Sample records for hand rub dispensers

  1. Recommendations and requirements for soap and hand rub dispensers in healthcare facilities.

    PubMed

    Assadian, Ojan; Kramer, Axel; Christiansen, Bärbel; Exner, Martin; Martiny, Heike; Sorger, Arno; Suchomel, Miranda

    2012-01-01

    Hand hygiene is one of the most important measures to prevent transmission of infectious agents and plays a major role in prevention of infection in any type of healthcare setting. While requirements for the efficacy of hand disinfectants are defined in European testing norms such as the EN 1500 for hygienic hand disinfection or EN 12791 for surgical hand preparation, no specific recommendations for hand rub dispensers and liquid soap dispensers have been given yet. Therefore, the intention of the present recommendation on soap and hand rub dispensers in healthcare facilities is to close this gap and to enhance future improvement of dispenser functionality and design. Regardless of manufacture and design of a hand rub or liquid soap dispensers the following requirements shall be met in healthcare facilities:Triggering the dispenser must be possible without using hands. Sensor- or elbow-operated dispensers both fulfill this requirement. Dispensers must be only refillable in a modality where the content, be it a hand rub or liquid soap, cannot be contaminated. This is achieved best by using replaceable cartridge systems. Refilling through "top-up" must not be possible. The disperser should allow usage of different types of cartridges made by different manufacturers. Dispensers must be operated and maintained such that a microbial contamination of the pump nozzle may easily be avoided. It must be possible to identify the products used in a dispenser easily and without any manipulation. Identifying the type of product, be it a hand rub or a liquid soap, as well as reading the product's name and critical manufacturers' warnings must be possible at any time. The disperser must allow identification of the level of the used product without any further manipulation at any time. The design of the dispenser must allow easy cleaning and disinfection the outside and inside of the dispenser. The manufacturer of the dispenser must provide the user with information on applicable

  2. Revisiting the hand wipe versus gel rub debate: is a higher-ethanol content hand wipe more effective than an ethanol gel rub?

    PubMed

    D'Antonio, Natalie N; Rihs, John D; Stout, Janet E; Yu, Victor L

    2010-11-01

    The Centers for Disease Control and Prevention's guidelines for hand hygiene state that the use of alcohol-based hand wipes is not an effective substitute for the use of an alcohol-based hand rub or handwashing with an antimicrobial soap and water. The objective of this study was to determine whether a hand wipe with higher ethanol content (65.9%) is as effective as an ethanol hand rub or antimicrobial soap in removing bacteria and spores from hands. In two separate experiments, the hands of 7 subjects were inoculated with a suspension of Serratia marcescens or Geobacillus stearothermophilus. Subjects washed with each of 3 different products: 65.9% ethanol hand wipes (Sani-Hands ALC), 62% ethanol gel rub (Purell), and antimicrobial soap containing 0.75% triclosan (Kindest Kare). A total of 56 observations were analyzed for S marcescens removal and 70 observations were analyzed for G stearothermophilus removal. The rank order of product efficacy for both bacteria and spore removal was antibacterial soap > 65.9% ethanol hand wipes >62% ethanol hand rub. Mean S marcescens log reductions (±SD) for the 65.9% ethanol alcohol wipe, 62% ethanol alcohol rub, and antimicrobial foam soap were 3.44 ± 0.847, 2.32 ± 1.065, and 4.44 ± 1.018, respectively (P < .001). Mean G stearothermophilus log reductions for the 65.9% ethanol wipe, 62% ethanol rub, and antimicrobial foam soap were 0.51 ± 0.26, -0.8 ± 0.32 increase over baseline, and 1.72 ± 0.62, respectively (P < .001). The alcohol-based hand wipe containing 65.9% ethanol was significantly more effective than the 62% ethanol rub in reducing the number of viable bacteria and spores on the hands. Copyright © 2010 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  3. Hand hygiene with alcohol hand rub and gloves reduces the incidence of late onset sepsis in preterm neonates.

    PubMed

    Janota, Jan; Šebková, Sylva; Višňovská, Magda; Kudláčková, Jana; Hamplová, Drahomíra; Zach, Jiří

    2014-10-01

    To assess the impact of a hand hygiene protocol, using hand washing, alcohol hand rub and gloves when caring for preterm infants born after 31 weeks of gestation, on the incidence of neonatal late onset sepsis (LOS). All babies delivered between 32 + 0 and 36 + 6 weeks gestation and admitted to the neonatal intensive care unit during a 14-month period were included. We followed a hand hygiene protocol with hand washing and alcohol hand rub (hand rub period) for the first 7 months and a protocol of hand washing, alcohol hand rub and gloves (gloves period) for the second 7 months. The hand rub and gloves groups consisted of 111 and 89 patients, respectively. Five patients were diagnosed with a total of six episodes of LOS in the hand rub group, and the incidence of LOS during the hand rub period was 2.99/1000 hospital days and 54.1/1000 admissions. There were no patients diagnosed with LOS during the gloves period (significant decrease, p = 0.028). Using a hand hygiene protocol with hand washing, hand rub and gloves significantly reduced the incidence of LOS in preterm newborns, and the results suggest that it may produce a sustained improvement in the infection rate. ©2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  4. Waterless Hand Rub Versus Traditional Hand Scrub Methods for Preventing the Surgical Site Infection in Orthopedic Surgery.

    PubMed

    Iwakiri, Kentaro; Kobayashi, Akio; Seki, Masahiko; Ando, Yoshiyuki; Tsujio, Tadao; Hoshino, Masatoshi; Nakamura, Hiroaki

    2017-11-15

    MINI: Fourteen hundred consecutive patients were investigated for evaluating the utility of waterless hand rub before orthopaedic surgery. The risk in the surgical site infection incidence was the same, but costs of liquids used for hand hygiene were cheaper and the hand hygiene time was shorter for waterless protocol, compared with traditional hand scrub. A retrospective cohort study with prospectively collected data. The aim of this study was to compare SSI incidences, the cost of hand hygiene agents, and hand hygiene time between the traditional hand scrub and the waterless hand rub protocols before orthopedic surgery. Surgical site infections (SSI) prolong hospitalization and are a leading nosocomial cause of morbidity and a source of excess cost. Recently, a waterless hand rub protocol comprising alcohol based chlorhexidine gluconate for use before surgery was developed, but no studies have yet examined its utility in orthopedic surgery. Fourteen hundred consecutive patients who underwent orthopedic surgery (spine, joint replacement, hand, and trauma surgeries) in our hospital since April 1, 2012 were included. A total of 712 cases underwent following traditional hand scrub between April 1, 2012 and April 30, 2013 and 688 cases underwent following waterless hand rub between June 1, 2013 and April 30, 2014. We compared SSI incidences within all and each subcategory between two hand hygiene protocols. All patients were screened for SSI within 1 year after surgery. We compared the cost of hand hygiene agents and hand hygiene time between two groups. The SSI incidences were 1.3% (9 of 712) following the traditional protocol (2 deep and 7 superficial infections) and 1.1% (8 of 688) following the waterless protocol (all superficial infections). There were no significant differences between the two groups. The costs of liquids used for one hand hygiene were about $2 for traditional hand scrub and less than $1 for waterless hand rub. The mean hand hygiene time was 264

  5. Single treatment with ethanol hand rub is ineffective against human rhinovirus--hand washing with soap and water removes the virus efficiently.

    PubMed

    Savolainen-Kopra, Carita; Korpela, Terttu; Simonen-Tikka, Marja-Leena; Amiryousefi, Ali; Ziegler, Thedi; Roivainen, Merja; Hovi, Tapani

    2012-03-01

    Ethanol-containing hand rubs are used frequently as a substitute for hand washing with water and soap. However, not all viruses are inactivated by a short term rubbing with alcohol. The capacity of a single round of instructed and controlled hand cleaning with water and soap or ethanol-containing hand rub, respectively, was tested for removal of human rhinovirus administered onto the skin of healthy volunteers on the back of the hands. Hand washing with soap and water appeared to be much more efficient for removing rhinoviruses from skin than rubbing hands with an ethanol-containing disinfectant. After washing with soap and water the virus was detected in 3/9 (33.3%) test persons from the left hand and 1/9 (11.1%) cases from the right hand, whereas the virus was detected invariably by real-time RT-PCR from both hands after cleaning with alcohol hand rub (P-value <0.01). Both substances evaluated clinically were also tested in vitro for virucidal efficacy against Human rhinovirus2 (HRV2) using a standardized assay. Both tested substances were poor within the contact time used in the hand-cleaning test. In conclusion, thorough and conventional hand washing with water and soap can clean efficiently hands contaminated with the virus responsible for an extensive share of common cold episodes. Copyright © 2012 Wiley Periodicals, Inc.

  6. Do WiFi-based hand hygiene dispenser systems increase hand hygiene compliance?

    PubMed

    Scheithauer, Simone; Bickenbach, Johannes; Heisel, Hans; Fehling, Patrick; Marx, Gernot; Lemmen, Sebastian

    2018-05-17

    Innovative methods to ensure better compliance in hand hygiene are urgently needed. The aim of this study was to determine if WiFi-based hand hygiene dispenser-driven self-assessment systems (Wireless Fidelity, WiFi-dispenser) can support the work of infection control teams. Our results suggest that the continuous monitoring of dispenser usage can be a valuable addition to infection prevention and control programs, when used in a bundle in combination with conventional hand hygiene training. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  7. Nudging to improve hand hygiene.

    PubMed

    Caris, M G; Labuschagne, H A; Dekker, M; Kramer, M H H; van Agtmael, M A; Vandenbroucke-Grauls, C M J E

    2018-04-01

    Hand hygiene is paramount to prevent healthcare-associated infections, but improving compliance is challenging. When healthcare workers seldom encounter healthcare-associated infections, they will consider the odds of causing infections through poor hand hygiene negligible. Cognitive biases such as these may induce non-compliance. Nudging, 'a friendly push to encourage desired behaviour', could provide an easily implemented, inexpensive measure to address cognitive biases and thus support hand hygiene interventions. To investigate whether behavioural nudges, displayed as posters, can increase the use of alcohol-based hand rub. We developed nudges based on a systematic review of previously described cognitive biases, and tested these through a cross-sectional survey among the target audience. We then conducted a controlled before-after trial on two hospital wards, to assess the effect of these nudges on the use of alcohol-based hand rub, measured with electronic dispensers. Poisson regression analyses adjusted for workload showed that nudges displayed next to dispensers increased their overall use on one ward [poster 1: relative risk: 1.6 (95% confidence interval: 1.2-2.2); poster 2: 1.7 (1.2-2.5)] and during doctor's rounds on both wards [poster 1: ward A: 1.7 (1.1-2.6); ward B: 2.2 (1.3-3.8)]. Use of dispensers without adjacent nudges did not increase. Nudges based on cognitive biases that play a role in hand hygiene, and displayed as posters, could provide an easy, inexpensive measure to increase use of alcohol-based hand rub. When applying nudges to change behaviour, it is important to identify the right nudge for the right audience. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  8. Surgical hand antisepsis in veterinary practice: evaluation of soap scrubs and alcohol based rub techniques.

    PubMed

    Verwilghen, Denis R; Mainil, Jacques; Mastrocicco, Emilie; Hamaide, Annick; Detilleux, Johann; van Galen, Gaby; Serteyn, Didier; Grulke, Sigrid

    2011-12-01

    Recent studies have shown that hydro-alcoholic solutions are more efficient than traditional medicated soaps in the pre-surgical hand antisepsis of human surgeons but there is little veterinary literature on the subject. The aim of this study was to compare the efficiency of medicated soaps and a hydro-alcoholic solution prior to surgery using an in-use testing method in a veterinary setting. A preliminary trial was performed that compared the mean log(10) number of bacterial colony forming units (CFU) and the reduction factors (RF) between two 5-min hand-scrubbing sessions using different soaps, namely, povidone iodine (PVP) and chlorhexidine gluconate (CHX), and the 1.5-min application of a hydro-alcoholic rub. A clinical in-use trial was then used to compare the hydro-alcoholic rub and CHX in a surgical setting. Sampling was performed using finger printing on agar plates. The hydro-alcoholic rub and CHX had a similar immediate effect, although the sustained effect was significantly better for the hydro-alcoholic rub, while PVP had a significantly lower immediate and sustained effect. The hydro-alcoholic rub showed good efficiency in the clinical trial and could be considered as a useful alternative method for veterinary surgical hand antisepsis. Copyright © 2010 Elsevier Ltd. All rights reserved.

  9. Hand sanitizer dispensers and associated hospital-acquired infections: friend or fomite?

    PubMed

    Eiref, Simon D; Leitman, I Michael; Riley, William

    2012-06-01

    Waterless alcohol-based hand sanitizers are an increasingly popular method of hand hygiene and help prevent hospital-acquired infection (HAI). Whether hand sanitizer dispensers (HSDs) may themselves harbor pathogens or act as fomites has not been reported. All HSDs in the surgical intensive care unit of an urban teaching hospital were cultured at three sites: The dispenser lever, the rear underside, and the area surrounding the dispensing nozzle. All HSDs yielded one or more bacterial species, including commensal skin flora and enteric gram-negative bacilli. Colonization was greatest on the lever, where there is direct hand contact. Hand sanitizer dispensers can become contaminated with pathogens that cause HAI and thus are potential fomites.

  10. Preoperative Hand Decontamination in Ophthalmic Surgery: A Comparison of the Removal of Bacteria from Surgeons' Hands by Routine Antimicrobial Scrub versus an Alcoholic Hand Rub.

    PubMed

    Forer, Yaara; Block, Colin; Frenkel, Shahar

    2017-09-01

    The goal of this experiment was to evaluate and compare the antimicrobial efficacy of routine preoperative hand washing using commercial medicated sponge brushes versus an alcoholic hand rub, by comparing bacterial growth on ophthalmic surgeons' hands after application of each of these methods. Twenty ophthalmic surgeons were recruited at the Hadassah-Hebrew University Medical Center in Jerusalem, Israel. Samples were collected twice from the hands of each surgeon after hand decontamination using two different protocols during routine surgical practice. The routine preparation consisted of a 3-minute surgical scrub using commercial brush-sponges incorporating either 4% chlorhexidine gluconate (CHG) or 1% povidone-iodine (PVP-I) formulations with detergent, followed by drying the hands with a sterile towel, while the 70% ethanol solution was applied for 60-seconds and allowed to air dry. Half of the group was randomly assigned to provide samples first after the routine method and the alcoholic solution a week later, and the other half of the group was sampled in the reverse order. Viable counts of bacteria were evaluated using a modified glove juice method. Bacterial colonies were enumerated after incubation for 24 hours and expressed as colony forming units (CFU)/mL for each pair of hands. Geometric mean counts were 1310 and 39 CFU/mL, in the routine and alcohol rub groups, respectively, representing a mean log 10 reduction in 1.53. The difference between the paired bacterial counts for the routine versus the alcohol rub was statistically significant (p < 0.0001). There was no statistically significant difference between log 10 reductions for CHG and PVP-I (p = 0.97). This study provides evidence that an alcohol rub protocol is more effective in reducing bacterial counts on hands than routine surgical hand preparation with PVP-I and CHG in a population of practicing ophthalmic surgeons in the operative clinical setting. Thus, it provides a safe alternative as a

  11. [Development of alternative to animal experiment in evaluation of skin irritation caused by alcohol-based hand rubs].

    PubMed

    Yamamoto, Nobuyuki; Miyamoto, Koji; Katoh, Masakazu

    2010-08-01

    Alcohol-based hand rubs are widely used for infection control in clinical practice. However, it is known that frequent use of the alcohol-based hand rubs may cause skin irritation. To predict the skin irritation in human, animal experiments are quite useful. Especially, the Draize Test using rabbits is suitable for this purpose because their skin is highly sensitive. On the other hand, the development of alternative to animal experiments is important not only from the viewpoint of ethical aspects but also from the efficient research and development. Reconstructed human epidermis (RhE) was developed as a human skin equivalent model in vitro, and has been applied to the evaluation of skin irritation. But the RhE has not been utilized for the evaluation of alcohol-based hand rubs because of the high skin permeability and cytotoxicity of alcohols. The aim of this study was to develop a new method using the RhE in evaluation of skin irritation caused by alcohol-based hand rubs. The authors propose an experimental technique named "Skin model blowing method (SMBM)" consisting of the sequential procedure as follows; applying small amount of testing sample on RhE, blow-dry, post incubation, and cell viability measurement. According to the SMBM, the skin irritation caused by alcohol-based hand rubs could be evaluated under the similar condition of their actual use. It was found that a high correlation existed between the cell viability obtained from SMBM and the skin irritation index in rabbit which had been reported previously.

  12. Implementing AORN recommended practices for hand hygiene.

    PubMed

    Patrick, Marcia; Van Wicklin, Sharon A

    2012-04-01

    This article focuses on implementing the revised AORN "Recommended practices for hand hygiene in the perioperative setting." The content of the document has been expanded and reorganized from the previous iteration and now includes specific activity statements about water temperature, water and soap dispensing controls, the type of dispensers to use, paper towel dispenser requirements, placement of soap and rub dispensers, and regulatory requirements for products and recommendations for hand hygiene practices. A successful hand hygiene program allows end users to have input into the selection and evaluation of products and should include educating personnel about proper hand hygiene, product composition and safety, and how and when to use specific products. Measures for competency evaluation and compliance monitoring include observations, quizzes, skills labs, electronic monitoring systems, handheld device applications, and data collection forms. Copyright © 2012 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  13. Better compliance and better tolerance in relation to a well-conducted introduction to rub-in hand disinfection.

    PubMed

    Girard, R; Amazian, K; Fabry, J

    2001-02-01

    The aim of the study was to demonstrate that the introduction of rub-in hand disinfection (RHD) in hospital units, with the implementation of suitable equipment, drafting of specific protocols, and training users, improved compliance of hand disinfection and tolerance of user's hands. In four hospital units not previously using RHD an external investigator conducted two identical studies in order to measure the rate of compliance with, and the quality of, disinfection practices, [rate of adapted (i.e., appropriate) procedures, rate of correct (i.e., properly performed) procedures, rate of adapted and correct procedures carried out] and to assess the state of hands (clinical scores of dryness and irritation, measuring hydration with a corneometer). Between the two studies, the units were equipped with dispensers for RHD products and staff were trained. Compliance improved from 62.2 to 66.5%, quality was improved (rate of adapted procedures from 66.8% to 84.3%, P > or = 10(-6), rate of correct procedures from 11.1% to 28.9%, P > or = 10(-8), rate of adapted and correct procedures from 6.0 to 17.8%, P > or = 10(-8)). The tolerance was improved significantly (P > or = 10(-2)) for clinical dryness and irritation scores, although not significantly for measurements using a corneometer. This study shows the benefit of introducing RHD with a technical and educational accompaniment. Copyright 2001 The Hospital Infection Society.

  14. Hand sanitizer-dispensing door handles increase hand hygiene compliance: a pilot study.

    PubMed

    Babiarz, Lukasz S; Savoie, Brent; McGuire, Mark; McConnell, Lauren; Nagy, Paul

    2014-04-01

    Improving rates of hand hygiene compliance (HHC) has been shown to reduce nosocomial disease. We compared the HHC for a traditional wall-mounted unit and a novel sanitizer-dispensing door handle device in a hospital inpatient ultrasound area. HHC increased 24.5%-77.1% (P < .001) for the exam room with the sanitizer-dispensing door handle, whereas it remained unchanged for the other rooms. Technical improvements like a sanitizer-dispensing door handle can improve hospital HHC. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  15. Survey of attitudes and practices of Irish nursing students towards hand hygiene, including handrubbing with alcohol-based hand rub.

    PubMed

    Kingston, Liz M; O'Connell, Nuala H; Dunne, Colum P

    2017-05-01

    Hand hygiene is widely recognised as the most important measure a healthcare worker can take in preventing the spread of healthcare associated infections. As a member of the healthcare team, nursing students have direct patient contact during clinical practice; hence, good hand hygiene practice among nursing students is essential. Low to moderate levels of hand hygiene knowledge and poor attitudes and practices are reported among nursing students. However, less is known about their attitudes and practices of handrubbing with ABHR, even though handrubbing is the recommended optimum practice in most situations. The aim of this study was to explore attitudes and practices of hand hygiene, in particular handrubbing with alcohol-based hand rub, among nursing students in Ireland. This survey employed a descriptive, self-report design using a questionnaire to gather data. It was administered electronically to all undergraduate nursing students (n=342) in the Department of Nursing and Midwifery at the University of Limerick, Ireland in March and April 2015. Response rate was 66%. Attitudes towards hand hygiene were generally positive. Compliance with hand hygiene after contact with body fluid was high (99.5%) and before a clean or aseptic procedure (98.5%). However, suboptimal practices emerged, before touching a patient (85%), after touching a patient (87%) and after touching patients' surroundings (61%), with first year students more compliant than fourth year students. 16% of students were not aware of the clinical contraindications for using alcohol-based hand rub and 9% did not know when to use soap and water and when to use alcohol-based hand rub. Educators and practitioners play an important role in ensuring that nursing students develop appropriate attitudes towards hand hygiene and engage in optimal handrubbing practices. Raising awareness among nursing students of their responsibility in preventing the occurrence and reducing the transmission of HCAI as an on

  16. Sustained antibacterial effect of a hand rub gel incorporating chlorhexdine-loaded nanocapsules (Nanochlorex).

    PubMed

    Nhung, Dang Thi Tuyet; Freydiere, Anne-Marie; Constant, Hélène; Falson, Françoise; Pirot, Fabrice

    2007-04-04

    In the present study, an original chlorhexidine-loaded nanocapsule-based gel (Nanochlorex) was tested as hand rub gel against the resident skin flora in comparison with 2-propanol 60% (v/v) and 62% (v/v) ethanol-based gel (Purell). After 30-s hand rub, the immediate bactericidal effect of Nanochlorex was found comparable to 2-propanol 60% (v/v) (reduction factor, RF: 0.30+/-0.35 versus 0.38+/-0.55, P>0.05) against aerobic bacteria, whereas the post-values of surviving anaerobes were shown significantly lower from Nanochlorex (P<0.001) and insignificant from 2-propanol 60% (v/v) (P>0.05). Sustained antibacterial effect of Nanochlorex was confirmed against the resident and transient hand flora in two sets of experiment. In the first, the results obtained with the glove-juice technique showed that the bactericidal effect induced by Nanochlorex hand rub persisted throughout 3-h period, while Purell failed to reduce significantly the post-values of surviving bacteria. In the second, repeated artificial contaminations with Staphylococcus epidermidis was carried out onto ex vivo human skin pre-treated by either Nanochlorex or Purell for 5min, then maintained in cell diffusion apparatus for 4h. The log(10) reduction of surviving bacteria was significantly higher with Nanochlorex than that determined with Purell after three successive contaminations (from approximately 5.5 to 1.5 log(10) reduction for Nanochlorex between the first and the third contamination; approximately 1log(10) reduction for Purell throughout the experiment), confirming the sustained antibacterial effect of chlorhexidine-loaded nanocapsule-based gel. The immediate and sustained antibacterial effect of Nanochlorex was explained by chlorhexidine carrier system which improved the drug targeting to bacteria and reduced from osmotic gel further bacterial growth on the skin. Nanochlorex) might constitute a promising approach for hygienic hand disinfection in care practice performing multiple procedures.

  17. Bacterial hand contamination and transfer after use of contaminated bulk-soap-refillable dispensers.

    PubMed

    Zapka, Carrie A; Campbell, Esther J; Maxwell, Sheri L; Gerba, Charles P; Dolan, Michael J; Arbogast, James W; Macinga, David R

    2011-05-01

    Bulk-soap-refillable dispensers are prone to extrinsic bacterial contamination, and recent studies demonstrated that approximately one in four dispensers in public restrooms are contaminated. The purpose of this study was to quantify bacterial hand contamination and transfer after use of contaminated soap under controlled laboratory and in-use conditions in a community setting. Under laboratory conditions using liquid soap experimentally contaminated with 7.51 log(10) CFU/ml of Serratia marcescens, an average of 5.28 log(10) CFU remained on each hand after washing, and 2.23 log(10) CFU was transferred to an agar surface. In an elementary-school-based field study, Gram-negative bacteria on the hands of students and staff increased by 1.42 log(10) CFU per hand (26-fold) after washing with soap from contaminated bulk-soap-refillable dispensers. In contrast, washing with soap from dispensers with sealed refills significantly reduced bacteria on hands by 0.30 log(10) CFU per hand (2-fold). Additionally, the mean number of Gram-negative bacteria transferred to surfaces after washing with soap from dispensers with sealed-soap refills (0.06 log(10) CFU) was significantly lower than the mean number after washing with contaminated bulk-soap-refillable dispensers (0.74 log(10) CFU; P < 0.01). Finally, significantly higher levels of Gram-negative bacteria were recovered from students (2.82 log(10) CFU per hand) than were recovered from staff (2.22 log(10) CFU per hand) after washing with contaminated bulk soap (P < 0.01). These results demonstrate that washing with contaminated soap from bulk-soap-refillable dispensers can increase the number of opportunistic pathogens on the hands and may play a role in the transmission of bacteria in public settings.

  18. Conspicuous vs customary location of hand hygiene agent dispensers on alcohol-based hand hygiene product usage in an intensive care unit.

    PubMed

    Thomas, Bruce W; Berg-Copas, Gina M; Vasquez, Donald G; Jackson, Brandy L; Wetta-Hall, Ruth

    2009-05-01

    Hand washing is considered the single most important nosocomial infection-control strategy, yet compliance rarely meets levels recommended by infection control authorities. To determine whether placement of hand hygiene foam dispensers in more conspicuous positions and closer proximity to patients would increase use of infection control agents as measured by volume of product used. Further, to ascertain the influence of dispenser placement vs the number of dispensers available on usage by volume. This prospective, observational study conducted in an intensive care unit was composed of three observation periods. A control period with standard agent dispenser location (8 dispensers) was followed by two experimental periods: (1) "conspicuous and immediate proximity to patient" placement (16 dispensers) and (2) standard locations with a dramatic increase in the number of dispensers (36 dispensers). Volume of use for alcohol-based hand hygiene agent during the three observation periods revealed a statistically significant increase in daily consumption after conspicuous and proximate positioning of dispensers (P<.001). However, increasing the number of dispensers did not increase agent use (P=.196). More conspicuous placement of dispensers containing alcohol-based hand hygiene agent (ie, immediate proximity to patients) resulted in statistically and clinically significant increases in product usage. An increase in the number of dispensers did not increase usage. The impact of dispenser positioning on usage by volume for these highly effective products should be considered when planning and implementing intensive care unit infection-control policies.

  19. Epidemiologic Background of Hand Hygiene and Evaluation of the Most Important Agents for Scrubs and Rubs

    PubMed Central

    Kampf, Günter; Kramer, Axel

    2004-01-01

    The etiology of nosocomial infections, the frequency of contaminated hands with the different nosocomial pathogens, and the role of health care workers' hands during outbreaks suggest that a hand hygiene preparation should at least have activity against bacteria, yeasts, and coated viruses. The importance of efficacy in choosing the right hand hygiene product is reflected in the new Centers for Disease Control and Prevention guideline on hand hygiene (J. M. Boyce and D. Pittet, Morb. Mortal. Wkly. Rep. 51:1-45, 2002). The best antimicrobial efficacy can be achieved with ethanol (60 to 85%), isopropanol (60 to 80%), and n-propanol (60 to 80%). The activity is broad and immediate. Ethanol at high concentrations (e.g., 95%) is the most effective treatment against naked viruses, whereas n-propanol seems to be more effective against the resident bacterial flora. The combination of alcohols may have a synergistic effect. The antimicrobial efficacy of chlorhexidine (2 to 4%) and triclosan (1 to 2%) is both lower and slower. Additionally, both agents have a risk of bacterial resistance, which is higher for chlorhexidine than triclosan. Their activity is often supported by the mechanical removal of pathogens during hand washing. Taking the antimicrobial efficacy and the mechanical removal together, they are still less effective than the alcohols. Plain soap and water has the lowest efficacy of all. In the new Centers for Disease Control and Prevention guideline, promotion of alcohol-based hand rubs containing various emollients instead of irritating soaps and detergents is one strategy to reduce skin damage, dryness, and irritation. Irritant contact dermatitis is highest with preparations containing 4% chlorhexidine gluconate, less frequent with nonantimicrobial soaps and preparations containing lower concentrations of chlorhexidine gluconate, and lowest with well-formulated alcohol-based hand rubs containing emollients and other skin conditioners. Too few published data

  20. A Kinetic Study Using Evaporation of Different Types of Hand-Rub Sanitizers

    ERIC Educational Resources Information Center

    Pinhas, Allan R.

    2010-01-01

    Alcohol-based hand-rub sanitizers are the types of products that hospital professionals use very often. These sanitizers can be classified into two major groups: those that contain a large quantity of thickener, and thus are a gel, and those that contain a small quantity of thickener, and thus remain a liquid. In an effort to create a laboratory…

  1. Towards objective hand hygiene technique assessment: validation of the ultraviolet-dye-based hand-rubbing quality assessment procedure.

    PubMed

    Lehotsky, Á; Szilágyi, L; Bánsághi, S; Szerémy, P; Wéber, G; Haidegger, T

    2017-09-01

    Ultraviolet spectrum markers are widely used for hand hygiene quality assessment, although their microbiological validation has not been established. A microbiology-based assessment of the procedure was conducted. Twenty-five artificial hand models underwent initial full contamination, then disinfection with UV-dyed hand-rub solution, digital imaging under UV-light, microbiological sampling and cultivation, and digital imaging of the cultivated flora were performed. Paired images of each hand model were registered by a software tool, then the UV-marked regions were compared with the pathogen-free sites pixel by pixel. Statistical evaluation revealed that the method indicates correctly disinfected areas with 95.05% sensitivity and 98.01% specificity. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. Hand hygiene for the prevention of nosocomial infections.

    PubMed

    Kampf, Günter; Löffler, Harald; Gastmeier, Petra

    2009-10-01

    The WHO regards hand hygiene as an essential tool for the prevention of nosocomial infection, but compliance in clinical practice is often low. The relevant scientific literature and national and international evidence-based recommendations (Robert Koch Institute [Germany], WHO) were evaluated. Hygienic hand disinfection has better antimicrobial efficacy than hand-washing and is the procedure of choice to be performed before and after manual contact with patients. The hands should be washed, rather than disinfected, only when they are visibly soiled. Skin irritation is quite common among healthcare workers and is mainly caused by water, soap, and prolonged wearing of gloves. Compliance can be improved by training, by placing hand-rub dispensers at the sites where they are needed, and by physicians setting a good example for others. Improved compliance in hand hygiene, with proper use of alcohol-based hand rubs, can reduce the nosocomial infection rate by as much as 40%.

  3. A systematic approach for the location of hand sanitizer dispensers in hospitals.

    PubMed

    Cure, Laila; Van Enk, Richard; Tiong, Ewing

    2014-09-01

    Compliance with hand hygiene practices is directly affected by the accessibility and availability of cleaning agents. Nevertheless, the decision of where to locate these dispensers is often not explicitly or fully addressed in the literature. In this paper, we study the problem of selecting the locations to install alcohol-based hand sanitizer dispensers throughout a hospital unit as an indirect approach to maximize compliance with hand hygiene practices. We investigate the relevant criteria in selecting dispenser locations that promote hand hygiene compliance, propose metrics for the evaluation of various location configurations, and formulate a dispenser location optimization model that systematically incorporates such criteria. A complete methodology to collect data and obtain the model parameters is described. We illustrate the proposed approach using data from a general care unit at a collaborating hospital. A cost analysis was performed to study the trade-offs between usability and cost. The proposed methodology can help in evaluating the current location configuration, determining the need for change, and establishing the best possible configuration. It can be adapted to incorporate alternative metrics, tailored to different institutions and updated as needed with new internal policies or safety regulation.

  4. Inefficacy of alcohol-based hand rub on mites in a patient with hyperkeratotic scabies.

    PubMed

    Cinotti, E; Perrot, J L; Labeille, B; Maguet, H; Couzan, C; Flori, P; Cambazard, F

    2015-03-01

    The World Health Organization is strongly promoting alcohol-based hand rubs to interrupt transmission of pathogens within the healthcare environment, and in some hospitals they are being recommended in cases of scabies. However, there are no studies that demonstrate the efficacy of such hand rubs against scabies. To evaluate the viability of Sarcoptes scabiei after the application of various topical antiseptics used for hand hygiene, and the effect of hand washing on the number of parasites present on the skin surface of a patient with scabies. We applied three different topical antiseptics (two alcohol-based and one povidone-iodine-based) to the skin of one hand that was affected by scabies, and took a skin scraping of each area to evaluate the viability of the mites over time. A skin scraping of a control area without antiseptic application was also taken. We also tested the antiseptics directly on the mites. Statistical comparison between the percentages of vital mites in the different samples was assessed using the χ(2) test. We also captured a dermoscopic image of the other hand before and after hand washing to count the number of parasites on the skin surface. Topical antiseptics did not reduce the number of living mites compared with control skin, and hand washing did not reduce the number of parasites on the skin surface. Application of topical antiseptics does not reduce the viability of S. scabiei, and is therefore unable to prevent the transmission of scabies. The usefulness of hand washing in preventing transmission of scabies to new subjects remains to be investigated. © 2014 British Association of Dermatologists.

  5. How a smiley protects health: A pilot intervention to improve hand hygiene in hospitals by activating injunctive norms through emoticons

    PubMed Central

    Tsivrikos, Dimitrios; Dollinger, Daniel; Lermer, Eva

    2018-01-01

    Hand hygiene practice in hospitals is unfortunately still widely insufficient, even though it is known that transmitting pathogens via hands is the leading cause of healthcare-associated infections. Previous research has shown that improving knowledge, providing feedback on past behaviour and targeting social norms are promising approaches to improve hand hygiene practices. The present field experiment was designed to direct people on when to perform hand hygiene and prevent forgetfulness. This intervention is the first to examine the effect of inducing injunctive social norms via an emoticon-based feedback system on hand hygiene behaviour. Electronic monitoring and feedback devices were installed in hospital patient rooms on top of hand-rub dispensers, next to the doorway, for a period of 17 weeks. In the emoticon condition, screens at the devices activated whenever a person entered or exited the room. Before using the alcohol-based hand-rub dispenser, a frowny face was displayed, indicating that hand hygiene should be performed. If the dispenser was subsequently used, this picture changed to a smiley face to positively reinforce the correct behaviour. Hand hygiene behaviour in the emoticon rooms significantly outperformed the behaviour in three other tested conditions. The strong effect in this field experiment indicates that activating injunctive norms may be a promising approach to improve hand hygiene behaviour. Theoretical and practical implications of these findings are discussed. PMID:29782516

  6. Surgical hand disinfection with a propanol-based hand rub: equivalence of shorter application times.

    PubMed

    Kampf, G; Ostermeyer, C; Heeg, P

    2005-04-01

    The aim of this study was to determine the efficacy of a propanol-based hand rub at application times shorter than 3 min. The bacterial pre-value was obtained from the finger tips (prEN 12791). Subjects treated their hands with the reference procedure (n-propanol, 60%) for 3 min or the product (crossover design). Sterillium was applied for 3, 2, 1.5 and 1 min. Four other preparations were tested for 1 min. Post-values (immediate effect) were taken from one hand, and the other hand was gloved for 3h. After the gloves were removed, the second post-value was taken (sustained effect). Sterillium was more effective than the reference procedure at 3, 2 and 1.5 min (immediate and sustained effect). The immediate effect after 1 min was significantly lower [mean log(10) reduction factor (RF): 1.91+/-0.90 vs. 2.52+/-0.95; P=0.001], whereas the sustained effect was not (mean RF: 1.81+/-1.06 vs. 2.05+/-1.14; P=0.204). All other preparations failed the efficacy requirement at 1 min for both the immediate and sustained effect. Using 2 x 3 mL Sterillium for a total of 1.5 min for surgical hand disinfection was at least as effective as the 3-min reference disinfection.

  7. Randomized crossover study evaluating the effect of a hand sanitizer dispenser on the frequency of hand hygiene among anesthesiology staff in the operating room.

    PubMed

    Munoz-Price, L Silvia; Patel, Zalak; Banks, Shawn; Arheart, Kristopher; Eber, Scott; Lubarsky, David A; Birnbach, David J

    2014-06-01

    Forty anesthesia providers were evaluated with and without hand sanitizer dispensers present on the anesthesia machine. Having a dispenser increased the frequency of hand hygiene only from 0.5 to 0.8 events per hour (P = .01). Other concomitant interventions are needed to further increase hand hygiene frequency among anesthesia providers.

  8. Evaluating the tolerability and acceptability of an alcohol-based hand rub - real-life experience with the WHO protocol.

    PubMed

    Wolfensberger, Aline; Durisch, Nina; Mertin, Juliane; Ajdler-Schaeffler, Evelyne; Sax, Hugo

    2015-01-01

    Optimizing user satisfaction with alcohol-based hand rubs (ABHR) may be vital to enhance hand hygiene performance. This study tested the tolerability and acceptability of a new ABHR (EVO9; Ecolab) in healthcare workers under daily working conditions and evaluated the practicability of the corresponding WHO protocol. We strictly applied the WHO single product ABHR evaluation protocol. A trained observer assessed hand skin conditions of healthy volunteers using at least 30 ml ABHR per day during their clinical work at baseline, day 3-5 and one month (visit 1-3). Participants rated ABHR tolerability and acceptability at visit 2 and 3. Additionally, we registered study time for participants and study team. Among 46 volunteers, 76% were female; 37% nurses, 28% physicians. Skin was observer-rated "not" or "incidentally" dry in 64.4%, 77.8%, and 90.9% participants at visit 1, 2, and 3, respectively. EVO9 was scored ≥5 (progressive scale, 1-7) for appearance, intactness, moisture content, and sensation by 95.7%, 97.7%, 88.9%, and 97.8% participants at visit 3, respectively. All WHO benchmarks were exceeded except for "speed of drying" at visit 2, and "texture" at visit 2 and 3. Cumulative study time expenditure was 14 days for the observer and four days for participants. EVO9 was well tolerated and accepted according to the WHO single ABHR evaluation protocol with the potential for improvement for stickiness. The WHO protocol is feasible but requires considerable time and logistics. It does not preclude bias, in this case especially due to the necessary switch to personal dispensers.

  9. Prevalence of muzzle-rubbing and hand-rubbing behavior in wild chimpanzees in Mahale Mountains National Park, Tanzania.

    PubMed

    Corp, Nadia; Hayaki, Hitoshige; Matsusaka, Takahisa; Fujita, Shiho; Hosaka, Kazuhiko; Kutsukake, Nobuyuki; Nakamura, Michio; Nakamura, Miho; Nishie, Hitonaru; Shimada, Masaki; Zamma, Koichiro; Wallauer, William; Nishida, Toshisada

    2009-04-01

    In 1998, four chimpanzees in the Mahale Mountains National Park, Tanzania, were observed wiping their mouths with non-detached leaves or stalks of grass, or rubbing their mouths with a tree trunk or branch, especially while eating lemons. The number of mouth-wiping/rubbing individuals increased to 18 in 1999. By 2005, 29 chimpanzees were documented wiping/rubbing their muzzles in this way. Although it is difficult to determine whether the chimpanzees acquired this behavior as a result of trial and error or social learning, the fact that chimpanzees at other sites perform this behavior with detached leaves or leafy twigs much more often than with intact items suggests the possibility that cleaning with intact plant parts at Mahale spread via social learning.

  10. Outbreak of human metapneumovirus infection in psychiatric inpatients: implications for directly observed use of alcohol hand rub in prevention of nosocomial outbreaks.

    PubMed

    Cheng, V C C; Wu, A K L; Cheung, C H Y; Lau, S K P; Woo, P C Y; Chan, K H; Li, K S M; Ip, I K S; Dunn, E L W; Lee, R A; Yam, L Y C; Yuen, K Y

    2007-12-01

    Nosocomial outbreaks of infectious diseases in psychiatric facilities are not uncommon but the implementation of infection control measures is often difficult. Here, we report an outbreak of an acute respiratory illness in a psychiatric ward between 29 July and 20 August 2005 involving 31 patients. Human metapneumovirus was detected in seven (23%) patients by reverse transcription-polymerase chain reaction and nucleotide sequencing. A review of outbreak surveillance records showed that six nosocomial outbreaks occurred in the year 2005, of which four (67%) were confirmed or presumably related to a respiratory viral infection. Directly observed deliveries of alcohol hand rub 4-hourly during daytime to all psychiatric patients was instituted in December 2005. Only one nosocomial respiratory viral outbreak occurred in the following year. The total number of patients and staff involved in nosocomial outbreaks due to presumed or proven respiratory virus infections decreased significantly from 60 to six (P<0.001), whereas those due to all types of nosocomial outbreaks also decreased from 70 to 24 (P=0.004). Alcohol hand rub has been shown to have potent bactericidal and virucidal activity against a wide range of nosocomial pathogens. Regular use of directly observed alcohol hand rub may decrease the incidence and scale of nosocomial outbreaks due to enveloped respiratory viruses especially in mentally incapacitated patients.

  11. Quantification of the Hawthorne effect in hand hygiene compliance monitoring using an electronic monitoring system: a retrospective cohort study

    PubMed Central

    Srigley, Jocelyn A; Furness, Colin D; Baker, G Ross; Gardam, Michael

    2014-01-01

    Background The Hawthorne effect, or behaviour change due to awareness of being observed, is assumed to inflate hand hygiene compliance rates as measured by direct observation but there are limited data to support this. Objective To determine whether the presence of hand hygiene auditors was associated with an increase in hand hygiene events as measured by a real-time location system (RTLS). Methods The RTLS recorded all uses of alcohol-based hand rub and soap for 8 months in two units in an academic acute care hospital. The RTLS also tracked the movement of hospital hand hygiene auditors. Rates of hand hygiene events per dispenser per hour as measured by the RTLS were compared for dispensers within sight of auditors and those not exposed to auditors. Results The hand hygiene event rate in dispensers visible to auditors (3.75/dispenser/h) was significantly higher than in dispensers not visible to the auditors at the same time (1.48; p=0.001) and in the same dispensers during the week prior (1.07; p<0.001). The rate increased significantly when auditors were present compared with 1–5 min prior to the auditors’ arrival (1.50; p=0.009). There were no significant changes inside patient rooms. Conclusions Hand hygiene event rates were approximately threefold higher in hallways within eyesight of an auditor compared with when no auditor was visible and the increase occurred after the auditors’ arrival. This is consistent with the existence of a Hawthorne effect localised to areas where the auditor is visible and calls into question the accuracy of publicly reported hospital hand hygiene compliance rates. PMID:25002555

  12. Quantification of the Hawthorne effect in hand hygiene compliance monitoring using an electronic monitoring system: a retrospective cohort study.

    PubMed

    Srigley, Jocelyn A; Furness, Colin D; Baker, G Ross; Gardam, Michael

    2014-12-01

    The Hawthorne effect, or behaviour change due to awareness of being observed, is assumed to inflate hand hygiene compliance rates as measured by direct observation but there are limited data to support this. To determine whether the presence of hand hygiene auditors was associated with an increase in hand hygiene events as measured by a real-time location system (RTLS). The RTLS recorded all uses of alcohol-based hand rub and soap for 8 months in two units in an academic acute care hospital. The RTLS also tracked the movement of hospital hand hygiene auditors. Rates of hand hygiene events per dispenser per hour as measured by the RTLS were compared for dispensers within sight of auditors and those not exposed to auditors. The hand hygiene event rate in dispensers visible to auditors (3.75/dispenser/h) was significantly higher than in dispensers not visible to the auditors at the same time (1.48; p=0.001) and in the same dispensers during the week prior (1.07; p<0.001). The rate increased significantly when auditors were present compared with 1-5 min prior to the auditors' arrival (1.50; p=0.009). There were no significant changes inside patient rooms. Hand hygiene event rates were approximately threefold higher in hallways within eyesight of an auditor compared with when no auditor was visible and the increase occurred after the auditors' arrival. This is consistent with the existence of a Hawthorne effect localised to areas where the auditor is visible and calls into question the accuracy of publicly reported hospital hand hygiene compliance rates. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. Comparison of 3 in vivo methods for assessment of alcohol-based hand rubs.

    PubMed

    Edmonds-Wilson, Sarah; Campbell, Esther; Fox, Kyle; Macinga, David

    2015-05-01

    Alcohol-based hand rubs (ABHRs) are the primary method of hand hygiene in health-care settings. ICPs increasingly are assessing ABHR product efficacy data as improved products and test methods are developed. As a result, ICPs need better tools and recommendations for how to assess and compare ABHRs. Two ABHRs (70% ethanol) were tested according to 3 in vivo methods approved by ASTM International: E1174, E2755, and E2784. Log10 reductions were measured after a single test product use and after 10 consecutive uses at an application volume of 2 mL. The test method used had a significant influence on ABHR efficacy; however, in this study the test product (gel or foam) did not significantly influence efficacy. In addition, for all test methods, log10 reductions obtained after a single application were not predictive of results after 10 applications. Choice of test method can significantly influence efficacy results. Therefore, when assessing antimicrobial efficacy data of hand hygiene products, ICPs should pay close attention to the test method used, and ensure that product comparisons are made head to head in the same study using the same test methodology. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  14. Quest for a Realistic In Vivo Test Method for Antimicrobial Hand-Rub Agents: Introduction of a Low-Volume Hand Contamination Procedure▿

    PubMed Central

    Macinga, David R.; Beausoleil, Christopher M.; Campbell, Esther; Mulberry, Gayle; Brady, Ann; Edmonds, Sarah L.; Arbogast, James W.

    2011-01-01

    A novel method has been developed for the evaluation of alcohol-based hand rubs (ABHR) that employs a hand contamination procedure that more closely simulates the in-use conditions of ABHR. Hands of human subjects were contaminated with 0.2 ml of a concentrated suspension of Serratia marcescens (ATCC 14756) to achieve baseline contamination between 8 and 9 log10 CFU/hand while allowing product to be applied to dry hands with minimal soil load. Evaluation of 1.5 ml of an ABHR gel containing 62% ethanol produced log10 reductions of 2.66 ± 0.96, 2.40 ± 0.50, 2.41 ± 0.61, and 2.33 ± 0.49 (means ± standard deviations) after 1, 3, 7, and 10 successive contamination/product application cycles. In a study comparing this low-volume contamination (LVC) method to ASTM E1174, product dry times were more realistic and log10 reductions achieved by the ABHR were significantly greater when LVC was employed (P < 0.05). These results indicate that a novel low-volume hand contamination procedure, which more closely represents ABHR use conditions, provides more realistic estimates of in-use ABHR efficacies. Based on the LVC method, log10 reductions produced by ABHR were strongly dependent on the test product application volume (P < 0.0001) but were not influenced by the alcohol concentration when it was within the range of 62 to 85% (P = 0.378). PMID:22003004

  15. Hand disinfection in a neonatal intensive care unit: continuous electronic monitoring over a one-year period.

    PubMed

    Helder, Onno K; van Goudoever, Johannes B; Hop, Wim C J; Brug, Johannes; Kornelisse, René F

    2012-10-08

    Good hand hygiene compliance is essential to prevent nosocomial infections in healthcare settings. Direct observation of hand hygiene compliance is the gold standard but is time consuming. An electronic dispenser with built-in wireless recording equipment allows continuous monitoring of its usage. The purpose of this study was to monitor the use of alcohol-based hand rub dispensers with a built-in electronic counter in a neonatal intensive care unit (NICU) setting and to determine compliance with hand hygiene protocols by direct observation. A one-year observational study was conducted at a 27 bed level III NICU at a university hospital. All healthcare workers employed at the NICU participated in the study. The use of bedside dispensers was continuously monitored and compliance with hand hygiene was determined by random direct observations. A total of 258,436 hand disinfection events were recorded; i.e. a median (interquartile range) of 697 (559-840) per day. The median (interquartile range) number of hand disinfection events performed per healthcare worker during the day, evening, and night shifts was 13.5 (10.8 - 16.7), 19.8 (16.3 - 24.1), and 16.6 (14.2 - 19.3), respectively. In 65.8% of the 1,168 observations of patient contacts requiring hand hygiene, healthcare workers fully complied with the protocol. We conclude that the electronic devices provide useful information on frequency, time, and location of its use, and also reveal trends in hand disinfection events over time. Direct observations offer essential data on compliance with the hand hygiene protocol. In future research, data generated by the electronic devices can be supplementary used to evaluate the effectiveness of hand hygiene promotion campaigns.

  16. Comparative assessment of local tolerance of alcohols commonly used in alcohol-based hand rubs for hand hygiene.

    PubMed

    Manche, Monique; Foligné, Benoît; Sauty, Mathieu; Platel, Anne; Vercauteren, Eric; Rauwel, Gaétan; Catoire, Sophie; Ficheux, Hervé; Criquelion, Jacques; Nesslany, Fabrice

    2017-10-01

    Hand hygiene plays a key role in nosocomial infection prevention. To achieve users' adherence, products' dermal tolerance is essential. We aimed at making a comparative assessment of skin irritation and phototoxicity of the 3 alcohols commonly used in alcohol-based hand rubs (Ethanol, Propan-2-ol, Propan-1-ol) at 60, 70, 80 or 85% w/w in water or with co-formulates (hydrating, emollient and skin protective agents). In vitro validated OECD methods 439 and 432 were used. For irritation, EpiSkin™ Small Model was the chosen Reconstructed Human Epidermis (RhE). For phototoxicity, co-formulates alone or in mixture with and without alcohol were tested using BALB/c 3T3 cell cultures. Whilst Ethanol and Propan-2-ol could not be differentiated and displayed good skin tolerance profiles, Propan-1-ol based products lead to significant viability impairments of RhE at 60, 70 or 80% and at 60% in the presence of co-formulates. However, these results could not be reproduced in another RhE model. Taking also into account bibliographic data on Propan-1-ol, this suggests that our results are probably related to a lack of specificity of the used RhE. Therefore, it can be relevant in case of significant results to use two different RhE models before performing any classification and/or performing any complementary tests. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Compressor seal rub energetics study

    NASA Technical Reports Server (NTRS)

    Laverty, W. F.

    1978-01-01

    The rub mechanics of compressor abradable blade tip seals at simulated engine conditions were investigated. Twelve statistically planned, instrumented rub tests were conducted with titanium blades and Feltmetal fibermetal rubstrips. The tests were conducted with single stationary blades rubbing against seal material bonded to rotating test disks. The instantaneous rub torque, speed, incursion rate and blade temperatures were continuously measured and recorded. Basic rub parameters (incursion rate, rub depth, abradable density, blade thickness and rub velocity) were varied to determine the effects on rub energy and heat split between the blade, rubstrip surface and rub debris. The test data was reduced, energies were determined and statistical analyses were completed to determine the primary and interactive effects. Wear surface morphology, profile measurements and metallographic analysis were used to determine wear, glazing, melting and material transfer. The rub energies for these tests were most significantly affected by the incursion rate while rub velocity and blade thickness were of secondary importance. The ratios of blade wear to seal wear were representative of those experienced in engine operation of these seal system materials.

  18. Adequate Hand Washing and Glove Use Are Necessary To Reduce Cross-Contamination from Hands with High Bacterial Loads.

    PubMed

    Robinson, Andrew L; Lee, Hyun Jung; Kwon, Junehee; Todd, Ewen; Rodriguez, Fernando Perez; Ryu, Dojin

    2016-02-01

    Hand washing and glove use are the main methods for reducing bacterial cross-contamination from hands to ready-to-eat food in a food service setting. However, bacterial transfer from hands to gloves is poorly understood, as is the effect of different durations of soap rubbing on bacterial reduction. To assess bacterial transfer from hands to gloves and to compare bacterial transfer rates to food after different soap washing times and glove use, participants' hands were artificially contaminated with Enterobacter aerogenes B199A at ∼9 log CFU. Different soap rubbing times (0, 3, and 20 s), glove use, and tomato dicing activities followed. The bacterial counts in diced tomatoes and on participants' hands and gloves were then analyzed. Different soap rubbing times did not significantly change the amount of bacteria recovered from participants' hands. Dicing tomatoes with bare hands after 20 s of soap rubbing transferred significantly less bacteria (P < 0.01) to tomatoes than did dicing with bare hands after 0 s of soap rubbing. Wearing gloves while dicing greatly reduced the incidence of contaminated tomato samples compared with dicing with bare hands. Increasing soap washing time decreased the incidence of bacteria recovered from outside glove surfaces (P < 0.05). These results highlight that both glove use and adequate hand washing are necessary to reduce bacterial cross-contamination in food service environments.

  19. A quasi-experimental study to determine the effects of a multifaceted educational intervention on hand hygiene compliance in a radiography unit.

    PubMed

    O'Donoghue, Margaret; Ng, Suk-Hing; Suen, Lorna Kp; Boost, Maureen

    2016-01-01

    Whilst numerous studies have investigated nurses' compliance with hand hygiene and use of alcohol-based hand rub (ABHR), limited attention has been paid to these issues in allied health staff. Reports have linked infections to breaches in infection control in the radiography unit (RU). With advances in medical imaging, a higher proportion of patients come into contact with RU staff increasing the need for good hand hygiene compliance. This study aimed to evaluate effectiveness on compliance of an intervention to improve awareness of hand hygiene in the RU of a district hospital. A quasi-experimental study design including questionnaires assessing knowledge and attitudes of hand hygiene and direct observation of participants was used to evaluate an educational programme on hand hygiene of the RU of a large district hospital. All healthcare workers (HCW), comprising 76 radiographers, 17 nurses, and nine healthcare assistants (HCA), agreed to participate in the study. Of these, 85 completed the initial and 76 the post-test anonymous questionnaire. The hand hygiene compliance of all 102 HCW was observed over a 3-week period prior to and after the intervention. The 2-month intervention consisted of talks on hand hygiene and benefits of ABHR, provision of visual aids, wall-mounted ABHR dispensers, and personal bottles of ABHR. Before the intervention, overall hand hygiene compliance was low (28.9 %). Post-intervention, compliance with hand hygiene increased to 51.4 %. This improvement was significant for radiographers and HCA. Additionally, knowledge and attitudes improved in particular, understanding that ABHR can largely replace handwashing and there is a need to perform hand hygiene after environmental contact. The increased use of ABHR allowed HCW to feel they had enough time to perform hand hygiene. The educational intervention led to increased awareness of hand hygiene opportunities and better acceptance of ABHR use. The reduced time needed to perform hand

  20. Effectiveness of an extended period of flashing lights and strategic signage to increase the salience of alcohol-gel dispensers for improving hand hygiene compliance.

    PubMed

    Rashidi, Babak; Li, Aimee; Patel, Rakesh; Harmsen, Irene E; Sabri, Elham; Kyeremanteng, Kwadwo; D'Egidio, Gianni

    2016-07-01

    Multiple factors affect compliance with hand hygiene, including conspicuity of alcohol-gel dispensers. Previous studies have shown that flashing lights increase hand hygiene compliance; however, the durability of this effect has not been studied. We affixed flashing lights to hand sanitizer dispensers for a total of 6 weeks. Regression analysis was used to compare compliance rates between the beginning and end of the intervention. Our secondary objective was to determine whether compliance rates in cold weather could be improved by adding a sign separated in time and space from the dispensers. Flashing lights improved hand hygiene compliance from 11.8% to 20.7%, and this effect was unchanged over the 6-week study period. Fully charged lights resulted in a greater compliance increase. A preemptive sign did not have a significant effect on hand hygiene rates nor did absolute temperatures. Flashing lights are a simple, inexpensive way of improving hand hygiene. Brighter lights appear to have a greater effect; however, this must be balanced with annoyance in specific settings. Temperature did not have a significant effect; however, this may be because the relationship does not fit a linear model. Other interventions, such as signs, may need to be tailored specifically to individual hospital environments. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  1. Neonatal ethanol exposure from ethanol-based hand sanitisers in isolettes.

    PubMed

    Hsieh, Shizuka; Sapkota, Amir; Wood, Rebecca; Bearer, Cynthia; Kapoor, Shiv

    2018-01-01

    The aims of this study is to measure the ethanol vapours in the isolette after use of hands cleaned with ethanol-based hand sanitiser (EBHS). Two squirts (1.5 mL) of hand sanitiser were rubbed on hands for 10 or 20 s before inserting the hands in the isolette for 5 min. Ethanol vapours were measured in the isolette with photoionisation detector and alcohol breathalyser for 30 min. Peak ethanol concentration in the isolette was considerably higher with a 10 s hand rub (381±192 ppm) compared with a 20 s hand rub (99±50 ppm), and dissipated to ≤5 ppm within 30 min. Under routine care, EBHS use by care providers exposes neonates in isolettes to 3.7-7.3 or 1.4-2.8 mg/kg ethanol per day with 10 or 20 s hand rubs, respectively. The expected blood level from average single exposure is 0.036 mg/dL with 10 s hand rub and may increase further with multiple exposures in a short period. Preterm neonates in the isolette are at risk of inadvertent exposure to ethanol. The expected blood alcohol level from this exposure is small and below 1 mg/dL level recommended by European Medicines Agency to limit the ethanol exposure in children. The unintended ethanol exposure can be avoided by rubbing hands for at least 20 s after applying EBHS. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Assessment of transpulmonary absorption of ethanol from alcohol-based hand rub.

    PubMed

    Hautemanière, Alexis; Ahmed-Lecheheb, Djihane; Cunat, Lisiane; Hartemann, Philippe

    2013-03-01

    Alcohol-based hand rubs (ABHRs) have been associated with a reduction of nosocomial infections. Despite the worldwide introduction of these products in health care settings, the aim of this study was to assess the transpulmonary absorption of ethanol contains in ABHRs used by health care workers (HCWs) in real conditions of work shift. Twenty-six HCWs of Nancy University Hospital were included. Research consisted in monitoring participants during 4 hours of work shift to assess their exposure to ethanol. The measurement of ethanol vapors in exhaled breath was performed using a class B ethylometer (Alco-Sensor FST). Ethanol concentration in inhaled breath was measured using Gilian pump LFS-113. Concentration of ethanol, acetaldehyde, and acetate in blood and urine samples were determined using gas chromatography with flame ionization detector. Participants were 12% male and 88% female. The mean age was 40 ± 8 years. None of the employees included in the study presented any traces of ethanol or its metabolites in the blood or urine. Ethanol (0.08 ± 0.07 mg/L) was detected in the breath of 10 HCWs at 1 to 2 minutes postexposure. The mean concentration of ethanol in the inhaled air was 46.2 mg/m. Absorption of ethanol vapor from ABHRs among HCWs during their care activities was not detected. Quantification of ethanol fumes inhaled during 4 hours of work shift was below the regulatory limitations of exposure to ethanol. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  3. Hand Hygiene – Evaluation of Three Disinfectant Hand Sanitizers in a Community Setting

    PubMed Central

    Babeluk, Rita; Jutz, Sabrina; Mertlitz, Sarah; Matiasek, Johannes; Klaus, Christoph

    2014-01-01

    Hand hygiene is acknowledged as the single most important measure to prevent nosocomial infections in the healthcare setting. Similarly, in non-clinical settings, hand hygiene is recognised as a key element in helping prevent the spread of infectious diseases. The aim of this study was to evaluate the efficacy of three different disinfectant hand sanitizers in reducing the burden of bacterial hand contamination in 60 healthy volunteers in a community setting, both before and after education about the correct use of hand sanitizers. The study is the first to evaluate the efficacy and ease of use of different formulations of hand rubs used by the general population. The products tested were: Sterillium (perfumed, liquid), desderman pure gel (odorless, gel) and Lavit (perfumed, spray). Sterillium and desderman are EN1500 (hygienic hand rub) certified products (available in pharmacy) and Lavit is non EN1500 certified and available in supermarkets. The two EN1500 certified products were found to be significantly superior in terms of reducing bacterial load. desderman pure gel, Sterillium and Lavit reduced the bacterial count to 6.4%, 8.2% and 28.0% respectively. After education in the correct use of each hand rub, the bacterial load was reduced even further, demonstrating the value of education in improving hand hygiene. Information about the testers' perceptions of the three sanitizers, together with their expectations of a hand sanitizer was obtained through a questionnaire. Efficacy, followed by skin compatibility were found to be the two most important attributes of a hand disinfectant in our target group. PMID:25379773

  4. Hand hygiene--comparison of international recommendations.

    PubMed

    Wendt, C

    2001-08-01

    The value of hand hygiene for the prevention of cross-infection was first observed in the middle of the 19th century. Since then, which procedure is the most suitable for hand hygiene has been repeatedly discussed and several different guidelines and recommendations have been published. The aim of this review is to compare different recommendations for hand hygiene regarding technique and indication. Medline, the internet and a personal library were searched to obtain as many written recommendations as possible. In addition, a small questionnaire was sent by e-mail to 20 international colleagues. As a result, written recommendations from 10 countries could be compared. Recommended methods of hand hygiene include handwashing (washing hands with plain soap), hygienic handwash (washing hands with medicated soap) and hygienic hand-rub (use of antiseptic rubs). In most countries handwashing and hygienic handwash are the methods of choice and only in central European countries is hygienic hand-rub the preferred technique. Situations in which performance of hand hygiene is recommended are comparable. However, no single indication is recommended in all guidelines. Hand hygiene is most often recommended before performing invasive procedures and after microbial contamination. Guidelines should be clear and easy to follow for them to become standard of care. Thus, guidelines are needed that do not leave to the health care worker a decision as to whether hand hygiene is indicated.

  5. Personal hand gel for improved hand hygiene compliance on the regional anesthesia team.

    PubMed

    Parks, Colby L; Schroeder, Kristopher M; Galgon, Richard E

    2015-12-01

    Hand hygiene reduces healthcare-associated infections, and several recent publications have examined hand hygiene in the perioperative period. Our institution's policy is to perform hand hygiene before and after patient contact. However, observation suggests poor compliance. This is a retrospective review of a quality improvement database showing the effect of personal gel dispensers on perioperative hand hygiene compliance on a regional anesthesia team. Healthcare providers assigned to the Acute Pain Service were observed for compliance with hand hygiene policy during a quality improvement initiative. Provider type and compliance were prospectively recorded in a database. Team members were then given a personal gel dispensing device and again observed for compliance. We have retrospectively reviewed this database to determine the effects of this intervention. Of the 307 encounters observed, 146 were prior to implementing personal gel dispensers. Compliance was 34%. Pre- and post-patient contact compliances were 23 and 43%, respectively. For 161 encounters after individual gel dispensers were provided, compliance was 63%. Pre- and post-patient contact compliances were 53 and 72%, respectively. Improvement in overall compliance from 34 to 63% was significant. On the Acute Pain Service, compliance with hand hygiene policy improves when individual sanitation gel dispensing devices are worn on the person.

  6. Rubbing ointments and asthma morbidity in adolescents.

    PubMed

    Reznik, Marina; Sharif, Iman; Ozuah, Philip O

    2004-12-01

    To determine the relationship between the use of rubbing ointments and asthma morbidity in adolescents. Cross-sectional study. Inner-city high school in the Bronx, New York. 165 adolescents with asthma. Asthma morbidity, defined as emergency department (ED) use for asthma in the past year and over the lifetime. While 127 (77%) of subjects used albuterol as the first treatment for their last asthma attack, 18 (11%) used rubbing ointments. The rubs and albuterol groups were similar in asthma severity, mean age, gender, and ethnicity. However, subjects in the the rubs group were less likely than subjects in the albuterol group to have made an ED visit over the past 12 months or over their lifetime. Regression analysis revealed that, after controlling for asthma severity, use of rubs independently predicted less lifetime ED use. After controlling for asthma severity, use of rubs by adolescents with asthma was associated with lower asthma morbidity as measured by ED use.

  7. Blade Tip Rubbing Stress Prediction

    NASA Technical Reports Server (NTRS)

    Davis, Gary A.; Clough, Ray C.

    1991-01-01

    An analytical model was constructed to predict the magnitude of stresses produced by rubbing a turbine blade against its tip seal. This model used a linearized approach to the problem, after a parametric study, found that the nonlinear effects were of insignificant magnitude. The important input parameters to the model were: the arc through which rubbing occurs, the turbine rotor speed, normal force exerted on the blade, and the rubbing coefficient of friction. Since it is not possible to exactly specify some of these parameters, values were entered into the model which bracket likely values. The form of the forcing function was another variable which was impossible to specify precisely, but the assumption of a half-sine wave with a period equal to the duration of the rub was taken as a realistic assumption. The analytical model predicted resonances between harmonics of the forcing function decomposition and known harmonics of the blade. Thus, it seemed probable that blade tip rubbing could be at least a contributor to the blade-cracking phenomenon. A full-scale, full-speed test conducted on the space shuttle main engine high pressure fuel turbopump Whirligig tester was conducted at speeds between 33,000 and 28,000 RPM to confirm analytical predictions.

  8. Influence of rubbing on rotor dynamics, part 1

    NASA Technical Reports Server (NTRS)

    Muszynska, Agnes; Bently, Donald E.; Franklin, Wesley D.; Hayashida, Robert D.; Kingsley, Lori M.; Curry, Arthur E.

    1989-01-01

    The results of analytical and experimental research on rotor-to-stationary element rubbing in rotating machines are presented. A characterization of physical phenomena associated with rubbing, as well as a literature survey on the subject of rub is given. The experimental results were obtained from two rubbing rotor rigs: one, which dynamically simulates the space shuttle main engine high pressure fuel turbopump (HPFTP), and the second one, much simpler, a two-mode rotor rig, designed for more generic studies on rotor-to-stator rubbing. Two areas were studied: generic rotor-to-stator rub-related dynamic phenomena affecting rotating machine behavior and applications to the space shuttle HPFTP. An outline of application of dynamic stiffness methodology for identification of rotor/bearing system modal parameters is given. The mathematical model of rotor/bearing/seal system under rub condition is given. The computer program was developed to calculate rotor responses. Compared with experimental results the computed results prove an adequacy of the model.

  9. Assessment of hand hygiene techniques using the World Health Organization's six steps.

    PubMed

    Arias, Ariadna V; Garcell, Humberto G; Ochoa, Yagdeline R; Arias, Katiana F; Miranda, Fernando R

    2016-01-01

    The quality of hand hygiene was evaluated via direct observation for compliance with the six recommended World Health Organization steps. A total of 2497 HH opportunities, of which 1573 (63.0%) were hand rubs, were monitored over a five month period. Compliance was higher in nurses compared with physicians and auxiliaries and in steps 1 and 2 for hand rubs as well as the first three steps of hand washing, with lower rates after these steps. Rubbing of the thumbs and fingertips achieved the lowest rates of compliance in both HH types. A combination of the five recommended moments and six steps and staff education is recommended to improve the quality of hand hygiene. Copyright © 2015 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  10. Recognition and Cleavage of Related to Ubiquitin 1 (Rub1) and Rub1-Ubiquitin Chains by Components of the Ubiquitin-Proteasome System*

    PubMed Central

    Singh, Rajesh K.; Zerath, Sylvia; Kleifeld, Oded; Scheffner, Martin; Glickman, Michael H.; Fushman, David

    2012-01-01

    Of all ubiquitin-like proteins, Rub1 (Nedd8 in mammals) is the closest kin of ubiquitin. We show via NMR that structurally, Rub1 and ubiquitin are fundamentally similar as well. Despite these profound similarities, the prevalence of Rub1/Nedd8 and of ubiquitin as modifiers of the proteome is starkly different, and their attachments to specific substrates perform different functions. Recently, some proteins, including p53, p73, EGFR, caspase-7, and Parkin, have been shown to be modified by both Rub1/Nedd8 and ubiquitin within cells. To understand whether and how it might be possible to distinguish among the same target protein modified by Rub1 or ubiquitin or both, we examined whether ubiquitin receptors can differentiate between Rub1 and ubiquitin. Surprisingly, Rub1 interacts with proteasome ubiquitin-shuttle proteins comparably to ubiquitin but binds more weakly to a proteasomal ubiquitin receptor Rpn10. We identified Rub1-ubiquitin heteromers in yeast and Nedd8-Ub heteromers in human cells. We validate that in human cells and in vitro, human Rub1 (Nedd8) forms chains with ubiquitin where it acts as a chain terminator. Interestingly, enzymatically assembled K48-linked Rub1-ubiquitin heterodimers are recognized by various proteasomal ubiquitin shuttles and receptors comparably to K48-linked ubiquitin homodimers. Furthermore, these heterologous chains are cleaved by COP9 signalosome or 26S proteasome. A derubylation function of the proteasome expands the repertoire of its enzymatic activities. In contrast, Rub1 conjugates may be somewhat resilient to the actions of other canonical deubiquitinating enzymes. Taken together, these findings suggest that once Rub1/Nedd8 is channeled into ubiquitin pathways, it is recognized essentially like ubiquitin. PMID:23105008

  11. Modeling the rubbing contact in honeycomb seals

    NASA Astrophysics Data System (ADS)

    Fischer, Tim; Welzenbach, Sarah; Meier, Felix; Werner, Ewald; kyzy, Sonun Ulan; Munz, Oliver

    2018-03-01

    Metallic honeycomb labyrinth seals are commonly used as sealing systems in gas turbine engines. Because of their capability to withstand high thermo-mechanical loads and oxidation, polycrystalline nickel-based superalloys, such as Hastelloy X and Haynes 214, are used as sealing material. In addition, these materials must exhibit a tolerance against rubbing between the rotating part and the stationary seal component. The tolerance of the sealing material against rubbing preserves the integrity of the rotating part. In this article, the rubbing behavior at the rotor-stator interface is considered numerically. A simulation model is incorporated into the commercial finite element code ABAQUS/explicit and is utilized to simulate a simplified rubbing process. A user-defined interaction routine between the contact surfaces accounts for the thermal and mechanical interfacial behavior. Furthermore, an elasto-plastic constitutive material law captures the extreme temperature conditions and the damage behavior of the alloys. To validate the model, representative quantities of the rubbing process are determined and compared with experimental data from the literature. The simulation results correctly reproduce the observations made on a test rig with a reference stainless steel material (AISI 304). A parametric study using the nickel-based superalloys reveals a clear dependency of the rubbing behavior on the sliding and incursion velocity. Compared to each other, the two superalloys studied exhibit a different rubbing behavior.

  12. Less and less-influence of volume on hand coverage and bactericidal efficacy in hand disinfection.

    PubMed

    Kampf, Günter; Ruselack, Sigunde; Eggerstedt, Sven; Nowak, Nicolas; Bashir, Muhammad

    2013-10-10

    Some manufacturers recommend using 1.1 mL per application of alcohol-based handrubs for effective hand disinfection. However, whether this volume is sufficient to cover both hands, as recommended by the World Health Organization, and fulfills current efficacy standards is unknown. This study aimed to determine hand coverage for three handrubs (two gels based on 70% v/v and 85% w/w ethanol and a foam based on 70% v/v ethanol) applied at various volumes. Products were tested at product volumes of 1.1 mL, 2 mL, 2.4 mL as well as 1 and 2 pump dispenser pushes; the foam product was tested in addition at foam volumes of 1.1 mL, 2 mL, and 2.4 mL. Products were supplemented with a fluorescent dye and 15 participants applied products using responsible application techniques without any specific steps but the aim of completely covering both hands. Coverage quality was determined under ultraviolet light by two blinded investigators. Efficacy of the three handrubs was determined according to ASTM E 1174-06 and ASTM E 2755-10. For each experiment, the hands of 12 participants were contaminated with Serratia marcescens and the products applied as recommended (1.1 mL for 70% v/v ethanol products; 2 mL for the 85% w/w ethanol product). Log10-reduction was calculated. Volumes < 2 mL yielded high rates of incomplete coverage (67%-87%) whereas volumes ≥ 2 mL gave lower rates (13%-53%). Differences in coverage were significant between the five volumes tested for all handrubs (p < 0.001; two-way ANOVA) but not between the three handrubs themselves (p = 0.796). Application of 1.1 mL of 70% v/v ethanol rubs reduced contamination by 1.85 log10 or 1.60 log10 (ASTM E 1174-06); this failed the US FDA efficacy requirement of at least 2 log10. Application of 2 mL of the 85% w/w ethanol rub reduced contamination by 2.06 log10 (ASTM E 1174-06), fulfilling the US FDA efficacy requirement. Similar results were obtained according to ASTM E 2755-10. Our data indicated that

  13. Less and less–influence of volume on hand coverage and bactericidal efficacy in hand disinfection

    PubMed Central

    2013-01-01

    Background Some manufacturers recommend using 1.1 mL per application of alcohol-based handrubs for effective hand disinfection. However, whether this volume is sufficient to cover both hands, as recommended by the World Health Organization, and fulfills current efficacy standards is unknown. This study aimed to determine hand coverage for three handrubs (two gels based on 70% v/v and 85% w/w ethanol and a foam based on 70% v/v ethanol) applied at various volumes. Methods Products were tested at product volumes of 1.1 mL, 2 mL, 2.4 mL as well as 1 and 2 pump dispenser pushes; the foam product was tested in addition at foam volumes of 1.1 mL, 2 mL, and 2.4 mL. Products were supplemented with a fluorescent dye and 15 participants applied products using responsible application techniques without any specific steps but the aim of completely covering both hands. Coverage quality was determined under ultraviolet light by two blinded investigators. Efficacy of the three handrubs was determined according to ASTM E 1174-06 and ASTM E 2755-10. For each experiment, the hands of 12 participants were contaminated with Serratia marcescens and the products applied as recommended (1.1 mL for 70% v/v ethanol products; 2 mL for the 85% w/w ethanol product). Log10-reduction was calculated. Results Volumes < 2 mL yielded high rates of incomplete coverage (67%–87%) whereas volumes ≥ 2 mL gave lower rates (13%–53%). Differences in coverage were significant between the five volumes tested for all handrubs (p < 0.001; two-way ANOVA) but not between the three handrubs themselves (p = 0.796). Application of 1.1 mL of 70% v/v ethanol rubs reduced contamination by 1.85 log10 or 1.60 log10 (ASTM E 1174-06); this failed the US FDA efficacy requirement of at least 2 log10. Application of 2 mL of the 85% w/w ethanol rub reduced contamination by 2.06 log10 (ASTM E 1174-06), fulfilling the US FDA efficacy requirement. Similar results were obtained according to ASTM E 2755

  14. Quantitative impact of direct, personal feedback on hand hygiene technique.

    PubMed

    Lehotsky, Á; Szilágyi, L; Ferenci, T; Kovács, L; Pethes, R; Wéber, G; Haidegger, T

    2015-09-01

    This study investigated the effectiveness of targeting hand hygiene technique using a new training device that provides objective, personal and quantitative feedback. One hundred and thirty-six healthcare workers in three Hungarian hospitals participated in a repetitive hand hygiene technique assessment study. Ultraviolet (UV)-labelled hand rub was used at each event, and digital images of the hands were subsequently taken under UV light. Immediate objective visual feedback was given to participants, showing missed areas on their hands. The rate of inadequate hand rubbing reduced from 50% to 15% (P < 0.001). However, maintenance of this reduced rate is likely to require continuous use of the electronic equipment. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  15. Effect of hand sanitizer location on hand hygiene compliance.

    PubMed

    Cure, Laila; Van Enk, Richard

    2015-09-01

    Hand hygiene is the most important intervention to prevent infection in hospitals. Health care workers should clean their hands at least before and after contact with patients. Hand sanitizer dispensers are important to support hand hygiene because they can be made available throughout hospital units. The aim of this study was to determine whether the usability of sanitizer dispensers correlates with compliance of staff in using the sanitizer in a hospital. This study took place in a Midwest, 404-bed, private, nonprofit community hospital with 15 inpatient care units in addition to several ambulatory units. The usability and standardization of sanitizers in 12 participating inpatient units were evaluated. The hospital measured compliance of staff with hand hygiene as part of their quality improvement program. Data from 2010-2012 were analyzed to measure the relationship between compliance and usability using mixed-effects logistic regression models. The total usability score (P = .0046), visibility (P = .003), and accessibility of the sanitizer on entrance to the patient room (P = .00055) were statistically associated with higher observed compliance rates. Standardization alone showed no significant impact on observed compliance (P = .37). Hand hygiene compliance can be influenced by visibility and accessibility of dispensers. The sanitizer location should be part of multifaceted interventions to improve hand hygiene. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  16. Mechanisms of rubbing-related corneal trauma in keratoconus.

    PubMed

    McMonnies, Charles W

    2009-07-01

    Corneal scarring in keratoconus, which is observed prior to contact lens wear and in association with a chronic habit of abnormal rubbing, suggests a keratocyte change to a repair phenotype in response to rubbing trauma. This review examines known and putative mechanisms for rubbing-related corneal trauma and cone formation. Responses to eye rubbing (and possible causal links) may include increased corneal temperature, epithelial thinning, increased concentrations of inflammatory mediators in the precorneal tears, abnormal enzyme activity, large intraocular pressure spikes, high hydrostatic tissue pressure, thixotropically reduced ground substance viscosity, temporary displacement of ground substance from the corneal apex, buckling and flexure of fibrils associated with waves of corneal indentation, biomechanically coupled curvature transfer to the cone apex, slippage between collagen fibrils at the cone apex, and changes to keratocytes due to mechanical trauma and/or high hydrostatic pressure, in addition to scar formation. Cone formation appears to depend on a loss of shear strength and may be a consequence of a reduction in ground substance viscosity and glue function, which could allow the cornea to bend and yield to intraocular pressure. For some forms of keratoconus, a reduction in shear strength and cone-forming deformation may be responses to rubbing trauma. Some of the mechanisms for corneal rubbing trauma may be relevant to post-laser-assisted in situ keratomileusis ectasia or complications following other types of corneal surgery. There appear to be indications for the control of chronic habits of abnormal rubbing.

  17. Evaluation of pheromone release from commercial mating disruption dispensers.

    PubMed

    Tomaszewska, Elizabeth; Hebert, Vincent R; Brunner, Jay F; Jones, Vincent P; Doerr, Mike; Hilton, Richard

    2005-04-06

    Pome fruit growers and crop consultants have expressed concerns about the seasonal release performance of commercial codling moth mating disruption dispenser products. Because of these concerns, we developed a laboratory flow-through volatile collection system (VCS) for measuring the volatile release of the codling moth sex pheromone, codlemone, from commercially available hand-applied dispensers. Under controlled air-flow and temperature conditions, the released vapor was trapped onto a polyurethane foam adsorbent followed by solvent extraction, solvent reduction, and GC/MS determination. Method recovery and breakthrough validations were performed to demonstrate system reliability before determining codlemone release from commercial dispensers field-aged over 140 days. The volatile collection was carried out in a consistent manner among five dispenser types most commonly used by growers, so that direct comparison of performance could be made. The comparison showed differences in the amount of pheromone released and in the patterns of release throughout the season between dispenser types. The variation in release performance demonstrates the need for routine evaluation of commercially marketed mating disruption dispensers. We believe that the simple and cost-effective volatile collection system can assist pheromone dispenser manufacturers in determining seasonal dispenser performance before new products are introduced into the commercial market and in rapidly verifying dispenser release when field-aged dispenser efficacy is in question.

  18. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light...

  19. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light...

  20. Rubbings deposited by cats elicit defensive behavior in rats.

    PubMed

    May, Matthew D; Bowen, Michael T; McGregor, Iain S; Timberlake, William

    2012-12-05

    Laboratory rats display pronounced defensive behaviors when confronted with a range of cat-derived stimuli, including collars worn by a cat, cloths rubbed on a cat, and cat fur. One possible explanation of this phenomenon (the "kairomone hypothesis") is that rats derive a survival advantage by eavesdropping on signals used by cats to communicate with each other. Cats are known to rub their bodies on objects at strategic environmental locations to signal their identity and mating potential to other cats. The current study assessed the sensitivity of laboratory rats to these body rubbings. In Experiment 1, food deprived Sprague-Dawley rats were trained to consume food pellets in one arm of a Y maze. On test day a damp cloth was placed near the food pellets that had been rubbed on a location (wall) where a cat had recently engaged in body rubbing. A control cloth and a collar worn by the cat were also tested. The presence of both the body rubbing residue and the cat collar increased latency to eat and decreased amount of food eaten. The disruption of consummatory behavior in the test environment was still evident 24h later in the absence of odor stimuli. Experiment 2 tested the reaction of naïve Wistar rats to body rubbings using a paradigm in which rats were given the opportunity to hide. Relative to a control condition, rats exposed to a cotton pad wiped on a cat body rubbing location showed increased hiding behavior, decreased exploration and reduced stimulus approach and investigation. These defensive responses persisted for up to 4days following a single stimulus exposure. These results suggest that rats eavesdrop readily on body rubbings cats use for identification purposes, providing further support for a kairomone hypothesis of predator odor avoidance. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Numerical investigations on axial and radial blade rubs in turbo-machinery

    NASA Astrophysics Data System (ADS)

    Abdelrhman, Ahmed M.; Tang, Eric Sang Sung; Salman Leong, M.; Al-Qrimli, Haidar F.; Rajamohan, G.

    2017-07-01

    In the recent years, the clearance between the rotor blades and stator/casing had been getting smaller and smaller prior improving the aerodynamic efficiency of the turbomachines as demand in the engineering field. Due to the clearance reduction between the blade tip and the rotor casing and between rotor blades and stator blades, axial and radial blade rubbing could be occurred, especially at high speed resulting into complex nonlinear vibrations. The primary aim of this study is to address the blade axial rubbing phenomenon using numerical analysis of rotor system. A comparison between rubbing caused impacts of axial and radial blade rubbing and rubbing forces are also aims of this study. Tow rotor models (rotor-stator and rotor casing models) has been designed and sketched using SOILDSWORKS software. ANSYS software has been used for the simulation and the numerical analysis. The rubbing conditions were simulated at speed range of 1000rpm, 1500rpm and 2000rpm. Analysis results for axial blade rubbing showed the appearance of blade passing frequency and its multiple frequencies (lx, 2x 3x etc.) and these frequencies will more excited with increasing the rotational speed. Also, it has been observed that when the rotating speed increased, the rubbing force and the harmonics frequencies in x, y and z-direction become higher and severe. The comparison study showed that axial blade rub is more dangerous and would generate a higher vibration impacts and higher blade rubbing force than radial blade rub.

  2. Medicare and Medicaid programs; fire safety requirements for certain health care facilities; amendment. Interim final rule with comment period.

    PubMed

    2005-03-25

    This interim final rule with comment period adopts the substance of the April 15, 2004 temporary interim amendment (TIA) 00-1 (101), Alcohol Based Hand Rub Solutions, an amendment to the 2000 edition of the Life Safety Code, published by the National Fire Protection Association (NFPA). This amendment will allow certain health care facilities to place alcohol-based hand rub dispensers in egress corridors under specified conditions. This interim final rule with comment period also requires that nursing facilities install smoke detectors in resident rooms and public areas if they do not have a sprinkler system installed throughout the facility or a hard-wired smoke detection system in those areas.

  3. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220... STANDARDS) United States Standards for Grades of Peaches Definitions § 51.1220 Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light colored, or aggregates more...

  4. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220... STANDARDS) United States Standards for Grades of Peaches Definitions § 51.1220 Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light colored, or aggregates more...

  5. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220... STANDARDS) United States Standards for Grades of Peaches Definitions § 51.1220 Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light colored, or aggregates more...

  6. 42 CFR 403.744 - Condition of participation: Life safety from fire.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... written fire control plans that contain provisions for prompt reporting of fires; extinguishing fires...) The RNHCI must maintain written evidence of regular inspection and approval by State or local fire... contrary, the RNHCI may place alcohol-based hand rub dispensers in its facility if— (i) Use of alcohol...

  7. Comparison of hand hygiene procedures for removing Bacillus cereus spores.

    PubMed

    Sasahara, Teppei; Hayashi, Shunji; Hosoda, Kouichi; Morisawa, Yuji; Hirai, Yoshikazu

    2014-01-01

    Bacillus cereus is a spore-forming bacterium. B. cereus occasionally causes nosocomial infections, in which hand contamination with the spores plays an important role. Therefore, hand hygiene is the most important practice for controlling nosocomial B. cereus infections. This study aimed to determine the appropriate hand hygiene procedure for removing B. cereus spores. Thirty volunteers' hands were experimentally contaminated with B. cereus spores, after which they performed 6 different hand hygiene procedures. We compared the efficacy of the procedures in removing the spores from hands. The alcohol-based hand-rubbing procedures scarcely removed them. The soap washing procedures reduced the number of spores by more than 2 log10. Extending the washing time increased the spore-removing efficacy of the washing procedures. There was no significant difference in efficacy between the use of plain soap and antiseptic soap. Handwashing with soap is appropriate for removing B. cereus spores from hands. Alcohol-based hand-rubbing is not effective.

  8. Influence of rubbing on rotor dynamics, part 2

    NASA Technical Reports Server (NTRS)

    Muszynska, Agnes; Bently, Donald E.; Franklin, Wesley D.; Hayashida, Robert D.; Kingsley, Lori M.; Curry, Arthur E.

    1989-01-01

    Rotor dynamic behavior depends considerably on how much the specific physical phenomena accompanying rotor rubbing against the stator is involved. The experimental results of rotor-to-stator rubbing contact are analyzed. The computer code is described for obtaining numerical calculations of rotor-to-stator rubbing system dynamic responses. Computer generated results are provided. The reduced dynamic data from High Pressure Fuel Turbo Pump (HPFTP) hot fire test are given. The results provide some significant conclusions. Information is provided on the electronic instrumentation used in the experimental testing.

  9. Do hospital visitors wash their hands? Assessing the use of alcohol-based hand sanitizer in a hospital lobby.

    PubMed

    Birnbach, David J; Nevo, Igal; Barnes, Susan; Fitzpatrick, Maureen; Rosen, Lisa F; Everett-Thomas, Ruth; Sanko, Jill S; Arheart, Kristopher L

    2012-05-01

    Reports regarding hand hygiene compliance (HHC) among hospital visitors are limited. Although there is an implicit assumption that the availability of alcohol-based hand sanitizer (AHS) promotes visitor HHC, the degree of AHS use by visitors remains unclear. To assess AHS use, we observed visitor HHC and how it is affected by visual cues in a private university hospital. Using an observational controlled study, we tested 3 interventions: a desk sign mandating all visitors to use AHS, a free-standing AHS dispenser directly in front of a security desk, and a combination of a freestanding AHS dispenser and a sign. HHC was 0.52% at baseline and did not improve significantly when the desk sign was provided as a cue 0.67% (P = .753). However, HHC did improve significantly with use of the freestanding AHS dispenser (9.33%) and the sign and dispenser combination (11.67%) (P < .001 for all comparisons of dispenser alone and sign and dispenser with baseline and sign alone). The degree of improvement with the sign and dispenser combination over the dispenser was not statistically significant. Hospital visitors represent an important factor in infection prevention. A coordinated effort is needed to increase visitor HHC, including an evaluation of the AHS placement, education of visitors on the importance of HHC, and evaluation of corresponding changes in hand hygiene behavior. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  10. Simulated Tip Rub Testing of Low-Density Metal Foam

    NASA Technical Reports Server (NTRS)

    Bowman, Cheryl L.; Jones, Michael G.

    2009-01-01

    Preliminary acoustic studies have indicated that low-density, open-cell, metal foams may be suitable acoustic liner material for noise suppression in high by-pass engines. Metal foam response under simulated tip rub conditions was studied to assess whether its durability would be sufficient for the foam to serve both as a rub strip above the rotor as well as an acoustic treatment. Samples represented four metal alloys, nominal cell dimensions ranging from 60 to 120 cells per inch (cpi), and relative densities ranging from 3.4 to 10 percent. The resulting rubbed surfaces were relatively smooth and the open cell structure of the foam was not adversely affected. Sample relative density appeared to have significant influence on the forces induced by the rub event. Acoustic responses of various surface preparations were measured using a normal incidence tube. The results of this study indicate that the foam s open-cell structure was retained after rubbing and that the acoustic absorption spectra variation was minimal.

  11. Spill-Resistant Alkali-Metal-Vapor Dispenser

    NASA Technical Reports Server (NTRS)

    Klipstein, William

    2005-01-01

    A spill-resistant vessel has been developed for dispensing an alkali-metal vapor. Vapors of alkali metals (most commonly, cesium or rubidium, both of which melt at temperatures slightly above room temperature) are needed for atomic frequency standards, experiments in spectroscopy, and experiments in laser cooling. Although the present spill-resistant alkali-metal dispenser was originally intended for use in the low-gravity environment of outer space, it can also be used in normal Earth gravitation: indeed, its utility as a vapor source was confirmed by use of cesium in a ground apparatus. The vessel is made of copper. It consists of an assembly of cylinders and flanges, shown in the figure. The uppermost cylinder is a fill tube. Initially, the vessel is evacuated, the alkali metal charge is distilled into the bottom of the vessel, and then the fill tube is pinched closed to form a vacuum seal. The innermost cylinder serves as the outlet for the vapor, yet prevents spilling by protruding above the surface of the alkali metal, no matter which way or how far the vessel is tilted. In the event (unlikely in normal Earth gravitation) that any drops of molten alkali metal have been shaken loose by vibration and are floating freely, a mesh cap on top of the inner cylinder prevents the drops from drifting out with the vapor. Liquid containment of the equivalent of 1.2 grams of cesium was confirmed for all orientations with rubbing alcohol in one of the prototypes later used with cesium.

  12. A step-wise approach towards introduction of an alcohol based hand rub, and implementation of front line ownership- using a, rural, tertiary care hospital in central India as a model.

    PubMed

    Sharma, Megha; Joshi, Rita; Shah, Harshada; Macaden, Ragini; Lundborg, Cecilia Stålsby

    2015-04-29

    Appropriate hand hygiene is a gold standard to combat healthcare associated infections (HAIs). The World Health Organization (WHO) has recommended alcohol based hand rub (ABHR) as the most effective tool to maintain hand hygiene. In resource poor settings commercially available ABHR is not "economically accessible". The objectives of this study were to assess the acceptability of, and to build confidence for an in-house prepared (based on WHO guidelines) alcohol based hand rub among healthcare workers (HCWs) using a rural, tertiary care hospital in central India as an example. A series of activities were developed and conducted based on the Precede-Proceed model, the Trans Theoretical model of behaviour change, Front line ownership and Social marketing. A modified WHO-ABHR formulation, the 'test product' and 'WHO product evaluation form' were used for self assessment of acceptability of the 'test product'. Confidence building activities, as finger tip culture, visual portrayal method and handmade posters, were used in high-risk wards for HAIs, to build confidence for the 'test product' in removing transient flora from the hands. A locally developed feedback from was used to evaluate the impact of the activities conducted. Overall 183 HCWs were enrolled for the assessment of the 'test product' (130- doctors and 53 nurses). Out of these 83% (108/130) doctors and 94% (50/53) nurses were satisfied with the 'test product'. The confidence building activity was conducted with 116 participants (49 doctors). After single use of the 'test product', overall a significant reduction was observed for the CFUs on the blood agar plates (0.77 Log(10), p < 0.001). A complete reduction (100%) in colony forming units on incubated blood agar plates was seen for 13% (15/116) participants. Eighty two percent (95/116) participants expressed their confidence in the 'test product'. The self reported acceptance level for the 'test product' was high. The use of finger tip culture coupled

  13. Rub al Khali, Arabia

    NASA Image and Video Library

    2008-08-08

    NASA Terra spacecraft shows the Rub al Khali, one of the largest sand deserts in the world, encompassing most of the southern third of the Arabian Peninsula; it includes parts of Oman, United Arab Emirates, and Yemen.

  14. Promoting hand hygiene and prudent use of antimicrobials in long-term care facilities.

    PubMed

    Rummukainen, Maija; Jakobsson, Aino; Karppi, Pertti; Kautiainen, Hannu; Lyytikäinen, Outi

    2009-03-01

    A multidisciplinary team visited all long-term care facilities (n = 123) for elderly persons in the Central Finland health care district (population, 265,000) during 2004-2005. Use of alcohol-based hand rubs and ongoing systematic antimicrobials were assessed. Thereafter, regional guidelines for prudent use of antimicrobials were published. One year after the visits, a significant increase in the mean amount of alcohol-based hand rubs used was detected while usage of antimicrobials for the prevention of urinary tract reinfections had decreased.

  15. Modeling multi-scale resource selection for bear rub trees in northwestern Montana

    USGS Publications Warehouse

    Morgan Henderson, Matthew J.; Hebblewhite, Mark; Mitchell, Michael S.; Stetz, Jeffrey B.; Kendall, Katherine C.; Carlson, Ross T.

    2015-01-01

    Both black (Ursus americanus) and grizzly bears (U. arctos) are known to rub on trees and other objects, producing a network of repeatedly used and identifiable rub sites. In 2012, we used a resource selection function to evaluate hypothesized relationships between locations of 887 bear rubs in northwestern Montana, USA, and elevation, slope angle, density of open roads and distance from areas of heightened plant-productivity likely containing forage for bears. Slope and density of open roads were negatively correlated with rub presence. No other covariates were supported as explanatory variables. We also hypothesized that bear rubs would be more strongly associated with closed roads and developed trails than with game trails. The frequencies of bear rubs on 30 paired segments of developed tracks and game trails were not different. Our results suggest bear rubs may be associated with bear travel routes, and support their use as “random” sampling devices for non-invasive spatial capture–recapture population monitoring.

  16. Efficacy Evaluation of a non-contact automatic articulating paper dispenser in controlling articulating paper microbial contamination

    PubMed Central

    Li, Yajin; Chen, Litong; Yuan, Fusong; Li, Yugui; Zhou, Yongsheng; Sun, Yuchun

    2017-01-01

    This study is to quantitatively evaluate the efficacy of using a non-contact automatic articulating paper dispenser for reducing microbial articulating paper contamination. Articulating papers in four-handed mode, non-four-handed mode, and via an automatic articulating paper dispenser were evaluated. An adenosine triphosphate bioluminescence assay was used to quantitatively measure the relative light unit (RLU) values of the rest unused articulating papers in the same package to detect contamination at 4 time points, and triplicate examinations were performed for all three methods. The RLUs were recorded, compared, and evaluated. For four-handed mode (n = 36), the RLUs at the four time points were 2.44, 32.89, 37.89, and 27.22, with a satisfactory rate of 94%. The RLUs for non-four-handed mode (n = 36) were 2.22, 286.44, 299.44, and 493.56, with a satisfactory rate of 36%. The RLUs for using the automatic dispenser (n = 36) were all 0 with a satisfactory rate of 100%. The satisfactory rates were significantly different among three methods. No significant differences were observed in the satisfactory rates for the four time points samples. Contact by gloved hands can cause severe biological contamination of articulating paper. However, by using standard four-handed mode or a non-contact automatic articulating paper dispenser, contamination can be controlled. PMID:28466846

  17. The response of turbine engine rotors to interference rubs

    NASA Technical Reports Server (NTRS)

    Kascak, A. F.

    1980-01-01

    A method was developed for the direct integration of a rotor dynamics system experiencing a blade loss induced rotor rub. Both blade loss and rotor rub were simulated on a rotor typical of a small gas turbine. A small change in the coefficient of friction (from 0.1 to 0.2) caused the rotor to change from forward to backward whirl and to theoretically destroy itself in a few rotations. This method provides an analytical capability to study the susceptibility of rotors to rub induced backward whirl problems.

  18. Back to basics: hand hygiene and surgical hand antisepsis.

    PubMed

    Spruce, Lisa

    2013-11-01

    Health care-associated infections (HAIs) are a significant issue in the United States and throughout the world, but following proper hand hygiene practices is the most effective and least expensive way to prevent HAIs. Hand hygiene is inexpensive and protects patients and health care personnel alike. The four general types of hand hygiene that should be performed in the perioperative environment are washing hands that are visibly soiled, hand hygiene using alcohol-based products, surgical hand scrubs, and surgical hand scrubs using an alcohol-based surgical hand rub product. Barriers to proper hand hygiene may include not thinking about it, forgetting, skin irritation, a lack of role models, or a lack of a safety culture. One strategy for improving hand hygiene practices is monitoring hand hygiene as part of a quality improvement project, but the most important aspect for perioperative team members is to set an example for other team members by following proper hand hygiene practices and reminding each other to perform hand hygiene. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  19. Occurrence of heterotrophic and coliform bacteria in liquid hand soaps from bulk refillable dispensers in public facilities.

    PubMed

    Chattman, Marisa; Gerba, Sheri L; Maxwell, Charles P

    2011-03-01

    The goal of the study discussed in this article was to determine the occurrence of heterotrophic and coliform bacteria in liquid soap from bulk refillable dispensers, obtained from restrooms in a variety of public facilities. A total of 541 samples was collected from five U.S. cities. Liquid soap from dispensers in public areas was found to contain heterotrophic and coliform bacterial numbers averaging more than 106 CFU/mL in 24.8% of the dispensers.

  20. Effect of Resin-modified Glass Ionomer Cement Dispensing/Mixing Methods on Mechanical Properties.

    PubMed

    Sulaiman, T A; Abdulmajeed, A A; Altitinchi, A; Ahmed, S N; Donovan, T E

    2018-03-23

    Resin-modified glass ionomer cements (RMGIs) are often used for luting indirect restorations. Hand-mixing traditional cements demands significant time and may be technique sensitive. Efforts have been made by manufacturers to introduce the same cement using different dispensing/mixing methods. It is not known what effects these changes may have on the mechanical properties of the dental cement. The purpose of this study was to evaluate the mechanical properties (diametral tensile strength [DTS], compressive strength [CS], and fracture toughness [FT]) of RMGIs with different dispensing/mixing systems. The RMGI specimens (n=14)-RelyX Luting (hand mix), RelyX Luting Plus (clicker-hand mix), RelyX Luting Plus (automix) (3M ESPE), GC Fuji PLUS (capsule-automix), and GC FujiCEM 2 (automix) (GC)-were prepared for each mechanical test and examined after thermocycling (n=7/subgroup) for 20,000 cycles to the following: DTS, CS (ISO 9917-1) and FT (ISO standard 6872; Single-edge V-notched beam method). Specimens were mounted and loaded with a universal testing machine until failure occurred. Two-/one-way analysis of variance followed by Tukey honestly significantly different post hoc test was used to analyze data for statistical significance ( p<0.05). The interaction effect of both dispensing/mixing method and thermocycling was significant only for the CS test of the GC group ( p<0.05). The different dispensing/mixing methods had no effect on the DTS of the tested cements. The CS of GC Fuji PLUS was significantly higher than that of the automix version ( p<0.05). The FT decreased significantly when switching from RelyX (hand mix) to RelyX Luting Plus (clicker-hand mix) and to RelyX Luting Plus (automix) ( p<0.05). Except in the case of the DTS of the GC group and the CS of GC Fuji PLUS, thermocycling had a significant effect reducing the mechanical properties of the RMGI cements ( p<0.05). Introducing alternative dispensing/mixing methods for mixing RMGIs to reduce time and

  1. Field experiences with rub induced instabilities in turbomachinery

    NASA Technical Reports Server (NTRS)

    Goggin, D. G.

    1982-01-01

    Rotordynamic instability problems are not uncommon in high speed industrial turbomachinery. One type of the many destabilizing forces that can occur is caused by a rub between the stationary and rotating parts. Descriptions are given of several cases of rub induced instabilities. Included in the descriptions are the conditions at onset, the whirl frequency and direction, and the steps taken to eliminate the problem.

  2. Acoustic emissions diagnosis of rotor-stator rubs using the KS statistic

    NASA Astrophysics Data System (ADS)

    Hall, L. D.; Mba, D.

    2004-07-01

    Acoustic emission (AE) measurement at the bearings of rotating machinery has become a useful tool for diagnosing incipient fault conditions. In particular, AE can be used to detect unwanted intermittent or partial rubbing between a rotating central shaft and surrounding stationary components. This is a particular problem encountered in turbines used for power generation. For successful fault diagnosis, it is important to adopt AE signal analysis techniques capable of distinguishing between various types of rub mechanisms. It is also useful to develop techniques for inferring information such as the severity of rubbing or the type of seal material making contact on the shaft. It is proposed that modelling the cumulative distribution function of rub-induced AE signals with respect to appropriate theoretical distributions, and quantifying the goodness of fit with the Kolmogorov-Smirnov (KS) statistic, offers a suitable signal feature for diagnosis. This paper demonstrates the successful use of the KS feature for discriminating different classes of shaft-seal rubbing.

  3. The Effects of Surgical Hand Scrubbing Protocols on Skin Integrity and Surgical Site Infection Rates: A Systematic Review.

    PubMed

    Liu, Liang Qin; Mehigan, Sinead

    2016-05-01

    This systematic review aimed to critically appraise and synthesize updated evidence regarding the effect of surgical-scrub techniques on skin integrity and the incidence of surgical site infections. Databases searched include the Cumulative Index to Nursing and Allied Health Literature, MEDLINE, Embase, and Cochrane Central. Our review was limited to eight peer-reviewed, randomized controlled trials and two nonrandomized controlled trials published in English from 1990 to 2015. Comparison models included traditional hand scrubbing with chlorhexidine gluconate or povidone-iodine against alcohol-based hand rubbing, scrubbing with a brush versus without a brush, and detergent-based antiseptics alone versus antiseptics incorporating alcohol solutions. Evidence showed that hand rubbing techniques are as effective as traditional scrubbing and seem to be better tolerated. Hand rubbing appears to cause less skin damage than traditional scrub protocols, and scrub personnel tolerated brushless techniques better than scrubbing using a brush. Copyright © 2016 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  4. Bacterial Hand Contamination and Transfer after Use of Contaminated Bulk-Soap-Refillable Dispensers▿†

    PubMed Central

    Zapka, Carrie A.; Campbell, Esther J.; Maxwell, Sheri L.; Gerba, Charles P.; Dolan, Michael J.; Arbogast, James W.; Macinga, David R.

    2011-01-01

    Bulk-soap-refillable dispensers are prone to extrinsic bacterial contamination, and recent studies demonstrated that approximately one in four dispensers in public restrooms are contaminated. The purpose of this study was to quantify bacterial hand contamination and transfer after use of contaminated soap under controlled laboratory and in-use conditions in a community setting. Under laboratory conditions using liquid soap experimentally contaminated with 7.51 log10 CFU/ml of Serratia marcescens, an average of 5.28 log10 CFU remained on each hand after washing, and 2.23 log10 CFU was transferred to an agar surface. In an elementary-school-based field study, Gram-negative bacteria on the hands of students and staff increased by 1.42 log10 CFU per hand (26-fold) after washing with soap from contaminated bulk-soap-refillable dispensers. In contrast, washing with soap from dispensers with sealed refills significantly reduced bacteria on hands by 0.30 log10 CFU per hand (2-fold). Additionally, the mean number of Gram-negative bacteria transferred to surfaces after washing with soap from dispensers with sealed-soap refills (0.06 log10 CFU) was significantly lower than the mean number after washing with contaminated bulk-soap-refillable dispensers (0.74 log10 CFU; P < 0.01). Finally, significantly higher levels of Gram-negative bacteria were recovered from students (2.82 log10 CFU per hand) than were recovered from staff (2.22 log10 CFU per hand) after washing with contaminated bulk soap (P < 0.01). These results demonstrate that washing with contaminated soap from bulk-soap-refillable dispensers can increase the number of opportunistic pathogens on the hands and may play a role in the transmission of bacteria in public settings. PMID:21421792

  5. Behaviour modification in the management of chronic habits of abnormal eye rubbing.

    PubMed

    McMonnies, Charles W

    2009-04-01

    To describe how and why many keratoconus patients do not comply with strong advice to control chronic habits of abnormal rubbing. To outline a behaviour modification approach for controlling chronic habits of abnormal rubbing. Common reasons for chronic habits of abnormal rubbing have been reviewed as a basis for specifying a behavioural modification approach to habit reversal. The methods described are organized into the classic behavioural modification structure of: (1) habit awareness, (2) competing responses, (3) development of motivation, and (4) social support. This structure is supported by the application of social influence principles to achieve optimum compliance. The use of take-home written information in the form of an Abnormal Rubbing Guide is the basis for the development of motivation. Family social support is based upon a widening of the responsibility for avoiding eye rubbing to all family members. Some patients will need minimal application of these principles with patient education being sufficient intervention to achieve habit reversal. For patients with strong provocation to rubbing and/or by having a well established rubbing habit, a greater exposure to the habit reversal program described is indicated. Successful habit reversal may slow the rate of ectasia progression. Prophylactic application of the methods described for patients who are at risk for developing keratoconus, or post-laser assisted in situ keratomileusis keratectasia, may show that some forms of keratectasia are preventable.

  6. Practice of skin protection and skin care among German surgeons and influence on the efficacy of surgical hand disinfection and surgical glove perforation

    PubMed Central

    2014-01-01

    Background Surgical hand rub and healthy skin are basic requirements to prevent surgical site infections. Nevertheless, there is little knowledge about the current practice of skin protection and/or skin care products (SP/SC) using among surgeons as well as a lack of data pertaining to the influence of SP/SC on the antimicrobial efficacy of surgical hand rub. Methods A 10 weeks-survey among German surgeons as well as an experimental crossover study involving 26 participants were conducted. The immediate and sustainable efficacy (IE/SE) of surgical hand rub and participants’ hand moisture were measured after an 8-day usage of SP/SC, as well as the influence on micro-perforations on surgical gloves. Results The questionnaire was available to 16,000 German surgeons. Thereof, 1,771 surgeons accessed the questionnaire, representing a total participation rate of 11%. As 19% (n = 338) of questionnaires were incomplete, a total of 1,433 completed questionnaires were available for further analysis. More than 75% of the participants stated not to use any SP/SC, yet, almost 50% suffered from skin irritation or discomfort. Only 5% used SP/SC at the beginning of their shift. 10% refused to use SP/SC because of concerns that SP/SC may reduce the antimicrobial efficacy of surgical hand rub. After usage of SP/SC over 8-days, skin moisture was significantly higher (P < 0.001), whereas no significant influence on the antimicrobial efficacy of surgical hand rub was observed (IE: P = 0.135; SP: P = 0.681). Micro-perforations were detected in 8/52 surgical gloves (15%), with no statistical significant difference between SP/SC users (n = 2/26; 8%) and non-users (n = 6/26; 23%; P = 0.249). Conclusions Following the results of this largest questionnaire base survey among German surgeons on skin care, there is a need to educate and inform surgeons on the correct application and the concept of SP/SC strategies. In the present study, the combination of selected

  7. Medicare and Medicaid programs; fire safety requirements for certain health care facilities; amendment. Final rule.

    PubMed

    2006-09-22

    This final rule adopts the substance of the April 15, 2004 tentative interim amendment (TIA) 00-1 (101), Alcohol Based Hand Rub Solutions, an amendment to the 2000 edition of the Life Safety Code, published by the National Fire Protection Association (NFPA). This amendment allows certain health care facilities to place alcohol-based hand rub dispensers in egress corridors under specified conditions. This final rule also requires that nursing facilities at least install battery-operated single station smoke alarms in resident rooms and common areas if they are not fully sprinklered or they do not have system-based smoke detectors in those areas. Finally, this final rule confirms as final the provisions of the March 25, 2005 interim final rule with changes and responds to public comments on that rule.

  8. Multicenter intervention program to increase adherence to hand hygiene recommendations and glove use and to reduce the incidence of antimicrobial resistance.

    PubMed

    Trick, William E; Vernon, Michael O; Welbel, Sharon F; Demarais, Patricia; Hayden, Mary K; Weinstein, Robert A

    2007-01-01

    To determine whether a multimodal intervention could improve adherence to hand hygiene and glove use recommendations and decrease the incidence of antimicrobial resistance in different types of healthcare facilities. Prospective, observational study performed from October 1, 1999, through December 31, 2002. We monitored adherence to hand hygiene and glove use recommendations and the incidence of antimicrobial-resistant bacteria among isolates from clinical cultures. We evaluated trends in and predictors for adherence and preferential use of alcohol-based hand rubs, using multivariable analyses. Three intervention hospitals (a 660-bed acute and long-term care hospital, a 120-bed community hospital, and a 600-bed public teaching hospital) and a control hospital (a 700-bed university teaching hospital).Intervention. At the intervention hospitals, we introduced or increased the availability of alcohol-based hand rub, initiated an interactive education program, and developed a poster campaign; at the control hospital, we only increased the availability of alcohol-based hand rub. We observed 6,948 hand hygiene opportunities. The frequency of hand hygiene performance or glove use significantly increased during the study period at the intervention hospitals but not at the control hospital; the maximum quarterly frequency of hand hygiene performance or glove use at intervention hospitals (74%, 80%, and 77%) was higher than that at the control hospital (59%). By multivariable analysis, preferential use of alcohol-based hand rubs rather than soap and water for hand hygiene was more likely among workers at intervention hospitals compared with nonintervention hospitals (adjusted odds ratio, 4.6 [95% confidence interval, 3.3-6.4]) and more likely among physicians (adjusted odds ratio, 1.4 [95% confidence interval, 1.2-1.8]) than among nurses at intervention hospitals. A significantly reduced incidence of antimicrobial-resistant bacteria among isolates from clinical culture was

  9. The Snowball Blizzard Incident: A Reality Rub Life Space Interview.

    ERIC Educational Resources Information Center

    Long, Nicholas J.; Pinciotti, Dennis

    1992-01-01

    Focuses on Reality Rub Interview, one type of Life Space Interview (LSI), effective intervention strategy for use during crisis work with troubled students. Presents actual Reality Rub Interview, used with students who have "social blindness, social myopia, and tunnel vision" and who, when upset, misinterpret words and behaviors of…

  10. The Role of RUB (related to ubiquitin) Family of Proteins in the Hormone Response. Final Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Callis, Judy

    2013-03-22

    The Rub pathway is a conserved protein modification pathway. RUB (called Rubp1 in budding yeast, Nedd8 in animals and RUB in plants) is a ubiquitin-like 76-amino acid protein. It covalently attaches to protein using an enzymatic machinery analogous to the enzymes that attach ubiquitin to its substrate proteins. However, the nature of the complement of Rub-modified proteins in organisms was not clear. From bioinformatics analyses, one can identify a Rub activating enzymes and Rub conjugating enzymes. However, in many cases, their biochemical properties were not described. In DOE-funded work, we made major advances in our understanding of the Rub pathwaymore » in yeast and plants, work that is applicable to other organisms as well. There is a multi-subunit enzyme called SCF in all eukaryotes. The SCF consists of several subunits that serve as a scaffold (the cullin, SKP and RBX subunits) and one subunit that interacts with the substrate. This cullin protein (called Cdc53p in yeast and CULLIN 1 in plants and animals) was a known Rub target. In this work, we identified additional Rub targets in yeast as the other cullin-like proteins Cul3p and Rtt101p. Additionally we described the conservation of the Rub pathway because plant RUB1 can conjugated to yeast Cdc53p- in yeast. In the model plant Arabidopsis thaliana, we characterized the Rub activating enzymes and showed that they are not biochemically equivalent. We also showed that the Rub pathway is essential in plants and characterized plants with reduced levels of rub proteins. These plants are affected in multiple developmental processes. We discovered that they over-produce ethylene as dark-grown seedlings. We characterized a mutant allele of CULLIN1 in Arabidopsis with impaired interaction with RBX and showed that it is unstable in vivo. We used our knowledge of monitoring protein degradation to map the degradation determinants in a plant transcription factor. Finally, we took a mass spectrometric approach to

  11. Small-Portion Water Dispenser

    NASA Technical Reports Server (NTRS)

    Joerns, J. C.

    1986-01-01

    Pressure regulated and flow timed to control amount dispensed. Dispenser provides measured amount of water for reconstituting dehydrated foods and beverages. Dispenser holds food or beverage package while being filled with either cold or room-temperature water. Other uses might include dispensing of fluids or medicine. Pressure regulator in dispenser reduces varying pressure of water supply to constant pressure. Electronic timer stops flow after predetermined length of time. Timed flow at regulated pressure ensures controlled volume of water dispensed.

  12. Hand Hygiene Practices Among Indian Medical Undergraduates: A Questionnaire-Based Survey

    PubMed Central

    Modi, Pranav D; Solanki, Rajavi; Modi, Janhavi; Chandramani, Srinath; Gill, Niharika

    2017-01-01

    Background and objectives To prevent the spread of infections in all healthcare settings, hand hygiene must be routinely practiced. Appropriate hand hygiene techniques can go a long way in reducing nosocomial infections, cross-transmission of microorganisms and the risk of occupational exposure to infectious diseases. World Health Organisation (WHO) has taken an incredible approach called “My Five Moments for Hand Hygiene" which defines the key moments when health-care workers should perform hand hygiene. We thus carried out a survey to assess knowledge of hand hygiene practices among undergraduate medical students.  Materials and methods A cross-sectional survey was conducted among 523 Indian medical undergraduates. The questionnaire used was adapted from the WHO hand hygiene knowledge questionnaire for health-care workers and was distributed both, in print and online formats. The response to each question was examined using percentages. Results Nearly 57% (n=298) of medical students who participated in this study did not receive any formal training in hand hygiene. Only 27% (n=141) students knew that the most frequent source of germs responsible for health-care associated infections were the germs already present on or within the patient. Nearly 68.6% (n= 359) students were unaware of the sequence of hand washing and hand rubbing. Although 71.9% (n=376 ) students claimed that they use an alcohol-based hand rub routinely, only 36.1% (n=189 ) students knew the time required for a hand rub to kill the germs on the hands. Overall hand hygiene knowledge was low in 6.9% (n=36), moderate in 80.9% (n=423) and good in 12.2% (n=23) of respondents.  Conclusions The awareness about hand hygiene practices among medical students is low. Nearly 57% (n=298) of the respondents never received any formal training in hand hygiene throughout their course of medical undergraduate study. To prevent the spread of infections in healthcare settings, medical students should be given

  13. Degraded Chinese rubbing images thresholding based on local first-order statistics

    NASA Astrophysics Data System (ADS)

    Wang, Fang; Hou, Ling-Ying; Huang, Han

    2017-06-01

    It is a necessary step for Chinese character segmentation from degraded document images in Optical Character Recognizer (OCR); however, it is challenging due to various kinds of noising in such an image. In this paper, we present three local first-order statistics method that had been adaptive thresholding for segmenting text and non-text of Chinese rubbing image. Both visual inspection and numerically investigate for the segmentation results of rubbing image had been obtained. In experiments, it obtained better results than classical techniques in the binarization of real Chinese rubbing image and PHIBD 2012 datasets.

  14. A simple low-cost of liquid I-131 dispenser for routine radiopharmaceutical dispensing at nuclear medicine department, Institut Kanser Negara

    NASA Astrophysics Data System (ADS)

    Said, M. A.; Ashhar, Z. N.; Suhaimi, N. E. F.; Zainon, R.

    2016-01-01

    In routine radiopharmaceutical Iodine-131 (131I) dispensing, the amount of radiation dose received by the personnel depends on the distance between the personnel and the source, the time spent manipulating the source and the amount of shielding used to reduce the dose rate from the source. The novel iRAD-I131 dispenser using recycle 131I liquid lead pot will lead into low cost production, less maintenance and low dose received by the personnel that prepared the 131I. The new fabricated of low cost 131I dispenser was tested and the dose received by personnel were evaluated. The body of lead material is made from 2.5 cm lead shielded coated with epoxy paint to absorb the radiation dose up to 7.4 GBq of 131 I. The lead pot was supported with two stainless steel rod. The Optically Stimulated Luminescence (OSL) nanodot was used in this study to measure the dose rate at both extremities for every personnel who prepared the 131I. Each OSL nanodot was attached at the fingertip. Three different personnel (experienced between one to ten years above in preparing the radiopharmaceuticals) were participated in this study. The average equivalent dose at right and left hand were 122.694 ± 121.637 µSv/GBq and 77.281 ± 62.146 µSv/GBq respectively. This study found that the dose exposure received using iRAD-I131 was less up to seven times compared to the conventional method. The comparison of experimental data using iRAD-I131 and established radiopharmaceutical dispenser was also discussed. The innovation of 131I dispenser is highly recommended in a small radiopharmaceutical facility with limited budget. The novel iRAD-I131 enables implementation of higher output liquid dispensing with low radiation dose to the personnel.

  15. Rotor vibration caused by external excitation and rub

    NASA Technical Reports Server (NTRS)

    Matsushita, O.; Takagi, M.; Kikuchi, K.; Kaga, M.

    1982-01-01

    For turbomachinery with low natural frequencies, considerations have been recently required for rotor vibrations caused by external forces except unbalance one, such as foundation motion, seismic wave, rub and so forth. Such a forced vibration is investigated analytically and experimentally in the present paper. Vibrations in a rotor-bearing system under a harmonic excitation are analyzed by the modal technique in the case of a linear system including gyroscopic effect. For a nonlinear system a new and powerful quasi-modal technique is developed and applied to the vibration caused by rub.

  16. Combined use of alcohol hand rub and gloves reduces the incidence of late onset infection in very low birthweight infants.

    PubMed

    Ng, P C; Wong, H L; Lyon, D J; So, K W; Liu, F; Lam, R K Y; Wong, E; Cheng, A F B; Fok, T F

    2004-07-01

    To assess the incidence of late onset (> 72 hours) infection and necrotising enterocolitis (NEC) in very low birthweight (VLBW) infants in two 36 month periods using two hand hygiene protocols: conventional handwashing (HW; first 36 month period); an alcohol hand rub and gloves technique (HR; second 36 month period). VLBW infants admitted to the neonatal intensive care unit during the period December 1993-November 1999 were eligible. A new hand hygiene protocol using alcohol handrub and gloves was introduced in December 1996. Each patient's case record was reviewed retrospectively by two independent investigators using a standard data collection form. The incidence of NEC and systemic infections, including bacterial or fungal septicaemia, meningitis, and peritonitis, in the two periods were compared. The HW and HR groups contained 161 and 176 VLBW infants respectively. The incidence of late onset systemic infection decreased from 13.5 to 4.8 episodes (including NEC)/1000 patient days after introduction of the HR regimen, representing a 2.8-fold reduction. Similarly, the incidence of Gram positive, Gram negative, and fungal infections decreased 2.5-fold, 2.6-fold, and 7-fold respectively. There was also a significant reduction in the incidence of NEC in the HR group (p < 0.0001). Subgroup analysis revealed that the incidence of methicillin resistant Staphylococcus aureus (MRSA) septicaemia was significantly decreased in the second 36 month period (p = 0.048). The clinical data suggest that infants in the HW group had significantly earlier onset of sepsis (p < 0.05) and required oxygen supplementation for longer (p < 0.05) than those in the HR group. Significantly more VLBW infants were discharged from the neonatal intensive care unit without ever being infected (p < 0.0001), and also significantly fewer infants had more than one episode of infection in the HR group (p < 0.0001). The introduction of the HR protocol was associated with a 2.8-fold reduction in the

  17. Anti-bacterial efficacy of alcoholic hand rubs in the Kenyan market, 2015.

    PubMed

    Ochwoto, Missiani; Muita, Lucy; Talaam, Keith; Wanjala, Cecilia; Ogeto, Frank; Wachira, Faith; Osman, Saida; Kimotho, James; Ndegwa, Linus

    2017-01-01

    Hand hygiene is known to be effective in preventing hospital and community-acquired infections. The increasing number of hand sanitizer brands in Kenyan hospitals and consumer outlets is of concern. Thus the main aim of this study was to evaluate the anti-bacterial efficacy and organoleptic properties of these hand sanitizers in Kenya. This was an experimental, laboratory-based study of 14 different brands of hand sanitizers (coded HS1-14) available in various retail outlets and hospitals in Kenya. Efficacy was evaluated using standard non-pathogenic Escherichia coli (ATCC 25922), Staphylococcus aureus (ATCC 25923) and Pseudomonas aeruginosa (ATCC 27853) as per the European Standard (EN). The logarithmic reduction factors (RF) were assessed at baseline and after treatment, and log reduction then calculated. Ten and 25 healthy volunteers participated in the efficacy and organoleptic studies respectively. Four (28.6%) hand sanitizers (HS12, HS9, HS13 and HS14) showed a 5.9 reduction factor on all the three bacteria strains. Seven (50%) hand sanitizers had efficacies of <3 against all the three bacteria strains used. Efficacy on E. Coli was higher compared to the other pathogens. Three hand sanitizers were efficacious on one of the pathogens and not the other. In terms of organoleptic properties, gel-based formulations were rated far higher than the liquid based formulations brands. Fifty percent (50%) of the selected hand sanitizers in the Kenyan market have efficacy that falls below the World Health Organization (WHO) and DIN EN 1500:2013. Of the 14 hand sanitizers found in the Kenyan market, only four showed efficacies that were comparable to the WHO-formulation. There is a need to evaluate how many of these products with <3 efficacy that have been incorporated into the health system for hand hygiene and the country's policy on regulations on their usage.

  18. Rub tolerant shroud

    NASA Technical Reports Server (NTRS)

    Lenahan, Dean T. (Inventor); Gay, Jr., Charles H. (Inventor)

    1985-01-01

    A seal structure between first and second relatively moveable members for preventing gas flow in the space between the members and transverse to their general direction of motion is disclosed. The seal structure includes a plurality of substantially parallel strips within 30.degree. of normal to the radial plane generally containing these first and second relatively moveable members. The strips are thin and closely spaced and arranged so that one strip edge is attached to the first member and another edge is free to resiliently deflect when in rubbing contact with the second member.

  19. Hand hygiene in rural Indonesian healthcare workers: barriers beyond sinks, hand rubs and in-service training.

    PubMed

    Marjadi, B; McLaws, M-L

    2010-11-01

    Few attempts to increase healthcare workers' hand hygiene compliance have included an in-depth analysis of the social and behavioural context in which hand hygiene is not undertaken. We used a mixed method approach to explore hand hygiene barriers in rural Indonesian healthcare facilities to develop a resource-appropriate adoption of international guidelines. Two hospitals and eight clinics (private and public) in a rural Indonesian district were studied for three months each. Hand hygiene compliance was covertly observed for two shifts each in three adult wards at two hospitals. Qualitative data were collected from direct observation, focus group discussions and semistructured in-depth and informal interviews within healthcare facilities and the community. Major barriers to compliance included longstanding water scarcity, tolerance of dirtiness by the community and the healthcare organisational culture. Hand hygiene compliance was poor (20%; 57/281; 95% CI: 16-25%) and was more likely to be undertaken after patient contact (34% after-patient contact vs 5% before-patient contact, P<0.001) and 'inherent' opportunities associated with contacts perceived to be dirty (49% 'inherent' vs 11% 'elective' opportunities associated with clean contacts, P<0.001). Clinicians frequently touched patients without hand hygiene, and some clinicians avoided touching patients altogether. The provision of clean soap and water and in-service training will not overcome strong social and behavioural barriers unless interventions focus on long term community education and managerial commitment to the provision of supportive working conditions. Copyright © 2010 The Hospital Infection Society. All rights reserved.

  20. Effect of eye rubbing on signs and symptoms of allergic conjunctivitis in cat-sensitive individuals.

    PubMed

    Raizman, M B; Rothman, J S; Maroun, F; Rand, W M

    2000-12-01

    To evaluate the effect of eye rubbing on signs and symptoms of allergic conjunctivitis in cat-sensitive individuals. Two prospective, nonrandomized comparative studies. Thirteen patients in the first study and 20 patients in the second study with a documented history of acute allergic conjunctivitis induced by exposure to cats were enrolled. In the first trial, all patients had one eye rubbed 15 times by the investigator without exposure to airborne allergens. Both eyes were evaluated after 5, 15, 30, and 60 minutes using subject questionnaires and slit-lamp examination. At least 1 week later, each patient was exposed to cat dander for 75 minutes; 15 minutes after entering the cat room, each patient had one eye rubbed 15 times by the examiner. Subjects' eyes were then evaluated using questionnaires and slit-lamp examination. In the second trial, the visits were identical to the first trial, except that the rubbed eye in each visit was rubbed 20 times and with more force, and that patients wore masks during exposure to cat dander. In both studies, the difference between patients' rubbed and nonrubbed eyes with respect to ocular itching, chemosis, and hyperemia was noted 5, 15, 30, and 60 minutes after controlled eye rubbing. Without exposure to the cat room, rubbed eyes exhibited increased itching at 5 minutes in both studies and at 15 minutes in the second study (P < 0.05), increased chemosis at 5 and 15 minutes in the second study (P < 0.05), and increased hyperemia at 5 minutes in the second study (P < 0.05) compared with nonrubbed eyes. During exposure to cat dander, rubbed eyes consistently exhibited increased itching at 5, 15, and 30 minutes in the first and second study as well as at 60 minutes in the second study compared with nonrubbed eyes. Furthermore, during exposure to cat dander, rubbed eyes consistently exhibited increased chemosis at 5 and 15 minutes (P < 0.05) and increased hyperemia at 5, 15, and 30 minutes (P < 0.05) in the second study compared

  1. Potable water dispenser

    NASA Technical Reports Server (NTRS)

    Cunningham, H. R. (Inventor)

    1973-01-01

    A dispenser particularly suited for use in dispensing potable water into food and beverage reconstitution bags is described. The dispenser is characterized by an expansible chamber, selectively adjustable stop means for varying the maximum dimensions, a rotary valve, and a linear valve coupled in a cooperating relation for delivering potable water to and from the chamber.

  2. Light and short arc rubs in rotating machines: Experimental tests and modelling

    NASA Astrophysics Data System (ADS)

    Pennacchi, P.; Bachschmid, N.; Tanzi, E.

    2009-10-01

    Rotor-to-stator rub is a non-linear phenomenon which has been analyzed many times in rotordynamics literature, but very often these studies are devoted simply to highlight non-linearities, using very simple rotors, rather than to present reliable models. However, rotor-to-stator rub is actually one of the most common faults during the operation of rotating machinery. The frequency of its occurrence is increasing due to the trend of reducing the radial clearance between the seal and the rotor in modern turbine units, pumps and compressors in order to increase efficiency. Often the rub occurs between rotor and seals and the analysis of the phenomenon cannot set aside the consideration of the different relative stiffness. This paper presents some experimental results obtained by means of a test rig in which rub conditions of real machines are reproduced. In particular short arc rubs are considered and the shaft is stiffer than the obstacle. Then a model, suitable to be employed for real rotating machinery, is presented and the simulations obtained are compared with the experimental results. The model is able to reproduce the behaviour of the test rig.

  3. Improving hand hygiene in a paediatric hospital: a multimodal quality improvement approach.

    PubMed

    Jamal, Ahmed; O'Grady, G; Harnett, E; Dalton, D; Andresen, D

    2012-02-01

    Effective hand hygiene has long been recognised as an important way to reduce the transmission of bacterial and viral pathogens in healthcare settings. However, many studies have shown that adherence to hand hygiene remains low, and improvement efforts have often not delivered sustainable results. The Children's Hospital at Westmead is the largest tertiary paediatric hospital in Sydney, Australia. The hospital participated in a state-wide 'Clean hands save lives' campaign which was initiated in 2006. Strong leadership, good stakeholder engagement, readily accessible alcohol-based hand rub at the point of patient care, a multifaceted education programme, monitoring of staff, adherence to recommended hand hygiene practices and contemporaneous feedback of performance data have significantly improved and maintained compliance with hand hygiene. Hand hygiene compliance has increased from 23% in 2006 to 87% in 2011 (p<0.001). Sustained improvement in compliance with hand hygiene has been evident in the last 4 years. A decline in a set of hospital-acquired infections (including rotavirus, multiresistant organism transmission, and nosocomial bacteraemia) has also been noted as hand hygiene rates have improved. Monthly usage of alcohol-based hand rub has increased from 16 litres/1000 bed days to 51 litres/1000 bed days during this same period. This project has delivered sustained improvement in hand hygiene compliance by establishing a framework of multimodal evidence-based strategies.

  4. Three years of national hand hygiene campaign in Germany: what are the key conclusions for clinical practice?

    PubMed

    Reichardt, C; Königer, D; Bunte-Schönberger, K; van der Linden, P; Mönch, N; Schwab, F; Behnke, M; Gastmeier, P

    2013-02-01

    The World Health Organization (WHO) started the 'Clean Care is Safer Care' campaign in 2005. Since then, more than 120 countries have pledged to improve hand hygiene as a keystone of their national or subnational healthcare-associated infection prevention programmes. Thirty-eight countries have implemented national campaigns. Germany started a national campaign to improve hand hygiene compliance on 1 January 2008. The campaign, 'AKTION Saubere Hände', is funded by the German Ministry of Health and was initiated by the National Reference Centre for the Surveillance of Nosocomial Infections, the Society for Quality Management in Health Care and the German Coalition for Patient Safety. The campaign is designed as a multi-modal campaign based on the WHO implementation strategy. Since the end of 2010, more than 700 healthcare institutions have been actively participating in the campaign, among which are 28 university hospitals. Voluntarily participating hospitals have to implement the following measures: active support by hospital administrators of local campaign implementation, participation in a one-day introductory course, education of healthcare workers at least once a year, measurement of alcohol-based hand-rub consumption (AHC) and feedback on resulting data, implementation of the WHO 'My Five Moments for Hand Hygiene' model, increase in hand-rub availability, participation in national hand hygiene day at least every two years, and participation in national campaign network workshops at least once every two years. Observational studies to measure hand hygiene compliance are optional. Overall, there has been a significant increase of 11% in hand hygiene compliance in 62 hospitals that observed compliance before and after intervention. A total of 129 hospitals provided AHC data for three years and achieved an overall increase of 30.7%. The availability of alcohol-based hand rub increased from 86.8% to > 100% in intensive care units and from 63.6% to 91.3% in non

  5. Effect of rubbing on the in vitro skin permeation of diclofenac-diethylamine 1.16% gel.

    PubMed

    Hasler-Nguyen, Nathalie; Fotopoulos, Grigorios

    2012-06-21

    Rubbing a topical NSAID (non steroidal anti-inflammatory drug) on the skin may increase local drug permeation, affecting its distribution to the site of pain and inflammation. The present study evaluates this hypothesis, by assessing in vitro the effect on skin permeation of applying diclofenac-dieythylamine 1.16% gel with or without rubbing. A single dose of 5 mg/cm2 diclofenac-diethylamine 1.16% gel was applied on excised human skin mounted in Franz-type diffusion cells without or with rubbing for 45 s. Drug penetration into the skin layers was determined after 1 h using the tape stripping technique. In vitro cutaneous permeation into the receptor fluid of the diffusion chamber was measured up to 24 h. Skin electrical resistance was also recorded. Application of diclofenac-diethylamine 1.16% gel with rubbing resulted to a 5-fold higher flux of diclofenac through the skin than when applied without rubbing at 8 h (P = 0.04). Skin rubbing for 45 s decreased by 2-fold skin electrical resistance when compared to the standard application. Application of diclofenac-diethylamine 1.16% gel with rubbing tended to result in higher accumulation in the stripped skin vs. the superficial skin layers when applied without rubbing (P = 0.2). These results suggest that rubbing may alter the superficial skin layer resulting in a transient faster initial diffusion of topically applied diclofenac through the stratum corneum into the deeper skin layer of the dermis to the tissue target.

  6. Effect of rubbing on the in vitro skin permeation of diclofenac-diethylamine 1.16% gel

    PubMed Central

    2012-01-01

    Background Rubbing a topical NSAID (non steroidal anti-inflammatory drug) on the skin may increase local drug permeation, affecting its distribution to the site of pain and inflammation. The present study evaluates this hypothesis, by assessing in vitro the effect on skin permeation of applying diclofenac-dieythylamine 1.16% gel with or without rubbing. Methods A single dose of 5 mg/cm2 diclofenac-diethylamine 1.16% gel was applied on excised human skin mounted in Franz-type diffusion cells without or with rubbing for 45 s. Drug penetration into the skin layers was determined after 1 h using the tape stripping technique. In vitro cutaneous permeation into the receptor fluid of the diffusion chamber was measured up to 24 h. Skin electrical resistance was also recorded. Results Application of diclofenac-diethylamine 1.16% gel with rubbing resulted to a 5-fold higher flux of diclofenac through the skin than when applied without rubbing at 8 h (P = 0.04). Skin rubbing for 45 s decreased by 2-fold skin electrical resistance when compared to the standard application. Application of diclofenac-diethylamine 1.16% gel with rubbing tended to result in higher accumulation in the stripped skin vs. the superficial skin layers when applied without rubbing (P = 0.2). Conclusion These results suggest that rubbing may alter the superficial skin layer resulting in a transient faster initial diffusion of topically applied diclofenac through the stratum corneum into the deeper skin layer of the dermis to the tissue target. PMID:22720797

  7. Hand hygiene in the nursery during diaper changing.

    PubMed

    Phang, Koh Ni; Maznin, Nur Liyanna; Yip, Wai Kin

    2012-12-01

    This project aimed to improve hand hygiene practice during diaper changing among nurses working in the nursery. This project was conducted in one of the nurseries in a 935-bed acute care hospital with a sample of 15 nurses. A pre- and post-intervention audit was conducted utilising the Joanna Briggs Institute Practical Application of Clinical Evidence System and Getting Research into Practice module. A revised written workflow, which specified the occasions and process for hand hygiene during diaper changing, was introduced. Modifications to the baby bassinets and nursery were made after barriers to good hand hygiene were identified. The project was carried out over 4 months, from March to June 2011. The post-intervention audit results show an improvement in performing hand washing after changing diapers (20%) and performing the correct steps of hand rubbing (25%). However, the compliance rates decreased for the other criteria that measured whether hand rubbing or hand washing was performed prior to contacting the infant and after wrapping the infant, and whether hand washing was performed correctly. The improvement in compliance with hand washing--the main focus of the new workflow--after changing diapers was especially significant. The results indicated that having a workflow on the occasions and process for hand hygiene during diaper changing was useful in standardising practice. Pre- and post-implementation audits were effective methods for evaluating the effect of translating evidence into practice. However, this project had limited success in improving compliance with hand hygiene. This suggested that more effort is needed to reinforce the importance of hand hygiene and compliance to the proposed workflow. In addition, this project showed that for change to take place successfully, environmental modifications, increased awareness and adequate communication to every staff member are essential. © 2012 The Authors. International Journal of Evidence

  8. Automatic fluid dispenser

    NASA Technical Reports Server (NTRS)

    Sakellaris, P. C. (Inventor)

    1977-01-01

    Fluid automatically flows to individual dispensing units at predetermined times from a fluid supply and is available only for a predetermined interval of time after which an automatic control causes the fluid to drain from the individual dispensing units. Fluid deprivation continues until the beginning of a new cycle when the fluid is once again automatically made available at the individual dispensing units.

  9. Poorly processed reusable surface disinfection tissue dispensers may be a source of infection.

    PubMed

    Kampf, Günter; Degenhardt, Stina; Lackner, Sibylle; Jesse, Katrin; von Baum, Heike; Ostermeyer, Christiane

    2014-01-21

    Reusable surface disinfectant tissue dispensers are used in hospitals in many countries because they allow immediate access to pre-soaked tissues for targeted surface decontamination. On the other hand disinfectant solutions with some active ingredients may get contaminated and cause outbreaks. We determined the frequency of contaminated surface disinfectant solutions in reusable dispensers and the ability of isolates to multiply in different formulations. Reusable tissue dispensers with different surface disinfectants were randomly collected from healthcare facilities. Solutions were investigated for bacterial contamination. The efficacy of two surface disinfectants was determined in suspension tests against two isolated species directly from a contaminated solution or after 5 passages without selection pressure in triplicate. Freshly prepared use solutions were contaminated to determine survival of isolates. 66 dispensers containing disinfectant solutions with surface-active ingredients were collected in 15 healthcare facilities. 28 dispensers from nine healthcare facilities were contaminated with approximately 107 cells per mL of Achromobacter species 3 (9 hospitals), Achromobacter xylosoxidans or Serratia marcescens (1 hospital each). In none of the hospitals dispenser processing had been adequately performed. Isolates regained susceptibility to the disinfectants after five passages without selection pressure but were still able to multiply in different formulations from different manufacturers at room temperature within 7 days. Neglecting adequate processing of surface disinfectant dispensers has contributed to frequent and heavy contamination of use-solutions based on surface active ingredients. Tissue dispenser processing should be taken seriously in clinical practice.

  10. Poorly processed reusable surface disinfection tissue dispensers may be a source of infection

    PubMed Central

    2014-01-01

    Background Reusable surface disinfectant tissue dispensers are used in hospitals in many countries because they allow immediate access to pre-soaked tissues for targeted surface decontamination. On the other hand disinfectant solutions with some active ingredients may get contaminated and cause outbreaks. We determined the frequency of contaminated surface disinfectant solutions in reusable dispensers and the ability of isolates to multiply in different formulations. Methods Reusable tissue dispensers with different surface disinfectants were randomly collected from healthcare facilities. Solutions were investigated for bacterial contamination. The efficacy of two surface disinfectants was determined in suspension tests against two isolated species directly from a contaminated solution or after 5 passages without selection pressure in triplicate. Freshly prepared use solutions were contaminated to determine survival of isolates. Results 66 dispensers containing disinfectant solutions with surface-active ingredients were collected in 15 healthcare facilities. 28 dispensers from nine healthcare facilities were contaminated with approximately 107 cells per mL of Achromobacter species 3 (9 hospitals), Achromobacter xylosoxidans or Serratia marcescens (1 hospital each). In none of the hospitals dispenser processing had been adequately performed. Isolates regained susceptibility to the disinfectants after five passages without selection pressure but were still able to multiply in different formulations from different manufacturers at room temperature within 7 days. Conclusions Neglecting adequate processing of surface disinfectant dispensers has contributed to frequent and heavy contamination of use-solutions based on surface active ingredients. Tissue dispenser processing should be taken seriously in clinical practice. PMID:24447780

  11. A simple low-cost of liquid I-131 dispenser for routine radiopharmaceutical dispensing at nuclear medicine department, Institut Kanser Negara

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Said, M. A.; Suhaimi, N. E. F.; Ashhar, Z. N., E-mail: aminhpj@gmail.com

    In routine radiopharmaceutical Iodine-131 ({sup 131}I) dispensing, the amount of radiation dose received by the personnel depends on the distance between the personnel and the source, the time spent manipulating the source and the amount of shielding used to reduce the dose rate from the source. The novel iRAD-I131 dispenser using recycle {sup 131}I liquid lead pot will lead into low cost production, less maintenance and low dose received by the personnel that prepared the {sup 131}I. The new fabricated of low cost {sup 131}I dispenser was tested and the dose received by personnel were evaluated. The body of leadmore » material is made from 2.5 cm lead shielded coated with epoxy paint to absorb the radiation dose up to 7.4 GBq of {sup 131} I. The lead pot was supported with two stainless steel rod. The Optically Stimulated Luminescence (OSL) nanodot was used in this study to measure the dose rate at both extremities for every personnel who prepared the {sup 131}I. Each OSL nanodot was attached at the fingertip. Three different personnel (experienced between one to ten years above in preparing the radiopharmaceuticals) were participated in this study. The average equivalent dose at right and left hand were 122.694 ± 121.637 µSv/GBq and 77.281 ± 62.146 µSv/GBq respectively. This study found that the dose exposure received using iRAD-I131 was less up to seven times compared to the conventional method. The comparison of experimental data using iRAD-I131 and established radiopharmaceutical dispenser was also discussed. The innovation of {sup 131}I dispenser is highly recommended in a small radiopharmaceutical facility with limited budget. The novel iRAD-I131 enables implementation of higher output liquid dispensing with low radiation dose to the personnel.« less

  12. Effects of geometric variables on rub characteristics of Ti-6Al-4V

    NASA Technical Reports Server (NTRS)

    Bill, R. C.; Wolak, J.; Wisander, D. W.

    1981-01-01

    Experiments simulating rub interactions between Ti-6Al-4V blade tips and various seal materials were conducted. The number of blade tips and the blade tip geometry were varied to determine their effects on rub forces and on wear phenomena. Contact was found to be quite unsteady for all blade tip geometries except for those incorporating deliberately rounded blade tips. The unsteady contact was characterized by long periods of rubbing contact and increasing blade tip that terminated in sudden rapid metal removal, sometimes accompanied by tearing and disruption of porous seal material under the rub surface. A model describing the blade tip loading is proposed and is based on the propagation of an elastic stress wave through the seal material as the seal material is dynamically compressed by the blade tip leading edge.

  13. Rotor-to-stator Partial Rubbing and Its Effects on Rotor Dynamic Response

    NASA Technical Reports Server (NTRS)

    Muszynska, Agnes; Franklin, Wesley D.; Hayashida, Robert D.

    1991-01-01

    Results from experimental and analytical studies on rotor to stationary element partial rubbings at several locations and their effects on rotor dynamic responses are presented. The mathematical model of a rubbing rotor is given. The computer program provides numerical results which agree with experimentally obtained rotor responses.

  14. Cable-Dispensing Cart

    NASA Technical Reports Server (NTRS)

    Bredberg, Alan S.

    2003-01-01

    A versatile cable-dispensing cart can support as many as a few dozen reels of cable, wire, and/or rope. The cart can be adjusted to accommodate reels of various diameters and widths, and can be expanded, contracted, or otherwise reconfigured by use of easily installable and removable parts that can be carried onboard. Among these parts are dispensing rods and a cable guide that enables dispensing of cables without affecting the direction of pull. Individual reels can be mounted on or removed from the cart without affecting the other reels: this feature facilitates the replacement or reuse of partially depleted reels, thereby helping to reduce waste. Multiple cables, wires, or ropes can be dispensed simultaneously. For maneuverability, the cart is mounted on three wheels. Once it has been positioned, the cart is supported by rubber mounts for stability and for prevention of sliding or rolling during dispensing operations. The stability and safety of the cart are enhanced by a low-center-of-gravity design. The cart can readily be disassembled into smaller units for storage or shipping, then reassembled in the desired configuration at a job site.

  15. Increasing Hand Washing Compliance With a Simple Visual Cue

    PubMed Central

    Boyer, Brian T.; Menachemi, Nir; Huerta, Timothy R.

    2014-01-01

    We tested the efficacy of a simple, visual cue to increase hand washing with soap and water. Automated towel dispensers in 8 public bathrooms were set to present a towel either with or without activation by users. We set the 2 modes to operate alternately for 10 weeks. Wireless sensors were used to record entry into bathrooms. Towel and soap consumption rates were checked weekly. There were 97 351 hand-washing opportunities across all restrooms. Towel use was 22.6% higher (P = .05) and soap use was 13.3% higher (P = .003) when the dispenser presented the towel without user activation than when activation was required. Results showed that a visual cue can increase hand-washing compliance in public facilities. PMID:24228670

  16. An experimental investigation of rubbing interaction in labyrinth seals at cryogenic temperature

    NASA Technical Reports Server (NTRS)

    Dolan, F. X.; Kennedy, F. E.; Schulson, E. M.

    1985-01-01

    An experimental program was carried out to address issues related to the observed cracking of the titanium knife edges on the labyrinth seals of the high pressure fuel pump (HPFP) in the Space Shuttle main engine (SSME). Thermal shock experiments were carried out using a jet specimen with geometry similar to the knife edge geometry. These tests demonstrate that cracking of the titanium alloy is possible in a situation involving repeated thermal cycles over a wide temperature range, as might be realized during a rub in the liquid hydrogen fuel pump. High speed rub interaction tests were conducted using a representative knife edge and seal geometry over a broad range of interaction rates. Alternative materials were also experimentally evaluated. These tests provide information which can be used to design improved labyrinth seals for the HPFP of the SSME. In particular, plasma-sprayed aluminum-graphite was found to be significantly better than aluminum alloy seals used at present from the standpoint of rub performance. Ion nitriding of the titanium alloy knife edges was also found to improve rub performance compared with the untreated baseline knife edge material.

  17. Rubbing time and bonding performance of one-step adhesives to primary enamel and dentin.

    PubMed

    Botelho, Maria Paula Jacobucci; Isolan, Cristina Pereira; Schwantz, Júlia Kaster; Lopes, Murilo Baena; Moraes, Rafael Ratto de

    2017-01-01

    This study investigated whether increasing the concentration of acidic monomers in one-step adhesives would allow reducing their application time without interfering with the bonding ability to primary enamel and dentin. Experimental one-step self-etch adhesives were formulated with 5 wt% (AD5), 20 wt% (AD20), or 35 wt% (AD35) acidic monomer. The adhesives were applied using rubbing motion for 5, 10, or 20 s. Bond strengths to primary enamel and dentin were tested under shear stress. A commercial etch-and-rinse adhesive (Single Bond 2; 3M ESPE) served as reference. Scanning electron microscopy was used to observe the morphology of bonded interfaces. Data were analysed at p<0.05. In enamel, AD35 had higher bond strength when rubbed for at least 10 s, while application for 5 s generated lower bond strength. In dentin, increased acidic monomer improved bonding only for 20 s rubbing time. The etch-and-rinse adhesive yielded higher bond strength to enamel and similar bonding to dentin as compared with the self-etch adhesives. The adhesive layer was thicker and more irregular for the etch-and-rinse material, with no appreciable differences among the self-etch systems. Overall, increasing the acidic monomer concentration only led to an increase in bond strength to enamel when the rubbing time was at least 10 s. In dentin, despite the increase in bond strength with longer rubbing times, the results favoured the experimental adhesives compared to the conventional adhesive. Reduced rubbing time of self-etch adhesives should be avoided in the clinical setup.

  18. Implantable Drug Dispenser

    NASA Technical Reports Server (NTRS)

    Collins, E. R. J.

    1983-01-01

    Drugs such as insulin are injected as needed directly into bloodstream by compact implantable dispensing unit. Two vapor cavities produce opposing forces on drug-chamber diaphragm. Heaters in cavities allow control of direction and rate of motion of bellows. Dispensing capsule fitted with coil so batteries can be recharged by induction.

  19. Visitor characteristics and alcohol-based hand sanitizer dispenser locations at the hospital entrance: Effect on visitor use rates.

    PubMed

    Hobbs, Mary A; Robinson, Susan; Neyens, David M; Steed, Connie

    2016-03-01

    Hospital visitors' hand hygiene (HH) is an important aspect of preventing health care-associated infections, but little is known about visitors' use of alcohol-based hand sanitizers (AHS). The study aim was to examine if use of AHS is influenced by visitor characteristics and the location of AHS within the lobby of a large hospital. An observational study was conducted with AHS placed in 3 different locations. The data included visitor characteristics and if AHS were used. The results suggest that visitors are 5.28 times (95% confidence interval [CI], 3.68-7.82) more likely to use AHS when dispensers are located in the middle of the lobby with limited landmarks or barriers, 1.35 times more likely to use the AHS in the afternoon compared with the morning, or when they are younger visitors (adjusted odds ratio, 1.47; 95% CI, 1.09-1.97). Individuals in a group are more likely (adjusted odds ratio, 1.39; 95% CI, 1.06-1.84) to use AHS. In addition to location, time of day, and age, there is a group effect that results in visitors being more likely to use AHS when in a group. The increased use related to groups may serve as a mechanism to encourage visitor HH. The results suggest future research opportunities to investigate the effect of group dynamics and social pressure on visitor AHS use and to identify strategies for improving visitor HH. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  20. Office dispensing: a responsible approach.

    PubMed

    Farris, P K

    2000-09-01

    Office dispensing is a value added service in the dermatologist's office. As dermatologists we can recommend products with known scientific validity that will enhance patient care and provide reliable therapeutic results. Patients enjoy the convenience of being able to purchase products in the office and appreciate the dermatologist who spends time outlining a daily skin care regimen. Office dispensing benefits the physician by forcing him or her to keep current on new innovations in skin care and serves as an effective way to develop your cosmetic practice. Antiaging products, moisturizers and sunscreens, cleansers, and acne products are the basics for any in-office dispensing operation. The addition of hair and nail care products constitutes more advanced dispensing. Despite the mutual benefits for both the patient and physician, office dispensing continues to be controversial. The American Medical Association is concerned that selling health-related goods in the office may compromise the patient-physician relationship. The American Academy of Dermatology continues to support the right of dermatologists to dispense products in their office as long as it is in the best interest of the patient, as it is with all other dermatologic care. Dermatologists must preserve the right to dispense by conducting themselves in a highly professional and ethical manner.

  1. Antibacterial Efficacy of Several Surgical Hand Preparation Products Used by Veterinary Students.

    PubMed

    Chou, Po-Yen; Doyle, Aimie J; Arai, Shiori; Burke, Pierre J; Bailey, Trina R

    2016-05-01

    To compare the antibacterial efficacy of different surgical hand antisepsis protocols used by veterinary students. Prospective, randomized, controlled study. Third year veterinary students (n=45). The participants were randomly assigned to 4 of the following 12 hand preparation product/time combinations: nonabrasive hand scrub method with 4% chlorhexidine gluconate (CH); hand rub with a mixture of 30% 1-propanol and 45% 2-propanol solution (MPS), 70% 2-propanol solution (IPS), or 61% ethanol solution with 1% chlorhexidine gluconate (ES/CH), with a contact time of 1.5, 3, or 5 minutes. Antibacterial efficacy was assessed after surgical hand preparation and at the end of surgery. Log reductions of total bacterial colony forming unit (CFU)/mL and positive aerobic culture rates were compared using multivariable analysis of variance and multivariable logistic regression, respectively. After surgical hand preparation, CH and ES/CH provided significantly higher log CFU reduction and lower positive culture rate for Gram-positive and spore-forming bacteria compared to MPS and IPS. Increase in contact time did not provide significant improvement in bacterial reduction. At the end of surgery, ES/CH provided significantly higher log CFU reduction compared to IPS and lower positive culture rate for Gram-positive bacteria compared to CH, MPS, and IPS. Increase in contact time significantly improved log CFU reduction in ES/CH and MPS groups. In our population of veterinary students ES/CH hand rubs or CH scrubs were more effective in reducing bacterial CFU during surgical hand preparation than MPS or IPS. © Copyright 2016 by The American College of Veterinary Surgeons.

  2. Rubbing time and bonding performance of one-step adhesives to primary enamel and dentin

    PubMed Central

    Botelho, Maria Paula Jacobucci; Isolan, Cristina Pereira; Schwantz, Júlia Kaster; Lopes, Murilo Baena; de Moraes, Rafael Ratto

    2017-01-01

    Abstract Objectives: This study investigated whether increasing the concentration of acidic monomers in one-step adhesives would allow reducing their application time without interfering with the bonding ability to primary enamel and dentin. Material and methods: Experimental one-step self-etch adhesives were formulated with 5 wt% (AD5), 20 wt% (AD20), or 35 wt% (AD35) acidic monomer. The adhesives were applied using rubbing motion for 5, 10, or 20 s. Bond strengths to primary enamel and dentin were tested under shear stress. A commercial etch-and-rinse adhesive (Single Bond 2; 3M ESPE) served as reference. Scanning electron microscopy was used to observe the morphology of bonded interfaces. Data were analysed at p<0.05. Results: In enamel, AD35 had higher bond strength when rubbed for at least 10 s, while application for 5 s generated lower bond strength. In dentin, increased acidic monomer improved bonding only for 20 s rubbing time. The etch-and-rinse adhesive yielded higher bond strength to enamel and similar bonding to dentin as compared with the self-etch adhesives. The adhesive layer was thicker and more irregular for the etch-and-rinse material, with no appreciable differences among the self-etch systems. Conclusion: Overall, increasing the acidic monomer concentration only led to an increase in bond strength to enamel when the rubbing time was at least 10 s. In dentin, despite the increase in bond strength with longer rubbing times, the results favoured the experimental adhesives compared to the conventional adhesive. Reduced rubbing time of self-etch adhesives should be avoided in the clinical setup. PMID:29069150

  3. Resin-Powder Dispenser

    NASA Technical Reports Server (NTRS)

    Standfield, Clarence E.

    1994-01-01

    Resin-powder dispenser used at NASA's Langley Research Center for processing of composite-material prepregs. Dispenser evenly distributes powder (resin polymer and other matrix materials in powder form) onto wet uncured prepregs. Provides versatility in distribution of solid resin in prepreg operation. Used wherever there is requirement for even, continuous distribution of small amount of powder.

  4. Application of basic pharmacology and dispensing practice of antibiotics in accredited drug-dispensing outlets in Tanzania.

    PubMed

    Minzi, Om; Manyilizu, Vs

    2013-01-01

    Provision of pharmaceutical services in accredited drug-dispensing outlets (ADDOs) in Tanzania has not been reported. This study compared the antibiotics dispensing practice between ADDOs and part II shops, or duka la dawa baridi (DLDBs), in Tanzania. This was a cross-sectional study that was conducted in ADDOs and DLDBs. A simulated client method for data collection was used, and a total of 85 ADDOs, located in Mvomero, Kilombero, and Morogoro rural districts, were compared with 60 DLDBs located in Kibaha district. The research assistants posed as simulated clients and requested to buy antibiotics from ADDOs and DLDBs after presenting a case scenario or disease condition. Among the diseases presented were those requiring antibiotics and those usually managed only by oral rehydration salt or analgesics. The simulated clients wanted to know the antibiotics that were available at the shop. The posed questions set a convincing ground to the dispenser either to dispense the antibiotic directly, request a prescription, or refer the patient to a health facility. Proportions were used to summarize categorical variables between ADDOs and DLDBs, and the chi-square test was used to test for statistical difference between the two drug-outlet types in terms of antibiotic-dispensing practice. As many as 40% of trained ADDO dispensers no longer worked at the ADDO shops, so some of the shops employed untrained staff. A larger proportion of ADDOs than DLDBs dispensed antibiotics without prescriptions (P = 0.004). The overall results indicate that there was no difference between the two types of shops in terms of adhering to regulations for dispensing antibiotics. However, in some circumstances, eg, antibiotic sale without prescription and no referral made, for complicated cases, ADDOs performed worse than DLDBs. As many as 30% of DLDBs and 35% of ADDOs dispensed incomplete doses of antibiotics. In both ADDOs and DLDBs, fortified procaine penicillin powder was dispensed as topical

  5. Safe pill-dispensing.

    PubMed

    Testa, Massimiliano; Pollard, John

    2007-01-01

    Each patient is supplied with a smart-card containing a Radio Frequency IDentification (RFID) chip storing a unique identification code. The patient places the Smart-card on a pill-dispenser unit containing an RFID reader. The RFID chip is read and the code sent to a Base-station via a wireless Bluetooth link. A database containing both patient details and treatment information is queried at the Base-station using the RFID as the search key. The patient's treatment data (i.e., drug names, quantities, time, etc.) are retrieved and sent back to the pill-dispenser unit via Bluetooth. Appropriate quantities of the required medications are automatically dispensed, unless the patient has already taken his/her daily dose. Safe, confidential communication and operation is ensured.

  6. Apparatus for dispensing material

    DOEpatents

    Sutter, Peter Werner [Beach, NY; Sutter, Eli Anguelova [Beach, NY

    2011-07-05

    An apparatus capable of dispensing drops of material with volumes on the order of zeptoliters is described. In some embodiments of the inventive pipette the size of the droplets so dispensed is determined by the size of a hole, or channel, through a carbon shell encapsulating a reservoir that contains material to be dispensed. The channel may be formed by irradiation with an electron beam or other high-energy beam capable of focusing to a spot size less than about 5 nanometers. In some embodiments, the dispensed droplet remains attached to the pipette by a small thread of material, an atomic scale meniscus, forming a virtually free-standing droplet. In some embodiments the droplet may wet the pipette tip and take on attributes of supported drops. Methods for fabricating and using the pipette are also described.

  7. Electronic and elastic properties of new semiconducting oP(12)-type RuB(2) and OsB(2).

    PubMed

    Hao, Xianfeng; Xu, Yuanhui; Gao, Faming

    2011-03-30

    Using first-principles total energy calculations we investigate the structural, elastic and electronic properties of new hypothetical oP(12)-type phase RuB(2) and OsB(2). The calculations indicate that the oP(12)-type phase RuB(2) and OsB(2) are thermodynamically and mechanically stable. Remarkably, the new phases RuB(2) and OsB(2) are predicted to be semiconductors, and the appearance of band gaps is ascribed to the enhanced B-B covalent hybridization. Compared to metallic oP(6)-type RuB(2) and OsB(2) phases, the new phases possess similar mechanical properties and hardness. The combination of the probability of tunable electronic properties, strong stiffness and high hardness make RuB(2) and OsB(2) attractive and interesting for advanced applications. © 2011 IOP Publishing Ltd

  8. [The effectiveness of hand hygiene products on MRSA colonization of health care workers by using CHROMagar MRSA].

    PubMed

    Koçak Tufan, Zeliha; Irmak, Hasan; Bulut, Cemal; Cesur, Salih; Kınıklı, Sami; Demiröz, Ali Pekcan

    2012-04-01

    The aims of this study were; to investigate the hand hygiene compliance of the health care workers (HCWs) during their routine patient care, to determine the methicillin-resistant Staphylococcus aureus (MRSA) hand colonization of the HCWs, to investigate the effect of different hand hygiene products on MRSA colonization and to evaluate the effectiveness of chromogenic agar for detecting MRSA. HCWs were investigated during their routine patient care and hand cultures were taken before and after hand wash/hygiene. Two different techniques were used to obtain the hand cultures: fingertip method (CHROMagar MRSA containing HygiSlide); and direct swab method and then inoculation to CHROMagar MRSA media. MRSA strains grown on those cultures were confirmed with conventional methods. A total of 100 HCWs (of them 61 were female; mean age: 32.7 ± 5.2 years; age range: 25-51 years) involving physicians (n= 33), nurses (n= 38) and health care assistants (n= 29), were included in the study. MRSA was detected in 39% and 11% before hand hygiene and in 13% and 6% after hand hygiene, with HygiSlide CHROMagar media and with CHROMagar in plate media, respectively. No difference were found regarding clinics, occupations, or the type of patient handling in those HCWs who were positive (n= 13) for MRSA colonization following hand hygiene, and those who were negative (n= 26). However, the type of the hand hygiene product used exhibited a statistical difference. None of the seven HCWs who used alcohol based hand rub revealed growth in the second culture while 10 of 19 (53%) HCWs who used soap and three of 13 (23%) HCWs who used chlorhexidine were still colonized with MRSA. In terms of reduction in the MRSA counts, the most effective one was the alcohol based hand rub while the soap was the least, since seven of 19 (37%) HCWs who used soap showed no reduction at all in the MRSA counts. A high ratio of hand colonization with MRSA was detected in our hospital staff (39%). It was shown that

  9. Micromachined chemical jet dispenser

    DOEpatents

    Swierkowski, Steve P.

    1999-03-02

    A dispenser for chemical fluid samples that need to be precisely ejected in size, location, and time. The dispenser is a micro-electro-mechanical systems (MEMS) device fabricated in a bonded silicon wafer and a substrate, such as glass or silicon, using integrated circuit-like fabrication technology which is amenable to mass production. The dispensing is actuated by ultrasonic transducers that efficiently produce a pressure wave in capillaries that contain the chemicals. The 10-200 .mu.m diameter capillaries can be arranged to focus in one spot or may be arranged in a larger dense linear array (.about.200 capillaries). The dispenser is analogous to some ink jet print heads for computer printers but the fluid is not heated, thus not damaging certain samples. Major applications are in biological sample handling and in analytical chemical procedures such as environmental sample analysis, medical lab analysis, or molecular biology chemistry experiments.

  10. Analysis on accuracy improvement of rotor-stator rubbing localization based on acoustic emission beamforming method.

    PubMed

    He, Tian; Xiao, Denghong; Pan, Qiang; Liu, Xiandong; Shan, Yingchun

    2014-01-01

    This paper attempts to introduce an improved acoustic emission (AE) beamforming method to localize rotor-stator rubbing fault in rotating machinery. To investigate the propagation characteristics of acoustic emission signals in casing shell plate of rotating machinery, the plate wave theory is used in a thin plate. A simulation is conducted and its result shows the localization accuracy of beamforming depends on multi-mode, dispersion, velocity and array dimension. In order to reduce the effect of propagation characteristics on the source localization, an AE signal pre-process method is introduced by combining plate wave theory and wavelet packet transform. And the revised localization velocity to reduce effect of array size is presented. The accuracy of rubbing localization based on beamforming and the improved method of present paper are compared by the rubbing test carried on a test table of rotating machinery. The results indicate that the improved method can localize rub fault effectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Outbreaks where food workers have been implicated in the spread of foodborne disease. Part 9. Washing and drying of hands to reduce microbial contamination.

    PubMed

    Todd, Ewen C D; Michaels, Barry S; Smith, Debra; Greig, Judy D; Bartleson, Charles A

    2010-10-01

    During various daily activities at home and work, hands quickly become contaminated. Some activities increase the risk of finger contamination by pathogens more than others, such as the use of toilet paper to clean up following a diarrheal episode, changing the diaper of a sick infant, blowing a nose, or touching raw food materials. Many foodborne outbreak investigation reports have identified the hands of food workers as the source of pathogens in the implicated food. The most convenient and efficient way of removing pathogens from hands is through hand washing. Important components of hand washing are potable water for rinsing and soaps to loosen microbes from the skin. Hand washing should occur after any activity that soils hands and certainly before preparing, serving, or eating food. Antimicrobial soaps are marginally more effective than plain soaps, but constant use results in a buildup of the antimicrobial compound on the skin. The time taken to wash hands and the degree of friction generated during lathering are more important than water temperature for removing soil and microorganisms. However, excessive washing and scrubbing can cause skin damage and infections. Drying hands with a towel removes pathogens first by friction during rubbing with the drying material and then by wicking away the moisture into that material. Paper rather than cloth towels should be encouraged, although single-use cloth towels are present in the washrooms of higher class hotels and restaurants. Warm air dryers remove moisture and any surface microorganisms loosened by washing from hands by evaporation while the hands are rubbed together vigorously; however, these dryers take too long for efficient use. The newer dryers with high-speed air blades can achieve dryness in 10 to 15 s without hand rubbing.

  12. Two time-series analyses of the impact of antibiotic consumption and alcohol-based hand disinfection on the incidences of nosocomial methicillin-resistant Staphylococcus aureus infection and Clostridium difficile infection.

    PubMed

    Kaier, Klaus; Hagist, Christian; Frank, Uwe; Conrad, Andreas; Meyer, Elisabeth

    2009-04-01

    To determine the impact of antibiotic consumption and alcohol-based hand disinfection on the incidences of nosocomial methicillin-resistant Staphylococcus aureus (MRSA) infection and Clostridium difficile infection (CDI). Two multivariate time-series analyses were performed that used as dependent variables the monthly incidences of nosocomial MRSA infection and CDI at the Freiburg University Medical Center during the period January 2003 through October 2007. The volume of alcohol-based hand rub solution used per month was quantified in liters per 1,000 patient-days. Antibiotic consumption was calculated in terms of the number of defined daily doses per 1,000 patient-days per month. The use of alcohol-based hand rub was found to have a significant impact on the incidence of nosocomial MRSA infection (P< .001). The multivariate analysis (R2=0.66) showed that a higher volume of use of alcohol-based hand rub was associated with a lower incidence of nosocomial MRSA infection. Conversely, a higher level of consumption of selected antimicrobial agents was associated with a higher incidence of nosocomial MRSA infection. This analysis showed this relationship was the same for the use of second-generation cephalosporins (P= .023), third-generation cephalosporins (P= .05), fluoroquinolones (P= .01), and lincosamides (P= .05). The multivariate analysis (R2=0.55) showed that a higher level of consumption of third-generation cephalosporins (P= .008), fluoroquinolones (P= .084), and/or macrolides (P= .007) was associated with a higher incidence of CDI. A correlation with use of alcohol-based hand rub was not detected. In 2 multivariate time-series analyses, we were able to show the impact of hand hygiene and antibiotic use on the incidence of nosocomial MRSA infection, but we found no association between hand hygiene and incidence of CDI.

  13. Bilateral Glaucomatous Optic Neuropathy Caused by Eye Rubbing.

    PubMed

    Savastano, Alfonso; Savastano, Maria Cristina; Carlomusto, Laura; Savastano, Silvio

    2015-01-01

    In this report, we describe a particular condition of a 52-year-old man who showed advanced bilateral glaucomatous-like optic disc damage, even though the intraocular pressure resulted normal during all examinations performed. Visual field test, steady-state pattern electroretinogram, retinal nerve fiber layer and retinal tomographic evaluations were performed to evaluate the optic disc damage. Over a 4-year observational period, his visual acuity decreased to 12/20 in the right eye and counting fingers in the left eye. Visual fields were severely compromised, and intraocular pressure values were not superior to 14 mm Hg during routine examinations. An accurate anamnesis and the suspicion of this disease represent a crucial aspect to establish the correct diagnosis. In fact, our patient strongly rubbed his eyes for more than 10 h per day. Recurrent and continuous eye rubbing can induce progressive optic neuropathy, causing severe visual field damage similar to the pathology of advanced glaucoma.

  14. Rotor-to-stator rub vibration in centrifugal compressor

    NASA Technical Reports Server (NTRS)

    Gao, J. J.; Qi, Q. M.

    1985-01-01

    One example of excessive vibration encountered during loading of a centrifugal compressor train (H type compressor with HP casing) is discussed. An investigation was made of the effects of the dynamic load on the bearing stiffness and the rotor-bearing system critical speed. The high vibration occurred at a "threshold load," but the machine didn't run smoothly due to rubs even when it had passed through the threshold load. The acquisition and discussion of the data taken in the field as well as a description of the case history which utilizes background information to identify the malfunction conditions is presented. The analysis shows that the failures, including full reverse precession rub and exact one half subharmonic vibration, were caused by the oversize bearings and displacement of the rotor center due to foundation deformation and misalignment between gear shafts, etc. The corrective actions taken to alleviate excessive vibration and the problems which remain to be solved are also presented.

  15. Application of basic pharmacology and dispensing practice of antibiotics in accredited drug-dispensing outlets in Tanzania

    PubMed Central

    Minzi, OM; Manyilizu, VS

    2013-01-01

    Background Provision of pharmaceutical services in accredited drug-dispensing outlets (ADDOs) in Tanzania has not been reported. This study compared the antibiotics dispensing practice between ADDOs and part II shops, or duka la dawa baridi (DLDBs), in Tanzania. Methodology This was a cross-sectional study that was conducted in ADDOs and DLDBs. A simulated client method for data collection was used, and a total of 85 ADDOs, located in Mvomero, Kilombero, and Morogoro rural districts, were compared with 60 DLDBs located in Kibaha district. The research assistants posed as simulated clients and requested to buy antibiotics from ADDOs and DLDBs after presenting a case scenario or disease condition. Among the diseases presented were those requiring antibiotics and those usually managed only by oral rehydration salt or analgesics. The simulated clients wanted to know the antibiotics that were available at the shop. The posed questions set a convincing ground to the dispenser either to dispense the antibiotic directly, request a prescription, or refer the patient to a health facility. Proportions were used to summarize categorical variables between ADDOs and DLDBs, and the chi-square test was used to test for statistical difference between the two drug-outlet types in terms of antibiotic-dispensing practice. Results As many as 40% of trained ADDO dispensers no longer worked at the ADDO shops, so some of the shops employed untrained staff. A larger proportion of ADDOs than DLDBs dispensed antibiotics without prescriptions (P = 0.004). The overall results indicate that there was no difference between the two types of shops in terms of adhering to regulations for dispensing antibiotics. However, in some circumstances, eg, antibiotic sale without prescription and no referral made, for complicated cases, ADDOs performed worse than DLDBs. As many as 30% of DLDBs and 35% of ADDOs dispensed incomplete doses of antibiotics. In both ADDOs and DLDBs, fortified procaine penicillin

  16. Micromachined chemical jet dispenser

    DOEpatents

    Swierkowski, S.P.

    1999-03-02

    A dispenser is disclosed for chemical fluid samples that need to be precisely ejected in size, location, and time. The dispenser is a micro-electro-mechanical systems (MEMS) device fabricated in a bonded silicon wafer and a substrate, such as glass or silicon, using integrated circuit-like fabrication technology which is amenable to mass production. The dispensing is actuated by ultrasonic transducers that efficiently produce a pressure wave in capillaries that contain the chemicals. The 10-200 {micro}m diameter capillaries can be arranged to focus in one spot or may be arranged in a larger dense linear array (ca. 200 capillaries). The dispenser is analogous to some ink jet print heads for computer printers but the fluid is not heated, thus not damaging certain samples. Major applications are in biological sample handling and in analytical chemical procedures such as environmental sample analysis, medical lab analysis, or molecular biology chemistry experiments. 4 figs.

  17. Opportunity's 'Rub al Khali' Panorama

    NASA Technical Reports Server (NTRS)

    2005-01-01

    [figure removed for brevity, see original site] Click on the image for Opportunity's 'Rub al Khali' Panorama (QTVR)

    This panoramic image, dubbed 'Rub al Khali,' was acquired by NASA's Mars Exploration Rover Opportunity on the plains of Meridiani during the period from the rover's 456th to 464th sols on Mars (May 6 to May 14, 2005). Opportunity was about 2 kilometers (1.2 miles) south of 'Endurance Crater' at a place known informally as 'Purgatory Dune.'

    The rover was stuck in the dune's deep fine sand for more than a month. 'Rub al Khali' (Arabic translation: 'the empty quarter') was chosen as the name for this panorama because it is the name of a similarly barren, desolate part of the Saudi Arabian desert on Earth.

    The view spans 360 degrees. It consists of images obtained in 97 individual pointings of the panoramic camera. The camera took images with five camera filters at each pointing. This 22,780-by-6,000-pixel mosaic is an approximately true-color rendering generated using the images acquired through filters admitting light wavelengths of 750, 530, and 480 nanometers.

    Lighting varied during the nine sols it took to acquire this panorama, resulting in some small image seams within the mosaic. These seams have been smoothed in sky parts of the mosaic to better simulate the vista that a person would see if able to view it all at the same time on Mars.

    Opportunity's tracks leading back to the north (center of the panorama) are a reminder of the rover's long trek from Endurance Crater. The deep ruts dug by Opportunity's wheels as it became stuck in the sand appear in the foreground. The crest and trough of the last ripple the rover crossed before getting stuck is visible in the center. These wind-formed sand features are only about 10 to 15 centimeters (4 to 6 inches) tall. The crest of the actual ripple where the rover got stuck can be seen just to the right of center. The tracks and a few other places on and near ripple crests can

  18. 21 CFR 888.4200 - Cement dispenser.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cement dispenser. 888.4200 Section 888.4200 Food... DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4200 Cement dispenser. (a) Identification. A cement dispenser is a nonpowered syringe-like device intended for use in placing bone cement (§ 888.3027) into...

  19. 21 CFR 888.4200 - Cement dispenser.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cement dispenser. 888.4200 Section 888.4200 Food... DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4200 Cement dispenser. (a) Identification. A cement dispenser is a nonpowered syringe-like device intended for use in placing bone cement (§ 888.3027) into...

  20. 21 CFR 888.4200 - Cement dispenser.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cement dispenser. 888.4200 Section 888.4200 Food... DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4200 Cement dispenser. (a) Identification. A cement dispenser is a nonpowered syringe-like device intended for use in placing bone cement (§ 888.3027) into...

  1. 21 CFR 888.4200 - Cement dispenser.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cement dispenser. 888.4200 Section 888.4200 Food... DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4200 Cement dispenser. (a) Identification. A cement dispenser is a nonpowered syringe-like device intended for use in placing bone cement (§ 888.3027) into...

  2. 21 CFR 888.4200 - Cement dispenser.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cement dispenser. 888.4200 Section 888.4200 Food... DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4200 Cement dispenser. (a) Identification. A cement dispenser is a nonpowered syringe-like device intended for use in placing bone cement (§ 888.3027) into...

  3. Quantifying the Hawthorne Effect in Hand Hygiene Compliance Through Comparing Direct Observation With Automated Hand Hygiene Monitoring.

    PubMed

    Hagel, Stefan; Reischke, Jana; Kesselmeier, Miriam; Winning, Johannes; Gastmeier, Petra; Brunkhorst, Frank M; Scherag, André; Pletz, Mathias W

    2015-08-01

    To quantify the Hawthorne effect of hand hygiene performance among healthcare workers using direct observation. Prospective observational study. Intensive care unit, university hospital. Direct observation of hand hygiene compliance over 48 audits of 2 hours each. Simultaneously, hand hygiene events (HHEs) were recorded using electronic alcohol-based handrub dispensers. Directly observed and electronically recorded HHEs during the 2 hours of direct observation were compared using Spearman correlations and Bland-Altman plots. To quantify the Hawthorne effect, we compared the number of electronically recorded HHEs during the direct observation periods with the re-scaled electronically recorded HHEs in the 6 remaining hours of the 8-hour working shift. A total of 3,978 opportunities for hand hygiene were observed during the 96 hours of direct observation. Hand hygiene compliance was 51% (95% CI, 49%-53%). There was a strong positive correlation between directly observed compliance and electronically recorded HHEs (ρ=0.68 [95% CI, 0.49-0.81], P<.0001). In the 384 hours under surveillance, 4,180 HHEs were recorded by the electronic dispensers. Of those, 2,029 HHEs were recorded during the 96 hours in which direct observation was also performed, and 2,151 HHEs were performed in the remaining 288 hours of the same working shift that were not under direct observation. Healthcare workers performed 8 HHEs per hour when not under observation compared with 21 HHEs per hour during observation. Directly and electronically observed HHEs were in agreement. We observed a marked influence of the Hawthorne effect on hand hygiene performance.

  4. An Australian Response to Michael Bérubé

    ERIC Educational Resources Information Center

    Frances, Raelene

    2016-01-01

    This article supports Bérubé's conclusion regarding the intellectual health of humanities scholarship. However, it argues that the case of "contingent faculty"--or academics with short-term or casual contracts--is in many respects different in Australia to the situation he outlines for the US. Whilst a variety of funding pressures have…

  5. System for Dispensing a Precise Amount of Fluid

    DOEpatents

    Benett, William J.; Krulevitch, Peter A.; Visuri, Steven R.; Dzenitis, John M.; Ness, Kevin D.

    2008-08-12

    A dispensing system delivers a precise amount of fluid for biological or chemical processing and/or analysis. Dispensing means moves the fluid. The dispensing means is operated by a pneumatic force. Connection means delivers the fluid to the desired location. An actuator means provides the pneumatic force to the dispensing means. Valving means transmits the pneumatic force from the actuator means to the dispensing means.

  6. Isolation of Raoultella planticola from refillable antimicrobial liquid soap dispensers in a dental setting

    PubMed Central

    Tomlin, Nancy; Ruby, John D.

    2014-01-01

    Background Liquid antimicrobial soaps are commonly used in the dental healthcare setting for hand washing to minimize the potential spread of infectious agents to healthcare workers (HCW) and patients. The purpose of the current study was to evaluate possible bacterial contamination of antimicrobial liquid soap dispensers located in two institutional comprehensive dental care clinics. Methods Fourteen soap dispensers and original stock containers were sampled. A 1 ml aliquot was diluted in 10 ml of phosphate buffer (Tween 80). Serial dilutions were plated in duplicate on neutralizing agar and incubated for 7 days. Molecular identification was performed using 500 bp comparisons of 16S rDNA sequencing. Taq PCR was performed with sequence specific primers for Raoultella species. Results Bacterial growth was observed at 18 hours for 57% (8/14) of soap dispenser samples. Bacterial densities ranged from 4 ×102–6 ×109 CFU/mL. Original commercial containers exhibited no growth. Isolates were identified as Raoultella (Klebsiella) planticola. Conclusions This is the first study indicating recovery of R. planticola from antimicrobial liquid soap dispensers. R. planticola is a recognized environmental opportunistic pathogen that potentially poses a health concern. Practical Implications These findings indicate compliance problems with infection prevention recommendations and support the CDC’s recommendation that dispensers should not be “topped off”. High bacterial loads of R. planticola are inconsistent with infection control practices and are a concern since transmission and possible infection to the HCW or the patient may occur. PMID:25819655

  7. Theoretical and experimental investigation on the sudden unbalance and rub-impact in rotor system caused by blade off

    NASA Astrophysics Data System (ADS)

    Wang, Cun; Zhang, Dayi; Ma, Yanhong; Liang, Zhichao; Hong, Jie

    2016-08-01

    Blade loss from a running turbofan rotor will introduce sudden unbalance into the dynamical system, and as a consequence leads to the rub-impact, the asymmetry of rotor and a series of interesting dynamic characteristics. The paper focuses on the theoretical study on the sudden unbalance and rub-impact caused by blade loss, in particular investigates the response of the rotor on a rotor test rig with sudden unbalance and rub-impact device designed respectively. The results reveal that the sudden unbalance will induce impact effect on the rotor, and critical speed frequency is excited in frequency spectrum. Meantime, the impact effect is more obvious for the rotor operating above critical speed. The influence of rub-impact is considered as additional constraint to the rotor, analyzed by the theory of time-varying system for the first time, and the results are evaluated by experimental tests. The study shows that great attention should be paid to the dynamical design for the overhung rotor system, additional constraint and corresponding analysis method in rub-impact need to be intensively studied.

  8. An evaluation of hospital hand hygiene practice and glove use in Hong Kong.

    PubMed

    Chau, Janita P-C; Thompson, David R; Twinn, Sheila; Lee, Diana T F; Pang, Sharon W M

    2011-05-01

    To identify omissions in hand hygiene practice and glove use among hospital workers in Hong Kong. Hospital-acquired infection is the commonest complication affecting hospitalised patients. Even though research evidence suggests that hand hygiene and proper glove use are the most important ways to prevent the spread of disease and infection, compliance with both are reported to be unacceptably low. An observational study of hospital workers in one acute and two convalescence and rehabilitation hospitals in Hong Kong was conducted. The participating clinical areas included the medical and surgical wards, accident and emergency department and intensive care unit. Hand hygiene practice and glove use amongst 206 hospital health and support workers, stratified according to years of working experience, were observed. The number of observed episodes for hand hygiene was 1037 and for glove use 304. Compliance with hand hygiene was 74.7% and with glove use 72.4%. In approximately two-third of episodes, participants washed their hands after each patient contact; though, 78.5% failed to rub their hands together vigorously for at least 15 seconds. The major break in compliance with glove use was failure to change gloves between procedures on the same patient. In 28.6% of observed glove use episodes, participants did not wear gloves during procedures that exposed them to blood, body fluids, excretion, non-intact skin or mucous membranes. Significant differences in performance scores on antiseptic hand rub were found between the two types of hospital and on glove use between the three groups of work experience: ≤ 5, 6-10, >10 years. Education and reinforcement of proper hand hygiene practice and glove use among hospital health and support workers is needed. © 2011 Blackwell Publishing Ltd.

  9. Effects of eye rubbing on the levels of protease, protease activity and cytokines in tears: relevance in keratoconus.

    PubMed

    Balasubramanian, Sivaraman A; Pye, David C; Willcox, Mark D P

    2013-03-01

    Proteases, protease activity and inflammatory molecules in tears have been found to be relevant in the pathogenesis of keratoconus. We sought to determine the influence of eye rubbing on protease expression, protease activity and concentration of inflammatory molecules in tears. Basal tears were collected from normal volunteers before and after 60 seconds of experimental eye rubbing. The total amount of matrix metalloproteinase (MMP)-13 and inflammatory molecules interleukin (IL)-6 and tumour necrosis factor (TNF)-α in the tear samples were measured using specific enzyme-linked immunosorbent assays (ELISA). Tear collagenase activity was investigated using a specific activity assay. The concentrations of MMP-13 (51.9 ± 34.3 versus 63 ± 36.8 pg/ml, p = 0.006), IL-6 (1.24 ± 0.98 versus 2.02 ± 1.52 pg/ml, p = 0.004) and TNF-α (1.16 ± 0.74 versus 1.44 ± 0.66 pg/ml, p = 0.003) were significantly increased in normal subjects after eye rubbing. The experimental eye rub did not alter significantly the collagenase activity (5.02 ± 3 versus 7.50 ± 3.90 fluorescent intensity units, p = 0.14) of tears. Eye rubbing for 60 seconds increased the level of tear MMP-13, IL-6 and TNF-α in normal study subjects. This increase in protease, protease activity and inflammatory mediators in tears after eye rubbing may be exacerbated even further during persistent and forceful eye rubbing seen in people with keratoconus and this in turn may contribute to the progression of the disease. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  10. Severe acute corneal hydrops in a patient with Down syndrome and persistent eye rubbing.

    PubMed

    Ozcan, Altan A; Ersoz, T Reha

    2007-01-01

    We report a case of severe acute corneal hydrops in an 11-year-old boy with keratoconus associated with Down syndrome and vigorous eye rubbing. Complete resolution of the corneal edema and a central corneal scar was seen in the 8th week of final follow-up. Eye-rubbing may play a role in the pathogenesis of acute hydrops, and conventional therapy can be successful in its management, even in severe cases.

  11. Plug-in nanoliter pneumatic liquid dispenser with nozzle design flexibility.

    PubMed

    Choi, In Ho; Kim, Hojin; Lee, Sanghyun; Baek, Seungbum; Kim, Joonwon

    2015-11-01

    This paper presents a novel plug-in nanoliter liquid dispensing system with a plug-and-play interface for simple and reversible, yet robust integration of the dispenser. A plug-in type dispenser was developed to facilitate assembly and disassembly with an actuating part through efficient modularization. The entire process for assembly and operation of the plug-in dispenser is performed via the plug-and-play interface in less than a minute without loss of dispensing quality. The minimum volume of droplets pneumatically dispensed using the plug-in dispenser was 124 nl with a coefficient of variation of 1.6%. The dispensed volume increased linearly with the nozzle size. Utilizing this linear relationship, two types of multinozzle dispensers consisting of six parallel channels (emerging from an inlet) and six nozzles were developed to demonstrate a novel strategy for volume gradient dispensing at a single operating condition. The droplet volume dispensed from each nozzle also increased linearly with nozzle size, demonstrating that nozzle size is a dominant factor on dispensed volume, even for multinozzle dispensing. Therefore, the proposed plug-in dispenser enables flexible design of nozzles and reversible integration to dispense droplets with different volumes, depending on the application. Furthermore, to demonstrate the practicality of the proposed dispensing system, we developed a pencil-type dispensing system as an alternative to a conventional pipette for rapid and reliable dispensing of minute volume droplets.

  12. Plug-in nanoliter pneumatic liquid dispenser with nozzle design flexibility

    PubMed Central

    Choi, In Ho; Kim, Hojin; Lee, Sanghyun; Baek, Seungbum; Kim, Joonwon

    2015-01-01

    This paper presents a novel plug-in nanoliter liquid dispensing system with a plug-and-play interface for simple and reversible, yet robust integration of the dispenser. A plug-in type dispenser was developed to facilitate assembly and disassembly with an actuating part through efficient modularization. The entire process for assembly and operation of the plug-in dispenser is performed via the plug-and-play interface in less than a minute without loss of dispensing quality. The minimum volume of droplets pneumatically dispensed using the plug-in dispenser was 124 nl with a coefficient of variation of 1.6%. The dispensed volume increased linearly with the nozzle size. Utilizing this linear relationship, two types of multinozzle dispensers consisting of six parallel channels (emerging from an inlet) and six nozzles were developed to demonstrate a novel strategy for volume gradient dispensing at a single operating condition. The droplet volume dispensed from each nozzle also increased linearly with nozzle size, demonstrating that nozzle size is a dominant factor on dispensed volume, even for multinozzle dispensing. Therefore, the proposed plug-in dispenser enables flexible design of nozzles and reversible integration to dispense droplets with different volumes, depending on the application. Furthermore, to demonstrate the practicality of the proposed dispensing system, we developed a pencil-type dispensing system as an alternative to a conventional pipette for rapid and reliable dispensing of minute volume droplets. PMID:26594263

  13. Contact dermatitis to Vicks VapoRub.

    PubMed

    Noiles, Kristin; Pratt, Melanie

    2010-01-01

    Vicks VapoRub (VVR) is a commonly used inhalant ointment that helps relieve symptoms of upper respiratory tract infections. It contains several plant substances, including turpentine oil, eucalyptus oil, and cedar leaf oil, which can potentially irritate or sensitize the skin, as well as camphor, menthol, nutmeg oil, and thymol. Although many reports describe allergic contact dermatitis (ACD) to the various constituents in VVR ointment, there are no cases of VVR directly causing ACD. We present a case of a patient who developed an ACD secondary to application of her VVR.

  14. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Rubbing alcohol general-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS DISTRIBUTION AND USE OF DENATURED ALCOHOL AND RUM...

  15. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Rubbing alcohol general-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS DISTRIBUTION AND USE OF DENATURED ALCOHOL AND RUM...

  16. Evaluation of the national Cleanyourhands campaign to reduce Staphylococcus aureus bacteraemia and Clostridium difficile infection in hospitals in England and Wales by improved hand hygiene: four year, prospective, ecological, interrupted time series study

    PubMed Central

    Fuller, Christopher; Savage, Joan; Cookson, Barry; Hayward, Andrew; Cooper, Ben; Duckworth, Georgia; Michie, Susan; Murray, Miranda; Jeanes, Annette; Roberts, J; Teare, Louise; Charlett, Andre

    2012-01-01

    Objective To evaluate the impact of the Cleanyourhands campaign on rates of hospital procurement of alcohol hand rub and soap, report trends in selected healthcare associated infections, and investigate the association between infections and procurement. Design Prospective, ecological, interrupted time series study from 1 July 2004 to 30 June 2008. Setting 187 acute trusts in England and Wales. Intervention Installation of bedside alcohol hand rub, materials promoting hand hygiene and institutional engagement, regular hand hygiene audits, rolled out nationally from 1 December 2004. Main outcome measures Quarterly (that is, every three months) rates for each trust of hospital procurement of alcohol hand rub and liquid soap; Staphylococcus aureus bacteraemia (meticillin resistant (MRSA) and meticillin sensitive (MSSA)) and Clostridium difficile infection for each trust. Associations between procurement and infection rates assessed by mixed effect Poisson regression model (which also accounted for effect of bed occupancy, hospital type, and timing of other national interventions targeting these infections). Results Combined procurement of soap and alcohol hand rub tripled from 21.8 to 59.8 mL per patient bed day; procurement rose in association with each phase of the campaign. Rates fell for MRSA bacteraemia (1.88 to 0.91 cases per 10 000 bed days) and C difficile infection (16.75 to 9.49 cases). MSSA bacteraemia rates did not fall. Increased procurement of soap was independently associated with reduced C difficile infection throughout the study (adjusted incidence rate ratio for 1 mL increase per patient bed day 0.993, 95% confidence interval 0.990 to 0.996; P<0.0001). Increased procurement of alcohol hand rub was independently associated with reduced MRSA bacteraemia, but only in the last four quarters of the study (0.990, 0.985 to 0.995; P<0.0001). Publication of the Health Act 2006 was strongly associated with reduced MRSA bacteraemia (0.86, 0.75 to 0.98; P=0

  17. Evaluation of the national Cleanyourhands campaign to reduce Staphylococcus aureus bacteraemia and Clostridium difficile infection in hospitals in England and Wales by improved hand hygiene: four year, prospective, ecological, interrupted time series study.

    PubMed

    Stone, Sheldon Paul; Fuller, Christopher; Savage, Joan; Cookson, Barry; Hayward, Andrew; Cooper, Ben; Duckworth, Georgia; Michie, Susan; Murray, Miranda; Jeanes, Annette; Roberts, J; Teare, Louise; Charlett, Andre

    2012-05-03

    To evaluate the impact of the Cleanyourhands campaign on rates of hospital procurement of alcohol hand rub and soap, report trends in selected healthcare associated infections, and investigate the association between infections and procurement. Prospective, ecological, interrupted time series study from 1 July 2004 to 30 June 2008. 187 acute trusts in England and Wales. Installation of bedside alcohol hand rub, materials promoting hand hygiene and institutional engagement, regular hand hygiene audits, rolled out nationally from 1 December 2004. Quarterly (that is, every three months) rates for each trust of hospital procurement of alcohol hand rub and liquid soap; Staphylococcus aureus bacteraemia (meticillin resistant (MRSA) and meticillin sensitive (MSSA)) and Clostridium difficile infection for each trust. Associations between procurement and infection rates assessed by mixed effect Poisson regression model (which also accounted for effect of bed occupancy, hospital type, and timing of other national interventions targeting these infections). Combined procurement of soap and alcohol hand rub tripled from 21.8 to 59.8 mL per patient bed day; procurement rose in association with each phase of the campaign. Rates fell for MRSA bacteraemia (1.88 to 0.91 cases per 10,000 bed days) and C difficile infection (16.75 to 9.49 cases). MSSA bacteraemia rates did not fall. Increased procurement of soap was independently associated with reduced C difficile infection throughout the study (adjusted incidence rate ratio for 1 mL increase per patient bed day 0.993, 95% confidence interval 0.990 to 0.996; P < 0.0001). Increased procurement of alcohol hand rub was independently associated with reduced MRSA bacteraemia, but only in the last four quarters of the study (0.990, 0.985 to 0.995; P < 0.0001). Publication of the Health Act 2006 was strongly associated with reduced MRSA bacteraemia (0.86, 0.75 to 0.98; P = 0.02) and C difficile infection (0.75, 0.67 to 0.84; P < 0

  18. Turbine Engine Stability/Instability With Rub Forces Axisymmetric Rotor-Support Stiffness

    NASA Technical Reports Server (NTRS)

    Gallardo, Vicente; Lawrence, Charles

    2004-01-01

    The stability/instability condition of a turbine rotor with axisymmetric supports is determined in the presence of gyroscopic loads and rub-induced destabilizing forces. A modal representation of the turbine engine is used, with one mode in each of the vertical and horizontal planes. The use of non-spinning rotor modes permits an explicit treatment of gyroscopic effects. The two linearized modal equations of motion of a rotor with axisymmetric supports are reduced to a single equation in a complex variable. The resulting eigenvalues yield explicit expressions at the stability boundary, for the whirl frequency as well as the required damping for stability in the presence of the available rub-induced destabilization. Conversely, the allowable destabilization in the presence of the available damping is also given.

  19. 17. Jet Lowe, Photographer, June 1978. FIVEROLL RUB DELIVERY ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. Jet Lowe, Photographer, June 1978. FIVE-ROLL RUB DELIVERY ON A. JENKS & SON FINISHER CARD; THE DELIVERY IS CONSISTENT WITH MANUFACTURE C. 1845-1855; FROM RIGHT FRONT OF OSCILLATING MECHANISM. - Watkins Mill, County Highway MM, Lawson, Ray County, MO

  20. Head rubbing and licking reinforce social bonds in a group of captive African lions, Panthera leo.

    PubMed

    Matoba, Tomoyuki; Kutsukake, Nobuyuki; Hasegawa, Toshikazu

    2013-01-01

    Many social animals have a species-specific repertoire of affiliative behaviours that characterise individualised relationships within a group. To date, however, quantitative studies on intragroup affiliative behaviours in social carnivores have been limited. Here, we investigated the social functions of the two most commonly observed affiliative behaviours in captive African lions (Panthera leo): head rubbing and licking. We conducted behavioural observations on a captive group of lions composed of 7 males and 14 females, and tested hypotheses regarding three social functions: tension reduction, social bonding, and social status expression. Disproportionately frequent male-male and female-to-male head rubbing was observed, while more than 95% of all licking interactions occurred in female-female dyads. In accordance with the social bond hypothesis, and in disagreement with the social status expression hypothesis, both head rubbing and licking interactions were reciprocal. After controlling for spatial association, the dyadic frequency of head rubbing was negatively correlated with age difference while licking was positively correlated with relatedness. Group reunion after daily separation did not affect the frequencies of the affiliative behaviours, which was in disagreement with the predictions from the tension reduction hypothesis. These results support the social bond hypothesis for the functions of head rubbing and licking. Different patterns of affiliative behaviour between the sexes may reflect differences in the relationship quality in each sex or the differential predisposition to licking due to its original function in offspring care.

  1. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (2) made in accordance with one of the two formulas prescribed in paragraph (b) of this section, and...-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Formulas and Statements of Process General-Use Formulas § 20.118 Rubbing alcohol general-use formula. (a...

  2. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (2) made in accordance with one of the two formulas prescribed in paragraph (b) of this section, and...-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Formulas and Statements of Process General-Use Formulas § 20.118 Rubbing alcohol general-use formula. (a...

  3. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (2) made in accordance with one of the two formulas prescribed in paragraph (b) of this section, and...-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Formulas and Statements of Process General-Use Formulas § 20.118 Rubbing alcohol general-use formula. (a...

  4. Structural geology of the Rub' Al-Khali Basin, Saudi Arabia

    NASA Astrophysics Data System (ADS)

    Stewart, S. A.

    2016-10-01

    The Rub' Al-Khali basin lies below a Quaternary sand sea, and the structural evolution from the Late Precambrian to Neogene is known only from reflection seismic, gravity, and magnetic data, and wells. Gravity and magnetic data show north-south and northwest-southeast trends, matching mapped Precambrian faults. The deepest structures imaged on reflection seismic data are undrilled Precambrian rifts filled with layered strata at depths up to 13 km. The distribution of Ediacaran-Cambrian Ara/Hormuz mobile salt is restricted to an embayment in the eastern Rub' Al-Khali. The Precambrian rifts show local inversion and were peneplained at base Phanerozoic. A broad crustal-scale fold (Qatar Arch) developed in the Carboniferous and amplified in the Late Triassic, separating subbasins in the west and east Rub' Al-Khali. A phase of kilometer-scale folding occurred in the Late Cretaceous, coeval with thrusting and ophiolite obduction in eastern Oman. These folds trend predominantly north-south, oblique to the northwesterly shortening direction, and occasionally have steep fault zones close to their axial surfaces. The trend and location of these folds closely matches the Precambrian lineaments identified in this study, demonstrating preferential reactivation of basement structures. Compression along the Zagros suture reactivated these folds in the Neogene, this time the result of highly oblique, north-northeast to south-southwest shortening. Cretaceous-Tertiary fold style is interpreted as transpression with minor strain partitioning. Permian, Jurassic, and Eocene evaporite horizons played no role in the structural evolution of the basin, but the Eocene evaporites caused widespread kilometer-scale dissolution collapse structures in the basin center.

  5. The hammer QSD-quick stop device for high speed machining and rubbing

    NASA Technical Reports Server (NTRS)

    Black, J. T.; James, C. R.

    1980-01-01

    A quick stop device (QSD) was designed for use in orthogonal machining and rubbing experiments. QSD's are used to obtain chip root samples that are representative of the deformation taking place during dynamic (actual) cutting conditions. These 'frozen' specimens are helpful in examining the plastic deformation that occurs in the regions of compression and shear which form the chip; the secondary shear at the tool-chip interface; and the nose ploughing/flank rubbing action which operates on the newly machined surface. The Hammer QSD employs a shear pin mechanism, broken by a flying hammer, which is traveling at the same velocity as the workpiece. The device has been successfully tested up to 6000 sfpm (30.48 m/sec).

  6. Antimicrobial efficacy of alcohol-based hand gels.

    PubMed

    Guilhermetti, M; Marques Wiirzler, L A; Castanheira Facio, B; da Silva Furlan, M; Campo Meschial, W; Bronharo Tognim, M C; Botelho Garcia, L; Luiz Cardoso, C

    2010-03-01

    In recent years, several commercial alcohol-based hand gels have appeared on the market to improve the hand-cleansing compliance of healthcare workers. Although the antimicrobial efficacy of these products has been reported in different countries, few studies have investigated this subject in Brazil. In this study, we assessed the antimicrobial efficacy of 12 alcohol-based hand gels produced in Brazil, containing 70% w/w or v/v ethyl alcohol as the active ingredient, according to the European Standard EN 1500 (EN 1500). The following alcohol gels were tested: Hand Gel, Voga Gel, Solumax Solugel, Doctor Clean, Rio Gel, Clear Gel, Sevengel, Hand CHC, Gel Bac, WBL-50 Gel, Sanigel and Soft Care Gel. In addition, 70% w/w ethyl alcohol and three alcohol-based hand rubs (Sterillium, Sterillium Gel, and Spitaderm), commonly used in Europe and effective according to EN 1500, were also tested. All the products tested, except for two, were approved by the EN 1500 test protocol with a 60s application. The results confirmed the antimicrobial efficacy of the majority of the alcohol gels produced in Brazil for hand hygiene of healthcare workers. Copyright 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  7. Analytical and experimental investigation of rubbing interaction in labyrinth seals for a liquid hydrogen fuel pump. [space shuttle main engine

    NASA Technical Reports Server (NTRS)

    Dolan, F. X.; Kennedy, F. E.; Schulson, E. M.

    1984-01-01

    Cracking of the titanium knife edges on the labyrinth seals of the liquid hydrogen fuel pump in the Space Shuttle main engine is considered. Finite element analysis of the thermal response of the knife edge in sliding contact with the wear ring surface shows that interfacial temperatures can be quite high and they are significantly influenced by the thermal conductivity of the surfaces in rubbing contact. Thermal shock experiments on a test specimen similar to the knife edge geometry demonstrate that cracking of the titanium alloy is possible in a situation involving repeated thermal cycles over a wide temperature range, as might be realized during a rub in the liquid hydrogen fuel pump. High-speed rub interaction tests were conducted using a representative knife edge and seal geometry over a broad range of interaction rates and alternate materials were experimentally evaluated. Plasma-sprayed aluminum-graphite was found to be significantly better than presently used aluminum alloy seals from the standpoint of rub performance. Ion nitriding the titanium alloy knife-edges also improved rub performance compared to the untreated baseline.

  8. Who dispenses pharmaceuticals to children at school?

    PubMed

    Francis, E E; Hemmat, J P; Treloar, D M; Yarandi, H

    1996-12-01

    Use of both prescription and non-prescription pharmaceuticals has increased among children. Many of these drugs are taken during school hours and dispensed by school personnel who are not health professionals. They know little or nothing about the drugs themselves or the medical conditions requiring their use. This survey examined the extent to which pharmaceuticals are dispensed in schools in one Florida county. Public elementary, middle, and high schools and six private schools were surveyed for one week. All medications dispensed by school personnel during that time were recorded. Of 28,134 children surveyed, 1,016 children received 5,411 doses of medication. Thirty-one categories of drugs were dispensed including controlled substances. Methylphenidate was the most widely dispensed drug, comprising about half of all the medications given in school. Medication use was evaluated in terms of gender, race, and socioeconomic status of the children.

  9. Piezo- and solenoid valve-based liquid dispensing for miniaturized assays.

    PubMed

    Niles, Walter D; Coassin, Peter J

    2005-04-01

    Miniaturization of biological assays requires dispensing liquids in the submicroliter range of volumes. Accuracy and reproducibility of dispensing this range depend on both the dispenser and the receptacle in which the assay is constructed. Miniaturization technologies developed by Aurora Discovery, Inc. (San Diego, CA) include high-density multiwell plates for assay samples and reagent storage, as well as piezo-based and solenoid valve-based liquid dispensers. Some basic principles of small-volume dispensing by jetting are described to provide context for dispenser design and function. Performance of the latest instruments incorporating these dispensing devices is presented.

  10. Isolation of Raoultella planticola from refillable antimicrobial liquid soap dispensers in a dental setting.

    PubMed

    Momeni, Stephanie S; Tomlin, Nancy; Ruby, John D

    2015-04-01

    Liquid antimicrobial soaps are commonly used in the dental health care setting for hand washing to minimize the potential spread of infectious agents to health care workers and patients. The purpose of the current study was to evaluate possible bacterial contamination of antimicrobial liquid soap dispensers located in 2 institutional comprehensive dental care clinics. Fourteen soap dispensers and 16 original stock containers were sampled. A 1-milliliter aliquot was diluted in 10 mL of phosphate buffer (Tween-80; Acros). Serial dilutions were plated in duplicate on neutralizing agar and incubated for 7 days. Molecular identification was performed using 500 base pair comparisons of 16S ribosomal ribonucleic acid sequencing. Taq polymerase chain reaction was performed with sequence-specific primers for Raoultella species. Bacterial growth was observed at 18 hours for 57% (8 of 14) of soap dispenser samples. Bacterial densities ranged from 4 × 10(2) to 6 × 10(9) colony-forming units per milliliter. Original commercial containers exhibited no growth. Isolates were identified as Raoultella (Klebsiella) planticola. This is the first study to the authors' knowledge indicating recovery of R. planticola from antimicrobial liquid soap dispensers. R. planticola is a recognized environmental opportunistic pathogen that potentially poses a health concern. These findings indicate compliance problems with infection prevention recommendations and support the US Centers for Disease Control and Prevention's recommendation that dispensers should not be topped off. High bacterial loads of R. planticola are inconsistent with infection control practices and are a concern because transmission and possible infection to the health care worker or the patient may occur. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  11. Comparing mating disruption of codling moth with standard and meso dispensers loaded with pear ester and codlemone

    USDA-ARS?s Scientific Manuscript database

    Studies were conducted with hand-applied combo dispensers loaded with the sex pheromone (E,E)-8,10-dodecadien-1-ol (codlemone), and the pear volatile, (E,Z)-2,4-decadienoate (pear ester) for control of codling moth, Cydia pomonella (L.) in apple, Malus domestica Bordkhausen during 2012. Two types of...

  12. Evaluation and remediation of bulk soap dispensers for biofilm.

    PubMed

    Lorenz, Lindsey A; Ramsay, Bradley D; Goeres, Darla M; Fields, Matthew W; Zapka, Carrie A; Macinga, David R

    2012-01-01

    Recent studies evaluating bulk soap in public restroom soap dispensers have demonstrated up to 25% of open refillable bulk-soap dispensers were contaminated with ~ 6 log(10)(CFU ml(-1)) heterotrophic bacteria. In this study, plastic counter-mounted, plastic wall-mounted and stainless steel wall-mounted dispensers were analyzed for suspended and biofilm bacteria using total cell and viable plate counts. Independent of dispenser type or construction material, the bulk soap was contaminated with 4-7 log(10)(CFU ml(-1)) bacteria, while 4-6 log(10)(CFU cm(-2)) biofilm bacteria were isolated from the inside surfaces of the dispensers (n = 6). Dispenser remediation studies, including a 10 min soak with 5000 mg l(-1) sodium hypochlorite, were then conducted to determine the efficacy of cleaning and disinfectant procedures against established biofilms. The testing showed that contamination of the bulk soap returned to pre-test levels within 7-14 days. These results demonstrate biofilm is present in contaminated bulk-soap dispensers and remediation studies to clean and sanitize the dispensers are temporary.

  13. 30 CFR 71.603 - Drinking water; dispensing requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Drinking water; dispensing requirements. 71.603... COAL MINES Drinking Water § 71.603 Drinking water; dispensing requirements. (a) Water shall be dispensed through a drinking fountain or from a water storage container with an adequate supply of single...

  14. 30 CFR 71.603 - Drinking water; dispensing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Drinking water; dispensing requirements. 71.603... COAL MINES Drinking Water § 71.603 Drinking water; dispensing requirements. (a) Water shall be dispensed through a drinking fountain or from a water storage container with an adequate supply of single...

  15. 30 CFR 71.603 - Drinking water; dispensing requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Drinking water; dispensing requirements. 71.603... COAL MINES Drinking Water § 71.603 Drinking water; dispensing requirements. (a) Water shall be dispensed through a drinking fountain or from a water storage container with an adequate supply of single...

  16. 30 CFR 71.603 - Drinking water; dispensing requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Drinking water; dispensing requirements. 71.603... COAL MINES Drinking Water § 71.603 Drinking water; dispensing requirements. (a) Water shall be dispensed through a drinking fountain or from a water storage container with an adequate supply of single...

  17. 30 CFR 71.603 - Drinking water; dispensing requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Drinking water; dispensing requirements. 71.603... COAL MINES Drinking Water § 71.603 Drinking water; dispensing requirements. (a) Water shall be dispensed through a drinking fountain or from a water storage container with an adequate supply of single...

  18. A Simulated Learning Environment for Teaching Medicine Dispensing Skills

    PubMed Central

    Styles, Kim; Sewell, Keith; Trinder, Peta; Marriott, Jennifer; Maher, Sheryl; Naidu, Som

    2016-01-01

    Objective. To develop an authentic simulation of the professional practice dispensary context for students to develop their dispensing skills in a risk-free environment. Design. A development team used an Agile software development method to create MyDispense, a web-based simulation. Modeled on virtual learning environments elements, the software employed widely available standards-based technologies to create a virtual community pharmacy environment. Assessment. First-year pharmacy students who used the software in their tutorials, were, at the end of the second semester, surveyed on their prior dispensing experience and their perceptions of MyDispense as a tool to learn dispensing skills. Conclusion. The dispensary simulation is an effective tool for helping students develop dispensing competency and knowledge in a safe environment. PMID:26941437

  19. [Briefly analysis on academic origins of traditional Chinese medicine dispensing].

    PubMed

    Zhao, Xue-Min; Zhang, Xiao-Juan; Zhai, Hua-Qiang; Jin, Shi-Yuan

    2014-04-01

    Through collecting and collating the development process of traditional Chinese medicine dispensing, the development of modern Chinese medicine dispensing on the basis of experience could be promoted. "Heyaofenji", "Hehe", " Heji" in ancient Chinese medicine, herbal medicine literature and law were collected, and then things were sorted out according to traditional Chinese medicine dispensing theory, skills and legal norms. Firstly, "Tang Ye Jing Fa" is the earliest book which marks the rudiment of traditional Chinese medicine dispensing. Secondly, traditional Chinese medicine dispensing theory formed in "Shen Nong's herbal classic". Thirdly, Zhang Zhongjing's "Treatise on Febrile Diseases" marked the formation of Chinese medicine dispensing skills. Lastly, Provisions in Tang Dynasty law marks the development of traditional Chinese medicine dispensing.

  20. A finite element-based algorithm for rubbing induced vibration prediction in rotors

    NASA Astrophysics Data System (ADS)

    Behzad, Mehdi; Alvandi, Mehdi; Mba, David; Jamali, Jalil

    2013-10-01

    In this paper, an algorithm is developed for more realistic investigation of rotor-to-stator rubbing vibration, based on finite element theory with unilateral contact and friction conditions. To model the rotor, cross sections are assumed to be radially rigid. A finite element discretization based on traditional beam theories which sufficiently accounts for axial and transversal flexibility of the rotor is used. A general finite element discretization model considering inertial and viscoelastic characteristics of the stator is used for modeling the stator. Therefore, for contact analysis, only the boundary of the stator is discretized. The contact problem is defined as the contact between the circular rigid cross section of the rotor and “nodes” of the stator only. Next, Gap function and contact conditions are described for the contact problem. Two finite element models of the rotor and the stator are coupled via the Lagrange multipliers method in order to obtain the constrained equation of motion. A case study of the partial rubbing is simulated using the algorithm. The synchronous and subsynchronous responses of the partial rubbing are obtained for different rotational speeds. In addition, a sensitivity analysis is carried out with respect to the initial clearance, the stator stiffness, the damping parameter, and the coefficient of friction. There is a good agreement between the result of this research and the experimental result in the literature.

  1. Chromosome-Encoded Broad-Spectrum Ambler Class A β-Lactamase RUB-1 from Serratia rubidaea

    PubMed Central

    Didi, Jennifer; Ergani, Ayla; Lima, Sandra

    2016-01-01

    ABSTRACT Whole-genome sequencing of Serratia rubidaea CIP 103234T revealed a chromosomally located Ambler class A β-lactamase gene. The gene was cloned, and the β-lactamase, RUB-1, was characterized. RUB-1 displayed 74% and 73% amino acid sequence identity with the GIL-1 and TEM-1 penicillinases, respectively, and its substrate profile was similar to that of the latter β-lactamases. Analysis by 5′ rapid amplification of cDNA ends revealed promoter sequences highly divergent from the Escherichia coli σ70 consensus sequence. This work further illustrates the heterogeneity of β-lactamases among Serratia spp. PMID:27956418

  2. 21 CFR 872.3080 - Mercury and alloy dispenser.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mercury and alloy dispenser. 872.3080 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3080 Mercury and alloy dispenser. (a) Identification. A mercury and alloy dispenser is a device with a spring-activated valve intended to measure and...

  3. 21 CFR 872.3080 - Mercury and alloy dispenser.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Mercury and alloy dispenser. 872.3080 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3080 Mercury and alloy dispenser. (a) Identification. A mercury and alloy dispenser is a device with a spring-activated valve intended to measure and...

  4. 21 CFR 872.3080 - Mercury and alloy dispenser.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Mercury and alloy dispenser. 872.3080 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3080 Mercury and alloy dispenser. (a) Identification. A mercury and alloy dispenser is a device with a spring-activated valve intended to measure and...

  5. 21 CFR 872.3080 - Mercury and alloy dispenser.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Mercury and alloy dispenser. 872.3080 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3080 Mercury and alloy dispenser. (a) Identification. A mercury and alloy dispenser is a device with a spring-activated valve intended to measure and...

  6. Dispensing of non-prescribed antibiotics in Jordan

    PubMed Central

    Almaaytah, Ammar; Mukattash, Tareq L; Hajaj, Julia

    2015-01-01

    Objective Current regulations in Jordan state that antibiotics cannot be sold without a medical prescription. This study aimed to assess the percentage of pharmacies that dispense antibiotics without a medical prescription in the Kingdom of Jordan and identify and highlight the extent and seriousness of such practices among Jordanian pharmacies. Methods A prospective study was performed, and five different clinical scenarios were simulated at pharmacies investigated including sore throat, otitis media, acute sinusitis, diarrhea, and urinary tract infection in childbearing-aged women. Three levels of demand were used to convince the pharmacists to sell an antibiotic. Results A total of 202 total pharmacies in Jordan were visited in the present study. The majority of pharmacies (74.3%) dispensed antibiotics without prescription with three different levels of demand. The percentage of pharmacies dispensing antibiotics without a prescription for the sore throat scenario was 97.6%, followed by urinary tract infection (83.3%), diarrhea (83%), and otitis media (68.4%). The lowest percentage of antibiotic dispensing was for the acute sinusitis simulation at 48.5%. Among the pharmacies that dispensed antibiotics, the pharmacists provided an explanation as the number of times per day the drug should be taken in 95.3% of the cases, explained the duration of treatment in 25.7%, and inquired about allergies prior to the sale of the antibiotic in only 17.3%. Only 52 pharmacies (25.7%) refused to dispense any kind of antibiotics, the majority (61.5%) of this refusal response came from acute sinusitis cases, while the minority (2.4%) came from the sore throat cases. Conclusion The results of this study demonstrate that antibiotics continue to be dispensed without prescription in Jordan in violation with national regulations regarding this practice. The findings of this study could provide a layout for governmental health authorities to implement strict enfrorcment of national

  7. How often are spectacle lenses not dispensed as prescribed?

    PubMed

    Mohan, Kanwar; Sharma, Ashok

    2012-01-01

    Spectacles are routinely prescribed by the ophthalmologist and dispensed by the opticians. We investigated how frequently the spectacles are not dispensed as prescribed and whether the frequency of inaccurate spectacles would decrease if the patients, at the time of collecting spectacles, ask the optician to verify that the spectacles have been dispensed accurately. We found inaccurate spectacles in about one-third of our patients and incorrect spherocylinders more frequently with an error in the spherical element and cylinder axis. These inaccuracies decreased significantly when patients while collecting spectacles, asked the optician to verify the accuracy of the spectacles dispensed. It is suggested that while prescribing spectacles, the patients should be made aware of the possibility of dispensing errors. To decrease the frequency of incorrect spectacles, the patients while collecting spectacles, should ask the optician to check whether the spectacles have been dispensed accurately.

  8. Chromosome-Encoded Broad-Spectrum Ambler Class A β-Lactamase RUB-1 from Serratia rubidaea.

    PubMed

    Bonnin, Rémy A; Didi, Jennifer; Ergani, Ayla; Lima, Sandra; Naas, Thierry

    2017-02-01

    Whole-genome sequencing of Serratia rubidaea CIP 103234 T revealed a chromosomally located Ambler class A β-lactamase gene. The gene was cloned, and the β-lactamase, RUB-1, was characterized. RUB-1 displayed 74% and 73% amino acid sequence identity with the GIL-1 and TEM-1 penicillinases, respectively, and its substrate profile was similar to that of the latter β-lactamases. Analysis by 5' rapid amplification of cDNA ends revealed promoter sequences highly divergent from the Escherichia coli σ 70 consensus sequence. This work further illustrates the heterogeneity of β-lactamases among Serratia spp. Copyright © 2017 American Society for Microbiology.

  9. Metering gun for dispensing precisely measured charges of fluid

    NASA Technical Reports Server (NTRS)

    Cook, T. A.; Scheibe, H. (Inventor)

    1974-01-01

    A cyclically operable fluid dispenser for use in dispensing precisely measured charges of potable water aboard spacecraft is described. The dispenser is characterized by (1) a sealed housing adapted to be held within a crewman's palm and coupled with a pressurized source of potable water; (2) a dispensing jet projected from the housing and configured to be received within a crewman's lips; (3) an expansible measuring chamber for measuring charges of drinking water received from the source; (4) and a dispenser actuator including a lever extended from the housing to be digitated for initiating operational cycles, whereby precisely measured charges of potable water selectively are delivered for drinking purposes in a weightless environment.

  10. Improving outpatient primary medication adherence with physician guided, automated dispensing

    PubMed Central

    Moroshek, Jacob G

    2017-01-01

    Background Physician dispensing, different from pharmacist dispensing, is a way for practitioners to supply their patients with medications, at the point of care. The InstyMeds dispenser and logistics system can automate much of the dispensing, insurance adjudication, inventory management, and regulatory reporting that is required of physician dispensing. Objective To understand the percentage of patients that exhibit primary adherence to medication in the outpatient setting when choosing InstyMeds. Method The InstyMeds dispensing database was de-identified and analyzed for primary adherence. This is the ratio of patients who dispensed their medication to those who received an eligible prescription. Results The average InstyMeds emergency department installation has a primary adherence rate of 91.7%. The maximum rate for an installed device was 98.5%. Conclusion Although national rates of primary adherence have been found to be in the range of 70%, automated physician dispensing vastly improves the rate of adherence. Improved adherence should lead to better patient outcomes, fewer return visits, and lower healthcare costs. PMID:28115860

  11. Task Analysis in Optical & Contact Lens Dispensing. Dispensing Opticians.

    ERIC Educational Resources Information Center

    Hrushowy, Eugene; Stanley, Dale

    A task force of opticians and educators in British Columbia was assembled to determine the knowledge and skills required of dispensing opticians and contact lens specialists. The ideas generated by the task force were analyzed and distilled into the standardized tasks listed in this document, using Krathwohl's taxonomy. The document contains 36…

  12. A recessive mutation in the RUB1-conjugating enzyme, RCE1, reveals a requirement for RUB modification for control of ethylene biosynthesis and proper induction of basic chitinase and PDF1.2 in Arabidopsis.

    PubMed

    Larsen, Paul B; Cancel, Jesse D

    2004-05-01

    By screening etiolated Arabidopsis seedlings for mutants with aberrant ethylene-related phenotypes, we identified a mutant that displays features of the ethylene-mediated triple response even in the absence of ethylene. Further characterization showed that the phenotype observed for the dark-grown seedlings of this mutant is reversible by prevention of ethylene perception and is dependent on a modest increase in ethylene production correlated with an increase in 1-aminocyclopropane-1-carboxylic acid (ACC) oxidase (ACO) activity in the hypocotyl. Molecular characterization of leaves of the mutant revealed severely impaired induction of basic chitinase (chiB) and plant defensin (PDF)1.2 following treatment with jasmonic acid and/or ethylene. Positional cloning of the mutation resulted in identification of a 49-bp deletion in RCE1 (related to ubiquitin 1 (RUB1)-conjugating enzyme), which has been demonstrated to be responsible for covalent attachment of RUB1 to the SCF (Skpl Cdc 53 F-box) ubiquitin ligase complex to modify its activity. Our analyses with rce1-2 demonstrate a previously unknown requirement for RUB1 modification for regulation of ethylene biosynthesis and proper induction of defense-related genes in Arabidopsis.

  13. Structure Design and Realization of Rapid Medicine Dispensing System

    NASA Astrophysics Data System (ADS)

    Liu, Xiangquan

    In this paper, the main components and function of rapid medicine dispensing system is analyzed, structure design of automatic feeding device, sloping storeroom, automatic dispensing device and automatic sorting device is completed. The system adopts medicine conveyer working in with manipulator to realize automatic batch supply of the boxed medicine, adopts sloping storeroom as warehouse of medicine to realize dense depositing, adopts dispensing mechanism which includes elevator, turning panel and electric magnet to realize rapid medicine dispensing, adopts sorting conveyor belt and sorting device to send medicine to designated outlet.

  14. Triple dye plus rubbing alcohol versus triple dye alone for umbilical cord care.

    PubMed

    Suliman, Alawia K; Watts, Heidi; Beiler, Jessica; King, Tonya S; Khan, Sana; Carnuccio, Marybeth; Paul, Ian M

    2010-01-01

    Current practices for umbilical cord care vary across centers, but the evidence regarding these practices and their impact on cord separation, complications, and health care use are limited. The objective of this study was to compare the effect of triple dye alone (brilliant green, crystal violet, and proflavine hemisulfate) versus triple dye plus rubbing alcohol (isopropyl alcohol) twice daily on time to umbilical cord separation, complications, and health care use. For the 90 newborns who completed the study, there were no significant differences between treatment groups for time to cord separation, cord-related morbidities, or cord-related urgent care. Based on these study results, there does not appear to be significant benefit to the addition of twice daily applications of rubbing alcohol to neonatal umbilical cords following triple dye treatment after birth.

  15. In vitro-in vivo sequence studies as a method of selecting the most efficacious alcohol-based solution for hygienic hand disinfection.

    PubMed

    Herruzo, R; Vizcaino, M J; Herruzo, I

    2010-05-01

    The use of alcohol-based hand rubs serves to reduce hospital-acquired infections. Many products of this type are now on offer and it is essential to know how to rank their efficacy. A sequence of tests is proposed here to compare any given new alcohol-based solution against the reference solution (60% 2-isopropyl-alcohol) with 30 s of contact time: (i) in vitro (with pig skin as carrier) testing of >30 species of microorganism; (ii) in vitro assessment of residual efficacy (after 30 min of drying); (iii) in vivo study of transient microbiota (modification of the EN 1500 standard procedure) using four ATCC strains; (iv) in vivo study of resident hand microbiota. After performing the in vitro evaluation of seven alcohol-based hand rubs, the two most efficacious (chlorhexidine-quac-alcohol and mecetronium- alcohol) were chosen and studied, comparatively with the reference solution (60% isopropyl alcohol), in vitro (for chemical sustainability on the skin) and in vivo (against transient and resident microbiota). Chlorhexidine-quac-alcohol proved to be significantly superior to mecetronium-alcohol or the reference solution in all tests, except against resident microbiota for which the improvement was not statistically significant.

  16. Intensified hand-hygiene campaign including soap-and-water wash may prevent acute infections in office workers, as shown by a recognized-exposure -adjusted analysis of a randomized trial.

    PubMed

    Hovi, Tapani; Ollgren, Jukka; Savolainen-Kopra, Carita

    2017-01-09

    Variable exposure to causative agents of acute respiratory (RTI) or gastrointestinal tract infections (GTI) is a significant confounding factor in the analysis of the efficacy of interventions concerning these infections. We had an exceptional opportunity to reanalyze a previously published dataset from a trial assessing the effect of enhanced hand hygiene on the occurrence of RTI or GTI in adults, after adjustment for reported exposure and other covariates. Twenty-one working units (designated clusters) each including at least 50 office employees, totaling 1,270 persons, were randomized into two intervention arms (either using water-and-soap or alcohol-rub in hand cleansing), or in the control arm. Self-reported data was collected through weekly emails and included own symptoms of RTI or GTI, and exposures to other persons with similar symptoms. Differences in the weekly occurrences of RTI and GTI symptoms between the arms were analyzed using multilevel binary regression model with log link with personal and cluster specific random effects, self-reported exposure to homologous disease, randomization triplet, and seasonality as covariates in the Bayesian framework. Over the 16 months duration of the trial, 297 persons in the soap and water arm, 238 persons in the alcohol-based hand rub arm, and 230 controls sent reports. The arms were similar in age distribution and gender ratios. A temporally-associated reported exposure strongly increased the risk of both types of infection in all trial arms. Persons in the soap-and-water arm reported a significantly - about 24% lower weekly prevalence of GTI than the controls whether they had observed an exposure or not during the preceding week, while for RTI, this intervention reduced the prevalence only during weeks without a reported exposure. Alcohol-rub did not affect the symptom prevalence. We conclude that while frequent and careful hand washing with soap and water partially protected office-working adults from GTI, the

  17. 21 CFR 872.3080 - Mercury and alloy dispenser.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3080 Mercury and alloy dispenser. (a... dispense into a mixing capsule a predetermined amount of dental mercury in droplet form and a premeasured...

  18. 21 CFR 1306.26 - Dispensing without prescription.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Federal Food, Drug, and Cosmetic Act, may be dispensed by a pharmacist without a prescription to a purchaser at retail, provided that: (a) Such dispensing is made only by a pharmacist (as defined in part... pharmacist (although after the pharmacist has fulfilled his professional and legal responsibilities set forth...

  19. 21 CFR 1306.26 - Dispensing without prescription.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Federal Food, Drug, and Cosmetic Act, may be dispensed by a pharmacist without a prescription to a purchaser at retail, provided that: (a) Such dispensing is made only by a pharmacist (as defined in part... pharmacist (although after the pharmacist has fulfilled his professional and legal responsibilities set forth...

  20. 21 CFR 1306.26 - Dispensing without prescription.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Federal Food, Drug, and Cosmetic Act, may be dispensed by a pharmacist without a prescription to a purchaser at retail, provided that: (a) Such dispensing is made only by a pharmacist (as defined in part... pharmacist (although after the pharmacist has fulfilled his professional and legal responsibilities set forth...

  1. 21 CFR 1306.26 - Dispensing without prescription.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Federal Food, Drug, and Cosmetic Act, may be dispensed by a pharmacist without a prescription to a purchaser at retail, provided that: (a) Such dispensing is made only by a pharmacist (as defined in part... pharmacist (although after the pharmacist has fulfilled his professional and legal responsibilities set forth...

  2. 21 CFR 1306.26 - Dispensing without prescription.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Federal Food, Drug, and Cosmetic Act, may be dispensed by a pharmacist without a prescription to a purchaser at retail, provided that: (a) Such dispensing is made only by a pharmacist (as defined in part... pharmacist (although after the pharmacist has fulfilled his professional and legal responsibilities set forth...

  3. 14 CFR 137.39 - Economic poison dispensing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Economic poison dispensing. 137.39 Section... AIRCRAFT OPERATIONS Operating Rules § 137.39 Economic poison dispensing. (a) Except as provided in... economic poison that is registered with the U.S. Department of Agriculture under the Federal Insecticide...

  4. 14 CFR 137.39 - Economic poison dispensing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Economic poison dispensing. 137.39 Section... AIRCRAFT OPERATIONS Operating Rules § 137.39 Economic poison dispensing. (a) Except as provided in... economic poison that is registered with the U.S. Department of Agriculture under the Federal Insecticide...

  5. 14 CFR 137.39 - Economic poison dispensing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Economic poison dispensing. 137.39 Section... AIRCRAFT OPERATIONS Operating Rules § 137.39 Economic poison dispensing. (a) Except as provided in... economic poison that is registered with the U.S. Department of Agriculture under the Federal Insecticide...

  6. 14 CFR 137.39 - Economic poison dispensing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Economic poison dispensing. 137.39 Section... AIRCRAFT OPERATIONS Operating Rules § 137.39 Economic poison dispensing. (a) Except as provided in... economic poison that is registered with the U.S. Department of Agriculture under the Federal Insecticide...

  7. 14 CFR 137.39 - Economic poison dispensing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Economic poison dispensing. 137.39 Section... AIRCRAFT OPERATIONS Operating Rules § 137.39 Economic poison dispensing. (a) Except as provided in... economic poison that is registered with the U.S. Department of Agriculture under the Federal Insecticide...

  8. Gas Chromatographic Determination of Methyl Salicylate in Rubbing Alcohol: An Experiment Employing Standard Addition.

    ERIC Educational Resources Information Center

    Van Atta, Robert E.; Van Atta, R. Lewis

    1980-01-01

    Provides a gas chromatography experiment that exercises the quantitative technique of standard addition to the analysis for a minor component, methyl salicylate, in a commercial product, "wintergreen rubbing alcohol." (CS)

  9. Why language matters: a tour through hand hygiene literature.

    PubMed

    Pires, Daniela; Tartari, Ermira; Bellissimo-Rodrigues, Fernando; Pittet, Didier

    2017-01-01

    Hand hygiene has evolved over the last decades and many terminologies emerged. We aimed to analyse the evolution in the frequency of utilization of key hand hygiene terms in the literature along the years. We identified keywords and Medical Subject Headings (MeSH) used in MEDLINE® indexation related to hand hygiene by searching international guidelines and the MeSH database. We performed a MEDLINE® search combining the selected keywords and MeSH and analysed the number of publications retrieved yearly. The literature search yielded 9019 publications when all hand hygiene related search terms were combined, between 1921 and November 2016. The total number of publications per year increased from a median of 4 (IQR 3, 6) in the 1950's to 554 (IQR 478, 583) between 2011 and 2015. The most frequently used keywords are hand disinfection, hand hygiene, hand washing, handrub, hand sanitizer and alcohol-based hand rub (ABHR). Until the 1990s, hand disinfection and hand washing were the most frequently used terms. Whilst the last decade has seen a remarkable increase in publications mentioning hand disinfection and hand hygiene and for the first time handrub, hand sanitizers and ABHR were introduced in the literature. Hand disinfection, hand hygiene and hand sanitizers are the main MeSH used by MEDLINE®. Since 2013 hand hygiene is the most frequently used MeSH and keyword. The change seen in literature in the last two decades, from hand washing and hand disinfection to hand hygiene, most probably reflect the paradigm shift favouring use of ABHR over soap and water promoted by international guidelines in the early 2000s.

  10. Healthcare professionals' hand hygiene knowledge and beliefs in the United Arab Emirates.

    PubMed

    Ng, Wai Khuan; Shaban, Ramon Z; van de Mortel, Thea

    2017-05-01

    Hand hygiene at key moments during patient care is considered an important infection prevention and control measure to reduce healthcare-associated infections. While there is extensive research in Western settings, there is little in the United Arab Emirates where particular cultural and religious customs are thought to influence hand hygiene behaviour. To examine the hand hygiene knowledge and beliefs of health professionals at a tertiary care hospital in the United Arab Emirates. A mixed methods design employed a survey followed by focus groups with nurses and doctors. A total of 109 participants (13.6%) completed the survey: 96 nurses (88%) and 13 doctors (12%). Doctors' hand hygiene knowledge was slightly higher than that of nurses (78.5% versus 73.5%). There was no significant difference in scores on the hand hygiene beliefs scale between nurses (M = 103.06; SD = 8.0) and doctors (M = 99.00; SD = 10.53; t (80) = 1.55; p = 0.13, two-tailed). Seven categories emerged following transcript analysis. Hand hygiene knowledge scores suggest further hand hygiene education is required, especially on alcohol-based hand rub use. Addressing doctors' beliefs is particularly important given the leadership roles that doctors play in healthcare settings.

  11. 30 CFR 75.1905 - Dispensing of diesel fuel.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... from other than safety cans must be dispensed by means of— (1) Gravity feed with a hose equipped with a...) An anti-siphoning device. (c) Diesel fuel must not be dispensed using compressed gas. (d) Diesel fuel...

  12. 30 CFR 75.1905 - Dispensing of diesel fuel.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... from other than safety cans must be dispensed by means of— (1) Gravity feed with a hose equipped with a...) An anti-siphoning device. (c) Diesel fuel must not be dispensed using compressed gas. (d) Diesel fuel...

  13. 30 CFR 75.1905 - Dispensing of diesel fuel.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... from other than safety cans must be dispensed by means of— (1) Gravity feed with a hose equipped with a...) An anti-siphoning device. (c) Diesel fuel must not be dispensed using compressed gas. (d) Diesel fuel...

  14. 40 CFR 165.82 - Scope of pesticide dispensing areas included.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Scope of pesticide dispensing areas...) PESTICIDE PROGRAMS PESTICIDE MANAGEMENT AND DISPOSAL Standards for Pesticide Containment Structures § 165.82 Scope of pesticide dispensing areas included. (a) What pesticide dispensing areas are subject to the...

  15. 40 CFR 165.82 - Scope of pesticide dispensing areas included.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Scope of pesticide dispensing areas...) PESTICIDE PROGRAMS PESTICIDE MANAGEMENT AND DISPOSAL Standards for Pesticide Containment Structures § 165.82 Scope of pesticide dispensing areas included. (a) What pesticide dispensing areas are subject to the...

  16. 40 CFR 165.82 - Scope of pesticide dispensing areas included.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Scope of pesticide dispensing areas...) PESTICIDE PROGRAMS PESTICIDE MANAGEMENT AND DISPOSAL Standards for Pesticide Containment Structures § 165.82 Scope of pesticide dispensing areas included. (a) What pesticide dispensing areas are subject to the...

  17. 40 CFR 165.82 - Scope of pesticide dispensing areas included.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Scope of pesticide dispensing areas...) PESTICIDE PROGRAMS PESTICIDE MANAGEMENT AND DISPOSAL Standards for Pesticide Containment Structures § 165.82 Scope of pesticide dispensing areas included. (a) What pesticide dispensing areas are subject to the...

  18. 40 CFR 165.82 - Scope of pesticide dispensing areas included.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Scope of pesticide dispensing areas...) PESTICIDE PROGRAMS PESTICIDE MANAGEMENT AND DISPOSAL Standards for Pesticide Containment Structures § 165.82 Scope of pesticide dispensing areas included. (a) What pesticide dispensing areas are subject to the...

  19. 14 CFR 23.1447 - Equipment standards for oxygen dispensing units.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Equipment standards for oxygen dispensing... Equipment Miscellaneous Equipment § 23.1447 Equipment standards for oxygen dispensing units. If oxygen... occupant for whom supplemental oxygen is to be supplied. Each dispensing unit must: (1) Provide for...

  20. 14 CFR 23.1447 - Equipment standards for oxygen dispensing units.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Equipment standards for oxygen dispensing... Equipment Miscellaneous Equipment § 23.1447 Equipment standards for oxygen dispensing units. If oxygen... occupant for whom supplemental oxygen is to be supplied. Each dispensing unit must: (1) Provide for...

  1. 14 CFR 23.1447 - Equipment standards for oxygen dispensing units.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Equipment standards for oxygen dispensing... Equipment Miscellaneous Equipment § 23.1447 Equipment standards for oxygen dispensing units. If oxygen... occupant for whom supplemental oxygen is to be supplied. Each dispensing unit must: (1) Provide for...

  2. 14 CFR 23.1447 - Equipment standards for oxygen dispensing units.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Equipment standards for oxygen dispensing... Equipment Miscellaneous Equipment § 23.1447 Equipment standards for oxygen dispensing units. If oxygen... occupant for whom supplemental oxygen is to be supplied. Each dispensing unit must: (1) Provide for...

  3. Dispensing behaviour of pharmacies in prescription drug markets.

    PubMed

    Guhl, Dennis; Stargardt, Tom; Schneider, Udo; Fischer, Katharina E

    2016-02-01

    We aim to investigate pharmacies' dispensing behaviour under the existing dispensing regulations in Germany. Using administrative data, we performed a cross-sectional retrospective study to analyse whether the competitive environment and pharmacy characteristics, i.e., organisation, lead to dispensing choices aimed at by third-party payers. We specified generalised linear models with the share of imported pharmaceuticals, generic share, and share of preferred brands as dependent variables. The final dataset contained 49,260,902 prescriptions from 16,797 pharmacies. The average share of imported pharmaceuticals across the pharmacies was 18.4% (standard deviation (SD) 8.8), the average generic share was 92.8% (SD 2.1), and compliance with preferred brands was 81.3% (SD 5.9). Pharmacies with little competition used fewer imported pharmaceuticals (p<0.001), generics (p<0.001) and preferred brands (p<0.001); less organised pharmacies yielded similar results. The difference in outcomes between pharmacies in the first and 4th quartiles of the pharmacy organisation variable is 17.4% vs. 17.0% for share of imported pharmaceuticals, 92.8% vs. 92.7% for generic share and 81.9% vs. 81.1% for compliance with preferred brands. We show that pharmacies' dispensing choices meet the aims of payers at high levels. However, dispensing behaviour varies between pharmacies. Increasing competition among pharmacies and targeting pharmacies with high shares of bill auditing seem viable options to improving dispensing behaviour as defined by payers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Dispensing medications without prescription at Saudi community pharmacy: Extent and perception

    PubMed Central

    Al-Mohamadi, A.; Badr, A.; Bin Mahfouz, L.; Samargandi, D.; Al Ahdal, A.

    2011-01-01

    Objective To investigate the dispensing behavior of pharmacists in retail pharmacy practice and to assess their attitude toward dispensing non-OTC drugs and scrutinize the causes of their malpractice; if in fact was perceived. Method Between December 2010 and January 2011 retail pharmacies in Jeddah-KSA were visited randomly by a number of voluntary collaborators who played the role of asking for one or more of the following medications without providing a prescription: Co-amoxiclav (Augmentin) or Cefaclor (Ceclor), Captopril (Capoten) and Fluoxetine (Prozac). Results A total of 60 pharmacies were randomly included in this study; 100% of the pharmacists working were male, 96.7% of them were non-Saudis and only 2 (3.3%) were Saudis. In a total of 119 drug requests, almost all pharmacists (97.9%) handed out the antibiotic immediately, 100% dispensed captopril and 89.5% gave the antipsychotic simply by following the collaborator’s request without even asking for a doctor’s prescription. In the second part of the study (where a mini-questionnaire is administered), 85% of the pharmacists agreed to answer the mini-questionnaire, and 15% refused to participate. The highest reason given for their wrongdoing, was for that if the pharmacist did not, others – of neighboring pharmacies – would do the same, followed by that there is no available OTC list. Conclusion The study confirmed that pharmacists are still violating the law, which is leading to a profound malpractice in retail pharmacies around the country. Consequently, regulations should be reviewed and structured educational campaigns are a must to both pharmacists and public. The OTC list should be generated, implemented, and monitored by Saudi regulators and penalize violators. PMID:23960815

  5. Cluster randomized trial of text message reminders to retail staff in tanzanian drug shops dispensing artemether-lumefantrine: effect on dispenser knowledge and patient adherence.

    PubMed

    Bruxvoort, Katia; Festo, Charles; Kalolella, Admirabilis; Cairns, Matthew; Lyaruu, Peter; Kenani, Mitya; Kachur, S Patrick; Goodman, Catherine; Schellenberg, David

    2014-10-01

    Artemisinin combination therapies are available in private outlets, but patient adherence might be compromised by poor advice from dispensers. In this cluster randomized trial in drug shops in Tanzania, 42 of 82 selected shops were randomized to receive text message reminders about what advice to provide when dispensing artemether-lumefantrine (AL). Eligible patients purchasing AL at shops in both arms were followed up at home and questioned about each dose taken. Dispensers were interviewed regarding knowledge of AL dispensing practices and receipt of the malaria-related text messages. We interviewed 904 patients and 110 dispensers from 77 shops. Although there was some improvement in dispenser knowledge, there was no difference between arms in adherence measured as completion of all doses (intervention 68.3%, control 69.8%, p [adjusted] = 0.6), or as completion of each dose at the correct time (intervention 33.1%, control 32.6%, p [adjusted] = 0.9). Further studies on the potential of text messages to improve adherence are needed. © The American Society of Tropical Medicine and Hygiene.

  6. 46 CFR 105.45-1 - Loading or dispensing petroleum products.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Loading or dispensing petroleum products. 105.45-1... VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Special Operating Requirements § 105.45-1 Loading or dispensing petroleum products. (a) A commercial fishing vessel must have aboard a letter of...

  7. 46 CFR 105.45-1 - Loading or dispensing petroleum products.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Loading or dispensing petroleum products. 105.45-1... VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Special Operating Requirements § 105.45-1 Loading or dispensing petroleum products. (a) A commercial fishing vessel must have aboard a letter of...

  8. 14 CFR 23.1447 - Equipment standards for oxygen dispensing units.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Equipment standards for oxygen dispensing... Equipment Miscellaneous Equipment § 23.1447 Equipment standards for oxygen dispensing units. Link to an amendment published at 76 FR 75762, December 2, 2011. If oxygen dispensing units are installed, the...

  9. Trends in radiopharmaceutical dispensing in a regional nuclear pharmacy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Basmadjian, G.P.; Johnston, J.; Barker, K.

    1982-11-01

    Dispensing trends for radiopharmaceuticals at a regional nuclear pharmacy over a 51-month period were studied. dispensing records of a regional nuclear pharmacy were analyzed with a forecasting procedure that uses univariate time data to produce time trends and autoregressive models. The overall number of prescriptions increased from 3500 to 5500 per quarter. Radiopharmaceuticals used in nuclear cardiology studies increased from less than 0.1% to 17.5% of total prescriptions dispensed, while radiopharmaceuticals used for brain imaging showed a steady decline from 29% to 11% of total prescriptions dispensed. The demand for other radiopharmaceuticals increased in areas such as renal studies, bonemore » studies, lung studies, liver-function studies, and /sup 67/Ga tumor-uptake studies, and declined slightly for static liver studies. Changes in dispensing trends for radiopharmaceuticals will continue as the practice of nuclear medicine concentrates more on functional studies and as newer imaging techniques become used for other purposes.« less

  10. Alternative Fuels Data Center: Blender Pump Dispensers

    Science.gov Websites

    ... Blender Pump Dispensers Updated April 2, 2012 Federal and local initiatives to increase the use of ethanol choose the blend of fuel they want to use based on price, their vehicle's fuel economy, and other factors blends of those two fuels. Many conventional stations today use blender pump dispensers to generate

  11. Monitoring Pharmacy Student Adherence to World Health Organization Hand Hygiene Indications Using Radio Frequency Identification

    PubMed Central

    Decker, Andrew S.; Cipriano, Gabriela C.; Tsouri, Gill

    2016-01-01

    Objective. To assess and improve student adherence to hand hygiene indications using radio frequency identification (RFID) enabled hand hygiene stations and performance report cards. Design. Students volunteered to wear RFID-enabled hospital employee nametags to monitor their adherence to hand-hygiene indications. After training in World Health Organization (WHO) hand hygiene methods and indications, student were instructed to treat the classroom as a patient care area. Report cards illustrating individual performance were distributed via e-mail to students at the middle and end of each 5-day observation period. Students were eligible for individual and team prizes consisting of Starbucks gift cards in $5 increments. Assessment. A hand hygiene station with an RFID reader and dispensing sensor recorded the nametag nearest to the station at the time of use. Mean frequency of use per student was 5.41 (range: 2-10). Distance between the student’s seat and the dispenser was the only variable significantly associated with adherence. Student satisfaction with the system was assessed by a self-administered survey at the end of the study. Most students reported that the system increased their motivation to perform hand hygiene as indicated. Conclusion. The RFID-enabled hand hygiene system and benchmarking reports with performance incentives was feasible, reliable, and affordable. Future studies should record video to monitor adherence to the WHO 8-step technique. PMID:27170822

  12. Monitoring Pharmacy Student Adherence to World Health Organization Hand Hygiene Indications Using Radio Frequency Identification.

    PubMed

    Decker, Andrew S; Cipriano, Gabriela C; Tsouri, Gill; Lavigne, Jill E

    2016-04-25

    Objective. To assess and improve student adherence to hand hygiene indications using radio frequency identification (RFID) enabled hand hygiene stations and performance report cards. Design. Students volunteered to wear RFID-enabled hospital employee nametags to monitor their adherence to hand-hygiene indications. After training in World Health Organization (WHO) hand hygiene methods and indications, student were instructed to treat the classroom as a patient care area. Report cards illustrating individual performance were distributed via e-mail to students at the middle and end of each 5-day observation period. Students were eligible for individual and team prizes consisting of Starbucks gift cards in $5 increments. Assessment. A hand hygiene station with an RFID reader and dispensing sensor recorded the nametag nearest to the station at the time of use. Mean frequency of use per student was 5.41 (range: 2-10). Distance between the student's seat and the dispenser was the only variable significantly associated with adherence. Student satisfaction with the system was assessed by a self-administered survey at the end of the study. Most students reported that the system increased their motivation to perform hand hygiene as indicated. Conclusion. The RFID-enabled hand hygiene system and benchmarking reports with performance incentives was feasible, reliable, and affordable. Future studies should record video to monitor adherence to the WHO 8-step technique.

  13. Four multifaceted countrywide campaigns to promote hand hygiene in Belgian hospitals between 2005 and 2011: impact on compliance to hand hygiene.

    PubMed

    Costers, M; Viseur, N; Catry, B; Simon, A

    2012-05-03

    Four consecutive one-month campaigns were organised to promote hand hygiene in Belgian hospitals between 2005 and 2011. The campaigns included a combination of reminders in wards, educational sessions for healthcare workers, promotion of alcohol-based hand rub use, increasing patient awareness, and audits with performance feedback. Prior and after each one month intervention period, the infection control teams measured hand hygiene compliance of healthcare workers by direct observation using a standardised observation roster. A total of 738,367 opportunities for hand hygiene were observed over the four campaigns. Compliance with hand hygiene significantly increased from 49.6% before to 68.6% after the intervention period for the first, from 53.2% to 69.5% for the second, from 58.0% to 69.1% for the third, and from 62.3% to 72.9% for the fourth campaign. The highest compliance rates were consistently observed in paediatric units. Compliance rates were always markedly lower among physicians than nurses. After patient contact and body fluid exposure risk, compliance rates were noticeably higher than before patient contact and performing aseptic procedures. We conclude that repeated countrywide campaigns to promote hand hygiene result in positive long-term outcomes. However, lower compliance rates among physicians compared with nurses, before patient contact, and before performing aseptic procedures remain challenges for future campaigns.

  14. Dispensing error rate after implementation of an automated pharmacy carousel system.

    PubMed

    Oswald, Scott; Caldwell, Richard

    2007-07-01

    A study was conducted to determine filling and dispensing error rates before and after the implementation of an automated pharmacy carousel system (APCS). The study was conducted in a 613-bed acute and tertiary care university hospital. Before the implementation of the APCS, filling and dispensing rates were recorded during October through November 2004 and January 2005. Postimplementation data were collected during May through June 2006. Errors were recorded in three areas of pharmacy operations: first-dose or missing medication fill, automated dispensing cabinet fill, and interdepartmental request fill. A filling error was defined as an error caught by a pharmacist during the verification step. A dispensing error was defined as an error caught by a pharmacist observer after verification by the pharmacist. Before implementation of the APCS, 422 first-dose or missing medication orders were observed between October 2004 and January 2005. Independent data collected in December 2005, approximately six weeks after the introduction of the APCS, found that filling and error rates had increased. The filling rate for automated dispensing cabinets was associated with the largest decrease in errors. Filling and dispensing error rates had decreased by December 2005. In terms of interdepartmental request fill, no dispensing errors were noted in 123 clinic orders dispensed before the implementation of the APCS. One dispensing error out of 85 clinic orders was identified after implementation of the APCS. The implementation of an APCS at a university hospital decreased medication filling errors related to automated cabinets only and did not affect other filling and dispensing errors.

  15. Hydrogen fuel dispensing station for transportation vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, S.P.N.; Richmond, A.A.

    1995-07-01

    A technical and economic assessment is being conducted of a hydrogen fuel dispensing station to develop an understanding of the infrastructure requirements for supplying hydrogen fuel for mobile applications. The study includes a process design of a conceptual small-scale, stand-alone, grassroots fuel dispensing facility (similar to the present-day gasoline stations) producing hydrogen by steam reforming of natural gas. Other hydrogen production processes (such as partial oxidation of hydrocarbons and water electrolysis) were reviewed to determine their suitability for manufacturing the hydrogen. The study includes an assessment of the environmental and other regulatory permitting requirements likely to be imposed on amore » hydrogen fuel dispensing station for transportation vehicles. The assessment concludes that a dispensing station designed to produce 0.75 million standard cubic feet of fuel grade (99.99%+ purity) hydrogen will meet the fuel needs of 300 light-duty vehicles per day. Preliminary economics place the total capital investment (in 1994 US dollars) for the dispensing station at $4.5 million and the annual operating costs at around $1 million. A discounted cash-flow analysis indicates that the fuel hydrogen product price (excluding taxes) to range between $1.37 to $2.31 per pound of hydrogen, depending upon the natural gas price, the plant financing scenario, and the rate of return on equity capital. A report on the assessment is due in June 1995. This paper presents a summary of the current status of the assessment.« less

  16. A general electromagnetic excitation model for electrical machines considering the magnetic saturation and rub impact

    NASA Astrophysics Data System (ADS)

    Xu, Xueping; Han, Qinkai; Chu, Fulei

    2018-03-01

    The electromagnetic vibration of electrical machines with an eccentric rotor has been extensively investigated. However, magnetic saturation was often neglected. Moreover, the rub impact between the rotor and stator is inevitable when the amplitude of the rotor vibration exceeds the air-gap. This paper aims to propose a general electromagnetic excitation model for electrical machines. First, a general model which takes the magnetic saturation and rub impact into consideration is proposed and validated by the finite element method and reference. The dynamic equations of a Jeffcott rotor system with electromagnetic excitation and mass imbalance are presented. Then, the effects of pole-pair number and rubbing parameters on vibration amplitude are studied and approaches restraining the amplitude are put forward. Finally, the influences of mass eccentricity, resultant magnetomotive force (MMF), stiffness coefficient, damping coefficient, contact stiffness and friction coefficient on the stability of the rotor system are investigated through the Floquet theory, respectively. The amplitude jumping phenomenon is observed in a synchronous generator for different pole-pair numbers. The changes of design parameters can alter the stability states of the rotor system and the range of parameter values forms the zone of stability, which lays helpful suggestions for the design and application of the electrical machines.

  17. Hand rub dose needed for a single disinfection varies according to product: a bias in benchmarking using indirect hand hygiene indicator.

    PubMed

    Girard, Raphaële; Aupee, Martine; Erb, Martine; Bettinger, Anne; Jouve, Alice

    2012-12-01

    The 3ml volume currently used as the hand hygiene (HH) measure has been explored as the pertinent dose for an indirect indicator of HH compliance. A multicenter study was conducted in order to ascertain the required dose using different products. The average contact duration before drying was measured and compared with references. Effective hand coverage had to include the whole hand and the wrist. Two durations were chosen as points of reference: 30s, as given by guidelines, and the duration validated by the European standard EN 1500. Each product was to be tested, using standardized procedures, by three nosocomial infection prevention teams, for three different doses (3, 2 and 1.5ml). Data from 27 products and 1706 tests were analyzed. Depending on the product, the dose needed to ensure a 30-s contact duration in 75% of tests ranging from 2ml to more than 3ml, and to ensure a contact duration exceeding the EN 1500 times in 75% of tests ranging from 1.5ml to more than 3ml. The aftermath interpretation is the following: if different products are used, the volume utilized does not give an unbiased estimation of the HH compliance. Other compliance evaluation methods remain necessary for efficient benchmarking. Copyright © 2012 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.

  18. Alternative Fuels Data Center: Status Update: E85 Dispenser System

    Science.gov Websites

    Alternative Fuels Data Center: Status Update: E85 Dispenser System Certified (June 2010) on Facebook Tweet about Alternative Fuels Data Center: Status Update: E85 Dispenser System Certified (June 2010) on Twitter Bookmark Alternative Fuels Data Center: Status Update: E85 Dispenser System Certified (June 2010

  19. 14 CFR 25.1447 - Equipment standards for oxygen dispensing units.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Equipment standards for oxygen dispensing... § 25.1447 Equipment standards for oxygen dispensing units. If oxygen dispensing units are installed... supplemental oxygen is to be supplied. Units must be designed to cover the nose and mouth and must be equipped...

  20. 14 CFR 25.1447 - Equipment standards for oxygen dispensing units.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Equipment standards for oxygen dispensing... § 25.1447 Equipment standards for oxygen dispensing units. If oxygen dispensing units are installed... supplemental oxygen is to be supplied. Units must be designed to cover the nose and mouth and must be equipped...

  1. 14 CFR 25.1447 - Equipment standards for oxygen dispensing units.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Equipment standards for oxygen dispensing... § 25.1447 Equipment standards for oxygen dispensing units. If oxygen dispensing units are installed... supplemental oxygen is to be supplied. Units must be designed to cover the nose and mouth and must be equipped...

  2. 14 CFR 25.1447 - Equipment standards for oxygen dispensing units.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Equipment standards for oxygen dispensing... § 25.1447 Equipment standards for oxygen dispensing units. If oxygen dispensing units are installed... supplemental oxygen is to be supplied. Units must be designed to cover the nose and mouth and must be equipped...

  3. 14 CFR 25.1447 - Equipment standards for oxygen dispensing units.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Equipment standards for oxygen dispensing... § 25.1447 Equipment standards for oxygen dispensing units. If oxygen dispensing units are installed... supplemental oxygen is to be supplied. Units must be designed to cover the nose and mouth and must be equipped...

  4. Process For Patterning Dispenser-Cathode Surfaces

    NASA Technical Reports Server (NTRS)

    Garner, Charles E.; Deininger, William D.

    1989-01-01

    Several microfabrication techniques combined into process cutting slots 100 micrometer long and 1 to 5 micrometer wide into tungsten dispenser cathodes for traveling-wave tubes. Patterned photoresist serves as mask for etching underlying aluminum. Chemically-assisted ion-beam etching with chlorine removes exposed parts of aluminum layer. Etching with fluorine or chlorine trifluoride removes tungsten not masked by aluminum layer. Slots enable more-uniform low-work function coating dispensed to electron-emitting surface. Emission of electrons therefore becomes more uniform over cathode surface.

  5. The K-1 Active Dispenser for Orbit Transfer

    NASA Astrophysics Data System (ADS)

    Lai, G.; Cochran, D.; Curtis, R.

    2002-01-01

    Kistler Aerospace Corporation is building the K-1, the world's first fully reusable launch vehicle. The two-stage K- 1 is designed primarily to service the market for low-earth orbit (LEO) missions, due to Kistler's need to recover both stages. For customers requiring payload delivery to high-energy orbits, Kistler can outfit the payload with a K- 1 Active Dispenser (an expendable third stage). The K-1 second stage will deploy the Active Dispenser mated with its payload into a 200 km circular LEO parking orbit. From this orbit, the Active Dispenser would use its own propulsion to place its payload into the final desired drop-off orbit or earth-escape trajectory. This approach allows Kistler to combine the low-cost launch services offered by the reusable two-stage K-1 with the versatility of a restartable, expendable upper stage. Enhanced with an Active Dispenser, the K-1 will be capable of delivering 1,500 kg to a geosynchronous transfer orbit or up to approximately 1,000 kg into a Mars rendezvous trajectory. The list price of a K-1 Active Dispenser launch is 25 million (plus the price of mission unique integration services) significantly less than the price of any launch vehicle service in the world with comparable capability.

  6. The impact of automation on workload and dispensing errors in a hospital pharmacy.

    PubMed

    James, K Lynette; Barlow, Dave; Bithell, Anne; Hiom, Sarah; Lord, Sue; Pollard, Mike; Roberts, Dave; Way, Cheryl; Whittlesea, Cate

    2013-04-01

    To determine the effect of installing an original-pack automated dispensing system (ADS) on dispensary workload and prevented dispensing incidents in a hospital pharmacy. Data on dispensary workload and prevented dispensing incidents, defined as dispensing errors detected and reported before medication had left the pharmacy, were collected over 6 weeks at a National Health Service hospital in Wales before and after the installation of an ADS. Workload was measured by non-participant observation using the event recording technique. Prevented dispensing incidents were self-reported by pharmacy staff on standardised forms. Median workloads (measured as items dispensed/person/hour) were compared using Mann-Whitney U tests and rate of prevented dispensing incidents were compared using Chi-square test. Spearman's rank correlation was used to examine the association between workload and prevented dispensing incidents. A P value of ≤0.05 was considered statistically significant. Median dispensary workload was significantly lower pre-automation (9.20 items/person/h) compared to post-automation (13.17 items/person/h, P < 0.001). Rate of prevented dispensing incidents was significantly lower post-automation (0.28%) than pre-automation (0.64%, P < 0.0001) but there was no difference (P = 0.277) between the types of dispensing incidents. A positive association existed between workload and prevented dispensing incidents both pre- (ρ = 0.13, P = 0.015) and post-automation (ρ = 0.23, P < 0.001). Dispensing incidents were found to occur during prolonged periods of moderate workload or after a busy period. Study findings suggest that automation improves dispensing efficiency and reduces the rate of prevented dispensing incidents. It is proposed that prevented dispensing incidents frequently occurred during periods of high workload due to involuntary automaticity. Prevented dispensing incidents occurring after a busy period were attributed to staff

  7. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    NASA Astrophysics Data System (ADS)

    de Vos, Marc; Torah, Russel; Tudor, John

    2016-04-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps.

  8. Construction of a smart medication dispenser with high degree of scalability and remote manageability.

    PubMed

    Pak, JuGeon; Park, KeeHyun

    2012-01-01

    We propose a smart medication dispenser having a high degree of scalability and remote manageability. We construct the dispenser to have extensible hardware architecture for achieving scalability, and we install an agent program in it for achieving remote manageability. The dispenser operates as follows: when the real-time clock reaches the predetermined medication time and the user presses the dispense button at that time, the predetermined medication is dispensed from the medication dispensing tray (MDT). In the proposed dispenser, the medication for each patient is stored in an MDT. One smart medication dispenser contains mainly one MDT; however, the dispenser can be extended to include more MDTs in order to support multiple users using one dispenser. For remote management, the proposed dispenser transmits the medication status and the system configurations to the monitoring server. In the case of a specific event such as a shortage of medication, memory overload, software error, or non-adherence, the event is transmitted immediately. All these operations are performed automatically without the intervention of patients, through the agent program installed in the dispenser. Results of implementation and verification show that the proposed dispenser operates normally and performs the management operations from the medication monitoring server suitably.

  9. A Reality Rub Crisis Intervention: "I Wish There Was a Law against Belts."

    ERIC Educational Resources Information Center

    Long, Nicholas J.; Techet, Bonnie

    1994-01-01

    Presents Life Space Interview (LSI) or Life Space Crisis Intervention (LSCI) with second-grade student from threatening home environment. Uses Reality Rub Intervention Interview, focusing on five variations: distorted perceptions, tunnel vision, faulty thinking, avoidance, and alibi. Describes incident that led to intervention, interview itself,…

  10. B11 NMR in the layered diborides OsB2 and RuB2

    NASA Astrophysics Data System (ADS)

    Suh, B. J.; Zong, X.; Singh, Y.; Niazi, A.; Johnston, D. C.

    2007-10-01

    B11 nuclear magnetic resonance (NMR) measurements have been performed on B11 enriched OsB2 and RuB2 polycrystalline powder samples in an external field of 4.7T and in the temperature range, 4.2KRuB2 , respectively. The experimental results indicate that a p character dominates the conduction electron wave function at the B site with a negligibly small s character in both compounds.

  11. 46 CFR 105.05-1 - Commercial fishing vessels dispensing petroleum products.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Commercial fishing vessels dispensing petroleum products... MISCELLANEOUS VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Application § 105.05-1 Commercial fishing vessels dispensing petroleum products. (a) The provisions of this part, with the exception of...

  12. 46 CFR 105.05-1 - Commercial fishing vessels dispensing petroleum products.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Commercial fishing vessels dispensing petroleum products... MISCELLANEOUS VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Application § 105.05-1 Commercial fishing vessels dispensing petroleum products. (a) The provisions of this part, with the exception of...

  13. 46 CFR 105.05-1 - Commercial fishing vessels dispensing petroleum products.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Commercial fishing vessels dispensing petroleum products... MISCELLANEOUS VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Application § 105.05-1 Commercial fishing vessels dispensing petroleum products. (a) The provisions of this part, with the exception of...

  14. 21 CFR 209.11 - Dispensing and distributing the side effects statement.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... SERVICES (CONTINUED) DRUGS: GENERAL REQUIREMENT FOR AUTHORIZED DISPENSERS AND PHARMACIES TO DISTRIBUTE A...) Each authorized dispenser or pharmacy must distribute the side effects statement with each prescription... distributed with new and refill prescriptions. (b) An authorized dispenser or pharmacy must choose one or more...

  15. 21 CFR 209.11 - Dispensing and distributing the side effects statement.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... SERVICES (CONTINUED) DRUGS: GENERAL REQUIREMENT FOR AUTHORIZED DISPENSERS AND PHARMACIES TO DISTRIBUTE A...) Each authorized dispenser or pharmacy must distribute the side effects statement with each prescription... distributed with new and refill prescriptions. (b) An authorized dispenser or pharmacy must choose one or more...

  16. 21 CFR 209.11 - Dispensing and distributing the side effects statement.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... SERVICES (CONTINUED) DRUGS: GENERAL REQUIREMENT FOR AUTHORIZED DISPENSERS AND PHARMACIES TO DISTRIBUTE A...) Each authorized dispenser or pharmacy must distribute the side effects statement with each prescription... distributed with new and refill prescriptions. (b) An authorized dispenser or pharmacy must choose one or more...

  17. 21 CFR 209.11 - Dispensing and distributing the side effects statement.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... SERVICES (CONTINUED) DRUGS: GENERAL REQUIREMENT FOR AUTHORIZED DISPENSERS AND PHARMACIES TO DISTRIBUTE A...) Each authorized dispenser or pharmacy must distribute the side effects statement with each prescription... distributed with new and refill prescriptions. (b) An authorized dispenser or pharmacy must choose one or more...

  18. 21 CFR 209.11 - Dispensing and distributing the side effects statement.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... SERVICES (CONTINUED) DRUGS: GENERAL REQUIREMENT FOR AUTHORIZED DISPENSERS AND PHARMACIES TO DISTRIBUTE A...) Each authorized dispenser or pharmacy must distribute the side effects statement with each prescription... distributed with new and refill prescriptions. (b) An authorized dispenser or pharmacy must choose one or more...

  19. Recent advances in inkjet dispensing technologies: applications in drug discovery.

    PubMed

    Zhu, Xiangcheng; Zheng, Qiang; Yang, Hu; Cai, Jin; Huang, Lei; Duan, Yanwen; Xu, Zhinan; Cen, Peilin

    2012-09-01

    Inkjet dispensing technology is a promising fabrication methodology widely applied in drug discovery. The automated programmable characteristics and high-throughput efficiency makes this approach potentially very useful in miniaturizing the design patterns for assays and drug screening. Various custom-made inkjet dispensing systems as well as specialized bio-ink and substrates have been developed and applied to fulfill the increasing demands of basic drug discovery studies. The incorporation of other modern technologies has further exploited the potential of inkjet dispensing technology in drug discovery and development. This paper reviews and discusses the recent developments and practical applications of inkjet dispensing technology in several areas of drug discovery and development including fundamental assays of cells and proteins, microarrays, biosensors, tissue engineering, basic biological and pharmaceutical studies. Progression in a number of areas of research including biomaterials, inkjet mechanical systems and modern analytical techniques as well as the exploration and accumulation of profound biological knowledge has enabled different inkjet dispensing technologies to be developed and adapted for high-throughput pattern fabrication and miniaturization. This in turn presents a great opportunity to propel inkjet dispensing technology into drug discovery.

  20. 30 CFR 75.1905 - Dispensing of diesel fuel.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Dispensing of diesel fuel. 75.1905 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1905 Dispensing of diesel fuel. (a) Diesel-powered equipment in underground coal mines may be refueled only from safety cans...

  1. 30 CFR 75.1905 - Dispensing of diesel fuel.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Dispensing of diesel fuel. 75.1905 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1905 Dispensing of diesel fuel. (a) Diesel-powered equipment in underground coal mines may be refueled only from safety cans...

  2. Healthcare professionals’ hand hygiene knowledge and beliefs in the United Arab Emirates

    PubMed Central

    Ng, Wai Khuan; Shaban, Ramon Z.; van de Mortel, Thea

    2016-01-01

    Background: Hand hygiene at key moments during patient care is considered an important infection prevention and control measure to reduce healthcare-associated infections. While there is extensive research in Western settings, there is little in the United Arab Emirates where particular cultural and religious customs are thought to influence hand hygiene behaviour. Aim: To examine the hand hygiene knowledge and beliefs of health professionals at a tertiary care hospital in the United Arab Emirates. Methods: A mixed methods design employed a survey followed by focus groups with nurses and doctors. Findings: A total of 109 participants (13.6%) completed the survey: 96 nurses (88%) and 13 doctors (12%). Doctors’ hand hygiene knowledge was slightly higher than that of nurses (78.5% versus 73.5%). There was no significant difference in scores on the hand hygiene beliefs scale between nurses (M = 103.06; SD = 8.0) and doctors (M = 99.00; SD = 10.53; t (80) = 1.55; p = 0.13, two-tailed). Seven categories emerged following transcript analysis. Discussion: Hand hygiene knowledge scores suggest further hand hygiene education is required, especially on alcohol-based hand rub use. Addressing doctors’ beliefs is particularly important given the leadership roles that doctors play in healthcare settings. PMID:28989517

  3. Non-prescription sale and dispensing of antibiotics in community pharmacies in Zambia.

    PubMed

    Kalungia, Aubrey Chichonyi; Burger, Johanita; Godman, Brian; Costa, Juliana de Oliveira; Simuwelu, Chimwemwe

    2016-12-01

    In Zambia, antibiotics are categorized as prescription-only medicines. Antibiotics dispensed without a prescription pose a public health threat, which is a concern. Consequently, the aim is to ascertain the extent of non-prescription sales and dispensing of antibiotics in community pharmacies in Zambia. The practice of non-prescription sale and dispensing were assessed in 73 randomly selected community retail pharmacies, using a structured interviewer-administered questionnaire with simulated case scenarios. Majority (97%) stated that clients frequently requested non-prescribed antibiotics. Interviewees usually asked clients' indications (94%), counselled on dosing (96%) and suggested changes to antibiotic choices (97%). All (100%) dispensed non-prescribed antibiotics. Commonly dispensed antibiotics included amoxicillin (52%), cotrimoxazole (25%) and metronidazole (23%). Non-prescription sale and dispensing of antibiotics was significantly associated with interviewees' professional qualification in four out of five simulations. Non-prescription sale and dispensing of antibiotics is widespread in Zambia. Concerted public and professional interventions are needed coupled with stronger regulatory enforcement to reduce this.

  4. Focused ion beam-assisted technology in sub-picolitre micro-dispenser fabrication

    NASA Astrophysics Data System (ADS)

    Lopez, M. J.; Caballero, D.; Campo, E. M.; Perez-Castillejos, R.; Errachid, A.; Esteve, J.; Plaza, J. A.

    2008-07-01

    Novel medical and biological applications are driving increased interest in the fabrication of micropipette or micro-dispensers. Reduced volume samples and drug dosages are prime motivators in this effort. We have combined microfabrication technology with ion beam milling techniques to successfully produce cantilever-type polysilicon micro-dispensers with 3D enclosed microchannels. The microfabrication technology described here allows for the designing of nozzles with multiple shapes. The contribution of ion beam milling has had a large impact on the fabrication process and on further customizing shapes of nozzles and inlet ports. Functionalization tests were conducted to prove the viability of ion beam-fabricated micro-dispensers. Self-assembled monolayers were successfully formed when a gold surface was patterned with a thiol solution dispensed by the fabricated micro-dispensers.

  5. Drug dispensing practices at pharmacies in Bengaluru: A cross-sectional study

    PubMed Central

    Soumya, R.; Devarashetty, Vijayalakshmi; Jayanthi, C. R.; Sushma, M.

    2016-01-01

    Objectives: Pharmacists are one of the crucial focal points for health care in the community. They have tremendous outreach to the public as pharmacies are often the first-port-of-call. With the increase of ready-to-use drugs, the main health-related activity of a pharmacist today is to assure the quality of dispensing, a key element to promote rational medicine use. Materials and Methods: A cross-sectional study of 200 pharmacies, 100 each in various residential (R) and commercial (C) areas of Bengaluru, was conducted using a prevalidated questionnaire administered to the chief pharmacist or the person-in-charge by the investigators. Results: Dispensing without prescription at pharmacies was 45% of the total dispensing encounters and significantly higher (χ2 = 15.2, P < 0.001, df = 1) in pharmacies of residential areas (46.64%) as compared to commercial areas (43.64%). Analgesics were the most commonly dispensed drugs (90%) without prescription. Only 31% insisted on dispensing full course of antibiotics prescribed and 19% checked for completeness of prescription before dispensing. Although 97% of the pharmacies had a refrigerator, 31% of these did not have power back-up. Only about 50% of the pharmacists were aware of Schedule H. Conclusion: This study shows a high proportion of dispensing encounters without prescription, a higher rate of older prescription refills, many irregularities in medication counseling and unsatisfactory storage practices. It also revealed that about half of the pharmacists were unaware of Schedule H and majority of them about current regulations. Hence, regulatory enforcement and educational campaigns are a prerequisite to improve dispenser's knowledge and dispensing practices. PMID:27756944

  6. Slow Release of Plant Volatiles Using Sol-Gel Dispensers.

    PubMed

    Bian, L; Sun, X L; Cai, X M; Chen, Z M

    2014-12-01

    The black citrus aphid, also known as the tea aphid, (Toxoptera aurantii Boyer) attacks economically important crops, including tea (Camellia sinensis (L.) O. Kuntze). In the current study, silica sol-gel formulations were screened to find one that could carry and release C. sinensis plant volatiles to lure black citrus aphids in a greenhouse. The common plant volatile trans-2-hexen-1-al was used as a model molecule to screen for suitable sol-gel formulations. A zNose (Electronic Sensor Technology, Newbury Park, CA) transportable gas chromatograph was used to continuously monitor the volatile emissions. A sol-gel formulation containing tetramethyl orthosilicate and methyltrimethoxysilane in an 8:2 (vol:vol) ratio was selected to develop a slow-release dispenser. The half-life of trans-2-hexen-1-al in the sol-gel dispenser increased slightly with the volume of this compound in the dispenser. Ten different volatiles were tested in the sol-gel dispenser. Alcohols of 6-10 carbons had the longest half-lives (3.01-3.77 d), while esters of 6-12 carbons had the shortest (1.53-2.28 d). Release of these volatiles from the dispensers could not be detected by the zNose after 16 d (cis-3-hexenyl acetate) to 26 d (3,7-dimethylocta-1,6-dien-3-ol). In greenhouse experiments, trans-2-hexen-1-al and cis-3-hexen-1-ol released from the sol-gel dispensers attracted aphids for ≍17 d, and release of these volatiles could not be detected by the zNose after ≍24 d. The sol-gel dispensers performed adequately for the slow release of plant volatiles to trap aphids in the greenhouse. © 2014 Entomological Society of America.

  7. Hand washing with soap and water together with behavioural recommendations prevents infections in common work environment: an open cluster-randomized trial.

    PubMed

    Savolainen-Kopra, Carita; Haapakoski, Jaason; Peltola, Piia A; Ziegler, Thedi; Korpela, Terttu; Anttila, Pirjo; Amiryousefi, Ali; Huovinen, Pentti; Huvinen, Markku; Noronen, Heikki; Riikkala, Pia; Roivainen, Merja; Ruutu, Petri; Teirilä, Juha; Vartiainen, Erkki; Hovi, Tapani

    2012-01-16

    Hand hygiene is considered as an important means of infection control. We explored whether guided hand hygiene together with transmission-limiting behaviour reduces infection episodes and lost days of work in a common work environment in an open cluster-randomized 3-arm intervention trial. A total of 21 clusters (683 persons) were randomized to implement hand hygiene with soap and water (257 persons), with alcohol-based hand rub (202 persons), or to serve as a control (224 persons). Participants in both intervention arms also received standardized instructions on how to limit the transmission of infections. The intervention period (16 months) included the emergence of the 2009 influenza pandemic and the subsequent national hand hygiene campaign influencing also the control arm. In the total follow-up period there was a 6.7% reduction of infection episodes in the soap-and water arm (p = 0.04). Before the onset of the anti-pandemic campaign, a statistically significant (p = 0.002) difference in the mean occurrence of infection episodes was observed between the control (6.0 per year) and the soap-and-water arm (5.0 per year) but not between the control and the alcohol-rub arm (5.6 per year). Neither intervention had a decreasing effect on absence from work. We conclude that intensified hand hygiene using water and soap together with behavioural recommendations can reduce the occurrence of self-reported acute illnesses in common work environment. Surprisingly, the occurrence of reported sick leaves also increased in the soap-and water-arm. ClinicalTrials.gov: NCT00981877 The Finnish Work Environment Fund and the National Institute for Health and Welfare.

  8. Effects of dispense equipment sequence on process start-up defects

    NASA Astrophysics Data System (ADS)

    Brakensiek, Nick; Sevegney, Michael

    2013-03-01

    Photofluid dispense systems within coater/developer tools have been designed with the intent to minimize cost of ownership to the end user. Waste and defect minimization, dispense quality and repeatability, and ease of use are all desired characteristics. One notable change within commercially available systems is the sequence in which process fluid encounters dispense pump and filtration elements. Traditionally, systems adopted a pump-first sequence, where fluid is "pushed through" a point-of-use filter just prior to dispensing on the wafer. Recently, systems configured in a pump-last scheme have become available, where fluid is "pulled through" the filter, into the pump, and then is subsequently dispensed. The present work constitutes a comparative evaluation of the two equipment sequences with regard to the aforementioned characteristics that impact cost of ownership. Additionally, removal rating and surface chemistry (i.e., hydrophilicity) of the point-of-use filter are varied in order to evaluate their influence on system start-up and defects.

  9. Methods and systems for integrating fluid dispensing technology with stereolithography

    DOEpatents

    Medina, Francisco; Wicker, Ryan; Palmer, Jeremy A.; Davis, Don W.; Chavez, Bart D.; Gallegos, Phillip L.

    2010-02-09

    An integrated system and method of integrating fluid dispensing technologies (e.g., direct-write (DW)) with rapid prototyping (RP) technologies (e.g., stereolithography (SL)) without part registration comprising: an SL apparatus and a fluid dispensing apparatus further comprising a translation mechanism adapted to translate the fluid dispensing apparatus along the Z-, Y- and Z-axes. The fluid dispensing apparatus comprises: a pressurized fluid container; a valve mechanism adapted to control the flow of fluid from the pressurized fluid container; and a dispensing nozzle adapted to deposit the fluid in a desired location. To aid in calibration, the integrated system includes a laser sensor and a mechanical switch. The method further comprises building a second part layer on top of the fluid deposits and optionally accommodating multi-layered circuitry by incorporating a connector trace. Thus, the present invention is capable of efficiently building single and multi-material SL fabricated parts embedded with complex three-dimensional circuitry using DW.

  10. Hand contamination during routine care in medical wards: the role of hand hygiene compliance.

    PubMed

    Monistrol, Olga; López, M Liboria; Riera, Montserrat; Font, Roser; Nicolás, Carme; Escobar, Miguel Angel; Freixas, Núria; Garau, Javier; Calbo, Esther

    2013-04-01

    The hands of healthcare workers (HCWs) are the most common vehicle for the transmission of micro-organisms from patient to patient and within the healthcare environment. The aim of this study was to evaluate the impact of a multimodal campaign on the type and amount of resident and transient flora and the presence of potential risk factors for hand contamination during routine care. A before-after (PRE and POST periods) interventional study was carried out in medical wards of a tertiary care hospital. Eighty-nine samples were analysed. Samples were cultured immediately before patient contact using a glove-juice method. Data collected included socio-demographic and risk factors for hand contamination. Flora was measured as log10 c.f.u. ml(-1) and evaluated by comparing median values in the PRE and POST periods. Transient flora was isolated from the hands of 67.4 and 46.1 % of HCWs in the PRE and POST periods, respectively (P<0.001). Enterobacteriaceae, Pseudomonas spp. and meticillin-sensitive Staphylococcus aureus were the predominant contaminants. Resident flora was isolated from 92.1 % of HCWs in the PRE period and from 70.8 % in the POST period (P<0.001). The meticillin-resistant coagulase-negative staphylococci log10 c.f.u. count ml(-1) decreased from 1.96 ± 1.2 to 0.89 ± 1.2 (mean ± s d; P<0.001), and the global flora count decreased from 2.77 ± 1.1 to 1.56 ± 1.4 (P<0.001). In the POST period, the wearing of fewer rings (P<0.001), shorter fingernail length (P = 0.008), a shorter time since recent hand hygiene (HH) (P = 0.007) and an increased use of alcohol-based hand rub instead of soap (P<0.001) were documented. The HH multimodal strategy reduced the number of risk factors and the level of HCW hand contamination.

  11. Alternative Fuels Data Center: Underwriters Laboratories Ethanol Dispenser

    Science.gov Websites

    alternate equivalent dispenser design to be submitted for approval. Each jurisdiction has its own process grant a waiver or variance on a case-by-case basis for alternative equivalent dispensers for mid- to procedures used to evaluate the product. The group of manufacturers and industry partners interested in

  12. 76 FR 27352 - Agency Information Collection Activities: Proposed Collection; Comments Requested: Dispensing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-11

    ... Collection Activities: Proposed Collection; Comments Requested: Dispensing Records of Individual.../Collection: Dispensing records of individual practitioners. (3) Agency form number, if any, and the... requires that individual practitioners keep records of the dispensing and administration of controlled...

  13. Outbreaks where food workers have been implicated in the spread of foodborne disease. Part 10. Alcohol-based antiseptics for hand disinfection and a comparison of their effectiveness with soaps.

    PubMed

    Todd, Ewen C D; Michaels, Barry S; Holah, John; Smith, Debra; Greig, Judy D; Bartleson, Charles A

    2010-11-01

    Alcohol compounds are increasingly used as a substitute for hand washing in health care environments and some public places because these compounds are easy to use and do not require water or hand drying materials. However, the effectiveness of these compounds depends on how much soil (bioburden) is present on the hands. Workers in health care environments and other public places must wash their hands before using antiseptics and/or wearing gloves. However, alcohol-based antiseptics, also called rubs and sanitizers, can be very effective for rapidly destroying some pathogens by the action of the aqueous alcohol solution without the need for water or drying with towels. Alcohol-based compounds seem to be the most effective treatment against gram-negative bacteria on lightly soiled hands, but antimicrobial soaps are as good or better when hands are more heavily contaminated. Instant sanitizers have no residual effect, unlike some antimicrobial soaps that retain antimicrobial activity after the hygienic action has been completed, e.g., after hand washing. Many alcohol-based hand rubs have antimicrobial agents added to them, but each formulation must be evaluated against the target pathogens in the environment of concern before being considered for use. Wipes also are widely used for quick cleanups of hands, other body parts, and surfaces. These wipes often contain alcohol and/or antimicrobial compounds and are used for personal hygiene where water is limited. However, antiseptics and wipes are not panaceas for every situation and are less effective in the presence of more than a light soil load and against most enteric viruses.

  14. Quality improvement program for the B83 bomb hand truck

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loll, M.B.; Buck, S.A.

    1998-04-01

    This report describes the problems, issues, and history of the H1347 bomb hand truck for the B83 bomb after the bomb was put into stockpile in the mid-1980s. Major issues that were reported in Unsatisfactory Reports (URs) were cracking problems on stacking fixture welds, cracked welds on the caster bracket receptacles on the cradle, cracked caster mounting brackets, casters unlocking from the swivel lock position, and caster tires rubbing and binding on the stacking frame. Resolution of these and other problems is described. The introduction of the H695B storage-only bomb hand truck to alleviate a shortage of bomb hand trucksmore » in the mid-1990s is described. The development and qualification of the H1347A bomb hand truck as a replacement for the H695 B is covered. The results from load test evaluations on the stacking fixture, cradle, and casters for the H1347 are described along with towing results on one and two-high stack configurations of B83 bombs in bomb hand trucks. New towing and truck/trailer transport procedures are described. Development, evaluation, and production recommendations for a stronger caster mounting bracket are described.« less

  15. Method and apparatus for producing drops using a drop-on-demand dispenser

    DOEpatents

    Chen, Alvin U.; Basaran, Osman A.

    2003-01-01

    A method and apparatus for dispensing fluid from a drop-on-demand (DOD) fluid dispenser. The method involves withdrawing fluid in the dispenser for a first duration of time, followed by a second duration of time during which the fluid is propelled toward the orifice of the dispenser. Following the period during which the fluid is propelled, there is a second withdrawing of the fluid into the dispenser. The duration of the propelling period is shorter than the duration of either the first withdrawing or the second withdrawing. The propelling of the fluid results in the extension of a small tongue of fluid from the meniscus of the fluid. The second withdrawing of the fluid results in a retraction of the meniscus into the passageway such that only the small tongue of fluid separates and is ejected from the dispenser.

  16. A comparison of automated dispensing cabinet optimization methods.

    PubMed

    O'Neil, Daniel P; Miller, Adam; Cronin, Daniel; Hatfield, Chad J

    2016-07-01

    Results of a study comparing two methods of optimizing automated dispensing cabinets (ADCs) are reported. Eight nonprofiled ADCs were optimized over six months. Optimization of each cabinet involved three steps: (1) removal of medications that had not been dispensed for at least 180 days, (2) movement of ADC stock to better suit end-user needs and available space, and (3) adjustment of par levels (desired on-hand inventory levels). The par levels of four ADCs (the Day Supply group) were adjusted according to average daily usage; the par levels of the other four ADCs (the Formula group) were adjusted using a standard inventory formula. The primary outcome was the vend:fill ratio, while secondary outcomes included total inventory, inventory cost, quantity of expired medications, and ADC stockout percentage. The total number of medications stocked in the eight machines was reduced from 1,273 in a designated two-month preoptimization period to 1,182 in a designated two-month postoptimization period, yielding a carrying cost savings of $44,981. The mean vend:fill ratios before and after optimization were 4.43 and 4.46, respectively. The vend:fill ratio for ADCs in the Formula group increased from 4.33 before optimization to 5.2 after optimization; in the Day Supply group, the ratio declined (from 4.52 to 3.90). The postoptimization interaction difference between the Formula and Day Supply groups was found to be significant (p = 0.0477). ADC optimization via a standard inventory formula had a positive impact on inventory costs, refills, vend:fill ratios, and stockout percentages. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  17. Volumetric dispenser for small particles from plural sources

    DOEpatents

    Bradley, R.A.; Miller, W.H.; Sease, J.D.

    1975-12-16

    Apparatus is described for rapidly and accurately dispensing measured volumes of small particles from a supply hopper. The apparatus includes an adjustable, vertically oriented measuring tube and orifice member defining the volume to be dispensed, a ball plug valve for selectively closing the bottom end of the orifice member, and a compression valve for selectively closing the top end of the measuring tube. A supply hopper is disposed above and in gravity flow communication with the measuring tube. Properly sequenced opening and closing of the two valves provides accurate volumetric discharge through the ball plug valve. A dispensing system is described wherein several appropriately sized measuring tubes, orifice members, and associated valves are arranged to operate contemporaneously to facilitate blending of different particles.

  18. Concomitant prescribing and dispensing errors at a Brazilian hospital: a descriptive study

    PubMed Central

    Silva, Maria das Dores Graciano; Rosa, Mário Borges; Franklin, Bryony Dean; Reis, Adriano Max Moreira; Anchieta, Lêni Márcia; Mota, Joaquim Antônio César

    2011-01-01

    OBJECTIVE: To analyze the prevalence and types of prescribing and dispensing errors occurring with high-alert medications and to propose preventive measures to avoid errors with these medications. INTRODUCTION: The prevalence of adverse events in health care has increased, and medication errors are probably the most common cause of these events. Pediatric patients are known to be a high-risk group and are an important target in medication error prevention. METHODS: Observers collected data on prescribing and dispensing errors occurring with high-alert medications for pediatric inpatients in a university hospital. In addition to classifying the types of error that occurred, we identified cases of concomitant prescribing and dispensing errors. RESULTS: One or more prescribing errors, totaling 1,632 errors, were found in 632 (89.6%) of the 705 high-alert medications that were prescribed and dispensed. We also identified at least one dispensing error in each high-alert medication dispensed, totaling 1,707 errors. Among these dispensing errors, 723 (42.4%) content errors occurred concomitantly with the prescribing errors. A subset of dispensing errors may have occurred because of poor prescription quality. The observed concomitancy should be examined carefully because improvements in the prescribing process could potentially prevent these problems. CONCLUSION: The system of drug prescribing and dispensing at the hospital investigated in this study should be improved by incorporating the best practices of medication safety and preventing medication errors. High-alert medications may be used as triggers for improving the safety of the drug-utilization system. PMID:22012039

  19. Numerical results of the influence of thermal effects on the turbo machine rotordynamics induced by light-rubs against a brush seal

    NASA Astrophysics Data System (ADS)

    Fay, R.; Kreuzer, D.; Liebich, R.; Wiedemann, T.; Werner, S.

    2018-07-01

    Brush seals are an efficient alternative for labyrinth seals in turbomachinery. Brush seals show on the one hand a better leakage reduction in relation to their axial length and hence allow a shorter design of the machinery. On the other hand, the particularly small gap between bristles and the engine shaft increases the risk of rotor-stator-contact. The flexible brush seals induces basically light-rubs that in some cases might lead to spiral vibrations and thermal mechanical instabilities. Spiral vibrations are caused by a thermal deflection of the rotor induced by a heat flow into the shaft. To predict areas of instabilites during the design process a tool was developed at the Berlin Institute of Technology. The model combines a rotor dynamic model and a thermal model. The thermal system is reduced using a stationary solution, so that the final system, on which the stability analysis is performed, is comparable to the established Kellenberger model. The paper presents the numerical model for the predictions of unstable regions depending on rotational speed. This is illustrated by means of an example of an axial compressor manufactured by MAN Diesel & Turbo.

  20. [A multimodal strategy to improve adherence to hand hygiene in a university hospital].

    PubMed

    Fariñas-Alvarez, C; Portal-María, T; Flor-Morales, V; Aja-Herrero, A; Fabo-Navarro, M; Lanza-Marín, S; Lobeira-Rubio, R; Polo-Hernández, N; Sixto-Montero, M; Moreta-Sánchez, R; Ballesteros-Sanz, M Á; Yañez-San Segundo, L; Bartalome-Pacheco, M J; Armiñanzas-Castillo, C

    Within the framework of the PaSQ (Patient Safety and Quality care) Project, this hospital decided to implement a multifaceted hospital-wide Hand Hygiene (HH) intervention based on a multimodal WHO approach over one year, focusing on achieving a sustained change in HH cultural change in this hospital. Setting: University Hospital Marqués de Valdecilla, Santander (Spain), a tertiary hospital with 900 beds. Intervention period: 2014. An action plan was developed that included the implementation of activities in each component of the 5-step multimodal intervention. An observation/feedback methodology was used that included the provision of performance and results feedback to the staff. A 3/3 strategy (non-blinded direct observation audits performed during 3 randomised days every 3 weeks with pro-active corrective actions at the end of each observation period). HH compliance, alcohol-based hand-rub (ABHR) consumption, and rate of MRSA infection, were monitored during the intervention. Hospital ABHR consumption increased during the study period: from 17.5 to 19.7mL/patient-days. In the intervention units, this consumption was 24.8mL pre-intervention, 42.5mL during the intervention, and 30.4mL two months post-intervention. There were 137 evaluation periods in 30 different days, in which a total of 737 health-care workers were observed and 1,870 HH opportunities. HH compliance was 54.5%, ranging between 44.8% and 69.9%. The incidence of MRSA infection decreased during the intervention in the selected units, from 13.2 infections per 10,000 patient-days pre-intervention to 5.7 three months post-intervention. Our HH strategy, supported by a 3/3 strategy increased alcohol-based hand-rub consumption and compliance. A reduction in MRSA infections was observed. Copyright © 2016 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Hand washing with soap and water together with behavioural recommendations prevents infections in common work environment: an open cluster-randomized trial

    PubMed Central

    2012-01-01

    Background Hand hygiene is considered as an important means of infection control. We explored whether guided hand hygiene together with transmission-limiting behaviour reduces infection episodes and lost days of work in a common work environment in an open cluster-randomized 3-arm intervention trial. Methods A total of 21 clusters (683 persons) were randomized to implement hand hygiene with soap and water (257 persons), with alcohol-based hand rub (202 persons), or to serve as a control (224 persons). Participants in both intervention arms also received standardized instructions on how to limit the transmission of infections. The intervention period (16 months) included the emergence of the 2009 influenza pandemic and the subsequent national hand hygiene campaign influencing also the control arm. Results In the total follow-up period there was a 6.7% reduction of infection episodes in the soap-and water arm (p = 0.04). Before the onset of the anti-pandemic campaign, a statistically significant (p = 0.002) difference in the mean occurrence of infection episodes was observed between the control (6.0 per year) and the soap-and-water arm (5.0 per year) but not between the control and the alcohol-rub arm (5.6 per year). Neither intervention had a decreasing effect on absence from work. Conclusions We conclude that intensified hand hygiene using water and soap together with behavioural recommendations can reduce the occurrence of self-reported acute illnesses in common work environment. Surprisingly, the occurrence of reported sick leaves also increased in the soap-and water-arm. Trial Registration ClinicalTrials.gov: NCT00981877 Source of funding The Finnish Work Environment Fund and the National Institute for Health and Welfare. PMID:22243622

  2. 40 CFR 86.146-96 - Fuel dispensing spitback procedure.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... laboratory. (i) The fueling procedure consists of dispensing fuel through a nozzle, interrupted by a series... or methanol. The bag shall be designed and used so that liquid fuel does not spit back onto the... the orifice of the filler pipe. The bag must be designed to permit passage of the dispensing nozzle...

  3. 40 CFR 86.146-96 - Fuel dispensing spitback procedure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... laboratory. (i) The fueling procedure consists of dispensing fuel through a nozzle, interrupted by a series... or methanol. The bag shall be designed and used so that liquid fuel does not spit back onto the... the orifice of the filler pipe. The bag must be designed to permit passage of the dispensing nozzle...

  4. 40 CFR 86.1246-96 - Fuel dispensing spitback procedure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... laboratory. (i) The fueling procedure consists of dispensing fuel through a nozzle, interrupted by a series... or methanol. The bag shall be designed and used so that liquid fuel does not spit back onto the... the orifice of the filler pipe. The bag must be designed to permit passage of the dispensing nozzle...

  5. 40 CFR 86.1246-96 - Fuel dispensing spitback procedure.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... laboratory. (i) The fueling procedure consists of dispensing fuel through a nozzle, interrupted by a series... or methanol. The bag shall be designed and used so that liquid fuel does not spit back onto the... the orifice of the filler pipe. The bag must be designed to permit passage of the dispensing nozzle...

  6. Evaluation of medicines dispensing pattern of private pharmacies in Rajshahi, Bangladesh.

    PubMed

    Saha, Shuvashis; Hossain, Md Tawhid

    2017-02-13

    In developing country like BANGLADESH, people depend more on pharmacies due to expediency, shorter waiting time, cost reduction, availability of credit and flexible opening hours. The aim of this study was to investigate medicines dispensing patterns of the pharmacies in RAJSHAHI, BANGLADESH and to identify and analyze contribution of drugsellers and quacks in irrational drug use. This cross-sectional study was conducted during January 2016 - April, 2016 in 75 randomly selected private pharmacies including both licensed and unlicensed pharmacies of covering LAKSHMIPUR area. During the whole study process, total 7944 clients visited the pharmacies under observation and 24,717 medicines were dispensed. 22.70% of all these drugs were sold without a prescription. Out of the 5610 items dispensed without prescription, 66.2% were dispensed on the request of clients themselves and 33.8% on the recommendation of a drug seller. Number of medicine in a prescription was highly variable ranging from 2 to 5 medicines per prescriptions (mean = 3.03). The average number of medicines dispensed from each of the pharmacies during the observation period was 392, varied pharmacy to pharmacy - ranging from 194 to 588. Lowest selling medicines were sedative and hypnotics and highest selling medicines were antimicrobials. The recommendation rate for antibiotics was highest for the quacks (26.48%) though the major amount of the antimicrobials (n = 3039, 65.83%) were dispensed on prescription. Macrolides, quinolones, metronidazoles and cephalosporins are most favourite drug of quacks, clients and pharmacists. Majority of medicines were dispensed irrationally without any prescription and over the counter dispensing of many low safety profile drugs was common. The results and discussion presented in this paper will be helpful to provide a baseline to redirect further studies in this area.

  7. Replication of Holograms with Corn Syrup by Rubbing

    PubMed Central

    Mejias-Brizuela, Nildia Y.; Olivares-Pérez, Arturo; Ortiz-Gutiérrez, Mauricio

    2012-01-01

    Corn syrup films are used to replicate holograms in order to fabricate micro-structural patterns without the toxins commonly found in photosensitive salts and dyes. We use amplitude and relief masks with lithographic techniques and rubbing techniques in order to transfer holographic information to corn syrup material. Holographic diffraction patterns from holographic gratings and computer Fourier holograms fabricated with corn syrup are shown. We measured the diffraction efficiency parameter in order to characterize the film. The versatility of this material for storage information is promising. Holographic gratings achieved a diffraction efficiency of around 8.4% with an amplitude mask and 36% for a relief mask technique. Preliminary results using corn syrup as an emulsion for replicating holograms are also shown in this work.

  8. Development of an Automatic Dispensing System for Traditional Chinese Herbs.

    PubMed

    Lin, Chi-Ying; Hsieh, Ping-Jung

    2017-01-01

    The gathering of ingredients for decoctions of traditional Chinese herbs still relies on manual dispensation, due to the irregular shape of many items and inconsistencies in weights. In this study, we developed an automatic dispensing system for Chinese herbal decoctions with the aim of reducing manpower costs and the risk of mistakes. We employed machine vision in conjunction with a robot manipulator to facilitate the grasping of ingredients. The name and formulation of the decoction are input via a human-computer interface, and the dispensing of multiple medicine packets is performed automatically. An off-line least-squared curve fitting method was used to calculate the amount of material grasped by the claws and thereby improve system efficiency as well as the accuracy of individual dosages. Experiments on the dispensing of actual ingredients demonstrate the feasibility of the proposed system.

  9. Gender and age differences in medications dispensed from a national chain drugstore.

    PubMed

    Anthony, Marietta; Lee, Kwan Y; Bertram, Carl T; Abarca, Jacob; Rehfeld, Rick A; Malone, Daniel C; Freeman, Marlene; Woosley, Raymond L

    2008-06-01

    Our objective was to compare sex and age differences in the medications dispensed in pharmacies from a large national drugstore chain. Using a list for the 200 most commonly prescribed medicines, we assessed prescriptions dispensed by a large national chain drug store over 1 year (2002-2003). The analysis used U.S. census data adjusted for the population by sex and age and weighted by the number of pharmacies per state. Results are reported as an odds ratio (OR) of prescriptions dispensed to females and males. Under age 18, 24 drug classes were dispensed more commonly to females (OR > 1) and 18 drug classes more commonly to males (OR < 1). In the 18-24 age group, 48 of 53 drug classes were dispensed more frequently to females. Across other adult groups, females were dispensed more medications than males for 156 of 180 medications. There was greater dispensing to females of antibiotics (OR = 1.74, 95% confidence interval [CI] 1.74-1.74), analgesics (OR = 1.70, 95% CI 1.70-1.70), antihistamines and sympathomimetics (OR = 1.46, 95% CI 1.45-1.46), benzodiazapines (OR = 2.08, 95% CI 2.07-2.08), antidepressants (OR = 2.40, 95% CI 2.39-2.40), diuretics (OR = 1.9328, 95% CI 1.93-1.94), and thyroid drugs (OR = 4.80, 95% CI 4.78-4.82). However, males had higher dispensing of antianginal drugs (OR = 0.84, 95% CI 0.83-0.85), anticoagulants (OR = 0.89, 95% CI 0.88-0.90), glycosides (OR = 0.80, 95% CI 0.79-0.81), and antihypertensives (OR = 0.91, 95% CI 0.91-0.91). More females were dispensed propoxyphene with acetaminophen (OR = 2.23, 95% CI 2.23-2.24), which has been associated with adverse outcomes (hospitalizations, emergency department visits, and deaths). Females, especially during the reproductive years, are dispensed more medications than males.

  10. Foam soap is not as effective as liquid soap in eliminating hand microbial flora.

    PubMed

    Dixon, Nicolette; Morgan, Margie; Equils, Ozlem

    2017-07-01

    Foam soaps are aerosolized liquid soaps dispensed through a special pump mechanism. Currently there are no studies comparing liquid soap with foam soap in regard to efficacy of reducing hand microbial burden. In 3 separate experiments and with 2 different brands of foam soap, it was observed that nonantimicrobial foam soap was not as effective in reducing hand bacterial load as the liquid soap. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  11. 48 CFR 37.116 - Accepting and Dispensing of $1 Coin.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Accepting and Dispensing of $1 Coin. 37.116 Section 37.116 Federal Acquisition Regulations System FEDERAL ACQUISITION... and Dispensing of $1 Coin. [72 FR 46362, Aug. 17, 2007] ...

  12. 48 CFR 37.116 - Accepting and Dispensing of $1 Coin.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Accepting and Dispensing of $1 Coin. 37.116 Section 37.116 Federal Acquisition Regulations System FEDERAL ACQUISITION... and Dispensing of $1 Coin. [72 FR 46362, Aug. 17, 2007] ...

  13. Pharmacists' role in opioid overdose: Kentucky pharmacists' willingness to participate in naloxone dispensing.

    PubMed

    Freeman, Patricia R; Goodin, Amie; Troske, SuZanne; Strahl, Audra; Fallin, Amanda; Green, Traci C

    To assess pharmacists' willingness to initiate the dispensing of naloxone. As of 2015, Kentucky law permits certified pharmacists to dispense naloxone under a physician-approved protocol. Electronic survey (e-mail) gauging perception of pharmacists' role in opioid overdose and attitudes toward, and barriers to, naloxone dispensing. All Kentucky pharmacists with active licenses in 2015. Ordinal logistic regression was used to estimate the impact of pharmacist characteristics and attitudes on willingness to initiate naloxone dispensing, where the dependent variable was operationalized as a Likert-type question on a scale of 1 (not at all willing) to 6 (very willing). Of 4699 practicing Kentucky pharmacists, 1282 responded, of which 834 were community practitioners (response rate 27.3%). Pharmacists reported varying willingness to initiate naloxone dispensing, with 37.3% very willing (score 5 or 6) and 27.9% not willing (score 1 or 2). However, a majority of pharmacists reported willingness to dispense naloxone with a valid prescription (54.0%, score 5 or 6). Women pharmacists were 1.3 times more likely than men to be willing to initiate naloxone dispensing (95% confidence interval [CI] 1.0-1.6). Those who reported confidence in identifying individuals at risk for overdose were 1.2 times more likely to initiate dispensing, and those who reported confidence in ability to educate patients about overdose were 1.6 times more likely to express willingness to initiate naloxone dispensing (95% CIs, respectively, 1.0-1.3 and 1.4-1.8). Community pharmacists reported barriers to naloxone access at higher rates than pharmacists from other practice settings. Kentucky pharmacists are divided in their willingness to initiate naloxone dispensing; however, those who are confident in their ability to identify overdose risks are more willing. Increasing pharmacist confidence through appropriately designed education programs could facilitate pharmacist participation in naloxone

  14. Analysis of costs to dispense prescriptions in independently owned, closed-door long-term care pharmacies.

    PubMed

    Carroll, Norman V; Rupp, Michael T; Holdford, David A

    2014-03-01

    The need for accurate calculation of long-term care (LTC) pharmacies' costs to dispense (CTD) has become more important as payers have moved toward reimbursement models based on pharmacies' actual acquisition cost for drug products and the Centers for Medicare Medicaid Services (CMS) has implemented requirements that LTC pharmacies must dispense prescriptions for certain branded drugs in 14-day-or-less quantities. To (a) calculate the average cost that the typical independently owned, closed-door LTC pharmacy currently incurs to dispense and deliver a prescription to the resident of a client LTC facility and (b) estimate how CMS-mandated changes to a 14-day-or-less dispensing cycle would affect the typical LTC pharmacy's average CTD. The data requirements and measurement model were developed by academic researchers in consultation with an industry advisory committee of independent LTC pharmacy owners. A survey instrument was constructed to collect financial and operating data required to calculate the CTD. Surveys were distributed via 3 dissemination channels to approximately 1,000 independently owned, closed-door LTC pharmacies. The National Community Pharmacists Association mailed surveys to their LTC members; 3 major national wholesalers distributed surveys to their LTC customers through their newsletters; and 3 LTC group purchasing organizations distributed the surveys to their members through emails, newsletters, mailings, and/or regional meetings. Each pharmacy's CTD was calculated by dividing total LTC dispensing-related 
costs by the total number of prescriptions dispensed. Dispensing-related costs included costs incurred to physically dispense and deliver prescriptions (e.g., dispensing pharmacists' and technicians' salaries and costs of medication containers) and costs incurred to support the dispensing function (e.g., salaries of delivery and medical records personnel). A model based on dispensing-related fixed, variable, and semivariable costs was

  15. Pointing and pantomime in wild apes? Female bonobos use referential and iconic gestures to request genito-genital rubbing

    PubMed Central

    Douglas, Pamela Heidi; Moscovice, Liza R.

    2015-01-01

    Referential and iconic gesturing provide a means to flexibly and intentionally share information about specific entities, locations, or goals. The extent to which nonhuman primates use such gestures is therefore of special interest for understanding the evolution of human language. Here, we describe novel observations of wild female bonobos (Pan paniscus) using referential and potentially iconic gestures to initiate genito-genital (GG) rubbing, which serves important functions in reducing social tension and facilitating cooperation. We collected data from a habituated community of bonobos at Luikotale, DRC, and analysed n = 138 independent gesture bouts made by n = 11 females. Gestures were coded in real time or from video. In addition to meeting the criteria for intentionality, in form and function these gestures resemble pointing and pantomime–two hallmarks of human communication–in the ways in which they indicated the relevant body part or action involved in the goal of GG rubbing. Moreover, the gestures led to GG rubbing in 83.3% of gesture bouts, which in turn increased tolerance in feeding contexts between the participants. We discuss how biologically relevant contexts in which individuals are motivated to cooperate may facilitate the emergence of language precursors to enhance communication in wild apes. PMID:26358661

  16. Separation of prescribing and dispensing in Malaysia: the history and challenges.

    PubMed

    Tiong, John Jeh Lung; Mai, Chun Wai; Gan, Pou Wee; Johnson, James; Mak, Vivienne Sook Li

    2016-08-01

    This article serves as an update to the work by Shafie et al. (2012) which previously reviewed the benefits of policies separating prescribing and dispensing in various countries to advocate its implementation in Malaysia. This article seeks to strengthen the argument by highlighting not only the weaknesses of the Malaysian health care system from the historical, professional and economic viewpoints but also the shortcomings of both medical and pharmacy professions in the absence of separation of dispensing. It also provides a detailed insight into the ongoing initiatives taken to consolidate the role of pharmacists in the health care system in the advent of separation of dispensing. Under the two tier system in Malaysia at present, the separation of prescribing and dispensing is implemented only in government hospitals. The absence of this separation in the private practices has led to possible profit-oriented medical and pharmacy practices which hinder safe and cost-effective delivery of health services. The call for separation of dispensing has gained traction over the years despite various hurdles ranging from the formidable resistance from the medical fraternity to the public's scepticism towards the new policy. With historical testament and present evidence pointing towards the merits of a system in which doctors prescribe and pharmacists dispense, the implementation of this health care model is justified. © 2016 The Authors. IJPP © 2016 Royal Pharmaceutical Society.

  17. IoT for Real-Time Measurement of High-Throughput Liquid Dispensing in Laboratory Environments.

    PubMed

    Shumate, Justin; Baillargeon, Pierre; Spicer, Timothy P; Scampavia, Louis

    2018-04-01

    Critical to maintaining quality control in high-throughput screening is the need for constant monitoring of liquid-dispensing fidelity. Traditional methods involve operator intervention with gravimetric analysis to monitor the gross accuracy of full plate dispenses, visual verification of contents, or dedicated weigh stations on screening platforms that introduce potential bottlenecks and increase the plate-processing cycle time. We present a unique solution using open-source hardware, software, and 3D printing to automate dispenser accuracy determination by providing real-time dispense weight measurements via a network-connected precision balance. This system uses an Arduino microcontroller to connect a precision balance to a local network. By integrating the precision balance as an Internet of Things (IoT) device, it gains the ability to provide real-time gravimetric summaries of dispensing, generate timely alerts when problems are detected, and capture historical dispensing data for future analysis. All collected data can then be accessed via a web interface for reviewing alerts and dispensing information in real time or remotely for timely intervention of dispense errors. The development of this system also leveraged 3D printing to rapidly prototype sensor brackets, mounting solutions, and component enclosures.

  18. 21 CFR 1307.11 - Distribution by dispenser to another practitioner or reverse distributor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... practitioner who is registered to dispense a controlled substance may distribute (without being registered to distribute) a quantity of such substance to— (1) Another practitioner for the purpose of general dispensing... is to be distributed is registered under the Act to dispense that controlled substance; (ii) The...

  19. Feasibility study of a biocompatible pneumatic dispensing system using mouse 3T3-J2 fibroblasts

    NASA Astrophysics Data System (ADS)

    Lee, Sangmin; Kim, Hojin; Kim, Joonwon

    2017-12-01

    This paper presents results for dispensing living cells using a pneumatic dispensing system to verify the feasibility of using this system to fabricate biomaterials. Living cells (i.e., mouse 3T3-J2 fibroblast) were dispensed with different dispensing pressures in order to evaluate the effect of dispensing process on cell viability and proliferation. Based on the results of a live-dead assay, more than 80% of cell viability has been confirmed which was reasonably similar to that in the control group. Furthermore, measurement of cell metabolic activity after dispensing confirmed that the dispensed cell proliferated at a rate comparable to that of the control group. These results demonstrate that the pneumatic dispensing system is a promising tool for fabrication of biomaterials.

  20. Foam-Mixing-And-Dispensing Machine

    NASA Technical Reports Server (NTRS)

    Chong, Keith Y.; Toombs, Gordon R.; Jackson, Richard J.

    1996-01-01

    Time-and-money-saving machine produces consistent, homogeneously mixed foam, enhancing production efficiency. Automatically mixes and dispenses polyurethane foam in quantities specified by weight. Consists of cart-mounted, air-driven proportioning unit; air-activated mechanical mixing gun; programmable timer/counter, and controller.

  1. Effect of electronic real-time prompting on hand hygiene behaviors in health care workers.

    PubMed

    Pong, Steven; Holliday, Pamela; Fernie, Geoff

    2018-03-02

    Poor hand hygiene by health care workers is a major cause of nosocomial infections. This research evaluated the ability of an electronic monitoring system with real-time prompting capability to change hand hygiene behaviors. Handwashing activity was measured by counting dispenser activations on a single nursing unit before, during, and after installation of the system. The effect of changing the prompt duration on hand hygiene performance was determined by a cluster-randomized trial on 3 nursing units with 1 acting as control. Sustainability of performance and participation was observed on 4 nursing units over a year. All staff were eligible to participate. Between June 2015 and December 2016, a total of 459,376 hand hygiene opportunities and 330,740 handwashing events from 511 staff members were recorded. Dispenser activation counts were significantly influenced by use of the system (χ 2 [3] = 75.76; P < .0001). Hand hygiene performance dropped from 62.61% to 24.94% (odds ratio, 0.36; 95% confidence interval, 0.34-0.38) when the prompting feature was removed. Staff participation had a negative trajectory of -0.72% (P < .001), whereas change in average performance was -0.18% (P < .001) per week for the year. Use of electronic monitoring with real-time prompts of 20 seconds' duration nearly doubles handwashing activity and causes handwashing to occur sooner after entering a patient room. These improvements are sustainable over a year. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. Optimizing the Point-Source Emission Rates and Geometries of Pheromone Mating Disruption Mega-Dispensers.

    PubMed

    Baker, T C; Myrick, A J; Park, K C

    2016-09-01

    High-emission-rate "mega-dispensers" have come into increasing use for sex pheromone mating disruption of moth pests over the past two decades. These commercially available dispensers successfully suppress mating and reduce crop damage when they are deployed at very low to moderate densities, ranging from 1 to 5/ha to 100-1000/ha, depending on the dispenser types and their corresponding pheromone emission rates. Whereas traditionally the emission rates for successful commercial mating disruption formulations have been measured in terms of amounts (usually milligram) emitted by the disruptant application per acre or hectare per day, we suggest that emission rates should be measured on a per-dispenser per-minute basis. In addition we suggest, because of our knowledge concerning upwind flight of male moths being dependent on contact with pheromone plume strands, that more attention needs to be paid to optimizing the flux within plume strands that shear off of any mating disruption dispenser's surface. By measuring the emission rates on a per-minute basis and measuring the plume strand concentrations emanating from the dispensers, it may help improve the ability of the dispensers to initiate upwind flight from males and initiate their habituation to the pheromone farther downwind than can otherwise be achieved. In addition, by optimizing plume strand flux by paying attention to the geometries and compactness of mating disruption mega-dispensers may help reduce the cost of mega-dispenser disruption formulations by improving their behavioral efficacy while maintaining field longevity and using lower loading rates per dispenser.

  3. Factors associated with hand hygiene practices in two neonatal intensive care units.

    PubMed

    Cohen, Bevin; Saiman, Lisa; Cimiotti, Jeannie; Larson, Elaine

    2003-06-01

    To determine whether hand hygiene practices differ between levels of contact with neonates; to characterize the hand hygiene practices of different types of personnel; and to compare hand hygiene practices in neonatal intensive care units (NICUs) using different products. Research assistants observed staff hand hygiene practices during 38 sessions in two NICUs. Patient touches were categorized as touching within the neonates' environment but only outside the Isolette (Level 1), touching within the Isolette but not the neonate directly (Level 2) or directly touching the neonate (Level 3). Hand hygiene practices for each touch were categorized into five groups: cleaned hands and new gloves; uncleaned hands and new gloves; used gloves; clean hands and no gloves; uncleaned hands and no gloves. Research assistants observed 1472 touches. On average each neonate or his or her immediate environment was touched 78 times per shift. Nurses (P = 0.001), attending physicians (P = 0.02) and physicians-in-training (P = 0.03) were more likely to use appropriate practices during Level 3 touches, but only 22.8% of all touches were with cleaned and/or newly gloved hands. The mean number of direct touches by staff members with cleaned hands was greater in the NICU using an alcohol-based hand rub than in the NICU using antimicrobial soap (P < 0.01). Hand hygiene was suboptimal in this high risk setting; administrative action and improved products may be needed to assure acceptable practice. In this study use of an alcohol-based product was associated with significantly improved hand hygiene and should be encouraged, as recommended in the new CDC hand hygiene guideline.

  4. Dispensing Processes Impact Apparent Biological Activity as Determined by Computational and Statistical Analyses

    PubMed Central

    Ekins, Sean; Olechno, Joe; Williams, Antony J.

    2013-01-01

    Dispensing and dilution processes may profoundly influence estimates of biological activity of compounds. Published data show Ephrin type-B receptor 4 IC50 values obtained via tip-based serial dilution and dispensing versus acoustic dispensing with direct dilution differ by orders of magnitude with no correlation or ranking of datasets. We generated computational 3D pharmacophores based on data derived by both acoustic and tip-based transfer. The computed pharmacophores differ significantly depending upon dispensing and dilution methods. The acoustic dispensing-derived pharmacophore correctly identified active compounds in a subsequent test set where the tip-based method failed. Data from acoustic dispensing generates a pharmacophore containing two hydrophobic features, one hydrogen bond donor and one hydrogen bond acceptor. This is consistent with X-ray crystallography studies of ligand-protein interactions and automatically generated pharmacophores derived from this structural data. In contrast, the tip-based data suggest a pharmacophore with two hydrogen bond acceptors, one hydrogen bond donor and no hydrophobic features. This pharmacophore is inconsistent with the X-ray crystallographic studies and automatically generated pharmacophores. In short, traditional dispensing processes are another important source of error in high-throughput screening that impacts computational and statistical analyses. These findings have far-reaching implications in biological research. PMID:23658723

  5. Hydrogen, CNG, and HCNG Dispenser System – Prototype Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James Francfort

    2005-02-01

    The U.S. Department of Energy’s Advanced Vehicle Testing Activity is currently testing a prototype gaseous fuel dispenser developed by the Electric Transportation Engineering Corporation (ETEC). The dispenser (Figure 1) delivers three types of fuels: 100% hydrogen, 100% compressed natural gas (CNG), and blends of hydrogen and CNG (HCNG) using two independent single nozzles (Figure 2). The nozzle for the 100% hydrogen dispensing is rated at 5,000 psig and used solely for 100% hydrogen fuel. The second nozzle is rated at 3,600 psig and is used for both CNG and HCNG fuels. This nozzle connects to both a CNG supply linemore » and a hydrogen supply line and blends the hydrogen and CNG to supply HCNG levels of 15, 20, 30, and 50% (by volume).« less

  6. A study of the additional costs of dispensing workers' compensation prescriptions.

    PubMed

    Schafermeyer, Kenneth W

    2007-03-01

    Although there is a significant amount of additional work involved in dispensing workers' compensation prescriptions, these costs have not been quantified. A study of the additional costs to dispense a workers' compensation prescription is needed to measure actual costs and to help determine the reasonableness of reimbursement for prescriptions dispensed under workers' compensation programs. The purpose of this study was to determine the minimum additional time and costs required to dispense workers' compensation prescriptions in Texas. A convenience sample of 30 store-level pharmacy staff members involved in submitting and processing prescription claims for the Texas Mutual workers' compensation program were interviewed by telephone. Data collected to determine the additional costs of dispensing a workers' compensation prescription included (1) the amount of additional time and personnel costs required to dispense and process an average workers' compensation prescription claim, (2) the difference in time required for a new versus a refilled prescription, (3) overhead costs for processing workers' compensation prescription claims by experienced experts at a central processing facility, (4) carrying costs for workers' compensation accounts receivable, and (5) bad debts due to uncollectible workers' compensation claims. The median of the sample pharmacies' additional costs for dispensing a workers' compensation prescription was estimated to be at least $9.86 greater than for a cash prescription. This study shows that the estimated costs for workers' compensation prescriptions were significantly higher than for cash prescriptions. These costs are probably much more than most employers, workers' compensation payers, and pharmacy managers would expect. It is recommended that pharmacy managers should estimate their own costs and compare these costs to actual reimbursement when considering the reasonableness of workers' compensation prescriptions and whether to accept

  7. Adherence to national recommendations for safe methotrexate dispensing in community pharmacies.

    PubMed

    Koster, Ellen S; Walgers, Joelle C D; van Grinsven, Mariska C J; Winters, Nina A; Bouvy, Marcel L

    2014-02-01

    The number of patients using methotrexate (MTX) has increased during the last decade. Because of the narrow therapeutic range and potential risks of incorrect use, vigilance is required when dispensing MTX. In 2009, the Royal Dutch Pharmacists Society, in accordance with the Dutch Health Care Inspectorate, published safe MTX dispensing recommendations for community pharmacies. To examine adherence to recommendations aimed at safe 
MTX dispensing. This study was conducted within a convenience sample of 78 community pharmacies belonging to the Utrecht Pharmacy Practice Network for Education and Research (UPPER). Data were collected in May 2011. 95 pharmacists and 337 pharmacy technicians were interviewed to assess self-reported adherence with dispensing recommendations. In addition, medication records for patients using MTX were extracted in 52 pharmacies in order to objectively assess adoption of recommendations. More than 75% of the pharmacists and pharmacy technicians reported to be adherent to 6 of the 11 recommendations. There are variations in reported adherence between team members working in 1 pharmacy; higher adherence rates ( greater than 75%) for the pharmacy team as a whole were only shown for 2 recommendations (recording of day of intake on the label and moment of authorization by the pharmacist). The medication records showed that adherence with working procedures significantly increased: The number of dispensed records with notification of the day of intake on the medication label increased from 9.9% of the records per pharmacy in 2008 to 77.1% in 2010 (P  less than  0.001). Dutch community pharmacies seem to be adherent to most safe dispensing recommendations. However, inconsistencies exist between team members that emphasize the importance of addressing this issue and discussing recommendations within the team, as there is still room for improvement to ensure safe dispensing.

  8. Prescription opioid analgesics for pain management in Australia: 20 years of dispensing.

    PubMed

    Islam, M M; McRae, I S; Mazumdar, S; Taplin, S; McKetin, R

    2016-08-01

    Opioid prescribing/dispensing data can inform policy surrounding regulation by informing trends and types of opioid prescribed and geographic variations. In Australia so far only partial data on dispensing have been published, and data for states/territories remain unknown. Using a range of measures, this study examines 20-year (1992-2011) trends in prescription opioid analgesics in Australia - both nationally and for individual jurisdictions. Dispensing data were obtained from the Drug Utilisation Sub-Committee and the Pharmaceutical Benefits Scheme (PBS) websites. Trends in numbers of prescriptions and daily defined dose (DDD)/1000 people/day were examined over time and across states/territories. Seasonal variations in PBS/Repatriation Pharmaceutical Benefits Scheme (RPBS) items for nationwide dispensing were adjusted using a centred moving smoothing technique. In two decades, 165.32 million prescriptions for opioids were dispensed, with codeine and its derivatives the most prescribed formulation (50.1%) followed by tramadol (13.5%) and oxycodone derivatives (12.7%). In terms of DDD/1000 people/day, dispensing increased from 5.38 in 1992 to 14.46 in 2011. There are significant increasing trends for total, PBS/RPBS and under co-payment prescriptions (priced below patient co-payment). The DDD/1000 people/day for items dispensed through PBS/RPBS was highest in Tasmania. Prescription opioid dispensing increased substantially over the study period. With an ageing population, this trend is likely to continue in future. A growing concern about harms associated with opioid use warrants balanced control measures so that harms could be minimised without reducing effective pain treatment. Research examining utilisation in small geographic areas may help design spatially tailored interventions. A real-time drug-monitoring programme may reduce undue prescribing and dispensing. © 2016 Royal Australasian College of Physicians.

  9. Texture Rubbings

    ERIC Educational Resources Information Center

    Szekely, George

    2011-01-01

    As hands-on environmental observers, children use printing to save and share "treasures" they find. In this article, the author shares thoughts which are based on observing what children find valuable and worth saving, and the printmaking processes used to "lift" images from their finds.

  10. Hand hygiene with soap and water is superior to alcohol rub and antiseptic wipes for removal of Clostridium difficile.

    PubMed

    Oughton, Matthew T; Loo, Vivian G; Dendukuri, Nandini; Fenn, Susan; Libman, Michael D

    2009-10-01

    To evaluate common hand hygiene methods for efficacy in removing Clostridium difficile. Randomized crossover comparison among 10 volunteers with hands experimentally contaminated by nontoxigenic C. difficile. Interventions included warm water with plain soap, cold water with plain soap, warm water with antibacterial soap, antiseptic hand wipes, alcohol-based handrub, and a control involving no intervention. All interventions were evaluated for mean reduction in colony-forming units (CFUs) under 2 contamination protocols: "whole hand" and "palmar surface." Results were analyzed according to a Bayesian approach, by using hierarchical models adjusted for multiple observations. Under the whole-hand protocol, the greatest adjusted mean reductions were achieved by warm water with plain soap (2.14 log(10) CFU/mL [95% credible interval (CrI), 1.74-2.54 log(10) CFU/mL]), cold water with plain soap (1.88 log(10) CFU/mL [95% CrI, 1.48-2.28 log(10) CFU/mL), and warm water with antibacterial soap (1.51 log(10) CFU/mL [95% CrI, 1.12-1.91 log(10) CFU/mL]), followed by antiseptic hand wipes (0.57 log(10) CFU/mL [95% CrI, 0.17-0.96 log(10) CFU/mL]). Alcohol-based handrub (0.06 log(10) CFU/mL [95% CrI, -0.34 to 0.45 log(10) CFU/mL]) was equivalent to no intervention. Under the palmar surface protocol, warm water with plain soap, cold water with plain soap, and warm water with antibacterial soap again yielded the greatest mean reductions, followed by antiseptic hand wipes (26.6, 26.6, 26.6, and 21.9 CFUs per plate, respectively), when compared with alcohol-based handrub. Hypothenar (odds ratio, 10.98 [95% CrI, 1.96-37.65]) and thenar (odds ratio, 6.99 [95% CrI, 1.25-23.41]) surfaces were more likely than fingertips to remain heavily contaminated after handwashing. Handwashing with soap and water showed the greatest efficacy in removing C. difficile and should be performed preferentially over the use of alcohol-based handrubs when contact with C. difficile is suspected or likely.

  11. Investigation of thermal degradation with extrusion-based dispensing modules for 3D bioprinting technology.

    PubMed

    Lee, Hyungseok; Yoo, James J; Kang, Hyun-Wook; Cho, Dong-Woo

    2016-02-04

    Recently, numerous three-dimensional (3D) bioprinting systems have been introduced for the artificial regeneration of tissues. Among them, the extrusion-based dispensing module is the most widely used because of the processability it gives various biomaterials. The module uses high forces and temperature to dispense materials through a micro-nozzle. Generally, the harsh conditions induce thermal degradation of the material in the dispensing procedure. The thermal degradation affects the properties of the materials, and the change of the properties should be carefully controlled, because it severely affects the regeneration of tissues. Therefore, in this research, the relationship between the dispensing module and the thermal degradation of material was investigated. Extrusion-based dispensing modules can be divided into the syringe type (ST) and filament type (FT) based on working principles. We prepared a poly lactic-co-glycolic acid (PLGA) scaffold with the two methods at various time points. Then, the characteristics of the printed scaffolds were assessed by measuring molecular weight (M w), glass transition temperature (T g), in vitro degradation, compressive modulus, and cytocompatibility. The results showed that the PLGA scaffold with the FT dispensing module maintained its properties regardless of printing time points. In contrast, severe thermal degradation was observed in the scaffold group prepared by the ST dispensing module. Consequentially, it was obvious that the FT dispensing module was more suitable for producing scaffolds without severe thermal degradation.

  12. Infection prevention and mass vaccination training for U.S. point of dispensing staff and volunteers: a national study.

    PubMed

    Rebmann, Terri; Loux, Travis M; Zink, Thomas K; Swick, Zachary; Wakefield, Mary

    2015-03-01

    Points of dispensing (PODs) are deployed for medical countermeasure mass dispensing. However, infection prevention and vaccine administration pre-event training offered and just-in-time (JIT) education planned for POD workers have not been assessed. Disaster planners were sent an online questionnaire in 2013. McNemar tests compared training offered to staff versus volunteers and pre-event training versus JIT training. In total, 301 disaster planners participated. The most frequent pre-event training included hand hygiene (59.1% and 28.0%) and personal protective equipment (PPE) selection (52.1% and 24.1%) for staff and volunteers, respectively. Few provided pre-event training on the cold chain technique (14.8% and 5.1%) or smallpox vaccine administration (4.7% and 2.3%) for staff or volunteers. For all topics except smallpox vaccine administration, more staff than volunteers received pre-event training (P < .01). The most frequent planned JIT training includes hand hygiene (79.8% and 73.5%) and PPE selection (79.4% and 70.0%) to staff and volunteers. For all topics, more JIT education is planned for staff than volunteers (P < .001). More JIT training is planned than has been given pre-event for all topics (P < .001). More pre-event training is needed on infection prevention and vaccine administration to ensure safe and successful POD deployment. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.

  13. Hand hygiene compliance in transplant and other special patient groups: an observational study.

    PubMed

    Graf, Karolin; Ott, Ella; Wolny, Michael; Tramp, Nadine; Vonberg, Ralf-Peter; Haverich, Axel; Chaberny, Iris Freya

    2013-06-01

    This study evaluates hand hygiene behavior of health care workers in a German university hospital stratified for treatment of special patient groups (eg, transplant patients). From 2008 to 2010, comprehensive education and training of all health care workers was implemented to improve hand hygiene compliance. Consumption rates of alcohol-based hand rub and gloves were collected and evaluated. Of the 5,647 opportunities of hand disinfection evaluated, 1,607 occurred during care for transplant patients. To our knowledge, this is the largest survey of hand hygiene compliance in special patient groups on intensive care units in a university hospital in Germany. Health care workers on surgical intensive care units showed lower hand hygiene compliance compared with health care workers on other types of intensive care units. Compliance toward hand hygiene was significantly higher on hemato-oncologic and pediatric wards. In general, hand disinfection was performed significantly more frequently after an intervention than before (P < .05, 95% confidence interval: 1.24-1.84). Overall, there was no significant difference in hand hygiene compliance when caring for transplant patients or other patients (odds ratio, 1.16; 95% confidence interval: 0.95-1.42). Nurse's and physician's hand hygiene compliance improved because of education. Hand hygiene compliance is not increased in the care for transplant patients (despite their predisposition for nosocomial infections) compared with other patients. Additional studies will be necessary to further investigate these findings. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  14. Rubbing skin with nylon towels as a major cause of pseudomonas folliculitis in a Japanese population.

    PubMed

    Teraki, Yuichi; Nakamura, Kaori

    2015-01-01

    Pseudomonas folliculitis (PF) is a community-acquired skin infection, which develops after exposure to contaminated water such as whirlpools, swimming pools, water slides and hot tubs. In Japan, this condition has been sporadically reported, often in association with bathing; however, the exact cause of PF in the Japanese population remains unclear. In this study, we retrospectively reviewed 10 patients with PF diagnosed at our dermatology clinic (two males and eight females). Four patients had recurrences over 1-3 years. Notably, eight of the 10 patients were rubbing their bodies with nylon towels or sponges placed in the bathrooms during bathing. Pseudomonas aeruginosa was isolated from the nylon towels used in two of the two patients examined. Discontinued use of nylon towels resulted in prompt resolution of PF and no recurrence in all cases. Our observation suggests that rubbing the skin with nylon towels contaminated with P. aeruginosa was a major cause of PF in a Japanese population. © 2014 Japanese Dermatological Association.

  15. Investigations on bending-torsional vibrations of rotor during rotor-stator rub using Lagrange multiplier method

    NASA Astrophysics Data System (ADS)

    Mokhtar, Md Asjad; Kamalakar Darpe, Ashish; Gupta, Kshitij

    2017-08-01

    The ever-increasing need of highly efficient rotating machinery causes reduction in the clearance between rotating and non-rotating parts and increase in the chances of interaction between these parts. The rotor-stator contact, known as rub, has always been recognized as one of the potential causes of rotor system malfunctions and a source of secondary failures. It is one of few causes that influence both lateral and torsional vibrations. In this paper, the rotor stator interaction phenomenon is investigated in the finite element framework using Lagrange multiplier based contact mechanics approach. The stator is modelled as a beam that can respond to axial penetration and lateral friction force during the contact with the rotor. It ensures dynamic stator contact boundary and more realistic contact conditions in contrast to most of the earlier approaches. The rotor bending-torsional mode coupling during contact is considered and the vibration response in bending and torsion are analysed. The effect of parameters such as clearance, friction coefficient and stator stiffness are studied at various operating speeds and it has been found that certain parameter values generate peculiar rub related features. Presence of sub-harmonics in the lateral vibration frequency spectra are prominently observed when the rotor operates near the integer multiple of its lateral critical speed. The spectrum cascade of torsional vibration shows the presence of bending critical speed along with the larger amplitudes of frequencies close to torsional natural frequency of the rotor. When m × 1/n X frequency component of rotational frequency comes closer to the torsional natural frequency, stronger torsional vibration amplitude is noticed in the spectrum cascade. The combined information from the stator vibration and rotor lateral-torsional vibration spectral features is proposed for robust rub identification.

  16. Can the design of glove dispensing boxes influence glove contamination?

    PubMed

    Assadian, O; Leaper, D J; Kramer, A; Ousey, K J

    2016-11-01

    Few studies have explored the microbial contamination of glove boxes in clinical settings. The objective of this observational study was to investigate whether a new glove packaging system in which single gloves are dispensed vertically, cuff end first, has lower levels of contamination on the gloves and on the surface around the box aperture compared with conventional glove boxes. Seven participating sites were provided with vertical glove dispensing systems (modified boxes) and conventional boxes. Before opening glove boxes, the surface around the aperture was sampled microbiologically to establish baseline levels of superficial contamination. Once the glove boxes were opened, the first pair of gloves in each box was sampled for viable bacteria. Thereafter, testing sites were visited on a weekly basis over a period of six weeks and the same microbiological assessments were made. The surface near the aperture of the modified boxes became significantly less contaminated over time compared with the conventional boxes (P<0.001), with an average of 46.7% less contamination around the aperture. Overall, gloves from modified boxes showed significantly less colony-forming unit contamination than gloves from conventional boxes (P<0.001). Comparing all sites over the entire six-week period, gloves from modified boxes had 88.9% less bacterial contamination. This simple improvement to glove box design reduces contamination of unused gloves. Such modifications could decrease the risk of microbial cross-transmission in settings that use gloves. However, such advantages do not substitute for strict hand hygiene compliance and appropriate use of non-sterile, single-use gloves. Copyright © 2016 The Healthcare Infection Society. All rights reserved.

  17. Older Adults’ Satisfaction with a Medication Dispensing Device in Home Care

    PubMed Central

    Demiris, George; Marek, Karen D.

    2014-01-01

    Introduction Older adults with multiple chronic conditions face the complex task of medication management involving multiple medications of varying doses at different times. Advances in telehealth technologies have resulted in home-based devices for medication management and health monitoring of older adults. We examined older adults’ perceptions of a telehealth medication dispensing device as part of a clinical trial involving home health care clients, nurse coordination and use of the medication dispensing device. Methods Ninety-six frail older adult participants who used the medication dispensing device for 12 months completed a satisfaction survey related to perceived usefulness and reliability. Results were analyzed and grouped by themes in the following areas: Ease of Use, Reliability, Medication Management Assistance, Routine Task Performance and Acceptability. Results Nearly all participants perceived the medication dispensing device as very easy to use, very reliable and helpful in management of their medications. Eighty-four percent of participants expressed a desire to use the machine in the future. Conclusion The technology-enhanced medication management device in this study is an acceptable tool for older adults to manage medication in collaboration with home care nurses. Improved usability and cost models for medication dispensers are areas for future research. Trial Registration clinicaltrials.gov identifier: NCT01321853 PMID:23323721

  18. “The 3/3 Strategy”: A Successful Multifaceted Hospital Wide Hand Hygiene Intervention Based on WHO and Continuous Quality Improvement Methodology

    PubMed Central

    Mestre, Gabriel; Berbel, Cristina; Tortajada, Purificación; Alarcia, Margarita; Coca, Roser; Gallemi, Gema; Garcia, Irene; Fernández, Mari Mar; Aguilar, Mari Carmen; Martínez, José Antonio; Rodríguez-Baño, Jesús

    2012-01-01

    Background Only multifaceted hospital wide interventions have been successful in achieving sustained improvements in hand hygiene (HH) compliance. Methodology/Principal Findings Pre-post intervention study of HH performance at baseline (October 2007– December 2009) and during intervention, which included two phases. Phase 1 (2010) included multimodal WHO approach. Phase 2 (2011) added Continuous Quality Improvement (CQI) tools and was based on: a) Increase of alcohol hand rub (AHR) solution placement (from 0.57 dispensers/bed to 1.56); b) Increase in frequency of audits (three days every three weeks: “3/3 strategy”); c) Implementation of a standardized register form of HH corrective actions; d) Statistical Process Control (SPC) as time series analysis methodology through appropriate control charts. During the intervention period we performed 819 scheduled direct observation audits which provided data from 11,714 HH opportunities. The most remarkable findings were: a) significant improvements in HH compliance with respect to baseline (25% mean increase); b) sustained high level (82%) of HH compliance during intervention; c) significant increase in AHRs consumption over time; c) significant decrease in the rate of healthcare-acquired MRSA; d) small but significant improvements in HH compliance when comparing phase 2 to phase 1 [79.5% (95% CI: 78.2–80.7) vs 84.6% (95% CI:83.8–85.4), p<0.05]; e) successful use of control charts to identify significant negative and positive deviations (special causes) related to the HH compliance process over time (“positive”: 90.1% as highest HH compliance coinciding with the “World hygiene day”; and “negative”:73.7% as lowest HH compliance coinciding with a statutory lay-off proceeding). Conclusions/Significance CQI tools may be a key addition to WHO strategy to maintain a good HH performance over time. In addition, SPC has shown to be a powerful methodology to detect special causes in HH performance (positive

  19. Room temperature rubbing for few-layer two-dimensional thin flakes directly on flexible polymer substrates

    PubMed Central

    Yu, Yan; Jiang, Shenglin; Zhou, Wenli; Miao, Xiangshui; Zeng, Yike; Zhang, Guangzu; Liu, Sisi

    2013-01-01

    The functional layers of few-layer two-dimensional (2-D) thin flakes on flexible polymers for stretchable applications have attracted much interest. However, most fabrication methods are “indirect” processes that require transfer steps. Moreover, previously reported “transfer-free” methods are only suitable for graphene and not for other few-layer 2-D thin flakes. Here, a friction based room temperature rubbing method is proposed for fabricating different types of few-layer 2-D thin flakes (graphene, hexagonal boron nitride (h-BN), molybdenum disulphide (MoS2), and tungsten disulphide (WS2)) on flexible polymer substrates. Commercial 2-D raw materials (graphite, h-BN, MoS2, and WS2) that contain thousands of atom layers were used. After several minutes, different types of few-layer 2-D thin flakes were fabricated directly on the flexible polymer substrates by rubbing procedures at room temperature and without any transfer step. These few-layer 2-D thin flakes strongly adhere to the flexible polymer substrates. This strong adhesion is beneficial for future applications. PMID:24045289

  20. Physician drug dispensing in Switzerland: association on health care expenditures and utilization.

    PubMed

    Trottmann, Maria; Frueh, Mathias; Telser, Harry; Reich, Oliver

    2016-07-08

    Several countries recently reassessed the roles of drug prescribing and dispensing, either by enlarging pharmacists' rights to prescribe (e.g. the US and the United Kingdom) or by limiting physicians' rights to dispense (e.g. Taiwan and South Korea). While integrating the two roles might increase supply and be convenient for patients, concern is that drug mark-ups incite providers to prescribe unnecessary drugs. We aimed to assess the association of physician dispensing (PD) in Switzerland on various outcomes. We performed a retrospective cohort study, using health care claims data for patients in the year 2013. The analysis of the association of PD was perfomed using a large patient level dataset and several target variables, including the number of different chemical agents, share of generic drugs, number of visits to physicians and expenditures. Different multivariate econometric models were applied in order to capture the association PD on the target variables. A total of 101'784 patients were enrolled in 2013, whereas 54 % were PD patients. We find that PD is associated with lower pharmaceutical expenditure per patient, which can be explained by an increased use of generic drugs. The decrease is compensated by higher use of physician services. We find no significant impact of physician dispensing on total health care expenditure. Our study offers insights for policy makers who are (re-)considering the separation between drug prescribing and dispensing, either by allowing physicians to dispense or pharmacists to prescribe certain drugs. In terms of total health care expenditures, we find no difference between the two systems, so we are doubtful that changing dispensing rights are a good measure to contain cost, at least in Switzerland.

  1. Video observation of hand hygiene practices during routine companion animal appointments and the effect of a poster intervention on hand hygiene compliance

    PubMed Central

    2014-01-01

    Background Hand hygiene is considered one of the most important infection control measures in human healthcare settings, but there is little information available regarding hand hygiene frequency and technique used in veterinary clinics. The objectives of this study were to describe hand hygiene practices associated with routine appointments in companion animal clinics in Ontario, and the effectiveness of a poster campaign to improve hand hygiene compliance. Results Observation of hand hygiene practices was performed in 51 clinics for approximately 3 weeks each using 2 small wireless surveillance cameras: one in an exam room, and one in the most likely location for hand hygiene to be performed outside the exam room following an appointment. Data from 38 clinics were included in the final analysis, including 449 individuals, 1139 appointments before and after the poster intervention, and 10894 hand hygiene opportunities. Overall hand hygiene compliance was 14% (1473/10894), while before and after patient contact compliance was 3% (123/4377) and 26% (1145/4377), respectively. Soap and water was used for 87% (1182/1353) of observed hand hygiene attempts with a mean contact time of 4 s (median 2 s, range 1-49 s), while alcohol-based hand rub (ABHR) was used for 7% (98/1353) of attempts with a mean contact time of 8 s (median 7 s, range 1-30 s). The presence of the posters had no significant effect on compliance, although some staff reported that they felt the posters did increase their personal awareness of the need to perform hand hygiene, and the posters had some effect on product contact times. Conclusions Overall hand hygiene compliance in veterinary clinics in this study was low, and contact time with hand hygiene products was frequently below current recommendations. Use of ABHR was low despite its advantages over hand washing and availability in the majority of clinics. The poster campaign had a limited effect on its own, but could still be used as a

  2. Video observation of hand hygiene practices during routine companion animal appointments and the effect of a poster intervention on hand hygiene compliance.

    PubMed

    Anderson, Maureen E C; Sargeant, Jan M; Weese, J Scott

    2014-05-07

    Hand hygiene is considered one of the most important infection control measures in human healthcare settings, but there is little information available regarding hand hygiene frequency and technique used in veterinary clinics. The objectives of this study were to describe hand hygiene practices associated with routine appointments in companion animal clinics in Ontario, and the effectiveness of a poster campaign to improve hand hygiene compliance. Observation of hand hygiene practices was performed in 51 clinics for approximately 3 weeks each using 2 small wireless surveillance cameras: one in an exam room, and one in the most likely location for hand hygiene to be performed outside the exam room following an appointment. Data from 38 clinics were included in the final analysis, including 449 individuals, 1139 appointments before and after the poster intervention, and 10894 hand hygiene opportunities. Overall hand hygiene compliance was 14% (1473/10894), while before and after patient contact compliance was 3% (123/4377) and 26% (1145/4377), respectively. Soap and water was used for 87% (1182/1353) of observed hand hygiene attempts with a mean contact time of 4 s (median 2 s, range 1-49 s), while alcohol-based hand rub (ABHR) was used for 7% (98/1353) of attempts with a mean contact time of 8 s (median 7 s, range 1-30 s). The presence of the posters had no significant effect on compliance, although some staff reported that they felt the posters did increase their personal awareness of the need to perform hand hygiene, and the posters had some effect on product contact times. Overall hand hygiene compliance in veterinary clinics in this study was low, and contact time with hand hygiene products was frequently below current recommendations. Use of ABHR was low despite its advantages over hand washing and availability in the majority of clinics. The poster campaign had a limited effect on its own, but could still be used as a component of a multimodal hand

  3. Comparison between Rinse and Crush-and-Rub Sampling for Aerobic Bacteria Recovery from Hatching Eggs after Sanitization

    USDA-ARS?s Scientific Manuscript database

    This study compared surface and deep eggshell aerobic bacteria recovered by rinse and crush-and-rub sampling methods for commercial hatching eggs after treatments with sanitizers. Eggs were arranged into 5 treatments consisting of three sanitizers, Water, and No-treatment. Sanitizers were Hydrogen...

  4. Gasoline on hands: preliminary study on collection and persistence.

    PubMed

    Darrer, Melinda; Jacquemet-Papilloud, Joëlle; Delémont, Olivier

    2008-03-05

    The identification of an arsonist remains one of the most difficult challenges a fire investigation has to face. Seeking and detection of traces of gasoline could provide a valuable information to link a suspect with an arson scene where gasoline was used to set-up the fire. In this perspective, a first study was undertaken to evaluate a simple, fast and efficient method for collecting gasoline from hands, and to assess its persistence over time. Four collection means were tested: PVC, PE and Latex gloves, as well as humidified filter paper. A statistical assessment of the results indicates that Latex and PVC gloves worn for about 20 min, as well as paper filter rubbed on hands, allow an efficient collection of gasoline applied to hands. Due to ease of manipulation and to a reduced amount of volatile compounds detected from the matrix, PVC gloves were selected for the second set of experiments. The evaluation of the persistence of gasoline on hands was then carried out using two initial quantities (500 and 1000 microl). Collection was made with PVC gloves after 0, 30 min, 1, 2 and 4h, on different volunteers. The results show a common tendency of massive evaporation of gasoline during the first 30 min: a continued but non-linear decrease was observed along different time intervals. The results of this preliminary study are in agreement with other previous researches conducted on the detection of flammable liquid residues on clothes, shoes and skin.

  5. Development of an observational measure of healthcare worker hand-hygiene behaviour: the hand-hygiene observation tool (HHOT).

    PubMed

    McAteer, J; Stone, S; Fuller, C; Charlett, A; Cookson, B; Slade, R; Michie, S

    2008-03-01

    Previous observational measures of healthcare worker (HCW) hand-hygiene behaviour (HHB) fail to provide adequate standard operating procedures (SOPs), accounts of inter-rater agreement testing or evidence of sensitivity to change. This study reports the development of an observational tool in a way that addresses these deficiencies. Observational categories were developed systematically, guided by a clinical guideline, previous measures and pilot hand-hygiene behaviour observations (HHOs). The measure, a simpler version of the Geneva tool, consists of HHOs (before and after low-risk, high-risk or unobserved contact), HHBs (soap, alcohol hand rub, no action, unknown), and type of HCW. Inter-observer agreement for each category was assessed by observation of 298 HHOs and HHBs by two independent observers on acute elderly and intensive care units. Raw agreement (%) and Kappa were 77% and 0.68 for HHB; 83% and 0.77 for HHO; and 90% and 0.77 for HCW. Inter-observer agreement for overall compliance of a group of HCWs was assessed by observation of 1191 HHOs and HHBs by two pairs of independent observers. Overall agreement was good (intraclass correlation coefficient = 0.79). Sensitivity to change was examined by autoregressive time-series modelling of longitudinal observations for 8 months on the intensive therapy unit during an Acinetobacter baumannii outbreak and subsequent strengthening of infection control measures. Sensitivity to change was demonstrated by a rise in compliance from 80 to 98% with an odds ratio of increased compliance of 7.00 (95% confidence interval: 4.02-12.2) P < 0.001.

  6. Impact of a multi-faceted training intervention on the improvement of hand hygiene and gloving practices in four healthcare settings including nursing homes, acute-care geriatric wards and physical rehabilitation units.

    PubMed

    Eveillard, Matthieu; Raymond, Françoise; Guilloteau, Véronique; Pradelle, Marie-Thérèse; Kempf, Marie; Zilli-Dewaele, Marina; Joly-Guillou, Marie-Laure; Brunel, Patrick

    2011-10-01

    To assess the impact of a multi-faceted training program on the compliance with hand hygiene and gloving practices. Hand hygiene is considered as the cornerstone of the prevention of hospital-acquired infections. Several studies have enhanced the poor effectiveness of training programs in improving hand hygiene compliance. A before-after evaluation study. The study was conducted in four healthcare settings before and after an intervention program which included the performance feedback of the first evaluation phase, three six-h training sessions, the assessment of hand hygiene performance with teaching boxes and the organisation of one full-day session devoted to institutional communication around hand hygiene in each setting. Hand hygiene compliance and quality of hand rubbing were evaluated. Hand hygiene opportunities were differentiated into extra-series opportunities (before or after a single contact and before the first contact or after the last contact of a series of consecutive contacts) and intra-series opportunities (from the opportunity following the first contact to the opportunity preceding the last in the same series). Overall, 969 contacts corresponding to 1,470 hand hygiene opportunities (760 during the first phase and 710 during the second) were observed. A significant improvement of observed practices was recorded for the hand hygiene compliance in intra-series opportunities (39·0% vs. 19·0%; p < 10(-5) ), the proportion of gloves worn if indicated (71·4% vs. 52·0%; p < 0·001) and the quality of hand rubbing (85·0% vs. 71·9%; p < 10(-5) ). Some of the performances measured for both hand hygiene and gloving practices were improved. We plan to extend this investigation by performing a qualitative study with experts in behavioural sciences to try improving practices for which adherence was still weak after the training program such as hand hygiene in intra-series opportunities. This study underscored the usefulness of implementing

  7. Optimizing Aerosol Dispensers for Mating Disruption of Codling Moth, Cydia pomonella L.

    PubMed

    McGhee, Peter S; Miller, James R; Thomson, Donald R; Gut, Larry J

    2016-07-01

    Experiments were conducted in commercial apple orchards to determine if improved efficiencies in pheromone delivery may be realized by using aerosol pheromone dispensers for codling moth (CM), Cydia pomonella L., mating disruption. Specifically, we tested how reducing: pheromone concentration, period of dispenser operation, and frequency of pheromone emission from aerosol dispensers affected orientational disruption of male CM to pheromone-baited monitoring traps. Isomate® CM MIST formulated with 50 % less codlemone (3.5 mg/ emission) provided orientation disruption equal to the standard commercial formulation (7 mg / emission). Decreased periods of dispenser operation (3 and 6 h) and frequency of pheromone emission (30 and 60 min) provided a level of orientational disruption similar to the current standard protocol of releasing pheromone over a 12 h period on a 15 min cycle, respectively. These three modifications provide a means of substantially reducing the amount of pheromone necessary for CM disruption. The savings accompanying pheromone conservation could lead to increased adoption of CM mating disruption and, moreover, provide an opportunity for achieving higher levels of disruption by increasing dispenser densities.

  8. Costing the Australian National Hand Hygiene Initiative.

    PubMed

    Page, K; Barnett, A G; Campbell, M; Brain, D; Martin, E; Fulop, N; Graves, N

    2014-11-01

    The Australian National Hand Hygiene Initiative (NHHI) is a major patient safety programme co-ordinated by Hand Hygiene Australia (HHA) and funded by the Australian Commission for Safety and Quality in Health Care. The annual costs of running this programme need to be understood to know the cost-effectiveness of a decision to sustain it as part of health services. To estimate the annual health services cost of running the NHHI; the set-up costs are excluded. A health services perspective was adopted for the costing and collected data from the 50 largest public hospitals in Australia that implemented the initiative, covering all states and territories. The costs of HHA, the costs to the state-level infection-prevention groups, the costs incurred by each acute hospital, and the costs for additional alcohol-based hand rub are all included. The programme cost AU$5.56 million each year (US$5.76, £3.63 million). Most of the cost is incurred at the hospital level (65%) and arose from the extra time taken for auditing hand hygiene compliance and doing education and training. On average, each infection control practitioner spent 5h per week on the NHHI, and the running cost per annum to their hospital was approximately AU$120,000 in 2012 (US$124,000, £78,000). Good estimates of the total costs of this programme are fundamental to understanding the cost-effectiveness of implementing the NHHI. This paper reports transparent costing methods, and the results include their uncertainty. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. Microwave-superheated Vics Vapo Rub: an ocular public health danger.

    PubMed

    Fung, Anne E; Oxford, Karen W

    2004-02-01

    To report a case of a microwave-oven superheated petroleum-based liquid causing severe chemical and thermal ocular burns treated successfully with amniotic membrane transplantation. Observational case report. Retrospective review of clinical case. A 77-year-old woman sustained a severe combined chemical and thermal burn from microwave-heated Vicks Vapo-Rub requiring amniotic membrane transplant, with subsequent development of phacomorphic glaucoma, requiring cataract extraction, and bullous keratopathy, requiring penetrating keratoplasty. As microwave oven use becomes more commonplace, the risk of superheating liquids becomes an increasingly significant ocular danger. Continued efforts to educate the public about safe microwave use is necessary. Additionally, amniotic membrane transplantation was found to be effective in managing a combined chemical and thermal ocular burn.

  10. Methods for dispensing mercury into devices

    DOEpatents

    Grossman, Mark W.; George, William A.

    1987-04-28

    A process for dispensing mercury into devices which requires mercury. Mercury is first electrolytically separated from either HgO or Hg.sub.2 Cl.sub.2 and plated onto a cathode wire. The cathode wire is then placed into a device requiring mercury.

  11. Hand hygiene in the intensive care unit.

    PubMed

    Tschudin-Sutter, Sarah; Pargger, Hans; Widmer, Andreas F

    2010-08-01

    Healthcare-associated infections affect 1.4 million patients at any time worldwide, as estimated by the World Health Organization. In intensive care units, the burden of healthcare-associated infections is greatly increased, causing additional morbidity and mortality. Multidrug-resistant pathogens are commonly involved in such infections and render effective treatment challenging. Proper hand hygiene is the single most important, simplest, and least expensive means of preventing healthcare-associated infections. In addition, it is equally important to stop transmission of multidrug-resistant pathogens. According to the Centers for Disease Control and Prevention and World Health Organization guidelines on hand hygiene in health care, alcohol-based handrub should be used as the preferred means for routine hand antisepsis. Alcohols have excellent in vitro activity against Gram-positive and Gram-negative bacteria, including multidrug-resistant pathogens, such as methicillin-resistant Staphylococcus aureus and vancomycin-resistant enterococci, Mycobacterium tuberculosis, a variety of fungi, and most viruses. Some pathogens, however, such as Clostridium difficile, Bacillus anthracis, and noroviruses, may require special hand hygiene measures. Failure to provide user friendliness of hand hygiene equipment and shortage of staff are predictors for noncompliance, especially in the intensive care unit setting. Therefore, practical approaches to promote hand hygiene in the intensive care unit include provision of a minimal number of handrub dispensers per bed, monitoring of compliance, and choice of the most attractive product. Lack of knowledge of guidelines for hand hygiene, lack of recognition of hand hygiene opportunities during patient care, and lack of awareness of the risk of cross-transmission of pathogens are barriers to good hand hygiene practices. Multidisciplinary programs to promote increased use of alcoholic handrub lead to an increased compliance of healthcare

  12. 48 CFR 52.237-11 - Accepting and Dispensing of $1 Coin.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of $1 Coin. 52.237-11 Section 52.237-11 Federal Acquisition Regulations System FEDERAL ACQUISITION... Clauses 52.237-11 Accepting and Dispensing of $1 Coin. As prescribed in 37.116-2, insert the following clause: Accepting and Dispensing of $1 Coin (SEP 2008) (a) This clause applies to service contracts that...

  13. 48 CFR 52.237-11 - Accepting and Dispensing of $1 Coin.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of $1 Coin. 52.237-11 Section 52.237-11 Federal Acquisition Regulations System FEDERAL ACQUISITION... Clauses 52.237-11 Accepting and Dispensing of $1 Coin. As prescribed in 37.116-2, insert the following clause: Accepting and Dispensing of $1 Coin (SEP 2008) (a) This clause applies to service contracts that...

  14. Towards more reliable automated multi-dose dispensing: retrospective follow-up study on medication dose errors and product defects.

    PubMed

    Palttala, Iida; Heinämäki, Jyrki; Honkanen, Outi; Suominen, Risto; Antikainen, Osmo; Hirvonen, Jouni; Yliruusi, Jouko

    2013-03-01

    To date, little is known on applicability of different types of pharmaceutical dosage forms in an automated high-speed multi-dose dispensing process. The purpose of the present study was to identify and further investigate various process-induced and/or product-related limitations associated with multi-dose dispensing process. The rates of product defects and dose dispensing errors in automated multi-dose dispensing were retrospectively investigated during a 6-months follow-up period. The study was based on the analysis of process data of totally nine automated high-speed multi-dose dispensing systems. Special attention was paid to the dependence of multi-dose dispensing errors/product defects and pharmaceutical tablet properties (such as shape, dimensions, weight, scored lines, coatings, etc.) to profile the most suitable forms of tablets for automated dose dispensing systems. The relationship between the risk of errors in dose dispensing and tablet characteristics were visualized by creating a principal component analysis (PCA) model for the outcome of dispensed tablets. The two most common process-induced failures identified in the multi-dose dispensing are predisposal of tablet defects and unexpected product transitions in the medication cassette (dose dispensing error). The tablet defects are product-dependent failures, while the tablet transitions are dependent on automated multi-dose dispensing systems used. The occurrence of tablet defects is approximately twice as common as tablet transitions. Optimal tablet preparation for the high-speed multi-dose dispensing would be a round-shaped, relatively small/middle-sized, film-coated tablet without any scored line. Commercial tablet products can be profiled and classified based on their suitability to a high-speed multi-dose dispensing process.

  15. Design and Fabrication of a MEMS Flow Sensor and Its Application in Precise Liquid Dispensing

    PubMed Central

    Liu, Yaxin; Chen, Liguo; Sun, Lining

    2009-01-01

    A high speed MEMS flow sensor to enhance the reliability and accuracy of a liquid dispensing system is proposed. Benefitting from the sensor information feedback, the system can self-adjust the open time of the solenoid valve to accurately dispense desired volumes of reagent without any pre-calibration. First, an integrated high-speed liquid flow sensor based on the measurement of the pressure difference across a flow channel is presented. Dimensions of the micro-flow channel and two pressure sensors have been appropriately designed to meet the static and dynamic requirements of the liquid dispensing system. Experiments results show that the full scale (FS) flow measurement ranges up to 80 μL/s, with a nonlinearity better than 0.51% FS. Secondly, a novel closed-loop control strategy is proposed to calculate the valve open time in each dispensing cycle, which makes the system immune to liquid viscosity, pressure fluctuation, and other sources of error. Finally, dispensing results show that the system can achieve better dispensing performance, and the coefficient of variance (CV) for liquid dispensing is below 3% at 1 μL and below 4% at 100 nL. PMID:22408517

  16. Design and Fabrication of a MEMS Flow Sensor and Its Application in Precise Liquid Dispensing.

    PubMed

    Liu, Yaxin; Chen, Liguo; Sun, Lining

    2009-01-01

    A high speed MEMS flow sensor to enhance the reliability and accuracy of a liquid dispensing system is proposed. Benefitting from the sensor information feedback, the system can self-adjust the open time of the solenoid valve to accurately dispense desired volumes of reagent without any pre-calibration. First, an integrated high-speed liquid flow sensor based on the measurement of the pressure difference across a flow channel is presented. Dimensions of the micro-flow channel and two pressure sensors have been appropriately designed to meet the static and dynamic requirements of the liquid dispensing system. Experiments results show that the full scale (FS) flow measurement ranges up to 80 μL/s, with a nonlinearity better than 0.51% FS. Secondly, a novel closed-loop control strategy is proposed to calculate the valve open time in each dispensing cycle, which makes the system immune to liquid viscosity, pressure fluctuation, and other sources of error. Finally, dispensing results show that the system can achieve better dispensing performance, and the coefficient of variance (CV) for liquid dispensing is below 3% at 1 μL and below 4% at 100 nL.

  17. Automated drug dispensing system reduces medication errors in an intensive care setting.

    PubMed

    Chapuis, Claire; Roustit, Matthieu; Bal, Gaëlle; Schwebel, Carole; Pansu, Pascal; David-Tchouda, Sandra; Foroni, Luc; Calop, Jean; Timsit, Jean-François; Allenet, Benoît; Bosson, Jean-Luc; Bedouch, Pierrick

    2010-12-01

    We aimed to assess the impact of an automated dispensing system on the incidence of medication errors related to picking, preparation, and administration of drugs in a medical intensive care unit. We also evaluated the clinical significance of such errors and user satisfaction. Preintervention and postintervention study involving a control and an intervention medical intensive care unit. Two medical intensive care units in the same department of a 2,000-bed university hospital. Adult medical intensive care patients. After a 2-month observation period, we implemented an automated dispensing system in one of the units (study unit) chosen randomly, with the other unit being the control. The overall error rate was expressed as a percentage of total opportunities for error. The severity of errors was classified according to National Coordinating Council for Medication Error Reporting and Prevention categories by an expert committee. User satisfaction was assessed through self-administered questionnaires completed by nurses. A total of 1,476 medications for 115 patients were observed. After automated dispensing system implementation, we observed a reduced percentage of total opportunities for error in the study compared to the control unit (13.5% and 18.6%, respectively; p<.05); however, no significant difference was observed before automated dispensing system implementation (20.4% and 19.3%, respectively; not significant). Before-and-after comparisons in the study unit also showed a significantly reduced percentage of total opportunities for error (20.4% and 13.5%; p<.01). An analysis of detailed opportunities for error showed a significant impact of the automated dispensing system in reducing preparation errors (p<.05). Most errors caused no harm (National Coordinating Council for Medication Error Reporting and Prevention category C). The automated dispensing system did not reduce errors causing harm. Finally, the mean for working conditions improved from 1.0±0.8 to 2

  18. Ultrasound aided smooth dispensing for high viscoelastic epoxy in microelectronic packaging.

    PubMed

    Chen, Yun; Li, Han-Xiong; Shan, Xiuyang; Gao, Jian; Chen, Xin; Wang, Fuliang

    2016-01-01

    Epoxy dispensing is one of the most critical processes in microelectronic packaging. However, due its high viscoelasticity, dispensing of epoxy is extremely difficult, and a lower viscoelasticity epoxy is desired to improve the process. In this paper, a novel method is proposed to achieve a lowered viscoelastic epoxy by using ultrasound. The viscoelasticity and molecular structures of the epoxies were compared and analyzed before and after experimentation. Different factors of the ultrasonic process, including power, processing time and ultrasonic energy, were studied in this study. It is found that elasticity is more sensitive to ultrasonic processing while viscosity is little affected. Further, large power and long processing time can minimize the viscoelasticity to ideal values. Due to the reduced loss modulus and storage modulus after ultrasonic processing, smooth dispensing is demonstrated for the processed epoxy. The subsequently color temperature experiments show that ultrasonic processing will not affect LED's lighting. It is clear that the ultrasonic processing will have good potential to aide smooth dispensing for high viscoelastic epoxy in electronic industry. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. International Space Station USOS Potable Water Dispenser Development

    NASA Technical Reports Server (NTRS)

    Shaw, Laura A.; Barreda, Jose L.

    2008-01-01

    The International Space Station (ISS) Russian Segment currently provides potable water dispensing capability for crewmember food and beverage rehydration. All ISS crewmembers rehydrate Russian and U.S. style food packages from this location. A new United States On-orbit Segment (USOS) Potable Water Dispenser (PWD) is under development. This unit will provide additional potable water dispensing capability to support an onorbit crew of six. The PWD is designed to provide incremental quantities of hot and ambient temperature potable water to U.S. style food packages. It will receive iodinated water from the Fuel Cell Water Bus in the U.S. Laboratory element. The unit will provide potable-quality water, including active removal of biocidal iodine prior to dispensing. A heater assembly contained within the unit will be able to supply up to 2.0 liters of hot water (65 to 93oC) every thirty minutes. This quantity will allow three to four crewmembers to rehydrate their food and beverages from this location during a single meal. The unit is designed to remain functional for up to ten years with replacement of limited life items such as filters. It will be the size of two stacked Shuttle Middeck lockers (approximately the size of two small suitcases) and integrated into a science payload rack in the U.S. Laboratory element. Providing potable-quality water at the proper temperature for food and beverage reconstitution is critical to maintaining crew health and well-being. The numerous engineering challenges as well as human factors and safety considerations during the concept, design, and prototyping are outlined in this paper.

  20. An automatic pellet dispenser for precise control of feeding topography in granivorous birds

    PubMed Central

    Berkhoudt, H.; Van Der Reijden, D.; Heijmans, M.

    1987-01-01

    Design and construction of an automatic pellet dispenser for granivorous birds are described. The dispenser permits rapid pneumatic delivery of pellets (five pellets per second maximum) to one controlled position and does not interfere with simultaneous electrophysiological recording. In addition, the device continuously indicates presence or absence of a pellet in the delivery position. This automatic dispenser proved very effective in our studies of stereotyped topographies of feeding in granivorous birds, such as pigeons and chickens. PMID:16812503

  1. Implementation and evaluation of an automated dispensing system.

    PubMed

    Schwarz, H O; Brodowy, B A

    1995-04-15

    An institution's experience in replacing a traditional unit dose cassette-exchange system with an automated dispensing system is described. A 24-hour unit dose cassette-exchange system was replaced with an automated dispensing system (Pyxis's Medstation Rx) on a 36-bed cardiovascular surgery unit and an 8-bed cardiovascular intensive care unit. Significantly fewer missing doses were reported after Medstation Rx was implemented. No conclusions could be made about the impact of the system on the reporting of medication errors. The time savings for pharmacy associated with the filling, checking, and delivery of new medication orders equated to about 0.5 full-time equivalent (FTE). Medstation Rx also saved substantial nursing time for acquisition of controlled substances and for controlled-substance inventory taking at shift changes. A financial analysis showed that Medstation Rx could save the institution about $1 million over five years if all personnel time savings could be translated into FTE reductions. The automated system was given high marks by the nurses in a survey; 80% wanted to keep the system on their unit. Pilot implementation of an automated dispensing system improved the efficiency of drug distribution over that of the traditional unit dose cassette-exchange system.

  2. Analysis of alcohol-based hand sanitizer delivery systems: efficacy of foam, gel, and wipes against influenza A (H1N1) virus on hands.

    PubMed

    Larson, Elaine L; Cohen, Bevin; Baxter, Kathleen A

    2012-11-01

    Minimal research has been published evaluating the effectiveness of hand hygiene delivery systems (ie, rubs, foams, or wipes) at removing viruses from hands. The purposes of this study were to determine the effect of several alcohol-based hand sanitizers in removing influenza A (H1N1) virus, and to compare the effectiveness of foam, gel, and hand wipe products. Hands of 30 volunteers were inoculated with H1N1 and randomized to treatment with foam, gel, or hand wipe applied to half of each volunteer's finger pads. The log(10) count of each subject's treated and untreated finger pads were averaged. Log(10) reductions were calculated from these differences and averaged within treatment group. Between-treatment analysis compared changes from the untreated finger pads using analysis of covariance with treatment as a factor and the average log(10) untreated finger pads as the covariate. Log(10) counts on control finger pads were 2.7-5.3 log(10) of the 50% infectious dose for tissue culture (TCID(50)/0.1 mL) (mean, 3.8 ± 0.5 log(10) TCID(50)/0.1 mL), and treated finger pad counts for all test products were 0.5-1.9 log(10) TCID(50)/0.1 mL (mean, 0.53 ± 0.17 log(10) TCID(50)/0.1 mL). Treatments with all products resulted in a significant reduction in viral titers (>3 logs) at their respective exposure times that were statistically comparable. All 3 delivery systems (foam, gel, and wipe) produced significantly reduced viral counts on hands. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  3. Evaluating dispensers loaded with codlemone and pear ester for disruption of codling moth (Lepidoptera: Tortricidae)

    USDA-ARS?s Scientific Manuscript database

    Polyvinyl chloride polymer (pvc) dispensers loaded with ethyl (E,Z)-2,4-decadienoate (pear ester) plus the sex pheromone, (E,E)-8,10-dodecadien-1-ol (codlemone) of codling moth, Cydia pomonella (L.), were compared with similar dispensers and a commercial dispenser (Isomate®-C Plus) loaded with codle...

  4. Point of care hand hygiene-where's the rub? A survey of US and Canadian health care workers' knowledge, attitudes, and practices.

    PubMed

    Kirk, Jane; Kendall, Anson; Marx, James F; Pincock, Ted; Young, Elizabeth; Hughes, Jillian M; Landers, Timothy

    2016-10-01

    Hand hygiene at the point of care is recognized as a best practice for promoting compliance at the moments when hand hygiene is most critical. The objective of this study was to compare knowledge, attitudes, and practices of US and Canadian frontline health care personnel regarding hand hygiene at the point of care. Physicians and nurses in US and Canadian hospitals were invited to complete a 32-question online survey based on evidence supporting point of care hand hygiene. Eligible health care personnel were in direct clinical practice at least 50% of the time. Three hundred fifty frontline caregivers completed the survey. Among respondents, 57.1% were from the United States and 42.9% were from Canada. Respondents were evenly distributed between physician and nurses. The US and Canadian respondents gave identical ranking to their perceived barriers to hand hygiene compliance. More than half of the respondents from both the United States and Canada agreed or strongly agreed that they would be more likely to clean their hands when recommended if alcohol-based handrub was closer to the patient. This survey demonstrates that similarities between Canada and the United States were more common than not, and the survey raises, or suggests, potential knowledge gaps that require further illumination. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  5. Association of emergency department albuterol dispensing with pediatric asthma revisits and readmissions.

    PubMed

    Hall, A Brad; Novotny, April; Bhisitkul, Donna M; Melton, James; Regan, Tim; Leckie, Maureen

    2017-06-01

    Although pediatric asthma continues to be a highly studied disease, data to suggest clear strategies to decrease asthma related revisits or readmissions is lacking. The purpose of our study was to assess the effect of emergency department (ED) direct dispensing of beta-agonist metered dose inhalers on pediatric asthma ED revisit and readmission rates. We conducted a retrospective cohort study of pediatric patients discharged from the pediatric ED with a diagnosis of asthma. Our primary outcome measured the rate of asthma revisits to the ED or admissions to the hospital within 28 days. Logistic regression analysis was used to assess ED beta-agonist MDI dispensing and revisit and/or readmission as the outcome. A total of 853 patients met eligibility for inclusion in the study, with 657 enrolled in the Baseline group and 196 enrolled in the ED-MDI group. The Baseline group experienced a revisit and readmission rate of 7.0% (46/657) versus 2.6% (5/196) in the ED-MDI group, (p = 0.026). ED direct dispensing of MDIs was found to be independently associated with a decreased risk of revisit or readmission (odds ratio 0.37; 95% confidence interval 0.14-0.95). In our study, ED direct dispensing of beta-agonist MDIs resulted in a reduction in 28-day revisit and readmission to the hospital. Further studies should be performed to evaluate the economic impact of reducing these revisits and readmissions against the costs of maintaining a dispensing program. Our findings may support modification of asthma programs to include dispensing MDIs from the emergency department.

  6. ARAS: an automated radioactivity aliquoting system for dispensing solutions containing positron-emitting radioisotopes

    DOE PAGES

    Dooraghi, Alex A.; Carroll, Lewis; Collins, Jeffrey; ...

    2016-03-09

    Automated protocols for measuring and dispensing solutions containing radioisotopes are essential not only for providing a safe environment for radiation workers but also to ensure accuracy of dispensed radioactivity and an efficient workflow. For this purpose, we have designed ARAS, an automated radioactivity aliquoting system for dispensing solutions containing positron-emitting radioisotopes with particular focus on fluorine-18 (18F). The key to the system is the combination of a radiation detector measuring radioactivity concentration, in line with a peristaltic pump dispensing known volumes. Results show the combined system demonstrates volume variation to be within 5 % for dispensing volumes of 20 μLmore » or greater. When considering volumes of 20 μL or greater, the delivered radioactivity is in agreement with the requested amount as measured independently with a dose calibrator to within 2 % on average. In conclusion, the integration of the detector and pump in an in-line system leads to a flexible and compact approach that can accurately dispense solutions containing radioactivity concentrations ranging from the high values typical of [18F]fluoride directly produced from a cyclotron (~0.1-1 mCi μL -1) to the low values typical of batches of [18F]fluoride-labeled radiotracers intended for preclinical mouse scans (~1-10 μCi μL -1).« less

  7. Hand hygiene and healthcare system change within multi-modal promotion: a narrative review.

    PubMed

    Allegranzi, B; Sax, H; Pittet, D

    2013-02-01

    Many factors may influence the level of compliance with hand hygiene recommendations by healthcare workers. Lack of products and facilities as well as their inappropriate and non-ergonomic location represent important barriers. Targeted actions aimed at making hand hygiene practices feasible during healthcare delivery by ensuring that the necessary infrastructure is in place, defined as 'system change', are essential to improve hand hygiene in healthcare. In particular, access to alcohol-based hand rubs (AHRs) enables appropriate and timely hand hygiene performance at the point of care. The feasibility and impact of system change within multi-modal strategies have been demonstrated both at institutional level and on a large scale. The introduction of AHRs overcomes some important barriers to best hand hygiene practices and is associated with higher compliance, especially when integrated within multi-modal strategies. Several studies demonstrated the association between AHR consumption and reduction in healthcare-associated infection, in particular, meticillin-resistant Staphylococcus aureus bacteraemia. Recent reports demonstrate the feasibility and success of system change implementation on a large scale. The World Health Organization and other investigators have reported the challenges and encouraging results of implementing hand hygiene improvement strategies, including AHR introduction, in settings with limited resources. This review summarizes the available evidence demonstrating the need for system change and its importance within multi-modal hand hygiene improvement strategies. This topic is also discussed in a global perspective and highlights some controversial issues. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  8. Methods for dispensing mercury into devices

    DOEpatents

    Grossman, M.W.; George, W.A.

    1987-04-28

    A process is described for dispensing mercury into devices which requires mercury. Mercury is first electrolytically separated from either HgO or Hg[sub 2]Cl[sub 2] and plated onto a cathode wire. The cathode wire is then placed into a device requiring mercury. 2 figs.

  9. Single crystalline growth of a soluble organic semiconductor in a parallel aligned liquid crystal solvent using rubbing-treated polyimide films

    NASA Astrophysics Data System (ADS)

    Matsuzaki, Tomoya; Shibata, Yosei; Takeda, Risa; Ishinabe, Takahiro; Fujikake, Hideo

    2017-01-01

    For directional control of organic single crystals, we propose a crystal growth method using liquid crystal as the solvent. In this study, we examined the formation of 2,7-dioctyl[1]benzothieno[3,2-b][1]benzothiophene (C8-BTBT) single crystals using a parallel aligned liquid crystal (LC) cell and rubbing-treated polyimide films in order to clarify the effects of LC alignment on anisotropic C8-BTBT crystal growth. Based on the results, we found that the crystal growth direction of C8-BTBT single crystals was related to the direction of the aligned LC molecules because of rubbing treatment. Moreover, by optical evaluation, we found that the C8-BTBT single crystals have a aligned molecular structure.

  10. Changing the paradigm: messages for hand hygiene education and audit from cluster analysis.

    PubMed

    Gould, D J; Navaie, D; Purssell, E; Drey, N S; Creedon, S

    2018-04-01

    Hand hygiene is considered to be the foremost infection prevention measure. How healthcare workers accept and make sense of the hand hygiene message is likely to contribute to the success and sustainability of initiatives to improve performance, which is often poor. A survey of nurses in critical care units in three National Health Service trusts in England was undertaken to explore opinions about hand hygiene, use of alcohol hand rubs, audit with performance feedback, and other key hand-hygiene-related issues. Data were analysed descriptively and subjected to cluster analysis. Three main clusters of opinion were visualized, each forming a significant group: positive attitudes, pragmatism and scepticism. A smaller cluster suggested possible guilt about ability to perform hand hygiene. Cluster analysis identified previously unsuspected constellations of beliefs about hand hygiene that offer a plausible explanation for behaviour. Healthcare workers might respond to education and audit differently according to these beliefs. Those holding predominantly positive opinions might comply with hand hygiene policy and perform well as infection prevention link nurses and champions. Those holding pragmatic attitudes are likely to respond favourably to the need for professional behaviour and need to protect themselves from infection. Greater persuasion may be needed to encourage those who are sceptical about the importance of hand hygiene to comply with guidelines. Interventions to increase compliance should be sufficiently broad in scope to tackle different beliefs. Alternatively, cluster analysis of hand hygiene beliefs could be used to identify the most effective educational and monitoring strategies for a particular clinical setting. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  11. Comparison between rinse and crush-and-rub sampling for aerobic bacteria recovery from broiler hatching eggs after sanitization

    USDA-ARS?s Scientific Manuscript database

    This study compared surface and deep eggshell aerobic bacteria recovered by rinse and crush-and-rub sampling methods for commercial hatching eggs after treatment with sanitizers. Eggs were arranged into 5 treatments consisting of No-treatment, Water, and three sanitizers. Sanitizers were Hydrogen ...

  12. Dispensing Equipment Testing with Mid-Level Ethanol/Gasoline Test Fluid: Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyce, K.; Chapin, J. T.

    The National Renewable Energy Laboratory's (NREL) Nonpetroleum-Based Fuel Task addresses the hurdles to commercialization of biomass-derived fuels and fuel blends. One such hurdle is the unknown compatibility of new fuels with current infrastructure, such as the equipment used at service stations to dispense fuel into automobiles. The U.S. Department of Energy's (DOE) Vehicle Technology Program and the Biomass Program have engaged in a joint project to evaluate the potential for blending ethanol into gasoline at levels higher than nominal 10 volume percent. This project was established to help DOE and NREL better understand any potentially adverse impacts caused by amore » lack of knowledge about the compatibility of the dispensing equipment with ethanol blends higher than what the equipment was designed to dispense. This report provides data about the impact of introducing a gasoline with a higher volumetric ethanol content into service station dispensing equipment from a safety and a performance perspective.« less

  13. Comparison of the antibacterial efficacy and acceptability of an alcohol-based hand rinse with two alcohol-based hand gels during routine patient care.

    PubMed

    Barbut, Frédéric; Maury, Eric; Goldwirt, Laurianne; Boëlle, Piérre-Yves; Neyme, Denis; Aman, Rubina; Rossi, Beatrice; Offenstadt, Georges

    2007-06-01

    The aims of this study were to compare the antibacterial efficacy of handrubbing with an alcoholic rinse (AHRR) and two different alcoholic gels (AHRG) in reducing hand contamination under practical use conditions. We wanted to assess the acceptability of the three products and to determine the effect of each product on overall hand hygiene compliance. A prospective alternating time-series clinical trial was performed in a medical intensive care unit. The study was divided into three six-week periods (P1, P2, P3). Handrubbing was achieved with Sterillium rinse (AHRR) during P1, sterillium gel(AHRG-1) during P2 and Manugel Plus (AHRG-2) during P3. Pre- and post-rubbing hand contaminations were assessed immediately after a direct contact with a patient, using the glove juice technique. Health care workers (HCWs) evaluated the acceptability of the products through a self-administered anonymous questionnaire. Compliance of HCWs with hand hygiene was assessed during the three periods. We studied 242 handrubbing opportunities. The mean reduction factor (expressed as the Log(10) CFU/mL) of the AHRR, AHRG-1 and AHRG-2 were 1.28+/-0.95, 1.29+/-0.84 and 0.51+/-0.73, respectively (p<0.001). Assessment of the three products by HCWs indicated that AHRR and AHRG-1 were significantly better accepted than AHRG-2. The overall compliance of HCWs to hand hygiene was better when gel was available. Under practical use conditions, AHRG-1 and AHRR were more effective than AHRG-2, although all were claimed to pass the European standard EN1500. In vivo trials are essential to compare the antimicrobial efficacy of products for handrubbing.

  14. Hand Hygiene Improvement and Sustainability: Assessing a Breakthrough Collaborative in Western Switzerland.

    PubMed

    Staines, Anthony; Amherdt, Isabelle; Lécureux, Estelle; Petignat, Christiane; Eggimann, Philippe; Schwab, Marcos; Pittet, Didier

    2017-12-01

    OBJECTIVE To assess hand hygiene improvement and sustainability associated with a Breakthrough Collaborative. DESIGN Multicenter analysis of hand hygiene compliance through direct observation by trained observers. SETTING A total of 5 publicly funded hospitals in 14 locations, with a total of 1,152 beds, in the County of Vaud, Switzerland. PARTICIPANTS Clinical staff. INTERVENTIONS In total, 59,272 opportunities for hand hygiene were monitored for the duration of the study, for an average of 5,921 per audit (range, 5,449-6,852). An 18-month Hand Hygiene Breakthrough Collaborative was conducted to implement the WHO multimodal promotional strategy including improved access to alcohol-based hand rub, education, performance measurement and feedback, reminders and communication, leadership engagement, and safety culture. RESULTS Overall hand hygiene compliance improved from 61.9% to 88.3% (P<.001) over 18 months and was sustained at 88.9% (P=.248) 12 months after the intervention. Hand hygiene compliance among physicians increased from 62% to 85% (P<.001) and finally 86% at follow-up (P=.492); for nursing staff, compliance improved from 64% to 90% (P<.001) and finally 90% at follow-up (P=.464); for physiotherapists compliance improved from 50% to 90% (P<.001) and finally 91% at follow-up (P=.619); for X-ray technicians compliance improved from 45% to 80% (P<.001) and finally 81% at follow-up (P=.686). Hand hygiene compliance also significantly increased with sustained improvement across all hand hygiene indications and all hospitals. CONCLUSIONS A rigorously conducted multicenter project combining the Breakthrough Collaborative method for its structure and the WHO multimodal strategy for content and measurement was associated with significant and substantial improvement in compliance across all professions, all hand hygiene indications, and all participating hospitals. Infect Control Hosp Epidemiol 2017;38:1420-1427.

  15. Automatic water inventory, collecting, and dispensing unit

    NASA Technical Reports Server (NTRS)

    Hall, J. B., Jr.; Williams, E. F.

    1972-01-01

    Two cylindrical tanks with piston bladders and associated components for automatic filling and emptying use liquid inventory readout devices in control of water flow. Unit provides for adaptive water collection, storage, and dispensation in weightlessness environment.

  16. Adverse selection? A multi-dimensional profile of people dispensed opioid analgesics for persistent non-cancer pain.

    PubMed

    Rogers, Kris D; Kemp, Anna; McLachlan, Andrew J; Blyth, Fiona

    2013-01-01

    This study investigates utilisation patterns for prescription opioid analgesics in the Australian community and how these are associated with a framework of individual-level factors related to healthcare use. Self-reported demographic and health information from participants in the 45 and Up Study cohort were linked to pharmaceutical claims from 2006-2009. Participants comprised 19,816 people with ≥1 opioid analgesic dispensing in the 12-months after recruitment to the cohort and 79,882 people not dispensed opioid analgesics. All participants were aged ≥45 years, were social security pharmaceutical beneficiaries, with no history of cancer. People dispensed opioid analgesics were classified as having acute (dispensing period <90 days), episodic (≥90 days and <3 'authority' prescriptions for increased quantity supply) or long-term treatment (≥90 days and ≥3 authority prescriptions). Of participants dispensed opioid analgesic 52% received acute treatment, 25% episodic treatment and 23% long-term treatment. People dispensed opioid analgesics long-term had an average of 14.9 opioid analgesic prescriptions/year from 2.0 doctors compared with 1.5 prescriptions from 1.1 doctors for people receiving acute treatment. People dispensed opioid analgesics reported more need-related factors such as poorer physical functioning and higher psychological distress. Long-term users were more likely to have access-related factors such as low-income and living outside major cities. After simultaneous adjustment, association with predisposing health factors and access diminished, but indicators of need such as osteoarthritis treatment, paracetamol use, and poor physical function were the strongest predictors for all opioid analgesic users. People dispensed opioid analgesics were in poorer health, reported higher levels of distress and poorer functioning than people not receiving opioid analgesics. Varying dispensing profiles were evident among people dispensed opioid analgesics

  17. Adverse Selection? A Multi-Dimensional Profile of People Dispensed Opioid Analgesics for Persistent Non-Cancer Pain

    PubMed Central

    Rogers, Kris D.; Kemp, Anna; McLachlan, Andrew J.; Blyth, Fiona

    2013-01-01

    Objectives This study investigates utilisation patterns for prescription opioid analgesics in the Australian community and how these are associated with a framework of individual-level factors related to healthcare use. Methods Self-reported demographic and health information from participants in the 45 and Up Study cohort were linked to pharmaceutical claims from 2006–2009. Participants comprised 19,816 people with ≥1 opioid analgesic dispensing in the 12-months after recruitment to the cohort and 79,882 people not dispensed opioid analgesics. All participants were aged ≥45 years, were social security pharmaceutical beneficiaries, with no history of cancer. People dispensed opioid analgesics were classified as having acute (dispensing period <90 days), episodic (≥90 days and <3 ‘authority’ prescriptions for increased quantity supply) or long-term treatment (≥90 days and ≥3 authority prescriptions). Results Of participants dispensed opioid analgesic 52% received acute treatment, 25% episodic treatment and 23% long-term treatment. People dispensed opioid analgesics long-term had an average of 14.9 opioid analgesic prescriptions/year from 2.0 doctors compared with 1.5 prescriptions from 1.1 doctors for people receiving acute treatment. People dispensed opioid analgesics reported more need-related factors such as poorer physical functioning and higher psychological distress. Long-term users were more likely to have access-related factors such as low-income and living outside major cities. After simultaneous adjustment, association with predisposing health factors and access diminished, but indicators of need such as osteoarthritis treatment, paracetamol use, and poor physical function were the strongest predictors for all opioid analgesic users. Conclusions People dispensed opioid analgesics were in poorer health, reported higher levels of distress and poorer functioning than people not receiving opioid analgesics. Varying dispensing profiles were

  18. Numerical Simulation Analysis of High-precision Dispensing Needles for Solid-liquid Two-phase Grinding

    NASA Astrophysics Data System (ADS)

    Li, Junye; Hu, Jinglei; Wang, Binyu; Sheng, Liang; Zhang, Xinming

    2018-03-01

    In order to investigate the effect of abrasive flow polishing surface variable diameter pipe parts, with high precision dispensing needles as the research object, the numerical simulation of the process of polishing high precision dispensing needle was carried out. Analysis of different volume fraction conditions, the distribution of the dynamic pressure and the turbulence viscosity of the abrasive flow field in the high precision dispensing needle, through comparative analysis, the effectiveness of the abrasive grain polishing high precision dispensing needle was studied, controlling the volume fraction of silicon carbide can change the viscosity characteristics of the abrasive flow during the polishing process, so that the polishing quality of the abrasive grains can be controlled.

  19. Dispensing with conscience: a legal and ethical assessment.

    PubMed

    Wernow, Jerome R; Grant, Donald G

    2008-11-01

    For over 30 years, pharmacists have exercised the right to dispense medications in accordance with moral convictions based upon a Judeo-Christian ethic. What many of these practitioners see as an apparent shift away from this time-honored ethic has resulted in a challenge to this right. To review and analyze pharmacy practice standards, legal proceedings, and ethical principles behind conflicts of conscientious objection in dispensing drugs used for emergency contraception. We first searched the terms conscience and clause and Plan B and contraception and abortion using Google, Yahoo, and Microsoft Networks (2006-September 26, 2008). Second, we used Medscape to search professional pharmacy and other medical journals, restricting our terms to conscience, Plan B, contraceptives, and abortifacients. Finally, we employed Loislaw, an online legal archiving service, and did a global search on the phrase conscience clause to determine the status of the legal discussion. To date, conflicts in conscientious objection have arisen when a pharmacist believes that dispensing an oral contraceptive violates his or her moral understanding for the promotion of human life. Up to this time, cases in pharmacy have involved only practitioners from orthodox Christian faith communities, primarily devout Roman Catholics. A pharmacist's right to refuse the dispensing of abortifacients for birth control according to moral conscience over against a woman's right to reproductive birth control has created a conflict that has yet to be reconciled by licensing agents, professional standards, or courts of law. Our analysis of prominent conflicts suggests that the underlying worldviews between factions make compromise improbable. Risks and liabilities are dependent upon compliance with evolving state laws, specific disclosure of a pharmacist's moral objections, and professionalism in the handling of volatile situations. Objecting pharmacists and their employers should have clear policies and

  20. Spectacle dispensing in Timor-Leste: tiered-pricing, cross-subsidization and financial viability.

    PubMed

    Ramke, Jacqueline; Brian, Garry; Palagyi, Anna

    2012-08-01

    To examine the financial viability of the Timor-Leste National Spectacle Program as it increases spectacle availability, affordability and uptake, particularly for Timor's poor. In rural areas, three models of ready-made spectacles were dispensed according to a tiered pricing structure of US$3.00, 1.00, 0.10 and 0.00. In addition, custom-made spectacles were available in the capital, Dili. Spectacle costs, dispensing data and income for the National Spectacle Program for 18 months from March 2007 were analyzed. Rural services dispensed 3415 readymade spectacles: 47.1% to women, and 51.4% at subsidized prices, being 39.8% at US$0.10 and 11.6% free. A profit of US$1,529 was generated, mainly from the sale of US$3.00 spectacles. Women (odds ratio, OR, 1.3, 95% confidence interval, CI, 1.1-1.4) and consumers aged ≥65 years (OR 2.1; 95% CI 1.7-2.6) were more likely to receive subsidized spectacles. Urban services dispensed 2768 spectacles; mostly US$3.00 readymade (52.8%) and custom-made single vision (29.6%) units. Custom-made spectacles accounted for 36.7% of dispensing, but 73.1% of the US$12,264 urban profit. The combined rural and urban profit covered all rural costs, leaving US$2,200 to meet administration and other urban expenses. It is instructive and encouraging that a national spectacle dispensing program in one of the ten poorest countries of the world can use tiered-pricing based on willingness-to-pay information to cover spectacle stock replacement costs and produce profit, while using cross-subsidization to provide spectacles to the poor.

  1. [Infection control and hand hygiene in nursing homes in Oslo].

    PubMed

    Sie, Ingrid; Thorstad, Margrete; Andersen, Bjørg Marit

    2008-06-26

    Nosocomial infections and transmission can be substantially reduced by good infection control. The laws and regulations for infection control in heath care institutions emphasize establishment of infection control programs and improved hand hygiene. Our study reviews some factors that are important for practicing adequate hand hygiene (knowledge about infection control and hand-washing facilities). Health care workers (HCW) in nursing homes in Oslo participated in this study in 2006-2007. A questionnaire was made and SPSS was used to analyse the data . 70.7% of 324 HCW (in 42 nursing homes) answered the questionnaires. Nearly all of the respondents (95.6%) knew about the written procedures for hygiene and infection control; 88.5% knew that an infection control program was in place and about 50% had received information through internal education. Three of four had read the National guidelines for hand hygiene, 77.5% thought that hand disinfection was more effective than hand washing, and 97% reported hand hygiene after contact with a patient having an infection. Dispensers for hand disinfection were situated at central work places. At the same time, 17.9% informed that they worked in more than one place at the same time. This study confirms that most nursing homes in Oslo have an infection control program and training that improves the knowledge and awareness of hand hygiene among HCWs. However, the fact that nursing homes in Oslo have the resources, knowledge and education, is not the same as compliance.

  2. Understanding private retail drug outlet dispenser knowledge and practices in tuberculosis care in Tanzania.

    PubMed

    Rutta, E; Tarimo, A; Delmotte, E; James, I; Mwakisu, S; Kasembe, D; Konduri, N; Silumbe, R; Kakanda, K; Valimba, R

    2014-09-01

    Private sector accredited drug dispensing outlets in Morogoro and pharmacies in Dar es Salaam, Tanzania. To assess 1) the level of knowledge about tuberculosis (TB) among dispensers in Tanzania's retail pharmaceutical sector; 2) practices related to identification of patients with suspected TB; 3) the availability of educational materials and training; and 4) the availability of first- and second-line anti-tuberculosis treatment in retail drug outlets. A cross-sectional descriptive study involving the administration of a structured questionnaire among drug dispensers in 122 pharmacies and 173 accredited drug dispensing outlets. Private retail drug outlets are convenient; most are open at least 12 h per day, 7 days/week. Although 95% of dispensers identified persistent cough as a symptom of TB, only 1% had received TB-related training in the previous 3 years; 8% of outlets stocked first-line anti-tuberculosis medicines, which are legally prohibited from being sold at retail outlets. The majority of respondents reported seeing clients with TB-like symptoms, and of these 95% reported frequently referring clients to nearby health facilities. Private retail pharmaceutical outlets can potentially contribute to TB case detection and treatment; however, a coordinated effort is needed to train dispensers and implement appropriate referral procedures.

  3. Alcohol Dispenser Training in Amherst Massachusetts

    ERIC Educational Resources Information Center

    Riccelli, Carlene

    1986-01-01

    Reviews efforts of the Alcohol Dispenser Training program in Amherst, Massachusetts over a five-year period. Evaluations indicate that participants agree that training is worthwhile, that they are more aware of the effects of alcohol on their patrons, and that they have better knowledge of appropriate strategies for preventing intoxication of…

  4. Alternative Fuels Data Center: Status Update: E25 Dispensers Certified, E15

    Science.gov Websites

    Alternative Fuels Data Center: Status Update: E25 Dispensers Certified, E15 Warranty Upgraded, and Testing on Ethanol Blends Continues (May 2010) on Facebook Tweet about Alternative Fuels Data Center: Status Update Twitter Bookmark Alternative Fuels Data Center: Status Update: E25 Dispensers Certified, E15 Warranty

  5. Emission characteristics of elm bark beetle aggregation attractants from controlled-release dispensers

    Treesearch

    Roy A. Cuthbert; John W. Peacock; Susan L. Wright

    1983-01-01

    Release rates of the aggregation attractants of the smaller European elm bark beetle, Scolytus multistriatus (Marsham), from laboratory-aged and field-aged Conrel and Hercon dispensers were monitored for 85 days by GLC analysis of cold-trapped volatiles. Both dispensers had relatively low and constant rates of decay for all three attractant...

  6. 22 CFR 401.19 - Reducing or extending time and dispensing with statements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 22 Foreign Relations 2 2012-04-01 2009-04-01 true Reducing or extending time and dispensing with... RULES OF PROCEDURE Applications § 401.19 Reducing or extending time and dispensing with statements. In... Commission may reduce or extend the time for the presentation of any paper or the doing of any act required...

  7. Automated and electronically assisted hand hygiene monitoring systems: a systematic review.

    PubMed

    Ward, Melissa A; Schweizer, Marin L; Polgreen, Philip M; Gupta, Kalpana; Reisinger, Heather S; Perencevich, Eli N

    2014-05-01

    Hand hygiene is one of the most effective ways to prevent transmission of health care-associated infections. Electronic systems and tools are being developed to enhance hand hygiene compliance monitoring. Our systematic review assesses the existing evidence surrounding the adoption and accuracy of automated systems or electronically enhanced direct observations and also reviews the effectiveness of such systems in health care settings. We systematically reviewed PubMed for articles published between January 1, 2000, and March 31, 2013, containing the terms hand AND hygiene or hand AND disinfection or handwashing. Resulting articles were reviewed to determine if an electronic system was used. We identified 42 articles for inclusion. Four types of systems were identified: electronically assisted/enhanced direct observation, video-monitored direct observation systems, electronic dispenser counters, and automated hand hygiene monitoring networks. Fewer than 20% of articles identified included calculations for efficiency or accuracy. Limited data are currently available to recommend adoption of specific automatic or electronically assisted hand hygiene surveillance systems. Future studies should be undertaken that assess the accuracy, effectiveness, and cost-effectiveness of such systems. Given the restricted clinical and infection prevention budgets of most facilities, cost-effectiveness analysis of specific systems will be required before these systems are widely adopted. Published by Mosby, Inc.

  8. Establishment of an efficient virus-induced gene silencing (VIGS) assay in Arabidopsis by Agrobacterium-mediated rubbing infection.

    PubMed

    Manhães, Ana Marcia E de A; de Oliveira, Marcos V V; Shan, Libo

    2015-01-01

    Several VIGS protocols have been established for high-throughput functional genomic screens as it bypasses the time-consuming and laborious process of generation of transgenic plants. The silencing efficiency in this approach is largely hindered by a technically demanding step in which the first pair of newly emerged true leaves at the 2-week-old stage are infiltrated with a needleless syringe. To further optimize VIGS efficiency and achieve rapid inoculation for a large-scale functional genomic study, here we describe a protocol of an efficient VIGS assay in Arabidopsis using Agrobacterium-mediated rubbing infection. The Agrobacterium inoculation is performed by simply rubbing the leaves with Filter Agent Celite(®) 545. The highly efficient and uniform silencing effect was indicated by the development of a visibly albino phenotype due to silencing of the Cloroplastos alterados 1 (CLA1) gene in the newly emerged leaves. In addition, the albino phenotype could be observed in stems and flowers, indicating its potential application for gene functional studies in the late vegetative development and flowering stages.

  9. Evaluation of community pharmacies regarding dispensing practices of antibiotics in two districts of central Nepal.

    PubMed

    Ansari, Mukhtar

    2017-01-01

    To evaluate the status of community pharmacies, their staff, and practices toward dispensing antibiotics. Cross-sectional, prospective. Community pharmacies in two districts of central Nepal, from March 2016 to May 2016. A systematic random sampling approach was adopted to sample 161 community pharmacies. Data on the registration status of pharmacies, qualification or training of dispensing staff, and the practice of dispensing antibiotics were collected using a pre-tested questionnaire. Face to face interviews were carried out by a previously trained interviewer. Data were analyzed for descriptive and inferential statistics using IBM SPSS Statistics 21. Among 161 community pharmacies, 25% were not registered and most of them were located in rural areas. It was typical (66.5%) to dispense antibiotics without prescription and most (91.4%) of the staffs involved in dispensing were non-pharmacists. Furthermore, the study revealed common practices of replacing one brand of antibiotic with other brands (66%), dispensing incomplete courses of antibiotics (73%), and not giving any advice regarding antibiotic use (39%) or completion of a full course of therapy (80%). There were significant (p < 0.001) relationships between the location of pharmacies (rural vs urban) and the qualifications of the pharmacy staff. Dispensing antibiotics without prescription and by non-pharmacists are common in this region. The study also found several issues regarding the irrational use of antibiotics. Thus, there is an urgent need to address these issues and promote the informed use of antibiotics.

  10. Efficacy of a Feed Dispenser for Horses in Decreasing Cribbing Behaviour

    PubMed Central

    Palestrini, Clara; Cannas, Simona; Fè, Eleonora; Bagnato, Gaia Lisa; Vigo, Daniele; Frank, Diane; Minero, Michela

    2016-01-01

    Cribbing is an oral stereotypy, tends to develop in captive animals as a means to cope with stress, and may be indicative of reduced welfare. Highly energetic diets ingested in a short time are one of the most relevant risk factors for the development of cribbing. The aim of this study was to verify whether feeding cribbing horses through a dispenser that delivers small quantities of concentrate when activated by the animal decreases cribbing behaviour, modifies feeding behaviour, or induces frustration. Ten horses (mean age 14 y), balanced for sex, breed, and size (mean height 162 cm), were divided into two groups of 5 horses each: Cribbing and Control. Animals were trained to use the dispenser and videorecorded continuously for 15 consecutive days from 1 h prior to feeding to 2 h after feeding in order to measure their behaviours. The feed dispenser, Quaryka®, induced an increase in time necessary to finish the ration in both groups of horses (P < 0.05). With Quaryka, cribbers showed a significant reduction of time spent cribbing (P < 0.05). After removal of the feed dispenser (Post-Quaryka), cribbing behaviour significantly increased. The use of Quaryka may be particularly beneficial in horses fed high-energy diets and ingesting the food too quickly. PMID:27818832

  11. Smart DNA Fabrication Using Sound Waves: Applying Acoustic Dispensing Technologies to Synthetic Biology.

    PubMed

    Kanigowska, Paulina; Shen, Yue; Zheng, Yijing; Rosser, Susan; Cai, Yizhi

    2016-02-01

    Acoustic droplet ejection (ADE) technology uses focused acoustic energy to transfer nanoliter-scale liquid droplets with high precision and accuracy. This noncontact, tipless, low-volume dispensing technology minimizes the possibility of cross-contamination and potentially reduces the costs of reagents and consumables. To date, acoustic dispensers have mainly been used in screening libraries of compounds. In this paper, we describe the first application of this powerful technology to the rapidly developing field of synthetic biology, for DNA synthesis and assembly at the nanoliter scale using a Labcyte Echo 550 acoustic dispenser. We were able to successfully downscale PCRs and the popular one-pot DNA assembly methods, Golden Gate and Gibson assemblies, from the microliter to the nanoliter scale with high assembly efficiency, which effectively cut the reagent cost by 20- to 100-fold. We envision that acoustic dispensing will become an instrumental technology in synthetic biology, in particular in the era of DNA foundries. © 2015 Society for Laboratory Automation and Screening.

  12. Prescription, dispensation and marketing patterns of methylphenidate

    PubMed Central

    Perini, Edson; Junqueira, Daniela Rezende Garcia; Lana, Lorena Gomes Cunha; Luz, Tatiana Chama Borges

    2014-01-01

    OBJECTIVE To analyze the patterns and legal requirements of methylphenidate consumption. METHODS We conducted a cross-sectional study of the data from prescription notification forms and balance lists of drugs sales – psychoactive and others – subject to special control in the fifth largest city of Brazil, in 2006. We determined the defined and prescribed daily doses, the average prescription and dispensation periods, and the regional sales distribution in the municipality. In addition, we estimated the costs of drug acquisition and analyzed the individual drug consumption profile using the Lorenz curve. RESULTS The balance lists data covered all notified sales of the drug while data from prescription notification forms covered 50.6% of the pharmacies that sold it, including those with the highest sales volumes. Total methylphenidate consumption was 0.37 DDD/1,000 inhabitants/day. Sales were concentrated in more developed areas, and regular-release tablets were the most commonly prescribed pharmaceutical formulation. In some regions of the city, approximately 20.0% of the prescriptions and dispensation exceeded 30 mg/day and 30 days of treatment. CONCLUSIONS Methylphenidate was widely consumed in the municipality and mainly in the most developed areas. Of note, the consumption of formulations with the higher abuse risk was the most predominant. Both its prescription and dispensation contrasted with current pharmacotherapeutic recommendations and legal requirements. Therefore, the commercialization of methylphenidate should be monitored more closely, and its use in the treatment of behavioral changes of psychological disorders needs to be discussed in detail, in line with the concepts of the quality use of medicines. PMID:26039389

  13. In-vivo efficacy of hand sanitisers against feline calicivirus: a surrogate for norovirus.

    PubMed

    Lages, S L S; Ramakrishnan, M A; Goyal, S M

    2008-02-01

    Hand disinfection is considered important in preventing the transmission of viruses, including norovirus. We investigated the virucidal efficacy of nine hand sanitisers (four alcohol-based sanitisers, three non-alcoholic sanitisers and two triclosan-containing antimicrobial liquid soaps) against feline calicivirus, a surrogate for norovirus, on artificially contaminated fingertips for 30 s and 2 min contact periods. Among alcohol-based sanitisers, a product containing 99.5% ethanol was more effective than those containing 62% ethanol, 70% isopropanol or 91% isopropanol. A log(10) virus reduction factor of 1.00-1.30 was achieved with 99.5% ethanol but those containing a lower alcohol concentration only achieved a log(10) reduction factor of hands without any soap (a log(10) reduction factor of 0.33-0.42). These results indicate that triclosan-containing antimicrobial soaps or alcohol-based hand rubs may be inadequate for preventing norovirus transmission. Further research on alternative hand sanitisers should continue for effective control of norovirus infections.

  14. Hand hygiene regimens for the reduction of risk in food service environments.

    PubMed

    Edmonds, Sarah L; McCormack, Robert R; Zhou, Sifang Steve; Macinga, David R; Fricker, Christopher M

    2012-07-01

    Pathogenic strains of Escherichia coli and human norovirus are the main etiologic agents of foodborne illness resulting from inadequate hand hygiene practices by food service workers. This study was conducted to evaluate the antibacterial and antiviral efficacy of various hand hygiene product regimens under different soil conditions representative of those in food service settings and assess the impact of product formulation on this efficacy. On hands contaminated with chicken broth containing E. coli, representing a moderate soil load, a regimen combining an antimicrobial hand washing product with a 70% ethanol advanced formula (EtOH AF) gel achieved a 5.22-log reduction, whereas a nonantimicrobial hand washing product alone achieved a 3.10log reduction. When hands were heavily soiled from handling ground beef containing E. coli, a wash-sanitize regimen with a 0.5% chloroxylenol antimicrobial hand washing product and the 70% EtOH AF gel achieved a 4.60-log reduction, whereas a wash-sanitize regimen with a 62% EtOH foam achieved a 4.11-log reduction. Sanitizing with the 70% EtOH AF gel alone was more effective than hand washing with a nonantimicrobial product for reducing murine norovirus (MNV), a surrogate for human norovirus, with 2.60- and 1.79-log reductions, respectively. When combined with hand washing, the 70% EtOH AF gel produced a 3.19-log reduction against MNV. A regimen using the SaniTwice protocol with the 70% EtOH AF gel produced a 4.04-log reduction against MNV. These data suggest that although the process of hand washing helped to remove pathogens from the hands, use of a wash-sanitize regimen was even more effective for reducing organisms. Use of a high-efficacy sanitizer as part of a wash-sanitize regimen further increased the efficacy of the regimen. The use of a well-formulated alcohol-based hand rub as part of a wash-sanitize regimen should be considered as a means to reduce risk of infection transmission in food service facilities.

  15. Distance traveled and frequency of interstate opioid dispensing in opioid shoppers and nonshoppers.

    PubMed

    Cepeda, M Soledad; Fife, Daniel; Yuan, Yingli; Mastrogiovanni, Greg

    2013-10-01

    Little is known about how far opioid shoppers travel or how often they cross state lines to fill their opioid prescriptions. This retrospective cohort study evaluated these measures for opioid shoppers and nonshoppers using a large U.S. prescription database. Patients with ≥3 opioid dispensings were followed for 18 months. A subject was considered a shopper when he or she filled overlapping opioid prescriptions written by >1 prescriber at ≥3 pharmacies. A heavy shopper had ≥5 shopping episodes. Outcomes assessed were distance traveled among pharmacies and number of states visited to fill opioid prescriptions. A total of 10,910,451 subjects were included; .7% developed any shopping behavior and their prescriptions accounted for 8.6% of all opioid dispensings. Shoppers and heavy shoppers were younger than the nonshoppers. Shoppers traveled a median of 83.8 miles, heavy shoppers 199.5 miles, and nonshoppers 0 miles. Almost 20% of shoppers or heavy shoppers, but only 4% of nonshoppers, visited >1 state. Shoppers traveled greater distances and more often crossed state borders to fill opioid prescriptions than nonshoppers, and their dispensings accounted for a disproportionate number of opioid dispensings. Sharing of data among prescription-monitoring programs will likely strengthen those programs and may decrease shopping behavior. This study shows that opioid shoppers travel greater distances and more often cross state borders to fill opioid prescriptions than nonshoppers, and their dispensings accounted for a disproportionate number of opioid dispensings. The findings support the need for data sharing among prescription-monitoring programs to deter opioid shopping behavior. Copyright © 2013 American Pain Society. Published by Elsevier Inc. All rights reserved.

  16. Private pharmacy staff in Hanoi dispensing steroids - theory and practice

    PubMed Central

    Larsson, Mattias; Binh, Nguyen Thanh; Tomson, Göran; Chuc, Nguyen TK; Falkenberg, Torkel

    Objective To investigate self reported practice and actual practice of private pharmacy staff in relation to drug regulations and provision of prednisolone (a prescription-only corticosteroid) on request to treat lower back pain. Method Sixty private pharmacies in Hanoi were randomly selected. Self reported practice was assessed through interviews with pharmacy staff using a questionnaire; actual practice was assessed with the Simulated Client Method with 5 encounters in each pharmacy (a total of 295 encounters). Results Sixty percent of the pharmacy staff interviewed said that they would not dispense corticosteroids without prescription and 60% could mention some adverse effects. In practice all but one pharmacy dispensed corticosteroids without prescription in 76 % of all the encounters. Questions and advice given to the clients were associated with significantly lower dispensing of corticosteroids. Conclusion The low compliance with prescription regulations and the discrepancy between stated practice and actual practice raises concerns. This study indicates that commercial pressures exceed the deterrent effect of current drug regulations and their implementation and hence enforcement of regulations needs to be improved. PMID:25247001

  17. The impact of dispensing fees on compliance with opioid substitution therapy: a mixed methods study

    PubMed Central

    2014-01-01

    Background Opioid substitution therapy (OST) programs involve the dispensing of OST medicines to patients to address their dependence on heroin and/or other opioid substances. OST medicines are subsidised by the Australian government but patients need to pay the dispensing fees. This study explored opinions from OST patients and stakeholders about the potential impact of dispensing fees on compliance and OST program retention. Current and past experiences and the potential impact of OST dispensing fees were evaluated. Methods Mixed methodology was used to obtain data from OST patients and stakeholders. This involved 1) interviews with OST stakeholders, 2) a focus group of OST patients and 3) surveys of OST patients in Perth, Australia, between June and August 2013. Results The majority of the eight stakeholders declared cost as the factor mostly impacting on OST compliance. Almost all of the stakeholders commented that there was a positive correlation between time on the OST program and success in terms of relapse. Most stakeholders advocated for OST fees to contribute towards the Pharmaceutical Benefits Scheme Safety Net, and for fee subsidy. Focus group themes supported stakeholder interview findings. A total of 138 surveys were completed. Survey analysis illustrated a strong correlation between patient debt and impacted lifestyle: 82.4% (p < 0.001, Chi-square test) of the 138 survey participants stated that dispensing fees impacted significantly on patients’ finances and lifestyle, specifically those patients with major debt. The cost of dispensing fees was identified by 46.3% (64/138) of survey participants as the biggest impacting factor on patient success. Logistic regression models showed that the cost of dispensing fees was also found to significantly influence both the occurrence of debt (57.7%, p < 0.0001) and lifestyle difficulties (80.0%, p = 0.0004). Conclusion Findings provided insight into OST patients’ financial difficulties with

  18. The impact of dispensing fees on compliance with opioid substitution therapy: a mixed methods study.

    PubMed

    Shepherd, Alexandra; Perrella, Bianca; Hattingh, Hendrika Laetitia

    2014-08-10

    Opioid substitution therapy (OST) programs involve the dispensing of OST medicines to patients to address their dependence on heroin and/or other opioid substances. OST medicines are subsidised by the Australian government but patients need to pay the dispensing fees. This study explored opinions from OST patients and stakeholders about the potential impact of dispensing fees on compliance and OST program retention. Current and past experiences and the potential impact of OST dispensing fees were evaluated. Mixed methodology was used to obtain data from OST patients and stakeholders. This involved 1) interviews with OST stakeholders, 2) a focus group of OST patients and 3) surveys of OST patients in Perth, Australia, between June and August 2013. The majority of the eight stakeholders declared cost as the factor mostly impacting on OST compliance. Almost all of the stakeholders commented that there was a positive correlation between time on the OST program and success in terms of relapse. Most stakeholders advocated for OST fees to contribute towards the Pharmaceutical Benefits Scheme Safety Net, and for fee subsidy. Focus group themes supported stakeholder interview findings. A total of 138 surveys were completed. Survey analysis illustrated a strong correlation between patient debt and impacted lifestyle: 82.4% (p < 0.001, Chi-square test) of the 138 survey participants stated that dispensing fees impacted significantly on patients' finances and lifestyle, specifically those patients with major debt. The cost of dispensing fees was identified by 46.3% (64/138) of survey participants as the biggest impacting factor on patient success. Logistic regression models showed that the cost of dispensing fees was also found to significantly influence both the occurrence of debt (57.7%, p < 0.0001) and lifestyle difficulties (80.0%, p = 0.0004). Findings provided insight into OST patients' financial difficulties with data suggesting that dispensing fees are

  19. International Space Station USOS Potable Water Dispenser On-Orbit Functionality Versus Design

    NASA Technical Reports Server (NTRS)

    Toon, Katherine P.; Lovell, Randal W.

    2010-01-01

    The International Space Station (ISS) currently provides potable water dispensing for rehydrating crewmember food and drinking packages. There is one system located in the United States On-orbit Segment (USOS) and one system in the Russian Segment. Shuttle mission STS-126 delivered the USOS Potable Water Dispenser (PWD) to ISS on ULF2; subsequent activation occurred on November 2008. The PWD is capable of supporting an ISS crew of six, but nominally supplies only half this crew size. The PWD design provides incremental quantities of hot and ambient temperature potable water to US food and beverage packages. PWD receives iodinated water from the US Water Recovery System (WRS) Fuel Cell Water Bus, which feeds from the Water Processing Assembly (WPA). The PWD removes the biocidal iodine to make the water potable prior to dispensing. A heater assembly contained within the unit supplies up to 2.0 L of hot water (65 to 93 ?C) every 30 min. During a single meal, this quantity of water supports three to four crewmembers? food rehydration and beverages. The unit design has a functional life expectancy of 10 years, with replacement of limited life items, such as filters. To date, the PWD on-orbit performance is acceptable. Since activation of the PWD, there were several differences between on-orbit functionality and expected performance of hardware design. The comparison of on-orbit functionality to performance of hardware design is discussed for the following key areas: 1) microbial contamination, 2) no-dispense and water leakage scenarios, and 3) under-dispense scenarios.

  20. [Design and piloting of a structured service medication dispensing process].

    PubMed

    Abaurre, Raquel; García-Delgado, Pilar; Maurandi, M Dolores; Arrebola, Cristóbal; Gastelurrutia, Miguel Ángel; Martínez-Martínez, Fernando

    2015-01-01

    The aim of this article is to design and pilot a protocol for the dispensing of medications service. Using the requirements proposed in the Ministry of Health Pharmaceutical Care Consensus, a literature search was made applying qualitative consensus techniques. An observational, cross-sectional study was conducted from March to June 2009. A total of 53 community pharmacies from 24 Spanish counties. Patients who requested one or more particular medications with or without medical prescription for their own use or for someone in their care. The personalised medication information (IPM), the problems associated with the medications (PRM), and the negative results associated with the medication (RNM), detected by the pharmacist each time medication was dispensed, as well as the perception of the pharmacist on the operability of the protocol were recorded. A total of 870 medications were dispensed, with 423 (48.6%) cases of lack of personalised medication information (IPM) being detected. PRM were detected in 10.11% of the dispensed medications, as well as 68 (7.81%) suspected RNM: safety (n = 35; 51.5%), effectiveness (n = 29; 42.6%) and necessity (n = 4; 5.8%). Almost two-thirds (65.21%) of the pharmacists said that the protocol is in operation. The designed protocol helped to detect deficiencies in the information to the patients about their medications, as well as the PRM and RNM, and is shown to be tool that is easy to use and apply. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  1. Cell division is dispensable but not irrelevant in Streptomyces.

    PubMed

    McCormick, Joseph R

    2009-12-01

    In part, members of the genus Streptomyces have been studied because they produce many important secondary metabolites with antibiotic activity and for the interest in their relatively elaborate life cycle. These sporulating filamentous bacteria are remarkably synchronous for division and genome segregation in specialized aerial hyphae. Streptomycetes share some, but not all, of the division genes identified in the historic model rod-shaped organisms. Curiously, normally essential cell division genes are dispensable for growth and viability of Streptomyces coelicolor. Mainly, cell division plays a more important role in the developmental phase of life than during vegetative growth. Dispensability provides an advantageous genetic system to probe the mechanisms of division proteins, especially those with functions that are poorly understood.

  2. Technical considerations in the preparation and dispensing of chemotherapy.

    PubMed

    Peters, B G

    1995-01-01

    The safe handling of cytotoxic agents is intimately related to the technical aspects of drug preparation, dispensing, and administration. The appropriate equipment, supplies, protective clothing, and waste disposal systems must be available to the health care worker who is called upon to prepare cytotoxic agents. In addition, the health care worker must be adequately trained in and familiar with the safe use of these products and equipment and the preparation techniques or manipulations necessary during cytotoxic drug compounding. The article describes in detail and reviews the technical considerations, such as aseptic technique, proper use of the biological safety cabinet, gowning and gloving, labeling, and waste disposal, that are essential to the safe preparation and dispensing of chemotherapy.

  3. Deterministic bead-in-droplet ejection utilizing an integrated plug-in bead dispenser for single bead-based applications

    NASA Astrophysics Data System (ADS)

    Kim, Hojin; Choi, In Ho; Lee, Sanghyun; Won, Dong-Joon; Oh, Yong Suk; Kwon, Donghoon; Sung, Hyung Jin; Jeon, Sangmin; Kim, Joonwon

    2017-04-01

    This paper presents a deterministic bead-in-droplet ejection (BIDE) technique that regulates the precise distribution of microbeads in an ejected droplet. The deterministic BIDE was realized through the effective integration of a microfluidic single-particle handling technique with a liquid dispensing system. The integrated bead dispenser facilitates the transfer of the desired number of beads into a dispensing volume and the on-demand ejection of bead-encapsulated droplets. Single bead-encapsulated droplets were ejected every 3 s without any failure. Multiple-bead dispensing with deterministic control of the number of beads was demonstrated to emphasize the originality and quality of the proposed dispensing technique. The dispenser was mounted using a plug-socket type connection, and the dispensing process was completely automated using a programmed sequence without any microscopic observation. To demonstrate a potential application of the technique, bead-based streptavidin-biotin binding assay in an evaporating droplet was conducted using ultralow numbers of beads. The results evidenced the number of beads in the droplet crucially influences the reliability of the assay. Therefore, the proposed deterministic bead-in-droplet technology can be utilized to deliver desired beads onto a reaction site, particularly to reliably and efficiently enrich and detect target biomolecules.

  4. Deterministic bead-in-droplet ejection utilizing an integrated plug-in bead dispenser for single bead-based applications.

    PubMed

    Kim, Hojin; Choi, In Ho; Lee, Sanghyun; Won, Dong-Joon; Oh, Yong Suk; Kwon, Donghoon; Sung, Hyung Jin; Jeon, Sangmin; Kim, Joonwon

    2017-04-10

    This paper presents a deterministic bead-in-droplet ejection (BIDE) technique that regulates the precise distribution of microbeads in an ejected droplet. The deterministic BIDE was realized through the effective integration of a microfluidic single-particle handling technique with a liquid dispensing system. The integrated bead dispenser facilitates the transfer of the desired number of beads into a dispensing volume and the on-demand ejection of bead-encapsulated droplets. Single bead-encapsulated droplets were ejected every 3 s without any failure. Multiple-bead dispensing with deterministic control of the number of beads was demonstrated to emphasize the originality and quality of the proposed dispensing technique. The dispenser was mounted using a plug-socket type connection, and the dispensing process was completely automated using a programmed sequence without any microscopic observation. To demonstrate a potential application of the technique, bead-based streptavidin-biotin binding assay in an evaporating droplet was conducted using ultralow numbers of beads. The results evidenced the number of beads in the droplet crucially influences the reliability of the assay. Therefore, the proposed deterministic bead-in-droplet technology can be utilized to deliver desired beads onto a reaction site, particularly to reliably and efficiently enrich and detect target biomolecules.

  5. Deterministic bead-in-droplet ejection utilizing an integrated plug-in bead dispenser for single bead–based applications

    PubMed Central

    Kim, Hojin; Choi, In Ho; Lee, Sanghyun; Won, Dong-Joon; Oh, Yong Suk; Kwon, Donghoon; Sung, Hyung Jin; Jeon, Sangmin; Kim, Joonwon

    2017-01-01

    This paper presents a deterministic bead-in-droplet ejection (BIDE) technique that regulates the precise distribution of microbeads in an ejected droplet. The deterministic BIDE was realized through the effective integration of a microfluidic single-particle handling technique with a liquid dispensing system. The integrated bead dispenser facilitates the transfer of the desired number of beads into a dispensing volume and the on-demand ejection of bead-encapsulated droplets. Single bead–encapsulated droplets were ejected every 3 s without any failure. Multiple-bead dispensing with deterministic control of the number of beads was demonstrated to emphasize the originality and quality of the proposed dispensing technique. The dispenser was mounted using a plug-socket type connection, and the dispensing process was completely automated using a programmed sequence without any microscopic observation. To demonstrate a potential application of the technique, bead-based streptavidin–biotin binding assay in an evaporating droplet was conducted using ultralow numbers of beads. The results evidenced the number of beads in the droplet crucially influences the reliability of the assay. Therefore, the proposed deterministic bead-in-droplet technology can be utilized to deliver desired beads onto a reaction site, particularly to reliably and efficiently enrich and detect target biomolecules. PMID:28393911

  6. [Influence of promotional material on hand hygiene in the safety culture of a tertiary hospital].

    PubMed

    Molina-Cabrillana, J; Dorta-Hung, M E; Otero Sanz, L; Henández Vera, J R; Martín-Rodríguez, M M; García de Carlos, P

    2016-06-01

    In order to increase safety culture about hand hygiene by means of messages and reminders about its importance in preventing nosocomial infections, we developed a new set of materials in the Complejo Hospitalario Universitario Insular Materno-Infantil of Las Palmas, Gran Canaria, constitued by two centres with 450 beds each and acredited for medical internal residents training. We hired a well-known caricaturist, who adapted the messages to the local way of speaking, by using characters that used to appear in his artwork in the local newspaper. Also, we continued to work with other graphic design professionals. We monitored adherence and consumption of products for hand rubbing. We noted an increase in both indicators in the following months after the implementation of this strategy. Moreover, we revised the infrastructures for hand hygiene, and were able to demonstrate improvements in most of the patient care areas. The material was well accepted by professionals, patients and visitors. No other interventions were made, so we think improvements can be attributable to this strategy in our setting. Copyright © 2016 SECA. Published by Elsevier Espana. All rights reserved.

  7. A test procedure for evaluating surgical hand disinfection.

    PubMed

    Babb, J R; Davies, J G; Ayliffe, G A

    1991-06-01

    A technique for assessing the immediate and prolonged efficacy of surgical scrubs and alcoholic hand rubs is described. A mean baseline count is obtained from all volunteers and logarithmic reductions in resident skin flora immediately after one or more applications, and after wearing gloves for 3 h, are measured. Loose-fitting surgical gloves are used for sampling resident flora. Preparations were applied using a standard technique for 2 min, apart from one test with 70% isopropanol (IPA) in which the application time was 30 s. Two studies are described, one of which compared four chlorhexidine scrubs, and the second 70% IPA, 7.5% povidone-iodine scrub, 2% triclosan cleanser and unmedicated bar soap. In spite of their constituent similarity, the four chlorhexidine scrubs varied considerably in efficacy and user acceptability. A 2 min application of 70% IPA was the most effective treatment, and gave log10 reductions of 1.65 for immediate and 1.58 for prolonged effect. This was marginally more effective than a 30 s application, but the difference was not significant. 'Hibiscrub' was the most effective aqueous formulation and gave reductions of 1.01 for immediate effect and 1.16 for prolonged effect. The test described could be used by reference centres and manufacturers to assess the efficacy of new and existing surgical hand disinfection formulations.

  8. A Sequential Insect Dispenser for Behavioral Experiments

    ERIC Educational Resources Information Center

    Gans, Carl; Mix, Harold

    1974-01-01

    Describes the construction and operation of an automatic insect dispenser suitable for feeding small vertebrates that are being maintained for behavioral experiments. The food morsels are squirted from their chambers an an air jet, and may be directed at a particluar portion of the cage or distributed to different areas. (JR)

  9. 14 CFR 137.37 - Manner of dispensing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Manner of dispensing. 137.37 Section 137.37 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS... aircraft, any material or substance in a manner that creates a hazard to persons or property on the surface...

  10. 14 CFR 137.37 - Manner of dispensing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Manner of dispensing. 137.37 Section 137.37 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS... aircraft, any material or substance in a manner that creates a hazard to persons or property on the surface...

  11. 14 CFR 137.37 - Manner of dispensing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Manner of dispensing. 137.37 Section 137.37 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS... aircraft, any material or substance in a manner that creates a hazard to persons or property on the surface...

  12. 14 CFR 137.37 - Manner of dispensing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Manner of dispensing. 137.37 Section 137.37 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS... aircraft, any material or substance in a manner that creates a hazard to persons or property on the surface...

  13. Documentation of study medication dispensing in a prospective large randomized clinical trial: experiences from the ARISTOTLE Trial.

    PubMed

    Alexander, John H; Levy, Elliott; Lawrence, Jack; Hanna, Michael; Waclawski, Anthony P; Wang, Junyuan; Califf, Robert M; Wallentin, Lars; Granger, Christopher B

    2013-09-01

    In ARISTOTLE, apixaban resulted in a 21% reduction in stroke, a 31% reduction in major bleeding, and an 11% reduction in death. However, approval of apixaban was delayed to investigate a statement in the clinical study report that "7.3% of subjects in the apixaban group and 1.2% of subjects in the warfarin group received, at some point during the study, a container of the wrong type." Rates of study medication dispensing error were characterized through reviews of study medication container tear-off labels in 6,520 participants from randomly selected study sites. The potential effect of dispensing errors on study outcomes was statistically simulated in sensitivity analyses in the overall population. The rate of medication dispensing error resulting in treatment error was 0.04%. Rates of participants receiving at least 1 incorrect container were 1.04% (34/3,273) in the apixaban group and 0.77% (25/3,247) in the warfarin group. Most of the originally reported errors were data entry errors in which the correct medication container was dispensed but the wrong container number was entered into the case report form. Sensitivity simulations in the overall trial population showed no meaningful effect of medication dispensing error on the main efficacy and safety outcomes. Rates of medication dispensing error were low and balanced between treatment groups. The initially reported dispensing error rate was the result of data recording and data management errors and not true medication dispensing errors. These analyses confirm the previously reported results of ARISTOTLE. © 2013.

  14. Physician Dispensing of Oxycodone and Other Commonly Used Opioids, 2000-2015, United States.

    PubMed

    Mack, Karin Ann; Jones, Christopher McCall; McClure, Roderick John

    2018-05-01

    An average of 91 people in the United States die every day from an opioid-related overdose (including prescription opioids and heroin). The direct dispensing of opioids from health care practitioner offices has been linked to opioid-related harms. The objective of this study is to describe the changing nature of the volume of this type of prescribing at the state level. This descriptive study examines the distribution of opioids by practitioners using 1999-2015 Automation of Reports and Consolidated Orders System data. Analyses were restricted to opioids distributed to practitioners. Amount distributed (morphine milligram equivalents [MMEs]) and number of practitioners are presented. Patterns of distribution to practitioners and the number of practitioners varied markedly by state and changed dramatically over time. Comparing 1999 with 2015, the MME distributed to dispensing practitioners decreased in 16 states and increased in 35. Most notable was the change in Florida, which saw a peak of 8.94 MMEs per 100,000 persons in 2010 (the highest distribution in all states in all years) and a low of 0.08 in 2013. This study presents the first state estimates of office-based dispensing of opioids. Increases in direct dispensing in recent years may indicate a need to monitor this practice and consider whether changes are needed. Using controlled substances data to identify high prescribers and dispensers of opioids, as well as examining overall state trends, is a foundational activity to informing the response to potentially high-risk clinical practices.

  15. The expected and unexpected benefits of dispensing the exact number of pills.

    PubMed

    Treibich, Carole; Lescher, Sabine; Sagaon-Teyssier, Luis; Ventelou, Bruno

    2017-01-01

    From November 2014 to November 2015, an experiment in French community pharmacies replaced traditional pre-packed boxes by per-unit dispensing of pills in the exact numbers prescribed, for 14 antibiotics. A cluster randomised control trial was carried out in 100 pharmacies. 75 pharmacies counted out the medication by units (experimental group), the other 25 providing the treatment in the existing pharmaceutical company boxes (control group). Data on patients under the two arms were compared to assess the environmental, economic and health effects of this change in drug dispensing. In particular, adherence was measured indirectly by comparing the number of pills left at the end of the prescribed treatment. Out of the 1185 patients included during 3 sessions of 4 consecutive weeks each, 907 patients experimented the personalized delivery and 278 were assigned to the control group, consistent with a 1/3 randomization-rate at the pharmacy level. 80% of eligible patients approved of the per-unit dispensing of their treatment. The initial packaging of the drugs did not match with the prescription in 60% of cases and per-unit dispensing reduced by 10% the number of pills supplied. 13.1% of patients declared that they threw away pills residuals instead of recycling-no differences between groups. Finally, per-unit dispensing appeared to improve adherence to antibiotic treatment (marginal effect 0.21, IC 95, 0.14-0.28). Supplying antibiotics per unit is not only beneficial in terms of a reduced number of pills to reimburse or for the environment (less pills wasted and non-recycled), but also has a positive and unexpected impact on adherence to treatment, and thus on both individual and public health.

  16. International Space Station USOS Potable Water Dispenser On-Orbit Functionality vs Design

    NASA Technical Reports Server (NTRS)

    Toon, Katherine P.; Lovell, Randal W.

    2009-01-01

    The International Space Station (ISS) currently provides potable water dispensing for rehydrating crewmembers food and drinking packages with one system located in the United States On-orbit Segment (USOS) and one system in the Russian Segment. The USOS Potable Water Dispenser (PWD) was delivered to ISS on ULF2, Shuttle Mission STS-126, and was subsequently activated in November 2008. The PWD activation on ISS is capable of supporting an ISS crew of six but nominally supplies only half the crew. The PWD is designed to provide incremental quantities of hot and ambient temperature potable water to US style food packages. PWD receives iodinated water from the US Laboratory Fuel Cell Water Bus, which is fed from the Water Processing Assembly (WPA). The PWD removes the biocidal iodine to make the water potable prior to dispensing. A heater assembly contained within the unit supplies up to 2.0 liters of hot water (65 to 93oC) every thirty minutes. This quantity supports three to four crewmembers to rehydrate their food and beverages from this location during a single meal. The unit is designed to remain functional for up to ten years with replacement of limited life items such as filters. To date, the PWD on-orbit performance has been acceptable. Since activation of the PWD, there have been several differences between on-orbit functionality and expected performance of hardware design. The comparison of on-orbit functionality to performance of hardware design is outlined for the following key areas: microbiology, PWD to food package water leakage, no-dispense scenarios, under-dispense scenarios, and crewmember feedback on actual on-orbit use.

  17. Development of an Isolator System for PET Drug Compounding with Sterilization and Dispensing Units.

    PubMed

    Waki, Atsuo; Hashimoto, Yuuki; Suzuki, Hisashi; Mizukawa, Yousuke; Kinoshita, Toshiaki; Ichihara, Hironobu; Kaneko, Izumi; Iwakuma, Kazuko; Kawamura, Kazuki; Zhang, Ming-Rong; Fujibayashi, Yasuhisa

    2016-01-01

    To maintain sterility of PET drug is the most important for in-house positron emission tomography (PET) drug manufacturing, and sanitary control of the laboratory to perform aseptic procedure is the key point for the sterility of PET drugs. However, rigorous sanitary control affects both the high cost and the low efficiency. To conquer those, we developed an isolator system especially for PET drug compounding including sterilization and dispensing units. This system consists of a HEPA unit for inlet and outlet, positive regulation of the ear inside isolator, a sterilizer with vapored hydrogen peroxide and a dispenser with self-shield for radiation. We set the materials for the dispenser through gloves, and the compounding such as sterilization and dispensing PET drugs to the containers is performed automatically without radiation. High level assurance of PET drug sterility is expected to be accomplished in the PET centers of the hospitals without high level sanitary control.

  18. Effectiveness of liquid soap and hand sanitizer against Norwalk virus on contaminated hands.

    PubMed

    Liu, Pengbo; Yuen, Yvonne; Hsiao, Hui-Mien; Jaykus, Lee-Ann; Moe, Christine

    2010-01-01

    Disinfection is an essential measure for interrupting human norovirus (HuNoV) transmission, but it is difficult to evaluate the efficacy of disinfectants due to the absence of a practicable cell culture system for these viruses. The purpose of this study was to screen sodium hypochlorite and ethanol for efficacy against Norwalk virus (NV) and expand the studies to evaluate the efficacy of antibacterial liquid soap and alcohol-based hand sanitizer for the inactivation of NV on human finger pads. Samples were tested by real-time reverse transcription-quantitative PCR (RT-qPCR) both with and without a prior RNase treatment. In suspension assay, sodium hypochlorite concentrations of >or=160 ppm effectively eliminated RT-qPCR detection signal, while ethanol, regardless of concentration, was relatively ineffective, giving at most a 0.5 log(10) reduction in genomic copies of NV cDNA. Using the American Society for Testing and Materials (ASTM) standard finger pad method and a modification thereof (with rubbing), we observed the greatest reduction in genomic copies of NV cDNA with the antibacterial liquid soap treatment (0.67 to 1.20 log(10) reduction) and water rinse only (0.58 to 1.58 log(10) reduction). The alcohol-based hand sanitizer was relatively ineffective, reducing the genomic copies of NV cDNA by only 0.14 to 0.34 log(10) compared to baseline. Although the concentrations of genomic copies of NV cDNA were consistently lower on finger pad eluates pretreated with RNase compared to those without prior RNase treatment, these differences were not statistically significant. Despite the promise of alcohol-based sanitizers for the control of pathogen transmission, they may be relatively ineffective against the HuNoV, reinforcing the need to develop and evaluate new products against this important group of viruses.

  19. The effect of automated monitoring and real-time prompting on nurses' hand hygiene performance.

    PubMed

    Levchenko, Alexander I; Boscart, Veronique M; Fernie, Geoff R

    2013-10-01

    Adequate hand hygiene compliance by healthcare staff is considered an effective method to reduce hospital-acquired infections. The electronic system developed at Toronto Rehabilitation Institute automatically detects hand hygiene opportunities and records hand hygiene actions. It includes an optional visual hand hygiene status indication, generates real-time hand hygiene prompting signals, and enables automated monitoring of individual and aggregated hand hygiene performance. The system was installed on a complex continuous care unit at the entrance to 17 patient rooms and a utility room. A total of 93 alcohol gel and soap dispensers were instrumented and 14 nurses were provided with the personal wearable electronic monitors. The study included three phases with the system operating in three different modes: (1) an inactive mode during the first phase when hand hygiene opportunities and hand hygiene actions were recorded but prompting and visual indication functions were disabled, (2) only hand hygiene status indicators were enabled during the second phase, and (3) both hand hygiene status and real-time hand hygiene prompting signals were enabled during the third phase. Data collection was performed automatically during all of the three phases. The system indicated significantly higher hand hygiene activity rates and compliance during the third phase, with both hand hygiene indication and real-time prompting functions enabled. To increase the efficacy of the technology, its use was supplemented with individual performance reviews of the automatically collected data.

  20. [Quality evaluation of rhubarb dispensing granules based on multi-component simultaneous quantitative analysis and bioassay].

    PubMed

    Tan, Peng; Zhang, Hai-Zhu; Zhang, Ding-Kun; Wu, Shan-Na; Niu, Ming; Wang, Jia-Bo; Xiao, Xiao-He

    2017-07-01

    This study attempts to evaluate the quality of Chinese formula granules by combined use of multi-component simultaneous quantitative analysis and bioassay. The rhubarb dispensing granules were used as the model drug for demonstrative study. The ultra-high performance liquid chromatography (UPLC) method was adopted for simultaneously quantitative determination of the 10 anthraquinone derivatives (such as aloe emodin-8-O-β-D-glucoside) in rhubarb dispensing granules; purgative biopotency of different batches of rhubarb dispensing granules was determined based on compound diphenoxylate tablets-induced mouse constipation model; blood activating biopotency of different batches of rhubarb dispensing granules was determined based on in vitro rat antiplatelet aggregation model; SPSS 22.0 statistical software was used for correlation analysis between 10 anthraquinone derivatives and purgative biopotency, blood activating biopotency. The results of multi-components simultaneous quantitative analysisshowed that there was a great difference in chemical characterizationand certain differences inpurgative biopotency and blood activating biopotency among 10 batches of rhubarb dispensing granules. The correlation analysis showed that the intensity of purgative biopotency was significantly correlated with the content of conjugated anthraquinone glycosides (P<0.01), and the intensity of blood activating biopotency was significantly correlated with the content of free anthraquinone (P<0.01). In summary, the combined use of multi-component simultaneous quantitative analysis and bioassay can achieve objective quantification and more comprehensive reflection on overall quality difference among different batches of rhubarb dispensing granules. Copyright© by the Chinese Pharmaceutical Association.

  1. Nanomachining by rubbing at ultrasonic frequency under controlled shear force.

    PubMed

    Muraoka, Mikio

    2011-03-01

    This study proposes a new method of proximal-probe machining that uses a rubbing process by introducing concentrated-mass (CM) cantilevers. At the second resonance of the CM cantilever vibration, the tip site of the cantilever becomes a node of the standing deflection wave because of the sufficient inertia of the attached concentrated mass. The tip makes a cyclic motion that is tangential to the sample surface, not vertical to it, as in a tapping motion. This lateral tip motion that is selectively excited by CM cantilevers was effective for the material modification of a sample due to the friction between the tip and the sample. Imaging and nanomachining under controlled shear force were demonstrated by means of the modified cantilever and a normal atomic force microscope. We were able to write a micron-sized letter "Z" having a line width of 30-100 nm on a resin surface.

  2. [Dispensing prescriptions to persons affiliated with the Seguro Popular de Salud de México].

    PubMed

    Garrido-Latorre, Francisco; Hernández-Llamas, Héctor; Gómez-Dantés, Octavio

    2008-01-01

    Measure and compare the percentage of prescriptions fully dispensed to persons with and without Popular Health Insurance (SPS in Spanish) who use ambulatory and general hospital services associated with the Mexico State Health Services (SESA in Spanish), and taking into account insurance status. SESA user satisfaction was also measured with respect to access to medication. Information for the study was taken from four surveys of SESA ambulatory and hospital units that included probabilistic samples with state representativity. Samples of ambulatory units were selected by stratification according to level of care and association to the SPS service network. The findings indicate that the percentage of prescriptions fully dispensed in SESA ambulatory units has improved, reaching approximately 90%, especially among those units offering services to persons affiliated with SPS. Nevertheless, these percentages continue to be lower than those of ambulatory units associated with social security institutions. Percentages of prescriptions fully dispensed have also improved in SESA hospital units, but continue to be relatively low. In nearly all states, as the percentage of prescriptions fully dispensed has increased, user satisfaction with access to medication has also improved. In 2006 more than 50% of the states had high levels of fully dispensed prescriptions among persons with SPS (> or =90%). The more significant problem exists among hospitals, since only 44% of users who received a prescription in SESA hospitals in 2006 had their prescriptions fully dispensed. This finding requires a review of SPS medication policies, which have favored highly prescribed low-cost medications at ambulatory services at the expense of higher cost and more therapeutically effective medications for hospital care, the latter having a greater impact on household budgets.

  3. Mass prophylaxis dispensing concerns: traffic and public access to PODs.

    PubMed

    Baccam, Prasith; Willauer, David; Krometis, Justin; Ma, Yongchang; Sen, Atri; Boechler, Michael

    2011-06-01

    The ability to quickly dispense postexposure prophylaxis (PEP) using multiple points of dispensing (PODs) following a bioterrorism event could potentially save a large proportion of those who were exposed, while failure in PEP dispensing could have dire public health consequences. A Monte Carlo simulation was developed to explore the traffic flow and parking around PODs under different arrival rates and how these factors might affect the utilization rate of POD workers. The results demonstrate that the public can reasonably access the PODs under ideal conditions assuming a stationary (uniform) arrival rate. For the 5 nonstationary arrival rates tested, however, the available parking spaces quickly become filled, causing long traffic queues and resulting in total processing times that range from 1 hour to over 6 hours. Basic planning considerations should include the use of physical barriers, signage, and traffic control officers to help direct vehicular and pedestrian access to the PODs. Furthermore, the parking and traffic surrounding PODs creates long queues of people waiting to access the PODs. Thus, POD staff are fully used approximately 90% of the time, which can lead to worker fatigue and burn out.

  4. Exploring safety systems for dispensing in community pharmacies: focusing on how staff relate to organizational components.

    PubMed

    Harvey, Jasmine; Avery, Anthony J; Ashcroft, Darren; Boyd, Matthew; Phipps, Denham L; Barber, Nicholas

    2015-01-01

    Identifying risk is an important facet of a safety practice in an organization. To identify risk, all components within a system of operation should be considered. In clinical safety practice, a team of people, technologies, procedures and protocols, management structure and environment have been identified as key components in a system of operation. To explore risks in relation to prescription dispensing in community pharmacies by taking into account relationships between key components that relate to the dispensing process. Fifteen community pharmacies in England with varied characteristics were identified, and data were collected using non-participant observations, shadowing and interviews. Approximately 360 hours of observations and 38 interviews were conducted by the team. Observation field notes from each pharmacy were written into case studies. Overall, 52,500 words from 15 case studies and interview transcripts were analyzed using thematic and line-by-line analyses. Validation techniques included multiple data collectors co-authoring each case study for consensus, review of case studies by members of the wider team including academic and practicing community pharmacists, and patient safety experts and two presentations (internally and externally) to review and discuss findings. Risks identified were related to relationships between people and other key components in dispensing. This included how different levels of staff communicated internally and externally, followed procedures, interacted with technical systems, worked with management, and engaged with the environment. In a dispensing journey, the following categories were identified which show how risks are inextricably linked through relationships between human components and other key components: 1) dispensing with divided attention; 2) dispensing under pressure; 3) dispensing in a restricted space or environment; and, 4) managing external influences. To identify and evaluate risks effectively, an

  5. Impact of a standardized hand hygiene program on the incidence of nosocomial infection in very low birth weight infants.

    PubMed

    Capretti, Maria Grazia; Sandri, Fabrizio; Tridapalli, Elisabetta; Galletti, Silvia; Petracci, Elisabetta; Faldella, Giacomo

    2008-08-01

    This study examined the effects of a standardized hand hygiene program on the rate of nosocomial infection (NI) in very low birth weight (VLBW) infants (birth weight < 1500 g) admitted to our neonatal intensive care unit (NICU). We compared the rate of NI in VLBW infants in 2 separate periods. In the first period, staff were encouraged to perform handwashing using a plain fluid detergent (0.5% triclosan). In the second period, a standardized hand hygiene program was implemented using antimicrobial soap (4% chlorhexidine gluconate) and alcohol-based hand rubs. NI after 72 hours of life was detected in 16 of the 85 VLBW infants in the first period and in 5 of the 80 VLBW infants in the second period. The rate of central venous catheter colonization was significantly lower in the second period (5.8%) than in the first period (16.6%). In our NICU, the incidence of NI in VLBW infants was significantly reduced after the introduction of a standardized handwashing protocol. In our experience, a proper hand hygiene program can save approximately 10 NI episodes/year, at a cost of $10,000 per episode. Therefore, improving hand hygiene practice is a cost-effective program in the NICU.

  6. Perception of Community Pharmacists towards Dispensing Errors in Community Pharmacy Setting in Gondar Town, Northwest Ethiopia

    PubMed Central

    2017-01-01

    Background Dispensing errors are inevitable occurrences in community pharmacies across the world. Objective This study aimed to identify the community pharmacists' perception towards dispensing errors in the community pharmacies in Gondar town, Northwest Ethiopia. Methods A cross-sectional study was conducted among 47 community pharmacists selected through convenience sampling. Data were analyzed using SPSS version 20. Descriptive statistics, Mann–Whitney U test, and Pearson's Chi-square test of independence were conducted with P ≤ 0.05 considered statistically significant. Result The majority of respondents were in the 23–28-year age group (N = 26, 55.3%) and with at least B.Pharm degree (N = 25, 53.2%). Poor prescription handwriting and similar/confusing names were perceived to be the main contributing factors while all the strategies and types of dispensing errors were highly acknowledged by the respondents. Group differences (P < 0.05) in opinions were largely due to educational level and age. Conclusion Dispensing errors were associated with prescribing quality and design of dispensary as well as dispensing procedures. Opinion differences relate to age and educational status of the respondents. PMID:28612023

  7. Perception of Community Pharmacists towards Dispensing Errors in Community Pharmacy Setting in Gondar Town, Northwest Ethiopia.

    PubMed

    Asmelashe Gelayee, Dessalegn; Binega Mekonnen, Gashaw

    2017-01-01

    Dispensing errors are inevitable occurrences in community pharmacies across the world. This study aimed to identify the community pharmacists' perception towards dispensing errors in the community pharmacies in Gondar town, Northwest Ethiopia. A cross-sectional study was conducted among 47 community pharmacists selected through convenience sampling. Data were analyzed using SPSS version 20. Descriptive statistics, Mann-Whitney U test, and Pearson's Chi-square test of independence were conducted with P ≤ 0.05 considered statistically significant. The majority of respondents were in the 23-28-year age group ( N = 26, 55.3%) and with at least B.Pharm degree ( N = 25, 53.2%). Poor prescription handwriting and similar/confusing names were perceived to be the main contributing factors while all the strategies and types of dispensing errors were highly acknowledged by the respondents. Group differences ( P < 0.05) in opinions were largely due to educational level and age. Dispensing errors were associated with prescribing quality and design of dispensary as well as dispensing procedures. Opinion differences relate to age and educational status of the respondents.

  8. The expected and unexpected benefits of dispensing the exact number of pills

    PubMed Central

    Lescher, Sabine; Sagaon-Teyssier, Luis; Ventelou, Bruno

    2017-01-01

    Background From November 2014 to November 2015, an experiment in French community pharmacies replaced traditional pre-packed boxes by per-unit dispensing of pills in the exact numbers prescribed, for 14 antibiotics. Methods A cluster randomised control trial was carried out in 100 pharmacies. 75 pharmacies counted out the medication by units (experimental group), the other 25 providing the treatment in the existing pharmaceutical company boxes (control group). Data on patients under the two arms were compared to assess the environmental, economic and health effects of this change in drug dispensing. In particular, adherence was measured indirectly by comparing the number of pills left at the end of the prescribed treatment. Results Out of the 1185 patients included during 3 sessions of 4 consecutive weeks each, 907 patients experimented the personalized delivery and 278 were assigned to the control group, consistent with a 1/3 randomization-rate at the pharmacy level. 80% of eligible patients approved of the per-unit dispensing of their treatment. The initial packaging of the drugs did not match with the prescription in 60% of cases and per-unit dispensing reduced by 10% the number of pills supplied. 13.1% of patients declared that they threw away pills residuals instead of recycling—no differences between groups. Finally, per-unit dispensing appeared to improve adherence to antibiotic treatment (marginal effect 0.21, IC 95, 0.14–0.28). Conclusions Supplying antibiotics per unit is not only beneficial in terms of a reduced number of pills to reimburse or for the environment (less pills wasted and non-recycled), but also has a positive and unexpected impact on adherence to treatment, and thus on both individual and public health. PMID:28926636

  9. A comparison of hand washing techniques to remove Escherichia coli and caliciviruses under natural or artificial fingernails.

    PubMed

    Lin, Chia-Min; Wu, Fone-Mao; Kim, Hoi-Kyung; Doyle, Michael P; Michael, Barry S; Williams, L Keoki

    2003-12-01

    Compared with other parts of the hand, the area beneath fingernails harbors the most microorganisms and is most difficult to clean. Artificial fingernails, which are usually long and polished, reportedly harbor higher microbial populations than natural nails. Hence, the efficacy of different hand washing methods for removing microbes from natural and artificial fingernails was evaluated. Strains of nonpathogenic Escherichia coli JM109 and feline calicivirus (FCV) strain F9 were used as bacterial and viral indicators, respectively. Volunteers with artificial or natural nails were artificially contaminated with ground beef containing E. coli JM109 or artificial feces containing FCV. Volunteers washed their hands with tap water, regular liquid soap, antibacterial liquid soap, alcohol-based hand sanitizer gel, regular liquid soap followed by alcohol gel, or regular liquid soap plus a nailbrush. The greatest reduction of inoculated microbial populations was obtained by washing with liquid soap plus a nailbrush, and the least reduction was obtained by rubbing hands with alcohol gel. Lower but not significantly different (P > 0.05) reductions of E. coli and FCV counts were obtained from beneath artificial than from natural fingernails. However, significantly (P < or = 0.05) higher E. coli and FCV counts were recovered from hands with artificial nails than from natural nails before and after hand washing. In addition, microbial cell numbers were correlated with fingernail length, with greater numbers beneath fingernails with longer nails. These results indicate that best practices for fingernail sanitation of food handlers are to maintain short fingernails and scrub fingernails with soap and a nailbrush when washing hands.

  10. Use of direct washing of chemical dispense nozzle for defect control

    NASA Astrophysics Data System (ADS)

    Linnane, Michael; Mack, George; Longstaff, Christopher; Winter, Thomas

    2006-03-01

    Demands for continued defect reduction in 300mm IC manufacturing are driving process engineers to examine all aspects of the chemical apply process for improvement. Historically, the defect contribution from photoresist apply nozzles has been minimized through a carefully controlled process of "dummy dispenses" to keep the photoresist in the tip "fresh" and remove any solidified material, a preventive maintenance regime involving periodic cleaning or replacing of the nozzles, and reliance on a pool of solvent within the nozzle storage block to keep the photoresist from solidifying at the nozzle tip. The industry standard has worked well for the most part but has limitations in terms of cost effectiveness and absolute defect elimination. In this study, we investigate the direct washing of the chemical apply nozzle to reduce defects seen on the coated wafer. Data is presented on how the direct washing of the chemical dispense nozzle can be used to reduce coating related defects, reduce material costs from the reduction of "dummy dispense", and can reduce equipment downtime related to nozzle cleaning or replacement.

  11. Implementing a bar-code assisted medication administration system: effects on the dispensing process and user perceptions.

    PubMed

    Samaranayake, N R; Cheung, S T D; Cheng, K; Lai, K; Chui, W C M; Cheung, B M Y

    2014-06-01

    We assessed the effects of a bar-code assisted medication administration system used without the support of computerised prescribing (stand-alone BCMA), on the dispensing process and its users. The stand-alone BCMA system was implemented in one ward of a teaching hospital. The number of dispensing steps, dispensing time and potential dispensing errors (PDEs) were directly observed one month before and eight months after the intervention. Attitudes of pharmacy and nursing staff were assessed using a questionnaire (Likert scale) and interviews. Among 1291 and 471 drug items observed before and after the introduction of the technology respectively, the number of dispensing steps increased from five to eight and time (standard deviation) to dispense one drug item by one staff personnel increased from 0.8 (0.09) to 1.5 (0.12) min. Among 2828 and 471 drug items observed before and after the intervention respectively, the number of PDEs increased significantly (P<0.001). 'Procedural errors' and 'missing drug items' were the frequently observed PDEs in the after study. 'Perceived usefulness' and 'job relevance' of the technology decreased significantly (P=0.003 and P=0.004 respectively) among users who participated in the before (N=16) and after (N=16) questionnaires surveys. Among the interviewees, pharmacy staff felt that the system offered less benefit to the dispensing process (9/16). Nursing staff perceived the system as useful in improving the accuracy of drug administration (7/10). Implementing a stand-alone BCMA system may slow down and complicate the dispensing process. Nursing staff believe the stand-alone BCMA system could improve the drug administration process but pharmacy staff believes the technology would be more helpful if supported by computerised prescribing. However, periodical assessments are needed to identify weaknesses in the process after implementation, and all users should be educated on the benefits of using this technology. Copyright © 2014

  12. Microbiological quality of drinking water from dispensers in roadside restaurants of Bangladesh.

    PubMed

    Moniruzzaman, M; Akter, S; Islam, M A; Mia, Z

    2011-01-15

    The microbiological status of water from dispensers in different roadside restaurants of Dhaka city and Savar area was analyzed in this study. Seven samples from Dhaka and 8 samples of Savar were checked. The heterotrophic plate count was in a range of 1.0 x 10(3) CFU mL(-1) to 2.0 x 10(4) CFU mL(-1) (from new bottles), 1.0 x 10(3) to 1.5 x 10(4) CFU mL(-1) (after dispensation), and 1.5 x 10(3) CFU mL(-1) to 1.0 x l0(5) CFU mL(-1) (from serving glass). In several of the samples, the heterotrophic plate count was higher than the count in water from new bottle or after dispensation, suggesting added contamination from the serving glass. 80% of the samples were contaminated with total and fecal coliform bacteria, which render these waters unacceptable for human consumption. The samples were found to contain gram negative bacteria like E coli, Shigella sp., Klebsiella sp., Enterobacter sp., Pseudomonas sp., and Salmonella sp., which are potential pathogens and thus pose a serious threat to public health. This study elucidates the importance of monitoring the bottling companies and the restaurants and put them under strict regulations to prevent future outbreak of any water borne diseases caused by consumption of dispensed water.

  13. All dispenser printed flexible 3D structured thermoelectric generators

    NASA Astrophysics Data System (ADS)

    Cao, Z.; Shi, J. J.; Torah, R. N.; Tudor, M. J.; Beeby, S. P.

    2015-12-01

    This work presents a vertically fabricated 3D thermoelectric generator (TEG) by dispenser printing on flexible polyimide substrate. This direct-write technology only involves printing of electrodes, thermoelectric active materials and structure material, which needs no masks to transfer the patterns onto the substrate. The dimension for single thermoelectric element is 2 mm × 2 mm × 0.5 mm while the distance between adjacent cubes is 1.2 mm. The polymer structure layer was used to support the electrodes which are printed to connect the top ends of the thermoelectric material and ensure the flexibility as well. The advantages and the limitations of the dispenser printed 3D TEGs will also be evaluated in this paper. The proposed method is potential to be a low-cost and scalable fabrication solution for TEGs.

  14. Comparison of human and electronic observation for the measurement of compliance with hand hygiene.

    PubMed

    Filho, Miguel Almeida O; Marra, Alexandre R; Magnus, Thyago Pereira; Rodrigues, Rodrigo Dias; Prado, Marcelo; de Souza Santini, Tales Roberto; da Silva Victor, Elivane; Ishibe, Eder Issao; Pavão Dos Santos, Oscar Fernando; Edmond, Michael B

    2014-11-01

    Monitoring of hand hygiene is an important part of the improvement of hospital quality indicators. This study was prospectively performed over a 14-week (electronic observer) period from December 3, 2013-March 9, 2014, to evaluate hand hygiene compliance in an adult step-down unit. We compared electronic handwash counters with the application of radiofrequency identification (RFID - ZigBee; i-Healthsys, São Carlos, Brazil) (electronic observer), which counts each activation of the alcohol gel dispenser to direct observation (human observer) using the iScrub application. For the overall time period of simultaneous electronic and human observation, we found that the electronic observer identified 414 hand hygiene episodes, whereas the human observers identified 448 episodes. Therefore, we found 92% (95% confidence interval [CI], 90%-95%) overall concordance (414/448), with an intraclass correlation coefficient of .87 (95% CI, 0.77-0.92). Our RFID (ZigBee) system showed good accuracy (92%) and is a useful method to monitor hand hygiene compliance. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  15. Trends and changes in prescription opioid analgesic dispensing in Canada 2005–2012: an update with a focus on recent interventions

    PubMed Central

    2014-01-01

    Background Prescription opioid analgesic (POA) utilization has steeply increased globally, yet is far higher in established market economies than elsewhere. Canada features the world’s second-highest POA consumption rates. Following increases in POA-related harm, several POA control interventions have been implemented since 2010. Methods We examined trends and patterns in POA dispensing in Canada by province for 2005–2012, including a focus on the potential effects of interventions. Data on annual dispensing of individual POA formulations – categorized into ‘weak opioids’ and ‘strong opioids’ – from a representative sub-sample of 5,700 retail pharmacies across Canada (from IMS Brogan’s Compuscript) were converted into Defined Daily Doses (DDD), and examined intra- and inter-provincially as well as for Canada (total). Results Total POA dispensing – driven by strong opioids – increased across Canada until 2011; four provinces indicated decreases in strong opioid dispensing; seven provinces indicated decreases specifically in oxycodone dispensing, 2011–2012. The dispensing ratio weak/strong opioids decreased substantively. Major inter-provincial differences in POA dispensing levels and qualitative patterns of POA formulations dispensed persisted. Previous increasing trends in POA dispensing were reversed in select provinces 2011–2012, coinciding with POA-related interventions. Conclusions Further examinations regarding the sustained nature, drivers and consequences of the recent trend changes in POA dispensing – including possible ‘substitution effects’ for oxycodone reductions – are needed. PMID:24572005

  16. An evaluation of hand hygiene in an intensive care unit: Are visitors a potential vector for pathogens?

    PubMed

    Birnbach, David J; Rosen, Lisa F; Fitzpatrick, Maureen; Arheart, Kristopher L; Munoz-Price, L Silvia

    2015-01-01

    Patients in an intensive care unit (ICU) are frequently immunocompromised and might be highly susceptible to infection. Visitors to an ICU who do not adequately clean their hands could carry pathogenic organisms, resulting in risk to a vulnerable patient population. This observational study identifies pathogens carried on the hands of visitors into an ICU and investigates the effect of hand hygiene. Two observers, one stationed outside and one inside the ICU, evaluated whether visitors performed hand hygiene at any of the wall-mounted alcohol-based hand sanitizer dispensers prior to reaching a patient's room. Upon reaching a patient's room, the dominant hand of all of the participants was cultured. Of the 55 participating visitors, 35 did not disinfect their hands. Among the cultures of those who failed to perform hand hygiene, eight cultures grew Gram-negative rods and one grew methicillin-resistant Staphylococcus aureus. Of the cultures of the 20 individuals who performed hand hygiene, 14 (70%) had no growth on the cultures, and the remaining six (30%) showed only the usual skin flora. The visitors who do not perform hand hygiene might carry pathogens that pose a risk to ICU patients. Copyright © 2015 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  17. Comparison of the efficacy of dispensing granules with traditional decoction: a systematic review and meta-analysis

    PubMed Central

    Qiu, Ruijin; Zhang, Xiaoyu; Zhao, Chen; Li, Min

    2018-01-01

    Background Dispensing granules have been developed for about 20 years. However, whether they are as effective as the traditional decoction kept unclear. This systematic review and meta-analysis was made to assess the efficacy of dispensing granules compared with traditional decoction. Methods We searched four databases since their inception to 9th September in 2016. Two authors independently identified trials, extracted data and assessed risk of bias with Cochrane Reviewer’s Handbook 5.0. We conducted meta-analysis with RevMan 5.1.0 software for eligible and appropriate trials. Results In the end, 7,035 participants from 51 randomized controlled trials (RCTs) which compared dispensing granules with traditional decoction were included in this systematic review. There were 33 different kinds of diseases for investigation, of which 8 RCTs observed common cold, 4 RCTs observed migraine. For rheumatoid arthritis, insomnia and hypertension, there were 3 RCTs reported respectively. The last RCTs reported different kinds of diseases in one or two trials. The majority of trials were in low methodological quality. Thirty-eight (74.5%) RCTs showed that the efficacy of dispensing granules were similar with traditional decoction, 6 (11.8%) RCTs reported that the therapeutic efficacy of dispensing granules were significantly better than traditional decoction. We conducted meta-analysis for 4 trials investigating patients with migraine. The results showed that dispensing granules reduced headache frequency by about 1.03 attacks per month as compared to traditional decoction. No evidence was found in terms of migraine intensity and duration. Conclusions The low quality of RCTs and conflicting results made it difficult to draw a definite conclusion. In the future, it needs much more evidence to explore the efficacy and safety of dispensing granules. N-of-1 trials and fuzzy comprehensive evaluation methods may be better choices for assessing the efficacy of them than RCTs. PMID

  18. [Moving cupping at Hechelu combined with rubbing method for depression of diabetes mellitus].

    PubMed

    He, Lingna; Du, Ping; Shen, Zhifu; Wang, Xuan

    2016-03-01

    To compare the efficacy between moving cupping at Hechelu combined with rubbing method and western medication for depression of diabetes mellitus (DM). Two hundred and sixteen patients were randomly divided into an observation group and a control group, 108 cases in each group. Patients in the observation group were treated with moving cupping at Hechelu combined with rubbing method, once every: other day; six treatments were considered as one course, and totally two courses were given with an interval of: 4 days between courses. Patients in the control group were treated with oral administration of fluoxetine hydrochloride capsules, once a day for consecutive 4 weeks. The Hamilton depression scale (HAMD), self-rating depression scale (SDS) and TCM symptom score were measured before treatment, after the treatment and in follow-up visit one and a half months after treatment. The fasting blood glucose was tested before and after treatment. The glycosylated hemoglobin (HbA1c) was tested in the follow-up visit. The total effective rate was 90.9% (90/99) in the observation group, which was superior to 73.7% (70/95) in the control group (P < 0.05). After the treatment, HAMD, SDS and TCM symptom scores were all reduced apparently in the observation group and the control group (all P < 0.05). After the treatment and the follow-up visit, the TCM symptom score in the observation group was lower than that in the control group (P < 0.05). The levels of HbA1c and GLU were stable in the observation group, and were decreased compared with those before treatment; but the difference between the, two groups was not significant (P > 0.05). The Hechelu theory-based TCM treatment has better: efficacy for depression of diabetes mellitus than fluoxetine hydrochloride capsule, which has less adverse effects.

  19. Estimating dermal transfer from PCB-contaminated porous surfaces.

    PubMed

    Slayton, T M; Valberg, P A; Wait, A D

    1998-06-01

    Health risks posed by dermal contact with PCB-contaminated porous surfaces have not been directly demonstrated and are difficult to estimate indirectly. Surface contamination by organic compounds is commonly assessed by collecting wipe samples with hexane as the solvent. However, for porous surfaces, hexane wipe characterization is of limited direct use when estimating potential human exposure. Particularly for porous surfaces, the relationship between the amount of organic material collected by hexane and the amount actually picked up by, for example, a person's hand touch is unknown. To better mimic PCB pickup by casual hand contact with contaminated concrete surfaces, we used alternate solvents and wipe application methods that more closely mimic casual dermal contact. Our sampling results were compared to PCB pickup using hexane-wetted wipes and the standard rubbing protocol. Dry and oil-wetted samples, applied without rubbing, picked up less than 1% of the PCBs picked up by the standard hexane procedure; with rubbing, they picked up about 2%. Without rubbing, saline-wetted wipes picked up 2.5%; with rubbing, they picked up about 12%. While the nature of dermal contact with a contaminated surface cannot be perfectly reproduced with a wipe sample, our results with alternate wiping solvents and rubbing methods more closely mimic hand contact than the standard hexane wipe protocol. The relative pickup estimates presented in this paper can be used in conjunction with site-specific PCB hexane wipe results to estimate dermal pickup rates at sites with PCB-contaminated concrete.

  20. The role of pharmacists and emergency contraception: Are pharmacists' perceptions of emergency contraception predictive of their dispensing practices?

    PubMed

    Richman, Alice R; Daley, Ellen M; Baldwin, Julie; Kromrey, Jeff; O'Rourke, Kathleen; Perrin, Kay

    2012-10-01

    Pharmacists can play a critical role in the access to emergency contraception (EC). We assessed if knowledge and attitudes were predictive of EC dispensing among a statewide sample of Florida pharmacists, who have legal authority to refuse to dispense medications. In 2008, surveys were mailed to a random sample of 1264 pharmacists registered with the Florida Board of Pharmacy. Data from 272 pharmacists (22% response rate) were analyzed using bivariate and multivariate logistic regression. Fifty-six percent of respondents incorrectly answered that EC causes birth defects, and 46% replied that it causes abortion. Only 22% said that EC can be purchased in advance of need. Many felt uncomfortable dispensing to adolescents (61%) and men (58%). Knowledge about EC was the most important predictor of dispensing [odds ratio (OR)=1.57, 95% confidence interval (CI) 1.22-2.03]. In particular, pharmacists who reported that EC does not act as an abortifacient were more likely to dispense it (OR=4.64, 95% CI 2.15-10.00). Correct information about EC was the most important predictor of pharmacists' dispensing EC. To expand availability of EC, pharmacists will have to become better informed. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Brush seal bristle flexure and hard-rub characteristics

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1993-01-01

    The bristles of a 38.1-mm (1.5-in.) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in.) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in.) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in.) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in.) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping', and hot spots and streaks were found. With a smooth-plug rotor, post-test leakage increased 30 percent over pretest leakage.

  2. Brush seal low surface speed hard-rub characteristics

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1993-01-01

    The bristles of a 38.1-mm (1.5-in.) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in.) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in.) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in.) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in.) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping,' and hot spots and streaks were found. With a smooth-plug rotor, post-test leakage increased 30 percent over pretest leakage.

  3. Brush seal bristle flexure and hard-rub characteristics

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1992-01-01

    The bristles of a 38.1-mm (1.5-in) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping,' and hot spots and streaks were found. With a smooth-plug rotor post-test leakage increased 30 percent over pretest leakage.

  4. Brush seal bristle flexure and hard-rub characteristics

    NASA Astrophysics Data System (ADS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1992-08-01

    The bristles of a 38.1-mm (1.5-in) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping,' and hot spots and streaks were found. With a smooth-plug rotor post-test leakage increased 30 percent over pretest leakage.

  5. Brush seal bristle flexure and hard-rub characteristics

    NASA Astrophysics Data System (ADS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1993-10-01

    The bristles of a 38.1-mm (1.5-in.) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in.) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in.) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in.) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in.) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping', and hot spots and streaks were found. With a smooth-plug rotor, post-test leakage increased 30 percent over pretest leakage.

  6. Brush seal low surface speed hard-rub characteristics

    NASA Astrophysics Data System (ADS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1993-06-01

    The bristles of a 38.1-mm (1.5-in.) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in.) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in.) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in.) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in.) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping,' and hot spots and streaks were found. With a smooth-plug rotor, post-test leakage increased 30 percent over pretest leakage.

  7. 21 CFR 1304.50 - Disclosure requirements for Web sites of nonpharmacy practitioners that dispense controlled...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 9 2011-04-01 2011-04-01 false Disclosure requirements for Web sites of nonpharmacy practitioners that dispense controlled substances by means of the Internet. 1304.50 Section 1304... that dispense controlled substances by means of the Internet. For a Web site to identify itself as...

  8. 21 CFR 1304.50 - Disclosure requirements for Web sites of nonpharmacy practitioners that dispense controlled...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Disclosure requirements for Web sites of nonpharmacy practitioners that dispense controlled substances by means of the Internet. 1304.50 Section 1304... that dispense controlled substances by means of the Internet. For a Web site to identify itself as...

  9. A novel piezostack-driven jetting dispenser with corner-filleted flexure hinge and high-frequency performance

    NASA Astrophysics Data System (ADS)

    Bu, Zhenxiang; Lin, Siying; Huang, Xiang; Li, Anlin; Wu, Dezhi; Zhao, Yang; Luo, Zhiwei; Wang, Lingyun

    2018-07-01

    This paper presents a new jetting dispenser which is applicable to high-frequency microelectronic packaging. In order to achieve high frequency glue jetting and improve the stability of jetting dispensers, we redesign a novel displacement amplifying mechanism, and a new on–off valve jetting dispenser driven by piezoelectric actuators is developed. Firstly, the core part of this jetting dispenser—the displacement amplifying mechanism with a corner-filleted flexure hinge—is proposed and a comparison with the previous structure is carried out; then the characteristic dimensional parameters of the amplifying mechanism are determined by theoretical calculation and finite element analysis. Secondly, a prototype of the dispenser with the displacement amplifying mechanism is fabricated based on the determined parameters. We use a laser displacement sensor to test the displacement of the needle, and a maximum amplifying displacement output of 367 µm is obtained under an applied 200 V to the piezoelectric actuator, which is consistent with the simulation result and meets the requirement of high displacement output. Thirdly, we build an integrated testing system. Mixed glycerol/ethanol is chosen as the experimental dispensing glue, and the experiment and analysis of a droplet diameter are conducted. A higher jetting frequency of 400 Hz and a smaller droplet diameter of 525 µm are achieved with the glycerol/ethanol mixture, and the characteristics of consistency and temperature influencing the droplet diameter are verified by experiments.

  10. Guidelines for Mass Casualty Decontamination During a HAZMAT/Weapon of Mass Destruction Incident. Volumes 1 and 2 (Update)

    DTIC Science & Technology

    2013-08-01

    neutralization: 1. Physical removal involves mechanical action with techniques such as gentle fric- tion (such as rubbing with hands, soft non...sulfur mustard), using gen- tle friction, such as rubbing with hands, a soft cloth, or sponges is recommended to aid in re- moval of the contaminants...account for both initial mass decontamination and secondary de- contamination. Some examples include the use of colored rubber bands and specially de

  11. Wafer level fabrication of single cell dispenser chips with integrated electrodes for particle detection

    NASA Astrophysics Data System (ADS)

    Schoendube, Jonas; Yusof, Azmi; Kalkandjiev, Kiril; Zengerle, Roland; Koltay, Peter

    2015-02-01

    This work presents the microfabrication and experimental evaluation of a dispenser chip, designed for isolation and printing of single cells by combining impedance sensing and drop-on-demand dispensing. The dispenser chip features 50  ×  55 µm (width × height) microchannels, a droplet generator and microelectrodes for impedance measurements. The chip is fabricated by sandwiching a dry film photopolymer (TMMF) between a silicon and a Pyrex wafer. TMMF has been used to define microfluidic channels, to serve as low temperature (75 °C) bonding adhesive and as etch mask during 300 µm deep HF etching of the Pyrex wafer. Due to the novel fabrication technology involving the dry film resist, it became possible to fabricate facing electrodes at the top and bottom of the channel and to apply electrical impedance sensing for particle detection with improved performance. The presented microchip is capable of dispensing liquid and detecting microparticles via impedance measurement. Single polystyrene particles of 10 µm size could be detected with a mean signal amplitude of 0.39  ±  0.13 V (n=439 ) at particle velocities of up to 9.6 mm s-1 inside the chip.

  12. OsB 2 and RuB 2, ultra-incompressible, hard materials: First-principles electronic structure calculations

    NASA Astrophysics Data System (ADS)

    Chiodo, S.; Gotsis, H. J.; Russo, N.; Sicilia, E.

    2006-07-01

    Recently it has been reported that osmium diboride has an unusually large bulk modulus combined with high hardness, and consequently is a most interesting candidate as an ultra-incompressible and hard material. The electronic and structural properties of the transition metal diborides OsB 2 and RuB 2 have been calculated within the local density approximation (LDA). It is shown that the high hardness is the result of covalent bonding between transition metal d states and boron p states in the orthorhombic structure.

  13. Dispensing patterns for antidiabetic agents in New Zealand: are the guidelines being followed?

    PubMed

    Murray, Peter; Norris, Hew; Metcalfe, Scott; Betty, Bryan; Young, Vanessa; Locke, Bronwyn

    2017-11-10

    Type 2 diabetes mellitus (T2DM) is a significant public health issue in New Zealand. Effective management and glycaemic control is critical for reducing diabetes-related complications. Treatment guidelines are well established in New Zealand. Using dispensing data as a proxy for prescribing data, this paper aims to describe the pattern of first- and second-line antidiabetic agent (AA) dispensing for T2DM in New Zealand and assess adherence with treatment guidelines. Analysis of national dispensing data for AA medications using the Pharmaceutical Collection database from 2007/08 to 2015/16. Metformin monotherapy remains the most commonly prescribed first-line T2DM medication prescribed, accounting for 85% of initial agents prescribed. Sulfonylureas are the most common second-line agents used, accounting for 70% of all second-line agents. There is a high degree of adherence with the T2DM treatment guidelines in New Zealand.

  14. Electronic vending machines for dispensing rapid HIV self-testing kits: a case study.

    PubMed

    Young, Sean D; Klausner, Jeffrey; Fynn, Risa; Bolan, Robert

    2014-02-01

    This short report evaluates the feasibility of using electronic vending machines for dispensing oral, fluid, rapid HIV self-testing kits in Los Angeles County. Feasibility criteria that needed to be addressed were defined as: (1) ability to find a manufacturer who would allow dispensing of HIV testing kits and could fit them to the dimensions of a vending machine, (2) ability to identify and address potential initial obstacles, trade-offs in choosing a machine location, and (3) ability to gain community approval for implementing this approach in a community setting. To address these issues, we contracted a vending machine company who could supply a customized, Internet-enabled machine that could dispense HIV kits and partnered with a local health center available to host the machine onsite and provide counseling to participants, if needed. Vending machines appear to be feasible technologies that can be used to distribute HIV testing kits.

  15. Electronic vending machines for dispensing rapid HIV self-testing kits: A case study

    PubMed Central

    Young, Sean D.; Klausner, Jeffrey; Fynn, Risa; Bolan, Robert

    2014-01-01

    This short report evaluates the feasibility of using electronic vending machines for dispensing oral, fluid, rapid HIV-self testing kits in Los Angeles County. Feasibility criteria that needed to be addressed were defined as: 1) ability to find a manufacturer who would allow dispensing of HIV testing kits and could fit them to the dimensions of a vending machine, 2) ability to identify and address potential initial obstacles, trade-offs in choosing a machine location, and 3) ability to gain community approval for implementing this approach in a community setting. To address these issues, we contracted a vending machine company who could supply a customized, Internet-enabled machine that could dispense HIV kits and partnered with a local health center available to host the machine onsite and provide counseling to participants, if needed. Vending machines appear to be feasible technologies that can be used to distribute HIV testing kits. PMID:23777528

  16. Reformulation of controlled-release oxycodone and pharmacy dispensing patterns near the US-Canada border.

    PubMed

    Gomes, Tara; Paterson, J Michael; Juurlink, David N; Dhalla, Irfan A; Mamdani, Muhammad M

    2012-01-01

    In August 2010, a tamper-resistant formulation of controlled-release oxycodone (OxyContin-OP) was introduced in the United States but not in Canada. Our objective was to determine whether introduction of OxyContin-OP in the United States influenced prescription volumes for the original controlled-release oxycodone formulation (OxyContin) at Canadian pharmacies near the international border. We conducted a population-based, serial, cross-sectional study of prescriptions dispensed from pharmacies in the 3 cities with the highest volume of US-Canada border crossings in Ontario: Niagara Falls, Windsor and Sarnia. We analyzed data on all outpatient prescriptions for OxyContin dispensed by Canadian pharmacies near each border crossing between 2010 Apr. 1 and 2012 Feb. 29. We calculated and compared monthly prescription rates, adjusted per 1000 population and stratified by tablet strength. The number of tablets dispensed near 4 border crossings in the 3 Canadian cities remained stable over the study period. However, the rate of dispensing at pharmacies near the Detroit-Windsor Tunnel increased roughly 4-fold between August 2010 and February 2011, from 505 to 1969 tablets per 1000 population. By April 2011, following warnings to prescribers and pharmacies regarding drug-seeking behaviour, the dispensing rate declined to 1683 tablets per 1000 population in this area. By November 2011, the rate had returned to levels observed in early 2010. Our analyses suggest that 242 075 excess OxyContin tablets were dispensed near the Detroit-Windsor Tunnel between August 2010 and October 2011. Prescribing of the original formulation of controlled-release oxycodone rose substantially near a major international border crossing following the introduction of a tamper-resistant formulation in the United States. It is possible that the restriction of this finding to the area surrounding the Detroit-Windsor Tunnel reflects specific characteristics of this border crossing, including its high

  17. Population prevalence of high dose paracetamol in dispensed paracetamol/opioid prescription combinations: an observational study

    PubMed Central

    2012-01-01

    Background Paracetamol (acetaminophen) is generally considered a safe medication, but is associated with hepatotoxicity at doses above doses of 4.0 g/day, and even below this daily dose in certain populations. Methods The Nova Scotia Prescription Monitoring Program (NSPMP) in the Canadian province of Nova Scotia is a legislated organization that collects dispensing information on all out-of-hospital prescription controlled drugs dispensed for all Nova Scotia residents. The NSPMP provided data to track all paracetamol/opioids redeemed by adults in Nova Scotia, from July 1, 2005 to June 30, 2010. Trends in the number of adults dispensed these prescriptions and the numbers of prescriptions and tablets dispensed over this period were determined. The numbers and proportions of adults who filled prescriptions exceeding 4.0 g/day and 3.25 g/day were determined for the one-year period July 1, 2009 to June 30, 2010. Data were stratified by sex and age (<65 versus 65+). Results Both the number of prescriptions filled and the number of tablets dispensed increased over the study period, although the proportion of the adult population who filled at least one paracetamol/opioid prescription was lower in each successive one-year period. From July 2009 to June 2010, one in 12 adults (n = 59,197) filled prescriptions for over 13 million paracetamol/opioid tablets. Six percent (n = 3,786) filled prescriptions that exceeded 4.0 g/day and 18.6% (n = 11,008) exceeded 3.25 g/day of paracetamol at least once. These findings exclude non-prescription paracetamol and paracetamol–only prescribed medications. Conclusions A substantial number of individuals who redeem prescriptions for paracetamol/opioid combinations may be at risk of paracetamol-related hepatotoxicity. Healthcare professionals must be vigilant when prescribing and dispensing these medications in order to reduce the associated risks. PMID:22709372

  18. Can formalizing links among community health workers, accredited drug dispensing outlet dispensers, and health facility staff increase their collaboration to improve prompt access to maternal and child care? A qualitative study in Tanzania.

    PubMed

    Dillip, Angel; Kimatta, Suleiman; Embrey, Martha; Chalker, John C; Valimba, Richard; Malliwah, Mariam; Meena, John; Lieber, Rachel; Johnson, Keith

    2017-06-19

    In Tanzania, progress toward achieving the 2015 Millennium Development Goals for maternal and newborn health was slow. An intervention brought together community health workers, health facility staff, and accredited drug dispensing outlet (ADDO) dispensers to improve maternal and newborn health through a mechanism of collaboration and referral. This study explored barriers, successes, and promising approaches to increasing timely access to care by linking the three levels of health care provision. The study was conducted in the Kibaha district, where we applied qualitative approaches with in-depth interviews and focus group discussions. In-depth interview participants included retail drug shop dispensers (36), community health workers (45), and health facility staff members (15). We conducted one focus group discussion with district officials and four with mothers of newborns and children under 5 years old. Relationships among the three levels of care improved after the linkage intervention, especially for ADDO dispensers and health facility staff who previously had no formal communication pathway. The study participants perceptions of success included improved knowledge of case management and relationships among the three levels of care, more timely access to care, increased numbers of patients/customers, more meetings between community health workers and health facility staff, and a decrease in child and maternal mortality. Reported challenges included stock-outs of medicines at the health facility, participating ADDO dispensers who left to work in other regions, documentation of referrals, and lack of treatment available at health facilities on the weekend. The primary issue that threatens the sustainability of the intervention is that local council health management team members, who are responsible for facilitating the linkage, had not made any supervision visits and were therefore unaware of how the program was running. The study highlights the benefits of

  19. 21 CFR 1301.27 - Separate registration by retail pharmacies for installation and operation of automated dispensing...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Separate registration by retail pharmacies for....27 Separate registration by retail pharmacies for installation and operation of automated dispensing systems at long term care facilities. (a) A retail pharmacy may install and operate automated dispensing...

  20. 21 CFR 1301.27 - Separate registration by retail pharmacies for installation and operation of automated dispensing...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 9 2012-04-01 2012-04-01 false Separate registration by retail pharmacies for....27 Separate registration by retail pharmacies for installation and operation of automated dispensing systems at long term care facilities. (a) A retail pharmacy may install and operate automated dispensing...

  1. 21 CFR 1301.27 - Separate registration by retail pharmacies for installation and operation of automated dispensing...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 9 2014-04-01 2014-04-01 false Separate registration by retail pharmacies for....27 Separate registration by retail pharmacies for installation and operation of automated dispensing systems at long term care facilities. (a) A retail pharmacy may install and operate automated dispensing...

  2. 21 CFR 1301.27 - Separate registration by retail pharmacies for installation and operation of automated dispensing...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 9 2013-04-01 2013-04-01 false Separate registration by retail pharmacies for....27 Separate registration by retail pharmacies for installation and operation of automated dispensing systems at long term care facilities. (a) A retail pharmacy may install and operate automated dispensing...

  3. 21 CFR 1301.27 - Separate registration by retail pharmacies for installation and operation of automated dispensing...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 9 2011-04-01 2011-04-01 false Separate registration by retail pharmacies for....27 Separate registration by retail pharmacies for installation and operation of automated dispensing systems at long term care facilities. (a) A retail pharmacy may install and operate automated dispensing...

  4. Reducing bottom anti-reflective coating (BARC) defects: optimizing and decoupling the filtration and dispense process

    NASA Astrophysics Data System (ADS)

    Brakensiek, Nickolas L.; Martin, Gary; Simmons, Sean; Batchelder, Traci

    2006-03-01

    Semiconductor device manufacturing is one of the cleanest manufacturing operations that can be found in the world today. It has to be that way; a particle on a wafer today can kill an entire device, which raises the costs, and therefore reduces the profits, of the manufacturing company in two ways: it must produce extra wafers to make up for the lost die, and it has less product to sell. In today's state-of-the-art fab, everything is filtered to the lowest pore size available. This practice is fairly easy for gases because a gas molecule is very small compared to the pore size of the filter. Filtering liquids, especially photochemicals such as photoresists and BARCs, can be much harder because the molecules that form the polymers used to manufacture the photochemicals are approaching the filter pore size. As a result, filters may plug up, filtration rates may drop, pressure drops across the filter may increase, or a filter may degrade. These conditions can then cause polymer shearing, microbubble formation, gel particle formation, and BARC chemical changes to occur before the BARC reaches the wafer. To investigate these possible interactions, an Entegris(R) IntelliGen(R) pump was installed on a TEL Mk8 TM track to see if the filtration process would have an effect on the BARC chemistry and coating defects. Various BARC chemicals such as DUV112 and DUV42P were pumped through various filter media having a variety of pore sizes at different filtration rates to investigate the interaction between the dispense process and the filtration process. The IntelliGen2 pump has the capability to filter the BARC independent of the dispense process. By using a designed experiment to look at various parameters such as dispense rate, filtration rate, and dispense volume, the effects of the complete pump system can be learned, and appropriate conditions can be applied to yield the cleanest BARC coating process. Results indicate that filtration rate and filter pore size play a

  5. The knowledge of emergency contraception and dispensing practices of Patent Medicine Vendors in South West Nigeria.

    PubMed

    Fayemi, Mojisola M; Oduola, Olufemi L; Ogbuji, Queen C; Osinowo, Kehinde A; Oyewo, Adejoke E; Osiberu, Olabimpe M

    2010-09-01

    Patent Medicine Vendors (PMVs) can play a critical role in increasing access to emergency contraceptive pills (ECPs) in developing countries, but few studies have examined their knowledge and dispensing practices. Using cluster sampling, the authors selected and interviewed 97 PMVs (60.8 per cent female) in Oyo and Ogun States of Nigeria to assess their knowledge, dispensing practices, and referral for ECPs. About one-third (27.8 per cent) of respondents were not aware of ECPs, and only half knew that ECPs could prevent pregnancy. Forty per cent had ever dispensed ECPs. Reasons proffered by those who do not dispense ECPs included barriers from the State Ministry of Health, police, other regulatory agencies, and religious beliefs. Only 50.5 per cent have referral arrangements for clients. Strategies to increase access to ECPs through PMVs include training on counseling techniques and referral, effective government regulation, and community involvement. Where unsafe abortion is a major cause of maternal mortality, these strategies offer protection for many women in the future.

  6. College Cafeteria Signage Increases Water Intake but Water Position on the Soda Dispenser Encourages More Soda Consumption.

    PubMed

    Montuclard, Astrid Linn; Park-Mroch, Jennifer; O'Shea, Amy M J; Wansink, Brian; Irvin, Jill; Laroche, Helena H

    2017-10-01

    To evaluate the effects of improved water location visibility and water dispenser position on the soda dispenser on undergraduate students' beverage choices. Two focus groups with pilot intervention surveys before and after, adding a small sign above the soda dispensers' water button for 6 weeks in a large US university's all-you-can-eat, prepaid dining hall (measured with chi-square tests and logistic and ordinal logistic regression). Focus groups included 15 students. Survey participants included 357 students before and 301 after the intervention. After the intervention, more students reported ever having drunk water with the meal (66.4% to 77.0%; P = .003) and water consumption frequency increased (P = .005). Postintervention, the odds of drinking water increased by 1.57. Preference for other drinks was the main reason for not drinking water. A total of 59% of students had ever changed their preference from water to soda. The clear indication of the water's location increased students' reported water consumption. Further investigation is needed into how a non-independent water dispenser influences students' beverage choice. Clearly labeled, independent water dispensers are recommended. Copyright © 2017 Society for Nutrition Education and Behavior. All rights reserved.

  7. Surface contamination of counting tools after mock dispensing of cyclophosphamide in a simulated outpatient pharmacy.

    PubMed

    Chaffee, Bruce W; Lander, Michael J; Christen, Catherine; Redic, Kimberly A

    2018-01-01

    Purpose The primary aim was to determine if dispensing of cyclophosphamide tablets resulted in accumulated residue on pharmacy counting tools during a simulated outpatient dispensing process. Secondary objectives included determining if cyclophosphamide contamination exceeded a defined threshold level of 1 ng/cm 2 and if a larger number of prescriptions dispensed resulted in increased contamination. Methods Mock prescriptions of 40 cyclophosphamide 50 mg tablets were counted on clean trays in three scenarios using a simulated outpatient pharmacy after assaying five cleaned trays as controls. The three scenarios consisted of five simulated dispensings of one, three, or six prescriptions dispensed per scenario. Wipe samples of trays and spatulas were collected and assayed for all trays, including the five clean trays used as controls. Contamination was defined as an assayed cyclophosphamide level at or above 0.001 ng/cm 2 and levels above 1 ng/cm 2 were considered sufficient to cause risk of human uptake. Mean contamination for each scenario was calculated and compared using one-way analysis of variance. P-values of < 0.05 implied significance. Results Mean cyclophosphamide contamination on trays used to count one, three, and six cyclophosphamide prescriptions was 0.51 ± 0.10 (p=0.0003), 1.02 ± 0.10 (p < 0.0001), and 1.82 ± 0.10 ng/cm 2 (p < 0.0001), respectively. Control trays did not show detectable cyclophosphamide contamination. Increasing the number of prescriptions dispensed from 1 to 3, 1 to 6, and 3 to 6 counts increased contamination by 0.51 ± 0.15 (p = 0.0140), 1.31 + 0.15 (p < 0.0001), and 0.80 ± 0.15 ng/cm 2 (p = 0.0004), respectively. Conclusion Dispensing one or more prescriptions of 40 cyclophosphamide 50 mg tablets contaminates pharmacy counting tools, and an increased number of prescriptions dispensed correlates with increased level of contamination. Counting out three or more

  8. The effect of hand hygiene on illness rate among students in university residence halls.

    PubMed

    White, Cindy; Kolble, Robin; Carlson, Rebecca; Lipson, Natasha; Dolan, Mike; Ali, Yusuf; Cline, Mojee

    2003-10-01

    Several studies have indicated a connection between hand sanitization and infection control in numerous settings such as extended care facilities, schools, and hospitals. The purpose of this study was to assess the effectiveness of both a hand-hygiene message campaign and the use of an alcohol gel hand sanitizer in decreasing the incidence of upper-respiratory illness among students living in university residence halls. This study involved a total of 430 students recruited from 4 residence halls during the fall semester at the University of Colorado at the Boulder campus. Dormitories were paired into control and product groups. In the product groups, alcohol gel hand-sanitizer dispensers were installed in every room, bathroom, and dining hall. The data were statistically analyzed for the differences between product and control groups in reported symptoms, illness rates, and absenteeism from classes. The overall increase in hand-hygiene behavior and reduction in symptoms, illness rates, and absenteeism between the product group and control group was statistically significant. Reductions in upper respiratory-illness symptoms ranged from 14.8% to 39.9%. Total improvement in illness rate was 20%. The product group had 43% less missed school/work days. Hand-hygiene practices were improved with increased frequency of handwashing through increasing awareness of the importance of hand hygiene, and the use of alcohol gel hand sanitizer in university dormitories. This resulted in fewer upper respiratory-illness symptoms, lower illness rates, and lower absenteeism.

  9. Effect of Bar-code Technology on the Incidence of Medication Dispensing Errors and Potential Adverse Drug Events in a Hospital Pharmacy

    PubMed Central

    Poon, Eric G; Cina, Jennifer L; Churchill, William W; Mitton, Patricia; McCrea, Michelle L; Featherstone, Erica; Keohane, Carol A; Rothschild, Jeffrey M; Bates, David W; Gandhi, Tejal K

    2005-01-01

    We performed a direct observation pre-post study to evaluate the impact of barcode technology on medication dispensing errors and potential adverse drug events in the pharmacy of a tertiary-academic medical center. We found that barcode technology significantly reduced the rate of target dispensing errors leaving the pharmacy by 85%, from 0.37% to 0.06%. The rate of potential adverse drug events (ADEs) due to dispensing errors was also significantly reduced by 63%, from 0.19% to 0.069%. In a 735-bed hospital where 6 million doses of medications are dispensed per year, this technology is expected to prevent about 13,000 dispensing errors and 6,000 potential ADEs per year. PMID:16779372

  10. Making change easy: A peer-to-peer guide on transitioning to new hand hygiene products.

    PubMed

    Amirov, Chingiz M; Candon, Heather L; Jacob, Latha

    2017-01-01

    This report summarizes our experiences planning and implementing the transition to a new commercial line of hand hygiene products and their dispensing systems in a large academic health care facility in Toronto, Canada. Our lessons learned are organized into a practical guide made available in 2 different formats: this article and an illustrated peer-to-peer guide (http://www.baycrest.org/wp-content/uploads/HCE-PROG-HH_HighQuality.pdf). Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  11. Centrifugal multiplexing fixed-volume dispenser on a plastic lab-on-a-disk for parallel biochemical single-end-point assays

    PubMed Central

    La, Moonwoo; Park, Sang Min; Kim, Dong Sung

    2015-01-01

    In this study, a multiple sample dispenser for precisely metered fixed volumes was successfully designed, fabricated, and fully characterized on a plastic centrifugal lab-on-a-disk (LOD) for parallel biochemical single-end-point assays. The dispenser, namely, a centrifugal multiplexing fixed-volume dispenser (C-MUFID) was designed with microfluidic structures based on the theoretical modeling about a centrifugal circumferential filling flow. The designed LODs were fabricated with a polystyrene substrate through micromachining and they were thermally bonded with a flat substrate. Furthermore, six parallel metering and dispensing assays were conducted at the same fixed-volume (1.27 μl) with a relative variation of ±0.02 μl. Moreover, the samples were metered and dispensed at different sub-volumes. To visualize the metering and dispensing performances, the C-MUFID was integrated with a serpentine micromixer during parallel centrifugal mixing tests. Parallel biochemical single-end-point assays were successfully conducted on the developed LOD using a standard serum with albumin, glucose, and total protein reagents. The developed LOD could be widely applied to various biochemical single-end-point assays which require different volume ratios of the sample and reagent by controlling the design of the C-MUFID. The proposed LOD is feasible for point-of-care diagnostics because of its mass-producible structures, reliable metering/dispensing performance, and parallel biochemical single-end-point assays, which can identify numerous biochemical. PMID:25610516

  12. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2500...

  13. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2500...

  14. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2500...

  15. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2500...

  16. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2500...

  17. [Consumption of hand-hygiene products in health establishments in the west of France].

    PubMed

    Branger, B; Senechal, H; Bataillon, S; Ertzscheid, M A; Baron, R; Borgey, F; Thibon, P; Van Der Mee, N; Girard, N; Wiesel, M; Avril, C; Coulomb, F; Chaperon, J; Lejeune, B

    2005-06-01

    The study had for aim to investigate hand hygiene product use in French hospitals between 2000 and 2003. A questionnaire was sent in 2002 and 2 more in 2003 and 2004 (for 2000 to 2003) requiring data on type of hospital, number of beds, staff members, admissions and patient-day, litres of mild soap, antiseptic soap and alcohol-based rub used and price per litre. Indices were calculated accordingly. 574 hospitals answered over the 4 year period (average 143 per year) representing an average of 50 000 beds/year, 80 000 full-time staff positions, 1.2 million admissions and 16 millions patient-days. The median consumption of mild soap was 3.8 l per bed, 2.7 l per staff member, 2.4 l per 100 admissions, and 10.6 ml per patient-day. The median consumption of antiseptic soap was 1 l per bed, 0.8 l per staff member, 4.8 l per 100 admissions, and 3.2 ml per patient-day. The median consumption of alcohol-based rub (HAS) was 0.3 l per bed, 0.3 l per staff-member, 1.5 l per admission, and 0.9 l per patient-day. Between 2000 and 2003, HAS use significantly increased from 69 to 88% (a relative increase of 31%) and the median consumption increased from 0.5 ml to 1.5 ml per patient-day. 370 fully completed grids gave a number of 7 opportunities per patient-day with less than 1 for HAS. The best indicator for an infection control practitioners is the quantity of alcohol-based solution in ml/patient-day and HAS per patient-day is the reference.

  18. Effective reprocessing of reusable dispensers for surface disinfection tissues – the devil is in the details

    PubMed Central

    Kampf, Günter; Degenhardt, Stina; Lackner, Sibylle; Ostermeyer, Christiane

    2014-01-01

    Background: It has recently been reported that reusable dispensers for surface disinfection tissues may be contaminated, especially with adapted Achromobacter species 3, when products based on surface-active ingredients are used. Fresh solution may quickly become recontaminated if dispensers are not processed adequately. Methods: We evaluated the abilities of six manual and three automatic processes for processing contaminated dispensers to prevent recolonisation of a freshly-prepared disinfectant solution (Mikrobac forte 0.5%). Dispensers were left at room temperature for 28 days. Samples of the disinfectant solution were taken every 7 days and assessed quantitatively for bacterial contamination. Results: All automatic procedures prevented recolonisation of the disinfectant solution when a temperature of 60–70°C was ensured for at least 5 min, with or without the addition of chemical cleaning agents. Manual procedures prevented recontamination of the disinfectant solution when rinsing with hot water or a thorough cleaning step was performed before treating all surfaces with an alcohol-based disinfectant or an oxygen-releaser. Other cleaning and disinfection procedures, including the use of an alcohol-based disinfectant, did not prevent recolonisation. Conclusions: These results indicate that not all processes are effective for processing reusable dispensers for surface-disinfectant tissues, and that a high temperature during the cleaning step or use of a biofilm-active cleaning agent are essential. PMID:24653973

  19. Photoemission experiments of a large area scandate dispenser cathode

    NASA Astrophysics Data System (ADS)

    Zhang, Huang; Liu, Xing-guang; Chen, Yi; Chen, De-biao; Jiang, Xiao-guo; Yang, An-min; Xia, Lian-sheng; Zhang, Kai-zhi; Shi, Jin-shui; Zhang, Lin-wen

    2010-09-01

    A 100-mm-diameter scandate dispenser cathode was tested as a photocathode with a 10 ns Nd:YAG laser (266 nm) on an injector test stand for linear induction accelerators. This thermionic dispenser cathode worked at temperatures ranging from room temperature to 930 °C (below or near the thermionic emission threshold) while the vacuum was better than 4×10 -7 Torr. The laser pulse was synchronized with a 120 ns diode voltage pulse stably and they were in single pulse mode. Emission currents were measured by a Faraday cup. The maximum peak current collected at the anode was about 100 A. The maximum quantum efficiency measured at low laser power was 2.4×10 -4. Poisoning effect due to residual gas was obvious and uninterrupted heating was needed to keep cathode's emission capability. The cathode was exposed to air one time between experiments and recovered after being reconditioned. Photoemission uniformity of the cathode was also explored by changing the laser spot's position.

  20. The effect of the color red on consuming food does not depend on achromatic (Michelson) contrast and extends to rubbing cream on the skin.

    PubMed

    Bruno, Nicola; Martani, Margherita; Corsini, Claudia; Oleari, Claudio

    2013-12-01

    Recent literature suggests that individuals may consume less food when this is served on red plates. We explored this intriguing effect in three experiments. Independent groups of participants were presented with constant amounts of popcorns, chocolate chips, or moisturizing cream, on red, blue, or white plates. They were asked to sample the foods (by tasting them) or the cream (by rubbing it on the hand and forearm) as they wished and to complete mock "sensory analysis" questionnaires. Results confirmed that red plates reduce taste-related consumption and extended this effect to the touch-related consumption of moisturizing cream. Suggesting that the effect was not due to a decrease in the consciously experienced appeal of products on red plates, overall appreciation of the foods or cream did not differ according to plate color. After careful photometric measures of the materials used for each food-plate pairing, we determined that food and cream consumption was not predicted by Michelson (achromatic) contrast. Although the origin of the intriguing effect of the color red on consumption remains unclear, our results may prove useful to future potential explanations. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Exceptional circumstance drug dispensing: history and expenditures of the Brazilian Ministry of Health.

    PubMed

    Carias, Claudia Mezleveckas; Vieira, Fabíola Sulpino; Giordano, Carlos V; Zucchi, Paola

    2011-04-01

    To describe the technical aspects of the Exceptional Circumstance Drug Dispensing Program of the Brazilian Ministry of Health, especially with respect to the cost of dispensed medication. Technical information was obtained from the ordinances that regulate the Program. Expenditure from 2000 to 2007 was obtained from the Sistema Único de Saúde's (Unified Healthcare System) Outpatient Information System. All drugs dispensed between 1993 and 2009 and the amount and cost of each procedure were evaluated, based on information from the high-complexity procedure authorization of each of the country's states. The Program changed with the increase in the number of pharmacological agents and presentations distributed by, and the number of diseases contemplated in the program. In 1993, the program distributed 15 pharmacological agents in 31 distinct presentations. This number increased to 109 agents in 243 presentations in 2009. Total Ministry of Health expenditure with medications was R$1,410,181,600.74 in 2007, almost twice the amount spent in 2000, R$684,975,404.43. Diseases whose expenditure increased in the period included chronic renal insufficiency, transplantation, and hepatitis C. The Exceptional Circumstance Drug Dispensing Program is in constant transformation, aimed at building instruments and strategies that can ensure and expand access to medication among the population. Alternatives should be sought to decrease the financial impact of the Program to a level that does not impact other sectors of the health care system, given the high cost associated with novel interventions.

  2. How much do Blantyre dispensers in hospital and community pharmacies know about the new malaria treatment guidelines?

    PubMed

    Minyaliwa, Collins; Bandawe, Chiwoza; Mwale, Richman James

    2012-03-01

    To determine the knowledge of dispensers in hospital and community pharmacies within Blantyre on new malaria treatment guidelines. An interviewer administered questionnaire was used for data collection and the questions focused on the knowledge of dispensers on the new malaria treatment guidelines and whether the subjects were involved in the preparation or implementation of the guidelines or had undertaken any training on how to dispense the new anti-malarial medicines. None of the participants had been involved in the preparation of the treatment guidelines and only 45.5% of the participants had undertaken the pre-implementation training. Ninety percent of the interviewees had knowledge concerning the appropriate treatment of malaria in pregnancy. However, as many as 90.9% of the interviewed participants could not mention any possible five or more side-effects of LA and only 13.6% knew how to properly manage the possible effects. Only 27.3% knew the correct dose regimen of LA and none of them knew the condition of taking LA with a fatty meal for improved absorption. Lack of involvement of the pharmaceutical personnel working in hospital and community pharmacies, from the preparation of new malaria treatment guidelines to their implementation, inadequate training and qualifications of the dispensing personnel contributed to their lack of knowledge and skill on how to rationally dispense the medicines. Pharmaceutical personnel dispensing in the pharmacies need to be involved from the beginning in the preparation of treatment guidelines. Adequate training should be provided and followed by continuous professional education.

  3. Influence of community pharmacists׳ attitudes on antibiotic dispensing behavior: a cross-sectional study in Portugal.

    PubMed

    Roque, Fátima; Soares, Sara; Breitenfeld, Luiza; Figueiras, Adolfo; Herdeiro, Maria Teresa

    2015-01-01

    The emergence of microbial resistance is widely associated with inappropriate antibiotic use. Self-medication with antibiotics acquired directly from pharmacies without a medical prescription has been reported by several European countries as being an important cause of such inappropriate use. The goal of this study was to identify and evaluate community pharmacists׳ attitudes toward and knowledge of antibiotics and microbial resistance and to assess what influence, if any, these attitudes might have on their propensity to dispense unprescribed antibiotics. We conducted a cross-sectional study covering all community pharmacists registered with the Official College of Pharmacists in Portugal׳s Central Region. A self-administered questionnaire on attitudes toward microbial resistance and antibiotic use was mailed to 1197 pharmacists. Responses ranged from 0 (total disagreement) to 10 (total agreement). Logistic regression was used to model the association between respondents׳ attitudes and their propensity to dispense antibiotics without an earlier medical prescription. The overall response rate was 64.8%. Agreement with the dispensing of unprescribed antibiotics was highest in the case of dental diseases and ailments, followed by urinary tract infections. Although none of the sociodemographic data were associated with a propensity to dispense antibiotics without a medical prescription, the attitudes shown to be significantly associated with this propensity were complacency about patients, responsibility of others, and precaution or fear. Because the attitudes of community pharmacists can influence their readiness to dispense unprescribed antibiotics, educational interventions addressing such attitudes should be implemented to improve antibiotic use. Copyright © 2015 Elsevier HS Journals, Inc. All rights reserved.

  4. Effectiveness of multifaceted educational programme to reduce antibiotic dispensing in primary care: practice based randomised controlled trial

    PubMed Central

    Simpson, Sharon A; Dunstan, Frank; Rollnick, Stephen; Cohen, David; Gillespie, David; Evans, Meirion R; health, senior lecturer in epidemiology and public; Alam, M Fasihul; Bekkers, Marie-Jet; Evans, John; Moore, Laurence; Howe, Robin; Hayes, Jamie; Hare, Monika; Hood, Kerenza

    2012-01-01

    Objective To evaluate the effectiveness and costs of a multifaceted flexible educational programme aimed at reducing antibiotic dispensing at the practice level in primary care. Design Randomised controlled trial with general practices as the unit of randomisation and analysis. Clinicians and researchers were blinded to group allocation until after randomisation. Setting 68 general practices with about 480 000 patients in Wales, United Kingdom. Participants 34 practices were randomised to receive the educational programme and 34 practices to be controls. 139 clinicians from the intervention practices and 124 from control practices had agreed to participate before randomisation. Practice level data covering all the clinicians in the 68 practices were analysed. Interventions Intervention practices followed the Stemming the Tide of Antibiotic Resistance (STAR) educational programme, which included a practice based seminar reflecting on the practices’ own dispensing and resistance data, online educational elements, and practising consulting skills in routine care. Control practices provided usual care. Main outcome measures Total numbers of oral antibiotic items dispensed for all causes per 1000 practice patients in the year after the intervention, adjusted for the previous year’s dispensing. Secondary outcomes included reconsultations, admissions to hospital for selected causes, and costs. Results The rate of oral antibiotic dispensing (items per 1000 registered patients) decreased by 14.1 in the intervention group but increased by 12.1 in the control group, a net difference of 26.1. After adjustment for baseline dispensing rate, this amounted to a 4.2% (95% confidence interval 0.6% to 7.7%) reduction in total oral antibiotic dispensing for the year in the intervention group relative to the control group (P=0.02). Reductions were found for all classes of antibiotics other than penicillinase-resistant penicillins but were largest and significant individually for

  5. [Quality indicators in the storage and dispensing process in a Hospital Pharmacy].

    PubMed

    Rabuñal-Álvarez, M T; Calvin-Lamas, M; Feal-Cortizas, B; Martínez-López, L M; Pedreira-Vázquez, I; Martín-Herranz, M I

    2014-01-01

    To establish indicators for the evaluation of the quality of the storage and dispensing processes related to semiautomatic vertical (SAVCS) and horizontal (SAHCS) carousel systems. Descriptive observational study conducted between January-December 2012. Definition of quality indicators, a target value is established and an obtained value is calculated for 2012. Five quality indicators in the process of storage and dispensing of drugs were defined and calculated: indicator 1, error filling unidose trolleys: target (<1.67%), obtained (1.03%); indicator 2, filling accuracy unidose trolleys by using an SAVCS: target (<15%), obtained (11.5%); indicator 3, reliability of drug inventory in the process of drug entries using an SAHCS: target (<15%), obtained (6.53%); indicator 4, reliability of drug inventory in the picking process of orders replacement stock of clinical units using an SAHCS: target (<10%), obtained (1.97%); indicator 5, accuracy of the picking process of drug orders using an SAHCS: target (<10%), obtained (10.41%). Establishing indicators has allowed the quality in terms of safety, precision and reliability of semiautomatic systems for storage and dispensing drugs to be assessed. Copyright © 2014 SECA. Published by Elsevier Espana. All rights reserved.

  6. Influence of technique used to attach the infusion set to peristaltic finger smart-pumps on dispensing time: an experimental study.

    PubMed

    Umemura, Masayuki; Maegawa, Kanae; Arai, Daichi; Shigeno, Katsuro; Wakiya, Yoshifumi

    2018-01-01

    Infusion sets designed for peristaltic finger smart pumps (PFSPs) are necessary for the pumps' accurate handling. We previously found that medication dispensing is occasionally incomplete following the calculated infusion time when using certain combinations of PFSPs and infusion sets at a Japanese hospital. Thus, in this study, we investigated the cause of this observed delay by determining the effect of infusion set attachment technique on dispensing time using a combination of three kinds of PFSPs and five kinds of polyvinyl chloride (PVC) and polybutadiene (PB) infusion sets. PFSPs with their exclusive infusion sets were used. The PVC and PB infusion sets were either not stretched or stretched to 1-3 cm and attached to the PFSP's liquid delivery system. PFSP dispensing rates were set at 25-400 mL/h. The primary outcome was the time required to dispense 100 mL of saline in a volumetric flask. The complete dispensing time correlated with the input time for all equipment combinations when the infusion sets were not stretched before attachment to the PFSP (R 2  = 0.9998-1.0000). When stretched, the complete dispensing time was longer than the input time ( P  < 0.01-0.05, analysis of variance with Tukey-Kramer multiple comparisons). The maximum dispensing time extension ratio for the PVC and PB infusion sets was 141.8% and 113.0%, respectively. Certain attachment techniques for infusion sets can adversely prolong drug dispensing time. As such, pharmacists should provide medical staff with information about the devices used to administer drugs, as well as about the drugs themselves.

  7. Adherence to hand hygiene protocol by clinicians and medical students at Queen Elizabeth Central Hospital, Blantyre-Malawi.

    PubMed

    Kalata, N L; Kamange, L; Muula, A S

    2013-06-01

    , with forgetfulness and negligence being the major contributing factors. A hospital-wide multifaceted program aiming at clinicians and students education, adoption of alcohol based hand rubs as a primary formulation, production of colored poster reminders and encouraging role modeling of junior practitioners by senior practitioners can help improve compliance to hand hygiene.

  8. Pharmacists’ experiences with dispensing opioids

    PubMed Central

    Kahan, Meldon; Wilson, Lynn; Wenghofer, Elizabeth Francis; Srivastava, Anita; Resnick, Anne; Janecek, Eva; Sheehan, Carolynn

    2011-01-01

    Abstract Objective To explore pharmacists’ beliefs, practices, and experiences regarding opioid dispensing. Design Mailed survey. Setting The province of Ontario. Participants A total of 1011 pharmacists selected from the Ontario College of Pharmacists’ registration list. Main outcome measures Pharmacists’ experiences with opioid-related adverse events (intoxication and aberrant drug-related behaviour) and their interactions with physicians. Results A total of 652 pharmacists returned the survey, for a response rate of 64%. Most (86%) reported that they were concerned about several or many of their patients who were taking opioids; 36% reported that at least 1 patient was intoxicated from opioids while visiting their pharmacies within the past year. Reasons for opioid intoxication included the patient taking more than prescribed (84%), the patient using alcohol or sedating drugs along with the opioid (69.9%), or the prescribed dose being too high (34%). Participants’ most common concerns in the 3 months before the survey were patients coming in early for prescription refills, suspected double-doctoring, and requests for replacement doses for lost medication (reported frequently by 39%, 12%, and 16% of respondents, respectively). Pharmacists were concerned about physician practices, such as prescribing benzodiazepines along with opioids. Pharmacists reported difficulty in reaching physicians directly by telephone (43%), and indicated that physicians frequently did not return their calls promptly (28%). The strategies rated as most helpful for improving opioid dispensing were a provincial prescription database and opioid prescribing guidelines. Conclusion Pharmacists commonly observe opioid intoxication and aberrant drug-related behaviour in their patients but have difficulty communicating their concerns to physicians. System-wide strategies are urgently needed to improve the safety of opioid prescribing and to enhance communication between physicians and

  9. Implementation and optimization of automated dispensing cabinet technology.

    PubMed

    McCarthy, Bryan C; Ferker, Michael

    2016-10-01

    A multifaceted automated dispensing cabinet (ADC) optimization initiative at a large hospital is described. The ADC optimization project, which was launched approximately six weeks after activation of ADCs in 30 patient care unit medication rooms of a newly established adult hospital, included (1) adjustment of par inventory levels (desired on-hand quantities of medications) and par reorder quantities to reduce the risk of ADC supply exhaustion and improve restocking efficiency, (2) expansion of ADC "common stock" (medications assigned to ADC inventories) to increase medication availability at the point of care, and (3) removal of some infrequently prescribed medications from ADCs to reduce the likelihood of product expiration. The purpose of the project was to address organizational concerns regarding widespread ADC medication stockouts, growing reliance on cart-fill medication delivery systems, and suboptimal medication order turnaround times. Leveraging of the ADC technology platform's reporting functionalities for enhanced inventory control yielded a number of benefits, including cost savings resulting from reduced pharmacy technician labor requirements (estimated at $2,728 annually), a substantial reduction in the overall weekly stockout percentage (from 3.2% before optimization to 0.5% eight months after optimization), an improvement in the average medication turnaround time, and estimated cost avoidance of $19,660 attributed to the reduced potential for product expiration. Efforts to optimize ADCs through par level optimization, expansion of common stock, and removal of infrequently used medications reduced pharmacy technician labor, decreased stockout percentages, generated opportunities for cost avoidance, and improved medication turnaround times. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  10. Control method for high-pressure hydrogen vehicle fueling station dispensers

    DOEpatents

    Kountz, Kenneth John; Kriha, Kenneth Robert; Liss, William E.

    2006-06-13

    A method for quick filling a vehicle hydrogen storage vessel with hydrogen, the key component of which is an algorithm used to control the fill process, which interacts with the hydrogen dispensing apparatus to determine the vehicle hydrogen storage vessel capacity.

  11. Robotic dispensing of composite scaffolds and in vitro responses of bone marrow stromal cells.

    PubMed

    Hong, Seok-Jung; Jeong, Ishik; Noh, Kyung-Tae; Yu, Hye-Sun; Lee, Gil-Su; Kim, Hae-Won

    2009-09-01

    The development of bioactive scaffolds with a designed pore configuration is of particular importance in bone tissue engineering. In this study, bone scaffolds with a controlled pore structure and a bioactive composition were produced using a robotic dispensing technique. A poly(epsilon-caprolactone) (PCL) and hydroxyapatite (HA) composite solution (PCL/HA = 1) was constructed into a 3-dimensional (3D) porous scaffold by fiber deposition and layer-by-layer assembly using a computer-aided robocasting machine. The in vitro tissue cell compatibility was examined using rat bone marrow stromal cells (rBMSCs). The adhesion and growth of cells onto the robotic dispensed scaffolds were observed to be limited by applying the conventional cell seeding technique. However, the initially adhered cells were viable on the scaffold surface. The alkaline phosphatase activity of the cells was significantly higher on the HA-PCL than on the PCL and control culture dish, suggesting that the robotic dispensed HA-PCL scaffold should stimulate the osteogenic differentiation of rBMSCs. Moreover, the expression of a series of bone-associated genes, including alkaline phosphatase and collagen type I, was highly up-regulated on the HA-PCL scaffold as compared to that on the pure PCL scaffold. Overall, the robotic dispensed HA-PCL is considered to find potential use as a bioactive 3D scaffold for bone tissue engineering.

  12. A model "go-kit" for use at Strategic National Stockpile Points of Dispensing.

    PubMed

    May, Larissa; Cote, Timothy; Hardeman, Bernard; Gonzalez, Gabriela R; Adams, Sherry B; Blair, Roderick K; Pane, Gregg

    2007-01-01

    The Strategic National Stockpile (SNS) is a national repository of pharmaceuticals and other medical supplies forseeably needed during a medical disaster. In the event of SNS deployment, state and local public health authorities must be prepared to receive, distribute, and dispense the materials. We propose a cache of supplies, termed the "POD go-kit," prepared in advance and locally available prior to the establishment of Points of Dispensing (POD) for SNS material. Characteristics of the preassembled go-kit are its multiplicity of use, ease of storage and transportation, minimal redundancy with SNS material, and packaging in a manner consistent with POD function. The POD go-kit is assembled into 4 separate "subkits": administrative supplies, patient routing supplies, dispensing supplies, and POD staff protection supplies. Incorporating existing practices from the SNS Listserv, this article itemizes the contents of the POD go-kit and its subkits and provides a rationale for its packaging. The Division of Strategic National Stockpile (DSNS) has not certified the proposed "POD go-kit" as a standardized POD go-kit.

  13. Evaluation of textile substrates for dispensing synthetic attractants for malaria mosquitoes.

    PubMed

    Mweresa, Collins K; Mukabana, Wolfgang R; Omusula, Philemon; Otieno, Bruno; Gheysens, Tom; Takken, Willem; van Loon, Joop J A

    2014-08-16

    The full-scale impact of odour-baited technology on the surveillance, sampling and control of vectors of infectious diseases is partly limited by the lack of methods for the efficient and sustainable dispensing of attractants. In this study we investigated whether locally-available and commonly used textiles are efficient substrates for the release of synthetic odorant blends attracting malaria mosquitoes. The relative efficacy of (a) polyester, (b) cotton, (c) cellulose + polyacrylate, and (d) nylon textiles as substrates for dispensing a synthetic odour blend (Ifakara blend 1(IB1)) that attracts malaria mosquitoes was evaluated in western Kenya. The study was conducted through completely randomized Latin square experimental designs under semi-field and field conditions. Traps charged with IB1-impregnated polyester, cotton and cellulose + polyacrylate materials caught significantly more female Anopheles gambiae sensu stricto (semi-field conditions) and An. gambiae sensu lato (field conditions) mosquitoes than IB1-treated nylon (P = 0.001). The IB1-impregnated cellulose + polyacrylate material was the most attractive to female An. funestus mosquitoes compared to all other dispensing textile substrates (P < 0.001). The responses of female An. funestus mosquitoes to IB1-treated cotton and polyester were equal (P = 0.45). Significantly more female Culex mosquitoes were attracted to IB1-treated cotton than to the other treatments (P < 0.001). Whereas IB1-impregnated cotton and cellulose + polyacrylate material attracted equal numbers of female Mansonia mosquitoes (P = 0.44), the catches due to these two substrates were significantly higher than those associated with the other substrates (P < 0.001). The number and species of mosquitoes attracted to a synthetic odour blend is influenced by the type of odour-dispensing material used. Thus, surveillance and intervention programmes for malaria and other mosquito vectors using

  14. GPs' prescription routines and cooperation with other healthcare personnel before and after implementation of multidose drug dispensing.

    PubMed

    Wekre, Liv Johanne; Bakken, Kjersti; Garåsen, Helge; Grimsmo, Anders

    2012-08-01

    This study addresses GPs' attitudes towards multidose drug dispensing before and after implementation and their perceived experience of how multidose drug dispensing affects prescription and communication routines for patients in the home care services. This study contributes to a method triangulation with two other studies on the introduction of multidose drug dispensing in Trondheim. A controlled before-and-after study carried out in Trondheim (intervention) and Tromsø (control). A questionnaire was distributed to all GPs in the two towns in 2005 with a follow-up questionnaire in 2008. The GPs in Trondheim showed a positive attitude to multidose drug dispensing both before and after the implementation. Increased workload was reported, but still the GPs wanted the system to be continued. Most of the GPs reported a better overview of the patients' medication and a supposed reduction in medication errors. The GPs' prescription- and communication routines were changed only for the multidose drug users and not for the other patients in the home care services. The study supports the results presented in two previous publications according to GPs' positive attitude towards multidose drug dispensing, their better overview of the patients' medications, and improved cooperation with the pharmacy. This study adds to our understanding of prescription routines among GPs and the use of the medication module in the electronic health record.

  15. Impact of an automated dispensing system in outpatient pharmacies.

    PubMed

    Humphries, Tammy L; Delate, Thomas; Helling, Dennis K; Richardson, Bruce

    2008-01-01

    To evaluate the impact of an automated dispensing system (ADS) on pharmacy staff work activities and job satisfaction. Cross-sectional, retrospective study. Kaiser Permanente Colorado (KPCO) outpatient pharmacies in September 2005. Pharmacists and technicians from 18 outpatient pharmacies. All KPCO outpatient pharmacists (n = 136) and technicians (n = 160) were surveyed regarding demographics and work activities and pharmacist job satisfaction. Work activities and job satisfaction were compared between pharmacies with and without ADS. Historical prescription purchase records from ADS pharmacies were assessed for pre-ADS to post-ADS changes in productivity. Self-reported pharmacy staff work activities and pharmacist job satisfaction. Pharmacists who responded to the demographic questionnaire (n = 74) were primarily women (60%), had a bachelor's degree in pharmacy (68%), and had been in practice for 10 years or more (53%). Responding technicians (n = 72) were predominantly women (80%) with no postsecondary degree (90%) and fewer than 10 years (68%) in practice. Pharmacists in ADS pharmacies who responded to the work activities questionnaire (n = 50) reported equivalent mean hours spent in patient care activities and filling medication orders compared with non-ADS pharmacists (n = 33; P > 0.05). Similarly, technicians in ADS pharmacies who responded to the work activities questionnaire (n = 64) reported equivalent mean hours spent in filling medication orders compared with non-ADS technicians (n = 38; P > 0.05). An equivalent proportion of ADS pharmacists reported satisfaction with their current job compared with non-ADS pharmacies (P > 0.05). Mean productivity did not increase appreciably after automation (P >0.05). By itself, installing an ADS does not appear to shift pharmacist work activities from dispensing to patient counseling or to increase job satisfaction. Shifting pharmacist work activities from dispensing to counseling and monitoring drug therapy outcomes

  16. Hypervitaminosis D associated with a vitamin D dispensing error.

    PubMed

    Jacobsen, Ryan B; Hronek, Brett W; Schmidt, Ginelle A; Schilling, Margo L

    2011-10-01

    To report a case of hypervitaminosis D resulting in hypercalcemia and acute kidney injury in a 70-year-old female who was prescribed a standard dose of vitamin D but given a toxic dose of vitamin D 50,000 IU (1.25 mg) daily resulting from a dispensing error. A 70-year-old female in her usual state of health was instructed to begin supplementation with vitamin D 1000 IU daily. Three months later she developed confusion, slurred speech, unstable gait, and increased fatigue. She was hospitalized for hypercalcemia and acute kidney injury secondary to hypervitaminosis D. All vitamin D supplementation was discontinued and 5 months after discharge, the patient's serum calcium and vitamin D concentrations, as well as renal function, had returned to baseline values. Upon review of the patient's records, it was discovered that she had been taking vitamin D 50,000 IU daily. There is an increased interest in vitamin D, resulting in more health care providers recommending--and patients taking--supplemental vitamin D. Hypervitaminosis D is rarely reported and generally only in the setting of gross excess of vitamin D. This report highlights a case of hypervitaminosis D in the setting of a prescribed standard dose of vitamin D that resulted in toxic ingestion of vitamin D 50,000 IU daily due to a dispensing error. As more and more people use vitamin D supplements, it is important to recognize that, while rare, hypervitaminosis D is a possibility and dosage conversion of vitamin D units can result in errors. Health care providers and patients should be educated on the advantages and risks associated with vitamin D supplementation and be informed of safety measures to avoid hypervitaminosis D. In addition, health care providers should understand dosage conversion regarding vitamin D and electronic prescribing and dispensing software should be designed to detect such errors.

  17. Suppression of mediterranean fruit fly(Diptera: Tephritidae) with trimedlure(TML) dispensers and biolure in coffee(Coffea arabica L)

    USDA-ARS?s Scientific Manuscript database

    Solid Trimedlure[TML] dispensers and novel solid triple lure dispensers[TMR] without insecticides were tested as “attract and kill” devices alone and in combination with Biolure mass trapping to evaluate suppression of Mediterranean fruit fly, Ceratitis capitata(Wiedemann) in a large coffee plantati...

  18. 40 CFR Table 1 to Subpart Cccccc... - Applicability Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000 Gallons of Gasoline or More1... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline... Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000...

  19. 40 CFR Table 1 to Subpart Cccccc... - Applicability Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000 Gallons of Gasoline or More1... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline... Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000...

  20. 40 CFR Table 1 to Subpart Cccccc... - Applicability Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000 Gallons of Gasoline or More1... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline... Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000...

  1. 40 CFR Table 1 to Subpart Cccccc... - Applicability Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000 Gallons of Gasoline or More1... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline... Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000...

  2. 40 CFR 86.146-96 - Fuel dispensing spitback procedure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... or methanol. The bag shall be designed and used so that liquid fuel does not spit back onto the... the orifice of the filler pipe. The bag must be designed to permit passage of the dispensing nozzle through the bag. If the bag has been used for previous testing, sufficient time shall be allowed for the...

  3. 40 CFR 86.146-96 - Fuel dispensing spitback procedure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... or methanol. The bag shall be designed and used so that liquid fuel does not spit back onto the... the orifice of the filler pipe. The bag must be designed to permit passage of the dispensing nozzle through the bag. If the bag has been used for previous testing, sufficient time shall be allowed for the...

  4. 40 CFR 86.1246-96 - Fuel dispensing spitback procedure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... or methanol. The bag shall be designed and used so that liquid fuel does not spit back onto the... the orifice of the filler pipe. The bag must be designed to permit passage of the dispensing nozzle through the bag. If the bag has been used for previous testing, sufficient time shall be allowed for the...

  5. 40 CFR 86.1246-96 - Fuel dispensing spitback procedure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... or methanol. The bag shall be designed and used so that liquid fuel does not spit back onto the... the orifice of the filler pipe. The bag must be designed to permit passage of the dispensing nozzle through the bag. If the bag has been used for previous testing, sufficient time shall be allowed for the...

  6. 40 CFR 86.146-96 - Fuel dispensing spitback procedure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... or methanol. The bag shall be designed and used so that liquid fuel does not spit back onto the... the orifice of the filler pipe. The bag must be designed to permit passage of the dispensing nozzle through the bag. If the bag has been used for previous testing, sufficient time shall be allowed for the...

  7. 21 CFR 1306.07 - Administering or dispensing of narcotic drugs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 9 2013-04-01 2013-04-01 false Administering or dispensing of narcotic drugs. 1306.07 Section 1306.07 Food and Drugs DRUG ENFORCEMENT ADMINISTRATION, DEPARTMENT OF JUSTICE... an incidental adjunct to medical or surgical treatment of conditions other than addiction, or to...

  8. 21 CFR 1306.07 - Administering or dispensing of narcotic drugs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 9 2014-04-01 2014-04-01 false Administering or dispensing of narcotic drugs. 1306.07 Section 1306.07 Food and Drugs DRUG ENFORCEMENT ADMINISTRATION, DEPARTMENT OF JUSTICE... an incidental adjunct to medical or surgical treatment of conditions other than addiction, or to...

  9. 21 CFR 1306.07 - Administering or dispensing of narcotic drugs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 9 2012-04-01 2012-04-01 false Administering or dispensing of narcotic drugs. 1306.07 Section 1306.07 Food and Drugs DRUG ENFORCEMENT ADMINISTRATION, DEPARTMENT OF JUSTICE... an incidental adjunct to medical or surgical treatment of conditions other than addiction, or to...

  10. Potential drug-drug interactions between anti-cancer agents and community pharmacy dispensed drugs.

    PubMed

    Voll, Marsha L; Yap, Kim D; Terpstra, Wim E; Crul, Mirjam

    2010-10-01

    To identify the prevalence of potential drug-drug interactions between hospital pharmacy dispensed anti-cancer agents and community pharmacy dispensed drugs. A retrospective cohort study was conducted on the haematology/oncology department of the internal medicine ward in a large teaching hospital in Amsterdam, the Netherlands. Prescription data from the last 100 patients treated with anti-cancer agents were obtained from Paracelsus, the chemotherapy prescribing system in the hospital. The community pharmacy dispensed drugs of these patients were obtained by using OZIS, a system that allows regionally linked pharmacies to call up active medication on any patient. Both medication lists were manually screened for potential drug-drug interactions by using several information sources on interactions, e.g. Pubmed, the Flockhart P450 table, Micromedex and Dutch reference books. Prevalence of potential drug-drug interactions between anti-cancer agents provided by the hospital pharmacy and drugs dispensed by the community pharmacy. Ninety-one patients were included in the study. A total of 31 potential drug-drug interactions were found in 16 patients, of which 15 interactions were clinically relevant and would have required an intervention. Of these interactions 1 had a level of severity ≥ D, meaning the potential drug-drug interaction could lead to long lasting or permanent damage, or even death. The majority of the interactions requiring an intervention (67%) had a considerable level of evidence (≥ 2) and were based on well-documented case reports or controlled interaction studies. Most of the potential drug-drug interactions involved the antiretroviral drugs (40%), proton pump inhibitors (20%) and antibiotics (20%). The anti-cancer drug most involved in the drug-drug interactions is methotrexate (33%). This study reveals a high prevalence of potential drug-drug interactions between anti-cancer agents provided by the hospital pharmacy and drugs dispensed by the

  11. ASHP national survey of pharmacy practice in hospital settings: dispensing and administration--2011.

    PubMed

    Pedersen, Craig A; Schneider, Philip J; Scheckelhoff, Douglas J

    2012-05-01

    Results of the 2011 ASHP national survey of pharmacy practice in hospital settings that pertain to dispensing and administration are presented. A stratified random sample of pharmacy directors at 1401 general and children's medical-surgical hospitals in the United States were surveyed by mail. In this national probability sample survey, the response rate was 40.1%. Decentralization of the medication-use system continues, with 40% of hospitals using a decentralized system and 58% of hospitals planning to use a decentralized model in the future. Automated dispensing cabinets were used by 89% of hospitals, robots were used by 11%, carousels were used in 18%, and machine-readable coding was used in 34% of hospitals to verify doses before dispensing. Overall, 65% of hospitals had a United States Pharmacopeia chapter 797 compliant cleanroom for compounding sterile preparations. Medication administration records (MARs) have become increasingly computerized, with 67% of hospitals using electronic MARs. Bar-code-assisted medication administration was used in 50% of hospitals, and 68% of hospitals had smart infusion pumps. Health information is becoming more electronic, with 67% of hospitals having partially or completely implemented an electronic health record and 34% of hospitals having computerized prescriber order entry. The use of these technologies has substantially increased over the past year. The average number of full-time equivalent staff per 100 occupied beds averaged 17.5 for pharmacists and 15.0 for technicians. Directors of pharmacy reported declining vacancy rates for pharmacists. Pharmacists continue to improve medication use at the dispensing and administration steps of the medication-use system. The adoption of new technology is changing the philosophy of medication distribution, and health information is rapidly becoming electronic.

  12. Understanding the Role of Accredited Drug Dispensing Outlets in Tanzania's Health System.

    PubMed

    Embrey, Martha; Vialle-Valentin, Catherine; Dillip, Angel; Kihiyo, Bernard; Mbwasi, Romuald; Semali, Innocent A; Chalker, John C; Liana, Jafary; Lieber, Rachel; Johnson, Keith; Rutta, Edmund; Kimatta, Suleiman; Shekalaghe, Elizabeth; Valimba, Richard; Ross-Degnan, Dennis

    2016-01-01

    People in many low-income countries access medicines from retail drug shops. In Tanzania, a public-private partnership launched in 2003 used an accreditation approach to improve access to quality medicines and pharmaceutical services in underserved areas. The government scaled up the accredited drug dispensing outlet (ADDO) program nationally, with over 9,000 shops now accredited. This study assessed the relationships between community members and their sources of health care and medicines, particularly antimicrobials, with a specific focus on the role ADDOs play in the health care system. Using mixed methods, we collected data in four regions. We surveyed 1,185 households and audited 96 ADDOs and 84 public/nongovernmental health facilities using a list of 17 tracer drugs. To determine practices in health facilities, we interviewed 1,365 exiting patients. To assess dispensing practices, mystery shoppers visited 306 ADDOs presenting one of three scenarios (102 each) about a child's respiratory symptoms. Of 614 household members with a recent acute illness, 73% sought outside care-30% at a public facility and 31% at an ADDO. However, people bought medicines more often at ADDOs no matter who recommended the treatment; of the 581 medicines that people had received, 49% came from an ADDO. Although health facilities and ADDOs had similar availability of antimicrobials, ADDOs had more pediatric formulations available (p<0.001). The common perception was that drugs from ADDOs are more expensive, but the difference in the median cost to treat pneumonia was relatively minimal (US$0.26 in a public facility and US$0.30 in an ADDO). Over 20% of households said they had someone with a chronic condition, with 93% taking medication, but ADDOs are allowed to sell very few chronic care-related medicines. ADDO dispensers are trained to refer complicated cases to a health facility, and notably, 99% of mystery shoppers presenting a pneumonia scenario received an antimicrobial (54%), a

  13. Improving access to medicines through centralised dispensing in the public sector: a case study of the Chronic Dispensing Unit in the Western Cape Province, South Africa.

    PubMed

    Magadzire, Bvudzai Priscilla; Marchal, Bruno; Ward, Kim

    2015-11-17

    The Chronic Dispensing Unit (CDU) is an out-sourced, public sector centralised dispensing service that has been operational in the Western Cape Province in South Africa since 2005. The CDU dispenses medicines for stable patients with chronic conditions. The aim is to reduce pharmacists' workload, reduce patient waiting times and decongest healthcare facilities. Our objectives are to describe the intervention's scope, illustrate its interface with the health system and describe its processes and outcomes. Secondly, to quantify the magnitude of missed appointments by enrolled patients and to describe the implications thereof in order to inform a subsequent in-depth empirical study on the underlying causes. We adopted a case study design in order to elicit the programme theory underlying the CDU strategy. We consulted 15 senior and middle managers from the provincial Department of Health who were working closely with the intervention and the contractor using focus group discussions and key informant interviews. In addition, relevant literature, and policy and programme documents were reviewed and analysed. We found that the CDU scope has significantly expanded over the last 10 years owing to technological advancements. As such, in early 2015, the CDU produced nearly 300,000 parcels monthly. Medicines supply, patient enrollment processes, healthcare professionals' compliance to legislation and policies, mechanisms for medicines distribution, management of non-collected medicines (emanating from patients' missed appointments) and the array of actors involved are all central to the CDU's functioning. Missed appointments by patients are a problem, affecting an estimated 8%-12% of patients each month. However, the causes have not been investigated thoroughly. Implications of missed appointments include a cost to government for services rendered by the contractor, potential losses due to expired medicines, additional workload for the contractor and healthcare facility staff

  14. Hand sanitiser provision for reducing illness absences in primary school children: a cluster randomised trial.

    PubMed

    Priest, Patricia; McKenzie, Joanne E; Audas, Rick; Poore, Marion; Brunton, Cheryl; Reeves, Lesley

    2014-08-01

    The potential for transmission of infectious diseases offered by the school environment are likely to be an important contributor to the rates of infectious disease experienced by children. This study aimed to test whether the addition of hand sanitiser in primary school classrooms compared with usual hand hygiene would reduce illness absences in primary school children in New Zealand. This parallel-group cluster randomised trial took place in 68 primary schools, where schools were allocated using restricted randomisation (1:1 ratio) to the intervention or control group. All children (aged 5 to 11 y) in attendance at participating schools received an in-class hand hygiene education session. Schools in the intervention group were provided with alcohol-based hand sanitiser dispensers in classrooms for the winter school terms (27 April to 25 September 2009). Control schools received only the hand hygiene education session. The primary outcome was the number of absence episodes due to any illness among 2,443 follow-up children whose caregivers were telephoned after each absence from school. Secondary outcomes measured among follow-up children were the number of absence episodes due to specific illness (respiratory or gastrointestinal), length of illness and illness absence episodes, and number of episodes where at least one other member of the household became ill subsequently (child or adult). We also examined whether provision of sanitiser was associated with experience of a skin reaction. The number of absences for any reason and the length of the absence episode were measured in all primary school children enrolled at the schools. Children, school administrative staff, and the school liaison research assistants were not blind to group allocation. Outcome assessors of follow-up children were blind to group allocation. Of the 1,301 and 1,142 follow-up children in the hand sanitiser and control groups, respectively, the rate of absence episodes due to illness per 100

  15. 21 CFR 866.2440 - Automated medium dispensing and stacking device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated medium dispensing and stacking device. 866.2440 Section 866.2440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2440...

  16. 21 CFR 866.2440 - Automated medium dispensing and stacking device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated medium dispensing and stacking device. 866.2440 Section 866.2440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2440...

  17. 21 CFR 866.2440 - Automated medium dispensing and stacking device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated medium dispensing and stacking device. 866.2440 Section 866.2440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2440...

  18. 21 CFR 866.2440 - Automated medium dispensing and stacking device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated medium dispensing and stacking device. 866.2440 Section 866.2440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2440...

  19. 21 CFR 866.2440 - Automated medium dispensing and stacking device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated medium dispensing and stacking device. 866.2440 Section 866.2440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2440...

  20. Using the six sigma process to implement the Centers for Disease Control and Prevention Guideline for Hand Hygiene in 4 intensive care units.

    PubMed

    Eldridge, Noel E; Woods, Susan S; Bonello, Robert S; Clutter, Kay; Ellingson, Leann; Harris, Mary Ann; Livingston, Barbara K; Bagian, James P; Danko, Linda H; Dunn, Edward J; Parlier, Renee L; Pederson, Cheryl; Reichling, Kim J; Roselle, Gary A; Wright, Steven M

    2006-02-01

    The Centers for Disease Control and Prevention (CDC) Guideline for Hand Hygiene in Health Care Settings was issued in 2002. In 2003, the Joint Commission on Accreditation of Healthcare Organizations (JCAHO) established complying with the CDC Guideline as a National Patient Safety Goal for 2004. This goal has been maintained through 2006. The CDC's emphasis on the use of alcohol-based hand rubs (ABHRs) rather than soap and water was an opportunity to improve compliance, but the Guideline contained over 40 specific recommendations to implement. To use the Six Sigma process to examine hand hygiene practices and increase compliance with the CDC hand hygiene recommendations required by JCAHO. Six Sigma Project with pre-post design. Physicians, nurses, and other staff working in 4 intensive care units at 3 hospitals. Observed compliance with 10 required hand hygiene practices, mass of ABHR used per month per 100 patient-days, and staff attitudes and perceptions regarding hand hygiene reported by questionnaire. Observed compliance increased from 47% to 80%, based on over 4,000 total observations. The mass of ABHR used per 100 patient-days in 3 intensive care units (ICUs) increased by 97%, 94%, and 70%; increases were sustained for 9 months. Self-reported compliance using the questionnaire did not change. Staff reported increased use of ABHR and increased satisfaction with hand hygiene practices and products. The Six Sigma process was effective for organizing the knowledge, opinions, and actions of a group of professionals to implement the CDC's evidence-based hand hygiene practices in 4 ICUs. Several tools were developed for widespread use.