Sample records for hand rub products

  1. Revisiting the hand wipe versus gel rub debate: is a higher-ethanol content hand wipe more effective than an ethanol gel rub?

    PubMed

    D'Antonio, Natalie N; Rihs, John D; Stout, Janet E; Yu, Victor L

    2010-11-01

    The Centers for Disease Control and Prevention's guidelines for hand hygiene state that the use of alcohol-based hand wipes is not an effective substitute for the use of an alcohol-based hand rub or handwashing with an antimicrobial soap and water. The objective of this study was to determine whether a hand wipe with higher ethanol content (65.9%) is as effective as an ethanol hand rub or antimicrobial soap in removing bacteria and spores from hands. In two separate experiments, the hands of 7 subjects were inoculated with a suspension of Serratia marcescens or Geobacillus stearothermophilus. Subjects washed with each of 3 different products: 65.9% ethanol hand wipes (Sani-Hands ALC), 62% ethanol gel rub (Purell), and antimicrobial soap containing 0.75% triclosan (Kindest Kare). A total of 56 observations were analyzed for S marcescens removal and 70 observations were analyzed for G stearothermophilus removal. The rank order of product efficacy for both bacteria and spore removal was antibacterial soap > 65.9% ethanol hand wipes >62% ethanol hand rub. Mean S marcescens log reductions (±SD) for the 65.9% ethanol alcohol wipe, 62% ethanol alcohol rub, and antimicrobial foam soap were 3.44 ± 0.847, 2.32 ± 1.065, and 4.44 ± 1.018, respectively (P < .001). Mean G stearothermophilus log reductions for the 65.9% ethanol wipe, 62% ethanol rub, and antimicrobial foam soap were 0.51 ± 0.26, -0.8 ± 0.32 increase over baseline, and 1.72 ± 0.62, respectively (P < .001). The alcohol-based hand wipe containing 65.9% ethanol was significantly more effective than the 62% ethanol rub in reducing the number of viable bacteria and spores on the hands. Copyright © 2010 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  2. Recommendations and requirements for soap and hand rub dispensers in healthcare facilities.

    PubMed

    Assadian, Ojan; Kramer, Axel; Christiansen, Bärbel; Exner, Martin; Martiny, Heike; Sorger, Arno; Suchomel, Miranda

    2012-01-01

    Hand hygiene is one of the most important measures to prevent transmission of infectious agents and plays a major role in prevention of infection in any type of healthcare setting. While requirements for the efficacy of hand disinfectants are defined in European testing norms such as the EN 1500 for hygienic hand disinfection or EN 12791 for surgical hand preparation, no specific recommendations for hand rub dispensers and liquid soap dispensers have been given yet. Therefore, the intention of the present recommendation on soap and hand rub dispensers in healthcare facilities is to close this gap and to enhance future improvement of dispenser functionality and design. Regardless of manufacture and design of a hand rub or liquid soap dispensers the following requirements shall be met in healthcare facilities:Triggering the dispenser must be possible without using hands. Sensor- or elbow-operated dispensers both fulfill this requirement. Dispensers must be only refillable in a modality where the content, be it a hand rub or liquid soap, cannot be contaminated. This is achieved best by using replaceable cartridge systems. Refilling through "top-up" must not be possible. The disperser should allow usage of different types of cartridges made by different manufacturers. Dispensers must be operated and maintained such that a microbial contamination of the pump nozzle may easily be avoided. It must be possible to identify the products used in a dispenser easily and without any manipulation. Identifying the type of product, be it a hand rub or a liquid soap, as well as reading the product's name and critical manufacturers' warnings must be possible at any time. The disperser must allow identification of the level of the used product without any further manipulation at any time. The design of the dispenser must allow easy cleaning and disinfection the outside and inside of the dispenser. The manufacturer of the dispenser must provide the user with information on applicable

  3. Hand hygiene with alcohol hand rub and gloves reduces the incidence of late onset sepsis in preterm neonates.

    PubMed

    Janota, Jan; Šebková, Sylva; Višňovská, Magda; Kudláčková, Jana; Hamplová, Drahomíra; Zach, Jiří

    2014-10-01

    To assess the impact of a hand hygiene protocol, using hand washing, alcohol hand rub and gloves when caring for preterm infants born after 31 weeks of gestation, on the incidence of neonatal late onset sepsis (LOS). All babies delivered between 32 + 0 and 36 + 6 weeks gestation and admitted to the neonatal intensive care unit during a 14-month period were included. We followed a hand hygiene protocol with hand washing and alcohol hand rub (hand rub period) for the first 7 months and a protocol of hand washing, alcohol hand rub and gloves (gloves period) for the second 7 months. The hand rub and gloves groups consisted of 111 and 89 patients, respectively. Five patients were diagnosed with a total of six episodes of LOS in the hand rub group, and the incidence of LOS during the hand rub period was 2.99/1000 hospital days and 54.1/1000 admissions. There were no patients diagnosed with LOS during the gloves period (significant decrease, p = 0.028). Using a hand hygiene protocol with hand washing, hand rub and gloves significantly reduced the incidence of LOS in preterm newborns, and the results suggest that it may produce a sustained improvement in the infection rate. ©2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  4. Waterless Hand Rub Versus Traditional Hand Scrub Methods for Preventing the Surgical Site Infection in Orthopedic Surgery.

    PubMed

    Iwakiri, Kentaro; Kobayashi, Akio; Seki, Masahiko; Ando, Yoshiyuki; Tsujio, Tadao; Hoshino, Masatoshi; Nakamura, Hiroaki

    2017-11-15

    MINI: Fourteen hundred consecutive patients were investigated for evaluating the utility of waterless hand rub before orthopaedic surgery. The risk in the surgical site infection incidence was the same, but costs of liquids used for hand hygiene were cheaper and the hand hygiene time was shorter for waterless protocol, compared with traditional hand scrub. A retrospective cohort study with prospectively collected data. The aim of this study was to compare SSI incidences, the cost of hand hygiene agents, and hand hygiene time between the traditional hand scrub and the waterless hand rub protocols before orthopedic surgery. Surgical site infections (SSI) prolong hospitalization and are a leading nosocomial cause of morbidity and a source of excess cost. Recently, a waterless hand rub protocol comprising alcohol based chlorhexidine gluconate for use before surgery was developed, but no studies have yet examined its utility in orthopedic surgery. Fourteen hundred consecutive patients who underwent orthopedic surgery (spine, joint replacement, hand, and trauma surgeries) in our hospital since April 1, 2012 were included. A total of 712 cases underwent following traditional hand scrub between April 1, 2012 and April 30, 2013 and 688 cases underwent following waterless hand rub between June 1, 2013 and April 30, 2014. We compared SSI incidences within all and each subcategory between two hand hygiene protocols. All patients were screened for SSI within 1 year after surgery. We compared the cost of hand hygiene agents and hand hygiene time between two groups. The SSI incidences were 1.3% (9 of 712) following the traditional protocol (2 deep and 7 superficial infections) and 1.1% (8 of 688) following the waterless protocol (all superficial infections). There were no significant differences between the two groups. The costs of liquids used for one hand hygiene were about $2 for traditional hand scrub and less than $1 for waterless hand rub. The mean hand hygiene time was 264

  5. Single treatment with ethanol hand rub is ineffective against human rhinovirus--hand washing with soap and water removes the virus efficiently.

    PubMed

    Savolainen-Kopra, Carita; Korpela, Terttu; Simonen-Tikka, Marja-Leena; Amiryousefi, Ali; Ziegler, Thedi; Roivainen, Merja; Hovi, Tapani

    2012-03-01

    Ethanol-containing hand rubs are used frequently as a substitute for hand washing with water and soap. However, not all viruses are inactivated by a short term rubbing with alcohol. The capacity of a single round of instructed and controlled hand cleaning with water and soap or ethanol-containing hand rub, respectively, was tested for removal of human rhinovirus administered onto the skin of healthy volunteers on the back of the hands. Hand washing with soap and water appeared to be much more efficient for removing rhinoviruses from skin than rubbing hands with an ethanol-containing disinfectant. After washing with soap and water the virus was detected in 3/9 (33.3%) test persons from the left hand and 1/9 (11.1%) cases from the right hand, whereas the virus was detected invariably by real-time RT-PCR from both hands after cleaning with alcohol hand rub (P-value <0.01). Both substances evaluated clinically were also tested in vitro for virucidal efficacy against Human rhinovirus2 (HRV2) using a standardized assay. Both tested substances were poor within the contact time used in the hand-cleaning test. In conclusion, thorough and conventional hand washing with water and soap can clean efficiently hands contaminated with the virus responsible for an extensive share of common cold episodes. Copyright © 2012 Wiley Periodicals, Inc.

  6. A Kinetic Study Using Evaporation of Different Types of Hand-Rub Sanitizers

    ERIC Educational Resources Information Center

    Pinhas, Allan R.

    2010-01-01

    Alcohol-based hand-rub sanitizers are the types of products that hospital professionals use very often. These sanitizers can be classified into two major groups: those that contain a large quantity of thickener, and thus are a gel, and those that contain a small quantity of thickener, and thus remain a liquid. In an effort to create a laboratory…

  7. Epidemiologic Background of Hand Hygiene and Evaluation of the Most Important Agents for Scrubs and Rubs

    PubMed Central

    Kampf, Günter; Kramer, Axel

    2004-01-01

    The etiology of nosocomial infections, the frequency of contaminated hands with the different nosocomial pathogens, and the role of health care workers' hands during outbreaks suggest that a hand hygiene preparation should at least have activity against bacteria, yeasts, and coated viruses. The importance of efficacy in choosing the right hand hygiene product is reflected in the new Centers for Disease Control and Prevention guideline on hand hygiene (J. M. Boyce and D. Pittet, Morb. Mortal. Wkly. Rep. 51:1-45, 2002). The best antimicrobial efficacy can be achieved with ethanol (60 to 85%), isopropanol (60 to 80%), and n-propanol (60 to 80%). The activity is broad and immediate. Ethanol at high concentrations (e.g., 95%) is the most effective treatment against naked viruses, whereas n-propanol seems to be more effective against the resident bacterial flora. The combination of alcohols may have a synergistic effect. The antimicrobial efficacy of chlorhexidine (2 to 4%) and triclosan (1 to 2%) is both lower and slower. Additionally, both agents have a risk of bacterial resistance, which is higher for chlorhexidine than triclosan. Their activity is often supported by the mechanical removal of pathogens during hand washing. Taking the antimicrobial efficacy and the mechanical removal together, they are still less effective than the alcohols. Plain soap and water has the lowest efficacy of all. In the new Centers for Disease Control and Prevention guideline, promotion of alcohol-based hand rubs containing various emollients instead of irritating soaps and detergents is one strategy to reduce skin damage, dryness, and irritation. Irritant contact dermatitis is highest with preparations containing 4% chlorhexidine gluconate, less frequent with nonantimicrobial soaps and preparations containing lower concentrations of chlorhexidine gluconate, and lowest with well-formulated alcohol-based hand rubs containing emollients and other skin conditioners. Too few published data

  8. Surgical hand antisepsis in veterinary practice: evaluation of soap scrubs and alcohol based rub techniques.

    PubMed

    Verwilghen, Denis R; Mainil, Jacques; Mastrocicco, Emilie; Hamaide, Annick; Detilleux, Johann; van Galen, Gaby; Serteyn, Didier; Grulke, Sigrid

    2011-12-01

    Recent studies have shown that hydro-alcoholic solutions are more efficient than traditional medicated soaps in the pre-surgical hand antisepsis of human surgeons but there is little veterinary literature on the subject. The aim of this study was to compare the efficiency of medicated soaps and a hydro-alcoholic solution prior to surgery using an in-use testing method in a veterinary setting. A preliminary trial was performed that compared the mean log(10) number of bacterial colony forming units (CFU) and the reduction factors (RF) between two 5-min hand-scrubbing sessions using different soaps, namely, povidone iodine (PVP) and chlorhexidine gluconate (CHX), and the 1.5-min application of a hydro-alcoholic rub. A clinical in-use trial was then used to compare the hydro-alcoholic rub and CHX in a surgical setting. Sampling was performed using finger printing on agar plates. The hydro-alcoholic rub and CHX had a similar immediate effect, although the sustained effect was significantly better for the hydro-alcoholic rub, while PVP had a significantly lower immediate and sustained effect. The hydro-alcoholic rub showed good efficiency in the clinical trial and could be considered as a useful alternative method for veterinary surgical hand antisepsis. Copyright © 2010 Elsevier Ltd. All rights reserved.

  9. Preoperative Hand Decontamination in Ophthalmic Surgery: A Comparison of the Removal of Bacteria from Surgeons' Hands by Routine Antimicrobial Scrub versus an Alcoholic Hand Rub.

    PubMed

    Forer, Yaara; Block, Colin; Frenkel, Shahar

    2017-09-01

    The goal of this experiment was to evaluate and compare the antimicrobial efficacy of routine preoperative hand washing using commercial medicated sponge brushes versus an alcoholic hand rub, by comparing bacterial growth on ophthalmic surgeons' hands after application of each of these methods. Twenty ophthalmic surgeons were recruited at the Hadassah-Hebrew University Medical Center in Jerusalem, Israel. Samples were collected twice from the hands of each surgeon after hand decontamination using two different protocols during routine surgical practice. The routine preparation consisted of a 3-minute surgical scrub using commercial brush-sponges incorporating either 4% chlorhexidine gluconate (CHG) or 1% povidone-iodine (PVP-I) formulations with detergent, followed by drying the hands with a sterile towel, while the 70% ethanol solution was applied for 60-seconds and allowed to air dry. Half of the group was randomly assigned to provide samples first after the routine method and the alcoholic solution a week later, and the other half of the group was sampled in the reverse order. Viable counts of bacteria were evaluated using a modified glove juice method. Bacterial colonies were enumerated after incubation for 24 hours and expressed as colony forming units (CFU)/mL for each pair of hands. Geometric mean counts were 1310 and 39 CFU/mL, in the routine and alcohol rub groups, respectively, representing a mean log 10 reduction in 1.53. The difference between the paired bacterial counts for the routine versus the alcohol rub was statistically significant (p < 0.0001). There was no statistically significant difference between log 10 reductions for CHG and PVP-I (p = 0.97). This study provides evidence that an alcohol rub protocol is more effective in reducing bacterial counts on hands than routine surgical hand preparation with PVP-I and CHG in a population of practicing ophthalmic surgeons in the operative clinical setting. Thus, it provides a safe alternative as a

  10. [Development of alternative to animal experiment in evaluation of skin irritation caused by alcohol-based hand rubs].

    PubMed

    Yamamoto, Nobuyuki; Miyamoto, Koji; Katoh, Masakazu

    2010-08-01

    Alcohol-based hand rubs are widely used for infection control in clinical practice. However, it is known that frequent use of the alcohol-based hand rubs may cause skin irritation. To predict the skin irritation in human, animal experiments are quite useful. Especially, the Draize Test using rabbits is suitable for this purpose because their skin is highly sensitive. On the other hand, the development of alternative to animal experiments is important not only from the viewpoint of ethical aspects but also from the efficient research and development. Reconstructed human epidermis (RhE) was developed as a human skin equivalent model in vitro, and has been applied to the evaluation of skin irritation. But the RhE has not been utilized for the evaluation of alcohol-based hand rubs because of the high skin permeability and cytotoxicity of alcohols. The aim of this study was to develop a new method using the RhE in evaluation of skin irritation caused by alcohol-based hand rubs. The authors propose an experimental technique named "Skin model blowing method (SMBM)" consisting of the sequential procedure as follows; applying small amount of testing sample on RhE, blow-dry, post incubation, and cell viability measurement. According to the SMBM, the skin irritation caused by alcohol-based hand rubs could be evaluated under the similar condition of their actual use. It was found that a high correlation existed between the cell viability obtained from SMBM and the skin irritation index in rabbit which had been reported previously.

  11. Surgical hand disinfection with a propanol-based hand rub: equivalence of shorter application times.

    PubMed

    Kampf, G; Ostermeyer, C; Heeg, P

    2005-04-01

    The aim of this study was to determine the efficacy of a propanol-based hand rub at application times shorter than 3 min. The bacterial pre-value was obtained from the finger tips (prEN 12791). Subjects treated their hands with the reference procedure (n-propanol, 60%) for 3 min or the product (crossover design). Sterillium was applied for 3, 2, 1.5 and 1 min. Four other preparations were tested for 1 min. Post-values (immediate effect) were taken from one hand, and the other hand was gloved for 3h. After the gloves were removed, the second post-value was taken (sustained effect). Sterillium was more effective than the reference procedure at 3, 2 and 1.5 min (immediate and sustained effect). The immediate effect after 1 min was significantly lower [mean log(10) reduction factor (RF): 1.91+/-0.90 vs. 2.52+/-0.95; P=0.001], whereas the sustained effect was not (mean RF: 1.81+/-1.06 vs. 2.05+/-1.14; P=0.204). All other preparations failed the efficacy requirement at 1 min for both the immediate and sustained effect. Using 2 x 3 mL Sterillium for a total of 1.5 min for surgical hand disinfection was at least as effective as the 3-min reference disinfection.

  12. Survey of attitudes and practices of Irish nursing students towards hand hygiene, including handrubbing with alcohol-based hand rub.

    PubMed

    Kingston, Liz M; O'Connell, Nuala H; Dunne, Colum P

    2017-05-01

    Hand hygiene is widely recognised as the most important measure a healthcare worker can take in preventing the spread of healthcare associated infections. As a member of the healthcare team, nursing students have direct patient contact during clinical practice; hence, good hand hygiene practice among nursing students is essential. Low to moderate levels of hand hygiene knowledge and poor attitudes and practices are reported among nursing students. However, less is known about their attitudes and practices of handrubbing with ABHR, even though handrubbing is the recommended optimum practice in most situations. The aim of this study was to explore attitudes and practices of hand hygiene, in particular handrubbing with alcohol-based hand rub, among nursing students in Ireland. This survey employed a descriptive, self-report design using a questionnaire to gather data. It was administered electronically to all undergraduate nursing students (n=342) in the Department of Nursing and Midwifery at the University of Limerick, Ireland in March and April 2015. Response rate was 66%. Attitudes towards hand hygiene were generally positive. Compliance with hand hygiene after contact with body fluid was high (99.5%) and before a clean or aseptic procedure (98.5%). However, suboptimal practices emerged, before touching a patient (85%), after touching a patient (87%) and after touching patients' surroundings (61%), with first year students more compliant than fourth year students. 16% of students were not aware of the clinical contraindications for using alcohol-based hand rub and 9% did not know when to use soap and water and when to use alcohol-based hand rub. Educators and practitioners play an important role in ensuring that nursing students develop appropriate attitudes towards hand hygiene and engage in optimal handrubbing practices. Raising awareness among nursing students of their responsibility in preventing the occurrence and reducing the transmission of HCAI as an on

  13. Comparison of 3 in vivo methods for assessment of alcohol-based hand rubs.

    PubMed

    Edmonds-Wilson, Sarah; Campbell, Esther; Fox, Kyle; Macinga, David

    2015-05-01

    Alcohol-based hand rubs (ABHRs) are the primary method of hand hygiene in health-care settings. ICPs increasingly are assessing ABHR product efficacy data as improved products and test methods are developed. As a result, ICPs need better tools and recommendations for how to assess and compare ABHRs. Two ABHRs (70% ethanol) were tested according to 3 in vivo methods approved by ASTM International: E1174, E2755, and E2784. Log10 reductions were measured after a single test product use and after 10 consecutive uses at an application volume of 2 mL. The test method used had a significant influence on ABHR efficacy; however, in this study the test product (gel or foam) did not significantly influence efficacy. In addition, for all test methods, log10 reductions obtained after a single application were not predictive of results after 10 applications. Choice of test method can significantly influence efficacy results. Therefore, when assessing antimicrobial efficacy data of hand hygiene products, ICPs should pay close attention to the test method used, and ensure that product comparisons are made head to head in the same study using the same test methodology. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  14. Sustained antibacterial effect of a hand rub gel incorporating chlorhexdine-loaded nanocapsules (Nanochlorex).

    PubMed

    Nhung, Dang Thi Tuyet; Freydiere, Anne-Marie; Constant, Hélène; Falson, Françoise; Pirot, Fabrice

    2007-04-04

    In the present study, an original chlorhexidine-loaded nanocapsule-based gel (Nanochlorex) was tested as hand rub gel against the resident skin flora in comparison with 2-propanol 60% (v/v) and 62% (v/v) ethanol-based gel (Purell). After 30-s hand rub, the immediate bactericidal effect of Nanochlorex was found comparable to 2-propanol 60% (v/v) (reduction factor, RF: 0.30+/-0.35 versus 0.38+/-0.55, P>0.05) against aerobic bacteria, whereas the post-values of surviving anaerobes were shown significantly lower from Nanochlorex (P<0.001) and insignificant from 2-propanol 60% (v/v) (P>0.05). Sustained antibacterial effect of Nanochlorex was confirmed against the resident and transient hand flora in two sets of experiment. In the first, the results obtained with the glove-juice technique showed that the bactericidal effect induced by Nanochlorex hand rub persisted throughout 3-h period, while Purell failed to reduce significantly the post-values of surviving bacteria. In the second, repeated artificial contaminations with Staphylococcus epidermidis was carried out onto ex vivo human skin pre-treated by either Nanochlorex or Purell for 5min, then maintained in cell diffusion apparatus for 4h. The log(10) reduction of surviving bacteria was significantly higher with Nanochlorex than that determined with Purell after three successive contaminations (from approximately 5.5 to 1.5 log(10) reduction for Nanochlorex between the first and the third contamination; approximately 1log(10) reduction for Purell throughout the experiment), confirming the sustained antibacterial effect of chlorhexidine-loaded nanocapsule-based gel. The immediate and sustained antibacterial effect of Nanochlorex was explained by chlorhexidine carrier system which improved the drug targeting to bacteria and reduced from osmotic gel further bacterial growth on the skin. Nanochlorex) might constitute a promising approach for hygienic hand disinfection in care practice performing multiple procedures.

  15. Quest for a Realistic In Vivo Test Method for Antimicrobial Hand-Rub Agents: Introduction of a Low-Volume Hand Contamination Procedure▿

    PubMed Central

    Macinga, David R.; Beausoleil, Christopher M.; Campbell, Esther; Mulberry, Gayle; Brady, Ann; Edmonds, Sarah L.; Arbogast, James W.

    2011-01-01

    A novel method has been developed for the evaluation of alcohol-based hand rubs (ABHR) that employs a hand contamination procedure that more closely simulates the in-use conditions of ABHR. Hands of human subjects were contaminated with 0.2 ml of a concentrated suspension of Serratia marcescens (ATCC 14756) to achieve baseline contamination between 8 and 9 log10 CFU/hand while allowing product to be applied to dry hands with minimal soil load. Evaluation of 1.5 ml of an ABHR gel containing 62% ethanol produced log10 reductions of 2.66 ± 0.96, 2.40 ± 0.50, 2.41 ± 0.61, and 2.33 ± 0.49 (means ± standard deviations) after 1, 3, 7, and 10 successive contamination/product application cycles. In a study comparing this low-volume contamination (LVC) method to ASTM E1174, product dry times were more realistic and log10 reductions achieved by the ABHR were significantly greater when LVC was employed (P < 0.05). These results indicate that a novel low-volume hand contamination procedure, which more closely represents ABHR use conditions, provides more realistic estimates of in-use ABHR efficacies. Based on the LVC method, log10 reductions produced by ABHR were strongly dependent on the test product application volume (P < 0.0001) but were not influenced by the alcohol concentration when it was within the range of 62 to 85% (P = 0.378). PMID:22003004

  16. Towards objective hand hygiene technique assessment: validation of the ultraviolet-dye-based hand-rubbing quality assessment procedure.

    PubMed

    Lehotsky, Á; Szilágyi, L; Bánsághi, S; Szerémy, P; Wéber, G; Haidegger, T

    2017-09-01

    Ultraviolet spectrum markers are widely used for hand hygiene quality assessment, although their microbiological validation has not been established. A microbiology-based assessment of the procedure was conducted. Twenty-five artificial hand models underwent initial full contamination, then disinfection with UV-dyed hand-rub solution, digital imaging under UV-light, microbiological sampling and cultivation, and digital imaging of the cultivated flora were performed. Paired images of each hand model were registered by a software tool, then the UV-marked regions were compared with the pathogen-free sites pixel by pixel. Statistical evaluation revealed that the method indicates correctly disinfected areas with 95.05% sensitivity and 98.01% specificity. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  17. Inefficacy of alcohol-based hand rub on mites in a patient with hyperkeratotic scabies.

    PubMed

    Cinotti, E; Perrot, J L; Labeille, B; Maguet, H; Couzan, C; Flori, P; Cambazard, F

    2015-03-01

    The World Health Organization is strongly promoting alcohol-based hand rubs to interrupt transmission of pathogens within the healthcare environment, and in some hospitals they are being recommended in cases of scabies. However, there are no studies that demonstrate the efficacy of such hand rubs against scabies. To evaluate the viability of Sarcoptes scabiei after the application of various topical antiseptics used for hand hygiene, and the effect of hand washing on the number of parasites present on the skin surface of a patient with scabies. We applied three different topical antiseptics (two alcohol-based and one povidone-iodine-based) to the skin of one hand that was affected by scabies, and took a skin scraping of each area to evaluate the viability of the mites over time. A skin scraping of a control area without antiseptic application was also taken. We also tested the antiseptics directly on the mites. Statistical comparison between the percentages of vital mites in the different samples was assessed using the χ(2) test. We also captured a dermoscopic image of the other hand before and after hand washing to count the number of parasites on the skin surface. Topical antiseptics did not reduce the number of living mites compared with control skin, and hand washing did not reduce the number of parasites on the skin surface. Application of topical antiseptics does not reduce the viability of S. scabiei, and is therefore unable to prevent the transmission of scabies. The usefulness of hand washing in preventing transmission of scabies to new subjects remains to be investigated. © 2014 British Association of Dermatologists.

  18. Comparative assessment of local tolerance of alcohols commonly used in alcohol-based hand rubs for hand hygiene.

    PubMed

    Manche, Monique; Foligné, Benoît; Sauty, Mathieu; Platel, Anne; Vercauteren, Eric; Rauwel, Gaétan; Catoire, Sophie; Ficheux, Hervé; Criquelion, Jacques; Nesslany, Fabrice

    2017-10-01

    Hand hygiene plays a key role in nosocomial infection prevention. To achieve users' adherence, products' dermal tolerance is essential. We aimed at making a comparative assessment of skin irritation and phototoxicity of the 3 alcohols commonly used in alcohol-based hand rubs (Ethanol, Propan-2-ol, Propan-1-ol) at 60, 70, 80 or 85% w/w in water or with co-formulates (hydrating, emollient and skin protective agents). In vitro validated OECD methods 439 and 432 were used. For irritation, EpiSkin™ Small Model was the chosen Reconstructed Human Epidermis (RhE). For phototoxicity, co-formulates alone or in mixture with and without alcohol were tested using BALB/c 3T3 cell cultures. Whilst Ethanol and Propan-2-ol could not be differentiated and displayed good skin tolerance profiles, Propan-1-ol based products lead to significant viability impairments of RhE at 60, 70 or 80% and at 60% in the presence of co-formulates. However, these results could not be reproduced in another RhE model. Taking also into account bibliographic data on Propan-1-ol, this suggests that our results are probably related to a lack of specificity of the used RhE. Therefore, it can be relevant in case of significant results to use two different RhE models before performing any classification and/or performing any complementary tests. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Prevalence of muzzle-rubbing and hand-rubbing behavior in wild chimpanzees in Mahale Mountains National Park, Tanzania.

    PubMed

    Corp, Nadia; Hayaki, Hitoshige; Matsusaka, Takahisa; Fujita, Shiho; Hosaka, Kazuhiko; Kutsukake, Nobuyuki; Nakamura, Michio; Nakamura, Miho; Nishie, Hitonaru; Shimada, Masaki; Zamma, Koichiro; Wallauer, William; Nishida, Toshisada

    2009-04-01

    In 1998, four chimpanzees in the Mahale Mountains National Park, Tanzania, were observed wiping their mouths with non-detached leaves or stalks of grass, or rubbing their mouths with a tree trunk or branch, especially while eating lemons. The number of mouth-wiping/rubbing individuals increased to 18 in 1999. By 2005, 29 chimpanzees were documented wiping/rubbing their muzzles in this way. Although it is difficult to determine whether the chimpanzees acquired this behavior as a result of trial and error or social learning, the fact that chimpanzees at other sites perform this behavior with detached leaves or leafy twigs much more often than with intact items suggests the possibility that cleaning with intact plant parts at Mahale spread via social learning.

  20. Hand Hygiene – Evaluation of Three Disinfectant Hand Sanitizers in a Community Setting

    PubMed Central

    Babeluk, Rita; Jutz, Sabrina; Mertlitz, Sarah; Matiasek, Johannes; Klaus, Christoph

    2014-01-01

    Hand hygiene is acknowledged as the single most important measure to prevent nosocomial infections in the healthcare setting. Similarly, in non-clinical settings, hand hygiene is recognised as a key element in helping prevent the spread of infectious diseases. The aim of this study was to evaluate the efficacy of three different disinfectant hand sanitizers in reducing the burden of bacterial hand contamination in 60 healthy volunteers in a community setting, both before and after education about the correct use of hand sanitizers. The study is the first to evaluate the efficacy and ease of use of different formulations of hand rubs used by the general population. The products tested were: Sterillium (perfumed, liquid), desderman pure gel (odorless, gel) and Lavit (perfumed, spray). Sterillium and desderman are EN1500 (hygienic hand rub) certified products (available in pharmacy) and Lavit is non EN1500 certified and available in supermarkets. The two EN1500 certified products were found to be significantly superior in terms of reducing bacterial load. desderman pure gel, Sterillium and Lavit reduced the bacterial count to 6.4%, 8.2% and 28.0% respectively. After education in the correct use of each hand rub, the bacterial load was reduced even further, demonstrating the value of education in improving hand hygiene. Information about the testers' perceptions of the three sanitizers, together with their expectations of a hand sanitizer was obtained through a questionnaire. Efficacy, followed by skin compatibility were found to be the two most important attributes of a hand disinfectant in our target group. PMID:25379773

  1. Outbreak of human metapneumovirus infection in psychiatric inpatients: implications for directly observed use of alcohol hand rub in prevention of nosocomial outbreaks.

    PubMed

    Cheng, V C C; Wu, A K L; Cheung, C H Y; Lau, S K P; Woo, P C Y; Chan, K H; Li, K S M; Ip, I K S; Dunn, E L W; Lee, R A; Yam, L Y C; Yuen, K Y

    2007-12-01

    Nosocomial outbreaks of infectious diseases in psychiatric facilities are not uncommon but the implementation of infection control measures is often difficult. Here, we report an outbreak of an acute respiratory illness in a psychiatric ward between 29 July and 20 August 2005 involving 31 patients. Human metapneumovirus was detected in seven (23%) patients by reverse transcription-polymerase chain reaction and nucleotide sequencing. A review of outbreak surveillance records showed that six nosocomial outbreaks occurred in the year 2005, of which four (67%) were confirmed or presumably related to a respiratory viral infection. Directly observed deliveries of alcohol hand rub 4-hourly during daytime to all psychiatric patients was instituted in December 2005. Only one nosocomial respiratory viral outbreak occurred in the following year. The total number of patients and staff involved in nosocomial outbreaks due to presumed or proven respiratory virus infections decreased significantly from 60 to six (P<0.001), whereas those due to all types of nosocomial outbreaks also decreased from 70 to 24 (P=0.004). Alcohol hand rub has been shown to have potent bactericidal and virucidal activity against a wide range of nosocomial pathogens. Regular use of directly observed alcohol hand rub may decrease the incidence and scale of nosocomial outbreaks due to enveloped respiratory viruses especially in mentally incapacitated patients.

  2. Better compliance and better tolerance in relation to a well-conducted introduction to rub-in hand disinfection.

    PubMed

    Girard, R; Amazian, K; Fabry, J

    2001-02-01

    The aim of the study was to demonstrate that the introduction of rub-in hand disinfection (RHD) in hospital units, with the implementation of suitable equipment, drafting of specific protocols, and training users, improved compliance of hand disinfection and tolerance of user's hands. In four hospital units not previously using RHD an external investigator conducted two identical studies in order to measure the rate of compliance with, and the quality of, disinfection practices, [rate of adapted (i.e., appropriate) procedures, rate of correct (i.e., properly performed) procedures, rate of adapted and correct procedures carried out] and to assess the state of hands (clinical scores of dryness and irritation, measuring hydration with a corneometer). Between the two studies, the units were equipped with dispensers for RHD products and staff were trained. Compliance improved from 62.2 to 66.5%, quality was improved (rate of adapted procedures from 66.8% to 84.3%, P > or = 10(-6), rate of correct procedures from 11.1% to 28.9%, P > or = 10(-8), rate of adapted and correct procedures from 6.0 to 17.8%, P > or = 10(-8)). The tolerance was improved significantly (P > or = 10(-2)) for clinical dryness and irritation scores, although not significantly for measurements using a corneometer. This study shows the benefit of introducing RHD with a technical and educational accompaniment. Copyright 2001 The Hospital Infection Society.

  3. Assessment of transpulmonary absorption of ethanol from alcohol-based hand rub.

    PubMed

    Hautemanière, Alexis; Ahmed-Lecheheb, Djihane; Cunat, Lisiane; Hartemann, Philippe

    2013-03-01

    Alcohol-based hand rubs (ABHRs) have been associated with a reduction of nosocomial infections. Despite the worldwide introduction of these products in health care settings, the aim of this study was to assess the transpulmonary absorption of ethanol contains in ABHRs used by health care workers (HCWs) in real conditions of work shift. Twenty-six HCWs of Nancy University Hospital were included. Research consisted in monitoring participants during 4 hours of work shift to assess their exposure to ethanol. The measurement of ethanol vapors in exhaled breath was performed using a class B ethylometer (Alco-Sensor FST). Ethanol concentration in inhaled breath was measured using Gilian pump LFS-113. Concentration of ethanol, acetaldehyde, and acetate in blood and urine samples were determined using gas chromatography with flame ionization detector. Participants were 12% male and 88% female. The mean age was 40 ± 8 years. None of the employees included in the study presented any traces of ethanol or its metabolites in the blood or urine. Ethanol (0.08 ± 0.07 mg/L) was detected in the breath of 10 HCWs at 1 to 2 minutes postexposure. The mean concentration of ethanol in the inhaled air was 46.2 mg/m. Absorption of ethanol vapor from ABHRs among HCWs during their care activities was not detected. Quantification of ethanol fumes inhaled during 4 hours of work shift was below the regulatory limitations of exposure to ethanol. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  4. A step-wise approach towards introduction of an alcohol based hand rub, and implementation of front line ownership- using a, rural, tertiary care hospital in central India as a model.

    PubMed

    Sharma, Megha; Joshi, Rita; Shah, Harshada; Macaden, Ragini; Lundborg, Cecilia Stålsby

    2015-04-29

    Appropriate hand hygiene is a gold standard to combat healthcare associated infections (HAIs). The World Health Organization (WHO) has recommended alcohol based hand rub (ABHR) as the most effective tool to maintain hand hygiene. In resource poor settings commercially available ABHR is not "economically accessible". The objectives of this study were to assess the acceptability of, and to build confidence for an in-house prepared (based on WHO guidelines) alcohol based hand rub among healthcare workers (HCWs) using a rural, tertiary care hospital in central India as an example. A series of activities were developed and conducted based on the Precede-Proceed model, the Trans Theoretical model of behaviour change, Front line ownership and Social marketing. A modified WHO-ABHR formulation, the 'test product' and 'WHO product evaluation form' were used for self assessment of acceptability of the 'test product'. Confidence building activities, as finger tip culture, visual portrayal method and handmade posters, were used in high-risk wards for HAIs, to build confidence for the 'test product' in removing transient flora from the hands. A locally developed feedback from was used to evaluate the impact of the activities conducted. Overall 183 HCWs were enrolled for the assessment of the 'test product' (130- doctors and 53 nurses). Out of these 83% (108/130) doctors and 94% (50/53) nurses were satisfied with the 'test product'. The confidence building activity was conducted with 116 participants (49 doctors). After single use of the 'test product', overall a significant reduction was observed for the CFUs on the blood agar plates (0.77 Log(10), p < 0.001). A complete reduction (100%) in colony forming units on incubated blood agar plates was seen for 13% (15/116) participants. Eighty two percent (95/116) participants expressed their confidence in the 'test product'. The self reported acceptance level for the 'test product' was high. The use of finger tip culture coupled

  5. Antibacterial Efficacy of Several Surgical Hand Preparation Products Used by Veterinary Students.

    PubMed

    Chou, Po-Yen; Doyle, Aimie J; Arai, Shiori; Burke, Pierre J; Bailey, Trina R

    2016-05-01

    To compare the antibacterial efficacy of different surgical hand antisepsis protocols used by veterinary students. Prospective, randomized, controlled study. Third year veterinary students (n=45). The participants were randomly assigned to 4 of the following 12 hand preparation product/time combinations: nonabrasive hand scrub method with 4% chlorhexidine gluconate (CH); hand rub with a mixture of 30% 1-propanol and 45% 2-propanol solution (MPS), 70% 2-propanol solution (IPS), or 61% ethanol solution with 1% chlorhexidine gluconate (ES/CH), with a contact time of 1.5, 3, or 5 minutes. Antibacterial efficacy was assessed after surgical hand preparation and at the end of surgery. Log reductions of total bacterial colony forming unit (CFU)/mL and positive aerobic culture rates were compared using multivariable analysis of variance and multivariable logistic regression, respectively. After surgical hand preparation, CH and ES/CH provided significantly higher log CFU reduction and lower positive culture rate for Gram-positive and spore-forming bacteria compared to MPS and IPS. Increase in contact time did not provide significant improvement in bacterial reduction. At the end of surgery, ES/CH provided significantly higher log CFU reduction compared to IPS and lower positive culture rate for Gram-positive bacteria compared to CH, MPS, and IPS. Increase in contact time significantly improved log CFU reduction in ES/CH and MPS groups. In our population of veterinary students ES/CH hand rubs or CH scrubs were more effective in reducing bacterial CFU during surgical hand preparation than MPS or IPS. © Copyright 2016 by The American College of Veterinary Surgeons.

  6. [The effectiveness of hand hygiene products on MRSA colonization of health care workers by using CHROMagar MRSA].

    PubMed

    Koçak Tufan, Zeliha; Irmak, Hasan; Bulut, Cemal; Cesur, Salih; Kınıklı, Sami; Demiröz, Ali Pekcan

    2012-04-01

    The aims of this study were; to investigate the hand hygiene compliance of the health care workers (HCWs) during their routine patient care, to determine the methicillin-resistant Staphylococcus aureus (MRSA) hand colonization of the HCWs, to investigate the effect of different hand hygiene products on MRSA colonization and to evaluate the effectiveness of chromogenic agar for detecting MRSA. HCWs were investigated during their routine patient care and hand cultures were taken before and after hand wash/hygiene. Two different techniques were used to obtain the hand cultures: fingertip method (CHROMagar MRSA containing HygiSlide); and direct swab method and then inoculation to CHROMagar MRSA media. MRSA strains grown on those cultures were confirmed with conventional methods. A total of 100 HCWs (of them 61 were female; mean age: 32.7 ± 5.2 years; age range: 25-51 years) involving physicians (n= 33), nurses (n= 38) and health care assistants (n= 29), were included in the study. MRSA was detected in 39% and 11% before hand hygiene and in 13% and 6% after hand hygiene, with HygiSlide CHROMagar media and with CHROMagar in plate media, respectively. No difference were found regarding clinics, occupations, or the type of patient handling in those HCWs who were positive (n= 13) for MRSA colonization following hand hygiene, and those who were negative (n= 26). However, the type of the hand hygiene product used exhibited a statistical difference. None of the seven HCWs who used alcohol based hand rub revealed growth in the second culture while 10 of 19 (53%) HCWs who used soap and three of 13 (23%) HCWs who used chlorhexidine were still colonized with MRSA. In terms of reduction in the MRSA counts, the most effective one was the alcohol based hand rub while the soap was the least, since seven of 19 (37%) HCWs who used soap showed no reduction at all in the MRSA counts. A high ratio of hand colonization with MRSA was detected in our hospital staff (39%). It was shown that

  7. Compressor seal rub energetics study

    NASA Technical Reports Server (NTRS)

    Laverty, W. F.

    1978-01-01

    The rub mechanics of compressor abradable blade tip seals at simulated engine conditions were investigated. Twelve statistically planned, instrumented rub tests were conducted with titanium blades and Feltmetal fibermetal rubstrips. The tests were conducted with single stationary blades rubbing against seal material bonded to rotating test disks. The instantaneous rub torque, speed, incursion rate and blade temperatures were continuously measured and recorded. Basic rub parameters (incursion rate, rub depth, abradable density, blade thickness and rub velocity) were varied to determine the effects on rub energy and heat split between the blade, rubstrip surface and rub debris. The test data was reduced, energies were determined and statistical analyses were completed to determine the primary and interactive effects. Wear surface morphology, profile measurements and metallographic analysis were used to determine wear, glazing, melting and material transfer. The rub energies for these tests were most significantly affected by the incursion rate while rub velocity and blade thickness were of secondary importance. The ratios of blade wear to seal wear were representative of those experienced in engine operation of these seal system materials.

  8. Adequate Hand Washing and Glove Use Are Necessary To Reduce Cross-Contamination from Hands with High Bacterial Loads.

    PubMed

    Robinson, Andrew L; Lee, Hyun Jung; Kwon, Junehee; Todd, Ewen; Rodriguez, Fernando Perez; Ryu, Dojin

    2016-02-01

    Hand washing and glove use are the main methods for reducing bacterial cross-contamination from hands to ready-to-eat food in a food service setting. However, bacterial transfer from hands to gloves is poorly understood, as is the effect of different durations of soap rubbing on bacterial reduction. To assess bacterial transfer from hands to gloves and to compare bacterial transfer rates to food after different soap washing times and glove use, participants' hands were artificially contaminated with Enterobacter aerogenes B199A at ∼9 log CFU. Different soap rubbing times (0, 3, and 20 s), glove use, and tomato dicing activities followed. The bacterial counts in diced tomatoes and on participants' hands and gloves were then analyzed. Different soap rubbing times did not significantly change the amount of bacteria recovered from participants' hands. Dicing tomatoes with bare hands after 20 s of soap rubbing transferred significantly less bacteria (P < 0.01) to tomatoes than did dicing with bare hands after 0 s of soap rubbing. Wearing gloves while dicing greatly reduced the incidence of contaminated tomato samples compared with dicing with bare hands. Increasing soap washing time decreased the incidence of bacteria recovered from outside glove surfaces (P < 0.05). These results highlight that both glove use and adequate hand washing are necessary to reduce bacterial cross-contamination in food service environments.

  9. Hand rub dose needed for a single disinfection varies according to product: a bias in benchmarking using indirect hand hygiene indicator.

    PubMed

    Girard, Raphaële; Aupee, Martine; Erb, Martine; Bettinger, Anne; Jouve, Alice

    2012-12-01

    The 3ml volume currently used as the hand hygiene (HH) measure has been explored as the pertinent dose for an indirect indicator of HH compliance. A multicenter study was conducted in order to ascertain the required dose using different products. The average contact duration before drying was measured and compared with references. Effective hand coverage had to include the whole hand and the wrist. Two durations were chosen as points of reference: 30s, as given by guidelines, and the duration validated by the European standard EN 1500. Each product was to be tested, using standardized procedures, by three nosocomial infection prevention teams, for three different doses (3, 2 and 1.5ml). Data from 27 products and 1706 tests were analyzed. Depending on the product, the dose needed to ensure a 30-s contact duration in 75% of tests ranging from 2ml to more than 3ml, and to ensure a contact duration exceeding the EN 1500 times in 75% of tests ranging from 1.5ml to more than 3ml. The aftermath interpretation is the following: if different products are used, the volume utilized does not give an unbiased estimation of the HH compliance. Other compliance evaluation methods remain necessary for efficient benchmarking. Copyright © 2012 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.

  10. Back to basics: hand hygiene and surgical hand antisepsis.

    PubMed

    Spruce, Lisa

    2013-11-01

    Health care-associated infections (HAIs) are a significant issue in the United States and throughout the world, but following proper hand hygiene practices is the most effective and least expensive way to prevent HAIs. Hand hygiene is inexpensive and protects patients and health care personnel alike. The four general types of hand hygiene that should be performed in the perioperative environment are washing hands that are visibly soiled, hand hygiene using alcohol-based products, surgical hand scrubs, and surgical hand scrubs using an alcohol-based surgical hand rub product. Barriers to proper hand hygiene may include not thinking about it, forgetting, skin irritation, a lack of role models, or a lack of a safety culture. One strategy for improving hand hygiene practices is monitoring hand hygiene as part of a quality improvement project, but the most important aspect for perioperative team members is to set an example for other team members by following proper hand hygiene practices and reminding each other to perform hand hygiene. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  11. Evaluating the tolerability and acceptability of an alcohol-based hand rub - real-life experience with the WHO protocol.

    PubMed

    Wolfensberger, Aline; Durisch, Nina; Mertin, Juliane; Ajdler-Schaeffler, Evelyne; Sax, Hugo

    2015-01-01

    Optimizing user satisfaction with alcohol-based hand rubs (ABHR) may be vital to enhance hand hygiene performance. This study tested the tolerability and acceptability of a new ABHR (EVO9; Ecolab) in healthcare workers under daily working conditions and evaluated the practicability of the corresponding WHO protocol. We strictly applied the WHO single product ABHR evaluation protocol. A trained observer assessed hand skin conditions of healthy volunteers using at least 30 ml ABHR per day during their clinical work at baseline, day 3-5 and one month (visit 1-3). Participants rated ABHR tolerability and acceptability at visit 2 and 3. Additionally, we registered study time for participants and study team. Among 46 volunteers, 76% were female; 37% nurses, 28% physicians. Skin was observer-rated "not" or "incidentally" dry in 64.4%, 77.8%, and 90.9% participants at visit 1, 2, and 3, respectively. EVO9 was scored ≥5 (progressive scale, 1-7) for appearance, intactness, moisture content, and sensation by 95.7%, 97.7%, 88.9%, and 97.8% participants at visit 3, respectively. All WHO benchmarks were exceeded except for "speed of drying" at visit 2, and "texture" at visit 2 and 3. Cumulative study time expenditure was 14 days for the observer and four days for participants. EVO9 was well tolerated and accepted according to the WHO single ABHR evaluation protocol with the potential for improvement for stickiness. The WHO protocol is feasible but requires considerable time and logistics. It does not preclude bias, in this case especially due to the necessary switch to personal dispensers.

  12. Neonatal ethanol exposure from ethanol-based hand sanitisers in isolettes.

    PubMed

    Hsieh, Shizuka; Sapkota, Amir; Wood, Rebecca; Bearer, Cynthia; Kapoor, Shiv

    2018-01-01

    The aims of this study is to measure the ethanol vapours in the isolette after use of hands cleaned with ethanol-based hand sanitiser (EBHS). Two squirts (1.5 mL) of hand sanitiser were rubbed on hands for 10 or 20 s before inserting the hands in the isolette for 5 min. Ethanol vapours were measured in the isolette with photoionisation detector and alcohol breathalyser for 30 min. Peak ethanol concentration in the isolette was considerably higher with a 10 s hand rub (381±192 ppm) compared with a 20 s hand rub (99±50 ppm), and dissipated to ≤5 ppm within 30 min. Under routine care, EBHS use by care providers exposes neonates in isolettes to 3.7-7.3 or 1.4-2.8 mg/kg ethanol per day with 10 or 20 s hand rubs, respectively. The expected blood level from average single exposure is 0.036 mg/dL with 10 s hand rub and may increase further with multiple exposures in a short period. Preterm neonates in the isolette are at risk of inadvertent exposure to ethanol. The expected blood alcohol level from this exposure is small and below 1 mg/dL level recommended by European Medicines Agency to limit the ethanol exposure in children. The unintended ethanol exposure can be avoided by rubbing hands for at least 20 s after applying EBHS. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Modeling multi-scale resource selection for bear rub trees in northwestern Montana

    USGS Publications Warehouse

    Morgan Henderson, Matthew J.; Hebblewhite, Mark; Mitchell, Michael S.; Stetz, Jeffrey B.; Kendall, Katherine C.; Carlson, Ross T.

    2015-01-01

    Both black (Ursus americanus) and grizzly bears (U. arctos) are known to rub on trees and other objects, producing a network of repeatedly used and identifiable rub sites. In 2012, we used a resource selection function to evaluate hypothesized relationships between locations of 887 bear rubs in northwestern Montana, USA, and elevation, slope angle, density of open roads and distance from areas of heightened plant-productivity likely containing forage for bears. Slope and density of open roads were negatively correlated with rub presence. No other covariates were supported as explanatory variables. We also hypothesized that bear rubs would be more strongly associated with closed roads and developed trails than with game trails. The frequencies of bear rubs on 30 paired segments of developed tracks and game trails were not different. Our results suggest bear rubs may be associated with bear travel routes, and support their use as “random” sampling devices for non-invasive spatial capture–recapture population monitoring.

  14. Practice of skin protection and skin care among German surgeons and influence on the efficacy of surgical hand disinfection and surgical glove perforation

    PubMed Central

    2014-01-01

    Background Surgical hand rub and healthy skin are basic requirements to prevent surgical site infections. Nevertheless, there is little knowledge about the current practice of skin protection and/or skin care products (SP/SC) using among surgeons as well as a lack of data pertaining to the influence of SP/SC on the antimicrobial efficacy of surgical hand rub. Methods A 10 weeks-survey among German surgeons as well as an experimental crossover study involving 26 participants were conducted. The immediate and sustainable efficacy (IE/SE) of surgical hand rub and participants’ hand moisture were measured after an 8-day usage of SP/SC, as well as the influence on micro-perforations on surgical gloves. Results The questionnaire was available to 16,000 German surgeons. Thereof, 1,771 surgeons accessed the questionnaire, representing a total participation rate of 11%. As 19% (n = 338) of questionnaires were incomplete, a total of 1,433 completed questionnaires were available for further analysis. More than 75% of the participants stated not to use any SP/SC, yet, almost 50% suffered from skin irritation or discomfort. Only 5% used SP/SC at the beginning of their shift. 10% refused to use SP/SC because of concerns that SP/SC may reduce the antimicrobial efficacy of surgical hand rub. After usage of SP/SC over 8-days, skin moisture was significantly higher (P < 0.001), whereas no significant influence on the antimicrobial efficacy of surgical hand rub was observed (IE: P = 0.135; SP: P = 0.681). Micro-perforations were detected in 8/52 surgical gloves (15%), with no statistical significant difference between SP/SC users (n = 2/26; 8%) and non-users (n = 6/26; 23%; P = 0.249). Conclusions Following the results of this largest questionnaire base survey among German surgeons on skin care, there is a need to educate and inform surgeons on the correct application and the concept of SP/SC strategies. In the present study, the combination of selected

  15. Hand hygiene--comparison of international recommendations.

    PubMed

    Wendt, C

    2001-08-01

    The value of hand hygiene for the prevention of cross-infection was first observed in the middle of the 19th century. Since then, which procedure is the most suitable for hand hygiene has been repeatedly discussed and several different guidelines and recommendations have been published. The aim of this review is to compare different recommendations for hand hygiene regarding technique and indication. Medline, the internet and a personal library were searched to obtain as many written recommendations as possible. In addition, a small questionnaire was sent by e-mail to 20 international colleagues. As a result, written recommendations from 10 countries could be compared. Recommended methods of hand hygiene include handwashing (washing hands with plain soap), hygienic handwash (washing hands with medicated soap) and hygienic hand-rub (use of antiseptic rubs). In most countries handwashing and hygienic handwash are the methods of choice and only in central European countries is hygienic hand-rub the preferred technique. Situations in which performance of hand hygiene is recommended are comparable. However, no single indication is recommended in all guidelines. Hand hygiene is most often recommended before performing invasive procedures and after microbial contamination. Guidelines should be clear and easy to follow for them to become standard of care. Thus, guidelines are needed that do not leave to the health care worker a decision as to whether hand hygiene is indicated.

  16. Implementing AORN recommended practices for hand hygiene.

    PubMed

    Patrick, Marcia; Van Wicklin, Sharon A

    2012-04-01

    This article focuses on implementing the revised AORN "Recommended practices for hand hygiene in the perioperative setting." The content of the document has been expanded and reorganized from the previous iteration and now includes specific activity statements about water temperature, water and soap dispensing controls, the type of dispensers to use, paper towel dispenser requirements, placement of soap and rub dispensers, and regulatory requirements for products and recommendations for hand hygiene practices. A successful hand hygiene program allows end users to have input into the selection and evaluation of products and should include educating personnel about proper hand hygiene, product composition and safety, and how and when to use specific products. Measures for competency evaluation and compliance monitoring include observations, quizzes, skills labs, electronic monitoring systems, handheld device applications, and data collection forms. Copyright © 2012 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  17. Rubbing ointments and asthma morbidity in adolescents.

    PubMed

    Reznik, Marina; Sharif, Iman; Ozuah, Philip O

    2004-12-01

    To determine the relationship between the use of rubbing ointments and asthma morbidity in adolescents. Cross-sectional study. Inner-city high school in the Bronx, New York. 165 adolescents with asthma. Asthma morbidity, defined as emergency department (ED) use for asthma in the past year and over the lifetime. While 127 (77%) of subjects used albuterol as the first treatment for their last asthma attack, 18 (11%) used rubbing ointments. The rubs and albuterol groups were similar in asthma severity, mean age, gender, and ethnicity. However, subjects in the the rubs group were less likely than subjects in the albuterol group to have made an ED visit over the past 12 months or over their lifetime. Regression analysis revealed that, after controlling for asthma severity, use of rubs independently predicted less lifetime ED use. After controlling for asthma severity, use of rubs by adolescents with asthma was associated with lower asthma morbidity as measured by ED use.

  18. Blade Tip Rubbing Stress Prediction

    NASA Technical Reports Server (NTRS)

    Davis, Gary A.; Clough, Ray C.

    1991-01-01

    An analytical model was constructed to predict the magnitude of stresses produced by rubbing a turbine blade against its tip seal. This model used a linearized approach to the problem, after a parametric study, found that the nonlinear effects were of insignificant magnitude. The important input parameters to the model were: the arc through which rubbing occurs, the turbine rotor speed, normal force exerted on the blade, and the rubbing coefficient of friction. Since it is not possible to exactly specify some of these parameters, values were entered into the model which bracket likely values. The form of the forcing function was another variable which was impossible to specify precisely, but the assumption of a half-sine wave with a period equal to the duration of the rub was taken as a realistic assumption. The analytical model predicted resonances between harmonics of the forcing function decomposition and known harmonics of the blade. Thus, it seemed probable that blade tip rubbing could be at least a contributor to the blade-cracking phenomenon. A full-scale, full-speed test conducted on the space shuttle main engine high pressure fuel turbopump Whirligig tester was conducted at speeds between 33,000 and 28,000 RPM to confirm analytical predictions.

  19. Influence of rubbing on rotor dynamics, part 1

    NASA Technical Reports Server (NTRS)

    Muszynska, Agnes; Bently, Donald E.; Franklin, Wesley D.; Hayashida, Robert D.; Kingsley, Lori M.; Curry, Arthur E.

    1989-01-01

    The results of analytical and experimental research on rotor-to-stationary element rubbing in rotating machines are presented. A characterization of physical phenomena associated with rubbing, as well as a literature survey on the subject of rub is given. The experimental results were obtained from two rubbing rotor rigs: one, which dynamically simulates the space shuttle main engine high pressure fuel turbopump (HPFTP), and the second one, much simpler, a two-mode rotor rig, designed for more generic studies on rotor-to-stator rubbing. Two areas were studied: generic rotor-to-stator rub-related dynamic phenomena affecting rotating machine behavior and applications to the space shuttle HPFTP. An outline of application of dynamic stiffness methodology for identification of rotor/bearing system modal parameters is given. The mathematical model of rotor/bearing/seal system under rub condition is given. The computer program was developed to calculate rotor responses. Compared with experimental results the computed results prove an adequacy of the model.

  20. Assessment of hand hygiene techniques using the World Health Organization's six steps.

    PubMed

    Arias, Ariadna V; Garcell, Humberto G; Ochoa, Yagdeline R; Arias, Katiana F; Miranda, Fernando R

    2016-01-01

    The quality of hand hygiene was evaluated via direct observation for compliance with the six recommended World Health Organization steps. A total of 2497 HH opportunities, of which 1573 (63.0%) were hand rubs, were monitored over a five month period. Compliance was higher in nurses compared with physicians and auxiliaries and in steps 1 and 2 for hand rubs as well as the first three steps of hand washing, with lower rates after these steps. Rubbing of the thumbs and fingertips achieved the lowest rates of compliance in both HH types. A combination of the five recommended moments and six steps and staff education is recommended to improve the quality of hand hygiene. Copyright © 2015 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  1. Recognition and Cleavage of Related to Ubiquitin 1 (Rub1) and Rub1-Ubiquitin Chains by Components of the Ubiquitin-Proteasome System*

    PubMed Central

    Singh, Rajesh K.; Zerath, Sylvia; Kleifeld, Oded; Scheffner, Martin; Glickman, Michael H.; Fushman, David

    2012-01-01

    Of all ubiquitin-like proteins, Rub1 (Nedd8 in mammals) is the closest kin of ubiquitin. We show via NMR that structurally, Rub1 and ubiquitin are fundamentally similar as well. Despite these profound similarities, the prevalence of Rub1/Nedd8 and of ubiquitin as modifiers of the proteome is starkly different, and their attachments to specific substrates perform different functions. Recently, some proteins, including p53, p73, EGFR, caspase-7, and Parkin, have been shown to be modified by both Rub1/Nedd8 and ubiquitin within cells. To understand whether and how it might be possible to distinguish among the same target protein modified by Rub1 or ubiquitin or both, we examined whether ubiquitin receptors can differentiate between Rub1 and ubiquitin. Surprisingly, Rub1 interacts with proteasome ubiquitin-shuttle proteins comparably to ubiquitin but binds more weakly to a proteasomal ubiquitin receptor Rpn10. We identified Rub1-ubiquitin heteromers in yeast and Nedd8-Ub heteromers in human cells. We validate that in human cells and in vitro, human Rub1 (Nedd8) forms chains with ubiquitin where it acts as a chain terminator. Interestingly, enzymatically assembled K48-linked Rub1-ubiquitin heterodimers are recognized by various proteasomal ubiquitin shuttles and receptors comparably to K48-linked ubiquitin homodimers. Furthermore, these heterologous chains are cleaved by COP9 signalosome or 26S proteasome. A derubylation function of the proteasome expands the repertoire of its enzymatic activities. In contrast, Rub1 conjugates may be somewhat resilient to the actions of other canonical deubiquitinating enzymes. Taken together, these findings suggest that once Rub1/Nedd8 is channeled into ubiquitin pathways, it is recognized essentially like ubiquitin. PMID:23105008

  2. Modeling the rubbing contact in honeycomb seals

    NASA Astrophysics Data System (ADS)

    Fischer, Tim; Welzenbach, Sarah; Meier, Felix; Werner, Ewald; kyzy, Sonun Ulan; Munz, Oliver

    2018-03-01

    Metallic honeycomb labyrinth seals are commonly used as sealing systems in gas turbine engines. Because of their capability to withstand high thermo-mechanical loads and oxidation, polycrystalline nickel-based superalloys, such as Hastelloy X and Haynes 214, are used as sealing material. In addition, these materials must exhibit a tolerance against rubbing between the rotating part and the stationary seal component. The tolerance of the sealing material against rubbing preserves the integrity of the rotating part. In this article, the rubbing behavior at the rotor-stator interface is considered numerically. A simulation model is incorporated into the commercial finite element code ABAQUS/explicit and is utilized to simulate a simplified rubbing process. A user-defined interaction routine between the contact surfaces accounts for the thermal and mechanical interfacial behavior. Furthermore, an elasto-plastic constitutive material law captures the extreme temperature conditions and the damage behavior of the alloys. To validate the model, representative quantities of the rubbing process are determined and compared with experimental data from the literature. The simulation results correctly reproduce the observations made on a test rig with a reference stainless steel material (AISI 304). A parametric study using the nickel-based superalloys reveals a clear dependency of the rubbing behavior on the sliding and incursion velocity. Compared to each other, the two superalloys studied exhibit a different rubbing behavior.

  3. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Rubbing alcohol general-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS DISTRIBUTION AND USE OF DENATURED ALCOHOL AND RUM...

  4. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Rubbing alcohol general-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS DISTRIBUTION AND USE OF DENATURED ALCOHOL AND RUM...

  5. Nudging to improve hand hygiene.

    PubMed

    Caris, M G; Labuschagne, H A; Dekker, M; Kramer, M H H; van Agtmael, M A; Vandenbroucke-Grauls, C M J E

    2018-04-01

    Hand hygiene is paramount to prevent healthcare-associated infections, but improving compliance is challenging. When healthcare workers seldom encounter healthcare-associated infections, they will consider the odds of causing infections through poor hand hygiene negligible. Cognitive biases such as these may induce non-compliance. Nudging, 'a friendly push to encourage desired behaviour', could provide an easily implemented, inexpensive measure to address cognitive biases and thus support hand hygiene interventions. To investigate whether behavioural nudges, displayed as posters, can increase the use of alcohol-based hand rub. We developed nudges based on a systematic review of previously described cognitive biases, and tested these through a cross-sectional survey among the target audience. We then conducted a controlled before-after trial on two hospital wards, to assess the effect of these nudges on the use of alcohol-based hand rub, measured with electronic dispensers. Poisson regression analyses adjusted for workload showed that nudges displayed next to dispensers increased their overall use on one ward [poster 1: relative risk: 1.6 (95% confidence interval: 1.2-2.2); poster 2: 1.7 (1.2-2.5)] and during doctor's rounds on both wards [poster 1: ward A: 1.7 (1.1-2.6); ward B: 2.2 (1.3-3.8)]. Use of dispensers without adjacent nudges did not increase. Nudges based on cognitive biases that play a role in hand hygiene, and displayed as posters, could provide an easy, inexpensive measure to increase use of alcohol-based hand rub. When applying nudges to change behaviour, it is important to identify the right nudge for the right audience. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  6. Less and less-influence of volume on hand coverage and bactericidal efficacy in hand disinfection.

    PubMed

    Kampf, Günter; Ruselack, Sigunde; Eggerstedt, Sven; Nowak, Nicolas; Bashir, Muhammad

    2013-10-10

    Some manufacturers recommend using 1.1 mL per application of alcohol-based handrubs for effective hand disinfection. However, whether this volume is sufficient to cover both hands, as recommended by the World Health Organization, and fulfills current efficacy standards is unknown. This study aimed to determine hand coverage for three handrubs (two gels based on 70% v/v and 85% w/w ethanol and a foam based on 70% v/v ethanol) applied at various volumes. Products were tested at product volumes of 1.1 mL, 2 mL, 2.4 mL as well as 1 and 2 pump dispenser pushes; the foam product was tested in addition at foam volumes of 1.1 mL, 2 mL, and 2.4 mL. Products were supplemented with a fluorescent dye and 15 participants applied products using responsible application techniques without any specific steps but the aim of completely covering both hands. Coverage quality was determined under ultraviolet light by two blinded investigators. Efficacy of the three handrubs was determined according to ASTM E 1174-06 and ASTM E 2755-10. For each experiment, the hands of 12 participants were contaminated with Serratia marcescens and the products applied as recommended (1.1 mL for 70% v/v ethanol products; 2 mL for the 85% w/w ethanol product). Log10-reduction was calculated. Volumes < 2 mL yielded high rates of incomplete coverage (67%-87%) whereas volumes ≥ 2 mL gave lower rates (13%-53%). Differences in coverage were significant between the five volumes tested for all handrubs (p < 0.001; two-way ANOVA) but not between the three handrubs themselves (p = 0.796). Application of 1.1 mL of 70% v/v ethanol rubs reduced contamination by 1.85 log10 or 1.60 log10 (ASTM E 1174-06); this failed the US FDA efficacy requirement of at least 2 log10. Application of 2 mL of the 85% w/w ethanol rub reduced contamination by 2.06 log10 (ASTM E 1174-06), fulfilling the US FDA efficacy requirement. Similar results were obtained according to ASTM E 2755-10. Our data indicated that

  7. Less and less–influence of volume on hand coverage and bactericidal efficacy in hand disinfection

    PubMed Central

    2013-01-01

    Background Some manufacturers recommend using 1.1 mL per application of alcohol-based handrubs for effective hand disinfection. However, whether this volume is sufficient to cover both hands, as recommended by the World Health Organization, and fulfills current efficacy standards is unknown. This study aimed to determine hand coverage for three handrubs (two gels based on 70% v/v and 85% w/w ethanol and a foam based on 70% v/v ethanol) applied at various volumes. Methods Products were tested at product volumes of 1.1 mL, 2 mL, 2.4 mL as well as 1 and 2 pump dispenser pushes; the foam product was tested in addition at foam volumes of 1.1 mL, 2 mL, and 2.4 mL. Products were supplemented with a fluorescent dye and 15 participants applied products using responsible application techniques without any specific steps but the aim of completely covering both hands. Coverage quality was determined under ultraviolet light by two blinded investigators. Efficacy of the three handrubs was determined according to ASTM E 1174-06 and ASTM E 2755-10. For each experiment, the hands of 12 participants were contaminated with Serratia marcescens and the products applied as recommended (1.1 mL for 70% v/v ethanol products; 2 mL for the 85% w/w ethanol product). Log10-reduction was calculated. Results Volumes < 2 mL yielded high rates of incomplete coverage (67%–87%) whereas volumes ≥ 2 mL gave lower rates (13%–53%). Differences in coverage were significant between the five volumes tested for all handrubs (p < 0.001; two-way ANOVA) but not between the three handrubs themselves (p = 0.796). Application of 1.1 mL of 70% v/v ethanol rubs reduced contamination by 1.85 log10 or 1.60 log10 (ASTM E 1174-06); this failed the US FDA efficacy requirement of at least 2 log10. Application of 2 mL of the 85% w/w ethanol rub reduced contamination by 2.06 log10 (ASTM E 1174-06), fulfilling the US FDA efficacy requirement. Similar results were obtained according to ASTM E 2755

  8. Quantitative impact of direct, personal feedback on hand hygiene technique.

    PubMed

    Lehotsky, Á; Szilágyi, L; Ferenci, T; Kovács, L; Pethes, R; Wéber, G; Haidegger, T

    2015-09-01

    This study investigated the effectiveness of targeting hand hygiene technique using a new training device that provides objective, personal and quantitative feedback. One hundred and thirty-six healthcare workers in three Hungarian hospitals participated in a repetitive hand hygiene technique assessment study. Ultraviolet (UV)-labelled hand rub was used at each event, and digital images of the hands were subsequently taken under UV light. Immediate objective visual feedback was given to participants, showing missed areas on their hands. The rate of inadequate hand rubbing reduced from 50% to 15% (P < 0.001). However, maintenance of this reduced rate is likely to require continuous use of the electronic equipment. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. Anti-bacterial efficacy of alcoholic hand rubs in the Kenyan market, 2015.

    PubMed

    Ochwoto, Missiani; Muita, Lucy; Talaam, Keith; Wanjala, Cecilia; Ogeto, Frank; Wachira, Faith; Osman, Saida; Kimotho, James; Ndegwa, Linus

    2017-01-01

    Hand hygiene is known to be effective in preventing hospital and community-acquired infections. The increasing number of hand sanitizer brands in Kenyan hospitals and consumer outlets is of concern. Thus the main aim of this study was to evaluate the anti-bacterial efficacy and organoleptic properties of these hand sanitizers in Kenya. This was an experimental, laboratory-based study of 14 different brands of hand sanitizers (coded HS1-14) available in various retail outlets and hospitals in Kenya. Efficacy was evaluated using standard non-pathogenic Escherichia coli (ATCC 25922), Staphylococcus aureus (ATCC 25923) and Pseudomonas aeruginosa (ATCC 27853) as per the European Standard (EN). The logarithmic reduction factors (RF) were assessed at baseline and after treatment, and log reduction then calculated. Ten and 25 healthy volunteers participated in the efficacy and organoleptic studies respectively. Four (28.6%) hand sanitizers (HS12, HS9, HS13 and HS14) showed a 5.9 reduction factor on all the three bacteria strains. Seven (50%) hand sanitizers had efficacies of <3 against all the three bacteria strains used. Efficacy on E. Coli was higher compared to the other pathogens. Three hand sanitizers were efficacious on one of the pathogens and not the other. In terms of organoleptic properties, gel-based formulations were rated far higher than the liquid based formulations brands. Fifty percent (50%) of the selected hand sanitizers in the Kenyan market have efficacy that falls below the World Health Organization (WHO) and DIN EN 1500:2013. Of the 14 hand sanitizers found in the Kenyan market, only four showed efficacies that were comparable to the WHO-formulation. There is a need to evaluate how many of these products with <3 efficacy that have been incorporated into the health system for hand hygiene and the country's policy on regulations on their usage.

  10. Mechanisms of rubbing-related corneal trauma in keratoconus.

    PubMed

    McMonnies, Charles W

    2009-07-01

    Corneal scarring in keratoconus, which is observed prior to contact lens wear and in association with a chronic habit of abnormal rubbing, suggests a keratocyte change to a repair phenotype in response to rubbing trauma. This review examines known and putative mechanisms for rubbing-related corneal trauma and cone formation. Responses to eye rubbing (and possible causal links) may include increased corneal temperature, epithelial thinning, increased concentrations of inflammatory mediators in the precorneal tears, abnormal enzyme activity, large intraocular pressure spikes, high hydrostatic tissue pressure, thixotropically reduced ground substance viscosity, temporary displacement of ground substance from the corneal apex, buckling and flexure of fibrils associated with waves of corneal indentation, biomechanically coupled curvature transfer to the cone apex, slippage between collagen fibrils at the cone apex, and changes to keratocytes due to mechanical trauma and/or high hydrostatic pressure, in addition to scar formation. Cone formation appears to depend on a loss of shear strength and may be a consequence of a reduction in ground substance viscosity and glue function, which could allow the cornea to bend and yield to intraocular pressure. For some forms of keratoconus, a reduction in shear strength and cone-forming deformation may be responses to rubbing trauma. Some of the mechanisms for corneal rubbing trauma may be relevant to post-laser-assisted in situ keratomileusis ectasia or complications following other types of corneal surgery. There appear to be indications for the control of chronic habits of abnormal rubbing.

  11. Hand hygiene for the prevention of nosocomial infections.

    PubMed

    Kampf, Günter; Löffler, Harald; Gastmeier, Petra

    2009-10-01

    The WHO regards hand hygiene as an essential tool for the prevention of nosocomial infection, but compliance in clinical practice is often low. The relevant scientific literature and national and international evidence-based recommendations (Robert Koch Institute [Germany], WHO) were evaluated. Hygienic hand disinfection has better antimicrobial efficacy than hand-washing and is the procedure of choice to be performed before and after manual contact with patients. The hands should be washed, rather than disinfected, only when they are visibly soiled. Skin irritation is quite common among healthcare workers and is mainly caused by water, soap, and prolonged wearing of gloves. Compliance can be improved by training, by placing hand-rub dispensers at the sites where they are needed, and by physicians setting a good example for others. Improved compliance in hand hygiene, with proper use of alcohol-based hand rubs, can reduce the nosocomial infection rate by as much as 40%.

  12. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light...

  13. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light...

  14. Rubbings deposited by cats elicit defensive behavior in rats.

    PubMed

    May, Matthew D; Bowen, Michael T; McGregor, Iain S; Timberlake, William

    2012-12-05

    Laboratory rats display pronounced defensive behaviors when confronted with a range of cat-derived stimuli, including collars worn by a cat, cloths rubbed on a cat, and cat fur. One possible explanation of this phenomenon (the "kairomone hypothesis") is that rats derive a survival advantage by eavesdropping on signals used by cats to communicate with each other. Cats are known to rub their bodies on objects at strategic environmental locations to signal their identity and mating potential to other cats. The current study assessed the sensitivity of laboratory rats to these body rubbings. In Experiment 1, food deprived Sprague-Dawley rats were trained to consume food pellets in one arm of a Y maze. On test day a damp cloth was placed near the food pellets that had been rubbed on a location (wall) where a cat had recently engaged in body rubbing. A control cloth and a collar worn by the cat were also tested. The presence of both the body rubbing residue and the cat collar increased latency to eat and decreased amount of food eaten. The disruption of consummatory behavior in the test environment was still evident 24h later in the absence of odor stimuli. Experiment 2 tested the reaction of naïve Wistar rats to body rubbings using a paradigm in which rats were given the opportunity to hide. Relative to a control condition, rats exposed to a cotton pad wiped on a cat body rubbing location showed increased hiding behavior, decreased exploration and reduced stimulus approach and investigation. These defensive responses persisted for up to 4days following a single stimulus exposure. These results suggest that rats eavesdrop readily on body rubbings cats use for identification purposes, providing further support for a kairomone hypothesis of predator odor avoidance. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Numerical investigations on axial and radial blade rubs in turbo-machinery

    NASA Astrophysics Data System (ADS)

    Abdelrhman, Ahmed M.; Tang, Eric Sang Sung; Salman Leong, M.; Al-Qrimli, Haidar F.; Rajamohan, G.

    2017-07-01

    In the recent years, the clearance between the rotor blades and stator/casing had been getting smaller and smaller prior improving the aerodynamic efficiency of the turbomachines as demand in the engineering field. Due to the clearance reduction between the blade tip and the rotor casing and between rotor blades and stator blades, axial and radial blade rubbing could be occurred, especially at high speed resulting into complex nonlinear vibrations. The primary aim of this study is to address the blade axial rubbing phenomenon using numerical analysis of rotor system. A comparison between rubbing caused impacts of axial and radial blade rubbing and rubbing forces are also aims of this study. Tow rotor models (rotor-stator and rotor casing models) has been designed and sketched using SOILDSWORKS software. ANSYS software has been used for the simulation and the numerical analysis. The rubbing conditions were simulated at speed range of 1000rpm, 1500rpm and 2000rpm. Analysis results for axial blade rubbing showed the appearance of blade passing frequency and its multiple frequencies (lx, 2x 3x etc.) and these frequencies will more excited with increasing the rotational speed. Also, it has been observed that when the rotating speed increased, the rubbing force and the harmonics frequencies in x, y and z-direction become higher and severe. The comparison study showed that axial blade rub is more dangerous and would generate a higher vibration impacts and higher blade rubbing force than radial blade rub.

  16. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220... STANDARDS) United States Standards for Grades of Peaches Definitions § 51.1220 Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light colored, or aggregates more...

  17. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220... STANDARDS) United States Standards for Grades of Peaches Definitions § 51.1220 Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light colored, or aggregates more...

  18. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220... STANDARDS) United States Standards for Grades of Peaches Definitions § 51.1220 Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light colored, or aggregates more...

  19. Comparison of hand hygiene procedures for removing Bacillus cereus spores.

    PubMed

    Sasahara, Teppei; Hayashi, Shunji; Hosoda, Kouichi; Morisawa, Yuji; Hirai, Yoshikazu

    2014-01-01

    Bacillus cereus is a spore-forming bacterium. B. cereus occasionally causes nosocomial infections, in which hand contamination with the spores plays an important role. Therefore, hand hygiene is the most important practice for controlling nosocomial B. cereus infections. This study aimed to determine the appropriate hand hygiene procedure for removing B. cereus spores. Thirty volunteers' hands were experimentally contaminated with B. cereus spores, after which they performed 6 different hand hygiene procedures. We compared the efficacy of the procedures in removing the spores from hands. The alcohol-based hand-rubbing procedures scarcely removed them. The soap washing procedures reduced the number of spores by more than 2 log10. Extending the washing time increased the spore-removing efficacy of the washing procedures. There was no significant difference in efficacy between the use of plain soap and antiseptic soap. Handwashing with soap is appropriate for removing B. cereus spores from hands. Alcohol-based hand-rubbing is not effective.

  20. Influence of rubbing on rotor dynamics, part 2

    NASA Technical Reports Server (NTRS)

    Muszynska, Agnes; Bently, Donald E.; Franklin, Wesley D.; Hayashida, Robert D.; Kingsley, Lori M.; Curry, Arthur E.

    1989-01-01

    Rotor dynamic behavior depends considerably on how much the specific physical phenomena accompanying rotor rubbing against the stator is involved. The experimental results of rotor-to-stator rubbing contact are analyzed. The computer code is described for obtaining numerical calculations of rotor-to-stator rubbing system dynamic responses. Computer generated results are provided. The reduced dynamic data from High Pressure Fuel Turbo Pump (HPFTP) hot fire test are given. The results provide some significant conclusions. Information is provided on the electronic instrumentation used in the experimental testing.

  1. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (2) made in accordance with one of the two formulas prescribed in paragraph (b) of this section, and...-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Formulas and Statements of Process General-Use Formulas § 20.118 Rubbing alcohol general-use formula. (a...

  2. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (2) made in accordance with one of the two formulas prescribed in paragraph (b) of this section, and...-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Formulas and Statements of Process General-Use Formulas § 20.118 Rubbing alcohol general-use formula. (a...

  3. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (2) made in accordance with one of the two formulas prescribed in paragraph (b) of this section, and...-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Formulas and Statements of Process General-Use Formulas § 20.118 Rubbing alcohol general-use formula. (a...

  4. Simulated Tip Rub Testing of Low-Density Metal Foam

    NASA Technical Reports Server (NTRS)

    Bowman, Cheryl L.; Jones, Michael G.

    2009-01-01

    Preliminary acoustic studies have indicated that low-density, open-cell, metal foams may be suitable acoustic liner material for noise suppression in high by-pass engines. Metal foam response under simulated tip rub conditions was studied to assess whether its durability would be sufficient for the foam to serve both as a rub strip above the rotor as well as an acoustic treatment. Samples represented four metal alloys, nominal cell dimensions ranging from 60 to 120 cells per inch (cpi), and relative densities ranging from 3.4 to 10 percent. The resulting rubbed surfaces were relatively smooth and the open cell structure of the foam was not adversely affected. Sample relative density appeared to have significant influence on the forces induced by the rub event. Acoustic responses of various surface preparations were measured using a normal incidence tube. The results of this study indicate that the foam s open-cell structure was retained after rubbing and that the acoustic absorption spectra variation was minimal.

  5. Rub al Khali, Arabia

    NASA Image and Video Library

    2008-08-08

    NASA Terra spacecraft shows the Rub al Khali, one of the largest sand deserts in the world, encompassing most of the southern third of the Arabian Peninsula; it includes parts of Oman, United Arab Emirates, and Yemen.

  6. Antimicrobial efficacy of alcohol-based hand gels.

    PubMed

    Guilhermetti, M; Marques Wiirzler, L A; Castanheira Facio, B; da Silva Furlan, M; Campo Meschial, W; Bronharo Tognim, M C; Botelho Garcia, L; Luiz Cardoso, C

    2010-03-01

    In recent years, several commercial alcohol-based hand gels have appeared on the market to improve the hand-cleansing compliance of healthcare workers. Although the antimicrobial efficacy of these products has been reported in different countries, few studies have investigated this subject in Brazil. In this study, we assessed the antimicrobial efficacy of 12 alcohol-based hand gels produced in Brazil, containing 70% w/w or v/v ethyl alcohol as the active ingredient, according to the European Standard EN 1500 (EN 1500). The following alcohol gels were tested: Hand Gel, Voga Gel, Solumax Solugel, Doctor Clean, Rio Gel, Clear Gel, Sevengel, Hand CHC, Gel Bac, WBL-50 Gel, Sanigel and Soft Care Gel. In addition, 70% w/w ethyl alcohol and three alcohol-based hand rubs (Sterillium, Sterillium Gel, and Spitaderm), commonly used in Europe and effective according to EN 1500, were also tested. All the products tested, except for two, were approved by the EN 1500 test protocol with a 60s application. The results confirmed the antimicrobial efficacy of the majority of the alcohol gels produced in Brazil for hand hygiene of healthcare workers. Copyright 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  7. Promoting hand hygiene and prudent use of antimicrobials in long-term care facilities.

    PubMed

    Rummukainen, Maija; Jakobsson, Aino; Karppi, Pertti; Kautiainen, Hannu; Lyytikäinen, Outi

    2009-03-01

    A multidisciplinary team visited all long-term care facilities (n = 123) for elderly persons in the Central Finland health care district (population, 265,000) during 2004-2005. Use of alcohol-based hand rubs and ongoing systematic antimicrobials were assessed. Thereafter, regional guidelines for prudent use of antimicrobials were published. One year after the visits, a significant increase in the mean amount of alcohol-based hand rubs used was detected while usage of antimicrobials for the prevention of urinary tract reinfections had decreased.

  8. The response of turbine engine rotors to interference rubs

    NASA Technical Reports Server (NTRS)

    Kascak, A. F.

    1980-01-01

    A method was developed for the direct integration of a rotor dynamics system experiencing a blade loss induced rotor rub. Both blade loss and rotor rub were simulated on a rotor typical of a small gas turbine. A small change in the coefficient of friction (from 0.1 to 0.2) caused the rotor to change from forward to backward whirl and to theoretically destroy itself in a few rotations. This method provides an analytical capability to study the susceptibility of rotors to rub induced backward whirl problems.

  9. Gas Chromatographic Determination of Methyl Salicylate in Rubbing Alcohol: An Experiment Employing Standard Addition.

    ERIC Educational Resources Information Center

    Van Atta, Robert E.; Van Atta, R. Lewis

    1980-01-01

    Provides a gas chromatography experiment that exercises the quantitative technique of standard addition to the analysis for a minor component, methyl salicylate, in a commercial product, "wintergreen rubbing alcohol." (CS)

  10. [Consumption of hand-hygiene products in health establishments in the west of France].

    PubMed

    Branger, B; Senechal, H; Bataillon, S; Ertzscheid, M A; Baron, R; Borgey, F; Thibon, P; Van Der Mee, N; Girard, N; Wiesel, M; Avril, C; Coulomb, F; Chaperon, J; Lejeune, B

    2005-06-01

    The study had for aim to investigate hand hygiene product use in French hospitals between 2000 and 2003. A questionnaire was sent in 2002 and 2 more in 2003 and 2004 (for 2000 to 2003) requiring data on type of hospital, number of beds, staff members, admissions and patient-day, litres of mild soap, antiseptic soap and alcohol-based rub used and price per litre. Indices were calculated accordingly. 574 hospitals answered over the 4 year period (average 143 per year) representing an average of 50 000 beds/year, 80 000 full-time staff positions, 1.2 million admissions and 16 millions patient-days. The median consumption of mild soap was 3.8 l per bed, 2.7 l per staff member, 2.4 l per 100 admissions, and 10.6 ml per patient-day. The median consumption of antiseptic soap was 1 l per bed, 0.8 l per staff member, 4.8 l per 100 admissions, and 3.2 ml per patient-day. The median consumption of alcohol-based rub (HAS) was 0.3 l per bed, 0.3 l per staff-member, 1.5 l per admission, and 0.9 l per patient-day. Between 2000 and 2003, HAS use significantly increased from 69 to 88% (a relative increase of 31%) and the median consumption increased from 0.5 ml to 1.5 ml per patient-day. 370 fully completed grids gave a number of 7 opportunities per patient-day with less than 1 for HAS. The best indicator for an infection control practitioners is the quantity of alcohol-based solution in ml/patient-day and HAS per patient-day is the reference.

  11. Field experiences with rub induced instabilities in turbomachinery

    NASA Technical Reports Server (NTRS)

    Goggin, D. G.

    1982-01-01

    Rotordynamic instability problems are not uncommon in high speed industrial turbomachinery. One type of the many destabilizing forces that can occur is caused by a rub between the stationary and rotating parts. Descriptions are given of several cases of rub induced instabilities. Included in the descriptions are the conditions at onset, the whirl frequency and direction, and the steps taken to eliminate the problem.

  12. Acoustic emissions diagnosis of rotor-stator rubs using the KS statistic

    NASA Astrophysics Data System (ADS)

    Hall, L. D.; Mba, D.

    2004-07-01

    Acoustic emission (AE) measurement at the bearings of rotating machinery has become a useful tool for diagnosing incipient fault conditions. In particular, AE can be used to detect unwanted intermittent or partial rubbing between a rotating central shaft and surrounding stationary components. This is a particular problem encountered in turbines used for power generation. For successful fault diagnosis, it is important to adopt AE signal analysis techniques capable of distinguishing between various types of rub mechanisms. It is also useful to develop techniques for inferring information such as the severity of rubbing or the type of seal material making contact on the shaft. It is proposed that modelling the cumulative distribution function of rub-induced AE signals with respect to appropriate theoretical distributions, and quantifying the goodness of fit with the Kolmogorov-Smirnov (KS) statistic, offers a suitable signal feature for diagnosis. This paper demonstrates the successful use of the KS feature for discriminating different classes of shaft-seal rubbing.

  13. The Effects of Surgical Hand Scrubbing Protocols on Skin Integrity and Surgical Site Infection Rates: A Systematic Review.

    PubMed

    Liu, Liang Qin; Mehigan, Sinead

    2016-05-01

    This systematic review aimed to critically appraise and synthesize updated evidence regarding the effect of surgical-scrub techniques on skin integrity and the incidence of surgical site infections. Databases searched include the Cumulative Index to Nursing and Allied Health Literature, MEDLINE, Embase, and Cochrane Central. Our review was limited to eight peer-reviewed, randomized controlled trials and two nonrandomized controlled trials published in English from 1990 to 2015. Comparison models included traditional hand scrubbing with chlorhexidine gluconate or povidone-iodine against alcohol-based hand rubbing, scrubbing with a brush versus without a brush, and detergent-based antiseptics alone versus antiseptics incorporating alcohol solutions. Evidence showed that hand rubbing techniques are as effective as traditional scrubbing and seem to be better tolerated. Hand rubbing appears to cause less skin damage than traditional scrub protocols, and scrub personnel tolerated brushless techniques better than scrubbing using a brush. Copyright © 2016 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  14. Behaviour modification in the management of chronic habits of abnormal eye rubbing.

    PubMed

    McMonnies, Charles W

    2009-04-01

    To describe how and why many keratoconus patients do not comply with strong advice to control chronic habits of abnormal rubbing. To outline a behaviour modification approach for controlling chronic habits of abnormal rubbing. Common reasons for chronic habits of abnormal rubbing have been reviewed as a basis for specifying a behavioural modification approach to habit reversal. The methods described are organized into the classic behavioural modification structure of: (1) habit awareness, (2) competing responses, (3) development of motivation, and (4) social support. This structure is supported by the application of social influence principles to achieve optimum compliance. The use of take-home written information in the form of an Abnormal Rubbing Guide is the basis for the development of motivation. Family social support is based upon a widening of the responsibility for avoiding eye rubbing to all family members. Some patients will need minimal application of these principles with patient education being sufficient intervention to achieve habit reversal. For patients with strong provocation to rubbing and/or by having a well established rubbing habit, a greater exposure to the habit reversal program described is indicated. Successful habit reversal may slow the rate of ectasia progression. Prophylactic application of the methods described for patients who are at risk for developing keratoconus, or post-laser assisted in situ keratomileusis keratectasia, may show that some forms of keratectasia are preventable.

  15. Multicenter intervention program to increase adherence to hand hygiene recommendations and glove use and to reduce the incidence of antimicrobial resistance.

    PubMed

    Trick, William E; Vernon, Michael O; Welbel, Sharon F; Demarais, Patricia; Hayden, Mary K; Weinstein, Robert A

    2007-01-01

    To determine whether a multimodal intervention could improve adherence to hand hygiene and glove use recommendations and decrease the incidence of antimicrobial resistance in different types of healthcare facilities. Prospective, observational study performed from October 1, 1999, through December 31, 2002. We monitored adherence to hand hygiene and glove use recommendations and the incidence of antimicrobial-resistant bacteria among isolates from clinical cultures. We evaluated trends in and predictors for adherence and preferential use of alcohol-based hand rubs, using multivariable analyses. Three intervention hospitals (a 660-bed acute and long-term care hospital, a 120-bed community hospital, and a 600-bed public teaching hospital) and a control hospital (a 700-bed university teaching hospital).Intervention. At the intervention hospitals, we introduced or increased the availability of alcohol-based hand rub, initiated an interactive education program, and developed a poster campaign; at the control hospital, we only increased the availability of alcohol-based hand rub. We observed 6,948 hand hygiene opportunities. The frequency of hand hygiene performance or glove use significantly increased during the study period at the intervention hospitals but not at the control hospital; the maximum quarterly frequency of hand hygiene performance or glove use at intervention hospitals (74%, 80%, and 77%) was higher than that at the control hospital (59%). By multivariable analysis, preferential use of alcohol-based hand rubs rather than soap and water for hand hygiene was more likely among workers at intervention hospitals compared with nonintervention hospitals (adjusted odds ratio, 4.6 [95% confidence interval, 3.3-6.4]) and more likely among physicians (adjusted odds ratio, 1.4 [95% confidence interval, 1.2-1.8]) than among nurses at intervention hospitals. A significantly reduced incidence of antimicrobial-resistant bacteria among isolates from clinical culture was

  16. The Snowball Blizzard Incident: A Reality Rub Life Space Interview.

    ERIC Educational Resources Information Center

    Long, Nicholas J.; Pinciotti, Dennis

    1992-01-01

    Focuses on Reality Rub Interview, one type of Life Space Interview (LSI), effective intervention strategy for use during crisis work with troubled students. Presents actual Reality Rub Interview, used with students who have "social blindness, social myopia, and tunnel vision" and who, when upset, misinterpret words and behaviors of…

  17. The Role of RUB (related to ubiquitin) Family of Proteins in the Hormone Response. Final Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Callis, Judy

    2013-03-22

    The Rub pathway is a conserved protein modification pathway. RUB (called Rubp1 in budding yeast, Nedd8 in animals and RUB in plants) is a ubiquitin-like 76-amino acid protein. It covalently attaches to protein using an enzymatic machinery analogous to the enzymes that attach ubiquitin to its substrate proteins. However, the nature of the complement of Rub-modified proteins in organisms was not clear. From bioinformatics analyses, one can identify a Rub activating enzymes and Rub conjugating enzymes. However, in many cases, their biochemical properties were not described. In DOE-funded work, we made major advances in our understanding of the Rub pathwaymore » in yeast and plants, work that is applicable to other organisms as well. There is a multi-subunit enzyme called SCF in all eukaryotes. The SCF consists of several subunits that serve as a scaffold (the cullin, SKP and RBX subunits) and one subunit that interacts with the substrate. This cullin protein (called Cdc53p in yeast and CULLIN 1 in plants and animals) was a known Rub target. In this work, we identified additional Rub targets in yeast as the other cullin-like proteins Cul3p and Rtt101p. Additionally we described the conservation of the Rub pathway because plant RUB1 can conjugated to yeast Cdc53p- in yeast. In the model plant Arabidopsis thaliana, we characterized the Rub activating enzymes and showed that they are not biochemically equivalent. We also showed that the Rub pathway is essential in plants and characterized plants with reduced levels of rub proteins. These plants are affected in multiple developmental processes. We discovered that they over-produce ethylene as dark-grown seedlings. We characterized a mutant allele of CULLIN1 in Arabidopsis with impaired interaction with RBX and showed that it is unstable in vivo. We used our knowledge of monitoring protein degradation to map the degradation determinants in a plant transcription factor. Finally, we took a mass spectrometric approach to

  18. Hand Hygiene Practices Among Indian Medical Undergraduates: A Questionnaire-Based Survey

    PubMed Central

    Modi, Pranav D; Solanki, Rajavi; Modi, Janhavi; Chandramani, Srinath; Gill, Niharika

    2017-01-01

    Background and objectives To prevent the spread of infections in all healthcare settings, hand hygiene must be routinely practiced. Appropriate hand hygiene techniques can go a long way in reducing nosocomial infections, cross-transmission of microorganisms and the risk of occupational exposure to infectious diseases. World Health Organisation (WHO) has taken an incredible approach called “My Five Moments for Hand Hygiene" which defines the key moments when health-care workers should perform hand hygiene. We thus carried out a survey to assess knowledge of hand hygiene practices among undergraduate medical students.  Materials and methods A cross-sectional survey was conducted among 523 Indian medical undergraduates. The questionnaire used was adapted from the WHO hand hygiene knowledge questionnaire for health-care workers and was distributed both, in print and online formats. The response to each question was examined using percentages. Results Nearly 57% (n=298) of medical students who participated in this study did not receive any formal training in hand hygiene. Only 27% (n=141) students knew that the most frequent source of germs responsible for health-care associated infections were the germs already present on or within the patient. Nearly 68.6% (n= 359) students were unaware of the sequence of hand washing and hand rubbing. Although 71.9% (n=376 ) students claimed that they use an alcohol-based hand rub routinely, only 36.1% (n=189 ) students knew the time required for a hand rub to kill the germs on the hands. Overall hand hygiene knowledge was low in 6.9% (n=36), moderate in 80.9% (n=423) and good in 12.2% (n=23) of respondents.  Conclusions The awareness about hand hygiene practices among medical students is low. Nearly 57% (n=298) of the respondents never received any formal training in hand hygiene throughout their course of medical undergraduate study. To prevent the spread of infections in healthcare settings, medical students should be given

  19. Degraded Chinese rubbing images thresholding based on local first-order statistics

    NASA Astrophysics Data System (ADS)

    Wang, Fang; Hou, Ling-Ying; Huang, Han

    2017-06-01

    It is a necessary step for Chinese character segmentation from degraded document images in Optical Character Recognizer (OCR); however, it is challenging due to various kinds of noising in such an image. In this paper, we present three local first-order statistics method that had been adaptive thresholding for segmenting text and non-text of Chinese rubbing image. Both visual inspection and numerically investigate for the segmentation results of rubbing image had been obtained. In experiments, it obtained better results than classical techniques in the binarization of real Chinese rubbing image and PHIBD 2012 datasets.

  20. Rotor vibration caused by external excitation and rub

    NASA Technical Reports Server (NTRS)

    Matsushita, O.; Takagi, M.; Kikuchi, K.; Kaga, M.

    1982-01-01

    For turbomachinery with low natural frequencies, considerations have been recently required for rotor vibrations caused by external forces except unbalance one, such as foundation motion, seismic wave, rub and so forth. Such a forced vibration is investigated analytically and experimentally in the present paper. Vibrations in a rotor-bearing system under a harmonic excitation are analyzed by the modal technique in the case of a linear system including gyroscopic effect. For a nonlinear system a new and powerful quasi-modal technique is developed and applied to the vibration caused by rub.

  1. Hand hygiene: product preference and compliance.

    PubMed

    Tanner, Judith; Mistry, Neetesh

    Hospitals are trying to improve patient hand hygiene by providing handwashing products at the bedside. Patients' compliance with handwashing depends on their satisfaction with hygiene products but no one has looked at which products patients prefer. Research on this will help hospitals target hand hygiene more appropriately and effectively. To explore patient satisfaction with hand hygiene products and identify those that are most popular. Two hundred patients were given five hand hygiene products to evaluate. These represent the interventions most widely used by patients in hospitals: alcohol foams, alcohol wipes, wet cloths with antiseptic solutions, bowls of soapy water and mobile sinks. Alcohol foam achieved the highest mean satisfaction score and was significantly more popular than the other products. Alcohol foam was the most popular choice regardless of age, sex, dexterity, mobility and religion.

  2. Combined use of alcohol hand rub and gloves reduces the incidence of late onset infection in very low birthweight infants.

    PubMed

    Ng, P C; Wong, H L; Lyon, D J; So, K W; Liu, F; Lam, R K Y; Wong, E; Cheng, A F B; Fok, T F

    2004-07-01

    To assess the incidence of late onset (> 72 hours) infection and necrotising enterocolitis (NEC) in very low birthweight (VLBW) infants in two 36 month periods using two hand hygiene protocols: conventional handwashing (HW; first 36 month period); an alcohol hand rub and gloves technique (HR; second 36 month period). VLBW infants admitted to the neonatal intensive care unit during the period December 1993-November 1999 were eligible. A new hand hygiene protocol using alcohol handrub and gloves was introduced in December 1996. Each patient's case record was reviewed retrospectively by two independent investigators using a standard data collection form. The incidence of NEC and systemic infections, including bacterial or fungal septicaemia, meningitis, and peritonitis, in the two periods were compared. The HW and HR groups contained 161 and 176 VLBW infants respectively. The incidence of late onset systemic infection decreased from 13.5 to 4.8 episodes (including NEC)/1000 patient days after introduction of the HR regimen, representing a 2.8-fold reduction. Similarly, the incidence of Gram positive, Gram negative, and fungal infections decreased 2.5-fold, 2.6-fold, and 7-fold respectively. There was also a significant reduction in the incidence of NEC in the HR group (p < 0.0001). Subgroup analysis revealed that the incidence of methicillin resistant Staphylococcus aureus (MRSA) septicaemia was significantly decreased in the second 36 month period (p = 0.048). The clinical data suggest that infants in the HW group had significantly earlier onset of sepsis (p < 0.05) and required oxygen supplementation for longer (p < 0.05) than those in the HR group. Significantly more VLBW infants were discharged from the neonatal intensive care unit without ever being infected (p < 0.0001), and also significantly fewer infants had more than one episode of infection in the HR group (p < 0.0001). The introduction of the HR protocol was associated with a 2.8-fold reduction in the

  3. Rub tolerant shroud

    NASA Technical Reports Server (NTRS)

    Lenahan, Dean T. (Inventor); Gay, Jr., Charles H. (Inventor)

    1985-01-01

    A seal structure between first and second relatively moveable members for preventing gas flow in the space between the members and transverse to their general direction of motion is disclosed. The seal structure includes a plurality of substantially parallel strips within 30.degree. of normal to the radial plane generally containing these first and second relatively moveable members. The strips are thin and closely spaced and arranged so that one strip edge is attached to the first member and another edge is free to resiliently deflect when in rubbing contact with the second member.

  4. Hand hygiene in rural Indonesian healthcare workers: barriers beyond sinks, hand rubs and in-service training.

    PubMed

    Marjadi, B; McLaws, M-L

    2010-11-01

    Few attempts to increase healthcare workers' hand hygiene compliance have included an in-depth analysis of the social and behavioural context in which hand hygiene is not undertaken. We used a mixed method approach to explore hand hygiene barriers in rural Indonesian healthcare facilities to develop a resource-appropriate adoption of international guidelines. Two hospitals and eight clinics (private and public) in a rural Indonesian district were studied for three months each. Hand hygiene compliance was covertly observed for two shifts each in three adult wards at two hospitals. Qualitative data were collected from direct observation, focus group discussions and semistructured in-depth and informal interviews within healthcare facilities and the community. Major barriers to compliance included longstanding water scarcity, tolerance of dirtiness by the community and the healthcare organisational culture. Hand hygiene compliance was poor (20%; 57/281; 95% CI: 16-25%) and was more likely to be undertaken after patient contact (34% after-patient contact vs 5% before-patient contact, P<0.001) and 'inherent' opportunities associated with contacts perceived to be dirty (49% 'inherent' vs 11% 'elective' opportunities associated with clean contacts, P<0.001). Clinicians frequently touched patients without hand hygiene, and some clinicians avoided touching patients altogether. The provision of clean soap and water and in-service training will not overcome strong social and behavioural barriers unless interventions focus on long term community education and managerial commitment to the provision of supportive working conditions. Copyright © 2010 The Hospital Infection Society. All rights reserved.

  5. Effect of eye rubbing on signs and symptoms of allergic conjunctivitis in cat-sensitive individuals.

    PubMed

    Raizman, M B; Rothman, J S; Maroun, F; Rand, W M

    2000-12-01

    To evaluate the effect of eye rubbing on signs and symptoms of allergic conjunctivitis in cat-sensitive individuals. Two prospective, nonrandomized comparative studies. Thirteen patients in the first study and 20 patients in the second study with a documented history of acute allergic conjunctivitis induced by exposure to cats were enrolled. In the first trial, all patients had one eye rubbed 15 times by the investigator without exposure to airborne allergens. Both eyes were evaluated after 5, 15, 30, and 60 minutes using subject questionnaires and slit-lamp examination. At least 1 week later, each patient was exposed to cat dander for 75 minutes; 15 minutes after entering the cat room, each patient had one eye rubbed 15 times by the examiner. Subjects' eyes were then evaluated using questionnaires and slit-lamp examination. In the second trial, the visits were identical to the first trial, except that the rubbed eye in each visit was rubbed 20 times and with more force, and that patients wore masks during exposure to cat dander. In both studies, the difference between patients' rubbed and nonrubbed eyes with respect to ocular itching, chemosis, and hyperemia was noted 5, 15, 30, and 60 minutes after controlled eye rubbing. Without exposure to the cat room, rubbed eyes exhibited increased itching at 5 minutes in both studies and at 15 minutes in the second study (P < 0.05), increased chemosis at 5 and 15 minutes in the second study (P < 0.05), and increased hyperemia at 5 minutes in the second study (P < 0.05) compared with nonrubbed eyes. During exposure to cat dander, rubbed eyes consistently exhibited increased itching at 5, 15, and 30 minutes in the first and second study as well as at 60 minutes in the second study compared with nonrubbed eyes. Furthermore, during exposure to cat dander, rubbed eyes consistently exhibited increased chemosis at 5 and 15 minutes (P < 0.05) and increased hyperemia at 5, 15, and 30 minutes (P < 0.05) in the second study compared

  6. Light and short arc rubs in rotating machines: Experimental tests and modelling

    NASA Astrophysics Data System (ADS)

    Pennacchi, P.; Bachschmid, N.; Tanzi, E.

    2009-10-01

    Rotor-to-stator rub is a non-linear phenomenon which has been analyzed many times in rotordynamics literature, but very often these studies are devoted simply to highlight non-linearities, using very simple rotors, rather than to present reliable models. However, rotor-to-stator rub is actually one of the most common faults during the operation of rotating machinery. The frequency of its occurrence is increasing due to the trend of reducing the radial clearance between the seal and the rotor in modern turbine units, pumps and compressors in order to increase efficiency. Often the rub occurs between rotor and seals and the analysis of the phenomenon cannot set aside the consideration of the different relative stiffness. This paper presents some experimental results obtained by means of a test rig in which rub conditions of real machines are reproduced. In particular short arc rubs are considered and the shaft is stiffer than the obstacle. Then a model, suitable to be employed for real rotating machinery, is presented and the simulations obtained are compared with the experimental results. The model is able to reproduce the behaviour of the test rig.

  7. Improving hand hygiene in a paediatric hospital: a multimodal quality improvement approach.

    PubMed

    Jamal, Ahmed; O'Grady, G; Harnett, E; Dalton, D; Andresen, D

    2012-02-01

    Effective hand hygiene has long been recognised as an important way to reduce the transmission of bacterial and viral pathogens in healthcare settings. However, many studies have shown that adherence to hand hygiene remains low, and improvement efforts have often not delivered sustainable results. The Children's Hospital at Westmead is the largest tertiary paediatric hospital in Sydney, Australia. The hospital participated in a state-wide 'Clean hands save lives' campaign which was initiated in 2006. Strong leadership, good stakeholder engagement, readily accessible alcohol-based hand rub at the point of patient care, a multifaceted education programme, monitoring of staff, adherence to recommended hand hygiene practices and contemporaneous feedback of performance data have significantly improved and maintained compliance with hand hygiene. Hand hygiene compliance has increased from 23% in 2006 to 87% in 2011 (p<0.001). Sustained improvement in compliance with hand hygiene has been evident in the last 4 years. A decline in a set of hospital-acquired infections (including rotavirus, multiresistant organism transmission, and nosocomial bacteraemia) has also been noted as hand hygiene rates have improved. Monthly usage of alcohol-based hand rub has increased from 16 litres/1000 bed days to 51 litres/1000 bed days during this same period. This project has delivered sustained improvement in hand hygiene compliance by establishing a framework of multimodal evidence-based strategies.

  8. Three years of national hand hygiene campaign in Germany: what are the key conclusions for clinical practice?

    PubMed

    Reichardt, C; Königer, D; Bunte-Schönberger, K; van der Linden, P; Mönch, N; Schwab, F; Behnke, M; Gastmeier, P

    2013-02-01

    The World Health Organization (WHO) started the 'Clean Care is Safer Care' campaign in 2005. Since then, more than 120 countries have pledged to improve hand hygiene as a keystone of their national or subnational healthcare-associated infection prevention programmes. Thirty-eight countries have implemented national campaigns. Germany started a national campaign to improve hand hygiene compliance on 1 January 2008. The campaign, 'AKTION Saubere Hände', is funded by the German Ministry of Health and was initiated by the National Reference Centre for the Surveillance of Nosocomial Infections, the Society for Quality Management in Health Care and the German Coalition for Patient Safety. The campaign is designed as a multi-modal campaign based on the WHO implementation strategy. Since the end of 2010, more than 700 healthcare institutions have been actively participating in the campaign, among which are 28 university hospitals. Voluntarily participating hospitals have to implement the following measures: active support by hospital administrators of local campaign implementation, participation in a one-day introductory course, education of healthcare workers at least once a year, measurement of alcohol-based hand-rub consumption (AHC) and feedback on resulting data, implementation of the WHO 'My Five Moments for Hand Hygiene' model, increase in hand-rub availability, participation in national hand hygiene day at least every two years, and participation in national campaign network workshops at least once every two years. Observational studies to measure hand hygiene compliance are optional. Overall, there has been a significant increase of 11% in hand hygiene compliance in 62 hospitals that observed compliance before and after intervention. A total of 129 hospitals provided AHC data for three years and achieved an overall increase of 30.7%. The availability of alcohol-based hand rub increased from 86.8% to > 100% in intensive care units and from 63.6% to 91.3% in non

  9. Effect of rubbing on the in vitro skin permeation of diclofenac-diethylamine 1.16% gel.

    PubMed

    Hasler-Nguyen, Nathalie; Fotopoulos, Grigorios

    2012-06-21

    Rubbing a topical NSAID (non steroidal anti-inflammatory drug) on the skin may increase local drug permeation, affecting its distribution to the site of pain and inflammation. The present study evaluates this hypothesis, by assessing in vitro the effect on skin permeation of applying diclofenac-dieythylamine 1.16% gel with or without rubbing. A single dose of 5 mg/cm2 diclofenac-diethylamine 1.16% gel was applied on excised human skin mounted in Franz-type diffusion cells without or with rubbing for 45 s. Drug penetration into the skin layers was determined after 1 h using the tape stripping technique. In vitro cutaneous permeation into the receptor fluid of the diffusion chamber was measured up to 24 h. Skin electrical resistance was also recorded. Application of diclofenac-diethylamine 1.16% gel with rubbing resulted to a 5-fold higher flux of diclofenac through the skin than when applied without rubbing at 8 h (P = 0.04). Skin rubbing for 45 s decreased by 2-fold skin electrical resistance when compared to the standard application. Application of diclofenac-diethylamine 1.16% gel with rubbing tended to result in higher accumulation in the stripped skin vs. the superficial skin layers when applied without rubbing (P = 0.2). These results suggest that rubbing may alter the superficial skin layer resulting in a transient faster initial diffusion of topically applied diclofenac through the stratum corneum into the deeper skin layer of the dermis to the tissue target.

  10. Effect of rubbing on the in vitro skin permeation of diclofenac-diethylamine 1.16% gel

    PubMed Central

    2012-01-01

    Background Rubbing a topical NSAID (non steroidal anti-inflammatory drug) on the skin may increase local drug permeation, affecting its distribution to the site of pain and inflammation. The present study evaluates this hypothesis, by assessing in vitro the effect on skin permeation of applying diclofenac-dieythylamine 1.16% gel with or without rubbing. Methods A single dose of 5 mg/cm2 diclofenac-diethylamine 1.16% gel was applied on excised human skin mounted in Franz-type diffusion cells without or with rubbing for 45 s. Drug penetration into the skin layers was determined after 1 h using the tape stripping technique. In vitro cutaneous permeation into the receptor fluid of the diffusion chamber was measured up to 24 h. Skin electrical resistance was also recorded. Results Application of diclofenac-diethylamine 1.16% gel with rubbing resulted to a 5-fold higher flux of diclofenac through the skin than when applied without rubbing at 8 h (P = 0.04). Skin rubbing for 45 s decreased by 2-fold skin electrical resistance when compared to the standard application. Application of diclofenac-diethylamine 1.16% gel with rubbing tended to result in higher accumulation in the stripped skin vs. the superficial skin layers when applied without rubbing (P = 0.2). Conclusion These results suggest that rubbing may alter the superficial skin layer resulting in a transient faster initial diffusion of topically applied diclofenac through the stratum corneum into the deeper skin layer of the dermis to the tissue target. PMID:22720797

  11. Hand hygiene in the nursery during diaper changing.

    PubMed

    Phang, Koh Ni; Maznin, Nur Liyanna; Yip, Wai Kin

    2012-12-01

    This project aimed to improve hand hygiene practice during diaper changing among nurses working in the nursery. This project was conducted in one of the nurseries in a 935-bed acute care hospital with a sample of 15 nurses. A pre- and post-intervention audit was conducted utilising the Joanna Briggs Institute Practical Application of Clinical Evidence System and Getting Research into Practice module. A revised written workflow, which specified the occasions and process for hand hygiene during diaper changing, was introduced. Modifications to the baby bassinets and nursery were made after barriers to good hand hygiene were identified. The project was carried out over 4 months, from March to June 2011. The post-intervention audit results show an improvement in performing hand washing after changing diapers (20%) and performing the correct steps of hand rubbing (25%). However, the compliance rates decreased for the other criteria that measured whether hand rubbing or hand washing was performed prior to contacting the infant and after wrapping the infant, and whether hand washing was performed correctly. The improvement in compliance with hand washing--the main focus of the new workflow--after changing diapers was especially significant. The results indicated that having a workflow on the occasions and process for hand hygiene during diaper changing was useful in standardising practice. Pre- and post-implementation audits were effective methods for evaluating the effect of translating evidence into practice. However, this project had limited success in improving compliance with hand hygiene. This suggested that more effort is needed to reinforce the importance of hand hygiene and compliance to the proposed workflow. In addition, this project showed that for change to take place successfully, environmental modifications, increased awareness and adequate communication to every staff member are essential. © 2012 The Authors. International Journal of Evidence

  12. A recessive mutation in the RUB1-conjugating enzyme, RCE1, reveals a requirement for RUB modification for control of ethylene biosynthesis and proper induction of basic chitinase and PDF1.2 in Arabidopsis.

    PubMed

    Larsen, Paul B; Cancel, Jesse D

    2004-05-01

    By screening etiolated Arabidopsis seedlings for mutants with aberrant ethylene-related phenotypes, we identified a mutant that displays features of the ethylene-mediated triple response even in the absence of ethylene. Further characterization showed that the phenotype observed for the dark-grown seedlings of this mutant is reversible by prevention of ethylene perception and is dependent on a modest increase in ethylene production correlated with an increase in 1-aminocyclopropane-1-carboxylic acid (ACC) oxidase (ACO) activity in the hypocotyl. Molecular characterization of leaves of the mutant revealed severely impaired induction of basic chitinase (chiB) and plant defensin (PDF)1.2 following treatment with jasmonic acid and/or ethylene. Positional cloning of the mutation resulted in identification of a 49-bp deletion in RCE1 (related to ubiquitin 1 (RUB1)-conjugating enzyme), which has been demonstrated to be responsible for covalent attachment of RUB1 to the SCF (Skpl Cdc 53 F-box) ubiquitin ligase complex to modify its activity. Our analyses with rce1-2 demonstrate a previously unknown requirement for RUB1 modification for regulation of ethylene biosynthesis and proper induction of defense-related genes in Arabidopsis.

  13. In vitro-in vivo sequence studies as a method of selecting the most efficacious alcohol-based solution for hygienic hand disinfection.

    PubMed

    Herruzo, R; Vizcaino, M J; Herruzo, I

    2010-05-01

    The use of alcohol-based hand rubs serves to reduce hospital-acquired infections. Many products of this type are now on offer and it is essential to know how to rank their efficacy. A sequence of tests is proposed here to compare any given new alcohol-based solution against the reference solution (60% 2-isopropyl-alcohol) with 30 s of contact time: (i) in vitro (with pig skin as carrier) testing of >30 species of microorganism; (ii) in vitro assessment of residual efficacy (after 30 min of drying); (iii) in vivo study of transient microbiota (modification of the EN 1500 standard procedure) using four ATCC strains; (iv) in vivo study of resident hand microbiota. After performing the in vitro evaluation of seven alcohol-based hand rubs, the two most efficacious (chlorhexidine-quac-alcohol and mecetronium- alcohol) were chosen and studied, comparatively with the reference solution (60% isopropyl alcohol), in vitro (for chemical sustainability on the skin) and in vivo (against transient and resident microbiota). Chlorhexidine-quac-alcohol proved to be significantly superior to mecetronium-alcohol or the reference solution in all tests, except against resident microbiota for which the improvement was not statistically significant.

  14. Effects of geometric variables on rub characteristics of Ti-6Al-4V

    NASA Technical Reports Server (NTRS)

    Bill, R. C.; Wolak, J.; Wisander, D. W.

    1981-01-01

    Experiments simulating rub interactions between Ti-6Al-4V blade tips and various seal materials were conducted. The number of blade tips and the blade tip geometry were varied to determine their effects on rub forces and on wear phenomena. Contact was found to be quite unsteady for all blade tip geometries except for those incorporating deliberately rounded blade tips. The unsteady contact was characterized by long periods of rubbing contact and increasing blade tip that terminated in sudden rapid metal removal, sometimes accompanied by tearing and disruption of porous seal material under the rub surface. A model describing the blade tip loading is proposed and is based on the propagation of an elastic stress wave through the seal material as the seal material is dynamically compressed by the blade tip leading edge.

  15. Rotor-to-stator Partial Rubbing and Its Effects on Rotor Dynamic Response

    NASA Technical Reports Server (NTRS)

    Muszynska, Agnes; Franklin, Wesley D.; Hayashida, Robert D.

    1991-01-01

    Results from experimental and analytical studies on rotor to stationary element partial rubbings at several locations and their effects on rotor dynamic responses are presented. The mathematical model of a rubbing rotor is given. The computer program provides numerical results which agree with experimentally obtained rotor responses.

  16. Factors associated with hand hygiene practices in two neonatal intensive care units.

    PubMed

    Cohen, Bevin; Saiman, Lisa; Cimiotti, Jeannie; Larson, Elaine

    2003-06-01

    To determine whether hand hygiene practices differ between levels of contact with neonates; to characterize the hand hygiene practices of different types of personnel; and to compare hand hygiene practices in neonatal intensive care units (NICUs) using different products. Research assistants observed staff hand hygiene practices during 38 sessions in two NICUs. Patient touches were categorized as touching within the neonates' environment but only outside the Isolette (Level 1), touching within the Isolette but not the neonate directly (Level 2) or directly touching the neonate (Level 3). Hand hygiene practices for each touch were categorized into five groups: cleaned hands and new gloves; uncleaned hands and new gloves; used gloves; clean hands and no gloves; uncleaned hands and no gloves. Research assistants observed 1472 touches. On average each neonate or his or her immediate environment was touched 78 times per shift. Nurses (P = 0.001), attending physicians (P = 0.02) and physicians-in-training (P = 0.03) were more likely to use appropriate practices during Level 3 touches, but only 22.8% of all touches were with cleaned and/or newly gloved hands. The mean number of direct touches by staff members with cleaned hands was greater in the NICU using an alcohol-based hand rub than in the NICU using antimicrobial soap (P < 0.01). Hand hygiene was suboptimal in this high risk setting; administrative action and improved products may be needed to assure acceptable practice. In this study use of an alcohol-based product was associated with significantly improved hand hygiene and should be encouraged, as recommended in the new CDC hand hygiene guideline.

  17. Comparison of the antibacterial efficacy and acceptability of an alcohol-based hand rinse with two alcohol-based hand gels during routine patient care.

    PubMed

    Barbut, Frédéric; Maury, Eric; Goldwirt, Laurianne; Boëlle, Piérre-Yves; Neyme, Denis; Aman, Rubina; Rossi, Beatrice; Offenstadt, Georges

    2007-06-01

    The aims of this study were to compare the antibacterial efficacy of handrubbing with an alcoholic rinse (AHRR) and two different alcoholic gels (AHRG) in reducing hand contamination under practical use conditions. We wanted to assess the acceptability of the three products and to determine the effect of each product on overall hand hygiene compliance. A prospective alternating time-series clinical trial was performed in a medical intensive care unit. The study was divided into three six-week periods (P1, P2, P3). Handrubbing was achieved with Sterillium rinse (AHRR) during P1, sterillium gel(AHRG-1) during P2 and Manugel Plus (AHRG-2) during P3. Pre- and post-rubbing hand contaminations were assessed immediately after a direct contact with a patient, using the glove juice technique. Health care workers (HCWs) evaluated the acceptability of the products through a self-administered anonymous questionnaire. Compliance of HCWs with hand hygiene was assessed during the three periods. We studied 242 handrubbing opportunities. The mean reduction factor (expressed as the Log(10) CFU/mL) of the AHRR, AHRG-1 and AHRG-2 were 1.28+/-0.95, 1.29+/-0.84 and 0.51+/-0.73, respectively (p<0.001). Assessment of the three products by HCWs indicated that AHRR and AHRG-1 were significantly better accepted than AHRG-2. The overall compliance of HCWs to hand hygiene was better when gel was available. Under practical use conditions, AHRG-1 and AHRR were more effective than AHRG-2, although all were claimed to pass the European standard EN1500. In vivo trials are essential to compare the antimicrobial efficacy of products for handrubbing.

  18. Skin reactions related to hand hygiene and selection of hand hygiene products.

    PubMed

    Larson, Elaine; Girard, Raphaelle; Pessoa-Silva, Carmem Lucia; Boyce, John; Donaldson, Liam; Pittet, Didier

    2006-12-01

    In October 2004, The World Health Organization (WHO) launched the World Alliance for Patient Safety. Within the alliance, the first priority of the Global Patient Safety Challenge is to reduce health care-associated infection. A key action within the challenge is to promote hand hygiene in health care globally as well as at the country level through the campaign "Clean Care is Safer Care." As a result, the WHO is developing Guidelines on Hand Hygiene in Health Care, designed to be applicable throughout the world. This paper summarizes one component of the global WHO guidelines related to the impact of hand hygiene on the skin of health care personnel, including a discussion of types of skin reactions associated with hand hygiene, methods to reduce adverse reactions, and factors to consider when selecting hand hygiene products. Health care professionals have a higher prevalence of skin irritation than seen in the general population because of the necessity for frequent hand hygiene during patient care. Ways to minimize adverse effects of hand hygiene include selecting less irritating products, using skin moisturizers, and modifying certain hand hygiene practices such as unnecessary washing. Institutions need to consider several factors when selecting hand hygiene products: dermal tolerance and aesthetic preferences of users as well as practical considerations such as convenience, storage, and costs.

  19. Hand hygiene regimens for the reduction of risk in food service environments.

    PubMed

    Edmonds, Sarah L; McCormack, Robert R; Zhou, Sifang Steve; Macinga, David R; Fricker, Christopher M

    2012-07-01

    Pathogenic strains of Escherichia coli and human norovirus are the main etiologic agents of foodborne illness resulting from inadequate hand hygiene practices by food service workers. This study was conducted to evaluate the antibacterial and antiviral efficacy of various hand hygiene product regimens under different soil conditions representative of those in food service settings and assess the impact of product formulation on this efficacy. On hands contaminated with chicken broth containing E. coli, representing a moderate soil load, a regimen combining an antimicrobial hand washing product with a 70% ethanol advanced formula (EtOH AF) gel achieved a 5.22-log reduction, whereas a nonantimicrobial hand washing product alone achieved a 3.10log reduction. When hands were heavily soiled from handling ground beef containing E. coli, a wash-sanitize regimen with a 0.5% chloroxylenol antimicrobial hand washing product and the 70% EtOH AF gel achieved a 4.60-log reduction, whereas a wash-sanitize regimen with a 62% EtOH foam achieved a 4.11-log reduction. Sanitizing with the 70% EtOH AF gel alone was more effective than hand washing with a nonantimicrobial product for reducing murine norovirus (MNV), a surrogate for human norovirus, with 2.60- and 1.79-log reductions, respectively. When combined with hand washing, the 70% EtOH AF gel produced a 3.19-log reduction against MNV. A regimen using the SaniTwice protocol with the 70% EtOH AF gel produced a 4.04-log reduction against MNV. These data suggest that although the process of hand washing helped to remove pathogens from the hands, use of a wash-sanitize regimen was even more effective for reducing organisms. Use of a high-efficacy sanitizer as part of a wash-sanitize regimen further increased the efficacy of the regimen. The use of a well-formulated alcohol-based hand rub as part of a wash-sanitize regimen should be considered as a means to reduce risk of infection transmission in food service facilities.

  20. An experimental investigation of rubbing interaction in labyrinth seals at cryogenic temperature

    NASA Technical Reports Server (NTRS)

    Dolan, F. X.; Kennedy, F. E.; Schulson, E. M.

    1985-01-01

    An experimental program was carried out to address issues related to the observed cracking of the titanium knife edges on the labyrinth seals of the high pressure fuel pump (HPFP) in the Space Shuttle main engine (SSME). Thermal shock experiments were carried out using a jet specimen with geometry similar to the knife edge geometry. These tests demonstrate that cracking of the titanium alloy is possible in a situation involving repeated thermal cycles over a wide temperature range, as might be realized during a rub in the liquid hydrogen fuel pump. High speed rub interaction tests were conducted using a representative knife edge and seal geometry over a broad range of interaction rates. Alternative materials were also experimentally evaluated. These tests provide information which can be used to design improved labyrinth seals for the HPFP of the SSME. In particular, plasma-sprayed aluminum-graphite was found to be significantly better than aluminum alloy seals used at present from the standpoint of rub performance. Ion nitriding of the titanium alloy knife edges was also found to improve rub performance compared with the untreated baseline knife edge material.

  1. Rubbing time and bonding performance of one-step adhesives to primary enamel and dentin.

    PubMed

    Botelho, Maria Paula Jacobucci; Isolan, Cristina Pereira; Schwantz, Júlia Kaster; Lopes, Murilo Baena; Moraes, Rafael Ratto de

    2017-01-01

    This study investigated whether increasing the concentration of acidic monomers in one-step adhesives would allow reducing their application time without interfering with the bonding ability to primary enamel and dentin. Experimental one-step self-etch adhesives were formulated with 5 wt% (AD5), 20 wt% (AD20), or 35 wt% (AD35) acidic monomer. The adhesives were applied using rubbing motion for 5, 10, or 20 s. Bond strengths to primary enamel and dentin were tested under shear stress. A commercial etch-and-rinse adhesive (Single Bond 2; 3M ESPE) served as reference. Scanning electron microscopy was used to observe the morphology of bonded interfaces. Data were analysed at p<0.05. In enamel, AD35 had higher bond strength when rubbed for at least 10 s, while application for 5 s generated lower bond strength. In dentin, increased acidic monomer improved bonding only for 20 s rubbing time. The etch-and-rinse adhesive yielded higher bond strength to enamel and similar bonding to dentin as compared with the self-etch adhesives. The adhesive layer was thicker and more irregular for the etch-and-rinse material, with no appreciable differences among the self-etch systems. Overall, increasing the acidic monomer concentration only led to an increase in bond strength to enamel when the rubbing time was at least 10 s. In dentin, despite the increase in bond strength with longer rubbing times, the results favoured the experimental adhesives compared to the conventional adhesive. Reduced rubbing time of self-etch adhesives should be avoided in the clinical setup.

  2. Analysis of alcohol-based hand sanitizer delivery systems: efficacy of foam, gel, and wipes against influenza A (H1N1) virus on hands.

    PubMed

    Larson, Elaine L; Cohen, Bevin; Baxter, Kathleen A

    2012-11-01

    Minimal research has been published evaluating the effectiveness of hand hygiene delivery systems (ie, rubs, foams, or wipes) at removing viruses from hands. The purposes of this study were to determine the effect of several alcohol-based hand sanitizers in removing influenza A (H1N1) virus, and to compare the effectiveness of foam, gel, and hand wipe products. Hands of 30 volunteers were inoculated with H1N1 and randomized to treatment with foam, gel, or hand wipe applied to half of each volunteer's finger pads. The log(10) count of each subject's treated and untreated finger pads were averaged. Log(10) reductions were calculated from these differences and averaged within treatment group. Between-treatment analysis compared changes from the untreated finger pads using analysis of covariance with treatment as a factor and the average log(10) untreated finger pads as the covariate. Log(10) counts on control finger pads were 2.7-5.3 log(10) of the 50% infectious dose for tissue culture (TCID(50)/0.1 mL) (mean, 3.8 ± 0.5 log(10) TCID(50)/0.1 mL), and treated finger pad counts for all test products were 0.5-1.9 log(10) TCID(50)/0.1 mL (mean, 0.53 ± 0.17 log(10) TCID(50)/0.1 mL). Treatments with all products resulted in a significant reduction in viral titers (>3 logs) at their respective exposure times that were statistically comparable. All 3 delivery systems (foam, gel, and wipe) produced significantly reduced viral counts on hands. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  3. Quality improvement program for the B83 bomb hand truck

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loll, M.B.; Buck, S.A.

    1998-04-01

    This report describes the problems, issues, and history of the H1347 bomb hand truck for the B83 bomb after the bomb was put into stockpile in the mid-1980s. Major issues that were reported in Unsatisfactory Reports (URs) were cracking problems on stacking fixture welds, cracked welds on the caster bracket receptacles on the cradle, cracked caster mounting brackets, casters unlocking from the swivel lock position, and caster tires rubbing and binding on the stacking frame. Resolution of these and other problems is described. The introduction of the H695B storage-only bomb hand truck to alleviate a shortage of bomb hand trucksmore » in the mid-1990s is described. The development and qualification of the H1347A bomb hand truck as a replacement for the H695 B is covered. The results from load test evaluations on the stacking fixture, cradle, and casters for the H1347 are described along with towing results on one and two-high stack configurations of B83 bombs in bomb hand trucks. New towing and truck/trailer transport procedures are described. Development, evaluation, and production recommendations for a stronger caster mounting bracket are described.« less

  4. Rubbing time and bonding performance of one-step adhesives to primary enamel and dentin

    PubMed Central

    Botelho, Maria Paula Jacobucci; Isolan, Cristina Pereira; Schwantz, Júlia Kaster; Lopes, Murilo Baena; de Moraes, Rafael Ratto

    2017-01-01

    Abstract Objectives: This study investigated whether increasing the concentration of acidic monomers in one-step adhesives would allow reducing their application time without interfering with the bonding ability to primary enamel and dentin. Material and methods: Experimental one-step self-etch adhesives were formulated with 5 wt% (AD5), 20 wt% (AD20), or 35 wt% (AD35) acidic monomer. The adhesives were applied using rubbing motion for 5, 10, or 20 s. Bond strengths to primary enamel and dentin were tested under shear stress. A commercial etch-and-rinse adhesive (Single Bond 2; 3M ESPE) served as reference. Scanning electron microscopy was used to observe the morphology of bonded interfaces. Data were analysed at p<0.05. Results: In enamel, AD35 had higher bond strength when rubbed for at least 10 s, while application for 5 s generated lower bond strength. In dentin, increased acidic monomer improved bonding only for 20 s rubbing time. The etch-and-rinse adhesive yielded higher bond strength to enamel and similar bonding to dentin as compared with the self-etch adhesives. The adhesive layer was thicker and more irregular for the etch-and-rinse material, with no appreciable differences among the self-etch systems. Conclusion: Overall, increasing the acidic monomer concentration only led to an increase in bond strength to enamel when the rubbing time was at least 10 s. In dentin, despite the increase in bond strength with longer rubbing times, the results favoured the experimental adhesives compared to the conventional adhesive. Reduced rubbing time of self-etch adhesives should be avoided in the clinical setup. PMID:29069150

  5. Electronic and elastic properties of new semiconducting oP(12)-type RuB(2) and OsB(2).

    PubMed

    Hao, Xianfeng; Xu, Yuanhui; Gao, Faming

    2011-03-30

    Using first-principles total energy calculations we investigate the structural, elastic and electronic properties of new hypothetical oP(12)-type phase RuB(2) and OsB(2). The calculations indicate that the oP(12)-type phase RuB(2) and OsB(2) are thermodynamically and mechanically stable. Remarkably, the new phases RuB(2) and OsB(2) are predicted to be semiconductors, and the appearance of band gaps is ascribed to the enhanced B-B covalent hybridization. Compared to metallic oP(6)-type RuB(2) and OsB(2) phases, the new phases possess similar mechanical properties and hardness. The combination of the probability of tunable electronic properties, strong stiffness and high hardness make RuB(2) and OsB(2) attractive and interesting for advanced applications. © 2011 IOP Publishing Ltd

  6. Analysis on accuracy improvement of rotor-stator rubbing localization based on acoustic emission beamforming method.

    PubMed

    He, Tian; Xiao, Denghong; Pan, Qiang; Liu, Xiandong; Shan, Yingchun

    2014-01-01

    This paper attempts to introduce an improved acoustic emission (AE) beamforming method to localize rotor-stator rubbing fault in rotating machinery. To investigate the propagation characteristics of acoustic emission signals in casing shell plate of rotating machinery, the plate wave theory is used in a thin plate. A simulation is conducted and its result shows the localization accuracy of beamforming depends on multi-mode, dispersion, velocity and array dimension. In order to reduce the effect of propagation characteristics on the source localization, an AE signal pre-process method is introduced by combining plate wave theory and wavelet packet transform. And the revised localization velocity to reduce effect of array size is presented. The accuracy of rubbing localization based on beamforming and the improved method of present paper are compared by the rubbing test carried on a test table of rotating machinery. The results indicate that the improved method can localize rub fault effectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Outbreaks where food workers have been implicated in the spread of foodborne disease. Part 9. Washing and drying of hands to reduce microbial contamination.

    PubMed

    Todd, Ewen C D; Michaels, Barry S; Smith, Debra; Greig, Judy D; Bartleson, Charles A

    2010-10-01

    During various daily activities at home and work, hands quickly become contaminated. Some activities increase the risk of finger contamination by pathogens more than others, such as the use of toilet paper to clean up following a diarrheal episode, changing the diaper of a sick infant, blowing a nose, or touching raw food materials. Many foodborne outbreak investigation reports have identified the hands of food workers as the source of pathogens in the implicated food. The most convenient and efficient way of removing pathogens from hands is through hand washing. Important components of hand washing are potable water for rinsing and soaps to loosen microbes from the skin. Hand washing should occur after any activity that soils hands and certainly before preparing, serving, or eating food. Antimicrobial soaps are marginally more effective than plain soaps, but constant use results in a buildup of the antimicrobial compound on the skin. The time taken to wash hands and the degree of friction generated during lathering are more important than water temperature for removing soil and microorganisms. However, excessive washing and scrubbing can cause skin damage and infections. Drying hands with a towel removes pathogens first by friction during rubbing with the drying material and then by wicking away the moisture into that material. Paper rather than cloth towels should be encouraged, although single-use cloth towels are present in the washrooms of higher class hotels and restaurants. Warm air dryers remove moisture and any surface microorganisms loosened by washing from hands by evaporation while the hands are rubbed together vigorously; however, these dryers take too long for efficient use. The newer dryers with high-speed air blades can achieve dryness in 10 to 15 s without hand rubbing.

  8. Two time-series analyses of the impact of antibiotic consumption and alcohol-based hand disinfection on the incidences of nosocomial methicillin-resistant Staphylococcus aureus infection and Clostridium difficile infection.

    PubMed

    Kaier, Klaus; Hagist, Christian; Frank, Uwe; Conrad, Andreas; Meyer, Elisabeth

    2009-04-01

    To determine the impact of antibiotic consumption and alcohol-based hand disinfection on the incidences of nosocomial methicillin-resistant Staphylococcus aureus (MRSA) infection and Clostridium difficile infection (CDI). Two multivariate time-series analyses were performed that used as dependent variables the monthly incidences of nosocomial MRSA infection and CDI at the Freiburg University Medical Center during the period January 2003 through October 2007. The volume of alcohol-based hand rub solution used per month was quantified in liters per 1,000 patient-days. Antibiotic consumption was calculated in terms of the number of defined daily doses per 1,000 patient-days per month. The use of alcohol-based hand rub was found to have a significant impact on the incidence of nosocomial MRSA infection (P< .001). The multivariate analysis (R2=0.66) showed that a higher volume of use of alcohol-based hand rub was associated with a lower incidence of nosocomial MRSA infection. Conversely, a higher level of consumption of selected antimicrobial agents was associated with a higher incidence of nosocomial MRSA infection. This analysis showed this relationship was the same for the use of second-generation cephalosporins (P= .023), third-generation cephalosporins (P= .05), fluoroquinolones (P= .01), and lincosamides (P= .05). The multivariate analysis (R2=0.55) showed that a higher level of consumption of third-generation cephalosporins (P= .008), fluoroquinolones (P= .084), and/or macrolides (P= .007) was associated with a higher incidence of CDI. A correlation with use of alcohol-based hand rub was not detected. In 2 multivariate time-series analyses, we were able to show the impact of hand hygiene and antibiotic use on the incidence of nosocomial MRSA infection, but we found no association between hand hygiene and incidence of CDI.

  9. Bilateral Glaucomatous Optic Neuropathy Caused by Eye Rubbing.

    PubMed

    Savastano, Alfonso; Savastano, Maria Cristina; Carlomusto, Laura; Savastano, Silvio

    2015-01-01

    In this report, we describe a particular condition of a 52-year-old man who showed advanced bilateral glaucomatous-like optic disc damage, even though the intraocular pressure resulted normal during all examinations performed. Visual field test, steady-state pattern electroretinogram, retinal nerve fiber layer and retinal tomographic evaluations were performed to evaluate the optic disc damage. Over a 4-year observational period, his visual acuity decreased to 12/20 in the right eye and counting fingers in the left eye. Visual fields were severely compromised, and intraocular pressure values were not superior to 14 mm Hg during routine examinations. An accurate anamnesis and the suspicion of this disease represent a crucial aspect to establish the correct diagnosis. In fact, our patient strongly rubbed his eyes for more than 10 h per day. Recurrent and continuous eye rubbing can induce progressive optic neuropathy, causing severe visual field damage similar to the pathology of advanced glaucoma.

  10. Rotor-to-stator rub vibration in centrifugal compressor

    NASA Technical Reports Server (NTRS)

    Gao, J. J.; Qi, Q. M.

    1985-01-01

    One example of excessive vibration encountered during loading of a centrifugal compressor train (H type compressor with HP casing) is discussed. An investigation was made of the effects of the dynamic load on the bearing stiffness and the rotor-bearing system critical speed. The high vibration occurred at a "threshold load," but the machine didn't run smoothly due to rubs even when it had passed through the threshold load. The acquisition and discussion of the data taken in the field as well as a description of the case history which utilizes background information to identify the malfunction conditions is presented. The analysis shows that the failures, including full reverse precession rub and exact one half subharmonic vibration, were caused by the oversize bearings and displacement of the rotor center due to foundation deformation and misalignment between gear shafts, etc. The corrective actions taken to alleviate excessive vibration and the problems which remain to be solved are also presented.

  11. Video observation of hand hygiene practices during routine companion animal appointments and the effect of a poster intervention on hand hygiene compliance

    PubMed Central

    2014-01-01

    Background Hand hygiene is considered one of the most important infection control measures in human healthcare settings, but there is little information available regarding hand hygiene frequency and technique used in veterinary clinics. The objectives of this study were to describe hand hygiene practices associated with routine appointments in companion animal clinics in Ontario, and the effectiveness of a poster campaign to improve hand hygiene compliance. Results Observation of hand hygiene practices was performed in 51 clinics for approximately 3 weeks each using 2 small wireless surveillance cameras: one in an exam room, and one in the most likely location for hand hygiene to be performed outside the exam room following an appointment. Data from 38 clinics were included in the final analysis, including 449 individuals, 1139 appointments before and after the poster intervention, and 10894 hand hygiene opportunities. Overall hand hygiene compliance was 14% (1473/10894), while before and after patient contact compliance was 3% (123/4377) and 26% (1145/4377), respectively. Soap and water was used for 87% (1182/1353) of observed hand hygiene attempts with a mean contact time of 4 s (median 2 s, range 1-49 s), while alcohol-based hand rub (ABHR) was used for 7% (98/1353) of attempts with a mean contact time of 8 s (median 7 s, range 1-30 s). The presence of the posters had no significant effect on compliance, although some staff reported that they felt the posters did increase their personal awareness of the need to perform hand hygiene, and the posters had some effect on product contact times. Conclusions Overall hand hygiene compliance in veterinary clinics in this study was low, and contact time with hand hygiene products was frequently below current recommendations. Use of ABHR was low despite its advantages over hand washing and availability in the majority of clinics. The poster campaign had a limited effect on its own, but could still be used as a

  12. Video observation of hand hygiene practices during routine companion animal appointments and the effect of a poster intervention on hand hygiene compliance.

    PubMed

    Anderson, Maureen E C; Sargeant, Jan M; Weese, J Scott

    2014-05-07

    Hand hygiene is considered one of the most important infection control measures in human healthcare settings, but there is little information available regarding hand hygiene frequency and technique used in veterinary clinics. The objectives of this study were to describe hand hygiene practices associated with routine appointments in companion animal clinics in Ontario, and the effectiveness of a poster campaign to improve hand hygiene compliance. Observation of hand hygiene practices was performed in 51 clinics for approximately 3 weeks each using 2 small wireless surveillance cameras: one in an exam room, and one in the most likely location for hand hygiene to be performed outside the exam room following an appointment. Data from 38 clinics were included in the final analysis, including 449 individuals, 1139 appointments before and after the poster intervention, and 10894 hand hygiene opportunities. Overall hand hygiene compliance was 14% (1473/10894), while before and after patient contact compliance was 3% (123/4377) and 26% (1145/4377), respectively. Soap and water was used for 87% (1182/1353) of observed hand hygiene attempts with a mean contact time of 4 s (median 2 s, range 1-49 s), while alcohol-based hand rub (ABHR) was used for 7% (98/1353) of attempts with a mean contact time of 8 s (median 7 s, range 1-30 s). The presence of the posters had no significant effect on compliance, although some staff reported that they felt the posters did increase their personal awareness of the need to perform hand hygiene, and the posters had some effect on product contact times. Overall hand hygiene compliance in veterinary clinics in this study was low, and contact time with hand hygiene products was frequently below current recommendations. Use of ABHR was low despite its advantages over hand washing and availability in the majority of clinics. The poster campaign had a limited effect on its own, but could still be used as a component of a multimodal hand

  13. Opportunity's 'Rub al Khali' Panorama

    NASA Technical Reports Server (NTRS)

    2005-01-01

    [figure removed for brevity, see original site] Click on the image for Opportunity's 'Rub al Khali' Panorama (QTVR)

    This panoramic image, dubbed 'Rub al Khali,' was acquired by NASA's Mars Exploration Rover Opportunity on the plains of Meridiani during the period from the rover's 456th to 464th sols on Mars (May 6 to May 14, 2005). Opportunity was about 2 kilometers (1.2 miles) south of 'Endurance Crater' at a place known informally as 'Purgatory Dune.'

    The rover was stuck in the dune's deep fine sand for more than a month. 'Rub al Khali' (Arabic translation: 'the empty quarter') was chosen as the name for this panorama because it is the name of a similarly barren, desolate part of the Saudi Arabian desert on Earth.

    The view spans 360 degrees. It consists of images obtained in 97 individual pointings of the panoramic camera. The camera took images with five camera filters at each pointing. This 22,780-by-6,000-pixel mosaic is an approximately true-color rendering generated using the images acquired through filters admitting light wavelengths of 750, 530, and 480 nanometers.

    Lighting varied during the nine sols it took to acquire this panorama, resulting in some small image seams within the mosaic. These seams have been smoothed in sky parts of the mosaic to better simulate the vista that a person would see if able to view it all at the same time on Mars.

    Opportunity's tracks leading back to the north (center of the panorama) are a reminder of the rover's long trek from Endurance Crater. The deep ruts dug by Opportunity's wheels as it became stuck in the sand appear in the foreground. The crest and trough of the last ripple the rover crossed before getting stuck is visible in the center. These wind-formed sand features are only about 10 to 15 centimeters (4 to 6 inches) tall. The crest of the actual ripple where the rover got stuck can be seen just to the right of center. The tracks and a few other places on and near ripple crests can

  14. [Products for hand hygiene and antisepsis: use by health professionals and relationship with hand eczema].

    PubMed

    Batalla, A; García-Doval, I; de la Torre, C

    2012-04-01

    Hand hygiene is the most important measure for the prevention of nosocomial infection. We describe the different products available for hygiene and antisepsis of the hands and the use of these products in daily practice. Hand hygiene products such as soaps and detergents are a cause of irritant dermatitis in health professionals. This irritation is one of the principal factors affecting their use in clinical practice. Alcohol-based products are better tolerated and less irritant than soap and water; irritation should not therefore be a limiting factor in the use of these products and they are to be recommended in place of soap and water. Informative and continued education programs could increase their use. Copyright © 2011 Elsevier España, S.L. and AEDV. All rights reserved.

  15. An Australian Response to Michael Bérubé

    ERIC Educational Resources Information Center

    Frances, Raelene

    2016-01-01

    This article supports Bérubé's conclusion regarding the intellectual health of humanities scholarship. However, it argues that the case of "contingent faculty"--or academics with short-term or casual contracts--is in many respects different in Australia to the situation he outlines for the US. Whilst a variety of funding pressures have…

  16. How a smiley protects health: A pilot intervention to improve hand hygiene in hospitals by activating injunctive norms through emoticons

    PubMed Central

    Tsivrikos, Dimitrios; Dollinger, Daniel; Lermer, Eva

    2018-01-01

    Hand hygiene practice in hospitals is unfortunately still widely insufficient, even though it is known that transmitting pathogens via hands is the leading cause of healthcare-associated infections. Previous research has shown that improving knowledge, providing feedback on past behaviour and targeting social norms are promising approaches to improve hand hygiene practices. The present field experiment was designed to direct people on when to perform hand hygiene and prevent forgetfulness. This intervention is the first to examine the effect of inducing injunctive social norms via an emoticon-based feedback system on hand hygiene behaviour. Electronic monitoring and feedback devices were installed in hospital patient rooms on top of hand-rub dispensers, next to the doorway, for a period of 17 weeks. In the emoticon condition, screens at the devices activated whenever a person entered or exited the room. Before using the alcohol-based hand-rub dispenser, a frowny face was displayed, indicating that hand hygiene should be performed. If the dispenser was subsequently used, this picture changed to a smiley face to positively reinforce the correct behaviour. Hand hygiene behaviour in the emoticon rooms significantly outperformed the behaviour in three other tested conditions. The strong effect in this field experiment indicates that activating injunctive norms may be a promising approach to improve hand hygiene behaviour. Theoretical and practical implications of these findings are discussed. PMID:29782516

  17. Theoretical and experimental investigation on the sudden unbalance and rub-impact in rotor system caused by blade off

    NASA Astrophysics Data System (ADS)

    Wang, Cun; Zhang, Dayi; Ma, Yanhong; Liang, Zhichao; Hong, Jie

    2016-08-01

    Blade loss from a running turbofan rotor will introduce sudden unbalance into the dynamical system, and as a consequence leads to the rub-impact, the asymmetry of rotor and a series of interesting dynamic characteristics. The paper focuses on the theoretical study on the sudden unbalance and rub-impact caused by blade loss, in particular investigates the response of the rotor on a rotor test rig with sudden unbalance and rub-impact device designed respectively. The results reveal that the sudden unbalance will induce impact effect on the rotor, and critical speed frequency is excited in frequency spectrum. Meantime, the impact effect is more obvious for the rotor operating above critical speed. The influence of rub-impact is considered as additional constraint to the rotor, analyzed by the theory of time-varying system for the first time, and the results are evaluated by experimental tests. The study shows that great attention should be paid to the dynamical design for the overhung rotor system, additional constraint and corresponding analysis method in rub-impact need to be intensively studied.

  18. An evaluation of hospital hand hygiene practice and glove use in Hong Kong.

    PubMed

    Chau, Janita P-C; Thompson, David R; Twinn, Sheila; Lee, Diana T F; Pang, Sharon W M

    2011-05-01

    To identify omissions in hand hygiene practice and glove use among hospital workers in Hong Kong. Hospital-acquired infection is the commonest complication affecting hospitalised patients. Even though research evidence suggests that hand hygiene and proper glove use are the most important ways to prevent the spread of disease and infection, compliance with both are reported to be unacceptably low. An observational study of hospital workers in one acute and two convalescence and rehabilitation hospitals in Hong Kong was conducted. The participating clinical areas included the medical and surgical wards, accident and emergency department and intensive care unit. Hand hygiene practice and glove use amongst 206 hospital health and support workers, stratified according to years of working experience, were observed. The number of observed episodes for hand hygiene was 1037 and for glove use 304. Compliance with hand hygiene was 74.7% and with glove use 72.4%. In approximately two-third of episodes, participants washed their hands after each patient contact; though, 78.5% failed to rub their hands together vigorously for at least 15 seconds. The major break in compliance with glove use was failure to change gloves between procedures on the same patient. In 28.6% of observed glove use episodes, participants did not wear gloves during procedures that exposed them to blood, body fluids, excretion, non-intact skin or mucous membranes. Significant differences in performance scores on antiseptic hand rub were found between the two types of hospital and on glove use between the three groups of work experience: ≤ 5, 6-10, >10 years. Education and reinforcement of proper hand hygiene practice and glove use among hospital health and support workers is needed. © 2011 Blackwell Publishing Ltd.

  19. Effects of eye rubbing on the levels of protease, protease activity and cytokines in tears: relevance in keratoconus.

    PubMed

    Balasubramanian, Sivaraman A; Pye, David C; Willcox, Mark D P

    2013-03-01

    Proteases, protease activity and inflammatory molecules in tears have been found to be relevant in the pathogenesis of keratoconus. We sought to determine the influence of eye rubbing on protease expression, protease activity and concentration of inflammatory molecules in tears. Basal tears were collected from normal volunteers before and after 60 seconds of experimental eye rubbing. The total amount of matrix metalloproteinase (MMP)-13 and inflammatory molecules interleukin (IL)-6 and tumour necrosis factor (TNF)-α in the tear samples were measured using specific enzyme-linked immunosorbent assays (ELISA). Tear collagenase activity was investigated using a specific activity assay. The concentrations of MMP-13 (51.9 ± 34.3 versus 63 ± 36.8 pg/ml, p = 0.006), IL-6 (1.24 ± 0.98 versus 2.02 ± 1.52 pg/ml, p = 0.004) and TNF-α (1.16 ± 0.74 versus 1.44 ± 0.66 pg/ml, p = 0.003) were significantly increased in normal subjects after eye rubbing. The experimental eye rub did not alter significantly the collagenase activity (5.02 ± 3 versus 7.50 ± 3.90 fluorescent intensity units, p = 0.14) of tears. Eye rubbing for 60 seconds increased the level of tear MMP-13, IL-6 and TNF-α in normal study subjects. This increase in protease, protease activity and inflammatory mediators in tears after eye rubbing may be exacerbated even further during persistent and forceful eye rubbing seen in people with keratoconus and this in turn may contribute to the progression of the disease. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  20. Severe acute corneal hydrops in a patient with Down syndrome and persistent eye rubbing.

    PubMed

    Ozcan, Altan A; Ersoz, T Reha

    2007-01-01

    We report a case of severe acute corneal hydrops in an 11-year-old boy with keratoconus associated with Down syndrome and vigorous eye rubbing. Complete resolution of the corneal edema and a central corneal scar was seen in the 8th week of final follow-up. Eye-rubbing may play a role in the pathogenesis of acute hydrops, and conventional therapy can be successful in its management, even in severe cases.

  1. Contact dermatitis to Vicks VapoRub.

    PubMed

    Noiles, Kristin; Pratt, Melanie

    2010-01-01

    Vicks VapoRub (VVR) is a commonly used inhalant ointment that helps relieve symptoms of upper respiratory tract infections. It contains several plant substances, including turpentine oil, eucalyptus oil, and cedar leaf oil, which can potentially irritate or sensitize the skin, as well as camphor, menthol, nutmeg oil, and thymol. Although many reports describe allergic contact dermatitis (ACD) to the various constituents in VVR ointment, there are no cases of VVR directly causing ACD. We present a case of a patient who developed an ACD secondary to application of her VVR.

  2. Evaluation of the national Cleanyourhands campaign to reduce Staphylococcus aureus bacteraemia and Clostridium difficile infection in hospitals in England and Wales by improved hand hygiene: four year, prospective, ecological, interrupted time series study

    PubMed Central

    Fuller, Christopher; Savage, Joan; Cookson, Barry; Hayward, Andrew; Cooper, Ben; Duckworth, Georgia; Michie, Susan; Murray, Miranda; Jeanes, Annette; Roberts, J; Teare, Louise; Charlett, Andre

    2012-01-01

    Objective To evaluate the impact of the Cleanyourhands campaign on rates of hospital procurement of alcohol hand rub and soap, report trends in selected healthcare associated infections, and investigate the association between infections and procurement. Design Prospective, ecological, interrupted time series study from 1 July 2004 to 30 June 2008. Setting 187 acute trusts in England and Wales. Intervention Installation of bedside alcohol hand rub, materials promoting hand hygiene and institutional engagement, regular hand hygiene audits, rolled out nationally from 1 December 2004. Main outcome measures Quarterly (that is, every three months) rates for each trust of hospital procurement of alcohol hand rub and liquid soap; Staphylococcus aureus bacteraemia (meticillin resistant (MRSA) and meticillin sensitive (MSSA)) and Clostridium difficile infection for each trust. Associations between procurement and infection rates assessed by mixed effect Poisson regression model (which also accounted for effect of bed occupancy, hospital type, and timing of other national interventions targeting these infections). Results Combined procurement of soap and alcohol hand rub tripled from 21.8 to 59.8 mL per patient bed day; procurement rose in association with each phase of the campaign. Rates fell for MRSA bacteraemia (1.88 to 0.91 cases per 10 000 bed days) and C difficile infection (16.75 to 9.49 cases). MSSA bacteraemia rates did not fall. Increased procurement of soap was independently associated with reduced C difficile infection throughout the study (adjusted incidence rate ratio for 1 mL increase per patient bed day 0.993, 95% confidence interval 0.990 to 0.996; P<0.0001). Increased procurement of alcohol hand rub was independently associated with reduced MRSA bacteraemia, but only in the last four quarters of the study (0.990, 0.985 to 0.995; P<0.0001). Publication of the Health Act 2006 was strongly associated with reduced MRSA bacteraemia (0.86, 0.75 to 0.98; P=0

  3. Evaluation of the national Cleanyourhands campaign to reduce Staphylococcus aureus bacteraemia and Clostridium difficile infection in hospitals in England and Wales by improved hand hygiene: four year, prospective, ecological, interrupted time series study.

    PubMed

    Stone, Sheldon Paul; Fuller, Christopher; Savage, Joan; Cookson, Barry; Hayward, Andrew; Cooper, Ben; Duckworth, Georgia; Michie, Susan; Murray, Miranda; Jeanes, Annette; Roberts, J; Teare, Louise; Charlett, Andre

    2012-05-03

    To evaluate the impact of the Cleanyourhands campaign on rates of hospital procurement of alcohol hand rub and soap, report trends in selected healthcare associated infections, and investigate the association between infections and procurement. Prospective, ecological, interrupted time series study from 1 July 2004 to 30 June 2008. 187 acute trusts in England and Wales. Installation of bedside alcohol hand rub, materials promoting hand hygiene and institutional engagement, regular hand hygiene audits, rolled out nationally from 1 December 2004. Quarterly (that is, every three months) rates for each trust of hospital procurement of alcohol hand rub and liquid soap; Staphylococcus aureus bacteraemia (meticillin resistant (MRSA) and meticillin sensitive (MSSA)) and Clostridium difficile infection for each trust. Associations between procurement and infection rates assessed by mixed effect Poisson regression model (which also accounted for effect of bed occupancy, hospital type, and timing of other national interventions targeting these infections). Combined procurement of soap and alcohol hand rub tripled from 21.8 to 59.8 mL per patient bed day; procurement rose in association with each phase of the campaign. Rates fell for MRSA bacteraemia (1.88 to 0.91 cases per 10,000 bed days) and C difficile infection (16.75 to 9.49 cases). MSSA bacteraemia rates did not fall. Increased procurement of soap was independently associated with reduced C difficile infection throughout the study (adjusted incidence rate ratio for 1 mL increase per patient bed day 0.993, 95% confidence interval 0.990 to 0.996; P < 0.0001). Increased procurement of alcohol hand rub was independently associated with reduced MRSA bacteraemia, but only in the last four quarters of the study (0.990, 0.985 to 0.995; P < 0.0001). Publication of the Health Act 2006 was strongly associated with reduced MRSA bacteraemia (0.86, 0.75 to 0.98; P = 0.02) and C difficile infection (0.75, 0.67 to 0.84; P < 0

  4. Turbine Engine Stability/Instability With Rub Forces Axisymmetric Rotor-Support Stiffness

    NASA Technical Reports Server (NTRS)

    Gallardo, Vicente; Lawrence, Charles

    2004-01-01

    The stability/instability condition of a turbine rotor with axisymmetric supports is determined in the presence of gyroscopic loads and rub-induced destabilizing forces. A modal representation of the turbine engine is used, with one mode in each of the vertical and horizontal planes. The use of non-spinning rotor modes permits an explicit treatment of gyroscopic effects. The two linearized modal equations of motion of a rotor with axisymmetric supports are reduced to a single equation in a complex variable. The resulting eigenvalues yield explicit expressions at the stability boundary, for the whirl frequency as well as the required damping for stability in the presence of the available rub-induced destabilization. Conversely, the allowable destabilization in the presence of the available damping is also given.

  5. 17. Jet Lowe, Photographer, June 1978. FIVEROLL RUB DELIVERY ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. Jet Lowe, Photographer, June 1978. FIVE-ROLL RUB DELIVERY ON A. JENKS & SON FINISHER CARD; THE DELIVERY IS CONSISTENT WITH MANUFACTURE C. 1845-1855; FROM RIGHT FRONT OF OSCILLATING MECHANISM. - Watkins Mill, County Highway MM, Lawson, Ray County, MO

  6. Head rubbing and licking reinforce social bonds in a group of captive African lions, Panthera leo.

    PubMed

    Matoba, Tomoyuki; Kutsukake, Nobuyuki; Hasegawa, Toshikazu

    2013-01-01

    Many social animals have a species-specific repertoire of affiliative behaviours that characterise individualised relationships within a group. To date, however, quantitative studies on intragroup affiliative behaviours in social carnivores have been limited. Here, we investigated the social functions of the two most commonly observed affiliative behaviours in captive African lions (Panthera leo): head rubbing and licking. We conducted behavioural observations on a captive group of lions composed of 7 males and 14 females, and tested hypotheses regarding three social functions: tension reduction, social bonding, and social status expression. Disproportionately frequent male-male and female-to-male head rubbing was observed, while more than 95% of all licking interactions occurred in female-female dyads. In accordance with the social bond hypothesis, and in disagreement with the social status expression hypothesis, both head rubbing and licking interactions were reciprocal. After controlling for spatial association, the dyadic frequency of head rubbing was negatively correlated with age difference while licking was positively correlated with relatedness. Group reunion after daily separation did not affect the frequencies of the affiliative behaviours, which was in disagreement with the predictions from the tension reduction hypothesis. These results support the social bond hypothesis for the functions of head rubbing and licking. Different patterns of affiliative behaviour between the sexes may reflect differences in the relationship quality in each sex or the differential predisposition to licking due to its original function in offspring care.

  7. Production rates for crews using hand tools on firelines

    Treesearch

    Lisa Haven; T. Parkin Hunter; Theodore G. Storey

    1982-01-01

    Reported rates at which hand crews construct firelines can vary widely because of differences in fuels, fire and measurement conditions, and fuel resistance-to-control classification schemes. Real-time fire dispatching and fire simulation planning models, however, require accurate estimates of hand crew productivity. Errors in estimating rate of fireline production...

  8. Structural geology of the Rub' Al-Khali Basin, Saudi Arabia

    NASA Astrophysics Data System (ADS)

    Stewart, S. A.

    2016-10-01

    The Rub' Al-Khali basin lies below a Quaternary sand sea, and the structural evolution from the Late Precambrian to Neogene is known only from reflection seismic, gravity, and magnetic data, and wells. Gravity and magnetic data show north-south and northwest-southeast trends, matching mapped Precambrian faults. The deepest structures imaged on reflection seismic data are undrilled Precambrian rifts filled with layered strata at depths up to 13 km. The distribution of Ediacaran-Cambrian Ara/Hormuz mobile salt is restricted to an embayment in the eastern Rub' Al-Khali. The Precambrian rifts show local inversion and were peneplained at base Phanerozoic. A broad crustal-scale fold (Qatar Arch) developed in the Carboniferous and amplified in the Late Triassic, separating subbasins in the west and east Rub' Al-Khali. A phase of kilometer-scale folding occurred in the Late Cretaceous, coeval with thrusting and ophiolite obduction in eastern Oman. These folds trend predominantly north-south, oblique to the northwesterly shortening direction, and occasionally have steep fault zones close to their axial surfaces. The trend and location of these folds closely matches the Precambrian lineaments identified in this study, demonstrating preferential reactivation of basement structures. Compression along the Zagros suture reactivated these folds in the Neogene, this time the result of highly oblique, north-northeast to south-southwest shortening. Cretaceous-Tertiary fold style is interpreted as transpression with minor strain partitioning. Permian, Jurassic, and Eocene evaporite horizons played no role in the structural evolution of the basin, but the Eocene evaporites caused widespread kilometer-scale dissolution collapse structures in the basin center.

  9. The hammer QSD-quick stop device for high speed machining and rubbing

    NASA Technical Reports Server (NTRS)

    Black, J. T.; James, C. R.

    1980-01-01

    A quick stop device (QSD) was designed for use in orthogonal machining and rubbing experiments. QSD's are used to obtain chip root samples that are representative of the deformation taking place during dynamic (actual) cutting conditions. These 'frozen' specimens are helpful in examining the plastic deformation that occurs in the regions of compression and shear which form the chip; the secondary shear at the tool-chip interface; and the nose ploughing/flank rubbing action which operates on the newly machined surface. The Hammer QSD employs a shear pin mechanism, broken by a flying hammer, which is traveling at the same velocity as the workpiece. The device has been successfully tested up to 6000 sfpm (30.48 m/sec).

  10. Analytical and experimental investigation of rubbing interaction in labyrinth seals for a liquid hydrogen fuel pump. [space shuttle main engine

    NASA Technical Reports Server (NTRS)

    Dolan, F. X.; Kennedy, F. E.; Schulson, E. M.

    1984-01-01

    Cracking of the titanium knife edges on the labyrinth seals of the liquid hydrogen fuel pump in the Space Shuttle main engine is considered. Finite element analysis of the thermal response of the knife edge in sliding contact with the wear ring surface shows that interfacial temperatures can be quite high and they are significantly influenced by the thermal conductivity of the surfaces in rubbing contact. Thermal shock experiments on a test specimen similar to the knife edge geometry demonstrate that cracking of the titanium alloy is possible in a situation involving repeated thermal cycles over a wide temperature range, as might be realized during a rub in the liquid hydrogen fuel pump. High-speed rub interaction tests were conducted using a representative knife edge and seal geometry over a broad range of interaction rates and alternate materials were experimentally evaluated. Plasma-sprayed aluminum-graphite was found to be significantly better than presently used aluminum alloy seals from the standpoint of rub performance. Ion nitriding the titanium alloy knife-edges also improved rub performance compared to the untreated baseline.

  11. A finite element-based algorithm for rubbing induced vibration prediction in rotors

    NASA Astrophysics Data System (ADS)

    Behzad, Mehdi; Alvandi, Mehdi; Mba, David; Jamali, Jalil

    2013-10-01

    In this paper, an algorithm is developed for more realistic investigation of rotor-to-stator rubbing vibration, based on finite element theory with unilateral contact and friction conditions. To model the rotor, cross sections are assumed to be radially rigid. A finite element discretization based on traditional beam theories which sufficiently accounts for axial and transversal flexibility of the rotor is used. A general finite element discretization model considering inertial and viscoelastic characteristics of the stator is used for modeling the stator. Therefore, for contact analysis, only the boundary of the stator is discretized. The contact problem is defined as the contact between the circular rigid cross section of the rotor and “nodes” of the stator only. Next, Gap function and contact conditions are described for the contact problem. Two finite element models of the rotor and the stator are coupled via the Lagrange multipliers method in order to obtain the constrained equation of motion. A case study of the partial rubbing is simulated using the algorithm. The synchronous and subsynchronous responses of the partial rubbing are obtained for different rotational speeds. In addition, a sensitivity analysis is carried out with respect to the initial clearance, the stator stiffness, the damping parameter, and the coefficient of friction. There is a good agreement between the result of this research and the experimental result in the literature.

  12. Chromosome-Encoded Broad-Spectrum Ambler Class A β-Lactamase RUB-1 from Serratia rubidaea

    PubMed Central

    Didi, Jennifer; Ergani, Ayla; Lima, Sandra

    2016-01-01

    ABSTRACT Whole-genome sequencing of Serratia rubidaea CIP 103234T revealed a chromosomally located Ambler class A β-lactamase gene. The gene was cloned, and the β-lactamase, RUB-1, was characterized. RUB-1 displayed 74% and 73% amino acid sequence identity with the GIL-1 and TEM-1 penicillinases, respectively, and its substrate profile was similar to that of the latter β-lactamases. Analysis by 5′ rapid amplification of cDNA ends revealed promoter sequences highly divergent from the Escherichia coli σ70 consensus sequence. This work further illustrates the heterogeneity of β-lactamases among Serratia spp. PMID:27956418

  13. Hand hygiene and healthcare system change within multi-modal promotion: a narrative review.

    PubMed

    Allegranzi, B; Sax, H; Pittet, D

    2013-02-01

    Many factors may influence the level of compliance with hand hygiene recommendations by healthcare workers. Lack of products and facilities as well as their inappropriate and non-ergonomic location represent important barriers. Targeted actions aimed at making hand hygiene practices feasible during healthcare delivery by ensuring that the necessary infrastructure is in place, defined as 'system change', are essential to improve hand hygiene in healthcare. In particular, access to alcohol-based hand rubs (AHRs) enables appropriate and timely hand hygiene performance at the point of care. The feasibility and impact of system change within multi-modal strategies have been demonstrated both at institutional level and on a large scale. The introduction of AHRs overcomes some important barriers to best hand hygiene practices and is associated with higher compliance, especially when integrated within multi-modal strategies. Several studies demonstrated the association between AHR consumption and reduction in healthcare-associated infection, in particular, meticillin-resistant Staphylococcus aureus bacteraemia. Recent reports demonstrate the feasibility and success of system change implementation on a large scale. The World Health Organization and other investigators have reported the challenges and encouraging results of implementing hand hygiene improvement strategies, including AHR introduction, in settings with limited resources. This review summarizes the available evidence demonstrating the need for system change and its importance within multi-modal hand hygiene improvement strategies. This topic is also discussed in a global perspective and highlights some controversial issues. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  14. Going Dotty: a practical guide for installing new hand hygiene products.

    PubMed

    Bush, Kathryn; Mah, Manuel W; Meyers, Gwyneth; Armstrong, Pamela; Stoesz, Janice; Strople, Sally

    2007-12-01

    This report distills our experiences coordinating the installation of a new commercial line of hand hygiene products in a large, integrated health care region in Western Canada into a practical guide that can benefit infection control professionals. Some key considerations while managing such a large hand hygiene products installation are stakeholder collaboration, management of occupational hand dermatitis, housekeeping support, and communication.

  15. Chromosome-Encoded Broad-Spectrum Ambler Class A β-Lactamase RUB-1 from Serratia rubidaea.

    PubMed

    Bonnin, Rémy A; Didi, Jennifer; Ergani, Ayla; Lima, Sandra; Naas, Thierry

    2017-02-01

    Whole-genome sequencing of Serratia rubidaea CIP 103234 T revealed a chromosomally located Ambler class A β-lactamase gene. The gene was cloned, and the β-lactamase, RUB-1, was characterized. RUB-1 displayed 74% and 73% amino acid sequence identity with the GIL-1 and TEM-1 penicillinases, respectively, and its substrate profile was similar to that of the latter β-lactamases. Analysis by 5' rapid amplification of cDNA ends revealed promoter sequences highly divergent from the Escherichia coli σ 70 consensus sequence. This work further illustrates the heterogeneity of β-lactamases among Serratia spp. Copyright © 2017 American Society for Microbiology.

  16. [Influence of promotional material on hand hygiene in the safety culture of a tertiary hospital].

    PubMed

    Molina-Cabrillana, J; Dorta-Hung, M E; Otero Sanz, L; Henández Vera, J R; Martín-Rodríguez, M M; García de Carlos, P

    2016-06-01

    In order to increase safety culture about hand hygiene by means of messages and reminders about its importance in preventing nosocomial infections, we developed a new set of materials in the Complejo Hospitalario Universitario Insular Materno-Infantil of Las Palmas, Gran Canaria, constitued by two centres with 450 beds each and acredited for medical internal residents training. We hired a well-known caricaturist, who adapted the messages to the local way of speaking, by using characters that used to appear in his artwork in the local newspaper. Also, we continued to work with other graphic design professionals. We monitored adherence and consumption of products for hand rubbing. We noted an increase in both indicators in the following months after the implementation of this strategy. Moreover, we revised the infrastructures for hand hygiene, and were able to demonstrate improvements in most of the patient care areas. The material was well accepted by professionals, patients and visitors. No other interventions were made, so we think improvements can be attributable to this strategy in our setting. Copyright © 2016 SECA. Published by Elsevier Espana. All rights reserved.

  17. In-vivo efficacy of hand sanitisers against feline calicivirus: a surrogate for norovirus.

    PubMed

    Lages, S L S; Ramakrishnan, M A; Goyal, S M

    2008-02-01

    Hand disinfection is considered important in preventing the transmission of viruses, including norovirus. We investigated the virucidal efficacy of nine hand sanitisers (four alcohol-based sanitisers, three non-alcoholic sanitisers and two triclosan-containing antimicrobial liquid soaps) against feline calicivirus, a surrogate for norovirus, on artificially contaminated fingertips for 30 s and 2 min contact periods. Among alcohol-based sanitisers, a product containing 99.5% ethanol was more effective than those containing 62% ethanol, 70% isopropanol or 91% isopropanol. A log(10) virus reduction factor of 1.00-1.30 was achieved with 99.5% ethanol but those containing a lower alcohol concentration only achieved a log(10) reduction factor of hands without any soap (a log(10) reduction factor of 0.33-0.42). These results indicate that triclosan-containing antimicrobial soaps or alcohol-based hand rubs may be inadequate for preventing norovirus transmission. Further research on alternative hand sanitisers should continue for effective control of norovirus infections.

  18. Triple dye plus rubbing alcohol versus triple dye alone for umbilical cord care.

    PubMed

    Suliman, Alawia K; Watts, Heidi; Beiler, Jessica; King, Tonya S; Khan, Sana; Carnuccio, Marybeth; Paul, Ian M

    2010-01-01

    Current practices for umbilical cord care vary across centers, but the evidence regarding these practices and their impact on cord separation, complications, and health care use are limited. The objective of this study was to compare the effect of triple dye alone (brilliant green, crystal violet, and proflavine hemisulfate) versus triple dye plus rubbing alcohol (isopropyl alcohol) twice daily on time to umbilical cord separation, complications, and health care use. For the 90 newborns who completed the study, there were no significant differences between treatment groups for time to cord separation, cord-related morbidities, or cord-related urgent care. Based on these study results, there does not appear to be significant benefit to the addition of twice daily applications of rubbing alcohol to neonatal umbilical cords following triple dye treatment after birth.

  19. Intensified hand-hygiene campaign including soap-and-water wash may prevent acute infections in office workers, as shown by a recognized-exposure -adjusted analysis of a randomized trial.

    PubMed

    Hovi, Tapani; Ollgren, Jukka; Savolainen-Kopra, Carita

    2017-01-09

    Variable exposure to causative agents of acute respiratory (RTI) or gastrointestinal tract infections (GTI) is a significant confounding factor in the analysis of the efficacy of interventions concerning these infections. We had an exceptional opportunity to reanalyze a previously published dataset from a trial assessing the effect of enhanced hand hygiene on the occurrence of RTI or GTI in adults, after adjustment for reported exposure and other covariates. Twenty-one working units (designated clusters) each including at least 50 office employees, totaling 1,270 persons, were randomized into two intervention arms (either using water-and-soap or alcohol-rub in hand cleansing), or in the control arm. Self-reported data was collected through weekly emails and included own symptoms of RTI or GTI, and exposures to other persons with similar symptoms. Differences in the weekly occurrences of RTI and GTI symptoms between the arms were analyzed using multilevel binary regression model with log link with personal and cluster specific random effects, self-reported exposure to homologous disease, randomization triplet, and seasonality as covariates in the Bayesian framework. Over the 16 months duration of the trial, 297 persons in the soap and water arm, 238 persons in the alcohol-based hand rub arm, and 230 controls sent reports. The arms were similar in age distribution and gender ratios. A temporally-associated reported exposure strongly increased the risk of both types of infection in all trial arms. Persons in the soap-and-water arm reported a significantly - about 24% lower weekly prevalence of GTI than the controls whether they had observed an exposure or not during the preceding week, while for RTI, this intervention reduced the prevalence only during weeks without a reported exposure. Alcohol-rub did not affect the symptom prevalence. We conclude that while frequent and careful hand washing with soap and water partially protected office-working adults from GTI, the

  20. Quantitative microbial risk assessment of antibacterial hand hygiene products on risk of shigellosis.

    PubMed

    Schaffner, Donald W; Bowman, James P; English, Donald J; Fischler, George E; Fuls, Janice L; Krowka, John F; Kruszewski, Francis H

    2014-04-01

    There are conflicting reports on whether antibacterial hand hygiene products are more effective than nonantibacterial products in reducing bacteria on hands and preventing disease. This research used new laboratory data, together with simulation techniques, to compare the ability of nonantibacterial and antibacterial products to reduce shigellosis risk. One hundred sixtythree subjects were used to compare five different hand treatments: two nonantibacterial products and three antibacterial products, i.e., 0.46% triclosan, 4% chlorhexidine gluconate, or 62% ethyl alcohol. Hands were inoculated with 5.5 to 6 log CFU Shigella; the simulated food handlers then washed their hands with one of the five products before handling melon balls. Each simulation scenario represented an event in which 100 people would be exposed to Shigella from melon balls that had been handled by food workers with Shigella on their hands. Analysis of experimental data showed that the two nonantibacterial treatments produced about a 2-log reduction on hands. The three antibacterial treatments showed log reductions greater than 3 but less than 4 on hands. All three antibacterial treatments resulted in statistically significantly lower concentration on the melon balls relative to the nonantibacterial treatments. A simulation that assumed 1 million Shigella bacteria on the hands and the use of a nonantibacterial treatment predicted that 50 to 60 cases of shigellosis would result (of 100 exposed). Each of the antibacterial treatments was predicted to result in an appreciable number of simulations for which the number of illness cases would be 0, with the most common number of illness cases being 5 (of 100 exposed). These effects maintained statistical significance from 10(6) Shigella per hand down to as low as 100 Shigella per hand, with some evidence to support lower levels. This quantitative microbial risk assessment shows that antibacterial hand treatments can significantly reduce Shigella risk.

  1. Why language matters: a tour through hand hygiene literature.

    PubMed

    Pires, Daniela; Tartari, Ermira; Bellissimo-Rodrigues, Fernando; Pittet, Didier

    2017-01-01

    Hand hygiene has evolved over the last decades and many terminologies emerged. We aimed to analyse the evolution in the frequency of utilization of key hand hygiene terms in the literature along the years. We identified keywords and Medical Subject Headings (MeSH) used in MEDLINE® indexation related to hand hygiene by searching international guidelines and the MeSH database. We performed a MEDLINE® search combining the selected keywords and MeSH and analysed the number of publications retrieved yearly. The literature search yielded 9019 publications when all hand hygiene related search terms were combined, between 1921 and November 2016. The total number of publications per year increased from a median of 4 (IQR 3, 6) in the 1950's to 554 (IQR 478, 583) between 2011 and 2015. The most frequently used keywords are hand disinfection, hand hygiene, hand washing, handrub, hand sanitizer and alcohol-based hand rub (ABHR). Until the 1990s, hand disinfection and hand washing were the most frequently used terms. Whilst the last decade has seen a remarkable increase in publications mentioning hand disinfection and hand hygiene and for the first time handrub, hand sanitizers and ABHR were introduced in the literature. Hand disinfection, hand hygiene and hand sanitizers are the main MeSH used by MEDLINE®. Since 2013 hand hygiene is the most frequently used MeSH and keyword. The change seen in literature in the last two decades, from hand washing and hand disinfection to hand hygiene, most probably reflect the paradigm shift favouring use of ABHR over soap and water promoted by international guidelines in the early 2000s.

  2. Healthcare professionals' hand hygiene knowledge and beliefs in the United Arab Emirates.

    PubMed

    Ng, Wai Khuan; Shaban, Ramon Z; van de Mortel, Thea

    2017-05-01

    Hand hygiene at key moments during patient care is considered an important infection prevention and control measure to reduce healthcare-associated infections. While there is extensive research in Western settings, there is little in the United Arab Emirates where particular cultural and religious customs are thought to influence hand hygiene behaviour. To examine the hand hygiene knowledge and beliefs of health professionals at a tertiary care hospital in the United Arab Emirates. A mixed methods design employed a survey followed by focus groups with nurses and doctors. A total of 109 participants (13.6%) completed the survey: 96 nurses (88%) and 13 doctors (12%). Doctors' hand hygiene knowledge was slightly higher than that of nurses (78.5% versus 73.5%). There was no significant difference in scores on the hand hygiene beliefs scale between nurses (M = 103.06; SD = 8.0) and doctors (M = 99.00; SD = 10.53; t (80) = 1.55; p = 0.13, two-tailed). Seven categories emerged following transcript analysis. Hand hygiene knowledge scores suggest further hand hygiene education is required, especially on alcohol-based hand rub use. Addressing doctors' beliefs is particularly important given the leadership roles that doctors play in healthcare settings.

  3. New method for determination of efficacy of health care personnel hand wash products.

    PubMed Central

    Mahl, M C

    1989-01-01

    A method of studying the effects of health care personnel hand wash products is described. The fingernail regions of the hands of volunteers are inoculated with a mixture of Escherichia coli and Serratia marcescens, and the areas are dried for a standard time. After routine hand washing, each fingernail region is individually scrubbed with an electric toothbrush which moves longitudinally to the handle into collection fluid contained in a petri dish. The test bacteria in the fluid are then enumerated. (Bacillus subtilis spores may be included as tracers to show degree of physical removal of the procedure.) This method has several advantages over the frequently used glove juice technique. Experimental designs with large numbers of volunteers, multiple sampling sites, and many hand wash products may be performed. Ten sampling sites (fingers) are available, versus the two gloved hands for testing products. (Efficiency is almost 100% in the recovery of spore tracers placed on the fingernails.) Many commercial health care personnel hand wash products containing antimicrobial agents substantive to the skin do not rapidly reduce numbers of inoculated bacteria in the fingernail regions to any greater extent than nonantimicrobial hand washes. Products containing isopropanol or ethanol are very effective in decreasing bacteria in areas around and under the fingernails. PMID:2685028

  4. Four multifaceted countrywide campaigns to promote hand hygiene in Belgian hospitals between 2005 and 2011: impact on compliance to hand hygiene.

    PubMed

    Costers, M; Viseur, N; Catry, B; Simon, A

    2012-05-03

    Four consecutive one-month campaigns were organised to promote hand hygiene in Belgian hospitals between 2005 and 2011. The campaigns included a combination of reminders in wards, educational sessions for healthcare workers, promotion of alcohol-based hand rub use, increasing patient awareness, and audits with performance feedback. Prior and after each one month intervention period, the infection control teams measured hand hygiene compliance of healthcare workers by direct observation using a standardised observation roster. A total of 738,367 opportunities for hand hygiene were observed over the four campaigns. Compliance with hand hygiene significantly increased from 49.6% before to 68.6% after the intervention period for the first, from 53.2% to 69.5% for the second, from 58.0% to 69.1% for the third, and from 62.3% to 72.9% for the fourth campaign. The highest compliance rates were consistently observed in paediatric units. Compliance rates were always markedly lower among physicians than nurses. After patient contact and body fluid exposure risk, compliance rates were noticeably higher than before patient contact and performing aseptic procedures. We conclude that repeated countrywide campaigns to promote hand hygiene result in positive long-term outcomes. However, lower compliance rates among physicians compared with nurses, before patient contact, and before performing aseptic procedures remain challenges for future campaigns.

  5. A general electromagnetic excitation model for electrical machines considering the magnetic saturation and rub impact

    NASA Astrophysics Data System (ADS)

    Xu, Xueping; Han, Qinkai; Chu, Fulei

    2018-03-01

    The electromagnetic vibration of electrical machines with an eccentric rotor has been extensively investigated. However, magnetic saturation was often neglected. Moreover, the rub impact between the rotor and stator is inevitable when the amplitude of the rotor vibration exceeds the air-gap. This paper aims to propose a general electromagnetic excitation model for electrical machines. First, a general model which takes the magnetic saturation and rub impact into consideration is proposed and validated by the finite element method and reference. The dynamic equations of a Jeffcott rotor system with electromagnetic excitation and mass imbalance are presented. Then, the effects of pole-pair number and rubbing parameters on vibration amplitude are studied and approaches restraining the amplitude are put forward. Finally, the influences of mass eccentricity, resultant magnetomotive force (MMF), stiffness coefficient, damping coefficient, contact stiffness and friction coefficient on the stability of the rotor system are investigated through the Floquet theory, respectively. The amplitude jumping phenomenon is observed in a synchronous generator for different pole-pair numbers. The changes of design parameters can alter the stability states of the rotor system and the range of parameter values forms the zone of stability, which lays helpful suggestions for the design and application of the electrical machines.

  6. Effectiveness of liquid soap and hand sanitizer against Norwalk virus on contaminated hands.

    PubMed

    Liu, Pengbo; Yuen, Yvonne; Hsiao, Hui-Mien; Jaykus, Lee-Ann; Moe, Christine

    2010-01-01

    Disinfection is an essential measure for interrupting human norovirus (HuNoV) transmission, but it is difficult to evaluate the efficacy of disinfectants due to the absence of a practicable cell culture system for these viruses. The purpose of this study was to screen sodium hypochlorite and ethanol for efficacy against Norwalk virus (NV) and expand the studies to evaluate the efficacy of antibacterial liquid soap and alcohol-based hand sanitizer for the inactivation of NV on human finger pads. Samples were tested by real-time reverse transcription-quantitative PCR (RT-qPCR) both with and without a prior RNase treatment. In suspension assay, sodium hypochlorite concentrations of >or=160 ppm effectively eliminated RT-qPCR detection signal, while ethanol, regardless of concentration, was relatively ineffective, giving at most a 0.5 log(10) reduction in genomic copies of NV cDNA. Using the American Society for Testing and Materials (ASTM) standard finger pad method and a modification thereof (with rubbing), we observed the greatest reduction in genomic copies of NV cDNA with the antibacterial liquid soap treatment (0.67 to 1.20 log(10) reduction) and water rinse only (0.58 to 1.58 log(10) reduction). The alcohol-based hand sanitizer was relatively ineffective, reducing the genomic copies of NV cDNA by only 0.14 to 0.34 log(10) compared to baseline. Although the concentrations of genomic copies of NV cDNA were consistently lower on finger pad eluates pretreated with RNase compared to those without prior RNase treatment, these differences were not statistically significant. Despite the promise of alcohol-based sanitizers for the control of pathogen transmission, they may be relatively ineffective against the HuNoV, reinforcing the need to develop and evaluate new products against this important group of viruses.

  7. Use of aromatherapy products and increased risk of hand dermatitis in massage therapists.

    PubMed

    Crawford, Glen H; Katz, Kenneth A; Ellis, Elliot; James, William D

    2004-08-01

    To determine the 12-month prevalence of hand dermatitis among massage therapists, to investigate a potential association between hand dermatitis and the use of aromatherapy products, and to study potential associations with other known risk factors for hand dermatitis. Mailed survey. Philadelphia, Pa. Members of a national massage therapy organization who live in the greater Philadelphia region. Self-reported and symptom-based prevalences of hand dermatitis. The number of respondents was 350 (57%). The 12-month prevalence of hand dermatitis in subjects was 15% by self-reported criteria and 23% by a symptom-based method. In multivariate analysis, statistically significant independent risk factors for self-reported hand dermatitis included use of aromatherapy products in massage oils, lotions, or creams (odds ratio, 3.27; 95% confidence interval, 1.53-7.02; P =.002) and history of atopic dermatitis (odds ratio, 8.06; 95% confidence interval, 3.39-19.17; P<.001). The prevalence of hand dermatitis in massage therapists is high. Significant independent risk factors include use of aromatherapy products in massage oils, creams, or lotions and history of atopic dermatitis.

  8. A Reality Rub Crisis Intervention: "I Wish There Was a Law against Belts."

    ERIC Educational Resources Information Center

    Long, Nicholas J.; Techet, Bonnie

    1994-01-01

    Presents Life Space Interview (LSI) or Life Space Crisis Intervention (LSCI) with second-grade student from threatening home environment. Uses Reality Rub Intervention Interview, focusing on five variations: distorted perceptions, tunnel vision, faulty thinking, avoidance, and alibi. Describes incident that led to intervention, interview itself,…

  9. B11 NMR in the layered diborides OsB2 and RuB2

    NASA Astrophysics Data System (ADS)

    Suh, B. J.; Zong, X.; Singh, Y.; Niazi, A.; Johnston, D. C.

    2007-10-01

    B11 nuclear magnetic resonance (NMR) measurements have been performed on B11 enriched OsB2 and RuB2 polycrystalline powder samples in an external field of 4.7T and in the temperature range, 4.2KRuB2 , respectively. The experimental results indicate that a p character dominates the conduction electron wave function at the B site with a negligibly small s character in both compounds.

  10. The effect of the color red on consuming food does not depend on achromatic (Michelson) contrast and extends to rubbing cream on the skin.

    PubMed

    Bruno, Nicola; Martani, Margherita; Corsini, Claudia; Oleari, Claudio

    2013-12-01

    Recent literature suggests that individuals may consume less food when this is served on red plates. We explored this intriguing effect in three experiments. Independent groups of participants were presented with constant amounts of popcorns, chocolate chips, or moisturizing cream, on red, blue, or white plates. They were asked to sample the foods (by tasting them) or the cream (by rubbing it on the hand and forearm) as they wished and to complete mock "sensory analysis" questionnaires. Results confirmed that red plates reduce taste-related consumption and extended this effect to the touch-related consumption of moisturizing cream. Suggesting that the effect was not due to a decrease in the consciously experienced appeal of products on red plates, overall appreciation of the foods or cream did not differ according to plate color. After careful photometric measures of the materials used for each food-plate pairing, we determined that food and cream consumption was not predicted by Michelson (achromatic) contrast. Although the origin of the intriguing effect of the color red on consumption remains unclear, our results may prove useful to future potential explanations. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Healthcare professionals’ hand hygiene knowledge and beliefs in the United Arab Emirates

    PubMed Central

    Ng, Wai Khuan; Shaban, Ramon Z.; van de Mortel, Thea

    2016-01-01

    Background: Hand hygiene at key moments during patient care is considered an important infection prevention and control measure to reduce healthcare-associated infections. While there is extensive research in Western settings, there is little in the United Arab Emirates where particular cultural and religious customs are thought to influence hand hygiene behaviour. Aim: To examine the hand hygiene knowledge and beliefs of health professionals at a tertiary care hospital in the United Arab Emirates. Methods: A mixed methods design employed a survey followed by focus groups with nurses and doctors. Findings: A total of 109 participants (13.6%) completed the survey: 96 nurses (88%) and 13 doctors (12%). Doctors’ hand hygiene knowledge was slightly higher than that of nurses (78.5% versus 73.5%). There was no significant difference in scores on the hand hygiene beliefs scale between nurses (M = 103.06; SD = 8.0) and doctors (M = 99.00; SD = 10.53; t (80) = 1.55; p = 0.13, two-tailed). Seven categories emerged following transcript analysis. Discussion: Hand hygiene knowledge scores suggest further hand hygiene education is required, especially on alcohol-based hand rub use. Addressing doctors’ beliefs is particularly important given the leadership roles that doctors play in healthcare settings. PMID:28989517

  12. Hand washing with soap and water together with behavioural recommendations prevents infections in common work environment: an open cluster-randomized trial.

    PubMed

    Savolainen-Kopra, Carita; Haapakoski, Jaason; Peltola, Piia A; Ziegler, Thedi; Korpela, Terttu; Anttila, Pirjo; Amiryousefi, Ali; Huovinen, Pentti; Huvinen, Markku; Noronen, Heikki; Riikkala, Pia; Roivainen, Merja; Ruutu, Petri; Teirilä, Juha; Vartiainen, Erkki; Hovi, Tapani

    2012-01-16

    Hand hygiene is considered as an important means of infection control. We explored whether guided hand hygiene together with transmission-limiting behaviour reduces infection episodes and lost days of work in a common work environment in an open cluster-randomized 3-arm intervention trial. A total of 21 clusters (683 persons) were randomized to implement hand hygiene with soap and water (257 persons), with alcohol-based hand rub (202 persons), or to serve as a control (224 persons). Participants in both intervention arms also received standardized instructions on how to limit the transmission of infections. The intervention period (16 months) included the emergence of the 2009 influenza pandemic and the subsequent national hand hygiene campaign influencing also the control arm. In the total follow-up period there was a 6.7% reduction of infection episodes in the soap-and water arm (p = 0.04). Before the onset of the anti-pandemic campaign, a statistically significant (p = 0.002) difference in the mean occurrence of infection episodes was observed between the control (6.0 per year) and the soap-and-water arm (5.0 per year) but not between the control and the alcohol-rub arm (5.6 per year). Neither intervention had a decreasing effect on absence from work. We conclude that intensified hand hygiene using water and soap together with behavioural recommendations can reduce the occurrence of self-reported acute illnesses in common work environment. Surprisingly, the occurrence of reported sick leaves also increased in the soap-and water-arm. ClinicalTrials.gov: NCT00981877 The Finnish Work Environment Fund and the National Institute for Health and Welfare.

  13. Brine saturation technique for extraction of light filth from rubbed, ground, and whole sage: collaborative study.

    PubMed

    Freeman, C C

    1985-01-01

    A new approach to the isolation of light filth from the 3 commercial forms of sage was studied collaboratively. It incorporates a simple isopropanol defatting, followed by saturation of the product with brine by alternately heating and cooling, and subsequent trapping of filth from tap water with olive oil. This method circumvents the use of hazardous, expensive solvents and more time-consuming pretreatment procedures. Overall recoveries were 92.1% for rodent hair and 78.7% for insect fragments on clean, easy-to-read papers. An additional blending step was necessary to obtain satisfactory recovery of rodent hair fragments from whole sage. The method has been adopted official first action for light filth in rubbed and ground sage only.

  14. Hand contamination during routine care in medical wards: the role of hand hygiene compliance.

    PubMed

    Monistrol, Olga; López, M Liboria; Riera, Montserrat; Font, Roser; Nicolás, Carme; Escobar, Miguel Angel; Freixas, Núria; Garau, Javier; Calbo, Esther

    2013-04-01

    The hands of healthcare workers (HCWs) are the most common vehicle for the transmission of micro-organisms from patient to patient and within the healthcare environment. The aim of this study was to evaluate the impact of a multimodal campaign on the type and amount of resident and transient flora and the presence of potential risk factors for hand contamination during routine care. A before-after (PRE and POST periods) interventional study was carried out in medical wards of a tertiary care hospital. Eighty-nine samples were analysed. Samples were cultured immediately before patient contact using a glove-juice method. Data collected included socio-demographic and risk factors for hand contamination. Flora was measured as log10 c.f.u. ml(-1) and evaluated by comparing median values in the PRE and POST periods. Transient flora was isolated from the hands of 67.4 and 46.1 % of HCWs in the PRE and POST periods, respectively (P<0.001). Enterobacteriaceae, Pseudomonas spp. and meticillin-sensitive Staphylococcus aureus were the predominant contaminants. Resident flora was isolated from 92.1 % of HCWs in the PRE period and from 70.8 % in the POST period (P<0.001). The meticillin-resistant coagulase-negative staphylococci log10 c.f.u. count ml(-1) decreased from 1.96 ± 1.2 to 0.89 ± 1.2 (mean ± s d; P<0.001), and the global flora count decreased from 2.77 ± 1.1 to 1.56 ± 1.4 (P<0.001). In the POST period, the wearing of fewer rings (P<0.001), shorter fingernail length (P = 0.008), a shorter time since recent hand hygiene (HH) (P = 0.007) and an increased use of alcohol-based hand rub instead of soap (P<0.001) were documented. The HH multimodal strategy reduced the number of risk factors and the level of HCW hand contamination.

  15. Outbreaks where food workers have been implicated in the spread of foodborne disease. Part 10. Alcohol-based antiseptics for hand disinfection and a comparison of their effectiveness with soaps.

    PubMed

    Todd, Ewen C D; Michaels, Barry S; Holah, John; Smith, Debra; Greig, Judy D; Bartleson, Charles A

    2010-11-01

    Alcohol compounds are increasingly used as a substitute for hand washing in health care environments and some public places because these compounds are easy to use and do not require water or hand drying materials. However, the effectiveness of these compounds depends on how much soil (bioburden) is present on the hands. Workers in health care environments and other public places must wash their hands before using antiseptics and/or wearing gloves. However, alcohol-based antiseptics, also called rubs and sanitizers, can be very effective for rapidly destroying some pathogens by the action of the aqueous alcohol solution without the need for water or drying with towels. Alcohol-based compounds seem to be the most effective treatment against gram-negative bacteria on lightly soiled hands, but antimicrobial soaps are as good or better when hands are more heavily contaminated. Instant sanitizers have no residual effect, unlike some antimicrobial soaps that retain antimicrobial activity after the hygienic action has been completed, e.g., after hand washing. Many alcohol-based hand rubs have antimicrobial agents added to them, but each formulation must be evaluated against the target pathogens in the environment of concern before being considered for use. Wipes also are widely used for quick cleanups of hands, other body parts, and surfaces. These wipes often contain alcohol and/or antimicrobial compounds and are used for personal hygiene where water is limited. However, antiseptics and wipes are not panaceas for every situation and are less effective in the presence of more than a light soil load and against most enteric viruses.

  16. Ex vivo skin absorption of terpenes from Vicks VapoRub ointment.

    PubMed

    Cal, Krzysztof; Sopala, Monika

    2008-08-01

    The pharmaceutical market offers a wide range of inhalant drug products applied on the skin that contain essential oils and/or their isolated compounds, i.e. terpenes. Because there are few data concerning the skin penetration of terpenes, especially from complex carriers, the goal of this study was to determine the ex vivo skin absorption kinetics of chosen terpenes, namely eucalyptol, menthol, camphor, alpha-pinene, and beta-pinene, from the product Vicks VapoRub. Human cadaver skin was placed in a flow-through diffusion chamber and the product was applied for 15, 30, and 60 min. After the application time the skin was separated into layers using a tape-stripping technique: three fractions of stratum corneum and epidermis with dermis, and terpenes amounts in the samples were determined by gas-chromatography. The investigated terpenes showed different absorption characteristics related to their physicochemical properties and did not permeate through the skin into the acceptor fluid. Eucalyptol had the largest total accumulation in the stratum corneum and in the epidermis with dermis, while alpha-pinene penetrated into the skin in the smallest amount. The short time in which saturation of the stratum corneum with the terpenes occurred and the high accumulation of most of the investigated terpenes in the skin layers proved that these compounds easily penetrate and permeate the stratum corneum and that in vivo they may easily penetrate into the blood circulation.

  17. A quasi-experimental study to determine the effects of a multifaceted educational intervention on hand hygiene compliance in a radiography unit.

    PubMed

    O'Donoghue, Margaret; Ng, Suk-Hing; Suen, Lorna Kp; Boost, Maureen

    2016-01-01

    Whilst numerous studies have investigated nurses' compliance with hand hygiene and use of alcohol-based hand rub (ABHR), limited attention has been paid to these issues in allied health staff. Reports have linked infections to breaches in infection control in the radiography unit (RU). With advances in medical imaging, a higher proportion of patients come into contact with RU staff increasing the need for good hand hygiene compliance. This study aimed to evaluate effectiveness on compliance of an intervention to improve awareness of hand hygiene in the RU of a district hospital. A quasi-experimental study design including questionnaires assessing knowledge and attitudes of hand hygiene and direct observation of participants was used to evaluate an educational programme on hand hygiene of the RU of a large district hospital. All healthcare workers (HCW), comprising 76 radiographers, 17 nurses, and nine healthcare assistants (HCA), agreed to participate in the study. Of these, 85 completed the initial and 76 the post-test anonymous questionnaire. The hand hygiene compliance of all 102 HCW was observed over a 3-week period prior to and after the intervention. The 2-month intervention consisted of talks on hand hygiene and benefits of ABHR, provision of visual aids, wall-mounted ABHR dispensers, and personal bottles of ABHR. Before the intervention, overall hand hygiene compliance was low (28.9 %). Post-intervention, compliance with hand hygiene increased to 51.4 %. This improvement was significant for radiographers and HCA. Additionally, knowledge and attitudes improved in particular, understanding that ABHR can largely replace handwashing and there is a need to perform hand hygiene after environmental contact. The increased use of ABHR allowed HCW to feel they had enough time to perform hand hygiene. The educational intervention led to increased awareness of hand hygiene opportunities and better acceptance of ABHR use. The reduced time needed to perform hand

  18. Numerical results of the influence of thermal effects on the turbo machine rotordynamics induced by light-rubs against a brush seal

    NASA Astrophysics Data System (ADS)

    Fay, R.; Kreuzer, D.; Liebich, R.; Wiedemann, T.; Werner, S.

    2018-07-01

    Brush seals are an efficient alternative for labyrinth seals in turbomachinery. Brush seals show on the one hand a better leakage reduction in relation to their axial length and hence allow a shorter design of the machinery. On the other hand, the particularly small gap between bristles and the engine shaft increases the risk of rotor-stator-contact. The flexible brush seals induces basically light-rubs that in some cases might lead to spiral vibrations and thermal mechanical instabilities. Spiral vibrations are caused by a thermal deflection of the rotor induced by a heat flow into the shaft. To predict areas of instabilites during the design process a tool was developed at the Berlin Institute of Technology. The model combines a rotor dynamic model and a thermal model. The thermal system is reduced using a stationary solution, so that the final system, on which the stability analysis is performed, is comparable to the established Kellenberger model. The paper presents the numerical model for the predictions of unstable regions depending on rotational speed. This is illustrated by means of an example of an axial compressor manufactured by MAN Diesel & Turbo.

  19. [A multimodal strategy to improve adherence to hand hygiene in a university hospital].

    PubMed

    Fariñas-Alvarez, C; Portal-María, T; Flor-Morales, V; Aja-Herrero, A; Fabo-Navarro, M; Lanza-Marín, S; Lobeira-Rubio, R; Polo-Hernández, N; Sixto-Montero, M; Moreta-Sánchez, R; Ballesteros-Sanz, M Á; Yañez-San Segundo, L; Bartalome-Pacheco, M J; Armiñanzas-Castillo, C

    Within the framework of the PaSQ (Patient Safety and Quality care) Project, this hospital decided to implement a multifaceted hospital-wide Hand Hygiene (HH) intervention based on a multimodal WHO approach over one year, focusing on achieving a sustained change in HH cultural change in this hospital. Setting: University Hospital Marqués de Valdecilla, Santander (Spain), a tertiary hospital with 900 beds. Intervention period: 2014. An action plan was developed that included the implementation of activities in each component of the 5-step multimodal intervention. An observation/feedback methodology was used that included the provision of performance and results feedback to the staff. A 3/3 strategy (non-blinded direct observation audits performed during 3 randomised days every 3 weeks with pro-active corrective actions at the end of each observation period). HH compliance, alcohol-based hand-rub (ABHR) consumption, and rate of MRSA infection, were monitored during the intervention. Hospital ABHR consumption increased during the study period: from 17.5 to 19.7mL/patient-days. In the intervention units, this consumption was 24.8mL pre-intervention, 42.5mL during the intervention, and 30.4mL two months post-intervention. There were 137 evaluation periods in 30 different days, in which a total of 737 health-care workers were observed and 1,870 HH opportunities. HH compliance was 54.5%, ranging between 44.8% and 69.9%. The incidence of MRSA infection decreased during the intervention in the selected units, from 13.2 infections per 10,000 patient-days pre-intervention to 5.7 three months post-intervention. Our HH strategy, supported by a 3/3 strategy increased alcohol-based hand-rub consumption and compliance. A reduction in MRSA infections was observed. Copyright © 2016 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Hand washing with soap and water together with behavioural recommendations prevents infections in common work environment: an open cluster-randomized trial

    PubMed Central

    2012-01-01

    Background Hand hygiene is considered as an important means of infection control. We explored whether guided hand hygiene together with transmission-limiting behaviour reduces infection episodes and lost days of work in a common work environment in an open cluster-randomized 3-arm intervention trial. Methods A total of 21 clusters (683 persons) were randomized to implement hand hygiene with soap and water (257 persons), with alcohol-based hand rub (202 persons), or to serve as a control (224 persons). Participants in both intervention arms also received standardized instructions on how to limit the transmission of infections. The intervention period (16 months) included the emergence of the 2009 influenza pandemic and the subsequent national hand hygiene campaign influencing also the control arm. Results In the total follow-up period there was a 6.7% reduction of infection episodes in the soap-and water arm (p = 0.04). Before the onset of the anti-pandemic campaign, a statistically significant (p = 0.002) difference in the mean occurrence of infection episodes was observed between the control (6.0 per year) and the soap-and-water arm (5.0 per year) but not between the control and the alcohol-rub arm (5.6 per year). Neither intervention had a decreasing effect on absence from work. Conclusions We conclude that intensified hand hygiene using water and soap together with behavioural recommendations can reduce the occurrence of self-reported acute illnesses in common work environment. Surprisingly, the occurrence of reported sick leaves also increased in the soap-and water-arm. Trial Registration ClinicalTrials.gov: NCT00981877 Source of funding The Finnish Work Environment Fund and the National Institute for Health and Welfare. PMID:22243622

  1. Replication of Holograms with Corn Syrup by Rubbing

    PubMed Central

    Mejias-Brizuela, Nildia Y.; Olivares-Pérez, Arturo; Ortiz-Gutiérrez, Mauricio

    2012-01-01

    Corn syrup films are used to replicate holograms in order to fabricate micro-structural patterns without the toxins commonly found in photosensitive salts and dyes. We use amplitude and relief masks with lithographic techniques and rubbing techniques in order to transfer holographic information to corn syrup material. Holographic diffraction patterns from holographic gratings and computer Fourier holograms fabricated with corn syrup are shown. We measured the diffraction efficiency parameter in order to characterize the film. The versatility of this material for storage information is promising. Holographic gratings achieved a diffraction efficiency of around 8.4% with an amplitude mask and 36% for a relief mask technique. Preliminary results using corn syrup as an emulsion for replicating holograms are also shown in this work.

  2. Pointing and pantomime in wild apes? Female bonobos use referential and iconic gestures to request genito-genital rubbing

    PubMed Central

    Douglas, Pamela Heidi; Moscovice, Liza R.

    2015-01-01

    Referential and iconic gesturing provide a means to flexibly and intentionally share information about specific entities, locations, or goals. The extent to which nonhuman primates use such gestures is therefore of special interest for understanding the evolution of human language. Here, we describe novel observations of wild female bonobos (Pan paniscus) using referential and potentially iconic gestures to initiate genito-genital (GG) rubbing, which serves important functions in reducing social tension and facilitating cooperation. We collected data from a habituated community of bonobos at Luikotale, DRC, and analysed n = 138 independent gesture bouts made by n = 11 females. Gestures were coded in real time or from video. In addition to meeting the criteria for intentionality, in form and function these gestures resemble pointing and pantomime–two hallmarks of human communication–in the ways in which they indicated the relevant body part or action involved in the goal of GG rubbing. Moreover, the gestures led to GG rubbing in 83.3% of gesture bouts, which in turn increased tolerance in feeding contexts between the participants. We discuss how biologically relevant contexts in which individuals are motivated to cooperate may facilitate the emergence of language precursors to enhance communication in wild apes. PMID:26358661

  3. 75 FR 27504 - Substantial Product Hazard List: Hand-Held Hair Dryers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-17

    ...The Consumer Product Safety Improvement Act of 2008 (``CPSIA''), authorizes the United States Consumer Product Safety Commission (``Commission'') to specify, by rule, for any consumer product or class of consumer products, characteristics whose existence or absence shall be deemed a substantial product hazard under certain circumstances. In this document, the Commission is proposing a rule to determine that any hand-held hair dryer without integral immersion protection presents a substantial product hazard.

  4. Using the six sigma process to implement the Centers for Disease Control and Prevention Guideline for Hand Hygiene in 4 intensive care units.

    PubMed

    Eldridge, Noel E; Woods, Susan S; Bonello, Robert S; Clutter, Kay; Ellingson, Leann; Harris, Mary Ann; Livingston, Barbara K; Bagian, James P; Danko, Linda H; Dunn, Edward J; Parlier, Renee L; Pederson, Cheryl; Reichling, Kim J; Roselle, Gary A; Wright, Steven M

    2006-02-01

    The Centers for Disease Control and Prevention (CDC) Guideline for Hand Hygiene in Health Care Settings was issued in 2002. In 2003, the Joint Commission on Accreditation of Healthcare Organizations (JCAHO) established complying with the CDC Guideline as a National Patient Safety Goal for 2004. This goal has been maintained through 2006. The CDC's emphasis on the use of alcohol-based hand rubs (ABHRs) rather than soap and water was an opportunity to improve compliance, but the Guideline contained over 40 specific recommendations to implement. To use the Six Sigma process to examine hand hygiene practices and increase compliance with the CDC hand hygiene recommendations required by JCAHO. Six Sigma Project with pre-post design. Physicians, nurses, and other staff working in 4 intensive care units at 3 hospitals. Observed compliance with 10 required hand hygiene practices, mass of ABHR used per month per 100 patient-days, and staff attitudes and perceptions regarding hand hygiene reported by questionnaire. Observed compliance increased from 47% to 80%, based on over 4,000 total observations. The mass of ABHR used per 100 patient-days in 3 intensive care units (ICUs) increased by 97%, 94%, and 70%; increases were sustained for 9 months. Self-reported compliance using the questionnaire did not change. Staff reported increased use of ABHR and increased satisfaction with hand hygiene practices and products. The Six Sigma process was effective for organizing the knowledge, opinions, and actions of a group of professionals to implement the CDC's evidence-based hand hygiene practices in 4 ICUs. Several tools were developed for widespread use.

  5. Adherence to hand hygiene protocol by clinicians and medical students at Queen Elizabeth Central Hospital, Blantyre-Malawi.

    PubMed

    Kalata, N L; Kamange, L; Muula, A S

    2013-06-01

    , with forgetfulness and negligence being the major contributing factors. A hospital-wide multifaceted program aiming at clinicians and students education, adoption of alcohol based hand rubs as a primary formulation, production of colored poster reminders and encouraging role modeling of junior practitioners by senior practitioners can help improve compliance to hand hygiene.

  6. Texture Rubbings

    ERIC Educational Resources Information Center

    Szekely, George

    2011-01-01

    As hands-on environmental observers, children use printing to save and share "treasures" they find. In this article, the author shares thoughts which are based on observing what children find valuable and worth saving, and the printmaking processes used to "lift" images from their finds.

  7. Hand hygiene with soap and water is superior to alcohol rub and antiseptic wipes for removal of Clostridium difficile.

    PubMed

    Oughton, Matthew T; Loo, Vivian G; Dendukuri, Nandini; Fenn, Susan; Libman, Michael D

    2009-10-01

    To evaluate common hand hygiene methods for efficacy in removing Clostridium difficile. Randomized crossover comparison among 10 volunteers with hands experimentally contaminated by nontoxigenic C. difficile. Interventions included warm water with plain soap, cold water with plain soap, warm water with antibacterial soap, antiseptic hand wipes, alcohol-based handrub, and a control involving no intervention. All interventions were evaluated for mean reduction in colony-forming units (CFUs) under 2 contamination protocols: "whole hand" and "palmar surface." Results were analyzed according to a Bayesian approach, by using hierarchical models adjusted for multiple observations. Under the whole-hand protocol, the greatest adjusted mean reductions were achieved by warm water with plain soap (2.14 log(10) CFU/mL [95% credible interval (CrI), 1.74-2.54 log(10) CFU/mL]), cold water with plain soap (1.88 log(10) CFU/mL [95% CrI, 1.48-2.28 log(10) CFU/mL), and warm water with antibacterial soap (1.51 log(10) CFU/mL [95% CrI, 1.12-1.91 log(10) CFU/mL]), followed by antiseptic hand wipes (0.57 log(10) CFU/mL [95% CrI, 0.17-0.96 log(10) CFU/mL]). Alcohol-based handrub (0.06 log(10) CFU/mL [95% CrI, -0.34 to 0.45 log(10) CFU/mL]) was equivalent to no intervention. Under the palmar surface protocol, warm water with plain soap, cold water with plain soap, and warm water with antibacterial soap again yielded the greatest mean reductions, followed by antiseptic hand wipes (26.6, 26.6, 26.6, and 21.9 CFUs per plate, respectively), when compared with alcohol-based handrub. Hypothenar (odds ratio, 10.98 [95% CrI, 1.96-37.65]) and thenar (odds ratio, 6.99 [95% CrI, 1.25-23.41]) surfaces were more likely than fingertips to remain heavily contaminated after handwashing. Handwashing with soap and water showed the greatest efficacy in removing C. difficile and should be performed preferentially over the use of alcohol-based handrubs when contact with C. difficile is suspected or likely.

  8. Hand hygiene compliance in transplant and other special patient groups: an observational study.

    PubMed

    Graf, Karolin; Ott, Ella; Wolny, Michael; Tramp, Nadine; Vonberg, Ralf-Peter; Haverich, Axel; Chaberny, Iris Freya

    2013-06-01

    This study evaluates hand hygiene behavior of health care workers in a German university hospital stratified for treatment of special patient groups (eg, transplant patients). From 2008 to 2010, comprehensive education and training of all health care workers was implemented to improve hand hygiene compliance. Consumption rates of alcohol-based hand rub and gloves were collected and evaluated. Of the 5,647 opportunities of hand disinfection evaluated, 1,607 occurred during care for transplant patients. To our knowledge, this is the largest survey of hand hygiene compliance in special patient groups on intensive care units in a university hospital in Germany. Health care workers on surgical intensive care units showed lower hand hygiene compliance compared with health care workers on other types of intensive care units. Compliance toward hand hygiene was significantly higher on hemato-oncologic and pediatric wards. In general, hand disinfection was performed significantly more frequently after an intervention than before (P < .05, 95% confidence interval: 1.24-1.84). Overall, there was no significant difference in hand hygiene compliance when caring for transplant patients or other patients (odds ratio, 1.16; 95% confidence interval: 0.95-1.42). Nurse's and physician's hand hygiene compliance improved because of education. Hand hygiene compliance is not increased in the care for transplant patients (despite their predisposition for nosocomial infections) compared with other patients. Additional studies will be necessary to further investigate these findings. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  9. Preference and compliance of waterless hand-hygiene products versus soap and water.

    PubMed

    Carr, Michele P; Sullivan, Stefanie; Gilmore, Jenny; Rashid, Robert G

    2003-09-01

    To compare handwashing using traditional antimicrobial soap and water with two antimicrobial waterless hand-hygiene products for personal preference and compliance. Fifty dental and dental hygiene students were randomly chosen to participate in the study. All subjects were anonymously observed prior to the introduction of the waterless products for handwashing compliance using soap and water for 1 week. All subjects were then instructed on the use of a waterless gel and foam for handwashing. Both waterless products were used for a period of 1 week and students again were anonymously observed. A questionnaire was distributed at the conclusion of the study to determine product preference. During handwashing with soap and water, the average time the soap was in contact with the hands was 7.0 seconds. The average contact time with the gel and foam was 15.3 seconds and 20.0 seconds, respectfully. Questionnaire results indicated that the foam was significantly preferred over the gel and soap and water (54%, 28% and 16%, respectively). The foam was also significantly preferred when evaluating fragrance (52%), kindness to the skin (66%), convenience (64%) and fastest drying time (54%). Results from this study indicate that the waterless foam product was significantly preferred over the waterless gel and traditional soap and water for handwashing procedures. Since handwashing guidelines, regardless of which product used, recommend a minimum of 15 seconds to minimize the number of transient microorganisms on the hands, compliance was found only with the foam and the gel.

  10. Rubbing skin with nylon towels as a major cause of pseudomonas folliculitis in a Japanese population.

    PubMed

    Teraki, Yuichi; Nakamura, Kaori

    2015-01-01

    Pseudomonas folliculitis (PF) is a community-acquired skin infection, which develops after exposure to contaminated water such as whirlpools, swimming pools, water slides and hot tubs. In Japan, this condition has been sporadically reported, often in association with bathing; however, the exact cause of PF in the Japanese population remains unclear. In this study, we retrospectively reviewed 10 patients with PF diagnosed at our dermatology clinic (two males and eight females). Four patients had recurrences over 1-3 years. Notably, eight of the 10 patients were rubbing their bodies with nylon towels or sponges placed in the bathrooms during bathing. Pseudomonas aeruginosa was isolated from the nylon towels used in two of the two patients examined. Discontinued use of nylon towels resulted in prompt resolution of PF and no recurrence in all cases. Our observation suggests that rubbing the skin with nylon towels contaminated with P. aeruginosa was a major cause of PF in a Japanese population. © 2014 Japanese Dermatological Association.

  11. Investigations on bending-torsional vibrations of rotor during rotor-stator rub using Lagrange multiplier method

    NASA Astrophysics Data System (ADS)

    Mokhtar, Md Asjad; Kamalakar Darpe, Ashish; Gupta, Kshitij

    2017-08-01

    The ever-increasing need of highly efficient rotating machinery causes reduction in the clearance between rotating and non-rotating parts and increase in the chances of interaction between these parts. The rotor-stator contact, known as rub, has always been recognized as one of the potential causes of rotor system malfunctions and a source of secondary failures. It is one of few causes that influence both lateral and torsional vibrations. In this paper, the rotor stator interaction phenomenon is investigated in the finite element framework using Lagrange multiplier based contact mechanics approach. The stator is modelled as a beam that can respond to axial penetration and lateral friction force during the contact with the rotor. It ensures dynamic stator contact boundary and more realistic contact conditions in contrast to most of the earlier approaches. The rotor bending-torsional mode coupling during contact is considered and the vibration response in bending and torsion are analysed. The effect of parameters such as clearance, friction coefficient and stator stiffness are studied at various operating speeds and it has been found that certain parameter values generate peculiar rub related features. Presence of sub-harmonics in the lateral vibration frequency spectra are prominently observed when the rotor operates near the integer multiple of its lateral critical speed. The spectrum cascade of torsional vibration shows the presence of bending critical speed along with the larger amplitudes of frequencies close to torsional natural frequency of the rotor. When m × 1/n X frequency component of rotational frequency comes closer to the torsional natural frequency, stronger torsional vibration amplitude is noticed in the spectrum cascade. The combined information from the stator vibration and rotor lateral-torsional vibration spectral features is proposed for robust rub identification.

  12. Room temperature rubbing for few-layer two-dimensional thin flakes directly on flexible polymer substrates

    PubMed Central

    Yu, Yan; Jiang, Shenglin; Zhou, Wenli; Miao, Xiangshui; Zeng, Yike; Zhang, Guangzu; Liu, Sisi

    2013-01-01

    The functional layers of few-layer two-dimensional (2-D) thin flakes on flexible polymers for stretchable applications have attracted much interest. However, most fabrication methods are “indirect” processes that require transfer steps. Moreover, previously reported “transfer-free” methods are only suitable for graphene and not for other few-layer 2-D thin flakes. Here, a friction based room temperature rubbing method is proposed for fabricating different types of few-layer 2-D thin flakes (graphene, hexagonal boron nitride (h-BN), molybdenum disulphide (MoS2), and tungsten disulphide (WS2)) on flexible polymer substrates. Commercial 2-D raw materials (graphite, h-BN, MoS2, and WS2) that contain thousands of atom layers were used. After several minutes, different types of few-layer 2-D thin flakes were fabricated directly on the flexible polymer substrates by rubbing procedures at room temperature and without any transfer step. These few-layer 2-D thin flakes strongly adhere to the flexible polymer substrates. This strong adhesion is beneficial for future applications. PMID:24045289

  13. Comparison between Rinse and Crush-and-Rub Sampling for Aerobic Bacteria Recovery from Hatching Eggs after Sanitization

    USDA-ARS?s Scientific Manuscript database

    This study compared surface and deep eggshell aerobic bacteria recovered by rinse and crush-and-rub sampling methods for commercial hatching eggs after treatments with sanitizers. Eggs were arranged into 5 treatments consisting of three sanitizers, Water, and No-treatment. Sanitizers were Hydrogen...

  14. Gasoline on hands: preliminary study on collection and persistence.

    PubMed

    Darrer, Melinda; Jacquemet-Papilloud, Joëlle; Delémont, Olivier

    2008-03-05

    The identification of an arsonist remains one of the most difficult challenges a fire investigation has to face. Seeking and detection of traces of gasoline could provide a valuable information to link a suspect with an arson scene where gasoline was used to set-up the fire. In this perspective, a first study was undertaken to evaluate a simple, fast and efficient method for collecting gasoline from hands, and to assess its persistence over time. Four collection means were tested: PVC, PE and Latex gloves, as well as humidified filter paper. A statistical assessment of the results indicates that Latex and PVC gloves worn for about 20 min, as well as paper filter rubbed on hands, allow an efficient collection of gasoline applied to hands. Due to ease of manipulation and to a reduced amount of volatile compounds detected from the matrix, PVC gloves were selected for the second set of experiments. The evaluation of the persistence of gasoline on hands was then carried out using two initial quantities (500 and 1000 microl). Collection was made with PVC gloves after 0, 30 min, 1, 2 and 4h, on different volunteers. The results show a common tendency of massive evaporation of gasoline during the first 30 min: a continued but non-linear decrease was observed along different time intervals. The results of this preliminary study are in agreement with other previous researches conducted on the detection of flammable liquid residues on clothes, shoes and skin.

  15. Development of an observational measure of healthcare worker hand-hygiene behaviour: the hand-hygiene observation tool (HHOT).

    PubMed

    McAteer, J; Stone, S; Fuller, C; Charlett, A; Cookson, B; Slade, R; Michie, S

    2008-03-01

    Previous observational measures of healthcare worker (HCW) hand-hygiene behaviour (HHB) fail to provide adequate standard operating procedures (SOPs), accounts of inter-rater agreement testing or evidence of sensitivity to change. This study reports the development of an observational tool in a way that addresses these deficiencies. Observational categories were developed systematically, guided by a clinical guideline, previous measures and pilot hand-hygiene behaviour observations (HHOs). The measure, a simpler version of the Geneva tool, consists of HHOs (before and after low-risk, high-risk or unobserved contact), HHBs (soap, alcohol hand rub, no action, unknown), and type of HCW. Inter-observer agreement for each category was assessed by observation of 298 HHOs and HHBs by two independent observers on acute elderly and intensive care units. Raw agreement (%) and Kappa were 77% and 0.68 for HHB; 83% and 0.77 for HHO; and 90% and 0.77 for HCW. Inter-observer agreement for overall compliance of a group of HCWs was assessed by observation of 1191 HHOs and HHBs by two pairs of independent observers. Overall agreement was good (intraclass correlation coefficient = 0.79). Sensitivity to change was examined by autoregressive time-series modelling of longitudinal observations for 8 months on the intensive therapy unit during an Acinetobacter baumannii outbreak and subsequent strengthening of infection control measures. Sensitivity to change was demonstrated by a rise in compliance from 80 to 98% with an odds ratio of increased compliance of 7.00 (95% confidence interval: 4.02-12.2) P < 0.001.

  16. Impact of a multi-faceted training intervention on the improvement of hand hygiene and gloving practices in four healthcare settings including nursing homes, acute-care geriatric wards and physical rehabilitation units.

    PubMed

    Eveillard, Matthieu; Raymond, Françoise; Guilloteau, Véronique; Pradelle, Marie-Thérèse; Kempf, Marie; Zilli-Dewaele, Marina; Joly-Guillou, Marie-Laure; Brunel, Patrick

    2011-10-01

    To assess the impact of a multi-faceted training program on the compliance with hand hygiene and gloving practices. Hand hygiene is considered as the cornerstone of the prevention of hospital-acquired infections. Several studies have enhanced the poor effectiveness of training programs in improving hand hygiene compliance. A before-after evaluation study. The study was conducted in four healthcare settings before and after an intervention program which included the performance feedback of the first evaluation phase, three six-h training sessions, the assessment of hand hygiene performance with teaching boxes and the organisation of one full-day session devoted to institutional communication around hand hygiene in each setting. Hand hygiene compliance and quality of hand rubbing were evaluated. Hand hygiene opportunities were differentiated into extra-series opportunities (before or after a single contact and before the first contact or after the last contact of a series of consecutive contacts) and intra-series opportunities (from the opportunity following the first contact to the opportunity preceding the last in the same series). Overall, 969 contacts corresponding to 1,470 hand hygiene opportunities (760 during the first phase and 710 during the second) were observed. A significant improvement of observed practices was recorded for the hand hygiene compliance in intra-series opportunities (39·0% vs. 19·0%; p < 10(-5) ), the proportion of gloves worn if indicated (71·4% vs. 52·0%; p < 0·001) and the quality of hand rubbing (85·0% vs. 71·9%; p < 10(-5) ). Some of the performances measured for both hand hygiene and gloving practices were improved. We plan to extend this investigation by performing a qualitative study with experts in behavioural sciences to try improving practices for which adherence was still weak after the training program such as hand hygiene in intra-series opportunities. This study underscored the usefulness of implementing

  17. Using the Six Sigma Process to Implement the Centers for Disease Control and Prevention Guideline for Hand Hygiene in 4 Intensive Care Units

    PubMed Central

    Eldridge, Noel E; Woods, Susan S; Bonello, Robert S; Clutter, Kay; Ellingson, LeAnn; Harris, Mary Ann; Livingston, Barbara K; Bagian, James P; Danko, Linda H; Dunn, Edward J; Parlier, Renee L; Pederson, Cheryl; Reichling, Kim J; Roselle, Gary A; Wright, Steven M

    2006-01-01

    BACKGROUND The Centers for Disease Control and Prevention (CDC) Guideline for Hand Hygiene in Health Care Settings was issued in 2002. In 2003, the Joint Commission on Accreditation of Healthcare Organizations (JCAHO) established complying with the CDC Guideline as a National Patient Safety Goal for 2004. This goal has been maintained through 2006. The CDC's emphasis on the use of alcohol-based hand rubs (ABHRs) rather than soap and water was an opportunity to improve compliance, but the Guideline contained over 40 specific recommendations to implement. OBJECTIVE To use the Six Sigma process to examine hand hygiene practices and increase compliance with the CDC hand hygiene recommendations required by JCAHO. DESIGN Six Sigma Project with pre-post design. PARTICIPANTS Physicians, nurses, and other staff working in 4 intensive care units at 3 hospitals. MEASUREMENTS Observed compliance with 10 required hand hygiene practices, mass of ABHR used per month per 100 patient-days, and staff attitudes and perceptions regarding hand hygiene reported by questionnaire. RESULTS Observed compliance increased from 47% to 80%, based on over 4,000 total observations. The mass of ABHR used per 100 patient-days in 3 intensive care units (ICUs) increased by 97%, 94%, and 70%; increases were sustained for 9 months. Self-reported compliance using the questionnaire did not change. Staff reported increased use of ABHR and increased satisfaction with hand hygiene practices and products. CONCLUSIONS The Six Sigma process was effective for organizing the knowledge, opinions, and actions of a group of professionals to implement the CDC's evidence-based hand hygiene practices in 4 ICUs. Several tools were developed for widespread use. PMID:16637959

  18. Costing the Australian National Hand Hygiene Initiative.

    PubMed

    Page, K; Barnett, A G; Campbell, M; Brain, D; Martin, E; Fulop, N; Graves, N

    2014-11-01

    The Australian National Hand Hygiene Initiative (NHHI) is a major patient safety programme co-ordinated by Hand Hygiene Australia (HHA) and funded by the Australian Commission for Safety and Quality in Health Care. The annual costs of running this programme need to be understood to know the cost-effectiveness of a decision to sustain it as part of health services. To estimate the annual health services cost of running the NHHI; the set-up costs are excluded. A health services perspective was adopted for the costing and collected data from the 50 largest public hospitals in Australia that implemented the initiative, covering all states and territories. The costs of HHA, the costs to the state-level infection-prevention groups, the costs incurred by each acute hospital, and the costs for additional alcohol-based hand rub are all included. The programme cost AU$5.56 million each year (US$5.76, £3.63 million). Most of the cost is incurred at the hospital level (65%) and arose from the extra time taken for auditing hand hygiene compliance and doing education and training. On average, each infection control practitioner spent 5h per week on the NHHI, and the running cost per annum to their hospital was approximately AU$120,000 in 2012 (US$124,000, £78,000). Good estimates of the total costs of this programme are fundamental to understanding the cost-effectiveness of implementing the NHHI. This paper reports transparent costing methods, and the results include their uncertainty. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  19. Conspicuous vs customary location of hand hygiene agent dispensers on alcohol-based hand hygiene product usage in an intensive care unit.

    PubMed

    Thomas, Bruce W; Berg-Copas, Gina M; Vasquez, Donald G; Jackson, Brandy L; Wetta-Hall, Ruth

    2009-05-01

    Hand washing is considered the single most important nosocomial infection-control strategy, yet compliance rarely meets levels recommended by infection control authorities. To determine whether placement of hand hygiene foam dispensers in more conspicuous positions and closer proximity to patients would increase use of infection control agents as measured by volume of product used. Further, to ascertain the influence of dispenser placement vs the number of dispensers available on usage by volume. This prospective, observational study conducted in an intensive care unit was composed of three observation periods. A control period with standard agent dispenser location (8 dispensers) was followed by two experimental periods: (1) "conspicuous and immediate proximity to patient" placement (16 dispensers) and (2) standard locations with a dramatic increase in the number of dispensers (36 dispensers). Volume of use for alcohol-based hand hygiene agent during the three observation periods revealed a statistically significant increase in daily consumption after conspicuous and proximate positioning of dispensers (P<.001). However, increasing the number of dispensers did not increase agent use (P=.196). More conspicuous placement of dispensers containing alcohol-based hand hygiene agent (ie, immediate proximity to patients) resulted in statistically and clinically significant increases in product usage. An increase in the number of dispensers did not increase usage. The impact of dispenser positioning on usage by volume for these highly effective products should be considered when planning and implementing intensive care unit infection-control policies.

  20. Microwave-superheated Vics Vapo Rub: an ocular public health danger.

    PubMed

    Fung, Anne E; Oxford, Karen W

    2004-02-01

    To report a case of a microwave-oven superheated petroleum-based liquid causing severe chemical and thermal ocular burns treated successfully with amniotic membrane transplantation. Observational case report. Retrospective review of clinical case. A 77-year-old woman sustained a severe combined chemical and thermal burn from microwave-heated Vicks Vapo-Rub requiring amniotic membrane transplant, with subsequent development of phacomorphic glaucoma, requiring cataract extraction, and bullous keratopathy, requiring penetrating keratoplasty. As microwave oven use becomes more commonplace, the risk of superheating liquids becomes an increasingly significant ocular danger. Continued efforts to educate the public about safe microwave use is necessary. Additionally, amniotic membrane transplantation was found to be effective in managing a combined chemical and thermal ocular burn.

  1. Point of care hand hygiene-where's the rub? A survey of US and Canadian health care workers' knowledge, attitudes, and practices.

    PubMed

    Kirk, Jane; Kendall, Anson; Marx, James F; Pincock, Ted; Young, Elizabeth; Hughes, Jillian M; Landers, Timothy

    2016-10-01

    Hand hygiene at the point of care is recognized as a best practice for promoting compliance at the moments when hand hygiene is most critical. The objective of this study was to compare knowledge, attitudes, and practices of US and Canadian frontline health care personnel regarding hand hygiene at the point of care. Physicians and nurses in US and Canadian hospitals were invited to complete a 32-question online survey based on evidence supporting point of care hand hygiene. Eligible health care personnel were in direct clinical practice at least 50% of the time. Three hundred fifty frontline caregivers completed the survey. Among respondents, 57.1% were from the United States and 42.9% were from Canada. Respondents were evenly distributed between physician and nurses. The US and Canadian respondents gave identical ranking to their perceived barriers to hand hygiene compliance. More than half of the respondents from both the United States and Canada agreed or strongly agreed that they would be more likely to clean their hands when recommended if alcohol-based handrub was closer to the patient. This survey demonstrates that similarities between Canada and the United States were more common than not, and the survey raises, or suggests, potential knowledge gaps that require further illumination. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. Single crystalline growth of a soluble organic semiconductor in a parallel aligned liquid crystal solvent using rubbing-treated polyimide films

    NASA Astrophysics Data System (ADS)

    Matsuzaki, Tomoya; Shibata, Yosei; Takeda, Risa; Ishinabe, Takahiro; Fujikake, Hideo

    2017-01-01

    For directional control of organic single crystals, we propose a crystal growth method using liquid crystal as the solvent. In this study, we examined the formation of 2,7-dioctyl[1]benzothieno[3,2-b][1]benzothiophene (C8-BTBT) single crystals using a parallel aligned liquid crystal (LC) cell and rubbing-treated polyimide films in order to clarify the effects of LC alignment on anisotropic C8-BTBT crystal growth. Based on the results, we found that the crystal growth direction of C8-BTBT single crystals was related to the direction of the aligned LC molecules because of rubbing treatment. Moreover, by optical evaluation, we found that the C8-BTBT single crystals have a aligned molecular structure.

  3. Changing the paradigm: messages for hand hygiene education and audit from cluster analysis.

    PubMed

    Gould, D J; Navaie, D; Purssell, E; Drey, N S; Creedon, S

    2018-04-01

    Hand hygiene is considered to be the foremost infection prevention measure. How healthcare workers accept and make sense of the hand hygiene message is likely to contribute to the success and sustainability of initiatives to improve performance, which is often poor. A survey of nurses in critical care units in three National Health Service trusts in England was undertaken to explore opinions about hand hygiene, use of alcohol hand rubs, audit with performance feedback, and other key hand-hygiene-related issues. Data were analysed descriptively and subjected to cluster analysis. Three main clusters of opinion were visualized, each forming a significant group: positive attitudes, pragmatism and scepticism. A smaller cluster suggested possible guilt about ability to perform hand hygiene. Cluster analysis identified previously unsuspected constellations of beliefs about hand hygiene that offer a plausible explanation for behaviour. Healthcare workers might respond to education and audit differently according to these beliefs. Those holding predominantly positive opinions might comply with hand hygiene policy and perform well as infection prevention link nurses and champions. Those holding pragmatic attitudes are likely to respond favourably to the need for professional behaviour and need to protect themselves from infection. Greater persuasion may be needed to encourage those who are sceptical about the importance of hand hygiene to comply with guidelines. Interventions to increase compliance should be sufficiently broad in scope to tackle different beliefs. Alternatively, cluster analysis of hand hygiene beliefs could be used to identify the most effective educational and monitoring strategies for a particular clinical setting. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  4. Comparison between rinse and crush-and-rub sampling for aerobic bacteria recovery from broiler hatching eggs after sanitization

    USDA-ARS?s Scientific Manuscript database

    This study compared surface and deep eggshell aerobic bacteria recovered by rinse and crush-and-rub sampling methods for commercial hatching eggs after treatment with sanitizers. Eggs were arranged into 5 treatments consisting of No-treatment, Water, and three sanitizers. Sanitizers were Hydrogen ...

  5. Hand Hygiene Improvement and Sustainability: Assessing a Breakthrough Collaborative in Western Switzerland.

    PubMed

    Staines, Anthony; Amherdt, Isabelle; Lécureux, Estelle; Petignat, Christiane; Eggimann, Philippe; Schwab, Marcos; Pittet, Didier

    2017-12-01

    OBJECTIVE To assess hand hygiene improvement and sustainability associated with a Breakthrough Collaborative. DESIGN Multicenter analysis of hand hygiene compliance through direct observation by trained observers. SETTING A total of 5 publicly funded hospitals in 14 locations, with a total of 1,152 beds, in the County of Vaud, Switzerland. PARTICIPANTS Clinical staff. INTERVENTIONS In total, 59,272 opportunities for hand hygiene were monitored for the duration of the study, for an average of 5,921 per audit (range, 5,449-6,852). An 18-month Hand Hygiene Breakthrough Collaborative was conducted to implement the WHO multimodal promotional strategy including improved access to alcohol-based hand rub, education, performance measurement and feedback, reminders and communication, leadership engagement, and safety culture. RESULTS Overall hand hygiene compliance improved from 61.9% to 88.3% (P<.001) over 18 months and was sustained at 88.9% (P=.248) 12 months after the intervention. Hand hygiene compliance among physicians increased from 62% to 85% (P<.001) and finally 86% at follow-up (P=.492); for nursing staff, compliance improved from 64% to 90% (P<.001) and finally 90% at follow-up (P=.464); for physiotherapists compliance improved from 50% to 90% (P<.001) and finally 91% at follow-up (P=.619); for X-ray technicians compliance improved from 45% to 80% (P<.001) and finally 81% at follow-up (P=.686). Hand hygiene compliance also significantly increased with sustained improvement across all hand hygiene indications and all hospitals. CONCLUSIONS A rigorously conducted multicenter project combining the Breakthrough Collaborative method for its structure and the WHO multimodal strategy for content and measurement was associated with significant and substantial improvement in compliance across all professions, all hand hygiene indications, and all participating hospitals. Infect Control Hosp Epidemiol 2017;38:1420-1427.

  6. Testing of the World Health Organization-recommended formulations for surgical hand preparation and proposals for increased efficacy.

    PubMed

    Suchomel, M; Kundi, M; Allegranzi, B; Pittet, D; Rotter, M L

    2011-10-01

    The 2009 World Health Organization (WHO) Guidelines on hand hygiene in health care recommend alcohol-based hand rubs for both hygienic and pre-surgical hand treatment. Two formulations based on ethanol 80% v/v and 2-propanol 75% v/v are proposed for local preparation in healthcare settings where commercial products are not available or too expensive. Both formulations and our suggested modifications (using mass rather than volume percent concentrations) were evaluated for their conformity with the efficacy requirements of the forthcoming amendment of the European Norm (EN) 12791, i.e. non-inferiority of a product when compared with a reference procedure (1-propanol 60% v/v for 3 min) immediately and 3 h after antisepsis. In this study, the WHO-recommended formulations were tested for 3 min and 5 min. Neither formulation met the efficacy requirements of EN 12791 with 3 min application. Increasing the respective concentrations to 80 w/w (85% v/v) and 75 w/w (80% v/v), together with a prolonged application of 5 min, rendered the immediate effect of both formulations non-inferior to the reference antisepsis procedure. This was not the case with the 3h effect, which remained significantly inferior to the reference. Although the original formulations do not meet the efficacy requirements of EN 12791, the clinical significance of this finding deserves further clinical trials. To comply with the requirement of EN 12791, an amendment to the formulations is possible by increasing the alcohol concentrations through changing volume into mass percent and prolonging the duration of application from 3 min to 5 min. Copyright © 2011 World Health Organization. Published by Elsevier Ltd on behalf of the Healthcare Infection Society. Published by Elsevier Ltd.. All rights reserved.

  7. The use of a measure of acute irritation to predict the outcome of repeated usage of hand soap products.

    PubMed

    Williams, C; Wilkinson, M; McShane, P; Pennington, D; Fernandez, C; Pierce, S

    2011-06-01

    Healthcare-associated infection is an important worldwide problem that could be reduced by better hand hygiene practice. However, an increasing number of healthcare workers are experiencing irritant contact dermatitis of the hands as a result of repeated hand washing. This may lead to a reduced level of compliance with regard to hand hygiene. To assess whether a measure of acute irritation by hand soaps could predict the effects of repeated usage over a 2-week period. In a double-blind, randomized comparison study, the comparative irritation potential of four different hand soaps was assessed over a 24-h treatment period. The effect of repeated hand washing with the hand soap products over a 2-week period in healthy adult volunteers on skin barrier function was then determined by assessment of transepidermal water loss (TEWL), epidermal hydration and a visual assessment using the Hand Eczema Severity Index (HECSI) at days 0, 7 and 14. A total of 121 subjects from the 123 recruited completed phase 1 of the study. All four products were seen to be significantly different from each other in terms of the irritant reaction observed and all products resulted in a significantly higher irritation compared with the no-treatment control. Seventy-nine of the initial 121 subjects were then enrolled into the repeated usage study. A statistically significant worsening of the clinical condition of the skin as measured by HECSI was seen from baseline to day 14 in those subjects repeatedly washing their hands with two of the four soap products (products C and D) with P-values of 0·02 and 0·01, respectively. Subclinical assessment of the skin barrier function by measuring epidermal hydration was significantly increased from baseline to day 7 after repeated hand washing with products A, B and D but overall no significant change was seen in all four products tested by day 14. A statistically significant increase in TEWL at day 14 was seen for product A (P = 0·02) indicating a

  8. Establishment of an efficient virus-induced gene silencing (VIGS) assay in Arabidopsis by Agrobacterium-mediated rubbing infection.

    PubMed

    Manhães, Ana Marcia E de A; de Oliveira, Marcos V V; Shan, Libo

    2015-01-01

    Several VIGS protocols have been established for high-throughput functional genomic screens as it bypasses the time-consuming and laborious process of generation of transgenic plants. The silencing efficiency in this approach is largely hindered by a technically demanding step in which the first pair of newly emerged true leaves at the 2-week-old stage are infiltrated with a needleless syringe. To further optimize VIGS efficiency and achieve rapid inoculation for a large-scale functional genomic study, here we describe a protocol of an efficient VIGS assay in Arabidopsis using Agrobacterium-mediated rubbing infection. The Agrobacterium inoculation is performed by simply rubbing the leaves with Filter Agent Celite(®) 545. The highly efficient and uniform silencing effect was indicated by the development of a visibly albino phenotype due to silencing of the Cloroplastos alterados 1 (CLA1) gene in the newly emerged leaves. In addition, the albino phenotype could be observed in stems and flowers, indicating its potential application for gene functional studies in the late vegetative development and flowering stages.

  9. Loss of Productivity Due to Neck/Shoulder Symptoms and Hand/Arm Symptoms: Results from the PROMO-Study

    PubMed Central

    IJmker, Stefan; Blatter, Birgitte M.; de Korte, Elsbeth M.

    2007-01-01

    Introduction The objective of the present study is to describe the extent of productivity loss among computer workers with neck/shoulder symptoms and hand/arm symptoms, and to examine associations between pain intensity, various physical and psychosocial factors and productivity loss in computer workers with neck/shoulder and hand/arm symptoms. Methods A cross-sectional design was used. The study population consisted of 654 computer workers with neck/shoulder or hand/arm symptoms from five different companies. Descriptive statistics were used to describe the occurrence of self-reported productivity loss. Logistic regression analyses were used to examine the associations. Results In 26% of all the cases reporting symptoms, productivity loss was involved, the most often in cases reporting both symptoms (36%). Productivity loss involved sickness absence in 11% of the arm/hand cases, 32% of the neck/shoulder cases and 43% of the cases reporting both symptoms. The multivariate analyses showed statistically significant odds ratios for pain intensity (OR: 1.26; CI: 1.12–1.41), for high effort/no low reward (OR: 2.26; CI: 1.24–4.12), for high effort/low reward (OR: 1.95; CI: 1.09–3.50), and for low job satisfaction (OR: 3.10; CI: 1.44–6.67). Physical activity in leisure time, full-time work and overcommitment were not associated with productivity loss. Conclusion In most computer workers with neck/shoulder symptoms or hand/arm symptoms productivity loss derives from a decreased performance at work and not from sickness absence. Favorable psychosocial work characteristics might prevent productivity loss in symptomatic workers. PMID:17636455

  10. Does the clinical use of ethanol-based hand sanitizer elevate blood alcohol levels? A prospective study.

    PubMed

    Miller, Michael A; Rosin, Alex; Levsky, Marc E; Patel, Manish M; Gregory, Timothy J D; Crystal, Chad S

    2006-11-01

    Ethanol-based hand sanitizers (EBHSs) are used in most health care facilities in the United States. Infection control personnel advocate the use of generous quantities of EBHS before and after contact with patients. Although it is assumed that little systemic absorption of ethanol occurs during EBHS use, many alcohols are absorbed to varying degrees via the transdermal route. Ethanol intoxication by employees in the medical workplace is a potentially serious finding, and it is of forensic and medical-legal importance to elucidate the effects of frequent use of EBHS upon serum blood ethanol levels (BELs). To investigate the effect of frequent use of EBHS upon serum blood ethanol concentrations, we prospectively studied 5 volunteers undergoing frequent application of EBHS. Enrolled subjects applied 5 mL of the product (62% denatured ethyl alcohol manufactured by Kimberley-Clark, Roswell, GA) to both hands and rubbed until dry. This activity was repeated 50 times over 4 hours. Participants had their blood drawn before as well as after completing the study. Each participant was without alcohol exposure during the 12 hours preceding the study. Five volunteers were enrolled. All had an initial blood ethanol level of less than 5 mg/dL. All 5 participants completed the 4-hour study. There were no noted adverse reactions during the study. Blood ethanol level upon completion of the 50 applications of EBHS was less than 5 mg/dL in all 5 study participants. The results of this study demonstrate that use of ethanol-based hand sanitizers, when frequently used in accordance with labeling, do not raise serum blood ethanol levels.

  11. Stability of hand force production. I. Hand level control variables and multifinger synergies.

    PubMed

    Reschechtko, Sasha; Latash, Mark L

    2017-12-01

    We combined the theory of neural control of movement with referent coordinates and the uncontrolled manifold hypothesis to explore synergies stabilizing the hand action in accurate four-finger pressing tasks. In particular, we tested a hypothesis on two classes of synergies, those among the four fingers and those within a pair of control variables, stabilizing hand action under visual feedback and disappearing without visual feedback. Subjects performed four-finger total force and moment production tasks under visual feedback; the feedback was later partially or completely removed. The "inverse piano" device was used to lift and lower the fingers smoothly at the beginning and at the end of each trial. These data were used to compute pairs of hypothetical control variables. Intertrial analysis of variance within the finger force space was used to quantify multifinger synergies stabilizing both force and moment. A data permutation method was used to quantify synergies among control variables. Under visual feedback, synergies in the spaces of finger forces and hypothetical control variables were found to stabilize total force. Without visual feedback, the subjects showed a force drift to lower magnitudes and a moment drift toward pronation. This was accompanied by disappearance of the four-finger synergies and strong attenuation of the control variable synergies. The indexes of the two types of synergies correlated with each other. The findings are interpreted within the scheme with multiple levels of abundant variables. NEW & NOTEWORTHY We extended the idea of hierarchical control with referent spatial coordinates for the effectors and explored two types of synergies stabilizing multifinger force production tasks. We observed synergies among finger forces and synergies between hypothetical control variables that stabilized performance under visual feedback but failed to stabilize it after visual feedback had been removed. Indexes of two types of synergies correlated

  12. Hand disinfection in a neonatal intensive care unit: continuous electronic monitoring over a one-year period.

    PubMed

    Helder, Onno K; van Goudoever, Johannes B; Hop, Wim C J; Brug, Johannes; Kornelisse, René F

    2012-10-08

    Good hand hygiene compliance is essential to prevent nosocomial infections in healthcare settings. Direct observation of hand hygiene compliance is the gold standard but is time consuming. An electronic dispenser with built-in wireless recording equipment allows continuous monitoring of its usage. The purpose of this study was to monitor the use of alcohol-based hand rub dispensers with a built-in electronic counter in a neonatal intensive care unit (NICU) setting and to determine compliance with hand hygiene protocols by direct observation. A one-year observational study was conducted at a 27 bed level III NICU at a university hospital. All healthcare workers employed at the NICU participated in the study. The use of bedside dispensers was continuously monitored and compliance with hand hygiene was determined by random direct observations. A total of 258,436 hand disinfection events were recorded; i.e. a median (interquartile range) of 697 (559-840) per day. The median (interquartile range) number of hand disinfection events performed per healthcare worker during the day, evening, and night shifts was 13.5 (10.8 - 16.7), 19.8 (16.3 - 24.1), and 16.6 (14.2 - 19.3), respectively. In 65.8% of the 1,168 observations of patient contacts requiring hand hygiene, healthcare workers fully complied with the protocol. We conclude that the electronic devices provide useful information on frequency, time, and location of its use, and also reveal trends in hand disinfection events over time. Direct observations offer essential data on compliance with the hand hygiene protocol. In future research, data generated by the electronic devices can be supplementary used to evaluate the effectiveness of hand hygiene promotion campaigns.

  13. A test procedure for evaluating surgical hand disinfection.

    PubMed

    Babb, J R; Davies, J G; Ayliffe, G A

    1991-06-01

    A technique for assessing the immediate and prolonged efficacy of surgical scrubs and alcoholic hand rubs is described. A mean baseline count is obtained from all volunteers and logarithmic reductions in resident skin flora immediately after one or more applications, and after wearing gloves for 3 h, are measured. Loose-fitting surgical gloves are used for sampling resident flora. Preparations were applied using a standard technique for 2 min, apart from one test with 70% isopropanol (IPA) in which the application time was 30 s. Two studies are described, one of which compared four chlorhexidine scrubs, and the second 70% IPA, 7.5% povidone-iodine scrub, 2% triclosan cleanser and unmedicated bar soap. In spite of their constituent similarity, the four chlorhexidine scrubs varied considerably in efficacy and user acceptability. A 2 min application of 70% IPA was the most effective treatment, and gave log10 reductions of 1.65 for immediate and 1.58 for prolonged effect. This was marginally more effective than a 30 s application, but the difference was not significant. 'Hibiscrub' was the most effective aqueous formulation and gave reductions of 1.01 for immediate effect and 1.16 for prolonged effect. The test described could be used by reference centres and manufacturers to assess the efficacy of new and existing surgical hand disinfection formulations.

  14. Neutralization efficiency of alcohol based products used for rapid hand disinfection

    PubMed

    Chojecka, Agnieszka; Tarka, Patryk; Kierzkowska, Anna; Nitsch-Osuch, Aneta; Kanecki, Krzysztof

    Alcohols are the most commonly used active substances in preparations for quick hand disinfection. They should be bactericidal in very short contact time. PN-EN 13727 + A2: 2015-12 standard, for testing hygienic and surgical handrub disinfection preparations, provides mandatory test conditions of disinfectants in contact times with the range of 30 s to 60 s (hygienic handrub disinfection) and 60 s to 5 min (surgical handrub disinfection). A short contact times for hand hygiene products require a short time of neutralization process. For contact times less than or equal to 10 minutes, the estimated neutralization time is 10 s ± 1 s. Neutralization is a process that abolishes the action of disinfectants. Correct application of this process allows for proper use of disinfectants in practice and its biocidal effect. Objectives. Verification of the effectiveness of 10-second neutralization time of alcohol based preparations for hygienic handrub disinfection Neutralization of two products with different ethanol content (89% and 70%) for hygienic handrub disinfection according to PN-EN 13727 + A2: 2015-12 was investigated. The effectiveness of the neutralizer was assessed by determining toxicity of neutralizer, activity of residual effects of the tested products and their derivatives produced during neutralization (10 s) for test organisms (Staphylococcus aureus ATCC 6538; Pseudomonas aeruginosa ATCC 15442; Enterococcus hirae ATCC 10541; Escherichia coli K12 NCTC 10538) The 10-second neutralization time was sufficient to eliminate the residual activity of products for hygienic handrub disinfection with differentiated ethanol concentration. The neutralizer used did not show toxicity to bacteria and did not produce toxic products with tested preparations after neutralization Conclusions. The use of 10-second neutralization time allows in a precise way designate the contact times for hygienic handrub disinfection products

  15. Nanomachining by rubbing at ultrasonic frequency under controlled shear force.

    PubMed

    Muraoka, Mikio

    2011-03-01

    This study proposes a new method of proximal-probe machining that uses a rubbing process by introducing concentrated-mass (CM) cantilevers. At the second resonance of the CM cantilever vibration, the tip site of the cantilever becomes a node of the standing deflection wave because of the sufficient inertia of the attached concentrated mass. The tip makes a cyclic motion that is tangential to the sample surface, not vertical to it, as in a tapping motion. This lateral tip motion that is selectively excited by CM cantilevers was effective for the material modification of a sample due to the friction between the tip and the sample. Imaging and nanomachining under controlled shear force were demonstrated by means of the modified cantilever and a normal atomic force microscope. We were able to write a micron-sized letter "Z" having a line width of 30-100 nm on a resin surface.

  16. Impact of a standardized hand hygiene program on the incidence of nosocomial infection in very low birth weight infants.

    PubMed

    Capretti, Maria Grazia; Sandri, Fabrizio; Tridapalli, Elisabetta; Galletti, Silvia; Petracci, Elisabetta; Faldella, Giacomo

    2008-08-01

    This study examined the effects of a standardized hand hygiene program on the rate of nosocomial infection (NI) in very low birth weight (VLBW) infants (birth weight < 1500 g) admitted to our neonatal intensive care unit (NICU). We compared the rate of NI in VLBW infants in 2 separate periods. In the first period, staff were encouraged to perform handwashing using a plain fluid detergent (0.5% triclosan). In the second period, a standardized hand hygiene program was implemented using antimicrobial soap (4% chlorhexidine gluconate) and alcohol-based hand rubs. NI after 72 hours of life was detected in 16 of the 85 VLBW infants in the first period and in 5 of the 80 VLBW infants in the second period. The rate of central venous catheter colonization was significantly lower in the second period (5.8%) than in the first period (16.6%). In our NICU, the incidence of NI in VLBW infants was significantly reduced after the introduction of a standardized handwashing protocol. In our experience, a proper hand hygiene program can save approximately 10 NI episodes/year, at a cost of $10,000 per episode. Therefore, improving hand hygiene practice is a cost-effective program in the NICU.

  17. Exploring the olfactory environment of premature newborns: a French survey of health care and cleaning products used in neonatal units.

    PubMed

    Kuhn, Pierre; Astruc, Dominique; Messer, Jean; Marlier, Luc

    2011-03-01

    To assess the main determinants of the newborn's nosocomial olfactory environment. An electronic questionnaire was sent to 99 neonatal units in France. Senior nurses and/or physicians described the nature and use of skin care products (e.g. umbilical cord and skin disinfectants, adhesive removers), lubrications used for tubes positioning, disinfectants used to clean materials, hand hygiene products (e.g. alcohol-based hand rubs, soaps) and newborns' bath. Nine groups of products and 76 distinct commercial preparations were identified. Depending on their level of respiratory support, preterm newborns were estimated to be exposed to nosocomial odours (NO) an average of 1320-1800 times during their first month of life. During their whole hospital stay, newborns of 28 and 32 weeks of gestational age could be exposed to NOs products an average of 3448 and 2024 times, respectively. The use of these products varied among medical centres. Newborns were most frequently exposed to the odour of aqueous alcoholic solutions. Vulnerable preterm infants are daily exposed to multiple NOs most of them be considered as irritant for the nose. Minimizing infants' exposure to them would be beneficial. Future studies should describe the exact olfactory properties of the products considered essential for infant care and should assess their effects on the infant's well-being and development. © 2010 The Author(s)/Acta Paediatrica © 2010 Foundation Acta Paediatrica.

  18. A comparison of hand washing techniques to remove Escherichia coli and caliciviruses under natural or artificial fingernails.

    PubMed

    Lin, Chia-Min; Wu, Fone-Mao; Kim, Hoi-Kyung; Doyle, Michael P; Michael, Barry S; Williams, L Keoki

    2003-12-01

    Compared with other parts of the hand, the area beneath fingernails harbors the most microorganisms and is most difficult to clean. Artificial fingernails, which are usually long and polished, reportedly harbor higher microbial populations than natural nails. Hence, the efficacy of different hand washing methods for removing microbes from natural and artificial fingernails was evaluated. Strains of nonpathogenic Escherichia coli JM109 and feline calicivirus (FCV) strain F9 were used as bacterial and viral indicators, respectively. Volunteers with artificial or natural nails were artificially contaminated with ground beef containing E. coli JM109 or artificial feces containing FCV. Volunteers washed their hands with tap water, regular liquid soap, antibacterial liquid soap, alcohol-based hand sanitizer gel, regular liquid soap followed by alcohol gel, or regular liquid soap plus a nailbrush. The greatest reduction of inoculated microbial populations was obtained by washing with liquid soap plus a nailbrush, and the least reduction was obtained by rubbing hands with alcohol gel. Lower but not significantly different (P > 0.05) reductions of E. coli and FCV counts were obtained from beneath artificial than from natural fingernails. However, significantly (P < or = 0.05) higher E. coli and FCV counts were recovered from hands with artificial nails than from natural nails before and after hand washing. In addition, microbial cell numbers were correlated with fingernail length, with greater numbers beneath fingernails with longer nails. These results indicate that best practices for fingernail sanitation of food handlers are to maintain short fingernails and scrub fingernails with soap and a nailbrush when washing hands.

  19. [Moving cupping at Hechelu combined with rubbing method for depression of diabetes mellitus].

    PubMed

    He, Lingna; Du, Ping; Shen, Zhifu; Wang, Xuan

    2016-03-01

    To compare the efficacy between moving cupping at Hechelu combined with rubbing method and western medication for depression of diabetes mellitus (DM). Two hundred and sixteen patients were randomly divided into an observation group and a control group, 108 cases in each group. Patients in the observation group were treated with moving cupping at Hechelu combined with rubbing method, once every: other day; six treatments were considered as one course, and totally two courses were given with an interval of: 4 days between courses. Patients in the control group were treated with oral administration of fluoxetine hydrochloride capsules, once a day for consecutive 4 weeks. The Hamilton depression scale (HAMD), self-rating depression scale (SDS) and TCM symptom score were measured before treatment, after the treatment and in follow-up visit one and a half months after treatment. The fasting blood glucose was tested before and after treatment. The glycosylated hemoglobin (HbA1c) was tested in the follow-up visit. The total effective rate was 90.9% (90/99) in the observation group, which was superior to 73.7% (70/95) in the control group (P < 0.05). After the treatment, HAMD, SDS and TCM symptom scores were all reduced apparently in the observation group and the control group (all P < 0.05). After the treatment and the follow-up visit, the TCM symptom score in the observation group was lower than that in the control group (P < 0.05). The levels of HbA1c and GLU were stable in the observation group, and were decreased compared with those before treatment; but the difference between the, two groups was not significant (P > 0.05). The Hechelu theory-based TCM treatment has better: efficacy for depression of diabetes mellitus than fluoxetine hydrochloride capsule, which has less adverse effects.

  20. Estimating dermal transfer from PCB-contaminated porous surfaces.

    PubMed

    Slayton, T M; Valberg, P A; Wait, A D

    1998-06-01

    Health risks posed by dermal contact with PCB-contaminated porous surfaces have not been directly demonstrated and are difficult to estimate indirectly. Surface contamination by organic compounds is commonly assessed by collecting wipe samples with hexane as the solvent. However, for porous surfaces, hexane wipe characterization is of limited direct use when estimating potential human exposure. Particularly for porous surfaces, the relationship between the amount of organic material collected by hexane and the amount actually picked up by, for example, a person's hand touch is unknown. To better mimic PCB pickup by casual hand contact with contaminated concrete surfaces, we used alternate solvents and wipe application methods that more closely mimic casual dermal contact. Our sampling results were compared to PCB pickup using hexane-wetted wipes and the standard rubbing protocol. Dry and oil-wetted samples, applied without rubbing, picked up less than 1% of the PCBs picked up by the standard hexane procedure; with rubbing, they picked up about 2%. Without rubbing, saline-wetted wipes picked up 2.5%; with rubbing, they picked up about 12%. While the nature of dermal contact with a contaminated surface cannot be perfectly reproduced with a wipe sample, our results with alternate wiping solvents and rubbing methods more closely mimic hand contact than the standard hexane wipe protocol. The relative pickup estimates presented in this paper can be used in conjunction with site-specific PCB hexane wipe results to estimate dermal pickup rates at sites with PCB-contaminated concrete.

  1. Association between use of hand hygiene products and rates of health care-associated infections in a large university hospital in Norway.

    PubMed

    Herud, Trine; Nilsen, Roy M; Svendheim, Kjersti; Harthug, Stig

    2009-05-01

    An association between use of hand hygiene products and health care-associated infection rates was investigated in a large Norwegian university hospital. We conducted an ecologic study by combining data from purchasing and admission systems with data from 32 point prevalence surveys (27,248 patients) in 1998-2005. Data on purchase of hand disinfectants and soap, and patient-days, were collected for 20 bed wards similar to those of the prevalence surveys. The prevalence of infections was 7.1%. We found no significant decline in overall infections (P = .19), but use of hand hygiene products significantly increased from 28.5 L per 1000 patients-days in 1998 to 43.3 L per 1000 patient-days in 2005 (P < .001). After examining a linear dose-response relation between use and infection rates, we observed a borderline significant decline in infections from 8% to 6% with increased use of hand hygiene products (P = .05). This association appeared stronger for wards that were registered with infections >9% at study start in 1998 (P < .001). These data suggests that infection rates may be reflected by amount of hand hygiene products used. Quantification of such products over time may serve as an indicator for hand hygiene performance in hospitals.

  2. Brush seal bristle flexure and hard-rub characteristics

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1993-01-01

    The bristles of a 38.1-mm (1.5-in.) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in.) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in.) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in.) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in.) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping', and hot spots and streaks were found. With a smooth-plug rotor, post-test leakage increased 30 percent over pretest leakage.

  3. Brush seal low surface speed hard-rub characteristics

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1993-01-01

    The bristles of a 38.1-mm (1.5-in.) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in.) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in.) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in.) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in.) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping,' and hot spots and streaks were found. With a smooth-plug rotor, post-test leakage increased 30 percent over pretest leakage.

  4. Brush seal bristle flexure and hard-rub characteristics

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1992-01-01

    The bristles of a 38.1-mm (1.5-in) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping,' and hot spots and streaks were found. With a smooth-plug rotor post-test leakage increased 30 percent over pretest leakage.

  5. Brush seal bristle flexure and hard-rub characteristics

    NASA Astrophysics Data System (ADS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1992-08-01

    The bristles of a 38.1-mm (1.5-in) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping,' and hot spots and streaks were found. With a smooth-plug rotor post-test leakage increased 30 percent over pretest leakage.

  6. Brush seal bristle flexure and hard-rub characteristics

    NASA Astrophysics Data System (ADS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1993-10-01

    The bristles of a 38.1-mm (1.5-in.) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in.) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in.) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in.) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in.) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping', and hot spots and streaks were found. With a smooth-plug rotor, post-test leakage increased 30 percent over pretest leakage.

  7. Brush seal low surface speed hard-rub characteristics

    NASA Astrophysics Data System (ADS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1993-06-01

    The bristles of a 38.1-mm (1.5-in.) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in.) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in.) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in.) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in.) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping,' and hot spots and streaks were found. With a smooth-plug rotor, post-test leakage increased 30 percent over pretest leakage.

  8. Interventions to improve hand hygiene compliance in patient care.

    PubMed

    Gould, Dinah J; Moralejo, Donna; Drey, Nicholas; Chudleigh, Jane H; Taljaard, Monica

    2017-09-01

    Health care-associated infection is a major cause of morbidity and mortality. Hand hygiene is regarded as an effective preventive measure. This is an update of a previously published review. To assess the short- and long-term success of strategies to improve compliance to recommendations for hand hygiene, and to determine whether an increase in hand hygiene compliance can reduce rates of health care-associated infection. We conducted electronic searches of the Cochrane Register of Controlled Trials, PubMed, Embase, and CINAHL. We conducted the searches from November 2009 to October 2016. We included randomised trials, non-randomised trials, controlled before-after studies, and interrupted time series analyses (ITS) that evaluated any intervention to improve compliance with hand hygiene using soap and water or alcohol-based hand rub (ABHR), or both. Two review authors independently screened citations for inclusion, extracted data, and assessed risks of bias for each included study. Meta-analysis was not possible, as there was substantial heterogeneity across studies. We assessed the certainty of evidence using the GRADE approach and present the results narratively in a 'Summary of findings' table. This review includes 26 studies: 14 randomised trials, two non-randomised trials and 10 ITS studies. Most studies were conducted in hospitals or long-term care facilities in different countries, and collected data from a variety of healthcare workers. Fourteen studies assessed the success of different combinations of strategies recommended by the World Health Organization (WHO) to improve hand hygiene compliance. Strategies consisted of the following: increasing the availability of ABHR, different types of education for staff, reminders (written and verbal), different types of performance feedback, administrative support, and staff involvement. Six studies assessed different types of performance feedback, two studies evaluated education, three studies evaluated cues such

  9. The mechanical forces in katydid sound production

    NASA Astrophysics Data System (ADS)

    Xiao, Huaping; Chiu, Cheng-Wei; Zhou, Yan; He, Xingliang; Epstein, Ben; Liang, Hong

    2013-10-01

    Katydids and crickets generate their characteristic calling sound by rubbing their wings together. The mechanisms of the rubbing force, however, have not been extensively studied. The change of mechanical force with external parameters (speed and applied load) in the stridulation process has not been reported. Our current study aims to investigate the mechanical forces of katydid stridulation. Four pairs of files and plectrums from a katydid, which are responsible for the katydid's sound production, were examined with a specially designed experimental configuration. Due to the asymmetric nature of the wing motion in their opening and closing, the contact between the plectrum and file resembles that of a ratchet. Multiple frequencies were generated during experimental wing rubbing so that a calling-like sound was produced. Results showed that the morphology of the plectrum/file contact has significant effects on mechanical forces induced on the wings and resulting sound production. The roles of the mechanical forces include sound generation, tone modification, and energy consumption. The findings in this work reveal the variation trend of mechanical force with sliding speed and applied load. The frequency and amplitude of the sound wave produced in tribo-test are close to those in natural condition. By mimicking the microstructure of the plectrum and file teeth, acoustic instruments with high mechanical energy conversion rate can be developed. Our results provide new approaches in the design and improvement of micro-machines for acoustic applications, as well as in hybrid robotic systems.

  10. Guidelines for Mass Casualty Decontamination During a HAZMAT/Weapon of Mass Destruction Incident. Volumes 1 and 2 (Update)

    DTIC Science & Technology

    2013-08-01

    neutralization: 1. Physical removal involves mechanical action with techniques such as gentle fric- tion (such as rubbing with hands, soft non...sulfur mustard), using gen- tle friction, such as rubbing with hands, a soft cloth, or sponges is recommended to aid in re- moval of the contaminants...account for both initial mass decontamination and secondary de- contamination. Some examples include the use of colored rubber bands and specially de

  11. OsB 2 and RuB 2, ultra-incompressible, hard materials: First-principles electronic structure calculations

    NASA Astrophysics Data System (ADS)

    Chiodo, S.; Gotsis, H. J.; Russo, N.; Sicilia, E.

    2006-07-01

    Recently it has been reported that osmium diboride has an unusually large bulk modulus combined with high hardness, and consequently is a most interesting candidate as an ultra-incompressible and hard material. The electronic and structural properties of the transition metal diborides OsB 2 and RuB 2 have been calculated within the local density approximation (LDA). It is shown that the high hardness is the result of covalent bonding between transition metal d states and boron p states in the orthorhombic structure.

  12. Hands of beauty, hands of horror: fear and Egyptian art at the Fin de Siècle.

    PubMed

    Briefel, Aviva

    2008-01-01

    This essay examines the gothicization of Egyptian manual productions in late-Victorian mummy narratives. These narratives often isolate the mummy's hand as a signifier of craftsmanship, a troubling object for a culture that was mourning the figurative loss of its artisans' hands to mechanized production. Focusing on Bram Stoker's 1903 novel, The Jewel of Seven Stars, I contend that the horror of the mummy's hand emanates from its ambiguous position as an artifact that is itself a means of production. It displaces Friedrich Engels's conception of the Western hand as a self-creating appendage into the atavistic domain of a long-lost Egyptian tradition, and in doing so, it forces the English observer to recognize the irrecoverable nature of aesthetic craftsmanship. Brought into violent contact with the creative potential of the mummy's hand, the characters in Stoker's novel try to disassociate the mummy from manual production but only succeed in confirming their own status as products of a mechanized age.

  13. Exploring the potential of antimicrobial hand hygiene products in reducing the infectious burden in low-income countries: An integrative review.

    PubMed

    de Witt Huberts, Jessie; Greenland, Katie; Schmidt, Wolf-Peter; Curtis, Val

    2016-07-01

    The purpose of this review was to understand whether adding antimicrobial agents to hand hygiene products could increase the health benefits of handwashing with plain soap (HWWS) in low-income settings. A review of experimental studies comparing the effects of HWWS with antimicrobial soap and waterless hand sanitizer on health and hand contamination in naturalistic conditions was conducted. In addition, an analysis was completed of the evidence from laboratory studies examining the factors that may affect the impact of antimicrobial soap, taking into account the conditions in low-income settings. The review found no evidence for a superior effect of antimicrobial products compared with HWWS on disease incidence and limited evidence for an effect on hand contamination under naturalistic conditions. An analysis of the effectiveness of antimicrobial soap in laboratory settings suggested that it was only more effective than HWWS when handwashing frequency, duration, and product concentrations were above levels that could be expected in low-income settings. The limited available evidence suggests that under naturalistic conditions, antimicrobial products are no more effective than HWWS in removing pathogens from hands. Without significant improvement in efficacy, antimicrobial products are unlikely to produce greater health gains than HWWS in low-income settings. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  14. 21 CFR 347.50 - Labeling of skin protectant drug products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... states “dries the oozing and weeping of poison: [bullet] ivy [bullet] oak [bullet] sumac”. (4) For...) “When using this product [bullet] do not get into eyes”. (3) “Stop use and ask a doctor if [bullet... doctor [bullet] pat dry (do not rub) to keep a thin layer on the skin”. (B) For products used as a...

  15. Effectiveness of Liquid Soap and Hand Sanitizer against Norwalk Virus on Contaminated Hands▿

    PubMed Central

    Liu, Pengbo; Yuen, Yvonne; Hsiao, Hui-Mien; Jaykus, Lee-Ann; Moe, Christine

    2010-01-01

    Disinfection is an essential measure for interrupting human norovirus (HuNoV) transmission, but it is difficult to evaluate the efficacy of disinfectants due to the absence of a practicable cell culture system for these viruses. The purpose of this study was to screen sodium hypochlorite and ethanol for efficacy against Norwalk virus (NV) and expand the studies to evaluate the efficacy of antibacterial liquid soap and alcohol-based hand sanitizer for the inactivation of NV on human finger pads. Samples were tested by real-time reverse transcription-quantitative PCR (RT-qPCR) both with and without a prior RNase treatment. In suspension assay, sodium hypochlorite concentrations of ≥160 ppm effectively eliminated RT-qPCR detection signal, while ethanol, regardless of concentration, was relatively ineffective, giving at most a 0.5 log10 reduction in genomic copies of NV cDNA. Using the American Society for Testing and Materials (ASTM) standard finger pad method and a modification thereof (with rubbing), we observed the greatest reduction in genomic copies of NV cDNA with the antibacterial liquid soap treatment (0.67 to 1.20 log10 reduction) and water rinse only (0.58 to 1.58 log10 reduction). The alcohol-based hand sanitizer was relatively ineffective, reducing the genomic copies of NV cDNA by only 0.14 to 0.34 log10 compared to baseline. Although the concentrations of genomic copies of NV cDNA were consistently lower on finger pad eluates pretreated with RNase compared to those without prior RNase treatment, these differences were not statistically significant. Despite the promise of alcohol-based sanitizers for the control of pathogen transmission, they may be relatively ineffective against the HuNoV, reinforcing the need to develop and evaluate new products against this important group of viruses. PMID:19933337

  16. Leptogenesis from Left-Handed Neutrino Production during Axion Inflation.

    PubMed

    Adshead, Peter; Sfakianakis, Evangelos I

    2016-03-04

    We propose that the observed matter-antimatter asymmetry can be naturally produced as a by-product of axion-driven slow-roll inflation by coupling the axion to standard model neutrinos. We assume that grand unified theory scale right-handed neutrinos are responsible for the masses of the standard model neutrinos and that the Higgs field is light during inflation and develops a Hubble-scale root-mean-square value. In this setup, the rolling axion generates a helicity asymmetry in standard model neutrinos. Following inflation, this helicity asymmetry becomes equal to a net lepton number as the Higgs condensate decays and is partially reprocessed by the SU(2)_{L} sphaleron into a net baryon number.

  17. Quantification of the Hawthorne effect in hand hygiene compliance monitoring using an electronic monitoring system: a retrospective cohort study

    PubMed Central

    Srigley, Jocelyn A; Furness, Colin D; Baker, G Ross; Gardam, Michael

    2014-01-01

    Background The Hawthorne effect, or behaviour change due to awareness of being observed, is assumed to inflate hand hygiene compliance rates as measured by direct observation but there are limited data to support this. Objective To determine whether the presence of hand hygiene auditors was associated with an increase in hand hygiene events as measured by a real-time location system (RTLS). Methods The RTLS recorded all uses of alcohol-based hand rub and soap for 8 months in two units in an academic acute care hospital. The RTLS also tracked the movement of hospital hand hygiene auditors. Rates of hand hygiene events per dispenser per hour as measured by the RTLS were compared for dispensers within sight of auditors and those not exposed to auditors. Results The hand hygiene event rate in dispensers visible to auditors (3.75/dispenser/h) was significantly higher than in dispensers not visible to the auditors at the same time (1.48; p=0.001) and in the same dispensers during the week prior (1.07; p<0.001). The rate increased significantly when auditors were present compared with 1–5 min prior to the auditors’ arrival (1.50; p=0.009). There were no significant changes inside patient rooms. Conclusions Hand hygiene event rates were approximately threefold higher in hallways within eyesight of an auditor compared with when no auditor was visible and the increase occurred after the auditors’ arrival. This is consistent with the existence of a Hawthorne effect localised to areas where the auditor is visible and calls into question the accuracy of publicly reported hospital hand hygiene compliance rates. PMID:25002555

  18. Microbial Characteristics of Nosocomial Infections and Their Association with the Utilization of Hand Hygiene Products: A Hospital-Wide Analysis of 78,344 Cases.

    PubMed

    Liu, Song; Wang, Meng; Wang, Gefei; Wu, Xiuwen; Guan, Wenxian; Ren, Jianan

    Nosocomial infections are the main adverse events during health care delivery. Hand hygiene is the fundamental strategy for the prevention of nosocomial infections. Microbial characteristics of nosocomial infections in the Asia-Pacific region have not been investigated fully. Correlation between the use of hand hygiene products and the incidence of nosocomial infections is still unknown. This study investigates the microbial characteristics of nosocomial infections in the Asia-Pacific region and analyzes the association between the utilization of hand hygiene products and the incidence of nosocomial infections. A total of 78,344 patients were recruited from a major tertiary hospital in China. Microbial characteristics of major types of nosocomial infections were described. The association between the utilization of hand hygiene products and the incidence of nosocomial infections was analyzed using correlation and regression models. The overall incidence of nosocomial infections was 3.04%, in which the incidence of surgical site infection was 1%. Multi-drug resistance was found in 22.8% of all pathogens, in which multi-drug-resistant Acinetobacter baumannii and methicillin-resistant Staphylococcus aureus were 56.6% and 54.9%, respectively. The utilization of hand hygiene products (including hand sanitizer, soap and paper towel) was associated negatively with the incidence of surgical site infection in surgical departments and the incidence of nosocomial infections in non-intensive care unit (ICU) departments (especially in surgical departments). Regression analysis further identified that higher utilization of hand hygiene products correlated with decreased incidence of major types of nosocomial infections. Multi-drug-resistant organisms are emerging in Asia-Pacific health care facilities. Utilization of hand hygiene products is associated with the incidence of nosocomial infections.

  19. Guideline Implementation: Hand Hygiene.

    PubMed

    Goldberg, Judith L

    2017-02-01

    Performing proper hand hygiene and surgical hand antisepsis is essential to reducing the rates of health care-associated infections, including surgical site infections. The updated AORN "Guideline for hand hygiene" provides guidance on hand hygiene and surgical hand antisepsis, the wearing of fingernail polish and artificial nails, proper skin care to prevent dermatitis, the wearing of jewelry, hand hygiene product selection, and quality assurance and performance improvement considerations. This article focuses on key points of the guideline to help perioperative personnel make informed decisions about hand hygiene and surgical hand antisepsis. The key points address the necessity of keeping fingernails and skin healthy, not wearing jewelry on the hands or wrists in the perioperative area, properly performing hand hygiene and surgical hand antisepsis, and involving patients and visitors in hand hygiene initiatives. Perioperative RNs should review the complete guideline for additional information and for guidance when writing and updating policies and procedures. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  20. Rubber Flooring Impact on Production and Herdlife of Dairy Cows

    USDA-ARS?s Scientific Manuscript database

    Use of rubber flooring in dairies has become popular because of perceived cow comfort. The overall objective of this longitudinal study was to evaluate production, reproduction, and retention of first and second lactations of cows assigned to either rubber (RUB) or concrete (CON) flooring at the fe...

  1. Hand digit control in children: motor overflow in multi-finger pressing force vector space during maximum voluntary force production.

    PubMed

    Shim, Jae Kun; Karol, Sohit; Hsu, Jeffrey; de Oliveira, Marcio Alves

    2008-04-01

    The aim of this study was to investigate the contralateral motor overflow in children during single-finger and multi-finger maximum force production tasks. Forty-five right handed children, 5-11 years of age produced maximum isometric pressing force in flexion or extension with single fingers or all four fingers of their right hand. The forces produced by individual fingers of the right and left hands were recorded and analyzed in four-dimensional finger force vector space. The results showed that increases in task (right) hand finger forces were linearly associated with non-task (left) hand finger forces. The ratio of the non-task hand finger force magnitude to the corresponding task hand finger force magnitude, termed motor overflow magnitude (MOM), was greater in extension than flexion. The index finger flexion task showed the smallest MOM values. The similarity between the directions of task hand and non-task hand finger force vectors in four-dimensional finger force vector space, termed motor overflow direction (MOD), was the greatest for index and smallest for little finger tasks. MOM of a four-finger task was greater than the sum of MOMs of single-finger tasks, and this phenomenon was termed motor overflow surplus. Contrary to previous studies, no single-finger or four-finger tasks showed significant changes of MOM or MOD with the age of children. We conclude that the contralateral motor overflow in children during finger maximum force production tasks is dependent upon the task fingers and the magnitude and direction of task finger forces.

  2. Cytotoxic and anti-angiogenic paclitaxel solubilized and permeation-enhanced by natural product nanoparticles

    PubMed Central

    Liu, Zhijun; Zhang, Fang; Koh, Gar Yee; Dong, Xin; Hollingsworth, Javoris; Zhang, Jian; Russo, Paul S.; Yang, Peiying; Stout, Rhett W.

    2014-01-01

    Paclitaxel (PTX) is one of the most potent intravenous chemotherapeutic agents to date, yet an oral formulation has been problematic due to its low solubility and permeability. Using the recently discovered solubilizing properties of rubusoside (RUB), we investigated this unique PTX-RUB formulation. Paclitaxel was solubilized by RUB in water to levels of 1.6 to 6.3 mg/mL at 10 to 40% weight/volume. These, nanomicellar, PTX-RUB complexes were dried to a powder which was subsequently reconstituted in physiologic solutions. After 2.5 hrs in gastric fluid 85 to 99% of PTX-RUB remained soluble, while 79 to 96% remained soluble in intestinal fluid. The solubilization of PTX was mechanized by the formation of water-soluble spherical nanomicelles between PTX and RUB with an average diameter of 6.6 nm. Compared with Taxol®, PTX-RUB nanoparticles were nearly four times more permeable in Caco-2 cell monocultures. In a side-by-side comparison with DMSO-solubilized PTX, PTX-RUB maintained the same level of cytotoxicity against three human cancer cell lines with IC50 values ranging from 4 nM to 20 nM. Additionally, tubular formation and migration of HUVECs were inhibited at levels as low as 5 nM. These chemical and biological properties demonstrated by the PTX-RUB nanoparticles may improve oral bioavailability and enable further pharmacokinetic, toxicologic, and efficacy investigations. PMID:25243454

  3. Quantification of the Hawthorne effect in hand hygiene compliance monitoring using an electronic monitoring system: a retrospective cohort study.

    PubMed

    Srigley, Jocelyn A; Furness, Colin D; Baker, G Ross; Gardam, Michael

    2014-12-01

    The Hawthorne effect, or behaviour change due to awareness of being observed, is assumed to inflate hand hygiene compliance rates as measured by direct observation but there are limited data to support this. To determine whether the presence of hand hygiene auditors was associated with an increase in hand hygiene events as measured by a real-time location system (RTLS). The RTLS recorded all uses of alcohol-based hand rub and soap for 8 months in two units in an academic acute care hospital. The RTLS also tracked the movement of hospital hand hygiene auditors. Rates of hand hygiene events per dispenser per hour as measured by the RTLS were compared for dispensers within sight of auditors and those not exposed to auditors. The hand hygiene event rate in dispensers visible to auditors (3.75/dispenser/h) was significantly higher than in dispensers not visible to the auditors at the same time (1.48; p=0.001) and in the same dispensers during the week prior (1.07; p<0.001). The rate increased significantly when auditors were present compared with 1-5 min prior to the auditors' arrival (1.50; p=0.009). There were no significant changes inside patient rooms. Hand hygiene event rates were approximately threefold higher in hallways within eyesight of an auditor compared with when no auditor was visible and the increase occurred after the auditors' arrival. This is consistent with the existence of a Hawthorne effect localised to areas where the auditor is visible and calls into question the accuracy of publicly reported hospital hand hygiene compliance rates. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. Comparison of ethanol hand sanitizer versus moist towelette packets for mealtime patient hand hygiene.

    PubMed

    Rai, Herleen; Knighton, Shanina; Zabarsky, Trina F; Donskey, Curtis J

    2017-09-01

    To facilitate patient hand hygiene, there is a need for easy-to-use products. In a survey of 100 patients, a single-use ethanol hand sanitizer packet took less time to access than a single-use moist towelette packet (3 vs 23 seconds) and was preferred by 74% of patients for mealtime hand hygiene. Performance of patient hand hygiene increased when a reminder was provided at the time of meal tray delivery. Published by Elsevier Inc.

  5. 77 FR 40637 - Honeywell International, Scanning and Mobility Division, Formerly Known as Hand Held Products...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-10

    ..., Scanning and Mobility Division, Formerly Known as Hand Held Products, Inc., Including On-Site Leased Workers From Manpower, Skaneatelles Falls, NY; Amended Certification Regarding Eligibility To Apply for...''), 19 U.S.C. 2273, the Department of Labor issued a Certification of Eligibility to Apply for Worker...

  6. The effect of work system on the hand exposure of workers in 18F-FDG production centres.

    PubMed

    Wrzesień, Małgorzata

    2018-05-07

    The production of the 18 F isotope-the marker of deoxyglucose ( 18 F-FDG)-the radiopharmaceutical most commonly used in the oncological diagnostic technique of positron emission tomography, requires a cyclotron device. At present, there are nine facilities working in Poland that are equipped with cyclotrons used for producing the short-lived isotopes. The aim of the paper is to determine the hand exposure of workers employed in the two 18 F-FDG production centres taking in to account the production procedures and work system in those facilities. Measurements, which included all professional workers exposed to ionizing radiation that were employed in two facilities, were performed by using high-sensitivity thermoluminescent detectors during the routine activities of the personnel. The work system used at the production centre has an impact on the level of the recorded doses. Among the production procedures performed by the staff, the highest ionizing radiation doses have been received by the staff during the 18 F-FDG quality control. The maximum estimated annual Hp(0.07) for chemists from the quality control department can exceed the annual skin limit dose (500 mSv). The source of lowest doses on the hands are the cyclotron operating procedure and the 18 F-FDG production, provided that these procedures can't be combined with other production procedures.

  7. Efficacy of Moringa oleifera leaf powder as a hand-washing product: a crossover controlled study among healthy volunteers.

    PubMed

    Torondel, Belen; Opare, David; Brandberg, Bjorn; Cobb, Emma; Cairncross, Sandy

    2014-02-14

    Moringa oleifera is a plant found in many tropical and subtropical countries. Many different uses and properties have been attributed to this plant, mainly as a nutritional supplement and as a water purifier. Its antibacterial activity against different pathogens has been described in different in vitro settings. However the potential effect of this plant leaf as a hand washing product has never been studied. The aim of this study is to test the efficacy of this product using an in vivo design with healthy volunteers. The hands of fifteen volunteers were artificially contaminated with Escherichia coli. Moringa oleifera leaf powder was tested as a hand washing product and was compared with reference non-medicated liquid soap using a cross over design following an adaptation of the European Committee for Standardization protocol (EN 1499). In a second part of tests, the efficacy of the established amount of Moringa oleifera leaf powder was compared with an inert powder using the same protocol. Application of 2 and 3 g of dried Moringa oleifera leaf powder (mean log10-reduction: 2.44 ± 0.41 and 2.58 ± 0.34, respectively) was significantly less effective than the reference soap (3.00 ± 0.27 and 2.99 ± 0.26, respectively; p < 0.001). Application of the same amounts of Moringa oleifera (2 and 3 g) but using a wet preparation, was also significantly less effective than reference soap (p < 0.003 and p < 0.02, respectively). However there was no significant difference when using 4 g of Moringa oleifera powder in dried or wet preparation (mean log10-reduction: 2.70 ± 0.27 and 2.91 ± 0.11, respectively) compared with reference soap (2.97 ± 0.28). Application of calcium sulphate inert powder was significantly less effective than the 4 g of Moringa oleifera powder (p < 0.01). Four grams of Moringa oleifera powder in dried and wet application had the same effect as non-medicated soap when used for hand washing. Efficacious

  8. Efficacy of Moringa oleifera leaf powder as a hand- washing product: a crossover controlled study among healthy volunteers

    PubMed Central

    2014-01-01

    Background Moringa oleifera is a plant found in many tropical and subtropical countries. Many different uses and properties have been attributed to this plant, mainly as a nutritional supplement and as a water purifier. Its antibacterial activity against different pathogens has been described in different in vitro settings. However the potential effect of this plant leaf as a hand washing product has never been studied. The aim of this study is to test the efficacy of this product using an in vivo design with healthy volunteers. Methods The hands of fifteen volunteers were artificially contaminated with Escherichia coli. Moringa oleifera leaf powder was tested as a hand washing product and was compared with reference non-medicated liquid soap using a cross over design following an adaptation of the European Committee for Standardization protocol (EN 1499). In a second part of tests, the efficacy of the established amount of Moringa oleifera leaf powder was compared with an inert powder using the same protocol. Results Application of 2 and 3 g of dried Moringa oleifera leaf powder (mean log10-reduction: 2.44 ± 0.41 and 2.58 ± 0.34, respectively) was significantly less effective than the reference soap (3.00 ± 0.27 and 2.99 ± 0.26, respectively; p < 0.001). Application of the same amounts of Moringa oleifera (2 and 3 g) but using a wet preparation, was also significantly less effective than reference soap (p < 0.003 and p < 0.02, respectively). However there was no significant difference when using 4 g of Moringa oleifera powder in dried or wet preparation (mean log10-reduction: 2.70 ± 0.27 and 2.91 ± 0.11, respectively) compared with reference soap (2.97 ± 0.28). Application of calcium sulphate inert powder was significantly less effective than the 4 g of Moringa oleifera powder (p < 0.01). Conclusion Four grams of Moringa oleifera powder in dried and wet application had the same effect as non-medicated soap

  9. Reconnaissance investigation of brine in the eastern Rub al Khali, Kingdom of Saudi Arabia

    USGS Publications Warehouse

    Smith, C.L.

    1981-01-01

    Al Uruq al Mu'taridah-Umm as Samim area is located in a large topographic depression in the eastern Rub al Khali desert where playas several thousand square kilometers in area are exposedo A crust of eolian sand cemented with gypsum and halite has formed on many playa surfaces. Anhydrite nodules are common in the sampled area, where the depth to ground water generally exceeds 172 Cmo The chemistry of the three ground-water samples collected near the water well Ramallah-1 (lat 22?10'20'' N., long 54?20'37'' E.) is similar to that of sabkhah-related brines on the coast of the United Arab Emirates. Although there is no indication of economic quantities of evaporite minerals in the sampled area, the extent of the depression and its unique geologic environment recommend it for resource-evaluation studies.

  10. "First-person view" of pathogen transmission and hand hygiene - use of a new head-mounted video capture and coding tool.

    PubMed

    Clack, Lauren; Scotoni, Manuela; Wolfensberger, Aline; Sax, Hugo

    2017-01-01

    Healthcare workers' hands are the foremost means of pathogen transmission in healthcare, but detailed hand trajectories have been insufficiently researched so far. We developed and applied a new method to systematically document hand-to-surface exposures (HSE) to delineate true hand transmission pathways in real-life healthcare settings. A head-mounted camera and commercial coding software were used to capture ten active care episodes by eight nurses and two physicians and code HSE type and duration using a hierarchical coding scheme. We identified HSE sequences of particular relevance to infectious risks for patients based on the WHO 'Five Moments for Hand Hygiene'. The study took place in a trauma intensive care unit in a 900-bed university hospital in Switzerland. Overall, the ten videos totaled 296.5 min and featured eight nurses and two physicians. A total of 4222 HSE were identified (1 HSE every 4.2 s), which concerned bare (79%) and gloved (21%) hands. The HSE inside the patient zone ( n  = 1775; 42%) included mobile objects (33%), immobile surfaces (5%), and patient intact skin (4%), while HSE outside the patient zone ( n  = 1953; 46%) included HCW's own body (10%), mobile objects (28%), and immobile surfaces (8%). A further 494 (12%) events involved patient critical sites. Sequential analysis revealed 291 HSE transitions from outside to inside patient zone, i.e. "colonization events", and 217 from any surface to critical sites, i.e. "infection events". Hand hygiene occurred 97 times, 14 (5% adherence) times at colonization events and three (1% adherence) times at infection events. On average, hand rubbing lasted 13 ± 9 s. The abundance of HSE underscores the central role of hands in the spread of potential pathogens while hand hygiene occurred rarely at potential colonization and infection events. Our approach produced a valid video and coding instrument for in-depth analysis of hand trajectories during active patient care that may help to design

  11. Life cycle-based water assessment of a hand dishwashing product: opportunities and limitations.

    PubMed

    Van Hoof, Gert; Buyle, Bea; Kounina, Anna; Humbert, Sebastien

    2013-10-01

    It is only recently that life cycle-based indicators have been used to evaluate products from a water use impact perspective. The applicability of some of these methods has been primarily demonstrated on agricultural materials or products, because irrigation requirements in food production can be water-intensive. In view of an increasing interest on life cycle-based water indicators from different products, we ran a study on a hand dishwashing product. A number of water assessment methods were applied with the purpose of identifying both product improvement opportunities, as well as understanding the potential for underlying database and methodological improvements. The study covered the entire life cycle of the product and focused on environmental issues related to water use, looking in-depth at inventory, midpoint, and endpoint methods. "Traditional" water emission driven methods, such as freshwater eutrophication, were excluded from the analysis. The use of a single formula with the same global supply chain, manufactured in 1 location was evaluated in 2 countries with different water scarcity conditions. The study shows differences ranging up to 4 orders in magnitude for indicators with similar units associated with different water use types (inventory methods) and different cause-effect chain models (midpoint and endpoint impact categories). No uncertainty information was available on the impact assessment methods, whereas uncertainty from stochastic variability was not available at the time of study. For the majority of the indicators studied, the contribution from the consumer use stage is the most important (>90%), driven by both direct water use (dishwashing process) as well as indirect water use (electricity generation to heat the water). Creating consumer awareness on how the product is used, particularly in water-scarce areas, is the largest improvement opportunity for a hand dishwashing product. However, spatial differentiation in the inventory and

  12. Preoperative Disinfection of Surgeons' Hands: Use of Alcoholic Solutions and Effects of Gloves on Skin Flora

    PubMed Central

    Lowbury, E. J. L.; Lilly, H. A.; Ayliffe, G. A. J.

    1974-01-01

    A single application of about 10 ml of 95% alcoholic chlorhexidine (0·5%) or tetrabrom-o-methyl phenol (0·1%) rubbed on to the hands until they were dry led to mean reduction in viable bacterial counts from standard handwashings of 97·9 ± 1·09% and 91·8 ± 4·63% respectively. After six of such treatments, three on each of two successive days, the mean reductions in relation to viable counts before the first treatment were 99·7 ± 0·09% for alcoholic chlorhexidine and 99·5 ± 0·17% for tetrabrom-o-methyl phenol. These reductions were greater than those obtained with 4% chlorhexidine detergent solution— 87·1 ± 3·5% and 98·2 ± 1·6%, and with 95% or 70% ethyl alcohol and with aqueous 0·5% chlorhexidine. Preoperative washing of the surgeon's hands with alcoholic chlorhexidine used without addition of water is more effective and less expensive than handwashing with antiseptic detergent preparations and running water. The viable counts of washings from hands treated with various antiseptics, including ethyl alcohol, were lower in relation to the pretreatment levels when gloves had been worn for three hours than when samples for counts were taken immediately after the antiseptic treatment. No such difference was found in samplings from hands washed with unmedicated soap. Tests for residual action of antiseptics on the skin showed a greater effect with alcoholic chlorhexidine than with tetrabrom-o-methyl phenol, though both showed greater residual activity than an Irgasan DP 300 detergent preparation. No residual action was shown after 70% ethyl alcohol. PMID:4609555

  13. Efficacy of Instant Hand Sanitizers against Foodborne Pathogens Compared with Hand Washing with Soap and Water in Food Preparation Settings: A Systematic Review.

    PubMed

    Foddai, Antonio C G; Grant, Irene R; Dean, Moira

    2016-06-01

    Hands can be a vector for transmitting pathogenic microorganisms to foodstuffs and drinks, and to the mouths of susceptible hosts. Hand washing is the primary barrier to prevent transmission of enteric pathogens via cross-contamination from infected persons. Conventional hand washing involves the use of water, soap, and friction to remove dirt and microorganisms. The availability of hand sanitizing products for use when water and soap are unavailable has increased in recent years. The aim of this systematic review was to collate scientific information on the efficacy of hand sanitizers compared with washing hands with soap and water for the removal of foodborne pathogens from the hands of food handlers. An extensive literature search was carried out using three electronic databases: Web of Science, Scopus, and PubMed. Twenty-eight scientific publications were ultimately included in the review. Analysis of this literature revealed various limitations in the scientific information owing to the absence of a standardized protocol for evaluating the efficacy of hand products and variation in experimental conditions. However, despite conflicting results, scientific evidence seems to support the historical skepticism about the use of waterless hand sanitizers in food preparation settings. Water and soap appear to be more effective than waterless products for removal of soil and microorganisms from hands. Alcohol-based products achieve rapid and effective inactivation of various bacteria, but their efficacy is generally lower against nonenveloped viruses. The presence of food debris significantly affects the microbial inactivation rate of hand sanitizers.

  14. Multiple faces of contemporary hand knitting

    NASA Astrophysics Data System (ADS)

    Pavko-Čuden, A.

    2017-10-01

    Knitting and crocheting are traditional textile techniques with great significance both in history and modern times. Similar to other textile techniques, knitting has developed into a diversified industrial sector, comprising the production of knitted fabrics, knitwear, hosiery and fashion accessories. At the same time, contemporary knitting and crocheting became hobbies as well as arts-and-crafts activities, extending to various areas of work and leisure. Historical and traditional ethnic knitting and crocheting patterns keep inspiring designers’ collections and also other industrial products. Not so long ago, knitting was seen as an ordinary and unchanging indoor activity and, in its domestic history, it was the preserve of older women making products of dainty work and taste. Today, knitting deals with urban population of all classes. The popularity of leisure hand knitting is increasing; moreover, hand knitting is becoming more and more widespread among young people. With the emergence of artistic and handicraft markets, hand-knitting and crocheting developed into a profitable market activity. Positive effects of hand knitting have become increasingly important - from generating creativity and innovativeness, through knitting and socializing in groups, to medical and therapeutic effects as well as social and global connections. Yarn bombing, yarn storming or graffiti knitting has been used to describe urban social practices of knitted objects placed, or tagged, in public spaces. Knitting became means of communication, artistic and social expression and statement. The advantage of hand knitting is its mobility. One can knit almost everywhere, and for hand knitting, only a ball of yarn and knitting needles are required. Handknitted products have nice touch, they are custom-made and therefore personalized.

  15. Twisted nematic liquid crystal cells with rubbed poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) films for active polarization control of terahertz waves

    NASA Astrophysics Data System (ADS)

    Sasaki, Tomoyuki; Okuyama, Hiroki; Sakamoto, Moritsugu; Noda, Kohei; Okamoto, Hiroyuki; Kawatsuki, Nobuhiro; Ono, Hiroshi

    2017-04-01

    We fabricated a terahertz (THz) polarization converter using a twisted nematic (TN) liquid crystal (LC) cell. Poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) (PEDOT/PSS) films coated on quartz glass substrates were used as electrode layers in the TN LC cell. The PEDOT/PSS films were rubbed unidirectionally using a rayon cloth to align the nematic LC, thereby also serving as an alignment layer. The azimuthal surface anchoring strength of the PEDOT/PSS films was measured to be 5 × 10-4 J/m2 using the Néel wall method, which is similar to that of typical polymeric alignment layers. The optical constants of the PEDOT/PSS film in the THz range were also characterized using the Drude-Smith model, and the results indicated that the PEDOT/PSS films could be used both as transparent electrodes in the THz range and as alignment layers for the LC. The electro-optical properties of the fabricated TN LC cell were also investigated using a polarized visible laser and THz time-domain spectroscopic system. In particular, the transmission spectra and polarization conversion property of the TN LC cell in the THz range were theoretically analyzed based on a stratified model that considers optical anisotropy, absorption, and multiple interference. This work substantiates the advantages of TN LC cells with rubbed PEDOT/PSS films useful for THz polarization converters with electrical tunability.

  16. Effectiveness of a nonrinse, alcohol-free antiseptic hand wash.

    PubMed

    Moadab, A; Rupley, K F; Wadhams, P

    2001-06-01

    This study evaluated the efficacy of a novel surfactant, allantoin, and benzalkonium chloride hand sanitizer using the US Food and Drug Administration's method for testing antiseptic hand washes that podiatric physicians and other health-care personnel use. The alcohol-free product, HandClens, was compared with an alcohol-based product, Purell. Independent researchers from the California College of Podiatric Medicine conducted the study using 40 volunteer students from the class of 2001. The results show that HandClens outperformed Purell and met the regulatory requirements for a hand sanitizer. Purell failed as an antimicrobial hand wash and was less effective than a control soap used in the study.

  17. 7 CFR 2902.18 - Hand cleaners and sanitizers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... use in removing bacteria from human hands with or without the use of water. Personal care products... and bacteria from human hands with or without the use of water are classified as hand sanitizers for...

  18. 7 CFR 2902.18 - Hand cleaners and sanitizers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... use in removing bacteria from human hands with or without the use of water. Personal care products... and bacteria from human hands with or without the use of water are classified as hand sanitizers for...

  19. Increase in hospital purchase of hand hygiene products: The importance of focusing on the right product.

    PubMed

    Biswal, Manisha; Prasad, Amber; Dhaliwal, Navneet; Gupta, A K; Taneja, Neelam

    2015-07-01

    Alcohol-based handrub (AHR) consumption is positively correlated with increases in hand hygiene (HH) compliance. In our 2,000-bed hospital in India, multiple awareness drives have been conducted to promote HH. This study aimed to determine the quantitative effect of these campaigns on use of HH products (soap and AHR) in the hospital. Over the last 6 years, bar soap consumption has increased by 389.15%, whereas that of AHR increased by 146.7%. We also evaluated microbial contamination of 99 bar soap and 60 liquid soap samples in our hospital for a year. Of the samples, 61 (61.6%) of the bar soaps and 2 (3.3%) of the liquid soaps were found to be contaminated with various organisms (P < .0002). To conclude, the focus should be to increase the right kind of HH product so that hospitals in developing countries procure liquid soaps instead of bar soaps for handwashing purposes. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  20. Student Understanding of Cross Product Direction and Use of Right-hand Rules: An Exploration of Representation and Context-dependence

    NASA Astrophysics Data System (ADS)

    Kustusch, Mary Bridget

    2011-12-01

    Students in introductory physics struggle with vector algebra and with cross product direction in particular. Some have suggested that this may be due to misapplied right-hand rules, but there are few studies that have had the resolution to explore this. Additionally, previous research on student understanding has noted several kinds of representation-dependence of student performance with vector algebra in both physics and non-physics (or math) contexts (e.g. Hawkins et al., 2009; Van Deventer, 2008). Yet with few exceptions (e.g. Scaife and Heckler, 2010), these findings have not been applied to cross product direction questions or the use of right-hand rules. Also, the extensive work in spatial cognition is particularly applicable to cross product direction due to the spatial and kinesthetic nature of the right-hand rule. A synthesis of the literature from these various fields reveals four categories of problem features likely to impact the understanding of cross product direction: (1) the type of reasoning required, (2) the orientation of the vectors, (3) the need for parallel transport, and (4) the physics context and features (or lack thereof). These features formed the basis of the present effort to systematically explore the context-dependence and representation- dependence of student performance on cross product direction questions. This study used a mix of qualitative and quantitative techniques to analyze twenty-seven individual think-aloud interviews. During these interviews, second semester introductory physics students answered 80-100 cross product direction questions in different contexts and with varying problem features. These features were then used as the predictors in regression analyses for correctness and response time. In addition, each problem was coded for the methods used and the errors made to gain a deeper understanding of student behavior and the impact of these features. The results revealed a wide variety of methods (including six

  1. Feasibility: An important but neglected issue in patient hand hygiene.

    PubMed

    Knighton, Shanina C; McDowell, Cherese; Rai, Herleen; Higgins, Patricia; Burant, Christopher; Donskey, Curtis J

    2017-06-01

    Patient hand hygiene may be a useful strategy to prevent acquisition of pathogens and to reduce the risk for transmission by colonized patients. Several studies demonstrate that patients and long-term-care facility (LTCF) residents may have difficulty using hand hygiene products that are provided; however, none of them measure feasibility for patients to use different hand hygiene products. A convenience sample of 42 hospitalized patients and 46 LTCF residents was assessed for their ability to use 3 hand sanitizer products (8-oz pushdown pump bottle, 2-oz pocket-sized bottle with a reclosable lid, and alcohol-impregnated hand wipes). The time (seconds) required for accessing each product was compared among acute-care patients and LTCF residents. Participants provided feedback on which product they preferred and found easiest to use. Of 88 participants, 86 (97.7%) preferred the pushdown pump, 2 (2.3%) preferred the bottle with the reclosable lid, and none preferred the hand wipes. For both hospitalized patients and LTCF residents, the average time required to access the pushdown pump was significantly less than the time required to access the other products (pushdown pump, 0.45 seconds; bottle with reclosable lid, 3.86 seconds; and wipes, 5.66 seconds; P < .001). Feasibility and ease of use should be considered in the selection of hand hygiene products for patients and LTCF residents. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. Evaluation of infectious diseases and clinical microbiology specialists' preferences for hand hygiene: analysis using the multi-attribute utility theory and the analytic hierarchy process methods.

    PubMed

    Suner, Aslı; Oruc, Ozlem Ege; Buke, Cagri; Ozkaya, Hacer Deniz; Kitapcioglu, Gul

    2017-08-31

    Hand hygiene is one of the most effective attempts to control nosocomial infections, and it is an important measure to avoid the transmission of pathogens. However, the compliance of healthcare workers (HCWs) with hand washing is still poor worldwide. Herein, we aimed to determine the best hand hygiene preference of the infectious diseases and clinical microbiology (IDCM) specialists to prevent transmission of microorganisms from one patient to another. Expert opinions regarding the criteria that influence the best hand hygiene preference were collected through a questionnaire via face-to-face interviews. Afterwards, these opinions were examined with two widely used multi-criteria decision analysis (MCDA) methods, the Multi-Attribute Utility Theory (MAUT) and the Analytic Hierarchy Process (AHP). A total of 15 IDCM specialist opinions were collected from diverse private and public hospitals located in İzmir, Turkey. The mean age of the participants was 49.73 ± 8.46, and the mean experience year of the participants in their fields was 17.67 ± 11.98. The findings that we obtained through two distinct decision making methods, the MAUT and the AHP, suggest that alcohol-based antiseptic solution (ABAS) has the highest utility (0.86) and priority (0.69) among the experts' choices. In conclusion, the MAUT and the AHP, decision models developed here indicate that rubbing the hands with ABAS is the most favorable choice for IDCM specialists to prevent nosocomial infection.

  3. The first step in infection control is hand hygiene.

    PubMed

    Canham, Leslie

    2011-01-01

    A dental health care worker (DHCW) has an obligation to prevent the spread of health care associated infections. Adhering to proper hand hygiene procedures, selecting appropriate hand hygiene products and the use of gloves are all important elements of infection control. The CDC Guidelines for Hand Hygiene state that improved hand hygiene practices can reduce transmission of pathogenic microorganisms to patients and personnel in health care settings. DHCWs must also protect themselves by recognizing pitfalls such as irritants or allergies that may pose obstacles to proper hand hygiene. Occupational irritants and allergies can be caused by frequent hand washing, exposure to hand hygiene products, exposure to chemicals and shear forces associated with wearing or removing gloves. Since the primary defense against infection and transmission of pathogens is healthy, unbroken skin, DHCWs must take steps to ensure that their skin remains healthy and intact. These steps include evaluating different types of hand hygiene products, lotions and gloves for the best compatibility. If the DHCW sees a breakdown of his or her skin barrier, steps should be taken to determine the cause and remedy. Remedies can include the use of alcohol-based hand sanitizers containing emollients and moisturizers and regular use of a medical grade hand lotion. The bottom line: healthy skin protects you at work and at home. Selection and use of appropriate hand hygiene products, including moisturizers, are an essential part ofa dental office infection control program. My coworker lost the use of her thumb for several months due to complications of a staph infection. She was unable to work and found even simple tasks such as closing a button hard to do. Think of how difficult your work would be if something happened to your hands. Injury, irritation or allergies could alter your ability to work or even perform routine tasks. Our hands provide us with the ability to work in clinical dentistry. It makes

  4. Comparative study of presurgical hand hygiene with hydroalcoholic solution versus traditional presurgical hand hygiene.

    PubMed

    López Martín, M Beatriz; Erice Calvo-Sotelo, Alejo

    To compare presurgical hand hygiene with hydroalcoholic solution following the WHO protocol with traditional presurgical hand hygiene. Cultures of the hands of surgeons and surgical nurses were performed before and after presurgical hand hygiene and after removing gloves at the end of surgery. Cultures were done in 2different days: the first day after traditional presurgical hand hygiene, and the second day after presurgical hand hygiene with hydroalcoholic solution following the WHO protocol. The duration of the traditional hand hygiene was measured and compared with the duration (3min) of the WHO protocol. The cost of the products used in the traditional technique was compared with the cost of the hydroalcoholic solution used. The variability of the traditional technique was determined by observation. Following presurgical hand hygiene with hydroalcoholic solution, colony-forming units (CFU) were detected in 5 (7.3%) subjects, whereas after traditional presurgical hand hygiene CFU were detected in 14 subjects (20.5%) (p < 0.05). After glove removal, the numbers of CFU were similar. The time employed in hand hygiene with hydroalcoholic solution (3min) was inferior to the time employed in the traditional technique (p < 0.05), its cost was less than half, and there was no variability. Compared with other techniques, presurgical hand hygiene with hydroalcoholic solution significantly decreases CFU, has similar latency time, a lower cost, and saves time. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  5. Medicare and Medicaid programs; fire safety requirements for certain health care facilities; amendment. Interim final rule with comment period.

    PubMed

    2005-03-25

    This interim final rule with comment period adopts the substance of the April 15, 2004 temporary interim amendment (TIA) 00-1 (101), Alcohol Based Hand Rub Solutions, an amendment to the 2000 edition of the Life Safety Code, published by the National Fire Protection Association (NFPA). This amendment will allow certain health care facilities to place alcohol-based hand rub dispensers in egress corridors under specified conditions. This interim final rule with comment period also requires that nursing facilities install smoke detectors in resident rooms and public areas if they do not have a sprinkler system installed throughout the facility or a hard-wired smoke detection system in those areas.

  6. Is importing second-hand products a good thing? The cases of computers and tires in Cambodia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chanthy, Lay, E-mail: Lay.Chanthy@ait.ac.th; Nitivattananon, Vilas, E-mail: vilasn@ait.ac.t

    Is importing second-hand products (SHPs) good for Cambodia? To answer this question, one must seriously consider environmental and social effects. The main objective of this study is to identify and assess the economic, social, and environmental impacts of imported SHPs to determine whether or not Cambodia benefits. Imported second-hand computers (SHPCs) and second-hand tires (SHTs) were selected as cases for the study. The study used a scaling checklist to identify significant impacts of these two imported items. Significant impacts were ranked and rated into a single value (score) for integration. Integrated impact assessment showed that imported SHPCs create a verymore » small positive impact (+ 0.1 of + 5) and imported SHTs generate a large negative impact (- 2.83 of - 5). These scores are mainly the result of environmental impact, predominantly waste issues. Thus, current imports of SHPCs and SHTs do not really benefit Cambodia, but instead cause serious environmental problems from their waste issues. The import serves as a channel to transfer waste into developing countries.« less

  7. SaniTwice: a novel approach to hand hygiene for reducing bacterial contamination on hands when soap and water are unavailable.

    PubMed

    Edmonds, Sarah L; Mann, James; McCormack, Robert R; Macinga, David R; Fricker, Christopher M; Arbogast, James W; Dolan, Michael J

    2010-12-01

    The risk of inadequate hand hygiene in food handling settings is exacerbated when water is limited or unavailable, thereby making washing with soap and water difficult. The SaniTwice method involves application of excess alcohol-based hand sanitizer (ABHS), hand "washing" for 15 s, and thorough cleaning with paper towels while hands are still wet, followed by a standard application of ABHS. This study investigated the effectiveness of the SaniTwice methodology as an alternative to hand washing for cleaning and removal of microorganisms. On hands moderately soiled with beef broth containing Escherichia coli (ATCC 11229), washing with a nonantimicrobial hand washing product achieved a 2.86 (±0.64)-log reduction in microbial contamination compared with the baseline, whereas the SaniTwice method with 62 % ethanol (EtOH) gel, 62 % EtOH foam, and 70 % EtOH advanced formula gel achieved reductions of 2.64 ± 0.89, 3.64 ± 0.57, and 4.61 ± 0.33 log units, respectively. When hands were heavily soiled from handling raw hamburger containing E. coli, washing with nonantimicrobial hand washing product and antimicrobial hand washing product achieved reductions of 2.65 ± 0.33 and 2.69 ± 0.32 log units, respectively, whereas SaniTwice with 62 % EtOH foam, 70 % EtOH gel, and 70 % EtOH advanced formula gel achieved reductions of 2.87 ± 0.42, 2.99 ± 0.51, and 3.92 ± 0.65 log units, respectively. These results clearly demonstrate that the in vivo antibacterial efficacy of the SaniTwice regimen with various ABHS is equivalent to or exceeds that of the standard hand washing approach as specified in the U.S. Food and Drug Administration Food Code. Implementation of the SaniTwice regimen in food handling settings with limited water availability should significantly reduce the risk of foodborne infections resulting from inadequate hand hygiene.

  8. Hand-held analyser based on microchip electrophoresis with contactless conductivity detection for measurement of chemical warfare agent degradation products

    NASA Astrophysics Data System (ADS)

    Duran, Karolina-Petkovic; Zhu, Yonggang; Chen, Chuanpin; Swallow, Anthony; Stewart, Robert; Hoobin, Pam; Leech, Patrick; Ovenden, Simon

    2008-12-01

    This paper reports on the development of a hand-held device for on-site detection of organophosphonate nerve agent degradation products. This field-deployable analyzer relies on efficient microchip electrophoresis separation of alkyl methylphosphonic acids and their sensitive contactless conductivity detection. Miniaturized, low-powered design is coupled with promising analytical performance for separating the breakdown products of chemical warfare agents such as Soman, Sarin and VX . The detector has a detection limit of about 10 μg/mL and has a good linear response in the range 10-300 μg/mL concentration range. Applicability to environmental samples is demonstrated .The new hand-held analyzer offers great promise for converting conventional ion chromatography or capillary electrophoresis sophisticated systems into a portable forensic laboratory for faster, simpler and more reliable on-site screening.

  9. Stability of steady hand force production explored across spaces and methods of analysis.

    PubMed

    de Freitas, Paulo B; Freitas, Sandra M S F; Lewis, Mechelle M; Huang, Xuemei; Latash, Mark L

    2018-06-01

    We used the framework of the uncontrolled manifold (UCM) hypothesis and explored the reliability of several outcome variables across different spaces of analysis during a very simple four-finger accurate force production task. Fourteen healthy, young adults performed the accurate force production task with each hand on 3 days. Small spatial finger perturbations were generated by the "inverse piano" device three times per trial (lifting the fingers 1 cm/0.5 s and lowering them). The data were analyzed using the following main methods: (1) computation of indices of the structure of inter-trial variance and motor equivalence in the space of finger forces and finger modes, and (2) analysis of referent coordinates and apparent stiffness values for the hand. Maximal voluntary force and the index of enslaving (unintentional finger force production) showed good to excellent reliability. Strong synergies stabilizing total force were reflected in both structure of variance and motor equivalence indices. Variance within the UCM and the index of motor equivalent motion dropped over the trial duration and showed good to excellent reliability. Variance orthogonal to the UCM and the index of non-motor equivalent motion dropped over the 3 days and showed poor to moderate reliability. Referent coordinate and apparent stiffness indices co-varied strongly and both showed good reliability. In contrast, the computed index of force stabilization showed poor reliability. The findings are interpreted within the scheme of neural control with referent coordinates involving the hierarchy of two basic commands, the r-command and c-command. The data suggest natural drifts in the finger force space, particularly within the UCM. We interpret these drifts as reflections of a trade-off between stability and optimization of action. The implications of these findings for the UCM framework and future clinical applications are explored in the discussion. Indices of the structure of variance and

  10. Field test comparison of two dermal tolerance assessment methods of hand hygiene products.

    PubMed

    Girard, R; Carré, E; Pires-Cronenberger, S; Bertin-Mandy, M; Favier-Bulit, M C; Coyault, C; Coudrais, S; Billard, M; Regard, A; Kerhoas, A; Valdeyron, M L; Cracco, B; Misslin, P

    2008-06-01

    This study aimed to compare the sensitivity and workload requirement of two dermal tolerance assessment methods of hand hygiene products, in order to select a suitable pilot testing method for field tests. An observer-rating method and a self-assessment method were compared in 12 voluntary hospital departments (autumn/winter of 2005-2006). Three test-periods of three weeks were separated by two-week intervals during which the routine products were reintroduced. The observer rating method scored dryness and irritation on four-point scales. In the self-assessment method, the user rated appearance, intactness, moisture content, and sensation on a visual analogue scale which was converted into a 10-point numerical scale. Eleven products (soaps) were tested (223/250 complete reports for observer rating, 131/251 for self-assessment). Two products were significantly less well tolerated than the routine product according to the observers, four products according to the self-assessments. There was no significant difference between the two methods when products were classified according to tolerance (Fisher's test: P=0.491). For the symptom common to both assessment methods (dryness), there is a good correlation between the two methods (Spearman's Rho: P=0.032). The workload was higher for observer rating method (288 h of observer time plus 122 h of prevention team and pharmacist time compared with 15 h of prevention team and pharmacist time for self-assessment). In conclusion, the self-assessment method was considered more suitable for pilot testing, although further time should be allocated for educational measures as the return rate of complete self-assessment forms was poor.

  11. Nursing Care Hour Standards Study. Part 5 thru Part 8

    DTIC Science & Technology

    1981-09-01

    undressing, into shower, with bath and hair shampoo , assist in redressing, and back into the wheelchair. (Must remain with patient and provide assistance...from area. (Buttocks, hips, shoulders , heels.) BACK RUB: Place equipment at patient’s bedside, remove pajama top, 1 turn patient to expose back, rub back...NAIL CARE: Place equipment at bedside, wash hands/feet and 1 nails, trim and clean finger/toe nails, remove equipment from area. SHAMPOO : Place equipment

  12. STOPFLU: is it possible to reduce the number of days off in office work by improved hand-hygiene?

    PubMed Central

    2010-01-01

    Background Acute infectious diseases are major causes of short periods of days off from work, day care and school. These diseases are mainly caused by viruses and hands have a key role in their transmission. Thus, hypothetically, they can be controlled with means of intensified hand hygiene. In this study we aim to elucidate the effect of acute infectious diseases on the work contribution in common office work and study the influence of improved hand hygiene on possible reduction of infectious disease episodes and days off from work due to acute infectious diseases. Design The voluntary participants have been recruited from six companies in the Helsinki region. The designated 21 study clusters were identified as operationally distinct working units each containing at least 50 people. The clusters were matched and randomized based on results of a pre-trial contagion risk survey. Improved hand hygiene is being executed with guided hand-washing with soap and water in one intervention arm and with alcohol based hand rubbing disinfectant in the other. Participants in both arms have received guidance on how to avoid infections and how to implement contagion stopping habits. A control arm is acting as before regarding hand hygiene. Data collection for evaluation of the efficacy of the interventions is based on self-reporting through weekly electronic reports. The questionnaire is enquiring about possible respiratory or gastrointestinal symptoms during the preceding week, and requests a daily report of presence of symptoms and working capacity. Etiology of the symptoms is not searched for individually, but contribution of different viruses is evaluated by sentinel surveillance, where occupational health clinics located in the premises of the participating companies collect specimens from employees visiting the clinic. Common causative agents of the diseases are being searched for using real-time PCR techniques. The duration of the intervention will be 16 months. Primary

  13. Non-contact XUV metrology of Ru/B4C multilayer optics by means of Hartmann wavefront analysis.

    PubMed

    Ruiz-Lopez, Mabel; Dacasa, Hugo; Mahieu, Benoit; Lozano, Magali; Li, Lu; Zeitoun, Philippe; Bleiner, Davide

    2018-02-20

    Short-wavelength imaging, spectroscopy, and lithography scale down the characteristic length-scale to nanometers. This poses tight constraints on the optics finishing tolerances, which is often difficult to characterize. Indeed, even a tiny surface defect degrades the reflectivity and spatial projection of such optics. In this study, we demonstrate experimentally that a Hartmann wavefront sensor for extreme ultraviolet (XUV) wavelengths is an effective non-contact analytical method for inspecting the surface of multilayer optics. The experiment was carried out in a tabletop laboratory using a high-order harmonic generation as an XUV source. The wavefront sensor was used to measure the wavefront errors after the reflection of the XUV beam on a spherical Ru/B 4 C multilayer mirror, scanning a large surface of approximately 40 mm in diameter. The results showed that the technique detects the aberrations in the nanometer range.

  14. Clean Hands for Life: results of a large, multicentre, multifaceted, social marketing hand-hygiene campaign.

    PubMed

    Forrester, L A; Bryce, E A; Mediaa, A K

    2010-03-01

    A year-long multifaceted hand-hygiene campaign entitled Clean Hands for Life targeting individual, environmental and organisational factors that influence healthcare worker (HCW) hand-hygiene behaviour was implemented in 36 acute and long-term care facilities in Vancouver Coastal Health region. The campaign involved rotation of ten novel posters, two poster contests, and distribution of multiple promotional items. A social marketing approach was used to implement and monitor the effectiveness of the campaign. Evaluation included quality assurance surveys, staff surveys (baseline, mid- and post-campaign), and focus groups. A total of 141 poster contest submissions was received, 5452 staff surveys completed and 14 focus groups conducted. Overall knowledge of the importance of hand-hygiene and intention to clean hands was high at baseline. No significant differences were observed when mid- and post-campaign scores were compared to baseline. The majority (89.5%) of HCWs reported that they preferred soap and water over alcohol hand gel. A significant increase in the self-reported use of hand-hygiene products was observed particularly among HCWs not providing direct patient care. Barriers to hand-hygiene included inappropriate placement of sinks, traffic flow issues, inadequately stocked washrooms, workload and time constraints. Organisational support was visible throughout the campaign. The results showed that social marketing is an effective approach in engaging HCWs. Hand-hygiene campaigns that focus almost exclusively on increasing awareness among HCWs may not be as successful as multifaceted campaigns or campaigns that target identified barriers to hand-hygiene. Copyright 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  15. Interventions to improve hand hygiene compliance in patient care.

    PubMed

    Gould, Dinah J; Moralejo, Donna; Drey, Nicholas; Chudleigh, Jane H

    2010-09-08

    Health care-associated infection is a major cause of morbidity and mortality. Hand hygiene is regarded as an effective preventive measure. To update the review done in 2007, to assess the short and longer-term success of strategies to improve hand hygiene compliance and to determine whether a sustained increase in hand hygiene compliance can reduce rates of health care-associated infection. We conducted electronic searches of: the Cochrane Central Register of Controlled Trials; the Cochrane Effective Practice and Organisation of Care Group specialised register of trials; MEDLINE; PubMed; EMBASE; CINAHL; and the BNI. Originally searched to July 2006, for the update databases were searched from August 2006 until November 2009. Randomised controlled trials, controlled clinical trials, controlled before and after studies, and interrupted time series analyses meeting explicit entry and quality criteria used by the Cochrane Effective Practice and Organisation of Care Group were eligible for inclusion. Studies reporting indicators of hand hygiene compliance and proxy indicators such as product use were considered. Self-reported data were not considered a valid measure of compliance. Studies to promote hand hygiene compliance as part of a care bundle approach were included, providing data relating specifically to hand hygiene were presented separately. Studies were excluded if hand hygiene was assessed in simulations, non-clinical settings or the operating theatre setting. Two reviewers independently extracted data and assessed data quality. Four studies met the criteria for the review: two from the original review and two from the update. Two studies evaluated simple education initiatives, one using a randomized clinical trial design and the other a controlled before and after design. Both measured hand hygiene compliance by direct observation. The other two studies were both interrupted times series studies. One study presented three separate interventions within the

  16. Assessing United States Patient and Dermatologist Experiences with Severe Chronic Hand Eczema

    PubMed Central

    Baranowski, Eileen; Zelt, Susan; Reynolds, Maria; Sherrill, Beth

    2015-01-01

    Objective: Patients with severe chronic hand eczema often have persistent symptoms that interfere with daily activities, social functioning, and employment. Many patients are refractory to topical corticosteroids. This survey-based study was performed to characterize treatment experiences, impact on productivity, and quality of life of patients with severe chronic hand eczema; understand dermatologists’ severe chronic hand eczema treatment patterns. Design: A web-based survey in the United States queried pre-identified patients with severe chronic hand eczema regarding symptoms, treatment history, quality of life, work productivity, treatment satisfaction, and healthcare utilization. In a separate survey, dermatologists were asked about treatment patterns and satisfaction with currently available therapies. Results: The most commonly reported symptoms currently experienced by patients (n=163) were dryness/flaking (81%), itchiness (75%), and cracking/tearing of the skin (71%). Over the last three months, 84 percent of patients with severe chronic hand eczema self-reported using topical steroids, and 30 percent used systemic corticosteroids or retinoids. Approximately 30 percent reported impairment while working and productivity loss. Patient quality of life was negatively impacted. Dermatologists (n=125) reported most often treating severe chronic hand eczema with topical corticosteroids (99%), followed by topical immunomodulators (71%) and systemic treatments (70%). Only two percent were very satisfied with currently available products. Conclusion: Patients with severe chronic hand eczema experience symptoms that negatively impact work productivity and quality of life. Few dermatologists are very satisfied with currently available severe chronic hand eczema treatment options. PMID:26705436

  17. Making change easy: A peer-to-peer guide on transitioning to new hand hygiene products.

    PubMed

    Amirov, Chingiz M; Candon, Heather L; Jacob, Latha

    2017-01-01

    This report summarizes our experiences planning and implementing the transition to a new commercial line of hand hygiene products and their dispensing systems in a large academic health care facility in Toronto, Canada. Our lessons learned are organized into a practical guide made available in 2 different formats: this article and an illustrated peer-to-peer guide (http://www.baycrest.org/wp-content/uploads/HCE-PROG-HH_HighQuality.pdf). Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  18. Lean and Green Hand Surgery.

    PubMed

    Van Demark, Robert E; Smith, Vanessa J S; Fiegen, Anthony

    2018-02-01

    Health care in the United States is both expensive and wasteful. The cost of health care in the United States continues to increase every year. Health care spending for 2016 is estimated at $3.35 trillion. Per capita spending ($10,345 per person) is more than twice the average of other developed countries. The United States also leads the world in solid waste production (624,700 metric tons of waste in 2011). The health care industry is second only to the food industry in annual waste production. Each year, health care facilities in the United States produce 4 billion pounds of waste (660 tons per day), with as much as 70%, or around 2.8 billion pounds, produced directly by operating rooms. Waste disposal also accounts for up to 20% of a hospital's annual environmental services budget. Since 1992, waste production by hospitals has increased annually by a rate of at least 15%, due in part to the increased usage of disposables. Reduction in operating room waste would decrease both health care costs and potential environmental hazards. In 2015, the American Association for Hand Surgery along with the American Society for Surgery of the Hand, American Society for Peripheral Nerve Surgery, and the American Society of Reconstructive Microsurgery began the "Lean and Green" surgery project to reduce the amount of waste generated by hand surgery. We recently began our own "Lean and Green" project in our institution. Using "minor field sterility" surgical principles and Wide Awake Local Anesthesia No Tourniquet (WALANT), both surgical costs and surgical waste were decreased while maintaining patient safety and satisfaction. As the current reimbursement model changes from quantity to quality, "Lean and Green" surgery will play a role in the future health care system. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  19. Handwashing practices and challenges in Bangladesh.

    PubMed

    Hoque, B A

    2003-06-01

    Handwashing is universally promoted in health interventions. Studies in Bangladesh and elsewhere have shown a 14 - 40% reduction of diarrhoeal diseases with handwashing. The perceptions and methods related to washing of hands vary widely in Bangladesh. Socio-economic factors are also associated with methods practised. In general, the effectiveness of handwashing practices is poor. Faecal coliform bacteriological counts were reported to be high for both left and right hands. About 85% of women studied who lived in slums and 41% of rural women washed their hands using only water. However, most women rubbed their hands on the ground, or used soil, and rinsed them with water during post-defecation handwashing. Most women claimed that they could not afford to buy soap. Experimental trials showed that use of soap, ash or soil gave similar results when women washed their hands under the same conditions. The washing of both hands, rubbing of hands, and the amount and quality of rinsing water used were found to be important determinants in the reduction of bacterial counts on hands. Although handwashing messages have been revised by most of the main programmes after these studies, there is scope for further improvement, as well as evaluation of their impact.

  20. Hand washing frequencies and procedures used in retail food services.

    PubMed

    Strohbehn, Catherine; Sneed, Jeannie; Paez, Paola; Meyer, Janell

    2008-08-01

    Transmission of viruses, bacteria, and parasites to food by way of improperly washed hands is a major contributing factor in the spread of foodborne illnesses. Field observers have assessed compliance with hand washing regulations, yet few studies have included consideration of frequency and methods used by sectors of the food service industry or have included benchmarks for hand washing. Five 3-h observation periods of employee (n = 80) hand washing behaviors during menu production, service, and cleaning were conducted in 16 food service operations for a total of 240 h of direct observation. Four operations from each of four sectors of the retail food service industry participated in the study: assisted living for the elderly, childcare, restaurants, and schools. A validated observation form, based on 2005 Food Code guidelines, was used by two trained researchers. Researchers noted when hands should have been washed, when hands were washed, and how hands were washed. Overall compliance with Food Code recommendations for frequency during production, service, and cleaning phases ranged from 5% in restaurants to 33% in assisted living facilities. Procedural compliance rates also were low. Proposed benchmarks for the number of times hand washing should occur by each employee for each sector of food service during each phase of operation are seven times per hour for assisted living, nine times per hour for childcare, 29 times per hour for restaurants, and 11 times per hour for schools. These benchmarks are high, especially for restaurant employees. Implementation would mean lost productivity and potential for dermatitis; thus, active managerial control over work assignments is needed. These benchmarks can be used for training and to guide employee hand washing behaviors.

  1. Kaiser Permanente National Hand Hygiene Program

    PubMed Central

    Barnes, Sue; Barron, Dana; Becker, Linda; Canola, Teresa; Salemi, Charles

    2004-01-01

    Objective: Hand hygiene has historically been identified as an important intervention for preventing infection acquired in health care settings. Recently, the advent of waterless, alcohol-based skin degermer and elimination of artificial nails have been recognized as other important interventions for preventing infection. Supplied with this information, the National Infection Control Peer Group convened a KP Hand Hygiene Work Group, which, in August 2001, launched a National Hand Hygiene Program initiative titled “Infection Control: It’s In Our Hands” to increase compliance with hand hygiene throughout the Kaiser Permanente (KP) organization. Design: The infection control initiative was designed to include employee and physician education as well as to implement standard hand hygiene products (eg, alcohol degermers), eliminate use of artificial nails, and monitor outcomes. Results: From 2001 through September 2003, the National KP Hand Hygiene Work Group coordinated implementation of the Hand Hygiene initiative throughout the KP organization. To date, outcome monitoring has shown a 26% increase in compliance with hand hygiene as well as a decrease in the number of bloodstream infections and methycillin-resistant Staphylococcus aureus (MRSA) infections. As of May 2003, use of artificial nails had been reduced by 97% nationwide. Conclusions: Endorsement of this Hand Hygiene Program initiative by KP leadership has led to implementation of the initiative at all medical centers throughout the KP organization. Outcome indicators to date suggest that the initiative has been successful; final outcome monitoring will be completed in December 2003. PMID:26704605

  2. Hesitation and error: Does product placement in an emergency department influence hand hygiene performance?

    PubMed

    Stackelroth, Jenny; Sinnott, Michael; Shaban, Ramon Z

    2015-09-01

    Existing research has consistently demonstrated poor compliance by health care workers with hand hygiene standards. This study examined the extent to which incorrect hand hygiene occurred as a result of the inability to easily distinguish between different hand hygiene solutions placed at washbasins. A direct observational method was used using ceiling-mounted, motion-activated video camera surveillance in a tertiary referral emergency department in Australia. Data from a 24-hour period on day 10 of the recordings were collected into the Hand Hygiene-Technique Observation Tool based on Feldman's criteria as modified by Larson and Lusk. A total of 459 episodes of hand hygiene were recorded by 6 video cameras in the 24-hour period. The observed overall rate of error in this study was 6.2% (27 episodes). In addition an overall rate of hesitation was 5.8% (26 episodes). There was no statistically significant difference in error rates with the 2 hand washbasin configurations. The amelioration of causes of error and hesitation by standardization of the appearance and relative positioning of hand hygiene solutions at washbasins may translate in to improved hand hygiene behaviors. Placement of moisturizer at the washbasin may not be essential. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  3. The fragrance hand immersion study - an experimental model simulating real-life exposure for allergic contact dermatitis on the hands.

    PubMed

    Heydorn, S; Menné, T; Andersen, K E; Bruze, M; Svedman, C; Basketter, D; Johansen, J D

    2003-06-01

    Recently, we showed that 10 x 2% of consecutively patch-tested hand eczema patients had a positive patch test to a selection of fragrances containing fragrances relevant to hand exposure. In this study, we used repeated skin exposure to a patch test-positive fragrance allergen in patients previously diagnosed with hand eczema to explore whether immersion of fingers in a solution with or without the patch-test-positive fragrance allergen would cause or exacerbate hand eczema on the exposed finger. The study was double blinded and randomized. All participants had a positive patch test to either hydroxycitronellal or Lyral (hydroxyisohexyl 3-cyclohexene carboxaldehyde). Each participant immersed a finger from each hand, once a day, in a solution containing the fragrance allergen or placebo. During the first 2 weeks, the concentration of fragrance allergen in the solution was low (approximately 10 p.p.m.), whilst during the following 2 weeks, the concentration was relatively high (approximately 250 p.p.m.), imitating real-life exposure to a household product like dishwashing liquid diluted in water and the undiluted product, respectively. Evaluation was made using a clinical scale and laser Doppler flow meter. 3 of 15 hand eczema patients developed eczema on the finger immersed in the fragrance-containing solution, 3 of 15 on the placebo finger and 3 of 15 on both fingers. Using this experimental exposure model simulating real-life exposure, we found no association between immersion of a finger in a solution containing fragrance and development of clinically visible eczema on the finger in 15 participants previously diagnosed with hand eczema and with a positive patch test to the fragrance in question.

  4. Rub tolerance evaluation of two sintered NiCrAl gas path seal materials. [wear tests of gas turbine engine seals

    NASA Technical Reports Server (NTRS)

    Bill, R. C.

    1978-01-01

    Two strength level variations of sintered NiCrAl (about 40 percent dense), candidate high pressure turbine seal materials, were subject to rub tolerance testing against AM 355 steel blade tips. The high strength material (17 N/sq mm tensile strength) showed frictional and radial loads that were 20 to 50 percent higher than those measured for the low strength material (15.5 N/ sq mm tensile strength). Measured wear to the AM 355 blade tips was not significantly different for the two sintered NiCrAl seal materials. Wear of the sintered NiCrAl was characterized by material removal to a depth greater than the depth to which blade tips were driven into the seal, indicating self-erosion effects.

  5. Microbial Efficacy of Waterless Hand Hygiene in Dar es Salaam, Tanzania

    NASA Astrophysics Data System (ADS)

    Pickering, A.; Boehm, A.; Davis, J.

    2008-12-01

    Millions of people die from diarrheal and respiratory diseases every year due to lack of proper sanitation, hygiene, and access to clean water. The act of handwashing with soap has been found to effectively reduce both diarrheal and respiratory illness, however, handwashing at critical times (i.e. after using the toilet, before preparing food) remains infrequent around the world. This research investigates the potential for alcohol- based hand sanitizer (ABHS) to be an effective and appropriate hand hygiene option in developing countries. A study was conducted to assess the microbiological effectiveness of ABHS, as compared to handwashing with soap and water, in field conditions in Dar es Salaam, Tanzania. A total of 205 participants, including mothers, nurses, students, and teachers, were introduced to ABHS, given a standardized amount (2ml) of product, and instructed on how to use the product correctly. Hand samples were obtained using the hand rinse method before and after the use of ABHS from 152 participants. The other 53 participants were hand sampled before and after handwashing with a non-antimicrobial liquid soap and clean water (prior to using ABHS). Visual inspections of the hands were performed before hand sampling to record the level of dirt on the hands. All hand samples were processed and analyzed by membrane filtration for concentrations of two microbial indicators, enterococci and E. coli. User perceptions of the product and willingness to pay are also documented. The results of this study provide valuable insight on the prospective of promoting ABHS in developing countries and water scarce areas.

  6. Baseline evaluation of hand hygiene compliance in three major hospitals, Isfahan, Iran.

    PubMed

    Ataei, B; Zahraei, S M; Pezeshki, Z; Babak, A; Nokhodian, Z; Mobasherizadeh, S; Hoseini, S G

    2013-09-01

    Hand hygiene is the mainstay of nosocomial infection prevention. This study was a baseline survey to assess hand hygiene compliance of healthcare workers by direct observation in three major hospitals of Isfahan, Iran. The use of different hand hygiene products was also evaluated. In 3078 potential opportunities hand hygiene products were available on 2653 occasions (86.2%). Overall compliance was 6.4% (teaching hospital: 7.4%; public hospital: 6.2%; private hospital: 1.4%). Nurses (8.4%) had the highest rates of compliance. Poor hand hygiene compliance in Isfahan hospitals necessitates urgent interventions to improve both hospital infrastructure and staff knowledge. © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  7. Mentor's hand hygiene practices influence student's hand hygiene rates.

    PubMed

    Snow, Michelle; White, George L; Alder, Stephen C; Stanford, Joseph B

    2006-02-01

    There were 3 objectives for this prospective quasiexperimental study. The first was to determine the effect of mentor's hand hygiene practices on student's hand hygiene rates during clinical rotations. The second was to assess the difference in hand hygiene rates for students with and without prior medical experience. The third was to assess the student's opinion and beliefs regarding hand hygiene. Sixty students enrolled in a certified nursing program were selected to participate in the study. Each study group was observed twice during the 30-day span. The first observational period was conducted on day 1 of clinical rotation. The second observational period was conducted on day 30 of clinical rotation. Students were observed for hand hygiene. Also assessed were medical experience, sex, gloving, age, and mentor's hand hygiene practices. After observational period 2, a brief questionnaire was given to students to determine their opinion and beliefs regarding hand hygiene. The questionnaire was divided into 5 sections: student's commitment to hand hygiene, their perception of hand hygiene inconvenience, the necessity of hand hygiene, the student's ability to perform hand hygiene, and their opinion on the frequency of medical staff's hand hygiene. The mentor's practice of hand hygiene was the strongest predictor of the student's rate of hand hygiene for both observational periods (P < .01). Furthermore, students without prior medical experience had a significant increase in hand hygiene rates when comparing observational period 1 to observational period 2 (P < .01). Glove usage was associated with increased hand hygiene rates by 50% during observational period 1 (P = .01) and 44% during observational period 2 (P < .01). Male students during observational period 1 practiced hand hygiene 30% less often than female students (P < .01); however, during observational period 2, there was no significant difference between hand hygiene rates for males and females (P = .82

  8. Medicare and Medicaid programs; fire safety requirements for certain health care facilities; amendment. Final rule.

    PubMed

    2006-09-22

    This final rule adopts the substance of the April 15, 2004 tentative interim amendment (TIA) 00-1 (101), Alcohol Based Hand Rub Solutions, an amendment to the 2000 edition of the Life Safety Code, published by the National Fire Protection Association (NFPA). This amendment allows certain health care facilities to place alcohol-based hand rub dispensers in egress corridors under specified conditions. This final rule also requires that nursing facilities at least install battery-operated single station smoke alarms in resident rooms and common areas if they are not fully sprinklered or they do not have system-based smoke detectors in those areas. Finally, this final rule confirms as final the provisions of the March 25, 2005 interim final rule with changes and responds to public comments on that rule.

  9. Rapid and simple immunochemical screening combined with hand-shaking extraction for thiamethoxam residue in agricultural products.

    PubMed

    Watanabe, Eiki; Kobara, Yuso; Miyake, Shiro

    2013-06-01

    With the aim of expanding the applicability of a kit-based enzyme-linked immunosorbent assay (ELISA) for the neonicotinoid insecticide thiamethoxam, the ELISA was newly applied to three kinds of agricultural samples (green pepper, eggplant and spinach). To offer the ELISA as a screening analysis for thiamethoxam residues, a rapid and simple method of extraction by hand-shaking was used, and speed-up and simplification of the sample treatment before the ELISA analysis were examined. Finally, the validity of the ELISA combined with the proposed extraction method was verified against a reference high-performance liquid chromatography (HPLC) method using real-world agricultural samples. There were no marked matrix effects derived from green pepper and eggplant extracts. On the other hand, although the effect due to a pigment in spinach extract on the assay performance was significant, it was effectively avoided by increasing the dilution level of the spinach extract. For thiamethoxam-spiked samples, acceptable recoveries of 97.9-109.1% and coefficients of variation of 0.3-11.5% were obtained. Inspection of the validity of the ELISA by comparison with the reference HPLC method showed that the two analytical results were very similar, and a high correlation was found between them (r>0.997). The evaluated ELISA combined with hand-shaking extraction provided a rapid and simple screening analysis that was quantitative and reliable for the detection of thiamethoxam in complex agricultural products. © 2012 Society of Chemical Industry.

  10. The effect of hand hygiene on illness rate among students in university residence halls.

    PubMed

    White, Cindy; Kolble, Robin; Carlson, Rebecca; Lipson, Natasha; Dolan, Mike; Ali, Yusuf; Cline, Mojee

    2003-10-01

    Several studies have indicated a connection between hand sanitization and infection control in numerous settings such as extended care facilities, schools, and hospitals. The purpose of this study was to assess the effectiveness of both a hand-hygiene message campaign and the use of an alcohol gel hand sanitizer in decreasing the incidence of upper-respiratory illness among students living in university residence halls. This study involved a total of 430 students recruited from 4 residence halls during the fall semester at the University of Colorado at the Boulder campus. Dormitories were paired into control and product groups. In the product groups, alcohol gel hand-sanitizer dispensers were installed in every room, bathroom, and dining hall. The data were statistically analyzed for the differences between product and control groups in reported symptoms, illness rates, and absenteeism from classes. The overall increase in hand-hygiene behavior and reduction in symptoms, illness rates, and absenteeism between the product group and control group was statistically significant. Reductions in upper respiratory-illness symptoms ranged from 14.8% to 39.9%. Total improvement in illness rate was 20%. The product group had 43% less missed school/work days. Hand-hygiene practices were improved with increased frequency of handwashing through increasing awareness of the importance of hand hygiene, and the use of alcohol gel hand sanitizer in university dormitories. This resulted in fewer upper respiratory-illness symptoms, lower illness rates, and lower absenteeism.

  11. Nail-Gun Injuries to the Hand

    PubMed Central

    Pierpont, Yvonne N.; Pappas-Politis, Effie; Naidu, Deepak K.; Salas, R. Emerick; Johnson, Erika L.; Payne, Wyatt G.

    2008-01-01

    Background: The nail gun is a commonly utilized tool in carpentry and construction. When used properly with appropriate safety precautions, it can facilitate production and boost efficiency; however, this powerful tool also has the potential to cause serious injury. The most common site of nail-gun injuries in both industrial and nonoccupational settings is the hand. Materials and Methods: We report on two patients with nail-gun injuries to the hand. A review of the literature and discussion of clinical evaluation and treatment of nail-gun injuries to the hand are presented. Results: Two patients present with soft tissue injuries to the hand with the nail embedded and intact at the injury site. Operative removal of the nail and wound care resulted in successful treatment in both cases. Nail-gun injuries to the hand vary in severity on the basis of the extent of structural damage. Treatment is based on the severity of injury and the presence and location of barbs on the penetrating nail. Conclusion: Healthcare providers must understand and educate patients on the prevention mechanics of nail-gun injuries. Nail-gun injuries to the hand necessitate appropriate evaluation techniques, understanding of surgical management versus nonsurgical management, and awareness of potential pitfalls in treatment. PMID:19079574

  12. 46 CFR 160.048-6 - Marking.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... waterproof so that after 72 hours submergence in water, it will withstand vigorous rubbing by hand while wet.... Inspected and tested in accordance with U.S. Coast Guard regulations. Dry out thoroughly when wet. (Kapok or...

  13. 46 CFR 160.048-6 - Marking.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... waterproof so that after 72 hours submergence in water, it will withstand vigorous rubbing by hand while wet.... Inspected and tested in accordance with U.S. Coast Guard regulations. Dry out thoroughly when wet. (Kapok or...

  14. 46 CFR 160.048-6 - Marking.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... waterproof so that after 72 hours submergence in water, it will withstand vigorous rubbing by hand while wet.... Inspected and tested in accordance with U.S. Coast Guard regulations. Dry out thoroughly when wet. (Kapok or...

  15. 46 CFR 160.048-6 - Marking.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... waterproof so that after 72 hours submergence in water, it will withstand vigorous rubbing by hand while wet.... Inspected and tested in accordance with U.S. Coast Guard regulations. Dry out thoroughly when wet. (Kapok or...

  16. Optimization of greenhouse gas emissions in second-hand consumer product recovery through reuse platforms.

    PubMed

    Fortuna, Lorena M; Diyamandoglu, Vasil

    2017-08-01

    Product reuse in the solid waste management sector is promoted as one of the key strategies for waste prevention. This practice is considered to have favorable impact on the environment, but its benefits have yet to be established. Existing research describes the perspective of "avoided production" only, but has failed to examine the interdependent nature of reuse practices within an entire solid waste management system. This study proposes a new framework that uses optimization to minimize the greenhouse gas emissions of an integrated solid waste management system that includes reuse strategies and practices such as reuse enterprises, online platforms, and materials exchanges along with traditional solid waste management practices such as recycling, landfilling, and incineration. The proposed framework uses material flow analysis in combination with an optimization model to provide the best outcome in terms of GHG emissions by redistributing product flows in the integrated solid waste management system to the least impacting routes and processes. The optimization results provide a basis for understanding the contributions of reuse to the environmental benefits of the integrated solid waste management system and the exploration of the effects of reuse activities on waste prevention. A case study involving second-hand clothing is presented to illustrate the implementation of the proposed framework as applied to the material flow. Results of the case study showed the considerable impact of reuse on GHG emissions even for small replacement rates, and helped illustrate the interdependency of the reuse sector with other waste management practices. One major contribution of this study is the development of a framework centered on product reuse that can be applied to identify the best management strategies to reduce the environmental impact of product disposal and to increase recovery of reusable products. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Friction and wear of several compressor gas-path seal movements

    NASA Technical Reports Server (NTRS)

    Bill, R. C.; Wisander, D. W.

    1978-01-01

    Rub interaction experiments were conducted on a series of sintered and plasma sprayed compressor gas path seal materials in contact with Ti-6Al-4V blade tip and knife edge rotors. The most rub tolerant materials investigated were sintered Nichrome and plasma sprayed nickel 25 percent graphite. The effectiveness of providing a compliant substrate for dense seal material coatings was also demonstrated. In general, it was observed that rotor wear and high frictional energy generation rates accompanied smearing or surface densification of the materials investigated. The onset of smearing was sensitive to rub interaction parameters and seal geometry. Two complementary models were proposed to account for the smearing trends. One is based on thermal effects, the other on particulate escape effects. They were shown to be consistent with the experimental evidence at hand, and together they predict that smearing, with the onset of high energy rub conditions, is favored when incursion rates (radial motion) are low, incursion depths are high, the seal geometry is of a knife-edge character, and the seal particle size is small.

  18. Improving agricultural straw preparation logistics stream in bio-methane production: experimental studies and application analysis.

    PubMed

    Tao, Luo; Junting, Pan; Xi, Meng; Hailong, Huang; Yan, Long; Xia, Xiong; Ruyi, Huang; Zili, Mei

    2017-10-01

    Long-term production in commercial straw biogas plants has been rare in China due to inefficiencies in the logistics stream. Biomass densification could be a potential solution to this issue. Therefore, we conducted a study to evaluate whether biomass densification is a more efficient and sustainable option. We performed methane production experiments to investigate fermentation characteristics of briquettes (with a new pretreatment, model II) and rubs (with a common pretreatment, model I). A 3000-m 3 biogas plant was used to conduct a comparative analysis with solar eMergy joules. Results showed that the methane yield of briquettes of corn stover was 66.74% higher than that of rubs, and the briquettes had better digestion performance in terms of CH 4 content, VFA, and alcohol. The two models required almost the same eMergy investment input, while model II obtained a greater quantity of net eMergy (16.5% higher) in comparison with model I. The net eMergy yield ratio (EYR) (biogas only) of model I and model II was 0.99 and 1.67, respectively, showing less market competitiveness for commercial operations with model I. Meanwhile, the logistic costs of model II could be reduced to approximately US $34,514 annually.

  19. Hand preference and skilled hand performance among individuals with successful rightward conversions of the writing hand.

    PubMed

    Porac, Clare

    2009-03-01

    Searleman and Porac (2001) studied lateral preference patterns among successfully switched left-hand writers, left-hand writers with no switch pressure history, and left-hand writers who did not switch when pressured. They concluded that left-handers who successfully shift to right-hand writing are following an inherent right-sided lateralisation pattern that they already possess. Searleman and Porac suggested that the neural mechanisms that control lateralisation in the successfully switched individuals are systematically different from those of other groups of left-handers. I examined patterns of skilled and less-skilled hand preference and skilled hand performance in a sample of 394 adults (ages 18-94 years). The sample contained successfully switched left-hand writers, left-handers pressured to shift who remained left-hand writers, left-handers who did not experience shift pressures, and right-handers. Both skilled hand preference and skilled hand performance were shifted towards the right side in successfully switched left-hand writers. This group also displayed mixed patterns of hand preference and skilled hand performance in that they were not as right-sided as "natural" right-handers nor were they as left-sided as the two left-hand writing groups, which did not differ from each other. The experience of being pressured to switch to right-hand writing was not sufficient to shift lateralisation patterns; the pressures must be experienced in the context of an underlying neural control mechanism that is amenable to change as a result of these external influences.

  20. Testing a new alcohol-free hand sanitizer to combat infection.

    PubMed

    Dyer, D L; Gerenraich, K B; Wadhams, P S

    1998-08-01

    Universal precautions require that perioperative health care personnel wash their hand before and after all patient contact. Time constraints, however, can make adhering to universal precautions, including proper hand washing, difficult. Some perioperative health care workers, therefore, routinely use rise-free hand sanitizers to supplement normal hand washing. This study evaluated immediate and persistent antimicrobial effectiveness of two alcohol--containing hand sanitizers and a novel surfactant, allantoin, benzalkonium chloride (SAB) hand sanitizer using a federally approved effectiveness protocol. Results indicate that all three products were equally effective after a single application. After repeated use, the alcohol-containing sanitizers did not meet federal performance standards, and the alcohol-free sanitizer did. These properties and others illustrated in this article indicate that the nonflammable, alcohol-free SAB hand sanitizer is the most favorable of the rise-free hand sanitizer formulas for normal hand washing.

  1. [Does the hand solely belong in the hands of a qualified hand surgeon?

    PubMed

    Güven, Asim; Kols, Kerstin; Fischer, Klaus; Schönberger, Michael; Allert, Sixtus

    2017-09-01

    Background In Germany, Hand Surgery is an additional qualification that can only be obtained by a three-year training after a completed residency in General Surgery, Plastic Surgery or Trauma and Orthopaedic Surgery. Nevertheless, injuries and diseases of the hand are also treated by physicians without this particular qualification. It is questionable whether these treatments more often lead to medical malpractice. Material and Methods 376 charges of medical malpractice in surgical treatments of the hand and forearm that were closed in 2014 and 2015 were collected by the Arbitration Board for Medical Liability Issues of the Medical Association of North Germany.Cases with proven medical malpractice were classified by the qualification of the physician in charge and analysed. A statistical analysis was performed with the use of the program SPSS (IBM). Results Medical malpractice was proven in 42 of 113 cases with an attending physician who held the additional qualification for Hand Surgery (37.2 %). For physicians without this qualification, the figures were 79 out of 155 (51.0 %) in the group of trauma and orthopaedic surgeons and 54 out of 108 (50.0 %) in the group of general surgeons. The differences between the hand surgeons and the trauma and orthopaedic surgeons (p = 0.017) and between hand surgeons and general surgeons were significant (p = 0.037). Conclusions It was shown that physicians with an additional qualification in hand surgery had signifcantly fewer proven medical malpratice cases than physicians without this qualification. The following trends were observed in the cases of the physicians without the additional qualification in hand surgery: underestimation of the severity of trauma to soft tissues and infections of the hand, errors in the surgical examination of the hand, including functional tests of tendons and nerves, as well as in diagnostic findings after X-ray studies of the hand. Georg Thieme Verlag KG Stuttgart · New York.

  2. Hand safety for specialty crop production workers: a pilot study investigating frequencies of minor open-wound hand injuries and presence of pathogenic bacteria.

    PubMed

    Pate, M L; Nummer, B

    2013-10-01

    The purpose of this study was to quantify the presence of minor open-wound hand injuries in addition to Salmonella, Staphylococcus aureus, coliforms, and Escherichia coli on the hands of farm workers who hand-harvest fruit crops in Utah. Data collection was conducted on four farms without USDA Good Agricultural Practices (GAP) certification and on two farms with GAP certification. This study identified essential safety issues that need to be addressed for improving the effectiveness of safety training for migrant farm workers. Farms that have a food safety audit program in place are less likely to have farm workers exposed to pathogenic bacteria and open-wound injuries to their hands. High frequency of S. aureus may indicate a potentially higher risk for wound infection within this worker population. This could lead to infections that are resistant to the antibiotics commonly used to treat ordinary staph infections, resulting in greater work loss time and medical expenses for these workers. Higher frequencies of bacterial presence on workers' hands on non-certified farms indicate a need to identify essential practices to improve worker hygiene habits and on-farm management practices to promote healthy hygiene. Open-wound injuries to migrant farm workers during hand-harvesting could create additional health problems with the possibility of infection and the spread of diseases. Continued research is needed to understand workers' acceptance of these injuries and barriers to personal protection.

  3. 46 CFR 160.060-8 - Marking.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... waterproof so that after 72 hours submergence in water it will withstand vigorous rubbing by hand while wet... of (151/2 lb., 11 lb., or 7 lb.). Dry out thoroughly when wet. Approved for use on all recreational...

  4. What's growing on your stethoscope? (And what you can do about it).

    PubMed

    Schroeder, Ariel; Schroeder, Maryellen A; D'Amico, Frank

    2009-08-01

    Studies have shown that rubbing alcohol pads on stethoscope diaphragms can reduce bacterial colonization, but alcohol pads are used infrequently used and not always available. We conducted a prospective, single-blinded study to investigate whether simultaneously scrubbing hands and stethoscope head with alcohol-based hand foam would significantly reduce bacterial counts on the stethoscope. Using their own stethoscope, participants imprinted the stethoscope head onto a chocolate agar plate, then used alcohol-based hand foam to cleanse their hands while simultaneously rubbing the stethoscope head. Once the stethoscope heads were dry, the participants imprinted their stethoscope heads onto a second plate. After 48 hours' incubation, we determined the bacterial counts for the prewash and post-wash plates, and compared the 2. We analyzed a total of 184 cultures (from 92 stethoscopes). Both the mean (28 prewash vs 3 post-wash, P=.001) and median (11 prewash vs 1 post-wash, P=.001) colony counts were significantly greater before being cleansed. Three methicillin-resistant Staphylococcus aureus (MRSA) colonies were identified in the prewash period; all were destroyed by the foam. The estimated number of hand washes needed to prevent 1 MRSA colony is 31 (95% confidence interval [CI], 18-89). Simultaneously using hand foam to clean hands and stethoscope heads reduces bacterial counts on stethoscopes. Further research is needed to determine whether this intervention can reduce morbidity and mortality associated with bacterial infection.

  5. The Influence of Temperature on the Frictional Behavior of Duplex-Coated Die Steel Rubbing Against Forging Brass

    NASA Astrophysics Data System (ADS)

    Ebrahimzadeh, I.; Ashrafizadeh, F.

    2015-01-01

    Improvement of die life under hot forging of brass alloys is considered vital from both economical and technical points of view. One of the best methods for improving die life is duplex coatings. In this research, the influence of temperature on the tribological behavior of duplex-coated die steel rubbing against forging brass was investigated. The wear tests were performed on a pin-on-disk machine from room temperature to 700 °C; the pins were made in H13 hot work tool steel treated by plasma nitriding and by PVD coatings of TiN-TiAlN-CrAlN. The disks were machined from a two-phase brass alloy too. The results revealed that the friction coefficient of this tribosystem went through a maximum at 550 °C and decreased largely at 700 °C. Furthermore, the formation of Cr2O3 caused the reduction of friction coefficient at 700 °C. PVD coatings proved their wear resistance up to 550 °C, well above the working temperature of the brass forging dies.

  6. The Rubella Virus Nonstructural Protease Requires Divalent Cations for Activity and Functions in trans

    PubMed Central

    Liu, Xin; Ropp, Susan L.; Jackson, Richard J.; Frey, Teryl K.

    1998-01-01

    The rubella virus (RUB) nonstructural (NS) protease is a papain-like cysteine protease (PCP) located in the NS-protein open reading frame (NSP-ORF) that cleaves the NSP-ORF translation product at a single site to produce two products, P150 (the N-terminal product) and P90 (the C-terminal product). The RUB NS protease was found not to function following translation in vitro in a standard rabbit reticulocyte lysate system, although all of the other viral PCPs do so. However, in the presence of divalent cations such as Zn2+, Cd2+, and Co2+, the RUB NS protease functioned efficiently, indicating that these cations are required either as direct cofactors in catalytic activity or for correct acquisition of three-dimensional conformation of the protease. Since other viral and cell PCPs do not require cations for activity and the RUB NS protease contains a putative zinc binding motif, the latter possibility is more likely. Previous in vivo expression studies of the RUB NS protease failed to demonstrate trans cleavage activity (J.-P. Chen et al., J. Virol. 70:4707–4713, 1996). To study whether trans cleavage could be detected in vitro, a protease catalytic site mutant and a mutant in which the C-terminal 31 amino acids of P90 were deleted were independently introduced into plasmid constructs that express the complete NSP-ORF. Cotranslation of these mutants in vitro yielded both the native and the mutated forms of P90, indicating that the protease present in the mutated construct cleaved the catalytic-site mutant precursor. Thus, RUB NS protease can function in trans. PMID:9557742

  7. Routine hand hygiene audit by direct observation: has nemesis arrived?

    PubMed

    Gould, D J; Drey, N S; Creedon, S

    2011-04-01

    Infection prevention and control experts have expended valuable health service time developing and implementing tools to audit health workers' hand hygiene compliance by direct observation. Although described as the 'gold standard' approach to hand hygiene audit, this method is labour intensive and may be inaccurate unless performed by trained personnel who are regularly monitored to ensure quality control. New technological devices have been developed to generate 'real time' data, but the cost of installing them and using them during routine patient care has not been evaluated. Moreover, they do not provide as much information about the hand hygiene episode or the context in which hand hygiene has been performed as direct observation. Uptake of hand hygiene products offers an inexpensive alternative to direct observation. Although product uptake would not provide detailed information about the hand hygiene episode or local barriers to compliance, it could be used as a continuous monitoring tool. Regular inspection of the data by infection prevention and control teams and clinical staff would indicate when and where direct investigation of practice by direct observation and questioning of staff should be targeted by highly trained personnel to identify local problems and improve practice. Copyright © 2011 the Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  8. Surgical hand preparation with chlorhexidine soap or povidone iodine: new methods to increase immediate and residual effectiveness, and provide a safe alternative to alcohol solutions.

    PubMed

    Herruzo, R; Vizcaino, M J; Yela, R

    2018-04-01

    Surgical use of 4% chlorhexidine soap (CHX-4) and 10% povidone iodine (PVP-I-10) does not meet the standards defined by EN 12791. To investigate the possibility of increasing the immediate and residual effects of these antiseptics. Over three consecutive weeks, n-propanol, standard CHX-4 and PVP-I-10 were tested in two experimental groups of volunteers. The new method for applying the antiseptic substances involved standard hand rub and rinse of CHX-4 or PVP-I-10, followed by application of an aqueous solution based on 5% chlorhexidine or PVP-I-10 with no further rinsing of the hands prior to donning gloves. Samples were taken to assess immediate and residual effects, analysing the logarithmic reduction of colony-forming units. At t=0 h, n-propanol was superior in bactericidal effect to standard CHX-4 (P<0.05), but the new chlorhexidine protocol was superior to both standard CHX-4 (P<0.01) and n-propanol (P<0.05); the same effect was observed at t=3 h (residual effect). At t=0 h, n-propanol was significantly superior to standard PVP-I-10, but the new PVP-I-10 protocol was superior, although not significantly, to n-propanol. There was no significant residual effect at t=3 h. The new protocol for chlorhexidine application permits surgical hand preparation with chlorhexidine, as a safe alternative to alcohol solutions, because it meets the standards defined by EN 12791. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. Significance of palpable tendon friction rubs in early diffuse cutaneous systemic sclerosis.

    PubMed

    Doré, Adam; Lucas, Mary; Ivanco, Dana; Medsger, Thomas A; Domsic, Robyn T

    2013-08-01

    Palpable tendon friction rubs (TFRs) in systemic sclerosis (SSc; scleroderma) have been associated with diffuse skin thickening, increased disability, and poor survival. Our objective was to quantify the prognostic implications of palpable TFRs on the development of disease complications and longer-term mortality in an incident cohort of early diffuse cutaneous SSc (dcSSc) patients. We identified early dcSSc patients (disease duration <2 years from the first SSc symptom) first evaluated at the University of Pittsburgh Scleroderma Center between 1980 and 2006 and found to have palpable TFRs. These patients were matched 1:1 with the next consecutive early dcSSc patient without TFRs as a control. All had ≥2 clinic visits and 5 years of followup from the first visit. A total of 287 early dcSSc patients with TFR were identified and matched to 287 controls. The median disease duration was 0.83 years in TFR patients and 1.04 years in controls. The median followup was 10.1 years in TFR patients and 7.9 years in controls. Over the course of their illness, patients with TFRs had a >2-fold risk of developing renal crisis and cardiac and gastrointestinal disease complications, even after adjustment for other known risk factors. Patients with TFRs had poorer 5- and 10-year survival rates. Patients with early dcSSc having ≥1 TFRs are at an increased risk of developing renal, cardiac, and gastrointestinal involvement before and after their first Scleroderma Center visit and have reduced survival. Patients presenting with TFRs should be carefully monitored for serious internal organ involvement. Copyright © 2013 by the American College of Rheumatology.

  10. The utility of hand transplantation in hand amputee patients.

    PubMed

    Alolabi, Noor; Chuback, Jennifer; Grad, Sharon; Thoma, Achilles

    2015-01-01

    To measure the desirable health outcome, termed utility, and the expected quality-adjusted life years (QALYs) gained with hand composite tissue allotransplantation (CTA) using hand amputee patients and the general public. Using the standard gamble (SG) and time trade-off (TTO) techniques, utilities were obtained from 30 general public participants and 12 amputee patients. The health utility and net QALYs gained or lost with transplantation were computed. A sensitivity analysis was conducted to account for the effects of lifelong immunosuppression on the life expectancy of transplant recipients. Higher scores represent greater utility. Hand amputation mean health utility as measured by the SG and TTO methods, respectively, was 0.72 and 0.80 for the general public and 0.69 and 0.70 for hand amputees. In comparison, hand CTA mean health utility was 0.74 and 0.82 for the general public and 0.83 and 0.86 for amputees. Hand CTA imparted an expected gain of 0.9 QALYs (SG and TTO) in the general public and 7.0 (TTO) and 7.8 (SG) QALYs in hand amputees. A loss of at least 1.7 QALYs was demonstrated when decreasing the life expectancy in the sensitivity analysis in the hand amputee group. Hand amputee patients did not show a preference toward hand CTA with its inherent risks. With this procedure being increasingly adopted worldwide, the benefits must be carefully weighed against the risks of lifelong immunosuppressive therapy. This study does not show clear benefit to advocate hand CTA. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  11. Reduction of illness absenteeism in elementary schools using an alcohol-free instant hand sanitizer.

    PubMed

    White, C G; Shinder, F S; Shinder, A L; Dyer, D L

    2001-10-01

    Hand washing is the most effective way to prevent the spread of communicable disease. The purpose of this double-blind, placebo-controlled study was to assess whether an alcohol-free, instant hand sanitizer containing surfactants, allantoin, and benzalkonium chloride could reduce illness absenteeism in a population of 769 elementary school children and serve as an effective alternative when regular soap and water hand washing was not readily available. Prior to the study, students were educated about proper hand washing technique, the importance of hand washing to prevent transmission of germs, and the relationship between germs and illnesses. Children in kindergarten through the 6th grade (ages 5-12) were assigned to the active or placebo hand-sanitizer product and instructed to use the product at scheduled times during the day and as needed after coughing or sneezing. Data on illness absenteeism were tracked. After 5 weeks, students using the active product were 33% less likely to have been absent because of illness when compared with the placebo group.

  12. Hand Matters: Left-Hand Gestures Enhance Metaphor Explanation

    ERIC Educational Resources Information Center

    Argyriou, Paraskevi; Mohr, Christine; Kita, Sotaro

    2017-01-01

    Research suggests that speech-accompanying gestures influence cognitive processes, but it is not clear whether the gestural benefit is specific to the gesturing hand. Two experiments tested the "(right/left) hand-specificity" hypothesis for self-oriented functions of gestures: gestures with a particular hand enhance cognitive processes…

  13. Comparison of the antimicrobial efficacy of povidone-iodine, povidone-iodine-ethanol and chlorhexidine gluconate-ethanol surgical scrubs.

    PubMed

    Nishimura, Chieko

    2006-01-01

    Scrubbing of the hands and forearms with a brush and antiseptic agents has been the standard for surgical practice. However, it has been increasingly recognized that brush scrubbing may provoke side effects and that an alcohol-based hand antiseptic used in conjunction with a scrub agent enhances the effectiveness. In this study, two types of alcohol-based agents were used after a povidone-iodine (PVP-I) scrub and compared for their effectiveness. The study was conducted as a crossover trial with 20 volunteers. After hand rubbing with PVP-I, either PVP-I-ethanol rubbing or chlorhexidine gluconate-ethanol (CHG-ethanol) rubbing was used for surgical hand cleansing. Samples were collected by the modified glove juice method to count bacteria on hands. In both groups, the bacterial count was significantly reduced after handwashing (p < 0.001), and the reduction was still significant after 2 h (p < 0.001 for PVP-I-ethanol and p < 0.002 for CHG-ethanol). The log(10) reduction factor (RF) in the PVP-I-ethanol group was significantly higher than that in the CHG-ethanol group immediately after handwashing (p < 0.001) but significantly lowered after 2 h (p < 0.01) to the level similar to that of CHG-ethanol. Although RF was lower in the CHG-ethanol group immediately after and 2 h after handwashing compared to the PVP-I-ethanol group, it did not decrease with time. Brushless surgical scrubbing with PVP-I-ethanol or CHG-ethanol in conjunction with PVP-I showed antiseptic effects immediately after and 2 h after handwashing. RF immediately after handwashing was significantly higher with PVP-I-ethanol compared to CHG-ethanol, but it was similar in both groups after 2 h. These results suggest that when used in combination with a PVP-I scrub, an alcohol-based hand antiseptic containing the same active agent (PVP-I in this study) has a powerful antiseptic effect; however, when it contains different antiseptic agents (i.e. CHG in this study), it should be selected carefully based on

  14. [Hand osteoarthritis].

    PubMed

    Šenolt, Ladislav

    Hand osteoarthritis (OA) is a common chronic disorder causing pain and limitation of mobility of affected joints. The prevalence of hand OA increases with age and more often affects females. Clinical signs obviously do not correlate with radiographic findings - symptomatic hand OA affects approximately 26 % of adult subjects, but radiographic changes can be found in up to two thirds of females and half of males older than 55 years.Disease course differ among individual patients. Hand OA is a heterogeneous disease. Nodal hand OA is the most common subtype affecting interphalangeal joints, thumb base OA affects first carpometacarpal joint. Erosive OA represents a specific subtype of hand OA, which is associated with joint inflammation, more pain, functional limitation and erosive findings on radiographs.Treatment of OA is limited. Analgesics and nonsteroidal anti-inflammatory drugs are the only agents reducing symptoms. New insights into the pathogenesis of disease should contribute to the development of novel effective treatment of hand OA.

  15. Hand hygiene in the intensive care unit.

    PubMed

    Tschudin-Sutter, Sarah; Pargger, Hans; Widmer, Andreas F

    2010-08-01

    Healthcare-associated infections affect 1.4 million patients at any time worldwide, as estimated by the World Health Organization. In intensive care units, the burden of healthcare-associated infections is greatly increased, causing additional morbidity and mortality. Multidrug-resistant pathogens are commonly involved in such infections and render effective treatment challenging. Proper hand hygiene is the single most important, simplest, and least expensive means of preventing healthcare-associated infections. In addition, it is equally important to stop transmission of multidrug-resistant pathogens. According to the Centers for Disease Control and Prevention and World Health Organization guidelines on hand hygiene in health care, alcohol-based handrub should be used as the preferred means for routine hand antisepsis. Alcohols have excellent in vitro activity against Gram-positive and Gram-negative bacteria, including multidrug-resistant pathogens, such as methicillin-resistant Staphylococcus aureus and vancomycin-resistant enterococci, Mycobacterium tuberculosis, a variety of fungi, and most viruses. Some pathogens, however, such as Clostridium difficile, Bacillus anthracis, and noroviruses, may require special hand hygiene measures. Failure to provide user friendliness of hand hygiene equipment and shortage of staff are predictors for noncompliance, especially in the intensive care unit setting. Therefore, practical approaches to promote hand hygiene in the intensive care unit include provision of a minimal number of handrub dispensers per bed, monitoring of compliance, and choice of the most attractive product. Lack of knowledge of guidelines for hand hygiene, lack of recognition of hand hygiene opportunities during patient care, and lack of awareness of the risk of cross-transmission of pathogens are barriers to good hand hygiene practices. Multidisciplinary programs to promote increased use of alcoholic handrub lead to an increased compliance of healthcare

  16. Stiff Hands

    MedlinePlus

    ... Stiff Hands Find a hand surgeon near you. Videos Figures Figure 1: Hand splint to help straighten ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  17. Hand Fractures

    MedlinePlus

    ... Hand Fractures Find a hand surgeon near you. Videos Hand Fractures Close Popup Figures Figure 1 - Examples ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  18. Bimanual Force Variability and Chronic Stroke: Asymmetrical Hand Control

    PubMed Central

    Kang, Nyeonju; Cauraugh, James H.

    2014-01-01

    The purpose of this study was to investigate force variability generated by both the paretic and non-paretic hands during bimanual force control. Nine chronic stroke individuals and nine age-matched individuals with no stroke history performed a force control task with both hands simultaneously. The task involved extending the wrist and fingers at 5%, 25%, and 50% of maximum voluntary contraction. Bimanual and unimanual force variability during bimanual force control was determined by calculating the coefficient of variation. Analyses revealed two main findings: (a) greater bimanual force variability in the stroke group than the control group and (b) increased force variability by the paretic hands during bimanual force control in comparison to the non-paretic hands at the 5% and 25% force production conditions. A primary conclusion is that post stroke bimanual force variability is asymmetrical between hands. PMID:25000185

  19. Natural Products as Anti-HIV Agents and Role in HIV-Associated Neurocognitive Disorders (HAND): A Brief Overview

    PubMed Central

    Kurapati, Kesava Rao V.; Atluri, Venkata S.; Samikkannu, Thangavel; Garcia, Gabriella; Nair, Madhavan P. N.

    2016-01-01

    As the threat of Human Immunodeficiency Virus (HIV)/Acquired Immunodeficiency Syndrome (AIDS) persists to rise, effective drug treatments are required to treat the infected people. Even though combination antiretroviral therapy (cART) provides stable viral suppression, it is not devoid of undesirable side effects, especially in persons undergoing long-term treatment. The present therapy finds its limitations in the emergence of multidrug resistance and accordingly finding new drugs and novel targets is the need of the hour to treat the infected persons and further to attack HIV reservoirs in the body like brain, lymph nodes to achieve the ultimate goal of complete eradication of HIV and AIDS. Natural products such as plant-originated compounds and plant extracts have enormous potential to become drug leads with anti-HIV and neuroprotective activity. Accordingly, many research groups are exploring the biodiversity of the plant kingdom to find new and better anti-HIV drugs with novel mechanisms of action and for HIV-associated neurocognitive disorders (HAND). The basic challenge that still persists is to develop viral replication-targeted therapy using novel anti-HIV compounds with new mode of action, accepted toxicity and less resistance profile. Against this backdrop, the World Health Organization (WHO) suggested the need to evaluate ethno-medicines for the management of HIV/AIDS. Consequently, there is need to evaluate traditional medicine, particularly medicinal plants and other natural products that may yield effective and affordable therapeutic agents. Although there are a good number of reports on traditional uses of plants to treat various diseases, knowledge of herbal remedies used to manage HIV/AIDS and HAND are scanty, vague and not well documented. In this review, plant substances showing a promising action that is anti-HIV and HAND will be explored along with what they interact. Since some plant substances are also known to modulate several cellular

  20. Effect of hand sanitizer use on elementary school absenteeism.

    PubMed

    Hammond, B; Ali, Y; Fendler, E; Dolan, M; Donovan, S

    2000-10-01

    Several studies have indicated a connection between handwashing and illness-related absenteeism in school settings. The difficulty of ensuring consistent and effective handwashing among student populations has also been noted. The purpose of this study was to assess the effectiveness of the use of an alcohol gel hand sanitizer in the classroom to help decrease the illness-related absentee rate for elementary school students. This study involved 5 individual school districts, 16 individual schools, and more than 6000 students in Delaware, Ohio, Tennessee, and California. Individual schools in each district were paired into product and control groups. In the product group schools, an alcohol gel hand sanitizer was used by the students and staff when entering and leaving the classroom. Absenteeism due to infection was recorded, and the data were statistically analyzed. The overall reduction in absenteeism due to infection in the schools included in this study was 19.8% for schools that used an alcohol gel hand sanitizer compared with the control schools (P <.05). Data from the school system with the largest teacher population (n = 246) showed that teacher absenteeism decreased 10.1% (trend) in the schools where sanitizer was used. Elementary school absenteeism due to infection is significantly reduced when an alcohol gel hand sanitizer is used in the classroom as part of a hand hygiene program.

  1. Health care worker hand hygiene in the pediatric special care unit at Mulago National Referral Hospital in Uganda: a best practice implementation project.

    PubMed

    Muhumuza, Christine; Gomersall, Judith Streak; Fredrick, Makumbi E; Atuyambe, Lynn; Okiira, Christopher; Mukose, Aggrey; Ssempebwa, John

    2015-03-01

    The hands of a health care worker are a common vehicle of pathogen transmission in hospital settings. Health care worker hand hygiene is therefore critical for patients' well being. Whilst failure of health care workers to comply with the best hand hygiene practice is a problem in all health care settings, issues of lack of access to adequate cleaning equipment and in some cases even running water make practicing good hand hygiene particularly difficult in low-resource developing country settings. This study reports an audit and feedback project that focused on the hand hygiene of the health care worker in the pediatric special care unit of the Mulago National Referral Hospital, which is a low-resource setting in Uganda. To improve hand hygiene among health care workers in the pediatric special care unit and thereby contribute to reducing transmission of health care worker-associated pathogens. The Joanna Briggs Institute three-phase Practical Application of Clinical Evidence System audit and feedback tool for promoting evidence utilization and change in health care was used. In phase one of the project, stakeholders were engaged and seven evidence-based audit criteria were developed. A baseline audit was then conducted. In phase two, barriers underpinning areas of noncompliance found in the baseline audit were identified and three strategies - education, reminders and provision of hand cleaning equipment - were implemented to overcome them. In phase three, a follow-up audit was conducted. Compliance with best practice hygiene was found to be poor in the baseline audit for all but one of the audit criteria. Following the implementation of the strategies, hand hygiene improved. The compliance rate increased substantially across all criteria. Staff education achieved 100%, whilst criterion 4 increased to 70%. However, use of alcohol-based hand-rub for hand hygiene only improved to 66%, and for six of the seven audit criteria, compliance remained below 74%. The

  2. Self-reported reasons for hand hygiene in 3 groups of health care workers.

    PubMed

    McLaughlin, Anne Collins; Walsh, Fran

    2012-09-01

    The hands of health care workers continue to be the main vector for nosocomial infection in hospitals. The purpose of the current research was to capture the health beliefs and self-reported behaviors of US health care workers to better understand why workers avoid hand hygiene and what prompts them to wash. An online survey of health care workers assessed their reasons for washing their hands, reasons for not washing, and what cues prompted the decision to wash or not wash in a variety of locations. The findings were that hand hygiene could be cued by an external situation but tended to be motivated internally. Hand hygiene was avoided because of situational barriers. The reasons for performing hand hygiene can be situated in the internally motivated Theory of Planned Behavior; however, the reasons for not performing hand hygiene tend to be situational and affected by the environment. The results may be used to design programs, products, and systems that promote appropriate hand hygiene practices. Principles for design of these programs and products are provided. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  3. Can hand laterality be identified through lithic technology?

    PubMed

    Bargalló, Amèlia; Mosquera, Marina

    2014-01-01

    In this paper we present a new method for inferring handedness from lithic evidence. The study was conducted by means of an experimental programme in stone-knapping, after which the resulting lithic products (tools) were analysed. These lithic tools were produced by 15 inexpert knappers (8 right-handed and 7 left-handed), because we were not able to find a statistically significant number of left-handed expert knappers. We considered inexpert knappers to include individuals who had never struck two pebbles together, as well as individuals who were quite familiar with prehistoric tools and had had some degree of practice. The Mann-Whitney U test proved that all of them produced flakes with the same technical features, so within this sample expertise was not a factor that affected the presence or absence of the technical features analysed to determine hand laterality. The results of the experiment indicate that no single variable can be used to determine the laterality of the knapper, but rather the evidence of handedness lies in the combination of several variables. Furthermore, not all the flakes display the entire set of significant features. Therefore this study concludes that it is not possible to determine the handedness of a knapper through a single variable present on his or her flakes, but it may be possible to determine laterality by examining a combination of technical variables on a number of his or her pieces. Archaeologically, only well-preserved knapping events with numerous refitting products can be assigned to a left- or a right-handed knapper.

  4. Hand Washing

    MedlinePlus

    ... study, only 58% of female and 48% of male middle- and high-school students washed their hands after using the bathroom. Yuck! How to Wash Your Hands Correctly There's a right way to wash your hands. Follow these simple ...

  5. Functional magnetic resonance imaging exploration of combined hand and speech movements in Parkinson's disease.

    PubMed

    Pinto, Serge; Mancini, Laura; Jahanshahi, Marjan; Thornton, John S; Tripoliti, Elina; Yousry, Tarek A; Limousin, Patricia

    2011-10-01

    Among the repertoire of motor functions, although hand movement and speech production tasks have been investigated widely by functional neuroimaging, paradigms combining both movements have been studied less so. Such paradigms are of particular interest in Parkinson's disease, in which patients have specific difficulties performing two movements simultaneously. In 9 unmedicated patients with Parkinson's disease and 15 healthy control subjects, externally cued tasks (i.e., hand movement, speech production, and combined hand movement and speech production) were performed twice in a random order and functional magnetic resonance imaging detected cerebral activations, compared to the rest. F-statistics tested within-group (significant activations at P values < 0.05, familywise error corrected), between-group, and between-task comparisons (regional activations significant at P values < 0.001, uncorrected, with cluster size > 10 voxels). For control subjects, the combined task activations comprised the sum of those obtained during hand movement and speech production performed separately, reflecting the neural correlates of performing movements sharing similar programming modalities. In patients with Parkinson's disease, only activations underlying hand movement were observed during the combined task. We interpreted this phenomenon as patients' potential inability to recruit facilitatory activations while performing two movements simultaneously. This lost capacity could be related to a functional prioritization of one movement (i.e., hand movement), in comparison with the other (i.e., speech production). Our observation could also reflect the inability of patients with Parkinson's disease to intrinsically engage the motor coordination necessary to perform a combined task. Copyright © 2011 Movement Disorder Society.

  6. When Computer Writers Compose by Hand.

    ERIC Educational Resources Information Center

    Collier, Richard; Werier, Clifford

    1995-01-01

    Reviews videotapes of three professional writers composing several essays from start to finish, both by hand and by computer. Discusses similarities and differences among the completed essays. Finds that writing appears to be governed by deep cognitive models that are little influenced by the mode of text production or by the writer's preference…

  7. Inspections of hand washing supplies and hand sanitizer in public schools.

    PubMed

    Ramos, Mary M; Blea, Mary; Trujillo, Rebecca; Greenberg, Cynthia

    2010-10-01

    Hand washing and hand antisepsis are proven infection control measures in the school setting, yet barriers such as lack of soap, paper towels, and hand sanitizer can hinder compliance. This pilot study measured the prevalence of hand cleaning supplies in public schools. Ten school districts (93 schools) participated in school nurse inspections. In November 2008, 90 schools (97%) reported their inspection results. Among 697 total bathrooms, 88.8% had soap and 91.7% had paper towels or hand dryers. Hand sanitizer was reported in 1.2% of bathrooms and 15.2% of cafeterias. No difference was observed between boys' and girls' bathrooms, or primary and secondary schools, in the prevalence of soap or paper towels/hand dryers. Hand washing supplies were generally available in public school bathrooms. Alcohol-based hand sanitizer in school bathrooms was reported occasionally and should be discouraged. Hand sanitizer in a supervised setting, the school cafeteria, was not often reported and should be promoted.

  8. Moisturizing alcohol hand gels for surgical hand preparation.

    PubMed

    Jones, R D; Jampani, H; Mulberry, G; Rizer, R L

    2000-03-01

    With the use of novel formulary technology, unique moisturizing hand gels have been developed that offer significant advantages in perioperative and other health care settings. These advantages include the time-saving capabilities of a waterless formulation, the persistence and effectiveness of a surgical scrub, and the moisturization and protective properties of a lotion. Extensive laboratory and clinical studies, involving in vivo antimicrobial activity against resident and transient flora, skin moisturization on normal and dry skin, and compatibility with latex gloves, have supported these advantages. Nondrying alcohol hand gels can be used for antiseptic hand washing, hand scrubs between procedures (i.e., reentry scrubs), brushless surgical scrubs, moisturizers, and glove-donning aids.

  9. Methods for evaluating changes in skin condition due to the effects of antimicrobial hand cleansers: two studies comparing a new waterless chlorhexidine gluconate/ethanol-emollient antiseptic preparation with a conventional water-applied product.

    PubMed

    Grove, G L; Zerweck, C R; Heilman, J M; Pyrek, J D

    2001-12-01

    Hand-cleansing products that are milder to the skin of health care personnel are being developed, but the available methodologies to appropriately evaluate these products and quantify differences are not generally being applied in well-controlled studies. Two randomized, blinded, bilateral comparison studies evaluated skin condition during use of 2 antiseptic hand preparation products: a new 1% chlorhexidine gluconate (CHG)/61% wt/wt ethanol antiseptic hand preparation in a unique emollient system for waterless/brushless application and a conventional 4% CHG antimicrobial product that is applied with water and a scrub brush. Trained technicians applied treatments 6 times (for a surgical scrub study) or 24 times (for a personnel handwash study) daily to the hands of healthy volunteers during 5 days of controlled washing. An expert grader evaluated skin for dryness, erythema, and roughness. Subjects completed a self-assessment questionnaire on skin condition. Transepidermal water loss was measured by an evaporimeter, and the skin surface hydration level was measured by an electrical conductance meter. Fifty-eight subjects were enrolled in the 2 studies and received both treatments. In general, skin treated with the waterless CHG/ethanol product scored significantly (P <.004) better on evaluations of visual dryness and erythema and showed greater improvement in the level of hydration (P <.003). In the health care personnel handwash study, transepidermal water loss was less than that for skin treated with the conventional CHG product (P <.002). Subject assessments showed similar results (total score, P <.007). All 3 approaches of expert grader evaluation, subject assessment, and instrumentation were in concordance, demonstrating that the waterless CHG/ethanol product was gentler to skin than the conventional CHG product.

  10. Design of rehabilitation robot hand for fingers CPM training

    NASA Astrophysics Data System (ADS)

    Zhou, Hongfu; Chan, T. W.; Tong, K. Y.; Kwong, K. K.; Yao, Xifan

    2008-10-01

    This paper presents a low-cost prototype for rehabilitation robot aide patient do hands CPM (continuous passive motion) training. The design of the prototype is based on the principle of Rutgers Master II glove, but it is better in performance for more improvement made. In the design, it uses linear motors to replace pneumatic actuators to make the product more portable and mobile. It increases finger training range to 180 degree for the full range training of hand finger holding and extension. Also the prototype can not only be wearing on palm and fore arm do training for face to face with finger move together, but also be put in the opposite hand glove wear direction for hand rehabilitation training. During the research, Solidworks is used as the tool for mechanical design and movement simulation. It proved through experiment that the prototype made in the research is appropriate for hand do CPM training.

  11. Effect of tetramethylsilane flow on the deposition and tribological behaviors of silicon doped diamond-like carbon rubbed against poly(oxymethylene)

    NASA Astrophysics Data System (ADS)

    Deng, Xingrui; Lim, Yankuang; Kousaka, Hiroyuki; Tokoroyama, Takayuki; Umehara, Noritsugu

    2014-11-01

    In this study, silicon doped diamond-like carbon (Si-DLC) was deposited on stainless steel (JIS SUS304) by using surface wave-excited plasma (SWP). The effects of tetramethylsilane (TMS) flow on the composition, topography, mechanical properties and tribological behavior were investigated. Pin-on-disc tribo-meter was used to investigate the tribological behavior of the Si-DLC coating rubbed against poly(oxymethylene) (POM). The results show that the deposition rate, roughness of Si-DLC increased and the hardness of Si-DLC decreased with the increase of TMS flow rate from 2 to 4 sccm; the roughness increase therein led to the increase of ploughing term of friction. The increase of adhesion term was also seen with the increase of TMS flow rate, being attributed to the decrease of hydrogen concentration in the coating. It was considered that more POM transferred onto the Si-DLC deposited at higher TMS flow rate due to larger heat generation by friction.

  12. Hand preference for sending mobile-phone text messages: associations with sex, writing hand, and throwing hand.

    PubMed

    Lambert, Anthony; Hallett, Charlene

    2009-07-01

    Hand preference for sending mobile-phone text messages ("texting") and its relationship with hand preference for other activities were investigated in a questionnaire study with 886 participants. Overall rates of both sinistrality and dextrality were reduced for texting, in comparison with other activities, due to the substantial number of individuals who use both hands simultaneously when performing this activity. Because they both involve verbal expression, it was hypothesised that the association between hand preferences for texting and writing might be stronger than the association between either of these tasks and more spatial activities, such as throwing. This prediction was not confirmed, either in the sample as a whole or in a sub-group of individuals who reported writing and throwing with opposite hands. Females were less likely than males to use their left hand when sending text messages. Implications of these findings are discussed, in relation to theoretical views of handedness and in relation to practical aspects of mobile-phone design.

  13. Non-thermal production of minimal dark matter via right-handed neutrino decay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aoki, Mayumi; Toma, Takashi; Vicente, Avelino

    2015-09-29

    Minimal Dark Matter (MDM) stands as one of the simplest dark matter scenarios. In MDM models, annihilation and co-annihilation processes among the members of the MDM multiplet are usually very efficient, pushing the dark matter mass above O(10) TeV in order to reproduce the observed dark matter relic density. Motivated by this little drawback, in this paper we consider an extension of the MDM scenario by three right-handed neutrinos. Two specific choices for the MDM multiplet are studied: a fermionic SU(2){sub L} quintuplet and a scalar SU(2){sub L} septuplet. The lightest right-handed neutrino, with tiny Yukawa couplings, never reaches thermalmore » equilibrium in the early universe and is produced by freeze-in. This creates a link between dark matter and neutrino physics: dark matter can be non-thermally produced by the decay of the lightest right-handed neutrino after freeze-out, allowing to lower significantly the dark matter mass. We discuss the phenomenology of the non-thermally produced MDM and, taking into account significant Sommerfeld corrections, we find that the dark matter mass must have some specific values in order not to be in conflict with the current bounds from gamma-ray observations.« less

  14. Non-thermal production of minimal dark matter via right-handed neutrino decay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aoki, Mayumi; Toma, Takashi; Vicente, Avelino, E-mail: mayumi@hep.s.kanazawa-u.ac.jp, E-mail: takashi.toma@th.u-psud.fr, E-mail: Avelino.Vicente@ulg.ac.be

    2015-09-01

    Minimal Dark Matter (MDM) stands as one of the simplest dark matter scenarios. In MDM models, annihilation and co-annihilation processes among the members of the MDM multiplet are usually very efficient, pushing the dark matter mass above O(10) TeV in order to reproduce the observed dark matter relic density. Motivated by this little drawback, in this paper we consider an extension of the MDM scenario by three right-handed neutrinos. Two specific choices for the MDM multiplet are studied: a fermionic SU(2){sub L} quintuplet and a scalar SU(2){sub L} septuplet. The lightest right-handed neutrino, with tiny Yukawa couplings, never reaches thermalmore » equilibrium in the early universe and is produced by freeze-in. This creates a link between dark matter and neutrino physics: dark matter can be non-thermally produced by the decay of the lightest right-handed neutrino after freeze-out, allowing to lower significantly the dark matter mass. We discuss the phenomenology of the non-thermally produced MDM and, taking into account significant Sommerfeld corrections, we find that the dark matter mass must have some specific values in order not to be in conflict with the current bounds from gamma-ray observations.« less

  15. The Weak Link HP-41C hand-held calculator program

    Treesearch

    Ross A. Phillips; Penn A. Peters; Gary D. Falk

    1982-01-01

    The Weak Link hand-held calculator program (HP-41C) quickly analyzes a system for logging production and costs. The production equations model conventional chain saw, skidder, loader, and tandemaxle truck operations in eastern mountain areas. Production of each function of the logging system may be determined so that the system may be balanced for minimum cost. The...

  16. Hand biometric recognition based on fused hand geometry and vascular patterns.

    PubMed

    Park, GiTae; Kim, Soowon

    2013-02-28

    A hand biometric authentication method based on measurements of the user's hand geometry and vascular pattern is proposed. To acquire the hand geometry, the thickness of the side view of the hand, the K-curvature with a hand-shaped chain code, the lengths and angles of the finger valleys, and the lengths and profiles of the fingers were used, and for the vascular pattern, the direction-based vascular-pattern extraction method was used, and thus, a new multimodal biometric approach is proposed. The proposed multimodal biometric system uses only one image to extract the feature points. This system can be configured for low-cost devices. Our multimodal biometric-approach hand-geometry (the side view of the hand and the back of hand) and vascular-pattern recognition method performs at the score level. The results of our study showed that the equal error rate of the proposed system was 0.06%.

  17. Vicariously touching products through observing others' hand actions increases purchasing intention, and the effect of visual perspective in this process: An fMRI study.

    PubMed

    Liu, Yi; Zang, Xuelian; Chen, Lihan; Assumpção, Leonardo; Li, Hong

    2018-01-01

    The growth of online shopping increases consumers' dependence on vicarious sensory experiences, such as observing others touching products in commercials. However, empirical evidence on whether observing others' sensory experiences increases purchasing intention is still scarce. In the present study, participants observed others interacting with products in the first- or third-person perspective in video clips, and their neural responses were measured with functional magnetic resonance imaging (fMRI). We investigated (1) whether and how vicariously touching certain products affected purchasing intention, and the neural correlates of this process; and (2) how visual perspective interacts with vicarious tactility. Vicarious tactile experiences were manipulated by hand actions touching or not touching the products, while the visual perspective was manipulated by showing the hand actions either in first- or third-person perspective. During the fMRI scanning, participants watched the video clips and rated their purchasing intention for each product. The results showed that, observing others touching (vs. not touching) the products increased purchasing intention, with vicarious neural responses found in mirror neuron systems (MNS) and lateral occipital complex (LOC). Moreover, the stronger neural activities in MNS was associated with higher purchasing intention. The effects of visual perspectives were found in left superior parietal lobule (SPL), while the interaction of tactility and visual perspective was shown in precuneus and precuneus-LOC connectivity. The present study provides the first evidence that vicariously touching a given product increased purchasing intention and the neural activities in bilateral MNS, LOC, left SPL and precuneus are involved in this process. Hum Brain Mapp 39:332-343, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  18. The Rubber Hand Illusion: Feeling of Ownership and Proprioceptive Drift Do Not Go Hand in Hand

    PubMed Central

    Rohde, Marieke; Di Luca, Massimiliano; Ernst, Marc O.

    2011-01-01

    In the Rubber Hand Illusion, the feeling of ownership of a rubber hand displaced from a participant's real occluded hand is evoked by synchronously stroking both hands with paintbrushes. A change of perceived finger location towards the rubber hand (proprioceptive drift) has been reported to correlate with this illusion. To measure the time course of proprioceptive drift during the Rubber Hand Illusion, we regularly interrupted stroking (performed by robot arms) to measure perceived finger location. Measurements were made by projecting a probe dot into the field of view (using a semi-transparent mirror) and asking participants if the dot is to the left or to the right of their invisible hand (Experiment 1) or to adjust the position of the dot to that of their invisible hand (Experiment 2). We varied both the measurement frequency (every 10 s, 40 s, 120 s) and the mode of stroking (synchronous, asynchronous, just vision). Surprisingly, with frequent measurements, proprioceptive drift occurs not only in the synchronous stroking condition but also in the two control conditions (asynchronous stroking, just vision). Proprioceptive drift in the synchronous stroking condition is never higher than in the just vision condition. Only continuous exposure to asynchronous stroking prevents proprioceptive drift and thus replicates the differences in drift reported in the literature. By contrast, complementary subjective ratings (questionnaire) show that the feeling of ownership requires synchronous stroking and is not present in the asynchronous stroking condition. Thus, subjective ratings and drift are dissociated. We conclude that different mechanisms of multisensory integration are responsible for proprioceptive drift and the feeling of ownership. Proprioceptive drift relies on visuoproprioceptive integration alone, a process that is inhibited by asynchronous stroking, the most common control condition in Rubber Hand Illusion experiments. This dissociation implies that

  19. New discovery of coral rubbings in the north-western Gulf of Kachchh, Gujarat, Western India — GIS based evaluation

    NASA Astrophysics Data System (ADS)

    Sesh Serebiah, J.; Rajkumar, M.; Sun, Jun; Venmathi Maran, B. A.; Saravanakumar, A.; Thivakaran, G. A.

    2011-06-01

    The Gulf of Kachchh in western India, with its arid climate, large semi-diurnal tidal amplitudes, negative water balance and near-pristine water quality, is being extensively developed as oil importing bases for economic reasons in connection with its proximity to the oil exporting countries of the Middle East. Besides, new coral rubbings were sighted in Jakhau, north-western Gulf of Kachchh. Dredging in Mandvi of the north Gulf covering 3.5 km2 revealed a similar assortment of live corals with their associated flora and fauna. These pioneering observations demonstrate that there exist live corals of young polyps-colony of Favia sp. belonging to the family Faviidae in the north-western Gulf of Kachchh. The environmental parameters there were carefully recorded as: surface water temperature (°C) varying from 29 to 31.8, salinity (ppt), pH, dissolved oxygen (mgL-1) and total suspended solids (mgL-1) in the ranges of 37-43.5, 7.7-8.45, 5.4-6.8 and 11-31, respectively.

  20. Fitting a hand-glove prosthesis to enhance the reconstructed mutilated hand.

    PubMed

    Leow, M E; Kour, A K; Pereira, B P; Pho, R W

    1998-03-01

    Microsurgical reconstruction of the severely mutilated hand aimed at improving prehensile functions often does not address the esthetic aspects of the hand. The poor appearance of the reconstructed hand affects its active display and use. A hand-glove prosthesis may be prescribed in this instance to enhance the overall form and function of the mutilated hand. We reviewed 16 cases of mutilating hand injuries in which surgical reconstructions were performed and the patients were subsequently fitted with a hand-glove prosthesis to augment the outcome. An improved appearance was achieved in all patients fitted with the prosthesis. The patients' sense of confidence was also enhanced, which in turn promoted the active and open use of the reconstructed hands. While prescribed primarily to improve the appearance of the reconstructed hands, these prostheses were documented to enhance the physical hand functions in 11 cases by increasing the span of the hand and providing an opposable post and a palmar base for holding and for anchorage. The prosthesis enhanced assistive functions of the reconstructed hands and freed the contralateral normal hand for use in bimanual activities, such as holding a wallet and taking out money, supporting a note pad for writing, and holding a plate at buffet receptions. At the 18-month follow-up visit, 13 (87%) of the patients continued to use their prosthesis. Wear and tear were problems associated with the frequent use of the prosthesis. The expected life span of the prosthesis with daily use ranged from 2 to 3 years. All the patients acknowledged that the prosthesis played a role in their rehabilitation and that it helped them to overcome the initial psychological trauma and to come to terms with their physical loss.

  1. Hand movements with a phase structure and gestures that depict action stem from a left hemispheric system of conceptualization.

    PubMed

    Helmich, I; Lausberg, H

    2014-10-01

    The present study addresses the previously discussed controversy on the contribution of the right and left cerebral hemispheres to the production and conceptualization of spontaneous hand movements and gestures. Although it has been shown that each hemisphere contains the ability to produce hand movements, results of left hemispherically lateralized motor functions challenge the view of a contralateral hand movement production system. To examine hemispheric specialization in hand movement and gesture production, ten right-handed participants were tachistoscopically presented pictures of everyday life actions. The participants were asked to demonstrate with their hands, but without speaking what they had seen on the drawing. Two independent blind raters evaluated the videotaped hand movements and gestures employing the Neuropsychological Gesture Coding System. The results showed that the overall frequency of right- and left-hand movements is equal independent of stimulus lateralization. When hand movements were analyzed considering their Structure, the presentation of the action stimuli to the left hemisphere resulted in more hand movements with a phase structure than the presentation to the right hemisphere. Furthermore, the presentation to the left hemisphere resulted in more right and left-hand movements with a phase structure, whereas the presentation to the right hemisphere only increased contralateral left-hand movements with a phase structure as compared to hand movements without a phase structure. Gestures that depict action were primarily displayed in response to stimuli presented in the right visual field than in the left one. The present study shows that both hemispheres possess the faculty to produce hand movements in response to action stimuli. However, the left hemisphere dominates the production of hand movements with a phase structure and gestures that depict action. We therefore conclude that hand movements with a phase structure and gestures that

  2. Hand Biometric Recognition Based on Fused Hand Geometry and Vascular Patterns

    PubMed Central

    Park, GiTae; Kim, Soowon

    2013-01-01

    A hand biometric authentication method based on measurements of the user's hand geometry and vascular pattern is proposed. To acquire the hand geometry, the thickness of the side view of the hand, the K-curvature with a hand-shaped chain code, the lengths and angles of the finger valleys, and the lengths and profiles of the fingers were used, and for the vascular pattern, the direction-based vascular-pattern extraction method was used, and thus, a new multimodal biometric approach is proposed. The proposed multimodal biometric system uses only one image to extract the feature points. This system can be configured for low-cost devices. Our multimodal biometric-approach hand-geometry (the side view of the hand and the back of hand) and vascular-pattern recognition method performs at the score level. The results of our study showed that the equal error rate of the proposed system was 0.06%. PMID:23449119

  3. The association between hemispheric specialization for language production and for spatial attention depends on left-hand preference strength.

    PubMed

    Zago, Laure; Petit, Laurent; Mellet, Emmanuel; Jobard, Gaël; Crivello, Fabrice; Joliot, Marc; Mazoyer, Bernard; Tzourio-Mazoyer, Nathalie

    2016-12-01

    Cerebral lateralization for language production and spatial attention and their relationships with manual preference strength (MPS) were assessed in a sample of 293 healthy volunteers, including 151 left-handers, using fMRI during covert sentence production (PROD) and line bisection judgment (LBJ) tasks, as compared to high- and low-level reference tasks. At the group level, we found the expected complementary hemispheric specialization (HS) with leftward asymmetries for PROD within frontal and temporal regions and rightward asymmetries for LBJ within frontal and posterior occipito-parieto-temporal regions. Individual hemispheric (HLI) and regional (frontal and occipital) lateralization indices (LI) were then calculated on the activation maps for PROD and LBJ. We found a correlation between the degree of rightward cerebral asymmetry and the leftward behavioral attentional bias recorded during LBJ task. This correlation was found when LBJ-LI was computed over the hemispheres, in the frontal lobes, but not in the occipital lobes. We then investigated whether language production and spatial attention cerebral lateralization relate to each other, and whether manual preference was a variable that impacted the complementary HS of these functions. No correlation was found between spatial and language LIs in the majority of our sample of participants, including right-handers with a strong right-hand preference (sRH, n=97) and mixed-handers (MH, n=97), indicating that these functions lateralized independently. By contrast, in the group of left-handers with a strong left-hand preference (sLH, n= 99), a negative correlation was found between language and spatial lateralization. This negative correlation was found when LBJ-LI and PROD-LI were computed over the hemispheres, in the frontal lobes and between the occipital lobes for LBJ and the frontal lobes for PROD. These findings underline the importance to include sLH in the study sample to reveal the underlying mechanisms of

  4. 42 CFR 403.744 - Condition of participation: Life safety from fire.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... written fire control plans that contain provisions for prompt reporting of fires; extinguishing fires...) The RNHCI must maintain written evidence of regular inspection and approval by State or local fire... contrary, the RNHCI may place alcohol-based hand rub dispensers in its facility if— (i) Use of alcohol...

  5. Interventions to improve patient hand hygiene: a systematic review.

    PubMed

    Srigley, J A; Furness, C D; Gardam, M

    2016-09-01

    Nosocomial pathogens may be acquired by patients via their own unclean hands, but there has been relatively little emphasis on patient hand hygiene as a tool for preventing healthcare-associated infections (HCAIs). The aim of this systematic review was to determine the efficacy of patient hand hygiene interventions in reducing HCAIs and improving patient hand hygiene rates compared to usual care. Electronic databases and grey literature were searched to August 2014. Experimental and quasi-experimental studies were included if they evaluated a patient hand hygiene intervention conducted in an acute or chronic healthcare facility and included HCAI incidence and/or patient hand hygiene rates as an outcome. All steps were performed independently by two investigators. Ten studies were included, most of which were uncontrolled before-after studies (N=8). The majority of interventions (N=7) were multi-modal, with components similar to healthcare worker hand hygiene programmes, including education, reminders, audit and feedback, and provision of hand hygiene products. Six studies reported HCAI outcomes and four studies assessed patient hand hygiene rates; all demonstrated improvements but were at moderate to high risk of bias. In conclusion, interventions to improve patient hand hygiene may reduce the incidence of HCAIs and improve hand hygiene rates, but the quality of evidence is low. Future studies should use stronger designs and be more selective in their choice of outcomes. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  6. Inspections of Hand Washing Supplies and Hand Sanitizer in Public Schools

    ERIC Educational Resources Information Center

    Ramos, Mary M.; Blea, Mary; Trujillo, Rebecca; Greenberg, Cynthia

    2010-01-01

    Hand washing and hand antisepsis are proven infection control measures in the school setting, yet barriers such as lack of soap, paper towels, and hand sanitizer can hinder compliance. This pilot study measured the prevalence of hand cleaning supplies in public schools. Ten school districts (93 schools) participated in school nurse inspections. In…

  7. Effect of hand sanitizer location on hand hygiene compliance.

    PubMed

    Cure, Laila; Van Enk, Richard

    2015-09-01

    Hand hygiene is the most important intervention to prevent infection in hospitals. Health care workers should clean their hands at least before and after contact with patients. Hand sanitizer dispensers are important to support hand hygiene because they can be made available throughout hospital units. The aim of this study was to determine whether the usability of sanitizer dispensers correlates with compliance of staff in using the sanitizer in a hospital. This study took place in a Midwest, 404-bed, private, nonprofit community hospital with 15 inpatient care units in addition to several ambulatory units. The usability and standardization of sanitizers in 12 participating inpatient units were evaluated. The hospital measured compliance of staff with hand hygiene as part of their quality improvement program. Data from 2010-2012 were analyzed to measure the relationship between compliance and usability using mixed-effects logistic regression models. The total usability score (P = .0046), visibility (P = .003), and accessibility of the sanitizer on entrance to the patient room (P = .00055) were statistically associated with higher observed compliance rates. Standardization alone showed no significant impact on observed compliance (P = .37). Hand hygiene compliance can be influenced by visibility and accessibility of dispensers. The sanitizer location should be part of multifaceted interventions to improve hand hygiene. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  8. Occupational risk factors for hand dermatitis among professional cleaners in Spain.

    PubMed

    Mirabelli, Maria C; Vizcaya, David; Martí Margarit, Anna; Antó, Josep Maria; Arjona, Lourdes; Barreiro, Esther; Orriols, Ramon; Gimenez-Arnau, Ana; Zock, Jan-Paul

    2012-04-01

    Dermatitis is an important health outcome for workers whose jobs put them in contact with irritants or sensitizing agents. We conducted an analysis of data from the Epidemiological Study on the Risk of Asthma in Cleaning Workers 2 (EPIASLI2) to assess worksites and cleaning products as risk factors for hand dermatitis among professional cleaning workers. We distributed 4993 questionnaires to employees of 37 cleaning companies, and used data from 818 (16%) respondents who provided information about skin symptoms and cleaning-related exposures. We assessed associations between the frequencies of worksite and cleaning product exposures and a symptom-based definition of hand dermatitis among current cleaning workers (n = 693) and a comparison population (n = 125). Hand dermatitis was reported by 28% of current cleaning workers, versus 18% of the comparison population, and was associated with cleaning outdoor areas and schools, and the use of hydrochloric acid [prevalence ratio (PR) 1.92, 95% confidence interval (CI) 1.22-3.02] and dust mop products (PR 1.75, 95% CI 1.11-2.75). Professional cleaning workers may not be sufficiently protected from cutaneous disease at work. Future research should further investigate the roles of multiple product exposures and personal protective equipment. © 2012 John Wiley & Sons A/S.

  9. Occupational risk factors for hand dermatitis among professional cleaners in Spain

    PubMed Central

    Mirabelli, Maria C.; Vizcaya, David; Margarit, Anna Martí; Antó, Josep Maria; Arjona, Lourdes; Barreiro, Esther; Orriols, Ramon; Gimenez-Arnau, Ana; Zock, Jan-Paul

    2012-01-01

    Summary Background Dermatitis is an important health outcome for workers whose jobs put them in contact with irritants or sensitizing agents. Objectives We conducted analysis of data from the Epidemiological Study on the Risk of Asthma in Cleaning Workers 2 (EPIASLI2) study to assess worksites and cleaning products as risk factors for hand dermatitis among professional cleaning workers. Materials/Methods We distributed 4 993 questionnaires to employees of 37 cleaning companies and used data from 818 (16%) respondents who provided information about skin symptoms and cleaning-related exposures. We assessed associations between the frequencies of worksite and cleaning product exposures and a symptom-based definition of hand dermatitis among current cleaning workers (n=693) and a comparison population (n=125). Results Hand dermatitis was reported by 28% of current cleaning workers, versus 18% of the comparison population, and was associated with cleaning outdoor areas and schools, and the use of hydrochloric acid (prevalence ratio [PR]: 1.92, 95% confidence interval [CI]: 1.22, 3.02) and dust mop products (PR: 1.75, 95% CI: 1.11, 2.75). Conclusions Professional cleaning workers may not be sufficiently protected from cutaneous disease at work. Future research should further investigate the roles of multiple product exposures and personal protective equipment. PMID:22268785

  10. Hand hygiene compliance rates in the United States--a one-year multicenter collaboration using product/volume usage measurement and feedback.

    PubMed

    McGuckin, Maryanne; Waterman, Richard; Govednik, John

    2009-01-01

    Hand hygiene (HH) is the single most important factor in the prevention of health care-acquired infections. The 3 most frequently reported methods of measuring HH compliance are: (1) direct observation, (2) self-reporting by health care workers (HCWs), and (3) indirect calculation based on HH product usage. This article presents the results of a 12-month multicenter collaboration assessing HH compliance rates at US health care facilities by measuring product usage and providing feedback about HH compliance. Our results show that HH compliance at baseline was 26% for intensive care units (ICUs) and 36% for non-ICUs. After 12 months of measuring product usage and providing feedback, compliance increased to 37% for ICUs and 51% for non-ICUs. (ICU, P = .0119; non-ICU, P < .001). HH compliance in the United States can increase when monitoring is combined with feedback. However, HH still occurs at or below 50% compli- ance for both ICUs and non-ICUs.

  11. HandTutor™ enhanced hand rehabilitation after stroke--a pilot study.

    PubMed

    Carmeli, Eli; Peleg, Sara; Bartur, Gadi; Elbo, Enbal; Vatine, Jean-Jacques

    2011-12-01

    This study assessed the potential therapeutic benefi t of using HandTutor™ in combination with traditional rehabilitation in a post-stroke sub-acute population. The study compares an experimental group receiving traditional therapy combined with HandTutorTM treatment, against a control group receiving only traditional therapy. An assessor-blinded, randomized controlled pilot trial, was conducted in the Reuth rehabilitation unit in Israel. Thirty-one stroke patients in the sub-acute phase, were randomly assigned to one of the two groups (experimental or control) in sets of three. The experimental group (n = 16) underwent a hand rehabilitation programme using the HandTutorTM combined with traditional therapy. The control group (n = 15) received only traditional therapy. The treatment schedules for both groups were of similar duration and frequency. Improvements were evaluated using three indicators: 1) The Brunnström-Fugl-Meyer (FM) test, 2) the Box and Blocks (B&B) test and 3) improvement parameters as determined by the HandTutorTM software. Following 15 consecutive treatment sessions, a signifi cant improvement was observed within the experimental group (95% confi dence intervals) compared with the control group: B&B p = 0.015; FM p = 0.041, HandTutor™ performance accuracy on x axis and performance accuracy on y axis p < 0.0003. The results from this pilot study support further investigation of the use of the HandTutorTM in combination with traditional occupational therapy and physiotherapy during post stroke hand function rehabilitation.

  12. Hypnotic clever hands: Agency and automatic responding.

    PubMed

    Polito, Vince; Barnier, Amanda J; Connors, Michael H

    2018-06-01

    The Clever Hands task (Wegner, Fuller, & Sparrow, 2003) is a behavioral illusion in which participants make responses to a trivia quiz for which they have no sense of agency. Sixty high hypnotizable participants completed two versions of the Clever Hands task. Quiz One was a replication of the original study. Quiz Two was a hypnotic adaptation using three suggestions that were based on clinical disruptions to the sense of agency. The suggestions were for: random responding, thought insertion, and alien control. These suggestions led to differences in accuracy (action production) and estimates of accuracy (action projection). Specifically, whereas the random responding suggestion had little effect, the two clinically based suggestions had opposite impacts on action production: the thought insertion suggestion led to an increase in the rate of correct responses (although participants still believed they were responding randomly); while the alien control suggestion led to a reduction in the rate of correct answers and a pattern of results that more closely approximated randomness. Contrary to theoretical accounts that claim that hypnosis affects executive monitoring rather than executive control, this result indicates that specific hypnotic suggestions can also influence the implicit processes involved in action production. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  13. 46 CFR 160.047-6 - Marking.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... when wet. Do not snag or puncture inner plastic cover. If pads become waterlogged, replace device... buoyant vests shall be sufficiently waterproof so that after 72 hours submergence in water, it will withstand vigorous rubbing by hand while wet without the printed matter becoming illegible. [CGD 72-163R, 38...

  14. Hand Therapy

    MedlinePlus

    ... a scar Find a hand surgeon near you. Videos Figures Figure 1: Examples of hand splints PDF ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  15. Gene expression analysis of enzymes of the carotenoid biosynthesis pathway involved in β-cryptoxanthin accumulation in wild raspberry, Rubus palmatus.

    PubMed

    Mizuno, Kouichi; Tokiwano, Tetsuo; Yoshizawa, Yuko

    2017-03-18

    β-cryptoxanthin (β-Cry), a xanthophyll, is unlike other abundant carotenoids, such as α-carotene, β-carotene, lycopene, lutein, and zeaxanthin. It is not found in most fruits or vegetables but is found only in specific fruits, such as hot chili pepper, persimmon, and citrus fruits. Because recent reports suggest that β-Cry intake is beneficial to human health, the xanthophyll requires further investigation. Although β-Cry accumulates in the fruit of wild raspberry, Rubus palmatus, it is not present in cultivated raspberry. In the present study, two wild raspberry species were studied-R. palmatus, which accumulates β-Cry in the fruit, and R. crataegifolius, which does not accumulate β-Cry. Four carotenoid biosynthetic enzymes derived from these two species were analyzed-phytoene synthase (PSY), lycopene β-cyclase (LCYb), β-carotene hydroxylase (HYb), and zeaxanthin epoxidase (ZEP). Expression levels of their genes were also assessed to elucidate mechanism underlying β-Cry accumulation. Partial gene sequences of RubPSY, RubLCYb, RubHYb, and RubZEP, isolated from immature raspberry fruits of R. palmatus, were used as probes for Northern blot analysis. RubZEP expression ceased as the fruits matured, possibly because of reduced production of zeaxanthin. β-Cry is considered to be an intermediate compound that accumulates in the mature fruits of R. palmatus. High expression of RubPSY was detectable in the mature fruits of R. crataegifolius, and the expression of RubLCYb, RubHYb, and RubZEP was detectable during all stages of fruit maturation. In contrast, β-Cry was absent in the mature fruits of R. crataegifolius. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Second-hand market as an alternative in reverse logistics

    NASA Astrophysics Data System (ADS)

    Pochampally, Kishore K.; Gupta, Surendra M.

    2004-02-01

    Collectors of discarded products seldom know when those products were bought and why they are discarded. Also, the products do not indicate their remaining life periods. So, it is difficult to decide if it is "sensible" to repair (if necessary) a particular product for subsequent sale on the second-hand market or to disassemble it partially or completely for subsequent remanufacture and/or recycle. To this end, we build an expert system using Bayesian updating process and fuzzy set theory, to aid such decision-making. A numerical example demonstrates the building approach.

  17. The evolution of functional hand replacement: From iron prostheses to hand transplantation

    PubMed Central

    Zuo, Kevin J; Olson, Jaret L

    2014-01-01

    The hand is an integral component of the human body, with an incredible spectrum of functionality. In addition to possessing gross and fine motor capabilities essential for physical survival, the hand is fundamental to social conventions, enabling greeting, grooming, artistic expression and syntactical communication. The loss of one or both hands is, thus, a devastating experience, requiring significant psychological support and physical rehabilitation. The majority of hand amputations occur in working-age males, most commonly as a result of work-related trauma or as casualties sustained during combat. For millennia, humans have used state-of-the-art technology to design clever devices to facilitate the reintegration of hand amputees into society. The present article provides a historical overview of the progress in replacing a missing hand, from early iron hands intended primarily for use in battle, to today’s standard body-powered and myoelectric prostheses, to revolutionary advancements in the restoration of sensorimotor control with targeted reinnervation and hand transplantation. PMID:25152647

  18. From Auto- to Allotransplantation: Immunomodulatory Protocol for Hand and Arm Transplantation.

    PubMed

    Lee, W P Andrew; Shores, Jaimie T; Brandacher, Gerald

    2018-05-18

     To achieve a favorable risk-benefit balance for hand transplantation, an immunomodulatory protocol was developed in the laboratory and translated to clinical application.  Following donor bone marrow infusion into transplant recipients, hand and arm allografts have been maintained on low-dose tacrolimus monotherapy.  Good-to-excellent functional recovery has been achieved in patients compliant with medication and therapy, thus restoring autonomous and productive lives.  The risk-benefit balance can be tilted in favor of the hand transplant recipients by using an immunomodulatory protocol with minimum immunosuppression. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Chubby hands or little fingers: sex differences in hand representation.

    PubMed

    Coelho, Lara A; Gonzalez, Claudia L R

    2018-04-03

    Disturbed body representation is a condition defined by the perception that one's body size is different from their anatomical size. While equal amounts of males and females suffer from disturbed body representation, there appear to be differences in the direction of this distortion. Females will typically overestimate, whereas males will typically underestimate body size. One part of the body that has been consistently misperceived is the hands. This misrepresentation consists of two distinct characteristics: an overestimation of hand width, and an underestimation of finger length. Many of these studies, however, have used predominately female participants, allowing for the possibility that women are driving this distortion. The aim of the present study was to examine possible sex differences in hand perception. To this end, participants estimated the location of ten landmarks on their hands when their hands were hidden from view. Our results indicate that females follow the characteristic distortion, whereas males only underestimate finger length (albeit more than females). These findings are surprising, because the hands are not an area of concern for weight gain/loss. We discuss these findings in relation to body dysmorphia literature.

  20. Dextrous robot hands

    NASA Technical Reports Server (NTRS)

    Venkataraman, Subramanian T. (Editor); Iberall, Thea (Editor)

    1990-01-01

    Recent studies of human hand function and their implications for the design of robot hands are discussed in reviews and reports. Topics addressed include human grasp choice and robotic grasp analysis, opposition space and human prehension, coordination in normal and prosthetic reaching, and intelligent exploration by the human hand. Consideration is given to a task-oriented dextrous manipulation architecture, the control architecture for the Belgrade/USC hand, the analysis of multifingered grasping and manipulation, and tactile sensing for shape interpretation. Diagrams, graphs, and photographs are provided.

  1. In a demanding task, three-handed manipulation is preferred to two-handed manipulation

    NASA Astrophysics Data System (ADS)

    Abdi, Elahe; Burdet, Etienne; Bouri, Mohamed; Himidan, Sharifa; Bleuler, Hannes

    2016-02-01

    Equipped with a third hand under their direct control, surgeons may be able to perform certain surgical interventions alone; this would reduce the need for a human assistant and related coordination difficulties. However, does human performance improve with three hands compared to two hands? To evaluate this possibility, we carried out a behavioural study on the performance of naive adults catching objects with three virtual hands controlled by their two hands and right foot. The subjects could successfully control the virtual hands in a few trials. With this control strategy, the workspace of the hands was inversely correlated with the task velocity. The comparison of performance between the three and two hands control revealed no significant difference of success in catching falling objects and in average effort during the tasks. Subjects preferred the three handed control strategy, found it easier, with less physical and mental burden. Although the coordination of the foot with the natural hands increased trial after trial, about two minutes of practice was not sufficient to develop a sense of ownership towards the third arm.

  2. In a demanding task, three-handed manipulation is preferred to two-handed manipulation.

    PubMed

    Abdi, Elahe; Burdet, Etienne; Bouri, Mohamed; Himidan, Sharifa; Bleuler, Hannes

    2016-02-25

    Equipped with a third hand under their direct control, surgeons may be able to perform certain surgical interventions alone; this would reduce the need for a human assistant and related coordination difficulties. However, does human performance improve with three hands compared to two hands? To evaluate this possibility, we carried out a behavioural study on the performance of naive adults catching objects with three virtual hands controlled by their two hands and right foot. The subjects could successfully control the virtual hands in a few trials. With this control strategy, the workspace of the hands was inversely correlated with the task velocity. The comparison of performance between the three and two hands control revealed no significant difference of success in catching falling objects and in average effort during the tasks. Subjects preferred the three handed control strategy, found it easier, with less physical and mental burden. Although the coordination of the foot with the natural hands increased trial after trial, about two minutes of practice was not sufficient to develop a sense of ownership towards the third arm.

  3. 46 CFR 160.049-6 - Marking.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... material provides a minimum buoyant force of 20 lb. Dry out thoroughly when wet. Approved for use on... cushions shall be sufficiently waterproof so that after 72 hours submergence in water, it will withstand vigorous rubbing by hand while wet without the printed matter becoming illegible. [CGFR 65-37, 30 FR 11588...

  4. 46 CFR 160.049-6 - Marking.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... material provides a minimum buoyant force of 20 lb. Dry out thoroughly when wet. Approved for use on... cushions shall be sufficiently waterproof so that after 72 hours submergence in water, it will withstand vigorous rubbing by hand while wet without the printed matter becoming illegible. [CGFR 65-37, 30 FR 11588...

  5. Apparatus Review.

    ERIC Educational Resources Information Center

    Byrum, David L.

    1982-01-01

    Suggests uses for and possible adaptations of a set of semiflexible molecular models. Includes price and supplier information. Also suggests rubbing oil from human face/hands along the pouring lip of a beaker, allowing one to pour uniformly from the beaker spout and making the process as dripless as possible. (Author/JN)

  6. Evidence for right-hand feeding biases in a left-handed population.

    PubMed

    Flindall, Jason W; Stone, Kayla D; Gonzalez, Claudia L R

    2015-05-01

    We have recently shown that actions with similar kinematic requirements, but different end-state goals may be supported by distinct neural networks. Specifically, we demonstrated that when right-handed individuals reach-to-grasp food items with intent to eat, they produce smaller maximum grip apertures (MGAs) than when they grasp the same item with intent to place it in a location near the mouth. This effect was restricted to right-handed movements; left-handed movements showed no difference between tasks. The current study investigates whether (and to which side) the effect may be lateralized in left-handed individuals. Twenty-one self-identified left-handed participants grasped food items of three different sizes while grasp kinematics were captured via an Optotrak Certus motion capture array. A main effect of task was identified wherein the grasp-to-eat action generated significantly smaller MGAs than did the grasp-to-place action. Further analysis revealed that similar to the findings in right-handed individuals, this effect was significant only during right-handed movements. Upon further inspection however, we found individual differences in the magnitude and direction of the observed lateralization. These results underscore the evolutionary significance of the grasp-to-eat movement in producing population-level right-handedness in humans as well as highlighting the heterogeneity of the left-handed population.

  7. Hand function in workers with hand-arm vibration syndrome.

    PubMed

    Cederlund, R; Isacsson, A; Lundborg, G

    1999-01-01

    Hand-arm vibration syndrome has been specially addressed in the Scandinavian countries in recent years, but the syndrome is still not sufficiently recognized in many countries. The object of this preliminary study was to describe the nature and character of vibration-induced impairment in the hands of exposed workers. Twenty symptomatic male workers (aged 28 to 65 years) subjected to vibration by hand-held tools were interviewed about subjective symptoms and activities of daily living and were assessed with a battery of objective tests for sensibility, dexterity, grip function, and grip strength. The test results were compared with normative data. The majority of patients complained of cold intolerance, numbness, pain, sensory impairment, and difficulties in handling manual tools and in handwriting. The various objective tests showed considerable variation in indications of pathologic outcome, revealing differences in sensitivity to detect impaired hand function. Semmes-Weinstein monofilament testing for perception of light touch-deep pressure sensation, the small-object shape identification test, and moving two-point discrimination testing for functional sensibility provided the most indications of pathologic outcomes. The authors conclude that vibration-exposed patients present considerable impairment in hand function.

  8. Reported Adverse Health Effects in Children from Ingestion of Alcohol-Based Hand Sanitizers - United States, 2011-2014.

    PubMed

    Santos, Cynthia; Kieszak, Stephanie; Wang, Alice; Law, Royal; Schier, Joshua; Wolkin, Amy

    2017-03-03

    Hand sanitizers are effective and inexpensive products that can reduce microorganisms on the skin, but ingestion or improper use can be associated with health risks. Many hand sanitizers contain up to 60%-95% ethanol or isopropyl alcohol by volume, and are often combined with scents that might be appealing to young children. Recent reports have identified serious consequences, including apnea, acidosis, and coma in young children who swallowed alcohol-based (alcohol) hand sanitizer (1-3). Poison control centers collect data on intentional and unintentional exposures to hand sanitizer solutions resulting from various routes of exposure, including ingestion, inhalation, and dermal and ocular exposures. To characterize exposures of children aged ≤12 years to alcohol hand sanitizers, CDC analyzed data reported to the National Poison Data System (NPDS).* The major route of exposure to both alcohol and nonalcohol-based (nonalcohol) hand sanitizers was ingestion. The majority of intentional exposures to alcohol hand sanitizers occurred in children aged 6-12 years. Alcohol hand sanitizer exposures were associated with worse outcomes than were nonalcohol hand sanitizer exposures. Caregivers and health care providers should be aware of the potential dangers associated with hand sanitizer ingestion. Children using alcohol hand sanitizers should be supervised and these products should be kept out of reach from children when not in use.

  9. Determinants of hand hygiene compliance in Egypt: building blocks for a communication strategy.

    PubMed

    Lohiniva, A-L; Bassim, H; Hafez, S; Kamel, E; Ahmed, E; Saeed, T; Talaat, M

    2015-10-02

    Hand hygiene of health-care staff is one of the most important interventions in reducing transmission of nosocomial infections. This qualitative study aimed to understand the behavioural determinants of hand hygiene in order to develop sustainable interventions to promote hand hygiene in hospitals. Fourteen focus group discussions were conducted with nurses in 2 university hospitals in Egypt. The interviews were tape recorded and transcribed. Thematic analysis was conducted by 2 independent investigators. The findings highlighted that nurses did not perceive the benefits of hand hygiene, and that they linked the need to wash hands to a sense of dirtiness. Knowledge of hand hygiene and related products was limited and preference for water and soap was obvious. Environmental constraints, lack of role models and social control were identified as barriers for compliance with hand hygiene. A multi-faceted hand hygiene strategy was developed based on existing cultural concepts valued by the hospital staff.

  10. Hand in Hand: Media Literacy and Internet Safety

    ERIC Educational Resources Information Center

    Gallagher, Frank

    2011-01-01

    Internet safety cannot be effectively taught without also teaching media literacy. The two go hand in hand, and both are necessary, but neither is sufficient. To understand why, it is important to first appreciate what the real risks to children are. Many of the early Internet safety programs were based on a fear of predators. Predators turned out…

  11. Hands-free human-machine interaction with voice

    NASA Astrophysics Data System (ADS)

    Juang, B. H.

    2004-05-01

    Voice is natural communication interface between a human and a machine. The machine, when placed in today's communication networks, may be configured to provide automation to save substantial operating cost, as demonstrated in AT&T's VRCP (Voice Recognition Call Processing), or to facilitate intelligent services, such as virtual personal assistants, to enhance individual productivity. These intelligent services often need to be accessible anytime, anywhere (e.g., in cars when the user is in a hands-busy-eyes-busy situation or during meetings where constantly talking to a microphone is either undersirable or impossible), and thus call for advanced signal processing and automatic speech recognition techniques which support what we call ``hands-free'' human-machine communication. These techniques entail a broad spectrum of technical ideas, ranging from use of directional microphones and acoustic echo cancellatiion to robust speech recognition. In this talk, we highlight a number of key techniques that were developed for hands-free human-machine communication in the mid-1990s after Bell Labs became a unit of Lucent Technologies. A video clip will be played to demonstrate the accomplishement.

  12. Death caused by ingestion of an ethanol-based hand sanitizer.

    PubMed

    Schneir, Aaron B; Clark, Richard F

    2013-09-01

    The use of hand sanitizer is effective in preventing the transmission of disease. Many hand sanitizers are alcohol-based, and significant intoxications have occurred, often in health care facilities, including the emergency department (ED). We present this case to highlight potential toxicity after the ingestion of an ethanol-based hand sanitizer. A 36-year-old man presented to the ED with ethanol intoxication. Ethanol breath analysis was measured at 278 mg/dL. After 4 h, the patient was less intoxicated and left the ED. Thirty minutes later, he was found apneic and pulseless in the ED waiting room bathroom after having ingested an ethanol-based hand sanitizer. Soon after a brief resuscitation, his serum ethanol was 526 mg/dL. He never regained consciousness and died 7 days later. No other cause of death was found. The case highlights the potential for significant toxicity after the ingestion of a product found throughout health care facilities. Balancing the benefit of hand sanitizers for preventing disease transmission and their potential misuse remains a challenge. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. New non-alcoholic formulation for hand disinfection.

    PubMed

    Biagi, Marco; Giachetti, Daniela; Miraldi, Elisabetta; Figura, Natale

    2014-04-01

    Hand washing is considered as the single most important strategy to prevent infections. World health organization (WHO) defines hand hygiene as a primary issue of personal care with particular reference to hospital personnel and health facility workers. In this work, we investigated a new combination for hand disinfection as an alternative to alcohol-based and chlorhexidine products. The new combination of 5-pyrrolidone-2-carboxylic acid (PCA) and copper sulphate pentahydrate (CS) was tested upon different bacterial species that normally colonize hands, including Staphylococcus aureus, methicillin resistant S. aureus (MR S. aureus), Staphylococcus epidermidis, multidrug resistant S. epidermidis (MDR S. epidermidis), Streptococcus pyogenes, Streptococcus agalactiae, Escherichia coli, Candida albicans and three clinical isolates: MR S. aureus, MDR S. epidermidis, and an E. coli strain. Minimal inhibitory concentrations (MICs), Minimal bactericidal concentrations (MBCs), fractional inhibitory concentration (FIC) indices, and fractional bactericidal concentration (FBC) indices were evaluated. Ethanol 70% V/V, isopropanol 60% V/V, and 4% w/V chlorhexidine solution were used as reference hand disinfectants. Copper sulphate pentahydrate was very effective against all tested microorganisms: The MIC and MBC for CS ranged from 781 mg/l against S. pyogenes to 12500 mg/l against E. coli strains and C. albicans. In addition, PCA exhibited a good antimicrobial activity, in particular, against S. pyogenes and S. agalactiae. The combination of CS and PCA showed a strong synergistic effect and all FIC indices were ≤0·500. The combination of CS and PCA were more effective than ethanol 70% V/V and isopropanol 60% V/V. In addition to antimicrobial activity, the new formulation possesses peculiar features such as residual activity and moisturizing effect. This work identifies a new strategy for hand disinfection.

  14. Hand Eczema

    PubMed Central

    Agarwal, Uma Shankar; Besarwal, Raj Kumar; Gupta, Rahul; Agarwal, Puneet; Napalia, Sheetal

    2014-01-01

    Hand eczema is often a chronic, multifactorial disease. It is usually related to occupational or routine household activities. Exact etiology of the disease is difficult to determine. It may become severe enough and disabling to many of patients in course of time. An estimated 2-10% of population is likely to develop hand eczema at some point of time during life. It appears to be the most common occupational skin disease, comprising 9-35% of all occupational diseases and up to 80% or more of all occupational contact dermatitis. So, it becomes important to find the exact etiology and classification of the disease and to use the appropriate preventive and treatment measures. Despite its importance in the dermatological practice, very few Indian studies have been done till date to investigate the epidemiological trends, etiology, and treatment options for hand eczema. In this review, we tried to find the etiology, epidemiology, and available treatment modalities for chronic hand eczema patients. PMID:24891648

  15. [Agraphia of the left hand--its characteristics and mechanism of development].

    PubMed

    Ohigashi, Y; Hamanaka, T; Asano, K; Morimune, S

    1983-11-01

    We observed 62 y.o. right-handed woman, whose truncus of corps callosum was damaged by infarction of left anterior cerebral artery, that was verified by coronal CT scan finding. She was apraxic and agraphic only with left hand. We examined the characteristics of her unilateral left agraphia from the point of quantitative and qualitative views. These analysis seemed to reveal three main characteristics of unilateral left agraphia of this patient. These were as follows; 1) productive, 2) neographic and 3) iterative. Another important feature of this patient was the mute state during her left-hand writing. Her left agraphia could not explained by apraxic factor, because her copying capacity was remarkably preserved in comparison with her dictation or written naming ability. Furthermore, this agraphia was not aphasic because her right-hand writing was almost intact. We agreed with Yamadori who insisted that this type of agraphia was neither apraxic nor aphasic, but the particular third agraphia which was named as "disconnection agraphia". We considered that the mute state during her left-hand writing might some kind of transient aphasia, which may reflect the functional disturbance of left hemisphere, and the reduced energy in the left hemisphere could increase the activity of right hemisphere. Partial interhemispheric disconnection might induce transient "linguistic anosognosia" in this patient. We believe that these transient hyperactivity and transient linguistic anosognosia could generate above mentioned characteristics of her left agraphia; productive, neographic and iterative.

  16. Keep your hands crossed: the valence-by-left/right interaction is related to hand, not side, in an incongruent hand-response key assignment.

    PubMed

    de la Vega, Irmgard; Dudschig, Carolin; De Filippis, Mónica; Lachmair, Martin; Kaup, Barbara

    2013-02-01

    The body-specificity hypothesis (Casasanto, 2009) associates positive emotional valence and the space surrounding the dominant hand, and negative valence and the space surrounding the non-dominant hand. This effect has not only been found for manual responses, but also for the left and right side. In the present study, we investigated whether this compatibility effect still shows when hand and side carry incongruent information, and whether it is then related to hand or to side. We conducted two experiments which used an incongruent hand-response key assignment, that is, participants had their hands crossed. Participants were instructed to respond with their right vs. left hand (Experiment 1) or with the right vs. left key (Experiment 2). In both experiments, a compatibility effect related to hand emerged, indicating that the association between hand and valence overrides the one between side and valence when hand and side carry contradicting information. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Rett syndrome

    PubMed Central

    Sitholey, Prabhat; Agarwal, Vivek; Srivastava, Rohit

    2005-01-01

    Rett syndrome is a rare, progressive, neurodevelopmental disorder that has been reported only in the girl child. We describe the case of a 6.9-year-old girl with Rett syndrome. She had normal development till the age of 2 years. However, over the next 4–5 months, she lost her acquired, purposeful hand skills; expressive and receptive language; and reciprocal social interaction; and gradually developed a broad-based gait and typical midline stereotyped hand movements (mouthing, rubbing). PMID:20711295

  18. Assessment of two hand hygiene regimens for intensive care unit personnel.

    PubMed

    Larson, E L; Aiello, A E; Bastyr, J; Lyle, C; Stahl, J; Cronquist, A; Lai, L; Della-Latta, P

    2001-05-01

    To compare skin condition and skin microbiology among intensive care unit personnel using one of two randomly assigned hand hygiene regimens: a 2% chlorhexidine gluconate (CHG)-containing traditional antiseptic wash and a waterless handrub containing 61% ethanol with emollients (ALC). Prospective, randomized clinical trial. Two critical care units (medical and surgical) in a large, metropolitan academic health center in Manhattan. Fifty staff members (physicians, nurses, housekeepers, respiratory therapists) working full time in the intensive care unit. One of two hand hygiene regimens randomly assigned for four consecutive weeks. The two outcomes were skin condition (measured by two tools: Hand Skin Assessment form and Visual Skin Scaling form) and skin microbiology. Samples were obtained at baseline, on day 1, and at the end of wks 2 and 4. Participants in the ALC group had significant improvements in the Hand Skin Assessment scores at wk 4 (p = 0.04) and in Visual Skin Scaling scores at wks 3 (p = 0.01) and 4 (p = 0.0005). There were no significant differences in numbers of colony-forming units between participants in the CHG or ALC group at any time period. The ALC regimen required significantly less time than the CHG regimen (mean: 12.7 secs and 21.1 secs, respectively; p = 0.000) and resulted in a 50% reduction in material costs. Changes in hand hygiene practices in acute care settings from the traditional antiseptic wash to use of plain, mild soap and an alcohol-based product should be considered. Further research is needed to examine the association between use of antiseptic products for hand hygiene of staff and reductions in nosocomial infection rates among patients.

  19. The Effect of Antibacterial Formula Hand Cleaners on the Elimination of Microbes on Hands

    NASA Astrophysics Data System (ADS)

    Coleman, J. R.

    2002-05-01

    : The purpose of this project is to find out which one of the antibacterial hand cleanser (antibacterial bar soap, antibacterial liquid hand soap, and liquid hand sanitizer) is more effective in eliminating microbes. If antibacterial- formula liquid hand soap is used on soiled hands, then it will be more effective in eliminating microbes. Germs are microorganisms that cause disease and can spread from person-to-person. Bacteria are a kind of microbe, an example of which is Transient Flora that is often found on hands. Hand washing prevents germs from spreading to others. During the procedure, swabs were used to take samples before and after the soiled hands had been washed with one of the antibacterial hand cleansers. Nutrient Easygel was poured into petri dishes to harden for 1 day, and then samples were swabbed on the gel. The Petri dishes were placed in an incubator for 24 hours, and then data was recorded accordingly. The antibacterial liquid hand soap was sufficient in eliminating the majority of bacteria. The hands had 65% of the bacteria on them, and after the liquid hand soap was used only 37% of the bacteria remained.

  20. Ability of Hand Hygiene Interventions Using Alcohol-Based Hand Sanitizers and Soap To Reduce Microbial Load on Farmworker Hands Soiled during Harvest.

    PubMed

    de Aceituno, Anna Fabiszewski; Bartz, Faith E; Hodge, Domonique Watson; Shumaker, David J; Grubb, James E; Arbogast, James W; Dávila-Aviña, Jorgé; Venegas, Fabiola; Heredia, Norma; García, Santos; Leon, Juan S

    2015-11-01

    Effective hand hygiene is essential to prevent the spread of pathogens on produce farms and reduce foodborne illness. The U.S. Food and Drug Administration Food Safety Modernization Act Proposed Rule for Produce Safety recommends the use of soap and running water for hand hygiene of produce handlers. The use of alcohol-based hand sanitizer (ABHS) may be an effective alternative hygiene intervention where access to water is limited. There are no published data on the efficacy of either soap or ABHS-based interventions to reduce microbial contamination in agricultural settings. The goal of this study was to assess the ability of two soap-based (traditional or pumice) and two ABHS-based (label-use or two-step) hygiene interventions to reduce microbes (coliforms, Escherichia coli, and Enterococcus spp.) and soil (absorbance of hand rinsate at 600 nm [A600]) on farmworker hands after harvesting produce, compared with the results for a no-hand-hygiene control. With no hand hygiene, farmworker hands were soiled (median A600, 0.48) and had high concentrations of coliforms (geometric mean, 3.4 log CFU per hand) and Enterococcus spp. (geometric mean, 5.3 log CFU per hand) after 1 to 2 h of harvesting tomatoes. Differences in microbial loads in comparison to the loads in the control group varied by indicator organism and hygiene intervention (0 to 2.3 log CFU per hand). All interventions yielded lower concentrations of Enterococcus spp. and E. coli (P < 0.05), but not of coliforms, than were found in the control group. The two-step ABHS intervention led to significantly lower concentrations of coliforms and Enterococcus spp. than the pumice soap and label-use ABHS interventions (P < 0.05) and was the only intervention to yield significantly fewer samples with E. coli than were found in the control group (P < 0.05). All interventions removed soil from hands (P < 0.05), soap-based interventions more so than ABHS-based interventions (P < 0.05). ABHS-based interventions were

  1. 46 CFR 160.052-8 - Marking.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) provides a minimum buoyant force of (151/2 lb., 11 lb., or 7 lb.). Dry out thoroughly when wet. Approved... vests shall be sufficiently waterproof so that after 72 hours submergence in water it will withstand vigorous rubbing by hand while wet without the printed matter becoming illegible. [CGD 72-163R, 38 FR 8120...

  2. Compact Telerobot Hand

    NASA Technical Reports Server (NTRS)

    Rosheim, Mark; Trechsel, Hans

    1993-01-01

    Anthropomorphic telerobotic hand contains actuators, joints, sensors, and complex wiring harnesses. Glove protects interior components of hand from dirt and damage. Imitates motions of human fingers and wrist in lifelike and dexterous way. Incorporates pitch/yaw joints in wrist and head knuckles. Hand modular; so fingers removable, interchangeable units. Feature simplifies servicing and maintenance, which must be done frequently in such complex mechanism.

  3. Association of hand and arm disinfection with asthma control in US nurses.

    PubMed

    Dumas, Orianne; Varraso, Raphäelle; Boggs, Krislyn M; Descatha, Alexis; Henneberger, Paul K; Quinot, Catherine; Speizer, Frank E; Zock, Jan-Paul; Le Moual, Nicole; Camargo, Carlos A

    2018-05-01

    To investigate the association between occupational exposure to disinfectants/antiseptics used for hand hygiene and asthma control in nurses. In 2014, we invited female nurses with asthma drawn from the Nurses' Health Study II to complete two supplemental questionnaires on their occupation and asthma (cross-sectional study, response rate: 80%). Among 4055 nurses (mean age: 59 years) with physician-diagnosed asthma and asthma medication use in the past year, we examined asthma control, as defined by the Asthma Control Test (ACT). Nurses were asked about the daily frequency of hand hygiene tasks: 'wash/scrub hands with disinfectants/hand sanitizers' (hand hygiene) and 'wash/scrub arms with disinfecting products' (surrogate of surgical hand/arm antisepsis). Analyses were adjusted for age, race, ethnicity, smoking status and body mass index. Nurses with partly controlled asthma (ACT: 20-24, 50%) and poorly controlled asthma (ACT ≤19, 18%) were compared with nurses with controlled asthma (ACT=25, 32%). In separate models, both hand and arm hygiene were associated with poorly controlled asthma. After mutual adjustment, only arm hygiene was associated with poorly controlled asthma: OR (95% CI) for <1 time/day, 1.38 (1.06 to 1.80); ≥1 time/day, 1.96 (1.52 to 2.51), versus never. We observed a consistent dose-response relationship between frequency of arm hygiene tasks (never to >10 times/day) and poor asthma control. Associations persisted after further adjustment for surfaces/instruments disinfection tasks. Frequency of hand/arm hygiene tasks in nurses was associated with poor asthma control. The results suggest an adverse effect of products used for surgical hand/arm antisepsis. This potential new occupational risk factor for asthma warrants further study. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. The Research and Implementation of Vehicle Bluetooth Hands-free Devices Key Parameters Downloading Algorithm

    NASA Astrophysics Data System (ADS)

    Zhang, Xiao-bo; Wang, Zhi-xue; Li, Jian-xin; Ma, Jian-hui; Li, Yang; Li, Yan-qiang

    In order to facilitate Bluetooth function realization and information can be effectively tracked in the process of production, the vehicle Bluetooth hands-free devices need to download such key parameters as Bluetooth address, CVC license and base plate numbers, etc. Therefore, it is the aim to search simple and effective methods to download parameters for each vehicle Bluetooth hands-free device, and to control and record the use of parameters. In this paper, by means of Bluetooth Serial Peripheral Interface programmer device, the parallel port is switched to SPI. The first step is to download parameters is simulating SPI with the parallel port. To perform SPI function, operating the parallel port in accordance with the SPI timing. The next step is to achieve SPI data transceiver functions according to the programming parameters of options. Utilizing the new method, downloading parameters is fast and accurate. It fully meets vehicle Bluetooth hands-free devices production requirements. In the production line, it has played a large role.

  5. Use of a verbal electronic audio reminder with a patient hand hygiene bundle to increase independent patient hand hygiene practices of older adults in an acute care setting.

    PubMed

    Knighton, Shanina C; Dolansky, Mary; Donskey, Curtis; Warner, Camille; Rai, Herleen; Higgins, Patricia A

    2018-06-01

    We hypothesized that the addition of a novel verbal electronic audio reminder to an educational patient hand hygiene bundle would increase performance of self-managed patient hand hygiene. We conducted a 2-group comparative effectiveness study randomly assigning participants to patient hand hygiene bundle 1 (n = 41), which included a video, a handout, and a personalized verbal electronic audio reminder (EAR) that prompted hand cleansing at 3 meal times, or patient hand hygiene bundle 2 (n = 34), which included the identical video and handout, but not the EAR. The primary outcome was alcohol-based hand sanitizer use based on weighing bottles of hand sanitizer. Participants that received the EAR averaged significantly more use of hand sanitizer product over the 3 days of the study (mean ± SD, 29.97 ± 17.13 g) than participants with no EAR (mean ± SD, 10.88 ± 9.27 g; t 73  = 5.822; P ≤ .001). The addition of a novel verbal EAR to a patient hand hygiene bundle resulted in a significant increase in patient hand hygiene performance. Our results suggest that simple audio technology can be used to improve patient self-management of hand hygiene. Future research is needed to determine if the technology can be used to promote other healthy behaviors, reduce infections, and improve patient-centered care without increasing the workload of health care workers. Published by Elsevier Inc.

  6. The founder of Vicks: Lunsford Richardson (1854-1919).

    PubMed

    Al Aboud, Khalid

    2010-01-01

    Vicks VapoRub (Procter & Gamble, Cincinnati, OH) is one of the most popular over-the-counter therapies in the world, used to provide relief from the symptoms of the common cold and non-life-threatening respiratory infections. Even as more advanced products have come and gone, VapoRub continues to dominate the market almost 9 decades after the death of its formulator, Lunsford Richardson (Figure).

  7. Left-handed and right-handed U(1) gauge symmetry

    NASA Astrophysics Data System (ADS)

    Nomura, Takaaki; Okada, Hiroshi

    2018-01-01

    We propose a model with the left-handed and right-handed continuous Abelian gauge symmetry; U(1) L × U(1) R . Then three right-handed neutrinos are naturally required to achieve U(1) R anomaly cancellations, while several mirror fermions are also needed to do U(1) L anomaly cancellations. Then we formulate the model, and discuss its testability of the new gauge interactions at collider physics such as the large hadron collider (LHC) and the international linear collider (ILC). In particular, we can investigate chiral structure of the interactions by the analysis of forward-backward asymmetry based on polarized beam at the ILC.

  8. Reduction in finger blood flow induced by hand-transmitted vibration: effect of hand elevation.

    PubMed

    Ye, Ying; Mauro, Marcella; Bovenzi, Massimo; Griffin, Michael J

    2015-10-01

    This study investigated the effect of hand elevation on reductions in finger blood flow (FBF) induced by hand-transmitted vibration. Fourteen males attended six sessions on six separate days, with a control sessions and a vibration session (125-Hz vibration at 44 ms(-2) rms) with the right hand supported at each of three elevations: 20 cm below heart level (HL), at HL, and 20 cm above HL. Finger blood flow on the left and right hand was measured every 30 s during each 25-min session comprised of five periods: (1) no force and no vibration (5 min), (2) 2-N force and no vibration (5 min), (3) 2-N force and vibration (5 min), (4) 2-N force and no vibration (5 min), and (5) no force and no vibration (5 min). Without vibration, FBF decreased with increasing elevation of the hand. During vibration of the right hand, FBF reduced on both hands. With elevation of the right hand, the percentage reduction in FBF due to vibration (relative to FBF on the same finger at the same elevation before exposure to vibration) was similar on the middle and little fingers of both hands. After cessation of vibration, there was delayed return of FBF with all three hand heights. Vibration of one hand reduces FBF on both exposed and unexposed hands, with the reduction dependent on the elevation of the hand. The mechanisms responsible for vibration-induced reductions in FBF seem to reduce blood flow as a percentage of the blood flow without vibration. Tasks requiring the elevation of the hands will be associated with lower FBF, and the FBF will be reduced further if there is exposure to hand-transmitted vibration.

  9. Efficacy of alcohol-based hand sanitizer on hands soiled with dirt and cooking oil.

    PubMed

    Pickering, Amy J; Davis, Jennifer; Boehm, Alexandria B

    2011-09-01

    Handwashing education and promotion are well established as effective strategies to reduce diarrhea and respiratory illness in countries around the world. However, access to reliable water supplies has been identified as an important barrier to regular handwashing in low-income countries. Alcohol-based hand sanitizer (ABHS) is an effective hand hygiene method that does not require water, but its use is not currently recommended when hands are visibly soiled. This study evaluated the efficacy of ABHS on volunteers' hands artificially contaminated with Escherichia coli in the presence of dirt (soil from Tanzania) and cooking oil. ABHS reduced levels of E. coli by a mean of 2.33 log colony forming units (CFU) per clean hand, 2.32 log CFU per dirt-covered hand, and 2.13 log CFU per oil-coated hand. No significant difference in efficacy was detected between hands that were clean versus dirty or oily. ABHS may be an appropriate hand hygiene method for hands that are moderately soiled, and an attractive option for field settings in which access to water and soap is limited.

  10. Hand anthropometry of Indian women.

    PubMed

    Nag, Anjali; Nag, P K; Desai, Hina

    2003-06-01

    Data on the physical dimension of the hand of Indian women are scanty. This information is necessary to ascertain human-machine compatibility in the design of manual systems for the bare and gloved hand, such as design and sizing of hand tools, controls, knobs and other applications in different kinds of precision and power grips. The present study was undertaken to generate hand anthropometric data of 95 women, working in informal industries (beedi, agarbatti and garment making). Fifty one hand measurements of the right hand (lengths, breadths, circumferences, depths, spreads and clearances of hand and fingers) were taken, using anthropometric sliding and spreading calipers, measuring tape and handgrip strength dynamometer. The data were statistically analyzed to determine the normality of data and the percentile values of different hand dimensions, and simple and multiple regression analysis were done to determine better predictors of hand length and grip strength. The hand breadths, circumferences and depths were approximately normally distributed, with some deviation in case of the finger lengths. Hand length was significantly correlated with the fist, wrist and finger circumferences. The fist and wrist circumferences, in combination, were better predictors of hand length. The hand lengths, breadths and depths, including finger joints of the Indian women studied were smaller than those of American, British and West Indian women. The hand circumferences of the Indian women were also smaller than the American women. Grip strengths of Indian women (20.36 +/- 3.24 kg) were less than those of American, British and West Indian women. Grip strength was found to be statistically significant with hand dimensions, such as hand height perpendicular to wrist crease (digit 5), proximal interphalangeal joint breadth (digit 3) and hand spread across wedge 1. The women who are forced to frequently use cutters, strippers and other tools, which are not optimally designed to

  11. Alcohol-free instant hand sanitizer reduces elementary school illness absenteeism.

    PubMed

    Dyer, D L; Shinder, A; Shinder, F

    2000-10-01

    BACKGROUND AND HYPOTHESES: A substantial percentage of school absenteeism among children is related to transmissible infection. Rates of transmission can be reduced by hand washing with soap and water, but such washing occurs infrequently. This study tested whether an alcohol-free instant hand sanitizer (CleanHands) could reduce illness absenteeism in school-age children. A 10-week, open-label, crossover study was performed on 420 elementary school-age children (ages 5-12). Students were given a brief orientation immediately prior to the start of the study on the relationship of germs, illness, and hand washing. Each student in the treatment group then received the test product in individual bottles, with instructions to apply one to two sprays to the hands after coming into the classroom, before eating, and after using the restroom, in addition to their normal hand washing with soap and water. The control group was instructed to continue hand washing as normal with non-medicated soap. After 4 weeks of treatment and a 2-week wash-out period, the control and experimental groups were reversed. Data gathered on absenteeism were classified as gastrointestinal or respiratory related and normalized for nonillness-related absenteeism and school holidays. Compared to the hand washing-only control group, students using CleanHands were found to have 41.9% fewer illness-related absence days, representing a 28.9% and a 49.7% drop in gastrointestinal- and respiratory-related illnesses, respectively. Likewise, absence incidence decreased by 31.7%, consisting of a 44.2% and 50.2% decrease in incidence of gastrointestinal- and respiratory-related illnesses, respectively. No adverse events were reported during the study. Daily use of the instant hand sanitizer was associated with significantly lower rates of illness-related absenteeism.

  12. Friction. Physical Science in Action[TM]. Schlessinger Science Library. [Videotape].

    ERIC Educational Resources Information Center

    2000

    Most people think friction is what happens when two things are rubbed together. But there's so much more! Friction is a force that resists motion. Yet, without friction, motion would be impossible. Students will learn more about this natural force and the attempts made at controlling it in the world. Includes a hands-on activity and graphic…

  13. From the Gleam in the Eye of an Engineer to a Dream Classroom: How Assistive Technology Products Move from Research and Development into the Hands of Children

    ERIC Educational Resources Information Center

    de St. Aubin, Shawn-Laree

    2010-01-01

    This article explains how Asssistive Technology products move from research and development into the hands of children. The assistive technology (AT) industry is maturing, with many exciting new technologies under development in university settings, by individual inventors and engineers, and by leading AT and information technology (IT) companies.…

  14. Multi-finger synergies and the muscular apparatus of the hand.

    PubMed

    Cuadra, Cristian; Bartsch, Angelo; Tiemann, Paula; Reschechtko, Sasha; Latash, Mark L

    2018-05-01

    We explored whether the synergic control of the hand during multi-finger force production tasks depends on the hand muscles involved. Healthy subjects performed accurate force production tasks and targeted force pulses while pressing against loops positioned at the level of fingertips, middle phalanges, and proximal phalanges. This varied the involvement of the extrinsic and intrinsic finger flexors. The framework of the uncontrolled manifold (UCM) hypothesis was used to analyze the structure of inter-trial variance, motor equivalence, and anticipatory synergy adjustments prior to the force pulse in the spaces of finger forces and finger modes (hypothetical finger-specific control signals). Subjects showed larger maximal force magnitudes at the proximal site of force production. There were synergies stabilizing total force during steady-state phases across all three sites of force production; no differences were seen across the sites in indices of structure of variance, motor equivalence, or anticipatory synergy adjustments. Indices of variance, which did not affect the task (within the UCM), correlated with motor equivalent motion between the steady states prior to and after the force pulse; in contrast, variance affecting task performance did not correlate with non-motor equivalent motion. The observations are discussed within the framework of hierarchical control with referent coordinates for salient effectors at each level. The findings suggest that multi-finger synergies are defined at the level of abundant transformation between the low-dimensional hand level and higher dimensional finger level while being relatively immune to transformations between the finger level and muscle level. The results also support the scheme of control with two classes of neural variables that define referent coordinates and gains in back-coupling loops between hierarchical control levels.

  15. Eye-hand preference in schizophrenia: sex differences and significance for hand function.

    PubMed

    Liu, Yi-Chia; Yang, Yen Kuang; Lee, I Hui; Lin, Keh-Chung; Jeffries, Keith J; Lee, Li-Ching

    2004-06-01

    Hand preference and eye dominance were investigated in 73 (30 women, 43 men) schizophrenic patients and 71 (30 women, 41 men) healthy controls. There were significantly more schizophrenic patients and normal controls who were significantly right-hand dominant. However, schizophrenic patients showed a significant excess of left-eye dominance relative to controls (65.8% vs 29.6%; Odds Ratio= 4.75, p< .001). In addition, female schizophrenic patients showed a higher rate of nonright (either left or inconsistent) eye dominance (80%) than male schizophrenic patients (55.8%) and controls (33.3%). Analysis of hand performance on the Purdue Pegboard Test indicated that schizophrenic patients who showed crossed eye-hand dominance scored higher than did patients without crossed eye-hand dominance.

  16. Is the hand to speech what speech is to the hand?

    PubMed

    Mildner, V

    2000-01-01

    Interference between the manual and the verbal performance on two types of concurrent verbal-manual tasks was studied on a sample of 48 female right-handers. The more complex verbal task (storytelling) affected both hands significantly, the less complex (essentially phonemic) task affected only the right hand, with insignificant negative influence on the left-hand performance. No significant reciprocal effects of the motor task on verbalization were found.

  17. Hands-on Science: Does It Matter What Students' Hands Are On?

    ERIC Educational Resources Information Center

    Triona, Lara M.; Klahr, David

    2007-01-01

    Hands-on science typically uses physical materials to give students first-hand experience in scientific methodologies, but the recent availability of virtual laboratories raises an important question about whether what students' hands are on matters to their learning. The overall findings of two articles that employed simple comparisons of…

  18. Hand aperture patterns in prehension.

    PubMed

    Bongers, Raoul M; Zaal, Frank T J M; Jeannerod, Marc

    2012-06-01

    Although variations in the standard prehensile pattern can be found in the literature, these alternative patterns have never been studied systematically. This was the goal of the current paper. Ten participants picked up objects with a pincer grip. Objects (3, 5, or 7cm in diameter) were placed at 30, 60, 90, or 120cm from the hands' starting location. Usually the hand was opened gradually to a maximum immediately followed by hand closing, called the standard hand opening pattern. In the alternative opening patterns the hand opening was bumpy, or the hand aperture stayed at a plateau before closing started. Two participants in particular delayed the start of grasping with respect to start of reaching, with the delay time increasing with object distance. For larger object distances and smaller object sizes, the bumpy and plateau hand opening patterns were used more often. We tentatively concluded that the alternative hand opening patterns extended the hand opening phase, to arrive at the appropriate hand aperture at the appropriate time to close the hand for grasping the object. Variations in hand opening patterns deserve attention because this might lead to new insights into the coordination of reaching and grasping. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Prism adaptation in alternately exposed hands.

    PubMed

    Redding, Gordon M; Wallace, Benjamin

    2013-08-01

    We assessed intermanual transfer of the proprioceptive realignment aftereffects of prism adaptation in right-handers by examining alternate target pointing with the two hands for 40 successive trials, 20 with each hand. Adaptation for the right hand was not different as a function of exposure sequence order or postexposure test order, in contrast with adaptation for the left hand. Adaptation was greater for the left hand when the right hand started the alternate pointing than when the sequence of target-pointing movements started with the left hand. Also, the largest left-hand adaptation appeared when that hand was tested first after exposure. Terminal error during exposure varied in cycles for the two hands, converging on zero when the right hand led, but no difference appeared between the two hands when the left hand led. These results suggest that transfer of proprioceptive realignment occurs from the right to the left hand during both exposure and postexposure testing. Such transfer reflects the process of maintaining spatial alignment between the two hands. Normally, the left hand appears to be calibrated with the right-hand spatial map, and when the two hands are misaligned, the left-hand spatial map is realigned with the right-hand spatial map.

  20. Further information on the prehistoric representations of human hands in the cave of Gargas

    PubMed Central

    Hooper, Alex

    1980-01-01

    This paper amends and adds recent information to Paul A. Janssens' earlier article on the prehistoric paintings of human hands in the cave of Gargas, France.1 Possible diagnoses for the deficiencies found in many of the hand pictures, and some non-medical theories of explanation, are reviewed. It is concluded that the hands used as stencils were mutilated and that the images were deliberately placed within the cave and were not the by-products of some other activity. PMID:6990130

  1. Hand fracture - aftercare

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000552.htm Hand fracture - aftercare To use the sharing features on ... need to be repaired with surgery. Types of Hand Fractures Your fracture may be in one of ...

  2. Physical examination of the hand.

    PubMed

    Kenney, Raymond J; Hammert, Warren C

    2014-11-01

    Examination of the hand is an essential piece of a hand surgeon's skill set. This current concepts review presents a systematic process of performing a comprehensive physical examination of the hand including vascular, sensory, and motor assessments. Evaluations focused on specific hand diseases and injuries are also discussed. This information can be useful for any health care provider treating patients with hand conditions. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. Determination of hand soil loading, soil transfer, and particle size variations after hand-pressing and hand-mouthing activities

    EPA Science Inventory

    Hand-pressing trials and hand-to-mouth soil transfer experiments were conducted to better understand soil loadings, soil transfer ratios for three mouthing activities, and variations in particle size distributions under various conditions. Results indicated that sand caused highe...

  4. Coordination of hand shape.

    PubMed

    Pesyna, Colin; Pundi, Krishna; Flanders, Martha

    2011-03-09

    The neural control of hand movement involves coordination of the sensory, motor, and memory systems. Recent studies have documented the motor coordinates for hand shape, but less is known about the corresponding patterns of somatosensory activity. To initiate this line of investigation, the present study characterized the sense of hand shape by evaluating the influence of differences in the amount of grasping or twisting force, and differences in forearm orientation. Human subjects were asked to use the left hand to report the perceived shape of the right hand. In the first experiment, six commonly grasped items were arranged on the table in front of the subject: bottle, doorknob, egg, notebook, carton, and pan. With eyes closed, subjects used the right hand to lightly touch, forcefully support, or imagine holding each object, while 15 joint angles were measured in each hand with a pair of wired gloves. The forces introduced by supporting or twisting did not influence the perceptual report of hand shape, but for most objects, the report was distorted in a consistent manner by differences in forearm orientation. Subjects appeared to adjust the intrinsic joint angles of the left hand, as well as the left wrist posture, so as to maintain the imagined object in its proper spatial orientation. In a second experiment, this result was largely replicated with unfamiliar objects. Thus, somatosensory and motor information appear to be coordinated in an object-based, spatial-coordinate system, sensitive to orientation relative to gravitational forces, but invariant to grasp forcefulness.

  5. Inexpensive and Time-Efficient Hand Hygiene Interventions Increase Elementary School Children's Hand Hygiene Rates

    ERIC Educational Resources Information Center

    Snow, Michelle; White, George L.; Kim, Han S.

    2008-01-01

    Routine hand hygiene has been cited by the World Health Organization and the Centers for Disease Control and Prevention as a cost-effective and important hygiene measure in preventing the spread of infectious diseases. Several studies have explored children's hand hygiene habits, effects of scheduled hand hygiene, hand hygiene environmental…

  6. Two-Thumbed Robot Hand

    NASA Technical Reports Server (NTRS)

    Lee, Sukhan

    1989-01-01

    Robot hand includes thumblike members on left and right sides and fingerlike member at middle. Configuration of digits enables hand to adapt to variously shaped objects, grasp them robustly and reliably, and manipulate them. Reduces complexity of control mechanisms and provides kinesthetic perception of shapes of grasped objects. Mechanical hand with two thumbs and middle finger made from commercially available components. With specially designed dc motors and assemblies of gears, size of hand reduced considerably. Suited to handling objects in industrial tasks.

  7. Fragrance allergy in patients with hand eczema - a clinical study.

    PubMed

    Heydorn, Siri; Johansen, Jeanne Duus; Andersen, Klaus E; Bruze, Magnus; Svedman, Cecilia; White, Ian R; Basketter, David A; Menné, Torkil

    2003-06-01

    Fragrance allergy and hand eczema are both common among dermatological patients. Fragrance mix (FM) and its constituents have a recognized relevance to exposure to fine fragrances and cosmetic products. Based on extensive chemical analysis and database search, a new selection of fragrances was established, including 14 known fragrance allergens present in products to which hand exposure would occur. A non-irritating patch-test concentration for some fragrances was established in 212 consecutive patients. 658 consecutive patients presenting with hand eczema were patch tested with the European standard series and the developed selection of fragrances. 67 (10.2%) of the 658 patients had a positive reaction to 1 or more of our selection of fragrance chemicals present in the new selection. The most common reactions to fragrances not included in the FM were to citral, Lyral (hydroxyisohexyl-3-cyclohexene carboxaldehyde) and oxidized l-limonene. A concomitant reaction to the FM identified potential fragrance allergy in less than (1/2) of these patients. Exposure assessment and a statistically significant association between a positive patch test to our selected fragrances and patients' history support the relevance of this selection of fragrances. Those with a positive reaction to our selected fragrances were significantly more likely to have 1 or more positive patch tests in the standard series. This observation is the basis for the hypothesis concerning cross-reactivity and the effect of simultaneous exposure. The study found that fragrance allergy could be a common problem in patients with eczema on the hands.

  8. Programming of left hand exploits task set but that of right hand depends on recent history.

    PubMed

    Tang, Rixin; Zhu, Hong

    2017-07-01

    There are many differences between the left hand and the right hand. But it is not clear if there is a difference in programming between left hand and right hand when the hands perform the same movement. In current study, we carried out two experiments to investigate whether the programming of two hands was equivalent or they exploited different strategies. In the first experiment, participants were required to use one hand to grasp an object with visual feedback or to point to the center of one object without visual feedback on alternate trials, or to grasp an object without visual feedback and to point the center of one object with visual feedback on alternating trials. They then performed the tasks with the other hand. The result was that previous pointing task affected current grasping when it was performed by the left hand, but not the right hand. In experiment 2, we studied if the programming of the left (or right) hand would be affected by the pointing task performed on the previous trial not only by the same hand, but also by the right (or left) hand. Participants pointed and grasped the objects alternately with two hands. The result was similar with Experiment 1, i.e., left-hand grasping was affected by right-hand pointing, whereas right-hand grasping was immune from the interference from left hand. Taken together, the results suggest that when open- and closed-loop trials are interleaved, motor programming of grasping with the right hand was affected by the nature of the online feedback on the previous trial only if it was a grasping trial, suggesting that the trial-to-trial transfer depends on sensorimotor memory and not on task set. In contrast, motor programming of grasping with the left hand can use information about the nature of the online feedback on the previous trial to specify the parameters of the movement, even when the type of movement that occurred was quite different (i.e., pointing) and was performed with the right hand. This suggests that

  9. Comparison of Standard Culture-Based Method to Culture-Independent Method for Evaluation of Hygiene Effects on the Hand Microbiome.

    PubMed

    Zapka, C; Leff, J; Henley, J; Tittl, J; De Nardo, E; Butler, M; Griggs, R; Fierer, N; Edmonds-Wilson, S

    2017-03-28

    Hands play a critical role in the transmission of microbiota on one's own body, between individuals, and on environmental surfaces. Effectively measuring the composition of the hand microbiome is important to hand hygiene science, which has implications for human health. Hand hygiene products are evaluated using standard culture-based methods, but standard test methods for culture-independent microbiome characterization are lacking. We sampled the hands of 50 participants using swab-based and glove-based methods prior to and following four hand hygiene treatments (using a nonantimicrobial hand wash, alcohol-based hand sanitizer [ABHS], a 70% ethanol solution, or tap water). We compared results among culture plate counts, 16S rRNA gene sequencing of DNA extracted directly from hands, and sequencing of DNA extracted from culture plates. Glove-based sampling yielded higher numbers of unique operational taxonomic units (OTUs) but had less diversity in bacterial community composition than swab-based sampling. We detected treatment-induced changes in diversity only by using swab-based samples ( P < 0.001); we were unable to detect changes with glove-based samples. Bacterial cell counts significantly decreased with use of the ABHS ( P < 0.05) and ethanol control ( P < 0.05). Skin hydration at baseline correlated with bacterial abundances, bacterial community composition, pH, and redness across subjects. The importance of the method choice was substantial. These findings are important to ensure improvement of hand hygiene industry methods and for future hand microbiome studies. On the basis of our results and previously published studies, we propose recommendations for best practices in hand microbiome research. IMPORTANCE The hand microbiome is a critical area of research for diverse fields, such as public health and forensics. The suitability of culture-independent methods for assessing effects of hygiene products on microbiota has not been demonstrated. This is the

  10. iHand: an interactive bare-hand-based augmented reality interface on commercial mobile phones

    NASA Astrophysics Data System (ADS)

    Choi, Junyeong; Park, Jungsik; Park, Hanhoon; Park, Jong-Il

    2013-02-01

    The performance of mobile phones has rapidly improved, and they are emerging as a powerful platform. In many vision-based applications, human hands play a key role in natural interaction. However, relatively little attention has been paid to the interaction between human hands and the mobile phone. Thus, we propose a vision- and hand gesture-based interface in which the user holds a mobile phone in one hand but sees the other hand's palm through a built-in camera. The virtual contents are faithfully rendered on the user's palm through palm pose estimation, and reaction with hand and finger movements is achieved that is recognized by hand shape recognition. Since the proposed interface is based on hand gestures familiar to humans and does not require any additional sensors or markers, the user can freely interact with virtual contents anytime and anywhere without any training. We demonstrate that the proposed interface works at over 15 fps on a commercial mobile phone with a 1.2-GHz dual core processor and 1 GB RAM.

  11. Antimicrobial efficacy of soap and water hand washing versus an alcohol-based hand cleanser.

    PubMed

    Holton, Ronald H; Huber, Michaell A; Terezhalmy, Geza T

    2009-12-01

    The emergence of alcohol-based hand cleansers may represent an alternative to soap and water in the clinical dental setting. In this study, the antimicrobial efficacy of traditional hand washing vs. a unique alcohol-based hand cleanser with persistence was evaluated. Two experienced dentists participated over a 10-day period. On days 1-5, each clinician used an antibacterial liquid soap (Dial, Dial Corporation, Scottsdale, AZ). Days 6-10, an alcohol-based hand cleanser (Triseptin Water Optional, Healthpoint Surgical, Fort Worth, TX) was used. Sampling was by modified glove juice technique. The results indicate that the alcohol-based hand cleanser dramatically outperforms the traditional hand washing agent in the general dental setting.

  12. Unimanual SNARC Effect: Hand Matters.

    PubMed

    Riello, Marianna; Rusconi, Elena

    2011-01-01

    A structural representation of the hand embedding information about the identity and relative position of fingers is necessary to counting routines. It may also support associations between numbers and allocentric spatial codes that predictably interact with other known numerical spatial representations, such as the mental number line (MNL). In this study, 48 Western participants whose typical counting routine proceeded from thumb-to-little on both hands performed magnitude and parity binary judgments. Response keys were pressed either with the right index and middle fingers or with the left index and middle fingers in separate blocks. 24 participants responded with either hands in prone posture (i.e., palm down) and 24 participants responded with either hands in supine (i.e., palm up) posture. When hands were in prone posture, the counting direction of the left hand conflicted with the direction of the left-right MNL, whereas the counting direction of the right hand was consistent with it. When hands were in supine posture, the opposite was true. If systematic associations existed between relative number magnitude and an allocentric spatial representation of the finger series within each hand, as predicted on the basis of counting habits, interactions would be expected between hand posture and a unimanual version of the spatial-numerical association of response codes (SNARC) effect. Data revealed that with hands in prone posture a unimanual SNARC effect was present for the right hand, and with hands in supine posture a unimanual SNARC effect was present for the left hand. We propose that a posture-invariant body structural representation of the finger series provides a relevant frame of reference, a within-hand directional vector, that is associated to simple number processing. Such frame of reference can significantly interact with stimulus-response correspondence effects, like the SNARC, that have been typically attributed to the mapping of numbers on a left

  13. Hand osteoarthritis: an epidemiological perspective.

    PubMed

    Kalichman, Leonid; Hernández-Molina, Gabriela

    2010-06-01

    Hand osteoarthritis (OA) is a highly prevalent condition with a wide spectrum of clinical presentations. We review herein the prevalence, impact on hand function, and various risk factors related to hand OA. PubMed and MEDLINE databases (1950-2009) were searched for the keywords: "hand," "hand osteoarthritis," "distal interphalangeal," "proximal interphalangeal," "metacarpophalangeal," and "carpometacarpal." Published material emphasizing cohort, cross-sectional, and case-control studies regarding epidemiology, clinical features, functional impairment, and associated risk factors of hand OA were included. Hand OA is a heterogeneous, age- and gender-dependent disorder, occurring more frequently in women over 50 years of age. In the elderly population, the prevalence of radiographic hand OA can reach 80%. OA has a strong genetic predisposition, apparently gender- and phenotype-specific. A history of heavy manual labor or a repetitive use of the hand also has been linked to OA. Other variables such as weight, smoking, joint hyperlaxity, age of menarche, bone and cartilage mineralization factors, grip strength, and handedness may play a role. Symptomatic hand OA may cause functional impairment due to loss of strength, thus limiting the individual's ability to perform daily tasks. Several risk factors for hand OA have been identified; however, their interrelationship is not clearly understood. The development of preventive strategies and future research goals is needed. Copyright 2010 Elsevier Inc. All rights reserved.

  14. Hand-transmitted vibration and biodynamic response of the human hand-arm: a critical review.

    PubMed

    Dong, R G; Rakheja, S; Schopper, A W; Han, B; Smutz, W P

    2001-01-01

    Hand-arm vibration syndrome (HAVS) has been associated with prolonged exposure to vibration transmitted to the human hand-arm system from hand-held power tools, vibrating machines, or hand-held vibrating workpieces. The biodynamic response of the human hand and arm to hand transmitted vibration (HTV) forms an essential basis for effective evaluations of exposures, vibration-attenuation mechanisms, and potential injury mechanisms. The biodynamic response to HTV and its relationship to HAVS are critically reviewed and discussed to highlight the advances and the need for further research. In view of its strong dependence on the nature of HTV and the lack of general agreement on the characteristics of HTV, the reported studies are first reviewed to enhance an understanding of HTV and related issues. The characteristics of HTV and relevant unresolved issues are discussed on the basis of measured data, proposed standards, and measurement methods, while the need for further developments in measurement systems is emphasized. The studies on biodynamic response and their findings are grouped into four categories based on the methodology used and the objective. These include studies on (1) through-the-hand-arm response, expressed in terms of vibration transmissibility; (2) to-the-hand response, expressed in terms of the force-motion relationship of the hand-arm system; (3) to-the-hand biodynamic response function, expressed in terms of vibration energy absorption; and (4) computer modeling of the biodynamic response characteristics.

  15. Patterns of behavior across reproductive states of free-ranging female black-handed spider monkeys (Ateles geoffroyi).

    PubMed

    Campbell, Christina J

    2004-06-01

    Reports on the behavior of spider monkeys (genus Ateles) describe a suite of 5-6 behaviors that are indicative of an estrous female. This study presents hormonal data as an independent measure of reproductive state to determine if these behaviors are associated with any particular reproductive state or stage of the ovarian cycle. Fecal samples collected from 6 free-ranging female black-handed spider monkeys (Ateles geoffroyi) over the course of 11 months were assayed for estrogen (E1C) and progesterone (PdG) metabolites, using an enzyme immunoassay. Behavioral data collected from the same females were analyzed for patterns associated with different reproductive states. A more detailed analysis of behavioral data associated with reproductively cycling periods determined whether each behavior clustered with copulations or a particular phase in the ovarian cycle. Observations of place-sniffing were more frequent for 4 of 5 females when reproductively cycling. Of all copulations observed, 80% occurred when the female participant was reproductively cycling. In addition, the rates of self-clitoral hold and self-clitoral rub behaviors were significantly higher for 2 of 4 and 4 of 5 of females, respectively, when reproductively cycling. No behavior consistently occurred in association with copulations or with any particular phase in the ovarian cycle. Results from this study suggest that the behaviors tested in this paper can provide some information regarding female spider monkey reproductive state (whether or not she is reproductively cycling), but that they are not indicators of estrus in female spider monkeys. Copyright 2003 Wiley-Liss, Inc.

  16. Co-speech hand movements during narrations: What is the impact of right vs. left hemisphere brain damage?

    PubMed

    Hogrefe, Katharina; Rein, Robert; Skomroch, Harald; Lausberg, Hedda

    2016-12-01

    Persons with brain damage show deviant patterns of co-speech hand movement behaviour in comparison to healthy speakers. It has been claimed by several authors that gesture and speech rely on a single production mechanism that depends on the same neurological substrate while others claim that both modalities are closely related but separate production channels. Thus, findings so far are contradictory and there is a lack of studies that systematically analyse the full range of hand movements that accompany speech in the condition of brain damage. In the present study, we aimed to fill this gap by comparing hand movement behaviour in persons with unilateral brain damage to the left and the right hemisphere and a matched control group of healthy persons. For hand movement coding, we applied Module I of NEUROGES, an objective and reliable analysis system that enables to analyse the full repertoire of hand movements independent of speech, which makes it specifically suited for the examination of persons with aphasia. The main results of our study show a decreased use of communicative conceptual gestures in persons with damage to the right hemisphere and an increased use of these gestures in persons with left brain damage and aphasia. These results not only suggest that the production of gesture and speech do not rely on the same neurological substrate but also underline the important role of right hemisphere functioning for gesture production. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Hierarchy of evidence relating to hand surgery in Brazilian orthopedic journals.

    PubMed

    Moraes, Vinícius Ynoe de; Belloti, João Carlos; Moraes, Fábio Ynoe de; Galbiatti, José Antonio; Palácio, Evandro Pereira; Santos, João Baptista Gomes Dos; Faloppa, Flávio

    2011-03-01

    There is no systematic assessment of the quality of scientific production in the specialty of hand surgery in our setting. This study aimed to systematically assess the status of evidence generation relating to hand surgery and to evaluate the reproducibility of the classification method based on an evidence pyramid. Secondary study conducted at Universidade Federal de São Paulo (Unifesp) and Faculdade Estadual de Medicina de Marília (Famema). Two researchers independently conducted an electronic database search for hand surgery studies published between 2000 and 2009 in the two main Brazilian orthopedic journals (Acta Ortopédica Brasileira and Revista Brasileira de Ortopedia). The studies identified were subsequently classified according to methodological design (systematic review of the literature, randomized clinical trial, cohort study, case-control study, case series and other studies) and evidence level (I to V). A total of 1,150 articles were evaluated, and 83 (7.2%) were included in the final analysis. Studies with evidence level IV (case series) accounted for 41 (49%) of the published papers. Studies with evidence level V (other studies) accounted for 12 (14.5%) of the papers. Only two studies (2.4%) were ranked as level I or II. The inter-rater reproducibility was excellent (k = 0.94). Hand surgery articles corresponded to less than one tenth of Brazilian orthopedic production. Studies with evidence level IV were the commonest type. The reproducibility of the classification stratified by evidence level was almost perfect.

  18. Replicating Human Hand Synergies Onto Robotic Hands: A Review on Software and Hardware Strategies.

    PubMed

    Salvietti, Gionata

    2018-01-01

    This review reports the principal solutions proposed in the literature to reduce the complexity of the control and of the design of robotic hands taking inspiration from the organization of the human brain. Several studies in neuroscience concerning the sensorimotor organization of the human hand proved that, despite the complexity of the hand, a few parameters can describe most of the variance in the patterns of configurations and movements. In other words, humans exploit a reduced set of parameters, known in the literature as synergies, to control their hands. In robotics, this dimensionality reduction can be achieved by coupling some of the degrees of freedom (DoFs) of the robotic hand, that results in a reduction of the needed inputs. Such coupling can be obtained at the software level, exploiting mapping algorithm to reproduce human hand organization, and at the hardware level, through either rigid or compliant physical couplings between the joints of the robotic hand. This paper reviews the main solutions proposed for both the approaches.

  19. A Helping Hand.

    ERIC Educational Resources Information Center

    Renner, Jason M.

    2000-01-01

    Discusses how designing a hand washing-friendly environment can help to reduce the spread of germs in school restrooms. Use of electronic faucets, surface risk management, traffic flow, and user- friendly hand washing systems that are convenient and maximally hygienic are examined. (GR)

  20. [Hand transplantation and implantation of nerve chips. New developments within hand surgery].

    PubMed

    Dahlin, L; Fridén, J; Hagberg, L; Lundborg, G

    1999-10-06

    Injuries and diseases of the hand naturally have an enormous impact on hand function and on quality of life, both occupational and social. The majority of hand-injury patients are under 30 years of age. Hand surgery, an established specialty in Sweden since 1969, is of great importance in terms of clinical developments, education and research. In the coming decade, scientific and clinical advances are to be expected in several fields such as nerve injuries including brachial plexus lesion, microsurgery, flexor tendon injuries and tendon transfer. Bioimplant research and new advances at the biotechnological interface will yield new options in nerve reconstruction, microchip implants in the nervous system, and the restoration of muscle-tendon function following injury. Artificial limbs with advanced motor and sensory functions will be important future aids in the rehabilitation of amputees. Transplantation of human hands is another promising reconstructive procedure which may open up new perspectives in the coming millennium.

  1. [Hand transplantation and implantation of nerve chips. New developments within hand surgery].

    PubMed

    Dahlin, L; Fridén, J; Hagberg, L; Lundborg, G

    2000-03-20

    Injuries and diseases of the hand naturally have an enormous impact on hand function and on quality of life, both occupational and social. The majority of hand-injury patients are under 30 years of age. Hand surgery, an established specialty in Sweden since 1969, is of great importance in terms of clinical developments, education and research. In the coming decade, scientific and clinical advances are to be expected in several fields such as nerve injuries including brachial plexus lesion, microsurgery, flexor tendon injuries and tendon transfer. Bioimplant research and new advances at the biotechnological interface will yield new options in nerve reconstruction, microchip implants in the nervous system, and the restoration of muscle-tendon function following injury. Artificial limbs with advanced motor and sensory functions will be important future aids in the rehabilitation of amputees. Transplantation of human hands is another promising reconstructive procedure which may open iup new perspectives in the coming millennium.

  2. P/2013 P5 PANSTARRS --- a rubbing binary?

    NASA Astrophysics Data System (ADS)

    Hainaut, O.; Snodgrass, C.

    2014-07-01

    disruption is a possible interpretation [15-17]: the peaks of activity would represent the effects of centrifugal landslides and surface readjustments. We propose another process [17]: we suggest that P5 is a small, quasi-contact binary, whose components are either occasionally touching, or settling together into a full-contact binary. The object would then release dust liberated by these repeated low velocity impact, or rather rubbing between its components. Sharma [19] studied the equilibrium of rubble-pile binaries, and concluded that many stable solutions exist for contact and near-contact objects, with a range of prolateness for both components and for a range of shear resistance of the rubble pile. In other words, such an object, if it can be formed, can be stable. Descamp [20] reviewed observations of known binaries in the context of the Roche systems, i.e. fully synchronized binary objects in fluid equilibrium. Several objects appear to be contact binaries, including some very small objects in the same size range as P5, e.g., 2002 NY_40 and 2005 CR_37. Radar observations [21] showed that (69230) Hermes is a fully synchronized binary, with components only slightly larger than P5 (630 and 560 m), separated by a few radii (1200 m). While their formation process is not known, these observations suggest that small, fully synchronized contact binaries do exist. In the case of P5, this hypothesis can be tested observationally, as the 3^{rd} Kepler law indicates that the rotation period of the system should be of several hours, while a rotationally disrupted object should have a period of around 2 h or less. In the mean time, this idea is submitted to ACM.

  3. Grasping with the eyes of your hands: hapsis and vision modulate hand preference.

    PubMed

    Stone, Kayla D; Gonzalez, Claudia L R

    2014-02-01

    Right-hand preference has been demonstrated for visually guided reaching and grasping. Grasping, however, requires the integration of both visual and haptic cues. To what extent does vision influence hand preference for grasping? Is there a hand preference for haptically guided grasping? Two experiments were designed to address these questions. In Experiment 1, individuals were tested in a reaching-to-grasp task with vision (sighted condition) and with hapsis (blindfolded condition). Participants were asked to put together 3D models using building blocks scattered on a tabletop. The models were simple, composed of ten blocks of three different shapes. Starting condition (Vision-First or Hapsis-First) was counterbalanced among participants. Right-hand preference was greater in visually guided grasping but only in the Vision-First group. Participants who initially built the models while blindfolded (Hapsis-First group) used their right hand significantly less for the visually guided portion of the task. To investigate whether grasping using hapsis modifies subsequent hand preference, participants received an additional haptic experience in a follow-up experiment. While blindfolded, participants manipulated the blocks in a container for 5 min prior to the task. This additional experience did not affect right-hand use on visually guided grasping but had a robust effect on haptically guided grasping. Together, the results demonstrate first that hand preference for grasping is influenced by both vision and hapsis, and second, they highlight how flexible this preference could be when modulated by hapsis.

  4. The Geriatric Hand: Correlation of Hand-Muscle Function and Activity Restriction in Elderly

    ERIC Educational Resources Information Center

    Incel, Nurgul Arinci; Sezgin, Melek; As, Ismet; Cimen, Ozlem Bolgen; Sahin, Gunsah

    2009-01-01

    On the basis of the importance of hand manipulation in activities of daily living (ADL), deterioration of hand function because of various factors reduces quality and independence of life of the geriatric population. The aim of this study was to identify age-induced changes in manual function and to quantify the correlations between hand-muscle…

  5. Verbal Prompting, Hand-over-Hand Instruction, and Passive Observation in Teaching Children with Developmental Disabilities.

    ERIC Educational Resources Information Center

    Biederman, G. B.; Fairhall, J. L.; Raven, K. A.; Davey, V. A.

    1998-01-01

    A study involving six children (ages 5-13) with mental retardation found that overall passive modeling was significantly more effective than hand-over-hand modeling in teaching skills, and that passive modeling was significantly more effective than hand-over-hand modeling with response-contingent verbal prompting. (Author/CR)

  6. Hand controller commonality evaluation process

    NASA Technical Reports Server (NTRS)

    Stuart, Mark A.; Bierschwale, John M.; Wilmington, Robert P.; Adam, Susan C.; Diaz, Manuel F.; Jensen, Dean G.

    1993-01-01

    Hand controller selection for NASA's Orbiter and Space Station Freedom is an important area of human-telerobot interface design and evaluation. These input devices will control remotely operated systems that include large crane-like manipulators (e.g., Remote Manipulator System or RMS), smaller, more dexterous manipulators (e.g., Flight Telerobotic Servicer or FTS), and free flyers (e.g., Orbital Maneuvering Vehicle or OMV). Candidate hand controller configurations for these systems vary in many ways: shape, size, number of degrees-of-freedom (DOF), operating modes, provision of force reflection, range of movement, and 'naturalness' of use. Unresolved design implementation issues remain, including such topics as how the current Orbiter RMS rotational and translational rate hand controllers compare with the proposed Space Station Freedom hand controllers, the advantages that position hand controllers offer for these applications, and whether separate hand controller configurations are required for each application. Since previous studies contain little empirical hand controller task performance data, a controlled study is needed that tests Space Station Freedom candidate hand controllers during representative tasks. This study also needs to include anthropometric and biomechanical considerations.

  7. Individual left-hand and right-hand intra-digit representations in human primary somatosensory cortex.

    PubMed

    Schweisfurth, Meike A; Frahm, Jens; Schweizer, Renate

    2015-09-01

    Individual intra-digit somatotopy of all phalanges of the middle and little finger of the right and left hand was studied by functional magnetic resonance imaging in 12 healthy subjects. Phalanges were tactilely stimulated and activation in BA 3b of the human primary somatosensory cortex could be observed for each individual phalanx. Activation peaks were further analysed using the Direction/Order (DiOr) method, which identifies somatotopy, if a significantly high number of subjects exhibit ordered distal-to-proximal phalanx representions along a similar direction. Based on DiOr, ordered and similar-direction-aligned intra-digit maps across subjects were found at the left hand for the little and middle finger and at the right hand for the little finger. In these digits the proximal phalanges were represented more medially along the course of the central sulcus than the distal phalanges. This is contrasted by the intra-digit maps for the middle finger of the right hand, which showed larger inter-subject variations of phalanx alignments without a similar within-digit representation across subjects. As all subjects were right-handed and as the middle finger of the dominant hand probably plays a more individual role in everyday tactile performance than the little finger of the right hand and all left-hand digits, the observed variation might reflect a functional somatotopy based on individual use of that particular digit at the dominant hand. © 2015 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  8. Hand posture and cognitive control: The congruency sequence effect is reduced near the hands.

    PubMed

    Englert, Julia; Wentura, Dirk

    2016-10-01

    According to several recent articles, attentional processing seems to be modulated by the proximity of one's own hand to a stimulus. Weidler and Abrams (Psychonomic Bulletin & Review, 21, 462-469, 2014) found a significant reduction of the Eriksen flanker effect when the stimuli were presented close to the participants' hands. They interpreted this as evidence for stronger cognitive control near the hands. Using a near-by hands manipulation intended to vary distance while keeping posture of the hands constant, we found a modulation of the congruency sequence effect (CSE or Gratton effect), i.e., a larger flanker effect following incompatible trials than following compatible trials. The CSE was eliminated near the hands. Though we did not find a reduction in the flanker effect itself (which might be the result of using a near-by hand manipulation somewhat different from that of Weidler and Abrams), this result can be considered to be compatible with Weidler and Abrams' original hypothesis if the congruency sequence effect is interpreted in terms of cognitive control.

  9. Dissociable neural responses to hands and non-hand body parts in human left extrastriate visual cortex.

    PubMed

    Bracci, Stefania; Ietswaart, Magdalena; Peelen, Marius V; Cavina-Pratesi, Cristiana

    2010-06-01

    Accumulating evidence points to a map of visual regions encoding specific categories of objects. For example, a region in the human extrastriate visual cortex, the extrastriate body area (EBA), has been implicated in the visual processing of bodies and body parts. Although in the monkey, neurons selective for hands have been reported, in humans it is unclear whether areas selective for individual body parts such as the hand exist. Here, we conducted two functional MRI experiments to test for hand-preferring responses in the human extrastriate visual cortex. We found evidence for a hand-preferring region in left lateral occipitotemporal cortex in all 14 participants. This region, located in the lateral occipital sulcus, partially overlapped with left EBA, but could be functionally and anatomically dissociated from it. In experiment 2, we further investigated the functional profile of hand- and body-preferring regions by measuring responses to hands, fingers, feet, assorted body parts (arms, legs, torsos), and non-biological handlike stimuli such as robotic hands. The hand-preferring region responded most strongly to hands, followed by robotic hands, fingers, and feet, whereas its response to assorted body parts did not significantly differ from baseline. By contrast, EBA responded most strongly to body parts, followed by hands and feet, and did not significantly respond to robotic hands or fingers. Together, these results provide evidence for a representation of the hand in extrastriate visual cortex that is distinct from the representation of other body parts.

  10. Dissociable Neural Responses to Hands and Non-Hand Body Parts in Human Left Extrastriate Visual Cortex

    PubMed Central

    Ietswaart, Magdalena; Peelen, Marius V.; Cavina-Pratesi, Cristiana

    2010-01-01

    Accumulating evidence points to a map of visual regions encoding specific categories of objects. For example, a region in the human extrastriate visual cortex, the extrastriate body area (EBA), has been implicated in the visual processing of bodies and body parts. Although in the monkey, neurons selective for hands have been reported, in humans it is unclear whether areas selective for individual body parts such as the hand exist. Here, we conducted two functional MRI experiments to test for hand-preferring responses in the human extrastriate visual cortex. We found evidence for a hand-preferring region in left lateral occipitotemporal cortex in all 14 participants. This region, located in the lateral occipital sulcus, partially overlapped with left EBA, but could be functionally and anatomically dissociated from it. In experiment 2, we further investigated the functional profile of hand- and body-preferring regions by measuring responses to hands, fingers, feet, assorted body parts (arms, legs, torsos), and non-biological handlike stimuli such as robotic hands. The hand-preferring region responded most strongly to hands, followed by robotic hands, fingers, and feet, whereas its response to assorted body parts did not significantly differ from baseline. By contrast, EBA responded most strongly to body parts, followed by hands and feet, and did not significantly respond to robotic hands or fingers. Together, these results provide evidence for a representation of the hand in extrastriate visual cortex that is distinct from the representation of other body parts. PMID:20393066

  11. Hand assessment in older adults with musculoskeletal hand problems: a reliability study.

    PubMed

    Myers, Helen L; Thomas, Elaine; Hay, Elaine M; Dziedzic, Krysia S

    2011-01-07

    Musculoskeletal hand pain is common in the general population. This study aims to investigate the inter- and intra-observer reliability of two trained observers conducting a simple clinical interview and physical examination for hand problems in older adults. The reliability of applying the American College of Rheumatology (ACR) criteria for hand osteoarthritis to community-dwelling older adults will also be investigated. Fifty-five participants aged 50 years and over with a current self-reported hand problem and registered with one general practice were recruited from a previous health questionnaire study. Participants underwent a standardised, structured clinical interview and physical examination by two independent trained observers and again by one of these observers a month later. Agreement beyond chance was summarised using Kappa statistics and intra-class correlation coefficients. Median values for inter- and intra-observer reliability for clinical interview questions were found to be "substantial" and "moderate" respectively [median agreement beyond chance (Kappa) was 0.75 (range: -0.03, 0.93) for inter-observer ratings and 0.57 (range: -0.02, 1.00) for intra-observer ratings]. Inter- and intra-observer reliability for physical examination items was variable, with good reliability observed for some items, such as grip and pinch strength, and poor reliability observed for others, notably assessment of altered sensation, pain on resisted movement and judgements based on observation and palpation of individual features at single joints, such as bony enlargement, nodes and swelling. Moderate agreement was observed both between and within observers when applying the ACR criteria for hand osteoarthritis. Standardised, structured clinical interview is reliable for taking a history in community-dwelling older adults with self reported hand problems. Agreement between and within observers for physical examination items is variable. Low Kappa values may have resulted

  12. [Complex trauma of the hand].

    PubMed

    Pechlaner, S; Hussl, H

    1998-01-01

    The hand is very exposed to injuries in the daily man's work. The multiple functions of the hand are based on vitality, sensibility, motor function and stability. In severe hand injuries the functional results of the repair are often very poor. In a complex injury of the hand we are faced with the damage of the soft tissue and bone and the loss of vitality and function of the hand. The cause of hand injuries are mainly a crush trauma or the rotating saw. Basically, we recommend an extended primary repair. After the radical debridement we have to reconstruct the damaged structures. We start doing the osteosynthesis and stabilization of the joints. Thereafter, suturing of extensor and flexor tendons. Then, we do the microsurgical reconstructions of vessels and nerves. In case tendons and bones are exposed we have to cover the defect with a pedicled or a free flap. In a long ischemic time we have to change our concept and do the reconstruction of the vessels first. Our results in vitality and sensibility are listed. In the result of a complex hand injury each single functional restoration is very important. Therefore, it is necessary that severe hand injuries are treated at well established centres for hand surgery.

  13. A qualitative analysis of the experience and impact of killing in hand-to-hand combat.

    PubMed

    Jensen, Peter R; Simpson, Duncan

    2014-08-01

    A growing body of research suggests that killing during military combat is closely associated with posttraumatic stress disorder (PTSD), as well as a number of other adverse mental health related conditions (e.g., dissociative experiences, violent behavior, functional impairment). This article provides first-person perspectives on the experiences and impact of killing by service members with the goal of expanding our understanding of the impact of taking a life during war. In audio-recorded phenomenological interviews, 9 service members described their experiences and the subsequent impact of killing during hand-to-hand combat. A description, supported by participant quotations, was constructed to represent the participants' experiences. Results suggest the experience and aftermath of taking a life in hand-to-hand combat was disturbing, psychologically stressful, and necessitated some form of coping after the event. Service members who killed in hand-to-hand combat viewed their actions as necessary to preserve their life and that killing in hand-to-hand combat was more emotionally taxing than killing by shooting. Our findings may help to improve providers' understanding of service members' first-person experiences of killing in hand-to-hand combat and thus provide the basis for the development of a connected and genuine relationship with such military clients. Copyright © 2014 International Society for Traumatic Stress Studies.

  14. Access to waterless hand sanitizer improves student hand hygiene behavior in primary schools in Nairobi, Kenya.

    PubMed

    Pickering, Amy J; Davis, Jennifer; Blum, Annalise G; Scalmanini, Jenna; Oyier, Beryl; Okoth, George; Breiman, Robert F; Ram, Pavani K

    2013-09-01

    Handwashing is difficult in settings with limited resources and water access. In primary schools within urban Kibera, Kenya, we investigated the impact of providing waterless hand sanitizer on student hand hygiene behavior. Two schools received a waterless hand sanitizer intervention, two schools received a handwashing with soap intervention, and two schools received no intervention. Hand cleaning behavior after toilet use was monitored for 2 months using structured observation. Hand cleaning after toileting was 82% at sanitizer schools (N = 2,507 toileting events), 38% at soap schools (N = 3,429), and 37% at control schools (N = 2,797). Students at sanitizer schools were 23% less likely to have observed rhinorrhea than control students (P = 0.02); reductions in student-reported gastrointestinal and respiratory illness symptoms were not statistically significant. Providing waterless hand sanitizer markedly increased student hand cleaning after toilet use, whereas the soap intervention did not. Waterless hand sanitizer may be a promising option to improve student hand cleansing behavior, particularly in schools with limited water access.

  15. Robotic hand and fingers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salisbury, Curt Michael; Dullea, Kevin J.

    Technologies pertaining to a robotic hand are described herein. The robotic hand includes one or more fingers releasably attached to a robotic hand frame. The fingers can abduct and adduct as well as flex and tense. The fingers are releasably attached to the frame by magnets that allow for the fingers to detach from the frame when excess force is applied to the fingers.

  16. The left hand doesn't know what the right hand is doing: the disruptive effects of attention to the hands in skilled typewriting.

    PubMed

    Logan, Gordon D; Crump, Matthew J C

    2009-10-01

    Everyone knows that attention to the details disrupts skilled performance, but little empirical evidence documents this fact. We show that attention to the hands disrupts skilled typewriting. We had skilled typists type words preceded by cues that told them to type only the letters assigned to one hand or to type all of the letters. Cuing the hands disrupted performance markedly, slowing typing and increasing the error rate (Experiment 1); these deleterious effects were observed even when no keystrokes were actually inhibited (Experiment 3). However, cuing the same letters with colors was not disruptive (Experiment 2). We account for the disruption with a hierarchical control model, in which an inner loop controls the hands and an outer loop controls what is typed. Typing letters using only one hand requires the outer loop to monitor the inner loop's output; the outer loop slows inner-loop cycle time to increase the likelihood of inhibiting responses with the unwanted hand. This produces the disruption.

  17. Evidence of common and separate eye and hand accumulators underlying flexible eye-hand coordination

    PubMed Central

    Jana, Sumitash; Gopal, Atul

    2016-01-01

    Eye and hand movements are initiated by anatomically separate regions in the brain, and yet these movements can be flexibly coupled and decoupled, depending on the need. The computational architecture that enables this flexible coupling of independent effectors is not understood. Here, we studied the computational architecture that enables flexible eye-hand coordination using a drift diffusion framework, which predicts that the variability of the reaction time (RT) distribution scales with its mean. We show that a common stochastic accumulator to threshold, followed by a noisy effector-dependent delay, explains eye-hand RT distributions and their correlation in a visual search task that required decision-making, while an interactive eye and hand accumulator model did not. In contrast, in an eye-hand dual task, an interactive model better predicted the observed correlations and RT distributions than a common accumulator model. Notably, these two models could only be distinguished on the basis of the variability and not the means of the predicted RT distributions. Additionally, signatures of separate initiation signals were also observed in a small fraction of trials in the visual search task, implying that these distinct computational architectures were not a manifestation of the task design per se. Taken together, our results suggest two unique computational architectures for eye-hand coordination, with task context biasing the brain toward instantiating one of the two architectures. NEW & NOTEWORTHY Previous studies on eye-hand coordination have considered mainly the means of eye and hand reaction time (RT) distributions. Here, we leverage the approximately linear relationship between the mean and standard deviation of RT distributions, as predicted by the drift-diffusion model, to propose the existence of two distinct computational architectures underlying coordinated eye-hand movements. These architectures, for the first time, provide a computational basis for

  18. Improving hand hygiene compliance in healthcare settings using behavior change theories: reflections.

    PubMed

    Al-Tawfiq, Jaffar A; Pittet, Didier

    2013-01-01

    Although hand hygiene is the most effective method for preventing healthcare-associated infections, hand hygiene practice falls short in many healthcare facilities. The compliance rate is mostly linked to system design and easily accessible hand hygiene products. System change, healthcare worker motivation, and complex behavioral considerations seem to play a significant role. This article discusses the application of behavioral theories in hand hygiene promotion in a theoretical manner. The program relies on the transtheoretical model (TTM) of health behavior change, John Keller's (ARCS) Model of Motivational Design, and the theory of planned behavior (TPB). Thus, the program links attitudes and behavior to hand hygiene promotion. The TTM of health behavior change helps to tailor interventions to predict and motivate individual movement across the pathway to change. A program could be based on this theory with multiple intercalations with John Keller's ARCS and the TPB. Such a program could be strengthened by linking attitudes and behavior to promote hand hygiene. The program could utilize different strategies such as organization cultural change that may increase the attention as well as fostering the movement in the ARCS stages. In addition, modeling TPB by creating peer pressure, ability to overcome obstacles, and increasing knowledge of the role of hand hygiene may lead to the desired outcome. The understanding and application of behavior change theories may result in an effective program to improve awareness and raise intention and thus may increase the potential for success of hand hygiene promotion programs.

  19. [Microbiological characteristics of selected liquid soaps for hands washing].

    PubMed

    Tyski, Stefan; Bocian, Ewa; Zawistowska, Anna; Mrówka, Agnieszka; Kruszewska, Hanna; Grzybowska, Wanda; Zareba, Tomasz

    2013-01-01

    According to common belief, supported by the authority of the World Health Organization - WHO, the common (social) hand washing is the simplest, cheapest and the most effective way of reduction the hospital-acquired infections. For this purpose products of"liquid soaps", present in a large number on the market, are most often applied. Microbiological status (microbiological purity and antimicrobial activity) of"liquid soaps" available on the Polish market is not known, because relevant routinely studies have not been performed. Only the antibacterial and / or antifungal activity of certain formulations is sometimes assessed, especially when the manufacturer suggests the standardized application of the products for surgical or hygienic procedures. The aim of this study was to determine the microbiological quality, especially microbiological purity and antimicrobial activity of the selected hands washing products, presents on the Polish market. The 12 selected commercial products, available on the market in Poland, dedicated for hands washing were included into study. Microbiological purity test was carried out in accordance with the Polish Pharmacopoeia (FP) monograph (FP monograph numbers correspond to numbers of the European Pharmacopoeia monograph- Ph. Eur.) No 2.6.12 "Microbiological examination of non-sterile products: microbial enumaration tests", and the monograph of FP No. 2.6.13 "Microbiological examination of non-sterile products: test for specified microorganisms". The following physico-chemical properties of soaps were examined: the pH of the formulations was measured according to the monograph FP No. 2.2.3. "Potentiometric determination of pH", the density of products was assayed according to the monograph FPNo. 2.2.5. "Relative density" and determination the water activity was performed by monograph FP No 2.9.39 "Water-solid interactions: determination of sorption-desorption isotherms and of water activity". Next, antibacterial and antifungal

  20. Reduced asymmetry in motor skill learning in left-handed compared to right-handed individuals.

    PubMed

    McGrath, Robert L; Kantak, Shailesh S

    2016-02-01

    Hemispheric specialization for motor control influences how individuals perform and adapt to goal-directed movements. In contrast to adaptation, motor skill learning involves a process wherein one learns to synthesize novel movement capabilities in absence of perturbation such that they are performed with greater accuracy, consistency and efficiency. Here, we investigated manual asymmetry in acquisition and retention of a complex motor skill that requires speed and accuracy for optimal performance in right-handed and left-handed individuals. We further determined if degree of handedness influences motor skill learning. Ten right-handed (RH) and 10 left-handed (LH) adults practiced two distinct motor skills with their dominant or nondominant arms during separate sessions two-four weeks apart. Learning was quantified by changes in the speed-accuracy tradeoff function measured at baseline and one-day retention. Manual asymmetry was evident in the RH group but not the LH group. RH group demonstrated significantly greater skill improvement for their dominant-right hand than their nondominant-left hand. In contrast, for the LH group, both dominant and nondominant hands demonstrated comparable learning. Less strongly-LH individuals (lower EHI scores) exhibited more learning of their dominant hand. These results suggest that while hemispheric specialization influences motor skill learning, these effects may be influenced by handedness. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Assessing the manipulative potentials of monkeys, apes and humans from hand proportions: implications for hand evolution.

    PubMed

    Liu, Ming-Jin; Xiong, Cai-Hua; Hu, Di

    2016-11-30

    The hand structure possesses a greater potential for performing manipulative skills than is typically observed, whether in humans or non-human anthropoids. However, a precise assessment of the potential manipulative skills of hands has been challenging, which hampers our understanding of the evolution of manipulative abilities in anthropoid hands. Here, we establish a functional model to quantitatively infer the manipulative potentials of anthropoid hands based on hand proportions. Our results reveal a large disparity of manipulative potentials among anthropoid hands. From the aspect of hand proportions, the human hand has the best manipulative potential among anthropoids. However, the species with a manipulative potential closer to that of humans are not our nearest relatives, chimpanzees, but rather, are certain monkey species. In combination with the phylogenetically informed morphometric analyses, our results suggest that the morphological changes of non-human anthropoid hands did not coevolve with the brain to facilitate the manipulative ability during the evolutionary process, although the manipulative ability is a survival skill. The changes in non-human anthropoid hands may have more likely evolved under selective pressure for locomotion than manipulation. © 2016 The Author(s).

  2. New insights into the burden and costs of multiple sclerosis in Europe: Results for Russia.

    PubMed

    Boyko, Alexey; Kobelt, Gisela; Berg, Jenny; Boyko, Olga; Popova, Ekaterina; Capsa, Daniela; Eriksson, Jennifer

    2017-08-01

    In order to assess the value of management strategies in multiple sclerosis (MS), outcome data have to be combined with cost data. This, in turn, requires that cost data be regularly updated. This study is part of a cross-sectional retrospective study in 16 countries collecting current data on resource consumption, work capacity and health-related quality of life (HQoL). Descriptive analyses are presented by level of severity; costs are estimated in the societal perspective, in RUB 2015. A total of 208 patients (mean age: 38.5 years) participated in the Russian study; 97% were below retirement age, and of these, 49% were employed. MS was reported to affect productivity at work in 63% of patients. Overall, 87% and 41% of patients felt that fatigue and cognition were a problem. The mean utility and costs were 0.769 and 578,000 RUB at Expanded Disability Status Scale (EDSS) 0-3, 0.509 and 826,000 RUB at EDSS 4-6.5, and 0.071 and 1,013,000 RUB at EDSS 7-9. The average cost of a relapse was 33,000 RUB. This study illustrates the burden of MS on Russian patients and provides current data that are important for developing health policies.

  3. Hand and goods judgment algorithm based on depth information

    NASA Astrophysics Data System (ADS)

    Li, Mingzhu; Zhang, Jinsong; Yan, Dan; Wang, Qin; Zhang, Ruiqi; Han, Jing

    2016-03-01

    A tablet computer with a depth camera and a color camera is loaded on a traditional shopping cart. The inside information of the shopping cart is obtained by two cameras. In the shopping cart monitoring field, it is very important for us to determine whether the customer with goods in or out of the shopping cart. This paper establishes a basic framework for judging empty hand, it includes the hand extraction process based on the depth information, process of skin color model building based on WPCA (Weighted Principal Component Analysis), an algorithm for judging handheld products based on motion and skin color information, statistical process. Through this framework, the first step can ensure the integrity of the hand information, and effectively avoids the influence of sleeve and other debris, the second step can accurately extract skin color and eliminate the similar color interference, light has little effect on its results, it has the advantages of fast computation speed and high efficiency, and the third step has the advantage of greatly reducing the noise interference and improving the accuracy.

  4. Multi-fingered robotic hand

    NASA Technical Reports Server (NTRS)

    Ruoff, Carl F. (Inventor); Salisbury, Kenneth, Jr. (Inventor)

    1990-01-01

    A robotic hand is presented having a plurality of fingers, each having a plurality of joints pivotally connected one to the other. Actuators are connected at one end to an actuating and control mechanism mounted remotely from the hand and at the other end to the joints of the fingers for manipulating the fingers and passing externally of the robot manipulating arm in between the hand and the actuating and control mechanism. The fingers include pulleys to route the actuators within the fingers. Cable tension sensing structure mounted on a portion of the hand are disclosed, as is covering of the tip of each finger with a resilient and pliable friction enhancing surface.

  5. AUTOMATIC HAND COUNTER

    DOEpatents

    Mann J.R.; Wainwright, A.E.

    1963-06-11

    An automatic, personnel-operated, alpha-particle hand monitor is described which functions as a qualitative instrument to indicate to the person using it whether his hands are cold'' or hot.'' The monitor is activated by a push button and includes several capacitor-triggered thyratron tubes. Upon release of the push button, the monitor starts the counting of the radiation present on the hands of the person. If the count of the radiation exceeds a predetermined level within a predetermined time, then a capacitor will trigger a first thyratron tube to light a hot'' lamp. If, however, the count is below such level during this time period, another capacitor will fire a second thyratron to light a safe'' lamp. (AEC)

  6. Access to Waterless Hand Sanitizer Improves Student Hand Hygiene Behavior in Primary Schools in Nairobi, Kenya

    PubMed Central

    Pickering, Amy J.; Davis, Jennifer; Blum, Annalise G.; Scalmanini, Jenna; Oyier, Beryl; Okoth, George; Breiman, Robert F.; Ram, Pavani K.

    2013-01-01

    Handwashing is difficult in settings with limited resources and water access. In primary schools within urban Kibera, Kenya, we investigated the impact of providing waterless hand sanitizer on student hand hygiene behavior. Two schools received a waterless hand sanitizer intervention, two schools received a handwashing with soap intervention, and two schools received no intervention. Hand cleaning behavior after toilet use was monitored for 2 months using structured observation. Hand cleaning after toileting was 82% at sanitizer schools (N = 2,507 toileting events), 38% at soap schools (N = 3,429), and 37% at control schools (N = 2,797). Students at sanitizer schools were 23% less likely to have observed rhinorrhea than control students (P = 0.02); reductions in student-reported gastrointestinal and respiratory illness symptoms were not statistically significant. Providing waterless hand sanitizer markedly increased student hand cleaning after toilet use, whereas the soap intervention did not. Waterless hand sanitizer may be a promising option to improve student hand cleansing behavior, particularly in schools with limited water access. PMID:23836575

  7. Smart Hand For Manipulators

    NASA Astrophysics Data System (ADS)

    Fiorini, Paolo

    1987-10-01

    Sensor based, computer controlled end effectors for mechanical arms are receiving more and more attention in the robotics industry, because commonly available grippers are only adequate for simple pick and place tasks. This paper describes the current status of the research at JPL on a smart hand for a Puma 560 robot arm. The hand is a self contained, autonomous system, capable of executing high level commands from a supervisory computer. The mechanism consists of parallel fingers, powered by a DC motor, and controlled by a microprocessor embedded in the hand housing. Special sensors are integrated in the hand for measuring the grasp force of the fingers, and for measuring forces and torques applied between the arm and the surrounding environment. Fingers can be exercised under position, velocity and force control modes. The single-chip microcomputer in the hand executes the tasks of communication, data acquisition and sensor based motor control, with a sample cycle of 2 ms and a transmission rate of 9600 baud. The smart hand described in this paper represents a new development in the area of end effector design because of its multi-functionality and autonomy. It will also be a versatile test bed for experimenting with advanced control schemes for dexterous manipulation.

  8. Big Hand Produces CD-I World Disc--First Title Authored Entirely with MediaMogul.

    ERIC Educational Resources Information Center

    Buckman, Brad; Grant, Valerie

    1993-01-01

    Discusses Big Hand Productions' development of CD-I-WORLD, an interactive multimedia magazine on compact disk, designed for mass appeal and complete with advertising. Features of MediaMogul, the prepackaged authoring software that made production of this innovation possible, are described. Sample screen displays are included. (EA)

  9. Nonrheumatoid Arthritis of the Hand.

    PubMed

    Lans, Jonathan; Machol, Jacques A; Deml, Christian; Chen, Neal C; Jupiter, Jesse B

    2018-01-01

    Arthropathy of the hand is commonly encountered. Contributing factors such as aging, trauma, and systemic illness all may have a role in the evolution of this pathology. Besides rheumatoid arthritis, other diseases affect the small joints of the hand. A review of nonrheumatoid hand arthropathies is beneficial for clinicians to recognize these problems. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  10. The Marble-Hand Illusion

    PubMed Central

    Senna, Irene; Maravita, Angelo; Bolognini, Nadia; Parise, Cesare V.

    2014-01-01

    Our body is made of flesh and bones. We know it, and in our daily lives all the senses constantly provide converging information about this simple, factual truth. But is this always the case? Here we report a surprising bodily illusion demonstrating that humans rapidly update their assumptions about the material qualities of their body, based on their recent multisensory perceptual experience. To induce a misperception of the material properties of the hand, we repeatedly gently hit participants' hand with a small hammer, while progressively replacing the natural sound of the hammer against the skin with the sound of a hammer hitting a piece of marble. After five minutes, the hand started feeling stiffer, heavier, harder, less sensitive, unnatural, and showed enhanced Galvanic skin response (GSR) to threatening stimuli. Notably, such a change in skin conductivity positively correlated with changes in perceived hand stiffness. Conversely, when hammer hits and impact sounds were temporally uncorrelated, participants did not spontaneously report any changes in the perceived properties of the hand, nor did they show any modulation in GSR. In two further experiments, we ruled out that mere audio-tactile synchrony is the causal factor triggering the illusion, further demonstrating the key role of material information conveyed by impact sounds in modulating the perceived material properties of the hand. This novel bodily illusion, the ‘Marble-Hand Illusion', demonstrates that the perceived material of our body, surely the most stable attribute of our bodily self, can be quickly updated through multisensory integration. PMID:24621793

  11. The mirror illusion: does proprioceptive drift go hand in hand with sense of agency?

    PubMed Central

    Tajima, Daisuke; Mizuno, Tota; Kume, Yuichiro; Yoshida, Takako

    2015-01-01

    Vection can be regarded as the illusion of “whole-body” position perception. In contrast, the mirror illusion is that of “body-part” position perception. When participants viewed their left hands in a mirror positioned along the midsaggital axis while moving both hands synchronously, they hardly noticed the spatial offset between the hand in the mirror and the obscured real right hand. This illusion encompasses two phenomena: proprioceptive drift and sense of agency. Proprioceptive drift represented a perceptual change in the position of the obscured hand relative to that of the hand in the mirror. Sense of agency referred to the participants' subjective sense of controlling body image as they would their own bodies. We examined the spatial offset between these two phenomena. Participants responded to a two-alternative forced choice (2AFC) question regarding the subjective position of their right hands and questionnaires regarding sense of agency at various positions of the right hand. We analyzed the 2AFC data using a support vector machine and compared its classification result and the questionnaire results. Our data analysis suggested that the two phenomena were observed in concentric space, but the estimated range of the proprioceptive drift was slightly narrower than the range of agency. Although this outcome can be attributed to differences in measurement or analysis, to our knowledge, this is the first report to suggest that proprioceptive drift and sense of agency are concentric and almost overlap. PMID:25774145

  12. Effects of hand gestures on auditory learning of second-language vowel length contrasts.

    PubMed

    Hirata, Yukari; Kelly, Spencer D; Huang, Jessica; Manansala, Michael

    2014-12-01

    Research has shown that hand gestures affect comprehension and production of speech at semantic, syntactic, and pragmatic levels for both native language and second language (L2). This study investigated a relatively less explored question: Do hand gestures influence auditory learning of an L2 at the segmental phonology level? To examine auditory learning of phonemic vowel length contrasts in Japanese, 88 native English-speaking participants took an auditory test before and after one of the following 4 types of training in which they (a) observed an instructor in a video speaking Japanese words while she made syllabic-rhythm hand gesture, (b) produced this gesture with the instructor, (c) observed the instructor speaking those words and her moraic-rhythm hand gesture, or (d) produced the moraic-rhythm gesture with the instructor. All of the training types yielded similar auditory improvement in identifying vowel length contrast. However, observing the syllabic-rhythm hand gesture yielded the most balanced improvement between word-initial and word-final vowels and between slow and fast speaking rates. The overall effect of hand gesture on learning of segmental phonology is limited. Implications for theories of hand gesture are discussed in terms of the role it plays at different linguistic levels.

  13. Effect of Hand Antisepsis Agent Selection and Population Characteristics on Surgical Site Infection Pathogens.

    PubMed

    Oriel, Brad S; Chen, Qi; Wong, Kevin; Itani, Kamal M F

    Selection of a pre-operative hand antisepsis agent has not been studied in relation to surgical site infection (SSI) culture data. In our hospital, we introduced an alcohol-based hand rub (ABR) in 2012 as an alternative to traditional aqueous surgical scrubs (TSS). It was the goal of this study to review any effect of this implementation on SSI pathogen characteristics. In addition, we sought to compare our SSI culture data with available National Healthcare Safety Network (NHSN) data. We hypothesized that SSI pathogens and resistant isolates are affected by surgical hand antisepsis technique. Data collected prospectively between 2007 and 2014 were retrospectively analyzed for two time periods at the Veterans Affairs Boston Healthcare System (VABHS): Before ABR implementation (TSS group) and after (ABR group). Pathogen distribution and pathogenic isolate resistance profiles were compared for TSS and ABR, and similar comparisons, along with procedure-associated SSI comparisons, were made between VABHS and NHSN. All VABHS data were interpreted and categorized according to NHSN definitions. Compared with TSS (n = 4,051), ABR (n = 2,293) had a greater rate of Staphylococcus aureus (42.6% vs. 38.0%), Escherichia coli (12.8% vs. 9.9%), Pseudomonas aeruginosa (8.5% vs. 2.8%), and Enterobacter spp. (10.6% vs. 2.8%), and a lower rate of Klebsiella pneumoniae/K. oxytoca (4.3% vs. 8.5%) cultured from superficial and deep SSIs (p < 0.05). Of the S. aureus isolates, 35.0% and 44.4% were resistant to oxacillin/methicillin (MRSA) in ABR and TSS, respectively (p = 0.06). Looking at all SSIs, coagulase-negative staphylococci and K. pneumoniae/K. oxytoca at VABHS (4.0% and 10.4%, respectively) accounted for the biggest difference from NHSN (11.7% and 4.0%, respectively). Aside from MRSA, where there was no difference between VABHS and NHSN (42.9% vs. 43.7%, respectively; p = 0.87), statistically significant (p < 0.05) differences were observed among multi

  14. Long term type 1 diabetes is associated with hand pain, disability and stiffness but not with structural hand osteoarthritis features – The Dialong hand study

    PubMed Central

    Magnusson, Karin; Bech Holte, Kristine; Juel, Niels Gunnar; Brox, Jens Ivar; Hagen, Kåre Birger; Haugen, Ida Kristin; Berg, Tore Julsrud

    2017-01-01

    Objective To explore whether having long-term type 1 diabetes (>45 years) is associated with a higher prevalence of radiographic hand OA, erosive hand OA and increased hand pain, disability and stiffness. Methods In total N = 96 persons with type 1 diabetes diagnosed before 1970 were included (mean [SD] age: 62.2 [7.4], mean [SD] HbA1c: 7.43 [0.80] and N = 49 [51%] men). Regular measurements of their HbA1c were obtained till 2015. We included N = 69 healthy controls without any diabetes (mean [SD] age: 63.0 [7.0], mean [SD] HbA1c: 5.41 [0.32], N = 29 [42%] men). The groups were compared for radiographic hand OA (Kellgren-Lawrence grade ≥2 in ≥1 joint) and erosive hand OA (central erosions in ≥1 joint), Australian/Canadian index (AUSCAN) for hand pain, disability and stiffness using regression analyses adjusted for age, sex, educational level and waist circumference. Results We found no associations between having long term type 1 diabetes and more prevalent radiographic hand OA (OR = 0.83, 95% CI = 0.38–1.81). We found a trend towards higher prevalence of erosive hand OA in diabetes patients (OR = 2.96, 95% CI = 0.82–10.64). Strong and consistent associations were observed between long term type 1 diabetes and increased hand pain (B = 2.78, 95% CI = 1.65–3.91), disability (B = 5.30, 95% CI = 3.48–7.12) and stiffness (B = 2.00, 95% CI = 1.33–2.67). These associations were particularly strong for women and participants below the median age of 61 years. Conclusion Long-term type 1 diabetes was not associated with radiographic hand OA, but was strongly associated with hand pain, disability and stiffness. The association between diabetes and erosive hand OA warrants further investigation. PMID:28510594

  15. Personal hand gel for improved hand hygiene compliance on the regional anesthesia team.

    PubMed

    Parks, Colby L; Schroeder, Kristopher M; Galgon, Richard E

    2015-12-01

    Hand hygiene reduces healthcare-associated infections, and several recent publications have examined hand hygiene in the perioperative period. Our institution's policy is to perform hand hygiene before and after patient contact. However, observation suggests poor compliance. This is a retrospective review of a quality improvement database showing the effect of personal gel dispensers on perioperative hand hygiene compliance on a regional anesthesia team. Healthcare providers assigned to the Acute Pain Service were observed for compliance with hand hygiene policy during a quality improvement initiative. Provider type and compliance were prospectively recorded in a database. Team members were then given a personal gel dispensing device and again observed for compliance. We have retrospectively reviewed this database to determine the effects of this intervention. Of the 307 encounters observed, 146 were prior to implementing personal gel dispensers. Compliance was 34%. Pre- and post-patient contact compliances were 23 and 43%, respectively. For 161 encounters after individual gel dispensers were provided, compliance was 63%. Pre- and post-patient contact compliances were 53 and 72%, respectively. Improvement in overall compliance from 34 to 63% was significant. On the Acute Pain Service, compliance with hand hygiene policy improves when individual sanitation gel dispensing devices are worn on the person.

  16. Headache-attributed burden and its impact on productivity and quality of life in Russia: structured healthcare for headache is urgently needed.

    PubMed

    Ayzenberg, I; Katsarava, Z; Sborowski, A; Chernysh, M; Osipova, V; Tabeeva, G; Steiner, T J

    2014-05-01

    The study evaluated headache-attributed burden and its impact on productivity and quality of life (QoL) in Russia. Its purpose was to support recommendations for change. A countrywide population-based random sample of 2725 biologically unrelated adults (aged 18-65 years) in 35 cities and nine rural areas of Russia were interviewed in a door-to-door survey. The structured questionnaire enquired into symptom burden, functional disability, lost productive time and QoL (applying the WHOQoL-8 question set), as well as willingness to pay (WTP) for adequate headache treatment, if it were available. Mean lost paid-work days due to headache in the previous 3 months were 1.9 ± 4.2, and mean lost household work days were 3.4 ± 5.7. The estimated annual indirect cost of primary headache disorders was USD 22.8 billion, accounting for 1.75% of gross domestic product. QoL was reduced by all types of primary headaches. According to WHOQoL-8, it was significantly lower in those with headache on ≥15 days/month than in those with episodic headache (24.7 ± 4.6 vs. 28.1 ± 5.0; P < 0.05) and lower in those with migraine than in those with tension-type headache (TTH) (27.1 ± 4.9 vs. 28.8 ± 5.0; P < 0.05). Average WTP for adequate headache treatment was RUB 455 ± 494 per month (median RUB 300), a sum sufficient in most cases, and correlated with illness severity (higher for headache on ≥15 days/month than for migraine, and for migraine than for TTH). Headache is common, burdensome and costly in Russia and, manifestly, poorly mitigated by existing healthcare. Structured healthcare services for headache need to be urgently put in place. © 2014 The Author(s) European Journal of Neurology © 2014 EFNS.

  17. Mentorship for operational research capacity building: hands-on or hands-off?

    PubMed

    Harries, A D; Marais, B; Kool, B; Ram, S; Kumar, A M V; Gounder, S; Viney, K; Brostrom, R; Roseveare, C; Bissell, K; Reid, A J; Zachariah, R; Hill, P C

    2014-06-21

    Mentorship is a key feature of operational research training courses run by the International Union Against Tuberculosis and Lung Disease and Médecins Sans Frontières. During the recent South Pacific paper writing module, the faculty discussed 'hands-on' mentorship (direct technical assistance) vs. 'hands-off' mentorship (technical advice). This article explores the advantages and disadvantages of each approach. Our collective experience indicates that 'hands-on' mentorship is a valuable learning experience for the participant and a rewarding experience for the mentor. This approach increases the likelihood of successful course completion, including publishing a well written paper. However, mentors must allow participants to lead and take ownership of the paper, in keeping with a first author position.

  18. Recognizing the Operating Hand and the Hand-Changing Process for User Interface Adjustment on Smartphones.

    PubMed

    Guo, Hansong; Huang, He; Huang, Liusheng; Sun, Yu-E

    2016-08-20

    As the size of smartphone touchscreens has become larger and larger in recent years, operability with a single hand is getting worse, especially for female users. We envision that user experience can be significantly improved if smartphones are able to recognize the current operating hand, detect the hand-changing process and then adjust the user interfaces subsequently. In this paper, we proposed, implemented and evaluated two novel systems. The first one leverages the user-generated touchscreen traces to recognize the current operating hand, and the second one utilizes the accelerometer and gyroscope data of all kinds of activities in the user's daily life to detect the hand-changing process. These two systems are based on two supervised classifiers constructed from a series of refined touchscreen trace, accelerometer and gyroscope features. As opposed to existing solutions that all require users to select the current operating hand or confirm the hand-changing process manually, our systems follow much more convenient and practical methods and allow users to change the operating hand frequently without any harm to the user experience. We conduct extensive experiments on Samsung Galaxy S4 smartphones, and the evaluation results demonstrate that our proposed systems can recognize the current operating hand and detect the hand-changing process with 94.1% and 93.9% precision and 94.1% and 93.7% True Positive Rates (TPR) respectively, when deciding with a single touchscreen trace or accelerometer-gyroscope data segment, and the False Positive Rates (FPR) are as low as 2.6% and 0.7% accordingly. These two systems can either work completely independently and achieve pretty high accuracies or work jointly to further improve the recognition accuracy.

  19. A Novel Solubility-Enhanced Rubusoside-Based Micelles for Increased Cancer Therapy

    NASA Astrophysics Data System (ADS)

    Zhang, Meiying; Dai, Tongcheng; Feng, Nianping

    2017-04-01

    Many anti-cancer drugs have a common problem of poor solubility. Increasing the solubility of the drugs is very important for its clinical applications. In the present study, we revealed that the solubility of insoluble drugs was significantly enhanced by adding rubusoside (RUB). Further, it was demonstrated that RUB could form micelles, which was well characterized by Langmuir monolayer investigation, transmission electron microscopy, atomic-force microscopy, and cryogenic transmission electron microscopy. The RUB micelles were ellipsoid with the horizontal distance of 25 nm and vertical distance of 1.2 nm. Insoluble synergistic anti-cancer drugs including curcumin and resveratrol were loaded in RUB to form anti-cancer micelles RUB/CUR + RES. MTT assay showed that RUB/CUR + RES micelles had more significant toxicity on MCF-7 cells compared to RUB/CUR micelles + RUB/RES micelles. More importantly, it was confirmed that RUB could load other two insoluble drugs together for remarkably enhanced anti-cancer effect compared to that of RUB/one drug + RUB/another drug. Overall, we concluded that RUB-based micelles could efficiently load insoluble drugs for enhanced anti-cancer effect.

  20. Hands of early primates.

    PubMed

    Boyer, Doug M; Yapuncich, Gabriel S; Chester, Stephen G B; Bloch, Jonathan I; Godinot, Marc

    2013-12-01

    Questions surrounding the origin and early evolution of primates continue to be the subject of debate. Though anatomy of the skull and inferred dietary shifts are often the focus, detailed studies of postcrania and inferred locomotor capabilities can also provide crucial data that advance understanding of transitions in early primate evolution. In particular, the hand skeleton includes characteristics thought to reflect foraging, locomotion, and posture. Here we review what is known about the early evolution of primate hands from a comparative perspective that incorporates data from the fossil record. Additionally, we provide new comparative data and documentation of skeletal morphology for Paleogene plesiadapiforms, notharctines, cercamoniines, adapines, and omomyiforms. Finally, we discuss implications of these data for understanding locomotor transitions during the origin and early evolutionary history of primates. Known plesiadapiform species cannot be differentiated from extant primates based on either intrinsic hand proportions or hand-to-body size proportions. Nonetheless, the presence of claws and a different metacarpophalangeal [corrected] joint form in plesiadapiforms indicate different grasping mechanics. Notharctines and cercamoniines have intrinsic hand proportions with extremely elongated proximal phalanges and digit rays relative to metacarpals, resembling tarsiers and galagos. But their hand-to-body size proportions are typical of many extant primates (unlike those of tarsiers, and possibly Teilhardina, which have extremely large hands). Non-adapine adapiforms and omomyids exhibit additional carpal features suggesting more limited dorsiflexion, greater ulnar deviation, and a more habitually divergent pollex than observed plesiadapiforms. Together, features differentiating adapiforms and omomyiforms from plesiadapiforms indicate increased reliance on vertical prehensile-clinging and grasp-leaping, possibly in combination with predatory behaviors in

  1. iHandRehab: an interactive hand exoskeleton for active and passive rehabilitation.

    PubMed

    Li, Jiting; Zheng, Ruoyin; Zhang, Yuru; Yao, Jianchu

    2011-01-01

    This paper presents an interactive exoskeleton device for hand rehabilitation, iHandRehab, which aims to satisfy the essential requirements for both active and passive rehabilitation motions. iHandRehab is comprised of exoskeletons for the thumb and index finger. These exoskeletons are driven by distant actuation modules through a cable/sheath transmission mechanism. The exoskeleton for each finger has 4 degrees of freedom (DOF), providing independent control for all finger joints. The joint motion is accomplished by a parallelogram mechanism so that the joints of the device and their corresponding finger joints have the same angular displacement when they rotate. Thanks to this design, the joint angles can be measured by sensors real time and high level motion control is therefore made very simple without the need of complicated kinematics. The paper also discusses important issues when the device is used by different patients, including its adjustable joint range of motion (ROM) and adjustable range of phalanx length (ROPL). Experimentally collected data show that the achieved ROM is close to that of a healthy hand and the ROPL covers the size of a typical hand, satisfying the size need of regular hand rehabilitation. In order to evaluate the performance when it works as a haptic device in active mode, the equivalent moment of inertia (MOI) of the device is calculated. The results prove that the device has low inertia which is critical in order to obtain good backdrivability. Experimental analysis shows that the influence of friction accounts for a large portion of the driving torque and warrants future investigation. © 2011 IEEE

  2. Hand2 loss-of-function in Hand1-expressing Cells Reveals Distinct Roles In Epicardial And Coronary Vessel Development

    PubMed Central

    Barnes, Ralston M.; Firulli, Beth A.; VanDusen, Nathan J.; Morikawa, Yuka; Conway, Simon J.; Cserjesi, Peter; Vincentz, Joshua W.; Firulli, Anthony B.

    2011-01-01

    Rationale The bHLH transcription factors Hand1 and Hand2 are essential for embryonic development. Given their requirement for cardiogenesis, it is imperative to determine their impact on cardiovascular function. Objective Deduce the role of Hand2 within the epicardium. Method & Results We engineered a Hand1 allele expressing Cre recombinase. Cardiac Hand1 expression is largely limited to cells of the primary heart field, overlapping little with Hand2 expression. Hand1 is expressed within the septum transversum (ST) and the Hand1-lineage marks the proepicardial organ and epicardium. To examine Hand factor functional overlap, we conditionally deleted Hand2 from Hand1-expressing cells. Hand2 mutants display defective epicardialization and fail to form coronary arteries, coincident with altered ECM deposition and Pdgfr expression. Conclusion These data demonstrate a hierarchal relationship whereby transient Hand1 ST expression defines epicardial precursors that are subsequently dependent upon Hand2 function. PMID:21350214

  3. Do WiFi-based hand hygiene dispenser systems increase hand hygiene compliance?

    PubMed

    Scheithauer, Simone; Bickenbach, Johannes; Heisel, Hans; Fehling, Patrick; Marx, Gernot; Lemmen, Sebastian

    2018-05-17

    Innovative methods to ensure better compliance in hand hygiene are urgently needed. The aim of this study was to determine if WiFi-based hand hygiene dispenser-driven self-assessment systems (Wireless Fidelity, WiFi-dispenser) can support the work of infection control teams. Our results suggest that the continuous monitoring of dispenser usage can be a valuable addition to infection prevention and control programs, when used in a bundle in combination with conventional hand hygiene training. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  4. Hand coverage by alcohol-based handrub varies: Volume and hand size matter.

    PubMed

    Zingg, Walter; Haidegger, Tamas; Pittet, Didier

    2016-12-01

    Visitors of an infection prevention and control conference performed hand hygiene with 1, 2, or 3 mL ultraviolet light-traced alcohol-based handrub. Coverage of palms, dorsums, and fingertips were measured by digital images. Palms of all hand sizes were sufficiently covered when 2 mL was applied, dorsums of medium and large hands were never sufficiently covered. Palmar fingertips were sufficiently covered when 2  or 3 mL was applied, and dorsal fingertips were never sufficiently covered. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  5. Illumination-invariant hand gesture recognition

    NASA Astrophysics Data System (ADS)

    Mendoza-Morales, América I.; Miramontes-Jaramillo, Daniel; Kober, Vitaly

    2015-09-01

    In recent years, human-computer interaction (HCI) has received a lot of interest in industry and science because it provides new ways to interact with modern devices through voice, body, and facial/hand gestures. The application range of the HCI is from easy control of home appliances to entertainment. Hand gesture recognition is a particularly interesting problem because the shape and movement of hands usually are complex and flexible to be able to codify many different signs. In this work we propose a three step algorithm: first, detection of hands in the current frame is carried out; second, hand tracking across the video sequence is performed; finally, robust recognition of gestures across subsequent frames is made. Recognition rate highly depends on non-uniform illumination of the scene and occlusion of hands. In order to overcome these issues we use two Microsoft Kinect devices utilizing combined information from RGB and infrared sensors. The algorithm performance is tested in terms of recognition rate and processing time.

  6. Hand skin reconstruction from skeletal landmarks.

    PubMed

    Lefèvre, P; Van Sint Jan, S; Beauthier, J P; Rooze, M

    2007-11-01

    Many studies related to three-dimensional facial reconstruction have been previously reported. On the other hand, no extensive work has been found in the literature about hand reconstruction as an identification method. In this paper, the feasibility of virtual reconstruction of hand skin based on (1) its skeleton and (2) another hand skin and skeleton used as template was assessed. One cadaver hand and one volunteer's hand have been used. For the two hands, computer models of the bones and skin were obtained from computerized tomography. A customized software allowed locating spatial coordinates of bony anatomical landmarks on the models. From these landmarks, the spatial relationships between the models were determined and used to interpolate the missing hand skin. The volume of the interpolated skin was compared to the real skin obtained from medical imaging for validation. Results seem to indicate that such a method is of interest to give forensic investigators morphological clues related to an individual hand skin based on its skeleton. Further work is in progress to finalize the method.

  7. A natural approach to convey numerical digits using hand activity recognition based on hand shape features

    NASA Astrophysics Data System (ADS)

    Chidananda, H.; Reddy, T. Hanumantha

    2017-06-01

    This paper presents a natural representation of numerical digit(s) using hand activity analysis based on number of fingers out stretched for each numerical digit in sequence extracted from a video. The analysis is based on determining a set of six features from a hand image. The most important features used from each frame in a video are the first fingertip from top, palm-line, palm-center, valley points between the fingers exists above the palm-line. Using this work user can convey any number of numerical digits using right or left or both the hands naturally in a video. Each numerical digit ranges from 0 to9. Hands (right/left/both) used to convey digits can be recognized accurately using the valley points and with this recognition whether the user is a right / left handed person in practice can be analyzed. In this work, first the hand(s) and face parts are detected by using YCbCr color space and face part is removed by using ellipse based method. Then, the hand(s) are analyzed to recognize the activity that represents a series of numerical digits in a video. This work uses pixel continuity algorithm using 2D coordinate geometry system and does not use regular use of calculus, contours, convex hull and datasets.

  8. Mentorship for operational research capacity building: hands-on or hands-off?

    PubMed Central

    Marais, B.; Kool, B.; Ram, S.; Kumar, A. M. V.; Gounder, S.; Viney, K.; Brostrom, R.; Roseveare, C.; Bissell, K.; Reid, A. J.; Zachariah, R.; Hill, P. C.

    2014-01-01

    Mentorship is a key feature of operational research training courses run by the International Union Against Tuberculosis and Lung Disease and Médecins Sans Frontières. During the recent South Pacific paper writing module, the faculty discussed ‘hands-on’ mentorship (direct technical assistance) vs. ‘hands-off’ mentorship (technical advice). This article explores the advantages and disadvantages of each approach. Our collective experience indicates that ‘hands-on’ mentorship is a valuable learning experience for the participant and a rewarding experience for the mentor. This approach increases the likelihood of successful course completion, including publishing a well written paper. However, mentors must allow participants to lead and take ownership of the paper, in keeping with a first author position. PMID:26477290

  9. An ergonomic approach to design hand tool for agricultural production.

    PubMed

    Khidiya, Mahendra Singh; Bhardwaj, Awadhesh

    2012-01-01

    Hand tool mechanisms designed to reduce the risk factors have rarely been studied. In this paper it is analyze trowel firstly designing in CATIA and then its Finite Element Analysis has been carried out by ABAQUS. The main emphasis is on finding stresses by using this software, then removing them by suitable mechanical working on tool & ergonomic change in the design of handle to make it more comfortable. Body part discomfort score and overall discomfort rating experienced by the subjects had also been estimated. During the muscular activity workers physiological responses i.e. energy expenditure rate, oxygen consumption rate and heart rate increases. This increase in physiological responses is related to the type, intensity and duration of work and thus sets limits to the performance of heavy work. In this paper oxygen consumption rate and heart rate was used for physiological cost estimation. These parameters were measured by Computerized Ambulatory Metabolic Measurement System K4b2.

  10. Relative effectiveness of dominant versus non-dominant hand position for rescuer's side of approach during chest compressions between right-handed and left-handed novice rescuers.

    PubMed

    You, Je Sung; Kim, Hoon; Park, Jung Soo; Baek, Kyung Min; Jang, Mun Sun; Lee, Hye Sun; Chung, Sung Phil; Kim, SeungWhan

    2015-03-01

    The major components affecting high quality cardiopulmonary resuscitation (CPR) have been defined as the ability of the rescuer, hand position, position of the rescuer and victim, depth and rate of chest compressions, and fatigue. Until now, there have been no studies on dominant versus non-dominant hand position and the rescuer's side of approach. This study was designed to evaluate the effectiveness of hand position and approach side on the quality of CPR between right-handed (RH) and left-handed (LH) novice rescuers. 44 health science university students with no previous experience of basic life support (BLS) volunteered for the study. We divided volunteers into two groups by handedness. Adult BLS was performed on a manikin for 2 min in each session. The sequences were randomly performed on the manikin's left side of approach (Lap) with the rescuer's left hand in contact with the sternum (Lst), Lap/Rst, Rap/Lst and Rap/Rst. We compared the quality of chest compressions between the RH and LH groups according to predetermined positions. A significant decrease in mean compression depth between the two groups was only observed when rescuers performed in the Rap/Lst scenario, regardless of hand dominance. The frequency of correct hand placement also significantly decreased in the Lap/Rst position for the LH group. The performance of novice rescuers during chest compressions is influenced by the position of the dominant hand and the rescuer's side of approach. In CPR training and real world situations, a novice rescuer, regardless of handedness, should consider hand positions for contacting the sternum identical to the side of approach after approaching from the nearest and most accessible side, for optimal CPR performance. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. [The diabetic hand].

    PubMed

    Schiavon, F; Circhetta, C; Dani, L

    2004-01-01

    Diabetes mellitus is a chronic metabolic condition characterized by persistent hyperglycaemia with resultant morbidity and mortality related to its microvascular and macrovascular complications. In addition diabetes is also associated with several musculoskeletal disorders of the hand, that can be debilitating. There is increased incidence of these abnormalities in patients with type 1 and type 2 diabetes compared with the general population, related to disease duration but not to the age or sex. Typical diabetes associated hand condition include the palmar flexor tenosynovitis, Dupuytren's contracture, syndrome of limited joint mobility, carpal tunnel syndrome, Charcot arthropathy and reflex sympathetic dystrophy. Maintaining good glycaemic control by exercise, diet and drugs improves or prevents the development of these hand rheumatic condition. In this brief report we review the rational therapeutic approach to these disorders.

  12. Experiences and consequences for women with hand-arm vibration injuries.

    PubMed

    Bylund, Sonya Hörnqwist; Ahlgren, Christina

    2010-01-01

    Vibrating machines are used in a variety of occupations. Exposure to hand-arm vibration can cause vascular, neurological, and muscular symptoms in the hands and arms. This qualitative study provides a deeper understanding of the consequences of vibration injuries in women. In depth interviews were conducted with eight women with vibration injuries. The women were metal and wood product assemblers and dental personnel. The transcribed interviews were analyzed in accordance with the grounded theory method. The core category in the findings was "another life". This was constructed by the categories "consequences for everyday activities", "work performance", "household duties", "leisure", and "self perception" and shows that the injury had affected most parts of the women's lives and decreased their quality of life. The importance of well-functioning hands in all activities was highlighted. Reduced hand function due to numbness, muscle weakness, and pain caused restricted abilities to perform activities at work, at home, and during leisure time. The women described impact on their self-perception, as the injury had affected them in their roles as a worker, mother, and woman. The findings indicate that a vibration injury is a multidimensional problem that can affect every aspect of an individual's life. Health care providers should be aware of these complex consequences.

  13. Natural control capabilities of robotic hands by hand amputated subjects.

    PubMed

    Atzori, Manfredo; Gijsberts, Arjan; Caputo, Barbara; Muller, Henning

    2014-01-01

    People with transradial hand amputations who own a myoelectric prosthesis currently have some control capabilities via sEMG. However, the control systems are still limited and not natural. The Ninapro project is aiming at helping the scientific community to overcome these limits through the creation of publicly available electromyography data sources to develop and test machine learning algorithms. In this paper we describe the movement classification results gained from three subjects with an homogeneous level of amputation, and we compare them with the results of 40 intact subjects. The number of considered subjects can seem small at first sight, but it is not considering the literature of the field (which has to face the difficulty of recruiting trans-radial hand amputated subjects). The classification is performed with four different classifiers and the obtained balanced classification rates are up to 58.6% on 50 movements, which is an excellent result compared to the current literature. Successively, for each subject we find a subset of up to 9 highly independent movements, (defined as movements that can be distinguished with more than 90% accuracy), which is a deeply innovative step in literature. The natural control of a robotic hand in so many movements could lead to an immediate progress in robotic hand prosthetics and it could deeply change the quality of life of amputated subjects.

  14. Life-style factors and hand eczema.

    PubMed

    Anveden Berglind, I; Alderling, M; Meding, B

    2011-09-01

    Previous knowledge of the impact of certain life-style factors on hand eczema is scanty. To investigate a possible association between hand eczema and life-style factors such as obesity, physical exercise, stress, smoking and alcohol consumption. In a cross-sectional public health survey in Stockholm, Sweden, 27,994 (58%) randomly chosen individuals aged 18-64 years completed a postal questionnaire regarding physical and mental health, social relations, economic status and work. Of these, 27,793 individuals responded to the question regarding hand eczema and were included in the present study. The association between life-style factors and hand eczema was analysed by prevalence proportion ratios (PPR), using a generalized linear model. Hand eczema was more common among individuals who reported high stress levels, PPR 1·326 (95% CI 1·303-1·350). There was also a positive dose-response relationship between hand eczema and stress. Hand eczema was less common among individuals reporting high physical exercise, and most apparent in women, PPR 0·781 (95% CI 0·770-0·792). Men who reported high alcohol intake reported hand eczema less often, PPR 0·958 (95% CI 0·930-0·987). Obese individuals reported hand eczema more commonly, PPR 1·204 (95% CI 1·174-1·234). There was a slight increase of hand eczema among smokers, PPR 1·025 (95% CI 1·006-1·044). Hand eczema was more common in individuals who reported stress, obesity and smoking. In individuals who reported high physical exercise levels hand eczema was less common. As there appears to be an association between life-style factors and hand eczema it is important to consider life-style factors in clinical practice. © 2011 The Authors. BJD © 2011 British Association of Dermatologists.

  15. Grasp with hand and mouth: a kinematic study on healthy subjects.

    PubMed

    Gentilucci, M; Benuzzi, F; Gangitano, M; Grimaldi, S

    2001-10-01

    Neurons involved in grasp preparation with hand and mouth were previously recorded in the premotor cortex of monkey. The aim of the present kinematic study was to determine whether a unique planning underlies the act of grasping with hand and mouth in humans as well. In a set of four experiments, healthy subjects reached and grasped with the hand an object of different size while opening the mouth (experiments 1 and 3), or extending the other forearm (experiment 4), or the fingers of the other hand (experiment 5). In a subsequent set of three experiments, subjects grasped an object of different size with the mouth, while opening the fingers of the right hand (experiments 6-8). The initial kinematics of mouth and finger opening, but not of forearm extension, was affected by the size of the grasped object congruently with the size effect on initial grasp kinematics. This effect was due neither to visual presentation of the object, without the successive grasp motor act (experiment 2) nor to synchronism between finger and mouth opening (experiments 3, 7, and 8). In experiment 9 subjects grasped with the right hand an object of different size while pronouncing a syllable printed on the target. Mouth opening and sound production were affected by the grasped object size. The results of the present study are discussed according to the notion that in an action each motor act is prepared before the beginning of the motor sequence. Double grasp preparation can be used for successive motor acts on the same object as, for example, grasping food with the hand and ingesting it after bringing it to the mouth. We speculate that the circuits involved in double grasp preparation might have been the neural substrate where hand motor patterns used as primitive communication signs were transferred to mouth articulation system. This is in accordance with the hypothesis that Broca's area derives phylogenetically from the monkey premotor area where hand movements are controlled.

  16. The Effects of Industrial Protective Gloves and Hand Skin Temperatures on Hand Grip Strength and Discomfort Rating

    PubMed Central

    2017-01-01

    Daily working activities and functions require a high contribution of hand and forearm muscles in executing grip force. To study the effects of wearing different gloves on grip strength, under a variety of hand skin temperatures, an assessment of the maximum grip strength was performed with 32 healthy male workers with a mean age (standard deviation) of 30.44 (5.35) years wearing five industrial gloves at three hand skin temperatures. Their ages and anthropometric characteristics including body mass index (BMI), hand length, hand width, hand depth, hand palm, and wrist circumference were measured. The hand was exposed to different bath temperatures (5 °C, 25 °C, and 45 °C) and hand grip strength was measured using a Jamar hydraulic hand dynamometer with and without wearing the gloves (chemical protection glove, rubber insulating glove, anti-vibration impact glove, cotton yarn knitted glove, and RY-WG002 working glove). The data were analyzed using the Shapiro–Wilk test, Pearson correlation coefficient, Tukey test, and analysis of variance (ANOVA) of the within-subject design analysis. The results showed that wearing gloves significantly affected the maximum grip strength. Wearing the RY-WG002 working glove produced a greater reduction on the maximum grip when compared with the bare hand, while low temperatures (5 °C) had a significant influence on grip when compared to medium (25 °C) and high (45 °C) hand skin temperatures. In addition, participants felt more discomfort in both environmental extreme conditions. Furthermore, they reported more discomfort while wearing neoprene, rubber, and RY-WG002 working gloves. PMID:29207573

  17. Thermographic Evaluation of the Hands of Pig Slaughterhouse Workers Exposed to Cold Temperatures.

    PubMed

    Tirloni, Adriana Seára; Reis, Diogo Cunha Dos; Ramos, Eliane; Moro, Antônio Renato Pereira

    2017-07-26

    Brazil was rated the fourth leading producer and exporter of pork meat in the world. The aim of this study was to evaluate the temperature of the hands of pig slaughterhouse workers and its relation to the thermal sensation of the hands and the use of a cutting tool. The study included 106 workers in a pig slaughterhouse. An infrared camera FlirThermaCAM E320 (Flir Systems, Wilsonville, OR, USA) was used to collect the images of the dorsal and palmar surfaces of both hands. A numerical scale was used to obtain the thermal sensation. Chi-square test, Pearson correlation and Student's t test or Wilcoxon were used ( p ≤ 0.05). The majority of workers felt cold in the hands (66%) and workers who used the knife felt the coldest. There was an association between the thermal sensation and the use of knife ( p = 0.001). Workers who used the tool showed correlation between the thermal sensation and the temperatures of the left fingers, with a difference between the temperatures of the right and left hands of those who used the knife ( p ≤ 0.05). The hands (left) that manipulated the products presented the lowest temperatures. Findings indicate that employers of pig slaughterhouses should provide gloves with adequate thermal insulation to preserve the health of workers' hands.

  18. Thermographic Evaluation of the Hands of Pig Slaughterhouse Workers Exposed to Cold Temperatures

    PubMed Central

    Ramos, Eliane

    2017-01-01

    Brazil was rated the fourth leading producer and exporter of pork meat in the world. The aim of this study was to evaluate the temperature of the hands of pig slaughterhouse workers and its relation to the thermal sensation of the hands and the use of a cutting tool. The study included 106 workers in a pig slaughterhouse. An infrared camera FlirThermaCAM E320 (Flir Systems, Wilsonville, OR, USA) was used to collect the images of the dorsal and palmar surfaces of both hands. A numerical scale was used to obtain the thermal sensation. Chi-square test, Pearson correlation and Student’s t test or Wilcoxon were used (p ≤ 0.05). The majority of workers felt cold in the hands (66%) and workers who used the knife felt the coldest. There was an association between the thermal sensation and the use of knife (p = 0.001). Workers who used the tool showed correlation between the thermal sensation and the temperatures of the left fingers, with a difference between the temperatures of the right and left hands of those who used the knife (p ≤ 0.05). The hands (left) that manipulated the products presented the lowest temperatures. Findings indicate that employers of pig slaughterhouses should provide gloves with adequate thermal insulation to preserve the health of workers’ hands. PMID:28933764

  19. Hand specific representations in language comprehension.

    PubMed

    Moody-Triantis, Claire; Humphreys, Gina F; Gennari, Silvia P

    2014-01-01

    Theories of embodied cognition argue that language comprehension involves sensory-motor re-enactments of the actions described. However, the degree of specificity of these re-enactments as well as the relationship between action and language remains a matter of debate. Here we investigate these issues by examining how hand-specific information (left or right hand) is recruited in language comprehension and action execution. An fMRI study tested self-reported right-handed participants in two separate tasks that were designed to be as similar as possible to increase sensitivity of the comparison across task: an action execution go/no-go task where participants performed right or left hand actions, and a language task where participants read sentences describing the same left or right handed actions as in the execution task. We found that language-induced activity did not match the hand-specific patterns of activity found for action execution in primary somatosensory and motor cortex, but it overlapped with pre-motor and parietal regions associated with action planning. Within these pre-motor regions, both right hand actions and sentences elicited stronger activity than left hand actions and sentences-a dominant hand effect. Importantly, both dorsal and ventral sections of the left pre-central gyrus were recruited by both tasks, suggesting different action features being recruited. These results suggest that (a) language comprehension elicits motor representations that are hand-specific and akin to multimodal action plans, rather than full action re-enactments; and (b) language comprehension and action execution share schematic hand-specific representations that are richer for the dominant hand, and thus linked to previous motor experience.

  20. Clues from hands/Part 2. Personal details about patients revealed by hand examination.

    PubMed

    Schilli, Karen Danielle; Stricklin, Sherea Monica; Payne, Katie Sue; Rader, Ryan Kent; Stoecker, William V

    2014-01-01

    This is the second part of a two-part article on personal details revealed by hand examination. Examining hands to determine daily activities was the focus of Part 1 in the July/August 2014 Missouri Medicine. Personal traits and preferences, including pets, nutrition and psychology are presented here. These articles serve as a guide for visual clues on the hands to discern a patient's daily activities and personal preference, thereby providing social information that may help establish rapport between patient and physician and may have medical significance.

  1. Prolonged disengagement from distractors near the hands

    PubMed Central

    Vatterott, Daniel B.; Vecera, Shaun P.

    2013-01-01

    Because items near our hands are often more important than items far from our hands, the brain processes visual items near our hands differently than items far from our hands. Multiple experiments have attributed this processing difference to spatial attention, but the exact mechanism behind how spatial attention near our hands changes is still under investigation. The current experiments sought to differentiate between two of the proposed mechanisms: a prioritization of the space near the hands and a prolonged disengagement of spatial attention near the hands. To differentiate between these two accounts, we used the additional singleton paradigm in which observers searched for a shape singleton among homogenously shaped distractors. On half the trials, one of the distractors was a different color. Both the prioritization and disengagement accounts predict differently colored distractors near the hands will slow target responses more than differently colored distractors far from the hands, but the prioritization account also predicts faster responses to targets near the hands than far from the hands. The disengagement account does not make this prediction, because attention does not need to be disengaged when the target appears near the hand. We found support for the disengagement account: Salient distractors near the hands slowed responses more than those far from the hands, yet observers did not respond faster to targets near the hands. PMID:23966971

  2. Efficacy of Waterless Hand Hygiene Compared with Handwashing with Soap: A Field Study in Dar es Salaam, Tanzania

    PubMed Central

    Pickering, Amy J.; Boehm, Alexandria B.; Mwanjali, Mathew; Davis, Jennifer

    2010-01-01

    Effective handwashing with soap requires reliable access to water supplies. However, more than three billion persons do not have household-level access to piped water. This research addresses the challenge of improving hand hygiene within water-constrained environments. The antimicrobial efficacy of alcohol-based hand sanitizer, a waterless hand hygiene product, was evaluated and compared with handwashing with soap and water in field conditions in Dar es Salaam, Tanzania. Hand sanitizer use by mothers resulted in 0.66 and 0.64 log reductions per hand of Escherichia coli and fecal streptococci, respectively. In comparison, handwashing with soap resulted in 0.50 and 0.25 log reductions per hand of E. coli and fecal streptococci, respectively. Hand sanitizer was significantly better than handwashing with respect to reduction in levels of fecal streptococci (P = 0.01). The feasibility and health impacts of promoting hand sanitizer as an alternative hand hygiene option for water-constrained environments should be assessed. PMID:20134005

  3. The hand of Homo naledi

    PubMed Central

    Kivell, Tracy L.; Deane, Andrew S.; Tocheri, Matthew W.; Orr, Caley M.; Schmid, Peter; Hawks, John; Berger, Lee R.; Churchill, Steven E.

    2015-01-01

    A nearly complete right hand of an adult hominin was recovered from the Rising Star cave system, South Africa. Based on associated hominin material, the bones of this hand are attributed to Homo naledi. This hand reveals a long, robust thumb and derived wrist morphology that is shared with Neandertals and modern humans, and considered adaptive for intensified manual manipulation. However, the finger bones are longer and more curved than in most australopiths, indicating frequent use of the hand during life for strong grasping during locomotor climbing and suspension. These markedly curved digits in combination with an otherwise human-like wrist and palm indicate a significant degree of climbing, despite the derived nature of many aspects of the hand and other regions of the postcranial skeleton in H. naledi. PMID:26441219

  4. The hand of Homo naledi.

    PubMed

    Kivell, Tracy L; Deane, Andrew S; Tocheri, Matthew W; Orr, Caley M; Schmid, Peter; Hawks, John; Berger, Lee R; Churchill, Steven E

    2015-10-06

    A nearly complete right hand of an adult hominin was recovered from the Rising Star cave system, South Africa. Based on associated hominin material, the bones of this hand are attributed to Homo naledi. This hand reveals a long, robust thumb and derived wrist morphology that is shared with Neandertals and modern humans, and considered adaptive for intensified manual manipulation. However, the finger bones are longer and more curved than in most australopiths, indicating frequent use of the hand during life for strong grasping during locomotor climbing and suspension. These markedly curved digits in combination with an otherwise human-like wrist and palm indicate a significant degree of climbing, despite the derived nature of many aspects of the hand and other regions of the postcranial skeleton in H. naledi.

  5. Evaluation of the effects of repeated hand washing, sunlight, smoke and dirt on the persistence of deltamethrin on insecticide-treated nets.

    PubMed

    Kayedi, M H; Lines, J D; Haghdoost, A A; Vatandoost, M H; Rassi, Y; Khamisabady, K

    2008-08-01

    Field studies were carried out in Iran to evaluate the effect of various factors (washing, sun, smoke, dust and dirt) on the residual insecticidal activity of PermaNet (a brand of long-lasting insecticidal net), and on nets conventionally treated with deltamethrin (K-O Tab), using bioassay tests. Thirty-two nets were washed five or 15 times, and eight nets were not washed at all. Nets were washed vigorously in cold tap water (17 degrees C, pH 8.9) with a detergent. Hand rubbing continued for 3min. After washing, some nets were exposed to dense smoke from a dung-hay fire for 3min and were also left exposed to the dusty wind between washes. One group of nets was exposed to the sunlight for the full 3-d interval between washes; another was exposed to sunlight for just 3h after each wash; two other groups were kept in the shade. There was a significantly greater loss of activity in nets exposed to the sun throughout the 3-d interval between washes: that is, for a total of 15 to 45 d. However, short sunlight exposure (maximum 3h between washes) during drying did not have any effect. We did not find any significant effect of exposure to dirt, dust and smoke after washing. It is concluded that the effect of sun is much smaller than that of washing, and that drying nets for a few hours in the sun is not harmful.

  6. Delayed norovirus epidemic in the 2009-2010 season in Japan: potential relationship with intensive hand sanitizer use for pandemic influenza.

    PubMed

    Inaida, S; Shobugawa, Y; Matsuno, S; Saito, R; Suzuki, H

    2016-09-01

    Norovirus (NoV) epidemics normally peak in December in Japan; however, the peak in the 2009-2010 season was delayed until the fourth week of January 2010. We suspected intensive hand hygiene that was conducted for a previous pandemic influenza in 2009 as the cause of this delay. We analysed the NoV epidemic trend, based on national surveillance data, and its associations with monthly output data for hand hygiene products, including alcohol-based skin antiseptics and hand soap. The delayed peak in the NoV incidence in the 2009-2010 season had the lowest number of recorded cases of the five seasons studied (2006-2007 to 2010-2011). GII.4 was the most commonly occurring genotype. The monthly relative risk of NoV and monthly output of both alcohol-based skin antiseptics and hand soap were significantly and negatively correlated. Our findings suggest an association between hand hygiene using these products and prevention of NoV transmission.

  7. Hand-to-Hand Model for Bioelectrical Impedance Analysis to Estimate Fat Free Mass in a Healthy Population

    PubMed Central

    Lu, Hsueh-Kuan; Chiang, Li-Ming; Chen, Yu-Yawn; Chuang, Chih-Lin; Chen, Kuen-Tsann; Dwyer, Gregory B.; Hsu, Ying-Lin; Chen, Chun-Hao; Hsieh, Kuen-Chang

    2016-01-01

    This study aimed to establish a hand-to-hand (HH) model for bioelectrical impedance analysis (BIA) fat free mass (FFM) estimation by comparing with a standing position hand-to-foot (HF) BIA model and dual energy X-ray absorptiometry (DXA); we also verified the reliability of the newly developed model. A total of 704 healthy Chinese individuals (403 men and 301 women) participated. FFM (FFMDXA) reference variables were measured using DXA and segmental BIA. Further, regression analysis, Bland–Altman plots, and cross-validation (2/3 participants as the modeling group, 1/3 as the validation group; three turns were repeated for validation grouping) were conducted to compare tests of agreement with FFMDXA reference variables. In male participants, the hand-to-hand BIA model estimation equation was calculated as follows: FFMmHH = 0.537 h2/ZHH − 0.126 year + 0.217 weight + 18.235 (r2 = 0.919, standard estimate of error (SEE) = 2.164 kg, n = 269). The mean validated correlation coefficients and limits of agreement (LOAs) of the Bland–Altman analysis of the calculated values for FFMmHH and FFMDXA were 0.958 and −4.369–4.343 kg, respectively, for hand-to-foot BIA model measurements for men; the FFM (FFMmHF) and FFMDXA were 0.958 and −4.356–4.375 kg, respectively. The hand-to-hand BIA model estimating equation for female participants was FFMFHH = 0.615 h2/ZHH − 0.144 year + 0.132 weight + 16.507 (r2 = 0.870, SEE = 1.884 kg, n = 201); the three mean validated correlation coefficient and LOA for the hand-to-foot BIA model measurements for female participants (FFMFHH and FFMDXA) were 0.929 and −3.880–3.886 kg, respectively. The FFMHF and FFMDXA were 0.942 and −3.511–3.489 kg, respectively. The results of both hand-to-hand and hand-to-foot BIA models demonstrated similar reliability, and the hand-to-hand BIA models are practical for assessing FFM. PMID:27775642

  8. Hand-to-Hand Model for Bioelectrical Impedance Analysis to Estimate Fat Free Mass in a Healthy Population.

    PubMed

    Lu, Hsueh-Kuan; Chiang, Li-Ming; Chen, Yu-Yawn; Chuang, Chih-Lin; Chen, Kuen-Tsann; Dwyer, Gregory B; Hsu, Ying-Lin; Chen, Chun-Hao; Hsieh, Kuen-Chang

    2016-10-21

    This study aimed to establish a hand-to-hand (HH) model for bioelectrical impedance analysis (BIA) fat free mass (FFM) estimation by comparing with a standing position hand-to-foot (HF) BIA model and dual energy X-ray absorptiometry (DXA); we also verified the reliability of the newly developed model. A total of 704 healthy Chinese individuals (403 men and 301 women) participated. FFM (FFM DXA ) reference variables were measured using DXA and segmental BIA. Further, regression analysis, Bland-Altman plots, and cross-validation (2/3 participants as the modeling group, 1/3 as the validation group; three turns were repeated for validation grouping) were conducted to compare tests of agreement with FFM DXA reference variables. In male participants, the hand-to-hand BIA model estimation equation was calculated as follows: FFM m HH = 0.537 h²/Z HH - 0.126 year + 0.217 weight + 18.235 ( r ² = 0.919, standard estimate of error (SEE) = 2.164 kg, n = 269). The mean validated correlation coefficients and limits of agreement (LOAs) of the Bland-Altman analysis of the calculated values for FFM m HH and FFM DXA were 0.958 and -4.369-4.343 kg, respectively, for hand-to-foot BIA model measurements for men; the FFM (FFM m HF ) and FFM DXA were 0.958 and -4.356-4.375 kg, respectively. The hand-to-hand BIA model estimating equation for female participants was FFM F HH = 0.615 h²/Z HH - 0.144 year + 0.132 weight + 16.507 ( r ² = 0.870, SEE = 1.884 kg, n = 201); the three mean validated correlation coefficient and LOA for the hand-to-foot BIA model measurements for female participants (FFM F HH and FFM DXA ) were 0.929 and -3.880-3.886 kg, respectively. The FFM HF and FFM DXA were 0.942 and -3.511-3.489 kg, respectively. The results of both hand-to-hand and hand-to-foot BIA models demonstrated similar reliability, and the hand-to-hand BIA models are practical for assessing FFM.

  9. Hand Leading and Hand Taking Gestures in Autism and Typically Developing Children

    ERIC Educational Resources Information Center

    Gómez, Juan-Carlos

    2015-01-01

    Children with autism use hand taking and hand leading gestures to interact with others. This is traditionally considered to be an example of atypical behaviour illustrating the lack of intersubjective understanding in autism. However the assumption that these gestures are atypical is based upon scarce empirical evidence. In this paper I present…

  10. Prospective, randomized in vivo comparison of a dual-active waterless antiseptic versus two alcohol-only waterless antiseptics for surgical hand antisepsis.

    PubMed

    Olson, Linda K M; Morse, Dan J; Duley, Collette; Savell, Brenon K

    2012-03-01

    This study aimed to demonstrate the value of adding an active level of a persistent antimicrobial agent, such as chlorhexidine gluconate (CHG), to an alcohol-based surgical hand antiseptic. The persistence of 3 waterless, brushless alcohol-based surgical hand antiseptics, including one product containing CHG, was compared. The test products were applied a total of 12 times over 5 days. Samples of aerobic bacteria were collected on days 1 and 5, on both days immediately after drying and 6 hours later, using the glove juice technique. Relative suppression of regrowth was compared using t tests. Using an equivalence margin of 20%, the alcohol plus CHG product showed noninferiority to the alcohol-only products at all sampling points and, based on significantly lower bacterial regrowth (P = .026), superior persistence to the alcohol-only products after 6 hours of glove wear. Given the primary objective of surgical hand antisepsis of reducing resident skin flora for the duration of the surgical procedure, using an alcohol-based hand antiseptic containing CHG appears to be the most appropriate choice for maintaining microbial levels as low as possible for as long as possible. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  11. Hand controller commonality evaluation process

    NASA Technical Reports Server (NTRS)

    Stuart, Mark A.; Bierschwale, John M.; Wilmington, Robert P.; Adam, Susan C.; Diaz, Manuel F.; Jensen, Dean G.

    1990-01-01

    A hand controller evaluation process has been developed to determine the appropriate hand controller configurations for supporting remotely controlled devices. These devices include remote manipulator systems (RMS), dexterous robots, and remotely-piloted free flyers. Standard interfaces were developed to evaluate six different hand controllers in three test facilities including dynamic computer simulations, kinematic computer simulations, and physical simulations. The hand controllers under consideration were six degree-of-freedom (DOF) position and rate minimaster and joystick controllers, and three-DOF rate controllers. Task performance data, subjective comments, and anthropometric data obtained during tests were used for controller configuration recommendations to the SSF Program.

  12. Recognizing the Operating Hand and the Hand-Changing Process for User Interface Adjustment on Smartphones †

    PubMed Central

    Guo, Hansong; Huang, He; Huang, Liusheng; Sun, Yu-E

    2016-01-01

    As the size of smartphone touchscreens has become larger and larger in recent years, operability with a single hand is getting worse, especially for female users. We envision that user experience can be significantly improved if smartphones are able to recognize the current operating hand, detect the hand-changing process and then adjust the user interfaces subsequently. In this paper, we proposed, implemented and evaluated two novel systems. The first one leverages the user-generated touchscreen traces to recognize the current operating hand, and the second one utilizes the accelerometer and gyroscope data of all kinds of activities in the user’s daily life to detect the hand-changing process. These two systems are based on two supervised classifiers constructed from a series of refined touchscreen trace, accelerometer and gyroscope features. As opposed to existing solutions that all require users to select the current operating hand or confirm the hand-changing process manually, our systems follow much more convenient and practical methods and allow users to change the operating hand frequently without any harm to the user experience. We conduct extensive experiments on Samsung Galaxy S4 smartphones, and the evaluation results demonstrate that our proposed systems can recognize the current operating hand and detect the hand-changing process with 94.1% and 93.9% precision and 94.1% and 93.7% True Positive Rates (TPR) respectively, when deciding with a single touchscreen trace or accelerometer-gyroscope data segment, and the False Positive Rates (FPR) are as low as 2.6% and 0.7% accordingly. These two systems can either work completely independently and achieve pretty high accuracies or work jointly to further improve the recognition accuracy. PMID:27556461

  13. “The 3/3 Strategy”: A Successful Multifaceted Hospital Wide Hand Hygiene Intervention Based on WHO and Continuous Quality Improvement Methodology

    PubMed Central

    Mestre, Gabriel; Berbel, Cristina; Tortajada, Purificación; Alarcia, Margarita; Coca, Roser; Gallemi, Gema; Garcia, Irene; Fernández, Mari Mar; Aguilar, Mari Carmen; Martínez, José Antonio; Rodríguez-Baño, Jesús

    2012-01-01

    Background Only multifaceted hospital wide interventions have been successful in achieving sustained improvements in hand hygiene (HH) compliance. Methodology/Principal Findings Pre-post intervention study of HH performance at baseline (October 2007– December 2009) and during intervention, which included two phases. Phase 1 (2010) included multimodal WHO approach. Phase 2 (2011) added Continuous Quality Improvement (CQI) tools and was based on: a) Increase of alcohol hand rub (AHR) solution placement (from 0.57 dispensers/bed to 1.56); b) Increase in frequency of audits (three days every three weeks: “3/3 strategy”); c) Implementation of a standardized register form of HH corrective actions; d) Statistical Process Control (SPC) as time series analysis methodology through appropriate control charts. During the intervention period we performed 819 scheduled direct observation audits which provided data from 11,714 HH opportunities. The most remarkable findings were: a) significant improvements in HH compliance with respect to baseline (25% mean increase); b) sustained high level (82%) of HH compliance during intervention; c) significant increase in AHRs consumption over time; c) significant decrease in the rate of healthcare-acquired MRSA; d) small but significant improvements in HH compliance when comparing phase 2 to phase 1 [79.5% (95% CI: 78.2–80.7) vs 84.6% (95% CI:83.8–85.4), p<0.05]; e) successful use of control charts to identify significant negative and positive deviations (special causes) related to the HH compliance process over time (“positive”: 90.1% as highest HH compliance coinciding with the “World hygiene day”; and “negative”:73.7% as lowest HH compliance coinciding with a statutory lay-off proceeding). Conclusions/Significance CQI tools may be a key addition to WHO strategy to maintain a good HH performance over time. In addition, SPC has shown to be a powerful methodology to detect special causes in HH performance (positive

  14. The effect of perineal control with hands-on and hand-poised methods on perineal trauma and delivery outcome

    PubMed Central

    Foroughipour, Azam; Firuzeh, Farah; Ghahiri, Ataolah; Norbakhsh, Vajihe; Heidari, Tayebeh

    2011-01-01

    BACKGROUND: The objective of the present study was to evaluate the effect of the two methods of delivery, “hands-on” vs. “hands poised”, on perineal trauma and delivery outcome in primiparous women referred to Shariati Hospital of Isfahan during 2007-2008. METHODS: In a clinical trial study, 100 low risk primiparous pregnant women were randomly assigned to two hands-on and hand-poised (hands-off) groups. In the hands-on group, this method was used to control fetal head in the second stage of labor. It means that the fingers of one hand supported fetal occiput and the other hand applied slight pressure on the head to control the delivery of the head during the crowning process. In the hands-poised group, midwife observed the parturient woman and do not touch perineum during the second labor stage while fetal head was delivering. Then, the two groups were compared in terms of perineal trauma, as well as neonatal and delivery outcome. RESULTS: Demographic characteristics of all studied women were similar in two groups. The rate of episiotomy was higher in hands-on group (84% vs. 40%, p = 0.001). The rate of postpartum hemorrhage (4th stage) was higher in hands-on group (12% vs. 4%, p = 0.04). The rate of mild and moderate postpartum pain in hands-on group was higher than hands-off group (70% vs. 58% and 29% vs. 10%, p < 0.001) but sever pain was not different in two groups. CONCLUSIONS: It seems that hands-poised method is associated with less perineal trauma, particularly regarding the lower need for episiotomy and postpartum hemorrhage. PMID:22279480

  15. [The surgeon as a hand patient: the clinical and psychological impact of hand and wrist fractures].

    PubMed

    Chin, K R; Lonner, J H; Jupiter, B S; Jupiter, J B

    2010-03-01

    To gain insight into the management of patients with hand and wrist injuries, a series of clinical and psychological analyses was performed on 9 surgeons, each of whom underwent operative fixation of a hand or wrist fracture. The results of these analyses suggest that the functional outcome after hand surgery was affected by the surgeons' personality, motivation, and ability to accept and adapt to the injury, the nature of the injury, and the importance of the hand to the surgeons' careers. Surgeons are highly motivated and compulsive individuals who consider their career involvement a major source of identity and self-worth. Most returned to their operative duties ahead of the schedule set by their hand surgeons (average, 25 days after surgery), regarded their injuries as a positive challenge, and changed their lifestyles after injury to protect their hands.

  16. Robotic hand with locking mechanism using TCP muscles for applications in prosthetic hand and humanoids

    NASA Astrophysics Data System (ADS)

    Saharan, Lokesh; Tadesse, Yonas

    2016-04-01

    This paper presents a biomimetic, lightweight, 3D printed and customizable robotic hand with locking mechanism consisting of Twisted and Coiled Polymer (TCP) muscles based on nylon precursor fibers as artificial muscles. Previously, we have presented a small-sized biomimetic hand using nylon based artificial muscles and fishing line muscles as actuators. The current study focuses on an adult-sized prosthetic hand with improved design and a position/force locking system. Energy efficiency is always a matter of concern to make compact, lightweight, durable and cost effective devices. In natural human hand, if we keep holding objects for long time, we get tired because of continuous use of energy for keeping the fingers in certain positions. Similarly, in prosthetic hands we also need to provide energy continuously to artificial muscles to hold the object for a certain period of time, which is certainly not energy efficient. In this work we, describe the design of the robotic hand and locking mechanism along with the experimental results on the performance of the locking mechanism.

  17. Equipment & New Products.

    ERIC Educational Resources Information Center

    Poitras, Adrian W., Ed.

    1979-01-01

    Reviews new science equipment and products for the laboratory. Includes hand-held calculators, fiberglass fume hoods, motorized microtomy, disposable mouse cages, and electric timers. Describes 11 products total. Provides manufacturer name, address, and price. (MA)

  18. "Like the palm of my hands": Motor imagery enhances implicit and explicit visual recognition of one's own hands.

    PubMed

    Conson, Massimiliano; Volpicella, Francesco; De Bellis, Francesco; Orefice, Agnese; Trojano, Luigi

    2017-10-01

    A key point in motor imagery literature is that judging hands in palm view recruits sensory-motor information to a higher extent than judging hands in back view, due to the greater biomechanical complexity implied in rotating hands depicted from palm than from back. We took advantage from this solid evidence to test the nature of a phenomenon known as self-advantage, i.e. the advantage in implicitly recognizing self vs. others' hand images. The self-advantage has been actually found when implicitly but not explicitly judging self-hands, likely due to dissociation between implicit and explicit body representations. However, such a finding might be related to the extent to which motor imagery is recruited during implicit and explicit processing of hand images. We tested this hypothesis in two behavioural experiments. In Experiment 1, right-handed participants judged laterality of either self or others' hands, whereas in Experiment 2, an explicit recognition of one's own hands was required. Crucially, in both experiments participants were randomly presented with hand images viewed from back or from palm. The main result of both experiments was the self-advantage when participants judged hands from palm view. This novel finding demonstrate that increasing the "motor imagery load" during processing of self vs. others' hands can elicit a self-advantage in explicit recognition tasks as well. Future studies testing the possible dissociation between implicit and explicit visual body representations should take into account the modulatory effect of motor imagery load on self-hand processing. Copyright © 2017. Published by Elsevier B.V.

  19. Effects of Temperature on Sound Production and Auditory Abilities in the Striped Raphael Catfish Platydoras armatulus (Family Doradidae)

    PubMed Central

    Papes, Sandra; Ladich, Friedrich

    2011-01-01

    Background Sound production and hearing sensitivity of ectothermic animals are affected by the ambient temperature. This is the first study investigating the influence of temperature on both sound production and on hearing abilities in a fish species, namely the neotropical Striped Raphael catfish Platydoras armatulus. Methodology/Principal Findings Doradid catfishes produce stridulation sounds by rubbing the pectoral spines in the shoulder girdle and drumming sounds by an elastic spring mechanism which vibrates the swimbladder. Eight fish were acclimated for at least three weeks to 22°, then to 30° and again to 22°C. Sounds were recorded in distress situations when fish were hand-held. The stridulation sounds became shorter at the higher temperature, whereas pulse number, maximum pulse period and sound pressure level did not change with temperature. The dominant frequency increased when the temperature was raised to 30°C and the minimum pulse period became longer when the temperature decreased again. The fundamental frequency of drumming sounds increased at the higher temperature. Using the auditory evoked potential (AEP) recording technique, the hearing thresholds were tested at six different frequencies from 0.1 to 4 kHz. The temporal resolution was determined by analyzing the minimum resolvable click period (0.3–5 ms). The hearing sensitivity was higher at the higher temperature and differences were more pronounced at higher frequencies. In general, latencies of AEPs in response to single clicks became shorter at the higher temperature, whereas temporal resolution in response to double-clicks did not change. Conclusions/Significance These data indicate that sound characteristics as well as hearing abilities are affected by temperatures in fishes. Constraints imposed on hearing sensitivity at different temperatures cannot be compensated even by longer acclimation periods. These changes in sound production and detection suggest that acoustic orientation and

  20. The Plastic Surgery Hand Curriculum.

    PubMed

    Silvestre, Jason; Levin, L Scott; Serletti, Joseph M; Chang, Benjamin

    2015-12-01

    Designing an effective hand rotation for plastic surgery residents is difficult. The authors address this limitation by elucidating the critical components of the hand curriculum during plastic surgery residency. Hand questions on the Plastic Surgery In-Service Training Exam for six consecutive years (2008 to 2013) were characterized by presence of imaging, vignette setting, question taxonomy, answer domain, anatomy, and topic. Answer references were quantified by source and year of publication. Two hundred sixty-six questions were related to hand surgery (22.7 percent of all questions; 44.3 per year) and 61 were accompanied by an image (22.9 percent). Vignettes tended to be clinic- (50.0 percent) and emergency room-based (35.3 percent) (p < 0.001). Questions required decision-making (60.5 percent) over interpretation (25.9 percent) and recall skills (13.5 percent) (p < 0.001). Answers focused on interventions (57.5 percent) over anatomy/pathology (25.2 percent) and diagnoses (17.3 percent) (p < 0.001). Nearly half of the questions focused on the digits. The highest yield topics were trauma (35.3 percent), reconstruction (24.4 percent), and aesthetic and functional problems (14.2 percent). The Journal of Hand Surgery (American volume) (20.5 percent) and Plastic and Reconstructive Surgery (18.0 percent) were the most-cited journals, and the median publication lag was 7 years. Green's Operative Hand Surgery was the most-referenced textbook (41.8 percent). These results will enable trainees to study hand surgery topics with greater efficiency. Faculty can use these results to ensure that tested topics are covered during residency training. Thus, a benchmark is established to improve didactic, clinical, and operative experiences in hand surgery.

  1. Hand Grasping Synergies As Biometrics.

    PubMed

    Patel, Vrajeshri; Thukral, Poojita; Burns, Martin K; Florescu, Ionut; Chandramouli, Rajarathnam; Vinjamuri, Ramana

    2017-01-01

    Recently, the need for more secure identity verification systems has driven researchers to explore other sources of biometrics. This includes iris patterns, palm print, hand geometry, facial recognition, and movement patterns (hand motion, gait, and eye movements). Identity verification systems may benefit from the complexity of human movement that integrates multiple levels of control (neural, muscular, and kinematic). Using principal component analysis, we extracted spatiotemporal hand synergies (movement synergies) from an object grasping dataset to explore their use as a potential biometric. These movement synergies are in the form of joint angular velocity profiles of 10 joints. We explored the effect of joint type, digit, number of objects, and grasp type. In its best configuration, movement synergies achieved an equal error rate of 8.19%. While movement synergies can be integrated into an identity verification system with motion capture ability, we also explored a camera-ready version of hand synergies-postural synergies. In this proof of concept system, postural synergies performed well, but only when specific postures were chosen. Based on these results, hand synergies show promise as a potential biometric that can be combined with other hand-based biometrics for improved security.

  2. Hand Grasping Synergies As Biometrics

    PubMed Central

    Patel, Vrajeshri; Thukral, Poojita; Burns, Martin K.; Florescu, Ionut; Chandramouli, Rajarathnam; Vinjamuri, Ramana

    2017-01-01

    Recently, the need for more secure identity verification systems has driven researchers to explore other sources of biometrics. This includes iris patterns, palm print, hand geometry, facial recognition, and movement patterns (hand motion, gait, and eye movements). Identity verification systems may benefit from the complexity of human movement that integrates multiple levels of control (neural, muscular, and kinematic). Using principal component analysis, we extracted spatiotemporal hand synergies (movement synergies) from an object grasping dataset to explore their use as a potential biometric. These movement synergies are in the form of joint angular velocity profiles of 10 joints. We explored the effect of joint type, digit, number of objects, and grasp type. In its best configuration, movement synergies achieved an equal error rate of 8.19%. While movement synergies can be integrated into an identity verification system with motion capture ability, we also explored a camera-ready version of hand synergies—postural synergies. In this proof of concept system, postural synergies performed well, but only when specific postures were chosen. Based on these results, hand synergies show promise as a potential biometric that can be combined with other hand-based biometrics for improved security. PMID:28512630

  3. Effectiveness of Hand Sanitizers with and without Organic Acids for Removal of Rhinovirus from Hands

    PubMed Central

    Turner, Ronald B.; Fuls, Janice L.; Rodgers, Nancy D.

    2010-01-01

    These studies evaluated the effectiveness of ethanol hand sanitizers with or without organic acids to remove detectable rhinovirus from the hands and prevent experimental rhinovirus infection. Ethanol hand sanitizers were significantly more effective than hand washing with soap and water. The addition of organic acids to the ethanol provided residual virucidal activity that persisted for at least 4 h. Whether these treatments will reduce rhinovirus infection in the natural setting remains to be determined. PMID:20047916

  4. 3D Printed Robotic Hand

    NASA Technical Reports Server (NTRS)

    Pizarro, Yaritzmar Rosario; Schuler, Jason M.; Lippitt, Thomas C.

    2013-01-01

    Dexterous robotic hands are changing the way robots and humans interact and use common tools. Unfortunately, the complexity of the joints and actuations drive up the manufacturing cost. Some cutting edge and commercially available rapid prototyping machines now have the ability to print multiple materials and even combine these materials in the same job. A 3D model of a robotic hand was designed using Creo Parametric 2.0. Combining "hard" and "soft" materials, the model was printed on the Object Connex350 3D printer with the purpose of resembling as much as possible the human appearance and mobility of a real hand while needing no assembly. After printing the prototype, strings where installed as actuators to test mobility. Based on printing materials, the manufacturing cost of the hand was $167, significantly lower than other robotic hands without the actuators since they have more complex assembly processes.

  5. [Cleanliness in the operating room].

    PubMed

    Suzuki, Toshiyasu

    2010-05-01

    With regard to recent findings in the cleanliness of the operating room, concerning handwashing and performing operations, the traditional method of excessive scrubbing using a brush is not effective, and handwashing using only an alcohol-containing antiseptic hand rub (rubbing method) has become common practice. Use of a brush has already been abolished in some medical institutions. In addition, sterilized water used for handwashing when performing operations has no scientific basis and use of tap water is considered sufficient. Furthermore, the concept of operating room zoning has also undergone a dramatic change. It was discovered that a layout focusing on work efficiency is more desirable than the one that follows an excessively rigid zoning pattern. One-footwear System not requiring change of shoes also has various advantages in improving the efficiency of the operation room, and this is thought to become commonplace in the future.

  6. Hand washing for preventing diarrhoea.

    PubMed

    Ejemot, R I; Ehiri, J E; Meremikwu, M M; Critchley, J A

    2008-01-23

    Diarrhoea is a common cause of morbidity and a leading cause of death among children aged less than five years, particularly in low- and middle-income countries. It is transmitted by ingesting contaminated food or drink, by direct person-to-person contact, or from contaminated hands. Hand washing is one of a range of hygiene promotion interventions that can interrupt the transmission of diarrhoea-causing pathogens. To evaluate the effects of interventions to promote hand washing on diarrhoeal episodes in children and adults. In May 2007, we searched the Cochrane Infectious Diseases Group Specialized Register, CENTRAL (The Cochrane Library 2007, Issue 2), MEDLINE, EMBASE, LILACS, PsycINFO, Science Citation Index and Social Science Citation Index, ERIC (1966 to May 2007), SPECTR, Bibliomap, RoRe, The Grey Literature, and reference lists of articles. We also contacted researchers and organizations in the field. Randomized controlled trials, where the unit of randomization is an institution (eg day-care centre), household, or community, that compared interventions to promote hand washing or a hygiene promotion that included hand washing with no intervention to promote hand washing. Two authors independently assessed trial eligibility and methodological quality. Where appropriate, incidence rate ratios (IRR) were pooled using the generic inverse variance method and random-effects model with 95% confidence intervals (CI). Fourteen randomized controlled trials met the inclusion criteria. Eight trials were institution-based, five were community-based, and one was in a high-risk group (AIDS patients). Interventions promoting hand washing resulted in a 29% reduction in diarrhoea episodes in institutions in high-income countries (IRR 0.71, 95% CI 0.60 to 0.84; 7 trials) and a 31% reduction in such episodes in communities in low- or middle-income countries (IRR 0.69, 95% CI 0.55 to 0.87; 5 trials). Hand washing can reduce diarrhoea episodes by about 30%. This significant

  7. Relationship between output from MIDI-keyboard playing and hand function assessments on affected hand after stroke.

    PubMed

    Chong, Hyun Ju; Han, Soo Jeong; Kim, Yong Jae; Park, Hye Young; Kim, Soo Ji

    2014-01-01

    While a number of studies have tested the therapeutic effectiveness of playing musical instruments, such as the electronic keyboard using Musical Instrument Digital Interface (MIDI), it is still unclear whether outcomes of electronic keyboard playing are related to hand function tests. The purpose of this study was to investigate the correlation between MIDI-keyboard playing and hand function tests, including grip strength, Box and Block test (BBT), and Jensen-Taylor Hand Function Test (JTHF). A total of 66 stroke patients were recruited from medical centers and were classified into acute (n = 21), subacute (n = 28), and chronic (n = 17) recovery stages. The participants' mean age was 60.5 years. The MIDI-keyboard playing protocol based on sequential key pressing was implemented. All hand function tests were performed by certified occupational therapists. MIDI scores from participants at all three recovery stages were significantly correlated with BBT and grip strength. Overall, MIDI-keyboard playing scores demonstrated moderate to high correlations with hand function tests except for participants at the chronic stage and the JTHF, which showed no correlation. These findings suggest that MIDI-keyboard playing has great potential as an assessment tool of hand function, especially hand dexterity in acute and subacute stroke patients. Further studies are needed to refine the specific keyboard playing tasks that increase responsiveness to traditional hand function tests.

  8. Division of Labor in Hand Usage Is Associated with Higher Hand Performance in Free-Ranging Bonnet Macaques, Macaca radiata

    PubMed Central

    Mangalam, Madhur; Desai, Nisarg; Singh, Mewa

    2015-01-01

    A practical approach to understanding lateral asymmetries in body, brain, and cognition would be to examine the performance advantages/disadvantages associated with the corresponding functions and behavior. In the present study, we examined whether the division of labor in hand usage, marked by the preferential usage of the two hands across manual operations requiring maneuvering in three-dimensional space (e.g., reaching for food, grooming, and hitting an opponent) and those requiring physical strength (e.g., climbing), is associated with higher hand performance in free-ranging bonnet macaques, Macaca radiata. We determined the extent to which the macaques exhibit laterality in hand usage in an experimental unimanual and a bimanual food-reaching task, and the extent to which manual laterality is associated with hand performance in an experimental hand-performance-differentiation task. We observed negative relationships between (a) the latency in food extraction by the preferred hand in the hand-performance-differentiation task (wherein, lower latency implies higher performance), the preferred hand determined using the bimanual food-reaching task, and the normalized difference between the performance of the two hands, and (b) the normalized difference between the performance of the two hands and the absolute difference between the laterality in hand usage in the unimanual and the bimanual food-reaching tasks (wherein, lesser difference implies higher manual specialization). Collectively, these observations demonstrate that the division of labor between the two hands is associated with higher hand performance. PMID:25806511

  9. [Hand motor dysfunctions in computer users].

    PubMed

    Shavlovskaia, O A; Shvarkov, S B; Posokhov, S I

    2010-01-01

    It were studied 239 female typists aged from 16 to 62 years (mean age 20,1±7,8 years) using author's questionnaire for computer typists to assess hand function and develop preventive measures of disturbances revealed. Indirect signs of tunnel hand neuropathy (27,2%), focal hand dystonia (21,4%) and muscular-tonic syndromes of different localization (18%) have been found. Typists are a risk group of fine hand motor dysfunctions. As preventive measures, authors recommend to use computer auxiliary devices, to change a motor stereotype during the day, to make hand "motor holidays", to organize working place.

  10. Unilateral Cleft Hand with Cleft Foot

    PubMed Central

    Baba, Asif Nazir; Bhat, Yasmeen J.; Ahmed, Sheikh Mushtaq; Nazir, Abid

    2009-01-01

    Congenital anomalies of the hand form an important class of congenital malformations. They have a huge functional importance because of the part played by the hand in the daily activities of a person. The deformities also have significant cosmetic significance and may also be associated with other anomalies. Amongst the congenital anomalies, central deficiency or cleft hand is relatively rare. The association of cleft foot with cleft hand is an even more rare occurance. We present a case report of a 6 year old child, born of a non-consanginous marriage, having congenital central deficiency of ipsilateral hand and foot. PMID:21475543

  11. The All-in-One Human Resource Policy of Taiwan's Hand-in-Hand Program

    ERIC Educational Resources Information Center

    Ho, Hsuan-fu; Lin, Liang-Ching

    2012-01-01

    The Taiwan Government launched the Hand-in-Hand After-School Care Program in 2006 with several goals: In addition to providing disadvantaged students with supplemental learning opportunities, this highly ambitious government program hopes to provide increased employment opportunities for substitute teachers and low-income college students, and…

  12. Managing Productivity.

    DTIC Science & Technology

    1985-01-01

    could be a small construction , management firm, where project managers keep track of all phases and evolutions of contracts by hand. An obvious polution ...overview of productivity measurement. This idea can be expanded much further with the concept of productivity audits . Productivity auditing is a...comprehensive procedure, not unlike traditional audit practices which monitors and evaluates organizational practices to determine whether functional units

  13. An Unusual Inverted Saline Microbial Mat Community in an Interdune Sabkha in the Rub' al Khali (the Empty Quarter), United Arab Emirates

    PubMed Central

    McKay, Christopher P.; Rask, Jon C.; Detweiler, Angela M.; Bebout, Brad M.; Everroad, R. Craig; Lee, Jackson Z.; Chanton, Jeffrey P.; Mayer, Marisa H.; Caraballo, Adrian A. L.; Kapili, Bennett; Al-Awar, Meshgan; Al-Farraj, Asma

    2016-01-01

    Salt flats (sabkha) are a recognized habitat for microbial life in desert environments and as analogs of habitats for possible life on Mars. Here we report on the physical setting and microbiology of interdune sabkhas among the large dunes in the Rub' al Khali (the Empty Quarter) in Liwa Oasis, United Arab Emirates. The salt flats, composed of gypsum and halite, are moistened by relatively fresh ground water. The result is a salinity gradient that is inverted compared to most salt flat communities with the hypersaline layer at the top and freshwater layers below. We describe and characterize a rich photosynthetically-based microbial ecosystem that is protected from the arid outside environment by a translucent salt crust. Gases collected from sediments under shallow ponds in the sabkha contain methane in concentrations as high as 3400 ppm. The salt crust could preserve biomarkers and other evidence for life in the salt after it dries out. Chloride-filled depressions have been identified on Mars and although surface flow of water is unlikely on Mars today, ground water is possible. Such a near surface system with modern groundwater flowing under ancient salt deposits could be present on Mars and could be accessed by surface rovers. PMID:26982497

  14. A new approach to hand-based authentication

    NASA Astrophysics Data System (ADS)

    Amayeh, G.; Bebis, G.; Erol, A.; Nicolescu, M.

    2007-04-01

    Hand-based authentication is a key biometric technology with a wide range of potential applications both in industry and government. Traditionally, hand-based authentication is performed by extracting information from the whole hand. To account for hand and finger motion, guidance pegs are employed to fix the position and orientation of the hand. In this paper, we consider a component-based approach to hand-based verification. Our objective is to investigate the discrimination power of different parts of the hand in order to develop a simpler, faster, and possibly more accurate and robust verification system. Specifically, we propose a new approach which decomposes the hand in different regions, corresponding to the fingers and the back of the palm, and performs verification using information from certain parts of the hand only. Our approach operates on 2D images acquired by placing the hand on a flat lighting table. Using a part-based representation of the hand allows the system to compensate for hand and finger motion without using any guidance pegs. To decompose the hand in different regions, we use a robust methodology based on morphological operators which does not require detecting any landmark points on the hand. To capture the geometry of the back of the palm and the fingers in suffcient detail, we employ high-order Zernike moments which are computed using an effcient methodology. The proposed approach has been evaluated on a database of 100 subjects with 10 images per subject, illustrating promising performance. Comparisons with related approaches using the whole hand for verification illustrate the superiority of the proposed approach. Moreover, qualitative comparisons with state-of-the-art approaches indicate that the proposed approach has comparable or better performance.

  15. Hands-on Simulation versus Traditional Video-learning in Teaching Microsurgery Technique

    PubMed Central

    SAKAMOTO, Yusuke; OKAMOTO, Sho; SHIMIZU, Kenzo; ARAKI, Yoshio; HIRAKAWA, Akihiro; WAKABAYASHI, Toshihiko

    2017-01-01

    Bench model hands-on learning may be more effective than traditional didactic practice in some surgical fields. However, this has not been reported for microsurgery. Our study objective was to demonstrate the efficacy of bench model hands-on learning in acquiring microsuturing skills. The secondary objective was to evaluate the aptitude for microsurgery based on personality assessment. Eighty-six medical students comprising 62 men and 24 women were randomly assigned to either 20 min of hands-on learning with a bench model simulator or 20 min of video-learning using an instructional video. They then practiced microsuturing for 40 min. Each student then made three knots, and the time to complete the task was recorded. The final products were scored by two independent graders in a blind fashion. All participants then took a personality test, and their microsuture test scores and the time to complete the task were compared. The time to complete the task was significantly shorter in the simulator group than in the video-learning group. The final product scores tended to be higher with simulator-learning than with video-learning, but the difference was not significant. Students with high “extraversion” scores on the personality inventory took a shorter time to complete the suturing test. Simulator-learning was more effective for microsurgery training than video instruction, especially in understanding the procedure. There was a weak association between personality traits and microsurgery skill. PMID:28381653

  16. Cued Dichotic Listening with Right-Handed, Left-Handed, Bilingual and Learning-Disabled Children.

    ERIC Educational Resources Information Center

    Obrzut, John E.; And Others

    This study used cued dichotic listening to investigate differences in language lateralization among right-handed (control), left handed, bilingual, and learning disabled children. Subjects (N=60) ranging in age from 7-13 years were administered a consonant-vowel-consonant dichotic paradigm with three experimental conditions (free recall, directed…

  17. Do the hands talk on mind's behalf? Differences in language ability between left- and right-handed children.

    PubMed

    Natsopoulos, D; Kiosseoglou, G; Xeromeritou, A; Alevriadou, A

    1998-09-01

    Two hundred seventy children of school age, 135 of whom were left-handed and an equivalent number of whom were right-handed, have been examined in the present study using a test battery of nine language ability measures: Vocabulary, Similarities, Comprehension (WISC-R), Deductive Reasoning, Inductive Reasoning, Sentence Completion, Comprehension of Sentential Semantics, Comprehension of Syntax, and Text Processing. The data analysis has indicated that: (1) One-factor solution applies both to the right- and left-handed population according to Standard Error Scree Method (Zoski & Jurs, 1996) with regard to language ability measures. (2) Handedness discriminates between right-handers (superior) and left-handers (inferior) in language ability. (3) There have been subgroups of left-handed children who differ in language ability distribution compared with right-handed children according to Hierarchical Cluster Analysis. (4) Extreme versus mild bias to hand preference and hand skill do not differentiate performance subgroups neither within the left-handed nor within the right-handed main group. (5) Sex and familial sinistrality do not affect performance. The results are discussed in relation to (a) "human balanced polymorphism" theory advocated by Annett (mainly Annett, 1985, 1993a; Annett & Manning, 1989), (b) potential pathology (mainly Bishop, 1984, 1990a; Coren & Halpern, 1991; Satz, Orsini, Saslow & Henry, 1985) and "developmental instability" (Yeo, Gangestad & Daniel, 1993), and delay of left-hemisphere maturation in left-handed individuals (Geschwind & Galaburda, 1985a,b, 1987), by pointing out the strength and weaknesses of these theoretical approaches in accounting for the present data. Copyright 1998 Academic Press.

  18. Left-handed skeletally mature baseball players have smaller humeral retroversion in the throwing arm than right-handed players.

    PubMed

    Takenaga, Tetsuya; Goto, Hideyuki; Sugimoto, Katsumasa; Tsuchiya, Atsushi; Fukuyoshi, Masaki; Nakagawa, Hiroki; Nozaki, Masahiro; Takeuchi, Satoshi; Otsuka, Takanobu

    2017-12-01

    It is known that the humeral retroversion of baseball players is greater in the throwing arm than in the nonthrowing arm. An investigation measuring dry bone specimens also showed that the right humerus had greater retroversion than the left. Considering these facts, it was hypothesized that humeral retroversion would differ between right- and left-handed players. This study aimed to compare the bilateral humeral retroversion between right- and left-handed skeletally mature baseball players. We investigated 260 (196 right-handed and 64 left-handed) male baseball players who belonged to a college or amateur team. Bilateral humeral retroversion was assessed using an ultrasound-assisted technique (humeral torsion angle [HTA]) as described by previous studies. Analysis of covariance, adjusted for handedness and baseball position, assessed the effect of throwing arm dominance on HTA. In comparison of the throwing arm, HTA was significantly smaller in left-handed (left humerus) than in right-handed (right humerus) players (77° vs. 81°; P < .001). In comparison of the nonthrowing arm, HTA was significantly greater in left-handed (right humerus) than in right-handed (left humerus) players (73° vs. 69°; P < .001). The mean side-to-side difference of HTA was significantly smaller in left-handed than in right-handed players (3° vs. 12°; P < .001). Humeral retroversion of left-handed skeletally mature baseball players was significantly smaller in the throwing arm, greater in the nonthrowing arm, and smaller in side-to-side differences than that of right-handed players. These findings may be key to understanding some of the biomechanical differences between right- and left-handed baseball players. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. The Kinematics of Trunk and Upper Extremities in One-Handed and Two-Handed Backhand Stroke

    PubMed Central

    Stępień, Adam; Bober, Tadeusz; Zawadzki, Jerzy

    2011-01-01

    The aim of this study was to present kinematics of trunk and upper extremities in tennis players who perform one-handed and two-handed backhand strokes. The study aimed to address the question of whether one of those techniques has some important advantage over the other. If so, what makes it superior? The study included 10 tennis coaches with average coaching experience of 9 years. The coaches were asked to hit 15 one-handed and two-handed backhands. The tests were carried out in a laboratory. A sponge ball was used in order to protect the measurement equipment. Video motion analysis was carried out using BTS SMART system; images were recorded with 6 cameras with a rate of 120 frames per second. The analysis of both backhand strokes focused on the second phase of the stroke (acceleration). The use of an eight-element model of human body for description of upper body motion in both techniques revealed kinematic differences in how both backhands are performed. The two-handed backhand was performed in closed kinetic chain with 8 degrees of freedom, whereas the one-handed backhand involved an open kinetic chain with 7 degrees of freedom. Higher rigidity of upper extremities which are connected with trunk in the two-handed backhand, contributes to an elevated trunk effect in this stroke. This is confirmed by higher component velocities for racket handle, which result from trunk rotation in the two-handed backhand and a negative separation angle in the two-handed backhand at the moment of contact of the racket with the ball. The study does not provide a clear-cut answer to the question of advantages of one technique over the other; however, it reveals dissimilar patterns of driving the racket in both techniques, which suggests the need for extending the analysis of techniques of both backhands with additional kinematics of tennis racket in consideration of measurements of ball velocities. PMID:23486650

  20. Evaluation of a functional hand orthosis combined with electrical stimulation adjunct to arm-hand rehabilitation in subacute stroke patients with a severely to moderately affected hand function.

    PubMed

    Franck, Johan Anton; Smeets, Rob Johannes Elise Marie; Seelen, Henk Alexander Maria

    2018-01-09

    To investigate the usability and effectiveness of a functional hand orthosis, combined with electrical stimulation adjunct to therapy-as-usual, on functional use of the moderately/severely impaired hand in sub-acute stroke patients. Single case experiment (A-B-A'-design) involving eight sub-acute stroke patients. The functional hand orthosis and electrical stimulation were used for six weeks, four days/week, 45'/day. Action_Research_Arm_Test, Intrinsic_Motivation_Inventory. At group level, patients improved 19.2 points (median value) (interquartile range: [8.8, 29.5] points) on the Action_Research_Arm_Test (p = 0.001). After correcting for spontaneous recovery and/or therapy-as-usual effects Action_Research_Arm_Test scores still improved significantly (median: 17.2 points; interquartile range: [5.1, 29.2] points) (p = 0.002). At individual level, six patients had improved as to arm-hand skill performance at follow-up (p < = 0.010). In one patient, arm-hand skill performance improvement did not attain statistical significance. In another patient, no arm-hand skill performance improvement was observed. Average Intrinsic_Motivation_Inventory sub-scores were between 4.6 and 6.3 (maximum: 7), except for 'perceived pressure/tension' (3.3). Sub-acute stroke patients who display only little/modest improvement on their capacity to perform daily activities, seem to benefit from training with a dynamic arm orthosis in combination with electrical stimulation. Patients' perceived intrinsic motivation and sense of self-regulation was high. Implications for rehabilitation Arm-hand training featuring the dynamic hand orthosis in combination with electrical stimulation shows a shift from no dexterity to dexterity. As to the users' experience regarding the dynamic hand orthosis, patients perceive a high-intrinsic motivation and sense of self-regulation. Combining the orthosis with electrical stimulation creates opportunities for a nonfunctional hand towards task