Sample records for hand held unit

  1. Maintaining radiation exposures as low as reasonably achievable (ALARA) for dental personnel operating portable hand-held x-ray equipment.

    PubMed

    McGiff, Thomas J; Danforth, Robert A; Herschaft, Edward E

    2012-08-01

    Clinical experience indicates that newly available portable hand-held x-ray units provide advantages compared to traditional fixed properly installed and operated x-ray units in dental radiography. However, concern that hand-held x-ray units produce higher operator doses than fixed x-ray units has caused regulatory agencies to mandate requirements for use of hand-held units that go beyond those recommended by the manufacturer and can discourage the use of this technology. To assess the need for additional requirements, a hand-held x-ray unit and a pair of manikins were used to measure the dose to a simulated operator under two conditions: exposures made according to the manufacturer's recommendations and exposures made according to manufacturer's recommendation except for the removal of the x-ray unit's protective backscatter shield. Dose to the simulated operator was determined using an array of personal dosimeters and a pair of pressurized ion chambers. The results indicate that the dose to an operator of this equipment will be less than 0.6 mSv y⁻¹ if the device is used according to the manufacturer's recommendations. This suggests that doses to properly trained operators of well-designed, hand-held dental x-ray units will be below 1.0 mSv y⁻¹ (2% of the annual occupational dose limit) even if additional no additional operational requirements are established by regulatory agencies. This level of annual dose is similar to those reported as typical dental personnel using fixed x-ray units and appears to satisfy the ALARA principal for this class of occupational exposures.

  2. Hand-Held Self-Maneuvering Unit to be used during EVA on Gemini 4

    NASA Image and Video Library

    1965-06-02

    Hand-Held Self-Maneuvering Unit to be used during extravehicular activity (EVA) on Gemini 4 flight. It is an integral unit that contains its own high pressure metering valves and nozzles required to produce controlled thrust. A camera is mounted on the front of the unit.

  3. Selected developments in laser wire stripping. [cutting insulation from aerospace-type wires and cables

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The operation of mechanical and thermal strippers and the early development of laser wire strippers are reviewed. NASA sponsored development of laser wire stripping for space shuttle includes bench-type strippers as well as an advanced portable hand-held stripper which incorporates a miniaturized carbon dioxide laser and a rotating optics unit with a gas-jet assist and debris exhaust. Drives and controls girdle the wire and slit the remaining slug without manual assistance. This unit can strip wire sizes 26 through 12 gage. A larger-capacity hand-held unit for wire sizes through 1/0 gage was built using a neodynium-doped yttrium aluminum garnet (Nd:YAG) laser. The hand-held units have a flexible umbilical cable to an accompanying cart that carries the power supply, gas supply, cooling unit, and the controls.

  4. Hand held phase-shifting diffraction moire interferometer

    DOEpatents

    Deason, Vance A.; Ward, Michael B.

    1994-01-01

    An interferometer in which a coherent beam of light is generated within a remote case and transmitted to a hand held unit tethered to said remote case, said hand held unit having optical elements for directing a pair of mutually coherent collimated laser beams at a diffraction grating. Data from the secondary or diffracted beams are then transmitted to a separate video and data acquisition system for recording and analysis for load induced deformation or for identification purposes. Means are also provided for shifting the phase of one incident beam relative to the other incident beam and being controlled from within said remote case.

  5. Hand held phase-shifting diffraction Moire interferometer

    DOEpatents

    Deason, V.A.; Ward, M.B.

    1994-09-20

    An interferometer is described in which a coherent beam of light is generated within a remote case and transmitted to a hand held unit tethered to said remote case, said hand held unit having optical elements for directing a pair of mutually coherent collimated laser beams at a diffraction grating. Data from the secondary or diffracted beams are then transmitted to a separate video and data acquisition system for recording and analysis for load induced deformation or for identification purposes. Means are also provided for shifting the phase of one incident beam relative to the other incident beam and being controlled from within said remote case. 4 figs.

  6. Distributing Data from Desktop to Hand-Held Computers

    NASA Technical Reports Server (NTRS)

    Elmore, Jason L.

    2005-01-01

    A system of server and client software formats and redistributes data from commercially available desktop to commercially available hand-held computers via both wired and wireless networks. This software is an inexpensive means of enabling engineers and technicians to gain access to current sensor data while working in locations in which such data would otherwise be inaccessible. The sensor data are first gathered by a data-acquisition server computer, then transmitted via a wired network to a data-distribution computer that executes the server portion of the present software. Data in all sensor channels -- both raw sensor outputs in millivolt units and results of conversion to engineering units -- are made available for distribution. Selected subsets of the data are transmitted to each hand-held computer via the wired and then a wireless network. The selection of the subsets and the choice of the sequences and formats for displaying the data is made by means of a user interface generated by the client portion of the software. The data displayed on the screens of hand-held units can be updated at rates from 1 to

  7. Hand-held cell phone use while driving legislation and observed driver behavior among population sub-groups in the United States.

    PubMed

    Rudisill, Toni M; Zhu, Motao

    2017-05-12

    Cell phone use behaviors are known to vary across demographic sub-groups and geographic locations. This study examined whether universal hand-held calling while driving bans were associated with lower road-side observed hand-held cell phone conversations across drivers of different ages (16-24, 25-59, ≥60 years), sexes, races (White, African American, or other), ruralities (suburban, rural, or urban), and regions (Northeast, Midwest, South, and West). Data from the 2008-2013 National Occupant Protection Use Survey were merged with states' cell phone use while driving legislation. The exposure was presence of a universal hand-held cell phone ban at time of observation. Logistic regression was used to assess the odds of drivers having a hand-held cell phone conversation. Sub-groups differences were assessed using models with interaction terms. When universal hand-held cell phone bans were effective, hand-held cell phone conversations were lower across all driver demographic sub-groups and regions. Sub-group differences existed among the sexes (p-value, <0.0001) and regions (p-value, 0.0003). Compared to states without universal hand-held cell phone bans, the adjusted odds ratio (aOR) of a driver hand-held phone conversation was 0.34 [95% confidence interval (CI): 0.28, 0.41] for females versus 0.47 (CI 0.40, 0.55) for males and 0.31 (CI 0.25, 0.38) for drivers in Western states compared to 0.47 (CI 0.30, 0.72) in the Northeast and 0.50 (CI 0.38, 0.66) in the South. The presence of universal hand-held cell phone bans were associated lower hand-held cell phone conversations across all driver sub-groups and regions. Hand-held phone conversations were particularly lower among female drivers and those from Western states when these bans were in effect. Public health interventions concerning hand-held cell phone use while driving could reasonably target all drivers.

  8. Technology in the College Classroom.

    ERIC Educational Resources Information Center

    Earl, Archie W., Sr.

    An analysis was made of the use of computing tools at the graduate and undergraduate levels in colleges and universities in the United States. Topics ranged from hand-held calculators to the use of main-frame computers and the assessment of the SPSSX, SPSS, LINDO, and MINITAB computer software packages. Hand-held calculators are being increasingly…

  9. Simultaneous hand-held contact color fundus and SD-OCT imaging for pediatric retinal diseases (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Ruggeri, Marco; Hernandez, Victor; De Freitas, Carolina; Relhan, Nidhi; Silgado, Juan; Manns, Fabrice; Parel, Jean-Marie

    2016-03-01

    Hand-held wide-field contact color fundus photography is currently the standard method to acquire diagnostic images of children during examination under anesthesia and in the neonatal intensive care unit. The recent development of portable non-contact hand-held OCT retinal imaging systems has proved that OCT is of tremendous help to complement fundus photography in the management of pediatric patients. Currently, there is no commercial or research system that combines color wide-field digital fundus and OCT imaging in a contact-fashion. The contact of the probe with the cornea has the advantages of reducing motion experienced by the photographer during the imaging and providing fundus and OCT images with wider field of view that includes the periphery of the retina. In this study we produce proof of concept for a contact-type hand-held unit for simultaneous color fundus and OCT live view of the retina of pediatric patients. The front piece of the hand-held unit consists of a contact ophthalmoscopy lens integrating a circular light guide that was recovered from a digital fundus camera for pediatric imaging. The custom-made rear piece consists of the optics to: 1) fold the visible aerial image of the fundus generated by the ophthalmoscopy lens on a miniaturized level board digital color camera; 2) conjugate the eye pupil to the galvanometric scanning mirrors of an OCT delivery system. Wide-field color fundus and OCT images were simultaneously obtained in an eye model and sequentially obtained on the eye of a conscious 25 year-old human subject with healthy retina.

  10. Hand-held indirect calorimeter offers advantages compared with prediction equations, in a group of overweight women, to determine resting energy expenditures and estimated total energy expenditures during research screening.

    PubMed

    Spears, Karen E; Kim, Hyunsook; Behall, Kay M; Conway, Joan M

    2009-05-01

    To compare standardized prediction equations to a hand-held indirect calorimeter in estimating resting energy and total energy requirements in overweight women. Resting energy expenditure (REE) was measured by hand-held indirect calorimeter and calculated by prediction equations Harris-Benedict, Mifflin-St Jeor, World Health Organization/Food and Agriculture Organization/United Nations University (WHO), and Dietary Reference Intakes (DRI). Physical activity level, assessed by questionnaire, was used to estimate total energy expenditure (TEE). Subjects (n=39) were female nonsmokers older than 25 years of age with body mass index more than 25. Repeated measures analysis of variance, Bland-Altman plot, and fitted regression line of difference. A difference within +/-10% of two methods indicated agreement. Significant proportional bias was present between hand-held indirect calorimeter and prediction equations for REE and TEE (P<0.01); prediction equations overestimated at lower values and underestimated at higher values. Mean differences (+/-standard error) for REE and TEE between hand-held indirect calorimeter and Harris-Benedict were -5.98+/-46.7 kcal/day (P=0.90) and 21.40+/-75.7 kcal/day (P=0.78); between hand-held indirect calorimeter and Mifflin-St Jeor were 69.93+/-46.7 kcal/day (P=0.14) and 116.44+/-75.9 kcal/day (P=0.13); between hand-held indirect calorimeter and WHO were -22.03+/-48.4 kcal/day (P=0.65) and -15.8+/-77.9 kcal/day (P=0.84); and between hand-held indirect calorimeter and DRI were 39.65+/-47.4 kcal/day (P=0.41) and 56.36+/-85.5 kcal/day (P=0.51). Less than 50% of predictive equation values were within +/-10% of hand-held indirect calorimeter values, indicating poor agreement. A significant discrepancy between predicted and measured energy expenditure was observed. Further evaluation of hand-held indirect calorimeter research screening is needed.

  11. Hand-Held Model of a Sarcomere to Illustrate the Sliding Filament Mechanism in Muscle Contraction

    ERIC Educational Resources Information Center

    Jittivadhna, Karnyupha; Ruenwongsa, Pintip; Panijpan, Bhinyo

    2009-01-01

    From our teaching of the contractile unit of the striated muscle, we have found limitations in using textbook illustrations of sarcomere structure and its related dynamic molecular physiological details. A hand-held model of a striated muscle sarcomere made from common items has thus been made by us to enhance students' understanding of the…

  12. Digital hand-held temperature monitor

    NASA Astrophysics Data System (ADS)

    Allin, L. V.; Ferrari, I.

    1980-09-01

    A hand-held non-invasive monitoring instrument has been designed, constructed and tested to allow core temperature measurements to be obtained from human subjects who have swallowed a temperature-sensing radio transmitter (radio pill). This instrument uses a simple AM radio for a receiver, digital circuitry to decode the received signal and a four-digit LED module to display the temperature. The unit, which is battery-powered, can be held in one hand while an antenna probe is swept over the abdomen of the subject until a continuously audible signal is generated by a piezoelectric sound source, indicating reception. The digital display then presents the body core temperature in tenths of a degree Celsius.

  13. 75 FR 27504 - Substantial Product Hazard List: Hand-Held Hair Dryers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-17

    ...The Consumer Product Safety Improvement Act of 2008 (``CPSIA''), authorizes the United States Consumer Product Safety Commission (``Commission'') to specify, by rule, for any consumer product or class of consumer products, characteristics whose existence or absence shall be deemed a substantial product hazard under certain circumstances. In this document, the Commission is proposing a rule to determine that any hand-held hair dryer without integral immersion protection presents a substantial product hazard.

  14. Hand-Held EMI Sensor Combined with Inertial Positioning for Cued UXO Discrimination - APG Standardized UXO Test Site

    DTIC Science & Technology

    2013-04-01

    Measurement Tracking System (SAINT) with an advanced hand-held, time-domain electromagnetic sensor (TEM-HH) and document classification performance at...rejecting 77% of the clutter. 15. SUBJECT TERMS EMI, electromagnetic induction, UXO classification, UXO, IMU, inertial measurement unit, 16. SECURITY...U c. THIS PAGE U UU 19b. TELEPHONE NUMBER (include area code) 919-677-1560 Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18

  15. Applications of a hand-held GPS receiver in South American rain forests

    NASA Technical Reports Server (NTRS)

    Baksh, Michael

    1991-01-01

    A hand-held Global Positioning System receiver was used to determine the precise locations of villages, houses, gardens, and other cultural and environmental features in poorly mapped South American rain forests. The Magellan NAV 1000 unit profides extremely accurate latitude and longitude information, but determination of altitude is problematical. Overall, the receiver effectively allows anthropologists to obtain essential locational data useful for categorizing land uses, mapping tribal boundaries, and other applications in regions where environmental conditions are harsh and/or accessibility is difficult.

  16. Noise reduction techniques in the design of a pneumatic-driven hand held power tool

    NASA Astrophysics Data System (ADS)

    Skinner, Christian M.

    2005-09-01

    Pneumatic-driven hand-held power tools generate noise in the workplace. Current legislation in Europe and the USA aims at protecting workers against noise exposure. In the United States, the Occupational Safety and Health Administration (OSHA) requires that employers create a hearing conservation program if the noise exposure exceeds 85 dB(A). In the European Community under the Directive 2003/10/EC, employers are required to provide hearing protection if the noise exposure within the working environment exceeds 80 dB(A) and must require hearing protection to be worn if the noise exposure exceeds 85 dB(A). This paper examines the sources of noise which contribute to the overall noise from a hand-held power tool. A test plan was developed to identify these individual sources of noise and to determine if structure-borne noise or airborne noise is the dominant source relative to the overall noise level. The measurements were performed per International Standards Organization (ISO) 15744. This paper will describe the methodology used to identify the noise sources and reduce the overall noise of a hand-held power tool.

  17. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children.

    PubMed

    Alving, K; Janson, C; Nordvall, L

    2006-04-20

    Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). A total of 71 subjects (6-60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). Success rate was high (> or = 84%) in both devices for both adults and children. The subjects represented a FENO range of 8-147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children. The new hand-held device will enable the introduction of exhaled NO measurements into the primary health care.

  18. Spiral Chip Implantable Radiator and Printed Loop External Receptor for RF Telemetry in Bio-Sensor Systems

    NASA Technical Reports Server (NTRS)

    Simons, Rainee N.; Hall, David G.; Miranda, Felix A.

    2004-01-01

    The paper describes the operation of a patented wireless RF telemetry system, consisting of a bio-MEMS implantable sensor and an external hand held unit, operating over the frequency range of few hundreds of MHz. A MEMS capacitive pressure sensor integrated with a miniature inductor/antenna together constitute the implantable sensor. Signal processing circuits collocated with a printed loop antenna together form the hand held unit, capable of inductively powering and also receiving the telemetry signals from the sensor. The paper in addition, demonstrates a technique to enhance the quality factor and inductance of the inductor in the presence of a lower ground plane and also presents the radiation characteristics of the loop antenna.

  19. Hand held data collection and monitoring system for nuclear facilities

    DOEpatents

    Brayton, D.D.; Scharold, P.G.; Thornton, M.W.; Marquez, D.L.

    1999-01-26

    Apparatus and method is disclosed for a data collection and monitoring system that utilizes a pen based hand held computer unit which has contained therein interaction software that allows the user to review maintenance procedures, collect data, compare data with historical trends and safety limits, and input new information at various collection sites. The system has a means to allow automatic transfer of the collected data to a main computer data base for further review, reporting, and distribution purposes and uploading updated collection and maintenance procedures. The hand held computer has a running to-do list so sample collection and other general tasks, such as housekeeping are automatically scheduled for timely completion. A done list helps users to keep track of all completed tasks. The built-in check list assures that work process will meet the applicable processes and procedures. Users can hand write comments or drawings with an electronic pen that allows the users to directly interface information on the screen. 15 figs.

  20. Hand held data collection and monitoring system for nuclear facilities

    DOEpatents

    Brayton, Darryl D.; Scharold, Paul G.; Thornton, Michael W.; Marquez, Diana L.

    1999-01-01

    Apparatus and method is disclosed for a data collection and monitoring system that utilizes a pen based hand held computer unit which has contained therein interaction software that allows the user to review maintenance procedures, collect data, compare data with historical trends and safety limits, and input new information at various collection sites. The system has a means to allow automatic transfer of the collected data to a main computer data base for further review, reporting, and distribution purposes and uploading updated collection and maintenance procedures. The hand held computer has a running to-do list so sample collection and other general tasks, such as housekeeping are automatically scheduled for timely completion. A done list helps users to keep track of all completed tasks. The built-in check list assures that work process will meet the applicable processes and procedures. Users can hand write comments or drawings with an electronic pen that allows the users to directly interface information on the screen.

  1. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children

    PubMed Central

    Alving, K; Janson, C; Nordvall, L

    2006-01-01

    Background Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). Methods A total of 71 subjects (6–60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). Results Success rate was high (≥ 84%) in both devices for both adults and children. The subjects represented a FENO range of 8–147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. Conclusion The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children. The new hand-held device will enable the introduction of exhaled NO measurements into the primary health care. PMID:16626491

  2. Hand-held triangulation laser profilometer with audio output for blind people Profilométre laser à triangulation tenu en main avec sortie sonare pour non-voyants

    NASA Astrophysics Data System (ADS)

    Farcy, R.; Damaschini, R.

    1998-06-01

    We describe a device currently under industrial development which will give to the blind a means of three-dimensional space perception. It consists of a 350 g hand-held triangulating laser telemeter including electronic parts and batteries, with auditory feedback either inside the apparatus or close to the ear. The microprocessor unit converts in real time the distance measured by the telemeter into a musical note. Scanning the space with an adequate movement of the hand produces musical lines corresponding to the profiles of the environment. We discuss the optical configuration of the system relative to our first year of clinical experimentation.

  3. TEMTADS Adjunct Sensor Systems Hand-Held EMI Sensor for Cued UXO Discrimination (ESTCP MR-200807) and Man-Portable EMI Array for UXO Detection and Discrimination (ESTCP MR-200909)

    DTIC Science & Technology

    2012-04-05

    C la ss ifi ca tio n TY PE D ep th (M ) A zi m ut h (D eg re es ) D ip (D eg re es ) 1 2 3...Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/ 6110 --12-9401 TEMTADS Adjunct Sensor Systems Hand-held EMI Sensor for Cued UXO...NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 2 . REPORT TYPE1. REPORT DATE (DD-MM-YYYY) 4

  4. TEMTADS Adjunct Sensor Systems Hand-held EMI Sensor for Cued UXO Discrimination (ESTCP MR-200807) and Man-Portable EMI Array for UXO Detection and Discrimination (ESTCP MR-200909) Cost and Performance Report

    DTIC Science & Technology

    2012-06-27

    notes and team orienteering functions. Data collection with the MP system at the former Camp Beale, CA is shown in Figure 5- 2 (right). 5.3.3...Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/ 6110 --12-9424 TEMTADS Adjunct Sensor Systems Hand-held EMI Sensor for Cued UXO...CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 2 . REPORT TYPE1. REPORT DATE (DD

  5. The Healthy Heart Race: A Short-Duration, Hands-on Activity in Cardiovascular Physiology for Museums and Science Festivals

    ERIC Educational Resources Information Center

    Pressley, Thomas A.; Limson, Melvin; Byse, Miranda; Matyas, Marsha Lakes

    2011-01-01

    The "Healthy Heart Race" activity provides a hands-on demonstration of cardiovascular function suitable for lay audiences. It was field tested during the United States of America Science and Engineering Festival held in Washington, DC, in October 2010. The basic equipment for the activity consisted of lengths of plastic tubing, a hand…

  6. Bolt installation tool for tightening large nuts and bolts

    NASA Technical Reports Server (NTRS)

    Mcdougal, A. R.; Norman, R. M.

    1974-01-01

    Large bolts and nuts are accurately tightened to structures without damaging torque stresses. There are two models of bolt installation tool. One is rigidly mounted and one is hand held. Each model includes torque-multiplier unit.

  7. Hand Held Device for Wireless Powering and Interrogation of Biomems Sensors and Actuators

    NASA Technical Reports Server (NTRS)

    Simons, Rainee N (Inventor); Miranda, Felix Antonio (Inventor)

    2007-01-01

    A compact, hand-held device for wireless powering, interrogation and data retrieval from at least one implanted sensor. The hand-held device includes an antenna for powering an implanted sensor and for receiving data from the implanted sensor to the hand-held device for at least one of storage, display or analysis. The hand-held device establishes electromagnetic coupling with a low radiating radio frequency power inductor in the implanted sensor at a predefined separation and the antenna geometry allows for the antenna to power, interrogate and retrieve data from the implanted sensor without strapping the hand-held device to a human body housing the implanted sensor The hand-held device optionally allows for activation of the implanted sensor only during interrogation and data retrieval.

  8. Driver Cellphone and Texting Bans in the United States: Evidence of Effectiveness

    PubMed Central

    McCartt, Anne T.; Kidd, David G.; Teoh, Eric R.

    2014-01-01

    Almost all U.S. states have laws limiting drivers’ cellphone use. The evidence suggests that all-driver bans on hand-held phone conversations have resulted in long-term reductions in hand-held phone use, and drivers in ban states reported higher rates of hands-free phone use and lower overall phone use compared with drivers in non-ban states. Bans on all phone use by teenage drivers have not been shown to reduce their phone use. The effects of texting bans on the rates of drivers’ texting are unknown. With regard to the effects of bans on crashes, 11 peer-reviewed papers or technical reports of all-driver hand-held phone bans and texting bans were reviewed. Some were single-state studies examining crash measures before and after a state ban; other national or multi-state studies compared crashes in states with and without bans over time. The results varied widely. The lack of appropriate controls and other challenges in conducting strong evaluations limited the findings of some studies. Thus, despite the proliferation of laws limiting drivers’ cellphone use, it is unclear whether they are having the desired effects on safety. Priorities for future research are suggested. PMID:24776230

  9. A Research and Development Strategy for Unexploded Ordnance Sensing

    DTIC Science & Technology

    1996-04-01

    Each lane was carefully traversed with the MK-26 Ordnance Detector (dual fluxgate magnetometer hand-held unit) and the operator hand-excavated any...proton-precessing magnetometers , optically pumped magnetometers , fluxgates magnetometers , and magnetometers based on superconducting quantum...sensitivity better than 0.05 nT, and the optically-pumped magnetometers have sensitivity better than 0.005 nT. Fluxgate magnetometers are based on solid

  10. 47 CFR 90.421 - Operation of mobile station units not under the control of the licensee.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... medical services activities. (3) On the Interoperability Channels in the 700 MHz Public Safety Band (See... in the 700 MHz Public Safety Band or by any licensee holding a license for any other public safety... hand-held and vehicular transmitters in the 700 MHz Band. (b) Industrial/Business Pool. Mobile units...

  11. 30 CFR 57.7053 - Moving hand-held drills.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Moving hand-held drills. 57.7053 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface and Underground § 57.7053 Moving hand-held drills. Before hand-held...

  12. 30 CFR 57.7053 - Moving hand-held drills.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Moving hand-held drills. 57.7053 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface and Underground § 57.7053 Moving hand-held drills. Before hand-held...

  13. 30 CFR 57.7053 - Moving hand-held drills.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Moving hand-held drills. 57.7053 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface and Underground § 57.7053 Moving hand-held drills. Before hand-held...

  14. 30 CFR 57.7053 - Moving hand-held drills.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Moving hand-held drills. 57.7053 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface and Underground § 57.7053 Moving hand-held drills. Before hand-held...

  15. 30 CFR 57.7053 - Moving hand-held drills.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Moving hand-held drills. 57.7053 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface and Underground § 57.7053 Moving hand-held drills. Before hand-held...

  16. 30 CFR 57.12033 - Hand-held electric tools.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...

  17. 30 CFR 57.12033 - Hand-held electric tools.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...

  18. 30 CFR 57.12033 - Hand-held electric tools.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...

  19. 30 CFR 57.12033 - Hand-held electric tools.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...

  20. 30 CFR 57.12033 - Hand-held electric tools.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...

  1. 30 CFR 56.7053 - Moving hand-held drills.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Moving hand-held drills. 56.7053 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7053 Moving hand-held drills. Before hand-held drills are moved from one...

  2. 30 CFR 56.7053 - Moving hand-held drills.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Moving hand-held drills. 56.7053 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7053 Moving hand-held drills. Before hand-held drills are moved from one...

  3. 30 CFR 56.7053 - Moving hand-held drills.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Moving hand-held drills. 56.7053 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7053 Moving hand-held drills. Before hand-held drills are moved from one...

  4. 30 CFR 56.7053 - Moving hand-held drills.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Moving hand-held drills. 56.7053 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7053 Moving hand-held drills. Before hand-held drills are moved from one...

  5. 30 CFR 56.7053 - Moving hand-held drills.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Moving hand-held drills. 56.7053 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7053 Moving hand-held drills. Before hand-held drills are moved from one...

  6. Technology Description Sheets form the AMC 1990 Technology Expo Held in Aberdeen Proving Ground, Maryland on 1-4 October 1990

    DTIC Science & Technology

    1990-10-04

    emission signals) " Compactness (can be hand-held). The ISOPADS was demonstrated to troop units at the Army Training Command, Grafenwoehr , West...To be controlled, the microwave chips and modules must be interconnected with remotely located components and subsystems. Utilizing metallic cables...forward observer systcm being developed for use in situations too dangerous for soldiers. such as nuclear- contaminated areas or in support of a minefield

  7. Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

    PubMed

    Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito

    2017-11-01

    [Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.

  8. Practical applications of hand-held computers in dermatology.

    PubMed

    Goldblum, Orin M

    2002-09-01

    For physicians, hand-held computers are gaining popularity as point of care reference tools. The convergence of hand-held computers, the Internet, and wireless networks will enable these devices to assume more essential roles as mobile transmitters and receivers of digital medical Information. In addition to serving as portable medical reference sources, these devices can be Internet-enabled, allowing them to communicate over wireless wide and local area networks. With enhanced wireless connectivity, hand-held computers can be used at the point of patient care for charge capture, electronic prescribing, laboratory test ordering, laboratory result retrieval, web access, e-mail communication, and other clinical and administrative tasks. Physicians In virtually every medical specialty have begun using these devices in various ways. This review of hand-held computer use in dermatology illustrates practical examples of the many different ways hand-held computers can be effectively used by the practicing dermatologist.

  9. Excimer laser therapy and narrowband ultraviolet B therapy for exfoliative cheilitis.

    PubMed

    Bhatia, Bhavnit K; Bahr, Brooks A; Murase, Jenny E

    2015-06-01

    Exfoliative cheilitis is a condition of unknown etiology characterized by hyperkeratosis and scaling of vermilion epithelium with cyclic desquamation. It remains largely refractory to treatment, including corticosteroid therapy, antibiotics, antifungals, and immunosuppressants. We sought to evaluate the safety and efficacy of excimer laser therapy and narrowband ultraviolet B therapy in female patients with refractory exfoliative cheilitis. We reviewed the medical records of two female patients who had been treated unsuccessfully for exfoliative cheilitis. We implemented excimer laser therapy, followed by hand-held narrowband UVB treatments for maintenance therapy, and followed them for clinical improvement and adverse effects. Both patients experienced significant clinical improvement with minimal adverse effects with excimer laser therapy 600-700 mJ/cm 2 twice weekly for several months. The most common adverse effects were bleeding and burning, which occurred at higher doses. The hand-held narrowband UVB unit was also an effective maintenance tool. Limitations include small sample size and lack of standardization of starting dose and dose increments. Excimer laser therapy is a well-tolerated and effective treatment for refractory exfoliative cheilitis with twice weekly laser treatments of up to 700 mJ/cm 2 . Transitioning to the hand-held narrowband UVB device was also an effective maintenance strategy.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hannum, David W.; Shannon, Gary W.

    This report describes the collaboration between the South Texas Specialized Crimes and Narcotics Task Force (STSCNTF) and Sandia National Laboratories (SNL) in a field test that provided prototype hand-held trace detection technology for use in counter-drug operations. The National Institute of Justice (NIJ)/National Law Enforcement and Corrections Technology Center (NLECTC)/Border Research and Technology Center (BRTC) was contacted by STSCNTF for assistance in obtaining cutting-edge technology. The BRTC created a pilot project for Sandia National Laboratories (SNL) and the STSCNTF for the use of SNL’s Hound, a hand-held sample collection and preconcentration system that, when combined with a commercial chemical detector,more » can be used for the trace detection of illicit drugs and explosives. The STSCNTF operates in an area of high narcotics trafficking where methods of concealment make the detection of narcotics challenging. Sandia National Laboratories’ (SNL) Contraband Detection Department personnel provided the Hound system hardware and operational training. The Hound system combines the GE VaporTracer2, a hand-held commercial chemical detector, with an SNL-developed sample collection and preconcentration system. The South Texas Task force reported a variety of successes, including identification of a major shipment of methamphetamines, the discovery of hidden compartments in vehicles that contained illegal drugs and currency used in drug deals, and the identification of a suspect in a nightclub shooting. The main advantage of the hand-held trace detection unit is its ability to quickly identify the type of chemical (drugs or explosives) without a long lag time for laboratory analysis, which is the most common analysis method for current law enforcement procedures.« less

  11. The Future of Fractions

    ERIC Educational Resources Information Center

    Usiskin, Zalman P.

    2007-01-01

    In the 1970s, the movement to the metric system (which has still not completely occurred in the United States) and the advent of hand-held calculators led some to speculate that decimal representation of numbers would render fractions obsolete. This provocative proposition stimulated Zalman Usiskin to write "The Future of Fractions" in 1979. He…

  12. Astronaut David Scott practicing for Gemini 8 EVA

    NASA Image and Video Library

    1966-02-01

    S66-19284 (1 Feb. 1966) --- Astronaut David R. Scott practicing for Gemini-8 extravehicular activity (EVA) in building 4 of the Manned Spacecraft Center on the air bearing floor. He is wearing the Hand-Held Maneuvering Unit which he will use during the EVA. Photo credit: NASA

  13. What is the best method to evaluate urine pH? A trial of three urinary pH measurement methods in a stone clinic.

    PubMed

    Ilyas, Rebecca; Chow, Karyee; Young, J Graham

    2015-01-01

    Monitoring of urinary pH is an important part of the assessment of patients with urinary tract stones. It provides valuable information about the future stone risk of certain patients and further allows the effective tailoring of medical intervention. Accurate measurement is therefore essential in these patients. The purpose of this study was to determine the most accurate method of measuring urinary pH in an outpatient setting. Materials, Methods, and Participants: Urine samples were collected from 200 patients attending stone clinics at The University Hospital of South Manchester. pH was measured by three commonly used methods: Siemens Clinitek Status pH meter, a hand-held pH meter, and litmus paper read visually. Results were compared with readings simultaneously obtained from a bench-top laboratory pH machine, which is the reference method for pH measurement. The pH readings obtained were analyzed using the Bland-Altman plot. When compared with the reference method, the hand-held pH meter differed the least with a mean bias of 0.0073 and a maximum under-read of -0.2 pH units and maximum over-read of +0.2 pH units. The Siemens Clinitek pH meter differed most with a mean bias of -0.108, with a maximum over-read of +0.99 pH units and a maximum under-read of 0.78 pH units. The pH values obtained with the litmus paper gave similar results to that of the Clinitek pH meter with a mean bias of -0.069, with a maximum over-read of 0.96 and maximum under-read of 0.82 pH units. The hand-held pH device gave urinary pH readings that most closely and consistently matched those of the reference bench-top laboratory machine. This method of pH measurement should be considered in stone clinics in patients with pH-dependent stone risk.

  14. Evaluation of U.S. Commercial-Off-the-Shelf Hand-Held Assays to Detect Opiate Pain Reliever Compounds in Multiple Biofluids

    DTIC Science & Technology

    2016-09-01

    EVALUATION OF U.S. COMMERCIAL-OFF-THE-SHELF HAND-HELD ASSAYS TO DETECT OPIATE PAIN RELIEVER COMPOUNDS IN...Commercial-Off-the-Shelf Hand-Held Assays to Detect Opiate Pain Reliever Compounds in Multiple Biofluids 5a. CONTRACT NUMBER 5b. GRANT NUMBER R...study, we evaluated the potential for several U.S. commercial-off-the-shelf (COTS) hand-held assays (HHAs) to detect members of the opiate pain reliever

  15. 46 CFR 160.036-5 - Marking.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-5 Marking. (a) General. Each hand-held rocket-propelled parachute red flare distress signal shall be legibly marked or labeled as follows: (Company brand or style designation) Hand-Held Rocket...

  16. 46 CFR 160.036-5 - Marking.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-5 Marking. (a) General. Each hand-held rocket-propelled parachute red flare distress signal shall be legibly marked or labeled as follows: (Company brand or style designation) Hand-Held Rocket...

  17. 46 CFR 160.036-5 - Marking.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-5 Marking. (a) General. Each hand-held rocket-propelled parachute red flare distress signal shall be legibly marked or labeled as follows: (Company brand or style designation) Hand-Held Rocket...

  18. 46 CFR 160.036-5 - Marking.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-5 Marking. (a) General. Each hand-held rocket-propelled parachute red flare distress signal shall be legibly marked or labeled as follows: (Company brand or style designation) Hand-Held Rocket...

  19. 46 CFR 160.036-5 - Marking.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-5 Marking. (a) General. Each hand-held rocket-propelled parachute red flare distress signal shall be legibly marked or labeled as follows: (Company brand or style designation) Hand-Held Rocket...

  20. Heavy-metal contamination on training ranges at the Grafenwoehr Training Area, Germany

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zellmer, S.D.; Schneider, J.F.

    1993-05-01

    Large quantities of lead and other heavy metals are deposited in the environment of weapons ranges during training exercises. This study was conducted to determine the type, degree, and extent of heavy-metal contamination on selected handgun, rifle, and hand-grenade ranges at Grafenwoehr Training Area, Germany. Soil, vegetation, and surface-water samples were collected and analyzed using the inductively-coupled plasma atomic-emission spectroscopy (ICP-AES) method and the toxic characterization leaching procedure (TCLP). The ICP-AES results show that above-normal levels of lead and copper are in the surface soil at the handgun range, high concentrations of lead and copper are in the berm andmore » soil surface at the rifle range, and elevated levels of cadmium and above-normal concentrations of arsenic, copper, and zinc are present in the surface soil at the hand-grenade range. The TCLP results show that surface soils can be considered hazardous waste because of lead content at the rifle range and because of cadmium concentration at the hand-grenade range. Vegetation at the handgun and rifle ranges has above-normal concentrations of lead. At the hand-grenade range, both vegetation and surface water have high levels of cadmium. A hand-held X-ray fluorescence (XRF) spectrum analyzer was used to measure lead concentrations in soils in a field test of the method. Comparison of XRF readings with ICP-AES results for lead indicate that the accuracy and precision of the hand-held XRF unit must improve before the unit can be used as more than a screening tool. Results of this study show that heavy-metal contamination at all three ranges is limited to the surface soil; heavy metals are not being leached into the soil profile or transported into adjacent areas.« less

  1. 30 CFR 56.14116 - Hand-held power tools.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...

  2. 30 CFR 56.14116 - Hand-held power tools.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...

  3. 30 CFR 56.14116 - Hand-held power tools.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...

  4. 30 CFR 57.14116 - Hand-held power tools.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...

  5. 30 CFR 56.14116 - Hand-held power tools.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...

  6. 30 CFR 57.14116 - Hand-held power tools.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...

  7. 30 CFR 57.14116 - Hand-held power tools.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...

  8. 30 CFR 56.14116 - Hand-held power tools.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...

  9. 30 CFR 57.14116 - Hand-held power tools.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...

  10. 30 CFR 57.14116 - Hand-held power tools.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...

  11. The Data Egg: A new solution to text entry barriers

    NASA Technical Reports Server (NTRS)

    Friedman, Gary L.

    1993-01-01

    A unit that allows text entry with only one hand has been developed, and holds the promise of allowing computers to be truly portable. It is unique in that it allows operation in any position, freeing the user from the traditional constraints of having to be seated near a desk. This hand held, chord-key-based unit can be used either autonomously for idea capturing, or tethered to a personal computer and used as an auxiliary keyboard. Astronauts, journalists, the bedridden, and anyone else normally barred from using a computer while on the job could also benefit from this form of man-machine interface, which has been dubbed the 'Data Egg'.

  12. Trace Contraband Detection Field-Test by the South Texas Specialized Crimes and Narcotics Task Force

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hannum, David W.; Shannon, Gary W.

    This report describes the collaboration between the South Texas Specialized Crimes and Narcotics Task Force (STSCNTF) and Sandia National Laboratories (SNL) in a field test that provided prototype hand-held trace detection technology for use in counter-drug operations. The National Institute of Justice (NIJ)/National Law Enforcement and Corrections Technology Center (NLECTC)/Border Research and Technology Center (BRTC) was contacted by STSCNTF for assistance in obtaining cutting-edge technology. The BRTC created a pilot project for Sandia National Laboratories (SNL) and the STSCNTF for the use of SNL’s Hound, a hand-held sample collection and preconcentration system that, when combined with a commercial chemical detector,more » can be used for the trace detection of illicit drugs and explosives. The STSCNTF operates in an area of high narcotics trafficking where methods of concealment make the detection of narcotics challenging. Sandia National Laboratories’ (SNL) Contraband Detection Department personnel provided the Hound system hardware and operational training. The Hound system combines the GE VaporTracer2, a hand-held commercial chemical detector, with an SNL-developed sample collection and preconcentration system. The South Texas Task force reported a variety of successes, including identification of a major shipment of methamphetamines, the discovery of hidden compartments in vehicles that contained illegal drugs and currency used in drug deals, and the identification of a suspect in a nightclub shooting. The main advantage of the hand-held trace detection unit is its ability to quickly identify the type of chemical (drugs or explosives) without a long lag time for laboratory analysis, which is the most common analysis method for current law enforcement procedures.« less

  13. Hand-held radiometry: A set of notes developed for use at the Workshop of Hand-held radiometry

    NASA Technical Reports Server (NTRS)

    Jackson, R. D.; Pinter, P. J., Jr.; Reginato, R. J.; Idso, S. B. (Principal Investigator)

    1980-01-01

    A set of notes was developed to aid the beginner in hand-held radiometry. The electromagnetic spectrum is reviewed, and pertinent terms are defined. View areas of multiband radiometers are developed to show the areas of coincidence of adjacent bands. The amounts of plant cover seen by radiometers having different fields of view are described. Vegetation indices are derived and discussed. Response functions of several radiometers are shown and applied to spectrometer data taken over 12 wheat plots, to provide a comparison of instruments and bands within and among instruments. The calculation of solar time is reviewed and applied to the calculation of the local time of LANDSAT satellite overpasses for any particular location in the Northern Hemisphere. The use and misuse of hand-held infrared thermometers are discussed, and a procedure for photographic determination of plant cover is described. Some suggestions are offered concerning procedures to be followed when collecting hand-held spectral and thermal data. A list of references pertinent to hand-held radiometry is included.

  14. CGBA, Pilot Kent Rominger films HHDTC units in Spacelab

    NASA Image and Video Library

    1995-11-05

    STS073-131-014 (20 October-5 November 1995) --- Astronaut Kent V. Rominger, STS-73 pilot, uses a camcorder to record progress in the Hand-Held Diffusion Test Cell (HHDTC) experiment. This test dealt with crystal growth by liquid-to-liquid diffusion. Four HHDTC units containing four test cells each produced protein crystals by diffusing one liquid to another. Rominger joined four other NASA astronauts and two guest researchers for 16 days of in-space United States Microgravity Laboratory 2 (USML-2) research aboard the Space Shuttle Columbia.

  15. Choosing a Hand-Held Inventory Device

    ERIC Educational Resources Information Center

    Green, Lois; Hughes, Janet; Neff, Verne; Notartomas, Trish

    2008-01-01

    In spring of 2006, a task force was charged to look at the feasibility of acquiring hand-held inventory devices for the Pennsylvania State University Libraries (PSUL). The task force's charge was not to look at the whole concept of doing an inventory, but rather to focus on the feasibility of acquiring hand-held devices to use in an inventory.…

  16. Implications of Hand Held Electronic Games and Microcomputers for Informal Learning.

    ERIC Educational Resources Information Center

    Kee, Daniel W.

    The use of hand-held electronic devices and microcomputers in places of public access and in the home are discussed. First, the different activities supported by this technology are described, with emphasis on the commonality of game playing to both hand-held devices and microcomputers. The need for research to investigate the motivational…

  17. 78 FR 27441 - NIJ Evaluation of Hand-Held Cell Phone Detector Devices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-10

    ... Hand-Held Cell Phone Detector Devices AGENCY: National Institute of Justice, Department of Justice...-held cell phone detector devices for participation in an evaluation by the NIJ Corrections Technology...-held cell phone detector devices for participation in an evaluation by the NIJ Corrections Technology...

  18. STS-9 and Amateur Radio. NASA Educational Briefs for the Classroom.

    ERIC Educational Resources Information Center

    National Aeronautics and Space Administration, Washington, DC.

    Designed for secondary and postsecondary school students, the article discusses the STS-9 (Space Transportation System), a hand-held amateur radio (ham) station used on the Space Shuttle Columbia. The article details the mechanics of this battery-powered unit and how it is used. Separate sections discuss necessary equipment for picking up space…

  19. Urban field guide: applying social forestry observation techniques to the east coast megalopolis

    Treesearch

    E. Svendsen; V. Marshall; M.F. Ufer

    2006-01-01

    A changing economy and different lifestyles have altered the meaning of the forest in the northeastern United States, prompting scientists to reconsider the spatial form, stewardship and function of the urban forest. The Authors describe how social observation techniques and the employment of a novel, locally based, participatory hand-held monitoring system could aid...

  20. The use of an intraoral electrolarynx for an edentulous patient: a clinical report.

    PubMed

    Wee, Alvin G; Wee, Lisa A; Cheng, Ansgar C; Cwynar, Roger B

    2004-06-01

    This clinical report describes the clinical requirements, treatment sequence, and use of a relatively new intraoral electrolarynx for a completely edentulous patient. This device consists of a sound source attached to the maxilla and a hand-held controller unit that controls the pitch and volume of the intraoral sound source via transmitted radio waves.

  1. Simple Multiplexing Hand-Held Control Unit

    NASA Technical Reports Server (NTRS)

    Hannaford, Blake

    1989-01-01

    Multiplexer consists of series of resistors, each shunted by single-pole, single-throw switch. User operates switches by pressing buttons or squeezing triggers. Prototype includes three switches operated successfully in over 200 hours of system operations. Number of switches accommodated determined by signal-to-noise ratio of current source, noise induced in control unit and cable, and number of bits in output of analog-to-digital converter. Because many computer-contolled robots have extra analog-to-digital channels, such multiplexer added at little extra cost.

  2. Hand-held Raman sensor head for in-situ characterization of meat quality applying a microsystem 671 nm diode laser

    NASA Astrophysics Data System (ADS)

    Schmidt, Heinar; Sowoidnich, Kay; Maiwald, Martin; Sumpf, Bernd; Kronfeldt, Heinz-Detlef

    2009-05-01

    A hand-held Raman sensor head was developed for the in-situ characterization of meat quality. As light source, a microsystem based external cavity diode laser module (ECDL) emitting at 671 nm was integrated in the sensor head and attached to a miniaturized optical bench which contains lens optics for excitation and signal collection as well as a Raman filter stage for Rayleigh rejection. The signal is transported with an optical fiber to the detection unit which was in the initial phase a laboratory spectrometer with CCD detector. All elements of the ECDL are aligned on a micro optical bench with 13 x 4 mm2 footprint. The wavelength stability is provided by a reflection Bragg grating and the laser has an optical power of up to 200 mW. However, for the Raman measurements of meat only 35 mW are needed to obtain Raman spectra within 1 - 5 seconds. Short measuring times are essential for the hand-held device. The laser and the sensor head are characterized in terms of stability and performance for in-situ Raman investigations. The function is demonstrated in a series of measurements with raw and packaged pork meat as samples. The suitability of the Raman sensor head for the quality control of meat and other products will be discussed.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ivanov, Oleg P.; Semin, Ilya A.; Potapov, Victor N.

    Gamma-ray imaging is the most important way to identify unknown gamma-ray emitting objects in decommissioning, security, overcoming accidents. Over the past two decades a system for producing of gamma images in these conditions became more or less portable devices. But in recent years these systems have become the hand-held devices. This is very important, especially in emergency situations, and measurements for safety reasons. We describe the first integrated hand-held instrument for emergency and security applications. The device is based on the coded aperture image formation, position sensitive gamma-ray (X-ray) detector Medipix2 (detectors produces by X-ray Imaging Europe) and tablet computer.more » The development was aimed at creating a very low weight system with high angular resolution. We present some sample gamma-ray images by camera. Main estimated parameters of the system are the following. The field of view video channel ∼ 490 deg. The field of view gamma channel ∼ 300 deg. The sensitivity of the system with a hexagonal mask for the source of Cs-137 (Eg = 662 keV), is in units of dose D ∼ 100 mR. This option is less then order of magnitude worse than for the heavy, non-hand-held systems (e.g., gamma-camera Cartogam, by Canberra.) The angular resolution of the gamma channel for the sources of Cs-137 (Eg = 662 keV) is about 1.20 deg. (authors)« less

  4. KSC-2010-4886

    NASA Image and Video Library

    2010-09-28

    CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, Roger Elliot with United Space Alliance addresses the attendees at a ceremony being held to commemorate the move from Kennedy's Assembly Refurbishment Facility (ARF) to the Vehicle Assembly Building (VAB) of the Space Shuttle Program's final solid rocket booster structural assembly -- the right-hand forward. The move was postponed because of inclement weather. Photo credit: NASA/Kim Shiflett

  5. Defect Depth Measurement Using White Light Interferometry

    NASA Technical Reports Server (NTRS)

    Parker, Don; Starr, Stan

    2009-01-01

    The objectives of the White Light Interferometry project are the following: (1) Demonstrate a small hand-held instrument capable of performing inspections of identified defects on Orbiter outer pane window surfaces. (2) Build and field-test a prototype device using miniaturized optical components. (3) Modify the instrument based on field testing and begin the conversion of the unit to become a certified shop-aid.

  6. Driver hand-held cellular phone use: a four-year analysis.

    PubMed

    Eby, David W; Vivoda, Jonathon M; St Louis, Renée M

    2006-01-01

    The use of hand-held cellular (mobile) phones while driving has stirred more debate, passion, and research than perhaps any other traffic safety issue in the past several years. There is ample research showing that the use of either hand-held or hands-free cellular phones can lead to unsafe driving patterns. Whether or not these performance deficits increase the risk of crash is difficult to establish, but recent studies are beginning to suggest that cellular phone use elevates crash risk. The purpose of this study was to assess changes in the rate of hand-held cellular phone use by motor-vehicle drivers on a statewide level in Michigan. This study presents the results of 13 statewide surveys of cellular phone use over a 4-year period. Hand-held cellular phone use data were collected through direct observation while vehicles were stopped at intersections and freeway exit ramps. Data were weighted to be representative of all drivers traveling during daylight hours in Michigan. The study found that driver hand-held cellular phone use has more than doubled between 2001 and 2005, from 2.7% to 5.8%. This change represents an average increase of 0.78 percentage points per year. The 5.8% use rate observed in 2005 means that at any given daylight hour, around 36,550 drivers were conversing on cellular phones while driving on Michigan roadways. The trend line fitted to these data predicts that by the year 2010, driver hand-held cellular phone use will be around 8.6%, or 55,000 drivers at any given daylight hour. These results make it clear that cellular phone use while driving will continue to be an important traffic safety issue, and highlight the importance of continued attempts to generate new ways of alleviating this potential hazard.

  7. Spring wheat-leaf phytomass and yield estimates from airborne scanner and hand-held radiometer measurements

    NASA Technical Reports Server (NTRS)

    Aase, J. K.; Siddoway, F. H.; Millard, J. P.

    1984-01-01

    An attempt has been made to relate hand-held radiometer measurements, and airborne multispectral scanner readings, with both different wheat stand densities and grain yield. Aircraft overflights were conducted during the tillering, stem extension and heading period stages of growth, while hand-held radiometer readings were taken throughout the growing season. The near-IR/red ratio was used in the analysis, which indicated that both the aircraft and the ground measurements made possible a differentiation and evaluation of wheat stand densities at an early enough growth stage to serve as the basis of management decisions. The aircraft data also corroborated the hand-held radiometer measurements with respect to yield prediction. Winterkill was readily evaluated.

  8. Computer implemented method, and apparatus for controlling a hand-held tool

    NASA Technical Reports Server (NTRS)

    Wagner, Kenneth William (Inventor); Taylor, James Clayton (Inventor)

    1999-01-01

    The invention described here in is a computer-implemented method and apparatus for controlling a hand-held tool. In particular, the control of a hand held tool is for the purpose of controlling the speed of a fastener interface mechanism and the torque applied to fasteners by the fastener interface mechanism of the hand-held tool and monitoring the operating parameters of the tool. The control is embodied in intool software embedded on a processor within the tool which also communicates with remote software. An operator can run the tool, or through the interaction of both software, operate the tool from a remote location, analyze data from a performance history recorded by the tool, and select various torque and speed parameters for each fastener.

  9. KSC-2010-4889

    NASA Image and Video Library

    2010-09-28

    CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, United Space Alliance employees gather and hold up a banner at a ceremony being held to commemorate the move from Kennedy's Assembly Refurbishment Facility (ARF) to the Vehicle Assembly Building (VAB) of the Space Shuttle Program's final solid rocket booster structural assembly -- the right-hand forward. The move was postponed because of inclement weather. Photo credit: NASA/Kim Shiflett

  10. Surgical guidance system using hand-held probe with accompanying positron coincidence detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majewski, Stanislaw; Weisenberger, Andrew G.

    A surgical guidance system offering different levels of imaging capability while maintaining the same hand-held convenient small size of light-weight intra-operative probes. The surgical guidance system includes a second detector, typically an imager, located behind the area of surgical interest to form a coincidence guidance system with the hand-held probe. This approach is focused on the detection of positron emitting biomarkers with gamma rays accompanying positron emissions from the radiolabeled nuclei.

  11. Automated Hand-Held UXO Detection, Classification & Discrimination Sensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bell, Thomas H.

    2000-06-12

    The research focused on procedures for target discrimination and classification using hand-held EMI sensors. The idea is to have a small, portable sensor that can be operated in a sweep or similar pattern in front of the operator, and that is capable of distinguishing between buried UXO and clutter on the spot. Curing Phase 1, we developed the processing techniques for distinguishing between buried UXO and clutter using the EM61-HH hand-held metal detector.

  12. A Novel Hand-Held Optical Imager with Real-Time Coregistration Facilities Toward Diagnostic Mammography

    DTIC Science & Technology

    2011-01-01

    Journal Publications (1) S.J. Erickson, S.L. Martinez, J. Gonzalez, L. Caldera , and A. Godavarty. “Improved detection limits using a hand-held...Erickson, S. Martinez, J. Gonzalez, L. Caldera , and A. Godavarty. “Non- invasive Diagnostic Breast Imaging using a Hand-held Optical Imager...Proceedings of the 14th World Multi-Conference on Systems, Cybernetics and Informatics, 2010. (4) S.J. Erickson, S. Martinez, L. Caldera , and A

  13. Validation of a portable nitric oxide analyzer for screening in primary ciliary dyskinesias.

    PubMed

    Harris, Amanda; Bhullar, Esther; Gove, Kerry; Joslin, Rhiannon; Pelling, Jennifer; Evans, Hazel J; Walker, Woolf T; Lucas, Jane S

    2014-02-10

    Nasal nitric oxide (nNO) levels are very low in primary ciliary dyskinesia (PCD) and it is used as a screening test. We assessed the reliability and usability of a hand-held analyser in comparison to a stationary nitric oxide (NO) analyser in 50 participants (15 healthy, 13 PCD, 22 other respiratory diseases; age 6-79 years). Nasal NO was measured using a stationary NO analyser during a breath-holding maneuver, and using a hand-held analyser during tidal breathing, sampling at 2 ml/sec or 5 ml/sec. The three methods were compared for their specificity and sensitivity as a screen for PCD, their success rate in different age groups, within subject repeatability and acceptability. Correlation between methods was assessed. Valid nNO measurements were obtained in 94% of participants using the stationary analyser, 96% using the hand-held analyser at 5 ml/sec and 76% at 2 ml/sec. The hand-held device at 5 ml/sec had excellent sensitivity and specificity as a screening test for PCD during tidal breathing (cut-off of 30 nL/min,100% sensitivity, >95% specificity). The cut-off using the stationary analyser during breath-hold was 38 nL/min (100% sensitivity, 95% specificity). The stationary and hand-held analyser (5 ml/sec) showed reasonable within-subject repeatability(% coefficient of variation = 15). The hand-held NO analyser provides a promising screening tool for PCD.

  14. Rapid and automatic chemical identification of the medicinal flower buds of Lonicera plants by the benchtop and hand-held Fourier transform infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Chen, Jianbo; Guo, Baolin; Yan, Rui; Sun, Suqin; Zhou, Qun

    2017-07-01

    With the utilization of the hand-held equipment, Fourier transform infrared (FT-IR) spectroscopy is a promising analytical technique to minimize the time cost for the chemical identification of herbal materials. This research examines the feasibility of the hand-held FT-IR spectrometer for the on-site testing of herbal materials, using Lonicerae Japonicae Flos (LJF) and Lonicerae Flos (LF) as examples. Correlation-based linear discriminant models for LJF and LF are established based on the benchtop and hand-held FT-IR instruments. The benchtop FT-IR models can exactly recognize all articles of LJF and LF. Although a few LF articles are misjudged at the sub-class level, the hand-held FT-IR models are able to exactly discriminate LJF and LF. As a direct and label-free analytical technique, FT-IR spectroscopy has great potential in the rapid and automatic chemical identification of herbal materials either in laboratories or in fields. This is helpful to prevent the spread and use of adulterated herbal materials in time.

  15. Deadly distractions.

    PubMed

    Zuzek, Crystal

    2013-04-01

    In 2011, the National Transportation Safety Board urged all states to ban the use of portable electronic devices while driving, including hand-held and hands-free devices. Texting while driving concerns several Texas legislators, who have filed bills, backed by the Texas Medical Association, to ban the practice. TMA physicians recognize that the use of hand-held and hands-free devices and other factors associated with distracted driving affect their patients' safety.

  16. Detecting Plant Stress

    NASA Technical Reports Server (NTRS)

    2001-01-01

    Through an exclusive patent license from NASA Stennis Space Center, Spectrum Technologies, Inc., has developed a hand-held tool that helps farmers, foresters and other growers detect unhealthy crops before the human eye can see the damage. Developed by two NASA researchers, the Observer,TM shows the viewer which plants are under stress through multispectral imaging, a process that uses specific wavelengths of the light spectrum to obtain information about objects-in this case, plants. With this device, several wavelengths of light collect information about the plant and results are immediately processed and displayed. NASA research found that previsible signs of stress, such as such as a lack of nutrients, insufficient water, disease, or insect damage, can be detected by measuring the chlorophyll content based on light energy reflected from the plant. The Observer detects stress up to 16 days before deterioration is visible to the eye. Early detection provides an opportunity to reverse stress and save the plant. The hand-held, easily operated unit works in both natural and artificial light, making it suitable for outdoor or indoor planting.

  17. 77 FR 1768 - Self-Regulatory Organizations; New York Stock Exchange LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-11

    ... Held Device--Opening and Closing Order Imbalances Only (Together the ``Hand Held Device Fees''), the... the NYSE e-Broker[supreg] Hand Held Device--Opening and Closing Order Imbalances Only (together the... Imbalances Only, the $1,000 per year fee for approval of a pre-qualified substitute, and the $250 per year...

  18. Hand-Held Units for Short-Range Wireless Biotelemetry

    NASA Technical Reports Server (NTRS)

    Miranda, Felix A.; Simons, Rainee N.

    2008-01-01

    Special-purpose hand-held radiotransceiver units have been proposed as means of short-range radio powering and interrogation of surgically implanted microelectromechanical sensors and actuators. These units are based partly on the same principles as those of the units described in "Printed Multi- Turn Loop Antennas for RF Biotelemetry" (LEW-17879-1), NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 48. Like the previously reported units, these units would make it unnecessary to have wire connections between the implanted devices and the external equipment used to activate and interrogate them. Like a unit of the previously reported type, a unit of the type now proposed would include a printed-circuit antenna on a dielectric substrate. The antenna circuitry would include integrated surface-mount inductors for impedance tuning. Circuits for processing the signals transmitted and received by the antenna would be included on the substrate. During operation, the unit would be positioned near (but not in electrical contact with) a human subject, in proximity to a microelectromechanical sensor or actuator that has been surgically implanted in the subject. It has been demonstrated that significant electromagnetic coupling with an implanted device could be established at a distance of as much as 4 in. (.10 cm). During operation in the interrogation mode, the antenna of the unit would receive a radio telemetry signal transmitted by the surgically implanted device. The antenna substrate would have dimensions of approximately 3.25 by 3.75 inches (approximately 8.3 by 9.5 cm). The substrate would have a thickness of the order of 30 mils (of the order of a somewhat less than a millimeter). The substrate would be made of low-radiofrequency- loss dielectric material that could be, for example, fused quartz, alumina, or any of a number of commercially available radio-frequency dielectric composite materials. The antenna conductors would typically be made of copper or a combination of chromium and gold. The choice of metal and the thickness of the metal layer(s) would depend on the choice of substrate material. For example, on a quartz or alumina substrate, one would typically use a layer of chromium 150 A thick and a layer of gold 2 m thick. The proposed units and the implanted devices that they would interrogate or activate would be inherently safe to use. They would operate at low radiated-power levels for short interrogation times (typically, milliseconds). Hence, there would be little local heating of tissues surrounding the implanted devices and little absorption of radio energy by such sensitive body parts as the eyes and the brain. Because the implanted devices would not depend on battery power and would be activated only during short interrogation intervals and would otherwise be in the goff h state most of the time, the useful lifetimes of the implanted devices would be greater than those of comparable battery-powered implanted devices. The compactness of the hand-held transceiver units would facilitate transport and storage and would facilitate self-diagnosis by patients able to handle the units while away from medical facilities.

  19. Structural Orientations Adjacent to Some Colorado Geothermal Systems

    DOE Data Explorer

    Richard

    2012-02-01

    Structural orientations (fractures, joints, faults, lineaments, bedding orientations, etc.) were collected with a standard Brunton compass during routine field examinations of geothermal phenomena in Colorado. Often multiple orientations were taken from one outcrop. Care was taken to ensure outcrops were "in place". Point data was collected with a hand-held GPS unit. The structural data is presented both as standard quadrant measurements and in format suitable for ESRI symbology

  20. ONRASIA Scientific Information Bulletin. Volume 8, Number 3, July- September 1993

    DTIC Science & Technology

    1993-09-01

    the Ninth Symposium on Preconditioned Conjugate Dr. Steven F. Ashby Gradient Methods , which he organized. Computing Sciences Department Computing...ditioned Conjugate Gradient Methods , held at Keio chines and is currently a topic of considerable University (Yokohama). During this meeting, I interest...in the United States. In Japan, on the other discussed iterative methods for linear systems with hand, this technique does not appear to be too well

  1. Implementation Plan for Flexible Automation in U.S. Shipyards

    DTIC Science & Technology

    1985-01-01

    process steps, cramped work sites, interrupted geometries , irregular or novel shapes, and other factors that affect automatability. We also try to...held by 2 hands in awkward places. Interrupt geometry of plates and beams. Cannot predict outcome. Creates need to measure and recut. Automation, if...of standard. enough over time I every job. I Rearrange work.Redefine work units. Too many interruptions Time, space, geometry only a little work gets

  2. Borehole survey instrument

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharp, H.E.; Lin, J.W. III; Macha, E.S.

    1984-12-04

    A borehole survey instrument is provided having a meniscus type floating compass member with indicia thereon for indicating azimuth and inclination. A light source is disposed below the indicia for illuminating the indicia upward through the liquid through which the meniscus type floating compass member floats. A lens system is provided for focusing the image of the illuminated compass member upon a film disposed below the compass member. This arrangement permits the centering post for the compass member to be of minimum diameter consistent with rigidity requirements and permits a high angle compass member to indicate angles of inclination approachingmore » ninety degrees. A multiple light bulb light source is utilized and each light bulb is mounted in a manner which permits a single light bulb to illuminate the entire compass member. A hand-held programming and diagnostic unit is provided which may be momentarily electrically mated with the borehole survey tool to input a programmed timed delay and diagnostically test both the condition of the light bulbs utilized as the illumination source and the state of the batteries within the instrument. This hand-held programmable unit eliminates all the mechanical programming switches and permits the instrument to be completely sealed from the pressure, fluids and contaminants normally found in a well bore.« less

  3. Vibration and impulsivity analysis of hand held olive beaters.

    PubMed

    Deboli, Roberto; Calvo, Angela; Preti, Christian

    2016-07-01

    To provide more effective evaluations of hand arm vibration syndromes caused by hand held olive beaters, this study focused on two aspects: the acceleration measured at the tool pole and the analysis of the impulsivity, using the crest factor. The signals were frequency weighted using the weighting curve Wh as described in the ISO 5349-1 standard. The same source signals were also filtered by the Wh-bl filter (ISO/TS 15694), because the weighting filter Wh (unlike the Wh-bl filter) could underestimate the effect of high frequency vibration on vibration-induced finger disorders. Ten (experienced) male operators used three beater models (battery powered) in the real olive harvesting condition. High vibration total values were obtained with values never lower than 20 m(-2). Concerning the crest factor, the values ranged from 5 to more than 22. This work demonstrated that the hand held olive beaters produced high impulsive loads comparable to the industry hand held tools. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  4. Hand-held computer operating system program for collection of resident experience data.

    PubMed

    Malan, T K; Haffner, W H; Armstrong, A Y; Satin, A J

    2000-11-01

    To describe a system for recording resident experience involving hand-held computers with the Palm Operating System (3 Com, Inc., Santa Clara, CA). Hand-held personal computers (PCs) are popular, easy to use, inexpensive, portable, and can share data among other operating systems. Residents in our program carry individual hand-held database computers to record Residency Review Committee (RRC) reportable patient encounters. Each resident's data is transferred to a single central relational database compatible with Microsoft Access (Microsoft Corporation, Redmond, WA). Patient data entry and subsequent transfer to a central database is accomplished with commercially available software that requires minimal computer expertise to implement and maintain. The central database can then be used for statistical analysis or to create required RRC resident experience reports. As a result, the data collection and transfer process takes less time for residents and program director alike, than paper-based or central computer-based systems. The system of collecting resident encounter data using hand-held computers with the Palm Operating System is easy to use, relatively inexpensive, accurate, and secure. The user-friendly system provides prompt, complete, and accurate data, enhancing the education of residents while facilitating the job of the program director.

  5. Hand-held medical robots.

    PubMed

    Payne, Christopher J; Yang, Guang-Zhong

    2014-08-01

    Medical robots have evolved from autonomous systems to tele-operated platforms and mechanically-grounded, cooperatively-controlled robots. Whilst these approaches have seen both commercial and clinical success, uptake of these robots remains moderate because of their high cost, large physical footprint and long setup times. More recently, researchers have moved toward developing hand-held robots that are completely ungrounded and manipulated by surgeons in free space, in a similar manner to how conventional instruments are handled. These devices provide specific functions that assist the surgeon in accomplishing tasks that are otherwise challenging with manual manipulation. Hand-held robots have the advantages of being compact and easily integrated into the normal surgical workflow since there is typically little or no setup time. Hand-held devices can also have a significantly reduced cost to healthcare providers as they do not necessitate the complex, multi degree-of-freedom linkages that grounded robots require. However, the development of such devices is faced with many technical challenges, including miniaturization, cost and sterility, control stability, inertial and gravity compensation and robust instrument tracking. This review presents the emerging technical trends in hand-held medical robots and future development opportunities for promoting their wider clinical uptake.

  6. Utility of hand-held devices in diagnosis and triage of cardiovascular emergencies. Observations during implementation of a PACS-based system in an acute aortic syndrome (AAS) network.

    PubMed

    Matar, Ralph; Renapurkar, Rahul; Obuchowski, Nancy; Menon, Venu; Piraino, David; Schoenhagen, Paul

    2015-01-01

    Prompt diagnosis and early referral to specialized centers is critical for patients presenting with cardiovascular emergencies, including acute aortic syndromes (AAS). Prior data has suggested that mobile access to imaging studies with hand-held devices can accelerate diagnosis and management. We conducted a study to determine the diagnostic accuracy of a hand-held device compared to conventional dedicated work-stations for diagnosing a spectrum of cardiovascular emergencies, predominantly acute aortic pathology. This study included 104 cases who underwent computed tomography (CT)-scan during "on-call'' hours between January, 2013 and August, 2014 for suspected AAS. Assessment was performed on a hand-held device independently by two readers using an iPhone5 connected via secure connection to web-based PACS servers. The subsequent interpretation from a dedicated workstation coupled with the diagnosis at the time of discharge was used as the reference standard for determining the presence or absence of an acute abnormality. Sensitivity and Specificity were calculated on a per patient basis. Readers' sensitivity and specificity using the hand-held device to diagnose acute chest pathology were calculated. Hand-held device evaluation was determined to have a sensitivity of 85.2% and a specificity of 98.6% by reader A and a sensitivity of 96.3% and specificity of 100% by reader B. Of 103 cases interpreted by both readers, the readers agreed about the diagnosis in 98 cases (95.1%). This study demonstrates that hand-held devices can be a potential useful tool to assist in diagnosis and triage of patients presenting with cardiovascular emergencies. Further studies are needed to assess the impact of screen size and resolution. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  7. Fixture for winding transformers

    NASA Technical Reports Server (NTRS)

    Mclyman, M. T.

    1980-01-01

    Bench-mounted fixture assists operator in winding toroid-shaped transformer cores. Toroid is rigidly held in place as wires are looped around. Arrangement frees both hands for rapid winding and untangling of wires that occurs when core is hand held.

  8. Development of Hand-Held Thermographic Inspection Technologies

    DOT National Transportation Integrated Search

    2009-09-01

    This study explored the application of hand-held thermographic cameras for the detection of subsurface delaminations in concrete bridges. The goal of the research was to provide maintenance and inspection personnel with an effective tool for detectin...

  9. Development of hand-held thermographic inspection technologies.

    DOT National Transportation Integrated Search

    2009-09-01

    This study explored the application of hand-held thermographic cameras for the detection of subsurface delaminations in concrete : bridges. The goal of the research was to provide maintenance and inspection personnel with an effective tool for detect...

  10. Hand-held monitor of sympathetic nervous system using salivary amylase activity and its validation by driver fatigue assessment.

    PubMed

    Yamaguchi, Masaki; Deguchi, Mitsuo; Wakasugi, Junichi; Ono, Shin; Takai, Noriyasu; Higashi, Tomoyuki; Mizuno, Yasufumi

    2006-01-15

    In order to realize a hand-held monitor of the sympathetic nervous system, we fabricated a completely automated analytical system for salivary amylase activity using a dry-chemistry system. This was made possible by the fabrication of a disposable test-strip equipped with built-in collecting and reagent papers and an automatic saliva transfer device. In order to cancel out the effects of variations in environmental temperature and pH of saliva, temperature- and pH-adjusted equations were experimentally determined, and each theoretical value was input into the memory of the hand-held monitor. Within a range of salivary amylase activity between 10 and 140 kU/l, the calibration curve for the hand-held monitor showed a coefficient with R(2)=0.97. Accordingly, it was demonstrated that the hand-held monitor enabled a user to automatically measure the salivary amylase activity with high accuracy with only 30 microl sample of saliva within a minute from collection to completion of the measurement. In order to make individual variations of salivary amylase activity negligible during driver fatigue assessment, a normalized equation was proposed. The normalized salivary amylase activity correlated with the mental and physical fatigue states. Thus, this study demonstrated that an excellent hand-held monitor with an algorithm for normalization of individuals' differences in salivary amylase activity, which could be easily and quickly used for evaluating the activity of the sympathetic nervous system at any time. Furthermore, it is suggested that the salivary amylase activity might be used as a better index for psychological research.

  11. Driver electronic device use in 2013.

    DOT National Transportation Integrated Search

    2015-04-01

    The percentage of drivers text-messaging or visibly manipulating : hand-held devices increased from 1.5 percent in : 2012 to 1.7 percent in 2013; however, this was not a statistically : significant increase. Driver hand-held cell phone : use decrease...

  12. Hand-held radiometer red and photographic infrared spectral measurements of agricultural crops

    NASA Technical Reports Server (NTRS)

    Tucker, C. J.; Fan, C. J.; Elgin, J. H., Jr.; Mcmurtrey, J. E., III

    1978-01-01

    Red and photographic infrared radiance data, collected under a variety of conditions at weekly intervals throughout the growing season using a hand-held radiometer, were used to monitor crop growth and development. The vegetation index transformation was used to effectively compensate for the different irradiational conditions encountered during the study period. These data, plotted against time, compared the different crops measured by comparing their green leaf biomass dynamics. This approach, based entirely upon spectral inputs, closely monitors crop growth and development and indicates the promise of ground-based hand-held radiometer measurements of crops.

  13. Methods and instruments for materials testing

    NASA Technical Reports Server (NTRS)

    Hansma, Paul (Inventor); Drake, Barney (Inventor); Rehn, Douglas (Inventor); Adams, Jonathan (Inventor); Lulejian, Jason (Inventor)

    2011-01-01

    Methods and instruments for characterizing a material, such as the properties of bone in a living human subject, using a test probe constructed for insertion into the material and a reference probe aligned with the test probe in a housing. The housing is hand held or placed so that the reference probe contacts the surface of the material under pressure applied either by hand or by the weight of the housing. The test probe is inserted into the material to indent the material while maintaining the reference probe substantially under the hand pressure or weight of the housing allowing evaluation of a property of the material related to indentation of the material by the probe. Force can be generated by a voice coil in a magnet structure to the end of which the test probe is connected and supported in the magnet structure by a flexure, opposing flexures, a linear translation stage, or a linear bearing. Optionally, a measurement unit containing the test probe and reference probe is connected to a base unit with a wireless connection, allowing in the field material testing.

  14. Driver electronic device use in 2008

    DOT National Transportation Integrated Search

    2009-09-01

    The 2008 hand-held cell phone use rate translates into 812,000 vehicles being driven by someone using a hand-held cell phone at any given daylight moment.1 It also translates into an estimated 11 percent of the vehicles whose drivers were using some ...

  15. The accuracy of a hand-held navigation system in total knee arthroplasty.

    PubMed

    Loh, Bryan; Chen, Jerry Yongqiang; Yew, Andy Khye Soon; Pang, Hee Nee; Tay, Darren Keng Jin; Chia, Shi-Lu; Lo, Ngai Nung; Yeo, Seng Jin

    2017-03-01

    This study aims to evaluate the effectiveness of a new hand-held navigation system. The authors of this study hypothesize that this navigation system will improve overall lower limb alignment and implant placement without causing a delay in surgery. Two hundred consecutive patients diagnosed with tricompartmental osteoarthritis and underwent total knee arthroplasty by a senior surgeon were included in this study. One hundred patients underwent TKA using the hand-held navigation system, while the other 100 patients underwent TKA using the conventional technique. The primary outcomes of this study were the overall alignment of the lower limb and the position of the components. This was determined radiologically using the: (1) Hip-Knee-Ankle angle (HKA) for lower limb alignment; (2) Coronal Femoral-Component angle (CFA); and (3) Coronal Tibia-Component angle (CTA) for component position. Normal alignment was taken as 180° ± 3° for the HKA and 90° ± 3° for both the CFA and CTA. For the CFA, the proportion of outliers was 7 and 17% in the hand-held navigation and conventional group, respectively (p = 0.030). For the HKA and CTA, there was no difference in the proportion of outliers between the two groups. The duration of surgery was 73 ± 9 min and 87 ± 15 min in the hand-held navigation and conventional group, respectively (p < 0.001). This hand-held navigation system is an effective intraoperative tool for reducing the proportion of outliers for femoral implant placement as well as the duration of surgery. The authors conclude that it can be considered for use to check femoral implant placement intra-operatively. III.

  16. Evaluation of a focussed protocol for hand-held echocardiography and computer-assisted auscultation in detecting latent rheumatic heart disease in scholars.

    PubMed

    Zühlke, Liesl J; Engel, Mark E; Nkepu, Simpiwe; Mayosi, Bongani M

    2016-08-01

    Introduction Echocardiography is the diagnostic test of choice for latent rheumatic heart disease. The utility of echocardiography for large-scale screening is limited by high cost, complex diagnostic protocols, and time to acquire multiple images. We evaluated the performance of a brief hand-held echocardiography protocol and computer-assisted auscultation in detecting latent rheumatic heart disease with or without pathological murmur. A total of 27 asymptomatic patients with latent rheumatic heart disease based on the World Heart Federation criteria and 66 healthy controls were examined by standard cardiac auscultation to detect pathological murmur. Hand-held echocardiography using a focussed protocol that utilises one view - that is, the parasternal long-axis view - and one measurement - that is, mitral regurgitant jet - and a computer-assisted auscultation utilising an automated decision tool were performed on all patients. The sensitivity and specificity of computer-assisted auscultation in latent rheumatic heart disease were 4% (95% CI 1.0-20.4%) and 93.7% (95% CI 84.5-98.3%), respectively. The sensitivity and specificity of the focussed hand-held echocardiography protocol for definite rheumatic heart disease were 92.3% (95% CI 63.9-99.8%) and 100%, respectively. The test reliability of hand-held echocardiography was 98.7% for definite and 94.7% for borderline disease, and the adjusted diagnostic odds ratios were 1041 and 263.9 for definite and borderline disease, respectively. Computer-assisted auscultation has extremely low sensitivity but high specificity for pathological murmur in latent rheumatic heart disease. Focussed hand-held echocardiography has fair sensitivity but high specificity and diagnostic utility for definite or borderline rheumatic heart disease in asymptomatic patients.

  17. Three-dimensional fluorescence-enhanced optical tomography using a hand-held probe based imaging system

    PubMed Central

    Ge, Jiajia; Zhu, Banghe; Regalado, Steven; Godavarty, Anuradha

    2008-01-01

    Hand-held based optical imaging systems are a recent development towards diagnostic imaging of breast cancer. To date, all the hand-held based optical imagers are used to perform only surface mapping and target localization, but are not capable of demonstrating tomographic imaging. Herein, a novel hand-held probe based optical imager is developed towards three-dimensional (3-D) optical tomography studies. The unique features of this optical imager, which primarily consists of a hand-held probe and an intensified charge coupled device detector, are its ability to; (i) image large tissue areas (5×10 sq. cm) in a single scan, (ii) perform simultaneous multiple point illumination and collection, thus reducing the overall imaging time; and (iii) adapt to varying tissue curvatures, from a flexible probe head design. Experimental studies are performed in the frequency domain on large slab phantoms (∼650 ml) using fluorescence target(s) under perfect uptake (1:0) contrast ratios, and varying target depths (1–2 cm) and X-Y locations. The effect of implementing simultaneous over sequential multiple point illumination towards 3-D tomography is experimentally demonstrated. The feasibility of 3-D optical tomography studies has been demonstrated for the first time using a hand-held based optical imager. Preliminary fluorescence-enhanced optical tomography studies are able to reconstruct 0.45 ml target(s) located at different target depths (1–2 cm). However, the depth recovery was limited as the actual target depth increased, since only reflectance measurements were acquired. Extensive tomography studies are currently carried out to determine the resolution and performance limits of the imager on flat and curved phantoms. PMID:18697559

  18. Three-dimensional fluorescence-enhanced optical tomography using a hand-held probe based imaging system.

    PubMed

    Ge, Jiajia; Zhu, Banghe; Regalado, Steven; Godavarty, Anuradha

    2008-07-01

    Hand-held based optical imaging systems are a recent development towards diagnostic imaging of breast cancer. To date, all the hand-held based optical imagers are used to perform only surface mapping and target localization, but are not capable of demonstrating tomographic imaging. Herein, a novel hand-held probe based optical imager is developed towards three-dimensional (3-D) optical tomography studies. The unique features of this optical imager, which primarily consists of a hand-held probe and an intensified charge coupled device detector, are its ability to; (i) image large tissue areas (5 x 10 sq. cm) in a single scan, (ii) perform simultaneous multiple point illumination and collection, thus reducing the overall imaging time; and (iii) adapt to varying tissue curvatures, from a flexible probe head design. Experimental studies are performed in the frequency domain on large slab phantoms (approximately 650 ml) using fluorescence target(s) under perfect uptake (1:0) contrast ratios, and varying target depths (1-2 cm) and X-Y locations. The effect of implementing simultaneous over sequential multiple point illumination towards 3-D tomography is experimentally demonstrated. The feasibility of 3-D optical tomography studies has been demonstrated for the first time using a hand-held based optical imager. Preliminary fluorescence-enhanced optical tomography studies are able to reconstruct 0.45 ml target(s) located at different target depths (1-2 cm). However, the depth recovery was limited as the actual target depth increased, since only reflectance measurements were acquired. Extensive tomography studies are currently carried out to determine the resolution and performance limits of the imager on flat and curved phantoms.

  19. Library service delivery via hand-held computers--the right information at the point of care.

    PubMed

    Peterson, Mary

    2004-03-01

    Today's health and medical librarians are well aware of the move towards evidence-based clinical practice which has emerged during the past decade. Hand-in-hand with this trend is the need for health practitioners to have access to the best possible evidence to help them in their clinical decision making. Libraries have a key role in the provision of information to their clients, and this means keeping abreast, not only of the various information sources available, but also the means by which those sources may be used. This paper will examine the effects that the hand-held computer is having on the work practices of our clients-library users. It is hoped that the paper will give an insight into the various types of library material which are suitable for use with hand-held devices, and an understanding of their advantages and limitations.

  20. Data Center Energy Efficiency Technologies and Methodologies: A Review of Commercial Technologies and Recommendations for Application to Department of Defense Systems

    DTIC Science & Technology

    2015-11-01

    provided by a stand-alone desktop or hand held computing device. This introduces into the discussion a large number of mobile , tactical command...control, communications, and computer (C4) systems across the Services. A couple of examples are mobile command posts mounted on the back of an M1152... infrastructure (DCPI). This term encompasses on-site backup generators, switchgear, uninterruptible power supplies (UPS), power distribution units

  1. The Nose Knows: Developing Advanced Chemical Sensors for the Remote Detection of Improvised Explosive Devices in 2030

    DTIC Science & Technology

    2009-04-01

    noses”, High Frequency Quartz Crystal Microbalance (HF- QCM ), and fluorescent polymer based sensors . The combination of the chemical binding of molecules...nose and uses HF- QCM technology. The hand-held product consists of a sampling unit and analyzer and contains an array of sensors and coatings which...i AU/ACSC/2763/2008-09 AIR COMMAND AND STAFF COLLEGE AIR UNIVERSITY THE NOSE KNOWS: DEVELOPING ADVANCED CHEMICAL SENSORS FOR THE REMOTE

  2. Rapid limit tests for metal impurities in pharmaceutical materials by X-ray fluorescence spectroscopy using wavelet transform filtering.

    PubMed

    Arzhantsev, Sergey; Li, Xiang; Kauffman, John F

    2011-02-01

    We introduce a new method for analysis of X-ray fluorescence (XRF) spectra based on continuous wavelet transform filters, and the method is applied to the determination of toxic metals in pharmaceutical materials using hand-held XRF spectrometers. The method uses the continuous wavelet transform to filter the signal and noise components of the spectrum. We present a limit test that compares the wavelet domain signal-to-noise ratios at the energies of the elements of interest to an empirically determined signal-to-noise decision threshold. The limit test is advantageous because it does not require the user to measure calibration samples prior to measurement, though system suitability tests are still recommended. The limit test was evaluated in a collaborative study that involved five different hand-held XRF spectrometers used by multiple analysts in six separate laboratories across the United States. In total, more than 1200 measurements were performed. The detection limits estimated for arsenic, lead, mercury, and chromium were 8, 14, 20, and 150 μg/g, respectively.

  3. Engineering issues for hand-held sensing devices, with examples

    NASA Astrophysics Data System (ADS)

    Freiwald, David A.; Freiwald, Joyce

    1994-03-01

    It is now U.S. defense policy that there will be no new platform starts. The emphasis for platforms will be on O&M cost reduction, life-extension improvements, and force-multiplier- device upgrades. There is also an increasing emphasis on hand-held force-multiplier devices for individuals, which is the focus of this paper. Engineering issues include operations analysis, weight, cube, cost, prime power, ease of use, data storage, reliability, fault tolerance, data communications and human factors. Two examples of hand-held devices are given. Applications include USMC, Army, SOCOM, DEA, FBI, SS, Border Patrol and others. Barriers to adoption of such technology are also discussed.

  4. Attentionally splitting the mass distribution of hand-held rods.

    PubMed

    Burton, G; Turvey, M T

    1991-08-01

    Two experiments on the length-perception capabilities of effortful or dynamic touch differed only in terms of what the subject intended to perceive, while experimental conditions and apparatus were held constant. In each trial, a visually occluded rod was held as still as possible by the subject at an intermediate position. For two thirds of the trials, a weight was attached to the rod above or below the hand. In Experiment 1, in which the subject's task was to perceive the distance reachable with the portion of the rod forward of the hand, perceived extent was a function of the first moment of the mass distribution associated with the forward portion of the rod, and indifferent to the first moment of the entire rod. In Experiment 2, in which the task was to perceive the distance reachable with the entire rod if it was held at an end, the pattern of results was reversed. These results indicate the capability of selective sensitivity to different aspects of a hand-held object's mass distribution, without the possibility of differential exploration specific to these two tasks. Results are discussed in relation to possible roles of differential information, intention, and self-organization in the explanations of selective perceptual abilities.

  5. Use of a hand-held meter for detecting subclinical ketosis in dairy cows.

    PubMed

    Voyvoda, Huseyin; Erdogan, Hasan

    2010-12-01

    The Optium Xceed is a new hand-held meter for determining blood β-hydroxybutyrate (BHBA) and glucose in human medicine. The objective of this study was to compare BHBA and glucose results obtained using the hand-held meter with those results made with a laboratory method and to evaluate its usefulness as a cowside test in the diagnosis of subclinical ketosis (SCK) in dairy cows. Seventy-eight blood samples from clinically healthy Holstein cows between 5 and 60 days post-calving were analysed. BHBA and glucose values were significantly higher with the hand-held meter versus laboratory methods. Correlation coefficients (r) for BHBA and glucose with the Optium Xceed versus laboratory methods were 0.97 and 0.63, respectively. Based on Bland-Altman plot and Passing-Bablok regression, agreement between two methods was good for BHBA but the agreement for glucose was only fair. When SCK was defined as plasma BHBA levels ≥ 1200 μmol/L, the sensitivity and specificity of the hand-held meter ketone testing in determining SCK were 85% and 94%, respectively. Raising the threshold of the laboratory method to ≥ 1400 μmol/L, the sensitivity and specificity incremented to 0.90 and 0.98, respectively. In conclusion, the blood ketone-monitoring device can be used as a rapid and reliable diagnostic test to detect SCK under field conditions. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. The United States Particle Accelerator School: Educating the Next Generation of Accelerator Scientists and Engineers

    NASA Astrophysics Data System (ADS)

    Barletta, William A.

    2009-03-01

    Only a handful of universities in the US offer any formal training in accelerator science. The United States Particle Accelerator School (USPAS) is National Graduate Educational Program that has developed a highly successful educational paradigm that, over the past twenty-years, has granted more university credit in accelerator/beam science and technology than any university in the world. Sessions are held twice annually, hosted by major US research universities that approve course credit, certify the USPAS faculty, and grant course credit. The USPAS paradigm is readily extensible to other rapidly developing, cross-disciplinary research areas such as high energy density physics.

  7. Transport suction apparatus and absorption materials evaluation

    NASA Technical Reports Server (NTRS)

    Krupa, Debra T.; Gosbee, John

    1991-01-01

    The specific objectives were as follows. The effectiveness and function was evaluated of the hand held, manually powered v-vac for suction during microgravity. The function was evaluated of the battery powered laerdal suction unit in microgravity. The two units in control of various types of simulated bodily fluids were compared. Various types of tubing and attachments were evaluated which are required to control the collection of bodily fluids during transport. Various materials were evaluated for absorption of simulated bodily fluids. And potential problems were identified for waste management and containment of secretions and fluids during transport. Test procedures, results, and conclusions are briefly discussed.

  8. 49 CFR 392.82 - Using a hand-held mobile telephone.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Definitions. For the purpose of this section only, driving means operating a commercial motor vehicle on a... SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS DRIVING OF.... (a)(1) No driver shall use a hand-held mobile telephone while driving a CMV. (2) No motor carrier...

  9. 49 CFR 392.82 - Using a hand-held mobile telephone.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Definitions. For the purpose of this section only, driving means operating a commercial motor vehicle on a... SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS DRIVING OF.... (a)(1) No driver shall use a hand-held mobile telephone while driving a CMV. (2) No motor carrier...

  10. 49 CFR 392.82 - Using a hand-held mobile telephone.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Definitions. For the purpose of this section only, driving means operating a commercial motor vehicle on a... SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS DRIVING OF.... (a)(1) No driver shall use a hand-held mobile telephone while driving a CMV. (2) No motor carrier...

  11. 30 CFR 56.12033 - Hand-held electric tools.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...

  12. 30 CFR 56.12033 - Hand-held electric tools.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...

  13. 30 CFR 56.12033 - Hand-held electric tools.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...

  14. 30 CFR 56.12033 - Hand-held electric tools.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...

  15. 30 CFR 56.12033 - Hand-held electric tools.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...

  16. Survey reveals public open to ban on hand-held cell phone use and texting.

    DOT National Transportation Integrated Search

    2013-01-01

    A study performed by the Bureau of Transportation Statistics : (BTS) reveals that the public is open to a ban on : hand-held cell phone use while driving. The study is based : on data from 2009s Omnibus Household Survey (OHS), : which is administe...

  17. Ultraviolet Source For Testing Hydrogen-Fire Detectors

    NASA Technical Reports Server (NTRS)

    Hall, Gregory A.; Larson, William E.; Youngquist, Robert C.; Moerk, John S.; Haskell, William D.; Cox, Robert B.; Polk, Jimmy D.; Stout, Stephen J.; Strobel, James P.

    1995-01-01

    Hand-held portable unit emits ultraviolet light similar to that emitted by hydrogen burning in air. Developed for use in testing optoelectronic hydrogen-fire detectors, which respond to ultraviolet light at wavelengths from 180 to 240 nanometers. Wavelength range unique in that within it, hydrogen fires emit small but detectable amounts of radiation, light from incandescent lamps and Sun almost completely absent, and air sufficiently transmissive to enable detection of hydrogen fire from distance. Consequently, this spectral region favorable for detecting hydrogen fires while minimizing false alarms.

  18. Comparison of Image Generation And Processing Techniques For 3D Reconstruction of The Human Skull

    DTIC Science & Technology

    2001-10-25

    inexpensive Microscribe (3D digitizer) with a standard widely used and expensive CT-Scan and/or MRI for 3D reconstruction of a human skull, which will be... Microscribe 3D digitizing unit and another one using the CT-Scans (2D cross-sections) obtained from a GE scanner. Both models were then subjected to stress...these methods are still elaborate, expensive and not readily accessible. Using the hand-held digitizer, the Microscribe , X, Y and Z coordinates

  19. Handheld Searchlight

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Streamlite Inc. reengineered the NASA searchlight for commercial use. The brightest hand-held light yet produced is result of Xenon-arc lights developed as solar simulators at Johnson Space Center. Intense battery powered searchlight is rated a million candlepower - 50 times brighter than high beam headlights of a car, and weighs only 7 pounds. Lifetime of xenon lamp is at least 200 hours at maximum intensity. Retail cost is under $400.00. Company has introduced smaller unit in shape of a flashlight, produces 20,000 candlepower and costs approximately $60.00.

  20. 78 FR 20695 - Walk-Through Metal Detectors and Hand-Held Metal Detectors Test Method Validation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-05

    ... Detectors and Hand-Held Metal Detectors Test Method Validation AGENCY: National Institute of Justice, DOJ... ensure that the test methods in the standards are properly documented, NIJ is requesting proposals (including price quotes) for test method validation efforts from testing laboratories. NIJ is also seeking...

  1. How to use hand-held computers to evaluate wood drying.

    Treesearch

    Howard N. Rosen; Darrell S. Martin

    1985-01-01

    Techniques have been developed to evaluate end generate wood drying curves with hand-held computers (3-5K memory). Predictions of time to dry to a specific moisture content, drying rates, and other characteristics of wood drying curves can be made. The paper describes the development of programs and illustrates their use.

  2. Epilepsy Forewarning Using A Hand-Held Device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hively, LM

    2005-02-21

    Over the last decade, ORNL has developed and patented a novel approach for forewarning of a large variety of machine and biomedical events. The present implementation uses desktop computers to analyze archival data. This report describes the next logical step in this effort, namely use of a hand-held device for the analysis.

  3. 75 FR 59301 - Self-Regulatory Organizations; Notice of Filing and Immediate Effectiveness of Proposed Rule...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-27

    ... makes clear what type of information may be communicated to and from hand-held devices. \\8\\ 15 U.S.C...\\ NYSE approved portable telephones,\\6\\ or through a written electronic communication from the Floor brokers' hand-held device as permitted by the NYSE's ``Wireless Data Communications Initiatives...

  4. Multi-Sensor Systems Development for UXO Detection and Discrimination: Hand-Held Dual Magnetic/Electromagnetic Induction Sensor

    DTIC Science & Technology

    2008-04-01

    5 Fluxgate magnetometer ... magnetometer into digital format, and transmitted as a single serial data string to log the Cs and fluxgate magnetometer data. After procurement...Hardware The system hardware comprises an EMI sensor, Cs vapor magnetometer , fluxgate magnetometer , hand-held data acquisition computer, integrated

  5. Hand-held Calculators: Past, Present, and Future

    ERIC Educational Resources Information Center

    Bell, Max; And Others

    1977-01-01

    Recommendations of several publications with regard to the use of hand-held calculators in the mathematics curriculum are presented. Relevant portions of the NACOME and Euclid Conference reports are cited as well as a report to NSF and recommendations from an NIE/NSF conference. Recommendations support expanded use of, and research concerning,…

  6. Online Responses towards Parental Rearing Styles Regarding Hand-Held Devices

    ERIC Educational Resources Information Center

    Geng, Gretchen; Disney, Leigh

    2014-01-01

    This article reviewed the literature on parental rearing styles and used responses from an online discussion forum to investigate people's opinions towards parental rearing styles and strategies when children use hand-held devices. Critical discourse analysis (CDA) was used as an analysis method via micro, meso and macro multi-level…

  7. 33 CFR 175.130 - Visual distress signals accepted.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... red flare (160.024 or 160.036) meets both day and night requirements. Three hand held orange smoke (160.037) with one electric distress light (161.013) meet both day and night requirements. Table 175... Number required 160.021 Hand Held Red Flare Distress Signals 3 Day and Night 3 160.022 Floating Orange...

  8. 77 FR 40637 - Honeywell International, Scanning and Mobility Division, Formerly Known as Hand Held Products...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-10

    ..., Scanning and Mobility Division, Formerly Known as Hand Held Products, Inc., Including On-Site Leased Workers From Manpower, Skaneatelles Falls, NY; Amended Certification Regarding Eligibility To Apply for...''), 19 U.S.C. 2273, the Department of Labor issued a Certification of Eligibility to Apply for Worker...

  9. 49 CFR 177.804 - Compliance with Federal Motor Carrier Safety Regulations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... require texting while driving. (c) Prohibition against the use of hand-held mobile telephones. In... those regulations apply. (b) Prohibition against texting. In accordance with § 392.80 of the FMCSRs a... 42 CFR part 73 may not engage in, allow, or require use of a hand-held mobile telephone while driving...

  10. A new approach for the screening of carotid lesions: a 'fast-track' method with the use of new generation hand-held ultrasound devices.

    PubMed

    Aboyans, V; Lacroix, P; Jeannicot, A; Guilloux, J; Bertin, F; Laskar, M

    2004-09-01

    We assessed the usefulness of fast-track neck sonography with a new-generation hand-held ultrasound scanner in the detection of > or =60% carotid stenosis. Patients with a past history of atherosclerotic disease or presence of risk factors were enrolled. All had fast-track carotid screening with a hand-held ultrasound scanner. Initial assessment was performed with our quick imaging protocol. A second examiner performed a conventional complete carotid duplex as gold-standard. We enrolled 197 consecutive patients with a mean age of 67 years (range 35-94). A carotid stenosis >60% was detected in 13 cases (6%). The sensitivity, specificity, positive and negative predictive value of fast-track sonography was 100%, 64%, 17% and 100%, respectively. Concomitant power Doppler imaging during the fast-track method did not improve accuracy. The use of a fast-track method with a hand-held ultrasound device can reduce the number of unnecessary carotid Duplex and enhance the screening efficiency without missing significant carotid stenoses.

  11. Prediction of essential oil content of oregano by hand-held and Fourier transform NIR spectroscopy.

    PubMed

    Camps, Cédric; Gérard, Marianne; Quennoz, Mélanie; Brabant, Cécile; Oberson, Carine; Simonnet, Xavier

    2014-05-01

    In the framework of a breeding programme, the analysis of hundreds of oregano samples to determine their essential oil content (EOC) is time-consuming and expensive in terms of labour. Therefore developing a new method that is rapid, accurate and less expensive to use would be an asset to breeders. The aim of the present study was to develop a method based on near-inrared (NIR) spectroscopy to determine the EOC of oregano dried powder. Two spectroscopic approaches were compared, the first using a hand-held NIR device and the second a Fourier transform (FT) NIR spectrometer. Hand-held NIR (1000-1800 nm) measurements and partial least squares regression allowed the determination of EOC with R² and SEP values of 0.58 and 0.81 mL per 100 g dry matter (DM) respectively. Measurements with FT-NIR (1000-2500 nm) allowed the determination of EOC with R² and SEP values of 0.91 and 0.68 mL per 100 g DM respectively. RPD, RER and RPIQ values for the model implemented with FT-NIR data were satisfactory for screening application, while those obtained with hand-held NIR data were below the level required to consider the model as enough accurate for screening application. The FT-NIR approach allowed the development of an accurate model for EOC prediction. Although the hand-held NIR approach is promising, it needs additional development before it can be used in practice. © 2013 Society of Chemical Industry.

  12. Hand-arm vibration disorder among grass-cutter workers in Malaysia.

    PubMed

    Azmir, Nor Azali; Ghazali, Mohd Imran; Yahya, Musli Nizam; Ali, Mohamad Hanafi

    2016-09-01

    Prolonged exposure to hand-transmitted vibration from grass-cutting machines has been associated with increasing occurrences of symptoms and signs of occupational diseases related to hand-arm vibration syndrome (HAVS). A cross-sectional study was carried out using an adopted HAVS questionnaire on hand-arm vibration exposure and symptoms distributed to 168 male workers from the grass and turf maintenance industry who use hand-held grass-cutting machines as part of their work. The prevalence ratio and symptom correlation to HAVS between high and low-moderate exposure risk groups were evaluated. There were positive HAVS symptoms relationships between the low-moderate exposure group and the high exposure group among hand-held grass-cutting workers. The prevalence ratio was considered high because there were indicators that fingers turned white and felt numb, 3.63, 95% CI [1.41, 9.39] and 4.24, 95% CI [2.18, 8.27], respectively. Less than 14.3% of workers stated that they were aware of the occupational hand-arm vibration, and it seemed to be related to the finger blanching and numbness. The results suggest that HAVS is under-diagnosed in Malaysia, especially in the agricultural sectors. More information related to safety and health awareness programmes for HAVS exposure is required among hand-held grass-cutting workers.

  13. 75 FR 59753 - Self-Regulatory Organizations; Notice of Filing and Immediate Effectiveness of Proposed Rule...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-28

    ... makes clear what type of information may be communicated to and from hand-held devices. \\8\\ 15 U.S.C... using a wired telephone line,\\5\\ NYSE Amex approved portable telephones,\\6\\ or through a written electronic communication from the Floor brokers' hand-held device as permitted by the NYSE Amex's ``Wireless...

  14. Issues Arising on the Use of Hand-Held Calculators in Schools.

    ERIC Educational Resources Information Center

    D'Ambrosio, Ubiratan

    This paper notes three objections to the use of hand-held calculators in schools: they would (1) block reasoning, (2) make individuals machine-dependent, and (3) broaden the gap between developed and underdeveloped nations. Each is addressed, with specific examples used to refute them. The belief is strongly expressed that calculators can aid in…

  15. Chosen Striking Location and the User-Tool-Environment System

    ERIC Educational Resources Information Center

    Wagman, Jeffrey B.; Taylor, Kona R.

    2004-01-01

    Controlling a hand-held tool requires that the tool user bring the tool into contact with an environmental surface in a task-appropriate manner. This, in turn, requires applying muscular forces so as to overcome how the object resists being moved about its various axes. Perceived properties of hand-held objects tend to be constrained by inertial…

  16. Field evaluation of indoor thermal fog and ultra-low volume applications for control of Aedes aegypti, in Thailand

    USDA-ARS?s Scientific Manuscript database

    Efficacies of a hand-held thermal fogger (PatriotTM) and hand-held Ultra-low volume (ULV) sprayer (TwisterTM) with combinations of two different adulticides and an insect growth regulator (pyriproxyfen) were field assessed and compared for their impact on reducing dengue vector populations in Thaila...

  17. 46 CFR 34.20-20 - Discharge outlets-T/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... least one mounted foam appliance shall be provided for each station that is required in § 34.20-15(c). (c) The number of hand-held appliances provided shall be at least equal to the number of hose outlets at the two foam stations having the most hose outlets. Hand-held appliances shall be stowed in a well...

  18. Development of a minimum performance standard for hand-held fire extinguishers as a replacement for Halon 1211 on civilian transport category aircraft

    DOT National Transportation Integrated Search

    2002-08-01

    One or more Halon 1211 hand-held fire extinguishers are specified in Federal Aviation Regulation (FAR) Part 25.851 as a requirement on transport category aircraft with 31 or more seats. Halon 1211 has been linked to the destruction of the ozone layer...

  19. Hand-Held Calculators in the Classroom: A Review of the Research.

    ERIC Educational Resources Information Center

    Parkhurst, Scott

    This report surveys many of the recent investigations on calculators and their use in mathematics education. The review notes that the widespread availability of hand-held calculators and their affordability has led to their consideration as a viable tool to aid in mathematics instruction. The studies reviewed suggest that many questions are still…

  20. Hand-Held Ultrasonic Instrument for Reading Matrix Symbols

    NASA Technical Reports Server (NTRS)

    Schramm, Harry F.; Kula, John P.; Gurney, John W.; Lior, Ephraim D.

    2008-01-01

    A hand-held instrument that would include an ultrasonic camera has been proposed as an efficient means of reading matrix symbols. The proposed instrument could be operated without mechanical raster scanning. All electronic functions from excitation of ultrasonic pulses through final digital processing for decoding matrix symbols would be performed by dedicated circuitry within the single, compact instrument housing.

  1. High-nitrogen-based pyrotechnics: longer- and brighter-burning, perchlorate-free, red-light illuminants for military and civilian applications.

    PubMed

    Sabatini, Jesse J; Nagori, Amita V; Chen, Gary; Chu, Phillip; Damavarapu, Reddy; Klapötke, Thomas M

    2012-01-09

    The full-up prototype testing of perchlorate-free, hand-held, signal illuminants for the US Army's M126A1 red star parachute hand-held signal is described. Compared to the perchlorate-containing control, the disclosed illuminants yielded excellent stabilities toward various ignition stimuli while offering superior pyrotechnic performance. Militarily, the illuminants provided further evidence that development of smaller hand-held signal items in an environmentally conscious way is a realistic and obtainable goal. The results are also important from the perspective of civilian fireworks, as the development of brighter, longer-burning, and environmentally compatible red-light-emitting pyrotechnics is now possible. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. 3D indoor modeling using a hand-held embedded system with multiple laser range scanners

    NASA Astrophysics Data System (ADS)

    Hu, Shaoxing; Wang, Duhu; Xu, Shike

    2016-10-01

    Accurate three-dimensional perception is a key technology for many engineering applications, including mobile mapping, obstacle detection and virtual reality. In this article, we present a hand-held embedded system designed for constructing 3D representation of structured indoor environments. Different from traditional vehicle-borne mobile mapping methods, the system presented here is capable of efficiently acquiring 3D data while an operator carrying the device traverses through the site. It consists of a simultaneous localization and mapping(SLAM) module, a 3D attitude estimate module and a point cloud processing module. The SLAM is based on a scan matching approach using a modern LIDAR system, and the 3D attitude estimate is generated by a navigation filter using inertial sensors. The hardware comprises three 2D time-flight laser range finders and an inertial measurement unit(IMU). All the sensors are rigidly mounted on a body frame. The algorithms are developed on the frame of robot operating system(ROS). The 3D model is constructed using the point cloud library(PCL). Multiple datasets have shown robust performance of the presented system in indoor scenarios.

  3. Comparison of light transmittance in different thicknesses of zirconia under various light curing units

    PubMed Central

    Egilmez, Ferhan; Ergun, Gulfem

    2012-01-01

    PURPOSE The objective of this study was to compare the light transmittance of zirconia in different thicknesses using various light curing units. MATERIALS AND METHODS A total of 21 disc-shaped zirconia specimens (5 mm in diameter) in different thicknesses (0.3, 0.5 and 0.8 mm) were prepared. The light transmittance of the specimens under three different light-curing units (quartz tungsten halogen, light-emitting diodes and plasma arc) was compared by using a hand-held radiometer. Statistical significance was determined using two-way ANOVA (α=.05). RESULTS ANOVA revealed that thickness of zirconia and light curing unit had significant effects on light transmittance (P<.001). CONCLUSION Greater thickness of zirconia results in lower light transmittance. Light-emitting diodes light-curing units might be considered as effective as Plasma arc light-curing units or more effective than Quartz-tungsten-halogen light-curing units for polymerization of the resin-based materials. PMID:22737314

  4. Hand-held internet tablets for school-based data collection.

    PubMed

    Denny, Simon J; Milfont, Taciano L; Utter, Jennifer; Robinson, Elizabeth M; Ameratunga, Shanthi N; Merry, Sally N; Fleming, Theresa M; Watson, Peter D

    2008-07-26

    In the last 20 years, researchers have been using computer self-administered questionnaires to gather data on a wide range of adolescent health related behaviours. More recently, researchers collecting data in schools have started to use smaller hand-held computers for their ease of use and portability. The aim of this study is to describe a new technology with wi-fi enabled hand-held internet tablets and to compare adolescent preferences of laptop computers or hand-held internet tablets in administering a youth health and well-being questionnaire in a school setting. A total of 177 students took part in a pilot study of a national youth health and wellbeing survey. Students were randomly assigned to internet tablets or laptops at the start of the survey and were changed to the alternate mode of administration about half-way through the questionnaire. Students at the end of the questionnaire were asked which of the two modes of administration (1) they preferred, (2) was easier to use, (3) was more private and confidential, and (4) was easier to answer truthfully. Many students expressed no preference between laptop computers or internet tablets. However, among the students who expressed a preference between laptop computers or internet tablets, the majority of students found the internet tablets more private and confidential (p < 0.001) and easier to answer questions truthfully (p < 0.001) compared to laptop computers. This study demonstrates that using wi-fi enabled hand-held internet tablets is a feasible methodology for school-based surveys especially when asking about sensitive information.

  5. Hand-held internet tablets for school-based data collection

    PubMed Central

    Denny, Simon J; Milfont, Taciano L; Utter, Jennifer; Robinson, Elizabeth M; Ameratunga, Shanthi N; Merry, Sally N; Fleming, Theresa M; Watson, Peter D

    2008-01-01

    Background In the last 20 years, researchers have been using computer self-administered questionnaires to gather data on a wide range of adolescent health related behaviours. More recently, researchers collecting data in schools have started to use smaller hand-held computers for their ease of use and portability. The aim of this study is to describe a new technology with wi-fi enabled hand-held internet tablets and to compare adolescent preferences of laptop computers or hand-held internet tablets in administering a youth health and well-being questionnaire in a school setting. Methods A total of 177 students took part in a pilot study of a national youth health and wellbeing survey. Students were randomly assigned to internet tablets or laptops at the start of the survey and were changed to the alternate mode of administration about half-way through the questionnaire. Students at the end of the questionnaire were asked which of the two modes of administration (1) they preferred, (2) was easier to use, (3) was more private and confidential, and (4) was easier to answer truthfully. Results Many students expressed no preference between laptop computers or internet tablets. However, among the students who expressed a preference between laptop computers or internet tablets, the majority of students found the internet tablets more private and confidential (p < 0.001) and easier to answer questions truthfully (p < 0.001) compared to laptop computers. Conclusion This study demonstrates that using wi-fi enabled hand-held internet tablets is a feasible methodology for school-based surveys especially when asking about sensitive information. PMID:18710505

  6. Applying Hand-Held 3D Printing Technology to the Teaching of VSEPR Theory

    ERIC Educational Resources Information Center

    Dean, Natalie L.; Ewan, Corrina; McIndoe, J. Scott

    2016-01-01

    The use of hand-held 3D printing technology provides a unique and engaging approach to learning VSEPR theory by enabling students to draw three-dimensional depictions of different molecular geometries, giving them an appreciation of the shapes of the building blocks of complex molecular structures. Students are provided with 3D printing pens and…

  7. A Cheap, Semiquantitative Hand-Held Conductivity Tester.

    ERIC Educational Resources Information Center

    Zawacky, Susan K. S.

    1995-01-01

    Describes a design for a hand-held conductivity tester powered by a 9V battery that gives semi-quantitative results for aqueous electrolyte solutions of concentrations ranging from 0.001 M to 0.1 M. The tester uses a bar-graph LED driven by an LM3914 integrated circuit to indicate the level of conductivity. A list of parts, procedures, and results…

  8. The Weak Link HP-41C hand-held calculator program

    Treesearch

    Ross A. Phillips; Penn A. Peters; Gary D. Falk

    1982-01-01

    The Weak Link hand-held calculator program (HP-41C) quickly analyzes a system for logging production and costs. The production equations model conventional chain saw, skidder, loader, and tandemaxle truck operations in eastern mountain areas. Production of each function of the logging system may be determined so that the system may be balanced for minimum cost. The...

  9. Spray distribution evaluation of different settings of a hand-held-trolley sprayer used in greenhouse tomato crops.

    PubMed

    Llop, Jordi; Gil, Emilio; Gallart, Montserrat; Contador, Felipe; Ercilla, Mireia

    2016-03-01

    Hand-held-trolley sprayers have recently been promoted to improve spray application techniques in greenhouses in south-eastern Spain. However, certain aspects remain to be improved. A modified hand-held-trolley sprayer was evaluated under two different canopy conditions (high and low canopy density) and with several sprayer settings (nozzle type, air assistance and spray volume). In this study, the deposition, coverage and uniformity of distribution of the spray on the canopy have been assessed. The deposition on leaves was significantly higher when flat-fan nozzles and air assistance were used at both high and low spray volumes. No differences were detected between the reference system at a high spray volume and the modified trolley at a low spray volume. Flat-fan nozzles with air assistance increased penetrability into the canopy. Air assistance and flat-fan nozzles allow volume rates to be reduced while maintaining or improving spray quality distribution. The working parameters of hand-held sprayers must be considered to reduce environmental risk and increase the efficacy of the spraying process. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  10. Gen-2 hand-held optical imager towards cancer imaging: reflectance and transillumination phantom studies.

    PubMed

    Gonzalez, Jean; Roman, Manuela; Hall, Michael; Godavarty, Anuradha

    2012-01-01

    Hand-held near-infrared (NIR) optical imagers are developed by various researchers towards non-invasive clinical breast imaging. Unlike these existing imagers that can perform only reflectance imaging, a generation-2 (Gen-2) hand-held optical imager has been recently developed to perform both reflectance and transillumination imaging. The unique forked design of the hand-held probe head(s) allows for reflectance imaging (as in ultrasound) and transillumination or compressed imaging (as in X-ray mammography). Phantom studies were performed to demonstrate two-dimensional (2D) target detection via reflectance and transillumination imaging at various target depths (1-5 cm deep) and using simultaneous multiple point illumination approach. It was observed that 0.45 cc targets were detected up to 5 cm deep during transillumination, but limited to 2.5 cm deep during reflectance imaging. Additionally, implementing appropriate data post-processing techniques along with a polynomial fitting approach, to plot 2D surface contours of the detected signal, yields distinct target detectability and localization. The ability of the gen-2 imager to perform both reflectance and transillumination imaging allows its direct comparison to ultrasound and X-ray mammography results, respectively, in future clinical breast imaging studies.

  11. An efficient solid modeling system based on a hand-held 3D laser scan device

    NASA Astrophysics Data System (ADS)

    Xiong, Hanwei; Xu, Jun; Xu, Chenxi; Pan, Ming

    2014-12-01

    The hand-held 3D laser scanner sold in the market is appealing for its port and convenient to use, but price is expensive. To develop such a system based cheap devices using the same principles as the commercial systems is impossible. In this paper, a simple hand-held 3D laser scanner is developed based on a volume reconstruction method using cheap devices. Unlike convenient laser scanner to collect point cloud of an object surface, the proposed method only scan few key profile curves on the surface. Planar section curve network can be generated from these profile curves to construct a volume model of the object. The details of design are presented, and illustrated by the example of a complex shaped object.

  12. Hands beat machines for collecting native seed

    Treesearch

    Mary Ann Davies; Scott Jensen

    2008-01-01

    A hedge trimmer (Garden Groom Pro) and a hand-held vacuum (Euro-Pro Shark) were tested to determine whether they might be more effective for collecting the seed of native plants than common hand methods. The common hand methods worked best.

  13. Ultrasonic Maintenance

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The Ultraprobe 2000, manufactured by UE Systems, Inc., Elmsford, NY, is a hand-held ultrasonic system that detects indications of bearing failure by analyzing changes in amplitude. It employs the technology of a prototype ultrasonic bearing-failure monitoring system developed by Mechanical Technology, Inc., Latham, New York and Marshall Space Flight Center (which was based on research into Skylab's gyroscope bearings). Bearings on the verge of failure send ultrasonic signals indicating their deterioration; the Ultraprobe changes these to audible signals. The operator hears the signals and gages their intensity with a meter in the unit.

  14. The effect of inertial loading on wrist postural tremor in essential tremor.

    PubMed

    Héroux, M E; Pari, G; Norman, K E

    2009-05-01

    Determine the effect of inertial loading on the strength of motor unit entrainment and the synergistic/competitive interaction between central and mechanical reflex tremor components in subjects with essential tremor (ET). Twenty-three subjects with ET and 22 controls held their hand in an outstretched position while supporting sub-maximal loads (no-load, 5%, 15% and 25% 1-repetition maximum). Hand postural tremor and wrist extensor neuromuscular activity were recorded. Inertial loading resulted in a reduction in postural tremor in all ET subjects. The largest reduction in tremor amplitude occurred between 5% and 15% loads, which was associated with spectral separation of the mechanical reflex and central tremor components in a large number of ET subjects. Despite an increase in overall neuromuscular activity with inertial loading, EMG tremor spectral power did not increase with loading. The effect of inertial loading on postural tremor amplitude appears to be mediated in large part by its effect on the interaction between mechanical reflex and central tremor components. Also, ET is associated with a constant absolute level of motor unit entrainment. The amplitude of postural tremor is dependent on both central and peripheral factors, with proportionally greater motor unit entrainment occurring at low contraction intensities.

  15. 21 CFR 872.4565 - Dental hand instrument.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental hand instrument. 872.4565 Section 872.4565...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4565 Dental hand instrument. (a) Identification. A dental hand instrument is a hand-held device intended to perform various tasks in general dentistry and...

  16. 21 CFR 872.4565 - Dental hand instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental hand instrument. 872.4565 Section 872.4565...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4565 Dental hand instrument. (a) Identification. A dental hand instrument is a hand-held device intended to perform various tasks in general dentistry and...

  17. 21 CFR 872.4565 - Dental hand instrument.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental hand instrument. 872.4565 Section 872.4565...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4565 Dental hand instrument. (a) Identification. A dental hand instrument is a hand-held device intended to perform various tasks in general dentistry and...

  18. 21 CFR 872.4565 - Dental hand instrument.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental hand instrument. 872.4565 Section 872.4565...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4565 Dental hand instrument. (a) Identification. A dental hand instrument is a hand-held device intended to perform various tasks in general dentistry and...

  19. 21 CFR 872.4565 - Dental hand instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental hand instrument. 872.4565 Section 872.4565...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4565 Dental hand instrument. (a) Identification. A dental hand instrument is a hand-held device intended to perform various tasks in general dentistry and...

  20. So the Kids Are Busy, What Now? Teacher Perceptions of the Use of Hand-Held Game Consoles in West Australian Primary Classrooms

    ERIC Educational Resources Information Center

    O'Rourke, John; Main, Susan; Ellis, Michelle

    2013-01-01

    Games technology in the form of hand-held game consoles (HGCs) when focussed on specific academic skill development has the capacity to engage students in learning and in turn produce positive academic results. This current research explores teacher perceptions of the implementation of HGCs to enhance the development of mental maths skills (namely…

  1. An Examination of Hand-Held Computer-Assisted Instruction on Subtraction Skills for Second Grade Students with Learning and Behavioral Disabilities

    ERIC Educational Resources Information Center

    Nordness, Philip D.; Haverkost, Ann; Volberding, Annette

    2011-01-01

    The effect of a mathematic flashcard application on a hand-held computing device was examined across three individual second grade students with learning and behavioral disabilities. All of the students improved their subtraction scores by an average of 17% as measured by the district-created, curriculum-based assessment. The results of this study…

  2. DataPlus™ - a revolutionary applications generator for DOS hand-held computers

    Treesearch

    David Dean; Linda Dean

    2000-01-01

    DataPlus allows the user to easily design data collection templates for DOS-based hand-held computers that mimic clipboard data sheets. The user designs and tests the application on the desktop PC and then transfers it to a DOS field computer. Other features include: error checking, missing data checks, and sensor input from RS-232 devices such as bar code wands,...

  3. Integrating a Hand Held computer and Stethoscope into a Fetal Monitor

    PubMed Central

    Ahmad Soltani, Mitra

    2009-01-01

    This article presents procedures for modifying a hand held computer or personal digital assistant (PDA) into a versatile device functioning as an electronic stethoscope for fetal monitoring. Along with functioning as an electronic stethoscope, a PDA can provide a useful information source for a medical trainee. Feedback from medical students, residents and interns suggests the device is well accepted by medical trainees. PMID:20165517

  4. 26 CFR 1.1223-1 - Determination of period for which capital assets are held.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Gains and Losses § 1.1223-1 Determination of period for which capital assets are held. (a) The holding... determining gain or loss in the hands of the taxpayer as the property exchanged. However, this rule shall... in part in the hands of the taxpayer for determining gain or loss from a sale or exchange as it would...

  5. 26 CFR 1.1223-1 - Determination of period for which capital assets are held.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Gains and Losses § 1.1223-1 Determination of period for which capital assets are held. (a) The holding... determining gain or loss in the hands of the taxpayer as the property exchanged. However, this rule shall... in part in the hands of the taxpayer for determining gain or loss from a sale or exchange as it would...

  6. 26 CFR 1.1223-1 - Determination of period for which capital assets are held.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Gains and Losses § 1.1223-1 Determination of period for which capital assets are held. (a) The holding... determining gain or loss in the hands of the taxpayer as the property exchanged. However, this rule shall... in part in the hands of the taxpayer for determining gain or loss from a sale or exchange as it would...

  7. 26 CFR 1.1223-1 - Determination of period for which capital assets are held.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Gains and Losses § 1.1223-1 Determination of period for which capital assets are held. (a) The holding... determining gain or loss in the hands of the taxpayer as the property exchanged. However, this rule shall... in part in the hands of the taxpayer for determining gain or loss from a sale or exchange as it would...

  8. Phone use and crashes while driving: A representative survey of drivers in two Australian states.

    PubMed

    McEvoy, Suzanne P; Stevenson, Mark R; Woodward, Mark

    To explore the use and effects of using mobile phones while driving. Cross-sectional survey. New South Wales and Western Australia, 20 October to 7 November 2003. 1347 licensed drivers aged 18 to 65 years. Data were weighted to reflect the corresponding driving population in each state. Mobile phone use while driving (hand-held, hands-free and text messaging); adverse effects of use. While driving, an estimated 57.3% +/- 1.5% of drivers have ever used a mobile phone and 12.4% +/- 1.0% have written text messages. Men, younger drivers and metropolitan residents were more likely to use a phone while driving and to report a higher frequency of use. Enforcement of hand-held phone restrictions was perceived to be low (69.0% +/- 1.5%) and an estimated 39.4% +/- 2.1% of people who phone while driving use a hand-held phone. Half of all drivers (50.1% +/- 1.6%) did not agree with extending the ban to include hands-free phones. Among drivers aged 18-65 years in NSW and WA, an estimated 45 800 +/- 16 466 (0.9% +/- 0.3%) have ever had a crash while using a mobile phone and, in the past year, 146 762 +/- 26 856 (3.0% +/- 0.6%) have had to take evasive action to avoid a crash because of their phone use. Phone use while driving is prevalent and can result in adverse consequences, including crashes. Despite legislation, a significant proportion of drivers continue to use hand-held mobile phones while driving. Enhanced enforcement is needed.

  9. System design of a hand-held mobile robot for craniotomy.

    PubMed

    Kane, Gavin; Eggers, Georg; Boesecke, Robert; Raczkowsky, Jörg; Wörn, Heinz; Marmulla, Rüdiger; Mühling, Joachim

    2009-01-01

    This contribution reports the development and initial testing of a Mobile Robot System for Surgical Craniotomy, the Craniostar. A kinematic system based on a unicycle robot is analysed to provide local positioning through two spiked wheels gripping directly onto a patients skull. A control system based on a shared control system between both the Surgeon and Robot is employed in a hand-held design that is tested initially on plastic phantom and swine skulls. Results indicate that the system has substantially lower risk than present robotically assisted craniotomies, and despite being a hand-held mobile robot, the Craniostar is still capable of sub-millimetre accuracy in tracking along a trajectory and thus achieving an accurate transfer of pre-surgical plan to the operating room procedure, without the large impact of current medical robots based on modified industrial robots.

  10. Inter-Tester Reliability and Precision of Manual Muscle Testing and Hand-Held Dynamometry in Lower Limb Muscles of Children with Spina Bifida

    ERIC Educational Resources Information Center

    Mahony, Kate; Hunt, Adrienne; Daley, Deborah; Sims, Susan; Adams, Roger

    2009-01-01

    Reliability and measurement precision of manual muscle testing (MMT) and hand-held dynamometry (HHD) were compared for children with spina bifida. Strength measures were obtained of the hip flexors, hip abductors, and knee extensors of 20 children (10 males, 10 females; mean age 9 years 10 months; range: 5 to 15 years) by two experienced physical…

  11. Unexploded Ordnance (UXO) Data Analysis System (DAS). Environmental Quality Technology Program

    DTIC Science & Technology

    2009-09-01

    is comprised of an EMI sensor, cesium (Cs) vapor magnetometer , fluxgate magnetometer , hand-held data acquisition computer, integrated power supply...Geometrics model 823A Cs vapor magnetometer . The fluxgate magnetometer is a Bartington model Mag-3MRN60, three- axis fluxgate magnetometer . The system...9. The ERDC hand-held Dual TFM/EMI with ArcSecond positioning system. During standard usage, the fluxgate magnetometer is used to provide the

  12. Intra- and Inter-Rater Reliability of the Rate of Force Development of Hip Abductor Muscles Measured by Hand-Held Dynamometer

    ERIC Educational Resources Information Center

    Takeda, Kazuya; Tanabe, Shigeo; Koyama, Soichiro; Nagai, Tomoko; Sakurai, Hiroaki; Kanada, Yoshikiyo; Shomoto, Koji

    2018-01-01

    The aim of this study was to clarify the intra- and inter-rater reliability of the rate of force development in hip abductor muscle force measurements using a hand-held dynamometer. Thirty healthy adults were separately assessed by two independent raters on two separate days. Rate of force development was calculated from the slope of the…

  13. Portable rapid and quiet drill

    NASA Technical Reports Server (NTRS)

    Badescu, Mireca (Inventor); Chang, Zenshea (Inventor); Sherrit, Stewart (Inventor); Bar-Cohen, Yoseph (Inventor); Bao, Xiaoqi (Inventor)

    2010-01-01

    A hand-held drilling device, and method for drilling using the device, has a housing, a transducer within the housing, with the transducer effectively operating at ultrasonic frequencies, a rotating motor component within the housing and rigid cutting end-effector rotationally connected to the rotating motor component and vibrationally connected to the transducer. The hand-held drilling device of the present invention operates at a noise level of from about 50 decibels or less.

  14. Hand-held optical imager (Gen-2): improved instrumentation and target detectability

    PubMed Central

    Gonzalez, Jean; DeCerce, Joseph; Erickson, Sarah J.; Martinez, Sergio L.; Nunez, Annie; Roman, Manuela; Traub, Barbara; Flores, Cecilia A.; Roberts, Seigbeh M.; Hernandez, Estrella; Aguirre, Wenceslao; Kiszonas, Richard

    2012-01-01

    Abstract. Hand-held optical imagers are developed by various researchers towards reflectance-based spectroscopic imaging of breast cancer. Recently, a Gen-1 handheld optical imager was developed with capabilities to perform two-dimensional (2-D) spectroscopic as well as three-dimensional (3-D) tomographic imaging studies. However, the imager was bulky with poor surface contact (∼30%) along curved tissues, and limited sensitivity to detect targets consistently. Herein, a Gen-2 hand-held optical imager that overcame the above limitations of the Gen-1 imager has been developed and the instrumentation described. The Gen-2 hand-held imager is less bulky, portable, and has improved surface contact (∼86%) on curved tissues. Additionally, the forked probe head design is capable of simultaneous bilateral reflectance imaging of both breast tissues, and also transillumination imaging of a single breast tissue. Experimental studies were performed on tissue phantoms to demonstrate the improved sensitivity in detecting targets using the Gen-2 imager. The improved instrumentation of the Gen-2 imager allowed detection of targets independent of their location with respect to the illumination points, unlike in Gen-1 imager. The developed imager has potential for future clinical breast imaging with enhanced sensitivity, via both reflectance and transillumination imaging. PMID:23224163

  15. Analysis of shipboard aerosol optical thickness measurements from multiple sunphotometers aboard the R/V Ronald H. Brown during the Aerosol Characterization Experiment - Asia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Mark A.; Knobelspiesse, Kirk; Frouin, Robert

    2005-06-20

    Marine sunphotometer measurements collected aboard the R/V Ronald H. Brown during the Aerosol Characterization Experiment - Asia (ACE-Asia) are used to evaluate the ability of complementary instrumentation to obtain the best possible estimates of aerosol optical thickness and Angstrom exponent from ships at sea. A wide range of aerosol conditions, including clean maritime conditions and highly polluted coastal environments, were encountered during the ACE-Asia cruise. The results of this study suggest that shipboard hand-held sunphotometers and fast-rotating shadow-band radiometers (FRSRs) yield similar measurements and uncertainties if proper measurement protocols are used and if the instruments are properly calibrated. The automatedmore » FRSR has significantly better temporal resolution (2 min) than the hand-held sunphotometers when standard measurement protocols are used, so it more faithfully represents the variability of the local aerosol structure in polluted regions. Conversely, results suggest that the hand-held sunphotometers may perform better in clean, maritime air masses for unknown reasons. Results also show that the statistical distribution of the Angstrom exponent measurements is different when the distributions from hand-held sunphotometers are compared with those from the FRSR and that the differences may arise from a combination of factors.« less

  16. Comparison of non-invasive tear film stability measurement techniques.

    PubMed

    Wang, Michael Tm; Murphy, Paul J; Blades, Kenneth J; Craig, Jennifer P

    2018-01-01

    Measurement of tear film stability is commonly used to give an indication of tear film quality but a number of non-invasive techniques exists within the clinical setting. This study sought to compare three non-invasive tear film stability measurement techniques: instrument-mounted wide-field white light clinical interferometry, instrument-mounted keratoscopy and hand-held keratoscopy. Twenty-two subjects were recruited in a prospective, randomised, masked, cross-over study. Tear film break-up or thinning time was measured non-invasively by independent experienced examiners, with each of the three devices, in a randomised order, within an hour. Significant correlation was observed between instrument-mounted interferometric and keratoscopic measurements (p < 0.001) but not between the hand-held device and the instrument-mounted techniques (all p > 0.05). Tear film stability values obtained from the hand-held device were significantly shorter and demonstrated narrower spread than the other two instruments (all p < 0.05), while no significant differences were observed between the two instrument-mounted devices (all p > 0.05). Good clinical agreement exists between the instrument-mounted interferometric and keratoscopic measurements but not between the hand-held device and either of the instrument-mounted techniques. The results highlight the importance of specifying the instrument employed to record non-invasive tear film stability. © 2017 Optometry Australia.

  17. Motion-compensated hand-held common-path Fourier-domain optical coherence tomography probe for image-guided intervention

    NASA Astrophysics Data System (ADS)

    Huang, Yong; Song, Cheol; Liu, Xuan; Kang, Jin U.

    2013-03-01

    A motion-compensated hand-held common-path Fourier-domain optical coherence tomography imaging probe has been developed for image guided intervention during microsurgery. A hand-held prototype instrument was designed and fabricated by integrating an imaging fiber probe inside a stainless steel needle which is attached to the ceramic shaft of a piezoelectric motor housed in an aluminum handle. The fiber probe obtains A-scan images. The distance information was extracted from the A-scans to track the sample surface distance and a fixed distance was maintained by a feedback motor control which effectively compensated hand tremor and target movements in the axial direction. Graphical user interface, real-time data processing, and visualization based on a CPU-GPU hybrid programming architecture were developed and used in the implantation of this system. To validate the system, free-hand optical coherence tomography images using various samples were obtained. The system can be easily integrated into microsurgical tools and robotics for a wide range of clinical applications. Such tools could offer physicians the freedom to easily image sites of interest with reduced risk and higher image quality.

  18. 7 CFR 201.39 - General procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... hand into the bulk and withdrawing representative portions. The hand is inserted in an open position and the fingers are held closely together while the hand is being inserted and the portion withdrawn... bag, the handfuls shall be taken from well-separated points. (b) For free-flowing seed in bags or bulk...

  19. 7 CFR 201.39 - General procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... hand into the bulk and withdrawing representative portions. The hand is inserted in an open position and the fingers are held closely together while the hand is being inserted and the portion withdrawn... bag, the handfuls shall be taken from well-separated points. (b) For free-flowing seed in bags or bulk...

  20. Beyond Textbook Illustrations: Hand-Held Models of Ordered DNA and Protein Structures as 3D Supplements to Enhance Student Learning of Helical Biopolymers

    ERIC Educational Resources Information Center

    Jittivadhna, Karnyupha; Ruenwongsa, Pintip; Panijpan, Bhinyo

    2010-01-01

    Textbook illustrations of 3D biopolymers on printed paper, regardless of how detailed and colorful, suffer from its two-dimensionality. For beginners, computer screen display of skeletal models of biopolymers and their animation usually does not provide the at-a-glance 3D perception and details, which can be done by good hand-held models. Here, we…

  1. Hand-held analyser based on microchip electrophoresis with contactless conductivity detection for measurement of chemical warfare agent degradation products

    NASA Astrophysics Data System (ADS)

    Duran, Karolina-Petkovic; Zhu, Yonggang; Chen, Chuanpin; Swallow, Anthony; Stewart, Robert; Hoobin, Pam; Leech, Patrick; Ovenden, Simon

    2008-12-01

    This paper reports on the development of a hand-held device for on-site detection of organophosphonate nerve agent degradation products. This field-deployable analyzer relies on efficient microchip electrophoresis separation of alkyl methylphosphonic acids and their sensitive contactless conductivity detection. Miniaturized, low-powered design is coupled with promising analytical performance for separating the breakdown products of chemical warfare agents such as Soman, Sarin and VX . The detector has a detection limit of about 10 μg/mL and has a good linear response in the range 10-300 μg/mL concentration range. Applicability to environmental samples is demonstrated .The new hand-held analyzer offers great promise for converting conventional ion chromatography or capillary electrophoresis sophisticated systems into a portable forensic laboratory for faster, simpler and more reliable on-site screening.

  2. Hand held lasers, a hazard to aircraft: How do we address this?

    NASA Astrophysics Data System (ADS)

    Barat, K.

    2015-10-01

    The availability of hand held lasers, commonly termed "laser pointers" is easy and wide spread, through commercial web sites and brick & mortar stores. The output of these hand held devices ranges from 1-5 milliWatts (mW) the legal laser pointer output limit, to 5000mW (5Watts). This is thousand times the maximum limit for pointers. Sadly the abuse of these devices is also wide spread. Over the last few years over 3000 aircraft are exposed to laser hits per year. While these aircraft exposures are of no danger to the aircraft frame but they can cause pilot distractions with the potential to cause a serve accident. The presentation will discuss the problem review visual effects, the regulatory response and how educators need to be aware of the problem and can take steps to educate students in the hope of having an effect.

  3. Do hand-held calorimeters provide reliable and accurate estimates of resting metabolic rate?

    PubMed

    Van Loan, Marta D

    2007-12-01

    This paper provides an overview of a new technique for indirect calorimetry and the assessment of resting metabolic rate. Information from the research literature includes findings on the reliability and validity of a new hand-held indirect calorimeter as well as use in clinical and field settings. Research findings to date are of mixed results. The MedGem instrument has provided more consistent results when compared to the Douglas bag method of measuring metabolic rate. The BodyGem instrument has been shown to be less accurate when compared to standard metabolic carts. Furthermore, when the Body Gem has been used with clinical patients or with under nourished individuals the results have not been acceptable. Overall, there is not a large enough body of evidence to definitively support the use of these hand-held devices for assessment of metabolic rate in a wide variety of clinical or research environments.

  4. Diolistic labeling of neuronal cultures and intact tissue using a hand-held gene gun

    PubMed Central

    O'Brien, John A; Lummis, Sarah CR

    2009-01-01

    Diolistic labeling is a highly efficient method for introducing dyes into cells using biolistic techniques. The use of lipophilic carbocyanine dyes, combined with particle-mediated biolistic delivery using a hand-held gene gun, allows non-toxic labeling of multiple cells in both living and fixed tissue. The technique is rapid (labeled cells can be visualized in minutes) and technically undemanding. Here, we provide a detailed protocol for diolistic labeling of cultured human embryonic kidney 293 cells and whole brain using a hand-held gene gun. There are four major steps: (i) coating gold microcarriers with one or more dyes; (ii) transferring the microcarriers into a cartridge to make a bullet; (iii) preparation of cells or intact tissue; and (iv) firing the microcarriers into cells or tissue. The method can be readily adapted to other cell types and tissues. This protocol can be completed in less than 1 h. PMID:17406443

  5. Hand-Held Volatilome Analyzer Based on Elastically Deformable Nanofibers.

    PubMed

    Yucel, Muge; Akin, Osman; Cayoren, Mehmet; Akduman, Ibrahim; Palaniappan, Alagappan; Liedberg, Bo; Hizal, Gurkan; Inci, Fatih; Yildiz, Umit Hakan

    2018-04-17

    This study reports on a hand-held volatilome analyzer for selective determination of clinically relevant biomarkers in exhaled breath. The sensing platform is based on electrospun polymer nanofiber-multiwalled carbon nanotube (MWCNT) sensing microchannels. Polymer nanofibers of poly(vinylidene fluoride) (PVDF), polystyrene (PS), and poly(methyl methacrylate) (PMMA) incorporated with MWCNT exhibits a stable response to interferences of humidity and CO 2 and provides selective deformations upon exposure of exhaled breath target volatilomes acetone and toluene, exhibiting correlation to diabetes and lung cancer, respectively. The sensing microchannels "P1" (PVDF-MWCNT), "P2" (PS-MWCNT), and "P3" (PMMA-MWCNT) are integrated with a microfluidic cartridge (μ-card) that facilitates collection and concentration of exhaled breath. The volatilome analyzer consists of a conductivity monitoring unit, signal conditioning circuitries and a low energy display module. A combinatorial operation algorithm was developed for analyzing normalized resistivity changes of the sensing microchannels upon exposure to breath in the concentration ranges between 35 ppb and 3.0 ppm for acetone and 1 ppb and 10 ppm for toluene. Subsequently, responses of volatilomes from individuals in the different risk groups of diabetes were evaluated for validation of the proposed methodology. We foresee that proposed methodology provides an avenue for rapid detection of volatilomes thereby enabling point of care diagnosis in high-risk group individuals.

  6. Tactical visualization module

    NASA Astrophysics Data System (ADS)

    Kachejian, Kerry C.; Vujcic, Doug

    1999-07-01

    The Tactical Visualization Module (TVM) research effort will develop and demonstrate a portable, tactical information system to enhance the situational awareness of individual warfighters and small military units by providing real-time access to manned and unmanned aircraft, tactically mobile robots, and unattended sensors. TVM consists of a family of portable and hand-held devices being advanced into a next- generation, embedded capability. It enables warfighters to visualize the tactical situation by providing real-time video, imagery, maps, floor plans, and 'fly-through' video on demand. When combined with unattended ground sensors, such as Combat- Q, TVM permits warfighters to validate and verify tactical targets. The use of TVM results in faster target engagement times, increased survivability, and reduction of the potential for fratricide. TVM technology can support both mounted and dismounted tactical forces involved in land, sea, and air warfighting operations. As a PCMCIA card, TVM can be embedded in portable, hand-held, and wearable PCs. Thus, it leverages emerging tactical displays including flat-panel, head-mounted displays. The end result of the program will be the demonstration of the system with U.S. Army and USMC personnel in an operational environment. Raytheon Systems Company, the U.S. Army Soldier Systems Command -- Natick RDE Center (SSCOM- NRDEC) and the Defense Advanced Research Projects Agency (DARPA) are partners in developing and demonstrating the TVM technology.

  7. Two-gun suicide by simultaneous shots to the head: interdisciplinary reconstruction on the basis of scene investigation, autopsy findings, GSR analysis and examination of firearms, bullets and cartridge cases.

    PubMed

    Grosse Perdekamp, Markus; Nadjem, Hadi; Merkel, Joachim; Braunwarth, Roland; Pollak, Stefan; Thierauf, Annette

    2011-07-01

    Suicidal shots fired simultaneously to the head from two handguns are rare. The authors report about a recent case in which a Smith & Wesson cal. 9 mm pistol and a Smith & Wesson cal. .357 Magnum revolver were used. Sitting on a sofa, a 33-year-old man (member of a shooting club) fired two simultaneous shots to the head; the pistol held in the left hand was discharged into the left temple, and the revolver held in the right hand was fired into the mouth. Both weapons remained in the respective hands. An upside-down muzzle imprint in the left temporal region and recoil injuries of a mandibular incisor, and the lower lip indicated that both the pistol and the revolver had been held in an inverted manner at the time of discharge. Blood stains (backspatter) and gunshot residues were present on both firing hands, whereas forward spatter originating from the exit wounds was deposited on the wall behind the suicide's head.

  8. KSC-04pd0489

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - Florida Gov. Jeb Bush (left) and Center Director Jim Kennedy attend the luncheon at the 2004 Florida Regional FIRST competition held at the University of Central Florida. Both are featured speakers. The event hosted 41 teams from Canada, Brazil, Great Britain and the United States. FIRST is a nonprofit organization, For Inspiration and Recognition of Science and Technology, that sponsors the event pitting gladiator robots against each other in an athletic-style competition. The FIRST robotics competition is designed to provide students with a hands-on, inside look at engineering and other professional careers, pairing high school students with engineer mentors and corporations.

  9. Optical Profilometers Using Adaptive Signal Processing

    NASA Technical Reports Server (NTRS)

    Hall, Gregory A.; Youngquist, Robert; Mikhael, Wasfy

    2006-01-01

    A method of adaptive signal processing has been proposed as the basis of a new generation of interferometric optical profilometers for measuring surfaces. The proposed profilometers would be portable, hand-held units. Sizes could be thus reduced because the adaptive-signal-processing method would make it possible to substitute lower-power coherent light sources (e.g., laser diodes) for white light sources and would eliminate the need for most of the optical components of current white-light profilometers. The adaptive-signal-processing method would make it possible to attain scanning ranges of the order of decimeters in the proposed profilometers.

  10. DC attenuation meter

    DOEpatents

    Hargrove, Douglas L.

    2004-09-14

    A portable, hand-held meter used to measure direct current (DC) attenuation in low impedance electrical signal cables and signal attenuators. A DC voltage is applied to the signal input of the cable and feedback to the control circuit through the signal cable and attenuators. The control circuit adjusts the applied voltage to the cable until the feedback voltage equals the reference voltage. The "units" of applied voltage required at the cable input is the system attenuation value of the cable and attenuators, which makes this meter unique. The meter may be used to calibrate data signal cables, attenuators, and cable-attenuator assemblies.

  11. Reliability of a novel thermal imaging system for temperature assessment of healthy feet.

    PubMed

    Petrova, N L; Whittam, A; MacDonald, A; Ainarkar, S; Donaldson, A N; Bevans, J; Allen, J; Plassmann, P; Kluwe, B; Ring, F; Rogers, L; Simpson, R; Machin, G; Edmonds, M E

    2018-01-01

    Thermal imaging is a useful modality for identifying preulcerative lesions ("hot spots") in diabetic foot patients. Despite its recognised potential, at present, there is no readily available instrument for routine podiatric assessment of patients at risk. To address this need, a novel thermal imaging system was recently developed. This paper reports the reliability of this device for temperature assessment of healthy feet. Plantar skin foot temperatures were measured with the novel thermal imaging device (Diabetic Foot Ulcer Prevention System (DFUPS), constructed by Photometrix Imaging Ltd) and also with a hand-held infrared spot thermometer (Thermofocus® 01500A3, Tecnimed, Italy) after 20 min of barefoot resting with legs supported and extended in 105 subjects (52 males and 53 females; age range 18 to 69 years) as part of a multicentre clinical trial. The temperature differences between the right and left foot at five regions of interest (ROIs), including 1st and 4th toes, 1st, 3rd and 5th metatarsal heads were calculated. The intra-instrument agreement (three repeated measures) and the inter-instrument agreement (hand-held thermometer and thermal imaging device) were quantified using intra-class correlation coefficients (ICCs) and the 95% confidence intervals (CI). Both devices showed almost perfect agreement in replication by instrument. The intra-instrument ICCs for the thermal imaging device at all five ROIs ranged from 0.95 to 0.97 and the intra-instrument ICCs for the hand-held-thermometer ranged from 0.94 to 0.97. There was substantial to perfect inter-instrument agreement between the hand-held thermometer and the thermal imaging device and the ICCs at all five ROIs ranged between 0.94 and 0.97. This study reports the performance of a novel thermal imaging device in the assessment of foot temperatures in healthy volunteers in comparison with a hand-held infrared thermometer. The newly developed thermal imaging device showed very good agreement in repeated temperature assessments at defined ROIs as well as substantial to perfect agreement in temperature assessment with the hand-held infrared thermometer. In addition to the reported non-inferior performance in temperature assessment, the thermal imaging device holds the potential to provide an instantaneous thermal image of all sites of the feet (plantar, dorsal, lateral and medial views). Diabetic Foot Ulcer Prevention System NCT02317835, registered December 10, 2014.

  12. Intrinsic fluorescence based in-vivo detection of cervical precancer with hand held prototype device

    NASA Astrophysics Data System (ADS)

    Meena, Bharat Lal; Raikwar, Akanksha; Pandey, Kiran; Agarwal, Asha; Pantola, Chayanika; Pradhan, Asima

    2018-02-01

    A prototype device (hand held probe) designed and fabricated in the lab has been tested for cervical precancer detection using intrinsic fluorescence. The intrinsic fluorescence gets strongly modulated by the interplay of scattering and absorption. This masks valuable biochemical information which is present in the intrinsic fluorescence. These distortion effects can be minimized by normalizing the polarized fluorescence spectra by the polarized elastic scattering spectra. The measurements have been made with a in-house fabricated device using a 405 nm diode laser and white light source respectively. 166 sites of different grades of cervical pre-cancer biopsy samples (CIN I and CIN II) (CIN: cervical intraepithelial neoplastic) have been discriminated from 29 sites of normal biopsy samples using principal component analysis (PCA) based linear discriminant analysis (LDA). The sensitivity and specificity for discrimination of normal samples from CIN I are found to be 99% and 96% respectively. Further the normal samples can be discriminated from CIN II samples with 96% sensitivity and 96% specificity. Based on these promising ex-vivo results an in-vivo study on patients has been initiated in the hospital. The hand held device built in-house shows promise as a useful tool for in vivo cervical precancer detection by polarized fluorescence. Preliminary in-vivo results on 10 patients indicate the efficacy of the hand held device for screening cervical precancers using intrinsic fluorescence.

  13. Hands-on Science. Exploring Magnification.

    ERIC Educational Resources Information Center

    Kepler, Lynne

    1993-01-01

    Presents hands-on science activities using inexpensive, hand-held microscopes and slides made from simple, readily available materials. The article describes how to introduce students to microscopes and presents directions for using the microscopes and making slides. A student page investigates fingerprints with microscopes. (SM)

  14. Automation Study for Longhorn Army Ammunition Plant Hand Held Signal Flight Assembly, Rocket Barrel Assembly, 40 MM Signal, Final Packaging/Pack-Out, and Star Finishing

    DTIC Science & Technology

    1990-03-01

    J.B. Webb Jonesboro , AR Farmington, MI Crimping Press Joraco Drake Corp. Smithfield, RI Phoenix, AZ Die Cutter Roll Cut Peerless Machinery Co. Harbour...be taken are detailed for each assembly procedure. The report provides overall system integration requirements. The layouts of the two manufacturing...buildings are detailed. Several component changes to the Hand Held Signals are proposed. None of these will affect the operation of the-final product

  15. Results of Skylab experiment T00-2, manual navigation sightings

    NASA Technical Reports Server (NTRS)

    Randle, R. J.

    1976-01-01

    An analysis of navigation data collected using a hand-held space sextant on the second and third manned Skylab missions was presented. From performance data and astronaut comments it was determined that: (1) the space sextant, the sighting station, and the sighting techniques require modification; (2) the sighting window must be of good optical quality; (3) astronaut performance was stable over long mission time; and (4) sightings made with a hand-held sextant were accurate and precise enough for reliable interplanetary manual navigation.

  16. Design and development of equipment for laser wire stripping

    NASA Technical Reports Server (NTRS)

    Iceland, W. F.

    1977-01-01

    Three laser wire strippers have been built for the stripping of Kapton-insulated wire, the baseline wire of the space shuttle orbiter. The strippers are: (1) a bench-model stripper powered with a cw CO2 10.6-micron laser, (2) a hand-held stripper powered with a cw 1.06-micron Nd-YAG laser with an output of 5-7 watts, and (3) a hand-held stripper with a five-inch-long CO2 laser inside the stripping head.

  17. Portable Biomarker Detection with Magnetic Nanotags

    PubMed Central

    Hall, Drew A.; Wang, Shan X.; Murmann, Boris; Gaster, Richard S.

    2012-01-01

    This paper presents a hand-held, portable biosensor platform for quantitative biomarker measurement. By combining magnetic nanoparticle (MNP) tags with giant magnetoresistive (GMR) spin-valve sensors, the hand-held platform achieves highly sensitive (picomolar) and specific biomarker detection in less than 20 minutes. The rapid analysis and potential low cost make this technology ideal for point-of-care (POC) diagnostics. Furthermore, this platform is able to detect multiple biomarkers simultaneously in a single assay, creating a promising diagnostic tool for a vast number of applications. PMID:22495252

  18. Demonstration of the B4C/NaIO4/PTFE Delay in the U.S. Army Hand-Held Signal

    DTIC Science & Technology

    2015-05-20

    Figure 1. Partial cross section diagram of a hand-held signal showing the rocket motor , delay element, expelling charge, and pyrotechnic payload as...The black powder-based rocket motor , consisting of propellant pellets (G) encased in a cardboard tube, contains an axial core hole to accommodate the...that ignites the rocket motor . Simultaneously, the delay element is ignited and burns for an interval (preferably 5−6 s) before it ignites the black

  19. EXTRAVEHICULAR ACTIVITY (EVA) - ASTRONAUT EDWARD H. WHITE II - MISC. - OUTER SPACE

    NASA Image and Video Library

    1965-06-03

    S65-32924 (3 June 1965) --- Astronaut Edward H. White II, pilot of the Gemini IV four-day Earth-orbital mission, floats in the zero gravity of space outside the Gemini IV spacecraft. White wears a specially designed spacesuit; and the visor of the helmet is gold plated to protect him against the unfiltered rays of the sun. He wears an emergency oxygen pack, also. He is secured to the spacecraft by a 25-feet umbilical line and a 23-feet tether line, both wrapped in gold tape to form one cord. In his right hand is a Hand-Held Self-Maneuvering Unit (HHSMU) with which he controls his movements in space. Astronaut James A. McDivitt, command pilot of the mission, remained inside the spacecraft. (This image is black and white) Photo credit: NASA EDITOR'S NOTE: Astronaut White died in the Apollo/Saturn 204 fire at Cape Kennedy on Jan. 27, 1967.

  20. Gemini IV Mission Image - EVA over Texas coast

    NASA Image and Video Library

    1965-06-03

    View of Astronaut Edward H. White II, pilot for the Gemini-Titan 4 space flight, as he floats in zero gravity of space. The extravehicular activity was performed during the third revolution of the Gemini 4 spacecraft. White is attached to the spacecraft by a 25-ft. umbilical line and a 23-ft. tether line,both wrapped in gold tape to form one cord. In his right hand White carries a Hand-Held Self-Maneuvering Unit (HHSMU). The visor of his helmet is gold plated to protect him from the unfiltered rays of the sun. Photo was taken on June 3,1965. G.E.T. time was 4:45 / GMT time was 20:00. Original magazine number was GEM04-16-34642, taken with a Hasselblad camera and a 70mm lens. Film type was Kodak Ektachrome MS (S.O. -217). The original photo was a color negative. It's image number is S65-34642.

  1. EXTRAVEHICULAR ACTIVITY (EVA) - ASTRONAUT EDWARD H. WHITE II - MISC. - OUTER SPACE

    NASA Image and Video Library

    1965-06-03

    S65-32928 (3 June 1965) --- Astronaut Edward H. White II, pilot of the Gemini IV four-day Earth-orbital mission, floats in the zero gravity of space outside the Gemini IV spacecraft. White wears a specially designed spacesuit; and the visor of the helmet is gold plated to protect him against the unfiltered rays of the sun. He wears an emergency oxygen pack, also. He is secured to the spacecraft by a 25-feet umbilical line and a 23-feet tether line, both wrapped in gold tape to form one cord. In his left hand is a Hand-Held Self-Maneuvering Unit (HHSMU) with which he controls his movements in space. Astronaut James A. McDivitt, command pilot of the mission, remained inside the spacecraft. (This image is black and white) Photo credit: NASA EDITOR'S NOTE: Astronaut White died in the Apollo/Saturn 204 fire at Cape Kennedy on Jan. 27, 1967.

  2. Astronaut Ed White - Gemini-4 Extravehicular Activity (EVA)

    NASA Image and Video Library

    1965-01-01

    S65-30432 (3 June 1965) --- Astronaut Edward H. White II, pilot of the Gemini IV four-day Earth-orbital mission, floats in the zero gravity of space outside the Gemini IV spacecraft. White wears a specially designed spacesuit; and the visor of the helmet is gold plated to protect him against the unfiltered rays of the sun. He wears an emergency oxygen pack, also. He is secured to the spacecraft by a 25-feet umbilical line and a 23-feet tether line, both wrapped in gold tape to form one cord. In his right hand is a Hand-Held Self-Maneuvering Unit (HHSMU) with which he controls his movements in space. Astronaut James A. McDivitt, command pilot of the mission, remained inside the spacecraft. EDITOR'S NOTE: Astronaut White died in the Apollo/Saturn 204 fire at Cape Kennedy on Jan. 27, 1967.

  3. ASTRONAUT WHITE, EDWARD - GEMINI-TITAN (GT)-4 - EXTRAVEHICULAR ACTIVITY (EVA)

    NASA Image and Video Library

    1965-01-01

    S65-30433 (3 June 1965) --- Astronaut Edward H. White II, pilot of the Gemini IV four-day Earth-orbital mission, floats in the zero gravity of space outside the Gemini IV spacecraft. White wears a specially designed spacesuit; and the visor of the helmet is gold plated to protect him against the unfiltered rays of the sun. He wears an emergency oxygen pack, also. He is secured to the spacecraft by a 25-feet umbilical line and a 23-feet tether line, both wrapped in gold tape to form one cord. In his right hand is a Hand-Held Self-Maneuvering Unit (HHSMU) with which he controls his movements in space. Astronaut James A. McDivitt, command pilot of the mission, remained inside the spacecraft. Photo credit: NASA EDITOR'S NOTE: Astronaut White died in the Apollo/Saturn 204 fire at Cape Kennedy on Jan. 27, 1967.

  4. Astronaut Edward White - Gemini IV Extravehicular Activity (EVA)

    NASA Image and Video Library

    1965-01-01

    S65-30429 (3 June 1965) --- Astronaut Edward H. White II, pilot of the Gemini IV four-day Earth-orbital mission, floats in the zero gravity of space outside the Gemini IV spacecraft. White wears a specially designed spacesuit; and the visor of the helmet is gold plated to protect him against the unfiltered rays of the sun. He wears an emergency oxygen pack, also. He is secured to the spacecraft by a 25-feet umbilical line and a 23-feet tether line, both wrapped in gold tape to form one cord. In his right hand is a Hand-Held Self-Maneuvering Unit (HHSMU) with which he controls his movements in space. Astronaut James A. McDivitt, command pilot of the mission, remained inside the spacecraft. Photo credit: NASA EDITOR'S NOTE: Astronaut White died in the Apollo/Saturn 204 fire at Cape Kennedy on Jan. 27, 1967.

  5. Magnification concepts: The use of video-probe microscopy to stimulate excitement and hands-on discovery in the science classroom K-12

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henk, C.; Garner, J.; Wandersee, J.H.

    1994-12-31

    We acquired and loaned several durable, easy-to use, though expensive video-probe microscopes. This hand-held, automatically focusing instrument can be used by a five year old and provides instant, excellent, in-focus images up to 200X on a video screen visible to all students simultaneously. The teacher is thus freed from the technical and logistic considerations involved in conventional classroom microscopy. K-12 teachers preview our videotape on probe utilization. They assemble and demonstrate the unit in the presence of our personnel, then check out the probe for use in their own classrooms. Extremely enthusiastic students examine samples ranging from their own fingerprintsmore » and clothing (on TV!) to pond water, prepared microscope slides, and microscope polarizing light phenomena. Teachers report heightened interest in conventional microscope use once the {open_quotes}microscopy connection{close_quotes} has been made.« less

  6. Aeration Zone Symposium

    NASA Astrophysics Data System (ADS)

    Merkel, B.

    The International Symposium on Recent Investigations in the Zone of Aeration (RIZA) was organized by the Institute for Hydrogeology and Hydrochemistry of the Technical University of Munich and held October 1-5, 1984, in the lecture halls of the Grosshadern Klinik in Munich, Federal Republic of Germany (FRG). P. Udluft, B. Merkel, and K.-H. Prüsl, all of the university, were responsible for the organization of the symposium, which was under the patronage of K.-E. Quentin. There were over 200 participants from 22 different countries, among them Australia, Canada, China, India, and the United States. The topics of the symposium were the physical, chemical, and microbiological processes in the unsaturated zone, the region between the surface and the groundwater level. Here a number of complex processes occur that on the one hand are of natural origin and on the other hand are influenced by human activities in a number of ways.

  7. Portable light source unit for simulating fires having an adjustable aperture

    NASA Technical Reports Server (NTRS)

    Youngquist, Robert C. (Inventor); Moerk, John S. (Inventor); Strobel, James P. (Inventor)

    1997-01-01

    A portable, hand held light source unit is employed to check operation of fire detectors, such as hydrogen fire detectors. The unit emits radiation in a narrow band of wavelengths which are generated by the type of fire to be tested, but not by other light sources such as the sun or incandescent lamps. The unit can test fire detectors at different distances, and of different sensitivities. The intensity of the radiation emitted by the unit is adjustable for this purpose by means of a rotatable disk having a plurality of different sized apertures for selective placement between the light source and an output lens. The disk can also be rotated to a calibration position which causes a microprocessor circuit in the unit to initiate a calibration procedure. During this procedure, the lamp intensity is measured by a photodetector contained within the unit, and the microprocessor adjusts the lamp current to insure that its intensity remains within a preset range of values. A green and a red LED are mounted on the unit which indicate to an operator whether the calibration is successful, as well as the condition of the unit's battery power supply.

  8. 29 CFR 1910.242 - Hand and portable powered tools and equipment, general.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. ... 29 Labor 5 2011-07-01 2011-07-01 false Hand and portable powered tools and equipment, general... Powered Tools and Other Hand-Held Equipment § 1910.242 Hand and portable powered tools and equipment...

  9. 29 CFR 1910.242 - Hand and portable powered tools and equipment, general.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. ... 29 Labor 5 2010-07-01 2010-07-01 false Hand and portable powered tools and equipment, general... Powered Tools and Other Hand-Held Equipment § 1910.242 Hand and portable powered tools and equipment...

  10. Evaluation of a hand-held blood gas analyzer for rapid determination of blood gases, electrolytes and metabolites in intensive care setting.

    PubMed

    Luukkonen, Antti A M; Lehto, Tiina M; Hedberg, Pirjo S M; Vaskivuo, Tommy E

    2016-04-01

    Intensive care units, operating rooms, emergency departments, and neonatology units need rapid measurements of blood gases, electrolytes, and metabolites. These analyses can be performed in a central laboratory or at the clinic with traditional or compact cassette-type blood gas analyzers such as the epoc blood gas testing system for analyzing whole blood samples at the bedside. In this study, the performance and interchangeability of a hand-held epoc blood gas analyzer was evaluated. The analytical performance of the epoc analyzer was evaluated by determining within-and between-run precisions. The accuracy of the epoc analyzer was assessed by comparing patient results from the device with those obtained with the Siemens Rapidlab 1265 and Rapidpoint RP500 and Siemens Dimension Vista and Sysmex XE-2100 analyzers. The following parameters were measured: pH, pCO2, pO2, Hb (calc), Na+, K+, iCa2+, glucose, and lactate. The CV% of the epoc's between-day imprecision for the various parameters varied from 0.4 to 8.6. The within-run imprecision CV% varied from 0.6 to 5.2. The squared regression coefficient (R2) between the epoc and RL1265 varied from 0.94 to 0.99, with the exception of Na+ and Ca2+ (R2≥0.82). The correlation (R2) of Na+ and K+ between epoc and Dimension Vista was 0.73 and 0.89, respectively. The correlation (R2) of Hb between the epoc and the XE-2100 analyzer was 0.94. With most of the measured blood gas parameters, the epoc analyzer correlated well with reference techniques. The epoc analyzer is suitable for rapid measurement of the blood gases, the electrolytes, and the metabolites in the ICU.

  11. Smartphone based hand-held quantitative phase microscope using the transport of intensity equation method.

    PubMed

    Meng, Xin; Huang, Huachuan; Yan, Keding; Tian, Xiaolin; Yu, Wei; Cui, Haoyang; Kong, Yan; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2016-12-20

    In order to realize high contrast imaging with portable devices for potential mobile healthcare, we demonstrate a hand-held smartphone based quantitative phase microscope using the transport of intensity equation method. With a cost-effective illumination source and compact microscope system, multi-focal images of samples can be captured by the smartphone's camera via manual focusing. Phase retrieval is performed using a self-developed Android application, which calculates sample phases from multi-plane intensities via solving the Poisson equation. We test the portable microscope using a random phase plate with known phases, and to further demonstrate its performance, a red blood cell smear, a Pap smear and monocot root and broad bean epidermis sections are also successfully imaged. Considering its advantages as an accurate, high-contrast, cost-effective and field-portable device, the smartphone based hand-held quantitative phase microscope is a promising tool which can be adopted in the future in remote healthcare and medical diagnosis.

  12. Hand-held digital books in radiology: convenient access to information.

    PubMed

    D'Alessandro, M P; Galvin, J R; Santer, D M; Erkonen, W E

    1995-02-01

    Radiologists need constant, convenient access to current information throughout the course of their daily work. Today most learning in radiology is obtained from the printed word in books, journals, and teaching files, supplemented by the spoken word in lectures and conferences. Although learning from printed material and lectures has been proved efficacious over time, these media share the disadvantage of not being conveniently available for reference during the course of daily work at the alternator or in the examination room when accurate and up-to-date information is needed the most. As a result, many important questions about patient care go unanswered. We have developed a technique--hand-held digital books--to lower this barrier to searching and retrieval. When radiologists have a digital library that can be carried with them, they will be able to incorporate current radiology information into their daily decision making. We describe a technique for creating hand-held digital books and their future use in radiology.

  13. Combining heterogenous features for 3D hand-held object recognition

    NASA Astrophysics Data System (ADS)

    Lv, Xiong; Wang, Shuang; Li, Xiangyang; Jiang, Shuqiang

    2014-10-01

    Object recognition has wide applications in the area of human-machine interaction and multimedia retrieval. However, due to the problem of visual polysemous and concept polymorphism, it is still a great challenge to obtain reliable recognition result for the 2D images. Recently, with the emergence and easy availability of RGB-D equipment such as Kinect, this challenge could be relieved because the depth channel could bring more information. A very special and important case of object recognition is hand-held object recognition, as hand is a straight and natural way for both human-human interaction and human-machine interaction. In this paper, we study the problem of 3D object recognition by combining heterogenous features with different modalities and extraction techniques. For hand-craft feature, although it reserves the low-level information such as shape and color, it has shown weakness in representing hiconvolutionalgh-level semantic information compared with the automatic learned feature, especially deep feature. Deep feature has shown its great advantages in large scale dataset recognition but is not always robust to rotation or scale variance compared with hand-craft feature. In this paper, we propose a method to combine hand-craft point cloud features and deep learned features in RGB and depth channle. First, hand-held object segmentation is implemented by using depth cues and human skeleton information. Second, we combine the extracted hetegerogenous 3D features in different stages using linear concatenation and multiple kernel learning (MKL). Then a training model is used to recognize 3D handheld objects. Experimental results validate the effectiveness and gerneralization ability of the proposed method.

  14. The healthy heart race: a short-duration, hands-on activity in cardiovascular physiology for museums and science festivals.

    PubMed

    Pressley, Thomas A; Limson, Melvin; Byse, Miranda; Matyas, Marsha Lakes

    2011-09-01

    The "Healthy Heart Race" activity provides a hands-on demonstration of cardiovascular function suitable for lay audiences. It was field tested during the United States of America Science and Engineering Festival held in Washington, DC, in October 2010. The basic equipment for the activity consisted of lengths of plastic tubing, a hand pump, collection containers, clamps, and simulated blood prepared by tinting water with red food coloring. Student participants were first asked to experience the effort required to pump through an unaltered tube. A presenter then applied a strong clamp that pinched each tube downstream from the pump, and students were asked to pump against the increased resistance. The students' observations were then used as the basis for discussions of atherosclerosis and coronary heart disease with the presenters. Distribution of informative postcards during the 2 days of the festival indicated that at least 2,500 students completed the Healthy Heart Race activity. Our experiences to date suggest that the Healthy Heart Race activity can be accomplished effectively in the high-volume, high-distraction environment of a science fair or museum.

  15. A hand-held electronic tongue based on fluorometry for taste assessment of tea.

    PubMed

    Chang, Kuang-Hua; Chen, Richie L C; Hsieh, Bo-Chuan; Chen, Po-Chung; Hsiao, Hsien-Yi; Nieh, Chi-Hua; Cheng, Tzong-Jih

    2010-12-15

    A hand-held electronic tongue was developed for determining taste levels of astringency and umami in tea infusions. The sensing principles are based on quenching the fluorescence of 3-aminophthalate by tannin, and the fluorogenic reaction of o-phthalaldehyde (OPA) with amino acids to determine astringency and umami levels, respectively. Both reactions were measured by a single fluorescence sensing system with same excitation and emission wavelengths (340/425 nm). This work describes in detail the design, fabrication, and performance evaluation of a hand-held fluorometer with an ultra-violet light emitted diode (UVLED) and a photo-detector with a filter built-in. The dimension and the weight of proposed electronic tongue prototype are only 120×60×65 mm(3) and 150 g, respectively. The detection limits of this prototype for theanine and tannic acid were 0.2 μg/ml and 1 μg/ml, respectively. Correlation coefficients of this prototype compared with a commercial fluorescence instrument are both higher than 0.995 in determinations of tannin acid and theanine. Linear detection ranges of the hand-held fluorometer for tannic acid and theanine are 1-20 μg/ml and 0.2-10 μg/ml (CV<5%, n=3), respectively. A specified taste indicator for tea, defined as ratio of umami to astringency, was adopted here to effectively distinguish flavour quality of partially fermented Oolong teas. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Comparative Geometrical Accuracy Investigations of Hand-Held 3d Scanning Systems - AN Update

    NASA Astrophysics Data System (ADS)

    Kersten, T. P.; Lindstaedt, M.; Starosta, D.

    2018-05-01

    Hand-held 3D scanning systems are increasingly available on the market from several system manufacturers. These systems are deployed for 3D recording of objects with different size in diverse applications, such as industrial reverse engineering, and documentation of museum exhibits etc. Typical measurement distances range from 0.5 m to 4.5 m. Although they are often easy-to-use, the geometric performance of these systems, especially the precision and accuracy, are not well known to many users. First geometrical investigations of a variety of diverse hand-held 3D scanning systems were already carried out by the Photogrammetry & Laser Scanning Lab of the HafenCity University Hamburg (HCU Hamburg) in cooperation with two other universities in 2016. To obtain more information about the accuracy behaviour of the latest generation of hand-held 3D scanning systems, HCU Hamburg conducted further comparative geometrical investigations using structured light systems with speckle pattern (Artec Spider, Mantis Vision PocketScan 3D, Mantis Vision F5-SR, Mantis Vision F5-B, and Mantis Vision F6), and photogrammetric systems (Creaform HandySCAN 700 and Shining FreeScan X7). In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data was acquired by measurements with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M). The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  17. Cellular phone use while driving at night.

    PubMed

    Vivoda, Jonathon M; Eby, David W; St Louis, Renée M; Kostyniuk, Lidia P

    2008-03-01

    Use of a cellular phone has been shown to negatively affect one's attention to the driving task, leading to an increase in crash risk. At any given daylight hour, about 6% of US drivers are actively talking on a hand-held cell phone. However, previous surveys have focused only on cell phone use during the day. Driving at night has been shown to be a riskier activity than driving during the day. The purpose of the current study was to assess the rate of hand-held cellular phone use while driving at night, using specialized night vision equipment. In 2006, two statewide direct observation survey waves of nighttime cellular phone use were conducted in Indiana utilizing specialized night vision equipment. Combined results of driver hand-held cellular phone use from both waves are presented in this manuscript. The rates of nighttime cell phone use were similar to results found in previous daytime studies. The overall rate of nighttime hand-held cellular phone use was 5.8 +/- 0.6%. Cellular phone use was highest for females and for younger drivers. In fact, the highest rate observed during the study (of 11.9%) was for 16-to 29-year-old females. The high level of cellular phone use found within the young age group, coupled with the increased crash risk associated with cellular phone use, nighttime driving, and for young drivers in general, suggests that this issue may become an important transportation-related concern.

  18. Bone age maturity assessment using hand-held device

    NASA Astrophysics Data System (ADS)

    Ratib, Osman M.; Gilsanz, Vicente; Liu, Xiaodong; Boechat, M. I.

    2004-04-01

    Purpose: Assessment of bone maturity is traditionally performed through visual comparison of hand and wrist radiograph with existing reference images in textbooks. Our goal was to develop a digital index based on idealized hand Xray images that can be incorporated in a hand held computer and used for visual assessment of bone age for patients. Material and methods: Due to the large variability in bone maturation in normals, we generated a set of "ideal" images obtained by computer combinations of images from our normal reference data sets. Software for hand-held PDA devices was developed for easy navigation through the set of images and visual selection of matching images. A formula based on our statistical analysis provides the standard deviation from normal based on the chronological age of the patient. The accuracy of the program was compared to traditional interpretation by two radiologists in a double blind reading of 200 normal Caucasian children (100 boys, 100 girls). Results: Strong correlations were present between chronological age and bone age (r > 0.9) with no statistical difference between the digital and traditional assessment methods. Determinations of carpal bone maturity in adolescents was slightly more accurate using the digital system. The users did praise the convenience and effectiveness of the digital Palm Index in clinical practice. Conclusion: An idealized digital Palm Bone Age Index provides a convenient and effective alternative to conventional atlases for the assessment of skeletal maturity.

  19. Volumetric Evaluation of Different Obturation Techniques in Primary Teeth Using Spiral Computed Tomography.

    PubMed

    Nagaveni, N B; Yadav, Sneha; Poornima, P; Reddy, Vv Subba; Roshan, N M

    Various obturation techniques have been evaluated for better filling of the root canals in primary teeth using different methods. Spiral Computed Tomography (SCT) is a new revolution in the pediatric endodontics for assessment of quality of the obturation from 3 dimensions. To evaluate the efficiency of 5 different obturation methods in delivering the filling material into the canals of primary teeth using Spiral Computed Tomography scan. A total of 50 canals of primary teeth were prepared, divided into 5 groups with 10 canals in each group and obturated with Zinc Oxide Eugenol cement using 5 different obturation techniques such as Local anesthetic syringe, Tuberculin syringe, Endodontic plugger, hand held Lentulo-spiral, and Lentulo-spiral mounted on slow speed hand piece. The pre and post obturation volume and finally the Percentage of Obturated Volume (POV) were calculated using SCT scan for each group. The data obtained was statistically analyzed using One-way Analysis of Variance (ANOVA) and Tukey's post-hoc test. Lentulo-spiral hand held showed highest POV value followed by Lentulospiral mounted to hand piece, Tuberculin syringe and Endodontic plugger; whereas Anesthetic syringe had least POV (P < 0.05). Lentulo-spiral hand held is the best obturating technique among the 5 groups evaluated as the canals of this group showed maximum percentage of filled material. However, a further study with large sample size is highly essential.

  20. KSC-04pd0501

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - Center Director Jim Kennedy (right, back to camera) talks to members of the KSC-sponsored “Pink” team at the 2004 Florida Regional FIRST competition, held at the University of Central Florida. The annual event is hosting 41 teams from Canada, Brazil, Great Britain and the United States. FIRST is a nonprofit organization, For Inspiration and Recognition of Science and Technology, that sponsors the event pitting robots against each other in an athletic-style competition. The FIRST robotics competition is designed to provide students with a hands-on, inside look at engineering and other professional careers, pairing high school students with engineer mentors and corporations.

  1. Electrical Arc Ignition Testing for Constellation Program

    NASA Technical Reports Server (NTRS)

    Sparks, Kyle; Gallus, Timothy; Smith, Sarah

    2009-01-01

    NASA Johnson Space Center (JSC) Materials and Processes Branch requested that NASA JSC White Sands Test Facility (WSTF) perform testing for the Constellation Program to evaluate the hazard of electrical arc ignition of materials that could be in close proximity to batteries. Specifically, WSTF was requested to perform wire-break electrical arc tests to determine the current threshold for ignition of generic cotton woven fabric samples with a fixed voltage of 3.7 V, a common voltage for hand-held electrical devices. The wire-break test was developed during a previous test program to evaluate the hazard of electrical arc ignition inside the Extravehicular Mobility Unit [1].

  2. KSC-04PD-0499

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. Center Director Jim Kennedy (center) poses for a photo amid the members of the KSC-sponsored Pink team and the FIRST LEGO League at the 2004 Florida Regional FIRST competition, held at the University of Central Florida. The annual event is hosting 41 teams from Canada, Brazil, Great Britain and the United States. FIRST is a nonprofit organization, For Inspiration and Recognition of Science and Technology, that sponsors the event pitting gladiator robots against each other in an athletic-style competition. The FIRST robotics competition is designed to provide students with a hands-on, inside look at engineering and other professional careers, pairing high school students with engineer mentors and corporations.

  3. KSC-04pd0490

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - Florida Gov. Jeb Bush (left) and Center Director Jim Kennedy enjoy a humorous break at the luncheon for the 2004 Florida Regional FIRST competition held at the University of Central Florida. Both are featured speakers. The event hosted 41 teams from Canada, Brazil, Great Britain and the United States. FIRST is a nonprofit organization, For Inspiration and Recognition of Science and Technology, that sponsors the event pitting gladiator robots against each other in an athletic-style competition. The FIRST robotics competition is designed to provide students with a hands-on, inside look at engineering and other professional careers, pairing high school students with engineer mentors and corporations.

  4. KSC-04pd0492

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - Florida Gov. Jeb Bush speaks to attendees at the luncheon held at the 2004 Florida Regional FIRST competition at the University of Central Florida. The event hosted 41 teams from Canada, Brazil, Great Britain and the United States. Center Director Jim Kennedy also spoke at the luncheon. FIRST is a nonprofit organization, For Inspiration and Recognition of Science and Technology, that sponsors the event pitting gladiator robots against each other in an athletic-style competition. The FIRST robotics competition is designed to provide students with a hands-on, inside look at engineering and other professional careers, pairing high school students with engineer mentors and corporations.

  5. KSC-04pd0495

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - Florida Gov. Jeb Bush talks to students competing with their robot at the 2004 Florida Regional FIRST competition, held at the University of Central Florida. Bush and Center Director Jim Kennedy were among observers at the annual event that hosted 41 teams from Canada, Brazil, Great Britain and the United States. FIRST is a nonprofit organization, For Inspiration and Recognition of Science and Technology, that sponsors the event pitting gladiator robots against each other in an athletic-style competition. The FIRST robotics competition is designed to provide students with a hands-on, inside look at engineering and other professional careers, pairing high school students with engineer mentors and corporations.

  6. KSC-04pd0491

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - Florida Gov. Jeb Bush speaks to attendees at the luncheon held at the 2004 Florida Regional FIRST competition at the University of Central Florida. The event hosted 41 teams from Canada, Brazil, Great Britain and the United States. Florida Gov. Jeb Bush also spoke at the luncheon. FIRST is a nonprofit organization, For Inspiration and Recognition of Science and Technology, that sponsors the event pitting gladiator robots against each other in an athletic-style competition. The FIRST robotics competition is designed to provide students with a hands-on, inside look at engineering and other professional careers, pairing high school students with engineer mentors and corporations.

  7. KSC-04pd0504

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - The KSC-sponsored “Pink” team poses for a photo with Florida Gov. Jeb Bush (second from left) during a break at the 2004 Florida Regional FIRST competition, held at the University of Central Florida. The annual event is hosting 41 teams from Canada, Brazil, Great Britain and the United States. FIRST is a nonprofit organization, For Inspiration and Recognition of Science and Technology, that sponsors the event pitting robots against each other in an athletic-style competition. The FIRST robotics competition is designed to provide students with a hands-on, inside look at engineering and other professional careers, pairing high school students with engineer mentors and corporations.

  8. KSC-04pd0488

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - During the luncheon held at the 2004 Florida Regional FIRST competition at the University of Central Florida, Center Director Jim Kennedy praises the teamwork of the students involved. The event hosted 41 teams from Canada, Brazil, Great Britain and the United States. Florida Gov. Jeb Bush also spoke at the luncheon. FIRST is a nonprofit organization, For Inspiration and Recognition of Science and Technology, that sponsors the event pitting gladiator robots against each other in an athletic-style competition. The FIRST robotics competition is designed to provide students with a hands-on, inside look at engineering and other professional careers, pairing high school students with engineer mentors and corporations.

  9. KSC-04PD-0488

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. During the luncheon held at the 2004 Florida Regional FIRST competition at the University of Central Florida, Center Director Jim Kennedy praises the teamwork of the students involved. The event hosted 41 teams from Canada, Brazil, Great Britain and the United States. Florida Gov. Jeb Bush also spoke at the luncheon. FIRST is a nonprofit organization, For Inspiration and Recognition of Science and Technology, that sponsors the event pitting gladiator robots against each other in an athletic-style competition. The FIRST robotics competition is designed to provide students with a hands-on, inside look at engineering and other professional careers, pairing high school students with engineer mentors and corporations.

  10. KSC-04PD-0487

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. During the luncheon held at the 2004 Florida Regional FIRST competition at the University of Central Florida, Center Director Jim Kennedy praises the teamwork of the students involved. The event hosted 41 teams from Canada, Brazil, Great Britain and the United States. Florida Gov. Jeb Bush also spoke at the luncheon. FIRST is a nonprofit organization, For Inspiration and Recognition of Science and Technology, that sponsors the event pitting gladiator robots against each other in an athletic-style competition. The FIRST robotics competition is designed to provide students with a hands-on, inside look at engineering and other professional careers, pairing high school students with engineer mentors and corporations.

  11. Cordless hand-held optical 3D sensor

    NASA Astrophysics Data System (ADS)

    Munkelt, Christoph; Bräuer-Burchardt, Christian; Kühmstedt, Peter; Schmidt, Ingo; Notni, Gunther

    2007-07-01

    A new mobile optical 3D measurement system using phase correlation based fringe projection technique will be presented. The sensor consist of a digital projection unit and two cameras in a stereo arrangement, whereby both are battery powered. The data transfer to a base station will be done via WLAN. This gives the possibility to use the system in complicate, remote measurement situations, which are typical in archaeology and architecture. In the measurement procedure the sensor will be hand-held by the user, illuminating the object with a sequence of less than 10 fringe patterns, within a time below 200 ms. This short sequence duration was achieved by a new approach, which combines the epipolar constraint with robust phase correlation utilizing a pre-calibrated sensor head, containing two cameras and a digital fringe projector. Furthermore, the system can be utilized to acquire the all around shape of objects by using the phasogrammetric approach with virtual land marks introduced by the authors 1, 2. This way no matching procedures or markers are necessary for the registration of multiple views, which makes the system very flexible in accomplishing different measurement tasks. The realized measurement field is approx. 100 mm up to 400 mm in diameter. The mobile character makes the measurement system useful for a wide range of applications in arts, architecture, archaeology and criminology, which will be shown in the paper.

  12. Integrated optical detection of autonomous capillary microfluidic immunoassays:a hand-held point-of-care prototype.

    PubMed

    Novo, P; Chu, V; Conde, J P

    2014-07-15

    The miniaturization of biosensors using microfluidics has potential in enabling the development of point-of-care devices, with the added advantages of reduced time and cost of analysis with limits-of-detection comparable to those obtained through traditional laboratory techniques. Interfacing microfluidic devices with the external world can be difficult especially in aspects involving fluid handling and the need for simple sample insertion that avoids special equipment or trained personnel. In this work we present a point-of-care prototype system by integrating capillary microfluidics with a microfabricated photodiode array and electronic instrumentation into a hand-held unit. The capillary microfluidic device is capable of autonomous and sequential fluid flow, including control of the average fluid velocity at any given point of the analysis. To demonstrate the functionality of the prototype, a model chemiluminescence ELISA was performed. The performance of the integrated optical detection in the point-of-care prototype is equal to that obtained with traditional bench-top instrumentation. The photodiode signals were acquired, displayed and processed by a simple graphical user interface using a computer connected to the microcontroller through USB. The prototype performed integrated chemiluminescence ELISA detection in about 15 min with a limit-of-detection of ≈2 nM with an antibody-antigen affinity constant of ≈2×10(7) M(-1). Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Time motion analysis of nursing work in ICU, telemetry and medical-surgical units.

    PubMed

    Schenk, Elizabeth; Schleyer, Ruth; Jones, Cami R; Fincham, Sarah; Daratha, Kenn B; Monsen, Karen A

    2017-11-01

    This study examined nurses' work, comparing nursing interventions and locations across three units in a United States hospital using Omaha System standardized terminology as the organizing framework. The differences in nurses' acute-care work across unit types are not well understood. Prior investigators have used time-motion methodologies; few have compared differences across units, nor used standardized terminology. Nurse-observers recorded locations and interventions of nurses on three acute-care units using hand-held devices and web-based TimeCaT ™ software. Nursing interventions were mapped to Omaha System terms. Unit-differences were analysed. Nurses changed locations approximately every 2 min, and averaged approximately one intervention/minute. Unit differences were found in both the interventions performed and the locations. Most interventions were case-management related, demonstrating the nurses' patient management/coordination role. Unit differences in nursing interventions and location were found among three unit types. Omaha System terminology, as well as the observational method used, were found to be feasible and practical. Nursing work varies by unit, yet managers have not been armed with empirical data with which to make more informed decisions about nurses' work priorities, clinical outcomes, patient satisfaction, staff satisfaction and cost. The results from this study will help them to do so. © 2017 John Wiley & Sons Ltd.

  14. Hand-held synchronous scan spectrometer for in situ and immediate detection of live/dead bacteria ratio

    NASA Astrophysics Data System (ADS)

    Li, Runze; Goswami, Umang; Walck, Matthew; Khan, Kasfia; Chen, Jie; Cesario, Thomas C.; Rentzepis, Peter M.

    2017-11-01

    The design, construction, and operation of a hand-held synchronously scanned, excitation-emission, double monochromator spectrometer is described. Data show that it is possible to record and display within minutes the fluorescence spectra and ratio of live/dead bacteria in situ. Excitation emission matrix contour plots display clearly bacteria fluorescence spectra before and after UV inactivation, respectively. The separation of the fluorescence band maxima of molecular components, such as tryptophan, tyrosine, and DNA, may be distinguished in the diffused fluorescence spectra of bacteria and mixtures.

  15. Material Analysis and Identification

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KeyMaster Technologies, Inc., develops and markets specialized, hand-held X-ray fluorescence (XRF) instruments and unique tagging technology used to identify and authenticate materials or processes. NASA first met with this Kennewick, Washington-based company as the Agency began seeking companies to develop a hand-held instrument that would detect data matrix symbols on parts covered by paint and other coatings. Since the Federal Aviation Administration was also searching for methods to detect and eliminate the use of unapproved parts, it recommended that NASA and KeyMaster work together to develop a technology that would benefit both agencies.

  16. Balancing fast-rotating parts of hand-held machine drive

    NASA Astrophysics Data System (ADS)

    Korotkov, V. S.; Sicora, E. A.; Nadeina, L. V.; Yongzheng, Wang

    2018-03-01

    The article considers the issues related to the balancing of fast rotating parts of the hand-held machine drive including a wave transmission with intermediate rolling elements, which is constructed on the basis of the single-phase collector motor with a useful power of 1 kW and a nominal rotation frequency of 15000 rpm. The forms of balancers and their location are chosen. The method of balancing is described. The scheme for determining of residual unbalance in two correction planes is presented. Measurement results are given in tables.

  17. Hand-held synchronous scan spectrometer for in situ and immediate detection of live/dead bacteria ratio.

    PubMed

    Li, Runze; Goswami, Umang; Walck, Matthew; Khan, Kasfia; Chen, Jie; Cesario, Thomas C; Rentzepis, Peter M

    2017-11-01

    The design, construction, and operation of a hand-held synchronously scanned, excitation-emission, double monochromator spectrometer is described. Data show that it is possible to record and display within minutes the fluorescence spectra and ratio of live/dead bacteria in situ. Excitation emission matrix contour plots display clearly bacteria fluorescence spectra before and after UV inactivation, respectively. The separation of the fluorescence band maxima of molecular components, such as tryptophan, tyrosine, and DNA, may be distinguished in the diffused fluorescence spectra of bacteria and mixtures.

  18. The GSFC Mark-2 three band hand-held radiometer. [thematic mapper for ground truth data collection

    NASA Technical Reports Server (NTRS)

    Tucker, C. J.; Jones, W. H.; Kley, W. A.; Sundstrom, G. J.

    1980-01-01

    A self-contained, portable, hand-radiometer designed for field usage was constructed and tested. The device, consisting of a hand-held probe containing three sensors and a strap supported electronic module, weighs 4 1/2 kilograms. It is powered by flashlight and transistor radio batteries, utilizes two silicon and one lead sulfide detectors, has three liquid crystal displays, sample and hold radiometric sampling, and its spectral configuration corresponds to LANDSAT-D's thematic mapper bands. The device was designed to support thematic mapper ground-truth data collection efforts and to facilitate 'in situ' ground-based remote sensing studies of natural materials. Prototype instruments were extensively tested under laboratory and field conditions with excellent results.

  19. Reliability of the hand held dynamometer in measuring muscle strength in people with interstitial lung disease.

    PubMed

    Dowman, Leona; McDonald, Christine F; Hill, Catherine J; Lee, Annemarie; Barker, Kathryn; Boote, Claire; Glaspole, Ian; Goh, Nicole; Southcott, Annemarie; Burge, Angela; Ndongo, Rebecca; Martin, Alicia; Holland, Anne E

    2016-09-01

    To evaluate the inter-rater and intra-rater reliability of the hand held dynamometer in measuring muscle strength in people with interstitial lung disease (ILD). Test retest reliability of hand-held dynamometry for elbow flexor and knee extensor strength between two independent raters and two testing sessions. Physiotherapy department within a tertiary hospital. Thirty participants with ILD of varying aetiology were included. Twenty participants completed the inter-rater reliability protocol (10 idiopathic pulmonary fibrosis, mean (SD) age 73 (10) years, 11 male) and 21 participants completed the intra-rater reliability protocol (10 idiopathic pulmonary fibrosis, mean age 71 (10) years, 11 male). Mean muscle strength (kg). Agreement between the two raters and testing sessions was analyzed using Bland-Altman plots and reliability was estimated using intraclass correlation coefficients (ICC). For elbow flexor strength there was a mean difference between raters of -0.6kg (limits of agreement (LOA) -5.6 to 4.4kg) and within raters of -0.3kg (LOA -2.8 to 2.3kg). The ICCs were 0.95 and 0.98, respectively. For knee extensor strength there was a mean difference between raters of -1.5kg (LOA -6.9 to 3.9kg) and within raters of -0.7kg (LOA -3.9 to 2.4kg). The ICCs were 0.95 and 0.97, respectively. Hand-held dynamometry is reliable in measuring elbow flexor and knee extensor strength in people with ILD. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  20. Abdominal aortic aneurysm screening program using hand-held ultrasound in primary healthcare

    PubMed Central

    Kostov, Belchin; Navarro González, Marta; Cararach Salami, Daniel; Pérez Jiménez, Alfonso; Gilabert Solé, Rosa; Bru Saumell, Concepció; Donoso Bach, Lluís; Villalta Martí, Mireia; González-de Paz, Luis; Ruiz Riera, Rafael; Riambau Alonso, Vicenç; Acar-Denizli, Nihan; Farré Almacellas, Marta; Ramos-Casals, Manuel; Benavent Àreu, Jaume

    2017-01-01

    We determined the feasibility of abdominal aortic aneurysm (AAA) screening program led by family physicians in public primary healthcare setting using hand-held ultrasound device. The potential study population was 11,214 men aged ≥ 60 years attended by three urban, public primary healthcare centers. Participants were recruited by randomly-selected telephone calls. Ultrasound examinations were performed by four trained family physicians with a hand-held ultrasound device (Vscan®). AAA observed were verified by confirmatory imaging using standard ultrasound or computed tomography. Cardiovascular risk factors were determined. The prevalence of AAA was computed as the sum of previously-known aneurysms, aneurysms detected by the screening program and model-based estimated undiagnosed aneurysms. We screened 1,010 men, with mean age of 71.3 (SD 6.9) years; 995 (98.5%) men had normal aortas and 15 (1.5%) had AAA on Vscan®. Eleven out of 14 AAA-cases (78.6%) had AAA on confirmatory imaging (one patient died). The total prevalence of AAA was 2.49% (95%CI 2.20 to 2.78). The median aortic diameter at diagnosis was 3.5 cm in screened patients and 4.7 cm (p<0.001) in patients in whom AAA was diagnosed incidentally. Multivariate logistic regression analysis identified coronary heart disease (OR = 4.6, 95%CI 1.3 to 15.9) as the independent factor with the highest odds ratio. A screening program led by trained family physicians using hand-held ultrasound was a feasible, safe and reliable tool for the early detection of AAA. PMID:28453577

  1. Prosthetic Hand Lifts Heavy Loads

    NASA Technical Reports Server (NTRS)

    Carden, James R.; Norton, William; Belcher, Jewell G.; Vest, Thomas W.

    1991-01-01

    Prosthetic hand designed to enable amputee to lift diverse heavy objects like rocks and logs. Has simple serrated end effector with no moving parts. Prosthesis held on forearm by system of flexible straps. Features include ruggedness, simplicity, and relatively low cost.

  2. Hand-transmitted vibration and biodynamic response of the human hand-arm: a critical review.

    PubMed

    Dong, R G; Rakheja, S; Schopper, A W; Han, B; Smutz, W P

    2001-01-01

    Hand-arm vibration syndrome (HAVS) has been associated with prolonged exposure to vibration transmitted to the human hand-arm system from hand-held power tools, vibrating machines, or hand-held vibrating workpieces. The biodynamic response of the human hand and arm to hand transmitted vibration (HTV) forms an essential basis for effective evaluations of exposures, vibration-attenuation mechanisms, and potential injury mechanisms. The biodynamic response to HTV and its relationship to HAVS are critically reviewed and discussed to highlight the advances and the need for further research. In view of its strong dependence on the nature of HTV and the lack of general agreement on the characteristics of HTV, the reported studies are first reviewed to enhance an understanding of HTV and related issues. The characteristics of HTV and relevant unresolved issues are discussed on the basis of measured data, proposed standards, and measurement methods, while the need for further developments in measurement systems is emphasized. The studies on biodynamic response and their findings are grouped into four categories based on the methodology used and the objective. These include studies on (1) through-the-hand-arm response, expressed in terms of vibration transmissibility; (2) to-the-hand response, expressed in terms of the force-motion relationship of the hand-arm system; (3) to-the-hand biodynamic response function, expressed in terms of vibration energy absorption; and (4) computer modeling of the biodynamic response characteristics.

  3. A new hand-held microfluidic cytometer for evaluating irradiation damage by analysis of the damaged cells distribution.

    PubMed

    Wang, Junsheng; Fan, Zhiqiang; Zhao, Yile; Song, Younan; Chu, Hui; Song, Wendong; Song, Yongxin; Pan, Xinxiang; Sun, Yeqing; Li, Dongqing

    2016-03-17

    Space radiation brings uneven damages to cells. The detection of the distribution of cell damage plays a very important role in radiation medicine and the related research. In this paper, a new hand-held microfluidic flow cytometer was developed to evaluate the degree of radiation damage of cells. The device we propose overcomes the shortcomings (e.g., large volume and high cost) of commercial flow cytometers and can evaluate the radiation damage of cells accurately and quickly with potential for onsite applications. The distribution of radiation-damaged cells is analyzed by a simultaneous detection of immunofluorescence intensity of γ-H2AX and resistance pulse sensor (RPS) signal. The γ-H2AX fluorescence intensity provides information of the degree of radiation damage in cells. The ratio of the number of cells with γ-H2AX fluorescence signals to the total numbers of cells detected by RPS indicates the percentage of the cells that are damaged by radiation. The comparison experiment between the developed hand-held microfluidic flow cytometer and a commercial confocal microscope indicates a consistent and comparable detection performance.

  4. A new hand-held microfluidic cytometer for evaluating irradiation damage by analysis of the damaged cells distribution

    NASA Astrophysics Data System (ADS)

    Wang, Junsheng; Fan, Zhiqiang; Zhao, Yile; Song, Younan; Chu, Hui; Song, Wendong; Song, Yongxin; Pan, Xinxiang; Sun, Yeqing; Li, Dongqing

    2016-03-01

    Space radiation brings uneven damages to cells. The detection of the distribution of cell damage plays a very important role in radiation medicine and the related research. In this paper, a new hand-held microfluidic flow cytometer was developed to evaluate the degree of radiation damage of cells. The device we propose overcomes the shortcomings (e.g., large volume and high cost) of commercial flow cytometers and can evaluate the radiation damage of cells accurately and quickly with potential for onsite applications. The distribution of radiation-damaged cells is analyzed by a simultaneous detection of immunofluorescence intensity of γ-H2AX and resistance pulse sensor (RPS) signal. The γ-H2AX fluorescence intensity provides information of the degree of radiation damage in cells. The ratio of the number of cells with γ-H2AX fluorescence signals to the total numbers of cells detected by RPS indicates the percentage of the cells that are damaged by radiation. The comparison experiment between the developed hand-held microfluidic flow cytometer and a commercial confocal microscope indicates a consistent and comparable detection performance.

  5. Summer Enrichment Programs to Foster Interest in STEM Education for Students with Blindness or Low Vision

    ERIC Educational Resources Information Center

    Supalo, Cary A.; Hill, April A.; Larrick, Carleigh G.

    2014-01-01

    Hands-on science enrichment experiences can be limited for students with blindness or low vision (BLV). This manuscript describes recent hands-on summer enrichment programs held for BLV students. Also presented are innovative technologies that were developed to provide spoken quantitative feedback for BLV students engaged in hands-on science…

  6. 78 FR 16329 - Self-Regulatory Organizations; NYSE Arca, Inc.; Notice of Filing and Immediate Effectiveness of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-14

    ... would record orders in a hand written format that in turn could be transmitted to a Floor Broker's EOC... the Exchange. Floor Brokers could hand write order information into the Electronic Tablet upon receipt... and hand held applications. The EOC was developed by the Exchange to fulfill one of the undertakings...

  7. 78 FR 16332 - Self-Regulatory Organizations; NYSE MKT LLC; Notice of Filing and Immediate Effectiveness of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-14

    ... hand written format that in turn could be transmitted to a Floor Broker's EOC workstation for... Brokers could hand write order information into the Electronic Tablet upon receipt of an order, route the... communications interface between booth terminals and the Floor Broker work stations and hand held applications...

  8. Irrigation management with remote sensing. [Navajo Indian Irrigation Project

    NASA Technical Reports Server (NTRS)

    Harlan, C.; Heilman, J. L.; Moore, D.; Myers, V. (Principal Investigator)

    1982-01-01

    Two visible/near IR hand held radiometers and a hand held thermoradiometer were used along with soil moisture and lysimetric measurements in a study of soil moisture distribution in afalfa fields on the Navajo Indian Irrigation Project near farmington, New Mexico. Radiances from irrigated plots were measured and converted to reflectances. Surface soil water contents (o cm to 4 cm) were determined gravimetrically on samples collected at the same time as the spectral measurements. The relationship between the spectral measurements and the crop coefficient were evaluated to demonstrate potential for using spectral measurement to estimate crop coefficient.

  9. Catalog of Space Shuttle Earth Observations Hand-Held Photography: Space Transportation System (STS) 41-6 Mission

    NASA Technical Reports Server (NTRS)

    Nowakowski, Barbara S.; Palmer, Wesley F.

    1985-01-01

    This document catalogs Space Shuttle hand-held Earth observations photography which was collected on the Space Transportation System (STS) 41-G mission of October 1984. The catalog includes the following data for each of 2480 frames: geographical name, feature description, latitude and longitude, percentage of cloud cover, look direction and tilt, lens focal length, exposure evaluation, stereopairs, and orbit number. The catalog is a product of the Space Shuttle Earth Observations Project, Solar System Exploration Division, Space and Life Sciences Directorate, of the National Aeronautics and Space Administration, Lyndon B. Johnson Space Center.

  10. Driver hand-held mobile phone use and safety belt use.

    PubMed

    Eby, David W; Vivoda, Jonathon M

    2003-11-01

    The purposes of the study were to identify hand-held mobile phone use trends for Michigan and to compare safety belt use between users and nonusers. Mobile phone and safety belt use was investigated by a direct observation survey of drivers at intersections in Michigan. Data were weighted to calculate mobile phone use and safety belt use rates statewide. The study showed 2.7% of Michigan drivers were using a mobile phone at any given daylight time. Safety belt use of current mobile phone users was significantly lower than those not using mobile phones.

  11. Development of dual sensor hand-held detector

    NASA Astrophysics Data System (ADS)

    Sezgin, Mehmet

    2010-04-01

    In this paper hand-held dual sensor detector development requirements are considered dedicated to buried object detection. Design characteristics of such a system are categorized and listed. Hardware and software structures, ergonomics, user interface, environmental and EMC/EMI tests to be applied and performance test issues are studied. Main properties of the developed system (SEZER) are presented, which contains Metal Detector (MD) and Ground Penetrating Radar (GPR). The realized system has ergonomic structure and can detect both metallic and non-metallic buried objects. Moreover classification of target is possible if it was defined to the signal processing software in learning phase.

  12. Rapid Diagnosis of an Ulnar Fracture with Portable Hand-Held Ultrasound

    NASA Technical Reports Server (NTRS)

    Kirkpatrick, Andrew W.; Brown, Ross; Diebel, Lawrence N.; Nicolaou, Savvas; Marshburn, Tom; Dulchavsky, Scott A.

    2002-01-01

    Orthopedic fractures are a common injury in operational activities, injuries that often occur in isolated or hostile environments. Clinical ultrasound devices have become more user friendly and lighter allowing them to be easily transported with forward medical teams. The bone-soft tissue interface has a very large acoustic impedance, with a high reflectance that can be used to visualize breaks in contour including fractures. Herein reported is a case of an ulnar fracture that was quickly visualized in the early phase of a multi-system trauma resuscitation with a hand-held ultrasound device. The implications for operational medicine are discussed.

  13. STS-53 Discovery, OV-103, DOD Hercules digital electronic imagery equipment

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-53 Discovery, Orbiter Vehicle (OV) 103, Department of Defense (DOD) mission Hand-held Earth-oriented Real-time Cooperative, User-friendly, Location, targeting, and Environmental System (Hercules) spaceborne experiment equipment is documented in this table top view. HERCULES is a joint NAVY-NASA-ARMY payload designed to provide real-time high resolution digital electronic imagery and geolocation (latitude and longitude determination) of earth surface targets of interest. HERCULES system consists of (from left to right): a specially modified GRID Systems portable computer mounted atop NASA developed Playback-Downlink Unit (PDU) and the Naval Research Laboratory (NRL) developed HERCULES Attitude Processor (HAP); the NASA-developed Electronic Still Camera (ESC) Electronics Box (ESCEB) including removable imagery data storage disks and various connecting cables; the ESC (a NASA modified Nikon F-4 camera) mounted atop the NRL HERCULES Inertial Measurement Unit (HIMU) containing the three

  14. STS-53 Discovery, OV-103, DOD Hercules digital electronic imagery equipment

    NASA Image and Video Library

    1992-04-22

    STS-53 Discovery, Orbiter Vehicle (OV) 103, Department of Defense (DOD) mission Hand-held Earth-oriented Real-time Cooperative, User-friendly, Location, targeting, and Environmental System (Hercules) spaceborne experiment equipment is documented in this table top view. HERCULES is a joint NAVY-NASA-ARMY payload designed to provide real-time high resolution digital electronic imagery and geolocation (latitude and longitude determination) of earth surface targets of interest. HERCULES system consists of (from left to right): a specially modified GRID Systems portable computer mounted atop NASA developed Playback-Downlink Unit (PDU) and the Naval Research Laboratory (NRL) developed HERCULES Attitude Processor (HAP); the NASA-developed Electronic Still Camera (ESC) Electronics Box (ESCEB) including removable imagery data storage disks and various connecting cables; the ESC (a NASA modified Nikon F-4 camera) mounted atop the NRL HERCULES Inertial Measurement Unit (HIMU) containing the three-axis ring-laser gyro.

  15. Coastal mining

    NASA Astrophysics Data System (ADS)

    Bell, Peter M.

    The Exclusive Economic Zone (EEZ) declared by President Reagan in March 1983 has met with a mixed response from those who would benefit from a guaranteed, 200-nautical-mile (370-km) protected underwater mining zone off the coasts of the United States and its possessions. On the one hand, the U.S. Department of the Interior is looking ahead and has been very successful in safeguarding important natural resources that will be needed in the coming decades. On the other hand, the mining industry is faced with a depressed metals and mining market.A report of the Exclusive Economic Zone Symposium held in November 1983 by the U.S. Geological Survey, the Mineral Management Service, and the Bureau of Mines described the mixed response as: “ … The Department of Interior … raring to go into promotion of deep-seal mining but industrial consortia being very pessimistic about the program, at least for the next 30 or so years.” (Chemical & Engineering News, February 5, 1983).

  16. ASTRONAUT WHITE, EDWARD H. II - GEMINI-IV - EXTRAVEHICULAR ACTIVITY (EVA) - CREW TRAINING - MSC

    NASA Image and Video Library

    2009-06-03

    S65-30431 (3 June 1965) --- Astronaut Edward H. White II, pilot of the Gemini IV four-day Earth-orbital mission, floats in the zero gravity of space outside the Gemini IV spacecraft. Behind him is the brilliant blue Earth and its white cloud cover. White wears a specially designed spacesuit; and the visor of the helmet is gold plated to protect him against the unfiltered rays of the sun. He wears an emergency oxygen pack, also. He is secured to the spacecraft by a 25-feet umbilical line and a 23-feet tether line, both wrapped in gold tape to form one cord. In his left hand is a Hand-Held Self-Maneuvering Unit (HHSMU) with which he controls his movements in space. Astronaut James A. McDivitt, command pilot of the mission, remained inside the spacecraft. Photo credit: NASA EDITOR'S NOTE: Astronaut White died in the Apollo/Saturn 204 fire at Cape Kennedy on Jan. 27, 1967.

  17. Performance evaluation of haptic hand-controllers in a robot-assisted surgical system.

    PubMed

    Zareinia, Kourosh; Maddahi, Yaser; Ng, Canaan; Sepehri, Nariman; Sutherland, Garnette R

    2015-12-01

    This paper presents the experimental evaluation of three commercially available haptic hand-controllers to evaluate which was more suitable to the participants. Two surgeons and seven engineers performed two peg-in-hole tasks with different levels of difficulty. Each operator guided the end-effector of a Kuka manipulator that held surgical forceps and was equipped with a surgical microscope. Sigma 7, HD(2) and PHANToM Premium 3.0 hand-controllers were compared. Ten measures were adopted to evaluate operators' performances with respect to effort, speed and accuracy in completing a task, operator improvement during the tests, and the force applied by each haptic device. The best performance was observed with the Premium 3.0; the hand-piece was able to be held in a similar way to that used by surgeons to hold conventional tools. Hand-controllers with a linkage structure similar to the human upper extremity take advantage of the inherent human brain connectome, resulting in improved surgeon performance during robotic-assisted surgery. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Touchfree medical interfaces.

    PubMed

    Rossol, Nathaniel; Cheng, Irene; Rui Shen; Basu, Anup

    2014-01-01

    Real-time control of visual display systems via mid-air hand gestures offers many advantages over traditional interaction modalities. In medicine, for example, it allows a practitioner to adjust display values, e.g. contrast or zoom, on a medical visualization interface without the need to re-sterilize the interface. However, when users are holding a small tool (such as a pen, surgical needle, or computer stylus) the need to constantly put the tool down in order to make hand gesture interactions is not ideal. This work presents a novel interface that automatically adjusts for gesturing with hands and hand-held tools to precisely control medical displays. The novelty of our interface is that it uses a single set of gestures designed to be equally effective for fingers and hand-held tools without using markers. This type of interface was previously not feasible with low-resolution depth sensors such as Kinect, but is now achieved by using the recently released Leap Motion controller. Our interface is validated through a user study on a group of people given the task of adjusting parameters on a medical image.

  19. Ergonomic analysis of fastening vibration based on ISO Standard 5349 (2001).

    PubMed

    Joshi, Akul; Leu, Ming; Murray, Susan

    2012-11-01

    Hand-held power tools used for fastening operations exert high dynamic forces on the operator's hand-arm, potentially causing injuries to the operator in the long run. This paper presents a study that analyzed the vibrations exerted by two hand-held power tools used for fastening operations with the operating exhibiting different postures. The two pneumatic tools, a right-angled nut-runner and an offset pistol-grip, are used to install shearing-type fasteners. A tri-axial accelerometer is used to measure the tool's vibration. The position and orientation of the transducer mounted on the tool follows the ISO-5349 Standard. The measured vibration data is used to compare the two power tools at different operating postures. The data analysis determines the number of years required to reach a 10% probability of developing finger blanching. The results indicate that the pistol-grip tool induces more vibration in the hand-arm than the right-angled nut-runner and that the vibrations exerted on the hand-arm vary for different postures. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  20. A national voice network with satellite and small transceivers

    NASA Technical Reports Server (NTRS)

    Reilly, N. B.; Smith, J. G.

    1978-01-01

    A geostationary satellite utilizing a large multiple-beam UHF antenna is shown to be potentially capable of providing tens of thousands of voice channels for hundreds of thousands of mobile ground terminals using hand-held or vehicular-mounted transceivers with whip antennas. Inclusion of on-board network switching facilities permits full interconnection between any terminal pair within the continental United States (CONUS). Configuration tradeoff studies at selected frequencies from 150 to 1500 MHz, with antenna diameters ranging from 20 to 200 m, and CONUS-coverage multiple beams down to 0.3 deg beamwidth, establish that monthly system user costs in the range of $90 to $150, including leased and maintained ground equipment, are feasible.

  1. Promoting Physical Activity through Hand-Held Computer Technology

    PubMed Central

    King, Abby C.; Ahn, David K.; Oliveira, Brian M.; Atienza, Audie A.; Castro, Cynthia M.; Gardner, Christopher D.

    2009-01-01

    Background Efforts to achieve population-wide increases in walking and similar moderate-intensity physical activities potentially can be enhanced through relevant applications of state-of-the-art interactive communication technologies. Yet few systematic efforts to evaluate the efficacy of hand-held computers and similar devices for enhancing physical activity levels have occurred. The purpose of this first-generation study was to evaluate the efficacy of a hand-held computer (i.e., personal digital assistant [PDA]) for increasing moderate intensity or more vigorous (MOD+) physical activity levels over 8 weeks in mid-life and older adults relative to a standard information control arm. Design Randomized, controlled 8-week experiment. Data were collected in 2005 and analyzed in 2006-2007. Setting/Participants Community-based study of 37 healthy, initially underactive adults aged 50 years and older who were randomized and completed the 8-week study (intervention=19, control=18). Intervention Participants received an instructional session and a PDA programmed to monitor their physical activity levels twice per day and provide daily and weekly individualized feedback, goal setting, and support. Controls received standard, age-appropriate written physical activity educational materials. Main Outcome Measure Physical activity was assessed via the Community Healthy Activities Model Program for Seniors (CHAMPS) questionnaire at baseline and 8 weeks. Results Relative to controls, intervention participants reported significantly greater 8-week mean estimated caloric expenditure levels and minutes per week in MOD+ activity (p<0.04). Satisfaction with the PDA was reasonably high in this largely PDA-naive sample. Conclusions Results from this first-generation study indicate that hand-held computers may be effective tools for increasing initial physical activity levels among underactive adults. PMID:18201644

  2. Assessment of isometric muscle strength and rate of torque development with hand-held dynamometry: Test-retest reliability and relationship with gait velocity after stroke.

    PubMed

    Mentiplay, Benjamin F; Tan, Dawn; Williams, Gavin; Adair, Brooke; Pua, Yong-Hao; Bower, Kelly J; Clark, Ross A

    2018-04-27

    Isometric rate of torque development examines how quickly force can be exerted and may resemble everyday task demands more closely than isometric strength. Rate of torque development may provide further insight into the relationship between muscle function and gait following stroke. Aims of this study were to examine the test-retest reliability of hand-held dynamometry to measure isometric rate of torque development following stroke, to examine associations between strength and rate of torque development, and to compare the relationships of strength and rate of torque development to gait velocity. Sixty-three post-stroke adults participated (60 years, 34 male). Gait velocity was assessed using the fast-paced 10 m walk test. Isometric strength and rate of torque development of seven lower-limb muscle groups were assessed with hand-held dynamometry. Intraclass correlation coefficients were calculated for reliability and Spearman's rho correlations were calculated for associations. Regression analyses using partial F-tests were used to compare strength and rate of torque development in their relationship with gait velocity. Good to excellent reliability was shown for strength and rate of torque development (0.82-0.97). Strong associations were found between strength and rate of torque development (0.71-0.94). Despite high correlations between strength and rate of torque development, rate of torque development failed to provide significant value to regression models that already contained strength. Assessment of isometric rate of torque development with hand-held dynamometry is reliable following stroke, however isometric strength demonstrated greater relationships with gait velocity. Further research should examine the relationship between dynamic measures of muscle strength/torque and gait after stroke. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. The reliability and validity of hand-held refractometry water content measures of hydrogel lenses.

    PubMed

    Nichols, Jason J; Mitchell, G Lynn; Good, Gregory W

    2003-06-01

    To investigate within- and between-examiner reliability and validity of hand-held refractometry water content measures of hydrogel lenses. Nineteen lenses of various nominal water contents were examined by two examiners on two occasions separated by 1 hour. An Atago N2 hand-held refractometer was used for all water content measures. Lenses were presented in a random order to each examiner by a third party, and examiners were masked to any potential lens identifiers. Intraclass correlation coefficients (ICC), 95% limits of agreement, and Wilcoxon signed rank test were used to characterize the within- and between-examiner reliability and validity of lens water content measures. Within-examiner reliability was excellent (ICC, 0.97; 95% limits of agreement, -3.6% to +5.7%), and the inter-visit mean difference of 1.1 +/- 2.4% was not biased (p = 0.08). Between-examiner reliability was also excellent (ICC, 0.98; 95% limits of agreement, -4.1% to +3.9%). The mean difference between examiners was -0.1 +/- 2.1% (p = 0.83). The mean difference between the nominally reported water content and our water content measures was -2.1 +/- 1.7% (p < 0.001); the 95% limits of agreement for this difference were -5.4% to +1.1%. There is good reliability within and between examiners in measuring water content of hydrogel lenses. However, with our sample of lenses, examiners tended to overestimate the nominal water content of hydrogel lenses. As discussed, this bias may be associated with the Brix scale used in refractometry and is material dependent. Therefore, investigators may need to account for bias when measuring hydrogel lens water content via hand-held refractometry.

  4. 33. BENCH CORE STATION, GREY IRON FOUNDRY CORE ROOM WHERE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. BENCH CORE STATION, GREY IRON FOUNDRY CORE ROOM WHERE CORE MOLDS WERE HAND FILLED AND OFTEN PNEUMATICALLY COMPRESSED WITH A HAND-HELD RAMMER BEFORE THEY WERE BAKED. - Stockham Pipe & Fittings Company, Grey Iron Foundry, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  5. Learning "Hands On."

    ERIC Educational Resources Information Center

    Ritter, Janice T.

    2001-01-01

    Discusses a computer teacher's incorporation of hand-held computer technology into her third- and fifth-grade students' study of acid rain. The project successfully brought two grade levels together for cross-grade research, provided an opportunity for classroom teachers and technology specialists to work collaboratively, and enhanced students'…

  6. 46 CFR 160.036-2 - Type.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-2 Type. (a) Handheld rocket-propelled parachute red flare distress signals specified by this subpart... fired from the hand to provide a rocket-propelled parachute red flare distress signal. (b) [Reserved] ...

  7. 46 CFR 160.036-2 - Type.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-2 Type. (a) Handheld rocket-propelled parachute red flare distress signals specified by this subpart... fired from the hand to provide a rocket-propelled parachute red flare distress signal. (b) [Reserved] ...

  8. 46 CFR 160.036-2 - Type.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-2 Type. (a) Handheld rocket-propelled parachute red flare distress signals specified by this subpart... fired from the hand to provide a rocket-propelled parachute red flare distress signal. (b) [Reserved] ...

  9. 46 CFR 160.036-2 - Type.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-2 Type. (a) Handheld rocket-propelled parachute red flare distress signals specified by this subpart... fired from the hand to provide a rocket-propelled parachute red flare distress signal. (b) [Reserved] ...

  10. 46 CFR 160.036-2 - Type.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-2 Type. (a) Handheld rocket-propelled parachute red flare distress signals specified by this subpart... fired from the hand to provide a rocket-propelled parachute red flare distress signal. (b) [Reserved] ...

  11. Changing smoking attitudes by strengthening weak antismoking beliefs - Taiwan as an example.

    PubMed

    Chang, Chingching

    2006-12-01

    I first explored the strength of Taiwanese high school students' beliefs regarding five antismoking messages. Findings of a nationwide survey showed that the students held these beliefs in the following order of decreasing strength: second-hand smoke damages health, smoking has long-term health consequences, smoking has short-term health consequences, cigarette marketers are manipulative, and smokers are perceived negatively. Experiment one further showed that antismoking ads featuring weakly held beliefs are more effective than those featuring strongly held beliefs. Experiment two demonstrated that antismoking campaigns need to be framed carefully; in general, it is more effective to positively frame messages about strongly held antismoking beliefs but negatively frame messages about weakly held antismoking beliefs.

  12. Portable computing for taking part of the lab to the sample types of applications. From hand held personal digital assistants to smart phones for mobile spectrometry

    NASA Astrophysics Data System (ADS)

    Weagant, Scott; Karanassios, Vassili

    2015-06-01

    The use of portable hand held computing devices for the acquisition of spectrochemical data is briefly discussed using examples from the author's laboratory. Several network topologies are evaluated. At present, one topology that involves a portable computing device for data acquisition and spectrometer control and that has wireless access to the internet at one end and communicates with a smart phone at the other end appears to be better suited for "taking part of the lab to the sample" types of applications. Thus, spectrometric data can be accessed from anywhere in the world.

  13. Hand-held optoacoustic probe for three-dimensional imaging of human morphology and function

    NASA Astrophysics Data System (ADS)

    Deán-Ben, X. Luís.; Razansky, Daniel

    2014-03-01

    We report on a hand-held imaging probe for real-time optoacoustic visualization of deep tissues in three dimensions. The proposed solution incorporates a two-dimensional array of ultrasonic sensors densely distributed on a spherical surface, whereas illumination is performed coaxially through a cylindrical cavity in the array. Visualization of three-dimensional tomographic data at a frame rate of 10 images per second is enabled by parallel recording of 256 time-resolved signals for each individual laser pulse along with a highly efficient GPUbased real-time reconstruction. A liquid coupling medium (water), enclosed in a transparent membrane, is used to guarantee transmission of the optoacoustically generated waves to the ultrasonic detectors. Excitation at multiple wavelengths further allows imaging spectrally distinctive tissue chromophores such as oxygenated and deoxygenated haemoglobin. The performance is showcased by video-rate tracking of deep tissue vasculature and three-dimensional measurements of blood oxygenenation in a healthy human volunteer. The flexibility provided by the hand-held hardware design, combined with the real-time operation, makes the developed platform highly usable for both small animal research and clinical imaging in multiple indications, including cancer, inflammation, skin and cardiovascular diseases, diagnostics of lymphatic system and breast

  14. Ultratrace detector for hand-held gas chromatography

    DOEpatents

    Andresen, Brian D.; Miller, Fred S.

    1999-01-01

    An ultratrace detector system for hand-held gas chromatography having high sensitivity, for example, to emissions generated during production of weapons, biological compounds, drugs, etc. The detector system is insensitive to water, air, helium, argon, oxygen, and C0.sub.2. The detector system is basically composed of a hand-held capillary gas chromatography (GC), an insulated heated redox-chamber, a detection chamber, and a vapor trap. For example, the detector system may use gas phase redox reactions and spectral absorption of mercury vapor. The gas chromatograph initially separates compounds that percolate through a bed of heated mercuric oxide (HgO) in a silica--or other metal--aerogel material which acts as an insulator. Compounds easily oxidized by HgO liberate atomic mercury that subsequently pass through a detection chamber which includes a detector cell, such as quartz, that is illuminated with a 254 nm ultra-violet (UV) mercury discharge lamp which generates the exact mercury absorption bands that are used to detect the liberated mercury atoms. Atomic mercury strongly absorbs 254 nm energy is therefore a specific signal for reducing compounds eluting from the capillary GC, whereafter the atomic mercury is trapped for example, in a silicon-aerogel trap.

  15. Immersive Input Display Device (I2D2) for tactical information viewing

    NASA Astrophysics Data System (ADS)

    Tremper, David E.; Burnett, Kevin P.; Malloy, Andrew R.; Wert, Robert

    2006-05-01

    Daylight readability of hand-held displays has been an ongoing issue for both commercial and military applications. In an effort to reduce the effects of ambient light on the readability of military displays, the Naval Research Laboratory (NRL) began investigating and developing advanced hand-held displays. Analysis and research of display technologies with consideration for vulnerability to environmental conditions resulted in the complete design and fabrication of the hand-held Immersive Input Display Device (I2D2) monocular. The I2D2 combines an Organic Light Emitting Diode (OLED) SVGA+ micro-display developed by eMagin Corporation with an optics configuration inside a cylindrical housing. A rubber pressure-eyecup allows view ability only when the eyecup is depressed, eliminating light from both entering and leaving the device. This feature allows the I2D2 to be used during the day, while not allowing ambient light to affect the readability. It simultaneously controls light leakage, effectively eliminating the illumination, and thus preserving the tactical position, of the user in the dark. This paper will examine the characteristics and introduce the design of the I2D2.

  16. 'Toy' laser macular burns in children: 12-month update.

    PubMed

    Raoof, N; O'Hagan, J; Pawlowska, N; Quhill, F

    2016-03-01

    There is increasing evidence that high-powered hand-held laser devices cause retinal injury. We present 12-month follow-up data for three patients that we previously reported with such retinal injuries. A retrospective case series of three children with maculopathy secondary to exposure to high-power hand-held laser devices. All children underwent clinical examination and spectral domain optical coherence tomography (SD-OCT) at presentation and follow-up. Fundus-controlled microperimetry was also undertaken 12-19 months after exposure. Three children sustained macular injury after exposure to a high-powered hand-held laser. Acutely, they presented with a 'vitelliform-like' maculopathy with reduced vision. Over the course of follow-up, the best corrected Snellen acuity in all three patients improved to 'normal' levels (range 6/6-6/9). Long-term deficits in foveal retinal sensitivity were identified in two patients using fundus-controlled microperimetry. SD-OCT imaging showed persistent disruption of the foveal outer photoreceptor layers in all three children. Although visual acuity improved over time, deficits in microperimetry and SD-OCT persisted. All three children had retinal pigment epithelium changes, requiring follow-up for longer-term sequelae of laser injuries such as expansion of retinal atrophy and development of choroidal neovascular membranes.

  17. A comparison of the cell-phone driver and the drunk driver

    DOT National Transportation Integrated Search

    2006-01-01

    Synopsis The authors find no difference in impairment due to hands-free compared to hand-held cell phone use, and that the participants in the two cell phone conditions were involved in more rear-end collisions and reacted 9% more slowly to vehic...

  18. Laser Safety Evaluation of the MILES and Mini MILES Laser Emitting Components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    AUGUSTONI, ARNOLD L.

    Laser safety evaluation and output emission measurements were performed (during October and November 2001) on SNL MILES and Mini MILES laser emitting components. The purpose, to verify that these components, not only meet the Class 1 (eye safe) laser hazard criteria of the CDRH Compliance Guide for Laser Products and 21 CFR 1040 Laser Product Performance Standard; but also meet the more stringent ANSI Std. z136.1-2000 Safe Use of Lasers conditions for Class 1 lasers that govern SNL laser operations. The results of these measurements confirmed that all of the Small Arms Laser Transmitters, as currently set (''as is''), meetmore » the Class 1 criteria. Several of the Mini MILES Small Arms Transmitters did not. These were modified and re-tested and now meet the Class 1 laser hazard criteria. All but one System Controllers (hand held and rifle stock) met class 1 criteria for single trigger pulls and all presented Class 3a laser hazard levels if the trigger is held (continuous emission) for more than 5 seconds on a single point target. All units were Class 3a for ''aided'' viewing. These units were modified and re-tested and now meet the Class 1 hazard criteria for both ''aided'' as well as ''unaided'' viewing. All the Claymore Mine laser emitters tested are laser hazard Class 1 for both ''aided'' as well as ''unaided'' viewing.« less

  19. 76 FR 80886 - Approval for Manufacturing Authority; Foreign-Trade Zone 26; Makita Corporation of America; (Hand...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-27

    ... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [Order No. 1803] Approval for Manufacturing Authority; Foreign-Trade Zone 26; Makita Corporation of America; (Hand-Held/Stationary Power Tool and Gasoline/Electric-Powered Lawn and Garden Product Manufacturing); Buford, GA Pursuant to its authority...

  20. Shifting attention across near and far spaces: implications for the use of hands-free cell phones while driving.

    PubMed

    Ferlazzo, Fabio; Fagioli, Sabrina; Di Nocera, Francesco; Sdoia, Stefano

    2008-11-01

    In three experiments, participants performed two tasks concurrently during driving. In the peripheral detection task, they responded manually to visual stimuli delivered through a LED placed on the internal rear mirror; in the conversation task, they were engaged in a conversation with a passenger, or through earphone-operated, loudspeaker-operated, or hand-held cell phones. Results showed that drivers were slower at responding to the visual stimuli when conversing through a hand-held cell phone or an earphone-operated cell phone than when conversing through a loudspeaker-operated cell phone or with a passenger. These results suggest that due to the brain coding the space into multiple representations, devices that make phone conversations taking place in the near, personal space make drivers slower at responding to visual stimuli, compared to devices that make the conversation occurring in a far space.

  1. Real-time Graphics Processing Unit Based Fourier Domain Optical Coherence Tomography and Surgical Applications

    NASA Astrophysics Data System (ADS)

    Zhang, Kang

    2011-12-01

    In this dissertation, real-time Fourier domain optical coherence tomography (FD-OCT) capable of multi-dimensional micrometer-resolution imaging targeted specifically for microsurgical intervention applications was developed and studied. As a part of this work several ultra-high speed real-time FD-OCT imaging and sensing systems were proposed and developed. A real-time 4D (3D+time) OCT system platform using the graphics processing unit (GPU) to accelerate OCT signal processing, the imaging reconstruction, visualization, and volume rendering was developed. Several GPU based algorithms such as non-uniform fast Fourier transform (NUFFT), numerical dispersion compensation, and multi-GPU implementation were developed to improve the impulse response, SNR roll-off and stability of the system. Full-range complex-conjugate-free FD-OCT was also implemented on the GPU architecture to achieve doubled image range and improved SNR. These technologies overcome the imaging reconstruction and visualization bottlenecks widely exist in current ultra-high speed FD-OCT systems and open the way to interventional OCT imaging for applications in guided microsurgery. A hand-held common-path optical coherence tomography (CP-OCT) distance-sensor based microsurgical tool was developed and validated. Through real-time signal processing, edge detection and feed-back control, the tool was shown to be capable of track target surface and compensate motion. The micro-incision test using a phantom was performed using a CP-OCT-sensor integrated hand-held tool, which showed an incision error less than +/-5 microns, comparing to >100 microns error by free-hand incision. The CP-OCT distance sensor has also been utilized to enhance the accuracy and safety of optical nerve stimulation. Finally, several experiments were conducted to validate the system for surgical applications. One of them involved 4D OCT guided micro-manipulation using a phantom. Multiple volume renderings of one 3D data set were performed with different view angles to allow accurate monitoring of the micro-manipulation, and the user to clearly monitor tool-to-target spatial relation in real-time. The system was also validated by imaging multiple biological samples, such as human fingerprint, human cadaver head and small animals. Compared to conventional surgical microscopes, GPU-based real-time FD-OCT can provide the surgeons with a real-time comprehensive spatial view of the microsurgical region and accurate depth perception.

  2. Resource use efficiency of closed plant production system with artificial light: Concept, estimation and application to plant factory

    PubMed Central

    KOZAI, Toyoki

    2013-01-01

    Extensive research has recently been conducted on plant factory with artificial light, which is one type of closed plant production system (CPPS) consisting of a thermally insulated and airtight structure, a multi-tier system with lighting devices, air conditioners and fans, a CO2 supply unit, a nutrient solution supply unit, and an environment control unit. One of the research outcomes is the concept of resource use efficiency (RUE) of CPPS. This paper reviews the characteristics of the CPPS compared with those of the greenhouse, mainly from the viewpoint of RUE, which is defined as the ratio of the amount of the resource fixed or held in plants to the amount of the resource supplied to the CPPS. It is shown that the use efficiencies of water, CO2 and light energy are considerably higher in the CPPS than those in the greenhouse. On the other hand, there is much more room for improving the light and electric energy use efficiencies of CPPS. Challenging issues for CPPS and RUE are also discussed. PMID:24334509

  3. Resource use efficiency of closed plant production system with artificial light: concept, estimation and application to plant factory.

    PubMed

    Kozai, Toyoki

    2013-01-01

    Extensive research has recently been conducted on plant factory with artificial light, which is one type of closed plant production system (CPPS) consisting of a thermally insulated and airtight structure, a multi-tier system with lighting devices, air conditioners and fans, a CO2 supply unit, a nutrient solution supply unit, and an environment control unit. One of the research outcomes is the concept of resource use efficiency (RUE) of CPPS.This paper reviews the characteristics of the CPPS compared with those of the greenhouse, mainly from the viewpoint of RUE, which is defined as the ratio of the amount of the resource fixed or held in plants to the amount of the resource supplied to the CPPS.It is shown that the use efficiencies of water, CO2 and light energy are considerably higher in the CPPS than those in the greenhouse. On the other hand, there is much more room for improving the light and electric energy use efficiencies of CPPS. Challenging issues for CPPS and RUE are also discussed.

  4. Portable digital pressure indicator for calibrating magnetic tape recorders

    NASA Technical Reports Server (NTRS)

    Mccormick, Royce F.; Leighty, Bradley D.

    1989-01-01

    The design of a portable Digital Pressure Indicator (DPI) to be used for calibrating the pressure systems on Langley's magnetic tape recorders is described. High-speed magnetic tape recorders require pressure (0 to 20 psig) for providing an air cushion across the tape guides and a slight vacuum (30 inch H2O) for maintaining the proper number of tape loops in the advance and feed chamber. The DPI is a hand-held device that can be quickly coupled to a magnetic tape recorder and includes a two-position switch for selecting either measured pressure or vacuum, to be displayed digitally in engineering units (psig or inches H2O). The DPI is currently in use in Langley's Analysis and Computation Division.

  5. Cataloging and indexing - The development of the Space Shuttle mission data base and catalogs from earth observations hand-held photography

    NASA Technical Reports Server (NTRS)

    Nelson, Raymond M.; Willis, Kimberly J.; Daley, William J.; Brumbaugh, Fred R.; Bremer, Jeffrey M.

    1992-01-01

    All earth-looking photographs acquired by Space Shuttle astronauts are identified, located, and catalogued after each mission. The photographs have been entered into a computerized database at the NASA Johnson Space Center. The database in its two modes - computer and catalog - is organized and presented to provide a scope and level of detail designed to be useful in Earth science activities, resource management, environmental studies, and public affairs. The computerized database can be accessed free through standard communication networks 24 hours a day, and the catalogs are distributed throughout the world. Photograph viewing centers are available in the United States, and photographic copies can be obtained through government-supported centers.

  6. The detection of improvised nonmilitary peroxide based explosives using a titania nanotube array sensor.

    PubMed

    Banerjee, Subarna; Mohapatra, Susanta K; Misra, Mano; Mishra, Indu B

    2009-02-18

    There is a critical need to develop an efficient, reliable and highly selective sensor for the detection of improvised nonmilitary explosives. This paper describes the utilization of functionalized titania nanotube arrays for sensing improvised organic peroxide explosives such as triacetone triperoxide (TATP). TATP forms complexes with titania nanotube arrays (prepared by anodization and sensitized with zinc ions) and thus affects the electron state of the nanosensing device, which is signaled as a change in current of the overall nanotube material. The response is rapid and a signal of five to eight orders of magnitude is observed. These nanotube array sensors can be used as hand-held miniaturized devices as well as large scale portable units for military and homeland security applications.

  7. The view from the Shuttle Orbiter - Observing the oceans from manned space flights

    NASA Technical Reports Server (NTRS)

    Kaltenbach, J. L.; Helfert, M. R.; Wells, G. L.

    1984-01-01

    Examples of earth-looking hand-held photography and orbital sensor imagery of ocean features and phenomena in the framework of the Space Shuttle Earth Observations Project are presented. These include images of a floating substance in Capricorn Channel off northeastern Queensland, Australia; atolls in the central Maldive Islands; a spiral eddy and probable oil slick in the Caribbean Sea north of Aruba; and spiral eddies recorded in sun glint over the Mozambique Channel. It is concluded that the observation of the world's oceans during Shuttle missions with the trained eyes of the crewmen and documentation with hand-held photography add a significant dimension to the remote sensing of the ocean.

  8. The First U.S. Spacewalk in HD -SILENT

    NASA Image and Video Library

    1965-06-03

    During the Gemini 4 mission on June 3, 1965, Ed White became the first American to conduct a spacewalk. The spacewalk started at 3:45 p.m. EDT on the third orbit when White opened the hatch and used the hand-held maneuvering oxygen-jet gun to push himself out of the capsule. The EVA started over the Pacific Ocean near Hawaii and lasted 23 minutes, ending over the Gulf of Mexico. Initially, White propelled himself to the end of the 8-meter tether and back to the spacecraft three times using the hand-held gun. After the first three minutes the fuel ran out and White maneuvered by twisting his body and pulling on the tether.

  9. Hand-Held Devices Detect Explosives and Chemical Agents

    NASA Technical Reports Server (NTRS)

    2010-01-01

    Ion Applications Inc., of West Palm Beach, Florida, partnered with Ames Research Center through Small Business Innovation Research (SBIR) agreements to develop a miniature version ion mobility spectrometer (IMS). While NASA was interested in the instrument for detecting chemicals during exploration of distant planets, moons, and comets, the company has incorporated the technology into a commercial hand-held IMS device for use by the military and other public safety organizations. Capable of detecting and identifying molecules with part-per-billion sensitivity, the technology now provides soldiers with portable explosives and chemical warfare agent detection. The device is also being adapted for detecting drugs and is employed in industrial processes such as semiconductor manufacturing.

  10. Human-scale interaction for virtual model displays: a clear case for real tools

    NASA Astrophysics Data System (ADS)

    Williams, George C.; McDowall, Ian E.; Bolas, Mark T.

    1998-04-01

    We describe a hand-held user interface for interacting with virtual environments displayed on a Virtual Model Display. The tool, constructed entirely of transparent materials, is see-through. We render a graphical counterpart of the tool on the display and map it one-to-one with the real tool. This feature, combined with a capability for touch- sensitive, discrete input, results in a useful spatial input device that is visually versatile. We discuss the tool's design and interaction techniques it supports. Briefly, we look at the human factors issues and engineering challenges presented by this tool and, in general, by the class of hand-held user interfaces that are see-through.

  11. The different ways to obtain digital images of urine microscopy findings: Their advantages and limitations.

    PubMed

    Fogazzi, G B; Garigali, G

    2017-03-01

    We describe three ways to take digital images of urine sediment findings. Way 1 encompasses a digital camera permanently mounted on the microscope and connected with a computer equipped with a proprietary software to acquire, process and store the images. Way 2 is based on the use of inexpensive compact digital cameras, held by hands - or mounted on a tripod - close to one eyepiece of the microscope. Way 3 is based on the use of smartphones, held by hands close to one eyepiece of the microscope or connected to the microscope by an adapter. The procedures, advantages and limitations of each way are reported. Copyright © 2017. Published by Elsevier B.V.

  12. Characterization of Strength and Function in Ambulatory Adults With GNE Myopathy.

    PubMed

    Argov, Zohar; Bronstein, Faye; Esposito, Alicia; Feinsod-Meiri, Yael; Florence, Julaine M; Fowler, Eileen; Greenberg, Marcia B; Malkus, Elizabeth C; Rebibo, Odelia; Siener, Catherine S; Caraco, Yoseph; Kolodny, Edwin H; Lau, Heather A; Pestronk, Alan; Shieh, Perry; Skrinar, Alison M; Mayhew, Jill E

    2017-09-01

    To characterize the pattern and extent of muscle weakness and impact on physical functioning in adults with GNEM. Strength and function were assessed in GNEM subjects (n = 47) using hand-held dynamometry, manual muscle testing, upper and lower extremity functional capacity tests, and the GNEM-Functional Activity Scale (GNEM-FAS). Profound upper and lower muscle weakness was measured using hand-held dynamometry in a characteristic pattern, previously described. Functional tests and clinician-reported outcomes demonstrated the consequence of muscle weakness on physical functioning. The characteristic pattern of upper and lower muscle weakness associated with GNEM and the resulting functional limitations can be reliably measured using these clinical outcome assessments of muscle strength and function.

  13. Electronic Hand Calculators: The Implications for Pre-College Education. Final Report. Abbreviated Version.

    ERIC Educational Resources Information Center

    Suydam, Marilyn, Comp.

    This volume reports research conducted to provide the National Science Foundation (NSF) with information concerning the existing range of beliefs and opinions about the impact of the hand-held calculator on pre-college educational practice. A literature search and several surveys of groups of individuals involved in calculator manufacture and…

  14. 30 CFR 77.1010 - Collaring holes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Collaring holes. 77.1010 Section 77.1010... Control § 77.1010 Collaring holes. (a) Starter steels shall be used when collaring holes with hand-held drills. (b) Men shall not hold the drill steel while collaring holes, or rest their hands on the chuck or...

  15. 30 CFR 77.1010 - Collaring holes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Collaring holes. 77.1010 Section 77.1010... Control § 77.1010 Collaring holes. (a) Starter steels shall be used when collaring holes with hand-held drills. (b) Men shall not hold the drill steel while collaring holes, or rest their hands on the chuck or...

  16. 30 CFR 77.1010 - Collaring holes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Collaring holes. 77.1010 Section 77.1010... Control § 77.1010 Collaring holes. (a) Starter steels shall be used when collaring holes with hand-held drills. (b) Men shall not hold the drill steel while collaring holes, or rest their hands on the chuck or...

  17. 30 CFR 77.1010 - Collaring holes.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Collaring holes. 77.1010 Section 77.1010... Control § 77.1010 Collaring holes. (a) Starter steels shall be used when collaring holes with hand-held drills. (b) Men shall not hold the drill steel while collaring holes, or rest their hands on the chuck or...

  18. 30 CFR 18.48 - Circuit-interrupting devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... two-pole switch of the “dead-man-control” type that must be held closed by hand and will open when hand pressure is released. (e) A machine designed to operate from both trolley wire and portable cable.... Such a switch shall be designed to prevent electrical connection to the machine frame when the cable is...

  19. 30 CFR 18.48 - Circuit-interrupting devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... two-pole switch of the “dead-man-control” type that must be held closed by hand and will open when hand pressure is released. (e) A machine designed to operate from both trolley wire and portable cable.... Such a switch shall be designed to prevent electrical connection to the machine frame when the cable is...

  20. 36 CFR 7.74 - Virgin Islands National Park.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of the park is prohibited. (3) The species of crustaceans known as Florida Spiny Lobster (Panulirus argus) may be taken by hand or hand-held hook. No person shall take female lobsters with eggs; or take more than two lobsters per person per day; or have in possession more than two days' limit: Provided...

  1. 36 CFR 7.74 - Virgin Islands National Park.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of the park is prohibited. (3) The species of crustaceans known as Florida Spiny Lobster (Panulirus argus) may be taken by hand or hand-held hook. No person shall take female lobsters with eggs; or take more than two lobsters per person per day; or have in possession more than two days' limit: Provided...

  2. 30 CFR 77.1010 - Collaring holes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Collaring holes. 77.1010 Section 77.1010... Control § 77.1010 Collaring holes. (a) Starter steels shall be used when collaring holes with hand-held drills. (b) Men shall not hold the drill steel while collaring holes, or rest their hands on the chuck or...

  3. Instant Read on Reading, in Palms of Their Hands

    ERIC Educational Resources Information Center

    Olson, Lynn

    2007-01-01

    This article discusses teachers' use of hand-held computers in a rural New Mexico district to assess student's reading progress. With the help of a federal Reading First grant, the district began using the DIBELS assessments across its elementary schools along with the mCLASS: DIBELS assessment and reporting system. The district's experience helps…

  4. A hand-held EPR scanner for transcutaneous oximetry

    NASA Astrophysics Data System (ADS)

    Wolfson, Helen; Ahmad, Rizwan; Twig, Ygal; Blank, Aharon; Kuppusamy, Periannan

    2015-03-01

    Cutaneous (skin) oxygenation is an important prognostic factor for the treatment of chronic wounds, skin cancer, diabetes side effects, and limb amputation. Currently, there are no reliable methods for measuring this parameter. Oximetry, using electron paramagnetic resonance (EPR) spectroscopy, is emerging as a potential tool for clinical oximetry, including cutaneous applications. The problem with EPR oximetry, however, is that the conventional EPR design requires the use of a large magnet that can generate homogeneous field across the sample, making it unattractive for clinical practice. We present a novel approach that makes use of a miniature permanent magnet, combined with a small microwave resonator, to enable the acquisition of EPR signals from paramagnetic species placed on the skin. The instrumentation consists of a hand-held, modular, cylindrical probehead with overall dimensions of 36-mm diameter and 24-mm height, with 150-g weight. The probehead includes a Halbach array of 16 pieces (4×4×8 mm3) of Sm-Co permanent magnet and a loop-gap resonator (2.24 GHz). Preliminary measurements using a Hahn-echo pulse sequence (800 echos in 20 ms) showed a signalto- noise ratio of ~70 compared to ~435 in a homogenous magnet under identical settings. Further work is in progress to improve the performance of the probehead and to optimize the hand-held system for clinical use

  5. Development and characterization of a round hand-held silicon photomultiplier based gamma camera for intraoperative imaging

    PubMed Central

    Popovic, Kosta; McKisson, Jack E.; Kross, Brian; Lee, Seungjoon; McKisson, John; Weisenberger, Andrew G.; Proffitt, James; Stolin, Alexander; Majewski, Stan; Williams, Mark B.

    2017-01-01

    This paper describes the development of a hand-held gamma camera for intraoperative surgical guidance that is based on silicon photomultiplier (SiPM) technology. The camera incorporates a cerium doped lanthanum bromide (LaBr3:Ce) plate scintillator, an array of 80 SiPM photodetectors and a two-layer parallel-hole collimator. The field of view is circular with a 60 mm diameter. The disk-shaped camera housing is 75 mm in diameter, approximately 40.5 mm thick and has a mass of only 1.4 kg, permitting either hand-held or arm-mounted use. All camera components are integrated on a mobile cart that allows easy transport. The camera was developed for use in surgical procedures including determination of the location and extent of primary carcinomas, detection of secondary lesions and sentinel lymph node biopsy (SLNB). Here we describe the camera design and its principal operating characteristics, including spatial resolution, energy resolution, sensitivity uniformity, and geometric linearity. The gamma camera has an intrinsic spatial resolution of 4.2 mm FWHM, an energy resolution of 21.1 % FWHM at 140 keV, and a sensitivity of 481 and 73 cps/MBq when using the single- and double-layer collimators, respectively. PMID:28286345

  6. Segmentation of Environmental Time Lapse Image Sequences for the Determination of Shore Lines Captured by Hand-Held Smartphone Cameras

    NASA Astrophysics Data System (ADS)

    Kröhnert, M.; Meichsner, R.

    2017-09-01

    The relevance of globally environmental issues gains importance since the last years with still rising trends. Especially disastrous floods may cause in serious damage within very short times. Although conventional gauging stations provide reliable information about prevailing water levels, they are highly cost-intensive and thus just sparsely installed. Smartphones with inbuilt cameras, powerful processing units and low-cost positioning systems seem to be very suitable wide-spread measurement devices that could be used for geo-crowdsourcing purposes. Thus, we aim for the development of a versatile mobile water level measurement system to establish a densified hydrological network of water levels with high spatial and temporal resolution. This paper addresses a key issue of the entire system: the detection of running water shore lines in smartphone images. Flowing water never appears equally in close-range images even if the extrinsics remain unchanged. Its non-rigid behavior impedes the use of good practices for image segmentation as a prerequisite for water line detection. Consequently, we use a hand-held time lapse image sequence instead of a single image that provides the time component to determine a spatio-temporal texture image. Using a region growing concept, the texture is analyzed for immutable shore and dynamic water areas. Finally, the prevalent shore line is examined by the resultant shapes. For method validation, various study areas are observed from several distances covering urban and rural flowing waters with different characteristics. Future work provides a transformation of the water line into object space by image-to-geometry intersection.

  7. Utility of hand-held echocardiography in outpatient pediatric cardiology management.

    PubMed

    Riley, Alan; Sable, Craig; Prasad, Aparna; Spurney, Christopher; Harahsheh, Ashraf; Clauss, Sarah; Colyer, Jessica; Gierdalski, Marcin; Johnson, Ashley; Pearson, Gail D; Rosenthal, Joanna

    2014-12-01

    Adult patient series have shown hand-held echocardiography (echo) units (HHE) to be accurate for rapid diagnosis and triage. This is the first study to evaluate the ability of HHE to inform decision making in outpatient pediatric cardiology. New pediatric cardiology patients in outpatient clinics staffed by six pediatric cardiologists (experience 1-17 years) were prospectively enrolled if an echocardiogram (echo) was ordered during their initial visit. After history and physical examination and before a standard echo, the cardiologists performed a bedside HHE examination (GE Vscan 1.7-3.8 MHz), documented findings, and made a clinical decision. Diagnoses and decisions based on HHE were compared with final management after the standard echo. The study enrolled 101 subjects (ages 9 days to 19 years). The cardiologists considered HHE imaging adequate for decision making for 80 of the 101 subjects. For 77 of the 80 subjects with acceptable HHE imaging (68/68 normal and 9/12 abnormal standard echoes), the HHE-based primary diagnoses and decisions agreed with the final management. The sensitivity of HHE was 75 % (95 % confidence interval [CI] 43-94 %) and the positive predictive value 100 % (95 % CI 66-100 %) for pediatric heart disease. The agreement between standard echocardiography and HHE imaging was substantial (κ = 0.82). Excluding one of the least experienced cardiologists, HHE provided the basis for correct cardiac diagnoses and management for all the subjects with acceptable HHE imaging (58/58 normal and 9/9 abnormal echoes). In outpatient pediatric cardiology, HHE has potential as a tool to complement physical examination. Further investigation is needed to evaluate how value improves with clinical experience.

  8. The NITON{reg_sign} XL-800 Series Multi-Element Spectrum Analyzer (Alloy Analyzer). Innovative Technology Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2000-04-01

    The NITON{reg_sign} 800 series analyzer is a hand-held, battery operated unit that measures 8-in x 3-in x 2-in and weighs 2.5 pounds. The analyzer uses x-ray fluorescence spectrum analysis to identify and quantify elements in metal and then compares the readings to a built-in library to determine a metal's alloy. The library contains 300 elements and alloys, and can be customized to identify other elements and alloys (depending on the sources in the instrument). The basic unit utilizes a Cadmium-109 source, but each analyzer unit can hold up to two sources. These sources include Iron-55 and Americium-241. Pushing a safetymore » button located on the side of the unit and placing it against a surface opens the shutter window. Within seconds the unit beeps, and displays the results. The analyzer stores up to 1,000 data sets, including sample identification codes using a barcode reader. The data is easily downloaded to a conventional computer when sampling has been completed. Batteries are good for 8-hrs and charge in less than 2 hours and it can be carried, shipped, or transported without exterior labeling, conforming to 49 CFR 143.421.« less

  9. View of portion of Western United States as seen by Skylab

    NASA Image and Video Library

    1974-01-10

    SL4-139-4040 (10 Jan. 1974) --- An oblique view of a portion of the Western United States, as photographed from the Skylab space station in Earth orbit by one of the Skylab 4 crewmen. The camera used was a hand-held 70mm Hasselblad, with SO-368 medium-speed Ektachrome film. This photograph is one of a stereo pair (the other being 4039) taken to support the hydrological studies of the changing snow patterns in several watersheds. Stereo analysis will enable snow to be distinguished from clouds quantitatively. In a qualitative sense, the clouds are the fuzzy white, whereas the snow is distinct white. The area covered is from the Colorado Springs, Colorado area at the south to (and beyond) the Black Hills, South Dakota area. The Black Forest between Colorado Springs and Denver is evident as are the mountains west of these cities. South Park, west of Colorado Springs, and the South Platte River running north and east from Denver are two other conspicuous features. Photo credit: NASA

  10. Reconstructive Microsurgery: The Future Is Today.

    PubMed

    Amin, Kavit; Mohan, Anita T

    2017-01-01

    This reconstructive microsurgery course will run yearly and was borne and popularized from its infant meeting the year before, primarily focused on perforator flaps. It is a 2-day course updating residents/registrars to attending physicians/consultants about the most topical advancements in microvascular reconstructive surgery. The course is held at the New York University Langone Hospital in the United States.The timetable is primarily lecture based with the advantage of live-surgical procedures by world-renowned faculty. The timetable includes, but not limited to, facial/hand vascularized composite allotransplantation, upper/lower limb, breast, head and neck, transgender, and lymphedema surgery. Lectures were highly informative and there was ample time for case discussion with the appreciation that managing complex situations often requires input from other colleagues. The faculty focused on the lessons they have learned and potential pitfalls to avoid. The faculty was comprised of leading experts in reconstructive microsurgery from Europe, Korea, and throughout the United States.The primary emphasis of the course was to appreciate the global recognition in advances in microsurgery.

  11. EXTRAVEHICULAR ACTIVITY (EVA) - GEMINI-TITAN (GT)-4

    NASA Image and Video Library

    1965-06-03

    S65-29766 (3 June 1965) --- Astronaut Edward H. White II, pilot for the Gemini-Titan 4 (GT-4) spaceflight, floats in the zero-gravity of space during the third revolution of the GT-4 spacecraft. White wears a specially designed spacesuit. His face is shaded by a gold-plated visor to protect him from unfiltered rays of the sun. In his right hand he carries a Hand-Held Self-Maneuvering Unit (HHSMU) that gives him control over his movements in space. White also wears an emergency oxygen chest pack; and he carries a camera mounted on the HHSMU for taking pictures of the sky, Earth and the GT-4 spacecraft. He is secured to the spacecraft by a 25-feet umbilical line and a 23-feet tether line. Both lines are wrapped together in gold tape to form one cord. Astronaut James A. McDivitt, command pilot, remained inside the spacecraft during the extravehicular activity (EVA). Photo credit: NASA EDITOR'S NOTE: Astronaut Edward H. White II died in the Apollo/Saturn 204 fire at Cape Kennedy on Jan. 27, 1967.

  12. S65-29730

    NASA Image and Video Library

    1965-06-08

    S65-29730 (3 June 1965) --- Astronaut Edward H. White II, pilot for the Gemini-Titan 4 (GT-4) spaceflight, floats in the zero-gravity of space during the third revolution of the GT-4 spacecraft. White wears a specially designed spacesuit. His face is shaded by a gold-plated visor to protect him from unfiltered rays of the sun. In his right hand he carries a Hand-Held Self-Maneuvering Unit (HHSMU) that gives him control over his movements in space. White also wears an emergency oxygen chest pack; and he carries a camera mounted on the HHSMU for taking pictures of the sky, Earth and the GT-4 spacecraft. He is secured to the spacecraft by a 25-feet umbilical line and a 23-feet tether line. Both lines are wrapped together in gold tape to form one cord. Astronaut James A. McDivitt, command pilot, remained inside the spacecraft during the extravehicular activity (EVA). Photo credit: NASA EDITOR'S NOTE: Astronaut Edward H. White II died in the Apollo/Saturn 204 fire at Cape Kennedy on Jan. 27, 1967.

  13. ASTRONAUT EDWARD H. WHITE II - GEMINI-TITAN (GT)-IV - ZERO GRAVITY - OUTER SPACE

    NASA Image and Video Library

    2015-03-20

    S65-30427 (3 June 1965) --- Astronaut Edward H. White II, pilot for the Gemini-Titan 4 (GT-4) spaceflight, floats in the zero-gravity of space during the third revolution of the GT-4 spacecraft. White wears a specially designed spacesuit. His face is shaded by a gold-plated visor to protect him from unfiltered rays of the sun. In his right hand he carries a Hand-Held Self-Maneuvering Unit (HHSMU) that gives him control over his movements in space. White also wears an emergency oxygen chest pack; and he carries a camera mounted on the HHSMU for taking pictures of the sky, Earth and the GT-4 spacecraft. He is secured to the spacecraft by a 25-feet umbilical line and a 23-feet tether line. Both lines are wrapped together in gold tape to form one cord. Astronaut James A. McDivitt, command pilot, remained inside the spacecraft during the extravehicular activity (EVA). Photo credit: NASA EDITOR'S NOTE: Astronaut Edward H. White II died in the Apollo/Saturn 204 fire at Cape Kennedy on Jan. 27, 1967.

  14. An Examination of a Response to Intervention Program in Texas Elementary Schools in Relation to the Special Education Program

    ERIC Educational Resources Information Center

    Vardy, Tamara Neff

    2016-01-01

    Students in public education are more at risk now than ever before. Schools were held to increasingly higher levels of accountability and it was the individual student that was held accountable for increasing standards and knowledge. This study addressed the Response to Intervention mandate handed down by federal and state governments. In effort…

  15. Augmented Reality and Mobile Art

    NASA Astrophysics Data System (ADS)

    Gwilt, Ian

    The combined notions of augmented-reality (AR) and mobile art are based on the amalgamation of a number of enabling technologies including computer imaging, emergent display and tracking systems and the increased computing-power in hand-held devices such as Tablet PCs, smart phones, or personal digital assistants (PDAs) which have been utilized in the making of works of art. There is much published research on the technical aspects of AR and the ongoing work being undertaken in the development of faster more efficient AR systems [1] [2]. In this text I intend to concentrate on how AR and its associated typologies can be applied in the context of new media art practices, with particular reference to its application on hand-held or mobile devices.

  16. Characterization of Strength and Function in Ambulatory Adults With GNE Myopathy

    PubMed Central

    Argov, Zohar; Bronstein, Faye; Esposito, Alicia; Feinsod-Meiri, Yael; Florence, Julaine M.; Fowler, Eileen; Greenberg, Marcia B.; Malkus, Elizabeth C.; Rebibo, Odelia; Siener, Catherine S.; Caraco, Yoseph; Kolodny, Edwin H.; Lau, Heather A.; Pestronk, Alan; Shieh, Perry; Mayhew, Jill E.

    2017-01-01

    Abstract Objective: To characterize the pattern and extent of muscle weakness and impact on physical functioning in adults with GNEM. Methods: Strength and function were assessed in GNEM subjects (n = 47) using hand-held dynamometry, manual muscle testing, upper and lower extremity functional capacity tests, and the GNEM-Functional Activity Scale (GNEM-FAS). Results: Profound upper and lower muscle weakness was measured using hand-held dynamometry in a characteristic pattern, previously described. Functional tests and clinician-reported outcomes demonstrated the consequence of muscle weakness on physical functioning. Conclusions: The characteristic pattern of upper and lower muscle weakness associated with GNEM and the resulting functional limitations can be reliably measured using these clinical outcome assessments of muscle strength and function. PMID:28827485

  17. Hand-Held Femtogram Detection of Hazardous Picric Acid with Hydrophobic Ag Nanopillar SERS Substrates and Mechanism of Elasto-Capillarity.

    PubMed

    Hakonen, Aron; Wang, FengChao; Andersson, Per Ola; Wingfors, Håkan; Rindzevicius, Tomas; Schmidt, Michael Stenbæk; Soma, Venugopal Rao; Xu, Shicai; Li, YingQi; Boisen, Anja; Wu, HengAn

    2017-02-24

    Picric acid (PA) is a severe environmental and security risk due to its unstable, toxic, and explosive properties. It is also challenging to detect in trace amounts and in situ because of its highly acidic and anionic character. Here, we assess sensing of PA under nonlaboratory conditions using surface-enhanced Raman scattering (SERS) silver nanopillar substrates and hand-held Raman spectroscopy equipment. The advancing elasto-capillarity effects are explained by molecular dynamics simulations. We obtain a SERS PA detection limit on the order of 20 ppt, corresponding attomole amounts, which together with the simple analysis methodology demonstrates that the presented approach is highly competitive for ultrasensitive analysis in the field.

  18. Feasibility and safety of a novel in vivo model to assess playground falls in children.

    PubMed

    Ehrlich, Peter F; Young, Justin G; Ulin, Sheryl; Wooley, Charles; Armstrong, Thomas J; Buschmann, Bethany; Galecki, Andrzej; Ashton-Miller, James A

    2013-07-01

    Falls are the leading cause of nonfatal unintentional injuries among hospitalized children with playground equipment accounting for more than 50%. National standards for playground rung and rail design exist, but there a lack of in vivo models available to test these standards. We developed a novel in vivo model to test rung and rail design. We report the feasibility and safety of the model. A device was built to simulate children hanging onto a playground bar until their hand slips off. This was defined as breakaway strength. The handle unit was mounted on a vertical cable that was mechanically raised and lowered using a linear actuator controlled by the experimenter. The unit was padded and contained a video camera that recorded the posture of the hand during each trial. Breakaway force and torque were recorded as they held onto the handle by LabView software. In addition, standard anthropometrics and grip strength were recorded. Biomedical engineering approved the device. There were 425 eligible students aged 5 years to 11 years. Of these, 93% (397) participated (212 males and 185 females). Ninety-nine percent (396 of 397) completed all three experimental stations, one declined because of fear. There were no injuries and no falls. Average time to complete the study was 22 ± 0.5 minutes. Ninety-one percent of participants were right handed; the ethnicity was representative of the local area with 79% being white. Mean ± SD height, weight, and body mass index for the 397 participants were 1.28 ± 0.11 m, 28.0 ± 8.12 kg, and 16.31 ± 2.59 kg/m², respectively. Hand size, grip strength, and maximum breakaway force increased with age. This model is safe and feasible and maybe a viable method to assess rung and rail design for playgrounds.

  19. STS-73 Flight Day 5

    NASA Technical Reports Server (NTRS)

    1995-01-01

    On this fifth day of the STS-73 sixteen day mission, the crew Cmdr. Kenneth Bowersox, Pilot Kent Rominger, Payload Specialists Albert Sacco and Fred Leslie, and Mission Specialists Kathryn Thornton, Catherine 'Cady' Coleman, and Michael Lopez-Alegria are shown performing several of the spaceborne experiments onboard the United States Microgravity Lab-2 (USML-2). These experiments are downlinked to Mission Control from the Spacelab using the High-Packed Digital Television (HI-PAC) systems onboard the Shuttle. The experiments shown include the Drop Physics Module (DPM) experiment, the Surface Tension Driven Convection Experiment (STDCE), the Protein Crystal Growth (PCG) experiment, and a Hand-Held Diffusion Test Cell experiment. Lopez-Alegria is interviewed in Spanish by two Spanish radio show hosts. Earth views include cloud cover, the Earth's horizon and atmospheric boundary layers, and several oceans.

  20. 40 CFR 63.781 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... with hand-held, nonrefillable, aerosol containers or to unsaturated polyester resin (i.e., fiberglass... startups, shutdowns, and malfunctions and continuous monitoring do not apply to this source category unless...

  1. 40 CFR 63.781 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... with hand-held, nonrefillable, aerosol containers or to unsaturated polyester resin (i.e., fiberglass... startups, shutdowns, and malfunctions and continuous monitoring do not apply to this source category unless...

  2. Language Centres: Are We Holding the Future in Our Hands?

    ERIC Educational Resources Information Center

    Robinson, Ian Michael

    2018-01-01

    With the advent of web 2.0 and the ease of use of many hand-held devices, access to the internet has never been easier. This has been accompanied by a growing range of sites available for learning an L2. These sites offer lessons, explanations, exercises, corrections and feedback. It now becomes time once again to question whether physical bricks…

  3. Neuropsychological Evidence for Visual- and Motor-Based Affordance: Effects of Reference Frame and Object-Hand Congruence

    ERIC Educational Resources Information Center

    Humphreys, Glyn W.; Wulff, Melanie; Yoon, Eun Young; Riddoch, M. Jane

    2010-01-01

    Two experiments are reported that use patients with visual extinction to examine how visual attention is influenced by action information in images. In Experiment 1 patients saw images of objects that were either correctly or incorrectly colocated for action, with the objects held by hands that were congruent or incongruent with those used…

  4. Wire harness twisting aid

    NASA Technical Reports Server (NTRS)

    Casey, E. J.; Commadore, C. C.; Ingles, M. E.

    1980-01-01

    Long wire bundles twist into uniform spiral harnesses with help of simple apparatus. Wires pass through spacers and through hand-held tool with hole for each wire. Ends are attached to low speed bench motor. As motor turns, operator moves hand tool away forming smooth twists in wires between motor and tool. Technique produces harnesses that generate less radio-frequency interference than do irregularly twisted cables.

  5. 26 CFR 1.1223-1 - Determination of period for which capital assets are held.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES General Rules for Determining Capital Gains and... gain or loss in the hands of the taxpayer as the property exchanged. However, this rule shall apply, in... in part in the hands of the taxpayer for determining gain or loss from a sale or exchange as it would...

  6. 31 CFR 535.213 - Direction involving property held by offices of banks in the United States in which Iran or an...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... offices of banks in the United States in which Iran or an Iranian entity has an interest. 535.213 Section....213 Direction involving property held by offices of banks in the United States in which Iran or an... funds or securities legally or beneficially owned by the Government of Iran or its agencies...

  7. 31 CFR 535.213 - Direction involving property held by offices of banks in the United States in which Iran or an...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... offices of banks in the United States in which Iran or an Iranian entity has an interest. 535.213 Section....213 Direction involving property held by offices of banks in the United States in which Iran or an... funds or securities legally or beneficially owned by the Government of Iran or its agencies...

  8. 31 CFR 535.213 - Direction involving property held by offices of banks in the United States in which Iran or an...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... offices of banks in the United States in which Iran or an Iranian entity has an interest. 535.213 Section....213 Direction involving property held by offices of banks in the United States in which Iran or an... funds or securities legally or beneficially owned by the Government of Iran or its agencies...

  9. 31 CFR 535.213 - Direction involving property held by offices of banks in the United States in which Iran or an...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... offices of banks in the United States in which Iran or an Iranian entity has an interest. 535.213 Section....213 Direction involving property held by offices of banks in the United States in which Iran or an... funds or securities legally or beneficially owned by the Government of Iran or its agencies...

  10. 31 CFR 535.213 - Direction involving property held by offices of banks in the United States in which Iran or an...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... offices of banks in the United States in which Iran or an Iranian entity has an interest. 535.213 Section....213 Direction involving property held by offices of banks in the United States in which Iran or an... funds or securities legally or beneficially owned by the Government of Iran or its agencies...

  11. Potential air contamination during CO2 angiography using a hand-held syringe: theoretical considerations and gas chromatography.

    PubMed

    Cho, David R; Cho, Kyung J; Hawkins, Irvin F

    2006-01-01

    To assess air contamination in the hand-held syringes currently used for CO2 delivery and to determine whether there is an association between their position and the rate of air contamination. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO2 at 0.1599 cm2/sec (9.594 cm2/min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Air contamination occurs in hand-held syringes filled with CO2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions.

  12. Hand-Held Sunphotometers for High School Student Construction and Measuring Aerosol Optical Thickness

    NASA Technical Reports Server (NTRS)

    Almonor, Linda; Baldwin, C.; Craig, R.; Johnson, L. P.

    2000-01-01

    Science education is taking the teaching of science from a traditional (lecture) approach to a multidimensional sense-making approach which allows teachers to support students by providing exploratory experiences. Using projects is one way of providing students with opportunities to observe and participate in sense-making activity. We created a learning environment that fostered inquiry-based learning. Students were engaged in a variety of Inquiry activities that enabled them to work in cooperative planning teams where respect for each other was encouraged and their ability to grasp, transform and transfer information was enhanced. Summer, 1998: An air pollution workshop was conducted for high school students in the Medgar Evers College/Middle College High School Liberty Partnership Summer Program. Students learned the basics of meteorology: structure and composition of the atmosphere and the processes that cause weather. The highlight of this workshop was the building of hand-held sunphotometers, which measure the intensity of the sunlight striking the Earth. Summer, 1999: high school students conducted a research project which measured the mass and size of ambient particulates and enhanced our ability to observe through land based measurements changes in the optical depth of ambient aerosols over Brooklyn. Students used hand held Sunphotometers to collect data over a two week period and entered it into the NASA GISS database by way of the internet.

  13. Neurosurgical hand-held optical coherence tomography (OCT) forward-viewing probe

    NASA Astrophysics Data System (ADS)

    Sun, Cuiru; Lee, Kenneth K. C.; Vuong, Barry; Cusimano, Michael; Brukson, Alexander; Mariampillai, Adrian; Standish, Beau A.; Yang, Victor X. D.

    2012-02-01

    A prototype neurosurgical hand-held optical coherence tomography (OCT) imaging probe has been developed to provide micron resolution cross-sectional images of subsurface tissue during open surgery. This new ergonomic hand-held probe has been designed based on our group's previous work on electrostatically driven optical fibers. It has been packaged into a catheter probe in the familiar form factor of the clinically accepted Bayonet shaped neurosurgical non-imaging Doppler ultrasound probes. The optical design was optimized using ZEMAX simulation. Optical properties of the probe were tested to yield an ~20 um spot size, 5 mm working distance and a 3.5 mm field of view. The scan frequency can be increased or decreased by changing the applied voltage. Typically a scan frequency of less than 60Hz is chosen to keep the applied voltage to less than 2000V. The axial resolution of the probe was ~15 um (in air) as determined by the OCT system. A custom-triggering methodology has been developed to provide continuous stable imaging, which is crucial for clinical utility. Feasibility of this probe, in combination with a 1310 nm swept source OCT system was tested and images are presented to highlight the usefulness of such a forward viewing handheld OCT imaging probe. Knowledge gained from this research will lay the foundation for developing new OCT technologies for endovascular management of cerebral aneurysms and transsphenoidal neuroendoscopic treatment of pituitary tumors.

  14. Task and fatigue effects on low-threshold motor units in human hand muscle.

    PubMed

    Enoka, R M; Robinson, G A; Kossev, A R

    1989-12-01

    1. The activity of single motor units was recorded in the first dorsal interosseus muscle of human subjects while they performed an isometric ramp-and-hold maneuver. Motor-unit activity was characterized before and after fatigue by the use of a branched bipolar electrode that was positioned subcutaneously over the test muscle. Activity was characterized in terms of the forces of recruitment and derecruitment and the discharge pattern. The purpose was to determine, before and after fatigue, whether motor-unit activity was affected by the direction in which the force was exerted. 2. Regardless of the task during prefatigue trials, interimpulse intervals were 1) more variable during increases or decreases in force than when force was held constant at the target value (4-6% above the recruitment force), and 2) more clustered around an arbitrary central value than would be expected with a normal (Gaussian) distribution. Both effects were seen during the flexion and abduction tasks. The behavior of low-threshold motor units in first dorsal interosseus is thus largely unaffected by the direction of the force exerted by the index finger. The absence of a task (i.e., a direction of force) effect suggests that the resultant force vector about the metacarpophalangeal joint of the index finger is not coded in terms of discrete populations of motor units, but, rather, it is based on the net muscle activity about the joint. 3. Motor-unit behavior during and after fatigue showed that the relatively homogeneous behavior seen before fatigue could be severely disrupted. The fatiguing protocol involved the continuous repetition, to the endurance limit, of a 15-s ramp-and-hold maneuver in which the abduction target force was 50% of maximum and was held for 10-s epochs (ramps up and down were approximately 2 s each). Motor-unit threshold was assessed by the forces of recruitment and derecruitment associated with each cycle of the fatigue test. Changes in recruitment force during the protocol were either minimal or, when present, not systematic. In contrast, the derecruitment force of all units exhibited a marked and progressive increase over the course of the test. 4. After the fatigue test, when the initial threshold tasks were repeated, the behavior of most motor units changed. These changes included the derecruitment of previously active motor units, the recruitment of additional motor units, and an increased discharge variability of units that remained recruited. The variation in recruitment order seemed to be much greater than that reported previously for nonfatiguing conditions.(ABSTRACT TRUNCATED AT 400 WORDS)

  15. Hand-held spectrophotometer design for textile fabrics

    NASA Astrophysics Data System (ADS)

    Böcekçi, Veysel Gökhan; Yıldız, Kazım

    2017-09-01

    In this study, a hand-held spectrophotometer was designed by taking advantage of the developments in modern optoelectronic technology. Spectrophotometer devices are used to determine the color information from the optic properties of the materials. As an alternative to a desktop spectrophotometer device we have implemented, it is the first prototype, low cost and portable. The prototype model designed for the textile industry can detect the color tone of any fabric. The prototype model consists of optic sensor, processor, display floors. According to the color applied on the optic sensor, it produces special frequency information on its output at that color value. In Arduino type processor, the frequency information is evaluated by the program we have written and the color tone information between 0-255 ton is decided and displayed on the screen.

  16. Digital data from shuttle photography: The effects of platform variables

    NASA Technical Reports Server (NTRS)

    Davis, Bruce E.

    1987-01-01

    Two major criticisms of using Shuttle hand held photography as an Earth science sensor are that it is nondigital, nonquantitative and that it has inconsistent platform characteristics, e.g., variable look angles, especially as compared to remote sensing satellites such as LANDSAT and SPOT. However, these criticisms are assumptions and have not been systematically investigated. The spectral effects of off-nadir views of hand held photography from the Shuttle and their role in interpretation of lava flow morphology on the island of Hawaii are studied. Digitization of photography at JSC and use of LIPS image analysis software in obtaining data is discussed. Preliminary interpretative results of one flow are given. Most of the time was spent in developing procedures and overcoming equipment problems. Preliminary data are satisfactory for detailed analysis.

  17. Cost effective spectral sensor solutions for hand held and field applications

    NASA Astrophysics Data System (ADS)

    Reetz, Edgar; Correns, Martin; Notni, Gunther

    2015-05-01

    Optical spectroscopy is without doubt one of the most important non-contact measurement principles. It is used in a wide range of applications from bio-medical to industrial fields. One recent trend is to miniaturize spectral sensors to address new areas of application. The most common spectral sensor type is based on diffraction gratings, while other types are based on micro mechanical systems (MEMS) or filter technologies. The authors represent the opinion that there is a potentially wide spread field of applications for spectrometers, but the market limits the range of applications since they cannot keep up with targeted cost requirements for consumer products. The present article explains an alternative approach for miniature multichannel spectrometer to enhance robustness for hand held field applications at a cost efficient price point.

  18. No programming required. Mobile PCs can help physicians work more efficiently, especially when the application is designed to fit the practice.

    PubMed

    Campbell, J

    2000-09-01

    The Jacobson Medical Group San Antonio Jacobson Medical Group (JMG) needed a way to effectively and efficiently coordinate referral information between their hospitalist physicians and specialists. JMG decided to replace paper-based binders with something more convenient and easily updated. The organization chose to implement a mobile solution that would provide its physicians with convenient access to a database of information via a hand-held computer. The hand-held solution provides physicians with full demographic profiles of primary care givers for each area where the group operates. The database includes multiple profiles based on different healthcare plans, along with details about preferred and authorized specialists. JMG adopted a user-friendly solution that the hospitalists and specialists would embrace and actually use.

  19. Hot air heat gun

    NASA Astrophysics Data System (ADS)

    Poston, Terry L.

    1989-10-01

    The invention relates generally to the art of self-contained heating devices and in particular to portable heating devices employing chemical reaction to produce heat. Currently, hand-held heat sources, capable of producing heat at a sufficiently high temperature to activate heat-shrink material, rely on either the combustion of flammable material or electrical power to provide energy for generating the required heat. An object of the present invention is to provide a portable device capable of providing sufficient heat to shrink heat-shrinkable tubing. A further object of the invention is to provide a non-flammable heat source suitable for use in the presence of explosive atmospheres. Still another object of the invention is to provide a portable hand-held device for generating heat which can be directed to a specific location on a work surface.

  20. SHIELDING AND DETECTOR RESPONSE CALCULATIONS PERTAINING TO CATEGORY 1 QUANTITIES OF PLUTONIUM AND HAND-HELD PLASTIC SCINTILLATORS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Couture, A.

    2013-06-07

    Nuclear facilities sometimes use hand-held plastic scintillator detectors to detect attempts to divert special nuclear material in situations where portal monitors are impractical. MCNP calculations have been performed to determine the neutron and gamma radiation field arising from a Category I quantity of weapons-grade plutonium in various shielding configurations. The shields considered were composed of combinations of lead and high-density polyethylene such that the mass of the plutonium plus shield was 22.7 kilograms. Monte-Carlo techniques were also used to determine the detector response to each of the shielding configurations. The detector response calculations were verified using field measurements of high-,more » medium-, and low- energy gamma-ray sources as well as a Cf-252 neutron source.« less

  1. Topographic analysis of the skull vibration-induced nystagmus test with piezoelectric accelerometers and force sensors.

    PubMed

    Dumas, Georges; Lion, Alexis; Perrin, Philippe; Ouedraogo, Evariste; Schmerber, Sébastien

    2016-03-23

    Vibration-induced nystagmus is elicited by skull or posterior cervical muscle stimulations in patients with vestibular diseases. Skull vibrations delivered by the skull vibration-induced nystagmus test are known to stimulate the inner ear structures directly. This study aimed to measure the vibration transfer at different cranium locations and posterior cervical regions to contribute toward stimulus topographic optimization (experiment 1) and to determine the force applied on the skull with a hand-held vibrator to study the test reproducibility and provide recommendations for good clinical practices (experiment 2). In experiment 1, a 100 Hz hand-held vibrator was applied on the skull (vertex, mastoids) and posterior cervical muscles in 11 healthy participants. Vibration transfer was measured by piezoelectric sensors. In experiment 2, the vibrator was applied 30 times by two experimenters with dominant and nondominant hands on a mannequin equipped to measure the force. Experiment 1 showed that after unilateral mastoid vibratory stimulation, the signal transfer was higher when recorded on the contralateral mastoid than on the vertex or posterior cervical muscles (P<0.001). No difference was observed between the different vibratory locations when vibration transfer was measured on vertex and posterior cervical muscles. Experiment 2 showed that the force applied to the mannequin varied according to the experimenters and the handedness, higher forces being observed with the most experienced experimenter and with the dominant hand (10.3 ± 1.0 and 7.8 ± 2.9 N, respectively). The variation ranged from 9.8 to 29.4% within the same experimenter. Bone transcranial vibration transfer is more efficient from one mastoid to the other mastoid than other anatomical sites. The mastoid is therefore the optimal site for skull vibration-induced nystagmus test in patients with unilateral vestibular lesions and enables a stronger stimulation of the healthy side. In clinical practice, the vibrator should be placed on the mastoid and should be held by the clinician's dominant hand.

  2. Limitations of Condensed Teaching Strategies to Develop Hand-Held Cardiac Ultrasonography Skills in Internal Medicine Residents.

    PubMed

    Wilkinson, Jeffrey S; Barake, Walid; Smith, Chris; Thakrar, Amar; Johri, Amer M

    2016-08-01

    Advances in ultrasonographic technology have allowed for hand-held cardiac ultrasonography (HHCU) units that fit into a physician's laboratory coat. Recently, studies to educate internal medicine residents have shown promise. The optimal duration and methodology for teaching HHCU skills has not been established. Over a 1-year period, internal medicine residents were recruited during their cardiology ward rotation into a single-centre nonblinded randomized trial. The 2 condensed teaching strategies were (1) a conventional ward-based program and (2) a technology-driven simulation-based strategy. Outcomes were evaluated by (1) an objective structured clinical examination (OSCE) to evaluate interpretation ability (assessing both type I and type II error rates) and (2) demonstration of HHCU skills graded by 2 level III echocardiographers. Twenty-four internal medicine residents were randomized. After teaching, the conventional teaching group had a significant absolute increase in the ability to make a singular correct diagnosis (20%; P < 0.001). In the technology arm, making a singular correct diagnosis increased 24% from baseline (P = 0.001). Interpretation skill was not significantly different between groups. The false-positive rate increased by an absolute 14% and 17% in the conventional and technology groups, respectively (P = 0.079 and P = 0.008). Our findings suggest that HHCU interpretation skills improve after either a conventional ward-based or a technology-driven approach. However, our study emphasizes the important limitations of both teaching programs, because we detected a trend toward an increase in the false-positive rate after both approaches. This suggests that a short duration of training may not be sufficient for HHCU to be performed in a safe manner. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  3. The Lunar Reconnaissance Orbiter Professional Development Workshop Series: Example of an Excellent Mechanism of Scientific Dissemination

    NASA Astrophysics Data System (ADS)

    Jones, A. P.; Hsu, B. C.; Bleacher, L.; Millham, R. A.

    2010-12-01

    The Lunar Reconnaissance Orbiter (LRO) Lunar Institute for Educators pilot workshop was held at NASA Goddard Space Flight Center in Greenbelt, MD in July of 2010. At this workshop, educators of grades 6-12 learned about lunar science, exploration, and how our understanding of the Moon has changed since the Apollo missions. The workshop exposed teachers to science results from recent lunar missions, particularly LRO, through presentations and discussions with lunar scientists. It allowed them to explore real LRO data, participate in hands-on lunar science activities, and learn how to incorporate these data and activities into their classrooms. Other workshop activities focused on mitigating student, and teacher, misconceptions about the Moon. As a result of the workshop, educators reported feeling a renewed excitement about the Moon, and more confidence in teaching lunar science to their students. Quarterly follow-up professional development sessions will monitor the progress of the workshop participants throughout the year, and provide additional support to the teachers, as needed. Evaluations from the 2010 pilot program are being used to improve LRO workshops as they expand contextually and geographically in the coming years. Ten workshops will be held across the United States in 2011 and 2012. Areas that have been underserved, with respect to NASA workshops, will be specifically targeted. Educator professional development workshops such as this one are an excellent mechanism for scientists to disseminate the latest discoveries from their missions and research to educators across the country and to get real data in the hands of students, further strengthening the students’ interest and understanding of science, technology, engineering, and math (STEM) content and careers. Making a model: educators construct topographic maps of Play-Doh volcanoes.

  4. Clinical utility of pH paper versus pH meter in the measurement of critical gastric pH in stress ulcer prophylaxis.

    PubMed

    Bradley, J S; Phillips, J O; Cavanaugh, J E; Metzler, M H

    1998-11-01

    To evaluate the clinical utility of measuring gastric pH with a pH meter vs. pH paper in critical care patients. Prospective comparison of gastric pH measurements, using both pH meter and pH paper. Surgical intensive care unit (ICU) at a rural Midwestern university medical center. Fifty-one patients who received therapy for prophylaxis of stress ulcers in the surgical ICU. Therapy for stress ulcer prophylaxis was monitored. The pH of 985 gastric samples, taken from 51 patients, was measured with both pH meter and pH paper. The pH meter and pH paper measures demonstrated a concordance correlation coefficient of .896. The mean difference between the two measures (pH paper - pH meter) was estimated to be between -0.4 and 1.4, suggesting a positive bias for the paper. The prevalence of events representing clinically relevant differences between the pH meter and pH paper in the measurement of the same gastric sample was calculated. The frequency with which each of the events occurred consecutively (or, in one case, two nearly consecutive events on the same day) was also calculated. Bias in a clinically relevant range was estimated. A set of "probability profiles" was constructed. A hand-held pH meter and pH paper are not interchangeable measures of gastric pH. The pH paper exhibits an appreciable positive bias compared with a hand-held pH meter in the clinically relevant range of 2 to 6. More research is needed to determine if that bias affects treatment outcomes. We recommend the use of a pH meter for patients who demonstrate pH readings of < or = 4, consecutive with readings of < or = 5.

  5. Prevalence of Hand-transmitted Vibration Exposure among Grass-cutting Workers using Objective and Subjective Measures

    NASA Astrophysics Data System (ADS)

    Azmir, N. A.; Yahya, M. N.

    2017-01-01

    Extended exposure to hand-transmitted vibration from vibrating machine is associated with an increased occurrence of symptoms of occupational disease related to hand disorder. The present case study is to determine the prevalence and correlation of significant subjective as well as objective variables that induce to hand arm vibration syndrome (HAVS) among hand-held grass-cutting workers in Malaysia. Thus, recommendations are made for grass-cutting workers and grass maintenance service management based on findings. A cross sectional study using adopted subjective Hand Arm Vibration Exposure Risk Assessment (HAVERA) questionnaire from Vibration Injury Network on hand disorder signs and symptoms was distributed to a sample of one hundred and sixty eight male workers from grass and turf maintenance industry that use vibrating machine as part of their work. For objective measure, hand-transmitted vibration measurement was collected on site during operation by the following ISO 5349-1, 2001. Two groups were identified in this research comprising of high exposure group and low-moderate exposure group. Workers also gave information about their personal identification, social history, workers’ health, occupational history and machine safety inspection. There was positive HAVS symptoms relationship between the low-moderate exposure group and high exposure group among hand-held grass-cutting workers. The prevalence ratio (PR) was considered high for experiencing white colour change at fingers and fingers go numb which are 3.63 (1.41 to 9.39) and 4.24 (2.18 to 8.27), respectively. The estimated daily vibration exposure, A(8) differs between 2.1 to 20.7 ms-2 for right hand while 2.7 to 29.1 ms-2 for left hand. The subjects claimed that the feel of numbness at left hand is much stronger compared to right hand. The results suggest that HAVS is diagnosed in Malaysia especially in agriculture sector. The A(8) indicates that the exposure value is more than exposure limit value which is 5 ms-2. Thus, control measure such as engineering and administrative control should be implemented to reduce the severity of hand-transmitted vibration hazard.

  6. Suitability of capillary blood obtained by a minimally invasive lancet technique to detect subclinical ketosis in dairy cows by using 3 different electronic hand-held devices.

    PubMed

    Kanz, P; Drillich, M; Klein-Jöbstl, D; Mair, B; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M

    2015-09-01

    The objective of this study was to evaluate the suitability of capillary blood obtained by a minimally invasive lancet technique to detect subclinical ketosis in 49 prepartum and 191 postpartum Holstein-Friesian cows using 3 different electronic hand-held devices [FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini), NovaVet (NOV, Nova Biomedical)]. The β-hydroxybutyrate (BHBA) concentration in serum harvested from coccygeal blood samples was analyzed in a laboratory and used as a reference value. Capillary samples were obtained from the skin of the exterior vulva by using 1 of 3 different lancets. In all samples, the concentration of BHBA was immediately analyzed with all 3 hand-held devices used in random order. All lancets used in the study were eligible for capillary blood collection but differed in the total number of incisions needed. Spearman correlation coefficients between the BHBA concentrations in capillary blood and the reference test were highly significant with 83% for the FSP, 73% for the NOV, and 63% for the GLX. Using capillary blood, the FSP overestimated the mean BHBA concentration compared with the reference test (+0.08 mmol/L), whereas the GLX and NOV underestimated the mean concentration (-0.07 and -0.01 mmol/L). When a BHBA concentration of 1.2 mmol/L in serum was used to define subclinical ketosis, the corresponding analyses of receiver operating characteristics resulted in optimized thresholds for capillary blood of 1.1 mmol/L for the NOV and GLX devices, and of 1.0 mmol/L for the FSP. Based on these thresholds, sensitivities (Se) and specificities (Sp) were 89 and 84% for the NOV, 80 and 89% for the GLX, and 100 and 76% for the FSP. Based on a serum BHBA concentration of 1.4 mmol/L, analyses of receiver operating characteristics resulted in optimized cut-offs of 1.4 mmol/L for the FSP (Se 100%, Sp 92%), 1.3 mmol/L for the NOV (Se 80%, Sp 95%), and 1.1 mmol/L (Se 90%, Sp 85%) for the GLX. Using these optimized thresholds for the specific hand-held meters, no significant differences between the devices in Se and Sp to detect subclinical ketosis in coccygeal blood were observed. Calculated test characteristics for analyzing capillary blood using the hand-held devices were numerically smaller compared with blood obtained from a coccygeal vessel, but overlapping confidence intervals indicate no statistical difference between the origin of the sample. Hence, this procedure seems to be suitable for ketosis monitoring in dairy cows, but further validation with more data from different farms is recommended. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. Hand-held optical fuel pin scanner

    DOEpatents

    Kirchner, T.L.; Powers, H.G.

    1980-12-07

    An optical scanner for indicia arranged in a focal plane perpendicular to an optical system including a rotatable dove prism. The dove prism transmits a rotating image to a stationary photodiode array.

  8. 46 CFR 197.420 - Operations manual.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... dive team. (b) The operations manual must be modified in writing when adaptation is required because of...) Hand-held power tools; (ii) Welding and burning equipment; and (iii) Explosives. specific diving mode...

  9. Equipment & New Products.

    ERIC Educational Resources Information Center

    Poitras, Adrian W., Ed.

    1979-01-01

    Reviews new science equipment and products for the laboratory. Includes hand-held calculators, fiberglass fume hoods, motorized microtomy, disposable mouse cages, and electric timers. Describes 11 products total. Provides manufacturer name, address, and price. (MA)

  10. Hand-held optical fuel pin scanner

    DOEpatents

    Kirchner, Tommy L.; Powers, Hurshal G.

    1987-01-01

    An optical scanner for indicia arranged in a focal plane perpendicular to an optical system including a rotatable dove prism. The dove prism transmits a rotating image to a stationary photodiode array.

  11. Transvaginal ultrasound (image)

    MedlinePlus

    Transvaginal ultrasound is a method of imaging the genital tract in females. A hand held probe is inserted directly ... vaginal cavity to scan the pelvic structures, while ultrasound pictures are viewed on a monitor. The test ...

  12. Light Sources and Lighting Circuits

    NASA Astrophysics Data System (ADS)

    Honda, Hisashi; Suwa, Takumi; Yasuda, Takeo; Ohtani, Yoshihiko; Maehara, Akiyoshi; Okada, Atsunori; Komatsu, Naoki; Mannami, Tomoaki

    According to the Machinery Statistics of the Ministry of Economy, Trade and Industry, the production of incandescent lamps in Japan in 2007 was 990 million units (90.0% of the previous year's total), in which the production of incandescent lamps for general lighting was 110 million units (90.0% of the previous year's total) and of tungsten-halogen lamps was 44 million units (96.6% of the previous year's total). The production of fluorescent lamps was 927 million units (93.9% of the previous year's total), in which general fluorescent lamps, excluding those for LCD back lighting, was 320 million units (87.2% of the previous year's total). Also, the production of HID lamps was 10 million units (101.5% of the previous year's total). On the other hand, when the numbers of sales are compared with the sales of the previous year, incandescent lamps for general use was 99.8%, tungsten-halogen lamps was 96.9%, fluorescent lamps was 95.9%, and HID lamps was 98.9%. Self-ballasted fluorescent lamps alone showed an increase in sales as strong as 29 million units, or 121.7% of the previous year's sales. It is considered that the switchover of incandescent lamps to HID lamps was promoted for energy conservation and carbon dioxide reduction with the problem of global warming in the background. In regard to exhibitions, Lighting Fair 2007 was held in Tokyo in March, and LIGHTFAIR INTERNATIONAL 2007 was held in New York in May. Regarding academic conferences, LS:11 (the 11th International Symposium on the Science & Technology of Light Sources) was held in Shanghai in May, and the First International Conference on White LEDs and Solid State Lighting was held in Tokyo in November. Both conferences suggested that there are strong needs and concerns now about energy conservation, saving natural resources, and restrictions of hazardous materials. In regard to incandescent lamps, the development of products aiming at higher efficacy, electric power savings, and longer life was advanced by means of using filler gas with a higher atomic weight. Regarding fluorescent lamps, studies and developments for longer operating life and improvement in the lumen maintenance factor for the straight-type and circular-type fluorescent lamps were actively pursued. Regarding self-ballasted fluorescent lamps, the main stream of development was aimed at reducing lamp size and increasing energy conservation, and the development of new products that took advantage of these features proceeded. In regard to LED light sources, basic research and product development, including new application development, were vigorously implemented. In basic research, studies were reported, not only on efficacy improvements through optimization of the LED chips, phosphor layers, and packaging technology, but also on photometry, colorimetry, and visual psychology. In the field of application, applications were studied for general lighting sources and also for a wide range of fields, such as automotive headlights and visible light communication. Also, many academic conferences and exhibitions were held domestically and overseas, and the high level of interest suggests high expectations for this next-generation light source. Regarding HID lamps, there was much activity in research and development and in the commercialization of the ceramic metal halide lamp product, and products were commercialized with features such as higher efficiency (130 lm/W) and higher color rendering properties (R9 ≥ 90). In the high-pressure sodium lamps, there were many study reports concerning plant growth and insect pest control using its low insect-attracting characteristics. With high-pressure mercury lamps, there were many reports on reducing lamp size and increasing intensity for use as a light source for projectors.

  13. Shipboard fisheries management terminals

    NASA Technical Reports Server (NTRS)

    Nagler, R. G.; Sager, E. V.

    1980-01-01

    The needs of the National Marine Fisheries Service (NMGS), National Weather Service, and the U.S. Coast Guard for locational, biological, and environmental data were assessed. The fisheries conservation zones and the yellowfin tuna jurisdiction of the NMFS operates observer programs on foreign and domestic fishing vessels. Data input terminal and data transfer and processing technology are reviewed to establish available capability. A matrix of implementation options is generated to identify the benefits of each option, and preliminary cost estimates are made. Recommendations are made for incremental application of available off the shelf hardware to obtain improved performance and benefits within a well bounded cost. Terminal recommendations are made for three interdependent shipboard units emphasizing: (1) the determination of location and fishing activity; (2) hand held data inputting and formatting in the fishing work areas; and (3) data manipulation, merging, and editing.

  14. Real-Time DNA Sequencing in the Antarctic Dry Valleys Using the Oxford Nanopore Sequencer

    PubMed Central

    Johnson, Sarah S.; Zaikova, Elena; Goerlitz, David S.; Bai, Yu; Tighe, Scott W.

    2017-01-01

    The ability to sequence DNA outside of the laboratory setting has enabled novel research questions to be addressed in the field in diverse areas, ranging from environmental microbiology to viral epidemics. Here, we demonstrate the application of offline DNA sequencing of environmental samples using a hand-held nanopore sequencer in a remote field location: the McMurdo Dry Valleys, Antarctica. Sequencing was performed using a MK1B MinION sequencer from Oxford Nanopore Technologies (ONT; Oxford, United Kingdom) that was equipped with software to operate without internet connectivity. One-direction (1D) genomic libraries were prepared using portable field techniques on DNA isolated from desiccated microbial mats. By adequately insulating the sequencer and laptop, it was possible to run the sequencing protocol for up to 2½ h under arduous conditions. PMID:28337073

  15. The Relationship Between Lower Extremily Strength and Shoulder Overuse Symptoms: A Model Based on Polio Survivors

    DTIC Science & Technology

    1998-01-01

    developed based on a questionnaire designed to measure habitual physical activity.9 The survey 124 included specific activities that might predispose...manual strength examination was then performed by a physical therapist using a hand- 149 held dynamometer (Empi Microfet2, St. Paul, MN). The physical ...subject pushed against the padded dynamometer force plate, 157 which the physical therapist held stationary. The peak force was measured in pounds, and

  16. Initial Usability Testing of a Hand-Held Electronic Logbook Prototype for the Human Research Facility

    NASA Technical Reports Server (NTRS)

    Berman, Andrea H.; Whitmore, Mihriban

    1996-01-01

    The Apple(R) Newton(TM) MessagePad 110 was flown aboard the KC-135 reduced gravity aircraft for microgravity usability testing. The Newton served as the initial hand-held electronic logbook prototype for the International Space Station (ISS) Human Research Facility (HRF). Subjects performed three different tasks with the Newton: (1) using the stylus to tap on different sections of the screen in order to launch an application and to select options within it; (2) using the stylus to write, and; (3) correcting handwriting recognition errors in a handwriting-intensive application. Subjects rated handwriting in microgravity 'Borderline' and had great difficulties finding a way in which to adequately restrain themselves at the lower body in order to have their hands free for the Newton. Handwriting recognition was rated 'Unacceptable,' but this issue is hardware-related and not unique to the microgravity environment. It is suggested that the restraint and handwriting issues are related and require further joint research with the current Handheld Electronic Logbook prototype: the Norand Pen*key Model #6300.

  17. Custodial Management in the Information Age.

    ERIC Educational Resources Information Center

    Harris, Jim, Sr.

    1999-01-01

    Explains how computerizing the custodial department can be achieved through bar coding, hand-held readers, and the appropriate software packages. Software programs that aid cleaning management, track assets, and manage stock are discussed. (GR)

  18. Distracted Driving

    MedlinePlus

    ... the Federal Motor Carrier Safety Administration and the Pipeline and Hazardous Materials Safety Administration banned all hand-held cell phone ... www.fmcsa.dot.gov/regulations/rulemaking/2010-23861 . Pipeline and Hazardous ... Safety Administration. Commercial Motor Vehicle Drivers: Restricting the ...

  19. Treating Sexual Problems for Men with Cancer

    MedlinePlus

    ... want to think about buying a hand-held electric vibrator. A vibrator can give very intense stimulation. ... Life Events College Relay For Life Donate a Car Ways to Give Memorial Giving Planned Giving Leadership ...

  20. Single sensor that outputs narrowband multispectral images

    PubMed Central

    Kong, Linghua; Yi, Dingrong; Sprigle, Stephen; Wang, Fengtao; Wang, Chao; Liu, Fuhan; Adibi, Ali; Tummala, Rao

    2010-01-01

    We report the work of developing a hand-held (or miniaturized), low-cost, stand-alone, real-time-operation, narrow bandwidth multispectral imaging device for the detection of early stage pressure ulcers. PMID:20210418

  1. 16 CFR 1120.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... hair dryer means an electrical appliance, intended to be held with one hand during use, which creates a flow of air over or through a self-contained heating element for the purpose of drying hair. (c...

  2. 16 CFR 1120.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... hair dryer means an electrical appliance, intended to be held with one hand during use, which creates a flow of air over or through a self-contained heating element for the purpose of drying hair. (c...

  3. Hand-held dynamic visual noise reduces naturally occurring food cravings and craving-related consumption.

    PubMed

    Kemps, Eva; Tiggemann, Marika

    2013-09-01

    This study demonstrated the applicability of the well-established laboratory task, dynamic visual noise, as a technique for reducing naturally occurring food cravings and subsequent food intake. Dynamic visual noise was delivered on a hand-held computer device. Its effects were assessed within the context of a diary study. Over a 4-week period, 48 undergraduate women recorded their food cravings and consumption. Following a 2-week baseline, half the participants watched the dynamic visual noise display whenever they experienced a food craving. Compared to a control group, these participants reported less intense cravings. They were also less likely to eat following a craving and consequently consumed fewer total calories following craving. These findings hold promise for curbing unwanted food cravings and craving-driven consumption in real-world settings. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. WebAlchemist: a Web transcoding system for mobile Web access in handheld devices

    NASA Astrophysics Data System (ADS)

    Whang, Yonghyun; Jung, Changwoo; Kim, Jihong; Chung, Sungkwon

    2001-11-01

    In this paper, we describe the design and implementation of WebAlchemist, a prototype web transcoding system, which automatically converts a given HTML page into a sequence of equivalent HTML pages that can be properly displayed on a hand-held device. The Web/Alchemist system is based on a set of HTML transcoding heuristics managed by the Transcoding Manager (TM) module. In order to tackle difficult-to-transcode pages such as ones with large or complex table structures, we have developed several new transcoding heuristics that extract partial semantics from syntactic information such as the table width, font size and cascading style sheet. Subjective evaluation results using popular HTML pages (such as the CNN home page) show that WebAlchemist generates readable, structure-preserving transcoded pages, which can be properly displayed on hand-held devices.

  5. Pilot study of a point-of-use decision support tool for cancer clinical trials eligibility.

    PubMed

    Breitfeld, P P; Weisburd, M; Overhage, J M; Sledge, G; Tierney, W M

    1999-01-01

    Many adults with cancer are not enrolled in clinical trials because caregivers do not have the time to match the patient's clinical findings with varying eligibility criteria associated with multiple trials for which the patient might be eligible. The authors developed a point-of-use portable decision support tool (DS-TRIEL) to automate this matching process. The support tool consists of a hand-held computer with a programmable relational database. A two-level hierarchic decision framework was used for the identification of eligible subjects for two open breast cancer clinical trials. The hand-held computer also provides protocol consent forms and schemas to further help the busy oncologist. This decision support tool and the decision framework on which it is based could be used for multiple trials and different cancer sites.

  6. Pilot Study of a Point-of-use Decision Support Tool for Cancer Clinical Trials Eligibility

    PubMed Central

    Breitfeld, Philip P.; Weisburd, Marina; Overhage, J. Marc; Sledge, George; Tierney, William M.

    1999-01-01

    Many adults with cancer are not enrolled in clinical trials because caregivers do not have the time to match the patient's clinical findings with varying eligibility criteria associated with multiple trials for which the patient might be eligible. The authors developed a point-of-use portable decision support tool (DS-TRIEL) to automate this matching process. The support tool consists of a hand-held computer with a programmable relational database. A two-level hierarchic decision framework was used for the identification of eligible subjects for two open breast cancer clinical trials. The hand-held computer also provides protocol consent forms and schemas to further help the busy oncologist. This decision support tool and the decision framework on which it is based could be used for multiple trials and different cancer sites. PMID:10579605

  7. System stability and calibrations for hand-held electromagnetic frequency domain instruments

    NASA Astrophysics Data System (ADS)

    Saksa, Pauli J.; Sorsa, Joona

    2017-05-01

    There are a few multiple-frequency domain electromagnetic induction (EMI) hand-held rigid boom systems available for shallow geophysical resistivity investigations. They basically measure secondary field real and imaginary components after the system calibrations. One multiple-frequency system, the EMP-400 Profiler from Geophysical Survey Systems Inc., was tested for system calibrations, stability and various effects present in normal measurements like height variation, tilting, signal stacking and time stability. Results indicated that in test conditions, repeatable high-accuracy imaginary component values can be recorded for near-surface frequency soundings. In test conditions, real components are also stable but vary strongly in normal surveying measurements. However, certain calibration issues related to the combination of user influence and measurement system height were recognised as an important factor in reducing for data errors and for further processing like static offset corrections.

  8. Metallic orthopaedic implants and airport metal detectors.

    PubMed

    Kamineni, S; Legge, S; Ware, H

    2002-01-01

    Airport security can detect in vivo metallic implants. We hypothesized that a soft tissue shield and fast transit through archway detectors would decrease implant detectability, whereas greater implant mass would increase detectability. Twelve patients with 8 orthopaedic implants in vivo and 60 trauma and arthroplasty implants in vitro were subjected to standard airport security measures at Stanstead Airport (British Airports Authority), including arch and standard and nonstandard hand-held detectors. Archway detectors failed to detect some implants; hand-held detectors detected almost all implants except an ankle arthroplasty. Positive archway detection was related to implant transit speed through the detection field. The implant mass consistently affected detection in stainless steel and titanium implants, and a 1-inch wax shield had no effect. Patients with metallic implants should prepare routinely with documentation of their implant before traveling through security ports.

  9. US-ROK Action Sheet 34: Safeguards Application of a Hand-held Mechanically Cooled Germanium Spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dreyer, J.; Burks, M.; Ham, Y.

    2015-10-20

    This report summarizes results of Action Sheet 34 - for the cooperative efforts on the field testing and evaluation of a high-resolution, hand-held, gamma-ray spectrometer, known as SPG (Spectroscopic Planar Germanium), for safeguards application such as short notice inspections, UF6 analysis, enrichment determination, and other potential applications. The Spectroscopic Planar Germanium (SPG) has been demonstrated IAEA Physical Inventory Verification (PIV) in South Korea. This field test was a success and the feedback provided by KINAC, IAEA, and national laboratory staff was used to direct efforts to improve the instrument this year. Key points in this report include measurement results frommore » PIV, analysis of spectra with commercially available Ortec U235 and PC-FRAM, and completion of tripod and tungsten collimator and integration of user feedback.« less

  10. Into the Wild: Neuroergonomic Differentiation of Hand-Held and Augmented Reality Wearable Displays during Outdoor Navigation with Functional Near Infrared Spectroscopy.

    PubMed

    McKendrick, Ryan; Parasuraman, Raja; Murtza, Rabia; Formwalt, Alice; Baccus, Wendy; Paczynski, Martin; Ayaz, Hasan

    2016-01-01

    Highly mobile computing devices promise to improve quality of life, productivity, and performance. Increased situation awareness and reduced mental workload are two potential means by which this can be accomplished. However, it is difficult to measure these concepts in the "wild". We employed ultra-portable battery operated and wireless functional near infrared spectroscopy (fNIRS) to non-invasively measure hemodynamic changes in the brain's Prefrontal cortex (PFC). Measurements were taken during navigation of a college campus with either a hand-held display, or an Augmented reality wearable display (ARWD). Hemodynamic measures were also paired with secondary tasks of visual perception and auditory working memory to provide behavioral assessment of situation awareness and mental workload. Navigating with an augmented reality wearable display produced the least workload during the auditory working memory task, and a trend for improved situation awareness in our measures of prefrontal hemodynamics. The hemodynamics associated with errors were also different between the two devices. Errors with an augmented reality wearable display were associated with increased prefrontal activity and the opposite was observed for the hand-held display. This suggests that the cognitive mechanisms underlying errors between the two devices differ. These findings show fNIRS is a valuable tool for assessing new technology in ecologically valid settings and that ARWDs offer benefits with regards to mental workload while navigating, and potentially superior situation awareness with improved display design.

  11. Body mass index, new modes of TV viewing and active video games.

    PubMed

    Falbe, J; Willett, W C; Rosner, B; Field, A E

    2017-10-01

    Recent technologies have changed screen time. TV can be viewed anywhere, anytime. Content can be collected via digital recorders and online streaming and viewed on smartphones. Video games are no longer strictly sedentary. We sought to assess the unknown relations between new modes of TV viewing - recorded, online, downloaded and on hand-held devices - and active video games with body mass index (BMI). Cross-sectional analysis of the 2011 wave of the Growing Up Today Study 2 cohort. We used gender-specific generalized estimating equations to examine screen time and BMI among 3071 women and 2050 men aged 16-24 years. Among women, each hour/day of online TV (0.47; confidence interval [CI]: 0.12, 0.82) and total non-broadcast TV (0.37; CI: 0.14, 0.61) was associated with higher BMI, as was watching ≥ 1/2 h week -1 of TV on hand-held devices (1.04; CI: 0.32-1.77). Active video games were associated with BMI among women, but not after restricting to those not trying to lose/maintain weight. Broadcast TV was associated with higher BMI (kg m -2 ) among women and men (P < 0.05). Among women, online TV, TV viewed on hand-held devices and the sum of non-broadcast TV time were associated with higher BMI. Broadcast TV was also associated with BMI in women and men. © 2016 World Obesity Federation.

  12. Into the Wild: Neuroergonomic Differentiation of Hand-Held and Augmented Reality Wearable Displays during Outdoor Navigation with Functional Near Infrared Spectroscopy

    PubMed Central

    McKendrick, Ryan; Parasuraman, Raja; Murtza, Rabia; Formwalt, Alice; Baccus, Wendy; Paczynski, Martin; Ayaz, Hasan

    2016-01-01

    Highly mobile computing devices promise to improve quality of life, productivity, and performance. Increased situation awareness and reduced mental workload are two potential means by which this can be accomplished. However, it is difficult to measure these concepts in the “wild”. We employed ultra-portable battery operated and wireless functional near infrared spectroscopy (fNIRS) to non-invasively measure hemodynamic changes in the brain’s Prefrontal cortex (PFC). Measurements were taken during navigation of a college campus with either a hand-held display, or an Augmented reality wearable display (ARWD). Hemodynamic measures were also paired with secondary tasks of visual perception and auditory working memory to provide behavioral assessment of situation awareness and mental workload. Navigating with an augmented reality wearable display produced the least workload during the auditory working memory task, and a trend for improved situation awareness in our measures of prefrontal hemodynamics. The hemodynamics associated with errors were also different between the two devices. Errors with an augmented reality wearable display were associated with increased prefrontal activity and the opposite was observed for the hand-held display. This suggests that the cognitive mechanisms underlying errors between the two devices differ. These findings show fNIRS is a valuable tool for assessing new technology in ecologically valid settings and that ARWDs offer benefits with regards to mental workload while navigating, and potentially superior situation awareness with improved display design. PMID:27242480

  13. CO2 laser myringotomy with a hand-held otoscope and fiber optic delivery system: animal experimentation and preclinical trials

    NASA Astrophysics Data System (ADS)

    DeRowe, Ari; Ophir, Dov; Finkelstein, Y.; Katzir, Abraham

    1993-07-01

    CO2 laser myringotomy has previously been proven effective in patients with serous otitis media for short term aeration of the middle ear. However, the system based on a microscope and a coaxially aligned laser is cumbersome and expensive. Also, conventional optical fibers do not transmit CO2 laser energy ((lambda) equals 10.6 micrometers ). We have developed a silver halide optical fiber of diameter 0.9 mm and lengths of several meters, with high transmission at 10.6 micrometers . Using a hand held otoscope coupled to a fiberoptic delivery system CO2 laser myringotomies were performed first in guinea pigs and then in humans. In the animal model the feasibility of the procedure was proven. Different irradiation parameters were studied and a `dose dependent' relationship was found between the total energy used and the duration of a patent myringotomy. This system was used to perform CO2 laser myringotomies under local anesthesia in five patients with serous otitis media and conductive hearing loss. None of the patients complained of discomfort and no scarring was noted. All patients had subjective and audiometric documentation of hearing improvement. The average duration of a patent myringotomy was 21 days. In two patients the effusion recurred. CO2 laser myringotomy utilizing a hand held otoscope coupled to an optical fiber capable of transmitting CO2 laser energy may prove simple and effective in the treatment of serous otitis media.

  14. Assessment of foot and ankle muscle strength using hand held dynamometry in patients with established rheumatoid arthritis.

    PubMed

    Carroll, Matthew; Joyce, William; Brenton-Rule, Angela; Dalbeth, Nicola; Rome, Keith

    2013-03-22

    The foot and ankle are frequently affected in patients with rheumatoid arthritis (RA). One of the negative consequences of RA on the physical function of patients is a decrease in muscle strength. However, little is known about foot and muscle strength in this population. The aim of the study was to evaluate significant differences in foot and ankle muscle strength between patients with established RA against age and sex-matched controls using hand-held dynamometry. The maximal muscle strength of ankle plantarflexion, dorsiflexion, eversion and inversion was assessed in 14 patients with RA, mean (SD) disease duration of 22 (14.1) years, and 20 age and sex-matched control participants using hand-held dynamometry. Significant differences were observed in muscle strength between the two groups in plantarflexion (p = 0.00), eversion (p = 0.04) and inversion (p = 0.01). No significant difference was found in dorsiflexion (p > 0.05). The patients with RA displayed a significantly lower plantarflexion-dorsiflexion ratio than the control participants (p = 0.03). The results from this study showed that the RA patients displayed a significant decrease in ankle dorsiflexion, eversion and inversion when compared to the non-RA control group suggesting that foot and ankle muscle strength may be affected by the pathological processes in RA. This study is a preliminary step for the measurement of muscle impairments within the RA population.

  15. Assessment of foot and ankle muscle strength using hand held dynamometry in patients with established rheumatoid arthritis

    PubMed Central

    2013-01-01

    Background The foot and ankle are frequently affected in patients with rheumatoid arthritis (RA). One of the negative consequences of RA on the physical function of patients is a decrease in muscle strength. However, little is known about foot and muscle strength in this population. The aim of the study was to evaluate significant differences in foot and ankle muscle strength between patients with established RA against age and sex-matched controls using hand-held dynamometry. Methods The maximal muscle strength of ankle plantarflexion, dorsiflexion, eversion and inversion was assessed in 14 patients with RA, mean (SD) disease duration of 22 (14.1) years, and 20 age and sex-matched control participants using hand-held dynamometry. Results Significant differences were observed in muscle strength between the two groups in plantarflexion (p = 0.00), eversion (p = 0.04) and inversion (p = 0.01). No significant difference was found in dorsiflexion (p > 0.05). The patients with RA displayed a significantly lower plantarflexion-dorsiflexion ratio than the control participants (p = 0.03). Conclusions The results from this study showed that the RA patients displayed a significant decrease in ankle dorsiflexion, eversion and inversion when compared to the non-RA control group suggesting that foot and ankle muscle strength may be affected by the pathological processes in RA. This study is a preliminary step for the measurement of muscle impairments within the RA population. PMID:23522448

  16. Reducing nurses'. Workload using a computerized nursing support system linked to the hospital information system.

    PubMed

    Ito, C; Satoh, I; Michiya, H; Kitayama, Y; Miyazaki, K; Ota, S; Satoh, H; Sakurai, T; Shirato, H; Miyasaka, K

    1997-01-01

    A computerised nursing support system (CNSS) linked to the hospital information system (HIS) was developed and has been in use for one year, in order to reduce the workload of nurses. CNSS consists of (1) a hand held computer for each nurse (2) desk-top computers in the nurses' station and doctors' rooms (3) a data server (4) an interface with the main hospital information system. Nurses enter vital signs, food intake and other information about the patients into the hand held computer at the bed-side. The information is then sent automatically to the CNSS data server, which also receives patients' details (prescribed medicines etc.) from the HIS. Nurses and doctors can see all the information on the desk-top and hand held computers. This system was introduced in May 1995 into a university hospital ward with 40 beds. A questionnaire was completed by 23 nurses before and after the introduction of CNSS. The mean time required to post vital data was significantly reduced from 121 seconds to 54 seconds (p < 0.01). After three months 30% of nurses felt CNSS had reduced their workload, while 30% felt it had complicated their work; after five months 70% noted a reduction and 0% reported that CNSS had made their work more complex. The study therefore concludes that the interface between a computerised nursing support system and the hospital information system reduced the workload of nurses.

  17. Finger tracking for hand-held device interface using profile-matching stereo vision

    NASA Astrophysics Data System (ADS)

    Chang, Yung-Ping; Lee, Dah-Jye; Moore, Jason; Desai, Alok; Tippetts, Beau

    2013-01-01

    Hundreds of millions of people use hand-held devices frequently and control them by touching the screen with their fingers. If this method of operation is being used by people who are driving, the probability of deaths and accidents occurring substantially increases. With a non-contact control interface, people do not need to touch the screen. As a result, people will not need to pay as much attention to their phones and thus drive more safely than they would otherwise. This interface can be achieved with real-time stereovision. A novel Intensity Profile Shape-Matching Algorithm is able to obtain 3-D information from a pair of stereo images in real time. While this algorithm does have a trade-off between accuracy and processing speed, the result of this algorithm proves the accuracy is sufficient for the practical use of recognizing human poses and finger movement tracking. By choosing an interval of disparity, an object at a certain distance range can be segmented. In other words, we detect the object by its distance to the cameras. The advantage of this profile shape-matching algorithm is that detection of correspondences relies on the shape of profile and not on intensity values, which are subjected to lighting variations. Based on the resulting 3-D information, the movement of fingers in space from a specific distance can be determined. Finger location and movement can then be analyzed for non-contact control of hand-held devices.

  18. Development of a high-speed VCSEL OCT system for real-time imaging of conscious patients larynx using a hand-held probe (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Rangarajan, Swathi; Chou, Li-Dek; Coughlan, Carolyn; Sharma, Giriraj; Wong, Brian J. F.; Ramalingam, Tirunelveli S.

    2016-02-01

    Fourier domain optical coherence tomography (FD-OCT) is a noninvasive imaging modality that has previously been used to image the human larynx. However, differences in anatomical geometry and short imaging range of conventional OCT limits its application in a clinical setting. In order to address this issue, we have developed a gradient-index (GRIN) lens rod-based hand-held probe in conjunction with a long imaging range 200 kHz Vertical-Cavity Surface Emitting Lasers (VCSEL) swept-source optical coherence tomography (SS-OCT) system for high speed real-time imaging of the human larynx in an office setting. This hand-held probe is designed to have a long and dynamically tunable working distance to accommodate the differences in anatomical geometry of human test subjects. A nominal working distance (~6 cm) of the probe is selected to have a lateral resolution <100 um within a depth of focus of 6.4 mm, which covers more than half of the 12 mm imaging range of the VCSEL laser. The maximum lateral scanning range of the probe at 6 cm working distance is approximately 8.4 mm, and imaging an area of 8.5 mm by 8.5 mm is accomplished within a second. Using the above system, we will demonstrate real-time cross-sectional OCT imaging of larynx during phonation in vivo in human and ex-vivo in pig vocal folds.

  19. Hand and Power Tools

    DTIC Science & Technology

    1998-01-01

    equipped with a constant- pressure switch or control: drills; tappers; fastener drivers; horizontal, vertical, and angle grinders with wheels more than...hand-held power tools must be equipped with either a positive “on-off” control switch, a constant pressure switch , or a “lock-on” control: disc sanders...percussion tools with no means of holding accessories securely, must be equipped with a constant- pressure switch that will shut off the power when the

  20. Study of Hand-Held Fire Extinguishers Aboard Civil Aviation Aircraft.

    DTIC Science & Technology

    1982-06-01

    or combustion products of the polymers used in aircraft construction have been found to include carbon monoxide (CO), carbon dioxide (CO ), hydrogen...toxicity rating, and ease of cleanup. The extinguishing agents used in this country for hand portable fire extinguishers are Carbon Dioxide, water, Halon...point where combustion stops." " Carbon dioxide fire extinguishing systems are useful within the limits of this standard in extinguishing fires in

  1. [Design of hand-held heart rate variability acquisition and analysis system].

    PubMed

    Li, Kaiyuan; Wang, Buqing; Wang, Weidong

    2012-07-01

    A design of handheld heart rate variability acquisition and analysis system is proposed. The system collects and stores the patient's ECG every five minutes through both hands touching on the electrodes, and then -uploads data to a PC through USB port. The system uses software written in LabVIEW to analyze heart rate variability parameters, The parameters calculated function is programmed and generated to components in Matlab.

  2. Astronaut Alan Bean reads data from book while holding teleprinter tape

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Astronaut Alan L. Bean, Skylab 3 commander, reads data from book in his right hand while holding teleprinter tape in his left hand, in the ward room of the Skylab space station's Orbital Workshop (OWS) crew quarters. This photograph was taken with a 35mm Nikon camera held by one of Bean's fellow crewmen during the 56.5 day second manned Skylab mission in Earth orbit.

  3. A simple handheld pupillometer for chromatic Flicker studies

    NASA Astrophysics Data System (ADS)

    Bernabei, M.; Tinarelli, R.; Peretto, L.; Rovati, L.

    2014-02-01

    A portable pupillometer has been developed which is capable of performing accurate measurements of the pupil diameter during chromatic flicker stimulations. The handheld measuring system records the near-infrared image of the pupil at the rate of 25 fps and simultaneously stimulates the eye using a diffused flicker light generated by light emitting diodes (LEDs). Intensity, frequency and chromatic coordinates of the stimulus can be easily adjusted using a user-friendly graphical interface. Thanks to a chromatic monitoring of the stimulus close to the plane of the eye, photopically matched conditions can be easily achieved. The pupil diameter/area can be measured during flickering stimuli that are generated with frequency in a range of 0.1-20 Hz. The electronic unit, properly connected to the personal computer through a USB port, drives the optical unit, which can be easily held in a hand. The software interface controlling the system was developed in LabVIEW. This paper describes the instrument optical setup, front-end electronics and data processing. Moreover preliminary results obtained on a voluntary are reported.

  4. Lightweight, High-Current Welding Gun

    NASA Technical Reports Server (NTRS)

    Starck, Thomas F.; Brennan, Andrew D.

    1989-01-01

    Lighweight resistance-welding, hand-held gun supplies alternating or direct current over range of 600 to 4,000 A and applies forces from 40 to 60 lb during welding. Used to weld metal sheets in multilayered stacks.

  5. School age test or procedure preparation

    MedlinePlus

    ... your child with books, bubbles, games, hand-held video games, or other activities. PLAY PREPARATION Children often avoid responding when asked direct questions about their feelings. Some ... from videos that show children of the same age explaining, ...

  6. Adolescent test or procedure preparation

    MedlinePlus

    ... someone else) during the procedure Playing hand-held video games Using guided imagery Trying other distractions, such as listening to music through headphones, if allowed When possible, let ... from videos that show adolescents of the same age explaining ...

  7. 16 CFR § 1120.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... hair dryer means an electrical appliance, intended to be held with one hand during use, which creates a flow of air over or through a self-contained heating element for the purpose of drying hair. (c...

  8. Fetal echocardiography

    MedlinePlus

    ... based gel on your belly. A hand-held probe is moved over the area. The probe sends out sound waves, which bounce off the ... screen. In a transvaginal ultrasound, a much smaller probe is placed into the vagina. A transvaginal ultrasound ...

  9. Students and NASA Study Aerosols over Baltimore

    NASA Image and Video Library

    2003-06-11

    During Spring 2003, students, teachers, and scientists worked side-by-side, measuring the properties of aerosols fine particulate matter suspended in the air over Baltimore, Maryland using hand-held instruments shown here by NASA Terra spacecraft.

  10. Doppler Ultrasound: What Is It Used for?

    MedlinePlus

    ... During a Doppler ultrasound, a technician trained in ultrasound imaging (sonographer) presses a small hand-held device (transducer), ... neurologic-disorders/neurologic-tests-and-procedures/other-neurologic-imaging-studies. Accessed Oct. 18, 2016. ... . Mayo Clinic Footer Legal ...

  11. Development of hand-held thermographic inspection technologies.

    DOT National Transportation Integrated Search

    2009-08-01

    Subsurface deterioration in concrete structures presents a significant challenge for inspection and maintenance engineers. Cracking, delaminations and spalling that can occur as a result of corrosion of embedded reinforcing steel can lead to pot hole...

  12. 47 CFR 15.519 - Technical requirements for hand held UWB systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... information to an associated receiver. The UWB intentional radiator shall cease transmission within 10 seconds... received. An acknowledgment of reception must continue to be received by the UWB intentional radiator at...

  13. Hand involvement in children with Charcot-Marie-Tooth disease type 1A.

    PubMed

    Burns, Joshua; Bray, Paula; Cross, Lauren A; North, Kathryn N; Ryan, Monique M; Ouvrier, Robert A

    2008-12-01

    Charcot-Marie-Tooth disease type 1A (CMT1A), a demyelinating neuropathy characterised by progressive length-dependent muscle weakness and atrophy, is thought to affect the foot and leg first followed some time later by hand weakness and dysfunction. We aimed to characterise hand strength, function and disease-related symptoms in children with CMT1A. Intrinsic and extrinsic hand strength was measured by hand-held dynamometry, function by nine-hole peg test, and disease-related symptoms by interview and examination in 84 affected children aged 2-16 years. Hand weakness and dysfunction was present from the earliest stages of the disease. While hand strength and function measures tended to increase with age throughout childhood, at no point did they reach normal values. Day-to-day hand problems such as poor handwriting, weakness, pain and sensory symptoms also worsened with age. The hand is affected at all ages in children with CMT1A, but may be under-recognised in its early stages, potentially delaying therapy.

  14. An analysis of the input-output properties of neuroprosthetic hand grasps.

    PubMed

    Memberg, W D; Crago, P E

    2000-01-01

    We measured the input-output properties of the hand grasps of 14 individuals with tetraplegia at the C5/C6 level who had received an implanted upper limb neuroprosthesis. The data provide a quantitative description of grasp-opening and grasp-force control with neuroprosthetic hand grasp systems. Static properties were estimated by slowly ramping the command (input) from 0 to 100%. A hand-held sensor monitored the outputs: grasp force and grasp opening. Trials were performed at different wrist positions, with two different-sized objects being held, and with both grasp modes (lateral and palmar grasps). Larger forces were produced when grasping larger objects, and greater opening was achieved with the wrist in flexion. Although active grasp force increased with wrist extension, it was not significant statistically. Lateral grasp produced larger forces than the palmar grasp. The command range can be divided into a portion that controls grasp opening and a portion that controls grasp force. The portion controlling force increased with spacer size, but did not depend significantly on grasp mode or wrist position. The force-command relationships were more linear than the position-command relationships. Grasp opening decreased significantly over a one-year period, while no significant change in grasp force was observed. These quantitative descriptions of neuroprosthetic hand grasps under varying conditions provide useful information about output capabilities that can be used to gauge the effectiveness of different control schemes and to design future control systems.

  15. Dose-response relation between exposure to two types of hand-arm vibration and sensorineural perception of vibration.

    PubMed

    Virokannas, H

    1995-05-01

    31 railway workers and 32 lumberjacks were examined to compare the dose-response relation between the exposure to two types of hand-arm vibration and the sensory disturbances in peripheral nerves as evaluated by the vibration perception thresholds (VPTs). Clinical examinations were carried out that included measurements of the VPTs, and electroneuromyography (ENMG), and an inquiry to confirm the use of vibrating tools. Diseases of the central nervous system and neuropathies were checked by inquiry and a clinical examination, diabetes was excluded by a blood sample analysis, and the subjects with carpal tunnel syndrome confirmed with ENMG were excluded from the study. Lifetime use of hand held tamping machines (railway workers) and chain saws (lumberjacks) had a significant correlation with the VPTs at frequencies from 32 to 500 Hz. The increase of the VPTs (250 Hz) in relation to use of vibrating tools was 1.8-fold higher on average in the whole group and 2.3-fold higher in the young (< 45) railway workers who had used hand held tamping machines, than in the corresponding groups of lumberjacks, who had used chain saws, whereas the frequency weighted acceleration of vibration in tamping machines was fourfold. There was a significant dose-response relation between the exposure to hand-arm vibration and the VPTs. The VPTs as a function of the frequency weighted acceleration of vibration and the exposure to vibration gave promising results for assessment of the risk of damage to sensory nerves induced by vibration.

  16. Explaining direct care resource use of nursing home residents: findings from time studies in four states.

    PubMed

    Arling, Greg; Kane, Robert L; Mueller, Christine; Lewis, Teresa

    2007-04-01

    To explain variation in direct care resource use (RU) of nursing home residents based on the Resource Utilization Groups III (RUG-III) classification system and other resident- and unit-level explanatory variables. Primary data were collected on 5,314 nursing home residents in 156 nursing units in 105 facilities from four states (CO, IN, MN, MS) from 1998 to 2004. Study Design. Nurses and other direct care staff recorded resident-specific and other time caring for all residents on sampled nursing units. Care time was linked to resident data from the Minimum Data Set assessment instrument. Major variables were: RUG-III group (34-group), other health and functional conditions, licensed and other professional minutes per day, unlicensed minutes per day, and direct care RU (wage-weighted minutes). Resident- and unit-level relationships were examined through hierarchical linear modeling. Time study data were recorded with hand-held computers, verified for accuracy by project staff at the data collection sites and then merged into resident and unit-level data sets. Resident care time and RU varied between and within nursing units. RUG-III group was related to RU; variables such as length of stay and unit percentage of high acuity residents also were significantly related. Case-mix indices (CMIs) constructed from study data displayed much less variation across RUG-III groups than CMIs from earlier time studies. Results from earlier time studies may not be representative of care patterns of Medicaid and private pay residents. New RUG-III CMIs should be developed to better reflect the relative costs of caring for these residents.

  17. Moment of Inertia: Psychophysical Study of an Overlooked Sensation.

    ERIC Educational Resources Information Center

    Science, 1979

    1979-01-01

    This article describes the distribution of mass in a hand-held object as a fundamental but unrecognized contributor to the sensation one receives from the object. Experiments producing fractions for human sensitivity are given. (SA)

  18. Magnet-wire wrapping tool for integrated circuits

    NASA Technical Reports Server (NTRS)

    Takahashi, T. H.

    1972-01-01

    Wire-dispensing tool which resembles mechanical pencil is used to wrap magnet wire around integrated circuit terminals uniformly and securely without damaging insulative coating on wire. Tool is hand-held and easily manipulated to execute wire wrapping movements.

  19. Hand-held instrument should relieve hematoma pressure

    NASA Technical Reports Server (NTRS)

    Raggio, L. J.; Robertson, T. L.

    1967-01-01

    Portable instrument relieves hematomas beneath fingernails and toenails without surgery. This device simplifies the operative procedure with an instant variable heating tip, adjustable depth settings and interchangeable tip sizes for cauterizing small areas and relieving pressurized clots.

  20. WISE Design for Knowledge Integration.

    ERIC Educational Resources Information Center

    Linn, Marcia C.; Clark, Douglas; Slotta, James D.

    2003-01-01

    Examines the implementation of Web-based Inquiry Science Environment (WISE), which can incorporate modeling tools and hand-held devices. Describes WISE design team practices, features of the WISE learning environment, and patterns of feature use in WISE library projects. (SOE)

  1. Measuring Room Area or Volume Electronically

    NASA Technical Reports Server (NTRS)

    Kavaya, M. J.

    1987-01-01

    Area- and volume-measuring instrument hand-held or mounted on tripod. Instrument rapidly measures distances to walls, ceiling, or floor at many viewing angles and automatically computes area or volume of room. Results obtained rapidly with minimal effort.

  2. 16 CFR 1507.7 - Handles and spikes.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... FIREWORKS DEVICES § 1507.7 Handles and spikes. (a) Fireworks devices which are intended to be hand-held and...) Spikes provided with fireworks devices shall protrude at least 2 inches from the base of the device and...

  3. Application of computer image enhancement techniques to shuttle hand-held photography

    NASA Technical Reports Server (NTRS)

    David, B. E.

    1986-01-01

    With the advent of frequent Space Transportation System Shuttle missions, photography from hyperaltitudes stands to become an accessible and convenient resource for scientists and environmental managers. As satellite products (such as LANDSAT) continue to spiral in costs, all but the most affluent consumer is finding Earth imagery from space to be more and more unavailable. Therefore, the potential for Shuttle photography to serve a wide variety of users is increasing. However, despite the popularity of photos from space as public relations tools and report illustrations, little work has been performed to prove their scientific worth beyond that as basic mapping bases. It is the hypothesis of this project that hand-held Earth photography from the Space Shuttle has potentially high scientific merit and that primary data can be extracted. In effect, Shuttle photography should be considered a major remote sensing information resource.

  4. The Complimentary Role of Methoxy-Isobutyl-Isonitrile and Hand-Held Gamma Probe in Adamantinoma

    PubMed Central

    Maharaj, Masha; Korowlay, Nisaar; Ellmann, Prof

    2016-01-01

    Adamantinoma is a rare locally aggressive osteolytic tumor that is found 90% of the time in the diaphysis of the tibia with the remaining lesions found in the fibula and long tubular bones. A case of adamantinoma of the tibia is presented. The added value of nuclear medicine investigations in the workup of this patient is described. A three-phase whole body 99mTc-methylene diphosphonate bone and a whole body 99mTc-methoxy-isobutyl-isonitrile scans were complimentary in the demarcation of viable bone tumor and the assessment of the remainder of the bone and soft tissue to exclude other sites. Intra-operative assistance with a hand-held gamma probe, guided the biopsy of the most metabolically active tumor tissue. Histology revealed a biphasic tumor composed of epithelial and fibrous components, in keeping with an adamantinoma. PMID:26912979

  5. Beyond textbook illustrations: Hand-held models of ordered DNA and protein structures as 3D supplements to enhance student learning of helical biopolymers.

    PubMed

    Jittivadhna, Karnyupha; Ruenwongsa, Pintip; Panijpan, Bhinyo

    2010-11-01

    Textbook illustrations of 3D biopolymers on printed paper, regardless of how detailed and colorful, suffer from its two-dimensionality. For beginners, computer screen display of skeletal models of biopolymers and their animation usually does not provide the at-a-glance 3D perception and details, which can be done by good hand-held models. Here, we report a study on how our students learned more from using our ordered DNA and protein models assembled from colored computer-printouts on transparency film sheets that have useful structural details. Our models (reported in BAMBED 2009), having certain distinguished features, helped our students to grasp various aspects of these biopolymers that they usually find difficult. Quantitative and qualitative learning data from this study are reported. Copyright © 2010 International Union of Biochemistry and Molecular Biology, Inc.

  6. Hand-held photomicroscope

    NASA Technical Reports Server (NTRS)

    Zabower, H. R. (Inventor)

    1973-01-01

    A small, lightweight, compact, hand-held photomicroscope provides simultaneous viewing and photographing, with adjustable specimen illumination and exchangeable camera format. The novel photomicroscope comprises a main housing having a top plate, bottom plate, and side walls. The objective lens is mounted on the top plate in an inverted manner relative to the normal type of mounting. The specimen holder has an adjusting mechanism for adjustably moving the specimen vertically along an axis extending through the objective lens as well as transverse of the axis. The lens system serves to split the beam of light into two paths, one to the eyepiece and the other to a camera mounting. A light source is mounted on the top plate and directs light onto the specimen. A rheostat device is mounted on the top plate and coupled to the power supply for the light source so that the intensity of the light may be varied.

  7. Biolistic transfection of neuronal cultures using a hand-held gene gun

    PubMed Central

    O'Brien, John A; Lummis, Sarah C R

    2009-01-01

    Biolistic transfection is a technique in which subcellular-sized particles coated with DNA are accelerated to high velocity to propel them into cells. This method is applicable to tissues, cells and organelles, and can be used for both in vitro and in vivo transformations; with the right equipment, it is simple, rapid and efficient. Here we provide a detailed protocol for biolistic transfection of plasmids into cultured human embryonic kidney (HEK) 293 cells and organotypic brain slices using a hand-held gene gun. There are three major steps: (i) coating microcarriers with DNA, (ii) transferring the microcarriers into a cartridge to make a ‘bullet’, and (iii) firing the DNA-coated microcarriers into cells using a pulse of helium gas. The method can be readily adapted to other cell types and tissues. The protocol can be completed in 1–2 h. PMID:17406333

  8. Raman spectroscopy compared against traditional predictors of shear force in lamb m. longissimus lumborum.

    PubMed

    Fowler, Stephanie M; Schmidt, Heinar; van de Ven, Remy; Wynn, Peter; Hopkins, David L

    2014-12-01

    A Raman spectroscopic hand held device was used to predict shear force (SF) of 80 fresh lamb m. longissimus lumborum (LL) at 1 and 5days post mortem (PM). Traditional predictors of SF including sarcomere length (SL), particle size (PS), cooking loss (CL), percentage myofibrillar breaks and pH were also measured. SF values were regressed against Raman spectra using partial least squares regression and against the traditional predictors using linear regression. The best prediction of shear force values used spectra at 1day PM to predict shear force at 1day which gave a root mean square error of prediction (RMSEP) of 13.6 (Null=14.0) and the R(2) between observed and cross validated predicted values was 0.06 (R(2)cv). Overall, for fresh LL, the predictability SF, by either the Raman hand held probe or traditional predictors was low. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Comparative Geometrical Investigations of Hand-Held Scanning Systems

    NASA Astrophysics Data System (ADS)

    Kersten, T. P.; Przybilla, H.-J.; Lindstaedt, M.; Tschirschwitz, F.; Misgaiski-Hass, M.

    2016-06-01

    An increasing number of hand-held scanning systems by different manufacturers are becoming available on the market. However, their geometrical performance is little-known to many users. Therefore the Laboratory for Photogrammetry & Laser Scanning of the HafenCity University Hamburg has carried out geometrical accuracy tests with the following systems in co-operation with the Bochum University of Applied Sciences (Laboratory for Photogrammetry) as well as the Humboldt University in Berlin (Institute for Computer Science): DOTProduct DPI-7, Artec Spider, Mantis Vision F5 SR, Kinect v1 + v2, Structure Sensor and Google's Project Tango. In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data were acquired by measurement with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M). The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  10. Occupational risk identification using hand-held or laptop computers.

    PubMed

    Naumanen, Paula; Savolainen, Heikki; Liesivuori, Jyrki

    2008-01-01

    This paper describes the Work Environment Profile (WEP) program and its use in risk identification by computer. It is installed into a hand-held computer or a laptop to be used in risk identification during work site visits. A 5-category system is used to describe the identified risks in 7 groups, i.e., accidents, biological and physical hazards, ergonomic and psychosocial load, chemicals, and information technology hazards. Each group contains several qualifying factors. These 5 categories are colour-coded at this stage to aid with visualization. Risk identification produces visual summary images the interpretation of which is facilitated by colours. The WEP program is a tool for risk assessment which is easy to learn and to use both by experts and nonprofessionals. It is especially well adapted to be used both in small and in larger enterprises. Considerable time is saved as no paper notes are needed.

  11. Left-hand dominance in children: Prevalence and maternal stereotypes in a South-east Nigerian city.

    PubMed

    Uwaezuoke, Samuel N; Eke, Christopher B; Nwobi, Emmanuel A

    2015-01-01

    The objectives of the study are to estimate the prevalence of left-hand dominance among children of selected mothers in an urban city and to determine the mothers' stereotypes about left-handedness. A cross-sectional study of mothers (N = 222) selected by systematic random sampling was done. The mothers were interviewed with structured questionnaires. Data were analyzed with appropriate descriptive statistics on SPSS. The estimated prevalence of left-hand dominance in their children was 7.52%. A left-handed mother was more likely to have a left-handed child. A substantial number of the mothers held negative stereotypes about left-hand dominance and showed a good knowledge about other types of handedness with a significant difference in the responses between right-handers and left-handers. The prevalence of left-hand dominance in their children supports previous reports which show that left-handedness usually occurs in less than 10% of the population. The mothers' negative stereotypes signify the likelihood of stigmatizing the children with this hand dominance.

  12. Use of a SPAD-502 meter to measure leaf chlorophyll concentration in Arabidopsis thaliana.

    PubMed

    Ling, Qihua; Huang, Weihua; Jarvis, Paul

    2011-02-01

    The SPAD-502 meter is a hand-held device that is widely used for the rapid, accurate and non-destructive measurement of leaf chlorophyll concentrations. It has been employed extensively in both research and agricultural applications, with a range of different plant species. However, its utility has not been fully exploited in relation to the most intensively studied model organism for plant science research, Arabidopsis thaliana. Measurements with the SPAD-502 meter produce relative SPAD meter values that are proportional to the amount of chlorophyll present in the leaf. In order to convert these values into absolute units of chlorophyll concentration, calibration curves must be derived and utilized. Here, we present calibration equations for Arabidopsis that can be used to convert SPAD values into total chlorophyll per unit leaf area (nmol/cm(2); R(2) = 0.9960) or per unit fresh weight of leaf tissue (nmol/mg; R(2) = 0.9809). These relationships were derived using a series of Arabidopsis chloroplast biogenesis mutants that exhibit chlorophyll deficiencies of varying severity, and were verified by the subsequent analysis of senescent or light-stressed leaves. Our results revealed that the converted SPAD values differ from photometric measurements of solvent-extracted chlorophyll by just ~6% on average.

  13. Additional Haptic Information Provided by Anchors Reduces Postural Sway in Young Adults Less Than Does Light Touch

    PubMed Central

    Moraes, Renato; Bedo, Bruno L. S.; Santos, Luciana O.; Batistela, Rosangela A.; Santiago, Paulo R. P.; Mauerberg-deCastro, Eliane

    2018-01-01

    This study investigated the effect of adding haptic information to the control of posture, as well as comparing the effect of both the “light touch” (LT) and “anchor system” (AS) paradigms on postural sway. Additionally, it compared the effect of location and number of points of contact to the control of posture in young adults. The location consisted of using the anchors tied to the finger and held by the hands, and, for LT, the fingertip. For the number of points of contact, participants used two hands, and then separately the dominant hand, and the non-dominant hand, for both anchor and LT paradigms. Participants stood upright with feet-together and in tandem position while performing tasks that combined the use of anchors and LT, points of contact (hand grip and finger), and number of points of contact (two hands and one hand). In this study, the anchors consist of holding in each hand a flexible cable with the other end attached to the ground. The LT consists of slightly touching a rigid surface with the tip of the index finger. The results showed, first, that the anchors improved postural control less than did the LT. Second, they revealed that holding the anchors with the hands or with them tied to the fingertip resulted in a similar reduction in postural sway only in the tandem position. For the feet-together position, the anchors tied to the fingertip were ineffective. Similarly, the use of one or two hands did not affect the contribution of the anchors. However, using two hands in the LT condition was more effective than was one hand. Third, our results showed the presence of a temporal delay between force and center-of-pressure (COP) for the anchors, only in the AP direction with feet-together. In conclusion, overall, the anchors were less effective in reducing postural sway than was the LT. The anchors attached to fingertips were as effective as the hand-held anchors in the tandem position, yet ineffective during foot-together standing. Force-COP timing explains reduced postural sway with LT but not for the anchor; hence, exploratory and supra-postural components may be involved. PMID:29922122

  14. Hand-held portable desorption atmospheric pressure chemical ionization ion source for in situ analysis of nitroaromatic explosives.

    PubMed

    Jjunju, Fred P M; Maher, Simon; Li, Anyin; Syed, Sarfaraz U; Smith, Barry; Heeren, Ron M A; Taylor, Stephen; Cooks, R Graham

    2015-10-06

    A novel, lightweight (0.6 kg), solvent- and gas-cylinder-free, hand-held ion source based on desorption atmospheric pressure chemical ionization has been developed and deployed for the analysis of nitroaromatic explosives on surfaces in open air, offering portability for in-field analysis. A small, inexpensive, rechargeable lithium polymer battery was used to power the custom-designed circuitry within the device, which generates up to ±5 kV dc voltage to ignite a corona discharge plasma in air for up to 12 h of continuous operation, and allowing positive- and negative-ion mass spectrometry. The generated plasma is pneumatically transported to the surface to be interrogated by ambient air at a rate of 1-3.5 L/min, compressed using a small on-board diaphragm pump. The plasma source allows liquid or solid samples to be examined almost instantaneously without any sample preparation in the open environment. The advantages of low carrier gas and low power consumption (<6 W), as well as zero solvent usage, have aided in developing the field-ready, hand-held device for trigger-based, "near-real-time" sampling/ionization. Individual nitroaromatic explosives (such as 2,4,6-trinitrotoluene) can be easily detected in amounts as low as 5.8 pg with a linear dynamic range of at least 10 (10-100 pg), a relative standard deviation of ca. 7%, and an R(2) value of 0.9986. Direct detection of several nitroaromatic compounds in a complex mixture without prior sample preparation is demonstrated, and their identities are confirmed by tandem mass spectrometry fragmentation patterns.

  15. Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer.

    PubMed

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-01-01

    To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.

  16. Development of a miniature autofluorescence device for the early diagnosis of squamous cell carcinoma

    NASA Astrophysics Data System (ADS)

    Patil, Ajeetkumar; Rao K., Swati; V. K., Unnikrishnan; Pai, Keerthilatha M.; Kartha, V. B.; Chidangil, Santhosh

    2017-07-01

    Autofluorescence spectroscopy offer noninvasive and promising tools for the detection of alternations biochemical compositions of tissues and cells, in presence of disease. They have the added advantage of being highly objective due to the fact that diagnostic evaluation is by statistical methods, eliminating errors from lack of experience, fatigue factor, and subjectivity of visual perceptions. The present research work involves in designing and assembling of a low cost, miniature oral cancer screening device with for routine clinical applications. A miniature system was designed and assembled with much smaller and cost-effective components like compact light source and miniature spectrometer, in a hand-held unit configuration. The performance of the system was evaluated using animal -mouse- SCC model. The current system can be used in handheld operation, which makes it very useful for many applications like, screening of squamous cell carcinoma susceptible population.

  17. Fiber optically guided CO2 laser myringotomy through an otoscope: animal experimentation

    NASA Astrophysics Data System (ADS)

    DeRowe, Ari; Ophir, Dov; Katzir, Abraham

    1992-08-01

    We have developed an otoscope which contains an optical fiber capable of transmitting CO2 laser energy. Such a hand-held unit may prove useful in the treatment of acute otitis media and otitis media with effusion. We used crystalline fibers (0.9 mm diameter) capable of transmitting CO2 laser energy. Four guinea pigs were anaesthetized. In one ear a laser myringotomy was performed using 7.5 watts for 0.1 seconds. The diameter of the myringotomy was 1.5 mm. In the other ear a similar conventional myringotomy was performed. After three weeks three laser and three conventional myringotomies were closed. On the average conventional myringotomies closed 50% sooner than laser myringotomies. Temporal bones from three guinea pigs were removed and sectioned according to accepted methods. No histological differences were found between ears. This experiment has proven the feasibility of using an otoscope for fiberoptically guided CO2 laser myringotomy.

  18. STS-56 MS1 Foale and MS2 Cockrell on aft flight deck of Discovery, OV-103

    NASA Technical Reports Server (NTRS)

    1993-01-01

    STS-56 Mission Specialist 1 (MS1) Michael Foale (left) and MS2 Kenneth D. Cockrell pose on aft flight deck of Discovery, Orbiter Vehicle (OV) 103, for this in-cabin electronic still camera (ESC) photograph. The two crewmembers are positioned in front of the onorbit station with a beam of sunlight shining through overhead window W8. The cable on the bottom right is part of the Hand-held, Earth-oriented, Real-time, Cooperative, User-friendly, Location-targeting and Environmental System (HERCULES), connecting the HERCULES Attitude Processor (HAP) to the Inertial Measurement Unit (IMU). In-cabin shots with the camera are for test purposes only. HERCULES is a device that makes it simple for Shuttle crewmembers to take pictures of Earth as they merely point and shoot any interesting feature, whose latitude and longitude are automatically determined in real time. Digital file name is ESC01008.TGA.

  19. RME 1323, AERCam/Sprint held by Lindsey in the middeck

    NASA Image and Video Library

    1998-01-14

    STS087-371-013 (19 November - 5 December 1997) --- On the Space Shuttle Columbia's mid-deck, astronaut Steven W. Lindsey proves that the Autonomous Extravehicular Activity Robotic Camera/Sprint (AERCam/Sprint) experiment is in fact bigger than a soccer ball, to which it is often erroneously compared for dimensional frame of reference, as he allows the Sprint to float near him. The AERCam is a prototype free-flying television camera that could be used for remote inspections of the exterior of the International Space Station (ISS). Later, astronauts Winston E. Scott and Takao Doi took the experiment outside for a brief test during the mission's second Extravehicular Activity (EVA). Lindsey, pilot, is standing with his back to the galley and his left hand on the microgravity glovebox, used extensively during the mission to support the United States Microgravity Payload (USMP-4) mission.

  20. Miniature Heat Pipes

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Small Business Innovation Research contracts from Goddard Space Flight Center to Thermacore Inc. have fostered the company work on devices tagged "heat pipes" for space application. To control the extreme temperature ranges in space, heat pipes are important to spacecraft. The problem was to maintain an 8-watt central processing unit (CPU) at less than 90 C in a notebook computer using no power, with very little space available and without using forced convection. Thermacore's answer was in the design of a powder metal wick that transfers CPU heat from a tightly confined spot to an area near available air flow. The heat pipe technology permits a notebook computer to be operated in any position without loss of performance. Miniature heat pipe technology has successfully been applied, such as in Pentium Processor notebook computers. The company expects its heat pipes to accommodate desktop computers as well. Cellular phones, camcorders, and other hand-held electronics are forsible applications for heat pipes.

  1. Astronaut Alan Bean reads data from book while holding teleprinter tape

    NASA Image and Video Library

    1973-08-08

    SL3-111-1514 (July-September 1973) --- Astronaut Alan L. Bean, Skylab 3 commander, reads data from book in his right hand while holding teleprinter tape in his left hand, in the ward room of the Skylab space station's Orbital Workshop (OWS) crew quarters. This photograph was taken with a 35mm Nikon camera held by one of Bean's fellow crewmen during the 56.5 day second manned Skylab mission in Earth orbit. Photo credit: NASA

  2. Portable Computer Keyboard For Use With One Hand

    NASA Technical Reports Server (NTRS)

    Friedman, Gary L.

    1992-01-01

    Data-entry device held in one hand and operated with five fingers. Contains seven keys. Letters, numbers, punctuation, and cursor commands keyed into computer by pressing keys in various combinations. Device called "data egg" used where standard typewriter keyboard unusable or unavailable. Contains micro-processor and 32-Kbyte memory. Captures text and transmits it to computer. Concept extended to computer mouse. Especially useful to handicapped or bedridden people who find it difficult or impossible to operate standard keyboards.

  3. Two community distracted driving programs reduce hand-held phone use : traffic tech.

    DOT National Transportation Integrated Search

    2014-03-01

    NHTSAs high-visibility enforcement (HVE) model : is a proven technique to change driver behavior and : change it quickly, thereby enhancing the effect of traffic : laws. HVE combines strong laws, vigorous highly visible : law enforcement activity,...

  4. Four High-Visibility Enforcement Demonstration Waves in Connecticut and New York Reduce Hand-Held Phone Use

    DOT National Transportation Integrated Search

    2011-07-01

    The National Highway Traffic : Safety Administration initiated : distracted driving demonstration : programs in two communities : to test whether a high-visibility : enforcement (HVE) model could : reduce two specific instances : of distracted drivin...

  5. Testing and assessment of portable seismic property analyzer.

    DOT National Transportation Integrated Search

    2014-02-01

    Investigator will thoroughly test and assess the Portable Seismic Property Analyzer (PSPA), a hand-held device that focuses on : pavement layer properties. The device can be utilized on both rigid and flexible pavements. When used on rigid pavements,...

  6. Issues in symbol design for electronic displays of navigation information

    DOT National Transportation Integrated Search

    2004-10-24

    An increasing number of electronic displays, ranging from small hand-held displays for general aviation to installed displays for air transport, are showing navigation information, such as symbols representing navigational aids. The wide range of dis...

  7. 75 FR 32803 - Notice of Issuance of Final Determination Concerning a GTX Mobile+ Hand Held Computer

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-09

    ... Programmable Read-Only Memory (``PROM'') chip, substantially transformed the PROM into a U.S. article. The... parts (such as various connectors and an Electronically Erasable Programmable Read Only Memory, or...

  8. Hand-held photomicroscopy system

    NASA Technical Reports Server (NTRS)

    Zabower, H. R.

    1972-01-01

    Photomicroscopy system, with simple optics and any standard microscope objective, is used with any type of motion picture, still, or television camera system. Device performs well under difficult environmental conditions and applies to work in ecological studies, field hospitals, and geological surveys.

  9. Cloud formation over South America - fifth orbit pass

    NASA Image and Video Library

    1962-10-03

    S62-06612 (3 Oct. 1962) --- Cloud formation over South America taken during the fifth orbit pass of the Mercury-Atlas 8 (MA-8) mission by astronaut Walter M. Schirra Jr. with a hand-held camera. Photo credit: NASA

  10. Evaluation of Patients' Satisfaction and Functional Outcome of Dorsal Hand Unit Reconstruction in Burn Patients in Shiraz, Southern Iran.

    PubMed

    Mohammadi, Ali Akbar; Foroutan, Ali; Mohammadi, Soheil; Zardosht, Mitra

    2018-06-13

    The aim of this study was to assess patients' satisfaction and functional outcome of dorsal hand unit reconstruction in burn patients in Shiraz, southern Iran.From September 2013 to February 2017, 11 patients (15 hands) with hand aesthetic complaint who were unhappy with their hand appearance were included for dorsal hand unit reconstruction. Under general anesthesia and tourniquet control, the burned tissue on dorsal surface of the hands was excised and a thick partial thickness skin graft was used for coverage, whereas the fingers were fixed by sutures to the palm. After 1 year, the five-points scale was used for evaluation of patients' satisfaction regarding the five major activities considered for hand function before and after operation. The mean age of the patients was 25.8 ± 5.17 years. The skin grafts were well taken. Six (40%) and eight patients (53%) reported the result of operation as completely satisfied and satisfied, respectively. Dorsal hand unit reconstruction in patients with dorsal hand contracture and significant dorsal scar was shown to simultaneously improve the function and aesthetic outcome of the surgery.

  11. The American Institute of Aeronautics and Astronautics pre-college outreach program

    NASA Astrophysics Data System (ADS)

    Bering, E. A.; Bacon, L.; Copper, K. K.; Hansen, L. J.; Sanchez, M. J.

    2008-12-01

    Many United States, school children perceive science, technology, engineering, and mathematics (STEM) as difficult, boring and often irrelevant subjects. The possible reasons for this problem are endlessly debated. However, the economic, social, and overall national importance of producing graduates who are technically literate and enthusiastic in their support of a rational scientific world is essential to our nation. This apparent STEM crisis should motivate the many scientific and engineering societies to develop STEM outreach programs aimed at students, parents, teachers and schools (grades K-12). The American Institute of Aeronautics and Astronautics (AIAA) is among those organizations that have identified the need to educate students and teachers about STEM current events and their direct effects on the United States population in a way that motivates both. The AIAA has established a pre-college outreach program that has several major elements that will be described in this paper. Elements focused on the teachers include a pre-college Educator Associate Membership program, classroom grants to support hands-on learning activities, Educator of the Year awards and recognition program and two national workshop events. The first workshop event, Passport to the Future, is held annually in conjunction with the Joint Propulsion Conference. It is intended to provide summertime training in Aerospace science education to classroom teachers, in conjunction with a national professional conference. The second workshop, Education Alley, is held in the fall in conjunction with the “Space” series of conferences. This program is aimed at direct outreach to local students in the conference host city, providing fun, interesting, and educational events that promote STEM. The AIAA also encourages and supports pre-college outreach activities sponsored by the local AIAA sections through leadership training, activity and material support.

  12. Subjective scaling of hand-arm vibration.

    PubMed

    Maeda, Setsuo; Shibata, Nobuyuki

    2008-04-01

    The purpose of this research was to establish a scale for comfort with regard to hand-arm vibration using the category judgment method and to validate the frequency-weighting method of the ISO 5349-1 standard. Experiments were conducted using random signals as stimuli. These stimuli consisted of three types of signal, namely designated stimulus F, with flat power spectrum density (PSD) ranging from 1 to 1,000 Hz, stimulus H with PSD which became 20 dB higher at 1,000 Hz than at 1 Hz, and stimulus L that had a PSD 20 dB lower at 1,000 Hz. These stimuli were selected from the specific spectrum patterns of hand-held vibration tools. These signals were modified by the Wh frequency weighting in accordance with ISO 5349-1, and the R.M.S. values were adjusted to be equal. In addition, the signal levels were varied over a range of five steps to create 15 kinds of individual stimuli. The subjects sat in front of a vibrator and grasped the mounted handle which exposed them to vertical vibrations after which they were asked to choose a numerical category to best indicate their perceived level of comfort (or otherwise) during each stimulus. From the experimental results of the category judgment method, the relationship between the psychological values and the frequency-weighted R.M.S. acceleration according to the ISO 5349-1 standard was obtained. It was found that the subjective response scaling of hand-arm vibration can be used for design-objective values of hand-held tool vibration.

  13. Dose-response relation between exposure to two types of hand-arm vibration and sensorineural perception of vibration.

    PubMed Central

    Virokannas, H

    1995-01-01

    OBJECTIVES--31 railway workers and 32 lumberjacks were examined to compare the dose-response relation between the exposure to two types of hand-arm vibration and the sensory disturbances in peripheral nerves as evaluated by the vibration perception thresholds (VPTs). METHODS--Clinical examinations were carried out that included measurements of the VPTs, and electroneuromyography (ENMG), and an inquiry to confirm the use of vibrating tools. Diseases of the central nervous system and neuropathies were checked by inquiry and a clinical examination, diabetes was excluded by a blood sample analysis, and the subjects with carpal tunnel syndrome confirmed with ENMG were excluded from the study. RESULTS--Lifetime use of hand held tamping machines (railway workers) and chain saws (lumberjacks) had a significant correlation with the VPTs at frequencies from 32 to 500 Hz. The increase of the VPTs (250 Hz) in relation to use of vibrating tools was 1.8-fold higher on average in the whole group and 2.3-fold higher in the young (< 45) railway workers who had used hand held tamping machines, than in the corresponding groups of lumberjacks, who had used chain saws, whereas the frequency weighted acceleration of vibration in tamping machines was fourfold. CONCLUSION--There was a significant dose-response relation between the exposure to hand-arm vibration and the VPTs. The VPTs as a function of the frequency weighted acceleration of vibration and the exposure to vibration gave promising results for assessment of the risk of damage to sensory nerves induced by vibration. PMID:7795756

  14. Air velocity distribution in a commercial broiler house

    USDA-ARS?s Scientific Manuscript database

    Increasing air velocity during tunnel ventilation in commercial broiler production facilities improves production efficiency, and many housing design specifications require a minimum air velocity. Air velocities are typically assessed with a hand-held velocity meter at random locations, rather than ...

  15. AUTOMATION OF EXPERIMENTS WITH A HAND-HELD PROGRAMMABLE CALCULATOR

    EPA Science Inventory

    Technological developments have dramatically reduced the cost of data collection, experimental control and computation. Products are now available which allow automation of experiments both in the laboratory and in the field at substantially lower cost and with less technical exp...

  16. Hybrid respiration-signal conditioner

    NASA Technical Reports Server (NTRS)

    Rinard, G. A.; Steffen, D. A.; Sturm, R. E.

    1979-01-01

    Hybrid impedance-pneumograph and respiration-rate signal conditioner element of hand-held vital signs monitor measures changes in impedance of chest during breathing cycle and generates analog respiration signal as output along with synchronous square wave that can be monitored by breath-rate processor.

  17. Field testing of hand-held infrared thermography, phase II TPF-5(247) interim report.

    DOT National Transportation Integrated Search

    2015-12-01

    This report describes research completed to develop and implement infrared thermography, a nondestructive evaluation (NDE) : technology for the condition assessment of concrete bridge components. The overall goal of this research was to develop new :...

  18. Electromagnetic and Light Scattering by Nonspherical Particles XV: Celebrating 150 Years of Maxwell's Electromagnetics

    NASA Technical Reports Server (NTRS)

    Macke, Andreas; Mishchenko, Michael I.

    2015-01-01

    The 15th Electromagnetic and Light Scattering Conference (ELS-XV) was held in Leipzig, Germany from 21 to 26 of June 2015. This conference built on the great success of the previous meetings held in Amsterdam (1995), Helsinki(1997) [2], New York City(1998) [3], Vigo (1999),Halifax (2000), Gainesville (2002), Bremen (2003), Salobreña (2005), St. Petersburg (2006), Bodrum (2007), Hatfield (2008), Helsinki (2010), Taormina (2011), and Lille as well as the workshops held in Bremen (1996,1998) and Moscow (1997). As usual, the main objective of this conference was to bring together scientists, engineers, and PhD students studying various aspects of electromagnetic scattering and to provide a relaxed atmosphere for in-depth discussion of theory, measurements, and applications. Furthermore, ELS-XV supported the United Nations "Year of Light" and celebrated the150th anniversary of Maxwell's electromagnetics. Maxwell's paper on "A Dynamical Theory of the Electromagnetic Field" was published in1865 and has widely been acknowledged as one of the supreme achievements in the history of science. The conference was attended by136 scientists from 22 countries. The scientific program included two plenary lectures, 16 invited reviews, 88 contributed oral talks, and 70 poster presentations. The program and the abstracts of conference presentations are available at the conference website http://www.els-xv-2015.net/home.html. Following the well-established ELS practice and with Elsevier's encouragement, we solicited full-size papers for a topical issue of the Journal of Quantitative Spectroscopy and Radiative Transfer (JQSRT). The result of this collective effort is now in the reader's hands. As always, every invited review and regular paper included in this topical issue has undergone the same rigorous peer review process as any other manuscript published in the JQSRT.

  19. Proceedings of the Annual Conference of the Military Testing Association (22nd) Held in Toronto, Ontario, Canada, 27-31 October 1980. Volume 1

    DTIC Science & Technology

    1980-12-01

    experimental approach . Brit. J. Educ. Psychol. 37, 1967, 81-98 -I EYSENCK, H.J.: Personality and attainment: an application of psychological principles to...and away from written testing. Accordingly, a large portion of US Army testing employs the hands-on approach to testing. 3The Hands-On Test (HOT) is...increase the amount of job- related information utilized by ratets in appraisals. All three approaches are aimed at increasing accuracy by reducing

  20. Navigating a Maze with Balance Board and Wiimote

    NASA Astrophysics Data System (ADS)

    Fikkert, Wim; Hoeijmakers, Niek; van der Vet, Paul; Nijholt, Anton

    Input from the lower body in human-computer interfaces can be beneficial, enjoyable and even entertaining when users are expected to perform tasks simultaneously. Users can navigate a virtual (game) world or even an (empirical) dataset while having their hands free to issue commands. We compared the Wii Balance Board to a hand-held Wiimote for navigating a maze and found that users completed this task slower with the Balance Board. However, the Balance Board was considered more intuitive, easy to learn and ‘much fun’.

  1. Multi-finger prehension: control of a redundant mechanical system.

    PubMed

    Latash, Mark L; Zatsiorsky, Vladimir M

    2009-01-01

    The human hand has been a fascinating object of study for researchers in both biomechanics and motor control. Studies of human prehension have contributed significantly to the progress in addressing the famous problem of motor redundancy. After a brief review of the hand mechanics, we present results of recent studies that support a general view that the apparently redundant design of the hand is not a source of computational problems but a rich apparatus that allows performing a variety of tasks in a reliable and flexible way (the principle of abundance). Multi-digit synergies have been analyzed at two levels of a hypothetical hierarchy involved in the control of prehensile actions. At the upper level, forces and moments produced by the thumb and virtual finger (an imagined finger with a mechanical action equal to the combined mechanical action of all four fingers of the hand) co-vary to stabilize the gripping action and the orientation of the hand-held object. These results support the principle of superposition suggested earlier in robotics with respect to the control of artificial grippers. At the lower level of the hierarchy, forces and moments produced by individual fingers co-vary to stabilize the magnitude and direction of the force vector and the moment of force produced by the virtual finger. Adjustments to changes in task constraints (such as, for example, friction under individual digits) may be local and synergic. The latter reflect multi-digit prehension synergies and may be analyzed with the so-called chain effects: Sequences of relatively straightforward cause-effect links directly related to mechanical constraints leading to non-trivial strong co-variation between pairs of elemental variables. Analysis of grip force adjustments during motion of hand-held objects suggests that the central nervous system adjusts to gravitational and inertial loads differently. The human hand is a gold mine for researchers interested in the control of natural human movements.

  2. EVA - ASTRONAUT EDWARD H. WHITE II - MISC. - OUTER SPACE

    NASA Image and Video Library

    1965-06-03

    S65-30271 (3 June 1965) --- Astronaut Edward H. White II, pilot on the Gemini-Titan IV (GT-4) spaceflight, floats in the zero gravity of space outside the Gemini IV spacecraft. His face is covered by a shaded visor to protect him from the unfiltered rays of the sun. White became the first American astronaut to walk in space. He remained outside the spacecraft for 21 minutes during the third revolution of the Gemini IV mission. He wears a specially designed spacesuit for the EVA. His right hand (out of frame) is holding the Hand-Held Self-Maneuvering Unit (HHSMU), with which he controlled his movements while in space, and a camera is attached to the HHSMU. He was attached to the spacecraft by a 25-feet umbilical line and a 23-feet tether line, both wrapped together with gold tape to form one cord. He wears an emergency oxygen supply check pack. Astronaut James A. McDivitt is command pilot for the GT-4 mission. The mission was a four-day, 62-revolution flight, during which McDivitt and White performed a series of scientific and engineering experiments. (This image is black and white) Photo credit: NASA EDITOR?S NOTE: Astronaut Edward H. White II died in the Apollo/Saturn 204 fire at Cape Kennedy, Florida, on Jan. 27, 1967.

  3. EVA - ASTRONAUT EDWARD H. WHITE II - MISC. - OUTER SPACE

    NASA Image and Video Library

    1965-06-03

    S65-30272 (3 June 1965) --- Astronaut Edward H. White II, pilot on the Gemini-Titan IV (GT-4) spaceflight, floats in the zero gravity of space outside the Gemini IV spacecraft. His face is covered by a shaded visor to protect him from the unfiltered rays of the sun. White became the first American astronaut to walk in space. He remained outside the spacecraft for 21 minutes during the third revolution of the Gemini IV mission. He wears a specially designed spacesuit for the EVA. His right hand is holding the Hand-Held Self-Maneuvering Unit (HHSMU), with which he controlled his movements while in space, and a camera is attached to the HHSMU. He was attached to the spacecraft by a 25-feet umbilical line and a 23-feet tether line, both wrapped together with gold tape to form one cord. He wears an emergency oxygen supply check pack. Astronaut James A. McDivitt is command pilot for the GT-4 mission. The mission was a four-day, 62-revolution flight, during which McDivitt and White performed a series of scientific and engineering experiments. (This image is black and white) Photo credit: NASA EDITOR?S NOTE: Astronaut Edward H. White II died in the Apollo/Saturn 204 fire at Cape Kennedy, Florida, on Jan. 27, 1967.

  4. EVA - ASTRONAUT EDWARD H. WHITE II - MISC. - OUTER SPACE

    NASA Image and Video Library

    1965-06-03

    S65-30273 (3 June 1965) --- Astronaut Edward H. White II, pilot on the Gemini-Titan IV (GT-4) spaceflight, floats in the zero gravity of space outside the Gemini IV spacecraft. His face is covered by a shaded visor to protect him from the unfiltered rays of the sun. White became the first American astronaut to walk in space. He remained outside the spacecraft for 21 minutes during the third revolution of the Gemini IV mission. He wears a specially designed spacesuit for the EVA. His right hand is holding the Hand-Held Self-Maneuvering Unit (HHSMU), with which he controlled his movements while in space, and a camera is attached to the HHSMU. He was attached to the spacecraft by a 25-feet umbilical line and a 23-feet tether line, both wrapped together with gold tape to form one cord. He wears an emergency oxygen supply check pack. Astronaut James A. McDivitt is command pilot for the GT-4 mission. The mission was a four-day, 62-revolution flight, during which McDivitt and White performed a series of scientific and engineering experiments. (This image is black and white) Photo credit: NASA EDITOR?S NOTE: Astronaut Edward H. White II died in the Apollo/Saturn 204 fire at Cape Kennedy, Florida, on Jan. 27, 1967.

  5. Preparing tomorrow's transportation workforce : a Midwest summit.

    DOT National Transportation Integrated Search

    2010-08-01

    Preparing Tomorrows Transportation Workforce: A Midwest Summit, held April 2728, 2010, in Ames, Iowa, was one of several : regional transportation workforce development summits held across the United States in 2009 and 2010 as part of a coordin...

  6. 1975 Ride Quality Symposium

    DOT National Transportation Integrated Search

    1975-11-01

    A compilation is presented of papers reported at the 1975 Ride Quality Symposium held in Williamsburg, Virginia, August 11-12, 1975. The symposium, jointly sponsored by NASA and the United States Department of Transportation, was held to provide a fo...

  7. Inexpensive infrared source improvised from flashlight

    NASA Technical Reports Server (NTRS)

    1966-01-01

    Inexpensive hand-held source of infrared energy is provided by a flashlight bulb coated with a paint which filters out the visible light emitted by the bulb and transmits only infrared radiation. This device can be used for checking infrared sensors and for experimental purposes.

  8. Crisis Management- Operational Logistics & Asset Visibility Technologies

    DTIC Science & Technology

    2006-06-01

    is seen as the successor to today’s bar code technology. However, passive RFID technology has several advantages over bar code technology. First...http://java.sun.com/developer/technicalArticles/ Ecommerce /rfid/ Microsoft. (2006). Hand-held RFID Reader. Retrieved May 11, 2006, from http

  9. Conceptests for a Chemical Engineering Thermodynamics Course

    ERIC Educational Resources Information Center

    Falconer, John L.

    2007-01-01

    Examples of conceptests and suggestions for preparing them for use in an undergraduate, chemical engineering thermodynamics course are presented. Conceptests, combined with hand-held transmitters (clickers), is an effective method to engage students in class. This method motivates students, improves their functional understanding of…

  10. Real-Time Hand-Held Magnetometer Array

    DTIC Science & Technology

    2016-04-01

    54 7.2.4 Detection : Probe Laser...oscillations in the F=4 hyperfine ground state and the probe beam is used to detect the oscillations. ............ 50 Figure 52. Sensor Larmor signal...level detectable by the magnetometer with a signal to noise ratio of 1:1

  11. Technical Evaluation of Metal Detectors for Concealed Weapons (Supplement 1)

    DOT National Transportation Integrated Search

    1972-04-01

    This document augments the classification and technical evaluation of Commercial Metal Detectors presented in Report No. DOT-TSC-OST-71-15, June 1971. Data based on extensive laboratory tests are presented on two hand-held models and two walk-through...

  12. 78 FR 48851 - Wireline Competition Bureau Announces Closing of the Bureau's Cost Model Virtual Workshop

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-12

    ... questions through Public Notice. DATES: Virtual workshop closure effective August 12, 2013. ADDRESSES: You.... The filing hours are 8:00 a.m. to 7:00 p.m. All hand deliveries must be held together with rubber...

  13. MS Mastracchio uses the hand-held laser rangefinder during STS-106

    NASA Image and Video Library

    2000-09-18

    STS106-320-014 (10 September 2000) --- Astronaut Richard A. Mastracchio, mission specialist, uses a handheld laser device on the aft flight deck of the Space Shuttle Atlantis to track the range of the International Space Station during rendezvous operations.

  14. 46 CFR 160.036-3 - Materials, workmanship, construction and performance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket... performance requirements. (a) Materials. The materials used in handheld rocket-propelled parachute red flare... protected against corrosion. (b) Workmanship. Handheld rocket-propelled parachute red flare distress signals...

  15. 46 CFR 160.036-3 - Materials, workmanship, construction and performance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket... performance requirements. (a) Materials. The materials used in handheld rocket-propelled parachute red flare... protected against corrosion. (b) Workmanship. Handheld rocket-propelled parachute red flare distress signals...

  16. 46 CFR 160.036-3 - Materials, workmanship, construction and performance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket... performance requirements. (a) Materials. The materials used in handheld rocket-propelled parachute red flare... protected against corrosion. (b) Workmanship. Handheld rocket-propelled parachute red flare distress signals...

  17. 46 CFR 160.036-3 - Materials, workmanship, construction and performance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket... performance requirements. (a) Materials. The materials used in handheld rocket-propelled parachute red flare... protected against corrosion. (b) Workmanship. Handheld rocket-propelled parachute red flare distress signals...

  18. 46 CFR 160.036-3 - Materials, workmanship, construction and performance requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket... performance requirements. (a) Materials. The materials used in handheld rocket-propelled parachute red flare... protected against corrosion. (b) Workmanship. Handheld rocket-propelled parachute red flare distress signals...

  19. Horizon photo of Western horizon over South America - sixth orbit pass

    NASA Image and Video Library

    1962-10-03

    S62-06604 (3 Oct. 1962) --- Western horizon over South America taken during the sixth orbit pass of the Mercury-Atlas 8 (MA-8) mission by astronaut Walter M. Schirra Jr. with a hand-held camera. Photo credit: NASA

  20. Horizon photo of Western horizon over South America - sixth orbit pass

    NASA Image and Video Library

    1962-10-03

    S62-06607 (3 Oct. 1962) --- Western horizon over South America taken during the sixth orbit pass of the Mercury-Atlas 8 (MA-8) mission by astronaut Walter M. Schirra Jr. with a hand-held camera. Photo credit: NASA

  1. Haptic guidance of overt visual attention.

    PubMed

    List, Alexandra; Iordanescu, Lucica; Grabowecky, Marcia; Suzuki, Satoru

    2014-11-01

    Research has shown that information accessed from one sensory modality can influence perceptual and attentional processes in another modality. Here, we demonstrated a novel crossmodal influence of haptic-shape information on visual attention. Participants visually searched for a target object (e.g., an orange) presented among distractor objects, fixating the target as quickly as possible. While searching for the target, participants held (never viewed and out of sight) an item of a specific shape in their hands. In two experiments, we demonstrated that the time for the eyes to reach a target-a measure of overt visual attention-was reduced when the shape of the held item (e.g., a sphere) was consistent with the shape of the visual target (e.g., an orange), relative to when the held shape was unrelated to the target (e.g., a hockey puck) or when no shape was held. This haptic-to-visual facilitation occurred despite the fact that the held shapes were not predictive of the visual targets' shapes, suggesting that the crossmodal influence occurred automatically, reflecting shape-specific haptic guidance of overt visual attention.

  2. Explaining Direct Care Resource Use of Nursing Home Residents: Findings from Time Studies in Four States

    PubMed Central

    Arling, Greg; Kane, Robert L; Mueller, Christine; Lewis, Teresa

    2007-01-01

    Objective To explain variation in direct care resource use (RU) of nursing home residents based on the Resource Utilization Groups III (RUG-III) classification system and other resident- and unit-level explanatory variables. Data Sources/Study Setting Primary data were collected on 5,314 nursing home residents in 156 nursing units in 105 facilities from four states (CO, IN, MN, MS) from 1998 to 2004. Study Design Nurses and other direct care staff recorded resident-specific and other time caring for all residents on sampled nursing units. Care time was linked to resident data from the Minimum Data Set assessment instrument. Major variables were: RUG-III group (34-group), other health and functional conditions, licensed and other professional minutes per day, unlicensed minutes per day, and direct care RU (wage-weighted minutes). Resident- and unit-level relationships were examined through hierarchical linear modeling. Data Collection/Extraction Methods Time study data were recorded with hand-held computers, verified for accuracy by project staff at the data collection sites and then merged into resident and unit-level data sets. Principal Findings Resident care time and RU varied between and within nursing units. RUG-III group was related to RU; variables such as length of stay and unit percentage of high acuity residents also were significantly related. Case-mix indices (CMIs) constructed from study data displayed much less variation across RUG-III groups than CMIs from earlier time studies. Conclusions Results from earlier time studies may not be representative of care patterns of Medicaid and private pay residents. New RUG-III CMIs should be developed to better reflect the relative costs of caring for these residents. PMID:17362220

  3. Inequalities in Specialist Hand Surgeon Distribution across the United States.

    PubMed

    Rios-Diaz, Arturo J; Metcalfe, David; Singh, Mansher; Zogg, Cheryl K; Olufajo, Olubode A; Ramos, Margarita S; Caterson, Edward J; Talbot, Simon G

    2016-05-01

    Unequal access to hospital specialists for emergency care is an issue in the United States. The authors sought to describe the geographic distribution of specialist hand surgeons and associated factors in the United States. Geographic distributions of surgeons holding a Subspecialty Certificate in Surgery of the Hand and hand surgery fellowship positions were identified from the American Board of Medical Specialties Database and the literature (2013), respectively. State-level population and per capita income were ascertained using U.S. Census data. Variations in hand trauma admissions were determined using Healthcare Cost and Utilization Project national/state inpatient databases. Risk-adjusted generalized linear models were used to assess independent association between hand surgeon density and hand trauma admission density, fellowship position density, and per capita income. Among 2019 specialist hand surgeons identified, 72.1 percent were orthopedic surgeons, 18.3 percent were plastic surgeons, and 9.6 percent were general surgeons. There were 157 hand surgery fellowship positions nationwide. There were 149,295 annual hand trauma admissions. The national density of specialist hand surgeons and density of trauma admission were 0.6 and 47.6, respectively. The density of specialist hand surgeons varied significantly between states. State-level variations in density of surgeons were independent and significantly associated with median per capita income (p < 0.001) and with density of fellowships (p = 0.014). Specialist hand surgeons are distributed unevenly across the United States. State-level analyses suggest that states with lower per capita incomes may be particularly underserved, which may contribute to regional disparities in access to emergency hand trauma care.

  4. Relative importance of modularity and other morphological attributes on different types of lithic point weapons: assessing functional variations.

    PubMed

    González-José, Rolando; Charlin, Judith

    2012-01-01

    The specific using of different prehistoric weapons is mainly determined by its physical properties, which provide a relative advantage or disadvantage to perform a given, particular function. Since these physical properties are integrated to accomplish that function, examining design variables and their pattern of integration or modularity is of interest to estimate the past function of a point. Here we analyze a composite sample of lithic points from southern Patagonia likely formed by arrows, thrown spears and hand-held points to test if they can be viewed as a two-module system formed by the blade and the stem, and to evaluate the degree in which shape, size, asymmetry, blade: stem length ratio, and tip angle explain the observed variance and differentiation among points supposedly aimed to accomplish different functions. To do so we performed a geometric morphometric analysis on 118 lithic points, departing from 24 two-dimensional landmark and semi landmarks placed on the point's contour. Klingenberg's covariational modularity tests were used to evaluate different modularity hypotheses, and a composite PCA including shape, size, asymmetry, blade: stem length ratio, and tip angle was used to estimate the importance of each attribute to explaining variation patterns. Results show that the blade and the stem can be seen as "near decomposable units" in the points integrating the studied sample. However, this modular pattern changes after removing the effects of reduction. Indeed, a resharpened point tends to show a tip/rest of the point modular pattern. The composite PCA analyses evidenced three different patterns of morphometric attributes compatible with arrows, thrown spears, and hand-held tools. Interestingly, when analyzed independently, these groups show differences in their modular organization. Our results indicate that stone tools can be approached as flexible designs, characterized by a composite set of interacting morphometric attributes, and evolving on a modular way.

  5. Magnetic profiling of the San Andreas Fault using a dual magnetometer UAV aerial survey system.

    NASA Astrophysics Data System (ADS)

    Abbate, J. A.; Angelopoulos, V.; Masongsong, E. V.; Yang, J.; Medina, H. R.; Moon, S.; Davis, P. M.

    2017-12-01

    Aeromagnetic survey methods using planes are more time-effective than hand-held methods, but can be far more expensive per unit area unless large areas are covered. The availability of low cost UAVs and low cost, lightweight fluxgate magnetometers (FGMs) allows, with proper offset determination and stray fields correction, for low-cost magnetic surveys. Towards that end, we have developed a custom multicopter UAV for magnetic mapping using a dual 3-axis fluxgate magnetometer system: the GEOphysical Drone Enhanced Survey Instrument (GEODESI). A high precision sensor measures the UAV's position and attitude (roll, pitch, and yaw) and is recorded using a custom Arduino data processing system. The two FGMs (in-board and out-board) are placed on two ends of a vertical 1m boom attached to the base of the UAV. The in-board FGM is most sensitive to stray fields from the UAV and its signal is used, after scaling, to clean the signal of the out-board FGM from the vehicle noise. The FGMs record three orthogonal components of the magnetic field in the UAV body coordinates which are then transformed into a north-east-down coordinate system using a rotation matrix determined from the roll-pitch-yaw attitude data. This ensures knowledge of the direction of all three field components enabling us to perform inverse modeling of magnetic anomalies with greater accuracy than total or vertical field measurements used in the past. Field tests were performed at Dragon's Back Pressure Ridge in the Carrizo Plain of California, where there is a known crossing of the San Andreas Fault. Our data and models were compared to previously acquired LiDAR and hand-held magnetometer measurements. Further tests will be carried out to solidify our results and streamline our processing for educational use in the classroom and student field training.

  6. Field tests of a handheld laser communications/position-finding binocular system

    NASA Astrophysics Data System (ADS)

    Chan, Victor J.; Rivers, Michael D.; Harris, Amy L.

    1998-01-01

    Lasers provide a means for transmitting larger quantities of data at higher rates than conventional radio frequency devices and can be utilized during radio silent operations on the battle field. A forward scout needs to be able to observe the positions of various targets and relay that information back to a tactical operations command center in a covert manner. The BiCom device built by Trex Communications provides laser ranging, azimuth and elevation angle to a target, GPS position information, data storage and transmit capability, and full duplex audio transmission capability, all in a 3 kg hand held package. The communication channel utilizes an eye safe lasercom transceiver for covert voice or data transfer at 100 kbps at distances of up to 5 km. The information gathered electronically by the unit is sufficient to calculate the actual GPS positions or military grid coordinates of the observed targets. Several dozen targets can be stored in memory for later transmission via lasercom. Field tests were conducted by US Army personnel to evaluate these units and compare the results with conventional means of target position determination and data transfer. A description of the system and results of these tests are presented.

  7. The reliability and validity of measurements of human dental casts made by an intra-oral 3D scanner, with conventional hand-held digital callipers as the comparison measure.

    PubMed

    Rajshekar, Mithun; Julian, Roberta; Williams, Anne-Marie; Tennant, Marc; Forrest, Alex; Walsh, Laurence J; Wilson, Gary; Blizzard, Leigh

    2017-09-01

    Intra-oral 3D scanning of dentitions has the potential to provide a fast, accurate and non-invasive method of recording dental information. The aim of this study was to assess the reliability of measurements of human dental casts made using a portable intra-oral 3D scanner appropriate for field use. Two examiners each measured 84 tooth and 26 arch features of 50 sets of upper and lower human dental casts using digital hand-held callipers, and secondly using the measuring tool provided with the Zfx IntraScan intraoral 3D scanner applied to the virtual dental casts. The measurements were repeated at least one week later. Reliability and validity were quantified concurrently by calculation of intra-class correlation coefficients (ICC) and standard errors of measurement (SEM). The measurements of the 110 landmark features of human dental casts made using the intra-oral 3D scanner were virtually indistinguishable from measurements of the same features made using conventional hand-held callipers. The difference of means as a percentage of the average of the measurements by each method ranged between 0.030% and 1.134%. The intermethod SEMs ranged between 0.037% and 0.535%, and the inter-method ICCs ranged between 0.904 and 0.999, for both the upper and the lower arches. The inter-rater SEMs were one-half and the intra-method/rater SEMs were one-third of the inter-method values. This study demonstrates that the Zfx IntraScan intra-oral 3D scanner with its virtual on-screen measuring tool is a reliable and valid method for measuring the key features of dental casts. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Cellphone-Based Hand-Held Microplate Reader for Point-of-Care Testing of Enzyme-Linked Immunosorbent Assays.

    PubMed

    Berg, Brandon; Cortazar, Bingen; Tseng, Derek; Ozkan, Haydar; Feng, Steve; Wei, Qingshan; Chan, Raymond Yan-Lok; Burbano, Jordi; Farooqui, Qamar; Lewinski, Michael; Di Carlo, Dino; Garner, Omai B; Ozcan, Aydogan

    2015-08-25

    Standard microplate based enzyme-linked immunosorbent assays (ELISA) are widely utilized for various nanomedicine, molecular sensing, and disease screening applications, and this multiwell plate batched analysis dramatically reduces diagnosis costs per patient compared to nonbatched or nonstandard tests. However, their use in resource-limited and field-settings is inhibited by the necessity for relatively large and expensive readout instruments. To mitigate this problem, we created a hand-held and cost-effective cellphone-based colorimetric microplate reader, which uses a 3D-printed opto-mechanical attachment to hold and illuminate a 96-well plate using a light-emitting-diode (LED) array. This LED light is transmitted through each well, and is then collected via 96 individual optical fibers. Captured images of this fiber-bundle are transmitted to our servers through a custom-designed app for processing using a machine learning algorithm, yielding diagnostic results, which are delivered to the user within ∼1 min per 96-well plate, and are visualized using the same app. We successfully tested this mobile platform in a clinical microbiology laboratory using FDA-approved mumps IgG, measles IgG, and herpes simplex virus IgG (HSV-1 and HSV-2) ELISA tests using a total of 567 and 571 patient samples for training and blind testing, respectively, and achieved an accuracy of 99.6%, 98.6%, 99.4%, and 99.4% for mumps, measles, HSV-1, and HSV-2 tests, respectively. This cost-effective and hand-held platform could assist health-care professionals to perform high-throughput disease screening or tracking of vaccination campaigns at the point-of-care, even in resource-poor and field-settings. Also, its intrinsic wireless connectivity can serve epidemiological studies, generating spatiotemporal maps of disease prevalence and immunity.

  9. Who actually receives cell phone use while driving citations and how much are these laws enforced among states? A descriptive, cross-sectional study.

    PubMed

    Rudisill, Toni M; Zhu, Motao

    2016-06-14

    While numerous cell phone use while driving laws have been passed among states, little information exists regarding who gets cited for these traffic infractions and how much these laws are enforced at the state-level within the USA. Cross-sectional, descriptive study. 14 states and the District of Columbia. Those receiving cell phone use while driving citations within included states from 2007 to 2013. Demographic characteristics of cited drivers were assessed. Rates of infractions per 100 000 licensed in-state drivers per year for various cell phone use while driving violations were calculated. Drivers were cited for hand-held use violations (n=2.5 million) more than texting (n=14 682) or young driver all cell phone bans (n=342). Among states that provided data for all traffic violations, cell phone use while driving citations comprised 1% of all written citations. Regardless of ban type, males (68.2%) were cited more frequently than females. Drivers 25-64 years of age (90.8%) were more likely to be cited for hand-held phone use. The average yearly rate of infractions per 100 000 licensed in-state drivers from 2010-2013 was 5.8 for texting bans, 2607 for hand-held bans, and 9954 for any traffic violation. Among cited drivers, age and sex differences existed by the type of ban violated. State-level enforcement appeared sparse. Due to the potential serious consequences of cell phone use while driving in the USA, more enforcement and targeted public safety campaigns are likely needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Who actually receives cell phone use while driving citations and how much are these laws enforced among states? A descriptive, cross-sectional study

    PubMed Central

    Rudisill, Toni M; Zhu, Motao

    2016-01-01

    Objectives While numerous cell phone use while driving laws have been passed among states, little information exists regarding who gets cited for these traffic infractions and how much these laws are enforced at the state-level within the USA. Design Cross-sectional, descriptive study. Setting 14 states and the District of Columbia. Participants Those receiving cell phone use while driving citations within included states from 2007 to 2013. Primary outcome Demographic characteristics of cited drivers were assessed. Rates of infractions per 100 000 licensed in-state drivers per year for various cell phone use while driving violations were calculated. Results Drivers were cited for hand-held use violations (n=2.5 million) more than texting (n=14 682) or young driver all cell phone bans (n=342). Among states that provided data for all traffic violations, cell phone use while driving citations comprised 1% of all written citations. Regardless of ban type, males (68.2%) were cited more frequently than females. Drivers 25–64 years of age (90.8%) were more likely to be cited for hand-held phone use. The average yearly rate of infractions per 100 000 licensed in-state drivers from 2010–2013 was 5.8 for texting bans, 2607 for hand-held bans, and 9954 for any traffic violation. Conclusions Among cited drivers, age and sex differences existed by the type of ban violated. State-level enforcement appeared sparse. Due to the potential serious consequences of cell phone use while driving in the USA, more enforcement and targeted public safety campaigns are likely needed. PMID:27301485

  11. Extra-oral dental radiography for disaster victims using a flat panel X-ray detector and a hand-held X-ray generator.

    PubMed

    Ohtani, M; Oshima, T; Mimasaka, S

    2017-12-01

    Forensic odontologists commonly incise the skin for post-mortem dental examinations when it is difficult to open the victim's mouth. However, it is prohibited by law to incise dead bodies without permission in Japan. Therefore, we attempted using extra-oral dental radiography, using a digital X-ray equipment with rechargeable batteries, to overcome this restriction. A phantom was placed in the prone position on a table, and three plain dental radiographs were used per case: "lateral oblique radiographs" for left and right posterior teeth and a "contact radiograph" for anterior teeth were taken using a flat panel X-ray detector and a hand-held X-ray generator. The resolving power of the images was measured by a resolution test chart, and the scattered X-ray dose was measured using an ionization chamber-type survey meter. The resolving power of the flat panel X-ray detector was 3.0 lp/mm, which was less than that of intra-oral dental methods, but the three extra-oral plain dental radiographs provided the overall dental information from outside of the mouth, and this approach was less time-consuming. In addition, the higher dose of scattered X-rays was laterally distributed, but the dose per case was much less than that of intra-oral dental radiographs. Extra-oral plain dental radiography can be used for disaster victim identification by dental methods even when it is difficult to open the mouth. Portable and rechargeable devices, such as a flat panel X-ray detector and a hand-held X-ray generator, are convenient to bring and use anywhere, even at a disaster scene lacking electricity and water.

  12. A novel multiwavelength fluorescence image-guided surgery imaging system

    NASA Astrophysics Data System (ADS)

    Volpi, D.; Tullis, I. D. C.; Laios, A.; Pathiraja, P. N. J.; Haldar, K.; Ahmed, A. A.; Vojnovic, B.

    2014-02-01

    We describe the development and performance analysis of two clinical near-infrared fluorescence image-guided surgery (FIGS) devices that aim to overcome some of the limitations of current FIGS systems. The devices operate in a widefield-imaging mode and can work (1) in conjunction with a laparoscope, during minimally invasive surgery, and (2) as a hand-held, open surgery imaging system. In both cases, narrow-band excitation light, delivered at multiple wavelengths, is efficiently combined with white reflectance light. Light is delivered to ~100 cm2 surgical field at 1-2 mW/cm2 for white light and 3-7 mW/cm2 (depending on wavelength) of red - near infrared excitation, at a typical working distance of 350 mm for the hand-held device and 100 mm for the laparoscope. A single, sensitive, miniaturized color camera collects both fluorescence and white reflectance light. The use of a single imager eliminates image alignment and software overlay complexity. A novel filtering and illumination arrangement allows simultaneous detection of white reflectance and fluorescence emission from multiple dyes in real-time. We will present both fluorescence detection sensitivity modeling and practical performance data. We have demonstrated the efficiency and the advantages of the devices both pre-clinically and during live surgery on humans. Both the hand-held and the laparoscopic systems have proved to be reliable and beneficial in an ongoing clinical trial involving sentinel lymph node detection in gynecological cancers. We will show preliminary results using two clinically approved dyes, Methylene blue and indocyanine green. We anticipate that this technology can be integrated and routinely used in a larger variety of surgical procedures.

  13. Detection of Francisella tularensis within infected mouse tissues by using a hand-held PCR thermocycler.

    PubMed

    Emanuel, Peter A; Bell, Ryan; Dang, Jessica L; McClanahan, Rebecca; David, John C; Burgess, Robert J; Thompson, Joseph; Collins, Lisa; Hadfield, Ted

    2003-02-01

    The diagnosis of human cases of tularemia often relies upon the demonstration of an antibody response to Francisella tularensis or the direct culturing of the bacteria from the patient. Antibody response is not detectable until 2 weeks or more after infection, and culturing requires special media and suspicion of tularemia. In addition, handling live Francisella poses a risk to laboratory personnel due to the highly infectious nature of this pathogen. In an effort to develop a rapid diagnostic assay for tularemia, we investigated the use of TaqMan 5' hydrolysis fluorogenic PCR to detect the organism in tissues of infected mice. Mice were infected to produce respiratory tularemia. The fopA and tul4 genes of F. tularensis were amplified from infected spleen, lung, liver, and kidney tissues sampled over a 5-day period. The samples were analyzed using the laboratory-based Applied Biosystems International 7900 and the Smiths Detection-Edgewood BioSeeq, a hand-held portable fluorescence thermocycler designed for use in the field. A comparison of culturing and PCR for detection of bacteria in infected tissues shows that culturing was more sensitive than PCR. However, the results for culture take 72 h, whereas PCR results were available within 4 h. PCR was able to detect infection in all the tissues tested. Lung tissue showed the earliest response at 2 days when tested with the ABI 7900 and in 3 days when tested with the BioSeeq. The results were in agreement between the ABI 7900 and the BioSeeq when presented with the same sample. Template preparation may account for the loss of sensitivity compared to culturing techniques. The hand-held BioSeeq thermocycler shows promise as an expedient means of forward diagnosis of infection in the field.

  14. Detection of Francisella tularensis within Infected Mouse Tissues by Using a Hand-Held PCR Thermocycler

    PubMed Central

    Emanuel, Peter A.; Bell, Ryan; Dang, Jessica L.; McClanahan, Rebecca; David, John C.; Burgess, Robert J.; Thompson, Joseph; Collins, Lisa; Hadfield, Ted

    2003-01-01

    The diagnosis of human cases of tularemia often relies upon the demonstration of an antibody response to Francisella tularensis or the direct culturing of the bacteria from the patient. Antibody response is not detectable until 2 weeks or more after infection, and culturing requires special media and suspicion of tularemia. In addition, handling live Francisella poses a risk to laboratory personnel due to the highly infectious nature of this pathogen. In an effort to develop a rapid diagnostic assay for tularemia, we investigated the use of TaqMan 5′ hydrolysis fluorogenic PCR to detect the organism in tissues of infected mice. Mice were infected to produce respiratory tularemia. The fopA and tul4 genes of F. tularensis were amplified from infected spleen, lung, liver, and kidney tissues sampled over a 5-day period. The samples were analyzed using the laboratory-based Applied Biosystems International 7900 and the Smiths Detection-Edgewood BioSeeq, a hand-held portable fluorescence thermocycler designed for use in the field. A comparison of culturing and PCR for detection of bacteria in infected tissues shows that culturing was more sensitive than PCR. However, the results for culture take 72 h, whereas PCR results were available within 4 h. PCR was able to detect infection in all the tissues tested. Lung tissue showed the earliest response at 2 days when tested with the ABI 7900 and in 3 days when tested with the BioSeeq. The results were in agreement between the ABI 7900 and the BioSeeq when presented with the same sample. Template preparation may account for the loss of sensitivity compared to culturing techniques. The hand-held BioSeeq thermocycler shows promise as an expedient means of forward diagnosis of infection in the field. PMID:12574268

  15. Development of a Minimum Performance Standard for Hand-Held Fire Extinguishers as a Replacement for Halon 1211 on Civilian Transport Category Aircraft

    NASA Astrophysics Data System (ADS)

    Webster, Harry

    2002-08-01

    One or more Halon 1211 hand-held fire extinguishers are specified in Federal Aviation Regulation (FAR) Part 25.851 as a requirement on transport category aircraft with 31 or more seats. Halon 1211 has been linked to the destruction of the ozone layer and production of new Halon 1211 has been halted per the Montreal Protocol in 1993. The phase out of Halon 1211, as the hand-held firefighting agent of choice, for civilian transport category aircraft has necessitated the development of a Minimum Performance Standard (MPS) to evaluate replacement agents. The purpose of the MPS is to insure that there is no reduction in safety, both in terms of effectiveness in fighting onboard fires and toxicity to the passengers and crew. The MPS specifies two new tests that replacement agents must pass in addition to requiring national certifications such as provided by Underwriters Laboratories. The first test evaluates the "flooding" characteristics of the agent against a hidden in-flight fire. This test determines the ability of a streaming agent to function as a flooding agent. The second test evaluates the performance of the agent in fighting a terrorist fire scenario and the associated toxicity hazard. This test measures the agent's ability to extinguish a triple-seat fire in an aircraft cabin under in-flight conditions and the toxicity characteristics of both the neat agent and the products of decomposition. This MPS will insure that the replacement agents will meet or exceed the performance of Halon 1211 both in fighting fires and maintaining a safe breathing environment in aircraft cabins.

  16. Use of a hand-held bladder ultrasound scanner in the assessment of dehydration and monitoring response to treatment in a paediatric emergency department.

    PubMed

    Enright, Kevin; Beattie, Tom; Taheri, Sepideh

    2010-10-01

    Dehydration is a common concern in paediatric emergency care. Limited tools are available to assess reduced urine production, which is commonly cited as a reliable marker of dehydration. To evaluate the utility of a hand-held bladder ultrasound scanner in monitoring urine production in children attending the emergency department with suspected dehydration. A prospective pilot study was undertaken on a convenience sample of patients presenting with suspected dehydration. Serial bladder ultrasound scanning was performed to monitor urine output. Dehydration was assessed clinically using the WHO guide to dehydration assessment. Decisions about treatment and admission were made independently of the urine output measurements obtained using the bladder scanner. 45 children were studied. Using the WHO guide, 33 (73%) had mild dehydration, 8 (18%) had moderate dehydration and 4 (9%) had severe dehydration. There was a significant difference in estimated urine production between those admitted and those discharged (0.9±1.2 ml/kg/h vs 1.8±1.5 ml/kg/h, p=0.01) and between those with mild dehydration versus moderate/severe dehydration (2.3±1.5 ml/kg/h vs 0.6±0.7 ml/kg/h, p=0.0011). Urine output had been significantly reduced in those who had received an intravenous fluid bolus compared with those who had not (0.4±0.46 ml/kg/h vs 1.9±1.6 ml/kg/h, p=0.001). The hand-held bladder scanner is a convenient, non-invasive and objective adjunct in the assessment and management of children attending the emergency department with suspected dehydration.

  17. Wearable Wireless Telemetry System for Implantable BioMEMS Sensors

    NASA Technical Reports Server (NTRS)

    Simons, Rainee N.; Miranda, Felix A.; Wilson, Jeffrey D.; Simons, Renita E.

    2008-01-01

    Telemetry systems of a type that have been proposed for the monitoring of physiological functions in humans would include the following subsystems: Surgically implanted or ingested units that would comprise combinations of microelectromechanical systems (MEMS)- based sensors [bioMEMS sensors] and passive radio-frequency (RF) readout circuits that would include miniature loop antennas. Compact radio transceiver units integrated into external garments for wirelessly powering and interrogating the implanted or ingested units. The basic principles of operation of these systems are the same as those of the bioMEMS-sensor-unit/external-RFpowering- and-interrogating-unit systems described in "Printed Multi-Turn Loop Antennas for Biotelemetry" (LEW-17879-1) NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 48, and in the immediately preceding article, "Hand-Held Units for Short-Range Wireless Biotelemetry" (LEW-17483-1). The differences between what is reported here and what was reported in the cited prior articles lie in proposed design features and a proposed mode of operation. In a specific system of the type now proposed, the sensor unit would comprise mainly a capacitive MEMS pressure sensor located in the annular region of a loop antenna (more specifically, a square spiral inductor/ antenna), all fabricated as an integral unit on a high-resistivity silicon chip. The capacitor electrodes, the spiral inductor/antenna, and the conductor lines interconnecting them would all be made of gold. The dimensions of the sensor unit have been estimated to be about 110.4 mm. The external garment-mounted powering/ interrogating unit would include a multi-turn loop antenna and signal-processing circuits. During operation, this external unit would be positioned in proximity to the implanted or ingested unit to provide for near-field, inductive coupling between the loop antennas, which we have as the primary and secondary windings of an electrical transformer.

  18. 31 CFR 351.60 - How are book-entry Series EE savings bonds purchased and held?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false How are book-entry Series EE savings... OFFERING OF UNITED STATES SAVINGS BONDS, SERIES EE Book-Entry Series EE Savings Bonds § 351.60 How are book-entry Series EE savings bonds purchased and held? Book-entry bonds must be purchased and held online...

  19. 31 CFR 359.45 - How are book-entry Series I savings bonds purchased and held?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false How are book-entry Series I savings... OFFERING OF UNITED STATES SAVINGS BONDS, SERIES I Book-Entry Series I Savings Bonds § 359.45 How are book-entry Series I savings bonds purchased and held? Book-entry bonds must be purchased and held online...

  20. 31 CFR 351.60 - How are book-entry Series EE savings bonds purchased and held?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 2 2013-07-01 2013-07-01 false How are book-entry Series EE savings... OFFERING OF UNITED STATES SAVINGS BONDS, SERIES EE Book-entry Series EE Savings Bonds § 351.60 How are book-entry Series EE savings bonds purchased and held? Book-entry bonds must be purchased and held online...

Top