty of the physician. Of the 350 questionnaires distributed, 55 (15.7%) were returned. The majority of burn specialists consider sepsis-induced coagulopathy to be the most frequent coagulopathy in burn patients, and 74.5% declare that they do not use any specific definition/scoring system in their department to detect coagulopathy. The majority of specialists (70.8%) use standard coagulation tests. The most frequent indications for plasma transfusion are massive bleeding (32.8%) and Disseminated Intravascular Coagulation syndrome treatment (20%). The main specific factors reported in our study are cryoprecipitate (23.2%) and fibrinogen concentrate (18.9%). 21.1% of respondents state that they do not use any specific coagulation factor substitution in burn patients. Specific coagulation factor substitution is not a routine practice. The low response rate precludes the generalization of our results. PMID:28149244

  7. The impact of pre-oxidation with potassium permanganate on cyanobacterial organic matter removal by coagulation.

    PubMed

    Naceradska, Jana; Pivokonsky, Martin; Pivokonska, Lenka; Baresova, Magdalena; Henderson, Rita K; Zamyadi, Arash; Janda, Vaclav

    2017-05-01

    The study investigates the effect of permanganate pre-oxidation on the coagulation of peptides/proteins of Microcystis aeruginosa which comprise a major proportion of the organic matter during cyanobacterial bloom decay. Four different permanganate dosages (0.1, 0.2, 0.4 and 0.6 mg KMnO 4 mg -1 DOC) were applied prior to coagulation by ferric sulphate. Moreover, changes in sample characteristics, such as UV 254 , DOC content and molecular weight distribution, after pre-oxidation were monitored. The results showed that permanganate pre-oxidation led to a reduction in coagulant dose, increased organic matter removals by coagulation (by 5-12% depending on permanganate dose), microcystin removal (with reductions of 91-96%) and a shift of the optimum pH range from 4.3 to 6 without to 5.5-7.3 with pre-oxidation. Degradation of organic matter into inorganic carbon and adsorption of organic matter onto hydrous MnO 2 are suggested as the main processes responsible for coagulation improvement. Moreover, permanganate prevented the formation of Fe-peptide/protein complexes that inhibit coagulation at pH about 6.2 without pre-oxidation. The study showed that carefully optimized dosing of permanganate improves cyanobacterial peptide/protein removal, with the benefit of microcystin elimination. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. SERAPHIN haemodynamic substudy: the effect of the dual endothelin receptor antagonist macitentan on haemodynamic parameters and NT-proBNP levels and their association with disease progression in patients with pulmonary arterial hypertension

    PubMed Central

    Galiè, Nazzareno; Jansa, Pavel; Pulido, Tomás; Channick, Richard N.; Delcroix, Marion; Ghofrani, Hossein-Ardeschir; Le Brun, Franck-Olivier; Mehta, Sanjay; Perchenet, Loïc; Rubin, Lewis J.; Sastry, B.K.S.; Simonneau, Gérald; Sitbon, Olivier; Souza, Rogério; Torbicki, Adam

    2017-01-01

    Aims The effect of macitentan on haemodynamic parameters and NT-proBNP levels was evaluated in pulmonary arterial hypertension (PAH) patients in the SERAPHIN study. Association between these parameters and disease progression, assessed by the primary endpoint (time to first morbidity/mortality event), was explored. Methods and results Of the 742 randomized patients, 187 with right heart catheterization at baseline and month 6 participated in a haemodynamic sub-study. Prespecified endpoints included change from baseline to month 6 in cardiac index (CI), right atrial pressure (RAP), mean pulmonary arterial pressure (mPAP), pulmonary vascular resistance (PVR), mixed-venous oxygen saturation, and NT-proBNP. Exploratory analyses examined associations between CI, RAP, and NT-proBNP and disease progression using the Kaplan-Meier method and Cox regression models. Macitentan improved CI, RAP, mPAP, PVR and NT-proBNP vs. placebo at month 6. Absolute levels of CI, RAP and NT-proBNP at baseline and month 6, but not their changes, were associated with morbidity/mortality events. Patients with CI > 2.5 L/min/m2, RAP < 8 mmHg, or NT-proBNP < 750 fmol/ml at month 6 had a lower risk of morbidity/mortality than those not meeting these thresholds (HR 0.49, 95% CL 0.28–0.86; HR 0.72, 95% CL 0.42–1.22; and HR 0.22, 95% CL 0.15–0.33, respectively). Conclusions For all treatment groups, baseline and month 6 values of CI, RAP, and NT-proBNP, but not their changes, were associated with morbidity/mortality events, confirming their relevance in predicting disease progression in patients with PAH. By improving those parameters, macitentan increased the likelihood of reaching threshold values associated with lower risk of morbidity/mortality. PMID:28329315

  9. SERAPHIN haemodynamic substudy: the effect of the dual endothelin receptor antagonist macitentan on haemodynamic parameters and NT-proBNP levels and their association with disease progression in patients with pulmonary arterial hypertension.

    PubMed

    Galiè, Nazzareno; Jansa, Pavel; Pulido, Tomás; Channick, Richard N; Delcroix, Marion; Ghofrani, Hossein-Ardeschir; Le Brun, Franck-Olivier; Mehta, Sanjay; Perchenet, Loïc; Rubin, Lewis J; Sastry, B K S; Simonneau, Gérald; Sitbon, Olivier; Souza, Rogério; Torbicki, Adam

    2017-04-14

    The effect of macitentan on haemodynamic parameters and NT-proBNP levels was evaluated in pulmonary arterial hypertension (PAH) patients in the SERAPHIN study. Association between these parameters and disease progression, assessed by the primary endpoint (time to first morbidity/mortality event), was explored. Of the 742 randomized patients, 187 with right heart catheterization at baseline and month 6 participated in a haemodynamic sub-study. Prespecified endpoints included change from baseline to month 6 in cardiac index (CI), right atrial pressure (RAP), mean pulmonary arterial pressure (mPAP), pulmonary vascular resistance (PVR), mixed-venous oxygen saturation, and NT-proBNP. Exploratory analyses examined associations between CI, RAP, and NT-proBNP and disease progression using the Kaplan-Meier method and Cox regression models. Macitentan improved CI, RAP, mPAP, PVR and NT-proBNP vs. placebo at month 6. Absolute levels of CI, RAP and NT-proBNP at baseline and month 6, but not their changes, were associated with morbidity/mortality events. Patients with CI > 2.5 L/min/m2, RAP < 8 mmHg, or NT-proBNP < 750 fmol/ml at month 6 had a lower risk of morbidity/mortality than those not meeting these thresholds (HR 0.49, 95% CL 0.28-0.86; HR 0.72, 95% CL 0.42-1.22; and HR 0.22, 95% CL 0.15-0.33, respectively). For all treatment groups, baseline and month 6 values of CI, RAP, and NT-proBNP, but not their changes, were associated with morbidity/mortality events, confirming their relevance in predicting disease progression in patients with PAH. By improving those parameters, macitentan increased the likelihood of reaching threshold values associated with lower risk of morbidity/mortality. © The Author 2017. Published on behalf of the European Society of Cardiology

  10. The Neurostimulation Appropriateness Consensus Committee (NACC): Recommendations on Bleeding and Coagulation Management in Neurostimulation Devices.

    PubMed

    Deer, Timothy R; Narouze, Samer; Provenzano, David A; Pope, Jason E; Falowski, Steven M; Russo, Marc A; Benzon, Honorio; Slavin, Konstantin; Pilitsis, Julie G; Alo, Kenneth; Carlson, Jonathan D; McRoberts, Porter; Lad, Shivanand P; Arle, Jeffrey; Levy, Robert M; Simpson, Brian; Mekhail, Nagy

    2017-01-01

    The Neurostimulation Appropriateness Consensus Committee (NACC) was formed by the International Neuromodulation Society (INS) in 2012 to evaluate the evidence to reduce the risk of complications and improve the efficacy of neurostimulation. The first series of papers, published in 2014, focused on the general principles of appropriate practice in the surgical implantation of neurostimulation devices. The NACC was reconvened in 2014 to address specific patient care issues, including bleeding and coagulation. The INS strives to improve patient care in an evidence-based fashion. The NACC members were appointed or recruited by the INS leadership for diverse expertise, including international clinical expertise in many areas of neurostimulation, evidence evaluation, and publication. The group developed best practices based on peer-reviewed evidence and, in the absence of specific evidence, on expert opinion. Recommendations were based on international evidence in accordance with guideline creation. The NACC has recommended specific measures to reduce the risk of bleeding and neurological injury secondary to impairment of coagulation in the setting of implantable neurostimulation devices in the spine, brain, and periphery. © 2017 International Neuromodulation Society.

  11. Coagulation abnormalities in pediatric and adult patients after sclerotherapy or embolization of vascular anomalies.

    PubMed

    Mason, K P; Neufeld, E J; Karian, V E; Zurakowski, D; Koka, B V; Burrows, P E

    2001-12-01

    The purpose of our study was to examine the coagulation status in patients with vascular anomalies who had undergone sclerotherapy or embolization. Ours was a prospective pilot study of 29 patients who had undergone sclerotherapy or embolization of large vascular anomalies. Fibrinogen, platelet, and d-dimer levels and prothrombin time were obtained before, immediately after, and on the day after the procedure. Five patients with venous malformations had positive d-dimer levels before the procedure. A subgroup analysis revealed a relationship between the type of agent used and the change in coagulation status. Specifically, a positive relationship was found between the use of dehydrated alcohol or sodium tetradecyl sulfate and a disruption in coagulation profiles as evidenced by a decrease in platelets and fibrinogen, an increase in prothrombin time, and a conversion from negative to positive d-dimers. In contrast, sclerotherapy or embolization with cyanoacrylic, polyvinyl alcohol foam particles, or platinum microcoils was not associated with coagulation disturbances. The coagulation disturbances that occur in response to dehydrated alcohol or sodium tetradecyl sulfate sclerotherapy or embolization could compromise the patient's clotting ability. Patients who receive dehydrated alcohol or sodium tetradecyl sulfate during a preoperative sclerotherapy or embolization may experience coagulation disturbances that could increase the risk of bleeding, thrombosis, or hematoma. This patient population may benefit from the use of glue, foam, or coils as a substitute for dehydrated alcohol or sodium tetradecyl sulfate.

  12. Abnormal factor VIII coagulant antigen in patients with renal dysfunction and in those with disseminated intravascular coagulation.

    PubMed Central

    Weinstein, M J; Chute, L E; Schmitt, G W; Hamburger, R H; Bauer, K A; Troll, J H; Janson, P; Deykin, D

    1985-01-01

    Factor VIII antigen (VIII:CAg) exhibits molecular weight heterogeneity in normal plasma. We have compared the relative quantities of VIII:CAg forms present in normal individuals (n = 22) with VIII:CAg forms in renal dysfunction patients (n = 19) and in patients with disseminated intravascular coagulation (DIC; n = 7). In normal plasma, the predominant VIII: CAg form, detectable by sodium dodecyl sulfate polyacrylamide gel electrophoresis, was of molecular weight 2.4 X 10(5), with minor forms ranging from 8 X 10(4) to 2.6 X 10(5) D. A high proportion of VIII:CAg in renal dysfunction patients, in contrast, was of 1 X 10(5) mol wt. The patients' high 1 X 10(5) mol wt VIII: CAg level correlated with increased concentrations of serum creatinine, F1+2 (a polypeptide released upon prothrombin activation), and with von Willebrand factor. Despite the high proportion of the 1 X 10(5) mol wt VIII:CAg form, which suggests VIII:CAg proteolysis, the ratio of Factor VIII coagulant activity to total VIII:CAg concentration was normal in renal dysfunction patients. These results could be simulated in vitro by thrombin treatment of normal plasma, which yielded similar VIII:CAg gel patterns and Factor VIII coagulant activity to antigen ratios. DIC patients with high F1+2 levels but no evidence of renal dysfunction had an VIII:CAg gel pattern distinct from renal dysfunction patients. DIC patients had elevated concentrations of both the 1 X 10(5) and 8 X 10(4) mol wt VIII:CAg forms. We conclude that an increase in a particular VIII:CAg form correlates with the severity of renal dysfunction. The antigen abnormality may be the result of VIII:CAg proteolysis by a thrombinlike enzyme and/or prolonged retention of proteolyzed VIII:CAg fragments. Images PMID:3932466

  13. Minimizing residual aluminum concentration in treated water by tailoring properties of polyaluminum coagulants.

    PubMed

    Kimura, Masaoki; Matsui, Yoshihiko; Kondo, Kenta; Ishikawa, Tairyo B; Matsushita, Taku; Shirasaki, Nobutaka

    2013-04-15

    Aluminum coagulants are widely used in water treatment plants to remove turbidity and dissolved substances. However, because high aluminum concentrations in treated water are associated with increased turbidity and because aluminum exerts undeniable human health effects, its concentration should be controlled in water treatment plants, especially in plants that use aluminum coagulants. In this study, the effect of polyaluminum chloride (PACl) coagulant characteristics on dissolved residual aluminum concentrations after coagulation and filtration was investigated. The dissolved residual aluminum concentrations at a given coagulation pH differed among the PACls tested. Very-high-basicity PACl yielded low dissolved residual aluminum concentrations and higher natural organic matter (NOM) removal. The low residual aluminum concentrations were related to the low content of monomeric aluminum (Ala) in the PACl. Polymeric (Alb)/colloidal (Alc) ratio in PACl did not greatly influence residual aluminum concentration. The presence of sulfate in PACl contributed to lower residual aluminum concentration only when coagulation was performed at around pH 6.5 or lower. At a wide pH range (6.5-8.5), residual aluminum concentrations <0.02 mg/L were attained by tailoring PACl properties (Ala percentage ≤0.5%, basicity ≥85%). The dissolved residual aluminum concentrations did not increase with increasing the dosage of high-basicity PACl, but did increase with increasing the dosage of normal-basicity PACl. We inferred that increasing the basicity of PACl afforded lower dissolved residual aluminum concentrations partly because the high-basicity PACls could have a small percentage of Ala, which tends to form soluble aluminum-NOM complexes with molecular weights of 100 kDa-0.45 μm. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. No effect of isolated long-term supine immobilization or profound prolonged hypoxia on blood coagulation.

    PubMed

    Venemans-Jellema, A; Schreijer, A J M; Le Cessie, S; Emmerich, J; Rosendaal, F R; Cannegieter, S C

    2014-06-01

    Long-distance air travel is associated with an increased risk of venous thrombosis. The most obvious factor that can explain air travel-related thrombosis is prolonged seated immobilization. In addition, hypobaric hypoxia has been shown to affect coagulation, and the lowered atmospheric pressures present in the cabin during the flight may therefore play an etiologic role. Because immobilization and hypoxic conditions are usually present simultaneously in airplanes or hypobaric chambers, their separate effects on the coagulation system or on thrombosis risk have not been studied extensively. To investigate the separate effects of long-term immobilization and profound prolonged hypoxia on blood coagulation. We performed two studies in collaboration with European Space Agency/European Space Research and Technology Centre. In the first study, 24 healthy, non-smoking, adult women underwent 60 days of -6° head-down bed rest. In the second study, we took blood samples from 25 healthy men who participated during their stay in the Concordia station in Antarctica, where, due to the atmospheric conditions, continuous severe hypobaric hypoxia is present. In both studies, we measured markers of blood coagulation at baseline and at several time points during the exposures. We observed no increase in coagulation markers during immobilization or in the hypobaric environment, compared with baseline measurements. Our results indicate that neither immobilization nor hypoxia per se affects blood coagulation. These results implicate that a combination of risk factors is necessary to induce the coagulation system during air travel. © 2014 International Society on Thrombosis and Haemostasis.

  15. Coagulation is more affected by quick than slow bleeding in patients with massive blood loss.

    PubMed

    Zhao, Juan; Yang, Dejuan; Zheng, Dongyou

    2017-03-01

    Profuse blood loss affects blood coagulation to various degrees. However, whether bleeding speed affects coagulation remains uncertain. This study aimed to evaluate the effect of bleeding speed on coagulation function. A total of 141 patients in the Department of Thoracic Surgery of our hospital were evaluated between January 2007 and February 2014. There are two groups of patients, those who received decortication for chronic encapsulated empyema were called the slow-bleeding group, and those who received thoracoscopic upper lobectomy were called the fast bleeding group; each group was further subdivided into three: group A, 1000 ml ≤ bleeding amount < 1500 ml; group B, 1500 ml ≤ bleeding amount < 1700 ml; group C, 1700 ml ≤ bleeding amount < 2000 ml. Then, coagulation function was assessed in all patients before and during surgery and at 1, 2, and 24 h after surgery, measuring prothrombin time, activated partial thromboplastin time (APTT), fibrinogen, blood pressure, hematocrit, hemoglobin, and platelets. Bleeding duration was overtly longer in the slow-bleeding group than that in quick bleeding individuals (2.3 ± 0.25 h vs. 0.41 ± 0.13 h, P < 0.001). Fibrinogen, hematocrit, hemoglobin, and platelets strikingly decreased, whereas prothrombin time and APTT values significantly increased with bleeding amounts in both quick and slow-bleeding groups. Interestingly, compared with slow-bleeding patients, coagulation indices at each time point and bleeding amounts had significant differences in the quick bleeding group.Increased consumption of coagulation factors in quick bleeding may have greater impact on coagulation function.

  16. Pretreatment of palm oil mill effluent (POME) using Moringa oleifera seeds as natural coagulant.

    PubMed

    Bhatia, Subhash; Othman, Zalina; Ahmad, Abdul Latif

    2007-06-25

    Moringa oleifera seeds, an environmental friendly and natural coagulant are reported for the pretreatment of palm oil mill effluent (POME). In coagulation-flocculation process, the M. oleifera seeds after oil extraction (MOAE) are an effective coagulant with the removal of 95% suspended solids and 52.2% reduction in the chemical oxygen demand (COD). The combination of MOAE with flocculant (NALCO 7751), the suspended solids removal increased to 99.3% and COD reduction was 52.5%. The coagulation-flocculation process at the temperature of 30 degrees C resulted in better suspended solids removal and COD reduction compared to the temperature of 40, 55 and 70 degrees C. The MOAE combined with flocculant (NALCO 7751) reduced the sludge volume index (SVI) to 210mL/g with higher recovery of dry mass of sludge (87.25%) and water (50.3%).

  17. Enhancement of Chlorella vulgaris harvesting via the electro-coagulation-flotation (ECF) method.

    PubMed

    Wong, Y K; Ho, Y H; Leung, H M; Ho, K C; Yau, Y H; Yung, K K L

    2017-04-01

    This article explores the potential of using an electro-coagulation-flotation (ECF) harvester to allow flotation of microalgae cells for surface harvesting. A response surface methodology (RSM) model was used to optimize ECF harvesting by adjusting electrode plate material, electrode plate number, charge of the electrodes, electrolyte concentration, and pH value of the culture solution. The result revealed that three aluminum electrode plates (one anode and two cathodes), brine solution (8 g/L), and acidity (pH = 4) of culture solution (optimized ECF harvester) The highest flocculant concentration was measured at 2966 mg/L after 60 min and showed a 79.8 % increase of flocculation concentration. Such results can provide a basis for designing a large-scale microalgae harvester for commercial use in the future.

  18. Coagulation-Fenton coupled treatment for ecotoxicity reduction in highly polluted industrial wastewater.

    PubMed

    Perdigón-Melón, J A; Carbajo, J B; Petre, A L; Rosal, R; García-Calvo, E

    2010-09-15

    A coupled coagulation-Fenton process was applied for the treatment of cosmetic industry effluents. In a first step, FeSO(4) was used as coagulant and the non-precipitated Fe(2+) remaining in dissolution was used as catalyst in the further Fenton process. In the coagulation process a huge decrease in total organic carbon (TOC) was achieved, but the high concentration of phenol derivatives was not diminished. The decrease in TOC in the coagulation step significantly reduces the amount of H(2)O(2) required in the Fenton process for phenol depletion. The coupled process, using a H(2)O(2) dose of only 2 g l(-1), reduced TOC and total phenol to values lower than 40 and 0.10 mg l(-1), respectively. The short reaction period (less than 15 min) in TOC and phenol degradation bodes well for improving treatment in a continuous regime. The combination of both processes significantly reduced the ecotoxicity of raw effluent and markedly increased its biodegradability, thus allowing easier treatment by the conventional biological units in conventional sewage treatment plants (STPs). Copyright 2010 Elsevier B.V. All rights reserved.

  19. Cutting and coagulation during intraoral soft tissue surgery using Er: YAG laser.

    PubMed

    Onisor, I; Pecie, R; Chaskelis, I; Krejci, I

    2013-06-01

    To find the optimal techniques and parameters that enables Er:YAG laser to be used successfully for small intraoral soft tissue interventions, in respect to its cutting and coagulation abilities. In vitro pre-tests: 4 different Er:YAG laser units and one CO2 unit as the control were used for incision and coagulation on porcine lower jaws and optimal parameters were established for each type of intervention and each laser unit: energy, frequency, type, pulse duration and distance. 3 different types of intervention using Er:YAG units are presented: crown lengthening, gingivoplasty and maxillary labial frenectomy with parameters found in the in vitro pre-tests. The results showed a great decrease of the EMG activity of masseter and anterior temporalis muscles. Moreover, the height and width of the chewing cycles in the frontal plane increased after therapy. Er:YAG is able to provide good cutting and coagulation effects on soft tissues. Specific parameters have to be defined for each laser unit in order to obtain the desired effect. Reduced or absent water spray, defocused light beam, local anaesthesia and the most effective use of long pulses are methods to obtain optimal coagulation and bleeding control.

  20. Non-coaxial-based microwave ablation antennas for creating symmetric and asymmetric coagulation zones

    NASA Astrophysics Data System (ADS)

    Mohtashami, Yahya; Luyen, Hung; Hagness, Susan C.; Behdad, Nader

    2018-06-01

    We present an investigation of a new class of microwave ablation (MWA) antennas capable of producing axially symmetric or asymmetric heating patterns. The antenna design is based on a dipole fed by a balanced parallel-wire transmission line. The angle and direction of the deployed dipole arms are used to control the heating pattern. We analyzed the specific absorption rate and temperature profiles using electromagnetic and thermal simulations. Two prototypes were fabricated and tested in ex vivo ablation experiments: one was designed to produce symmetric heating patterns and the other was designed to generate asymmetric heating patterns. Both fabricated prototypes exhibited good impedance matching and produced localized coagulation zones as predicted by the simulations. The prototype operating in porcine muscle created an ˜10 cm3 symmetric ablation zone after 10 min of ablation with a power level of 18 W. The prototype operating in egg white created an ˜4 cm3 asymmetric ablation zone with a directionality ratio of 40% after 5 min of ablation with a power level of 25 W. The proposed MWA antenna design shows promise for minimally invasive treatment of tumors in various clinical scenarios where, depending on the situation, a symmetric or an asymmetric heating pattern may be needed.