Sample records for hand rub technique

  1. Revisiting the hand wipe versus gel rub debate: is a higher-ethanol content hand wipe more effective than an ethanol gel rub?

    PubMed

    D'Antonio, Natalie N; Rihs, John D; Stout, Janet E; Yu, Victor L

    2010-11-01

    The Centers for Disease Control and Prevention's guidelines for hand hygiene state that the use of alcohol-based hand wipes is not an effective substitute for the use of an alcohol-based hand rub or handwashing with an antimicrobial soap and water. The objective of this study was to determine whether a hand wipe with higher ethanol content (65.9%) is as effective as an ethanol hand rub or antimicrobial soap in removing bacteria and spores from hands. In two separate experiments, the hands of 7 subjects were inoculated with a suspension of Serratia marcescens or Geobacillus stearothermophilus. Subjects washed with each of 3 different products: 65.9% ethanol hand wipes (Sani-Hands ALC), 62% ethanol gel rub (Purell), and antimicrobial soap containing 0.75% triclosan (Kindest Kare). A total of 56 observations were analyzed for S marcescens removal and 70 observations were analyzed for G stearothermophilus removal. The rank order of product efficacy for both bacteria and spore removal was antibacterial soap > 65.9% ethanol hand wipes >62% ethanol hand rub. Mean S marcescens log reductions (±SD) for the 65.9% ethanol alcohol wipe, 62% ethanol alcohol rub, and antimicrobial foam soap were 3.44 ± 0.847, 2.32 ± 1.065, and 4.44 ± 1.018, respectively (P < .001). Mean G stearothermophilus log reductions for the 65.9% ethanol wipe, 62% ethanol rub, and antimicrobial foam soap were 0.51 ± 0.26, -0.8 ± 0.32 increase over baseline, and 1.72 ± 0.62, respectively (P < .001). The alcohol-based hand wipe containing 65.9% ethanol was significantly more effective than the 62% ethanol rub in reducing the number of viable bacteria and spores on the hands. Copyright © 2010 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  2. Surgical hand antisepsis in veterinary practice: evaluation of soap scrubs and alcohol based rub techniques.

    PubMed

    Verwilghen, Denis R; Mainil, Jacques; Mastrocicco, Emilie; Hamaide, Annick; Detilleux, Johann; van Galen, Gaby; Serteyn, Didier; Grulke, Sigrid

    2011-12-01

    Recent studies have shown that hydro-alcoholic solutions are more efficient than traditional medicated soaps in the pre-surgical hand antisepsis of human surgeons but there is little veterinary literature on the subject. The aim of this study was to compare the efficiency of medicated soaps and a hydro-alcoholic solution prior to surgery using an in-use testing method in a veterinary setting. A preliminary trial was performed that compared the mean log(10) number of bacterial colony forming units (CFU) and the reduction factors (RF) between two 5-min hand-scrubbing sessions using different soaps, namely, povidone iodine (PVP) and chlorhexidine gluconate (CHX), and the 1.5-min application of a hydro-alcoholic rub. A clinical in-use trial was then used to compare the hydro-alcoholic rub and CHX in a surgical setting. Sampling was performed using finger printing on agar plates. The hydro-alcoholic rub and CHX had a similar immediate effect, although the sustained effect was significantly better for the hydro-alcoholic rub, while PVP had a significantly lower immediate and sustained effect. The hydro-alcoholic rub showed good efficiency in the clinical trial and could be considered as a useful alternative method for veterinary surgical hand antisepsis. Copyright © 2010 Elsevier Ltd. All rights reserved.

  3. Hand hygiene with alcohol hand rub and gloves reduces the incidence of late onset sepsis in preterm neonates.

    PubMed

    Janota, Jan; Šebková, Sylva; Višňovská, Magda; Kudláčková, Jana; Hamplová, Drahomíra; Zach, Jiří

    2014-10-01

    To assess the impact of a hand hygiene protocol, using hand washing, alcohol hand rub and gloves when caring for preterm infants born after 31 weeks of gestation, on the incidence of neonatal late onset sepsis (LOS). All babies delivered between 32 + 0 and 36 + 6 weeks gestation and admitted to the neonatal intensive care unit during a 14-month period were included. We followed a hand hygiene protocol with hand washing and alcohol hand rub (hand rub period) for the first 7 months and a protocol of hand washing, alcohol hand rub and gloves (gloves period) for the second 7 months. The hand rub and gloves groups consisted of 111 and 89 patients, respectively. Five patients were diagnosed with a total of six episodes of LOS in the hand rub group, and the incidence of LOS during the hand rub period was 2.99/1000 hospital days and 54.1/1000 admissions. There were no patients diagnosed with LOS during the gloves period (significant decrease, p = 0.028). Using a hand hygiene protocol with hand washing, hand rub and gloves significantly reduced the incidence of LOS in preterm newborns, and the results suggest that it may produce a sustained improvement in the infection rate. ©2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  4. Waterless Hand Rub Versus Traditional Hand Scrub Methods for Preventing the Surgical Site Infection in Orthopedic Surgery.

    PubMed

    Iwakiri, Kentaro; Kobayashi, Akio; Seki, Masahiko; Ando, Yoshiyuki; Tsujio, Tadao; Hoshino, Masatoshi; Nakamura, Hiroaki

    2017-11-15

    MINI: Fourteen hundred consecutive patients were investigated for evaluating the utility of waterless hand rub before orthopaedic surgery. The risk in the surgical site infection incidence was the same, but costs of liquids used for hand hygiene were cheaper and the hand hygiene time was shorter for waterless protocol, compared with traditional hand scrub. A retrospective cohort study with prospectively collected data. The aim of this study was to compare SSI incidences, the cost of hand hygiene agents, and hand hygiene time between the traditional hand scrub and the waterless hand rub protocols before orthopedic surgery. Surgical site infections (SSI) prolong hospitalization and are a leading nosocomial cause of morbidity and a source of excess cost. Recently, a waterless hand rub protocol comprising alcohol based chlorhexidine gluconate for use before surgery was developed, but no studies have yet examined its utility in orthopedic surgery. Fourteen hundred consecutive patients who underwent orthopedic surgery (spine, joint replacement, hand, and trauma surgeries) in our hospital since April 1, 2012 were included. A total of 712 cases underwent following traditional hand scrub between April 1, 2012 and April 30, 2013 and 688 cases underwent following waterless hand rub between June 1, 2013 and April 30, 2014. We compared SSI incidences within all and each subcategory between two hand hygiene protocols. All patients were screened for SSI within 1 year after surgery. We compared the cost of hand hygiene agents and hand hygiene time between two groups. The SSI incidences were 1.3% (9 of 712) following the traditional protocol (2 deep and 7 superficial infections) and 1.1% (8 of 688) following the waterless protocol (all superficial infections). There were no significant differences between the two groups. The costs of liquids used for one hand hygiene were about $2 for traditional hand scrub and less than $1 for waterless hand rub. The mean hand hygiene time was 264

  5. Towards objective hand hygiene technique assessment: validation of the ultraviolet-dye-based hand-rubbing quality assessment procedure.

    PubMed

    Lehotsky, Á; Szilágyi, L; Bánsághi, S; Szerémy, P; Wéber, G; Haidegger, T

    2017-09-01

    Ultraviolet spectrum markers are widely used for hand hygiene quality assessment, although their microbiological validation has not been established. A microbiology-based assessment of the procedure was conducted. Twenty-five artificial hand models underwent initial full contamination, then disinfection with UV-dyed hand-rub solution, digital imaging under UV-light, microbiological sampling and cultivation, and digital imaging of the cultivated flora were performed. Paired images of each hand model were registered by a software tool, then the UV-marked regions were compared with the pathogen-free sites pixel by pixel. Statistical evaluation revealed that the method indicates correctly disinfected areas with 95.05% sensitivity and 98.01% specificity. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  6. Recommendations and requirements for soap and hand rub dispensers in healthcare facilities.

    PubMed

    Assadian, Ojan; Kramer, Axel; Christiansen, Bärbel; Exner, Martin; Martiny, Heike; Sorger, Arno; Suchomel, Miranda

    2012-01-01

    Hand hygiene is one of the most important measures to prevent transmission of infectious agents and plays a major role in prevention of infection in any type of healthcare setting. While requirements for the efficacy of hand disinfectants are defined in European testing norms such as the EN 1500 for hygienic hand disinfection or EN 12791 for surgical hand preparation, no specific recommendations for hand rub dispensers and liquid soap dispensers have been given yet. Therefore, the intention of the present recommendation on soap and hand rub dispensers in healthcare facilities is to close this gap and to enhance future improvement of dispenser functionality and design. Regardless of manufacture and design of a hand rub or liquid soap dispensers the following requirements shall be met in healthcare facilities:Triggering the dispenser must be possible without using hands. Sensor- or elbow-operated dispensers both fulfill this requirement. Dispensers must be only refillable in a modality where the content, be it a hand rub or liquid soap, cannot be contaminated. This is achieved best by using replaceable cartridge systems. Refilling through "top-up" must not be possible. The disperser should allow usage of different types of cartridges made by different manufacturers. Dispensers must be operated and maintained such that a microbial contamination of the pump nozzle may easily be avoided. It must be possible to identify the products used in a dispenser easily and without any manipulation. Identifying the type of product, be it a hand rub or a liquid soap, as well as reading the product's name and critical manufacturers' warnings must be possible at any time. The disperser must allow identification of the level of the used product without any further manipulation at any time. The design of the dispenser must allow easy cleaning and disinfection the outside and inside of the dispenser. The manufacturer of the dispenser must provide the user with information on applicable

  7. [Development of alternative to animal experiment in evaluation of skin irritation caused by alcohol-based hand rubs].

    PubMed

    Yamamoto, Nobuyuki; Miyamoto, Koji; Katoh, Masakazu

    2010-08-01

    Alcohol-based hand rubs are widely used for infection control in clinical practice. However, it is known that frequent use of the alcohol-based hand rubs may cause skin irritation. To predict the skin irritation in human, animal experiments are quite useful. Especially, the Draize Test using rabbits is suitable for this purpose because their skin is highly sensitive. On the other hand, the development of alternative to animal experiments is important not only from the viewpoint of ethical aspects but also from the efficient research and development. Reconstructed human epidermis (RhE) was developed as a human skin equivalent model in vitro, and has been applied to the evaluation of skin irritation. But the RhE has not been utilized for the evaluation of alcohol-based hand rubs because of the high skin permeability and cytotoxicity of alcohols. The aim of this study was to develop a new method using the RhE in evaluation of skin irritation caused by alcohol-based hand rubs. The authors propose an experimental technique named "Skin model blowing method (SMBM)" consisting of the sequential procedure as follows; applying small amount of testing sample on RhE, blow-dry, post incubation, and cell viability measurement. According to the SMBM, the skin irritation caused by alcohol-based hand rubs could be evaluated under the similar condition of their actual use. It was found that a high correlation existed between the cell viability obtained from SMBM and the skin irritation index in rabbit which had been reported previously.

  8. Single treatment with ethanol hand rub is ineffective against human rhinovirus--hand washing with soap and water removes the virus efficiently.

    PubMed

    Savolainen-Kopra, Carita; Korpela, Terttu; Simonen-Tikka, Marja-Leena; Amiryousefi, Ali; Ziegler, Thedi; Roivainen, Merja; Hovi, Tapani

    2012-03-01

    Ethanol-containing hand rubs are used frequently as a substitute for hand washing with water and soap. However, not all viruses are inactivated by a short term rubbing with alcohol. The capacity of a single round of instructed and controlled hand cleaning with water and soap or ethanol-containing hand rub, respectively, was tested for removal of human rhinovirus administered onto the skin of healthy volunteers on the back of the hands. Hand washing with soap and water appeared to be much more efficient for removing rhinoviruses from skin than rubbing hands with an ethanol-containing disinfectant. After washing with soap and water the virus was detected in 3/9 (33.3%) test persons from the left hand and 1/9 (11.1%) cases from the right hand, whereas the virus was detected invariably by real-time RT-PCR from both hands after cleaning with alcohol hand rub (P-value <0.01). Both substances evaluated clinically were also tested in vitro for virucidal efficacy against Human rhinovirus2 (HRV2) using a standardized assay. Both tested substances were poor within the contact time used in the hand-cleaning test. In conclusion, thorough and conventional hand washing with water and soap can clean efficiently hands contaminated with the virus responsible for an extensive share of common cold episodes. Copyright © 2012 Wiley Periodicals, Inc.

  9. Sustained antibacterial effect of a hand rub gel incorporating chlorhexdine-loaded nanocapsules (Nanochlorex).

    PubMed

    Nhung, Dang Thi Tuyet; Freydiere, Anne-Marie; Constant, Hélène; Falson, Françoise; Pirot, Fabrice

    2007-04-04

    In the present study, an original chlorhexidine-loaded nanocapsule-based gel (Nanochlorex) was tested as hand rub gel against the resident skin flora in comparison with 2-propanol 60% (v/v) and 62% (v/v) ethanol-based gel (Purell). After 30-s hand rub, the immediate bactericidal effect of Nanochlorex was found comparable to 2-propanol 60% (v/v) (reduction factor, RF: 0.30+/-0.35 versus 0.38+/-0.55, P>0.05) against aerobic bacteria, whereas the post-values of surviving anaerobes were shown significantly lower from Nanochlorex (P<0.001) and insignificant from 2-propanol 60% (v/v) (P>0.05). Sustained antibacterial effect of Nanochlorex was confirmed against the resident and transient hand flora in two sets of experiment. In the first, the results obtained with the glove-juice technique showed that the bactericidal effect induced by Nanochlorex hand rub persisted throughout 3-h period, while Purell failed to reduce significantly the post-values of surviving bacteria. In the second, repeated artificial contaminations with Staphylococcus epidermidis was carried out onto ex vivo human skin pre-treated by either Nanochlorex or Purell for 5min, then maintained in cell diffusion apparatus for 4h. The log(10) reduction of surviving bacteria was significantly higher with Nanochlorex than that determined with Purell after three successive contaminations (from approximately 5.5 to 1.5 log(10) reduction for Nanochlorex between the first and the third contamination; approximately 1log(10) reduction for Purell throughout the experiment), confirming the sustained antibacterial effect of chlorhexidine-loaded nanocapsule-based gel. The immediate and sustained antibacterial effect of Nanochlorex was explained by chlorhexidine carrier system which improved the drug targeting to bacteria and reduced from osmotic gel further bacterial growth on the skin. Nanochlorex) might constitute a promising approach for hygienic hand disinfection in care practice performing multiple procedures.

  10. Quantitative impact of direct, personal feedback on hand hygiene technique.

    PubMed

    Lehotsky, Á; Szilágyi, L; Ferenci, T; Kovács, L; Pethes, R; Wéber, G; Haidegger, T

    2015-09-01

    This study investigated the effectiveness of targeting hand hygiene technique using a new training device that provides objective, personal and quantitative feedback. One hundred and thirty-six healthcare workers in three Hungarian hospitals participated in a repetitive hand hygiene technique assessment study. Ultraviolet (UV)-labelled hand rub was used at each event, and digital images of the hands were subsequently taken under UV light. Immediate objective visual feedback was given to participants, showing missed areas on their hands. The rate of inadequate hand rubbing reduced from 50% to 15% (P < 0.001). However, maintenance of this reduced rate is likely to require continuous use of the electronic equipment. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  11. Preoperative Hand Decontamination in Ophthalmic Surgery: A Comparison of the Removal of Bacteria from Surgeons' Hands by Routine Antimicrobial Scrub versus an Alcoholic Hand Rub.

    PubMed

    Forer, Yaara; Block, Colin; Frenkel, Shahar

    2017-09-01

    The goal of this experiment was to evaluate and compare the antimicrobial efficacy of routine preoperative hand washing using commercial medicated sponge brushes versus an alcoholic hand rub, by comparing bacterial growth on ophthalmic surgeons' hands after application of each of these methods. Twenty ophthalmic surgeons were recruited at the Hadassah-Hebrew University Medical Center in Jerusalem, Israel. Samples were collected twice from the hands of each surgeon after hand decontamination using two different protocols during routine surgical practice. The routine preparation consisted of a 3-minute surgical scrub using commercial brush-sponges incorporating either 4% chlorhexidine gluconate (CHG) or 1% povidone-iodine (PVP-I) formulations with detergent, followed by drying the hands with a sterile towel, while the 70% ethanol solution was applied for 60-seconds and allowed to air dry. Half of the group was randomly assigned to provide samples first after the routine method and the alcoholic solution a week later, and the other half of the group was sampled in the reverse order. Viable counts of bacteria were evaluated using a modified glove juice method. Bacterial colonies were enumerated after incubation for 24 hours and expressed as colony forming units (CFU)/mL for each pair of hands. Geometric mean counts were 1310 and 39 CFU/mL, in the routine and alcohol rub groups, respectively, representing a mean log 10 reduction in 1.53. The difference between the paired bacterial counts for the routine versus the alcohol rub was statistically significant (p < 0.0001). There was no statistically significant difference between log 10 reductions for CHG and PVP-I (p = 0.97). This study provides evidence that an alcohol rub protocol is more effective in reducing bacterial counts on hands than routine surgical hand preparation with PVP-I and CHG in a population of practicing ophthalmic surgeons in the operative clinical setting. Thus, it provides a safe alternative as a

  12. Survey of attitudes and practices of Irish nursing students towards hand hygiene, including handrubbing with alcohol-based hand rub.

    PubMed

    Kingston, Liz M; O'Connell, Nuala H; Dunne, Colum P

    2017-05-01

    Hand hygiene is widely recognised as the most important measure a healthcare worker can take in preventing the spread of healthcare associated infections. As a member of the healthcare team, nursing students have direct patient contact during clinical practice; hence, good hand hygiene practice among nursing students is essential. Low to moderate levels of hand hygiene knowledge and poor attitudes and practices are reported among nursing students. However, less is known about their attitudes and practices of handrubbing with ABHR, even though handrubbing is the recommended optimum practice in most situations. The aim of this study was to explore attitudes and practices of hand hygiene, in particular handrubbing with alcohol-based hand rub, among nursing students in Ireland. This survey employed a descriptive, self-report design using a questionnaire to gather data. It was administered electronically to all undergraduate nursing students (n=342) in the Department of Nursing and Midwifery at the University of Limerick, Ireland in March and April 2015. Response rate was 66%. Attitudes towards hand hygiene were generally positive. Compliance with hand hygiene after contact with body fluid was high (99.5%) and before a clean or aseptic procedure (98.5%). However, suboptimal practices emerged, before touching a patient (85%), after touching a patient (87%) and after touching patients' surroundings (61%), with first year students more compliant than fourth year students. 16% of students were not aware of the clinical contraindications for using alcohol-based hand rub and 9% did not know when to use soap and water and when to use alcohol-based hand rub. Educators and practitioners play an important role in ensuring that nursing students develop appropriate attitudes towards hand hygiene and engage in optimal handrubbing practices. Raising awareness among nursing students of their responsibility in preventing the occurrence and reducing the transmission of HCAI as an on

  13. Epidemiologic Background of Hand Hygiene and Evaluation of the Most Important Agents for Scrubs and Rubs

    PubMed Central

    Kampf, Günter; Kramer, Axel

    2004-01-01

    The etiology of nosocomial infections, the frequency of contaminated hands with the different nosocomial pathogens, and the role of health care workers' hands during outbreaks suggest that a hand hygiene preparation should at least have activity against bacteria, yeasts, and coated viruses. The importance of efficacy in choosing the right hand hygiene product is reflected in the new Centers for Disease Control and Prevention guideline on hand hygiene (J. M. Boyce and D. Pittet, Morb. Mortal. Wkly. Rep. 51:1-45, 2002). The best antimicrobial efficacy can be achieved with ethanol (60 to 85%), isopropanol (60 to 80%), and n-propanol (60 to 80%). The activity is broad and immediate. Ethanol at high concentrations (e.g., 95%) is the most effective treatment against naked viruses, whereas n-propanol seems to be more effective against the resident bacterial flora. The combination of alcohols may have a synergistic effect. The antimicrobial efficacy of chlorhexidine (2 to 4%) and triclosan (1 to 2%) is both lower and slower. Additionally, both agents have a risk of bacterial resistance, which is higher for chlorhexidine than triclosan. Their activity is often supported by the mechanical removal of pathogens during hand washing. Taking the antimicrobial efficacy and the mechanical removal together, they are still less effective than the alcohols. Plain soap and water has the lowest efficacy of all. In the new Centers for Disease Control and Prevention guideline, promotion of alcohol-based hand rubs containing various emollients instead of irritating soaps and detergents is one strategy to reduce skin damage, dryness, and irritation. Irritant contact dermatitis is highest with preparations containing 4% chlorhexidine gluconate, less frequent with nonantimicrobial soaps and preparations containing lower concentrations of chlorhexidine gluconate, and lowest with well-formulated alcohol-based hand rubs containing emollients and other skin conditioners. Too few published data

  14. A Kinetic Study Using Evaporation of Different Types of Hand-Rub Sanitizers

    ERIC Educational Resources Information Center

    Pinhas, Allan R.

    2010-01-01

    Alcohol-based hand-rub sanitizers are the types of products that hospital professionals use very often. These sanitizers can be classified into two major groups: those that contain a large quantity of thickener, and thus are a gel, and those that contain a small quantity of thickener, and thus remain a liquid. In an effort to create a laboratory…

  15. Inefficacy of alcohol-based hand rub on mites in a patient with hyperkeratotic scabies.

    PubMed

    Cinotti, E; Perrot, J L; Labeille, B; Maguet, H; Couzan, C; Flori, P; Cambazard, F

    2015-03-01

    The World Health Organization is strongly promoting alcohol-based hand rubs to interrupt transmission of pathogens within the healthcare environment, and in some hospitals they are being recommended in cases of scabies. However, there are no studies that demonstrate the efficacy of such hand rubs against scabies. To evaluate the viability of Sarcoptes scabiei after the application of various topical antiseptics used for hand hygiene, and the effect of hand washing on the number of parasites present on the skin surface of a patient with scabies. We applied three different topical antiseptics (two alcohol-based and one povidone-iodine-based) to the skin of one hand that was affected by scabies, and took a skin scraping of each area to evaluate the viability of the mites over time. A skin scraping of a control area without antiseptic application was also taken. We also tested the antiseptics directly on the mites. Statistical comparison between the percentages of vital mites in the different samples was assessed using the χ(2) test. We also captured a dermoscopic image of the other hand before and after hand washing to count the number of parasites on the skin surface. Topical antiseptics did not reduce the number of living mites compared with control skin, and hand washing did not reduce the number of parasites on the skin surface. Application of topical antiseptics does not reduce the viability of S. scabiei, and is therefore unable to prevent the transmission of scabies. The usefulness of hand washing in preventing transmission of scabies to new subjects remains to be investigated. © 2014 British Association of Dermatologists.

  16. Surgical hand disinfection with a propanol-based hand rub: equivalence of shorter application times.

    PubMed

    Kampf, G; Ostermeyer, C; Heeg, P

    2005-04-01

    The aim of this study was to determine the efficacy of a propanol-based hand rub at application times shorter than 3 min. The bacterial pre-value was obtained from the finger tips (prEN 12791). Subjects treated their hands with the reference procedure (n-propanol, 60%) for 3 min or the product (crossover design). Sterillium was applied for 3, 2, 1.5 and 1 min. Four other preparations were tested for 1 min. Post-values (immediate effect) were taken from one hand, and the other hand was gloved for 3h. After the gloves were removed, the second post-value was taken (sustained effect). Sterillium was more effective than the reference procedure at 3, 2 and 1.5 min (immediate and sustained effect). The immediate effect after 1 min was significantly lower [mean log(10) reduction factor (RF): 1.91+/-0.90 vs. 2.52+/-0.95; P=0.001], whereas the sustained effect was not (mean RF: 1.81+/-1.06 vs. 2.05+/-1.14; P=0.204). All other preparations failed the efficacy requirement at 1 min for both the immediate and sustained effect. Using 2 x 3 mL Sterillium for a total of 1.5 min for surgical hand disinfection was at least as effective as the 3-min reference disinfection.

  17. Assessment of hand hygiene techniques using the World Health Organization's six steps.

    PubMed

    Arias, Ariadna V; Garcell, Humberto G; Ochoa, Yagdeline R; Arias, Katiana F; Miranda, Fernando R

    2016-01-01

    The quality of hand hygiene was evaluated via direct observation for compliance with the six recommended World Health Organization steps. A total of 2497 HH opportunities, of which 1573 (63.0%) were hand rubs, were monitored over a five month period. Compliance was higher in nurses compared with physicians and auxiliaries and in steps 1 and 2 for hand rubs as well as the first three steps of hand washing, with lower rates after these steps. Rubbing of the thumbs and fingertips achieved the lowest rates of compliance in both HH types. A combination of the five recommended moments and six steps and staff education is recommended to improve the quality of hand hygiene. Copyright © 2015 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  18. Prevalence of muzzle-rubbing and hand-rubbing behavior in wild chimpanzees in Mahale Mountains National Park, Tanzania.

    PubMed

    Corp, Nadia; Hayaki, Hitoshige; Matsusaka, Takahisa; Fujita, Shiho; Hosaka, Kazuhiko; Kutsukake, Nobuyuki; Nakamura, Michio; Nakamura, Miho; Nishie, Hitonaru; Shimada, Masaki; Zamma, Koichiro; Wallauer, William; Nishida, Toshisada

    2009-04-01

    In 1998, four chimpanzees in the Mahale Mountains National Park, Tanzania, were observed wiping their mouths with non-detached leaves or stalks of grass, or rubbing their mouths with a tree trunk or branch, especially while eating lemons. The number of mouth-wiping/rubbing individuals increased to 18 in 1999. By 2005, 29 chimpanzees were documented wiping/rubbing their muzzles in this way. Although it is difficult to determine whether the chimpanzees acquired this behavior as a result of trial and error or social learning, the fact that chimpanzees at other sites perform this behavior with detached leaves or leafy twigs much more often than with intact items suggests the possibility that cleaning with intact plant parts at Mahale spread via social learning.

  19. Hand hygiene--comparison of international recommendations.

    PubMed

    Wendt, C

    2001-08-01

    The value of hand hygiene for the prevention of cross-infection was first observed in the middle of the 19th century. Since then, which procedure is the most suitable for hand hygiene has been repeatedly discussed and several different guidelines and recommendations have been published. The aim of this review is to compare different recommendations for hand hygiene regarding technique and indication. Medline, the internet and a personal library were searched to obtain as many written recommendations as possible. In addition, a small questionnaire was sent by e-mail to 20 international colleagues. As a result, written recommendations from 10 countries could be compared. Recommended methods of hand hygiene include handwashing (washing hands with plain soap), hygienic handwash (washing hands with medicated soap) and hygienic hand-rub (use of antiseptic rubs). In most countries handwashing and hygienic handwash are the methods of choice and only in central European countries is hygienic hand-rub the preferred technique. Situations in which performance of hand hygiene is recommended are comparable. However, no single indication is recommended in all guidelines. Hand hygiene is most often recommended before performing invasive procedures and after microbial contamination. Guidelines should be clear and easy to follow for them to become standard of care. Thus, guidelines are needed that do not leave to the health care worker a decision as to whether hand hygiene is indicated.

  20. Outbreak of human metapneumovirus infection in psychiatric inpatients: implications for directly observed use of alcohol hand rub in prevention of nosocomial outbreaks.

    PubMed

    Cheng, V C C; Wu, A K L; Cheung, C H Y; Lau, S K P; Woo, P C Y; Chan, K H; Li, K S M; Ip, I K S; Dunn, E L W; Lee, R A; Yam, L Y C; Yuen, K Y

    2007-12-01

    Nosocomial outbreaks of infectious diseases in psychiatric facilities are not uncommon but the implementation of infection control measures is often difficult. Here, we report an outbreak of an acute respiratory illness in a psychiatric ward between 29 July and 20 August 2005 involving 31 patients. Human metapneumovirus was detected in seven (23%) patients by reverse transcription-polymerase chain reaction and nucleotide sequencing. A review of outbreak surveillance records showed that six nosocomial outbreaks occurred in the year 2005, of which four (67%) were confirmed or presumably related to a respiratory viral infection. Directly observed deliveries of alcohol hand rub 4-hourly during daytime to all psychiatric patients was instituted in December 2005. Only one nosocomial respiratory viral outbreak occurred in the following year. The total number of patients and staff involved in nosocomial outbreaks due to presumed or proven respiratory virus infections decreased significantly from 60 to six (P<0.001), whereas those due to all types of nosocomial outbreaks also decreased from 70 to 24 (P=0.004). Alcohol hand rub has been shown to have potent bactericidal and virucidal activity against a wide range of nosocomial pathogens. Regular use of directly observed alcohol hand rub may decrease the incidence and scale of nosocomial outbreaks due to enveloped respiratory viruses especially in mentally incapacitated patients.

  1. Comparison of 3 in vivo methods for assessment of alcohol-based hand rubs.

    PubMed

    Edmonds-Wilson, Sarah; Campbell, Esther; Fox, Kyle; Macinga, David

    2015-05-01

    Alcohol-based hand rubs (ABHRs) are the primary method of hand hygiene in health-care settings. ICPs increasingly are assessing ABHR product efficacy data as improved products and test methods are developed. As a result, ICPs need better tools and recommendations for how to assess and compare ABHRs. Two ABHRs (70% ethanol) were tested according to 3 in vivo methods approved by ASTM International: E1174, E2755, and E2784. Log10 reductions were measured after a single test product use and after 10 consecutive uses at an application volume of 2 mL. The test method used had a significant influence on ABHR efficacy; however, in this study the test product (gel or foam) did not significantly influence efficacy. In addition, for all test methods, log10 reductions obtained after a single application were not predictive of results after 10 applications. Choice of test method can significantly influence efficacy results. Therefore, when assessing antimicrobial efficacy data of hand hygiene products, ICPs should pay close attention to the test method used, and ensure that product comparisons are made head to head in the same study using the same test methodology. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. Quest for a Realistic In Vivo Test Method for Antimicrobial Hand-Rub Agents: Introduction of a Low-Volume Hand Contamination Procedure▿

    PubMed Central

    Macinga, David R.; Beausoleil, Christopher M.; Campbell, Esther; Mulberry, Gayle; Brady, Ann; Edmonds, Sarah L.; Arbogast, James W.

    2011-01-01

    A novel method has been developed for the evaluation of alcohol-based hand rubs (ABHR) that employs a hand contamination procedure that more closely simulates the in-use conditions of ABHR. Hands of human subjects were contaminated with 0.2 ml of a concentrated suspension of Serratia marcescens (ATCC 14756) to achieve baseline contamination between 8 and 9 log10 CFU/hand while allowing product to be applied to dry hands with minimal soil load. Evaluation of 1.5 ml of an ABHR gel containing 62% ethanol produced log10 reductions of 2.66 ± 0.96, 2.40 ± 0.50, 2.41 ± 0.61, and 2.33 ± 0.49 (means ± standard deviations) after 1, 3, 7, and 10 successive contamination/product application cycles. In a study comparing this low-volume contamination (LVC) method to ASTM E1174, product dry times were more realistic and log10 reductions achieved by the ABHR were significantly greater when LVC was employed (P < 0.05). These results indicate that a novel low-volume hand contamination procedure, which more closely represents ABHR use conditions, provides more realistic estimates of in-use ABHR efficacies. Based on the LVC method, log10 reductions produced by ABHR were strongly dependent on the test product application volume (P < 0.0001) but were not influenced by the alcohol concentration when it was within the range of 62 to 85% (P = 0.378). PMID:22003004

  3. The Effects of Surgical Hand Scrubbing Protocols on Skin Integrity and Surgical Site Infection Rates: A Systematic Review.

    PubMed

    Liu, Liang Qin; Mehigan, Sinead

    2016-05-01

    This systematic review aimed to critically appraise and synthesize updated evidence regarding the effect of surgical-scrub techniques on skin integrity and the incidence of surgical site infections. Databases searched include the Cumulative Index to Nursing and Allied Health Literature, MEDLINE, Embase, and Cochrane Central. Our review was limited to eight peer-reviewed, randomized controlled trials and two nonrandomized controlled trials published in English from 1990 to 2015. Comparison models included traditional hand scrubbing with chlorhexidine gluconate or povidone-iodine against alcohol-based hand rubbing, scrubbing with a brush versus without a brush, and detergent-based antiseptics alone versus antiseptics incorporating alcohol solutions. Evidence showed that hand rubbing techniques are as effective as traditional scrubbing and seem to be better tolerated. Hand rubbing appears to cause less skin damage than traditional scrub protocols, and scrub personnel tolerated brushless techniques better than scrubbing using a brush. Copyright © 2016 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  4. Comparative assessment of local tolerance of alcohols commonly used in alcohol-based hand rubs for hand hygiene.

    PubMed

    Manche, Monique; Foligné, Benoît; Sauty, Mathieu; Platel, Anne; Vercauteren, Eric; Rauwel, Gaétan; Catoire, Sophie; Ficheux, Hervé; Criquelion, Jacques; Nesslany, Fabrice

    2017-10-01

    Hand hygiene plays a key role in nosocomial infection prevention. To achieve users' adherence, products' dermal tolerance is essential. We aimed at making a comparative assessment of skin irritation and phototoxicity of the 3 alcohols commonly used in alcohol-based hand rubs (Ethanol, Propan-2-ol, Propan-1-ol) at 60, 70, 80 or 85% w/w in water or with co-formulates (hydrating, emollient and skin protective agents). In vitro validated OECD methods 439 and 432 were used. For irritation, EpiSkin™ Small Model was the chosen Reconstructed Human Epidermis (RhE). For phototoxicity, co-formulates alone or in mixture with and without alcohol were tested using BALB/c 3T3 cell cultures. Whilst Ethanol and Propan-2-ol could not be differentiated and displayed good skin tolerance profiles, Propan-1-ol based products lead to significant viability impairments of RhE at 60, 70 or 80% and at 60% in the presence of co-formulates. However, these results could not be reproduced in another RhE model. Taking also into account bibliographic data on Propan-1-ol, this suggests that our results are probably related to a lack of specificity of the used RhE. Therefore, it can be relevant in case of significant results to use two different RhE models before performing any classification and/or performing any complementary tests. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Compressor seal rub energetics study

    NASA Technical Reports Server (NTRS)

    Laverty, W. F.

    1978-01-01

    The rub mechanics of compressor abradable blade tip seals at simulated engine conditions were investigated. Twelve statistically planned, instrumented rub tests were conducted with titanium blades and Feltmetal fibermetal rubstrips. The tests were conducted with single stationary blades rubbing against seal material bonded to rotating test disks. The instantaneous rub torque, speed, incursion rate and blade temperatures were continuously measured and recorded. Basic rub parameters (incursion rate, rub depth, abradable density, blade thickness and rub velocity) were varied to determine the effects on rub energy and heat split between the blade, rubstrip surface and rub debris. The test data was reduced, energies were determined and statistical analyses were completed to determine the primary and interactive effects. Wear surface morphology, profile measurements and metallographic analysis were used to determine wear, glazing, melting and material transfer. The rub energies for these tests were most significantly affected by the incursion rate while rub velocity and blade thickness were of secondary importance. The ratios of blade wear to seal wear were representative of those experienced in engine operation of these seal system materials.

  6. Adequate Hand Washing and Glove Use Are Necessary To Reduce Cross-Contamination from Hands with High Bacterial Loads.

    PubMed

    Robinson, Andrew L; Lee, Hyun Jung; Kwon, Junehee; Todd, Ewen; Rodriguez, Fernando Perez; Ryu, Dojin

    2016-02-01

    Hand washing and glove use are the main methods for reducing bacterial cross-contamination from hands to ready-to-eat food in a food service setting. However, bacterial transfer from hands to gloves is poorly understood, as is the effect of different durations of soap rubbing on bacterial reduction. To assess bacterial transfer from hands to gloves and to compare bacterial transfer rates to food after different soap washing times and glove use, participants' hands were artificially contaminated with Enterobacter aerogenes B199A at ∼9 log CFU. Different soap rubbing times (0, 3, and 20 s), glove use, and tomato dicing activities followed. The bacterial counts in diced tomatoes and on participants' hands and gloves were then analyzed. Different soap rubbing times did not significantly change the amount of bacteria recovered from participants' hands. Dicing tomatoes with bare hands after 20 s of soap rubbing transferred significantly less bacteria (P < 0.01) to tomatoes than did dicing with bare hands after 0 s of soap rubbing. Wearing gloves while dicing greatly reduced the incidence of contaminated tomato samples compared with dicing with bare hands. Increasing soap washing time decreased the incidence of bacteria recovered from outside glove surfaces (P < 0.05). These results highlight that both glove use and adequate hand washing are necessary to reduce bacterial cross-contamination in food service environments.

  7. Acoustic emissions diagnosis of rotor-stator rubs using the KS statistic

    NASA Astrophysics Data System (ADS)

    Hall, L. D.; Mba, D.

    2004-07-01

    Acoustic emission (AE) measurement at the bearings of rotating machinery has become a useful tool for diagnosing incipient fault conditions. In particular, AE can be used to detect unwanted intermittent or partial rubbing between a rotating central shaft and surrounding stationary components. This is a particular problem encountered in turbines used for power generation. For successful fault diagnosis, it is important to adopt AE signal analysis techniques capable of distinguishing between various types of rub mechanisms. It is also useful to develop techniques for inferring information such as the severity of rubbing or the type of seal material making contact on the shaft. It is proposed that modelling the cumulative distribution function of rub-induced AE signals with respect to appropriate theoretical distributions, and quantifying the goodness of fit with the Kolmogorov-Smirnov (KS) statistic, offers a suitable signal feature for diagnosis. This paper demonstrates the successful use of the KS feature for discriminating different classes of shaft-seal rubbing.

  8. Rotor vibration caused by external excitation and rub

    NASA Technical Reports Server (NTRS)

    Matsushita, O.; Takagi, M.; Kikuchi, K.; Kaga, M.

    1982-01-01

    For turbomachinery with low natural frequencies, considerations have been recently required for rotor vibrations caused by external forces except unbalance one, such as foundation motion, seismic wave, rub and so forth. Such a forced vibration is investigated analytically and experimentally in the present paper. Vibrations in a rotor-bearing system under a harmonic excitation are analyzed by the modal technique in the case of a linear system including gyroscopic effect. For a nonlinear system a new and powerful quasi-modal technique is developed and applied to the vibration caused by rub.

  9. Better compliance and better tolerance in relation to a well-conducted introduction to rub-in hand disinfection.

    PubMed

    Girard, R; Amazian, K; Fabry, J

    2001-02-01

    The aim of the study was to demonstrate that the introduction of rub-in hand disinfection (RHD) in hospital units, with the implementation of suitable equipment, drafting of specific protocols, and training users, improved compliance of hand disinfection and tolerance of user's hands. In four hospital units not previously using RHD an external investigator conducted two identical studies in order to measure the rate of compliance with, and the quality of, disinfection practices, [rate of adapted (i.e., appropriate) procedures, rate of correct (i.e., properly performed) procedures, rate of adapted and correct procedures carried out] and to assess the state of hands (clinical scores of dryness and irritation, measuring hydration with a corneometer). Between the two studies, the units were equipped with dispensers for RHD products and staff were trained. Compliance improved from 62.2 to 66.5%, quality was improved (rate of adapted procedures from 66.8% to 84.3%, P > or = 10(-6), rate of correct procedures from 11.1% to 28.9%, P > or = 10(-8), rate of adapted and correct procedures from 6.0 to 17.8%, P > or = 10(-8)). The tolerance was improved significantly (P > or = 10(-2)) for clinical dryness and irritation scores, although not significantly for measurements using a corneometer. This study shows the benefit of introducing RHD with a technical and educational accompaniment. Copyright 2001 The Hospital Infection Society.

  10. Degraded Chinese rubbing images thresholding based on local first-order statistics

    NASA Astrophysics Data System (ADS)

    Wang, Fang; Hou, Ling-Ying; Huang, Han

    2017-06-01

    It is a necessary step for Chinese character segmentation from degraded document images in Optical Character Recognizer (OCR); however, it is challenging due to various kinds of noising in such an image. In this paper, we present three local first-order statistics method that had been adaptive thresholding for segmenting text and non-text of Chinese rubbing image. Both visual inspection and numerically investigate for the segmentation results of rubbing image had been obtained. In experiments, it obtained better results than classical techniques in the binarization of real Chinese rubbing image and PHIBD 2012 datasets.

  11. Neonatal ethanol exposure from ethanol-based hand sanitisers in isolettes.

    PubMed

    Hsieh, Shizuka; Sapkota, Amir; Wood, Rebecca; Bearer, Cynthia; Kapoor, Shiv

    2018-01-01

    The aims of this study is to measure the ethanol vapours in the isolette after use of hands cleaned with ethanol-based hand sanitiser (EBHS). Two squirts (1.5 mL) of hand sanitiser were rubbed on hands for 10 or 20 s before inserting the hands in the isolette for 5 min. Ethanol vapours were measured in the isolette with photoionisation detector and alcohol breathalyser for 30 min. Peak ethanol concentration in the isolette was considerably higher with a 10 s hand rub (381±192 ppm) compared with a 20 s hand rub (99±50 ppm), and dissipated to ≤5 ppm within 30 min. Under routine care, EBHS use by care providers exposes neonates in isolettes to 3.7-7.3 or 1.4-2.8 mg/kg ethanol per day with 10 or 20 s hand rubs, respectively. The expected blood level from average single exposure is 0.036 mg/dL with 10 s hand rub and may increase further with multiple exposures in a short period. Preterm neonates in the isolette are at risk of inadvertent exposure to ethanol. The expected blood alcohol level from this exposure is small and below 1 mg/dL level recommended by European Medicines Agency to limit the ethanol exposure in children. The unintended ethanol exposure can be avoided by rubbing hands for at least 20 s after applying EBHS. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Assessment of transpulmonary absorption of ethanol from alcohol-based hand rub.

    PubMed

    Hautemanière, Alexis; Ahmed-Lecheheb, Djihane; Cunat, Lisiane; Hartemann, Philippe

    2013-03-01

    Alcohol-based hand rubs (ABHRs) have been associated with a reduction of nosocomial infections. Despite the worldwide introduction of these products in health care settings, the aim of this study was to assess the transpulmonary absorption of ethanol contains in ABHRs used by health care workers (HCWs) in real conditions of work shift. Twenty-six HCWs of Nancy University Hospital were included. Research consisted in monitoring participants during 4 hours of work shift to assess their exposure to ethanol. The measurement of ethanol vapors in exhaled breath was performed using a class B ethylometer (Alco-Sensor FST). Ethanol concentration in inhaled breath was measured using Gilian pump LFS-113. Concentration of ethanol, acetaldehyde, and acetate in blood and urine samples were determined using gas chromatography with flame ionization detector. Participants were 12% male and 88% female. The mean age was 40 ± 8 years. None of the employees included in the study presented any traces of ethanol or its metabolites in the blood or urine. Ethanol (0.08 ± 0.07 mg/L) was detected in the breath of 10 HCWs at 1 to 2 minutes postexposure. The mean concentration of ethanol in the inhaled air was 46.2 mg/m. Absorption of ethanol vapor from ABHRs among HCWs during their care activities was not detected. Quantification of ethanol fumes inhaled during 4 hours of work shift was below the regulatory limitations of exposure to ethanol. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  13. Hand Hygiene – Evaluation of Three Disinfectant Hand Sanitizers in a Community Setting

    PubMed Central

    Babeluk, Rita; Jutz, Sabrina; Mertlitz, Sarah; Matiasek, Johannes; Klaus, Christoph

    2014-01-01

    Hand hygiene is acknowledged as the single most important measure to prevent nosocomial infections in the healthcare setting. Similarly, in non-clinical settings, hand hygiene is recognised as a key element in helping prevent the spread of infectious diseases. The aim of this study was to evaluate the efficacy of three different disinfectant hand sanitizers in reducing the burden of bacterial hand contamination in 60 healthy volunteers in a community setting, both before and after education about the correct use of hand sanitizers. The study is the first to evaluate the efficacy and ease of use of different formulations of hand rubs used by the general population. The products tested were: Sterillium (perfumed, liquid), desderman pure gel (odorless, gel) and Lavit (perfumed, spray). Sterillium and desderman are EN1500 (hygienic hand rub) certified products (available in pharmacy) and Lavit is non EN1500 certified and available in supermarkets. The two EN1500 certified products were found to be significantly superior in terms of reducing bacterial load. desderman pure gel, Sterillium and Lavit reduced the bacterial count to 6.4%, 8.2% and 28.0% respectively. After education in the correct use of each hand rub, the bacterial load was reduced even further, demonstrating the value of education in improving hand hygiene. Information about the testers' perceptions of the three sanitizers, together with their expectations of a hand sanitizer was obtained through a questionnaire. Efficacy, followed by skin compatibility were found to be the two most important attributes of a hand disinfectant in our target group. PMID:25379773

  14. Rubbing ointments and asthma morbidity in adolescents.

    PubMed

    Reznik, Marina; Sharif, Iman; Ozuah, Philip O

    2004-12-01

    To determine the relationship between the use of rubbing ointments and asthma morbidity in adolescents. Cross-sectional study. Inner-city high school in the Bronx, New York. 165 adolescents with asthma. Asthma morbidity, defined as emergency department (ED) use for asthma in the past year and over the lifetime. While 127 (77%) of subjects used albuterol as the first treatment for their last asthma attack, 18 (11%) used rubbing ointments. The rubs and albuterol groups were similar in asthma severity, mean age, gender, and ethnicity. However, subjects in the the rubs group were less likely than subjects in the albuterol group to have made an ED visit over the past 12 months or over their lifetime. Regression analysis revealed that, after controlling for asthma severity, use of rubs independently predicted less lifetime ED use. After controlling for asthma severity, use of rubs by adolescents with asthma was associated with lower asthma morbidity as measured by ED use.

  15. Blade Tip Rubbing Stress Prediction

    NASA Technical Reports Server (NTRS)

    Davis, Gary A.; Clough, Ray C.

    1991-01-01

    An analytical model was constructed to predict the magnitude of stresses produced by rubbing a turbine blade against its tip seal. This model used a linearized approach to the problem, after a parametric study, found that the nonlinear effects were of insignificant magnitude. The important input parameters to the model were: the arc through which rubbing occurs, the turbine rotor speed, normal force exerted on the blade, and the rubbing coefficient of friction. Since it is not possible to exactly specify some of these parameters, values were entered into the model which bracket likely values. The form of the forcing function was another variable which was impossible to specify precisely, but the assumption of a half-sine wave with a period equal to the duration of the rub was taken as a realistic assumption. The analytical model predicted resonances between harmonics of the forcing function decomposition and known harmonics of the blade. Thus, it seemed probable that blade tip rubbing could be at least a contributor to the blade-cracking phenomenon. A full-scale, full-speed test conducted on the space shuttle main engine high pressure fuel turbopump Whirligig tester was conducted at speeds between 33,000 and 28,000 RPM to confirm analytical predictions.

  16. Influence of rubbing on rotor dynamics, part 1

    NASA Technical Reports Server (NTRS)

    Muszynska, Agnes; Bently, Donald E.; Franklin, Wesley D.; Hayashida, Robert D.; Kingsley, Lori M.; Curry, Arthur E.

    1989-01-01

    The results of analytical and experimental research on rotor-to-stationary element rubbing in rotating machines are presented. A characterization of physical phenomena associated with rubbing, as well as a literature survey on the subject of rub is given. The experimental results were obtained from two rubbing rotor rigs: one, which dynamically simulates the space shuttle main engine high pressure fuel turbopump (HPFTP), and the second one, much simpler, a two-mode rotor rig, designed for more generic studies on rotor-to-stator rubbing. Two areas were studied: generic rotor-to-stator rub-related dynamic phenomena affecting rotating machine behavior and applications to the space shuttle HPFTP. An outline of application of dynamic stiffness methodology for identification of rotor/bearing system modal parameters is given. The mathematical model of rotor/bearing/seal system under rub condition is given. The computer program was developed to calculate rotor responses. Compared with experimental results the computed results prove an adequacy of the model.

  17. Recognition and Cleavage of Related to Ubiquitin 1 (Rub1) and Rub1-Ubiquitin Chains by Components of the Ubiquitin-Proteasome System*

    PubMed Central

    Singh, Rajesh K.; Zerath, Sylvia; Kleifeld, Oded; Scheffner, Martin; Glickman, Michael H.; Fushman, David

    2012-01-01

    Of all ubiquitin-like proteins, Rub1 (Nedd8 in mammals) is the closest kin of ubiquitin. We show via NMR that structurally, Rub1 and ubiquitin are fundamentally similar as well. Despite these profound similarities, the prevalence of Rub1/Nedd8 and of ubiquitin as modifiers of the proteome is starkly different, and their attachments to specific substrates perform different functions. Recently, some proteins, including p53, p73, EGFR, caspase-7, and Parkin, have been shown to be modified by both Rub1/Nedd8 and ubiquitin within cells. To understand whether and how it might be possible to distinguish among the same target protein modified by Rub1 or ubiquitin or both, we examined whether ubiquitin receptors can differentiate between Rub1 and ubiquitin. Surprisingly, Rub1 interacts with proteasome ubiquitin-shuttle proteins comparably to ubiquitin but binds more weakly to a proteasomal ubiquitin receptor Rpn10. We identified Rub1-ubiquitin heteromers in yeast and Nedd8-Ub heteromers in human cells. We validate that in human cells and in vitro, human Rub1 (Nedd8) forms chains with ubiquitin where it acts as a chain terminator. Interestingly, enzymatically assembled K48-linked Rub1-ubiquitin heterodimers are recognized by various proteasomal ubiquitin shuttles and receptors comparably to K48-linked ubiquitin homodimers. Furthermore, these heterologous chains are cleaved by COP9 signalosome or 26S proteasome. A derubylation function of the proteasome expands the repertoire of its enzymatic activities. In contrast, Rub1 conjugates may be somewhat resilient to the actions of other canonical deubiquitinating enzymes. Taken together, these findings suggest that once Rub1/Nedd8 is channeled into ubiquitin pathways, it is recognized essentially like ubiquitin. PMID:23105008

  18. Modeling the rubbing contact in honeycomb seals

    NASA Astrophysics Data System (ADS)

    Fischer, Tim; Welzenbach, Sarah; Meier, Felix; Werner, Ewald; kyzy, Sonun Ulan; Munz, Oliver

    2018-03-01

    Metallic honeycomb labyrinth seals are commonly used as sealing systems in gas turbine engines. Because of their capability to withstand high thermo-mechanical loads and oxidation, polycrystalline nickel-based superalloys, such as Hastelloy X and Haynes 214, are used as sealing material. In addition, these materials must exhibit a tolerance against rubbing between the rotating part and the stationary seal component. The tolerance of the sealing material against rubbing preserves the integrity of the rotating part. In this article, the rubbing behavior at the rotor-stator interface is considered numerically. A simulation model is incorporated into the commercial finite element code ABAQUS/explicit and is utilized to simulate a simplified rubbing process. A user-defined interaction routine between the contact surfaces accounts for the thermal and mechanical interfacial behavior. Furthermore, an elasto-plastic constitutive material law captures the extreme temperature conditions and the damage behavior of the alloys. To validate the model, representative quantities of the rubbing process are determined and compared with experimental data from the literature. The simulation results correctly reproduce the observations made on a test rig with a reference stainless steel material (AISI 304). A parametric study using the nickel-based superalloys reveals a clear dependency of the rubbing behavior on the sliding and incursion velocity. Compared to each other, the two superalloys studied exhibit a different rubbing behavior.

  19. Hand Hygiene Practices Among Indian Medical Undergraduates: A Questionnaire-Based Survey

    PubMed Central

    Modi, Pranav D; Solanki, Rajavi; Modi, Janhavi; Chandramani, Srinath; Gill, Niharika

    2017-01-01

    Background and objectives To prevent the spread of infections in all healthcare settings, hand hygiene must be routinely practiced. Appropriate hand hygiene techniques can go a long way in reducing nosocomial infections, cross-transmission of microorganisms and the risk of occupational exposure to infectious diseases. World Health Organisation (WHO) has taken an incredible approach called “My Five Moments for Hand Hygiene" which defines the key moments when health-care workers should perform hand hygiene. We thus carried out a survey to assess knowledge of hand hygiene practices among undergraduate medical students.  Materials and methods A cross-sectional survey was conducted among 523 Indian medical undergraduates. The questionnaire used was adapted from the WHO hand hygiene knowledge questionnaire for health-care workers and was distributed both, in print and online formats. The response to each question was examined using percentages. Results Nearly 57% (n=298) of medical students who participated in this study did not receive any formal training in hand hygiene. Only 27% (n=141) students knew that the most frequent source of germs responsible for health-care associated infections were the germs already present on or within the patient. Nearly 68.6% (n= 359) students were unaware of the sequence of hand washing and hand rubbing. Although 71.9% (n=376 ) students claimed that they use an alcohol-based hand rub routinely, only 36.1% (n=189 ) students knew the time required for a hand rub to kill the germs on the hands. Overall hand hygiene knowledge was low in 6.9% (n=36), moderate in 80.9% (n=423) and good in 12.2% (n=23) of respondents.  Conclusions The awareness about hand hygiene practices among medical students is low. Nearly 57% (n=298) of the respondents never received any formal training in hand hygiene throughout their course of medical undergraduate study. To prevent the spread of infections in healthcare settings, medical students should be given

  20. Effect of rubbing on the in vitro skin permeation of diclofenac-diethylamine 1.16% gel.

    PubMed

    Hasler-Nguyen, Nathalie; Fotopoulos, Grigorios

    2012-06-21

    Rubbing a topical NSAID (non steroidal anti-inflammatory drug) on the skin may increase local drug permeation, affecting its distribution to the site of pain and inflammation. The present study evaluates this hypothesis, by assessing in vitro the effect on skin permeation of applying diclofenac-dieythylamine 1.16% gel with or without rubbing. A single dose of 5 mg/cm2 diclofenac-diethylamine 1.16% gel was applied on excised human skin mounted in Franz-type diffusion cells without or with rubbing for 45 s. Drug penetration into the skin layers was determined after 1 h using the tape stripping technique. In vitro cutaneous permeation into the receptor fluid of the diffusion chamber was measured up to 24 h. Skin electrical resistance was also recorded. Application of diclofenac-diethylamine 1.16% gel with rubbing resulted to a 5-fold higher flux of diclofenac through the skin than when applied without rubbing at 8 h (P = 0.04). Skin rubbing for 45 s decreased by 2-fold skin electrical resistance when compared to the standard application. Application of diclofenac-diethylamine 1.16% gel with rubbing tended to result in higher accumulation in the stripped skin vs. the superficial skin layers when applied without rubbing (P = 0.2). These results suggest that rubbing may alter the superficial skin layer resulting in a transient faster initial diffusion of topically applied diclofenac through the stratum corneum into the deeper skin layer of the dermis to the tissue target.

  1. Effect of rubbing on the in vitro skin permeation of diclofenac-diethylamine 1.16% gel

    PubMed Central

    2012-01-01

    Background Rubbing a topical NSAID (non steroidal anti-inflammatory drug) on the skin may increase local drug permeation, affecting its distribution to the site of pain and inflammation. The present study evaluates this hypothesis, by assessing in vitro the effect on skin permeation of applying diclofenac-dieythylamine 1.16% gel with or without rubbing. Methods A single dose of 5 mg/cm2 diclofenac-diethylamine 1.16% gel was applied on excised human skin mounted in Franz-type diffusion cells without or with rubbing for 45 s. Drug penetration into the skin layers was determined after 1 h using the tape stripping technique. In vitro cutaneous permeation into the receptor fluid of the diffusion chamber was measured up to 24 h. Skin electrical resistance was also recorded. Results Application of diclofenac-diethylamine 1.16% gel with rubbing resulted to a 5-fold higher flux of diclofenac through the skin than when applied without rubbing at 8 h (P = 0.04). Skin rubbing for 45 s decreased by 2-fold skin electrical resistance when compared to the standard application. Application of diclofenac-diethylamine 1.16% gel with rubbing tended to result in higher accumulation in the stripped skin vs. the superficial skin layers when applied without rubbing (P = 0.2). Conclusion These results suggest that rubbing may alter the superficial skin layer resulting in a transient faster initial diffusion of topically applied diclofenac through the stratum corneum into the deeper skin layer of the dermis to the tissue target. PMID:22720797

  2. Evaluating the tolerability and acceptability of an alcohol-based hand rub - real-life experience with the WHO protocol.

    PubMed

    Wolfensberger, Aline; Durisch, Nina; Mertin, Juliane; Ajdler-Schaeffler, Evelyne; Sax, Hugo

    2015-01-01

    Optimizing user satisfaction with alcohol-based hand rubs (ABHR) may be vital to enhance hand hygiene performance. This study tested the tolerability and acceptability of a new ABHR (EVO9; Ecolab) in healthcare workers under daily working conditions and evaluated the practicability of the corresponding WHO protocol. We strictly applied the WHO single product ABHR evaluation protocol. A trained observer assessed hand skin conditions of healthy volunteers using at least 30 ml ABHR per day during their clinical work at baseline, day 3-5 and one month (visit 1-3). Participants rated ABHR tolerability and acceptability at visit 2 and 3. Additionally, we registered study time for participants and study team. Among 46 volunteers, 76% were female; 37% nurses, 28% physicians. Skin was observer-rated "not" or "incidentally" dry in 64.4%, 77.8%, and 90.9% participants at visit 1, 2, and 3, respectively. EVO9 was scored ≥5 (progressive scale, 1-7) for appearance, intactness, moisture content, and sensation by 95.7%, 97.7%, 88.9%, and 97.8% participants at visit 3, respectively. All WHO benchmarks were exceeded except for "speed of drying" at visit 2, and "texture" at visit 2 and 3. Cumulative study time expenditure was 14 days for the observer and four days for participants. EVO9 was well tolerated and accepted according to the WHO single ABHR evaluation protocol with the potential for improvement for stickiness. The WHO protocol is feasible but requires considerable time and logistics. It does not preclude bias, in this case especially due to the necessary switch to personal dispensers.

  3. Nudging to improve hand hygiene.

    PubMed

    Caris, M G; Labuschagne, H A; Dekker, M; Kramer, M H H; van Agtmael, M A; Vandenbroucke-Grauls, C M J E

    2018-04-01

    Hand hygiene is paramount to prevent healthcare-associated infections, but improving compliance is challenging. When healthcare workers seldom encounter healthcare-associated infections, they will consider the odds of causing infections through poor hand hygiene negligible. Cognitive biases such as these may induce non-compliance. Nudging, 'a friendly push to encourage desired behaviour', could provide an easily implemented, inexpensive measure to address cognitive biases and thus support hand hygiene interventions. To investigate whether behavioural nudges, displayed as posters, can increase the use of alcohol-based hand rub. We developed nudges based on a systematic review of previously described cognitive biases, and tested these through a cross-sectional survey among the target audience. We then conducted a controlled before-after trial on two hospital wards, to assess the effect of these nudges on the use of alcohol-based hand rub, measured with electronic dispensers. Poisson regression analyses adjusted for workload showed that nudges displayed next to dispensers increased their overall use on one ward [poster 1: relative risk: 1.6 (95% confidence interval: 1.2-2.2); poster 2: 1.7 (1.2-2.5)] and during doctor's rounds on both wards [poster 1: ward A: 1.7 (1.1-2.6); ward B: 2.2 (1.3-3.8)]. Use of dispensers without adjacent nudges did not increase. Nudges based on cognitive biases that play a role in hand hygiene, and displayed as posters, could provide an easy, inexpensive measure to increase use of alcohol-based hand rub. When applying nudges to change behaviour, it is important to identify the right nudge for the right audience. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  4. Combined use of alcohol hand rub and gloves reduces the incidence of late onset infection in very low birthweight infants.

    PubMed

    Ng, P C; Wong, H L; Lyon, D J; So, K W; Liu, F; Lam, R K Y; Wong, E; Cheng, A F B; Fok, T F

    2004-07-01

    To assess the incidence of late onset (> 72 hours) infection and necrotising enterocolitis (NEC) in very low birthweight (VLBW) infants in two 36 month periods using two hand hygiene protocols: conventional handwashing (HW; first 36 month period); an alcohol hand rub and gloves technique (HR; second 36 month period). VLBW infants admitted to the neonatal intensive care unit during the period December 1993-November 1999 were eligible. A new hand hygiene protocol using alcohol handrub and gloves was introduced in December 1996. Each patient's case record was reviewed retrospectively by two independent investigators using a standard data collection form. The incidence of NEC and systemic infections, including bacterial or fungal septicaemia, meningitis, and peritonitis, in the two periods were compared. The HW and HR groups contained 161 and 176 VLBW infants respectively. The incidence of late onset systemic infection decreased from 13.5 to 4.8 episodes (including NEC)/1000 patient days after introduction of the HR regimen, representing a 2.8-fold reduction. Similarly, the incidence of Gram positive, Gram negative, and fungal infections decreased 2.5-fold, 2.6-fold, and 7-fold respectively. There was also a significant reduction in the incidence of NEC in the HR group (p < 0.0001). Subgroup analysis revealed that the incidence of methicillin resistant Staphylococcus aureus (MRSA) septicaemia was significantly decreased in the second 36 month period (p = 0.048). The clinical data suggest that infants in the HW group had significantly earlier onset of sepsis (p < 0.05) and required oxygen supplementation for longer (p < 0.05) than those in the HR group. Significantly more VLBW infants were discharged from the neonatal intensive care unit without ever being infected (p < 0.0001), and also significantly fewer infants had more than one episode of infection in the HR group (p < 0.0001). The introduction of the HR protocol was associated with a 2.8-fold reduction in the

  5. Mechanisms of rubbing-related corneal trauma in keratoconus.

    PubMed

    McMonnies, Charles W

    2009-07-01

    Corneal scarring in keratoconus, which is observed prior to contact lens wear and in association with a chronic habit of abnormal rubbing, suggests a keratocyte change to a repair phenotype in response to rubbing trauma. This review examines known and putative mechanisms for rubbing-related corneal trauma and cone formation. Responses to eye rubbing (and possible causal links) may include increased corneal temperature, epithelial thinning, increased concentrations of inflammatory mediators in the precorneal tears, abnormal enzyme activity, large intraocular pressure spikes, high hydrostatic tissue pressure, thixotropically reduced ground substance viscosity, temporary displacement of ground substance from the corneal apex, buckling and flexure of fibrils associated with waves of corneal indentation, biomechanically coupled curvature transfer to the cone apex, slippage between collagen fibrils at the cone apex, and changes to keratocytes due to mechanical trauma and/or high hydrostatic pressure, in addition to scar formation. Cone formation appears to depend on a loss of shear strength and may be a consequence of a reduction in ground substance viscosity and glue function, which could allow the cornea to bend and yield to intraocular pressure. For some forms of keratoconus, a reduction in shear strength and cone-forming deformation may be responses to rubbing trauma. Some of the mechanisms for corneal rubbing trauma may be relevant to post-laser-assisted in situ keratomileusis ectasia or complications following other types of corneal surgery. There appear to be indications for the control of chronic habits of abnormal rubbing.

  6. Hand hygiene for the prevention of nosocomial infections.

    PubMed

    Kampf, Günter; Löffler, Harald; Gastmeier, Petra

    2009-10-01

    The WHO regards hand hygiene as an essential tool for the prevention of nosocomial infection, but compliance in clinical practice is often low. The relevant scientific literature and national and international evidence-based recommendations (Robert Koch Institute [Germany], WHO) were evaluated. Hygienic hand disinfection has better antimicrobial efficacy than hand-washing and is the procedure of choice to be performed before and after manual contact with patients. The hands should be washed, rather than disinfected, only when they are visibly soiled. Skin irritation is quite common among healthcare workers and is mainly caused by water, soap, and prolonged wearing of gloves. Compliance can be improved by training, by placing hand-rub dispensers at the sites where they are needed, and by physicians setting a good example for others. Improved compliance in hand hygiene, with proper use of alcohol-based hand rubs, can reduce the nosocomial infection rate by as much as 40%.

  7. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light...

  8. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light...

  9. Rubbings deposited by cats elicit defensive behavior in rats.

    PubMed

    May, Matthew D; Bowen, Michael T; McGregor, Iain S; Timberlake, William

    2012-12-05

    Laboratory rats display pronounced defensive behaviors when confronted with a range of cat-derived stimuli, including collars worn by a cat, cloths rubbed on a cat, and cat fur. One possible explanation of this phenomenon (the "kairomone hypothesis") is that rats derive a survival advantage by eavesdropping on signals used by cats to communicate with each other. Cats are known to rub their bodies on objects at strategic environmental locations to signal their identity and mating potential to other cats. The current study assessed the sensitivity of laboratory rats to these body rubbings. In Experiment 1, food deprived Sprague-Dawley rats were trained to consume food pellets in one arm of a Y maze. On test day a damp cloth was placed near the food pellets that had been rubbed on a location (wall) where a cat had recently engaged in body rubbing. A control cloth and a collar worn by the cat were also tested. The presence of both the body rubbing residue and the cat collar increased latency to eat and decreased amount of food eaten. The disruption of consummatory behavior in the test environment was still evident 24h later in the absence of odor stimuli. Experiment 2 tested the reaction of naïve Wistar rats to body rubbings using a paradigm in which rats were given the opportunity to hide. Relative to a control condition, rats exposed to a cotton pad wiped on a cat body rubbing location showed increased hiding behavior, decreased exploration and reduced stimulus approach and investigation. These defensive responses persisted for up to 4days following a single stimulus exposure. These results suggest that rats eavesdrop readily on body rubbings cats use for identification purposes, providing further support for a kairomone hypothesis of predator odor avoidance. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Numerical investigations on axial and radial blade rubs in turbo-machinery

    NASA Astrophysics Data System (ADS)

    Abdelrhman, Ahmed M.; Tang, Eric Sang Sung; Salman Leong, M.; Al-Qrimli, Haidar F.; Rajamohan, G.

    2017-07-01

    In the recent years, the clearance between the rotor blades and stator/casing had been getting smaller and smaller prior improving the aerodynamic efficiency of the turbomachines as demand in the engineering field. Due to the clearance reduction between the blade tip and the rotor casing and between rotor blades and stator blades, axial and radial blade rubbing could be occurred, especially at high speed resulting into complex nonlinear vibrations. The primary aim of this study is to address the blade axial rubbing phenomenon using numerical analysis of rotor system. A comparison between rubbing caused impacts of axial and radial blade rubbing and rubbing forces are also aims of this study. Tow rotor models (rotor-stator and rotor casing models) has been designed and sketched using SOILDSWORKS software. ANSYS software has been used for the simulation and the numerical analysis. The rubbing conditions were simulated at speed range of 1000rpm, 1500rpm and 2000rpm. Analysis results for axial blade rubbing showed the appearance of blade passing frequency and its multiple frequencies (lx, 2x 3x etc.) and these frequencies will more excited with increasing the rotational speed. Also, it has been observed that when the rotating speed increased, the rubbing force and the harmonics frequencies in x, y and z-direction become higher and severe. The comparison study showed that axial blade rub is more dangerous and would generate a higher vibration impacts and higher blade rubbing force than radial blade rub.

  11. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220... STANDARDS) United States Standards for Grades of Peaches Definitions § 51.1220 Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light colored, or aggregates more...

  12. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220... STANDARDS) United States Standards for Grades of Peaches Definitions § 51.1220 Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light colored, or aggregates more...

  13. 7 CFR 51.1220 - Leaf or limb rub injury.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Leaf or limb rub injury. 51.1220 Section 51.1220... STANDARDS) United States Standards for Grades of Peaches Definitions § 51.1220 Leaf or limb rub injury. “Leaf or limb rub injury” means that the scarring is not smooth, not light colored, or aggregates more...

  14. [The effectiveness of hand hygiene products on MRSA colonization of health care workers by using CHROMagar MRSA].

    PubMed

    Koçak Tufan, Zeliha; Irmak, Hasan; Bulut, Cemal; Cesur, Salih; Kınıklı, Sami; Demiröz, Ali Pekcan

    2012-04-01

    The aims of this study were; to investigate the hand hygiene compliance of the health care workers (HCWs) during their routine patient care, to determine the methicillin-resistant Staphylococcus aureus (MRSA) hand colonization of the HCWs, to investigate the effect of different hand hygiene products on MRSA colonization and to evaluate the effectiveness of chromogenic agar for detecting MRSA. HCWs were investigated during their routine patient care and hand cultures were taken before and after hand wash/hygiene. Two different techniques were used to obtain the hand cultures: fingertip method (CHROMagar MRSA containing HygiSlide); and direct swab method and then inoculation to CHROMagar MRSA media. MRSA strains grown on those cultures were confirmed with conventional methods. A total of 100 HCWs (of them 61 were female; mean age: 32.7 ± 5.2 years; age range: 25-51 years) involving physicians (n= 33), nurses (n= 38) and health care assistants (n= 29), were included in the study. MRSA was detected in 39% and 11% before hand hygiene and in 13% and 6% after hand hygiene, with HygiSlide CHROMagar media and with CHROMagar in plate media, respectively. No difference were found regarding clinics, occupations, or the type of patient handling in those HCWs who were positive (n= 13) for MRSA colonization following hand hygiene, and those who were negative (n= 26). However, the type of the hand hygiene product used exhibited a statistical difference. None of the seven HCWs who used alcohol based hand rub revealed growth in the second culture while 10 of 19 (53%) HCWs who used soap and three of 13 (23%) HCWs who used chlorhexidine were still colonized with MRSA. In terms of reduction in the MRSA counts, the most effective one was the alcohol based hand rub while the soap was the least, since seven of 19 (37%) HCWs who used soap showed no reduction at all in the MRSA counts. A high ratio of hand colonization with MRSA was detected in our hospital staff (39%). It was shown that

  15. Comparison of hand hygiene procedures for removing Bacillus cereus spores.

    PubMed

    Sasahara, Teppei; Hayashi, Shunji; Hosoda, Kouichi; Morisawa, Yuji; Hirai, Yoshikazu

    2014-01-01

    Bacillus cereus is a spore-forming bacterium. B. cereus occasionally causes nosocomial infections, in which hand contamination with the spores plays an important role. Therefore, hand hygiene is the most important practice for controlling nosocomial B. cereus infections. This study aimed to determine the appropriate hand hygiene procedure for removing B. cereus spores. Thirty volunteers' hands were experimentally contaminated with B. cereus spores, after which they performed 6 different hand hygiene procedures. We compared the efficacy of the procedures in removing the spores from hands. The alcohol-based hand-rubbing procedures scarcely removed them. The soap washing procedures reduced the number of spores by more than 2 log10. Extending the washing time increased the spore-removing efficacy of the washing procedures. There was no significant difference in efficacy between the use of plain soap and antiseptic soap. Handwashing with soap is appropriate for removing B. cereus spores from hands. Alcohol-based hand-rubbing is not effective.

  16. Influence of rubbing on rotor dynamics, part 2

    NASA Technical Reports Server (NTRS)

    Muszynska, Agnes; Bently, Donald E.; Franklin, Wesley D.; Hayashida, Robert D.; Kingsley, Lori M.; Curry, Arthur E.

    1989-01-01

    Rotor dynamic behavior depends considerably on how much the specific physical phenomena accompanying rotor rubbing against the stator is involved. The experimental results of rotor-to-stator rubbing contact are analyzed. The computer code is described for obtaining numerical calculations of rotor-to-stator rubbing system dynamic responses. Computer generated results are provided. The reduced dynamic data from High Pressure Fuel Turbo Pump (HPFTP) hot fire test are given. The results provide some significant conclusions. Information is provided on the electronic instrumentation used in the experimental testing.

  17. Simulated Tip Rub Testing of Low-Density Metal Foam

    NASA Technical Reports Server (NTRS)

    Bowman, Cheryl L.; Jones, Michael G.

    2009-01-01

    Preliminary acoustic studies have indicated that low-density, open-cell, metal foams may be suitable acoustic liner material for noise suppression in high by-pass engines. Metal foam response under simulated tip rub conditions was studied to assess whether its durability would be sufficient for the foam to serve both as a rub strip above the rotor as well as an acoustic treatment. Samples represented four metal alloys, nominal cell dimensions ranging from 60 to 120 cells per inch (cpi), and relative densities ranging from 3.4 to 10 percent. The resulting rubbed surfaces were relatively smooth and the open cell structure of the foam was not adversely affected. Sample relative density appeared to have significant influence on the forces induced by the rub event. Acoustic responses of various surface preparations were measured using a normal incidence tube. The results of this study indicate that the foam s open-cell structure was retained after rubbing and that the acoustic absorption spectra variation was minimal.

  18. Gas Chromatographic Determination of Methyl Salicylate in Rubbing Alcohol: An Experiment Employing Standard Addition.

    ERIC Educational Resources Information Center

    Van Atta, Robert E.; Van Atta, R. Lewis

    1980-01-01

    Provides a gas chromatography experiment that exercises the quantitative technique of standard addition to the analysis for a minor component, methyl salicylate, in a commercial product, "wintergreen rubbing alcohol." (CS)

  19. A step-wise approach towards introduction of an alcohol based hand rub, and implementation of front line ownership- using a, rural, tertiary care hospital in central India as a model.

    PubMed

    Sharma, Megha; Joshi, Rita; Shah, Harshada; Macaden, Ragini; Lundborg, Cecilia Stålsby

    2015-04-29

    Appropriate hand hygiene is a gold standard to combat healthcare associated infections (HAIs). The World Health Organization (WHO) has recommended alcohol based hand rub (ABHR) as the most effective tool to maintain hand hygiene. In resource poor settings commercially available ABHR is not "economically accessible". The objectives of this study were to assess the acceptability of, and to build confidence for an in-house prepared (based on WHO guidelines) alcohol based hand rub among healthcare workers (HCWs) using a rural, tertiary care hospital in central India as an example. A series of activities were developed and conducted based on the Precede-Proceed model, the Trans Theoretical model of behaviour change, Front line ownership and Social marketing. A modified WHO-ABHR formulation, the 'test product' and 'WHO product evaluation form' were used for self assessment of acceptability of the 'test product'. Confidence building activities, as finger tip culture, visual portrayal method and handmade posters, were used in high-risk wards for HAIs, to build confidence for the 'test product' in removing transient flora from the hands. A locally developed feedback from was used to evaluate the impact of the activities conducted. Overall 183 HCWs were enrolled for the assessment of the 'test product' (130- doctors and 53 nurses). Out of these 83% (108/130) doctors and 94% (50/53) nurses were satisfied with the 'test product'. The confidence building activity was conducted with 116 participants (49 doctors). After single use of the 'test product', overall a significant reduction was observed for the CFUs on the blood agar plates (0.77 Log(10), p < 0.001). A complete reduction (100%) in colony forming units on incubated blood agar plates was seen for 13% (15/116) participants. Eighty two percent (95/116) participants expressed their confidence in the 'test product'. The self reported acceptance level for the 'test product' was high. The use of finger tip culture coupled

  20. Rub al Khali, Arabia

    NASA Image and Video Library

    2008-08-08

    NASA Terra spacecraft shows the Rub al Khali, one of the largest sand deserts in the world, encompassing most of the southern third of the Arabian Peninsula; it includes parts of Oman, United Arab Emirates, and Yemen.

  1. Promoting hand hygiene and prudent use of antimicrobials in long-term care facilities.

    PubMed

    Rummukainen, Maija; Jakobsson, Aino; Karppi, Pertti; Kautiainen, Hannu; Lyytikäinen, Outi

    2009-03-01

    A multidisciplinary team visited all long-term care facilities (n = 123) for elderly persons in the Central Finland health care district (population, 265,000) during 2004-2005. Use of alcohol-based hand rubs and ongoing systematic antimicrobials were assessed. Thereafter, regional guidelines for prudent use of antimicrobials were published. One year after the visits, a significant increase in the mean amount of alcohol-based hand rubs used was detected while usage of antimicrobials for the prevention of urinary tract reinfections had decreased.

  2. Modeling multi-scale resource selection for bear rub trees in northwestern Montana

    USGS Publications Warehouse

    Morgan Henderson, Matthew J.; Hebblewhite, Mark; Mitchell, Michael S.; Stetz, Jeffrey B.; Kendall, Katherine C.; Carlson, Ross T.

    2015-01-01

    Both black (Ursus americanus) and grizzly bears (U. arctos) are known to rub on trees and other objects, producing a network of repeatedly used and identifiable rub sites. In 2012, we used a resource selection function to evaluate hypothesized relationships between locations of 887 bear rubs in northwestern Montana, USA, and elevation, slope angle, density of open roads and distance from areas of heightened plant-productivity likely containing forage for bears. Slope and density of open roads were negatively correlated with rub presence. No other covariates were supported as explanatory variables. We also hypothesized that bear rubs would be more strongly associated with closed roads and developed trails than with game trails. The frequencies of bear rubs on 30 paired segments of developed tracks and game trails were not different. Our results suggest bear rubs may be associated with bear travel routes, and support their use as “random” sampling devices for non-invasive spatial capture–recapture population monitoring.

  3. Replication of Holograms with Corn Syrup by Rubbing

    PubMed Central

    Mejias-Brizuela, Nildia Y.; Olivares-Pérez, Arturo; Ortiz-Gutiérrez, Mauricio

    2012-01-01

    Corn syrup films are used to replicate holograms in order to fabricate micro-structural patterns without the toxins commonly found in photosensitive salts and dyes. We use amplitude and relief masks with lithographic techniques and rubbing techniques in order to transfer holographic information to corn syrup material. Holographic diffraction patterns from holographic gratings and computer Fourier holograms fabricated with corn syrup are shown. We measured the diffraction efficiency parameter in order to characterize the film. The versatility of this material for storage information is promising. Holographic gratings achieved a diffraction efficiency of around 8.4% with an amplitude mask and 36% for a relief mask technique. Preliminary results using corn syrup as an emulsion for replicating holograms are also shown in this work.

  4. The response of turbine engine rotors to interference rubs

    NASA Technical Reports Server (NTRS)

    Kascak, A. F.

    1980-01-01

    A method was developed for the direct integration of a rotor dynamics system experiencing a blade loss induced rotor rub. Both blade loss and rotor rub were simulated on a rotor typical of a small gas turbine. A small change in the coefficient of friction (from 0.1 to 0.2) caused the rotor to change from forward to backward whirl and to theoretically destroy itself in a few rotations. This method provides an analytical capability to study the susceptibility of rotors to rub induced backward whirl problems.

  5. Back to basics: hand hygiene and surgical hand antisepsis.

    PubMed

    Spruce, Lisa

    2013-11-01

    Health care-associated infections (HAIs) are a significant issue in the United States and throughout the world, but following proper hand hygiene practices is the most effective and least expensive way to prevent HAIs. Hand hygiene is inexpensive and protects patients and health care personnel alike. The four general types of hand hygiene that should be performed in the perioperative environment are washing hands that are visibly soiled, hand hygiene using alcohol-based products, surgical hand scrubs, and surgical hand scrubs using an alcohol-based surgical hand rub product. Barriers to proper hand hygiene may include not thinking about it, forgetting, skin irritation, a lack of role models, or a lack of a safety culture. One strategy for improving hand hygiene practices is monitoring hand hygiene as part of a quality improvement project, but the most important aspect for perioperative team members is to set an example for other team members by following proper hand hygiene practices and reminding each other to perform hand hygiene. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  6. Field experiences with rub induced instabilities in turbomachinery

    NASA Technical Reports Server (NTRS)

    Goggin, D. G.

    1982-01-01

    Rotordynamic instability problems are not uncommon in high speed industrial turbomachinery. One type of the many destabilizing forces that can occur is caused by a rub between the stationary and rotating parts. Descriptions are given of several cases of rub induced instabilities. Included in the descriptions are the conditions at onset, the whirl frequency and direction, and the steps taken to eliminate the problem.

  7. Behaviour modification in the management of chronic habits of abnormal eye rubbing.

    PubMed

    McMonnies, Charles W

    2009-04-01

    To describe how and why many keratoconus patients do not comply with strong advice to control chronic habits of abnormal rubbing. To outline a behaviour modification approach for controlling chronic habits of abnormal rubbing. Common reasons for chronic habits of abnormal rubbing have been reviewed as a basis for specifying a behavioural modification approach to habit reversal. The methods described are organized into the classic behavioural modification structure of: (1) habit awareness, (2) competing responses, (3) development of motivation, and (4) social support. This structure is supported by the application of social influence principles to achieve optimum compliance. The use of take-home written information in the form of an Abnormal Rubbing Guide is the basis for the development of motivation. Family social support is based upon a widening of the responsibility for avoiding eye rubbing to all family members. Some patients will need minimal application of these principles with patient education being sufficient intervention to achieve habit reversal. For patients with strong provocation to rubbing and/or by having a well established rubbing habit, a greater exposure to the habit reversal program described is indicated. Successful habit reversal may slow the rate of ectasia progression. Prophylactic application of the methods described for patients who are at risk for developing keratoconus, or post-laser assisted in situ keratomileusis keratectasia, may show that some forms of keratectasia are preventable.

  8. Practice of skin protection and skin care among German surgeons and influence on the efficacy of surgical hand disinfection and surgical glove perforation

    PubMed Central

    2014-01-01

    Background Surgical hand rub and healthy skin are basic requirements to prevent surgical site infections. Nevertheless, there is little knowledge about the current practice of skin protection and/or skin care products (SP/SC) using among surgeons as well as a lack of data pertaining to the influence of SP/SC on the antimicrobial efficacy of surgical hand rub. Methods A 10 weeks-survey among German surgeons as well as an experimental crossover study involving 26 participants were conducted. The immediate and sustainable efficacy (IE/SE) of surgical hand rub and participants’ hand moisture were measured after an 8-day usage of SP/SC, as well as the influence on micro-perforations on surgical gloves. Results The questionnaire was available to 16,000 German surgeons. Thereof, 1,771 surgeons accessed the questionnaire, representing a total participation rate of 11%. As 19% (n = 338) of questionnaires were incomplete, a total of 1,433 completed questionnaires were available for further analysis. More than 75% of the participants stated not to use any SP/SC, yet, almost 50% suffered from skin irritation or discomfort. Only 5% used SP/SC at the beginning of their shift. 10% refused to use SP/SC because of concerns that SP/SC may reduce the antimicrobial efficacy of surgical hand rub. After usage of SP/SC over 8-days, skin moisture was significantly higher (P < 0.001), whereas no significant influence on the antimicrobial efficacy of surgical hand rub was observed (IE: P = 0.135; SP: P = 0.681). Micro-perforations were detected in 8/52 surgical gloves (15%), with no statistical significant difference between SP/SC users (n = 2/26; 8%) and non-users (n = 6/26; 23%; P = 0.249). Conclusions Following the results of this largest questionnaire base survey among German surgeons on skin care, there is a need to educate and inform surgeons on the correct application and the concept of SP/SC strategies. In the present study, the combination of selected

  9. Multicenter intervention program to increase adherence to hand hygiene recommendations and glove use and to reduce the incidence of antimicrobial resistance.

    PubMed

    Trick, William E; Vernon, Michael O; Welbel, Sharon F; Demarais, Patricia; Hayden, Mary K; Weinstein, Robert A

    2007-01-01

    To determine whether a multimodal intervention could improve adherence to hand hygiene and glove use recommendations and decrease the incidence of antimicrobial resistance in different types of healthcare facilities. Prospective, observational study performed from October 1, 1999, through December 31, 2002. We monitored adherence to hand hygiene and glove use recommendations and the incidence of antimicrobial-resistant bacteria among isolates from clinical cultures. We evaluated trends in and predictors for adherence and preferential use of alcohol-based hand rubs, using multivariable analyses. Three intervention hospitals (a 660-bed acute and long-term care hospital, a 120-bed community hospital, and a 600-bed public teaching hospital) and a control hospital (a 700-bed university teaching hospital).Intervention. At the intervention hospitals, we introduced or increased the availability of alcohol-based hand rub, initiated an interactive education program, and developed a poster campaign; at the control hospital, we only increased the availability of alcohol-based hand rub. We observed 6,948 hand hygiene opportunities. The frequency of hand hygiene performance or glove use significantly increased during the study period at the intervention hospitals but not at the control hospital; the maximum quarterly frequency of hand hygiene performance or glove use at intervention hospitals (74%, 80%, and 77%) was higher than that at the control hospital (59%). By multivariable analysis, preferential use of alcohol-based hand rubs rather than soap and water for hand hygiene was more likely among workers at intervention hospitals compared with nonintervention hospitals (adjusted odds ratio, 4.6 [95% confidence interval, 3.3-6.4]) and more likely among physicians (adjusted odds ratio, 1.4 [95% confidence interval, 1.2-1.8]) than among nurses at intervention hospitals. A significantly reduced incidence of antimicrobial-resistant bacteria among isolates from clinical culture was

  10. The Snowball Blizzard Incident: A Reality Rub Life Space Interview.

    ERIC Educational Resources Information Center

    Long, Nicholas J.; Pinciotti, Dennis

    1992-01-01

    Focuses on Reality Rub Interview, one type of Life Space Interview (LSI), effective intervention strategy for use during crisis work with troubled students. Presents actual Reality Rub Interview, used with students who have "social blindness, social myopia, and tunnel vision" and who, when upset, misinterpret words and behaviors of…

  11. The Role of RUB (related to ubiquitin) Family of Proteins in the Hormone Response. Final Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Callis, Judy

    2013-03-22

    The Rub pathway is a conserved protein modification pathway. RUB (called Rubp1 in budding yeast, Nedd8 in animals and RUB in plants) is a ubiquitin-like 76-amino acid protein. It covalently attaches to protein using an enzymatic machinery analogous to the enzymes that attach ubiquitin to its substrate proteins. However, the nature of the complement of Rub-modified proteins in organisms was not clear. From bioinformatics analyses, one can identify a Rub activating enzymes and Rub conjugating enzymes. However, in many cases, their biochemical properties were not described. In DOE-funded work, we made major advances in our understanding of the Rub pathwaymore » in yeast and plants, work that is applicable to other organisms as well. There is a multi-subunit enzyme called SCF in all eukaryotes. The SCF consists of several subunits that serve as a scaffold (the cullin, SKP and RBX subunits) and one subunit that interacts with the substrate. This cullin protein (called Cdc53p in yeast and CULLIN 1 in plants and animals) was a known Rub target. In this work, we identified additional Rub targets in yeast as the other cullin-like proteins Cul3p and Rtt101p. Additionally we described the conservation of the Rub pathway because plant RUB1 can conjugated to yeast Cdc53p- in yeast. In the model plant Arabidopsis thaliana, we characterized the Rub activating enzymes and showed that they are not biochemically equivalent. We also showed that the Rub pathway is essential in plants and characterized plants with reduced levels of rub proteins. These plants are affected in multiple developmental processes. We discovered that they over-produce ethylene as dark-grown seedlings. We characterized a mutant allele of CULLIN1 in Arabidopsis with impaired interaction with RBX and showed that it is unstable in vivo. We used our knowledge of monitoring protein degradation to map the degradation determinants in a plant transcription factor. Finally, we took a mass spectrometric approach to

  12. Anti-bacterial efficacy of alcoholic hand rubs in the Kenyan market, 2015.

    PubMed

    Ochwoto, Missiani; Muita, Lucy; Talaam, Keith; Wanjala, Cecilia; Ogeto, Frank; Wachira, Faith; Osman, Saida; Kimotho, James; Ndegwa, Linus

    2017-01-01

    Hand hygiene is known to be effective in preventing hospital and community-acquired infections. The increasing number of hand sanitizer brands in Kenyan hospitals and consumer outlets is of concern. Thus the main aim of this study was to evaluate the anti-bacterial efficacy and organoleptic properties of these hand sanitizers in Kenya. This was an experimental, laboratory-based study of 14 different brands of hand sanitizers (coded HS1-14) available in various retail outlets and hospitals in Kenya. Efficacy was evaluated using standard non-pathogenic Escherichia coli (ATCC 25922), Staphylococcus aureus (ATCC 25923) and Pseudomonas aeruginosa (ATCC 27853) as per the European Standard (EN). The logarithmic reduction factors (RF) were assessed at baseline and after treatment, and log reduction then calculated. Ten and 25 healthy volunteers participated in the efficacy and organoleptic studies respectively. Four (28.6%) hand sanitizers (HS12, HS9, HS13 and HS14) showed a 5.9 reduction factor on all the three bacteria strains. Seven (50%) hand sanitizers had efficacies of <3 against all the three bacteria strains used. Efficacy on E. Coli was higher compared to the other pathogens. Three hand sanitizers were efficacious on one of the pathogens and not the other. In terms of organoleptic properties, gel-based formulations were rated far higher than the liquid based formulations brands. Fifty percent (50%) of the selected hand sanitizers in the Kenyan market have efficacy that falls below the World Health Organization (WHO) and DIN EN 1500:2013. Of the 14 hand sanitizers found in the Kenyan market, only four showed efficacies that were comparable to the WHO-formulation. There is a need to evaluate how many of these products with <3 efficacy that have been incorporated into the health system for hand hygiene and the country's policy on regulations on their usage.

  13. Rub tolerant shroud

    NASA Technical Reports Server (NTRS)

    Lenahan, Dean T. (Inventor); Gay, Jr., Charles H. (Inventor)

    1985-01-01

    A seal structure between first and second relatively moveable members for preventing gas flow in the space between the members and transverse to their general direction of motion is disclosed. The seal structure includes a plurality of substantially parallel strips within 30.degree. of normal to the radial plane generally containing these first and second relatively moveable members. The strips are thin and closely spaced and arranged so that one strip edge is attached to the first member and another edge is free to resiliently deflect when in rubbing contact with the second member.

  14. Hand hygiene in rural Indonesian healthcare workers: barriers beyond sinks, hand rubs and in-service training.

    PubMed

    Marjadi, B; McLaws, M-L

    2010-11-01

    Few attempts to increase healthcare workers' hand hygiene compliance have included an in-depth analysis of the social and behavioural context in which hand hygiene is not undertaken. We used a mixed method approach to explore hand hygiene barriers in rural Indonesian healthcare facilities to develop a resource-appropriate adoption of international guidelines. Two hospitals and eight clinics (private and public) in a rural Indonesian district were studied for three months each. Hand hygiene compliance was covertly observed for two shifts each in three adult wards at two hospitals. Qualitative data were collected from direct observation, focus group discussions and semistructured in-depth and informal interviews within healthcare facilities and the community. Major barriers to compliance included longstanding water scarcity, tolerance of dirtiness by the community and the healthcare organisational culture. Hand hygiene compliance was poor (20%; 57/281; 95% CI: 16-25%) and was more likely to be undertaken after patient contact (34% after-patient contact vs 5% before-patient contact, P<0.001) and 'inherent' opportunities associated with contacts perceived to be dirty (49% 'inherent' vs 11% 'elective' opportunities associated with clean contacts, P<0.001). Clinicians frequently touched patients without hand hygiene, and some clinicians avoided touching patients altogether. The provision of clean soap and water and in-service training will not overcome strong social and behavioural barriers unless interventions focus on long term community education and managerial commitment to the provision of supportive working conditions. Copyright © 2010 The Hospital Infection Society. All rights reserved.

  15. Effect of eye rubbing on signs and symptoms of allergic conjunctivitis in cat-sensitive individuals.

    PubMed

    Raizman, M B; Rothman, J S; Maroun, F; Rand, W M

    2000-12-01

    To evaluate the effect of eye rubbing on signs and symptoms of allergic conjunctivitis in cat-sensitive individuals. Two prospective, nonrandomized comparative studies. Thirteen patients in the first study and 20 patients in the second study with a documented history of acute allergic conjunctivitis induced by exposure to cats were enrolled. In the first trial, all patients had one eye rubbed 15 times by the investigator without exposure to airborne allergens. Both eyes were evaluated after 5, 15, 30, and 60 minutes using subject questionnaires and slit-lamp examination. At least 1 week later, each patient was exposed to cat dander for 75 minutes; 15 minutes after entering the cat room, each patient had one eye rubbed 15 times by the examiner. Subjects' eyes were then evaluated using questionnaires and slit-lamp examination. In the second trial, the visits were identical to the first trial, except that the rubbed eye in each visit was rubbed 20 times and with more force, and that patients wore masks during exposure to cat dander. In both studies, the difference between patients' rubbed and nonrubbed eyes with respect to ocular itching, chemosis, and hyperemia was noted 5, 15, 30, and 60 minutes after controlled eye rubbing. Without exposure to the cat room, rubbed eyes exhibited increased itching at 5 minutes in both studies and at 15 minutes in the second study (P < 0.05), increased chemosis at 5 and 15 minutes in the second study (P < 0.05), and increased hyperemia at 5 minutes in the second study (P < 0.05) compared with nonrubbed eyes. During exposure to cat dander, rubbed eyes consistently exhibited increased itching at 5, 15, and 30 minutes in the first and second study as well as at 60 minutes in the second study compared with nonrubbed eyes. Furthermore, during exposure to cat dander, rubbed eyes consistently exhibited increased chemosis at 5 and 15 minutes (P < 0.05) and increased hyperemia at 5, 15, and 30 minutes (P < 0.05) in the second study compared

  16. Light and short arc rubs in rotating machines: Experimental tests and modelling

    NASA Astrophysics Data System (ADS)

    Pennacchi, P.; Bachschmid, N.; Tanzi, E.

    2009-10-01

    Rotor-to-stator rub is a non-linear phenomenon which has been analyzed many times in rotordynamics literature, but very often these studies are devoted simply to highlight non-linearities, using very simple rotors, rather than to present reliable models. However, rotor-to-stator rub is actually one of the most common faults during the operation of rotating machinery. The frequency of its occurrence is increasing due to the trend of reducing the radial clearance between the seal and the rotor in modern turbine units, pumps and compressors in order to increase efficiency. Often the rub occurs between rotor and seals and the analysis of the phenomenon cannot set aside the consideration of the different relative stiffness. This paper presents some experimental results obtained by means of a test rig in which rub conditions of real machines are reproduced. In particular short arc rubs are considered and the shaft is stiffer than the obstacle. Then a model, suitable to be employed for real rotating machinery, is presented and the simulations obtained are compared with the experimental results. The model is able to reproduce the behaviour of the test rig.

  17. Improving hand hygiene in a paediatric hospital: a multimodal quality improvement approach.

    PubMed

    Jamal, Ahmed; O'Grady, G; Harnett, E; Dalton, D; Andresen, D

    2012-02-01

    Effective hand hygiene has long been recognised as an important way to reduce the transmission of bacterial and viral pathogens in healthcare settings. However, many studies have shown that adherence to hand hygiene remains low, and improvement efforts have often not delivered sustainable results. The Children's Hospital at Westmead is the largest tertiary paediatric hospital in Sydney, Australia. The hospital participated in a state-wide 'Clean hands save lives' campaign which was initiated in 2006. Strong leadership, good stakeholder engagement, readily accessible alcohol-based hand rub at the point of patient care, a multifaceted education programme, monitoring of staff, adherence to recommended hand hygiene practices and contemporaneous feedback of performance data have significantly improved and maintained compliance with hand hygiene. Hand hygiene compliance has increased from 23% in 2006 to 87% in 2011 (p<0.001). Sustained improvement in compliance with hand hygiene has been evident in the last 4 years. A decline in a set of hospital-acquired infections (including rotavirus, multiresistant organism transmission, and nosocomial bacteraemia) has also been noted as hand hygiene rates have improved. Monthly usage of alcohol-based hand rub has increased from 16 litres/1000 bed days to 51 litres/1000 bed days during this same period. This project has delivered sustained improvement in hand hygiene compliance by establishing a framework of multimodal evidence-based strategies.

  18. Three years of national hand hygiene campaign in Germany: what are the key conclusions for clinical practice?

    PubMed

    Reichardt, C; Königer, D; Bunte-Schönberger, K; van der Linden, P; Mönch, N; Schwab, F; Behnke, M; Gastmeier, P

    2013-02-01

    The World Health Organization (WHO) started the 'Clean Care is Safer Care' campaign in 2005. Since then, more than 120 countries have pledged to improve hand hygiene as a keystone of their national or subnational healthcare-associated infection prevention programmes. Thirty-eight countries have implemented national campaigns. Germany started a national campaign to improve hand hygiene compliance on 1 January 2008. The campaign, 'AKTION Saubere Hände', is funded by the German Ministry of Health and was initiated by the National Reference Centre for the Surveillance of Nosocomial Infections, the Society for Quality Management in Health Care and the German Coalition for Patient Safety. The campaign is designed as a multi-modal campaign based on the WHO implementation strategy. Since the end of 2010, more than 700 healthcare institutions have been actively participating in the campaign, among which are 28 university hospitals. Voluntarily participating hospitals have to implement the following measures: active support by hospital administrators of local campaign implementation, participation in a one-day introductory course, education of healthcare workers at least once a year, measurement of alcohol-based hand-rub consumption (AHC) and feedback on resulting data, implementation of the WHO 'My Five Moments for Hand Hygiene' model, increase in hand-rub availability, participation in national hand hygiene day at least every two years, and participation in national campaign network workshops at least once every two years. Observational studies to measure hand hygiene compliance are optional. Overall, there has been a significant increase of 11% in hand hygiene compliance in 62 hospitals that observed compliance before and after intervention. A total of 129 hospitals provided AHC data for three years and achieved an overall increase of 30.7%. The availability of alcohol-based hand rub increased from 86.8% to > 100% in intensive care units and from 63.6% to 91.3% in non

  19. Hand hygiene in the nursery during diaper changing.

    PubMed

    Phang, Koh Ni; Maznin, Nur Liyanna; Yip, Wai Kin

    2012-12-01

    This project aimed to improve hand hygiene practice during diaper changing among nurses working in the nursery. This project was conducted in one of the nurseries in a 935-bed acute care hospital with a sample of 15 nurses. A pre- and post-intervention audit was conducted utilising the Joanna Briggs Institute Practical Application of Clinical Evidence System and Getting Research into Practice module. A revised written workflow, which specified the occasions and process for hand hygiene during diaper changing, was introduced. Modifications to the baby bassinets and nursery were made after barriers to good hand hygiene were identified. The project was carried out over 4 months, from March to June 2011. The post-intervention audit results show an improvement in performing hand washing after changing diapers (20%) and performing the correct steps of hand rubbing (25%). However, the compliance rates decreased for the other criteria that measured whether hand rubbing or hand washing was performed prior to contacting the infant and after wrapping the infant, and whether hand washing was performed correctly. The improvement in compliance with hand washing--the main focus of the new workflow--after changing diapers was especially significant. The results indicated that having a workflow on the occasions and process for hand hygiene during diaper changing was useful in standardising practice. Pre- and post-implementation audits were effective methods for evaluating the effect of translating evidence into practice. However, this project had limited success in improving compliance with hand hygiene. This suggested that more effort is needed to reinforce the importance of hand hygiene and compliance to the proposed workflow. In addition, this project showed that for change to take place successfully, environmental modifications, increased awareness and adequate communication to every staff member are essential. © 2012 The Authors. International Journal of Evidence

  20. Less and less-influence of volume on hand coverage and bactericidal efficacy in hand disinfection.

    PubMed

    Kampf, Günter; Ruselack, Sigunde; Eggerstedt, Sven; Nowak, Nicolas; Bashir, Muhammad

    2013-10-10

    Some manufacturers recommend using 1.1 mL per application of alcohol-based handrubs for effective hand disinfection. However, whether this volume is sufficient to cover both hands, as recommended by the World Health Organization, and fulfills current efficacy standards is unknown. This study aimed to determine hand coverage for three handrubs (two gels based on 70% v/v and 85% w/w ethanol and a foam based on 70% v/v ethanol) applied at various volumes. Products were tested at product volumes of 1.1 mL, 2 mL, 2.4 mL as well as 1 and 2 pump dispenser pushes; the foam product was tested in addition at foam volumes of 1.1 mL, 2 mL, and 2.4 mL. Products were supplemented with a fluorescent dye and 15 participants applied products using responsible application techniques without any specific steps but the aim of completely covering both hands. Coverage quality was determined under ultraviolet light by two blinded investigators. Efficacy of the three handrubs was determined according to ASTM E 1174-06 and ASTM E 2755-10. For each experiment, the hands of 12 participants were contaminated with Serratia marcescens and the products applied as recommended (1.1 mL for 70% v/v ethanol products; 2 mL for the 85% w/w ethanol product). Log10-reduction was calculated. Volumes < 2 mL yielded high rates of incomplete coverage (67%-87%) whereas volumes ≥ 2 mL gave lower rates (13%-53%). Differences in coverage were significant between the five volumes tested for all handrubs (p < 0.001; two-way ANOVA) but not between the three handrubs themselves (p = 0.796). Application of 1.1 mL of 70% v/v ethanol rubs reduced contamination by 1.85 log10 or 1.60 log10 (ASTM E 1174-06); this failed the US FDA efficacy requirement of at least 2 log10. Application of 2 mL of the 85% w/w ethanol rub reduced contamination by 2.06 log10 (ASTM E 1174-06), fulfilling the US FDA efficacy requirement. Similar results were obtained according to ASTM E 2755-10. Our data indicated that

  1. Less and less–influence of volume on hand coverage and bactericidal efficacy in hand disinfection

    PubMed Central

    2013-01-01

    Background Some manufacturers recommend using 1.1 mL per application of alcohol-based handrubs for effective hand disinfection. However, whether this volume is sufficient to cover both hands, as recommended by the World Health Organization, and fulfills current efficacy standards is unknown. This study aimed to determine hand coverage for three handrubs (two gels based on 70% v/v and 85% w/w ethanol and a foam based on 70% v/v ethanol) applied at various volumes. Methods Products were tested at product volumes of 1.1 mL, 2 mL, 2.4 mL as well as 1 and 2 pump dispenser pushes; the foam product was tested in addition at foam volumes of 1.1 mL, 2 mL, and 2.4 mL. Products were supplemented with a fluorescent dye and 15 participants applied products using responsible application techniques without any specific steps but the aim of completely covering both hands. Coverage quality was determined under ultraviolet light by two blinded investigators. Efficacy of the three handrubs was determined according to ASTM E 1174-06 and ASTM E 2755-10. For each experiment, the hands of 12 participants were contaminated with Serratia marcescens and the products applied as recommended (1.1 mL for 70% v/v ethanol products; 2 mL for the 85% w/w ethanol product). Log10-reduction was calculated. Results Volumes < 2 mL yielded high rates of incomplete coverage (67%–87%) whereas volumes ≥ 2 mL gave lower rates (13%–53%). Differences in coverage were significant between the five volumes tested for all handrubs (p < 0.001; two-way ANOVA) but not between the three handrubs themselves (p = 0.796). Application of 1.1 mL of 70% v/v ethanol rubs reduced contamination by 1.85 log10 or 1.60 log10 (ASTM E 1174-06); this failed the US FDA efficacy requirement of at least 2 log10. Application of 2 mL of the 85% w/w ethanol rub reduced contamination by 2.06 log10 (ASTM E 1174-06), fulfilling the US FDA efficacy requirement. Similar results were obtained according to ASTM E 2755

  2. Effects of geometric variables on rub characteristics of Ti-6Al-4V

    NASA Technical Reports Server (NTRS)

    Bill, R. C.; Wolak, J.; Wisander, D. W.

    1981-01-01

    Experiments simulating rub interactions between Ti-6Al-4V blade tips and various seal materials were conducted. The number of blade tips and the blade tip geometry were varied to determine their effects on rub forces and on wear phenomena. Contact was found to be quite unsteady for all blade tip geometries except for those incorporating deliberately rounded blade tips. The unsteady contact was characterized by long periods of rubbing contact and increasing blade tip that terminated in sudden rapid metal removal, sometimes accompanied by tearing and disruption of porous seal material under the rub surface. A model describing the blade tip loading is proposed and is based on the propagation of an elastic stress wave through the seal material as the seal material is dynamically compressed by the blade tip leading edge.

  3. Rotor-to-stator Partial Rubbing and Its Effects on Rotor Dynamic Response

    NASA Technical Reports Server (NTRS)

    Muszynska, Agnes; Franklin, Wesley D.; Hayashida, Robert D.

    1991-01-01

    Results from experimental and analytical studies on rotor to stationary element partial rubbings at several locations and their effects on rotor dynamic responses are presented. The mathematical model of a rubbing rotor is given. The computer program provides numerical results which agree with experimentally obtained rotor responses.

  4. A comparison of hand washing techniques to remove Escherichia coli and caliciviruses under natural or artificial fingernails.

    PubMed

    Lin, Chia-Min; Wu, Fone-Mao; Kim, Hoi-Kyung; Doyle, Michael P; Michael, Barry S; Williams, L Keoki

    2003-12-01

    Compared with other parts of the hand, the area beneath fingernails harbors the most microorganisms and is most difficult to clean. Artificial fingernails, which are usually long and polished, reportedly harbor higher microbial populations than natural nails. Hence, the efficacy of different hand washing methods for removing microbes from natural and artificial fingernails was evaluated. Strains of nonpathogenic Escherichia coli JM109 and feline calicivirus (FCV) strain F9 were used as bacterial and viral indicators, respectively. Volunteers with artificial or natural nails were artificially contaminated with ground beef containing E. coli JM109 or artificial feces containing FCV. Volunteers washed their hands with tap water, regular liquid soap, antibacterial liquid soap, alcohol-based hand sanitizer gel, regular liquid soap followed by alcohol gel, or regular liquid soap plus a nailbrush. The greatest reduction of inoculated microbial populations was obtained by washing with liquid soap plus a nailbrush, and the least reduction was obtained by rubbing hands with alcohol gel. Lower but not significantly different (P > 0.05) reductions of E. coli and FCV counts were obtained from beneath artificial than from natural fingernails. However, significantly (P < or = 0.05) higher E. coli and FCV counts were recovered from hands with artificial nails than from natural nails before and after hand washing. In addition, microbial cell numbers were correlated with fingernail length, with greater numbers beneath fingernails with longer nails. These results indicate that best practices for fingernail sanitation of food handlers are to maintain short fingernails and scrub fingernails with soap and a nailbrush when washing hands.

  5. Two- versus four-handed techniques for endonasal resection of orbital apex tumors.

    PubMed

    Craig, John R; Lee, John Y K; Petrov, Dmitriy; Mehta, Sonul; Palmer, James N; Adappa, Nithin D

    2015-01-01

    Open versus endonasal resection of orbital apex (OA) tumors is generally based on tumor size, location, and pathology. For endonasal resection, two- and four-handed techniques have been reported, but whether one technique is more optimal based on these tumor features has not been evaluated. To determine whether two- versus four-handed techniques result in better outcomes after endoscopic resection of OA tumors, and whether either technique is better suited for intra- versus extraconal location and for benign versus malignant pathology. A retrospective review of all expanded endonasal approaches for OA tumors was performed at a single institution from 2009 to 2013. A PubMed database search was also performed to review series published on endonasal OA tumor resection. Across all the cases reviewed, the following data were recorded: two- versus four-handed techniques, intra- versus extraconal tumor location, and benign versus malignant pathology. The relationship between these variables and resection extent was analyzed by the Fisher exact test. Postoperative visual status and complications were also reviewed. Ten cases from the institution and 94 cases from 17 publications were reviewed. Both two- and four-handed techniques were used to resect extra- and intraconal OA tumors, for both benign and malignant pathology. Four-handed techniques included a purely endonasal approach and a combined endonasal-orbital approach. On univariate analysis, the strongest predictor of complete resection was benign pathology (p = 0.005). No significant difference was found between the extent of resection and a two- versus a four-handed technique. Visual status was improved or unchanged in 94% of cases, and other complications were rare. Benign tumors that involve the medial extraconal and posterior inferomedial intraconal OA can be treated by either two- or four-handed endonasal techniques. Selecting two- versus four-handed techniques and endonasal versus endonasal-orbital four-handed

  6. An experimental investigation of rubbing interaction in labyrinth seals at cryogenic temperature

    NASA Technical Reports Server (NTRS)

    Dolan, F. X.; Kennedy, F. E.; Schulson, E. M.

    1985-01-01

    An experimental program was carried out to address issues related to the observed cracking of the titanium knife edges on the labyrinth seals of the high pressure fuel pump (HPFP) in the Space Shuttle main engine (SSME). Thermal shock experiments were carried out using a jet specimen with geometry similar to the knife edge geometry. These tests demonstrate that cracking of the titanium alloy is possible in a situation involving repeated thermal cycles over a wide temperature range, as might be realized during a rub in the liquid hydrogen fuel pump. High speed rub interaction tests were conducted using a representative knife edge and seal geometry over a broad range of interaction rates. Alternative materials were also experimentally evaluated. These tests provide information which can be used to design improved labyrinth seals for the HPFP of the SSME. In particular, plasma-sprayed aluminum-graphite was found to be significantly better than aluminum alloy seals used at present from the standpoint of rub performance. Ion nitriding of the titanium alloy knife edges was also found to improve rub performance compared with the untreated baseline knife edge material.

  7. [Hand hygiene technique assessment using electronic equipment in 26 Hungarian healthcare institutions].

    PubMed

    Lehotsky, Ákos; Morvai, Júlia; Szilágyi, László; Bánsághi, Száva; Benkó, Alíz; Haidegger, Tamás

    2017-07-01

    Hand hygiene is probably the most effective tool of nosocomial infection prevention, however, proper feedback and control is needed to develop the individual hand hygiene practice. Assessing the efficiency of modern education tools, and digital demonstration and verification equipment during their wide-range deployment. 1269 healthcare workers took part in a training organized by our team. The training included the assessment of the participants' hand hygiene technique to identify the most often missed areas. The hand hygiene technique was examined by a digital device. 33% of the participants disinfected their hands incorrectly. The most often missed sites are the fingertips (33% on the left hand, 37% on the right hand) and the thumbs (42% on the left hand, 32% on the right hand). The feedback has a fundamental role in the development of the hand hygiene technique. With the usage of electronic devices feedback can be provided efficiently and simply. Orv Hetil. 2017; 158(29): 1143-1148.

  8. An automated hand hygiene training system improves hand hygiene technique but not compliance.

    PubMed

    Kwok, Yen Lee Angela; Callard, Michelle; McLaws, Mary-Louise

    2015-08-01

    The hand hygiene technique that the World Health Organization recommends for cleansing hands with soap and water or alcohol-based handrub consists of 7 poses. We used an automated training system to improve clinicians' hand hygiene technique and test whether this affected hospitalwide hand hygiene compliance. Seven hundred eighty-nine medical and nursing staff volunteered to participate in a self-directed training session using the automated training system. The proportion of successful first attempts was reported for each of the 7 poses. Hand hygiene compliance was collected according to the national requirement and rates for 2011-2014 were used to determine the effect of the training system on compliance. The highest pass rate was for pose 1 (palm to palm) at 77% (606 out of 789), whereas pose 6 (clean thumbs) had the lowest pass rate at 27% (216 out of 789). One hundred volunteers provided feedback to 8 items related to satisfaction with the automated training system and most (86%) expressed a high degree of satisfaction and all reported that this method was time-efficient. There was no significant change in compliance rates after the introduction of the automated training system. Observed compliance during the posttraining period declined but increased to 82% in response to other strategies. Technology for training clinicians in the 7 poses played an important education role but did not affect compliance rates. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  9. Rubbing time and bonding performance of one-step adhesives to primary enamel and dentin.

    PubMed

    Botelho, Maria Paula Jacobucci; Isolan, Cristina Pereira; Schwantz, Júlia Kaster; Lopes, Murilo Baena; Moraes, Rafael Ratto de

    2017-01-01

    This study investigated whether increasing the concentration of acidic monomers in one-step adhesives would allow reducing their application time without interfering with the bonding ability to primary enamel and dentin. Experimental one-step self-etch adhesives were formulated with 5 wt% (AD5), 20 wt% (AD20), or 35 wt% (AD35) acidic monomer. The adhesives were applied using rubbing motion for 5, 10, or 20 s. Bond strengths to primary enamel and dentin were tested under shear stress. A commercial etch-and-rinse adhesive (Single Bond 2; 3M ESPE) served as reference. Scanning electron microscopy was used to observe the morphology of bonded interfaces. Data were analysed at p<0.05. In enamel, AD35 had higher bond strength when rubbed for at least 10 s, while application for 5 s generated lower bond strength. In dentin, increased acidic monomer improved bonding only for 20 s rubbing time. The etch-and-rinse adhesive yielded higher bond strength to enamel and similar bonding to dentin as compared with the self-etch adhesives. The adhesive layer was thicker and more irregular for the etch-and-rinse material, with no appreciable differences among the self-etch systems. Overall, increasing the acidic monomer concentration only led to an increase in bond strength to enamel when the rubbing time was at least 10 s. In dentin, despite the increase in bond strength with longer rubbing times, the results favoured the experimental adhesives compared to the conventional adhesive. Reduced rubbing time of self-etch adhesives should be avoided in the clinical setup.

  10. A technique for fast and accurate measurement of hand volumes using Archimedes' principle.

    PubMed

    Hughes, S; Lau, J

    2008-03-01

    A new technique for measuring hand volumes using Archimedes principle is described. The technique involves the immersion of a hand in a water container placed on an electronic balance. The volume is given by the change in weight divided by the density of water. This technique was compared with the more conventional technique of immersing an object in a container with an overflow spout and collecting and weighing the volume of overflow water. The hand volume of two subjects was measured. Hand volumes were 494 +/- 6 ml and 312 +/- 7 ml for the immersion method and 476 +/- 14 ml and 302 +/- 8 ml for the overflow method for the two subjects respectively. Using plastic test objects, the mean difference between the actual and measured volume was -0.3% and 2.0% for the immersion and overflow techniques respectively. This study shows that hand volumes can be obtained more quickly than the overflow method. The technique could find an application in clinics where frequent hand volumes are required.

  11. Antibacterial Efficacy of Several Surgical Hand Preparation Products Used by Veterinary Students.

    PubMed

    Chou, Po-Yen; Doyle, Aimie J; Arai, Shiori; Burke, Pierre J; Bailey, Trina R

    2016-05-01

    To compare the antibacterial efficacy of different surgical hand antisepsis protocols used by veterinary students. Prospective, randomized, controlled study. Third year veterinary students (n=45). The participants were randomly assigned to 4 of the following 12 hand preparation product/time combinations: nonabrasive hand scrub method with 4% chlorhexidine gluconate (CH); hand rub with a mixture of 30% 1-propanol and 45% 2-propanol solution (MPS), 70% 2-propanol solution (IPS), or 61% ethanol solution with 1% chlorhexidine gluconate (ES/CH), with a contact time of 1.5, 3, or 5 minutes. Antibacterial efficacy was assessed after surgical hand preparation and at the end of surgery. Log reductions of total bacterial colony forming unit (CFU)/mL and positive aerobic culture rates were compared using multivariable analysis of variance and multivariable logistic regression, respectively. After surgical hand preparation, CH and ES/CH provided significantly higher log CFU reduction and lower positive culture rate for Gram-positive and spore-forming bacteria compared to MPS and IPS. Increase in contact time did not provide significant improvement in bacterial reduction. At the end of surgery, ES/CH provided significantly higher log CFU reduction compared to IPS and lower positive culture rate for Gram-positive bacteria compared to CH, MPS, and IPS. Increase in contact time significantly improved log CFU reduction in ES/CH and MPS groups. In our population of veterinary students ES/CH hand rubs or CH scrubs were more effective in reducing bacterial CFU during surgical hand preparation than MPS or IPS. © Copyright 2016 by The American College of Veterinary Surgeons.

  12. Rubbing time and bonding performance of one-step adhesives to primary enamel and dentin

    PubMed Central

    Botelho, Maria Paula Jacobucci; Isolan, Cristina Pereira; Schwantz, Júlia Kaster; Lopes, Murilo Baena; de Moraes, Rafael Ratto

    2017-01-01

    Abstract Objectives: This study investigated whether increasing the concentration of acidic monomers in one-step adhesives would allow reducing their application time without interfering with the bonding ability to primary enamel and dentin. Material and methods: Experimental one-step self-etch adhesives were formulated with 5 wt% (AD5), 20 wt% (AD20), or 35 wt% (AD35) acidic monomer. The adhesives were applied using rubbing motion for 5, 10, or 20 s. Bond strengths to primary enamel and dentin were tested under shear stress. A commercial etch-and-rinse adhesive (Single Bond 2; 3M ESPE) served as reference. Scanning electron microscopy was used to observe the morphology of bonded interfaces. Data were analysed at p<0.05. Results: In enamel, AD35 had higher bond strength when rubbed for at least 10 s, while application for 5 s generated lower bond strength. In dentin, increased acidic monomer improved bonding only for 20 s rubbing time. The etch-and-rinse adhesive yielded higher bond strength to enamel and similar bonding to dentin as compared with the self-etch adhesives. The adhesive layer was thicker and more irregular for the etch-and-rinse material, with no appreciable differences among the self-etch systems. Conclusion: Overall, increasing the acidic monomer concentration only led to an increase in bond strength to enamel when the rubbing time was at least 10 s. In dentin, despite the increase in bond strength with longer rubbing times, the results favoured the experimental adhesives compared to the conventional adhesive. Reduced rubbing time of self-etch adhesives should be avoided in the clinical setup. PMID:29069150

  13. Electronic and elastic properties of new semiconducting oP(12)-type RuB(2) and OsB(2).

    PubMed

    Hao, Xianfeng; Xu, Yuanhui; Gao, Faming

    2011-03-30

    Using first-principles total energy calculations we investigate the structural, elastic and electronic properties of new hypothetical oP(12)-type phase RuB(2) and OsB(2). The calculations indicate that the oP(12)-type phase RuB(2) and OsB(2) are thermodynamically and mechanically stable. Remarkably, the new phases RuB(2) and OsB(2) are predicted to be semiconductors, and the appearance of band gaps is ascribed to the enhanced B-B covalent hybridization. Compared to metallic oP(6)-type RuB(2) and OsB(2) phases, the new phases possess similar mechanical properties and hardness. The combination of the probability of tunable electronic properties, strong stiffness and high hardness make RuB(2) and OsB(2) attractive and interesting for advanced applications. © 2011 IOP Publishing Ltd

  14. Analysis on accuracy improvement of rotor-stator rubbing localization based on acoustic emission beamforming method.

    PubMed

    He, Tian; Xiao, Denghong; Pan, Qiang; Liu, Xiandong; Shan, Yingchun

    2014-01-01

    This paper attempts to introduce an improved acoustic emission (AE) beamforming method to localize rotor-stator rubbing fault in rotating machinery. To investigate the propagation characteristics of acoustic emission signals in casing shell plate of rotating machinery, the plate wave theory is used in a thin plate. A simulation is conducted and its result shows the localization accuracy of beamforming depends on multi-mode, dispersion, velocity and array dimension. In order to reduce the effect of propagation characteristics on the source localization, an AE signal pre-process method is introduced by combining plate wave theory and wavelet packet transform. And the revised localization velocity to reduce effect of array size is presented. The accuracy of rubbing localization based on beamforming and the improved method of present paper are compared by the rubbing test carried on a test table of rotating machinery. The results indicate that the improved method can localize rub fault effectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Outbreaks where food workers have been implicated in the spread of foodborne disease. Part 9. Washing and drying of hands to reduce microbial contamination.

    PubMed

    Todd, Ewen C D; Michaels, Barry S; Smith, Debra; Greig, Judy D; Bartleson, Charles A

    2010-10-01

    During various daily activities at home and work, hands quickly become contaminated. Some activities increase the risk of finger contamination by pathogens more than others, such as the use of toilet paper to clean up following a diarrheal episode, changing the diaper of a sick infant, blowing a nose, or touching raw food materials. Many foodborne outbreak investigation reports have identified the hands of food workers as the source of pathogens in the implicated food. The most convenient and efficient way of removing pathogens from hands is through hand washing. Important components of hand washing are potable water for rinsing and soaps to loosen microbes from the skin. Hand washing should occur after any activity that soils hands and certainly before preparing, serving, or eating food. Antimicrobial soaps are marginally more effective than plain soaps, but constant use results in a buildup of the antimicrobial compound on the skin. The time taken to wash hands and the degree of friction generated during lathering are more important than water temperature for removing soil and microorganisms. However, excessive washing and scrubbing can cause skin damage and infections. Drying hands with a towel removes pathogens first by friction during rubbing with the drying material and then by wicking away the moisture into that material. Paper rather than cloth towels should be encouraged, although single-use cloth towels are present in the washrooms of higher class hotels and restaurants. Warm air dryers remove moisture and any surface microorganisms loosened by washing from hands by evaporation while the hands are rubbed together vigorously; however, these dryers take too long for efficient use. The newer dryers with high-speed air blades can achieve dryness in 10 to 15 s without hand rubbing.

  16. A test procedure for evaluating surgical hand disinfection.

    PubMed

    Babb, J R; Davies, J G; Ayliffe, G A

    1991-06-01

    A technique for assessing the immediate and prolonged efficacy of surgical scrubs and alcoholic hand rubs is described. A mean baseline count is obtained from all volunteers and logarithmic reductions in resident skin flora immediately after one or more applications, and after wearing gloves for 3 h, are measured. Loose-fitting surgical gloves are used for sampling resident flora. Preparations were applied using a standard technique for 2 min, apart from one test with 70% isopropanol (IPA) in which the application time was 30 s. Two studies are described, one of which compared four chlorhexidine scrubs, and the second 70% IPA, 7.5% povidone-iodine scrub, 2% triclosan cleanser and unmedicated bar soap. In spite of their constituent similarity, the four chlorhexidine scrubs varied considerably in efficacy and user acceptability. A 2 min application of 70% IPA was the most effective treatment, and gave log10 reductions of 1.65 for immediate and 1.58 for prolonged effect. This was marginally more effective than a 30 s application, but the difference was not significant. 'Hibiscrub' was the most effective aqueous formulation and gave reductions of 1.01 for immediate effect and 1.16 for prolonged effect. The test described could be used by reference centres and manufacturers to assess the efficacy of new and existing surgical hand disinfection formulations.

  17. Two time-series analyses of the impact of antibiotic consumption and alcohol-based hand disinfection on the incidences of nosocomial methicillin-resistant Staphylococcus aureus infection and Clostridium difficile infection.

    PubMed

    Kaier, Klaus; Hagist, Christian; Frank, Uwe; Conrad, Andreas; Meyer, Elisabeth

    2009-04-01

    To determine the impact of antibiotic consumption and alcohol-based hand disinfection on the incidences of nosocomial methicillin-resistant Staphylococcus aureus (MRSA) infection and Clostridium difficile infection (CDI). Two multivariate time-series analyses were performed that used as dependent variables the monthly incidences of nosocomial MRSA infection and CDI at the Freiburg University Medical Center during the period January 2003 through October 2007. The volume of alcohol-based hand rub solution used per month was quantified in liters per 1,000 patient-days. Antibiotic consumption was calculated in terms of the number of defined daily doses per 1,000 patient-days per month. The use of alcohol-based hand rub was found to have a significant impact on the incidence of nosocomial MRSA infection (P< .001). The multivariate analysis (R2=0.66) showed that a higher volume of use of alcohol-based hand rub was associated with a lower incidence of nosocomial MRSA infection. Conversely, a higher level of consumption of selected antimicrobial agents was associated with a higher incidence of nosocomial MRSA infection. This analysis showed this relationship was the same for the use of second-generation cephalosporins (P= .023), third-generation cephalosporins (P= .05), fluoroquinolones (P= .01), and lincosamides (P= .05). The multivariate analysis (R2=0.55) showed that a higher level of consumption of third-generation cephalosporins (P= .008), fluoroquinolones (P= .084), and/or macrolides (P= .007) was associated with a higher incidence of CDI. A correlation with use of alcohol-based hand rub was not detected. In 2 multivariate time-series analyses, we were able to show the impact of hand hygiene and antibiotic use on the incidence of nosocomial MRSA infection, but we found no association between hand hygiene and incidence of CDI.

  18. Bilateral Glaucomatous Optic Neuropathy Caused by Eye Rubbing.

    PubMed

    Savastano, Alfonso; Savastano, Maria Cristina; Carlomusto, Laura; Savastano, Silvio

    2015-01-01

    In this report, we describe a particular condition of a 52-year-old man who showed advanced bilateral glaucomatous-like optic disc damage, even though the intraocular pressure resulted normal during all examinations performed. Visual field test, steady-state pattern electroretinogram, retinal nerve fiber layer and retinal tomographic evaluations were performed to evaluate the optic disc damage. Over a 4-year observational period, his visual acuity decreased to 12/20 in the right eye and counting fingers in the left eye. Visual fields were severely compromised, and intraocular pressure values were not superior to 14 mm Hg during routine examinations. An accurate anamnesis and the suspicion of this disease represent a crucial aspect to establish the correct diagnosis. In fact, our patient strongly rubbed his eyes for more than 10 h per day. Recurrent and continuous eye rubbing can induce progressive optic neuropathy, causing severe visual field damage similar to the pathology of advanced glaucoma.

  19. Rotor-to-stator rub vibration in centrifugal compressor

    NASA Technical Reports Server (NTRS)

    Gao, J. J.; Qi, Q. M.

    1985-01-01

    One example of excessive vibration encountered during loading of a centrifugal compressor train (H type compressor with HP casing) is discussed. An investigation was made of the effects of the dynamic load on the bearing stiffness and the rotor-bearing system critical speed. The high vibration occurred at a "threshold load," but the machine didn't run smoothly due to rubs even when it had passed through the threshold load. The acquisition and discussion of the data taken in the field as well as a description of the case history which utilizes background information to identify the malfunction conditions is presented. The analysis shows that the failures, including full reverse precession rub and exact one half subharmonic vibration, were caused by the oversize bearings and displacement of the rotor center due to foundation deformation and misalignment between gear shafts, etc. The corrective actions taken to alleviate excessive vibration and the problems which remain to be solved are also presented.

  20. Brine saturation technique for extraction of light filth from rubbed, ground, and whole sage: collaborative study.

    PubMed

    Freeman, C C

    1985-01-01

    A new approach to the isolation of light filth from the 3 commercial forms of sage was studied collaboratively. It incorporates a simple isopropanol defatting, followed by saturation of the product with brine by alternately heating and cooling, and subsequent trapping of filth from tap water with olive oil. This method circumvents the use of hazardous, expensive solvents and more time-consuming pretreatment procedures. Overall recoveries were 92.1% for rodent hair and 78.7% for insect fragments on clean, easy-to-read papers. An additional blending step was necessary to obtain satisfactory recovery of rodent hair fragments from whole sage. The method has been adopted official first action for light filth in rubbed and ground sage only.

  1. Implementing AORN recommended practices for hand hygiene.

    PubMed

    Patrick, Marcia; Van Wicklin, Sharon A

    2012-04-01

    This article focuses on implementing the revised AORN "Recommended practices for hand hygiene in the perioperative setting." The content of the document has been expanded and reorganized from the previous iteration and now includes specific activity statements about water temperature, water and soap dispensing controls, the type of dispensers to use, paper towel dispenser requirements, placement of soap and rub dispensers, and regulatory requirements for products and recommendations for hand hygiene practices. A successful hand hygiene program allows end users to have input into the selection and evaluation of products and should include educating personnel about proper hand hygiene, product composition and safety, and how and when to use specific products. Measures for competency evaluation and compliance monitoring include observations, quizzes, skills labs, electronic monitoring systems, handheld device applications, and data collection forms. Copyright © 2012 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  2. Opportunity's 'Rub al Khali' Panorama

    NASA Technical Reports Server (NTRS)

    2005-01-01

    [figure removed for brevity, see original site] Click on the image for Opportunity's 'Rub al Khali' Panorama (QTVR)

    This panoramic image, dubbed 'Rub al Khali,' was acquired by NASA's Mars Exploration Rover Opportunity on the plains of Meridiani during the period from the rover's 456th to 464th sols on Mars (May 6 to May 14, 2005). Opportunity was about 2 kilometers (1.2 miles) south of 'Endurance Crater' at a place known informally as 'Purgatory Dune.'

    The rover was stuck in the dune's deep fine sand for more than a month. 'Rub al Khali' (Arabic translation: 'the empty quarter') was chosen as the name for this panorama because it is the name of a similarly barren, desolate part of the Saudi Arabian desert on Earth.

    The view spans 360 degrees. It consists of images obtained in 97 individual pointings of the panoramic camera. The camera took images with five camera filters at each pointing. This 22,780-by-6,000-pixel mosaic is an approximately true-color rendering generated using the images acquired through filters admitting light wavelengths of 750, 530, and 480 nanometers.

    Lighting varied during the nine sols it took to acquire this panorama, resulting in some small image seams within the mosaic. These seams have been smoothed in sky parts of the mosaic to better simulate the vista that a person would see if able to view it all at the same time on Mars.

    Opportunity's tracks leading back to the north (center of the panorama) are a reminder of the rover's long trek from Endurance Crater. The deep ruts dug by Opportunity's wheels as it became stuck in the sand appear in the foreground. The crest and trough of the last ripple the rover crossed before getting stuck is visible in the center. These wind-formed sand features are only about 10 to 15 centimeters (4 to 6 inches) tall. The crest of the actual ripple where the rover got stuck can be seen just to the right of center. The tracks and a few other places on and near ripple crests can

  3. An Australian Response to Michael Bérubé

    ERIC Educational Resources Information Center

    Frances, Raelene

    2016-01-01

    This article supports Bérubé's conclusion regarding the intellectual health of humanities scholarship. However, it argues that the case of "contingent faculty"--or academics with short-term or casual contracts--is in many respects different in Australia to the situation he outlines for the US. Whilst a variety of funding pressures have…

  4. How a smiley protects health: A pilot intervention to improve hand hygiene in hospitals by activating injunctive norms through emoticons

    PubMed Central

    Tsivrikos, Dimitrios; Dollinger, Daniel; Lermer, Eva

    2018-01-01

    Hand hygiene practice in hospitals is unfortunately still widely insufficient, even though it is known that transmitting pathogens via hands is the leading cause of healthcare-associated infections. Previous research has shown that improving knowledge, providing feedback on past behaviour and targeting social norms are promising approaches to improve hand hygiene practices. The present field experiment was designed to direct people on when to perform hand hygiene and prevent forgetfulness. This intervention is the first to examine the effect of inducing injunctive social norms via an emoticon-based feedback system on hand hygiene behaviour. Electronic monitoring and feedback devices were installed in hospital patient rooms on top of hand-rub dispensers, next to the doorway, for a period of 17 weeks. In the emoticon condition, screens at the devices activated whenever a person entered or exited the room. Before using the alcohol-based hand-rub dispenser, a frowny face was displayed, indicating that hand hygiene should be performed. If the dispenser was subsequently used, this picture changed to a smiley face to positively reinforce the correct behaviour. Hand hygiene behaviour in the emoticon rooms significantly outperformed the behaviour in three other tested conditions. The strong effect in this field experiment indicates that activating injunctive norms may be a promising approach to improve hand hygiene behaviour. Theoretical and practical implications of these findings are discussed. PMID:29782516

  5. Guidelines for Mass Casualty Decontamination During a HAZMAT/Weapon of Mass Destruction Incident. Volumes 1 and 2 (Update)

    DTIC Science & Technology

    2013-08-01

    neutralization: 1. Physical removal involves mechanical action with techniques such as gentle fric- tion (such as rubbing with hands, soft non...sulfur mustard), using gen- tle friction, such as rubbing with hands, a soft cloth, or sponges is recommended to aid in re- moval of the contaminants...account for both initial mass decontamination and secondary de- contamination. Some examples include the use of colored rubber bands and specially de

  6. Theoretical and experimental investigation on the sudden unbalance and rub-impact in rotor system caused by blade off

    NASA Astrophysics Data System (ADS)

    Wang, Cun; Zhang, Dayi; Ma, Yanhong; Liang, Zhichao; Hong, Jie

    2016-08-01

    Blade loss from a running turbofan rotor will introduce sudden unbalance into the dynamical system, and as a consequence leads to the rub-impact, the asymmetry of rotor and a series of interesting dynamic characteristics. The paper focuses on the theoretical study on the sudden unbalance and rub-impact caused by blade loss, in particular investigates the response of the rotor on a rotor test rig with sudden unbalance and rub-impact device designed respectively. The results reveal that the sudden unbalance will induce impact effect on the rotor, and critical speed frequency is excited in frequency spectrum. Meantime, the impact effect is more obvious for the rotor operating above critical speed. The influence of rub-impact is considered as additional constraint to the rotor, analyzed by the theory of time-varying system for the first time, and the results are evaluated by experimental tests. The study shows that great attention should be paid to the dynamical design for the overhung rotor system, additional constraint and corresponding analysis method in rub-impact need to be intensively studied.

  7. An evaluation of hospital hand hygiene practice and glove use in Hong Kong.

    PubMed

    Chau, Janita P-C; Thompson, David R; Twinn, Sheila; Lee, Diana T F; Pang, Sharon W M

    2011-05-01

    To identify omissions in hand hygiene practice and glove use among hospital workers in Hong Kong. Hospital-acquired infection is the commonest complication affecting hospitalised patients. Even though research evidence suggests that hand hygiene and proper glove use are the most important ways to prevent the spread of disease and infection, compliance with both are reported to be unacceptably low. An observational study of hospital workers in one acute and two convalescence and rehabilitation hospitals in Hong Kong was conducted. The participating clinical areas included the medical and surgical wards, accident and emergency department and intensive care unit. Hand hygiene practice and glove use amongst 206 hospital health and support workers, stratified according to years of working experience, were observed. The number of observed episodes for hand hygiene was 1037 and for glove use 304. Compliance with hand hygiene was 74.7% and with glove use 72.4%. In approximately two-third of episodes, participants washed their hands after each patient contact; though, 78.5% failed to rub their hands together vigorously for at least 15 seconds. The major break in compliance with glove use was failure to change gloves between procedures on the same patient. In 28.6% of observed glove use episodes, participants did not wear gloves during procedures that exposed them to blood, body fluids, excretion, non-intact skin or mucous membranes. Significant differences in performance scores on antiseptic hand rub were found between the two types of hospital and on glove use between the three groups of work experience: ≤ 5, 6-10, >10 years. Education and reinforcement of proper hand hygiene practice and glove use among hospital health and support workers is needed. © 2011 Blackwell Publishing Ltd.

  8. Effects of eye rubbing on the levels of protease, protease activity and cytokines in tears: relevance in keratoconus.

    PubMed

    Balasubramanian, Sivaraman A; Pye, David C; Willcox, Mark D P

    2013-03-01

    Proteases, protease activity and inflammatory molecules in tears have been found to be relevant in the pathogenesis of keratoconus. We sought to determine the influence of eye rubbing on protease expression, protease activity and concentration of inflammatory molecules in tears. Basal tears were collected from normal volunteers before and after 60 seconds of experimental eye rubbing. The total amount of matrix metalloproteinase (MMP)-13 and inflammatory molecules interleukin (IL)-6 and tumour necrosis factor (TNF)-α in the tear samples were measured using specific enzyme-linked immunosorbent assays (ELISA). Tear collagenase activity was investigated using a specific activity assay. The concentrations of MMP-13 (51.9 ± 34.3 versus 63 ± 36.8 pg/ml, p = 0.006), IL-6 (1.24 ± 0.98 versus 2.02 ± 1.52 pg/ml, p = 0.004) and TNF-α (1.16 ± 0.74 versus 1.44 ± 0.66 pg/ml, p = 0.003) were significantly increased in normal subjects after eye rubbing. The experimental eye rub did not alter significantly the collagenase activity (5.02 ± 3 versus 7.50 ± 3.90 fluorescent intensity units, p = 0.14) of tears. Eye rubbing for 60 seconds increased the level of tear MMP-13, IL-6 and TNF-α in normal study subjects. This increase in protease, protease activity and inflammatory mediators in tears after eye rubbing may be exacerbated even further during persistent and forceful eye rubbing seen in people with keratoconus and this in turn may contribute to the progression of the disease. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  9. Severe acute corneal hydrops in a patient with Down syndrome and persistent eye rubbing.

    PubMed

    Ozcan, Altan A; Ersoz, T Reha

    2007-01-01

    We report a case of severe acute corneal hydrops in an 11-year-old boy with keratoconus associated with Down syndrome and vigorous eye rubbing. Complete resolution of the corneal edema and a central corneal scar was seen in the 8th week of final follow-up. Eye-rubbing may play a role in the pathogenesis of acute hydrops, and conventional therapy can be successful in its management, even in severe cases.

  10. Contact dermatitis to Vicks VapoRub.

    PubMed

    Noiles, Kristin; Pratt, Melanie

    2010-01-01

    Vicks VapoRub (VVR) is a commonly used inhalant ointment that helps relieve symptoms of upper respiratory tract infections. It contains several plant substances, including turpentine oil, eucalyptus oil, and cedar leaf oil, which can potentially irritate or sensitize the skin, as well as camphor, menthol, nutmeg oil, and thymol. Although many reports describe allergic contact dermatitis (ACD) to the various constituents in VVR ointment, there are no cases of VVR directly causing ACD. We present a case of a patient who developed an ACD secondary to application of her VVR.

  11. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Rubbing alcohol general-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS DISTRIBUTION AND USE OF DENATURED ALCOHOL AND RUM...

  12. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Rubbing alcohol general-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS DISTRIBUTION AND USE OF DENATURED ALCOHOL AND RUM...

  13. Evaluation of the national Cleanyourhands campaign to reduce Staphylococcus aureus bacteraemia and Clostridium difficile infection in hospitals in England and Wales by improved hand hygiene: four year, prospective, ecological, interrupted time series study

    PubMed Central

    Fuller, Christopher; Savage, Joan; Cookson, Barry; Hayward, Andrew; Cooper, Ben; Duckworth, Georgia; Michie, Susan; Murray, Miranda; Jeanes, Annette; Roberts, J; Teare, Louise; Charlett, Andre

    2012-01-01

    Objective To evaluate the impact of the Cleanyourhands campaign on rates of hospital procurement of alcohol hand rub and soap, report trends in selected healthcare associated infections, and investigate the association between infections and procurement. Design Prospective, ecological, interrupted time series study from 1 July 2004 to 30 June 2008. Setting 187 acute trusts in England and Wales. Intervention Installation of bedside alcohol hand rub, materials promoting hand hygiene and institutional engagement, regular hand hygiene audits, rolled out nationally from 1 December 2004. Main outcome measures Quarterly (that is, every three months) rates for each trust of hospital procurement of alcohol hand rub and liquid soap; Staphylococcus aureus bacteraemia (meticillin resistant (MRSA) and meticillin sensitive (MSSA)) and Clostridium difficile infection for each trust. Associations between procurement and infection rates assessed by mixed effect Poisson regression model (which also accounted for effect of bed occupancy, hospital type, and timing of other national interventions targeting these infections). Results Combined procurement of soap and alcohol hand rub tripled from 21.8 to 59.8 mL per patient bed day; procurement rose in association with each phase of the campaign. Rates fell for MRSA bacteraemia (1.88 to 0.91 cases per 10 000 bed days) and C difficile infection (16.75 to 9.49 cases). MSSA bacteraemia rates did not fall. Increased procurement of soap was independently associated with reduced C difficile infection throughout the study (adjusted incidence rate ratio for 1 mL increase per patient bed day 0.993, 95% confidence interval 0.990 to 0.996; P<0.0001). Increased procurement of alcohol hand rub was independently associated with reduced MRSA bacteraemia, but only in the last four quarters of the study (0.990, 0.985 to 0.995; P<0.0001). Publication of the Health Act 2006 was strongly associated with reduced MRSA bacteraemia (0.86, 0.75 to 0.98; P=0

  14. Evaluation of the national Cleanyourhands campaign to reduce Staphylococcus aureus bacteraemia and Clostridium difficile infection in hospitals in England and Wales by improved hand hygiene: four year, prospective, ecological, interrupted time series study.

    PubMed

    Stone, Sheldon Paul; Fuller, Christopher; Savage, Joan; Cookson, Barry; Hayward, Andrew; Cooper, Ben; Duckworth, Georgia; Michie, Susan; Murray, Miranda; Jeanes, Annette; Roberts, J; Teare, Louise; Charlett, Andre

    2012-05-03

    To evaluate the impact of the Cleanyourhands campaign on rates of hospital procurement of alcohol hand rub and soap, report trends in selected healthcare associated infections, and investigate the association between infections and procurement. Prospective, ecological, interrupted time series study from 1 July 2004 to 30 June 2008. 187 acute trusts in England and Wales. Installation of bedside alcohol hand rub, materials promoting hand hygiene and institutional engagement, regular hand hygiene audits, rolled out nationally from 1 December 2004. Quarterly (that is, every three months) rates for each trust of hospital procurement of alcohol hand rub and liquid soap; Staphylococcus aureus bacteraemia (meticillin resistant (MRSA) and meticillin sensitive (MSSA)) and Clostridium difficile infection for each trust. Associations between procurement and infection rates assessed by mixed effect Poisson regression model (which also accounted for effect of bed occupancy, hospital type, and timing of other national interventions targeting these infections). Combined procurement of soap and alcohol hand rub tripled from 21.8 to 59.8 mL per patient bed day; procurement rose in association with each phase of the campaign. Rates fell for MRSA bacteraemia (1.88 to 0.91 cases per 10,000 bed days) and C difficile infection (16.75 to 9.49 cases). MSSA bacteraemia rates did not fall. Increased procurement of soap was independently associated with reduced C difficile infection throughout the study (adjusted incidence rate ratio for 1 mL increase per patient bed day 0.993, 95% confidence interval 0.990 to 0.996; P < 0.0001). Increased procurement of alcohol hand rub was independently associated with reduced MRSA bacteraemia, but only in the last four quarters of the study (0.990, 0.985 to 0.995; P < 0.0001). Publication of the Health Act 2006 was strongly associated with reduced MRSA bacteraemia (0.86, 0.75 to 0.98; P = 0.02) and C difficile infection (0.75, 0.67 to 0.84; P < 0

  15. Turbine Engine Stability/Instability With Rub Forces Axisymmetric Rotor-Support Stiffness

    NASA Technical Reports Server (NTRS)

    Gallardo, Vicente; Lawrence, Charles

    2004-01-01

    The stability/instability condition of a turbine rotor with axisymmetric supports is determined in the presence of gyroscopic loads and rub-induced destabilizing forces. A modal representation of the turbine engine is used, with one mode in each of the vertical and horizontal planes. The use of non-spinning rotor modes permits an explicit treatment of gyroscopic effects. The two linearized modal equations of motion of a rotor with axisymmetric supports are reduced to a single equation in a complex variable. The resulting eigenvalues yield explicit expressions at the stability boundary, for the whirl frequency as well as the required damping for stability in the presence of the available rub-induced destabilization. Conversely, the allowable destabilization in the presence of the available damping is also given.

  16. 17. Jet Lowe, Photographer, June 1978. FIVEROLL RUB DELIVERY ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. Jet Lowe, Photographer, June 1978. FIVE-ROLL RUB DELIVERY ON A. JENKS & SON FINISHER CARD; THE DELIVERY IS CONSISTENT WITH MANUFACTURE C. 1845-1855; FROM RIGHT FRONT OF OSCILLATING MECHANISM. - Watkins Mill, County Highway MM, Lawson, Ray County, MO

  17. Head rubbing and licking reinforce social bonds in a group of captive African lions, Panthera leo.

    PubMed

    Matoba, Tomoyuki; Kutsukake, Nobuyuki; Hasegawa, Toshikazu

    2013-01-01

    Many social animals have a species-specific repertoire of affiliative behaviours that characterise individualised relationships within a group. To date, however, quantitative studies on intragroup affiliative behaviours in social carnivores have been limited. Here, we investigated the social functions of the two most commonly observed affiliative behaviours in captive African lions (Panthera leo): head rubbing and licking. We conducted behavioural observations on a captive group of lions composed of 7 males and 14 females, and tested hypotheses regarding three social functions: tension reduction, social bonding, and social status expression. Disproportionately frequent male-male and female-to-male head rubbing was observed, while more than 95% of all licking interactions occurred in female-female dyads. In accordance with the social bond hypothesis, and in disagreement with the social status expression hypothesis, both head rubbing and licking interactions were reciprocal. After controlling for spatial association, the dyadic frequency of head rubbing was negatively correlated with age difference while licking was positively correlated with relatedness. Group reunion after daily separation did not affect the frequencies of the affiliative behaviours, which was in disagreement with the predictions from the tension reduction hypothesis. These results support the social bond hypothesis for the functions of head rubbing and licking. Different patterns of affiliative behaviour between the sexes may reflect differences in the relationship quality in each sex or the differential predisposition to licking due to its original function in offspring care.

  18. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (2) made in accordance with one of the two formulas prescribed in paragraph (b) of this section, and...-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Formulas and Statements of Process General-Use Formulas § 20.118 Rubbing alcohol general-use formula. (a...

  19. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (2) made in accordance with one of the two formulas prescribed in paragraph (b) of this section, and...-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Formulas and Statements of Process General-Use Formulas § 20.118 Rubbing alcohol general-use formula. (a...

  20. 27 CFR 20.118 - Rubbing alcohol general-use formula.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (2) made in accordance with one of the two formulas prescribed in paragraph (b) of this section, and...-use formula. 20.118 Section 20.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Formulas and Statements of Process General-Use Formulas § 20.118 Rubbing alcohol general-use formula. (a...

  1. Laparoscopic cholecystectomy poses physical injury risk to surgeons: analysis of hand technique and standing position.

    PubMed

    Youssef, Yassar; Lee, Gyusung; Godinez, Carlos; Sutton, Erica; Klein, Rosemary V; George, Ivan M; Seagull, F Jacob; Park, Adrian

    2011-07-01

    This study compares surgical techniques and surgeon's standing position during laparoscopic cholecystectomy (LC), investigating each with respect to surgeons' learning, performance, and ergonomics. Little homogeneity exists in LC performance and training. Variations in standing position (side-standing technique vs. between-standing technique) and hand technique (one-handed vs. two-handed) exist. Thirty-two LC procedures performed on a virtual reality simulator were video-recorded and analyzed. Each subject performed four different procedures: one-handed/side-standing, one-handed/between-standing, two-handed/side-standing, and two-handed/between-standing. Physical ergonomics were evaluated using Rapid Upper Limb Assessment (RULA). Mental workload assessment was acquired with the National Aeronautics and Space Administration-Task Load Index (NASA-TLX). Virtual reality (VR) simulator-generated performance evaluation and a subjective survey were analyzed. RULA scores were consistently lower (indicating better ergonomics) for the between-standing technique and higher (indicating worse ergonomics) for the side-standing technique, regardless of whether one- or two-handed. Anatomical scores overall showed side-standing to have a detrimental effect on the upper arms and trunk. The NASA-TLX showed significant association between the side-standing position and high physical demand, effort, and frustration (p<0.05). The two-handed technique in the side-standing position required more effort than the one-handed (p<0.05). No difference in operative time or complication rate was demonstrated among the four procedures. The two-handed/between-standing method was chosen as the best procedure to teach and standardize. Laparoscopic cholecystectomy poses a risk of physical injury to the surgeon. As LC is currently commonly performed in the United States, the left side-standing position may lead to increased physical demand and effort, resulting in ergonomically unsound conditions for

  2. Structural geology of the Rub' Al-Khali Basin, Saudi Arabia

    NASA Astrophysics Data System (ADS)

    Stewart, S. A.

    2016-10-01

    The Rub' Al-Khali basin lies below a Quaternary sand sea, and the structural evolution from the Late Precambrian to Neogene is known only from reflection seismic, gravity, and magnetic data, and wells. Gravity and magnetic data show north-south and northwest-southeast trends, matching mapped Precambrian faults. The deepest structures imaged on reflection seismic data are undrilled Precambrian rifts filled with layered strata at depths up to 13 km. The distribution of Ediacaran-Cambrian Ara/Hormuz mobile salt is restricted to an embayment in the eastern Rub' Al-Khali. The Precambrian rifts show local inversion and were peneplained at base Phanerozoic. A broad crustal-scale fold (Qatar Arch) developed in the Carboniferous and amplified in the Late Triassic, separating subbasins in the west and east Rub' Al-Khali. A phase of kilometer-scale folding occurred in the Late Cretaceous, coeval with thrusting and ophiolite obduction in eastern Oman. These folds trend predominantly north-south, oblique to the northwesterly shortening direction, and occasionally have steep fault zones close to their axial surfaces. The trend and location of these folds closely matches the Precambrian lineaments identified in this study, demonstrating preferential reactivation of basement structures. Compression along the Zagros suture reactivated these folds in the Neogene, this time the result of highly oblique, north-northeast to south-southwest shortening. Cretaceous-Tertiary fold style is interpreted as transpression with minor strain partitioning. Permian, Jurassic, and Eocene evaporite horizons played no role in the structural evolution of the basin, but the Eocene evaporites caused widespread kilometer-scale dissolution collapse structures in the basin center.

  3. The hammer QSD-quick stop device for high speed machining and rubbing

    NASA Technical Reports Server (NTRS)

    Black, J. T.; James, C. R.

    1980-01-01

    A quick stop device (QSD) was designed for use in orthogonal machining and rubbing experiments. QSD's are used to obtain chip root samples that are representative of the deformation taking place during dynamic (actual) cutting conditions. These 'frozen' specimens are helpful in examining the plastic deformation that occurs in the regions of compression and shear which form the chip; the secondary shear at the tool-chip interface; and the nose ploughing/flank rubbing action which operates on the newly machined surface. The Hammer QSD employs a shear pin mechanism, broken by a flying hammer, which is traveling at the same velocity as the workpiece. The device has been successfully tested up to 6000 sfpm (30.48 m/sec).

  4. Pediatric mandibular fractures: a free hand technique.

    PubMed

    Davison, S P; Clifton, M S; Davison, M N; Hedrick, M; Sotereanos, G

    2001-01-01

    The treatment of pediatric mandibular fractures is rare, controversial, and complicated by mixed dentition. To determine if open mandibular fracture repair with intraoral and extraoral rigid plate placement, after free hand occlusal and bone reduction, without intermaxillary fixation (IMF), is appropriate and to discuss postoperative advantages, namely, maximal early return of function and minimal oral hygiene issues. A group of 29 pediatric patients with a mandibular fracture were examined. Twenty pediatric patients (13 males and 7 females) with a mean age of 9 years (age range, 1-17 years) were treated using IMF. All patients were treated by the same surgeon (G.S.). Surgical time for plating was reduced by 1 hour, the average time to place patients in IMF. The patients who underwent open reduction internal fixation without IMF ate a soft mechanical diet by postoperative day 3 compared with postoperative day 16 for those who underwent IMF. Complication rates related to fixation technique were comparable at 20% for those who did not undergo IMF and 33% for those who did. We believe that free hand reduction is a valuable technique to reduce operative time for pediatric mandibular fractures. It maximizes return to function while minimizing the oral hygiene issues and hardware removal of intermaxillary function.

  5. Adherence to hand hygiene protocol by clinicians and medical students at Queen Elizabeth Central Hospital, Blantyre-Malawi.

    PubMed

    Kalata, N L; Kamange, L; Muula, A S

    2013-06-01

    While communicable diseases are the leading causes of morbidity and mortality in Malawi, the contribution of nosocomial or hospital-acquired infections (HAIs) is unknown but could be substantial. The single most important method of preventing nosocomial infections is hand hygiene. We report a study which was conducted in 2011 to investigate adherence to hand hygiene protocols by clinicians and medical students working at Queen Elizabeth Central Hospital in Blantyre, Malawi. There were two parts to the study: a single blinded arm in which participants were observed without their knowledge by trained nurses; and a second arm which included self-completion of questionnaire after participant consent was obtained. The 2009 World Health Organization hand hygiene technique and recommendations which were adopted by Queen Elizabeth Central Hospital were used to define an opportunity for hand washing and effectiveness of hand washing. Hand hygiene effectiveness was defined as adherence to at least 6 out of 7 steps (80%) of the hand hygiene technique when using alcohol-based formulation or at least 8 out of 10 steps (80%) of the hand hygiene technique when using water and soap formulation before and after having direct contact with patients or their immediate surroundings. Clinicians were found to have disinfected their hands more than medical students (p<0.05) but effectiveness was similar and very low between the two groups (p=0.2). No association was also found between having a personal hand sanitizer and hand hygiene practice (p=0.3). Adherence to hand hygiene was found to be 23%. Most of the participants mentioned infection transmission prevention as a reason for disinfecting their hands. Other reasons mentioned included: a routine personal hand hygiene behaviour and discomfort if not washing hands. The top three reasons why they did not disinfect hands were forgetfulness, unavailability of sanitizers and negligence. Adherence to hand hygiene practice was found to be low

  6. A Soft Casting Technique for Managing Pediatric Hand and Foot Burns.

    PubMed

    Choi, Young Mee; Nederveld, Cindy; Campbell, Kristen; Moulton, Steven

    2018-04-04

    Hand and foot burns in children are difficult to dress. The authors have developed a soft casting technique to manage burns to these areas. The aim of this study is to report the outcomes using weekly dressing changes with a soft casting technique to manage pediatric hand and foot burns in the outpatient setting. A retrospective chart review was performed on children with burns to the hands or feet, who underwent dressing changes with a soft casting technique at the Children's Hospital Colorado Burn Center. Soft casting was performed by placing antibiotic ointment-impregnated nonadherent gauze over the burn wound(s), wrapping the extremity using rolled gauze, applying soft cast pad, plaster, soft cast tape, and an elastic bandage. This was changed weekly. Two hundred ninety-eight children with hand burns had a mean age of 16.8 ± 2 months. Two hundred forty-eight children had partial thickness burn injuries (83%), 50 had full thickness burn injuries (17%), and the mean total body surface area (TBSA) was 1 ± 2.4%. The mean time to heal was 10.1 ± 1.7 days for all subjects. Sixty-six children with foot burns were identified with a mean age of 24 ± 2.6 months. Forty-six children had partial thickness injuries (70%), 20 had full thickness burn injuries (30%), and the mean TBSA was 2.3 ± 2.9%. The mean time to heal was 14.1 ± 2.2 days for all subjects. Weekly dressing changes using a soft casting technique are effective for the outpatient management of pediatric hand and foot burns. This method avoids costly inpatient hospital care, reduces the number of painful dressing changes, and allows children to heal in their own environment.

  7. Antimicrobial efficacy of alcohol-based hand gels.

    PubMed

    Guilhermetti, M; Marques Wiirzler, L A; Castanheira Facio, B; da Silva Furlan, M; Campo Meschial, W; Bronharo Tognim, M C; Botelho Garcia, L; Luiz Cardoso, C

    2010-03-01

    In recent years, several commercial alcohol-based hand gels have appeared on the market to improve the hand-cleansing compliance of healthcare workers. Although the antimicrobial efficacy of these products has been reported in different countries, few studies have investigated this subject in Brazil. In this study, we assessed the antimicrobial efficacy of 12 alcohol-based hand gels produced in Brazil, containing 70% w/w or v/v ethyl alcohol as the active ingredient, according to the European Standard EN 1500 (EN 1500). The following alcohol gels were tested: Hand Gel, Voga Gel, Solumax Solugel, Doctor Clean, Rio Gel, Clear Gel, Sevengel, Hand CHC, Gel Bac, WBL-50 Gel, Sanigel and Soft Care Gel. In addition, 70% w/w ethyl alcohol and three alcohol-based hand rubs (Sterillium, Sterillium Gel, and Spitaderm), commonly used in Europe and effective according to EN 1500, were also tested. All the products tested, except for two, were approved by the EN 1500 test protocol with a 60s application. The results confirmed the antimicrobial efficacy of the majority of the alcohol gels produced in Brazil for hand hygiene of healthcare workers. Copyright 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  8. Video observation of hand hygiene practices during routine companion animal appointments and the effect of a poster intervention on hand hygiene compliance

    PubMed Central

    2014-01-01

    Background Hand hygiene is considered one of the most important infection control measures in human healthcare settings, but there is little information available regarding hand hygiene frequency and technique used in veterinary clinics. The objectives of this study were to describe hand hygiene practices associated with routine appointments in companion animal clinics in Ontario, and the effectiveness of a poster campaign to improve hand hygiene compliance. Results Observation of hand hygiene practices was performed in 51 clinics for approximately 3 weeks each using 2 small wireless surveillance cameras: one in an exam room, and one in the most likely location for hand hygiene to be performed outside the exam room following an appointment. Data from 38 clinics were included in the final analysis, including 449 individuals, 1139 appointments before and after the poster intervention, and 10894 hand hygiene opportunities. Overall hand hygiene compliance was 14% (1473/10894), while before and after patient contact compliance was 3% (123/4377) and 26% (1145/4377), respectively. Soap and water was used for 87% (1182/1353) of observed hand hygiene attempts with a mean contact time of 4 s (median 2 s, range 1-49 s), while alcohol-based hand rub (ABHR) was used for 7% (98/1353) of attempts with a mean contact time of 8 s (median 7 s, range 1-30 s). The presence of the posters had no significant effect on compliance, although some staff reported that they felt the posters did increase their personal awareness of the need to perform hand hygiene, and the posters had some effect on product contact times. Conclusions Overall hand hygiene compliance in veterinary clinics in this study was low, and contact time with hand hygiene products was frequently below current recommendations. Use of ABHR was low despite its advantages over hand washing and availability in the majority of clinics. The poster campaign had a limited effect on its own, but could still be used as a

  9. Video observation of hand hygiene practices during routine companion animal appointments and the effect of a poster intervention on hand hygiene compliance.

    PubMed

    Anderson, Maureen E C; Sargeant, Jan M; Weese, J Scott

    2014-05-07

    Hand hygiene is considered one of the most important infection control measures in human healthcare settings, but there is little information available regarding hand hygiene frequency and technique used in veterinary clinics. The objectives of this study were to describe hand hygiene practices associated with routine appointments in companion animal clinics in Ontario, and the effectiveness of a poster campaign to improve hand hygiene compliance. Observation of hand hygiene practices was performed in 51 clinics for approximately 3 weeks each using 2 small wireless surveillance cameras: one in an exam room, and one in the most likely location for hand hygiene to be performed outside the exam room following an appointment. Data from 38 clinics were included in the final analysis, including 449 individuals, 1139 appointments before and after the poster intervention, and 10894 hand hygiene opportunities. Overall hand hygiene compliance was 14% (1473/10894), while before and after patient contact compliance was 3% (123/4377) and 26% (1145/4377), respectively. Soap and water was used for 87% (1182/1353) of observed hand hygiene attempts with a mean contact time of 4 s (median 2 s, range 1-49 s), while alcohol-based hand rub (ABHR) was used for 7% (98/1353) of attempts with a mean contact time of 8 s (median 7 s, range 1-30 s). The presence of the posters had no significant effect on compliance, although some staff reported that they felt the posters did increase their personal awareness of the need to perform hand hygiene, and the posters had some effect on product contact times. Overall hand hygiene compliance in veterinary clinics in this study was low, and contact time with hand hygiene products was frequently below current recommendations. Use of ABHR was low despite its advantages over hand washing and availability in the majority of clinics. The poster campaign had a limited effect on its own, but could still be used as a component of a multimodal hand

  10. Analytical and experimental investigation of rubbing interaction in labyrinth seals for a liquid hydrogen fuel pump. [space shuttle main engine

    NASA Technical Reports Server (NTRS)

    Dolan, F. X.; Kennedy, F. E.; Schulson, E. M.

    1984-01-01

    Cracking of the titanium knife edges on the labyrinth seals of the liquid hydrogen fuel pump in the Space Shuttle main engine is considered. Finite element analysis of the thermal response of the knife edge in sliding contact with the wear ring surface shows that interfacial temperatures can be quite high and they are significantly influenced by the thermal conductivity of the surfaces in rubbing contact. Thermal shock experiments on a test specimen similar to the knife edge geometry demonstrate that cracking of the titanium alloy is possible in a situation involving repeated thermal cycles over a wide temperature range, as might be realized during a rub in the liquid hydrogen fuel pump. High-speed rub interaction tests were conducted using a representative knife edge and seal geometry over a broad range of interaction rates and alternate materials were experimentally evaluated. Plasma-sprayed aluminum-graphite was found to be significantly better than presently used aluminum alloy seals from the standpoint of rub performance. Ion nitriding the titanium alloy knife-edges also improved rub performance compared to the untreated baseline.

  11. Comparison of the antibacterial efficacy and acceptability of an alcohol-based hand rinse with two alcohol-based hand gels during routine patient care.

    PubMed

    Barbut, Frédéric; Maury, Eric; Goldwirt, Laurianne; Boëlle, Piérre-Yves; Neyme, Denis; Aman, Rubina; Rossi, Beatrice; Offenstadt, Georges

    2007-06-01

    The aims of this study were to compare the antibacterial efficacy of handrubbing with an alcoholic rinse (AHRR) and two different alcoholic gels (AHRG) in reducing hand contamination under practical use conditions. We wanted to assess the acceptability of the three products and to determine the effect of each product on overall hand hygiene compliance. A prospective alternating time-series clinical trial was performed in a medical intensive care unit. The study was divided into three six-week periods (P1, P2, P3). Handrubbing was achieved with Sterillium rinse (AHRR) during P1, sterillium gel(AHRG-1) during P2 and Manugel Plus (AHRG-2) during P3. Pre- and post-rubbing hand contaminations were assessed immediately after a direct contact with a patient, using the glove juice technique. Health care workers (HCWs) evaluated the acceptability of the products through a self-administered anonymous questionnaire. Compliance of HCWs with hand hygiene was assessed during the three periods. We studied 242 handrubbing opportunities. The mean reduction factor (expressed as the Log(10) CFU/mL) of the AHRR, AHRG-1 and AHRG-2 were 1.28+/-0.95, 1.29+/-0.84 and 0.51+/-0.73, respectively (p<0.001). Assessment of the three products by HCWs indicated that AHRR and AHRG-1 were significantly better accepted than AHRG-2. The overall compliance of HCWs to hand hygiene was better when gel was available. Under practical use conditions, AHRG-1 and AHRR were more effective than AHRG-2, although all were claimed to pass the European standard EN1500. In vivo trials are essential to compare the antimicrobial efficacy of products for handrubbing.

  12. A finite element-based algorithm for rubbing induced vibration prediction in rotors

    NASA Astrophysics Data System (ADS)

    Behzad, Mehdi; Alvandi, Mehdi; Mba, David; Jamali, Jalil

    2013-10-01

    In this paper, an algorithm is developed for more realistic investigation of rotor-to-stator rubbing vibration, based on finite element theory with unilateral contact and friction conditions. To model the rotor, cross sections are assumed to be radially rigid. A finite element discretization based on traditional beam theories which sufficiently accounts for axial and transversal flexibility of the rotor is used. A general finite element discretization model considering inertial and viscoelastic characteristics of the stator is used for modeling the stator. Therefore, for contact analysis, only the boundary of the stator is discretized. The contact problem is defined as the contact between the circular rigid cross section of the rotor and “nodes” of the stator only. Next, Gap function and contact conditions are described for the contact problem. Two finite element models of the rotor and the stator are coupled via the Lagrange multipliers method in order to obtain the constrained equation of motion. A case study of the partial rubbing is simulated using the algorithm. The synchronous and subsynchronous responses of the partial rubbing are obtained for different rotational speeds. In addition, a sensitivity analysis is carried out with respect to the initial clearance, the stator stiffness, the damping parameter, and the coefficient of friction. There is a good agreement between the result of this research and the experimental result in the literature.

  13. Chromosome-Encoded Broad-Spectrum Ambler Class A β-Lactamase RUB-1 from Serratia rubidaea

    PubMed Central

    Didi, Jennifer; Ergani, Ayla; Lima, Sandra

    2016-01-01

    ABSTRACT Whole-genome sequencing of Serratia rubidaea CIP 103234T revealed a chromosomally located Ambler class A β-lactamase gene. The gene was cloned, and the β-lactamase, RUB-1, was characterized. RUB-1 displayed 74% and 73% amino acid sequence identity with the GIL-1 and TEM-1 penicillinases, respectively, and its substrate profile was similar to that of the latter β-lactamases. Analysis by 5′ rapid amplification of cDNA ends revealed promoter sequences highly divergent from the Escherichia coli σ70 consensus sequence. This work further illustrates the heterogeneity of β-lactamases among Serratia spp. PMID:27956418

  14. Three-Hand Endoscopic Endonasal Transsphenoidal Surgery: Experience With an Anatomy-Preserving Mononostril Approach Technique.

    PubMed

    Eseonu, Chikezie I; ReFaey, Karim; Pamias-Portalatin, Eva; Asensio, Javier; Garcia, Oscar; Boahene, Kofi D; Quiñones-Hinojosa, Alfredo

    2018-02-01

    Variations on the endoscopic transsphenoidal approach present unique surgical techniques that have unique effects on surgical outcomes, extent of resection (EOR), and anatomical complications. To analyze the learning curve and perioperative outcomes of the 3-hand endoscopic endonasal mononostril transsphenoidal technique. Prospective case series and retrospective data analysis of patients who were treated with the 3-hand transsphenoidal technique between January 2007 and May 2015 by a single neurosurgeon. Patient characteristics, preoperative presentation, tumor characteristics, operative times, learning curve, and postoperative outcomes were analyzed. Volumetric EOR was evaluated, and a logistic regression analysis was used to assess predictors of EOR. Two hundred seventy-five patients underwent an endoscopic transsphenoidal surgery using the 3-hand technique. One hundred eighteen patients in the early group had surgery between 2007 and 2010, while 157 patients in the late group had surgery between 2011 and 2015. Operative time was significantly shorter in the late group (161.6 min) compared to the early group (211.3 min, P = .001). Both cohorts had similar EOR (early group 84.6% vs late group 85.5%, P = .846) and postoperative outcomes. The learning curve showed that it took 54 cases to achieve operative proficiency with the 3-handed technique. Multivariate modeling suggested that prior resections and preoperative tumor size are important predictors for EOR. We describe a 3-hand, mononostril endoscopic transsphenoidal technique performed by a single neurosurgeon that has minimal anatomic distortion and postoperative complications. During the learning curve of this technique, operative time can significantly decrease, while EOR, postoperative outcomes, and complications are not jeopardized. Copyright © 2017 by the Congress of Neurological Surgeons

  15. Chromosome-Encoded Broad-Spectrum Ambler Class A β-Lactamase RUB-1 from Serratia rubidaea.

    PubMed

    Bonnin, Rémy A; Didi, Jennifer; Ergani, Ayla; Lima, Sandra; Naas, Thierry

    2017-02-01

    Whole-genome sequencing of Serratia rubidaea CIP 103234 T revealed a chromosomally located Ambler class A β-lactamase gene. The gene was cloned, and the β-lactamase, RUB-1, was characterized. RUB-1 displayed 74% and 73% amino acid sequence identity with the GIL-1 and TEM-1 penicillinases, respectively, and its substrate profile was similar to that of the latter β-lactamases. Analysis by 5' rapid amplification of cDNA ends revealed promoter sequences highly divergent from the Escherichia coli σ 70 consensus sequence. This work further illustrates the heterogeneity of β-lactamases among Serratia spp. Copyright © 2017 American Society for Microbiology.

  16. Efficacy of the World Health Organization-recommended handwashing technique and a modified washing technique to remove Clostridium difficile from hands.

    PubMed

    Deschênes, Philippe; Chano, Frédéric; Dionne, Léa-Laurence; Pittet, Didier; Longtin, Yves

    2017-08-01

    The efficacy of the World Health Organization (WHO)-recommended handwashing technique against Clostridium difficile is uncertain, and whether it could be improved remains unknown. Also, the benefit of using a structured technique instead of an unstructured technique remains unclear. This study was a prospective comparison of 3 techniques (unstructured, WHO, and a novel technique dubbed WHO shortened repeated [WHO-SR] technique) to remove C difficile. Ten participants were enrolled and performed each technique. Hands were contaminated with 3 × 10 6 colony forming units (CFU) of a nontoxigenic strain containing 90% spores. Efficacy was assessed using the whole-hand method. The relative efficacy of each technique and of a structured (either WHO or WHO-SR) vs an unstructured technique were assessed by Mann-Whitney U test and Wilcoxon signed-rank test. The median effectiveness of the unstructured, WHO, and WHO-SR techniques in log 10 CFU reduction was 1.30 (interquartile range [IQR], 1.27-1.43), 1.71 (IQR, 1.34-1.91), and 1.70 (IQR, 1.54-2.42), respectively. The WHO-SR technique was significantly more efficacious than the unstructured technique (P = .01). Washing hands with a structured technique was more effective than washing with an unstructured technique (median, 1.70 vs 1.30 log 10 CFU reduction, respectively; P = .007). A structured washing technique is more effective than an unstructured technique against C difficile. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  17. A recessive mutation in the RUB1-conjugating enzyme, RCE1, reveals a requirement for RUB modification for control of ethylene biosynthesis and proper induction of basic chitinase and PDF1.2 in Arabidopsis.

    PubMed

    Larsen, Paul B; Cancel, Jesse D

    2004-05-01

    By screening etiolated Arabidopsis seedlings for mutants with aberrant ethylene-related phenotypes, we identified a mutant that displays features of the ethylene-mediated triple response even in the absence of ethylene. Further characterization showed that the phenotype observed for the dark-grown seedlings of this mutant is reversible by prevention of ethylene perception and is dependent on a modest increase in ethylene production correlated with an increase in 1-aminocyclopropane-1-carboxylic acid (ACC) oxidase (ACO) activity in the hypocotyl. Molecular characterization of leaves of the mutant revealed severely impaired induction of basic chitinase (chiB) and plant defensin (PDF)1.2 following treatment with jasmonic acid and/or ethylene. Positional cloning of the mutation resulted in identification of a 49-bp deletion in RCE1 (related to ubiquitin 1 (RUB1)-conjugating enzyme), which has been demonstrated to be responsible for covalent attachment of RUB1 to the SCF (Skpl Cdc 53 F-box) ubiquitin ligase complex to modify its activity. Our analyses with rce1-2 demonstrate a previously unknown requirement for RUB1 modification for regulation of ethylene biosynthesis and proper induction of defense-related genes in Arabidopsis.

  18. Rescuing the Clinical Breast Examination: Advances in Classifying Technique and Assessing Physician Competency.

    PubMed

    Laufer, Shlomi; D'Angelo, Anne-Lise D; Kwan, Calvin; Ray, Rebbeca D; Yudkowsky, Rachel; Boulet, John R; McGaghie, William C; Pugh, Carla M

    2017-12-01

    Develop new performance evaluation standards for the clinical breast examination (CBE). There are several, technical aspects of a proper CBE. Our recent work discovered a significant, linear relationship between palpation force and CBE accuracy. This article investigates the relationship between other technical aspects of the CBE and accuracy. This performance assessment study involved data collection from physicians (n = 553) attending 3 different clinical meetings between 2013 and 2014: American Society of Breast Surgeons, American Academy of Family Physicians, and American College of Obstetricians and Gynecologists. Four, previously validated, sensor-enabled breast models were used for clinical skills assessment. Models A and B had solitary, superficial, 2 cm and 1 cm soft masses, respectively. Models C and D had solitary, deep, 2 cm hard and moderately firm masses, respectively. Finger movements (search technique) from 1137 CBE video recordings were independently classified by 2 observers. Final classifications were compared with CBE accuracy. Accuracy rates were model A = 99.6%, model B = 89.7%, model C = 75%, and model D = 60%. Final classification categories for search technique included rubbing movement, vertical movement, piano fingers, and other. Interrater reliability was (k = 0.79). Rubbing movement was 4 times more likely to yield an accurate assessment (odds ratio 3.81, P < 0.001) compared with vertical movement and piano fingers. Piano fingers had the highest failure rate (36.5%). Regression analysis of search pattern, search technique, palpation force, examination time, and 6 demographic variables, revealed that search technique independently and significantly affected CBE accuracy (P < 0.001). Our results support measurement and classification of CBE techniques and provide the foundation for a new paradigm in teaching and assessing hands-on clinical skills. The newly described piano fingers palpation technique was noted to have unusually high

  19. Triple dye plus rubbing alcohol versus triple dye alone for umbilical cord care.

    PubMed

    Suliman, Alawia K; Watts, Heidi; Beiler, Jessica; King, Tonya S; Khan, Sana; Carnuccio, Marybeth; Paul, Ian M

    2010-01-01

    Current practices for umbilical cord care vary across centers, but the evidence regarding these practices and their impact on cord separation, complications, and health care use are limited. The objective of this study was to compare the effect of triple dye alone (brilliant green, crystal violet, and proflavine hemisulfate) versus triple dye plus rubbing alcohol (isopropyl alcohol) twice daily on time to umbilical cord separation, complications, and health care use. For the 90 newborns who completed the study, there were no significant differences between treatment groups for time to cord separation, cord-related morbidities, or cord-related urgent care. Based on these study results, there does not appear to be significant benefit to the addition of twice daily applications of rubbing alcohol to neonatal umbilical cords following triple dye treatment after birth.

  20. In vitro-in vivo sequence studies as a method of selecting the most efficacious alcohol-based solution for hygienic hand disinfection.

    PubMed

    Herruzo, R; Vizcaino, M J; Herruzo, I

    2010-05-01

    The use of alcohol-based hand rubs serves to reduce hospital-acquired infections. Many products of this type are now on offer and it is essential to know how to rank their efficacy. A sequence of tests is proposed here to compare any given new alcohol-based solution against the reference solution (60% 2-isopropyl-alcohol) with 30 s of contact time: (i) in vitro (with pig skin as carrier) testing of >30 species of microorganism; (ii) in vitro assessment of residual efficacy (after 30 min of drying); (iii) in vivo study of transient microbiota (modification of the EN 1500 standard procedure) using four ATCC strains; (iv) in vivo study of resident hand microbiota. After performing the in vitro evaluation of seven alcohol-based hand rubs, the two most efficacious (chlorhexidine-quac-alcohol and mecetronium- alcohol) were chosen and studied, comparatively with the reference solution (60% isopropyl alcohol), in vitro (for chemical sustainability on the skin) and in vivo (against transient and resident microbiota). Chlorhexidine-quac-alcohol proved to be significantly superior to mecetronium-alcohol or the reference solution in all tests, except against resident microbiota for which the improvement was not statistically significant.

  1. Intensified hand-hygiene campaign including soap-and-water wash may prevent acute infections in office workers, as shown by a recognized-exposure -adjusted analysis of a randomized trial.

    PubMed

    Hovi, Tapani; Ollgren, Jukka; Savolainen-Kopra, Carita

    2017-01-09

    Variable exposure to causative agents of acute respiratory (RTI) or gastrointestinal tract infections (GTI) is a significant confounding factor in the analysis of the efficacy of interventions concerning these infections. We had an exceptional opportunity to reanalyze a previously published dataset from a trial assessing the effect of enhanced hand hygiene on the occurrence of RTI or GTI in adults, after adjustment for reported exposure and other covariates. Twenty-one working units (designated clusters) each including at least 50 office employees, totaling 1,270 persons, were randomized into two intervention arms (either using water-and-soap or alcohol-rub in hand cleansing), or in the control arm. Self-reported data was collected through weekly emails and included own symptoms of RTI or GTI, and exposures to other persons with similar symptoms. Differences in the weekly occurrences of RTI and GTI symptoms between the arms were analyzed using multilevel binary regression model with log link with personal and cluster specific random effects, self-reported exposure to homologous disease, randomization triplet, and seasonality as covariates in the Bayesian framework. Over the 16 months duration of the trial, 297 persons in the soap and water arm, 238 persons in the alcohol-based hand rub arm, and 230 controls sent reports. The arms were similar in age distribution and gender ratios. A temporally-associated reported exposure strongly increased the risk of both types of infection in all trial arms. Persons in the soap-and-water arm reported a significantly - about 24% lower weekly prevalence of GTI than the controls whether they had observed an exposure or not during the preceding week, while for RTI, this intervention reduced the prevalence only during weeks without a reported exposure. Alcohol-rub did not affect the symptom prevalence. We conclude that while frequent and careful hand washing with soap and water partially protected office-working adults from GTI, the

  2. Iterative co-creation for improved hand hygiene and aseptic techniques in the operating room: experiences from the safe hands study.

    PubMed

    Erichsen Andersson, Annette; Frödin, Maria; Dellenborg, Lisen; Wallin, Lars; Hök, Jesper; Gillespie, Brigid M; Wikström, Ewa

    2018-01-04

    Hand hygiene and aseptic techniques are essential preventives in combating hospital-acquired infections. However, implementation of these strategies in the operating room remains suboptimal. There is a paucity of intervention studies providing detailed information on effective methods for change. This study aimed to evaluate the process of implementing a theory-driven knowledge translation program for improved use of hand hygiene and aseptic techniques in the operating room. The study was set in an operating department of a university hospital. The intervention was underpinned by theories on organizational learning, culture and person centeredness. Qualitative process data were collected via participant observations and analyzed using a thematic approach. Doubts that hand-hygiene practices are effective in preventing hospital acquired infections, strong boundaries and distrust between professional groups and a lack of psychological safety were identified as barriers towards change. Facilitated interprofessional dialogue and learning in "safe spaces" worked as mechanisms for motivation and engagement. Allowing for the free expression of different opinions, doubts and viewing resistance as a natural part of any change was effective in engaging all professional categories in co-creation of clinical relevant solutions to improve hand hygiene. Enabling nurses and physicians to think and talk differently about hospital acquired infections and hand hygiene requires a shift from the concept of one-way directed compliance towards change and learning as the result of a participatory and meaning-making process. The present study is a part of the Safe Hands project, and is registered with ClinicalTrials.gov (ID: NCT02983136 ). Date of registration 2016/11/28, retrospectively registered.

  3. Why language matters: a tour through hand hygiene literature.

    PubMed

    Pires, Daniela; Tartari, Ermira; Bellissimo-Rodrigues, Fernando; Pittet, Didier

    2017-01-01

    Hand hygiene has evolved over the last decades and many terminologies emerged. We aimed to analyse the evolution in the frequency of utilization of key hand hygiene terms in the literature along the years. We identified keywords and Medical Subject Headings (MeSH) used in MEDLINE® indexation related to hand hygiene by searching international guidelines and the MeSH database. We performed a MEDLINE® search combining the selected keywords and MeSH and analysed the number of publications retrieved yearly. The literature search yielded 9019 publications when all hand hygiene related search terms were combined, between 1921 and November 2016. The total number of publications per year increased from a median of 4 (IQR 3, 6) in the 1950's to 554 (IQR 478, 583) between 2011 and 2015. The most frequently used keywords are hand disinfection, hand hygiene, hand washing, handrub, hand sanitizer and alcohol-based hand rub (ABHR). Until the 1990s, hand disinfection and hand washing were the most frequently used terms. Whilst the last decade has seen a remarkable increase in publications mentioning hand disinfection and hand hygiene and for the first time handrub, hand sanitizers and ABHR were introduced in the literature. Hand disinfection, hand hygiene and hand sanitizers are the main MeSH used by MEDLINE®. Since 2013 hand hygiene is the most frequently used MeSH and keyword. The change seen in literature in the last two decades, from hand washing and hand disinfection to hand hygiene, most probably reflect the paradigm shift favouring use of ABHR over soap and water promoted by international guidelines in the early 2000s.

  4. Healthcare professionals' hand hygiene knowledge and beliefs in the United Arab Emirates.

    PubMed

    Ng, Wai Khuan; Shaban, Ramon Z; van de Mortel, Thea

    2017-05-01

    Hand hygiene at key moments during patient care is considered an important infection prevention and control measure to reduce healthcare-associated infections. While there is extensive research in Western settings, there is little in the United Arab Emirates where particular cultural and religious customs are thought to influence hand hygiene behaviour. To examine the hand hygiene knowledge and beliefs of health professionals at a tertiary care hospital in the United Arab Emirates. A mixed methods design employed a survey followed by focus groups with nurses and doctors. A total of 109 participants (13.6%) completed the survey: 96 nurses (88%) and 13 doctors (12%). Doctors' hand hygiene knowledge was slightly higher than that of nurses (78.5% versus 73.5%). There was no significant difference in scores on the hand hygiene beliefs scale between nurses (M = 103.06; SD = 8.0) and doctors (M = 99.00; SD = 10.53; t (80) = 1.55; p = 0.13, two-tailed). Seven categories emerged following transcript analysis. Hand hygiene knowledge scores suggest further hand hygiene education is required, especially on alcohol-based hand rub use. Addressing doctors' beliefs is particularly important given the leadership roles that doctors play in healthcare settings.

  5. Apical extrusion of debris using two hand and two rotary instrumentation techniques.

    PubMed

    Reddy, S A; Hicks, M L

    1998-03-01

    The purpose of this study was to investigate the quantity of apical debris produced in vitro using two hand and two rotary instrumentation techniques. Sixty minimally curved, mature human mandibular premolars with single canals were divided into 4 groups of 15 teeth each and prepared using step-back instrumentation with K-files, balanced force with Flex-R files, Lightspeed nickel-titanium instruments, or .04 taper ProFile Series 29 rotary nickel-titanium files. Debris extruded through the apical foramen during instrumentation was collected on preweighed filters. The mean weight of extruded debris for each group was statistically analyzed using a Kruskal Wallis one-way analysis of variance and a Mann-Whitney U rank sum tested. Although all instrumentation techniques produced apically extruded debris, step-back instrumentation produced significantly more debris than the other methods (p < 0.0001). There was no difference between balanced force hand instrumentation and the two rotary nickel-titanium instrumentation methods (p > 0.05). Hand or engine-driven instrumentation that uses rotation seems to reduce significantly the amount of debris extruded apically when compared with a push-pull (filing) technique. Decreased apical extrusion of debris has strong implications for a decreased incidence of postoperative inflammation and pain.

  6. Four multifaceted countrywide campaigns to promote hand hygiene in Belgian hospitals between 2005 and 2011: impact on compliance to hand hygiene.

    PubMed

    Costers, M; Viseur, N; Catry, B; Simon, A

    2012-05-03

    Four consecutive one-month campaigns were organised to promote hand hygiene in Belgian hospitals between 2005 and 2011. The campaigns included a combination of reminders in wards, educational sessions for healthcare workers, promotion of alcohol-based hand rub use, increasing patient awareness, and audits with performance feedback. Prior and after each one month intervention period, the infection control teams measured hand hygiene compliance of healthcare workers by direct observation using a standardised observation roster. A total of 738,367 opportunities for hand hygiene were observed over the four campaigns. Compliance with hand hygiene significantly increased from 49.6% before to 68.6% after the intervention period for the first, from 53.2% to 69.5% for the second, from 58.0% to 69.1% for the third, and from 62.3% to 72.9% for the fourth campaign. The highest compliance rates were consistently observed in paediatric units. Compliance rates were always markedly lower among physicians than nurses. After patient contact and body fluid exposure risk, compliance rates were noticeably higher than before patient contact and performing aseptic procedures. We conclude that repeated countrywide campaigns to promote hand hygiene result in positive long-term outcomes. However, lower compliance rates among physicians compared with nurses, before patient contact, and before performing aseptic procedures remain challenges for future campaigns.

  7. A general electromagnetic excitation model for electrical machines considering the magnetic saturation and rub impact

    NASA Astrophysics Data System (ADS)

    Xu, Xueping; Han, Qinkai; Chu, Fulei

    2018-03-01

    The electromagnetic vibration of electrical machines with an eccentric rotor has been extensively investigated. However, magnetic saturation was often neglected. Moreover, the rub impact between the rotor and stator is inevitable when the amplitude of the rotor vibration exceeds the air-gap. This paper aims to propose a general electromagnetic excitation model for electrical machines. First, a general model which takes the magnetic saturation and rub impact into consideration is proposed and validated by the finite element method and reference. The dynamic equations of a Jeffcott rotor system with electromagnetic excitation and mass imbalance are presented. Then, the effects of pole-pair number and rubbing parameters on vibration amplitude are studied and approaches restraining the amplitude are put forward. Finally, the influences of mass eccentricity, resultant magnetomotive force (MMF), stiffness coefficient, damping coefficient, contact stiffness and friction coefficient on the stability of the rotor system are investigated through the Floquet theory, respectively. The amplitude jumping phenomenon is observed in a synchronous generator for different pole-pair numbers. The changes of design parameters can alter the stability states of the rotor system and the range of parameter values forms the zone of stability, which lays helpful suggestions for the design and application of the electrical machines.

  8. Hand rub dose needed for a single disinfection varies according to product: a bias in benchmarking using indirect hand hygiene indicator.

    PubMed

    Girard, Raphaële; Aupee, Martine; Erb, Martine; Bettinger, Anne; Jouve, Alice

    2012-12-01

    The 3ml volume currently used as the hand hygiene (HH) measure has been explored as the pertinent dose for an indirect indicator of HH compliance. A multicenter study was conducted in order to ascertain the required dose using different products. The average contact duration before drying was measured and compared with references. Effective hand coverage had to include the whole hand and the wrist. Two durations were chosen as points of reference: 30s, as given by guidelines, and the duration validated by the European standard EN 1500. Each product was to be tested, using standardized procedures, by three nosocomial infection prevention teams, for three different doses (3, 2 and 1.5ml). Data from 27 products and 1706 tests were analyzed. Depending on the product, the dose needed to ensure a 30-s contact duration in 75% of tests ranging from 2ml to more than 3ml, and to ensure a contact duration exceeding the EN 1500 times in 75% of tests ranging from 1.5ml to more than 3ml. The aftermath interpretation is the following: if different products are used, the volume utilized does not give an unbiased estimation of the HH compliance. Other compliance evaluation methods remain necessary for efficient benchmarking. Copyright © 2012 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.

  9. Hand hygiene technique quality evaluation in nursing and medicine students of two academic courses 1

    PubMed Central

    Škodová, Manuela; Gimeno-Benítez, Alfredo; Martínez-Redondo, Elena; Morán-Cortés, Juan Francisco; Jiménez-Romano, Ramona; Gimeno-Ortiz, Alfredo

    2015-01-01

    Abstract Objective: because they are health professionals, nursing and medical students' hands during internships can function as a transmission vehicle for hospital-acquired infections. Method: a descriptive study with nursing and medical degree students on the quality of the hand hygiene technique, which was assessed via a visual test using a hydroalcoholic solution marked with fluorescence and an ultraviolet lamp. Results: 546 students were assessed, 73.8% from medicine and 26.2% from nursing. The area of the hand with a proper antiseptic distribution was the palm (92.9%); areas not properly scrubbed were the thumbs (55.1%). 24.7% was very good in both hands, 29.8% was good, 25.1% was fair, and 20.3% was poor. The worst assessed were the male, nursing and first year students. There were no significant differences in the age groups. Conclusions: hand hygiene technique is not applied efficiently. Education plays a key role in setting a good practice base in hand hygiene, theoretical knowledge, and in skill development, as well as good practice reinforcement. PMID:26444174

  10. [Modified gloving technique for vacuum therapy in the hand].

    PubMed

    Polykandriotis, E; Kneser, U; Kopp, J; Horch, R E

    2006-04-01

    During the last 10 years sub-atmospheric pressure dressings (Topical Negative Pressure Therapy = TNP) has become a well accepted standard therapeutic modality in the management of acute and chronic wounds. However, in the hand and the fingers TNP treatment is not as an established method as elsewhere in the body. This is mostly due to difficulties in the technique of sealing wounds near the interdigital folds, especially when the interdigital folds are affected themselves. Over a period of 36 months we treated 9 extensive open wounds of the hand with the TNP dressing procedure. To optimize the effective sealing procedure several methods of closure were applied: sterile vinyl gloves, split V.A.C. gel-straps and the "Sandwich"-principle. In all cases we were able to achieve a tight vacuum sealing with the use of our vinyl or latex free surgical glove as an aid to cover the interdigital spaces. There was a rapid and complete remission of the symptoms in terms of edema, redness, tenderness and range of motion. The indication spectrum encompassed infection control, temporary coverage of exposed bone or tendons, intermittent irrigation with local antiseptics as well as wound preconditioning before skin grafting or flap coverage. For the definite closure or coverage a second operation was necessary in all cases. The TNP-dressing can be securely achieved even in wounds encompassing the interdigital folds or adjacent to the in digital spaces with a modified surgical gloving technique to aid the standard sealing foil. It is a suitable principle for the management of severe hand infections with a reduction of clinical symptoms, reduction of the frequency of dressing changes compared to open approaches and a significant amelioration in the quality of life both for patients and health care personnel.

  11. A Reality Rub Crisis Intervention: "I Wish There Was a Law against Belts."

    ERIC Educational Resources Information Center

    Long, Nicholas J.; Techet, Bonnie

    1994-01-01

    Presents Life Space Interview (LSI) or Life Space Crisis Intervention (LSCI) with second-grade student from threatening home environment. Uses Reality Rub Intervention Interview, focusing on five variations: distorted perceptions, tunnel vision, faulty thinking, avoidance, and alibi. Describes incident that led to intervention, interview itself,…

  12. B11 NMR in the layered diborides OsB2 and RuB2

    NASA Astrophysics Data System (ADS)

    Suh, B. J.; Zong, X.; Singh, Y.; Niazi, A.; Johnston, D. C.

    2007-10-01

    B11 nuclear magnetic resonance (NMR) measurements have been performed on B11 enriched OsB2 and RuB2 polycrystalline powder samples in an external field of 4.7T and in the temperature range, 4.2KRuB2 , respectively. The experimental results indicate that a p character dominates the conduction electron wave function at the B site with a negligibly small s character in both compounds.

  13. Healthcare professionals’ hand hygiene knowledge and beliefs in the United Arab Emirates

    PubMed Central

    Ng, Wai Khuan; Shaban, Ramon Z.; van de Mortel, Thea

    2016-01-01

    Background: Hand hygiene at key moments during patient care is considered an important infection prevention and control measure to reduce healthcare-associated infections. While there is extensive research in Western settings, there is little in the United Arab Emirates where particular cultural and religious customs are thought to influence hand hygiene behaviour. Aim: To examine the hand hygiene knowledge and beliefs of health professionals at a tertiary care hospital in the United Arab Emirates. Methods: A mixed methods design employed a survey followed by focus groups with nurses and doctors. Findings: A total of 109 participants (13.6%) completed the survey: 96 nurses (88%) and 13 doctors (12%). Doctors’ hand hygiene knowledge was slightly higher than that of nurses (78.5% versus 73.5%). There was no significant difference in scores on the hand hygiene beliefs scale between nurses (M = 103.06; SD = 8.0) and doctors (M = 99.00; SD = 10.53; t (80) = 1.55; p = 0.13, two-tailed). Seven categories emerged following transcript analysis. Discussion: Hand hygiene knowledge scores suggest further hand hygiene education is required, especially on alcohol-based hand rub use. Addressing doctors’ beliefs is particularly important given the leadership roles that doctors play in healthcare settings. PMID:28989517

  14. Hand washing with soap and water together with behavioural recommendations prevents infections in common work environment: an open cluster-randomized trial.

    PubMed

    Savolainen-Kopra, Carita; Haapakoski, Jaason; Peltola, Piia A; Ziegler, Thedi; Korpela, Terttu; Anttila, Pirjo; Amiryousefi, Ali; Huovinen, Pentti; Huvinen, Markku; Noronen, Heikki; Riikkala, Pia; Roivainen, Merja; Ruutu, Petri; Teirilä, Juha; Vartiainen, Erkki; Hovi, Tapani

    2012-01-16

    Hand hygiene is considered as an important means of infection control. We explored whether guided hand hygiene together with transmission-limiting behaviour reduces infection episodes and lost days of work in a common work environment in an open cluster-randomized 3-arm intervention trial. A total of 21 clusters (683 persons) were randomized to implement hand hygiene with soap and water (257 persons), with alcohol-based hand rub (202 persons), or to serve as a control (224 persons). Participants in both intervention arms also received standardized instructions on how to limit the transmission of infections. The intervention period (16 months) included the emergence of the 2009 influenza pandemic and the subsequent national hand hygiene campaign influencing also the control arm. In the total follow-up period there was a 6.7% reduction of infection episodes in the soap-and water arm (p = 0.04). Before the onset of the anti-pandemic campaign, a statistically significant (p = 0.002) difference in the mean occurrence of infection episodes was observed between the control (6.0 per year) and the soap-and-water arm (5.0 per year) but not between the control and the alcohol-rub arm (5.6 per year). Neither intervention had a decreasing effect on absence from work. We conclude that intensified hand hygiene using water and soap together with behavioural recommendations can reduce the occurrence of self-reported acute illnesses in common work environment. Surprisingly, the occurrence of reported sick leaves also increased in the soap-and water-arm. ClinicalTrials.gov: NCT00981877 The Finnish Work Environment Fund and the National Institute for Health and Welfare.

  15. Piezoelectric osteotomy in hand surgery: first experiences with a new technique

    PubMed Central

    Hoigne, Dominik J; Stübinger, Stefan; Kaenel, Oliver Von; Shamdasani, Sonia; Hasenboehler, Paula

    2006-01-01

    Background In hand and spinal surgery nerve lesions are feared complications with the use of standard oscillating saws. Oral surgeons have started using a newly developed ultrasound bone scalpel when performing precise osteotomies. By using a frequency of 25–29 kHz only mineralized tissue is cut, sparing the soft tissue. This reduces the risk of nerve lesions. As there is a lack of experience with this technique in the field of orthopaedic bone surgery, we performed the first ultrasound osteotomy in hand surgery. Method While performing a correctional osteotomy of the 5th metacarpal bone we used the Piezosurgery® Device from Mectron [Italy] instead of the usual oscillating saw. We will report on our experience with one case, with a follow up time of one year. Results The cut was highly precise and there were no vibrations of the bone. The time needed for the operation was slightly longer than the time needed while using the usual saw. Bone healing was good and at no point were there any neurovascular disturbances. Conclusion The Piezosurgery® Device is useful for small long bone osteotomies. Using the fine tip enables curved cutting and provides an opportunity for new osteotomy techniques. As the device selectively cuts bone we feel that this device has great potential in the field of hand- and spinal surgery. PMID:16611362

  16. Hand contamination during routine care in medical wards: the role of hand hygiene compliance.

    PubMed

    Monistrol, Olga; López, M Liboria; Riera, Montserrat; Font, Roser; Nicolás, Carme; Escobar, Miguel Angel; Freixas, Núria; Garau, Javier; Calbo, Esther

    2013-04-01

    The hands of healthcare workers (HCWs) are the most common vehicle for the transmission of micro-organisms from patient to patient and within the healthcare environment. The aim of this study was to evaluate the impact of a multimodal campaign on the type and amount of resident and transient flora and the presence of potential risk factors for hand contamination during routine care. A before-after (PRE and POST periods) interventional study was carried out in medical wards of a tertiary care hospital. Eighty-nine samples were analysed. Samples were cultured immediately before patient contact using a glove-juice method. Data collected included socio-demographic and risk factors for hand contamination. Flora was measured as log10 c.f.u. ml(-1) and evaluated by comparing median values in the PRE and POST periods. Transient flora was isolated from the hands of 67.4 and 46.1 % of HCWs in the PRE and POST periods, respectively (P<0.001). Enterobacteriaceae, Pseudomonas spp. and meticillin-sensitive Staphylococcus aureus were the predominant contaminants. Resident flora was isolated from 92.1 % of HCWs in the PRE period and from 70.8 % in the POST period (P<0.001). The meticillin-resistant coagulase-negative staphylococci log10 c.f.u. count ml(-1) decreased from 1.96 ± 1.2 to 0.89 ± 1.2 (mean ± s d; P<0.001), and the global flora count decreased from 2.77 ± 1.1 to 1.56 ± 1.4 (P<0.001). In the POST period, the wearing of fewer rings (P<0.001), shorter fingernail length (P = 0.008), a shorter time since recent hand hygiene (HH) (P = 0.007) and an increased use of alcohol-based hand rub instead of soap (P<0.001) were documented. The HH multimodal strategy reduced the number of risk factors and the level of HCW hand contamination.

  17. Outbreaks where food workers have been implicated in the spread of foodborne disease. Part 10. Alcohol-based antiseptics for hand disinfection and a comparison of their effectiveness with soaps.

    PubMed

    Todd, Ewen C D; Michaels, Barry S; Holah, John; Smith, Debra; Greig, Judy D; Bartleson, Charles A

    2010-11-01

    Alcohol compounds are increasingly used as a substitute for hand washing in health care environments and some public places because these compounds are easy to use and do not require water or hand drying materials. However, the effectiveness of these compounds depends on how much soil (bioburden) is present on the hands. Workers in health care environments and other public places must wash their hands before using antiseptics and/or wearing gloves. However, alcohol-based antiseptics, also called rubs and sanitizers, can be very effective for rapidly destroying some pathogens by the action of the aqueous alcohol solution without the need for water or drying with towels. Alcohol-based compounds seem to be the most effective treatment against gram-negative bacteria on lightly soiled hands, but antimicrobial soaps are as good or better when hands are more heavily contaminated. Instant sanitizers have no residual effect, unlike some antimicrobial soaps that retain antimicrobial activity after the hygienic action has been completed, e.g., after hand washing. Many alcohol-based hand rubs have antimicrobial agents added to them, but each formulation must be evaluated against the target pathogens in the environment of concern before being considered for use. Wipes also are widely used for quick cleanups of hands, other body parts, and surfaces. These wipes often contain alcohol and/or antimicrobial compounds and are used for personal hygiene where water is limited. However, antiseptics and wipes are not panaceas for every situation and are less effective in the presence of more than a light soil load and against most enteric viruses.

  18. Quality improvement program for the B83 bomb hand truck

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loll, M.B.; Buck, S.A.

    1998-04-01

    This report describes the problems, issues, and history of the H1347 bomb hand truck for the B83 bomb after the bomb was put into stockpile in the mid-1980s. Major issues that were reported in Unsatisfactory Reports (URs) were cracking problems on stacking fixture welds, cracked welds on the caster bracket receptacles on the cradle, cracked caster mounting brackets, casters unlocking from the swivel lock position, and caster tires rubbing and binding on the stacking frame. Resolution of these and other problems is described. The introduction of the H695B storage-only bomb hand truck to alleviate a shortage of bomb hand trucksmore » in the mid-1990s is described. The development and qualification of the H1347A bomb hand truck as a replacement for the H695 B is covered. The results from load test evaluations on the stacking fixture, cradle, and casters for the H1347 are described along with towing results on one and two-high stack configurations of B83 bombs in bomb hand trucks. New towing and truck/trailer transport procedures are described. Development, evaluation, and production recommendations for a stronger caster mounting bracket are described.« less

  19. A quasi-experimental study to determine the effects of a multifaceted educational intervention on hand hygiene compliance in a radiography unit.

    PubMed

    O'Donoghue, Margaret; Ng, Suk-Hing; Suen, Lorna Kp; Boost, Maureen

    2016-01-01

    Whilst numerous studies have investigated nurses' compliance with hand hygiene and use of alcohol-based hand rub (ABHR), limited attention has been paid to these issues in allied health staff. Reports have linked infections to breaches in infection control in the radiography unit (RU). With advances in medical imaging, a higher proportion of patients come into contact with RU staff increasing the need for good hand hygiene compliance. This study aimed to evaluate effectiveness on compliance of an intervention to improve awareness of hand hygiene in the RU of a district hospital. A quasi-experimental study design including questionnaires assessing knowledge and attitudes of hand hygiene and direct observation of participants was used to evaluate an educational programme on hand hygiene of the RU of a large district hospital. All healthcare workers (HCW), comprising 76 radiographers, 17 nurses, and nine healthcare assistants (HCA), agreed to participate in the study. Of these, 85 completed the initial and 76 the post-test anonymous questionnaire. The hand hygiene compliance of all 102 HCW was observed over a 3-week period prior to and after the intervention. The 2-month intervention consisted of talks on hand hygiene and benefits of ABHR, provision of visual aids, wall-mounted ABHR dispensers, and personal bottles of ABHR. Before the intervention, overall hand hygiene compliance was low (28.9 %). Post-intervention, compliance with hand hygiene increased to 51.4 %. This improvement was significant for radiographers and HCA. Additionally, knowledge and attitudes improved in particular, understanding that ABHR can largely replace handwashing and there is a need to perform hand hygiene after environmental contact. The increased use of ABHR allowed HCW to feel they had enough time to perform hand hygiene. The educational intervention led to increased awareness of hand hygiene opportunities and better acceptance of ABHR use. The reduced time needed to perform hand

  20. Numerical results of the influence of thermal effects on the turbo machine rotordynamics induced by light-rubs against a brush seal

    NASA Astrophysics Data System (ADS)

    Fay, R.; Kreuzer, D.; Liebich, R.; Wiedemann, T.; Werner, S.

    2018-07-01

    Brush seals are an efficient alternative for labyrinth seals in turbomachinery. Brush seals show on the one hand a better leakage reduction in relation to their axial length and hence allow a shorter design of the machinery. On the other hand, the particularly small gap between bristles and the engine shaft increases the risk of rotor-stator-contact. The flexible brush seals induces basically light-rubs that in some cases might lead to spiral vibrations and thermal mechanical instabilities. Spiral vibrations are caused by a thermal deflection of the rotor induced by a heat flow into the shaft. To predict areas of instabilites during the design process a tool was developed at the Berlin Institute of Technology. The model combines a rotor dynamic model and a thermal model. The thermal system is reduced using a stationary solution, so that the final system, on which the stability analysis is performed, is comparable to the established Kellenberger model. The paper presents the numerical model for the predictions of unstable regions depending on rotational speed. This is illustrated by means of an example of an axial compressor manufactured by MAN Diesel & Turbo.

  1. [A multimodal strategy to improve adherence to hand hygiene in a university hospital].

    PubMed

    Fariñas-Alvarez, C; Portal-María, T; Flor-Morales, V; Aja-Herrero, A; Fabo-Navarro, M; Lanza-Marín, S; Lobeira-Rubio, R; Polo-Hernández, N; Sixto-Montero, M; Moreta-Sánchez, R; Ballesteros-Sanz, M Á; Yañez-San Segundo, L; Bartalome-Pacheco, M J; Armiñanzas-Castillo, C

    Within the framework of the PaSQ (Patient Safety and Quality care) Project, this hospital decided to implement a multifaceted hospital-wide Hand Hygiene (HH) intervention based on a multimodal WHO approach over one year, focusing on achieving a sustained change in HH cultural change in this hospital. Setting: University Hospital Marqués de Valdecilla, Santander (Spain), a tertiary hospital with 900 beds. Intervention period: 2014. An action plan was developed that included the implementation of activities in each component of the 5-step multimodal intervention. An observation/feedback methodology was used that included the provision of performance and results feedback to the staff. A 3/3 strategy (non-blinded direct observation audits performed during 3 randomised days every 3 weeks with pro-active corrective actions at the end of each observation period). HH compliance, alcohol-based hand-rub (ABHR) consumption, and rate of MRSA infection, were monitored during the intervention. Hospital ABHR consumption increased during the study period: from 17.5 to 19.7mL/patient-days. In the intervention units, this consumption was 24.8mL pre-intervention, 42.5mL during the intervention, and 30.4mL two months post-intervention. There were 137 evaluation periods in 30 different days, in which a total of 737 health-care workers were observed and 1,870 HH opportunities. HH compliance was 54.5%, ranging between 44.8% and 69.9%. The incidence of MRSA infection decreased during the intervention in the selected units, from 13.2 infections per 10,000 patient-days pre-intervention to 5.7 three months post-intervention. Our HH strategy, supported by a 3/3 strategy increased alcohol-based hand-rub consumption and compliance. A reduction in MRSA infections was observed. Copyright © 2016 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Hand washing with soap and water together with behavioural recommendations prevents infections in common work environment: an open cluster-randomized trial

    PubMed Central

    2012-01-01

    Background Hand hygiene is considered as an important means of infection control. We explored whether guided hand hygiene together with transmission-limiting behaviour reduces infection episodes and lost days of work in a common work environment in an open cluster-randomized 3-arm intervention trial. Methods A total of 21 clusters (683 persons) were randomized to implement hand hygiene with soap and water (257 persons), with alcohol-based hand rub (202 persons), or to serve as a control (224 persons). Participants in both intervention arms also received standardized instructions on how to limit the transmission of infections. The intervention period (16 months) included the emergence of the 2009 influenza pandemic and the subsequent national hand hygiene campaign influencing also the control arm. Results In the total follow-up period there was a 6.7% reduction of infection episodes in the soap-and water arm (p = 0.04). Before the onset of the anti-pandemic campaign, a statistically significant (p = 0.002) difference in the mean occurrence of infection episodes was observed between the control (6.0 per year) and the soap-and-water arm (5.0 per year) but not between the control and the alcohol-rub arm (5.6 per year). Neither intervention had a decreasing effect on absence from work. Conclusions We conclude that intensified hand hygiene using water and soap together with behavioural recommendations can reduce the occurrence of self-reported acute illnesses in common work environment. Surprisingly, the occurrence of reported sick leaves also increased in the soap-and water-arm. Trial Registration ClinicalTrials.gov: NCT00981877 Source of funding The Finnish Work Environment Fund and the National Institute for Health and Welfare. PMID:22243622

  3. Pointing and pantomime in wild apes? Female bonobos use referential and iconic gestures to request genito-genital rubbing

    PubMed Central

    Douglas, Pamela Heidi; Moscovice, Liza R.

    2015-01-01

    Referential and iconic gesturing provide a means to flexibly and intentionally share information about specific entities, locations, or goals. The extent to which nonhuman primates use such gestures is therefore of special interest for understanding the evolution of human language. Here, we describe novel observations of wild female bonobos (Pan paniscus) using referential and potentially iconic gestures to initiate genito-genital (GG) rubbing, which serves important functions in reducing social tension and facilitating cooperation. We collected data from a habituated community of bonobos at Luikotale, DRC, and analysed n = 138 independent gesture bouts made by n = 11 females. Gestures were coded in real time or from video. In addition to meeting the criteria for intentionality, in form and function these gestures resemble pointing and pantomime–two hallmarks of human communication–in the ways in which they indicated the relevant body part or action involved in the goal of GG rubbing. Moreover, the gestures led to GG rubbing in 83.3% of gesture bouts, which in turn increased tolerance in feeding contexts between the participants. We discuss how biologically relevant contexts in which individuals are motivated to cooperate may facilitate the emergence of language precursors to enhance communication in wild apes. PMID:26358661

  4. Factors associated with hand hygiene practices in two neonatal intensive care units.

    PubMed

    Cohen, Bevin; Saiman, Lisa; Cimiotti, Jeannie; Larson, Elaine

    2003-06-01

    To determine whether hand hygiene practices differ between levels of contact with neonates; to characterize the hand hygiene practices of different types of personnel; and to compare hand hygiene practices in neonatal intensive care units (NICUs) using different products. Research assistants observed staff hand hygiene practices during 38 sessions in two NICUs. Patient touches were categorized as touching within the neonates' environment but only outside the Isolette (Level 1), touching within the Isolette but not the neonate directly (Level 2) or directly touching the neonate (Level 3). Hand hygiene practices for each touch were categorized into five groups: cleaned hands and new gloves; uncleaned hands and new gloves; used gloves; clean hands and no gloves; uncleaned hands and no gloves. Research assistants observed 1472 touches. On average each neonate or his or her immediate environment was touched 78 times per shift. Nurses (P = 0.001), attending physicians (P = 0.02) and physicians-in-training (P = 0.03) were more likely to use appropriate practices during Level 3 touches, but only 22.8% of all touches were with cleaned and/or newly gloved hands. The mean number of direct touches by staff members with cleaned hands was greater in the NICU using an alcohol-based hand rub than in the NICU using antimicrobial soap (P < 0.01). Hand hygiene was suboptimal in this high risk setting; administrative action and improved products may be needed to assure acceptable practice. In this study use of an alcohol-based product was associated with significantly improved hand hygiene and should be encouraged, as recommended in the new CDC hand hygiene guideline.

  5. The effect of a novel square-profile hand rim on propulsion technique of wheelchair tennis players.

    PubMed

    de Groot, Sonja; Bos, Femke; Koopman, Jorine; Hoekstra, Aldo E; Vegter, Riemer J K

    2018-09-01

    The purpose of this study was to investigate the effect of a square-profile hand rim (SPR) on propulsion technique of wheelchair tennis players. Eight experienced wheelchair tennis players performed two sets of three submaximal exercise tests and six sprint tests on a wheelchair ergometer, once with a regular rim (RR) and once with a SPR. Torque and velocity were measured continuously and power output and timing variables were calculated. No significant differences were found in propulsion technique between the RR and SPR during the submaximal tests. When sprinting with the racket, the SPR showed a significantly lower overall speed (9.1 vs. 9.8 m s -1 ), maximal speed (10.5 vs. 11.4 m s -1 ), and maximal acceleration (18.6 vs. 10.9 m s -2 ). The SPR does not seem to improve the propulsion technique when propelling a wheelchair with a tennis racket in the hand. However, the results gave input for new hand rim designs for wheelchair tennis. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. A Comparison of Techniques for Camera Selection and Hand-Off in a Video Network

    NASA Astrophysics Data System (ADS)

    Li, Yiming; Bhanu, Bir

    Video networks are becoming increasingly important for solving many real-world problems. Multiple video sensors require collaboration when performing various tasks. One of the most basic tasks is the tracking of objects, which requires mechanisms to select a camera for a certain object and hand-off this object from one camera to another so as to accomplish seamless tracking. In this chapter, we provide a comprehensive comparison of current and emerging camera selection and hand-off techniques. We consider geometry-, statistics-, and game theory-based approaches and provide both theoretical and experimental comparison using centralized and distributed computational models. We provide simulation and experimental results using real data for various scenarios of a large number of cameras and objects for in-depth understanding of strengths and weaknesses of these techniques.

  7. The defence technique in Tai Chi Push Hands: a case study.

    PubMed

    Chen, Hui-Chuan; Cheng, Kuang-You B; Liu, Yu-Jen; Chiu, Hung-Ta; Cheng, Kuang-Yu

    2010-12-01

    Developed from traditional Chinese martial arts, Tai Chi exercise includes different forms and interactive Push Hands but biomechanical analyses have focused on the former only. To analyse the techniques of Push Hands, an experienced master was asked to defend pushing by four opponents. Movements were videotaped and digitized using a motion analysis system. Surface electrodes were used to record the electromyographic activity of ten muscle groups. Two force plates were used to measure the ground reaction force on each foot. Inexperienced individuals performed the same procedure to serve as the control group. The results indicate that the master adopted a postural adjustment to maintain balance. A clear shift of body weight from the front to the rear foot and mediolateral displacement of the centre of gravity was observed. Low electromyographic activity was observed in the upper body muscle groups, while high electromyographic activity was observed in the right rectus femoris and very high activity in the left rectus femoris during the defence. All inexperienced participants lost their balance in resisting pushing. It is concluded that the Tai Chi defensive technique includes a subtle postural adjustment that slightly changes the pushing force direction, and allows the rear leg to resist the incoming force.

  8. Texture Rubbings

    ERIC Educational Resources Information Center

    Szekely, George

    2011-01-01

    As hands-on environmental observers, children use printing to save and share "treasures" they find. In this article, the author shares thoughts which are based on observing what children find valuable and worth saving, and the printmaking processes used to "lift" images from their finds.

  9. Hand hygiene with soap and water is superior to alcohol rub and antiseptic wipes for removal of Clostridium difficile.

    PubMed

    Oughton, Matthew T; Loo, Vivian G; Dendukuri, Nandini; Fenn, Susan; Libman, Michael D

    2009-10-01

    To evaluate common hand hygiene methods for efficacy in removing Clostridium difficile. Randomized crossover comparison among 10 volunteers with hands experimentally contaminated by nontoxigenic C. difficile. Interventions included warm water with plain soap, cold water with plain soap, warm water with antibacterial soap, antiseptic hand wipes, alcohol-based handrub, and a control involving no intervention. All interventions were evaluated for mean reduction in colony-forming units (CFUs) under 2 contamination protocols: "whole hand" and "palmar surface." Results were analyzed according to a Bayesian approach, by using hierarchical models adjusted for multiple observations. Under the whole-hand protocol, the greatest adjusted mean reductions were achieved by warm water with plain soap (2.14 log(10) CFU/mL [95% credible interval (CrI), 1.74-2.54 log(10) CFU/mL]), cold water with plain soap (1.88 log(10) CFU/mL [95% CrI, 1.48-2.28 log(10) CFU/mL), and warm water with antibacterial soap (1.51 log(10) CFU/mL [95% CrI, 1.12-1.91 log(10) CFU/mL]), followed by antiseptic hand wipes (0.57 log(10) CFU/mL [95% CrI, 0.17-0.96 log(10) CFU/mL]). Alcohol-based handrub (0.06 log(10) CFU/mL [95% CrI, -0.34 to 0.45 log(10) CFU/mL]) was equivalent to no intervention. Under the palmar surface protocol, warm water with plain soap, cold water with plain soap, and warm water with antibacterial soap again yielded the greatest mean reductions, followed by antiseptic hand wipes (26.6, 26.6, 26.6, and 21.9 CFUs per plate, respectively), when compared with alcohol-based handrub. Hypothenar (odds ratio, 10.98 [95% CrI, 1.96-37.65]) and thenar (odds ratio, 6.99 [95% CrI, 1.25-23.41]) surfaces were more likely than fingertips to remain heavily contaminated after handwashing. Handwashing with soap and water showed the greatest efficacy in removing C. difficile and should be performed preferentially over the use of alcohol-based handrubs when contact with C. difficile is suspected or likely.

  10. Non-contact XUV metrology of Ru/B4C multilayer optics by means of Hartmann wavefront analysis.

    PubMed

    Ruiz-Lopez, Mabel; Dacasa, Hugo; Mahieu, Benoit; Lozano, Magali; Li, Lu; Zeitoun, Philippe; Bleiner, Davide

    2018-02-20

    Short-wavelength imaging, spectroscopy, and lithography scale down the characteristic length-scale to nanometers. This poses tight constraints on the optics finishing tolerances, which is often difficult to characterize. Indeed, even a tiny surface defect degrades the reflectivity and spatial projection of such optics. In this study, we demonstrate experimentally that a Hartmann wavefront sensor for extreme ultraviolet (XUV) wavelengths is an effective non-contact analytical method for inspecting the surface of multilayer optics. The experiment was carried out in a tabletop laboratory using a high-order harmonic generation as an XUV source. The wavefront sensor was used to measure the wavefront errors after the reflection of the XUV beam on a spherical Ru/B 4 C multilayer mirror, scanning a large surface of approximately 40 mm in diameter. The results showed that the technique detects the aberrations in the nanometer range.

  11. Case Report: The casting motion to mobilize stiffness technique for rehabilitation after a crush and degloving injury of the hand.

    PubMed

    Midgley, Robyn

    2016-01-01

    Case report. This case report describes the use of the casting motion to mobilize stiffness (CMMS) technique in the management of a crush and degloving injury of the hand. The patient was unable to attend multiple hand therapy sessions due to geographic constraints. The CMMS technique involved the application of a nonremovable plaster of paris cast that selectively immobilizes proximal joints in an ideal position while constraining distal joints to direct desired motion over a long period. This uses active motion only. Traditional hand therapy techniques or modalities are not used. This treatment approach was beneficial to the patient as a minimum of 2 appointments per month were needed to regain functional hand use. To document the use of the CMMS technique as an effective treatment approach in the management of a crush and degloving injury of the hand. The CMMS technique was applied to the patient's left (nondominant) hand 8 weeks after injury. The technique's aim was to improve the 30° flexion deformity of the left wrist and flexion contractures of the index, middle, and ring fingers with a total active motion of 0°. Orthotic devices and traditional therapy were applied once joint stiffness was resolved, and a normal pattern of motion was reinstated. At 6 months, substantial improvement was noted in wrist as well as metacarpophalangeal and interphalangeal joints. Total active motion exceeded 170° in all fingers excellent functional outcome resulted as measured with the upper limb functional index short form-10. The upper limb functional index increased from 0% to 55% of preinjury status (or capacity) over the 18 months of therapy. Brief immobilization through casting causes certain functional losses, but these are temporary and reversible. Finger stiffness, edema, and tissue fibrosis were successfully managed with the CMMS technique without the need for attendance at multiple hand therapy sessions. Level V. Copyright © 2016 Hanley & Belfus. Published by

  12. Hand hygiene compliance in transplant and other special patient groups: an observational study.

    PubMed

    Graf, Karolin; Ott, Ella; Wolny, Michael; Tramp, Nadine; Vonberg, Ralf-Peter; Haverich, Axel; Chaberny, Iris Freya

    2013-06-01

    This study evaluates hand hygiene behavior of health care workers in a German university hospital stratified for treatment of special patient groups (eg, transplant patients). From 2008 to 2010, comprehensive education and training of all health care workers was implemented to improve hand hygiene compliance. Consumption rates of alcohol-based hand rub and gloves were collected and evaluated. Of the 5,647 opportunities of hand disinfection evaluated, 1,607 occurred during care for transplant patients. To our knowledge, this is the largest survey of hand hygiene compliance in special patient groups on intensive care units in a university hospital in Germany. Health care workers on surgical intensive care units showed lower hand hygiene compliance compared with health care workers on other types of intensive care units. Compliance toward hand hygiene was significantly higher on hemato-oncologic and pediatric wards. In general, hand disinfection was performed significantly more frequently after an intervention than before (P < .05, 95% confidence interval: 1.24-1.84). Overall, there was no significant difference in hand hygiene compliance when caring for transplant patients or other patients (odds ratio, 1.16; 95% confidence interval: 0.95-1.42). Nurse's and physician's hand hygiene compliance improved because of education. Hand hygiene compliance is not increased in the care for transplant patients (despite their predisposition for nosocomial infections) compared with other patients. Additional studies will be necessary to further investigate these findings. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  13. Rubbing skin with nylon towels as a major cause of pseudomonas folliculitis in a Japanese population.

    PubMed

    Teraki, Yuichi; Nakamura, Kaori

    2015-01-01

    Pseudomonas folliculitis (PF) is a community-acquired skin infection, which develops after exposure to contaminated water such as whirlpools, swimming pools, water slides and hot tubs. In Japan, this condition has been sporadically reported, often in association with bathing; however, the exact cause of PF in the Japanese population remains unclear. In this study, we retrospectively reviewed 10 patients with PF diagnosed at our dermatology clinic (two males and eight females). Four patients had recurrences over 1-3 years. Notably, eight of the 10 patients were rubbing their bodies with nylon towels or sponges placed in the bathrooms during bathing. Pseudomonas aeruginosa was isolated from the nylon towels used in two of the two patients examined. Discontinued use of nylon towels resulted in prompt resolution of PF and no recurrence in all cases. Our observation suggests that rubbing the skin with nylon towels contaminated with P. aeruginosa was a major cause of PF in a Japanese population. © 2014 Japanese Dermatological Association.

  14. Investigations on bending-torsional vibrations of rotor during rotor-stator rub using Lagrange multiplier method

    NASA Astrophysics Data System (ADS)

    Mokhtar, Md Asjad; Kamalakar Darpe, Ashish; Gupta, Kshitij

    2017-08-01

    The ever-increasing need of highly efficient rotating machinery causes reduction in the clearance between rotating and non-rotating parts and increase in the chances of interaction between these parts. The rotor-stator contact, known as rub, has always been recognized as one of the potential causes of rotor system malfunctions and a source of secondary failures. It is one of few causes that influence both lateral and torsional vibrations. In this paper, the rotor stator interaction phenomenon is investigated in the finite element framework using Lagrange multiplier based contact mechanics approach. The stator is modelled as a beam that can respond to axial penetration and lateral friction force during the contact with the rotor. It ensures dynamic stator contact boundary and more realistic contact conditions in contrast to most of the earlier approaches. The rotor bending-torsional mode coupling during contact is considered and the vibration response in bending and torsion are analysed. The effect of parameters such as clearance, friction coefficient and stator stiffness are studied at various operating speeds and it has been found that certain parameter values generate peculiar rub related features. Presence of sub-harmonics in the lateral vibration frequency spectra are prominently observed when the rotor operates near the integer multiple of its lateral critical speed. The spectrum cascade of torsional vibration shows the presence of bending critical speed along with the larger amplitudes of frequencies close to torsional natural frequency of the rotor. When m × 1/n X frequency component of rotational frequency comes closer to the torsional natural frequency, stronger torsional vibration amplitude is noticed in the spectrum cascade. The combined information from the stator vibration and rotor lateral-torsional vibration spectral features is proposed for robust rub identification.

  15. Room temperature rubbing for few-layer two-dimensional thin flakes directly on flexible polymer substrates

    PubMed Central

    Yu, Yan; Jiang, Shenglin; Zhou, Wenli; Miao, Xiangshui; Zeng, Yike; Zhang, Guangzu; Liu, Sisi

    2013-01-01

    The functional layers of few-layer two-dimensional (2-D) thin flakes on flexible polymers for stretchable applications have attracted much interest. However, most fabrication methods are “indirect” processes that require transfer steps. Moreover, previously reported “transfer-free” methods are only suitable for graphene and not for other few-layer 2-D thin flakes. Here, a friction based room temperature rubbing method is proposed for fabricating different types of few-layer 2-D thin flakes (graphene, hexagonal boron nitride (h-BN), molybdenum disulphide (MoS2), and tungsten disulphide (WS2)) on flexible polymer substrates. Commercial 2-D raw materials (graphite, h-BN, MoS2, and WS2) that contain thousands of atom layers were used. After several minutes, different types of few-layer 2-D thin flakes were fabricated directly on the flexible polymer substrates by rubbing procedures at room temperature and without any transfer step. These few-layer 2-D thin flakes strongly adhere to the flexible polymer substrates. This strong adhesion is beneficial for future applications. PMID:24045289

  16. Bone-lengthening for symbrachydactyly of the hand with the technique of callus distraction.

    PubMed

    Miyawaki, Takeshi; Masuzawa, Genzo; Hirakawa, Masahiko; Kurihara, Kunihiro

    2002-06-01

    Bone-lengthening in the hand and foot is a relatively new application for distraction osteogenesis. We present the operative treatment and postoperative outcome for four patients with M ller type-D symbrachydactyly of the hand who underwent metacarpal lengthening with use of a distraction device to establish pinch function. Four patients who underwent distraction osteogenesis for the treatment of congenital symbrachydactyly of the hand were evaluated over a thirteen-year period. The nondominant right hand was treated in two patients, and the nondominant left hand was treated in the other two. The patients included three boys and one girl; all patients had the operation between the ages of five and eleven years. Distraction osteogenesis was performed on the fifth metacarpal in one patient and on the fourth and fifth metacarpals in the remaining three, in whom both bones were lengthened simultaneously with use of a single device. Postoperative bone elongation was analyzed with radiographs made at the time of removal of the distractor. The sensory function of the treated fingers and any growth disturbance of the distracted bones were evaluated. The mean duration of distraction was 37.3 days (range, thirty-two to forty-nine days), and the distractor was removed at a mean of eighty-four days after surgery. The bones were lengthened by a mean of 22.3 mm (81.6% of their original length) at a rate of 0.6 mm/day. Pinch function was improved in all patients. On the basis of our limited experience, we found that distraction osteogenesis of the metacarpals was an effective technique for the establishment of pinch function. We also found that an intramedullary Kirschner wire could maintain the alignment of the osteotomized bone. Although distraction requires a longer treatment period, it is apparently more effective than bone-grafting in terms of achieving adequate bone length. Simultaneous lengthening of two metacarpals also was found to be an effective technique.

  17. Comparison between Rinse and Crush-and-Rub Sampling for Aerobic Bacteria Recovery from Hatching Eggs after Sanitization

    USDA-ARS?s Scientific Manuscript database

    This study compared surface and deep eggshell aerobic bacteria recovered by rinse and crush-and-rub sampling methods for commercial hatching eggs after treatments with sanitizers. Eggs were arranged into 5 treatments consisting of three sanitizers, Water, and No-treatment. Sanitizers were Hydrogen...

  18. Gasoline on hands: preliminary study on collection and persistence.

    PubMed

    Darrer, Melinda; Jacquemet-Papilloud, Joëlle; Delémont, Olivier

    2008-03-05

    The identification of an arsonist remains one of the most difficult challenges a fire investigation has to face. Seeking and detection of traces of gasoline could provide a valuable information to link a suspect with an arson scene where gasoline was used to set-up the fire. In this perspective, a first study was undertaken to evaluate a simple, fast and efficient method for collecting gasoline from hands, and to assess its persistence over time. Four collection means were tested: PVC, PE and Latex gloves, as well as humidified filter paper. A statistical assessment of the results indicates that Latex and PVC gloves worn for about 20 min, as well as paper filter rubbed on hands, allow an efficient collection of gasoline applied to hands. Due to ease of manipulation and to a reduced amount of volatile compounds detected from the matrix, PVC gloves were selected for the second set of experiments. The evaluation of the persistence of gasoline on hands was then carried out using two initial quantities (500 and 1000 microl). Collection was made with PVC gloves after 0, 30 min, 1, 2 and 4h, on different volunteers. The results show a common tendency of massive evaporation of gasoline during the first 30 min: a continued but non-linear decrease was observed along different time intervals. The results of this preliminary study are in agreement with other previous researches conducted on the detection of flammable liquid residues on clothes, shoes and skin.

  19. Development of an observational measure of healthcare worker hand-hygiene behaviour: the hand-hygiene observation tool (HHOT).

    PubMed

    McAteer, J; Stone, S; Fuller, C; Charlett, A; Cookson, B; Slade, R; Michie, S

    2008-03-01

    Previous observational measures of healthcare worker (HCW) hand-hygiene behaviour (HHB) fail to provide adequate standard operating procedures (SOPs), accounts of inter-rater agreement testing or evidence of sensitivity to change. This study reports the development of an observational tool in a way that addresses these deficiencies. Observational categories were developed systematically, guided by a clinical guideline, previous measures and pilot hand-hygiene behaviour observations (HHOs). The measure, a simpler version of the Geneva tool, consists of HHOs (before and after low-risk, high-risk or unobserved contact), HHBs (soap, alcohol hand rub, no action, unknown), and type of HCW. Inter-observer agreement for each category was assessed by observation of 298 HHOs and HHBs by two independent observers on acute elderly and intensive care units. Raw agreement (%) and Kappa were 77% and 0.68 for HHB; 83% and 0.77 for HHO; and 90% and 0.77 for HCW. Inter-observer agreement for overall compliance of a group of HCWs was assessed by observation of 1191 HHOs and HHBs by two pairs of independent observers. Overall agreement was good (intraclass correlation coefficient = 0.79). Sensitivity to change was examined by autoregressive time-series modelling of longitudinal observations for 8 months on the intensive therapy unit during an Acinetobacter baumannii outbreak and subsequent strengthening of infection control measures. Sensitivity to change was demonstrated by a rise in compliance from 80 to 98% with an odds ratio of increased compliance of 7.00 (95% confidence interval: 4.02-12.2) P < 0.001.

  20. Impact of a multi-faceted training intervention on the improvement of hand hygiene and gloving practices in four healthcare settings including nursing homes, acute-care geriatric wards and physical rehabilitation units.

    PubMed

    Eveillard, Matthieu; Raymond, Françoise; Guilloteau, Véronique; Pradelle, Marie-Thérèse; Kempf, Marie; Zilli-Dewaele, Marina; Joly-Guillou, Marie-Laure; Brunel, Patrick

    2011-10-01

    To assess the impact of a multi-faceted training program on the compliance with hand hygiene and gloving practices. Hand hygiene is considered as the cornerstone of the prevention of hospital-acquired infections. Several studies have enhanced the poor effectiveness of training programs in improving hand hygiene compliance. A before-after evaluation study. The study was conducted in four healthcare settings before and after an intervention program which included the performance feedback of the first evaluation phase, three six-h training sessions, the assessment of hand hygiene performance with teaching boxes and the organisation of one full-day session devoted to institutional communication around hand hygiene in each setting. Hand hygiene compliance and quality of hand rubbing were evaluated. Hand hygiene opportunities were differentiated into extra-series opportunities (before or after a single contact and before the first contact or after the last contact of a series of consecutive contacts) and intra-series opportunities (from the opportunity following the first contact to the opportunity preceding the last in the same series). Overall, 969 contacts corresponding to 1,470 hand hygiene opportunities (760 during the first phase and 710 during the second) were observed. A significant improvement of observed practices was recorded for the hand hygiene compliance in intra-series opportunities (39·0% vs. 19·0%; p < 10(-5) ), the proportion of gloves worn if indicated (71·4% vs. 52·0%; p < 0·001) and the quality of hand rubbing (85·0% vs. 71·9%; p < 10(-5) ). Some of the performances measured for both hand hygiene and gloving practices were improved. We plan to extend this investigation by performing a qualitative study with experts in behavioural sciences to try improving practices for which adherence was still weak after the training program such as hand hygiene in intra-series opportunities. This study underscored the usefulness of implementing

  1. Costing the Australian National Hand Hygiene Initiative.

    PubMed

    Page, K; Barnett, A G; Campbell, M; Brain, D; Martin, E; Fulop, N; Graves, N

    2014-11-01

    The Australian National Hand Hygiene Initiative (NHHI) is a major patient safety programme co-ordinated by Hand Hygiene Australia (HHA) and funded by the Australian Commission for Safety and Quality in Health Care. The annual costs of running this programme need to be understood to know the cost-effectiveness of a decision to sustain it as part of health services. To estimate the annual health services cost of running the NHHI; the set-up costs are excluded. A health services perspective was adopted for the costing and collected data from the 50 largest public hospitals in Australia that implemented the initiative, covering all states and territories. The costs of HHA, the costs to the state-level infection-prevention groups, the costs incurred by each acute hospital, and the costs for additional alcohol-based hand rub are all included. The programme cost AU$5.56 million each year (US$5.76, £3.63 million). Most of the cost is incurred at the hospital level (65%) and arose from the extra time taken for auditing hand hygiene compliance and doing education and training. On average, each infection control practitioner spent 5h per week on the NHHI, and the running cost per annum to their hospital was approximately AU$120,000 in 2012 (US$124,000, £78,000). Good estimates of the total costs of this programme are fundamental to understanding the cost-effectiveness of implementing the NHHI. This paper reports transparent costing methods, and the results include their uncertainty. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. Microwave-superheated Vics Vapo Rub: an ocular public health danger.

    PubMed

    Fung, Anne E; Oxford, Karen W

    2004-02-01

    To report a case of a microwave-oven superheated petroleum-based liquid causing severe chemical and thermal ocular burns treated successfully with amniotic membrane transplantation. Observational case report. Retrospective review of clinical case. A 77-year-old woman sustained a severe combined chemical and thermal burn from microwave-heated Vicks Vapo-Rub requiring amniotic membrane transplant, with subsequent development of phacomorphic glaucoma, requiring cataract extraction, and bullous keratopathy, requiring penetrating keratoplasty. As microwave oven use becomes more commonplace, the risk of superheating liquids becomes an increasingly significant ocular danger. Continued efforts to educate the public about safe microwave use is necessary. Additionally, amniotic membrane transplantation was found to be effective in managing a combined chemical and thermal ocular burn.

  3. A novel hand-type detection technique with fingerprint sensor

    NASA Astrophysics Data System (ADS)

    Abe, Narishige; Shinzaki, Takashi

    2013-05-01

    In large-scale biometric authentication systems such as the US-Visit (USA), a 10-fingerprints scanner which simultaneously captures four fingerprints is used. In traditional systems, specific hand-types (left or right) are indicated, but it is difficult to detect hand-type due to the hand rotation and the opening and closing of fingers. In this paper, we evaluated features that were extracted from hand images (which were captured by a general optical scanner) that are considered to be effective for detecting hand-type. Furthermore, we extended the knowledge to real fingerprint images, and evaluated the accuracy with which it detects hand-type. We obtained an accuracy of about 80% with only three fingers (index, middle, ring finger).

  4. Analysis of alcohol-based hand sanitizer delivery systems: efficacy of foam, gel, and wipes against influenza A (H1N1) virus on hands.

    PubMed

    Larson, Elaine L; Cohen, Bevin; Baxter, Kathleen A

    2012-11-01

    Minimal research has been published evaluating the effectiveness of hand hygiene delivery systems (ie, rubs, foams, or wipes) at removing viruses from hands. The purposes of this study were to determine the effect of several alcohol-based hand sanitizers in removing influenza A (H1N1) virus, and to compare the effectiveness of foam, gel, and hand wipe products. Hands of 30 volunteers were inoculated with H1N1 and randomized to treatment with foam, gel, or hand wipe applied to half of each volunteer's finger pads. The log(10) count of each subject's treated and untreated finger pads were averaged. Log(10) reductions were calculated from these differences and averaged within treatment group. Between-treatment analysis compared changes from the untreated finger pads using analysis of covariance with treatment as a factor and the average log(10) untreated finger pads as the covariate. Log(10) counts on control finger pads were 2.7-5.3 log(10) of the 50% infectious dose for tissue culture (TCID(50)/0.1 mL) (mean, 3.8 ± 0.5 log(10) TCID(50)/0.1 mL), and treated finger pad counts for all test products were 0.5-1.9 log(10) TCID(50)/0.1 mL (mean, 0.53 ± 0.17 log(10) TCID(50)/0.1 mL). Treatments with all products resulted in a significant reduction in viral titers (>3 logs) at their respective exposure times that were statistically comparable. All 3 delivery systems (foam, gel, and wipe) produced significantly reduced viral counts on hands. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  5. The Hand-Assisted Laparoscopic Approach to Resection of Pancreatic Mucinous Cystic Neoplasms: An Underused Technique?

    PubMed

    Postlewait, Lauren M; Ethun, Cecilia G; McInnis, Mia R; Merchant, Nipun; Parikh, Alexander; Idrees, Kamran; Isom, Chelsea A; Hawkins, William; Fields, Ryan C; Strand, Matthew; Weber, Sharon M; Cho, Clifford S; Salem, Ahmed; Martin, Robert C G; Scoggins, Charles; Bentrem, David; Kim, Hong J; Carr, Jacquelyn; Ahmad, Syed; Abbott, Daniel; Wilson, Gregory C; Kooby, David A; Maithel, Shishir K

    2018-01-01

    Pancreatic mucinous cystic neoplasms (MCNs) are rare tumors typically of the distal pancreas that harbor malignant potential. Although resection is recommended, data are limited on optimal operative approaches to distal pancreatectomy for MCN. MCN resections (2000-2014; eight institutions) were included. Outcomes of minimally invasive and open MCN resections were compared. A total of 289 patients underwent distal pancreatectomy for MCN: 136(47%) minimally invasive and 153(53%) open. Minimally invasive procedures were associated with smaller MCN size (3.9 vs 6.8 cm; P = 0.001), lower operative blood loss (192 vs 392 mL; P = 0.001), and shorter hospital stay(5 vs 7 days; P = 0.001) compared with open. Despite higher American Society of Anesthesiologists class, hand-assisted (n = 46) had similar advantages as laparoscopic/robotic (n = 76). When comparing hand-assisted to open, although MCN size was slightly smaller (4.1 vs 6.8 cm; P = 0.001), specimen length, operative time, and nodal yield were identical. Similar to laparoscopic/robotic, hand-assisted had lower operative blood loss (161 vs 392 mL; P = 0.001) and shorter hospital stay (5 vs 7 days; P = 0.03) compared with open, without increased complications. Hand-assisted laparoscopic technique is a useful approach for MCN resection because specimen length, lymph node yield, operative time, and complication profiles are similar to open procedures, but it still offers the advantages of a minimally invasive approach. Hand-assisted laparoscopy should be considered as an alternative to open technique or as a successive step before converting from total laparoscopic to open distal pancreatectomy for MCN.

  6. Point of care hand hygiene-where's the rub? A survey of US and Canadian health care workers' knowledge, attitudes, and practices.

    PubMed

    Kirk, Jane; Kendall, Anson; Marx, James F; Pincock, Ted; Young, Elizabeth; Hughes, Jillian M; Landers, Timothy

    2016-10-01

    Hand hygiene at the point of care is recognized as a best practice for promoting compliance at the moments when hand hygiene is most critical. The objective of this study was to compare knowledge, attitudes, and practices of US and Canadian frontline health care personnel regarding hand hygiene at the point of care. Physicians and nurses in US and Canadian hospitals were invited to complete a 32-question online survey based on evidence supporting point of care hand hygiene. Eligible health care personnel were in direct clinical practice at least 50% of the time. Three hundred fifty frontline caregivers completed the survey. Among respondents, 57.1% were from the United States and 42.9% were from Canada. Respondents were evenly distributed between physician and nurses. The US and Canadian respondents gave identical ranking to their perceived barriers to hand hygiene compliance. More than half of the respondents from both the United States and Canada agreed or strongly agreed that they would be more likely to clean their hands when recommended if alcohol-based handrub was closer to the patient. This survey demonstrates that similarities between Canada and the United States were more common than not, and the survey raises, or suggests, potential knowledge gaps that require further illumination. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  7. Comparative study of presurgical hand hygiene with hydroalcoholic solution versus traditional presurgical hand hygiene.

    PubMed

    López Martín, M Beatriz; Erice Calvo-Sotelo, Alejo

    To compare presurgical hand hygiene with hydroalcoholic solution following the WHO protocol with traditional presurgical hand hygiene. Cultures of the hands of surgeons and surgical nurses were performed before and after presurgical hand hygiene and after removing gloves at the end of surgery. Cultures were done in 2different days: the first day after traditional presurgical hand hygiene, and the second day after presurgical hand hygiene with hydroalcoholic solution following the WHO protocol. The duration of the traditional hand hygiene was measured and compared with the duration (3min) of the WHO protocol. The cost of the products used in the traditional technique was compared with the cost of the hydroalcoholic solution used. The variability of the traditional technique was determined by observation. Following presurgical hand hygiene with hydroalcoholic solution, colony-forming units (CFU) were detected in 5 (7.3%) subjects, whereas after traditional presurgical hand hygiene CFU were detected in 14 subjects (20.5%) (p < 0.05). After glove removal, the numbers of CFU were similar. The time employed in hand hygiene with hydroalcoholic solution (3min) was inferior to the time employed in the traditional technique (p < 0.05), its cost was less than half, and there was no variability. Compared with other techniques, presurgical hand hygiene with hydroalcoholic solution significantly decreases CFU, has similar latency time, a lower cost, and saves time. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  8. Hand hygiene and healthcare system change within multi-modal promotion: a narrative review.

    PubMed

    Allegranzi, B; Sax, H; Pittet, D

    2013-02-01

    Many factors may influence the level of compliance with hand hygiene recommendations by healthcare workers. Lack of products and facilities as well as their inappropriate and non-ergonomic location represent important barriers. Targeted actions aimed at making hand hygiene practices feasible during healthcare delivery by ensuring that the necessary infrastructure is in place, defined as 'system change', are essential to improve hand hygiene in healthcare. In particular, access to alcohol-based hand rubs (AHRs) enables appropriate and timely hand hygiene performance at the point of care. The feasibility and impact of system change within multi-modal strategies have been demonstrated both at institutional level and on a large scale. The introduction of AHRs overcomes some important barriers to best hand hygiene practices and is associated with higher compliance, especially when integrated within multi-modal strategies. Several studies demonstrated the association between AHR consumption and reduction in healthcare-associated infection, in particular, meticillin-resistant Staphylococcus aureus bacteraemia. Recent reports demonstrate the feasibility and success of system change implementation on a large scale. The World Health Organization and other investigators have reported the challenges and encouraging results of implementing hand hygiene improvement strategies, including AHR introduction, in settings with limited resources. This review summarizes the available evidence demonstrating the need for system change and its importance within multi-modal hand hygiene improvement strategies. This topic is also discussed in a global perspective and highlights some controversial issues. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. Single crystalline growth of a soluble organic semiconductor in a parallel aligned liquid crystal solvent using rubbing-treated polyimide films

    NASA Astrophysics Data System (ADS)

    Matsuzaki, Tomoya; Shibata, Yosei; Takeda, Risa; Ishinabe, Takahiro; Fujikake, Hideo

    2017-01-01

    For directional control of organic single crystals, we propose a crystal growth method using liquid crystal as the solvent. In this study, we examined the formation of 2,7-dioctyl[1]benzothieno[3,2-b][1]benzothiophene (C8-BTBT) single crystals using a parallel aligned liquid crystal (LC) cell and rubbing-treated polyimide films in order to clarify the effects of LC alignment on anisotropic C8-BTBT crystal growth. Based on the results, we found that the crystal growth direction of C8-BTBT single crystals was related to the direction of the aligned LC molecules because of rubbing treatment. Moreover, by optical evaluation, we found that the C8-BTBT single crystals have a aligned molecular structure.

  10. Changing the paradigm: messages for hand hygiene education and audit from cluster analysis.

    PubMed

    Gould, D J; Navaie, D; Purssell, E; Drey, N S; Creedon, S

    2018-04-01

    Hand hygiene is considered to be the foremost infection prevention measure. How healthcare workers accept and make sense of the hand hygiene message is likely to contribute to the success and sustainability of initiatives to improve performance, which is often poor. A survey of nurses in critical care units in three National Health Service trusts in England was undertaken to explore opinions about hand hygiene, use of alcohol hand rubs, audit with performance feedback, and other key hand-hygiene-related issues. Data were analysed descriptively and subjected to cluster analysis. Three main clusters of opinion were visualized, each forming a significant group: positive attitudes, pragmatism and scepticism. A smaller cluster suggested possible guilt about ability to perform hand hygiene. Cluster analysis identified previously unsuspected constellations of beliefs about hand hygiene that offer a plausible explanation for behaviour. Healthcare workers might respond to education and audit differently according to these beliefs. Those holding predominantly positive opinions might comply with hand hygiene policy and perform well as infection prevention link nurses and champions. Those holding pragmatic attitudes are likely to respond favourably to the need for professional behaviour and need to protect themselves from infection. Greater persuasion may be needed to encourage those who are sceptical about the importance of hand hygiene to comply with guidelines. Interventions to increase compliance should be sufficiently broad in scope to tackle different beliefs. Alternatively, cluster analysis of hand hygiene beliefs could be used to identify the most effective educational and monitoring strategies for a particular clinical setting. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  11. Comparison between rinse and crush-and-rub sampling for aerobic bacteria recovery from broiler hatching eggs after sanitization

    USDA-ARS?s Scientific Manuscript database

    This study compared surface and deep eggshell aerobic bacteria recovered by rinse and crush-and-rub sampling methods for commercial hatching eggs after treatment with sanitizers. Eggs were arranged into 5 treatments consisting of No-treatment, Water, and three sanitizers. Sanitizers were Hydrogen ...

  12. Hand Hygiene Improvement and Sustainability: Assessing a Breakthrough Collaborative in Western Switzerland.

    PubMed

    Staines, Anthony; Amherdt, Isabelle; Lécureux, Estelle; Petignat, Christiane; Eggimann, Philippe; Schwab, Marcos; Pittet, Didier

    2017-12-01

    OBJECTIVE To assess hand hygiene improvement and sustainability associated with a Breakthrough Collaborative. DESIGN Multicenter analysis of hand hygiene compliance through direct observation by trained observers. SETTING A total of 5 publicly funded hospitals in 14 locations, with a total of 1,152 beds, in the County of Vaud, Switzerland. PARTICIPANTS Clinical staff. INTERVENTIONS In total, 59,272 opportunities for hand hygiene were monitored for the duration of the study, for an average of 5,921 per audit (range, 5,449-6,852). An 18-month Hand Hygiene Breakthrough Collaborative was conducted to implement the WHO multimodal promotional strategy including improved access to alcohol-based hand rub, education, performance measurement and feedback, reminders and communication, leadership engagement, and safety culture. RESULTS Overall hand hygiene compliance improved from 61.9% to 88.3% (P<.001) over 18 months and was sustained at 88.9% (P=.248) 12 months after the intervention. Hand hygiene compliance among physicians increased from 62% to 85% (P<.001) and finally 86% at follow-up (P=.492); for nursing staff, compliance improved from 64% to 90% (P<.001) and finally 90% at follow-up (P=.464); for physiotherapists compliance improved from 50% to 90% (P<.001) and finally 91% at follow-up (P=.619); for X-ray technicians compliance improved from 45% to 80% (P<.001) and finally 81% at follow-up (P=.686). Hand hygiene compliance also significantly increased with sustained improvement across all hand hygiene indications and all hospitals. CONCLUSIONS A rigorously conducted multicenter project combining the Breakthrough Collaborative method for its structure and the WHO multimodal strategy for content and measurement was associated with significant and substantial improvement in compliance across all professions, all hand hygiene indications, and all participating hospitals. Infect Control Hosp Epidemiol 2017;38:1420-1427.

  13. Ex vivo skin absorption of terpenes from Vicks VapoRub ointment.

    PubMed

    Cal, Krzysztof; Sopala, Monika

    2008-08-01

    The pharmaceutical market offers a wide range of inhalant drug products applied on the skin that contain essential oils and/or their isolated compounds, i.e. terpenes. Because there are few data concerning the skin penetration of terpenes, especially from complex carriers, the goal of this study was to determine the ex vivo skin absorption kinetics of chosen terpenes, namely eucalyptol, menthol, camphor, alpha-pinene, and beta-pinene, from the product Vicks VapoRub. Human cadaver skin was placed in a flow-through diffusion chamber and the product was applied for 15, 30, and 60 min. After the application time the skin was separated into layers using a tape-stripping technique: three fractions of stratum corneum and epidermis with dermis, and terpenes amounts in the samples were determined by gas-chromatography. The investigated terpenes showed different absorption characteristics related to their physicochemical properties and did not permeate through the skin into the acceptor fluid. Eucalyptol had the largest total accumulation in the stratum corneum and in the epidermis with dermis, while alpha-pinene penetrated into the skin in the smallest amount. The short time in which saturation of the stratum corneum with the terpenes occurred and the high accumulation of most of the investigated terpenes in the skin layers proved that these compounds easily penetrate and permeate the stratum corneum and that in vivo they may easily penetrate into the blood circulation.

  14. Establishment of an efficient virus-induced gene silencing (VIGS) assay in Arabidopsis by Agrobacterium-mediated rubbing infection.

    PubMed

    Manhães, Ana Marcia E de A; de Oliveira, Marcos V V; Shan, Libo

    2015-01-01

    Several VIGS protocols have been established for high-throughput functional genomic screens as it bypasses the time-consuming and laborious process of generation of transgenic plants. The silencing efficiency in this approach is largely hindered by a technically demanding step in which the first pair of newly emerged true leaves at the 2-week-old stage are infiltrated with a needleless syringe. To further optimize VIGS efficiency and achieve rapid inoculation for a large-scale functional genomic study, here we describe a protocol of an efficient VIGS assay in Arabidopsis using Agrobacterium-mediated rubbing infection. The Agrobacterium inoculation is performed by simply rubbing the leaves with Filter Agent Celite(®) 545. The highly efficient and uniform silencing effect was indicated by the development of a visibly albino phenotype due to silencing of the Cloroplastos alterados 1 (CLA1) gene in the newly emerged leaves. In addition, the albino phenotype could be observed in stems and flowers, indicating its potential application for gene functional studies in the late vegetative development and flowering stages.

  15. Evaluation of protective gloves and working techniques for reducing hand-arm vibration exposure in the workplace.

    PubMed

    Milosevic, Matija; McConville, Kristiina M Valter

    2012-01-01

    Operation of handheld power tools results in exposure to hand-arm vibrations, which over time lead to numerous health complications. The objective of this study was to evaluate protective equipment and working techniques for the reduction of vibration exposure. Vibration transmissions were recorded during different work techniques: with one- and two-handed grip, while wearing protective gloves (standard, air and anti-vibration gloves) and while holding a foam-covered tool handle. The effect was examined by analyzing the reduction of transmitted vibrations at the wrist. The vibration transmission was recorded with a portable device using a triaxial accelerometer. The results suggest large and significant reductions of vibration with appropriate safety equipment. Reductions of 85.6% were achieved when anti-vibration gloves were used. Our results indicated that transmitted vibrations were affected by several factors and could be measured and significantly reduced.

  16. In-vivo efficacy of hand sanitisers against feline calicivirus: a surrogate for norovirus.

    PubMed

    Lages, S L S; Ramakrishnan, M A; Goyal, S M

    2008-02-01

    Hand disinfection is considered important in preventing the transmission of viruses, including norovirus. We investigated the virucidal efficacy of nine hand sanitisers (four alcohol-based sanitisers, three non-alcoholic sanitisers and two triclosan-containing antimicrobial liquid soaps) against feline calicivirus, a surrogate for norovirus, on artificially contaminated fingertips for 30 s and 2 min contact periods. Among alcohol-based sanitisers, a product containing 99.5% ethanol was more effective than those containing 62% ethanol, 70% isopropanol or 91% isopropanol. A log(10) virus reduction factor of 1.00-1.30 was achieved with 99.5% ethanol but those containing a lower alcohol concentration only achieved a log(10) reduction factor of hands without any soap (a log(10) reduction factor of 0.33-0.42). These results indicate that triclosan-containing antimicrobial soaps or alcohol-based hand rubs may be inadequate for preventing norovirus transmission. Further research on alternative hand sanitisers should continue for effective control of norovirus infections.

  17. Hand hygiene regimens for the reduction of risk in food service environments.

    PubMed

    Edmonds, Sarah L; McCormack, Robert R; Zhou, Sifang Steve; Macinga, David R; Fricker, Christopher M

    2012-07-01

    Pathogenic strains of Escherichia coli and human norovirus are the main etiologic agents of foodborne illness resulting from inadequate hand hygiene practices by food service workers. This study was conducted to evaluate the antibacterial and antiviral efficacy of various hand hygiene product regimens under different soil conditions representative of those in food service settings and assess the impact of product formulation on this efficacy. On hands contaminated with chicken broth containing E. coli, representing a moderate soil load, a regimen combining an antimicrobial hand washing product with a 70% ethanol advanced formula (EtOH AF) gel achieved a 5.22-log reduction, whereas a nonantimicrobial hand washing product alone achieved a 3.10log reduction. When hands were heavily soiled from handling ground beef containing E. coli, a wash-sanitize regimen with a 0.5% chloroxylenol antimicrobial hand washing product and the 70% EtOH AF gel achieved a 4.60-log reduction, whereas a wash-sanitize regimen with a 62% EtOH foam achieved a 4.11-log reduction. Sanitizing with the 70% EtOH AF gel alone was more effective than hand washing with a nonantimicrobial product for reducing murine norovirus (MNV), a surrogate for human norovirus, with 2.60- and 1.79-log reductions, respectively. When combined with hand washing, the 70% EtOH AF gel produced a 3.19-log reduction against MNV. A regimen using the SaniTwice protocol with the 70% EtOH AF gel produced a 4.04-log reduction against MNV. These data suggest that although the process of hand washing helped to remove pathogens from the hands, use of a wash-sanitize regimen was even more effective for reducing organisms. Use of a high-efficacy sanitizer as part of a wash-sanitize regimen further increased the efficacy of the regimen. The use of a well-formulated alcohol-based hand rub as part of a wash-sanitize regimen should be considered as a means to reduce risk of infection transmission in food service facilities.

  18. Combining variational and model-based techniques to register PET and MR images in hand osteoarthritis

    NASA Astrophysics Data System (ADS)

    Magee, Derek; Tanner, Steven F.; Waller, Michael; Tan, Ai Lyn; McGonagle, Dennis; Jeavons, Alan P.

    2010-08-01

    Co-registration of clinical images acquired using different imaging modalities and equipment is finding increasing use in patient studies. Here we present a method for registering high-resolution positron emission tomography (PET) data of the hand acquired using high-density avalanche chambers with magnetic resonance (MR) images of the finger obtained using a 'microscopy coil'. This allows the identification of the anatomical location of the PET radiotracer and thereby locates areas of active bone metabolism/'turnover'. Image fusion involving data acquired from the hand is demanding because rigid-body transformations cannot be employed to accurately register the images. The non-rigid registration technique that has been implemented in this study uses a variational approach to maximize the mutual information between images acquired using these different imaging modalities. A piecewise model of the fingers is employed to ensure that the methodology is robust and that it generates an accurate registration. Evaluation of the accuracy of the technique is tested using both synthetic data and PET and MR images acquired from patients with osteoarthritis. The method outperforms some established non-rigid registration techniques and results in a mean registration error that is less than approximately 1.5 mm in the vicinity of the finger joints.

  19. Hand disinfection in a neonatal intensive care unit: continuous electronic monitoring over a one-year period.

    PubMed

    Helder, Onno K; van Goudoever, Johannes B; Hop, Wim C J; Brug, Johannes; Kornelisse, René F

    2012-10-08

    Good hand hygiene compliance is essential to prevent nosocomial infections in healthcare settings. Direct observation of hand hygiene compliance is the gold standard but is time consuming. An electronic dispenser with built-in wireless recording equipment allows continuous monitoring of its usage. The purpose of this study was to monitor the use of alcohol-based hand rub dispensers with a built-in electronic counter in a neonatal intensive care unit (NICU) setting and to determine compliance with hand hygiene protocols by direct observation. A one-year observational study was conducted at a 27 bed level III NICU at a university hospital. All healthcare workers employed at the NICU participated in the study. The use of bedside dispensers was continuously monitored and compliance with hand hygiene was determined by random direct observations. A total of 258,436 hand disinfection events were recorded; i.e. a median (interquartile range) of 697 (559-840) per day. The median (interquartile range) number of hand disinfection events performed per healthcare worker during the day, evening, and night shifts was 13.5 (10.8 - 16.7), 19.8 (16.3 - 24.1), and 16.6 (14.2 - 19.3), respectively. In 65.8% of the 1,168 observations of patient contacts requiring hand hygiene, healthcare workers fully complied with the protocol. We conclude that the electronic devices provide useful information on frequency, time, and location of its use, and also reveal trends in hand disinfection events over time. Direct observations offer essential data on compliance with the hand hygiene protocol. In future research, data generated by the electronic devices can be supplementary used to evaluate the effectiveness of hand hygiene promotion campaigns.

  20. [Influence of promotional material on hand hygiene in the safety culture of a tertiary hospital].

    PubMed

    Molina-Cabrillana, J; Dorta-Hung, M E; Otero Sanz, L; Henández Vera, J R; Martín-Rodríguez, M M; García de Carlos, P

    2016-06-01

    In order to increase safety culture about hand hygiene by means of messages and reminders about its importance in preventing nosocomial infections, we developed a new set of materials in the Complejo Hospitalario Universitario Insular Materno-Infantil of Las Palmas, Gran Canaria, constitued by two centres with 450 beds each and acredited for medical internal residents training. We hired a well-known caricaturist, who adapted the messages to the local way of speaking, by using characters that used to appear in his artwork in the local newspaper. Also, we continued to work with other graphic design professionals. We monitored adherence and consumption of products for hand rubbing. We noted an increase in both indicators in the following months after the implementation of this strategy. Moreover, we revised the infrastructures for hand hygiene, and were able to demonstrate improvements in most of the patient care areas. The material was well accepted by professionals, patients and visitors. No other interventions were made, so we think improvements can be attributable to this strategy in our setting. Copyright © 2016 SECA. Published by Elsevier Espana. All rights reserved.

  1. Hang Them High: A Hands-Free Technique for Upper Extremity Limb Holding During Surgical Preparation.

    PubMed

    Aneja, Arun; Leung, Patrick; Marquez-Lara, Alejandro

    Lifting and holding upper and lower limbs during the "prep and drape" portion of certain orthopaedic procedures exert strong forces on the holder and may lead to musculoskeletal disorders. To address these challenges during upper extremity procedures, this article describes a hand-free elevation and traction technique of the upper limbs during preoperative skin preparation with the use of items readily available within the operating room (OR). This technique is particularly useful for heavy or fractured limbs that may impose a physical challenge to lift and maintain in a stable position. Implementation of this technique reduces the risk to nurses, OR personnel, and caregivers of developing work-related musculoskeletal injuries while lifting and holding limbs in the orthopaedic OR.

  2. STOPFLU: is it possible to reduce the number of days off in office work by improved hand-hygiene?

    PubMed Central

    2010-01-01

    Background Acute infectious diseases are major causes of short periods of days off from work, day care and school. These diseases are mainly caused by viruses and hands have a key role in their transmission. Thus, hypothetically, they can be controlled with means of intensified hand hygiene. In this study we aim to elucidate the effect of acute infectious diseases on the work contribution in common office work and study the influence of improved hand hygiene on possible reduction of infectious disease episodes and days off from work due to acute infectious diseases. Design The voluntary participants have been recruited from six companies in the Helsinki region. The designated 21 study clusters were identified as operationally distinct working units each containing at least 50 people. The clusters were matched and randomized based on results of a pre-trial contagion risk survey. Improved hand hygiene is being executed with guided hand-washing with soap and water in one intervention arm and with alcohol based hand rubbing disinfectant in the other. Participants in both arms have received guidance on how to avoid infections and how to implement contagion stopping habits. A control arm is acting as before regarding hand hygiene. Data collection for evaluation of the efficacy of the interventions is based on self-reporting through weekly electronic reports. The questionnaire is enquiring about possible respiratory or gastrointestinal symptoms during the preceding week, and requests a daily report of presence of symptoms and working capacity. Etiology of the symptoms is not searched for individually, but contribution of different viruses is evaluated by sentinel surveillance, where occupational health clinics located in the premises of the participating companies collect specimens from employees visiting the clinic. Common causative agents of the diseases are being searched for using real-time PCR techniques. The duration of the intervention will be 16 months. Primary

  3. Effectiveness of liquid soap and hand sanitizer against Norwalk virus on contaminated hands.

    PubMed

    Liu, Pengbo; Yuen, Yvonne; Hsiao, Hui-Mien; Jaykus, Lee-Ann; Moe, Christine

    2010-01-01

    Disinfection is an essential measure for interrupting human norovirus (HuNoV) transmission, but it is difficult to evaluate the efficacy of disinfectants due to the absence of a practicable cell culture system for these viruses. The purpose of this study was to screen sodium hypochlorite and ethanol for efficacy against Norwalk virus (NV) and expand the studies to evaluate the efficacy of antibacterial liquid soap and alcohol-based hand sanitizer for the inactivation of NV on human finger pads. Samples were tested by real-time reverse transcription-quantitative PCR (RT-qPCR) both with and without a prior RNase treatment. In suspension assay, sodium hypochlorite concentrations of >or=160 ppm effectively eliminated RT-qPCR detection signal, while ethanol, regardless of concentration, was relatively ineffective, giving at most a 0.5 log(10) reduction in genomic copies of NV cDNA. Using the American Society for Testing and Materials (ASTM) standard finger pad method and a modification thereof (with rubbing), we observed the greatest reduction in genomic copies of NV cDNA with the antibacterial liquid soap treatment (0.67 to 1.20 log(10) reduction) and water rinse only (0.58 to 1.58 log(10) reduction). The alcohol-based hand sanitizer was relatively ineffective, reducing the genomic copies of NV cDNA by only 0.14 to 0.34 log(10) compared to baseline. Although the concentrations of genomic copies of NV cDNA were consistently lower on finger pad eluates pretreated with RNase compared to those without prior RNase treatment, these differences were not statistically significant. Despite the promise of alcohol-based sanitizers for the control of pathogen transmission, they may be relatively ineffective against the HuNoV, reinforcing the need to develop and evaluate new products against this important group of viruses.

  4. Nanomachining by rubbing at ultrasonic frequency under controlled shear force.

    PubMed

    Muraoka, Mikio

    2011-03-01

    This study proposes a new method of proximal-probe machining that uses a rubbing process by introducing concentrated-mass (CM) cantilevers. At the second resonance of the CM cantilever vibration, the tip site of the cantilever becomes a node of the standing deflection wave because of the sufficient inertia of the attached concentrated mass. The tip makes a cyclic motion that is tangential to the sample surface, not vertical to it, as in a tapping motion. This lateral tip motion that is selectively excited by CM cantilevers was effective for the material modification of a sample due to the friction between the tip and the sample. Imaging and nanomachining under controlled shear force were demonstrated by means of the modified cantilever and a normal atomic force microscope. We were able to write a micron-sized letter "Z" having a line width of 30-100 nm on a resin surface.

  5. Constraint-Induced Therapy Combined with Conventional Neurorehabilitation Techniques in Chronic Stroke Patients with Plegic Hands: A Case Series

    PubMed Central

    Taub, Edward; Uswatte, Gitendra; Bowman, Mary H.; Mark, Victor W.; Delgado, Adriana; Bryson, Camille; Morris, David; Bishop-McKay, Staci

    2012-01-01

    Objective To determine in this pilot study whether the combination of CI therapy and conventional rehabilitation techniques can produce meaningful motor improvement in chronic stroke patients with initially fisted hands. In the past, limited success has been achieved using CI therapy alone for stroke patients with plegic hands. Design Case series Setting University hospital outpatient laboratory Participants Consecutive sample of 6 patients > 1 yr post-stroke with plegic hands Interventions Treatment consisted of an initial period of 3 weeks (Phase A) when adaptive equipment in the home, orthotics and splints were employed to improve ability to engage in activities of daily living. This was continued in Phase B, when CI therapy along with selected neurodevelopmental treatment techniques were added. Main Outcome Measures Motor Activity Log (MAL), accelerometry, Fugl-Meyer Motor Assessment (F-M) Results Patients exhibited a large improvement in spontaneous real-world use of the more-affected arm (mean lower-functioning MAL change = 1.3±0.4 points, P <0.001, d′ = 3.0), and a similar pattern of increase in an objective measure of real-world more-affected arm movement (mean change in ratio of more- to less-affected arm accelerometer recordings = 0.12±0.1 points, P = 0.016 d′ = 1.2). A large improvement in motor status was also recorded (mean F-M change = 5.3±3.3 points, P = 0.005, d′ = 1.6). Conclusions The findings of this pilot study suggest that stroke patients with plegic hands can benefit from CI therapy combined with some conventional rehabilitation techniques, even long after brain injury. More research is warranted. PMID:22922823

  6. The Kinematics of Trunk and Upper Extremities in One-Handed and Two-Handed Backhand Stroke

    PubMed Central

    Stępień, Adam; Bober, Tadeusz; Zawadzki, Jerzy

    2011-01-01

    The aim of this study was to present kinematics of trunk and upper extremities in tennis players who perform one-handed and two-handed backhand strokes. The study aimed to address the question of whether one of those techniques has some important advantage over the other. If so, what makes it superior? The study included 10 tennis coaches with average coaching experience of 9 years. The coaches were asked to hit 15 one-handed and two-handed backhands. The tests were carried out in a laboratory. A sponge ball was used in order to protect the measurement equipment. Video motion analysis was carried out using BTS SMART system; images were recorded with 6 cameras with a rate of 120 frames per second. The analysis of both backhand strokes focused on the second phase of the stroke (acceleration). The use of an eight-element model of human body for description of upper body motion in both techniques revealed kinematic differences in how both backhands are performed. The two-handed backhand was performed in closed kinetic chain with 8 degrees of freedom, whereas the one-handed backhand involved an open kinetic chain with 7 degrees of freedom. Higher rigidity of upper extremities which are connected with trunk in the two-handed backhand, contributes to an elevated trunk effect in this stroke. This is confirmed by higher component velocities for racket handle, which result from trunk rotation in the two-handed backhand and a negative separation angle in the two-handed backhand at the moment of contact of the racket with the ball. The study does not provide a clear-cut answer to the question of advantages of one technique over the other; however, it reveals dissimilar patterns of driving the racket in both techniques, which suggests the need for extending the analysis of techniques of both backhands with additional kinematics of tennis racket in consideration of measurements of ball velocities. PMID:23486650

  7. Impact of a standardized hand hygiene program on the incidence of nosocomial infection in very low birth weight infants.

    PubMed

    Capretti, Maria Grazia; Sandri, Fabrizio; Tridapalli, Elisabetta; Galletti, Silvia; Petracci, Elisabetta; Faldella, Giacomo

    2008-08-01

    This study examined the effects of a standardized hand hygiene program on the rate of nosocomial infection (NI) in very low birth weight (VLBW) infants (birth weight < 1500 g) admitted to our neonatal intensive care unit (NICU). We compared the rate of NI in VLBW infants in 2 separate periods. In the first period, staff were encouraged to perform handwashing using a plain fluid detergent (0.5% triclosan). In the second period, a standardized hand hygiene program was implemented using antimicrobial soap (4% chlorhexidine gluconate) and alcohol-based hand rubs. NI after 72 hours of life was detected in 16 of the 85 VLBW infants in the first period and in 5 of the 80 VLBW infants in the second period. The rate of central venous catheter colonization was significantly lower in the second period (5.8%) than in the first period (16.6%). In our NICU, the incidence of NI in VLBW infants was significantly reduced after the introduction of a standardized handwashing protocol. In our experience, a proper hand hygiene program can save approximately 10 NI episodes/year, at a cost of $10,000 per episode. Therefore, improving hand hygiene practice is a cost-effective program in the NICU.

  8. A comparison of three rotary systems and hand instrumentation technique for the elimination of Enterococcus faecalis from the root canal.

    PubMed

    Gorduysus, Melahat; Nagas, Emre; Torun, Ozgur Yildirim; Gorduysus, Omer

    2011-12-01

    The aim of this study was to compare the in vitro reduction of a bacterial population in a root canal by mechanical instrumentation using three rotary systems and hand instrumentation technique. The root canals contaminated with a suspension of Enterococcus faecalis were instrumented using ProTaper, K3, HeroShaper and K-file hand instrumentation technique. Later the root canals were sampled. After serial dilutions, samples were incubated in culture media for 24 h. Bacterial colonies were counted and the results were given as number of colony-forming units per millilitre. The results showed that all the canal instrumentation systems reduced the number of bacterial cells in the root canals. Statistically, ProTaper instruments were more effective in reducing the number of bacteria than the other rotary files or hand instruments. © 2010 The Authors. Australian Endodontic Journal © 2010 Australian Society of Endodontology.

  9. Effect of hand sanitizer on the performance of fingermark detection techniques.

    PubMed

    Chadwick, Scott; Neskoski, Melissa; Spindler, Xanthe; Lennard, Chris; Roux, Claude

    2017-04-01

    Hand sanitizers have seen a rapid increase in popularity amongst the general population and this increased use has led to the belief that hand sanitizers may have an effect on subsequent fingermark detection. Based on this hypothesis, three alcoholic and two non-alcoholic hand sanitizers were evaluated to determine the effect they had on the detection of fingermarks deposited after their use. The following fingermark detection methods were applied: 1,2-indanedione-zinc, ninhydrin, physical developer (porous substrate); and cyanoacrylate, rhodamine 6G, magnetic powder (non-porous substrate). Comparison between hand sanitized fingermarks and non-hand sanitized fingermarks showed that the alcohol-based hand sanitizers did not result in any visible differences in fingermark quality. The non-alcoholic hand sanitizers, however, improved the quality of fingermarks developed with 1,2-indanedione-zinc and ninhydrin, and marginally improved those developed with magnetic powder. Different parameters, including time since hand sanitizer application prior to fingermark deposition and age of deposited mark, were tested to determine the longevity of increased development quality. The non-alcoholic hand sanitized marks showed no decrease in quality when aged for up to two weeks. The time since sanitizer application was determined to be an important factor that affected the quality of non-alcoholic hand sanitized fingermarks. It was hypothesized that the active ingredient in non-alcoholic hand sanitizers, benzalkonium chloride, is responsible for the increase in fingermark development quality observed with amino acid reagents, while the increased moisture content present on the ridges resulted in better powdered fingermarks. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. A data mining technique for discovering distinct patterns of hand signs: implications in user training and computer interface design.

    PubMed

    Ye, Nong; Li, Xiangyang; Farley, Toni

    2003-01-15

    Hand signs are considered as one of the important ways to enter information into computers for certain tasks. Computers receive sensor data of hand signs for recognition. When using hand signs as computer inputs, we need to (1) train computer users in the sign language so that their hand signs can be easily recognized by computers, and (2) design the computer interface to avoid the use of confusing signs for improving user input performance and user satisfaction. For user training and computer interface design, it is important to have a knowledge of which signs can be easily recognized by computers and which signs are not distinguishable by computers. This paper presents a data mining technique to discover distinct patterns of hand signs from sensor data. Based on these patterns, we derive a group of indistinguishable signs by computers. Such information can in turn assist in user training and computer interface design.

  11. [Moving cupping at Hechelu combined with rubbing method for depression of diabetes mellitus].

    PubMed

    He, Lingna; Du, Ping; Shen, Zhifu; Wang, Xuan

    2016-03-01

    To compare the efficacy between moving cupping at Hechelu combined with rubbing method and western medication for depression of diabetes mellitus (DM). Two hundred and sixteen patients were randomly divided into an observation group and a control group, 108 cases in each group. Patients in the observation group were treated with moving cupping at Hechelu combined with rubbing method, once every: other day; six treatments were considered as one course, and totally two courses were given with an interval of: 4 days between courses. Patients in the control group were treated with oral administration of fluoxetine hydrochloride capsules, once a day for consecutive 4 weeks. The Hamilton depression scale (HAMD), self-rating depression scale (SDS) and TCM symptom score were measured before treatment, after the treatment and in follow-up visit one and a half months after treatment. The fasting blood glucose was tested before and after treatment. The glycosylated hemoglobin (HbA1c) was tested in the follow-up visit. The total effective rate was 90.9% (90/99) in the observation group, which was superior to 73.7% (70/95) in the control group (P < 0.05). After the treatment, HAMD, SDS and TCM symptom scores were all reduced apparently in the observation group and the control group (all P < 0.05). After the treatment and the follow-up visit, the TCM symptom score in the observation group was lower than that in the control group (P < 0.05). The levels of HbA1c and GLU were stable in the observation group, and were decreased compared with those before treatment; but the difference between the, two groups was not significant (P > 0.05). The Hechelu theory-based TCM treatment has better: efficacy for depression of diabetes mellitus than fluoxetine hydrochloride capsule, which has less adverse effects.

  12. Estimating dermal transfer from PCB-contaminated porous surfaces.

    PubMed

    Slayton, T M; Valberg, P A; Wait, A D

    1998-06-01

    Health risks posed by dermal contact with PCB-contaminated porous surfaces have not been directly demonstrated and are difficult to estimate indirectly. Surface contamination by organic compounds is commonly assessed by collecting wipe samples with hexane as the solvent. However, for porous surfaces, hexane wipe characterization is of limited direct use when estimating potential human exposure. Particularly for porous surfaces, the relationship between the amount of organic material collected by hexane and the amount actually picked up by, for example, a person's hand touch is unknown. To better mimic PCB pickup by casual hand contact with contaminated concrete surfaces, we used alternate solvents and wipe application methods that more closely mimic casual dermal contact. Our sampling results were compared to PCB pickup using hexane-wetted wipes and the standard rubbing protocol. Dry and oil-wetted samples, applied without rubbing, picked up less than 1% of the PCBs picked up by the standard hexane procedure; with rubbing, they picked up about 2%. Without rubbing, saline-wetted wipes picked up 2.5%; with rubbing, they picked up about 12%. While the nature of dermal contact with a contaminated surface cannot be perfectly reproduced with a wipe sample, our results with alternate wiping solvents and rubbing methods more closely mimic hand contact than the standard hexane wipe protocol. The relative pickup estimates presented in this paper can be used in conjunction with site-specific PCB hexane wipe results to estimate dermal pickup rates at sites with PCB-contaminated concrete.

  13. Brush seal bristle flexure and hard-rub characteristics

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1993-01-01

    The bristles of a 38.1-mm (1.5-in.) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in.) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in.) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in.) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in.) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping', and hot spots and streaks were found. With a smooth-plug rotor, post-test leakage increased 30 percent over pretest leakage.

  14. Brush seal low surface speed hard-rub characteristics

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1993-01-01

    The bristles of a 38.1-mm (1.5-in.) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in.) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in.) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in.) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in.) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping,' and hot spots and streaks were found. With a smooth-plug rotor, post-test leakage increased 30 percent over pretest leakage.

  15. Brush seal bristle flexure and hard-rub characteristics

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1992-01-01

    The bristles of a 38.1-mm (1.5-in) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping,' and hot spots and streaks were found. With a smooth-plug rotor post-test leakage increased 30 percent over pretest leakage.

  16. Brush seal bristle flexure and hard-rub characteristics

    NASA Astrophysics Data System (ADS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1992-08-01

    The bristles of a 38.1-mm (1.5-in) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping,' and hot spots and streaks were found. With a smooth-plug rotor post-test leakage increased 30 percent over pretest leakage.

  17. Brush seal bristle flexure and hard-rub characteristics

    NASA Astrophysics Data System (ADS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1993-10-01

    The bristles of a 38.1-mm (1.5-in.) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in.) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in.) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in.) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in.) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping', and hot spots and streaks were found. With a smooth-plug rotor, post-test leakage increased 30 percent over pretest leakage.

  18. Brush seal low surface speed hard-rub characteristics

    NASA Astrophysics Data System (ADS)

    Hendricks, Robert C.; Carlile, Julie A.; Liang, Anita D.

    1993-06-01

    The bristles of a 38.1-mm (1.5-in.) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in.) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in.) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in.) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in.) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping,' and hot spots and streaks were found. With a smooth-plug rotor, post-test leakage increased 30 percent over pretest leakage.

  19. OsB 2 and RuB 2, ultra-incompressible, hard materials: First-principles electronic structure calculations

    NASA Astrophysics Data System (ADS)

    Chiodo, S.; Gotsis, H. J.; Russo, N.; Sicilia, E.

    2006-07-01

    Recently it has been reported that osmium diboride has an unusually large bulk modulus combined with high hardness, and consequently is a most interesting candidate as an ultra-incompressible and hard material. The electronic and structural properties of the transition metal diborides OsB 2 and RuB 2 have been calculated within the local density approximation (LDA). It is shown that the high hardness is the result of covalent bonding between transition metal d states and boron p states in the orthorhombic structure.

  20. Apical extrusion of debris and irrigants using two hand and three engine-driven instrumentation techniques.

    PubMed

    Ferraz, C C; Gomes, N V; Gomes, B P; Zaia, A A; Teixeira, F B; Souza-Filho, F J

    2001-07-01

    To evaluate the weight of debris and irrigant volume extruded apically from extracted teeth in vitro after endodontic instrumentation using the balanced force technique, a hybrid hand instrumentation technique, and three engine-driven techniques utilizing nickel-titanium instruments (ProFile .04, Quantec 2000 and Pow-R). Five groups of 20 extracted human teeth with single canals were instrumented using one or other of five techniques: balanced force, hybrid, Quantec 2000, ProFile .04, or Pow-R. Debris extruded from the apical foramen during instrumentation were collected into preweighed 1.5 mL tubes. Following instrumentation, the volume of extruded irrigant fluid was determined by visual comparison to control centrifuge tubes filled with 0.25 mL increments of distilled water. The weight of dry extruded dentine debris was also established. Overall, the engine-driven techniques extruded less debris than the manual ones. However, there was no statistical difference between the balanced force technique and the engine-driven methods. The volume of irrigant extruded through the apex was directly associated with the weight of extruded debris, except within the ProFile group. The hybrid technique was associated with the greatest extrusion of both debris and irrigant. Overall, the engine-driven nickel-titanium systems were associated with less apical extrusion.

  1. Fault detection in rotor bearing systems using time frequency techniques

    NASA Astrophysics Data System (ADS)

    Chandra, N. Harish; Sekhar, A. S.

    2016-05-01

    Faults such as misalignment, rotor cracks and rotor to stator rub can exist collectively in rotor bearing systems. It is an important task for rotor dynamic personnel to monitor and detect faults in rotating machinery. In this paper, the rotor startup vibrations are utilized to solve the fault identification problem using time frequency techniques. Numerical simulations are performed through finite element analysis of the rotor bearing system with individual and collective combinations of faults as mentioned above. Three signal processing tools namely Short Time Fourier Transform (STFT), Continuous Wavelet Transform (CWT) and Hilbert Huang Transform (HHT) are compared to evaluate their detection performance. The effect of addition of Signal to Noise ratio (SNR) on three time frequency techniques is presented. The comparative study is focused towards detecting the least possible level of the fault induced and the computational time consumed. The computation time consumed by HHT is very less when compared to CWT based diagnosis. However, for noisy data CWT is more preferred over HHT. To identify fault characteristics using wavelets a procedure to adjust resolution of the mother wavelet is presented in detail. Experiments are conducted to obtain the run-up data of a rotor bearing setup for diagnosis of shaft misalignment and rotor stator rubbing faults.

  2. Volumetric analysis of hand, reciprocating and rotary instrumentation techniques in primary molars using spiral computed tomography: An in vitro comparative study.

    PubMed

    Jeevanandan, Ganesh; Thomas, Eapen

    2018-01-01

    This present study was conducted to analyze the volumetric change in the root canal space and instrumentation time between hand files, hand files in reciprocating motion, and three rotary files in primary molars. One hundred primary mandibular molars were randomly allotted to one of the five groups. Instrumentation was done using Group I; nickel-titanium (Ni-Ti) hand file, Group II; Ni-Ti hand files in reciprocating motion, Group III; Race rotary files, Group IV; prodesign pediatric rotary files, and Group V; ProTaper rotary files. The mean volumetric changes were assessed using pre- and post-operative spiral computed tomography scans. Instrumentation time was recorded. Statistical analysis to access intergroup comparison for mean canal volume and instrumentation time was done using Bonferroni-adjusted Mann-Whitney test and Mann-Whitney test, respectively. Intergroup comparison of mean canal volume showed statistically significant difference between Groups II versus IV, Groups III versus V, and Groups IV versus V. Intergroup comparison of mean instrumentation time showed statistically significant difference among all the groups except Groups IV versus V. Among the various instrumentation techniques available, rotary instrumentation is the considered to be the better instrumentation technique for canal preparation in primary teeth.

  3. The utility of hand transplantation in hand amputee patients.

    PubMed

    Alolabi, Noor; Chuback, Jennifer; Grad, Sharon; Thoma, Achilles

    2015-01-01

    To measure the desirable health outcome, termed utility, and the expected quality-adjusted life years (QALYs) gained with hand composite tissue allotransplantation (CTA) using hand amputee patients and the general public. Using the standard gamble (SG) and time trade-off (TTO) techniques, utilities were obtained from 30 general public participants and 12 amputee patients. The health utility and net QALYs gained or lost with transplantation were computed. A sensitivity analysis was conducted to account for the effects of lifelong immunosuppression on the life expectancy of transplant recipients. Higher scores represent greater utility. Hand amputation mean health utility as measured by the SG and TTO methods, respectively, was 0.72 and 0.80 for the general public and 0.69 and 0.70 for hand amputees. In comparison, hand CTA mean health utility was 0.74 and 0.82 for the general public and 0.83 and 0.86 for amputees. Hand CTA imparted an expected gain of 0.9 QALYs (SG and TTO) in the general public and 7.0 (TTO) and 7.8 (SG) QALYs in hand amputees. A loss of at least 1.7 QALYs was demonstrated when decreasing the life expectancy in the sensitivity analysis in the hand amputee group. Hand amputee patients did not show a preference toward hand CTA with its inherent risks. With this procedure being increasingly adopted worldwide, the benefits must be carefully weighed against the risks of lifelong immunosuppressive therapy. This study does not show clear benefit to advocate hand CTA. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. Evolution of one-handed piano compositions.

    PubMed

    Drozdov, Ignat; Kidd, Mark; Modlin, Irvin M

    2008-01-01

    Electronic searches were performed to investigate the evolution of one-handed piano compositions and one-handed music techniques, and to identify individuals responsible for the development of music meant for playing with one hand. Particularly, composers such as Liszt, Ravel, Scriabin, and Prokofiev established a new model in music by writing works to meet the demands of a variety of pianist-amputees that included Count Géza Zichy (1849-1924), Paul Wittgenstein (1887-1961), and Siegfried Rapp (b. 1915). Zichy was the first to amplify the scope of the repertoire to improve the variety of one-handed music; Wittgenstein developed and adapted specific and novel performance techniques to accommodate one-handedness; and Rapp sought to promote the stature of one-handed pianists among a musically sophisticated public able to appreciate the nuances of such maestros.

  5. [Consumption of hand-hygiene products in health establishments in the west of France].

    PubMed

    Branger, B; Senechal, H; Bataillon, S; Ertzscheid, M A; Baron, R; Borgey, F; Thibon, P; Van Der Mee, N; Girard, N; Wiesel, M; Avril, C; Coulomb, F; Chaperon, J; Lejeune, B

    2005-06-01

    The study had for aim to investigate hand hygiene product use in French hospitals between 2000 and 2003. A questionnaire was sent in 2002 and 2 more in 2003 and 2004 (for 2000 to 2003) requiring data on type of hospital, number of beds, staff members, admissions and patient-day, litres of mild soap, antiseptic soap and alcohol-based rub used and price per litre. Indices were calculated accordingly. 574 hospitals answered over the 4 year period (average 143 per year) representing an average of 50 000 beds/year, 80 000 full-time staff positions, 1.2 million admissions and 16 millions patient-days. The median consumption of mild soap was 3.8 l per bed, 2.7 l per staff member, 2.4 l per 100 admissions, and 10.6 ml per patient-day. The median consumption of antiseptic soap was 1 l per bed, 0.8 l per staff member, 4.8 l per 100 admissions, and 3.2 ml per patient-day. The median consumption of alcohol-based rub (HAS) was 0.3 l per bed, 0.3 l per staff-member, 1.5 l per admission, and 0.9 l per patient-day. Between 2000 and 2003, HAS use significantly increased from 69 to 88% (a relative increase of 31%) and the median consumption increased from 0.5 ml to 1.5 ml per patient-day. 370 fully completed grids gave a number of 7 opportunities per patient-day with less than 1 for HAS. The best indicator for an infection control practitioners is the quantity of alcohol-based solution in ml/patient-day and HAS per patient-day is the reference.

  6. Quantification of the Hawthorne effect in hand hygiene compliance monitoring using an electronic monitoring system: a retrospective cohort study

    PubMed Central

    Srigley, Jocelyn A; Furness, Colin D; Baker, G Ross; Gardam, Michael

    2014-01-01

    Background The Hawthorne effect, or behaviour change due to awareness of being observed, is assumed to inflate hand hygiene compliance rates as measured by direct observation but there are limited data to support this. Objective To determine whether the presence of hand hygiene auditors was associated with an increase in hand hygiene events as measured by a real-time location system (RTLS). Methods The RTLS recorded all uses of alcohol-based hand rub and soap for 8 months in two units in an academic acute care hospital. The RTLS also tracked the movement of hospital hand hygiene auditors. Rates of hand hygiene events per dispenser per hour as measured by the RTLS were compared for dispensers within sight of auditors and those not exposed to auditors. Results The hand hygiene event rate in dispensers visible to auditors (3.75/dispenser/h) was significantly higher than in dispensers not visible to the auditors at the same time (1.48; p=0.001) and in the same dispensers during the week prior (1.07; p<0.001). The rate increased significantly when auditors were present compared with 1–5 min prior to the auditors’ arrival (1.50; p=0.009). There were no significant changes inside patient rooms. Conclusions Hand hygiene event rates were approximately threefold higher in hallways within eyesight of an auditor compared with when no auditor was visible and the increase occurred after the auditors’ arrival. This is consistent with the existence of a Hawthorne effect localised to areas where the auditor is visible and calls into question the accuracy of publicly reported hospital hand hygiene compliance rates. PMID:25002555

  7. The effect of the color red on consuming food does not depend on achromatic (Michelson) contrast and extends to rubbing cream on the skin.

    PubMed

    Bruno, Nicola; Martani, Margherita; Corsini, Claudia; Oleari, Claudio

    2013-12-01

    Recent literature suggests that individuals may consume less food when this is served on red plates. We explored this intriguing effect in three experiments. Independent groups of participants were presented with constant amounts of popcorns, chocolate chips, or moisturizing cream, on red, blue, or white plates. They were asked to sample the foods (by tasting them) or the cream (by rubbing it on the hand and forearm) as they wished and to complete mock "sensory analysis" questionnaires. Results confirmed that red plates reduce taste-related consumption and extended this effect to the touch-related consumption of moisturizing cream. Suggesting that the effect was not due to a decrease in the consciously experienced appeal of products on red plates, overall appreciation of the foods or cream did not differ according to plate color. After careful photometric measures of the materials used for each food-plate pairing, we determined that food and cream consumption was not predicted by Michelson (achromatic) contrast. Although the origin of the intriguing effect of the color red on consumption remains unclear, our results may prove useful to future potential explanations. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Antimicrobial efficacy of soap and water hand washing versus an alcohol-based hand cleanser.

    PubMed

    Holton, Ronald H; Huber, Michaell A; Terezhalmy, Geza T

    2009-12-01

    The emergence of alcohol-based hand cleansers may represent an alternative to soap and water in the clinical dental setting. In this study, the antimicrobial efficacy of traditional hand washing vs. a unique alcohol-based hand cleanser with persistence was evaluated. Two experienced dentists participated over a 10-day period. On days 1-5, each clinician used an antibacterial liquid soap (Dial, Dial Corporation, Scottsdale, AZ). Days 6-10, an alcohol-based hand cleanser (Triseptin Water Optional, Healthpoint Surgical, Fort Worth, TX) was used. Sampling was by modified glove juice technique. The results indicate that the alcohol-based hand cleanser dramatically outperforms the traditional hand washing agent in the general dental setting.

  9. Fat suppression at 2D MR imaging of the hands: Dixon method versus CHESS technique and STIR sequence.

    PubMed

    Kirchgesner, Thomas; Perlepe, Vasiliki; Michoux, Nicolas; Larbi, Ahmed; Vande Berg, Bruno

    2017-04-01

    To compare the effectiveness of fat suppression and the signal-to-noise ratio (SNR) of the Dixon method with those of the CHESS (Chemical Shift-Selective) technique and STIR (Short Tau Inversion Recovery) sequence in hands of normal subjects at 2D MR imaging. 14 healthy volunteers (mean age of 29.4 years) consented to have both hands prospectively imaged with SE T1 Dixon, T1 CHESS, T2 Dixon, T2 CHESS and STIR sequences in a 1.5T MR scanner. Three radiologists scored the effectiveness of fat suppression in bone marrow (EFS BM ) and soft tissues (EFS ST ) in 20 joints per subject. One radiologist measured the SNR in 10 bones per subject. Statistical analysis used two-way ANOVA with random effects, paired t-test and observed agreement to assess differences in effectiveness of fat suppression, differences in SNR and inter-observer agreement. EFS BM was statistically significantly higher for T1 Dixon than for T1 CHESS and for T2 Dixon than for T2 CHESS (p<0.0001). EFS BM was significantly higher for T2 Dixon than for STIR in the coronal plane (p=0.0020). The SNR was significantly higher for T1 Dixon than for T1 CHESS and for T2 Dixon than for STIR (p<0.0001). The SNR was significantly lower for T2 Dixon than for T2 CHESS (p<0.0001). The Dixon method yields more effective fat suppression and higher SNR than the CHESS technique at 2D T1-weighted MR imaging of the hands. At T2-weighted MR imaging, fat suppression is more effective with the Dixon method while SNR is higher with the CHESS technique. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Quantification of the Hawthorne effect in hand hygiene compliance monitoring using an electronic monitoring system: a retrospective cohort study.

    PubMed

    Srigley, Jocelyn A; Furness, Colin D; Baker, G Ross; Gardam, Michael

    2014-12-01

    The Hawthorne effect, or behaviour change due to awareness of being observed, is assumed to inflate hand hygiene compliance rates as measured by direct observation but there are limited data to support this. To determine whether the presence of hand hygiene auditors was associated with an increase in hand hygiene events as measured by a real-time location system (RTLS). The RTLS recorded all uses of alcohol-based hand rub and soap for 8 months in two units in an academic acute care hospital. The RTLS also tracked the movement of hospital hand hygiene auditors. Rates of hand hygiene events per dispenser per hour as measured by the RTLS were compared for dispensers within sight of auditors and those not exposed to auditors. The hand hygiene event rate in dispensers visible to auditors (3.75/dispenser/h) was significantly higher than in dispensers not visible to the auditors at the same time (1.48; p=0.001) and in the same dispensers during the week prior (1.07; p<0.001). The rate increased significantly when auditors were present compared with 1-5 min prior to the auditors' arrival (1.50; p=0.009). There were no significant changes inside patient rooms. Hand hygiene event rates were approximately threefold higher in hallways within eyesight of an auditor compared with when no auditor was visible and the increase occurred after the auditors' arrival. This is consistent with the existence of a Hawthorne effect localised to areas where the auditor is visible and calls into question the accuracy of publicly reported hospital hand hygiene compliance rates. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Incorporation of Hands-On Sterile Technique Instruction in an Introductory Pharmacy Practice Experience

    PubMed Central

    Cruthirds, Danielle; Coward, Lori

    2015-01-01

    Objective. To examine sterile technique and basic sterile compounding procedures among third-year pharmacy students. Design. Third year pharmacy students participating in an introductory pharmacy practice experience (IPPE) in 2012 (n=126) and 2013 (n=119) performed a modified low-risk compounded sterile product (CSP) media fill challenge test, then prepared a 5 mg/mL vancomycin solution that was subsequently analyzed for accuracy. Assessment. To identify deficiencies in sterile procedures, students were observed while performing a modified low-risk CSP media fill challenge test. In the first year of conducting the challenge test (2012), 3 deficiencies were identified: hand washing before compounding, cleaning items with alcohol prior to start, and cleaning work area upon completion. In 2013, significant improvements were observed in these 3 areas after students watched a demonstration video. Examination of CSPs revealed less than 1% contamination in both years. Analysis of compounded vancomycin solutions showed that 84% and 71% of students prepared solutions in 2012 and 2013, respectively, were within 10% of the targeted final concentration. Conclusion. Hands-on sterile compounding exercises are typically delivered early in the pharmacy professional curriculum with minimal reinforcement in subsequent years. Providing opportunities for advanced pharmacy students to refresh and practice sterile compounding procedures allows students to refine their skills before entering pharmacy practice. PMID:25861109

  12. Techniques for small-bone lengthening in congenital anomalies of the hand and foot.

    PubMed

    Minguella, J; Cabrera, M; Escolá, J

    2001-10-01

    The purpose of this study is to analyse three different lengthening techniques used in 31 small bones for congenital malformations of the hand and foot: 15 metacarpals, 12 metatarsals, 1 foot stump and 3 spaces between a previously transplanted phalanx end of the carpus or the metacarpal. Progressive lengthening with an external fixator device was performed in 23 cases: the callus distraction (callotasis) technique was used in 15 cases, whereas in the other 8 cases the speed of lengthening was faster and the defect bridged with a bone graft as a second stage. In another eight cases, a one-stage lengthening was performed. In the callotasis group, the total length gained ranged from 9 mm to 30 mm and the percentage of lengthening obtained (compared with the initial bone length) averaged 53.4%; in the fast lengthening group, the length gained ranged from 8 mm to 15 mm, and the average percentage of lengthening was 53.1%; and in the one-stage group, the length gained ranged from 7 mm to 15 mm, and the average percentage of lengthening was 43%. The overall complication rate was 22.5%.

  13. Using the six sigma process to implement the Centers for Disease Control and Prevention Guideline for Hand Hygiene in 4 intensive care units.

    PubMed

    Eldridge, Noel E; Woods, Susan S; Bonello, Robert S; Clutter, Kay; Ellingson, Leann; Harris, Mary Ann; Livingston, Barbara K; Bagian, James P; Danko, Linda H; Dunn, Edward J; Parlier, Renee L; Pederson, Cheryl; Reichling, Kim J; Roselle, Gary A; Wright, Steven M

    2006-02-01

    The Centers for Disease Control and Prevention (CDC) Guideline for Hand Hygiene in Health Care Settings was issued in 2002. In 2003, the Joint Commission on Accreditation of Healthcare Organizations (JCAHO) established complying with the CDC Guideline as a National Patient Safety Goal for 2004. This goal has been maintained through 2006. The CDC's emphasis on the use of alcohol-based hand rubs (ABHRs) rather than soap and water was an opportunity to improve compliance, but the Guideline contained over 40 specific recommendations to implement. To use the Six Sigma process to examine hand hygiene practices and increase compliance with the CDC hand hygiene recommendations required by JCAHO. Six Sigma Project with pre-post design. Physicians, nurses, and other staff working in 4 intensive care units at 3 hospitals. Observed compliance with 10 required hand hygiene practices, mass of ABHR used per month per 100 patient-days, and staff attitudes and perceptions regarding hand hygiene reported by questionnaire. Observed compliance increased from 47% to 80%, based on over 4,000 total observations. The mass of ABHR used per 100 patient-days in 3 intensive care units (ICUs) increased by 97%, 94%, and 70%; increases were sustained for 9 months. Self-reported compliance using the questionnaire did not change. Staff reported increased use of ABHR and increased satisfaction with hand hygiene practices and products. The Six Sigma process was effective for organizing the knowledge, opinions, and actions of a group of professionals to implement the CDC's evidence-based hand hygiene practices in 4 ICUs. Several tools were developed for widespread use.

  14. Treatment of hand ischemia following angioaccess surgery using the distal revascularization interval-ligation technique with preservation of vascular access: description of an 18-case series.

    PubMed

    Sessa, Carmine; Riehl, Gregory; Porcu, Paolo; Pichot, Olivier; Palacin, Pedro; Maghlaoua, Mohamed; Magne, Jean-Luc

    2004-11-01

    Hand ischemia is a rare complication of angioaccess surgery for hemodialysis. Management usually requires ligation of the arteriovenous fistula (AVF). The purpose of this report is to describe our experience with the use of the distal revascularization interval-ligation (DRIL) technique for treatment of ischemia without ligation of the AVF. From January 1999 to September 2002, the DRIL technique was used to treat 18 patients (10 men, 8 women, 10 diabetic patients) with severe paresthesia of the hand (n = 9) and finger necrosis (n = 10). The AVF was located at the elbow in 16 patients and at the wrist in 2 patients. Mean flow distal to the AVF was less than 10 mL in 5 patients, less than 5 mL in 10, and unmeasurable in 3. The conduit used for all DRIL arterial bypasses, including 15 brachiobrachial bypasses, 1 axillobrachial bypass, 1 brachioradial bypass, and 1 radioradial bypass, was the great saphenous vein graft. Trophic manifestations required finger amputation in five patients, pulpar necrosis resection in four, and transmetacarpal amputation of the index finger in one patient. Symptoms disappeared in 13 patients (73%) and improved in 5 (27%). The time required for healing of finger amputations and trophic manifestations ranged from 15 days to 2 months. Mean arterial flow through the DRIL bypass was 50 mL/min (range, 20-90 mL/min). With a mean follow-up interval of 16 months (range, 5-48 months), primary patency of the DRIL artery bypass and AVF was 94% and the limb salvage rate was 100%. The DRIL technique is the most effective procedure for treatment of angioaccess-induced hand ischemia. This technique can be used to achieve persistent relief of symptoms with continued access patency. The DRIL artery bypass improves vacularization of the hand, and ligature of the artery stops the vascular steal without affecting hemodialysis access. The DRIL technique should be proposed as first-line treatment for hand ischemia due to AVF for hemodialysis.

  15. Towards NIRS-based hand movement recognition.

    PubMed

    Paleari, Marco; Luciani, Riccardo; Ariano, Paolo

    2017-07-01

    This work reports on preliminary results about on hand movement recognition with Near InfraRed Spectroscopy (NIRS) and surface ElectroMyoGraphy (sEMG). Either basing on physical contact (touchscreens, data-gloves, etc.), vision techniques (Microsoft Kinect, Sony PlayStation Move, etc.), or other modalities, hand movement recognition is a pervasive function in today environment and it is at the base of many gaming, social, and medical applications. Albeit, in recent years, the use of muscle information extracted by sEMG has spread out from the medical applications to contaminate the consumer world, this technique still falls short when dealing with movements of the hand. We tested NIRS as a technique to get another point of view on the muscle phenomena and proved that, within a specific movements selection, NIRS can be used to recognize movements and return information regarding muscles at different depths. Furthermore, we propose here three different multimodal movement recognition approaches and compare their performances.

  16. Toe-to-hand transfer: Evolving Indications and Relevant Outcomes

    PubMed Central

    Waljee, Jennifer F.; Chung, Kevin C.

    2014-01-01

    In the late 19th century, the first toe to hand transfer was performed in Vienna, Switzerland as a staged procedure by Nicolandi.(1) Since that time, the advent of microsurgery has revolutionized toe to hand transfers. In 1966, Buncke performed the first microvascular toe to thumb transfer in a rhesus monkey.(2) The first toe to thumb transfer using microsurgical techniques in humans was performed by Cobbett in 1969, followed shortly thereafter by the first transfer of a second toe to the thumb position.(3,4) Today, due to expanding microsurgical techniques and surgeon innovation, the indications and techniques for toe-to-hand transfer procedures continue to evolve and now encompass patients with a variety of acquired and congenital hand defects.(5) PMID:23790426

  17. Reconnaissance investigation of brine in the eastern Rub al Khali, Kingdom of Saudi Arabia

    USGS Publications Warehouse

    Smith, C.L.

    1981-01-01

    Al Uruq al Mu'taridah-Umm as Samim area is located in a large topographic depression in the eastern Rub al Khali desert where playas several thousand square kilometers in area are exposedo A crust of eolian sand cemented with gypsum and halite has formed on many playa surfaces. Anhydrite nodules are common in the sampled area, where the depth to ground water generally exceeds 172 Cmo The chemistry of the three ground-water samples collected near the water well Ramallah-1 (lat 22?10'20'' N., long 54?20'37'' E.) is similar to that of sabkhah-related brines on the coast of the United Arab Emirates. Although there is no indication of economic quantities of evaporite minerals in the sampled area, the extent of the depression and its unique geologic environment recommend it for resource-evaluation studies.

  18. Does intraoperative navigation improve the accuracy of mandibular angle osteotomy: Comparison between augmented reality navigation, individualised templates and free-hand techniques.

    PubMed

    Zhu, Ming; Liu, Fei; Zhou, Chaozheng; Lin, Li; Zhang, Yan; Chai, Gang; Xie, Le; Qi, Fazhi; Li, Qingfeng

    2018-04-11

    Augmented reality (AR)-based navigation surgery has evolved to be an advanced assisted technology. The aim of this study is to manifest the accuracy of AR navigation for the intraoperative mandibular angle osteotomy by comparing the navigation with other interventional techniques. A retrospective study was conducted with 93 post-surgical patients with mandibular angle hypertrophy admitted at our plastic and reconstructive surgery department between September 2011 and June 2016. Thirty-one patients received osteotomy conducted using a navigation system based on augmented reality (AR group), 28 patients received osteotomy conducted using individualised templates (IT group) and the remaining 34 patients received osteotomy performed by free hand (free-hand group). The post-operative computed tomography (CT) images were reviewed and analysed by comparing with pre-surgical planning generated by three-dimensional (3D) software. The preparation time, cutting time, whole operating time and discrepancy in osteotomy lines were measured. The preparation time was much shorter for the free-hand group than that for the AR group and the IT group (P < 0.01). However, no significant difference in the whole operating time was observed among the three groups (P > 0.05). In addition, the discrepancy in osteotomy lines was lower for the AR group and in the IT group than for the free-hand group (P < 0.01). The navigation system based on AR has a higher accuracy, more reliability and better user friendliness for some particular clinical procedures than for other techniques, which has a promising clinical prospect. Copyright © 2018. Published by Elsevier Ltd.

  19. "First-person view" of pathogen transmission and hand hygiene - use of a new head-mounted video capture and coding tool.

    PubMed

    Clack, Lauren; Scotoni, Manuela; Wolfensberger, Aline; Sax, Hugo

    2017-01-01

    Healthcare workers' hands are the foremost means of pathogen transmission in healthcare, but detailed hand trajectories have been insufficiently researched so far. We developed and applied a new method to systematically document hand-to-surface exposures (HSE) to delineate true hand transmission pathways in real-life healthcare settings. A head-mounted camera and commercial coding software were used to capture ten active care episodes by eight nurses and two physicians and code HSE type and duration using a hierarchical coding scheme. We identified HSE sequences of particular relevance to infectious risks for patients based on the WHO 'Five Moments for Hand Hygiene'. The study took place in a trauma intensive care unit in a 900-bed university hospital in Switzerland. Overall, the ten videos totaled 296.5 min and featured eight nurses and two physicians. A total of 4222 HSE were identified (1 HSE every 4.2 s), which concerned bare (79%) and gloved (21%) hands. The HSE inside the patient zone ( n  = 1775; 42%) included mobile objects (33%), immobile surfaces (5%), and patient intact skin (4%), while HSE outside the patient zone ( n  = 1953; 46%) included HCW's own body (10%), mobile objects (28%), and immobile surfaces (8%). A further 494 (12%) events involved patient critical sites. Sequential analysis revealed 291 HSE transitions from outside to inside patient zone, i.e. "colonization events", and 217 from any surface to critical sites, i.e. "infection events". Hand hygiene occurred 97 times, 14 (5% adherence) times at colonization events and three (1% adherence) times at infection events. On average, hand rubbing lasted 13 ± 9 s. The abundance of HSE underscores the central role of hands in the spread of potential pathogens while hand hygiene occurred rarely at potential colonization and infection events. Our approach produced a valid video and coding instrument for in-depth analysis of hand trajectories during active patient care that may help to design

  20. Using the Six Sigma Process to Implement the Centers for Disease Control and Prevention Guideline for Hand Hygiene in 4 Intensive Care Units

    PubMed Central

    Eldridge, Noel E; Woods, Susan S; Bonello, Robert S; Clutter, Kay; Ellingson, LeAnn; Harris, Mary Ann; Livingston, Barbara K; Bagian, James P; Danko, Linda H; Dunn, Edward J; Parlier, Renee L; Pederson, Cheryl; Reichling, Kim J; Roselle, Gary A; Wright, Steven M

    2006-01-01

    BACKGROUND The Centers for Disease Control and Prevention (CDC) Guideline for Hand Hygiene in Health Care Settings was issued in 2002. In 2003, the Joint Commission on Accreditation of Healthcare Organizations (JCAHO) established complying with the CDC Guideline as a National Patient Safety Goal for 2004. This goal has been maintained through 2006. The CDC's emphasis on the use of alcohol-based hand rubs (ABHRs) rather than soap and water was an opportunity to improve compliance, but the Guideline contained over 40 specific recommendations to implement. OBJECTIVE To use the Six Sigma process to examine hand hygiene practices and increase compliance with the CDC hand hygiene recommendations required by JCAHO. DESIGN Six Sigma Project with pre-post design. PARTICIPANTS Physicians, nurses, and other staff working in 4 intensive care units at 3 hospitals. MEASUREMENTS Observed compliance with 10 required hand hygiene practices, mass of ABHR used per month per 100 patient-days, and staff attitudes and perceptions regarding hand hygiene reported by questionnaire. RESULTS Observed compliance increased from 47% to 80%, based on over 4,000 total observations. The mass of ABHR used per 100 patient-days in 3 intensive care units (ICUs) increased by 97%, 94%, and 70%; increases were sustained for 9 months. Self-reported compliance using the questionnaire did not change. Staff reported increased use of ABHR and increased satisfaction with hand hygiene practices and products. CONCLUSIONS The Six Sigma process was effective for organizing the knowledge, opinions, and actions of a group of professionals to implement the CDC's evidence-based hand hygiene practices in 4 ICUs. Several tools were developed for widespread use. PMID:16637959

  1. Energy expenditure for massage therapists during performing selected classical massage techniques.

    PubMed

    Więcek, Magdalena; Szymura, Jadwiga; Maciejczyk, Marcin; Szyguła, Zbigniew; Cempla, Jerzy; Borkowski, Mateusz

    2018-04-11

    The aim of the study is to evaluate the intensity of the effort and energy expenditure in the course of performing selected classical massage techniques and to assess the workload of a massage therapist during a work shift. Thirteen massage therapists (age: 21.9±1.9 years old, body mass index: 24.5±2.8 kg×m-2, maximal oxygen consumption × body mass-1 (VO2 max×BM-1): 42.3±7 ml×kg-1×min-1) were involved in the study. The stress test consisted in performing selected classical massage techniques in the following order: stroking, kneading, shaking, beating, rubbing and direct vibration, during which the cardio-respiratory responses and the subjective rating of perceived exertion (RPE) were assessed. Intensity of exercise during each massage technique was expressed as % VO2 max, % maximal heart rate (HRmax) and % heart rate reserve (HRR). During each massage technique, net energy expenditure (EE) and energy cost of work using metabolic equivalent of task (MET) were determined. The intensity of exercise was 47.2±6.2% as expressed in terms of % VO2 max, and 74.7±3.2% as expressed in terms of % HRmax, while it was 47.8±1.7% on average when expressed in terms of % HRR during the whole procedure. While performing the classical massage, the average EE and MET were 5.6±0.9 kcal×min-1 and 5.6±0.2, respectively. The average RPE calculated for the entire procedure was 12.1±1.4. During the performance of a classical massage technique for a single treatment during the study, the average total EE was 176.5±29.6 kcal, resulting in an energy expenditure of 336.2±56.4 kcal×h-1. In the case of the classical massage technique, rubbing was the highest intensity exercise for the masseur who performed the massage (%VO2 max = 57.4±13.1%, HRmax = 79.6±7.7%, HRR = 58.5±13.1%, MET = 6.7±1.1, EE = 7.1±1.4 kcal×min-1

  2. Preoperative Disinfection of Surgeons' Hands: Use of Alcoholic Solutions and Effects of Gloves on Skin Flora

    PubMed Central

    Lowbury, E. J. L.; Lilly, H. A.; Ayliffe, G. A. J.

    1974-01-01

    A single application of about 10 ml of 95% alcoholic chlorhexidine (0·5%) or tetrabrom-o-methyl phenol (0·1%) rubbed on to the hands until they were dry led to mean reduction in viable bacterial counts from standard handwashings of 97·9 ± 1·09% and 91·8 ± 4·63% respectively. After six of such treatments, three on each of two successive days, the mean reductions in relation to viable counts before the first treatment were 99·7 ± 0·09% for alcoholic chlorhexidine and 99·5 ± 0·17% for tetrabrom-o-methyl phenol. These reductions were greater than those obtained with 4% chlorhexidine detergent solution— 87·1 ± 3·5% and 98·2 ± 1·6%, and with 95% or 70% ethyl alcohol and with aqueous 0·5% chlorhexidine. Preoperative washing of the surgeon's hands with alcoholic chlorhexidine used without addition of water is more effective and less expensive than handwashing with antiseptic detergent preparations and running water. The viable counts of washings from hands treated with various antiseptics, including ethyl alcohol, were lower in relation to the pretreatment levels when gloves had been worn for three hours than when samples for counts were taken immediately after the antiseptic treatment. No such difference was found in samplings from hands washed with unmedicated soap. Tests for residual action of antiseptics on the skin showed a greater effect with alcoholic chlorhexidine than with tetrabrom-o-methyl phenol, though both showed greater residual activity than an Irgasan DP 300 detergent preparation. No residual action was shown after 70% ethyl alcohol. PMID:4609555

  3. Using Goal Setting, Task Clarification, and Feedback to Increase the Use of the Hands-Free Technique by Hospital Operating Room Staff

    ERIC Educational Resources Information Center

    Cunningham, Thomas R.; Austin, John

    2007-01-01

    We evaluated the effects of a behavioral treatment on the safe passing of sharp instruments using the hands-free technique among hospital operating room personnel during surgical procedures. Treatment consisted of participative goal setting, task clarification, and feedback. The average percentage of sharp instruments passed safely increased from…

  4. Occupational Safety. Hand Tools. Pre-Apprenticeship Phase 1 Training.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This self-paced student training module on safety when using hand tools is one of a number of modules developed for Pre-apprenticeship Phase 1 Training. Purpose of the module is to teach students the correct safety techniques for operating common hand- and arm-powered tools, including selection, maintenance, technique, and uses. The module may…

  5. Twisted nematic liquid crystal cells with rubbed poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) films for active polarization control of terahertz waves

    NASA Astrophysics Data System (ADS)

    Sasaki, Tomoyuki; Okuyama, Hiroki; Sakamoto, Moritsugu; Noda, Kohei; Okamoto, Hiroyuki; Kawatsuki, Nobuhiro; Ono, Hiroshi

    2017-04-01

    We fabricated a terahertz (THz) polarization converter using a twisted nematic (TN) liquid crystal (LC) cell. Poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) (PEDOT/PSS) films coated on quartz glass substrates were used as electrode layers in the TN LC cell. The PEDOT/PSS films were rubbed unidirectionally using a rayon cloth to align the nematic LC, thereby also serving as an alignment layer. The azimuthal surface anchoring strength of the PEDOT/PSS films was measured to be 5 × 10-4 J/m2 using the Néel wall method, which is similar to that of typical polymeric alignment layers. The optical constants of the PEDOT/PSS film in the THz range were also characterized using the Drude-Smith model, and the results indicated that the PEDOT/PSS films could be used both as transparent electrodes in the THz range and as alignment layers for the LC. The electro-optical properties of the fabricated TN LC cell were also investigated using a polarized visible laser and THz time-domain spectroscopic system. In particular, the transmission spectra and polarization conversion property of the TN LC cell in the THz range were theoretically analyzed based on a stratified model that considers optical anisotropy, absorption, and multiple interference. This work substantiates the advantages of TN LC cells with rubbed PEDOT/PSS films useful for THz polarization converters with electrical tunability.

  6. Lifelong Learning for the Hand Surgeon.

    PubMed

    Adkinson, Joshua M; Chung, Kevin C

    2015-09-01

    Hand surgeons are faced with the impossible task of mastering a rapidly expanding pool of knowledge and surgical techniques. Dedication to lifelong learning is, therefore, an essential component of delivering the best, most up-to-date care for patients. Board certification, participation in continuing medical education and maintenance of certification activities, and attendance at national meetings are essential mechanisms by which hand surgeons may foster the acquisition of essential knowledge and clinical skills, This article highlights the history, current status, and emerging needs in continuing medical education for the hand surgeon. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  7. Hands-On Calculus

    ERIC Educational Resources Information Center

    Sutherland, Melissa

    2006-01-01

    In this paper we discuss manipulatives and hands-on investigations for Calculus involving volume, arc length, and surface area to motivate and develop formulae which can then be verified using techniques of integration. Pre-service teachers in calculus courses using these activities experience a classroom in which active learning is encouraged and…

  8. Mechanical design of a shape memory alloy actuated prosthetic hand.

    PubMed

    De Laurentis, Kathryn J; Mavroidis, Constantinos

    2002-01-01

    This paper presents the mechanical design for a new five fingered, twenty degree-of-freedom dexterous hand patterned after human anatomy and actuated by Shape Memory Alloy artificial muscles. Two experimental prototypes of a finger, one fabricated by traditional means and another fabricated by rapid prototyping techniques, are described and used to evaluate the design. An important aspect of the Rapid Prototype technique used here is that this multi-articulated hand will be fabricated in one step, without requiring assembly, while maintaining its desired mobility. The use of Shape Memory Alloy actuators combined with the rapid fabrication of the non-assembly type hand, reduce considerably its weight and fabrication time. Therefore, the focus of this paper is the mechanical design of a dexterous hand that combines Rapid Prototype techniques and smart actuators. The type of robotic hand described in this paper can be utilized for applications requiring low weight, compactness, and dexterity such as prosthetic devices, space and planetary exploration.

  9. Facilitating Long-Term Retention of Vocabulary: The Second-Hand Cloze.

    ERIC Educational Resources Information Center

    Laufer, Batia; Osimo, Helen

    1991-01-01

    Investigates whether the consistent use of a vocabulary reinforcement technique referred to as "second-hand cloze" can result in a significant improvement in long-term retention of words. It is suggested that, although the second-hand cloze embodies some characteristics of other memorization techniques, it also overcomes their shortcomings. (21…

  10. Evaluation of infectious diseases and clinical microbiology specialists' preferences for hand hygiene: analysis using the multi-attribute utility theory and the analytic hierarchy process methods.

    PubMed

    Suner, Aslı; Oruc, Ozlem Ege; Buke, Cagri; Ozkaya, Hacer Deniz; Kitapcioglu, Gul

    2017-08-31

    Hand hygiene is one of the most effective attempts to control nosocomial infections, and it is an important measure to avoid the transmission of pathogens. However, the compliance of healthcare workers (HCWs) with hand washing is still poor worldwide. Herein, we aimed to determine the best hand hygiene preference of the infectious diseases and clinical microbiology (IDCM) specialists to prevent transmission of microorganisms from one patient to another. Expert opinions regarding the criteria that influence the best hand hygiene preference were collected through a questionnaire via face-to-face interviews. Afterwards, these opinions were examined with two widely used multi-criteria decision analysis (MCDA) methods, the Multi-Attribute Utility Theory (MAUT) and the Analytic Hierarchy Process (AHP). A total of 15 IDCM specialist opinions were collected from diverse private and public hospitals located in İzmir, Turkey. The mean age of the participants was 49.73 ± 8.46, and the mean experience year of the participants in their fields was 17.67 ± 11.98. The findings that we obtained through two distinct decision making methods, the MAUT and the AHP, suggest that alcohol-based antiseptic solution (ABAS) has the highest utility (0.86) and priority (0.69) among the experts' choices. In conclusion, the MAUT and the AHP, decision models developed here indicate that rubbing the hands with ABAS is the most favorable choice for IDCM specialists to prevent nosocomial infection.

  11. Interventions to improve hand hygiene compliance in patient care.

    PubMed

    Gould, Dinah J; Moralejo, Donna; Drey, Nicholas; Chudleigh, Jane H; Taljaard, Monica

    2017-09-01

    Health care-associated infection is a major cause of morbidity and mortality. Hand hygiene is regarded as an effective preventive measure. This is an update of a previously published review. To assess the short- and long-term success of strategies to improve compliance to recommendations for hand hygiene, and to determine whether an increase in hand hygiene compliance can reduce rates of health care-associated infection. We conducted electronic searches of the Cochrane Register of Controlled Trials, PubMed, Embase, and CINAHL. We conducted the searches from November 2009 to October 2016. We included randomised trials, non-randomised trials, controlled before-after studies, and interrupted time series analyses (ITS) that evaluated any intervention to improve compliance with hand hygiene using soap and water or alcohol-based hand rub (ABHR), or both. Two review authors independently screened citations for inclusion, extracted data, and assessed risks of bias for each included study. Meta-analysis was not possible, as there was substantial heterogeneity across studies. We assessed the certainty of evidence using the GRADE approach and present the results narratively in a 'Summary of findings' table. This review includes 26 studies: 14 randomised trials, two non-randomised trials and 10 ITS studies. Most studies were conducted in hospitals or long-term care facilities in different countries, and collected data from a variety of healthcare workers. Fourteen studies assessed the success of different combinations of strategies recommended by the World Health Organization (WHO) to improve hand hygiene compliance. Strategies consisted of the following: increasing the availability of ABHR, different types of education for staff, reminders (written and verbal), different types of performance feedback, administrative support, and staff involvement. Six studies assessed different types of performance feedback, two studies evaluated education, three studies evaluated cues such

  12. Finger tips detection for two handed gesture recognition

    NASA Astrophysics Data System (ADS)

    Bhuyan, M. K.; Kar, Mithun Kumar; Neog, Debanga Raj

    2011-10-01

    In this paper, a novel algorithm is proposed for fingertips detection in view of two-handed static hand pose recognition. In our method, finger tips of both hands are detected after detecting hand regions by skin color-based segmentation. At first, the face is removed in the image by using Haar classifier and subsequently, the regions corresponding to the gesturing hands are isolated by a region labeling technique. Next, the key geometric features characterizing gesturing hands are extracted for two hands. Finally, for all possible/allowable finger movements, a probabilistic model is developed for pose recognition. Proposed method can be employed in a variety of applications like sign language recognition and human-robot-interactions etc.

  13. Hands-free human-machine interaction with voice

    NASA Astrophysics Data System (ADS)

    Juang, B. H.

    2004-05-01

    Voice is natural communication interface between a human and a machine. The machine, when placed in today's communication networks, may be configured to provide automation to save substantial operating cost, as demonstrated in AT&T's VRCP (Voice Recognition Call Processing), or to facilitate intelligent services, such as virtual personal assistants, to enhance individual productivity. These intelligent services often need to be accessible anytime, anywhere (e.g., in cars when the user is in a hands-busy-eyes-busy situation or during meetings where constantly talking to a microphone is either undersirable or impossible), and thus call for advanced signal processing and automatic speech recognition techniques which support what we call ``hands-free'' human-machine communication. These techniques entail a broad spectrum of technical ideas, ranging from use of directional microphones and acoustic echo cancellatiion to robust speech recognition. In this talk, we highlight a number of key techniques that were developed for hands-free human-machine communication in the mid-1990s after Bell Labs became a unit of Lucent Technologies. A video clip will be played to demonstrate the accomplishement.

  14. Medicare and Medicaid programs; fire safety requirements for certain health care facilities; amendment. Interim final rule with comment period.

    PubMed

    2005-03-25

    This interim final rule with comment period adopts the substance of the April 15, 2004 temporary interim amendment (TIA) 00-1 (101), Alcohol Based Hand Rub Solutions, an amendment to the 2000 edition of the Life Safety Code, published by the National Fire Protection Association (NFPA). This amendment will allow certain health care facilities to place alcohol-based hand rub dispensers in egress corridors under specified conditions. This interim final rule with comment period also requires that nursing facilities install smoke detectors in resident rooms and public areas if they do not have a sprinkler system installed throughout the facility or a hard-wired smoke detection system in those areas.

  15. Hand-Based Biometric Analysis

    NASA Technical Reports Server (NTRS)

    Bebis, George

    2013-01-01

    Hand-based biometric analysis systems and techniques provide robust hand-based identification and verification. An image of a hand is obtained, which is then segmented into a palm region and separate finger regions. Acquisition of the image is performed without requiring particular orientation or placement restrictions. Segmentation is performed without the use of reference points on the images. Each segment is analyzed by calculating a set of Zernike moment descriptors for the segment. The feature parameters thus obtained are then fused and compared to stored sets of descriptors in enrollment templates to arrive at an identity decision. By using Zernike moments, and through additional manipulation, the biometric analysis is invariant to rotation, scale, or translation or an input image. Additionally, the analysis uses re-use of commonly seen terms in Zernike calculations to achieve additional efficiencies over traditional Zernike moment calculation.

  16. Fat suppression at three-dimensional T1-weighted MR imaging of the hands: Dixon method versus CHESS technique.

    PubMed

    Kirchgesner, T; Perlepe, V; Michoux, N; Larbi, A; Vande Berg, B

    2018-01-01

    To compare the effectiveness of fat suppression and the image quality of the Dixon method with those of the chemical shift-selective (CHESS) technique in hands of normal subjects at non-enhanced three-dimensional (3D) T1-weighted MR imaging. Both hands of 14 healthy volunteers were imaged with 3D fast spoiled gradient echo (FSPGR) T1-weighted Dixon, 3D FSPGR T1-weighted CHESS and 3D T1-weighted fast spin echo (FSE) CHESS sequences in a 1.5T MR scanner. Three radiologists scored the effectiveness of fat suppression in bone marrow (EFS BM ) and soft tissues (EFS ST ) in 20 joints per subject. One radiologist measured the signal-to-noise ratio (SNR) in 10 bones per subject. Statistical analysis used two-way ANOVA with random effects (P<0.0083), paired t-test (P<0.05) and observed agreement to assess differences in effectiveness of fat suppression, differences in SNR and interobserver agreement. EFS BM was statistically significantly higher for the 3D FSPGR T1-weighted Dixon than for the 3D FSPGR T1-weighted CHESS sequence and the 3D FSE T1-weighted CHESS sequence (P<0.0001). EFS ST was statistically significantly higher for the 3D FSPGR T1-weighted Dixon than for the 3D FSPGR T1-weighted CHESS sequence (P<0.0011) and for the 3D FSE T1-weighted CHESS sequence in the axial plane (P=0.0028). Mean SNR was statistically significantly higher for 3D FSPGR T1-weighted Dixon sequence than for 3D FSPGR T1-weighted CHESS and 3D FSE T1-weighted CHESS sequences (P<0.0001). The Dixon method yields more effective fat suppression and higher SNR than the CHESS technique at 3D T1-weighted MR imaging of the hands. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  17. Hand hygiene prior to contact lens handling is problematical.

    PubMed

    McMonnies, Charles W

    2012-04-01

    To establish guidelines for contact lens wearers' hand hygiene practices which achieve a balance between minimising risk of infection and reasonable expectations on the ability of patients to follow them. Evidence has been obtained from publications via PubMed, Advanced Medline Search, Cochrane Reviews, Google Scholar and using the key words hand hygiene, washing and contact lens. Guidelines for effective hand washing and the bother involved vary according to the level of hygiene required. High levels of non-compliance with hand hygiene practices, even among healthcare workers, gives an indication of how important the level of bother involved when following guidelines can be in contributing to non-compliance. Better patient education to improve hand washing techniques as well as patient attitudes toward hand hygiene are needed to reduce high non-compliance levels. Better hand hygiene techniques and higher frequency of their application give the prospect of reduced risk of infection and of any discomfort that arises from increased lens and ocular bioburden. In order that adoption rates might be maximised, the guidelines which have been distilled from this review attempt to strike a balance between technique redundancy and the associated higher levels of hygiene achieved and the possibility that the perception of too much bother involved could reduce participation rates. The guidelines have been expanded by the inclusion of suggested explanatory information in the expectation that helping patients to understand why the recommendations are made will have the effect of increasing their adoption. Copyright © 2011 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  18. Novel Concept of Attaching Endoscope Holder to Microscope for Two Handed Endoscopic Tympanoplasty.

    PubMed

    Khan, Mubarak M; Parab, Sapna R

    2016-06-01

    The well established techniques in tympanoplasty are routinely performed with operating microscopes for many decades now. Endoscopic ear surgeries provide minimally invasive approach to the middle ear and evolving new science in the field of otology. The disadvantage of endoscopic ear surgeries is that it is one-handed surgical technique as the non-dominant left hand of the surgeon is utilized for holding and manipulating the endoscope. This necessitated the need for development of the endoscope holder which would allow both hands of surgeon to be free for surgical manipulation and also allow alternate use of microscope during tympanoplasty. To report the preliminary utility of our designed and developed endoscope holder attachment gripping to microscope for two handed technique of endoscopic tympanoplasty. Prospective Non Randomized Clinical Study. Our endoscope holder attachment for microscope was designed and developed to aid in endoscopic ear surgery and to overcome the disadvantage of single handed endoscopic surgery. It was tested for endoscopic Tympanoplasty. The design of the endoscope holder attachment is described in detail along with its manipulation and manoeuvreing. A total of 78 endoholder assisted type 1 endoscopic cartilage tympanoplasties were operated to evaluate its feasibility for the two handed technique and to evaluate the results of endoscopic type 1 cartilage tympanoplasty. In early follow up period ranging from 6 to 20 months, the graft uptake was seen in 76 ears with one residual perforation and 1 recurrent perforations giving a success rate of 97.435 %. Our endocsope holder attachment for gripping microscope is a good option for two handed technique in endoscopic type 1 cartilage tympanoplasty. The study reports the successful application and use of our endoscope holder attachment for gripping microscope in two handed technique of endoscopic type 1 cartilage tympanoplasty and comparable results with microscopic techniques. IV.

  19. Does intraoperative navigation improve the accuracy of pedicle screw placement in the apical region of dystrophic scoliosis secondary to neurofibromatosis type I: comparison between O-arm navigation and free-hand technique.

    PubMed

    Jin, Mengran; Liu, Zhen; Liu, Xingyong; Yan, Huang; Han, Xiao; Qiu, Yong; Zhu, Zezhang

    2016-06-01

    To assess the accuracy of O-arm-navigation-based pedicle screw insertion in dystrophic scoliosis secondary to NF-1 and compare it with free-hand pedicle screw insertion technique. 32 patients with dystrophic NF-1-associated scoliosis were divided into two groups. A total of 92 pedicle screws were implanted in apical region (two vertebrae above and below the apex each) in 13 patients using O-arm-based navigation (O-arm group), and 121 screws were implanted in 19 patients using free-hand technique (free-hand group). The postoperative CT images were reviewed and analyzed for pedicle violation. The screw penetration was divided into four grades: grade 0 (ideal placement), grade 1 (penetration <2 mm), grade 2 (penetration between 2 and 4 mm), and grade 3 (penetration >4 mm). The accuracy rate of pedicle screw placement (grade 0, 1) was significantly higher in the O-arm group (79 %, 73/92) compared to 67 % (81/121) of the free-hand group (P = 0.045). Meanwhile, a significantly lower prevalence of grade 2-3 perforation was observed in the O-arm group (21 vs. 33 %, P < 0.05), and the incidence of medial perforation was significantly minimized by using O-arm navigation compared to free-hand technique (2 vs. 15 %, P < 0.01). Moreover, the implant density in apical region was significantly elevated by using O-arm navigation (58 vs. 42 %, P < 0.001). We reported 79 % accuracy of O-arm-based pedicle screw placement in dystrophic NF-1-associated scoliosis. O-arm navigation system does facilitate pedicle screw insertion in dystrophic NF-1-associated scoliosis, demonstrating superiorities in the safety and accuracy of pedicle screw placement in comparison with free-hand technique.

  20. Toe-to-hand transfer.

    PubMed

    Yoshimura, M

    1980-07-01

    Toe-to-hand transfer was performed in 28 patients, involving 33 fingers, using microvascular technique. Of this number, 26 patients (31 fingers) had experienced trauma, and the remaining 2 patients (2 fingers) had a congenital deformity. The toew used for grafting were the great toe (1), the second tow (30), and third toe (2). Success was achieved in all cases, sensory recovery was good, and remarkable improvement was attained in function and cosmetic appearance. Metacarpal hand, amputation of thumb, and amputation thumb and three fingers were good indications for this procedure, which gave satisfactory aesthetic results, even in patients with amputation of single digits.

  1. Multiple faces of contemporary hand knitting

    NASA Astrophysics Data System (ADS)

    Pavko-Čuden, A.

    2017-10-01

    Knitting and crocheting are traditional textile techniques with great significance both in history and modern times. Similar to other textile techniques, knitting has developed into a diversified industrial sector, comprising the production of knitted fabrics, knitwear, hosiery and fashion accessories. At the same time, contemporary knitting and crocheting became hobbies as well as arts-and-crafts activities, extending to various areas of work and leisure. Historical and traditional ethnic knitting and crocheting patterns keep inspiring designers’ collections and also other industrial products. Not so long ago, knitting was seen as an ordinary and unchanging indoor activity and, in its domestic history, it was the preserve of older women making products of dainty work and taste. Today, knitting deals with urban population of all classes. The popularity of leisure hand knitting is increasing; moreover, hand knitting is becoming more and more widespread among young people. With the emergence of artistic and handicraft markets, hand-knitting and crocheting developed into a profitable market activity. Positive effects of hand knitting have become increasingly important - from generating creativity and innovativeness, through knitting and socializing in groups, to medical and therapeutic effects as well as social and global connections. Yarn bombing, yarn storming or graffiti knitting has been used to describe urban social practices of knitted objects placed, or tagged, in public spaces. Knitting became means of communication, artistic and social expression and statement. The advantage of hand knitting is its mobility. One can knit almost everywhere, and for hand knitting, only a ball of yarn and knitting needles are required. Handknitted products have nice touch, they are custom-made and therefore personalized.

  2. Hand-Based Biometric Analysis

    NASA Technical Reports Server (NTRS)

    Bebis, George (Inventor); Amayeh, Gholamreza (Inventor)

    2015-01-01

    Hand-based biometric analysis systems and techniques are described which provide robust hand-based identification and verification. An image of a hand is obtained, which is then segmented into a palm region and separate finger regions. Acquisition of the image is performed without requiring particular orientation or placement restrictions. Segmentation is performed without the use of reference points on the images. Each segment is analyzed by calculating a set of Zernike moment descriptors for the segment. The feature parameters thus obtained are then fused and compared to stored sets of descriptors in enrollment templates to arrive at an identity decision. By using Zernike moments, and through additional manipulation, the biometric analysis is invariant to rotation, scale, or translation or an in put image. Additionally, the analysis utilizes re-use of commonly-seen terms in Zernike calculations to achieve additional efficiencies over traditional Zernike moment calculation.

  3. Nursing Care Hour Standards Study. Part 5 thru Part 8

    DTIC Science & Technology

    1981-09-01

    undressing, into shower, with bath and hair shampoo , assist in redressing, and back into the wheelchair. (Must remain with patient and provide assistance...from area. (Buttocks, hips, shoulders , heels.) BACK RUB: Place equipment at patient’s bedside, remove pajama top, 1 turn patient to expose back, rub back...NAIL CARE: Place equipment at bedside, wash hands/feet and 1 nails, trim and clean finger/toe nails, remove equipment from area. SHAMPOO : Place equipment

  4. Does the clinical use of ethanol-based hand sanitizer elevate blood alcohol levels? A prospective study.

    PubMed

    Miller, Michael A; Rosin, Alex; Levsky, Marc E; Patel, Manish M; Gregory, Timothy J D; Crystal, Chad S

    2006-11-01

    Ethanol-based hand sanitizers (EBHSs) are used in most health care facilities in the United States. Infection control personnel advocate the use of generous quantities of EBHS before and after contact with patients. Although it is assumed that little systemic absorption of ethanol occurs during EBHS use, many alcohols are absorbed to varying degrees via the transdermal route. Ethanol intoxication by employees in the medical workplace is a potentially serious finding, and it is of forensic and medical-legal importance to elucidate the effects of frequent use of EBHS upon serum blood ethanol levels (BELs). To investigate the effect of frequent use of EBHS upon serum blood ethanol concentrations, we prospectively studied 5 volunteers undergoing frequent application of EBHS. Enrolled subjects applied 5 mL of the product (62% denatured ethyl alcohol manufactured by Kimberley-Clark, Roswell, GA) to both hands and rubbed until dry. This activity was repeated 50 times over 4 hours. Participants had their blood drawn before as well as after completing the study. Each participant was without alcohol exposure during the 12 hours preceding the study. Five volunteers were enrolled. All had an initial blood ethanol level of less than 5 mg/dL. All 5 participants completed the 4-hour study. There were no noted adverse reactions during the study. Blood ethanol level upon completion of the 50 applications of EBHS was less than 5 mg/dL in all 5 study participants. The results of this study demonstrate that use of ethanol-based hand sanitizers, when frequently used in accordance with labeling, do not raise serum blood ethanol levels.

  5. Perineal injury associated with hands on/hands poised and directed/undirected pushing: A retrospective cross-sectional study of non-operative vaginal births, 2011-2016.

    PubMed

    Lee, Nigel; Firmin, Meaghan; Gao, Yu; Kildea, Sue

    2018-07-01

    Clinicians hand position and advised pushing techniques may impact on rates of perineal injury. To assess the association of four techniques used in management of second stage with risk of moderate and severe perineal injury. Retrospective cross-sectional study. A metropolitan maternity hospital and a private maternity hospital in Brisbane, Australia. Term women with singleton, cephalic presentation experiencing a non-operative vaginal birth from January 2011 to December 2016. The research sites perinatal database recorded data on clinicians approach to instructing women during second stage and hand position at birth. Women were identified from matching the inclusion criteria (n = 26,393) then grouped based on combinations of hands-on, hand- poised, directed and undirected pushing. The associations with perineal injury were estimated using odds ratios obtained by multivariate analysis. Primary outcomes were the risk of moderate and severe perineal injury. The significance was set at 0.001. In Nulliparous women there was no difference in the risk of moderate or severe perineal injury between the different techniques. In multiparous women the use of a hands-on/directed approach was associated with a significant increase in the risk of moderate (AOR 1.18, 95% CI 1.10-1.27, p < 0.001) and severe perineal injury (AOR 1.50, 95% CI 1.20-1.88, p < 0.001) compared to hands-poised/undirected. A hands poised/undirected approach could be utilised in strategies for the prevention of moderate and severe perineal injury. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. The Free-Hand Technique for S2-Alar-Iliac Screw Placement: A Safe and Effective Method for Sacropelvic Fixation in Adult Spinal Deformity.

    PubMed

    Shillingford, Jamal N; Laratta, Joseph L; Tan, Lee A; Sarpong, Nana O; Lin, James D; Fischer, Charla R; Lehman, Ronald A; Kim, Yongjung J; Lenke, Lawrence G

    2018-02-21

    Spinopelvic fixation is an integral part of achieving solid fusion across the lumbosacral junction, especially in deformity procedures requiring substantial correction or long-segment constructs. Traditional S2-alar-iliac (S2AI) screw-placement techniques utilize fluoroscopy, increasing operative time and radiation exposure to the patient and surgeon. We describe a novel free-hand technique for S2AI screw placement in patients with adult spinal deformity. We reviewed the records of 45 consecutive patients who underwent spinopelvic fixation performed with use of S2AI screws by the senior surgeon and various fellows or residents over a 12-month period (2015 to 2016). In each case, the S2AI screws were placed utilizing a free-hand technique without fluoroscopic or image guidance. Screw position and accuracy were assessed by intraoperative O-arm imaging and analyzed using 3-dimensional interactive manipulation of computed tomography images. A total of 100 screws were placed, 51 by the senior surgeon and 49 by trainees. The mean patient age was 57.4 ± 12.7 years at the time of surgery; 37 (82.2%) of the patients were female. Preoperative diagnoses included adult idiopathic scoliosis (n = 19), adult degenerative scoliosis (n = 15), flatback syndrome (n = 2), fixed sagittal imbalance (n = 6), and distal junctional kyphosis (n = 3). Five (5%) of the screws were placed with moderate to severe cortical breaches, all of which perforated the pelvis posteriorly, with no clinically notable neurovascular or visceral complications. The breach rate did not differ significantly between the senior surgeon and trainees. The free-hand technique for S2AI screw placement, when performed in a standardized manner, was demonstrated to be safe and reliable in constructs requiring spinopelvic fixation. The accuracy of screw placement relies on visible and palpable anatomic landmarks that obviate the need for intraoperative fluoroscopy or image guidance, potentially reducing operative time

  7. The failures of root canal preparation with hand ProTaper.

    PubMed

    Bătăiosu, Marilena; Diaconu, Oana; Moraru, Iren; Dăguci, C; Tuculină, Mihaela; Dăguci, Luminiţa; Gheorghiţă, Lelia

    2012-07-01

    The failures of root canal preparation are due to some anatomical deviation (canal in "C" or "S") and some technique errors. The technique errors are usually present in canal root cleansing and shaping stage and are the result of endodontic treatment objectives deviation. Our study was made on technique errors while preparing the canal roots with hand ProTaper. Our study was made "in vitro" on 84 extracted teeth (molars, premolars, incisors and canines). The canal root of these teeth were cleansed and shaped with hand ProTaper by crown-down technique and canal irrigation with NaOCl(2,5%). The dental preparation control was made by X-ray. During canal root preparation some failures were observed like: canal root overinstrumentation, zipping and stripping phenomenon, discarded and/or fractured instruments. Hand ProTaper represents a revolutionary progress of endodontic treatment, but a deviation from accepted rules of canal root instrumentation can lead to failures of endodontic treatment.

  8. The failures of root canal preparation with hand ProTaper

    PubMed Central

    Bătăiosu, Marilena; Diaconu, Oana; Moraru, Iren; Dăguci, C.; Ţuculină, Mihaela; Dăguci, Luminiţa; Gheorghiţă, Lelia

    2012-01-01

    The failures of root canal preparation are due to some anatomical deviation (canal in “C” or “S”) and some technique errors. The technique errors are usually present in canal root cleansing and shaping stage and are the result of endodontic treatment objectives deviation. Objectives: Our study was made on technique errors while preparing the canal roots with hand ProTaper. Methodology: Our study was made “in vitro” on 84 extracted teeth (molars, premolars, incisors and canines). The canal root of these teeth were cleansed and shaped with hand ProTaper by crown-down technique and canal irrigation with NaOCl(2,5%). The dental preparation control was made by X-ray. Results: During canal root preparation some failures were observed like: canal root overinstrumentation, zipping and stripping phenomenon, discarded and/or fractured instruments. Conclusions: Hand ProTaper represents a revolutionary progress of endodontic treatment, but a deviation from accepted rules of canal root instrumentation can lead to failures of endodontic treatment. PMID:24778848

  9. Evaluating Remapped Physical Reach for Hand Interactions with Passive Haptics in Virtual Reality.

    PubMed

    Han, Dustin T; Suhail, Mohamed; Ragan, Eric D

    2018-04-01

    Virtual reality often uses motion tracking to incorporate physical hand movements into interaction techniques for selection and manipulation of virtual objects. To increase realism and allow direct hand interaction, real-world physical objects can be aligned with virtual objects to provide tactile feedback and physical grasping. However, unless a physical space is custom configured to match a specific virtual reality experience, the ability to perfectly match the physical and virtual objects is limited. Our research addresses this challenge by studying methods that allow one physical object to be mapped to multiple virtual objects that can exist at different virtual locations in an egocentric reference frame. We study two such techniques: one that introduces a static translational offset between the virtual and physical hand before a reaching action, and one that dynamically interpolates the position of the virtual hand during a reaching motion. We conducted two experiments to assess how the two methods affect reaching effectiveness, comfort, and ability to adapt to the remapping techniques when reaching for objects with different types of mismatches between physical and virtual locations. We also present a case study to demonstrate how the hand remapping techniques could be used in an immersive game application to support realistic hand interaction while optimizing usability. Overall, the translational technique performed better than the interpolated reach technique and was more robust for situations with larger mismatches between virtual and physical objects.

  10. A Gram Stain Hands-On Workshop Enhances First Year Medical Students' Technique Competency in Comprehension and Memorization.

    PubMed

    Delfiner, Matthew S; Martinez, Luis R; Pavia, Charles S

    2016-01-01

    Laboratory diagnostic tests have an essential role in patient care, and the increasing number of medical and health professions schools focusing on teaching laboratory medicine to pre-clinical students reflects this importance. However, data validating the pedagogical methods that best influence students' comprehension and interpretation of diagnostic tests have not been well described. The Gram stain is a simple yet significant and frequently used diagnostic test in the clinical setting that helps classify bacteria into two major groups, Gram positive and negative, based on their cell wall structure. We used this technique to assess which educational strategies may improve students' learning and competency in medical diagnostic techniques. Hence, in this randomized controlled study, we compared the effectiveness of several educational strategies (e.g. workshop, discussion, or lecture) in first year medical students' competency in comprehension and interpretation of the Gram stain procedure. We demonstrated that a hands-on practical workshop significantly enhances students' competency in memorization and overall comprehension of the technique. Interestingly, most students irrespective of their cohort showed difficulty in answering Gram stain-related analytical questions, suggesting that more emphasis should be allocated by the instructors to clearly explain the interpretation of the diagnostic test results to students in medical and health professional schools. This proof of principle study highlights the need of practical experiences on laboratory medical techniques during pre-clinical training to facilitate future medical doctors' and healthcare professionals' basic understanding and competency in diagnostic testing for better patient care.

  11. Effects of intensive repetition of a new facilitation technique on motor functional recovery of the hemiplegic upper limb and hand

    PubMed Central

    Kawahira, Kazumi; Shimodozono, Megumi; Etoh, Seiji; Kamada, Katsuya; Noma, Tomokazu; Tanaka, Nobuyuki

    2010-01-01

    Objective To study the effects on the hemiplegic upper limb of repetitive facilitation exercises (RFEs) using a novel facilitation technique, in which the patient's intention to move the hemiplegic upper limb or finger was followed by realization of the movement using multiple sensory stimulations. Methods Twenty-three stroke patients were enrolled in a cross-over study in which 2-week RFE sessions (100 repetitions each of five-to-eight types of facilitation exercise per day) were alternated with 2-week conventional rehabilitation (CR) sessions, for a total of four sessions. Treatments were begun with the 2-week RFE session in one group and the 2-week CR session in the second group. Results After the first 2-week RFE session, both groups showed improvements in the Brunnstrom stages of the upper limb and the hand, in contrast to the small improvements observed during the first CR session. The Simple Test for Evaluating Hand Function (STEF) score, which evaluates the ability of manipulating objects, in both groups improved during both sessions. After the second 2-week RFE and CR sessions, both groups showed little further improvement except in the STEF score. Conclusion The novel RFEs promoted the functional recovery of the hemiplegic upper limb and hand to a greater extent than the CR sessions. PMID:20715890

  12. Hands-on Simulation versus Traditional Video-learning in Teaching Microsurgery Technique

    PubMed Central

    SAKAMOTO, Yusuke; OKAMOTO, Sho; SHIMIZU, Kenzo; ARAKI, Yoshio; HIRAKAWA, Akihiro; WAKABAYASHI, Toshihiko

    2017-01-01

    Bench model hands-on learning may be more effective than traditional didactic practice in some surgical fields. However, this has not been reported for microsurgery. Our study objective was to demonstrate the efficacy of bench model hands-on learning in acquiring microsuturing skills. The secondary objective was to evaluate the aptitude for microsurgery based on personality assessment. Eighty-six medical students comprising 62 men and 24 women were randomly assigned to either 20 min of hands-on learning with a bench model simulator or 20 min of video-learning using an instructional video. They then practiced microsuturing for 40 min. Each student then made three knots, and the time to complete the task was recorded. The final products were scored by two independent graders in a blind fashion. All participants then took a personality test, and their microsuture test scores and the time to complete the task were compared. The time to complete the task was significantly shorter in the simulator group than in the video-learning group. The final product scores tended to be higher with simulator-learning than with video-learning, but the difference was not significant. Students with high “extraversion” scores on the personality inventory took a shorter time to complete the suturing test. Simulator-learning was more effective for microsurgery training than video instruction, especially in understanding the procedure. There was a weak association between personality traits and microsurgery skill. PMID:28381653

  13. Cement technique for reducing post-operative bursitis after trochanteric fixation.

    PubMed

    Derman, Peter B; Horneff, John G; Kamath, Atul F; Garino, Jonathan

    2013-02-01

    Post-operative trochanteric bursitis is a known complication secondary to the surgical approach in total hip arthroplasty. This phenomenon may be partially attributable to repetitive microtrauma generated when soft tissues rub against implanted hardware. Significant rates of post-operative trochanteric bursitis have been observed following procedures in which a trochanteric fixation device, such as a bolt-washer mechanism or a cable-grip/claw system, is used to secure the trochanteric fragment after trochanteric osteotomy. We present a simple technique for use with a bolt-washer system or grip plate in which trochanteric components are covered in bone wax followed by a layer of cement to decrease friction and to diminish the risk of post-operative bursitis.

  14. Hand sensibility measures used by therapists.

    PubMed

    Mielke, K; Novak, C B; Mackinnon, S E; Feely, C A

    1996-03-01

    Sensory evaluations are frequently used to assess patients with functional loss resulting from nerve injury. The results of these tests are routinely utilized by hand surgeons as an indication for conservative management or surgical intervention in the evaluation of surgical outcome and in the determination of disability ratings. Reports in the literature regarding specific tests for sensibility show variation in their application. The purpose of this study was to evaluate which tests are used to evaluate hand sensibility and the techniques of application currently used by hand therapists. Two hundred members of the American Society of Hand Therapists were randomly selected and a survey was sent to these members. The results of this study identify the need to develop standardized protocols for sensory evaluations and the need for therapists to follow the standardized methods for administration of moving and static two-point discrimination, and Semmes-Weinstein monofilaments, if comparisons of results between centers are to be meaningful.

  15. Effect of surgical hand scrub time on subsequent bacterial growth.

    PubMed

    Wheelock, S M; Lookinland, S

    1997-06-01

    In this experimental study, the researchers evaluated the effect of surgical hand scrub time on subsequent bacterial growth and assessed the effectiveness of the glove juice technique in a clinical setting. In a randomized crossover design, 25 perioperative staff members scrubbed for two or three minutes in the first trial and vice versa in the second trial, after which the wore sterile surgical gloves for one hour under clinical conditions. The researchers then sampled the subjects' nondominant hands for bacterial growth, cultured aliquots from the sampling solution, and counted microorganisms. Scrubbing for three minutes produced lower mean log bacterial counts than scrubbing for two minutes. Although the mean bacterial count differed significantly (P = .02) between the two-minute and three-minute surgical hand scrub times, it fell below 0.5 log, which is the threshold for practical and clinical significance. This finding suggests that a two-minute surgical hand scrub is clinically as effective as a three-minute surgical had scrub. The glove juice technique demonstrated sensitivity and reliability in enumerating bacteria on the hands of perioperative staff members in a clinical setting.

  16. Hand and Wrist Injuries in Boxing and the Martial Arts.

    PubMed

    Drury, Benjamin Todd; Lehman, Thomas P; Rayan, Ghazi

    2017-02-01

    Hand and wrist injuries in martial arts are typically a reflection of the combat nature of this discipline. In striking sports, the axial load mechanism of injury is common and causes fractures and dislocations; in grappling sports, sprain injuries and degenerative changes predominate. There is clear evidence to support that hand protection reduces the risk of hand injury. Traditional training in martial arts on proper technique and target selection in striking sports reduces the risk of hand injury, and is an important component of hand and wrist injury prevention. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Nail-Gun Injuries to the Hand

    PubMed Central

    Pierpont, Yvonne N.; Pappas-Politis, Effie; Naidu, Deepak K.; Salas, R. Emerick; Johnson, Erika L.; Payne, Wyatt G.

    2008-01-01

    Background: The nail gun is a commonly utilized tool in carpentry and construction. When used properly with appropriate safety precautions, it can facilitate production and boost efficiency; however, this powerful tool also has the potential to cause serious injury. The most common site of nail-gun injuries in both industrial and nonoccupational settings is the hand. Materials and Methods: We report on two patients with nail-gun injuries to the hand. A review of the literature and discussion of clinical evaluation and treatment of nail-gun injuries to the hand are presented. Results: Two patients present with soft tissue injuries to the hand with the nail embedded and intact at the injury site. Operative removal of the nail and wound care resulted in successful treatment in both cases. Nail-gun injuries to the hand vary in severity on the basis of the extent of structural damage. Treatment is based on the severity of injury and the presence and location of barbs on the penetrating nail. Conclusion: Healthcare providers must understand and educate patients on the prevention mechanics of nail-gun injuries. Nail-gun injuries to the hand necessitate appropriate evaluation techniques, understanding of surgical management versus nonsurgical management, and awareness of potential pitfalls in treatment. PMID:19079574

  18. Handwashing practices and challenges in Bangladesh.

    PubMed

    Hoque, B A

    2003-06-01

    Handwashing is universally promoted in health interventions. Studies in Bangladesh and elsewhere have shown a 14 - 40% reduction of diarrhoeal diseases with handwashing. The perceptions and methods related to washing of hands vary widely in Bangladesh. Socio-economic factors are also associated with methods practised. In general, the effectiveness of handwashing practices is poor. Faecal coliform bacteriological counts were reported to be high for both left and right hands. About 85% of women studied who lived in slums and 41% of rural women washed their hands using only water. However, most women rubbed their hands on the ground, or used soil, and rinsed them with water during post-defecation handwashing. Most women claimed that they could not afford to buy soap. Experimental trials showed that use of soap, ash or soil gave similar results when women washed their hands under the same conditions. The washing of both hands, rubbing of hands, and the amount and quality of rinsing water used were found to be important determinants in the reduction of bacterial counts on hands. Although handwashing messages have been revised by most of the main programmes after these studies, there is scope for further improvement, as well as evaluation of their impact.

  19. The accuracy, precision and sustainability of different techniques for tablet subdivision: breaking by hand and the use of tablet splitters or a kitchen knife.

    PubMed

    van Riet-Nales, Diana A; Doeve, Myrthe E; Nicia, Agnes E; Teerenstra, Steven; Notenboom, Kim; Hekster, Yechiel A; van den Bemt, Bart J F

    2014-05-15

    Tablets are frequently subdivided to lower the dose, to facilitate swallowing by e.g. children or older people or to save costs. Splitting devices are commonly used when hand breaking is difficult or painful. Three techniques for tablet subdivision were investigated: hand breaking, tablet splitter, kitchen knife. A best case drug (paracetamol), tablet (round, flat, uncoated, 500 mg) and operator (24-year student) were applied. Hundred tablets were subdivided by hand and by three devices of each of the following types: Fit & Healthy, Health Care Logistics, Lifetime, PillAid, PillTool, Pilomat tablet splitter; Blokker kitchen knife. The intra and inter device accuracy, precision and sustainability were investigated. The compliance to (adapted) regulatory requirements was investigated also. The accuracy and precision of hand broken tablets was 104/97% resp. 2.8/3.2% (one part per tablet considered; parts right/left side operator). The right/left accuracies of the splitting devices varied between 60 and 133%; the precisions 4.0 and 29.6%. The devices did not deteriorate over 100-fold use. Only hand broken tablets complied with all regulatory requirements. Health care professionals should realize that tablet splitting may result in inaccurate dosing. Authorities should undertake appropriate measures to assure good function of tablet splitters and, where feasible, to reduce the need for their use. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Left-handed skeletally mature baseball players have smaller humeral retroversion in the throwing arm than right-handed players.

    PubMed

    Takenaga, Tetsuya; Goto, Hideyuki; Sugimoto, Katsumasa; Tsuchiya, Atsushi; Fukuyoshi, Masaki; Nakagawa, Hiroki; Nozaki, Masahiro; Takeuchi, Satoshi; Otsuka, Takanobu

    2017-12-01

    It is known that the humeral retroversion of baseball players is greater in the throwing arm than in the nonthrowing arm. An investigation measuring dry bone specimens also showed that the right humerus had greater retroversion than the left. Considering these facts, it was hypothesized that humeral retroversion would differ between right- and left-handed players. This study aimed to compare the bilateral humeral retroversion between right- and left-handed skeletally mature baseball players. We investigated 260 (196 right-handed and 64 left-handed) male baseball players who belonged to a college or amateur team. Bilateral humeral retroversion was assessed using an ultrasound-assisted technique (humeral torsion angle [HTA]) as described by previous studies. Analysis of covariance, adjusted for handedness and baseball position, assessed the effect of throwing arm dominance on HTA. In comparison of the throwing arm, HTA was significantly smaller in left-handed (left humerus) than in right-handed (right humerus) players (77° vs. 81°; P < .001). In comparison of the nonthrowing arm, HTA was significantly greater in left-handed (right humerus) than in right-handed (left humerus) players (73° vs. 69°; P < .001). The mean side-to-side difference of HTA was significantly smaller in left-handed than in right-handed players (3° vs. 12°; P < .001). Humeral retroversion of left-handed skeletally mature baseball players was significantly smaller in the throwing arm, greater in the nonthrowing arm, and smaller in side-to-side differences than that of right-handed players. These findings may be key to understanding some of the biomechanical differences between right- and left-handed baseball players. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Unconstrained and contactless hand geometry biometrics.

    PubMed

    de-Santos-Sierra, Alberto; Sánchez-Ávila, Carmen; Del Pozo, Gonzalo Bailador; Guerra-Casanova, Javier

    2011-01-01

    This paper presents a hand biometric system for contact-less, platform-free scenarios, proposing innovative methods in feature extraction, template creation and template matching. The evaluation of the proposed method considers both the use of three contact-less publicly available hand databases, and the comparison of the performance to two competitive pattern recognition techniques existing in literature: namely support vector machines (SVM) and k-nearest neighbour (k-NN). Results highlight the fact that the proposed method outcomes existing approaches in literature in terms of computational cost, accuracy in human identification, number of extracted features and number of samples for template creation. The proposed method is a suitable solution for human identification in contact-less scenarios based on hand biometrics, providing a feasible solution to devices with limited hardware requirements like mobile devices.

  2. Unconstrained and Contactless Hand Geometry Biometrics

    PubMed Central

    de-Santos-Sierra, Alberto; Sánchez-Ávila, Carmen; del Pozo, Gonzalo Bailador; Guerra-Casanova, Javier

    2011-01-01

    This paper presents a hand biometric system for contact-less, platform-free scenarios, proposing innovative methods in feature extraction, template creation and template matching. The evaluation of the proposed method considers both the use of three contact-less publicly available hand databases, and the comparison of the performance to two competitive pattern recognition techniques existing in literature: namely Support Vector Machines (SVM) and k-Nearest Neighbour (k-NN). Results highlight the fact that the proposed method outcomes existing approaches in literature in terms of computational cost, accuracy in human identification, number of extracted features and number of samples for template creation. The proposed method is a suitable solution for human identification in contact-less scenarios based on hand biometrics, providing a feasible solution to devices with limited hardware requirements like mobile devices. PMID:22346634

  3. Testing of the World Health Organization-recommended formulations for surgical hand preparation and proposals for increased efficacy.

    PubMed

    Suchomel, M; Kundi, M; Allegranzi, B; Pittet, D; Rotter, M L

    2011-10-01

    The 2009 World Health Organization (WHO) Guidelines on hand hygiene in health care recommend alcohol-based hand rubs for both hygienic and pre-surgical hand treatment. Two formulations based on ethanol 80% v/v and 2-propanol 75% v/v are proposed for local preparation in healthcare settings where commercial products are not available or too expensive. Both formulations and our suggested modifications (using mass rather than volume percent concentrations) were evaluated for their conformity with the efficacy requirements of the forthcoming amendment of the European Norm (EN) 12791, i.e. non-inferiority of a product when compared with a reference procedure (1-propanol 60% v/v for 3 min) immediately and 3 h after antisepsis. In this study, the WHO-recommended formulations were tested for 3 min and 5 min. Neither formulation met the efficacy requirements of EN 12791 with 3 min application. Increasing the respective concentrations to 80 w/w (85% v/v) and 75 w/w (80% v/v), together with a prolonged application of 5 min, rendered the immediate effect of both formulations non-inferior to the reference antisepsis procedure. This was not the case with the 3h effect, which remained significantly inferior to the reference. Although the original formulations do not meet the efficacy requirements of EN 12791, the clinical significance of this finding deserves further clinical trials. To comply with the requirement of EN 12791, an amendment to the formulations is possible by increasing the alcohol concentrations through changing volume into mass percent and prolonging the duration of application from 3 min to 5 min. Copyright © 2011 World Health Organization. Published by Elsevier Ltd on behalf of the Healthcare Infection Society. Published by Elsevier Ltd.. All rights reserved.

  4. Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands

    PubMed Central

    Santello, Marco; Bianchi, Matteo; Gabiccini, Marco; Ricciardi, Emiliano; Salvietti, Gionata; Prattichizzo, Domenico; Ernst, Marc; Moscatelli, Alessandro; Jörntell, Henrik; Kappers, Astrid M.L.; Kyriakopoulos, Kostas; Albu-Schäffer, Alin; Castellini, Claudio; Bicchi, Antonio

    2017-01-01

    The term ‘synergy’ – from the Greek synergia – means ‘working together’. The concept of multiple elements working together towards a common goal has been extensively used in neuroscience to develop theoretical frameworks, experimental approaches, and analytical techniques to understand neural control of movement, and for applications for neuro-rehabilitation. In the past decade, roboticists have successfully applied the framework of synergies to create novel design and control concepts for artificial hands, i.e., robotic hands and prostheses. At the same time, robotic research on the sensorimotor integration underlying the control and sensing of artificial hands has inspired new research approaches in neuroscience, and has provided useful instruments for novel experiments. The ambitious goal of integrating expertise and research approaches in robotics and neuroscience to study the properties and applications of the concept of synergies is generating a number of multidisciplinary cooperative projects, among which the recently finished 4-year European project “The Hand Embodied” (THE). This paper reviews the main insights provided by this framework. Specifically, we provide an overview of neuroscientific bases of hand synergies and introduce how robotics has leveraged the insights from neuroscience for innovative design in hardware and controllers for biomedical engineering applications, including myoelectric hand prostheses, devices for haptics research, and wearable sensing of human hand kinematics. The review also emphasizes how this multidisciplinary collaboration has generated new ways to conceptualize a synergy-based approach for robotics, and provides guidelines and principles for analyzing human behavior and synthesizing artificial robotic systems based on a theory of synergies. PMID:26923030

  5. Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands.

    PubMed

    Santello, Marco; Bianchi, Matteo; Gabiccini, Marco; Ricciardi, Emiliano; Salvietti, Gionata; Prattichizzo, Domenico; Ernst, Marc; Moscatelli, Alessandro; Jörntell, Henrik; Kappers, Astrid M L; Kyriakopoulos, Kostas; Albu-Schäffer, Alin; Castellini, Claudio; Bicchi, Antonio

    2016-07-01

    The term 'synergy' - from the Greek synergia - means 'working together'. The concept of multiple elements working together towards a common goal has been extensively used in neuroscience to develop theoretical frameworks, experimental approaches, and analytical techniques to understand neural control of movement, and for applications for neuro-rehabilitation. In the past decade, roboticists have successfully applied the framework of synergies to create novel design and control concepts for artificial hands, i.e., robotic hands and prostheses. At the same time, robotic research on the sensorimotor integration underlying the control and sensing of artificial hands has inspired new research approaches in neuroscience, and has provided useful instruments for novel experiments. The ambitious goal of integrating expertise and research approaches in robotics and neuroscience to study the properties and applications of the concept of synergies is generating a number of multidisciplinary cooperative projects, among which the recently finished 4-year European project "The Hand Embodied" (THE). This paper reviews the main insights provided by this framework. Specifically, we provide an overview of neuroscientific bases of hand synergies and introduce how robotics has leveraged the insights from neuroscience for innovative design in hardware and controllers for biomedical engineering applications, including myoelectric hand prostheses, devices for haptics research, and wearable sensing of human hand kinematics. The review also emphasizes how this multidisciplinary collaboration has generated new ways to conceptualize a synergy-based approach for robotics, and provides guidelines and principles for analyzing human behavior and synthesizing artificial robotic systems based on a theory of synergies. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands

    NASA Astrophysics Data System (ADS)

    Santello, Marco; Bianchi, Matteo; Gabiccini, Marco; Ricciardi, Emiliano; Salvietti, Gionata; Prattichizzo, Domenico; Ernst, Marc; Moscatelli, Alessandro; Jörntell, Henrik; Kappers, Astrid M. L.; Kyriakopoulos, Kostas; Albu-Schäffer, Alin; Castellini, Claudio; Bicchi, Antonio

    2016-07-01

    The term 'synergy' - from the Greek synergia - means 'working together'. The concept of multiple elements working together towards a common goal has been extensively used in neuroscience to develop theoretical frameworks, experimental approaches, and analytical techniques to understand neural control of movement, and for applications for neuro-rehabilitation. In the past decade, roboticists have successfully applied the framework of synergies to create novel design and control concepts for artificial hands, i.e., robotic hands and prostheses. At the same time, robotic research on the sensorimotor integration underlying the control and sensing of artificial hands has inspired new research approaches in neuroscience, and has provided useful instruments for novel experiments. The ambitious goal of integrating expertise and research approaches in robotics and neuroscience to study the properties and applications of the concept of synergies is generating a number of multidisciplinary cooperative projects, among which the recently finished 4-year European project ;The Hand Embodied; (THE). This paper reviews the main insights provided by this framework. Specifically, we provide an overview of neuroscientific bases of hand synergies and introduce how robotics has leveraged the insights from neuroscience for innovative design in hardware and controllers for biomedical engineering applications, including myoelectric hand prostheses, devices for haptics research, and wearable sensing of human hand kinematics. The review also emphasizes how this multidisciplinary collaboration has generated new ways to conceptualize a synergy-based approach for robotics, and provides guidelines and principles for analyzing human behavior and synthesizing artificial robotic systems based on a theory of synergies.

  7. Rub tolerance evaluation of two sintered NiCrAl gas path seal materials. [wear tests of gas turbine engine seals

    NASA Technical Reports Server (NTRS)

    Bill, R. C.

    1978-01-01

    Two strength level variations of sintered NiCrAl (about 40 percent dense), candidate high pressure turbine seal materials, were subject to rub tolerance testing against AM 355 steel blade tips. The high strength material (17 N/sq mm tensile strength) showed frictional and radial loads that were 20 to 50 percent higher than those measured for the low strength material (15.5 N/ sq mm tensile strength). Measured wear to the AM 355 blade tips was not significantly different for the two sintered NiCrAl seal materials. Wear of the sintered NiCrAl was characterized by material removal to a depth greater than the depth to which blade tips were driven into the seal, indicating self-erosion effects.

  8. Dentistry--a show of hands, please!

    PubMed

    Rucker, Lance M

    2007-01-01

    Dentists have historically derived a distinctive part of their identity from the role of hand skills in practice. Dentistry is a surgical discipline, requiring a basic competency to perform what has been diagnosed and planned as being in the patients' best interests. Dental education has introduced magnification and computer-assisted technique instruction as the proportion of clock-hours devoted to laboratory practice has decreased. The threats posed by traumatic hand injury to practitioners are unknown, but may be small. By contrast, the strain of repetitive motion and injuries caused by postural problems are reported to be widespread in the profession and is generally accepted as characteristic and unavoidable. Ergonomic approaches to alleviating work strain have not been broadly embraced. As dentistry incorporates more biological alternatives and automated technology, the role of hands in practice may change.

  9. On the feasibility of interoperable schemes in hand biometrics.

    PubMed

    Morales, Aythami; González, Ester; Ferrer, Miguel A

    2012-01-01

    Personal recognition through hand-based biometrics has attracted the interest of many researchers in the last twenty years. A significant number of proposals based on different procedures and acquisition devices have been published in the literature. However, comparisons between devices and their interoperability have not been thoroughly studied. This paper tries to fill this gap by proposing procedures to improve the interoperability among different hand biometric schemes. The experiments were conducted on a database made up of 8,320 hand images acquired from six different hand biometric schemes, including a flat scanner, webcams at different wavelengths, high quality cameras, and contactless devices. Acquisitions on both sides of the hand were included. Our experiment includes four feature extraction methods which determine the best performance among the different scenarios for two of the most popular hand biometrics: hand shape and palm print. We propose smoothing techniques at the image and feature levels to reduce interdevice variability. Results suggest that comparative hand shape offers better performance in terms of interoperability than palm prints, but palm prints can be more effective when using similar sensors.

  10. On the Feasibility of Interoperable Schemes in Hand Biometrics

    PubMed Central

    Morales, Aythami; González, Ester; Ferrer, Miguel A.

    2012-01-01

    Personal recognition through hand-based biometrics has attracted the interest of many researchers in the last twenty years. A significant number of proposals based on different procedures and acquisition devices have been published in the literature. However, comparisons between devices and their interoperability have not been thoroughly studied. This paper tries to fill this gap by proposing procedures to improve the interoperability among different hand biometric schemes. The experiments were conducted on a database made up of 8,320 hand images acquired from six different hand biometric schemes, including a flat scanner, webcams at different wavelengths, high quality cameras, and contactless devices. Acquisitions on both sides of the hand were included. Our experiment includes four feature extraction methods which determine the best performance among the different scenarios for two of the most popular hand biometrics: hand shape and palm print. We propose smoothing techniques at the image and feature levels to reduce interdevice variability. Results suggest that comparative hand shape offers better performance in terms of interoperability than palm prints, but palm prints can be more effective when using similar sensors. PMID:22438714

  11. Effect of Hand Antisepsis Agent Selection and Population Characteristics on Surgical Site Infection Pathogens.

    PubMed

    Oriel, Brad S; Chen, Qi; Wong, Kevin; Itani, Kamal M F

    Selection of a pre-operative hand antisepsis agent has not been studied in relation to surgical site infection (SSI) culture data. In our hospital, we introduced an alcohol-based hand rub (ABR) in 2012 as an alternative to traditional aqueous surgical scrubs (TSS). It was the goal of this study to review any effect of this implementation on SSI pathogen characteristics. In addition, we sought to compare our SSI culture data with available National Healthcare Safety Network (NHSN) data. We hypothesized that SSI pathogens and resistant isolates are affected by surgical hand antisepsis technique. Data collected prospectively between 2007 and 2014 were retrospectively analyzed for two time periods at the Veterans Affairs Boston Healthcare System (VABHS): Before ABR implementation (TSS group) and after (ABR group). Pathogen distribution and pathogenic isolate resistance profiles were compared for TSS and ABR, and similar comparisons, along with procedure-associated SSI comparisons, were made between VABHS and NHSN. All VABHS data were interpreted and categorized according to NHSN definitions. Compared with TSS (n = 4,051), ABR (n = 2,293) had a greater rate of Staphylococcus aureus (42.6% vs. 38.0%), Escherichia coli (12.8% vs. 9.9%), Pseudomonas aeruginosa (8.5% vs. 2.8%), and Enterobacter spp. (10.6% vs. 2.8%), and a lower rate of Klebsiella pneumoniae/K. oxytoca (4.3% vs. 8.5%) cultured from superficial and deep SSIs (p < 0.05). Of the S. aureus isolates, 35.0% and 44.4% were resistant to oxacillin/methicillin (MRSA) in ABR and TSS, respectively (p = 0.06). Looking at all SSIs, coagulase-negative staphylococci and K. pneumoniae/K. oxytoca at VABHS (4.0% and 10.4%, respectively) accounted for the biggest difference from NHSN (11.7% and 4.0%, respectively). Aside from MRSA, where there was no difference between VABHS and NHSN (42.9% vs. 43.7%, respectively; p = 0.87), statistically significant (p < 0.05) differences were observed among multi

  12. Mentor's hand hygiene practices influence student's hand hygiene rates.

    PubMed

    Snow, Michelle; White, George L; Alder, Stephen C; Stanford, Joseph B

    2006-02-01

    There were 3 objectives for this prospective quasiexperimental study. The first was to determine the effect of mentor's hand hygiene practices on student's hand hygiene rates during clinical rotations. The second was to assess the difference in hand hygiene rates for students with and without prior medical experience. The third was to assess the student's opinion and beliefs regarding hand hygiene. Sixty students enrolled in a certified nursing program were selected to participate in the study. Each study group was observed twice during the 30-day span. The first observational period was conducted on day 1 of clinical rotation. The second observational period was conducted on day 30 of clinical rotation. Students were observed for hand hygiene. Also assessed were medical experience, sex, gloving, age, and mentor's hand hygiene practices. After observational period 2, a brief questionnaire was given to students to determine their opinion and beliefs regarding hand hygiene. The questionnaire was divided into 5 sections: student's commitment to hand hygiene, their perception of hand hygiene inconvenience, the necessity of hand hygiene, the student's ability to perform hand hygiene, and their opinion on the frequency of medical staff's hand hygiene. The mentor's practice of hand hygiene was the strongest predictor of the student's rate of hand hygiene for both observational periods (P < .01). Furthermore, students without prior medical experience had a significant increase in hand hygiene rates when comparing observational period 1 to observational period 2 (P < .01). Glove usage was associated with increased hand hygiene rates by 50% during observational period 1 (P = .01) and 44% during observational period 2 (P < .01). Male students during observational period 1 practiced hand hygiene 30% less often than female students (P < .01); however, during observational period 2, there was no significant difference between hand hygiene rates for males and females (P = .82

  13. Medicare and Medicaid programs; fire safety requirements for certain health care facilities; amendment. Final rule.

    PubMed

    2006-09-22

    This final rule adopts the substance of the April 15, 2004 tentative interim amendment (TIA) 00-1 (101), Alcohol Based Hand Rub Solutions, an amendment to the 2000 edition of the Life Safety Code, published by the National Fire Protection Association (NFPA). This amendment allows certain health care facilities to place alcohol-based hand rub dispensers in egress corridors under specified conditions. This final rule also requires that nursing facilities at least install battery-operated single station smoke alarms in resident rooms and common areas if they are not fully sprinklered or they do not have system-based smoke detectors in those areas. Finally, this final rule confirms as final the provisions of the March 25, 2005 interim final rule with changes and responds to public comments on that rule.

  14. Using postural synergies to animate a low-dimensional hand avatar in haptic simulation.

    PubMed

    Mulatto, Sara; Formaglio, Alessandro; Malvezzi, Monica; Prattichizzo, Domenico

    2013-01-01

    A technique to animate a realistic hand avatar with 20 DoFs based on the biomechanics of the human hand is presented. The animation does not use any sensor glove or advanced tracker with markers. The proposed approach is based on the knowledge of a set of kinematic constraints on the model of the hand, referred to as postural synergies, which allows to represent the hand posture using a number of variables lower than the number of joints of the hand model. This low-dimensional set of parameters is estimated from direct measurement of the motion of thumb and index finger tracked using two haptic devices. A kinematic inversion algorithm has been developed, which takes synergies into account and estimates the kinematic configuration of the whole hand, i.e., also of the fingers whose end tips are not directly tracked by the two haptic devices. The hand skin is deformable and its deformation is computed using a linear vertex blending technique. The proposed synergy-based animation of the hand avatar involves only algebraic computations and is suitable for real-time implementation as required in haptics.

  15. Effectiveness of Liquid Soap and Hand Sanitizer against Norwalk Virus on Contaminated Hands▿

    PubMed Central

    Liu, Pengbo; Yuen, Yvonne; Hsiao, Hui-Mien; Jaykus, Lee-Ann; Moe, Christine

    2010-01-01

    Disinfection is an essential measure for interrupting human norovirus (HuNoV) transmission, but it is difficult to evaluate the efficacy of disinfectants due to the absence of a practicable cell culture system for these viruses. The purpose of this study was to screen sodium hypochlorite and ethanol for efficacy against Norwalk virus (NV) and expand the studies to evaluate the efficacy of antibacterial liquid soap and alcohol-based hand sanitizer for the inactivation of NV on human finger pads. Samples were tested by real-time reverse transcription-quantitative PCR (RT-qPCR) both with and without a prior RNase treatment. In suspension assay, sodium hypochlorite concentrations of ≥160 ppm effectively eliminated RT-qPCR detection signal, while ethanol, regardless of concentration, was relatively ineffective, giving at most a 0.5 log10 reduction in genomic copies of NV cDNA. Using the American Society for Testing and Materials (ASTM) standard finger pad method and a modification thereof (with rubbing), we observed the greatest reduction in genomic copies of NV cDNA with the antibacterial liquid soap treatment (0.67 to 1.20 log10 reduction) and water rinse only (0.58 to 1.58 log10 reduction). The alcohol-based hand sanitizer was relatively ineffective, reducing the genomic copies of NV cDNA by only 0.14 to 0.34 log10 compared to baseline. Although the concentrations of genomic copies of NV cDNA were consistently lower on finger pad eluates pretreated with RNase compared to those without prior RNase treatment, these differences were not statistically significant. Despite the promise of alcohol-based sanitizers for the control of pathogen transmission, they may be relatively ineffective against the HuNoV, reinforcing the need to develop and evaluate new products against this important group of viruses. PMID:19933337

  16. Hand and power tools: A compilation

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Some hand and power tools were described. Section One describes several tools and shop techniques that may be useful in the home or commercial shop. Section Two contains descriptions of tools that are particularly applicable to industrial work, and in Section Three a number of metal working tools are presented.

  17. Automated Hand-Held UXO Detection, Classification & Discrimination Sensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bell, Thomas H.

    2000-06-12

    The research focused on procedures for target discrimination and classification using hand-held EMI sensors. The idea is to have a small, portable sensor that can be operated in a sweep or similar pattern in front of the operator, and that is capable of distinguishing between buried UXO and clutter on the spot. Curing Phase 1, we developed the processing techniques for distinguishing between buried UXO and clutter using the EM61-HH hand-held metal detector.

  18. Creating Virtual-hand and Virtual-face Illusions to Investigate Self-representation

    PubMed Central

    Ma, Ke; Lippelt, Dominique P.; Hommel, Bernhard

    2017-01-01

    Studies investigating how people represent themselves and their own body often use variants of "ownership illusions", such as the traditional rubber-hand illusion or the more recently discovered enfacement illusion. However, these examples require rather artificial experimental setups, in which the artificial effector needs to be stroked in synchrony with the participants' real hand or face—a situation in which participants have no control over the stroking or the movements of their real or artificial effector. Here, we describe a technique to establish ownership illusions in a setup that is more realistic, more intuitive, and of presumably higher ecological validity. It allows creating the virtual-hand illusion by having participants control the movements of a virtual hand presented on a screen or in virtual space in front of them. If the virtual hand moves in synchrony with the participants' own real hand, they tend to perceive the virtual hand as part of their own body. The technique also creates the virtual-face illusion by having participants control the movements of a virtual face in front of them, again with the effect that they tend to perceive the face as their own if it moves in synchrony with their real face. Studying the circumstances that illusions of this sort can be created, increased, or reduced provides important information about how people create and maintain representations of themselves. PMID:28287602

  19. Hand tools: A compilation

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A selection of new hand tools, modifications of existing tools, and techniques developed in the course of NASA research and development projects are presented. The items are presented in two sections: tools for cable and connector applications, and tools for welding applications. Safety is emphasized, together with ease of operation and use in restricted areas or hazardous environments. The discussions are directed primarily toward the technician engaged in assembly or maintenance of mechanical or electrical equipment.

  20. 46 CFR 160.048-6 - Marking.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... waterproof so that after 72 hours submergence in water, it will withstand vigorous rubbing by hand while wet.... Inspected and tested in accordance with U.S. Coast Guard regulations. Dry out thoroughly when wet. (Kapok or...

  1. 46 CFR 160.048-6 - Marking.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... waterproof so that after 72 hours submergence in water, it will withstand vigorous rubbing by hand while wet.... Inspected and tested in accordance with U.S. Coast Guard regulations. Dry out thoroughly when wet. (Kapok or...

  2. 46 CFR 160.048-6 - Marking.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... waterproof so that after 72 hours submergence in water, it will withstand vigorous rubbing by hand while wet.... Inspected and tested in accordance with U.S. Coast Guard regulations. Dry out thoroughly when wet. (Kapok or...

  3. 46 CFR 160.048-6 - Marking.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... waterproof so that after 72 hours submergence in water, it will withstand vigorous rubbing by hand while wet.... Inspected and tested in accordance with U.S. Coast Guard regulations. Dry out thoroughly when wet. (Kapok or...

  4. Friction and wear of several compressor gas-path seal movements

    NASA Technical Reports Server (NTRS)

    Bill, R. C.; Wisander, D. W.

    1978-01-01

    Rub interaction experiments were conducted on a series of sintered and plasma sprayed compressor gas path seal materials in contact with Ti-6Al-4V blade tip and knife edge rotors. The most rub tolerant materials investigated were sintered Nichrome and plasma sprayed nickel 25 percent graphite. The effectiveness of providing a compliant substrate for dense seal material coatings was also demonstrated. In general, it was observed that rotor wear and high frictional energy generation rates accompanied smearing or surface densification of the materials investigated. The onset of smearing was sensitive to rub interaction parameters and seal geometry. Two complementary models were proposed to account for the smearing trends. One is based on thermal effects, the other on particulate escape effects. They were shown to be consistent with the experimental evidence at hand, and together they predict that smearing, with the onset of high energy rub conditions, is favored when incursion rates (radial motion) are low, incursion depths are high, the seal geometry is of a knife-edge character, and the seal particle size is small.

  5. Hand preference and skilled hand performance among individuals with successful rightward conversions of the writing hand.

    PubMed

    Porac, Clare

    2009-03-01

    Searleman and Porac (2001) studied lateral preference patterns among successfully switched left-hand writers, left-hand writers with no switch pressure history, and left-hand writers who did not switch when pressured. They concluded that left-handers who successfully shift to right-hand writing are following an inherent right-sided lateralisation pattern that they already possess. Searleman and Porac suggested that the neural mechanisms that control lateralisation in the successfully switched individuals are systematically different from those of other groups of left-handers. I examined patterns of skilled and less-skilled hand preference and skilled hand performance in a sample of 394 adults (ages 18-94 years). The sample contained successfully switched left-hand writers, left-handers pressured to shift who remained left-hand writers, left-handers who did not experience shift pressures, and right-handers. Both skilled hand preference and skilled hand performance were shifted towards the right side in successfully switched left-hand writers. This group also displayed mixed patterns of hand preference and skilled hand performance in that they were not as right-sided as "natural" right-handers nor were they as left-sided as the two left-hand writing groups, which did not differ from each other. The experience of being pressured to switch to right-hand writing was not sufficient to shift lateralisation patterns; the pressures must be experienced in the context of an underlying neural control mechanism that is amenable to change as a result of these external influences.

  6. Multimodality approach to classifying hand utilization for the clinical breast examination.

    PubMed

    Laufer, Shlomi; Cohen, Elaine R; Maag, Anne-Lise D; Kwan, Calvin; Vanveen, Barry; Pugh, Carla M

    2014-01-01

    The clinical breast examination (CBE) is performed to detect breast pathology. However, little is known regarding clinical technique and how it relates to diagnostic accuracy. We sought to quantify breast examination search patterns and hand utilization with a new data collection and analysis system. Participants performed the CBE while the sensor mapping and video camera system collected performance data. From this data, algorithms were developed that measured the number of hands used during the exam and active examination time. This system is a feasible and reliable method to collect new information on CBE techniques.

  7. Comparative Evaluation of Smear Layer and Debris on the Canal Walls prepared with a Combination of Hand and Rotary ProTaper Technique using Scanning Electron Microscope.

    PubMed

    Kiran, S; Prakash, Sandeep; Siddharth, Pujari R; Saha, Supradip; Geojan, Naiza E; Ramachandran, Mookambika

    2016-07-01

    The effect of smear layer and debris on the success rate of endodontic treatment has not yet been definitely determined. So the present study was aimed to evaluate the amount of smear layer and debris on the canal walls prepared with a combination of hand and rotary ProTaper technique using NaOCl and ethylenediaminetetraacetic acid (EDTA) alternately as root canal irrigants using scanning electron microscope (SEM). Eighty intact freshly extracted human permanent mandibular premolar teeth were collected and randomly divided equally into four groups. In group I canals were prepared with hand K-Flexofiles; group II with rotary ProTaper instruments; group III with rotary ProTaper instruments and final instrumentation was done with hand K-Flexofile; group IV with rotary ProTaper instruments and final instrumentation was done with RC-Prep and irrigated with 1 mL of normal saline. In all groups canals were irrigated using NaOCl and EDTA alternately. After instrumentation, the teeth were prepared for SEM examination using five-score indices for debris and smear layer at coronal, middle, and apical third levels. Statistical analysis was performed using chi-square test (p < 0.05) and Kruskal-Wallis test (p < 0.05). Statistically significant difference was observed between the groups in cleaning the apical third. Groups I and III showed better canal cleanliness compared to group II. The use of EDTA and NaOCl in group III was more effective in removing debris and smear layer compared to EDTA and normal saline in group IV. Regardless of the instrumentation technique employed and the irrigant used, the cleaning ability decreased in the apical third, resulting in higher debris and smear layer scores compared to coronal and middle third levels. None of the instrumentation techniques in the present study could completely eliminate the smear layer and debris from the canal walls. Instrumentation of the canals with hand files after automated rotary preparation could result in cleaner

  8. Use of hands-free technique among operating room nurses in the Republic of Korea.

    PubMed

    Jeong, Ihn Sook; Park, Sunmi

    2009-03-01

    The recently introduced concept of hands-free technique (HFT) currently has no recommendations or formal educational program for use in the Republic of Korea. This study evaluated the level of HFT use and investigated factors related to HFT use among Korean operating room nurses. Data were obtained through a self-administered questionnaire from 158 operating room nurses in 7 general hospitals in Busan, Republic of Korea, in April and May 2006. The questionnaire elicited information on demographics, exposure to education on HFT, attitude toward the need for HFT, concerns about exposure to bloodborne pathogens, and experience with HTF use. Multilevel multiple logistic regression analysis with generalized estimating equations was used, and adjusted odds ratios (ORs) and their 95% confidence intervals (CIs) were calculated. We found that 56% of the participants had used HFT, and 50% had received education on HFT. The use of HFT had a significant association with both education on HFT (OR = 12.02; 95% CI = 7.50 to 19.25) and attitude toward the need for HFT (OR = 4.22; 95% CI = 2.43 to 7.35). Increasing education about HFT could be the most important approach to increasing the use of HFT among Korean operating room nurses. Thus, routine teaching about HFT should be provided to these nurses.

  9. [Does the hand solely belong in the hands of a qualified hand surgeon?

    PubMed

    Güven, Asim; Kols, Kerstin; Fischer, Klaus; Schönberger, Michael; Allert, Sixtus

    2017-09-01

    Background In Germany, Hand Surgery is an additional qualification that can only be obtained by a three-year training after a completed residency in General Surgery, Plastic Surgery or Trauma and Orthopaedic Surgery. Nevertheless, injuries and diseases of the hand are also treated by physicians without this particular qualification. It is questionable whether these treatments more often lead to medical malpractice. Material and Methods 376 charges of medical malpractice in surgical treatments of the hand and forearm that were closed in 2014 and 2015 were collected by the Arbitration Board for Medical Liability Issues of the Medical Association of North Germany.Cases with proven medical malpractice were classified by the qualification of the physician in charge and analysed. A statistical analysis was performed with the use of the program SPSS (IBM). Results Medical malpractice was proven in 42 of 113 cases with an attending physician who held the additional qualification for Hand Surgery (37.2 %). For physicians without this qualification, the figures were 79 out of 155 (51.0 %) in the group of trauma and orthopaedic surgeons and 54 out of 108 (50.0 %) in the group of general surgeons. The differences between the hand surgeons and the trauma and orthopaedic surgeons (p = 0.017) and between hand surgeons and general surgeons were significant (p = 0.037). Conclusions It was shown that physicians with an additional qualification in hand surgery had signifcantly fewer proven medical malpratice cases than physicians without this qualification. The following trends were observed in the cases of the physicians without the additional qualification in hand surgery: underestimation of the severity of trauma to soft tissues and infections of the hand, errors in the surgical examination of the hand, including functional tests of tendons and nerves, as well as in diagnostic findings after X-ray studies of the hand. Georg Thieme Verlag KG Stuttgart · New York.

  10. TMS stimulus-response asymmetry in left- and right-handed individuals.

    PubMed

    Daligadu, Julian; Murphy, Bernadette; Brown, Jeff; Rae, Brendan; Yielder, Paul

    2013-02-01

    There have been inconsistencies in the literature regarding asymmetrical neural control and results of experiments using TMS techniques. Therefore, the aim of this study was to further our understanding of the neural relationships that may underlie performance asymmetry with respect to the distal muscles of the hand using a TMS stimulus-response curve technique. Twenty-four male subjects (12 right handed, 12 left handed) participated in a TMS stimulus-response (S-R) curve trial. Focal TMS was applied over the motor cortex to find the optimal position for the first dorsal interossei muscle and to determine rest threshold (RTh). Seven TMS intensities ranging from 90 to 150 % of RTh were delivered in 10 % increments. One single TMS block consisted of 16 stimuli at each intensity. Peak-to-peak amplitudes were measured and the S-R curve generated. In right-handed subjects, the mean difference in slopes between the right and left hand was -0.011 ± 0.03, while the mean difference between hands in left-handed subjects was -0.049 ± 0.08. Left-handed normalized data in right handers displayed a mean of 1.616 ± 1.019 (two-tailed t test p < 0.05). The left-handed group showed a significant change in the normalized slope as indicated by a mean of 1.693 ± 0.149 (two-tailed t test p < 0.00006). The results found in this study reinforce previous work which suggests that there is an asymmetry in neural drive that exists in both left- and right-handed individuals. However, the results show that the non-dominant motor hemisphere displays a greater amount of excitability than the dominant, which goes against the conventional dogma. This asymmetry indicates that the non-dominant hemisphere may have a higher level of excitation or a lower level of inhibition for both groups of participants.

  11. [Bertha Röntgen or the transparency of the hand].

    PubMed

    Picard, J D

    1996-01-01

    It is to Wilhelm Conrad Röntgen, the first elected "radiologist" of our Academy and the first Nobel Prize winner in physics, that we owe the transparency of the hand. We celebrate today the centenary of the great scientific discovery which was to revolutionize the diagnosis, and thereby the treatment, of a large number of illnesses the discovery of X-rays. It would be unjust not to link the name of this scientist with that of his wife, Bertha, who, ignorant of the dangers of all "novel medical inventions" volunteered her own hand for his research experiments: the hand which was to bring to the world tangible proof of this remarkable discovery. To a lesser degree, but nonetheless essential, we acknowledge, albeit not in exhaustive detail, all the progress made by the work of pioneers using this new investigative technique. So let us now return to the hand:--a body part which it was easy to immobilize, remembering that in those days a single radiographic exposure took up to an hour to obtain,--we will consider the immortalised hand of Bertha Röntgen,---to whom this address is dedicated,---and its radiographic exposures which allow us to appreciate the advances and to perceive the limitations of this technique. They also enable us better to envisage future investigative approaches whereby a deeper knowledge of the human body may be acquired. We note that compared with the histopathological sciences, imaging is not specific. Numerous microscopic structures, in particular neurological and vascular ones, are still insufficiently well visualised and the transmission pathways between the hand and the central nervous system deserve better characterisation. Current, research programmes are attempting to overcome these limitation of modern imaging. All the experience gained in studying the transparency of the hand, as we have discussed, is applicable to every part of the human anatomy. To credit: Röntgen's discovery with all its originality, we could say that the hand was

  12. 46 CFR 160.060-8 - Marking.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... waterproof so that after 72 hours submergence in water it will withstand vigorous rubbing by hand while wet... of (151/2 lb., 11 lb., or 7 lb.). Dry out thoroughly when wet. Approved for use on all recreational...

  13. What's growing on your stethoscope? (And what you can do about it).

    PubMed

    Schroeder, Ariel; Schroeder, Maryellen A; D'Amico, Frank

    2009-08-01

    Studies have shown that rubbing alcohol pads on stethoscope diaphragms can reduce bacterial colonization, but alcohol pads are used infrequently used and not always available. We conducted a prospective, single-blinded study to investigate whether simultaneously scrubbing hands and stethoscope head with alcohol-based hand foam would significantly reduce bacterial counts on the stethoscope. Using their own stethoscope, participants imprinted the stethoscope head onto a chocolate agar plate, then used alcohol-based hand foam to cleanse their hands while simultaneously rubbing the stethoscope head. Once the stethoscope heads were dry, the participants imprinted their stethoscope heads onto a second plate. After 48 hours' incubation, we determined the bacterial counts for the prewash and post-wash plates, and compared the 2. We analyzed a total of 184 cultures (from 92 stethoscopes). Both the mean (28 prewash vs 3 post-wash, P=.001) and median (11 prewash vs 1 post-wash, P=.001) colony counts were significantly greater before being cleansed. Three methicillin-resistant Staphylococcus aureus (MRSA) colonies were identified in the prewash period; all were destroyed by the foam. The estimated number of hand washes needed to prevent 1 MRSA colony is 31 (95% confidence interval [CI], 18-89). Simultaneously using hand foam to clean hands and stethoscope heads reduces bacterial counts on stethoscopes. Further research is needed to determine whether this intervention can reduce morbidity and mortality associated with bacterial infection.

  14. [Hand Therapy in the Treatment of Patients with CRPS].

    PubMed

    Körbler, C; Pfau, M; Becker, F; Koester, U; Werdin, F

    2015-06-01

    In the modern treatment of CRPS a multidisciplinary concept is firmly established (MMPT, multimodal pain therapy). Besides medical therapy and psychotherapy, physio- and occupational therapy count as basic treatment options. Although physio- and occupational therapy (in the following called hand therapy) are the most important basic treatments, the therapy is hardly standardised and there are few scientific investigations concerning their application. Therefore the purpose of this paper is to present the applied hand therapeutic techniques with regard to function/performance, application and effectiveness, and to derive a suitable treatment algorithm. The techniques used in hand therapy are presented and reviewed in regard to their effectiveness by means of a literature search. It turns out that exercise therapy, manual therapy, graded motor imaging, CO2 baths and occupational therapy have a proven benefit for the patients. Although for many of the treatments reliable evidence-based data are lacking a treatment algorithm was established but there is a strong need for further investigations concerning the therapeutic effectiveness in the treatment of CRPS. © Georg Thieme Verlag KG Stuttgart · New York.

  15. The Influence of Temperature on the Frictional Behavior of Duplex-Coated Die Steel Rubbing Against Forging Brass

    NASA Astrophysics Data System (ADS)

    Ebrahimzadeh, I.; Ashrafizadeh, F.

    2015-01-01

    Improvement of die life under hot forging of brass alloys is considered vital from both economical and technical points of view. One of the best methods for improving die life is duplex coatings. In this research, the influence of temperature on the tribological behavior of duplex-coated die steel rubbing against forging brass was investigated. The wear tests were performed on a pin-on-disk machine from room temperature to 700 °C; the pins were made in H13 hot work tool steel treated by plasma nitriding and by PVD coatings of TiN-TiAlN-CrAlN. The disks were machined from a two-phase brass alloy too. The results revealed that the friction coefficient of this tribosystem went through a maximum at 550 °C and decreased largely at 700 °C. Furthermore, the formation of Cr2O3 caused the reduction of friction coefficient at 700 °C. PVD coatings proved their wear resistance up to 550 °C, well above the working temperature of the brass forging dies.

  16. Noise reduction techniques in the design of a pneumatic-driven hand held power tool

    NASA Astrophysics Data System (ADS)

    Skinner, Christian M.

    2005-09-01

    Pneumatic-driven hand-held power tools generate noise in the workplace. Current legislation in Europe and the USA aims at protecting workers against noise exposure. In the United States, the Occupational Safety and Health Administration (OSHA) requires that employers create a hearing conservation program if the noise exposure exceeds 85 dB(A). In the European Community under the Directive 2003/10/EC, employers are required to provide hearing protection if the noise exposure within the working environment exceeds 80 dB(A) and must require hearing protection to be worn if the noise exposure exceeds 85 dB(A). This paper examines the sources of noise which contribute to the overall noise from a hand-held power tool. A test plan was developed to identify these individual sources of noise and to determine if structure-borne noise or airborne noise is the dominant source relative to the overall noise level. The measurements were performed per International Standards Organization (ISO) 15744. This paper will describe the methodology used to identify the noise sources and reduce the overall noise of a hand-held power tool.

  17. Protaper--hybrid technique.

    PubMed

    Simon, Stephane; Lumley, Philip; Tomson, Phillip; Pertot, Wilhelm-Joseph; Machtou, Pierre

    2008-03-01

    Crown down preparation is the most known and described technique since the introduction of Nickel Titanium (NiTi) rotary instruments in endodontics. This technique gives good results but has limitations, such as not addressing the initial anatomy of oval or dumb-bell shaped canals. The specific design of the Protaper instruments allows use of them with a different technique and, specifically, with a brushing motion in the body of the canal. The recent introduction of hand Protaper files has expanded the range of application of this system, especially in curved canals. The 'hybrid technique', using rotary and hand files, and the advantages of the combination of both instruments, are clearly described in this article. Used with this technique, the Protaper is a very safe system to use, and more controllable, for both inexperienced and experienced practitioners alike, than other systems. To understand the precautions needed with rotary files, and how to use them to preserve the anatomy of the canal and get a tapered shaping, even in severely curved canals.

  18. Surgical hand preparation with chlorhexidine soap or povidone iodine: new methods to increase immediate and residual effectiveness, and provide a safe alternative to alcohol solutions.

    PubMed

    Herruzo, R; Vizcaino, M J; Yela, R

    2018-04-01

    Surgical use of 4% chlorhexidine soap (CHX-4) and 10% povidone iodine (PVP-I-10) does not meet the standards defined by EN 12791. To investigate the possibility of increasing the immediate and residual effects of these antiseptics. Over three consecutive weeks, n-propanol, standard CHX-4 and PVP-I-10 were tested in two experimental groups of volunteers. The new method for applying the antiseptic substances involved standard hand rub and rinse of CHX-4 or PVP-I-10, followed by application of an aqueous solution based on 5% chlorhexidine or PVP-I-10 with no further rinsing of the hands prior to donning gloves. Samples were taken to assess immediate and residual effects, analysing the logarithmic reduction of colony-forming units. At t=0 h, n-propanol was superior in bactericidal effect to standard CHX-4 (P<0.05), but the new chlorhexidine protocol was superior to both standard CHX-4 (P<0.01) and n-propanol (P<0.05); the same effect was observed at t=3 h (residual effect). At t=0 h, n-propanol was significantly superior to standard PVP-I-10, but the new PVP-I-10 protocol was superior, although not significantly, to n-propanol. There was no significant residual effect at t=3 h. The new protocol for chlorhexidine application permits surgical hand preparation with chlorhexidine, as a safe alternative to alcohol solutions, because it meets the standards defined by EN 12791. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  19. Exploration of Hand Grasp Patterns Elicitable Through Non-Invasive Proximal Nerve Stimulation.

    PubMed

    Shin, Henry; Watkins, Zach; Hu, Xiaogang

    2017-11-29

    Various neurological conditions, such as stroke or spinal cord injury, result in an impaired control of the hand. One method of restoring this impairment is through functional electrical stimulation (FES). However, traditional FES techniques often lead to quick fatigue and unnatural ballistic movements. In this study, we sought to explore the capabilities of a non-invasive proximal nerve stimulation technique in eliciting various hand grasp patterns. The ulnar and median nerves proximal to the elbow joint were activated transcutanously using a programmable stimulator, and the resultant finger flexion joint angles were recorded using a motion capture system. The individual finger motions averaged across the three joints were analyzed using a cluster analysis, in order to classify the different hand grasp patterns. With low current intensity (<5 mA and 100 µs pulse width) stimulation, our results show that all of our subjects demonstrated a variety of consistent hand grasp patterns including single finger movement and coordinated multi-finger movements. This study provides initial evidence on the feasibility of a proximal nerve stimulation technique in controlling a variety of finger movements and grasp patterns. Our approach could also be developed into a rehabilitative/assistive tool that can result in flexible movements of the fingers.

  20. Electromyography data for non-invasive naturally-controlled robotic hand prostheses

    PubMed Central

    Atzori, Manfredo; Gijsberts, Arjan; Castellini, Claudio; Caputo, Barbara; Hager, Anne-Gabrielle Mittaz; Elsig, Simone; Giatsidis, Giorgio; Bassetto, Franco; Müller, Henning

    2014-01-01

    Recent advances in rehabilitation robotics suggest that it may be possible for hand-amputated subjects to recover at least a significant part of the lost hand functionality. The control of robotic prosthetic hands using non-invasive techniques is still a challenge in real life: myoelectric prostheses give limited control capabilities, the control is often unnatural and must be learned through long training times. Meanwhile, scientific literature results are promising but they are still far from fulfilling real-life needs. This work aims to close this gap by allowing worldwide research groups to develop and test movement recognition and force control algorithms on a benchmark scientific database. The database is targeted at studying the relationship between surface electromyography, hand kinematics and hand forces, with the final goal of developing non-invasive, naturally controlled, robotic hand prostheses. The validation section verifies that the data are similar to data acquired in real-life conditions, and that recognition of different hand tasks by applying state-of-the-art signal features and machine-learning algorithms is possible. PMID:25977804

  1. Proper Hand-Washing Techniques in Public Restrooms: Differences in Gender, Race, Signage, and Time of Day

    ERIC Educational Resources Information Center

    Kinnison, Andrea; Cottrell, Randal R.; King, Keith A.

    2004-01-01

    The purpose of this study was to evaluate hand washing behaviors in public restrooms with and without reminder signs. Gender, race, signage, and time of day were examined to determine if there were differences in hand washing compliance based on these variables. Participants included male and female adults entering restrooms at two public shopping…

  2. Significance of palpable tendon friction rubs in early diffuse cutaneous systemic sclerosis.

    PubMed

    Doré, Adam; Lucas, Mary; Ivanco, Dana; Medsger, Thomas A; Domsic, Robyn T

    2013-08-01

    Palpable tendon friction rubs (TFRs) in systemic sclerosis (SSc; scleroderma) have been associated with diffuse skin thickening, increased disability, and poor survival. Our objective was to quantify the prognostic implications of palpable TFRs on the development of disease complications and longer-term mortality in an incident cohort of early diffuse cutaneous SSc (dcSSc) patients. We identified early dcSSc patients (disease duration <2 years from the first SSc symptom) first evaluated at the University of Pittsburgh Scleroderma Center between 1980 and 2006 and found to have palpable TFRs. These patients were matched 1:1 with the next consecutive early dcSSc patient without TFRs as a control. All had ≥2 clinic visits and 5 years of followup from the first visit. A total of 287 early dcSSc patients with TFR were identified and matched to 287 controls. The median disease duration was 0.83 years in TFR patients and 1.04 years in controls. The median followup was 10.1 years in TFR patients and 7.9 years in controls. Over the course of their illness, patients with TFRs had a >2-fold risk of developing renal crisis and cardiac and gastrointestinal disease complications, even after adjustment for other known risk factors. Patients with TFRs had poorer 5- and 10-year survival rates. Patients with early dcSSc having ≥1 TFRs are at an increased risk of developing renal, cardiac, and gastrointestinal involvement before and after their first Scleroderma Center visit and have reduced survival. Patients presenting with TFRs should be carefully monitored for serious internal organ involvement. Copyright © 2013 by the American College of Rheumatology.

  3. Ultrasonography of the hand, wrist, and elbow.

    PubMed

    Bodor, Marko; Fullerton, Brad

    2010-08-01

    High-frequency diagnostic ultrasonography of the hand, wrist and elbow has significant potential to improve the quality of diagnosis and care provided by neuromuscular and musculoskeletal specialists. In patients referred for weakness, pain and numbness of the hand, wrist or elbow, diagnostic ultrasonography can be an adjunct to electrodiagnosis and help in identifying ruptured tendons and treating conditions such as carpal tunnel syndrome or trigger finger. Use of a small high-frequency (>10-15 MHz) transducer, an instrument with a blunt pointed tip to enhance sonopalpation and a model of the hand, wrist and elbow is advised to enhance visualization of small anatomical structures and complex bony contours. A range of conditions, including tendon and ligament ruptures, trigger finger, de Quervain tenosynovitis, intersection syndrome, lateral epicondylitis, and osteoarthritis, is described along with detailed ultrasonography-guided injection techniques for carpal tunnel syndrome and trigger finger. Copyright 2010 Elsevier Inc. All rights reserved.

  4. Effective Propulsion in Swimming: Grasping the Hydrodynamics of Hand and Arm Movements.

    PubMed

    van Houwelingen, Josje; Schreven, Sander; Smeets, Jeroen B J; Clercx, Herman J H; Beek, Peter J

    2017-02-01

    In this paper, a literature review is presented regarding the hydrodynamic effects of different hand and arm movements during swimming with the aim to identify lacunae in current methods and knowledge, and to distil practical guidelines for coaches and swimmers seeking to increase swimming speed. Experimental and numerical studies are discussed, examining the effects of hand orientation, thumb position, finger spread, sculling movements, and hand accelerations during swimming, as well as unsteady properties of vortices due to changes in hand orientation. Collectively, the findings indicate that swimming speed may be increased by avoiding excessive sculling movements and by spreading the fingers slightly. In addition, it appears that accelerating the hands rather than moving them at constant speed may be beneficial, and that (in front crawl swimming) the thumb should be abducted during entry, catch, and upsweep, and adducted during the pull phase. Further experimental and numerical research is required to confirm these suggestions and to elucidate their hydrodynamic underpinnings and identify optimal propulsion techniques. To this end, it is necessary that the dynamical motion and resulting unsteady effects are accounted for, and that flow visualization techniques, force measurements, and simulations are combined in studying those effects.

  5. Upper limb kinetic analysis of three sitting pivot wheelchair transfer techniques.

    PubMed

    Koontz, Alicia M; Kankipati, Padmaja; Lin, Yen-Sheng; Cooper, Rory A; Boninger, Michael L

    2011-11-01

    The objective of this study was to investigate differences in shoulder, elbow and hand kinetics while performing three different SPTs that varied in terms of hand and trunk positioning. Fourteen unimpaired individuals (8 male and 6 female) performed three variations of sitting pivot transfers in a random order from a wheelchair to a level tub bench. Two transfers involved a forward flexed trunk (head-hips technique) and the third with the trunk remaining upright. The two transfers involving a head hips technique were performed with two different leading hand initial positions. Motion analysis equipment recorded upper body movements and force sensors recorded hand reaction forces. Shoulder and elbow joint and hand kinetics were computed for the lift phase of the transfer. Transferring using either of the head hips techniques compared to the trunk upright style of transferring resulted in reduced superior forces at the shoulder (P<0.002), elbow (P<0.004) and hand (P<0.013). There was a significant increase in the medial forces in the leading elbow (P=0.049) for both head hip transfers and the trailing hand for the head hip technique with the arm further away from the body (P<0.028). The head hip techniques resulted in higher shoulder external rotation, flexion and extension moments compared to the trunk upright technique (P<0.021). Varying the hand placement and trunk positioning during transfers changes the load distribution across all upper limb joints. The results of this study may be useful for determining a technique that helps preserve upper limb function overtime. Published by Elsevier Ltd.

  6. Hand Matters: Left-Hand Gestures Enhance Metaphor Explanation

    ERIC Educational Resources Information Center

    Argyriou, Paraskevi; Mohr, Christine; Kita, Sotaro

    2017-01-01

    Research suggests that speech-accompanying gestures influence cognitive processes, but it is not clear whether the gestural benefit is specific to the gesturing hand. Two experiments tested the "(right/left) hand-specificity" hypothesis for self-oriented functions of gestures: gestures with a particular hand enhance cognitive processes…

  7. Comparison of the antimicrobial efficacy of povidone-iodine, povidone-iodine-ethanol and chlorhexidine gluconate-ethanol surgical scrubs.

    PubMed

    Nishimura, Chieko

    2006-01-01

    Scrubbing of the hands and forearms with a brush and antiseptic agents has been the standard for surgical practice. However, it has been increasingly recognized that brush scrubbing may provoke side effects and that an alcohol-based hand antiseptic used in conjunction with a scrub agent enhances the effectiveness. In this study, two types of alcohol-based agents were used after a povidone-iodine (PVP-I) scrub and compared for their effectiveness. The study was conducted as a crossover trial with 20 volunteers. After hand rubbing with PVP-I, either PVP-I-ethanol rubbing or chlorhexidine gluconate-ethanol (CHG-ethanol) rubbing was used for surgical hand cleansing. Samples were collected by the modified glove juice method to count bacteria on hands. In both groups, the bacterial count was significantly reduced after handwashing (p < 0.001), and the reduction was still significant after 2 h (p < 0.001 for PVP-I-ethanol and p < 0.002 for CHG-ethanol). The log(10) reduction factor (RF) in the PVP-I-ethanol group was significantly higher than that in the CHG-ethanol group immediately after handwashing (p < 0.001) but significantly lowered after 2 h (p < 0.01) to the level similar to that of CHG-ethanol. Although RF was lower in the CHG-ethanol group immediately after and 2 h after handwashing compared to the PVP-I-ethanol group, it did not decrease with time. Brushless surgical scrubbing with PVP-I-ethanol or CHG-ethanol in conjunction with PVP-I showed antiseptic effects immediately after and 2 h after handwashing. RF immediately after handwashing was significantly higher with PVP-I-ethanol compared to CHG-ethanol, but it was similar in both groups after 2 h. These results suggest that when used in combination with a PVP-I scrub, an alcohol-based hand antiseptic containing the same active agent (PVP-I in this study) has a powerful antiseptic effect; however, when it contains different antiseptic agents (i.e. CHG in this study), it should be selected carefully based on

  8. [Hand osteoarthritis].

    PubMed

    Šenolt, Ladislav

    Hand osteoarthritis (OA) is a common chronic disorder causing pain and limitation of mobility of affected joints. The prevalence of hand OA increases with age and more often affects females. Clinical signs obviously do not correlate with radiographic findings - symptomatic hand OA affects approximately 26 % of adult subjects, but radiographic changes can be found in up to two thirds of females and half of males older than 55 years.Disease course differ among individual patients. Hand OA is a heterogeneous disease. Nodal hand OA is the most common subtype affecting interphalangeal joints, thumb base OA affects first carpometacarpal joint. Erosive OA represents a specific subtype of hand OA, which is associated with joint inflammation, more pain, functional limitation and erosive findings on radiographs.Treatment of OA is limited. Analgesics and nonsteroidal anti-inflammatory drugs are the only agents reducing symptoms. New insights into the pathogenesis of disease should contribute to the development of novel effective treatment of hand OA.

  9. Stiff Hands

    MedlinePlus

    ... Stiff Hands Find a hand surgeon near you. Videos Figures Figure 1: Hand splint to help straighten ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  10. Hand Fractures

    MedlinePlus

    ... Hand Fractures Find a hand surgeon near you. Videos Hand Fractures Close Popup Figures Figure 1 - Examples ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  11. On the road to a neuroprosthetic hand: a novel hand grasp orthosis based on functional electrical stimulation.

    PubMed

    Leeb, Robert; Gubler, Miguel; Tavella, Michele; Miller, Heather; Del Millan, Jose R

    2010-01-01

    To patients who have lost the functionality of their hands as a result of a severe spinal cord injury or brain stroke, the development of new techniques for grasping is indispensable for reintegration and independency in daily life. Functional Electrical Stimulation (FES) of residual muscles can reproduce the most dominant grasping tasks and can be initialized by brain signals. However, due to the very complex hand anatomy and current limitations in FES-technology with surface electrodes, these grasp patterns cannot be smoothly executed. In this paper, we present an adaptable passive hand orthosis which is capable of producing natural and smooth movements when coupled with FES. It evenly synchronizes the grasping movements and applied forces on all fingers, allowing for naturalistic gestures and functional grasps of everyday objects. The orthosis is also equipped with a lock, which allows it to remain in the desired position without the need for long-term stimulation. Furthermore, we quantify improvements offered by the orthosis compare them with natural grasps on healthy subjects.

  12. Exposure of the surgeon's hands to radiation during hand surgery procedures.

    PubMed

    Żyluk, Andrzej; Puchalski, Piotr; Szlosser, Zbigniew; Dec, Paweł; Chrąchol, Joanna

    2014-01-01

    The objective of the study was to assess the time of exposure of the surgeon's hands to radiation and calculate of the equivalent dose absorbed during surgery of hand and wrist fractures with C-arm fluoroscope guidance. The necessary data specified by the objective of the study were acquired from operations of 287 patients with fractures of fingers, metacarpals, wrist bones and distal radius. 218 operations (78%) were percutaneous procedures and 60 (22%) were performed by open method. Data on the time of exposure and dose of radiation were acquired from the display of the fluoroscope, where they were automatically generated. These data were assigned to the individual patient, type of fracture, method of surgery and the operating surgeon. Fixations of distal radial fractures required longer times of radiation exposure (mean 61 sec.) than fractures of the wrist/metacarpals and fingers (38 and 32 sec., respectively), which was associated with absorption of significantly higher equivalent doses. Fixations of distal radial fractures by open method were associated with statistically significantly higher equivalent doses (0.41 mSv) than percutaneous procedures (0.3 mSv). Fixations of wrist and metacarpal bone fractures by open method were associated with lower equivalent doses (0.34 mSv) than percutaneous procedures (0.37 mSv),but the difference was not significant. Fixations of finger fractures by open method were associated with lower equivalent doses (0.13 mSv) than percutaneous procedures (0.24 mSv), the difference being statistically non-significant. Statistically significant differences in exposure time and equivalent doses were noted between 4 surgeons participating in the study, but no definitive relationship was found between these parameters and surgeons' employment time. 1. Hand surgery procedures under fluoroscopic guidance are associated with mild exposure of the surgeons' hands to radiation. 2. The equivalent dose was related to the type of fracture

  13. Tendon 'turnover lengthening' technique.

    PubMed

    Cerovac, S; Miranda, B H

    2013-11-01

    Tendon defect reconstruction is amongst the most technically challenging areas in hand surgery. Tendon substance deficiency reconstruction techniques include lengthening, grafting, two-stage reconstruction and tendon transfers, however each is associated with unique challenges over and above direct repair. We describe a novel 'turnover lengthening' technique for hand tendons that has successfully been applied to the repair of several cases, including a case of attritional flexor and traumatic extensor tendon rupture in two presented patients where primary tenorrhaphy was not possible. In both cases a good post-operative outcome was achieved, as the patients were happy having returned back to normal activities of daily living such that they were discharged 12 weeks post-operatively. Our technique avoids the additional morbidity and complications associated with grafting, transfers and two stage reconstructions. It is quick, simple and reproducible for defects not exceeding 3-4 cm, provides a means of immediate one stage reconstruction, no secondary donor site morbidity and does not compromise salvage by tendon transfer and/or two-stage reconstruction in cases of failure. To our knowledge no such technique has been previously been described to reconstruct such hand tendon defects. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  14. Health care worker hand hygiene in the pediatric special care unit at Mulago National Referral Hospital in Uganda: a best practice implementation project.

    PubMed

    Muhumuza, Christine; Gomersall, Judith Streak; Fredrick, Makumbi E; Atuyambe, Lynn; Okiira, Christopher; Mukose, Aggrey; Ssempebwa, John

    2015-03-01

    The hands of a health care worker are a common vehicle of pathogen transmission in hospital settings. Health care worker hand hygiene is therefore critical for patients' well being. Whilst failure of health care workers to comply with the best hand hygiene practice is a problem in all health care settings, issues of lack of access to adequate cleaning equipment and in some cases even running water make practicing good hand hygiene particularly difficult in low-resource developing country settings. This study reports an audit and feedback project that focused on the hand hygiene of the health care worker in the pediatric special care unit of the Mulago National Referral Hospital, which is a low-resource setting in Uganda. To improve hand hygiene among health care workers in the pediatric special care unit and thereby contribute to reducing transmission of health care worker-associated pathogens. The Joanna Briggs Institute three-phase Practical Application of Clinical Evidence System audit and feedback tool for promoting evidence utilization and change in health care was used. In phase one of the project, stakeholders were engaged and seven evidence-based audit criteria were developed. A baseline audit was then conducted. In phase two, barriers underpinning areas of noncompliance found in the baseline audit were identified and three strategies - education, reminders and provision of hand cleaning equipment - were implemented to overcome them. In phase three, a follow-up audit was conducted. Compliance with best practice hygiene was found to be poor in the baseline audit for all but one of the audit criteria. Following the implementation of the strategies, hand hygiene improved. The compliance rate increased substantially across all criteria. Staff education achieved 100%, whilst criterion 4 increased to 70%. However, use of alcohol-based hand-rub for hand hygiene only improved to 66%, and for six of the seven audit criteria, compliance remained below 74%. The

  15. Hand Washing

    MedlinePlus

    ... study, only 58% of female and 48% of male middle- and high-school students washed their hands after using the bathroom. Yuck! How to Wash Your Hands Correctly There's a right way to wash your hands. Follow these simple ...

  16. Hand-Eye Calibration in Visually-Guided Robot Grinding.

    PubMed

    Li, Wen-Long; Xie, He; Zhang, Gang; Yan, Si-Jie; Yin, Zhou-Ping

    2016-11-01

    Visually-guided robot grinding is a novel and promising automation technique for blade manufacturing. One common problem encountered in robot grinding is hand-eye calibration, which establishes the pose relationship between the end effector (hand) and the scanning sensor (eye). This paper proposes a new calibration approach for robot belt grinding. The main contribution of this paper is its consideration of both joint parameter errors and pose parameter errors in a hand-eye calibration equation. The objective function of the hand-eye calibration is built and solved, from which 30 compensated values (corresponding to 24 joint parameters and six pose parameters) are easily calculated in a closed solution. The proposed approach is economic and simple because only a criterion sphere is used to calculate the calibration parameters, avoiding the need for an expensive and complicated tracking process using a laser tracker. The effectiveness of this method is verified using a calibration experiment and a blade grinding experiment. The code used in this approach is attached in the Appendix.

  17. Using virtual data for training deep model for hand gesture recognition

    NASA Astrophysics Data System (ADS)

    Nikolaev, E. I.; Dvoryaninov, P. V.; Lensky, Y. Y.; Drozdovsky, N. S.

    2018-05-01

    Deep learning has shown real promise for the classification efficiency for hand gesture recognition problems. In this paper, the authors present experimental results for a deeply-trained model for hand gesture recognition through the use of hand images. The authors have trained two deep convolutional neural networks. The first architecture produces the hand position as a 2D-vector by input hand image. The second one predicts the hand gesture class for the input image. The first proposed architecture produces state of the art results with an accuracy rate of 89% and the second architecture with split input produces accuracy rate of 85.2%. In this paper, the authors also propose using virtual data for training a supervised deep model. Such technique is aimed to avoid using original labelled images in the training process. The interest of this method in data preparation is motivated by the need to overcome one of the main challenges of deep supervised learning: using a copious amount of labelled data during training.

  18. Evolution of the human hand: approaches to acquiring, analysing and interpreting the anatomical evidence

    PubMed Central

    MARZKE, MARY W.; MARZKE, R. F.

    2000-01-01

    The discovery of fossil hand bones from an early human ancestor at Olduvai Gorge in 1960, at the same level as primitive stone tools, generated a debate about the role of tools in the evolution of the human hand that has raged to the present day. Could the Olduvai hand have made the tools? Did the human hand evolve as an adaptation to tool making and tool use? The debate has been fueled by anatomical studies comparing living and fossil human and nonhuman primate hands, and by experimental observations. These have assessed the relative abilities of apes and humans to manufacture the Oldowan tools, but consensus has been hampered by disagreements about how to translate experimental data from living species into quantitative models for predicting the performance of fossil hands. Such models are now beginning to take shape as new techniques are applied to the capture, management and analysis of data on kinetic and kinematic variables ranging from hand joint structure, muscle mechanics, and the distribution and density of bone to joint movements and muscle recruitment during manipulative behaviour. The systematic comparative studies are highlighting a functional complex of features in the human hand facilitating a distinctive repertoire of grips that are apparently more effective for stone tool making than grips characterising various nonhuman primate species. The new techniques are identifying skeletal variables whose form may provide clues to the potential of fossil hominid hands for one-handed firm precision grips and fine precision manoeuvering movements, both of which are essential for habitual and effective tool making and tool use. PMID:10999274

  19. Inspections of hand washing supplies and hand sanitizer in public schools.

    PubMed

    Ramos, Mary M; Blea, Mary; Trujillo, Rebecca; Greenberg, Cynthia

    2010-10-01

    Hand washing and hand antisepsis are proven infection control measures in the school setting, yet barriers such as lack of soap, paper towels, and hand sanitizer can hinder compliance. This pilot study measured the prevalence of hand cleaning supplies in public schools. Ten school districts (93 schools) participated in school nurse inspections. In November 2008, 90 schools (97%) reported their inspection results. Among 697 total bathrooms, 88.8% had soap and 91.7% had paper towels or hand dryers. Hand sanitizer was reported in 1.2% of bathrooms and 15.2% of cafeterias. No difference was observed between boys' and girls' bathrooms, or primary and secondary schools, in the prevalence of soap or paper towels/hand dryers. Hand washing supplies were generally available in public school bathrooms. Alcohol-based hand sanitizer in school bathrooms was reported occasionally and should be discouraged. Hand sanitizer in a supervised setting, the school cafeteria, was not often reported and should be promoted.

  20. Moisturizing alcohol hand gels for surgical hand preparation.

    PubMed

    Jones, R D; Jampani, H; Mulberry, G; Rizer, R L

    2000-03-01

    With the use of novel formulary technology, unique moisturizing hand gels have been developed that offer significant advantages in perioperative and other health care settings. These advantages include the time-saving capabilities of a waterless formulation, the persistence and effectiveness of a surgical scrub, and the moisturization and protective properties of a lotion. Extensive laboratory and clinical studies, involving in vivo antimicrobial activity against resident and transient flora, skin moisturization on normal and dry skin, and compatibility with latex gloves, have supported these advantages. Nondrying alcohol hand gels can be used for antiseptic hand washing, hand scrubs between procedures (i.e., reentry scrubs), brushless surgical scrubs, moisturizers, and glove-donning aids.

  1. [Microsurgical 2nd toe transfer for catastrophic hand reconstruction].

    PubMed

    Placer, A; Lozano, Ja

    2007-01-01

    The correct reconstruction of the catastrophic hand requires complex surgical techniques. The microsurgical transference of a toe is indicated when all other reconstructive options are shown to be useless for the reconstruction of the required clamp function. In this clinical note we set out the case of a 32 year old man, who came to our accident and emergency department after suffering a traffic accident. After exploration the diagnosis was that of catastrophic left hand, among other policontusions. Urgent surgery was carried out, saving the maximum possible viable structures. The immediate result of this surgery was a hand with 1st, 4th and 5th functional fingers. As the essential clamp function between the 1st and 4th or 5th fingers was not totally satisfactory, we decided to reconstruct the 3rd finger of his hand with his ipsilateral 2nd toe. All pertinent studies to determine vascularisation of the flap were carried out in planning the surgery, and the microsurgical transfer was then realized, which was successful. Today, after a suitable rehabilitation, the patient has recovered a satisfactory function of heavy and fine clamp in the operated hand. Toe to hand transfer is a good option for finger reconstruction and its function. Rehabilitation is the key to functional recovery.

  2. Ground reaction force characteristics of Tai Chi push hand.

    PubMed

    Chang, Yao-Ting; Chang, Jia-Hao; Huang, Chen-Fu

    2014-01-01

    Push Hand is an advanced training technique for the Yang-style old frame 108 forms Tai Chi Chuan. It is performed by two practitioners. To clarify how people use forces during Push Hand training, it is important to review the ground reaction force (GRF). Here, we quantify the characteristics of the GRF during Push Hand training. Kinematic data and GRF data from 10 Tai Chi Chuan practitioners (29.9 ± 7.87 years) were synchronously recorded using a three-dimensional motion analysis system (200 frames · s(-1)) and three-dimensional force plates (1000 Hz). The resultant GRF for both feet for the 0%, 50% and 100% phases of attack and defence were compared to body weight using a paired-samples t-test. The differences in the resultant GRF between the 0%, 50% and 100% phases of attack and defence were tested by one-way repeated-measures ANOVA. The significance level was set to 0.05. The total resultant GRF was almost equal to the participant's body weight in push hand. This result was consistent throughout the entire push hand process. Our results revealed that the GRF was comparable to the body weight, implying that practitioners do not push or resist their opponents during the push hand process.

  3. Virtual Reality Glasses and "Eye-Hands Blind Technique" for Microsurgical Training in Neurosurgery.

    PubMed

    Choque-Velasquez, Joham; Colasanti, Roberto; Collan, Juhani; Kinnunen, Riina; Rezai Jahromi, Behnam; Hernesniemi, Juha

    2018-04-01

    Microsurgical skills and eye-hand coordination need continuous training to be developed and refined. However, well-equipped microsurgical laboratories are not so widespread as their setup is expensive. Herein, we present a novel microsurgical training system that requires a high-resolution personal computer screen, smartphones, and virtual reality glasses. A smartphone placed on a holder at a height of about 15-20 cm from the surgical target field is used as the webcam of the computer. A specific software is used to duplicate the video camera image. The video may be transferred from the computer to another smartphone, which may be connected to virtual reality glasses. Using the previously described training model, we progressively performed more and more complex microsurgical exercises. It did not take long to set up our system, thus saving time for the training sessions. Our proposed training model may represent an affordable and efficient system to improve eye-hand coordination and dexterity in using not only the operating microscope but also endoscopes and exoscopes. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Initial experience with visualizing hand and foot tendons by dual-energy computed tomography.

    PubMed

    Deng, Kai; Sun, Cong; Liu, Cheng; Ma, Rui

    2009-01-01

    To assess the feasibility of visualizing hand and foot tendons by dual-energy computed tomography (CT). Twenty patients who suffered from hand or feet pains were scanned on dual-source CT (Definition, Forchheim, Germany) with dual-energy mode at tube voltages of 140 and 80 kV and a corresponding ratio of 1:4 between tube currents. The reconstructed images were postprocessed by volume rendering techniques (VRT) and multiplanar reconstruction (MPR). All of the suspected lesions were confirmed by surgery or follow-up studies. Twelve patients (total of 24 hands and feet, respectively) were found to be normal and the other eight patients (total of nine hands and feet, respectively) were found abnormal. Dual-energy techniques are very useful in visualizing tendons of the hands and feet, such as flexor pollicis longus tendon, flexor digitorum superficialis/profundus tendon, Achilles tendon, extensor hallucis longus tendon, and extensor digitorum longus tendon, etc. It can depict the whole shape of the tendons and their fixation points clearly. Peroneus longus tendon in the sole of the foot was not displayed very well. The distal ends of metacarpophalangeal joints with extensor digitoium tendon and extensor pollicis longus tendon were poorly shown. The lesions of tendons such as the circuitry, thickening, and adherence were also shown clearly. Dual-energy CT offers a new method to visualize tendons of the hand and foot. It could clearly display both anatomical structures and pathologic changes of hand and foot tendons.

  5. Conceptual design of an astronaut hand anthropometry device

    NASA Technical Reports Server (NTRS)

    Mcmahan, Robert

    1993-01-01

    In a microgravity environment, fluid equalizes throughout the body, causing the upper body to swell. This causes the hands to swell which can cause problems for astronauts trying to do work in pressurized EVA (extravehicular activity) gloves. To better design these gloves, accurate measurements of the astronauts swollen hands are needed. Five concepts were developed in this report from an original field of 972 possible concepts. These five concepts were based on mold impression, ultrasound, laser topography, white light photography, and video imaging. From a decision matrix based on nine weighted criteria, the video imaging technique was found to be the best design to pursue.

  6. [The musician's hand: aspects of music physiology and performing arts medicine].

    PubMed

    Blum, J

    2000-09-01

    Musicians are particularly demanding hand patients. Increased expectancy towards the hand surgeon as well as principle aversion to any kind of operative treatment of the musician's hand impede the relationship between hand surgeon and patient. Knowledge and experience of the specific demands towards the musician's hand--including the background of basics in physiology of music making and instrumental techniques--facilitate history taking, examinations, diagnosing as well as the selection of therapy. Besides tendinitis and tendovaginitis, pathologies of the musician's hand are not more frequent compared to the entire population. Still several pathologies reach a significantly pronounced importance through the specific professional requirements. This is true especially for peripheral nerve compression syndromes, arthritis, ganglia, contractures, joint laxity and focal dystonias. The treatment of these disorders and hand trauma require, besides an utmost of hand surgical care, creativity and the implementation of the professional musical surroundings in therapy and rehabilitation, including also the musical instruments. The indication for surgery might be restrained in certain cases, although there are, without doubt, situations, when a professional musician should be operated on at an early stage. This should enhance a rapid return to play the musical instrument and to exercise delicate and demanding skilled movement patterns of his hand.

  7. The Influence of Speed and Grade on Wheelchair Propulsion Hand Pattern

    PubMed Central

    Slowik, Jonathan S.; Requejo, Philip S.; Mulroy, Sara J.; Neptune, Richard R.

    2015-01-01

    Background The hand pattern used during manual wheelchair propulsion (i.e., full-cycle hand path) can provide insight into an individual's propulsion technique. However, previous analyses of hand patterns have been limited by their focus on a single propulsion condition and reliance on subjective qualitative characterization methods. The purpose of this study was to develop a set of objective quantitative parameters to characterize hand patterns and determine the influence of propulsion speed and grade of incline on the patterns preferred by manual wheelchair users. Methods Kinematic and kinetic data were collected from 170 experienced manual wheelchair users on an ergometer during three conditions: level propulsion at their self-selected speed, level propulsion at their fastest comfortable speed, and graded propulsion (8%) at their level self-selected speed. Hand patterns were quantified using a set of objective parameters and differences across conditions were identified. Findings Increased propulsion speed resulted in a shift away from under-rim hand patterns. Increased grade of incline resulted in the hand remaining near the handrim throughout the cycle. Interpretation Manual wheelchair users change their hand pattern based on task-specific constraints and goals. Further work is needed to investigate how differences between hand patterns influence upper extremity demand and potentially lead to the development of overuse injuries and pain. PMID:26228706

  8. Effect of tetramethylsilane flow on the deposition and tribological behaviors of silicon doped diamond-like carbon rubbed against poly(oxymethylene)

    NASA Astrophysics Data System (ADS)

    Deng, Xingrui; Lim, Yankuang; Kousaka, Hiroyuki; Tokoroyama, Takayuki; Umehara, Noritsugu

    2014-11-01

    In this study, silicon doped diamond-like carbon (Si-DLC) was deposited on stainless steel (JIS SUS304) by using surface wave-excited plasma (SWP). The effects of tetramethylsilane (TMS) flow on the composition, topography, mechanical properties and tribological behavior were investigated. Pin-on-disc tribo-meter was used to investigate the tribological behavior of the Si-DLC coating rubbed against poly(oxymethylene) (POM). The results show that the deposition rate, roughness of Si-DLC increased and the hardness of Si-DLC decreased with the increase of TMS flow rate from 2 to 4 sccm; the roughness increase therein led to the increase of ploughing term of friction. The increase of adhesion term was also seen with the increase of TMS flow rate, being attributed to the decrease of hydrogen concentration in the coating. It was considered that more POM transferred onto the Si-DLC deposited at higher TMS flow rate due to larger heat generation by friction.

  9. Hand preference for sending mobile-phone text messages: associations with sex, writing hand, and throwing hand.

    PubMed

    Lambert, Anthony; Hallett, Charlene

    2009-07-01

    Hand preference for sending mobile-phone text messages ("texting") and its relationship with hand preference for other activities were investigated in a questionnaire study with 886 participants. Overall rates of both sinistrality and dextrality were reduced for texting, in comparison with other activities, due to the substantial number of individuals who use both hands simultaneously when performing this activity. Because they both involve verbal expression, it was hypothesised that the association between hand preferences for texting and writing might be stronger than the association between either of these tasks and more spatial activities, such as throwing. This prediction was not confirmed, either in the sample as a whole or in a sub-group of individuals who reported writing and throwing with opposite hands. Females were less likely than males to use their left hand when sending text messages. Implications of these findings are discussed, in relation to theoretical views of handedness and in relation to practical aspects of mobile-phone design.

  10. Hand hygiene practices in a neonatal intensive care unit: a multimodal intervention and impact on nosocomial infection.

    PubMed

    Lam, Barbara C C; Lee, Josephine; Lau, Y L

    2004-11-01

    Health care-associated infections persist as a major problem in most neonatal intensive care units. Hand hygiene has been singled out as the most important measure in preventing hospital-acquired infection. However, hand hygiene compliance among health care workers (HCWs) remains low. The objective of this study was to assess the frequency and nature of patient contacts in neonatal intensive care units and observe the compliance and technique of hand hygiene among HCWs before and after the implementation of a multimodal intervention program. The nature and frequency of patient contacts, the hand hygiene compliance, and hand-washing techniques of HCWs were observed unobtrusively to reflect the baseline compliance and to investigate factors for noncompliance. The intervention consisted of problem-based and task-orientated hand hygiene education, enhancement of minimal handling protocol and clustering of nursing care, liberal provision of alcohol-based hand antiseptic, improvement in hand hygiene facilities, ongoing regular hand hygiene audit, and implementation of health care-associated infection surveillance. The observational study was repeated 6 months after the completion of the intervention program, which extended over 1-year period. Overall hand hygiene compliance increased from 40% to 53% before patient contact and 39% to 59% after patient contact. More marked improvement was observed for high-risk procedures (35%-60%). The average number of patient contacts also decreased from 2.8 to 1.8 per patient per hour. There was improvement in most aspects of hand-washing technique in the postintervention stage. The health care-associated infection rate decreased from 11.3 to 6.2 per 1000 patient-days. A problem-based and task-orientated education program can improve hand hygiene compliance. Enhancement of minimal handling and clustering of nursing procedures reduced the total patient contact episodes, which could help to overcome the major barrier of time constraints

  11. Aromatherapy hand massage for older adults with chronic pain living in long-term care.

    PubMed

    Cino, Kathleen

    2014-12-01

    Older adults living in long-term care experience high rates of chronic pain. Concerns with pharmacologic management have spurred alternative approaches. The purpose of this study was to examine a nursing intervention for older adults with chronic pain. This prospective, randomized control trial compared the effect of aromatherapy M technique hand massage, M technique without aromatherapy, and nurse presence on chronic pain. Chronic pain was measured with the Geriatric Multidimensional Pain and Illness Inventory factors, pain and suffering, life interference, and emotional distress and the Iowa Pain Thermometer, a pain intensity scale. Three groups of 39 to 40 participants recruited from seven long-term care facilities participated twice weekly for 4 weeks. Analysis included multivariate analysis of variance and analysis of variance. Participants experienced decreased levels of chronic pain intensity. Group membership had a significant effect on the Geriatric Multidimensional Pain Inventory Pain and Suffering scores; Iowa Pain Thermometer scores differed significantly within groups. M technique hand massage with or without aromatherapy significantly decreased chronic pain intensity compared to nurse presence visits. M technique hand massage is a safe, simple, but effective intervention. Caregivers using it could improve chronic pain management in this population. © The Author(s) 2014.

  12. Hand biometric recognition based on fused hand geometry and vascular patterns.

    PubMed

    Park, GiTae; Kim, Soowon

    2013-02-28

    A hand biometric authentication method based on measurements of the user's hand geometry and vascular pattern is proposed. To acquire the hand geometry, the thickness of the side view of the hand, the K-curvature with a hand-shaped chain code, the lengths and angles of the finger valleys, and the lengths and profiles of the fingers were used, and for the vascular pattern, the direction-based vascular-pattern extraction method was used, and thus, a new multimodal biometric approach is proposed. The proposed multimodal biometric system uses only one image to extract the feature points. This system can be configured for low-cost devices. Our multimodal biometric-approach hand-geometry (the side view of the hand and the back of hand) and vascular-pattern recognition method performs at the score level. The results of our study showed that the equal error rate of the proposed system was 0.06%.

  13. The Rubber Hand Illusion: Feeling of Ownership and Proprioceptive Drift Do Not Go Hand in Hand

    PubMed Central

    Rohde, Marieke; Di Luca, Massimiliano; Ernst, Marc O.

    2011-01-01

    In the Rubber Hand Illusion, the feeling of ownership of a rubber hand displaced from a participant's real occluded hand is evoked by synchronously stroking both hands with paintbrushes. A change of perceived finger location towards the rubber hand (proprioceptive drift) has been reported to correlate with this illusion. To measure the time course of proprioceptive drift during the Rubber Hand Illusion, we regularly interrupted stroking (performed by robot arms) to measure perceived finger location. Measurements were made by projecting a probe dot into the field of view (using a semi-transparent mirror) and asking participants if the dot is to the left or to the right of their invisible hand (Experiment 1) or to adjust the position of the dot to that of their invisible hand (Experiment 2). We varied both the measurement frequency (every 10 s, 40 s, 120 s) and the mode of stroking (synchronous, asynchronous, just vision). Surprisingly, with frequent measurements, proprioceptive drift occurs not only in the synchronous stroking condition but also in the two control conditions (asynchronous stroking, just vision). Proprioceptive drift in the synchronous stroking condition is never higher than in the just vision condition. Only continuous exposure to asynchronous stroking prevents proprioceptive drift and thus replicates the differences in drift reported in the literature. By contrast, complementary subjective ratings (questionnaire) show that the feeling of ownership requires synchronous stroking and is not present in the asynchronous stroking condition. Thus, subjective ratings and drift are dissociated. We conclude that different mechanisms of multisensory integration are responsible for proprioceptive drift and the feeling of ownership. Proprioceptive drift relies on visuoproprioceptive integration alone, a process that is inhibited by asynchronous stroking, the most common control condition in Rubber Hand Illusion experiments. This dissociation implies that

  14. New discovery of coral rubbings in the north-western Gulf of Kachchh, Gujarat, Western India — GIS based evaluation

    NASA Astrophysics Data System (ADS)

    Sesh Serebiah, J.; Rajkumar, M.; Sun, Jun; Venmathi Maran, B. A.; Saravanakumar, A.; Thivakaran, G. A.

    2011-06-01

    The Gulf of Kachchh in western India, with its arid climate, large semi-diurnal tidal amplitudes, negative water balance and near-pristine water quality, is being extensively developed as oil importing bases for economic reasons in connection with its proximity to the oil exporting countries of the Middle East. Besides, new coral rubbings were sighted in Jakhau, north-western Gulf of Kachchh. Dredging in Mandvi of the north Gulf covering 3.5 km2 revealed a similar assortment of live corals with their associated flora and fauna. These pioneering observations demonstrate that there exist live corals of young polyps-colony of Favia sp. belonging to the family Faviidae in the north-western Gulf of Kachchh. The environmental parameters there were carefully recorded as: surface water temperature (°C) varying from 29 to 31.8, salinity (ppt), pH, dissolved oxygen (mgL-1) and total suspended solids (mgL-1) in the ranges of 37-43.5, 7.7-8.45, 5.4-6.8 and 11-31, respectively.

  15. Fitting a hand-glove prosthesis to enhance the reconstructed mutilated hand.

    PubMed

    Leow, M E; Kour, A K; Pereira, B P; Pho, R W

    1998-03-01

    Microsurgical reconstruction of the severely mutilated hand aimed at improving prehensile functions often does not address the esthetic aspects of the hand. The poor appearance of the reconstructed hand affects its active display and use. A hand-glove prosthesis may be prescribed in this instance to enhance the overall form and function of the mutilated hand. We reviewed 16 cases of mutilating hand injuries in which surgical reconstructions were performed and the patients were subsequently fitted with a hand-glove prosthesis to augment the outcome. An improved appearance was achieved in all patients fitted with the prosthesis. The patients' sense of confidence was also enhanced, which in turn promoted the active and open use of the reconstructed hands. While prescribed primarily to improve the appearance of the reconstructed hands, these prostheses were documented to enhance the physical hand functions in 11 cases by increasing the span of the hand and providing an opposable post and a palmar base for holding and for anchorage. The prosthesis enhanced assistive functions of the reconstructed hands and freed the contralateral normal hand for use in bimanual activities, such as holding a wallet and taking out money, supporting a note pad for writing, and holding a plate at buffet receptions. At the 18-month follow-up visit, 13 (87%) of the patients continued to use their prosthesis. Wear and tear were problems associated with the frequent use of the prosthesis. The expected life span of the prosthesis with daily use ranged from 2 to 3 years. All the patients acknowledged that the prosthesis played a role in their rehabilitation and that it helped them to overcome the initial psychological trauma and to come to terms with their physical loss.

  16. Hand Biometric Recognition Based on Fused Hand Geometry and Vascular Patterns

    PubMed Central

    Park, GiTae; Kim, Soowon

    2013-01-01

    A hand biometric authentication method based on measurements of the user's hand geometry and vascular pattern is proposed. To acquire the hand geometry, the thickness of the side view of the hand, the K-curvature with a hand-shaped chain code, the lengths and angles of the finger valleys, and the lengths and profiles of the fingers were used, and for the vascular pattern, the direction-based vascular-pattern extraction method was used, and thus, a new multimodal biometric approach is proposed. The proposed multimodal biometric system uses only one image to extract the feature points. This system can be configured for low-cost devices. Our multimodal biometric-approach hand-geometry (the side view of the hand and the back of hand) and vascular-pattern recognition method performs at the score level. The results of our study showed that the equal error rate of the proposed system was 0.06%. PMID:23449119

  17. Evaluation of Hand Lay-Up and Resin Transfer Molding in Composite Wind Turbine Blade Manufacturing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    CAIRNS,DOUGLAS S.; SHRAMSTAD,JON D.

    2000-06-01

    The majority of the wind turbine blade industry currently uses low cost hand lay-up manufacturing techniques to process composite blades. While there are benefits to the hand lay-up process, drawbacks inherent to this process along with advantages of other techniques suggest that better manufacturing alternatives may be available. Resin Transfer Molding (RTM) was identified as a processing alternative and shows promise in addressing the shortcomings of hand lay-up. This report details a comparison of the RTM process to hand lay-up of composite wind turbine blade structures. Several lay-up schedules and critical turbine blade structures were chosen for comparison of theirmore » properties resulting from RTM and hand lay-up processing. The geometries investigated were flat plate, thin and thick flanged T-stiffener, I-beam, and root connection joint. It was found that the manufacturing process played an important role in laminate thickness, fiber volume, and weight for the geometries investigated. RTM was found to reduce thickness and weight and increase fiber volumes for all substructures. RTM resulted in tighter material transition radii and eliminated the need for most secondary bonding operations. These results would significantly reduce the weight of wind turbine blades. Hand lay-up was consistently slower in fabrication times for the structures investigated. A comparison of mechanical properties showed no significant differences after employing fiber volume normalization techniques to account for geometry differences resulting from varying fiber volumes. The current root specimen design does not show significant mechanical property differences according to process and exceeds all static and fatigue requirements.« less

  18. Guideline Implementation: Hand Hygiene.

    PubMed

    Goldberg, Judith L

    2017-02-01

    Performing proper hand hygiene and surgical hand antisepsis is essential to reducing the rates of health care-associated infections, including surgical site infections. The updated AORN "Guideline for hand hygiene" provides guidance on hand hygiene and surgical hand antisepsis, the wearing of fingernail polish and artificial nails, proper skin care to prevent dermatitis, the wearing of jewelry, hand hygiene product selection, and quality assurance and performance improvement considerations. This article focuses on key points of the guideline to help perioperative personnel make informed decisions about hand hygiene and surgical hand antisepsis. The key points address the necessity of keeping fingernails and skin healthy, not wearing jewelry on the hands or wrists in the perioperative area, properly performing hand hygiene and surgical hand antisepsis, and involving patients and visitors in hand hygiene initiatives. Perioperative RNs should review the complete guideline for additional information and for guidance when writing and updating policies and procedures. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  19. The influence of speed and grade on wheelchair propulsion hand pattern.

    PubMed

    Slowik, Jonathan S; Requejo, Philip S; Mulroy, Sara J; Neptune, Richard R

    2015-11-01

    The hand pattern used during manual wheelchair propulsion (i.e., full-cycle hand path) can provide insight into an individual's propulsion technique. However, previous analyses of hand patterns have been limited by their focus on a single propulsion condition and reliance on subjective qualitative characterization methods. The purpose of this study was to develop a set of objective quantitative parameters to characterize hand patterns and determine the influence of propulsion speed and grade of incline on the patterns preferred by manual wheelchair users. Kinematic and kinetic data were collected from 170 experienced manual wheelchair users on an ergometer during three conditions: level propulsion at their self-selected speed, level propulsion at their fastest comfortable speed and graded propulsion (8%) at their level self-selected speed. Hand patterns were quantified using a set of objective parameters, and differences across conditions were identified. Increased propulsion speed resulted in a shift away from under-rim hand patterns. Increased grade of incline resulted in the hand remaining near the handrim throughout the cycle. Manual wheelchair users change their hand pattern based on task-specific constraints and goals. Further work is needed to investigate how differences between hand patterns influence upper extremity demand and potentially lead to the development of overuse injuries and pain. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. 42 CFR 403.744 - Condition of participation: Life safety from fire.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... written fire control plans that contain provisions for prompt reporting of fires; extinguishing fires...) The RNHCI must maintain written evidence of regular inspection and approval by State or local fire... contrary, the RNHCI may place alcohol-based hand rub dispensers in its facility if— (i) Use of alcohol...

  1. Inspections of Hand Washing Supplies and Hand Sanitizer in Public Schools

    ERIC Educational Resources Information Center

    Ramos, Mary M.; Blea, Mary; Trujillo, Rebecca; Greenberg, Cynthia

    2010-01-01

    Hand washing and hand antisepsis are proven infection control measures in the school setting, yet barriers such as lack of soap, paper towels, and hand sanitizer can hinder compliance. This pilot study measured the prevalence of hand cleaning supplies in public schools. Ten school districts (93 schools) participated in school nurse inspections. In…

  2. Effect of hand sanitizer location on hand hygiene compliance.

    PubMed

    Cure, Laila; Van Enk, Richard

    2015-09-01

    Hand hygiene is the most important intervention to prevent infection in hospitals. Health care workers should clean their hands at least before and after contact with patients. Hand sanitizer dispensers are important to support hand hygiene because they can be made available throughout hospital units. The aim of this study was to determine whether the usability of sanitizer dispensers correlates with compliance of staff in using the sanitizer in a hospital. This study took place in a Midwest, 404-bed, private, nonprofit community hospital with 15 inpatient care units in addition to several ambulatory units. The usability and standardization of sanitizers in 12 participating inpatient units were evaluated. The hospital measured compliance of staff with hand hygiene as part of their quality improvement program. Data from 2010-2012 were analyzed to measure the relationship between compliance and usability using mixed-effects logistic regression models. The total usability score (P = .0046), visibility (P = .003), and accessibility of the sanitizer on entrance to the patient room (P = .00055) were statistically associated with higher observed compliance rates. Standardization alone showed no significant impact on observed compliance (P = .37). Hand hygiene compliance can be influenced by visibility and accessibility of dispensers. The sanitizer location should be part of multifaceted interventions to improve hand hygiene. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  3. Comparative evaluation of apical extrusion of bacteria using hand and rotary systems : An in vitro study

    PubMed Central

    Ghivari, Sheetal B; Kubasad, Girish C; Deshpande, Preethi

    2012-01-01

    Aim: To evaluate the bacteria extruded apically during root canal preparation using two hand and rotary instrumentation techniques. Materials and Methods: Eighty freshly extracted mandibular premolars were mounted in bacteria collection apparatus. Root canals were contaminated with the pure culture of Enterococcus fecalis (ATCC 29212) and dried at 37°C for 24 h. Bacteria extruded were collected, incubated in brain heart infusion agar for 24 h at 36°C and the colony forming units (CFU) were counted. Statistical Analysis: The mean number of colony forming units were calculated by One-way ANOVA and comparison between the groups made by multiple comparison (Dunnet D) test. Results: The step-back technique extruded highest number of bacteria in comparison to other hand and rotary Ni–Ti systems. Conclusion: Under the limitation of this study all hand and rotary instrumentation techniques extruded bacteria. Among all the instrumentation techniques step-back technique extruded more number of bacteria and K-3 system the least. Further in vivo research in this direction could provide more insight into the biologic factors associated and focus on bacterial species that essentially play a major role in post instrumentation flare-ups. PMID:22368332

  4. Retroperitoneoscopic living donor nephrectomy: initial experience with a unique hand-assisted approach.

    PubMed

    Capolicchio, J-P; Feifer, A; Plante, M K; Tchervenkov, J

    2011-01-01

    The retroperitoneoscopic (RP) approach to live donor nephrectomy (LDN) may be advantageous for the donor because it avoids mobilization of peritoneal organs and provides direct access to the renal vessels. Notwithstanding, this approach is not popular, likely because of the steeper learning curve. We feel that hand-assistance (HA) can reduce the learning curve and in this study, we present our experience with a novel hand-assist approach to retroperitoneoscopic live donor nephrectomy (HARP-LDN). Over a one-yr period, 10 consecutive patients underwent left HARP-LDN with a mean body mass index of 29 and three with prior left abdomen surgery. The surgical technique utilizes a 7 cm, muscle-sparing incision for the hand-port with two endoscopic ports. Operative time was an average of 155 min., with no open conversions. Mean blood loss was 68 mL, and warm ischemia time was 2.5 min. Hospital stay averaged 2.7 d with postoperative complications limited to one urinary retention. Our modified HARP approach to left LDN is safe, effective and can be performed expeditiously. Our promising initial results require a larger patient cohort to confirm the advantages of the hand-assisted retroperitoneal technique. © 2010 John Wiley & Sons A/S.

  5. HandTutor™ enhanced hand rehabilitation after stroke--a pilot study.

    PubMed

    Carmeli, Eli; Peleg, Sara; Bartur, Gadi; Elbo, Enbal; Vatine, Jean-Jacques

    2011-12-01

    This study assessed the potential therapeutic benefi t of using HandTutor™ in combination with traditional rehabilitation in a post-stroke sub-acute population. The study compares an experimental group receiving traditional therapy combined with HandTutorTM treatment, against a control group receiving only traditional therapy. An assessor-blinded, randomized controlled pilot trial, was conducted in the Reuth rehabilitation unit in Israel. Thirty-one stroke patients in the sub-acute phase, were randomly assigned to one of the two groups (experimental or control) in sets of three. The experimental group (n = 16) underwent a hand rehabilitation programme using the HandTutorTM combined with traditional therapy. The control group (n = 15) received only traditional therapy. The treatment schedules for both groups were of similar duration and frequency. Improvements were evaluated using three indicators: 1) The Brunnström-Fugl-Meyer (FM) test, 2) the Box and Blocks (B&B) test and 3) improvement parameters as determined by the HandTutorTM software. Following 15 consecutive treatment sessions, a signifi cant improvement was observed within the experimental group (95% confi dence intervals) compared with the control group: B&B p = 0.015; FM p = 0.041, HandTutor™ performance accuracy on x axis and performance accuracy on y axis p < 0.0003. The results from this pilot study support further investigation of the use of the HandTutorTM in combination with traditional occupational therapy and physiotherapy during post stroke hand function rehabilitation.

  6. Hand motion modeling for psychology analysis in job interview using optical flow-history motion image: OF-HMI

    NASA Astrophysics Data System (ADS)

    Khalifa, Intissar; Ejbali, Ridha; Zaied, Mourad

    2018-04-01

    To survive the competition, companies always think about having the best employees. The selection is depended on the answers to the questions of the interviewer and the behavior of the candidate during the interview session. The study of this behavior is always based on a psychological analysis of the movements accompanying the answers and discussions. Few techniques are proposed until today to analyze automatically candidate's non verbal behavior. This paper is a part of a work psychology recognition system; it concentrates in spontaneous hand gesture which is very significant in interviews according to psychologists. We propose motion history representation of hand based on an hybrid approach that merges optical flow and history motion images. The optical flow technique is used firstly to detect hand motions in each frame of a video sequence. Secondly, we use the history motion images (HMI) to accumulate the output of the optical flow in order to have finally a good representation of the hand`s local movement in a global temporal template.

  7. 46 CFR 160.047-6 - Marking.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... when wet. Do not snag or puncture inner plastic cover. If pads become waterlogged, replace device... buoyant vests shall be sufficiently waterproof so that after 72 hours submergence in water, it will withstand vigorous rubbing by hand while wet without the printed matter becoming illegible. [CGD 72-163R, 38...

  8. Hand Therapy

    MedlinePlus

    ... a scar Find a hand surgeon near you. Videos Figures Figure 1: Examples of hand splints PDF ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  9. Augmented robotic device for EVA hand manoeuvres

    NASA Astrophysics Data System (ADS)

    Matheson, Eloise; Brooker, Graham

    2012-12-01

    During extravehicular activities (EVAs), pressurised space suits can lead to difficulties in performing hand manoeuvres and fatigue. This is often the cause of EVAs being terminated early, or taking longer to complete. Assistive robotic gloves can be used to augment the natural motion of a human hand, meaning work can be carried out more efficiently with less stress to the astronaut. Lightweight and low profile solutions must be found in order for the assistive robotic glove to be easily integrated with a space suit pressure garment. Pneumatic muscle actuators combined with force sensors are one such solution. These actuators are extremely light, yet can output high forces using pressurised gases as the actuation drive. Their movement is omnidirectional, so when combined with a flexible exoskeleton that itself provides a degree of freedom of movement, individual fingers can be controlled during flexion and extension. This setup allows actuators and other hardware to be stored remotely on the user's body, resulting in the least possible mass being supported by the hand. Two prototype gloves have been developed at the University of Sydney; prototype I using a fibreglass exoskeleton to provide flexion force, and prototype II using torsion springs to achieve the same result. The gloves have been designed to increase the ease of human movements, rather than to add unnatural ability to the hand. A state space control algorithm has been developed to ensure that human initiated movements are recognised, and calibration methods have been implemented to accommodate the different characteristics of each wearer's hands. For this calibration technique, it was necessary to take into account the natural tremors of the human hand which may have otherwise initiated unexpected control signals. Prototype I was able to actuate the user's hand in 1 degree of freedom (DOF) from full flexion to partial extension, and prototype II actuated a user's finger in 2 DOF with forces achieved

  10. Nonlinear effects contributing to hand-stopping tones in a horn.

    PubMed

    Ebihara, Takayasu; Yoshikawa, Shigeru

    2013-05-01

    Hand stopping is a technique for playing the French horn while closing the bell relatively tightly using the right hand. The resulting timbre is called "penetrating" and "metallic." The effect of hand stopping on the horn input impedance has been studied, but the tone quality has hardly ever been considered. In the present paper, the dominant physical cause of the stopped-tone quality is discussed in detail. Numerical calculations of the transmission function of the stopped-horn model and the measurements of both sound pressure and wall vibration in hand stopping are carried out. They strongly suggest that the metallicness of the stopped tone is characterized by the generation of higher harmonics extending over 10 kHz due to the rapidly corrugating waveform and that the associated wall vibration on the bell may be responsible for this higher harmonic generation. However, excitation experiments and immobilization experiments performed to elucidate the relationship between sound radiation and wall vibration deny their correlation. Instead, the measurement result of the mouthpiece pressure in hand stopping suggests that minute wave corrugations peculiar to the metallic stopped tones are probably formed by nonlinear sound propagation along the bore.

  11. Laparoscopic radical nephrectomy: incorporating advantages of hand assisted and standard laparoscopy.

    PubMed

    Ponsky, Lee E; Cherullo, Edward E; Banks, Kevin L W; Greenstein, Marc; Streem, Stevan B; Klein, Eric A; Zippe, Craig D

    2003-06-01

    We present an approach to laparoscopic radical nephrectomy and intact specimen extraction, which incorporates hand assisted and standard laparoscopic techniques. A refined approach to laparoscopic radical nephrectomy is described and our experience is reviewed. A low, muscle splitting Gibson incision is made just lateral to the rectus muscle and the hand port is inserted. A trocar is placed through the hand port and pneumoperitoneum is established. With the laparoscope in the hand port trocar 2 additional trocars are placed under direct vision. The laparoscope is then repositioned through the middle trocar and standard laparoscopic instruments are used through the other 2 trocars including the one in the hand port. If at any time during the procedure the surgeon believes the hand would be useful or needed, the trocar is removed from the hand port and the hand is inserted. This approach has been applied to 7 patients. Mean estimated blood loss was 200 cc (range 50 to 300) and mean operative time was 276.7 minutes (range 247 to 360). Mean specimen weight was 767 gm. (range 538 to 1,170). Pathologically 6 specimens were renal cell carcinoma (grades 2 to 4) and 1 was oncocytoma. Mean length of hospital stay was 3.71 days (range 2 to 7). There were no major complications. We believe that this approach enables the surgeon to incorporate the advantages of the hand assisted and standard laparoscopic approaches.

  12. Integration of Scale Invariant Generator Technique and S-A Technique for Characterizing 2-D Patterns for Information Retrieve

    NASA Astrophysics Data System (ADS)

    Cao, L.; Cheng, Q.

    2004-12-01

    The scale invariant generator technique (SIG) and spectrum-area analysis technique (S-A) were developed independently relevant to the concept of the generalized scale invariance (GSI). The former was developed for characterizing the parameters involved in the GSI for characterizing and simulating multifractal measures whereas the latter was for identifying scaling breaks for decomposition of superimposed multifractal measures caused by multiple geophysical processes. A natural integration of these two techniques may yield a new technique to serve two purposes, on the one hand, that can enrich the power of S-A by increasing the interpretability of decomposed patterns in some applications of S-A and, on the other hand, that can provide a mean to test the uniqueness of multifractality of measures which is essential for application of SIG technique in more complicated environment. The implementation of the proposed technique has been done as a Dynamic Link Library (DLL) in Visual C++. The program can be friendly used for method validation and application in different fields.

  13. The evolution of functional hand replacement: From iron prostheses to hand transplantation

    PubMed Central

    Zuo, Kevin J; Olson, Jaret L

    2014-01-01

    The hand is an integral component of the human body, with an incredible spectrum of functionality. In addition to possessing gross and fine motor capabilities essential for physical survival, the hand is fundamental to social conventions, enabling greeting, grooming, artistic expression and syntactical communication. The loss of one or both hands is, thus, a devastating experience, requiring significant psychological support and physical rehabilitation. The majority of hand amputations occur in working-age males, most commonly as a result of work-related trauma or as casualties sustained during combat. For millennia, humans have used state-of-the-art technology to design clever devices to facilitate the reintegration of hand amputees into society. The present article provides a historical overview of the progress in replacing a missing hand, from early iron hands intended primarily for use in battle, to today’s standard body-powered and myoelectric prostheses, to revolutionary advancements in the restoration of sensorimotor control with targeted reinnervation and hand transplantation. PMID:25152647

  14. Bedside ultrasound in the diagnosis of complex hand infections: a case series.

    PubMed

    Marvel, Brett A; Budhram, Gavin R

    2015-01-01

    The red, swollen, infected hand can be a diagnostically challenging presentation in the emergency department (ED). Hand infections are a relatively uncommon ED complaint, and diagnoses may range from simple cellulitis to deep space abscess, and even to suppurative flexor tenosynovitis. The accurate differentiation of these clinical entities is of paramount importance to healing and recovery of function. In this case series, we review 4 patients with similar presenting complaints of a red, swollen hand, but with much different diagnoses and eventual treatment strategies. We describe how ultrasound was used to assist in making the diagnosis and initiating the most appropriate therapy. Finally, we review techniques for sonographic evaluation of the hand and provide imaging tips to improve visualization and accurate diagnosis. Why should an emergency physician be aware of this? Bedside ultrasound may allow for a more rapid and accurate diagnosis of various hand infections when diagnosis by physical examination is unclear. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Prosthetic design directives: Low-cost hands within reach.

    PubMed

    Jones, G K; Rosendo, A; Stopforth, R

    2017-07-01

    Although three million people around the world suffer from the lack of one or both upper limbs 80% of this number is located within developing countries. While prosthetic prices soar with technology 3D printing and low cost electronics present a sensible solution for those that cannot afford expensive prosthetics. The electronic and control design of a low-cost prosthetic hand, the Touch Hand II, is discussed. This paper shows that sensorless techniques can be used to reduce design complexities, costs, and provide easier access to the electronics. A closing and opening finite state machine (COFSM) was developed to handle the actuated digit joint control state and a supervisory switching control scheme, used for speed and grip strength control. Three torque and speed settings were created to be preset for specific grasps. The hand was able to replicate ten frequently used grasps and grip some common objects. Future work is necessary to enable a user to control it with myoelectric signals (MESs) and to solve operational problems related to electromagnetic interference (EMI).

  16. Robot-assisted laparoscopic intracorporeal hand-sewn bowel anastomosis during pediatric bladder reconstructive surgery.

    PubMed

    Gundeti, Mohan S; Wiltz, Aimee L; Zagaja, Gregory P; Shalhav, Arieh L

    2010-08-01

    Bowel anastomosis performed during robot-assisted laparoscopic surgery in both adult and pediatric populations has typically been performed using endoscopic staplers or with exteriorization of the bowel. In the pediatric population, no articles have been published that explore the possibility of a completely intracorporeal hand-sewn anastomosis during robot-assisted laparoscopic surgery. We report our series of six children who were undergoing robot-assisted laparoscopic intracorporeal hand-sewn bowel anastomosis during bladder reconstructive surgery for neurogenic bladder. The postoperative course was uncomplicated with regard to the bowel anastomosis, demonstrating the feasibility of the technique in experienced hands.

  17. A comparison of the relative efficacies of four hand and rotary instrumentation techniques during endodontic retreatment.

    PubMed

    Imura, N; Kato, A S; Hata, G I; Uemura, M; Toda, T; Weine, F

    2000-07-01

    The purpose of this study was to quantify the amount of remaining gutta-percha/scaler on the walls of root canals when two engine-driven instruments (Quantec and ProFile) and two hand instruments (K-file and Hedström file) were used to remove these materials. The amount of apically extruded debris and the time required for treatment were also recorded. One hundred extracted mandibular premolars were prepared using a modified step-back, flare technique and obturated with the lateral condensation technique. After repreparation with the test instruments, the specimens were cut transversally at the cervical, middle and apical thirds with steel discs and the three sections were split longitudinally. The amount of residual debris on the canal walls in each section was examined using a stereomicroscope. In all groups the cervical and middle thirds showed no debris. In the apical third, obturating material was observed in some specimens. No statistically significant difference was found between the two groups for incidence of debris, although the Hedström group showed a greater number of samples with remaining gutta-percha/sealer. When analysing dirty specimens only, there was a statistically significant difference between the four groups (P < 0.01) with the Hedström group having significantly less length of canal wall with remaining obturation material than the Quantec group. There was no significant difference amongst the groups for weight of extruded debris. However, there was a significant difference amongst the groups for mean treatment time with the Hedström file group requiring significantly less time than the Quantec group (P < 0.001); no significant differences were found between the other groups. Six instruments fractured in the Quantec group, four in the ProFile group, two in the Hedström group and two in the K-type group. The results showed that overall, all instruments may leave filling material inside the root canal. During retreatment there is a risk of

  18. Chubby hands or little fingers: sex differences in hand representation.

    PubMed

    Coelho, Lara A; Gonzalez, Claudia L R

    2018-04-03

    Disturbed body representation is a condition defined by the perception that one's body size is different from their anatomical size. While equal amounts of males and females suffer from disturbed body representation, there appear to be differences in the direction of this distortion. Females will typically overestimate, whereas males will typically underestimate body size. One part of the body that has been consistently misperceived is the hands. This misrepresentation consists of two distinct characteristics: an overestimation of hand width, and an underestimation of finger length. Many of these studies, however, have used predominately female participants, allowing for the possibility that women are driving this distortion. The aim of the present study was to examine possible sex differences in hand perception. To this end, participants estimated the location of ten landmarks on their hands when their hands were hidden from view. Our results indicate that females follow the characteristic distortion, whereas males only underestimate finger length (albeit more than females). These findings are surprising, because the hands are not an area of concern for weight gain/loss. We discuss these findings in relation to body dysmorphia literature.

  19. Application of computer image enhancement techniques to shuttle hand-held photography

    NASA Technical Reports Server (NTRS)

    David, B. E.

    1986-01-01

    With the advent of frequent Space Transportation System Shuttle missions, photography from hyperaltitudes stands to become an accessible and convenient resource for scientists and environmental managers. As satellite products (such as LANDSAT) continue to spiral in costs, all but the most affluent consumer is finding Earth imagery from space to be more and more unavailable. Therefore, the potential for Shuttle photography to serve a wide variety of users is increasing. However, despite the popularity of photos from space as public relations tools and report illustrations, little work has been performed to prove their scientific worth beyond that as basic mapping bases. It is the hypothesis of this project that hand-held Earth photography from the Space Shuttle has potentially high scientific merit and that primary data can be extracted. In effect, Shuttle photography should be considered a major remote sensing information resource.

  20. Hand-held digital books in radiology: convenient access to information.

    PubMed

    D'Alessandro, M P; Galvin, J R; Santer, D M; Erkonen, W E

    1995-02-01

    Radiologists need constant, convenient access to current information throughout the course of their daily work. Today most learning in radiology is obtained from the printed word in books, journals, and teaching files, supplemented by the spoken word in lectures and conferences. Although learning from printed material and lectures has been proved efficacious over time, these media share the disadvantage of not being conveniently available for reference during the course of daily work at the alternator or in the examination room when accurate and up-to-date information is needed the most. As a result, many important questions about patient care go unanswered. We have developed a technique--hand-held digital books--to lower this barrier to searching and retrieval. When radiologists have a digital library that can be carried with them, they will be able to incorporate current radiology information into their daily decision making. We describe a technique for creating hand-held digital books and their future use in radiology.

  1. Dextrous robot hands

    NASA Technical Reports Server (NTRS)

    Venkataraman, Subramanian T. (Editor); Iberall, Thea (Editor)

    1990-01-01

    Recent studies of human hand function and their implications for the design of robot hands are discussed in reviews and reports. Topics addressed include human grasp choice and robotic grasp analysis, opposition space and human prehension, coordination in normal and prosthetic reaching, and intelligent exploration by the human hand. Consideration is given to a task-oriented dextrous manipulation architecture, the control architecture for the Belgrade/USC hand, the analysis of multifingered grasping and manipulation, and tactile sensing for shape interpretation. Diagrams, graphs, and photographs are provided.

  2. In a demanding task, three-handed manipulation is preferred to two-handed manipulation

    NASA Astrophysics Data System (ADS)

    Abdi, Elahe; Burdet, Etienne; Bouri, Mohamed; Himidan, Sharifa; Bleuler, Hannes

    2016-02-01

    Equipped with a third hand under their direct control, surgeons may be able to perform certain surgical interventions alone; this would reduce the need for a human assistant and related coordination difficulties. However, does human performance improve with three hands compared to two hands? To evaluate this possibility, we carried out a behavioural study on the performance of naive adults catching objects with three virtual hands controlled by their two hands and right foot. The subjects could successfully control the virtual hands in a few trials. With this control strategy, the workspace of the hands was inversely correlated with the task velocity. The comparison of performance between the three and two hands control revealed no significant difference of success in catching falling objects and in average effort during the tasks. Subjects preferred the three handed control strategy, found it easier, with less physical and mental burden. Although the coordination of the foot with the natural hands increased trial after trial, about two minutes of practice was not sufficient to develop a sense of ownership towards the third arm.

  3. In a demanding task, three-handed manipulation is preferred to two-handed manipulation.

    PubMed

    Abdi, Elahe; Burdet, Etienne; Bouri, Mohamed; Himidan, Sharifa; Bleuler, Hannes

    2016-02-25

    Equipped with a third hand under their direct control, surgeons may be able to perform certain surgical interventions alone; this would reduce the need for a human assistant and related coordination difficulties. However, does human performance improve with three hands compared to two hands? To evaluate this possibility, we carried out a behavioural study on the performance of naive adults catching objects with three virtual hands controlled by their two hands and right foot. The subjects could successfully control the virtual hands in a few trials. With this control strategy, the workspace of the hands was inversely correlated with the task velocity. The comparison of performance between the three and two hands control revealed no significant difference of success in catching falling objects and in average effort during the tasks. Subjects preferred the three handed control strategy, found it easier, with less physical and mental burden. Although the coordination of the foot with the natural hands increased trial after trial, about two minutes of practice was not sufficient to develop a sense of ownership towards the third arm.

  4. 46 CFR 160.049-6 - Marking.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... material provides a minimum buoyant force of 20 lb. Dry out thoroughly when wet. Approved for use on... cushions shall be sufficiently waterproof so that after 72 hours submergence in water, it will withstand vigorous rubbing by hand while wet without the printed matter becoming illegible. [CGFR 65-37, 30 FR 11588...

  5. 46 CFR 160.049-6 - Marking.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... material provides a minimum buoyant force of 20 lb. Dry out thoroughly when wet. Approved for use on... cushions shall be sufficiently waterproof so that after 72 hours submergence in water, it will withstand vigorous rubbing by hand while wet without the printed matter becoming illegible. [CGFR 65-37, 30 FR 11588...

  6. Apparatus Review.

    ERIC Educational Resources Information Center

    Byrum, David L.

    1982-01-01

    Suggests uses for and possible adaptations of a set of semiflexible molecular models. Includes price and supplier information. Also suggests rubbing oil from human face/hands along the pouring lip of a beaker, allowing one to pour uniformly from the beaker spout and making the process as dripless as possible. (Author/JN)

  7. [Comparison of antibacterial effects of different antiseptics after hand washing].

    PubMed

    Buluş, Nesrin; Kaleli, Ilknur

    2004-01-01

    The aim of this study was to compare 4% chlorhexidine gluconate, 7.5% povidone iodine and liquid soap, which are used as hand washing solutions for the immediate, cumulative and residual effects in bacterial growth. For this purpose, 18 volunteers washed their hands with 7.5% povidone iodine, 4% chlorhexidine gluconate and liquid soap by applying standard hygienic hand washing technique. In order to find out the bacterial amount in the hands of study group, glove liquid test was used. For the evaluation of immediate effects, samples were collected just after the washing procedure, for the residual effects samples were collected from gloved hands after 3 hours, and for the cumulative effects, samples were collected after 5 days with daily hand washings. It is found that the immediate effects of 4% chlorhexidine gluconate was superior than others, and 7.5% povidone iodine was superior to liquid soap. There was no difference between 4% chlorhexidine gluconate and 7.5% povidone iodine for residual effects. The cumulative effects were observed for 4% chlorhexidine gluconate and 7.5% povidone iodine, while there was no cumulative effect for liquid soap. According to these results, it can be suggested that 4% chlorhexidine gluconate can be used as a reliable antiseptic agent in the hospitals, especially for laboratories, intensive care units and operating rooms, owing to its favourable immediate, residual and cumulative effects.

  8. Evidence for right-hand feeding biases in a left-handed population.

    PubMed

    Flindall, Jason W; Stone, Kayla D; Gonzalez, Claudia L R

    2015-05-01

    We have recently shown that actions with similar kinematic requirements, but different end-state goals may be supported by distinct neural networks. Specifically, we demonstrated that when right-handed individuals reach-to-grasp food items with intent to eat, they produce smaller maximum grip apertures (MGAs) than when they grasp the same item with intent to place it in a location near the mouth. This effect was restricted to right-handed movements; left-handed movements showed no difference between tasks. The current study investigates whether (and to which side) the effect may be lateralized in left-handed individuals. Twenty-one self-identified left-handed participants grasped food items of three different sizes while grasp kinematics were captured via an Optotrak Certus motion capture array. A main effect of task was identified wherein the grasp-to-eat action generated significantly smaller MGAs than did the grasp-to-place action. Further analysis revealed that similar to the findings in right-handed individuals, this effect was significant only during right-handed movements. Upon further inspection however, we found individual differences in the magnitude and direction of the observed lateralization. These results underscore the evolutionary significance of the grasp-to-eat movement in producing population-level right-handedness in humans as well as highlighting the heterogeneity of the left-handed population.

  9. Hand function in workers with hand-arm vibration syndrome.

    PubMed

    Cederlund, R; Isacsson, A; Lundborg, G

    1999-01-01

    Hand-arm vibration syndrome has been specially addressed in the Scandinavian countries in recent years, but the syndrome is still not sufficiently recognized in many countries. The object of this preliminary study was to describe the nature and character of vibration-induced impairment in the hands of exposed workers. Twenty symptomatic male workers (aged 28 to 65 years) subjected to vibration by hand-held tools were interviewed about subjective symptoms and activities of daily living and were assessed with a battery of objective tests for sensibility, dexterity, grip function, and grip strength. The test results were compared with normative data. The majority of patients complained of cold intolerance, numbness, pain, sensory impairment, and difficulties in handling manual tools and in handwriting. The various objective tests showed considerable variation in indications of pathologic outcome, revealing differences in sensitivity to detect impaired hand function. Semmes-Weinstein monofilament testing for perception of light touch-deep pressure sensation, the small-object shape identification test, and moving two-point discrimination testing for functional sensibility provided the most indications of pathologic outcomes. The authors conclude that vibration-exposed patients present considerable impairment in hand function.

  10. The thermoregulatory function of the human hand: How do palm and digit proportions affect heat loss?

    PubMed

    Payne, Stephanie; Macintosh, Alison; Stock, Jay

    2018-03-30

    The current study assessed whether ecogeographical patterns seen in hand proportions correlate with heat loss directly. Using a brief severe cold immersion experiment on the hand, the influence of hand and digit dimensions on heat loss was evaluated. A sample of 113 living individuals were tested. Two-dimensional and three-dimensional scanning techniques were used to assess hand and digit dimensions. Thermal imaging analysis was used to quantify heat loss during a 3-min ice-water immersion of the hands. When body size was accounted for, hand width and digit length relative to total hand length were significant predictors of heat loss from the hand. The current study provides empirical evidence to support the link between thermodynamic principles relating to surface area-to-volume ratio, and ecogeographical patterns associated with temperature. © 2018 Wiley Periodicals, Inc.

  11. [Application possibilities and initial experience with digital volume tomography in hand and wrist imaging].

    PubMed

    Goerke, Sebastian M; Neubauer, J; Zajonc, H; Thiele, J R; Kotter, E; Langer, M; Stark, G B; Lampert, F M

    2015-02-01

    During the last decade, DVT (digital volume tomography) imaging has become a widely used standard technique in head and neck imaging. Lower radiation exposure compared to conventional computed tomography (MDCT) has been described. Recently, DVT has been developed as an extremity scanner and as such represents a new imaging technique for hand surgery. We here describe the first 24 months experience with this new imaging modality in hand and wrist imaging by presenting representative cases and by describing the technical background. Furthermore, the method's advantages and disadvantages are discussed with reference to the given literature. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Hand in Hand: Media Literacy and Internet Safety

    ERIC Educational Resources Information Center

    Gallagher, Frank

    2011-01-01

    Internet safety cannot be effectively taught without also teaching media literacy. The two go hand in hand, and both are necessary, but neither is sufficient. To understand why, it is important to first appreciate what the real risks to children are. Many of the early Internet safety programs were based on a fear of predators. Predators turned out…

  13. The sterilization of endodontic hand files.

    PubMed

    Hurtt, C A; Rossman, L E

    1996-06-01

    Several different methods of file sterilization were analyzed to determine the best method of providing complete file sterility, including the metal shaft and plastic handle. Six test groups of 15 files were studied using Bacillus stearothermophilus as the test organism. Groups were "sterilized" by glutaraldehyde immersion, steam autoclaving, and various techniques of salt sterilization. Only proper steam autoclaving reliably produced completely sterile instruments. Salt sterilization and glutaraldehyde solutions may not be adequate sterilization methods for endodontic hand files and should not be relied on to provide completely sterile instruments.

  14. Hand Eczema

    PubMed Central

    Agarwal, Uma Shankar; Besarwal, Raj Kumar; Gupta, Rahul; Agarwal, Puneet; Napalia, Sheetal

    2014-01-01

    Hand eczema is often a chronic, multifactorial disease. It is usually related to occupational or routine household activities. Exact etiology of the disease is difficult to determine. It may become severe enough and disabling to many of patients in course of time. An estimated 2-10% of population is likely to develop hand eczema at some point of time during life. It appears to be the most common occupational skin disease, comprising 9-35% of all occupational diseases and up to 80% or more of all occupational contact dermatitis. So, it becomes important to find the exact etiology and classification of the disease and to use the appropriate preventive and treatment measures. Despite its importance in the dermatological practice, very few Indian studies have been done till date to investigate the epidemiological trends, etiology, and treatment options for hand eczema. In this review, we tried to find the etiology, epidemiology, and available treatment modalities for chronic hand eczema patients. PMID:24891648

  15. Skin reactions related to hand hygiene and selection of hand hygiene products.

    PubMed

    Larson, Elaine; Girard, Raphaelle; Pessoa-Silva, Carmem Lucia; Boyce, John; Donaldson, Liam; Pittet, Didier

    2006-12-01

    In October 2004, The World Health Organization (WHO) launched the World Alliance for Patient Safety. Within the alliance, the first priority of the Global Patient Safety Challenge is to reduce health care-associated infection. A key action within the challenge is to promote hand hygiene in health care globally as well as at the country level through the campaign "Clean Care is Safer Care." As a result, the WHO is developing Guidelines on Hand Hygiene in Health Care, designed to be applicable throughout the world. This paper summarizes one component of the global WHO guidelines related to the impact of hand hygiene on the skin of health care personnel, including a discussion of types of skin reactions associated with hand hygiene, methods to reduce adverse reactions, and factors to consider when selecting hand hygiene products. Health care professionals have a higher prevalence of skin irritation than seen in the general population because of the necessity for frequent hand hygiene during patient care. Ways to minimize adverse effects of hand hygiene include selecting less irritating products, using skin moisturizers, and modifying certain hand hygiene practices such as unnecessary washing. Institutions need to consider several factors when selecting hand hygiene products: dermal tolerance and aesthetic preferences of users as well as practical considerations such as convenience, storage, and costs.

  16. Keep your hands crossed: the valence-by-left/right interaction is related to hand, not side, in an incongruent hand-response key assignment.

    PubMed

    de la Vega, Irmgard; Dudschig, Carolin; De Filippis, Mónica; Lachmair, Martin; Kaup, Barbara

    2013-02-01

    The body-specificity hypothesis (Casasanto, 2009) associates positive emotional valence and the space surrounding the dominant hand, and negative valence and the space surrounding the non-dominant hand. This effect has not only been found for manual responses, but also for the left and right side. In the present study, we investigated whether this compatibility effect still shows when hand and side carry incongruent information, and whether it is then related to hand or to side. We conducted two experiments which used an incongruent hand-response key assignment, that is, participants had their hands crossed. Participants were instructed to respond with their right vs. left hand (Experiment 1) or with the right vs. left key (Experiment 2). In both experiments, a compatibility effect related to hand emerged, indicating that the association between hand and valence overrides the one between side and valence when hand and side carry contradicting information. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Rett syndrome

    PubMed Central

    Sitholey, Prabhat; Agarwal, Vivek; Srivastava, Rohit

    2005-01-01

    Rett syndrome is a rare, progressive, neurodevelopmental disorder that has been reported only in the girl child. We describe the case of a 6.9-year-old girl with Rett syndrome. She had normal development till the age of 2 years. However, over the next 4–5 months, she lost her acquired, purposeful hand skills; expressive and receptive language; and reciprocal social interaction; and gradually developed a broad-based gait and typical midline stereotyped hand movements (mouthing, rubbing). PMID:20711295

  18. The Effect of Antibacterial Formula Hand Cleaners on the Elimination of Microbes on Hands

    NASA Astrophysics Data System (ADS)

    Coleman, J. R.

    2002-05-01

    : The purpose of this project is to find out which one of the antibacterial hand cleanser (antibacterial bar soap, antibacterial liquid hand soap, and liquid hand sanitizer) is more effective in eliminating microbes. If antibacterial- formula liquid hand soap is used on soiled hands, then it will be more effective in eliminating microbes. Germs are microorganisms that cause disease and can spread from person-to-person. Bacteria are a kind of microbe, an example of which is Transient Flora that is often found on hands. Hand washing prevents germs from spreading to others. During the procedure, swabs were used to take samples before and after the soiled hands had been washed with one of the antibacterial hand cleansers. Nutrient Easygel was poured into petri dishes to harden for 1 day, and then samples were swabbed on the gel. The Petri dishes were placed in an incubator for 24 hours, and then data was recorded accordingly. The antibacterial liquid hand soap was sufficient in eliminating the majority of bacteria. The hands had 65% of the bacteria on them, and after the liquid hand soap was used only 37% of the bacteria remained.

  19. Effects of electromyography-driven robot-aided hand training with neuromuscular electrical stimulation on hand control performance after chronic stroke.

    PubMed

    Rong, Wei; Tong, Kai Yu; Hu, Xiao Ling; Ho, Sze Kit

    2015-03-01

    An electromyography-driven robot system integrated with neuromuscular electrical stimulation (NMES) was developed to investigate its effectiveness on post-stroke rehabilitation. The performance of this system in assisting finger flexion/extension with different assistance combinations was evaluated in five stroke subjects. Then, a pilot study with 20-sessions training was conducted to evaluate the training's effectiveness. The results showed that combined assistance from the NMES-robot could improve finger movement accuracy, encourage muscle activation of the finger muscles and suppress excessive muscular activities in the elbow joint. When assistances from both NMES and the robot were 50% of their maximum assistances, finger-tracking performance had the best results, with the lowest root mean square error, greater range of motion, higher voluntary muscle activations of the finger joints and lower muscle co-contraction in the finger and elbow joints. Upper limb function improved after the 20-session training, indicated by the increased clinical scores of Fugl-Meyer Assessment, Action Research Arm Test and Wolf Motor Function Test. Muscle co-contraction was reduced in the finger and elbow joints reflected by the Modified Ashworth Scale. The findings demonstrated that an electromyography-driven NMES-robot used for chronic stroke improved hand function and tracking performance. Further research is warranted to validate the method on a larger scale. Implications for Rehabilitation The hand robotics and neuromuscular electrical stimulation (NMES) techniques are still separate systems in current post-stroke hand rehabilitation. This is the first study to investigate the combined effects of the NMES and robot on hand rehabilitation. The finger tracking performance was improved with the combined assistance from the EMG-driven NMES-robot hand system. The assistance from the robot could improve the finger movement accuracy and the assistance from the NMES could reduce the

  20. Meta-analysis suggests that the electromagnetic technique is better than the free-hand method for the distal locking during intramedullary nailing procedures.

    PubMed

    Zhu, Yanbin; Chang, Hengrui; Yu, Yiyang; Chen, Wei; Liu, Song; Zhang, Yingze

    2017-05-01

    To evaluate the comparative effectiveness and accuracy of electromagnetic technique (EM) verses free-hand method (FH) for distal locking in intramedullary nailing procedure. Relevant original studies were searched in Medline, Pubmed, Embase, China National Knowledge Infrastructure, and Cochrane Central Database (all through October 2015). Comparative studies providing sufficient data of interest were included in this meta-analysis. The Stata 11.0 was used to analyze all data. Eight studies involving 611 participants were included, with 305 in EM group and 306 in FH group. EM outperformed FH with reduced distal locking time of 4.1 minutes [standardized mean difference (SMD), 1.61; 95 % confidence interval (95 %CI), 0.81 to 2.41] and the reduced fluoroscopy time of 25.3 seconds (SMD, 2.64; 95 %CI, 2.12 to 3.16). Regarding the accuracy of distal screw placement, no significant difference was observed between two techniques (OR, 2.39; 95 %CI, 0.38 to 15.0). There was a trend of longer operative time in FH versus EM by 10 minutes (79.0 and 69.0 minutes), although the difference was not statistically significant (SMD, 0.341; 95 % CI, -0.02 to 0.703). The existing evidence suggests EM technique is a better alternative for distal locking in intramedullary nailing procedure, and this might aid in the management of diaphyseal fractures in lower extremities.

  1. Ability of Hand Hygiene Interventions Using Alcohol-Based Hand Sanitizers and Soap To Reduce Microbial Load on Farmworker Hands Soiled during Harvest.

    PubMed

    de Aceituno, Anna Fabiszewski; Bartz, Faith E; Hodge, Domonique Watson; Shumaker, David J; Grubb, James E; Arbogast, James W; Dávila-Aviña, Jorgé; Venegas, Fabiola; Heredia, Norma; García, Santos; Leon, Juan S

    2015-11-01

    Effective hand hygiene is essential to prevent the spread of pathogens on produce farms and reduce foodborne illness. The U.S. Food and Drug Administration Food Safety Modernization Act Proposed Rule for Produce Safety recommends the use of soap and running water for hand hygiene of produce handlers. The use of alcohol-based hand sanitizer (ABHS) may be an effective alternative hygiene intervention where access to water is limited. There are no published data on the efficacy of either soap or ABHS-based interventions to reduce microbial contamination in agricultural settings. The goal of this study was to assess the ability of two soap-based (traditional or pumice) and two ABHS-based (label-use or two-step) hygiene interventions to reduce microbes (coliforms, Escherichia coli, and Enterococcus spp.) and soil (absorbance of hand rinsate at 600 nm [A600]) on farmworker hands after harvesting produce, compared with the results for a no-hand-hygiene control. With no hand hygiene, farmworker hands were soiled (median A600, 0.48) and had high concentrations of coliforms (geometric mean, 3.4 log CFU per hand) and Enterococcus spp. (geometric mean, 5.3 log CFU per hand) after 1 to 2 h of harvesting tomatoes. Differences in microbial loads in comparison to the loads in the control group varied by indicator organism and hygiene intervention (0 to 2.3 log CFU per hand). All interventions yielded lower concentrations of Enterococcus spp. and E. coli (P < 0.05), but not of coliforms, than were found in the control group. The two-step ABHS intervention led to significantly lower concentrations of coliforms and Enterococcus spp. than the pumice soap and label-use ABHS interventions (P < 0.05) and was the only intervention to yield significantly fewer samples with E. coli than were found in the control group (P < 0.05). All interventions removed soil from hands (P < 0.05), soap-based interventions more so than ABHS-based interventions (P < 0.05). ABHS-based interventions were

  2. 46 CFR 160.052-8 - Marking.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) provides a minimum buoyant force of (151/2 lb., 11 lb., or 7 lb.). Dry out thoroughly when wet. Approved... vests shall be sufficiently waterproof so that after 72 hours submergence in water it will withstand vigorous rubbing by hand while wet without the printed matter becoming illegible. [CGD 72-163R, 38 FR 8120...

  3. A possible anatomical and biomechanical explanation of the 10% rule used in the clinical assessment of prehensile hand movements and handed dominance.

    PubMed

    Yielder, P; Gutnik, B; Kobrin, V; Hudson, G

    2009-12-01

    A current doctrine in the dynamometric approach to determine lateralization of hand function states that in 10% of cases, the non-dominant hand will be stronger than the dominant hand. In this study, a novel MRI based modelling approach was applied to the first dorsal introsseus muscle (FDI), to determine whether the 10% rule may be applied to the FDI and may be partially explained by the arrangement of the anatomical components of the FDI. Initially the force generated by the thumb segment during an isometric pushing task in the horizontal plane was measured from 25 strongly right-handed young males. Nine of these participants then had structural magnetic resonance imaging (sMRI) of the thumb and index osseous compartment. A modelling technique was developed to extract the muscle data and quantify the muscle line of action onto to the first metacarpal bone segment in order to quantify the muscle force at the point of momentary rotation--equilibrium. Eight of 25 subjects exhibited stronger force from the left hand. Six out of nine subjects from the MRI possessed significantly greater angles of attachment of the index osseous compartment on the left (non-dominant) hand. These six subjects also generated greater maximal isometric forces from the FDI of the left side. There was a significantly greater muscle volume for the right FDI muscle as compared to the left as measured from the reconstructed MRI slice data. The calculated force produced by the muscle is related to the angle of attachment of the muscle to bone in the index osseous compartment. The MRI findings indicate that the 10% rule may be anatomically and biomechanically explained.

  4. A new method for recognizing hand configurations of Brazilian gesture language.

    PubMed

    Costa Filho, C F F; Dos Santos, B L; de Souza, R S; Dos Santos, J R; Costa, M G F

    2016-08-01

    This paper describes a new method for recognizing hand configurations of the Brazilian Gesture Language - LIBRAS - using depth maps obtained with a Kinect® camera. The proposed method comprised three phases: hand segmentation, feature extraction, and classification. The segmentation phase is independent from the background and depends only on pixel depth information. Using geometric operations and numerical normalization, the feature extraction process was done independent from rotation and translation. The features are extracted employing two techniques: (2D)2LDA and (2D)2PCA. The classification is made with a novelty classifier. A robust database was constructed for classifier evaluation, with 12,200 images of LIBRAS and 200 gestures of each hand configuration. The best accuracy obtained was 95.41%, which was greater than previous values obtained in the literature.

  5. Compact Telerobot Hand

    NASA Technical Reports Server (NTRS)

    Rosheim, Mark; Trechsel, Hans

    1993-01-01

    Anthropomorphic telerobotic hand contains actuators, joints, sensors, and complex wiring harnesses. Glove protects interior components of hand from dirt and damage. Imitates motions of human fingers and wrist in lifelike and dexterous way. Incorporates pitch/yaw joints in wrist and head knuckles. Hand modular; so fingers removable, interchangeable units. Feature simplifies servicing and maintenance, which must be done frequently in such complex mechanism.

  6. How to use hand-held computers to evaluate wood drying.

    Treesearch

    Howard N. Rosen; Darrell S. Martin

    1985-01-01

    Techniques have been developed to evaluate end generate wood drying curves with hand-held computers (3-5K memory). Predictions of time to dry to a specific moisture content, drying rates, and other characteristics of wood drying curves can be made. The paper describes the development of programs and illustrates their use.

  7. Left-handed and right-handed U(1) gauge symmetry

    NASA Astrophysics Data System (ADS)

    Nomura, Takaaki; Okada, Hiroshi

    2018-01-01

    We propose a model with the left-handed and right-handed continuous Abelian gauge symmetry; U(1) L × U(1) R . Then three right-handed neutrinos are naturally required to achieve U(1) R anomaly cancellations, while several mirror fermions are also needed to do U(1) L anomaly cancellations. Then we formulate the model, and discuss its testability of the new gauge interactions at collider physics such as the large hadron collider (LHC) and the international linear collider (ILC). In particular, we can investigate chiral structure of the interactions by the analysis of forward-backward asymmetry based on polarized beam at the ILC.

  8. Reduction in finger blood flow induced by hand-transmitted vibration: effect of hand elevation.

    PubMed

    Ye, Ying; Mauro, Marcella; Bovenzi, Massimo; Griffin, Michael J

    2015-10-01

    This study investigated the effect of hand elevation on reductions in finger blood flow (FBF) induced by hand-transmitted vibration. Fourteen males attended six sessions on six separate days, with a control sessions and a vibration session (125-Hz vibration at 44 ms(-2) rms) with the right hand supported at each of three elevations: 20 cm below heart level (HL), at HL, and 20 cm above HL. Finger blood flow on the left and right hand was measured every 30 s during each 25-min session comprised of five periods: (1) no force and no vibration (5 min), (2) 2-N force and no vibration (5 min), (3) 2-N force and vibration (5 min), (4) 2-N force and no vibration (5 min), and (5) no force and no vibration (5 min). Without vibration, FBF decreased with increasing elevation of the hand. During vibration of the right hand, FBF reduced on both hands. With elevation of the right hand, the percentage reduction in FBF due to vibration (relative to FBF on the same finger at the same elevation before exposure to vibration) was similar on the middle and little fingers of both hands. After cessation of vibration, there was delayed return of FBF with all three hand heights. Vibration of one hand reduces FBF on both exposed and unexposed hands, with the reduction dependent on the elevation of the hand. The mechanisms responsible for vibration-induced reductions in FBF seem to reduce blood flow as a percentage of the blood flow without vibration. Tasks requiring the elevation of the hands will be associated with lower FBF, and the FBF will be reduced further if there is exposure to hand-transmitted vibration.

  9. Efficacy of alcohol-based hand sanitizer on hands soiled with dirt and cooking oil.

    PubMed

    Pickering, Amy J; Davis, Jennifer; Boehm, Alexandria B

    2011-09-01

    Handwashing education and promotion are well established as effective strategies to reduce diarrhea and respiratory illness in countries around the world. However, access to reliable water supplies has been identified as an important barrier to regular handwashing in low-income countries. Alcohol-based hand sanitizer (ABHS) is an effective hand hygiene method that does not require water, but its use is not currently recommended when hands are visibly soiled. This study evaluated the efficacy of ABHS on volunteers' hands artificially contaminated with Escherichia coli in the presence of dirt (soil from Tanzania) and cooking oil. ABHS reduced levels of E. coli by a mean of 2.33 log colony forming units (CFU) per clean hand, 2.32 log CFU per dirt-covered hand, and 2.13 log CFU per oil-coated hand. No significant difference in efficacy was detected between hands that were clean versus dirty or oily. ABHS may be an appropriate hand hygiene method for hands that are moderately soiled, and an attractive option for field settings in which access to water and soap is limited.

  10. Hand anthropometry of Indian women.

    PubMed

    Nag, Anjali; Nag, P K; Desai, Hina

    2003-06-01

    Data on the physical dimension of the hand of Indian women are scanty. This information is necessary to ascertain human-machine compatibility in the design of manual systems for the bare and gloved hand, such as design and sizing of hand tools, controls, knobs and other applications in different kinds of precision and power grips. The present study was undertaken to generate hand anthropometric data of 95 women, working in informal industries (beedi, agarbatti and garment making). Fifty one hand measurements of the right hand (lengths, breadths, circumferences, depths, spreads and clearances of hand and fingers) were taken, using anthropometric sliding and spreading calipers, measuring tape and handgrip strength dynamometer. The data were statistically analyzed to determine the normality of data and the percentile values of different hand dimensions, and simple and multiple regression analysis were done to determine better predictors of hand length and grip strength. The hand breadths, circumferences and depths were approximately normally distributed, with some deviation in case of the finger lengths. Hand length was significantly correlated with the fist, wrist and finger circumferences. The fist and wrist circumferences, in combination, were better predictors of hand length. The hand lengths, breadths and depths, including finger joints of the Indian women studied were smaller than those of American, British and West Indian women. The hand circumferences of the Indian women were also smaller than the American women. Grip strengths of Indian women (20.36 +/- 3.24 kg) were less than those of American, British and West Indian women. Grip strength was found to be statistically significant with hand dimensions, such as hand height perpendicular to wrist crease (digit 5), proximal interphalangeal joint breadth (digit 3) and hand spread across wedge 1. The women who are forced to frequently use cutters, strippers and other tools, which are not optimally designed to

  11. Control of Prosthetic Hands via the Peripheral Nervous System

    PubMed Central

    Ciancio, Anna Lisa; Cordella, Francesca; Barone, Roberto; Romeo, Rocco Antonio; Bellingegni, Alberto Dellacasa; Sacchetti, Rinaldo; Davalli, Angelo; Di Pino, Giovanni; Ranieri, Federico; Di Lazzaro, Vincenzo; Guglielmelli, Eugenio; Zollo, Loredana

    2016-01-01

    This paper intends to provide a critical review of the literature on the technological issues on control and sensorization of hand prostheses interfacing with the Peripheral Nervous System (i.e., PNS), and their experimental validation on amputees. The study opens with an in-depth analysis of control solutions and sensorization features of research and commercially available prosthetic hands. Pros and cons of adopted technologies, signal processing techniques and motion control solutions are investigated. Special emphasis is then dedicated to the recent studies on the restoration of tactile perception in amputees through neural interfaces. The paper finally proposes a number of suggestions for designing the prosthetic system able to re-establish a bidirectional communication with the PNS and foster the prosthesis natural control. PMID:27092041

  12. Real-Time Hand Posture Recognition Using a Range Camera

    NASA Astrophysics Data System (ADS)

    Lahamy, Herve

    modeling and finally the recognition process have been described and evaluated extensively. In addition, the performance of this method has been analyzed against several existing hand posture recognition techniques found in literature. The proposed system is able to recognize with an overall recognition rate of 98% and in real-time 18 out the 33 postures of the American sign language alphabet. This recognition is translation, rotation and scale invariant.

  13. Friction. Physical Science in Action[TM]. Schlessinger Science Library. [Videotape].

    ERIC Educational Resources Information Center

    2000

    Most people think friction is what happens when two things are rubbed together. But there's so much more! Friction is a force that resists motion. Yet, without friction, motion would be impossible. Students will learn more about this natural force and the attempts made at controlling it in the world. Includes a hands-on activity and graphic…

  14. Upper limb joint kinetics of three sitting pivot wheelchair transfer techniques in individuals with spinal cord injury.

    PubMed

    Kankipati, Padmaja; Boninger, Michael L; Gagnon, Dany; Cooper, Rory A; Koontz, Alicia M

    2015-07-01

    Repeated measures design. This study compared the upper extremity (UE) joint kinetics between three transfer techniques. Research laboratory. Twenty individuals with spinal cord injury performed three transfer techniques from their wheelchair to a level tub bench. Two of the techniques involved a head-hips method with leading hand position close (HH-I) and far (HH-A) from the body, and the third technique with the trunk upright (TU) and hand far from body. Motion analysis equipment recorded upper body movements and force sensors recorded their hand and feet reaction forces during the transfers. Several significant differences were found between HH-A and HH-I and TU and HH-I transfers indicating that hand placement was a key factor influencing the UE joint kinetics. Peak resultant hand, elbow, and shoulder joint forces were significantly higher for the HH-A and TU techniques at the trailing arm (P < 0.036) and lower at the leading arm (P < 0.021), compared to the HH-I technique. Always trailing with the same arm if using HH-A or TU could predispose that arm to overuse related pain and injuries. Technique training should focus on initial hand placement close to the body followed by the amount of trunk flexion needed to facilitate movement.

  15. Safety of elective hand surgery following axillary lymph node dissection for breast cancer.

    PubMed

    Hershko, Dan D; Stahl, Shalom

    2007-01-01

    The development of lymphedema is the most feared complication shared by breast cancer survivors undergoing hand surgery after prior axillary lymph node dissection (ALND). Traditionally, these patients are advised to avoid any interventional procedures in the ipsilateral upper extremity. However, the appropriateness of some of these precautions was recently challenged by some surgeons claiming that elective hand operations can be safely performed in these patients. The purpose of this study was to evaluate our experience and determine the safety of elective hand operations in breast cancer survivors. The medical records of patients operated for different hand conditions after prior breast surgery and ALND at our institution between 1983 and 2002 were reviewed. The techniques and preventive measures performed, use of antibiotics, and upper extremity complications associated with the operations were analyzed. Overall, we operated on 27 patients after prior ALND performed for breast cancer. Follow-up was available for 25 patients. Four patients had pre-existing lymphedema. The surgical technique used was similar to that performed in patients without prior ALND and antibiotic prophylaxis was not given. Delayed wound healing was observed in one patient and finger joint stiffness in another. Two patients with pre-existing lymphedema developed temporary worsening of their condition. None of the patients developed new lymphedema. The results of the present study support the few previous studies, suggesting that hand surgery can be safely performed in patients with prior ALND. Based on these findings, the appropriateness of the rigorous precautions and prohibitions regarding the care and use of the ipsilateral upper extremity may need to be reconsidered.

  16. Does Navigation Improve Accuracy of Placement of Pedicle Screws in Single-level Lumbar Degenerative Spondylolisthesis?: A Comparison Between Free-hand and Three-dimensional O-Arm Navigation Techniques.

    PubMed

    Boon Tow, Benjamin Phak; Yue, Wai Mun; Srivastava, Abhishek; Lai, Jenn Ming; Guo, Chang Ming; Wearn Peng, Benedict Chan; Chen, John L T; Yew, Andy K S; Seng, Chusheng; Tan, Seang Beng

    2015-10-01

    This was a prospective, nonrandomized study. To assess the accuracy of O-arm navigation-based pedicle screw insertion in lumbar degenerative spondylolisthesis and to compare it with free-hand pedicle screw insertion technique in matched population. O-arm navigation is latest in navigation technology that can provide real-time intraoperative images in 3 dimensions while placing the pedicle screws to improve intraoperative pedicle screw accuracy. Degenerative lumbar spondylolisthesis is a locally unstable pathology and placement of pedicle screws can cause increased rotation and translation of the vertebral body. However, is this motion detected by the tracker placed across the unstable segment, is a matter of debate. Inability to detect these positional changes can lead to pedicle perforation while inserting screws using navigation. No study has evaluated the role of O-arm navigation in this patient population. The study population was divided into 2 groups with 19 patients each, one comprising patients who underwent O-arm navigation-based pedicle screw insertion (group 1) and the other comprising patients who underwent free-hand pedicle screw insertion technique (group 2). A total of 152 pedicle screws were implanted in 38 patients for 1-level instrumented fusion for degenerative lumbar spondylolisthesis. Intraoperative 3-dimensional computed tomography scans using the O-arm were obtained for all patients after insertion of pedicle screws. The images were reviewed intraoperatively and postoperatively for the analysis of pedicle breaches. Assessments in either of the group included (i) accuracy of placement of screws; (ii) the rate and direction of perforation; and (iii) the number of segments the perforated screw was away from the navigation tracker. Mean age of patients in group 1 (O-arm navigation-assisted) was 60 years (SD 11.25; range, 37-73 y), whereas in group 2 (free-hand pedicle screw) was 62 years (SD 18.07; range, 36-90 y). Overall anatomic perforation

  17. Knowledge-based segmentation and feature analysis of hand and wrist radiographs

    NASA Astrophysics Data System (ADS)

    Efford, Nicholas D.

    1993-07-01

    The segmentation of hand and wrist radiographs for applications such as skeletal maturity assessment is best achieved by model-driven approaches incorporating anatomical knowledge. The reasons for this are discussed, and a particular frame-based or 'blackboard' strategy for the simultaneous segmentation of the hand and estimation of bone age via the TW2 method is described. The new approach is structured for optimum robustness and computational efficiency: features of interest are detected and analyzes in order of their size and prominence in the image, the largest and most distinctive being dealt with first, and the evidence generated by feature analysis is used to update a model of hand anatomy and hence guide later stages of the segmentation. Closed bone boundaries are formed by a hybrid technique combining knowledge-based, one-dimensional edge detection with model-assisted heuristic tree searching.

  18. Eye-hand preference in schizophrenia: sex differences and significance for hand function.

    PubMed

    Liu, Yi-Chia; Yang, Yen Kuang; Lee, I Hui; Lin, Keh-Chung; Jeffries, Keith J; Lee, Li-Ching

    2004-06-01

    Hand preference and eye dominance were investigated in 73 (30 women, 43 men) schizophrenic patients and 71 (30 women, 41 men) healthy controls. There were significantly more schizophrenic patients and normal controls who were significantly right-hand dominant. However, schizophrenic patients showed a significant excess of left-eye dominance relative to controls (65.8% vs 29.6%; Odds Ratio= 4.75, p< .001). In addition, female schizophrenic patients showed a higher rate of nonright (either left or inconsistent) eye dominance (80%) than male schizophrenic patients (55.8%) and controls (33.3%). Analysis of hand performance on the Purdue Pegboard Test indicated that schizophrenic patients who showed crossed eye-hand dominance scored higher than did patients without crossed eye-hand dominance.

  19. Hand-held microwave search detector

    NASA Astrophysics Data System (ADS)

    Daniels, David J.; Philippakis, Mike

    2005-05-01

    This paper describes the further development of a patented, novel, low cost, microwave search detector using noise radar technology operating in the 27-40GHz range of frequencies, initially reported in SPIE 2004. Initial experiments have shown that plastic explosives, ceramics and plastic material hidden on the body can be detected with the system. This paper considers the basic physics of the technique and reports on the development of a initial prototype system for hand search of suspects and addresses the work carried out on optimisation of PD and FAR. The radar uses a novel lens system and the design and modelling of this for optimum depth of field of focus will be reported.

  20. Is the hand to speech what speech is to the hand?

    PubMed

    Mildner, V

    2000-01-01

    Interference between the manual and the verbal performance on two types of concurrent verbal-manual tasks was studied on a sample of 48 female right-handers. The more complex verbal task (storytelling) affected both hands significantly, the less complex (essentially phonemic) task affected only the right hand, with insignificant negative influence on the left-hand performance. No significant reciprocal effects of the motor task on verbalization were found.

  1. Assessment of the bacterial contamination of hand air dryer in washrooms.

    PubMed

    Alharbi, Sulaiman Ali; Salmen, Saleh Hussein; Chinnathambi, Arunachalam; Alharbi, Naiyf S; Zayed, M E; Al-Johny, Bassam O; Wainwright, Milton

    2016-03-01

    The present study was carried out, using standard techniques, to identify and count the bacterial contamination of hand air dryers, used in washrooms. Bacteria were isolated from the air flow, outlet nozzle of warm air dryers in fifteen air dryers used in these washrooms. Bacteria were found to be relatively numerous in the air flows. Bacterially contaminated air was found to be emitted whenever a warm air dryer was running, even when not being used for hand drying. Our investigation shows that Staphylococcus haemolyticus, Micrococcus luteus, Pseudomonas alcaligenes, Bacillus cereus and Brevundimonad diminuta/vesicularis were emitted from all of the dryers sampled, with 95% showing evidence of the presence of the potential pathogen S. haemolyticus. It is concluded that hot air dryers can deposit pathogenic bacteria onto the hands and body of users. Bacteria are distributed into the general environment whenever dryers are running and could be inhaled by users and none-users alike. The results provide an evidence base for the development and enhancement of hygienic hand drying practices.

  2. Assessment of the bacterial contamination of hand air dryer in washrooms

    PubMed Central

    Alharbi, Sulaiman Ali; Salmen, Saleh Hussein; Chinnathambi, Arunachalam; Alharbi, Naiyf S.; Zayed, M.E.; Al-Johny, Bassam O.; Wainwright, Milton

    2015-01-01

    The present study was carried out, using standard techniques, to identify and count the bacterial contamination of hand air dryers, used in washrooms. Bacteria were isolated from the air flow, outlet nozzle of warm air dryers in fifteen air dryers used in these washrooms. Bacteria were found to be relatively numerous in the air flows. Bacterially contaminated air was found to be emitted whenever a warm air dryer was running, even when not being used for hand drying. Our investigation shows that Staphylococcus haemolyticus, Micrococcus luteus, Pseudomonas alcaligenes, Bacillus cereus and Brevundimonad diminuta/vesicularis were emitted from all of the dryers sampled, with 95% showing evidence of the presence of the potential pathogen S. haemolyticus. It is concluded that hot air dryers can deposit pathogenic bacteria onto the hands and body of users. Bacteria are distributed into the general environment whenever dryers are running and could be inhaled by users and none-users alike. The results provide an evidence base for the development and enhancement of hygienic hand drying practices. PMID:26981009

  3. Detection of pathogenic micro-organisms on children's hands and toys during play.

    PubMed

    Martínez-Bastidas, T; Castro-del Campo, N; Mena, K D; Castro-del Campo, N; León-Félix, J; Gerba, C P; Chaidez, C

    2014-06-01

    This study aimed to determine if the children's leisure activities impact the presence of pathogens on their hands and toys. To assess the microbiological hazard in playground areas, a pilot study that included 12 children was conducted. We then conducted an intervention study; children's hands and toys were washed before playing. Faecal coliforms, pathogenic bacteria and Giardia lamblia were quantified by membrane filtration, selective media and flotation techniques, respectively; rotavirus, hepatitis A and rhinovirus by RT-PCR. Pilot study results revealed faecal contamination on children's hands and toys after playing on sidewalks and in public parks. Pathogenic bacteria, hepatitis A and G. lamblia on children's hands were also found. In the intervention study, Staphylococcus aureus and Klebsiella pneumoniae were found on children's hands at concentrations up to 2·5 × 10(4) and 1 × 10(4) CFU hands(-1), respectively. E. coli and Kl. pneumoniae were detected on toys (2·4 × 10(3) and 2·7 × 10(4) CFU toy(-1), respectively). Salmonella spp, Serratia spp and G. lamblia cysts were also present on toys. Children's play activities influence microbial presence on hands and toys; the transfer seems to occur in both ways. Control strategy needs to be implemented to protect children from infectious diseases. © 2014 The Society for Applied Microbiology.

  4. Hands-on Science: Does It Matter What Students' Hands Are On?

    ERIC Educational Resources Information Center

    Triona, Lara M.; Klahr, David

    2007-01-01

    Hands-on science typically uses physical materials to give students first-hand experience in scientific methodologies, but the recent availability of virtual laboratories raises an important question about whether what students' hands are on matters to their learning. The overall findings of two articles that employed simple comparisons of…

  5. Hand aperture patterns in prehension.

    PubMed

    Bongers, Raoul M; Zaal, Frank T J M; Jeannerod, Marc

    2012-06-01

    Although variations in the standard prehensile pattern can be found in the literature, these alternative patterns have never been studied systematically. This was the goal of the current paper. Ten participants picked up objects with a pincer grip. Objects (3, 5, or 7cm in diameter) were placed at 30, 60, 90, or 120cm from the hands' starting location. Usually the hand was opened gradually to a maximum immediately followed by hand closing, called the standard hand opening pattern. In the alternative opening patterns the hand opening was bumpy, or the hand aperture stayed at a plateau before closing started. Two participants in particular delayed the start of grasping with respect to start of reaching, with the delay time increasing with object distance. For larger object distances and smaller object sizes, the bumpy and plateau hand opening patterns were used more often. We tentatively concluded that the alternative hand opening patterns extended the hand opening phase, to arrive at the appropriate hand aperture at the appropriate time to close the hand for grasping the object. Variations in hand opening patterns deserve attention because this might lead to new insights into the coordination of reaching and grasping. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Comparison of non-invasive tear film stability measurement techniques.

    PubMed

    Wang, Michael Tm; Murphy, Paul J; Blades, Kenneth J; Craig, Jennifer P

    2018-01-01

    Measurement of tear film stability is commonly used to give an indication of tear film quality but a number of non-invasive techniques exists within the clinical setting. This study sought to compare three non-invasive tear film stability measurement techniques: instrument-mounted wide-field white light clinical interferometry, instrument-mounted keratoscopy and hand-held keratoscopy. Twenty-two subjects were recruited in a prospective, randomised, masked, cross-over study. Tear film break-up or thinning time was measured non-invasively by independent experienced examiners, with each of the three devices, in a randomised order, within an hour. Significant correlation was observed between instrument-mounted interferometric and keratoscopic measurements (p < 0.001) but not between the hand-held device and the instrument-mounted techniques (all p > 0.05). Tear film stability values obtained from the hand-held device were significantly shorter and demonstrated narrower spread than the other two instruments (all p < 0.05), while no significant differences were observed between the two instrument-mounted devices (all p > 0.05). Good clinical agreement exists between the instrument-mounted interferometric and keratoscopic measurements but not between the hand-held device and either of the instrument-mounted techniques. The results highlight the importance of specifying the instrument employed to record non-invasive tear film stability. © 2017 Optometry Australia.

  7. Prism adaptation in alternately exposed hands.

    PubMed

    Redding, Gordon M; Wallace, Benjamin

    2013-08-01

    We assessed intermanual transfer of the proprioceptive realignment aftereffects of prism adaptation in right-handers by examining alternate target pointing with the two hands for 40 successive trials, 20 with each hand. Adaptation for the right hand was not different as a function of exposure sequence order or postexposure test order, in contrast with adaptation for the left hand. Adaptation was greater for the left hand when the right hand started the alternate pointing than when the sequence of target-pointing movements started with the left hand. Also, the largest left-hand adaptation appeared when that hand was tested first after exposure. Terminal error during exposure varied in cycles for the two hands, converging on zero when the right hand led, but no difference appeared between the two hands when the left hand led. These results suggest that transfer of proprioceptive realignment occurs from the right to the left hand during both exposure and postexposure testing. Such transfer reflects the process of maintaining spatial alignment between the two hands. Normally, the left hand appears to be calibrated with the right-hand spatial map, and when the two hands are misaligned, the left-hand spatial map is realigned with the right-hand spatial map.

  8. Grapefruit (Citrus paradisi Macfad) phytochemicals composition is modulated by household processing techniques.

    PubMed

    Uckoo, Ram M; Jayaprakasha, Guddadarangavvanahally K; Balasubramaniam, V M; Patil, Bhimanagouda S

    2012-09-01

    Grapefruits (Citrus paradisi Macfad) contain several phytochemicals known to have health maintaining properties. Due to the consumer's interest in obtaining high levels of these phytochemicals, it is important to understand the changes in their levels by common household processing techniques. Therefore, mature Texas "Rio Red" grapefruits were processed by some of the common household processing practices such as blending, juicing, and hand squeezing techniques and analyzed for their phytochemical content by high performance liquid chromatography (HPLC). Results suggest that grapefruit juice processed by blending had significantly (P < 0.05) higher levels of flavonoids (narirutin, naringin, hesperidin, neohesperidin, didymin, and poncirin) and limonin compared to juicing and hand squeezing. No significant variation in their content was noticed in the juice processed by juicing and hand squeezing. Ascorbic acid and citric acid were significantly (P < 0.05) higher in juice processed by juicing and blending, respectively. Furthermore, hand squeezed fruit juice had significantly higher contents of dihydroxybergamottin (DHB) than juice processed by juicing and blending. Bergamottin and 5-methoxy-7 gernoxycoumarin (5-M-7-GC) were significantly higher in blended juice compared to juicing and hand squeezing. Therefore, consuming grapefruit juice processed by blending may provide higher levels of health beneficial phytochemicals such as naringin, narirutin, and poncirin. In contrast, juice processed by hand squeezing and juicing provides lower levels of limonin, bergamottin, and 5-M-7-GC. These results suggest that, processing techniques significantly influence the levels of phytochemicals and blending is a better technique for obtaining higher levels of health beneficial phytochemicals from grapefruits. Practical Application:  Blending, squeezing, and juicing are common household processing techniques used for obtaining fresh grapefruit juice. Understanding the levels of

  9. [Results of treatment for high-pressure injection hand injuries].

    PubMed

    Zyluk, A; Walaszek, I

    2000-01-01

    High-pressure injection injuries of the hand have a reputation for being dangerous for individual fingers and even for whole hand. Usually appearing innocuous at presentation because of small puncture entry wound, these injuries result in severe damage of most internal structures in finger and hand due to extensive penetration of injected substance. This paper reviews the outcome of the treatment of such injuries in 10 patients: 9 sustained injection of toxic paint, and one lead shot. All the patients were operated on: eight a few hours after injury and two with 3 days delay. The surgical technique included wide exposure from site of injection up to the farthest place in which foreign substance was seen. Thorough debridment of injected material and contaminated tissue was performed with careful preservation of neurovascular structures and tendons. Wounds were not closed, but managed by open technique. In all patients wounds healed well: in 3 by secondary intention, in 6 by delayed closure and 2 were covered by skin grafts. No amputation was performed. Final results were assessed form 1.5 to 3.5 years after initial injury (mean at 2.5 years). Two patients complained of moderate pain related to the weather, five of cold intolerance and two of impaired sensation on fingertips. Active range of motion of affected fingers was in whole group from 90% to 104% (mean 97%) of the range of motion of unaffected fingers from the other side. Range of motion of the wrist (2 patients) was 76% and 117% of range of motion of the other side. Pinch grip strength was from 81% to 116% (mean 99%), and global grip strength from 77% to 119% (mean 97%) of the other side. All patients went back to their previous jobs and periods of sick leave were from 2 weeks to 6 months (mean 3 mo). Excellent results achieved in this study--full functional recovery in 9 of 10 patients confirm the effectiveness of aggressive treatment by open wound technique of such injuries.

  10. The da vinci robot system eliminates multispecialty surgical trainees' hand dominance in open and robotic surgical settings.

    PubMed

    Badalato, Gina M; Shapiro, Edan; Rothberg, Michael B; Bergman, Ari; RoyChoudhury, Arindam; Korets, Ruslan; Patel, Trushar; Badani, Ketan K

    2014-01-01

    Handedness, or the inherent dominance of one hand's dexterity over the other's, is a factor in open surgery but has an unknown importance in robot-assisted surgery. We sought to examine whether the robotic surgery platform could eliminate the effect of inherent hand preference. Residents from the Urology and Obstetrics/Gynecology departments were enrolled. Ambidextrous and left-handed subjects were excluded. After completing a questionnaire, subjects performed three tasks modified from the Fundamentals of Laparoscopic Surgery curriculum. Tasks were performed by hand and then with the da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, California). Participants were randomized to begin with using either the left or the right hand, and then switch. Left:right ratios were calculated from scores based on time to task completion. Linear regression analysis was used to determine the significance of the impact of surgical technique on hand dominance. Ten subjects were enrolled. The mean difference in raw score performance between the right and left hands was 12.5 seconds for open tasks and 8 seconds for robotic tasks (P<.05). Overall left-right ratios were found to be 1.45 versus 1.12 for the open and robot tasks, respectively (P<.05). Handedness significantly differed between robotic and open approaches for raw time scores (P<.0001) and left-right ratio (P=.03) when controlling for the prior tasks completed, starting hand, prior robotic experience, and comfort level. These findings remain to be validated in larger cohorts. The robotic technique reduces hand dominance in surgical trainees across all task domains. This finding contributes to the known advantages of robotic surgery.

  11. Concept and Design of a 3D Printed Support to Assist Hand Scanning for the Realization of Customized Orthosis.

    PubMed

    Baronio, Gabriele; Volonghi, Paola; Signoroni, Alberto

    2017-01-01

    In the rehabilitation field, the use of additive manufacturing techniques to realize customized orthoses is increasingly widespread. Obtaining a 3D model for the 3D printing phase can be done following different methodologies. We consider the creation of personalized upper limb orthoses, also including fingers, starting from the acquisition of the hand geometry through accurate 3D scanning. However, hand scanning procedure presents differences between healthy subjects and patients affected by pathologies that compromise upper limb functionality. In this work, we present the concept and design of a 3D printed support to assist hand scanning of such patients. The device, realized with FDM additive manufacturing techniques in ABS material, allows palmar acquisitions, and its design and test are motivated by the following needs: (1) immobilizing the hand of patients during the palmar scanning to reduce involuntary movements affecting the scanning quality and (2) keeping hands open and in a correct position, especially to contrast the high degree of hypertonicity of spastic subjects. The resulting device can be used indifferently for the right and the left hand; it is provided in four-dimensional sizes and may be also suitable as a palmar support for the acquisition of the dorsal side of the hand.

  12. Concept and Design of a 3D Printed Support to Assist Hand Scanning for the Realization of Customized Orthosis

    PubMed Central

    Volonghi, Paola

    2017-01-01

    In the rehabilitation field, the use of additive manufacturing techniques to realize customized orthoses is increasingly widespread. Obtaining a 3D model for the 3D printing phase can be done following different methodologies. We consider the creation of personalized upper limb orthoses, also including fingers, starting from the acquisition of the hand geometry through accurate 3D scanning. However, hand scanning procedure presents differences between healthy subjects and patients affected by pathologies that compromise upper limb functionality. In this work, we present the concept and design of a 3D printed support to assist hand scanning of such patients. The device, realized with FDM additive manufacturing techniques in ABS material, allows palmar acquisitions, and its design and test are motivated by the following needs: (1) immobilizing the hand of patients during the palmar scanning to reduce involuntary movements affecting the scanning quality and (2) keeping hands open and in a correct position, especially to contrast the high degree of hypertonicity of spastic subjects. The resulting device can be used indifferently for the right and the left hand; it is provided in four-dimensional sizes and may be also suitable as a palmar support for the acquisition of the dorsal side of the hand. PMID:29234219

  13. New method for determination of efficacy of health care personnel hand wash products.

    PubMed Central

    Mahl, M C

    1989-01-01

    A method of studying the effects of health care personnel hand wash products is described. The fingernail regions of the hands of volunteers are inoculated with a mixture of Escherichia coli and Serratia marcescens, and the areas are dried for a standard time. After routine hand washing, each fingernail region is individually scrubbed with an electric toothbrush which moves longitudinally to the handle into collection fluid contained in a petri dish. The test bacteria in the fluid are then enumerated. (Bacillus subtilis spores may be included as tracers to show degree of physical removal of the procedure.) This method has several advantages over the frequently used glove juice technique. Experimental designs with large numbers of volunteers, multiple sampling sites, and many hand wash products may be performed. Ten sampling sites (fingers) are available, versus the two gloved hands for testing products. (Efficiency is almost 100% in the recovery of spore tracers placed on the fingernails.) Many commercial health care personnel hand wash products containing antimicrobial agents substantive to the skin do not rapidly reduce numbers of inoculated bacteria in the fingernail regions to any greater extent than nonantimicrobial hand washes. Products containing isopropanol or ethanol are very effective in decreasing bacteria in areas around and under the fingernails. PMID:2685028

  14. Hand fracture - aftercare

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000552.htm Hand fracture - aftercare To use the sharing features on ... need to be repaired with surgery. Types of Hand Fractures Your fracture may be in one of ...

  15. Physical examination of the hand.

    PubMed

    Kenney, Raymond J; Hammert, Warren C

    2014-11-01

    Examination of the hand is an essential piece of a hand surgeon's skill set. This current concepts review presents a systematic process of performing a comprehensive physical examination of the hand including vascular, sensory, and motor assessments. Evaluations focused on specific hand diseases and injuries are also discussed. This information can be useful for any health care provider treating patients with hand conditions. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  16. Determination of hand soil loading, soil transfer, and particle size variations after hand-pressing and hand-mouthing activities

    EPA Science Inventory

    Hand-pressing trials and hand-to-mouth soil transfer experiments were conducted to better understand soil loadings, soil transfer ratios for three mouthing activities, and variations in particle size distributions under various conditions. Results indicated that sand caused highe...

  17. Coordination of hand shape.

    PubMed

    Pesyna, Colin; Pundi, Krishna; Flanders, Martha

    2011-03-09

    The neural control of hand movement involves coordination of the sensory, motor, and memory systems. Recent studies have documented the motor coordinates for hand shape, but less is known about the corresponding patterns of somatosensory activity. To initiate this line of investigation, the present study characterized the sense of hand shape by evaluating the influence of differences in the amount of grasping or twisting force, and differences in forearm orientation. Human subjects were asked to use the left hand to report the perceived shape of the right hand. In the first experiment, six commonly grasped items were arranged on the table in front of the subject: bottle, doorknob, egg, notebook, carton, and pan. With eyes closed, subjects used the right hand to lightly touch, forcefully support, or imagine holding each object, while 15 joint angles were measured in each hand with a pair of wired gloves. The forces introduced by supporting or twisting did not influence the perceptual report of hand shape, but for most objects, the report was distorted in a consistent manner by differences in forearm orientation. Subjects appeared to adjust the intrinsic joint angles of the left hand, as well as the left wrist posture, so as to maintain the imagined object in its proper spatial orientation. In a second experiment, this result was largely replicated with unfamiliar objects. Thus, somatosensory and motor information appear to be coordinated in an object-based, spatial-coordinate system, sensitive to orientation relative to gravitational forces, but invariant to grasp forcefulness.

  18. Effects of a new mild shampoo for preventing hair loss in Asian by a simple hand-held phototrichogram technique.

    PubMed

    Baek, J H; Lee, S Y; Yoo, M; Park, W-S; Lee, S J; Boo, Y C; Koh, J-S

    2011-12-01

    This study was conducted to evaluate the effects of a commercially available shampoo in Korean subjects with alopecia using a simple hand-held phototrichogram technique. Forty-four subjects with alopecia were enrolled and forty subjects continued for 16 weeks. In the test group, total hair counts increased significantly at weeks 8 and 16, and the number of shedding hair significantly decreased at week 16. Terminal hair counts significantly increased at week 8. In the control group, hair thickness and the number of vellus hairs significantly decreased at week 16. The number of total hairs significantly increased in the test group than in the control group at weeks 8 and 16. The number of shedding hairs significantly decreased in the test group than in the control group at week 16. Visual assessment using clinical digital images showed that the number of total hairs appeared to increase although there was no statistical significance. In this study, it was found that the test shampoo could prevent hair loss. © 2011 DERMAPRO Co Ltd. ICS © 2011 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  19. Reduction of illness absenteeism in elementary schools using an alcohol-free instant hand sanitizer.

    PubMed

    White, C G; Shinder, F S; Shinder, A L; Dyer, D L

    2001-10-01

    Hand washing is the most effective way to prevent the spread of communicable disease. The purpose of this double-blind, placebo-controlled study was to assess whether an alcohol-free, instant hand sanitizer containing surfactants, allantoin, and benzalkonium chloride could reduce illness absenteeism in a population of 769 elementary school children and serve as an effective alternative when regular soap and water hand washing was not readily available. Prior to the study, students were educated about proper hand washing technique, the importance of hand washing to prevent transmission of germs, and the relationship between germs and illnesses. Children in kindergarten through the 6th grade (ages 5-12) were assigned to the active or placebo hand-sanitizer product and instructed to use the product at scheduled times during the day and as needed after coughing or sneezing. Data on illness absenteeism were tracked. After 5 weeks, students using the active product were 33% less likely to have been absent because of illness when compared with the placebo group.

  20. Inexpensive and Time-Efficient Hand Hygiene Interventions Increase Elementary School Children's Hand Hygiene Rates

    ERIC Educational Resources Information Center

    Snow, Michelle; White, George L.; Kim, Han S.

    2008-01-01

    Routine hand hygiene has been cited by the World Health Organization and the Centers for Disease Control and Prevention as a cost-effective and important hygiene measure in preventing the spread of infectious diseases. Several studies have explored children's hand hygiene habits, effects of scheduled hand hygiene, hand hygiene environmental…

  1. Hands-On Teaching through a Student Field Project in Applied Geophysics.

    ERIC Educational Resources Information Center

    Klasner, John Samuel; Crockett, Jeffrey Jon; Horton, Kimberly Beth; Poe, Michele Daun; Wollert, Matthew Todd

    1992-01-01

    Describes the Proffit Mountain project, part of a senior-level class in applied geophysics that provides students with hands-on experience in applying principles and techniques learned in class. Students conduct magnetic, gravity, and radiometric studies over a diabase body which intrudes rhyolite at Proffitt Mountain in southeast Missouri.…

  2. Upper limb joint kinetics of three sitting pivot wheelchair transfer techniques in individuals with spinal cord injury

    PubMed Central

    Kankipati, Padmaja; Boninger, Michael L.; Gagnon, Dany; Cooper, Rory A.; Koontz, Alicia M.

    2015-01-01

    Study design Repeated measures design. Objective This study compared the upper extremity (UE) joint kinetics between three transfer techniques. Setting Research laboratory. Methods Twenty individuals with spinal cord injury performed three transfer techniques from their wheelchair to a level tub bench. Two of the techniques involved a head–hips method with leading hand position close (HH-I) and far (HH-A) from the body, and the third technique with the trunk upright (TU) and hand far from body. Motion analysis equipment recorded upper body movements and force sensors recorded their hand and feet reaction forces during the transfers. Results Several significant differences were found between HH-A and HH-I and TU and HH-I transfers indicating that hand placement was a key factor influencing the UE joint kinetics. Peak resultant hand, elbow, and shoulder joint forces were significantly higher for the HH-A and TU techniques at the trailing arm (P < 0.036) and lower at the leading arm (P < 0.021), compared to the HH-I technique. Conclusion Always trailing with the same arm if using HH-A or TU could predispose that arm to overuse related pain and injuries. Technique training should focus on initial hand placement close to the body followed by the amount of trunk flexion needed to facilitate movement. PMID:25130053

  3. Two-Thumbed Robot Hand

    NASA Technical Reports Server (NTRS)

    Lee, Sukhan

    1989-01-01

    Robot hand includes thumblike members on left and right sides and fingerlike member at middle. Configuration of digits enables hand to adapt to variously shaped objects, grasp them robustly and reliably, and manipulate them. Reduces complexity of control mechanisms and provides kinesthetic perception of shapes of grasped objects. Mechanical hand with two thumbs and middle finger made from commercially available components. With specially designed dc motors and assemblies of gears, size of hand reduced considerably. Suited to handling objects in industrial tasks.

  4. Hesitation and error: Does product placement in an emergency department influence hand hygiene performance?

    PubMed

    Stackelroth, Jenny; Sinnott, Michael; Shaban, Ramon Z

    2015-09-01

    Existing research has consistently demonstrated poor compliance by health care workers with hand hygiene standards. This study examined the extent to which incorrect hand hygiene occurred as a result of the inability to easily distinguish between different hand hygiene solutions placed at washbasins. A direct observational method was used using ceiling-mounted, motion-activated video camera surveillance in a tertiary referral emergency department in Australia. Data from a 24-hour period on day 10 of the recordings were collected into the Hand Hygiene-Technique Observation Tool based on Feldman's criteria as modified by Larson and Lusk. A total of 459 episodes of hand hygiene were recorded by 6 video cameras in the 24-hour period. The observed overall rate of error in this study was 6.2% (27 episodes). In addition an overall rate of hesitation was 5.8% (26 episodes). There was no statistically significant difference in error rates with the 2 hand washbasin configurations. The amelioration of causes of error and hesitation by standardization of the appearance and relative positioning of hand hygiene solutions at washbasins may translate in to improved hand hygiene behaviors. Placement of moisturizer at the washbasin may not be essential. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  5. Programming of left hand exploits task set but that of right hand depends on recent history.

    PubMed

    Tang, Rixin; Zhu, Hong

    2017-07-01

    There are many differences between the left hand and the right hand. But it is not clear if there is a difference in programming between left hand and right hand when the hands perform the same movement. In current study, we carried out two experiments to investigate whether the programming of two hands was equivalent or they exploited different strategies. In the first experiment, participants were required to use one hand to grasp an object with visual feedback or to point to the center of one object without visual feedback on alternate trials, or to grasp an object without visual feedback and to point the center of one object with visual feedback on alternating trials. They then performed the tasks with the other hand. The result was that previous pointing task affected current grasping when it was performed by the left hand, but not the right hand. In experiment 2, we studied if the programming of the left (or right) hand would be affected by the pointing task performed on the previous trial not only by the same hand, but also by the right (or left) hand. Participants pointed and grasped the objects alternately with two hands. The result was similar with Experiment 1, i.e., left-hand grasping was affected by right-hand pointing, whereas right-hand grasping was immune from the interference from left hand. Taken together, the results suggest that when open- and closed-loop trials are interleaved, motor programming of grasping with the right hand was affected by the nature of the online feedback on the previous trial only if it was a grasping trial, suggesting that the trial-to-trial transfer depends on sensorimotor memory and not on task set. In contrast, motor programming of grasping with the left hand can use information about the nature of the online feedback on the previous trial to specify the parameters of the movement, even when the type of movement that occurred was quite different (i.e., pointing) and was performed with the right hand. This suggests that

  6. Vascular hand-arm vibration syndrome--magnetic resonance angiography.

    PubMed

    Poole, C J M; Cleveland, T J

    2016-01-01

    The diagnosis of vascular hand-arm vibration syndrome (HAVS) requires consistent symptoms, photographic evidence of digital blanching and sufficient exposure to hand-transmitted vibration (HTV; A(8) > 2.5 m/s2). There is no reliable quantitative investigation for distinguishing HAVS from other causes of Raynaud's phenomenon and from normal individuals. Hypothenar and thenar hammer syndromes produce similar symptoms to HAVS but are difficult to diagnose clinically and may be confused with HAVS. Magnetic resonance angiography (MRA) is a safe and minimally invasive method of visualizing blood vessels. Three cases of vascular HAVS are described in which MRA revealed occlusions of the ulnar, radial and superficial palmar arteries. It is proposed that HTV was the cause of these occlusions, rather than blows to the hand unrelated to vibration, the assumed mechanism for the hammer syndromes. All three cases were advised not to expose their hands to HTV despite one of them being at Stockholm vascular stage 2 (early). MRA should be the investigation of choice for stage 2 vascular HAVS or vascular HAVS with unusual features or for a suspected hammer syndrome. The technique is however technically challenging and best done in specialist centres in collaboration with an occupational physician familiar with the examination of HAVS cases. Staging for HAVS should be developed to include anatomical arterial abnormalities as well as symptoms and signs of blanching. Workers with only one artery supplying a hand, or with only one palmar arch, may be at increased risk of progression and therefore should not be exposed to HTV irrespective of their Stockholm stage. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Reduction in bacterial counts in infected root canals after rotary or hand nickel-titanium instrumentation--a clinical study.

    PubMed

    Rôças, I N; Lima, K C; Siqueira, J F

    2013-07-01

    To compare the antibacterial efficacy of two instrumentation techniques, one using hand nickel-titanium (NiTi) instruments and the other using rotary NiTi instruments, in root canals of teeth with apical periodontitis. Root canals from single-rooted teeth were instrumented using either hand NiTi instruments in the alternated rotation motion technique or rotary BioRaCe instruments. The irrigant used in both groups was 2.5% NaOCl. DNA extracts from samples taken before and after instrumentation were subjected to quantitative analysis by real-time polymerase chain reaction (qPCR). Qualitative analysis was also performed using presence/absence data from culture and qPCR assays. Bacteria were detected in all S1 samples by both methods. In culture analysis, 45% and 35% of the canals were still positive for bacterial presence after hand and rotary NiTi instrumentation, respectively (P > 0.05). Rotary NiTi instrumentation resulted in significantly fewer qPCR-positive cases (60%) than hand NiTi instrumentation (95%) (P = 0.01). Intergroup comparison of quantitative data showed no significant difference between the two techniques. There was no significant difference in bacterial reduction in infected canals after instrumentation using hand or rotary NiTi instruments. In terms of incidence of positive results for bacteria, culture also showed no significant differences between the groups, but the rotary NiTi instrumentation resulted in more negative results in the more sensitive qPCR analysis. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  8. The use of joint mobilization to improve clinical outcomes in hand therapy: a systematic review of the literature.

    PubMed

    Heiser, Rick; O'Brien, Virginia H; Schwartz, Deborah A

    2013-01-01

    Systematic review. Joint mobilizations are used as an intervention for improving range of motion, decreasing pain and ultimately improving function in patients with a wide variety of upper extremity diagnoses. However, there are only a limited number of studies describing this treatment for conditions affecting the elbow, wrist, and hand. Furthermore, it is unclear as to the most effective joint mobilization technique utilized and the most beneficial functional outcomes gained. Examine the current evidence describing joint mobilizations for treatment of conditions of the elbow, wrist and hand, and offer informative practical clinical guidance. Twenty-two studies dated between 1980 and 2011 were included in the systematic review for analysis. The current evidence provides moderate support for the inclusion of joint mobilizations in the treatment of lateral epicondylalgia (LE). In particular, mobilization with movement as described by Mulligan is supported with evidence from nine randomized clinical trials as an effective technique for the treatment of pain. Other described techniques include those known as Kaltenborn, Cyriax physical therapy, and Maitland, but the evidence for these techniques is limited. There is also limited evidence for the joint mobilizations in the treatment of wrist and hand conditions. The current literature offers limited support for joint mobilizations of the wrist and hand, and moderate support for joint mobilizations of the elbow for LE. There is moderate support for mobilization with movement. . Copyright © 2013 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  9. iHand: an interactive bare-hand-based augmented reality interface on commercial mobile phones

    NASA Astrophysics Data System (ADS)

    Choi, Junyeong; Park, Jungsik; Park, Hanhoon; Park, Jong-Il

    2013-02-01

    The performance of mobile phones has rapidly improved, and they are emerging as a powerful platform. In many vision-based applications, human hands play a key role in natural interaction. However, relatively little attention has been paid to the interaction between human hands and the mobile phone. Thus, we propose a vision- and hand gesture-based interface in which the user holds a mobile phone in one hand but sees the other hand's palm through a built-in camera. The virtual contents are faithfully rendered on the user's palm through palm pose estimation, and reaction with hand and finger movements is achieved that is recognized by hand shape recognition. Since the proposed interface is based on hand gestures familiar to humans and does not require any additional sensors or markers, the user can freely interact with virtual contents anytime and anywhere without any training. We demonstrate that the proposed interface works at over 15 fps on a commercial mobile phone with a 1.2-GHz dual core processor and 1 GB RAM.

  10. Unimanual SNARC Effect: Hand Matters.

    PubMed

    Riello, Marianna; Rusconi, Elena

    2011-01-01

    A structural representation of the hand embedding information about the identity and relative position of fingers is necessary to counting routines. It may also support associations between numbers and allocentric spatial codes that predictably interact with other known numerical spatial representations, such as the mental number line (MNL). In this study, 48 Western participants whose typical counting routine proceeded from thumb-to-little on both hands performed magnitude and parity binary judgments. Response keys were pressed either with the right index and middle fingers or with the left index and middle fingers in separate blocks. 24 participants responded with either hands in prone posture (i.e., palm down) and 24 participants responded with either hands in supine (i.e., palm up) posture. When hands were in prone posture, the counting direction of the left hand conflicted with the direction of the left-right MNL, whereas the counting direction of the right hand was consistent with it. When hands were in supine posture, the opposite was true. If systematic associations existed between relative number magnitude and an allocentric spatial representation of the finger series within each hand, as predicted on the basis of counting habits, interactions would be expected between hand posture and a unimanual version of the spatial-numerical association of response codes (SNARC) effect. Data revealed that with hands in prone posture a unimanual SNARC effect was present for the right hand, and with hands in supine posture a unimanual SNARC effect was present for the left hand. We propose that a posture-invariant body structural representation of the finger series provides a relevant frame of reference, a within-hand directional vector, that is associated to simple number processing. Such frame of reference can significantly interact with stimulus-response correspondence effects, like the SNARC, that have been typically attributed to the mapping of numbers on a left

  11. Hand osteoarthritis: an epidemiological perspective.

    PubMed

    Kalichman, Leonid; Hernández-Molina, Gabriela

    2010-06-01

    Hand osteoarthritis (OA) is a highly prevalent condition with a wide spectrum of clinical presentations. We review herein the prevalence, impact on hand function, and various risk factors related to hand OA. PubMed and MEDLINE databases (1950-2009) were searched for the keywords: "hand," "hand osteoarthritis," "distal interphalangeal," "proximal interphalangeal," "metacarpophalangeal," and "carpometacarpal." Published material emphasizing cohort, cross-sectional, and case-control studies regarding epidemiology, clinical features, functional impairment, and associated risk factors of hand OA were included. Hand OA is a heterogeneous, age- and gender-dependent disorder, occurring more frequently in women over 50 years of age. In the elderly population, the prevalence of radiographic hand OA can reach 80%. OA has a strong genetic predisposition, apparently gender- and phenotype-specific. A history of heavy manual labor or a repetitive use of the hand also has been linked to OA. Other variables such as weight, smoking, joint hyperlaxity, age of menarche, bone and cartilage mineralization factors, grip strength, and handedness may play a role. Symptomatic hand OA may cause functional impairment due to loss of strength, thus limiting the individual's ability to perform daily tasks. Several risk factors for hand OA have been identified; however, their interrelationship is not clearly understood. The development of preventive strategies and future research goals is needed. Copyright 2010 Elsevier Inc. All rights reserved.

  12. Hand-transmitted vibration and biodynamic response of the human hand-arm: a critical review.

    PubMed

    Dong, R G; Rakheja, S; Schopper, A W; Han, B; Smutz, W P

    2001-01-01

    Hand-arm vibration syndrome (HAVS) has been associated with prolonged exposure to vibration transmitted to the human hand-arm system from hand-held power tools, vibrating machines, or hand-held vibrating workpieces. The biodynamic response of the human hand and arm to hand transmitted vibration (HTV) forms an essential basis for effective evaluations of exposures, vibration-attenuation mechanisms, and potential injury mechanisms. The biodynamic response to HTV and its relationship to HAVS are critically reviewed and discussed to highlight the advances and the need for further research. In view of its strong dependence on the nature of HTV and the lack of general agreement on the characteristics of HTV, the reported studies are first reviewed to enhance an understanding of HTV and related issues. The characteristics of HTV and relevant unresolved issues are discussed on the basis of measured data, proposed standards, and measurement methods, while the need for further developments in measurement systems is emphasized. The studies on biodynamic response and their findings are grouped into four categories based on the methodology used and the objective. These include studies on (1) through-the-hand-arm response, expressed in terms of vibration transmissibility; (2) to-the-hand response, expressed in terms of the force-motion relationship of the hand-arm system; (3) to-the-hand biodynamic response function, expressed in terms of vibration energy absorption; and (4) computer modeling of the biodynamic response characteristics.

  13. Patterns of behavior across reproductive states of free-ranging female black-handed spider monkeys (Ateles geoffroyi).

    PubMed

    Campbell, Christina J

    2004-06-01

    Reports on the behavior of spider monkeys (genus Ateles) describe a suite of 5-6 behaviors that are indicative of an estrous female. This study presents hormonal data as an independent measure of reproductive state to determine if these behaviors are associated with any particular reproductive state or stage of the ovarian cycle. Fecal samples collected from 6 free-ranging female black-handed spider monkeys (Ateles geoffroyi) over the course of 11 months were assayed for estrogen (E1C) and progesterone (PdG) metabolites, using an enzyme immunoassay. Behavioral data collected from the same females were analyzed for patterns associated with different reproductive states. A more detailed analysis of behavioral data associated with reproductively cycling periods determined whether each behavior clustered with copulations or a particular phase in the ovarian cycle. Observations of place-sniffing were more frequent for 4 of 5 females when reproductively cycling. Of all copulations observed, 80% occurred when the female participant was reproductively cycling. In addition, the rates of self-clitoral hold and self-clitoral rub behaviors were significantly higher for 2 of 4 and 4 of 5 of females, respectively, when reproductively cycling. No behavior consistently occurred in association with copulations or with any particular phase in the ovarian cycle. Results from this study suggest that the behaviors tested in this paper can provide some information regarding female spider monkey reproductive state (whether or not she is reproductively cycling), but that they are not indicators of estrus in female spider monkeys. Copyright 2003 Wiley-Liss, Inc.

  14. 24. HAND PAINTING ROOM. FIRST FLOOR HALLWAY, NORTH WING, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. HAND PAINTING ROOM. FIRST FLOOR HALLWAY, NORTH WING, LOOKING WEST. CERAMISTS PAINT GLAZES ONTO BISQUE TILES IN THIS SPACE. THE TECHNIQUE PRODUCES MULTICOLORED TILES. GLAZE KILN No. 2, SHOWING A REBUILT FIREBOX, IS IN THE CENTER OF THE BACKGROUND. - Moravian Pottery & Tile Works, Southwest side of State Route 313 (Swamp Road), Northwest of East Court Street, Doylestown, Bucks County, PA

  15. Quantitative microbial risk assessment of antibacterial hand hygiene products on risk of shigellosis.

    PubMed

    Schaffner, Donald W; Bowman, James P; English, Donald J; Fischler, George E; Fuls, Janice L; Krowka, John F; Kruszewski, Francis H

    2014-04-01

    There are conflicting reports on whether antibacterial hand hygiene products are more effective than nonantibacterial products in reducing bacteria on hands and preventing disease. This research used new laboratory data, together with simulation techniques, to compare the ability of nonantibacterial and antibacterial products to reduce shigellosis risk. One hundred sixtythree subjects were used to compare five different hand treatments: two nonantibacterial products and three antibacterial products, i.e., 0.46% triclosan, 4% chlorhexidine gluconate, or 62% ethyl alcohol. Hands were inoculated with 5.5 to 6 log CFU Shigella; the simulated food handlers then washed their hands with one of the five products before handling melon balls. Each simulation scenario represented an event in which 100 people would be exposed to Shigella from melon balls that had been handled by food workers with Shigella on their hands. Analysis of experimental data showed that the two nonantibacterial treatments produced about a 2-log reduction on hands. The three antibacterial treatments showed log reductions greater than 3 but less than 4 on hands. All three antibacterial treatments resulted in statistically significantly lower concentration on the melon balls relative to the nonantibacterial treatments. A simulation that assumed 1 million Shigella bacteria on the hands and the use of a nonantibacterial treatment predicted that 50 to 60 cases of shigellosis would result (of 100 exposed). Each of the antibacterial treatments was predicted to result in an appreciable number of simulations for which the number of illness cases would be 0, with the most common number of illness cases being 5 (of 100 exposed). These effects maintained statistical significance from 10(6) Shigella per hand down to as low as 100 Shigella per hand, with some evidence to support lower levels. This quantitative microbial risk assessment shows that antibacterial hand treatments can significantly reduce Shigella risk.

  16. The Fine Wire Technique for Flexor Tenolysis

    PubMed Central

    Baltodano, Pablo A.; Weinberg, Maxene H.; Whipple, Lauren A.; Gemmiti, Amanda L.; Whipple, Richard E.

    2017-01-01

    Background: Flexor tenolysis surgery for flexor digitorum profundus and superficialis adhesions is a common procedure performed by hand surgeons. Releasing these adhered tendons can greatly improve hand function and improve quality of life. Recent evidence, however, has shown that the outcomes of tenolysis surgeries are often suboptimal and can result in relapsing adhesions or even tendon ruptures. Methods: This article describes a new technique with potential for reduced complication rates: The Fine Wire Technique for Flexor Tenolysis (FWT). Results: Following FWT, the patient detailed in this article had an excellent recovery of function and no complications: including tendon rupture, infection, hematomas, or any other complications. She reported a major improvement from her preoperative functionality and continues to have this level of success. The wire’s thinness allows for a swift tenolysis. Conclusions: The FWT is a new option available to the hand surgeon associated with good functional results. The wire is readily available to the clinician and is also inexpensive. PMID:29263961

  17. The Fine Wire Technique for Flexor Tenolysis.

    PubMed

    Rosenblum, Matthew K; Baltodano, Pablo A; Weinberg, Maxene H; Whipple, Lauren A; Gemmiti, Amanda L; Whipple, Richard E

    2017-11-01

    Flexor tenolysis surgery for flexor digitorum profundus and superficialis adhesions is a common procedure performed by hand surgeons. Releasing these adhered tendons can greatly improve hand function and improve quality of life. Recent evidence, however, has shown that the outcomes of tenolysis surgeries are often suboptimal and can result in relapsing adhesions or even tendon ruptures. This article describes a new technique with potential for reduced complication rates: The Fine Wire Technique for Flexor Tenolysis (FWT). Following FWT, the patient detailed in this article had an excellent recovery of function and no complications: including tendon rupture, infection, hematomas, or any other complications. She reported a major improvement from her preoperative functionality and continues to have this level of success. The wire's thinness allows for a swift tenolysis. The FWT is a new option available to the hand surgeon associated with good functional results. The wire is readily available to the clinician and is also inexpensive.

  18. Replicating Human Hand Synergies Onto Robotic Hands: A Review on Software and Hardware Strategies.

    PubMed

    Salvietti, Gionata

    2018-01-01

    This review reports the principal solutions proposed in the literature to reduce the complexity of the control and of the design of robotic hands taking inspiration from the organization of the human brain. Several studies in neuroscience concerning the sensorimotor organization of the human hand proved that, despite the complexity of the hand, a few parameters can describe most of the variance in the patterns of configurations and movements. In other words, humans exploit a reduced set of parameters, known in the literature as synergies, to control their hands. In robotics, this dimensionality reduction can be achieved by coupling some of the degrees of freedom (DoFs) of the robotic hand, that results in a reduction of the needed inputs. Such coupling can be obtained at the software level, exploiting mapping algorithm to reproduce human hand organization, and at the hardware level, through either rigid or compliant physical couplings between the joints of the robotic hand. This paper reviews the main solutions proposed for both the approaches.

  19. A Helping Hand.

    ERIC Educational Resources Information Center

    Renner, Jason M.

    2000-01-01

    Discusses how designing a hand washing-friendly environment can help to reduce the spread of germs in school restrooms. Use of electronic faucets, surface risk management, traffic flow, and user- friendly hand washing systems that are convenient and maximally hygienic are examined. (GR)

  20. Water-displacement plethysmography: a technique for the simultaneous thermal manipulation and measurement of whole-hand and whole-foot blood flows.

    PubMed

    Caldwell, Joanne N; Taylor, Nigel A S

    2014-09-01

    The purpose of this project was to design, construct and validate water-displacement plethysmographs for the forearm, hand and foot that could clamp segmental skin temperature whilst simultaneously measuring cutaneous blood flow. Two experiments were performed. In the first, the forearm plethysmograph was validated against a mercury-in-silastic plethysmograph under thermoneutral conditions, with and without forearm heating. Cutaneous vascular conductance was elevated almost three-fold by this treatment, however, there were no significant differences between the two forms of plethysmography in either state (P > 0.05). In study two, hand and foot blood flows were measured under clamped thermoneutral conditions, but with three local skin temperature treatments (5, 25, 40 °C). The hand had significantly higher blood flows than the foot at both 25 °C (4.07 versus 2.20 mL.100 mL( - 1).min( - 1); P < 0.05) and 40 °C (8.20 versus 4.47 mL.100 mL( - 1).min( - 1); P < 0.05). The foot was maximally constricted during the two lower temperatures, yet the cutaneous thermal sensitivity of the hand was almost two-fold greater (P < 0.05). This evidence supports the significant role played by these appendages in heat loss and conservation, and these plethysmographs will now be used to map cutaneous vascular responses (forearm, hand, calf, foot) across combinations of core and local skin temperatures.

  1. [Hand transplantation and implantation of nerve chips. New developments within hand surgery].

    PubMed

    Dahlin, L; Fridén, J; Hagberg, L; Lundborg, G

    1999-10-06

    Injuries and diseases of the hand naturally have an enormous impact on hand function and on quality of life, both occupational and social. The majority of hand-injury patients are under 30 years of age. Hand surgery, an established specialty in Sweden since 1969, is of great importance in terms of clinical developments, education and research. In the coming decade, scientific and clinical advances are to be expected in several fields such as nerve injuries including brachial plexus lesion, microsurgery, flexor tendon injuries and tendon transfer. Bioimplant research and new advances at the biotechnological interface will yield new options in nerve reconstruction, microchip implants in the nervous system, and the restoration of muscle-tendon function following injury. Artificial limbs with advanced motor and sensory functions will be important future aids in the rehabilitation of amputees. Transplantation of human hands is another promising reconstructive procedure which may open up new perspectives in the coming millennium.

  2. [Hand transplantation and implantation of nerve chips. New developments within hand surgery].

    PubMed

    Dahlin, L; Fridén, J; Hagberg, L; Lundborg, G

    2000-03-20

    Injuries and diseases of the hand naturally have an enormous impact on hand function and on quality of life, both occupational and social. The majority of hand-injury patients are under 30 years of age. Hand surgery, an established specialty in Sweden since 1969, is of great importance in terms of clinical developments, education and research. In the coming decade, scientific and clinical advances are to be expected in several fields such as nerve injuries including brachial plexus lesion, microsurgery, flexor tendon injuries and tendon transfer. Bioimplant research and new advances at the biotechnological interface will yield new options in nerve reconstruction, microchip implants in the nervous system, and the restoration of muscle-tendon function following injury. Artificial limbs with advanced motor and sensory functions will be important future aids in the rehabilitation of amputees. Transplantation of human hands is another promising reconstructive procedure which may open iup new perspectives in the coming millennium.

  3. P/2013 P5 PANSTARRS --- a rubbing binary?

    NASA Astrophysics Data System (ADS)

    Hainaut, O.; Snodgrass, C.

    2014-07-01

    disruption is a possible interpretation [15-17]: the peaks of activity would represent the effects of centrifugal landslides and surface readjustments. We propose another process [17]: we suggest that P5 is a small, quasi-contact binary, whose components are either occasionally touching, or settling together into a full-contact binary. The object would then release dust liberated by these repeated low velocity impact, or rather rubbing between its components. Sharma [19] studied the equilibrium of rubble-pile binaries, and concluded that many stable solutions exist for contact and near-contact objects, with a range of prolateness for both components and for a range of shear resistance of the rubble pile. In other words, such an object, if it can be formed, can be stable. Descamp [20] reviewed observations of known binaries in the context of the Roche systems, i.e. fully synchronized binary objects in fluid equilibrium. Several objects appear to be contact binaries, including some very small objects in the same size range as P5, e.g., 2002 NY_40 and 2005 CR_37. Radar observations [21] showed that (69230) Hermes is a fully synchronized binary, with components only slightly larger than P5 (630 and 560 m), separated by a few radii (1200 m). While their formation process is not known, these observations suggest that small, fully synchronized contact binaries do exist. In the case of P5, this hypothesis can be tested observationally, as the 3^{rd} Kepler law indicates that the rotation period of the system should be of several hours, while a rotationally disrupted object should have a period of around 2 h or less. In the mean time, this idea is submitted to ACM.

  4. Grasping with the eyes of your hands: hapsis and vision modulate hand preference.

    PubMed

    Stone, Kayla D; Gonzalez, Claudia L R

    2014-02-01

    Right-hand preference has been demonstrated for visually guided reaching and grasping. Grasping, however, requires the integration of both visual and haptic cues. To what extent does vision influence hand preference for grasping? Is there a hand preference for haptically guided grasping? Two experiments were designed to address these questions. In Experiment 1, individuals were tested in a reaching-to-grasp task with vision (sighted condition) and with hapsis (blindfolded condition). Participants were asked to put together 3D models using building blocks scattered on a tabletop. The models were simple, composed of ten blocks of three different shapes. Starting condition (Vision-First or Hapsis-First) was counterbalanced among participants. Right-hand preference was greater in visually guided grasping but only in the Vision-First group. Participants who initially built the models while blindfolded (Hapsis-First group) used their right hand significantly less for the visually guided portion of the task. To investigate whether grasping using hapsis modifies subsequent hand preference, participants received an additional haptic experience in a follow-up experiment. While blindfolded, participants manipulated the blocks in a container for 5 min prior to the task. This additional experience did not affect right-hand use on visually guided grasping but had a robust effect on haptically guided grasping. Together, the results demonstrate first that hand preference for grasping is influenced by both vision and hapsis, and second, they highlight how flexible this preference could be when modulated by hapsis.

  5. Functional study of hands among patients dialysed for more than 10 years.

    PubMed

    Chazot, C; Chazot, I; Charra, B; Terrat, J C; Vanel, T; Calemard, E; Ruffet, M; Laurent, G

    1993-01-01

    Sixty-six haemodialysed (HD) in centre patients (24 h/m2/week, acetate bath, cuprophane membrane), with a mean age of 59.2 years, treated for 16.7 +/- 4.5 years, underwent clinical examination of their hands to determine anatomical and functional alterations. For each hand a functional score was calculated from a medicolegal technique based on sensitivity and angulation amplitude (rating from 0 to 100). Dialysis-related arthropathy (DRA), including carpal-tunnel (CT) syndrome, was scored as well as hand muscle amyotrophia. Trigger fingers, abnormal synovial hypertrophy, and one or more non-functional tendons were found in 15, 26, and 33% of the patients respectively. Thirteen percent had pseudoporphyria. Amyotrophy was moderate or severe in 39%. The global functional score (mean of the two unilateral functional scores) decreased with time spent on haemodialysis and was correlated with the DRA score. The unilateral functional score was linked to tendinous lesions, amyotrophy, and presence of pulses, but not to CT surgery or presence of AV fistula. Hands with ulnar insult at the elbow shown by electromyography had significantly lower functional scores. Repercussions of hand functional alteration may have an important social and psychological impact in daily life. The responsibility of amyloidosis is evidenced by tendinous lesions and nervous entrapment. Ulnar palsy is also important because of the vital motor role of that nerve in hand function.

  6. Combining heterogenous features for 3D hand-held object recognition

    NASA Astrophysics Data System (ADS)

    Lv, Xiong; Wang, Shuang; Li, Xiangyang; Jiang, Shuqiang

    2014-10-01

    Object recognition has wide applications in the area of human-machine interaction and multimedia retrieval. However, due to the problem of visual polysemous and concept polymorphism, it is still a great challenge to obtain reliable recognition result for the 2D images. Recently, with the emergence and easy availability of RGB-D equipment such as Kinect, this challenge could be relieved because the depth channel could bring more information. A very special and important case of object recognition is hand-held object recognition, as hand is a straight and natural way for both human-human interaction and human-machine interaction. In this paper, we study the problem of 3D object recognition by combining heterogenous features with different modalities and extraction techniques. For hand-craft feature, although it reserves the low-level information such as shape and color, it has shown weakness in representing hiconvolutionalgh-level semantic information compared with the automatic learned feature, especially deep feature. Deep feature has shown its great advantages in large scale dataset recognition but is not always robust to rotation or scale variance compared with hand-craft feature. In this paper, we propose a method to combine hand-craft point cloud features and deep learned features in RGB and depth channle. First, hand-held object segmentation is implemented by using depth cues and human skeleton information. Second, we combine the extracted hetegerogenous 3D features in different stages using linear concatenation and multiple kernel learning (MKL). Then a training model is used to recognize 3D handheld objects. Experimental results validate the effectiveness and gerneralization ability of the proposed method.

  7. Apical extrusion of debris and irrigant using hand and rotary systems: A comparative study

    PubMed Central

    Ghivari, Sheetal B; Kubasad, Girish C; Chandak, Manoj G; Akarte, NR

    2011-01-01

    Aim: To evaluate and compare the amount of debris and irrigant extruded quantitatively by using two hand and rotary nickel–titanium (Ni–Ti) instrumentation techniques. Materials and Methods: Eighty freshly extracted mandibular premolars having similar canal length and curvature were selected and mounted in a debris collection apparatus. After each instrument change, 1 ml of distilled water was used as an irrigant and the amount of irrigant extruded was measured using the Meyers and Montgomery method. After drying, the debris was weighed using an electronic microbalance to determine its weight. Statistical analysis used: The data was analyzed statistically to determine the mean difference between the groups. The mean weight of the dry debris and irrigant within the group and between the groups was calculated by the one-way ANOVA and multiple comparison (Dunnet D) test. Results: The step-back technique extruded a greater quantity of debris and irrigant in comparison to other hand and rotary Ni–Ti systems. Conclusions: All instrumentation techniques extrude debris and irrigant, it is prudent on the part of the clinician to select the instrumentation technique that extrudes the least amount of debris and irrigant, to prevent a flare-up phenomena. PMID:21814364

  8. Motion Control of Drives for Prosthetic Hand Using Continuous Myoelectric Signals

    NASA Astrophysics Data System (ADS)

    Purushothaman, Geethanjali; Ray, Kalyan Kumar

    2016-03-01

    In this paper the authors present motion control of a prosthetic hand, through continuous myoelectric signal acquisition, classification and actuation of the prosthetic drive. A four channel continuous electromyogram (EMG) signal also known as myoelectric signals (MES) are acquired from the abled-body to classify the six unique movements of hand and wrist, viz, hand open (HO), hand close (HC), wrist flexion (WF), wrist extension (WE), ulnar deviation (UD) and radial deviation (RD). The classification technique involves in extracting the features/pattern through statistical time domain (TD) parameter/autoregressive coefficients (AR), which are reduced using principal component analysis (PCA). The reduced statistical TD features and or AR coefficients are used to classify the signal patterns through k nearest neighbour (kNN) as well as neural network (NN) classifier and the performance of the classifiers are compared. Performance comparison of the above two classifiers clearly shows that kNN classifier in identifying the hidden intended motion in the myoelectric signals is better than that of NN classifier. Once the classifier identifies the intended motion, the signal is amplified to actuate the three low power DC motor to perform the above mentioned movements.

  9. Dental Student Hand Hygiene Decreased With Increased Clinical Experience.

    PubMed

    Yaembut, Nanmanas; Ampornaramveth, Ruchanee S; Pisarnturakit, Pagaporn P; Subbalekha, Keskanya

    2016-01-01

    To investigate the effectiveness, related knowledge, attitudes, and practices of hand hygiene (HH) among dental students with different levels of clinical experience. This was a cross-sectional analytical study. Bacterial samples on the participants' hands were obtained using a swab technique before and after handwashing, for oral surgical procedures. After culturing, the colony-forming units were counted. Self-reported questionnaires reflecting the knowledge, attitudes, and practices related to HH were completed by the participants. This study was performed in a primary oral health care institution, Faculty of Dentistry, Chulalongkorn University (Bangkok, Thailand). Bacterial samples and self-reported questionnaires were collected in the Department of Oral and Maxillofacial Surgery. Bacterial culture was performed in the Department of Microbiology. The 120 participants comprised first, second, third-year clinical training students (CTs), and postgraduate dental students (PGs) (32, 34, 30, and 24 participants, respectively). More than 99% of the bacteria were eliminated from the participants' hands after handwashing. Significantly higher numbers of bacteria were recovered from the hands of the PGs compared with those of the CTs, and the hands of the third-year CTs compared with those of the first-year CTs (p < 0.001), after HH. The first-year CTs had the highest attitude scores, whereas the PGs had the lowest practice scores. The knowledge scores were similar in all groups. HH effectiveness, attitudes, and practices of dental students decreased as students gained more clinical experience, whereas knowledge did not. Our results suggest that HH instruction should be given throughout the duration of dental students' education. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  10. Identification of a new EF-hand superfamily member from Trypanosoma brucei

    NASA Technical Reports Server (NTRS)

    Wong, S.; Kretsinger, R. H.; Campbell, D. A.

    1992-01-01

    We identified several open reading frames between the regions encoding calmodulin and ubiquitin-EP52/1 in the genome of Trypanosoma brucei. One of these, EFH5, encodes a protein 192 amino acids long. The EFH5 transcript is present in poly(A)+ mRNA and is present at similar levels in the mammalian bloodstream form and the insect procyclic form. EFH5 contains four EF-hand homolog domains, two of which are inferred to bind Ca2+ ions. We expressed EFH5 as a fusion protein in Escherichia coli and demonstrated calcium-binding activity of the fusion protein using the 45Ca-overlay technique. The function of EFH5 remains unknown; however, as the fourth EF-hand homolog identified in trypanosomes, it attests to the broad range of functions assumed by calcium functioning as a second messenger. EFH5, which is most closely related to LAV1-2 from Physarum, represents a distinct subfamily among the EF-hand-containing proteins.

  11. The Geriatric Hand: Correlation of Hand-Muscle Function and Activity Restriction in Elderly

    ERIC Educational Resources Information Center

    Incel, Nurgul Arinci; Sezgin, Melek; As, Ismet; Cimen, Ozlem Bolgen; Sahin, Gunsah

    2009-01-01

    On the basis of the importance of hand manipulation in activities of daily living (ADL), deterioration of hand function because of various factors reduces quality and independence of life of the geriatric population. The aim of this study was to identify age-induced changes in manual function and to quantify the correlations between hand-muscle…

  12. Verbal Prompting, Hand-over-Hand Instruction, and Passive Observation in Teaching Children with Developmental Disabilities.

    ERIC Educational Resources Information Center

    Biederman, G. B.; Fairhall, J. L.; Raven, K. A.; Davey, V. A.

    1998-01-01

    A study involving six children (ages 5-13) with mental retardation found that overall passive modeling was significantly more effective than hand-over-hand modeling in teaching skills, and that passive modeling was significantly more effective than hand-over-hand modeling with response-contingent verbal prompting. (Author/CR)

  13. Hand controller commonality evaluation process

    NASA Technical Reports Server (NTRS)

    Stuart, Mark A.; Bierschwale, John M.; Wilmington, Robert P.; Adam, Susan C.; Diaz, Manuel F.; Jensen, Dean G.

    1993-01-01

    Hand controller selection for NASA's Orbiter and Space Station Freedom is an important area of human-telerobot interface design and evaluation. These input devices will control remotely operated systems that include large crane-like manipulators (e.g., Remote Manipulator System or RMS), smaller, more dexterous manipulators (e.g., Flight Telerobotic Servicer or FTS), and free flyers (e.g., Orbital Maneuvering Vehicle or OMV). Candidate hand controller configurations for these systems vary in many ways: shape, size, number of degrees-of-freedom (DOF), operating modes, provision of force reflection, range of movement, and 'naturalness' of use. Unresolved design implementation issues remain, including such topics as how the current Orbiter RMS rotational and translational rate hand controllers compare with the proposed Space Station Freedom hand controllers, the advantages that position hand controllers offer for these applications, and whether separate hand controller configurations are required for each application. Since previous studies contain little empirical hand controller task performance data, a controlled study is needed that tests Space Station Freedom candidate hand controllers during representative tasks. This study also needs to include anthropometric and biomechanical considerations.

  14. Individual left-hand and right-hand intra-digit representations in human primary somatosensory cortex.

    PubMed

    Schweisfurth, Meike A; Frahm, Jens; Schweizer, Renate

    2015-09-01

    Individual intra-digit somatotopy of all phalanges of the middle and little finger of the right and left hand was studied by functional magnetic resonance imaging in 12 healthy subjects. Phalanges were tactilely stimulated and activation in BA 3b of the human primary somatosensory cortex could be observed for each individual phalanx. Activation peaks were further analysed using the Direction/Order (DiOr) method, which identifies somatotopy, if a significantly high number of subjects exhibit ordered distal-to-proximal phalanx representions along a similar direction. Based on DiOr, ordered and similar-direction-aligned intra-digit maps across subjects were found at the left hand for the little and middle finger and at the right hand for the little finger. In these digits the proximal phalanges were represented more medially along the course of the central sulcus than the distal phalanges. This is contrasted by the intra-digit maps for the middle finger of the right hand, which showed larger inter-subject variations of phalanx alignments without a similar within-digit representation across subjects. As all subjects were right-handed and as the middle finger of the dominant hand probably plays a more individual role in everyday tactile performance than the little finger of the right hand and all left-hand digits, the observed variation might reflect a functional somatotopy based on individual use of that particular digit at the dominant hand. © 2015 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  15. Hand posture and cognitive control: The congruency sequence effect is reduced near the hands.

    PubMed

    Englert, Julia; Wentura, Dirk

    2016-10-01

    According to several recent articles, attentional processing seems to be modulated by the proximity of one's own hand to a stimulus. Weidler and Abrams (Psychonomic Bulletin & Review, 21, 462-469, 2014) found a significant reduction of the Eriksen flanker effect when the stimuli were presented close to the participants' hands. They interpreted this as evidence for stronger cognitive control near the hands. Using a near-by hands manipulation intended to vary distance while keeping posture of the hands constant, we found a modulation of the congruency sequence effect (CSE or Gratton effect), i.e., a larger flanker effect following incompatible trials than following compatible trials. The CSE was eliminated near the hands. Though we did not find a reduction in the flanker effect itself (which might be the result of using a near-by hand manipulation somewhat different from that of Weidler and Abrams), this result can be considered to be compatible with Weidler and Abrams' original hypothesis if the congruency sequence effect is interpreted in terms of cognitive control.

  16. Dissociable neural responses to hands and non-hand body parts in human left extrastriate visual cortex.

    PubMed

    Bracci, Stefania; Ietswaart, Magdalena; Peelen, Marius V; Cavina-Pratesi, Cristiana

    2010-06-01

    Accumulating evidence points to a map of visual regions encoding specific categories of objects. For example, a region in the human extrastriate visual cortex, the extrastriate body area (EBA), has been implicated in the visual processing of bodies and body parts. Although in the monkey, neurons selective for hands have been reported, in humans it is unclear whether areas selective for individual body parts such as the hand exist. Here, we conducted two functional MRI experiments to test for hand-preferring responses in the human extrastriate visual cortex. We found evidence for a hand-preferring region in left lateral occipitotemporal cortex in all 14 participants. This region, located in the lateral occipital sulcus, partially overlapped with left EBA, but could be functionally and anatomically dissociated from it. In experiment 2, we further investigated the functional profile of hand- and body-preferring regions by measuring responses to hands, fingers, feet, assorted body parts (arms, legs, torsos), and non-biological handlike stimuli such as robotic hands. The hand-preferring region responded most strongly to hands, followed by robotic hands, fingers, and feet, whereas its response to assorted body parts did not significantly differ from baseline. By contrast, EBA responded most strongly to body parts, followed by hands and feet, and did not significantly respond to robotic hands or fingers. Together, these results provide evidence for a representation of the hand in extrastriate visual cortex that is distinct from the representation of other body parts.

  17. Dissociable Neural Responses to Hands and Non-Hand Body Parts in Human Left Extrastriate Visual Cortex

    PubMed Central

    Ietswaart, Magdalena; Peelen, Marius V.; Cavina-Pratesi, Cristiana

    2010-01-01

    Accumulating evidence points to a map of visual regions encoding specific categories of objects. For example, a region in the human extrastriate visual cortex, the extrastriate body area (EBA), has been implicated in the visual processing of bodies and body parts. Although in the monkey, neurons selective for hands have been reported, in humans it is unclear whether areas selective for individual body parts such as the hand exist. Here, we conducted two functional MRI experiments to test for hand-preferring responses in the human extrastriate visual cortex. We found evidence for a hand-preferring region in left lateral occipitotemporal cortex in all 14 participants. This region, located in the lateral occipital sulcus, partially overlapped with left EBA, but could be functionally and anatomically dissociated from it. In experiment 2, we further investigated the functional profile of hand- and body-preferring regions by measuring responses to hands, fingers, feet, assorted body parts (arms, legs, torsos), and non-biological handlike stimuli such as robotic hands. The hand-preferring region responded most strongly to hands, followed by robotic hands, fingers, and feet, whereas its response to assorted body parts did not significantly differ from baseline. By contrast, EBA responded most strongly to body parts, followed by hands and feet, and did not significantly respond to robotic hands or fingers. Together, these results provide evidence for a representation of the hand in extrastriate visual cortex that is distinct from the representation of other body parts. PMID:20393066

  18. Hand assessment in older adults with musculoskeletal hand problems: a reliability study.

    PubMed

    Myers, Helen L; Thomas, Elaine; Hay, Elaine M; Dziedzic, Krysia S

    2011-01-07

    Musculoskeletal hand pain is common in the general population. This study aims to investigate the inter- and intra-observer reliability of two trained observers conducting a simple clinical interview and physical examination for hand problems in older adults. The reliability of applying the American College of Rheumatology (ACR) criteria for hand osteoarthritis to community-dwelling older adults will also be investigated. Fifty-five participants aged 50 years and over with a current self-reported hand problem and registered with one general practice were recruited from a previous health questionnaire study. Participants underwent a standardised, structured clinical interview and physical examination by two independent trained observers and again by one of these observers a month later. Agreement beyond chance was summarised using Kappa statistics and intra-class correlation coefficients. Median values for inter- and intra-observer reliability for clinical interview questions were found to be "substantial" and "moderate" respectively [median agreement beyond chance (Kappa) was 0.75 (range: -0.03, 0.93) for inter-observer ratings and 0.57 (range: -0.02, 1.00) for intra-observer ratings]. Inter- and intra-observer reliability for physical examination items was variable, with good reliability observed for some items, such as grip and pinch strength, and poor reliability observed for others, notably assessment of altered sensation, pain on resisted movement and judgements based on observation and palpation of individual features at single joints, such as bony enlargement, nodes and swelling. Moderate agreement was observed both between and within observers when applying the ACR criteria for hand osteoarthritis. Standardised, structured clinical interview is reliable for taking a history in community-dwelling older adults with self reported hand problems. Agreement between and within observers for physical examination items is variable. Low Kappa values may have resulted

  19. [Complex trauma of the hand].

    PubMed

    Pechlaner, S; Hussl, H

    1998-01-01

    The hand is very exposed to injuries in the daily man's work. The multiple functions of the hand are based on vitality, sensibility, motor function and stability. In severe hand injuries the functional results of the repair are often very poor. In a complex injury of the hand we are faced with the damage of the soft tissue and bone and the loss of vitality and function of the hand. The cause of hand injuries are mainly a crush trauma or the rotating saw. Basically, we recommend an extended primary repair. After the radical debridement we have to reconstruct the damaged structures. We start doing the osteosynthesis and stabilization of the joints. Thereafter, suturing of extensor and flexor tendons. Then, we do the microsurgical reconstructions of vessels and nerves. In case tendons and bones are exposed we have to cover the defect with a pedicled or a free flap. In a long ischemic time we have to change our concept and do the reconstruction of the vessels first. Our results in vitality and sensibility are listed. In the result of a complex hand injury each single functional restoration is very important. Therefore, it is necessary that severe hand injuries are treated at well established centres for hand surgery.

  20. A point prevalence survey on hand hygiene, with a special focus on Candida species.

    PubMed

    Brühwasser, Christina; Hinterberger, Guido; Mutschlechner, Wolfgang; Kaltseis, Josef; Lass-Flörl, Cornelia; Mayr, Astrid

    2016-01-01

    A 1-day point prevalence study evaluated hand hygiene compliance, yeast colonization, and contamination, focusing on the hands of health care workers (HCWs) and patient-oriented surfaces. Hand hygiene compliance was evaluated by applying the direct observation technique and the World Health Organization's compliance program, "My Five Moments for Hand Hygiene." A total of 128 samples from HCWs working in intensive care (n = 11) and intermediate care (n = 2) units and 65 environmental samples from Innsbruck Medical University Hospital were investigated. Hand hygiene compliance was superior for nurses (83.5%) and moderate for medical doctors (45.2%). In general, fungal growth was unique; only 9 of 128 HCW samples and only 4 of 65 environmental samples yielded positive results. The genetic relatedness of yeasts from the same species was investigated by random amplified polymorphic DNA (RAPD) typing. RAPD profiles exhibited the potential for cross-transmission of yeasts. In general, the fungal colonization and contamination rate was low, but a high level of hand hygiene compliance was lacking. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  1. A qualitative analysis of the experience and impact of killing in hand-to-hand combat.

    PubMed

    Jensen, Peter R; Simpson, Duncan

    2014-08-01

    A growing body of research suggests that killing during military combat is closely associated with posttraumatic stress disorder (PTSD), as well as a number of other adverse mental health related conditions (e.g., dissociative experiences, violent behavior, functional impairment). This article provides first-person perspectives on the experiences and impact of killing by service members with the goal of expanding our understanding of the impact of taking a life during war. In audio-recorded phenomenological interviews, 9 service members described their experiences and the subsequent impact of killing during hand-to-hand combat. A description, supported by participant quotations, was constructed to represent the participants' experiences. Results suggest the experience and aftermath of taking a life in hand-to-hand combat was disturbing, psychologically stressful, and necessitated some form of coping after the event. Service members who killed in hand-to-hand combat viewed their actions as necessary to preserve their life and that killing in hand-to-hand combat was more emotionally taxing than killing by shooting. Our findings may help to improve providers' understanding of service members' first-person experiences of killing in hand-to-hand combat and thus provide the basis for the development of a connected and genuine relationship with such military clients. Copyright © 2014 International Society for Traumatic Stress Studies.

  2. OARSI Clinical Trials Recommendations: Hand imaging in clinical trials in osteoarthritis.

    PubMed

    Hunter, D J; Arden, N; Cicuttini, F; Crema, M D; Dardzinski, B; Duryea, J; Guermazi, A; Haugen, I K; Kloppenburg, M; Maheu, E; Miller, C G; Martel-Pelletier, J; Ochoa-Albíztegui, R E; Pelletier, J-P; Peterfy, C; Roemer, F; Gold, G E

    2015-05-01

    Tremendous advances have occurred in our understanding of the pathogenesis of hand osteoarthritis (OA) and these are beginning to be applied to trials targeted at modification of the disease course. The purpose of this expert opinion, consensus driven exercise is to provide detail on how one might use and apply hand imaging assessments in disease modifying clinical trials. It includes information on acquisition methods/techniques (including guidance on positioning for radiography, sequence/protocol recommendations/hardware for MRI); commonly encountered problems (including positioning, hardware and coil failures, sequences artifacts); quality assurance/control procedures; measurement methods; measurement performance (reliability, responsiveness, validity); recommendations for trials; and research recommendations. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  3. Effect of gender and hand laterality on pain processing in human neonates.

    PubMed

    Ozawa, Mio; Kanda, Katsuya; Hirata, Michio; Kusakawa, Isao; Suzuki, Chieko

    2011-01-01

    Previous studies in adults have reported that handedness and gender can affect pain perception. However, it is currently unclear when these differences emerge in human development. Therefore, we examined prefrontal responses to pain stimulation among newborns during their first acute pain experience after birth. Forty newborns at 4-6 days postnatal age were observed during clinically required blood sampling while prefrontal activation was measured with near infrared spectroscopy. Blood sampling in this study was the first experience of a procedure involving skin breaking for these infants. We divided subjects into a right-hand stimulation group (n=21) and a left-hand stimulation group (n=19), depending on whether blood was sampled from the right or the left hand. A three-way analysis of variance (ANOVA) was conducted to examine the effects of several variables on the magnitude of the oxy-Hb value in response to pain stimulus, including stimulus side (right hand or left hand), gender (male or female), recording side (right prefrontal area or left prefrontal area) and interactions between these variables. The data revealed a significant effect of stimulus side (F (1, 72)=9.892, P=0.002), showing that the right-hand stimulation induced a greater prefrontal activation than the left-hand stimulation. No significant gender difference or interactions were found. Our findings suggest that hand laterality affects pain perception even in neonates. However, gender differences in pain perception did not appear to occur during the neonatal period. Further investigations using brain-imaging techniques are required to identify laterality- or gender-related differences in pain processing in humans. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  4. Access to waterless hand sanitizer improves student hand hygiene behavior in primary schools in Nairobi, Kenya.

    PubMed

    Pickering, Amy J; Davis, Jennifer; Blum, Annalise G; Scalmanini, Jenna; Oyier, Beryl; Okoth, George; Breiman, Robert F; Ram, Pavani K

    2013-09-01

    Handwashing is difficult in settings with limited resources and water access. In primary schools within urban Kibera, Kenya, we investigated the impact of providing waterless hand sanitizer on student hand hygiene behavior. Two schools received a waterless hand sanitizer intervention, two schools received a handwashing with soap intervention, and two schools received no intervention. Hand cleaning behavior after toilet use was monitored for 2 months using structured observation. Hand cleaning after toileting was 82% at sanitizer schools (N = 2,507 toileting events), 38% at soap schools (N = 3,429), and 37% at control schools (N = 2,797). Students at sanitizer schools were 23% less likely to have observed rhinorrhea than control students (P = 0.02); reductions in student-reported gastrointestinal and respiratory illness symptoms were not statistically significant. Providing waterless hand sanitizer markedly increased student hand cleaning after toilet use, whereas the soap intervention did not. Waterless hand sanitizer may be a promising option to improve student hand cleansing behavior, particularly in schools with limited water access.

  5. Robotic hand and fingers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salisbury, Curt Michael; Dullea, Kevin J.

    Technologies pertaining to a robotic hand are described herein. The robotic hand includes one or more fingers releasably attached to a robotic hand frame. The fingers can abduct and adduct as well as flex and tense. The fingers are releasably attached to the frame by magnets that allow for the fingers to detach from the frame when excess force is applied to the fingers.

  6. Comparison of ethanol hand sanitizer versus moist towelette packets for mealtime patient hand hygiene.

    PubMed

    Rai, Herleen; Knighton, Shanina; Zabarsky, Trina F; Donskey, Curtis J

    2017-09-01

    To facilitate patient hand hygiene, there is a need for easy-to-use products. In a survey of 100 patients, a single-use ethanol hand sanitizer packet took less time to access than a single-use moist towelette packet (3 vs 23 seconds) and was preferred by 74% of patients for mealtime hand hygiene. Performance of patient hand hygiene increased when a reminder was provided at the time of meal tray delivery. Published by Elsevier Inc.

  7. The left hand doesn't know what the right hand is doing: the disruptive effects of attention to the hands in skilled typewriting.

    PubMed

    Logan, Gordon D; Crump, Matthew J C

    2009-10-01

    Everyone knows that attention to the details disrupts skilled performance, but little empirical evidence documents this fact. We show that attention to the hands disrupts skilled typewriting. We had skilled typists type words preceded by cues that told them to type only the letters assigned to one hand or to type all of the letters. Cuing the hands disrupted performance markedly, slowing typing and increasing the error rate (Experiment 1); these deleterious effects were observed even when no keystrokes were actually inhibited (Experiment 3). However, cuing the same letters with colors was not disruptive (Experiment 2). We account for the disruption with a hierarchical control model, in which an inner loop controls the hands and an outer loop controls what is typed. Typing letters using only one hand requires the outer loop to monitor the inner loop's output; the outer loop slows inner-loop cycle time to increase the likelihood of inhibiting responses with the unwanted hand. This produces the disruption.

  8. Evidence of common and separate eye and hand accumulators underlying flexible eye-hand coordination

    PubMed Central

    Jana, Sumitash; Gopal, Atul

    2016-01-01

    Eye and hand movements are initiated by anatomically separate regions in the brain, and yet these movements can be flexibly coupled and decoupled, depending on the need. The computational architecture that enables this flexible coupling of independent effectors is not understood. Here, we studied the computational architecture that enables flexible eye-hand coordination using a drift diffusion framework, which predicts that the variability of the reaction time (RT) distribution scales with its mean. We show that a common stochastic accumulator to threshold, followed by a noisy effector-dependent delay, explains eye-hand RT distributions and their correlation in a visual search task that required decision-making, while an interactive eye and hand accumulator model did not. In contrast, in an eye-hand dual task, an interactive model better predicted the observed correlations and RT distributions than a common accumulator model. Notably, these two models could only be distinguished on the basis of the variability and not the means of the predicted RT distributions. Additionally, signatures of separate initiation signals were also observed in a small fraction of trials in the visual search task, implying that these distinct computational architectures were not a manifestation of the task design per se. Taken together, our results suggest two unique computational architectures for eye-hand coordination, with task context biasing the brain toward instantiating one of the two architectures. NEW & NOTEWORTHY Previous studies on eye-hand coordination have considered mainly the means of eye and hand reaction time (RT) distributions. Here, we leverage the approximately linear relationship between the mean and standard deviation of RT distributions, as predicted by the drift-diffusion model, to propose the existence of two distinct computational architectures underlying coordinated eye-hand movements. These architectures, for the first time, provide a computational basis for

  9. Hand washing practices in two communities of two states of Eastern India: an intervention study.

    PubMed

    Ray, Sandip Kumar; Zaman, Forhad Akhtar; Laskar, Nasrin Banu

    2010-01-01

    Public health importance of hand washing as well as its importance in reduction of communicable diseases such as diarrhea and acute respiratory infections have been highlighted in many studies worldwide. This study was designed to study the hand washing practices followed in two urban slums as well as to assess and compare the status of different components of hand washing at the pre- and post-intervention phases. A community-based cross-sectional intervention study on hand washing practices was carried out at two urban slums situated in two states of Eastern India with similar sociocultural and linguistic background. The study was carried out by using an interview technique as well as observation of hand washing practices. Interpersonal communication for behavioural change was chosen as a method of intervention. The majority (>90%) practiced hand washing after defecation in both the study areas. However, hand washing following all six steps and for stipulated time period was seen to be poor before intervention. Significant improvement was observed in all the aspects of hand washing after intervention in both the areas. The poor practice of hand washing was observed in some situations and needed attention. Use of soap and clean material for drying hands after hand washing was poor initially followed by improvement after intervention. Based on the findings of the study, it could be suggested that Behaviour Change Communication program should be further planned with emphasis on different components of hand washing with a final objective to bring down the incidence of target diseases.

  10. Evaluation of Dentin Defect Formation during Retreatment with Hand and Rotary Instruments: A Micro-CT Study.

    PubMed

    Yilmaz, Ayca; Helvacioglu-Yigit, Dilek; Gur, Cansu; Ersev, Handan; Kiziltas Sendur, Gullu; Avcu, Egemen; Baydemir, Canan; Abbott, Paul Vincent

    2017-01-01

    The purpose of this study was to compare the incidence and longitudinal propagation of dentin defects after gutta-percha removal with hand and rotary instruments using microcomputed tomography. Twenty mandibular incisors were prepared using the balanced-force technique and scanned in a 19.9  μ m resolution. Following filling with the lateral compaction technique, gutta-percha was removed with ProTaper Universal Retreatment (PTUR) or hand instruments. After rescanning, a total of 24,120 cross-sectional images were analyzed. The numbers, types, and longitudinal length changes of defects were recorded. Defects were observed in 36.90% of the cross sections. A total of 73 defects were comprised of 87.67% craze lines, 2.73% partial cracks, and 9.58% fractures. No significant difference in terms of new defect formation was detected between the retreatment groups. The apical and middle portions of the roots had more dentin defects than the coronal portions. Defects in three roots of the PTUR instrument group increased in length. Under the conditions of this in vitro study, gutta-percha removal seemed to not increase the incidence of dentin defect formation, but the longitudinal defect propagation finding suggests possible cumulative dentinal damage due to additional endodontic procedures. Hand and rotary instrumentation techniques caused similar dentin defect formation during root canal retreatment.

  11. A video-based system for hand-driven stop-motion animation.

    PubMed

    Han, Xiaoguang; Fu, Hongbo; Zheng, Hanlin; Liu, Ligang; Wang, Jue

    2013-01-01

    Stop-motion is a well-established animation technique but is often laborious and requires craft skills. A new video-based system can animate the vast majority of everyday objects in stop-motion style, more flexibly and intuitively. Animators can perform and capture motions continuously instead of breaking them into increments and shooting one still picture per increment. More important, the system permits direct hand manipulation without resorting to rigs, achieving more natural object control for beginners. The system's key component is two-phase keyframe-based capturing and processing, assisted by computer vision techniques. With this system, even amateurs can generate high-quality stop-motion animations.

  12. Reduced asymmetry in motor skill learning in left-handed compared to right-handed individuals.

    PubMed

    McGrath, Robert L; Kantak, Shailesh S

    2016-02-01

    Hemispheric specialization for motor control influences how individuals perform and adapt to goal-directed movements. In contrast to adaptation, motor skill learning involves a process wherein one learns to synthesize novel movement capabilities in absence of perturbation such that they are performed with greater accuracy, consistency and efficiency. Here, we investigated manual asymmetry in acquisition and retention of a complex motor skill that requires speed and accuracy for optimal performance in right-handed and left-handed individuals. We further determined if degree of handedness influences motor skill learning. Ten right-handed (RH) and 10 left-handed (LH) adults practiced two distinct motor skills with their dominant or nondominant arms during separate sessions two-four weeks apart. Learning was quantified by changes in the speed-accuracy tradeoff function measured at baseline and one-day retention. Manual asymmetry was evident in the RH group but not the LH group. RH group demonstrated significantly greater skill improvement for their dominant-right hand than their nondominant-left hand. In contrast, for the LH group, both dominant and nondominant hands demonstrated comparable learning. Less strongly-LH individuals (lower EHI scores) exhibited more learning of their dominant hand. These results suggest that while hemispheric specialization influences motor skill learning, these effects may be influenced by handedness. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Efficacy of stapler versus hand-sewn closure after distal pancreatectomy (DISPACT): a randomised, controlled multicentre trial.

    PubMed

    Diener, Markus K; Seiler, Christoph M; Rossion, Inga; Kleeff, Jörg; Glanemann, Matthias; Butturini, Giovanni; Tomazic, Ales; Bruns, Christiane J; Busch, Olivier R C; Farkas, Stefan; Belyaev, Orlin; Neoptolemos, John P; Halloran, Christopher; Keck, Tobias; Niedergethmann, Marco; Gellert, Klaus; Witzigmann, Helmut; Kollmar, Otto; Langer, Peter; Steger, Ulrich; Neudecker, Jens; Berrevoet, Frederik; Ganzera, Silke; Heiss, Markus M; Luntz, Steffen P; Bruckner, Thomas; Kieser, Meinhard; Büchler, Markus W

    2011-04-30

    The ideal closure technique of the pancreas after distal pancreatectomy is unknown. We postulated that standardised closure with a stapler device would prevent pancreatic fistula more effectively than would a hand-sewn closure of the remnant. This multicentre, randomised, controlled, parallel group-sequential superiority trial was done in 21 European hospitals. Patients with diseases of the pancreatic body and tail undergoing distal pancreatectomy were eligible and were randomly assigned by central randomisation before operation to either stapler or hand-sewn closure of the pancreatic remnant. Surgical performance was assessed with intraoperative photo documentation. The primary endpoint was the combination of pancreatic fistula and death until postoperative day 7. Patients and outcome assessors were masked to group assignment. Interim and final analysis were by intention to treat in all patients in whom a left resection was done. This trial is registered, ISRCTN18452029. Between Nov 16, 2006, and July 3, 2009, 450 patients were randomly assigned to treatment groups (221 stapler; 229 hand-sewn closure), of whom 352 patients (177 stapler, 175 hand-sewn closure) were analysed. Pancreatic fistula rate or mortality did not differ between stapler (56 [32%] of 177) and hand-sewn closure (49 [28%] of 175; OR 0·84, 95% CI 0·53–1·33; p=0·56). One patient died within the fi rst 7 days after surgery in the hand-sewn group; no deaths occurred in the stapler group. Serious adverse events did not differ between groups. Stapler closure did not reduce the rate of pancreatic fistula compared with hand-sewn closure for distal pancreatectomy. New strategies, including innovative surgical techniques, need to be identified to reduce this adverse outcome. German Federal Ministry of Education and Research.

  14. Assessing the manipulative potentials of monkeys, apes and humans from hand proportions: implications for hand evolution.

    PubMed

    Liu, Ming-Jin; Xiong, Cai-Hua; Hu, Di

    2016-11-30

    The hand structure possesses a greater potential for performing manipulative skills than is typically observed, whether in humans or non-human anthropoids. However, a precise assessment of the potential manipulative skills of hands has been challenging, which hampers our understanding of the evolution of manipulative abilities in anthropoid hands. Here, we establish a functional model to quantitatively infer the manipulative potentials of anthropoid hands based on hand proportions. Our results reveal a large disparity of manipulative potentials among anthropoid hands. From the aspect of hand proportions, the human hand has the best manipulative potential among anthropoids. However, the species with a manipulative potential closer to that of humans are not our nearest relatives, chimpanzees, but rather, are certain monkey species. In combination with the phylogenetically informed morphometric analyses, our results suggest that the morphological changes of non-human anthropoid hands did not coevolve with the brain to facilitate the manipulative ability during the evolutionary process, although the manipulative ability is a survival skill. The changes in non-human anthropoid hands may have more likely evolved under selective pressure for locomotion than manipulation. © 2016 The Author(s).

  15. A Low-Tech, Hands-On Approach To Teaching Sorting Algorithms to Working Students.

    ERIC Educational Resources Information Center

    Dios, R.; Geller, J.

    1998-01-01

    Focuses on identifying the educational effects of "activity oriented" instructional techniques. Examines which instructional methods produce enhanced learning and comprehension. Discusses the problem of learning "sorting algorithms," a major topic in every Computer Science curriculum. Presents a low-tech, hands-on teaching method for sorting…

  16. Multi-fingered robotic hand

    NASA Technical Reports Server (NTRS)

    Ruoff, Carl F. (Inventor); Salisbury, Kenneth, Jr. (Inventor)

    1990-01-01

    A robotic hand is presented having a plurality of fingers, each having a plurality of joints pivotally connected one to the other. Actuators are connected at one end to an actuating and control mechanism mounted remotely from the hand and at the other end to the joints of the fingers for manipulating the fingers and passing externally of the robot manipulating arm in between the hand and the actuating and control mechanism. The fingers include pulleys to route the actuators within the fingers. Cable tension sensing structure mounted on a portion of the hand are disclosed, as is covering of the tip of each finger with a resilient and pliable friction enhancing surface.

  17. The impact of an intervention programme employing a hands-on technique to reduce the incidence of anal sphincter tears: interrupted time-series reanalysis.

    PubMed

    Fretheim, Atle; Odgaard-Jensen, Jan; Røttingen, John-Arne; Reinar, Liv Merete; Vangen, Siri; Tanbo, Tom

    2013-10-22

    To re-evaluate previously published findings from an uncontrolled before-after evaluation of an intervention programme to reduce the incidence of anal sphincter tears. A key component of the programme was the use of a hands-on technique where the birth attendant presses the neonate's head during the final stage of delivery while simultaneously supporting the woman's perineum with the other hand. Interrupted time-series analysis using segmented regression modelling. Obstetric departments of five Norwegian hospitals. All women giving births vaginally in the study hospitals, 2002-2008. The main data source was the Medical Birth Registry of Norway. We estimated the change in incidence of anal sphincter tears before and after implementation of the intervention in the five intervention hospitals, taking into account the trends in incidence before and after implementation. Incidence of anal sphincter tears and episiotomies. There were 75 543 registered births at the five included hospitals. We found a 2% absolute reduction in incidence of anal sphincter tears associated with the hospital intervention programme, representing almost a halving in the number of women experiencing serious anal sphincter tears. This is a substantially smaller estimate than previously reported. However, it does represent a highly significant decrease in anal sphincter injuries. The programme was also associated with a significant increase in episiotomies. The intervention programme was associated with a significant reduction in the incidence of obstetric anal sphincter tears. Still, the findings should be interpreted with caution as they seem to contradict the findings from randomised controlled studies of similar interventions.

  18. AUTOMATIC HAND COUNTER

    DOEpatents

    Mann J.R.; Wainwright, A.E.

    1963-06-11

    An automatic, personnel-operated, alpha-particle hand monitor is described which functions as a qualitative instrument to indicate to the person using it whether his hands are cold'' or hot.'' The monitor is activated by a push button and includes several capacitor-triggered thyratron tubes. Upon release of the push button, the monitor starts the counting of the radiation present on the hands of the person. If the count of the radiation exceeds a predetermined level within a predetermined time, then a capacitor will trigger a first thyratron tube to light a hot'' lamp. If, however, the count is below such level during this time period, another capacitor will fire a second thyratron to light a safe'' lamp. (AEC)

  19. Access to Waterless Hand Sanitizer Improves Student Hand Hygiene Behavior in Primary Schools in Nairobi, Kenya

    PubMed Central

    Pickering, Amy J.; Davis, Jennifer; Blum, Annalise G.; Scalmanini, Jenna; Oyier, Beryl; Okoth, George; Breiman, Robert F.; Ram, Pavani K.

    2013-01-01

    Handwashing is difficult in settings with limited resources and water access. In primary schools within urban Kibera, Kenya, we investigated the impact of providing waterless hand sanitizer on student hand hygiene behavior. Two schools received a waterless hand sanitizer intervention, two schools received a handwashing with soap intervention, and two schools received no intervention. Hand cleaning behavior after toilet use was monitored for 2 months using structured observation. Hand cleaning after toileting was 82% at sanitizer schools (N = 2,507 toileting events), 38% at soap schools (N = 3,429), and 37% at control schools (N = 2,797). Students at sanitizer schools were 23% less likely to have observed rhinorrhea than control students (P = 0.02); reductions in student-reported gastrointestinal and respiratory illness symptoms were not statistically significant. Providing waterless hand sanitizer markedly increased student hand cleaning after toilet use, whereas the soap intervention did not. Waterless hand sanitizer may be a promising option to improve student hand cleansing behavior, particularly in schools with limited water access. PMID:23836575

  20. Smart Hand For Manipulators

    NASA Astrophysics Data System (ADS)

    Fiorini, Paolo

    1987-10-01

    Sensor based, computer controlled end effectors for mechanical arms are receiving more and more attention in the robotics industry, because commonly available grippers are only adequate for simple pick and place tasks. This paper describes the current status of the research at JPL on a smart hand for a Puma 560 robot arm. The hand is a self contained, autonomous system, capable of executing high level commands from a supervisory computer. The mechanism consists of parallel fingers, powered by a DC motor, and controlled by a microprocessor embedded in the hand housing. Special sensors are integrated in the hand for measuring the grasp force of the fingers, and for measuring forces and torques applied between the arm and the surrounding environment. Fingers can be exercised under position, velocity and force control modes. The single-chip microcomputer in the hand executes the tasks of communication, data acquisition and sensor based motor control, with a sample cycle of 2 ms and a transmission rate of 9600 baud. The smart hand described in this paper represents a new development in the area of end effector design because of its multi-functionality and autonomy. It will also be a versatile test bed for experimenting with advanced control schemes for dexterous manipulation.