Sample records for haemoglobin-based oxygen carriers

  1. Detection of haemoglobins with abnormal oxygen affinity by single blood gas analysis and 2,3-diphosphoglycerate measurement.

    PubMed

    Guerrini, G; Morabito, A; Samaja, M

    2000-10-01

    The aim is to determine if a single measurement of blood 2,3-diphosphoglycerate combined with gas analysis (pH, PCO2, PO2 and saturation) can identify the cause of an altered blood-oxygen affinity: the presence of an abnormal haemoglobin or a red cell disorder. The population (n=94) was divided into healthy controls (A, n=14), carriers of red cell disorders (B, n=72) and carriers of high oxygen affinity haemoglobins (C, n=8). Those variables were measured both in samples equilibrated at selected PCO2 and PO2 and in venous blood. In the univariable approach applied to equilibrated samples, we correctly identified C subjects in 93.6% or 96.8% of the cases depending on the selected variable, the standard P50 (PO2 at which 50% of haemoglobin is oxygenated) or a composite variable calculated from the above measurements. After introducing the haemoglobin concentration as a further discriminating variable, the A and B subjects were correctly identified in 91.9% or 94.2% of the cases, respectively. These figures become 93.0% or 86.1%, and 93.7% or 94.9% of the cases when using direct readings from venous blood, thereby avoiding the blood equilibration step. This test is feasible also in blood samples stored at 4 degrees C for 48 h, or at room temperature for 8 h.

  2. Anaemia: can we define haemoglobin thresholds for impaired oxygen homeostasis and suggest new strategies for treatment?

    PubMed

    Hare, Gregory M T; Tsui, Albert K Y; Ozawa, Sherri; Shander, Aryeh

    2013-03-01

    Observational clinical studies in perioperative medicine have defined a progressive increase in mortality that is proportional to both chronic preoperative anaemia and acute interpretative reductions in haemoglobin concentration (Hb). However, this knowledge has not yet helped to define the critical Hb threshold for organ injury and mortality in specific patient populations or in individual patients. Nor has this knowledge enabled us to develop effective treatment strategies for anaemia, as evident from the lack of a demonstrable improvement in survival in patients randomised to higher Hb levels by various treatment strategies including allogeneic red blood cell transfusion, erythropoiesis-stimulating agents (ESAs) and haemoglobin-based oxygen carriers (HBOCs). These findings emphasise the need for a clearer understanding of the mechanism of anaemia-induced mortality. Towards achieving this goal, experimental studies have defined adaptive mechanism by which oxygen homeostasis is maintained during acute anaemia. The mechanisms include: (1) effective sensing of anaemia-induced tissue hypoxia; (2) adaptive cardiovascular responses to maintain adequate tissue oxygen delivery; (3) heterogeneity of organ-specific oxygen delivery to preferentially sustain vital organs which are essential for acute survival (heart and brain); (4) evidence of increased vital organ injury with interruption of cardiovascular responses to anaemia and (5) evidence of activation of adaptive cellular responses to maintain oxygen homeostasis and support survival during acute anaemia. Understanding these mechanisms may allow us to define treatment thresholds and novel treatment strategies for acute anaemia based on biological markers of tissue hypoxia. The overall goal of these approaches is to improve patient outcomes, including event-free perioperative survival. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Relating oxygen partial pressure, saturation and content: the haemoglobin-oxygen dissociation curve.

    PubMed

    Collins, Julie-Ann; Rudenski, Aram; Gibson, John; Howard, Luke; O'Driscoll, Ronan

    2015-09-01

    The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content), saturation (S O2 ) and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin-oxygen dissociation curve, a graphical representation of the relationship between oxygen satur-ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the S O2 in blood from patients with normal pH and S O2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (S pO2 ) is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (S aO2 ) as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable S pO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.

  4. Reflectance spectroscopy can quantify cutaneous haemoglobin oxygenation by oxygen uptake from the atmosphere after epidermal barrier disruption.

    PubMed

    Heise, H M; Lampen, P; Stücker, M

    2003-11-01

    The supply of oxygen to the viable skin tissue within the upper layers is not only secured by the cutaneous blood vascular system, but to a significant part also by oxygen diffusion from the atmosphere through the horny layer. The aim of this study was to examine whether changes in haemoglobin oxygenation can be observed within the isolated perfused bovine udder skin used as a skin model by removing the upper horny layer by adhesive tape stripping. Diffuse reflectance spectroscopy in the visible spectral range was used for non-invasive characterisation of haemoglobin oxygenation in skin under in vitro conditions. Mid-infrared attenuated total reflectance spectroscopy was employed for analysing the surface layer of the stratum corneum with respect to keratin, water and lipid components. Skin barrier disruption was achieved by repeated stripping of superficial corneocyte layers by adhesive tape. Significant changes in skin haemoglobin oxygenation were observed for skin areas with reduced lipid concentration and a reduced stratum corneum layer, as determined from the quantitative evaluation of the diffuse reflectance skin spectra. The result can be interpreted as an increase of oxygen diffusion after the removal of the upper horny layer.

  5. The effect of 2,3-diphosphoglycerate on the oxygen dissociation curve of human haemoglobin.

    PubMed Central

    Goodford, P J; Norrington, F E; Paterson, R A; Wootton, R

    1977-01-01

    1. Oxygen dissociation curves for concentrated human haemoglobin solutions (1.6 mmol dm-3 in haem) have been measured by mixing known quantities of oxy- and deoxyhaemoglobin solutions and measuring the resulting partial pressure of oxygen with an oxygen electrode. 2. Observations in the presence of 2,3-diphosphoglycerate support previous conclusions derived from experiments at low haemoglobin concentrations, the validity of which has been questioned. 3. The two affinity state model of Monod, Wyman & Changeux (1965) does not fully describe the actions of 2,3-diphosphoglycerate and a model in which this allosteric effector not only binds preferentially to the T state but also lowers the oxygen affinity of this state gives an improved fit to the data. PMID:604451

  6. Hemoglobin extravasation in the brain of rats exchange-transfused with hemoglobin-based oxygen carriers.

    PubMed

    Terraneo, Laura; Bianciardi, Paola; Malavalli, Ashok; Mkrtchyan, Gnel; Spann, Stephanie N; Lohman, Jeff; Samaja, Michele; Vandegriff, Kim D

    2017-06-01

    Haemoglobin (Hb)-based oxygen carriers are under consideration as oxygen therapeutics. Their effect on apoptosis is critical, because the onset of pro-apoptotic pathways may lead to tissue damage. MP4OX, a polyethylene glycol-conjugated human Hb preserves the baseline level of neuron apoptosis with respect to sham. Here we develop a method for measuring Hb extravasation in brain. We exchange transfused rats by haemorrhaging 50% of their blood with simultaneous, isovolemic replacement with Hextend (negative control), MP4OX, or αα-cross-linked Hb. Animals were sacrificed 2 h after transfusion, brain tissue was harvested and processed for double-staining immunofluorescence, whereby Hb ? chain and NeuN (a neuron protein) were stained and quantitated. Whereas Hextend did not induce Hb extravasation, in both MP4OX and ??Hb brains Hb molecules were detected outside neurons. The level of extravasated Hb chains was > 3-fold higher in Hb compared to MP4OX. Western blot analysis revealed that the expression levels of protein related to redox imbalance (e.g., Nrf2, iNOS and ERK phosphorylation) were higher in ααHb than MP4OX. In conclusions, higher Hb extravasation in ααHb than MP4OX induces redox imbalance, which causes higher anti-oxidant response. Whereas Nrf2 response may be considered protective, iNOS response appears damaging.

  7. Photoacoustic imaging of real-time oxygen changes in chronic leg ulcers after topical application of a haemoglobin spray: a pilot study.

    PubMed

    Petri, M; Stoffels, I; Jose, J; Leyh, J; Schulz, A; Dissemond, J; Schadendorf, D; Klode, J

    2016-02-01

    To use a non-invasive measurement of oxygen saturation in chronic leg ulcers after the application of a topical haemoglobin spray to investigate if photoacoustic tomography is able to measure the oxygen saturation and if the stimulated oxygen increase can be demonstrated. We measured the oxygen saturation of the ulcer tissue in five patients with chronic leg ulcers before application and 5 and 20 minutes after application of the haemoglobin spray, using photoacoustic tomography as a new method to assess oxygenation in real-time. The average oxygen saturation showed a significant increase from 56.4% before to 69% (p=0.042) after 5 minutes and 78.8% (p=0.043) 20 minutes after the topical haemoglobin application. The oxygenation status of chronic, hard-to-heal wounds is gaining increasing interest in modern wound therapy. Topical haemoglobin spray is a new and effective method to increase the oxygenation in the ulcer tissue, but until now the link between clinical results and the mode of action was unclear. We were able to show for the first time that the use of a topical haemoglobin spray leads to an increase in oxygen saturation in vivo using photoacoustic tomography. Joachim Dissemond received financial support from the company SastoMed for several scientific projects as well as for lectures and as an advisor. The haemoglobin spray was provided by SastoMed GmbH (Georgsmarienhütte, Germany).

  8. Prospective evaluation of haemoglobin oxygen saturation at rest and after exercise in paediatric sickle cell disease patients

    PubMed Central

    Campbell, Andrew; Minniti, Caterina P.; Nouraie, Mehdi; Arteta, Manuel; Rana, Sohail; Onyekwere, Onyinye; Sable, Craig; Ensing, Gregory; Dham, Niti; Luchtman-Jones, Lori; Kato, Gregory J.; Gladwin, Mark T.; Castro, Oswaldo L.; Gordeuk, Victor R.

    2009-01-01

    Summary Low steady state haemoglobin oxygen saturation in patients with sickle cell anaemia has been associated with the degree of anaemia and haemolysis. How much pulmonary dysfunction contributes to low saturation is not clear. In a prospective study of children and adolescents with sickle cell disease aged 3–20 years at steady state and matched controls, 52% of 391 patients versus 24% of 63 controls had steady state oxygen saturation <99% (P < 0·0001), 9% of patients versus no controls had saturation <95% (P = 0·008) and 8% of patients versus no controls had exercise-induced reduction in saturation ≥3%. Decreasing haemoglobin concentration (P ≤ 0·001) and increasing haemolysis (P ≤ 0·003) but not pulmonary function tests were independent predictors of both lower steady-state saturation and exercise-induced reduction in saturation. Neither history of stroke nor history of acute chest syndrome was significantly associated with lower steady-state oxygen saturation or exercise-induced reduction in saturation. Tricuspid regurgitation velocity was higher in patients with lower steady state haemoglobin oxygen saturation (P = 0·003) and with greater decline in oxygen saturation during the six-minute walk (P = 0·022). In conclusion, lower haemoglobin oxygen saturation is independently associated with increasing degrees of anaemia and haemolysis but not pulmonary function abnormalities among children and adolescents with sickle cell disease. PMID:19694721

  9. Recovery Act: Novel Oxygen Carriers for Coal-fueled Chemical Looping

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, Wei-Ping; Cao, Yan

    2012-11-30

    Chemical Looping Combustion (CLC) could totally negate the necessity of pure oxygen by using oxygen carriers for purification of CO{sub 2} stream during combustion. It splits the single fuel combustion reaction into two linked reactions using oxygen carriers. The two linked reactions are the oxidation of oxygen carriers in the air reactor using air, and the reduction of oxygen carriers in the fuel reactor using fuels (i.e. coal). Generally metal/metal oxides are used as oxygen carriers and operated in a cyclic mode. Chemical looping combustion significantly improves the energy conversion efficiency, in terms of the electricity generation, because it improvesmore » the reversibility of the fuel combustion process through two linked parallel processes, compared to the conventional combustion process, which is operated far away from its thermo-equilibrium. Under the current carbon-constraint environment, it has been a promising carbon capture technology in terms of fuel combustion for power generation. Its disadvantage is that it is less mature in terms of technological commercialization. In this DOE-funded project, accomplishment is made by developing a series of advanced copper-based oxygen carriers, with properties of the higher oxygen-transfer capability, a favorable thermodynamics to generate high purity of CO{sub 2}, the higher reactivity, the attrition-resistance, the thermal stability in red-ox cycles and the achievement of the auto-thermal heat balance. This will be achieved into three phases in three consecutive years. The selected oxygen carriers with final-determined formula were tested in a scaled-up 10kW coal-fueled chemical looping combustion facility. This scaled-up evaluation tests (2-day, 8-hour per day) indicated that, there was no tendency of agglomeration of copper-based oxygen carriers. Only trace-amount of coke or carbon deposits on the copper-based oxygen carriers in the fuel reactor. There was also no evidence to show the sulphidization of

  10. Functionality of albumin-derived perfluorocarbon-based artificial oxygen carriers in the Langendorff-heart †.

    PubMed

    Wrobeln, Anna; Schlüter, Klaus D; Linders, Jürgen; Zähres, Manfred; Mayer, Christian; Kirsch, Michael; Ferenz, Katja B

    2017-06-01

    The aim of this study was to prove whether albumin-derived perfluorocarbon-based nanoparticles (capsules) can operate as a novel artificial oxygen carrier in a rat Langendorff-heart perfusion model. Hearts perfused with capsules showed increased left ventricular pressure and rate pressure product compared to hearts perfused with pure Krebs-Henseleit (KH)-buffer. The capsules prevented the myocardium from functional fail when in their absence a noxious ischemia was observed. Capsules did not change rheological properties of KH-buffer and could repeatedly reload with oxygen. This albumin-derived perfluorocarbon-based artificial oxygen carrier preserved the function of rat hearts due to the transport of oxygen in a satisfactory manner. Because of these positive results, the functionality of the applied capsules should be verified in living animals.

  11. Wyman's equation and oxygen flux through the red cell.

    PubMed

    McCabe, Michael; Maguire, David J

    2007-01-01

    Wyman's equation of 1966 describes the facilitation of flux of a reversibly bound substrate such as oxygen, consequent on the translational diffusion of the binding protein (the carrier). While Wyman's equation, or some modification of it such as that by Murray 2, may provide a realistic description of the flux of oxygen through a dilute solution of haemoglobin (see also Wittenburg), it is unlikely to be the complete explanation, nor even the basis, for oxygen transport through the intact red cell. The mature erythrocyte contains approximately 350 g/l haemoglobin, and while this suggests that only 35% of the available water volume is actually occupied by the protein, the remaining 65% is unavailable for protein translational diffusion due to the mutual exclusion of the haemoglobin molecules. For this reason we have examined other possible mechanisms whereby haemoglobin may facilitate the translational diffusion of oxygen within the erythrocyte. Possible alternatives include rotational diffusion by the haemoglobins, intracellular shuffling of haemoglobins due to shape changes by the erythrocyte, and haemoglobin rotations and oxygen exchange consequent on the charge change which accompanies substration and desubstration of the haemoglobin molecule. Finally the dipole interactions are shown to generate significant intermolecular attractions between adjacent haemoglobins.

  12. A topical haemoglobin spray for oxygenating pressure ulcers: a pilot study.

    PubMed

    Tickle, Joy

    2015-03-01

    The effect of pressure ulcers on patient quality of life have been recognised as a real problem for many years, and the need for robust and effective management of pressure ulcers is now a prominent national health-care issue. Myriad different interventions exist for the treatment of pressure ulcers, including clinically effective dressings and pressure-relieving devices, yet many pressure ulcers still do not heal and often become a chronic wound. This is the second of a series of articles (Norris, 2014) discussing the clinical evaluation of a topical oxygen therapy in practice. It describes a small evaluation involving 18 patients with pressure ulcers. The study set out to determine the effect of a topical oxygen therapy on wound size. The therapy comprises a canister that sprays pure haemoglobin in a water solution into or onto the wound. The haemoglobin spray needs to be used at least once every 3 days, does not require training on its use and can be used in any care setting. Overall, results identified wound healing progression in all 18 wounds and wound size reduction in 17 of the 18 wounds.

  13. Haemoglobin Rahere (beta Lys-Thr): A new high affinity haemoglobin associated with decreased 2, 3-diphosphoglycerate binding and relative polycythaemia.

    PubMed Central

    Lorkin, P A; Stephens, A D; Beard, M E; Wrigley, P F; Adams, L; Lehmann, H

    1975-01-01

    A new haemoglobin with increased oxygen affinity, beta82 (EF6) lysine leads to threonine (Hb Rahere), was found during the investigation of a patient who was found to have a raised haemoglobin concentration after a routine blood count. The substitution affects one of the 2, 3-diphosphoglycerate binding sites, resulting in an increased affinity for oxygen, but both the haem-haem interaction and the alkaline Bohr effect are normal in the haemolysate. This variant had the same mobility as haemoglobin A on electrophoresis at alkaline pH but was detected by measuring the whole blood oxygen affinity; it could be separated from haemoglobin A, however, by electrophoresis in agar at acid pH. The raised haemoglobin concentration was mainly due to a reduction in plasma volume (a relative polycythaemia) and was associated with a persistently raised white blood count. This case emphasises the need to measure the oxygen affinity of haemoglobin in all patients with absolute or relative polycythaemia when some obvious cause is not evident. PMID:124

  14. [Role of hemoglobin affinity to oxygen in adaptation to hypoxemia].

    PubMed

    Kwasiborski, Przemysław Jerzy; Kowalczyk, Paweł; Zieliński, Jakub; Przybylski, Jacek; Cwetsch, Andrzej

    2010-04-01

    One of the basic mechanisms of adapting to hypoxemia is a decrease in the affinity of hemoglobin for oxygen. This process occurs mainly due to the increased synthesis of 2,3-diphosphoglycerate (2,3-DPG) in the erythrocytes, as well as through the Bohr effect. Hemoglobin with decreased affinity for oxygen increases the oxygenation of tissues, because it gives up oxygen more easily during microcirculation. In foetal circulation, however, at a partial oxygen pressure (pO2) of 25 mmHg in the umbilical vein, the oxygen carrier is type F hemoglobin which has a high oxygen affinity. The commonly accepted role for hemoglobin F is limited to facilitating diffusion through the placenta. Is fetal life the only moment when haemoglobin F is useful? THE AIM OF STUDY was to create a mathematical model, which would answer the question at what conditions an increase, rather than a decrease, in haemoglobin oxygen affinity is of benefit to the body. Using the kinetics of dissociation of oxygen from hemoglobin described by the Hill equation as the basis for further discussion, we created a mathematical model describing the pO2 value in the microcirculatory system and its dependence on arterial blood pO2. The calculations were performed for hemoglobin with low oxygen affinity (adult type) and high-affinity hemoglobin (fetal type). The modelling took into account both physiological and pathological ranges of acid-base equilibrium and tissue oxygen extraction parameters. It was shown that for the physiological range of acid-base equilibrium and the resting level of tissue oxygen extraction parameters, with an arterial blood pO2 of 26.8 mmHg, the higher-affinity hemoglobin becomes the more effective oxygen carrier. It was also demonstrated that the arterial blood pO2, below which the high-affinity hemoglobin becomes the more effective carrier, is dependent on blood pH and the difference between the arterial and venous oxygen saturation levels. Simulations performed for the pathological

  15. Syngas production by chemical-looping gasification of wheat straw with Fe-based oxygen carrier.

    PubMed

    Hu, Jianjun; Li, Chong; Guo, Qianhui; Dang, Jiatao; Zhang, Quanguo; Lee, Duu-Jong; Yang, Yunlong

    2018-05-03

    The iron-based oxygen carriers (OC's), Fe 2 O 3 /support (Al 2 O 3 , TiO 2 , SiO 2 and ZrO 2 ), for chemical looping gasification of wheat straw were prepared using impregnation method. The surface morphology, crystal structure, carbon deposition potential, lattice oxygen activity and selectivity of the yielded OCs were examined. The Fe 2 O 3 /Al 2 O 3 OCs at 60% loading has the highest H 2 yield, H 2 /CO ratio, gas yield, and carbon conversion amongst the tested OC's. Parametric studies revealed that an optimal loading Fe 2 O 3 of 60%, steam-to-biomass ratio of 0.8 and oxygen carrier-to-biomass ratio of 1.0 led to the maximum H 2 /CO ratio, gas yield, H 2  + CO ratio, and carbon conversion from the gasified wheat straw. High temperature, up to 950 °C, enhanced the gasification performance. A kinetic network interpreted the noted experimental results. The lattice oxygen provided by the prepared Fe 2 O 3 /Al 2 O 3 oxygen carriers promotes chemical looping gasification efficiencies from wheat straw. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. A comparative analysis of arranging in-flight oxygen aboard commercial air carriers.

    PubMed

    Stoller, J K; Hoisington, E; Auger, G

    1999-04-01

    As air travel has become more commonplace in today's society, so too has air travel by oxygen-using individuals. Because there is little oversight or standardization of in-flight oxygen by the Federal Aviation Administration, individual airlines' policies and practices may vary greatly. On the premise that such variation may cause confusion by prospective air travelers, we undertook the current study to describe individual air carriers' policies and practices and to provide guidance to future air travelers. Data were collected by a series of telephone calls placed by the study investigators to all commercial air carriers listed in the 1997 Cleveland Metropolitan Yellow Pages. The callers were registered respiratory therapists who identified themselves as inexperienced oxygen-requiring travelers wishing to arrange in-flight oxygen for an upcoming trip. Standard questions were asked of each carrier that included the following: Did the carrier have a special "help desk" to assist with oxygen arrangements? What oxygen systems, liter flow options, and interface devices were available? What was the charge for oxygen? How was the charged determined? What documentation from the physician was required? How much notification was required by the airline before the actual flight? In addition to recording these responses, the total amount of time spent on the telephone by the caller was logged along with the number of telephone calls and number of people spoken to in arranging in-flight oxygen. To compare oxygen charges between airlines, we calculated charges based on a "standard trip," which was defined as a nonstop, round-trip lasting 6 h in which the traveler used a flow rate of 2 L/min. Of the 33 commercial air carriers listed in the directory, 11 were US-based carriers and 22 were international-based carriers. Seventy-six percent of the airlines offered in-flight oxygen. For the 25 carriers offering in-flight oxygen, mean phone time required to make the arrangements was 9

  17. Comparison of Iron and Tungsten Based Oxygen Carriers for Hydrogen Production Using Chemical Looping Reforming

    NASA Astrophysics Data System (ADS)

    Khan, M. N.; Shamim, T.

    2017-08-01

    Hydrogen production by using a three reactor chemical looping reforming (TRCLR) technology is an innovative and attractive process. Fossil fuels such as methane are the feedstocks used. This process is similar to a conventional steam-methane reforming but occurs in three steps utilizing an oxygen carrier. As the oxygen carrier plays an important role, its selection should be done carefully. In this study, two oxygen carrier materials of base metal iron (Fe) and tungsten (W) are analysed using a thermodynamic model of a three reactor chemical looping reforming plant in Aspen plus. The results indicate that iron oxide has moderate oxygen carrying capacity and is cheaper since it is abundantly available. In terms of hydrogen production efficiency, tungsten oxide gives 4% better efficiency than iron oxide. While in terms of electrical power efficiency, iron oxide gives 4.6% better results than tungsten oxide. Overall, a TRCLR system with iron oxide is 2.6% more efficient and is cost effective than the TRCLR system with tungsten oxide.

  18. Thermodynamic approach to oxygen delivery in vivo by natural and artificial oxygen carriers.

    PubMed

    Bucci, Enrico

    2009-06-01

    Oxygen is a toxic gas, still indispensable to aerobic life. This paper explores how normal physiology uses the physico-chemical and thermodynamic characteristics of oxygen for transforming a toxic gas into a non toxic indispensable metabolite. Plasma oxygen concentration is in the range of 10(-5) M, insufficient to sustain metabolism. Oxygen carriers, present in blood, release oxygen into plasma, thereby replacing consumed oxygen and buffering PO(2) near their P(50). They are the natural cell-bound carriers, like hemoglobin inside red cells, myoglobin inside myocytes, and artificial cell-free hemoglobin-based oxygen carriers (HBOC) dissolved in plasma. Metabolic oxygen replacement can be defined as cell-bound and cell-free delivery. Cell-bound delivery is retarded by the slow diffusion of oxygen in plasma and interstitial fluids. The 40% hematocrit of normal blood compensates for the delay, coping with the fast oxygen consumption by mitochondria. Facilitated oxygen diffusion by HBOCs corrects for the slow diffusion, making cell-free delivery relatively independent from P(50). At all oxygen affinities, HBOCs produce hyperoxygenations that are compensated by vasoconstrictions. There is a strict direct correlation between the rate of oxygen replacement and hemoglobin content of blood. The free energy loss of the gradient adds a relevant regulation of tissues oxygenation. Oxygen is retained intravascularly by the limited permeability to gases of vessel walls.

  19. A Bovine Hemoglobin-Based Oxygen Carrier as Pump Prime for Cardiopulmonary Bypass: Reduced Systemic Lactic Acidosis and Improved Cerebral Oxygen Metabolism During Low-flow in a Porcine Model

    DTIC Science & Technology

    2010-11-10

    1 A bovine hemoglobin-based oxygen carrier as pump prime for cardiopulmonary bypass: reduced systemic lactic acidosis and improved cerebral...2010 2. REPORT TYPE Final Report 3. DATES COVERED (From - To) June 2007 - November 2010 4. TITLE AND SUBTITLE A bovine hemoglobin-based oxygen...carrier as pump prime for cardiopulmonary bypass: reduced systemic lactic acidosis and improved cerebral oxygen metabolism during low-flow in a

  20. [Role of erythrocyte cytoplasmic structures in changes in the affinity of haemoglobin for oxygen].

    PubMed

    Bryzgalova, N Iu; Brazhe, N A; Iusipovich, A U; Maksimov, G V; Rubin, A B

    2009-01-01

    Changes in the refractive index of the cytoplasm and the affinity of haemoporphyrin of erythrocyte haemoglobin to oxygen (pH, 2,3-diphosphoglycerate) have been investigated using laser interference microscopy and Raman spectroscopy. It has been established that a decrease in pH and an increase in the content of 2,3-diphosphoglycerate are accompanied by changes in both the form of the cell and the refractive index of the cytoplasm and the affinity of haemoporphyrin of hemoglobin to oxygen. It has been shown that as pH is reduced, the capacity of haemoporphyrin for binding oxygen decreases and as the concentration of 2,3-diphosphoglycerate is increased, the ability of haemoporphyrin for oxygen reabsorption increases.

  1. Purification, crystallization and preliminary crystallographic study of low oxygen-affinity haemoglobin from cat (Felis silvestris catus) in two different crystal forms.

    PubMed

    Balasubramanian, M; Moorthy, Pon Sathya; Neelagandan, K; Ponnuswamy, M N

    2009-03-01

    Haemoglobin is a metalloprotein which plays a major role in the transportation of oxygen from the lungs to tissues and of carbon dioxide back to the lungs. The present work reports the preliminary crystallographic study of low oxygen-affinity haemoglobin from cat in different crystal forms. Cat blood was collected, purified by anion-exchange chromatography and crystallized in two different conditions by the hanging-drop vapour-diffusion method under unbuffered low-salt and buffered high-salt concentrations using PEG 3350 as a precipitant. Intensity data were collected using MAR345 and MAR345dtb image-plate detector systems. Cat haemoglobin crystallizes in monoclinic and orthorhombic crystal forms with one and two whole biological molecules (alpha(2)beta(2)), respectively, in the asymmetric unit.

  2. Effect of hemoglobin- and Perflubron-based oxygen carriers on common clinical laboratory tests.

    PubMed

    Ma, Z; Monk, T G; Goodnough, L T; McClellan, A; Gawryl, M; Clark, T; Moreira, P; Keipert, P E; Scott, M G

    1997-09-01

    Polymerized hemoglobin solutions (Hb-based oxygen carriers; HBOCs) and a second-generation perfluorocarbon (PFC) emulsion (Perflubron) are in clinical trials as temporary oxygen carriers ("blood substitutes"). Plasma and serum samples from patients receiving HBOCs look markedly red, whereas those from patients receiving PFC appear to be lipemic. Because hemolysis and lipemia are well-known interferents in many assays, we examined the effects of these substances on clinical chemistry, immunoassay, therapeutic drug, and coagulation tests. HBOC concentrations up to 50 g/L caused essentially no interference for Na, K, Cl, urea, total CO2, P, uric acid, Mg, creatinine, and glucose values determined by the Hitachi 747 or Vitros 750 analyzers (or both) or for immunoassays of lidocaine, N-acetylprocainamide, procainamide, digoxin, phenytoin, quinidine, or theophylline performed on the Abbott AxSym or TDx. Gentamycin and vancomycin assays on the AxSym exhibited a significant positive and negative interference, respectively. Immunoassays for TSH on the Abbott IMx and for troponin I on the Dade Stratus were unaffected by HBOC at this concentration. Tests for total protein, albumin, LDH, AST, ALT, GGT, amylase, lipase, and cholesterol were significantly affected to various extents at different HBOC concentrations on the Hitachi 747 and Vitros 750. The CK-MB assay on the Stratus exhibited a negative interference at 5 g/L HBOC. HBOC interference in coagulation tests was method-dependent-fibrometer-based methods on the BBL Fibro System were free from interference, but optical-based methods on the MLA 1000C exhibited interferences at 20 g/L HBOC. A 1:20 dilution of the PFC-based oxygen carrier (600 g/L) caused no interference on any of these chemistry or immunoassay tests except for amylase and ammonia on the Vitros 750 and plasma iron on the Hitachi 747.

  3. Numerical investigation of oxygen transport by hemoglobin-based carriers through microvessels.

    PubMed

    Hyakutake, Toru; Kishimoto, Takumi

    2017-12-01

    The small size of hemoglobin-based oxygen carriers (HBOCs) may expand the realm of new treatment possibilities for various circulatory diseases. The parametric evaluation of HBOC performance for oxygen transport within tissue is essential for effectively characterizing its performance for each circulatory disease assessed. Thus, the overarching objective of this present study was to numerically investigate the reaction-diffusion phenomenon of oxygenated HBOCs and oxygen on tissues through microvessels. We considered dissociation rate coefficients, oxygen affinity, and diffusion coefficients due to Brownian motion as the biophysical parameters for estimating HBOC performance for oxygen transport. A two-dimensional computational domain, including vessel and tissue regions, was, therefore, accordingly assumed. It was observed that HBOC flows in a microvessel with a diameter of 25 μm and a length of 1 mm, and that the dissociated oxygen diffuses to the tissue region. The results indicated that oxyhemoglobin saturation and partial oxygen tension in a downstream region changed according to each biophysical parameter of HBOC. Moreover, the change in oxygen consumption rate in the tissue region had considerable influence on the oxyhemoglobin saturation level within the vessel. Comparison between simulation results and existing in vitro experimental data of actual HBOCs and RBC showed qualitatively good agreement. These results provide important information for the effective design of robust HBOCs in future.

  4. Total haemoglobin mass, but not haemoglobin concentration, is associated with preoperative cardiopulmonary exercise testing-derived oxygen-consumption variables.

    PubMed

    Otto, J M; Plumb, J O M; Wakeham, D; Clissold, E; Loughney, L; Schmidt, W; Montgomery, H E; Grocott, M P W; Richards, T

    2017-05-01

    Cardiopulmonary exercise testing (CPET) measures peak exertional oxygen consumption ( V˙O2peak ) and that at the anaerobic threshold ( V˙O2 at AT, i.e. the point at which anaerobic metabolism contributes substantially to overall metabolism). Lower values are associated with excess postoperative morbidity and mortality. A reduced haemoglobin concentration ([Hb]) results from a reduction in total haemoglobin mass (tHb-mass) or an increase in plasma volume. Thus, tHb-mass might be a more useful measure of oxygen-carrying capacity and might correlate better with CPET-derived fitness measures in preoperative patients than does circulating [Hb]. Before major elective surgery, CPET was performed, and both tHb-mass (optimized carbon monoxide rebreathing method) and circulating [Hb] were determined. In 42 patients (83% male), [Hb] was unrelated to V˙O2 at AT and V˙O2peak ( r =0.02, P =0.89 and r =0.04, P =0.80, respectively) and explained none of the variance in either measure. In contrast, tHb-mass was related to both ( r =0.661, P <0.0001 and r =0.483, P =0.001 for V˙O2 at AT and V˙O2peak , respectively). The tHb-mass explained 44% of variance in V˙O2 at AT ( P <0.0001) and 23% in V˙O2peak ( P =0.001). In contrast to [Hb], tHb-mass is an important determinant of physical fitness before major elective surgery. Further studies should determine whether low tHb-mass is predictive of poor outcome and whether targeted increases in tHb-mass might thus improve outcome. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  5. Numerical simulation of oxygen delivery to muscle tissue in the presence of hemoglobin-based oxygen carriers.

    PubMed

    Patton, Jaqunda N; Palmer, Andre F

    2006-01-01

    This work represents a culmination of research on oxygen transport to muscle tissue, which takes into account oxygen transport due to convection, diffusion, and the kinetics of simultaneous reactions between oxygen and hemoglobin and myoglobin. The effect of adding hemoglobin-based oxygen carriers (HBOCs) to the plasma layer of blood in a single capillary surrounded by muscle tissue based on the geometry of the Krogh tissue cylinder is examined for a range of HBOC oxygen affinity, HBOC concentration, capillary inlet oxygen tension (pO(2)), and hematocrit. The full capillary length of the hamster retractor muscle was modeled under resting (V(max) = 1.57 x 10(-4) mLO(2) mL(-1) s(-1), cell velocity (v(c)) = 0.015 cm/s) and working (V(max) = 1.57 x 10(-3) mLO(2) mL(-1) s(-1), v(c) = 0.075 cm/s) conditions. Two spacings between the red blood cell (RBC) and the capillary wall were examined, corresponding to a capillary with and without an endothelial surface layer. Simulations led to the following conclusions, which lend physiological insight into oxygen transport to muscle tissue in the presence of HBOCs: (1) The reaction kinetics between oxygen and myoglobin in the tissue region, oxygen and HBOCs in the plasma, and oxygen and RBCs in the capillary lumen should not be neglected. (2) Simulation results yielded new insight into possible mechanisms of oxygen transport in the presence of HBOCs. (3) HBOCs may act as a source or sink for oxygen in the capillary and may compete with RBCs for oxygen. (4) HBOCs return oxygen delivery to muscle tissue to normal for varying degrees of hypoxia (inlet capillary pO(2) < 30 mmHg) and anemia (hematocrit < 46%) for the hamster model.

  6. Purification, crystallization and preliminary crystallographic study of haemoglobin from camel (Camelus dromedarius): a high oxygen-affinity lowland species.

    PubMed

    Balasubramanian, M; Moorthy, Pon Sathya; Neelagandan, K; Ponnuswamy, M N

    2009-08-01

    Haemoglobin is a prototypical allosteric protein that is mainly involved in the transportation of oxygen from the lungs to tissues and of carbon dioxide back to the lungs in an intrinsically coordinated manner to maintain the viability of cells. Haemoglobin from Camelus dromedarius provides an interesting case study of adaptation to life in deserts at extremely high temperatures. An ambition to unravel the integrated structural and functional aspects of the casual survival of this animal at high temperatures led us to specifically work on this problem. The present work reports the preliminary crystallographic study of camel haemoglobin. Camel blood was collected and the haemoglobin was purified by anion-exchange chromatography and crystallized using the hanging-drop vapour-diffusion method under buffered high salt concentration using PEG 3350 as a precipitant. Intensity data were collected using a MAR 345 dtb image-plate detector system. Camel haemoglobin crystallized in the monoclinic space group P2(1), with one whole biological molecule (alpha(2)beta(2)) in the asymmetric unit and unit-cell parameters a = 52.759, b = 116.782, c = 52.807 A, beta = 120.07 degrees .

  7. Albumin-derived perfluorocarbon-based artificial oxygen carriers: A physico-chemical characterization and first in vivo evaluation of biocompatibility.

    PubMed

    Wrobeln, Anna; Laudien, Julia; Groß-Heitfeld, Christoph; Linders, Jürgen; Mayer, Christian; Wilde, Benjamin; Knoll, Tanja; Naglav, Dominik; Kirsch, Michael; Ferenz, Katja B

    2017-06-01

    Until today, artificial oxygen carriers have not been reached satisfactory quality for routine clinical treatments. To bridge this gap, we designed albumin-derived perfluorocarbon-based nanoparticles as novel artificial oxygen carriers and evaluated their physico-chemical and pharmacological performance. Our albumin-derived perfluorocarbon-based nanoparticles (capsules), composed of an albumin shell and a perfluorodecalin core, were synthesized using ultrasonics. Their subsequent analysis by physico-chemical methods such as scanning electron-, laser scanning- and dark field microscopy as well as dynamic light scattering revealed spherically-shaped, nano-sized particles, that were colloidally stable when dispersed in 5% human serum albumin solution. Furthermore, they provided a remarkable maximum oxygen capacity, determined with a respirometer, reflecting a higher oxygen transport capacity than the competitor Perftoran®. Intravenous administration to healthy rats was well tolerated. Undesirable effects on either mean arterial blood pressure, hepatic microcirculation (determined by in vivo microscopy) or any deposit of capsules in organs, except the spleen, were not observed. Some minor, dose-dependent effects on tissue damage (release of cellular enzymes, alterations of spleen's micro-architecture) were detected. As our promising albumin-derived perfluorocarbon-based nanoparticles fulfilled decisive physico-chemical demands of an artificial oxygen carrier while lacking severe side-effects after in vivo administration they should be advanced to functionally focused in vivo testing conditions. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. A computational model of oxygen delivery by hemoglobin-based oxygen carriers in three-dimensional microvascular networks.

    PubMed

    Tsoukias, Nikolaos M; Goldman, Daniel; Vadapalli, Arjun; Pittman, Roland N; Popel, Aleksander S

    2007-10-21

    A detailed computational model is developed to simulate oxygen transport from a three-dimensional (3D) microvascular network to the surrounding tissue in the presence of hemoglobin-based oxygen carriers. The model accounts for nonlinear O(2) consumption, myoglobin-facilitated diffusion and nonlinear oxyhemoglobin dissociation in the RBCs and plasma. It also includes a detailed description of intravascular resistance to O(2) transport and is capable of incorporating realistic 3D microvascular network geometries. Simulations in this study were performed using a computer-generated microvascular architecture that mimics morphometric parameters for the hamster cheek pouch retractor muscle. Theoretical results are presented next to corresponding experimental data. Phosphorescence quenching microscopy provided PO(2) measurements at the arteriolar and venular ends of capillaries in the hamster retractor muscle before and after isovolemic hemodilution with three different hemodilutents: a non-oxygen-carrying plasma expander and two hemoglobin solutions with different oxygen affinities. Sample results in a microvascular network show an enhancement of diffusive shunting between arterioles, venules and capillaries and a decrease in hemoglobin's effectiveness for tissue oxygenation when its affinity for O(2) is decreased. Model simulations suggest that microvascular network anatomy can affect the optimal hemoglobin affinity for reducing tissue hypoxia. O(2) transport simulations in realistic representations of microvascular networks should provide a theoretical framework for choosing optimal parameter values in the development of hemoglobin-based blood substitutes.

  9. Tri-metallic ferrite oxygen carriers for chemical looping combustion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siriwardane, Ranjani V.; Fan, Yueying

    The disclosure provides a tri-metallic ferrite oxygen carrier for the chemical looping combustion of carbonaceous fuels. The tri-metallic ferrite oxygen carrier comprises Cu.sub.xFe.sub.yMn.sub.zO.sub.4-.delta., where Cu.sub.xFe.sub.yMn.sub.zO.sub.4-.delta. is a chemical composition. Generally, 0.5.ltoreq.x.ltoreq.2.0, 0.2.ltoreq.y.ltoreq.2.5, and 0.2.ltoreq.z.ltoreq.2.5, and in some embodiments, 0.8.ltoreq.x.ltoreq.1.2, y.ltoreq.1.2, and z.gtoreq.0.8. The tri-metallic ferrite oxygen carrier may be used in various applications for the combustion of carbonaceous fuels, including as an oxygen carrier for chemical looping combustion.

  10. Comparative In Vivo Effects of Hemoglobin-Based Oxygen Carriers (HBOC) with Varying Prooxidant and Physiological Reactivity.

    PubMed

    Toma, Vlad Al; Farcaș, Anca D; Roman, Ioana; Sevastre, Bogdan; Hathazi, Denisa; Scurtu, Florina; Damian, Grigore; Silaghi-Dumitrescu, Radu

    2016-01-01

    A series of hemoglobin-based oxygen carrier candidates (HBOC), previously noted for their differences in prooxidative and physiological reactivity, were compared in terms of the negative effects displayed upon injection in Wistar rats. At the concentrations tested, antioxidant strategies based on albumin as well as based on rubrerythrin appear to offer observable physiological advantages.

  11. Development of Recombinant Hemoglobin-Based Oxygen Carriers

    PubMed Central

    Varnado, Cornelius L.; Mollan, Todd L.; Birukou, Ivan; Smith, Bryan J.Z.; Henderson, Douglas P.

    2013-01-01

    Abstract Significance: The worldwide blood shortage has generated a significant demand for alternatives to whole blood and packed red blood cells for use in transfusion therapy. One such alternative involves the use of acellular recombinant hemoglobin (Hb) as an oxygen carrier. Recent Advances: Large amounts of recombinant human Hb can be expressed and purified from transgenic Escherichia coli. The physiological suitability of this material can be enhanced using protein-engineering strategies to address specific efficacy and toxicity issues. Mutagenesis of Hb can (i) adjust dioxygen affinity over a 100-fold range, (ii) reduce nitric oxide (NO) scavenging over 30-fold without compromising dioxygen binding, (iii) slow the rate of autooxidation, (iv) slow the rate of hemin loss, (v) impede subunit dissociation, and (vi) diminish irreversible subunit denaturation. Recombinant Hb production is potentially unlimited and readily subjected to current good manufacturing practices, but may be restricted by cost. Acellular Hb-based O2 carriers have superior shelf-life compared to red blood cells, are universally compatible, and provide an alternative for patients for whom no other alternative blood products are available or acceptable. Critical Issues: Remaining objectives include increasing Hb stability, mitigating iron-catalyzed and iron-centered oxidative reactivity, lowering the rate of hemin loss, and lowering the costs of expression and purification. Although many mutations and chemical modifications have been proposed to address these issues, the precise ensemble of mutations has not yet been identified. Future Directions: Future studies are aimed at selecting various combinations of mutations that can reduce NO scavenging, autooxidation, oxidative degradation, and denaturation without compromising O2 delivery, and then investigating their suitability and safety in vivo. Antioxid. Redox Signal. 18, 2314–2328. PMID:23025383

  12. Variation of haemoglobin extinction coefficients can cause errors in the determination of haemoglobin concentration measured by near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Kim, J. G.; Liu, H.

    2007-10-01

    Near-infrared spectroscopy or imaging has been extensively applied to various biomedical applications since it can detect the concentrations of oxyhaemoglobin (HbO2), deoxyhaemoglobin (Hb) and total haemoglobin (Hbtotal) from deep tissues. To quantify concentrations of these haemoglobin derivatives, the extinction coefficient values of HbO2 and Hb have to be employed. However, it was not well recognized among researchers that small differences in extinction coefficients could cause significant errors in quantifying the concentrations of haemoglobin derivatives. In this study, we derived equations to estimate errors of haemoglobin derivatives caused by the variation of haemoglobin extinction coefficients. To prove our error analysis, we performed experiments using liquid-tissue phantoms containing 1% Intralipid in a phosphate-buffered saline solution. The gas intervention of pure oxygen was given in the solution to examine the oxygenation changes in the phantom, and 3 mL of human blood was added twice to show the changes in [Hbtotal]. The error calculation has shown that even a small variation (0.01 cm-1 mM-1) in extinction coefficients can produce appreciable relative errors in quantification of Δ[HbO2], Δ[Hb] and Δ[Hbtotal]. We have also observed that the error of Δ[Hbtotal] is not always larger than those of Δ[HbO2] and Δ[Hb]. This study concludes that we need to be aware of any variation in haemoglobin extinction coefficients, which could result from changes in temperature, and to utilize corresponding animal's haemoglobin extinction coefficients for the animal experiments, in order to obtain more accurate values of Δ[HbO2], Δ[Hb] and Δ[Hbtotal] from in vivo tissue measurements.

  13. Particulate Formation from a Copper Oxide-Based Oxygen Carrier in Chemical Looping Combustion for CO2 Capture

    EPA Science Inventory

    Attrition behavior and particle loss of a copper oxide-based oxygen carrier from a methane chemical looping combustion (CLC) process was investigated in a fluidized bed reactor. The aerodynamic diameters of most elutriated particulates, after passing through a horizontal settling...

  14. Purification, crystallization and preliminary X-ray analysis of haemoglobin from ostrich (Struthio camelus).

    PubMed

    Sundaresan, S S; Ramesh, P; Sivakumar, K; Ponnuswamy, M N

    2009-07-01

    Haemoglobin is a tetrameric protein that carries oxygen from the lungs to tissues and carbon dioxide from tissues back to the lungs. The oxygen-binding properties of haemoglobin are regulated through the binding of allosteric effectors. The respiratory system of avian species is unique and complex in nature when compared with that of mammals. In avian species, inositol pentaphosphate (inositol-P(5)) is present in the erythrocytes of the adult and is thought to be the major factor responsible for the relatively high oxygen affinity of the whole blood. The ostrich (Struthio camelus) is a large flightless bird which contains inositol tetrakisphosphate (inositol-P(4)) in its erythrocytes and its whole blood oxygen affinity is higher. Efforts have been made to explore the structure-function relationship of ostrich haemoglobin. Ostrich haemoglobin was purified using ion-exchange chromatography. Haemoglobin crystals were grown by the hanging-drop vapour-diffusion method using PEG 3350 as the precipitant in 50 mM phosphate buffer pH 7.2. Data were collected using a MAR345 image-plate detector system. The crystals of ostrich haemoglobin diffracted to 2.2 A resolution. They belonged to the orthorhombic space group P2(1)2(1)2(1) with one whole biological molecule in the asymmetric unit; the unit-cell parameters were a = 80.93, b = 81.68, c = 102.05 A.

  15. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration.

    PubMed

    Laufer, Jan; Delpy, Dave; Elwell, Clare; Beard, Paul

    2007-01-07

    A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO(2)) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO(2)) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO(2) and HHb, total haemoglobin concentration and SO(2). The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of +/-3.8 g l(-1) (+/-58

  16. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration

    NASA Astrophysics Data System (ADS)

    Laufer, Jan; Delpy, Dave; Elwell, Clare; Beard, Paul

    2007-01-01

    A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO2) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO2) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO2 and HHb, total haemoglobin concentration and SO2. The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of ±3.8 g l-1 (±58 µM) and ±4

  17. [Peroxynitrite effect on the haemoglobin oxygen affinity in vitro in presence of different partial pressure of carbon dioxide].

    PubMed

    Stepuro, T L; Zinchuk, V V

    2011-08-01

    Peroxynitrite (ONOO-) besides its toxic possesses regulatory action that includes the modulation of oxygen binding properties of blood. The aim of this work was to estimate ONOO- effect on the haemoglobin oxygen affinity (HOA) in vitro in presence of different partial pressure of carbon dioxide (CO2). The ONOO- presence in venous blood in conditions of hypercapnia induced oxyhaemoglobin dissociation curve shift leftward while in hypocapnic conditions the result of a different character was obtained. The revealed effect of ONOO- is realized, possibly, through various modifications ofhaemoglobin whose formation is dependent on the CO2 pressure. The ONOO- influences the HOA in different manner that can be important in regulation of blood oxygenation in lungs and maintenance of oxygen consumption in tissues.

  18. Haemoglobin variants among voluntary blood donors in Jos, Nigeria: the implications on blood transfusion.

    PubMed

    Damulak, O D; Bolorunduro, S A; Egesie, J O; Yakubu, K; Godit, P; Smith, O A

    2013-01-01

    The normal haemoglobin is an efficient transporter of oxygen to the tissues and carbondioxide from tissues to the lungs for elimination. Various abnormal haemoglobin variants including, the sickle cell diseases, have been described with varying sickling tendencies. This study aimed to determine the haemoglobin variants among voluntary blood donors in Jos. Records of the age, sex, Haemoglobin level, and the haemoglobin genotype of all voluntary blood donors who donated blood at the National Blood Transfusion Service Centre, Jos, Nigeria between January 2011 and April 2012; and their haemoglobin levels and protein electrophoresis determined, were reviewed. A total of 937 blood donors, 658 (70.23%) males and 279 (29.79%) females, mean age 32.4 years, donated blood voluntarily, their haemoglobin electrophoretic patterns determined by alkaline cellulose acetate electrophoresis. Donor blood haemoglobin levels were determined by automation. Haemoglobin protein electrophoretic patterns identified among our donors were 77.70% AA, 21.88% AS, 0.22% SC, 0.11% AC and 0.11% SS. Mean haemoglobin levels of the donors according to their haemoglobin proteins electrophoretic patterns were, 150.4 +/- 12.5 gms/l for AA, 151.9 +/- 13.8 gms/l for AS and 131.1 +/- 5.0 gms/l for haemoglobin SC. Determination of haemoglobin protein electrophoretic patterns of blood unit for transfusion could enhance selective blood issuing based on recipient's haemoglobin type.

  19. Performance of nickel-based oxygen carrier produced using renewable fuel aloe vera

    NASA Astrophysics Data System (ADS)

    Afandi, NF; Devaraj, D.; Manap, A.; Ibrahim, N.

    2017-04-01

    Consuming and burning of fuel mainly fossil fuel has gradually increased in this upcoming era due to high-energy demand and causes the global warming. One of the most effective ways to reduce the greenhouse gases is by capturing carbon dioxide (CO2) during the combustion process. Chemical looping combustion (CLC) is one of the most effective methods to capture the CO2 without the need of an energy intensive air separation unit. This method uses oxygen carrier to provide O2 that can react with fuel to form CO2 and H2O. This research focuses on synthesizing NiO/NiAl2O4 as an oxygen carrier due to its properties that can withstand high temperature during CLC application. The NiO/NiAl2O4 powder was synthesized using solution combustion method with plant extract renewable fuel, aloe vera as the fuel. In order to optimize the performance of the particles that can be used in CLC application, various calcination temperatures were varied at 600°C, 800°C, 1050°C and 1300°C. The phase and morphology of obtained powders were characterized using X-ray diffraction (XRD) and Field Emission Microscopy (FESEM) respectively together with the powder elements. In CLC application, high reactivity can be achieved by using smaller particle size of oxygen carrier. This research succeeded in producing nano-structured powder with high crystalline structure at temperature 1050°C which is suitable to be used in CLC application.

  20. Method of measuring blood oxygenation based on spectroscopy of diffusely scattered light

    NASA Astrophysics Data System (ADS)

    Kleshnin, M. S.; Orlova, A. G.; Kirillin, M. Yu.; Golubyatnikov, G. Yu.; Turchin, I. V.

    2017-05-01

    A new approach to the measurement of blood oxygenation is developed and implemented, based on an original two-step algorithm reconstructing the relative concentration of biological chromophores (haemoglobin, water, lipids) from the measured spectra of diffusely scattered light at different distances from the radiation source. The numerical experiments and approbation of the proposed approach using a biological phantom have shown the high accuracy of the reconstruction of optical properties of the object in question, as well as the possibility of correct calculation of the haemoglobin oxygenation in the presence of additive noises without calibration of the measuring device. The results of the experimental studies in animals agree with the previously published results obtained by other research groups and demonstrate the possibility of applying the developed method to the monitoring of blood oxygenation in tumour tissues.

  1. A quantitative analysis of the effects of 2,3-diphosphoglycerate, adenosine triphosphate and inositol hexaphosphate on the oxygen dissociation curve of human haemoglobin.

    PubMed Central

    Goodford, P J; St-Louis, J; Wootton, R

    1978-01-01

    1. Oxygen dissociation curves have been measured for human haemoglobin solutions with different concentrations of the allosteric effectors 2,3-diphosphoglycerate, adenosine triphosphate and inositol hexaphosphate. 2. Each effector produces a concentration dependent right shift of the oxygen dissociation curve, but a point is reached where the shift is maximal and increasing the effector concentration has no further effect. 3. Mathematical models based on the Monod, Wyman & Changeux (1965) treatment of allosteric proteins have been fitted to the data. For each compound the simple two-state model and its extension to take account of subunit inequivalence were shown to be inadequate, and a better fit was obtained by allowing the effector to lower the oxygen affinity of the deoxy conformational state as well as binding preferentially to this conformation. PMID:722582

  2. Chemical Looping Technology: Oxygen Carrier Characteristics.

    PubMed

    Luo, Siwei; Zeng, Liang; Fan, Liang-Shih

    2015-01-01

    Chemical looping processes are characterized as promising carbonaceous fuel conversion technologies with the advantages of manageable CO2 capture and high energy conversion efficiency. Depending on the chemical looping reaction products generated, chemical looping technologies generally can be grouped into two types: chemical looping full oxidation (CLFO) and chemical looping partial oxidation (CLPO). In CLFO, carbonaceous fuels are fully oxidized to CO2 and H2O, as typically represented by chemical looping combustion with electricity as the primary product. In CLPO, however, carbonaceous fuels are partially oxidized, as typically represented by chemical looping gasification with syngas or hydrogen as the primary product. Both CLFO and CLPO share similar operational features; however, the optimum process configurations and the specific oxygen carriers used between them can vary significantly. Progress in both CLFO and CLPO is reviewed and analyzed with specific focus on oxygen carrier developments that characterize these technologies.

  3. Structural and Functional Characterization of a New Double Variant Haemoglobin (HbG-Philadelphia/Duarte α(2)β(2)).

    PubMed

    Fais, Antonella; Casu, Mariano; Ruggerone, Paolo; Ceccarelli, Matteo; Porcu, Simona; Era, Benedetta; Anedda, Roberto; Sollaino, Maria Carla; Galanello, Renzo; Corda, Marcella

    2011-01-01

    WE REPORT THE FIRST CASE OF COSEGREGATION OF TWO HAEMOGLOBINS (HBS): HbG-Philadelphia [α68(E17)Asn → Lys] and HbDuarte [β62(E6)Ala → Pro]. The proband is a young patient heterozygous also for β°-thalassaemia. We detected exclusively two haemoglobin variants: HbDuarte and HbG-Philadelphia/Duarte. Functional study of the new double variant HbG-Philadelphia/Duarte exhibited an increase in oxygen affinity, with a slight decrease of cooperativity and Bohr effect. This functional behaviour is attributed to β62Ala → Pro instead of α68Asn → Lys substitution. Indeed, HbG-Philadelphia isolated in our laboratory from blood cells donor carrier for this variant is not affected by any functional modification, whereas purified Hb Duarte showed functional properties very similar to the double variant. NMR and MD simulation studies confirmed that the presence of Pro instead of Ala at the β62 position produces displacement of the E helix and modifications of the tertiary structure. The substitution α68(E17)Asn → Lys does not cause significant structural and dynamical modifications of the protein. A possible structure-based rational of substitution effects is suggested.

  4. Metal ferrite oxygen carriers for chemical looping combustion of solid fuels

    DOEpatents

    Siriwardane, Ranjani V.; Fan, Yueying

    2017-01-31

    The disclosure provides a metal ferrite oxygen carrier for the chemical looping combustion of solid carbonaceous fuels, such as coal, coke, coal and biomass char, and the like. The metal ferrite oxygen carrier comprises MFe.sub.xO.sub.y on an inert support, where MFe.sub.xO.sub.y is a chemical composition and M is one of Mg, Ca, Sr, Ba, Co, Mn, and combinations thereof. For example, MFe.sub.xO.sub.y may be one of MgFe.sub.2O.sub.4, CaFe.sub.2O.sub.4, SrFe.sub.2O.sub.4, BaFe.sub.2O.sub.4, CoFe.sub.2O.sub.4, MnFeO.sub.3, and combinations thereof. The MFe.sub.xO.sub.y is supported on an inert support. The inert support disperses the MFe.sub.xO.sub.y oxides to avoid agglomeration and improve performance stability. In an embodiment, the inert support comprises from about 5 wt. % to about 60 wt. % of the metal ferrite oxygen carrier and the MFe.sub.xO.sub.y comprises at least 30 wt. % of the metal ferrite oxygen carrier. The metal ferrite oxygen carriers disclosed display improved reduction rates over Fe.sub.2O.sub.3, and improved oxidation rates over CuO.

  5. Fabrication and processing of next-generation oxygen carrier materials for chemical looping combustion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nadarajah, Arunan

    Among numerous methods of controlling the global warming effect, Chemical Looping Combustion is known to be the most viable option currently. A key factor to a successful chemical looping process is the presence of highly effective oxygen carriers that enable fuel combustion by going through oxidation and reduction in the presence of air and fuel respectively. In this study, CaMnO 3-δ was used as the base material and doped on the A-site (Sr or La) and B-site (Fe, Ti, Zn and Al) by 10 mol % of dopants. Solid state reaction followed by mechanical extrusion (optimized paste formula) was usedmore » as the preparation method A series of novel doped perovskite-type oxygen carrier particles (Ca xLa (Or Sa) 1-x Mn 1-yByO 3-δ (B-site = Fe, Ti, Al, or Zr)) were synthesized by the proposed extrusion formula. The produced samples were characterized with XRD, SEM, BET and TGA techniques. According to the results obtained from TGA analysis, the oxygen capacity of the samples ranged between 1.2 for CLMZ and 1.75 for CSMF. Reactivity and oxygen uncoupling behaviors of the prepared samples were also evaluated using a fluidized bed chemical looping reactor using methane as the fuel at four different temperatures (800, 850, 900, 950 °C). All of the oxygen carriers showed oxygen uncoupling behavior and they were able to capture and release oxygen. Mass-based conversion of the perovskites was calculated and temperature increase proved to increase the mass-based conversion rate in all of the samples under study. Gas yield was calculated at 950 °C as well, and results showed that CLMZ, CM and CSMF showed 100% gas yields and CLMF and CSMZ showed approximately 85% yield in fluidized bed reactor, which is a high and acceptable quantity. Based on extended reactor tests the modified calcium manganese perovskite structures (CSMF) can be a good candidate for future pilot tests.« less

  6. Particulate Formation from a Copper Oxide-Based Oxygen ...

    EPA Pesticide Factsheets

    Attrition behavior and particle loss of a copper oxide-based oxygen carrier from a methane chemical looping combustion (CLC) process was investigated in a fluidized bed reactor. The aerodynamic diameters of most elutriated particulates, after passing through a horizontal settling duct, range between 2 and 5 μm. A notable number of submicron particulates are also identified. Oxygen carrier attrition was observed to lead to increased CuO loss resulting from the chemical looping reactions, i.e., Cu is enriched in small particles generated primarily from fragmentation in the size range of 10-75 μm. Cyclic reduction and oxidation reactions in CLC have been determined to weaken the oxygen carrier particles, resulting in increased particulate emission rates when compared to oxygen carriers without redox reactions. The generation rate for particulates < 10 μm was found to decrease with progressive cycles over as-prepared oxygen carrier particles and then reach a steady state. The surface of the oxygen carrier is also found to be coarsened due to a Kirkendall effect, which also explains the enrichment of Cu on particle surfaces and in small particles. As a result, it is important to collect and reprocess small particles generated from chemical looping processes to reduce oxygen carrier loss. The redox reactions associated with chemical looping combustion play an important role in particle attrition in the fluidized bed. Reaction-induced local stresses, due to the r

  7. Synthesis of Human Haemoglobin by Plants

    ERIC Educational Resources Information Center

    Onyesom, I.

    2006-01-01

    Haemoglobin, Hb is the red, protein pigment in blood that transports oxygen round the body. Decreased quantity could lead to anaemia, and when the anaemic condition turns severe, blood transfusion becomes inevitable. However, the safety of human source has become questionable in recent times, and this has aroused the interest of scientists to…

  8. Chemical-Looping Combustion and Gasification of Coals and Oxygen Carrier Development: A Brief Review

    DOE PAGES

    Wang, Ping; Means, Nicholas; Shekhawat, Dushyant; ...

    2015-09-24

    Chemical-looping technology is one of the promising CO 2 capture technologies. It generates a CO 2 enriched flue gas, which will greatly benefit CO 2 capture, utilization or sequestration. Both chemical-looping combustion (CLC) and chemical-looping gasification (CLG) have the potential to be used to generate power, chemicals, and liquid fuels. Chemical-looping is an oxygen transporting process using oxygen carriers. Recently, attention has focused on solid fuels such as coal. Coal chemical-looping reactions are more complicated than gaseous fuels due to coal properties (like mineral matter) and the complex reaction pathways involving solid fuels. The mineral matter/ash and sulfur in coalmore » may affect the activity of oxygen carriers. Oxygen carriers are the key issue in chemical-looping processes. Thermogravimetric analysis (TGA) has been widely used for the development of oxygen carriers (e.g., oxide reactivity). Two proposed processes for the CLC of solid fuels are in-situ Gasification Chemical-Looping Combustion (iG-CLC) and Chemical-Looping with Oxygen Uncoupling (CLOU). The objectives of this review are to discuss various chemical-looping processes with coal, summarize TGA applications in oxygen carrier development, and outline the major challenges associated with coal chemical-looping in iG-CLC and CLOU.« less

  9. A Hemoglobin Based Oxygen Carrier, Bovine Polymerized Hemoglobin (HBOC-201) versus Hetastarch (HEX) in an Uncontrolled Liver Injury Hemorrhagic Shock Swine Model with Delayed Evacuation

    DTIC Science & Technology

    2004-10-01

    A Hemoglobin Based Oxygen Carrier, Bovine Polymerized Hemoglobin (HBOC-201) versus Hetastarch (HEX) in an Uncontrolled Liver Injury Hemorrhagic Shock...Transcutaneous tis- sue oxygenation was restored more rap- idly in HBOC-201 pigs, there was a trend to lower lactic acid, and base deficit was less...lactic acidosis and base deficit (BD) abnormalities, indicating on-going hypoperfusion.2–4 As these abnormalities measured upon hospital arrival

  10. New developments in anti-sickling agents: can drugs directly prevent the polymerization of sickle haemoglobin in vivo?

    PubMed

    Oder, Esther; Safo, Martin K; Abdulmalik, Osheiza; Kato, Gregory J

    2016-10-01

    The hallmark of sickle cell disease is the polymerization of sickle haemoglobin due to a point mutation in the β-globin gene (HBB). Under low oxygen saturation, sickle haemoglobin assumes the tense (T-state) deoxygenated conformation that can form polymers, leading to rigid erythrocytes with impaired blood vessel transit, compounded or initiated by adhesion of erythrocytes to endothelium, neutrophils and platelets. This process results in vessel occlusion and ischaemia, with consequent acute pain, chronic organ damage, morbidity and mortality. Pharmacological agents that stabilize the higher oxygen affinity relaxed state (R-state) and/or destabilize the lower oxygen affinity T-state of haemoglobin have the potential to delay the sickling of circulating red cells by slowing polymerization kinetics. Relevant classes of agents include aromatic aldehydes, thiol derivatives, isothiocyanates and acyl salicylates derivatives. The aromatic aldehyde, 5-hydroxymethylfurfural (5-HMF) increases oxygen affinity of sickle haemoglobin and reduces hypoxia-induced sickling in vitro and protects sickle cell mice from effects of hypoxia. It has completed pre-clinical testing and has entered clinical trials as treatment for sickle cell disease. A related molecule, GBT440, has shown R-state stabilization and increased oxygen affinity in preclinical testing. Allosteric modifiers of haemoglobin as direct anti-sickling agents target the fundamental pathophysiological mechanism of sickle cell disease. © 2016 John Wiley & Sons Ltd.

  11. Impact of acellular hemoglobin-based oxygen carriers on brain apoptosis in rats.

    PubMed

    Vandegriff, Kim D; Malavalli, Ashok; Lohman, Jeff; Young, Mark A; Terraneo, Laura; Virgili, Eleonora; Bianciardi, Paola; Caretti, Anna; Samaja, Michele

    2014-08-01

    Extracellular hemoglobin (Hb)-based oxygen carriers (HBOCs) are under extensive consideration as oxygen therapeutics. Their effects on cellular mechanisms related to apoptosis are of particular interest, because the onset of proapoptotic pathways may give rise to tissue damage. The objective was to assess whether the properties of the Hb that replaces blood during an isovolemic hemodilution would modulate apoptotic-response mechanisms in rat brain and whether such signaling favors cytoprotection or damage. We exposed rats to exchange transfusion (ET; 50% blood volume and isovolemic replacement with Hextend [negative colloid control], MP4OX [PEGylated HBOC with high oxygen affinity], and ααHb [αα-cross-linked HBOC with low oxygen affinity; n=4-6/group]). Sham rats acted as control. Animals were euthanized at 2, 6, and 12 hours after ET; brain tissue was harvested and processed for analysis. In MP4OX animals, the number of neurons that overexpressed the hypoxia-inducible factor (HIF)-1α was higher than in ααHb, particularly at the early time points. In addition, MP4OX was associated with greater phosphorylation of protein kinase B (Akt), a well-known cytoprotective factor. Indeed, the degree of apoptosis, measured as terminal deoxynucleotidyl transferase-positive neurons and caspase-3 cleavage, ranked in order of MP4OX < Hextend < ααHb. Even though both HBOCs showed increased levels of HIF-1α compared to shams or Hextend-treated animals, differences in signaling events resulted in very different outcomes for the two HBOCs. ααHb-treated brain tissue showed significant neuronal damage, measured as apoptosis. This was in stark contrast to the protection seen with MP4OX, apparently due to recruitment of Akt and neuronal specific HIF-1α pathways. © 2014 Sangart, Inc. Transfusion © 2014 AABB.

  12. Solid waste management of a chemical-looping combustion plant using Cu-based oxygen carriers.

    PubMed

    García-Labiano, Francisco; Gayán, Pilar; Adánez, Juan; De Diego, Luis F; Forero, Carmen R

    2007-08-15

    Waste management generated from a Chemical-Looping Combustion (CLC) plant using copper-based materials is analyzed by two ways: the recovery and recycling of the used material and the disposal of the waste. A copper recovery process coupled to the CLC plant is proposed to avoid the loss of active material generated by elutriation from the system. Solid residues obtained from a 10 kWth CLC prototype operated during 100 h with a CuO-Al2O3 oxygen carrier prepared by impregnation were used as raw material in the recovery process. Recovering efficiencies of approximately 80% were obtained in the process, where the final products were an eluate of Cu(NO3)2 and a solid. The eluate was used for preparation of new oxygen carriers by impregnation, which exhibited high reactivity for reduction and oxidation reactions as well as adequate physical and chemical properties to be used in a CLC plant. The proposed recovery process largely decreases the amount of natural resources (Cu and Al203) employed in a CLC power plant as well as the waste generated in the process. To determine the stability of the different solid streams during deposition in a landfill, these were characterized with respect to their leaching behavior according to the European Union normative. The solid residue finally obtained in the CLC plant coupled to the recovery process (composed by Al2O3 and CuAl2O4) can be classified as a stable nonreactive hazardous waste acceptable at landfills for nonhazardous wastes.

  13. Purification, crystallization and preliminary crystallographic studies of haemoglobin from mongoose (Helogale parvula) in two different crystal forms induced by pH variation.

    PubMed

    Mohamed Abubakkar, M; Saraboji, K; Ponnuswamy, M N

    2013-02-01

    Haemoglobin (Hb) is a respiratory pigment; it is a tetrameric protein that ferries oxygen from the lungs to tissues and transports carbon dioxide on the return journey. The oxygen affinity of haemoglobin is regulated by the concentration of oxygen surrounding it and several efforts have revealed the shapes of Hb in different states and with different functions. However, study of the molecular basis of Hbs from low-oxygen-affinity species is critically needed in order to increase the understanding of the mechanism behind oxygen adaptation. The present study reports the preliminary crystallographic study of low-oxygen-affinity haemoglobin from mongoose, a burrowing mammal. Haemoglobin from mongoose was purified by anion-exchange chromatography, crystallized using the hanging-drop vapour-diffusion method and diffraction data sets were collected from monoclinic (2.3 Å resolution) and orthorhombic (2.9 Å resolution) crystal forms obtained by pH variation. The monoclinic and orthorhombic asymmetric units contained half and a whole biological molecule, respectively.

  14. Purification, crystallization and preliminary crystallographic studies of haemoglobin from mongoose (Helogale parvula) in two different crystal forms induced by pH variation

    PubMed Central

    Mohamed Abubakkar, M.; Saraboji, K.; Ponnuswamy, M. N.

    2013-01-01

    Haemoglobin (Hb) is a respiratory pigment; it is a tetrameric protein that ferries oxygen from the lungs to tissues and transports carbon dioxide on the return journey. The oxygen affinity of haemoglobin is regulated by the concentration of oxygen surrounding it and several efforts have revealed the shapes of Hb in different states and with different functions. However, study of the molecular basis of Hbs from low-oxygen-affinity species is critically needed in order to increase the understanding of the mechanism behind oxygen adaptation. The present study reports the preliminary crystallographic study of low-oxygen-affinity haemoglobin from mongoose, a burrowing mammal. Haemoglobin from mongoose was purified by anion-exchange chromatography, crystallized using the hanging-drop vapour-diffusion method and diffraction data sets were collected from monoclinic (2.3 Å resolution) and orthorhombic (2.9 Å resolution) crystal forms obtained by pH variation. The monoclinic and orthorhombic asymmetric units contained half and a whole biological molecule, respectively. PMID:23385751

  15. Maternal haemoglobin concentrations before and during pregnancy and stillbirth risk: a population-based case-control study.

    PubMed

    Maghsoudlou, Siavash; Cnattingius, Sven; Stephansson, Olof; Aarabi, Mohsen; Semnani, Shahriar; Montgomery, Scott M; Bahmanyar, Shahram

    2016-06-03

    Results of previous studies on the association between maternal haemoglobin concentration during pregnancy and stillbirth risk are inconclusive. It is not clear if haemoglobin concentration before pregnancy has a role. Using prospectively collected information from pre-pregnancy and antenatal visits, we investigated associations of maternal haemoglobin concentrations before and during pregnancy and haemoglobin dilution with stillbirth risk. In a population-based case-control study from rural Golestan, a province in northern Iran, we identified 495 stillbirths (cases) and randomly selected 2,888 control live births among antenatal health-care visits between 2007 and 2009. Using logistic regression, we estimated associations of maternal haemoglobin concentrations, haemoglobin dilution at different stages of pregnancy, with stillbirth risk. Compared with normal maternal haemoglobin concentration (110-120 g/l) at the end of the second trimester, high maternal haemoglobin concentration (≥140 g/l) was associated with a more than two-fold increased stillbirth risk (OR = 2.31, 95 % CI [1.30-4.10]), while low maternal haemoglobin concentration (<110 g/l) was associated with a 37 % reduction in stillbirth risk. Haemoglobin concentration before pregnancy was not associated with stillbirth risk. Decreased haemoglobin concentration, as measured during pregnancy (OR = 0.61, 95 % CI [0.46, 0.80]), or only during the second trimester (OR = 0.75, 95 % CI [0.62, 0.90]), were associated with reduced stillbirth risk. The associations were essentially similar for preterm and term stillbirths. Haemoglobin concentration before pregnancy is not associated with stillbirth risk. High haemoglobin level and absence of haemoglobin dilution during pregnancy could be considered as indicators of a high-risk pregnancy.

  16. Approaching the evolutionary advantage of ancillary types of haemoglobin in Daphnia magna by simulation of oxygen supply.

    PubMed

    Moenickes, S; Richter, O; Pirow, R

    2010-02-01

    The planktonic crustacean Daphnia magna synthesizes haemoglobin (Hb) macromolecules of variant subunit composition and oxygen affinity. This is one of the strategies by which the animals cope with variations in environmental conditions such as ambient oxygen tension. The enrichment of high-affinity Hb molecules in the haemolymph of hypoxia-exposed animals is thought to reduce Hb synthesis costs due to an enhanced transport efficiency of these molecules in comparison to the low-affinity Hb molecules. How great this economic advantage is, and under which conditions this benefit disappears, is still not fully understood. Here we implemented a rigorously simplified model of the daphnid body and described the transport of oxygen from the environment via the haemolymph to the tissues in terms of the convection-diffusion-reaction equation. The model was validated by comparing various model predictions with experimental data. A sensitivity analysis was used to evaluate the influence of parameter uncertainties on the model predictions. Cost-benefit analysis revealed in which way at the system's level the increase in Hb oxygen affinity improves the oxygen loading at the respiratory surfaces and impairs the release of oxygen to the tissues. The benefit arising from the improved oxygen loading exceeds the disadvantage of impaired unloading only under conditions where the ambient oxygen tension is critically low and the Hb concentration is high. The low-affinity Hb, on the other hand, provides an advantage given that the Hb concentration is low and the ambient oxygen tension is well above the critical level. Computer-aided modelling and simulation therefore provide valuable mechanistic insights into the driving forces that could have shaped the evolution of globin genes in daphnids.

  17. Complete healing of chronic wounds of a lower leg with haemoglobin spray and regeneration of an accompanying severe dermatoliposclerosis with intermittent normobaric oxygen inhalation (INBOI): a case report

    PubMed Central

    Barnikol, Wolfgang K. R.; Pötzschke, Harald

    2011-01-01

    A new healing procedure has been developed on the basis of the successful treatment of therapy-resistant hypoxic (and practically anoxic) leg ulcerations located within a heavy dermatoliposclerosis. The procedure involves an initial intra-ulceral application of haemoglobin followed by the intermittent administration of normobaric oxygen via inhalation. Haemoglobin is capable of externally supplying the granulating wound bed with oxygen at low partial pressure in a physiological manner, like a micro lung, so that oxidative stress can be avoided. A long-term daily administration of oxygen from within – including the peri-ulceral skin – is achieved by intermittent normobaric oxygen inhalation (INBOI) regularly throughout the day in the form of 1-hour sessions. Using this combined healing treatment during haemoglobin applications the ulcerations healed within about 1 month, and subsequently with INBOI therapy within further approx. 4 months the peri-ulceral skin regenerated as far as the oxygenation status was concerned: The peri-ulceral transcutaneous oxygen partial pressure (tcPO2) of zero (measured during breathing of normal air) rose to a satisfactory value of approx. 35 mmHg. After 28 months of treatment, the completely hypoxic and degenerated skin on the leg had practically returned to normal with a PO2 of 45 mmHg. Furthermore, the skin dermatoliposclerosis regressed. The skin regeneration was long-lasting, which was probably related to cellular tissue regeneration with an increase in the capillary density, whereby it had to be maintained by regular oxygen inhalation (INBOI maintaining treatment). By unintended intra-individual therapy variations it is evidenced that local hypoxia was the reason for skin degeneration: 3 x 1 h oxygen inhalation were sufficient for the healing treatment; 2 x 1 h sufficed for maintenance, whereas 2 x 0.5 h did not. The new procedure carries practically no risks, is simple, cheap and effective. Whereas the application of

  18. The effects on increasing cardiac output with adrenaline or isoprenaline on arterial haemoglobin oxygen saturation and shunt during one-lung ventilation.

    PubMed

    Russell, W J; James, M F

    2000-12-01

    Theoretically, if the cardiac output were increased in the presence of a given intrapulmonary shunt, the arterial haemoglobin oxygen saturation (SaO2) should improve as the venous oxygen extraction per ml of blood decreases. To test this hypothesis, eight pigs were subjected to one-lung ventilation and adrenaline and isoprenaline infusions used to increase the cardiac output. The mixed venous oxygen, shunt fraction and oxygen consumption were measured. With both adrenaline and isoprenaline, although there was a small rise in mixed venous oxygen content, there was a fall in SaO2. With adrenaline, the mean shunt rose from 48% to 65%, the mean oxygen consumption rose from 126 ml/min to 134 ml/min and the mean SaO2 fell from 86.9% to 82.5%. With isoprenaline, the mean shunt rose from 45% to 59%, the mean oxygen consumption rose from 121 ml/min to 137 ml/min and the mean SaO2 fell from 89.5% to 84.7%. It is concluded that potential improvement in SaO2, which might occur from a catecholamine-induced increase in mixed venous oxygen content during one-lung ventilation, is more than offset by increased shunting and oxygen consumption which reduce SaO2.

  19. Significance of oxygen carriers and role of liquid paraffin in improving validamycin A production.

    PubMed

    Feng, Jinsong; Jiang, Jing; Liu, Yan; Li, Wei; Azat, Ramila; Zheng, Xiaodong; Zhou, Wen-Wen

    2016-10-01

    Validamycin A (Val-A) synthesized by Streptomyces hygroscopicus 5008 is widely used as a high-efficient antibiotic to protect plants from sheath blight disease. A novel fermentation strategy was introduced to stimulate Val-A production by adding oxygen carriers. About 58 % increase in Val-A production was achieved using liquid paraffin. Further, biomass, carbon source, metabolic genes, and metabolic enzymes were studied. It was also found that the supplementation of liquid paraffin increased the medium dissolved oxygen and intracellular oxidative stress level. The expression of the global regulators afsR and soxR sensitive to ROS, ugp catalyzing synthesis of Val-A precursor, and Val-A structural genes was enhanced. The change of the activities of glucose-6-phosphate dehydrogenase and glyceraldehyde 3-phosphate dehydrogenase was observed, which reflected the redirection of carbon metabolic flux. Based on these results, liquid paraffin addition as an oxygen carrier could be a useful technique in industrial production of Val-A and our study revealed a redox-based secondary metabolic regulation in S. hygroscopicus 5008, which provided a new insight into the regulation of the biosynthesis of secondary metabolites.

  20. Pressurized chemical-looping combustion of coal with an iron ore-based oxygen carrier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiao, Rui; Song, Min; Zhang, Shuai

    2010-06-15

    Chemical-looping combustion (CLC) is a new combustion technology with inherent separation of CO{sub 2}. Most of the previous investigations on CLC of solid fuels were conducted under atmospheric pressure. A pressurized CLC combined cycle (PCLC-CC) system is proposed as a promising coal combustion technology with potential higher system efficiency, higher fuel conversion, and lower cost for CO{sub 2} sequestration. In this study pressurized CLC of coal with Companhia Valedo Rio Doce (CVRD) iron ore was investigated in a laboratory fixed bed reactor. CVRD iron ore particles were exposed alternately to reduction by 0.4 g of Chinese Xuzhou bituminous coal gasifiedmore » with 87.2% steam/N{sub 2} mixture and oxidation with 5% O{sub 2} in N{sub 2} at 970 C. The operating pressure was varied between 0.1 MPa and 0.6 MPa. First, control experiments of steam coal gasification over quartz sand were performed. H{sub 2} and CO{sub 2} are the major components of the gasification products, and the operating pressure influences the gas composition. Higher concentrations of CO{sub 2} and lower fractions of CO, CH{sub 4}, and H{sub 2} during the reduction process with CVRD iron ore was achieved under higher pressures. The effects of pressure on the coal gasification rate in the presence of the oxygen carrier were different for pyrolysis and char gasification. The pressurized condition suppresses the initial coal pyrolysis process while it also enhances coal char gasification and reduction with iron ore in steam, and thus improves the overall reaction rate of CLC. The oxidation rates and variation of oxygen carrier conversion are higher at elevated pressures reflecting higher reduction level in the previous reduction period. Scanning electron microscope and energy-dispersive X-ray spectroscopy (SEM-EDX) analyses show that particles become porous after experiments but maintain structure and size after several cycles. Agglomeration was not observed in this study. An EDX analysis

  1. Haemoglobin recovery among HIV-1 infected patients on zidovudine-based antiretroviral therapy and other regimens in north-central Nigeria.

    PubMed

    Parrish, Deidra D; Blevins, Meridith; Megazzini, Karen M; Shepherd, Bryan E; Mohammed, Mukhtar Y; Wester, C William; Vermund, Sten H; Aliyu, Muktar H

    2014-04-01

    We conducted a study to assess trends in haemoglobin recovery among HIV-infected patients initiated on zidovudine-based combination antiretroviral therapy (cART) stratified by baseline haemoglobin level. Haemoglobin data from non-pregnant adult patients initiating cART in rural north-central Nigeria between June 2009 and May 2011 were analysed using a linear mixed effects model to assess the interaction between time, zidovudine-containing regimen and baseline haemoglobin level on the outcome of subsequent haemoglobin level. Best-fit curves were created for baseline haemoglobin in the 10th, 25th, 75th and 90th percentiles. We included 313 patients with 736 measures of haemoglobin in the analysis (239 on zidovudine and 74 on non-zidovudine-containing regimens). Median haemoglobin increased over time in both groups, with differences in haemoglobin response over time related to baseline haemoglobin levels and zidovudine use (p = 0.003). The groups of patients on zidovudine at the 10th and 90th percentiles had downward sloping curves while all other groups had upward trending haemoglobin levels. Although haemoglobin levels increased overall for patients on zidovudine-containing regimens, for those in the 10th and 90th percentiles haemoglobin levels trended downward over time. These results have implications for decisions regarding when to initiate, switch from or avoid the use of zidovudine.

  2. Effects of prolonged compression on the variations of haemoglobin oxygenation—assessment by spectral analysis of reflectance spectrophotometry signals

    NASA Astrophysics Data System (ADS)

    Li, Zengyong; Tam, Eric W. C.; Mak, Arthur F. T.; Lau, Roy Y. C.

    2006-11-01

    The consequences of rhythmical flow motion for nutrition and the oxygen supply to tissue are largely unknown. In this study, the periodic variations of haemoglobin oxygenation in compressed and uncompressed skin were evaluated with a reflection spectrometer using an in vivo Sprague-Dawley rat model. Skin compression was induced over the trochanter area by a locally applied external pressure of 13.3 kPa (100 mmHg) via a specifically designed pneumatic indentor. A total of 19 rats were used in this study. The loading duration is 6 h per day for four consecutive days. Haemoglobin oxygenation variations were quantified using spectral analysis based on wavelets' transformation. The results found that in both compressed and uncompressed skin, periodic variations of the haemoglobin oxygenation were characterized by two frequencies in the range of 0.01-0.05 Hz and 0.15-0.4 Hz. These frequency ranges coincide with those of the frequency range of the endothelial-related metabolic and myogenic activities found in the flow motion respectively. Tissue compression following the above loading schedule induced a significant decrease in the spectral amplitudes of frequency interval 0.01-0.05 Hz during the pre-occlusion period on day 3 and day 4 as compared to that on day 1 (p < 0.05). In contrast, at a frequency range of 0.15-0.4 Hz, prolonged compression caused a significant increase in spectral amplitude during the pre-occlusion period in the compressed tissue on day 3 (p = 0.041) and day 4 (p = 0.024) compared to that in the uncompressed tissue on day 1. These suggested that the variations of the haemoglobin oxygenation were closely related to the endothelial-related metabolic and myogenic activities. Increased amplitude in the frequency interval 0.15-0.4 Hz indicated an increased workload of the vascular smooth muscle and could be attributed to the increase of O2 consumption rates of arteriolar walls. The modification of vessel wall oxygen consumption might substantially affect

  3. The Use of an Acellular Oxygen Carrier in a Human Liver Model of Normothermic Machine Perfusion.

    PubMed

    Laing, Richard W; Bhogal, Ricky H; Wallace, Lorraine; Boteon, Yuri; Neil, Desley A H; Smith, Amanda; Stephenson, Barney T F; Schlegel, Andrea; Hübscher, Stefan G; Mirza, Darius F; Afford, Simon C; Mergental, Hynek

    2017-11-01

    Normothermic machine perfusion of the liver (NMP-L) is a novel technique that preserves liver grafts under near-physiological conditions while maintaining their normal metabolic activity. This process requires an adequate oxygen supply, typically delivered by packed red blood cells (RBC). We present the first experience using an acellular hemoglobin-based oxygen carrier (HBOC) Hemopure in a human model of NMP-L. Five discarded high-risk human livers were perfused with HBOC-based perfusion fluid and matched to 5 RBC-perfused livers. Perfusion parameters, oxygen extraction, metabolic activity, and histological features were compared during 6 hours of NMP-L. The cytotoxicity of Hemopure was also tested on human hepatic primary cell line cultures using an in vitro model of ischemia reperfusion injury. The vascular flow parameters and the perfusate lactate clearance were similar in both groups. The HBOC-perfused livers extracted more oxygen than those perfused with RBCs (O2 extraction ratio 13.75 vs 9.43 % ×10 per gram of tissue, P = 0.001). In vitro exposure to Hemopure did not alter intracellular levels of reactive oxygen species, and there was no increase in apoptosis or necrosis observed in any of the tested cell lines. Histological findings were comparable between groups. There was no evidence of histological damage caused by Hemopure. Hemopure can be used as an alternative oxygen carrier to packed red cells in NMP-L perfusion fluid.

  4. Regenerable mixed copper-iron-inert support oxygen carriers for solid fuel chemical looping combustion process

    DOEpatents

    Siriwardane, Ranjani V.; Tian, Hanjing

    2016-12-20

    The disclosure provides an oxygen carrier for a chemical looping cycle, such as the chemical looping combustion of solid carbonaceous fuels, such as coal, coke, coal and biomass char, and the like. The oxygen carrier is comprised of at least 24 weight % (wt %) CuO, at least 10 wt % Fe2O3, and an inert support, and is typically a calcine. The oxygen carrier exhibits a CuO crystalline structure and an absence of iron oxide crystalline structures under XRD crystallography, and provides an improved and sustained combustion reactivity in the temperature range of 600.degree. C.-1000.degree. C. particularly for solid fuels such as carbon and coal.

  5. Insensitivity of cerebral oxygen transport to oxygen affinity of hemoglobin-based oxygen carriers

    PubMed Central

    Koehler, Raymond C.; Fronticelli, Clara; Bucci, Enrico

    2008-01-01

    The cerebrovascular effects of exchange transfusion of various cell-free hemoglobins that possess different oxygen affinities are reviewed. Reducing hematocrit by transfusion of a non-oxygen-carrying solution dilates pial arterioles on the brain surface and increases cerebral blood flow to maintain a constant bulk oxygen transport to the brain. In contrast, transfusion of hemoglobins with P50 of 4–34 Torr causes constriction of pial arterioles that offsets the decrease in blood viscosity to maintain cerebral blood flow and oxygen transport. The autoregulatory constriction is dependent on synthesis of 20-HETE from arachidonic acid. This oxygen-dependent reaction is apparently enhanced by facilitated oxygen diffusion from the red cell to the endothelium arising from increased plasma oxygen solubility in the presence of low or high-affinity hemoglobin. Exchange transfusion of recombinant hemoglobin polymers with P50 of 3 and 18 Torr reduces infarct volume from experimental stroke. Cell-free hemoglobins do not require a P50 as high as red blood cell hemoglobin to facilitate oxygen delivery. PMID:18230370

  6. Insensitivity of cerebral oxygen transport to oxygen affinity of hemoglobin-based oxygen carriers.

    PubMed

    Koehler, Raymond C; Fronticelli, Clara; Bucci, Enrico

    2008-10-01

    The cerebrovascular effects of exchange transfusion of various cell-free hemoglobins that possess different oxygen affinities are reviewed. Reducing hematocrit by transfusion of a non-oxygen-carrying solution dilates pial arterioles on the brain surface and increases cerebral blood flow to maintain a constant bulk oxygen transport to the brain. In contrast, transfusion of hemoglobins with P50 of 4-34 Torr causes constriction of pial arterioles that offsets the decrease in blood viscosity to maintain cerebral blood flow and oxygen transport. The autoregulatory constriction is dependent on synthesis of 20-HETE from arachidonic acid. This oxygen-dependent reaction is apparently enhanced by facilitated oxygen diffusion from the red cell to the endothelium arising from increased plasma oxygen solubility in the presence of low or high-affinity hemoglobin. Exchange transfusion of recombinant hemoglobin polymers with P50 of 3 and 18 Torr reduces infarct volume from experimental stroke. Cell-free hemoglobins do not require a P50 as high as red blood cell hemoglobin to facilitate oxygen delivery.

  7. Hydrogen ion titrations of the anodic and cathodic haemoglobin components of the European eel Anguilla anguilla.

    PubMed

    Brauner, C J; Weber, R E

    1998-09-01

    H+ titrations were conducted on the separated haemoglobin components of eel Anguilla anguilla in both the oxygenated and deoxygenated states. In anodic haemoglobin, the addition of GTP, and to a lesser extent C1-, increased the magnitude of the Haldane effect and shifted its maximum value into the in vivo pH range. Of the 22 histidine residues in the anodic component, only approximately seven were titratable, presumably the beta-chain residues at positions 41, 97, 109 and 146 (helical positions C7, FG4, G11 and HC3, respectively). In cathodic haemoglobin, a small negative Haldane effect was observed at pH values between 6.8 and 8.5 which disappeared in the presence of GTP (molar ratio 3:1 GTP:haemoglobin tetramer). GTP had virtually no effect on the buffer value at fixed oxygenation status, and the lowest buffer value was observed at in vivo pH values. No titratable histidine residues were observed in the cathodic component, indicating that all 14 histidines in this component are buried. We conclude that the anodic component, which constitutes two-thirds of the haemoglobin in the eel, plays the predominant role in CO2 transport and pH homeostasis in vivo.

  8. Effect of temperature on reduction of CaSO{sub 4} oxygen carrier in chemical-looping combustion of simulated coal gas in a fluidized bed reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Q.L.; Xiao, R.; Deng, Z.Y.

    2008-12-15

    Chemical-looping combustion (CLC) is a promising combustion technology for gaseous and solid fuel with efficient use of energy and inherent separation of CO{sub 2}. The concept of a coal-fueled CLC system using, calcium sulfate (CaSO{sub 4}) as oxygen carrier is proposed in this study. Reduction tests of CaSO{sub 4} oxygen carrier with simulated coal gas were performed in a laboratory-scale fluidized bed reactor in the temperature range of 890-950{degree}C. A high concentration of CO{sub 2} was obtained at the initial reduction period. CaSO{sub 4} oxygen carrier exhibited high reactivity initially and decreased gradually at the late period of reduction. Themore » sulfur release during the reduction of CaSO{sub 4} as oxygen carrier was also observed and analyzed. H{sub 2} and CO{sub 2} conversions were greatly influenced by reduction temperature. The oxygen carrier conversion and mass-based reaction rates during the reduction at typical temperatures were compared. Higher temperatures would enhance reaction rates and result in high conversion of oxygen carrier. An XRD patterns study indicated that CaS was the dominant product of reduction and the variation of relative intensity with temperature is in agreement with the solid conversion. ESEM analysis indicated that the surface structure of oxygen carrier particles changed significantly from impervious to porous after reduction. EDS analysis also demonstrated the transfer of oxygen from the oxygen carrier to the fuel gas and a certain amount of sulfur loss and CaO formation on the surface at higher temperatures. The reduction kinetics of CaSO{sub 4} oxygen carrier was explored with the shrinking unreacted-core model. The apparent kinetic parameters were obtained, and the kinetic equation well predicted the experimental data. Finally, some basic considerations on the use of CaSO{sub 4} oxygen carrier in a CLC system for solid fuels were discussed.« less

  9. A Cross-Reactive Monoclonal Antibody to Nematode Haemoglobin Enhances Protective Immune Responses to Nippostrongylus brasiliensis

    PubMed Central

    Nieuwenhuizen, Natalie E.; Meter, Jeanne M.; Horsnell, William G.; Hoving, J. Claire; Fick, Lizette; Sharp, Michael F.; Darby, Matthew G.; Parihar, Suraj P.; Brombacher, Frank; Lopata, Andreas L.

    2013-01-01

    Background Nematode secreted haemoglobins have unusually high affinity for oxygen and possess nitric oxide deoxygenase, and catalase activity thought to be important in protection against host immune responses to infection. In this study, we generated a monoclonal antibody (48Eg) against haemoglobin of the nematode Anisakis pegreffii, and aimed to characterize cross-reactivity of 4E8g against haemoglobins of different nematodes and its potential to mediate protective immunity against a murine hookworm infection. Methodology/Principal Findings Immunoprecipitation was used to isolate the 4E8g-binding antigen in Anisakis and Ascaris extracts, which were identified as haemoglobins by peptide mass fingerprinting and MS/MS. Immunological cross-reactivity was also demonstrated with haemoglobin of the rodent hookworm N. brasiliensis. Immunogenicity of nematode haemoglobin in mice and humans was tested by immunoblotting. Anisakis haemoglobin was recognized by IgG and IgE antibodies of Anisakis-infected mice, while Ascaris haemoglobin was recognized by IgG but not IgE antibodies in mouse and human sera. Sequencing of Anisakis haemoglobin revealed high similarity to haemoglobin of a related marine nematode, Psuedoterranova decipiens, which lacks the four –HKEE repeats of Ascaris haemoglobin important in octamer assembly. The localization of haemoglobin in the different parasites was examined by immunohistochemistry and associated with the excretory-secretary ducts in Anisakis, Ascaris and N. brasiliensis. Anisakis haemoglobin was strongly expressed in the L3 stage, unlike Ascaris haemoglobin, which is reportedly mainly expressed in adult worms. Passive immunization of mice with 4E8g prior to infection with N. brasiliensis enhanced protective Th2 immunity and led to a significant decrease in worm burdens. Conclusion The monoclonal antibody 4E8g targets haemoglobin in broadly equivalent anatomical locations in parasitic nematodes and enhances host immunity to a hookworm

  10. A cross-reactive monoclonal antibody to nematode haemoglobin enhances protective immune responses to Nippostrongylus brasiliensis.

    PubMed

    Nieuwenhuizen, Natalie E; Meter, Jeanne M; Horsnell, William G; Hoving, J Claire; Fick, Lizette; Sharp, Michael F; Darby, Matthew G; Parihar, Suraj P; Brombacher, Frank; Lopata, Andreas L

    2013-01-01

    Nematode secreted haemoglobins have unusually high affinity for oxygen and possess nitric oxide deoxygenase, and catalase activity thought to be important in protection against host immune responses to infection. In this study, we generated a monoclonal antibody (48Eg) against haemoglobin of the nematode Anisakis pegreffii, and aimed to characterize cross-reactivity of 4E8g against haemoglobins of different nematodes and its potential to mediate protective immunity against a murine hookworm infection. Immunoprecipitation was used to isolate the 4E8g-binding antigen in Anisakis and Ascaris extracts, which were identified as haemoglobins by peptide mass fingerprinting and MS/MS. Immunological cross-reactivity was also demonstrated with haemoglobin of the rodent hookworm N. brasiliensis. Immunogenicity of nematode haemoglobin in mice and humans was tested by immunoblotting. Anisakis haemoglobin was recognized by IgG and IgE antibodies of Anisakis-infected mice, while Ascaris haemoglobin was recognized by IgG but not IgE antibodies in mouse and human sera. Sequencing of Anisakis haemoglobin revealed high similarity to haemoglobin of a related marine nematode, Psuedoterranova decipiens, which lacks the four -HKEE repeats of Ascaris haemoglobin important in octamer assembly. The localization of haemoglobin in the different parasites was examined by immunohistochemistry and associated with the excretory-secretary ducts in Anisakis, Ascaris and N. brasiliensis. Anisakis haemoglobin was strongly expressed in the L3 stage, unlike Ascaris haemoglobin, which is reportedly mainly expressed in adult worms. Passive immunization of mice with 4E8g prior to infection with N. brasiliensis enhanced protective Th2 immunity and led to a significant decrease in worm burdens. The monoclonal antibody 4E8g targets haemoglobin in broadly equivalent anatomical locations in parasitic nematodes and enhances host immunity to a hookworm infection.

  11. The Use of an Acellular Oxygen Carrier in a Human Liver Model of Normothermic Machine Perfusion

    PubMed Central

    Wallace, Lorraine; Boteon, Yuri; Neil, Desley AH; Smith, Amanda; Stephenson, Barney TF; Schlegel, Andrea; Hübscher, Stefan G; Mirza, Darius F

    2017-01-01

    Background Normothermic machine perfusion of the liver (NMP-L) is a novel technique that preserves liver grafts under near-physiological conditions whilst maintaining their normal metabolic activity. This process requires an adequate oxygen supply, typically delivered by packed red blood cells (RBC). We present the first experience using an acellular hemoglobin-based oxygen carrier (HBOC) Hemopure in a human model of NMP-L. Methods Five discarded high-risk human livers were perfused with HBOC-based perfusion fluid and matched to 5 RBC-perfused livers. Perfusion parameters, oxygen extraction, metabolic activity and histological features were compared during 6 hours of NMP-L. The cytotoxicity of Hemopure was also tested on human hepatic primary cell line cultures using an in vitro model of ischemia reperfusion injury. Results The vascular flow parameters and the perfusate lactate clearance were similar in both groups. The HBOC-perfused livers extracted more oxygen than those perfused with RBCs (O2ER 13.75 vs 9.43 % x105 per gram of tissue, p=0.001). In vitro exposure to Hemopure did not alter intracellular levels of reactive oxygen species and there was no increase in apoptosis or necrosis observed in any of the tested cell lines. Histological findings were comparable between groups. There was no evidence of histological damage caused by Hemopure. Conclusion Hemopure can be used as an alternative oxygen carrier to packed red cells in NMP-L perfusion fluid. PMID:28520579

  12. From artificial red blood cells, oxygen carriers, and oxygen therapeutics to artificial cells, nanomedicine, and beyond

    PubMed Central

    Chang, Thomas M. S.

    2013-01-01

    The first experimental artificial red blood cells have all three major functions of red blood cells (rbc). However, the first practical one is a simple polyhemoglobin (PolyHb) that only has an oxygen-carrying function. This is now in routine clinical use in South Africa and Russia. An oxygen carrier with antioxidant functions, PolyHb-catalase-superoxide dismutase, can fulfill two of the three functions of rbc. Even more complete is one with all three functions of rbc in the form of PolyHb-catalase-superoxide dismutase-carbonic anhydrase. The most advanced ones are nanodimension artificial rbc with either PEG-lipid membrane or PEG-PLA polymermembrane. Extensions in to oxygen therapeutics include a PolyHb-tyrosinase that suppresses the growth of melanoma in a mice model. Another is a PolyHb-fibrinogen that is an oxygen carrier with platelet-like function. Research has now extended well beyond the original research on artificial rbc into many areas of artificial cells. These include nanoparticles, nanotubules, lipid vesicles, liposomes, polymer-tethered lipid vesicles, polymersomes, microcapsules, bioencapsulation, nanocapules, macroencapsulation, synthetic cells, and others. These are being used in nanotechnology, nanomedicine, regenerative medicine, enzyme/gene therapy, cell/stem cell therapy, biotechnology, drug delivery, hemoperfusion, nanosensers, and even by some groups in agriculture, industry, aquatic culture, nanocomputers, and nanorobotics. PMID:22409281

  13. Regenerable MgO promoted metal oxide oxygen carriers for chemical looping combustion

    DOEpatents

    Siriwardane, Ranjani V.; Miller, Duane D.

    2014-08-19

    The disclosure provides an oxygen carrier comprised of a plurality of metal oxide particles in contact with a plurality of MgO promoter particles. The MgO promoter particles increase the reaction rate and oxygen utilization of the metal oxide when contacting with a gaseous hydrocarbon at a temperature greater than about 725.degree. C. The promoted oxide solid is generally comprised of less than about 25 wt. % MgO, and may be prepared by physical mixing, incipient wetness impregnation, or other methods known in the art. The oxygen carrier exhibits a crystalline structure of the metal oxide and a crystalline structure of MgO under XRD crystallography, and retains these crystalline structures over subsequent redox cycles. In an embodiment, the metal oxide is Fe.sub.2O.sub.3, and the gaseous hydrocarbon is comprised of methane.

  14. Higher haemoglobin levels and dedicated trauma admission are associated with survival after severe traumatic brain injury.

    PubMed

    Baltazar, Gerard Anthony; Pate, Amy J; Panigrahi, Benita; Sharp, Audrey; Smith, Michael; Chendrasekhar, Akella

    2015-01-01

    Prevention of secondary brain injury is a key component of acute management of patients with severe traumatic brain injury (TBI). Haemoglobin concentration may have an impact on optimization of cerebral oxygenation. Patients with TBI may best be served by an organized trauma service. The objective is to determine if haemoglobin concentration or dedicated trauma admission has an impact on outcomes after severe TBI. This study retrospectively analysed consecutive patients with severe TBI admitted to a level-I trauma centre over 3 years. Patients <16 years-old and with length of stay (LOS) <24 hours were excluded. Data were collected on demographics; injury severity; LOS; admission service; survival to discharge; and haemoglobin levels from hospital days 1-7. Data were also collected on number of transfusions of packed red blood cells. The sample was stratified based on admission service and survival to discharge. Of 147 patients (age = 54.1 ± 3.7 years), overall mortality rate was 15.4% (n = 23). Overall, non-survivors had lower daily and 7-day mean haemoglobin levels (10.7 ± 0.9 vs. 12.9 ± 0.4 g dL(-1), p < 0.001). Non-surgical admissions had lower haemoglobin levels and a higher mortality rate (28.9% vs. 12.2%, p < 0.001) compared to dedicated trauma admissions. Among patients with severe TBI, higher haemoglobin levels and maintenance as a dedicated trauma admission are associated with higher survival to discharge.

  15. Multicycle study on chemical-looping combustion of simulated coal gas with a CaSO{sub 4} oxygen carrier in a fluidized bed reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qilei Song; Rui Xiao; Zhongyi Deng

    2008-11-15

    The cyclic test of a CaSO{sub 4}-based oxygen carrier (natural anhydrite) in alternating reducing simulated coal gas and oxidizing conditions was performed at 950{degree}C in a fluidized bed reactor at atmospheric pressure. A high concentration of CO{sub 2} was obtained in the reduction. The H{sub 2} and CO conversions and CO{sub 2} yield increased initially and final decreased significantly. The release of SO{sub 2} and H{sub 2}S during the cyclic test was found to be responsible for the decrease of reactivity of a CaSO{sub 4} oxygen carrier. The oxygen carrier conversion after the reduction reaction decreased gradually in the cyclicmore » test. Through the comparison of mass-based reaction rates as a function of mass conversion at typical cycles, it was also evident that the reactivity of a CaSO{sub 4} oxygen carrier increased for the initial cycles but finally decreased after around 15 cycles. X-ray diffraction analysis revealed that the presence and intensity of the reduction sulfur species was in accordance with the results of gas conversion. The content of CaO was higher than expected, suggesting the formation of SO{sub 2} and H{sub 2}S during the cycles. Surface morphology analysis demonstrates that the natural anhydrite particle surface varied from impervious to porous after the cyclic test. It was also observed that the small grains on the surface of the oxygen carrier sintered in the cyclic tests. Energy-dispersive spectrum analysis also demonstrated the decrease of oxygen intensity after reduction, and CaO became the main component after the 20th oxidation. Pore structure analysis suggested that the particles agglomerated or sintered in the cyclic tests. The possible method for sulfur mitigation is proposed. Finally, some basic consideration on the design criteria of a CLC system for solid fuels using a CaSO{sub 4} oxygen carrier is discussed by the references and provides direction for future work. 49 refs., 10 figs., 5 tabs.« less

  16. Investigation of reactions in a fluidized bed reactor during chemical looping combustion of coal/steam with copper oxide-iron oxide-alumina oxygen carrier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siriwardane, Ranjani; Benincosa, William; Riley, Jarrett

    This paper presents data on conversion of two different coals with a chemical looping oxygen carrier, CuO-Fe 2O 3-alumina, and over a range of conditions including steam and various levels of reduction of the oxygen carrier. Reactions of coal/steam/CuO-Fe 2O 3-alumina oxygen carrier and coal/steam/partially reduced CuO-Fe 2O 3-alumina oxygen carrier were investigated with Wyodak coal and Illinois #6 coal in a fluidized bed reactor. Temperature programmed reaction studies indicated that the oxygen carrier enhanced the steam gasification/combustion rates of both coals. Rates of gasification/combustion were higher with Wyodak coal (sub bituminous) than that with Illinois #6 coal (bituminous). Inmore » addition to the increase in reaction rates, the total moles of carbon that were gasified and combusted from coal/steam increased in the presence of the oxygen carrier. The reduced oxygen carrier promoted the water-gas shift reaction when reacted with synthesis gas in the presence of steam, but the reverse water gas shift reaction was observed when steam was not present. The partially reduced oxygen carrier enhanced the production of H 2 from coal/steam, which was different from the observations with un-reduced oxygen carrier. Water splitting reaction to produce H 2 was also observed with the reduced oxygen carrier. CuO-Fe 2O 3-alumina reacted with coal during the temperature ramp to 850 °C even in the absence of steam due to the chemical-looping oxygen uncoupling (CLOU) reaction. Here, the fourier transform infra-red (FTIR) analysis indicated the presence of volatile aromatics during the temperature ramp and these may have also contributed to the reactions with the oxygen carrier in the absence of steam. Increasing steam concentration had a negative effect on the CLOU reaction.« less

  17. Investigation of reactions in a fluidized bed reactor during chemical looping combustion of coal/steam with copper oxide-iron oxide-alumina oxygen carrier

    DOE PAGES

    Siriwardane, Ranjani; Benincosa, William; Riley, Jarrett; ...

    2016-10-06

    This paper presents data on conversion of two different coals with a chemical looping oxygen carrier, CuO-Fe 2O 3-alumina, and over a range of conditions including steam and various levels of reduction of the oxygen carrier. Reactions of coal/steam/CuO-Fe 2O 3-alumina oxygen carrier and coal/steam/partially reduced CuO-Fe 2O 3-alumina oxygen carrier were investigated with Wyodak coal and Illinois #6 coal in a fluidized bed reactor. Temperature programmed reaction studies indicated that the oxygen carrier enhanced the steam gasification/combustion rates of both coals. Rates of gasification/combustion were higher with Wyodak coal (sub bituminous) than that with Illinois #6 coal (bituminous). Inmore » addition to the increase in reaction rates, the total moles of carbon that were gasified and combusted from coal/steam increased in the presence of the oxygen carrier. The reduced oxygen carrier promoted the water-gas shift reaction when reacted with synthesis gas in the presence of steam, but the reverse water gas shift reaction was observed when steam was not present. The partially reduced oxygen carrier enhanced the production of H 2 from coal/steam, which was different from the observations with un-reduced oxygen carrier. Water splitting reaction to produce H 2 was also observed with the reduced oxygen carrier. CuO-Fe 2O 3-alumina reacted with coal during the temperature ramp to 850 °C even in the absence of steam due to the chemical-looping oxygen uncoupling (CLOU) reaction. Here, the fourier transform infra-red (FTIR) analysis indicated the presence of volatile aromatics during the temperature ramp and these may have also contributed to the reactions with the oxygen carrier in the absence of steam. Increasing steam concentration had a negative effect on the CLOU reaction.« less

  18. Risk factors and consequences of maternal anaemia and elevated haemoglobin levels during pregnancy: a population-based prospective cohort study.

    PubMed

    Gaillard, Romy; Eilers, Paul H C; Yassine, Siham; Hofman, Albert; Steegers, Eric A P; Jaddoe, Vincent W V

    2014-05-01

    To determine sociodemographic and life style-related risk factors and trimester specific maternal, placental, and fetal consequences of maternal anaemia and elevated haemoglobin levels in pregnancy. In a population-based prospective cohort study of 7317 mothers, we measured haemoglobin levels in early pregnancy [gestational age median 14.4 weeks (inter-quartile-range 12.5-17.5)]. Anaemia (haemoglobin ≤11 g/dl) and elevated haemoglobin levels (haemoglobin ≥13.2 g/dl) were defined according to the WHO criteria. Maternal blood pressure, placental function and fetal growth were measured in each trimester. Data on gestational hypertensive disorders and birth outcomes was collected from hospitals. Older maternal age, higher body mass index, primiparity and European descent were associated with higher haemoglobin levels (P < 0.05). Elevated haemoglobin levels were associated with increased systolic and diastolic blood pressure throughout pregnancy (mean differences 5.1 mmHg, 95% confidence interval [CI] 3.8, 6.5 and 4.1 mmHg, 95% CI 3.0, 5.2, respectively) and with a higher risk of third trimester uterine artery notching (RR 1.3, 95% CI 1.0, 1.7). As compared with maternal normal haemoglobin levels, not anaemia, but elevated haemoglobin levels were associated with fetal head circumference, length, and weight growth restriction from third trimester onwards (P < 0.05). Elevated haemoglobin levels were associated with increased risks of gestational hypertensive disorders (RR 1.4, 95% CI 1.1, 1.8) and adverse birth outcomes (RR 1.4, 95% CI 1.1, 1.7). In a low-risk population, various sociodemographic and life style factors affect haemoglobin levels during pregnancy. Elevated haemoglobin levels are associated with increased risks of maternal, placental, and fetal complications. © 2014 John Wiley & Sons Ltd.

  19. Evolutionary diversification of the trypanosome haptoglobin-haemoglobin receptor from an ancestral haemoglobin receptor.

    PubMed

    Lane-Serff, Harriet; MacGregor, Paula; Peacock, Lori; Macleod, Olivia Js; Kay, Christopher; Gibson, Wendy; Higgins, Matthew K; Carrington, Mark

    2016-04-15

    The haptoglobin-haemoglobin receptor of the African trypanosome species, Trypanosoma brucei, is expressed when the parasite is in the bloodstream of the mammalian host, allowing it to acquire haem through the uptake of haptoglobin-haemoglobin complexes. Here we show that in Trypanosoma congolense this receptor is instead expressed in the epimastigote developmental stage that occurs in the tsetse fly, where it acts as a haemoglobin receptor. We also present the structure of the T. congolense receptor in complex with haemoglobin. This allows us to propose an evolutionary history for this receptor, charting the structural and cellular changes that took place as it adapted from a role in the insect to a new role in the mammalian host.

  20. The distribution of haemoglobin S and other haemoglobin variants in a sample of Liberian paediatric subjects.

    PubMed

    Simbeye, A G

    1978-01-01

    The investigation of haemoglobin S in a sample of Liberian paediatric subjects revealed a relatively low incidence of this haemoglobin variant. There is no significant difference from its incidence in the adult population. The low frequency of haemoglobin S is rather paradoxal since malaria is still endemic in Liberia. Tribal variation has been revealed. Other haemoglobin variants were found to be rare.

  1. Influence of the formation- and passivation rate of boron-oxygen defects for mitigating carrier-induced degradation in silicon within a hydrogen-based model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hallam, Brett, E-mail: brett.hallam@unsw.edu.au; Abbott, Malcolm; Nampalli, Nitin

    2016-02-14

    A three-state model is used to explore the influence of defect formation- and passivation rates of carrier-induced degradation related to boron-oxygen complexes in boron-doped p-type silicon solar cells within a hydrogen-based model. The model highlights that the inability to effectively mitigate carrier-induced degradation at elevated temperatures in previous studies is due to the limited availability of defects for hydrogen passivation, rather than being limited by the defect passivation rate. An acceleration of the defect formation rate is also observed to increase both the effectiveness and speed of carrier-induced degradation mitigation, whereas increases in the passivation rate do not lead tomore » a substantial acceleration of the hydrogen passivation process. For high-throughput mitigation of such carrier-induced degradation on finished solar cell devices, two key factors were found to be required, high-injection conditions (such as by using high intensity illumination) to enable an acceleration of defect formation whilst simultaneously enabling a rapid passivation of the formed defects, and a high temperature to accelerate both defect formation and defect passivation whilst still ensuring an effective mitigation of carrier-induced degradation.« less

  2. Haemoglobin scavenging after subarachnoid haemorrhage.

    PubMed

    Durnford, A; Dunbar, J; Galea, J; Bulters, D; Nicoll, J A R; Boche, D; Galea, I

    2015-01-01

    Rapid and effective clearance of cell-free haemoglobin after subarachnoid haemorrhage (SAH) is important to prevent vasospasm and neurotoxicity and improve long-term outcome. Haemoglobin is avidly bound by haptoglobin, and the complex is cleared by CD163 expressed on the membrane surface of macrophages. We studied the kinetics of haemoglobin and haptoglobin in cerebrospinal fluid after SAH. We show that haemoglobin levels rise gradually after SAH. Haptoglobin levels rise acutely with aneurysmal rupture as a result of injection of blood into the subarachnoid space. Although levels decline as haemoglobin scavenging occurs, complete depletion of haptoglobin does not occur and levels start rising again, indicating saturation of CD163 sites available for haptoglobin-haemoglobin clearance. In a preliminary neuropathological study we demonstrate that meningeal CD163 expression is upregulated after SAH, in keeping with a proinflammatory state. However, loss of CD163 occurs in meningeal areas with overlying blood compared with areas without overlying blood. Becauses ADAM17 is the enzyme responsible for shedding membrane-bound CD163, its inhibition may be a potential therapeutic strategy after SAH.

  3. Design of a tissue oxygenation monitor and verification on human skin

    NASA Astrophysics Data System (ADS)

    Liu, Hongyuan; Kohl-Bareis, Matthias; Huang, Xiabing

    2011-07-01

    We report the design of a tissue oxygen and temperature monitor. The non-invasive, fibre based device monitors tissue haemoglobin (Hb) and oxygen saturation (SO2) and is based on white-light reflectance spectroscopy.Visible light with wavelengths in the 500 - 650nm range is utilized. The spectroscopic algorithm takes into account the tissue scattering and melanin absorption for the calculation of tissue haemoglobin concentration and oxygen saturation. The monitor can probe superficial layers of tissue with a high spatial resolution (mm3) and a high temporal resolution (40 Hz). It provides an accurate measurement with the accuracy of SO2 at 2 % and high reliability with less than 2 % variation of continuous SO2 measurement over 12 hours. It can also form a modular system when used in conjunction with a laser Doppler monitor, enabling simultaneous measurements of Hb, SO2 and blood flow. We found experimentally that the influence of the source-detector separation on the haemoglobin parameters is small. This finding is discussed by Monte Carlo simulations for the depth sensitivity profile. The influence of probe pressure and the skin pigmentation on the measurement parameters are assessed before in vivo experimental data is presented. The combination with laser Doppler flowmetry demonstrates the importance of a measurement of both the haemoglobin and the blood flow parameters for a full description of blood tissue perfusion. This is discussed in experimental data on human skin during cuff occlusion and after hyperemisation by a pharmacological cream. Strong correlation is observed between tissue oxygen (Hb and SO2) and blood flow measurements.

  4. Evaluation of haemoglobin (erythrogen): for improved somatic embryogenesis and plant regeneration in cotton (Gossypium hirsutum L. cv. SVPR 2).

    PubMed

    Ganesan, M; Jayabalan, N

    2004-10-01

    Somatic embryogenesis in cotton (Gossypium hirsutum L.) is accelerated when the plant regeneration medium is supplemented with haemoglobin (erythrogen). In cotton SVPR 2 lines, a higher frequency of embryoid formation was observed when the medium contained 400 mg/l haemoglobin. Fresh weight of the callus, rate of embryoid induction, number of embryoids formed and the percentage of plant regeneration from somatic embryos were increased. Among the two different cultivars tested, MCU 11 showed no response to the presence of haemoglobin when compared to SVPR 2, and embryogenic callus formation was completely absent in the former. Medium containing MS salts, 100 mg/l myo-inositol , 0.3 mg/l thiamine-HCL, 0.3 mg/l Picloram (PIC), 0.1 mg/l kinetin and 400 mg/l haemoglobin effected a better response with respect to embryogenic callus induction. After 8 weeks of culture, a high frequency of embryoid induction was observed on medium containing MS basal salts, 100 mg/l myo-inositol, 0.3 mg/l PIC , 0.1 mg/l isopentenyl adenine, 1.0 g/l NH4NO3 and 400 mg/l haemoglobin. Plant regeneration was observed in 75.8% of the mature somatic embryos, and whole plant regeneration was achieved within 6-7 months of culture. The regenerated plantlets were fertile and similar to in vivo-grown, seed-derived plants except that they were phenotypically smaller. A positive influence of haemoglobin was observed at concentrations up to 400 mg/l at all stages of somatic embryogenesis. The increase in the levels of antioxidant enzyme activities, for example superoxide dismutase and peroxidase, indicated the presence of excess oxygen uptake and the stressed condition of the plant tissues that arose from haemoglobin supplementation. This increased oxygen uptake and haemoglobin-mediated stress appeared to accelerate somatic embryogenesis in cotton.

  5. Classification of variant forms of haemoglobin according to the ratio of glycated haemoglobin to glycated albumin.

    PubMed

    Miyazaki, Ayako; Kohzuma, Takuji; Kasayama, Soji; Koga, Masafumi

    2012-09-01

    Asymptomatic variant haemoglobin is increasingly being found in the measurement of glycated haemoglobin (HbA(1c)) for the management of diabetes mellitus. We compared the HbA(1c) concentrations measured by high-performance liquid chromatography (HPLC) and immunoassay and glycated albumin (GA) concentrations and calculated the respective ratios in order to classify the variant haemoglobin. Twenty different haemoglobin variants from 43 subjects were identified by mass spectrometry and DNA analysis. Since GA accurately reflects glycaemic control in patients with variant haemoglobin, we calculated respective ratios of HbA(1c) and GA. Haemoglobin variants causing a low ratio of HbA(1c) measured by HPLC (HPLC-HbA(1c)) to GA with a normal ratio of HbA(1c) measured by immunoassay (IA-HbA(1c)) to GA were classified as C1. A further classification of α and β was used with abnormalities of the α chain or β chain in the haemoglobin gene. Other haemoglobin variants were classified as non-C1. Eight diabetic patients with stable glycaemic control were used as controls. Twenty forms of variant haemoglobins were classified as C1α (2 variants; I-Interlaken and Hb J-Meerut), C1β (15 variants) and non-C1 (3 variants; Hb Himeji, Hb Woolwich, Hb Peterborough). Positive correlations between GA and HPLC-HbA(1c) or IA-HbA(1c) were seen in the C1β patients with diabetes mellitus. The regression line between GA and HPLC-HbA(1c), but not that between GA and IA-HbA(1c), showed a downward shift in comparison with the data obtained from the diabetic controls. Variant haemoglobin could be classified by calculating the ratios of HPLC-HbA(1c), IA-HbA(1c) and GA.

  6. Haemoglobin responses to transfusion in severe iron deficiency anaemia: potential impact of gastrointestinal disorders.

    PubMed

    Bosch, X; Montori, E; Guerra-García, M; Costa-Rodríguez, J; Quintanilla, M H; Tolosa-Chapasian, P E; Moreno, P; Guasch, N; López-Soto, A

    2017-04-01

    Red blood cell (RBC) transfusion may be justified in iron deficiency anaemia (IDA) when an increase in oxygen delivery is needed, as sometimes occurs in subjects with haemoglobin <8·0 mg/dL, serious comorbidities or at risk of cardiovascular instability. Earlier investigations showed that some patients with severe IDA requiring transfusion had lower than expected post-transfusion haemoglobin levels with poorer clinical outcomes than other patients. After hypothesizing that haemoglobin responses to transfusion were different and that the underlying gastrointestinal (GI) disorders causing IDA could be a confounder explaining this association, these responses were analysed in a prospective cohort of IDA adults referred for outpatient GI investigation. Transfused patients with proven IDA, baseline haemoglobin at referral <9·0 g/dL and no extraintestinal bleeding were eligible. To assess a homogeneous population, only GI disorders known to cause occult bleeding were considered. Haemoglobin increments per 100 mL of RBCs were investigated. In total, 2818 patients were enrolled over 10·5 years. On multivariable regression, diffuse angiodysplasias and GI cancer independently predicted for reduced increments in post-transfusion haemoglobin [adjusted regression coefficients: -0·082 (95% confidence interval, -0·093 to -0·072) and -0·073 (95% confidence interval, -0·081 to -0·066), respectively, P < 0·001 in both]. Haemoglobin responses in the remaining bleeding disorders were adequate and agreed with the principle that one RBC unit increases the haemoglobin an average of 1 g/dL. The potential differential impact of GI disorders on changes in haemoglobin levels after RBC transfusion could be useful for transfusing physicians, especially for diagnostic purposes. © 2017 International Society of Blood Transfusion.

  7. Hb Potomac (101 Glu replaced by Asp): speculations on placental oxygen transport in carriers of high-affinity hemoglobins.

    PubMed

    Charache, S; Jacobson, R; Brimhall, B; Murphy, E A; Hathaway, P; Winslow, R; Jones, R; Rath, C; Simkovich, J

    1978-02-01

    Blood from a woman with unexplained erythrocytosis had increased oxygen affinity, but no abnormality could be detected by electrophoresis or chromatography of her hemolysate. Separation of the tryptic peptides of her beta chains disclosed two half-sized peaks in the regions of beta T-11. The faster of these was abnormal, with the structure beta 101 Glu replaced by Asp. The new hemoglobin was called "Potomac." Three of the proband's four surviving siblings and both of her children were carriers. Differences in the ratio of carrier: normal children born to male of female carriers of 23 other high-affinity hemoglobins were not significant. The high proportion of carriers in this kindred was probably due to chance alone, and not because high maternal oxygen affinity interfered with oxygen transport to fetuses with normal hemoglobin.

  8. Purification, crystallization and preliminary X-ray diffraction studies on avian haemoglobin from pigeon (Columba livia).

    PubMed

    Sathya Moorthy, Pon; Neelagandan, K; Balasubramanian, M; Ponnuswamy, M N

    2009-02-01

    Haemoglobin is a physiologically significant metalloprotein that is involved in the exchange of gases for sustaining life. The respiratory system of birds is unique and complex compared with that of mammals. Many investigations of avian haemoglobins have revealed the presence of inositol pentaphosphate (IP5), a principal allosteric effector that is involved in regulation of their function. Structural investigations of avian haemoglobins are presently not adequate to explain their function. Efforts have been made in this direction in order to understand the oxygen-binding affinity involved in adapting to hypoxia in avian haemoglobins. Fresh whole blood was collected from pigeon (Columba livia) and purified using a DEAE cellulose anion-exchange chromatographic column. Crystallization of pigeon haemoglobin was accomplished using the hanging-drop vapour-diffusion method using PEG 3350 as a precipitant in 50 mM sodium acetate buffer pH 5.5 with 1 M NaCl. Data collection was carried out using a MAR345 image-plate detector system. The crystals diffracted to 2 A resolution. Pigeon haemoglobin crystallizes in a triclinic space group, with two whole biological molecules in the asymmetric unit and with unit-cell parameters a = 55.005, b = 65.528, c = 104.370 A, alpha = 78.742, beta = 89.819, gamma = 65.320 degrees .

  9. High-performance liquid chromatographic separation of human haemoglobins. Simultaneous quantitation of foetal and glycated haemoglobins.

    PubMed

    Bisse, E; Wieland, H

    1988-12-29

    A high-performance liquid chromatographic system, which uses a weak cation exchanger (PolyCATA) together with Bis-Tris buffer (pH 6.47-7.0) and sodium acetate gradients, is described. Samples from adults and newborns were analysed and a clean separation of many minor and major normal and abnormal haemoglobin (Hb) variants was greatly improved. The method allows the separation of minor foetal haemoglobin (HbF) variants and the simultaneous quantitation of HbF and glycated HbA. HbF values correlated well with those obtained by the alkali denaturation method (r = 0.997). The glycated haemoglobin (HbAIc) levels measured in patients with high HbF concentrations correlated with the total glycated haemoglobin determined by bioaffinity chromatography (r = 0.973). The procedure is useful for diagnostic applications and affords an effective and sensitive way of examining blood samples for haemoglobin abnormalities.

  10. From the Arctic to fetal life: physiological importance and structural basis of an 'additional' chloride-binding site in haemoglobin.

    PubMed

    De Rosa, M Cristina; Castagnola, Massimo; Bertonati, Claudia; Galtieri, Antonio; Giardina, Bruno

    2004-06-15

    Haemoglobins from mammals of sub-Arctic and Arctic species, as well as fetal human Hb, are all characterized by a significantly lower Delta H of oxygenation compared with the majority of mammalian haemoglobins from temperate species (exceptions are represented by some cold-resistant species, such as cow, horse and pig). This has been interpreted as an adaptive mechanism of great importance from a physiological point of view. To date, the molecular basis of this thermodynamic characteristic is still not known. In the present study, we show that binding of extra chloride (with respect to adult human Hb) ions to Hb would significantly contribute to lowering the overall heat of oxygenation, thus providing a molecular basis for the low effect of temperature on the oxygenation-deoxygenation cycle. To this aim, the oxygen binding properties of bovine Hb, bear (Ursus arctos) Hb and horse Hb, which are representative of this series of haemoglobins, have been studied with special regard to the effect of heterotropic ligands, such as organic phosphates (namely 2,3-diphosphoglycerate) and chloride. Functional results are consistent with a mechanism for ligand binding that involves an additional binding site for chloride ion. Analysis of computational chemistry results, obtained by the GRID program, further confirm the hypothesis that the reason for the lower Delta H of oxygenation is mainly due to an increase in the number of the oxygen-linked chloride-binding sites.

  11. Effects of α-thalassaemia mutations on the haematological parameters of β-thalassaemia carriers.

    PubMed

    Saleh-Gohari, Nasrollah; Khademi Bami, Maryam; Nikbakht, Roya; Karimi-Maleh, Hassan

    2015-07-01

    Thalassaemia is a haemoglobin disorder caused by a reduction in, or a complete absence of, the production of α- or β-globin genes. Detection of β-thalassaemia carriers is the first step in the prenatal diagnosis of the disease and is based primarily on the differences between levels of blood cell indices. Since co-inheritance of β- and α-thalassaemia mutations modulates the haematological parameters of heterozygote β-thalassaemia indices, understanding the influence of this interaction is helpful for identification of disease carriers. To determine the effects of α-thalassaemia mutations on the haematological parameters of β-thalassaemia carriers. We used gap-PCR and amplification refractory mutation system techniques to find any α- and/or β-thalassaemia mutations in 270 subjects who were suspected to be thalassaemia carriers. The mean values of the haematological parameters in α, β-thalassaemia and β-thalassaemia carriers were compared. Significant differences in mean corpuscular volume (MCV), mean corpuscular haemoglobin (MCH) and HbA2 were found between the two groups. Patients who were α, β-thalassaemia carriers had higher mean values of MCV and MCH, whereas HbA2 levels were higher in simple β-thalassaemia. No marked differences were found in mean cell haemoglobin (Hb) concentration and Hb blood cell indices. The value of MCV, MCH and HbA2 were significantly different between α,β-thalassaemia and simple β-thalassaemia in men and women, but the mean values of Hb in the two groups differed markedly only in men. We conclude that co-inheritance of α- and β-thalassaemia mutations may result in misdiagnosis of β-thalassaemia carriers. Therefore, in genetic counselling of patients with a near-normal range of blood cell indices the possibility that they may carry α, β-thalassaemia mutations must be considered. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. In vivo biodistribution and oxygenation potential of a new generation of oxygen carrier.

    PubMed

    Le Gall, Tony; Polard, Valérie; Rousselot, Morgane; Lotte, Auréline; Raouane, Mouna; Lehn, Pierre; Opolon, Paule; Leize, Elisabeth; Deutsch, Eric; Zal, Franck; Montier, Tristan

    2014-10-10

    Natural giant extracellular hemoglobins (Hbs) from polychaete annelids are currently actively investigated as promising oxygen carriers. Their powerful oxygenating ability and their safety have been demonstrated in preclinical studies, motivating their development for therapeutic and industrial applications. HEMARINA-M101 (M101) is derived from the marine invertebrate Arenicola marina. It is formulated as a manufactured product designated HEMOXYCarrier(®) (HEMARINA SA, France). The aim of the present study was to unveil the fate of M101 after a single intravenous (i.v.) injection in mice. For this purpose, M101 was tagged with a far-red fluorescent dye. Repeated non-invasive fluorescent imaging revealed a rapid diffusion of M101 in the whole body of animals, reaching all the examined organs such as brain, liver, lungs and ovaries. Functional M101 was circulating in bloodstream for several hours, without inducing any obvious side-effects. Last, a single i.v. injection of M101 in mice bearing human-derived subcutaneous tumors demonstrated the ability of this Hb to reduce hypoxia in poorly vascularized tissues, thus supporting the biological relevance of M101 oxygen release to vertebrate tissues. Altogether, these results further encourage the development of M101 as an oxygen carrying therapeutic. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Establishing traceability of photometric absorbance values for accurate measurements of the haemoglobin concentration in blood

    NASA Astrophysics Data System (ADS)

    Witt, K.; Wolf, H. U.; Heuck, C.; Kammel, M.; Kummrow, A.; Neukammer, J.

    2013-10-01

    Haemoglobin concentration in blood is one of the most frequently measured analytes in laboratory medicine. Reference and routine methods for the determination of the haemoglobin concentration in blood are based on the conversion of haeme, haemoglobin and haemiglobin species into uniform end products. The total haemoglobin concentration in blood is measured using the absorbance of the reaction products. Traceable absorbance measurement values on the highest metrological level are a prerequisite for the calibration and evaluation of procedures with respect to their suitability for routine measurements and their potential as reference measurement procedures. For this purpose, we describe a procedure to establish traceability of spectral absorbance measurements for the haemiglobincyanide (HiCN) method and for the alkaline haematin detergent (AHD) method. The latter is characterized by a higher stability of the reaction product. In addition, the toxic hazard of cyanide, which binds to the iron ion of the haem group and thus inhibits the oxygen transport, is avoided. Traceability is established at different wavelengths by applying total least-squares analysis to derive the conventional quantity values for the absorbance from the measured values. Extrapolation and interpolation are applied to get access to the spectral regions required to characterize the Q-absorption bands of the HiCN and AHD methods, respectively. For absorbance values between 0.3 and 1.8, the contributions of absorbance measurements to the total expanded uncertainties (95% level of confidence) of absorbance measurements range from 1% to 0.4%.

  14. Purification, crystallization and preliminary X-ray diffraction studies on avian haemoglobin from pigeon (Columba livia)

    PubMed Central

    Sathya Moorthy, Pon.; Neelagandan, K.; Balasubramanian, M.; Ponnuswamy, M. N.

    2009-01-01

    Haemoglobin is a physiologically significant metalloprotein that is involved in the exchange of gases for sustaining life. The respiratory system of birds is unique and complex compared with that of mammals. Many investigations of avian haemoglobins have revealed the presence of inositol pentaphosphate (IP5), a principal allosteric effector that is involved in regulation of their function. Structural investigations of avian haemoglobins are presently not adequate to explain their function. Efforts have been made in this direction in order to understand the oxygen-binding affinity involved in adapting to hypoxia in avian haemoglobins. Fresh whole blood was collected from pigeon (Columba livia) and purified using a DEAE cellulose anion-exchange chromatographic column. Crystallization of pigeon haemoglobin was accomplished using the hanging-drop vapour-diffusion method using PEG 3350 as a precipitant in 50 mM sodium acetate buffer pH 5.5 with 1 M NaCl. Data collection was carried out using a MAR345 image-plate detector system. The crystals diffracted to 2 Å resolution. Pigeon haemoglobin crystallizes in a triclinic space group, with two whole biological molecules in the asymmetric unit and with unit-cell parameters a = 55.005, b = 65.528, c = 104.370 Å, α = 78.742, β = 89.819, γ = 65.320°. PMID:19194000

  15. Strategies for Small Volume Resuscitation: Hyperosmotic-Hyperoncotic Solutions, Hemoglobin Based Oxygen Carriers and Closed-Loop Resuscitation

    NASA Technical Reports Server (NTRS)

    Kramer, George C.; Wade, Charles E.; Dubick, Michael A.; Atkins, James L.

    2004-01-01

    Introduction: Logistic constraints on combat casualty care preclude traditional resuscitation strategies which can require volumes and weights 3 fold or greater than hemorrhaged volume. We present a review of quantitative analyses of clinical and animal data on small volume strategies using 1) hypertonic-hyperosmotic solutions (HHS); 2) hemoglobin based oxygen carriers (HBOCs) and 3) closed-loop infusion regimens.Methods and Results: Literature searches and recent queries to industry and academic researchers have allowed us to evaluate the record of 81 human HHS studies (12 trauma trials), 19 human HBOCs studies (3trauma trials) and two clinical studies of closed-loop resuscitation.There are several hundreds animal studies and at least 82 clinical trials and reports evaluating small volume7.2%-7.5% hypertonic saline (HS) most often combined with colloids, e.g., dextran (HSD) or hetastarch(HSS). HSD and HSS data has been published for 1,108 and 392 patients, respectively. Human studies have documented volume sparing and hemodynamic improvements. Meta-analyses suggest improved survival for hypotensive trauma patients treated with HSD with significant reductions in mortality found for patients with blood pressure < 70 mmHg, head trauma, and penetrating injury requiring surgery. HSD and HSS have received regulatory approval in 14 and 3 countries, respectively, with 81,000+ units sold. The primary reported use was head injury and trauma resuscitation. Complications and reported adverse events are surprisingly rare and not significantly different from other solutions.HBOCs are potent volume expanders in addition to oxygen carriers with volume expansion greater than standard colloids. Several investigators have evaluated small volume hyperoncotic HBOCs or HS-HBOC formulations for hypotensive and normotensive resuscitation in animals. A consistent finding in resuscitation with HBOCs is depressed cardiac output. There is some evidence that HBOCs more efficiently unload

  16. Augmenting the antibiofilm efficacy of advanced noninvasive light activated disinfection with emulsified oxidizer and oxygen carrier.

    PubMed

    George, Saji; Kishen, Anil

    2008-09-01

    In this study, we tested the hypothesis that the inclusion of an oxidizer and oxygen carrier in the photosensitization formulation would facilitate comprehensive disinfection of matured endodontic biofilm by light-activated disinfection (LAD). Photosensitizing formulations containing methylene blue (MB) and an oxygen carrier alone (perfluorodecahydronaphthalene) (PF1) or in combination with oxidizer (H(2)O(2)) (PF2) or their emulsions formed with triton-X100 (Bio-Rad Laboratories, Hercules, CA) in different proportions (PF3 and PF4) were tested for photochemical properties and damage to the biofilm structure using confocal laser scanning microscopy. Conventional chemomechanical preparation, LAD using MB in water, and LAD using MB in emulsion (PF4) were also conducted on 10-week-old Enterococcus faecalis biofilm within root canals. MB in emulsion (PF4) was overall the most effective photosensitizer formulation for photooxidation, generation of singlet oxygen (p = 0.001), and in disinfecting biofilm bacteria. Advanced noninvasive LAD using a photosensitizer formulation containing oxidizer and oxygen carrier disrupted the biofilm matrix and facilitated comprehensive inactivation of biofilm bacteria. This modified photosensitizer formulation will have potential advantages in endodontic disinfection.

  17. First reported case of Haemoglobin-M Hyde Park in a Malay family living in Malaysia.

    PubMed

    Loong, Tang Yee; Chong, Doris Lau Sie; Jamal, A Rahman A; Murad, Nor Azian Abdul; Sabudin, Raja Zahratul Azma Raja; Fun, Leong Chooi

    2016-01-01

    Haemoglobin (Hb)-M Hyde Park, also known as Hb-M Akita is a rare type of hereditary Hb M due to autosomal dominant mutation of CAC>TAC on codon 92 of β globin gene resulting in the replacement of histidine by tyrosine on β globin chain. This variant Hb has a tendency to form methaemoglobin (metHb). The iron ion in metHb is oxidized to ferric (Fe3+) which is unable to carry oxygen and the patients manifest as cyanosis clinically. A 9-year-old Malay girl was incidentally found to be cyanotic when she presented to a health clinic. Laboratory investigations revealed raised methaemoglobin levels and Hb analysis findings were consistent with Hb-M Hyde Park. β gene sequencing confirmed a point mutation of CAC>TAC on codon 92 in one of the β genes. The family study done on the individuals with cyanosis showed similar findings. A diagnosis of heterozygous Hb-M Hyde Park was made. Patients with this variant Hb usually presented with cyanosis with mild haemolysis and maybe misdiagnosed as congenital heart disease. No further treatment is needed as patients are relatively asymptomatic. Although the disease is harmless in the heterozygous carriers but the offspring of the carriers may suffer severe haemolytic anaemia when the offspring also inherit other β haemoglobinopathies/thalassemia. This can happen due to high prevalence of β thalassemia carrier (3.5-4 %) found in Malaysia. At the time of writing, this is the first case of hereditary Hb-M Hyde Park diagnosed in a Malay family living in Malaysia.

  18. Haemoglobin function in vertebrates: evolutionary changes in cellular regulation in hypoxia.

    PubMed

    Nikinmaa, M

    2001-11-15

    The evolution of erythrocytic hypoxia responses is reviewed by comparing the cellular control of haemoglobin-oxygen affinity in agnathans, teleost fish and terrestrial vertebrates. The most ancient response to hypoxic conditions appears to be an increase in cell volume, which increases the haemoglobin-oxygen affinity in lampreys. In teleost fish, an increase of cell volume in hypoxic conditions is also evident. The volume increase is coupled to an increase in erythrocyte pH. These changes are caused by an adrenergic activation of sodium/proton exchange across the erythrocyte membrane. The mechanism is important in acute hypoxia and is followed by a decrease in cellular adenosine triphosphate (ATP) and guanosine triphosphate (GTP) concentrations in continued hypoxia. In hypoxic bird embryos, the ATP levels are also reduced. The mechanisms by which hypoxia decreases cellular ATP and GTP concentrations remains unknown, although at least in bird embryos cAMP-dependent mechanisms have been implicated. In mammals, hypoxia responses appear to occur mainly via modulation of cellular organic phosphate concentrations. In moderate hypoxia, 2,3-diphosphoglycerate levels are increased as a result of alkalosis caused by increased ventilation.

  19. Hemoglobin-Based Oxygen Carrier (HBOC) Development in Trauma: Previous Regulatory Challenges, Lessons Learned, and a Path Forward.

    PubMed

    Keipert, Peter E

    2017-01-01

    Historically, hemoglobin-based oxygen carriers (HBOCs) were being developed as "blood substitutes," despite their transient circulatory half-life (~ 24 h) vs. transfused red blood cells (RBCs). More recently, HBOC commercial development focused on "oxygen therapeutic" indications to provide a temporary oxygenation bridge until medical or surgical interventions (including RBC transfusion, if required) can be initiated. This included the early trauma trials with HemAssist ® (BAXTER), Hemopure ® (BIOPURE) and PolyHeme ® (NORTHFIELD) for resuscitating hypotensive shock. These trials all failed due to safety concerns (e.g., cardiac events, mortality) and certain protocol design limitations. In 2008 the Food and Drug Administration (FDA) put all HBOC trials in the US on clinical hold due to the unfavorable benefit:risk profile demonstrated by various HBOCs in different clinical studies in a meta-analysis published by Natanson et al. (2008). During standard resuscitation in trauma, organ dysfunction and failure can occur due to ischemia in critical tissues, which can be detected by the degree of lactic acidosis. SANGART'S Phase 2 trauma program with MP4OX therefore added lactate >5 mmol/L as an inclusion criterion to enroll patients who had lost sufficient blood to cause a tissue oxygen debt. This was key to the successful conduct of their Phase 2 program (ex-US, from 2009 to 2012) to evaluate MP4OX as an adjunct to standard fluid resuscitation and transfusion of RBCs. In 2013, SANGART shared their Phase 2b results with the FDA, and succeeded in getting the FDA to agree that a planned Phase 2c higher dose comparison study of MP4OX in trauma could include clinical sites in the US. Unfortunately, SANGART failed to secure new funding and was forced to terminate development and operations in Dec 2013, even though a regulatory path forward with FDA approval to proceed in trauma had been achieved.

  20. Highly Efficient Oxygen-Storage Material with Intrinsic Coke Resistance for Chemical Looping Combustion-Based CO2 Capture.

    PubMed

    Imtiaz, Qasim; Kurlov, Alexey; Rupp, Jennifer Lilia Marguerite; Müller, Christoph Rüdiger

    2015-06-22

    Chemical looping combustion (CLC) and chemical looping with oxygen uncoupling (CLOU) are emerging thermochemical CO2 capture cycles that allow the capture of CO2 with a small energy penalty. Here, the development of suitable oxygen carrier materials is a key aspect to transfer these promising concepts to practical installations. CuO is an attractive material for CLC and CLOU because of its high oxygen-storage capacity (20 wt %), fast reaction kinetics, and high equilibrium partial pressure of oxygen at typical operating temperatures (850-1000 °C). However, despite its promising characteristics, its low Tammann temperature requires the development of new strategies to phase-stabilize CuO-based oxygen carriers. In this work, we report a strategy based on stabilization by co-precipitated ceria (CeO2-x ), which allowed us to increase the oxygen capacity, coke resistance, and redox stability of CuO-based oxygen carriers substantially. The performance of the new oxygen carriers was evaluated in detail and compared to the current state-of-the-art materials, that is, Al2 O3 -stabilized CuO with similar CuO loadings. We also demonstrate that the higher intrinsic oxygen uptake, release, and mobility in CeO2-x -stabilized CuO leads to a three times higher carbon deposition resistance compared to that of Al2 O3 -stabilized CuO. Moreover, we report a high cyclic stability without phase intermixing for CeO2-x -supported CuO. This was accompanied by a lower reduction temperature compared to state-of-the-art Al2 O3 -supported CuO. As a result of its high resistance towards carbon deposition and fast oxygen uncoupling kinetics, CeO2-x -stabilized CuO is identified as a very promising material for CLC- and CLOU-based CO2 capture architectures. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Analysis of Mitochondrial haemoglobin in Parkinson's disease brain.

    PubMed

    Shephard, Freya; Greville-Heygate, Oliver; Liddell, Susan; Emes, Richard; Chakrabarti, Lisa

    2016-07-01

    Mitochondrial dysfunction is an early feature of neurodegeneration. We have shown there are mitochondrial haemoglobin changes with age and neurodegeneration. We hypothesised that altered physiological processes are associated with recruitment and localisation of haemoglobin to these organelles. To confirm a dynamic localisation of haemoglobin we exposed Drosophila melanogaster to cyclical hypoxia with recovery. With a single cycle of hypoxia and recovery we found a relative accumulation of haemoglobin in the mitochondria compared with the cytosol. An additional cycle of hypoxia and recovery led to a significant increase of mitochondrial haemoglobin (p<0.05). We quantified ratios of human mitochondrial haemoglobin in 30 Parkinson's and matched control human post-mortem brains. Relative mitochondrial/cytosolic quantities of haemoglobin were obtained for the cortical region, substantia nigra and cerebellum. In age matched post-mortem brain mitochondrial haemoglobin ratios change, decreasing with disease duration in female cerebellum samples (n=7). The change is less discernible in male cerebellum (n=18). In cerebellar mitochondria, haemoglobin localisation in males with long disease duration shifts from the intermembrane space to the outer membrane of the organelle. These new data illustrate dynamic localisation of mitochondrial haemoglobin within the cell. Mitochondrial haemoglobin should be considered in the context of gender differences characterised in Parkinson's disease. It has been postulated that cerebellar circuitry may be activated to play a protective role in individuals with Parkinson's. The changing localisation of intracellular haemoglobin in response to hypoxia presents a novel pathway to delineate the role of the cerebellum in Parkinson's disease. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Effects of Hemopure on maximal oxygen uptake and endurance performance in healthy humans.

    PubMed

    Ashenden, M J; Schumacher, Y O; Sharpe, K; Varlet-Marie, E; Audran, M

    2007-05-01

    Haemoglobin-based oxygen carriers (HBOCs) such as Hemopure are touted as a tenable substitute for red blood cells and therefore potential doping agents, although the mechanisms of oxygen transport of HBOCs are incompletely understood. We investigated whether infusion of Hemopure increased maximal oxygen uptake (V.O 2max) and endurance performance in healthy subjects. Twelve male subjects performed two 4-minute submaximal exercise bouts equivalent to 60 % and 75 % of V.O (2max) on a cycle ergometer, followed by a ramped incremental protocol to elicit V.O (2max). A crossover design tested the effect of infusing either 30 g (6 subjects) or 45 g (6 subjects) of Hemopure versus a placebo. Under our study conditions, Hemopure did not increase V.O (2max) nor endurance performance. However, the infusion of Hemopure caused a decrease in heart rate of approximately 10 bpm (p=0.009) and an average increase in mean ( approximately 7 mmHg) and diastolic blood pressure ( approximately 8 mmHg) (p=0.046) at submaximal and maximal exercise intensities. Infusion of Hemopure did not bestow the same physiological advantages generally associated with infusion of red blood cells. It is conceivable that under exercise conditions, the hypertensive effects of Hemopure counter the performance-enhancing effect of improved blood oxygen carrying capacity.

  3. HEMORHEOLOGICAL IMPLICATIONS OF PERFLUOROCARBON BASED OXYGEN CARRIER INTERACTION WITH COLLOID PLASMA EXPANDERS AND BLOOD

    PubMed Central

    Vásquez, Diana M.; Ortiz, Daniel; Alvarez, Oscar A.; Briceño, Juan C.; Cabrales, Pedro

    2013-01-01

    Perfluorocarbon (PFC) emulsion based oxygen carriers lack colloid osmotic pressure (COP) and must be administered with colloid-based plasma expanders (PEs). Although PFC emulsions have been widely studied, there is limited information about PFC emulsion interaction with PEs and blood. Their interaction forms aggregates due to electrostatic and rheological phenomena, and change blood rheology and blood flow. This study analyzes the effects of the interaction between PFC emulsions with blood in the presence of clinically-used PEs. The rheological behavior of the mixtures was analyzed in parallel with in vivo analysis of blood flow in microvessels using intravital microscopy when administered in a clinically relevant scenario. The interaction between the PFC emulsion and PE with blood produced PFC droplets and red blood cell (RBCs) aggregation, and increased blood viscosity. The PFC droplets formed aggregates when mixed with PEs containing electrolytes, and the aggregation increased with the electrolyte concentration. Mixtures of PFC with PEs that produced PFC aggregates also induced RCBs aggregation when mixed with blood, increasing blood viscosity at low shear rates. The more viscous suspension at low shear rates produced a blunted blood flow velocity profile in vivo relative to non-aggregating mixtures of PFC and PEs. For the PEs evaluated, albumin produced minimal to undetectable aggregation. PFC and PEs interaction with blood can affect sections of the microcirculation with low shear rate (e.g. arterioles, venules, and pulmonary circulation) because aggregates could cause capillary occlusion, decrease perfusion, pulmonary emboli, or focal ischemia. PMID:23606592

  4. New technology increases perioperative haemoglobin levels for paediatric cardiopulmonary bypass: what is the benefit?

    PubMed

    Thuys, Clarke; Horton, Stephen; Bennett, Martin; Augustin, Simon

    2006-01-01

    Increasing perioperative haemoglobin level by reducing priming volume and maintaining a safe cardiopulmonary bypass (CPB) system is the aim of every perfusionist. In this study, we have compared the two membrane oxygenators and pump systems used for paediatric bypass at the Royal Children's Hospital on a regular basis since 1988. We looked at all patients who had the Cobe VPCML (Cobe Laboratories, Denver, CO, USA) and Terumo RX-05 (Terumo Corporation, Tokyo, Japan) oxygenators used for flows from 800 mL/min up to the maximum rated flow for the respective oxygenator from January 2002 until March 2004. The VPCML refers to using only the 0.4-m2 section of the oxygenator. The pump systems used were the Stöckert CAPS (Stöckert Instrumente GmbH, Munich, Germany) and Jostra HL 30 (Jostra AB, Lund, Sweden). Changing from the VPCML to the RX-05 resulted in a 37% reduction in priming volume. The introduction of the Jostra HL 30 with a custom-designed mast system reduced the priming volume by another 15%. This change in priming volume allowed a significant increase, from 6 to 34%, in the percentage of patients who received bloodless primes, and for those patients who received blood primes, an increase in haemoglobin (Hb) on bypass from 8.2 to 9.6 g/dL, on average.

  5. Coencapsulation of oxygen carriers and glucose oxidase in polyelectrolyte complex capsules for the enhancement of D-gluconic acid and delta-gluconolactone production.

    PubMed

    Bucko, Marek; Gemeiner, Peter; Vikartovská, Alica; Mislovicová, Danica; Lacík, Igor; Tkác, Ján

    2010-04-01

    A novel encapsulated oxidative biocatalyst comprising glucose oxidase (GOD) coencapsulated with oxygen carriers within polyelectrolyte complex capsules was developed for the production of D-gluconic acid and delta-gluconolactone. The capsules containing immobilized GOD were produced by polyelectrolyte complexation with sodium alginate (SA) and cellulose sulfate (CS) as polyanions, poly(methylene-co-guanidine) (PMCG) as the polycation, CaCl(2) as the gelling agent and NaCl as the antigelling agent (GOD-SA-CS/PMCG capsules). Poly(dimethylsiloxane) (PDMS) and an emulsion of n-dodecane (DOD) or perfluorodecaline (PFD) with PDMS were used as the oxygen carriers and MnO(2) was used as a hydrogen peroxide decomposition catalyst. Water-soluble PDMS was found to act as both an oxygen carrier and an emulsifier of water-insoluble DOD and PFD. Stable microcapsules could be produced with concentrations of up to 4% (w/w) of PDMS, 10% (w/w) of DOD and PFD, and 25% (w/w) of MnO(2) in the polyanion solution of SA and CS. Roughly a two-fold increase in the GOD activity from 21.0+/-1.1 to 38.4+/-2.0 U*g(-1) and product space-time yields (STY) from 44.3+/-2.0 to 83.4+/-3.4 g*H*day(-1) could be achieved utilizing coencapsulated oxygen carriers compared to GOD encapsulated in the absence of oxygen carriers. This enhanced production does not significantly depend on the selected oxygen carrier under the conditions used in this study.

  6. Purification, crystallization, preliminary X-ray diffraction and molecular-replacement studies of great cormorant (Phalacrocorax carbo) haemoglobin.

    PubMed

    Jagadeesan, G; Malathy, P; Gunasekaran, K; Harikrishna Etti, S; Aravindhan, S

    2014-11-01

    Haemoglobin is the iron-containing oxygen-transport metalloprotein that is present in the red blood cells of all vertebrates. In recent decades, there has been substantial interest in attempting to understand the structural basis and functional diversity of avian haemoglobins. Towards this end, purification, crystallization, preliminary X-ray diffraction and molecular-replacement studies have been carried out on cormorant (Phalacrocorax carbo) haemoglobin. Crystals were grown by the hanging-drop vapour-diffusion method using PEG 3350, NaCl and glycerol as precipitants. The crystals belonged to the trigonal system P3₁21, with unit-cell parameters a=b=55.64, c=153.38 Å, β=120.00°; a complete data set was collected to a resolution of 3.5 Å. Matthews coefficient analysis indicated that the crystals contained a half-tetramer in the asymmetric unit.

  7. Paradoxical correlation between signal in functional magnetic resonance imaging and deoxygenated haemoglobin content in capillaries: a new theoretical explanation

    NASA Astrophysics Data System (ADS)

    Yamamoto, Toru; Kato, Toshinori

    2002-04-01

    Signal increases in functional magnetic resonance imaging (fMRI) are believed to be a result of decreased paramagnetic deoxygenated haemoglobin (deoxyHb) content in the neural activation area. However, discrepancies in this canonical blood oxygenation level dependent (BOLD) theory have been pointed out in studies using optical techniques, which directly measure haemoglobin changes. To explain the discrepancies, we developed a new theory bridging magnetic resonance (MR) signal and haemoglobin changes. We focused on capillary influences, which have been neglected in most previous fMRI studies and performed a combined fMRI and near-infrared spectroscopy (NIRS) study using a language task. Paradoxically, both the MR signal and deoxyHb content increased in Broca's area. On the other hand, fMRI activation in the auditory area near large veins correlated with a mirror-image decrease in deoxyHb and increase in oxygenated haemoglobin (oxyHb), in agreement with canonical BOLD theory. All fMRI signal changes correlated consistently with changes in oxyHb, the diamagnetism of which is insensitive to MR. We concluded that the discrepancy with the canonical BOLD theory is caused by the fact that the BOLD theory ignores the effect of the capillaries. Our theory explains the paradoxical phenomena of the oxyHb and deoxyHb contributions to the MR signal and gives a new insight into the precise haemodynamics of activation by analysing fMRI and NIRS data.

  8. Sickle haemoglobin, haemoglobin C and malaria mortality feedbacks.

    PubMed

    Gonçalves, Bronner P; Gupta, Sunetra; Penman, Bridget S

    2016-01-12

    Sickle haemoglobin (HbS) and haemoglobin C (HbC) are both caused by point mutations in the beta globin gene, and both offer substantial malaria protection. Despite the fact that the blood disorder caused by homozygosity for HbC is much less severe than that caused by homozygosity for HbS (sickle cell anaemia), it is the sickle mutation which has come to dominate many old-world malarious regions, whilst HbC is highly restricted in its geographical distribution. It has been suggested that this discrepancy may be due to sickle cell heterozygotes enjoying a higher level of malaria protection than heterozygotes for HbC. A higher fitness of sickle cell heterozygotes relative to HbC heterozygotes could certainly have allowed the sickle cell allele to spread more rapidly. However, observations that carrying either HbC or HbS enhances an individual's capacity to transmit malaria parasites to mosquitoes could also shed light on this conundrum. A population genetic model was used to investigate the evolutionary consequences of the strength of malaria selection being correlated with either HbS frequency or HbC frequency. If the selection pressure from malaria is positively correlated with the frequency of either HbS or HbC, it is easier for HbS to succeed in the competitive interaction between the two alleles. A feedback process whereby the presence of variant haemoglobins increases the level of malaria selection in a population could have contributed to the global success of HbS relative to HbC, despite the former's higher blood disorder cost.

  9. Topical haemoglobin spray for diabetic foot ulceration.

    PubMed

    Bateman, Sharon Dawn

    The development and subsequent deterioration of diabetic foot ulceration (DFU) is a common occurrence across all healthcare divides, concerning all patient groups, age, gender and social environments. It increases demand on clinical resources and creates unnecessary hardship for patients. Chronic DFU is challenging to prevent and notoriously difficult to manage owing to the complex nature of the patient and the disease itself. The improvement of oxygenation to many chronic wound groups is gaining momentum across wound care; particularly in those wounds such as DFU that present with circulatory, oxygen-deficient scenarios. A descriptive evaluation was undertaken in an acute clinical setting where a spray solution containing purified haemoglobin was used in a cohort of 20 patients who presented with chronic (>12 weeks) DFU. Standard wound care was undertaken by 18 health professionals with no changes to products, devices or practice before evaluation. All wounds received the addition of the product on eight set occasions over a 4-week period and the resulting data correlated in regards to the set outcomes of wound surface area reduction, ease of use, adverse events and patient acceptability. At 4 weeks all wounds had demonstrated positive wound reduction, there were no adverse events, all patients and clinicians found the product acceptable and easy to use. Interestingly, although not a set outcome, all wounds commenced the evaluation with wound-bed slough present and at 4 weeks 100% were deemed slough free. At a further 4-week review no patients wounds had regressed. The incorporation of a haemoglobin spray solution within this cohort of DFU resulted in a positive improvement in wound healing and slough elimination. Further work in this area is recommended to increase the evidence.

  10. Characterization of nano-bubbles as an oxygen carrier for in-situ bioremediation of organic pollutants in the subsurface

    NASA Astrophysics Data System (ADS)

    KIM, E.; Jung, J.; Kang, S.; Choi, Y.

    2016-12-01

    In-situ bioremediation using bubbles as an oxygen carrier has shown its applicability for aerobic biodegradation of organic pollutants in the subsurface. By recent progresses, generation of nano-sized bubbles is possible, which have enhanced oxygen transfer efficiencies due to their high interfacial area and stability. We are developing an in-situ bioremediation technique using nano-bubbles as an oxygen carrier. In this study, nano-bubbles were characterized for their size and oxygen supply capacity. Nano-bubbles were generated with pure oxygen and pure helium gas. The stable nano-bubbles suspended in water were sonicated to induce the bubbles to coalesce, making them to rise and be released out of the water. By removing the bubbles, the water volume was decreased by 0.006%. The gas released from the bubble suspension was collected to measure the amount of gas in the nano-bubbles. For sparingly soluble helium gas 17.9 mL/L was released from the bubble suspension, while for oxygen 46.2 mL/L was collected. For the oxygen nano-bubble suspension, it is likely that the release of dissolved oxygen (DO) contributed to the collected gas volume. After removing the oxygen nano-bubbles, 36.0 mg/L of DO was still present in water. Altogether, the oxygen nano-bubble suspension was estimated to have 66.2 mg/L of oxygen in a dissolved form and 25.6 mg/L as nano-bubbles. A high DO level in the water was possible because of their large Laplace pressure difference across the fluid interface. Applying Young-Laplace equation and ideal gas law, the bubble diameter was estimated to be approximately 10 nm, having an internal pressure of 323 atm. Considering the saturation DO of 8.26 mg/L for water in equilibrium with the atmosphere, the total oxygen content of 91.8 mg/L in the nano-bubble suspension suggests its great potential as an oxygen carrier. Studies are underway to verify the enhanced aerobic biodegradation of organic pollutants in soils by injecting nano-bubble suspensions.

  11. Relationship between changes in haemoglobin mass and maximal oxygen uptake after hypoxic exposure.

    PubMed

    Saunders, Philo U; Garvican-Lewis, Laura A; Schmidt, Walter F; Gore, Christopher J

    2013-12-01

    Endurance athletes have been using altitude training for decades to improve near sea-level performance. The predominant mechanism is thought to be accelerated erythropoiesis increasing haemoglobin mass (Hb(mass)) resulting in a greater maximal oxygen uptake (VO₂(max)). Not all studies have shown a proportionate increase in VO₂(max) as a result of increased Hb(mass). The aim of this study was to determine the relationship between the two parameters in a large group of endurance athletes after altitude training. 145 elite endurance athletes (94 male and 51 female) who participated in various altitude studies as altitude or control participants were used for the analysis. Participants performed Hb(mass) and VO₂(max) testing before and after intervention. For the pooled data, the correlation between per cent change in Hb(mass) and per cent change in VO₂(max) was significant (p<0.0001, r(2)=0.15), with a slope (95% CI) of 0.48 (0.30 to 0.67) intercept free to vary and 0.62 (0.46 to 0.77) when constrained through the origin. When separated, the correlations were significant for the altitude and control groups, with the correlation being stronger for the altitude group (slope of 0.57 to 0.72). With high statistical power, we conclude that altitude training of endurance athletes will result in an increase in VO₂(max) of more than half the magnitude of the increase in Hb(mass), which supports the use of altitude training by athletes. But race performance is not perfectly related to relative VO₂(max), and other non-haematological factors altered from altitude training, such as running economy and lactate threshold, may also be beneficial to performance.

  12. New porcine test-model reveals remarkable differences between algorithms for spectrophotometrical haemoglobin saturation measurements with VLS.

    PubMed

    Gade, John; Greisen, Gorm

    2016-09-01

    The study created an 'ex vivo' model to test different algorithms for measurements of mucosal haemoglobin saturation with visible light spectrophotometry (VLS). The model allowed comparison between algorithms, but it also allowed comparison with co-oximetry using a 'gold standard' method. This has not been described before. Seven pigs were used. They were perfused with cold Haemaxel, and thus killed, chilled and becoming bloodless. The bronchial artery was perfused with cold blood with known saturation and spectrophotometrical measurements were made through a bronchoscope. Based on 42 spectrophotometrical measurements of porcine bronchial mucosa saturation with fully oxygenated blood and 21 with de-oxygenated blood, six algorithms were applied to the raw-spectra of the measurements and compared with co-oxymetry. The difference from co-oxymetry in the oxygenated and de-oxygenated state ranged from  -32.8 to  +29.9 percentage points and from  -5.0 to  +9.2 percentage points, respectively. the algorithms showed remarkable in-between differences when tested on raw-spectra from an 'ex vivo' model. All algorithms had bias, more marked at high oxygenation than low oxygenation. Three algorithms were dis-recommended.

  13. Cell-free oxygen carriers: scientific foundations, clinical development, and new directions.

    PubMed

    Winslow, Robert M

    2008-10-01

    The most significant hurdle to the development of a safe and effective hemoglobin-based oxygen carrier ("blood substitute") is generally thought to be its propensity to cause vasoconstriction in the microcirculation and hypertension. Two theories for this effect are currently being studied: in one, scavenging NO by hemoglobin reduces vasorelaxation; in the other, cell-free hemoglobin oversupplies O2 (a known vasoconstrictor) to vascular walls by facilitated diffusion. While both mechanisms might lead to reduction of local NO concentration, the important distinction between the two is that if the NO scavenging theory is correct, it greatly diminishes the prospects to develop any solution based on free hemoglobin. However, if the O2-oversupply theory is correct, modifications to the hemoglobin molecule can be envisioned that can prevent oversupply and reduce toxicity. This review summarizes the development of Hemospan, a novel modification of human hemoglobin whose design is based on the O2-oversupply theory. Because of its low P50 and increased molecular size, the release of O2 in resistance vessels (arterioles) by Hemospan is restricted, and vasoconstriction is greatly reduced.

  14. Purification, crystallization, preliminary X-ray diffraction and molecular-replacement studies of great cormorant (Phalacrocorax carbo) haemoglobin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jagadeesan, G.; Malathy, P.; Gunasekaran, K.

    2014-10-25

    The great cormorant hemoglobin has been isolated, purified and crystallized and the three dimensional structure is solved using molecular replacement technique. Haemoglobin is the iron-containing oxygen-transport metalloprotein that is present in the red blood cells of all vertebrates. In recent decades, there has been substantial interest in attempting to understand the structural basis and functional diversity of avian haemoglobins. Towards this end, purification, crystallization, preliminary X-ray diffraction and molecular-replacement studies have been carried out on cormorant (Phalacrocorax carbo) haemoglobin. Crystals were grown by the hanging-drop vapour-diffusion method using PEG 3350, NaCl and glycerol as precipitants. The crystals belonged to themore » trigonal system P3{sub 1}21, with unit-cell parameters a = b = 55.64, c = 153.38 Å, β = 120.00°; a complete data set was collected to a resolution of 3.5 Å. Matthews coefficient analysis indicated that the crystals contained a half-tetramer in the asymmetric unit.« less

  15. Haemoglobin Pierre-Benite--a high affinity variant associated with relative polycythaemia.

    PubMed

    Beard, M E; Potter, H C; Spearing, R L; Brennan, S O

    2001-12-01

    This is the second reported example of Hb Pierre--Benite (beta90 Glu-->Asp). This mutation is associated with increased oxygen affinity and polycythaemia. No instability was found and there was no charge shift detected by cellulose acetate electrophoresis at pH 8.3. The mutation was however, clearly indicated by electrospray ionization mass spectrometry (ESI MS), which showed an abnormal beta chain with a 14 Da decrease in mass. Blood volume studies documented a relative rather than a true polycythaemia and this finding has been reported in at least two other high affinity haemoglobin variants--Hb Heathrow and Hb Rahere. This finding led to delay in diagnosis because high oxygen affinity variants are conventionally considered to cause a true polycythaemia.

  16. Haemoglobin sickle D disease: A presentation with ischaemic stroke.

    PubMed

    Afzal, Hasnain; Umair, Syed Farrukh

    2016-03-01

    Haemoglobin-D, Los Angeles or Haemoglobin D-Punjab is not a rare variant of haemoglobin worldwide especially in Punjab, North western India, and South Asian continent. It can be inherited rarely as homozygous causing no symptoms or heterozygous with Haemoglobin A, commonly not related to clinical symptomatology. However, these variants can co-exist rarely with other haemoglobinopathies such as thalassemia or haemoglobin-S. We describe the case of doubly heterozygous Hb-SD Punjab in a 8 year old girl who presented with ischaemic stroke. Before this case, only one case has been reported but it was with reversible hyperbilirubinaemia in Hb-SD from Rawalpindi, Pakistan. This case images the propensity for occurrence of rare phenotype within our population and underlines the importance of genotyping to avoid erroneous management and poor counseling hence preventing life altering complications which our case developed.

  17. Chemicl-looping combustion of coal with metal oxide oxygen carriers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siriwardane, R.; Tian, H.; Richards, G.

    2009-01-01

    The combustion and reoxidation properties of direct coal chemical-looping combustion (CLC) over CuO, Fe2O3, Co3O4, NiO, and Mn2O3 were investigated using thermogravimetric analysis (TGA) and bench-scale fixed-bed flow reactor studies. When coal is heated in either nitrogen or carbon dioxide (CO2), 50% of weight loss was observed because of partial pyrolysis, consistent with the proximate analysis. Among various metal oxides evaluated, CuO showed the best reaction properties: CuO can initiate the reduction reaction as low as 500 °C and complete the full combustion at 700 °C. In addition, the reduced copper can be fully reoxidized by air at 700 °C.more » The combustion products formed during the CLC reaction of the coal/metal oxide mixture are CO2 and water, while no carbon monoxide was observed. Multicycle TGA tests and bench-scale fixed-bed flow reactor tests strongly supported the feasibility of CLC of coal by using CuO as an oxygen carrier. Scanning electron microscopy (SEM) images of solid reaction products indicated some changes in the surface morphology of a CuO-coal sample after reduction/oxidation reactions at 800 °C. However, significant surface sintering was not observed. The interactions of fly ash with metal oxides were investigated by X-ray diffraction and thermodynamic analysis. Overall, the results indicated that it is feasible to develop CLC with coal by metal oxides as oxygen carriers.« less

  18. Analytical interference of HBOC-201 (Hemopure, a synthetic hemoglobin-based oxygen carrier) on four common clinical chemistry platforms.

    PubMed

    Korte, Erik A; Pozzi, Nicole; Wardrip, Nina; Ayyoubi, M Tayyeb; Jortani, Saeed A

    2018-07-01

    There are 13 million blood transfusions each year in the US. Limitations in the donor pool, storage capabilities, mass casualties, access in remote locations and reactivity of donors all limit the availability of transfusable blood products to patients. HBOC-201 (Hemopure®) is a second-generation glutaraldehyde-polymer of bovine hemoglobin, which can serve as an "oxygen bridge" to maintain oxygen carrying capacity while transfusion products are unavailable. Hemopure presents the advantages of extended shelf life, ambient storage, and limited reactive potential, but its extracellular location can also cause significant interference in modern laboratory analyzers similar to severe hemolysis. Observed error in 26 commonly measured analytes was determined on 4 different analytical platforms in plasma from a patient therapeutically transfused Hemopure as well as donor blood spiked with Hemopure at a level equivalent to the therapeutic loading dose (10% v/v). Significant negative error ratios >50% of the total allowable error (>0.5tAE) were reported in 23/104 assays (22.1%), positive bias of >0.5tAE in 26/104 assays (25.0%), and acceptable bias between -0.5tAE and 0.5tAE error ratio was reported in 44/104 (42.3%). Analysis failed in the presence of Hemopure in 11/104 (10.6%). Observed error is further subdivided by platform, wavelength, dilution and reaction method. Administration of Hemopure (or other hemoglobin-based oxygen carriers) presents a challenge to laboratorians tasked with analyzing patient specimens. We provide laboratorians with a reference to evaluate patient samples, select optimal analytical platforms for specific analytes, and predict possible bias beyond the 4 analytical platforms included in this study. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Intravenous iron in clinical concentrations does not impair haemoglobin measurement.

    PubMed

    O'Loughlin, Edmond; Garnett, Peter Bj; Falkner, Nathalie M; Williams, Robin

    2016-03-01

    Intravenous iron is commonly administered to anaemic patients to treat iron deficiency, but due to its ferric colouration, it may interfere with the spectrophotometric assessment of haemoglobin concentrations. This paper investigates the potential interference of three clinically used intravenous iron preparations on the measurement of haemoglobin. Haemoglobin concentration was measured for neat and Hartmann's solution-diluted iron polymaltose, carboxymaltose and sucrose solutions using bedside (Radiometer HemoCue®), point-of-care (Radiometer ABL800 Flex) and laboratory (Abbott CellDyne Sapphire™) devices. Haemoglobin concentration was then assessed with the same devices utilizing anaemic whole blood with the iron solutions added. Neat iron preparations registered clinically significant haemoglobin concentrations on bedside and laboratory measurements. When intravenous iron preparations were diluted to clinical concentrations, their effect on haemoglobin measurements, either in isolation or mixed with anaemic blood, was negligible. Although neat preparations of intravenous iron do interfere with spectrophotometric analysis of haemoglobin, concentrations likely to be seen post iron infusion do not significantly interfere with haemoglobin measurement. © The Author(s) 2015.

  20. Study of a newly developed high-performance liquid chromatography analyser for glycosylated haemoglobin measurements in blood containing haemoglobin variants in the Japanese population.

    PubMed

    Miyashita, Tetsuo; Sugiyama, Takahiro; Yamadate, Shuukoh; Nagashima, Masaaki; Satomura, Atsushi; Nakayama, Tomohiro

    2014-09-01

    This study examined the new high-performance liquid chromatography analyser HLC-723GX (GX) and investigated its ability to both measure glycosylated haemoglobin (HbA1c) values and determine whether haemoglobin variants could cause interference with these measurements in the Japanese population. For the basic GX examination, the within- and between-run precision, linearity of measurements, correlation of HbA1c values with current systems and the interference of chemically modified haemoglobin were determined. GX interference caused by the haemoglobin variant was examined by analysing 39 clinical laboratory samples that contained haemoglobin variants. Good within- and between-run precision were found, with the coefficients of variation at ≤1.0%. A wide range of HbA1c measurement values were confirmed, with the HbA1c values strongly correlated with the results of the currently used HLC-723G8 system. Chemically modified haemoglobins were prepared by adding glucose, sodium cyanate, acetaldehyde or acetylsalicylic acid to normal blood samples. None of these samples had any influence on the HbA1c values determined by GX. GX analysis showed haemoglobin variants that eluted after HbA0 and were similar to HbD, or HbS had HbA1c values that were close to those measured by boronate affinity chromatography and immunoassay. GX found lower HbA1c values in blood that contained HbE or haemoglobin variants, which elute before or at nearly the same time as HbA0. GX is useful for the analysis of HbA1c samples that contain HbD, HbS, HbC and haemoglobin variants, even though the elution times are similar. However, a countermeasure is needed in order to avoid overlooking other haemoglobin variants in Japan. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  1. Purification, crystallization and preliminary X-ray diffraction studies of parakeet (Psittacula krameri) haemoglobin.

    PubMed

    Jaimohan, S M; Naresh, M D; Arumugam, V; Mandal, A B

    2009-10-01

    Birds often show efficient oxygen management in order to meet the special demands of their metabolism. However, the structural studies of avian haemoglobins (Hbs) are inadequate for complete understanding of the mechanism involved. Towards this end, purification, crystallization and preliminary X-ray diffraction studies have been carried out for parakeet Hb. Parakeet Hb was crystallized as the met form in low-salt buffered conditions after extracting haemoglobin from crude blood by microcentrifugation and purifying the sample by column chromatography. Good-quality crystals were grown from 10% PEG 3350 and a crystal diffracted to about 2.8 A resolution. Preliminary diffraction data showed that the Hb crystal belonged to the monoclinic system (space group C2), with unit-cell parameters a = 110.68, b = 64.27, c = 56.40 A, beta = 109.35 degrees . Matthews volume analysis indicated that the crystals contained a half-tetramer in the asymmetric unit.

  2. Non-symbiotic haemoglobins-What's happening beyond nitric oxide scavenging?

    PubMed

    Hill, Robert D

    2012-01-01

    Non-symbiotic haemoglobins have been an active research topic for over 30 years, during which time a considerable portfolio of knowledge has accumulated relative to their chemical and molecular properties, and their presence and mode of induction in plants. While progress has been made towards understanding their physiological role, there remain a number of unanswered questions with respect to their biological function. This review attempts to update recent progress in this area and to introduce a hypothesis as to how non-symbiotic haemoglobins might participate in regulating hormone signal transduction. Advances have been made towards understanding the structural nuances that explain some of the differences in ligand association characteristics of class 1 and class 2 non-symbiotic haemoglobins. Non-symbiotic haemoglobins have been found to function in seed development and germination, flowering, root development and differentiation, abiotic stress responses, pathogen invasion and symbiotic bacterial associations. Microarray analyses under various stress conditions yield uneven results relative to non-symbiotic haemoglobin expression. Increasing evidence of the role of nitric oxide (NO) in hormone responses and the known involvement of non-symbiotic haemoglobins in scavenging NO provide opportunities for fruitful research, particularly at the cellular level. Circumstantial evidence suggests that non-symbiotic haemoglobins may have a critical function in the signal transduction pathways of auxin, ethylene, jasmonic acid, salicylic acid, cytokinin and abscisic acid. There is a strong need for research on haemoglobin gene expression at the cellular level relative to hormone signal transduction.

  3. Effect of Capacitive and Resistive electric transfer on haemoglobin saturation and tissue temperature.

    PubMed

    Tashiro, Yuto; Hasegawa, Satoshi; Yokota, Yuki; Nishiguchi, Shu; Fukutani, Naoto; Shirooka, Hidehiko; Tasaka, Seishiro; Matsushita, Tomofumi; Matsubara, Keisuke; Nakayama, Yasuaki; Sonoda, Takuya; Tsuboyama, Tadao; Aoyama, Tomoki

    2017-09-01

    This study aims to evaluate the effects of Capacitive and Resistive electric transfer (CRet) and hotpack (HP) on haemoglobin saturation and tissue temperature. The participants were 13 healthy males (mean age 24.5 ± 3.0). They underwent three interventions on different days: (1) CRet (CRet group), (2) HP (HP group) and (3) CRet without power (sham group). The intervention and measurement were applied at the lower paraspinal muscle. Indiba ® active ProRecovery HCR902 was used in the CRet group, and the moist heat method was used in the HP group. Oxygenated, deoxygenated and total haemoglobin (oxy-Hb, deoxy-Hb, total-Hb) counts were measured before and after the 15-min interventions, together with the temperature at the skin surface, and at depths of 10 mm and 20 mm (ST, 10mmDT and 20mmDT, respectively). The haemoglobin saturation and tissue temperature were measured until 30 min after the intervention and were collected at 5-min intervals. Statistical analysis was performed for each index by using the Mann-Whitney U test for comparisons between all groups at each time point. Total-Hb and oxy-Hb were significantly higher in the CRet group than in the HP group continuously for 30 min after the intervention. The 10mmDT and 20mmDT were significantly higher in the CRet group than in the HP group from 10- to 30 min after intervention. The effect on haemoglobin saturation was higher in the CRet group than in the HP group. In addition, the CRet intervention warmed deep tissue more effectively than HP intervention.

  4. Unique phase identification of trimetallic copper iron manganese oxygen carrier using simultaneous differential scanning calorimetry/thermogravimetric analysis during chemical looping combustion reactions with methane

    DOE PAGES

    Benincosa, William; Siriwardane, Ranjani; Tian, Hanjing; ...

    2017-07-05

    Chemical looping combustion (CLC) is a promising combustion technology that generates heat and sequestration-ready carbon dioxide that is undiluted by nitrogen from the combustion of carbonaceous fuels with an oxygen carrier, or metal oxide. This process is highly dependent on the reactivity and stability of the oxygen carrier. The development of oxygen carriers remains one of the major barriers for commercialization of CLC. Synthetic oxygen carriers, consisting of multiple metal components, have demonstrated enhanced performance and improved CLC operation compared to single metal oxides. However, identification of the complex mixed metal oxide phases that form after calcination or during CLCmore » reactions has been challenging. Without an understanding of the dominant metal oxide phase, it is difficult to determine reaction parameters and the oxygen carrier reduction pathway, which are necessary for CLC reactor design. This is particularly challenging for complex multi-component oxygen carriers such as copper iron manganese oxide (CuFeMnO 4). This study aims to differentiate the unique phase formation of a highly reactive, complex trimetallic oxygen carrier, CuFeMnO 4, from its single and bimetallic counterparts using thermochemical and reaction data obtained from simultaneous differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) during temperature programmed reductions (TPR) with methane. DSC/TGA experiments during TPR with methane provides heat flow data and corresponding reaction rate data that can be used to determine reaction routes and mechanisms during methane reduction. Furthermore, non-isothermal TPR data provides the advantage of distinguishing reactions that may not be observable in isothermal analysis. The detailed thermochemical and reaction data, obtained during TPR with methane, distinguished a unique reduction pathway for CuFeMnO 4 that differed from its single and bimetallic counterparts. This is remarkable since X

  5. Unique phase identification of trimetallic copper iron manganese oxygen carrier using simultaneous differential scanning calorimetry/thermogravimetric analysis during chemical looping combustion reactions with methane

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benincosa, William; Siriwardane, Ranjani; Tian, Hanjing

    Chemical looping combustion (CLC) is a promising combustion technology that generates heat and sequestration-ready carbon dioxide that is undiluted by nitrogen from the combustion of carbonaceous fuels with an oxygen carrier, or metal oxide. This process is highly dependent on the reactivity and stability of the oxygen carrier. The development of oxygen carriers remains one of the major barriers for commercialization of CLC. Synthetic oxygen carriers, consisting of multiple metal components, have demonstrated enhanced performance and improved CLC operation compared to single metal oxides. However, identification of the complex mixed metal oxide phases that form after calcination or during CLCmore » reactions has been challenging. Without an understanding of the dominant metal oxide phase, it is difficult to determine reaction parameters and the oxygen carrier reduction pathway, which are necessary for CLC reactor design. This is particularly challenging for complex multi-component oxygen carriers such as copper iron manganese oxide (CuFeMnO 4). This study aims to differentiate the unique phase formation of a highly reactive, complex trimetallic oxygen carrier, CuFeMnO 4, from its single and bimetallic counterparts using thermochemical and reaction data obtained from simultaneous differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) during temperature programmed reductions (TPR) with methane. DSC/TGA experiments during TPR with methane provides heat flow data and corresponding reaction rate data that can be used to determine reaction routes and mechanisms during methane reduction. Furthermore, non-isothermal TPR data provides the advantage of distinguishing reactions that may not be observable in isothermal analysis. The detailed thermochemical and reaction data, obtained during TPR with methane, distinguished a unique reduction pathway for CuFeMnO 4 that differed from its single and bimetallic counterparts. This is remarkable since X

  6. Maternal haemoglobin levels and cardio-metabolic risk factors in childhood: the Generation R study.

    PubMed

    Welten, M; Gaillard, R; Hofman, A; de Jonge, L L; Jaddoe, V W V

    2015-05-01

    To assess whether variations in maternal haemoglobin levels during pregnancy are associated with cardio-metabolic risk factors in school age children. Population-based prospective cohort study. Rotterdam, The Netherlands, 2002-2012. Mothers and children (n = 5002) participating in the Generation R Study. We obtained maternal haemoglobin levels during early pregnancy (median gestational age 14.6 weeks [95% range 10.3, 25.3]) from venous blood samples. Maternal anaemia and elevated haemoglobin levels were based on World Health Organization criteria. We measured childhood cardio-metabolic risk factors at age 6 years. Cardio-metabolic risk factors included body mass index, total fat mass percentage, android/gynoid fat mass ratio, systolic and diastolic blood pressure, left ventricular mass, and blood levels of cholesterol, insulin and C-peptide. Maternal haemoglobin levels were not associated with childhood body mass index, total fat mass percentage, android/gynoid fat mass ratio, systolic blood pressure, cholesterol or insulin levels. Compared with children with normal maternal haemoglobin levels, children from anaemic mothers had slightly higher diastolic blood pressures (difference 0.70 mmHg, 95% CI 0.12, 1.29) and lower C-peptide levels (difference factor 0.93, 95% CI 0.88, 0.98), and children of mothers with elevated haemoglobin levels had lower left ventricular masses (difference -1.08 g, 95% CI -1.88, -0.29). These associations attenuated after adjustment for multiple testing and were not consistent within linear models. These results do not strongly support the hypothesis that variations in maternal haemoglobin levels during pregnancy influence cardio-metabolic risk factors in childhood. © 2014 Royal College of Obstetricians and Gynaecologists.

  7. Glycosylated haemoglobin: measurement and clinical use.

    PubMed

    Peacock, I

    1984-08-01

    The discovery, biochemistry, laboratory determination, and clinical application of glycosylated haemoglobins are reviewed. Sources of error are discussed in detail. No single assay method is suitable for all purposes, and in the foreseeable future generally acceptable standards and reference ranges are unlikely to be agreed. Each laboratory must establish its own. Nevertheless, the development of glycosylated haemoglobin assays is an important advance. They offer the best available means of assessing diabetic control.

  8. Comparison of haemoglobin estimates using direct & indirect cyanmethaemoglobin methods.

    PubMed

    Bansal, Priyanka Gupta; Toteja, Gurudayal Singh; Bhatia, Neena; Gupta, Sanjeev; Kaur, Manpreet; Adhikari, Tulsi; Garg, Ashok Kumar

    2016-10-01

    Estimation of haemoglobin is the most widely used method to assess anaemia. Although direct cyanmethaemoglobin method is the recommended method for estimation of haemoglobin, but it may not be feasible under field conditions. Hence, the present study was undertaken to compare indirect cyanmethaemoglobin method against the conventional direct method for haemoglobin estimation. Haemoglobin levels were estimated for 888 adolescent girls aged 11-18 yr residing in an urban slum in Delhi by both direct and indirect cyanmethaemoglobin methods, and the results were compared. The mean haemoglobin levels for 888 whole blood samples estimated by direct and indirect cyanmethaemoglobin method were 116.1 ± 12.7 and 110.5 ± 12.5 g/l, respectively, with a mean difference of 5.67 g/l (95% confidence interval: 5.45 to 5.90, P<0.001); which is equivalent to 0.567 g%. The prevalence of anaemia was reported as 59.6 and 78.2 per cent by direct and indirect methods, respectively. Sensitivity and specificity of indirect cyanmethaemoglobin method were 99.2 and 56.4 per cent, respectively. Using regression analysis, prediction equation was developed for indirect haemoglobin values. The present findings revealed that indirect cyanmethaemoglobin method overestimated the prevalence of anaemia as compared to the direct method. However, if a correction factor is applied, indirect method could be successfully used for estimating true haemoglobin level. More studies should be undertaken to establish agreement and correction factor between direct and indirect cyanmethaemoglobin methods.

  9. HEMOXCell, a New Oxygen Carrier Usable as an Additive for Mesenchymal Stem Cell Culture in Platelet Lysate-Supplemented Media.

    PubMed

    Le Pape, Fiona; Cosnuau-Kemmat, Lucie; Richard, Gaëlle; Dubrana, Frédéric; Férec, Claude; Zal, Franck; Leize, Elisabeth; Delépine, Pascal

    2017-04-01

    Human mesenchymal stem cells (MSCs) are promising candidates for therapeutic applications such as tissue engineering. However, one of the main challenges is to improve oxygen supply to hypoxic areas to reduce oxygen gradient formation while preserving MSC differentiation potential and viability. For this purpose, a marine hemoglobin, HEMOXCell, was evaluated as an oxygen carrier for culturing human bone marrow MSCs in vitro for future three-dimensional culture applications. Impact of HEMOXCell on cell growth and viability was assessed in human platelet lysate (hPL)-supplemented media. Maintenance of MSC features, such as multipotency and expression of MSC specific markers, was further investigated by biochemical assays and flow cytometry analysis. Our experimental results highlight its oxygenator potential and indicate that an optimal concentration of 0.025 g/L HEMOXCell induces a 25%-increase of the cell growth rate, preserves MSC phenotype, and maintains MSC differentiation properties; a two-fold higher concentration induces cell detachment without altering cell viability. Our data suggest the potential interest of HEMOXCell as a natural oxygen carrier for tissue engineering applications to oxygenate hypoxic areas and to maintain cell viability, functions and "stemness." These features will be further tested within three-dimensional scaffolds. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  10. Different functional modulation by heterotropic ligands (2,3-diphosphoglycerate and chlorides) of the two haemoglobins from fallow-deer (Dama dama).

    PubMed

    Angeletti, M; Pucciarelli, S; Priori, A M; Canofeni, S; Barra, D; Fioretti, E; Coletta, M

    2001-02-01

    Two haemoglobin components have been identified and purified from fallow-deer (Dama dama) erythrocytes. They are present in similar amounts and the two tetrameric molecules share the same alpha chain, while two different beta chains are detected in the two components. The beta chains differ by 14 residues, even though they both have 145 amino-acid residues, which account for a molecular mass of 16,023 and 16,064 Da, respectively, while alpha chain has 141 residues, yielding a molecular mass of 15,142 Da. Compared with human Hb, the N-terminal region of both beta chains shows deletion of Val beta 1 and the replacement of His beta 2 by a methionyl residue, a modification which is common to most ruminant haemoglobins. Although both isolated components show a low intrinsic affinity for oxygen, meaningful differences between the two haemoglobins have been found with respect to the effect of heterotropic effectors, such as 2,3-diphosphoglycerate and chloride ions. In view of the high sequence homology between the two components, the different effect of heterotropic ligands has been tentatively correlated to possible localized structural variations between beta chains of the two haemoglobin components.

  11. Arterial oxygen content is precisely maintained by graded erythrocytotic responses in settings of high/normal serum iron levels, and predicts exercise capacity: an observational study of hypoxaemic patients with pulmonary arteriovenous malformations.

    PubMed

    Santhirapala, Vatshalan; Williams, Louisa C; Tighe, Hannah C; Jackson, James E; Shovlin, Claire L

    2014-01-01

    Oxygen, haemoglobin and cardiac output are integrated components of oxygen transport: each gram of haemoglobin transports 1.34 mls of oxygen in the blood. Low arterial partial pressure of oxygen (PaO2), and haemoglobin saturation (SaO2), are the indices used in clinical assessments, and usually result from low inspired oxygen concentrations, or alveolar/airways disease. Our objective was to examine low blood oxygen/haemoglobin relationships in chronically compensated states without concurrent hypoxic pulmonary vasoreactivity. 165 consecutive unselected patients with pulmonary arteriovenous malformations were studied, in 98 cases, pre/post embolisation treatment. 159 (96%) had hereditary haemorrhagic telangiectasia. Arterial oxygen content was calculated by SaO2 x haemoglobin x 1.34/100. There was wide variation in SaO2 on air (78.5-99, median 95)% but due to secondary erythrocytosis and resultant polycythaemia, SaO2 explained only 0.1% of the variance in arterial oxygen content per unit blood volume. Secondary erythrocytosis was achievable with low iron stores, but only if serum iron was high-normal: Low serum iron levels were associated with reduced haemoglobin per erythrocyte, and overall arterial oxygen content was lower in iron deficient patients (median 16.0 [IQR 14.9, 17.4]mls/dL compared to 18.8 [IQR 17.4, 20.1]mls/dL, p<0.0001). Exercise tolerance appeared unrelated to SaO2 but was significantly worse in patients with lower oxygen content (p<0.0001). A pre-defined athletic group had higher Hb:SaO2 and serum iron:ferritin ratios than non-athletes with normal exercise capacity. PAVM embolisation increased SaO2, but arterial oxygen content was precisely restored by a subsequent fall in haemoglobin: 86 (87.8%) patients reported no change in exercise tolerance at post-embolisation follow-up. Haemoglobin and oxygen measurements in isolation do not indicate the more physiologically relevant oxygen content per unit blood volume. This can be maintained for SaO2

  12. Arterial Oxygen Content Is Precisely Maintained by Graded Erythrocytotic Responses in Settings of High/Normal Serum Iron Levels, and Predicts Exercise Capacity: An Observational Study of Hypoxaemic Patients with Pulmonary Arteriovenous Malformations

    PubMed Central

    Santhirapala, Vatshalan; Williams, Louisa C.; Tighe, Hannah C.; Jackson, James E.; Shovlin, Claire L.

    2014-01-01

    Background Oxygen, haemoglobin and cardiac output are integrated components of oxygen transport: each gram of haemoglobin transports 1.34 mls of oxygen in the blood. Low arterial partial pressure of oxygen (PaO2), and haemoglobin saturation (SaO2), are the indices used in clinical assessments, and usually result from low inspired oxygen concentrations, or alveolar/airways disease. Our objective was to examine low blood oxygen/haemoglobin relationships in chronically compensated states without concurrent hypoxic pulmonary vasoreactivity. Methodology 165 consecutive unselected patients with pulmonary arteriovenous malformations were studied, in 98 cases, pre/post embolisation treatment. 159 (96%) had hereditary haemorrhagic telangiectasia. Arterial oxygen content was calculated by SaO2 x haemoglobin x 1.34/100. Principal Findings There was wide variation in SaO2 on air (78.5–99, median 95)% but due to secondary erythrocytosis and resultant polycythaemia, SaO2 explained only 0.1% of the variance in arterial oxygen content per unit blood volume. Secondary erythrocytosis was achievable with low iron stores, but only if serum iron was high-normal: Low serum iron levels were associated with reduced haemoglobin per erythrocyte, and overall arterial oxygen content was lower in iron deficient patients (median 16.0 [IQR 14.9, 17.4]mls/dL compared to 18.8 [IQR 17.4, 20.1]mls/dL, p<0.0001). Exercise tolerance appeared unrelated to SaO2 but was significantly worse in patients with lower oxygen content (p<0.0001). A pre-defined athletic group had higher Hb:SaO2 and serum iron:ferritin ratios than non-athletes with normal exercise capacity. PAVM embolisation increased SaO2, but arterial oxygen content was precisely restored by a subsequent fall in haemoglobin: 86 (87.8%) patients reported no change in exercise tolerance at post-embolisation follow-up. Significance Haemoglobin and oxygen measurements in isolation do not indicate the more physiologically relevant oxygen content

  13. Anaemia in the sow: a cohort study to assess factors with an impact on haemoglobin concentration, and the influence of haemoglobin concentration on the reproductive performance.

    PubMed

    Normand, V; Perrin, H; Auvigne, V; Robert, N; Laval, A

    2012-10-06

    The aim of this study was to conduct a descriptive study of haemoglobin concentration found on high-prolificacy sows, to study the relationship between the concentration of haemoglobin and body reserves, and to determine whether anaemia is a risk factor for reproductive performance. A cohort of 308 sows from seven farms was followed from the last third of gestation to the confirmation of the following gestation. Haemoglobin concentration was assessed at four stages of the reproductive cycle: seven and four weeks before farrowing, a few days and three weeks after farrowing. Backfat thickness (BFT) was measured at parturition. The results were analysed using linear mixed-effect models. The mean haemoglobin concentration was 108.4 g/l. The mean modellised haemoglobin concentration of parity 1 sows with a BFT of 16 mm, sampled seven weeks before farrowing, was 118 g/l. Haemoglobin concentration of sows of parity 6 or higher was 8.0 g/l lower than those of parity 1 sows (95% confidence interval -11.0 to -5.1). Haemoglobin concentration is lower in sows with a lower BFT, whatever parity rank. There is no evidence of a relation between haemoglobin concentration and the number of total born, stillborn or number of piglets alive at three weeks and the next breeding performance.

  14. Studies on the interference by haemoglobin in the determination of bilirubin.

    PubMed

    van der Woerd-de Lange, J A; Guder, W G; Schleicher, E; Paetzke, I; Schleithoff, M; Wieland, O H

    1983-07-01

    Haemoglobin interference in the determination of bilirubin was compared in 7 different methods using the Jendrassik-Grof procedure, the Jendrassik-Grof-Nosslin modification, and the more recent procedures using nitrophenyldiazonium, 2,5-dichlorophenyldiazonium, 2,4-dichloraniline, and a direct reading method. To a variable degree, haemoglobin decreased the apparent absorption of the reaction product in all procedures. The extent of this decrease depended on the reagent used, the wavelength, incubation time, bilirubin concentration and the type of blank used. In an attempt to elucidate the mechanism of interference, haemoglobin was found to destroy the bilirubin diazo-compound whereas haemoglobin was ineffective. Likewise, storage of haemolytic samples for several days led to a disappearance of haemoglobin. H2O2, which had no effect in the absence of haemoglobin, potentiated the action of haemoglobin on diazobilirubin coupling. From our observations it can be concluded that haemoglobin disturbs the diazo-bilirubin reaction by a dual mechanism. H2O2, formed from oxyhaemoglobin by autoxidation, destroys the diazo bilirubin colour. In accordance with this explanation, potassium iodide stabilized the diazo compound against the peroxidative effect of oxyhaemoglobin; stabilization was not effective with superoxide dismutase, mannitol or ascorbate.

  15. The calcium phosphate coating of soy lecithin nanoemulsion with performance in stability and as an oxygen carrier

    NASA Astrophysics Data System (ADS)

    Han, Kyu B.

    This work studied the relationship between surfactant, oil, and water, by building ternary phase diagrams, the goal of which was to identify the oil-in-water phase composition. The resulting nano-sized emulsion was coated with dicalcium phosphate by utilizing the ionic affinity between calcium ions and the emulsion surface. Since the desired function of the particle is as an oxygen carrier, the particle stability, oxygen capacity, and oxygen release rate were investigated. The first step in the process was to construct ternary phase diagrams with 1,2-dioleoyl-sn-glycero-3-phosphate (DOPA) and soy derived lecithin. The results showed that the lecithin surfactant formed an oil-in-water phase region that was 36 times greater than that of DOPA. With the desired phase composition set, the lecithin emulsion was extruded, resulting in a well-dispersed nanosized particle. A pH titration study of the emulsion found an optimized calcium phosphate coating condition at pH 8.8, at which, the calcium ion had a greater affinity for the emulsion surface than phosphate. A Hill plot was used to show calcium cooperativeness on the emulsion surface which suggested one calcium ion binds to one lecithin molecule. The lecithin emulsion particles were then coated with calcium phosphate using a layering technique that allowed for careful control of the coating thickness. The overall particle hydrodynamic radius was consistent with the growth of the calcium phosphate coating, from 8 nm to 28 nm. This observation was further supported with cryo-TEM measurements. The stability of the coated emulsion was tested in conditions that simulate practical thermal, physical, and time-dependent conditions. Throughout the tests, the coated emulsion exhibited a constant mono-dispersed particle size, while the uncoated emulsion size fluctuated greatly and exhibited increased polydispersion. The fast mixing method with the stopped-flow apparatus was employed to test the product as an oxygen carrier, and it

  16. Foetal haemoglobin concentration at postmenstrual age is unaffected by gestational age at birth.

    PubMed

    Watanabe, Yuki; Osawa, Kayo; Sato, Itsuko; Iwatani, Sota; Kono, Ruri; Hayakawa, Ikuyo; Hayashi, Nobuhide; Iijima, Kazumoto; Saegusa, Jun; Morioka, Ichiro

    2018-05-01

    Background Our aim was to determine whether the postnatal age or postmenstrual age is a more appropriate criterion for evaluating foetal haemoglobin concentrations. Methods Blood samples ( n = 1095) were obtained from 394 infants and were divided into two groups based on gestational age at birth: <37 weeks ( n = 491) and ≥37 weeks ( n = 604). (1) Foetal haemoglobin concentrations divided by one month at age after birth were compared between the groups. (2) Foetal haemoglobin concentrations divided into ≤9 months from last menstruation and one month thereafter were compared between the groups. Results In samples from infants ≥37 weeks' gestational age at birth, the median foetal haemoglobin concentrations were 69.5%, 21.4% and 3.6% at 0-1 month, 2-3 months and ≥5 months after birth, respectively. The median foetal haemoglobin concentrations in infants <37 weeks' gestational age at birth were 75.5%, 62.7% and 5.1% at 0-1 month, 2-3 months and ≥5 months after birth, respectively. The median foetal haemoglobin concentrations in infants <37 weeks' gestational age at birth were significantly higher than that in infants ≥37 weeks' gestational age at birth at all postnatal age points. (2) There was no significant difference between the groups at all age points after nine months of postmenstrual age: 72.5 and 75.3% at 9-10 months, 25.1 and 26.6% at 11-12 months and 5.5 and 4.6% at >13 months after last menstruation in infants ≥37 and <37 weeks' gestational age at birth, respectively. Conclusions Evaluation of foetal haemoglobin concentrations at postmenstrual age is unaffected by gestational age at birth.

  17. Haemoglobin saturation during incremental arm and leg exercise.

    PubMed Central

    Powers, S. K.; Dodd, S.; Woodyard, J.; Beadle, R. E.; Church, G.

    1984-01-01

    There are few reports concerning the alterations in the percent of haemoglobin saturated with oxygen (%SO2) during non-steady state incremental exercise. Further, no data exist to describe the %SO2 changes during arm exercise. Therefore, the purpose of this study was made to assess the dynamic changes in %SO2 during incremental arm and leg work. Nine trained subjects (7 males and 2 females) performed incremental arm and leg exercise to exhaustion on an arm crank ergometer and a cycle ergometer, respectively. Ventilation and gas exchange measurements were obtained minute by minute via open circuit spirometry and changes in %SO2 were recorded via an ear oximeter. No significant difference (p greater than 0.05) existed between arm and leg work in end-tidal oxygen (PETO2), end-tidal carbon dioxide (PETCO2), or %SO2 when compared as a function of percent VO2 max. These results provide evidence that arterial O2 desaturation occurs in a similar fashion in both incremental arm and leg work with the greatest changes in %SO2 occurring at work rates greater than 70% VO2 max. PMID:6435715

  18. Haemoglobin variants may cause significant differences in haemoglobin A1c as measured by high-performance liquid chromatography and enzymatic methods in diabetic patients: a cross-sectional study.

    PubMed

    Otabe, Shuichi; Nakayama, Hitomi; Ohki, Tsuyoshi; Soejima, Eri; Tajiri, Yuji; Yamada, Kentaro

    2017-07-01

    Background We aimed to determine whether the discrepancy between haemoglobin A1c values determined by high-performance liquid chromatography and enzymatic haemoglobin A1c measurements in diabetic patients was clinically relevant. Methods We randomly recruited 1421 outpatients undergoing diabetic treatment and follow-up who underwent at least three haemoglobin A1c measurements between April 2014 and March 2015 at our clinic. In 6369 samples, haemoglobin A1c was simultaneously measured by HA-8160 and MetaboLead (enzymatic assay), and the values were compared. Results haemoglobin A1c measurements by high-performance liquid chromatography and enzymatic assay were strongly correlated (correlation coefficient: 0.9828, linear approximation curve y = 0.9986x - 0.2507). Mean haemoglobin A1c (6.8 ± 1.0%) measured by high-performance liquid chromatography was significantly higher than that measured by enzymatic assay (6.5 ± 1.0%, P < 0.0001). During the sample processing, four (0.3%) subjects presented consistently lower haemoglobin A1c values (<0.7%) by high-performance liquid chromatography than those from enzymatic assay. Of these, three had Hb Toranomon [β112 (G14) Cys→Trp]. The fourth had Hb Ube-2 [α68 (E17) Asn→Asp]. One other subject presented consistently higher haemoglobin A1c values (>1%) by high-performance liquid chromatography than those from enzymatic assay and was diagnosed with a -77 (T > C) mutation in the δ-globin gene. These unrelated asymptomatic subjects had normal erythrocyte profiles, without anaemia. Conclusions We showed that haemoglobin A1c values measured by high-performance liquid chromatography were significantly higher than those measured by enzymatic assay in diabetic subjects. However, when an oversized deviation (>0.7%) between glycaemic control status and haemoglobin A1c is apparent, clinicians should check the methods used to measure haemoglobin A1c and consider the possible presence of a haemoglobin variant.

  19. Labile glycated haemoglobin and carbamylated haemoglobin are still critical points for HbA1c measurement.

    PubMed

    Desmons, Aurore; Jaisson, Stéphane; Leroy, Nathalie; Gillery, Philippe; Guillard, Emmanuelle

    2017-06-15

    Haemoglobin A 1c (HbA 1c ) is a key analyte for the monitoring of glycemic balance in diabetic patients and is used for diabetes diagnosis in many countries. The potential interference of carbamylated haemoglobin (cHb) and labile glycated haemoglobin (LA 1c ) on HbA 1c assays must remain a matter of vigilance. Such a situation has occurred in our laboratory with a kit replacement on the Bio-Rad Variant™ II testing system, a cation-exchange high performance liquid chromatography (HPLC) system. With this method, LA 1c and cHb coeluted in a same peak which may have different consequences on HbA 1c values. The influence of increasing LA 1c and cHb values on HbA 1c results was studied with in vitro glycation and carbamylation of samples. Samples from patients with high and normal blood urea concentrations were assayed by HPLC and immunological assay. We observed that the degree of interference greatly varied depending on the nature of the interfering Hb fractions found under the so-called "LA 1c peak". Thus, we have decided to apply a decision tree using "LA 1c " thresholds depending on: (i) the retention time, (ii) the shape of the peak, (iii) other analytes, like urea. If the peak recognized as "LA 1c " is mainly formed by LA 1c, we consider that there is no interference until 4%. If the peak is mainly formed by cHb, we consider an interference threshold equal to 2%. This situation reminds that cHb and LA 1c remain critical issues in chromatography-based HbA 1c assays and that adapted criteria must be set up for result interpretation.

  20. Knowledge Insufficient: The Management of Haemoglobin SC Disease

    PubMed Central

    Pecker, Lydia H.; Schaefer, Beverly A.; Luchtman-Jones, Lori

    2016-01-01

    Although haemoglobin SC (HbSC) accounts for 30% of sickle cell disease (SCD) in the United States and United Kingdom, evidence-based guidelines for genotype specific management are lacking. The unique pathology of HbSC disease is complex, characterized by erythrocyte dehydration, intracellular sickling and increased blood viscosity. The evaluation and treatment of patients with HbSC is largely inferred from studies of SCD consisting mostly of haemoglobin SS (HbSS) patients. These studies are underpowered to allow definitive conclusions about HbSC. We review the pathophysiology of HbSC disease, including known and potential differences between HbSS and HbSC, and highlight knowledge gaps in HbSC disease management. Clinical and translational research is needed to develop targeted treatments and to validate management recommendations for efficacy, safety and impact on quality of life for people with HbSC. PMID:27982424

  1. Preferred temperature of juvenile Atlantic cod Gadus morhua with different haemoglobin genotypes at normoxia and moderate hypoxia.

    PubMed

    Petersen, Maria Faldborg; Steffensen, John Fleng

    2003-01-01

    Atlantic cod Gadus morhua has polymorphic haemoglobin, which can be separated into two homozygous types, HbI-1 and HbI-2, and one heterozygous type HbI-1/2. The geographical distribution of Atlantic cod with the different haemoglobin types varies, with the HbI(2) allele occurring at high frequency in northern regions, and the HbI(1) allele dominant in warmer areas. To determine if temperature is a selective parameter in the distribution of the haemoglobin types, the preferred temperature of the homozygous genotypes HbI-1 and HbI-2 was measured. We found that HbI-2 cod preferred a temperature of 8.2+/-1.5 degrees C while HbI-1 cod preferred 15.4+/-1.1 degrees C, and this preference was significant. The effect of hypoxia (35% oxygen saturation) on the preferred temperature was also measured. Previous studies showed that the preferred temperature of fish decreases during hypoxia, and this was the case for HbI-1 cod, which preferred 9.8+/-1.8 degrees C during hypoxia, whereas HbI-2 cod did not show this effect. The results indicate that environmental temperature changes will lead to a distributional change in the different haemoglobin types of Atlantic cod, global warming providing an advantage for HbI-1 cod. However, since HbI-1 cod prefer a low temperature under hypoxic conditions, a combination of increased water temperature and hypoxia could be unfavourable for Atlantic cod stocks.

  2. Generation of reactive oxygen species and charge carriers in plasmonic photocatalytic Au@TiO2 nanostructures with enhanced activity.

    PubMed

    He, Weiwei; Cai, Junhui; Jiang, Xiumei; Yin, Jun-Jie; Meng, Qingbo

    2018-06-13

    The combination of semiconductor and plasmonic nanostructures, endowed with high efficiency light harvesting and surface plasmon confinement, has been a promising way for efficient utilization of solar energy. Although the surface plasmon resonance (SPR) assisted photocatalysis has been extensively studied, the photochemical mechanism, e.g. the effect of SPR on the generation of reactive oxygen species and charge carriers, is not well understood. In this study, we take Au@TiO2 nanostructures as a plasmonic photocatalyst to address this critical issue. The Au@TiO2 core/shell nanostructures with tunable SPR property were synthesized by the templating method with post annealing thermal treatment. It was found that Au@TiO2 nanostructures exhibit enhanced photocatalytic activity in either sunlight or visible light (λ > 420 nm). Electron spin resonance spectroscopy with spin trapping and spin labeling was used to investigate the enhancing effect of Au@TiO2 on the photo-induced reactive oxygen species and charge carriers. The formation of Au@TiO2 core/shell nanostructures resulted in a dramatic increase in light-induced generation of hydroxyl radicals, singlet oxygen, holes and electrons, as compared with TiO2 alone. This enhancement under visible light (λ > 420 nm) irradiation may be dominated by SPR induced local electrical field enhancement, while the enhancement under sunlight irradiation is dominated by the higher electron transfer from TiO2 to Au. These results unveiled that the superior photocatalytic activity of Au@TiO2 nanostructures correlates with enhanced generation of reactive oxygen species and charge carriers.

  3. Acquisition of haemoglobin-bound iron by strains of the Actinobacillus minor/"porcitonsillarum" complex.

    PubMed

    Arya, Gitanjali; Niven, Donald F

    2011-03-24

    Members of the Actinobacillus minor/"porcitonsillarum" complex are common inhabitants of the swine respiratory tract. Although avirulent or of low virulence for pigs, these organisms, like pathogens, do grow in vivo and must, therefore, be able to acquire iron within the host. Here, we investigated the abilities of six members of the A. minor/"porcitonsillarum" complex to acquire iron from transferrin and various haemoglobins. Using growth assays, all six strains were shown to acquire iron from porcine, bovine and human haemoglobins but not from porcine transferrin. Analyses of whole genome sequences revealed that A. minor strains NM305(T) and 202, unlike the swine-pathogenic actinobacilli, A. pleuropneumoniae and A. suis, lack not only the transferrin-binding protein genes, tbpA and tbpB, but also the haemoglobin-binding protein gene, hgbA. Strains NM305(T) and 202, however, were found to possess other putative haemin/haemoglobin-binding protein genes that were predicted to encode mature proteins of ∼ 72 and ∼ 75 kDa, respectively. An affinity procedure based on haemin-agarose allowed the isolation of ∼ 65 and ∼ 67 kDa iron-repressible outer membrane polypeptides from membranes derived from strains NM305(T) and 202, respectively, and mass spectrometry revealed that these polypeptides were the products of the putative haemin/haemoglobin-binding protein genes. PCR approaches allowed the amplification and sequencing of homologues of both haemin/haemoglobin-binding protein genes from each of the other four strains, strains 33PN and 7ATS of the A. minor/"porcitonsillarum" complex and "A. porcitonsillarum" strains 9953L55 and 0347, suggesting that such proteins are involved in the utilization of haemoglobin-bound iron, presumably as surface receptors, by all six strains investigated. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Critical insight into the interaction of naringenin with human haemoglobin: A combined spectroscopic and computational modeling approaches

    NASA Astrophysics Data System (ADS)

    Maity, Subhajit; Chakraborty, Sandipan; Chakraborti, Abhay Sankar

    2017-02-01

    The present study demonstrates critical insight into the binding of a bioactive flavanone naringenin with normal human haemoglobin (NHb). Both spectrophotometric and spectrofluorimetric studies reveal that naringenin interacts with NHb. The binding affinity constant and number of binding sites appear to be approximately (1.5 ± 0.2) × 104 M-1 and 1, respectively. Static quenching seems to be an important factor in binding process, as evident from steady-state and time-resolved fluorescence spectroscopic studies. Far UV circular dichroism spectroscopy depicts that binding of naringenin to NHb causes no change in the secondary structure of the protein, which is also evident from Fourier transform infrared spectroscopic study. Free energy change (ΔG0) for naringenin-NHb interaction, determined by spectroscopic and isothermal calorimetric method, appears to be -5.67 kcal/mol and -6.90 kcal/mol, respectively, and is close to the docking energy -6.84 kcal/mol. Molecular docking suggests that naringenin binds near the cavity of the tetrameric heme protein, forming hydrogen bonds with surrounding amino acid residues. The binding site is away from the heme moieties, implicating naringenin binding does not affect the oxygen binding capacity of NHb, which makes the protein a suitable carrier of the flavonoid.

  5. Expected outcomes from topical haemoglobin spray in non-healing and worsening venous leg ulcers.

    PubMed

    Arenberger, P; Elg, F; Petyt, J; Cutting, K

    2015-05-01

    To evaluate the effect of topical haemoglobin spray on treatment response and wound-closure rates in patients with chronic venous leg ulcers. A linear regression model was used to forecast healing outcomes over a 12-month period. Simulated data were taken from normal distributions based on post-hoc analysis of a 72-patient study in non-healing and worsening wounds (36 patients receiving standard care and 36 receiving standard care plus topical haemoglobin spray). Using a simulated 25,000 'patients' from each group, the proportion of wound closure over time was projected. Simulation results predicted a 55% wound closure rate at six months in the haemoglobin group, compared with 4% in the standard care group. Over a 12-month simulation period, a 43% overall reduction in wound burden was predicted. With the haemoglobin spray, 85% of wounds were expected to heal in 12 months, compared with 13% in the standard care group. Topical haemoglobin spray promises a more effective treatment for chronic venous leg ulcers than standard care alone in wounds that are non-healing or worsening. Further research is required to validate these predictions and to identify achievable outcomes in other chronic wound types.

  6. Deep vs shallow nature of oxygen vacancies and consequent n -type carrier concentrations in transparent conducting oxides

    NASA Astrophysics Data System (ADS)

    Buckeridge, J.; Catlow, C. R. A.; Farrow, M. R.; Logsdail, A. J.; Scanlon, D. O.; Keal, T. W.; Sherwood, P.; Woodley, S. M.; Sokol, A. A.; Walsh, A.

    2018-05-01

    The source of n -type conductivity in undoped transparent conducting oxides has been a topic of debate for several decades. The point defect of most interest in this respect is the oxygen vacancy, but there are many conflicting reports on the shallow versus deep nature of its related electronic states. Here, using a hybrid quantum mechanical/molecular mechanical embedded cluster approach, we have computed formation and ionization energies of oxygen vacancies in three representative transparent conducting oxides: In2O3 ,SnO2, and ZnO. We find that, in all three systems, oxygen vacancies form well-localized, compact donors. We demonstrate, however, that such compactness does not preclude the possibility of these states being shallow in nature, by considering the energetic balance between the vacancy binding electrons that are in localized orbitals or in effective-mass-like diffuse orbitals. Our results show that, thermodynamically, oxygen vacancies in bulk In2O3 introduce states above the conduction band minimum that contribute significantly to the observed conductivity properties of undoped samples. For ZnO and SnO2, the states are deep, and our calculated ionization energies agree well with thermochemical and optical experiments. Our computed equilibrium defect and carrier concentrations, however, demonstrate that these deep states may nevertheless lead to significant intrinsic n -type conductivity under reducing conditions at elevated temperatures. Our study indicates the importance of oxygen vacancies in relation to intrinsic carrier concentrations not only in In2O3 , but also in SnO2 and ZnO.

  7. Role of lipocalin 2 in intraventricular haemoglobin-induced brain injury

    PubMed Central

    Shishido, Hajime; Toyota, Yasunori; Hua, Ya; Keep, Richard F; Xi, Guohua

    2016-01-01

    Objective Our recent studies have shown that blood components, including haemoglobin and iron, contribute to hydrocephalus development and brain injury after intraventricular haemorrhage (IVH). The current study investigated the role of lipocalin 2 (LCN2), a protein involved in iron handling, in the ventricular dilation and neuroinflammation caused by brain injury in a mouse model of IVH. Design Female wild-type (WT) C57BL/6 mice and LCN2-deficient (LCN2−/−) mice had an intraventricular injection of haemoglobin, and control mice received an equivalent amount of saline. MRI was performed presurgery and postsurgery to measure ventricular volume and the brains were used for either immunohistochemistry or western blot. Results Ventricular dilation was observed in WT mice at 24 h after haemoglobin (25 mg/mL, 20 µL) injection (12.5±2.4 vs 8.6±1.5 mm3 in the control, p<0.01). Western blotting showed that LCN2 was significantly upregulated in the periventricular area (p<0.01). LCN2 was mainly expressed in astrocytes, whereas the LCN2 receptor was detected in astrocytes, microglia/macrophages and neurons. Haemoglobin-induced ventricle dilation and glia activation were less in LCN2−/− mice (p<0.01). Injection of high-dose haemoglobin (50 mg/mL) resulted in lower mortality in LCN2−/− mice (27% vs 86% in WT; p<0.05). Conclusions Intraventricular haemoglobin caused LCN2 upregulation and ventricular dilation. Haemoglobin resulted in lower mortality and less ventricular dilation in LCN2−/− mice. These results suggest that LCN2 has a role in haemoglobin-induced brain injury and may be a therapeutic target for IVH. PMID:28959462

  8. Effect of hemoglobin polymerization on oxygen transport in hemoglobin solutions.

    PubMed

    Budhiraja, Vikas; Hellums, J David

    2002-09-01

    The effect of hemoglobin (Hb) polymerization on facilitated transport of oxygen in a bovine hemoglobin-based oxygen carrier was studied using a diffusion cell. In high oxygen tension gradient experiments (HOTG) at 37 degrees C the diffusion of dissolved oxygen in polymerized Hb samples was similar to that in unpolymerized Hb solutions during oxygen uptake. However, in the oxygen release experiments, the transport by diffusion of dissolved oxygen was augmented by diffusion of oxyhemoglobin over a range of oxygen saturations. The augmentation was up to 30% in the case of polymerized Hb and up to 100% in the case of unpolymerized Hb solution. In experiments performed at constant, low oxygen tension gradients in the range of physiological significance, the augmentation effect was less than that in the HOTG experiments. Oxygen transport in polymerized Hb samples was approximately the same as that in unpolymerized samples over a wide range of oxygen tensions. However, at oxygen tensions lower than 30 mm Hg, there were more significant augmentation effects in unpolymerized bovine Hb samples than in polymerized Hb. The results presented here are the first accurate, quantitative measurements of effective diffusion coefficients for oxygen transport in hemoglobin-based oxygen carriers of the type being evaluated to replace red cells in transfusions. In all cases the oxygen carrier was found to have higher effective oxygen diffusion coefficients than blood.

  9. Effect of melatonin on the blood oxygen transport during hypothermia and rewarming in rats.

    PubMed

    Hlutkin, S; Zinchuk, V

    2008-01-01

    We aimed to study effect of melatonin on the blood oxygen transport during hypothermia and rewarming in rats. Cold exposure was performed on male rats (body weight 220-270 g, n=48) for 120 minutes under the box water temperature of 19 degrees C; rewarming took the next 120 min, with a mean rate of 0.06 degrees C/min. Melatonin was administered intraperitoneally 30 min before the cold exposure (bolus doses of 0.1, 1 or 10 mg/kg, or 1 mg/kg*day for 4 days). Haemoglobin-oxygen affinity was evaluated by p50 (blood pO2 at its 50% O2 saturation) determined by the "mixing" method at 37 degrees C, pH 7.4 and pCO2 40 mm Hg (p50stand) and at actual pH, pCO2 and temperature (p50act). After hypothermia and rewarming, the values of p50stand and p50act were 31.5+/-0.28 and 30.2+/-0.61 mm Hg, respectively. The 0.1 mg/kg of melatonin virtually did not change these values, whereas the larger doses increased them. This effect was maximal after the prolonged (4 days) melatonin administration: p50stand rose by 5.4% (p<0.05) and p50act--by 12.9 (p<0.05) compared with rats without the melatonin treatment. Melatonin affected the mechanisms of O2 transport by decreasing the haemoglobin-oxygen affinity (shifting the oxygen dissociation curve of haemoglobin rightwards) and promoting the tissue oxygenation, thereby enhancing the body's resistance to cold. The melatonin effect mediated by haemoglobin-oxygen affinity change may be used for the correction of metabolic disorders and the improvement of the body's resistance to low environmental temperature.

  10. Knowledge insufficient: the management of haemoglobin SC disease.

    PubMed

    Pecker, Lydia H; Schaefer, Beverly A; Luchtman-Jones, Lori

    2017-02-01

    Although haemoglobin SC (HbSC) accounts for 30% of sickle cell disease (SCD) in the United States and United Kingdom, evidence-based guidelines for genotype specific management are lacking. The unique pathology of HbSC disease is complex, characterized by erythrocyte dehydration, intracellular sickling and increased blood viscosity. The evaluation and treatment of patients with HbSC is largely inferred from studies of SCD consisting mostly of haemoglobin SS (HbSS) patients. These studies are underpowered to allow definitive conclusions about HbSC. We review the pathophysiology of HbSC disease, including known and potential differences between HbSS and HbSC, and highlight knowledge gaps in HbSC disease management. Clinical and translational research is needed to develop targeted treatments and to validate management recommendations for efficacy, safety and impact on quality of life for people with HbSC. © 2016 John Wiley & Sons Ltd.

  11. Liposomes as potential masking agents in sport doping. Part 2: Detection of liposome-entrapped haemoglobin by flow cytofluorimetry.

    PubMed

    Esposito, Simone; Colicchia, Sonia; de la Torre, Xavier; Donati, Francesco; Mazzarino, Monica; Botrè, Francesco

    2017-02-01

    This work presents an analytical procedure for the identification and characterization of liposome-entrapped haemoglobins, based on flow cytofluorimetry. Flow cytofluorimetric detection is carried out following labelling by two distinct fluorescent reagents, an anti-haemoglobin antibody, fluorescein isothiocyanate conjugated, and an anti-poly(ethylene glycol) antibody, streptavidin-phycoerythrin conjugated. This experimental strategy allows the detection of liposome-entrapped haemoglobins in aqueous media, including plasma; the efficacy of the proposed approach has been verified on whole blood samples added with the liposomal formulation (ex-vivo). Additionally, the proposed technique allows the characterization of several key parameters in the study of liposomal haemoglobins, including, for instance (1) the determination of the degree of haemoglobin entrapment by liposomes; (2) the poly(ethylene glycol) insertion efficiency; and (3) the evaluation of liposome-entrapped haemoglobins stability following storage at 4 °C, allowing to follow both the process of haemoglobin loss from liposomes and the liposome degradation. The procedure is proposed for the detection and characterization of liposome-entrapped haemoglobin formulations to control their misuse in sport, but is also suggested for further applications in biological and clinical laboratory investigations. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Prognostic implications of baseline anaemia and changes in haemoglobin concentrations with amphotericin B therapy for cryptococcal meningitis.

    PubMed

    Tugume, L; Morawski, B M; Abassi, M; Bahr, N C; Kiggundu, R; Nabeta, H W; Hullsiek, K H; Taseera, K; Musubire, A K; Schutz, C; Muzoora, C; Williams, D A; Rolfes, M A; Meintjes, G; Rhein, J; Meya, D B; Boulware, D R

    2017-01-01

    Anaemia represents a common toxicity with amphotericin B-based induction therapy in HIV-infected persons with cryptococcal meningitis. We sought to examine the impact of amphotericin-related anaemia on survival. We used data from Ugandan and South African trial participants to characterize the variation of haemoglobin concentrations from diagnosis to 12 weeks post-diagnosis. Anaemia severity was classified based on the haemoglobin concentration at cryptococcal meningitis diagnosis, and nadir haemoglobin values during amphotericin induction. Cox proportional hazard models were used to estimate 2- and 10-week mortality risk. We also estimated 10-week mortality risk among participants with nadir haemoglobin < 8.5 g/dL during amphotericin induction and who survived ≥ 2 weeks post-enrolment. The median haemoglobin concentration at meningitis diagnosis was 11.5 g/dL [interquartile range (IQR) 9.7-13 g/dL; n = 311] with a mean decline of 4.2 g/dL [95% confidence interval (CI) -4.6 to -3.8; P < 0.001; n = 148] from diagnosis to nadir value among participants with baseline haemoglobin ≥ 8.5 g/dL. The median haemoglobin concentration was 8.1 g/dL (IQR 6.5-9.5 g/dL) at 2 weeks, increasing to 9.4 g/dL (IQR 8.2-10.9 g/dL) by 4 weeks and continuing to increase to 12 weeks. Among participants with haemoglobin < 8.5 g/dL at diagnosis, mortality risk was elevated at 2 weeks [hazard ratio (HR) 2.7; 95% CI 1.5-4.9; P < 0.01] and 10 weeks (HR 1.8; 95% CI 1.1-2.2; P = 0.03), relative to those with haemoglobin ≥ 8.5 g/dL. New-onset anaemia occurring with amphotericin therapy did not have a statistically significant association with 10-week mortality (HR 2.0; 95% CI 0.5-9.1; P = 0.4). Amphotericin induced significant haemoglobin declines, which were mostly transient and did not impact 10-week mortality. Individuals with moderate to life-threatening anaemia at baseline had a higher mortality risk at 2 and 10 weeks post-enrolment. © 2016 British HIV Association.

  13. Carboxyhaemoglobin: a possible reference material for haemoglobin assay.

    PubMed Central

    Rideout, J M; Louderback, A

    1982-01-01

    The inter- and intralaboratory quality control of haemoglobin estimation in remote laboratories requires a more rugged control haemolysate than is commercially available. The stabilities of oxyhaemoglobin and carboxyhaemoglobin forms of an ethanediol-containing haemolysate were studied over a three-year period. From the results obtained, carboxyhaemoglobin under nitrogen is proposed as a possible candidate reference material for haemoglobin assay. PMID:7068921

  14. Low versus high haemoglobin concentration threshold for blood transfusion for preventing morbidity and mortality in very low birth weight infants.

    PubMed

    Whyte, Robin; Kirpalani, Haresh

    2011-11-09

    Infants of very low birth weight often receive multiple transfusions of red blood cells, usually in response to predetermined haemoglobin or haematocrit thresholds. In the absence of better indices, haemoglobin levels are imperfect but necessary guides to the need for transfusion. Chronic anaemia in premature infants may, if severe, cause apnoea, poor neurodevelopmental outcomes or poor weight gain.On the other hand, red blood cell transfusion may result in transmission of infections, circulatory or iron overload, or dysfunctional oxygen carriage and delivery. To determine if erythrocyte transfusion administered to maintain low as compared to high haemoglobin thresholds reduces mortality or morbidity in very low birth weight infants enrolled within three days of birth. Two review authors independently searched the Cochrane Central Register of Controlled Trials (The Cochrane Library) , MEDLINE,EMBASE, and conference proceedings through June 2010. We selected randomised controlled trials (RCTs) comparing the effects of early versus late, or restrictive versus liberal erythrocyte transfusion regimes in low birth weight infants applied within three days of birth, with mortality or major morbidity as outcomes.

  15. Red cell 2,3-diphosphoglycerate and oxygen affinity.

    PubMed

    MacDonald, R

    1977-06-01

    The ease with which haemoglobin releases oxygen to the tissues is controlled by erythrocytic 2,3-diphosphoglycerate (2,3-DPG) such that an increase in the concentration of 2,3-DPG decreases oxygen affinity and vice versa. This review article describes the synthesis and breakdown of 2,3-DPG in the Embden-Meyerof pathway in red cells and briefly explains the molecular basis for its effect on oxygen affinity. Interaction of the effects of pH, Pco2, temperature and 2,3-DPG on the oxyhaemoglobin dissociation curve are discussed. The role of 2,3-DPG in the intraerythrocytic adaptation to various types of hypoxaemia is described. The increased oxygen affinity of blood stored in acid-citrate-dextrose (ACD) solution has been shown to be due to the decrease in the concentration of 2,3-DPG which occurs during storage. Methods of maintaining the concentration of 2,3-DPG in stored blood are described. The clinical implication of transfusion of elderly people, anaemic or pregnant patients with ACD stored blood to anaesthetically and surgically acceptable haemoglobin concentrations are discussed. Hypophosphataemia in association with parenteral feeding reduces 2,3-DPG concentration and so increases oxygen affinity. Since post-operative use of intravenous fluids such as dextrose or dextrose/saline also lead to hypophosphataemia, the addition of inorganic phosphorus to routine post-operative intravenous fluid may be advisable. Disorders of acid-base balance effect oxygen affinity not only by the direct effect of pH on the oxyhaemoglobin dissociation curve but by its control of 2,3-DPG metabolism. Management of acid-base disorders and pre-operative aklalinization of patients with sickle cell disease whould take account of this. It is known that anaesthesia alters the position of the oxyhaemoglobin dissociation curve, but it is thought that this is independent of any effects which anaesthetic agents may have on 2,3-DPG concentration. In vitro manipulation of 2,3-DPG concentration

  16. Absorption process for producing oxygen and nitrogen and solution therefor

    DOEpatents

    Roman, Ian C. [Wilmington, DE; Baker, Richard W. [Palo Alto, CA

    1990-09-25

    Process for the separation and purification of oxygen and nitrogen is disclosed which utilizes solutions of oxygen carriers to selectively absorb oxygen from a gaseous stream, leaving nitrogen as a byproduct. In the process, an oxygen carrier capable of reversibly binding molecular oxygen is dissolved in a solvent solution, which absorbs oxygen from an oxygen-containing gaseous feed stream such as atmospheric air and desorbs oxygen to a gaseous product stream. The feed stream is maintained at a sufficiently high oxygen pressure to keep the oxygen carrier in its oxygenated form during absorption, while the product stream is maintained at a sufficiently low oxygen pressure to keep the carrier in its deoxygenated form during desorption. In an alternate mode of operation, the carrier solution is maintained at a sufficiently low temperature and high oxygen pressure to keep the oxygen carrier in its oxygenated form during absorption, and at a sufficiently high temperature to keep the carrier in its deoxygenated form during desorption. Under such conditions, exceptionally high oxygen concentrations on the order of 95% to 99% are obtained, as well as a long carrier lifetime in excess of 3 months, making the process commercially feasible.

  17. Absorption process for producing oxygen and nitrogen and solution therefor

    DOEpatents

    Roman, I.C.; Baker, R.W.

    1990-09-25

    Process for the separation and purification of oxygen and nitrogen is disclosed which utilizes solutions of oxygen carriers to selectively absorb oxygen from a gaseous stream, leaving nitrogen as a byproduct. In the process, an oxygen carrier capable of reversibly binding molecular oxygen is dissolved in a solvent solution, which absorbs oxygen from an oxygen-containing gaseous feed stream such as atmospheric air and desorbs oxygen to a gaseous product stream. The feed stream is maintained at a sufficiently high oxygen pressure to keep the oxygen carrier in its oxygenated form during absorption, while the product stream is maintained at a sufficiently low oxygen pressure to keep the carrier in its deoxygenated form during desorption. In an alternate mode of operation, the carrier solution is maintained at a sufficiently low temperature and high oxygen pressure to keep the oxygen carrier in its oxygenated form during absorption, and at a sufficiently high temperature to keep the carrier in its deoxygenated form during desorption. Under such conditions, exceptionally high oxygen concentrations on the order of 95% to 99% are obtained, as well as a long carrier lifetime in excess of 3 months, making the process commercially feasible. 1 figure

  18. Absorption process for producing oxygen and nitrogen and solution therefor

    DOEpatents

    Roman, Ian C.

    1984-01-01

    Process for the separation and purification of oxygen and nitrogen is disclosed which utilizes solutions of oxygen carriers to selectively absorb oxygen from a gaseous stream, leaving nitrogen as a byproduct. In the process, an oxygen carrier capable of reversibly binding molecular oxygen is dissolved in a solvent solution, which absorbs oxygen from an oxygen-containing gaseous feed stream such as atmospheric air and desorbs oxygen to a gaseous product stream. The feed stream is maintained at a sufficiently high oxygen pressure to keep the oxygen carrier in its oxygenated form during absorption, while the product stream is maintained at a sufficiently low oxygen pressure to keep the carrier in its deoxygenated form during desorption. In an alternate mode of operation, the carrier solution is maintained at a sufficiently low temperature and high oxygen pressure to keep the oxygen carrier in its oxygenated form during absorption, and at a sufficiently high temperature to keep the carrier in its deoxygenated form during desorption. Under such conditions, exceptionally high oxygen concentrations on the order of 95% to 99% are obtained, as well as a long carrier lifetime in excess of 3 months, making the process commercially feasible.

  19. Identification of a rare variant haemoglobin (Hb Sinai-Baltimore) causing spuriously low haemoglobin A(1c) values on ion exchange chromatography.

    PubMed

    Smith, Geoff; Murray, Heather; Brennan, Stephen O

    2013-01-01

    Commonly used methods for assay of haemoglobin A(1c) (HbA(1c)) are susceptible to interference from the presence of haemoglobin variants. In many systems, the common variants can be identified but scientists and pathologists must remain vigilant for more subtle variants that may result in spuriously high or low HbA(1c) values. It is clearly important to recognize these events whether HbA(1c) is being used as a monitoring tool or, as is increasingly the case, for diagnostic purposes. We report a patient with a rare haemoglobin variant (Hb Sinai-Baltimore) that resulted in spuriously low values of HbA(1c) when assayed using ion exchange chromatography, and the steps taken to elucidate the nature of the variant.

  20. Tissue oxygenation and haemodynamics measurement with spatially resolved NIRS

    NASA Astrophysics Data System (ADS)

    Zhang, Y.; Scopesi, F.; Serra, G.; Sun, J. W.; Rolfe, P.

    2010-08-01

    We describe the use of Near Infrared Spectroscopy (NIRS) for the non-invasive investigation of changes in haemodynamics and oxygenation of human peripheral tissues. The goal was to measure spatial variations of tissue NIRS oxygenation variables, namely deoxy-haemoglobin (HHb), oxy-haemoglobin (HbO2), total haemoglobin (HbT), and thereby to evaluate the responses of the peripheral circulation to imposed physiological challenges. We present a skinfat- muscle heterogeneous tissue model with varying fat thickness up to 15mm and a Monte Carlo simulation of photon transport within this model. The mean partial path length and the mean photon visit depth in the muscle layer were derived for different source-detector spacing. We constructed NIRS instrumentation comprising of light-emitting diodes (LED) as light sources at four wavelengths, 735nm, 760nm, 810nm and 850nm and sensitive photodiodes (PD) as the detectors. Source-detector spacing was varied to perform measurements at different depths within forearm tissue. Changes in chromophore concentration in response to venous and arterial occlusion were calculated using the modified Lambert-Beer Law. Studies in fat and thin volunteers indicated greater sensitivity in the thinner subjects for the tissue oxygenation measurement in the muscle layer. These results were consistent with those found using Monte Carlo simulation. Overall, the results of this investigation demonstrate the usefulness of the NIRS instrument for deriving spatial information from biological tissues.

  1. Noninvasive methods for haemoglobin screening in prospective blood donors.

    PubMed

    Belardinelli, A; Benni, M; Tazzari, P L; Pagliaro, P

    2013-08-01

    The haemoglobin level of prospective blood donors is usually performed on blood obtained by from the finger pulp by fingerstick with a lancet and filling a capillary tube with a sample. New noninvasive methods are now available for rapid, noninvasive predonation haemoglobin screening. Prospective blood donors at our blood centre were tested, in two different trials, as follows: by the NBM 200 (OrSense) test (n = 445 donors) and by the Pronto-7 (Masimo) test (n = 463 donors). The haemoglobin values of each trial and the haemoglobin of finger pulp blood obtained by fingerstick with a lancet (HemoCue) were compared with the haemoglobin values obtained from a venous sample on a Cell Counter (Beckman Coulter). Comparison of Beckman Coulter Cell Counter and OrSense and results showed a bias of 0.29 g/dl, the standard deviation of the differences (SDD) of 0.98 and 95% limits of agreement from -1.64 to 2.21, using Bland and Altman statistical methodology. Comparison of Masimo and Beckman Coulter Cell Counter results showed a bias of -0.53 g/dl, SDD of 1.04 and 95% limits of agreement from -2.57 to 1.51. Cumulative analysis of all 908 donors, as tested by the usual fingerstick test showed a bias of 0.83 g/dl, SDD of 0.70 and 95% limits of agreement from -0.54 to 2.20 compared with the Coulter Cell Counter. Compared with the Coulter Counter, the specificity of the methods was 99.5% for fingerstick, 97% for OrSense and 83% for Massimo, and the sensitivity was 99, 98 and 93%, respectively. Analysis of finger pulp blood by either direct sampling by fingerstick and Hemocue, or by noninvasive haemoglobin tests does not replicate the results of cell counter analysis of venous samples. Compared with fingerstick, noninvasive haemoglobin tests eliminate pain and reduce stress, but have a lower level of specificity and sensitivity. © 2013 International Society of Blood Transfusion.

  2. The oxygen-conserving potential of the diving response: A kinetic-based analysis.

    PubMed

    Costalat, Guillaume; Coquart, Jeremy; Castres, Ingrid; Joulia, Fabrice; Sirost, Olivier; Clua, Eric; Lemaître, Frédéric

    2017-04-01

    We investigated the oxygen-conserving potential of the human diving response by comparing trained breath-hold divers (BHDs) to non-divers (NDs) during simulated dynamic breath-holding (BH). Changes in haemodynamics [heart rate (HR), stroke volume (SV), cardiac output (CO)] and peripheral muscle oxygenation [oxyhaemoglobin ([HbO 2 ]), deoxyhaemoglobin ([HHb]), total haemoglobin ([tHb]), tissue saturation index (TSI)] and peripheral oxygen saturation (SpO 2 ) were continuously recorded during simulated dynamic BH. BHDs showed a breaking point in HR kinetics at mid-BH immediately preceding a more pronounced drop in HR (-0.86 bpm.% -1 ) while HR kinetics in NDs steadily decreased throughout BH (-0.47 bpm.% -1 ). By contrast, SV remained unchanged during BH in both groups (all P > 0.05). Near-infrared spectroscopy (NIRS) results (mean ± SD) expressed as percentage changes from the initial values showed a lower [HHb] increase for BHDs than for NDs at the cessation of BH (+24.0 ± 10.1 vs. +39.2 ± 9.6%, respectively; P < 0.05). As a result, BHDs showed a [tHb] drop that NDs did not at the end of BH (-7.3 ± 3.2 vs. -3.0 ± 4.7%, respectively; P < 0.05). The most striking finding of the present study was that BHDs presented an increase in oxygen-conserving efficiency due to substantial shifts in both cardiac and peripheral haemodynamics during simulated BH. In addition, the kinetic-based approach we used provides further credence to the concept of an "oxygen-conserving breaking point" in the human diving response.

  3. Nocturnal haemoglobin oxygen desaturation in urban and rural East African paediatric cohorts with and without sickle cell anaemia: a cross-sectional study.

    PubMed

    L'Esperance, V S; Ekong, T; Cox, S E; Makani, J; Newton, C R; Soka, D; Komba, A; Kirkham, F J; Hill, C M

    2016-04-01

    Low haemoglobin oxygen saturation (SpO2) predicts complications in children with sickle cell anaemia (SCA) in the North but there are few data from Africa, where the majority of the patients reside. We measured daytime and overnight SpO2 in children with SCA in routine follow-up clinic, and controls without symptoms of SCA, comparing rural (Kilifi, Kenya) and urban (Dar-es-Salaam, Tanzania) cohorts. Daytime SpO2 was lower in 65 Tanzanian children with SCA (TS; median 97 (IQR 94-100)%); p<0.0001) than in 113 Kenyan children with SCA (KS; 99 (98-100)%) and 20 Tanzanian controls (TC; 100 (98-100)%). Compared with 95 Kenyan children with SCA, in 54 Tanzanian children with SCA and 19 TC who returned for overnight oximetry, mean (KS 99.0 (96.7-99.8)%; TS 97.9 (95.4-99.3)%; TC 98.4 (97.5-99.1)%; p=0.01) and minimum nocturnal SpO2 (92 (86-95)%; 87 (78.5-91)%; 90 (83.5-93)% p=0.0001) were lower. The difference between children with SCA persisted after adjustment for haemoglobin (p=0.004). Urban Tanzanian children, with and without SCA, experience greater exposure to low daytime and night-time SpO2 compared with rural Kenyan children with SCA. Possible explanations include differences in the prevalence of obstructive sleep apnoea or asthma, alterations in the oxyhaemoglobin desaturation curve or cardiovascular compromise, for example, to shunting at atrial or pulmonary level secondary to increased pulmonary artery pressure. The fact that non-SCA siblings in the urban area are also affected suggests that environmental exposures, for example, air pollution, nutrition or physical exercise, may play a role. Further studies should determine aetiology and clinical relevance for the SCA phenotype in children resident in Africa. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. Effects of increased inspired oxygen concentration on tissue oxygenation: theoretical considerations.

    PubMed

    Lumb, Andrew B; Nair, Sindhu

    2010-03-01

    Breathing increased fractional oxygen concentration (FiO2) is recommended for the treatment of tissue ischaemia. The theoretical benefits of increasing FiO2 on tissue oxygenation were evaluated using standard physiological equations. Assuming constant oxygen consumption by tissues throughout the length of a capillary, the oxygen content at 20 arbitrary points along a capillary was calculated. Using mathematical representations of the haemoglobin dissociation curve and an iterative approach to include the dissolved oxygen component of oxygen content, the oxygen partial pressure (PO2) profile along a capillary was estimated. High FiO2 concentrations cause large increases in PO2 at the arteriolar end of capillaries but these large PO2 values, caused by the extra dissolved oxygen, rapidly decline along the capillary. At the venular end of the capillary (the area of tissue most likely to be hypoxic), breathing oxygen causes only a modest improvement in PO2. Increasing FiO2 to treat tissue hypoxia has clear benefits, but a multimodal approach to management is required.

  5. The value of routine haemoglobin concentration measurement before caesarean section.

    PubMed

    Vashisht, A; Yentis, S

    2005-02-01

    Women undergoing caesarean section routinely have a haemoglobin concentration check before delivery. We compared the haemoglobin concentration of 311 women taken at their 32-?34 week antenatal visit with their preoperative level. A significant rise from 11.04 g/dL to 11.51 g/dL was seen (mean (95% CI) 0.47 (0.37-0.57 g/dL)). This increase was most marked in the 201 women having emergency procedures, and there was a significant negative correlation between the 32 and 34 weeks level and the net change in haemoglobin concentration (r=-0.366 (P<0.001)). From our results we suggest that in women with an otherwise uncomplicated pregnancy, and a satisfactory haemoglobin concentration at 32-34 weeks, a repeat estimation of the blood count is unnecessary before operative delivery.

  6. Study of helminthiasis in pregnancy and its correlation with haemoglobin level.

    PubMed

    K, Shrinivas; Radhika; R, Sreelatha; K, Kavitha

    2014-10-01

    To study types of worm infestation in pregnancy and to correlate helminthiasis with haemoglobin level in antenatal women presenting in 2nd and 3rd trimester. This prospective cross sectional hospital based study conducted at Vanivilas hospital attached to Bangalore medical college, over a period of sixmonths. Study included 500 pregnant women attending antenatal opd in 2nd and 3rd trimester, selected by systematic random sampling method. Parasitic examination and haemoglobin estimation done respectively with Stool and blood samples collected from study group. Presence of parasites was correlated with haemoglobin percentage. Helminthiasis was found in 62 women (12.4%). All infected women had single type helminth infection. Ascariasis was more commonly found than hookworm (10% Vs 2.4%). Anaemia of various degrees was found in 88.7% of women with helminthiasis as compared to 56.4% women without worm infestation (p-value <0.05). Helminthiasis is a significant burden in pregnancy and it is associated with anaemia. Hence, the policy of universal administration of anthelminthic drug in pregnancy after first trimester, as recommended by WHO should be practically enforced besides health education.

  7. NO and CO binding profiles of hemoglobin vesicles as artificial oxygen carriers.

    PubMed

    Sakai, Hiromi; Sato, Atsushi; Sobolewski, Peter; Takeoka, Shinji; Frangos, John A; Kobayashi, Koichi; Intaglietta, Marcos; Tsuchida, Eishun

    2008-10-01

    Hemoglobin vesicles (HbVs) are artificial oxygen carriers encapsulating purified and concentrated Hb solution in phospholipid vesicles (liposomes). We examined in-vitro reaction profiles of a formulation of HbV with NO and CO in anaerobic and aerobic conditions using stopped-flow spectrophotometry and a NO electrode. Reaction rate constants of NO to deoxygenated and oxygenated HbV were considerably smaller than those of cell-free Hb because of the intracellular NO-diffusion barrier. The reaction of CO with deoxygenated HbV was slightly slower than that of cell-free Hb solely because of the co-encapsulated allosteric effector, pyridoxal 5'-phosphate. The NO depletion in an aerobic condition in the presence of empty vesicles was monitored using a NO electrode, showing that the hydrophobic bilayer membrane of HbV, which might have higher gas solubility, does not markedly facilitate the O(2) and NO reaction, and that the intracellular Hb is the major component of NO depletion. In conclusion, HbV shows retarded gas reactions, providing some useful information to explain the absence of vasoconstriction and hypertension when they are intravenously injected.

  8. The use of haemoglobin concentrations to assess physiological condition in birds: a review

    PubMed Central

    2015-01-01

    Abstract Total blood haemoglobin concentration is increasingly being used to assess physiological condition in wild birds, although it has not been explicitly recognized how reliably this parameter reflects different components of individual quality. Thus, I reviewed over 120 published studies linking variation in haemoglobin concentrations to different measures of condition and other phenotypic or ecological traits. In most of the studied avian species, haemoglobin concentrations were positively correlated with other commonly used indices of condition, such as body mass and fat loads, as well as with quality of the diet. Also, chick haemoglobin concentrations reliably reflected the intensity of nest infestation by parasitic arthropods, and haemoglobin was suggested to reflect parasitism by haematophagous ectoparasites much more precisely than haematocrit. There was also some evidence for the negative effect of helminths on haemoglobin levels in adult birds. Finally, haemoglobin concentrations were found to correlate with such fitness-related traits as timing of arrival at breeding grounds, timing of breeding, egg size, developmental stability and habitat quality, although these relationships were not always consistent between species. In consequence, I recommend the total blood haemoglobin concentration as a relatively robust indicator of physiological condition in birds, although this parameter is also strongly affected by age, season and the process of moult. Thus, researchers are advised to control fully for these confounding effects while using haemoglobin concentrations as a proxy of physiological condition in both experimental and field studies on birds. PMID:27293692

  9. [Oxygen therapy during Argentine-based national and international flights].

    PubMed

    Martínez Fraga, Alejandro; Sívori, Martín; Alonso, Mariana

    2008-01-01

    There are no data about supplemental oxygen in flight in our country. The objective of our study was to evaluate arranging in-flight-oxygen required by a simulated traveler, system of administration and costs, and to compare the results between Argentine-based (A) and international (I) airlines. The questionnaire used was similar to that of Stoller et al12. Data collection consisted of telephone calls placed by one of the authors to all commercial air carriers listed in our two Buenos Aires City airports during July 2007. A structured interview with questions was addressed on issues that an oxygen-using air traveler would need to arrange in-flight oxygen. Of the 25 airlines, 6 were discarded because of lack of information (24%, three A -60%- and one I -16%-). All A allowed in-flight-oxygen vs. 80% of I (p<0.05), 100% of A and 94% of I required a medical certificate (p=NS); 71% of A and 100% of I required previous notification (p<0.05); 50% of A and 87% of I provided patient interphases of oxygen administration (p=NS). Free of charge oxygen could be provided by 100% of A and 50% of I, with airline charge between 70 to 300 dollars. In conclusion, we observed different policies, rules, availability, and a pronounced lack of standardization of airline information. The cost of oxygen was very different between airlines and it was superior on I. It will be necessary to carry out actions to facilitate patient access to oxygentherapy and to standardize medical information among airlines in our country.

  10. Adaptation to extreme environments: structure-function relationships in Emperor penguin haemoglobin.

    PubMed

    Tamburrini, M; Condò, S G; di Prisco, G; Giardina, B

    1994-04-15

    The functional properties of the single haemoglobin (Hb) of Emperor penguin (Aptenodytes forsteri) have been investigated at different temperatures as a function of proton and organic phosphate concentration. The complete amino acid sequence has been established. Comparison with that of human HbA shows 12 substitutions in the contact regions of alpha beta dimers. In addition to overall similarities shared with most of the avian Hbs previously described, this Hb shows significant differences, which could be related to the peculiar behaviour of this penguin. In particular we may consider that: (1) the shape of the Bohr effect curve seems well adapted for gas exchange during very prolonged dives, preserving penguin Hb from a sudden and not controlled stripping of oxygen; (2) the very minor enthalpy change observed at lower pH could be an example of molecular adaptation, through which oxygen delivery becomes essentially insensitive to exposure to the extremely low temperatures of the environment. Moreover, the small alkaline Bohr effect has been found to be only chloride-linked, since the pH dependence of the oxygen affinity is totally abolished in the absence of this ion. These functional characteristics are discussed on the basis of the primary structure of alpha and beta-chains.

  11. Increased viscosity of hemoglobin-based oxygen carriers retards NO-binding when perfused through narrow gas-permeable tubes.

    PubMed

    Sakai, Hiromi; Okuda, Naoto; Takeoka, Shinji; Tsuchida, Eishun

    2011-03-01

    Increased fluid viscosity of a solution of hemoglobin-based oxygen carriers (HBOCs) reduces vasoconstrictive effects because increased shear stress on the vascular wall enhances the production of vasorelaxation factors such as NO. Nevertheless, on a microcirculatory level, it remains unclear how viscosity affects the reaction of HBOCs and NO. In this study, different HBOCs were perfused through narrow gas-permeable tubes (25 μm inner diameter at 1 mm/s centerline velocity; hemoglobin concentration [Hb]=5 g/dL). The reaction was examined microscopically based on the Hb visible-light absorption spectrum. When immersed in a NO atmosphere, the NO-binding of deoxygenated Hb solution (viscosity, 1.1 cP at 1000 s(-1)) in the tube occurred about twice as rapidly as that of red blood cells (RBCs): 1.6 cP. Binding was reduced by PEGylation (PEG-Hb, 7.7 cP), by addition of a high molecular weight hydroxyethyl starch (HES) (2.8 cP), and by encapsulation to form Hb-vesicles (HbVs, 1.5 cP; particle size 279 nm). However, the reduction was not as great as that shown for RBCs. A mixture of HbVs and HES (6.2 cP) showed almost identical NO-binding to that of RBCs. Higher viscosity and particle size might reduce lateral diffusion when particles are flowing. The HbVs with HES showed the slowest NO-binding. Furthermore, Hb encapsulation and PEGylation, but not HES-addition, tended to retard CO-binding. Increased viscosity reportedly enhances production of endothelium NO. In addition, our results show that the increased viscosity also inhibits the reaction with NO. Each effect might mitigate vasoconstriction. Copyright © 2010 Elsevier Inc. All rights reserved.

  12. The effects of dexamethasone on post-asphyxial cerebral oxygenation in the preterm fetal sheep

    PubMed Central

    Lear, Christopher A; Koome, Miriam E; Davidson, Joanne O; Drury, Paul P; Quaedackers, Josine S; Galinsky, Robert; Gunn, Alistair J; Bennet, Laura

    2014-01-01

    Exposure to clinical doses of the glucocorticoid dexamethasone increases brain activity and causes seizures in normoxic preterm fetal sheep without causing brain injury. In contrast, the same treatment after asphyxia increased brain injury. We hypothesised that increased injury was in part mediated by a mismatch between oxygen demand and oxygen supply. In preterm fetal sheep at 0.7 gestation we measured cerebral oxygenation using near-infrared spectroscopy, electroencephalographic (EEG) activity, and carotid blood flow (CaBF) from 24 h before until 72 h after asphyxia induced by 25 min of umbilical cord occlusion. Ewes received dexamethasone intramuscularly (12 mg 3 ml–1) or saline 15 min after the end of asphyxia. Fetuses were studied for 3 days after occlusion. During the first 6 h of recovery after asphyxia, dexamethasone treatment was associated with a significantly greater fall in CaBF (P < 0.05), increased carotid vascular resistance (P < 0.001) and a greater fall in cerebral oxygenation as measured by the difference between oxygenated and deoxygenated haemoglobin (delta haemoglobin; P < 0.05). EEG activity was similarly suppressed in both groups. From 6 to 10 h onward, dexamethasone treatment was associated with a return of CaBF to saline control levels, increased EEG power (P < 0.005), greater epileptiform transient activity (P < 0.001), increased oxidised cytochrome oxidase (P < 0.05) and an attenuated increase in [delta haemoglobin] (P < 0.05). In conclusion, dexamethasone treatment after asphyxia is associated with greater hypoperfusion in the critical latent phase, leading to impaired intracerebral oxygenation that may exacerbate neural injury after asphyxia. PMID:25384775

  13. 47 CFR 63.22 - Facilities-based international common carriers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 3 2011-10-01 2011-10-01 false Facilities-based international common carriers. 63.22 Section 63.22 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER... Supplements § 63.22 Facilities-based international common carriers. The following conditions apply to...

  14. 47 CFR 63.22 - Facilities-based international common carriers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 3 2012-10-01 2012-10-01 false Facilities-based international common carriers. 63.22 Section 63.22 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER... Supplements § 63.22 Facilities-based international common carriers. The following conditions apply to...

  15. 47 CFR 63.22 - Facilities-based international common carriers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Facilities-based international common carriers. 63.22 Section 63.22 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER... Supplements § 63.22 Facilities-based international common carriers. The following conditions apply to...

  16. The role of facilitated diffusion in oxygen transport by cell-free hemoglobins: implications for the design of hemoglobin-based oxygen carriers.

    PubMed

    McCarthy, M R; Vandegriff, K D; Winslow, R M

    2001-08-30

    We compared rates of oxygen transport in an in vitro capillary system using red blood cells (RBCs) and cell-free hemoglobins. The axial PO(2) drop down the capillary was calculated using finite-element analysis. RBCs, unmodified hemoglobin (HbA(0)), cross-linked hemoglobin (alpha alpha-Hb) and hemoglobin conjugated to polyethylene-glycol (PEG-Hb) were evaluated. According to their fractional saturation curves, PEG-Hb showed the least desaturation down the capillary, which most closely matched the RBCs; HbA(0) and alpha alpha-Hb showed much greater desaturation. A lumped diffusion parameter, K*, was calculated based on the Fick diffusion equation with a term for facilitated diffusion. The overall rates of oxygen transfer are consistent with hemoglobin diffusion rates according to the Stokes-Einstein Law and with previously measured blood pressure responses in rats. This study provides a conceptual framework for the design of a 'blood substitute' based on mimicking O(2) transport by RBCs to prevent autoregulatory changes in blood flow and pressure.

  17. Predicting of the refractive index of haemoglobin using the Hybrid GA-SVR approach.

    PubMed

    Oyehan, Tajudeen A; Alade, Ibrahim O; Bagudu, Aliyu; Sulaiman, Kazeem O; Olatunji, Sunday O; Saleh, Tawfik A

    2018-04-30

    The optical properties of blood play crucial roles in medical diagnostics and treatment, and in the design of new medical devices. Haemoglobin is a vital constituent of the blood whose optical properties affect all of the optical properties of human blood. The refractive index of haemoglobin has been reported to strongly depend on its concentration which is a function of the physiology of biological cells. This makes the refractive index of haemoglobin an essential non-invasive bio-marker of diseases. Unfortunately, the complexity of blood tissue makes it challenging to experimentally measure the refractive index of haemoglobin. While a few studies have reported on the refractive index of haemoglobin, there is no solid consensus with the data obtained due to different measuring instruments and the conditions of the experiments. Moreover, obtaining the refractive index via an experimental approach is quite laborious. In this work, an accurate, fast and relatively convenient strategy to estimate the refractive index of haemoglobin is reported. Thus, the GA-SVR model is presented for the prediction of the refractive index of haemoglobin using wavelength, temperature, and the concentration of haemoglobin as descriptors. The model developed is characterised by an excellent accuracy and very low error estimates. The correlation coefficients obtained in these studies are 99.94% and 99.91% for the training and testing results, respectively. In addition, the result shows an almost perfect match with the experimental data and also demonstrates significant improvement over a recent mathematical model available in the literature. The GA-SVR model predictions also give insights into the influence of concentration, wavelength, and temperature on the RI measurement values. The model outcome can be used not only to accurately estimate the refractive index of haemoglobin but also could provide a reliable common ground to benchmark the experimental refractive index results

  18. Interpretation of HbA1c : association with mean cell volume and haemoglobin concentration.

    PubMed

    Simmons, D; Hlaing, T

    2014-11-01

    The utility of HbA1c in diabetes diagnosis is reduced in settings associated with altered haemoglobin glycation. We have studied whether HbA1c varies with mean cell volume and mean cell haemoglobin concentration as measures of haemoglobin metabolism. Randomly selected adults from rural Victoria, Australia, were invited for biomedical assessment. After excluding patients with known diabetes and/or serum creatinine ≥ 0.12 mmol/l, 1315 adults were included. Demography, arthropometric measurements, oral glucose tolerance test, analyses of full blood count and HbA1c were undertaken. After adjusting for age, sex, ethnicity, BMI, town and socio-economic status, there were no significant differences in haemoglobin, mean cell volume or mean cell haemoglobin concentration by glycaemic status (defined by oral glucose tolerance test). HbA1c was significantly and independently associated with fasting glucose, town, mean cell haemoglobin concentration, ethnicity, age and BMI among men < 50 years (R² = 33.8%); fasting glucose, 2-h glucose, mean cell haemoglobin concentration and town among men ≥ 50 years (R² = 47.9%); fasting glucose, mean cell volume, mean cell haemoglobin concentration, town, 2-h glucose and age among women < 50 years (R² = 46.3%); fasting glucose, mean cell haemoglobin concentration, mean cell volume and 2-h glucose among women ≥ 50 years (R² = 51.6%). A generalized linear model showed a gradient from an adjusted mean HbA1c of 36 (95% CI 34-38) mmol/mol with a mean cell haemoglobin concentration of ≤ 320 g/l to 30 (95% CI 29-31) mmol/mol with a mean cell haemoglobin concentration of > 370 g/l. The gradient across mean cell volume was negative, but only by 1 mmol/mol (0.1%) HbA1c . A mean HbA1c difference of 5 mmol/mol (0.5%) across the mean cell haemoglobin concentration reference range suggests that an accompanying full blood count examination may be required for its use in the diagnosis of diabetes. Further studies are required to confirm this.

  19. Reproducibility of retinal vessel oxygen saturation measurements in healthy young subjects.

    PubMed

    Lasta, Michael; Palkovits, Stefan; Boltz, Agnes; Schmidl, Doreen; Kaya, Semira; Cherecheanu, Alina Popa; Garhöfer, Gerhard; Schmetterer, Leopold

    2012-12-01

    An adequate oxygenation and perfusion is essential for the function of the inner retina. Recently, several techniques for the measurement of retinal oxygen saturation became available. We set out to evaluate reproducibility of the measurements using a modified Retinal Vessel Analyzer. A total of 20 healthy female and male subjects aged between 18 and 35 years (22.9 ± 3.9; mean ± SD) were included. The measurement of retinal oxygen saturation with the retinal oximeter employed in this study is based on optical reflectometry using the different absorption characteristics of oxygenated and deoxygenated haemoglobin. The intraclass correlation coefficients and the coefficients of variation (CV) for test-retest, short-term as well as day-to-day measurements were calculated.   The intraclass correlation coefficients were between 0.91 and 0.94 for retinal branch arteries and between 0.84 and 0.88 for retinal branch veins. In retinal arteries, we calculated a test-retest CV of 3.24 ± 3.18% for oxygen saturation measurements. In retinal veins, data were slightly less reproducible with a CV of 4.92 ± 3.57%. Short-term reproducibility of both measurement cycles on each study day was in the same range (CV in retinal arteries: 2.91 ± 2.42% and CV in retinal veins: 4.76 ± 3.14%). The day-to-day coefficient of variation was slightly higher (CV in retinal arteries: 3.97 ± 2.87% and CV in retinal veins: 6.18 ± 3.36%). The reproducibility of haemoglobin oxygen saturation measurements using the retinal oximeter is acceptable. Further studies on the validity of the obtained results are, however, required. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  20. The binding of carbon dioxide by horse haemoglobin

    PubMed Central

    Kilmartin, J. V.; Rossi-Bernardi, L.

    1971-01-01

    1. Three modified horse haemoglobins have been prepared: (i) αc2βc2, in which both the α-amino groups of the α- and β-chains have reacted with cyanate, (ii) αc2β2, in which the α-amino groups of the α-chains have reacted with cyanate, and (iii) α2βc2, in which the two α-amino groups of the β-chain have reacted with cyanate. 2. The values of n (the Hill constant) for αc2βc2, α2βc2 and αc2β2 were (respectively) 2.5, 2.0 and 2.6, indicating the presence of co-operative interactions between the haem groups for all derivatives. 3. In the alkaline pH range (about pH8.0) all the derivatives show the same charge as normal haemoglobin whereas in the acid pH range (about pH6.0) αc2βc2 differs by four protonic charges and αc2β2, α2βc2 by two protonic charges from normal haemoglobin, indicating that the expected number of ionizing groups have been removed. 4. αc2β2 and αc2βc2 show a 25% decrease in the alkaline Bohr effect, in contrast with α2βc2, which has the same Bohr effect as normal haemoglobin. 5. The deoxy form of αc2βc2 does not bind more CO2 than the oxy form of αc2βc2, whereas αc2β2 and α2βc2 show intermediate binding. 6. The results reported confirm the hypothesis that, under physiological conditions, haemoglobin binds CO2 through the four terminal α-amino groups and that the two terminal α-amino groups of α-chains are involved in the Bohr effect. ImagesPLATE 1 PMID:5166592

  1. Evaluation of two-step haemoglobin screening with HemoCue for blood donor qualification in mobile collection sites.

    PubMed

    Gómez-Simón, A; Plaza, E M; Torregrosa, J M; Ferrer-Marín, F; Sánchez-Guiu, I; Vicente, V; Lozano, M L; Rivera, J

    2014-11-01

    Inaccuracy of fingerstick haemoglobin compromises donor's health and losses blood donations. We evaluated the benefit of double haemoglobin screening with HemoCue. Blood donors underwent fingerstick screening by HemoCue and were driven for donation if capillary haemoglobin was within the regulatory range. Those failing were drawn venous blood and donated if their venous haemoglobin determined with HemoCue was acceptable. Of 276 605 donor clinic visits, 10 011 (3·6%) were assessed by two-step haemoglobin screening using HemoCue, because of low (n = 9444) or high (n = 567) capillary haemoglobin. Among these, 2561 (25·6%) were deemed eligible [recovered donations]. The recovery rate was 23·8% and 55·0% among donors presenting with low and high capillary haemoglobin, respectively. In both categories of attempted donations, capillary and venous haemoglobin with HemoCue correlated significantly in recovered donors (R(2)  ≈ 0·5-0·7) but not in deferred visits (R(2)  < 0·15). Venous haemoglobin with HemoCue and by haematological analyzer significantly correlated in all donations attempts (R(2)  ≈ 0·7). Donors presenting with low capillary haemoglobin showed small bias between capillary and venous haemoglobin by HemoCue (-2·4 ± 6·2 g/l), fingerstick haemoglobin and venous haemoglobin with counter (1·3 ± 7·3 g/l), and venous haemoglobin with HemoCue and counter (3·7 ± 3·9 g/l). This bias was slightly greater in donors with high capillary haemoglobin (-7·5 ± 7·8, 13·7 ± 7·5, and 6·2 ± 7·5, respectively). Double haemoglobin screening by HemoCue reached an accuracy of 87·3% for qualifying donors presenting with low fingerstick haemoglobin. Double haemoglobin measurement with HemoCue [fingerstick and venous blood if required] is feasible and allows a significant recovery of blood donations. © 2014 International Society of Blood Transfusion.

  2. Optimal haematocrit in subjects with normal haemoglobin genotype (HbAA), sickle cell trait (HbAS), and homozygous sickle cell disease (HbSS).

    PubMed

    Bowers, A S; Pepple, D J; Reid, H L

    2011-01-01

    The determination of an optimal haematocrit (H0) has important clinical implications if such a level can be attained, and more importantly, maintained. This is defined as a haematocrit level, above or below which oxygen delivery is deleteriously affected. This study is designed to determine an optimal haematocrit in normal (AA), sickle cell trait (AS) and sickle cell disease (SS) subjects. Twenty-seven apparently healthy subjects having normal haemoglobin genotype, 24 with sickle cell trait and 42 with homozygous sickle cell disease were recruited into the study. Whole blood viscosity (WBV) was measured by a Wells Brookfield Cone and Plate Viscometer at a shear rate of 230 sec-1. Haematocrit was determined by an AC.Tron Coulter Counter. The optimal haematocrit was calculated as the inverse of a constant, K, which was derived from the haematocrit and viscosity data. Our findings showed that the H0 varied significantly among the 3 haemoglobin genotypes, in the order AA vs SS and AS vs SS. Additionally, the data indicated an increased H0 in subjects with sickle cell trait, suggesting a possible impairment in oxygen delivery in these individuals.

  3. [Hemoglobin, from microorganisms to man: a single structural motif, multiple functions].

    PubMed

    Wajcman, Henri; Kiger, Laurent

    2002-12-01

    Haemoglobins from unicellular organisms, plants or animals, share a common structure, which results from the folding, around the heme group, of a polypeptide chain made from 6-8 helices. Nowadays, deciphering the genome of several species allows one to draw the evolutionary tree of this protein going back to 1800 millions of years, at a time when oxygen began to accumulate in the atmosphere. This permits to follow the evolution of the ancestral gene and of its product. It is likely that, only in complex multicellular species, transport and storage of oxygen became the main physiological function of this molecule. In addition, in unicellular organisms and small invertebrates, it is likely that the main function of this protein was to protect the organism from the toxic effect of O2, CO and NO*. The very high oxygen affinity of these molecules, leading them to act rather as a scavenger as an oxygen carrier, supports this hypothesis. Haemoglobins from microorganisms, which may probably be the closest vestiges to the ancestral molecules, are divided into three families. The first one is made from flavohaemoglobins, a group of chimerical proteins carrying a globin domain and an oxido-reduction FAD-dependant domain. The second corresponds to truncated haemoglobins, which are hexacoordinated with very high oxygen-affinity molecules, 20-40 residues shorter than classical haemoglobins. The third group is made from bacterial haemoglobins such as that of Vitreoscilla. Some specific structural arrangements in the region surrounding the heme are cause of their high oxygen affinity. In plants, two types of haemoglobins are present (non-symbiotic and symbiotic), that arose from duplication of an ancestral vegetal gene. Non-symbiotic haemoglobins, which are probably the oldest, are scarcely distributed within tissues having high energetic consumption. Conversely, symbiotic haemoglobins (also named leghaemoglobins) are present at a high concentration (mM) mostly in the rhizomes of

  4. Accuracy of noninvasive haemoglobin measurement by pulse oximetry depends on the type of infusion fluid.

    PubMed

    Bergek, Christian; Zdolsek, Joachim H; Hahn, Robert G

    2012-12-01

    Measurement of blood haemoglobin concentration by pulse oximetry could be of value in determining when erythrocytes should be transfused during surgery, but the effect of infusion fluids on the results is unclear. To study the effect of crystalloid and colloid fluid on the accuracy (bias) and precision of pulse oximetry haemoglobin estimation to indicate the venous haemoglobin concentration in volunteers. Open interventional crossover study. Single university hospital. Ten male volunteers aged 18-28 (mean 22) years. Each volunteer underwent three infusion experiments on separate days and in random order. The infusions were Ringer's acetate (20 ml kg), hydroxyethyl starch 130/0.4 (10 ml kg) and a combination of both. At the end of the infusions of Ringer's acetate, pulse oximetry haemoglobin concentration had decreased more than the true haemoglobin concentration (15 vs. 8%; P < 0.005; n = 10) whereas starch solution decreased pulse oximetry haemoglobin concentration less than true haemoglobin concentration (7 vs. 11%; P < 0.02; n = 20). The same differences were seen when the fluids were infused separately and when they were combined. The overall difference between all 956 pairs of pulse oximetry haemoglobin concentration and true haemoglobin concentrations (the bias) averaged only -0.7 g l whereas the 95% prediction interval was wide, ranging from -24.9 to 23.7 g l. In addition to the choice of infusion fluid, the bias was strongly dependent on the volunteer (each factor, P < 0.001). The bias of measuring haemoglobin concentration by pulse oximetry is dependent on whether a crystalloid or a colloid fluid is infused. Trial registration ClinicalTrials identifier: NCT01195025.

  5. Febrile Convulsion among Hospitalized Children Aged Six Months to Five Years and Its Association With Haemoglobin Electrophoretic Pattern.

    PubMed

    Adeboye, M; Ojuawo, A; Adeniyi, A; Ibraheem, R M; Amiwero, C

    2015-07-01

    Febrile convulsion and sickle cell disease are common in tropical countries and both are associated with significant morbidity and mortality. Worldwide, Nigeria has the highest prevalence of sickle cell disease. However, there is a dearth of knowledge on the haemoglobin electrophoresis in patients with febrile convulsions. This was a hospital based, descriptive, cross-sectional study of the relationship between haemoglobin genotype and febrile convulsion at the University of Ilorin Teaching Hospital over a period of 12 months. A self-designed pretested questionnaire was administered on the subjects, and necessary examinations and investigations were conducted. Of a total of 1675 children admitted into the emergency paediatric unit during the study period, children aged 6 months-5 years that presented with febrile convulsions were 167(10%). Of this, 1,212 were aged 6 months-5 years. Thus, the age specific, hospital-based prevalence was 13.8%. The M:F was 1.1:1. Their Haemoglobin genotype distribution was AA 131(78.4%), AS 23(13.8%), AC 6(3.6%), SS 6(3.6%), and 1(0.6%) SC. The mean age of the sickle cell disease patients was higher at 46.0±13.5 months compared to 29.2±15.4 months in the non-sickle cell disease patients (p=0.005). The mean packed cell volume in subjects with sickle cell anaemia was 8.8±1.5%; the only case of haemoglobin SC had packed cell volume of 20%, while the non-sickle cell disease patients had a normal PCV. Malaria was present in 80.4% of them. Febrile convulsion remains a common cause of hospitalisation. It is uncommon in haemoglobin SS where severe anaemia is always an accompanying derangement. The packed cell volume is nearly normal in children with normal haemoglobin genotype.

  6. 'Multi-associations': predisposed to misinterpretation of peripheral tissue oxygenation and circulation in neonates.

    PubMed

    Pichler, Gerhard; Pocivalnik, Mirjam; Riedl, Regina; Pichler-Stachl, Elisabeth; Morris, Nicholas; Zotter, Heinz; Müller, Wilhelm; Urlesberger, Berndt

    2011-08-01

    Interpretation of peripheral circulation in ill neonates is crucial but difficult. The aim was to analyse parameters potentially influencing peripheral oxygenation and circulation. In a prospective observational cohort study in 116 cardio-circulatory stable neonates, peripheral muscle near-infrared spectroscopy (NIRS) with venous occlusion was performed. Tissue oxygenation index (TOI), mixed venous oxygenation (SvO(2)), fractional oxygen extraction (FOE), fractional tissue oxygen extraction (FTOE), haemoglobin flow (Hbflow), oxygen delivery (DO(2)), oxygen consumption (VO(2)), and vascular resistance (VR) were assessed. Correlation coefficients between NIRS parameters and demographic parameters (gestational age, birth weight, age, actual weight, diameter of calf, subcutaneous adipose tissue), monitoring parameters (heart rate, arterial oxygen saturation (SaO(2)), mean blood pressure (MAP), core/peripheral temperature, central/peripheral capillary refill time) and laboratory parameters (haemoglobin concentration (Hb-blood), pCO(2)) were calculated. All demographic parameters except for Hbflow and DO(2) correlated with NIRS parameters. Heart rate correlated with TOI, SvO(2), VO(2) and VR. SaO(2) correlated with FOE/FTOE. MAP correlated with Hbflow, DO(2), VO(2) and VR. Core temperature correlated with FTOE. Peripheral temperature correlated with all NIRS parameters except VO(2). Hb-blood correlated with FOE and VR. pCO(2) levels correlated with TOI and SvO(2). The presence of multiple interdependent factors associated with peripheral oxygenation and circulation highlights the difficulty in interpreting NIRS data. Nevertheless, these findings have to be taken into account when analysing peripheral oxygenation and circulation data.

  7. 47 CFR 63.22 - Facilities-based international common carriers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... through post facto remedies, the International Bureau may impose temporary requirements on carriers.... 63.22 Section 63.22 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER... Supplements § 63.22 Facilities-based international common carriers. The following conditions apply to...

  8. 47 CFR 63.22 - Facilities-based international common carriers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... through post facto remedies, the International Bureau may impose temporary requirements on carriers.... 63.22 Section 63.22 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER... Supplements § 63.22 Facilities-based international common carriers. The following conditions apply to...

  9. Polyethylene Based Materials for Biofilm Carriers Used in Wastewater Treatment

    NASA Astrophysics Data System (ADS)

    Moga, I. C.; Iordache, O. I.; Petrescu, G.; Pricop, F.; Dumitrescu, I.

    2018-06-01

    The moving bed biofilm technology is based on biofilm carriers on which consortia of microorganisms attach, develop and grow. Around the world are known many biofilm carrier variants made of varied materials. The most common materials are based on polyethylene since this material has a close to water density. The authors propose a novel biofilm carrier to be used in tertiary treatment for tannery and paper-mill wastewaters. The biological treatment is based on fungal activity. The selected fungal strains will be grown on innovative polyethylene carriers containing cellulose. The carrier will be designed to be exploited in a moving bed bioreactor and to favour fungal growth in the presence of competing bacteria.

  10. Effect of dissolved oxygen on heterotrophic denitrification using poly(butylene succinate) as the carbon source and biofilm carrier.

    PubMed

    Luo, Guozhi; Li, Li; Liu, Qian; Xu, Guimei; Tan, Hongxin

    2014-11-01

    The effect of dissolved oxygen (DO) on heterotrophic denitrification using poly(butylene succinate) as the carbon source and biofilm carrier was evaluated in a lab-scale experiment. Aerated, low-oxygen, and anoxic treatment groups were set up, which had average DO concentrations of 5.2±1.0, 1.4±1.2, and 0.5±0.3 mg L(-1), respectively. The NO3(-)-N and total nitrogen (TN) removal rates in the aerated group (37.44±0.24 and 36.24±0.48 g m(-3) d(-1), respectively) were higher than those in the other two groups. There was no significant difference between the low-oxygen and anoxic groups for the NO3(-)-N or TN removal rate. Accumulation of NO2(-)-N reached 5.0 mg L(-1) in the aerated group; no nitrite accumulation was found in the other two treatment groups. Bacterial communities of the low-oxygen and anoxic groups showed high similarity and were significantly different from those of the aerated group. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Haemoglobin Levels in Acute Coronary Syndrome Patients Admitted in Cardiology Intensive Care Units in a Tertiary Care Hospital.

    PubMed

    Naqvil, Syed Mujtaba Hussain; Rao, T Ramesh Kumar; Chandra, Shobha Jagdish

    2015-06-01

    Epidemiology of abnormal haemoglobin levels and its association with severity of coronary artery disease in Indian patients is uncertain. This prospective observational study was conducted to determine the haemoglobin levels in acute coronary syndrome (ACS) patients and the association of anaemia with the severity of coronary artery disease (CAD) on coronary angiography (CAG). The patients diagnosed with ACS (ST-elevated and non-elevated MI, unstable angina) based on ECG and cardiac enzymes and admitted in cardiology ICU were enrolled in the study after fulfilling study criteria and the baseline haemoglobin level was recorded. The severity of coronary disease of patients who underwent coronary angiography was recorded. A total of 162 patients were enrolled for the study. The overall haemoglobin of patients was 11.99 ± 2.24 g/dl with 12.46 ± 2.33 g/dl in males and 11.17 ± 1.82 g/dl in females (p < 0.05). Anaemia was found in 62.96% patients with no significant gender difference (p > 0.05), however abnormal haemoglobin level (Hb > 16g/dl) was found exclusively in 7.7% males. One hundred one patients underwent coronary angiography and anaemia was present in 60 patients (58.82%) and absent in 41 (40.59%). The difference in mean haemoglobin levels in anaemic patients with single, double, and triple vessel disease was significant (p < 0.05) and corresponding levels in non-anaemic patients were insignificant (p > 0.05). A weak correlation was observed between the haemoglobin level of patients and the percentage of obstruction in CAG (r = 0.26). The odds of having triple vessel disease in anaemic patient are 1.77 (95% CI 0.71 to 4.43). However, the association between anaemia and the severity of coronary artery disease was statistically found to be non-significant. The mean haemoglobin levels decreased as the severity of CAD increased in CAG, however the association was not established between anaemia and the severity of coronary artery disease statistically.

  12. Thalassaemia screening and confirmation of carriers in parents.

    PubMed

    Barrett, Angela N; Saminathan, Ramasamy; Choolani, Mahesh

    2017-02-01

    Haemoglobinopathies are among the most common inherited monogenic disorders worldwide. Thalassaemia screening for carrier status is recommended for adults of reproductive age if suspected of being at risk. Conventional laboratory methods for screening include the assessment of haematological indices, and high-performance liquid chromatography, capillary electrophoresis or isoelectric focusing to measure the levels of HbA 2 and HbF, and to identify haemoglobin variants. Each screening method has its advantages and disadvantages, the main disadvantage being that none can fully resolve all variants. The complex nature of the genetics of haemoglobinopathies necessitates expertise in the interpretation of screening results to evaluate the most likely genotypes, which must then be confirmed using the DNA diagnosis. This review highlights the limits and pitfalls of each screening technique, and outlines a rational combination of different methods to overcome issues in thalassaemia carrier detection. Copyright © 2016. Published by Elsevier Ltd.

  13. Faecal haemoglobin concentration is related to detection of advanced colorectal neoplasia in the next screening round.

    PubMed

    Digby, Jayne; Fraser, Callum G; Carey, Francis A; Diament, Robert H; Balsitis, Margaret; Steele, Robert Jc

    2017-06-01

    Objective To examine associations between faecal haemoglobin concentrations below the cut-off used in colorectal cancer screening and outcomes in the next screening round. Methods In the Scottish Bowel Screening Programme, faecal haemoglobin concentrations and diagnostic outcomes were investigated for participants with a negative result (faecal haemoglobin concentrations < 80.0 µg Hb/g faeces), followed by a positive result within two years. Results Of 37,780 participants with negative results, at the next screening round, 556 (1.5%) screened positive and 30,293 (80.2%) negative. Initial median faecal haemoglobin concentrations (2.1 µg Hb/g faeces, IQR: 0.0-13.2) were higher in those with subsequent positive results than those with subsequent negative results (0.0 µg Hb/g faeces, IQR: 0.0-1.4; p < 0.0001). Using faecal haemoglobin concentrations 0.0-19.9 µg Hb/g faeces as reference, logistic regression analysis showed high adjusted odds ratios for advanced neoplasia (advanced neoplasia: colorectal cancer or higher risk adenoma) detection at the next round of 14.3 (95% CI: 8.9-23.1) in those with initial faecal haemoglobin concentrations 20.0-39.9 µg Hb/g faeces, and 38.0 (95% CI: 20.2-71.2) with 60.0-79.9 µg Hb/g faeces. Conclusions A higher proportion of participants with faecal haemoglobin concentrations of ≥ 20 µg Hb/g faeces had advanced neoplasia detected at the next round than participants with lower faecal haemoglobin concentrations. Although most relevant when using high faecal haemoglobin concentrations cut-offs, studies of faecal haemoglobin concentrations and outcomes over screening rounds may provide strategies to direct available colonoscopy towards those at highest risk.

  14. Evaluation of haemoglobin in blister fluid as an indicator of paediatric burn wound depth.

    PubMed

    Tanzer, Catherine; Sampson, Dayle L; Broadbent, James A; Cuttle, Leila; Kempf, Margit; Kimble, Roy M; Upton, Zee; Parker, Tony J

    2015-08-01

    The early and accurate assessment of burns is essential to inform patient treatment regimens; however, this first critical step in clinical practice remains a challenge for specialist burns clinicians worldwide. In this regard, protein biomarkers are a potential adjunct diagnostic tool to assist experienced clinical judgement. Free circulating haemoglobin has previously shown some promise as an indicator of burn depth in a murine animal model. Using blister fluid collected from paediatric burn patients, haemoglobin abundance was measured using semi-quantitative Western blot and immunoassays. Although a trend was observed in which haemoglobin abundance increased with burn wound severity, several patient samples deviated significantly from this trend. Further, it was found that haemoglobin concentration decreased significantly when whole cells, cell debris and fibrinous matrix was removed from the blister fluid by centrifugation; although the relationship to depth was still present. Statistical analyses showed that haemoglobin abundance in the fluid was more strongly related to the time between injury and sample collection and the time taken for spontaneous re-epithelialisation. We hypothesise that prolonged exposure to the blister fluid microenvironment may result in an increased haemoglobin abundance due to erythrocyte lysis, and delayed wound healing. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  15. Rockets using Liquid Oxygen

    NASA Technical Reports Server (NTRS)

    Busemann, Adolf

    1947-01-01

    It is my task to discuss rocket propulsion using liquid oxygen and my treatment must be highly condensed for the ideas and experiments pertaining to this classic type of rocket are so numerous that one could occupy a whole morning with a detailed presentation. First, with regard to oxygen itself as compared with competing oxygen carriers, it is known that the liquid state of oxygen, in spite of the low boiling point, is more advantageous than the gaseous form of oxygen in pressure tanks, therefore only liquid oxygen need be compared with the oxygen carriers. The advantages of liquid oxygen are absolute purity and unlimited availability at relatively small cost in energy. The disadvantages are those arising from the impossibility of absolute isolation from heat; consequently, allowance must always be made for a certain degree of vaporization and only vented vessels can be used for storage and transportation. This necessity alone eliminates many fields of application, for example, at the front lines. In addition, liquid oxygen has a lower specific weight than other oxygen carriers, therefore many accessories become relatively larger and heavier in the case of an oxygen rocket, for example, the supply tanks and the pumps. The advantages thus become effective only in those cases where definitely scheduled operation and a large ground organization are possible and when the flight requires a great concentration of energy relative to weight. With the aim of brevity, a diagram of an oxygen rocket will be presented and the problem of various component parts that receive particularly thorough investigation in this classic case but which are also often applicable to other rocket types will be referred to.

  16. Nitric oxide-fixation by non-symbiotic haemoglobin proteins in Arabidopsis thaliana under N-limited conditions.

    PubMed

    Kuruthukulangarakoola, Gitto Thomas; Zhang, Jiangli; Albert, Andreas; Winkler, Barbro; Lang, Hans; Buegger, Franz; Gaupels, Frank; Heller, Werner; Michalke, Bernhard; Sarioglu, Hakan; Schnitzler, Jörg-Peter; Hebelstrup, Kim Henrik; Durner, Jörg; Lindermayr, Christian

    2017-01-01

    Nitric oxide (NO) is an important signalling molecule that is involved in many different physiological processes in plants. Here, we report about a NO-fixing mechanism in Arabidopsis, which allows the fixation of atmospheric NO into nitrogen metabolism. We fumigated Arabidopsis plants cultivated in soil or as hydroponic cultures during the whole growing period with up to 3 ppmv of NO gas. Transcriptomic, proteomic and metabolomic analyses were used to identify non-symbiotic haemoglobin proteins as key components of the NO-fixing process. Overexpressing non-symbiotic haemoglobin 1 or 2 genes resulted in fourfold higher nitrate levels in these plants compared with NO-treated wild-type. Correspondingly, rosettes size and weight, vegetative shoot thickness and seed yield were 25, 40, 30, and 50% higher, respectively, than in wild-type plants. Fumigation with 250 ppbv 15 NO confirmed the importance of non-symbiotic haemoglobin 1 and 2 for the NO-fixation pathway, and we calculated a daily uptake for non-symbiotic haemoglobin 2 overexpressing plants of 250 mg N/kg dry weight. This mechanism is probably important under conditions with limited N supply via the soil. Moreover, the plant-based NO uptake lowers the concentration of insanitary atmospheric NOx, and in this context, NO-fixation can be beneficial to air quality. © 2016 The Authors Plant, Cell & Environment Published by John Wiley & Sons Ltd.

  17. Drug carrier in cancer therapy: A simulation study based on magnetic carrier substances

    NASA Astrophysics Data System (ADS)

    Adam, Tijjani; Dhahi, Th S.; Mohammed, Mohammed; Hashim, U.; Noriman, N. Z.; Dahham, Omar S.

    2017-09-01

    The principle of magnetic carrier is a medium for transferring information by sending the drug to the specific part to kill tumor cells. Generally, there are seven stages of cancer. Most of the patient with cancer can only be detected when reaches stage four. At that stage, the cancer is difficult to destroy or to cure. Comparing to the nearly stage, there are probability to destroy tumor cell completely by sending the drug through magnetic carrier directly to nerve. Another way to destroyed tumor completely is by using Deoxyribonucleic acid (DNA). This project is about the simulation study based on magnetic carrier substances. The COMSOL multiphysic software is used in this project. The simulation model represents a permanent magnet, blood vessel, surrounding tissues and air in 2D. Based on result obtained, the graph shown during sending the magnetic flux is high. However, as its carry information the magnetic flux reducess from the above, the move from 0m until 0.009 m it become the lowers and start increase the flux from this until maximum at 0.018m. This is due the fact that carrier start to increase after because the low information is gradually reduce until 0.018m.

  18. Routine screening for α-thalassaemia using an immunochromatographic strip assay for haemoglobin Bart's.

    PubMed

    Prayalaw, Patcharawadee; Fucharoen, Goonnapa; Fucharoen, Supan

    2014-09-01

    To evaluate an immunochromatographic (IC) strip assay for Hb Bart's as a routine screening test for α-thalassaemia in area with a high prevalence of thalassaemia and haemoglobinopathies. A total of 300 adult screen positive blood specimens were collected at an ongoing thalassaemia screening programme in northeast Thailand. Routine screening was done using red blood cell indices, osmotic fragility, and dichlorophenolindophenol tests. The IC strip assay for haemoglobin Bart's was performed on all samples. The result was evaluated against thalassaemia genotypes determined using standard haemoglobin and DNA analyses. Of 300 subjects investigated, Hb and DNA analyses identified 32 with normal genotype. The remaining subjects carried thalassaemia with as many as 16 different genotypes. Hb Bart's was detected in all cases, with several α(0)-thalassaemia (SEA type) related disorders. Of cases with α(+)-thalassaemia, 86.1% showed a positive result; 100 out of 103 Hb E carriers, all homozygous Hb E and β-thalassaemia trait were negative. Nine out of 17 cases with β-thalassaemia/Hb E disease, and one case of double heterozygote for Hb Q-Thailand and Hb E returned positive results. The overall sensitivity and specificity of the IC strip assay for detecting α(0)-thalassaemia were 100% and 73.1%, respectively. The results showed a high sensitivity for screening for α(0)-thalassaemia using IC strip assay for Hb Bart's. This simple method, used in combination with conventional screening protocols, should lead to a significant reduction in the number of referral cases for DNA analysis. Cost effectiveness in each population should be taken into consideration. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  19. Oxygen vacancies promoted interfacial charge carrier transfer of CdS/ZnO heterostructure for photocatalytic hydrogen generation.

    PubMed

    Xie, Ying Peng; Yang, Yongqiang; Wang, Guosheng; Liu, Gang

    2017-10-01

    The solid-state Z-scheme trinary/binary heterostructures show the advantage of utilizing the high-energy photogenerated charge carriers in photocatalysis. However, the key factors controlling such Z-scheme in the binary heterostructures are still unclear. In this paper, we showed that oxygen vacancies could act as an interface electron transfer mediator to promote the direct Z-scheme charge transfer process in binary semiconductor heterostructures of CdS/ZnS. Increasing the concentration of surface oxygen vacancies of ZnO crystal can greatly enhance photocatalytic hydrogen generation of CdS/ZnO heterostructure. This was attributed to the strengthened direct Z-scheme charge transfer process in CdS/ZnO, as evidenced by steady-state/time-resolved photoluminescence spectroscopy and selective photodeposition of metal particles on the heterostructure. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Sea-level haemoglobin concentration is associated with greater exercise capacity in Tibetan males at 4200 m.

    PubMed

    Wagner, P D; Simonson, T S; Wei, G; Wagner, H E; Wuren, T; Qin, G; Yan, M; Ge, R L

    2015-11-01

    What is the topic of this review? Recent developments link relatively lower hemoglobin concentration in Tibetans at high altitude to exercise capacity and components of oxygen transport. What advances does it highlight? Haemoglobin concentration (ranging from 15.2 to 22.9 g dl(-1) ) in Tibetan males was negatively associated with peak oxygen (O2 ) uptake per kilogram, cardiac output and muscle O2 diffusion conductance. Most variance in the peak O2 uptake per kilogram of Tibetan males was attributed to cardiac output, muscle diffusional conductance and arterial partial pressure of CO2 . The mechanisms underlying these differences in oxygen transport in Tibetans require additional analyses. Despite residence at >4000 m above sea level, many Tibetan highlanders, unlike Andean counterparts and lowlanders at altitude, exhibit haemoglobin concentration ([Hb]) within the typical sea-level range. Genetic adaptations in Tibetans are associated with this relatively low [Hb], yet the functional relevance of the lower [Hb] remains unknown. To address this, we examined each major step of the oxygen transport cascade [ventilation (VE), cardiac output (QT) and diffusional conductance in lung (DL) and muscle (DM)] in Tibetan males at maximal exercise on a cycle ergometer. Ranging from 15.2 to 22.9 g dl(-1) , [Hb] was negatively associated with peak O2 uptake per kilogram (r = -0.45, P < 0.05) and both cardiac output (QT/kg: r = -0.54, P < 0.02) and muscle O2 diffusion conductance (DM/kg: r = -0.44, P < 0.05) but not ventilation, arterial partial pressure of O2 or pulmonary diffusing capacity. Most variance in peak O2 uptake per kilogram was attributed to QT, DM and arterial partial pressure of CO2 (r(2)  = 0.90). In summary, lack of polycythaemia in Tibetans is associated with increased exercise capacity, which is explained by elevated cardiac, muscle and, to a small extent, ventilatory responses rather than pulmonary gas exchange. Whether lower [Hb] is the

  1. Effect of sample storage temperature and buffer formulation on faecal immunochemical test haemoglobin measurements.

    PubMed

    Symonds, Erin L; Cole, Stephen R; Bastin, Dawn; Fraser, Robert Jl; Young, Graeme P

    2017-12-01

    Objectives Faecal immunochemical test accuracy may be adversely affected when samples are exposed to high temperatures. This study evaluated the effect of two sample collection buffer formulations (OC-Sensor, Eiken) and storage temperatures on faecal haemoglobin readings. Methods Faecal immunochemical test samples returned in a screening programme and with ≥10 µg Hb/g faeces in either the original or new formulation haemoglobin stabilizing buffer were stored in the freezer, refrigerator, or at room temperature (22℃-24℃), and reanalysed after 1-14 days. Samples in the new buffer were also reanalysed after storage at 35℃ and 50℃. Results were expressed as percentage of the initial concentration, and the number of days that levels were maintained to at least 80% was calculated. Results Haemoglobin concentrations were maintained above 80% of their initial concentration with both freezer and refrigerator storage, regardless of buffer formulation or storage duration. Stability at room temperature was significantly better in the new buffer, with haemoglobin remaining above 80% for 20 days compared with six days in the original buffer. Storage at 35℃ or 50℃ in the new buffer maintained haemoglobin above 80% for eight and two days, respectively. Conclusion The new formulation buffer has enhanced haemoglobin stabilizing properties when samples are exposed to temperatures greater than 22℃.

  2. Haemoglobin variants, iron status and anaemia in Sri Lankan adolescents with low red cell indices: A cross sectional survey.

    PubMed

    Rodrigo, Rexan; Allen, Angela; Manampreri, Aresha; Perera, Luxman; Fisher, Christopher A; Allen, Stephen; Weatherall, David J; Premawardhena, Anuja

    2018-07-01

    Iron deficiency complicates the use of red cell indices to screen for carriers of haemoglobin variants in many populations. In a cross sectional survey of 7526 secondary school students from 25 districts of Sri Lanka, 1963 (26.0%) students had low red cell indices. Iron deficiency, identified by low serum ferritin, was the major identifiable cause occurring in 550/1806 (30.5%) students. Low red cell indices occurred in iron-replete students with alpha-thalassaemia including those with single alpha-globin gene deletions. Anaemia and low red cell indices were also common in beta-thalassaemia trait. An unexpected finding was that low red cell indices occurred in 713 iron-replete students with a normal haemoglobin genotype. It is common practice to prescribe iron supplements to individuals with low red cell indices. Since low red cell indices were a feature of all forms of α thalassaemia and also of iron deficiency, in areas where both conditions are common, such as Sri Lanka, it is imperative to differentiate between the two, to allow targeted administration of iron supplements and avoid the possible deleterious effects of increased iron availability in iron replete individuals with low red cell indices due to other causes such as α thalassaemia. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. EMQN Best Practice Guidelines for molecular and haematology methods for carrier identification and prenatal diagnosis of the haemoglobinopathies.

    PubMed

    Traeger-Synodinos, Joanne; Harteveld, Cornelis L; Old, John M; Petrou, Mary; Galanello, Renzo; Giordano, Piero; Angastioniotis, Michael; De la Salle, Barbara; Henderson, Shirley; May, Alison

    2015-04-01

    Haemoglobinopathies constitute the commonest recessive monogenic disorders worldwide, and the treatment of affected individuals presents a substantial global disease burden. Carrier identification and prenatal diagnosis represent valuable procedures that identify couples at risk for having affected children, so that they can be offered options to have healthy offspring. Molecular diagnosis facilitates prenatal diagnosis and definitive diagnosis of carriers and patients (especially 'atypical' cases who often have complex genotype interactions). However, the haemoglobin disorders are unique among all genetic diseases in that identification of carriers is preferable by haematological (biochemical) tests rather than DNA analysis. These Best Practice guidelines offer an overview of recommended strategies and methods for carrier identification and prenatal diagnosis of haemoglobinopathies, and emphasize the importance of appropriately applying and interpreting haematological tests in supporting the optimum application and evaluation of globin gene DNA analysis.

  4. EMQN Best Practice Guidelines for molecular and haematology methods for carrier identification and prenatal diagnosis of the haemoglobinopathies

    PubMed Central

    Traeger-Synodinos, Joanne; Harteveld, Cornelis L; Old, John M; Petrou, Mary; Galanello, Renzo; Giordano, Piero; Angastioniotis, Michael; De la Salle, Barbara; Henderson, Shirley; May, Alison

    2015-01-01

    Haemoglobinopathies constitute the commonest recessive monogenic disorders worldwide, and the treatment of affected individuals presents a substantial global disease burden. Carrier identification and prenatal diagnosis represent valuable procedures that identify couples at risk for having affected children, so that they can be offered options to have healthy offspring. Molecular diagnosis facilitates prenatal diagnosis and definitive diagnosis of carriers and patients (especially ‘atypical' cases who often have complex genotype interactions). However, the haemoglobin disorders are unique among all genetic diseases in that identification of carriers is preferable by haematological (biochemical) tests rather than DNA analysis. These Best Practice guidelines offer an overview of recommended strategies and methods for carrier identification and prenatal diagnosis of haemoglobinopathies, and emphasize the importance of appropriately applying and interpreting haematological tests in supporting the optimum application and evaluation of globin gene DNA analysis. PMID:25052315

  5. Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions.

    PubMed

    Abay, T Y; Kyriacou, P A

    2018-06-01

    Photoplethysmography (PPG) is an optical technique that measures blood volume variations. The main application of dual-wavelength PPG is pulse oximetry, in which the arterial oxygen saturation (SpO[Formula: see text]) is calculated noninvasively. However, the PPG waveform contains other significant physiological information that can be used in conjunction to SpO[Formula: see text] for the assessment of oxygenation and blood volumes changes. This paper investigates the use of near infrared spectroscopy (NIRS) processing techniques for extracting relative concentration changes of oxygenated ([Formula: see text]HbO[Formula: see text]), reduced ([Formula: see text]HHb) and total haemoglobin ([Formula: see text]tHb) from dual-wavelength PPG signals during intermittent pressure-increasing vascular occlusions. A reflectance PPG sensor was attached on the left forearm of nineteen (n = 19) volunteers, along with a reference NIRS sensor positioned on the same forearm, above the left brachioradialis. The investigation protocol consisted of seven intermittent and pressure-increasing vascular occlusions. Relative changes in haemoglobin concentrations were obtained by applying the modified Beer-Lambert law to PPG signals, while oxygenation changes were estimated by the difference between red and infrared attenuations of DC PPGs (A[Formula: see text] = [Formula: see text]A[Formula: see text] - [Formula: see text]A[Formula: see text]) and by the conventional SpO[Formula: see text]. The [Formula: see text]HbO[Formula: see text], [Formula: see text]HHb, [Formula: see text]tHb from the PPG signals indicated significant changes in perfusion induced by either partial and complete occlusions (p < 0.05). The trends in the variables extracted from PPG showed good correlation with the same parameters measured by the reference NIRS monitor. Bland and Altman analysis of agreement between PPG and NIRS showed underestimation of the magnitude of changes by the PPG. A[Formula: see text

  6. Reactive oxygen species, oxidative stress, glaucoma and hyperbaric oxygen therapy.

    PubMed

    McMonnies, Charles

    This review examines the role of oxidative stress in damage to cells of the trabecular meshwork and associated impaired aqueous drainage as well as damage to retinal ganglion cells and associated visual field losses. Consideration is given to the interaction between vascular and mechanical explanations for pathological changes in glaucoma. For example, elevated intraocular pressure (IOP) forces may contribute to ischaemia but there is increasing evidence that altered blood flow in a wider sense is also involved. Both vascular and mechanical theories are involved through fluctuations in intraocular pressure and dysregulation of blood flow. Retinal function is very sensitive to changes in haemoglobin oxygen concentration and the associated variations in the production of reactive oxygen species. Reperfusion injury and production of reactive oxygen species occurs when IOP is elevated or blood pressure is low and beyond the capacity for blood flow autoregulation to maintain appropriate oxygen concentration. Activities such as those associated with postural changes, muscular effort, eye wiping and rubbing which cause IOP fluctuation, may have significant vascular, mechanical, reperfusion and oxidative stress consequences. Hyperbaric oxygen therapy exposes the eye to increased oxygen concentration and the risk of oxidative damage in susceptible individuals. However, oxygen concentration in aqueous humour, and the risk of damage to trabecular meshwork cells may be greater if hyperbaric oxygen is delivered by a hood which exposes the anterior ocular surface to higher than normal oxygen levels. Oronasal mask delivery of hyperbaric oxygen therapy appears to be indicated in these cases. Copyright © 2017 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  7. Haemoglobin modulates NO emission and hyponasty under hypoxia-related stress in Arabidopsis thaliana.

    PubMed

    Hebelstrup, Kim H; van Zanten, Martijn; Mandon, Julien; Voesenek, Laurentius A C J; Harren, Frans J M; Cristescu, Simona M; Møller, Ian M; Mur, Luis A J

    2012-09-01

    Nitric oxide (NO) and ethylene are signalling molecules that are synthesized in response to oxygen depletion. Non-symbiotic plant haemoglobins (Hbs) have been demonstrated to act in roots under oxygen depletion to scavenge NO. Using Arabidopsis thaliana plants, the online emission of NO or ethylene was directly quantified under normoxia, hypoxia (0.1-1.0% O(2)), or full anoxia. The production of both gases was increased with reduced expression of either of the Hb genes GLB1 or GLB2, whereas NO emission decreased in plants overexpressing these genes. NO emission in plants with reduced Hb gene expression represented a major loss of nitrogen equivalent to 0.2mM nitrate per 24h under hypoxic conditions. Hb gene expression was greatly enhanced in flooded roots, suggesting induction by reduced oxygen diffusion. The function could be to limit loss of nitrogen under NO emission. NO reacts with thiols to form S-nitrosylated compounds, and it is demonstrated that hypoxia substantially increased the content of S-nitrosylated compounds. A parallel up-regulation of Hb gene expression in the normoxic shoots of the flooded plants may reflect signal transmission from root to shoot via ethylene and a role for Hb in the shoots. Hb gene expression was correlated with ethylene-induced upward leaf movement (hyponastic growth) but not with hypocotyl growth, which was Hb independent. Taken together the data suggest that Hb can influence flood-induced hyponasty via ethylene-dependent and, possibly, ethylene-independent pathways.

  8. Low-grade inflammation is associated with lower haemoglobin levels in healthy individuals: results from the Danish blood donor study.

    PubMed

    Kotzé, S R; Pedersen, O B; Petersen, M S; Sørensen, E; Thørner, L W; Sørensen, C J; Rigas, A S; Hjalgrim, H; Rostgaard, K; Ullum, H; Erikstrup, C

    2016-08-01

    Chronic inflammation can lead to anaemia of chronic disease due to the sequestration of iron caused by inflammatory cytokines and the protein hepcidin. However, the effect of low-grade inflammation (LGI) on haemoglobin among healthy individuals is not known. This study examines the effect of LGI on haemoglobin among Danish blood donors. We performed multivariable linear regression to assess the effect of LGI (i.e. high-sensitivity C-reactive protein above 3 mg/l but below 10 mg/l) on haemoglobin in 17 322 Danish blood donors. We also performed multivariable logistic regression to evaluate the effect of LGI on the risk of having low haemoglobin (below the 10th percentile among men and women, respectively). We adjusted for donation activity, age, sex, low ferritin, oral contraceptives and menopause. All analyses were stratified by current smoking status. LGI was associated with lower haemoglobin (0·08 mm lower [0·12 g/dl], 95% confidence interval (CI): -0·11-0·05) and increased risk of low haemoglobin (OR = 1·22, 95% CI: 1·05-1·43) in non-smokers. Conversely, LGI was associated with higher haemoglobin in smokers (0·12 mm [0·19 g/dl], 95% CI: 0·06-0·18). In this first study of LGI and haemoglobin in healthy individuals, there was a negative association between LGI and haemoglobin in non-smokers. The association was positive in smokers, probably because smoking leads to both increased inflammation and increased haemoglobin through CO exposure. © 2016 International Society of Blood Transfusion.

  9. Evaluation of the validity of a rapid method for measuring high and low haemoglobin levels in whole blood donors.

    PubMed

    Shahshahani, Hayedeh J; Meraat, Nahid; Mansouri, Fatemeh

    2013-07-01

    Haemoglobin screening methods need to be highly sensitive to detect both low and high haemoglobin levels and avoid unnecessary rejection of potential blood donors. The aim of this study was to evaluate the accuracy of measurements by HemoCue in blood donors. Three hundred and fourteen randomly selected, prospective blood donors were studied. Single fingerstick blood samples were obtained to determine the donors' haemoglobin levels by HemoCue, while venous blood samples were drawn for measurement of the haemoglobin level by both HemoCue and an automated haematology analyser as the reference method. The sensitivity, specificity, predictive values and correlation between the reference method and HemoCue were assessed. Cases with a haemoglobin concentration in the range of 12.5-17.9 g/dL were accepted for blood donation. Analysis of paired results showed that haemoglobin levels measured by HemoCue were higher than those measured by the reference method. There was a significant correlation between the reference method and HemoCue for haemoglobin levels less than 12.5 g/dL. The correlation was less strong for increasing haemoglobin levels. Linear correlation was poor for haemoglobin levels over 18 g/dL. Thirteen percent of donors, who had haemoglobin levels close to the upper limit, were unnecessarily rejected. HemoCue is suitable for screening for anaemia in blood donors. Most donors at Yazd are males and a significant percentage of them have haemoglobin values close to the upper limit for acceptance as a blood donor; since these subjects could be unnecessarily rejected on the basis of HemoCue results and testing with this method is expensive, it is recommended that qualitative methods are used for primary screening and accurate quantitative methods used in clinically suspicious cases or when qualitative methods fail.

  10. Assessment of tissue oxygenation of periodontal inflammation in smokers using optical spectroscopy.

    PubMed

    Liu, Kan-Zhi; Duarte, Poliana Mendes; Santos, Vanessa Renata; Xiang, Xiaoming; Xu, Minqi; Miranda, Tamires Szeremeske; Fermiano, Daiane; Gonçalves, Tiago Eduardo Dias; Sowa, Micheal G

    2014-04-01

    We have recently developed a periodontal diagnostic tool that was validated in non-smokers with periodontitis. Tobacco smoking is a recognized risk factor for periodontal diseases that can mask gingival bleeding and lead to a false negative diagnosis. Therefore, the purpose of current study is to further validate this instrument in smokers with periodontal diseases. Using a portable optical near-infrared spectrometer, optical spectra were obtained, processed and evaluated from healthy (n = 108), gingivitis (n = 100), and periodontitis (n = 79) sites of 54 systemically healthy smokers. A modified Beer-Lambert unmixing model that incorporates a non-parametric scattering loss function was used to determine the relative contribution of deoxygenated haemoglobin (Hb) and oxygenated haemoglobin (HbO2 ) to the overall spectrum. The balance between tissue oxygen delivery and utilization in periodontal tissues was then assessed. Tissue oxygen saturation was significantly decreased in the gingivitis (p = 0.016) and periodontitis (p = 0.007) sites, compared to the healthy sites. There was a trend towards increased concentration of Hb and decreased concentration of HbO2 from healthy to diseased sites, without statistical significance (p > 0.05). Optical spectroscopy can determine tissue oxygenation profiles of healthy and diseased sites in smokers. The spectral profile of periodontal sites in smokers generally resembles those from non-smoking patients. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Effects of nitrite exposure on functional haemoglobin levels, bimodal respiration, and swimming performance in the facultative air-breathing fish Pangasianodon hypophthalmus.

    PubMed

    Lefevre, Sjannie; Jensen, Frank B; Huong, Do T T; Wang, Tobias; Phuong, Nguyen T; Bayley, Mark

    2011-07-01

    In this study we investigated nitrite (NO₂⁻) effects in striped catfish, a facultative air-breather. Fish were exposed to 0, 0.4, and 0.9 mM nitrite for 0, 1, 2, 4, and 7 days, and levels of functional haemoglobin, methaemoglobin (metHb) and nitrosyl haemoglobin (HbNO) were assessed using spectral deconvolution. Plasma concentrations of nitrite, nitrate, chloride, potassium, and sodium were also measured. Partitioning of oxygen consumption was determined to reveal whether elevated metHb (causing functional hypoxia) induced air-breathing. The effects of nitrite on maximum oxygen uptake (MO(2max)) and critical swimming speed (U(crit)) were also assessed. Striped catfish was highly tolerant to nitrite exposure, as reflected by a 96 h LC₅₀ of 1.65 mM and a moderate nitrite uptake into the blood. Plasma levels of nitrite reached a maximum after 1 day of exposure, and then decreased, never exceeding ambient levels. MetHb, HbNO and nitrate (a nitrite detoxification product) also peaked after 1 day and then decreased. Only high levels of nitrite and metHb caused reductions in MO(2max) and U(crit). The response of striped catfish contrasts with that seen in most other fish species and discloses efficient mechanisms of combating nitrite threats. Furthermore, even though striped catfish is an efficient air-breather, this species has the ability to sustain aerobic scope and swimming performance without air-breathing, even when faced with nitrite-induced reductions in blood oxygen carrying capacity. Our study is the first to confirm that high levels of nitrite and metHb reduce MO(2max) and thereby aerobic scope, while more moderate elevations fail to do so. Further studies are needed to elucidate the mechanisms underlying the low nitrite accumulation in striped catfish. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Benefits of 21% Oxygen Compared with 100% Oxygen for Delivery of Isoflurane to Mice (Mus musculus) and Rats (Rattus norvegicus)

    PubMed Central

    Wilding, Laura A; Hampel, Joe A; Khoury, Basma M; Kang, Stacey; Machado‑Aranda, David; Raghavendran, Krishnan; Nemzek, Jean A

    2017-01-01

    At research institutions, isoflurane delivered by precision vaporizer to a face mask is the standard for rodent surgery and for procedures with durations that exceed a few minutes. Pure oxygen is often used as the carrier gas for isoflurane anesthesia, despite documented complications from long-term 100% oxygen use in humans and known occupational safety risks. We therefore examined the effect of anesthetic delivery gas on physiologic variables in mice and rats. Rodents were anesthetized for 60 min with isoflurane delivered in either 21% or 100% oxygen by means of a nose cone. We noted no difference between carrier gasses in physiologic variables in mice, including body temperature, respiratory rate, mean arterial pressure, surgical recovery time, pH, or PaCO2.However, blood gas analysis revealed evidence of a ventilation–perfusion mismatch in the 100% oxygen group. Pressure–volume hysteresis and histomorphometric analyses confirmed the presence of increased atelectasis in mice that received 100% oxygen. Unlike mice, rats that received isoflurane in 100% oxygen had acute respiratory acidosis and elevated mean arterial pressure, but atelectasis was similar between carrier gasses. Our data suggest that both 100% and 21% oxygen are acceptable for the delivery of isoflurane to mice. However, mice anesthetized for studies focused on lung physiology or architecture would benefit from the delivery of isoflurane in 21% oxygen to reduce absorption atelectasis and the potential associated downstream inflammatory effects. For rats, delivery of isoflurane in 21% and 100% oxygen both caused perturbations in physiologic variables, and choosing a carrier gas is not straightforward. PMID:28315643

  13. Method and apparatus for producing oxygen and nitrogen and membrane therefor

    DOEpatents

    Roman, I.C.; Baker, R.W.

    1985-09-17

    Process and apparatus for the separation and purification of oxygen and nitrogen as well as a novel membrane useful therein are disclosed. The process utilizes novel facilitated transport membranes to selectively transport oxygen from one gaseous stream to another, leaving nitrogen as a byproduct. In the method, an oxygen carrier capable of reversibly binding molecular oxygen is dissolved in a polar organic membrane which separates a gaseous feed stream such as atmospheric air and a gaseous product stream. The feed stream is maintained at a sufficiently high oxygen pressure to keep the oxygen carrier in its oxygenated form at the interface of the feed stream with the membrane, while the product stream is maintained at a sufficiently low oxygen pressure to keep the carrier in its deoxygenated form at the interface of the product stream with the membrane. In an alternate mode of operation, the feed stream is maintained at a sufficiently low temperature and high oxygen pressure to keep the oxygen carrier in its oxygenated form at the interface of the feed stream with the membrane and the product stream is maintained at a sufficiently high temperature to keep the carrier in its deoxygenated form at the interface of the product stream with the membrane. Under such conditions, the carrier acts as a shuttle, picking up oxygen at the feed side of the membrane, diffusing across the membrane as the oxygenated complex, releasing oxygen to the product stream, and then diffusing back to the feed side to repeat the process. Exceptionally and unexpectedly high O[sub 2]/N[sub 2] selectivity, on the order of 10 to 30, is obtained, as well as exceptionally high oxygen permeability, on the order of 6 to 15 [times] 10[sup [minus]8] cm[sup 3]-cm/cm[sup 2]-sec-cmHg, as well as a long membrane life of in excess of 3 months, making the process commercially feasible. 2 figs.

  14. Method and apparatus for producing oxygen and nitrogen and membrane therefor

    DOEpatents

    Roman, Ian C.; Baker, Richard W.

    1985-01-01

    Process and apparatus for the separation and purification of oxygen and nitrogen as well as a novel membrane useful therein are disclosed. The process utilizes novel facilitated transport membranes to selectively transport oxygen from one gaseous stream to another, leaving nitrogen as a byproduct. In the method, an oxygen carrier capable of reversibly binding molecular oxygen is dissolved in a polar organic membrane which separates a gaseous feed stream such as atmospheric air and a gaseous product stream. The feed stream is maintained at a sufficiently high oxygen pressure to keep the oxygen carrier in its oxygenated form at the interface of the feed stream with the membrane, while the product stream is maintained at a sufficiently low oxygen pressure to keep the carrier in its deoxygenated form at the interface of the product stream with the membrane. In an alternate mode of operation, the feed stream is maintained at a sufficiently low temperature and high oxygen pressure to keep the oxygen carrier in its oxygenated form at the interface of the feed stream with the membrane and the product stream is maintained at a sufficiently high temperature to keep the carrier in its deoxygenated form at the interface of the product stream with the membrane. Under such conditions, the carrier acts as a shuttle, picking up oxygen at the feed side of the membrane, diffusing across the membrane as the oxygenated complex, releasing oxygen to the product stream, and then diffusing back to the feed side to repeat the process. Exceptionally and unexpectedly high O.sub.2 /N.sub.2 selectivity, on the order of 10 to 30, is obtained, as well as exceptionally high oxygen permeability, on the order of 6 to 15.times.10.sup.-8 cm.sup.3 -cm/cm.sup.2 -sec-cmHg, as well as a long membrane life of in excess of 3 months, making the process commercially feasible.

  15. Continuous monitoring of haemoglobin concentration after in-vivo adjustment in patients undergoing surgery with blood loss.

    PubMed

    Frasca, D; Mounios, H; Giraud, B; Boisson, M; Debaene, B; Mimoz, O

    2015-07-01

    Non-invasive monitoring of haemoglobin concentration provides real-time measurement of haemoglobin concentration (SpHb) using multi-wavelength pulse co-oximetry. We hypothesised that in-vivo adjustment using the mean of three haemoglobinometer (HemoCue®) measurements from an arterial blood sample at the first SpHb measurement (HCueART) would increase the accuracy of the monitor. The study included 41 adults for a total of 173 measurements of haemoglobin concentration. In-vivo adjusted SpHb was automatically calculated by the following formula: in-vivo adjusted SpHb = unadjusted SpHb - (SpHb - HCueART). The accuracy of in-vivo adjusted SpHb was compared with SpHb retrospectively adjusted using the same formula, except for haemoglobin level which was assessed at the central laboratory and then compared with all other available invasive methods of haemoglobin measurement (co-oximetry, HbSAT; arterial HemoCue, HCueART; capillary HemoCue, HCueCAP). Compared with laboratory measurement of haemoglobin concentration, bias (precision) for unadjusted SpHb, in-vivo adjusted SpHb, retrospectively adjusted SpHb, HbSAT, HCueART and HCueCAP were -0.4 (1.4), -0.3 (1.1), -0.3 (1.1), -0.6 (0.7), 0.0 (0.4) and -0.5 (1.2) g.dl(-1) , respectively. In-vivo adjustment of SpHb values using the mean of three arterial HemoCue measurements improved the accuracy of the device similar to those observed after a retrospective adjustment using central laboratory haemoglobin level. © 2015 The Association of Anaesthetists of Great Britain and Ireland.

  16. Common antigenic determinants of haemoglobin as basis of immunological cross-reactivity between chironomid species (Diptera, Chironomidae): studies with human and animal sera.

    PubMed Central

    Baur, X; Dewair, M; Haegele, K; Prelicz, H; Scholl, A; Tichy, H

    1983-01-01

    Chironomids, of which approximately 10,000 species exist, are reported to cause severe immediate type allergic diseases in man. In the present study, immunological cross-reactivity between 14 chironomid species from different continents was proven by RAST inhibition, double immunodiffusion and a new allergoprint technique, based upon PAGE separation of insect crude extracts. Using isolated chironomid haemoglobins and sera of sensitized persons, as well as rabbit antibodies against larval crude extract or against the haemoglobin fraction of Chironomus thummi, it could be proven that cross-reactivity derives at least predominantly from haemoglobin components with common antigenic determinants in the different species. Images Fig. 2 Fig. 7 Fig. 8 Fig. 9 PMID:6197219

  17. Inherited haemoglobin disorders: an increasing global health problem.

    PubMed Central

    Weatherall, D. J.; Clegg, J. B.

    2001-01-01

    Despite major advances in our understanding of the molecular pathology, pathophysiology, and control and management of the inherited disorders of haemoglobin, thousands of infants and children with these diseases are dying through lack of appropriate medical care. This problem will undoubtedly increase over the next 20 years because, as the result of a reduction in childhood mortality due to infection and malnutrition, more babies with haemoglobin disorders will survive to present for treatment. Although WHO and various voluntary agencies have tried to disseminate information about these diseases, they are rarely mentioned as being sufficiently important to be included in setting health care priorities for the future. It takes considerable time to establish expertise in developing programmes for the control and management of these conditions, and the lessons learned in developed countries will need to be transmitted to those countries in which they occur at a high frequency. PMID:11545326

  18. Limitations of high dose carrier based formulations.

    PubMed

    Yeung, Stewart; Traini, Daniela; Tweedie, Alan; Lewis, David; Church, Tanya; Young, Paul M

    2018-06-10

    This study was performed to investigate how increasing the active pharmaceutical ingredient (API) content within a formulation affects the dispersion of particles and the aerosol performance efficiency of a carrier based dry powder inhalable (DPI) formulation, using a custom dry powder inhaler (DPI) development rig. Five formulations with varying concentrations of API beclomethasone dipropionate (BDP) between 1% and 30% (w/w) were formulated as a multi-component carrier system containing coarse lactose and fine lactose with magnesium stearate. The morphology of the formulation and each component were investigated using scanning electron micrographs while the particle size was measured by laser diffraction. The aerosol performance, in terms of aerodynamic diameter, was assessed using the British pharmacopeia Apparatus E cascade impactor (Next generation impactor). Chemical analysis of the API was observed by high performance liquid chromatography (HPLC). Increasing the concentration of BDP in the blend resulted in increasing numbers and size of individual agglomerates and densely packed BDP multi-layers on the surface of the lactose carrier. BDP present within the multi-layer did not disperse as individual primary particles but as dense agglomerates, which led to a decrease in aerosol performance and increased percentage of BDP deposition within the Apparatus E induction port and pre-separator. As the BDP concentration in the blends increases, aerosol performance of the formulation decreases, in an inversely proportional manner. Concurrently, the percentage of API deposition in the induction port and pre-separator could also be linked to the amount of micronized particles (BDP and Micronized composite carrier) present in the formulation. The effect of such dose increase on the behaviour of aerosol dispersion was investigated to gain greater insight in the development and optimisation of higher dosed carrier-based formulations. Copyright © 2018 Elsevier B.V. All

  19. Significance of myoglobin as an oxygen store and oxygen transporter in the intermittently perfused human heart: a model study.

    PubMed

    Endeward, Volker; Gros, Gerolf; Jürgens, Klaus D

    2010-07-01

    The mechanisms by which the left ventricular wall escapes anoxia during the systolic phase of low blood perfusion are investigated, especially the role of myoglobin (Mb), which can (i) store oxygen and (ii) facilitate intracellular oxygen transport. The quantitative role of these two Mb functions is studied in the maximally working human heart. Because discrimination between Mb functions has not been achieved experimentally, we use a Krogh cylinder model here. At a heart rate of 200 beats/min and a 1:1 ratio of diastole/systole, the systole lasts for 150 ms. The basic model assumption is that, with mobile Mb, the oxygen stored in the end-diastolic left ventricle wall exactly meets the demand during the 150 ms of systolic cessation of blood flow. The coronary blood flow necessary to achieve this agrees with literature data. By considering Mb immobile or setting its concentration to zero, respectively, we find that, depending on Mb concentration, Mb-facilitated O(2) transport maintains O(2) supply to the left ventricle wall during 22-34 of the 150 ms, while Mb storage function accounts for a further 12-17 ms. When Mb is completely absent, anoxia begins to develop after 116-99 ms. While Mb plays no significant role during diastole, it supplies O(2) to the left ventricular wall for < or = 50 ms of the 150 ms systole, whereas capillary haemoglobin is responsible for approximately 80 ms. Slight increases in haemoglobin concentration, blood flow, or capillary density can compensate the absence of Mb, a finding which agrees well with the observations using Mb knockout mice.

  20. Pre-treatment haemoglobin and peripheral blood lymphocyte count as independent predictors of outcome in carcinoma of cervix.

    PubMed

    Hoskin, P J; Rojas, A M; Peiris, S N; Mullassery, V; Chong, I Y

    2014-04-01

    To evaluate pre-treatment haemoglobin and peripheral blood lymphocyte (PBL) counts as predictors of treatment outcome in cervix carcinoma treated with radical chemoradiation. Pre-treatment PBL counts and haemoglobin concentrations were retrieved from full blood count examinations from 111 patients who received concurrent chemoradiotherapy. Overall survival and relapse-free survival were obtained using the Kaplan-Meier method by ranking the data by median haemoglobin and PBL, singly and then in association. Their independence and significance as predictors of outcome were analysed using the Cox proportional hazard model. Survival rates were significantly higher in patients whose haemoglobin level or PBL counts were at or above the corresponding median value. At 5 years, rates of overall survival were 77% versus 41% (P = 0.0003) and 75% versus 42% (P = 0.002), when dichotomised around median haemoglobin and PBL, respectively. In multivariate and univariate analyses, both PBL and haemoglobin were independent and significant predictors for risk of death and relapse. Their predictive power was dramatically enhanced when the data were stratified into four groups by associating patients with haemoglobin ≥ median or < median with those whose PBL was ≥ or < median. Baseline PBL and haemoglobin seem to be strong, independent predictors of treatment outcome in carcinoma of the cervix, particularly if patient response is ranked using the predictors simultaneously. The hypothesis needs to be tested and, if confirmed, the markers should be used in combination to identify those at greater risk of failure who may benefit from additional therapy, with further validation in prospective trials offering treatment modification. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  1. Oxygen Gradients in the Microcirculation

    PubMed Central

    Pittman, Roland N.

    2010-01-01

    Early in the last century August Krogh embarked on a series of seminal studies to understand the connection between tissue metabolism and mechanisms by which the cardiovascular system supplied oxygen to meet those needs. Krogh recognized that oxygen was supplied from blood to the tissues by passive diffusion and that the most likely site for oxygen exchange was the capillary network. Studies of tissue oxygen consumption and diffusion coefficient, coupled with anatomical studies of capillarity in various tissues, led him to formulate a model of oxygen diffusion from a single capillary. Fifty years after the publication of this work, new methods were developed which allowed the direct measurement of oxygen in and around microvessels. These direct measurements have confirmed the predictions by Krogh and have led to extensions of his ideas resulting in our current understanding of oxygenation within the microcirculation. Developments during the last 40 years are reviewed, including studies of oxygen gradients in arterioles, capillaries, venules, microvessel wall and surrounding tissue. These measurements were made possible by the development and use of new methods to investigate oxygen in the microcirculation, so mention is made of oxygen microelectrodes, microspectrophotometry of haemoglobin and phosphorescence quenching microscopy. Our understanding of oxygen transport from the perspective of the microcirculation has gone from a consideration of oxygen gradients in capillaries and tissue to the realization that oxygen has the ability to diffuse from any microvessel to another location under the conditions that there exists a large enough PO2 gradient and that the permeability for oxygen along the intervening pathway is sufficient. PMID:21281453

  2. Attrition Rate of Oxygen Carriers in Chemical Looping Combustion Systems

    NASA Astrophysics Data System (ADS)

    Feilen, Harry Martin

    This project developed an evaluation methodology for determining, accurately and rapidly, the attrition resistance of oxygen carrier materials used in chemical looping technologies. Existing test protocols, to evaluate attrition resistance of granular materials, are conducted under non-reactive and ambient temperature conditions. They do not accurately reflect the actual behavior under the unique process conditions of chemical looping, including high temperatures and cyclic operation between oxidizing and reducing atmospheres. This project developed a test method and equipment that represented a significant improvement over existing protocols. Experimental results obtained from this project have shown that hematite exhibits different modes of attrition, including both due to mechanical stresses and due to structural changes in the particles due to chemical reaction at high temperature. The test methodology has also proven effective in providing reactivity changes of the material with continued use, a property, which in addition to attrition, determines material life. Consumption/replacement cost due to attrition or loss of reactivity is a critical factor in the economic application of the chemical looping technology. This test method will allow rapid evaluation of a wide range of materials that are best suited for this technology. The most important anticipated public benefit of this project is the acceleration of the development of chemical looping technology for lowering greenhouse gas emissions from fossil fuel combustion.

  3. Cross-sectional relationship between haemoglobin concentration and measures of physical and cognitive function in an older rural South African population.

    PubMed

    Payne, Collin F; Davies, Justine I; Gomez-Olive, F Xavier; Hands, Katherine J; Kahn, Kathleen; Kobayashi, Lindsay C; Tipping, Brent; Tollman, Stephen M; Wade, Alisha; Witham, Miles D

    2018-04-21

    Age cohort differences in haemoglobin concentrations and associations with physical and cognitive performance among populations of lower income and middle-income countries have not previously been described. We examined the association between these factors among older men and women in rural South Africa. We analysed cross-sectional data from a population-based study of rural South African men and women aged 40 and over (n=4499), with data drawn from questionnaire responses, a cognitive battery, objective physical function tests and blood tests. Anaemia was defined as a haemoglobin concentration <12 g/dL for women and <13 g/dL for men. We related haemoglobin concentrations to each of age, grip strength, walk speed and a latent cognitive function z-score for men and women separately. We used unadjusted correlations and linear models to adjust for comorbidities and inflammation. In total, 1042 (43.0%) women and 833 (40.1%) men were anaemic. Haemoglobin concentrations were inversely correlated with age for men but not for women; in adjusted analyses, haemoglobin was 0.3 g/dL lower per decade older for men (95% CI 0.2 to 0.4 g/dL). In adjusted analyses, haemoglobin concentration was independently associated with grip strength in women (B=0.391, 95% CI 0.177 to 0.605), but this did not reach significance in men (B=0.266, 95% CI -0.019 to 0.552); no associations were observed between haemoglobin levels and walk speed or cognitive score. Anaemia was prevalent in this study population of middle-aged and older, rural South African adults, but in contrast to high-income countries, it was not associated with poor physical or cognitive function. Our findings need to be replicated in other populations. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Racial variations in booking haemoglobin of primigravidae in Malaysia: a prospective study

    PubMed Central

    2013-01-01

    Background Variations in racial haemoglobin had been previously described in multiple studies locally and abroad. This study was conducted to quantify the differences in haemoglobin of booking primigravidae amongst the three major races in Malaysia at the antenatal clinic of University Malaya Medical Centre, Kuala Lumpur. Findings One year prospective study of booking full blood count sample of primigravidae taken in one centre was conducted. Multiple comparative analyses of the booking haemoglobin were performed using the One-way ANOVA comparative mean test in each trimester. 622 primigravidae without any known history of haematological disorders were recruited into the study. The mean haemoglobin for the Indian race was the lowest compared to the two other races in the second and the third trimesters, and it was found to be statistically significant lower (p- value 0.001) than the Malay race in the second trimester. It was also found that the Indian race had a significantly higher incidence of moderate to severe anaemia (p- value: 0.029). The prevalence of anaemia in our study population is also significantly higher in the Indian population (p- value: 0.01). Conclusions The findings from this study have established that there is racial preponderance to anaemia in pregnancy. The Indian race is at a higher risk of having anaemia in pregnancy particularly in the second trimester. PMID:23634656

  5. Phyto-mediated nanostructured carriers based on dual vegetable actives involved in the prevention of cellular damage.

    PubMed

    Istrati, D; Lacatusu, I; Bordei, N; Badea, G; Oprea, O; Stefan, L M; Stan, R; Badea, N; Meghea, A

    2016-07-01

    The growing scientific interest in exploitation of vegetable bioactives has raised a number of questions regarding their imminent presence in pharmaceutical formulations. This study intends to demonstrate that a dual combination between vegetable oil (e.g. thistle oil, safflower oil, sea buckthorn oil) and a carrot extract represents an optimal approach to formulate safe carrier systems that manifest cell regeneration effect and promising antioxidant and anti-inflammatory activity. Inclusion of both natural actives into lipid carriers imparted a strong negative charge on the nanocarrier surface (up to -45mV) and displayed average sizes of 70nm to 140nm. The entrapment efficiency of carrot extract into nanostructured carriers ranged between 78.3 and 88.3%. The in vitro release study has demonstrated that the entrapment of the extract represents a viable way for an equilibrated release of carotenoids. Besides the excellent antioxidant properties (e.g. scavenging up to 98% of the free oxygen radicals), the results of cellular integrity (e.g. cell viability of 133%) recommend these nanocarriers based on dual carrot extract-bioactive oil as a promising trend for the treatment of certain disorders in which oxidative stress plays a prominent role. In addition, the lipid nanocarriers based on safflower oil and sea buckthorn oil demonstrated an anti-inflammatory effect on LPS induced THP-1 macrophages, by inhibiting the secretion of two pro-inflammatory cytokines, IL-6 and TNF-α. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Implementing oxygen control in chip-based cell and tissue culture systems.

    PubMed

    Oomen, Pieter E; Skolimowski, Maciej D; Verpoorte, Elisabeth

    2016-09-21

    Oxygen is essential in the energy metabolism of cells, as well as being an important regulatory parameter influencing cell differentiation and function. Interest in precise oxygen control for in vitro cultures of tissues and cells continues to grow, especially with the emergence of the organ-on-a-chip and the desire to emulate in vivo conditions. This was recently discussed in this journal in a Critical Review by Brennan et al. (Lab Chip (2014). DOI: ). Microfluidics can be used to introduce flow to facilitate nutrient supply to and waste removal from in vitro culture systems. Well-defined oxygen gradients can also be established. However, cells can quickly alter the oxygen balance in their vicinity. In this Tutorial Review, we expand on the Brennan paper to focus on the implementation of oxygen analysis in these systems to achieve continuous monitoring. Both electrochemical and optical approaches for the integration of oxygen monitoring in microfluidic tissue and cell culture systems will be discussed. Differences in oxygen requirements from one organ to the next are a challenging problem, as oxygen delivery is limited by its uptake into medium. Hence, we discuss the factors determining oxygen concentrations in solutions and consider the possible use of artificial oxygen carriers to increase dissolved oxygen concentrations. The selection of device material for applications requiring precise oxygen control is discussed in detail, focusing on oxygen permeability. Lastly, a variety of devices is presented, showing the diversity of approaches that can be employed to control and monitor oxygen concentrations in in vitro experiments.

  7. An evaluation of the HemoCue for measuring haemoglobin in field studies in Jamaica.

    PubMed Central

    Hudson-Thomas, M.; Bingham, K. C.; Simmons, W. K.

    1994-01-01

    The HemoCue system utilizes the principle of oxidation of haemoglobin to hemiglobin by sodium nitrite and the subsequent conversion of hemiglobin to hemiglobinazide by sodium azide. The reagents for these reactions are contained within a small disposable microcuvette of approximately 10 microliters in volume. A venous or capillary sample is introduced into the microcuvette by capillary action and, after reaction with the reagents, the absorbance is read in the HemoCue photometer at 565 and 880 nm. The haemoglobin concentration is then displayed as a digital reading, in either g/dl or mmol/l in 15-45 seconds. We compared haemoglobin values obtained by the HemoCue system with those from the Coulter Counter S-Plus IV in 366 pregnant women in urban Jamaica, and found a highly significant correlation (r = 0.78, P < 0.01). However, because of the convenience and ease of use of this instrument and considering the relatively high cost, we recommend it for use only as a research tool in field studies where accurate and rapid haemoglobin determinations are required. PMID:8062400

  8. Structural studies of haemoglobin from pisces species shortfin mako shark (Isurus oxyrinchus) at 1.9 Å resolution.

    PubMed

    Ramesh, Pandian; Sundaresan, S S; Sathya Moorthy, Pon; Balasubramanian, M; Ponnuswamy, M N

    2013-11-01

    Haemoglobin (Hb) is a tetrameric iron-containing protein that carries oxygen from the lungs to tissues and carbon dioxide from tissues back to the lungs. Pisces are the advanced aquatic vertebrates capable of surviving at wide depth ranges. The shortfin mako shark (SMS) is the pelagic, largest, fastest and most sophisticated species of the shark kingdom with well developed eyes. Mostly the pisces species are cold blooded in nature. Distinctly, the SMSs are warm-blooded animals with an advanced circulatory system. SMSs are capable of maintaining elevated muscle temperatures up to 33 K above the ambient water temperatures at a depth of 150-500 m. SMSs have a diverged air-breathing mechanism compared with other vertebrates. The haemoglobin molecule consists of four polypeptide chains, namely two α chains, each with 140 amino acids and two β chains each having 136 amino acids. The SMS Hb was found to crystallize in monoclinic space group P21 using the hanging-drop vapour-diffusion method at room temperature. The crystal packing parameters for the SMS Hb structure contain one whole biological molecule in the asymmetric unit with a solvent content of 47%. The SMS Hb quaternary structural features interface-interface interactions and heme binding sites are discussed with different state Hbs and the results reveal that SMS Hb adopts an unliganded deoxy T state conformation.

  9. Carrier lifetimes in polar InGaN-based LEDs

    NASA Astrophysics Data System (ADS)

    Wang, Lai; Jin, Jie; Hao, Zhibiao; Luo, Yi

    2018-02-01

    Measurement of carrier lifetime is very important to understand the physics in light-emitting diodes (LEDs), as it builds a link between carrier concentration and excitation power or current density. In this paper, we present our study on optical and electrical characterizations on carrier lifetimes in polar InGaN-based LEDs. First, a carrier rate equation model is proposed to explain the non-exponential nature of time-resolved photoluminescence (TRPL) decay curves, wherein exciton recombination is replaced by bimolecular recombination, considering the influence of polarization field on electron-hole pairs. Then, nonradiative recombination and radiative recombination coefficients can be deduced from fitting and used to calculate the radiative recombination efficiency. By comparing with the temperature-dependent photoluminescence (TDPL) and power-dependent photoluminescence (PDPL), it is found these three methods provide the consistent results. Second, differential carrier lifetimes depending on injection current are measured in commercial near-ultraviolet (NUV), blue and green LEDs. It is found that carrier lifetime is longer in green one and shorter in NUV one, which is attributed to the influence of polarization-induced quantum confined Stark effect (QCSE). This result implies the carrier density is higher in green LED while lower NUV LED, even the injection current is the same. By ignoring Auger recombination and fitting the efficiency-current and carrier lifetime-current curves simultaneously, the dependence of injection efficiency on carrier concentration in different LED samples are plotted. The NUV LED, which has the shallowest InGaN quantum well, actually exhibits the most serious efficiency droop versus carrier concentration. Then, the approaches to overcome the efficiency droop are discussed.

  10. Controlled and extended drug release behavior of chitosan-based nanoparticle carrier.

    PubMed

    Yuan, Q; Shah, J; Hein, S; Misra, R D K

    2010-03-01

    Controlled drug release is presently gaining significant attention. In this regard, we describe here the synthesis (based on the understanding of chemical structure), structural morphology, swelling behavior and drug release response of chitosan intercalated in an expandable layered aluminosilicate. In contrast to pure chitosan, for which there is a continuous increase in drug release with time, the chitosan-aluminosilicate nanocomposite carrier was characterized by controlled and extended release. Drug release from the nanocomposite particle carrier occurred by degradation of the carrier to its individual components or nanostructures with a different composition. In both the layered aluminosilicate-based mineral and chitosan-aluminosilicate nanocomposite carriers the positively charged chemotherapeutic drug strongly bound to the negatively charged aluminosilicate and release of the drug was slow. Furthermore, the pattern of drug release from the chitosan-aluminosilicate nanocomposite carrier was affected by pH and the chitosan/aluminosilicate ratio. The study points to the potential application of this hybrid nanocomposite carrier in biomedical applications, including tissue engineering and controlled drug delivery. Copyright 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  11. Oxygen gradients in the microcirculation.

    PubMed

    Pittman, R N

    2011-07-01

    Early in the last century August Krogh embarked on a series of seminal studies to understand the connection between tissue metabolism and mechanisms by which the cardiovascular system supplied oxygen to meet those needs. Krogh recognized that oxygen was supplied from blood to the tissues by passive diffusion and that the most likely site for oxygen exchange was the capillary network. Studies of tissue oxygen consumption and diffusion coefficient, coupled with anatomical studies of capillarity in various tissues, led him to formulate a model of oxygen diffusion from a single capillary. Fifty years after the publication of this work, new methods were developed which allowed the direct measurement of oxygen in and around microvessels. These direct measurements have confirmed the predictions by Krogh and have led to extensions of his ideas resulting in our current understanding of oxygenation within the microcirculation. Developments during the last 40 years are reviewed, including studies of oxygen gradients in arterioles, capillaries, venules, microvessel wall and surrounding tissue. These measurements were made possible by the development and use of new methods to investigate oxygen in the microcirculation, so mention is made of oxygen microelectrodes, microspectrophotometry of haemoglobin and phosphorescence quenching microscopy. Our understanding of oxygen transport from the perspective of the microcirculation has gone from a consideration of oxygen gradients in capillaries and tissue to the realization that oxygen has the ability to diffuse from any microvessel to another location under the conditions that there exists a large enough PO(2) gradient and that the permeability for oxygen along the intervening pathway is sufficient. © 2011 The Author. Acta Physiologica © 2011 Scandinavian Physiological Society.

  12. Knowledge of and attitudes to sickle cell disease and sickle carrier screening among new graduates of Nigerian tertiary educational institutions.

    PubMed

    Adewuyi, J O

    2000-09-01

    Six hundred and ten new graduates of Nigerian tertiary institutions were studied for their knowledge of and attitude to sickle cell disorders. A questionnaire was administered to assess knowledge and attitudes. Then a two-hour educational seminar on the basic genetics, transmission, and implications for the affected individuals and their families, of sickle cell disease (SCD) and carrier states was conducted. Sickle carrier screening was undertaken by cellulose acetate haemoglobin electrophoresis. A sickle carrier frequency of 21.6% was found and the questionnaires revealed severely deficient knowledge of the transmission of SCD among the 20-32 year old graduates. After the seminar there was eagerness among the graduates to know their sickle status. It is concluded that unmarried youths in, or graduating from, higher educational institutions may be a most suitable target for information, carrier detection and genetic counselling in the prevention and control of sickle cell disorders.

  13. Purification, crystallization and preliminary X-ray diffraction studies of parakeet (Psittacula krameri) haemoglobin

    PubMed Central

    Jaimohan, S. M.; Naresh, M. D.; Arumugam, V.; Mandal, A. B.

    2009-01-01

    Birds often show efficient oxygen management in order to meet the special demands of their metabolism. However, the structural studies of avian haemo­globins (Hbs) are inadequate for complete understanding of the mechanism involved. Towards this end, purification, crystallization and preliminary X-ray diffraction studies have been carried out for parakeet Hb. Parakeet Hb was crystallized as the met form in low-salt buffered conditions after extracting haemoglobin from crude blood by microcentrifugation and purifying the sample by column chromatography. Good-quality crystals were grown from 10% PEG 3350 and a crystal diffracted to about 2.8 Å resolution. Preliminary diffraction data showed that the Hb crystal belonged to the monoclinic system (space group C2), with unit-cell parameters a = 110.68, b = 64.27, c = 56.40 Å, β = 109.35°. Matthews volume analysis indicated that the crystals contained a half-tetramer in the asymmetric unit. PMID:19851014

  14. Awareness and distribution of ABO, Rhesus blood groups and haemoglobin phenotypes among medical undergraduates in a Nigerian university.

    PubMed

    Akingbola, T S; Yuguda, S; Akinyemi, O O; Olomu, S

    2016-09-01

    In the past two decades the Nigerian government and religious organisations have put more emphasis on knowing the haemoglobin electrophoresis of school children and intending couples respectively. Knowledge of the distribution of blood groups and haemoglobin electrophoretic patterns among young people is vital for the prevention of haemoglobinopathies in the population and for providing effective blood banking services. Therefore, this study was designed to assess the frequency and awareness of blood group and haemoglobinphenotypes among a new set of fourth year clinical medical and dental students of the University of Ibadan, Nigeria. Data, including socio-demographics, self- reported blood group and haemoglobin phenotypes, were obtained from 155 students using a self-administered questionnaire. The ABO, Rhesus (Rh) blood groups and haemoglobin electrophoresis were determined by the tile (slide) technique and cellulose acetate at alkaline phrespectively. Only 43.9% of the participants knew their blood groups while less than a third (29.7%) knew their haemoglobin phenotypes. knowledge of both their blood groups and haemoglobin phenotypes was documented in as low as 20.6% of the respondents. The frequency of haemoglobin AA, AS, AC and. CC were 78.0%, 16.8%, 3.9% and 1.3% respectively. Similarly, the distribution of blood groups were: 0 RhD positive - 47.8%;0 RhD negative- 1.9%;ARhD positive- 21.9%; A RhD negative - 1.3%; B RhD positive - 23.2%; B RhD negative -1.3% and AB RhD positive - 2.6%. No participant was AB RhD negative. Participants who bad previously donated blood and those who were females were more likely to know their blood groups and haemoglobin phenotypes respectively (p<0.05). Awareness of blood groups and haemoglobin phenotypes among the medical and dental students was poor. Documentation and routine screening for haemoglobinphenotypes as well as blood grouping, accompanied by appropriate counseling should be institutionalised in Nigeriantertiary

  15. Identification of haemoglobin New York by haemoglobin A1c measurement using the Sebia Capillarys 2 Flex Piercing system.

    PubMed

    Chao, Yan; Wan, Zemin; Wu, Xiaobin; Qiu, Feng; Wu, Xinzhong; Wang, Yunxiu; Ke, Peifeng; Xu, Jianhua; Zhuang, Junhua; Huang, Xianzhang

    2017-01-01

    Haemoglobinopathies may interfere with the haemoglobin A 1c (HbA 1c ) measurement, leading to incorrect diagnosis and inappropriate treatment. It is essential that HbA 1c assays are capable of identifying haemoglobinopathies. We report two cases of haemoglobin New York (HbNY) discovered through HbA 1c analysis using capillary electrophoresis (Capillarys 2 Flex Piercing [C2FP], Sebia). We used these samples to evaluate the ability of three other HbA 1c assays to identify this variant: ion-exchange high-performance liquid chromatography (Variant II Turbo [VII-T], Bio-Rad); boronate affinity high-performance liquid chromatography (Ultra 2 , Trinity Biotech) and immunoassay (Cobas c501 Tina-quant Generation 3, Roche Diagnostics). Each method was used for HbA 1c assay of in samples from two cases of heterozygous haemoglobinopathy: β 0 -thalassemia/HbNY (Case 1) and HbA/NY (Case 2). Only the C2FP system detected HbNY (an additional peak appeared between HbA 1c and HbA 0 ). Clinical laboratories should be aware of the limitations of their HbA 1c assay methods especially in geographic areas, where haemoglobinopathy prevalence is high.

  16. Use of topical haemoglobin on sloughy wounds in the community setting.

    PubMed

    Bateman, Sharon Dawn

    2015-09-01

    This evaluation aimed to determine whether the use of a haemoglobin spray solution expedited sloughy wound healing. A descriptive evaluation was undertaken within a community setting exploring 25 patients presenting with sloughy healing and non-healing wounds, and the effects of 8 topically administered haemoglobin treatments over a 4-week period. Standard wound cleansing and dressing management were continued, with no changes to pre-evaluation regimens, and care being provided by the patients themselves or by a carer. Data were collected weekly with regard to primary outcomes of slough reduction, wound surface area reduction, patient ease of use (self-care), and overall product experience. At 4 weeks, all wounds demonstrated positive measured endpoints of slough elimination and continued wound-size reduction. Patients and carers found the product easy to use (self-caring) with an overall positive wound care experience. The administration of a haemoglobin spray solution on patients presenting with sloughy wounds resulted in positive healing outcomes of slough elimination and wound reduction alongside positive self-care and product satisfaction. Continued evaluation is recommended to build upon the evidence of this form of treatment.

  17. BLOOD SUBSTITUTES: EVOLUTION FROM NON-CARRYING TO OXYGEN AND GAS CARRYING FLUIDS

    PubMed Central

    Cabrales, Pedro; Intaglietta, Marcos

    2013-01-01

    The development of oxygen (O2) carrying blood substitutes has evolved from the goal of replicating blood O2 transports properties to that of preserving microvascular and organ function, reducing the inherent or potential toxicity of the material used to carry O2, and treating pathologies initiated by anemia and hypoxia. Furthermore, the emphasis has shifted from blood replacement fluid to “O2 therapeutics” that restore tissue oxygenation to specific tissues regions. This review covers the different alternatives, potential and limitations of hemoglobin based O2 carriers (HBOCs) and perfluorocarbon based O2 carriers (PFCOCs), with emphasis on the physiological conditions disturbed in the situation that they will be used. It describes how concepts learned from plasma expanders without O2 carrying capacity can be applied to maintain O2 delivery and summarizes the microvascular responses due to HBOCs and PFCOCs. This review also presents alternative applications of HBOCs and PFCOCs namely: 1) How HBOC O2 affinity can be engineered to target O2 delivery to hypoxic tissues; and 2) How the high gas solubility of PFCOCs provides new opportunities for carrying, dissolving and delivering gases with biological activity. It is concluded that current blood substitutes development has amplified their applications horizon by devising therapeutic functions for oxygen carriers requiring limited O2 delivery capacity restoration. Conversely, full, blood-like O2 carrying capacity re-establishment awaits control of O2 carrier toxicity. PMID:23820271

  18. A multiplexed three-dimensional paper-based electrochemical impedance device for simultaneous label-free affinity sensing of total and glycated haemoglobin: The potential of using a specific single-frequency value for analysis.

    PubMed

    Boonyasit, Yuwadee; Chailapakul, Orawon; Laiwattanapaisal, Wanida

    2016-09-14

    A novel three-dimensional paper-based electrochemical impedance device (3D-PEID) is first introduced for measuring multiple diabetes markers. Herein, a simple 3D-PEID composed of a dual screen-printed electrode on wax-patterned paper coupled with a multilayer of magnetic paper was fabricated for label-free electrochemical detection. The results clearly demonstrated in a step-wise manner that the haptoglobin (Hp)-modified and 3-aminophenylboronic acid (APBA)-modified eggshell membranes (ESMs) were highly responsive to a clinically relevant range of total (0.5-20 g dL(-1); r(2) = 0.989) and glycated haemoglobin (HbA1c) (2.3%-14%; r(2) = 0.997) levels with detection limits (S/N = 3) of 0.08 g dL(-1) and 0.21%, respectively. The optimal binding frequencies of total haemoglobin and HbA1c to their specific recognition elements were 5.18 Hz and 9.99 Hz, respectively. The within-run coefficients of variation (CV) were 1.84%, 2.18%, 1.72%, and 2.01%, whereas the run-to-run CVs were 2.11%, 2.41%, 2.08%, and 2.21%, when assaying two levels of haemoglobin and HbA1c, respectively. The CVs for the haemoglobin and HbA1c levels measured on ten independently fabricated paper-based sheets were 1.96% and 2.10%, respectively. These results demonstrated that our proposed system achieved excellent precision for the simultaneous detection of total haemoglobin and HbA1c, with an acceptable reproducibility of fabrication. The long-term stability of the Hp-modified eggshell membrane (ESM) was 98.84% over a shelf-life of 4 weeks, enabling the possibility of storage or long-distance transport to remote regions, particularly in resource-limited settings; however, for the APBA-modified ESM, the stability was 92.35% over a one-week period. Compared with the commercial automated method, the results demonstrated excellent agreement between the techniques (p-value < 0.05), thus permitting the potential application of 3D-PEID for the monitoring of the glycaemic status in diabetic

  19. [Polymer and oligomer based doxorubicin carriers].

    PubMed

    Kik, Krzysztof; Lwow, Felicja; Szmigiero, Leszek

    2007-01-01

    Doxorubicin and other anthracycline derivatives play an important role in the treatment of many malignant diseases. Unfortunately, clinical effectiveness of this class of drugs is limited by cumulative cardiotoxicity which occurs in significant percentage of patients at cumulative dose in the range 450-600 mg/m2. Therefore, several strategies have been developed to reduce cardiotoxicity of doxorubicin and its analogues. One of the possible ways leading to the improvement of anticancer selectivity of doxorubicin is the design of polymer and olygomer carriers which may transport drug molecules more efficiently and more specifically. Synthetic polymers are of increasing interest as therapeutic agents owing to their enhanced pharmacokinetic profiles relative to small molecule drugs. Currently a new class of multifunctional polymers is being prepared that can "mask" biologically active compounds, such as cytotoxic agents, until they reach target sites, but which can then release the agent in situ to effect the therapy. The legitimacy of the development of polymer based doxorubicine carriers is supported by the growing number of clinical reports indicating that the use of hydrophilic polymers or polymer coated liposomes as a platform for delivery of the drug results in better therapeutic effects than the free drug. In this article we present the most promising strategies directed at the development of improved anthracycline drugs formulations based of polymer and olygomer carriers. We review: 1) polyethylenoglycol-coated ("pegylated") liposomal doxorubicin; 2) extracellulary tumor-activated prodrugs which are conjugates of doxorubicin with peptides; 3) doxorubicin coated by higly polymerised glycosoaminoglycans; 4) conjugates of doxorubicin with copolymer of N-(2-hydroxypropyl)methacrylamide.

  20. The practical application of reflectance spectrophotometry for the demonstration of haemoglobin and its degradation in bruises

    PubMed Central

    Hughes, V K; Ellis, P S; Burt, T; Langlois, N E I

    2004-01-01

    Aims: To develop a non-invasive method to demonstrate the presence of haemoglobin and its degradation products in bruises in live human subjects for the purposes of objectively assisting in the determination of the age of a bruise. Methods: The cuvette holder unit of a Cary 100 Bio UV-Visible Spectrophotometer was replaced with the manufacture’s fibre optic cable and optical reflectance probe. The probe was placed on the skin surface. The absorption spectrum from 780 to 380 nm was collected and transformed into the first derivative. Calculation of the first derivative permits absorption attributed to haemoglobin degradation (primarily to bilirubin, but also haemosiderin) to be separated from absorption by haemoglobin. First derivative and colorimetry values, expressed as CIEL*a*b data, were derived from scans of 50 bruises. Results: The fibre optic cable and probe allowed the spectrophotometer to collect reproducible absorption spectra of bruises in the skin of living subjects. A bruise at three days has greater negative first derivative values at 480 and 490 nm than does a fresh bruise, indicating the local degradation of haemoglobin. Correlation between the first derivative and the CIEL*a*b “b” values in a series of bruises indicates that the yellow colour in a bruise is proportional to the amount of local haemoglobin breakdown. Conclusion: The ability to demonstrate the presence of haemoglobin and measure its degradation in bruises in living human subjects by a non-invasive method has not been described previously, and may be of use in the objective ageing of bruises for forensic purposes. PMID:15047735

  1. Relationship between the degree of perineal trauma at vaginal birth and change in haemoglobin concentration.

    PubMed

    Rubio-Álvarez, Ana; Molina-Alarcón, Milagros; Hernández-Martínez, Antonio

    2017-10-01

    Postpartum anaemia is a problem with high prevalence that significantly affects maternal recovery. Among the causal factors is perineal trauma. However, it is still not known what degree of perineal trauma produces a greater reduction of haemoglobin. To assess the relationship between the degree of perineal trauma and change in haemoglobin concentration at vaginal birth. An observational, analytical retrospective cohort study was performed at the Mancha-Centro Hospital (Spain) during the period 2010-2014. Data were collected regarding 3479 women who gave birth vaginally. The main outcome variable was the change in haemoglobin concentration. Multivariate analysis by means of multiple linear regression was performed to control possible confounding factors and to determine the net effect of each degree of perineal trauma on haemoglobin reduction. Of the total sample, 20.1% of women (699) had an intact perineum, 41.6% (1446) experienced some form of perineal trauma, but not episiotomy, and the remaining 38.3% of women (1334) underwent an episiotomy. The average reduction of haemoglobin was 1.46g/dL (Standard Deviation (SD)=1.09g/dL) for women without episiotomy with a second degree tear and 2.07g/dL (SD=1.24g/dL) for women who had an episiotomy and no perineal tear. The greatest reduction occurred among women with episiotomy and a third or fourth degree tear with a decrease of 3.10g/dL (SD=1.32g/dL). Episiotomy is related to greater reduction of haemoglobin concentration in comparison with all degrees of spontaneous perineal trauma. The use of episiotomy should be strictly limited. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  2. Differential sensitivities of pulmonary and coronary arteries to hemoglobin-based oxygen carriers and nitrovasodilators: study in a bovine ex vivo model of vascular strips.

    PubMed

    Fonseca, Vera; Avizinis, Jessica; Moon-Massat, Paula; Freilich, Daniel; Kim, Hae Won; Hai, Chi-Ming

    2010-01-01

    Vasoconstriction is a major adverse effect of first and second generation hemoglobin-based oxygen carriers (HBOCs) that hinders their development as blood substitute. However, intravenous infusion of HBOC-201 (second generation) to patients induces significant pulmonary hypertension without significant coronary vasoconstriction. We compared contractile responses of isolated bovine pulmonary and coronary arterial strips to HBOC-201 and HBOC-205LL.LT.MW600 (third generation), polymerized bovine hemoglobins of different molecular weight, and their attenuation by nitroglycerin, sodium nitroprusside (SNP), and sodium nitrite. Pulmonary arteries developed negligible basal tone, but exhibited HBOC-dependent amplification of phenylephrine-induced contractions. In contrast, coronary arteries developed significant basal tone, and exhibited HBOC-dependent constant force increment to serotonin-induced contractions. Therefore, relative to basal tone, HBOC-induced contractions were greater in pulmonary than coronary arteries. Furthermore, HBOC-205LL.LT.MW600 appeared to be less vasoactive than HBOC-201. Unexpectedly, pulmonary and coronary arteries exhibited differential sensitivities to nitrovasodilators in parallel with their differential sensitivities to HBOC. However, SNP and sodium nitrite induced significant methemoglobin formation from HBOC, whereas nitroglycerin did not. These results suggest that phenotypic differences between pulmonary and coronary vascular smooth muscle cells could explain the differential hypertensive effects of HBOC on pulmonary and coronary circulation in patients. Among the three nitrovasodilators investigated, nitroglycerin appears to be the most promising candidate for attenuating HBOC-induced pulmonary hypertension in older HBOCs.

  3. Benefits and limitations of composites in carrier-based aircraft

    NASA Technical Reports Server (NTRS)

    Mcerlean, Donald P.

    1992-01-01

    There are many unique aspects of Navy air missions that lead to the differentiation between the design and performance of ship and shore-based aircraft. The major aspects are discussed from which essentially all Navy aircraft design requirements derive. (1) Navy aircraft operate from carriers at sea imposes a broad spectrum of physical conditions, constraints, and requirements ranging from the harsh sea environment, the space limitations of a carrier, takeoff and landing requirements as well as for endurance at long distances from the carrier. (2) Because the carrier and its airwing are intended to be capable of responding to a broad range of contingencies, mission flexibility is essential (maximum weapon carriage, rapid reconfiguration, multiple mission capability). (3) The embarked aircraft provides the long range defense of the battle group against air, surface and subsurface launched antiship missiles. (4) The carrier and its aircraft must operate independently and outside of normal supply lines. Taking into account these aspects, the use of composite materials in the design and performance of naval aircraft is outlined, also listing advantages and disadvantages.

  4. Correcting haemoglobin cut-offs to define anaemia in high-altitude pregnant women in Peru reduces adverse perinatal outcomes.

    PubMed

    Gonzales, Gustavo F; Tapia, Vilma; Gasco, Manuel

    2014-07-01

    To determine if correction of cut-offs of haemoglobin levels to define anaemia at high altitudes affects rates of adverse perinatal outcomes. Data were obtained from 161,909 mothers and newborns whose births occurred between 1,000 and 4,500 m above sea level (masl). Anaemia was defined with or without correction of haemoglobin (Hb) for altitude as Hb <11 g/dL. Correction of haemoglobin per altitude was performed according to guidelines from the World Health Organization. Rates of stillbirths and preterm births were also calculated. Stillbirth and preterm rates were significantly reduced in cases of anaemia calculated after correction of haemoglobin for altitude compared to values obtained without Hb correction. At high altitudes (3,000-4,500 masl), after Hb correction, the rate of stillbirths was reduced from 37.7 to 18.3 per 1,000 live births (p < 0.01); similarly, preterm birth rates were reduced from 13.1 to 8.76 % (p < 0.01). The odds ratios for stillbirths and for preterm births were also reduced after haemoglobin correction. At high altitude, correction of maternal haemoglobin should not be performed to assess the risks for preterm birth and stillbirth. In fact, using low altitude Hb cut-off is associated with predicting those at risk.

  5. The impact of sickle cell trait on glycated haemoglobin in diabetes mellitus.

    PubMed

    Bleyer, A J; Vidya, S; Sujata, L; Russell, G B; Akinnifesi, D; Hire, D; Shihabi, Z; Knovich, M A; Daeihagh, P; Calles, J; Freedman, B I

    2010-09-01

    To determine the effect of sickle cell trait on measurement of glycated haemoglobin (HbA(1c)) in African American patients with diabetes mellitus. This is a retrospective study including 885 outpatients who underwent HbA(1c) testing. Medical record review and sickle cell trait determinations based on the HbA(1c) assay were performed in African American participants. The relationship between HbA(1c) and serum glucose measurements was analysed. Data were obtained from 385 AA (109 with SCT, 22 with haemoglobin C trait and 254 without haemoglobinopathy) and 500 European American patients. In a model created through multivariate repeated-effects regression, the relationship between HbA(1c) and simultaneous serum glucose did not differ between African American subjects with and without the sickle cell trait, but differed between African American subjects without the sickle cell trait and European Americans (P = 0.0002). Sickle cell trait does not impact the relationship between HbA(1c) and serum glucose concentration. In addition, it does not appear to account for ethnic difference in this relationship between African Americans and whites.

  6. Kinetics of NO and O2 binding to a maleimide poly(ethylene glycol)-conjugated human haemoglobin

    PubMed Central

    2004-01-01

    The hypertensive effect observed with most cell-free haemoglobins has been proposed to result from NO scavenging. However, a newly developed PEG [poly(ethylene glycol)]-conjugated haemoglobin, MalPEG-Hb [maleimide-activated PEG-conjugated haemoglobin], is non-hypertensive with unique physicochemical properties: high O2 affinity, low co-operativity and large molecular radius. It is therefore of interest to compare the ligand-binding properties of MalPEG-Hb with unmodified cell-free HbA (stroma-free human haemoglobin). NO association rates for deoxy and oxyMalPEG-Hb and HbA were found to be identical. These results confirm the lack of correlation between hypertension and NO for a similar modified haemoglobin with high molecular radius and low p50 (pO2 at which haemoglobin is half-saturated with O2) [Rohlfs, Bruner, Chiu, Gonzales, Gonzales, Magde, Magde, Vandegriff and Winslow (1998) J. Biol. Chem. 273, 12128–12134]. The R-state O2 association kinetic constants were also the same for the two haemoglobins. However, even though the p50 of MalPEG-Hb is approx. half of that of HbA, the biphasic O2 dissociation rates measured at relatively high pO2 (150 Torr) were 2-fold higher, giving rise to a 2-fold lower R-state equilibrium association constant for MalPEG-Hb compared with HbA. Thus the O2 affinity of MalPEG-Hb is higher only at pO2 values lower than the intersection point of the O2 equilibrium curves for MalPEG-Hb and HbA. In summary, the present studies found similar rates of NO binding to HbA and MalPEG-Hb, eliminating the possibility that the lack of vasoactivity of MalPEG-Hb is simply the result of reduced molecular reactivity with NO. Alternatively, the unique O2-binding characteristics with low p50 and co-operativity suggest that the ‘R-state’ conformation of MalPEG-Hb is in a more T-state configuration and restricted from conformational change. PMID:15175010

  7. Serum Iron and Haemoglobin Estimation in Oral Submucous Fibrosis and Iron Deficiency Anaemia: A Diagnostic Approach.

    PubMed

    Bhardwaj, Divya; Dinkar, Ajit D; Satoskar, Sujata K; Desai, Sapna Raut

    2016-12-01

    Oral Submucous Fibrosis (OSMF) is a premalignant condition with potential malignant behaviour characterized by juxta-epithelial fibrosis of the oral cavity. In the process of collagen synthesis, iron gets utilized, by the hydroxylation of proline and lysine, leading to decreased serum iron levels. The trace element like iron is receiving much attention in the detection of oral cancer and precancerous condition like OSMF as it was found to be significantly altered in these conditions. The aim of this study was to compare the haemoglobin and serum iron values of OSMF subjects with that of iron deficiency anaemia subjects. Total of 120 subjects were included, 40 subjects with the OSMF, 40 with the iron deficiency anemia without tobacco chewing habit, 40 healthy control subjects without OSMF and iron deficiency anaemia. A total of 5ml of venous blood was withdrawn from all the subjects and serum iron and haemoglobin levels were estimated for all the subjects. Estimation of iron was done using Ferrozine method and haemoglobin by Sahli's method. The statistical method applied were Kruskal Wallis, Mann Whitney and Pearson correlation coefficient test. There was a statistically significant difference in serum iron and haemoglobin level in all three groups (p<0.05). The serum iron level was lowest in OSMF group and haemoglobin was lowest in iron deficiency anaemia group. A progressive decrease in serum iron and haemoglobin levels from Stage I of OSMF to the Stage IV of OSMF was also observed. The iron deficiency anaemia group was not found to be suffering from OSMF in the absence of areca-nut or tobacco chewing habits, but OSMF patients with chewing habits were found to be suffering from iron deficiency anaemia. There is a progressive decrease in serum iron and haemoglobin levels from Stage I of OSMF to the Stage IV of OSMF so it can be used as an auxillary test in assessment of prognosis of the disease.

  8. Serum Iron and Haemoglobin Estimation in Oral Submucous Fibrosis and Iron Deficiency Anaemia: A Diagnostic Approach

    PubMed Central

    Dinkar, Ajit D; Satoskar, Sujata K; Desai, Sapna Raut

    2016-01-01

    Introduction Oral Submucous Fibrosis (OSMF) is a premalignant condition with potential malignant behaviour characterized by juxta-epithelial fibrosis of the oral cavity. In the process of collagen synthesis, iron gets utilized, by the hydroxylation of proline and lysine, leading to decreased serum iron levels. The trace element like iron is receiving much attention in the detection of oral cancer and precancerous condition like OSMF as it was found to be significantly altered in these conditions. Aim The aim of this study was to compare the haemoglobin and serum iron values of OSMF subjects with that of iron deficiency anaemia subjects. Materials and Methods Total of 120 subjects were included, 40 subjects with the OSMF, 40 with the iron deficiency anemia without tobacco chewing habit, 40 healthy control subjects without OSMF and iron deficiency anaemia. A total of 5ml of venous blood was withdrawn from all the subjects and serum iron and haemoglobin levels were estimated for all the subjects. Estimation of iron was done using Ferrozine method and haemoglobin by Sahli’s method. The statistical method applied were Kruskal Wallis, Mann Whitney and Pearson correlation coefficient test. Results There was a statistically significant difference in serum iron and haemoglobin level in all three groups (p<0.05). The serum iron level was lowest in OSMF group and haemoglobin was lowest in iron deficiency anaemia group. A progressive decrease in serum iron and haemoglobin levels from Stage I of OSMF to the Stage IV of OSMF was also observed. The iron deficiency anaemia group was not found to be suffering from OSMF in the absence of areca-nut or tobacco chewing habits, but OSMF patients with chewing habits were found to be suffering from iron deficiency anaemia. Conclusion There is a progressive decrease in serum iron and haemoglobin levels from Stage I of OSMF to the Stage IV of OSMF so it can be used as an auxillary test in assessment of prognosis of the disease. PMID

  9. Blunted Myocardial Oxygenation Response During Vasodilator Stress in Patients With Hypertrophic Cardiomyopathy

    PubMed Central

    Karamitsos, Theodoros D.; Dass, Sairia; Suttie, Joseph; Sever, Emily; Birks, Jacqueline; Holloway, Cameron J.; Robson, Matthew D.; Jerosch-Herold, Michael; Watkins, Hugh; Neubauer, Stefan

    2013-01-01

    Objectives This study sought to assess myocardial perfusion and tissue oxygenation during vasodilator stress in patients with overt hypertrophic cardiomyopathy (HCM), as well as in HCM mutation carriers without left ventricular (LV) hypertrophy, and to compare findings to those in athletes with comparable hypertrophy and normal controls. Background Myocardial perfusion under vasodilator stress is impaired in patients with HCM. Whether this is associated with impaired myocardial oxygenation and tissue ischemia is unknown. Furthermore, it is not known whether perfusion and oxygenation are impaired in HCM mutation carriers without left ventricular hypertrophy (LVH). Methods A total of 27 patients with overt HCM, 10 HCM mutation carriers without LVH, 11 athletes, and 20 healthy controls underwent cardiovascular magnetic resonance (CMR) scanning at 3-T. Myocardial function, perfusion (perfusion reserve index [MPRI]), and oxygenation (blood-oxygen level dependent signal intensity [SI] change) under adenosine stress were assessed. Results MPRI was significantly reduced in HCM (1.3 ± 0.1) compared to controls (1.8 ± 0.1, p < 0.001) and athletes (2.0 ± 0.1, p < 0.001), but remained normal in HCM mutation carriers without LVH (1.7 ± 0.1; p = 0.61 vs. controls, p = 0.02 vs. overt HCM). Oxygenation response was attenuated in overt HCM (SI change 6.9 ± 1.4%) compared to controls (18.9 ± 1.4%, p < 0.0001) and athletes (18.7 ± 2.0%, p < 0.001). Interestingly, HCM mutation carriers without LVH also showed an impaired oxygenation response to adenosine (10.4 ± 2.0%; p = 0.001 vs. controls, p = 0.16 vs. overt HCM, p = 0.003 vs. athletes). Conclusions In overt HCM, both perfusion and oxygenation are impaired during vasodilator stress. However, in HCM mutation carriers without LVH, only oxygenation is impaired. In athletes, stress perfusion and oxygenation are normal. CMR assessment of myocardial oxygenation has the potential to become a novel risk factor in HCM. PMID:23498131

  10. Oxygenation-Enhanced Radiation Therapy of Breast Tumors

    DTIC Science & Technology

    2011-11-01

    development of stabilized perfluorocarbon emulsions as oxygen carriers, their characterization, and response to external triggers, including...elevated temperature, reduced pressure, and dwell time. Targeted oxygenation, perfluorocarbon emulsions, breast cancer 29 The University of Utah Salt...investigation of the proposed novel strategy of radio sensitization of hypoxic breast tumors by targeted oxygen release from perfluorocarbon oxygen

  11. Non-invasive multiwavelength photoplethysmography under low partial pressure of oxygen.

    PubMed

    Fang, Yung Chieh; Tai, Cheng-Chi

    2016-08-01

    A reduction in partial pressure of oxygen in the environment may be caused by a gain in altitude, which reduces the atmospheric pressure; it may also be caused by the carbon dioxide generated from breathing in an enclosed space. Does inhaling oxygen of lower partial pressure affect the oxygen-carrying function of haemoglobin in vivo? This study uses non-invasive multiwavelength photoplethysmography to measure the effects that inhaling this type of oxygen can have on the plethysmography of the appendages of the body (fingertips). The results indicate that under low partial pressure of oxygen, be it the result of a gain in carbon dioxide concentration or altitude, the change in visible light absorption is the biggest for short wavelengths (approximately 620 or 640 nm) near deoxyhaemoglobin, which has higher absorption coefficient. Moreover, increasing carbon dioxide concentration from 5000 to 10,000 ppm doubly reduces the absorption rate of these short wavelengths.

  12. Haemoglobin concentrations and infection by Giardia intestinalis in children: effect of treatment with secnidazole.

    PubMed

    Jiménez, J C; Rodríguez, N; Di Prisco, M C; Lynch, N R; Costa, V

    1999-12-01

    The blood concentrations of haemoglobin were investigated in 82 children aged 2-9 years. Fifty-seven (31 boys and 26 girls) were stool-positive for Giardia intestinalis but the other 25, used as controls, were negative. The mean (S.D.) haemoglobin concentration among the infected children was significantly lower pre-treatment than that for the control group [11.6 (1.2) v. 12.6 (1.5) g/dl; P < 0.05]. Treatment of the infected children with a single oral dose of secnidazole (30 mg/kg) led to a significant increase in their mean haemoglobin level 15 days later, from 11.6 (1.2) g/dl pre-treatment to 12.4 (1.2) g/dl post-treatment (P < 0.05). The results indicate that the therapeutic control of giardiasis could be important in programmes to combat anaemia in children living in endemic areas.

  13. High-performance multilayer WSe 2 field-effect transistors with carrier type control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pudasaini, Pushpa Raj; Oyedele, Akinola; Zhang, Cheng

    In this paper, high-performance multilayer WSe 2 field-effect transistor (FET) devices with carrier type control are demonstrated via thickness modulation and a remote oxygen plasma surface treatment. Carrier type control in multilayer WSe 2 FET devices with Cr/Au contacts is initially demonstrated by modulating the WSe 2 thickness. The carrier type evolves with increasing WSe 2 channel thickness, being p-type, ambipolar, and n-type at thicknesses <3, ~4, and >5 nm, respectively. The thickness-dependent carrier type is attributed to changes in the bandgap of WSe 2 as a function of the thickness and the carrier band offsets relative to the metalmore » contacts. Furthermore, we present a strong hole carrier doping effect via remote oxygen plasma treatment. It non-degenerately converts n-type characteristics into p-type and enhances field-effect hole mobility by three orders of magnitude. Finally, this work demonstrates progress towards the realization of high-performance multilayer WSe 2 FETs with carrier type control, potentially extendable to other transition metal dichalcogenides, for future electronic and optoelectronic applications.« less

  14. High-performance multilayer WSe 2 field-effect transistors with carrier type control

    DOE PAGES

    Pudasaini, Pushpa Raj; Oyedele, Akinola; Zhang, Cheng; ...

    2017-07-06

    In this paper, high-performance multilayer WSe 2 field-effect transistor (FET) devices with carrier type control are demonstrated via thickness modulation and a remote oxygen plasma surface treatment. Carrier type control in multilayer WSe 2 FET devices with Cr/Au contacts is initially demonstrated by modulating the WSe 2 thickness. The carrier type evolves with increasing WSe 2 channel thickness, being p-type, ambipolar, and n-type at thicknesses <3, ~4, and >5 nm, respectively. The thickness-dependent carrier type is attributed to changes in the bandgap of WSe 2 as a function of the thickness and the carrier band offsets relative to the metalmore » contacts. Furthermore, we present a strong hole carrier doping effect via remote oxygen plasma treatment. It non-degenerately converts n-type characteristics into p-type and enhances field-effect hole mobility by three orders of magnitude. Finally, this work demonstrates progress towards the realization of high-performance multilayer WSe 2 FETs with carrier type control, potentially extendable to other transition metal dichalcogenides, for future electronic and optoelectronic applications.« less

  15. Comparative genome-wide analysis and evolutionary history of haemoglobin-processing and haem detoxification enzymes in malarial parasites.

    PubMed

    Ponsuwanna, Patrath; Kochakarn, Theerarat; Bunditvorapoom, Duangkamon; Kümpornsin, Krittikorn; Otto, Thomas D; Ridenour, Chase; Chotivanich, Kesinee; Wilairat, Prapon; White, Nicholas J; Miotto, Olivo; Chookajorn, Thanat

    2016-01-29

    Malaria parasites have evolved a series of intricate mechanisms to survive and propagate within host red blood cells. Intra-erythrocytic parasitism requires these organisms to digest haemoglobin and detoxify iron-bound haem. These tasks are executed by haemoglobin-specific proteases and haem biocrystallization factors that are components of a large multi-subunit complex. Since haemoglobin processing machineries are functionally and genetically linked to the modes of action and resistance mechanisms of several anti-malarial drugs, an understanding of their evolutionary history is important for drug development and drug resistance prevention. Maximum likelihood trees of genetic repertoires encoding haemoglobin processing machineries within Plasmodium species, and with the representatives of Apicomplexan species with various host tropisms, were created. Genetic variants were mapped onto existing three-dimensional structures. Genome-wide single nucleotide polymorphism data were used to analyse the selective pressure and the effect of these mutations at the structural level. Recent expansions in the falcipain and plasmepsin repertoires are unique to human malaria parasites especially in the Plasmodium falciparum and P. reichenowi lineage. Expansion of haemoglobin-specific plasmepsins occurred after the separation event of Plasmodium species, but the other members of the plasmepsin family were evolutionarily conserved with one copy for each sub-group in every Apicomplexan species. Haemoglobin-specific falcipains are separated from invasion-related falcipain, and their expansions within one specific locus arose independently in both P. falciparum and P. vivax lineages. Gene conversion between P. falciparum falcipain 2A and 2B was observed in artemisinin-resistant strains. Comparison between the numbers of non-synonymous and synonymous mutations suggests a strong selective pressure at falcipain and plasmepsin genes. The locations of amino acid changes from non

  16. Brain RVD-haemopressin, a haemoglobin-derived peptide, inhibits bombesin-induced central activation of adrenomedullary outflow in the rat.

    PubMed

    Tanaka, Kenjiro; Shimizu, Takahiro; Yanagita, Toshihiko; Nemoto, Takayuki; Nakamura, Kumiko; Taniuchi, Keisuke; Dimitriadis, Fotios; Yokotani, Kunihiko; Saito, Motoaki

    2014-01-01

    Haemopressin and RVD-haemopressin, derived from the haemoglobin α-chain, are bioactive peptides found in brain and are ligands for cannabinoid CB1 receptors. Activation of brain CB1 receptors inhibited the secretion of adrenal catecholamines (noradrenaline and adrenaline) induced by i.c.v. bombesin in the rat. Here, we investigated the effects of two haemoglobin-derived peptides on this bombesin-induced response Anaesthetised male Wistar rats were pretreated with either haemoglobin-derived peptide, given i.c.v., 30 min before i.c.v. bombesin and plasma catecholamines were subsequently measured electrochemically after HPLC. Direct effects of bombesin on secretion of adrenal catecholamines were examined using bovine adrenal chromaffin cells. Furthermore, activation of haemoglobin α-positive spinally projecting neurons in the rat hypothalamic paraventricular nucleus (PVN, a regulatory centre of central adrenomedullary outflow) after i.c.v. bombesin was assessed by immunohistochemical techniques. Bombesin given i.c.v. dose-dependently elevated plasma catecholamines whereas incubation with bombesin had no effect on spontaneous and nicotine-induced secretion of catecholamines from chromaffin cells. The bombesin-induced increase in catecholamines was inhibited by pretreatment with i.c.v. RVD-haemopressin (CB1 receptor agonist) but not after pretreatment with haemopressin (CB1 receptor inverse agonist). Bombesin activated haemoglobin α-positive spinally projecting neurons in the PVN. The haemoglobin-derived peptide RVD-haemopressin in the brain plays an inhibitory role in bombesin-induced activation of central adrenomedullary outflow via brain CB1 receptors in the rat. These findings provide basic information for the therapeutic use of haemoglobin-derived peptides in the modulation of central adrenomedullary outflow. © 2013 The British Pharmacological Society.

  17. Hot Carrier-Based Near-Field Thermophotovoltaic Energy Conversion.

    PubMed

    St-Gelais, Raphael; Bhatt, Gaurang Ravindra; Zhu, Linxiao; Fan, Shanhui; Lipson, Michal

    2017-03-28

    Near-field thermophotovoltaics (NFTPV) is a promising approach for direct conversion of heat to electrical power. This technology relies on the drastic enhancement of radiative heat transfer (compared to conventional blackbody radiation) that occurs when objects at different temperatures are brought to deep subwavelength distances (typically <100 nm) from each other. Achieving such radiative heat transfer between a hot object and a photovoltaic (PV) cell could allow direct conversion of heat to electricity with a greater efficiency than using current solid-state technologies (e.g., thermoelectric generators). One of the main challenges in the development of this technology, however, is its incompatibility with conventional silicon PV cells. Thermal radiation is weak at frequencies larger than the ∼1.1 eV bandgap of silicon, such that PV cells with lower excitation energies (typically 0.4-0.6 eV) are required for NFTPV. Using low bandgap III-V semiconductors to circumvent this limitation, as proposed in most theoretical works, is challenging and therefore has never been achieved experimentally. In this work, we show that hot carrier PV cells based on Schottky junctions between silicon and metallic films could provide an attractive solution for achieving high efficiency NFTPV electricity generation. Hot carrier science is currently an important field of research and several approaches are investigated for increasing the quantum efficiency (QE) of hot carrier generation beyond conventional Fowler model predictions. If the Fowler limit can indeed be overcome, we show that hot carrier-based NFTPV systems-after optimization of their thermal radiation spectrum-could allow electricity generation with up to 10-30% conversion efficiencies and 10-500 W/cm 2 generated power densities (at 900-1500 K temperatures). We also discuss how the unique properties of thermal radiation in the extreme near-field are especially well suited for investigating recently proposed approaches

  18. Research on performance requirements of turbofan engine used on carrier-based UAV

    NASA Astrophysics Data System (ADS)

    Zhao, Shufan; Li, Benwei; Zhang, Wenlong; Wu, Heng; Feng, Tang

    2017-05-01

    According to the mission requirements of the carrier-based unmanned aerial vehicle (UAV), a mode level flight was established to calculate the thrust requirements from altitude 9 km to 13 km. Then, the estimation method of flight profile was used to calculate the weight of UAV in each stage to get the specific fuel consumption requirements of the UAV in standby stage. The turbofan engine of carrier-based UAV should meet the thrust and specific fuel consumption requirements. Finally, the GSP software was used to verify the simulation of a small high-bypass turbofan engine. The conclusion is useful for the turbofan engine selection of carrier-based UAV.

  19. Preoperative haemoglobin cut-off values for the prediction of post-operative transfusion in total knee arthroplasty.

    PubMed

    Yeh, Jared Ze Yang; Chen, Jerry Yongqiang; Bin Abd Razak, Hamid Rahmatullah; Loh, Bryan Huai Gu; Hao, Ying; Yew, Andy Khye Soon; Chia, Shi-Lu; Lo, Ngai Nung; Yeo, Seng Jin

    2016-10-01

    The purpose of this study is to determine preoperative haemoglobin cut-off values that could accurately predict post-operative transfusion outcome in patients undergoing primary unilateral total knee arthroplasty (TKA). This will allow surgeons to provide selective preoperative type and screen to only patients at high risk of transfusion. A total of 1457 patients diagnosed with osteoarthritis and underwent primary unilateral TKA between January 2012 and December 2014 were retrospectively reviewed. Logistic regression analyses were applied to identify factors that could predict transfusion outcome. A total of 37 patients (2.5 %) were transfused postoperatively. Univariate analysis revealed preoperative haemoglobin (p < 0.001), age (p < 0.001), preoperative haematocrit (p < 0.001), and preoperative creatinine (p < 0.001) to be significant predictors. In the multivariate analysis with patients dichotomised at 70 years of age, preoperative haemoglobin remained significant with adjusted odds ratio of 0.33. Receiver operating characteristic curve identified the preoperative haemoglobin cut-off values to be 12.4 g/dL (AUC = 0.86, sensitivity = 87.5 %, specificity = 77.2 %) and 12.1 g/dL (AUC = 0.85, sensitivity = 69.2 %, specificity = 87.1 %) for age above and below 70, respectively. The authors recommend preoperative haemoglobin cut-off values of 12.4 g/dL for age above 70 and 12.1 g/dL for age below 70 to be used to predict post-operative transfusion requirements in TKA. To maximise the utilisation of blood resources, the authors recommend that only patients with haemoglobin level below the cut-off should receive routine preoperative type and screen before TKA. IV.

  20. Hepcidin plasma levels are not associated with changes in haemoglobin in early rheumatoid arthritis patients.

    PubMed

    Østgård, R D; Glerup, H; Jurik, A G; Kragstrup, T W; Stengaard-Pedersen, K; Hetland, M L; Hørslev-Petersen, K; Junker, P; Deleuran, B W

    2017-11-01

    A reduction in haemoglobin level is a frequent complication among rheumatoid arthritis (RA) patients. Hepcidin has been linked to disturbed erythropoiesis. The objective of this study was to investigate the longitudinal changes in hepcidin in patients with early RA. Hepcidin plasma concentrations were measured by enzyme-linked immunosorbent assay in patients with early RA (n = 80) and healthy volunteers (HV, n = 40). Haemoglobin and other iron-related proteins were also measured. At baseline, all patients had active disease and were treatment naïve. Patients were treated with disease-modifying anti-rheumatic drugs (DMARDs) and with additional adalimumab (ADA, n = 42) or placebo (PLA, n = 38) during 52 weeks, using a treat-to-target strategy, aiming for a 28-joint Disease Activity Score (DAS28) < 3.2. At baseline, hepcidin levels [median (interquartile range)] were 9.7 ng/mL (5.2-19.4 ng/mL) in DMARD + ADA and 11.3 ng/mL (5.9-19.1 ng/mL) in DMARD + PLA. Both were significantly higher than seen in HV (6.0 ng/mL (3.3-9.3 ng/mL) (p < 0.001). After 12 months, both treatment regimens resulted in normalization of hepcidin. DAS28 correlated with hepcidin at baseline (r = 0.48, p < 0.001). No correlation was observed between levels of haemoglobin and hepcidin at baseline or during the 52 week follow-up. No change in haemoglobin levels was seen as a function of hepcidin changes. In a mixed statistical model, no single factor was connected with the regulation of haemoglobin in early RA. The changes in hepcidin were not associated with changes in haemoglobin levels. Thus, hepcidin could not be used as a prognostic marker in patients with early RA.

  1. Conditions for a carrier multiplication in amorphous-selenium based photodetector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Masuzawa, Tomoaki; Kuniyoshi, Shingo; Onishi, Masanori

    2013-02-18

    Amorphous selenium is a promising candidate for high sensitivity photodetector due to its unique carrier multiplication phenomenon. More than 10 carriers can be generated per incident photon, which leads to high photo-conversion efficiency of 1000% that allows real-time imaging in dark ambient. However, application of this effect has been limited to specific devices due to the lack in material characterization. In this article, mechanism of carrier multiplication has been clarified using time-of-flight secondary ion mass spectroscopy and Raman spectroscopy. A prototype photodetector achieved photo conversion efficiency of 4000%, which explains the signal enhancement mechanism in a-Se based photodetector.

  2. Preparation of hemoglobin-loaded nano-sized particles with porous structure as oxygen carriers.

    PubMed

    Zhao, Jian; Liu, Chang-Sheng; Yuan, Yuan; Tao, Xin-Yi; Shan, Xiao-Qian; Sheng, Yan; Wu, Fan

    2007-03-01

    Hb (hemoglobin)-loaded particles (HbP) encapsulated by a biodegradable polymer used as oxygen carrier were prepared. A modified double emulsion and solvent diffusion/evaporation method was adopted. All experiments were performed based on two types of biodegradable polymers, poly(epsilon-caprolactone) (PCL) and poly(epsilon-caprolactone-ethylene glycol) (PCL-PEG). The biodistribution and the survival time in blood of the particles were investigated in a mouse model. Encapsulation efficiency and pore-connecting efficiency were evaluated by a novel sulfocyanate potassium method. The influence of process parameters on the particle size and pore-connecting efficiency (PCE%) of nanoparticles have been discussed. The prepared conditions: solvent, external aqueous phase, pressure were discussed. The system utilizing dichloromethane (DCM)/ethyl acetate (EA) as a solvent with an unsaturated external aqueous phase yielded the highest encapsulation efficiency (87.35%) with a small mean particle size (153 nm). The formation of porous channels was attributed to the diffusion of solvent. The PCE% was more sensitive to the rate of solvent diffusion that was obviously affected by the preparation temperature. The PCE% reached 87.47% when PCL-PEG was employed at 25 degrees C. P(50) of HbP was 27 mmHg, which does not seem to be greatly affected by the encapsulation procedure. In vivo, following intravenous injection of 6-coumarin labeled HbP, the major organ accumulating Hb-loaded particles was the liver. The half-life of nano-sized PCL HbP was 3.1 times as long as the micro-sized PCL HbP. Also, Nano-sized as well as a PEGylated surface on HbP is beneficial for prolonged blood residence (7.2 fold increase).

  3. 2,3-diphosphoglycerate and oxygen supply of tissues in cardiosurgical diabetics.

    PubMed

    Beder, I; Mataseje, A; Kittova, M; Carsky, J; Fischer, V

    2005-01-01

    The oxygen supply of tissues was studied under haemodilution in cardiosurgical diabetic and non-diabetic patients. There were 30 cardiosurgery patients examined, 9 were patients with diabetes mellitus.and 21 were non-diabetic patients. Venous blood samples were examined preoperatively, intraoperatively and for 10 days after operation. Haemodilution caused a decrease in haematocrit values in both groups, as well as in the erythrocyte count and haemoglobin concentration. Postoperatively, an increase was recorded in haematological values in both groups, the values had not reached the baseline even by 10th day. Increased values of blood oxygen saturation and partial oxygen pressure during the operation returned to baseline in both groups in the postoperative days. Values of p50 did not change in both groups for the period of observation. The obtained data suggest that sufficient oxygen supply to tissues was ensured under haemodilution in cardiosurgery patients in both groups. These results confirm multifactorial dependence of blood oxygen transport to tissues (Tab. 1, Fig. 3, Ref. 13).

  4. Active medium gain study of electric-discharge oxygen-iodine laser

    NASA Astrophysics Data System (ADS)

    Kolobyanin, Yuriy; Adamenkov, Yuriy; Vyskubenko, Boris; Goryachev, Leonid; Ilyin, Sergey; Kalashnik, Anatoliy; Rakhimova, Tatiana; Rogozhnikov, Georgiy

    2007-05-01

    The paper reports on experimental studies of the active medium gain in supersonic electric-discharge oxygen-iodine laser (DOIL) based on traveling mw discharge. The measurements have included: absolute concentration, yield, and energy efficiency of production of SO in pure oxygen and oxygen-helium mixes at an oxygen partial pressure 3 to 15 Torr. For the gas flow to get rid of atomic oxygen, both heterogeneous mercury oxide coatings of the tube walls and homogeneous additives to the work mix, such as nitrogen oxide, have been used. The active medium of DOIL was formed using a nozzle array of the type of ejector sized as 10*50 mm2. The singlet oxygen-helium mix was supplied through three rows of sonic cylindrical nozzles, while the iodine-carrier gas mix - through two rows of supersonic conical nozzles with a half-opening angle of 10°(arc). The gas-phase iodine was produced in a quartz cell filled with iodine crystals. Room-temperature iodine vapors were picked up with a carrier gas (nitrogen or helium) and thus delivered into the nozzle array. The active medium was investigated by the high-resolution laser diode spectroscopy approach that used the laser type Vortex 6025 purchased from New Focus, Inc. The laser medium gain factor was determined by the intra-cavity approach having a sensitivity about 1*10 -6 cm -1. The static temperature of the medium was determined from the measurements of gain half-width. The gain of the active medium of electric-discharge OIL has been investigated. The DOIL in use was operating on a mix composed as O II:He=1:1 at a total pressure of 6 Torr and flowrate - about 1 mmol/s. With helium as an iodine carrier gas at a flowrate ~3 mmol/s, we have recorded a positive gain in the DOIL medium.

  5. Recombinant vs native Anisakis haemoglobin (Ani s 13): Its appraisal as a new gold standard for the diagnosis of allergy.

    PubMed

    González-Fernández, Juan; Rivas, Luis; Luque-Ortega, Juan Román; Núñez-Ramírez, Rafael; Campioli, Pamela; Gárate, Teresa; Perteguer, María J; Daschner, Alvaro; Cuéllar, Carmen

    2017-10-01

    Recombinant allergens are currently the best option for serodiagnosis of human anisakiasis in terms of sensitivity and specificity. However, previous reports showed high rates of anisakiasis patients who were negative to Ani s 7 and especially to Ani s 1. Recently, Anisakis haemoglobin was described as a major allergen (Ani s 13). Although Ani s 13 belongs to a conserved protein family, it seems not to be a cross-reacting antigen because of the absence of IgE recognition against Ascaris haemoglobin in Anisakis patients. The aim of this study is to develop a more sensitive and specific diagnosis tool for Anisakis based on the recently discovered allergen Ani s 13. We obtained and purified recombinant Anisakis haemoglobin (rAni s 13) and the native form (nAni s 13). The recognition of both recombinant and native haemoglobins by anti-haemoglobin IgE from patients' sera was assessed by indirect ELISA and immunoblotting using 43 Anisakis sensitised patients and 44 non-Anisakis sensitised patients. Native Ani s 13 was also treated with periodate to study if oxidation of glycans destroys antibody binding. Furthermore, it was structurally characterised by negative staining electron microscopy and analytical ultracentrifugation. Recombinant Ani s 13 was only recognised by four patients with gastro-allergic anisakiasis (GAA) and immunoblotting analyses showed no bands. However, nAni s 13 was detected by 72.1% of Anisakis sensitised patients measured by indirect ELISA. Particularly, 18 (90%) out of 20 GAA patients were positive. Tetramers and octamers were the most abundant homomers of nAni s 13 but octamers had higher content of bound heme. None of the non-Anisakis sensitised patients were positive. Combined use of purified native form of Ani s 13 with current gold standards would improve the sensitivity and specificity for diagnosing anisakiasis. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. A solvent-based intelligence ink for oxygen.

    PubMed

    Mills, Andrew; Hazafy, David

    2008-02-01

    A solvent-based, irreversible oxygen indicator ink is described, comprising semiconductor photocatalyst nanoparticles, a solvent-soluble redox dye, mild reducing agent and polymer. Based on such an ink, a film -- made of titanium dioxide, a blue, solvent-soluble, coloured ion-paired methylene blue dye, glycerol and the polymer zein -- loses its colour rapidly (<30 s) upon exposure to UVA light and remains colourless in an oxygen-free atmosphere, returning to its original blue colour upon exposure to air. In the latter step the rate of colour recovery is proportional to the level of ambient oxygen and the same film can be UV-activated repeatedly. The mechanism of this novel, UV-activated, solvent-based, colorimetric oxygen indicator is discussed, along with its possible applications.

  7. A simulation model of the oxygen alveolo-capillary exchange in normal and pathological conditions.

    PubMed

    Brighenti, Chiara; Gnudi, Gianni; Avanzolini, Guido

    2003-05-01

    This paper presents a mathematical model of the oxygen alveolo-capillary exchange to provide the capillary oxygen partial pressure profile in normal and pathological conditions. In fact, a thickening of the blood-gas barrier, heavy exercise or a low oxygen partial pressure (PO2) in the alveolar space can reduce the O2 alveolo-capillary exchange. Since the reversible binding between haemoglobin and oxygen makes it impossible to determine the closed form for the mathematical description of the PO2 profile along the pulmonary capillaries, an approximate analytical solution of the capillary PO2 profile is proposed. Simulation results are compared with the capillary PO2 profile obtained by numerical integration and by a piecewise linear interpolation of the oxyhaemoglobin dissociation curve. Finally, the proposed model is evaluated in a large range of physiopathological diffusive conditions. The good fit to numerical solutions in all experimental conditions seems to represent a substantial improvement with respect to the approach based on a linear approximation of the oxyhaemoglobin dissociation curve, and makes this model a candidate to be incorporated into the integrated descriptions of the entire respiratory system, where the datum of primary interest is the value of end capillary PO2.

  8. Material quality frontiers of MOVPE grown AlGaAs for minority carrier devices

    NASA Astrophysics Data System (ADS)

    Heckelmann, S.; Lackner, D.; Dimroth, F.; Bett, A. W.

    2017-04-01

    In this study, secondary ion mass spectroscopy of oxygen, deep level transient spectroscopy and power dependent relative photoluminescence are compared regarding their ability to resolve differences in AlxGa1-xAs material quality. AlxGa1-xAs samples grown with two different trimethylaluminum sources showing low and high levels of oxygen contamination are compared. As tested in the growth of minority carrier devices, i.e. AlxGa1-xAs solar cells, the two precursors clearly lead to different device characteristics. It is shown that secondary ion mass spectroscopy could not resolve the difference in oxygen concentration, whereas deep level transient spectroscopy and photoluminescence based measurements indicate the influence of the precursor oxygen level on the material quality.

  9. The effect of golimumab on haemoglobin levels in patients with rheumatoid arthritis, psoriatic arthritis or ankylosing spondylitis.

    PubMed

    Furst, Daniel E; Kay, Jonathan; Wasko, Mary Chester; Keystone, Edward; Kavanaugh, Arthur; Deodhar, Atul; Murphy, Frederick T; Magnus, Jeanette H; Hsia, Elizabeth C; Hsu, Benjamin; Xu, Stephen; Rahman, Mahboob U; Doyle, Mittie K

    2013-10-01

    To evaluate the effect of golimumab on haemoglobin levels in patients with RA, PsA or AS. Secondary analysis was performed on integrated data from five randomized controlled studies: three RA, one PsA and one AS (2303 patients total). Golimumab 50 or 100 mg was injected s.c. every 4 weeks with or without MTX. Control groups received placebo injections plus MTX or background therapy. Patients with haemoglobin levels below the age- and sex-specific normal ranges were considered to have anaemia. Ferritin levels were used to distinguish anaemia of mixed aetiology (≥ 15 and <60 ng/ml) and anaemia of inflammation (≥ 60 ng/ml). Changes from baseline to weeks 14 and 24 in haemoglobin level were compared between treatment groups using an analysis of variance on the van der Waerden normal scores. At baseline, 21% of RA patients, 9% of PsA patients and 15% of AS patients had anaemia. Of these, 24%, 57% and 25%, respectively, had anaemia of inflammation. The median increase from baseline to week 14 in the haemoglobin level of anaemic patients was 0.3 g/dl in the control group and 0.9 g/dl in the golimumab group (P < 0.001). Haemoglobin levels improved within the subgroups of patients with anaemia of mixed aetiology (control, 0.4 g/dl vs golimumab, 0.7 g/dl) (P = 0.305) and with anaemia of inflammation (0.2 vs 1.4 g/dl, respectively) (P < 0.001). Compared with the control group, patients receiving golimumab treatment had significantly improved haemoglobin levels, particularly among patients with anaemia of inflammation.

  10. Association between maternal haemoglobin and stillbirth: a cohort study among a multi-ethnic population in England.

    PubMed

    Nair, Manisha; Churchill, David; Robinson, Susan; Nelson-Piercy, Cathy; Stanworth, Simon J; Knight, Marian

    2017-12-01

    The study objectives were to examine the association of maternal haemoglobin with stillbirth and perinatal death in a multi-ethnic population in England. We conducted a retrospective cohort analysis using anonymised maternity data from 14 001 women with singleton pregnancies ≥24 weeks' gestation giving birth between 2013 and 2015 in two hospitals - the Royal Wolverhampton NHS Trust and Guy's and St Thomas' NHS Foundation Trust. Multivariable logistic regression analyses were undertaken to analyse the associations between maternal haemoglobin at first visit and at 28 weeks with stillbirth and perinatal death, adjusting for 11 other risk factors. Results showed that 46% of the study population had anaemia (haemoglobin <110 g/l) at some point during their pregnancy. The risk of stillbirth and perinatal death decreased linearly per unit increase in haemoglobin concentration at first visit (adjusted odds ratio [aOR] stillbirth = 0·70, 95% confidence interval [CI] 0·58-0·85, aOR perinatal death = 0·71, 95% CI 0·60-0·84) and at 28 weeks (aOR stillbirth = 0·83, 95% CI 0·66-1·04; aOR perinatal death = 0·86, 95%CI 0·67-1·12). Compared with women with haemoglobin ≥110 g/l, the risk of stillbirth and perinatal death was five- and three-fold higher in women with moderate-severe anaemia (haemoglobin <100 g/l) at first visit and 28 weeks, respectively. These findings have clinical and public health importance. © 2017 The Authors. British Journal of Haematology published by John Wiley & Sons Ltd.

  11. Tuning the thermoelectric properties of A-site deficient SrTiO3 ceramics by vacancies and carrier concentration.

    PubMed

    Srivastava, Deepanshu; Norman, Colin; Azough, Feridoon; Schäfer, Marion C; Guilmeau, Emmanuel; Kepaptsoglou, Demie; Ramasse, Quentin M; Nicotra, Giuseppe; Freer, Robert

    2016-09-29

    Ceramics based on Sr 0.8 La 0.067 Ti 0.8 Nb 0.2 O 3-δ have been prepared by the mixed oxide route. The La 1/3 NbO 3 component generates ∼13.4% A-site vacancies; this was fixed for all samples. Powders were sintered under air and reducing conditions at 1450 to 1700 K; products were of high density (>90% theoretical). Processing under reducing conditions led to the formation of a Ti 1-x Nb x O 2-y second phase, core-shell structures and oxygen deficiency. X-ray diffraction (XRD) confirmed a simple cubic structure with space group Pm3[combining macron]m. Transmission electron microscopy revealed a high density of dislocations while analytical scanning transmission electron microscopy at atomic resolution demonstrated a uniform distribution of La, Nb and vacancies in the lattice. X-ray photoemission spectroscopy and thermogravimetry showed the oxygen deficiency (δ value) to be ∼0.08 in reduced samples with enhanced carrier concentrations ∼2 × 10 21 cm -3 . Both carrier concentration and carrier mobility increased with sintering time, giving a maximum figure of merit (ZT) of 0.25. Selective additional doping by La or Nb, with no additional A site vacancies, led to the creation of additional carriers and reduced electrical resistivity. Together these led to enhanced ZT values of 0.345 at 1000 K. The contributions from oxygen vacancies and charge carriers have been investigated independently.

  12. Anisakis haemoglobin is a main antigen inducing strong and prolonged immunoreactions in rats.

    PubMed

    Abe, Niichiro; Teramoto, Isao

    2017-07-01

    Anisakis simplex larvae are well known to cause gastrointestinal and allergic manifestations after ingestion of parasitized raw or undercooked seafood. The antibody recognition dynamics against the components of Anisakis larval antigen after primary and re-infection with Anisakis live larvae remain unclear. For this study, immunoblot analyses of serum IgG, IgE, and IgM against Anisakis larval somatic extract were performed in rats that had been orally inoculated with A. simplex live larvae. Multiple antigen fractions were recognized after primary infection. Their reaction was enhanced after re-infection. Antibody recognition was observed for 12 weeks after re-infection. The fraction of approximately 35 kDa contained a main antigen that induced strong and prolonged immunoreactions in IgG and IgE. The antibody reaction to this fraction appeared to be enhanced after inoculation of larval homogenates. This fraction was heat tolerant with boiling for 30 min. The fraction was spotted by immunoblotting after two-dimensional electrophoresis and was identified as Anisakis haemoglobin (Ani s 13) using mass spectrometry analysis. The amino acid sequences of haemoglobin mRNAs from two A. simplex sensu stricto and one Anisakis pegreffii were identified by RACE-PCR. They differed from those of two isolates of Pseudoterranova decipiens and A. pegreffii. Results of this study show that Anisakis haemoglobin, which is known to be a major allergen of A. simplex, induces strong and prolonged immunoreaction in rats. This report is the first to show the amino acid sequence variation of Anisakis haemoglobin mRNA between A. simplex sensu stricto and A. pegreffii.

  13. Reversible Oxygenation of 2,4-Diaminobutanoic Acid-Co(II) Complexes

    PubMed Central

    Li, Hui; Yue, Fan; Wen, Hongmei

    2016-01-01

    This paper introduces the structural characterization and studies on reversible oxygenation behavior of a new oxygen carrier Co(II)-2,4-diaminobutanoic acid (DABA) complex in aqueous solution. The composition of the oxygenated complex was determined by gas volumetric method, molar ratio method, and mass spectrometry, and the formula of the oxygenated complex was determined to be [Co(DABA)2O2]. In aqueous solution, the complex can continuously uptake and release dioxygen and exhibit excellent reversibility of oxygenation and deoxygenation ability. This complex can maintain 50% of its original oxygenation capacity after 30 cycles in 24 h and retain 5% of the original oxygenation capacity after more than 260 cycles after 72 h. When a ligand analogue was linked to histidine (His), the new complex exhibited as excellent reversible oxygenation property as His-Co(II) complex. Insight into the relationship between structural detail and oxygenation properties will provide valuable suggestion for a new family of oxygen carriers. PMID:27648004

  14. Threshold Haemoglobin Levels and the Prognosis of Stable Coronary Disease: Two New Cohorts and a Systematic Review and Meta-Analysis

    PubMed Central

    Shah, Anoop D.; Nicholas, Owen; Timmis, Adam D.; Feder, Gene; Abrams, Keith R.; Chen, Ruoling; Hingorani, Aroon D.; Hemingway, Harry

    2011-01-01

    Background Low haemoglobin concentration has been associated with adverse prognosis in patients with angina and myocardial infarction (MI), but the strength and shape of the association and the presence of any threshold has not been precisely evaluated. Methods and findings A retrospective cohort study was carried out using the UK General Practice Research Database. 20,131 people with a new diagnosis of stable angina and no previous acute coronary syndrome, and 14,171 people with first MI who survived for at least 7 days were followed up for a mean of 3.2 years. Using semi-parametric Cox regression and multiple adjustment, there was evidence of threshold haemoglobin values below which mortality increased in a graded continuous fashion. For men with MI, the threshold value was 13.5 g/dl (95% confidence interval [CI] 13.2–13.9); the 29.5% of patients with haemoglobin below this threshold had an associated hazard ratio for mortality of 2.00 (95% CI 1.76–2.29) compared to those with haemoglobin values in the lowest risk range. Women tended to have lower threshold haemoglobin values (e.g, for MI 12.8 g/dl; 95% CI 12.1–13.5) but the shape and strength of association did not differ between the genders, nor between patients with angina and MI. We did a systematic review and meta-analysis that identified ten previously published studies, reporting a total of only 1,127 endpoints, but none evaluated thresholds of risk. Conclusions There is an association between low haemoglobin concentration and increased mortality. A large proportion of patients with coronary disease have haemoglobin concentrations below the thresholds of risk defined here. Intervention trials would clarify whether increasing the haemoglobin concentration reduces mortality. Please see later in the article for the Editors' Summary PMID:21655315

  15. Respiratory physicians and clinic coordinators' attitudes to population-based cystic fibrosis carrier screening.

    PubMed

    Cunningham, Fiona; Lewis, Sharon; Curnow, Lisette; Glazner, Judith; Massie, John

    2014-01-01

    Attitudes of Australian CF healthcare professionals toward population-based cystic fibrosis (CF) carrier screening were examined. A purpose-designed questionnaire was distributed to 111 respiratory physicians and 30 CF clinic coordinators throughout Australia. Seventy-one questionnaires (52 physicians and 19 coordinators (46.8%, 63.3% respectively)) were returned. Forty respondents (56.3%) supported population-based carrier screening for CF. Support for screening was associated with rating the factors: carrier risk being 1 in 25 (OR 1.72 (1.12, 2.65)), reassurance when both partners test negative (OR 1.67 (1.12, 2.46)) and the daily treatment regimen for CF patients (OR 1.59 (1.05, 2.42)) as important. Opposition to screening was associated with identifying potential discrimination against carriers as a disadvantage (OR 0.3 (0.12, 0.88)), and limitations of predicting clinical outcomes as a barrier (OR 0.46 (0.25, 0.83)). There is moderate support for population-based carrier screening for CF by Australian CF healthcare professionals. Perceived barriers to implementation are surmountable. © 2013.

  16. Carrier-phase-based two-way satellite time and frequency transfer.

    PubMed

    Fujieda, Miho; Gotoh, Tadahiro; Nakagawa, Fumimaru; Tabuchi, Ryo; Aida, Masanori; Amagai, Jun

    2012-12-01

    We performed measurements of carrier-phase-based two-way satellite time and frequency transfer (TWST-FT) with an A/D sampler and conventional TWSTFT system. We found that an instability resulting from a local signal at the satellite transponder was negligible. The short-term stability of 4 × 10(-13) at 1 s was achieved in a short-baseline measurement. The results showed good agreement with the GPS carrier phase.

  17. Sorbent-based Oxygen Production for Energy Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sethi, Vijay

    Project DE-FE0024075 deals with the development of a moderate-temperature sorbent-based oxygen production technology. Sorbent-based oxygen production process utilizes oxygen-storage properties of Perovskites to (1) adsorb oxygen from air in a solid sorbent, and (2) release the adsorbed oxygen into a sweep gas such as CO 2 and/or steam for gasification systems or recycled flue gas for oxy-combustion systems. Pure oxygen can be produced by the use of vacuum instead of a sweep gas to affect the pressure swing. By developing more efficient and stable, higher sorption capacity, newer class of materials operating at moderate temperatures this process represents a majormore » advancement in air separation technology. Newly developed perovskite ceramic sorbent materials with order-disorder transition have a higher O 2 adsorption capacity, potentially 200 °C lower operating temperatures, and up to two orders of magnitude faster desorption rates than those used in earlier development efforts. The performance advancements afforded by the new materials lead to substantial savings in capital investment and operational costs. Cost of producing oxygen using sorbents could be as much as 26% lower than VPSA and about 13% lower than a large cryogenic air separation unit. Cost advantage against large cryogenic separation is limited because sorbent-based separation numbers up sorbent modules for achieving the larger capacity.« less

  18. Performance indicators for carrier-based DPIs: Carrier surface properties for capsule filling and API properties for in vitro aerosolisation.

    PubMed

    Faulhammer, E; Zellnitz, S; Wutscher, T; Stranzinger, S; Zimmer, A; Paudel, A

    2018-01-30

    This study investigates engineered carrier, as well as engineered API particles, and shows that there are distinct performance indicators of particle engineering for carrier-based dry powder inhalers (DPIs). Spray dried (SDSS) and jet-milled (JMSS) salbutamol sulphate (SS) was blended with untreated α-lactose monohydrate (LAC_R) and α-lactose monohydrate engineered (LAC_E). Subsequent capsule filling was performed with different process settings on a dosator nozzle capsule filling machine in order to reach a target fill weight of 20-25 mg. To evaluate the performance of the different mixtures, in vitro lung deposition experiments were carried out with a next generation impactor, the emitted dose (ED) and fine particle fraction (FPF) were calculated based on the specification of the European pharmacopoeia. The FPF of micronised powder blends is significantly higher (20%) compared to the FPF of spray dried blends (5%). Compared to API engineering, carrier engineering had a positive effect on the capsule filling performance (weight variability and mean fill weight) at lower compression ratios (setting 1). Results further showed that higher compression ratios appear to be beneficial in terms of capsule filling performance (higher fill weight and less fill weight variation). Concluding, it can be stated that the carrier engineering, or generally carrier properties, govern downstream processing, whereas the API engineering and API properties govern the aerosolisation performance and thereby significantly affect the dose delivery to the lungs. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. From tissue iron retention to low systemic haemoglobin levels, new pathophysiological biomarkers of human abdominal aortic aneurysm.

    PubMed

    Martinez-Pinna, R; Lindholt, J S; Madrigal-Matute, J; Blanco-Colio, L M; Esteban-Salan, M; Torres-Fonseca, M M; Lefebvre, T; Delbosc, S; Laustsen, J; Driss, F; Vega de Ceniga, M; Gouya, L; Weiss, G; Egido, J; Meilhac, O; Michel, J-B; Martin-Ventura, J

    2014-07-03

    Iron deposits are observed in tissue of abdominal aortic aneurysm (AAA) patients, although the underlying mechanisms are not completely elucidated. Therefore we explored circulating markers of iron metabolism in AAA patients, and tested if they could serve as biomarkers of AAA. Increased red blood cell (RBC)-borne iron retention and transferrin, transferrin receptor and ferritin expression was observed in AAA tissue compared to control aorta (immunohistochemistry and western blot). In contrast, decreased circulating iron, transferrin, mean corpuscular haemoglobin concentration (MCHC) and haemoglobin concentration, along with circulating RBC count, were observed in AAA patients (aortic diameter >3 cm, n=114) compared to controls (aortic diameter <3 cm, n=88) (ELISA), whereas hepcidin concentrations were increased in AAA subjects (MS/MS assay). Moreover, iron, transferrin and haemoglobin levels were negatively, and hepcidin positively, correlated with aortic diameter in AAA patients. The association of low haemoglobin with AAA presence or aortic diameter was independent of specific risk factors. Moreover, MCHC negatively correlated with thrombus area in another cohort of AAA patients (aortic diameter 3-5 cm, n=357). We found that anaemia was significantly more prevalent in AAA patients (aortic diameter >5 cm, n=8,912) compared to those in patients with atherosclerotic aorto-iliac occlusive disease (n=17,737) [adjusted odds ratio=1.77 (95% confidence interval: 1.61;1.93)]. Finally, the mortality risk among AAA patients with anaemia was increased by almost 30% [adjusted hazard ratio: 1.29 (95% confidence interval: 1.16;1.44)] as compared to AAA subjects without anaemia. In conclusion, local iron retention and altered iron recycling associated to high hepcidin and low transferrin systemic concentrations could lead to reduced circulating haemoglobin levels in AAA patients. Low haemoglobin levels are independently associated to AAA presence and clinical outcome.

  20. [Delivery room resuscitation with room air and oxygen in newborns. State of art, recommendations].

    PubMed

    Lauterbach, Ryszard; Musialik-Swietlińska, Ewa; Swietliński, Janusz; Pawlik, Dorota; Bober, Klaudiusz

    2008-01-01

    The authors present and discuss the current data, concerning delivery room resuscitation with oxygen and room air in neonates. On the ground of the results obtained from literature and the Polish National Survey on Paediatric and Neonatal Intensive Care, 2007/2008 issue, the authors give the following proposals regarding optimal oxygen treatment: 1. there is a need for optimizing tissue oxygenation in order to prevent injury caused by radical oxygen species; 2. newborn resuscitation should be monitored by measuring the haemoglobin saturation - the values above 90%, found in resuscitated newborn within the first minutes of life may be dangerous and cause tissue injury; 3. starting the resuscitation with oxygen concentration lower than 40% and adjusting it according to the effects of the procedure - the less mature infant the lower oxygen concentration at the beginning of resuscitation; 4. heart rate >100/min and SatO2Hb between 70-80% within the first minutes of life should not be an indication for increasing oxygen concentration.

  1. Sickle-cell haemoglobin C disease in London

    PubMed Central

    Black, A. J.; Condon, P. I.; Gompels, B. M.; Green, R. L.; Huntsman, R. G.; Jenkins, G. C.

    1972-01-01

    The manifestations of the sickling disorders are becoming increasingly familiar to clinicians in Great Britain. One of these disorders, sickle-cell haemoglobin disease, has hitherto received little attention, being regarded as a relatively mild condition. This paper describes some of the distinctive clinical features of the disease as seen in a series of nine cases which have recently presented in London, two of which were fatal. The special hazards of the condition in relation to pregnancy, air travel, and general anaesthesia are discussed. Images PMID:5015374

  2. Haemoglobin content modulated deformation dynamics of red blood cells on a compact disc.

    PubMed

    Kar, Shantimoy; Ghosh, Uddipta; Maiti, Tapas Kumar; Chakraborty, Suman

    2015-12-21

    We investigate the deformation characteristics of red blood cells (RBCs) on a rotating compact disc platform. Our study brings out the interplay between haemoglobin content and RBC deformability in a centrifugally actuated microfluidic environment. We reveal that RBC deformations follow the similar trend of principal stress distributed throughout the radial direction, rendering an insight into the mechano-physical processes involved. This study can be used as a diagnostic marker to determine haematological disorders in diseased blood samples tested on compact disc based microfluidic platforms.

  3. Anaemia during pregnancy: impact on birth outcome and infant haemoglobin level during the first 18 months of life.

    PubMed

    Koura, Ghislain K; Ouedraogo, Smaïla; Le Port, Agnès; Watier, Laurence; Cottrell, Gilles; Guerra, José; Choudat, Isabelle; Rachas, Antoine; Bouscaillou, Julie; Massougbodji, Achille; Garcia, André

    2012-03-01

    To determine the effect of maternal anaemia on pregnancy outcome and describe its impact on infant haemoglobin level in the first 18 months of life, we conducted a prospective study of 617 pregnant women and their children in Benin. Prevalence of maternal anaemia at delivery was 39.5%, and 61.1% of newborns were anaemic at birth. Maternal anaemia was not associated with low birth weight [OR = 1.2 (0.6-2.2)] or preterm birth [OR = 1.3 (0.7-2.4)], whereas the newborn's anaemia was related to maternal anaemia [OR = 1.8 (1.2-2.5)]. There was no association between an infant's haemoglobin level until 18 months and maternal anaemia. However, malaria attacks during follow-up, male gender and sickle cell trait were all associated with a lower infant haemoglobin level until 18 months, whereas good infant feeding practices and a polygamous family were positively associated with a higher haemoglobin level during the first 18 months of life. © 2011 Blackwell Publishing Ltd.

  4. Effects of two fractions of inspired oxygen during anesthesia on early postanesthesia oxygenation in healthy dogs.

    PubMed

    Martin-Flores, Manuel; Tseng, Chia T; Robillard, Steven D; Abrams, Brittany E; Campoy, Luis; Harvey, H Jay; Gleed, Robin D

    2018-02-01

    OBJECTIVE To evaluate the effects of 2 fractions of inspired oxygen (Fio 2 s) during anesthesia on postanesthesia Pao 2 and other measures of oxygen exchange. ANIMALS 22 healthy adult sexually intact female dogs undergoing ovariohysterectomy by ventral midline celiotomy. PROCEDURES Dogs were randomly assigned to receive either oxygen (Fio 2 > 0.9 [100% oxygen]; n = 11; control group) or a mixture of nitrogen and oxygen (Fio 2 = 0.4; 11; 40% oxygen group) as the carrier gas for isoflurane while anesthetized. All dogs were allowed to breathe spontaneously while anesthetized. For each dog, the Pao 2 , Paco 2 , other indices of oxygenation, and extent of sedation were monitored at predetermined times during and for 1 hour after anesthesia. Measured variables were compared between the 2 treatment groups and over time within each treatment group. RESULTS None of the measured variables differed significantly between the control and 40% oxygen groups at any time during the postanesthesia period. Within each treatment group, the Paco 2 and extent of sedation decreased over time during the postanesthesia period. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that indices of oxygenation did not differ significantly between healthy dogs in which the Fio 2 was maintained at > 0.9 and those in which the Fio 2 was maintained at 0.4 while anesthetized for ovariohysterectomy. Thus, the addition of nitrogen to the carrier gas for an inhalant anesthetic conferred neither an advantage nor disadvantage in regard to oxygenation during the first hour of anesthesia recovery.

  5. A universal array-based multiplexed test for cystic fibrosis carrier screening.

    PubMed

    Amos, Jean A; Bridge-Cook, Philippa; Ponek, Victor; Jarvis, Michael R

    2006-01-01

    Cystic fibrosis is a multisystem autosomal recessive disorder with high carrier frequencies in caucasians and significant, but lower, carrier frequencies in other ethnicities. Based on technology that allows high detection of mutations in caucasians and significant detection in other ethnic groups, the American College of Medical Genetics (ACMG) and American College of Obstetricians and Gynecologists (ACOG) have recommended pan-ethnic cystic fibrosis carrier screening for all reproductive couples. This paper discusses carrier screening using the Tag-It multiplex mutation platform and the Cystic Fibrosis Mutation Detection Kit. The Tag-It cystic fibrosis assay is a multiplexed genotyping assay that detects a panel of 40 cystic fibrosis transmembrane conductance regulator mutations including the 23 mutations recommended by the ACMG and ACOG for population screening. A total of 16 additional mutations detected by the Tag-It cystic fibrosis assay may also be common. The assay method is described in detail, and its performance in a genetics reference laboratory performing high-volume cystic fibrosis carrier screening is assessed.

  6. Single-cell-based system to monitor carrier driven cellular auxin homeostasis

    PubMed Central

    2013-01-01

    Background Abundance and distribution of the plant hormone auxin play important roles in plant development. Besides other metabolic processes, various auxin carriers control the cellular level of active auxin and, hence, are major regulators of cellular auxin homeostasis. Despite the developmental importance of auxin transporters, a simple medium-to-high throughput approach to assess carrier activities is still missing. Here we show that carrier driven depletion of cellular auxin correlates with reduced nuclear auxin signaling in tobacco Bright Yellow-2 (BY-2) cell cultures. Results We developed an easy to use transient single-cell-based system to detect carrier activity. We use the relative changes in signaling output of the auxin responsive promoter element DR5 to indirectly visualize auxin carrier activity. The feasibility of the transient approach was demonstrated by pharmacological and genetic interference with auxin signaling and transport. As a proof of concept, we provide visual evidence that the prominent auxin transport proteins PIN-FORMED (PIN)2 and PIN5 regulate cellular auxin homeostasis at the plasma membrane and endoplasmic reticulum (ER), respectively. Our data suggest that PIN2 and PIN5 have different sensitivities to the auxin transport inhibitor 1-naphthylphthalamic acid (NPA). Also the putative PIN-LIKES (PILS) auxin carrier activity at the ER is insensitive to NPA in our system, indicating that NPA blocks intercellular, but not intracellular auxin transport. Conclusions This single-cell-based system is a useful tool by which the activity of putative auxin carriers, such as PINs, PILS and WALLS ARE THIN1 (WAT1), can be indirectly visualized in a medium-to-high throughput manner. Moreover, our single cell system might be useful to investigate also other hormonal signaling pathways, such as cytokinin. PMID:23379388

  7. Haemoglobin concentration and the risk of death in older adults: differences by race/ethnicity in the NHANES III follow-up.

    PubMed

    Patel, Kushang V; Longo, Dan L; Ershler, William B; Yu, Binbing; Semba, Richard D; Ferrucci, Luigi; Guralnik, Jack M

    2009-05-01

    Mildly low haemoglobin concentration is associated with increased mortality in older adults. However, this relationship has not been well characterized in racial/ethnic minorities. Therefore, this study determined the haemoglobin threshold below which risk of death is significantly increased in older non-Hispanic whites, non-Hispanic blacks, and Mexican Americans. Data on 4089 participants of the 1988-94 US National Health and Nutrition Examination Survey who were > or =65 years of age were analyzed with mortality follow-up through December 31, 2000. Mean haemoglobin in non-Hispanic whites (n = 2686) and Mexican Americans (n = 663) was 140 g/l, while in non-Hispanic blacks (n = 740) the mean was 10 g/l lower. A total of 1944 (47.5%) participants died. Among non-Hispanic whites and Mexican Americans, age- and sex-adjusted models showed that the haemoglobin thresholds below which mortality risk was significantly increased were 4 and 2 g/l respectively, above the World Health Organization (WHO) cut-off points for anaemia. In contrast, the threshold for non-Hispanic blacks was 7 g/l below the WHO criteria. Similar threshold effects were observed when analyzing haemoglobin in categories and adjusting for multiple confounders. In conclusion, the haemoglobin threshold below which mortality rises significantly is a full g/dl lower in non-Hispanic blacks than in non-Hispanic whites and Mexican Americans.

  8. Blood oxygenation level dependent functional magnetic resonance imaging: current and potential uses in obstetrics and gynaecology

    PubMed Central

    Vincent, K; Moore, J; Kennedy, S; Tracey, I

    2008-01-01

    Blood-oxygenation-level-dependent functional magnetic resonance imaging is a noninvasive technique that has become increasingly popular in the neurosciences. It measures the proportion of oxygenated haemoglobin in specific areas of the brain, mirroring blood flow and therefore function. Here we review how the findings from functional studies impact on areas of gynaecological practice as diverse as chronic pain, continence, and premenstrual dysphoric disorder. Finally we review some of the more novel applications of the technique, such as imaging of pelvic floor function and the effects of hypoxia on the fetus. PMID:19076956

  9. Monitorization of the effects of spinal anaesthesia on cerebral oxygen saturation in elder patients using near-infrared spectroscopy.

    PubMed

    Kusku, Aysegul; Demir, Guray; Cukurova, Zafer; Eren, Gulay; Hergunsel, Oya

    2014-01-01

    Central blockage provided by spinal anaesthesia enables realization of many surgical procedures, whereas hemodynamic and respiratory changes influence systemic oxygen delivery leading to the potential development of series of problems such as cerebral ischemia, myocardial infarction and acute renal failure. This study was intended to detect potentially adverse effects of hemodynamic and respiratory changes on systemic oxygen delivery using cerebral oxymetric methods in patients who underwent spinal anaesthesia. Twenty-five ASA I-II Group patients aged 65-80 years scheduled for unilateral inguinal hernia repair under spinal anaesthesia were included in the study. Following standard monitorization baseline cerebral oxygen levels were measured using cerebral oximetric methods. Standardized Mini Mental Test (SMMT) was applied before and after the operation so as to determine the level of cognitive functioning of the cases. Using a standard technique and equal amounts of a local anaesthetic drug (15mg bupivacaine 5%) intratechal blockade was performed. Mean blood pressure (MBP), maximum heart rate (MHR), peripheral oxygen saturation (SpO2) and cerebral oxygen levels (rSO2) were preoperatively monitored for 60min. Pre- and postoperative haemoglobin levels were measured. The variations in data obtained and their correlations with the cerebral oxygen levels were investigated. Significant changes in pre- and postoperative measurements of haemoglobin levels and SMMT scores and intraoperative SpO2 levels were not observed. However, significant variations were observed in intraoperative MBP, MHR and rSO2 levels. Besides, a correlation between variations in rSO2, MBP and MHR was determined. Evaluation of the data obtained in the study demonstrated that post-spinal decline in blood pressure and also heart rate decreases systemic oxygen delivery and adversely effects cerebral oxygen levels. However, this downward change did not result in deterioration of cognitive functioning

  10. [Monitorization of the effects of spinal anaesthesia on cerebral oxygen saturation in elder patients using near-infrared spectroscopy].

    PubMed

    Kusku, Aysegul; Demir, Guray; Cukurova, Zafer; Eren, Gulay; Hergunsel, Oya

    2014-01-01

    Central blockage provided by spinal anaesthesia enables realization of many surgical procedures, whereas hemodynamic and respiratory changes influence systemic oxygen delivery leading to the potential development of series of problems such as cerebral ischemia, myocardial infarction and acute renal failure. This study was intended to detect potentially adverse effects of hemodynamic and respiratory changes on systemic oxygen delivery using cerebral oxymetric methods in patients who underwent spinal anaesthesia. Twenty-five ASA I-II Group patients aged 65-80 years scheduled for unilateral inguinal hernia repair under spinal anaesthesia were included in the study. Following standard monitorization baseline cerebral oxygen levels were measured using cerebral oximetric methods. Standardized Mini Mental Test (SMMT) was applied before and after the operation so as to determine the level of cognitive functioning of the cases. Using a standard technique and equal amounts of a local anaesthetic drug (15mg bupivacaine 5%) intratechal blockade was performed. Mean blood pressure (MBP), maximum heart rate (MHR), peripheral oxygen saturation (SpO2) and cerebral oxygen levels (rSO2) were preoperatively monitored for 60min. Pre- and postoperative haemoglobin levels were measured. The variations in data obtained and their correlations with the cerebral oxygen levels were investigated. Significant changes in pre- and postoperative measurements of haemoglobin levels and SMMT scores and intraoperative SpO2 levels were not observed. However, significant variations were observed in intraoperative MBP, MHR and rSO2 levels. Besides, a correlation between variations in rSO2, MBP and MHR was determined. Evaluation of the data obtained in the study demonstrated that post-spinal decline in blood pressure and also heart rate decreases systemic oxygen delivery and adversely effects cerebral oxygen levels. However, this downward change did not result in deterioration of cognitive functioning

  11. Evaluation and costs of different haemoglobin methods for use in district hospitals in Malawi

    PubMed Central

    Medina Lara, A; Mundy, C; Kandulu, J; Chisuwo, L; Bates, I

    2005-01-01

    Aims: To evaluate the characteristics of manual haemoglobin methods in use in Malawi and provide evidence for the Ministry of Health in Malawi to enable them to choose a suitable method for district hospitals. Methods: Criteria on accuracy, clinical usefulness, user friendliness, speed, training time, and economic costs were determined by local health professionals and used to compare six different manual haemoglobin methods. These were introduced sequentially into use in a district hospital in Malawi alongside the reference method. Results: HemoCue was the optimal method based on most of the outcome measures but was also the most expensive (US$0.75/test). DHT meter and Jenway colorimeter were the second choice because they were cheaper (US$0.20–0.35/test), but they were not as accurate or user friendly as HemoCue. Conclusions: The process for choosing appropriate laboratory methods is complex and very little guidance is available for health managers in poorer countries. This paper describes the development and testing of a practical model for gathering evidence about test efficiency that could be adapted for use in other resource poor settings. PMID:15623483

  12. Core structures of haemosiderins deposited in various organs in β-thalassaemia/haemoglobin e disease

    NASA Astrophysics Data System (ADS)

    St. Pierre, T. G.; Tran, K. C.; Webb, J.; Macey, D. J.; Pootrakul, P.; Dickson, D. P. E.

    1992-04-01

    Mössbauer spectra were recorded of tissue from β-thalassaemia/haemoglobin E spleen, liver, pancreas and heart and of crude haemosiderins (insoluble iron fractions) isolated from the organs. Iron in the crude haemosiderins from the spleen and heart remains paramagnetic below 4.2K indicating that the iron is in a non-crystalline form. Superparamagnetic behaviour of the crude haemosiderins from the pancreas and liver indicate the presence of ferrihydrite cores with some cores with a structure based on defect-goethite.

  13. Newborn screening for sickling and other haemoglobin disorders using tandem mass spectrometry: A pilot study of methodology in laboratories in England.

    PubMed

    Daniel, Yvonne A; Henthorn, Joan

    2016-12-01

    To determine (i) if electrospray mass spectrometry-mass spectrometry with the SpOtOn Diagnostics Ltd reagent kit for sickle cell screening could be integrated into the English newborn screening programme, under routine screening conditions, and provide mass spectrometry-mass spectrometry results which match existing methods, and (ii) if common action values could be set for all manufacturers in the study, for all assessed haemoglobins, to indicate which samples require further investigation. Anonymised residual blood spots were analysed using the SpOtOn reagent kit as per manufacturer's instructions, in parallel with existing techniques at four laboratories. Mass spectrometry-mass spectrometry instrumentation at Laboratories A and B was AB Sciex (Warrington, UK) AP4000, and at Laboratories C and D, Waters Micromass (Manchester, UK), Xevo TQMS and Premier, respectively. There were 23,898 results accepted from the four laboratories. Excellent specificity at 100% sensitivity was observed for haemoglobin S, haemoglobin C, haemoglobin E and haemoglobin O Arab . A common action value was not possible for Hb C, but action values were set by manufacturer. The two haemoglobin D Punjab cases at Laboratory D were not detected using the common action value. Conversely, false-positive results with haemoglobin D Punjab were a problem at the remaining three laboratories. This multicentre study demonstrates that it is possible to implement mass spectrometry-mass spectrometry into an established screening programme while maintaining consistency with existing methods for haemoglobinopathy screening. However, one of the instruments investigated cannot be recommended for use with this application. © The Author(s) 2016.

  14. Correlation between capillary oxygen saturation and small intestinal wall thickness in the equine colic patient

    PubMed Central

    Mirle, Elisabeth; Wogatzki, Anna; Kunzmann, Robert; Schoenfelder, Axel M; Litzke, Lutz F

    2017-01-01

    The surgical evaluation of haemorrhagic infarcted intestine and the decision for or against bowel resection require a lot of experience and are subjective. The aim of this prospective, clinical study was to examine the correlation between oxygen saturation and small intestinal wall (IW) thickness, using two objective methods. In 22 colicky horses, the blood flow, oxygen saturation and relative amount of haemoglobin were measured intraoperatively via laser Doppler and white light spectroscopy (O2C, oxygen to see, LEA Medizintechnik) at six measuring points (MPs) in small and large intestines. Furthermore, the IW thickness was measured ultrasonographically. Nine of 22 horses had an increased small IW thickness greater than 4 mm (Freeman 2002, Scharner and others 2002, le Jeune and Whitcomb 2014) at measuring point 1 (MP1) (strangulated segment), four horses had a thickened bowel wall at measuring point 3 (MP3) (poststenotic) and one at measuring point 2 (MP2). The oxygen saturation was 0 at MP1 in six horses, at MP3 in two horses and at MP2 (prestenotic) in one. Oxygen saturation and small IW thickness were independent of each other at MP1 and MP2. At MP3, the two parameters were negatively correlated. In summary, it is not possible to draw conclusions about oxygen saturation based on IW thickness. PMID:28761667

  15. Correlation between capillary oxygen saturation and small intestinal wall thickness in the equine colic patient.

    PubMed

    Mirle, Elisabeth; Wogatzki, Anna; Kunzmann, Robert; Schoenfelder, Axel M; Litzke, Lutz F

    2017-01-01

    The surgical evaluation of haemorrhagic infarcted intestine and the decision for or against bowel resection require a lot of experience and are subjective. The aim of this prospective, clinical study was to examine the correlation between oxygen saturation and small intestinal wall (IW) thickness, using two objective methods. In 22 colicky horses, the blood flow, oxygen saturation and relative amount of haemoglobin were measured intraoperatively via laser Doppler and white light spectroscopy (O2C, oxygen to see, LEA Medizintechnik) at six measuring points (MPs) in small and large intestines. Furthermore, the IW thickness was measured ultrasonographically. Nine of 22 horses had an increased small IW thickness greater than 4 mm (Freeman 2002, Scharner and others 2002, le Jeune and Whitcomb 2014) at measuring point 1 (MP1) (strangulated segment), four horses had a thickened bowel wall at measuring point 3 (MP3) (poststenotic) and one at measuring point 2 (MP2). The oxygen saturation was 0 at MP1 in six horses, at MP3 in two horses and at MP2 (prestenotic) in one. Oxygen saturation and small IW thickness were independent of each other at MP1 and MP2. At MP3, the two parameters were negatively correlated. In summary, it is not possible to draw conclusions about oxygen saturation based on IW thickness.

  16. Theranostic Oxygen Delivery Using Ultrasound and Microbubbles

    PubMed Central

    Kwan, James J.; Kaya, Mehmet; Borden, Mark A.; Dayton, Paul A.

    2012-01-01

    Means to overcome tumor hypoxia have been the subject of clinical investigations since the 1960's; however these studies have yet to find a treatment which is widely accepted. It has been known for nearly a century that hypoxic cells are more resistant to radiotherapy than aerobic cells, and tumor hypoxia is a major factor leading to the resistance of tumors to radiation treatment as well as several cytotoxic agents. In this manuscript, the application of ultrasound combined with oxygen-carrier microbubbles is demonstrated as a method to locally increase dissolved oxygen. Microbubbles can also be imaged by ultrasound, thus providing the opportunity for image-guided oxygen delivery. Simulations of gas diffusion and microbubble gas exchange show that small amounts (down to 5 vol%) of a low-solubility osmotic gas can substantially increase microbubble persistence and therefore production rates and stability of oxygen-carrier microbubbles. Simulations also indicate that the lipid shell can be engineered with long-chain lipids to increase oxygen payload during in vivo transit. Experimental results demonstrate that the application of ultrasound to destroy the microbubbles significantly enhances the local oxygen release. We propose this technology as an application for ultrasound image-guided release of oxygen directly to hypoxic tissue, such as tumor sites to enhance radiotherapy. PMID:23382774

  17. Maternal anaemia at delivery and haemoglobin evolution in children during their first 18 months of life using latent class analysis.

    PubMed

    Koura, Kobto G; Ouédraogo, Smaïla; Cottrell, Gilles; Le Port, Agnès; Massougbodji, Achille; Garcia, André

    2012-01-01

    Anaemia during pregnancy and at delivery is an important public health problem in low- and middle-income countries. Its association with the children's haemoglobin level over time remains unclear. Our goals were to identify distinct haemoglobin level trajectories using latent class analysis and to assess the association between these trajectories and maternal anaemia and other risk factors. A prospective study of children from birth to 18 months of life was conducted in a rural setting in Tori-Bossito, Benin. The main outcome measure was the haemoglobin levels repeatedly measured at 3, 6, 9, 12, 15 and 18 months. Variables were collected from the mothers at delivery and from their children at birth and during the follow-up. The analyses were performed by means of Latent Class Analysis which has never been used for this kind of data. All the analyses were performed with Stata software, version 11.0, using the generalized linear latent and mixed model (GLLAMM) framework. We showed that 33.7% of children followed a low haemoglobin trajectory and 66.3% a high trajectory during the first 18 months of life. Newborn anaemia, placental malaria, malaria attack, sickle cell trait and male gender were significantly associated with a lower children's haemoglobin level over time, whereas maternal age, children living in a polygamous family and with good feeding practices had a higher Hb level in the first18 months. We also showed that maternal anaemia was a predictor for 'low haemoglobin level trajectory' group membership but have no significant effect on children haemoglobin level over time. Latent Class Analyses framework seems well suited to analyse longitudinal data under the hypothesis that different subpopulations of subjects are present in the data, each with its own set of parameters, with distinctive evolutions that themselves may reflect distinctive aetiologies.

  18. Maternal Anaemia at Delivery and Haemoglobin Evolution in Children during Their First 18 Months of Life Using Latent Class Analysis

    PubMed Central

    Koura, Kobto G.; Ouédraogo, Smaïla; Cottrell, Gilles; Le Port, Agnès; Massougbodji, Achille; Garcia, André

    2012-01-01

    Background Anaemia during pregnancy and at delivery is an important public health problem in low- and middle-income countries. Its association with the children’s haemoglobin level over time remains unclear. Our goals were to identify distinct haemoglobin level trajectories using latent class analysis and to assess the association between these trajectories and maternal anaemia and other risk factors. Method A prospective study of children from birth to 18 months of life was conducted in a rural setting in Tori-Bossito, Benin. The main outcome measure was the haemoglobin levels repeatedly measured at 3, 6, 9, 12, 15 and 18 months. Variables were collected from the mothers at delivery and from their children at birth and during the follow-up. The analyses were performed by means of Latent Class Analysis which has never been used for this kind of data. All the analyses were performed with Stata software, version 11.0, using the generalized linear latent and mixed model (GLLAMM) framework. Results We showed that 33.7% of children followed a low haemoglobin trajectory and 66.3% a high trajectory during the first 18 months of life. Newborn anaemia, placental malaria, malaria attack, sickle cell trait and male gender were significantly associated with a lower children’s haemoglobin level over time, whereas maternal age, children living in a polygamous family and with good feeding practices had a higher Hb level in the first18 months. We also showed that maternal anaemia was a predictor for ‘low haemoglobin level trajectory’ group membership but have no significant effect on children haemoglobin level over time. Conclusion Latent Class Analyses framework seems well suited to analyse longitudinal data under the hypothesis that different subpopulations of subjects are present in the data, each with its own set of parameters, with distinctive evolutions that themselves may reflect distinctive aetiologies. PMID:23185556

  19. The relationship between helminth infections and low haemoglobin levels in Ethiopian children with blood type A.

    PubMed

    Degarege, A; Yimam, Y; Madhivanan, P; Erko, B

    2017-05-01

    The current study was conducted to evaluate the nature of association of ABO blood type with helminth infection and related reduction in haemoglobin concentration. Stool samples were collected from 403 school-age children attending Tikur Wuha Elementary School from February to April 2011. Helminth infection was examined using formol-ether concentration and thick Kato-Katz (two slides per stool specimen) techniques. Haemoglobin level was determined using a HemoCue machine and ABO blood type was determined using the antisera haemagglutination test. Nutritional status was assessed using height and weight measurements. Out of 403 children examined, 169, 120, 96 and 18 had blood type O, A, B and AB, respectively. The prevalences of helminth infections were 46.9% for hookworm, 24.6% for Schistosoma mansoni, 4.2% for Ascaris lumbricoides, 1.7% for Trichuris trichiura and 58.3% for any helminth species. The relative odds of infection with at least one helminth species was significantly higher among children with blood type A (adjusted odds ratio (AOR), 2.10; 95% confidence interval (CI), 1.28-3.45) or blood type B (AOR, 2.08; 95% CI, 1.22-3.56) as compared to children with blood type O. Among children infected with helminths, mean haemoglobin concentration was lower in those with blood type A than those with blood type O (β, -0.36; 95% CI, -0.72 to -0.01). The relative odds of hookworm infection (AOR, 1.78; 95% CI, 1.08-2.92) and related reduction in haemogobin levels (β, -0.45; 95% CI, -0.84 to -0.04) was higher among children with blood type A as compared to those with blood type O. Although the difference was not significant, the relative odds of S. mansoni or A. lumbricoides infections and related reduction in haemoglobin levels was also higher in children with blood type A or B as compared to children with blood type O. In conclusion, children with blood type A are associated with an increased risk of helminth, particularly hookworm, infection and related reduction

  20. B4C as a stable non-carbon-based oxygen electrode material for lithium-oxygen batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Shidong; Xu, Wu; Cao, Ruiguo

    Lithium-oxygen (Li-O 2) batteries have extremely high theoretical specific capacities and energy densities when compared with Li-ion batteries. However, the instability of both electrolyte and carbon-based oxygen electrode related to the nucleophilic attack of reduced oxygen species during oxygen reduction reaction and the electrochemical oxidation during oxygen evolution reaction are recognized as the major challenges in this field. Here we report the application of boron carbide (B 4C) as the non-carbon based oxygen electrode material for aprotic Li-O 2 batteries. B 4C has high resistance to chemical attack, good conductivity, excellent catalytic activity and low density that are suitable formore » battery applications. The electrochemical activity and chemical stability of B4C are systematically investigated in aprotic electrolyte. Li-O 2 cells using B4C based air electrodes exhibit better cycling stability than those used TiC based air electrode in 1 M LiTf-Tetraglyme electrolyte. The degradation of B 4C based electrode is mainly due to be the loss of active sites on B 4C electrode during cycles as identified by the structure and composition characterizations. These results clearly demonstrate that B 4C is a very promising alternative oxygen electrode material for aprotic Li-O 2 batteries. It can also be used as a standard electrode to investigate the stability of electrolytes.« less

  1. The synthesis and application of heparin-based smart drug carrier.

    PubMed

    Li, Qingxuan; Gan, Lu; Tao, Hong; Wang, Qian; Ye, Lin; Zhang, Aiying; Feng, Zengguo

    2016-04-20

    Heparin based polymer drug which could self-assemble into sphere micelle in water was firstly prepared by grafting paclitaxel (PTX) into the hydroxyl of heparin via aconitic bond as pH sensitive spacer. Positive charged drug DOX·HCl and cationic folic acid (CFA) can be further loaded into the polymer drug via electrostatic interaction in aqueous solution so as to prepare smart drug carrier. The drug carrier was able to release more PTX and DOX at pH 4.8 than that at pH 7.4, exhibiting pH sensitivity for two drugs. Furthermore, tumor cell cytotoxicity test proved it possessed significant cytotoxicity against tumor cells MDA-MB-231 as well as its active tumor targeting ability resulting from the loading of CFA. Cellular uptake and intracellular distribution were further revealed by confocal laser scanning microscopy (CLSM). In conclusion, this paper not only provided a simple strategy but also indicated heparin is a versatile platform for the design of smart drug carrier. The as-prepared drug carrier also showed promising potential in chemotherapy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Lipid-Based Nanoparticles as Pharmaceutical Drug Carriers: From Concepts to Clinic

    PubMed Central

    Puri, Anu; Loomis, Kristin; Smith, Brandon; Lee, Jae-Ho; Yavlovich, Amichai; Heldman, Eli; Blumenthal, Robert

    2010-01-01

    In recent years, various nanotechnology platforms in the area of medical biology, including both diagnostics and therapy, have gained remarkable attention. Moreover, research and development of engineered multifunctional nanoparticles as pharmaceutical drug carriers have spurred exponential growth in applications to medicine in the last decade. Design principles of these nanoparticles, including nano-emulsions, dendrimers, nano-gold, liposomes, drug-carrier conjugates, antibody-drug complexes, and magnetic nanoparticles, are primarily based on unique assemblies of synthetic, natural, or biological components, including but not limited to synthetic polymers, metal ions, oils, and lipids as their building blocks. However, the potential success of these particles in the clinic relies on consideration of important parameters such as nanoparticle fabrication strategies, their physical properties, drug loading efficiencies, drug release potential, and, most importantly, minimum toxicity of the carrier itself. Among these, lipid-based nanoparticles bear the advantage of being the least toxic for in vivo applications, and significant progress has been made in the area of DNA/RNA and drug delivery using lipid-based nanoassemblies. In this review, we will primarily focus on the recent advances and updates on lipid-based nanoparticles for their projected applications in drug delivery. We begin with a review of current activities in the field of liposomes (the so-called honorary nanoparticles), and challenging issues of targeting and triggering will be discussed in detail. We will further describe nanoparticles derived from a novel class of amphipathic lipids called bolaamphiphiles with unique lipid assembly features that have been recently examined as drug/DNA delivery vehicles. Finally, an overview of an emerging novel class of particles (based on lipid components other than phospholipids), solid lipid nanoparticles and nanostructured lipid carriers will be presented. We

  3. [Sauna effect on blood oxygen transport function and proxidant/antioxidant balance in youths].

    PubMed

    Zinchuk, V V; Zhad'ko, D D

    2012-01-01

    There was investigated sauna effect on blood oxygen transport function and proxidant/antioxidant balance in 18 to 22 years old males. Subjects being tested underwent thermal exposure once per week over a period of 5 months (20 procedures). There were two exposure over the course of sauna bathing (temperature 85-90 degrees C, humidity 10-15%): the first exposure lasted for 5 minutes and the second one for 10 minutes. Dry air sauna in youth's leads to respiratory alkalosis, increases pO2, decreases haemoglobin binding capacity to venous blood oxygen thus facilitating oxygen transport into body tissues. Single sauna visit results in oxidative stress (augmentation of free radical processes and deterioration of antioxidant defence mechanisms), while its manifestations being diminished after multiple thermal exposures. Increase in nitrogen monoxide formation being observed might matter for the modification of the oxygen dependent processes of the human body.

  4. Development and clinical evaluation of noninvasive near-infrared monitoring of cerebral oxygenation

    NASA Astrophysics Data System (ADS)

    Wickramasinghe, Yappa A.; Rolfe, Peter J.; Palmer, Keith; Watkins, S.; Spencer, S. A.; Doyle, M.; O'Brien, S.; Walker, A.; Rice, C.; Smallpeice, C.

    1994-02-01

    Near infrared spectroscopy (NIRS) is a relatively new method which is suitable for monitoring oxygenation in blood and tissue in the brain of the fetus and the neonate. The technique involves in-vivo determination of the absorption of light in the wavelength range 775 to 900 nm through such tissue and converting such changes in absorbance to provide information about the changes in the concentration of oxygenated and de-oxygenated haemoglobin (HbO2 and Hb). Recent developments of the methodology now enable the calculation of changes in cerebral blood volume (CBV) as well as absolute CBV and cerebral blood flow (CBF). The attraction of this method is its applicability to monitor cerebral function in a wide variety of patient groups. Although primarily developed for neonatal use it is today applied on the fetus to investigate fetal hypoxia and on adults undergoing surgery.

  5. Charge carrier transport in polycrystalline organic thin film based field effect transistors

    NASA Astrophysics Data System (ADS)

    Rani, Varsha; Sharma, Akanksha; Ghosh, Subhasis

    2016-05-01

    The charge carrier transport mechanism in polycrystalline thin film based organic field effect transistors (OFETs) has been explained using two competing models, multiple trapping and releases (MTR) model and percolation model. It has been shown that MTR model is most suitable for explaining charge carrier transport in grainy polycrystalline organic thin films. The energetic distribution of traps determined independently using Mayer-Neldel rule (MNR) is in excellent agreement with the values obtained by MTR model for copper phthalocyanine and pentacene based OFETs.

  6. Reversible Oxygen Gas Sensor Based On Electrochemiluminescence

    PubMed Central

    Zhang, Lihua; Tsow, Francis

    2013-01-01

    A novel and robust oxygen gas sensor based on electrochemiluminescence of Ru(bpy)33+/+ ion annihilation in an ionic liquid is presented. Real-time detection of environmental oxygen concentration together with selective, sensitive and reversible performance is demonstrated. PMID:20386795

  7. Reduced fecundity in male ALS gene-carriers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, W.G.; Lustenberger, A.; Lucek, P.R.

    1995-11-06

    In order to study genetic aspects in multicase families, 89 amyotrophic lateral sclerosis (ALS) and 214 Parkinson disease (PD) kindreds were analyzed in parallel studies. Obligate gene-carriers were identified as described previously. There were fewer children per gene-carrier male (2.42) than per gene-carrier female (3.25, Student`s t-test, P<.0003) for ALS but not for other diseases. The data taken together suggest that fecundity in ALS gene-carriers was reduced in males, possibly as a result of reduced fertility. Since childbearing is usually accomplished well before the onset of neurological symptoms in ALS, and since reduced fecundity was found in male ALS gene-carriers,more » these findings raise the possibility that an ALS gene might have a pleiotrophic effect on fertility in males occurring decades before the onset of neurological symptoms. Evidence is presented linking reactive oxygen species to reduced fertility in males. Alternatively, decreased or nonfunctional androgen receptors could play a role. 22 refs., 1 fig., 2 tabs.« less

  8. Structural basis for ligand and innate immunity factor uptake by the trypanosome haptoglobin-haemoglobin receptor.

    PubMed

    Lane-Serff, Harriet; MacGregor, Paula; Lowe, Edward D; Carrington, Mark; Higgins, Matthew K

    2014-12-12

    The haptoglobin-haemoglobin receptor (HpHbR) of African trypanosomes allows acquisition of haem and provides an uptake route for trypanolytic factor-1, a mediator of innate immunity against trypanosome infection. In this study, we report the structure of Trypanosoma brucei HpHbR in complex with human haptoglobin-haemoglobin (HpHb), revealing an elongated ligand-binding site that extends along its membrane distal half. This contacts haptoglobin and the β-subunit of haemoglobin, showing how the receptor selectively binds HpHb over individual components. Lateral mobility of the glycosylphosphatidylinositol-anchored HpHbR, and a ∼50° kink in the receptor, allows two receptors to simultaneously bind one HpHb dimer. Indeed, trypanosomes take up dimeric HpHb at significantly lower concentrations than monomeric HpHb, due to increased ligand avidity that comes from bivalent binding. The structure therefore reveals the molecular basis for ligand and innate immunity factor uptake by trypanosomes and identifies adaptations that allow efficient ligand uptake in the context of the complex trypanosome cell surface.

  9. Binary lipids-based nanostructured lipid carriers for improved oral bioavailability of silymarin.

    PubMed

    Shangguan, Mingzhu; Lu, Yi; Qi, Jianping; Han, Jin; Tian, Zhiqiang; Xie, Yunchang; Hu, Fuqiang; Yuan, Hailong; Wu, Wei

    2014-02-01

    The main purpose of this study was to prepare binary lipids-based nanostructured lipid carriers to improve the oral bioavailability of silymarin, a poorly water-soluble liver protectant. Silymarin-loaded nanostructured lipid carriers were prepared by the method of high-pressure homogenization with glycerol distearates (Precirol ATO-5) and oleic acid as the solid and liquid lipids, respectively, and lecithin (Lipoid E 100) and Tween-80 as the emulsifiers. The silymarin-nanostructured lipid carrier prepared under optimum conditions was spherical in shape with mean particle size of ∼78.87 nm, entrapment efficiency of 87.55%, loading capacity of 8.32%, and zeta potential of -65.3 mV, respectively. In vitro release of silymarin-nanostructured lipid carriers was very limited even after 12 h, while in vitro lipolysis showed fast digestion of nanostructured lipid carriers within 1 h. Relative oral bioavailability of silymarin-nanostructured lipid carriers in Beagle dogs was 2.54- and 3.10-fold that of marketed Legalon® and silymarin solid dispersion pellets, respectively. It was concluded that nanostructured lipid carriers were potential drug delivery systems to improve the bioavailability of silymarin. Other than improved dissolution, alternative mechanisms such as facilitated absorption as well as lymphatic transport may contribute to bioavailability enhancement.

  10. Endothelial cell expression of haemoglobin α regulates nitric oxide signalling.

    PubMed

    Straub, Adam C; Lohman, Alexander W; Billaud, Marie; Johnstone, Scott R; Dwyer, Scott T; Lee, Monica Y; Bortz, Pamela Schoppee; Best, Angela K; Columbus, Linda; Gaston, Benjamin; Isakson, Brant E

    2012-11-15

    Models of unregulated nitric oxide (NO) diffusion do not consistently account for the biochemistry of NO synthase (NOS)-dependent signalling in many cell systems. For example, endothelial NOS controls blood pressure, blood flow and oxygen delivery through its effect on vascular smooth muscle tone, but the regulation of these processes is not adequately explained by simple NO diffusion from endothelium to smooth muscle. Here we report a new model for the regulation of NO signalling by demonstrating that haemoglobin (Hb) α (encoded by the HBA1 and HBA2 genes in humans) is expressed in human and mouse arterial endothelial cells and enriched at the myoendothelial junction, where it regulates the effects of NO on vascular reactivity. Notably, this function is unique to Hb α and is abrogated by its genetic depletion. Mechanistically, endothelial Hb α haem iron in the Fe(3+) state permits NO signalling, and this signalling is shut off when Hb α is reduced to the Fe(2+) state by endothelial cytochrome b5 reductase 3 (CYB5R3, also known as diaphorase 1). Genetic and pharmacological inhibition of CYB5R3 increases NO bioactivity in small arteries. These data reveal a new mechanism by which the regulation of the intracellular Hb α oxidation state controls NOS signalling in non-erythroid cells. This model may be relevant to haem-containing globins in a broad range of NOS-containing somatic cells.

  11. Nanostructured Lipid Carriers (NLC) as Vehicles for Topical Administration of Sesamol: In Vitro Percutaneous Absorption Study and Evaluation of Antioxidant Activity.

    PubMed

    Puglia, Carmelo; Lauro, Maria Rosaria; Offerta, Alessia; Crascì, Lucia; Micicchè, Lucia; Panico, Anna Maria; Bonina, Francesco; Puglisi, Giovanni

    2017-03-01

    Sesamol is a natural phenolic compound extracted from Sesamum indicum seed oil. Sesamol is endowed with several beneficial effects, but its use as a topical agent is strongly compromised by unfavorable chemical-physical properties. Therefore, to improve its characteristics, the aim of the present work was the formulation of nanostructured lipid carriers as drug delivery systems for topical administration of sesamol.Two different nanostructured lipid carrier systems have been produced based on the same solid lipid (Compritol® 888 ATO) but in a mixture with two different kinds of oil phase such as Miglyol® 812 (nanostructured lipid carrier-M) and sesame oil (nanostructured lipid carrier-PLUS). Morphology and dimensional distribution of nanostructured lipid carriers have been characterized by differential scanning calorimetry and photon correlation spectroscopy, respectively. The release pattern of sesamol from nanostructured lipid carriers was evaluated in vitro determining drug percutaneous absorption through excised human skin. Furthermore, an oxygen radical absorbance capacity assay was used to determine their antioxidant activity.From the results obtained, the method used to formulate nanostructured lipid carriers led to a homogeneous dispersion of particles in a nanometric range. Sesamol has been encapsulated efficiently in both nanostructured lipid carriers, with higher encapsulation efficiency values (> 90 %) when sesame oil was used as the oil phase (nanostructured lipid carrier-PLUS). In vitro evidences show that nanostructured lipid carrier dispersions were able to control the rate of sesamol diffusion through the skin, with respect to the reference formulations.Furthermore, the oxygen radical absorbance capacity assay pointed out an interesting and prolonged antioxidant activity of sesamol, especially when vehiculated by nanostructured lipid carrier-PLUS. Georg Thieme Verlag KG Stuttgart · New York.

  12. Comparison of airline passenger oxygen systems.

    PubMed

    Byrne, N J

    1995-08-01

    The principal sources of oxygen for inflight passenger use, scheduled and unscheduled, are examined. Present practices of assessment of the passenger's "fitness to fly" are described. Three partner airlines, British Airways, U.S. Air, and Qantas, catering for more than 8000 oxygen requests annually, are compared. Analysis of customer use suggests that medical oxygen requests are frequently not clinically justified. The growth in demand, for both scheduled and unscheduled use of an expensive resource, supports the need for a "recommended best practice" among carriers. Passengers with respiratory disorders who will most benefit from inflight oxygen are vulnerable either to hypoxia or asthma.

  13. Methodology for the assessment of oxygen as an energy carrier

    NASA Astrophysics Data System (ADS)

    Yang, Ming Wei

    Due to the energy intensity of the oxygen generating process, the electric power grid would benefit if the oxygen generating process was consumed electric power only during low demand periods. Thus, the question to be addressed in this study is whether oxygen production and/or usage can be modified to achieve energy storage and/or transmission objectives at lower cost. The specific benefit to grid would be a leveling, over time, of the demand profile and thus would require less installation capacity. In order to track the availability of electricity, a compressed air storage unit is installed between the cryogenic distillation section and the main air compressor of air separation unit. A profit maximizing scheme for sizing storage inventory and related equipments is developed. The optimum scheme is capable of market responsiveness. Profits of steel maker, oxy-combustion, and IGCC plants with storage facilities can be higher than those plants without storage facilities, especially, at high-price market. Price tracking feature of air storage integration will certainly increase profit margins of the plants. The integration may push oxy-combustion and integrated gasification combined cycle process into economic viability. Since oxygen is used in consumer sites, it may generate at remote locations and transport to the place needed. Energy losses and costs analysis of oxygen transportation is conducted for various applications. Energy consumptions of large capacity and long distance GOX and LOX pipelines are lower than small capacity pipelines. However, transportation losses and costs of GOX and LOX pipelines are still higher than electricity transmission.

  14. Bulk manufacture of concentrated oxygen gas-filled microparticles for intravenous oxygen delivery.

    PubMed

    Kheir, John N; Polizzotti, Brian D; Thomson, Lindsay M; O'Connell, Daniel W; Black, Katherine J; Lee, Robert W; Wilking, James N; Graham, Adam C; Bell, David C; McGowan, Francis X

    2013-08-01

    Self-assembling, concentrated, lipid-based oxygen microparticles (LOMs) have been developed to administer oxygen gas when injected intravenously, preventing organ injury and death from systemic hypoxemia in animal models. Distinct from blood substitutes, LOMs are a one-way oxygen carrier designed to rescue patients who experience life-threatening hypoxemia, as caused by airway obstruction or severe lung injury. Here, we describe methods to manufacture large quantities of LOMs using an in-line, recycling, high-shear homogenizer, which can create up to 4 liters of microparticle emulsion in 10 minutes, with particles containing a median diameter of 0.93 microns and 60 volume% of gas phase. Using this process, we screen 30 combinations of commonly used excipients for their ability to form stable LOMs. LOMs composed of DSPC and cholesterol in a 1:1 molar ratio are stable for a 100 day observation period, and the number of particles exceeding 10 microns in diameter does not increase over time. When mixed with blood in vitro, LOMs fully oxygenate blood within 3.95 seconds of contact, and do not cause hemolysis or complement activation. LOMs can be manufactured in bulk by high shear homogenization, and appear to have a stability and size profile which merit further testing. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Kinetic analysis of the interactions between calcium ferrite and coal char for chemical looping gasification applications: Identifying reduction routes and modes of oxygen transfer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riley, Jarrett; Siriwardane, Ranjani; Tian, Hanjing

    Chemical Looping Gasification (CLG) is an emerging technology that shows promise for efficient coal gasification by eliminating the need for energy intensive gas separations to achieve a non-nitrogen diluted syngas stream. Oxygen from oxygen carriers, such as CaFe 2O 4, are used for coal gasification in place of conventionally produced gaseous oxygen from cryogenic separation of air. These oxygen carriers are unique for their ability to selectively oxidize coal to form syngas and show limited reactivity with syngas components (H 2, CO). To gain a deeper understanding of how these unique oxygen carriers perform and to offer a first attemptmore » at the reaction modeling of solid mediated interactions of this nature, this study was carried out to determine the kinetic parameters associated with the selective oxidation of coal derived char (Wyodak and Illinois #6) with a metal ferrite, CaFe 2O 4. Using thermogravimetric analysis (TGA) coupled with mass spectrometry, the selective oxygen release of metal ferrite in the presence of char by proximal contact was examined. The application of combinatory model fitting approaches was used to describe controlling resistances during oxygen release. A combination of the modified shrinking core model (SCM) with planar oxygen ion diffusion control and reaction order based models was used for kinetic parameter determination. CaFe 2O 4 particle size plays a major role in the prevailing mode of oxygen release. Particle sizes on the order of 40–50 μm tend to favor first order kinetically controlled regimes independent of geometric and diffusion controls. The probability for oxygen ion diffusion controlling regimes increased when the particle size range of the oxygen carrier was increased up to 350 μm. Char type also impacted the prevalence of the controlling regime. Higher ranked chars react in a slower manner, limiting the gradient for oxygen ion release from the oxygen carrier. Activation energies determined for this process

  16. Kinetic analysis of the interactions between calcium ferrite and coal char for chemical looping gasification applications: Identifying reduction routes and modes of oxygen transfer

    DOE PAGES

    Riley, Jarrett; Siriwardane, Ranjani; Tian, Hanjing; ...

    2017-05-20

    Chemical Looping Gasification (CLG) is an emerging technology that shows promise for efficient coal gasification by eliminating the need for energy intensive gas separations to achieve a non-nitrogen diluted syngas stream. Oxygen from oxygen carriers, such as CaFe 2O 4, are used for coal gasification in place of conventionally produced gaseous oxygen from cryogenic separation of air. These oxygen carriers are unique for their ability to selectively oxidize coal to form syngas and show limited reactivity with syngas components (H 2, CO). To gain a deeper understanding of how these unique oxygen carriers perform and to offer a first attemptmore » at the reaction modeling of solid mediated interactions of this nature, this study was carried out to determine the kinetic parameters associated with the selective oxidation of coal derived char (Wyodak and Illinois #6) with a metal ferrite, CaFe 2O 4. Using thermogravimetric analysis (TGA) coupled with mass spectrometry, the selective oxygen release of metal ferrite in the presence of char by proximal contact was examined. The application of combinatory model fitting approaches was used to describe controlling resistances during oxygen release. A combination of the modified shrinking core model (SCM) with planar oxygen ion diffusion control and reaction order based models was used for kinetic parameter determination. CaFe 2O 4 particle size plays a major role in the prevailing mode of oxygen release. Particle sizes on the order of 40–50 μm tend to favor first order kinetically controlled regimes independent of geometric and diffusion controls. The probability for oxygen ion diffusion controlling regimes increased when the particle size range of the oxygen carrier was increased up to 350 μm. Char type also impacted the prevalence of the controlling regime. Higher ranked chars react in a slower manner, limiting the gradient for oxygen ion release from the oxygen carrier. Activation energies determined for this process

  17. Cobalt porphyrin-mediated oxygen transport in a polymer membrane. Effect of the cobalt porphyrin structure on the oxygen-binding reaction, oxygen-diffusion constants, and oxygen-transport efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nishide, Hiroyuki; Suzuki, Takayuki; Kawakami, Hiroyoshi

    1994-05-12

    New derivatives of (meso-[alpha],[alpha],[alpha],[alpha]-tetrakis(o-pivalamidophenyl)porphinato)cobalt (CoPs) were characterized by oxygen-binding equilibrium and rate constants of the cobalt centered in the porphyrins. They depended on the structure of the porphyrin; for example, the rate constants of oxygen binding and dissociation (k[sub on] and k[sub off]) for [alpha][sup 3][beta]-CoP[sub 4]P were 3 and 20 times as large as those for [alpha][sup 4]-CoB[sub 4]P, respectively. Oxygen transport through the polymer membranes containing CoPs as the fixed oxygen carriers was facilitated and was affected by the oxygen-binding character or the structure of CoPs. The logarithmically linear correlation of the oxygen-dissociation rate constant of CoPs (k[submore » off] = (3-66) x 10[sup 3] S[sup [minus]1]) with the diffusion constant of oxygen via CoPs fixed in the membranes (D[sub cc] = (3-140) x 10[sup [minus]9] cm[sup 2] s[sup [minus]1]) was given for those six CoP derivatives. 26 refs., 5 figs., 2 tabs.« less

  18. Oxygen "getter" effects on microstructure and carrier transport in low temperature combustion-processed a-InXZnO (X = Ga, Sc, Y, La) transistors.

    PubMed

    Hennek, Jonathan W; Smith, Jeremy; Yan, Aiming; Kim, Myung-Gil; Zhao, Wei; Dravid, Vinayak P; Facchetti, Antonio; Marks, Tobin J

    2013-07-24

    In oxide semiconductors, such as those based on indium zinc oxide (IXZO), a strong oxygen binding metal ion ("oxygen getter"), X, functions to control O vacancies and enhance lattice formation, hence tune carrier concentration and transport properties. Here we systematically study, in the IXZO series, the role of X = Ga(3+) versus the progression X = Sc(3+) → Y(3+) → La(3+), having similar chemical characteristics but increasing ionic radii. IXZO films are prepared from solution over broad composition ranges for the first time via low-temperature combustion synthesis. The films are characterized via thermal analysis of the precursor solutions, grazing incidence angle X-ray diffraction (GIAXRD), atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and scanning transmission electron microscopy (STEM) with high angle annular dark field (HAADF) imaging. Excellent thin-film transistor (TFT) performance is achieved for all X, with optimal compositions after 300 °C processing exhibiting electron mobilities of 5.4, 2.6, 2.4, and 1.8 cm(2) V(-1) s(-1) for Ga(3+), Sc(3+), Y(3+), and La(3+), respectively, and with I(on)/I(off) = 10(7)-10(8). Analysis of the IXZO TFT positive bias stress response shows X = Ga(3+) to be superior with mobilities (μ) retaining >95% of the prestress values and threshold voltage shifts (ΔV(T)) of <1.6 V, versus <85% μ retention and ΔV(T) ≈ 20 V for the other trivalent ions. Detailed microstructural analysis indicates that Ga(3+) most effectively promotes oxide lattice formation. We conclude that the metal oxide lattice formation enthalpy (ΔH(L)) and metal ionic radius are the best predictors of IXZO oxygen getter efficacy.

  19. Red blood cell distribution width and haemoglobin are associated with hospital admission in patients with acute allergic reactions.

    PubMed

    Lippi, Giuseppe; Buonocore, Ruggero; Picanza, Alessandra; Schirosa, Fabio; Cervellin, Gianfranco

    2016-01-01

    Red blood cell distribution width (RDW) is significantly associated with a variety of human disorders. This study aimed to investigate whether RDW value at admission may predict the need of hospitalisation in patients presenting to the emergency department (ED) with acute allergic reactions. The study population consisted of adult patients (aged > 17) admitted to the ED for acute allergic reactions. One hundred and thirty-two subjects were included, 12 of whom (9%) required hospital admission for severity of symptoms. Patients who needed hospital admission displayed significantly lower values of haemoglobin and significantly higher values of RDW-coefficient of variation (RDW-CV). In multivariate analysis, haemoglobin and RDW-CV were found to be independent predictors of hospital admission. The area under the curve (AUC), sensitivity and specificity for predicting hospital admission were 0.72, 0.88 and 0.42 for haemoglobin and 0.73, 0.88 and 0.50 for RDW-CV, respectively. The combination of these tests (both positive) was characterised by 0.76 AUC, 0.83 sensitivity, 0.67 specificity, 0.96 negative predictive value and 0.30 positive predictive. The results of this study suggest that two common and inexpensive parameters such as haemoglobin and RDW are independent predictors of hospital admission in patients presenting to the ED with acute allergic reactions.

  20. Image-based modelling of skeletal muscle oxygenation

    PubMed Central

    Clough, G. F.

    2017-01-01

    The supply of oxygen in sufficient quantity is vital for the correct functioning of all organs in the human body, in particular for skeletal muscle during exercise. Disease is often associated with both an inhibition of the microvascular supply capability and is thought to relate to changes in the structure of blood vessel networks. Different methods exist to investigate the influence of the microvascular structure on tissue oxygenation, varying over a range of application areas, i.e. biological in vivo and in vitro experiments, imaging and mathematical modelling. Ideally, all of these methods should be combined within the same framework in order to fully understand the processes involved. This review discusses the mathematical models of skeletal muscle oxygenation currently available that are based upon images taken of the muscle microvasculature in vivo and ex vivo. Imaging systems suitable for capturing the blood vessel networks are discussed and respective contrasting methods presented. The review further informs the association between anatomical characteristics in health and disease. With this review we give the reader a tool to understand and establish the workflow of developing an image-based model of skeletal muscle oxygenation. Finally, we give an outlook for improvements needed for measurements and imaging techniques to adequately investigate the microvascular capability for oxygen exchange. PMID:28202595

  1. Blind identification of the number of sub-carriers for orthogonal frequency division multiplexing-based elastic optical networking

    NASA Astrophysics Data System (ADS)

    Zhao, Lei; Xu, Hengying; Bai, Chenglin

    2018-03-01

    In orthogonal frequency division multiplexing (OFDM)-based elastic optical networking (EON), it is imperative to identify unknown parameters of OFDM-based EON signals quickly, intelligently and robustly. Because the number of sub-carriers determines the size of the sub-carriers spacing and then affects the symbol period of the OFDM and the anti-dispersion capability of the system, the identification of the number of sub-carriers has a profound effect on the identification of other key parameters of the system. In this paper, we proposed a method of number identification for sub-carriers of OFDM-based EON signals with help of high-order cyclic cumulant. The specific fourth-order cyclic cumulant exists only at the location of its sub-carriers frequencies. So the identification of the number of sub-carriers can be implemented by detecting the cyclic-frequencies. The proposed scheme in our study can be divided into three sub-stages, i.e. estimating the spectral range, calculating the high-order cyclic cumulant and identifying the number of sub-carriers. When the optical signal-to-noise ratios (OSNR) varied from 16dB to 22dB, the number of sub-carriers (64-512) was successfully identified in the experiment, and from the statistical point of view, the average identification absolute accuracy (IAAs) exceeded 94%.

  2. Magnetism and Metal-Insulator Transition in Oxygen Deficient SrTiO 3

    DOE PAGES

    Lopez-Bezanilla, Alejandro; Ganesh, Panchapakesan; Littlewood, Peter B.

    2015-09-08

    First-principles calculations to study the electronic and magnetic properties of bulk, oxygen-deficient SrTiO 3 (STO) under different doping conditions and densities have been conducted. The appearance of magnetism in oxygen-deficient STO is not determined solely by the presence of a single oxygen vacancy but by the density of free carriers and the relative proximity of the vacant sites. We find that while an isolated vacancy behaves as a nonmagnetic double donor, manipulation of the doping conditions allows the stability of a single-donor state, with emergent local moments coupled ferromagnetically by carriers in the conduction band. Strong local lattice distortions enhancemore » the binding of this state. As a result, the energy of the in-gap local moment can be further tuned by orthorhombic strain. Consequently we find that the free-carrier density and strain are fundamental components to obtaining trapped spin-polarized electrons in oxygen-deficient STO, which may have important implications in the design of optical devices.« less

  3. Knowledge of sickle cell disease and haemoglobin electrophoresis: a survey of students of a tertiary institution.

    PubMed

    Alao, O O; Araoye, M; Ojabo, C

    2009-01-01

    Sickle Cell Disease (SCD) is the commonest genetic disease worldwide. Of the sickle cell control strategies, premarital genetic counselling is increasingly practised in many countries of the world. Knowledge of the citizenry of a nation about SCD constitutes an important variable that influences the acceptability, practice and success of premarital genetic counselling. A study of students of Benue State University, Makurdi was carried out to determine their current level of knowledge. A cross sectional study involving 300 students of Benue State University, Makurdi; selected by a multistage stratified sampling technique, using self administered structured questionnaire, was carried out. Virtually all study respondents had at one time or the other heard about sickle cell disease. Based on the criteria used for knowledge scoring, less than half of the students (48%) demonstrated good knowledge. Overall Mean Score Knowledge (MSK) was 4.65 +/- 1.65. MSK was 4.58 +/- 1.66 and 4.74 +/- 1.64 for males and females respectively; there was no statistically significant difference (P > 0.05). However, having an affected relative suffering from sickle cell disease significantly influenced level of knowledge among study respondents (P < 0.05), but was not significantly associated with respondents knowing their haemoglobin phenotype. Only 141 students (47%) knew their haemoglobin phenotype. Level of knowledge about SCD did not significantly increase with age. Also, sex and religion did not significantly influence level of knowledge. The knowledge about SCD was poor and only a few knew their haemoglobin phenotype. If sickle cell disease control strategies must yield any significant results, more education about SCD, especially among students in tertiary institutions in Nigeria is recommended. The use of persons with SCD as peer educators/counsellors should be explored.

  4. Haemoglobin status of adult women of two ethnic groups living in a peri-urban area of Kolkata city, India: a micro-level study.

    PubMed

    Ghosh, Rohini; Bharati, Premananda

    2003-01-01

    A micro level study on the haemoglobin status of 127 Munda (a tribe) and 174 Poundrakshatriya (Pod) (caste) women were conducted in the peri-urban area of Kolkata City, India. The two ethnic groups were selected in order to find out whether populations residing in the same habitat, with similar medical and health care facilities have similar haemoglobin status. Results indicate that there exists very high percentage of anaemia in both the ethnic groups and 100 percent anaemia was observed among the Munda. Mean haemoglobin level was higher among the women of both the ethnic groups, consuming calorie, protein, iron and folic acid, above the recommended value (Indian Council of Medical Research, 2000). Women below the age of 30 years were found to be more anaemic. Education (P <0.001), height (P <0.001) and weight (P<0.005) were significantly associated with the haemoglobin status of the Pod women. Haemoglobin level of both ethnic groups was found to increase with increase in Body Mass Index. Low socioeconomic condition, very low literacy rates, poverty and higher live births may have lowered the haemoglobin level of the women of the Munda population. However, women of both the ethnic groups were found to be anaemic in higher percentage than the state of West Bengal and all India (NFHS, 2000). Linear regression analysis indicated that expenditure on food had positive effect on the haemoglobin level (P<0.05) of the Munda adult women, possibly due to better buying capacity. However, negative effect of food expenditure on the haemoglobin level was noticed among the Pod women (P<0.05), which may be due to disparity in food sharing within the households. Thus populations residing with similar medical and health care facilities revealed differences in the haemoglobin level. Differential expenditure pattern and food sharing practice seems to be the major factors responsible for the differences in haemoglobin status among the adult women in this present study. Very low intake

  5. Erythroid differentiation ability of butyric acid analogues: identification of basal chemical structures of new inducers of foetal haemoglobin.

    PubMed

    Bianchi, Nicoletta; Chiarabelli, Cristiano; Zuccato, Cristina; Lampronti, Ilaria; Borgatti, Monica; Amari, Gabriele; Delcanale, Maurizio; Chiavilli, Francesco; Prus, Eugenia; Fibach, Eitan; Gambari, Roberto

    2015-04-05

    Several investigations have demonstrated a mild clinical status in patients with β-globin disorders and congenital high persistence of foetal haemoglobin. This can be mimicked by a pharmacological increase of foetal γ-globin genes expression and foetal haemoglobin production. Our goal was to apply a multistep assay including few screening methods (benzidine staining, RT-PCR and HPLC analyses) and erythroid cellular model systems (the K562 cell line and erythroid precursors collected from peripheral blood) to select erythroid differentiation agents with foetal haemoglobin inducing potential. With this methodology, we have identified a butyric acid derivative, namely the 4174 cyclopropanecarboxylic acid compound, able to induce erythroid differentiation without antiproliferative effect in K562 cells and increase of γ-globin gene expression in erythroid precursor cells. The results are relevant for pharmacological treatments of haemoglobinopathies, including β-thalassaemia and sickle cell anaemia. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Carrier-interleaved orthogonal multi-electrode multi-carrier resistivity-measurement tool

    NASA Astrophysics Data System (ADS)

    Cai, Yu; Sha, Shuang

    2016-09-01

    This paper proposes a new carrier-interleaved orthogonal multi-electrode multi-carrier resistivity-measurement tool used in a cylindrical borehole environment during oil-based mud drilling processes. The new tool is an orthogonal frequency division multiplexing access-based contactless multi-measurand detection tool. The tool can measure formation resistivity in different azimuthal angles and elevational depths. It can measure many more measurands simultaneously in a specified bandwidth than the legacy frequency division multiplexing multi-measurand tool without a channel-select filter while avoiding inter-carrier interference. The paper also shows that formation resistivity is not sensitive to frequency in certain frequency bands. The average resistivity collected from N subcarriers can increase the measurement of the signal-to-noise ratio (SNR) by N times given no amplitude clipping in the current-injection electrode. If the clipping limit is taken into account, with the phase rotation of each single carrier, the amplitude peak-to-average ratio can be reduced by 3 times, and the SNR can achieve a 9/N times gain over the single-carrier system. The carrier-interleaving technique is also introduced to counter the carrier frequency offset (CFO) effect, where the CFO will cause inter-pad interference. A qualitative analysis and simulations demonstrate that block-interleaving performs better than tone-interleaving when coping with a large CFO. The theoretical analysis also suggests that increasing the subcarrier number can increase the measurement speed or enhance elevational resolution without sacrificing receiver performance. The complex orthogonal multi-pad multi-carrier resistivity logging tool, in which all subcarriers are complex signals, can provide a larger available subcarrier pool than other types of transceivers.

  7. Deworming drugs for soil-transmitted intestinal worms in children: effects on nutritional indicators, haemoglobin and school performance.

    PubMed

    Taylor-Robinson, David C; Maayan, Nicola; Soares-Weiser, Karla; Donegan, Sarah; Garner, Paul

    2012-07-11

    The World Health Organization (WHO) recommends treating all school children at regular intervals with deworming drugs in areas where helminth infection is common. The WHO state this will improve nutritional status, haemoglobin, and cognition and thus will improve health, intellect, and school attendance. Consequently, it is claimed that school performance will improve, child mortality will decline, and economic productivity will increase. Given the important health and societal benefits attributed to this intervention, we sought to determine whether they are based on reliable evidence. To summarize the effects of giving deworming drugs to children to treat soil-transmitted intestinal worms (nematode geohelminths) on weight, haemoglobin, and cognition; and the evidence of impact on physical well being, school attendance, school performance, and mortality. In February 2012, we searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, EMBASE, LILACS, mRCT, and reference lists, and registers of ongoing and completed trials. We selected randomized controlled trials (RCTs) and quasi-RCTs comparing deworming drugs for geohelminth worms with placebo or no treatment in children aged 16 years or less, reporting on weight, haemoglobin, and formal test of intellectual development. In cluster-RCTs treating communities or schools, we also sought data on school attendance, school performance, and mortality. We included trials that included health education with deworming. At least two authors independently assessed the trials, evaluated risk of bias, and extracted data. Continuous data were analysed using the mean difference (MD) with 95% confidence intervals (CI). Where data were missing, we contacted trial authors. We used GRADE to assess evidence quality, and this is reflected in the wording we used: high quality ("deworming improves...."); moderate quality ("deworming probably improves..."); low quality ("deworming may improve...."); and very low quality

  8. Injection deep level transient spectroscopy: An improved method for measuring capture rates of hot carriers in semiconductors

    DOE PAGES

    Fleming, R. M.; Seager, C. H.; Lang, D. V.; ...

    2015-07-02

    In this study, an improved method for measuring the cross sections for carrier trapping at defects in semiconductors is described. This method, a variation of deep level transient spectroscopy(DLTS) used with bipolar transistors, is applied to hot carrier trapping at vacancy-oxygen, carbon-oxygen, and three charge states of divacancy centers (V 2) in n- and p-type silicon. Unlike standard DLTS, we fill traps by injecting carriers into the depletion region of a bipolar transistor diode using a pulse of forward bias current applied to the adjacent diode. We show that this technique is capable of accurately measuring a wide range ofmore » capture cross sections at varying electric fields due to the control of the carrier density it provides. Because this technique can be applied to a variety of carrier energy distributions, it should be valuable in modeling the effect of radiation-induced generation-recombination currents in bipolar devices.« less

  9. Haemoglobin J-Baltimore can be detected by HbA1c electropherogram but with underestimated HbA1c value.

    PubMed

    Brunel, Valéry; Lahary, Agnčs; Chagraoui, Abdeslam; Thuillez, Christian

    2016-01-01

    Glycated haemoglobin (HbA(1c)) is considered the gold standard for assessing diabetes compensation and treatment. In addition, fortuitous detection of haemoglobin variants during HbA1c measurement is not rare. Recently, two publications reported different conclusions on accuracy of HbA(1c) value using capillary electrophoresis method in presence of haemoglobin J-Baltimore (HbJ).
Here we describe the fortuitous detection of unknown HbJ using capillary electrophoresis for measurement of HbA(1c). A patient followed for gestational diabetes in our laboratory presented unknown haemoglobin on Capillarys 2 Flex Piercing analyser which was identified as HbJ. HbJ is not associated with haematological abnormalities. High Performance Liquid Chromatography methods are known to possibly underestimate HbA(1c) value in the presence of this variant. This variant and its glycated form are clearly distinguished on electropherogram but HbJ was responsible for underestimating the true area of HbA(1c).
 Capillary electrophoresis is a good method for detecting HbJ but does not seem suitable for evaluation of HbA(1C) value in patients in presence of HbJ variant.

  10. Stable wafer-carrier system

    DOEpatents

    Rozenzon, Yan; Trujillo, Robert T; Beese, Steven C

    2013-10-22

    One embodiment of the present invention provides a wafer-carrier system used in a deposition chamber for carrying wafers. The wafer-carrier system includes a base susceptor and a top susceptor nested inside the base susceptor with its wafer-mounting side facing the base susceptor's wafer-mounting side, thereby forming a substantially enclosed narrow channel. The base susceptor provides an upward support to the top susceptor.

  11. Effect of Anesthesia Carrier Gas on In-Vivo Circulation Times of Ultrasound Microbubble Contrast Agents in Rats

    PubMed Central

    Mullin, Lee; Gessner, Ryan; Kwan, James; Kaya, Mehmet; Borden, Mark A.; Dayton, Paul A.

    2012-01-01

    Purpose Microbubble contrast agents are currently implemented in a variety of both clinical and preclinical ultrasound imaging studies. The therapeutic and diagnostic capabilities of these contrast agents are limited by their short in-vivo lifetimes, and research to lengthen their circulation times is ongoing. In this manuscript, observations are presented from a controlled experiment performed to evaluate differences in circulation times for lipid shelled perfluorocarbon-filled contrast agents circulating within rodents as a function of inhaled anesthesia carrier gas. Methods The effects of two common anesthesia carrier gas selections - pure oxygen and medical air – were observed within five rats. Contrast agent persistence within the kidney was measured and compared for oxygen and air anesthesia carrier gas for six bolus contrast injections in each animal. Simulations were performed to examine microbubble behavior with changes in external environment gases. Results A statistically significant extension of contrast circulation time was observed for animals breathing medical air compared to breathing pure oxygen. Simulations support experimental observations and indicate that enhanced contrast persistence may be explained by reduced ventilation/perfusion mismatch and classical diffusion, in which nitrogen plays a key role by contributing to the volume and diluting other gas species in the microbubble gas core. Conclusion: Using medical air in place of oxygen as the carrier gas for isoflurane anesthesia can increase the circulation lifetime of ultrasound microbubble contrast agents. PMID:21246710

  12. Oxygen absorption by skin exposed to oxygen supersaturated water.

    PubMed

    Reading, Stacey A; Yeomans, Maggie

    2012-05-01

    The present study tests the hypothesis that skin on the plantar surface of the foot absorbs oxygen (O(2)) when immersed in water that has a high dissolved O(2) content. Healthy male and female subjects (24.2 ± 1.4 years) soaked each foot in tap water (1.7 ± 0.1 mg O(2)·L(-1); 30.7 ± 0.3 °C) or O(2)-infused water (50.2 ± 1.7 mg O(2)·L(-1); 32.1 ± 0.5 °C) for up to 30 min in 50 different experiments. Transcutaneous oximetry and near infrared spectroscopy were used to evaluate changes in skin PO(2), oxygenated haemoglobin, and cytochrome oxidase aa(3) that resulted from treatment. Compared with the tap water condition, tissue oxygenation index was 3.5% ± 1.3% higher in feet treated for 30 min with O(2)-infused water. This effect persisted after treatment, as skin PO(2) was higher in feet treated with O(2)-infused water at 2 min (237 ± 9 vs. 112 ± 5 mm HG) and 15 min (131 ± 1 vs. 87 ± 4 mm HG) post-treatment. When blood flow to the foot was occluded for 5 min, feet resting in O(2)-infused water maintained a 3-fold higher O(2) consumption rate than feet treated with tap water (9.1 ± 1.4 vs. 3.0 ± 1.0 µL·100 g(-1)·min(-1)). We estimate that skin absorbs 4.5 mL of O(2)·m(-2)·min(-1) from O(2)-infused water. Thus, skin absorbs appreciable amounts of O(2) from O(2)-infused water. This finding may prove useful and assist development of treatments targeting skin diseases with ischemic origin.

  13. Effects of a diphenyl-ether herbicide, oxyfluorfen, on human BFU-E/CFU-E development and haemoglobin synthesis.

    PubMed

    Rio, B; Parent-Massin, D; Lautraite, S; Hoellinger, H

    1997-02-01

    The diphenyl-ether herbicides exert their phytotoxic activity by preventing chlorophyll formation in plants as a result of inhibition of protoporphyrinogen oxidase. This enzyme is the last step of the common pathway for chlorophyll and haem biosynthesis. The aim of this work is to determine whether herbicide inhibitors of plant protoporphyrinogen oxidase could act on the human protoporphyrinogen oxidase involved in haemoglobin synthesis and cause heamatologic diseases. Human erythroblastic progenitors (BFU-E/CFU-E: Burst Forming Unit-Erythroid and Colony Forming Unit-Erythroid) were exposed to oxyfluorfen, a diphenyl-ether herbicide in the presence of erythropoietin, and the haematoxicity evaluated in vitro by scoring the development of BFU-E/CFU-E colonies after 7 and 14 days of culture. The toxic effect on differentiation has been evaluated using four criteria: morphology, total protein, total porphyrin, and haemoglobin content. The study of BFU-E/CFU-E proliferation and differentiation showed a cytotoxic effect of oxyfluorfen only at very high concentrations. In contrast, haemoglobin synthesis can be inhibited by concentration of oxyfluorfen (10(-4) M) that have no adverse effect on cellular proliferation.

  14. Electrochemical behavior of negative electrode of lead-acid cells based on reticulated vitreous carbon carrier

    NASA Astrophysics Data System (ADS)

    Czerwiński, A.; Obrębowski, S.; Kotowski, J.; Rogulski, Z.; Skowroński, J. M.; Krawczyk, P.; Rozmanowski, T.; Bajsert, M.; Przystałowski, M.; Buczkowska-Biniecka, M.; Jankowska, E.; Baraniak, M.

    Reticulated vitreous carbon (RVC ®) and RVC ® plated with lead were investigated as carriers for the negative electrode of lead-acid cell. The RVC ® and Pb/RVC ® carriers were pasted with active paste (received from JENOX Ltd., Polish producer of lead-acid batteries) and prepared to be used in lead-acid cell. Comparative study of electrodes based on RVC ® and Pb/RVC ® has been done using constant-current charging/discharging, constant-potential discharging and cycling voltammetry measurements. Scanning electron microscopy (SEM) was employed to determine the morphology of the lead layer deposited on the RVC surface. Hybrid flooded single lead-acid cells containing one negative electrode, based on new type of carrier (RVC ® or Pb/RVC ®), sandwiched between two positive electrodes, based on the Pb-Ca grids, were assembled and subjected to electrochemical tests. It has been found that both materials, RVC ® and Pb/RVC ®, can be used as carriers of negative electrode, but the latter seems to have better influence on the discharge performance.

  15. The Secretion of Oxygen into the Swim-bladder of Fish

    PubMed Central

    Wittenberg, Jonathan B.; Wittenberg, Beatrice A.

    1961-01-01

    Toadfish, Opsanus tau, L., were maintained in sea water equilibrated with gas mixtures containing a fixed proportion of oxygen and varying proportions of carbon monoxide. The swim-bladder was emptied by puncture, and, after an interval of 24 or 48 hours, the newly secreted gases were withdrawn and analyzed. Both carbon monoxide and oxygen are accumulated in the swim-bladder at tensions greater than ambient. The ratio of concentrations, carbon monoxide (secreted): carbon monoxide (administered) bears a constant relation to the ratio, oxygen (secreted): oxygen (administered). The value of the partition coefficient describing this relation is (α = 5.44). The two gases are considered to compete for a common intracellular carrier mediating their active transport. The suggestion is advanced that the intracellular oxygen carrier is a hemoglobin. Comparison of the proportions of carboxy- and oxyhemoglobin in the blood with the composition of the secreted gas proves that the secreted gases are not evolved directly from combination with blood hemoglobin. The suggestion is advanced that cellular oxygen secretion occurs in the rete mirabile: the rete may build up large oxygen tensions in the gas gland capillaries. It is suggested that the gas gland acts as a valve impeding back diffusion of gases from the swim-bladder. PMID:13786093

  16. Embryogenesis and oxygen consumption in benthic egg clutches of a tropical clownfish, Amphiprion melanopus (Pomacentridae).

    PubMed

    Green, Bridget S

    2004-05-01

    Variation in size at hatching is common in demersal spawning organisms, suggesting that processes during embryonic development may be critical in determining growth and development. To examine critical periods during embryonic development in the demersal spawning reef fish Amphiprion melanopus, the rate of oxygen consumption within an egg clutch was compared to morphological changes in the embryos. Oxygen consumption was least on day 1 of development where organ differentiation had not begun (mean 1.73+/-0.34x10(-5) micromol O(2) egg(-1) s(-1)). Tail movement throughout the perivitelline fluid began on day 3 and is likely to assist in moving oxygen around the embryo, complementing diffusive transport. The appearance of haemoglobin in the blood corresponded to a peak in oxygen consumption on day 4, where the highest mean rate of oxygen consumption was recorded (6.73+/-0.82x10(-5) micromol O(2) egg(-1) s(-1)). This could be a critical period in development whereby risk of mortality is increased through increased embryo requirements at developmental thresholds.

  17. Realization of LOS (Line of Sight) stabilization based on reflector using carrier attitude compensation method

    NASA Astrophysics Data System (ADS)

    Mao, Yao; Tian, Jing; Ma, Jia-guang

    2015-02-01

    The techonology of LOS stabilization is widely applicated in moving carrier photoelectric systems such as shipborne, airborne and so on. In application situations with compact structure, such as LOS stabilization system of unmanned aerial vehicle, LOS stabilization based on reflector is adopted, and the detector is installed on the carrier to reduce the volume of stabilized platform and loading weight. However, the LOS deflection angle through reflector and the rotation angle of the reflector has a ratio relation of 2:1, simple reflector of stable inertial space can not make the optical axis stable. To eliminate the limitation of mirror stabilizing method, this article puts forward the carrier attitude compensation method, which uses the inertial sensor installed on the carrier to measure the attitude change of the carrier, and the stabilized platform rotating half of the carrier turbulence angle to realize the LOS stabilization.

  18. Artefactually low glycated haemoglobin in a patient with severe hypertriglyceridaemia

    PubMed Central

    Garrib, A; Griffiths, W; Eldridge, P; Hatton, R; Worsley, A; Crook, M

    2003-01-01

    This report describes a case of artefactually low glycated haemoglobin (Hb) in a patient with type II diabetes and severe hypertriglyceridaemia. The effect of hypertriglyceridaemia on glycated Hb determination using the Abbott Vision method was investigated in a series of patients with diabetes. The interference of triglycerides in glycated Hb assays was also investigated by two other methods, the Beckman Synchron CX4 delta immunoturbidimetric method, and the Primus affinity chromatography high performance liquid chromatography assay. PMID:12719463

  19. Carrier screening for single gene disorders.

    PubMed

    Rose, Nancy C; Wick, Myra

    2018-04-01

    Screening for genetic disorders began in 1963 with the initiation of newborn screening for phenylketonuria. Advances in molecular technology have made both newborn screening for newborns affected with serious disorders, and carrier screening of individuals at risk for offspring with genetic disorders, more complex and more widely available. Carrier screening today can be performed secondary to family history-based screening, ethnic-based screening, and expanded carrier screening (ECS). ECS is panel-based screening, which analyzes carrier status for hundreds of genetic disorders irrespective of patient race or ethnicity. In this article, we review the historical and current aspects of carrier screening for single gene disorders, including future research directions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Nanofiber Based Optical Sensors for Oxygen Determination

    NASA Astrophysics Data System (ADS)

    Xue, Ruipeng

    Oxygen sensors based on luminescent quenching of nanofibers were developed for measurement of both gaseous and dissolved oxygen concentrations. Electrospinning was used to fabricate "core-shell" fiber configurations in which oxygen-sensitive transition metal complexes are embedded into a polymer 'core' while a synthetic biocompatible polymer provides a protective 'shell.' Various matrix polymers and luminescent probes were studied in terms of their sensitivity, linear calibration, reversibility, response time, stability and probe-matrix interactions. Due to the small size and high surface area of these nanofibers, all samples showed rapid response and a highly linear response to oxygen. The sensitivity and photostability of the sensors were controlled by the identity of both the probe molecule and the polymer matrix. Such nanofiber sensor forms are particularly suitable in biological applications due to the fact that they do not consume oxygen, are biocompatible and biomimetic and can be easily incorporated into cell culture. Applications of these fibers in cancer cell research, wound healing, breath analysis and waste water treatment were explored.

  1. Comparison of the MBBR denitrification carriers for advanced nitrogen removal of wastewater treatment plant effluent.

    PubMed

    Yuan, Quan; Wang, Haiyan; Hang, Qianyu; Deng, Yangfan; Liu, Kai; Li, Chunmei; Zheng, Shengzhi

    2015-09-01

    The moving bed biofilm reactors (MBBRs) were used to remove the residual NO3(-)-N of wastewater treatment plant (WWTP) effluent, and the MBBR carriers for denitrification were compared. The results showed that high denitrification efficiency can be achieved with polyethylene, polypropylene, polyurethane foam, and haydite carriers under following conditions: 7.2 to 8.0 pH, 24 to 26 °C temperature, 12 h hydraulic retention time (HRT), and 25.5 mg L(-1) external methanol dosage, while the WWTP effluent total nitrogen (TN) was between 2.6 and 15.4 mg L(-1) and NO3(-)-N was between 0.2 and 12.6 mg L(-1). The MBBR filled with polyethylene carriers had higher TN and NO3(-)-N removal rate (44.9 ± 19.1 and 83.4 ± 13.0%, respectively) than those with other carriers. The minimum effluent TN and NO3(-)-N of polyethylene MBBR were 1.6 and 0.1 mg L(-1), respectively, and the maximum denitrification rate reached 23.0 g m(-2) day(-1). When chemical oxygen demand (COD)/TN ratio dropped from 6 to 4, the NO3(-)- N and TN removal efficiency decreased significantly in all reactors except for that filled with polyethylene, which indicated that the polyethylene MBBR can resist influent fluctuation much better. The three-dimensional excitation-emission matrix analysis showed that all the influent and effluent of MBBRs contain soluble microbial products (SMPs)-like organics and biochemical oxygen demand (BOD), which can be removed better by MBBRs filled with haydite and polyethylene carriers. The nitrous oxide reductase (nosZ)-based terminal restriction fragment length polymorphism (T-RFLP) analysis suggested that the dominant bacteria in polyethylene MBBR are the key denitrificans.

  2. Effects of Rambutan Peel Extract to The Number of Erythrocytes and Haemoglobin in Rats Exposed to Cigarette Smoke

    NASA Astrophysics Data System (ADS)

    Lisdiana; Dewi, F. K.

    2017-04-01

    Cigarette smoke is one of the exogenous free radicals sources. When it is inhaled, its activity may damage the structure of erythrocyte membrane function. The impacts of free radicals can be reduced through the provision of antioxidants. Rambutan fruit peel contains the phenolic compound in the form of polyphenols that are antioxidants. The purpose of this study is to determine the effect of rambutan fruit peel extracts to the number of erythrocytes and haemoglobin in rats exposed to cigarette smoke. This design used Post Test Control Group Design. A sample of 25 rats was divided into five groups, each group consisting of 5 rats. The positive control group (K+) were given a standard food and drinking water. The negative control group (K) by three cigarettes, the treatment group (KP1, KP2, KP3) by three cigarettes and skin extract of rambutan each treatment group with a dose 15 mg/kg, 30 mg/kg and 45 mg/kg for 30 days. Data on the number of erythrocytes and haemoglobin in rat blood was analysed with LSD and to determine the optimum dosage was analysed by using regression test. Research results shown that the content of rambutan fruit peel extract may increase the number of erythrocytes and haemoglobin of blood. Conclusions from this research are the rambutan fruit peel extract at a dose of 45 mg/kg body weight can increase and maintain the number of erythrocytes and haemoglobin in the blood of rat exposed to cigarette smoke.

  3. Determine the optimal carrier selection for a logistics network based on multi-commodity reliability criterion

    NASA Astrophysics Data System (ADS)

    Lin, Yi-Kuei; Yeh, Cheng-Ta

    2013-05-01

    From the perspective of supply chain management, the selected carrier plays an important role in freight delivery. This article proposes a new criterion of multi-commodity reliability and optimises the carrier selection based on such a criterion for logistics networks with routes and nodes, over which multiple commodities are delivered. Carrier selection concerns the selection of exactly one carrier to deliver freight on each route. The capacity of each carrier has several available values associated with a probability distribution, since some of a carrier's capacity may be reserved for various orders. Therefore, the logistics network, given any carrier selection, is a multi-commodity multi-state logistics network. Multi-commodity reliability is defined as a probability that the logistics network can satisfy a customer's demand for various commodities, and is a performance indicator for freight delivery. To solve this problem, this study proposes an optimisation algorithm that integrates genetic algorithm, minimal paths and Recursive Sum of Disjoint Products. A practical example in which multi-sized LCD monitors are delivered from China to Germany is considered to illustrate the solution procedure.

  4. Structural vs. intrinsic carriers: contrasting effects of cation chemistry and disorder on ionic conductivity in pyrochlores

    DOE PAGES

    Perriot, Romain; Uberuaga, Blas P.

    2015-04-21

    We use molecular dynamics simulations to investigate the role of cation disorder on oxygen diffusion in Gd 2Zr 2O 7 (GZO) and Gd 2Ti 2O 7 (GTO) pyrochlores, a class of complex oxides which contain a structural vacancy relative to the basic fluorite structure. The introduction of disorder has distinct effects depending on the chemistry of the material, increasing the mobility of structural carriers by up to four orders of magnitude in GZO. In contrast, in GTO, there is no mobility at zero or low disorder on the ns timescale, but higher disorder liberates the otherwise immobile carriers, allowing diffusionmore » with rates comparable to GZO for the fully disordered material. Here, we show that the cation disorder enhances the diffusivity by both increasing the concentration of mobile structural carriers and their individual mobility. The disorder also influences the diffusion in materials containing intrinsic carriers, such as additional vacancies VO or oxygen interstitials OI. And while in ordered GZO and GTO the contribution of the intrinsic carriers dominates the overall diffusion of oxygen, OI in GZO contributes along with structural carriers, and the total diffusion rate can be calculated by assuming simple additive contributions from the two sources. Although the disorder in the materials with intrinsic defects usually enhances the diffusivity as in the defect-free case, in low concentrations, cation antisites AB or BA, where A = Gd and B = Zr or Ti, can act as traps for fast intrinsic defects. The trapping results in a lowering of the diffusivity, and causes a non-monotonic behavior of the diffusivity with disorder. Conversely, in the case of slow intrinsic defects, the main effect of the disorder is to liberate the structural carriers, resulting in an increase of the diffusivity regardless of the defect trapping.« less

  5. The effects of residual pump blood on patient plasma free haemoglobin levels post cardiac surgery.

    PubMed

    Schotola, H; Wetz, A J; Popov, A F; Bergmann, I; Danner, B C; Schöndube, F A; Bauer, M; Bräuer, A

    2016-09-01

    At the end of cardiopulmonary bypass, there are invariably several hundred millilitres of residual pump blood in the reservoir, which can either be re-transfused or discarded. The objective of this prospective observational study was to investigate the quality of the residual pump blood, focusing on plasma free haemoglobin (pfHb) and blood cell counts. Fifty-one consecutive patients were included in the study. Forty-nine units of residual pump blood and 58 units of transfused red blood cell (RBC) concentrates were analysed. The mean preoperative pfHb of the patients was 0.057 ± 0.062 g/l, which increased gradually to 0.55 ± 0.36 g/l on arrival in the intensive care unit postoperatively. On the first postoperative day, the mean pfHb had returned to within the normal range. Our data showed that haemoglobin, haematocrit, and erythrocyte counts of residual pump blood were approximately 40% of the values in standardised RBC concentrates. Plasma free haemoglobin was significantly higher in residual pump blood compared to RBC concentrates, and nearly twice as high as the pfHb in patient blood samples taken contemporaneously. Our findings indicate that residual pump blood pfHb levels are markedly higher compared to patients' blood and RBC concentrates, but that its administration does not significantly increase patients' pfHb levels.

  6. Deworming drugs for soil-transmitted intestinal worms in children: effects on nutritional indicators, haemoglobin and school performance.

    PubMed

    Taylor-Robinson, David C; Maayan, Nicola; Soares-Weiser, Karla; Donegan, Sarah; Garner, Paul

    2012-11-14

    The World Health Organization (WHO) recommends treating all school children at regular intervals with deworming drugs in areas where helminth infection is common. The WHO state this will improve nutritional status, haemoglobin, and cognition and thus will improve health, intellect, and school attendance. Consequently, it is claimed that school performance will improve, child mortality will decline, and economic productivity will increase. Given the important health and societal benefits attributed to this intervention, we sought to determine whether they are based on reliable evidence. To summarize the effects of giving deworming drugs to children to treat soil-transmitted intestinal worms (nematode geohelminths) on weight, haemoglobin, and cognition; and the evidence of impact on physical well being, school attendance, school performance, and mortality. In February 2012, we searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, EMBASE, LILACS, mRCT, and reference lists, and registers of ongoing and completed trials. We selected randomized controlled trials (RCTs) and quasi-RCTs comparing deworming drugs for geohelminth worms with placebo or no treatment in children aged 16 years or less, reporting on weight, haemoglobin, and formal test of intellectual development. In cluster-RCTs treating communities or schools, we also sought data on school attendance, school performance, and mortality. We included trials that included health education with deworming. At least two authors independently assessed the trials, evaluated risk of bias, and extracted data. Continuous data were analysed using the mean difference (MD) with 95% confidence intervals (CI). Where data were missing, we contacted trial authors. We used GRADE to assess evidence quality, and this is reflected in the wording we used: high quality ("deworming improves...."); moderate quality ("deworming probably improves..."); low quality ("deworming may improve...."); and very low quality

  7. Parallel PWMs Based Fully Digital Transmitter with Wide Carrier Frequency Range

    PubMed Central

    Zhou, Bo; Zhang, Kun; Zhou, Wenbiao; Zhang, Yanjun; Liu, Dake

    2013-01-01

    The carrier-frequency (CF) and intermediate-frequency (IF) pulse-width modulators (PWMs) based on delay lines are proposed, where baseband signals are conveyed by both positions and pulse widths or densities of the carrier clock. By combining IF-PWM and precorrected CF-PWM, a fully digital transmitter with unit-delay autocalibration is implemented in 180 nm CMOS for high reconfiguration. The proposed architecture achieves wide CF range of 2 M–1 GHz, high power efficiency of 70%, and low error vector magnitude (EVM) of 3%, with spectrum purity of 20 dB optimized in comparison to the existing designs. PMID:24223503

  8. Estimating Motor Carrier Management Information System Crash File Underreporting from Carrier Records.

    DOT National Transportation Integrated Search

    2017-08-01

    This FMCSA-sponsored research investigated the claim that motor carriers have a substantial number of crashes in their own records that are not contained in the Motor Carrier Management Information System (MCMIS) crash file. Based on the results of t...

  9. Quantifying oxygen in paper-based cell cultures with luminescent thin film sensors.

    PubMed

    Boyce, Matthew W; Kenney, Rachael M; Truong, Andrew S; Lockett, Matthew R

    2016-04-01

    Paper-based scaffolds are an attractive material for generating 3D tissue-like cultures because paper is readily available and does not require specialized equipment to pattern, cut, or use. By controlling the exchange of fresh culture medium with the paper-based scaffolds, we can engineer diffusion-dominated environments similar to those found in spheroids or solid tumors. Oxygen tension directly regulates cellular phenotype and invasiveness through hypoxia-inducible transcription factors and also has chemotactic properties. To date, gradients of oxygen generated in the paper-based cultures have relied on cellular response-based readouts. In this work, we prepared a luminescent thin film capable of quantifying oxygen tensions in apposed cell-containing paper-based scaffolds. The oxygen sensors, which are polystyrene films containing a Pd(II) tetrakis(pentafluorophenyl)porphyrin dye, are photostable, stable in culture conditions, and not cytotoxic. They have a linear response for oxygen tensions ranging from 0 to 160 mmHg O2, and a Stern-Volmer constant (K sv) of 0.239 ± 0.003 mmHg O2 (-1). We used these oxygen-sensing films to measure the spatial and temporal changes in oxygen tension for paper-based cultures containing a breast cancer line that was engineered to constitutively express a fluorescent protein. By acquiring images of the oxygen-sensing film and the fluorescently labeled cells, we were able to approximate the oxygen consumption rates of the cells in our cultures.

  10. Simultaneous transmission of wired and wireless signals based on double sideband carrier suppression

    NASA Astrophysics Data System (ADS)

    Bitew, Mekuanint Agegnehu; Shiu, Run-Kai; Peng, Peng-Chun; Wang, Cheng-Hao; Chen, Yan-Ming

    2017-11-01

    In this paper, we proposed and experimentally demonstrated simultaneous transmission of wired and wireless signals based on double sideband optical carrier suppression. By properly adjusting the bias point of the dual-output mach-zehnder modulator (MZM), a central carrier in one output port and a pair of first-order sidebands in another output port are generated. The pair of first-order sidebands are fed into a second MZM to generate second-order order sidebands. A wired signal is embedded on the central carrier while a wireless signal is embedded on the second-order sidebands. Unlike other schemes, we did not use optical filter to separate the carrier from the optical sidebands. The measured bit error rate (BER) and eye-diagrams after a 25 km single-mode-fiber (SMF) transmission proved that the proposed scheme is successful for both wired and wireless signals transmission. Moreover, the power penalty at the BER of 10-9 is 0.3 and 0.7 dB for wired and wireless signals, respectively.

  11. Unmanned Carrier-Based Aircraft System: Debate over Systems Role Led to Focus on Aerial Refueling

    DTIC Science & Technology

    2016-03-24

    Unmanned Carrier-Based Aircraft System: Debate over System’s Role Led to Focus on Aerial Refueling Prior to February 2016, the Navy had planned to...award of the air system development contract by about 3 years from 2014 to 2017. In that report, we also found that knowledge the Navy had obtained...strike 1Pub. L. No. 113-66, § 213(d) (2013). 2GAO, Unmanned Carrier-Based Aircraft System: Navy Needs

  12. The Prevalence of Self-Reported Health Problems and Haemoglobin Status of Sudanese Adolescents

    ERIC Educational Resources Information Center

    Moukhyer, M. E.; de Vries, N. K.; Bosma, H.; van Eijk, J. Th. M.

    2006-01-01

    In this paper we describe self-reported health problems and haemoglobin status among 1200 Sudanese adolescents (53.2% females, 46.8% males). Many adolescents report their general health as excellent and good (84%). A large number, however, report separate physical and psychological complaints. Report of psychological complaints is equal for both…

  13. Active oxygen doctors the evidence

    NASA Astrophysics Data System (ADS)

    Castelló, Ana; Francès, Francesc; Corella, Dolores; Verdú, Fernando

    2009-02-01

    Investigation at the scene of a crime begins with the search for clues. In the case of bloodstains, the most frequently used reagents are luminol and reduced phenolphthalein (or phenolphthalin that is also known as the Kastle-Meyer colour test). The limitations of these reagents have been studied and are well known. Household cleaning products have evolved with the times, and new products with active oxygen are currently widely used, as they are considered to be highly efficient at removing all kinds of stains on a wide range of surfaces. In this study, we investigated the possible effects of these new cleaning products on latent bloodstains that may be left at a scene of a crime. To do so, various fabrics were stained with blood and then washed using cleaning agents containing active oxygen. The results of reduced phenolphthalein, luminol and human haemoglobin tests on the washed fabrics were negative. The conclusion is that these new products alter blood to such an extent that it can no longer be detected by currently accepted methods employed in criminal investigations. This inability to locate bloodstains means that highly important evidence (e.g. a DNA profile) may be lost. Consequently, it is important that investigators are aware of this problem so as to compensate for it.

  14. Active oxygen doctors the evidence.

    PubMed

    Castelló, Ana; Francès, Francesc; Corella, Dolores; Verdú, Fernando

    2009-02-01

    Investigation at the scene of a crime begins with the search for clues. In the case of bloodstains, the most frequently used reagents are luminol and reduced phenolphthalein (or phenolphthalin that is also known as the Kastle-Meyer colour test). The limitations of these reagents have been studied and are well known. Household cleaning products have evolved with the times, and new products with active oxygen are currently widely used, as they are considered to be highly efficient at removing all kinds of stains on a wide range of surfaces. In this study, we investigated the possible effects of these new cleaning products on latent bloodstains that may be left at a scene of a crime. To do so, various fabrics were stained with blood and then washed using cleaning agents containing active oxygen. The results of reduced phenolphthalein, luminol and human haemoglobin tests on the washed fabrics were negative. The conclusion is that these new products alter blood to such an extent that it can no longer be detected by currently accepted methods employed in criminal investigations. This inability to locate bloodstains means that highly important evidence (e.g. a DNA profile) may be lost. Consequently, it is important that investigators are aware of this problem so as to compensate for it.

  15. Oxygen-induced recombination centers in as-grown Czochralski silicon crystals

    NASA Technical Reports Server (NTRS)

    Nauka, K.; Gatos, H. C.; Lagowski, J.

    1983-01-01

    Simultaneous quantitative microprofiles of the interstitial oxygen concentration and of the excess carrier lifetime are obtained in Czochralski-grown Si crystals employing double laser absorption scanning. It is found that oxygen concentration maxima and minima along the crystal growth direction coincide with lifetime minima and maxima, respectively. Another finding is that the magnitude of oxygen-induced lifetime changes increases dramatically in going from the center to the periphery of the crystal. The findings discussed imply that 'as-grown' oxygen precipitates figure in lifetime-limiting processes.

  16. Influence of carrier filling ratio on the performance of moving bed biofilm reactor in treating coking wastewater.

    PubMed

    Gu, Qiyuan; Sun, Tichang; Wu, Gen; Li, Mingyue; Qiu, Wei

    2014-08-01

    This study aims to evaluate the effect of carrier filling ratio on the performance of a moving bed biofilm reactor in degrading chemical oxygen demand, phenol, thiocyanate, and ammonia from coking wastewater at 20h of hydraulic retention time. The operational experiments under different carrier filling ratios ranging from 20% to 60% were investigated. The maximum removal efficiency of 89%, 99% and 99% for COD, phenol and thiocyanate, and minimum sensitivity to the increasing contaminants concentration in the influent were achieved at 50% carrier filling ratio. The Haldane competitive substrate inhibition kinetics model was used to describe the relationship between the oxygen uptake rate of ammonium oxidizers and the concentration of free ammonium. The highest biofilm microbial community functional diversity (Shannon's diversity index, H') and evenness (Shannon's evenness index, E') were obtained at 50% carrier filling ratio in all runs using a Biolog ECO microplate. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Experimental manipulations of tissue oxygen supply do not affect warming tolerance of European perch.

    PubMed

    Brijs, Jeroen; Jutfelt, Fredrik; Clark, Timothy D; Gräns, Albin; Ekström, Andreas; Sandblom, Erik

    2015-08-01

    A progressive inability of the cardiorespiratory system to maintain systemic oxygen supply at elevated temperatures has been suggested to reduce aerobic scope and the upper thermal limit of aquatic ectotherms. However, few studies have directly investigated the dependence of thermal limits on oxygen transport capacity. By manipulating oxygen availability (via environmental hyperoxia) and blood oxygen carrying capacity (via experimentally induced anaemia) in European perch (Perca fluviatilis Linneaus), we investigated the effects of oxygen transport capacity on aerobic scope and the critical thermal maximum (CT(max)). Hyperoxia resulted in a twofold increase in aerobic scope at the control temperature of 23°C, but this did not translate to an elevated CT(max) in comparison with control fish (34.6±0.1 versus 34.0±0.5°C, respectively). Anaemia (∼43% reduction in haemoglobin concentration) did not cause a reduction in aerobic scope or CT(max) (33.8±0.3°C) compared with control fish. Additionally, oxygen consumption rates of anaemic perch during thermal ramping increased in a similar exponential manner to that in control fish, highlighting that perch have an impressive capacity to compensate for a substantial reduction in blood oxygen carrying capacity. Taken together, these results indicate that oxygen limitation is not a universal mechanism determining the CT(max) of fishes. © 2015. Published by The Company of Biologists Ltd.

  18. Investigating and Optimizing Carrier Transport, Carrier Distribution, and Efficiency Droop in GaN-based Light-emitting Diodes

    NASA Astrophysics Data System (ADS)

    Zhu, Di

    2011-12-01

    The recent tremendous boost in the number and diversity of applications for light-emitting diodes (LEDs) indicates the emergence of the next-generation lighting and illumination technology. The rapidly improving LED technology is becoming increasingly viable especially for high-power applications. However, the greatest roadblock before finally breaching the main defensive position of conventional fluorescent and incandescent lamps still remains: GaN-based LEDs encounter a significant decrease in efficiency as the drive current increases, and this phenomenon is known as the efficiency droop. This dissertation focuses on uncovering the physical cause of efficiency droop in GaN-based LEDs and looks for solutions to it. GaN-based multiple-quantum-well (MQW) LEDs usually have abnormally high diode-ideality factors. Investigating the origin of the high diode-ideality factors could help to better understand the carrier transport in the LED MQW active region. We investigate the ideality factors of GaInN LEDs with different numbers of doped quantum barriers (QBs). Consistent with the theory, a decrease of the ideality factor as well as a reduction in forward voltage is found with increasing number of doped QBs. Experimental and simulation results indicate that the band profiles of QBs in the active region have a significant impact on the carrier transport mechanism, and the unipolar heterojunctions inside the active region play an important role in determining the diode-ideality factor. This dissertation will discuss several mechanisms leading to electron leakage which could be responsible for the efficiency droop. We show that the inefficient electron capture, the electron-attracting properties of polarized EBL, the inherent asymmetry in electron and hole transport and the inefficient EBL p-doping at high Al contents severely limit the ability to confine electrons to the MQWs. We demonstrate GaInN LEDs employing tailored Si doping in the QBs with strongly enhanced high

  19. A Novel Bio-carrier Fabricated Using 3D Printing Technique for Wastewater Treatment

    PubMed Central

    Dong, Yang; Fan, Shu-Qian; Shen, Yu; Yang, Ji-Xiang; Yan, Peng; Chen, You-Peng; Li, Jing; Guo, Jin-Song; Duan, Xuan-Ming; Fang, Fang; Liu, Shao-Yang

    2015-01-01

    The structure of bio-carriers is one of the key operational characteristics of a biofilm reactor. The goal of this study is to develop a series of novel fullerene-type bio-carriers using the three-dimensional printing (3DP) technique. 3DP can fabricate bio-carriers with more specialized structures compared with traditional fabrication processes. In this research, three types of fullerene-type bio-carriers were fabricated using the 3DP technique and then compared with bio-carrier K3 (from AnoxKaldnes) in the areas of physicochemical properties and biofilm growth. Images acquired by 3D profiling and SEM indicated that the surface roughness of the 3DP bio-carrier was greater than that of K3. Furthermore, contact angle data indicated that the 3DP bio-carriers were more hydrophilic than K3. The biofilm on the 3DP bio-carriers exhibited higher microbial activity and stronger adhesion ability. These findings were attributed to excellent mass transfer of the substrate (and oxygen) between the vapour-liquid-solid tri-phase system and to the surface characteristics. It is concluded that the novel 3DP fullerene-type bio-carriers are ideal carriers for biofilm adherence and growth. PMID:26202477

  20. A Novel Bio-carrier Fabricated Using 3D Printing Technique for Wastewater Treatment.

    PubMed

    Dong, Yang; Fan, Shu-Qian; Shen, Yu; Yang, Ji-Xiang; Yan, Peng; Chen, You-Peng; Li, Jing; Guo, Jin-Song; Duan, Xuan-Ming; Fang, Fang; Liu, Shao-Yang

    2015-07-23

    The structure of bio-carriers is one of the key operational characteristics of a biofilm reactor. The goal of this study is to develop a series of novel fullerene-type bio-carriers using the three-dimensional printing (3DP) technique. 3DP can fabricate bio-carriers with more specialized structures compared with traditional fabrication processes. In this research, three types of fullerene-type bio-carriers were fabricated using the 3DP technique and then compared with bio-carrier K3 (from AnoxKaldnes) in the areas of physicochemical properties and biofilm growth. Images acquired by 3D profiling and SEM indicated that the surface roughness of the 3DP bio-carrier was greater than that of K3. Furthermore, contact angle data indicated that the 3DP bio-carriers were more hydrophilic than K3. The biofilm on the 3DP bio-carriers exhibited higher microbial activity and stronger adhesion ability. These findings were attributed to excellent mass transfer of the substrate (and oxygen) between the vapour-liquid-solid tri-phase system and to the surface characteristics. It is concluded that the novel 3DP fullerene-type bio-carriers are ideal carriers for biofilm adherence and growth.

  1. Acquisition of exogenous haem is essential for tick reproduction

    PubMed Central

    Perner, Jan; Sobotka, Roman; Sima, Radek; Konvickova, Jitka; Sojka, Daniel; de Oliveira, Pedro Lagerblad; Hajdusek, Ondrej; Kopacek, Petr

    2016-01-01

    Haem and iron homeostasis in most eukaryotic cells is based on a balanced flux between haem biosynthesis and haem oxygenase-mediated degradation. Unlike most eukaryotes, ticks possess an incomplete haem biosynthetic pathway and, together with other (non-haematophagous) mites, lack a gene encoding haem oxygenase. We demonstrated, by membrane feeding, that ticks do not acquire bioavailable iron from haemoglobin-derived haem. However, ticks require dietary haemoglobin as an exogenous source of haem since, feeding with haemoglobin-depleted serum led to aborted embryogenesis. Supplementation of serum with haemoglobin fully restored egg fertility. Surprisingly, haemoglobin could be completely substituted by serum proteins for the provision of amino-acids in vitellogenesis. Acquired haem is distributed by haemolymph carrier protein(s) and sequestered by vitellins in the developing oocytes. This work extends, substantially, current knowledge of haem auxotrophy in ticks and underscores the importance of haem and iron metabolism as rational targets for anti-tick interventions. DOI: http://dx.doi.org/10.7554/eLife.12318.001 PMID:26949258

  2. Carrier doping into a superconducting BaPb0.7Bi0.3O3‑δ epitaxial film using an electric double-layer transistor structure

    NASA Astrophysics Data System (ADS)

    Komori, S.; Kakeya, I.

    2018-06-01

    Doping evolution of the unconventional superconducting properties in BaBiO3-based compounds has yet to be clarified in detail due to the significant change of the oxygen concentration accompanied by the chemical substitution. We suggest that the carrier concentration of an unconventional superconductor, BaPb0.7Bi0.3O3‑δ , is controllable without inducing chemical or structural changes using an electric double-layer transistor structure. The critical temperature is found to decrease systematically with increasing carrier concentration.

  3. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2013-02-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  4. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2012-11-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  5. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2013-05-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  6. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2012-08-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  7. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2013-06-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  8. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2013-04-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  9. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2012-09-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  10. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2013-03-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  11. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2013-01-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  12. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2012-10-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  13. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2012-12-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  14. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2014-05-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  15. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2014-03-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  16. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2014-04-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  17. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2014-06-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  18. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2014-02-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  19. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2013-07-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  20. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2013-09-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  1. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2013-08-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  2. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2010-07-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  3. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2012-02-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  4. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2012-05-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  5. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2010-09-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  6. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2006-12-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  7. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2011-11-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  8. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2009-01-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  9. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2010-05-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  10. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2011-08-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  11. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2012-07-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  12. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2009-03-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  13. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2009-05-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  14. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2011-01-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  15. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2009-09-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  16. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2011-02-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  17. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2011-07-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  18. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2010-06-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  19. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2004-12-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  20. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2009-12-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  1. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2012-03-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  2. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2003-12-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  3. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2009-04-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  4. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2010-04-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  5. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2010-08-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  6. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2011-05-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  7. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2010-10-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  8. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2012-04-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  9. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2011-10-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  10. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2011-04-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  11. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2009-11-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  12. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2010-01-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  13. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2009-07-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  14. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2002-12-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  15. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2012-06-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  16. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2009-06-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  17. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2009-08-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  18. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2010-12-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  19. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2009-02-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  20. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2008-12-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  1. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2010-02-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  2. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2007-12-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  3. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2011-09-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  4. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2005-12-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  5. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2011-12-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  6. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2010-03-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  7. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2009-10-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  8. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2012-01-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  9. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2011-06-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  10. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2010-11-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  11. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2011-03-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  12. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2014-01-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  13. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2013-11-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  14. Air Carrier Traffic Statistics.

    DOT National Transportation Integrated Search

    2013-12-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  15. Amorphous Silica Based Nanomedicine with Safe Carrier Excretion and Enhanced Drug Efficacy

    NASA Astrophysics Data System (ADS)

    Zhang, Silu

    With recent development of nanoscience and nanotechnology, a great amount of efforts have been devoted to nanomedicine development. Among various nanomaterials, silica nanoparticle (NP) is generally accepted as non-toxic, and can provide a versatile platform for drug loading. In addition, the surface of the silica NP is hydrophilic, being favorable for cellular uptake. Therefore, it is considered as one of the most promising candidates to serve as carriers for drugs. The present thesis mainly focuses on the design of silica based nanocarrier-drug systems, aiming at achieving safe nanocarrier excretion from the biological system and enhanced drug efficacy, which two are considered as most important issues in nanomedicine development. To address the safe carrier excretion issue, we have developed a special type of selfdecomposable SiO2-drug composite NPs. By creating a radial concentration gradient of drug in the NP, the drug release occurred simultaneously with the silica carrier decomposition. Such unique characteristic was different from the conventional dense SiO2-drug NP, in which drug was uniformly distributed and can hardly escape the carrier. We found that the controllable release of the drug was primarily determined by diffusion, which was caused by the radial drug concentration gradient in the NP. Escape of the drug molecules then triggered the silica carrier decomposition, which started from the center of the NP and eventually led to its complete fragmentation. The small size of the final carrier fragments enabled their easy excretion via renal systems. Apart from the feature of safe carrier excretion, we also found the controlled release of drugs contribute significantly to the drug efficacy enhancement. By loading an anticancer drug doxorubicin (Dox) to the decomposable SiO 2-methylene blue (MB) NPs, we achieved a self-decomposable SiO 2(MB)-Dox nanomedicine. The gradual escape of drug molecules from NPs and their enabled cytosolic release by optical

  16. 14 CFR Section 04 - Air Carrier Groupings

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Air Carrier Groupings Section 04 Section 04... REGULATIONS UNIFORM SYSTEM OF ACCOUNTS AND REPORTS FOR LARGE CERTIFICATED AIR CARRIERS Section 04 Air Carrier Groupings (a) All large certificated air carriers are placed into three basic air carrier groupings based...

  17. 14 CFR Section 04 - Air Carrier Groupings

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Air Carrier Groupings Section 04 Section 04... REGULATIONS UNIFORM SYSTEM OF ACCOUNTS AND REPORTS FOR LARGE CERTIFICATED AIR CARRIERS Section 04 Air Carrier Groupings (a) All large certificated air carriers are placed into three basic air carrier groupings based...

  18. 14 CFR Section 04 - Air Carrier Groupings

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Air Carrier Groupings Section 04 Section 04... REGULATIONS UNIFORM SYSTEM OF ACCOUNTS AND REPORTS FOR LARGE CERTIFICATED AIR CARRIERS Section 04 Air Carrier Groupings (a) All large certificated air carriers are placed into three basic air carrier groupings based...

  19. 14 CFR Section 04 - Air Carrier Groupings

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Air Carrier Groupings Section 04 Section 04... REGULATIONS UNIFORM SYSTEM OF ACCOUNTS AND REPORTS FOR LARGE CERTIFICATED AIR CARRIERS Section 04 Air Carrier Groupings (a) All large certificated air carriers are placed into three basic air carrier groupings based...

  20. Pilot study of oxygen transport rate of banked red blood cells.

    PubMed

    Buchwald, H; Menchaca, H J; Michalek, V N; Rudser, K D; Rohde, T D; O'Dea, T; Connett, J E; Gorlin, J

    2009-01-01

    Dynamic oximetry provides a new way to assess the effect of blood storage on the oxygen transport rate (OTR). In dynamic oximetry, the rate at which oxyhemoglobin becomes deoxyhemoglobin is measured optically, thereby, indirectly measuring the rate at which oxygen leaves the red blood cell (RBC) making it available for transfer to tissues. Extending the physiologic diffusion time in an in vitro apparatus, consisting of a diffusion system and gas exchanger capable of controlling the surface area and the time of exposure for oxygenation and deoxygenation, makes OTR measurement feasible. Eight normal blood donor units, collected in adenine, dextrose, sorbitol, sodium chloride and mannitol , were stored for 8 weeks under standard conditions and serially sampled for OTR. We report that the OTR at the time of blood bank donation appears to be singular for each donor, that the interdonor differences are maintained over time, and that the individual OTR increased 1.72-fold (95% CI 1.51, 1.95) over 8 weeks, adjusting for sex, age and plasma cholesterol level. Oxygen transport rate increases during storage; blood units with similar haemoglobin content may have significant differences in OTR. Studies examining blood parameters at the time of donation and blood storage on patient outcomes should consider measuring OTR, as it may contribute to differences in observed efficacy of tissue oxygenation.

  1. 20. VIEW OF WORTHINGTON BASE LOAD OXYGEN COMPRESSOR IN THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. VIEW OF WORTHINGTON BASE LOAD OXYGEN COMPRESSOR IN THE HIGH PURITY OXYGEN BUILDING LOOKING NORTH. - U.S. Steel Duquesne Works, Fuel & Utilities Plant, Along Monongahela River, Duquesne, Allegheny County, PA

  2. Use of Isolated Mitochondria and Pulmonary Artery Endothelial Cell Systems in Studies of Oxygen Utilization and the Effects of Hemoglobin-Based Oxygen Carriers

    DTIC Science & Technology

    2008-07-16

    mitochondria through the monocarboxylate transporter and feed in to the Kreb’s cycle to yield 34 ATPs via oxidative phosphorylation as follows (assuming a... Krebs (tricarboxylic acid) cycle enzyme, and is found mainly in the mitochondrial matrix (8). Therefore, its measured enzymatic activity serves as an...APPROVAL SHEET Title of Thesis: "Use of Isolated Mitochondria and Pulmonary Artery Endothelial Cell Systems in Studies of Oxygen Utilization and the

  3. Optimization measurement of muscle oxygen saturation under isometric studies using FNIRS

    NASA Astrophysics Data System (ADS)

    Halim, A. A. A.; Laili, M. H.; Salikin, M. S.; Rusop, M.

    2018-05-01

    Development of functional near infrared spectroscopy (fNIRS) technologies has advanced quantification signal using multiple wavelength and detector to investigate hemodynamic response in human muscle. These non-invasive technologies have been widely used to solve the propagation of light inside the tissues including the absorption, scattering coefficient and to quantify the oxygenation level of haemoglobin and myoglobin in human muscle. The goal of this paper is to optimize the measurement of muscle oxygen saturation during isometric exercise using functional near infrared spectroscopy (fNIRS). The experiment was carried out on 15 sedentary healthy male volunteers. All volunteers are required to perform an isometric exercise at three assessment of muscular fatigue's level on flexor digitalis (FDS) muscle in the human forearm using fNIRS. The slopes of the signals have been highlighted to evaluate the muscle oxygen saturation of regional muscle fatigue. As a result, oxygen saturation slope from 10% exercise showed steeper than the first assessment at 30%-50% of fatigues level. The hemodynamic signal response showed significant value (p=0.04) at all three assessment of muscular fatigue's level which produce a p-value (p<0.05) measured by fNIRS. Thus, this highlighted parameter could be used to estimate fatigue's level of human and could open other possibilities to study muscle performance diagnosis.

  4. On the mobility of carriers at semi-coherent oxide heterointerfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dholabhai, Pratik P.; Martinez, Enrique Saez; Brown, Nicholas Taylor

    In the quest to develop new materials with enhanced ionic conductivity for battery and fuel cell applications, nano-structured oxides have attracted attention. Experimental reports indicate that oxide heterointerfaces can lead to enhanced ionic conductivity, but these same reports cannot elucidate the origin of this enhancement, often vaguely referring to pipe diffusion at misfit dislocations as a potential explanation. However, this highlights the need to understand the role of misfit dislocation structure at semi-coherent oxide heterointerfaces in modifying carrier mobilities. Here, we use atomistic and kinetic Monte Carlo (KMC) simulations to develop a model of oxygen vacancy migration at SrTiO 3/MgOmore » interfaces, chosen because the misfit dislocation structure can be modified by changing the termination chemistry. We use atomistic simulations to determine the energetics of oxygen vacancies at both SrO and TiO 2 terminated interfaces, which are then used as the basis of the KMC simulations. While this model is approximate (as revealed by select nudged elastic band calculations), it highlights the role of the misfit dislocation structure in modifying the oxygen vacancy dynamics. We find that oxygen vacancy mobility is significantly reduced at either interface, with slight differences at each interface due to the differing misfit dislocation structure. Here, we conclude that if such semi-coherent oxide heterointerfaces induce enhanced ionic conductivity, it is not a consequence of higher carrier mobility.« less

  5. On the mobility of carriers at semi-coherent oxide heterointerfaces

    DOE PAGES

    Dholabhai, Pratik P.; Martinez, Enrique Saez; Brown, Nicholas Taylor; ...

    2017-08-17

    In the quest to develop new materials with enhanced ionic conductivity for battery and fuel cell applications, nano-structured oxides have attracted attention. Experimental reports indicate that oxide heterointerfaces can lead to enhanced ionic conductivity, but these same reports cannot elucidate the origin of this enhancement, often vaguely referring to pipe diffusion at misfit dislocations as a potential explanation. However, this highlights the need to understand the role of misfit dislocation structure at semi-coherent oxide heterointerfaces in modifying carrier mobilities. Here, we use atomistic and kinetic Monte Carlo (KMC) simulations to develop a model of oxygen vacancy migration at SrTiO 3/MgOmore » interfaces, chosen because the misfit dislocation structure can be modified by changing the termination chemistry. We use atomistic simulations to determine the energetics of oxygen vacancies at both SrO and TiO 2 terminated interfaces, which are then used as the basis of the KMC simulations. While this model is approximate (as revealed by select nudged elastic band calculations), it highlights the role of the misfit dislocation structure in modifying the oxygen vacancy dynamics. We find that oxygen vacancy mobility is significantly reduced at either interface, with slight differences at each interface due to the differing misfit dislocation structure. Here, we conclude that if such semi-coherent oxide heterointerfaces induce enhanced ionic conductivity, it is not a consequence of higher carrier mobility.« less

  6. Recent Advances in Lipid-Based Vesicles and Particulate Carriers for Topical and Transdermal Application.

    PubMed

    Jain, Shashank; Patel, Niketkumar; Shah, Mansi K; Khatri, Pinak; Vora, Namrata

    2017-02-01

    In the recent decade, skin delivery (topical and transdermal) has gained an unprecedented popularity, especially due to increased incidences of chronic skin diseases, demand for targeted and patient compliant delivery, and interest in life cycle management strategies among pharmaceutical companies. Literature review of recent publications indicates that among various skin delivery systems, lipid-based delivery systems (vesicular carriers and lipid particulate systems) have been the most successful. Vesicular carriers consist of liposomes, ultradeformable liposomes, and ethosomes, while lipid particulate systems consist of lipospheres, solid lipid nanoparticles, and nanostructured lipid carriers. These systems can increase the skin drug transport by improving drug solubilization in the formulation, drug partitioning into the skin, and fluidizing skin lipids. Considering that lipid-based delivery systems are regarded as safe and efficient, they are proving to be an attractive delivery strategy for the pharmaceutical as well as cosmeceutical drug substances. However, development of these delivery systems requires comprehensive understanding of physicochemical characteristics of drug and delivery carriers, formulation and process variables, mechanism of skin delivery, recent technological advancements, specific limitations, and regulatory considerations. Therefore, this review article encompasses recent research advances addressing the aforementioned issues. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  7. Sulfur evolution in chemical looping combustion of coal with MnFe2O4 oxygen carrier.

    PubMed

    Wang, Baowen; Gao, Chuchang; Wang, Weishu; Zhao, Haibo; Zheng, Chuguang

    2014-05-01

    Chemical looping combustion (CLC) of coal has gained increasing attention as a novel combustion technology for its advantages in CO2 capture. Sulfur evolution from coal causes great harm from either the CLC operational or environmental perspective. In this research, a combined MnFe2O4 oxygen carrier (OC) was synthesized and its reaction with a typical Chinese high sulfur coal, Liuzhi (LZ) bituminous coal, was performed in a thermogravimetric analyzer (TGA)-Fourier transform infrared (FT-IR) spectrometer. Evolution of sulfur species during reaction of LZ coal with MnFe2O4 OC was systematically investigated through experimental means combined with thermodynamic simulation. TGA-FTIR analysis of the LZ reaction with MnFe2O4 indicated MnFe2O4 exhibited the desired superior reactivity compared to the single reference oxides Mn3O4 or Fe2O3, and SO2 produced was mainly related to oxidization of H2S by MnFe2O4. Experimental analysis of the LZ coal reaction with MnFe2O4, including X-ray diffraction and X-ray photoelectron spectroscopy analysis, verified that the main reduced counterparts of MnFe2O4 were Fe3O4 and MnO, in good agreement with the related thermodynamic simulation. The obtained MnO was beneficial to stabilize the reduced MnFe2O4 and avoid serious sintering, although the oxygen in MnO was not fully utilized. Meanwhile, most sulfur present in LZ coal was converted to solid MnS during LZ reaction with MnFe2O4, which was further oxidized to MnSO4. Finally, the formation of both MnS and such manganese silicates as Mn2SiO4 and MnSiO3 should be addressed to ensure the full regeneration of the reduced MnFe2O4. Copyright © 2014 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  8. Sickling of red blood cells through rapid oxygen exchange in microfluidic drops.

    PubMed

    Abbyad, Paul; Tharaux, Pierre-Louis; Martin, Jean-Louis; Baroud, Charles N; Alexandrou, Antigoni

    2010-10-07

    We have developed a microfluidic approach to study the sickling of red blood cells associated with sickle cell anemia by rapidly varying the oxygen partial pressure within flowing microdroplets. By using the perfluorinated carrier oil as a sink or source of oxygen, the oxygen level within the water droplets quickly equilibrates through exchange with the surrounding oil. This provides control over the oxygen partial pressure within an aqueous drop ranging from 1 kPa to ambient partial pressure, i.e. 21 kPa. The dynamics of the oxygen exchange is characterized through fluorescence lifetime measurements of a ruthenium compound dissolved in the aqueous phase. The gas exchange is shown to occur primarily during and directly after droplet formation, in 0.1 to 0.5 s depending on the droplet diameter and speed. The controlled deoxygenation is used to trigger the polymerization of hemoglobin within sickle red blood cells, encapsulated in drops. This process is observed using polarization microscopy, which yields a robust criterion to detect polymerization based on transmitted light intensity through crossed polarizers.

  9. A nursing educational intervention helped by One Touch UltraSmart improves monitoring and glycated haemoglobin levels in type I diabetic children.

    PubMed

    Aguilar, María J; García, Pedro A; González, Emilio; Pérez, María C; Padilla, Carlos A

    2012-04-01

    To improve the monitoring and control of glycated haemoglobin in insulin-dependent children. This article describes an educational intervention for this purpose where One Touch UltraSmart Software was used to manage diabetes. The results showed that this intervention helped to reduce the levels of blood glucose and glycated haemoglobin to less than 7%. Various research studies have been performed on the effective control of glycated haemoglobin values in diabetic children by means of technological devices. However, none of this research has evaluated the impact of an educational intervention in conjunction with the use of monitoring instruments such as One Touch UltraSmart. We present an 18-month longitudinal, analytical and observational study of 37 type 1 diabetic patients, 9-16 years of age. For each patient, initial and final values of glycated haemoglobin and the number of blood glucose controls were recorded. For the purposes of our study seven educational workshops, attended by diabetic children and their parents, were conducted. In addition, participants were asked to complete a brief questionnaire so that information could be gathered regarding the eating and exercise habits of the patients. This educational intervention using One Touch UltraSmart led to a statistically significant average reduction of glycated haemoglobin. Our research showed that the use of One Touch UltraSmart in the context of an educational intervention raised the awareness of the diabetic children and thus helped them to effectively control their disease and to fully understand the necessity of having good dietary and exercise habits. It can be concluded that the educational intervention led to a significant improvement in the dietary habits of these patients and also helped them to exercise regularly, all of which has a positive impact on their health. © 2012 Blackwell Publishing Ltd.

  10. Lipid-based colloidal carriers for peptide and protein delivery – liposomes versus lipid nanoparticles

    PubMed Central

    Martins, Susana; Sarmento, Bruno; Ferreira, Domingos C; Souto, Eliana B

    2007-01-01

    This paper highlights the importance of lipid-based colloidal carriers and their pharmaceutical implications in the delivery of peptides and proteins for oral and parenteral administration. There are several examples of biomacromolecules used nowadays in the therapeutics, which are promising candidates to be delivered by means of liposomes and lipid nanoparticles, such as solid lipid nanoparticles (SLN) and nanostructured lipid carriers (NLC). Several production procedures can be applied to achieve a high association efficiency between the bioactives and the carrier, depending on the physicochemical properties of both, as well as on the production procedure applied. Generally, this can lead to improved bioavailability, or in case of oral administration a more consistent temporal profile of absorption from the gastrointestinal tract. Advantages and drawbacks of such colloidal carriers are also pointed out. This article describes strategies used for formulation of peptides and proteins, methods used for assessment of association efficiency and practical considerations regarding the toxicological concerns. PMID:18203427

  11. Responsible implementation of expanded carrier screening

    PubMed Central

    Henneman, Lidewij; Borry, Pascal; Chokoshvili, Davit; Cornel, Martina C; van El, Carla G; Forzano, Francesca; Hall, Alison; Howard, Heidi C; Janssens, Sandra; Kayserili, Hülya; Lakeman, Phillis; Lucassen, Anneke; Metcalfe, Sylvia A; Vidmar, Lovro; de Wert, Guido; Dondorp, Wybo J; Peterlin, Borut

    2016-01-01

    This document of the European Society of Human Genetics contains recommendations regarding responsible implementation of expanded carrier screening. Carrier screening is defined here as the detection of carrier status of recessive diseases in couples or persons who do not have an a priori increased risk of being a carrier based on their or their partners' personal or family history. Expanded carrier screening offers carrier screening for multiple autosomal and X-linked recessive disorders, facilitated by new genetic testing technologies, and allows testing of individuals regardless of ancestry or geographic origin. Carrier screening aims to identify couples who have an increased risk of having an affected child in order to facilitate informed reproductive decision making. In previous decades, carrier screening was typically performed for one or few relatively common recessive disorders associated with significant morbidity, reduced life-expectancy and often because of a considerable higher carrier frequency in a specific population for certain diseases. New genetic testing technologies enable the expansion of screening to multiple conditions, genes or sequence variants. Expanded carrier screening panels that have been introduced to date have been advertised and offered to health care professionals and the public on a commercial basis. This document discusses the challenges that expanded carrier screening might pose in the context of the lessons learnt from decades of population-based carrier screening and in the context of existing screening criteria. It aims to contribute to the public and professional discussion and to arrive at better clinical and laboratory practice guidelines. PMID:26980105

  12. The use of carrier RNA to enhance DNA extraction from microfluidic-based silica monoliths.

    PubMed

    Shaw, Kirsty J; Thain, Lauren; Docker, Peter T; Dyer, Charlotte E; Greenman, John; Greenway, Gillian M; Haswell, Stephen J

    2009-10-12

    DNA extraction was carried out on silica-based monoliths within a microfluidic device. Solid-phase DNA extraction methodology was applied in which the DNA binds to silica in the presence of a chaotropic salt, such as guanidine hydrochloride, and is eluted in a low ionic strength solution, such as water. The addition of poly-A carrier RNA to the chaotropic salt solution resulted in a marked increase in the effective amount of DNA that could be recovered (25ng) compared to the absence of RNA (5ng) using the silica-based monolith. These findings confirm that techniques utilising nucleic acid carrier molecules can enhance DNA extraction methodologies in microfluidic applications.

  13. Drug Carrier for Photodynamic Cancer Therapy

    PubMed Central

    Debele, Tilahun Ayane; Peng, Sydney; Tsai, Hsieh-Chih

    2015-01-01

    Photodynamic therapy (PDT) is a non-invasive combinatorial therapeutic modality using light, photosensitizer (PS), and oxygen used for the treatment of cancer and other diseases. When PSs in cells are exposed to specific wavelengths of light, they are transformed from the singlet ground state (S0) to an excited singlet state (S1–Sn), followed by intersystem crossing to an excited triplet state (T1). The energy transferred from T1 to biological substrates and molecular oxygen, via type I and II reactions, generates reactive oxygen species, (1O2, H2O2, O2*, HO*), which causes cellular damage that leads to tumor cell death through necrosis or apoptosis. The solubility, selectivity, and targeting of photosensitizers are important factors that must be considered in PDT. Nano-formulating PSs with organic and inorganic nanoparticles poses as potential strategy to satisfy the requirements of an ideal PDT system. In this review, we summarize several organic and inorganic PS carriers that have been studied to enhance the efficacy of photodynamic therapy against cancer. PMID:26389879

  14. Carrier transport and emission efficiency in InGaN quantum-dot based light-emitting diodes

    NASA Astrophysics Data System (ADS)

    Barettin, Daniele; Auf der Maur, Matthias; di Carlo, Aldo; Pecchia, Alessandro; Tsatsulnikov, Andrei F.; Lundin, Wsevolod V.; Sakharov, Alexei V.; Nikolaev, Andrei E.; Korytov, Maxim; Cherkashin, Nikolay; Hÿtch, Martin J.; Karpov, Sergey Yu

    2017-07-01

    We present a study of blue III-nitride light-emitting diodes (LEDs) with multiple quantum well (MQW) and quantum dot (QD) active regions (ARs), comparing experimental and theoretical results. The LED samples were grown by metalorganic vapor phase epitaxy, utilizing growth interruption in the hydrogen/nitrogen atmosphere and variable reactor pressure to control the AR microstructure. Realistic configuration of the QD AR implied in simulations was directly extracted from HRTEM characterization of the grown QD-based structures. Multi-scale 2D simulations of the carrier transport inside the multiple QD AR have revealed a non-trivial pathway for carrier injection into the dots. Electrons and holes are found to penetrate deep into the multi-layer AR through the gaps between individual QDs and get into the dots via their side edges rather than via top and bottom interfaces. This enables a more homogeneous carrier distribution among the dots situated in different layers than among the laterally uniform quantum well (QWs) in the MQW AR. As a result, a lower turn-on voltage is predicted for QD-based LEDs, as compared to MQW ones. Simulations did not show any remarkable difference in the efficiencies of the MQW and QD-based LEDs, if the same recombination coefficients are utilized, i.e. a similar crystal quality of both types of LED structures is assumed. Measurements of the current-voltage characteristics of LEDs with both kinds of the AR have shown their close similarity, in contrast to theoretical predictions. This implies the conventional assumption of laterally uniform QWs not to be likely an adequate approximation for the carrier transport in MQW LED structures. Optical characterization of MQW and QD-based LEDs has demonstrated that the later ones exhibit a higher efficiency, which could be attributed to better crystal quality of the grown QD-based structures. The difference in the crystal quality explains the recently observed correlation between the growth pressure of

  15. Carrier transport and emission efficiency in InGaN quantum-dot based light-emitting diodes.

    PubMed

    Barettin, Daniele; Auf der Maur, Matthias; di Carlo, Aldo; Pecchia, Alessandro; Tsatsulnikov, Andrei F; Lundin, Wsevolod V; Sakharov, Alexei V; Nikolaev, Andrei E; Korytov, Maxim; Cherkashin, Nikolay; Hÿtch, Martin J; Karpov, Sergey Yu

    2017-07-07

    We present a study of blue III-nitride light-emitting diodes (LEDs) with multiple quantum well (MQW) and quantum dot (QD) active regions (ARs), comparing experimental and theoretical results. The LED samples were grown by metalorganic vapor phase epitaxy, utilizing growth interruption in the hydrogen/nitrogen atmosphere and variable reactor pressure to control the AR microstructure. Realistic configuration of the QD AR implied in simulations was directly extracted from HRTEM characterization of the grown QD-based structures. Multi-scale 2D simulations of the carrier transport inside the multiple QD AR have revealed a non-trivial pathway for carrier injection into the dots. Electrons and holes are found to penetrate deep into the multi-layer AR through the gaps between individual QDs and get into the dots via their side edges rather than via top and bottom interfaces. This enables a more homogeneous carrier distribution among the dots situated in different layers than among the laterally uniform quantum well (QWs) in the MQW AR. As a result, a lower turn-on voltage is predicted for QD-based LEDs, as compared to MQW ones. Simulations did not show any remarkable difference in the efficiencies of the MQW and QD-based LEDs, if the same recombination coefficients are utilized, i.e. a similar crystal quality of both types of LED structures is assumed. Measurements of the current-voltage characteristics of LEDs with both kinds of the AR have shown their close similarity, in contrast to theoretical predictions. This implies the conventional assumption of laterally uniform QWs not to be likely an adequate approximation for the carrier transport in MQW LED structures. Optical characterization of MQW and QD-based LEDs has demonstrated that the later ones exhibit a higher efficiency, which could be attributed to better crystal quality of the grown QD-based structures. The difference in the crystal quality explains the recently observed correlation between the growth pressure of

  16. Physiological variations in levels of 2,3-diphosphoglycerate in horse erythrocytes.

    PubMed

    Lewis, I M; McLan, J G

    1975-03-01

    The levels of 2,3-diphosphoglycerate (2,3-DPG), which affects the transport of oxygen by haemoglobin, were examined in horse blood. Resting levels of erythrocyte 2,3-DPG were established in thoroughbred horses, and levels of 2,3-DPG together with haemoglobin levels, were examined in a variety of conditions. A negative correlation was observed between erythrocyte 2,3-DPG and haemoglobin levels. Mares had higher erythrocyte 2,3-DPG levels was observed during training, and this variation may have a significant effect on haemoglobin oxygen transport. Erythrocyte 2,3-DPG levels were not affected by age or exercise.

  17. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    NASA Astrophysics Data System (ADS)

    Kyriacou, P. A.; Shafqat, K.; Pal, S. K.

    2007-10-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO2) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  18. Carrier Density at LaAlO3/SrTiO3 Interfaces: Evidence of Electronic Reconstruction.

    NASA Astrophysics Data System (ADS)

    Xi, Xiaoxing

    The origin of the 2D electron gas at the LaAlO3/SrTiO3 interface has been a controversial subject ever since its discovery. A serious inconsistency with the most accepted mechanism, an electronic reconstruction in response to a polar discontinuity at the interface, is that the carrier densities reported experimentally are invariably lower than the expected value except under conditions where reduction of SrTiO3 substrate is suspected. We have grown LaAlO3 films of different stoichiometry on TiO2-terminated SrTiO3 substrates using atomic layer-by-layer laser molecular beam epitaxy (ALL-Laser MBE), in which La2O3 and Al2O3 targets were sequentially ablated in 37 mTorr oxygen. The high oxygen pressure during growth prevents the possible oxygen reduction in SrTiO3, ensures that the LaAlO3 films are sufficiently oxygenated, and suppresses the La-Sr intermixing due to the bombardment effect. X-ray linear dichroism (XLD) and x-ray magnetic circular dichroism (XMCD) measurements show characteristics of oxygenated samples. In the electronic reconstruction picture, instead of the charge transfer of half of an electron in the case of a sufficiently thick stoichiometric LaAlO3, a LaAlO3 film thickness dependence is expected as well as a linear dependence on stoichiometry. Our experimental results on carrier densities in 10 nm-thick LaAl1 +yO3(1 +0.5y) films agree quantitatively with the theoretical expectations, lending a strong support for the electronic reconstruction mechanism. This material is based upon work supported by the U.S. Department of Energy, Office of Science, under Grant No. DE-SC0004764.

  19. Highly efficient production of hyaluronic acid by Streptococcus zooepidemicus R42 derived from heterologous expression of bacterial haemoglobin and mutant selection.

    PubMed

    Lu, J F; Zhu, Y; Sun, H L; Liang, S; Leng, F F; Li, H Y

    2016-04-01

    During Streptococcus zooepidemicus fermentation, most carbon sources are used to synthesize lactic acid, which can inhibit strain growth and hyaluronic acid production. Here, we expressed bacterial haemoglobin (Vhb) in Strep. zooepidemicus. Due to highly efficient oxygen use, only 15·26 g l(-1) lactic acid was produced, which is 0·73 times the quantity produced by the control strain. Compared with the control strain (1·61 g l(-1) ), hyaluronic acid (HA) production in this strain did not substantially increase, only to 2·16 g l(-1) . Next, we used a series of N-methyl-N'-nitro-N-nitroso-guanidine (NTG) treatments and selection programmes. Finally, we generated a hyaluronidase-negative and rifampin-resistant mutant strain that produces high levels of HA. The optimum carbon concentration for maximum hyaluronic acid production is only 30 g l(-1) of sucrose, which is lower than the control strain (60 g l(-1) ). The oxygen transfer rate coefficient KL a increased significantly to 372 ± 53 h(-1) from 18 ± 4 h(-1) of the control. The optimum carbon source for this strain is 21 g l(-1) of sucrose, 9 g l(-1) of maltose and 5 g l(-1) of glutamic acid. Hyaluronic acid accumulated at 6·7 g l(-1) in the culture broth. However, the molecular weight of HA decreased from 1835 KDa (Control) to 429 kDa. The prepared low-molecular weight HA could function as potential antiangiogenic substances, antiviral and antitumour agents to possibly be used as functional food ingredients. Hyaluronic acid (HA) has been used for a wide range of applications in health, cosmetic and clinical fields. During fermentation of Streptococcus to produce HA, 80-85% of the carbon source is used to produce lactic acid and acetic acid, and only approx. 5 and 10% of the carbon source is used to produce HA and biomass respectively. Here, we expressed bacteria haemoglobin (Vhb) in Streptococcus zooepidemicus, which can dramatically inhibit lactic acid production. After NTG

  20. Systematic study on the discharge product of Pt-based lithium oxygen batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Feng; Xing, Yi; Bi, Xuanxuan

    Lithium oxygen batteries have attracted much attention due to the high theoretical energy density. However, they suffer a large overpotential during oxygen evolution process and thus catalysts play a vital role in the reaction. Here, we systematically explored the influence of Pt-based nanoparticle catalysts on the discharge product Li 2O 2. Because of the superior electrical conductivity and the strong binding with oxygen, Pt-based nanoparticles serve as active sites which are favorable for the growth of toroidal Li 2O 2. We also found that the content and composition of Pt-based nanoparticle catalysts exert a significant influence on the electrochemical performancemore » of lithium oxygen batteries. The discharge products are composed of crystalline Li 2O 2 and oxygen-rich LiO 2 characterized by high-energy X-ray diffraction and Raman. Atomic force microscopy further provides detailed information of the particle size and surface roughness. The loading of Pt catalysts determines the phase and size of Li 2O 2 on the discharged electrode surface. This study will be beneficial for the optimization of Pt-based catalysts used in non-aqueous lithium oxygen batteries.« less

  1. Systematic study on the discharge product of Pt-based lithium oxygen batteries

    NASA Astrophysics Data System (ADS)

    Wu, Feng; Xing, Yi; Bi, Xuanxuan; Yuan, Yifei; Wang, Hsien-Hau; Shahbazian-Yassar, Reza; Li, Li; Chen, Renjie; Lu, Jun; Amine, Khalil

    2016-11-01

    Lithium oxygen batteries have attracted much attention due to the high theoretical energy density. However, they suffer a large overpotential during oxygen evolution process and thus catalysts play a vital role in the reaction. Here, we systematically explored the influence of Pt-based nanoparticle catalysts on the discharge product Li2O2. Because of the superior electrical conductivity and the strong binding with oxygen, Pt-based nanoparticles serve as active sites which are favorable for the growth of toroidal Li2O2. We also found that the content and composition of Pt-based nanoparticle catalysts exert a significant influence on the electrochemical performance of lithium oxygen batteries. The discharge products are composed of crystalline Li2O2 and oxygen-rich LiO2 characterized by high-energy X-ray diffraction and Raman. Atomic force microscopy further provides detailed information of the particle size and surface roughness. The loading of Pt catalysts determines the phase and size of Li2O2 on the discharged electrode surface. This study will be beneficial for the optimization of Pt-based catalysts used in non-aqueous lithium oxygen batteries.

  2. Design concepts for hot carrier-based detectors and energy converters in the near ultraviolet and infrared

    NASA Astrophysics Data System (ADS)

    Gong, Tao; Krayer, Lisa; Munday, Jeremy N.

    2016-10-01

    Semiconductor materials are well suited for power conversion when the incident photon energy is slightly larger than the bandgap energy of the semiconductor. However, for photons with energy significantly greater than the bandgap energy, power conversion efficiencies are low. Further, for photons with energy below the bandgap energy, the absence of absorption results in no power generation. Here, we describe photon detection and power conversion of both high- and low-energy photons using hot carrier effects. For the absorption of high-energy photons, excited electrons and holes have excess kinetic energy that is typically lost through thermalization processes between the carriers and the lattice. However, collection of hot carriers before thermalization allows for reduced power loss. Devices utilizing plasmonic nanostructures or simple three-layer stacks (transparent conductor-insulator-metal) can be used to generate and collect these hot carriers. Alternatively, hot carrier collection from sub-bandgap photons can be possible by forming a Schottky junction with an absorbing metal so that hot carriers generated in the metal can be injected across the semiconductor-metal interface. Such structures enable near-IR detection based on sub-bandgap photon absorption. Further, utilization and optimization of localized surface plasmon resonances can increase optical absorption and hot carrier generation (through plasmon decay). Combining these concepts, hot carrier generation and collection can be exploited over a large range of incident wavelengths spanning the UV, visible, and IR.

  3. Meat and cancer: haemoglobin and haemin in a low-calcium diet promote colorectal carcinogenesis at the aberrant crypt stage in rats

    PubMed Central

    Pierre, Fabrice; Taché, Sylviane; Petit, Claude R; Van Der Meer, Roelof; Corpet, Denis E

    2003-01-01

    High intake of red meat, but not of white meat, is associated with an increased risk of colon cancer. However, red meat does not promote cancer in rodents. Haemin, added to low-calcium diets, increases colonic proliferation, and haemoglobin, added to high-fat diets, increases the colon tumour incidence in rats, an effect possibly due to peroxyl radicals. We thus speculated that haem might be the promoting agent in meat, and that prevention strategies could use calcium and antioxidants. These hypotheses were tested in rats at the aberrant crypt foci (ACF) stage at 100 days. F344 rats (n=124) were given an injection of azoxymethane and were then randomised to 11 groups fed with low-calcium (20μmol/g) AIN76-based diets, containing 5% safflower oil. Haemin (0.25, 0.5 and 1.5μmol/g) or haemoglobin (1.5 and 3 μmol haem/g) was added to five experimental diets, compared to a control diet without haem. Three other high-haemin diets (1.5μmol/g) were supplemented with calcium (250μmol/g), antioxidant butylated hydroxyanisole and rutin (0.05% each), and olive oil, which replaced safflower oil. Faecal water was assayed for lipid peroxidation by thiobarbituric acid reactive substances (TBARs) test, and for cytolytic activity. Haemin strikingly increased the ACF size, dose-dependently, from 2.6 to 11.4 crypts/ACF (all p<0.001). The high-haemin diet also increased the number of ACF per colon (p<0.001). Promotion was associated with increased faecal water TBARs and cytotoxicity. Calcium, olive oil, and antioxidants each inhibited the haemin-induced ACF promotion, and normalised the faecal TBARs and cytotoxicity. The haemoglobin diets increased the number of ACF and faecal TBARs, but not the ACF size or the faecal cytotoxicity. In conclusion, dietary haemin is the most potent known ACF promoter. Haemoglobin is also a potent promoter of colorectal carcinogenesis. The results suggest that myoglobin in red meat could promote colon cancer. Diets high in calcium, or in oxidation

  4. Effect of dissolved oxygen on nitrate removal using polycaprolactone as an organic carbon source and biofilm carrier in fixed-film denitrifying reactors.

    PubMed

    Luo, Guozhi; Xu, Guimei; Gao, Jinfang; Tan, Hongxin

    2016-05-01

    Nitrate-nitrogen (NO3(-)-N) always accumulates in commercial recirculating aquaculture systems (RASs) with aerobic nitrification units. The ability to reduce NO3(-)-N consistently and confidently could help RASs to become more sustainable. The rich dissolved oxygen (DO) content and sensitive organisms stocked in RASs increase the difficulty of denitrifying technology. A denitrifying process using biologically degradable polymers as an organic carbon source and biofilm carrier was proposed because of its space-efficient nature and strong ability to remove NO3(-)-N from RASs. The effect of dissolved oxygen (DO) levels on heterotrophic denitrification in fixed-film reactors filled with polycaprolactone (PCL) was explored in the current experiment. DO conditions in the influent of the denitrifying reactors were set up as follows: the anoxic treatment group (Group A, average DO concentration of 0.28±0.05mg/L), the low-oxygen treatment DO group (Group B, average DO concentration of 2.50±0.24mg/L) and the aerated treatment group (Group C, average DO concentration of 5.63±0.57mg/L). Feeding with 200mg/L of NO3(-)-N, the NO3(-)-N removal rates were 1.53, 1.60 and 1.42kg/m(3) PCL/day in Groups A, B and C, respectively. No significant difference in NO3(-)-N removal rates was observed among the three treatments. It was concluded that the inhibitory effects of DO concentrations lower than 6mg/L on heterotrophic denitrification in the fixed-film reactors filled with PCL can be mitigated. Copyright © 2015. Published by Elsevier B.V.

  5. An assessment of envelope-based demodulation in case of proximity of carrier and modulation frequencies

    NASA Astrophysics Data System (ADS)

    Shahriar, Md Rifat; Borghesani, Pietro; Randall, R. B.; Tan, Andy C. C.

    2017-11-01

    Demodulation is a necessary step in the field of diagnostics to reveal faults whose signatures appear as an amplitude and/or frequency modulation. The Hilbert transform has conventionally been used for the calculation of the analytic signal required in the demodulation process. However, the carrier and modulation frequencies must meet the conditions set by the Bedrosian identity for the Hilbert transform to be applicable for demodulation. This condition, basically requiring the carrier frequency to be sufficiently higher than the frequency of the modulation harmonics, is usually satisfied in many traditional diagnostic applications (e.g. vibration analysis of gear and bearing faults) due to the order-of-magnitude ratio between the carrier and modulation frequency. However, the diversification of the diagnostic approaches and applications shows cases (e.g. electrical signature analysis-based diagnostics) where the carrier frequency is in close proximity to the modulation frequency, thus challenging the applicability of the Bedrosian theorem. This work presents an analytic study to quantify the error introduced by the Hilbert transform-based demodulation when the Bedrosian identity is not satisfied and proposes a mitigation strategy to combat the error. An experimental study is also carried out to verify the analytical results. The outcome of the error analysis sets a confidence limit on the estimated modulation (both shape and magnitude) achieved through the Hilbert transform-based demodulation in case of violated Bedrosian theorem. However, the proposed mitigation strategy is found effective in combating the demodulation error aroused in this scenario, thus extending applicability of the Hilbert transform-based demodulation.

  6. Estimation of blood haemoglobin concentration using the HemoCue during caesarean section: the effect of sampling site.

    PubMed

    Richards, N A; Boyce, H; Yentis, S M

    2010-01-01

    Haemoglobin concentration measured using the HemoCue is accurate for capillary and venous/arterial blood, provided the recommended sampling method is strictly observed. Analysis of blood, particularly of capillary samples, using the HemoCue is useful during caesarean section. The toe might be preferred to the thumb since it is numb during neuraxial anaesthesia, but whether sampling at either site is accurate in this situation, given the cardiovascular effects of anaesthesia and pregnancy, is not known. We aimed to compare haemoglobin values measured in venous and capillary samples (toe and thumb) during caesarean section under neuraxial anaesthesia. Fifty healthy women having caesarean section under spinal or combined spinal-epidural anaesthesia were included. At the end of surgery, the great toe and thumb (non-i.v. fluid side) were lanced as recommended for a HemoCue reading. A venous blood sample (non-i.v. fluid side) was also taken and sent for formal laboratory measurement and tested with the HemoCue. Bland-Altman analysis was applied to the haemoglobin values. Bias (mean difference) and precision +/- 2 SD were respectively 0.2 +/-1.6 for laboratory vs. toe, 0.1 +/-1.8 for laboratory vs. thumb, and 0.2 +/-1.6 laboratory vs. venous. Our results suggest that in terms of accuracy, the two sites are equally suitable for use during caesarean section under neuraxial anaesthesia. Copyright 2009 Elsevier Ltd. All rights reserved.

  7. The effects of age on associations between markers of HIV progression and markers of metabolic function including albumin, haemoglobin and lipid concentrations.

    PubMed

    Samuel, M; Jose, S; Winston, A; Nelson, M; Johnson, M; Chadwick, D; Fisher, M; Leen, C; Gompels, M; Gilson, R; Post, F A; Hay, P; Sabin, C A

    2014-05-01

    We investigated whether age modified associations between markers of HIV progression, CD4 T lymphocyte count and HIV RNA viral load (VL), and the following markers of metabolic function: albumin, haemoglobin, high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C) and total cholesterol (TC). A retrospective analysis of data from the United Kingdom Collaborative HIV Cohort was carried out. Analyses were limited to antiretroviral-naïve subjects to focus on the impact of HIV disease itself. A total of 16670 subjects were included in the analysis. Multilevel linear regression models assessed associations between CD4 count/VL and each of the outcomes. Statistical tests for interactions assessed whether associations differed among age groups. After adjustment for gender and ethnicity, there was evidence that lower CD4 count and higher VL were associated with lower TC, LDL-C, haemoglobin and albumin concentrations but higher triglyceride concentrations. Age modified associations between CD4 count and albumin (P < 0.001) and haemoglobin (P = 0.001), but not between CD4 count and HDL-C, LDL-C and TC, or VL and any outcome. Among participants aged < 30, 30-50 and > 50 years, a 50 cells/μL lower CD4 count correlated with a 2.4 [95% confidence interval (CI) 1.7-3.0], 3.6 (95% CI 3.2-4.0) and 5.1 (95% CI 4.0-6.1) g/L lower haemoglobin concentration and a 0.09 (95% CI 0.07-0.11), 0.12 (95% CI 0.11-0.13) and 0.16 (95% CI 0.13-0.19) g/L lower albumin concentration, respectively. We present evidence that age modifies associations between CD4 count and plasma albumin and haemoglobin levels. A given reduction in CD4 count was associated with a greater reduction in haemoglobin and albumin concentrations among older people living with HIV. These findings increase our understanding of how the metabolic impact of HIV is influenced by age. © 2013 The Authors. HIV Medicine published by John Wiley & Sons Ltd on behalf of British HIV Association.

  8. Diagnosing anaemia in pregnancy in rural clinics: assessing the potential of the Haemoglobin Colour Scale.

    PubMed Central

    van den Broek, N. R.; Ntonya, C.; Mhango, E.; White, S. A.

    1999-01-01

    Anaemia in pregnancy is a common and severe problem in many developing countries. Because of lack of resources and staff motivation, screening for anaemia is often solely by clinical examination of the conjunctiva or is not carried out at all. A new colour scale for the estimation of haemoglobin concentration has been developed by WHO. The present study compares the results obtained using the new colour scale on 729 women visiting rural antenatal clinics in Malawi with those obtained by HemoCue haemoglobinometer and electronic Coulter Counter and with the assessment of anaemia by clinical examination of the conjunctiva. Sensitivity using the colour scale was consistently better than for conjunctival inspection alone and interobserver agreement and agreement with Coulter Counter measurements was good. The Haemoglobin Colour Scale is simple to use, well accepted, cheap and gives immediate results. It shows considerable potential for use in screening for anaemia in antenatal clinics in settings where resources are limited. PMID:10063656

  9. Diagnosing anaemia in pregnancy in rural clinics: assessing the potential of the Haemoglobin Colour Scale.

    PubMed

    van den Broek, N R; Ntonya, C; Mhango, E; White, S A

    1999-01-01

    Anaemia in pregnancy is a common and severe problem in many developing countries. Because of lack of resources and staff motivation, screening for anaemia is often solely by clinical examination of the conjunctiva or is not carried out at all. A new colour scale for the estimation of haemoglobin concentration has been developed by WHO. The present study compares the results obtained using the new colour scale on 729 women visiting rural antenatal clinics in Malawi with those obtained by HemoCue haemoglobinometer and electronic Coulter Counter and with the assessment of anaemia by clinical examination of the conjunctiva. Sensitivity using the colour scale was consistently better than for conjunctival inspection alone and interobserver agreement and agreement with Coulter Counter measurements was good. The Haemoglobin Colour Scale is simple to use, well accepted, cheap and gives immediate results. It shows considerable potential for use in screening for anaemia in antenatal clinics in settings where resources are limited.

  10. Biosimilar epoetin alfa increases haemoglobin levels and brings cognitive and socio-relational benefits to elderly transfusion-dependent multiple myeloma patients: results from a pilot study.

    PubMed

    Castelli, Roberto; Sciara, Simona; Lambertenghi Deliliers, Giorgio; Pantaleo, Giuseppe

    2017-05-01

    Anaemia is a complication reported in up to 70% of the multiple myeloma patients (MM), with remarkable clinical, cognitive and socio-relational consequences. Anaemia relates to the course of MM, normalizing in patients during remission and reappearing in relapsing/non-responding patients. In a pilot study with 31 patients with MM and transfusion-dependent anaemia, we evaluated the effects of Binocrit (biosimilar epoetin alfa) on transfusions, haemoglobin levels, mental status (mini-mental state evaluation) and the patients' social-relational functioning and quality of life (QoL). Within a 12-week interval, patients received 40.000 U Binocrit once a week. Binocrit significantly decreased the incidence of transfusion, regardless of the patients' transfusion history, and significantly increased haemoglobin levels (before-and-after-treatment median haemoglobin values = 8.20 vs. 9.40 g/dl, respectively; Wilcoxon Z test, p < .001). A comparatively greater increment in haemoglobin levels among patients who responded to first vs. additional lines of chemotherapy was also observed. Importantly, we additionally found moderate-to-strong positive associations between increments in haemoglobin levels and corresponding increments both in psychological well-being and QoL (FACT-An scores) and the patients' cognitive status (mini-mental state evaluation scores). After statistically controlling for possible concurrent benefits of anti-myeloma therapy, increments in haemoglobin levels clearly predicted both increments in socio-relational FACT-An scores (Spearman's rho = 0.60, p < .001) and in cognitive functioning scores (Spearman's rho = 0.49, p < .006). Binocrit thus appears as an effective, well-tolerated agent for the management of myeloma anaemia, whose documented benefits include amelioration of anaemia, reduction in transfusion, and improvements in the patients' social-relational functioning and cognitive well-being.

  11. Studying effect of carrier fluid viscosity in magnetite based ferrofluids using optical tweezers

    NASA Astrophysics Data System (ADS)

    Savitha, S.; Iyengar, Shruthi S.; Ananthamurthy, Sharath; Bhattacharya, Sarbari

    2018-02-01

    Ferrofluids with varying viscosities of carrier fluids have been prepared with magnetite (Fe3O4) nanoparticles. The nanoparticles were synthesized by chemical co-precipitation and characterized using X-Ray Diffraction (XRD) and Field Emission Scanning Electron Microscopy (FESEM). They were found to be nearly spherical in shape with an almost uniform size of 13nm. The superparamagnetic nature of the water based ferrofluids at room temperature was established by SQUID magnetometry. Dynamic light scattering (DLS) was carried out to establish the size of the nanoparticle clusters in the ferrofluids synthesized. The results indicate an increase in cluster size with increase in carrier fluid viscosity. This is supported by results from Raman Spectroscopy. A further attempt to characterise these ferrofluids was made by studying the behaviour of well characterised non-magnetic micron sized probes that are optically trapped while suspended in the ferrofluid. An increase in carrier fluid viscosity results in a decrease in corner frequency when only the carrier fluid is used as the suspending medium. When the magnetic component is also present the corner frequency is higher than with just the carrier fluid. This relative increase happens at all laser powers at the trapping plane. This trend is also found to be independent of the size and material of the probe particle. Comparisons of various parameters that influence optical trapping lead us to believe that the enhancement could be due to a directed motion of the magnetic clusters in the presence of an optical trap.

  12. 49 CFR 1139.21 - Study carriers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and/or charges. (b) To corroborate the selection of the above study carriers, and to provide a data base for a continuing evaluation of the validity and usefulness of those carriers as a study group... A, Class I Participating Carriers' Revenue Data. [42 FR 40860, Aug. 12, 1977. Redesignated at 47 FR...

  13. 49 CFR 1139.21 - Study carriers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and/or charges. (b) To corroborate the selection of the above study carriers, and to provide a data base for a continuing evaluation of the validity and usefulness of those carriers as a study group... A, Class I Participating Carriers' Revenue Data. [42 FR 40860, Aug. 12, 1977. Redesignated at 47 FR...

  14. 49 CFR 1139.21 - Study carriers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... and/or charges. (b) To corroborate the selection of the above study carriers, and to provide a data base for a continuing evaluation of the validity and usefulness of those carriers as a study group... A, Class I Participating Carriers' Revenue Data. [42 FR 40860, Aug. 12, 1977. Redesignated at 47 FR...

  15. Carrier-phase time transfer.

    PubMed

    Larson, K M; Levine, J

    1999-01-01

    We have conducted several time-transfer experiments using the phase of the GPS carrier rather than the code, as is done in current GPS-based time-transfer systems. Atomic clocks were connected to geodetic GPS receivers; we then used the GPS carrier-phase observations to estimate relative clock behavior at 6-minute intervals. GPS carrier-phase time transfer is more than an order of magnitude more precise than GPS common view time transfer and agrees, within the experimental uncertainty, with two-way satellite time-transfer measurements for a 2400 km baseline. GPS carrier-phase time transfer has a stability of 100 ps, which translates into a frequency uncertainty of about two parts in 10(-15) for an average time of 1 day.

  16. Biceps brachii muscle oxygenation in electrical muscle stimulation.

    PubMed

    Muthalib, Makii; Jubeau, Marc; Millet, Guillaume Y; Maffiuletti, Nicola A; Ferrari, Marco; Nosaka, Kazunori

    2010-09-01

    The purpose of this study was to compare between electrical muscle stimulation (EMS) and maximal voluntary (VOL) isometric contractions of the elbow flexors for changes in biceps brachii muscle oxygenation (tissue oxygenation index, TOI) and haemodynamics (total haemoglobin volume, tHb = oxygenated-Hb + deoxygenated-Hb) determined by near-infrared spectroscopy (NIRS). The biceps brachii muscle of 10 healthy men (23-39 years) was electrically stimulated at high frequency (75 Hz) via surface electrodes to evoke 50 intermittent (4-s contraction, 15-s relaxation) isometric contractions at maximum tolerated current level (EMS session). The contralateral arm performed 50 intermittent (4-s contraction, 15-s relaxation) maximal voluntary isometric contractions (VOL session) in a counterbalanced order separated by 2-3 weeks. Results indicated that although the torque produced during EMS was approximately 50% of VOL (P<0.05), there was no significant difference in the changes in TOI amplitude or TOI slope between EMS and VOL over the 50 contractions. However, the TOI amplitude divided by peak torque was approximately 50% lower for EMS than VOL (P<0.05), which indicates EMS was less efficient than VOL. This seems likely because of the difference in the muscles involved in the force production between conditions. Mean decrease in tHb amplitude during the contraction phases was significantly (P<0.05) greater for EMS than VOL from the 10th contraction onwards, suggesting that the muscle blood volume was lower in EMS than VOL. It is concluded that local oxygen demand of the biceps brachii sampled by NIRS is similar between VOL and EMS.

  17. Diagnostic applications of newborn screening for α-thalassaemias, haemoglobins E and H disorders using isoelectric focusing on dry blood spots.

    PubMed

    Jindatanmanusan, Punyanuch; Riolueang, Suchada; Glomglao, Waraporn; Sukontharangsri, Yaowapa; Chamnanvanakij, Sangkae; Torcharus, Kitti; Viprakasit, Vip

    2014-03-01

    Neonatal screening for haemoglobin (Hb) disorders is a standard of care in several developed countries with the main objective to detect Hb S. Such practice has not been established in Thailand where α-thalassaemia and haemoglobin E (Hb E) are highly prevalent. Early identification of thalassaemias could be helpful and strengthen the programme for prevention and control for severe thalassaemias. Data from isoelectric focusing (IEF) and Isoscan® for detecting types and amount (%) of each haemoglobin in 350 newborn's dried blood spots were analysed and compared with the comprehensive genotype analysis by DNA studies as a gold standard. Based on genetic profiles, there were 10 different categories: (1) normal (n = 227), (2) α(+)-thalassaemia trait (n = 14), (3) α(0)-thalassaemia trait (n = 13), (4) β(0)-thalassaemia trait (n = 7), (5) Hb E trait (n = 72), (6) Hb E trait with α(0)-thalassaemia or homozygous α(+)-thalassaemia (n = 5), (7) Hb E trait with α(+)-thalassaemia trait (n = 5), (8) homozygous Hb E (n = 3), (9) homozygous Hb E with α(0)-thalassaemia trait (n = 1) and (10) Hb H disease (n = 3). The presence of Hb Bart's and Hb E were used to identify cases with α-thalassaemia and Hb E, respectively. We set 0.25% of Hb Bart's and 1.5% of Hb E as a cut-off level to detect α(+)-thalassaemia trait (sensitivity 92.86% and specificity 74.0%) and Hb E trait with 100% of both sensitivity and specificity for IEF diagnosis. Although molecular diagnosis seems to be better for definitive diagnosis of thalassaemia syndromes at birth, however, using our reference range described herein, IEF can be applied in a resource-limiting setting with acceptable reliability.

  18. Self-care activities and glycated haemoglobin in Iranian patients with type 2 diabetes: can coping styles and social support have a buffering role?

    PubMed

    Shayeghian, Zeinab; Aguilar-Vafaie, Maria E; Besharat, Mohammad Ali; Amiri, Parisa; Parvin, Mahmoud; Gillani, Kobra Roohi; Hassanabadi, Hamidreza

    2015-01-01

    Diabetes self-care is a key element in the overall management of diabetes. However, the importance of psychosocial factors for successful disease management is under investigated. This study aimed at exploring the role of coping styles and social support in the relationship between self-care activities and glycated haemoglobin in patients with type 2 diabetes. One hundred adults (60% female, aged 40-70 years) with type 2 diabetes completed questionnaires assessing self-care activities, coping styles and social support. In addition, a blood test was performed to obtain glycated haemoglobin levels. Result showed significant relationships of glycated haemoglobin with self-care activities, coping styles and social support. Regression analysis indicated that social support had a moderating role on the relationship between self-care activities and glycated haemoglobin, such that, at very high levels of social support the association, between Self-Care and HbA1c disappears. Findings indicate that health care providers, within the context of the Iranian social and cultural situation, should pay more attention to psychosocial factors when addressing self-care activities. Delineation of the role of coping styles and social support might be useful for identifying patients in need of particular counselling and support for improving self-care activities and HbA1c levels.

  19. Subcellular Carrier-Based Optical Ion-Selective Nanosensors

    PubMed Central

    Carregal-Romero, Susana; Montenegro, Jose-Maria; Parak, Wolfgang J.; Rivera_Gil, Pilar

    2012-01-01

    In this review, two carrier systems based on nanotechnology for real-time sensing of biologically relevant analytes (ions or other biological molecules) inside cells in a non-invasive way are discussed. One system is based on inorganic nanoparticles with an organic coating, whereas the second system is based on organic microcapsules. The sensor molecules presented within this work use an optical read-out. Due to the different physicochemical properties, both sensors show distinctive geometries that directly affect their internalization patterns. The nanoparticles carry the sensor molecule attached to their surfaces whereas the microcapsules encapsulate the sensor within their cavities. Their different size (nano and micro) enable each sensors to locate in different cellular regions. For example, the nanoparticles are mostly found in endolysosomal compartments but the microcapsules are rather found in phagolysosomal vesicles. Thus, allowing creating a tool of sensors that sense differently. Both sensor systems enable to measure ratiometrically however, only the microcapsules have the unique ability of multiplexing. At the end, an outlook on how more sophisticated sensors can be created by confining the nano-scaled sensors within the microcapsules will be given. PMID:22557969

  20. Manganese and iron as oxygen carriers to anoxie estuarine sediment

    NASA Astrophysics Data System (ADS)

    Brayner, F. M. M.; Matvienko, B.

    2003-05-01

    We studied the concentration of a series of transition metals including Mn and Fe in an estuarine fishpond. The pond is situated at latitude 8°10'S and longitude 34°55'W, in the Capibaribe River estuary, within the Recife city boundaries, which is located in Pernambuco, a state of the Brazilian Northeast Pond area is 1.5 ha and it bas a 0.5 m depth. It is separated from the river by dikes. Water temperature at 28° C is stable throughout the year. Light breezes keep the water aerated, but intense ongoing decomposition makes the sediment anoxie. The area, originally of mangrove type, has been changed by antropic action on its fauna and vegetation. The study focuses on changes in behaviour of heavy metals. Samples of bottom sediments wore collected by Eckman dredge sediment sampler and total metal concentration was determined by the lithium borate fusion method. Water, recent sediment, and consolidated sediment were examined in this fishpond where Mn and Fe are brought in periodically by water and then gradually go into the sediment at respective rates of 10.52 and 1332 mg m^{-2}a^{-1}. Strong bioturbation re-suspends sediment while simultaneously re-dissolution of these ions is going on fhrough reduction in the anoxie sédiment. As soluble species these ions migrate from sediment to water and are there continually oxidized by dissolved oxygen, becoming insoluble. With their precipitation, chemically bound oxygen is carried down to the sediment, constituting a parallel channel of transport in addition to migration into the sediment bydiffusion of the oxygen dissolved in the water. The estimated flow rates are 3.25 and 76 mg O2 m^{-2}a^{-1} due to Mn and Fe respectively. The rates were established using natural silicon as a tracer.

  1. A Pilot Study of Peritoneal Perfusion with a Novel Hemoglobin Based Oxygen Carrier in Swine (Sus scrofa)

    DTIC Science & Technology

    2016-10-12

    has a high rate of complications, obliges systemic anticoagulation, and requires a significant level of logistics support as well as expertise. In...the endotracheal tube was clamped, ceasing gas exchange in the lung. Arterial blood gases and time to death were then recorded. No differences were...observed between treatment and control animals in terms of C02, 02 and time to death . Peritoneal gas exchange did not improve oxygenation, ventilation or time to death in this severe model of lung injury.

  2. Silicon Micropore-Based Parallel Plate Membrane Oxygenator.

    PubMed

    Dharia, Ajay; Abada, Emily; Feinberg, Benjamin; Yeager, Torin; Moses, Willieford; Park, Jaehyun; Blaha, Charles; Wright, Nathan; Padilla, Benjamin; Roy, Shuvo

    2018-02-01

    Extracorporeal membrane oxygenation (ECMO) is a life support system that circulates the blood through an oxygenating system to temporarily (days to months) support heart or lung function during cardiopulmonary failure until organ recovery or replacement. Currently, the need for high levels of systemic anticoagulation and the risk for bleeding are main drawbacks of ECMO that can be addressed with a redesigned ECMO system. Our lab has developed an approach using microelectromechanical systems (MEMS) fabrication techniques to create novel gas exchange membranes consisting of a rigid silicon micropore membrane (SμM) support structure bonded to a thin film of gas-permeable polydimethylsiloxane (PDMS). This study details the fabrication process to create silicon membranes with highly uniform micropores that have a high level of pattern fidelity. The oxygen transport across these membranes was tested in a simple water-based bench-top set-up as well in a porcine in vivo model. It was determined that the mass transfer coefficient for the system using SµM-PDMS membranes was 3.03 ± 0.42 mL O 2 min -1 m -2 cm Hg -1 with pure water and 1.71 ± 1.03 mL O 2 min -1 m -2 cm Hg -1 with blood. An analytic model to predict gas transport was developed using data from the bench-top experiments and validated with in vivo testing. This was a proof of concept study showing adequate oxygen transport across a parallel plate SµM-PDMS membrane when used as a membrane oxygenator. This work establishes the tools and the equipoise to develop future generations of silicon micropore membrane oxygenators. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  3. Enhanced thermoelectric properties in bulk nanowire heterostructure-based nanocomposites through minority carrier blocking.

    PubMed

    Yang, Haoran; Bahk, Je-Hyeong; Day, Tristan; Mohammed, Amr M S; Snyder, G Jeffrey; Shakouri, Ali; Wu, Yue

    2015-02-11

    To design superior thermoelectric materials the minority carrier blocking effect in which the unwanted bipolar transport is prevented by the interfacial energy barriers in the heterogeneous nanostructures has been theoretically proposed recently. The theory predicts an enhanced power factor and a reduced bipolar thermal conductivity for materials with a relatively low doping level, which could lead to an improvement in the thermoelectric figure of merit (ZT). Here we show the first experimental demonstration of the minority carrier blocking in lead telluride-silver telluride (PbTe-Ag2Te) nanowire heterostructure-based nanocomposites. The nanocomposites are made by sintering PbTe-Ag2Te nanowire heterostructures produced in a highly scalable solution-phase synthesis. Compared with Ag2Te nanowire-based nanocomposite produced in similar method, the PbTe-Ag2Te nanocomposite containing ∼5 atomic % PbTe exhibits enhanced Seebeck coefficient, reduced thermal conductivity, and ∼40% improved ZT, which can be well explained by the theoretical modeling based on the Boltzmann transport equations when energy barriers for both electrons and holes at the heterostructure interfaces are considered in the calculations. For this p-type PbTe-Ag2Te nanocomposite, the barriers for electrons, that is, minority carriers, are primarily responsible for the ZT enhancement. By extending this approach to other nanostructured systems, it represents a key step toward low-cost solution-processable nanomaterials without heavy doping level for high-performance thermoelectric energy harvesting.

  4. High temperature thermoelectric properties of strontium titanate thin films with oxygen vacancy and niobium doping.

    PubMed

    Kumar, S R Sarath; Barasheed, Abeer Z; Alshareef, H N

    2013-08-14

    We report the evolution of high temperature thermoelectric properties of SrTiO3 thin films doped with Nb and oxygen vacancies. Structure-property relations in this important thermoelectric oxide are elucidated and the variation of transport properties with dopant concentrations is discussed. Oxygen vacancies are incorporated during growth or annealing in Ar/H2 above 800 K. An increase in lattice constant due to the inclusion of Nb and oxygen vacancies is found to result in an increase in carrier density and electrical conductivity with simultaneous decrease in carrier effective mass and Seebeck coefficient. The lattice thermal conductivity at 300 K is found to be 2.22 W m(-1) K(-1), and the estimated figure of merit is 0.29 at 1000 K.

  5. Study on efficiency droop in InGaN/GaN light-emitting diodes based on differential carrier lifetime analysis

    NASA Astrophysics Data System (ADS)

    Meng, Xiao; Wang, Lai; Hao, Zhibiao; Luo, Yi; Sun, Changzheng; Han, Yanjun; Xiong, Bing; Wang, Jian; Li, Hongtao

    2016-01-01

    Efficiency droop is currently one of the most popular research problems for GaN-based light-emitting diodes (LEDs). In this work, a differential carrier lifetime measurement system is optimized to accurately determine carrier lifetimes (τ) of blue and green LEDs under different injection current (I). By fitting the τ-I curves and the efficiency droop curves of the LEDs according to the ABC carrier rate equation model, the impact of Auger recombination and carrier leakage on efficiency droop can be characterized simultaneously. For the samples used in this work, it is found that the experimental τ-I curves cannot be described by Auger recombination alone. Instead, satisfactory fitting results are obtained by taking both carrier leakage and carriers delocalization into account, which implies carrier leakage plays a more significant role in efficiency droop at high injection level.

  6. Growth and Properties of Oxygen and Ion Doped BISMUTH(2) STRONTIUM(2) Calcium COPPER(2) Oxygen (8+DELTA) Single Crystals

    NASA Astrophysics Data System (ADS)

    Mitzi, David Brian

    1990-01-01

    A directional solidification method for growing large single crystals in the Bi_2Sr _2CaCu_2O _{8+delta} system is reported. Ion substitutions, with replacement of La for Sr and Y for Ca, as well as oxygen doping in these crystals has been explored. Ion doping results in little change of the superconducting transition for substitution levels below 20-25% (as a result of simultaneous oxygen intercalation), while beyond this level, the Meissner signal broadens and the low temperature Meissner signal decreases. Microprobe analysis and x-ray diffraction performed on these more highly substituted single crystals, provides evidence for inhomogeneity and phase segregation into regions of distinct composition. Annealing unsubstituted crystals in increasing partial pressures of oxygen reversibly depresses the superconducting transition temperature from 90K (as made) to 77K (oxygen pressure annealed) while the Hall concentrations increase from n = 3.1(3) times 10 ^{21} cm^{ -3} (0.34 holes/Cu site) to 4.6(3) times 10^{21} cm^{-3} (0.50 holes/Cu site). Further suppression of T_{c} to 72K is possible by annealing in oxygen pressures up to 100atm. No degradation of the Meissner transition or other indications of inhomogeneity or phase segregation with doping are noted, suggesting that oxygen doped Bi_2Sr _2CaCu_2O _{8+delta} is a suitable system for pursuing doping studies. The decrease in T _{c} with concentration for 0.34 <=q n <=q 0.50 indicates that a high carrier concentration regime exists where T_{c} decreases with n and suggests that this decrease does not arise from material inhomogeneity or other materials problems. The physical properties of these Bi _2Sr_2CaCu _2O_{8+delta} crystals, in this high carrier concentration regime, will be discussed.

  7. Enhanced solubility of piperine using hydrophilic carrier-based potent solid dispersion systems.

    PubMed

    Thenmozhi, Kathavarayan; Yoo, Young Je

    2017-09-01

    Piperine alkaloid, an important constituent of black pepper, exhibits numerous therapeutic properties, whereas its usage as a drug is limited due to its poor solubility in aqueous medium, which leads to poor bioavailability. Herein, a new method has been developed to improve the solubility of this drug based on the development of solid dispersions with improved dissolution rate using hydrophilic carriers such as sorbitol (Sor), polyethylene glycol (PEG) and polyvinyl pyrrolidone K30 (PVP) by solvent method. Physical mixtures of piperine and carriers were also prepared for comparison. The physicochemical properties of the prepared solid dispersions were examined using SEM, TEM, DSC, XRD and FT-IR. In vitro dissolution profile of the solid dispersions was recorded and compared with that of the pure piperine and physical mixtures. The effect of these carriers on the aqueous solubility of piperine has been investigated. The solid dispersions of piperine with Sor, PEG and PVP exhibited superior performance for the dissolution of piperine with a drug release of 70%, 76% and 89%, respectively after 2 h compared to physical mixtures and pure piperine, which could be due to its transformation from crystalline to amorphous form as well as the attachment of hydrophilic carriers to the surface of poorly water-soluble piperine. Results suggest that the piperine solid dispersions prepared with improved in vitro release exhibit potential advantage in delivering poorly water-soluble piperine as an oral supplement.

  8. Oxygen carrier for gas chromatographic analysis of inert gases in propellants

    NASA Technical Reports Server (NTRS)

    Cannon, W. A.

    1972-01-01

    Gas chromatographic determination of small quantities of inert gases in reactive propellants is discussed. Operating conditions used for specific analyses of helium in diborane and nitrogen in oxygen difluoride are presented in tabular form.

  9. Maintenance of Mitochondrial Oxygen Homeostasis by Cosubstrate Compensation

    PubMed Central

    Kueh, Hao Yuan; Niethammer, Philipp; Mitchison, Timothy J.

    2013-01-01

    Mitochondria maintain a constant rate of aerobic respiration over a wide range of oxygen levels. However, the control strategies underlying oxygen homeostasis are still unclear. Using mathematical modeling, we found that the mitochondrial electron transport chain (ETC) responds to oxygen level changes by undergoing compensatory changes in reduced electron carrier levels. This emergent behavior, which we named cosubstrate compensation (CSC), enables the ETC to maintain homeostasis over a wide of oxygen levels. When performing CSC, our ETC models recapitulated a classic scaling relationship discovered by Chance [Chance B (1965) J. Gen. Physiol. 49:163-165] relating the extent of oxygen homeostasis to the kinetics of mitochondrial electron transport. Analysis of an in silico mitochondrial respiratory system further showed evidence that CSC constitutes the dominant control strategy for mitochondrial oxygen homeostasis during active respiration. Our findings indicate that CSC constitutes a robust control strategy for homeostasis and adaptation in cellular biochemical networks. PMID:23528093

  10. Improving the Charge Carrier Transport and Suppressing Recombination of Soluble Squaraine-Based Solar Cells via Parallel-Like Structure

    PubMed Central

    Zhu, Youqin; Liu, Jingli; Zhao, Jiao; Li, Yang; Qiao, Bo; Song, Dandan; Huang, Yan; Xu, Zheng; Zhao, Suling; Xu, Xurong

    2018-01-01

    Small molecule organic solar cells (SMOSCs) have attracted extensive attention in recent years. Squaraine (SQ) is a kind of small molecule material for potential use in high-efficiency devices, because of its high extinction coefficient and low-cost synthesis. However, the charge carrier mobility of SQ-based film is much lower than other effective materials, which leads to the pretty low fill factor (FF). In this study, we improve the performance of SQ derivative-based solar cells by incorporating PCDTBT into LQ-51/PC71BM host binary blend film. The incorporation of PCDTBT can not only increase the photon harvesting, but also provide an additional hole transport pathway. Through the charge carrier mobility and transient photovoltage measurement, we find that the hole mobility and charge carrier lifetime increase in the ternary system. Also, we carefully demonstrate that the charge carrier transport follows a parallel-like behavior. PMID:29747394

  11. Gallic Acid as an Oxygen Scavenger in Bio-Based Multilayer Packaging Films

    PubMed Central

    Pant, Astrid F.; Sängerlaub, Sven; Müller, Kajetan

    2017-01-01

    Oxygen scavengers are used in food packaging to protect oxygen-sensitive food products. A mixture of gallic acid (GA) and sodium carbonate was used as an oxygen scavenger (OSc) in bio-based multilayer packaging films produced in a three-step process: compounding, flat film extrusion, and lamination. We investigated the film surface color as well as oxygen absorption at different relative humidities (RHs) and temperatures, and compared the oxygen absorption of OSc powder, monolayer films, and multilayer films. The films were initially brownish-red in color but changed to greenish-black during oxygen absorption under humid conditions. We observed a maximum absorption capacity of 447 mg O2/g GA at 21 °C and 100% RH. The incorporation of GA into a polymer matrix reduced the rate of oxygen absorption compared to the GA powder because the polymer acted as a barrier to oxygen and water vapor diffusion. As expected, the temperature had a significant effect on the initial absorption rate of the multilayer films; the corresponding activation energy was 75.4 kJ/mol. Higher RH significantly increased the oxygen absorption rate. These results demonstrate for the first time the production and the properties of a bio-based multilayer packaging film with GA as the oxygen scavenger. Potential applications include the packaging of food products with high water activity (aw > 0.86). PMID:28772849

  12. Gallic Acid as an Oxygen Scavenger in Bio-Based Multilayer Packaging Films.

    PubMed

    Pant, Astrid F; Sängerlaub, Sven; Müller, Kajetan

    2017-05-03

    Oxygen scavengers are used in food packaging to protect oxygen-sensitive food products. A mixture of gallic acid (GA) and sodium carbonate was used as an oxygen scavenger (OSc) in bio-based multilayer packaging films produced in a three-step process: compounding, flat film extrusion, and lamination. We investigated the film surface color as well as oxygen absorption at different relative humidities (RHs) and temperatures, and compared the oxygen absorption of OSc powder, monolayer films, and multilayer films. The films were initially brownish-red in color but changed to greenish-black during oxygen absorption under humid conditions. We observed a maximum absorption capacity of 447 mg O₂/g GA at 21 °C and 100% RH. The incorporation of GA into a polymer matrix reduced the rate of oxygen absorption compared to the GA powder because the polymer acted as a barrier to oxygen and water vapor diffusion. As expected, the temperature had a significant effect on the initial absorption rate of the multilayer films; the corresponding activation energy was 75.4 kJ/mol. Higher RH significantly increased the oxygen absorption rate. These results demonstrate for the first time the production and the properties of a bio-based multilayer packaging film with GA as the oxygen scavenger. Potential applications include the packaging of food products with high water activity (a w > 0.86).

  13. Haemoglobin F Malaysia: α2γ2 1 (NA1) Glycine→Cysteine; 136 Glycine

    PubMed Central

    Eng, Lie-Injo Luan; Kamuzora, H.; Lehmann, H.

    1974-01-01

    Structural studies of an abnormal haemoglobin found in a Chinese newborn but not in her parents, showed it to be a new γ-chain variant, Hb F Malaysia. The first residue of the γ-chain was Cys and not Gly, and the γ-chain was of the type in which residue 136 is Gly and not Ala. Images PMID:4837284

  14. Impact of nutrition education on knowledge and haemoglobin status of hill women in Uttarakhand State of India.

    PubMed

    Upadhyay, S; Kumar, A R; Raghuvanshi, R S; Singh, B B

    2011-12-01

    This study aimed to examine the impact of the use of single vs. combination of media on nutritional knowledge and haemoglobin status of women in a rural hill area in Uttarakhand State, India. Women from three villages were selected randomly and divided into three groups namely, print media group (n = 59), multimedia group (n = 53) and control group (n = 111). The print media group was exposed to nutrition education through the use of calendars on anaemia for 60 days; the multimedia group was given nutrition education through a combination of media including calendars, video films, and group discussions for 60 days. At pre-exposure stage, 62.7% of the women in the print media group, 67.9% of the multimedia group, and 66.7% of the control group had a low nutrition knowledge level. After exposure, the print media group and the multimedia group showed a significant rise in nutrition knowledge, with the multimedia group scoring significantly higher than the print media group. Overall, 69.1% of the women were anaemic with mean haemoglobin concentration of 10.74 +/- 0.86 g/dl. A non-significant rise in mean haemoglobin concentrations in the experimental groups was found at post-exposure stage. Calendars and video films are effective in increasing nutrition knowledge of illiterate hill women. Use of mass media programmes of longer duration should be encouraged to combat the nutritional problems of rural communities.

  15. Investigation of albumin-derived perfluorocarbon-based capsules by holographic optical trapping

    PubMed Central

    Köhler, Jannis; Ruschke, Jegor; Ferenz, Katja Bettina; Esen, Cemal; Kirsch, Michael; Ostendorf, Andreas

    2018-01-01

    Albumin-derived perfluorocarbon-based capsules are promising as artificial oxygen carriers with high solubility. However, these capsules have to be studied further to allow initial human clinical tests. The aim of this paper is to provide and characterize a holographic optical tweezer to enable contactless trapping and moving of individual capsules in an environment that mimics physiological (in vivo) conditions most effectively in order to learn more about the artificial oxygen carrier behavior in blood plasma without recourse to animal experiments. Therefore, the motion behavior of capsules in a ring shaped or vortex beam is analyzed and optimized on account of determination of the optical forces in radial and axial direction. In addition, due to the customization and generation of dynamic phase holograms, the optical tweezer is used for first investigations on the aggregation behavior of the capsules and a statistical evaluation of the bonding in dependency of different capsule sizes is performed. The results show that the optical tweezer is sufficient for studying individual perfluorocarbon-based capsules and provide information about the interaction of these capsules for future use as artificial oxygen carriers. PMID:29552409

  16. A code-aided carrier synchronization algorithm based on improved nonbinary low-density parity-check codes

    NASA Astrophysics Data System (ADS)

    Bai, Cheng-lin; Cheng, Zhi-hui

    2016-09-01

    In order to further improve the carrier synchronization estimation range and accuracy at low signal-to-noise ratio ( SNR), this paper proposes a code-aided carrier synchronization algorithm based on improved nonbinary low-density parity-check (NB-LDPC) codes to study the polarization-division-multiplexing coherent optical orthogonal frequency division multiplexing (PDM-CO-OFDM) system performance in the cases of quadrature phase shift keying (QPSK) and 16 quadrature amplitude modulation (16-QAM) modes. The simulation results indicate that this algorithm can enlarge frequency and phase offset estimation ranges and enhance accuracy of the system greatly, and the bit error rate ( BER) performance of the system is improved effectively compared with that of the system employing traditional NB-LDPC code-aided carrier synchronization algorithm.

  17. Full-duplex radio over fiber link with colorless source-free base station based on single sideband optical mm-wave signal with polarization rotated optical carrier

    NASA Astrophysics Data System (ADS)

    Ma, Jianxin

    2016-07-01

    A full-duplex radio-over fiber (RoF) link scheme based on single sideband (SSB) optical millimeter (mm)-wave signal with polarization-rotated optical carrier is proposed to realize the source-free colorless base station (BS), in which a polarization beam splitter (PBS) is used to abstract part of the optical carrier for conveying the uplink data. Since the optical carrier for the uplink does not bear the downlink signal, no cross-talk from the downlink contaminates the uplink signal. The simulation results demonstrate that both down- and up-links maintain good performance. The mm-wave signal distribution network based on the proposed full duplex fiber link scheme can use the uniform source-free colorless BSs, which makes the access system very simpler.

  18. Post-surgical wound management of pilonidal cysts with a haemoglobin spray: a case series.

    PubMed

    Mustafi, N; Engels, P

    2016-04-01

    Painful acute cysts in the natal cleft or lower back, known as pilonidal sinus disease, are a severe burden to many younger patients. Although surgical intervention is the preferred first line treatment, postsurgical wound healing disturbances are frequently reported due to infection or other complications. Different treatment options of pilonidal cysts have been discussed in the literature, however, no standardised guideline for the postsurgical wound treatment is available. After surgery, a common recommended treatment to patients is rinsing the wound with clean water and dressing with a sterile compress. We present a case series of seven patients with wounds healing by secondary intention after surgical intervention of a pilonidal cyst. The average age of the patients was 40 years old. Of the seven patients, three had developed a wound healing disturbance, one wound had started to develop a fibrin coating and three were in a good condition. The applied wound care regimens comprised appropriate mechanical or autolytic debridement, rinsing with an antimicrobial solution, haemoglobin application, and primary and secondary dressings. In all seven cases a complete wound closure was achieved within an average of 76 days with six out of seven wounds achieving wound closure within 23-98 days. Aesthetic appearance was deemed excellent in five out of seven cases excellent and acceptable in one. Treatment of one case with a sustained healing disturbance did result in wound closure but with a poor aesthetic outcome and an extensive cicatrisation of the new tissue. Based on these results we recommend that to avoid healing disturbances of wounds healing by secondary intention after surgical pilonidal cyst intervention, an adequate wound care regime comprising appropriate wound debridement, rinsing, topically applied haemoglobin and adequate wound dressing is recommendable as early as possible after surgery.

  19. Plentiful magnetic moments in oxygen deficient SrTiO 3

    DOE PAGES

    Ganesh, Panchapakesan; Lopez-Bezanilla, Alejandro; Littlewood, Peter B.

    2015-10-06

    In this research, correlated band theory is employed to investigate the magnetic and electronic properties of different arrangements of oxygen di- and tri-vacancy clusters in SrTiO 3. Hole and electron doping of oxygen deficient SrTiO 3 yields various degrees of magnetization as a result of the interaction between localized magnetic moments at the defect sites. Different kinds of Ti atomic orbital hybridization are described as a function of the doping level and defect geometry. We find that magnetism in SrTiO 3–δ is sensitive to the arrangement of neighbouring vacancy sites, charge carrier density, and vacancy-vacancy interaction. Permanent magnetic moments inmore » the absence of vacancy doping electrons are observed. Our description of the charged clusters of oxygen vacancies widens the previous descriptions of mono- and multi-vacancies and points out the importance of the controlled formation at the atomic level of defects for the realization of transition metal oxide based devices with a desirable magnetic performance.« less

  20. Application of two component biodegradable carriers in a particle-fixed biofilm airlift suspension reactor: development and structure of biofilms.

    PubMed

    Hille, Andrea; He, Mei; Ochmann, Clemens; Neu, Thomas R; Horn, Harald

    2009-01-01

    Two component biodegradable carriers for biofilm airlift suspension (BAS) reactors were investigated with respect to development of biofilm structure and oxygen transport inside the biofilm. The carriers were composed of PHB (polyhydroxybutyrate), which is easily degradable and PCL (caprolactone), which is less easily degradable by heterotrophic microorganisms. Cryosectioning combined with classical light microscopy and CLSM was used to identify the surface structure of the carrier material over a period of 250 days of biofilm cultivation in an airlift reactor. Pores of 50 to several hundred micrometers depth are formed due to the preferred degradation of PHB. Furthermore, microelectrode studies show the transport mechanism for different types of biofilm structures, which were generated under different substrate conditions. At high loading rates, the growth of a rather loosely structured biofilm with high penetration depths of oxygen was found. Strong changes of substrate concentration during fed-batch mode operation of the reactor enhance the growth of filamentous biofilms on the carriers. Mass transport in the outer regions of such biofilms was mainly driven by advection.