Sample records for hand transmitted vibration

  1. [Occupational exposure to hand-transmitted vibration in Poland].

    PubMed

    Harazin, Barbara; Zieliński, Grzegorz

    2004-01-01

    Occupational exposure to hand transmitted vibration may cause disorders in upper extremities known as hand-arm vibration syndrome. Therefore it is essential to know the sources of vibration, occupational groups exposed to vibration and the number of exposed workers. The aim of the study was to estimate the number of men and women exposed to hand-transmitted vibration in Poland. The completed questionnaires were obtained from 265 (80%) sanitary inspection stations. They included questions on: the name of workplaces, the name and the type of vibration sources, workers' gender, the number of workers exposed to vibration, indicating the extent of exposure measured against the three threshold limit values (< 0.5 TLV; 0.5 < TLV < 1 and > 1 TLV), and the number of workers exposed to hand-transmitted vibration not documented by measurements in a particular workplaces, indicating one of the three possible kinds of exposure (occasional, periodical and constant). The questionnaire data were based on measurements and analyses performed in 1997-2000. The results of the study showed that vibrating tools used by grinders, fitters, locksmiths, rammers, road workers, carpenters and smiths proved to be the most frequent sources of hand-transmitted vibration. It was revealed that 78.6% of operators of these tools were exposed to vibration exceeding 1 TLV. The study also indicated that 17,000 workers, including 1700 women, were exposed to vibration exceeding the threshold limit values.

  2. Reduction in finger blood flow induced by hand-transmitted vibration: effect of hand elevation.

    PubMed

    Ye, Ying; Mauro, Marcella; Bovenzi, Massimo; Griffin, Michael J

    2015-10-01

    This study investigated the effect of hand elevation on reductions in finger blood flow (FBF) induced by hand-transmitted vibration. Fourteen males attended six sessions on six separate days, with a control sessions and a vibration session (125-Hz vibration at 44 ms(-2) rms) with the right hand supported at each of three elevations: 20 cm below heart level (HL), at HL, and 20 cm above HL. Finger blood flow on the left and right hand was measured every 30 s during each 25-min session comprised of five periods: (1) no force and no vibration (5 min), (2) 2-N force and no vibration (5 min), (3) 2-N force and vibration (5 min), (4) 2-N force and no vibration (5 min), and (5) no force and no vibration (5 min). Without vibration, FBF decreased with increasing elevation of the hand. During vibration of the right hand, FBF reduced on both hands. With elevation of the right hand, the percentage reduction in FBF due to vibration (relative to FBF on the same finger at the same elevation before exposure to vibration) was similar on the middle and little fingers of both hands. After cessation of vibration, there was delayed return of FBF with all three hand heights. Vibration of one hand reduces FBF on both exposed and unexposed hands, with the reduction dependent on the elevation of the hand. The mechanisms responsible for vibration-induced reductions in FBF seem to reduce blood flow as a percentage of the blood flow without vibration. Tasks requiring the elevation of the hands will be associated with lower FBF, and the FBF will be reduced further if there is exposure to hand-transmitted vibration.

  3. Hand-transmitted vibration and biodynamic response of the human hand-arm: a critical review.

    PubMed

    Dong, R G; Rakheja, S; Schopper, A W; Han, B; Smutz, W P

    2001-01-01

    Hand-arm vibration syndrome (HAVS) has been associated with prolonged exposure to vibration transmitted to the human hand-arm system from hand-held power tools, vibrating machines, or hand-held vibrating workpieces. The biodynamic response of the human hand and arm to hand transmitted vibration (HTV) forms an essential basis for effective evaluations of exposures, vibration-attenuation mechanisms, and potential injury mechanisms. The biodynamic response to HTV and its relationship to HAVS are critically reviewed and discussed to highlight the advances and the need for further research. In view of its strong dependence on the nature of HTV and the lack of general agreement on the characteristics of HTV, the reported studies are first reviewed to enhance an understanding of HTV and related issues. The characteristics of HTV and relevant unresolved issues are discussed on the basis of measured data, proposed standards, and measurement methods, while the need for further developments in measurement systems is emphasized. The studies on biodynamic response and their findings are grouped into four categories based on the methodology used and the objective. These include studies on (1) through-the-hand-arm response, expressed in terms of vibration transmissibility; (2) to-the-hand response, expressed in terms of the force-motion relationship of the hand-arm system; (3) to-the-hand biodynamic response function, expressed in terms of vibration energy absorption; and (4) computer modeling of the biodynamic response characteristics.

  4. Epidemiological evidence for new frequency weightings of hand-transmitted vibration.

    PubMed

    Bovenzi, Massimo

    2012-01-01

    This paper provides an overview of the exposure-response relationship for the vascular component of the hand-arm vibration syndrome, called vibration-induced white finger (VWF). Over the past two decades, several epidemiological studies have shown a poor agreement between the risk for VWF observed in various occupational groups and that predicted by models included in annexes to International Standard ISO 5349 (ISO 5349:1986, ISO 5349-1:2001). Either overestimation or underestimation of the occurrence of VWF have been reported by investigators. It has been argued that the current ISO frequency-weighting curve for hand-transmitted vibration, which assumes that vibration-induced adverse health effects are inversely related to the frequency of vibration between 16 and 1250 Hz, may be unsuitable for the assessment of VWF. To investigate this issue, a prospective cohort study was carried out to explore the performance of four alternative frequency weightings for hand-transmitted vibration to predict the incidence of VWF in groups of forestry and stone workers. The findings of this study suggested that measures of vibration exposure which give relatively more weight to intermediate and high frequency vibration produced better predictions of the incidence of VWF than that obtained with the frequency weighting currently recommended in International Standard ISO 5349-1:2001.

  5. Evaluating the effectiveness of gloves in reducing the hazards of hand-transmitted vibration.

    PubMed

    Griffin, M J

    1998-05-01

    A method of evaluating the effectiveness of gloves in reducing the hazards of hand-transmitted vibration is proposed. The glove isolation effectiveness was calculated from: (a) the measured transmissibility of a glove, (b) the vibration spectrum on the handle of a specific tool (or class of tools), and (c) the frequency weighting indicating the degree to which different frequencies of vibration cause injury. With previously reported tool vibration spectra and glove transmissibilities (from 10-1000 Hz), the method was used to test 10 gloves with 20 different powered tools. The frequency weighting for hand-transmitted vibration advocated in British standard 6842 (1987) and international standard 5349 (1986) greatly influences the apparent isolation effectiveness of gloves. With the frequency weighting, the gloves had little effect on the transmission of vibration to the hand from most of the tools. Only for two or three tools (those dominated by high frequency vibration) did any glove provide useful attenuation. Without the frequency weighting, some gloves showed useful attenuation of the vibration on most powered tools. In view of the uncertain effect of the vibration frequency in the causation of disorders from hand-transmitted vibration, it is provisionally suggested that the wearing of a glove by the user of a particular vibratory tool could be encouraged if the glove reduces the transmission of vibration when it is evaluated without the frequency weighting and does not increase the vibration when it is evaluated with the frequency weighting. A current international standard for the measurement and evaluation of the vibration transmitted by gloves can classify a glove as an antivibration glove when it provides no useful attenuation of vibration, whereas a glove providing useful attenuation of vibration on a specific tool can fail the test.

  6. Vibrations transmitted from human hands to upper arm, shoulder, back, neck, and head.

    PubMed

    Xu, Xueyan S; Dong, Ren G; Welcome, Daniel E; Warren, Christopher; McDowell, Thomas W; Wu, John Z

    2017-12-01

    Some powered hand tools can generate significant vibration at frequencies below 25 Hz. It is not clear whether such vibration can be effectively transmitted to the upper arm, shoulder, neck, and head and cause adverse effects in these substructures. The objective of this study is to investigate the vibration transmission from the human hands to these substructures. Eight human subjects participated in the experiment, which was conducted on a 1-D vibration test system. Unlike many vibration transmission studies, both the right and left hand-arm systems were simultaneously exposed to the vibration to simulate a working posture in the experiment. A laser vibrometer and three accelerometers were used to measure the vibration transmitted to the substructures. The apparent mass at the palm of each hand was also measured to help in understanding the transmitted vibration and biodynamic response. This study found that the upper arm resonance frequency was 7-12 Hz, the shoulder resonance was 7-9 Hz, and the back and neck resonances were 6-7 Hz. The responses were affected by the hand-arm posture, applied hand force, and vibration magnitude. The transmissibility measured on the upper arm had a trend similar to that of the apparent mass measured at the palm in their major resonant frequency ranges. The implications of the results are discussed. Musculoskeletal disorders (MSDs) of the shoulder and neck are important issues among many workers. Many of these workers use heavy-duty powered hand tools. The combined mechanical loads and vibration exposures are among the major factors contributing to the development of MSDs. The vibration characteristics of the body segments examined in this study can be used to help understand MSDs and to help develop more effective intervention methods.

  7. Vibrations transmitted from human hands to upper arm, shoulder, back, neck, and head

    PubMed Central

    Xu, Xueyan S.; Dong, Ren G.; Welcome, Daniel E.; Warren, Christopher; McDowell, Thomas W.; Wu, John Z.

    2016-01-01

    Some powered hand tools can generate significant vibration at frequencies below 25 Hz. It is not clear whether such vibration can be effectively transmitted to the upper arm, shoulder, neck, and head and cause adverse effects in these substructures. The objective of this study is to investigate the vibration transmission from the human hands to these substructures. Eight human subjects participated in the experiment, which was conducted on a 1-D vibration test system. Unlike many vibration transmission studies, both the right and left hand-arm systems were simultaneously exposed to the vibration to simulate a working posture in the experiment. A laser vibrometer and three accelerometers were used to measure the vibration transmitted to the substructures. The apparent mass at the palm of each hand was also measured to help in understanding the transmitted vibration and biodynamic response. This study found that the upper arm resonance frequency was 7–12 Hz, the shoulder resonance was 7–9 Hz, and the back and neck resonances were 6–7 Hz. The responses were affected by the hand-arm posture, applied hand force, and vibration magnitude. The transmissibility measured on the upper arm had a trend similar to that of the apparent mass measured at the palm in their major resonant frequency ranges. The implications of the results are discussed. Relevance to industry Musculoskeletal disorders (MSDs) of the shoulder and neck are important issues among many workers. Many of these workers use heavy-duty powered hand tools. The combined mechanical loads and vibration exposures are among the major factors contributing to the development of MSDs. The vibration characteristics of the body segments examined in this study can be used to help understand MSDs and to help develop more effective intervention methods. PMID:29123326

  8. Negligent exposures to hand-transmitted vibration.

    PubMed

    Griffin, Michael J

    2008-04-01

    If the negligence of an employer results in the disability in an employee, the employer is responsible, in whole or in part, for the disability. The employer is wholly responsible when the worker would not have developed the disability if the employer had taken all reasonable preventative measures. The employer is only partly responsible if the worker would probably have developed some disability even if the employer had taken all reasonable precautions. The employer's responsibility may be estimated from the difference between the actual disability of the worker and the disability that the worker would have suffered if the employer had taken all reasonable preventative measures. This paper considers alternative ways of apportioning negligent and non-negligent exposures to hand-transmitted vibration. The equivalent daily vibration exposure, A(8), used in current EU Directives is shown to be unsuitable for distinguishing between the consequences of negligent and non-negligent exposures because the risks of developing a disorder from hand-transmitted vibration also depend on the years of exposure. Furthermore, daily exposures take no account of individual susceptibility or the practicality of reducing exposure. The consequences of employer negligence may be estimated from the delay in the onset and progression of disorder that would have been achieved if the employer had acted reasonably, such as by reducing vibration magnitude and exposure duration to the minimum that was reasonably achievable in the circumstances. This seems to be fair and reasonable for both employers and employees and indicates the consequences of negligence-the period of the worker's life with disease as a result of negligence and the period for which their employment opportunities may be restricted as a result of the onset of the disorder due to negligence. The effects of negligence may be estimated from the delay in the onset of disease or disability that would have occurred if the employer

  9. Dose-response relationship between hand-transmitted vibration and hand-arm vibration syndrome in a tropical environment.

    PubMed

    Su, Anselm Ting; Maeda, Setsuo; Fukumoto, Jin; Darus, Azlan; Hoe, Victor C W; Miyai, Nobuyuki; Isahak, Marzuki; Takemura, Shigeki; Bulgiba, Awang; Yoshimasu, Kouichi; Miyashita, Kazuhisa

    2013-07-01

    The dose-response relationship for hand-transmitted vibration has been investigated extensively in temperate environments. Since the clinical features of hand-arm vibration syndrome (HAVS) differ between the temperate and tropical environment, we conducted this study to investigate the dose-response relationship of HAVS in a tropical environment. A total of 173 male construction, forestry and automobile manufacturing plant workers in Malaysia were recruited into this study between August 2011 and 2012. The participants were interviewed for history of vibration exposure and HAVS symptoms, followed by hand functions evaluation and vibration measurement. Three types of vibration doses-lifetime vibration dose (LVD), total operating time (TOT) and cumulative exposure index (CEI)-were calculated and its log values were regressed against the symptoms of HAVS. The correlation between each vibration exposure dose and the hand function evaluation results was obtained. The adjusted prevalence ratio for finger tingling and numbness was 3.34 (95% CI 1.27 to 8.98) for subjects with lnLVD≥20 ln m(2) s(-4) against those <16 ln m(2) s(-4). Similar dose-response pattern was found for CEI but not for TOT. No subject reported white finger. The prevalence of finger coldness did not increase with any of the vibration doses. Vibrotactile perception thresholds correlated moderately with lnLVD and lnCEI. The dose-response relationship of HAVS in a tropical environment is valid for finger tingling and numbness. The LVD and CEI are more useful than TOT when evaluating the dose-response pattern of a heterogeneous group of vibratory tools workers.

  10. [Influence of two positions for measuring instrument adapter on measurement of hand-transmitted vibration in grinding machine].

    PubMed

    Xie, X S; Zhang, M; Zheng, Y D; Du, X Y; Qi, C

    2016-06-20

    To investigate the influence of two positions for measuring instrument adapter on the measurement of hand-transmitted vibration in grinding machine using the intraclass correlation coefficient (ICC) of reliability assessment index, and to provide a basis for studies on the measurement standard for hand-transmitted vibration. With reference to the measurement standard for hand-transmitted vibration ISO 5349 Mechanical vibration-Measurement and evaluation of human exposure to hand-transmitted vibration-Part 1: General requirements and Mechanical vibration-Measurement and evaluation of human exposure to hand-transmitted vibration-Part 2: Practical guidance for measurement at the workplace, the domestic AWA5936 hand-transmitted vibration measuring instrument and SVAN-106 hand-transmitted vibration measuring instrument from Poland were used to measure hand-transmitted vibration in 3 workers for grinding machine in a foundry for 5 days continuously from September to October, 2014, and Y-axis data were recorded and compared. In worker A, the "T" -shaped adapter had a significantly higher mean Y-axis accelerated speed effective value than the "O" -shaped adapter [4.34 m/s(2) (95%CI 4.05(-)4.63) vs 2.32 m/s(2) (95%CI 2.27~2.38) , t=13.781, P<0.01]. In workers B and C, AWA5936 "U" -shaped adapter (placed at the position of the handle of grinding machine) had lower degrees of data variation of 12.55% and 15.77%, respectively, suggesting good data stability. The measurement results showed significant differences across different positions of adapter (P<0.01) and between all adapters except "O" -shaped and line-shaped adapters (all P<0.01) , while the measurement results showed no significant differences between the "O" -shaped and line-shaped adapters (P>0.01). The comparison of the measurement results of AWA5936 vibration measuring instrument with an "U" -shaped adapter and SVAN-106 vibration measuring instrument with an "S" -shaped adapter showed an ICC of >0.80 (ICC=0

  11. [Measurement and analysis of hand-transmitted vibration of vibration tools in workplace for automobile casting and assembly].

    PubMed

    Xie, X S; Qi, C; Du, X Y; Shi, W W; Zhang, M

    2016-02-20

    To investigate the features of hand-transmitted vibration of common vibration tools in the workplace for automobile casting and assembly. From September to October, 2014, measurement and spectral analysis were performed for 16 typical hand tools(including percussion drill, pneumatic wrench, grinding machine, internal grinder, and arc welding machine) in 6 workplaces for automobile casting and assembly according to ISO 5349-1-2001 Mechanical vibration-Measurement and evaluation of human exposure to hand-transmitted vibration-part 1: General requirements and ISO 5349-2-2001 Mechanical vibration-Measurement and evaluation of human exposure to hand-transmitted vibration-Part 2: Practical guidance for measurement in the workplace. The vibration acceleration waveforms of shearing machine, arc welding machine, and pneumatic wrench were mainly impact wave and random wave, while those of internal grinder, angle grinder, percussion drill, and grinding machine were mainly long-and short-period waves. The daily exposure duration to vibration of electric wrench, pneumatic wrench, shearing machine, percussion drill, and internal grinder was about 150 minutes, while that of plasma cutting machine, angle grinder, grinding machine, bench grinder, and arc welding machine was about 400 minutes. The range of vibration total value(ahv) was as follows: pneumatic wrench 0.30~11.04 m/s(2), grinding wheel 1.61~8.97 m/s(2), internal grinder 1.46~8.70 m/s(2), percussion drill 11.10~14.50 m/s(2), and arc welding machine 0.21~2.18 m/s(2). The workers engaged in cleaning had the longest daily exposure duration to vibration, and the effective value of 8-hour energy-equivalent frequency-weighted acceleration for them[A(8)] was 8.03 m/s(2), while this value for workers engaged in assembly was 4.78 m/s(2). The frequency spectrogram with an 1/3-time frequency interval showed that grinding machine, angle grinder, and percussion drill had a high vibration acceleration, and the vibration limit curve

  12. Prevalence of Hand-transmitted Vibration Exposure among Grass-cutting Workers using Objective and Subjective Measures

    NASA Astrophysics Data System (ADS)

    Azmir, N. A.; Yahya, M. N.

    2017-01-01

    Extended exposure to hand-transmitted vibration from vibrating machine is associated with an increased occurrence of symptoms of occupational disease related to hand disorder. The present case study is to determine the prevalence and correlation of significant subjective as well as objective variables that induce to hand arm vibration syndrome (HAVS) among hand-held grass-cutting workers in Malaysia. Thus, recommendations are made for grass-cutting workers and grass maintenance service management based on findings. A cross sectional study using adopted subjective Hand Arm Vibration Exposure Risk Assessment (HAVERA) questionnaire from Vibration Injury Network on hand disorder signs and symptoms was distributed to a sample of one hundred and sixty eight male workers from grass and turf maintenance industry that use vibrating machine as part of their work. For objective measure, hand-transmitted vibration measurement was collected on site during operation by the following ISO 5349-1, 2001. Two groups were identified in this research comprising of high exposure group and low-moderate exposure group. Workers also gave information about their personal identification, social history, workers’ health, occupational history and machine safety inspection. There was positive HAVS symptoms relationship between the low-moderate exposure group and high exposure group among hand-held grass-cutting workers. The prevalence ratio (PR) was considered high for experiencing white colour change at fingers and fingers go numb which are 3.63 (1.41 to 9.39) and 4.24 (2.18 to 8.27), respectively. The estimated daily vibration exposure, A(8) differs between 2.1 to 20.7 ms-2 for right hand while 2.7 to 29.1 ms-2 for left hand. The subjects claimed that the feel of numbness at left hand is much stronger compared to right hand. The results suggest that HAVS is diagnosed in Malaysia especially in agriculture sector. The A(8) indicates that the exposure value is more than exposure limit value

  13. Assessment of hand-transmitted vibration exposure from motorized forks used for beach-cleaning operations.

    PubMed

    McDowell, Thomas W; Welcome, Daniel E; Warren, Christopher; Xu, Xueyan S; Dong, Ren G

    2013-01-01

    Motorized vibrating manure forks were used in beach-cleaning operations following the massive Deepwater Horizon oil spill in the Gulf of Mexico during the summer of 2010. The objectives of this study were to characterize the vibration emissions of these motorized forks and to provide a first approximation of hand-transmitted vibration exposures to workers using these forks for beach cleaning. Eight operators were recruited to operate the motorized forks during this laboratory study. Four fork configurations were used in the study; two motor speeds and two fork basket options were evaluated. Accelerations were measured near each hand as the operators completed the simulated beach-cleaning task. The dominant vibration frequency for these tools was identified to be around 20 Hz. Because acceleration was found to increase with motor speed, workers should consider operating these tools with just enough speed to get the job done. These forks exhibited considerable acceleration magnitudes when unloaded. The study results suggest that the motor should not be operated with the fork in the unloaded state. Anti-vibration gloves are not effective at attenuating the vibration frequencies produced by these forks, and they may even amplify the transmitted vibration and increase hand/arm fatigue. While regular work gloves are suitable, vibration-reducing gloves may not be appropriate for use with these tools. These considerations may also be generally applicable for the use of motorized forks in other workplace environments.

  14. [Assessment of energy and macronutrients supply in daily food rations of people exposed to hand transmitted vibrations].

    PubMed

    Zabłocka-Słowińska, Katarzyna; Limburska, Joanna; Prescha, Anna; Pieczyńska, Joanna; Tomczyk, Jarosław; Grajeta, Halina

    2011-01-01

    Occupational exposure of workers to mechanical hand transmitted vibrations may result in the development of nonspecific lesions. Balanced diet is one of factors that protect human organism against abnormalities resulting from occupational exposure. The aim of this study was to assess the supply of energy and macronutrients in daily food rations (DFR) of people exposed to hand transmitted vibration. Eighty workers, including 37 men (mean age 44.6 years) and 43 women (mean age 44 years) exposed to hand transmitted vibrations were recruited in this study. Of those, 72 people worked in crystal glassworks as glass cutters, 5 people were physiotherapists and 3 were woodcutters. For all workers, there was measured exposure to hand transmitted vibration. Nutritional status was assessed using 24-hour dietary recall; the procedure was repeated 3 times. The results of the nutritional assessment were compared with recommended daily allowances (RDA) for energy, protein, minerals and vitamins, total carbohydrates, total fat, saturated fatty acids (SFA), monounsaturated fatty acids (MUFA), polyunsaturated fatty acids (PUFA), cholesterol and dietary fibre. The average intake of energy in daily food rations of the women was too low while men received the appropriate amount of energy. Average protein intake by men and women was higher than the relevant RDA. The average amount of carbohydrates received by the surveyed women and men were too low, just as the consumption of PUFA, dietary fibre, potassium and calcium. We also found an excessive, average supply of total fat, MUFA, SFA, cholesterol and most of the vitamins with the DFR of the women and men. The nutrition in the group of workers exposed to hand transmitted vibration was found to be imbalanced due to excessive intakes of total fat, saturated fatty acids and cholesterol combined with insufficient consumption of carbohydrates, dietary fibres, potassium and calcium. The co-occurrence of vibration and imbalanced diet may

  15. The study on hand-arm vibration syndrome in China.

    PubMed

    Lin, Wang; Chunzhi, Zhang; Qiang, Zhang; Kai, Zhang; Xiaoli, Zeng

    2005-07-01

    To review the main achievement and problems of study on hand-arm vibration syndrome in China. The epidemiological and clinical study indicate that HAVS was reported from almost provinces in China, the prevalence of VWF ranges from 2.5% to 82.8% in the workers with vibrating tool use. The exposure-response relationship between prevalence of VWF and intensity and duration of exposed to hand-transmitted vibration has confirmed. Diagnostic criteria of HAVS has been established and performed by Chinese government in 1985, and it was revised by government as a national standard for occupational health in 2002. The "hygienic standard for hand-transmitted vibration in workplace" as a national standard and the "methods of measurement and assessment for hand-transmitted vibration" as a recommend standard were published by government also. The limited value of exposed to hand-arm vibration was 5.0 m/s2 that is energy equivalent frequency-weighted acceleration for a period of 4 h (ahw(4)). There are some problems in this field of China need to further study in the future.

  16. Haemodynamic changes in ipsilateral and contralateral fingers caused by acute exposures to hand transmitted vibration.

    PubMed Central

    Bovenzi, M; Griffin, M J

    1997-01-01

    OBJECTIVES: To investigate changes in digital circulation during and after exposure to hand transmitted vibration. By studying two frequencies and two magnitudes of vibration, to investigate the extent to which haemodynamic changes depend on the vibration frequency, the vibration acceleration, and the vibration velocity. METHODS: Finger skin temperature (FST), finger blood flow (FBF), and finger systolic pressure were measured in the fingers of both hands in eight healthy men. Indices of digital vasomotor tone-such as critical closing pressure and vascular resistance-were estimated by pressure-flow curves obtained with different hand heights. With a static load of 10 N, the right hand was exposed for 30 minutes to each of the following root mean squared (rms) acceleration magnitudes and frequencies of vertical vibration: 22 m.s-2 at 31.5 Hz, 22 m.s-2 at 125 Hz, and 87 m.s-2 at 125 Hz. A control condition consisted of exposure to the static load only. The measures of digital circulation and vasomotor tone were taken before exposure to the vibration and the static load, and at 0, 20, 40, and 60 minutes after the end of each exposure. RESULTS: Exposure to static load caused no significant changes in FST, FBF, or indices of vasomotor tone in either the vibrated right middle finger or the non-vibrated left middle finger. In both fingers, exposure to vibration of 125 Hz and 22 m.s-2 produced a greater reduction in FBF and a greater increase in vasomotor tone than did vibration of 31.5 Hz and 22 m.s-2. In the vibrated right finger, exposure to vibration of 125 Hz and 87 m.s-2 provoked an immediate vasodilation which was followed by vasoconstriction during recovery. The non-vibrated left finger showed a significant increase in vasomotor tone throughout the 60 minute period after the end of vibration exposure. CONCLUSIONS: The digital circulatory response to acute vibration depends upon the magnitude and frequency of the vibration stimulus. Vasomotor mechanisms, mediated

  17. Tool-specific performance of vibration-reducing gloves for attenuating fingers-transmitted vibration

    PubMed Central

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.

    2016-01-01

    BACKGROUND Fingers-transmitted vibration can cause vibration-induced white finger. The effectiveness of vibration-reducing (VR) gloves for reducing hand transmitted vibration to the fingers has not been sufficiently examined. OBJECTIVE The objective of this study is to examine tool-specific performance of VR gloves for reducing finger-transmitted vibrations in three orthogonal directions (3D) from powered hand tools. METHODS A transfer function method was used to estimate the tool-specific effectiveness of four typical VR gloves. The transfer functions of the VR glove fingers in three directions were either measured in this study or during a previous study using a 3D laser vibrometer. More than seventy vibration spectra of various tools or machines were used in the estimations. RESULTS When assessed based on frequency-weighted acceleration, the gloves provided little vibration reduction. In some cases, the gloves amplified the vibration by more than 10%, especially the neoprene glove. However, the neoprene glove did the best when the assessment was based on unweighted acceleration. The neoprene glove was able to reduce the vibration by 10% or more of the unweighted vibration for 27 out of the 79 tools. If the dominant vibration of a tool handle or workpiece was in the shear direction relative to the fingers, as observed in the operation of needle scalers, hammer chisels, and bucking bars, the gloves did not reduce the vibration but increased it. CONCLUSIONS This study confirmed that the effectiveness for reducing vibration varied with the gloves and the vibration reduction of each glove depended on tool, vibration direction to the fingers, and finger location. VR gloves, including certified anti-vibration gloves do not provide much vibration reduction when judged based on frequency-weighted acceleration. However, some of the VR gloves can provide more than 10% reduction of the unweighted vibration for some tools or workpieces. Tools and gloves can be matched for

  18. Hand-arm vibration in orthopaedic surgery: a neglected risk.

    PubMed

    Mahmood, F; Ferguson, K B; Clarke, J; Hill, K; Macdonald, E B; Macdonald, D J M

    2017-12-30

    Hand-arm vibration syndrome is an occupational disease caused by exposure to hand-arm transmitted vibration. The Health and Safety Executive has set limits for vibration exposure, including an exposure action value (EAV), where steps should be taken to reduce exposure, and an exposure limit value (ELV), beyond which vibrating equipment must not be used for the rest of the working day. To measure hand-arm transmitted vibration among orthopaedic surgeons, who routinely use hand-operated saws. We undertook a cadaveric study measuring vibration associated with a tibial cut using battery-operated saws. Three surgeons undertook three tibial cuts each on cadaveric tibiae. Measurements were taken using a frequency-weighted root mean square acceleration, with the vibration total value calculated as the root of the sums squared in each of the three axes. A mean (SD) vibration magnitude of 1 (0.2) m/s2 in the X-axis, 10.3 (1.9) m/s2 in the Y-axis and 4.2 (1.3) m/s2 in the Z-axis was observed. The weighted root mean squared magnitude of vibration was 11.3 (1.7) m/s2. These results suggest an EAV of 23 min and ELV of 1 h 33 min using this equipment. Our results demonstrate that use of a battery-operated sagittal saw can transmit levels of hand-arm vibration approaching the EAV or ELV through prolonged use. Further study is necessary to quantify this risk and establish whether surveillance is necessary for orthopaedic surgeons. © The Author 2017. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  19. Hand-arm vibration syndrome among a group of construction workers in Malaysia.

    PubMed

    Su, Ting Anselm; Hoe, Victor Chee Wai; Masilamani, Retneswari; Awang Mahmud, Awang Bulgiba

    2011-01-01

    To determine the extent of hand transmitted vibration exposure problems, particularly hand-arm vibration syndrome (HAVS), among construction workers in Malaysia. A cross-sectional study was conducted on a construction site in Kuala Lumpur, Malaysia. 243 workers were recruited. Questionnaire interviews and hand examinations were administered to 194 respondents. Vibration magnitudes for concrete breakers, drills and grinders were measured using a 3-axis accelerometer. Clinical outcomes were compared and analysed according to vibration exposure status. Vibration total values for concrete breakers, impact drills and grinders were 10.02 ms(-2), 7.72 ms(-2) and 5.29ms(-2), respectively. The mean 8 h time-weighted hand transmitted vibration exposure, A(8), among subjects on current and previous construction sites was 7.52 (SD 2.68) ms(-2) and 9.21 (SD 2.48) ms(-2), respectively. Finger tingling, finger numbness, musculoskeletal problems of the neck, finger coldness, abnormal Phalen's test and abnormal light touch sensation were significantly more common in the high vibration exposure group (n=139) than the low-moderate vibration exposure group (n=54). Mean total lifetime vibration dose among exposed subjects was 15.2 (SD 3.2) m(2) h(3) s(-4) (ln scale). HAVS prevalence was 18% and the prevalence ratio of stage 1 and higher disease in the high vibration exposure group versus the low-moderate vibration exposure group was 4.86 (95% CI 1.19 to 19.80). Hand transmitted vibration is a recognisable problem in tropical countries including Malaysia. The current study has identified clinical symptoms and signs suggesting HAVS among construction workers exposed to hand transmitted vibration in a warm environment.

  20. Do exposure limits for hand-transmitted vibration prevent carpal tunnel syndrome?

    PubMed

    Gillibrand, S; Ntani, G; Coggon, D

    2016-07-01

    An apparently high frequency of carpal tunnel syndrome (CTS) among shipyard workers undergoing health surveillance because of exposure to hand-transmitted vibration (HTV) prompted concerns that current regulatory limits on exposure might not protect adequately against the disorder. To explore whether within regulatory limits, higher exposures to HTV predispose to CTS. As part of a retrospective audit, we compared duration and current intensity of exposure to HTV in cases with new-onset CTS and controls matched for age. Conditional logistic regression was used to quantify associations, which were summarized by odds ratios (ORs) and 95% confidence intervals (CIs). There were 23 cases and 55 controls. After adjustment for body mass index and previous diagnosis of diabetes, no clear associations were observed either with duration of exposure to HTV or with current intensity of exposure. Risk was non-significantly elevated in men with ≥30 years' exposure to HTV (OR 1.6), but in the highest category of current exposure [8-h energy-equivalent frequency-weighted acceleration (A8) ≥ 4.0 m/s(2)], risk was lower than that in the reference category (A8 < 2.5 m/s(2)). Moreover, there was a significantly reduced risk of CTS in men with a previous diagnosis of hand-arm vibration syndrome (HAVS) (OR 0.2, 95% CI 0.1-0.9). We found no evidence that below the current limit for A(8) of 5 m/s(2), higher exposures to HTV predispose to CTS. However, care should be taken not to overlook the possibility of treatable CTS when workers with diagnosed HAVS present with new or worsening sensory symptoms in the hand. © The Author 2016. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Tool-specific performance of vibration-reducing gloves for attenuating palm-transmitted vibrations in three orthogonal directions

    PubMed Central

    Dong, Ren G.; Welcome, Daniel E.; Peterson, Donald R.; Xu, Xueyan S.; McDowell, Thomas W.; Warren, Christopher; Asaki, Takafumi; Kudernatsch, Simon; Brammer, Antony

    2015-01-01

    Vibration-reducing (VR) gloves have been increasingly used to help reduce vibration exposure, but it remains unclear how effective these gloves are. The purpose of this study was to estimate tool-specific performances of VR gloves for reducing the vibrations transmitted to the palm of the hand in three orthogonal directions (3-D) in an attempt to assess glove effectiveness and aid in the appropriate selection of these gloves. Four typical VR gloves were considered in this study, two of which can be classified as anti-vibration (AV) gloves according to the current AV glove test standard. The average transmissibility spectrum of each glove in each direction was synthesized based on spectra measured in this study and other spectra collected from reported studies. More than seventy vibration spectra of various tools or machines were considered in the estimations, which were also measured in this study or collected from reported studies. The glove performance assessments were based on the percent reduction of frequency-weighted acceleration as is required in the current standard for assessing the risk of vibration exposures. The estimated tool-specific vibration reductions of the gloves indicate that the VR gloves could slightly reduce (<5%) or marginally amplify (<10%) the vibrations generated from low-frequency (<25 Hz) tools or those vibrating primarily along the axis of the tool handle. With other tools, the VR gloves could reduce palm-transmitted vibrations in the range of 5%–58%, primarily depending on the specific tool and its vibration spectra in the three directions. The two AV gloves were not more effective than the other gloves with some of the tools considered in this study. The implications of the results are discussed. Relevance to industry Hand-transmitted vibration exposure may cause hand-arm vibration syndrome. Vibration-reducing gloves are considered as an alternative approach to reduce the vibration exposure. This study provides useful information

  2. The apparent mass and mechanical impedance of the hand and the transmission of vibration to the fingers, hand, and arm

    NASA Astrophysics Data System (ADS)

    Concettoni, Enrico; Griffin, Michael

    2009-08-01

    Although hand-transmitted vibration causes injury and disease, most often evident in the fingers, the biodynamic responses of the fingers, hand, and arm are not yet well understood. A method of investigating the motion of the entire finger-hand-arm system, based on the simultaneous measurement of the biodynamic response at the driving point and the transmissibility to many points on the finger-hand-arm system, is illustrated. Fourteen male subjects participated in an experiment in which they pushed down on a vertically vibrating metal plate with their right forearm pronated and their elbow bent at 90°. The apparent mass and mechanical impedance of the finger-hand-arm system were measured for each of seven different contact conditions between the plate and the fingers and hand. Simultaneously, the vibration of the fingers, hand, and arm was measured at 41 locations using a scanning laser Doppler vibrometer. Transmissibilities showed how the vibration was transmitted along the arm and allowed the construction of spectral operating deflection shapes showing the vibration pattern of the fingers, hand, and arm for each of the seven contact conditions. The vibration patterns at critical frequencies for each contact condition have been used to explain features in the driving point biodynamic responses and the vibration behaviour of the hand-arm system. Spectral operating deflection shapes for the upper limb assist the interpretation of driving point biodynamic responses and help to advance understanding required to predict, explain, and control the various effects of hand-transmitted vibration.

  3. Dupuytren's contracture and occupational exposure to hand-transmitted vibration

    PubMed Central

    Palmer, Keith T; D'Angelo, Stefania; Syddall, Holly; Griffin, Michael J; Cooper, Cyrus; Coggon, David

    2014-01-01

    Aims The relation between Dupuytren's contracture and occupational exposure to hand-transmitted vibration (HTV) has frequently been debated. We explored associations in a representative national sample of workers with well-characterised exposure to HTV. Methods We mailed a questionnaire to 21 201 subjects aged 16–64 years, selected at random from the age-sex registers of 34 general practices in Great Britain and to 993 subjects chosen randomly from military pay records, asking about occupational exposure to 39 sources of HTV and about fixed flexion contracture of the little or ring finger. Analysis was restricted to men at work in the previous week. Estimates were made of average daily vibration dose (A(8) root mean squared velocity (rms)) over that week. Associations with Dupuytren's contracture were estimated by Poisson regression, for lifetime exposure to HTV and for exposures in the past week >A(8) of 2.8 ms−2 rms. Estimates of relative risk (prevalence ratio (PR)) were adjusted for age, smoking status, social class and certain manual activities at work. Results In all 4969 eligible male respondents supplied full information on the study variables. These included 72 men with Dupuytren's contracture, 2287 with occupational exposure to HTV and 409 with A(8)>2.8 ms−2 in the past week. PRs for occupational exposure to HTV were elevated 1.5-fold. For men with an A(8)>2.8 ms−2 in the past week, the adjusted PR was 2.85 (95% CI 1.37 to 5.97). Conclusions Our findings suggest that risk of Dupuytren's contracture is more than doubled in men with high levels of weekly exposure to HTV. PMID:24449599

  4. Minimum health and safety requirements for workers exposed to hand-transmitted vibration and whole-body vibration in the European Union; a review

    PubMed Central

    Griffin, M

    2004-01-01

    In 2002, the Parliament and Commission of the European Community agreed "minimum health and safety requirements" for the exposure of workers to the risks arising from vibration. The Directive defines qualitative requirements and also quantitative requirements in the form of "exposure action values" and "exposure limit values". The quantitative guidance is based on, but appears to conflict with, the guidance in International Standards for hand-transmitted vibration (ISO 5349) and whole-body vibration (ISO 2631). There is a large internal inconsistency within the Directive for short duration exposures to whole-body vibration: the two alternative methods give very different values. It would appear prudent to base actions on the qualitative guidance (i.e. reducing risk to a minimum) and only refer to the quantitative guidance where there is no other reasonable basis for the identification of risk (i.e. similar exposures are not a suspected cause of injury). Health surveillance and other precautions will be appropriate wherever there is reason to suspect a risk and will not be restricted to conditions where the exposure action value is exceeded. PMID:15090658

  5. Hand-arm vibration syndrome: a common occupational hazard in industrialized countries.

    PubMed

    Heaver, C; Goonetilleke, K S; Ferguson, H; Shiralkar, S

    2011-06-01

    Regular exposure to hand-transmitted vibration can result in symptoms and signs of peripheral vascular, neurological and other disorders collectively known as the hand-arm vibration syndrome (HAVS). A significant proportion of workers can suffer from HAVS after using vibrating power tools. HAVS is a chronic and progressive disorder. Early recognition and prevention is the key to managing vibrating tool exposures and health effects. This article gives a broad overview of the condition with a detailed account of its pathogenesis, identification and management.

  6. Vibration-reducing gloves: transmissibility at the palm of the hand in three orthogonal directions.

    PubMed

    McDowell, Thomas W; Dong, Ren G; Welcome, Daniel E; Xu, Xueyan S; Warren, Christopher

    2013-01-01

    Vibration-reducing (VR) gloves are commonly used as a means to help control exposures to hand-transmitted vibrations generated by powered hand tools. The objective of this study was to characterise the vibration transmissibility spectra and frequency-weighted vibration transmissibility of VR gloves at the palm of the hand in three orthogonal directions. Seven adult males participated in the evaluation of seven glove models using a three-dimensional hand-arm vibration test system. Three levels of hand coupling force were applied in the experiment. This study found that, in general, VR gloves are most effective at reducing vibrations transmitted to the palm along the forearm direction. Gloves that are found to be superior at reducing vibrations in the forearm direction may not be more effective in the other directions when compared with other VR gloves. This casts doubts on the validity of the standardised glove screening test. Practitioner Summary: This study used human subjects to measure three-dimensional vibration transmissibility of vibration-reducing gloves at the palm and identified their vibration attenuation characteristics. This study found the gloves to be most effective at reducing vibrations along the forearm direction. These gloves did not effectively attenuate vibration along the handle axial direction.

  7. Vibration-reducing gloves: transmissibility at the palm of the hand in three orthogonal directions

    PubMed Central

    McDowell, Thomas W.; Dong, Ren G.; Welcome, Daniel E.; Xu, Xueyan S.; Warren, Christopher

    2015-01-01

    Vibration-reducing (VR) gloves are commonly used as a means to help control exposures to hand-transmitted vibrations generated by powered hand tools. The objective of this study was to characterise the vibration transmissibility spectra and frequency-weighted vibration transmissibility of VR gloves at the palm of the hand in three orthogonal directions. Seven adult males participated in the evaluation of seven glove models using a three-dimensional hand–arm vibration test system. Three levels of hand coupling force were applied in the experiment. This study found that, in general, VR gloves are most effective at reducing vibrations transmitted to the palm along the forearm direction. Gloves that are found to be superior at reducing vibrations in the forearm direction may not be more effective in the other directions when compared with other VR gloves. This casts doubts on the validity of the standardised glove screening test. Practitioner Summary This study used human subjects to measure three-dimensional vibration transmissibility of vibration-reducing gloves at the palm and identified their vibration attenuation characteristics. This study found the gloves to be most effective at reducing vibrations along the forearm direction. These gloves did not effectively attenuate vibration along the handle axial direction. PMID:24160755

  8. [The hand-arm vibration syndrome: (II). The diagnostic aspects and fitness criteria].

    PubMed

    Bovenzi, M

    1999-01-01

    Part II of this paper reviews the clinical and laboratory methods to diagnose the neurological, vascular and osteoarticular components of the hand-arm vibration syndrome. The prognosis and reversibility of vibration-induced neurological and vascular disorders after cessation of vibration exposure or the introduction of powered tools equipped with vibration isolation systems are discussed on the basis of the results of follow-up clinical investigations and longitudinal epidemiologic studies. Finally, the review debates some of the methodological aspects connected with the health surveillance of vibration-exposed workers and considers the possible medical contra-indications for prolonged exposure to hand-transmitted vibration.

  9. The relationships between hand coupling force and vibration biodynamic responses of the hand-arm system.

    PubMed

    Pan, Daniel; Xu, Xueyan S; Welcome, Daniel E; McDowell, Thomas W; Warren, Christopher; Wu, John; Dong, Ren G

    2018-06-01

    This study conducted two series of experiments to investigate the relationships between hand coupling force and biodynamic responses of the hand-arm system. In the first experiment, the vibration transmissibility on the system was measured as a continuous function of grip force while the hand was subjected to discrete sinusoidal excitations. In the second experiment, the biodynamic responses of the system subjected to a broadband random vibration were measured under five levels of grip forces and a combination of grip and push forces. This study found that the transmissibility at each given frequency increased with the increase in the grip force before reaching a maximum level. The transmissibility then tended to plateau or decrease when the grip force was further increased. This threshold force increased with an increase in the vibration frequency. These relationships remained the same for both types of vibrations. The implications of the experimental results are discussed. Practitioner Summary: Shocks and vibrations transmitted to the hand-arm system may cause injuries and disorders of the system. How to take hand coupling force into account in the risk assessment of vibration exposure remains an important issue for further studies. This study is designed and conducted to help resolve this issue.

  10. Evaluation of protective gloves and working techniques for reducing hand-arm vibration exposure in the workplace.

    PubMed

    Milosevic, Matija; McConville, Kristiina M Valter

    2012-01-01

    Operation of handheld power tools results in exposure to hand-arm vibrations, which over time lead to numerous health complications. The objective of this study was to evaluate protective equipment and working techniques for the reduction of vibration exposure. Vibration transmissions were recorded during different work techniques: with one- and two-handed grip, while wearing protective gloves (standard, air and anti-vibration gloves) and while holding a foam-covered tool handle. The effect was examined by analyzing the reduction of transmitted vibrations at the wrist. The vibration transmission was recorded with a portable device using a triaxial accelerometer. The results suggest large and significant reductions of vibration with appropriate safety equipment. Reductions of 85.6% were achieved when anti-vibration gloves were used. Our results indicated that transmitted vibrations were affected by several factors and could be measured and significantly reduced.

  11. [Hand-arm vibration syndrome in a nurse carrying out gypsum cutting operations].

    PubMed

    Speziale, Martina; Picchiotti, E

    2009-01-01

    A professional nurse, employed mainly on gypsum cutting operations, developed a hand-arm vibration syndrome with Raynaud's phenomenon, neurosensitive disorders and impairment of the bone and joints apparatus of the hand and arm. The nurse underwent diagnostic investigations (cold test, X-ray of the upper limbs, blood tests); also the vibration levels transmitted from instrument were measured and the exposure times were established. Clinical investigations showed the presence of a hand-arm vibration syndrome with secondary Raynaud's phenomenon and environmental surveys revealed very high vibration levels, such as could be associated with the disease with a causal relationship. In the literature no reports exist of the vibration syndrome being associated with health care workers in orthopaedic departments. The case described in this study occurred because of peculiar organisational factors that most likely have never occurred in other hospitals or orthopaedic departments.

  12. Hand-arm vibration disorder among grass-cutter workers in Malaysia.

    PubMed

    Azmir, Nor Azali; Ghazali, Mohd Imran; Yahya, Musli Nizam; Ali, Mohamad Hanafi

    2016-09-01

    Prolonged exposure to hand-transmitted vibration from grass-cutting machines has been associated with increasing occurrences of symptoms and signs of occupational diseases related to hand-arm vibration syndrome (HAVS). A cross-sectional study was carried out using an adopted HAVS questionnaire on hand-arm vibration exposure and symptoms distributed to 168 male workers from the grass and turf maintenance industry who use hand-held grass-cutting machines as part of their work. The prevalence ratio and symptom correlation to HAVS between high and low-moderate exposure risk groups were evaluated. There were positive HAVS symptoms relationships between the low-moderate exposure group and the high exposure group among hand-held grass-cutting workers. The prevalence ratio was considered high because there were indicators that fingers turned white and felt numb, 3.63, 95% CI [1.41, 9.39] and 4.24, 95% CI [2.18, 8.27], respectively. Less than 14.3% of workers stated that they were aware of the occupational hand-arm vibration, and it seemed to be related to the finger blanching and numbness. The results suggest that HAVS is under-diagnosed in Malaysia, especially in the agricultural sectors. More information related to safety and health awareness programmes for HAVS exposure is required among hand-held grass-cutting workers.

  13. An examination of the vibration transmissibility of the hand-arm system in three orthogonal directions.

    PubMed

    Welcome, Daniel E; Dong, Ren G; Xu, Xueyan S; Warren, Christopher; McDowell, Thomas W; Wu, John Z

    2015-02-01

    The objective of this study is to enhance the understanding of the vibration transmission in the hand-arm system in three orthogonal directions ( X, Y , and Z ). For the first time, the transmitted vibrations distributed on the entire hand-arm system exposed in the three orthogonal directions via a 3-D vibration test system were measured using a 3-D laser vibrometer. Seven adult male subjects participated in the experiment. This study confirms that the vibration transmissibility generally decreased with the increase in distance from the hand and it varied with the vibration direction. Specifically, to the upper arm and shoulder, only moderate vibration transmission was measured in the test frequency range (16 to 500 Hz), and virtually no transmission was measured in the frequency range higher than 50 Hz. The resonance vibration on the forearm was primarily in the range of 16-30 Hz with the peak amplitude of approximately 1.5 times of the input vibration amplitude. The major resonance on the dorsal surfaces of the hand and wrist occurred at around 30-40 Hz and, in the Y direction, with peak amplitude of more than 2.5 times of the input amplitude. At higher than 50 Hz, vibration transmission was effectively limited to the hand and fingers. A major finger resonance was observed at around 100 Hz in the X and Y directions and around 200 Hz in the Z direction. In the fingers, the resonance magnitude in the Z direction was generally the lowest, and the resonance magnitude in the Y direction was generally the highest with the resonance amplitude of 3 times the input vibration, which was similar to the transmissibility at the wrist and hand dorsum. The implications of the results are discussed. Prolonged, intensive exposure to hand-transmitted vibration could result in hand-arm vibration syndrome. While the syndrome's precise mechanisms remain unclear, the characterization of the vibration transmissibility of the system in the three orthogonal dimensions performed in this

  14. An examination of the vibration transmissibility of the hand-arm system in three orthogonal directions

    PubMed Central

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.; Wu, John Z.

    2015-01-01

    The objective of this study is to enhance the understanding of the vibration transmission in the hand-arm system in three orthogonal directions (X, Y, and Z). For the first time, the transmitted vibrations distributed on the entire hand-arm system exposed in the three orthogonal directions via a 3-D vibration test system were measured using a 3-D laser vibrometer. Seven adult male subjects participated in the experiment. This study confirms that the vibration transmissibility generally decreased with the increase in distance from the hand and it varied with the vibration direction. Specifically, to the upper arm and shoulder, only moderate vibration transmission was measured in the test frequency range (16 to 500 Hz), and virtually no transmission was measured in the frequency range higher than 50 Hz. The resonance vibration on the forearm was primarily in the range of 16–30 Hz with the peak amplitude of approximately 1.5 times of the input vibration amplitude. The major resonance on the dorsal surfaces of the hand and wrist occurred at around 30–40 Hz and, in the Y direction, with peak amplitude of more than 2.5 times of the input amplitude. At higher than 50 Hz, vibration transmission was effectively limited to the hand and fingers. A major finger resonance was observed at around 100 Hz in the X and Y directions and around 200 Hz in the Z direction. In the fingers, the resonance magnitude in the Z direction was generally the lowest, and the resonance magnitude in the Y direction was generally the highest with the resonance amplitude of 3 times the input vibration, which was similar to the transmissibility at the wrist and hand dorsum. The implications of the results are discussed. Relevance to industry Prolonged, intensive exposure to hand-transmitted vibration could result in hand-arm vibration syndrome. While the syndrome's precise mechanisms remain unclear, the characterization of the vibration transmissibility of the system in the three orthogonal

  15. Spatial patterns of cutaneous vibration during whole-hand haptic interactions

    PubMed Central

    Hayward, Vincent; Visell, Yon

    2016-01-01

    We investigated the propagation patterns of cutaneous vibration in the hand during interactions with touched objects. Prior research has highlighted the importance of vibrotactile signals during haptic interactions, but little is known of how vibrations propagate throughout the hand. Furthermore, the extent to which the patterns of vibrations reflect the nature of the objects that are touched, and how they are touched, is unknown. Using an apparatus comprised of an array of accelerometers, we mapped and analyzed spatial distributions of vibrations propagating in the skin of the dorsal region of the hand during active touch, grasping, and manipulation tasks. We found these spatial patterns of vibration to vary systematically with touch interactions and determined that it is possible to use these data to decode the modes of interaction with touched objects. The observed vibration patterns evolved rapidly in time, peaking in intensity within a few milliseconds, fading within 20–30 ms, and yielding interaction-dependent distributions of energy in frequency bands that span the range of vibrotactile sensitivity. These results are consistent with findings in perception research that indicate that vibrotactile information distributed throughout the hand can transmit information regarding explored and manipulated objects. The results may further clarify the role of distributed sensory resources in the perceptual recovery of object attributes during active touch, may guide the development of approaches to robotic sensing, and could have implications for the rehabilitation of the upper extremity. PMID:27035957

  16. The effects of vibration-reducing gloves on finger vibration

    PubMed Central

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.

    2015-01-01

    Vibration-reducing (VR) gloves have been used to reduce the hand-transmitted vibration exposures from machines and powered hand tools but their effectiveness remains unclear, especially for finger protection. The objectives of this study are to determine whether VR gloves can attenuate the vibration transmitted to the fingers and to enhance the understanding of the mechanisms of how these gloves work. Seven adult male subjects participated in the experiment. The fixed factors evaluated include hand force (four levels), glove condition (gel-filled, air bladder, no gloves), and location of the finger vibration measurement. A 3-D laser vibrometer was used to measure the vibrations on the fingers with and without wearing a glove on a 3-D hand-arm vibration test system. This study finds that the effect of VR gloves on the finger vibration depends on not only the gloves but also their influence on the distribution of the finger contact stiffness and the grip effort. As a result, the gloves increase the vibration in the fingertip area but marginally reduce the vibration in the proximal area at some frequencies below 100 Hz. On average, the gloves reduce the vibration of the entire fingers by less than 3% at frequencies below 80 Hz but increase at frequencies from 80 to 400 Hz. At higher frequencies, the gel-filled glove is more effective at reducing the finger vibration than the air bladder-filled glove. The implications of these findings are discussed. Relevance to industry Prolonged, intensive exposure to hand-transmitted vibration can cause hand-arm vibration syndrome. Vibration-reducing gloves have been used as an alternative approach to reduce the vibration exposure. However, their effectiveness for reducing finger-transmitted vibrations remains unclear. This study enhanced the understanding of the glove effects on finger vibration and provided useful information on the effectiveness of typical VR gloves at reducing the vibration transmitted to the fingers. The new

  17. National regulations for diagnostics in health surveillance, therapy and compensation of hand-transmitted vibration injury in Japan.

    PubMed

    Yamada, Shin'ya

    2002-01-01

    During the period of technological innovation and rapid economic development, portable power tools were introduced on a large scale in Japan. Vibration disease from the operation of those tools and its prevention and therapy became urgent social problems in the 1970s. This paper aims to introduce national regulations in Japan for diagnostics in the health surveillance, certification, therapy and compensation of vibration disease and evaluates them in the present perspective. Relevant laws, regulations and administrative directives were described in chronological order. Effect of those laws, regulations and directives were evaluated by statistics. Relevant regulations were established in 1947 and were revised in the 1960s and 1970s. According to those regulations, administrative directives were issued. Relevant vibration-disease statistics improved from the 1970s to 1990s. The annual ratio of workers examined was 95% to 100% in national forests (NFs), 47.3% in 1980 and 40.8% in 1990 in private industry (PI). The number of workers certified in NFs was 1,796 from 1971-1975, with a decrease to nine from 1991-1995, while in PI there were 9,783 from 1976-1980, decreasing to 2,331 from 1991-1995. However, in the construction industry the number increased again in the 1990s. The top four workers certified by the type of tool from 1994-1997 were operators of rock drills, chainsaws, pick hammers and concrete vibrators. The annual number of workers under treatment (at highest level) was 3,605 (1982; NFs) and 13,501 (1987; PI), with a decrease to 3,481 (1997; NFs) and 8,958 (1997; PI). Regulations for compensation covered 3,670 workers from 1965 to 1997 (NFs) and 22,723 from 1976 to 1997 (PI) in medical treatment benefits, and 189 (NFs) and 15,448 (PI) in disability benefits during the same term. The national regulations developed in Japan since 1965 for health surveillance, certification, therapy and compensation of hand-transmitted vibration disease have proven effective for

  18. Vascular hand-arm vibration syndrome--magnetic resonance angiography.

    PubMed

    Poole, C J M; Cleveland, T J

    2016-01-01

    The diagnosis of vascular hand-arm vibration syndrome (HAVS) requires consistent symptoms, photographic evidence of digital blanching and sufficient exposure to hand-transmitted vibration (HTV; A(8) > 2.5 m/s2). There is no reliable quantitative investigation for distinguishing HAVS from other causes of Raynaud's phenomenon and from normal individuals. Hypothenar and thenar hammer syndromes produce similar symptoms to HAVS but are difficult to diagnose clinically and may be confused with HAVS. Magnetic resonance angiography (MRA) is a safe and minimally invasive method of visualizing blood vessels. Three cases of vascular HAVS are described in which MRA revealed occlusions of the ulnar, radial and superficial palmar arteries. It is proposed that HTV was the cause of these occlusions, rather than blows to the hand unrelated to vibration, the assumed mechanism for the hammer syndromes. All three cases were advised not to expose their hands to HTV despite one of them being at Stockholm vascular stage 2 (early). MRA should be the investigation of choice for stage 2 vascular HAVS or vascular HAVS with unusual features or for a suspected hammer syndrome. The technique is however technically challenging and best done in specialist centres in collaboration with an occupational physician familiar with the examination of HAVS cases. Staging for HAVS should be developed to include anatomical arterial abnormalities as well as symptoms and signs of blanching. Workers with only one artery supplying a hand, or with only one palmar arch, may be at increased risk of progression and therefore should not be exposed to HTV irrespective of their Stockholm stage. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Effect of skin-transmitted vibration enhancement on vibrotactile perception.

    PubMed

    Tanaka, Yoshihiro; Ueda, Yuichiro; Sano, Akihito

    2015-06-01

    Vibration on skin elicited by the mechanical interaction of touch between the skin and an object propagates to skin far from the point of contact. This paper investigates the effect of skin-transmitted vibration on vibrotactile perception. To enhance the transmission of high-frequency vibration on the skin, stiff tape was attached to the skin so that the tape covered the bottom surface of the index finger from the periphery of the distal interphalangeal joint to the metacarpophalangeal joint. Two psychophysical experiments with high-frequency vibrotactile stimuli of 250 Hz were conducted. In the psychophysical experiments, discrimination and detection thresholds were estimated and compared between conditions of the presence or the absence of the tape (normal bare finger). A method of limits was applied for the detection threshold estimation, and the discrimination task using a reference stimulus and six test stimuli with different amplitudes was applied for the discrimination threshold estimation. The stimulation was given to bare fingertips of participants. Result showed that the detection threshold was enhanced by attaching the tape, and the discrimination threshold enhancement by attaching the tape was confirmed for participants who have relatively large discrimination threshold under normal bare finger. Then, skin-transmitted vibration was measured with an accelerometer with the psychophysical experiments. Result showed that the skin-transmitted vibration when the tape was attached to the skin was larger than that when normal bare skin. There is a correlation between the increase in skin-transmitted vibration and the enhancement of the discrimination threshold.

  20. Hand function in workers with hand-arm vibration syndrome.

    PubMed

    Cederlund, R; Isacsson, A; Lundborg, G

    1999-01-01

    Hand-arm vibration syndrome has been specially addressed in the Scandinavian countries in recent years, but the syndrome is still not sufficiently recognized in many countries. The object of this preliminary study was to describe the nature and character of vibration-induced impairment in the hands of exposed workers. Twenty symptomatic male workers (aged 28 to 65 years) subjected to vibration by hand-held tools were interviewed about subjective symptoms and activities of daily living and were assessed with a battery of objective tests for sensibility, dexterity, grip function, and grip strength. The test results were compared with normative data. The majority of patients complained of cold intolerance, numbness, pain, sensory impairment, and difficulties in handling manual tools and in handwriting. The various objective tests showed considerable variation in indications of pathologic outcome, revealing differences in sensitivity to detect impaired hand function. Semmes-Weinstein monofilament testing for perception of light touch-deep pressure sensation, the small-object shape identification test, and moving two-point discrimination testing for functional sensibility provided the most indications of pathologic outcomes. The authors conclude that vibration-exposed patients present considerable impairment in hand function.

  1. Frequency weighting derived from power absorption of fingers-hand-arm system under z(h)-axis vibration.

    PubMed

    Dong, Ren G; Welcome, Daniel E; McDowell, Thomas W; Wu, John Z; Schopper, Aaron W

    2006-01-01

    The objectives of this study are to derive the frequency weighting from three vibration power absorption (VPA) methods (finger VPA, palm VPA, and total or hand VPA), and to explore whether these energy methods are better than the currently accepted acceleration method. To calculate the VPA weightings, the mechanical impedance of eight subjects exposed to a broadband random vibration spectrum in the z(h)-axis using 18 combinations of hand couplings and applied forces was measured. The VPA weightings were compared with the frequency weighting specified in ISO 5349-1 [2001. Mechanical Vibration--Measurement and Evaluation of Human Exposure to Hand--Transmitted Vibration--Part 1: General Requirements. International Organization for Standardization, Geneva, Switzerland]. This study found that the hand and palm VPA weightings are very similar to the ISO weighting but the finger VPA weighting for the combined grip and push action is much higher than the ISO weighting at frequencies higher than 25 Hz. Therefore, this study predicted that the total power absorption of the entire hand-arm system is likely to be correlated with psychophysical response or subjective sensation. However, if the ISO weighting method cannot yield good predictions of the vibration-induced disorders in the fingers and hand, the hand and palm energy methods are unlikely to yield significantly better predictions. The finger VPA is a vibration measure between unweighted and ISO weighted accelerations. The palm VPA method may have some value for studying the disorders in the wrist-arm system.

  2. A method to quantify hand-transmitted vibration exposure based on the biodynamic stress concept.

    PubMed

    Dong, R G; Welcome, D E; Wu, J Z

    2007-11-01

    This study generally hypothesized that the vibration-induced biodynamic stress and number of its cycles in a substructure of the hand-arm system play an important role in the development of vibration-induced disorders in the substructure. As the first step to test this hypothesis, the specific aims of this study were to develop a practical method to quantify the biodynamic stress-cycle measure, to compare it with ISO-weighted and unweighted accelerations, and to assess its potential for applications. A mechanical-equivalent model of the system was established using reported experimental data. The model was used to estimate the average stresses in the fingers and palm. The frequency weightings of the stresses in these substructures were derived using the proposed stress-cycle measure. This study found the frequency dependence of the average stress distributed in the fingers is different from that in the palm. Therefore, this study predicted that the frequency dependencies of finger disorders could also be different from those of the disorders in the palm, wrist, and arms. If vibration-induced white finger (VWF) is correlated better with unweighted acceleration than with ISO-weighted acceleration, the biodynamic stress distributed in the fingers is likely to play a more important role in the development of VWF than is th e biodynamic stressdistributed in the other substructures of the hand-arm system. The results of this study also suggest that the ISO weighting underestimates the high-frequency effect on the finger disorder development but it may provide a reasonable risk assessment of the disorders in the wrist and arm.

  3. Assessing the influence of antivibration glove on digital vascular responses to acute hand-arm vibration.

    PubMed

    Mahbub, Md H; Yokoyama, Kenjiro; Laskar, Md S; Inoue, Masaiwa; Takahashi, Yukio; Yamamoto, Shinji; Harada, Noriaki

    2007-05-01

    This study was designed to assess the influence of an antivibration glove on digital vascular responses in healthy subjects exposed to short-term grasping of a vibrating handle. To measure finger blood flow (FBF) and finger skin temperature (FST) once at the end of every min, a blood flowmeter sensor was attached to the dorsum and a thermistor sensor was attached to the medial surface of the subject's middle phalanx of the third finger of the right hand. After 5 min of baseline measurements without or with an antivibration glove meeting ISO standard 10819, worn on the right hand, subjects gripped a vibrating handle with the same hand for a period of 5 min. Vibration was generated at two frequencies of 31.5 Hz and 250 Hz with a frequency weighted rms acceleration of 5.5 m/s(2). FBF and FST continued to be recorded for a further 5 min after release of the vibrating handle. Statistical analysis showed no significant change after vibration exposure in either FST or FBF at 250 Hz, compared to baseline (control) measurements while using the antivibration glove. At 31.5 Hz, FBF data exhibited a significant difference between before and after grasping of vibrating handle, which was less under the condition of wearing the antivibration glove than under the condition of bare hand. The results provide evidence that the antivibration glove considerably influenced finger vascular changes in healthy subjects induced by vibration exposure, especially against high frequency vibration. Further studies are required to assess finger vascular responses to hand-transmitted vibration with antivibration gloves of different manufacturers.

  4. Reliability of a Malay-translated questionnaire for use in a hand-arm vibration syndrome study in Malaysia.

    PubMed

    Su, T A; Hoe, V C W

    2008-12-01

    Validity and reliability of the information relating to hand-transmitted vibration exposure and vibration-related health outcome are very important for case finding in hand-arm vibration syndrome (HAVS) studies. In a local HAVS study among a group of construction workers in Kuala Lumpur, Malaysia, a questionnaire translated into Malay was created based on the Hand-transmitted Vibration Health Surveillance--Initial Questionnaire and Clinical Assessment, from Vibration Injury Network. This study was conducted to determine the reliability of standardised questions in the questionnaire used in the study. 15 subjects were selected randomly from the sampling frame of the HAVS study. Test-retest reliability was conducted on all items contained in parts 1-6 of the questionnaire and clinical assessment form, with an interval of 13-14 days between the first and second administration. Kappa coefficient and percentage agreement were calculated for all standardised questions. The kappa coefficient and percentage agreement for all standardised questions varied from -0.174 to 1.000 and 66.7 to 100.0 percent, respectively. The kappa coefficient for important questions related to current vibratory tool usage, tingling, numbness and hand grip weakness were 0.714, 0.432, -0.077 and -0.120, respectively, while the percentage agreement for current vibratory tool usage, finger colour change, tingling, numbness and hand grip weakness were 85.7 percent, 92.8 percent, 79.5 percent, 85.7 percent and 71.4 percent, respectively. Intra-rater reliability on the extent of vibration exposure was good, with the intra-class correlation coefficient (95 percent confidence interval) ranging from 0.786 (0.334-0.931) to 0.975 (0.923-0.992). Critical questions on vascular, neurological and musculoskeletal symptoms of HAVS were found to be reliable. The history on the extent of vibration exposure revealed good reliability when explored by the investigator alone. This questionnaire is considered reliable

  5. Reduction of vibration forces transmitted from a radiator cooling fan to a vehicle body

    NASA Astrophysics Data System (ADS)

    Lim, Jonghyuk; Sim, Woojeong; Yun, Seen; Lee, Dongkon; Chung, Jintai

    2018-04-01

    This article presents methods for reducing transmitted vibration forces caused by mass unbalance of the radiator cooling fan during vehicle idling. To identify the effects of mass unbalance upon the vibration characteristics, vibration signals of the fan blades were experimentally measured both with and without an added mass. For analyzing the vibration forces transmitted to the vehicle body, a dynamic simulation model was established that reflected the vibration characteristics of the actual system. This process included a method described herein for calculating the equivalent stiffness and the equivalent damping of the shroud stators and rubber mountings. The dynamic simulation model was verified by comparing its results with experimental results of the radiator cooling fan. The dynamic simulation model was used to analyze the transmitted vibration forces at the rubber mountings. Also, a measure was established to evaluate the effects of varying the design parameters upon the transmitted vibration forces. We present design guidelines based on these analyses to reduce the transmitted vibration forces of the radiator cooling fan.

  6. Subjective scaling of hand-arm vibration.

    PubMed

    Maeda, Setsuo; Shibata, Nobuyuki

    2008-04-01

    The purpose of this research was to establish a scale for comfort with regard to hand-arm vibration using the category judgment method and to validate the frequency-weighting method of the ISO 5349-1 standard. Experiments were conducted using random signals as stimuli. These stimuli consisted of three types of signal, namely designated stimulus F, with flat power spectrum density (PSD) ranging from 1 to 1,000 Hz, stimulus H with PSD which became 20 dB higher at 1,000 Hz than at 1 Hz, and stimulus L that had a PSD 20 dB lower at 1,000 Hz. These stimuli were selected from the specific spectrum patterns of hand-held vibration tools. These signals were modified by the Wh frequency weighting in accordance with ISO 5349-1, and the R.M.S. values were adjusted to be equal. In addition, the signal levels were varied over a range of five steps to create 15 kinds of individual stimuli. The subjects sat in front of a vibrator and grasped the mounted handle which exposed them to vertical vibrations after which they were asked to choose a numerical category to best indicate their perceived level of comfort (or otherwise) during each stimulus. From the experimental results of the category judgment method, the relationship between the psychological values and the frequency-weighted R.M.S. acceleration according to the ISO 5349-1 standard was obtained. It was found that the subjective response scaling of hand-arm vibration can be used for design-objective values of hand-held tool vibration.

  7. An improved biomechanical model for simulating the strain of the hand-arm system under vibration stress.

    PubMed

    Fritz, M

    1991-01-01

    In order to define relationships between the vibration stress and the strain of the human hand-arm system a biomechanical model was developed. The four masses of the model representing the hand, the forearm and the upper arm were connected by dampers and springs in two perpendicular directions. Simulating muscle activity, damped torsion springs were included additionally. The motions of the model were described by a differential matrix equation which was solved by using a 'transfer matrix routine' as well as by numerical integration. Thus, functions with harmonic or transient time courses could be selected as an excitation. The simulated vibrations were compared with those of other hand-arm models. The forces and torques transmitted between the masses, and the energy dissipated by the dampers were computed for several combinations of exciter frequencies and accelerations. The dependence of torques upon excitation agreed fairly well with the behaviour of the arm muscles under vibration as described by various investigators. At frequencies above 100 Hz the energy was dissipated mainly by the dampers between the masses near to the exciter. Transferring this result to the hand-arm system it shows that at high frequencies energy is dissipated by the hand and its palmar tissues and this might be one cause for the incidence of vibration-induced white finger disease.

  8. An examination of an adapter method for measuring the vibration transmitted to the human arms.

    PubMed

    Xu, Xueyan S; Dong, Ren G; Welcome, Daniel E; Warren, Christopher; McDowell, Thomas W

    2015-09-01

    The objective of this study is to evaluate an adapter method for measuring the vibration on the human arms. Four instrumented adapters with different weights were used to measure the vibration transmitted to the wrist, forearm, and upper arm of each subject. Each adapter was attached at each location on the subjects using an elastic cloth wrap. Two laser vibrometers were also used to measure the transmitted vibration at each location to evaluate the validity of the adapter method. The apparent mass at the palm of the hand along the forearm direction was also measured to enhance the evaluation. This study found that the adapter and laser-measured transmissibility spectra were comparable with some systematic differences. While increasing the adapter mass reduced the resonant frequency at the measurement location, increasing the tightness of the adapter attachment increased the resonant frequency. However, the use of lightweight (≤15 g) adapters under medium attachment tightness did not change the basic trends of the transmissibility spectrum. The resonant features observed in the transmissibility spectra were also correlated with those observed in the apparent mass spectra. Because the local coordinate systems of the adapters may be significantly misaligned relative to the global coordinates of the vibration test systems, large errors were observed for the adapter-measured transmissibility in some individual orthogonal directions. This study, however, also demonstrated that the misalignment issue can be resolved by either using the total vibration transmissibility or by measuring the misalignment angles to correct the errors. Therefore, the adapter method is acceptable for understanding the basic characteristics of the vibration transmission in the human arms, and the adapter-measured data are acceptable for approximately modeling the system.

  9. A case report of vibration-induced hand comorbidities in a postwoman

    PubMed Central

    2011-01-01

    Background Prolonged exposure to hand-transmitted vibration is associated with an increased occurrence of symptoms and signs of disorders in the vascular, neurological and osteoarticular systems of the upper limbs. However, the available epidemiological evidence is derived from studies on high vibration levels caused by vibratory tools, whereas little is known about possible upper limb disorders caused by chronic exposure to low vibration levels emitted by fixed sources. Case presentation We present the case of a postwoman who delivered mail for 15 years using a low-powered motorcycle. The woman was in good health until 2002, when she was diagnosed with bilateral Raynaud's phenomenon. In March 2003 a bilateral carpal tunnel syndrome was electromyographically diagnosed; surgical treatment was ineffective. Further examinations in 2005 highlighted the presence of chronic tendonitis (right middle finger flexor). Risk assessment From 1987, for 15 years, our patient rode her motorcycle for 4 h/day, carrying a load of 20-30 kg. For about a quarter of the time she drove over country roads. Using the information collected about the tasks carried out every day by the postwoman and some measurements performed on both handles of the motorcycle, as well as on both iron parts of the handlebars, we reconstructed the woman's previous exposure to hand-arm vibration. 8-hour energy-equivalent frequency weighted acceleration was about 2.4 m/s2. The lifetime dose was 1.5 × 109(m2/s4)hd. Conclusions The particular set of comorbidities presented by our patient suggests a common pathophysiological basis for all the diseases. Considering the level of exposure to vibrations and the lack of specific knowledge on the effects of vibration in women, we hypothesize an association between the work exposure and the onset of the diseases. PMID:21320318

  10. Fingers' vibration transmission and grip strength preservation performance of vibration reducing gloves.

    PubMed

    Hamouda, K; Rakheja, S; Dewangan, K N; Marcotte, P

    2018-01-01

    The vibration isolation performances of vibration reducing (VR) gloves are invariably assessed in terms of power tools' handle vibration transmission to the palm of the hand using the method described in ISO 10819 (2013), while the nature of vibration transmitted to the fingers is ignored. Moreover, the VR gloves with relatively low stiffness viscoelastic materials affect the grip strength in an adverse manner. This study is aimed at performance assessments of 12 different VR gloves on the basis of handle vibration transmission to the palm and the fingers of the gloved hand, together with reduction in the grip strength. The gloves included 3 different air bladder, 3 gel, 3 hybrid, and 2 gel-foam gloves in addition to a leather glove. Two Velcro finger adapters, each instrumented with a three-axis accelerometer, were used to measure vibration responses of the index and middle fingers near the mid-phalanges. Vibration transmitted to the palm was measured using the standardized palm adapter. The vibration transmissibility responses of the VR gloves were measured in the laboratory using the instrumented cylindrical handle, also described in the standard, mounted on a vibration exciter. A total of 12 healthy male subjects participated in the study. The instrumented handle was also used to measure grip strength of the subjects with and without the VR gloves. The results of the study showed that the VR gloves, with only a few exceptions, attenuate handle vibration transmitted to the fingers only in the 10-200 Hz and amplify middle finger vibration at frequencies exceeding 200 Hz. Many of the gloves, however, provided considerable reduction in vibration transmitted to the palm, especially at higher frequencies. These suggest that the characteristics of vibration transmitted to fingers differ considerably from those at the palm. Four of the test gloves satisfied the screening criteria of the ISO 10819 (2013) based on the palm vibration alone, even though these caused

  11. Occupational hand-arm vibration syndrome in Korea.

    PubMed

    Yoo, Cheolin; Lee, Ji-Ho; Lee, Choong-Ryeol; Kim, Yangho; Lee, Hun; Choi, Younghee; Kim, Young Wook; Chae, Chang Ho; Kim, Hyokyoung; Koh, Sang Baek; Kim, Euna; Lee, Lu Jin; Lee, Kiyoung

    2005-06-01

    It is suspected that there is a large number of patients suffering from hand-arm vibration syndrome (HAVS) in Korea. However, no cases have been reported since 1992. This study was conducted to identify HAVS cases and determine the characteristics of the syndrome. In April 2001, the Busan, Ulsan, and Gyeong-Nam Province Occupational Disease Surveillance System (BUGODSS) was established to identify work-related HAVS and other occupational diseases. In the 2 years of this project, occupational physicians from five hospitals in these provinces collected information by way of interviews and questionnaires during mandatory occupational medical examinations. Among the initial 189 suspected HAVS cases, 58 volunteers were given cold-water provocation tests in order to diagnose the vascular component of the disorder. One hundred fifty-four approximately occupational HAVS cases were identified from ca. 21,000 workers. One hundred fifty about of these cases were male. The cases were most often found in workers from the shipbuilding industry, and the grinder was the most common source of vibration exposure. Cases of sensorineural disorder (SD) were more common than cases of vascular disorder (VD). The mean values of the finger skin temperature and its recovery rate at 5 min and 10 min after cold-water provocation were significantly lower in the group with the VD than in the group with the SD. We identified 154 occupational HAVS cases, although no cases have been reported during the occupational medical examinations mandated by the state. The majority of the cases were in workers that used grinders in the shipbuilding industry. We determined that peripheral VD and peripheral SD can progress independently of each other. We conclude that exposure to hand-transmitted vibration (HTV) and HAVS cases are common in shipbuilding industry in Korea. The recovery rate of finger skin temperature after cold-water provocation is one of the useful methods for diagnosing the vascular component

  12. Hand-arm Vibration Effects on Performance, Tactile Acuity, and Temperature of Hand

    PubMed Central

    Forouharmajd, Farhad; Yadegari, Mehrdad; Ahmadvand, Masoumeh; Forouharmajd, Farshad; Pourabdian, Siamak

    2017-01-01

    Effects of vibration appear as mechanical and psychological disorders, including stress reactions, cognitive and movement disorders, problem in concentration and paying attention to the assigned duties. The common signs and symptoms of hand-arm vibration (HAV) in the fingers and hands may appear as pins and needles feeling, tingling, numbness, and also the loss of finger sensation and dexterity. Laboratory Virtual Instrument Engineering Workbench programming software designed for occupational vibrations measurement was used to calculate HAV acceleration. Hole steadiness test is designed to measure involuntary movement of people. V-Pieron test is designed for one of the other aspects of the psycho motor phenomena of steadiness by moving the stylus across a V-form ruler. The two points test was an experiment of touch acuity, which used a caliper by placing the two styli very close on the pad of finger knuckles. The temperature of finger skin is also measured simultaneous to the above tests. Wilcoxon test indicated that a significant decrement in hand steadiness occurred after gripping a vibrating handle for 2 min (P ≤ 0.003). Wilcoxon test also represented a significant change in errors after gripping a grinder vibratory handle (P ≤ 0.003). The differences at all of the knuckles were significant with a confidence interval percentage of 99%. There was a significant reduction in finger skin temperature before and after exposure to vibration (mean = 0.45°C, based on paired sample test). The obtained results considerably demonstrated the relation between hand performance and vibrations due to gripping a grinder. It can be concluded that an injury or accident may happen after exposure to vibrations for the fine duties, in fast actions. PMID:29204383

  13. Hand-arm Vibration Effects on Performance, Tactile Acuity, and Temperature of Hand.

    PubMed

    Forouharmajd, Farhad; Yadegari, Mehrdad; Ahmadvand, Masoumeh; Forouharmajd, Farshad; Pourabdian, Siamak

    2017-01-01

    Effects of vibration appear as mechanical and psychological disorders, including stress reactions, cognitive and movement disorders, problem in concentration and paying attention to the assigned duties. The common signs and symptoms of hand-arm vibration (HAV) in the fingers and hands may appear as pins and needles feeling, tingling, numbness, and also the loss of finger sensation and dexterity. Laboratory Virtual Instrument Engineering Workbench programming software designed for occupational vibrations measurement was used to calculate HAV acceleration. Hole steadiness test is designed to measure involuntary movement of people. V-Pieron test is designed for one of the other aspects of the psycho motor phenomena of steadiness by moving the stylus across a V-form ruler. The two points test was an experiment of touch acuity, which used a caliper by placing the two styli very close on the pad of finger knuckles. The temperature of finger skin is also measured simultaneous to the above tests. Wilcoxon test indicated that a significant decrement in hand steadiness occurred after gripping a vibrating handle for 2 min ( P ≤ 0.003). Wilcoxon test also represented a significant change in errors after gripping a grinder vibratory handle ( P ≤ 0.003). The differences at all of the knuckles were significant with a confidence interval percentage of 99%. There was a significant reduction in finger skin temperature before and after exposure to vibration (mean = 0.45°C, based on paired sample test). The obtained results considerably demonstrated the relation between hand performance and vibrations due to gripping a grinder. It can be concluded that an injury or accident may happen after exposure to vibrations for the fine duties, in fast actions.

  14. An examination of an adapter method for measuring the vibration transmitted to the human arms

    PubMed Central

    Xu, Xueyan S.; Dong, Ren G.; Welcome, Daniel E.; Warren, Christopher; McDowell, Thomas W.

    2016-01-01

    The objective of this study is to evaluate an adapter method for measuring the vibration on the human arms. Four instrumented adapters with different weights were used to measure the vibration transmitted to the wrist, forearm, and upper arm of each subject. Each adapter was attached at each location on the subjects using an elastic cloth wrap. Two laser vibrometers were also used to measure the transmitted vibration at each location to evaluate the validity of the adapter method. The apparent mass at the palm of the hand along the forearm direction was also measured to enhance the evaluation. This study found that the adapter and laser-measured transmissibility spectra were comparable with some systematic differences. While increasing the adapter mass reduced the resonant frequency at the measurement location, increasing the tightness of the adapter attachment increased the resonant frequency. However, the use of lightweight (≤15 g) adapters under medium attachment tightness did not change the basic trends of the transmissibility spectrum. The resonant features observed in the transmissibility spectra were also correlated with those observed in the apparent mass spectra. Because the local coordinate systems of the adapters may be significantly misaligned relative to the global coordinates of the vibration test systems, large errors were observed for the adapter-measured transmissibility in some individual orthogonal directions. This study, however, also demonstrated that the misalignment issue can be resolved by either using the total vibration transmissibility or by measuring the misalignment angles to correct the errors. Therefore, the adapter method is acceptable for understanding the basic characteristics of the vibration transmission in the human arms, and the adapter-measured data are acceptable for approximately modeling the system. PMID:26834309

  15. A method for analyzing absorbed power distribution in the hand and arm substructures when operating vibrating tools

    NASA Astrophysics Data System (ADS)

    Dong, Jennie H.; Dong, Ren G.; Rakheja, Subhash; Welcome, Daniel E.; McDowell, Thomas W.; Wu, John Z.

    2008-04-01

    In this study it was hypothesized that the vibration-induced injuries or disorders in a substructure of human hand-arm system are primarily associated with the vibration power absorption distributed in that substructure. As the first step to test this hypothesis, the major objective of this study is to develop a method for analyzing the vibration power flow and the distribution of vibration power absorptions in the major substructures (fingers, palm-hand-wrist, forearm and upper arm, and shoulder) of the system exposed to hand-transmitted vibration. A five-degrees-of-freedom model of the system incorporating finger- as well as palm-side driving points was applied for the analysis. The mechanical impedance data measured at the two driving points under four different hand actions involving 50 N grip-only, 15 N grip and 35 N push, 30 N grip and 45 N push, and 50 N grip and 50 N push, were used to identify the model parameters. The vibration power absorption distributed in the substructures were evaluated using vibration spectra measured on many tools. The frequency weightings of the distributed vibration power absorptions were derived and compared with the weighting defined in ISO 5349-1 (2001). This study found that vibration power absorption is primarily distributed in the arm and shoulder when operating low-frequency tools such as rammers, while a high concentration of vibration power absorption in the fingers and hand is observed when operating high-frequency tools, such as grinders. The vibration power absorption distributed in palm-wrist and arm is well correlated with the ISO-weighted acceleration, while the finger vibration power absorption is highly correlated with unweighted acceleration. The finger vibration power absorption-based frequency weighting suggested that exposure to vibration in the frequency range of 16-500 Hz could pose higher risks of developing finger disorders. The results support the use of the frequency weighting specified in the current

  16. Vibration energy absorption (VEA) in human fingers-hand-arm system.

    PubMed

    Dong, R G; Schopper, A W; McDowell, T W; Welcome, D E; Wu, J Z; Smutz, W P; Warren, C; Rakheja, S

    2004-07-01

    A methodology for measuring the vibration energy absorbed into the fingers and the palm exposed to vibration is proposed to study the distribution of the vibration energy absorption (VEA) in the fingers-hand-arm system and to explore its potential association with vibration-induced white finger (VWF). The study involved 12 adult male subjects, constant-velocity sinusoidal excitations at 10 different discrete frequencies in the range of 16-1000 Hz, and four different hand-handle coupling conditions (finger pull-only, hand grip-only, palm push-only, and combined grip and push). The results of the study suggest that the VEA into the fingers is considerably less than that into the palm at low frequencies (< or = 25 Hz). They are, however, comparable under the excitations in the 250-1000 Hz frequency range. The finger VEA at high frequencies (> or = 100 Hz) is practically independent of the hand-handle coupling condition. The coupling conditions affect the VEA into the fingers and the palm very differently. The finger VEA results suggest that the ISO standardized frequency weighting (ISO 5349-1, 2001) may underestimate the effect of high frequency vibration on vibration-induced finger disorders. The proposed method may provide new opportunities to examine VEA and its association with VWF and other types of vibration-induced disorders in the hand-arm system.

  17. Evaluation of hand-arm and whole-body vibrations in construction and property management.

    PubMed

    Coggins, Marie A; Van Lente, Eric; McCallig, Margaret; Paddan, Gurmail; Moore, Ken

    2010-11-01

    To identify and measure the magnitude of hand-arm vibration (HAV) and whole-body vibration (WBV) sources (tools, vehicles etc.) in use within a previously unexamined sector: a construction and property management company. To evaluate the effect of factors such as age of tool, materials being worked on, number and location of tool handles, tool weight, and manufacturer brand on HAV magnitude and the effect of factors such as manufacturer machine brand, terrain, and work task on WBV magnitude. This study was carried out in a construction and property management company, employees (n = 469) working in the engineering services and maintenance departments who use vibrating equipment as part of their work were invited to participate. Two hundred and eighty-nine employees working as general operatives, excavator drivers, stone masons, carpenters, labourers, fitters, welders, and gardeners agreed to participate. A total of 20 types of hand tool (n = 264) and 11 types of vehicle (n = 158) in use within the company were selected for inclusion in the study. Five pieces of equipment had never previously been measured. Vibration measurements were carried out in accordance with ISO 5349-1 (Mechanical vibration-measurement and assessment of human exposure to hand transmitted vibration-Part 1: general guidance. 2001) (HAV) and ISO 2631-1 (Mechanical vibration and shock: evaluation of human exposure to WBV in the working environment. Part 1-general requirements. 1997) (WBV). Vibration measurements were made while workers were operating the equipment as part of their normal work activities. A wide range of vibration emission values were recorded for most tool types, e.g. orbital sanders (1.39-10.90 m s⁻²) and angle grinders (0.28-12.25 m s⁻²), and vehicle, e.g. forklifts (0.41-1.00 m s⁻²) and tractors (0.04-0.42 m s⁻²). Vibration magnitudes were largely consistent with those found in previous studies. The highest HAV magnitude was measured on a demolition hammer (13.3 m

  18. Effect of shelf aging on vibration transmissibility of anti-vibration gloves

    PubMed Central

    SHIBATA, Nobuyuki

    2017-01-01

    Anti-vibration gloves have been used in real workplaces to reduce vibration transmitted through hand-held power tools to the hand. Generally materials used for vibration attenuation in gloves are resilient materials composed of certain synthetic and/or composite polymers. The mechanical characteristics of the resilient materials used in anti-vibration gloves are prone to be influenced by environmental conditions such as temperature, humidity, and photo-irradiation, which cause material degradation and aging. This study focused on the influence of shelf aging on the vibration attenuation performance of air-packaged anti-vibration gloves following 2 yr of shelf aging. Effects of shelf aging on the vibration attenuation performance of anti-vibration gloves were examined according to the Japan industrial standard JIS T8114 test protocol. The findings indicate that shelf aging induces the reduction of vibration attenuation performance in air-packaged anti-vibration gloves. PMID:28978817

  19. Hand-arm vibration syndrome: A rarely seen diagnosis.

    PubMed

    Campbell, Rebecca A; Janko, Matthew R; Hacker, Robert I

    2017-06-01

    Hand-arm vibration syndrome (HAVS) is a collection of sensory, vascular, and musculoskeletal symptoms caused by repetitive trauma from vibration. This case report demonstrates how to diagnose HAVS on the basis of history, physical examination, and vascular imaging and its treatment options. A 41-year-old man who regularly used vibrating tools presented with nonhealing wounds on his right thumb and third digit. Arteriography revealed occlusions of multiple arteries in his hand with formation of collaterals. We diagnosed HAVS, and his wounds healed after several weeks with appropriate treatment. HAVS is a debilitating condition with often irreversible vascular damage, requiring early diagnosis and treatment.

  20. Vibration and impulsivity analysis of hand held olive beaters.

    PubMed

    Deboli, Roberto; Calvo, Angela; Preti, Christian

    2016-07-01

    To provide more effective evaluations of hand arm vibration syndromes caused by hand held olive beaters, this study focused on two aspects: the acceleration measured at the tool pole and the analysis of the impulsivity, using the crest factor. The signals were frequency weighted using the weighting curve Wh as described in the ISO 5349-1 standard. The same source signals were also filtered by the Wh-bl filter (ISO/TS 15694), because the weighting filter Wh (unlike the Wh-bl filter) could underestimate the effect of high frequency vibration on vibration-induced finger disorders. Ten (experienced) male operators used three beater models (battery powered) in the real olive harvesting condition. High vibration total values were obtained with values never lower than 20 m(-2). Concerning the crest factor, the values ranged from 5 to more than 22. This work demonstrated that the hand held olive beaters produced high impulsive loads comparable to the industry hand held tools. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  1. Validity and inter-observer reliability of subjective hand-arm vibration assessments.

    PubMed

    Coenen, Pieter; Formanoy, Margriet; Douwes, Marjolein; Bosch, Tim; de Kraker, Heleen

    2014-07-01

    Exposure to mechanical vibrations at work (e.g., due to handling powered tools) is a potential occupational risk as it may cause upper extremity complaints. However, reliable and valid assessment methods for vibration exposure at work are lacking. Measuring hand-arm vibration objectively is often difficult and expensive, while often used information provided by manufacturers lacks detail. Therefore, a subjective hand-arm vibration assessment method was tested on validity and inter-observer reliability. In an experimental protocol, sixteen tasks handling powered tools were executed by two workers. Hand-arm vibration was assessed subjectively by 16 observers according to the proposed subjective assessment method. As a gold standard reference, hand-arm vibration was measured objectively using a vibration measurement device. Weighted κ's were calculated to assess validity, intra-class-correlation coefficients (ICCs) were calculated to assess inter-observer reliability. Inter-observer reliability of the subjective assessments depicting the agreement among observers can be expressed by an ICC of 0.708 (0.511-0.873). The validity of the subjective assessments as compared to the gold-standard reference can be expressed by a weighted κ of 0.535 (0.285-0.785). Besides, the percentage of exact agreement of the subjective assessment compared to the objective measurement was relatively low (i.e., 52% of all tasks). This study shows that subjectively assessed hand-arm vibrations are fairly reliable among observers and moderately valid. This assessment method is a first attempt to use subjective risk assessments of hand-arm vibration. Although, this assessment method can benefit from some future improvement, it can be of use in future studies and in field-based ergonomic assessments. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  2. Diagnosis and treatment of hand-arm vibration syndrome and its relationship to carpal tunnel syndrome.

    PubMed

    Falkiner, Sonja

    2003-07-01

    Hand-arm vibration syndrome (HAVS) is a condition associated with the use of vibrating tools that occurs mainly in men. It consists primarily of 'occupational' Raynaud disease and digital polyneuropathy. Carpal tunnel syndrome (CTS) is also associated with hand transmitted vibration exposure and can coexist with HAVS. This article examines recent papers on causation, diagnosis, relationship to CTS and treatment. A Medline search was conducted, as was a search of UK, USA and Australian government occupational health and safety websites. Published papers that were single case studies or of poor design were not included. There are no 'gold standard' diagnostic tests for HAVS. It can mimic CTS in temperate climates and can occur with CTS. This is the diagnostic challenge when a male worker presents with apparent CTS symptoms. If he has worked with vibrating tools for many years, a diagnosis of HAVS or co-diagnosis of HAVS should be considered before a diagnosis of pure CTS is made. Nonwork risk factors for HAVS are predisposition, smoking, and exposure to vibration outside work. Cessation of exposure (and smoking) and redeployment is a critical part of treatment due to the dose response relationship of HAVS. This contrasts with adequately treated CTS, where the vast majority of workers can return to pre-injury duties. In severe cases, calcium antagonists are also used, but treatment is often ineffective. Few workplaces in Australia manage vibration risk or conduct screening to identify workers with early HAVS who should be redeployed. Local doctors have an important opportunity to diagnose HAVS and to make recommendations to the workplace on redeployment as part of treatment before symptoms become irreversible.

  3. Dose-response relation between exposure to two types of hand-arm vibration and sensorineural perception of vibration.

    PubMed

    Virokannas, H

    1995-05-01

    31 railway workers and 32 lumberjacks were examined to compare the dose-response relation between the exposure to two types of hand-arm vibration and the sensory disturbances in peripheral nerves as evaluated by the vibration perception thresholds (VPTs). Clinical examinations were carried out that included measurements of the VPTs, and electroneuromyography (ENMG), and an inquiry to confirm the use of vibrating tools. Diseases of the central nervous system and neuropathies were checked by inquiry and a clinical examination, diabetes was excluded by a blood sample analysis, and the subjects with carpal tunnel syndrome confirmed with ENMG were excluded from the study. Lifetime use of hand held tamping machines (railway workers) and chain saws (lumberjacks) had a significant correlation with the VPTs at frequencies from 32 to 500 Hz. The increase of the VPTs (250 Hz) in relation to use of vibrating tools was 1.8-fold higher on average in the whole group and 2.3-fold higher in the young (< 45) railway workers who had used hand held tamping machines, than in the corresponding groups of lumberjacks, who had used chain saws, whereas the frequency weighted acceleration of vibration in tamping machines was fourfold. There was a significant dose-response relation between the exposure to hand-arm vibration and the VPTs. The VPTs as a function of the frequency weighted acceleration of vibration and the exposure to vibration gave promising results for assessment of the risk of damage to sensory nerves induced by vibration.

  4. Thermal and vibration testing of ruggedized IR-transmitting fiber cables

    NASA Astrophysics Data System (ADS)

    Busse, Lynda; Kung, Fred; Florea, Catalin; Shaw, Brandon; Aggarwal, Ishwar; Sanghera, Jas

    2013-05-01

    We present successful results obtained for thermal/ vibration testing of ruggedized, IR-transmitting chalcogenide glass fiber cables using a government facility with state-of-the-art equipment capable of MIL-SPEC environmental testing. We will also present results of a direct imprinting process to create novel "moth eye" patterned surfaces on the IR fiber cable ends that significantly reduces endface reflection losses from 17% to less than 3%. The cables with these imprinted "moth eye" ends transmit much higher IR laser power without damage than was obtained for previous cables with traditional AR coatings.

  5. Assessment of coarse and fine hand motor performance in asymptomatic subjects exposed to hand-arm vibration.

    PubMed

    Popević, Martin B; Janković, Srđan M; Borjanović, Srđan S; Jovičić, Slavica R; Tenjović, Lazar R; Milovanović, Aleksandar P S; Bulat, Petar

    2014-03-01

    A frequently encountered exposure profile for hand-arm vibration in contemporary occupational setting comprises workers with a long history of intermittent exposure but without detectable signs of hand-arm vibration syndrome (HAVS). Yet, most of the published studies deal with developed HAVS cases, rarely discussing the biological processes that may be involved in degradation of manual dexterity and grip strength when it can be most beneficial - during the asymptomatic stage. In the present paper, a group of 31 male asymptomatic vibration-exposed workers (according to the Stockholm Workshop Scale) were compared against 30 male controls. They were tested using dynamometry and dexterimetry (modelling coarse and fine manual performance respectively) and cold provocation was done to detect possible differences in manual performance drop on these tests. The results showed reduced manual dexterity but no significant degradation in hand grip strength in the exposed subjects. This suggests that intermittent exposure profile and small cumulative vibration dose could only lead to a measurable deficit in manual dexterity but not hand grip strength even at non-negligible A(8) levels and long term exposures.

  6. Dose-response relation between exposure to two types of hand-arm vibration and sensorineural perception of vibration.

    PubMed Central

    Virokannas, H

    1995-01-01

    OBJECTIVES--31 railway workers and 32 lumberjacks were examined to compare the dose-response relation between the exposure to two types of hand-arm vibration and the sensory disturbances in peripheral nerves as evaluated by the vibration perception thresholds (VPTs). METHODS--Clinical examinations were carried out that included measurements of the VPTs, and electroneuromyography (ENMG), and an inquiry to confirm the use of vibrating tools. Diseases of the central nervous system and neuropathies were checked by inquiry and a clinical examination, diabetes was excluded by a blood sample analysis, and the subjects with carpal tunnel syndrome confirmed with ENMG were excluded from the study. RESULTS--Lifetime use of hand held tamping machines (railway workers) and chain saws (lumberjacks) had a significant correlation with the VPTs at frequencies from 32 to 500 Hz. The increase of the VPTs (250 Hz) in relation to use of vibrating tools was 1.8-fold higher on average in the whole group and 2.3-fold higher in the young (< 45) railway workers who had used hand held tamping machines, than in the corresponding groups of lumberjacks, who had used chain saws, whereas the frequency weighted acceleration of vibration in tamping machines was fourfold. CONCLUSION--There was a significant dose-response relation between the exposure to hand-arm vibration and the VPTs. The VPTs as a function of the frequency weighted acceleration of vibration and the exposure to vibration gave promising results for assessment of the risk of damage to sensory nerves induced by vibration. PMID:7795756

  7. Experiences and consequences for women with hand-arm vibration injuries.

    PubMed

    Bylund, Sonya Hörnqwist; Ahlgren, Christina

    2010-01-01

    Vibrating machines are used in a variety of occupations. Exposure to hand-arm vibration can cause vascular, neurological, and muscular symptoms in the hands and arms. This qualitative study provides a deeper understanding of the consequences of vibration injuries in women. In depth interviews were conducted with eight women with vibration injuries. The women were metal and wood product assemblers and dental personnel. The transcribed interviews were analyzed in accordance with the grounded theory method. The core category in the findings was "another life". This was constructed by the categories "consequences for everyday activities", "work performance", "household duties", "leisure", and "self perception" and shows that the injury had affected most parts of the women's lives and decreased their quality of life. The importance of well-functioning hands in all activities was highlighted. Reduced hand function due to numbness, muscle weakness, and pain caused restricted abilities to perform activities at work, at home, and during leisure time. The women described impact on their self-perception, as the injury had affected them in their roles as a worker, mother, and woman. The findings indicate that a vibration injury is a multidimensional problem that can affect every aspect of an individual's life. Health care providers should be aware of these complex consequences.

  8. Determinants explaining the variability of hand-transmitted vibration emissions from two different work tasks: grinding and cutting using angle grinders.

    PubMed

    Liljelind, Ingrid; Pettersson, Hans; Nilsson, Leif; Wahlström, Jens; Toomingas, Allan; Lundström, Ronnie; Burström, Lage

    2013-10-01

    There are numerous factors including physical, biomechanical, and individual that influence exposure to hand-transmitted vibration (HTV) and cause variability in the exposure measurements. Knowledge of exposure variability and determinants of exposure could be used to improve working conditions. We performed a quasi-experimental study, where operators performed routine work tasks in order to obtain estimates of the variance components and to evaluate the effect of determinants, such as machine-wheel combinations and individual operator characteristics. Two pre-defined simulated work tasks were performed by 11 operators: removal of a weld puddle of mild steel and cutting of a square steel pipe. In both tasks, four angle grinders were used, two running on compressed air and two electrically driven. Two brands of both grinding and cutting wheels were used. Each operator performed both tasks twice in a random order with each grinder and wheel and the time to complete each task was recorded. Vibration emission values were collected and the wheel wear was measured as loss of weight. Operators' characteristics collected were as follows: age, body height and weight, length and volume of their hands, maximum hand grip force, and length of work experience with grinding machines (years). The tasks were also performed by one operator who used four machines of the same brand. Mixed and random effects models were used in the statistical evaluation. The statistical evaluation was performed for grinding and cutting separately and we used a measure referring to the sum of the 1-s r.m.s. average frequency-weighted acceleration over time for completing the work task (a(sa)). Within each work task, there was a significant effect as a result of the determinants 'the machine used', 'wheel wear', and 'time taken to complete the task'. For cutting, 'the brand of wheel' used also had a significant effect. More than 90% of the inherent variability in the data was explained by the

  9. Anti-vibration gloves?

    PubMed

    Hewitt, Sue; Dong, Ren G; Welcome, Daniel E; McDowell, Thomas W

    2015-03-01

    For exposure to hand-transmitted vibration (HTV), personal protective equipment is sold in the form of anti-vibration (AV) gloves, but it remains unclear how much these gloves actually reduce vibration exposure or prevent the development of hand-arm vibration syndrome in the workplace. This commentary describes some of the issues that surround the classification of AV gloves, the assessment of their effectiveness and their applicability in the workplace. The available information shows that AV gloves are unreliable as devices for controlling HTV exposures. Other means of vibration control, such as using alternative production techniques, low-vibration machinery, routine preventative maintenance regimes, and controlling exposure durations are far more likely to deliver effective vibration reductions and should be implemented. Furthermore, AV gloves may introduce some adverse effects such as increasing grip force and reducing manual dexterity. Therefore, one should balance the benefits of AV gloves and their potential adverse effects if their use is considered. © Crown copyright 2014.

  10. Test-retest reliability of neurophysiological tests of hand-arm vibration syndrome in vibration exposed workers and unexposed referents.

    PubMed

    Gerhardsson, Lars; Gillström, Lennart; Hagberg, Mats

    2014-01-01

    Exposure to hand-held vibrating tools may cause the hand-arm vibration syndrome (HAVS). The aim was to study the test-retest reliability of hand and muscle strength tests, and tests for the determination of thermal and vibration perception thresholds, which are used when investigating signs of neuropathy in vibration exposed workers. In this study, 47 vibration exposed workers who had been investigated at the department of Occupational and Environmental Medicine in Gothenburg were compared with a randomized sample of 18 unexposed subjects from the general population of the city of Gothenburg. All participants passed a structured interview, answered several questionnaires and had a physical examination including hand and finger muscle strength tests, determination of vibrotactile (VPT) and thermal perception thresholds (TPT). Two weeks later, 23 workers and referents, selected in a randomized manner, were called back for the same test-procedures for the evaluation of test-retest reliability. The test-retest reliability after a two week interval expressed as limits of agreement (LOA; Bland-Altman), intra-class correlation coefficients (ICC) and Pearson correlation coefficients was excellent for tests with the Baseline hand grip, Pinch-grip and 3-Chuck grip among the exposed workers and referents (N = 23: percentage of differences within LOA 91 - 100%; ICC-values ≥0.93; Pearson r ≥0.93). The test-retest reliability was also excellent (percentage of differences within LOA 96-100 %) for the determination of vibration perception thresholds in digits 2 and 5 bilaterally as well as for temperature perception thresholds in digits 2 and 5, bilaterally (percentage of differences within LOA 91 - 96%). For ICC and Pearson r the results for vibration perception thresholds were good for digit 2, left hand and for digit 5, bilaterally (ICC ≥ 0.84; r ≥0.85), and lower (ICC = 0.59; r = 0.59) for digit 2, right hand. For the latter two indices the test

  11. Hand-arm vibration syndrome: What family physicians should know.

    PubMed

    Shen, Shixin Cindy; House, Ronald A

    2017-03-01

    To provide family physicians with an understanding of the epidemiology, pathogenesis, symptoms, diagnosis, and management of hand-arm vibration syndrome (HAVS), an important and common occupational disease in Canada. A MEDLINE search was conducted for research and review articles on HAVS. A Google search was conducted to obtain gray literature relevant to the Canadian context. Additional references were obtained from the articles identified. Hand-arm vibration syndrome is a prevalent occupational disease affecting workers in multiple industries in which vibrating tools are used. However, it is underdiagnosed in Canada. It has 3 components-vascular, in the form of secondary Raynaud phenomenon; sensorineural; and musculoskeletal. Hand-arm vibration syndrome in its more advanced stages contributes to substantial disability and poor quality of life. Its diagnosis requires careful history taking, in particular occupational history, physical examination, laboratory tests to rule out alternative diagnoses, and referral to an occupational medicine specialist for additional investigations. Management involves reduction of vibration exposure, avoidance of cold conditions, smoking cessation, and medication. To ensure timely diagnosis of HAVS and improve prognosis and quality of life, family physicians should be aware of this common occupational disease and be able to elicit the relevant occupational history, refer patients to occupational medicine clinics, and appropriately initiate compensation claims. Copyright© the College of Family Physicians of Canada.

  12. Vibrotactile perception and effects of short-term exposure to hand-arm vibration.

    PubMed

    Burström, Lage; Lundström, Ronnie; Hagberg, Mats; Nilsson, Tohr

    2009-07-01

    This study clarifies whether the established frequency weighting procedure for evaluating exposure to hand-transmitted vibration can effectively evaluate the temporary changes in vibrotactile perception thresholds due to pre-exposure to vibration. In addition, this study investigates the relationship between changes of the vibrotactile perception thresholds and the normalized energy-equivalent frequency-weighted acceleration. The fingers of 10 healthy subjects, five male and five female, were exposed to vibration under 16 conditions with a combination of different frequencies, intensities, and exposure times. The vibration frequencies were 31.5 and 125 Hz and exposure lasted between 2 and 16 min. According to International Organization for Standardization (ISO) 5349-1, the energy-equivalent frequency-weighted acceleration for the experimental time of 16 min is 2.5 or 5.0 m s(-2) root-mean-square, corresponding to a 8-h equivalent acceleration, A(8), of approximately 0.5 and 0.9 m s(-2), respectively. A measure of the vibrotactile perception thresholds was conducted before the different exposures to vibration. Immediately after the vibration exposure, the acute effect was measured continuously on the exposed index finger for the first 75 s, followed by 30 s of measures every minute for a maximum of 10 min. If the subject's thresholds had not recovered, the measures continued for a maximum of 30 min with measurements taken every 5 min. Pre-exposure to vibration significantly influenced vibrotactile thresholds. This study concludes that the influence on the thresholds depends on the frequency of the vibration stimuli. Increased equivalent frequency-weighted acceleration resulted in a significant change in threshold, but the thresholds were unaffected when changes in the vibration magnitude were expressed as the frequency-weighted acceleration or the unweighted acceleration. Moreover, the frequency of the pre-vibration exposure significantly influenced (up to 25 min

  13. Tremor and hand-arm vibration syndrome (HAVS) in road maintenance workers.

    PubMed

    Bast-Pettersen, Rita; Ulvestad, Bente; Færden, Karl; Clemm, Thomas Aleksander C; Olsen, Raymond; Ellingsen, Dag Gunnar; Nordby, Karl-Christian

    2017-01-01

    The aim of this study was to evaluate postural and rest tremor among workers using vibrating hand tools, taking into account the possible effects of toxicants such as alcohol and tobacco. A further aim was to study workers diagnosed with hand-arm vibration syndrome (HAVS) at the time of examination. This study comprises 103 road maintenance workers, 55 exposed to vibrating hand tools (age 41.0 years; range 21-62) and 48 referents (age 38.5 years; range 19-64). They were examined with the CATSYS Tremor Pen ® . Exposure to vibrating tools and serum biomarkers of alcohol and tobacco consumption were measured. Cumulative exposure to vibrating tools was associated with increased postural (p < 0.01) and rest tremor (p < 0.05) and with a higher Center Frequency of postural tremor (p < 0.01) among smokers and users of smokeless tobacco. Rest tremor Center Frequency was higher than postural tremor frequency (p < 0.001). The main findings indicate an association between cumulative exposure to hand-held vibrating tools, tremor parameters and consumption of tobacco products. The hand position is important when testing for tremor. Rest tremor had a higher Center Frequency. Postural tremor was more strongly associated with exposure than rest tremor. The finding of increased tremor among the HAVS subjects indicated that tremor might be a part of the clinical picture of a HAVS diagnosis. As with all cross-sectional studies, inferences should be made with caution when drawing conclusions about associations between exposure and possible effects. Future research using longitudinal design is required to validate the findings of the present study.

  14. Control Model for Dampening Hand Vibrations Using Information of Internal and External Coordinates

    PubMed Central

    Togo, Shunta; Kagawa, Takahiro; Uno, Yoji

    2015-01-01

    In the present study, we investigate a control mechanism that dampens hand vibrations. Here, we propose a control method with two components to suppress hand vibrations. The first is a passive suppression method that lowers the joint stiffness to passively dampen the hand vibrations. The second is an active suppression method that adjusts an equilibrium point based on skyhook control to actively dampen the hand vibrations. In a simulation experiment, we applied these two methods to dampen hand vibrations during the shoulder’s horizontal oscillation. We also conducted a measurement experiment wherein a subject’s shoulder was sinusoidally oscillated by a platform that generated horizontal oscillations. The results of the measurement experiments showed that the jerk of each part of the arm in a task using a cup filled with water was smaller than the shoulder jerk and that in a task with a cup filled with stones was larger than the shoulder jerk. Moreover, the amplitude of the hand trajectory in both horizontal and vertical directions was smaller in a task using a cup filled with water than in a task using a cup filled with stones. The results of the measurement experiments were accurately reproduced by the active suppression method based on skyhook control. These results suggest that humans dampen hand vibrations by controlling the equilibrium point through the information of the external workspace and the internal body state rather than by lowering joint stiffness only by using internal information. PMID:25876037

  15. Hand-arm vibration syndrome and dose-response relation for vibration induced white finger among quarry drillers and stonecarvers. Italian Study Group on Physical Hazards in the Stone Industry.

    PubMed Central

    Bovenzi, M

    1994-01-01

    limits for the protection of workers against the harmful effects of hand transmitted vibration. PMID:7951792

  16. Hand-arm vibration in tropical rain forestry workers.

    PubMed

    Futatsuka, M; Inaoka, T; Ohtsuka, R; Sakurai, T; Moji, K; Igarashi, T

    1995-01-01

    Working conditions and health hazards including vibration syndrome related to forestry work using chain-saws were studied in Papua New Guinea and Indonesia. The subjects comprised 291 workers including 97 chain-saw operators. The health examination consisted of peripheral circulatory and sensory tests in the upper extremities. The vibration spectrum measured at the handle of the chain-saw indicated that these acceleration levels would lead to a moderately high risk of hand-arm vibration syndrome (HAVS). The peripheral circulatory function tests revealed dysfunction after more than five years vibration exposure. However, in general, the results of the function tests and subjective complaints showed fewer health problems compared to those of Japanese forestry workers. The reason of such differences of vibration effects seem to be the following: (1) warmer climate (more than 25 degrees C throughout the year), (2) young workers and short work experience. (3) short time vibration exposures on working days in the natural forests, (4) seasonal changes in logging work (5) healthy workers effects. Thus, we found no clear evidence that the workers of our study suffered from HAVS. A principal component analysis was applied. The factor score of the components of the reactive dynamics of peripheral circulation differed significantly after more than five years' exposure. On the other hand, we cannot deny the possibility that subclinical dysfunction of peripheral circulation may be caused by chain-saw operation in the tropics in future. Further investigations on the HAVS among forestry workers in the tropic environment are needed.

  17. Vibration-induced multifocal neuropathy in forestry workers: electrophysiological findings in relation to vibration exposure and finger circulation.

    PubMed

    Bovenzi, M; Giannini, F; Rossi, S

    2000-11-01

    To investigate neural conduction in the upper limbs of symptomatic forestry workers with and without exposure to hand-transmitted vibration. A further aim was to assess the possible relationships between vibration exposure, nerve conduction and finger circulation in the forestry workers who used chain saws. A detailed neurophysiological investigation was performed on the upper extremities of 20 chain saw workers, 20 forestry operators with heavy manual work but without vibration exposure, and 20 healthy male controls. All subjects were screened to exclude polyneuropathy. Measurements of sensory and motor nerve conduction (velocity and amplitude) were obtained bilaterally from the median, ulnar and radial nerves. To assess peripheral vascular function, the forestry workers underwent a cold test with plethysmographic measurement of finger systolic blood pressure (FSBP). In the chain saw operators, vibration exposure was evaluated according to the International Standard ISO 5349. Indices of daily vibration exposure and lifetime cumulative vibration dose were estimated for each chain saw operator. Sensory nerve conduction in several segments of the median and radial nerves was significantly reduced in the chain saw operators compared with that in the workers doing heavy manual work and the controls. The neurophysiological pattern more frequently observed in the chain saw operators was a multifocal nerve conduction impairment to several neural segments with predominant involvement of sensory rather than motor fibres. Sensory nerve conduction velocities in the hands of the chain saw operators were inversely related to both daily and lifetime cumulative vibration exposures. In the vibration-exposed forestry workers, neither were sensori-motor complaints associated with vascular symptoms (finger whiteness) nor were electrophysiological data related to cold-induced changes in FSBP. Exposure to hand-transmitted vibration, in addition to ergonomic stress factors, can

  18. The Effect of a Mechanical Arm System on Portable Grinder Vibration Emissions

    PubMed Central

    McDowell, Thomas W.; Welcome, Daniel E.; Warren, Christopher; Xu, Xueyan S.; Dong, Ren G.

    2016-01-01

    Mechanical arm systems are commonly used to support powered hand tools to alleviate ergonomic stressors related to the development of workplace musculoskeletal disorders. However, the use of these systems can increase exposure times to other potentially harmful agents such as hand-transmitted vibration. To examine how these tool support systems affect tool vibration, the primary objectives of this study were to characterize the vibration emissions of typical portable pneumatic grinders used for surface grinding with and without a mechanical arm support system at a workplace and to estimate the potential risk of the increased vibration exposure time afforded by the use of these mechanical arm systems. This study also developed a laboratory-based simulated grinding task based on the ISO 28927-1 (2009) standard for assessing grinder vibrations; the simulated grinding vibrations were compared with those measured during actual workplace grinder operations. The results of this study demonstrate that use of the mechanical arm may provide a health benefit by reducing the forces required to lift and maneuver the tools and by decreasing hand-transmitted vibration exposure. However, the arm does not substantially change the basic characteristics of grinder vibration spectra. The mechanical arm reduced the average frequency-weighted acceleration by about 24% in the workplace and by about 7% in the laboratory. Because use of the mechanical arm system can increase daily time-on-task by 50% or more, the use of such systems may actually increase daily time-weighted hand-transmitted vibration exposures in some cases. The laboratory acceleration measurements were substantially lower than the workplace measurements, and the laboratory tool rankings based on acceleration were considerably different than those from the workplace. Thus, it is doubtful that ISO 28927-1 is useful for estimating workplace grinder vibration exposures or for predicting workplace grinder acceleration rank

  19. Improving hand sensibility in vibration induced neuropathy: A case-series.

    PubMed

    Rosén, Birgitta; Björkman, Anders; Lundborg, Göran

    2011-04-27

    We report a long-term series of nine workers suffering from vibration-induced neuropathy, after many years of exposure to hand-held vibrating tools at high or low frequency. They were treated with temporary selective cutaneous anaesthesia (EMLA® cream) of the forearm repeatedly for a period up to one year (in two cases four years). The aim was to improve their capacity to perceive touch and thereby improve hand function and diminish disability. The treatment principle is based on current concepts of brain plasticity, where a deafferentation of a skin area results in improved sensory function in adjacent skin areas. All participants had sensory hand problems in terms of numbness (median touch thresholds > 70 mg) and impaired hand function influencing ADL (mean DASH score 22).After an initial identical self-administered treatment period of 8 weeks (12-15 treatments with increasing intervals) they did one treatment every 2-3 month. After one year sensibility (touch thresholds and tactile discrimination) as well as hand function (mean DASH score 13) were improved in a majority of the cases. Seven of the participants choose to continue the treatment after the first year and two of them have continued at a regular basis for up to four years. A surprising, secondary finding was diminishing nocturnal numbness of the hand and arm in eight of the nine subjects from "frequently" to "hardly ever or never". Our observations open new perspectives for treatment of impaired sensibility and hand function in a group of patients with vibration induced hand problems where we have no treatment to offer today.

  20. Improving hand sensibility in vibration induced neuropathy: A case-series

    PubMed Central

    2011-01-01

    Objectives We report a long-term series of nine workers suffering from vibration-induced neuropathy, after many years of exposure to hand-held vibrating tools at high or low frequency. They were treated with temporary selective cutaneous anaesthesia (EMLA® cream) of the forearm repeatedly for a period up to one year (in two cases four years). The aim was to improve their capacity to perceive touch and thereby improve hand function and diminish disability. The treatment principle is based on current concepts of brain plasticity, where a deafferentation of a skin area results in improved sensory function in adjacent skin areas. Methods All participants had sensory hand problems in terms of numbness (median touch thresholds > 70 mg) and impaired hand function influencing ADL (mean DASH score 22). After an initial identical self-administered treatment period of 8 weeks (12-15 treatments with increasing intervals) they did one treatment every 2-3 month. Results After one year sensibility (touch thresholds and tactile discrimination) as well as hand function (mean DASH score 13) were improved in a majority of the cases. Seven of the participants choose to continue the treatment after the first year and two of them have continued at a regular basis for up to four years. A surprising, secondary finding was diminishing nocturnal numbness of the hand and arm in eight of the nine subjects from "frequently" to "hardly ever or never". Conclusions Our observations open new perspectives for treatment of impaired sensibility and hand function in a group of patients with vibration induced hand problems where we have no treatment to offer today. PMID:21524297

  1. A cross sectional study on hand-arm vibration syndrome among a group of tree fellers in a tropical environment.

    PubMed

    Su, Anselm Ting; Maeda, Setsuo; Fukumoto, Jin; Miyai, Nobuyuki; Isahak, Marzuki; Yoshioka, Atsushi; Nakajima, Ryuichi; Bulgiba, Awang; Miyashita, Kazuhisa

    2014-01-01

    This study aimed to explore the clinical characteristics of hand arm vibration syndrome (HAVS) in a group of tree fellers in a tropical environment. We examined all tree fellers and selected control subjects in a logging camp of central Sarawak for vibration exposure and presence of HAVS symptoms utilizing vibrotactile perception threshold test (VPT) and cold water provocation test (CWP). None of the subjects reported white finger. The tree fellers reported significantly higher prevalence of finger coldness as compared to the control subjects (OR=10.32, 95%CI=1.21-87.94). A lower finger skin temperature, longer fingernail capillary return time and higher VPT were observed among the tree fellers as compared to the control subjects in all fingers (effect size >0.5). The VPT following CWP of the tree fellers was significantly higher (repeated measures ANOVA p=0.002, partial η(2)=0.196) than the control subject. The A (8) level was associated with finger tingling, numbness and dullness (effect size=0.983) and finger coldness (effect size=0.524) among the tree fellers. Finger coldness and finger tingling, numbness and dullness are important symptoms for HAVS in tropical environment that may indicate vascular and neurological damage due to hand-transmitted vibration exposure.

  2. Frequency weightings based on biodynamics of fingers-hand-arm system.

    PubMed

    Dong, Ren G; Welcome, Daniel E; Wu, John Z

    2005-07-01

    The frequency weighting for assessing hand-transmitted vibration exposure is critical to obtaining a true dose-response relationship. Any valid weighting must have a solid theoretical foundation. The objectives of this study are to examine the biodynamic foundation for assessing the vibration exposure and to develop a set of biodynamic methods to formulate the frequency weightings for different anatomical locations of the fingers-hand-arm system. The vibration transmissibility measured on the fingers, hand, wrist, elbow, shoulder, and head was used to define the transmitted acceleration-based (TAB) frequency weighting. The apparent masses measured at the fingers and the palm of the hand were used to construct the biodynamic force-based (BFB) weightings. These weightings were compared with the ISO weighting specified in ISO 5349-1 (2001). The results of this study suggest that the frequency weightings for the vibration-induced problems at different anatomical locations of the hand-arm system can be basically divided into three groups: (a) the weighting for the fingers and hand, (b) the weighting for the wrist, elbow, and shoulder, and (c) the weighting for the head. The ISO weighting is highly correlated with the weighting for the second group but not with the first and third groups. The TAB and BFB finger weightings are quite different at frequencies lower than 100 Hz, but they show similar trends at higher frequencies. Both TAB and BFB finger weightings at frequencies higher than 20 Hz are greater than the ISO weighting.

  3. [Carpal canal ultrasound examination in patients with mild hand-arm vibration disease].

    PubMed

    Liu, Y Z; Ye, Z H; Yang, W L; Zhu, J X; Lu, Q J; Su, W L

    2016-08-20

    Objective: To investigate the clinical value of ultrasound examination of carpal canal structure in patients with mild hand-arm vibration disease. Methods: A total of 29 patients (58 wrists) with mild hand-arm vibration disease who were treated in Shenzhen Prevention and Treatment Center for Occupational Diseases from May to December, 2015 were enrolled as observation group, and 20 healthy volunteers (40 wrists) were enrolled as the control group. Color Doppler ultrasound was used to observe the morphology and echo of the median nerve in the carpal canal and 9 muscle tendons and transverse carpal ligament. The thickness of transverse carpal ligament and diameter of the median nerve at the level of the hamulus of hamate bone were measured, as well as the cross-sectional area of the median nerve at the level of pisiform bone. Results: In the 29 patients with hand-arm vibration disease patients in the observation group, 8 experienced entrapment of the median nerve in the carpal canal, among whom 5 had entrapment in both wrists; there were 13 wrists (23%) with nerve entrapment and 45 wrists (77%) without nerve entrapment. Compared with the control group, the patients with hand-arm vibration disease and nerve entrapment in the observation group showed significant thickening of the transverse carpal ligament at the level of the hamulus of hamate bone and a significant increase in the cross-sectional area of the median nerve at the level of pisiform bone ( P <0.05) , while there were no significant differences in the thickness of transverse carpal ligament at the level of the hamulus of hamate bone and the cross-sectional area of the median nerve at the level of pisiform bone ( t=- 9.397 and -4.385, both P >0.05) . Conclusion: Ultrasound examination can clearly show the radiological changes of carpal canal contents in patients with mild hand-arm vibration disease and has a certain diagnostic value in nerve damage in patients with hand-arm vibration disease.

  4. Hand-arm vibration exposure monitoring with wearable sensor module.

    PubMed

    Austad, Hanne O; Røed, Morten H; Liverud, Anders E; Dalgard, Steffen; Seeberg, Trine M

    2013-01-01

    Vibration exposure is a serious risk within work physiology for several work groups. Combined with cold artic climate, the risk for permanent harm is even higher. Equipment that can monitor the vibration exposure and warn the user when at risk will provide a safer work environment for these work groups. This study evaluates whether data from a wearable wireless multi-parameter sensor module can be used to estimate vibration exposure and exposure time. This work has been focused on the characterization of the response from the accelerometer in the sensor module and the optimal location of the module in the hand-arm configuration.

  5. [The combined use of capillaroscopy and skin thermometry in health surveillance of workers exposed to hand-arm vibration].

    PubMed

    Riolfi, A; Perbellini, L

    2010-01-01

    The use of nailfold capillaroscopy combined with skin thermometry in the study of microcirculation of the hands in workers exposed to hand-arm vibration is assessed. Fifty-eight subjects were studied; 40 asymptomatic forestry workers exposed to hand-arm vibration, 13 forestry workers exposed to hand-arm vibration with Raynaud-like symptoms confirmed by skin thermometry; 5 controls. Reduction of capillary density was observed in workers exposed to vibrating tools with respect to controls. Tortuosity of capillary loops was significantly more frequent in subjects exposed to vibrating tools than in controls. No statistically significant difference in capillary vessels of the hands was found between asymptomatic exposed subjects and workers affected by Raynaud-like symptoms. In our sample nailfold capillaroscopy shows good sensibilty and specificity in detecting capillary modifications secondary to exposure to hand-vibration. Weaker evidence is instead given in order to actual disturbances of hands circulation in chronic exposure to vibrating tools.

  6. The Effect of a Mechanical Arm System on Portable Grinder Vibration Emissions.

    PubMed

    McDowell, Thomas W; Welcome, Daniel E; Warren, Christopher; Xu, Xueyan S; Dong, Ren G

    2016-04-01

    Mechanical arm systems are commonly used to support powered hand tools to alleviate ergonomic stressors related to the development of workplace musculoskeletal disorders. However, the use of these systems can increase exposure times to other potentially harmful agents such as hand-transmitted vibration. To examine how these tool support systems affect tool vibration, the primary objectives of this study were to characterize the vibration emissions of typical portable pneumatic grinders used for surface grinding with and without a mechanical arm support system at a workplace and to estimate the potential risk of the increased vibration exposure time afforded by the use of these mechanical arm systems. This study also developed a laboratory-based simulated grinding task based on the ISO 28927-1 (2009) standard for assessing grinder vibrations; the simulated grinding vibrations were compared with those measured during actual workplace grinder operations. The results of this study demonstrate that use of the mechanical arm may provide a health benefit by reducing the forces required to lift and maneuver the tools and by decreasing hand-transmitted vibration exposure. However, the arm does not substantially change the basic characteristics of grinder vibration spectra. The mechanical arm reduced the average frequency-weighted acceleration by about 24% in the workplace and by about 7% in the laboratory. Because use of the mechanical arm system can increase daily time-on-task by 50% or more, the use of such systems may actually increase daily time-weighted hand-transmitted vibration exposures in some cases. The laboratory acceleration measurements were substantially lower than the workplace measurements, and the laboratory tool rankings based on acceleration were considerably different than those from the workplace. Thus, it is doubtful that ISO 28927-1 is useful for estimating workplace grinder vibration exposures or for predicting workplace grinder acceleration rank

  7. Acute effects of vibration from a chipping hammer and a grinder on the hand-arm system.

    PubMed Central

    Kihlberg, S; Attebrant, M; Gemne, G; Kjellberg, A

    1995-01-01

    OBJECTIVES--The purpose of this study was to compare various effects on the hand-arm system of vibration exposure from a chipping hammer and a grinder with the same frequency weighted acceleration. Grip and push forces were measured and monitored during the exposure. The various effects were: muscle activity (measured with surface electrodes), discomfort ratings for different parts of the hand-arm system (made during and after exposure), and vibration perception threshold (for 10 minutes before and 10 minutes after the exposure). RESULTS--No increase in muscle activity due to exposure to vibration was found in the hand muscle studied. In the forearm, conversely, there was an increase in both muscle studied. For the upper arm the muscle activity only increased when exposed to impact vibration. Subjective ratings in the hand and shift in vibration perception threshold were effected more by the grinder than the hammer exposure. CONCLUSION--These results show that the reaction of the hand-arm system to vibration varies with frequency quantitatively as well as qualitatively. They do not support the notion that one single frequency weighted curve would be valid for the different health effects of hand-arm vibration (vascular, musculoskeletal, neurological, and psychophysiological). PMID:8535492

  8. Exposure assessment in health assessments for hand-arm vibration syndrome.

    PubMed

    Mason, H J; Poole, K; Young, C

    2011-08-01

    Assessing past cumulative vibration exposure is part of assessing the risk of hand-arm vibration syndrome (HAVS) in workers exposed to hand-arm vibration and invariably forms part of a medical assessment of such workers. To investigate the strength of relationships between the presence and severity of HAVS and different cumulative exposure metrics obtained from a self-reporting questionnaire. Cumulative exposure metrics were constructed from a tool-based questionnaire applied in a group of HAVS referrals and workplace field studies. These metrics included simple years of vibration exposure, cumulative total hours of all tool use and differing combinations of acceleration magnitudes for specific tools and their daily use, including the current frequency-weighting method contained in ISO 5349-1:2001. Use of simple years of exposure is a weak predictor of HAVS or its increasing severity. The calculation of cumulative hours across all vibrating tools used is a more powerful predictor. More complex calculations based on involving likely acceleration data for specific classes of tools, either frequency weighted or not, did not offer a clear further advantage in this dataset. This may be due to the uncertainty associated with workers' recall of their past tool usage or the variability between tools in the magnitude of their vibration emission. Assessing years of exposure or 'latency' in a worker should be replaced by cumulative hours of tool use. This can be readily obtained using a tool-pictogram-based self-reporting questionnaire and a simple spreadsheet calculation.

  9. Examining the Usefulness of ISO 10819 Anti-Vibration Glove Certification.

    PubMed

    Budd, Diandra; House, Ron

    2017-03-01

    Anti-vibration gloves are commonly worn to reduce hand-arm vibration exposure from work with hand-held vibrating tools when higher priority and more effective controls are unavailable. For gloves to be marketed as 'anti-vibration' they must meet the vibration transmissibility criteria described in the International Organization for Standardization (ISO) standard 10819 (2013). Several issues exist with respect to the methodology used for glove testing as well as the requirements for glove design and composition in ISO 10819 (2013). The true usefulness of anti-vibration gloves at preventing hand-arm vibration syndrome (HAVS) is controversial, given that their performance is dependent on tool vibration characteristics and the anthropometrics of workers in real working conditions. The major risk associated with the use of anti-vibration gloves is that it will give employees and employers a false sense of protection against the negative effects of hand-transmitted vibration. This commentary examines the limitations of the current international standards for anti-vibration glove testing and certification, thereby calling into question the degree of protection that anti-vibration gloves provide against HAVS, and cautioning users to consider both their benefits and potential drawbacks on a case-by-case basis. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  10. Hand-arm vibration syndrome in South African gold miners.

    PubMed

    Nyantumbu, Busi; Barber, Chris M; Ross, Mary; Curran, Andrew D; Fishwick, David; Dias, Belinda; Kgalamono, Spo; Phillips, James I

    2007-01-01

    Hand-arm vibration syndrome (HAVS) is associated with the use of hand-held vibrating tools. Affected workers may experience symptoms of tingling, numbness, loss of grip strength and pain. Loss of dexterity may impair everyday activities, and potentially increase the risk of occupational accidents. Although high vibration levels (up to 31 m/s(2)) have been measured in association with rock drills, HAVS has not been scientifically evaluated in the South African mining industry. The aim of this study was to determine the prevalence and severity of HAVS in South African gold miners, and to identify the tools responsible. A cross-sectional study was conducted in a single South African gold-mine. Participants were randomly selected from mineworkers returning from annual leave, comprising 156 subjects with occupational exposure to vibration, and 140 workers with no exposure. Miners who consented to participate underwent a clinical HAVS assessment following the UK Health and Safety Laboratory protocol. The prevalence of HAVS in vibration-exposed gold miners was 15%, with a mean latent period of 5.6 years. Among the non-exposed comparison group, 5% had signs and symptoms indistinguishable from HAVS. This difference was statistically significant (P < 0.05). All the cases of HAVS gave a history of exposure to rock drills. The study has diagnosed the first cases of HAVS in the South African mining industry. The prevalence of HAVS was lower than expected, and possible explanations for this may include a survivor population, and lack of vascular symptom reporting due to warm-ambient temperatures.

  11. Transmission of vibration through gloves: effects of material thickness.

    PubMed

    Md Rezali, Khairil Anas; Griffin, Michael J

    2016-08-01

    It might be assumed that increasing the thickness of a glove would reduce the vibration transmitted to the hand. Three material samples from an anti-vibration glove were stacked to produce three thicknesses: 6.4, 12.8 and 19.2 mm. The dynamic stiffnesses of all three thicknesses, the apparent mass at the palm and the finger and the transmission of vibration to the palm and finger were measured. At frequencies from 20 to 350 Hz, the material reduced vibration at the palm but increased vibration at the finger. Increased thickness reduced vibration at the palm but increased vibration at the finger. The measured transmissibilities could be predicted from the material dynamic stiffness and the apparent mass of the palm and finger. Reducing the dynamic stiffness of glove material may increase or decrease the transmission of vibration, depending on the material, the frequency of vibration and the location of measurement (palm or finger). Practitioner Summary: Transmission of vibration through gloves depends on the dynamic response of the hand and the dynamic stiffness of glove material, which depends on material thickness. Measuring the transmission of vibration through gloves to the palm of the hand gives a misleading indication of the transmission of vibration to the fingers.

  12. Research on simultaneous impact of hand-arm and whole-body vibration.

    PubMed

    Kowalski, Piotr; Zając, Jacek

    2012-01-01

    This article presents the results of laboratory tests on the combined effect of whole-body vibration (WBV) and hand-arm vibration (HAV). The reactions of subjects exposed to various combinations of vibration were recorded. The vibrotactile perception threshold (VPT) test identified changes caused by exposure to vibration. Ten male subjects met the criteria of the study. There were 4 series of tests: a reference test and tests after exposure to HAV, WBV, and after simultaneous exposure to HAV and WBV. An analysis of the results (6000 ascending and descending VPTs) showed that the changes in VPTs were greatest after simultaneous exposure to both kinds of vibration. The increase in VPT, for all stimulus frequencies, was then higher than after exposure to HAV or WBV only.

  13. Interethnic differences at the thermometric response to cold test: functional disorders of blood circulation in hand fingers and exposure to hand-arm vibration.

    PubMed

    Riolfi, A; Princivalle, A; Romeo, L; Caramaschi, P; Perbellini, L

    2008-02-01

    To report some notable aspects regarding thermometric response to cold test in black African subjects compared with Caucasians: both groups comprised persons exposed to hand-arm vibration and controls. An overall sample of 48 workers was examined in order to study their blood circulation in hand fingers: a control group of 12 healthy Caucasian workers never exposed before to hand-arm vibration; 12 Caucasian workers exposed for several years to vibrating tools and affected by occupational Raynaud's phenomenon; 12 healthy black African workers exposed to hand-arm vibration for almost 3 years; and 12 healthy black African workers never exposed to hand-arm vibration. Computerized skin thermometry was performed and thermometric curves were analyzed according to thermometric interpretation criteria such as the area-over-curve (AOC), the fifth minute of recovery/baseline temperature ratio (5REC/BT) and the temperature at the tenth minute of recovery (10REC) after cold test. Thermometric parameters in Caucasian subjects confirmed the basis of the existing literature in controls (basal finger temperature higher than 32 degrees C and complete recovery to the initial temperature after the cold test) and also in patients with Raynaud's phenomenon (basal temperature often lower than control subjects and slow recovery of finger temperature after cold test). Statistically significant difference was found between healthy Caucasians and healthy black subjects in all the parameters tested: healthy black subjects showed values of AOC and 10REC suggesting almost constantly lower finger temperatures during the thermometry test. Black people, both exposed and non-exposed to hand-arm vibration showed thermometric parameters suggesting poor blood microcirculation, which seems even poorer than in Caucasian people complaining Raynaud's phenomenon. Our chronothermometric tests suggest some significant interethnic differences in peripheral microcirculation, which seems rather poor in black

  14. [Clinical features of the hand-arm vibration syndrome in miners].

    PubMed

    Kákosy, Tibor; Németh, László; Kiss, Gábor; Lászlóffy, Marianna; Kardos, Kálmán

    2006-05-07

    It is well known that the vibrating tools used by the miners can cause hand-arm vibration syndrome. However no detailed reports on this field could be found in the Hungarian literature. The aim of this study was to clarify the clinical features of the hand-arm vibration syndrome of the miners. The circulation, the peripheral nerves and the osteoarticular system of the upper extremities of 152 miners were examined by means of cold provocation test, Allen-test, measurement of systolic blood pressure performed by Doppler flowmeter, clinical neurological and neurographic examination and X-ray investigation of the bones and joints. Hand-arm vibration syndrome was diagnosed in 87 patients (57.2%). The most common symptom was the lesion of the circulation which occurred in 78 patients (89.6%). The peripheral nerves were affected in 44 cases (50.5%). Radiological alteration of the bones and joints of the upper extremities was observed in 32 patients (36.8%). Out of 78 damaged cases the frequency of the vascular diseases was as follows: angiopathy (diminished systolic blood pressure in the fingers): 66 patient (84.6%), occlusion of the hand arteries (positive Allen-test) and arterial form of the thoracic outlet syndrome (positive elevation-test) respectively: 28 and 28 cases (35.9%), Raynaud phenomenon (positive cold-provocation test): 26 cases (33.3%). The peripheral nerves were examined in detail in 141 cases. Pathological alterations were observed in 78 patients (55.3%) in the following forms: carpal tunnel syndrome: 66 cases (84.6%), peripheral neuropathy of the upper limbs: 20 patients (25.6%), lesion of the ulnar nerve: 3 cases (3.8%), brachial plexus lesion: one patient (1.3%). Radiological alteration was most common in the carpal region (87 cases, 57.2%). The frequency of the lesion of cubital (40.4%) and shoulder region (40.7%) was practically the same. In the carpal region the most common alterations were the degenerative processes (23 cases, 15.1%) followed by

  15. The Efficacy of Anti-vibration Gloves

    PubMed Central

    Hewitt, Sue; Dong, Ren; McDowell, Tom; Welcome, Daniel

    2016-01-01

    Anyone seeking to control the risks from vibration transmitted to the hands and arms may contemplate the use of anti-vibration gloves. To make an informed decision about any type of personal protective equipment, it is necessary to have performance data that allow the degree of protection to be estimated. The information provided with an anti-vibration glove may not be easy to understand without some background knowledge of how gloves are tested and does not provide any clear route for estimating likely protection. Some of the factors that influence the potential efficacy of an anti-vibration glove include how risks from hand–arm vibration exposure are assessed, how the standard test for a glove is carried out, the frequency range and direction of the vibration for which protection is sought, how much hand contact force or pressure is applied and the physical limitations due to glove material and construction. This paper reviews some of the background issues that are useful for potential purchasers of anti-vibration gloves. Ultimately, anti-vibration gloves cannot be relied on to provide sufficient and consistent protection to the wearer and before their use is contemplated all other available means of vibration control ought first to be implemented. PMID:27582615

  16. Hand-arm vibration syndrome from exposure to high-pressure hoses.

    PubMed

    Cooke, R; House, R; Lawson, I J; Pelmear, P L; Wills, M

    2001-09-01

    Hand-arm vibration syndrome has been reported in the literature to occur following exposure to vibration from the use of many tools, but to date there have been no case reports of its occurrence in workers who have used high-pressure hoses, alone or with other tools. To remedy this, the case histories of nine subjects (two without mixed exposure) examined in the UK and Canada are presented, together with their severity classified according to the Stockholm scales. Attention is drawn to the need to use multiple diagnostic tests to establish the diagnosis and the need to implement vibration isolation and damping methodologies, as and when feasible, with respect to hose nozzles in order to minimize the hazard. The ultimate goal for tool manufacturers, hygienists and engineers should be to reduce workplace vibration levels to meet national and international guidelines and legislation, including UK Health & Safety Executive guidelines and European Economic Community directives. The respective risk levels are presented, together with vibration measurements on hoses used by some of the cases.

  17. Muscular forearm activation in hand-grip tasks with superimposition of mechanical vibrations.

    PubMed

    Fattorini, L; Tirabasso, A; Lunghi, A; Di Giovanni, R; Sacco, F; Marchetti, E

    2016-02-01

    The purpose of this paper is to evaluate the muscular activation of the forearm, with or without vibration stimuli at different frequencies while performing a grip tasks of 45s at various level of exerted force. In 16 individuals, 9 females and 7 males, the surface electromyogram (EMG) of extensor carpi radialis longus and the flexor carpi ulnari muscles were assessed. At a short latency from onset EMG, RMS and the level of MU synchronization were assessed to evaluate the muscular adaptations. Whilst a trend of decay of EMG Median frequency (MDFd) was employed as an index of muscular fatigue. Muscular tasks consists of the grip of an instrumented handle at a force level of 20%, 30%, 40%, 60% of the maximum voluntary force. Vibration was supplied by a shaker to the hand in mono-frequential waves at 20, 30, 33 and 40Hz. In relation to EMG, RMS and MU synchronization, the muscular activation does not seem to change with the superimposition of the mechanical vibrations, on the contrary a lower MDFd was observed at 33Hz than in absence of vibration. This suggests an early muscular fatigue induced by vibration due to the fact that 33Hz is a resonance frequency for the hand-arm system. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Establishment of one-axis vibration test system for measurement of biodynamic response of human hand-arm system.

    PubMed

    Shibata, Nobuyuki; Hosoya, Naoki; Maeda, Setsuo

    2008-12-01

    Prolonged exposure to hand-arm vibration (HAV) due to use of hand-held power tools leads to an increased occurrence of symptoms of disorders in the vascular, neurological, and osteo-articular systems of the upper limbs called hand-arm vibration syndrome (HAVS). Biodynamic responses of the hand-arm system to vibration can be suggestive parameters that give us better assessment of exposure to HAV and fundamental data for design of low-vibration-exposure power tools. Recently, a single axis hand-arm vibration system has been installed in the Japan National Institute of Occupational Safety and Health (NIOSH). The aims of this study were to obtain the fundamental dynamic characteristics of an instrumented handle and to validate the performance and measurement accuracy of the system applied to dynamic response measurement. A pseudo-random vibration signal with a frequency range of 5-1,250 Hz and a power spectrum density of 1.0 (m/s2)2/Hz was used in this study. First the dynamic response of the instrumented handle without any weight was measured. After this measurement, the dynamic response measurement of the handle with weights mounted on the handle was performed. The apparent mass of a weight itself was obtained by using the mass cancellation method. The mass of the measuring cap on the instrumented handle was well compensated by using the mass cancellation method. Based on the 10% error tolerance, this handle can reliably measure the dynamic response represented by an apparent mass with a minimum weight of 2.0 g in a frequency range of 10.0 to 1,000 Hz. A marked increase in the AM magnitude of the weights of 15 g and 20 g in frequency ranges greater than 800 Hz is attributed not to the fundamental resonance frequency of the handle with weights, but to the fixation of the weight to the measuring cap. In this aspect, the peak of the AM magnitude can be reduced and hence should not be an obstacle to the biodynamic response measurement of the human hand-arm system. On the

  19. Change of a motor synergy for dampening hand vibration depending on a task difficulty.

    PubMed

    Togo, Shunta; Kagawa, Takahiro; Uno, Yoji

    2014-10-01

    The present study investigated the relationship between the number of usable degrees of freedom (DOFs) and joint coordination during a human-dampening hand vibration task. Participants stood on a platform generating an anterior-posterior directional oscillation and held a water-filled cup. Their usable DOFs were changed under the following conditions of limb constraint: (1) no constraint; (2) ankle constrained; and (3) ankle-knee constrained. Kinematic whole-body data were recorded using a three-dimensional position measurement system. The jerk of each body part was evaluated as an index of oscillation intensity. To quantify joint coordination, an uncontrolled manifold (UCM) analysis was applied and the variance of joints related to hand jerk divided into two components: a UCM component that did not affect hand jerk and an orthogonal (ORT) component that directly affected hand jerk. The results showed that hand jerk when the task used a cup filled with water was significantly smaller than when a cup containing stones was used, regardless of limb constraint condition. Thus, participants dampened their hand vibration utilizing usable joint DOFs. According to UCM analysis, increasing the oscillation velocity and the decrease in usable DOFs by the limb constraints led to an increase of total variance of the joints and the UCM component, indicating that a synergy-dampening hand vibration was enhanced. These results show that the variance of usable joint DOFs is more fitted to the UCM subspace when the joints are varied by increasing the velocity and limb constraints and suggest that humans adopt enhanced synergies to achieve more difficult tasks.

  20. A longitudinal study of vibration white finger, cold response of digital arteries, and measures of daily vibration exposure.

    PubMed

    Bovenzi, Massimo

    2010-03-01

    To investigate prospectively the relation between vibration-induced vascular disorders and measures of daily exposure to hand-transmitted vibration (HTV). Two hundred and forty-nine HTV workers and 138 control men of the same companies participated in a 3-year follow-up study. The diagnosis of vibration induced white finger (VWF) in the HTV workers and that of Raynaud's phenomenon in the controls was based on the medical history, the administration of color charts and the results of a cold test with measurement of finger systolic blood pressures. Vibration magnitudes from the tools were measured as r.m.s acceleration, frequency weighted according to international standard ISO 5349-1, and also unweighted over the frequency range 6.3-1,250 Hz. Daily vibration exposure was expressed in terms of daily exposure duration and frequency-weighted or unweighted r.m.s. acceleration normalized to a reference period of 8 h (Aw(8) or Auw(8), respectively). The incidence of VWF varied from 5 to 6% in the HTV workers versus 0-1.5% for Raynaud's phenomenon in the controls. After adjusting for potential confounders, Auw(8) gave better predictions of the incidence of VWF and the cold response of the digital arteries over time than Aw(8) or daily exposure duration. These findings were observed in the entire sample of HTV workers, in those with no VWF at the initial investigation, and in those with normal cold test results at baseline. The findings of this longitudinal study suggest that a measure of daily vibration exposure calculated from unweighted r.m.s. acceleration over the frequency range 6.3-1,250 Hz performs better for the prediction of vascular disorders in users of vibratory tools than a measure derived from r.m.s. acceleration frequency weighted according to ISO 5349-1. This study provides epidemiological evidence that more weight should be given to intermediate and high-frequency vibration for evaluating the severity of hand-transmitted vibration.

  1. Review and Evaluation of Hand-Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces.

    PubMed

    Dong, Ren G; Sinsel, Erik W; Welcome, Daniel E; Warren, Christopher; Xu, Xueyan S; McDowell, Thomas W; Wu, John Z

    2015-09-01

    The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study.

  2. Hand-arm vibration syndrome: clinical characteristics, conventional electrophysiology and quantitative sensory testing.

    PubMed

    Rolke, Roman; Rolke, Silke; Vogt, Thomas; Birklein, Frank; Geber, Christian; Treede, Rolf-Detlef; Letzel, Stephan; Voelter-Mahlknecht, Susanne

    2013-08-01

    Workers exposed to vibrating tools may develop hand-arm vibration syndrome (HAVS). We assessed the somatosensory phenotype using quantitative sensory testing (QST) in comparison to electrophysiology to characterize (1) the most sensitive QST parameter for detecting sensory loss, (2) the correlation of QST and electrophysiology, and (3) the frequency of a carpal tunnel syndrome (CTS) in HAVS. QST, cold provocation tests, fine motor skills, and median nerve neurography were used. QST included thermal and mechanical detection and pain thresholds. Thirty-two patients were examined (54 ± 11 years, 91% men) at the more affected hand compared to 16 matched controls. Vibration detection threshold was the most sensitive parameter to detect sensory loss that was more pronounced in the sensitivity range of Pacinian (150 Hz, x12) than Meissner's corpuscles (20 Hz, x3). QST (84% abnormal) was more sensitive to detect neural dysfunction than conventional electrophysiology (37% abnormal). Motor (34%) and sensory neurography (25%) were abnormal in HAVS. CTS frequency was not increased (9.4%). Findings are consistent with a mechanically-induced, distally pronounced motor and sensory neuropathy independent of CTS. HAVS involves a neuropathy predominantly affecting large fibers with a sensory damage related to resonance frequencies of vibrating tools. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Nailfold capillary morphological characteristics of hand-arm vibration syndrome: a cross-sectional study

    PubMed Central

    Chen, QingSong; Chen, GuiPing; Xiao, Bin; Lin, HanSheng; Qu, HongYing; Zhang, DanYing; Shi, MaoGong; Lang, Li; Yang, Bei; Yan, MaoSheng

    2016-01-01

    Objective The purpose of this study was to investigate the characteristics of nailfold capillaroscopy associated with hand-arm vibration syndrome (HAVS). Methods In total, 113 male gold miners were recruited: 35 workers who were chronically exposed to vibration and developed vibration-induced white finger were defined as the HAVS group, 39 workers who were exposed to vibration but did not have HAVS were classified as the vibration-exposed controls (VEC) group, and 39 workers without vibration exposure were categorised as the non-VEC (NVEC) group. Video capillaroscopy was used to capture images of the 2nd, 3rd and 4th fingers of both hands. The following nailfold capillary characteristics were included: number of capillaries/mm, avascular areas, haemorrhages and enlarged capillaries. The experiments were carried out in the same winter. All characteristics were evaluated under blinded conditions. Results Significant differences in all morphological characteristics existed between the groups (p<0.05). Avascular areas in the HAVS, VEC and NVEC groups appeared in 74.3%, 43.6% and 25.0% of participants, respectively. A higher percentage of participants had haemorrhages in the HAVS group (65.7%) compared with the other groups (VEC: 7.7% and NVEC: 7.5%). The number of capillaries/mm, input limb width, output limb width, apical width, and ratio of output limb and input limb all had more than 70% sensitivity or specificity of their cut-off value. Conclusions Nailfold capillary characteristics, especially the number of capillaries/mm, avascular areas, haemorrhages, output limb width, input limb width and apical width alterations, revealed significant associations with HAVS. PMID:27888176

  4. Biodynamic response at the palm of the human hand subjected to a random vibration.

    PubMed

    Dong, Ren G; McDowell, Thomas W; Welcome, Daniel E

    2005-01-01

    This study investigated the biodynamic response (BR) distributed at the palm of the hand subjected to a random vibration. Twelve male subjects were used in the experiment. Each subject applied three coupling actions (grip-only, push-only, and combined grip and push) on a simulated tool handle at three different levels (50, 75, and 100 N) of palm force. This study found that the hand-arm system resonated mostly in the frequency range of 20 to 50 Hz, depending on the specific test treatment and individual characteristics. The maximum vibration power transmission through the palm occurred at the resonant frequency. Increasing the effective palm force generally increased the BR magnitude and resonant frequency. The apparent stiffness measured at the middle frequencies (80-100 Hz) is correlated to the BR in almost the entire frequency range (20-1,000 Hz). Under the same palm force, the push-only action corresponded to the highest BR values while the grip-only action generally produced the lowest values. Since the resonant frequency range matches the dominant vibration frequency range of many percussive tools, it is anticipated that the palm BR and vibration power transmission may have an association with vibration-induced injuries or disorders in the wrist-arm system among the workers using these tools.

  5. Laboratory and Workplace Assessments of Rivet Bucking Bar Vibration Emissions

    PubMed Central

    McDowell, Thomas W.; Warren, Christopher; Xu, Xueyan S.; Welcome, Daniel E.; Dong, Ren G.

    2016-01-01

    Sheet metal workers operating rivet bucking bars are at risk of developing hand and wrist musculoskeletal disorders associated with exposures to hand-transmitted vibrations and forceful exertions required to operate these hand tools. New bucking bar technologies have been introduced in efforts to reduce workplace vibration exposures to these workers. However, the efficacy of these new bucking bar designs has not been well documented. While there are standardized laboratory-based methodologies for assessing the vibration emissions of many types of powered hand tools, no such standard exists for rivet bucking bars. Therefore, this study included the development of a laboratory-based method for assessing bucking bar vibrations which utilizes a simulated riveting task. With this method, this study evaluated three traditional steel bucking bars, three similarly shaped tungsten alloy bars, and three bars featuring spring-dampeners. For comparison the bucking bar vibrations were also assessed during three typical riveting tasks at a large aircraft maintenance facility. The bucking bars were rank-ordered in terms of unweighted and frequency-weighted acceleration measured at the hand-tool interface. The results suggest that the developed laboratory method is a reasonable technique for ranking bucking bar vibration emissions; the lab-based riveting simulations produced similar rankings to the workplace rankings. However, the laboratory-based acceleration averages were considerably lower than the workplace measurements. These observations suggest that the laboratory test results are acceptable for comparing and screening bucking bars, but the laboratory measurements should not be directly used for assessing the risk of workplace bucking bar vibration exposures. The newer bucking bar technologies exhibited significantly reduced vibrations compared to the traditional steel bars. The results of this study, together with other information such as rivet quality, productivity, tool

  6. Vibration induced white-feet: overview and field study of vibration exposure and reported symptoms in workers.

    PubMed

    Eger, Tammy; Thompson, Aaron; Leduc, Mallorie; Krajnak, Kristine; Goggins, Katie; Godwin, Alison; House, Ron

    2014-01-01

    Workers who stand on platforms or equipment that vibrate are exposed to foot-transmitted vibration (FTV). Exposure to FTV can lead to vibration white feet/toes resulting in blanching of the toes, and tingling and numbness in the feet and toes. The objectives are 1) to review the current state of knowledge of the health risks associated with foot-transmitted vibration (FTV), and 2) to identify the characteristics of FTV and discuss the associated risk of vibration-induced injury. Workers who operated locomotives (n=3), bolting platforms (n=10), jumbo drills (n=7), raise drilling platforms (n=4), and crushers (n=3), participated. A tri-axial accelerometer was used to measure FTV in accordance with ISO 2631-1 guidelines. Frequency-weighted root-mean-square acceleration and the dominant frequency are reported. Participants were also asked to report pain/ache/discomfort in the hands and/or feet. Reports of pain/discomfort/ache were highest in raise platform workers and jumbo drill operators who were exposed to FTV in the 40 Hz and 28 Hz range respectively. Reports of discomfort/ache/pain were lowest in the locomotive and crusher operators who were exposed to FTV below 10 Hz. These findings are consistent with animal studies that have shown vascular and neural damage in exposed appendages occurs at frequencies above 40 Hz. Operators exposed to FTV at 40 Hz appear to be at greater risk of experiencing vibration induced injury. Future research is required to document the characteristics of FTV and epidemiological evidence is required to link exposure with injury.

  7. Aesthesiometric threshold changes over the course of a workshift in miners exposed to hand-arm vibration.

    PubMed Central

    Haines, T; Chong, J; Verrall, A B; Julian, J; Bernholz, C; Spears, R; Muir, D C

    1988-01-01

    The objective of this study was to investigate whether aesthesiometric threshold changes occur over the course of a workshift in vibration exposed hard rock miners relative to workers unexposed to vibration during the shift. The subjects were 99 miners and 40 smelter workers; four subjects declined to participate and nine were excluded from the analysis because of apparent failure to comprehend the testing procedure. Two point discrimination and depth sense aesthesiometry were conducted at the beginning and at the end of the workshift in all digits of both hands excluding the thumbs. In addition to the use of a vibrating tool during the shift, age, digital temperature, signs of arm injury, presence of fingertip callus, and handedness were documented. In the analysis the difference between postshift and preshift readings was studied in relation to these variables, particularly exposure to the jackleg drill during the shift. With the exception of exposure of the jackleg drill, no associations were observed between these variables and change over the workshift in aesthesiometric results, on both unadjusted comparison of means and backward elimination regression analysis. A statistically significant association, however, was found between the use of a jackleg drill and change in two point discrimination and in depth sense aesthesiometric results over the course of the shift, for the right hand. Evidence of the occurrence of a learning effect, particularly for two point discrimination aesthesiometry, was observed. The occurrence of an effect in the right, but not the left, hand reflects dominant handedness and relatively greater vibration exposure in the right hand in our subjects. This study supports the incorporation of an exposure free interval before aesthesiometric testing of vibration exposed workers. PMID:3342191

  8. Power tiller: vibration magnitudes and intervention development for vibration reduction.

    PubMed

    Chaturvedi, Varun; Kumar, Adarsh; Singh, J K

    2012-09-01

    The operators of power tiller are exposed to a high level of vibration originating from the dynamic interaction between the soil and the machine. The vibration from the power tiller is transmitted from the handle to hands, arms and shoulders. In the present study, experiments were conducted in three operational conditions i.e. transportation on farm roads, tilling with cultivator and rota-tilling with rota-vator. The highest vibration values were observed in x-direction in all the experiments. The maximum vibration rms values for x-direction were 5.96, 6.81 and 8.00 ms(-2) in tilling with cultivator, transportation and rota-tilling respectively. Three materials were used for intervention development to reduce vibration magnitude. The maximum reduction of 25.30, 31.21 and 30.45% in transportation; 23.50, 30.64 and 20.86% in tilling with cultivator and 24.03, 29.18 and 25.52% in rota-tilling were achieved with polyurethane (PU), rubber and combination of PU and rubber intervention. It was found that the maximum vibration reductions were achieved with the rubber in all three operational conditions. The average exposure time for occurrence of white finger syndrome increased by 28-50% with incorporation of intervention in different operations. Physiological and postural parameters also improved with incorporation of interventions. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  9. Short daily exposure to hand-arm vibrations in Swedish car mechanics.

    PubMed

    Barregård, Lars

    2003-01-01

    The aim of the study was to examine the daily exposure times to hand-arm vibrations in Swedish car mechanics, to test a method for estimating the exposure time without observing the workers for whole days, and to use the results for predicting the prevalence of vibration-induced white fingers (VWF) by the ISO 5349-model. Six garages were surveyed. In each garage, 5-10 car mechanics were observed in random order every 30 seconds throughout working days. The daily exposure time for each mechanic was estimated from the fraction of the observations that the mechanic was exposed. A total of 51 mechanics were observed, most of them on two different working days, yielding estimates for 95 days. The median effective exposure time was 10 minutes per day (95% confidence interval 5-15 minutes, arithmetic mean 14 minutes, maximum 80 minutes), and most of the exposure time was attributable to fastening and loosening nuts. The within-worker and between-worker variability was high (total sigma2 0.99, geometric standard deviation of 2.7). Using the observed exposure time and data on vibration levels of the main tools in Swedish car mechanics (average weighted acceleration level of 3.5 m/s2), the model in ISO-standard 5349 would predict that only three percent of the car mechanics will suffer from VWF after 20 years of exposure. In contrast, a recent survey of VWF showed the prevalence to be 25 percent. The precision of the observation method was estimated and was found to be good for the group daily mean. On the individual level the precision was only acceptable if the daily exposure time was > or = 40 minutes. In conclusion, the daily exposure time was short and the vibration level was limited. Nevertheless, hand-arm vibrations cause VWF in a significant number of car mechanics. The method of observing workers intermittently seemed to work well.

  10. Recent advances in biodynamics of human hand-arm system.

    PubMed

    Dong, Ren G; Wu, John Z; Welcome, Daniel E

    2005-07-01

    The biodynamics of human hand-arm system is one of the most important foundations for the measurement, evaluation, and risk assessment of hand-transmitted vibration (HTV) exposure. This paper presents a new conceptual model relating factors influencing cause-effect relationships for HTV exposure, a new study strategy, and a comprehensive review of the recent advances in the biodynamics closely associated with HTV exposure. The review covers the following five aspects: theoretical modeling of biodynamic responses, vibration transmissibility, driving-point biodynamic responses, evaluation of anti-vibration gloves, and applied forces. This review finds that some significant advances in each of these aspects have been achieved in the recent years. Several important issues and problems in the biodynamic measurement have been identified and resolved, which has significantly helped improve the reliability and accuracy of the experimental data. The results reported in recent years suggest that, from the point of view of biodynamics, the frequency weighting specified in ISO 5349-1 (2001) overestimates the low frequency effect but underestimates the high frequency effect on the fingers and hand. The major problems, issues, and topics for further studies are also outlined in this paper. It is anticipated that the further studies of the biodynamics of the system will eventually lead to establishment of a robust vibration exposure theory. Although this review focuses on the biodynamics of the hand-arm system, the fundamental concepts and some methodologies reviewed in this paper may also be applicable for the study of whole-body vibration exposure.

  11. A prospective cohort study investigating an exposure-response relationship among vibration-exposed male workers with numbness of the hands.

    PubMed

    Edlund, Maria; Burström, Lage; Gerhardsson, Lars; Lundström, Ronnie; Nilsson, Tohr; Sandén, Helena; Hagberg, Mats

    2014-03-01

    The aim of this study was to investigate the exposure-response relationship of hand-arm vibration exposure to neurological symptoms (numbness) of the hand in a cohort of vibration-exposed workers. The baseline cohort comprised 241 office and manual workers with and without exposure to hand-arm vibration. Numbness (the symptom or event) in the hand was assessed for all subjects at baseline and follow-ups after 5, 10, and 16 years. The workers were stratified into quartiles with no exposure in the first quartile and increasing intensity of exposure in quartiles 2-4 (groups 1-3). Data analysis was performed using survival analysis (time to event). Information on cumulative exposure and years of exposure to event was collected via questionnaires. Measurements were performed in accordance with the International Organization for Standardization (ISO) 5349-1. The hazard ratio (HR) of risk of event (numbness) differed statistically significantly between the non-exposed group (group 0) and the two higher exposure groups (groups 2 and 3). There was also a significant ratio difference between the lowest exposure group (group 1) and the two higher groups. The ratio for group 1 was 1.77 [95% confidence interval (95% CI) 0.96-3.26] compared with 3.78 (95% CI 2.15-6.62) and 5.31 (95% CI 3.06-9.20) for groups 2 and 3, respectively. The results suggest a dose-response relationship between vibration exposure and numbness of the hands. This underlines the importance of keeping vibration levels low to prevent neurological injury to the hands.

  12. Variability in hand-arm vibration during grinding operations.

    PubMed

    Liljelind, Ingrid; Wahlström, Jens; Nilsson, Leif; Toomingas, Allan; Burström, Lage

    2011-04-01

    Measurements of exposure to vibrations from hand-held tools are often conducted on a single occasion. However, repeated measurements may be crucial for estimating the actual dose with good precision. In addition, knowledge of determinants of exposure could be used to improve working conditions. The aim of this study was to assess hand-arm vibration (HAV) exposure during different grinding operations, in order to obtain estimates of the variance components and to evaluate the effect of work postures. Ten experienced operators used two compressed air-driven angle grinders of the same make in a simulated work task at a workplace. One part of the study consisted of using a grinder while assuming two different working postures: at a standard work bench (low) and on a wall with arms elevated and the work area adjusted to each operator's height (high). The workers repeated the task three times. In another part of the study, investigating the wheel wear, for each grinder, the operators used two new grinding wheels and with each wheel the operator performed two consecutive 1-min grinding tasks. Both grinding tasks were conducted on weld puddles of mild steel on a piece of mild steel. Measurements were taken according to ISO-standard 5349 [the equivalent hand-arm-weighted acceleration (m s(-2)) averaged over 1 min]. Mixed- and random-effects models were used to investigate the influence of the fixed variables and to estimate variance components. The equivalent hand-arm-weighted acceleration assessed when the task was performed on the bench and at the wall was 3.2 and 3.3 m s(-2), respectively. In the mixed-effects model, work posture was not a significant variable. The variables 'operator' and 'grinder' together explained only 12% of the exposure variability and 'grinding wheel' explained 47%; the residual variability of 41% remained unexplained. When the effect of grinding wheel wear was investigated in the random-effects model, 37% of the variability was associated with

  13. Nailfold capillary morphological characteristics of hand-arm vibration syndrome: a cross-sectional study.

    PubMed

    Chen, QingSong; Chen, GuiPing; Xiao, Bin; Lin, HanSheng; Qu, HongYing; Zhang, DanYing; Shi, MaoGong; Lang, Li; Yang, Bei; Yan, MaoSheng

    2016-11-25

    The purpose of this study was to investigate the characteristics of nailfold capillaroscopy associated with hand-arm vibration syndrome (HAVS). In total, 113 male gold miners were recruited: 35 workers who were chronically exposed to vibration and developed vibration-induced white finger were defined as the HAVS group, 39 workers who were exposed to vibration but did not have HAVS were classified as the vibration-exposed controls (VEC) group, and 39 workers without vibration exposure were categorised as the non-VEC (NVEC) group. Video capillaroscopy was used to capture images of the 2nd, 3rd and 4th fingers of both hands. The following nailfold capillary characteristics were included: number of capillaries/mm, avascular areas, haemorrhages and enlarged capillaries. The experiments were carried out in the same winter. All characteristics were evaluated under blinded conditions. Significant differences in all morphological characteristics existed between the groups (p<0.05). Avascular areas in the HAVS, VEC and NVEC groups appeared in 74.3%, 43.6% and 25.0% of participants, respectively. A higher percentage of participants had haemorrhages in the HAVS group (65.7%) compared with the other groups (VEC: 7.7% and NVEC: 7.5%). The number of capillaries/mm, input limb width, output limb width, apical width, and ratio of output limb and input limb all had more than 70% sensitivity or specificity of their cut-off value. Nailfold capillary characteristics, especially the number of capillaries/mm, avascular areas, haemorrhages, output limb width, input limb width and apical width alterations, revealed significant associations with HAVS. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  14. [Clinical efficacy of mouse nerve growth factor in treatment of occupational hand-arm vibration disease].

    PubMed

    Fan, Chunyue; Wang, Yanyan; Zhang, Ying; Lang, Li; Deng, Xiaofeng; Cheng, Ying

    2014-12-01

    To investigate the efficacy of mouse nerve growth factor (mNGF) in treating occupational hand-arm vibration disease (HAVD). Sixty-four patients with HAVD were equally and randomly divided into treatment group and control group. The control group was given Salvia miltiorrhiza Bunge and deproteinized extract of calf blood to improve circulation, and also given methylcobalamin tablets and vitamin B6 for neurotrophic treatment. In addition to the above treatments for the control group, the treatment group was also given 30 µg/d mNGF by intramuscular injection for two courses (4 weeks for each course) with a 15-day interval. Both the treatment group and the control group showed significant improvements in clinical symptoms and signs (hand numbness and pain, and reduced senses of touch, pain, and vibration), cold water loading test (CWLT), and electroneuromyography (ENMG) after treatments (P < 0.05). And the treatment group had significantly more improvements than the control group (P < 0.05). mNGF can significantly improve hand numbness and pain, reduced senses of touch, pain, and vibration, CWLT, and ENMG, so it has better clinical effect and safety in treating HAVD. Early diagnosis and treatment can improve the outcome of patients with HAVD.

  15. Quantitatively measured tremor in hand-arm vibration-exposed workers.

    PubMed

    Edlund, Maria; Burström, Lage; Hagberg, Mats; Lundström, Ronnie; Nilsson, Tohr; Sandén, Helena; Wastensson, Gunilla

    2015-04-01

    The aim of the present study was to investigate the possible increase in hand tremor in relation to hand-arm vibration (HAV) exposure in a cohort of exposed and unexposed workers. Participants were 178 male workers with or without exposure to HAV. The study is cross-sectional regarding the outcome of tremor and has a longitudinal design with respect to exposure. The dose of HAV exposure was collected via questionnaires and measurements at several follow-ups. The CATSYS Tremor Pen(®) was used for measuring postural tremor. Multiple linear regression methods were used to analyze associations between different tremor variables and HAV exposure, along with predictor variables with biological relevance. There were no statistically significant associations between the different tremor variables and cumulative HAV or current exposure. Age was a statistically significant predictor of variation in tremor outcomes for three of the four tremor variables, whereas nicotine use was a statistically significant predictor of either left or right hand or both hands for all four tremor variables. In the present study, there was no evidence of an exposure-response association between HAV exposure and measured postural tremor. Increase in age and nicotine use appeared to be the strongest predictors of tremor.

  16. Vibration induced white-feet: Overview and field study of vibration exposure and reported symptoms in workers

    PubMed Central

    Eger, Tammy; Thompson, Aaron; Leduc, Mallorie; Krajnak, Kristine; Goggins, Katie; Godwin, Alison; House, Ron

    2015-01-01

    BACKGROUND Workers who stand on platforms or equipment that vibrate are exposed to foot-transmitted vibration (FTV). Exposure to FTV can lead to vibration white feet/toes resulting in blanching of the toes, and tingling and numbness in the feet and toes. OBJECTIVES The objectives are 1) to review the current state of knowledge of the health risks associated with foot-transmitted vibration (FTV), and 2) to identify the characteristics of FTV and discuss the associated risk of vibration-induced injury. PARTICIPANTS Workers who operated locomotives (n = 3), bolting platforms (n = 10), jumbo drills (n = 7), raise drilling platforms (n = 4), and crushers (n = 3), participated. METHODS A tri-axial accelerometer was used to measure FTV in accordance with ISO 2631-1 guidelines. Frequency-weighted root-mean-square acceleration and the dominant frequency are reported. Participants were also asked to report pain/ache/discomfort in the hands and/or feet. RESULTS Reports of pain/discomfort/ache were highest in raise platform workers and jumbo drill operators who were exposed to FTV in the 40 Hz and 28 Hz range respectively. Reports of discomfort/ache/pain were lowest in the locomotive and crusher operators who were exposed to FTV below 10 Hz. These findings are consistent with animal studies that have shown vascular and neural damage in exposed appendages occurs at frequencies above 40 Hz. CONCLUSIONS Operators exposed to FTV at 40 Hz appear to be at greater risk of experiencing vibration induced injury. Future research is required to document the characteristics of FTV and epidemiological evidence is required to link exposure with injury. PMID:24004754

  17. Laboratory and workplace assessments of rivet bucking bar vibration emissions.

    PubMed

    McDowell, Thomas W; Warren, Christopher; Xu, Xueyan S; Welcome, Daniel E; Dong, Ren G

    2015-04-01

    Sheet metal workers operating rivet bucking bars are at risk of developing hand and wrist musculoskeletal disorders associated with exposures to hand-transmitted vibrations and forceful exertions required to operate these hand tools. New bucking bar technologies have been introduced in efforts to reduce workplace vibration exposures to these workers. However, the efficacy of these new bucking bar designs has not been well documented. While there are standardized laboratory-based methodologies for assessing the vibration emissions of many types of powered hand tools, no such standard exists for rivet bucking bars. Therefore, this study included the development of a laboratory-based method for assessing bucking bar vibrations which utilizes a simulated riveting task. With this method, this study evaluated three traditional steel bucking bars, three similarly shaped tungsten alloy bars, and three bars featuring spring-dampeners. For comparison the bucking bar vibrations were also assessed during three typical riveting tasks at a large aircraft maintenance facility. The bucking bars were rank-ordered in terms of unweighted and frequency-weighted acceleration measured at the hand-tool interface. The results suggest that the developed laboratory method is a reasonable technique for ranking bucking bar vibration emissions; the lab-based riveting simulations produced similar rankings to the workplace rankings. However, the laboratory-based acceleration averages were considerably lower than the workplace measurements. These observations suggest that the laboratory test results are acceptable for comparing and screening bucking bars, but the laboratory measurements should not be directly used for assessing the risk of workplace bucking bar vibration exposures. The newer bucking bar technologies exhibited significantly reduced vibrations compared to the traditional steel bars. The results of this study, together with other information such as rivet quality, productivity, tool

  18. System transmits mechanical vibration into hazardous environment

    NASA Technical Reports Server (NTRS)

    Armstrong, D. G.; Gaal, A. E.

    1965-01-01

    Vibration transducers are tested in a hazardous environment using a single axis transmission system with an electromagnetic shaker table and vibrating wires which drive identical rocker arms, one in the test cell and the other outside. This system can be modified for a multiaxis configuration.

  19. Normative data for neuromuscular assessment of the hand-arm vibration syndrome and its retrospective applications in Korean male workers.

    PubMed

    Ahn, Ryeok; Yoo, Cheol-In; Lee, Hun; Sim, Chang-Sun; Sung, Joo Hyun; Yoon, Jae-Kook; Shin, Song-Woo

    2013-10-01

    The purpose of this study was to describe normative data for the neuromuscular assessments of the hand-arm vibration syndrome (HAVS) in Korean. Data for the vibrotactile perception threshold (VPT) at three frequencies (31.5, 125, and 250 Hz), the hand grip strength (HGS), the finger pinch strength (FPS), the finger tapping test, and the Purdue pegboard tests were collected from 120 male office workers aged 30-59 years with no prior history of regular use of handheld vibrating tools. The collected data were compared with the results of a similar study of shipbuilding workers in order to investigate the diagnostic utility of clinical test for HAVS. The mean VPT values indicate that no significant differences were observed between the dominant and non-dominant hands or between the index and little fingers. The age group of 30s was highly sensitive to vibration input with a peak in sensitivity at 125 Hz among all age groups. In neuromuscular performance, dominant hands are usually more accurate, dexterous, and functionally quicker than non-dominant hands. The index finger was superior to the little finger in the finger tapping counts (p < 0.05). Also, FPS was greater in the index finger than in the middle finger (p < 0.05). The HGS of dominant hands was significantly stronger than that of non-dominant hands (p < 0.05). When the normative data were compared with the data of shipyard workers exposed to vibration, there were statistically significant differences in VPT and neuromuscular functions. The current data can be used to evaluate HAVS in Korean male workers. Age is an important factor for VPT.

  20. Mechanical impedance and absorbed power of hand-arm under x(h)-axis vibration and role of hand forces and posture.

    PubMed

    Aldien, Yasser; Marcotte, Pierre; Rakheja, Subhash; Boileau, Paul-Emile

    2005-07-01

    The biodynamic responses of the hand-arm system under x(h)-axis vibration are investigated in terms of the driving point mechanical impedance (DPMI) and absorbed power in a laboratory study. For this purpose, seven healthy male subjects are exposed to two levels of random vibration in the 8-1,000 Hz frequency range, using three instrumented cylindrical handles of different diameters (30, 40 and 50 mm), and different combinations of grip (10, 30 and 50 N) and push (0, 25 and 50 N) forces. The experiments involve grasping the handle while adopting two different postures, involving elbow flexion of 90 degrees and 180 degrees, with wrist in the neutral position for both postures. The analyses of the results revealed peak DPMI magnitude and absorbed power responses near 25 Hz and 150 Hz, for majority of the test conditions considered. The frequency corresponding to the peak response increased with increasing hand forces. Unlike the absorbed power, the DPMI response was mostly observed to be insensitive to variations in the excitation magnitude. The handle diameter revealed obvious effects on the DPMI magnitude, specifically at frequencies above 250 Hz, which was not evident in the absorbed power due to relatively low velocity at higher frequencies. The influence of hand forces was also evident on the DPMI magnitude response particularly at frequencies. above 100 Hz, while the effect of hand-arm posture on the DPMI magnitude was nearly negligible. The magnitude of power absorbed within the hand and arm was observed to be strongly dependent upon the excitation level over the entire frequency range, while the influence of hand-arm posture on the total absorbed power was observed to be important. The effect of variations in the hand forces on the absorbed power was relatively small for the bent elbow posture, while an increase in either the grip or the push force coupled with the extended arm posture resulted in considerably higher energy absorption. The results suggested

  1. Characterization of Frequency-Dependent Responses of the Vascular System to Repetitive Vibration

    PubMed Central

    Krajnak, Kristine; Miller, G. Roger; Waugh, Stacey; Johnson, Claud; Kashon, Michael L.

    2015-01-01

    Objective Occupational exposure to hand-transmitted vibration can result in damage to nerves and sensory loss. The goal of this study was to assess the frequency-dependent effects of repeated bouts of vibration on sensory nerve function and associated changes in nerves. Methods The tails of rats were exposed to vibration at 62.5, 125, or 250 Hz (constant acceleration of 49m/s2) for 10 days. The effects on sensory nerve function, nerve morphology, and transcript expression in ventral tail nerves were measured. Results Vibration at all frequencies had effects on nerve function and physiology. However, the effects tended to be more prominent with exposure at 250 Hz. Conclusion Exposure to vibration has detrimental effects on sensory nerve function and physiology. However, many of these changes are more prominent at 250-Hz exposure than at lower frequencies. PMID:22785326

  2. Development of vibration isolation platform for low amplitude vibration

    NASA Astrophysics Data System (ADS)

    Lee, Dae-Oen; Park, Geeyong; Han, Jae-Hung

    2014-03-01

    The performance of high precision payloads on board a satellite is extremely sensitive to vibration. Although vibration environment of a satellite on orbit is very gentle compared to the launch environment, even a low amplitude vibration disturbances generated by reaction wheel assembly, cryocoolers, etc may cause serious problems in performing tasks such as capturing high resolution images. The most commonly taken approach to protect sensitive payloads from performance degrading vibration is application of vibration isolator. In this paper, development of vibration isolation platform for low amplitude vibration is discussed. Firstly, single axis vibration isolator is developed by adapting three parameter model using bellows and viscous fluid. The isolation performance of the developed single axis isolator is evaluated by measuring force transmissibility. The measured transmissibility shows that both the low Q-factor (about 2) and the high roll-off rate (about -40 dB/dec) are achieved with the developed isolator. Then, six single axis isolators are combined to form Stewart platform in cubic configuration to provide multi-axis vibration isolation. The isolation performance of the developed multi-axis isolator is evaluated using a simple prototype reaction wheel model in which wheel imbalance is the major source of vibration. The transmitted force without vibration isolator is measured and compared with the transmitted force with vibration isolator. More than 20 dB reduction of the X and Y direction (radial direction of flywheel) disturbance is observed for rotating wheel speed of 100 Hz and higher.

  3. Current Perception Threshold for Assessment of the Neurological Components of Hand-Arm Vibration Syndrome: A Review

    PubMed Central

    Kurozawa, Youichi; Hosoda, Takenobu; Nasu, Yoshiro

    2010-01-01

    Current perception threshold (CPT) has been proposed as a quantitative method for assessment of peripheral sensory nerve function. The aim of this review of selected reports is to provide an overview of CPT measurement for the assessment of the neurological component of hand-arm vibration syndrome (HAVS). The CPT values at 2000 Hz significantly increased for patients with HAVS. This result supports the previous histological findings that demyelination is found predominantly in the peripheral nerves in the hands of men exposed to hand-arm vibration. Diagnostic sensitivity and specificity were high for severe cases of Stockholm sensorineural (SSN) stage 3 compared with non-exposed controls, but not high for mild cases of SSN stage 1 or 2 and for carpal tunnel syndrome associated with HAVS. However, there are only a few studies on the diagnostic validity of the CPT test for the neurological components of HAVS. Further research is needed and should include diagnostic validity and standardizing of measurement conditions such as skin temperature. PMID:24031119

  4. Work disability after diagnosis of hand-arm vibration syndrome.

    PubMed

    Sauni, Riitta; Toivio, Pauliina; Pääkkönen, Rauno; Malmström, Jari; Uitti, Jukka

    2015-11-01

    Our aim was to study the course of vasospastic and sensorineural symptoms after the clinical diagnosis of hand-arm vibration syndrome (HAVS), and the association of current HAVS symptoms with occupational status, self-evaluation of health, quality of life, and work ability. We gathered all HAVS cases diagnosed at the Finnish Institute of Occupational Health in Helsinki and Tampere during 1990-2008. A questionnaire was sent to all these patients (n = 241). Altogether 149 of them (62 %) returned the questionnaire. Cumulative lifelong vibration exposure was evaluated on the basis of the data in the patient files. On average, 8.5 years after the diagnosis of HAVS, approximately one-third of the patients reported improvement in symptoms of vibration-induced white finger (VWF) and the sensorineural symptoms. Young age and shorter exposure time were associated with improvement in VWF symptoms (p = 0.033 and p < 0.001, respectively). Persistent or deteriorated symptoms of both VWF and sensorineural symptoms were associated with lowered work ability, quality of life (EQ-5D), and general health, also after adjusting for age, smoking, and diseases other than HAVS. The patients' own prediction of work ability in 2 years was more negative if the VWF symptoms or sensorineural symptoms had continued after diagnosis of HAVS (p = 0.065 and p = 0.001, respectively). Our results suggest that in about two-thirds of the patients, the HAVS symptoms may stabilize or deteriorate in the follow-up. Considering the effects on work ability, timely prevention measures should be taken more actively to help patients continue their working careers.

  5. Decentralized semi-active damping of free structural vibrations by means of structural nodes with an on/off ability to transmit moments

    NASA Astrophysics Data System (ADS)

    Poplawski, Blazej; Mikułowski, Grzegorz; Mróz, Arkadiusz; Jankowski, Łukasz

    2018-02-01

    This paper proposes, tests numerically and verifies experimentally a decentralized control algorithm with local feedback for semi-active mitigation of free vibrations in frame structures. The algorithm aims at transferring the vibration energy of low-order, lightly-damped structural modes into high-frequency modes of vibration, where it is quickly damped by natural mechanisms of material damping. Such an approach to mitigation of vibrations, known as the prestress-accumulation release (PAR) strategy, has been earlier applied only in global control schemes to the fundamental vibration mode of a cantilever beam. In contrast, the decentralization and local feedback allows the approach proposed here to be applied to more complex frame structures and vibration patterns, where the global control ceases to be intuitively obvious. The actuators (truss-frame nodes with controllable ability to transmit moments) are essentially unblockable hinges that become unblocked only for very short time periods in order to trigger local modal transfer of energy. The paper proposes a computationally simple model of the controllable nodes, specifies the control performance measure, yields basic characteristics of the optimum control, proposes the control algorithm and then tests it in numerical and experimental examples.

  6. A prospective cohort study of exposure-response relationship for vibration-induced white finger.

    PubMed

    Bovenzi, M

    2010-01-01

    To investigate prospectively the relation between vibration-induced white finger (VWF) and measures of cumulative (lifetime) exposure to hand-transmitted vibration (HTV). Two hundred and forty-nine HTV workers and 138 control men of the same companies participated in a 3-year follow-up study. The diagnosis of VWF (Raynaud's phenomenon in the controls) was based on the medical history, the administration of colour charts and the results of a cold test. Tool vibration magnitudes were expressed as root-mean-square (r.m.s.) acceleration, frequency-weighted according to international standard ISO 5349-1 and also unweighted over the frequency range 6.3-1250 Hz. From the vibration magnitudes and exposure durations, alternative measures of cumulative vibration dose were calculated for each HTV worker, according to the expression: dose = Sigmaa(i)(m)t(i), where a(i) is the acceleration magnitude on tool i, t(i) is the lifetime exposure duration (hours) for tool i, and m = 0, 1, 2 or 4. The incidence of VWF varied from 5 to 6% in the HTV workers versus 0 to 1.5% for Raynaud's phenomenon in the controls. After adjusting for potential confounders, measures of cumulative vibration dose derived from total operating hours and high powers of unweighted acceleration (ie, , with m>1) gave better predictions of the occurrence of VWF than dose measures calculated from frequency-weighted acceleration (ie, ). These findings were observed in the entire sample of HTV workers, in those with no VWF at the initial investigation, and in those with normal cold test results at baseline. This prospective cohort study suggests that measures of cumulative vibration doses constructed from unweighted r.m.s. acceleration perform better for the prediction of VWF than dose measures calculated according to the recommendations of current standards. These findings should contribute to the improvement of the ISO frequency weighting for evaluating the severity of hand-transmitted vibration.

  7. Study of vibrations produced by a vibrating beam used for vibrating concretes. [and their transmission to human operator

    NASA Technical Reports Server (NTRS)

    Silas, C.; Brindeu, L.; Grosanu, I.; Cioara, T.

    1974-01-01

    For compacting concretes in building, vibrating beams are used. The vibrations are generated by inertial vibrators, and the beam is normally displaced by the operator by means of a handle that is elastically fastened to the beam by means of rubber pads. Considered are vibrations transmitted to the operator, taking into account the beam's shock vibration motions. The steady state motion of a dynamic beam pattern is studied, and results of experimental tests with existing equipment are presented.

  8. Contact area affects frequency-dependent responses to vibration in the peripheral vascular and sensorineural systems.

    PubMed

    Krajnak, Kristine; Miller, G R; Waugh, Stacey

    2018-01-01

    Repetitive exposure to hand-transmitted vibration is associated with development of peripheral vascular and sensorineural dysfunctions. These disorders and symptoms associated with it are referred to as hand-arm vibration syndrome (HAVS). Although the symptoms of the disorder have been well characterized, the etiology and contribution of various exposure factors to development of the dysfunctions are not well understood. Previous studies performed using a rat-tail model of vibration demonstrated that vascular and peripheral nervous system adverse effects of vibration are frequency-dependent, with vibration frequencies at or near the resonant frequency producing the most severe injury. However, in these investigations, the amplitude of the exposed tissue was greater than amplitude typically noted in human fingers. To determine how contact with vibrating source and amplitude of the biodynamic response of the tissue affects the risk of injury occurring, this study compared the influence of frequency using different levels of restraint to assess how maintaining contact of the tail with vibrating source affects the transmission of vibration. Data demonstrated that for the most part, increasing the contact of the tail with the platform by restraining it with additional straps resulted in an enhancement in transmission of vibration signal and elevation in factors associated with vascular and peripheral nerve injury. In addition, there were also frequency-dependent effects, with exposure at 250 Hz generating greater effects than vibration at 62.5 Hz. These observations are consistent with studies in humans demonstrating that greater contact and exposure to frequencies near the resonant frequency pose the highest risk for generating peripheral vascular and sensorineural dysfunction.

  9. Vibrating fuel grapple

    DOEpatents

    Chertock, deceased, Alan J.; Fox, Jack N.; Weissinger, Robert B.

    1982-01-01

    A reactor refueling method utilizing a vibrating fuel grapple for removing spent fuel assemblies from a reactor core which incorporates a pneumatic vibrator in the grapple head, enabling additional withdrawal capability without exceeding the allowable axial force limit. The only moving part in the vibrator is a steel ball, pneumatically driven by a gas, such as argon, around a track, with centrifugal force created by the ball being transmitted through the grapple to the assembly handling socket.

  10. Vibration syndrome in railway track maintenance workers.

    PubMed

    Virokannas, H; Anttonen, H; Niskanen, J

    1995-01-01

    An inquiry was sent to all railway maintenance workers in three railway districts in Finland and hand-arm vibration was measured on the handlebars of tools used by maintenance workers. The study group included 252 (82%) subjects, whose mean age was 41 years and who had worked in track maintenance for 14 years (SD 9). In Finland there are over 600 railway maintenance workers who use vibrating tools. The frequency-weighted acceleration of hand-arm vibration was calculated according to the ISO 5349 standard. Hand-held tamping machines had caused most of the vibration exposure, and aw4h was 10.6 m/s2 measured on the handlebar of tamping machine, but many workers also used other vibrating tools. The annual vibration level was 2.5 m/s2 when the use of all vibrating tools and the exposure time was taken into account. In the questionnaire the prevalence of vibration-induced white finger (VWF) was 14% in the entire material, and the prevalence of VWF increased significantly with the total duration of the maintenance work. In addition, 39% of the subjects had suffered numbness of the hands, and the prevalence of hand numbness also increased significantly with the total duration of maintenance work. According to the measurements of vibration and the prevalence of hand symptoms the present investigation indicates vibration syndrome as being related to railway track maintenance work. In the exposure group, where tamping machines mainly were used and exposure to other vibration was small, the prevalence of VWF was also significantly higher, but the prevalence of hand numbness insignificant compared with the control group. In this study vascular and nerve hand symptoms were considered to cause serious trouble in work by 4-11% of the maintenance workers.

  11. Perceptual Space of Superimposed Dual-Frequency Vibrations in the Hands.

    PubMed

    Hwang, Inwook; Seo, Jeongil; Choi, Seungmoon

    2017-01-01

    The use of distinguishable complex vibrations that have multiple spectral components can improve the transfer of information by vibrotactile interfaces. We investigated the qualitative characteristics of dual-frequency vibrations as the simplest complex vibrations compared to single-frequency vibrations. Two psychophysical experiments were conducted to elucidate the perceptual characteristics of these vibrations by measuring the perceptual distances among single-frequency and dual-frequency vibrations. The perceptual distances of dual-frequency vibrations between their two frequency components along their relative intensity ratio were measured in Experiment I. The estimated perceptual spaces for three frequency conditions showed non-linear perceptual differences between the dual-frequency and single-frequency vibrations. A perceptual space was estimated from the measured perceptual distances among ten dual-frequency compositions and five single-frequency vibrations in Experiment II. The effect of the component frequency and the frequency ratio was revealed in the perceptual space. In a percept of dual-frequency vibration, the lower frequency component showed a dominant effect. Additionally, the perceptual difference among single-frequency and dual-frequency vibrations were increased with a low relative difference between two frequencies of a dual-frequency vibration. These results are expected to provide a fundamental understanding about the perception of complex vibrations to enrich the transfer of information using vibrotactile stimuli.

  12. Force illusions and drifts observed during muscle vibration.

    PubMed

    Reschechtko, Sasha; Cuadra, Cristian; Latash, Mark L

    2018-01-01

    We explored predictions of a scheme that views position and force perception as a result of measuring proprioceptive signals within a reference frame set by ongoing efferent process. In particular, this hypothesis predicts force illusions caused by muscle vibration and mediated via changes in both afferent and efferent components of kinesthesia. Healthy subjects performed accurate steady force production tasks by pressing with the four fingers of one hand (the task hand) on individual force sensors with and without visual feedback. At various times during the trials, subjects matched the perceived force using the other hand. High-frequency vibration was applied to one or both of the forearms (over the hand and finger extensors). Without visual feedback, subjects showed a drop in the task hand force, which was significantly smaller under the vibration of that forearm. Force production by the matching hand was consistently higher than that of the task hand. Vibrating one of the forearms affected the matching hand in a manner consistent with the perception of higher magnitude of force produced by the vibrated hand. The findings were consistent between the dominant and nondominant hands. The effects of vibration on both force drift and force mismatching suggest that vibration led to shifts in both signals from proprioceptors and the efferent component of perception, the referent coordinate and/or coactivation command. The observations fit the hypothesis on combined perception of kinematic-kinetic variables with little specificity of different groups of peripheral receptors that all contribute to perception of forces and coordinates. NEW & NOTEWORTHY We show that vibration of hand/finger extensors produces consistent errors in finger force perception. Without visual feedback, finger force drifted to lower values without a drift in the matching force produced by the other hand; hand extensor vibration led to smaller finger force drift. The findings fit the scheme with

  13. Assessment of thermotactile and vibrotactile thresholds for detecting sensorineural components of the hand-arm vibration syndrome (HAVS).

    PubMed

    Ye, Ying; Griffin, Michael J

    2018-01-01

    Thermotactile thresholds and vibrotactile thresholds are measured to assist the diagnosis of the sensorineural component of the hand-arm vibration syndrome (HAVS). This study investigates whether thermotactile and vibrotactile thresholds distinguish between fingers with and without numbness and tingling. In 60 males reporting symptoms of the hand-arm vibration syndrome, thermotactile thresholds for detecting hot and cold temperatures and vibrotactile thresholds at 31.5 and 125 Hz were measured on the index and little fingers of both hands. In fingers reported to suffer numbness or tingling, hot thresholds increased, cold thresholds decreased, and vibrotactile thresholds at both 31.5 and 125 Hz increased. With sensorineural symptoms on all three phalanges (i.e. numbness or tingling scores of 6), both thermotactile thresholds and both vibrotactile thresholds had sensitivities greater than 80% and specificities around 90%, with areas under the receiver operating characteristic curves around 0.9. There were correlations between all four thresholds, but cold thresholds had greater sensitivity and greater specificity on fingers with numbness or tingling on only the distal phalanx (i.e. numbness or tingling scores of 1) suggesting cold thresholds provide better indications of early sensorineural disorder. Thermotactile thresholds and vibrotactile thresholds can provide useful indications of sensorineural function in patients reporting symptoms of the sensorineural component of HAVS.

  14. Review and Evaluation of Hand–Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces

    PubMed Central

    Dong, Ren G.; Sinsel, Erik W.; Welcome, Daniel E.; Warren, Christopher; Xu, Xueyan S.; McDowell, Thomas W.; Wu, John Z.

    2015-01-01

    The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study. PMID:26929824

  15. Work ability in vibration-exposed workers.

    PubMed

    Gerhardsson, L; Hagberg, M

    2014-12-01

    Hand-arm vibration exposure may cause hand-arm vibration syndrome (HAVS) including sensorineural disturbances. To investigate which factors had the strongest impact on work ability in vibration-exposed workers. A cross-sectional study in which vibration-exposed workers referred to a department of occupational and environmental medicine were compared with a randomized sample of unexposed subjects from the general population of the city of Gothenburg. All participants underwent a structured interview, answered several questionnaires and had a physical examination including measurements of hand and finger muscle strength and vibrotactile and thermal perception thresholds. The vibration-exposed group (47 subjects) showed significantly reduced sensitivity to cold and warmth in digit 2 bilaterally (P < 0.01) and in digit 5 in the left hand (P < 0.05) and to warmth in digit 5 in the right hand (P < 0.01), compared with the 18 referents. Similarly, tactilometry showed significantly raised vibration perception thresholds among the workers (P < 0.05). A strong relationship was found for the following multiple regression model: estimated work ability = 11.4 - 0.1 × age - 2.3 × current stress level - 2.5 × current pain in hands/arms (multiple r = 0.68; P < 0.001). Vibration-exposed workers showed raised vibrotactile and thermal perception thresholds, compared with unexposed referents. Multiple regression analysis indicated that stress disorders and muscle pain in hands/arms must also be considered when evaluating work ability among subjects with HAVS. © The Author 2014. Published by Oxford University Press on behalf of the Society of Occupational Medicine.

  16. A systematic review of the etiopathogenesis of Kienböck's disease and a critical appraisal of its recognition as an occupational disease related to hand-arm vibration

    PubMed Central

    2012-01-01

    Background We systematically reviewed etiological factors of Kienböck’s disease (osteonecrosis of the lunate) discussed in the literature in order to examine the justification for including Kienböck’s disease (KD) in the European Listing of Occupational Diseases. Methods We searched the Ovid/Medline and the Cochrane Library for articles discussing the etiology of osteonecrosis of the lunate published since the first description of KD in 1910 and up until July 2012 in English, French or German. Literature was classified by the level of evidence presented, the etiopathological hypothesis discussed, and the author's conclusion about the role of the etiopathological hypothesis. The causal relationship between KD and hand-arm vibration was elucidated by the Bradford Hill criteria. Results A total of 220 references was found. Of the included 152 articles, 140 (92%) reached the evidence level IV (case series). The four most frequently discussed factors were negative ulnar variance (n=72; 47%), primary arterial ischemia of the lunate (n=63; 41%), trauma (n=63; 41%) and hand-arm vibration (n=53; 35%). The quality of the cohort studies on hand-arm vibration did not permit a meta-analysis to evaluate the strength of an association to KD. Evidence for the lack of consistency, plausibility and coherence of the 4 most frequently discussed etiopathologies was found. No evidence was found to support any of the nine Bradford Hill criteria for a causal relationship between KD and hand-arm vibration. Conclusions A systematic review of 220 articles on the etiopathology of KD and the application of the Bradford Hill criteria does not provide sufficient scientific evidence to confirm or refute a causal relationship between KD and hand-arm vibration. This currently suggests that, KD does not comply with the criteria of the International Labour Organization determining occupational diseases. However, research with a higher level of evidence is required to further determine if hand

  17. A systematic review of the etiopathogenesis of Kienböck's disease and a critical appraisal of its recognition as an occupational disease related to hand-arm vibration.

    PubMed

    Stahl, Stéphane; Stahl, Adelana Santos; Meisner, Christoph; Rahmanian-Schwarz, Afshin; Schaller, Hans-Eberhard; Lotter, Oliver

    2012-11-21

    We systematically reviewed etiological factors of Kienböck's disease (osteonecrosis of the lunate) discussed in the literature in order to examine the justification for including Kienböck's disease (KD) in the European Listing of Occupational Diseases. We searched the Ovid/Medline and the Cochrane Library for articles discussing the etiology of osteonecrosis of the lunate published since the first description of KD in 1910 and up until July 2012 in English, French or German. Literature was classified by the level of evidence presented, the etiopathological hypothesis discussed, and the author's conclusion about the role of the etiopathological hypothesis. The causal relationship between KD and hand-arm vibration was elucidated by the Bradford Hill criteria. A total of 220 references was found. Of the included 152 articles, 140 (92%) reached the evidence level IV (case series). The four most frequently discussed factors were negative ulnar variance (n=72; 47%), primary arterial ischemia of the lunate (n=63; 41%), trauma (n=63; 41%) and hand-arm vibration (n=53; 35%). The quality of the cohort studies on hand-arm vibration did not permit a meta-analysis to evaluate the strength of an association to KD. Evidence for the lack of consistency, plausibility and coherence of the 4 most frequently discussed etiopathologies was found. No evidence was found to support any of the nine Bradford Hill criteria for a causal relationship between KD and hand-arm vibration. A systematic review of 220 articles on the etiopathology of KD and the application of the Bradford Hill criteria does not provide sufficient scientific evidence to confirm or refute a causal relationship between KD and hand-arm vibration. This currently suggests that, KD does not comply with the criteria of the International Labour Organization determining occupational diseases. However, research with a higher level of evidence is required to further determine if hand-arm vibration is a risk factor for KD.

  18. Diagnostic criteria and staging of hand-arm vibration syndrome in the United Kingdom.

    PubMed

    McGeoch, Kenneth L; Lawson, Ian J; Burke, Frank; Proud, George; Miles, Jeremy

    2005-07-01

    In the United Kingdom the diagnosis of Hand-arm Vibration Syndrome varies depending on the purpose of that diagnosis. The criteria differ in three situations. More than 100,000 miners and ex-miners with claims for HAVS have been examined using a Medical Assessment Process which included the use of standardised tests. This contract is unique but it has had significant effects on the two other processes. The Industrial Injuries Disablement Benefit Scheme provides a benefit that can be paid to an employed earner because of an accident or Prescribed Disease. New recommendations have been published to remove the anomalies in the present format for assessing HAVS. If implemented the new scheme will recognise the Stockholm Workshop Scales and workers with neurological problems will also be compensated. The Health and Safety Executive will issue new guidance in the near future on the hazards of hand-arm vibration. Health surveillance in the workplace will be fundamental and the HSE propose a tiered approach with levels 1 to 5. Specialist occupational nurses and doctors with training in the diagnosis and assessment of HAVS will be needed for levels 3 and 4. Only at this level may a diagnosis of HAVS be made. The Medical Assessment Process has demonstrated that it is possible to examine a large number of claimants in a standardised manner. The IIAC and HSE recommendations contain very important improvements on the existing positions in the UK and it must be hoped that they will be implemented in the near future.

  19. Reductions in finger blood flow induced by 125-Hz vibration: effect of location of contact with vibration.

    PubMed

    Ye, Ying; Griffin, Michael J

    2016-04-01

    This study investigated whether the reductions in finger blood flow induced by 125-Hz vibration applied to different locations on the hand depend on thresholds for perceiving vibration at these locations. Subjects attended three sessions during which vibration was applied to the right index finger, the right thenar eminence, or the left thenar eminence. Absolute thresholds for perceiving vibration at these locations were determined. Finger blood flow in the middle finger of both hands was then measured at 30-s intervals during five successive 5-min periods: (i) pre-exposure, (ii) pre-exposure with 2-N force, (iii) 2-N force with vibration, (iv) post-exposure with 2-N force, (v) recovery. During period (iii), vibration was applied at 15 dB above the absolute threshold for perceiving vibration at the right thenar eminence. Vibration at all three locations reduced finger blood flow on the exposed and unexposed hand, with greater reductions when vibrating the finger. Vibration-induced vasoconstriction was greatest for individuals with low thresholds and locations of excitation with low thresholds. Differences in vasoconstriction between subjects and between locations are consistent with the Pacinian channel mediating both absolute thresholds and vibration-induced vasoconstriction.

  20. An interpretative phenomenological analysis of the psychological ramifications of hand-arm vibration syndrome.

    PubMed

    Ayers, Beverley; Forshaw, Mark

    2010-05-01

    With a substantial number of individuals diagnosed with Hand-Arm Vibration Syndrome (HAVS) and the preponderance of research focused on the medical and paramedical issues, the psychological and mental health sequelae of HAVS are largely neglected within the published literature. A series of focus groups and interviews were conducted involving nine people who had been diagnosed with HAVS. Transcripts of these interviews were analysed using Interpretative Phenomenological Analysis. Four key themes were identified within the discourse of individuals affected by HAVS: machismo; coping; psychological impacts; and the development of support services for HAVS. Clinical implications are briefly discussed.

  1. Vibrating fuel grapple. [LMFBR

    DOEpatents

    Chertock, A.J.; Fox, J.N.; Weissinger, R.B.

    A reactor refueling method is described which utilizes a vibrating fuel grapple for removing spent fuel assemblies from a reactor core. It incorporates a pneumatic vibrator in the grapple head which allows additional withdrawal capability without exceeding the allowable axial force limit. The only moving part in the vibrator is a steel ball, pneumatically driven by a gas, such as argon, around a track, with centrifugal force created by the ball being transmitted through the grapple to the assembly handling socket.

  2. Compact Active Vibration Control System for a Flexible Panel

    NASA Technical Reports Server (NTRS)

    Schiller, Noah H. (Inventor); Cabell, Randolph H. (Inventor); Perey, Daniel F. (Inventor)

    2014-01-01

    A diamond-shaped actuator for a flexible panel has an inter-digitated electrode (IDE) and a piezoelectric wafer portion positioned therebetween. The IDE and/or the wafer portion are diamond-shaped. Point sensors are positioned with respect to the actuator and measure vibration. The actuator generates and transmits a cancelling force to the panel in response to an output signal from a controller, which is calculated using a signal describing the vibration. A method for controlling vibration in a flexible panel includes connecting a diamond-shaped actuator to the flexible panel, and then connecting a point sensor to each actuator. Vibration is measured via the point sensor. The controller calculates a proportional output voltage signal from the measured vibration, and transmits the output signal to the actuator to substantially cancel the vibration in proximity to each actuator.

  3. Relationship between self-reported upper limb disability and quantitative tests in hand-arm vibration syndrome.

    PubMed

    Poole, Kerry; Mason, Howard

    2007-03-15

    To establish the relationship between quantitative tests of hand function and upper limb disability, as measured by the Disability of the Arm, Shoulder and Hand (DASH) questionnaire, in hand-arm vibration syndrome (HAVS). A total of 228 individuals with HAVS were included in this study. Each had undergone a full HAVS assessment by an experienced physician, including quantitative tests of vibrotactile and thermal perception thresholds, maximal hand-grip strength (HG) and the Purdue pegboard (PP) test. Individuals were also asked to complete a DASH questionnaire. PP and HG of the quantitative tests gave the best and statistically significant individual correlations with the DASH disability score (r2 = 0.168 and 0.096). Stepwise linear regression analysis revealed that only PP and HG measurements were statistically significant predictors of upper limb disability (r2 = 0.178). Overall a combination of the PP and HG measurements, rather than each alone, gave slightly better discrimination, although not statistically significant, between normal and abnormal DASH scores with a sensitivity of 73.1% and specificity of 64.3%. Measurements of manual dexterity and hand-grip strength using PP and HG may be useful in helping to confirm lack of upper limb function and 'perceived' disability in HAVS.

  4. Associations of work activities requiring pinch or hand grip or exposure to hand-arm vibration with finger and wrist osteoarthritis: a meta-analysis.

    PubMed

    Hammer, Paula E C; Shiri, Rahman; Kryger, Ann I; Kirkeskov, Lilli; Bonde, Jens Peter

    2014-03-01

    We systematically reviewed the epidemiologic evidence linking finger and wrist osteoarthritis (OA) with work activities requiring pinch or hand grip or exposure to hand-arm vibration (HAV). PubMed and Embase databases were searched up to June 2013. We selected studies assessing the associations of radiographic diagnosed finger and/or wrist joint OA with work activities involving pinch or hand grip or exposure to HAV. We used specific criteria to evaluate completeness of reporting, potential confounding, and bias. Pooled odds ratios (OR) were computed using random-effects meta-analyses. Of the 19 studies included, 17 were cross-sectional, 1 was a prospective cohort, and 1 a case-control study. The meta-analyses of studies that controlled their estimates for at least age and gender showed the associations of pinch grip work with proximal interphalangeal joint [OR 1.56, 95% confidence interval (95% CI) 1.09-2.23] and the first carpometacarpal joint OA (OR 2.10, 95% CI 1.06-4.17), but not with distal interphalangeal, metacarpalphalangeal, or wrist joints OA. Hand grip work and exposure to HAV were not associated with any finger or wrist OA. Epidemiological studies provide limited evidence that pinch grip may increase the risk of wrist or finger OA, but causal relation cannot be resolved because of cross-sectional designs and inadequate characterization of biomechanical strain to the hand and wrist.

  5. Delivery of health surveillance for hand-arm vibration in the West Midlands.

    PubMed

    Kinoulty, Mary

    2006-01-01

    Concerns about provider competence and quality of hand-arm vibrations (HAVs) health surveillance programmes were identified by Health & Safety Executive (HSE) inspectors. To evaluate health surveillance programmes and compare them with published HSE guidance. To identify deficiencies and areas for improvement in the health surveillance programmes. A proforma was developed for the study and used on a sample of 10 local occupational health providers. All 10 organizations were aware of current HSE guidance for health surveillance for HAVs but only a minority (30%) were following it. Occupational health provider training, written procedures and health surveillance delivery were all identified as areas requiring improvement. The majority of organizations were not following HSE guidance. Occupational health providers undertaking health surveillance for HAV require specific training.

  6. Transcriptional Pathways Altered in Response to Vibration in a Model of Hand-Arm Vibration Syndrome.

    PubMed

    Waugh, Stacey; Kashon, Michael L; Li, Shengqiao; Miller, Gerome R; Johnson, Claud; Krajnak, Kristine

    2016-04-01

    The aim of this study was to use an established model of vibration-induced injury to assess frequency-dependent changes in transcript expression in skin, artery, and nerve tissues. Transcript expression in tissues from control and vibration-exposed rats (4 h/day for 10 days at 62.5, 125, or 250 Hz; 49 m/s, rms) was measured. Transcripts affected by vibration were used in bioinformatics analyses to identify molecular- and disease-related pathways associated with exposure to vibration. Analyses revealed that cancer-related pathways showed frequency-dependent changes in activation or inhibition. Most notably, the breast-related cancer-1 pathway was affected. Other pathways associated with breast cancer type 1 susceptibility protein related signaling, or associated with cancer and cell cycle/cell survivability were also affected. Occupational exposure to vibration may result in DNA damage and alterations in cell signaling pathways that have significant effects on cellular division.

  7. Transcriptional Pathways Altered in Response to Vibration in a Model of Hand-Arm Vibration Syndrome

    PubMed Central

    Waugh, Stacey; Kashon, Michael L.; Li, Shengqiao; Miller, Gerome R.; Johnson, Claud; Krajnak, Kristine

    2016-01-01

    Objective The aim of this study was to use an established model of vibration-induced injury to assess frequency-dependent changes in transcript expression in skin, artery, and nerve tissues. Methods Transcript expression in tissues from control and vibration-exposed rats (4 h/day for 10 days at 62.5, 125, or 250 Hz; 49 m/s2, rms) was measured. Transcripts affected by vibration were used in bioinformatics analyses to identify molecular- and disease-related pathways associated with exposure to vibration. Results Analyses revealed that cancer-related pathways showed frequency-dependent changes in activation or inhibition. Most notably, the breast-related cancer-1 pathway was affected. Other pathways associated with breast cancer type 1 susceptibility protein related signaling, or associated with cancer and cell cycle/cell survivability were also affected. Conclusion Occupational exposure to vibration may result in DNA damage and alterations in cell signaling pathways that have significant effects on cellular division. PMID:27058473

  8. Materials Testing in Long Cane Design: Sensitivity, Flexibility, and Transmission of Vibration

    ERIC Educational Resources Information Center

    Rodgers, Mark D.; Emerson, Robert Wall

    2005-01-01

    Different materials that are used in manufacturing long cane shafts were assessed for their ability to transmit vibration and their sensitivity to tactile information, flexibility, and durability. It was found that the less flexible a cane shaft is, the better it transmits vibrations that are useful for discriminating surface textures and that…

  9. Vocal Dose Measures: Quantifying Accumulated Vibration Exposure in Vocal Fold Tissues

    PubMed Central

    Titze, Ingo R.; Švec, Jan G.; Popolo, Peter S.

    2011-01-01

    To measure the exposure to self-induced tissue vibration in speech, three vocal doses were defined and described: distance dose, which accumulates the distance that tissue particles of the vocal folds travel in an oscillatory trajectory; energy dissipation dose, which accumulates the total amount of heat dissipated over a unit volume of vocal fold tissues; and time dose, which accumulates the total phonation time. These doses were compared to a previously used vocal dose measure, the vocal loading index, which accumulates the number of vibration cycles of the vocal folds. Empirical rules for viscosity and vocal fold deformation were used to calculate all the doses from the fundamental frequency (F0) and sound pressure level (SPL) values of speech. Six participants were asked to read in normal, monotone, and exaggerated speech and the doses associated with these vocalizations were calculated. The results showed that large F0 and SPL variations in speech affected the dose measures, suggesting that accumulation of phonation time alone is insufficient. The vibration exposure of the vocal folds in normal speech was related to the industrial limits for hand-transmitted vibration, in which the safe distance dose was derived to be about 500 m. This limit was found rather low for vocalization; it was related to a comparable time dose of about 17 min of continuous vocalization, or about 35 min of continuous reading with normal breathing and unvoiced segments. The voicing pauses in normal speech and dialogue effectively prolong the safe time dose. The derived safety limits for vocalization will likely require refinement based on a more detailed knowledge of the differences in hand and vocal fold tissue morphology and their response to vibrational stress, and on the effect of recovery of the vocal fold tissue during voicing pauses. PMID:12959470

  10. Vocal dose measures: quantifying accumulated vibration exposure in vocal fold tissues.

    PubMed

    Titze, Ingo R; Svec, Jan G; Popolo, Peter S

    2003-08-01

    To measure the exposure to self-induced tissue vibration in speech, three vocal doses were defined and described: distance dose, which accumulates the distance that tissue particles of the vocal folds travel in an oscillatory trajectory; energy dissipation dose, which accumulates the total amount of heat dissipated over a unit volume of vocal fold tissues; and time dose, which accumulates the total phonation time. These doses were compared to a previously used vocal dose measure, the vocal loading index, which accumulates the number of vibration cycles of the vocal folds. Empirical rules for viscosity and vocal fold deformation were used to calculate all the doses from the fundamental frequency (F0) and sound pressure level (SPL) values of speech. Six participants were asked to read in normal, monotone, and exaggerated speech and the doses associated with these vocalizations were calculated. The results showed that large F0 and SPL variations in speech affected the dose measures, suggesting that accumulation of phonation time alone is insufficient. The vibration exposure of the vocal folds in normal speech was related to the industrial limits for hand-transmitted vibration, in which the safe distance dose was derived to be about 500 m. This limit was found rather low for vocalization; it was related to a comparable time dose of about 17 min of continuous vocalization, or about 35 min of continuous reading with normal breathing and unvoiced segments. The voicing pauses in normal speech and dialogue effectively prolong the safe time dose. The derived safety limits for vocalization will likely require refinement based on a more detailed knowledge of the differences in hand and vocal fold tissue morphology and their response to vibrational stress, and on the effect of recovery of the vocal fold tissue during voicing pauses.

  11. Illusory movements induced by tendon vibration in right- and left-handed people.

    PubMed

    Tidoni, Emmanuele; Fusco, Gabriele; Leonardis, Daniele; Frisoli, Antonio; Bergamasco, Massimo; Aglioti, Salvatore Maria

    2015-02-01

    Frequency-specific vibratory stimulation of peripheral tendons induces an illusion of limb movement that may be useful for restoring proprioceptive information in people with sensorimotor disability. This potential application may be limited by inter- and intra-subject variability in the susceptibility to such an illusion, which may depend on a variety of factors. To explore the influence of stimulation parameters and participants' handedness on the movement illusion, we vibrated the right and left tendon of the biceps brachii in a group of right- and left-handed people with five stimulation frequencies (from 40 to 120 Hz in step of 20 Hz). We found that all participants reported the expected illusion of elbow extension, especially after 40 and 60 Hz. Left-handers exhibited less variability in reporting the illusion compared to right-handers across the different stimulation frequencies. Moreover, the stimulation of the non-dominant arm elicited a more vivid illusion with faster onset relative to the stimulation of the dominant arm, an effect that was independent from participants' handedness. Overall, our data show that stimulation frequency, handedness and arm dominance influence the tendon vibration movement illusion. The results are discussed in reference to their relevance in linking motor awareness, improving current devices for motor ability recovery after brain or spinal damage and developing prosthetics and virtual embodiment systems.

  12. Multiple direction vibration fixture

    DOEpatents

    Cericola, Fred; Doggett, James W.; Ernest, Terry L.; Priddy, Tommy G.

    1991-01-01

    An apparatus for simulating a rocket launch environment on a test item undergoing centrifuge testing by subjecting the item simultaneously or separately to vibration along an axis of centripetal force and along an axis perpendicular to the centripetal force axis. The apparatus includes a shaker motor supported by centrifuge arms and a right angle fixture pivotally connected to one of the shaker motor mounts. When the shaker motor vibrates along the centripetal force axis, the vibrations are imparted to a first side of the right angle fixture. The vibrations are transmitted 90 degrees around the pivot and are directed to a second side of the right angle fixture which imparts vibrations perpendicular to the centripetal force axis. The test item is in contact with a third side of the right angle fixture and receives both centripetal-force-axis vibrations and perpendicular axis vibrations simultaneously. A test item can be attached to the third side near the flexible coupling or near the air bag to obtain vibrations along the centripetal force axis or transverse to the centripetal force axis.

  13. Vibration Analysis and the Accelerometer

    ERIC Educational Resources Information Center

    Hammer, Paul

    2011-01-01

    Have you ever put your hand on an electric motor or motor-driven electric appliance and felt it vibrate? Ever wonder why it vibrates? What is there about the operation of the motor, or the object to which it is attached, that causes the vibrations? Is there anything "regular" about the vibrations, or are they the result of random causes? In this…

  14. Whole body vibration in mountain-rescue operations

    NASA Astrophysics Data System (ADS)

    Alberti, E.; Chiappa, D.; Moschioni, G.; Saggin, B.; Tarabini, M.

    2006-12-01

    In mountain-rescue operations injured people are generally exposed to vibrations and shocks that can be potential causes of physical conditions worsening. Such vibrations can derive both from patient's body manipulations (e.g. when it is being loaded and immobilized on a stretcher) and from forces coming from the transport devices and vehicles. Despite the general feeling that during this kind of operations the levels of transmitted vibrations to the injured can be quite large and potentially dangerous, there is practically no study in literature providing reliable parameters (i.e. measurements) to support or dismiss these beliefs. This paper reports the results of a measurement campaign carried-out in order to outline, identify and quantify the excitations a human body is exposed to, during typical transportation phases related to mountain-rescue operations. The work mainly presents and discusses the experimental setup with the aim of focusing on the problems related to this kind of measurements; the results of the experimental campaign carried-out for the measurement of the vibrations undergone by a human body during a simulated rescue operation are presented and discussed as well. Such simulation includes three phases of transportation: on a hand-held stretcher, on an ambulance and on a helicopter. The work is not intended to supply a complete characterization and analysis of vibrations transmission during any rescue operation but just to provide a preliminary overview and to define a measurement method that can be applied for a more comprehensive characterization. With such aims measurements were carried out in on-field situations stated as "typical" by rescue experts and data then analyzed both with standard procedures and algorithms (e.g. ISO 2631s weighting curves) and with the commonly used statistical indexes; in the analysis it is important to be aware that standardized measurement procedures and indexes, created to verify comfort or health-risks of

  15. Vibration exercise makes your muscles and bones stronger: fact or fiction?

    PubMed

    Cardinale, Marco; Rittweger, Jörn

    2006-03-01

    Vibration transmitted to the whole body or part of it has been extensively studied in relation to the risks to the health and safety of workers. These studies have highlighted the particular danger of lower-back morbidity and spinal trauma arising after prolonged exposure to vibration. However, short-term exposure to whole-body vibration (WBV) or the use of vibrating dumbbells can have beneficial effects on the musculoskeletal system. As a consequence of this encouraging work, many manufacturers have developed exercise devices characterized by vibrating plates transmitting vibration to the whole body and vibrating dumbbells. Preliminary results seem to recommend WBV exercise as a therapeutic alternative for preventing/reversing sarcopenia and possibly osteoporosis. However, there is a paucity of well designed studies in the elderly. In particular, there is a lack of understanding of the physiological mechanisms involved in the adaptive responses to vibration exposure, and of the most appropriate vibration parameters to be used in order to maximize gains and improve safety. The effectiveness of this novel exercise modality on musculoskeletal structures is examined in this review. The physiological mechanisms involved in the adaptive responses to vibration exercise are discussed and suggestions for future studies are made.

  16. Whole-body vibration exposure: a comprehensive field study.

    PubMed

    Ozkaya, N; Willems, B; Goldsheyder, D

    1994-12-01

    A comprehensive field study investigated whole-body vibration exposure levels experienced by the train operators of a large metropolitan subway system. The purposes of the study were to measure mechanical vibrations transmitted to the seated train operators, to calculate daily whole-body vibration exposure levels, and to compare these levels with maximum acceptable exposure levels recommended by the international standard on whole-body vibration (ISO 2631). The study also sought to identify factors that may influence mechanical vibrations transmitted to the operators and quantify their effects on the measured vibration levels. The study was carried out by dividing the subway system into subway lines, each line into southbound and northbound directions, and each direction into station-to-station observations. Triaxial measurements were made on all subway lines and for all car types used in the system. For each line, at least two round trips of data were collected. Time-weighted averages of the two sets of data were used for final presentation. A total of 48 round trips were made and more than 100 hours of vibration data was collected and analyzed. All phases of the study were carried out in accordance with the procedures outlined in ISO 2631. It was determined that 6 out of 20 subway lines had vibration levels higher than daily exposure limits recommended by ISO 2631. It was also determined that train speed was the most significant factor influencing vibration exposure levels.

  17. Predicting and controlling risks from human exposures to vibration and mechanical shock: flag waving and flag weaving.

    PubMed

    Griffin, Michael J

    2015-01-01

    At work or in leisure activities, many people are exposed to vibration or mechanical shocks associated with risks of injury or disease. This paper identifies information that can be used to decide whether there may be a risk from exposure to hand-transmitted vibration or whole-body vibration and shock, and suggests actions that can control the risks. The complex and time-varying nature of human exposures to vibration and shock, the complexity of the different disorders and uncertainty as to the mechanisms of injury and the factors influencing injury have prevented the definition of dose-response relationships well proven by scientific study. It is necessary to wave a flag indicating when there is a need to control risks from exposure to vibration and shock while scientific enquiry provides understanding needed to weave a better flag. It is concluded that quantifying exposure severity is often neither necessary nor sufficient to either identify risks or implement measures that control the risks. The identification of risks associated with exposure to vibration and mechanical shock cannot, and need not, rely solely on the quantification of exposure severity. Qualitative methods can provide a sufficient indication of the need for control measures, which should not be restricted to reducing standardised measures of exposure severity.

  18. The SOBANE strategy for the management of risk, as applied to whole-body or hand-arm vibration.

    PubMed

    Malchaire, J; Piette, A

    2006-06-01

    The objective was to develop a coherent set of methods to be used effectively in industry to prevent and manage the risks associated with exposure to vibration, by coordinating the progressive intervention of the workers, their management, the occupational health and safety (OHS) professionals and the experts. The methods were developed separately for the exposure to whole-body and hand-arm vibration. The SOBANE strategy of risk prevention includes four levels of intervention: level 1, Screening; level 2, Observation; level 3, Analysis and; level 4, Expertise. The methods making it possible to apply this strategy were developed for 14 types of risk factors. The article presents the methods specific to the prevention of the risks associated with the exposure to vibration. The strategy is similar to those published for the risks associated with exposure to noise, heat and musculoskeletal disorders. It explicitly recognizes the qualifications of the workers and their management with regard to the work situation and shares the principle that measuring the exposure of the workers is not necessarily the first step in order to improve these situations. It attempts to optimize the recourse to the competences of the OHS professionals and the experts, in order to come more rapidly, effectively and economically to practical control measures.

  19. Dose-response patterns for vibration-induced white finger

    PubMed Central

    Griffin, M; Bovenzi, M; Nelson, C

    2003-01-01

    Aims: To investigate alternative relations between cumulative exposures to hand-transmitted vibration (taking account of vibration magnitude, lifetime exposure duration, and frequency of vibration) and the development of white finger (Raynaud's phenomenon). Methods: Three previous studies have been combined to provide a group of 1557 users of powered vibratory tools in seven occupational subgroups: stone grinders, stone carvers, quarry drillers, dockyard caulkers, dockyard boilermakers, dockyard painters, and forest workers. The estimated total operating duration in hours was thus obtained for each subject, for each tool, and for all tools combined. From the vibration magnitudes and exposure durations, seven alternative measurements of cumulative exposure were calculated for each subject, using expressions of the form: dose = ∑amiti, where ai is the acceleration magnitude on tool i, ti is the lifetime exposure duration for tool i, and m = 0, 1, 2, or 4. Results: For all seven alternative dose measures, an increase in dose was associated with a significant increase in the occurrence of vibration-induced white finger, after adjustment for age and smoking. However, dose measures with high powers of acceleration (m > 1) faired less well than measures in which the weighted or unweighted acceleration, and lifetime exposure duration, were given equal weight (m = 1). Dose determined solely by the lifetime exposure duration (without consideration of the vibration magnitude) gave better predictions than measures with m greater than unity. All measures of dose calculated from the unweighted acceleration gave better predictions than the equivalent dose measures using acceleration frequency-weighted according to current standards. Conclusions: Since the total duration of exposure does not discriminate between exposures accumulated over the day and those accumulated over years, a linear relation between vibration magnitude and exposure duration seems appropriate for predicting

  20. Acoustic and Vibration Environment for Crew Launch Vehicle Mobile Launcher

    NASA Technical Reports Server (NTRS)

    Vu, Bruce T.

    2007-01-01

    A launch-induced acoustic environment represents a dynamic load on the exposed facilities and ground support equipment (GSE) in the form of random pressures fluctuating around the ambient atmospheric pressure. In response to these fluctuating pressures, structural vibrations are generated and transmitted throughout the structure and to the equipment items supported by the structure. Certain equipment items are also excited by the direct acoustic input as well as by the vibration transmitted through the supporting structure. This paper presents the predicted acoustic and vibration environments induced by the launch of the Crew Launch Vehicle (CLV) from Launch Complex (LC) 39. The predicted acoustic environment depicted in this paper was calculated by scaling the statistically processed measured data available from Saturn V launches to the anticipated environment of the CLV launch. The scaling was accomplished by using the 5-segment Solid Rocket Booster (SRB) engine parameters. Derivation of vibration environment for various Mobile Launcher (ML) structures throughout the base and tower was accomplished by scaling the Saturn V vibration environment.

  1. Analysis of different vibration patterns to guide blind people.

    PubMed

    Durá-Gil, Juan V; Bazuelo-Ruiz, Bruno; Moro-Pérez, David; Mollà-Domenech, Fernando

    2017-01-01

    The literature indicates the best vibration positions and frequencies on the human body where tactile information is transmitted. However, there is a lack of knowledge about how to combine tactile stimuli for navigation. The aim of this study is to compare different vibration patterns outputted to blind people and to determine the most intuitive vibration patterns to indicate direction for navigation purposes through a tactile belt. The vibration patterns that stimulate the front side of the waist are preferred for indicating direction. Vibration patterns applied on the back side of the waist could be suitable for sending messages such as stop.

  2. Sensitivity of Crustaceans to Substrate-Borne Vibration.

    PubMed

    Roberts, Louise; Breithaupt, Thomas

    2016-01-01

    There is increasing interest in the responsiveness of crustaceans to vibrations, especially in the context of marine developments where techniques such as pile driving create strong vibrations that are readily transmitted through the seabed. Experiments were undertaken under controlled conditions to investigate the sensitivity of unconditioned crustaceans to substrate-borne vibration. The subjects were exposed to a range of frequencies and amplitudes using the staircase method of presentation to determine the thresholds of response. Behavior varied according to the strength of the stimuli and included bursts of movement and rapid bouts of movement.

  3. A critique of a UK standardized test of finger rewarming after cold provocation in the diagnosis and staging of hand-arm vibration syndrome.

    PubMed

    Mason, H J; Poole, K; Saxton, J

    2003-08-01

    Accurate diagnosis and staging of hand-arm vibration syndrome (HAVS) is important in health surveillance of vibration-exposed workers and the substantial number of related medico-legal cases. The measurement of the rewarming rate of fingers after cold provocation to the hands (CPT) has been suggested as a useful test in diagnosing HAVS. To investigate the diagnostic value of a standardized version of the CPT test using a 15 degrees C cold challenge for 5 min applied in the recent compensation assessment of UK miners. Analysis of a subset of UK miners assessed at our unit, together with data from a small repeatability study of the standardized CPT in normal subjects. Rewarming time in the CPT was significantly lower in those subjects classified as vascular Stockholm stage 0 compared with Stockholm stages 1-3 combined, but did not discriminate between the stages of abnormality. Using the suggested cut-off in the CPT test, the sensitivity and specificity were calculated as 43 and 78%, respectively. Receiver operator characteristic analysis suggested that the rewarming time of highest accuracy gave a sensitivity of 66% and specificity of 59%. In 10 miners who reported unilateral hand blanching, there was no significant difference in CPT measurements between blanching and non-blanching hands. Repeat CPT measurements in normal subjects suggested mean differences of 52 and 107 s for each hand, and the Bland-Altman coefficient of repeatability was approximately 600 s for all fingers. Single application of this standardized CPT test may have limited value in diagnosing the vascular component of HAVS in an individual.

  4. Health risks of vibration exposure to wheelchair users in the community

    PubMed Central

    Garcia-Mendez, Yasmin; Pearlman, Jonathan L.; Boninger, Michael L.; Cooper, Rory A.

    2013-01-01

    Objective The purpose of this study was to evaluate whole-body vibration (WBV) exposure to wheelchair (WC) users in their communities and to determine the effect of WC frame type (folding, rigid, and suspension) in reducing WBV transmitted to the person. Design An observational case-control study of the WBV exposure levels among WC users. Participants Thirty-seven WC users, with no pressure sores, 18 years old or older and able to perform independent transfers. Main outcome measures WC users were monitored for 2 weeks to collect WBV exposure, as well as activity levels, by using custom vibration and activity data-loggers. Vibration levels were evaluated using ISO 2631-1 methods. Results All WC users who participated in this study were continuously exposed to WBV levels at the seat that were within and above the health caution zone specified by ISO 2631-1 during their day-to-day activities (0.83 ± 0.17 m/second2, weighted root-mean-squared acceleration, for 13.07 ± 3.85 hours duration of exposure). WCs with suspension did not attenuate vibration transmitted to WC users (V = 0.180, F(8, 56) = 0.692, P = 0.697). Conclusions WBV exposure to WC users exceeds international standards. Suspension systems need to be improved to reduce vibrations transmitted to the users. PMID:23820152

  5. Nonlinear Vibrational Spectroscopy: a Method to Study Vibrational Self-Trapping

    NASA Astrophysics Data System (ADS)

    Hamm, Peter; Edler, Julian

    We review the capability of nonlinear vibrational spectroscopy to study vibrational self-trapping in hydrogen-bonded molecular crystals. For that purpose, the two relevant coupling mechanisms, excitonic coupling and nonlinear exciton-phonon coupling, are first introduced separately using appropriately chosen molecular systems as examples. Both coupling mechanisms are subsequently combined, yielding vibrational selftrapping. The experiments unambiguously prove that both the N-H and the C=O band of crystalline acetanilide (ACN), a model system for proteins, show vibrational self-trapping. The C=O band is self-trapped only at low enough temperature, while thermally induced disorder destroys the mechanism at room temperature. The binding energy of the N-H band, on the other hand, is considerably larger and self-trapping survives thermal fluctuations even at room temperature.

  6. Ergonomic analysis of fastening vibration based on ISO Standard 5349 (2001).

    PubMed

    Joshi, Akul; Leu, Ming; Murray, Susan

    2012-11-01

    Hand-held power tools used for fastening operations exert high dynamic forces on the operator's hand-arm, potentially causing injuries to the operator in the long run. This paper presents a study that analyzed the vibrations exerted by two hand-held power tools used for fastening operations with the operating exhibiting different postures. The two pneumatic tools, a right-angled nut-runner and an offset pistol-grip, are used to install shearing-type fasteners. A tri-axial accelerometer is used to measure the tool's vibration. The position and orientation of the transducer mounted on the tool follows the ISO-5349 Standard. The measured vibration data is used to compare the two power tools at different operating postures. The data analysis determines the number of years required to reach a 10% probability of developing finger blanching. The results indicate that the pistol-grip tool induces more vibration in the hand-arm than the right-angled nut-runner and that the vibrations exerted on the hand-arm vary for different postures. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  7. Actively controlled vibration welding system and method

    DOEpatents

    Cai, Wayne W.; Kang, Bongsu; Tan, Chin-An

    2013-04-02

    A vibration welding system includes a controller, welding horn, an active material element, and anvil assembly. The assembly may include an anvil body connected to a back plate and support member. The element, e.g., a piezoelectric stack or shape memory alloy, is positioned with respect to the assembly. The horn vibrates in a desirable first direction to form a weld on a work piece. The element controls any vibrations in a second direction by applying calibrated response to the anvil body in the second direction. A method for controlling undesirable vibrations in the system includes positioning the element with respect to the anvil assembly, connecting the anvil body to the support member through the back plate, vibrating the horn in a desirable first direction, and transmitting an input signal to the element to control vibration in an undesirable second direction.

  8. Can sensation of cold hands predict Raynaud's phenomenon or paraesthesia?

    PubMed

    Carlsson, D; Wahlström, J; Burström, L; Hagberg, M; Lundström, R; Pettersson, H; Nilsson, T

    2018-05-10

    Raynaud's phenomenon and neurosensory symptoms are common after hand-arm vibration exposure. Knowledge of early signs of vibration injuries is needed. To investigate the risk of developing Raynaud's phenomenon and paraesthesia in relation to sensation of cold hands in a cohort of male employees at an engineering plant. We followed a cohort of male manual and office workers at an engineering plant in Sweden for 21 years. At baseline (1987 and 1992) and each follow-up (1992, 1997, 2002, 2008), we assessed sensation of cold, Raynaud's phenomenon and paraesthesia in the hands using questionnaires and measured vibration exposure. We calculated risk estimates with univariate and multiple logistic regression analyses and adjusted for vibration exposure and tobacco usage. There were 241 study participants. During the study period, 21 individuals developed Raynaud's phenomenon and 43 developed paraesthesia. When adjusting the risk of developing Raynaud's phenomenon for vibration exposure and tobacco use, the odds ratios were between 6.0 and 6.3 (95% CI 2.2-17.0). We observed no increased risk for paraesthesia in relation to a sensation of cold hands. A sensation of cold hands was a risk factor for Raynaud's phenomenon. At the individual level, reporting a sensation of cold hands did not appear to be useful information to predict future development of Raynaud's phenomenon given a weak to moderate predictive value. For paraesthesia, the sensation of cold was not a risk factor and there was no predictive value at the individual level.

  9. Disability in the upper extremity and quality of life in hand-arm vibration syndrome.

    PubMed

    Poole, Kerry; Mason, Howard

    2005-11-30

    To investigate whether hand-arm vibration syndrome (HAVS) leads to disability in the upper extremity or deficit in quality of life (QoL) using validated questionnaire tools, and to establish whether these effects are related to the Stockholm Workshop Staging (SWS). This was a postal cross-sectional questionnaire study with a 50% response rate. Four hundred and forty-four males, who had been diagnosed and staged according to the SWS were sent the Disability in the Arm, Shoulder and Hand (DASH) and the SF-36v2 QoL questionnaires. HAVS cases had significantly greater DASH disability scores and reduced QoL physical and mental component scores compared to published normal values. Those HAVS cases with a presumptive diagnosis of Carpal Tunnel Syndrome(CTS) had even higher disability scores. There was a clear, linear relationship between both the DASH disability score and the physical component of the QoL and sensorineural SWS, but not with the vascular SWS. HAVS has a significant effect on an individual's perceived ability to perform everyday tasks involving the upper extremity, and their quality of life. Physical capability may be further compromised in those individuals who have a presumptive diagnosis of CTS. These findings may have important implications regarding management of the affected worker.

  10. Transmission of vibration through gloves: effects of contact area.

    PubMed

    Md Rezali, Khairil Anas; Griffin, Michael J

    2017-01-01

    For three samples of material (12.5, 25.0 and 37.5 mm diameter) from each of three gloves, the dynamic stiffnesses and the vibration transmissibilities of the materials (to both the palm of the hand and the thenar eminence) were measured at frequencies from 10 to 300 Hz. Additional measurements showed the apparent masses of the hand at the palm and the thenar eminence were independent of contact area at frequencies less than about 40 Hz, but increased with increasing area at higher frequencies. The stiffness and damping of the glove materials increased with increasing area. These changes caused material transmissibilities to the hand to increase with increasing area. It is concluded that the size of the area of contact has a large influence on the transmission of vibration through a glove to the hand. The area of contact should be well-defined and controlled when evaluating the transmission of vibration through gloves. Practitioner Summary: The transmission of vibration through gloves depends on both the dynamic stiffness of glove material and the dynamic response of the hand. Both of these depend on the size of the contact area between a glove material and the hand, which should be taken into account when assessing glove transmissibility.

  11. On the control of vibrations using synchrophasing

    NASA Astrophysics Data System (ADS)

    Dench, M. R.; Brennan, M. J.; Ferguson, N. S.

    2013-09-01

    This paper describes the application of a technique, known as synchrophasing, to the control of machinery vibration. It is applicable to machinery installations, in which several synchronous machines, such as those driven by electrical motors, are fitted to an isolated common structure known as a machinery raft. To reduce the vibration transmitted to the host structure to which the machinery raft is attached, the phase of the electrical supply to the motors is adjusted so that the net transmitted force to the host structure is minimised. It is shown that while this is relatively simple for an installation consisting of two machines, it is more complicated for installations in which there are more than two machines, because of the interaction between the forces generated by each machine. The development of a synchrophasing scheme, which has been applied to propeller aircraft, and is known as Propeller Signature Theory (PST) is discussed. It is shown both theoretically and experimentally, that this is an efficient way of controlling the phase of multiple machines. It is also shown that synchrophasing is a worthwhile vibration control technique, which has the potential to suppress vibration transmitted to the host structure by up to 20 dB at certain frequencies. Although the principle of synchronisation has been demonstrated on a one-dimensional structure, it is believed that this captures the key features of the approach. However, it should be realised that the mode-shapes of a machinery raft may be more complex than that of a one-dimensional structure and this may need to be taken into account in a real application.

  12. Remote vibration monitoring system using wireless internet data transfer

    NASA Astrophysics Data System (ADS)

    Lemke, John

    2000-06-01

    Vibrations from construction activities can affect infrastructure projects in several ways. Within the general vicinity of a construction site, vibrations can result in damage to existing structures, disturbance to people, damage to sensitive machinery, and degraded performance of precision instrumentation or motion sensitive equipment. Current practice for monitoring vibrations in the vicinity of construction sites commonly consists of measuring free field or structural motions using velocity transducers connected to a portable data acquisition unit via cables. This paper describes an innovative way to collect, process, transmit, and analyze vibration measurements obtained at construction sites. The system described measures vibration at the sensor location, performs necessary signal conditioning and digitization, and sends data to a Web server using wireless data transmission and Internet protocols. A Servlet program running on the Web server accepts the transmitted data and incorporates it into a project database. Two-way interaction between the Web-client and the Web server is accomplished through the use of a Servlet program and a Java Applet running inside a browser located on the Web client's computer. Advantages of this system over conventional vibration data logging systems include continuous unattended monitoring, reduced costs associated with field data collection, instant access to data files and graphs by project team members, and the ability to remotely modify data sampling schemes.

  13. Vibration in car repair work.

    PubMed

    Hansson, J E; Eklund, L; Kihlberg, S; Ostergren, C E

    1987-03-01

    The main objective of the study was to find efficient hand tools which caused only minor vibration loading. Vibration measurements were carried out under standardised working conditions. The time during which car body repairers in seven companies were exposed to vibration was determined. Chisel hammers, impact wrenches, sanders and saws were the types of tools which generated the highest vibration accelerations. The average daily exposure at the different garages ranged from 22 to 70 min. The risk of vibration injury is currently rated as high. The difference between the highest and lowest levels of vibration was considerable in most tool categories. Therefore the choice of tool has a major impact on the magnitude of vibration exposure. The importance of choosing the right tools and working methods is discussed and a counselling service on vibration is proposed.

  14. Postocclusive reactive hyperemia in hand-arm vibration syndrome.

    PubMed

    Stoyneva, Zlatka

    2016-01-01

    To assess laser Doppler-recorded postocclusive reactive hyperemic responses in vibration-induced Raynaud's phenomenon and compare it with primary and secondary to sclerodermy Raynaud's phenomenon. Thirty patients with vibration-induced Raynaud's phenomenon and 30 healthy controls and patients with primary and secondary to sclerodermy Raynaud's phenomenon were investigated. Fingerpulp skin blood flow was monitored by laser Doppler flowmetry during postocclusive reactive hyperemia test. Lower initial perfusion values were established in all the patients with Raynaud's phenomenon compared to the healthy controls (p < 0.0001). The postocclusive reactive hyperemic peak was lower in all the Raynaud's phenomenon groups compared to the controls (p < 0.0001). The postocclusive and basal perfusions were lower in the secondary Raynaud's phenomenon groups compared to the control and the primary Raynaud's phenomenon groups (p < 0.0001). The velocities to postocclusive hyperemic peak were lower in all the Raynaud's phenomenon patients (p < 0.0001), so were in the vibration-induced (p < 0.002) and the sclerodermy Raynaud's phenomenon (p < 0.004) groups in relation to the primary Raynaud's phenomenon group. The perfusion values and the velocities were significantly influenced by the initial superficial skin temperatures and perfusions, while the velocities were dependent also on gender, and the hyperemic peak on age. Postocclusive reactive hyperemia is abnormal in all Raynaud's phenomenon patients. Laser Doppler-recorded reactive hyperemia test contributes to diagnosing Raynaud's phenomenon and has proved to be valuable for group analysis. The applied method is not sensitive enough to discriminate adequately the type of Raynaud's phenomenon among individual cases. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  15. Using Piezoelectric Devices to Transmit Power through Walls

    NASA Technical Reports Server (NTRS)

    Sherrit, Stewart; Bar-Cohen, Yoseph; Bao, Xiaoqi

    2008-01-01

    A method denoted wireless acoustic-electric feed-through (WAEF) has been conceived for transmitting power and/or data signals through walls or other solid objects made of a variety of elastic materials that could be electrically conductive or nonconductive. WAEF would make it unnecessary to use wires, optical fibers, tubes, or other discrete wall-penetrating signal-transmitting components, thereby eliminating the potential for structural weakening or leakage at such penetrations. Avoidance of such penetrations could be essential in some applications in which maintenance of pressure, vacuum, or chemical or biological isolation is required. In a basic WAEF setup, a transmitting piezoelectric transducer on one side of a wall would be driven at resonance to excite ultrasonic vibrations in the wall. A receiving piezoelectric transducer on the opposite side of the wall would convert the vibrations back to an ultrasonic AC electric signal, which would then be detected and otherwise processed in a manner that would depend on the modulation (if any) applied to the signal and whether the signal was used to transmit power, data, or both. An electromechanical-network model has been derived as a computationally efficient means of analyzing and designing a WAEF system. This model is a variant of a prior model, known in the piezoelectric-transducer art as Mason's equivalent-circuit model, in which the electrical and mechanical dynamics, including electromechanical couplings, are expressed as electrical circuit elements that can include inductors, capacitors, and lumped-parameter complex impedances. The real parts of the complex impedances are used to account for dielectric, mechanical, and coupling losses in all components (including all piezoelectric-transducer, wall, and intermediate material layers). In an application to a three-layer piezoelectric structure, this model was shown to yield the same results as do solutions of the wave equations of piezoelectricity and acoustic

  16. Spatial resonance in a small artery excited by vibration input as a possible mechanism to cause hand-arm vascular disorders

    NASA Astrophysics Data System (ADS)

    Pattnaik, Shrikant; Banerjee, Rupak; Kim, Jay

    2012-04-01

    Hand-arm vibration syndrome (HAVS) is collectively a vasospastic and neurodegenerative occupational disease. One of the major symptoms of HAVS is vibration white finger (VWF) caused by exaggerated vasoconstriction of the arteries and skin arterioles. While VWF is a very painful and costly occupational illness, its pathology has not been well understood. In this study a small artery is modeled as a fluid filled elastic tube whose diameter changes along the axial direction. Equations of motion are developed by considering interactions between the fluid, artery wall and soft-tissue bed. It is shown that the resulting wave equation is the same as that of the basilar membrane in the cochlea of mammals. Therefore, the artery system shows a spatial resonance as in the basilar membrane, which responds with the highest amplitude at the location determined by the vibration frequency. This implies that a long-term use of one type of tool will induce high-level stresses at a few identical locations of the artery that correspond to the major frequency components of the tool. Hardening and deterioration of the artery at these locations may be a possible cause of VWF.

  17. Laboratory and field measurements and evaluations of vibration at the handles of riveting hammers

    PubMed Central

    McDOWELL, THOMAS W.; WARREN, CHRISTOPHER; WELCOME, DANIEL E.; DONG, REN G.

    2015-01-01

    The use of riveting hammers can expose workers to harmful levels of hand-transmitted vibration (HTV). As a part of efforts to reduce HTV exposures through tool selection, the primary objective of this study was to evaluate the applicability of a standardized laboratory-based riveting hammer assessment protocol for screening riveting hammers. The second objective was to characterize the vibration emissions of reduced vibration riveting hammers and to make approximations of the HTV exposures of workers operating these tools in actual work tasks. Eight pneumatic riveting hammers were selected for the study. They were first assessed in a laboratory using the standardized method for measuring vibration emissions at the tool handle. The tools were then further assessed under actual working conditions during three aircraft sheet metal riveting tasks. Although the average vibration magnitudes of the riveting hammers measured in the laboratory test were considerably different from those measured in the field study, the rank orders of the tools determined via these tests were fairly consistent, especially for the lower vibration tools. This study identified four tools that consistently exhibited lower frequency-weighted and unweighted accelerations in both the laboratory and workplace evaluations. These observations suggest that the standardized riveting hammer test is acceptable for identifying tools that could be expected to exhibit lower vibrations in workplace environments. However, the large differences between the accelerations measured in the laboratory and field suggest that the standardized laboratory-based tool assessment is not suitable for estimating workplace riveting hammer HTV exposures. Based on the frequency-weighted accelerations measured at the tool handles during the three work tasks, the sheet metal mechanics assigned to these tasks at the studied workplace are unlikely to exceed the daily vibration exposure action value (2.5 m s−2) using any of the

  18. Equal vibrotactile sense thresholds of the fingers and its diagnostic significance for hand-arm vibration syndrome.

    PubMed

    Cheng, H; Zhang, X C; Duan, L; Ma, Y; Wang, J X

    1995-01-01

    The vibrotactile sense thresholds (VSTs) of the middle fingers of 60 healthy persons and 97 patients with Hand-Arm Vibration Syndrome (HAVS) or subclinical HAVS were measured quantitatively. Intermittent vibratory irritations were adopted, with vibration stimulus frequencies at 8, 16, 31.5, 63, 125, 250, and 500 Hz. The equal VST contours of the fingers were mapped. Results showed that the VSTs of the normal group were not correlated with sex or handedness. From 8 Hz to 250 Hz the equal VST contours of the normal group were relatively flat; at more than 250 Hz the contours began an abrupt ascent. The VST values had a logarithmic rising tendency with the increasing age of subjects. In the equal VST contours the frequency of the most sensitive threshold value was 125 Hz in the normal group and 8 Hz in the HAVS group. The patients' VST values were higher than that of the healthy persons. The vibrotactilegram showed that the VST values of the patient groups first shifted at high frequencies and VST loss displayed a "V"-type hollow at 125 Hz and 250 Hz. The quantitative test method of VST was a valuable auxiliary detection method for HAVS. The "V"-type hollow of VST was an early clinical manifestation of HAVS.

  19. Nematode infections: soil-transmitted helminths and trichinella.

    PubMed

    Knopp, Stefanie; Steinmann, Peter; Keiser, Jennifer; Utzinger, Jürg

    2012-06-01

    Infection with soil-transmitted helminths occurs via ingestion of nematode eggs with contaminated food and water, via hands, or inhalation of dust, or by penetration of larvae through the skin. Trichinella infections are caused by the ingestion of larvae contained in undercooked meat. In highly endemic areas, preventive chemotherapy (ie, regular administration of anthelmintic drugs to at-risk populations) is the key strategy against soil-transmitted helminthiasis. Integrated control approaches, including improved hygiene, sanitation, and water, are required for lasting effects. Because of growing tourism, travel, and migration, clinicians and specialized travel clinics must remain aware of the diagnosis, prevention, and treatment of soil-transmitted helminth and Trichinella infections. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. VibeComm: radio-free wireless communication for smart devices using vibration.

    PubMed

    Hwang, Inhwan; Cho, Jungchan; Oh, Songhwai

    2014-11-10

    This paper proposes VibeComm, a novel communication method for smart devices using a built-in vibrator and accelerometer. The proposed approach is ideal for low-rate off-line communication, and its communication medium is an object on which smart devices are placed, such as tables and desks. When more than two smart devices are placed on an object and one device wants to transmit a message to the other devices, the transmitting device generates a sequence of vibrations. The vibrations are propagated through the object on which the devices are placed. The receiving devices analyze their accelerometer readings to decode incoming messages. The proposed method can be the alternative communication method when general types of radio communication methods are not available. VibeComm is implemented on Android smartphones, and a comprehensive set of experiments is conducted to show its feasibility.

  1. Noise and hand-arm vibration exposure in relation to the risk of hearing loss.

    PubMed

    Pettersson, Hans; Burström, Lage; Hagberg, Mats; Lundström, Ronnie; Nilsson, Tohr

    2012-01-01

    The aim of this study was to examine the possible association of combined exposure of noise and hand-arm vibration (HAV) and the risk of noise-induced hearing loss. Workers in a heavy engineering industry were part of a dynamic cohort. Of these workers, 189 had HAV exposure, and their age and hearing status were recorded in the same year and were, therefore, included in the analysis. Data on HAV duration and acceleration was gathered through questionnaires, observations, and measurements. All available audiograms were categorized into normal and hearing loss. The first exposure variable included the lifetime HAV exposure. The lifetime HAV exposure was multiplied by the acceleration of HAV for the second and third exposure variable. Logistic regression using the Generalized Estimation Equations method was chosen to analyze the data to account for the repeated measurements. The analysis was performed with both continuous exposure variables and with exposure variables grouped into exposure quartiles with hearing loss as an outcome and age as a covariate. With continuous exposure variables, the odds ratio (OR) with a 95% confidence interval (CI) for hearing loss was equal to or greater than one for all exposure variables. When the exposure variables were grouped into quartiles, the OR with a 95% CI was greater than one at the third and fourth quartile. The results show that working with vibrating machines in an environment with noise exposure increases the risk of hearing loss, supporting an association between exposure to noise and HAV, and the noise-induced hearing loss.

  2. Effect of Wheelchair Frame Material on Users' Mechanical Work and Transmitted Vibration

    PubMed Central

    Aissaoui, Rachid

    2014-01-01

    Wheelchair propulsion exposes the user to a high risk of shoulder injury and to whole-body vibration that exceeds recommendations of ISO 2631-1:1997. Reducing the mechanical work required to travel a given distance (WN-WPM, weight-normalized work-per-meter) can help reduce the risk of shoulder injury, while reducing the vibration transmissibility (VT) of the wheelchair frame can reduce whole-body vibration. New materials such as titanium and carbon are used in today's wheelchairs and are advertised to improve both parameters, but current knowledge on this matter is limited. In this study, WN-WPM and VT were measured simultaneously and compared between six folding wheelchairs (1 titanium, 1 carbon, and 4 aluminium). Ten able-bodied users propelled the six wheelchairs on three ground surfaces. Although no significant difference of WN-WPM was found between wheelchairs (P < 0.1), significant differences of VT were found (P < 0.05). The carbon wheelchair had the lowest VT. Contrarily to current belief, the titanium wheelchair VT was similar to aluminium wheelchairs. A negative correlation between VT and WN-WPM was found, which means that reducing VT may be at the expense of increasing WN-WPM. Based on our results, use of carbon in wheelchair construction seems promising to reduce VT without increasing WN-WPM. PMID:25276802

  3. Vibration Power Flow In A Constrained Layer Damping Cylindrical Shell

    NASA Astrophysics Data System (ADS)

    Wang, Yun; Zheng, Gangtie

    2012-07-01

    In this paper, the vibration power flow in a constrained layer damping (CLD) cylindrical shell using wave propagation approach is investigated. The dynamic equations of the shell are derived with the Hamilton principle in conjunction with the Donnell shell assumption. With these equations, the dynamic responses of the system under a line circumferential cosine harmonic exciting force is obtained by employing the Fourier transform and the residue theorem. The vibration power flows inputted to the system and transmitted along the shell axial direction are both studied. The results show that input power flow varies with driving frequency and circumferential mode order, and the constrained damping layer can obviously restrict the exciting force from inputting power flow into the base shell especially for a thicker viscoelastic layer, a thicker or stiffer constraining layer (CL), and a higher circumferential mode order, can rapidly attenuate the vibration power flow transmitted along the base shell axial direction.

  4. Remote monitoring of vibrational information in spider webs.

    PubMed

    Mortimer, B; Soler, A; Siviour, C R; Vollrath, F

    2018-05-22

    Spiders are fascinating model species to study information-acquisition strategies, with the web acting as an extension of the animal's body. Here, we compare the strategies of two orb-weaving spiders that acquire information through vibrations transmitted and filtered in the web. Whereas Araneus diadematus monitors web vibration directly on the web, Zygiella x-notata uses a signal thread to remotely monitor web vibration from a retreat, which gives added protection. We assess the implications of these two information-acquisition strategies on the quality of vibration information transfer, using laser Doppler vibrometry to measure vibrations of real webs and finite element analysis in computer models of webs. We observed that the signal thread imposed no biologically relevant time penalty for vibration propagation. However, loss of energy (attenuation) was a cost associated with remote monitoring via a signal thread. The findings have implications for the biological use of vibrations by spiders, including the mechanisms to locate and discriminate between vibration sources. We show that orb-weaver spiders are fascinating examples of organisms that modify their physical environment to shape their information-acquisition strategy.

  5. Remote monitoring of vibrational information in spider webs

    NASA Astrophysics Data System (ADS)

    Mortimer, B.; Soler, A.; Siviour, C. R.; Vollrath, F.

    2018-06-01

    Spiders are fascinating model species to study information-acquisition strategies, with the web acting as an extension of the animal's body. Here, we compare the strategies of two orb-weaving spiders that acquire information through vibrations transmitted and filtered in the web. Whereas Araneus diadematus monitors web vibration directly on the web, Zygiella x-notata uses a signal thread to remotely monitor web vibration from a retreat, which gives added protection. We assess the implications of these two information-acquisition strategies on the quality of vibration information transfer, using laser Doppler vibrometry to measure vibrations of real webs and finite element analysis in computer models of webs. We observed that the signal thread imposed no biologically relevant time penalty for vibration propagation. However, loss of energy (attenuation) was a cost associated with remote monitoring via a signal thread. The findings have implications for the biological use of vibrations by spiders, including the mechanisms to locate and discriminate between vibration sources. We show that orb-weaver spiders are fascinating examples of organisms that modify their physical environment to shape their information-acquisition strategy.

  6. Differential effect of muscle vibration on intracortical inhibitory circuits in humans

    PubMed Central

    Rosenkranz, Karin; Rothwell, John C

    2003-01-01

    Low amplitude muscle vibration (0.5 ms; 80 Hz; duration 1.5 s) was applied in turn to each of three different intrinsic hand muscles (first dorsal interosseus, FDI; abductor pollicis brevis, APB; and abductor digiti minimi, ADM) in order to test its effect on the EMG responses evoked by transcranial magnetic stimulation (TMS). Recordings were also taken from flexor and extensor carpi radialis (FCR and ECR, respectively). We evaluated the amplitude of motor evoked potentials (MEPs) produced by a single TMS pulse, short interval intracortical inhibition and facilitation (SICI and ICF) and long interval intracortical inhibition (LICI). TMS pulses were applied 1 s after the start of vibration with subjects relaxed throughout. Vibration increased the amplitude of MEPs evoked in the vibrated muscle (162 ± 6 % of MEP with no vibration; mean ± s.e.m.), but suppressed MEPs in the two non-vibrated hand muscles (72 ± 9 %). Compared with no vibration (test response reduced to 51 ± 5 % of control), there was less SICI in the vibrated muscle (test response reduced to 92 ± 28 % of control) and more in the non-vibrated hand muscles (test response reduced to 27 ± 5 % of control). The opposite occurred for LICI: compared with the no vibration condition (test response reduced to 33 ± 6 % control), there was more LICI in the vibrated muscle (test response reduced to 17 ± 3 % control) than in the non-vibrated hand muscles (test response reduced to 80 ± 11 % control) even when the intensity of the test stimulus was adjusted to compensate for the changes in baseline MEP. There was no effect on ICF. Cutaneous stimulation of the index finger (80 Hz, 1.5 s duration, twice sensory threshold) had no consistent differential effect on any of the parameters. We conclude that vibratory input from muscle can differentially modulate excitability in motor cortical circuits. PMID:12821723

  7. Fingertip contact suppresses the destabilizing influence of leg muscle vibration

    NASA Technical Reports Server (NTRS)

    Lackner, J. R.; Rabin, E.; DiZio, P.

    2000-01-01

    Touch of the hand with a stationary surface at nonmechanically supportive force levels (<1 N) greatly attenuates postural sway during quiet stance. We predicted such haptic contact would also suppress the postural destabilization caused by vibrating the right peroneus brevis and longus muscles of subjects standing heel-to-toe with eyes closed. In experiment 1, ten subjects were tested under four conditions: no-vibration, no-touch; no-vibration, touch; vibration, no-touch; and vibration, touch. A hand-held physiotherapy vibrator (120 Hz) was applied approximately 5 cm above the malleolous to stimulate the peroneus longus and brevis tendons. Touch conditions involved contact of the right index finger with a laterally positioned surface (<1 N of force) at waist height. Vibration in the absence of finger contact greatly increased the mean sway amplitude of the center of pressure and of the head relative to the no-vibration, no-touch control condition (P < 0.001). The touch, no-vibration and touch-vibration conditions were not significantly different (P > 0.05) from each other and both had significantly less mean sway amplitude of head and of center of pressure than the other conditions (P < 0.01). In experiment 2, eight subjects stood heel-to-toe under touch and no-touch conditions involving 40-s duration trials of peroneus tendon vibration at different duty cycles: 1-, 2-, 3-, and 4-s ON and OFF periods. The vibrator was attached to the subject's leg and remotely activated. In the no-touch conditions, subjects showed periodic postural disruptions contingent on the duty cycle and mirror image rebounds with the offset of vibration. In the touch conditions, subjects were much less disrupted and showed compensations occurring within 500 ms of vibration onset and mirror image rebounds with vibration offset. Subjects were able to suppress almost completely the destabilizing influence of the vibration in the 3- and 4-s duty cycle trials. These experiments show that haptic

  8. Surface acoustic wave (SAW) vibration sensors.

    PubMed

    Filipiak, Jerzy; Solarz, Lech; Steczko, Grzegorz

    2011-01-01

    In the paper a feasibility study on the use of surface acoustic wave (SAW) vibration sensors for electronic warning systems is presented. The system is assembled from concatenated SAW vibration sensors based on a SAW delay line manufactured on a surface of a piezoelectric plate. Vibrations of the plate are transformed into electric signals that allow identification of the sensor and localization of a threat. The theoretical study of sensor vibrations leads us to the simple isotropic model with one degree of freedom. This model allowed an explicit description of the sensor plate movement and identification of the vibrating sensor. Analysis of frequency response of the ST-cut quartz sensor plate and a damping speed of its impulse response has been conducted. The analysis above was the basis to determine the ranges of parameters for vibrating plates to be useful in electronic warning systems. Generally, operation of electronic warning systems with SAW vibration sensors is based on the analysis of signal phase changes at the working frequency of delay line after being transmitted via two circuits of concatenated four-terminal networks. Frequencies of phase changes are equal to resonance frequencies of vibrating plates of sensors. The amplitude of these phase changes is proportional to the amplitude of vibrations of a sensor plate. Both pieces of information may be sent and recorded jointly by a simple electrical unit.

  9. Hand-arm vibration and the risk of vascular and neurological diseases—A systematic review and meta-analysis

    PubMed Central

    Wahlström, Jens; Burström, Lage

    2017-01-01

    Background Increased occurrence of Raynaud’s phenomenon, neurosensory injury and carpal tunnel syndrome has been reported for more than 100 years in association with work with vibrating machines. The current risk prediction modelling (ISO-5349) for “Raynaud’s phenomenon” is based on a few studies published 70 to 40 years ago. There are no corresponding risk prediction models for neurosensory injury or carpal tunnel syndrome, nor any systematic reviews comprising a statistical synthesis (meta-analysis) of the evidence. Objectives Our aim was to provide a systematic review of the literature on the association between Raynaud’s phenomenon, neurosensory injuries and carpal tunnel syndrome and hand-arm vibration (HAV) exposure. Moreover the aim was to estimate the magnitude of such an association using meta-analysis. Methods This systematic review covers the scientific literature up to January 2016. The databases used for the literature search were PubMed and Science Direct. We found a total of 4,335 abstracts, which were read and whose validity was assessed according to pre-established criteria. 294 articles were examined in their entirety to determine whether each article met the inclusion criteria. The possible risk of bias was assessed for each article. 52 articles finally met the pre-established criteria for inclusion in the systematic review. Results The results show that workers who are exposed to HAV have an increased risk of vascular and neurological diseases compared to non-vibration exposed groups. The crude estimate of the risk increase is approximately 4–5 fold. The estimated effect size (odds ratio) is 6.9 for the studies of Raynaud’s phenomenon when including only the studies judged to have a low risk of bias. The corresponding risk of neurosensory injury is 7.4 and the equivalent of carpal tunnel syndrome is 2.9. Conclusion At equal exposures, neurosensory injury occurs with a 3-time factor shorter latency than Raynaud’s phenomenon. Which

  10. Transmission of vibration through glove materials: effects of contact force.

    PubMed

    Md Rezali, Khairil Anas; Griffin, Michael J

    2018-04-26

    This study investigated effects of applied force on the apparent mass of the hand, the dynamic stiffness of glove materials and the transmission of vibration through gloves to the hand. For 10 subjects, 3 glove materials and 3 contact forces, apparent masses and glove transmissibilities were measured at the palm and at a finger at frequencies in the range 5-300 Hz. The dynamic stiffnesses of the materials were also measured. With increasing force, the dynamic stiffnesses of the materials increased, the apparent mass at the palm increased at frequencies greater than the resonance and the apparent mass at the finger increased at low frequencies. The effects of force on transmissibilities therefore differed between materials and depended on vibration frequency, but changes in apparent mass and dynamic stiffness had predictable effects on material transmissibility. Depending on the glove material, the transmission of vibration through a glove can be increased or decreased when increasing the applied force. Practitioner summary: Increasing the contact force (i.e. push force or grip force) can increase or decrease the transmission of vibration through a glove. The vibration transmissibilities of gloves should be assessed with a range of contact forces to understand their likely influence on the exposure of the hand and fingers to vibration.

  11. Metamaterial split ring resonator as a sensitive mechanical vibration sensor

    NASA Astrophysics Data System (ADS)

    Sikha Simon, K.; Chakyar, Sreedevi P.; Andrews, Jolly; Joseph V., P.

    2017-06-01

    This paper introduces a sensitive vibration sensor based on microwave metamaterial Split Ring Resonator (SRR) capable of detecting any ground vibration. The experimental setup consists of single Broad-side Coupled SRR (BCSRR) unit fixed on a cantilever capable of sensitive vibrations. It is arranged between transmitting and receiving probes of a microwave measurement system. The absorption level variations at the resonant frequency due to the displacement from the reference plane of SRR, which is a function of the strength of external mechanical vibration, is analyzed. This portable and cost effective sensor working on a single frequency is observed to be capable of detecting even very weak vibrations. This may find potential applications in the field of tamper-proofing, mining, quarrying and earthquake sensing.

  12. The effects of low-frequency vibrations on hepatic profile of blood

    NASA Astrophysics Data System (ADS)

    Damijan, Z.

    2008-02-01

    Body vibrations training has become popular in sports training, fitness activity, it is still a rare form of physical rehabilitation.. Vibrations are transmitted onto the whole body or some body parts of an exercising person via a vibration platform subjected to mechanical vertical vibrations. During the training session a participant has to maintain his body position or do exercises that engage specific muscles whilst vibrations of the platform are transmitted onto the person's body. This paper is the continuation of the earlier study covering the effects of low-frequency vibrations on selected physiological parameters of the human body. The experiments were conducted to find the answer to the question if vibration exposure (total duration of training sessions 6 hours 20 min) should produce any changes in hepatic profile of blood. Therefore a research program was undertaken at the University of Science and Technology AGH UST to investigate the effects of low-frequency vibration on selected parameters of hepatic profile of human blood. Cyclic fluctuations of bone loading were induced by the applied harmonic vibration 3.5 Hz and amplitude 0.004 m. The experiments utilizing two vibrating platforms were performed in the Laboratory of Structural Acoustics and Biomedical Engineering AGH-UST. The applied vibrations were harmless and not annoying, in accordance with the standard PN-EN ISO 130901-1, 1998. 23 women volunteers had 19 sessions on subsequent working days, at the same time of day. during the tests the participants remained in the standing position, passive. The main hypothesis has it that short-term low-frequency vibration exposure might bring about the changes of the hepatic profile of blood, including: bilirubin (BILIRUBIN), alkaline phosphatase (Alp), alanine aminotransferase (ALT), aspartate aminotransferase (AST) and albumin (ALBUMIN) levels. Research data indicate the low-frequency vibrations exposure produces statistically significant decrease of

  13. Vibration sensibility testing in the workplace. Day-to-day reliability.

    PubMed

    Rosecrance, J C; Cook, T M; Satre, D L; Goode, J D; Schroder, M J

    1994-09-01

    Loss of vibration sensibility has been suggested as an early indicator of peripheral compression neuropathy, including carpal tunnel syndrome. Although vibration sensibility has been used frequently to evaluate carpal tunnel syndrome, the day-to-day reliability of vibration measurements in an industrial population measured at the workplace has not been assessed. Vibration sensibility testing was performed at the university ergonomics laboratory on 50 volunteers (100 hands) and at a newspaper company on 50 workers (100 hands). Vibration perception and disappearance thresholds were measured on two occasions separated by 3 to 5 days. Student's t tests indicated no significant differences between the first and second tests or between the two groups. Pearson product-moment correlations for test-retest reliability were lower in the industry group but were relatively high despite the less than optimal testing conditions. Our findings suggest that vibration sensibility measurements are reliable from day to day not only in the laboratory but also in the workplace.

  14. Nonlinear effects contributing to hand-stopping tones in a horn.

    PubMed

    Ebihara, Takayasu; Yoshikawa, Shigeru

    2013-05-01

    Hand stopping is a technique for playing the French horn while closing the bell relatively tightly using the right hand. The resulting timbre is called "penetrating" and "metallic." The effect of hand stopping on the horn input impedance has been studied, but the tone quality has hardly ever been considered. In the present paper, the dominant physical cause of the stopped-tone quality is discussed in detail. Numerical calculations of the transmission function of the stopped-horn model and the measurements of both sound pressure and wall vibration in hand stopping are carried out. They strongly suggest that the metallicness of the stopped tone is characterized by the generation of higher harmonics extending over 10 kHz due to the rapidly corrugating waveform and that the associated wall vibration on the bell may be responsible for this higher harmonic generation. However, excitation experiments and immobilization experiments performed to elucidate the relationship between sound radiation and wall vibration deny their correlation. Instead, the measurement result of the mouthpiece pressure in hand stopping suggests that minute wave corrugations peculiar to the metallic stopped tones are probably formed by nonlinear sound propagation along the bore.

  15. Role of Kv4.3 in Vibration-Induced Muscle Pain in the Rat.

    PubMed

    Conner, Lindsay B; Alvarez, Pedro; Bogen, Oliver; Levine, Jon D

    2016-04-01

    We hypothesized that changes in the expression of voltage-gated potassium channel (Kv) 4.3 contribute to the mechanical hyperalgesia induced by vibration injury, in a rodent model for hand-arm vibration syndrome in humans. Here we show that the exposure of the gastrocnemius muscle to vibration injury induces muscle hyperalgesia that is accompanied by a significant downregulation of Kv4.3 in affected sensory nerve fibers in dorsal root ganglia. We additionally show that the intrathecal administration of antisense oligonucleotides for Kv4.3 messenger RNA itself induces muscle hyperalgesia in the rat. Our results suggest that attenuation in the expression of Kv4.3 may contribute to neuropathic pain in people affected by hand-arm vibration syndrome. Our findings establish Kv4.3 as a potential molecular target for the treatment of hand-arm vibration syndrome. Copyright © 2016 American Pain Society. Published by Elsevier Inc. All rights reserved.

  16. Effects of waterproof covering on hand immersion tests using water at 10 degrees C, 12 degrees C and 15 degrees C for diagnosis of hand-arm vibration syndrome.

    PubMed

    Suizu, K; Harada, N

    2005-05-01

    To compare effects of waterproof covering on finger skin temperature (FST) and subjective hand pain during immersion tests using cold water at 10 degrees C, 12 degrees C and 15 degrees C. In the (Draft International Standard) of the International Organization for Standardization (ISO/DIS 14835-1), a water temperature of 12 degrees C and use of water covering are proposed. Six healthy male subjects took part in the immersion tests and immersed both hands into water at 10 degrees C, 12 degrees C and 15 degrees C for 5 min, repeatedly, with waterproof covering (polyethylene gloves) or without (bare hands). The FST data from middle fingers and subjective pain scores for hand pain were analyzed. Furthermore, the test with water at 12 degrees C was repeated to assess the repeatability of the test. The glove and water temperature factors for FST were significant at every minute from 1 min during immersion up to 2 min after recovery, showing higher values for waterproof covering than for bare hands and showing lowest values for water temperature of 10 degrees C and highest for 15 degrees C. The glove and water temperature factors for subjective pain score were significant at the 1-min and 2-min points during immersion, showing lower scores for waterproof covering than for bare hands and showing highest scores for water temperature of 10 degrees C and lowest for 15 degrees C. The results of the first and second tests using water of 12 degrees C showed no systematic difference in FST and hand pain between the tests, with a few exceptions. Subjective pain during the cold immersion test with polyethylene gloves and water at 12 degrees C can be reduced, while the differences in FST between water temperatures of 10 degrees C and 12 degrees C were small or not apparent at some points during immersion and recovery. The test also seems to be suitable for repeatability. Further investigation on hand-arm vibration syndrome (HAVS) patients to validate the use of the immersion test

  17. Topographic analysis of the skull vibration-induced nystagmus test with piezoelectric accelerometers and force sensors.

    PubMed

    Dumas, Georges; Lion, Alexis; Perrin, Philippe; Ouedraogo, Evariste; Schmerber, Sébastien

    2016-03-23

    Vibration-induced nystagmus is elicited by skull or posterior cervical muscle stimulations in patients with vestibular diseases. Skull vibrations delivered by the skull vibration-induced nystagmus test are known to stimulate the inner ear structures directly. This study aimed to measure the vibration transfer at different cranium locations and posterior cervical regions to contribute toward stimulus topographic optimization (experiment 1) and to determine the force applied on the skull with a hand-held vibrator to study the test reproducibility and provide recommendations for good clinical practices (experiment 2). In experiment 1, a 100 Hz hand-held vibrator was applied on the skull (vertex, mastoids) and posterior cervical muscles in 11 healthy participants. Vibration transfer was measured by piezoelectric sensors. In experiment 2, the vibrator was applied 30 times by two experimenters with dominant and nondominant hands on a mannequin equipped to measure the force. Experiment 1 showed that after unilateral mastoid vibratory stimulation, the signal transfer was higher when recorded on the contralateral mastoid than on the vertex or posterior cervical muscles (P<0.001). No difference was observed between the different vibratory locations when vibration transfer was measured on vertex and posterior cervical muscles. Experiment 2 showed that the force applied to the mannequin varied according to the experimenters and the handedness, higher forces being observed with the most experienced experimenter and with the dominant hand (10.3 ± 1.0 and 7.8 ± 2.9 N, respectively). The variation ranged from 9.8 to 29.4% within the same experimenter. Bone transcranial vibration transfer is more efficient from one mastoid to the other mastoid than other anatomical sites. The mastoid is therefore the optimal site for skull vibration-induced nystagmus test in patients with unilateral vestibular lesions and enables a stronger stimulation of the healthy side. In clinical practice

  18. Hand held phase-shifting diffraction Moire interferometer

    DOEpatents

    Deason, V.A.; Ward, M.B.

    1994-09-20

    An interferometer is described in which a coherent beam of light is generated within a remote case and transmitted to a hand held unit tethered to said remote case, said hand held unit having optical elements for directing a pair of mutually coherent collimated laser beams at a diffraction grating. Data from the secondary or diffracted beams are then transmitted to a separate video and data acquisition system for recording and analysis for load induced deformation or for identification purposes. Means are also provided for shifting the phase of one incident beam relative to the other incident beam and being controlled from within said remote case. 4 figs.

  19. Hand held phase-shifting diffraction moire interferometer

    DOEpatents

    Deason, Vance A.; Ward, Michael B.

    1994-01-01

    An interferometer in which a coherent beam of light is generated within a remote case and transmitted to a hand held unit tethered to said remote case, said hand held unit having optical elements for directing a pair of mutually coherent collimated laser beams at a diffraction grating. Data from the secondary or diffracted beams are then transmitted to a separate video and data acquisition system for recording and analysis for load induced deformation or for identification purposes. Means are also provided for shifting the phase of one incident beam relative to the other incident beam and being controlled from within said remote case.

  20. Design of a candidate vibrational signal for mating disruption against the glassy-winged sharpshooter, Homalodisca Vitripennis

    USDA-ARS?s Scientific Manuscript database

    The glassy-winged sharpshooter (GWSS), Homalodisca vitripennis, is an important pest of grapevines due to its ability to transmit Xylella fastidiosa, the causal agent of Pierce’s disease. GWSS mating communication is based on vibrational signals; therefore, vibrational mating disruption could be an ...

  1. The effects of repetitive vibration on sensorineural function: biomarkers of sensorineural injury in an animal model of metabolic syndrome

    PubMed Central

    Kiedrowski, Megan; Waugh, Stacey; Miller, Roger; Johnson, Claud; Krajnak, Kristine

    2016-01-01

    Exposure to hand-transmitted vibration in the work-place can result in the loss of sensation and pain in workers. These effects may be exacerbated by pre-existing conditions such as diabetes or the presence of primary Raynaud's phenomena. The goal of these studies was to use an established model of vibration-induced injury in Zucker rats. Lean Zucker rats have a normal metabolic profile, while obese Zucker rats display symptoms of metabolic disorder or Type II diabetes. This study examined the effects of vibration in obese and lean rats. Zucker rats were exposed to 4 h of vibration for 10 consecutive days at a frequency of 125 Hz and acceleration of 49 m/s2 for 10 consecutive days. Sensory function was checked using transcutaneous electrical stimulation on days 1, 5 and 9 of the exposure. Once the study was complete the ventral tail nerves, dorsal root ganglia and spinal cord were dissected, and levels of various transcripts involved in sensorineural dysfunction were measured. Sensorineural dysfunction was assessed using transcutaneous electrical stimulation. Obese Zucker rats displayed very few changes in sensorineural function. However they did display significant changes in transcript levels for factors involved in synapse formation, peripheral nerve remodeling, and inflammation. The changes in transcript levels suggested that obese Zucker rats had some level of sensory nerve injury prior to exposure, and that exposure to vibration activated pathways involved in injury and re-innervation. PMID:26433044

  2. New regression model for predicting hand-arm vibration (HAV) of Malaysian Army (MA) three-tonne truck steering wheels.

    PubMed

    Aziz, Shamsul Akmar Ab; Nuawi, Mohd Zaki; Nor, Mohd Jailani Mohd

    2015-01-01

    The objective of this study was to present a new method for determination of hand-arm vibration (HAV) in Malaysian Army (MA) three-tonne truck steering wheels based on changes in vehicle speed using regression model and the statistical analysis method known as Integrated Kurtosis-Based Algorithm for Z-Notch Filter Technique Vibro (I-kaz Vibro). The test was conducted for two different road conditions, tarmac and dirt roads. HAV exposure was measured using a Brüel & Kjær Type 3649 vibration analyzer, which is capable of recording HAV exposures from steering wheels. The data was analyzed using I-kaz Vibro to determine the HAV values in relation to varying speeds of a truck and to determine the degree of data scattering for HAV data signals. Based on the results obtained, HAV experienced by drivers can be determined using the daily vibration exposure A(8), I-kaz Vibro coefficient (Ƶ(v)(∞)), and the I-kaz Vibro display. The I-kaz Vibro displays also showed greater scatterings, indicating that the values of Ƶ(v)(∞) and A(8) were increasing. Prediction of HAV exposure was done using the developed regression model and graphical representations of Ƶ(v)(∞). The results of the regression model showed that Ƶ(v)(∞) increased when the vehicle speed and HAV exposure increased. For model validation, predicted and measured noise exposures were compared, and high coefficient of correlation (R(2)) values were obtained, indicating that good agreement was obtained between them. By using the developed regression model, we can easily predict HAV exposure from steering wheels for HAV exposure monitoring.

  3. Vibration on board and health effects.

    PubMed

    Jensen, Anker; Jepsen, Jørgen Riis

    2014-01-01

    There is only limited knowledge of the exposure to vibrations of ships' crews and their risk of vibration-induced health effects. Exposure to hand-arm vibrations from the use of vibrating tools at sea does not differ from that in the land-based trades. However, in contrast to most other work places, seafarers are also exposed to vibrations to the feet when standing on vibrating surfaces on board. Anecdotal reports have related the development of "white feet" to local exposure to vibration, e.g. in mining, but this connection has not been investigated in the maritime setting. As known from studies of the health consequences of whole body vibrations in land-transportation, such exposure at sea may affect ships' passengers and crews. While the relation of back disorders to high levels of whole body vibration has been demonstrated among e.g. tractor drivers, there are no reported epidemiological evidence for such relation among seafarers except for fishermen, who, however, are also exposed to additional recognised physical risk factors at work. The assessment and reduction of vibrations by naval architects relates to technical implications of this impact for the ships' construction, but has limited value for the estimation of health risks because they express the vibration intensity differently that it is done in a medical context.

  4. A two scale modeling and computational framework for vibration-induced Raynaud syndrome.

    PubMed

    Hua, Yue; Lemerle, Pierre; Ganghoffer, Jean-François

    2017-07-01

    Hand-Arm Vibration syndrome (HAVS), usually caused by long-term use of hand-held power tools, can in certain manifestations alter the peripheral blood circulation in the hand-arm region. HAVS typically occurs after exposure to cold, causing an abnormally strong vasoconstriction of blood vessels. A pathoanatomical mechanism suggests that a reduction of the lumen of the blood vessels in VWF (Vibration White Finger) subjects, due to either hypertrophy or thickening of the vessel wall, may be at the origin of the disease. However, the direct and indirect effects of the load of the hand-held tools on the structure of blood vessels remain controversial:.one hypothesis is the mechanical action of vibration on the local acral dysregulation and/or on the vessel histomorphological modifications. Another hypothesis is the participation of the sympathetic nervous system to this dysregulation. In this paper, we assume the modifications as mechanobiological growth and the load-effect relationship may be interpreted as directly or indirectly induced. This work is the first attempt to model the effect of vibration through soft tissues onto the distal capillaries, addressing the double paradigm of multi space-time scales, i.e. low period vibration versus high time constant of the growth phenomenon as well as vibrations propagating in the macroscopic tissue including the microscopic capillary structures subjected to a pathological microstructural evolution. The objective is to lay down the theoretical basis of growth modeling for the small distal artery, with the ability to predict the geometrical and structural changes of the arterial walls caused by vibration exposure. We adopt the key idea of splitting the problem into one global vibration problem at the macroscopic scale and one local growth problem at the micro level. The macroscopic hyperelastic viscous dynamic model of the fingertip cross-section is validated by fitting experimental data. It is then used in steady

  5. Optimization of new magnetorheological fluid mount for vibration control of start/stop engine mode

    NASA Astrophysics Data System (ADS)

    Chung, Jye Ung; Phu, Do Xuan; Choi, Seung-Bok

    2015-04-01

    The technologies related to saving energy/or green vehicles are actively researched. In this tendency, the problem for reducing exhausted gas is in development with various ways. Those efforts are directly related to the operation of engine which emits exhausted gas. The auto start/stop of vehicle engine when a vehicle stop at road is currently as a main stream of vehicle industry resulting in reducing exhausted gas. However, this technology automatically turns on and off engine frequently. This motion induces vehicle engine to transmit vibration of engine which has large displacement, and torsional impact to chassis. These vibrations causing uncomfortable feeling to passengers are transmitted through the steering wheel and the gear knob. In this work, in order to resolve this vibration issue, a new proposed magnetorheological (MR) fluid based engine mount (MR mount in short) is presented. The proposed MR mount is designed to satisfy large damping force in various frequency ranges. It is shown that the proposed mount can have large damping force and large force ratio which is enough to control unwanted vibrations of engine start/stop mode.

  6. Effect of Tendon Vibration on Hemiparetic Arm Stability in Unstable Workspaces.

    PubMed

    Conrad, Megan O; Gadhoke, Bani; Scheidt, Robert A; Schmit, Brian D

    2015-01-01

    Sensory stimulation of wrist musculature can enhance stability in the proximal arm and may be a useful therapy aimed at improving arm control post-stroke. Specifically, our prior research indicates tendon vibration can enhance stability during point-to-point arm movements and in tracking tasks. The goal of the present study was to investigate the influence of forearm tendon vibration on endpoint stability, measured at the hand, immediately following forward arm movements in an unstable environment. Both proximal and distal workspaces were tested. Ten hemiparetic stroke subjects and 5 healthy controls made forward arm movements while grasping the handle of a two-joint robotic arm. At the end of each movement, the robot applied destabilizing forces. During some trials, 70 Hz vibration was applied to the forearm flexor muscle tendons. 70 Hz was used as the stimulus frequency as it lies within the range of optimal frequencies that activate the muscle spindles at the highest response rate. Endpoint position, velocity, muscle activity and grip force data were compared before, during and after vibration. Stability at the endpoint was quantified as the magnitude of oscillation about the target position, calculated from the power of the tangential velocity data. Prior to vibration, subjects produced unstable, oscillating hand movements about the target location due to the applied force field. Stability increased during vibration, as evidenced by decreased oscillation in hand tangential velocity.

  7. Effect of Tendon Vibration on Hemiparetic Arm Stability in Unstable Workspaces

    PubMed Central

    Conrad, Megan O.; Gadhoke, Bani; Scheidt, Robert A.; Schmit, Brian D.

    2015-01-01

    Sensory stimulation of wrist musculature can enhance stability in the proximal arm and may be a useful therapy aimed at improving arm control post-stroke. Specifically, our prior research indicates tendon vibration can enhance stability during point-to-point arm movements and in tracking tasks. The goal of the present study was to investigate the influence of forearm tendon vibration on endpoint stability, measured at the hand, immediately following forward arm movements in an unstable environment. Both proximal and distal workspaces were tested. Ten hemiparetic stroke subjects and 5 healthy controls made forward arm movements while grasping the handle of a two-joint robotic arm. At the end of each movement, the robot applied destabilizing forces. During some trials, 70 Hz vibration was applied to the forearm flexor muscle tendons. 70 Hz was used as the stimulus frequency as it lies within the range of optimal frequencies that activate the muscle spindles at the highest response rate. Endpoint position, velocity, muscle activity and grip force data were compared before, during and after vibration. Stability at the endpoint was quantified as the magnitude of oscillation about the target position, calculated from the power of the tangential velocity data. Prior to vibration, subjects produced unstable, oscillating hand movements about the target location due to the applied force field. Stability increased during vibration, as evidenced by decreased oscillation in hand tangential velocity. PMID:26633892

  8. The effects of whole body vibration on EMG activity of the upper extremity muscles in static modified push up position.

    PubMed

    Ashnagar, Zinat; Shadmehr, Azadeh; Hadian, Mohammadreza; Talebian, Saeed; Jalaei, Shohreh

    2016-08-10

    Whole Body Vibration (WBV) has been reported to change neuromuscular activity which indirectly assessed by electromyography (EMG). Although researches regarding the influence of WBV on EMG activity of the upper extremity muscles are in their infancy, contradictory findings have been reported as a result of dissimilar protocols. The purpose of this study was to investigate the effects of WBV on electromyography (EMG) activity of upper extremity muscles in static modified push up position. Forty recreationally active females were randomly assigned in WBV and control groups. Participants in WBV group received 5 sets of 30 seconds vibration at 5 mm (peak to peak) and 30 Hz by using vibratory platform. No vibration stimulus was used in the control group. Surface EMG was recorded from Upper Trapezius (UT), Serratus Anterior (SA), Biceps Brachii (BB) and Triceps Brachii (TB) muscles before, during and after the vibration protocol while the subjects maintained the static modified push up position. EMG signals were expressed as root mean square (EMGrms) and normalized by maximum voluntary exertion (MVE). EMGrms activity of the studied muscles increased significantly during the vibration protocol in the WBV group comparing to the control group (P ≤ 0.05). The results indicated that vibration stimulus transmitting via hands increased muscle activity of UT, SA, BB and TB muscles by an average of 206%, 60%, 106% and 120%, respectively, comparing to pre vibration values. These findings suggest that short exposure to the WBV could increase the EMGrms activity of the upper extremity muscles in the static modified push-up position. However, more sessions of WBV application require for a proper judgment.

  9. The sensitivity and specificity of thermometry and plethysmography in the assessment of hand-arm vibration syndrome.

    PubMed

    Thompson, Aaron; House, Ron; Manno, Michael

    2008-05-01

    Finger plethysmography and thermometry are objective measures used to assess the vascular aspect of hand-arm vibration syndrome (HAVS). Research to date shows poor correlation between these tests and Stockholm Workshop Scale (SWS) vascular stage. Clinicians, researchers and compensation boards require objective means to diagnose and quantify HAVS. To define the specificity and sensitivity of thermometry and plethysmography using the SWS as the reference criterion. A secondary goal was to consider cut points for the tests optimizing sensitivity and specificity. A cross-sectional analysis was conducted on HAVS patients seen at an occupational medicine specialty clinic. Plethysmography and thermometry were analyzed using SWS vascular stage as the outcome variable. Logistic regression controlled for age, smoking and time since last vibration exposure and use of vasoactive medications. The sensitivity and specificity of the combined tests were calculated using varying cut points. A total of 139 patients consented to participate in the study. Plethysmography stage 1 or greater showed the highest sensitivity (sensitivity 94% and specificity 15%). Specificity was optimized combining plethysmography stage 3 and thermometry stage 3 (specificity 98% and sensitivity 23%). Maximal diagnostic accuracy was achieved by plethysmography alone setting the criteria for a positive test as being stage 1 or greater (70%). Neither plethysmography nor thermometry either alone or in combination demonstrated sufficient sensitivity and specificity to serve as an objective correlate for SWS vascular stage. All combinations of plethysmography and thermometry showed a lower specificity than sensitivity indicating that the SWS may be less sensitive in detecting vascular pathology than the objective tests.

  10. Quantification of mouse in vivo whole-body vibration amplitude from motion-blur using x-ray imaging.

    PubMed

    Hu, Zhengyi; Welch, Ian; Yuan, Xunhua; Pollmann, Steven I; Nikolov, Hristo N; Holdsworth, David W

    2015-08-21

    Musculoskeletal effects of whole-body vibration on animals and humans have become an intensely studied topic recently, due to the potential of applying this method as a non-pharmacological therapy for strengthening bones. It is relatively easy to quantify the transmission of whole-body mechanical vibration through the human skeletal system using accelerometers. However, this is not the case for small-animal pre-clinical studies because currently available accelerometers have a large mass, relative to the mass of the animals, which causes the accelerometers themselves to affect the way vibration is transmitted. Additionally, live animals do not typically remain motionless for long periods, unless they are anesthetized, and they are required to maintain a static standing posture during these studies. These challenges provide the motivation for the development of a method to quantify vibrational transmission in small animals. We present a novel imaging technique to quantify whole-body vibration transmission in small animals using 280 μm diameter tungsten carbide beads implanted into the hind limbs of mice. Employing time-exposure digital x-ray imaging, vibrational amplitude is quantified based on the blurring of the implanted beads caused by the vibrational motion. Our in vivo results have shown this technique is capable of measuring vibration amplitudes as small as 0.1 mm, with precision as small as  ±10 μm, allowing us to distinguish differences in the transmitted vibration at different locations on the hindlimbs of mice.

  11. Quantification of mouse in vivo whole-body vibration amplitude from motion-blur using x-ray imaging

    NASA Astrophysics Data System (ADS)

    Hu, Zhengyi; Welch, Ian; Yuan, Xunhua; Pollmann, Steven I.; Nikolov, Hristo N.; Holdsworth, David W.

    2015-08-01

    Musculoskeletal effects of whole-body vibration on animals and humans have become an intensely studied topic recently, due to the potential of applying this method as a non-pharmacological therapy for strengthening bones. It is relatively easy to quantify the transmission of whole-body mechanical vibration through the human skeletal system using accelerometers. However, this is not the case for small-animal pre-clinical studies because currently available accelerometers have a large mass, relative to the mass of the animals, which causes the accelerometers themselves to affect the way vibration is transmitted. Additionally, live animals do not typically remain motionless for long periods, unless they are anesthetized, and they are required to maintain a static standing posture during these studies. These challenges provide the motivation for the development of a method to quantify vibrational transmission in small animals. We present a novel imaging technique to quantify whole-body vibration transmission in small animals using 280 μm diameter tungsten carbide beads implanted into the hind limbs of mice. Employing time-exposure digital x-ray imaging, vibrational amplitude is quantified based on the blurring of the implanted beads caused by the vibrational motion. Our in vivo results have shown this technique is capable of measuring vibration amplitudes as small as 0.1 mm, with precision as small as  ±10 μm, allowing us to distinguish differences in the transmitted vibration at different locations on the hindlimbs of mice.

  12. Surface-Enhanced Impulsive Coherent Vibrational Spectroscopy

    PubMed Central

    Du, Juan; Harra, Juha; Virkki, Matti; Mäkelä, Jyrki M.; Leng, Yuxin; Kauranen, Martti; Kobayashi, Takayoshi

    2016-01-01

    Surface-enhanced Raman spectroscopy (SERS) has attracted a lot of attention in molecular sensing because of the remarkable ability of plasmonic metal nanostructures to enhance the weak Raman scattering process. On the other hand, coherent vibrational spectroscopy triggered by impulsive excitation using ultrafast laser pulses provides complete information about the temporal evolution of molecular vibrations, allowing dynamical processes in molecular systems to be followed in “real time”. Here, we combine these two concepts and demonstrate surface-enhanced impulsive vibrational spectroscopy. The vibrational modes of the ground and excited states of poly[2-methoxy-5-(2-ethylhexyloxy)−1,4-phenylenevinylene] (MEH-PPV), spin-coated on a substrate covered with monodisperse silver nanoparticles, are impulsively excited with a sub-10 fs pump pulse and characterized with a delayed broad-band probe pulse. The maximum enhancement in the spectrally and temporally resolved vibrational signatures averaged over the whole sample is about 4.6, while the real-time information about the instantaneous vibrational amplitude together with the initial vibrational phase is preserved. The phase is essential to determine the vibrational contributions from the ground and excited states. PMID:27812020

  13. Assessment of two alternative standardised tests for the vascular component of the hand-arm vibration syndrome (HAVS).

    PubMed

    Ye, Ying; Griffin, Michael J

    2016-10-01

    Vibration-induced white finger (VWF) is the vascular component of the hand-arm vibration syndrome (HAVS). Two tests have been standardised so as to assist the diagnosis of VWF: the measurement of finger rewarming times and the measurement of finger systolic blood pressures (FSBPs). This study investigates whether the two tests distinguish between fingers with and without symptoms of whiteness and compares individual results between the two test methods. In 60 men reporting symptoms of the HAVS, the times for their fingers to rewarm by 4°C (after immersion in 15°C water for 5 min) and FSBPs at 30°C, 15°C and 10°C were measured on the same day. There were significant increases in finger rewarming times and significant reductions in FSBPs at both 15°C and 10°C in fingers reported to suffer blanching. The FSBPs had sensitivities and specificities >90%, whereas the finger rewarming test had a sensitivity of 77% and a specificity of 79%. Fingers having longer rewarming times had lower FSBPs at both temperatures. The findings suggest that, when the test conditions are controlled according to the relevant standard, finger rewarming times and FSBPs can provide useful information for the diagnosis of VWF, although FSBPs are more sensitive and more specific. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. Imaging acoustic vibrations in an ear model using spectrally encoded interferometry

    NASA Astrophysics Data System (ADS)

    Grechin, Sveta; Yelin, Dvir

    2018-01-01

    Imaging vibrational patterns of the tympanic membrane would allow an accurate measurement of its mechanical properties and provide early diagnosis of various hearing disorders. Various optical technologies have been suggested to address this challenge and demonstrated in vitro using point scanning and full-field interferometry. Spectrally encoded imaging has been previously demonstrated capable of imaging tissue acoustic vibrations with high spatial resolution, including two-dimensional phase and amplitude mapping. In this work, we demonstrate a compact optical apparatus for imaging acoustic vibrations that could be incorporated into a commercially available digital otoscope. By transmitting harmonic sound waves through the otoscope insufflation port and analyzing the spectral interferograms using custom-built software, we demonstrate high-resolution vibration imaging of a circular rubber membrane within an ear model.

  15. Role of Kv 4.3 in vibration-induced muscle pain in the rat

    PubMed Central

    Conner, Lindsay; Alvarez, Pedro; Bogen, Oliver; Levine, Jon D.

    2015-01-01

    We hypothesized that changes in the expression of Kv4.3 contribute to the mechanical hyperalgesia induced by vibration injury, a rodent model for hand-arm vibration syndrome in humans. Here we show that the exposure of the gastrocnemius muscle to vibration injury induces muscle hyperalgesia that is accompanied by a significant down-regulation of Kv4.3 in affected sensory nerve fibers in dorsal root ganglia (DRG). We additionally demonstrate that the intrathecal administration of antisense oligonucleotides for Kv4.3 mRNA itself induces muscle hyperalgesia in the rat. Our results suggest that attenuation in the expression of Kv4.3 may contribute to neuropathic pain in people affected by hand-arm vibration syndrome. PMID:26721612

  16. Vibration Transmission through Bearings with Application to Gearboxes

    NASA Technical Reports Server (NTRS)

    Fleming, David P.

    2007-01-01

    Cabin noise has become a major concern to manufacturers and users of helicopters. Gear noise is the largest part of this unwanted sound. The crucial noise path is generally considered to be from the gears through the gear-supporting shafts and bearings into the gearbox case, and from there either through the gearbox mounts or the surrounding air to the helicopter cabin. If the noise, that is, the gear and shaft vibration, can be prevented from traveling through the gearbox bearings, then the noise cannot make its way into the helicopter cabin. Thus the vibration-transmitting properties of bearings are of paramount importance. This paper surveys the literature concerning evaluation of properties for the types of bearings used in helicopter gearboxes. A simple model is proposed to evaluate vibration transmission, using measured or calculated bearing stiffness and damping. Less-commonly used types of gearbox bearings (e.g., fluid film) are evaluated for their potential in reducing vibration transmission.

  17. Deviations of frequency and the mode of vibration of commercially available whole-body vibration training devices.

    PubMed

    Kaeding, T S

    2015-06-01

    Research in the field of whole body vibration (WBV) training and the use of it in practice might be hindered by the fact that WBV training devices generate and transmit frequencies and/or modes of vibration which are different to preset adjustments. This research project shall clarify how exact WBV devices apply the by manufacturer information promised preset frequency and mode of vibration. Nine professional devices for WBV training were tested by means of a tri-axial accelerometer. The accelerations of each device were recorded under different settings with a tri-axial accelerometer. Beneath the measurement of different combinations of preset frequency and amplitude the repeatability across 3 successive measurements with the same preset conditions and one measurement under loaded condition were carried out. With 3 exceptions (both Board 3000 & srt medical PRO) we did not find noteworthy divergences between preset and actual applied frequencies. In these 3 devices we found divergences near -25%. Loading the devices did not affect the applied frequency or mode of vibration. There were no important divergences measurable for the applied frequency and mode of vibration regarding repeatability. The results of our measurements cannot be generalized as we only measured one respectively at most two devices of one model in terms of a random sample. Based on these results we strongly recommend that user in practice and research should analyse their WBV training devices regarding applied frequency and mode of vibration.

  18. Vibration Penalty Estimates for Indoor Annoyance Caused by Sonic Boom

    NASA Technical Reports Server (NTRS)

    Rathsam, Jonathan; Klos, Jacob

    2016-01-01

    Commercial supersonic flight is currently forbidden over land because sonic booms have historically caused unacceptable annoyance levels in overflown communities. NASA is providing data and expertise to noise regulators as they consider relaxing the ban for future quiet supersonic aircraft. One key objective is a predictive model for indoor annoyance based on factors such as noise and indoor vibration levels. The current study quantified the increment in indoor sonic boom annoyance when sonic booms can be felt directly through structural vibrations in addition to being heard. A shaker mounted below each chair in the sonic boom simulator emulated vibrations transmitting through the structure to that chair. The vibration amplitudes were determined from numeric models of a large range of residential structures excited by the same sonic boom waveforms used in the experiment. The analysis yielded vibration penalties, which are the increments in sound level needed to increase annoyance as much as the vibration does. For sonic booms at acoustic levels from 75 to 84 dB Perceived Level, vibration signals with lower amplitudes (+1 sigma) yielded penalties from 0 to 5 dB, and vibration signals with higher amplitudes (+3 sigma) yielded penalties from 6 to 10 dB.

  19. Shaft instantaneous angular speed for blade vibration in rotating machine

    NASA Astrophysics Data System (ADS)

    Gubran, Ahmed A.; Sinha, Jyoti K.

    2014-02-01

    Reliable blade health monitoring (BHM) in rotating machines like steam turbines and gas turbines, is a topic of research since decades to reduce machine down time, maintenance costs and to maintain the overall safety. Transverse blade vibration is often transmitted to the shaft as torsional vibration. The shaft instantaneous angular speed (IAS) is nothing but the representing the shaft torsional vibration. Hence the shaft IAS has been extracted from the measured encoder data during machine run-up to understand the blade vibration and to explore the possibility of reliable assessment of blade health. A number of experiments on an experimental rig with a bladed disk were conducted with healthy but mistuned blades and with different faults simulation in the blades. The measured shaft torsional vibration shows a distinct difference between the healthy and the faulty blade conditions. Hence, the observations are useful for the BHM in future. The paper presents the experimental setup, simulation of blade faults, experiments conducted, observations and results.

  20. Research on the design of fixture for motor vibration test

    NASA Astrophysics Data System (ADS)

    Shen, W. X.; Ma, W. S.; Zhang, L. W.

    2018-03-01

    The vibration reliability of the new energy automobile motor plays a very important role in driving safety, so it is very important to test the vibration durability of the motor. In the vibration test process, the fixture is very important, simulated road spectrum signal vibration can be transmitted without distortion to the motor through the fixture, fixture design directly affect the result of vibration endurance test. On the basis of new energy electric vehicle motor concrete structure, Two fixture design and fixture installation schemes for lateral cantilever type and base bearing type are put forward in this article, the selection of material, weighting process, middle alignment process and manufacturing process are summarized.The modal analysis and frequency response calculation of the fixture are carried out in this design, combine with influence caused by fixture height and structure profile on response frequency, the response frequency of each order of the fixture is calculated, then ultimately achieve the purpose of guiding the design.

  1. Evaluation of haptic interfaces for simulation of drill vibration in virtual temporal bone surgery.

    PubMed

    Ghasemloonia, Ahmad; Baxandall, Shalese; Zareinia, Kourosh; Lui, Justin T; Dort, Joseph C; Sutherland, Garnette R; Chan, Sonny

    2016-11-01

    Surgical training is evolving from an observership model towards a new paradigm that includes virtual-reality (VR) simulation. In otolaryngology, temporal bone dissection has become intimately linked with VR simulation as the complexity of anatomy demands a high level of surgeon aptitude and confidence. While an adequate 3D visualization of the surgical site is available in current simulators, the force feedback rendered during haptic interaction does not convey vibrations. This lack of vibration rendering limits the simulation fidelity of a surgical drill such as that used in temporal bone dissection. In order to develop an immersive simulation platform capable of haptic force and vibration feedback, the efficacy of hand controllers for rendering vibration in different drilling circumstances needs to be investigated. In this study, the vibration rendering ability of four different haptic hand controllers were analyzed and compared to find the best commercial haptic hand controller. A test-rig was developed to record vibrations encountered during temporal bone dissection and a software was written to render the recorded signals without adding hardware to the system. An accelerometer mounted on the end-effector of each device recorded the rendered vibration signals. The newly recorded vibration signal was compared with the input signal in both time and frequency domains by coherence and cross correlation analyses to quantitatively measure the fidelity of these devices in terms of rendering vibrotactile drilling feedback in different drilling conditions. This method can be used to assess the vibration rendering ability in VR simulation systems and selection of ideal haptic devices. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. SVMs for Vibration-Based Terrain Classification

    NASA Astrophysics Data System (ADS)

    Weiss, Christian; Stark, Matthias; Zell, Andreas

    When an outdoor mobile robot traverses different types of ground surfaces, different types of vibrations are induced in the body of the robot. These vibrations can be used to learn a discrimination between different surfaces and to classify the current terrain. Recently, we presented a method that uses Support Vector Machines for classification, and we showed results on data collected with a hand-pulled cart. In this paper, we show that our approach also works well on an outdoor robot. Furthermore, we more closely investigate in which direction the vibration should be measured. Finally, we present a simple but effective method to improve the classification by combining measurements taken in multiple directions.

  3. Application of a sparse representation method using K-SVD to data compression of experimental ambient vibration data for SHM

    NASA Astrophysics Data System (ADS)

    Noh, Hae Young; Kiremidjian, Anne S.

    2011-04-01

    This paper introduces a data compression method using the K-SVD algorithm and its application to experimental ambient vibration data for structural health monitoring purposes. Because many damage diagnosis algorithms that use system identification require vibration measurements of multiple locations, it is necessary to transmit long threads of data. In wireless sensor networks for structural health monitoring, however, data transmission is often a major source of battery consumption. Therefore, reducing the amount of data to transmit can significantly lengthen the battery life and reduce maintenance cost. The K-SVD algorithm was originally developed in information theory for sparse signal representation. This algorithm creates an optimal over-complete set of bases, referred to as a dictionary, using singular value decomposition (SVD) and represents the data as sparse linear combinations of these bases using the orthogonal matching pursuit (OMP) algorithm. Since ambient vibration data are stationary, we can segment them and represent each segment sparsely. Then only the dictionary and the sparse vectors of the coefficients need to be transmitted wirelessly for restoration of the original data. We applied this method to ambient vibration data measured from a four-story steel moment resisting frame. The results show that the method can compress the data efficiently and restore the data with very little error.

  4. Possibility for new PolyCO imaging: stroboscopic imaging based on vibrating capillary optics

    NASA Astrophysics Data System (ADS)

    Liedl, A.; Dabagov, S. B.; Della Ventura, G.; Hampai, D.; Polese, C.

    2015-08-01

    Polycapillary lenses are well known optical devices for radiation and charged particles. These lenses consist of thousands channels through which the signal is transmitted by total external reflection phenomenon. Their application have made possible technical improvements in different fields such as imaging, fluorescence analysis, channeling studies etc. In particular, the application of this optics coupled with conventional sources such as X-ray tubes has opened a new season for potential applications of desktop instrumentations. For instance, the usage of such lenses has enhanced the spatial coherence and the brilliance over the sample allowing better resolution and contrast for imaging purposes. In addiction, improved focusing power and confocal configuration of other lenses has improved the resolution, from both the energy and the spatial points of view, in fluorescence mapping. A recent work has addressed the behavior of the transmitted radiation through a single capillary in vibrating regime. In this work a test of using a vibrating capillary for stroboscopic imaging is presented. A sample characterized by a known periodic event is studied with a synchronized vibrating capillary.

  5. Vibration-type particle separation device with piezoceramic vibrator

    NASA Astrophysics Data System (ADS)

    Ooe, Katsutoshi; Doi, Akihiro

    2008-12-01

    During hemanalysis, it is necessary to separate blood cells from whole blood. Many blood separation methods, for example, centrifugation and filtering, are in practical use. However, the use of these methods involves problems from the perspectives of processing speed and processing volume. We develop new types of blood separation devices that use piezo-ceramic vibrators. The first device uses a capillary. One end of the capillary is fixed to the device frame, and the other is fixed to a piezo-ceramic vibrator. The vibrator transmits bending waves to the capillary. This device can process only a small amount of solution; therefore, it is not suitable for hemanalysis. In order to solve this problem, we developed a second device; this device has a pair of thin glass plates with a small gap as a substitute for the capillary used in the first device. These devices are based on the fact that particles heavier than water move toward transverse velocity antinodes while those lighter than water move toward velocity nodes. In this report, we demonstrate the highspeed separation of silica microbeads and 50-vol% glycerol water by using these devices. The first device can separate the abovementioned solution within 3 min while the second can separate it within 1 min. Both devices are driven by a rectangular wave of 15 to 20 Vpp. Furthermore, it has been confirmed that red blood cells are separated from diluted whole blood using the first device within approximately 1 min. These devices have transparency, so they can compose as the analysis system with the chemical analyzer easily.

  6. Hand tremor and activity sensor

    NASA Technical Reports Server (NTRS)

    Konigsberg, E.

    1975-01-01

    System detects hand tremor and activity and transmitting signals over distance of at least 3 meters to receiver system. Designed for use in studies of effect of fatigue on individual's judgement or reaction time, sensor is installed within mounting of finger-ring; no external wiring or power source is needed.

  7. A pilot study of gene expression analysis in workers with hand-arm vibration syndrome.

    PubMed

    Maeda, Setsuo; Yu, Xiaozhong; Wang, Rui-Sheng; Sakakibara, Hisataka

    2008-04-01

    The purpose of this pilot study was to examine differences in gene expressions by cDNA microarray analysis of hand-arm vibration syndrome (HAVS) patients. Vein blood samples were collected and total RNA was extracted. All blood samples were obtained in the morning in one visit after a standard light breakfast. We performed microarray analysis with the labeled cDNA prepared by reverse transcription from RNA samples, using the Human CHIP version 1 (DNA Chip Research Inc, Yokohama, Japan). There are 2,976 genes on the chip, and these genes were selected from a cDNA library prepared with human peripheral white blood cells (WBC). Different gene levels between the HAVS patients and controls, and between groups of HAVS with different levels of symptoms, were indicated by the randomized variance model. The most up-regulated genes were analyzed for their possible functions and association with the occurrence of HAVS. From the results of this pilot study, although the results were obtained a limited number of subjects, it would appear that cDNA microarray analysis of HAVS patients has potential as a new objective method of HAVS diagnosis. Further research is needed to examine the gene expression with increased numbers of patients at different stages of HAVS.

  8. Uptake and quality of health surveillance for noise and hand-arm vibration.

    PubMed

    Poole, K; Mason, H J; Harris-Roberts, J

    2011-08-01

    Health surveillance (HS) is required for employees if noise or hand-arm vibration (HAV) exposures are likely to be above exposure action levels. The extent to which employers comply with Health and Safety Executive (HSE) regulations is unclear. To establish the uptake and quality of HS for noise and HAV in high-risk industries. A cross-sectional telephone-based questionnaire study involving employers in high-risk industries for noise or HAV. A total of 246 and 386 interviews were completed for noise and HAV, respectively. The uptake of HS in the cohorts was 17 and 10%, respectively. Selection of those companies thought to have 'higher risk' increased the uptake to 25 and 18%, respectively. The proportion of companies carrying out HS was strongly related to the size of the company, with smaller companies less likely to provide this for their employees. A large proportion of companies that reported having HS in place had formal procedures for managing exposed workers (90 and 83% for noise and HAV, respectively), received feedback on individual workers (81 and 80%) and some reported that they used this information to inform their risk management process (58 and 63%). The frequency of HS for HAV was in line with that suggested in HSE guidance in 70% of cases, however, for noise, it was often utilized more frequently. While many of the companies appear to be following HSE guidance, there is a significant number that are not. Further initiatives that engage with smaller companies may help increase HS provision.

  9. Vibration studies of a lightweight three-sided membrane suitable for space application

    NASA Technical Reports Server (NTRS)

    Sewell, J. L.; Miserentino, R.; Pappa, R. S.

    1983-01-01

    Vibration studies carried out in a vacuum chamber are reported for a three-sided membrane with inwardly curved edges. Uniform tension was transmitted by thin steel cables encased in the edges. Variation of ambient air pressure from atmospheric to near vacuum resulted in increased response frequencies and amplitudes. The first few vibration modes measured in a near vacuum are shown to be predictable by a finite element structural analysis over a range of applied tension loads. The complicated vibration mode behavior observed during tests at various air pressures is studied analytically with a nonstructural effective air-mass approximation. The membrane structure is a candidate for reflective surfaces in space antennas.

  10. Effect of acupuncture at right Hoku point on the bilateral vibration-induced finger flexion reflex in man.

    PubMed

    Takakura, N; Kanamaru, A; Sibuya, M; Homma, I

    1992-01-01

    Vibration applied to the volar side of the finger tip has been reported to induce finger flexion reflex. Acupuncture is reported to inhibit this vibration-induced finger flexion reflex (VFR) in the ipsilateral hand. The purpose of this study was to investigate the effect of unilateral acupuncture in the hand on VFR in both hands. As no systematic study on the relationship between VFR and the force of voluntary contraction with no vibration (Initial Force: IF) has been reported, this relationship was studied prior to the present study on acupuncture. VFR was induced by mechanical vibration on the volar side of the middle finger tip with 10 g to 500 g IF. With approximately 300 g IF, VFR was consistent. Therefore, approximately 300 g IF was applied for VFR induction to study the effect of acupuncture on VFR. A stainless steel needle was inserted into the right Hoku point and remained inserted (in-situ technique) for 10 minutes. VFR in both hands was significantly decreased by acupuncture at the right Hoku point (% control force of VFR: right, 67.8%; left, 74.6%). The present results suggest that acupuncture in the unilateral hand influences the bilateral reflex arc of VFR.

  11. Hand-arm vibration in the aetiology of hearing loss in lumberjacks.

    PubMed Central

    Pyykkö, I; Starck, J; Färkkilä, M; Hoikkala, M; Korhonen, O; Nurminen, M

    1981-01-01

    A longitudinal study of hearing loss was conducted among a group of lumberjacks in the years 1972 and 1974--8. The number of subjects increased from 72 in 1972 to 203 in 1978. They were classified according to (1) a history of vibration-induced white finger (VWF), (2) age, (3) duration of exposure, an (4) duration of ear muff usage. The hearing level at 4000 Hz was used to indicate the noise-induced permanent threshold shift (NIPTS). The lumberjacks were exposed, at their present pace of work, to noise, Leq values 96-103 dB(A), and to the vibration of a chain saw (linear acceleration 30-70 ms-2). The chain saws of the early 1960s were more hazardous, with the average noise level of 111 dB(A) and a variation acceleration of 60-180 ms-2. When classified on the basis of age, the lumberjacks with VWF had about a 10 dB greater NIPTS than subjects without VWF. NIPTS increased with the duration of exposure to chain saw noise, but with equal noise exposure the NIPTS was about 10 dB greater in lumberjacks with VWF than without VWF. With the same duration of ear protection the lumberjacks with VWF consistently had about a 10 dB greater NIPTS than those without VWF. The differences in NIPTS were statistically significant. The possible reason for more advanced NIPTS in subjects with VWF is that vibration might operate in both of these disorders through a common mechanism--that is, producing a vasoconstriction in both cochlear and digital blood vessels as a result of sympathetic nervous system activity. PMID:7272242

  12. Vibration analysis of the SA349/2 helicopter

    NASA Technical Reports Server (NTRS)

    Heffernan, Ruth; Precetti, Dominique; Johnson, Wayne

    1991-01-01

    Helicopter airframe vibration is examined using calculations and measurements for the SA349/2 research helicopter. The hub loads, which transmit excitations to the fuselage, are predicted using a comprehensive rotorcraft analysis and correlated with measuring hub loads. The predicted and measured hub loads are then coupled with finite element models representing the SA349/2 fuselage. The resulting vertical acceleration at the pilot seat is examined. Adjustments are made to the airframe structural models to examine the sensitivity of predicted vertical acceleration to the model. Changes of a few percent to the damping and frequency of specific models lead to large reductions in predicted vibration, and to major improvements in the correlations with measured pilot-seat vertical acceleration.

  13. A 6-DOF vibration isolation system for hydraulic hybrid vehicles

    NASA Astrophysics Data System (ADS)

    Nguyen, The; Elahinia, Mohammad; Olson, Walter W.; Fontaine, Paul

    2006-03-01

    This paper presents the results of vibration isolation analysis for the pump/motor component of hydraulic hybrid vehicles (HHVs). The HHVs are designed to combine gasoline/diesel engine and hydraulic power in order to improve the fuel efficiency and reduce the pollution. Electric hybrid technology is being applied to passenger cars with small and medium engines to improve the fuel economy. However, for heavy duty vehicles such as large SUVs, trucks, and buses, which require more power, the hydraulic hybridization is a more efficient choice. In function, the hydraulic hybrid subsystem improves the fuel efficiency of the vehicle by recovering some of the energy that is otherwise wasted in friction brakes. Since the operation of the main component of HHVs involves with rotating parts and moving fluid, noise and vibration are an issue that affects both passengers (ride comfort) as well as surrounding people (drive-by noise). This study looks into the possibility of reducing the transmitted noise and vibration from the hydraulic subsystem to the vehicle's chassis by using magnetorheological (MR) fluid mounts. To this end, the hydraulic subsystem is modeled as a six degree of freedom (6-DOF) rigid body. A 6-DOF isolation system, consisting of five mounts connected to the pump/motor at five different locations, is modeled and simulated. The mounts are designed by combining regular elastomer components with MR fluids. In the simulation, the real loading and working conditions of the hydraulic subsystem are considered and the effects of both shock and vibration are analyzed. The transmissibility of the isolation system is monitored in a wide range of frequencies. The geometry of the isolation system is considered in order to sustain the weight of the hydraulic system without affecting the design of the chassis and the effectiveness of the vibration isolating ability. The simulation results shows reduction in the transmitted vibration force for different working cycles of

  14. A comparison of hand-arm vibration syndrome between Malaysian and Japanese workers.

    PubMed

    Su, Anselm Ting; Fukumoto, Jin; Darus, Azlan; Hoe, Victor C W; Miyai, Nobuyuki; Isahak, Marzuki; Takemura, Shigeki; Bulgiba, Awang; Yoshimasu, Kouichi; Maeda, Setsuo; Miyashita, Kazuhisa

    2013-01-01

    The aim of this study was to investigate the clinical characteristics of HAVS in a tropical environment in comparison with a temperate environment. We conducted a series medical examinations among the forestry, construction and automobile industry workers in Malaysia adopting the compulsory medical examination procedure used by Wakayama Medical University for Japanese vibratory tools workers. We matched the duration of vibration exposure and compared our results against the Japanese workers. We also compared the results of the Malaysian tree fellers against a group of symptomatic Japanese tree fellers diagnosed with HAVS. Malaysian subjects reported a similar prevalence of finger tingling, numbness and dullness (Malaysian=25.0%, Japanese=21.5%, p=0.444) but had a lower finger skin temperature (FST) and higher vibrotactile perception threshold (VPT) values as compared with the Japanese workers. No white finger was reported in Malaysian subjects. The FST and VPT of the Malaysian tree fellers were at least as bad as the Japanese tree fellers despite a shorter duration (mean difference=20.12 years, 95%CI=14.50, 25.40) of vibration exposure. Although the vascular disorder does not manifest clinically in the tropical environment, the severity of HAVS can be as bad as in the temperate environment with predominantly neurological disorder. Hence, it is essential to formulate national legislation for the control of the occupational vibration exposure.

  15. Parameter optimization of an inerter-based isolator for passive vibration control of Michelangelo's Rondanini Pietà

    NASA Astrophysics Data System (ADS)

    Siami, A.; Karimi, H. R.; Cigada, A.; Zappa, E.; Sabbioni, E.

    2018-01-01

    Preserving cultural heritage against earthquake and ambient vibrations can be an attractive topic in the field of vibration control. This paper proposes a passive vibration isolator methodology based on inerters for improving the performance of the isolation system of the famous statue of Michelangelo Buonarroti Pietà Rondanini. More specifically, a five-degree-of-freedom (5DOF) model of the statue and the anti-seismic and anti-vibration base is presented and experimentally validated. The parameters of this model are tuned according to the experimental tests performed on the assembly of the isolator and the structure. Then, the developed model is used to investigate the impact of actuation devices such as tuned mass-damper (TMD) and tuned mass-damper-inerter (TMDI) in vibration reduction of the structure. The effect of implementation of TMDI on the 5DOF model is shown based on physical limitations of the system parameters. Simulation results are provided to illustrate effectiveness of the passive element of TMDI in reduction of the vibration transmitted to the statue in vertical direction. Moreover, the optimal design parameters of the passive system such as frequency and damping coefficient will be calculated using two different performance indexes. The obtained optimal parameters have been evaluated by using two different optimization algorithms: the sequential quadratic programming method and the Firefly algorithm. The results prove significant reduction in the transmitted vibration to the structure in the presence of the proposed tuned TMDI, without imposing a large amount of mass or modification to the structure of the isolator.

  16. Influence of support conditions on vertical whole-body vibration of the seated human body.

    PubMed

    M-Pranesh, Anand; Rakheja, Subhash; Demont, Richard

    2010-01-01

    The vibration transmission to the lumbar and thoracic segments of seated human subjects exposed to whole body vibration of a vehicular nature have been mostly characterised without the back and hand supports, which is not representative of general driving conditions. This non-invasive experimental study investigated the transmission of vertical seat vibration to selected vertebrae and the head along the vertical and fore-aft axes of twelve male human subjects seated on a rigid seat and exposed to random vertical excitation in the 0.5-20 Hz range. The measurements were performed under four different sitting postures involving combinations of back support conditions and hands positions, and three difference magnitudes of vertical vibration (0.25, 0.5 and 1.0 m/s(2) rms acceleration). The results showed significant errors induced by sensor misalignment and skin effects, which required appropriate correction methodologies. The averaged corrected responses revealed that the back support attenuates vibration in the vertical axis to all the body locations while increasing the fore-aft transmissibility at the C7 and T5. The hands position generally has a relatively smaller effect, showing some influences on the C7 and L5 vibration. Sitting without a back support resulted in very low magnitude fore-aft vibration at T5, which was substantially higher with a back support, suggestive of a probable change in the body's vibration mode. The effect of back support was observed to be very small on the horizontal vibration of the lower thoracic and lumbar regions. The results suggest that distinctly different target body-segment biodynamic functions need to be defined for different support conditions in order to represent the unique contribution of the specific support condition. These datasets may then be useful for the development of biodynamic models.

  17. The relationship between clinical and standardized tests for hand-arm vibration syndrome.

    PubMed

    Poole, C J M; Mason, H; Harding, A-H

    2016-06-01

    Standardized laboratory tests are undertaken to assist the diagnosis and staging of hand-arm vibration syndrome (HAVS), but the strength of the relationship between the tests and clinical stages of HAVS is unknown. To assess the relationship between the results of thermal aesthesiometry (TA), vibrotactile (VT) thresholds and cold provocation (CP) tests with the modified Stockholm scales for HAVS and to determine whether the relationship is affected by finger skin temperature. Consecutive records of workers referred to a Tier 5 HAVS assessment centre from 2006 to 2015 were identified. The diagnosis and staging of cases was undertaken from the clinical information contained in the records. Cases with alternative or mixed diagnoses were excluded and staging performed according to the modified Stockholm scale without knowledge of the results of the standardized laboratory tests. A total of 279 cases of HAVS were analysed. Although there was a significant trend for sensorineural (SN) and vascular scores to increase with clinical stage (P < 0.01), there was no significant difference in scores between 2SN early and 2SN late or between 2SN late and 3SN. There was moderate correlation between the TA and VT scores and the clinical SN stages (r = 0.6). This correlation did not change when subjects were divided into those with a finger skin temperature <30 and >30°C. CP scores distributed bimodally and correlated poorly with clinical staging (r = 0.2). Standardized SN tests distinguish between the lower Stockholm stages, but not above 2SN early. This has implications for health surveillance and UK policy. © Crown copyright 2016.

  18. Vibration condition measure instrument of motor using MEMS accelerometer

    NASA Astrophysics Data System (ADS)

    Chen, Jun

    2018-04-01

    In this work, a novel vibration condition measure instrument of motor using a digital micro accelerometer is proposed. In order to reduce the random noise found in the data, the sensor modeling is established and also the Kalman filter (KMF) is developed. According to these data from KMF, the maximum vibration displacement is calculated by the integration algorithm with the DC bias removed. The high performance micro controller unit (MCU) is used in the implementation of controller. By the IIC digital interface port, the data are transmitted from sensor to controller. The hardware circuits of the sensor and micro controller are designed and tested. With the computational formula of maximum displacement and FFT, the high precession results of displacement and frequency are gotten. Finally, the paper presents various experimental results to prove that this instrument is suitable for application in electrical motor vibration measurement.

  19. Emitted vibration measurement device and method

    NASA Astrophysics Data System (ADS)

    Gisler, G. L.

    1986-10-01

    This invention is directed to a method and apparatus for measuring emitted vibrational forces produced by a reaction wheel assembly due to imbalances, misalignment, bearing defects and the like. The apparatus includes a low mass carriage supported on a large mass base. The carriage is in the form of an octagonal frame having an opening which is adapted for receiving the reaction wheel assembly supported thereon by means of a mounting ring. The carriage is supported on the base by means of air bearings which support the carriage in a generally frictionless manner when supplied with compressed air from a source. A plurality of carriage brackets and a plurality of base blocks provided for physical coupling of the base and carriage. The sensing axes of the load cells are arranged generally parallel to the base and connected between the base and carriage such that all of the vibrational forces emitted by the reaction wheel assembly are effectively transmitted through the sensing axes of the load cells. In this manner, a highly reliable and accurate measurment of the vibrational forces of the reaction wheel assembly can be had. The output signals from the load cells are subjected to a dynamical analyzer which analyzes and identifies the rotor and spin bearing components which are causing the vibrational forces.

  20. Validation of Force Limited Vibration Testing at NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Rice, Chad; Buehrle, Ralph D.

    2003-01-01

    Vibration tests were performed to develop and validate the forced limited vibration testing capability at the NASA Langley Research Center. The force limited vibration test technique has been utilized at the Jet Propulsion Laboratory and other NASA centers to provide more realistic vibration test environments for aerospace flight hardware. In standard random vibration tests, the payload is mounted to a rigid fixture and the interface acceleration is controlled to a specified level based on a conservative estimate of the expected flight environment. In force limited vibration tests, both the acceleration and force are controlled at the mounting interface to compensate for differences between the flexible flight mounting and rigid test fixture. This minimizes the over test at the payload natural frequencies and results in more realistic forces being transmitted at the mounting interface. Force and acceleration response data was provided by NASA Goddard Space Flight Center for a test article that was flown in 1998 on a Black Brant sounding rocket. The measured flight interface acceleration data was used as the reference acceleration spectrum. Using this acceleration spectrum, three analytical methods were used to estimate the force limits. Standard random and force limited vibration tests were performed and the results are compared with the flight data.

  1. Summary of semi-initiative and initiative control automobile engine vibration

    NASA Astrophysics Data System (ADS)

    Qu, Wei; Qu, Zhou

    2009-07-01

    Engine vibration accounts for around 55% of automobile vibration, separating the engine vibration from transmitting to automobile to the utmost extent is significant for improving NVH performance. Semi-initiative and initiative control of engine vibration is one of the hot spots of technical research in domestic and foreign automobile industry, especially luxury automobiles which adopt this technology to improve amenity and competitiveness. This article refers to a large amount of domestic and foreign related materials, fully introduces the research status of semi-initiative and initiative control suspension of engine vibration suspension and many kinds of structural style, and provides control policy and method of semi-initiative and initiative control suspension system. Compare and analyze the structural style of semi-initiative and initiative control and merits and demerits of current structures of semi-initiative and initiative control of mechanic electrorheological, magnetorheological, electromagnetic actuator, piezoelectric ceramics, electrostriction material, pneumatic actuator etc. Models of power assembly mounting system was classified.Calculation example indicated that reasonable selection of engine mounting system parameters is useful to reduce engine vibration transmission and to increase ride comfort. Finally we brought forward semi-initiative and initiative suspension which might be applied for automobiles, and which has a promising future.

  2. Static hand gesture recognition from a video

    NASA Astrophysics Data System (ADS)

    Rokade, Rajeshree S.; Doye, Dharmpal

    2011-10-01

    A sign language (also signed language) is a language which, instead of acoustically conveyed sound patterns, uses visually transmitted sign patterns to convey meaning- "simultaneously combining hand shapes, orientation and movement of the hands". Sign languages commonly develop in deaf communities, which can include interpreters, friends and families of deaf people as well as people who are deaf or hard of hearing themselves. In this paper, we proposed a novel system for recognition of static hand gestures from a video, based on Kohonen neural network. We proposed algorithm to separate out key frames, which include correct gestures from a video sequence. We segment, hand images from complex and non uniform background. Features are extracted by applying Kohonen on key frames and recognition is done.

  3. Circuit For Control Of Electromechanical Prosthetic Hand

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr.

    1995-01-01

    Proposed circuit for control of electromechanical prosthetic hand derives electrical control signals from shoulder movements. Updated, electronic version of prosthesis, that includes two hooklike fingers actuated via cables from shoulder harness. Circuit built around favored shoulder harness, provides more dexterous movement, without incurring complexity of computer-controlled "bionic" or hydraulically actuated devices. Additional harness and potentiometer connected to similar control circuit mounted on other shoulder. Used to control stepping motor rotating hand about prosthetic wrist to one of number of angles consistent with number of digital outputs. Finger-control signals developed by circuit connected to first shoulder harness transmitted to prosthetic hand via sliprings at prosthetic wrist joint.

  4. Apparatus and method for suppressing vibration and displacement of a bellows

    DOEpatents

    Kuklo, T.C.

    1984-01-01

    Flexible bellows are utilized between two systems, such as a pumping system and a process station, to partially absorb system vibrations and to compensate for misalignment between the systems. It is common practice to either clamp a rigid spacer between flanges of the two systems to separate them from each other, or to maintain the bellows in unsupported relationship between these systems. In the former bellows arrangement, the rigid spacer transmits vibratory energy between the two systems and the bellows tends to function as an undamped or underdamped unit that resonates at its own frequency to create additional vibratory energy, transmitted to the systems. In the latter, unsupported bellows arrangement, the pressure differential prevalent between the fluid flowing through the bellows and ambient normally causes extension or retraction of the bellows and resulting misalignment problems. The present invention substantially solves the above vibration and misalignment problems by providing an inflatable tube in surrounding relationship about a bellows to suppress vibration and displacement thereof. A method for isolating first and second systems from each other to prevent the transmission of vibratory energy therebetween comprises the steps of attaching at least one flexible bellows between the systems, surrounding the bellows with an inflatable tube, and maintaining a predetermined pressure in the tube to urge the tube in flexible contact with at least some of the convolutions of the bellows.

  5. Relationship between hand-arm vibration exposure and onset time for symptoms in a heavy engineering production workshop.

    PubMed

    Burström, Lage; Hagberg, Mats; Lundström, Ronnie; Nilsson, Tohr

    2006-06-01

    This study examined onset time for reported vascular and neurological symptoms in relation to the vibration load in a group of workers exposed to vibration. Information on the self-stated year for the first occurrence of symptoms was collected by means of questionnaires. During interviews data were obtained on self-stated estimations of daily exposure time, type of tool, and number of months or years with different exposures. The estimations of the vibration magnitudes of exposure were based on conducted measurements. From these data, the individual vibration exposure at the time of onset of symptoms was calculated. The incidence was 25.6 and 32.9 per 1000 exposure years for vascular and neurological symptoms, respectively, in the group of workers. The first onset of symptoms appeared after an average of 12 years of exposure. For the workers, the symptoms of vascular or neurological disorders started after about the same number of exposure years. The calculated accumulated acceleration correlated best with the onset time of symptoms. It was concluded that, since the workers' exposure to vibration was below the action level established in the European vibration directive, the results suggest that the action level is not a safe level for avoiding vascular and neurological symptoms.

  6. Digital vibration threshold testing and ergonomic stressors in automobile manufacturing workers: a cross-sectional assessment.

    PubMed

    Gold, J E; Punnett, L; Cherniack, M; Wegman, D H

    2005-01-01

    Upper extremity musculoskeletal disorders (UEMSDs) comprise a large proportion of work-related illnesses in the USA. Physical risk factors including manual force and segmental vibration have been associated with UEMSDs. Reduced sensitivity to vibration in the fingertips (a function of nerve integrity) has been found in those exposed to segmental vibration, to hand force, and in office workers. The objective of this study was to determine whether an association exists between digital vibration thresholds (VTs) and exposure to ergonomic stressors in automobile manufacturing. Interviews and physical examinations were conducted in a cross-sectional survey of workers (n = 1174). In multivariable robust regression modelling, associations with workers' estimates of ergonomic stressors stratified on tool use were determined. VTs were separately associated with hand force, vibration as felt through the floor (whole body vibration), and with an index of multiple exposures in both tool users and non-tool users. Additional associations with contact stress and awkward upper extremity postures were found in tool users. Segmental vibration was not associated with VTs. Further epidemiologic and laboratory studies are needed to confirm the associations found. The association with self-reported whole body vibration exposure suggests a possible sympathetic nervous system effect, which remains to be explored.

  7. Responses of Diaphorina citri (Hemiptera: Psyllidae) to conspecific vibrational signals and synthetic mimics

    USDA-ARS?s Scientific Manuscript database

    Mate-seeking in Diaphorina citri Kuwayama, a vector of the economically damaging huanglongbing citrus disease, typically includes male-female duetting behaviors. First, the male calls by beating its wings at ca. 170-250 Hz, producing vibrations that are transmitted along the host tree branches to th...

  8. Vibration welding system with thin film sensor

    DOEpatents

    Cai, Wayne W; Abell, Jeffrey A; Li, Xiaochun; Choi, Hongseok; Zhao, Jingzhou

    2014-03-18

    A vibration welding system includes an anvil, a welding horn, a thin film sensor, and a process controller. The anvil and horn include working surfaces that contact a work piece during the welding process. The sensor measures a control value at the working surface. The measured control value is transmitted to the controller, which controls the system in part using the measured control value. The thin film sensor may include a plurality of thermopiles and thermocouples which collectively measure temperature and heat flux at the working surface. A method includes providing a welder device with a slot adjacent to a working surface of the welder device, inserting the thin film sensor into the slot, and using the sensor to measure a control value at the working surface. A process controller then controls the vibration welding system in part using the measured control value.

  9. Noninterference Systems Developed for Measuring and Monitoring Rotor Blade Vibrations

    NASA Technical Reports Server (NTRS)

    Kurkov, Anatole P.

    2003-01-01

    In the noninterference measurement of blade vibrations, a laser light beam is transmitted to the rotor blade tips through a single optical fiber, and the reflected light from the blade tips is collected by a receiving fiber-optic bundle and conducted to a photodetector. Transmitting and receiving fibers are integrated in an optical probe that is enclosed in a metal tube which also houses a miniature lens that focuses light on the blade tips. Vibratory blade amplitudes can be deduced from the measurement of the instantaneous time of arrival of the blades and the knowledge of the rotor speed. The in-house noninterference blade-vibration measurement system was developed in response to requirements to monitor blade vibrations in several tests where conventional strain gauges could not be installed or where there was a need to back up strain gauges should critical gauges fail during the test. These types of measurements are also performed in the aircraft engine industry using proprietary in-house technology. Two methods of measurement were developed for vibrations that are synchronous with a rotor shaft. One method requires only one sensor; however, it is necessary to continuously record the data while the rotor is being swept through the resonance. In the other method, typically four sensors are employed and the vibratory amplitude is deduced from the data by performing a least square fit to a harmonic function. This method does not require continuous recording of data through the resonance and, therefore, is better suited for monitoring. The single-probe method was tested in the Carl facility at the Wright- Patterson Air Force Base, and the multiple-probe method was tested in NASA Glenn Research Center's Spin Rig facility, which uses permanent magnets to excite synchronous vibrations. Representative results from this test are illustrated in the bar chart. Nonsynchronous vibrations were measured online during testing of the Quiet High Speed Fan in Glenn s 9- by 15-Foot

  10. Effects of wrist tendon vibration on arm tracking in people poststroke.

    PubMed

    Conrad, Megan O; Scheidt, Robert A; Schmit, Brian D

    2011-09-01

    The goal of this study was to evaluate the influence of wrist tendon vibration on a multijoint elbow/shoulder tracking task. We hypothesized that tendon vibration applied at the wrist musculature would improve upper arm tracking performance in chronic stroke survivors through increased, Ia-afferent feedback to the central nervous system (CNS). To test this hypothesis, 10 chronic stroke and 5 neurologically intact subjects grasped the handle of a planar robot as they tracked a target through a horizontal figure-8 pattern. A total of 36 trials were completed by each subject. During the middle trials, 70-Hz tendon vibration was applied at the wrist flexor tendons. Position, velocity, and electromyography data were evaluated to compare the quality of arm movements before, during, and after trials with concurrent vibration. Despite tracking a target that moved at a constant velocity, hand trajectories appeared to be segmented, displaying alternating intervals of acceleration and deceleration. Segments were identifiable in tangential velocity data as single-peaked, bell-shaped speed pulses. When tendon vibration was applied at the wrist musculature, stroke subjects experienced improved tracking performance in that hand path lengths and peak speed variability decreased, whereas movement smoothness increased. These performance improvements were accompanied by decreases in the muscle activity during movement. Possible mechanisms behind improved movement control in response to tendon vibration may include improved sensorimotor integration or improved cortical modulation of spinal reflex activity.

  11. Effects of wrist tendon vibration on arm tracking in people poststroke

    PubMed Central

    Conrad, Megan O.; Scheidt, Robert A.

    2011-01-01

    The goal of this study was to evaluate the influence of wrist tendon vibration on a multijoint elbow/shoulder tracking task. We hypothesized that tendon vibration applied at the wrist musculature would improve upper arm tracking performance in chronic stroke survivors through increased, Ia-afferent feedback to the central nervous system (CNS). To test this hypothesis, 10 chronic stroke and 5 neurologically intact subjects grasped the handle of a planar robot as they tracked a target through a horizontal figure-8 pattern. A total of 36 trials were completed by each subject. During the middle trials, 70-Hz tendon vibration was applied at the wrist flexor tendons. Position, velocity, and electromyography data were evaluated to compare the quality of arm movements before, during, and after trials with concurrent vibration. Despite tracking a target that moved at a constant velocity, hand trajectories appeared to be segmented, displaying alternating intervals of acceleration and deceleration. Segments were identifiable in tangential velocity data as single-peaked, bell-shaped speed pulses. When tendon vibration was applied at the wrist musculature, stroke subjects experienced improved tracking performance in that hand path lengths and peak speed variability decreased, whereas movement smoothness increased. These performance improvements were accompanied by decreases in the muscle activity during movement. Possible mechanisms behind improved movement control in response to tendon vibration may include improved sensorimotor integration or improved cortical modulation of spinal reflex activity. PMID:21697444

  12. Decreasing sound and vibration during ground transport of infants with very low birth weight.

    PubMed

    Prehn, J; McEwen, I; Jeffries, L; Jones, M; Daniels, T; Goshorn, E; Marx, C

    2015-02-01

    To measure the effectiveness of modifications to reduce sound and vibration during interhospital ground transport of a simulated infant with very low birth weight (VLBW) and a gestational age of 30 weeks, a period of high susceptibility to germinal matrix and intraventricular hemorrhage. Researchers measured vibration and sound levels during infant transport, and compared levels after modifications to the transport incubator mattresses, addition of vibration isolators under incubator wheels, addition of mass to the incubator mattress and addition of incubator acoustic cover. Modifications did not decrease sound levels inside the transport incubator during transport. The combination of a gel mattress over an air chambered mattress was effective in decreasing vibration levels for the 1368 g simulated infant. Transport mattress effectiveness in decreasing vibration is influenced by infant weight. Modifications that decrease vibration for infants weighing 2000 g are not effective for infants with VLBW. Sound levels are not affected by incubator covers, suggesting that sound is transmitted into the incubator as a low-frequency vibration through the incubator's contact with the ambulance. Medical transportation can apply industrial methods of vibration and sound control to protect infants with VLBW from excessive physical strain of transport during vulnerable periods of development.

  13. Train-induced field vibration measurements of ground and over-track buildings.

    PubMed

    Zou, Chao; Wang, Yimin; Moore, James A; Sanayei, Masoud

    2017-01-01

    Transit-oriented development, such as metro depot and over-track building complexes, has expanded rapidly over the last 5years in China. Over-track building construction has the advantage of comprehensive utilization of land resources, ease of commuting to work, and provide funds for subway construction. But the high frequency of subway operations into and out of the depots can generate excessive vibrations that transmit into the over track buildings, radiate noise within the buildings, hamper the operation of vibration sensitive equipment, and adversely affect the living quality of the building occupants. Field measurements of vibration during subway operations were conducted at Shenzhen, China, a city of 10.62 million people in southern China. Considering the metro depot train testing line and throat area train lines were the main vibration sources, vibration data were captured in five measurement setups. The train-induced vibrations were obtained and compared with limitation of FTA criteria. The structure-radiated noise was calculated using measured vibration levels. The vertical vibration energy directly passed through the columns on both sides of track into the platform, amplifying vibration on the platform by up to 6dB greater than ground levels at testing line area. Vibration amplification around the natural frequency in the vertical direction of over-track building made the peak values of indoor floor vibration about 16dB greater than outdoor platform vibration. We recommend to carefully examining design of new over-track buildings within 40m on the platform over the throat area to avoid excessive vertical vibrations and noise. For both buildings, the measured vertical vibrations were less than the FTA limit. However, it is demonstrated that the traffic-induced high-frequency noise has the potential to annoy occupants on the upper floors. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Distributing Data from Desktop to Hand-Held Computers

    NASA Technical Reports Server (NTRS)

    Elmore, Jason L.

    2005-01-01

    A system of server and client software formats and redistributes data from commercially available desktop to commercially available hand-held computers via both wired and wireless networks. This software is an inexpensive means of enabling engineers and technicians to gain access to current sensor data while working in locations in which such data would otherwise be inaccessible. The sensor data are first gathered by a data-acquisition server computer, then transmitted via a wired network to a data-distribution computer that executes the server portion of the present software. Data in all sensor channels -- both raw sensor outputs in millivolt units and results of conversion to engineering units -- are made available for distribution. Selected subsets of the data are transmitted to each hand-held computer via the wired and then a wireless network. The selection of the subsets and the choice of the sequences and formats for displaying the data is made by means of a user interface generated by the client portion of the software. The data displayed on the screens of hand-held units can be updated at rates from 1 to

  15. Comparative studies of perceived vibration strength for commercial mobile phones.

    PubMed

    Lee, Heow Pueh; Lim, Siak Piang

    2014-05-01

    A mobile phone, also known as cell phone or hand phone, is among the most popular electrical devices used by people all over the world. The present study examines the vibration perception of mobile phones by co-relating the relevant design parameters such as excitation frequency, and size and mass of mobile phones to the vibration perception survey by volunteers. Five popular commercially available mobile phone models were tested. The main findings for the perception surveys were that higher vibration frequency and amplitude of the peak acceleration would result in stronger vibration perception of the mobile phones. A larger contact surface area with the palms and figures, higher peak acceleration and the associated larger peak inertia force may be the main factors for the relatively higher vibration perception. The future design for the vibration alert of the mobile phones is likely to follow this trend. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  16. [Effect of vibration caused by time-varying magnetic fields on diffusion-weighted MRI].

    PubMed

    Ogura, Akio; Maeda, Fumie; Miyai, Akira; Hayashi, Kohji; Hongoh, Takaharu

    2006-04-20

    Diffusion-weighted images (DWIs) with high b-factor in the body are often used to detect and diagnose cancer at MRI. The echo planar imaging (EPI) sequence and high motion probing gradient pulse are used at diffusion weighted imaging, causing high table vibration. The purpose of this study was to assess whether the diffusion signal and apparent diffusion coefficient (ADC) values are influenced by this vibration because of time-varying magnetic fields. Two DWIs were compared. In one, phantoms were fixed on the MRI unit's table transmitting the vibration. In the other, phantoms were supported in air, in the absence of vibration. The phantoms called "solution phantoms" were made from agarose of a particular density. The phantoms called "jelly phantoms" were made from agarose that was heated. The diffusion signal and ADC value of each image were compared. The results showed that the signal of DWI units using the solution phantom was not affected by vibration. However, the signal of DWI and ADC were increased in the low-density jelly phantom as a result of vibration, causing the jelly phantom to vibrate. The DWIs of vibrating regions such as the breast maybe be subject to error. A countermeasure seems to be to support the region adequately.

  17. A comparison of different vibration exercise techniques on neuromuscular performance.

    PubMed

    García-Gutiérrez, M T; Rhea, M R; Marín, P J

    2014-09-01

    The first purpose of this study was to determine the effects of whole-body vibration (WBV) exercise during an isometric hand-grip exercise. The second purpose was to evaluate whether more than one vibratory focus would evoke an increase in the effects evoked by only one vibratory focus. The present study investigated whether WBV exposure during 10 repetitions of a handgrip dynamometer while standing on a WBV platform. Twenty-eight recreationally active university students completed 3 different test conditions, in random order: 1) grip dynamometer exercise with superimposed WBV and contralateral arm vibration (WBV+AV); 2) superimposed arm vibration only (AV); 3) grip dynamometer exercise without vibration (Control). The hand grip strength was slightly higher in the WBV condition as compared to the Control and AV conditions (1.1% and 3.6%, p>0.05, respectively). A main effect of the EMGrms of extensor digitorum muscle (ED) was observed indicating that the WBV+AV condition produced a lower co-activation of ED during a flexor digital task than the Control and AV (p<0.05) conditions. The application of WBV+AV may acutely increase muscle coordination and decreases the coactivation of ED. Furthermore, the muscle EMGrms showed increases in activation near the vibratory focus in both upper- and lower-body.

  18. Impaired Vibration of Auditory Ossicles in Osteopetrotic Mice

    PubMed Central

    Kanzaki, Sho; Takada, Yasunari; Niida, Shumpei; Takeda, Yoshihiro; Udagawa, Nobuyuki; Ogawa, Kaoru; Nango, Nobuhito; Momose, Atsushi; Matsuo, Koichi

    2011-01-01

    In the middle ear, a chain of three tiny bones (ie, malleus, incus, and stapes) vibrates to transmit sound from the tympanic membrane to the inner ear. Little is known about whether and how bone-resorbing osteoclasts play a role in the vibration of auditory ossicles. We analyzed hearing function and morphological features of auditory ossicles in osteopetrotic mice, which lack osteoclasts because of the deficiency of either cytokine RANKL or transcription factor c-Fos. The auditory brainstem response showed that mice of both genotypes experienced hearing loss, and laser Doppler vibrometry revealed that the malleus behind the tympanic membrane failed to vibrate. Histological analysis and X-ray tomographic microscopy using synchrotron radiation showed that auditory ossicles in osteopetrotic mice were thicker and more cartilaginous than those in control mice. Most interestingly, the malleal processus brevis touched the medial wall of the tympanic cavity in osteopetrotic mice, which was also the case for c-Src kinase–deficient mice (with normal numbers of nonresorbing osteoclasts). Osteopetrotic mice showed a smaller volume of the tympanic cavity but had larger auditory ossicles compared with controls. These data suggest that osteoclastic bone resorption is required for thinning of auditory ossicles and enlargement of the tympanic cavity so that auditory ossicles vibrate freely. PMID:21356377

  19. Avoiding the Health Hazard of People from Construction Vehicles: A Strategy for Controlling the Vibration of a Wheel Loader.

    PubMed

    Chi, Feng; Zhou, Jun; Zhang, Qi; Wang, Yong; Huang, Panling

    2017-03-08

    The vibration control of a construction vehicle must be carried out in order to meet the aims of sustainable environmental development and to avoid the potential human health hazards. In this paper, based on market feedback, the driver seat vibration of a type of wheel loader in the left and right direction, is found to be significant over a certain speed range. In order to find abnormal vibration components, the order tracking technique (OTT) and transmission path analysis (TPA) were used to analyze the vibration sources of the wheel loader. Through this analysis, it can be seen that the abnormal vibration comes from the interaction between the tire tread and the road, and this is because the vibration was amplified by the cab mount, which was eventually transmitted to the cab seat. Finally, the seat vibration amplitudes were decreased by up to 50.8%, after implementing the vibration reduction strategy.

  20. Evaluation of reaction time performance and subjective drowsiness during whole-body vibration exposure

    NASA Astrophysics Data System (ADS)

    Azizan, A.; Zali, Z.; Padil, H.

    2018-05-01

    Despite the automotive industry’s interest in how vibration affects the level of human comfort, there is little focus on the effect of vibration on drowsiness level. Thus, this study involves eighteen healthy male participants to study the effect of exposure to vibration on the drowsiness level. Prior to the experiment, the total transmitted vibration measured at interfaces between the seat pan and seat back to the human body for each participant was modified to become 0.2 ms-2 r.m.s and 0.4 ms-2 r.m.s. During the experiment, the participants were seated and exposed to 20-minutes of Gaussian random vibration with frequency band 1-15 Hz at two level of amplitude (low vibration amplitude and medium vibration amplitude) on separate days. The level of drowsiness was measured using a PVT test prior and after exposure to the vibration while participants rated their subjective drowsiness by using the Karolinska Sleepiness Scale (KSS). The significant increase in the number of lapse and reaction time because of the exposure to vibration in both conditions provide strong evidence of drowsiness. In this regard, the medium vibration amplitude shows a more prominent effect. All participants have shown a steady increase of drowsiness level in KSS. Meanwhile, there are no significant differences found between low vibration amplitude and medium vibration amplitude in the KSS. These findings suggest that human alertness level is greatly affected by the exposure to vibration and these effects are more pronounced at higher vibration amplitude. Both findings indicate that the presence of vibration promotes drowsiness, especially at higher vibration amplitude.

  1. Dissipative gravitational bouncer on a vibrating surface

    NASA Astrophysics Data System (ADS)

    Espinoza Ortiz, J. S.; Lagos, R. E.

    2017-12-01

    We study the dynamical behavior of a particle flying under the influence of a gravitational field, with dissipation constant λ (Stokes-like), colliding successive times against a rigid surface vibrating harmonically with restitution coefficient α. We define re-scaled dimensionless dynamical variables, such as the relative particle velocity Ω with respect to the surface’s velocity; and the real parameter τ accounting for the temporal evolution of the system. At the particle-surface contact point and for the k‧th collision, we construct the mapping described by (τk ; Ω k ) in order to analyze the system’s nonlinear dynamical behavior. From the dynamical mapping, the fixed point trajectory is computed and its stability is analyzed. We find the dynamical behavior of the fixed point trajectory to be stable or unstable, depending on the values of the re-scaled vibrating surface amplitude Γ, the restitution coefficient α and the damping constant λ. Other important dynamical aspects such as the phase space volume and the one cycle vibrating surface (decomposed into absorbing and transmitting regions) are also discussed. Furthermore, the model rescues well known results in the limit λ = 0.

  2. Apparatus and method for suppressing vibration and displacement of a bellows

    DOEpatents

    Kuklo, Thomas C.

    1985-01-01

    Flexible bellows are utilized between two systems, such as a pumping system and a process station, to partially absorb system vibrations and to compensate for misalignment between the systems. It is common practice to either clamp a rigid spacer between flanges of the two systems (FIG. 3B) to separate them from each other, or to maintain the bellows in unsupported relationship between these systems (FIG. 4B). In the former bellows arrangement, the rigid spacer transmits vibratory energy between the two systems and the bellows tends to function as an undamped or underdamped unit that resonates at its own frequency to create additional vibratory energy, transmitted to the systems. In the latter, unsupported bellows arrangement (FIG. 4B), the pressure differential prevalent between the fluid flowing through the bellows and ambient normally causes extension or retraction of the bellows and resulting misalignment problems. The present invention substantially solves the above vibration and misalignment problems by providing an inflatable tube (20) in surrounding relationship about a bellows (14) to suppress vibration and displacement thereof. A method for isolating first and second systems (11,12) from each other to prevent the transmission of vibratory energy therebetween comprises the steps of attaching at least one flexible bellows (14) between the systems (11,12), surrounding the bellows with an inflatable tube (20), and maintaining a predetermined pressure in the tube (20) to urge the tube in flexible contact with at least some of the convolutions of the bellows (14).

  3. Noise-induced hearing loss and combined noise and vibration exposure.

    PubMed

    Turcot, A; Girard, S A; Courteau, M; Baril, J; Larocque, R

    2015-04-01

    While there is a wide body of literature addressing noise-induced hearing loss (NIHL) and hand-arm vibration syndrome (HAVS) independently, relatively few studies have considered the combined effects of noise and vibration. These studies have suggested an increased risk of NIHL in workers with vibration white finger (VWF), though the relationship remains poorly understood. To determine whether hearing impairment is worse in noise-exposed workers with VWF than in workers with similar noise exposures but without VWF. The Quebec National Institute of Public Health audiometric database was used in conjunction with work-related accident and occupational diseases data from the Quebec workers' compensation board to analyse differences in audiometry results between vibration-exposed workers in the mining and forestry industries and the overall source population, and between mining and forestry workers with documented VWF and those without VWF. The International Organization for Standardization (ISO) 7029 standards were used to calculate hearing loss not attributable to age. 15751 vibration-exposed workers were identified in an overall source population of 59339. Workers with VWF (n = 96) had significantly worse hearing at every frequency studied (500, 1000, 2000 4000 Hz) compared with other mining and forestry workers without VWF. This study confirms previous findings of greater hearing loss at higher frequencies in workers with VWF, but also found a significant difference in hearing loss at low frequencies. It therefore supports the association between combined noise and hand-arm vibration (HAV) exposure and NIHL. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. The diagnostic value of finger systolic blood pressure and cold-provocation testing for the vascular component of hand-arm vibration syndrome in health surveillance.

    PubMed

    Poole, K; Elms, J; Mason, H J

    2004-12-01

    Hand-arm vibration syndrome (HAVS) is a complex condition with vascular, sensorineural and musculoskeletal components. A number of quantitative tests have been used for assisting in the diagnosis of HAVS and grading disease severity. To investigate and compare the diagnostic value of finger systolic blood pressure (FSBP) and rewarming of finger skin temperature (FST) following cold-provocation testing, in the assessment of vascular HAVS. Twenty-four individuals with vascular HAVS (Stockholm Workshop stage 2 or 3V) and 22 control subjects underwent FSBP measurements at 30, 15 and 10 degrees C and monitoring of FST following immersion of the hands in water at 15 degrees C for 5 min. There was a significant reduction in median FSBP% in the vascular HAVS group in the change in FSBP from 30 to 15 degrees C adjusted for brachial blood pressure (FSBPC%). There was no difference in the median time for FST to rewarm by 4 degrees C between HAVS cases and controls. The sensitivity and specificity of FSBP to discriminate between the groups varied between 44 and 61% and 91 and 95%, respectively. The sensitivity and specificity for the time for FST to rewarm by 4 degrees C were 71 and 77%. There is little evidence that the described form of finger rewarming after cold-provocation testing is a useful diagnostic test for vascular HAVS, although it may have some moderate influence in ruling out vascular problems. Based on our data, the FSBP may also have limited use in confirming a positive diagnosis of vibration-induced vascular problems. The higher specificity of the FSBP test suggests it may have some value in ruling out the vascular component of HAVS. The data from this study do not confirm the diagnostic power of FSBP for the vascular component of HAVS reported by a few other investigators.

  5. Effect of bit wear on hammer drill handle vibration and productivity.

    PubMed

    Antonucci, Andrea; Barr, Alan; Martin, Bernard; Rempel, David

    2017-08-01

    The use of large electric hammer drills exposes construction workers to high levels of hand vibration that may lead to hand-arm vibration syndrome and other musculoskeletal disorders. The aim of this laboratory study was to investigate the effect of bit wear on drill handle vibration and drilling productivity (e.g., drilling time per hole). A laboratory test bench system was used with an 8.3 kg electric hammer drill and 1.9 cm concrete bit (a typical drill and bit used in commercial construction). The system automatically advanced the active drill into aged concrete block under feed force control to a depth of 7.6 cm while handle vibration was measured according to ISO standards (ISO 5349 and 28927). Bits were worn to 4 levels by consecutive hole drilling to 4 cumulative drilling depths: 0, 1,900, 5,700, and 7,600 cm. Z-axis handle vibration increased significantly (p<0.05) from 4.8 to 5.1 m/s 2 (ISO weighted) and from 42.7-47.6 m/s 2 (unweighted) when comparing a new bit to a bit worn to 1,900 cm of cumulative drilling depth. Handle vibration did not increase further with bits worn more than 1900 cm of cumulative drilling depth. Neither x- nor y-axis handle vibration was effected by bit wear. The time to drill a hole increased by 58% for the bit with 5,700 cm of cumulative drilling depth compared to a new bit. Bit wear led to a small but significant increase in both ISO weighted and unweighted z-axis handle vibration. Perhaps more important, bit wear had a large effect on productivity. The effect on productivity will influence a worker's allowable daily drilling time if exposure to drill handle vibration is near the ACGIH Threshold Limit Value. [1] Construction contractors should implement a bit replacement program based on these findings.

  6. Avoiding the Health Hazard of People from Construction Vehicles: A Strategy for Controlling the Vibration of a Wheel Loader

    PubMed Central

    Chi, Feng; Zhou, Jun; Zhang, Qi; Wang, Yong; Huang, Panling

    2017-01-01

    The vibration control of a construction vehicle must be carried out in order to meet the aims of sustainable environmental development and to avoid the potential human health hazards. In this paper, based on market feedback, the driver seat vibration of a type of wheel loader in the left and right direction, is found to be significant over a certain speed range. In order to find abnormal vibration components, the order tracking technique (OTT) and transmission path analysis (TPA) were used to analyze the vibration sources of the wheel loader. Through this analysis, it can be seen that the abnormal vibration comes from the interaction between the tire tread and the road, and this is because the vibration was amplified by the cab mount, which was eventually transmitted to the cab seat. Finally, the seat vibration amplitudes were decreased by up to 50.8%, after implementing the vibration reduction strategy. PMID:28282849

  7. An Active Micro Vibration Isolator with Zero-Power Controlled Magnetic Suspension Technology

    NASA Astrophysics Data System (ADS)

    Hoque, Md. Emdadul; Takasaki, Masaya; Ishino, Yuji; Suzuki, Hirohisa; Mizuno, Takeshi

    In this paper, a three-degree-of-freedom vibration isolation system using active zero-power controlled magnetic suspension is presented in order to isolate vibrations transmitted from the ground and to attenuate the effect of direct disturbances on the table. The zero-compliance of the isolator for direct disturbances was realized by connecting a conventional mechanical spring in series with a negative spring produced by an active magnetic suspension mechanism. In this work, each degree-of-freedom-of-motion of the vibration isolator is treated analytically and it is shown that the developed system is capable to generate infinite stiffness in each mode. Experimental studies have been conducted as well to measure the effectiveness of the isolator under both types of disturbances. Further improvements for the developed system as well as the control techniques are also discussed.

  8. Polyvinylidene fluoride (PVDF) vibration sensor for stethoscope and contact microphones

    NASA Astrophysics Data System (ADS)

    Toda, Minoru; Thompson, Mitchell

    2005-09-01

    This paper describes a new type of contact vibration sensor made by bonding piezoelectric PVDF film to a curved frame structure. The concave surface of the film is bonded to a rubber piece having a front contact face. Vibration is transmitted from this face through the rubber to the surface of the PVDF film. Pressure normal to the surface of the film is converted to circumferential strain, and an electric field is induced by the piezoelectric effect. The frequency response of the device was measured using an accelerometer mounted between the rubber face and a rigid vibration exciter plate. Sensitivity (voltage per unit displacement) was deduced from the device output and measured acceleration. The sensitivity was flat from 16 Hz to 3 kHz, peaking at 6 kHz due to a structural resonance. Calculations predicting performance against human tissue (stethoscope or contact microphone) show results similar to data measured against the metal vibrator. This implies that an accelerometer can be used for calibrating a stethoscope or contact microphone. The observed arterial pulse waveform showed more low-frequency content than a conventional electronic stethoscope.

  9. Site-Specific Transmission of a Floor-Based, High-Frequency, Low-Magnitude Vibration Stimulus in Children With Spastic Cerebral Palsy.

    PubMed

    Singh, Harshvardhan; Whitney, Daniel G; Knight, Christopher A; Miller, Freeman; Manal, Kurt; Kolm, Paul; Modlesky, Christopher M

    2016-02-01

    To determine the degree to which a high-frequency, low-magnitude vibration signal emitted by a floor-based platform transmits to the distal tibia and distal femur of children with spastic cerebral palsy (CP) during standing. Cross-sectional study. University research laboratory. Children with spastic CP who could stand independently (n=18) and typically developing children (n=10) (age range, 4-12y) participated in the study (N=28). Not applicable. The vibration signal at the high-frequency, low-magnitude vibration platform (approximately 33Hz and 0.3g), distal tibia, and distal femur was measured using accelerometers. The degree of plantar flexor spasticity was assessed using the Modified Ashworth Scale. The high-frequency, low-magnitude vibration signal was greater (P<.001) at the distal tibia than at the platform in children with CP (.36±.06g vs .29±.05g) and controls (.40±.09g vs .24±.07g). Although the vibration signal was also higher at the distal femur (.35±.09g, P<.001) than at the platform in controls, it was lower in children with CP (.20±.07g, P<.001). The degree of spasticity was negatively related to the vibration signal transmitted to the distal tibia (Spearman ρ=-.547) and distal femur (Spearman ρ=-.566) in children with CP (both P<.05). A high-frequency, low-magnitude vibration signal from a floor-based platform was amplified at the distal tibia, attenuated at the distal femur, and inversely related to the degree of muscle spasticity in children with spastic CP. Whether this transmission pattern affects the adaptation of the bones of children with CP to high-frequency, low-magnitude vibration requires further investigation. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  10. Active vibration control on a quarter-car for cancellation of road noise disturbance

    NASA Astrophysics Data System (ADS)

    Belgacem, Walid; Berry, Alain; Masson, Patrice

    2012-07-01

    In this paper, a methodology is presented for the cancellation of road noise, from the analysis of vibration transmission paths for an automotive suspension to the design of an active control system using inertial actuators on a suspension to reduce the vibrations transmitted to the chassis. First, experiments were conducted on a Chevrolet Epica LS automobile on a concrete test track to measure accelerations induced on the suspension by the road. These measurements were combined with experimental Frequency Response Functions (FRFs) measured on a quarter-car test bench to reconstruct an equivalent three dimensional force applied on the wheel hub. Second, FRFs measured on the test bench between the three-dimensional driving force and forces at each suspension/chassis linkage were used to characterize the different transmission paths of vibration energy to the chassis. Third, an experimental model of the suspension was constructed to simulate the configuration of the active control system, using the primary (disturbance) FRFs and secondary (control) FRFs also measured on the test bench. This model was used to optimize the configuration of the control actuators and to evaluate the required forces. Finally, a prototype of an active suspension was implemented and measurements were performed in order to assess the performance of the control approach. A 4.6 dB attenuation on transmitted forces was obtained in the 50-250 Hz range.

  11. Effects of different vibration exercises on bench press.

    PubMed

    Marín, P J; Torres-Luque, G; Hernández-García, R; García-López, D; Garatachea, N

    2011-10-01

    This study was undertaken to analyze the effects of different vibration recovery strategies via feet or hands on the number of repetitions performed and on mean velocity, peak velocity and blood lactate concentration during consecutive bench-press sets. 9 elite judo athletes performed 3 sets of bench press at 60% of one-repetition maximum (1RM), leading to failure and allowing a 180 s rest period between sets. During the rest period, 1 of the 3 following procedures was performed: 150 s rest plus 30 s push-up vibration exercise (Push-up), 150 s rest plus 30 s squat vibration exercise (Squat) or 180 s only rest (Passive). Statistical analysis revealed that the Squat condition resulted in a significant increase in the number of repetitions achieved, in comparison with all other rest strategies. However, kinematic parameters and blood lactate concentration were not affected by vibration. These data suggest that a vibration stimulus applied to the feet, between sets, can result in positive improvements in upper body resistance exercise performance. Although the mechanisms are not fully understood, this positive effect of vibration could be due to an increased motor cortex excitability and voluntary drive. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Modeling of biodynamic responses distributed at the fingers and the palm of the human hand-arm system.

    PubMed

    Dong, Ren G; Dong, Jennie H; Wu, John Z; Rakheja, Subhash

    2007-01-01

    The objective of this study is to develop analytical models for simulating driving-point biodynamic responses distributed at the fingers and palm of the hand under vibration along the forearm direction (z(h)-axis). Two different clamp-like model structures are formulated to analyze the distributed responses at the fingers-handle and palm-handle interfaces, as opposed to the single driving point invariably considered in the reported models. The parameters of the proposed four- and five degrees-of-freedom models are identified through minimization of an rms error function of the model and measured responses under different hand actions, namely, fingers pull, push only, grip only, and combined push and grip. The results show that the responses predicted from both models agree reasonably well with the measured data in terms of distributed as well total impedance magnitude and phase. The variations in the identified model parameters under different hand actions are further discussed in view of the biological system behavior. The proposed models are considered to serve as useful tools for design and assessment of vibration isolation methods, and for developing a hand-arm simulator for vibration analysis of power tools.

  13. Cold-provocation testing for the vascular component of hand-arm vibration syndrome in health surveillance.

    PubMed

    Poole, Kerry; Elms, Joanne; Mason, Howard

    2006-10-01

    The aim was to investigate whether the use of infra-red thermography (I-R) and measurement of temperature gradients along the finger could improve the diagnostic accuracy of cold-provocation testing (15 degrees C for 5 min) in vascular hand-arm vibration syndrome (HAVS). Twenty-one controls and 33 individuals with stages 2/3V HAVS were studied. The standard measurement of time to rewarm by 4 degrees C (T4 degrees C) and temperature gradients between the finger tip, base and middle (measured using I-R) were calculated. Receiver Operating Characteristics (ROC) analysis to distinguish between the two groups revealed that for T4 degrees C the area under the ROC curve was not statistically significantly different from 0.5 (0.64 95% confidence interval 0.49-0.76). The difference between the tip and middle portion of the finger during the sixth minute of recovery was the most promising gradient with an area of 0.76 (95% confidence interval 0.62-0.87), and sensitivity and specificity of 57.6% and 85.7% respectively. However, this was not significantly different from that for the time to rewarm by 4 degrees C. In conclusion, the cold-provocation test used in this study does not appear to discriminate between individuals with stage 2/3V HAVS and controls and this is not improved by the measurement of temperature gradients along the fingers using I-R.

  14. The epidemiology of soil-transmitted helminths in Bihar State, India.

    PubMed

    Greenland, Katie; Dixon, Ruth; Khan, Shabbir Ali; Gunawardena, Kithsiri; Kihara, Jimmy H; Smith, Jennifer L; Drake, Lesley; Makkar, Prerna; Raman, Sri; Singh, Sarman; Kumar, Sanjay

    2015-05-01

    Soil-transmitted helminths (STHs) infect over a billion individuals worldwide. In India, 241 million children are estimated to need deworming to avert the negative consequences STH infections can have on child health and development. In February-April 2011, 17 million children in Bihar State were dewormed during a government-led school-based deworming campaign. Prior to programme implementation, a study was conducted to assess STH prevalence in the school-age population to direct the programme. The study also investigated risk factors for STH infections, including caste, literacy, and defecation and hygiene practices, in order to inform the development of complementary interventions. A cross-sectional survey was conducted among children in 20 schools in Bihar. In addition to providing stool samples for identification of STH infections, children completed a short questionnaire detailing their usual defecation and hand-hygiene practices. Risk factors for STH infections were explored. In January-February 2011, 1279 school children aged four to seventeen provided stool samples and 1157 children also completed the questionnaire. Overall, 68% of children (10-86% across schools) were infected with one or more soil-transmitted helminth species. The prevalence of ascariasis, hookworm and trichuriasis was 52%, 42% and 5% respectively. The majority of children (95%) practiced open defecation and reported most frequently cleansing hands with soil (61%). Increasing age, lack of maternal literacy and certain castes were independently associated with hookworm infection. Absence of a hand-washing station at the schools was also independently associated with A. lumbricoides infection. STH prevalence in Bihar is high, and justifies mass deworming in school-aged children. Open defecation is common-place and hands are often cleansed using soil. The findings reported here can be used to help direct messaging appropriate to mothers with low levels of literacy and emphasise the

  15. Triboelectric Nanogenerator as a Self-Powered Communication Unit for Processing and Transmitting Information.

    PubMed

    Yu, Aifang; Chen, Xiangyu; Wang, Rui; Liu, Jingyu; Luo, Jianjun; Chen, Libo; Zhang, Yang; Wu, Wei; Liu, Caihong; Yuan, Hongtao; Peng, Mingzeng; Hu, Weiguo; Zhai, Junyi; Wang, Zhong Lin

    2016-04-26

    In this paper, we demonstrate an application of a triboelectric nanogenerator (TENG) as a self-powered communication unit. An elaborately designed TENG is used to translate a series of environmental triggering signals into binary digital signals and drives an electronic-optical device to transmit binary digital data in real-time without an external power supply. The elaborately designed TENG is built in a membrane structure that can effectively drive the electronic-optical device in a bandwidth from 1.30 to 1.65 kHz. Two typical communication modes (amplitude-shift keying and frequency-shift keying) are realized through the resonant response of TENG to different frequencies, and two digital signals, i.e., "1001" and "0110", are successfully transmitted and received through this system, respectively. Hence, in this study, a simple but efficient method for directly transmitting ambient vibration to the receiver as a digital signal is established using an elaborately designed TENG and an optical communication technique. This type of the communication system, as well as the implementation method presented, exhibits great potential for applications in the smart city, smart home, password authentication, and so on.

  16. Vibration syndrome in chipping and grinding workers.

    PubMed

    1984-10-01

    time and automation of the finishing process. Tool manufacturers can contribute by modifying or redesigning tools to reduce vibration. The technology to reduce vibration from hand tools exists but the engineering application is difficult. Vibration from chain saws has been reduced through changes in design and some companies have begun to redesign jackhammers, scalers, grinders, and chipping hammers. As these become available, purchasers can encourage manufacturers by selecting tools with antivibration characteristics. Vibration from tools currently in use can be controlled by periodically scheduled inspection and maintenance programs for vibrating tools.(ABSTRACT TRUNCATED AT 400 WORDS)

  17. The Effects of Industrial Protective Gloves and Hand Skin Temperatures on Hand Grip Strength and Discomfort Rating

    PubMed Central

    2017-01-01

    Daily working activities and functions require a high contribution of hand and forearm muscles in executing grip force. To study the effects of wearing different gloves on grip strength, under a variety of hand skin temperatures, an assessment of the maximum grip strength was performed with 32 healthy male workers with a mean age (standard deviation) of 30.44 (5.35) years wearing five industrial gloves at three hand skin temperatures. Their ages and anthropometric characteristics including body mass index (BMI), hand length, hand width, hand depth, hand palm, and wrist circumference were measured. The hand was exposed to different bath temperatures (5 °C, 25 °C, and 45 °C) and hand grip strength was measured using a Jamar hydraulic hand dynamometer with and without wearing the gloves (chemical protection glove, rubber insulating glove, anti-vibration impact glove, cotton yarn knitted glove, and RY-WG002 working glove). The data were analyzed using the Shapiro–Wilk test, Pearson correlation coefficient, Tukey test, and analysis of variance (ANOVA) of the within-subject design analysis. The results showed that wearing gloves significantly affected the maximum grip strength. Wearing the RY-WG002 working glove produced a greater reduction on the maximum grip when compared with the bare hand, while low temperatures (5 °C) had a significant influence on grip when compared to medium (25 °C) and high (45 °C) hand skin temperatures. In addition, participants felt more discomfort in both environmental extreme conditions. Furthermore, they reported more discomfort while wearing neoprene, rubber, and RY-WG002 working gloves. PMID:29207573

  18. Vibration and shape control of hinged light structures using electromagnetic forces

    NASA Astrophysics Data System (ADS)

    Matsuzaki, Yuji; Miyachi, Shigenobu; Sasaki, Toshiyuki

    2003-08-01

    This paper describes a new electromagnetic device for vibration control of a light-weighted deployable/retractable structure which consists of many small units connected with mechanical hinges. A typical example of such a structure is a solar cell paddle of an artificial satellite which is composed of many thin flexible blankets connected in series. Vibration and shape control of the paddle is not easy, because control force and energy do not transmit well between the blankets which are discretely connected by hinges with each other. The new device consists of a permanent magnet glued along an edge of a blanket and an electric current-conducting coil glued along an adjoining edge of another adjacent blanket. Conduction of the electric current in a magnetic field from the magnet generates an electromagnetic force on the coil. By changing the current in the coil, therefore, we may control the vibration and shape of the blankets. To confirm the effectiveness of the new device, constructing a simple paddle model consisting eight hinge- panels, we have carried out a model experiment of vibration and shape control of the paddle. In addition, a numerical simulation of vibration control of the hinge structure is performed to compare with measured data.

  19. Effects of vibration on occupant driving performance under simulated driving conditions.

    PubMed

    Azizan, Amzar; Fard, M; Azari, Michael F; Jazar, Reza

    2017-04-01

    Although much research has been devoted to the characterization of the effects of whole-body vibration on seated occupants' comfort, drowsiness induced by vibration has received less attention to date. There are also little validated measurement methods available to quantify whole body vibration-induced drowsiness. Here, the effects of vibration on drowsiness were investigated. Twenty male volunteers were recruited for this experiment. Drowsiness was measured in a driving simulator, before and after 30-min exposure to vibration. Gaussian random vibration, with 1-15 Hz frequency bandwidth was used for excitation. During the driving session, volunteers were required to obey the speed limit of 100 kph and maintain a steady position on the left-hand lane. A deviation in lane position, steering angle variability, and speed deviation were recorded and analysed. Alternatively, volunteers rated their subjective drowsiness by Karolinska Sleepiness Scale (KSS) scores every 5-min. Following 30-min of exposure to vibration, a significant increase of lane deviation, steering angle variability, and KSS scores were observed in all volunteers suggesting the adverse effects of vibration on human alertness level. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Vibration isolation of automotive vehicle engine using periodic mounting systems

    NASA Astrophysics Data System (ADS)

    Asiri, S.

    2005-05-01

    Customer awareness and sensitivity to noise and vibration levels have been raised through increasing television advertisement, in which the vehicle noise and vibration performance is used as the main market differentiation. This awareness has caused the transportation industry to regard noise and vibration as important criteria for improving market shares. One industry that tends to be in the forefront of the technology to reduce the levels of noise and vibration is the automobile industry. Hence, it is of practical interest to reduce the vibrations induced structural responses. The automotive vehicle engine is the main source of mechanical vibrations of automobiles. The engine is vulnerable to the dynamic action caused by engine disturbance force in various speed ranges. The vibrations of the automotive vehicle engines may cause structural failure, malfunction of other parts, or discomfort to passengers because of high level noise and vibrations. The mounts of the engines act as the transmission paths of the vibrations transmitted from the excitation sources to the body of the vehicle and passengers. Therefore, proper design and control of these mounts are essential to the attenuation of the vibration of platform structures. To improve vibration resistant capacities of engine mounting systems, vibration control techniques may be used. For instance, some passive and semi-active dissipation devices may be installed at mounts to enhance vibration energy absorbing capacity. In the proposed study, a radically different concept is presented whereby periodic mounts are considered because these mounts exhibit unique dynamic characteristics that make them act as mechanical filters for wave propagation. As a result, waves can propagate along the periodic mounts only within specific frequency bands called the "Pass Bands" and wave propagation is completely blocked within other frequency bands called the "Stop Bands". The experimental arrangements, including the design of

  1. Vibration characteristics of dental high-speed turbines and speed-increasing handpieces.

    PubMed

    Poole, Ruth L; Lea, Simon C; Dyson, John E; Shortall, Adrian C C; Walmsley, A Damien

    2008-07-01

    Vibrations of dental handpieces may contribute to symptoms of hand-arm vibration syndrome in dental personnel and iatrogenic enamel cracking in teeth. However, methods for measuring dental handpiece vibrations have previously been limited and information about vibration characteristics is sparse. This preliminary study aimed to use a novel approach to assess the vibrations of unloaded high-speed handpieces in vitro. Maximum vibration displacement amplitudes of five air turbines and two speed-increasing handpieces were recorded whilst they were operated with and without a rotary cutting instrument (RCI) using a scanning laser vibrometer (SLV). RCI rotation speeds, calculated from frequency peaks, were consistent with expected values. ANOVA statistical analysis indicated significant differences in vibrations between handpiece models (p<0.01), although post hoc tests revealed that differences between most individual models were not significant (p>0.11). Operating handpieces with a RCI resulted in greater vibrations than with no RCI (p<0.01). Points on the head of the handpiece showed greater vibration displacement amplitudes than points along the body (p<0.01). Although no single measurement exceeded 4 microm for the handpieces in the current test setup (implying that these vibrations may be unlikely to cause adverse effects), this study has formed the basis for future work which will include handpiece vibration measurements whilst cutting under clinically representative loads.

  2. Effective information campaign for management of exposure to hand-arm vibration in the metal and construction industries.

    PubMed

    Sauni, Riitta; Toivio, Pauliina; Esko, Toppila; Pääkkönen, Rauno; Uitti, Jukka

    2015-01-01

    European Directive 2002/44/EC defines employers' responsibilities in the risk management of hand-arm vibration (HAV). However, the directive is still not completely implemented in all risk industries. The aim of our study was to determine whether it is possible to improve the recognition and management of the risks of HAV at workplaces with a one-year information campaign. A questionnaire on opinions and measures for controlling HAV exposure at workplaces was sent to all occupational safety representatives and occupational safety managers in the construction and metal industry in Finland (n=1887) and once again to those who responded to the first questionnaire (n=961) one year after the campaign. The campaign increased recognition of HAV in risk assessment from 57.0% to 68.3% (p=.001), increased measures to decrease exposure to HAV from 54.6% to 64.2% (p=.006) and increased the number of programmes to control the risks due to HAV (p<.001). The information campaign, which focuses on the construction and metal industries, proved to be effective in increasing the awareness of the risks of HAV and the measures needed to control exposure to HAV. A similar campaign can be recommended in the case of risks specific to certain occupations.

  3. No Telescoping Effect with Dual Tendon Vibration.

    PubMed

    Bellan, Valeria; Wallwork, Sarah B; Stanton, Tasha R; Reverberi, Carlo; Gallace, Alberto; Moseley, G Lorimer

    2016-01-01

    The tendon vibration illusion has been extensively used to manipulate the perceived position of one's own body part. However, findings from previous research do not seem conclusive sregarding the perceptual effect of the concurrent stimulation of both agonist and antagonist tendons over one joint. On the basis of recent data, it has been suggested that this paired stimulation generates an inconsistent signal about the limb position, which leads to a perceived shrinkage of the limb. However, this interesting effect has never been replicated. The aim of the present study was to clarify the effect of a simultaneous and equal vibration of the biceps and triceps tendons on the perceived location of the hand. Experiment 1 replicated and extended the previous findings. We compared a dual tendon stimulation condition with single tendon stimulation conditions and with a control condition (no vibration) on both 'upward-downward' and 'towards-away from the elbow' planes. Our results show a mislocalisation towards the elbow of the position of the vibrated arm during dual vibration, in line with previous results; however, this did not clarify whether the effect was due to arm representation contraction (i.e., a 'telescoping' effect). Therefore, in Experiment 2 we investigated explicitly and implicitly the perceived arm length during the same conditions. Our results clearly suggest that in all the vibration conditions there was a mislocalisation of the entire arm (including the elbow), but no evidence of a contraction of the perceived arm length.

  4. Energy evaluation of protection effectiveness of anti-vibration gloves.

    PubMed

    Hermann, Tomasz; Dobry, Marian Witalis

    2017-09-01

    This article describes an energy method of assessing protection effectiveness of anti-vibration gloves on the human dynamic structure. The study uses dynamic models of the human and the glove specified in Standard No. ISO 10068:2012. The physical models of human-tool systems were developed by combining human physical models with a power tool model. The combined human-tool models were then transformed into mathematical models from which energy models were finally derived. Comparative energy analysis was conducted in the domain of rms powers. The energy models of the human-tool systems were solved using numerical simulation implemented in the MATLAB/Simulink environment. The simulation procedure demonstrated the effectiveness of the anti-vibration glove as a method of protecting human operators of hand-held power tools against vibration. The desirable effect is achieved by lowering the flow of energy in the human-tool system when the anti-vibration glove is employed.

  5. Modeling of the interaction between grip force and vibration transmissibility of a finger.

    PubMed

    Wu, John Z; Welcome, Daniel E; McDowell, Thomas W; Xu, Xueyan S; Dong, Ren G

    2017-07-01

    It is known that the vibration characteristics of the fingers and hand and the level of grip action interacts when operating a power tool. In the current study, we developed a hybrid finger model to simulate the vibrations of the hand-finger system when gripping a vibrating handle covered with soft materials. The hybrid finger model combines the characteristics of conventional finite element (FE) models, multi-body musculoskeletal models, and lumped mass models. The distal, middle, and proximal finger segments were constructed using FE models, the finger segments were connected via three flexible joint linkages (i.e., distal interphalangeal joint (DIP), proximal interphalangeal joint (PIP), and metacarpophalangeal (MCP) joint), and the MCP joint was connected to the ground and handle via lumped parameter elements. The effects of the active muscle forces were accounted for via the joint moments. The bone, nail, and hard connective tissues were assumed to be linearly elastic whereas the soft tissues, which include the skin and subcutaneous tissues, were considered as hyperelastic and viscoelastic. The general trends of the model predictions agree well with the previous experimental measurements in that the resonant frequency increased from proximal to the middle and to the distal finger segments for the same grip force, that the resonant frequency tends to increase with increasing grip force for the same finger segment, especially for the distal segment, and that the magnitude of vibration transmissibility tends to increase with increasing grip force, especially for the proximal segment. The advantage of the proposed model over the traditional vibration models is that it can predict the local vibration behavior of the finger to a tissue level, while taking into account the effects of the active musculoskeletal force, the effects of the contact conditions on vibrations, the global vibration characteristics. Published by Elsevier Ltd.

  6. Effects of acute upper-body vibration on strength and power variables in climbers.

    PubMed

    Cochrane, Darryl J; Hawke, Emma J

    2007-05-01

    Whole-body vibration training has recently received a lot of attention with reported enhancements of strength and power qualities in athletes. This study investigated whether upper-body vibration would be able to augment muscular attributes for climbing performance. Twelve healthy active climbers volunteered for the study. All participants underwent 3 treatments--arm cranking (AC), upper-body vibration (UBV), and non-UBV (NUBV)--in a balanced random order, conducted on separate days. Upper-body vibration was generated via a commercialized electric-powered dumbbell with a rotating axis that delivered oscillatory movements to the shoulders and arms. The UBV treatment consisted of performing 5 upper-body exercises for a total duration of 5 minutes. The UBV frequency was set at 26 Hz, amplitude 3 mm. For the NUBV treatment, the participants performed the exact exercises and time constraints as UBV; however, the vibration dumbbell was set at 0 Hz and 0 mm amplitude. The third treatment consisted of AC, which was performed at 75 k.min(-1) for 5 minutes. Pre- and postmuscular performance measures of medicine ball throw, hand grip strength, and a specific climbing maneuver were performed after each treatment. There were no significant treatment differences on medicine ball throw, hand grip strength, and the specific climbing maneuver. Acute UBV exposure did not demonstrate the expected potential neuromuscular enhancements on the climbing performance tests selected for this study.

  7. Force reflecting hand controller for manipulator teleoperation

    NASA Technical Reports Server (NTRS)

    Bryfogle, Mark D.

    1991-01-01

    A force reflecting hand controller based upon a six degree of freedom fully parallel mechanism, often termed a Stewart Platform, has been designed, constructed, and tested as an integrated system with a slave robot manipulator test bed. A force reflecting hand controller comprises a kinesthetic device capable of transmitting position and orientation commands to a slave robot manipulator while simultaneously representing the environmental interaction forces of the slave manipulator back to the operator through actuators driving the hand controller mechanism. The Stewart Platform was chosen as a novel approach to improve force reflecting teleoperation because of its inherently high ratio of load generation capability to system mass content and the correspondingly high dynamic bandwidth. An additional novelty of the program was to implement closed loop force and torque control about the hand controller mechanism by equipping the handgrip with a six degree of freedom force and torque measuring cell. The mechanical, electrical, computer, and control systems are discussed and system tests are presented.

  8. Bubble Size Distribution in a Vibrating Bubble Column

    NASA Astrophysics Data System (ADS)

    Mohagheghian, Shahrouz; Wilson, Trevor; Valenzuela, Bret; Hinds, Tyler; Moseni, Kevin; Elbing, Brian

    2016-11-01

    While vibrating bubble columns have increased the mass transfer between phases, a universal scaling law remains elusive. Attempts to predict mass transfer rates in large industrial scale applications by extrapolating laboratory scale models have failed. In a stationary bubble column, mass transfer is a function of phase interfacial area (PIA), while PIA is determined based on the bubble size distribution (BSD). On the other hand, BSD is influenced by the injection characteristics and liquid phase dynamics and properties. Vibration modifies the BSD by impacting the gas and gas-liquid dynamics. This work uses a vibrating cylindrical bubble column to investigate the effect of gas injection and vibration characteristics on the BSD. The bubble column has a 10 cm diameter and was filled with water to a depth of 90 cm above the tip of the orifice tube injector. BSD was measured using high-speed imaging to determine the projected area of individual bubbles, which the nominal bubble diameter was then calculated assuming spherical bubbles. The BSD dependence on the distance from the injector, injector design (1.6 and 0.8 mm ID), air flow rates (0.5 to 5 lit/min), and vibration conditions (stationary and vibration conditions varying amplitude and frequency) will be presented. In addition to mean data, higher order statistics will also be provided.

  9. [Magnetic resonance imaging for the wrist joint of the coal miners in vibration department].

    PubMed

    Zhao, Xuan-zhi; Liu, Rui-lian; Hu, Shu-dong; Zhang, Wei; Xu, Wen-xiu; Ge, Ling-xia

    2006-04-01

    To study the magnetic resonance imaging (MRI) in the wrist joint of coal miners who work in excavation and vibration department. Forty-three coal miners with the hand-arm vibration disease served as the observation group while 20 workers who were not working in the vibration department acted as the control group. The patients in the observation group were divided into five subgroups according to the time when they received vibration. The regularity of the development of signs and symptoms of MRI was observed and analyzed. The hydroarthrosis was most found in MRI. There were significant difference in hydroarthrosis (chi(2) = 8.80, P < 0.01), osteoporosis and osteomyelitis (chi(2) = 3.91, chi(2) = 5.01, P < 0.05 respectively) between the observation group and the control group. The edema of bone marrow and the avascular necrosis of ossa carpi were found only in the observation group and not found in the control group. The hydroarthrosis and the edema of bone marrow occurred most in the early stage of vibration. The signal in the edema of the bone marrow of the distal end of the radius was decreased in the GE sequence T(2)WI with the specificity. (1) Changes in the wrist joint occur in the early stage of the vibration work, and can be found in the MRI. (2) The edema of the bone marrow of the distal end of the radius is of great value in the diagnosis of the hand-arm vibration disease.

  10. Seat vibration in military propeller aircraft: characterization, exposure assessment, and mitigation.

    PubMed

    Smith, Suzanne D

    2006-01-01

    There have been increasing reports of annoyance, fatigue, and even neck and back pain during prolonged operation of military propeller aircraft, where persistent multi-axis vibration occurs at higher frequencies beyond human whole-body resonance. This paper characterizes and assesses the higher frequency vibration transmitted to the occupants onboard these aircraft. Multi-axis accelerations were measured at the occupied seating surfaces onboard the WC/C-130J, C-130H3, and E-2C Hawkeye. The effects of the vibration were assessed in accordance with current international guidelines (ISO 2631-1:1997). The relative psychophysical effects of the frequency components and the effects of selected mitigation strategies were also investigated. The accelerations associated with the blade passage frequency measured on the passenger seat pans located on the side of the fuselage near the propeller plane of the C-130J (102 Hz) and C-130H3 (68 Hz) were noteworthy (5.19 +/- 1.72 ms(-2) rms and 7.65 +/- 0.71 ms(-2) rms, respectively, in the lateral direction of the aircraft). The psychophysical results indicated that the higher frequency component would dominate the side passengers' perception of the vibration. Balancing the props significantly reduced the lower frequency propeller rotation vibration (17 Hz), but had little effect on the blade passage frequency vibration. The relationships among the frequency, vibration direction, and seat measurement sites were complex, challenging the development of seating systems and mitigation strategies. Psychophysical metrics could provide a tool for optimizing mitigation strategies, but the current international vibration standard may not provide optimum assessment methods for evaluating higher frequency operational exposures.

  11. [The health condition of forest workers exposed to noise and vibration produced by chain saws].

    PubMed

    Malinowska-Borowska, Jolanta; Socholik, Violetta; Harazin, Barbara

    2012-01-01

    Lumberjacks' working conditions are difficult due to the presence of numerous occupational hazards. Physical factors that pose a health risk are noise and vibration produced by chain saws. Excessive exposure of lumberjacks to noise and vibration can lead to the development of hand-arm vibration syndrome and hearing loss. The aim of the work was to analyze the health condition of forestry workers exposed to occupational physical hazards. A preliminary, questionnaire-based assessment of health status was conducted in 22 chain saw operators. In a group of 15 forestry workers audiometry, vibrotactile perception thresholds and cold provocation test were performed. X-ray diagnostic imaging of upper limbs was also done. At the same time noise and vibration produced by chain saws used in forestry was measured. Vascular or neurological disorders were found in nearly half of tested workers with seniority from 2 to 20 years; 40% of the surveyed was diagnosed with hearing impairment. An 8-hour energy equivalent vibration level measured on chain saws was 4.6 m/s2. An 8-hour equivalent sound pressure level was 99.1 dB(A). The threshold limit values for noise and vibration are exceeded at woodcutters' posts. There are changes in lumberjacks' health resulting from exposure to harmful physical agents. Preventive actions are urgently needed to be addressed, especially to people employed in single-handed forestry companies.

  12. Active Vibration Control of a Railway Vehicle Carbody Using Piezoelectric Elements

    NASA Astrophysics Data System (ADS)

    Molatefi, Habibollah; Ayoubi, Pejman; Mozafari, Hozhabr

    2017-07-01

    In recent years and according to modern transportation development, rail vehicles are manufactured lighter to achieve higher speed and lower transportation costs. On the other hand, weight reduction of rail vehicles leads to increase the structural vibration. In this study, Active Vibration Control of a rail vehicle using piezoelectric elements is investigated. The optimal control employed as the control approach regard to the first two modes of vibration. A simplified Car body structure is modeled in Matlab using the finite element theory by considering six DOF beam element and then the Eigen functions and mode shapes are derived. The surface roughness of different classes of rail tracks have been obtained using random vibration theory and applied to the secondary suspension as the excitation of the structure; Then piezoelectric mounted where the greatest moments were captured. The effectiveness of Piezoelectric in structural vibrations attenuation of car body is demonstrated through the state space equations and its effect on modal coefficient.

  13. Variable-Tension-Cord Suspension/Vibration-Isolation System

    NASA Technical Reports Server (NTRS)

    Villemarette, Mark L.; Boston, Joshua; RInks, Judith; Felice, Pat; Stein, Tim; Payne, Patrick

    2006-01-01

    A system for mechanical suspension and vibration isolation of a machine or instrument is based on the use of Kevlar (or equivalent aromatic polyamide) cord held in variable tension between the machine or instrument and a surrounding frame. The basic concept of such a tensioned-cord suspension system (including one in which the cords are made of aromatic polyamide fibers) is not new by itself; what is new here is the additional provision for adjusting the tension during operation to optimize vibration- isolation properties. In the original application for which this system was conceived, the objective is to suspend a reciprocating cryocooler aboard a space shuttle and to prevent both (1) transmission of launch vibrations to the cryocooler and (2) transmission of vibrations from the cryocooler to samples in a chamber cooled by the cryocooler. The basic mechanical principle of this system can also be expected to be applicable to a variety of other systems in which there are requirements for cord suspension and vibration isolation. The reciprocating cryocooler of the original application is a generally axisymmetric object, and the surrounding frame is a generally axisymmetric object with windows (see figure). Two cords are threaded into a spoke-like pattern between attachment rings on the cryocooler, holes in the cage, and cord-tension- adjusting assemblies. Initially, the cord tensions are adjusted to at least the level necessary to suspend the cryocooler against gravitation. Accelerometers for measuring vibrations are mounted (1) on the cold tip of the cryocooler and (2) adjacent to the cage, on a structure that supports the cage. During operation, a technician observes the accelerometer outputs on an oscilloscope while manually adjusting the cord tensions in an effort to minimize the amount of vibration transmitted to and/or from the cryocooler. A contemplated future version of the system would include a microprocessor-based control subsystem that would include cord

  14. Prevalence and intensity of soil transmitted helminths among school children of Mendera Elementary School, Jimma, Southwest Ethiopia.

    PubMed

    Tefera, Ephrem; Belay, Tariku; Mekonnen, Seleshi Kebede; Zeynudin, Ahmed; Belachew, Tefera

    2017-01-01

    Soil transmitted helminths are wide spread in developing countries and in Ethiopia the prevalence of STHs varies in different parts of the country. The aim of this study was to determine the prevalence and intensity of soil transmitted helminths among school children of Mendera Elementary School Jimma town, Southwestern Ethiopia. A cross-sectional study was conducted between March 29 and April 9, 2010 to determine the prevalence and intensity of soil transmitted helminths among elementary school children. The study participants were randomly selected from class enrollment list after proportional allocation of the total sample size to each grade. Data about the background characteristics were collected using structured questionnaire. The stool samples were examined by McMaster method for the egg count which was used to determine intensity of infection. Data were analyzed using SPSS for windows version 16 and p-value less than 5% was considered as statistically significant. Of the total 715 stool specimens examined, 346 were positive for at least one intestinal parasite making the prevalence 48.4%. The most prevalent parasites were Ascaris lumbricoides 169 (23.6%) and Trichuris trichiura 165 (23.1%). The prevalence of soil transmitted helminth in this study was 45.6% (326/715). There was statistically significant difference in the prevalence of Trichuriasis between those who use latrine always and who use sometimes (p = 0.010). Females are two times more likely to be positive for Ascaris than males (p = 0.039). Majority of the students had light infection of soil transmitted helminths and none of them had heavy intensity of infection of Trichuriasis and hookworms. Nearly half of the school children were infected with at least one STHs and majority of the students had light infection of soil transmitted helminths. Students who did not wash their hands after defecation were three times more likely to be positive for Ascaris infection than those who washed their hands

  15. Prevalence and intensity of soil transmitted helminths among school children of Mendera Elementary School, Jimma, Southwest Ethiopia

    PubMed Central

    Tefera, Ephrem; Belay, Tariku; Mekonnen, Seleshi Kebede; Zeynudin, Ahmed; Belachew, Tefera

    2017-01-01

    Introduction Soil transmitted helminths are wide spread in developing countries and in Ethiopia the prevalence of STHs varies in different parts of the country. The aim of this study was to determine the prevalence and intensity of soil transmitted helminths among school children of Mendera Elementary School Jimma town, Southwestern Ethiopia. Methods A cross-sectional study was conducted between March 29 and April 9, 2010 to determine the prevalence and intensity of soil transmitted helminths among elementary school children. The study participants were randomly selected from class enrollment list after proportional allocation of the total sample size to each grade. Data about the background characteristics were collected using structured questionnaire. The stool samples were examined by McMaster method for the egg count which was used to determine intensity of infection. Data were analyzed using SPSS for windows version 16 and p-value less than 5% was considered as statistically significant. Results Of the total 715 stool specimens examined, 346 were positive for at least one intestinal parasite making the prevalence 48.4%. The most prevalent parasites were Ascaris lumbricoides 169 (23.6%) and Trichuris trichiura 165 (23.1%). The prevalence of soil transmitted helminth in this study was 45.6% (326/715). There was statistically significant difference in the prevalence of Trichuriasis between those who use latrine always and who use sometimes (p = 0.010). Females are two times more likely to be positive for Ascaris than males (p = 0.039). Majority of the students had light infection of soil transmitted helminths and none of them had heavy intensity of infection of Trichuriasis and hookworms. Conclusion Nearly half of the school children were infected with at least one STHs and majority of the students had light infection of soil transmitted helminths. Students who did not wash their hands after defecation were three times more likely to be positive for Ascaris

  16. Electrically evoked reticular lamina and basilar membrane vibrations in mice with alpha tectorin C1509G mutation

    NASA Astrophysics Data System (ADS)

    Ren, Tianying; He, Wenxuan

    2015-12-01

    Mechanical coupling between the tectorial membrane and the hair bundles of outer hair cells is crucial for stimulating mechanoelectrical transduction channels, which convert sound-induced vibrations into electrical signal, and for transmitting outer hair cell-generated force back to the basilar membrane to boost hearing sensitivity. It has been demonstrated that the detached tectorial membrane in mice with C1509G alpha tectorin mutation caused hearing loss, but enhanced electrically evoked otoacoustic emissions. To understand how the mutated cochlea emits sounds, the reticular lamina and basilar membrane vibrations were measured in the electrically stimulated cochlea in this study. The results showed that the electrically evoked basilar membrane vibration decreased dramatically while the reticular lamina vibration and otoacoustic emissions exhibited no significant change in C1509G mutation mice. This result indicates that a functional cochlear amplifier and a normal basilar membrane vibration are not required for the outer hair cell-generated sound to exit the cochlea.

  17. Responses of sympathetic nervous system to cold exposure in vibration syndrome subjects and age-matched healthy controls.

    PubMed

    Nakamoto, M

    1990-01-01

    Plasma norepinephrine and epinephrine in vibration syndrome subjects and age-matched healthy controls were measured for the purpose of estimating the responsibility of the sympathetic nervous system to cold exposure. In preliminary experiment, it was confirmed that cold air exposure of the whole body was more suitable than one-hand immersion in cold water. In the main experiment, 195 subjects were examined. Sixty-five subjects had vibration syndrome with vibration-induced white finger (VWF + group) and 65 subjects had vibration syndrome without VWF (VWF- group) and 65 controls had no symptoms (control group). In the three groups, plasma norepinephrine levels increased during cold air exposure of whole body at 7 degrees +/- 1.5 degrees C. Blood pressure increased and skin temperature decreased during cold exposure. Percent increase of norepinephrine in the VWF+ group was the highest while that in VWF- group followed and that in the control group was the lowest. This whole-body response of the sympathetic nervous system to cold conditions reflected the VWF which are characteristic symptoms of vibration syndrome. Excluding the effects of shivering and a cold feeling under cold conditions, it was confirmed that the sympathetic nervous system in vibration syndrome is activated more than in the controls. These results suggest that vibration exposure to hand and arm affects the sympathetic nervous system.

  18. Immediate effects of somatosensory stimulation on hand function in patients with poststroke hemiparesis: a randomized cross-over trial.

    PubMed

    Sim, Sun-Mi; Oh, Duck-Won; Chon, Seung-chul

    2015-12-01

    This study aimed to determine the immediate effects of somatosensory stimulation on hand function in patients with poststroke hemiparesis. Eleven patients with poststroke hemiparesis participated in this study. Four types (no stimulation, vibration, and light and rough touches) of somatosensory stimulation were performed randomly for 4 days applying only one type of somatosensory stimulation each day. The box and block test (BBT), the Jebsen-Taylor hand function test (JTHFT), hand grip strength (HGS), and movement distance and peak velocity of the wrist joint during a forward-reaching task were measured. The BBT and JTHFT scores for no stimulation [BBT: median (interquartile range), 0.00 (-1.00 to 1.00) and JTHFT: 2.57 (-0.47 to 4.92)] were significantly different from those for vibration [BBT: 3.00 (2.00-5.00) and JTHFT: -16.02 (-23.06 to -4.31)], light touch [BBT: 3.00 (1.00-4.00) and JTHFT: -5.00 (-21.20 to -0.94)], and rough touch [BBT: 2.00 (1.00-4.00) and JTHFT: -6.19 (-18.22 to -3.70)]. The JTHFT score was significantly higher for vibration than that for rough touch (P<0.05). The increase in HGS was significantly greater for light touch than that for no stimulation (P<0.05) and for vibration than that for light touch (P<0.05). There were significant differences for the sagittal and coronal planes in movement distance and for the sagittal and horizontal planes in peak velocity during the forward-reaching task (P<0.05). The findings suggest that somatosensory stimulation may be advantageous to improve the hand function of patients with poststroke hemiparesis, with more favorable effects observed in vibration stimulation.

  19. Passive and active vibration isolation systems using inerter

    NASA Astrophysics Data System (ADS)

    Alujević, N.; Čakmak, D.; Wolf, H.; Jokić, M.

    2018-03-01

    This paper presents a theoretical study on passive and active vibration isolation schemes using inerter elements in a two degree of freedom (DOF) mechanical system. The aim of the work is to discuss basic capabilities and limitations of the vibration control systems at hand using simple and physically transparent models. Broad frequency band dynamic excitation of the source DOF is assumed. The purpose of the isolator system is to prevent vibration transmission to the receiving DOF. The frequency averaged kinetic energy of the receiving mass is used as the metric for vibration isolation quality. It is shown that the use of inerter element in the passive vibration isolation scheme can enhance the isolation effect. In the active case, a feedback disturbance rejection scheme is considered. Here, the error signal is the receiving body absolute velocity which is directly fed to a reactive force actuator between the source and the receiving bodies. In such a scheme, the so-called subcritical vibration isolation problems exist. These problems are characterised by the uncoupled natural frequency of the receiving body larger than the uncoupled natural frequency of the source body. In subcritical vibration isolation problems, the performance of the active control is limited by poor stability margins. This is because the stable feedback gain is restricted in a narrow range between a minimum and a maximum. However, with the inclusion of an inerter in the isolator, one of the two stability margins can be opened. This enables large, theoretically unlimited negative feedback gains and large active damping of the receiving body vibration. A simple expression for the required inertance is derived.

  20. Active Vibration Isolation of Microgravity Experiments with Spring Umbilicals Using an Electrodynamic Actuator

    NASA Technical Reports Server (NTRS)

    Banerjee, B. B.; Allaire, P. E.; Grodsinsky, C. M.

    1996-01-01

    Microgravity experiments will require active vibration isolation in the low to mid frequency range of 0.1 Hz to 10 Hz. Approximately two orders of acceleration reduction (40 dB) will be required. Previous works have reported results for accelerations transmitted through the umbilical. This paper describes experimental and theoretical results for vibration isolation in one dimension (horizontal) where the simulated experiment is connected to the spacecraft by a spring umbilical. The experiment consisted of a spacecraft (shaker), experiment (mass), umbilical, accelerometer, control electronics, and Lorentz actuator. The experiment mass was supported in magnetic bearings to avoid any stiction problems. Acceleration feedback control was employed to obtain the vibration isolation. Three different spring umbilicals were employed. Acceleration reductions on the order of 40 dB were obtained over the frequency range of 0.1 Hz to 10 Hz. Good agreement was obtained between theory and experiment.

  1. Evaluation of the Perceptual Characteristics of a Force Induced by Asymmetric Vibrations.

    PubMed

    Tanabe, Takeshi; Yano, Hiroaki; Iwata, Hiroo

    2017-08-29

    This paper describes the properties of proprioceptive sensations induced by asymmetric vibration using a vibration speaker-type non-grounded haptic interface. We confirm that the vibration speaker generates a perceived force that pulls or pushes a user's hand in a particular direction when an asymmetric amplitude signal that is generated by inverting a part of a sine wave is input. In this paper, to verify the system with respect to various factors of force perception caused by asymmetric vibration, we conducted six experiments and the following results were obtained. (1) The force vector can be controlled by reversing the asymmetric waves. (2) By investigating the physical characteristics of the vibration, asymmetric vibration was confirmed. (3) The presentation of vibration in the shear direction on the finger pad is effective. (4) The point of subjective equality of the perceived force can be controlled by up to 0.43 N by changing the amplitude voltage of the input signals. (5) The minimum stimulation time required for force perception is 66.7 ms. (6) When the vibration is continuously presented for 40 to 50 s, the perceived force decreases because of adaptation. Hence, we confirmed that we can control both the direction and magnitude of the reaction force by changing the input signal of the vibration speaker.

  2. No Telescoping Effect with Dual Tendon Vibration

    PubMed Central

    Bellan, Valeria; Wallwork, Sarah B.; Stanton, Tasha R.; Reverberi, Carlo; Gallace, Alberto; Moseley, G. Lorimer

    2016-01-01

    The tendon vibration illusion has been extensively used to manipulate the perceived position of one’s own body part. However, findings from previous research do not seem conclusive sregarding the perceptual effect of the concurrent stimulation of both agonist and antagonist tendons over one joint. On the basis of recent data, it has been suggested that this paired stimulation generates an inconsistent signal about the limb position, which leads to a perceived shrinkage of the limb. However, this interesting effect has never been replicated. The aim of the present study was to clarify the effect of a simultaneous and equal vibration of the biceps and triceps tendons on the perceived location of the hand. Experiment 1 replicated and extended the previous findings. We compared a dual tendon stimulation condition with single tendon stimulation conditions and with a control condition (no vibration) on both ‘upward-downward’ and ‘towards-away from the elbow’ planes. Our results show a mislocalisation towards the elbow of the position of the vibrated arm during dual vibration, in line with previous results; however, this did not clarify whether the effect was due to arm representation contraction (i.e., a ‘telescoping’ effect). Therefore, in Experiment 2 we investigated explicitly and implicitly the perceived arm length during the same conditions. Our results clearly suggest that in all the vibration conditions there was a mislocalisation of the entire arm (including the elbow), but no evidence of a contraction of the perceived arm length. PMID:27305112

  3. An innovative and multi-functional smart vibration platform

    NASA Astrophysics Data System (ADS)

    Olmi, C.; Song, G.; Mo, Y. L.

    2007-08-01

    Recently, there has been increasing efforts to incorporate vibration damping or energy dissipation mechanisms into civil structures, particularly by using smart materials technologies. Although papers about structural vibration control using smart materials have been published for more than two decades, there has been little research in developing teaching equipment to introduce smart materials to students via in-classroom demonstration or hands-on experiments. In this paper, an innovative and multi-functional smart vibration platform (SVP) has been developed by the Smart Materials and Structures Laboratory at the University of Houston to demonstrate vibration control techniques using multiple smart materials for educational and research purposes. The vibration is generated by a motor with a mass imbalance mounted on top of the frame. Shape memory alloys (SMA) and magneto-rheological (MR) fluid are used to increase the stiffness and damping ratio, respectively, while a piezoceramic sensor (lead zirconate titanate, or PZT) is used as a vibration sensing device. An electrical circuit has been designed to control the platform in computer-control or manual mode through the use of knobs. The former mode allows for an automated demonstration, while the latter requires the user to manually adjust the stiffness and damping ratio of the frame. In addition, the system accepts network connections and can be used in a remote experiment via the internet. This platform has great potential to become an effective tool for teaching vibration control and smart materials technologies to students in civil, mechanical and electrical engineering for both education and research purposes.

  4. Simulation study on nitrogen vibrational and translational temperature in air breakdown plasma generated by 110 GHz focused microwave pulse

    NASA Astrophysics Data System (ADS)

    Yang, Wei; Zhou, Qianhong; Dong, Zhiwei

    2017-01-01

    We report a simulation study on nitrogen vibrational and translational temperature in 3 μs pulse 110 GHz microwave air breakdown at pressure from 1 Torr to 100 Torr. The one-dimensional model is based on a self-consistent solution to Helmholtz equation for microwave field, electron density equation, and the average energy equation for electrons, nitrogen vibrational, and translational degrees. The breakdown threshold is calculated from the transmitted microwave profile, and it agrees well with that from experiment. The spatio-temporal characteristics of vibrational and translational temperature are shown, and the peak values at the end of pulse are compared to the results fitted from optical emission spectroscopy. The dependences of vibrational and translational temperature on normalized microwave fields and gas pressure are investigated, and the underlying mechanisms are unveiled.

  5. Vibration training improves disability status in multiple sclerosis: A pretest-posttest pilot study.

    PubMed

    Yang, Feng; Estrada, Edson F; Sanchez, Maria C

    2016-10-15

    The purpose of this study was to examine the effects of an 8-week vibration training program on changing the disability level in people with multiple sclerosis (MS). Twenty-five adults with clinically-confirmed MS underwent an 8-week vibration training on a side-alternating vibration platform. The vibration frequency and peak-to-peak displacement were set at 20Hz and 2.6mm, respectively. Prior to and following the training course, the disability status was assessed for all participants characterized by the Patient Determined Disability Steps (PDDS) and MS Functional Composite (MSFC) scores. The training program significantly improved the PDDS (3.66±1.88 vs. 3.05±1.99, p=0.009) and the MSFC scores (0.00±0.62 vs 0.36±0.68, p<0.0001). All three MSFC components were improved: lower extremity function (9.37±4.92 vs. 8.13±4.08s, p=0.011), upper extremity function (dominant hand: 27.81±5.96 vs. 26.20±5.82s, p=0.053; non-dominant hand: 28.47±7.40 vs. 27.43±8.33s, p=0.059), and cognitive function (30.55±13.54 vs. 36.95±15.07 points, p=0.004). Our findings suggested that vibration training could be a promising alternative modality to reduce the disability level among people with MS. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. The Epidemiology of Soil-Transmitted Helminths in Bihar State, India

    PubMed Central

    Greenland, Katie; Dixon, Ruth; Khan, Shabbir Ali; Gunawardena, Kithsiri; Kihara, Jimmy H.; Smith, Jennifer L.; Drake, Lesley; Makkar, Prerna; Singh, Sarman; Kumar, Sanjay

    2015-01-01

    Background Soil-transmitted helminths (STHs) infect over a billion individuals worldwide. In India, 241 million children are estimated to need deworming to avert the negative consequences STH infections can have on child health and development. In February-April 2011, 17 million children in Bihar State were dewormed during a government-led school-based deworming campaign. Prior to programme implementation, a study was conducted to assess STH prevalence in the school-age population to direct the programme. The study also investigated risk factors for STH infections, including caste, literacy, and defecation and hygiene practices, in order to inform the development of complementary interventions. Methods A cross-sectional survey was conducted among children in 20 schools in Bihar. In addition to providing stool samples for identification of STH infections, children completed a short questionnaire detailing their usual defecation and hand-hygiene practices. Risk factors for STH infections were explored. Results In January-February 2011, 1279 school children aged four to seventeen provided stool samples and 1157 children also completed the questionnaire. Overall, 68% of children (10-86% across schools) were infected with one or more soil-transmitted helminth species. The prevalence of ascariasis, hookworm and trichuriasis was 52%, 42% and 5% respectively. The majority of children (95%) practiced open defecation and reported most frequently cleansing hands with soil (61%). Increasing age, lack of maternal literacy and certain castes were independently associated with hookworm infection. Absence of a hand-washing station at the schools was also independently associated with A. lumbricoides infection. Conclusions STH prevalence in Bihar is high, and justifies mass deworming in school-aged children. Open defecation is common-place and hands are often cleansed using soil. The findings reported here can be used to help direct messaging appropriate to mothers with low levels

  7. [Vibration disease: hygienic and medical aspects].

    PubMed

    Rusanova, D V; Kuleshova, M V; Katamanova, E V; Kartapoltseva, N V; Pankov, V A; Lakhman, O L; Kazakova, P V; Kuptsova, N G

    The hygienic assessment of working conditions of employees exposed to local vibration established that working conditions for employees ofvibration dangerous occupations at the aircraft plant according to the degree from a health standpoint and hazard are referred to the fourth (dangerous) class of the degree of danger that stipulates stable high levels of the morbidity rate. The leading factor is a local vibration that results in the consistently high levels of occupational morbidity rate. There was shown the efficiency of the use of the pulsed magnetic stimulation in the treatment ofpatients with vibration disease associated with the exposure to local vibration. For the evaluation of the effectiveness of treatment in patients the condition of the central nervous system was determined with the use of computer electroencephalography with the registration of visual and auditory evoked potentials and somatosensory evoked potentials; there was studied the state of the peripheral nerves in arms and legs relying upom electromyographic data; there was performed psychological study. After the performance of pulse magnetic stimulation in patients diagnosed to have the vibration diseases there were observed the improvement in the interaction of cortical-subcortical structures and associative areas of the frontal and temporal lobes of the brain. After treatment there was noted the shortening of the time of the conduction of the afferent wave of the excitation at the level of the cervical spinal cord, subcortical structures and the central conduction time. There was restored previously reduced the speed of the conduction of the impulse via the distal parts of the tibial and median nerve, through the ulnar nerve in the area of the elbow joint. There was noted the rise in the average temperature on the hands; the decline of thresholds of vibration and pain sensitivity; the improvement of indices characterizing of the state of mnestic- attentional and psycho-emotional scope of

  8. Low-frequency vibration isolation in sandwich plates by piezoelectric shunting arrays

    NASA Astrophysics Data System (ADS)

    Chen, Shengbing; Wang, Gang; Song, Yubao

    2016-12-01

    Piezoelectric shunting arrays are proposed to isolate low-frequency vibrations transmitted in sandwich plates. The performance is characterized through application of finite element method. The numerical result shows that a complete band gap, whose width is about 20 Hz, is produced in the desired low-frequency ranges. The band gap is induced by local resonances of the shunting circuits, whose location is strongly related to the inductance, while the resistance can broaden the band gap to some extent. Vibration experiments are conducted on a 1200 × 1000 × 15 mm aluminum honeycomb plate with two arrays of 5 × 5 shunted piezoelectric patches bonded on the surface panels. Significant attenuation is found in the experimental results, which agree well with the theoretical predictions. Consequently, the proposed idea is feasible and effective.

  9. Seated Occupant Apparent Mass Characteristics Under Automotive Postures and Vertical Vibration

    NASA Astrophysics Data System (ADS)

    RAKHEJA, S.; HARU, I.; BOILEAU, P.-É.

    2002-05-01

    The biodynamic apparent mass response characteristics of 24 human subjects (12 males and 12 females) seated under representative automotive postures with hands-in-lap (passengers) and hands-on-steering wheel (drivers) are reported. The measurements were carried out under white noise vertical excitations of 0·25, 0·5 and 1·0m/s2r.m.s. acceleration magnitudes in the 0·5-40Hz frequency range and a track measured input (1·07m/s2). The measured data have been analyzed to study the effects of hands position, body mass, magnitude and type of vibration excitation, and feet position, on the biodynamic response expressed in terms of apparent mass. A comparison of the measured response of subjects assuming typical automotive postures involving inclined cushion, inclined backrest and full use of backrest support with data determined under different postural conditions and excitation levels revealed considerable differences. The biodynamic response of automobile occupants seated with hands in lap, peaks in the 6·5-8·6Hz frequency range, which is considerably higher than the reported range of fundamental frequencies (4·5-5Hz) in most other studies involving different experimental conditions. The peak magnitude tends to decrease considerably for the driving posture with hands-on-steering wheel, while a second peak in the 8-12 Hz range becomes more apparent for this posture. The results suggest that biodynamic response of occupants seated in automotive seats and subject to vertical vibration need to be characterized, as a minimum, by two distinct functions for passenger and driving postures. A higher body mass, in general, yields higher peak magnitude response and lower corresponding frequency for both postures. The strong dependence of the response on the body mass is further demonstrated by grouping the measured data into four different mass ranges: less than 60 kg, between 60·5 and 70 kg, between 70·5 and 80 kg, and above 80 kg. From the results, it is concluded that

  10. WHOLE BODY VIBRATION IMPROVES ATTENTION AND MOTOR PERFORMANCE IN MICE DEPENDING ON THE DURATION OF THE WHOLE-BODY VIBRATION SESSION.

    PubMed

    Keijser, Jan N; van Heuvelen, Marieke J G; Nyakas, Csaba; Tóth, Kata; Schoemaker, Regien G; Zeinstra, Edzard; van der Zee, Eddy A

    2017-01-01

    Whole body vibration (WBV) is a form of physical stimulation via mechanical vibrations transmitted to a subject. It is assumed that WBV induces sensory stimulation in cortical brain regions through the activation of skin and muscle receptors responding to the vibration. The effects of WBV on muscle strength are well described. However, little is known about the impact of WBV on the brain. Recently, it was shown in humans that WBV improves attention in an acute WBV protocol. Preclinical research is needed to unravel the underlying brain mechanism. As a first step, we examined whether chronic WBV improves attention in mice. A custom made vibrating platform for mice with low intensity vibrations was used. Male CD1 mice (3 months of age) received five weeks WBV (30 Hz; 1.9 G), five days a week with sessions of five (n=12) or 30 (n=10) minutes. Control mice (pseudo-WBV; n=12 and 10 for the five and 30 minute sessions, respectively) were treated in a similar way, but did not receive the actual vibration. Object recognition tasks were used as an attention test (novel and spatial object recognition - the primary outcome measure). A Balance beam was used for motor performance, serving as a secondary outcome measure. WBV sessions of five (but not WBV sessions of 30 minutes) improved balance beam performance (mice gained 28% in time needed to cross the beam) and novel object recognition (mice paid significantly more attention to the novel object) as compared to pseudo WBV, but no change was found for spatial object performance (mice did not notice the relocation). Although 30 minutes WBV sessions were not beneficial, it did not impair either attention or motor performance. These results show that brief sessions of WBV improve, next to motor performance, attention for object recognition, but not spatial cues of the objects. The selective improvement of attention in mice opens the avenue to unravel the underlying brain mechanisms.

  11. Quasi-phase-matching of the dual-band nonlinear left-handed metamaterial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Yahong, E-mail: yhliu@nwpu.edu.cn; Song, Kun; Gu, Shuai

    2014-11-17

    We demonstrate a type of nonlinear meta-atom creating a dual-band nonlinear left-handed metamaterial (DNLHM). The DNLHM operates at two distinct left-handed frequency bands where there is an interval of one octave between the two center frequencies. Under the illumination of a high-power signal at the first left-handed frequency band corresponding to fundamental frequency (FF), second-harmonic generation (SHG) is observed at the second left-handed band. This means that our DNLHM supports backward-propagating waves both at FF and second-harmonic (SH) frequency. We also experimentally demonstrate quasi-phase-matching configurations for the backward SHG. This fancy parametric process can significantly transmits the SH generated bymore » an incident FF wave.« less

  12. Differences in Train-induced Vibration between Hard Soil and Soft Soil

    NASA Astrophysics Data System (ADS)

    Noyori, M.; Yokoyama, H.

    2017-12-01

    Vibration and noise caused by running trains sometimes raises environmental issues. Train-induced vibration is caused by moving static and dynamic axle loads. To reduce the vibration, it is important to clarify the conditions under which the train-induced vibration increases. In this study, we clarified the differences in train-induced vibration between on hard soil and on soft soil using a numerical simulation method. The numerical simulation method we used is a combination of two analysis. The one is a coupled vibration analysis model of a running train, a track and a supporting structure. In the analysis, the excitation force of the viaduct slabs generated by a running train is computed. The other analysis is a three-dimensional vibration analysis model of a supporting structure and the ground into which the excitation force computed by the former analysis is input. As a result of the numerical simulation, the ground vibration in the area not more than 25m from the center of the viaduct is larger under the soft soil condition than that under the hard soil condition in almost all frequency ranges. On the other hand, the ground vibration of 40 and 50Hz at a point 50m from the center of the viaduct under the hard soil condition is larger than that under the soft soil condition. These are consistent with the result of the two-dimensional FEM based on a ground model alone. Thus, we concluded that these results are obtained from not the effects of the running train but the vibration characteristics of the ground.

  13. Adaptive vibration suppression system: an iterative control law for a piezoelectric actuator shunted by a negative capacitor.

    PubMed

    Kodejska, Milos; Mokry, Pavel; Linhart, Vaclav; Vaclavik, Jan; Sluka, Tomas

    2012-12-01

    An adaptive system for the suppression of vibration transmission using a single piezoelectric actuator shunted by a negative capacitance circuit is presented. It is known that by using a negative-capacitance shunt, the spring constant of a piezoelectric actuator can be controlled to extreme values of zero or infinity. Because the value of spring constant controls a force transmitted through an elastic element, it is possible to achieve a reduction of transmissibility of vibrations through the use of a piezoelectric actuator by reducing its effective spring constant. Narrow frequency range and broad frequency range vibration isolation systems are analyzed, modeled, and experimentally investigated. The problem of high sensitivity of the vibration control system to varying operational conditions is resolved by applying an adaptive control to the circuit parameters of the negative capacitor. A control law that is based on the estimation of the value of the effective spring constant of a shunted piezoelectric actuator is presented. An adaptive system which achieves a self-adjustment of the negative capacitor parameters is presented. It is shown that such an arrangement allows the design of a simple electronic system which offers a great vibration isolation efficiency under variable vibration conditions.

  14. HTR1B gene variants associate with the susceptibility of Raynauds' phenomenon in workers exposed hand-arm vibration.

    PubMed

    Chen, Qingsong; Lang, Li; Xiao, Bin; Lin, Hansheng; Yang, Aichu; Li, Hongling; Tang, Shichuan; Huang, Hanlin

    2016-10-05

    To explore whether polymorphic variants of the HTR1B gene are associated with the susceptibility of Raynauds' Phenomenon (RP) coursed by vibration. 148 subjects exposed to vibration for more than 2 years were classified into either induced white finger (VWF) group (n = 72), or non-VWF group (n = 76). Vibration exposure levels were measured and assessed following ISO 5349-1:2001 protocol. All workers were genotyped by sequencing for the single nucleotide polymorphisms (SNPs) in the 5'-flanking and coding region of HTR1B. Genetic characteristics and linkage disequilibrium (LD) were analyzed with Haploview. Serum serotonin levels of each subject were detected using ELISA. The association between the susceptibility of vascular damage and genotype was analyzed via logistic regression. 7 known SNPs were obtained and their allele frequencies were inserted into the Hardy-Weinberg equilibrium. rs6297 variant genotype had an increased risk of VWF compared with wild genotype (OR = 2.14, 95% CI = 1.04- 4.58, P < 0.05). rs6298 mutant type (AG+GG) was found to have a significant interaction on vibration exposure LN(CEI), accounting for VWF occurrence. LN(5-HT) level is significantly different between the VWF group (x¯±s= 1.99±1.09 ng/mL) and the non-VWF group (x¯±s= 2.72±1.47 ng/mL). Serotonin levels may affect the progression of secondary RP. Polymorphic variants of the HTR1B gene are associated with the susceptibility of secondary RP in vibration-exposed occupational populations of Chinese Han people.

  15. Evaluation of a Treadmill with Vibration Isolation and Stabilization (TVIS) for Use on the International Space Station

    NASA Technical Reports Server (NTRS)

    McCrory, Jean L.; Lemmon, David R.; Sommer, H. Joseph; Prout, Brian; Smith, Damon; Korth, Deborah W.; Lucero, Javier; Greenisen, Michael; Moore, Jim

    1999-01-01

    A treadmill with vibration isolation and stabilization designed for the International Space Station (ISS) was evaluated during Shuttle mission STS-81. Three crew members ran and walked on the device, which floats freely in zero gravity. For the majority of the more than 2 hours of locomotion studied, the treadmill showed peak to peak linear and angular displacements of less than 2.5 cm and 2.5 deg, respectively. Vibration transmitted to the vehicle was within the microgravity allocation limits that are defined for the ISS. Refinements to the treadmill and harness system are discussed. This approach to treadmill design offers the possibility of generating 1G-like loads on the lower extremities while preserving the microgravity environment of the ISS for structural safety and vibration free experimental conditions.

  16. Evaluation of a Treadmill with Vibration Isolation and Stabilization (TVIS) for use on the International Space Station.

    PubMed

    McCrory, J L; Lemmon, D R; Sommer, H J; Prout, B; Smith, D; Korth, D W; Lucero, J; Greenisen, M; Moore, J; Kozlovskaya, I; Pestov, I; Stepansov, V; Miyakinchenko, Y; Cavanagh, P R

    1999-08-01

    A treadmill with vibration isolation and stabilization designed for the International Space Station (ISS) was evaluated during Shuttle mission STS-81. Three crew members ran and walked on the device, which floats freely in zero gravity. For the majority of the more than 2 hours of locomotion studied, the treadmill showed peak to peak linear and angular displacements of less than 2.5 cm and 2.5 degrees, respectively. Vibration transmitted to the vehicle was within the microgravity allocation limits that are defined for the ISS. Refinements to the treadmill and harness system are discussed. This approach to treadmill design offers the possibility of generating 1G-like loads on the lower extremities while preserving the microgravity environment of the ISS for structural safety and vibration free experimental conditions.

  17. Human response to vibration stress in Japanese workers: lessons from our 35-year studies A narrative review

    PubMed Central

    MATOBA, Tsunetaka

    2015-01-01

    The occupational uses with vibratory tools or vehicles provoked health disorders of users. We reviewed narratively our articles of 35 yr studies and their related literatures, and considered the pathophysiology of the hand-arm vibration disorders. Concerning the risk factors of health impairments in workers with vibratory tools, there are two conflicting schools of the researchers: The peripheral school emphasizes that vibration only makes predominant impairments on hands and arms, showing typically Raynaud’s phenomenon in the fingers. In the systemic school, the health disorders are produced by combination with vibration, noise and working environment, namely vibratory work itself, leading to diversified symptoms and signs in relation to systemic impairments. Our 35 yr studies have evidently supported the systemic school, including disorders of the central and autonomic nervous systems. The genesis is vibratory work itself, including vibration, noise, cold working environment, ergonomic and biodynamic conditions, and emotional stress in work. Because the health disorders yield in the whole body, the following measures would contribute to the prevention of health impairments: the attenuation of vibration and noise generated form vibratory machines and the regulations on operating tool hours. In conclusion, this occupational disease results from systemic impairments due to long-term occupational work with vibratory tools. PMID:26460379

  18. Human response to vibration stress in Japanese workers: lessons from our 35-year studies A narrative review.

    PubMed

    Matoba, Tsunetaka

    2015-01-01

    The occupational uses with vibratory tools or vehicles provoked health disorders of users. We reviewed narratively our articles of 35 yr studies and their related literatures, and considered the pathophysiology of the hand-arm vibration disorders. Concerning the risk factors of health impairments in workers with vibratory tools, there are two conflicting schools of the researchers: The peripheral school emphasizes that vibration only makes predominant impairments on hands and arms, showing typically Raynaud's phenomenon in the fingers. In the systemic school, the health disorders are produced by combination with vibration, noise and working environment, namely vibratory work itself, leading to diversified symptoms and signs in relation to systemic impairments. Our 35 yr studies have evidently supported the systemic school, including disorders of the central and autonomic nervous systems. The genesis is vibratory work itself, including vibration, noise, cold working environment, ergonomic and biodynamic conditions, and emotional stress in work. Because the health disorders yield in the whole body, the following measures would contribute to the prevention of health impairments: the attenuation of vibration and noise generated form vibratory machines and the regulations on operating tool hours. In conclusion, this occupational disease results from systemic impairments due to long-term occupational work with vibratory tools.

  19. Experimental and numerical study on vibration of the full-revolving propulsion ship stern

    NASA Astrophysics Data System (ADS)

    Liu, Chang-qing; Che, Chi-dong; Shen, Xiao-han

    2015-03-01

    In order to solve the severe vibration problems of an ocean engineering ship with a full-revolving propulsion system, the navigation tests, including forced vibration response test and modal test, are carried out in its stern. It is concluded from the comparison of the time-domain waveform and spectrum from different measurement points that three main factors lead to a high-level stern vibration. Firstly, the specific dynamic stiffness of a water tank is relatively small compared with its neighbor hold, which makes it act like a vibration isolator preventing vibrational energy transmitting to the main hold. Secondly, there exists high-density local modes in the working frequency range of the main engine and thus the local resonance occurs. Thirdly, the abnormal engagement of gears caused by the large deflection of the shaft bearing due to its low mounting rigidity leads to violent extra impulse excitations at high speeds. Then the modification against the dynamic defects is given by simply improving the specific stiffness of the water tanks. And the effect is validated by the FEM calculation. Some important experience is obtained with the problems being solved, which is useful in the design of ships with the same propulsion system. It is also believed that the dynamic consideration is as important as the static analysis for the ships, and that most of the vibration problems may be avoided with a proper acoustic design.

  20. Implementation of a robust hybrid rotary-translational vibration energy harvester for autonomous self-powered acceleration measurement

    NASA Astrophysics Data System (ADS)

    Payne, Owen R.; Vandewater, Luke A.; Ung, Chandarin; Moss, Scott D.

    2015-04-01

    In this paper, a self-powered wireless sensor node utilising ambient vibrations for power is described. The device consists of a vibration energy harvester, power management system, microcontroller, accelerometer, RF transmitter/receiver and external LED indicators. The vibration energy harvester is adapted from a previously reported hybrid rotary-translational device and uses a pair of copper coil transducers to convert the mechanical energy of a magnetic sphere into usable electricity. The device requires less than 0.8 mW of power to operate continuously in its present setup (with LED indicators off) while measuring acceleration at a sample rate of 200 Hz, with the power source providing 39.7 mW of power from 500 mg excitations at 5.5 Hz. When usable input energy is removed, the device will continue to transmit data for more than 5 minutes.

  1. Vascular and nerve damage in workers exposed to vibrating tools. The importance of objective measurements of exposure time.

    PubMed

    Gerhardsson, Lars; Balogh, Istvan; Hambert, Per-Arne; Hjortsberg, Ulf; Karlsson, Jan-Erik

    2005-01-01

    The aim of the present study was to compare the development of vibration white fingers (VWF) in workers in relation to different ways of exposure estimation, and their relationship to the standard ISO 5349, annex A. Nineteen vibration exposed (grinding machines) male workers completed a questionnaire followed by a structured interview including questions regarding their estimated hand-held vibration exposure. Neurophysiological tests such as fractionated nerve conduction velocity in hands and arms, vibrotactile perception thresholds and temperature thresholds were determined. The subjective estimation of the mean daily exposure-time to vibrating tools was 192 min (range 18-480 min) among the workers. The estimated mean exposure time calculated from the consumption of grinding wheels was 42 min (range 18-60 min), approximately a four-fold overestimation (Wilcoxon's signed ranks test, p<0.001). Thus, objective measurements of the exposure time, related to the standard ISO 5349, which in this case were based on the consumption of grinding wheels, will in most cases give a better basis for adequate risk assessment than self-exposure assessment.

  2. Hand washing for preventing diarrhoea.

    PubMed

    Ejemot, R I; Ehiri, J E; Meremikwu, M M; Critchley, J A

    2008-01-23

    Diarrhoea is a common cause of morbidity and a leading cause of death among children aged less than five years, particularly in low- and middle-income countries. It is transmitted by ingesting contaminated food or drink, by direct person-to-person contact, or from contaminated hands. Hand washing is one of a range of hygiene promotion interventions that can interrupt the transmission of diarrhoea-causing pathogens. To evaluate the effects of interventions to promote hand washing on diarrhoeal episodes in children and adults. In May 2007, we searched the Cochrane Infectious Diseases Group Specialized Register, CENTRAL (The Cochrane Library 2007, Issue 2), MEDLINE, EMBASE, LILACS, PsycINFO, Science Citation Index and Social Science Citation Index, ERIC (1966 to May 2007), SPECTR, Bibliomap, RoRe, The Grey Literature, and reference lists of articles. We also contacted researchers and organizations in the field. Randomized controlled trials, where the unit of randomization is an institution (eg day-care centre), household, or community, that compared interventions to promote hand washing or a hygiene promotion that included hand washing with no intervention to promote hand washing. Two authors independently assessed trial eligibility and methodological quality. Where appropriate, incidence rate ratios (IRR) were pooled using the generic inverse variance method and random-effects model with 95% confidence intervals (CI). Fourteen randomized controlled trials met the inclusion criteria. Eight trials were institution-based, five were community-based, and one was in a high-risk group (AIDS patients). Interventions promoting hand washing resulted in a 29% reduction in diarrhoea episodes in institutions in high-income countries (IRR 0.71, 95% CI 0.60 to 0.84; 7 trials) and a 31% reduction in such episodes in communities in low- or middle-income countries (IRR 0.69, 95% CI 0.55 to 0.87; 5 trials). Hand washing can reduce diarrhoea episodes by about 30%. This significant

  3. Transmission of helminth eggs through hands in a high-risk community.

    PubMed

    Gulliver, Francesca; Jeandron, Aurelie; Nguyen, Viet Anh; Do, Hong Anh; Ensink, Jeroen H J

    2014-10-01

    The role that hands play in the transmission of Ascaris is not well understood. A newly developed method to quantify the presence helminth eggs on hands was tested among a group of farmers in Vietnam. High turbidity in hand rinse samples meant that the adopted sugar solution had to be replaced by zinc sulphate as a flotation solution. The survey found 34% (31/90) of study participant hands' were positive for helminth eggs, though concentrations were low and ranged from 0-10 eggs/2 hands. The use of fresh excreta in agriculture was the only variable that showed an association with the concentrations of eggs found on hands. The results highlight the need to promote handwashing with soap to prevent the transmission of soil-transmitted helminth infections. © The Author 2014. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. The bio-response of osteocytes and its regulation on osteoblasts under vibration.

    PubMed

    Wu, Xin-Tong; Sun, Lian-Wen; Qi, Hong-Yu; Shi, Hao; Fan, Yu-Bo

    2016-04-01

    Vibration, especially at low magnitude and high frequency (LMHF), was demonstrated to be anabolic for bone, but how the LMHF vibration signal is perceived by osteocytes is not fully studied. On the other hand, the mechanotransduction of osteocytes under shear stress has been scientists' primary focus for years. Due to the small strain caused by low-magnitude vibration, whether the previous explanation for shear stress will still work for LMHF vibration is unknown. In this study, a finite element method (FEM) model based on the real geometrical shape of an osteocyte was built to compare the mechanical behaviors of osteocytes under LMHF vibration and shear stress. The bio-response of osteocytes to vibration under different frequencies, including the secretion of soluble factors and the concentration of intracellular calcium, were studied. The regulating effect of the conditioned medium (CM) from vibrated osteocytes on osteoblasts was also studied. The FEM analysis result showed the cell membrane deformation under LMHF vibration was very small (with a peak value of 1.09%) as compared to the deformation caused by shear stress (with a peak value of 6.65%). The F-actin stress fibers of osteocytes were reorganized, especially on the nucleus periphery after LMHF vibration. The vibration at 30 Hz has a promoting effect on osteocytes and the osteogenesis of osteoblasts, whereas vibration at 90 Hz was suppressive. These results lead to a conclusion that the bio-response of osteocytes to LMHF vibration is frequency-dependent and is more related to the cytoskeleton on nuclear periphery rather than the membrane deformation. © 2016 International Federation for Cell Biology.

  5. Electronic and vibrational exciton coupling in oxidized trianglimines.

    PubMed

    Szymkowiak, Joanna; Kwit, Marcin

    2018-02-01

    Readily available chiral trianglimine and their (poly)oxygenated congeners represent a unique class of macrocyclic rigid compounds optimal for testing electronic and vibrational circular dichroism exciton chirality methods. Electronic and vibrational circular dichroism spectra of such trianglimines are strongly affected by polar substituents in macrocycle skeletons. Double substitution by OH groups in each aromatic fragment of the macrocycle causes sign reversal of the exciton couplet in the region of the strongest UV absorption. On the other hand, electronic circular dichroism spectrum of the macrocycle having 2 methoxy groups shows 2 exciton couplets-the long-wavelength positive and the second of the negative sign, observed at the shorter wavelengths. VCD spectra of macrocyclic imines show vibrational exciton couplets in the region of strong C=N stretches. The signs of these couplets are positive and the opposite of the diamine chirality. For trianglimine macrocycles the interpretation of VCD spectra in terms of excitons is much more convincing than for electronic circular dichroism spectra. By contrast, trans-1,2-diaminocyclohexane-based vicinal diimines, being a one-third of the respective macrocycle, do not exhibit any vibrational exciton effect. Experimental data were confronted with DFT calculations. We observed good-to-excellent agreement between experimental and computed data. © 2017 Wiley Periodicals, Inc.

  6. Measurement of Vibrations in Two Tower-Typed Assistant Personal Robot Implementations with and without a Passive Suspension System

    PubMed Central

    Moreno, Javier; Clotet, Eduard; Tresanchez, Marcel; Martínez, Dani; Casanovas, Jordi; Palacín, Jordi

    2017-01-01

    This paper presents the vibration pattern measurement of two tower-typed holonomic mobile robot prototypes: one based on a rigid mechanical structure, and the other including a passive suspension system. Specific to the tower-typed mobile robots is that the vibrations that originate in the lower part of the structure are transmitted and amplified to the higher areas of the tower, causing an unpleasant visual effect and mechanical stress. This paper assesses the use of a suspension system aimed at minimizing the generation and propagation of vibrations in the upper part of the tower-typed holonomic robots. The two robots analyzed were equipped with onboard accelerometers to register the acceleration over the X, Y, and Z axes in different locations and at different velocities. In all the experiments, the amplitude of the vibrations showed a typical Gaussian pattern which has been modeled with the value of the standard deviation. The results have shown that the measured vibrations in the head of the mobile robots, including a passive suspension system, were reduced by a factor of 16. PMID:28505108

  7. A high precision ultrasonic system for vibration measurements

    NASA Astrophysics Data System (ADS)

    Young, M. S.; Li, Y. C.

    1992-11-01

    A microcomputer-aided ultrasonic system that can be used to measure the vibratory displacements of an object is presented. A pair of low cost 40-kHz ultrasonic transducers is used to transmit ultrasound toward an object and receive the ultrasound reflected from the object. The relative motion of the object modulates the phase angle difference between the transmitted and received ultrasound signals. A single-chip microcomputer-based phase detector was designed to record and analyze the phase shift information which is then sent to a PC-AT microcomputer for processing. We have developed an ingenious method to reconstruct the relative motion of an object from the acquired data of the phase difference changes. A digital plotter based experiment was also designed for testing the performance of the whole system. The measured accuracy of the system in the reported experiments is within +/- 0.4 mm and the theoretical maximal measurable speed of the object is 89.6 cm/s. The main advantages of this ultrasonic vibration measurement system are high resolution, low cost, noncontact measurement, and easy installation.

  8. Web-based interactive drone control using hand gesture

    NASA Astrophysics Data System (ADS)

    Zhao, Zhenfei; Luo, Hao; Song, Guang-Hua; Chen, Zhou; Lu, Zhe-Ming; Wu, Xiaofeng

    2018-01-01

    This paper develops a drone control prototype based on web technology with the aid of hand gesture. The uplink control command and downlink data (e.g., video) are transmitted by WiFi communication, and all the information exchange is realized on web. The control command is translated from various predetermined hand gestures. Specifically, the hardware of this friendly interactive control system is composed by a quadrotor drone, a computer vision-based hand gesture sensor, and a cost-effective computer. The software is simplified as a web-based user interface program. Aided by natural hand gestures, this system significantly reduces the complexity of traditional human-computer interaction, making remote drone operation more intuitive. Meanwhile, a web-based automatic control mode is provided in addition to the hand gesture control mode. For both operation modes, no extra application program is needed to be installed on the computer. Experimental results demonstrate the effectiveness and efficiency of the proposed system, including control accuracy, operation latency, etc. This system can be used in many applications such as controlling a drone in global positioning system denied environment or by handlers without professional drone control knowledge since it is easy to get started.

  9. Web-based interactive drone control using hand gesture.

    PubMed

    Zhao, Zhenfei; Luo, Hao; Song, Guang-Hua; Chen, Zhou; Lu, Zhe-Ming; Wu, Xiaofeng

    2018-01-01

    This paper develops a drone control prototype based on web technology with the aid of hand gesture. The uplink control command and downlink data (e.g., video) are transmitted by WiFi communication, and all the information exchange is realized on web. The control command is translated from various predetermined hand gestures. Specifically, the hardware of this friendly interactive control system is composed by a quadrotor drone, a computer vision-based hand gesture sensor, and a cost-effective computer. The software is simplified as a web-based user interface program. Aided by natural hand gestures, this system significantly reduces the complexity of traditional human-computer interaction, making remote drone operation more intuitive. Meanwhile, a web-based automatic control mode is provided in addition to the hand gesture control mode. For both operation modes, no extra application program is needed to be installed on the computer. Experimental results demonstrate the effectiveness and efficiency of the proposed system, including control accuracy, operation latency, etc. This system can be used in many applications such as controlling a drone in global positioning system denied environment or by handlers without professional drone control knowledge since it is easy to get started.

  10. High-Power Piezoelectric Vibration Characteristics of Textured SrBi2Nb2O9 Ceramics

    NASA Astrophysics Data System (ADS)

    Kawada, Shinichiro; Ogawa, Hirozumi; Kimura, Masahiko; Shiratsuyu, Kosuke; Niimi, Hideaki

    2006-09-01

    The high-power piezoelectric vibration characteristics of textured SrBi2Nb2O9 (SBN) ceramics, that is bismuth-layer-structured ferroelectrics, were studied in the longitudinal mode (33-mode) by constant current driving method and compared with those of ordinary randomly oriented SBN and widely used Pb(Ti,Zr)O3 (PZT) ceramics. In the case of textured SBN ceramics, resonant properties are stable up to a vibration velocity of 2.6 m/s. Vibration velocity at resonant frequency increases proportionally with the applied electric field, and resonant frequency is almost constant in high-vibration-velocity driving. On the other hand, in the case of randomly oriented SBN and PZT ceramics, the increase in vibration velocity is not proportional to the applied high electric field, and resonant frequency decreases with increasing vibration velocity. The resonant sharpness Q of textured SBN ceramics is about 2000, even at a vibration velocity of 2.6 m/s. Therefore, textured SBN ceramics are good candidates for high-power piezoelectric applications.

  11. Vibration parameters affecting vibration-induced reflex muscle activity.

    PubMed

    Cidem, Muharrem; Karacan, Ilhan; Cakar, Halil Ibrahim; Cidem, Mehmet; Sebik, Oguz; Yilmaz, Gizem; Turker, Kemal Sitki; Karamehmetoglu, Safak Sahir

    2017-03-01

    To determine vibration parameters affecting the amplitude of the reflex activity of soleus muscle during low-amplitude whole-body vibration (WBV). This study was conducted on 19 participants. Vibration frequencies of 25, 30, 35, 40, 45, and 50 Hz were used. Surface electromyography, collision force between vibration platform and participant's heel measured using a force sensor, and acceleration measured using an accelerometer fixed to the vibration platform were simultaneously recorded. The collision force was the main independent predictor of electromyographic amplitude. The essential parameter of vibration affecting the amplitude of the reflex muscle activity is the collision force.

  12. The physiological effects of simultaneous exposures to heat and vibration. Ph.D. Thesis - California Univ., Berkeley

    NASA Technical Reports Server (NTRS)

    Spaul, W. A.

    1983-01-01

    Determination of the effects of exposure to vibration on the body's ability to handle heat stress, and, if so, identification of the specific vibration parameters (frequency and intensity) for both whole-body (wbv) and segmental-body vibration (sbv) that would have the most detrimental effect on the body's ability to maintain thermal homeostasis were studied. Rectal and skin temperatures, heart rates, localized sweat rates, arm-segment blood perfusion rates, respiration rates, oxygen uptakes, and respiratory exchange ratios were measured in six men (22 to 33 yr) during simultaneous exposures to heat and vibration - either wbv or sbv, and during a heated 50 min recovery period. The heat conditions were T (sub db) = 43.5 + or - 0.5 C (mean + or S.E.M.), and RH = 20 + or - 4%. All vibration exposures were divided into two exposure conditions - identical frequencies but at a high intensity (HI) and a low intensity (LI) level. The HI wbv exposure was for 25 min/day at 5 Hz, 0.37 g-rms; 10 Hz, 0.46 g-rms; 16 Hz, 0.72 g-rms; 30 Hz, 1.40 g-rms; 80 Hz, 3.70 g-rms. The LI wbv exposure was for 2.5 hr/day at the same frequencies but at the following accelerations: 0.14 g-rms; 0.18 g-rms; 0.28 g-rms; 0.55 g-rms; 1.44 g-rms. During the sbv the subject stood and grasped a vibrating, in the Z-axis, hand grip with both hands.

  13. Evaluation of lumbar vertebra injury risk to the seated human body when exposed to vertical vibration

    NASA Astrophysics Data System (ADS)

    Ayari, H.; Thomas, M.; Doré, S.; Serrus, O.

    2009-03-01

    The objective of this research is to numerically determine the levels of vibration not to exceed accordingly to the corresponding dynamic stresses in the lumbar rachis when exposed to whole-body vibrations in order to identify the risk of adverse health effect to which professional heavy equipment drivers are particularly prone. A parametric finite element model of the lumbar rachis is generated in order to compute the modal parameters, the dynamic stresses and forces under harmonic excitations in a seated posture. The stress analysis reveals that the areas exposed to the highest fracture risk are the cancellous bone of the vertebral body as well as the vertebral endplate when vertical vibrations are transmitted from a seat to the lumbar spine of a driver. An injury risk factor has been developed in order to estimate the risk of adverse health effect arising from mechanical vibrations. It is shown that the injury risk factor increases with the age and consequently that the excitation amplitude must be limited to lower levels when age increases.

  14. Efficacy of Instant Hand Sanitizers against Foodborne Pathogens Compared with Hand Washing with Soap and Water in Food Preparation Settings: A Systematic Review.

    PubMed

    Foddai, Antonio C G; Grant, Irene R; Dean, Moira

    2016-06-01

    Hands can be a vector for transmitting pathogenic microorganisms to foodstuffs and drinks, and to the mouths of susceptible hosts. Hand washing is the primary barrier to prevent transmission of enteric pathogens via cross-contamination from infected persons. Conventional hand washing involves the use of water, soap, and friction to remove dirt and microorganisms. The availability of hand sanitizing products for use when water and soap are unavailable has increased in recent years. The aim of this systematic review was to collate scientific information on the efficacy of hand sanitizers compared with washing hands with soap and water for the removal of foodborne pathogens from the hands of food handlers. An extensive literature search was carried out using three electronic databases: Web of Science, Scopus, and PubMed. Twenty-eight scientific publications were ultimately included in the review. Analysis of this literature revealed various limitations in the scientific information owing to the absence of a standardized protocol for evaluating the efficacy of hand products and variation in experimental conditions. However, despite conflicting results, scientific evidence seems to support the historical skepticism about the use of waterless hand sanitizers in food preparation settings. Water and soap appear to be more effective than waterless products for removal of soil and microorganisms from hands. Alcohol-based products achieve rapid and effective inactivation of various bacteria, but their efficacy is generally lower against nonenveloped viruses. The presence of food debris significantly affects the microbial inactivation rate of hand sanitizers.

  15. Vibrational Dynamics and Guest-Host Coupling in Clathrate Hydrates

    NASA Astrophysics Data System (ADS)

    Koza, Michael M.; Schober, Helmut

    Clathrate hydrates may turn out either a blessing or a curse for mankind. On one hand, they constitute a huge reservoir of fossil fuel. On the other hand, their decomposition may liberate large amounts of green house gas and have disastrous consequences on sea floor stability. It is thus of paramount importance to understand the formation and stability of these guest-host compounds. Neutron diffraction has successfully occupied a prominent place on the stage of these scientific investigations. Complete understanding, however, is not achieved without an explanation for the thermal properties of clathrates. In particular, the thermal conductivity has a large influence on clathrate formation and conservation. Neutron spectroscopy allows probing the microscopic dynamics of clathrate hydrates. We will show how comparative studies of vibrations in clathrate hydrates give insight into the coupling of the guest to the host lattice. This coupling together with the anharmonicity of the vibrational modes is shown to lay the foundations for the peculiar thermodynamic properties of clathrate hydrates. The results obtained reach far beyond the specific clathrate system. Similar mechanisms are expected to be at work in any guest-host complex.

  16. Active vibration control of structures undergoing bending vibrations

    NASA Technical Reports Server (NTRS)

    Pla, Frederic G. (Inventor); Rajiyah, Harindra (Inventor)

    1995-01-01

    An active vibration control subassembly for a structure (such as a jet engine duct or a washing machine panel) undergoing bending vibrations caused by a source (such as the clothes agitator of the washing machine) independent of the subassembly. A piezoceramic actuator plate is vibratable by an applied electric AC signal. The plate is connected to the structure such that vibrations in the plate induced by the AC signal cause canceling bending vibrations in the structure and such that the plate is compressively pre-stressed along the structure when the structure is free of any bending vibrations. The compressive prestressing increases the amplitude of the canceling bending vibrations before the critical tensile stress level of the plate is reached. Preferably, a positive electric DC bias is also applied to the plate in its poling direction.

  17. Vibration manual

    NASA Technical Reports Server (NTRS)

    Green, C.

    1971-01-01

    Guidelines of the methods and applications used in vibration technology at the MSFC are presented. The purpose of the guidelines is to provide a practical tool for coordination and understanding between industry and government groups concerned with vibration of systems and equipments. Topics covered include measuring, reducing, analyzing, and methods for obtaining simulated environments and formulating vibration specifications. Methods for vibration and shock testing, theoretical aspects of data processing, vibration response analysis, and techniques of designing for vibration are also presented.

  18. Tremulatory and abdomen vibration signals enable communication through air in the stink bug Euschistus heros.

    PubMed

    Kavčič, Andreja; Cokl, Andrej; Laumann, Raúl A; Blassioli-Moraes, Maria Carolina; Borges, Miguel

    2013-01-01

    Communication by substrate-borne mechanical signals is widespread among animals but remains one of their least understood communication channels. Past studies of vibrational communication in insects have been oriented predominantly to communication during mating, showing that species- and sex-specific vibrational signals enable recognition and localization of potential mates on continuous solid substrates. No special attention has been paid to vibrational signals with less obvious specificity as well as to the possibility of vibrational communication across substrates that are not in physical contact. We aimed to reinvestigate emission of the aforementioned vibrational signals transmitted through a plant in the stink bug Euschistus heros (Pentatomidae: Pentatominae) and to check whether individuals are able to communicate across adjecent, physically separated substrates. We used laser vibrometry for registration of substrate-borne vibrational signals on a bean plant. Using two bean plants separated for 3 to 7 cm between two most adjacent leaves, we investigated the possibility of transmission of these signals through air. Our study showed that males and females of E. heros communicate using tremulatory, percussion and buzzing signals in addition to the previously described signals produced by vibrations of the abdomen. Contrary to the latter, the first three signal types did not differ between sexes or between pentatomid species. Experiments with two physically separated plants showed significant searching behaviour and localization of vibrational signals of an E. heros male or a female, in response to abdominal vibration produced signals of a pair duetting on the neighbouring plant, in comparison to control where no animals were on the neighbouring plant. We also confirmed that transmission through air causes amplitude and frequency decay of vibrational signals, which suggests high-amplitude, low-frequency tremulatory signals of these stink bugs their most

  19. Tremulatory and Abdomen Vibration Signals Enable Communication through Air in the Stink Bug Euschistus heros

    PubMed Central

    Kavčič, Andreja; Čokl, Andrej; Laumann, Raúl A.; Blassioli-Moraes, Maria Carolina; Borges, Miguel

    2013-01-01

    Communication by substrate-borne mechanical signals is widespread among animals but remains one of their least understood communication channels. Past studies of vibrational communication in insects have been oriented predominantly to communication during mating, showing that species- and sex-specific vibrational signals enable recognition and localization of potential mates on continuous solid substrates. No special attention has been paid to vibrational signals with less obvious specificity as well as to the possibility of vibrational communication across substrates that are not in physical contact. We aimed to reinvestigate emission of the aforementioned vibrational signals transmitted through a plant in the stink bug Euschistus heros (Pentatomidae: Pentatominae) and to check whether individuals are able to communicate across adjecent, physically separated substrates. We used laser vibrometry for registration of substrate-borne vibrational signals on a bean plant. Using two bean plants separated for 3 to 7 cm between two most adjacent leaves, we investigated the possibility of transmission of these signals through air. Our study showed that males and females of E. heros communicate using tremulatory, percussion and buzzing signals in addition to the previously described signals produced by vibrations of the abdomen. Contrary to the latter, the first three signal types did not differ between sexes or between pentatomid species. Experiments with two physically separated plants showed significant searching behaviour and localization of vibrational signals of an E. heros male or a female, in response to abdominal vibration produced signals of a pair duetting on the neighbouring plant, in comparison to control where no animals were on the neighbouring plant. We also confirmed that transmission through air causes amplitude and frequency decay of vibrational signals, which suggests high-amplitude, low-frequency tremulatory signals of these stink bugs their most

  20. Two methods for modeling vibrations of planetary gearboxes including faults: Comparison and validation

    NASA Astrophysics Data System (ADS)

    Parra, J.; Vicuña, Cristián Molina

    2017-08-01

    Planetary gearboxes are important components of many industrial applications. Vibration analysis can increase their lifetime and prevent expensive repair and safety concerns. However, an effective analysis is only possible if the vibration features of planetary gearboxes are properly understood. In this paper, models are used to study the frequency content of planetary gearbox vibrations under non-fault and different fault conditions. Two different models are considered: phenomenological model, which is an analytical-mathematical formulation based on observation, and lumped-parameter model, which is based on the solution of the equations of motion of the system. Results of both models are not directly comparable, because the phenomenological model provides the vibration on a fixed radial direction, such as the measurements of the vibration sensor mounted on the outer part of the ring gear. On the other hand, the lumped-parameter model provides the vibrations on the basis of a rotating reference frame fixed to the carrier. To overcome this situation, a function to decompose the lumped-parameter model solutions to a fixed reference frame is presented. Finally, comparisons of results from both model perspectives and experimental measurements are presented.

  1. Three Case Reports of Successful Vibration Therapy of the Plantar Fascia for Spasticity Due to Cerebral Palsy-Like Syndrome, Fetal-Type Minamata Disease

    PubMed Central

    Usuki, Fusako; Tohyama, Satsuki

    2016-01-01

    Abstract Fetal-type Minamata disease is caused by the exposure to high concentrations of methylmercury in the fetal period and shows cerebral palsy-like clinical features. Relief of spasticity is a major task of rehabilitation to improve their activities of daily living. Here we report the effect of long-term vibration therapy on bilateral lower-limb spasticity in 3 patients with fetal-type Minamata disease. We used a simple, inexpensive, and noninvasive approach with hand-held vibration massagers, which were applied to the plantar fascia at 90 Hz for 15 minutes. The effect was observed soon after the first treatment and resulted in better performance of the repetitive facilitation. Vibration therapy for 1 year improved Modified Ashworth Scale for the ankle flexors in 2 cases. The labored gait improved and gait speed increased in another case. Continued vibration therapy for another 1 year further improved Modified Ashworth Scale score and range of motion of ankle dorsiflexion in 1 case. This case showed the decreased amplitude of soleus H-reflex after the 15-minute vibration therapy, suggesting that α-motor neuron excitability was suppressed. Vibration therapy using a hand-held vibration massager may offer safe and effective treatment for lower-limb spasticity in patients with chronic neurological disorders. PMID:27082608

  2. Three Case Reports of Successful Vibration Therapy of the Plantar Fascia for Spasticity Due to Cerebral Palsy-Like Syndrome, Fetal-Type Minamata Disease.

    PubMed

    Usuki, Fusako; Tohyama, Satsuki

    2016-04-01

    Fetal-type Minamata disease is caused by the exposure to high concentrations of methylmercury in the fetal period and shows cerebral palsy-like clinical features. Relief of spasticity is a major task of rehabilitation to improve their activities of daily living. Here we report the effect of long-term vibration therapy on bilateral lower-limb spasticity in 3 patients with fetal-type Minamata disease. We used a simple, inexpensive, and noninvasive approach with hand-held vibration massagers, which were applied to the plantar fascia at 90 Hz for 15 minutes. The effect was observed soon after the first treatment and resulted in better performance of the repetitive facilitation. Vibration therapy for 1 year improved Modified Ashworth Scale for the ankle flexors in 2 cases. The labored gait improved and gait speed increased in another case. Continued vibration therapy for another 1 year further improved Modified Ashworth Scale score and range of motion of ankle dorsiflexion in 1 case. This case showed the decreased amplitude of soleus H-reflex after the 15-minute vibration therapy, suggesting that α-motor neuron excitability was suppressed. Vibration therapy using a hand-held vibration massager may offer safe and effective treatment for lower-limb spasticity in patients with chronic neurological disorders.

  3. A METHOD FOR IN-SITU CHARACTERIZATION OF RF HEATING IN PARALLEL TRANSMIT MRI

    PubMed Central

    Alon, Leeor; Deniz, Cem Murat; Brown, Ryan; Sodickson, Daniel K.; Zhu, Yudong

    2012-01-01

    In ultra high field magnetic resonance imaging, parallel radio-frequency (RF) transmission presents both opportunities and challenges for specific absorption rate (SAR) management. On one hand, parallel transmission provides flexibility in tailoring electric fields in the body while facilitating magnetization profile control. On the other hand, it increases the complexity of energy deposition as well as possibly exacerbating local SAR by improper design or delivery of RF pulses. This study shows that the information needed to characterize RF heating in parallel transmission is contained within a local power correlation matrix. Building upon a calibration scheme involving a finite number of magnetic resonance thermometry measurements, the present work establishes a way of estimating the local power correlation matrix. Determination of this matrix allows prediction of temperature change for an arbitrary parallel transmit RF pulse. In the case of a three transmit coil MR experiment in a phantom, determination and validation of the power correlation matrix was conducted in less than 200 minutes with induced temperature changes of <4 degrees C. Further optimization and adaptation are possible, and simulations evaluating potential feasibility for in vivo use are presented. The method allows general characteristics indicative of RF coil/pulse safety determined in situ. PMID:22714806

  4. Whole-body vibration exposure study in U.S. railroad locomotives--an ergonomic risk assessment.

    PubMed

    Johanning, Eckardt; Fischer, Siegfried; Christ, Eberhard; Göres, Benno; Landsbergis, Paul

    2002-01-01

    Whole-body vibration exposure of locomotive engineers and the vibration attenuation of seats in 22 U.S. locomotives (built between 1959 and 2000) was studied during normal revenue service and following international measurement guidelines. Triaxial vibration measurements (duration mean 155 min, range 84-383 min) on the seat and on the floor were compared. In addition to the basic vibration evaluation (aw rms), the vector sum (av), the maximum transient vibration value (MTVV/aw), the vibration dose value (VDV/(aw T1/4)), and the vibration seat effective transmissibility factor (SEAT) were calculated. The power spectral densities are also reported. The mean basic vibration level (aw rms) was for the fore-aft axis x = 0.18 m/sec2, the lateral axis y = 0.28 m/sec2, and the vertical axis z = 0.32 m/sec2. The mean vector sum was 0.59 m/sec2 (range 0.27 to 1.44). The crest factors were generally at or above 9 in the horizontal and vertical axis. The mean MTVV/aw was 5.3 (x), 5.1 (y), and 4.8 (z), and the VDV/(aw T1/4) values ranged from 1.32 to 2.3 (x-axis), 1.33 to 1.7 (y-axis), and 1.38 to 1.86 (z-axis), generally indicating high levels of shocks. The mean seat transmissibility factor (SEAT) was 1.4 (x) and 1.2 (y) and 1 (z), demonstrating a general ineffectiveness of any of the seat suspension systems. In conclusion, these data indicate that locomotive rides are characterized by relatively high shock content (acceleration peaks) of the vibration signal in all directions. Locomotive vertical and lateral vibrations are similar, which appears to be characteristic for rail vehicles compared with many road/off-road vehicles. Tested locomotive cab seats currently in use (new or old) appear inadequate to reduce potentially harmful vibration and shocks transmitted to the seated operator, and older seats particularly lack basic ergonomic features regarding adjustability and postural support.

  5. Hand pain other than carpal tunnel syndrome (CTS): the role of occupational factors.

    PubMed

    Andréu, José-Luis; Otón, Teresa; Silva-Fernández, Lucía; Sanz, Jesús

    2011-02-01

    Some occupational factors have been implicated in the development of disorders manifested as hand pain. The associations seem to be well documented in processes such as hand-arm vibration syndrome (HAVS) or writer's cramp. There are contradictory data in the literature about the relationships of trigger finger, De Quervain's tenosynovitis (DQT) and tenosynovitis of the wrist with occupational factors. In this article, we review current knowledge about clinical manifestations, case definition, implicated occupational factors, diagnosis and treatment of the most relevant hand pain disorders that have been associated with occupational factors, excluding carpal tunnel syndrome (CTS). Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. [Sexually transmitted coinfections. HIV coinfections].

    PubMed

    Marschalkó, Márta; Pónyai, Katinka; Kárpáti, Sarolta

    2015-01-04

    Coinfections of sexually transmitted infections are frequent due to the same transmission routes which may facilitate the transmission of other sexually transmitted infections. Sexually transmitted coinfections are associated with atypical and generally more severe clinical features, more complications, resistency to treatment, unfavourable outcome, and worse prognosis. Sexually transmitted infections may increase the likelihood of acquiring and transmission of HIV infection. The authors summarize the most important characteristics of sexually transmitted infections (such as HIV and hepatitis B virus, HIV and hepatitis C virus, HIV and syphilis, HIV and gonorrhoeae, HIV and chlamydia coinfections). These infections are more frequent in HIV infected patients than in the normal population. The shared transmission routes, impairment of the immune response, elevated cytokine levels and the associated inflammatory milieu produce local tissue damage, breaches in mucosal epithelium, which increases the risk of human immunodeficiency virus infection. Regular screening for sexually transmitted infections, use of more sensitive diagnostic methods, improved reporting and avoidance of unsafe sexual behaviour among certain subpopulations as well as education are essential in the prevention of sexually transmitted coinfections.

  7. Two-dimensional vibrational spectroscopy of the amide I band of crystalline acetanilide: Fermi resonance, conformational substates, or vibrational self-trapping?

    NASA Astrophysics Data System (ADS)

    Edler, J.; Hamm, P.

    2003-08-01

    Two-dimensional infrared (2D-IR) spectroscopy is applied to investigate acetanilide, a molecular crystal consisting of quasi-one-dimensional hydrogen bonded peptide units. The amide-I band exhibits a double peak structure, which has been attributed to different mechanisms including vibrational self-trapping, a Fermi resonance, or the existence of two conformational substates. The 2D-IR spectrum of crystalline acetanilide is compared with that of two different molecular systems: (i) benzoylchloride, which exhibits a strong symmetric Fermi resonance and (ii) N-methylacetamide dissolved in methanol which occurs in two spectroscopically distinguishable conformations. Both 2D-IR spectra differ significantly from that of crystalline acetanilide, proving that these two alternative mechanisms cannot account for the anomalous spectroscopy of crystalline acetanilide. On the other hand, vibrational self-trapping of the amide-I band can naturally explain the 2D-IR response.

  8. Transmission of Enterobius vermicularis eggs through hands of school children in rural South Africa.

    PubMed

    Cranston, Imogen; Potgieter, Natasha; Mathebula, Sammy; Ensink, Jeroen H J

    2015-10-01

    Enterobius vermicularis is a helminth that is difficult to control, is found globally, especially in crowded conditions, and can be transmitted from person to person by contaminated hands. A newly developed method for the quantification of helminth eggs on hands was tested among schoolchildren in a rural South African region to look at the role hands play in helminth infection, and to determine the risk factors for hand contamination. The study found 16.6% of participants' hands positive for helminth eggs, with E. vermicularis most commonly identified. Egg concentrations on hands ranged from 0 to 57 eggs/2 hands. Gender, toilet type used at home, and not reporting to wash hands with soap before eating were all associated with the presence of eggs on hands. The study highlights the need to improve sanitation facilities, and promote handwashing with soap in schools to prevent transmission of E. vermicularis. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  9. Portable Computer Keyboard For Use With One Hand

    NASA Technical Reports Server (NTRS)

    Friedman, Gary L.

    1992-01-01

    Data-entry device held in one hand and operated with five fingers. Contains seven keys. Letters, numbers, punctuation, and cursor commands keyed into computer by pressing keys in various combinations. Device called "data egg" used where standard typewriter keyboard unusable or unavailable. Contains micro-processor and 32-Kbyte memory. Captures text and transmits it to computer. Concept extended to computer mouse. Especially useful to handicapped or bedridden people who find it difficult or impossible to operate standard keyboards.

  10. [Features of peripheral nerve injuries in workers exposed to vibration: an analysis of 197 cases].

    PubMed

    Situ, J; Lin, C M; Qin, Z H; Zhu, D X; Lin, H; Zhang, F F; Zhang, J J

    2016-12-20

    Objective: To investigate the features of peripheral nerve injuries in workers exposed to vibration. Methods: A total of 197 male workers [median age: 34 years (21 - 50 years) ; median working years of vibration exposure: 7.3 years (1 - 20 years) ] engaged in grinding in an enterprise were enrolled. Their clinical data and electromyography results were analyzed to investigate the features of peripheral nerve impairment. Results: Of all workers, 96 (48.73%) had abnormal electromyography results. Of all workers, 88 (44.7%) had simple mild median nerve injury in the wrist, who accounted for 91.7% (88/96) of all workers with abnormal electromy-ography results. Six workers had ulnar nerve injury, superficial radial nerve injury, or/and superficial peroneal nerve injury and accounted for 6.3% of all workers with abnormal electromyography results. Of all workers, 88 had a reduced amplitude of median nerve sensory transduction, and 28 had slowed median nerve sensory transduction. A total of 46 workers were diagnosed with occupational hand-arm vibration disease and hospitalized for treatment. They were followed up for more than 4 months after leaving their jobs, and most of them showed improvements in neural electromyography results and returned to a normal state. Conclusion: Workers exposed to vibration have a high incidence rate of nerve injury in the hand, mainly sensory function impairment at the distal end of the median nerve, and all injuries are mild peripheral nerve injuries. After leaving the vibration job and being treated, most workers can achieve improvements and return to a normal state.

  11. Structural, electronic and vibrational properties of few-layer 2H-and 1T-TaSe 2

    DOE PAGES

    Yan, Jia -An; Dela Cruz, Mack A.; Cook, Brandon G.; ...

    2015-11-16

    Two-dimensional metallic transition metal dichalcogenides (TMDs) are of interest for studying phenomena such as charge-density wave (CDW) and superconductivity. Few-layer tantalum diselenides (TaSe 2) are typical metallic TMDs exhibiting rich CDW phase transitions. However, a description of the structural, electronic and vibrational properties for different crystal phases and stacking configurations, essential for interpretation of experiments, is lacking. We present first principles calculations of structural phase energetics, band dispersion near the Fermi level, phonon properties and vibrational modes at the Brillouin zone center for different layer numbers, crystal phases and stacking geometries. Evolution of the Fermi surfaces as well as themore » phonon dispersions as a function of layer number reveals dramatic dimensionality effects in this CDW material. Lastly, our results indicate strong electronic interlayer coupling, detail energetically possible stacking geometries, and provide a basis for interpretation of Raman spectra.« less

  12. Vibration transmission through sheet webs of hobo spiders (Eratigena agrestis) and tangle webs of western black widow spiders (Latrodectus hesperus).

    PubMed

    Vibert, Samantha; Scott, Catherine; Gries, Gerhard

    2016-11-01

    Web-building spiders construct their own vibratory signaling environments. Web architecture should affect signal design, and vice versa, such that vibratory signals are transmitted with a minimum of attenuation and degradation. However, the web is the medium through which a spider senses both vibratory signals from courting males and cues produced by captured prey. Moreover, webs function not only in vibration transmission, but also in defense from predators and the elements. These multiple functions may impose conflicting selection pressures on web design. We investigated vibration transmission efficiency and accuracy through two web types with contrasting architectures: sheet webs of Eratigena agrestis (Agelenidae) and tangle webs of Latrodectus hesperus (Theridiidae). We measured vibration transmission efficiencies by playing frequency sweeps through webs with a piezoelectric vibrator and a loudspeaker, recording the resulting web vibrations at several locations on each web using a laser Doppler vibrometer. Transmission efficiencies through both web types were highly variable, with within-web variation greater than among-web variation. There was little difference in transmission efficiencies of longitudinal and transverse vibrations. The inconsistent transmission of specific frequencies through webs suggests that parameters other than frequency are most important in allowing these spiders to distinguish between vibrations of prey and courting males.

  13. Experimental and Analytical Research on Resonance Phenomena of Vibrating Head with MRE Regulating Element

    NASA Astrophysics Data System (ADS)

    Miedzińska, D.; Gieleta, R.; Osiński, J.

    2015-02-01

    A vibratory pile hammer (VPH) is a mechanical device used to drive steel piles as well as tube piles into soil to provide foundation support for buildings or other structures. In order to increase the stability and the efficiency of the VPH work in the over-resonance frequency, a new VPH construction was developed at the Military University of Technology. The new VPH contains a system of counter-rotating eccentric weights, powered by hydraulic motors, and designed in such a way that horizontal vibrations cancel out, while vertical vibrations are transmitted into the pile. This system is suspended in the static parts by the adaptive variable stiffness pillows based on a smart material, magnetorheological elastomer (MRE), whose rheological and mechanical properties can be reversibly and rapidly controlled by an external magnetic field. The work presented in the paper is a part of the modified VPH construction design process. It concerns the experimental research on the vibrations during the piling process and the analytical analyses of the gained signal. The results will be applied in the VPH control system.

  14. Recovering Intrinsic Fragmental Vibrations Using the Generalized Subsystem Vibrational Analysis.

    PubMed

    Tao, Yunwen; Tian, Chuan; Verma, Niraj; Zou, Wenli; Wang, Chao; Cremer, Dieter; Kraka, Elfi

    2018-05-08

    Normal vibrational modes are generally delocalized over the molecular system, which makes it difficult to assign certain vibrations to specific fragments or functional groups. We introduce a new approach, the Generalized Subsystem Vibrational Analysis (GSVA), to extract the intrinsic fragmental vibrations of any fragment/subsystem from the whole system via the evaluation of the corresponding effective Hessian matrix. The retention of the curvature information with regard to the potential energy surface for the effective Hessian matrix endows our approach with a concrete physical basis and enables the normal vibrational modes of different molecular systems to be legitimately comparable. Furthermore, the intrinsic fragmental vibrations act as a new link between the Konkoli-Cremer local vibrational modes and the normal vibrational modes.

  15. Control of Fan Blade Vibrations Using Piezoelectrics and Bi-Directional Telemetry

    NASA Technical Reports Server (NTRS)

    Provenza, Andrew J.; Morrison, Carlos R.

    2011-01-01

    A novel wireless device which transfers supply power through induction to rotating operational amplifiers and transmits low voltage AC signals to and from a rotating body by way of radio telemetry has been successfully demonstrated in the NASA Glenn Research Center (GRC) Dynamic Spin Test Facility. In the demonstration described herein, a rotating operational amplifier provides controllable AC power to a piezoelectric patch epoxied to the surface of a rotating Ti plate. The amplitude and phase of the sinusoidal voltage command signal, transmitted wirelessly to the amplifier, was tuned to completely suppress the 3rd bending resonant vibration of the plate. The plate's 3rd bending resonance was excited using rotating magnetic bearing excitation while it spun at slow speed in a vacuum chamber. A second patch on the opposite side of the plate was used as a sensor. This paper discusses the characteristics of this novel device, the details of a spin test, results from a preliminary demonstration, and future plans.

  16. Soil-Transmitted Helminth Infections

    MedlinePlus

    ... 1.5 billion people, or 24% of the world’s population, are infected with soil-transmitted helminth infections worldwide. ... 1.5 billion people, or 24% of the world’s population, are infected with soil-transmitted helminth infections worldwide. ...

  17. Design of single-layer high-efficiency transmitting phase-gradient metasurface and high gain antenna

    NASA Astrophysics Data System (ADS)

    Zhang, Di; Yang, Xiaoqing; Su, Piqiang; Luo, Jiefang; Chen, Huijie; Yuan, Jianping; Li, Lixin

    2017-12-01

    In this paper, based on rotation phase-gradient principle, a single-layer, high-efficiency transmitting metasurface is designed and applied to high-gain antenna. In the case of circularly polarized incident wave, the PCR (polarization conversions ratio) of the metasurface element is greater than 90% in the band of 9.11-10.48 GHz. The transmitting wave emerges an anomalous refraction when left-handed circularly polarized wave are incident perpendicularly to the 1D phase-gradient metasurface, which is composed of cycle arrangement of 6 units with step value of 30°. The simulated anomalous refraction angle is 40.1°, coincided with the theoretical design value (40.6°). For further application, the 2D focused metasurface is designed to enhance the antenna performance while the left-handed circularly polarized antenna is placed at the focus. The simulated max gain is increased by 12 dB (182%) and the half-power beamwidth is reduced by 74.6°. The measured results are coincided with the simulations, which indicates the antenna has high directivity. The designed single-layer transmission metasurface has advantages of thin thickness (only 1.5 mm), high efficiency and light weight, and will have important application prospects in polarization conversion and beam control.

  18. The influence of mechanical vibration on local and central balance control.

    PubMed

    Ehsani, Hossein; Mohler, Jane; Marlinski, Vladimir; Rashedi, Ehsan; Toosizadeh, Nima

    2018-04-11

    Fall prevention has an indispensable role in enhancing life expectancy and quality of life among older adults. The first step to prevent falls is to devise reliable methods to identify individuals at high fall risk. The purpose of the current study was to assess alterations in local postural muscle and central sensory balance control mechanisms due to low-frequency externally applied vibration among elders at high fall risk, in comparison with healthy controls, as a potential tool for assessing fall risk. Three groups of participants were recruited: healthy young (n = 10; age = 23 ± 2 years), healthy elders (n = 10; age = 73 ± 3 years), and elders at high fall risk (n = 10; age = 84 ± 9 years). Eyes-open and eyes-closed upright standing balance performance was measured with no vibration, 30 Hz, and 40 Hz vibration of Gastrocnemius muscles. When vibratory stimulation was applied, changes in local-control performance manifested significant differences among the groups (p < 0.01). On average between conditions, we observed 97% and 92% less change among high fall risk participants when compared to healthy young and older adults, respectively. On the other hand, vibration-induced changes in the central-control performance were not significant between groups (p ≥ 0.19). Results suggest that local-control deficits are responsible for balance behavior alterations among elders at high fall risk and healthy individuals. This observation may be attributable to deterioration of short-latency reflexive loop in elders at high fall risk. On the other hand, we could not ascribe the balance alterations to problems related to central nervous system performance or long-latency responses. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Acoustic vibration effects in classical nucleation theory

    NASA Astrophysics Data System (ADS)

    Baird, James K.; Su, C.-H.

    2018-04-01

    Acoustic vibration is often used to improve the yield of crystals and nanoparticles growing from solutions and melts. As there is still a debate on how acoustic vibration actually works, we have examined the possibility that acoustic pressure can affect the rate of nucleation. Our method is based on an expansion of the free energy of the nucleus in powers of the acoustic pressure. With the assumption that the period of the sound wave is short as compared to the time scale for nucleation, we replace the powers of the acoustic pressure by their time averages, retaining the average of the square of the acoustic pressure as the leading term. By assuming a nucleus having spherical shape, we use the Young-Laplace equation to relate the pressure inside the nucleus to the ambient pressure. Without making further approximations not already standard in classical nucleation theory, we find that the proximate effect of acoustic pressure is to reduce both the size of the critical nucleus as well as the work required to form it from monomers. As the work serves as the activation energy, the ultimate effect of acoustic pressure is to increase the rate of nucleation. If we assume that the atomic structure of the nucleus is the same as that of an ordinary solid, however, we find the compressibility is too small for acoustic vibration effects to be noticeable. If on the other hand, we assume that the structure is similar to that of a loosely bound colloidal particle, then the effects of acoustic vibration become potentially observable.

  20. Method for enriching a middle isotope using vibration-vibration pumping

    DOEpatents

    Rich, Joseph W.; Homicz, Gregory F.; Bergman, Richard C.

    1989-01-01

    Method for producing isotopically enriched material by vibration-vibration excitation of gaseous molecules wherein a middle mass isotope of an isotopic mixture including lighter and heavier mass isotopes preferentially populates a higher vibrational mode and chemically reacts to provide a product in which it is enriched. The method can be used for vibration-vibration enrichment of .sup.17 O in a CO reactant mixture.

  1. An efficient model for coupling structural vibrations with acoustic radiation

    NASA Technical Reports Server (NTRS)

    Frendi, Abdelkader; Maestrello, Lucio; Ting, LU

    1993-01-01

    The scattering of an incident wave by a flexible panel is studied. The panel vibration is governed by the nonlinear plate equations while the loading on the panel, which is the pressure difference across the panel, depends on the reflected and transmitted waves. Two models are used to calculate this structural-acoustic interaction problem. One solves the three dimensional nonlinear Euler equations for the flow-field coupled with the plate equations (the fully coupled model). The second uses the linear wave equation for the acoustic field and expresses the load as a double integral involving the panel oscillation (the decoupled model). The panel oscillation governed by a system of integro-differential equations is solved numerically and the acoustic field is then defined by an explicit formula. Numerical results are obtained using the two models for linear and nonlinear panel vibrations. The predictions given by these two models are in good agreement but the computational time needed for the 'fully coupled model' is 60 times longer than that for 'the decoupled model'.

  2. Effects of wrist tendon vibration on targeted upper-arm movements in poststroke hemiparesis.

    PubMed

    Conrad, Megan O; Scheidt, Robert A; Schmit, Brian D

    2011-01-01

    Impaired motor control of the upper extremity after stroke may be related to lost sensory, motor, and integrative functions of the brain. Artificial activation of sensory afferents might improve control of movement by adding excitatory drive to sensorimotor control structures. The authors evaluated the effect of wrist tendon vibration (TV) on paretic upper-arm stability during point-to-point planar movements. TV (70 Hz) was applied to the forearm wrist musculature of 10 hemiparetic stroke patients as they made center-out planar arm movements. End-point stability, muscle activity, and grip pressure were compared as patients stabilized at the target position for trials completed before, during, and after the application of the vibratory stimulus. Prior to vibration, hand position fluctuated as participants attempted to maintain the hand at the target after movement termination. TV improved arm stability, as evidenced by decreased magnitude of hand tangential velocity at the target. Improved stability was accompanied by a decrease in muscle activity throughout the arm as well as a mean decrease in grip pressure. These results suggest that vibratory stimulation of the distal wrist musculature enhances stability of the proximal arm and can be studied further as a mode for improving end-point stability during reaching in hemiparetic patients.

  3. Energy transfer of highly vibrationally excited naphthalene: collisions with CHF3, CF4, and Kr.

    PubMed

    Chen Hsu, Hsu; Tsai, Ming-Tsang; Dyakov, Yuri A; Ni, Chi-Kung

    2011-08-07

    Energy transfer of highly vibrationally excited naphthalene in the triplet state in collisions with CHF(3), CF(4), and Kr was studied using a crossed-beam apparatus along with time-sliced velocity map ion imaging techniques. Highly vibrationally excited naphthalene (2.0 eV vibrational energy) was formed via the rapid intersystem crossing of naphthalene initially excited to the S(2) state by 266 nm photons. The shapes of the collisional energy-transfer probability density functions were measured directly from the scattering results of highly vibrationally excited naphthalene. In comparison to Kr atoms, the energy transfer in collisions between CHF(3) and naphthalene shows more forward scatterings, larger cross section for vibrational to translational (V → T) energy transfer, smaller cross section for translational to vibrational and rotational (T → VR) energy transfer, and more energy transferred from vibration to translation, especially in the range -ΔE(d) = -100 to -800 cm(-1). On the other hand, the difference of energy transfer properties between collisional partners Kr and CF(4) is small. The enhancement of the V → T energy transfer in collisions with CHF(3) is attributed to the large attractive interaction between naphthalene and CHF(3) (1-3 kcal/mol).

  4. Dynamic Characteristics of Buildings from Signal Processing of Ambient Vibration

    NASA Astrophysics Data System (ADS)

    Dobre, Daniela; Sorin Dragomir, Claudiu

    2017-10-01

    The experimental technique used to determine the dynamic characteristics of buildings is based on records of low intensity oscillations of the building produced by various natural factors, such as permanent agitation type microseismic motions, city traffic, wind etc. The possibility of recording these oscillations is provided by the latest seismic stations (Geosig and Kinemetrics digital accelerographs). The permanent microseismic agitation of the soil is a complex form of stationary random oscillations. The building filters the soil excitation, selects and increases the components of disruptive vibrations corresponding to its natural vibration periods. For some selected buildings, with different instrumentation schemes for the location of sensors (in free-field, at basement, ground floor, roof level), a correlation between the dynamic characteristics resulted from signal processing of ambient vibration and from a theoretical analysis will be presented. The interpretation of recording results could highlight the behavior of the whole structure. On the other hand, these results are compared with those from strong motions, or obtained from a complex dynamic analysis, and they are quite different, but they are explicable.

  5. The firing characteristics of foot sole cutaneous mechanoreceptor afferents in response to vibration stimuli.

    PubMed

    Strzalkowski, Nicholas D J; Ali, R Ayesha; Bent, Leah R

    2017-10-01

    Single unit microneurography was used to record the firing characteristics of the four classes of foot sole cutaneous afferents [fast and slowly adapting type I and II (FAI, FAII, SAI, and SAII)] in response to sinusoidal vibratory stimuli. Frequency (3-250 Hz) and amplitude (0.001-2 mm) combinations were applied to afferent receptive fields through a 6-mm diameter probe. The impulses per cycle, defined as the number of action potentials evoked per vibration sine wave, were measured over 1 s of vibration at each frequency-amplitude combination tested. Afferent entrainment threshold (lowest amplitude at which an afferent could entrain 1:1 to the vibration frequency) and afferent firing threshold (minimum amplitude for which impulses per cycle was greater than zero) were then obtained for each frequency. Increases in vibration frequency are generally associated with decreases in expected impulses per cycle ( P < 0.001), but each foot sole afferent class appears uniquely tuned to vibration stimuli. FAII afferents tended to have the lowest entrainment and firing thresholds ( P < 0.001 for both); however, these afferents seem to be sensitive across frequency. In contrast to FAII afferents, SAI and SAII afferents tended to demonstrate optimal entrainment to frequencies below 20 Hz and FAI afferents faithfully encoded frequencies between 8 and 60 Hz. Contrary to the selective activation of distinct afferent classes in the hand, application of class-specific frequencies in the foot sole is confounded due to the high sensitivity of FAII afferents. These findings may aid in the development of sensorimotor control models or the design of balance enhancement interventions. NEW & NOTEWORTHY Our work provides a mechanistic look at the capacity of foot sole cutaneous afferents to respond to vibration of varying frequency and amplitude. We found that foot sole afferent classes are uniquely tuned to vibration stimuli; however, unlike in the hand, they cannot be independently

  6. EFFECTS OF WHOLE BODY VIBRATION INTERVENTION ON HANDGRIP STRENGTH OF BRAZILIAN HEALTHY SOLDIERS.

    PubMed

    Morel, Danielle Soares; Moreira-Marconi, Eloá; Neto, Samuel Brandão Sobrinho; Domingos, Laisa Liane Paineiras; de Souza, Patrícia Lopes; Caputo, Danúbia da Cunha de Sá; Costa, Glenda Dias; de Figueiredo, Cláudia Ferreira; Carmo, Roberto Carlos Resende; de Paiva, Patrícia de Castro; Gonçalves, Cintia Renata Sousa; Kütter, Cristiane Ribeiro; de Aguiar, Eliane de Oliveira Guedes; Bernardo-Filho, Mario

    2017-01-01

    Whole body vibration (WBV) exercises have been investigated as an alternative and complementary method to traditional resistance programs for fitness improvements in healthy subjects. Active militaries must have a high fitness level and have to improve some physical abilities to accomplish some specific tasks in Army, as climb ropes, climb walls and pull up. Seven young and healthy soldiers from Brazilian Army were exposed to mechanical vibration in a push-up position, with different frequencies, as 25 (first session), 30 (second session), 35 (third session), 40 (fourth session) and 45 Hz (fifth session). The WBV intervention consisted of five WBV sessions over a consecutive two and a half-weeks period of time. A WBV session consisted of twenty bouts, each one with 10- second vibration, interspersed with 10 seconds of passive rest and 4 minutes pause after the first 10 bouts. Handgrip strength was measured, as proposed by American Society of Hand Therapists - ASHT, before and after the session using 25 Hz of frequency and 45 Hz of frequency (1 st and 5 th sessions). No significant results were found between groups. Intervention of WBV exercises with 25 and 45 Hz of frequency applied by hands of healthy and young soldiers had no significant results. Further investigations should focus on the efficacy of WBV in the improvement of handgrip strength of young and healthy people.

  7. Design of vibration isolation systems using multiobjective optimization techniques

    NASA Technical Reports Server (NTRS)

    Rao, S. S.

    1984-01-01

    The design of vibration isolation systems is considered using multicriteria optimization techniques. The integrated values of the square of the force transmitted to the main mass and the square of the relative displacement between the main mass and the base are taken as the performance indices. The design of a three degrees-of-freedom isolation system with an exponentially decaying type of base disturbance is considered for illustration. Numerical results are obtained using the global criterion, utility function, bounded objective, lexicographic, goal programming, goal attainment and game theory methods. It is found that the game theory approach is superior in finding a better optimum solution with proper balance of the various objective functions.

  8. The Development of Vibration System for Applying Magnetic Resonance Elastography (MRE) to the Supraspinatus Muscle.

    PubMed

    Ito, Daiki; Numano, Tomokazu; Mizuhara, Kazuyuki; Takamoto, Kouichi; Onishi, Takaaki; Nishijo, Hisao

    2016-01-01

    Palpation is a standard clinical tool to diagnose abnormal stiffness changes in soft tissues. However, it is difficult to palpate the supraspinatus muscle because it locates under the trapezius muscle. The magnetic resonance elastography (MRE) uses harmonic mechanical excitation to quantitatively measure the stiffness (shear modulus) of both the superficial and deep tissues. The purpose of this study was to build a vibration system for applying the MRE to the supraspinatus muscle. In this study, a power amplifier and a pneumatic pressure generator were used to supply vibrations to a vibration pad. Six healthy volunteers underwent MRE. We investigated the effects of position (the head of the humerus and the trapezius muscle) of the vibration pad on the patterns of wave propagation (wave image). When the vibration pad was placed in the trapezius muscle, the wave images represented clear wave propagation. On the other hand, when the vibration pad was placed in the head of the humerus, the wave images represented unclear wave propagation. This result might be caused by wave interferences resulting from the vibrations from bones and an intramuscular tendon of the supraspinatus muscle. The mean shear modulus also was 8.12 ± 1.83 (mean ± SD) kPa, when the vibration pad was placed in the trapezius muscle. Our results demonstrated that the vibration pad should be placed in the trapezius muscle in the MRE of the supraspinatus muscle.

  9. Variational study on the vibrational level structure and vibrational level mixing of highly vibrationally excited S₀ D₂CO.

    PubMed

    Rashev, Svetoslav; Moule, David C; Rashev, Vladimir

    2012-11-01

    We perform converged high precision variational calculations to determine the frequencies of a large number of vibrational levels in S(0) D(2)CO, extending from low to very high excess vibrational energies. For the calculations we use our specific vibrational method (recently employed for studies on H(2)CO), consisting of a combination of a search/selection algorithm and a Lanczos iteration procedure. Using the same method we perform large scale converged calculations on the vibrational level spectral structure and fragmentation at selected highly excited overtone states, up to excess vibrational energies of ∼17,000 cm(-1), in order to study the characteristics of intramolecular vibrational redistribution (IVR), vibrational level density and mode selectivity. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Optical fiber grating vibration sensor for vibration monitoring of hydraulic pump

    NASA Astrophysics Data System (ADS)

    Zhang, Zhengyi; Liu, Chuntong; Li, Hongcai; He, Zhenxin; Zhao, Xiaofeng

    2017-06-01

    In view of the existing electrical vibration monitoring traditional hydraulic pump vibration sensor, the high false alarm rate is susceptible to electromagnetic interference and is not easy to achieve long-term reliable monitoring, based on the design of a beam of the uniform strength structure of the fiber Bragg grating (FBG) vibration sensor. In this paper, based on the analysis of the vibration theory of the equal strength beam, the principle of FBG vibration tuning based on the equal intensity beam is derived. According to the practical application of the project, the structural dimensions of the equal strength beam are determined, and the optimization design of the vibrator is carried out. The finite element analysis of the sensor is carried out by ANSYS, and the first order resonant frequency is 94.739 Hz. The vibration test of the sensor is carried out by using the vibration frequency of 35 Hz and the vibration source of 50 Hz. The time domain and frequency domain analysis results of test data show that the sensor has good dynamic response characteristics, which can realize the accurate monitoring of the vibration frequency and meet the special requirements of vibration monitoring of hydraulic pump under specific environment.

  11. Safety and severity of accelerations delivered from whole body vibration exercise devices to standing adults.

    PubMed

    Muir, Jesse; Kiel, Douglas P; Rubin, Clinton T

    2013-11-01

    Whole body vibration devices are used as a means to augment training, and their potential to treat a range of musculoskeletal diseases and injuries is now being considered. The goal of this work is to determine the degree to which acceleration delivered by whole body vibration devices at the plantar surfaces of a standing human is transmitted through the axial and appendicular skeleton, and how this mechanical challenge corresponds to the safety threshold limit values established by the International Standards Organization ISO-2631. Non-blinded laboratory assessment of a range of whole body vibration devices as it pertains to acceleration transmission to healthy volunteers. Using skin and bite-bar mounted accelerometers, transmissibility to the tibia and cranium was determined in six healthy adults standing on a programmable whole body vibration device as a function of frequency and intensity. Measures of transmissibility were then made from three distinct types of whole body vibration platforms, which delivered a 50-fold range of peak-to-peak acceleration intensities (0.3-15.1 gp-p; where 1g is Earth's gravitational field). For a given frequency, transmissibility was independent of intensity when below 1g. Transmissibility declined non-linearly with increasing frequency. Depending on the whole body vibration device, vibration ranged from levels considered safe by ISO-2631 for up to 8h each day (0.3 gp-p @ 30 Hz), to levels that were seven times higher than what is considered a safe threshold for even 1 min of exposure each day (15.1 gp-p @ 30 Hz). Transmissibility to the cranium was markedly attenuated by the degree of flexion in the knees. Vibration can have adverse effects on a number of physiologic systems. This work indicates that readily accessible whole body vibration devices markedly exceed ISO guidelines for safety, and extreme caution must be practiced when considering their use. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All

  12. Frequency Up-Converted Low Frequency Vibration Energy Harvester Using Trampoline Effect

    NASA Astrophysics Data System (ADS)

    Ju, S.; Chae, S. H.; Choi, Y.; Jun, S.; Park, S. M.; Lee, S.; Lee, H. W.; Ji, C.-H.

    2013-12-01

    This paper presents a non-resonant vibration energy harvester based on magnetoelectric transduction mechanism and mechanical frequency up-conversion using trampoline effect. The harvester utilizes a freely movable spherical permanent magnet which bounces off the aluminum springs integrated at both ends of the cavity, achieving frequency up-conversion from low frequency input vibration. Moreover, bonding method of magnetoelectric laminate composite has been optimized to provide higher strain to piezoelectric material and thus obtain a higher output voltage. A proof-of-concept energy harvesting device has been fabricated and tested. Maximum open-circuit voltage of 11.2V has been obtained and output power of 0.57μW has been achieved for a 50kΩ load, when the fabricated energy harvester was hand-shaken.

  13. Nonlinear vibration absorption for a flexible arm via a virtual vibration absorber

    NASA Astrophysics Data System (ADS)

    Bian, Yushu; Gao, Zhihui

    2017-07-01

    A semi-active vibration absorption method is put forward to attenuate nonlinear vibration of a flexible arm based on the internal resonance. To maintain the 2:1 internal resonance condition and the desirable damping characteristic, a virtual vibration absorber is suggested. It is mathematically equivalent to a vibration absorber but its frequency and damping coefficients can be readily adjusted by simple control algorithms, thereby replacing those hard-to-implement mechanical designs. Through theoretical analyses and numerical simulations, it is proven that the internal resonance can be successfully established for the flexible arm, and the vibrational energy of flexible arm can be transferred to and dissipated by the virtual vibration absorber. Finally, experimental results are presented to validate the theoretical predictions. Since the proposed method absorbs rather than suppresses vibrational energy of the primary system, it is more convenient to reduce strong vibration than conventional active vibration suppression methods based on smart material actuators with limited energy output. Furthermore, since it aims to establish an internal vibrational energy transfer channel from the primary system to the vibration absorber rather than directly respond to external excitations, it is especially applicable for attenuating nonlinear vibration excited by unpredictable excitations.

  14. Numerical Calculation Method for Prediction of Ground-borne Vibration near Subway Tunnel

    NASA Astrophysics Data System (ADS)

    Tsuno, Kiwamu; Furuta, Masaru; Abe, Kazuhisa

    This paper describes the development of prediction method for ground-borne vibration from railway tunnels. Field measurement was carried out both in a subway shield tunnel, in the ground and on the ground surface. The generated vibration in the tunnel was calculated by means of the train/track/tunnel interaction model and was compared with the measurement results. On the other hand, wave propagation in the ground was calculated utilizing the empirical model, which was proposed based on the relationship between frequency and material damping coefficient α in order to predict the attenuation in the ground in consideration of frequency characteristics. Numerical calculation using 2-dimensinal FE analysis was also carried out in this research. The comparison between calculated and measured results shows that the prediction method including the model for train/track/tunnel interaction and that for wave propagation is applicable to the prediction of train-induced vibration propagated from railway tunnel.

  15. Smart mug to measure hand's geometrical mechanical impedance.

    PubMed

    Hondori, Hossein Mousavi; Tech, Ang Wei

    2011-01-01

    A novel device, which looks like a mug, has been proposed for measuring the impedance of human hand. The device is designed to have convenient size and light weight similar to an ordinary coffee mug. It contains a 2-axis inertia sensor to monitor vibration and a small motor to carry an eccentric mass (m=100 gr, r=2 cm, rpm=600). The centrifugal force due to the rotating mass applies a dynamic force to the hand that holds the mug. Correlation of the acceleration signals with the perturbing force gives the geometrical mechanical impedance. Experimental results on a healthy subject shows that impedance is posture dependant while it changes with the direction of the applied perturbing force. For nine postures the geometrical impedance is obtained all of which have elliptical shapes. The method can be used for assessment of spasticity and monitoring stability in patients with stroke or similar problems.

  16. Ocular vestibular evoked myogenic potentials elicited with vibration applied to the teeth.

    PubMed

    Parker-George, Jennifer C; Bell, Steven L; Griffin, Michael J

    2016-01-01

    This study investigated whether the method for eliciting vibration-induced oVEMPs could be improved by applying vibration directly to the teeth, and how vibration-induced oVEMP responses depend on the duration of the applied vibration. In 10 participants, a hand-held shaker was used to present 100-Hz vibration tone pips to the teeth via a customised bite-bar or to other parts of the head. oVEMP potentials were recorded in response to vibration in three orthogonal directions and five stimulus durations (10-180 ms). The oVEMP responses were analysed in terms of the peak latency onset, peak-to-peak amplitude, and the quality of the trace. Vibration applied to the teeth via the bite-bar produced oVEMPs that were more consistent, of higher quality and of greater amplitude than those evoked by vibration applied to the head. Longer duration stimuli produced longer duration oVEMP responses. One cycle duration stimuli produced responses that were smaller in amplitude and lower quality than the longer stimulus durations. Application of vibration via the teeth using a bite-bar is an effective means of producing oVEMPs. A 1-cycle stimulus is not optimal to evoke an oVEMP because it produces less robust responses than those of longer stimulus duration. A positive relationship between the duration of the stimulus and the response is consistent with the notion that the vibration-induced oVEMP is an oscillatory response to the motion of the head, rather than being a simple reflex response that occurs when the stimulus exceeds a threshold level of stimulation. Applying acceleration to the teeth through a bite-bar elicits clearer oVEMP responses than direct application to other parts of the head and has potential to improve clinical measurements. A 100-Hz 1-cycle stimulus produces less robust oVEMP responses than longer 100-Hz stimuli. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  17. Detection of atomic force microscopy cantilever displacement with a transmitted electron beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wagner, R.; Woehl, T. J.; Keller, R. R.

    2016-07-25

    The response time of an atomic force microscopy (AFM) cantilever can be decreased by reducing cantilever size; however, the fastest AFM cantilevers are currently nearing the smallest size that can be detected with the conventional optical lever approach. Here, we demonstrate an electron beam detection scheme for measuring AFM cantilever oscillations. The oscillating AFM tip is positioned perpendicular to and in the path of a stationary focused nanometer sized electron beam. As the tip oscillates, the thickness of the material under the electron beam changes, causing a fluctuation in the number of scattered transmitted electrons that are detected. We demonstratemore » detection of sub-nanometer vibration amplitudes with an electron beam, providing a pathway for dynamic AFM with cantilevers that are orders of magnitude smaller and faster than the current state of the art.« less

  18. Prevalence of vibration-induced white finger in fluorspar mines in Weardale.

    PubMed Central

    Chatterjee, D S; Petrie, A; Taylor, W

    1978-01-01

    A combined epidemiological and clinical study of vibration-induced white finger (VWF) was carried out involving 115 men in four fluorspar mines. The overall prevalence of VWF was found to be 50% among 42 vibration-exposed subjects, while that of constitutional white finger (CWF) was 5-6% in all men studied. The VWF latent interval was 1-19 years with a mean of 5-6 years. An association was observed between the exposure time and VWF stages which included 18 men in Stage 0, three in the intermediate Stage of 0T/0N, five in Stage 2 and 16 in Stage 3; no men were seen at Stage 1. Among those with VWF in Stage 3, the index, middle and ring fingers were affected in both hands and the little fingers and thumbs were last to be involved. Clinically, on general examination, apart from vibration-induced white finger, the men in the 'vibration' group were not as healthy as those in the 'control' group. The circumference of the index fingers was not significantly different for the different groups. Neurological tests showed that the ridge test and, to a lesser extent, the two-point discrimination and the light touch tests, could be regarded as useful for the diagnosis of VWF. PMID:698134

  19. Compensated vibrating optical fiber pressure measuring device

    DOEpatents

    Fasching, George E.; Goff, David R.

    1987-01-01

    A microbending optical fiber is attached under tension to a diaphragm to se a differential pressure applied across the diaphragm which it causes it to deflect. The fiber is attached to the diaphragm so that one portion of the fiber, attached to a central portion of the diaphragm, undergoes a change in tension; proportional to the differential pressure applied to the diaphragm while a second portion attached at the periphery of the diaphragm remains at a reference tension. Both portions of the fiber are caused to vibrate at their natural frequencies. Light transmitted through the fiber is attenuated by both portions of the tensioned sections of the fiber by an amount which increases with the curvature of fiber bending so that the light signal is modulated by both portions of the fiber at separate frequencies. The modulated light signal is transduced into a electrical signal. The separate modulation signals are detected to generate separate signals having frequencies corresponding to the reference and measuring vibrating sections of the continuous fiber, respectively. A signal proportional to the difference between these signals is generated which is indicative of the measured pressure differential across the diaphragm. The reference portion of the fiber is used to compensate the pressure signal for zero and span changes resulting from ambient temperature and humidity effects upon the fiber and the transducer fixture.

  20. Proposal to use vibration analysis steering components and car body to monitor, for example, the state of unbalance wheel

    NASA Astrophysics Data System (ADS)

    Janczur, R.

    2016-09-01

    The results of road tests of car VW Passat equipped with tires of size 195/65 R15, on the influence of the unbalancing front wheel on vibration of the parts of steering system, steering wheel and the body of the vehicle have been presented in this paper. Unbalances wheels made using weights of different masses, placed close to the outer edge of the steel rim and checked on the machine Hunter GSP 9700 for balancing wheels. The recorded waveforms vibration steering components and car body, at different constant driving speeds, subjected to spectral analysis to determine the possibility of isolating vibration caused by unbalanced wheel in various states and coming from good quality asphalt road surface. The results were discussed in terms of the possibility of identifying the state of unbalancing wheels and possible changes in radial stiffness of the tire vibration transmitted through the system driving wheel on the steering wheel. Vibration analysis steering components and car body, also in the longitudinal direction, including information from the CAN bus of the state of motion of the car, can be used to monitor the development of the state of unbalance wheel, tire damage or errors shape of brake discs or brake drums, causing pulsations braking forces.

  1. Communication: Creation of molecular vibrational motions via the rotation-vibration coupling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shu, Chuan-Cun; School of Engineering and Information Technology, University of New South Wales at the Australian Defence Force Academy, Canberra, ACT 2600; Henriksen, Niels E., E-mail: neh@kemi.dtu.dk

    2015-06-14

    Building on recent advances in the rotational excitation of molecules, we show how the effect of rotation-vibration coupling can be switched on in a controlled manner and how this coupling unfolds in real time after a pure rotational excitation. We present the first examination of the vibrational motions which can be induced via the rotation-vibration coupling after a pulsed rotational excitation. A time-dependent quantum wave packet calculation for the HF molecule shows how a slow (compared to the vibrational period) rotational excitation leads to a smooth increase in the average bond length whereas a fast rotational excitation leads to amore » non-stationary vibrational motion. As a result, under field-free postpulse conditions, either a stretched stationary bond or a vibrating bond can be created due to the coupling between the rotational and vibrational degrees of freedom. The latter corresponds to a laser-induced breakdown of the adiabatic approximation for rotation-vibration coupling.« less

  2. Multi-Sensor Systems Development for UXO Detection and Discrimination: Hand-Held Dual Magnetic/Electromagnetic Induction Sensor

    DTIC Science & Technology

    2008-04-01

    5 Fluxgate magnetometer ... magnetometer into digital format, and transmitted as a single serial data string to log the Cs and fluxgate magnetometer data. After procurement...Hardware The system hardware comprises an EMI sensor, Cs vapor magnetometer , fluxgate magnetometer , hand-held data acquisition computer, integrated

  3. Hands-free device control using sound picked up in the ear canal

    NASA Astrophysics Data System (ADS)

    Chhatpar, Siddharth R.; Ngia, Lester; Vlach, Chris; Lin, Dong; Birkhimer, Craig; Juneja, Amit; Pruthi, Tarun; Hoffman, Orin; Lewis, Tristan

    2008-04-01

    Hands-free control of unmanned ground vehicles is essential for soldiers, bomb disposal squads, and first responders. Having their hands free for other equipment and tasks allows them to be safer and more mobile. Currently, the most successful hands-free control devices are speech-command based. However, these devices use external microphones, and in field environments, e.g., war zones and fire sites, their performance suffers because of loud ambient noise: typically above 90dBA. This paper describes the development of technology using the ear as an output source that can provide excellent command recognition accuracy even in noisy environments. Instead of picking up speech radiating from the mouth, this technology detects speech transmitted internally through the ear canal. Discreet tongue movements also create air pressure changes within the ear canal, and can be used for stealth control. A patented earpiece was developed with a microphone pointed into the ear canal that captures these signals generated by tongue movements and speech. The signals are transmitted from the earpiece to an Ultra-Mobile Personal Computer (UMPC) through a wired connection. The UMPC processes the signals and utilizes them for device control. The processing can include command recognition, ambient noise cancellation, acoustic echo cancellation, and speech equalization. Successful control of an iRobot PackBot has been demonstrated with both speech (13 discrete commands) and tongue (5 discrete commands) signals. In preliminary tests, command recognition accuracy was 95% with speech control and 85% with tongue control.

  4. [A study on the thermographic diagnosis of vibration disease of tie-tamper operators in the Japanese National Railways].

    PubMed

    Hirahata, H

    1984-01-01

    There have been many studies of thermographic diagnosis of vibration disease, but few of them seem to have discussed tie-tamping machines as a cause. This study focuses on thermographic diagnosis of vibration disease in tie-tamper operators of the Japanese National Railways. In the diagnosis the subject's both hands were immersed in water at 10 degrees C for 3 minutes before being examined. Variables such as season, age, type of vibration tool used and total operating time were considered. These were selected as outside variables and thermographic results as dependent variables, in Quantification Method II. Season and confirmation of vibration disease were found to have a relationship to thermographic scaling, but no such relationship was found for age, type of vibration tool used, or total operating time. A cross-analysis of variables confirmed the relationship with season, and revealed that there were fewer confirmed cases of vibration disease in spring and summer than in fall and winter. It was finally concluded that thermographic analysis is more reliable in colder weather.

  5. Is intrasound vibration useful in the diagnosis of occult scaphoid fractures?

    PubMed

    Roolker, L; Tiel-van Buul, M M; Broekhuizen, T H

    1998-03-01

    This study was designed to confirm the results of Finkenberg et al. (J Hand Surg 1993;18A: 4-7), who found a high sensitivity (100%) and specificity (95%) of the intrasound vibration method in diagnosing occult scaphoid fractures. These occult scaphoid fractures are not visible on x-ray films, but clinically the patients are suspected of having a scaphoid fracture. A vibratory apparatus is placed over the anatomical snuff-box and a vibration of 100 mW is emitted; a painful sensation is produced if the scaphoid is fractured. Thirty-seven consecutive patients with a clinically suspected scaphoid fracture were evaluated. In 6 patients, a scaphoid fracture was radiographically identified; in the remaining 31 patients, a 3-phase bone scan was obtained. Eleven wrists showed increased uptake over the scaphoid and were considered to have an occult scaphoid fracture. In this group, bone scintigraphy was used as the reference standard. The vibration test was painful in 1 of 6 patients with a proven scaphoid fracture and in 3 of the 11 patients with a positive bone scan. In contrast to the results of Finkenberg et al, the intrasound vibration method shows a sensitivity of 24%, a specificity of 85%, a positive predictive value of 40%, and a negative predictive value of 65%. We conclude that the accuracy of intrasound vibration is low and that it is not useful in the diagnosis of scaphoid fractures.

  6. TRANSMIT system evaluation : final report

    DOT National Transportation Integrated Search

    1998-06-30

    This report presents the evaluation results of TRANSCOMs System for Managing Incidents and Traffic (TRANSMIT). The TRANSMIT system utilizes Electronic Toll and Traffic Management (ETTM) equipment, which is compatible with the E-Z Pass system, for ...

  7. Statistics, Uncertainty, and Transmitted Variation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wendelberger, Joanne Roth

    2014-11-05

    The field of Statistics provides methods for modeling and understanding data and making decisions in the presence of uncertainty. When examining response functions, variation present in the input variables will be transmitted via the response function to the output variables. This phenomenon can potentially have significant impacts on the uncertainty associated with results from subsequent analysis. This presentation will examine the concept of transmitted variation, its impact on designed experiments, and a method for identifying and estimating sources of transmitted variation in certain settings.

  8. Incorporating nuclear vibrational energies into the "atom in molecules" analysis: An analytical study

    NASA Astrophysics Data System (ADS)

    Gharabaghi, Masumeh; Shahbazian, Shant

    2017-04-01

    The quantum theory of atoms in molecules (QTAIM) is based on the clamped nucleus paradigm and solely working with the electronic wavefunctions, so does not include nuclear vibrations in the AIM analysis. On the other hand, the recently extended version of the QTAIM, called the multi-component QTAIM (MC-QTAIM), incorporates both electrons and quantum nuclei, i.e., those nuclei treated as quantum waves instead of clamped point charges, into the AIM analysis using non-adiabatic wavefunctions. Thus, the MC-QTAIM is the natural framework to incorporate the role of nuclear vibrations into the AIM analysis. In this study, within the context of the MC-QTAIM, the formalism of including nuclear vibrational energy in the atomic basin energy is developed in detail and its contribution is derived analytically using the recently proposed non-adiabatic Hartree product nuclear wavefunction. It is demonstrated that within the context of this wavefunction, the quantum nuclei may be conceived pseudo-adiabatically as quantum oscillators and both isotropic harmonic and anisotropic anharmonic oscillator models are used to compute the zero-point nuclear vibrational energy contribution to the basin energies explicitly. Inspired by the results gained within the context of the MC-QTAIM analysis, a heuristic approach is proposed within the context of the QTAIM to include nuclear vibrational energy in the basin energy from the vibrational wavefunction derived adiabatically. The explicit calculation of the basin contribution of the zero-point vibrational energy using the uncoupled harmonic oscillator model leads to results consistent with those derived from the MC-QTAIM.

  9. Incorporating nuclear vibrational energies into the "atom in molecules" analysis: An analytical study.

    PubMed

    Gharabaghi, Masumeh; Shahbazian, Shant

    2017-04-21

    The quantum theory of atoms in molecules (QTAIM) is based on the clamped nucleus paradigm and solely working with the electronic wavefunctions, so does not include nuclear vibrations in the AIM analysis. On the other hand, the recently extended version of the QTAIM, called the multi-component QTAIM (MC-QTAIM), incorporates both electrons and quantum nuclei, i.e., those nuclei treated as quantum waves instead of clamped point charges, into the AIM analysis using non-adiabatic wavefunctions. Thus, the MC-QTAIM is the natural framework to incorporate the role of nuclear vibrations into the AIM analysis. In this study, within the context of the MC-QTAIM, the formalism of including nuclear vibrational energy in the atomic basin energy is developed in detail and its contribution is derived analytically using the recently proposed non-adiabatic Hartree product nuclear wavefunction. It is demonstrated that within the context of this wavefunction, the quantum nuclei may be conceived pseudo-adiabatically as quantum oscillators and both isotropic harmonic and anisotropic anharmonic oscillator models are used to compute the zero-point nuclear vibrational energy contribution to the basin energies explicitly. Inspired by the results gained within the context of the MC-QTAIM analysis, a heuristic approach is proposed within the context of the QTAIM to include nuclear vibrational energy in the basin energy from the vibrational wavefunction derived adiabatically. The explicit calculation of the basin contribution of the zero-point vibrational energy using the uncoupled harmonic oscillator model leads to results consistent with those derived from the MC-QTAIM.

  10. Vibration Analysis of a Tire in Ground Contact under Varied Conditions

    NASA Astrophysics Data System (ADS)

    Karakus, Murat; Cavus, Aydin; Colakoglu, Mehmet

    2017-03-01

    The effect of three different factors, which are inflation pressure, vertical load and coefficient of friction on the natural frequencies of a tire (175/70 R13) has been studied. A three dimensional tire model is constructed, using four different material properties and parts in the tire. Mechanical properties of the composite parts are evaluated. After investigating the free vibration, contact analysis is carried out. A concrete block and the tire are modelled together, using three different coefficients of friction. Experiments are run under certain conditions to check the accuracy of the numerical model. The natural frequencies are measured to describe free vibration and vibration of the tire contacted by ground, using a damping monitoring method. It is seen, that experimental and numerical results are in good agreement. On the other hand, investigating the impact of three different factors together is quite difficult on the natural frequencies. When some of these factors are assumed to be constant and the variables are taken one by one, it is easier to assess the effects.

  11. EFFECTS OF WHOLE BODY VIBRATION INTERVENTION ON HANDGRIP STRENGTH OF BRAZILIAN HEALTHY SOLDIERS

    PubMed Central

    Morel, Danielle Soares; Moreira-Marconi, Eloá; Neto, Samuel Brandão Sobrinho; Domingos, Laisa Liane Paineiras; de Souza, Patrícia Lopes; Caputo, Danúbia da Cunha de Sá; Costa, Glenda Dias; de Figueiredo, Cláudia Ferreira; Carmo, Roberto Carlos Resende; de Paiva, Patrícia de Castro; Gonçalves, Cintia Renata Sousa; Kütter, Cristiane Ribeiro; de Aguiar, Eliane de Oliveira Guedes; Bernardo-Filho, Mario

    2017-01-01

    Background: Whole body vibration (WBV) exercises have been investigated as an alternative and complementary method to traditional resistance programs for fitness improvements in healthy subjects. Active militaries must have a high fitness level and have to improve some physical abilities to accomplish some specific tasks in Army, as climb ropes, climb walls and pull up. Materials and methods: Seven young and healthy soldiers from Brazilian Army were exposed to mechanical vibration in a push-up position, with different frequencies, as 25 (first session), 30 (second session), 35 (third session), 40 (fourth session) and 45 Hz (fifth session). The WBV intervention consisted of five WBV sessions over a consecutive two and a half-weeks period of time. A WBV session consisted of twenty bouts, each one with 10- second vibration, interspersed with 10 seconds of passive rest and 4 minutes pause after the first 10 bouts. Handgrip strength was measured, as proposed by American Society of Hand Therapists – ASHT, before and after the session using 25 Hz of frequency and 45 Hz of frequency (1st and 5th sessions). Results: No significant results were found between groups. Conclusion: Intervention of WBV exercises with 25 and 45 Hz of frequency applied by hands of healthy and young soldiers had no significant results. Further investigations should focus on the efficacy of WBV in the improvement of handgrip strength of young and healthy people. PMID:28740941

  12. Investigation on the effect of MR elastomer based adaptive vibration absorbers on the radiated sound from circular elastic plates

    NASA Astrophysics Data System (ADS)

    Hemmatian, M.; Sedaghati, R.

    2016-04-01

    This study aims to investigate the effect of using magnetorheological elastomer (MRE)-based adaptive tuned vibration absorbers (ATVA) on the sound transmission in an elastic plate. Sound transmission loss (STL) of an elastic circular thin plate is analytically studied. The plate is excited by a plane acoustic wave as an incident sound and the displacement of the plate is calculated using corresponding mode shapes of the system for clamped boundary condition. Rayleigh integral approach is used to express the transmitted sound pressure in terms of the plate's displacement modal amplitude. In order to increase sound transmission loss of the plate, the MRE-based ATVA is considered. The basic idea is to be able to change the stiffness of the ATVA by varying magnetic field in order to reduce the transmitted acoustic energy of the host structure in a wide frequency range. Here, a MRE-based ATVA under the shear mode consisting of an oscillator mass, magnetic conductor, coils and MRE is investigated. In order to predict the viscoelastic characteristics of the field-dependent MRE based on the applied magnetic field, the double pole model is used. Finally, MRE-based ATVAs are integrated with the plate to absorb the plate energy with the aim of decreasing the transmitted sound power. Results show that plate with integrated MRE-based ATVAs suppresses the axisymmetric vibration of the plate and thus considerably improves the STL. Parametric studies on the influence of the position of MRE-based ATVAs and the effects of applied current on their performance are also presented.

  13. Measurement of ground and nearby building vibration and noise induced by trains in a metro depot.

    PubMed

    Zou, Chao; Wang, Yimin; Wang, Peng; Guo, Jixing

    2015-12-01

    Metro depots are where subway trains are parked and where maintenance is carried out. They usually occupy the largest ground areas in metro projects. Due to land utilization problems, Chinese cities have begun to develop over-track buildings above metro depots for people's life and work. The frequently moving trains, when going into and out of metro depots, can cause excessive vibration and noise to over-track buildings and adversely affect the living quality of the building occupants. Considering the current need of reliable experimental data for the construction of metro depots, field measurements of vibration and noise on the ground and inside a nearby 3-story building subjected to moving subway trains were conducted in a metro depot at Guangzhou, China. The amplitudes and frequency contents of velocity levels were quantified and compared. The composite A-weighted equivalent sound levels and maximum sound levels were captured. The predicted models for vibration and noise of metro depot were proposed based on existing models and verified. It was found that the vertical vibrations were significantly greater than the horizontal vibrations on the ground and inside the building near the testing line. While at the throat area, the horizontal vibrations near the curved track were remarkably greater than the vertical vibrations. The attenuation of the vibrations with frequencies above 50 Hz was larger than the ones below 50 Hz, and the frequencies of vibration transmitting to adjacent buildings were mainly within 10-50 Hz. The largest equivalent sound level generated in the throat area was smaller than the testing line one, but the instantaneous maximum sound level induced by wheels squeal, contact between wheels and rail joints as well as turnout was close to or even greater than the testing line one. The predicted models gave a first estimation for design and assessment of newly built metro depots. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. An MRI-compatible hand sensory vibrotactile system.

    PubMed

    Wang, Fa; Lakshminarayanan, Kishor; Slota, Gregory P; Seo, Na Jin; Webster, John G

    2015-01-01

    Recently, the application of vibrotactile noise to the wrist or back of the hand has been shown to enhance fingertip tactile sensory perception (Enders et al 2013), supporting the potential for an assistive device worn at the wrist, that generates minute vibrations to help the elderly or patients with sensory deficit. However, knowledge regarding the detailed physiological mechanism behind this sensory improvement in the central nervous system, especially in the human brain, is limited, hindering progress in development and use of such assistive devices. To enable investigation of the impact of vibrotactile noise on sensorimotor brain activity in humans, a magnetic resonance imaging (MRI)-compatible vibrotactile system was developed to provide vibrotactile noise during an MRI of the brain. The vibrotactile system utilizes a remote (outside the MR room) signal amplifier which provides a voltage from -40 to +40 V to drive a 12 mm diameter piezoelectric vibrator (inside the MR room). It is portable and is found to be MRI-compatible which enables its use for neurologic investigation with MRI. The system was also found to induce an improvement in fingertip tactile sensation, consistent with the previous study.

  15. 2012 Sexually Transmitted Diseases Surveillance, Other Sexually Transmitted Diseases

    MedlinePlus

    ... 2012 Sexually Transmitted Diseases Surveillance Table of Contents Introductory Section Foreword Preface Acronyms Figures- National Profile Figures - ... GISP Profiles Related Links STD Home STD Data & Statistics NCHHSTP Atlas Interactive STD Data - 1996-2013 STD ...

  16. High fidelity quantum gates with vibrational qubits.

    PubMed

    Berrios, Eduardo; Gruebele, Martin; Shyshlov, Dmytro; Wang, Lei; Babikov, Dmitri

    2012-11-26

    Physical implementation of quantum gates acting on qubits does not achieve a perfect fidelity of 1. The actual output qubit may not match the targeted output of the desired gate. According to theoretical estimates, intrinsic gate fidelities >99.99% are necessary so that error correction codes can be used to achieve perfect fidelity. Here we test what fidelity can be accomplished for a CNOT gate executed by a shaped ultrafast laser pulse interacting with vibrational states of the molecule SCCl(2). This molecule has been used as a test system for low-fidelity calculations before. To make our test more stringent, we include vibrational levels that do not encode the desired qubits but are close enough in energy to interfere with population transfer by the laser pulse. We use two complementary approaches: optimal control theory determines what the best possible pulse can do; a more constrained physical model calculates what an experiment likely can do. Optimal control theory finds pulses with fidelity >0.9999, in excess of the quantum error correction threshold with 8 × 10(4) iterations. On the other hand, the physical model achieves only 0.9992 after 8 × 10(4) iterations. Both calculations converge as an inverse power law toward unit fidelity after >10(2) iterations/generations. In principle, the fidelities necessary for quantum error correction are reachable with qubits encoded by molecular vibrations. In practice, it will be challenging with current laboratory instrumentation because of slow convergence past fidelities of 0.99.

  17. Prediction and measurements of vibrations from a railway track lying on a peaty ground

    NASA Astrophysics Data System (ADS)

    Picoux, B.; Rotinat, R.; Regoin, J. P.; Le Houédec, D.

    2003-10-01

    This paper introduces a two-dimensional model for the response of the ground surface due to vibrations generated by a railway traffic. A semi-analytical wave propagation model is introduced which is subjected to a set of harmonic moving loads and based on a calculation method of the dynamic stiffness matrix of the ground. In order to model a complete railway system, the effect of a simple track model is taken into account including rails, sleepers and ballast especially designed for the study of low vibration frequencies. The priority has been given to a simple formulation based on the principle of spatial Fourier transforms compatible with good numerical efficiency and yet providing quick solutions. In addition, in situ measurements for a soft soil near a railway track were carried out and will be used to validate the numerical implementation. The numerical and experimental results constitute a significant body of useful data to, on the one hand, characterize the response of the environment of tracks and, on the other hand, appreciate the importance of the speed and weight on the behaviour of the structure.

  18. Fourth-Order Vibrational Transition State Theory and Chemical Kinetics

    NASA Astrophysics Data System (ADS)

    Stanton, John F.; Matthews, Devin A.; Gong, Justin Z.

    2015-06-01

    Second-order vibrational perturbation theory (VPT2) is an enormously successful and well-established theory for treating anharmonic effects on the vibrational levels of semi-rigid molecules. Partially as a consequence of the fact that the theory is exact for the Morse potential (which provides an appropriate qualitative model for stretching anharmonicity), VPT2 calculations for such systems with appropriate ab initio potential functions tend to give fundamental and overtone levels that fall within a handful of wavenumbers of experimentally measured positions. As a consequence, the next non-vanishing level of perturbation theory -- VPT4 -- offers only slight improvements over VPT2 and is not practical for most calculations since it requires information about force constants up through sextic. However, VPT4 (as well as VPT2) can be used for other applications such as the next vibrational correction to rotational constants (the ``gammas'') and other spectroscopic parameters. In addition, the marriage of VPT with the semi-classical transition state theory of Miller (SCTST) has recently proven to be a powerful and accurate treatment for chemical kinetics. In this talk, VPT4-based SCTST tunneling probabilities and cumulative reaction probabilities are give for the first time for selected low-dimensional model systems. The prospects for VPT4, both practical and intrinsic, will also be discussed.

  19. Vibrations Generated by Several Nickel-titanium Endodontic File Systems during Canal Shaping in an Ex Vivo Model.

    PubMed

    Choi, Dong-Min; Kim, Jin-Woo; Park, Se-Hee; Cho, Kyung-Mo; Kwak, Sang Won; Kim, Hyeon-Cheol

    2017-07-01

    This study aimed to compare the vibration generated by several nickel-titanium (NiTi) file systems and transmitted to teeth under 2 different motions (continuous rotation motion and reciprocating motion). Sixty J-shaped resin blocks (Endo Training Bloc-J; Dentsply Maillefer, Ballaigues, Switzerland) were trimmed to a root-shaped form and divided into 2 groups according to the types of electric motors: WaveOne motor (WOM, Dentsply Maillefer) and X-Smart Plus motor (XSM, Dentsply Maillefer). Each group was further subdivided into 3 subgroups (n = 10 each) according to the designated file systems: ProTaper Next (PTN, Dentsply Maillefer), ProTaper Universal (PTU, Dentsply Maillefer), and WaveOne (WOP, Dentsply Maillefer) systems. Vibration was measured during the pecking motion using an accelerometer attached to a predetermined consistent position. The average vibration values were subjected to 2-way analysis of variance as well as the t test and Duncan test for post hoc comparison at the 95% confidence interval. Both motor types and instrument types produced significantly different ranges of average vibrations. Regardless of the instrument types, the WOM group generated greater vibration than the XSM group (P < .05). Although PTN and PTU did not show significant differences, the WOP group showed significantly greater vibration than the other groups regardless of motor types (P < .05). Under the limitations of this study design, the reciprocating NiTi file system may generate greater vibration than the continuous rotation NiTi file systems. The motor type also has a significant effect to amplify the vibrations. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Ultra-low-vibration pulse-tube cryocooler system - cooling capacity and vibration

    NASA Astrophysics Data System (ADS)

    Ikushima, Yuki; Li, Rui; Tomaru, Takayuki; Sato, Nobuaki; Suzuki, Toshikazu; Haruyama, Tomiyoshi; Shintomi, Takakazu; Yamamoto, Akira

    2008-09-01

    This report describes the development of low-vibration cooling systems with pulse-tube (PT) cryocoolers. Generally, PT cryocoolers have the advantage of lower vibrations in comparison to those of GM cryocoolers. However, cooling systems for the cryogenic laser interferometer observatory (CLIO), which is a gravitational wave detector, require an operational vibration that is sufficiently lower than that of a commercial PT cryocooler. The required specification for the vibration amplitude in cold stages is less than ±1 μm. Therefore, during the development of low-vibration cooling systems for the CLIO, we introduced advanced countermeasures for commercial PT cryocoolers. The cooling performance and the vibration amplitude were evaluated. The results revealed that 4 K and 80 K PT cooling systems with a vibration amplitude of less than ±1 μm and cooling performance of 4.5 K and 70 K at heat loads of 0.5 W and 50 W, respectively, were developed successfully.

  1. Transmission of vibration across honeycombs and its detection by bee leg receptors

    PubMed

    Sandeman; Tautz; Lindauer

    1996-01-01

    Vibration of the rims of open cells in a honeycomb, applied in the plane of the comb face, is transmitted across the comb. Attenuation or amplification of the vibratory signal depends on its frequency and on the type of comb. In general, framed combs, both large and small, strongly attenuate higher frequencies, whereas these are amplified in small open combs. The very poor transmission properties of the large framed combs used in commercial hives may explain the bees' habit of freeing an area of comb from the frame in those areas used for dancing. Extracellular electrical recordings from the leg of a honeybee detect large action potentials from receptors that monitor extension of the tibia on the femur. Measurements of threshold displacement amplitudes show these receptors to be sensitive to low frequencies. The amplification properties of unframed combs extend the range of these receptor systems to include frequencies that are emitted by the bee during its dance, namely the 15 Hz abdomen waggle and 250 Hz thorax vibration.

  2. Analysis of the tennis racket vibrations during forehand drives: Selection of the mother wavelet.

    PubMed

    Blache, Y; Hautier, C; Lefebvre, F; Djordjevic, A; Creveaux, T; Rogowski, I

    2017-08-16

    The time-frequency analysis of the tennis racket and hand vibrations is of great interest for discomfort and pathology prevention. This study aimed to (i) to assess the stationarity of the vibratory signal of the racket and hand and (ii) to identify the best mother wavelet to perform future time-frequency analysis, (iii) to determine if the stroke spin, racket characteristics and impact zone can influence the selection of the best mother wavelet. A total of 2364 topspin and flat forehand drives were performed by fourteen male competitive tennis players with six different rackets. One tri-axial and one mono-axial accelerometer were taped on the racket throat and dominant hand respectively. The signal stationarity was tested through the wavelet spectrum test. Eighty-nine mother wavelet were tested to select the best mother wavelet based on continuous and discrete transforms. On average only 25±17%, 2±5%, 5±7% and 27±27% of the signal tested respected the hypothesis of stationarity for the three axes of the racket and the hand respectively. Regarding the two methods for the detection of the best mother wavelet, the Daubechy 45 wavelet presented the highest average ranking. No effect of the stroke spin, racket characteristics and impact zone was observed for the selection of the best mother wavelet. It was concluded that alternative approach to Fast Fourier Transform should be used to interpret tennis vibration signals. In the case where wavelet transform is chosen, the Daubechy 45 mother wavelet appeared to be the most suitable. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Vibration sensors

    NASA Astrophysics Data System (ADS)

    Gupta, Amita; Singh, Ranvir; Ahmad, Amir; Kumar, Mahesh

    2003-10-01

    Today, vibration sensors with low and medium sensitivities are in great demand. Their applications include robotics, navigation, machine vibration monitoring, isolation of precision equipment & activation of safety systems e.g. airbags in automobiles. Vibration sensors have been developed at SSPL, using silicon micromachining to sense vibrations in a system in the 30 - 200 Hz frequency band. The sensing element in the silicon vibration sensor is a seismic mass suspended by thin silicon hinges mounted on a metallized glass plate forming a parallel plate capacitor. The movement of the seismic mass along the vertical axis is monitored to sense vibrations. This is obtained by measuring the change in capacitance. The movable plate of the parallel plate capacitor is formed by a block connected to a surrounding frame by four cantilever beams located on sides or corners of the seismic mass. This element is fabricated by silicon micromachining. Several sensors in the chip sizes 1.6 cm x 1.6 cm, 1 cm x 1 cm and 0.7 cm x 0.7 cm have been fabricated. Work done on these sensors, techniques used in processing and silicon to glass bonding are presented in the paper. Performance evaluation of these sensors is also discussed.

  4. Development of an integrated digital hand grip dynamometer and norm of hand grip strength.

    PubMed

    Chang, Ho; Chen, Chih-Hao; Huang, Tung-Sun; Tai, Chun-Yen

    2015-01-01

    This study designs and fabricates a novel integrated digital hand grip dynamometer and analyzes collected grip strength data. The dynamometer directly stores collected data in a computer, unlike those on the market that cannot directly store information. A strain gauge load cell is used as a force sensor. The dynamometer is designed to maximize ergonomics. Excitation voltage of the load cell is 5 V, and a 9 V battery supplies power to its circuit. The signal receiver is National Instruments (NI) data acquisition (DAQ) card that transmits signals to the computer. The operation system is designed using LabView. This study assesses the correlation between variables of collected data. The correlation coefficients for height, weight and palm length were 0.793, 0.609 and 0.715, respectively, indicating that variables were moderately to strongly correlate with grip strength.

  5. Vibration ride comfort criteria

    NASA Technical Reports Server (NTRS)

    Dempsey, T. K.; Leatherwood, J. D.

    1976-01-01

    Results are presented for an experimental study directed to derive equal vibration discomfort curves, to determine the influence of vibration masking in order to account for the total discomfort of any random vibration, and to develop a scale of total vibration discomfort in the case of human response to whole-body vertical vibration. Discomfort is referred to as a subjective discomfort associated with the acceleration level of a particular frequency band. It is shown that passenger discomfort to whole-body vibration increases linearly with acceleration level for each frequency. Empirical data provide a mechanism for determining the degree of masking (or summation) of the discomfort of multiple frequency vibration. A scale for the prediction of passenger discomfort is developed.

  6. Random Vibrations

    NASA Technical Reports Server (NTRS)

    Messaro. Semma; Harrison, Phillip

    2010-01-01

    Ares I Zonal Random vibration environments due to acoustic impingement and combustion processes are develop for liftoff, ascent and reentry. Random Vibration test criteria for Ares I Upper Stage pyrotechnic components are developed by enveloping the applicable zonal environments where each component is located. Random vibration tests will be conducted to assure that these components will survive and function appropriately after exposure to the expected vibration environments. Methodology: Random Vibration test criteria for Ares I Upper Stage pyrotechnic components were desired that would envelope all the applicable environments where each component was located. Applicable Ares I Vehicle drawings and design information needed to be assessed to determine the location(s) for each component on the Ares I Upper Stage. Design and test criteria needed to be developed by plotting and enveloping the applicable environments using Microsoft Excel Spreadsheet Software and documenting them in a report Using Microsoft Word Processing Software. Conclusion: Random vibration liftoff, ascent, and green run design & test criteria for the Upper Stage Pyrotechnic Components were developed by using Microsoft Excel to envelope zonal environments applicable to each component. Results were transferred from Excel into a report using Microsoft Word. After the report is reviewed and edited by my mentor it will be submitted for publication as an attachment to a memorandum. Pyrotechnic component designers will extract criteria from my report for incorporation into the design and test specifications for components. Eventually the hardware will be tested to the environments I developed to assure that the components will survive and function appropriately after exposure to the expected vibration environments.

  7. Simulation of Satellite Vibration Test

    NASA Astrophysics Data System (ADS)

    Bettacchioli, Alain

    2014-06-01

    During every mechanical qualification test of satellites on vibrator, we systematically notice beating phenomena that appear every time we cross a mode's frequency. There could lead to an over-qualification of the tested specimen when the beating reaches a maximum and a under-qualification when the beating passes by a minimum. On a satellite, three lateral modes raise such a problem in a recurring way: the first structure mode (between 10 and 15 hertz) and the two tanks modes (between 35 and 50 hertz).To step forward in the resolution of this problem, we are developing a simulator which is based on the identification of the responses of the accelerometers that are fixed on the satellite and on the shaker slip table. The estimated transfer functions then allow to reconstruct at once the sensors response and the drive which generated them.For the simulation, we do not select all the sensors but only those on the slip table and those used to limit the input level (notching). We may also add those which were close to generate a notching.To perform its calculations, the simulator reproduces on one hand the unity amplitude signal (cola) which serves as frequency reference for the sweep achievement (generally 3 octaves per minute from 5 to 100 and even 150 Hertz), and on the other hand, the vibrator control loop. The drive amplitude is calculated at each cola's period by taking into account a compression factor. The control applied through the amplifier to the shaker coil is the product of this amplitude by the cola. The simulated measurements are updated at each sampling period thanks to the propagation of the identified model. The superposition of these curves on those supplied by real sensors during the tests allows to validate the simulation.Thereby, it seems possible to actively control the beatings thanks to a real-time corrector which uses these identifications.

  8. PREFACE: Vibrations at surfaces Vibrations at surfaces

    NASA Astrophysics Data System (ADS)

    Rahman, Talat S.

    2011-12-01

    This special issue is dedicated to the phenomenon of vibrations at surfaces—a topic that was indispensible a couple of decades ago, since it was one of the few phenomena capable of revealing the nature of binding at solid surfaces. For clean surfaces, the frequencies of modes with characteristic displacement patterns revealed how surface geometry, as well as the nature of binding between atoms in the surface layers, could be different from that in the bulk solid. Dispersion of the surface phonons provided further measures of interatomic interactions. For chemisorbed molecules on surfaces, frequencies and dispersion of the vibrational modes were also critical for determining adsorption sites. In other words, vibrations at surfaces served as a reliable means of extracting information about surface structure, chemisorption and overlayer formation. Experimental techniques, such as electron energy loss spectroscopy and helium-atom-surface scattering, coupled with infra-red spectroscopy, were continually refined and their resolutions enhanced to capture subtleties in the dynamics of atoms and molecules at surfaces. Theoretical methods, whether based on empirical and semi-empirical interatomic potential or on ab initio electronic structure calculations, helped decipher experimental observations and provide deeper insights into the nature of the bond between atoms and molecules in regions of reduced symmetry, as encountered on solid surfaces. Vibrations at surfaces were thus an integral part of the set of phenomena that characterized surface science. Dedicated workshops and conferences were held to explore the variety of interesting and puzzling features revealed in experimental and theoretical investigations of surface vibrational modes and their dispersion. One such conference, Vibrations at Surfaces, first organized by Harald Ibach in Juelich in 1980, continues to this day. The 13th International Conference on Vibrations at Surfaces was held at the University of

  9. Vibration amplitude sonoelastography lesion imaging using low-frequency audible vibration

    NASA Astrophysics Data System (ADS)

    Taylor, Lawrence; Parker, Kevin

    2003-04-01

    Sonoelastography or vibration amplitude imaging is an ultrasound imaging technique in which low-amplitude, low-frequency shear waves, less than 0.1-mm displacement and 1-kHz frequency, are propagated deep into tissue, while real time Doppler techniques are used to image the resulting vibration pattern. Finite-element studies and experiments on tissue-mimicking phantoms verify that a discrete hard inhomogeneity present within a larger region of soft tissue will cause a decrease in the vibration field at its location. This forms the basis for tumor detection using sonoelastography. Real time relative imaging of the vibration field is possible because a vibrating particle will phase modulate an ultrasound signal. The particle's amplitude is directly proportional to the spectral spread of the reflected Doppler echo. Real time estimation of the variance of the Doppler power spectrum at each pixel allows the vibration field to be imaged. Results are shown for phantom lesions, thermal lesions, and 3-D in vitro and 2-D in vivo prostate cancer. MRI and whole mount histology is used to validate the system accuracy.

  10. Reducing variable frequency vibrations in a powertrain system with an adaptive tuned vibration absorber group

    NASA Astrophysics Data System (ADS)

    Gao, Pu; Xiang, Changle; Liu, Hui; Zhou, Han

    2018-07-01

    Based on a multiple degrees of freedom dynamic model of a vehicle powertrain system, natural vibration analyses and sensitivity analyses of the eigenvalues are performed to determine the key inertia for each natural vibration of a powertrain system. Then, the results are used to optimize the installation position of each adaptive tuned vibration absorber. According to the relationship between the variable frequency torque excitation and the natural vibration of a powertrain system, the entire vibration frequency band is divided into segments, and the auxiliary vibration absorber and dominant vibration absorber are determined for each sensitive frequency band. The optimum parameters of the auxiliary vibration absorber are calculated based on the optimal frequency ratio and the optimal damping ratio of the passive vibration absorber. The instantaneous change state of the natural vibrations of a powertrain system with adaptive tuned vibration absorbers is studied, and the optimized start and stop tuning frequencies of the adaptive tuned vibration absorber are obtained. These frequencies can be translated into the optimum parameters of the dominant vibration absorber. Finally, the optimal tuning scheme for the adaptive tuned vibration absorber group, which can be used to reduce the variable frequency vibrations of a powertrain system, is proposed, and corresponding numerical simulations are performed. The simulation time history signals are transformed into three-dimensional information related to time, frequency and vibration energy via the Hilbert-Huang transform (HHT). A comprehensive time-frequency analysis is then conducted to verify that the optimal tuning scheme for the adaptive tuned vibration absorber group can significantly reduce the variable frequency vibrations of a powertrain system.

  11. Virtual hand: a 3D tactile interface to virtual environments

    NASA Astrophysics Data System (ADS)

    Rogowitz, Bernice E.; Borrel, Paul

    2008-02-01

    We introduce a novel system that allows users to experience the sensation of touch in a computer graphics environment. In this system, the user places his/her hand on an array of pins, which is moved about space on a 6 degree-of-freedom robot arm. The surface of the pins defines a surface in the virtual world. This "virtual hand" can move about the virtual world. When the virtual hand encounters an object in the virtual world, the heights of the pins are adjusted so that they represent the object's shape, surface, and texture. A control system integrates pin and robot arm motions to transmit information about objects in the computer graphics world to the user. It also allows the user to edit, change and move the virtual objects, shapes and textures. This system provides a general framework for touching, manipulating, and modifying objects in a 3-D computer graphics environment, which may be useful in a wide range of applications, including computer games, computer aided design systems, and immersive virtual worlds.

  12. Exploring long-wave infrared transmitting materials with AxBy form: First-principles gene-like studies.

    PubMed

    Du, Jia-Ren; Chen, Nian-Ke; Li, Xian-Bin; Xie, Sheng-Yi; Tian, Wei Quan; Wang, Xian-Yin; Tu, Hai-Ling; Sun, Hong-Bo

    2016-02-23

    Long-wave infrared (8-12 μm) transmitting materials play critical roles in space science and electronic science. However, the paradox between their mechanical strength and infrared transmitting performance seriously prohibits their applications in harsh external environment. From the experimental view, searching a good window material compatible with both properties is a vast trail-and-error engineering project, which is not readily achieved efficiently. In this work, we propose a very simple and efficient method to explore potential infrared window materials with suitable mechanical property by first-principles gene-like searching. Two hundred and fifty-three potential materials are evaluated to find their bulk modulus (for mechanical performance) and phonon vibrational frequency (for optical performance). Seven new potential candidates are selected, namely TiSe, TiS, MgS, CdF2, HgF2, CdO, and SrO. Especially, the performances of TiS and CdF2 can be comparable to that of the most popular commercial ZnS at high temperature. Finally, we propose possible ranges of infrared transmission for halogen, chalcogen and nitrogen compounds respectively to guide further exploration. The present strategy to explore IR window materials can significantly speed up the new development progress. The same idea can be used for other material rapid searching towards special functions and applications.

  13. Effects of vibration on spasticity in individuals with spinal cord injury: a scoping systematic review.

    PubMed

    Sadeghi, Mahsa; Sawatzky, Bonita

    2014-11-01

    The objective of this systematic review was to evaluate how whole-body vibration (WBV) or focal vibration (FV) would change spasticity in individuals with spinal cord injury (SCI). A search was conducted of MEDLINE, EMBASE, CINAHL, and PsycINFO electronic databases. A hand search was conducted of the bibliographies of articles and journals relevant to the research question. The inclusion criteria were three or more individuals, 17 yrs or older, with SCI who experience spasticity, and WBV or FV application. The evidence level of all ten identified studies (195 SCI subjects) was low on the basis of Centre for Evidence Based Medicine level of evidence. WBV (n = 1) and FV (n = 9) were applied to assess the effects of vibration on different measures of spasticity in individuals with SCI. FV application resulted in a short-term spasticity reduction lasting for a maximum of 24 hrs. Neurophysiologic measures showed H-reflex inhibition in individuals with SCI after FV application. WBV resulted in a decrease in spasticity lasting for 6-8 days after the last vibration session. WBV and FV might decrease spasticity for a short period, but no evidence-based recommendation can be drawn from the literature to guide rehabilitation medicine clinicians to manage spasticity with vibration application.

  14. A remote monitor of bed patient cardiac vibration, respiration and movement.

    PubMed

    Mukai, Koji; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Maki, Hiromichi; Caldwell, W Morton

    2009-01-01

    We have developed a remote system for monitoring heart rate, respiration rate and movement behavior of at-home elderly people who are living alone. The system consists of a 40 kHz ultrasonic transmitter and receiver, linear integrated circuits, a low-power 8-bit single chip microcomputer and an Internet server computer. The 40 kHz ultrasonic transmitter and receiver are installed into a bed mattress. The transmitted signal diffuses into the bed mattress, and the amplitude of the received ultrasonic wave is modulated by the shape of the mattress and parameters such as respiration, cardiac vibration and movement. The modulated ultrasonic signal is received and demodulated by an envelope detection circuit. Low, high and band pass filters separate the respiration, cardiac vibration and movement signals, which are fed into the microcontroller and digitized at a sampling rate of 50 Hz by 8-bit A/D converters. The digitized data are sent to the server computer as a serial signal. This computer stores the data and also creates a graphic chart of the latest hour. The person's family or caregiver can download this chart via the Internet at any time.

  15. Short-Term Effects of Whole-Body Vibration Combined with Task-Related Training on Upper Extremity Function, Spasticity, and Grip Strength in Subjects with Poststroke Hemiplegia: A Pilot Randomized Controlled Trial.

    PubMed

    Lee, Jung-Sun; Kim, Chang-Yong; Kim, Hyeong-Dong

    2016-08-01

    The aim of this study was to determine the effect of whole-body vibration training combined with task-related training on arm function, spasticity, and grip strength in subjects with poststroke hemiplegia. Forty-five subjects with poststroke were randomly allocated to 3 groups, each with 15 subjects as follows: control group, whole-body vibration group, and whole-body vibration plus task-related training group. Outcome was evaluated by clinical evaluation and measurements of the grip strength before and 4 weeks after intervention. Our results show that there was a significantly greater increase in the Fugl-Meyer scale, maximal grip strength of the affected hand, and grip strength normalized to the less affected hand in subjects undergoing the whole-body vibration training compared with the control group after the test. Furthermore, there was a significantly greater increase in the Wolf motor function test and a decrease in the modified Ashworth spasticity total scores in subjects who underwent whole-body vibration plus task-related training compared with those in the other 2 groups after the test. The findings indicate that the use of whole-body vibration training combined with task-related training has more benefits on the improvement of arm function, spasticity, and maximal grip strength than conventional upper limb training alone or with whole-body vibration in people with poststroke hemiplegia.

  16. Noncontact Electromagnetic Vibration Source

    NASA Technical Reports Server (NTRS)

    Namkung, Min; Fulton, James P.; Wincheski, Buzz A.

    1994-01-01

    Metal aircraft skins scanned rapidly in vibration tests. Relatively simple combination of permanent magnets and electromagnet serves as noncontact vibration source for nondestructive testing of metal aircraft skins. In test, source excites vibrations, and vibration waveforms measured, then analyzed for changes in resonances signifying cracks and other flaws.

  17. Local vibration inhibits H-reflex but does not compromise manual dexterity and does not increase tremor.

    PubMed

    Budini, Francesco; Laudani, Luca; Bernardini, Sergio; Macaluso, Andrea

    2017-10-01

    The present work aimed at investigating the effects of local vibration on upper limb postural and kinetic tremor, on manual dexterity and on spinal reflex excitability. Previous studies have demonstrated a decrease in spinal reflex excitability and in force fluctuations in the lower limb but an increase in force fluctuation in the upper limbs. As hand steadiness is of vital importance in many daily-based tasks, and local vibration may also be applied in movement disorders, we decided to further explore this phenomenon. Ten healthy volunteers (26±3years) were tested for H reflex, postural and kinetic tremor and manual dexterity through a Purdue test. EMG was recorded from flexor carpi radialis (FCR) and extensor digitorum communis (EDC). Measurements were repeated at baseline, after a control period during which no vibration was delivered and after vibration. Intervention consisted in holding for two minutes a vibrating handle (frequency 75Hz, displacement∼7mm), control consisted in holding for two minutes the same handle powered off. Reflex excitability decreased after vibration whilst postural tremor and manual dexterity were not affected. Peak kinetic tremor frequency increased from baseline to control measurements (P=0.002). Co-activation EDC/FCR increased from control to vibration (P=0.021). These results show that two minutes local vibration lead to a decrease in spinal excitability, did not compromise manual dexterity and did not increase tremor; however, in contrast with expectations, tremor did not decrease. It is suggested that vibration activated several mechanisms with opposite effects, which resulted in a neutral outcome on postural and kinetic tremor. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Sexually Transmitted Infections, Pregnancy, and Breastfeeding

    MedlinePlus

    ... email updates Submit Sexually transmitted infections, pregnancy, and breastfeeding Sexually transmitted infections (STIs) are also called sexually ... away. Are STI treatments safe to use while breastfeeding? If you are being treated for an STI, ...

  19. Combined isometric and vibration training does not enhance strength beyond that of isometric training alone.

    PubMed

    Fisher, J; Van-Dongen, M; Sutherland, R

    2014-10-08

    Research considering combined vibration and strength training is extensive yet results are equivocal. However, to date there appears no research which has considered the combination of both direct vibration and whole---body vibration when used in an isometric deadlift position. The aims of this study were to compare groups performing isometric training with and without direct and whole---body vibration. Twenty four participants (19---24 years) were randomly divided into: isometric training with vibration (ST+VT: n=8), isometric training without vibration (ST: n=8), and control (CON: n=8). Within the training groups participants trained twice per week, for 6 weeks, performing 6---sets of maximal isometric deadlift contractions, increasing in duration from 30 seconds to 40 seconds (weeks 1---6). Hip and knee angle was maintained at 60° and 110°, respectively for both testing and training. Training sessions for ST+VT were identical to ST with the addition of a direct vibratory stimulus through hand---held straps and whole---body vibration via standing on vibration a platform. The amplitude remained constant (2mm) throughout the intervention whilst the frequency increased from 35Hz to 50Hz. Pre--- and post---test isometric strength was measured using an isometric deadlift dynamometer. Results revealed significant increases in isometric strength for both ST+VT (p < 0.001, 23.8%) and ST (p < 0.001, 32.5%) compared to CON, with no significant differences between ST+VT and ST training groups. The present study provides evidence to suggest that there are no greater gains to be incurred by the addition of a vibratory stimulus to traditional strength training.

  20. Combined isometric and vibration training does not enhance strength beyond that of isometric training alone.

    PubMed

    Fisher, J; Van-Dongen, M; Sutherland, R

    2015-09-01

    Research considering combined vibration and strength training is extensive yet results are equivocal. However, to date there appears no research which has considered the combination of both direct vibration and whole-body vibration when used in an isometric deadlift position. The aim of this study was to compare groups performing isometric training with and without direct and whole-body vibration. Twenty four participants (19-24 years) were randomly divided into: isometric training with vibration (ST+VT: N.=8), isometric training without vibration (ST: N.=8), and control (CON: N.=8). Within the training groups participants trained twice per week, for 6 weeks, performing 6-sets of maximal isometric deadlift contractions, increasing in duration from 30 seconds to 40 seconds (weeks 1-6). Hip and knee angle was maintained at 60° and 110°, respectively for both testing and training. Training sessions for ST+VT were identical to ST with the addition of a direct vibratory stimulus through hand-held straps and whole-body vibration via standing on vibration a platform. The amplitude remained constant (2 mm) throughout the intervention whilst the frequency increased from 35Hz to 50Hz. Pre- and post-test isometric strength was measured using an isometric deadlift dynamometer. Results revealed significant increases in isometric strength for both ST+VT (P<0.001, 23.8%) and ST (P<0.001, 32.5%) compared to CON, with no significant differences between ST+VT and ST training groups. The present study provides evidence to suggest that there are no greater gains to be incurred by the addition of a vibratory stimulus to traditional strength training.

  1. Epidemiologic survey of vibration syndrome among riveters, chippers and grinders in the railroad system of the People's Republic of China.

    PubMed

    Yu, Z S; Chao, H; Qiao, L; Qian, D S; Ye, Y H

    1986-08-01

    Vibration syndrome caused by hand-held vibrating tools in 14 locomotive and rolling stock plants in four regions of the People's Republic of China (south, north, middlewest, and northeast) and the influence of climatic factors on its prevalence rate were studied. For 1,028 male workers (705 riveters, 284 chippers, and 39 grinders), the prevalence rate of the syndrome was 13.4% and for a reference group of 256 workers it was 1.6%. The prevalence rate of white finger in the four regions differed and was higher in northeast and north China than in south and middlewest China. This finding suggests that cold climate and humidity may be causative factors of the vibration syndrome.

  2. [Voice and vibration sensations in the speech forming organs: clinical and theoretical aspects of rare symptoms specific for schizophrenia].

    PubMed

    Vilela, W; Lolas, F; Wolpert, E

    1978-01-01

    When studying 750 psychiatric in-patients with psychoses of various diagnostic groups, the symptoms of voice sensations and vibration feelings could only be found among patients with paranoid schizophrenia. In addition, these symptoms were located exclusively in body areas that are involved in the peripheral motor production of voice and speech (areas of head, throat, thorax). In 11 of 15 such cases that could be identified, the sensations of voices and vibrations occurred simultaneously and in identical body parts; in the remaining 4 cases only voices without vibration sensations were reported. Therefore these symptoms can be considered as highly specific for schizophrenia. According to the terminology of Bleuler these two symptoms are because of their rareness to be taken as accessoric symptoms; according to the terminology of Kurt Schneider they have the value of first rank symptoms because of their highly diagnostic specifity for schizophrenia. The pathogenesis of these symptoms is on the one hand discussed under the perspective of language development and the changing function of language for behaviour control; on the other hand, the pathogenesis of these symptoms is discussed from the viewpoint of cybernetic, or neurophysiological-neuroanatomical foundation of speech production and speech control. Both models of explanation have in common that the ideational component of speech is noticed as acustic halluzinations and the motor proprioceptive part of speech is noticed as sensation of vibrations, both in a typically schiphrenic manner, i.e. dissociated and ego-alienated.

  3. 47 CFR 95.135 - Maximum authorized transmitting power.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... transmitting power. (a) No station may transmit with more than 50 watts output power. (b) [Reserved] (c) A small control station at a point north of Line A or east of Line C must transmit with no more than 5 watts ERP. (d) A fixed station must transmit with no more than 15 watts output power. (e) A small base...

  4. Talker Localization Based on Interference between Transmitted and Reflected Audible Sound

    NASA Astrophysics Data System (ADS)

    Nakayama, Masato; Nakasako, Noboru; Shinohara, Toshihiro; Uebo, Tetsuji

    In many engineering fields, distance to targets is very important. General distance measurement method uses a time delay between transmitted and reflected waves, but it is difficult to estimate the short distance. On the other hand, the method using phase interference to measure the short distance has been known in the field of microwave radar. Therefore, we have proposed the distance estimation method based on interference between transmitted and reflected audible sound, which can measure the distance between microphone and target with one microphone and one loudspeaker. In this paper, we propose talker localization method based on distance estimation using phase interference. We expand the distance estimation method using phase interference into two microphones (microphone array) in order to estimate talker position. The proposed method can estimate talker position by measuring the distance and direction between target and microphone array. In addition, talker's speech is regarded as a noise in the proposed method. Therefore, we also propose combination of the proposed method and CSP (Cross-power Spectrum Phase analysis) method which is one of the DOA (Direction Of Arrival) estimation methods. We evaluated the performance of talker localization in real environments. The experimental result shows the effectiveness of the proposed method.

  5. Mechanical vibration compensation method for 3D+t multi-particle tracking in microscopic volumes.

    PubMed

    Pimentel, A; Corkidi, G

    2009-01-01

    The acquisition and analysis of data in microscopic systems with spatiotemporal evolution is a very relevant topic. In this work, we describe a method to optimize an experimental setup for acquiring and processing spatiotemporal (3D+t) data in microscopic systems. The method is applied to a three-dimensional multi-tracking and analysis system of free-swimming sperm trajectories previously developed. The experimental set uses a piezoelectric device making oscillate a large focal-distance objective mounted on an inverted microscope (over its optical axis) to acquire stacks of images at a high frame rate over a depth on the order of 250 microns. A problem arise when the piezoelectric device oscillates, in such a way that a vibration is transmitted to the whole microscope, inducing undesirable 3D vibrations to the whole set. For this reason, as a first step, the biological preparation was isolated from the body of the microscope to avoid modifying the free swimming pattern of the microorganism due to the transmission of these vibrations. Nevertheless, as the image capturing device is mechanically attached to the "vibrating" microscope, the resulting acquired data are contaminated with an undesirable 3D movement that biases the original trajectory of these high speed moving cells. The proposed optimization method determines the functional form of these 3D oscillations to neutralize them from the original acquired data set. Given the spatial scale of the system, the added correction increases significantly the data accuracy. The optimized system may be very useful in a wide variety of 3D+t applications using moving optical devices.

  6. Vibration dampener for dampening vibration of a tubular member

    DOEpatents

    Obermeyer, F.D.; Middlebrooks, W.B.; DeMario, E.E.

    1994-10-18

    Vibration dampener for dampening vibration of a tubular member, such as an instrumentation tube of the type found in nuclear reactor pressure vessels is disclosed. The instrumentation tube is received in an outer tubular member, such as a guide thimble tube. The vibration dampener comprises an annular sleeve which is attachable to the inside surface of the guide thimble tube and which is sized to surround the instrumentation tube. Dimples are attached to the interior wall of the sleeve for radially supporting the instrumentation tube. The wall of the sleeve has a flexible spring member, which is formed from the wall, disposed opposite the dimples for biasing the instrumentation tube into abutment with the dimples. Flow-induced vibration of the instrumentation tube will cause it to move out of contact with the dimples and further engage the spring member, which will flex a predetermined amount and exert a reactive force against the instrumentation tube to restrain its movement. The amount by which the spring member will flex is less than the unrestrained amplitude of vibration of the instrumentation tube. The reactive force exerted against the instrumentation tube will be sufficient to return it to its original axial position within the thimble tube. In this manner, vibration of the instrumentation tube is dampened so that in-core physics measurements are accurate and so that the instrumentation tube will not wear against the inside surface of the guide thimble tube. 14 figs.

  7. Vibration dampener for dampening vibration of a tubular member

    DOEpatents

    Obermeyer, Franklin D.; Middlebrooks, Willis B.; DeMario, Edmund E.

    1994-01-01

    Vibration dampener for dampening vibration of a tubular member, such as an instrumentation tube of the type found in nuclear reactor pressure vessels. The instrumentation tube is received in an outer tubular member, such as a guide thimble tube. The vibration dampener comprises an annular sleeve which is attachable to the inside surface of the guide thimble tube and which is sized to surround the instrumentation tube. Dimples are attached to the interior wall of the sleeve for radially supporting the instrumentation tube. The wall of the sleeve has a flexible spring member, which is formed from the wall, disposed opposite the dimples for biasing the instrumentation tube into abutment with the dimples. Flow-induced vibration of the instrumentation tube will cause it to move out of contact with the dimples and further engage the spring member, which will flex a predetermined amount and exert a reactive force against the instrumentation tube to restrain its movement. The amount by which the spring member will flex is less than the unrestrained amplitude of vibration of the instrumentation tube. The reactive force exerted against the instrumentation tube will be sufficient to return it to its original axial position within the thimble tube. In this manner, vibration of the instrumentation tube is dampened so that in-core physics measurements are accurate and so that the instrumentation tube will not wear against the inside surface of the guide thimble tube.

  8. Vibration mode and vibration shape under excitation of a three phase model transformer core

    NASA Astrophysics Data System (ADS)

    Okabe, Seiji; Ishigaki, Yusuke; Omura, Takeshi

    2018-04-01

    Structural vibration characteristics and vibration shapes under three-phase excitation of a archetype transformer core were investigated to consider their influences on transformer noise. Acoustic noise and vibration behavior were measured in a three-limb model transformer core. Experimental modal analysis by impact test was performed. The vibration shapes were measured by a laser scanning vibrometer at different exciting frequencies. Vibration amplitude of the core in out-of-plane direction were relatively larger than those in other two in-plane directions. It was consistent with the result that the frequency response function of the core in out-of-plane direction was larger by about 20 dB or more than those in in-plane directions. There were many vibration modes having bending deformation of limbs in out-of-plane direction. The vibration shapes of the core when excited at 50 Hz and 60 Hz were almost the same because the fundamental frequencies of the vibration were not close to the resonance frequencies. When excitation frequency was 69 Hz which was half of one of the resonance frequencies, the vibration shape changed to the one similar to the resonance vibration mode. Existence of many vibration modes in out-of-plane direction of the core was presumed to be a reason why frequency characteristics of magnetostriction and transformer noise do not coincide.

  9. Systematic analyses of vibration noise of a vibration isolation system for high-resolution scanning tunneling microscopes.

    PubMed

    Iwaya, Katsuya; Shimizu, Ryota; Hashizume, Tomihiro; Hitosugi, Taro

    2011-08-01

    We designed and constructed an effective vibration isolation system for stable scanning tunneling microscopy measurements using a separate foundation and two vibration isolation stages (i.e., a combination of passive and active vibration isolation dampers). Systematic analyses of vibration data along the horizontal and vertical directions are present, including the vibration transfer functions of each stage and the overall vibration isolation system. To demonstrate the performance of the system, tunneling current noise measurements are conducted with and without the vibration isolation. Combining passive and active vibration isolation dampers successfully removes most of the vibration noise in the tunneling current up to 100 Hz. These comprehensive vibration noise data, along with details of the entire system, can be used to establish a clear guideline for building an effective vibration isolation system for various scanning probe microscopes and electron microscopes.

  10. Vibration Analysis of Beam and Block Precast Slab System due to Human Vibrations

    NASA Astrophysics Data System (ADS)

    Chik, T. N. T.; Kamil, M. R. H.; Yusoff, N. A.

    2018-04-01

    Beam and block precast slabs system are very efficient which generally give maximum structural performance where their voids based on the design of the unit soffit block allow a significant reduction of the whole slab self-weight. Initially for some combinations of components or the joint connection of the structural slab, this structural system may be susceptible to excessive vibrations that could effects the performance and also serviceability. Dynamic forces are excited from people walking and jumping which produced vibrations to the slab system in the buildings. Few studies concluded that human induced vibration on precast slabs system may be harmful to structural performance and mitigate the human comfort level. This study will investigate the vibration analysis of beam and block precast slab by using finite element method at the school building. Human activities which are excited from jumping and walking will induce the vibrations signal to the building. Laser Doppler Vibrometer (LDV) was used to measure the dynamic responses of slab towards the vibration sources. Five different points were assigned specifically where each of location will determine the behaviour of the entire slabs. The finite element analyses were developed in ABAQUS software and the data was further processed in MATLAB ModalV to assess the vibration criteria. The results indicated that the beam and block precast systems adequate enough to the vibration serviceability and human comfort criteria. The overall vibration level obtained was fell under VC-E curve which it is generally under the maximum permissible level of vibrations. The vibration level on the slab is acceptable within the limit that have been used by Gordon.

  11. Analysis of Hand and Wrist Postural Synergies in Tolerance Grasping of Various Objects

    PubMed Central

    Liu, Yuan; Jiang, Li; Yang, Dapeng; Liu, Hong

    2016-01-01

    Human can successfully grasp various objects in different acceptable relative positions between human hand and objects. This grasp functionality can be described as the grasp tolerance of human hand, which is a significant functionality of human grasp. To understand the motor control of human hand completely, an analysis of hand and wrist postural synergies in tolerance grasping of various objects is needed. Ten healthy right-handed subjects were asked to perform the tolerance grasping with right hand using 6 objects of different shapes, sizes and relative positions between human hand and objects. Subjects were wearing CyberGlove attaching motion tracker on right hand, allowing a measurement of the hand and wrist postures. Correlation analysis of joints and inter-joint/inter-finger modules were carried on to explore the coordination between joints or modules. As the correlation between hand and wrist module is not obvious in tolerance grasping, individual analysis of wrist synergies would be more practical. In this case, postural synergies of hand and wrist were then presented separately through principal component analysis (PCA), expressed through the principal component (PC) information transmitted ratio, PC elements distribution and reconstructed angle error of joints. Results on correlation comparison of different module movements can be well explained by the influence factors of the joint movement correlation. Moreover, correlation analysis of joints and modules showed the wrist module had the lowest correlation among all inter-finger and inter-joint modules. Hand and wrist postures were both sufficient to be described by a few principal components. In terms of the PC elements distribution of hand postures, compared with previous investigations, there was a greater proportion of movement in the thumb joints especially the interphalangeal (IP) and opposition rotation (ROT) joint. The research could serve to a complete understanding of hand grasp, and the design

  12. Amplified Pilot Head Vibration and the Effects of Vibration Mitigation on Neck Muscle Strain.

    PubMed

    Wright Beatty, Heather E; Law, Andrew J; Thomas, J Russell; Wickramasinghe, Viresh

    2018-06-01

    Rotary wing pilot neck strain is increasing in prevalence due to the combined effects of head supported mass (e.g., Night Vision Goggles, head mounted displays) and whole-body vibration. This study examined the physiological responses of pilots during exposure to whole-body vibration (WBV) representative of the National Research Council's Bell 412 helicopter in forward flight. WBV levels were measured and evaluated using the ISO-2631-1-1997 WBV standards. Twelve pilots (aged 20-59 yr, 7 of the 12 with 20+ years flight experience) underwent six 15-min vibration trials on a human rated shaker platform. Participants were exposed to three vibration levels (-25%, normal, and +25% amplitude; Levels 1-3, respectively) while seated on an Original Equipment Manufacturer (OEM) or vibration mitigating (MIT) cushion. Upper back and neck electromyography (EMG) and acceleration were continuously recorded. Normalized EMG amplitude was higher using the OEM compared to the MIT during Level 2 (0.18 vs. -0.27) and Level 3 (0.24 vs. -0.14) for the anterior neck muscles. Health weighted vibration amplitude at the head (Mean of 3 levels: OEM = 1.19 and MIT = 1.11 m · s-2) was larger than the vibration amplitude at the seat (Mean of 3 levels: OEM = 0.77 and MIT = 0.70 m · s-2). The amplification of head vibration relative to the seat, and the significant effects of vibration level, as well as the vibration mitigation cushion, on neck EMG amplitude support the need for revisions to the ISO-2631-1 standard to account for the head and neck response to whole-body vibration.Wright Beatty HE, Law AJ, Thomas JR, Wickramasinghe V. Amplified pilot head vibration and the effects of vibration mitigation on neck muscle strain. Aerosp Med Hum Perform. 2018; 89(6):510-519.

  13. Effect of vibration duration on human discomfort. [passenger comfort and random vibration

    NASA Technical Reports Server (NTRS)

    Clevenson, S. A.; Dempsey, T. K.; Leatherwood, J. D.

    1978-01-01

    The duration effects of random vertical vibration on passenger discomfort were studied in a simulated section of an aircraft cabin configured to seat six persons in tourist-class style. Variables of the study included time of exposure (0.25 min to 60 min) and the rms amplitude of vibration (0.025g to 0.100g). The vibrations had a white noise spectrum with a bandwidth of 10 Hz centered at 5 Hz. Data indicate that the discomfort threshold occurred at an rms vertical acceleration level of 0.027g for all durations of vibration. However, for acceleration levels that exceeded the discomfort threshold, a systematic decrease in discomfort occurred as a function of increasing duration of vibration. For the range of accelerations used, the magnitude of the discomfort decrement was shown to be independent of acceleration level. The results suggest that discomfort from vertical vibration applied in the frequency range at which humans are most sensitive decreases with longer exposure, which is the opposite of the recommendation of the International Standard ISO 2631-1974 (E) Guide for the Evaluation of Human Exposure to Whole-Body Vibration.

  14. Effects of interset whole-body vibration on bench press resistance training in trained and untrained individuals.

    PubMed

    Timon, Rafael; Collado-Mateo, Daniel; Olcina, Guillermo; Gusi, Narcis

    2016-03-01

    Previous studies have demonstrated positive effects of acute vibration exercise on concentric strength and power, but few have observed the effects of vibration exposure on resistance training. The aim of this study was to verify the effects of whole body vibration applied to the chest via hands on bench press resistance training in trained and untrained individuals. Nineteen participants (10 recreationally trained bodybuilders and 9 untrained students) performed two randomized sessions of resistance training on separate days. Each strength session consisted of 3 bench press sets with a load of 75% 1RM to failure in each set, with 2 minutes' rest between sets. All subjects performed the same strength training with either, vibration exposure (12 Hz, 4 mm) of 30 seconds immediately before each bench press set or without vibration. Number of total repetitions, kinematic parameters, blood lactate and perceived exertion were analyzed. In the untrained group, vibration exposure caused a significant increase in the mean velocity (from 0.36±0.02 to 0.39±0.03 m/s) and acceleration (from 0.75±0.10 to 0.86±0.09 m/s2), as well as a decrease in perceived effort (from 8±0.57 to 7.35±0.47) in the first bench press set, but no change was observed in the third bench press set. In the recreationally trained bodybuilders, vibration exposure did not cause any improvement on the performance of bench press resistance training. These results suggest that vibration exposure applied just before the bench press exercise could be a good practice to be implemented by untrained individuals in resistance training.

  15. Extracellular signal-regulated kinase activation and endothelin-1 production in human endothelial cells exposed to vibration

    PubMed Central

    White, Charles R; Haidekker, Mark A; Stevens, Hazel Y; Frangos, John A

    2004-01-01

    Hand–arm vibration syndrome is a vascular disease of occupational origin and a form of secondary Raynaud's phenomenon. Chronic exposure to hand-held vibrating tools may cause endothelial injury. This study investigates the biomechanical forces involved in the transduction of fluid vibration in the endothelium. Human endothelial cells were exposed to direct vibration and rapid low-volume fluid oscillation. Rapid low-volume fluid oscillation was used to simulate the effects of vibration by generating defined temporal gradients in fluid shear stress across an endothelial monolayer. Extracellular signal-regulated kinase (ERK1/2) phosphorylation and endothelin-1 (ET-1) release were monitored as specific biochemical markers for temporal gradients and endothelial response, respectively. Both vibrational methods were found to phosphorylate ERK1/2 in a similar pattern. At a fixed frequency of fluid oscillation where the duration of each pulse cycle remained constant, ERK1/2 phosphorylation increased with the increasing magnitude of the applied temporal gradient. However, when the frequency of flow oscillation was increased (thus decreasing the duration of each pulse cycle), ERK1/2 phosphorylation was attenuated across all temporal gradient flow profiles. Fluid oscillation significantly stimulated ET-1 release compared to steady flow, and endothelin-1 was also attenuated with the increase in oscillation frequency. Taken together, these results show that both the absolute magnitude of the temporal gradient and the frequency/duration of each pulse cycle play a role in the biomechanical transduction of fluid vibrational forces in endothelial cells. Furthermore, this study reports for the first time a link between the ERK1/2 signal transduction pathway and transmission of vibrational forces in the endothelium. PMID:14724194

  16. Control of liquid crystal molecular orientation using ultrasound vibration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taniguchi, Satoki; Wave Electronics Research Center, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe, Kyoto 610-0321; Koyama, Daisuke

    2016-03-07

    We propose a technique to control the orientation of nematic liquid crystals using ultrasound and investigate the optical characteristics of the oriented samples. An ultrasonic liquid crystal cell with a thickness of 5–25 μm and two ultrasonic lead zirconate titanate transducers was fabricated. By exciting the ultrasonic transducers, the flexural vibration modes were generated on the cell. An acoustic radiation force to the liquid crystal layer was generated, changing the molecular orientation and thus the light transmission. By modulating the ultrasonic driving frequency and voltage, the spatial distribution of the molecular orientation of the liquid crystals could be controlled. The distributionmore » of the transmitted light intensity depends on the thickness of the liquid crystal layer because the acoustic field in the liquid crystal layer is changed by the orientational film.« less

  17. Sexually transmitted diseases in Indonesia.

    PubMed

    Harahap, M

    1980-10-01

    Epidemiological factors and changing ecological conditions have greatly facilitated the spread of sexually transmitted diseases and led to their rising incidence in Indonesia. Gonorrhoea is at present very prevalent, and drug resistance among circulating strains of gonococci is a contributing factor. Despite medical advances in both diagnosis and treatment of sexually transmitted diseases, these are becoming commoner; unlike other communicable diseases they have so far defied efforts to control them.

  18. Vibration Propagation in Spider Webs

    NASA Astrophysics Data System (ADS)

    Hatton, Ross; Otto, Andrew; Elias, Damian

    Due to their poor eyesight, spiders rely on web vibrations for situational awareness. Web-borne vibrations are used to determine the location of prey, predators, and potential mates. The influence of web geometry and composition on web vibrations is important for understanding spider's behavior and ecology. Past studies on web vibrations have experimentally measured the frequency response of web geometries by removing threads from existing webs. The full influence of web structure and tension distribution on vibration transmission; however, has not been addressed in prior work. We have constructed physical artificial webs and computer models to better understand the effect of web structure on vibration transmission. These models provide insight into the propagation of vibrations through the webs, the frequency response of the bare web, and the influence of the spider's mass and stiffness on the vibration transmission patterns. Funded by NSF-1504428.

  19. Factors affecting finger and hand pain in workers with HAVS.

    PubMed

    House, R; Krajnak, K; Jiang, D

    2016-06-01

    Pain and its management are important aspects of hand-arm vibration syndrome (HAVS). To determine the factors associated with finger and hand pain in workers with HAVS and, specifically, to assess the impact of several neurological variables as well as the vascular component of HAVS, grip strength and age. We assessed men with HAVS at a hospital occupational medicine clinic over 2 years. Subjects scored finger and hand pain separately using the Borg Scale (0-10). The possible predictors we evaluated included the Stockholm Neurological Scale (SNS) and Stockholm Vascular Scale (SVS) stages, current perception threshold (CPT), carpal tunnel syndrome (CTS), ulnar neuropathy, grip strength and age. We carried out nerve conduction testing to confirm the presence of CTS and ulnar neuropathy and measured CPT in the fingers at 2000 Hz, 250 Hz and 5 Hz corresponding to A-beta (large myelinated), A-delta (small myelinated) and C (unmyelinated) fibres, respectively. We calculated Spearman rank correlations to examine the relation between finger and hand pain and possible predictor variables. Among the 134 subjects, the median (25th-75th percentile) pain scores were 6 (4-8) for the fingers and 5 (1-7) for the hands. We found statistically significant correlations with finger pain for the SVS stage (r = 0.239; P < 0.01) and CTS (r = 0.184; P < 0.05). The only statistically significant correlation identified for hand pain was a negative correlation with grip strength (r = -0.185; P < 0.05). Management of finger and hand pain in HAVS should focus on the correlates we have identified. © The Author 2016. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. The effect of vibration exposure during haul truck operation on grip strength, touch sensation, and balance

    PubMed Central

    Pollard, Jonisha; Porter, William; Mayton, Alan; Xu, Xueyan; Weston, Eric

    2017-01-01

    Falls from mobile equipment are reported at surface mine quarry operations each year in considerable numbers. Research shows that a preponderance of falls occur while getting on/off mobile equipment. Contributing factors to the risk of falls include the usage of ladders, exiting onto a slippery surface, and foot or hand slippage. Balance issues may also contribute to fall risks for mobile equipment operators who are exposed to whole-body vibration (WBV). For this reason, the National Institute for Occupational Safety and Health, Office of Mine Safety and Health Research conducted a study at four participating mine sites with seven haul truck operators. The purpose was to ascertain whether WBV and hand-arm vibration (HAV) exposures for quarry haul truck operators were linked to short-term decreases in performance in relation to postural stability, touch sensation threshold, and grip strength that are of crucial importance when getting on/off the trucks. WBV measures of frequency-weighted RMS accelerations (wRMS) and vibration dose value (VDV), when compared to the ISO/ANSI standards, were mostly below levels identified for the Health Guidance Caution Zone (HGCZ), although there were instances where the levels were within and above the specified Exposure Action Value. Comparably, all mean HAV levels, when compared to the ISO/ANSI standards, were below the HGCZ. For the existing conditions and equipment, no significant correlation could be identified between the WBV, HAV, postural stability, touch sensation threshold, and grip strength measures taken during this study. PMID:28220051

  1. Sexually Transmitted Diseases

    MedlinePlus

    Sexually transmitted diseases (STDs) are infections that are passed from one person to another through sexual contact. The causes of STDs ... often help with the symptoms and keep the disease under control. Correct usage of latex condoms greatly ...

  2. The vibration discomfort of standing people: evaluation of multi-axis vibration.

    PubMed

    Thuong, Olivier; Griffin, Michael J

    2015-01-01

    Few studies have investigated discomfort caused by multi-axis vibration and none has explored methods of predicting the discomfort of standing people from simultaneous fore-and-aft, lateral and vertical vibration of a floor. Using the method of magnitude estimation, 16 subjects estimated their discomfort caused by dual-axis and tri-axial motions (octave-bands centred on either 1 or 4 Hz with various magnitudes in the fore-and-aft, lateral and vertical directions) and the discomfort caused by single-axis motions. The method of predicting discomfort assumed in current standards (square-root of the sums of squares of the three components weighted according to their individual contributions to discomfort) provided reasonable predictions of the discomfort caused by multi-axis vibration. Improved predictions can be obtained for specific stimuli, but no single simple method will provide accurate predictions for all stimuli because the rate of growth of discomfort with increasing magnitude of vibration depends on the frequency and direction of vibration.

  3. VIBRATION COMPACTION

    DOEpatents

    Hauth, J.J.

    1962-07-01

    A method of compacting a powder in a metal container is described including the steps of vibrating the container at above and below the resonant frequency and also sweeping the frequency of vibration across the resonant frequency several times thereby following the change in resonant frequency caused by compaction of the powder. (AEC)

  4. Analysis and demonstration of vibration waveform reconstruction in distributed optical fiber vibration sensing system

    NASA Astrophysics Data System (ADS)

    Zhu, Hui; Shan, Xuekang; Sun, Xiaohan

    2017-10-01

    A method for reconstructing the vibration waveform from the optical time-domain backscattering pulses in the distributed optical fiber sensing system (DOFSS) is proposed, which allows for extracting and recovering the external vibration signal from the tested pulses by analog signal processing, so that can obtain vibration location and waveform simultaneously. We establish the response model of DOFSS to the external vibration and analyze the effects of system parameters on the operational performance. The main parts of the DOFSS are optimized, including delay fiber length and wavelength, to improve the sensitivity of the system. The experimental system is set up and the vibration amplitudes and reconstructed waveforms are fit well with the original driving signal. The experimental results demonstrate that the performance of vibration waveform reconstruction is good with SNR of 15 dB whenever the external vibrations with different intensities and frequencies exert on the sensing fiber.

  5. Vaginal microbiota and viral sexually transmitted diseases.

    PubMed

    Nardis, C; Mosca, L; Mastromarino, P

    2013-01-01

    Healthy vaginal microbiota is an important biological barrier to pathogenic microorganisms. When this predominantly Lactobacillus community is disrupted, decreased in abundance and replaced by different anaerobes, bacterial vaginosis (BV) may occur. BV is associated with prevalence and incidence of several sexually transmitted infections. This review provides background on BV, discusses the epidemiologic data to support a role of altered vaginal microbiota for acquisition of sexually transmitted diseases and analyzes mechanisms by which lactobacilli could counteract sexually transmitted viral infections.

  6. Vibration-translation energy transfer in vibrationally excited diatomic molecules. Ph.D. Thesis - York Univ., Toronto

    NASA Technical Reports Server (NTRS)

    Mckenzie, R. L.

    1976-01-01

    A semiclassical collision model is applied to the study of energy transfer rates between a vibrationally excited diatomic molecule and a structureless atom. The molecule is modeled as an anharmonic oscillator with a multitude of dynamically coupled vibrational states. Three main aspects in the prediction of vibrational energy transfer rates are considered. The applicability of the semiclassical model to an anharmonic oscillator is first evaluated for collinear encounters. Second, the collinear semiclassical model is applied to obtain numerical predictions of the vibrational energy transfer rate dependence on the initial vibrational state quantum number. Thermally averaged vibration-translation rate coefficients are predicted and compared with CO-He experimental values for both ground and excited initial states. The numerical model is also used as a basis for evaluating several less complete but analytic models. Third, the role of rational motion in the dynamics of vibrational energy transfer is examined. A three-dimensional semiclassical collision model is constructed with coupled rotational motion included. Energy transfer within the molecule is shown to be dominated by vibration-rotation transitions with small changes in angular momentum. The rates of vibrational energy transfer in molecules with rational frequencies that are very small in comparison to their vibrational frequency are shown to be adequately treated by the preceding collinear models.

  7. Sexually transmitted diseases among psychiatric patients in Brazil.

    PubMed

    Dutra, Maria Rita Teixeira; Campos, Lorenza Nogueira; Guimarães, Mark Drew Crosland

    2014-01-01

    Sexually transmitted diseases are still highly prevalent worldwide and represent an important public health problem. Psychiatric patients are at increased risk of sexually transmitted diseases but there are scarce published studies with representative data of this population. We sought to estimate the prevalence and correlates of self-reported sexually transmitted diseases among patients with mental illnesses under care in a national representative sample in Brazil (n=2145). More than one quarter of the sample (25.8%) reported a lifetime history of sexually transmitted disease. Multivariate analyses showed that patients with a lifetime sexually transmitted disease history were older, had history of homelessness, used more alcohol and illicit drugs, suffered violence, perceived themselves to be at greater risk for HIV and had high risk sexual behavioral: practised unprotected sex, started sexual life earlier, had more than ten sexual partners, exchanged money and/or drugs for sex and had a partner that refused to use condom. Our findings indicate a high prevalence of self-reported sexually transmitted diseases among psychiatric patients in Brazil, and emphasize the need for implementing sexually transmitted diseases prevention programs in psychiatric settings, including screening, treatment, and behavioral modification interventions. Copyright © 2013 Elsevier Editora Ltda. All rights reserved.

  8. Kinesthetic perception based on integration of motor imagery and afferent inputs from antagonistic muscles with tendon vibration.

    PubMed

    Shibata, E; Kaneko, F

    2013-04-29

    The perceptual integration of afferent inputs from two antagonistic muscles, or the perceptual integration of afferent input and motor imagery are related to the generation of a kinesthetic sensation. However, it has not been clarified how, or indeed whether, a kinesthetic perception would be generated by motor imagery if afferent inputs from two antagonistic muscles were simultaneously induced by tendon vibration. The purpose of this study was to investigate how a kinesthetic perception would be generated by motor imagery during co-vibration of the two antagonistic muscles at the same frequency. Healthy subjects participated in this experiment. Illusory movement was evoked by tendon vibration. Next, the subjects imaged wrist flexion movement simultaneously with tendon vibration. Wrist flexor and extensor muscles were vibrated according to 4 patterns such that the difference between the two vibration frequencies was zero. After each trial, the perceived movement sensations were quantified on the basis of the velocity and direction of the ipsilateral hand-tracking movements. When the difference in frequency applied to the wrist flexor and the extensor was 0Hz, no subjects perceived movements without motor imagery. However, during motor imagery, the flexion velocity of the perceived movement was higher than the flexion velocity without motor imagery. This study clarified that the afferent inputs from the muscle spindle interact with motor imagery, to evoke a kinesthetic perception, even when the difference in frequency applied to the wrist flexor and extensor was 0Hz. Furthermore, the kinesthetic perception resulting from integrations of vibration and motor imagery increased depending on the vibration frequency to the two antagonistic muscles. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Photovoltaic device having light transmitting electrically conductive stacked films

    DOEpatents

    Weber, Michael F.; Tran, Nang T.; Jeffrey, Frank R.; Gilbert, James R.; Aspen, Frank E.

    1990-07-10

    A light transmitting electrically conductive stacked film, useful as a light transmitting electrode, including a first light transmitting electrically conductive layer, having a first optical thickness, a second light transmitting layer, having a second optical thickness different from the optical thickness of the first layer, and an electrically conductive metallic layer interposed between and in initimate contact with the first and second layers.

  10. Period of vibration of axially vibrating truly nonlinear rod

    NASA Astrophysics Data System (ADS)

    Cveticanin, L.

    2016-07-01

    In this paper the axial vibration of a muscle whose fibers are parallel to the direction of muscle compression is investigated. The model is a clamped-free rod with a strongly nonlinear elastic property. Axial vibration is described by a nonlinear partial differential equation. A solution of the equation is constructed for special initial conditions by using the method of separation of variables. The partial differential equation is separated into two uncoupled strongly nonlinear second order differential equations. Both equations, with displacement function and with time function are exactly determined. Exact solutions are given in the form of inverse incomplete and inverse complete Beta function. Using boundary and initial conditions, the frequency of vibration is obtained. It has to be mentioned that the determined frequency represents the exact analytic description for the axially vibrating truly nonlinear clamped-free rod. The procedure suggested in this paper is applied for calculation of the frequency of the longissimus dorsi muscle of a cow. The influence of elasticity order and elasticity coefficient on the frequency property is tested.

  11. Vibration response of buildings to rail transit groundborne vibration

    NASA Astrophysics Data System (ADS)

    Phillips, James

    2005-09-01

    The FTA guidelines for detailed analysis and prediction of groundborne noise and vibration generated by rail transit systems are based on established empirical methods. The procedures for the measurement of vehicle/track system source strength and the attenuation of vibration as it propagates with distance through the ground are generally accepted practice at this time. However, characterization of the building response is open to debate, due in part to the wide array of building construction encountered adjacent to transit systems. Numerous measurements that have been obtained in a variety of building construction types are presented and preliminary conclusions are drawn regarding the responses of several common building types to rail transit groundborne vibration.

  12. Structure-borne sound and vibration from building-mounted wind turbines

    NASA Astrophysics Data System (ADS)

    Moorhouse, Andy; Elliott, Andy; Eastwick, Graham; Evans, Tomos; Ryan, Andy; von Hunerbein, Sabine; le Bescond, Valentin; Waddington, David

    2011-07-01

    Noise continues to be a significant factor in the development of wind energy resources. In the case of building-mounted wind turbines (BMWTs), in addition to the usual airborne sound there is the potential for occupants to be affected by structure-borne sound and vibration transmitted through the building structure. Usual methods for prediction and evaluation of noise from large and small WTs are not applicable to noise of this type. This letter describes an investigation aiming to derive a methodology for prediction of structure-borne sound and vibration inside attached dwellings. Jointly funded by three UK government departments, the work was motivated by a desire to stimulate renewable energy generation by the removal of planning restrictions where possible. A method for characterizing BMWTs as sources of structure-borne sound was first developed during a field survey of two small wind turbines under variable wind conditions. The 'source strength' was established as a function of rotor speed although a general relationship to wind speed could not be established. The influence of turbulence was also investigated. The prediction methodology, which also accounts for the sound transmission properties of the mast and supporting building, was verified in a field survey of existing installations. Significant differences in behavior and subjective character were noted between the airborne and structure-borne noise from BMWTs.

  13. Vibration sensing method and apparatus

    DOEpatents

    Barna, B.A.

    1989-04-25

    A method and apparatus for nondestructive evaluation of a structure are disclosed. Resonant audio frequency vibrations are excited in the structure to be evaluated and the vibrations are measured and characterized to obtain information about the structure. The vibrations are measured and characterized by reflecting a laser beam from the vibrating structure and directing a substantial portion of the reflected beam back into the laser device used to produce the beam which device is capable of producing an electric signal containing information about the vibration. 4 figs.

  14. Vibration sensing method and apparatus

    DOEpatents

    Barna, B.A.

    1987-07-07

    A method and apparatus for nondestructive evaluation of a structure is disclosed. Resonant audio frequency vibrations are excited in the structure to be evaluated and the vibrations are measured and characterized to obtain information about the structure. The vibrations are measured and characterized by reflecting a laser beam from the vibrating structure and directing a substantial portion of the reflected beam back into the laser device used to produce the beam which device is capable of producing an electric signal containing information about the vibration. 4 figs.

  15. Vibration sensing method and apparatus

    DOEpatents

    Barna, Basil A.

    1989-04-25

    A method and apparatus for nondestructive evaluation of a structure is disclosed. Resonant audio frequency vibrations are excited in the structure to be evaluated and the vibrations are measured and characterized to obtain information about the structure. The vibrations are measured and characterized by reflecting a laser beam from the vibrating structure and directing a substantial portion of the reflected beam back into the laser device used to produce the beam which device is capable of producing an electric signal containing information about the vibration.

  16. Quasi-steady vortical structures in vertically vibrating soap films

    NASA Astrophysics Data System (ADS)

    Vega, José M.; Higuera, F. J.; Weidman, P. D.

    1998-10-01

    An analysis of the quasi-steady streaming of the liquid in a vertically vibrated horizontal soap film is reported. The air around the soap film is seen to play a variety of roles: it transmits normal and tangential oscillatory stresses to the film, damps out Marangoni waves, and forces non-oscillatory deflection of the film and tangential motion of the liquid. Non-oscillatory volume forcing originating inside the liquid is also analysed. This forcing dominates the quasi-steady streaming when the excitation frequency is close to the eigenfrequency of a Marangoni mode of the soap film, while both volume forcing in the liquid and surface forcing of the gas on the liquid are important when no Marangoni mode resonates. Different manners by which the combined forcings can induce quasi-steady streaming motion are discussed and some numerical simulations of the quasi-steady liquid flow are presented.

  17. Electronic and vibrational spectroscopy and vibrationally mediated photodissociation of V+(OCO).

    PubMed

    Citir, Murat; Altinay, Gokhan; Metz, Ricardo B

    2006-04-20

    Electronic spectra of gas-phase V+(OCO) are measured in the near-infrared from 6050 to 7420 cm(-1) and in the visible from 15,500 to 16,560 cm(-1), using photofragment spectroscopy. The near-IR band is complex, with a 107 cm(-1) progression in the metal-ligand stretch. The visible band shows clearly resolved vibrational progressions in the metal-ligand stretch and rock, and in the OCO bend, as observed by Brucat and co-workers. A vibrational hot band gives the metal-ligand stretch frequency in the ground electronic state nu3'' = 210 cm(-1). The OCO antisymmetric stretch frequency in the ground electronic state (nu1'') is measured by using vibrationally mediated photodissociation. An IR laser vibrationally excites ions to nu1'' = 1. Vibrationally excited ions selectively dissociate following absorption of a second, visible photon at the nu1' = 1 <-- nu1'' = 1 transition. Rotational structure in the resulting vibrational action spectrum confirms that V+(OCO) is linear and gives nu1'' = 2392.0 cm(-1). The OCO antisymmetric stretch frequency in the excited electronic state is nu1' = 2368 cm(-1). Both show a blue shift from the value in free CO2, due to interaction with the metal. Larger blue shifts observed for complexes with fewer ligands agree with trends seen for larger V+(OCO)n clusters.

  18. Human annoyance, acceptability and concern as responses to vibration from the construction of Light Rapid Transit lines in residential environments.

    PubMed

    Wong-McSweeney, D; Woodcock, J S; Peris, E; Waddington, D C; Moorhouse, A T; Redel-Macías, M D

    2016-10-15

    The aim of this paper is to investigate the use of different self-reported measures for assessing the human response to environmental vibration from the construction of an urban LRT (Light Rapid Transit) system. The human response to environmental stressors such as vibration and noise is often expressed in terms of exposure-response relationships that describe annoyance as a function of the magnitude of the vibration. These relationships are often the basis of noise and vibration policy and the setting of limit values. This paper examines measures other than annoyance by expressing exposure-response relationships for vibration in terms of self-reported concern about property damage and acceptability. The exposure-response relationships for concern about property damage and for acceptability are then compared with those for annoyance. It is shown that concern about property damage occurs at vibration levels well below those where there is any risk of damage. Earlier research indicated that concern for damage is an important moderator of the annoyance induced. Acceptability, on the other hand, might be influenced by both annoyance and concern, as well as by other considerations. It is concluded that exposure-response relationships expressing acceptability as a function of vibration exposure could usefully complement existing relationships for annoyance in future policy decisions regarding environmental vibration. The results presented in this paper are derived from data collected through a socio-vibration survey (N=321) conducted for the construction of an urban LRT in the United Kingdom. Copyright © 2016. Published by Elsevier B.V.

  19. Portable vibration exciter

    NASA Technical Reports Server (NTRS)

    Beecher, L. C.; Williams, F. T.

    1970-01-01

    Gas-driven vibration exciter produces a sinusoidal excitation function controllable in frequency and in amplitude. It allows direct vibration testing of components under normal loads, removing the possibility of component damage due to high static pressure.

  20. Tunable Passive Vibration Suppressor

    NASA Technical Reports Server (NTRS)

    Boechler, Nicholas (Inventor); Dillon, Robert Peter (Inventor); Daraio, Chiara (Inventor); Davis, Gregory L. (Inventor); Shapiro, Andrew A. (Inventor); Borgonia, John Paul C. (Inventor); Kahn, Daniel Louis (Inventor)

    2016-01-01

    An apparatus and method for vibration suppression using a granular particle chain. The granular particle chain is statically compressed and the end particles of the chain are attached to a payload and vibration source. The properties of the granular particles along with the amount of static compression are chosen to provide desired filtering of vibrations.

  1. Cable Modems' Transmitted RF: A Study of SNR, Error Rates, Transmit Levels, and Trouble Call Metrics

    ERIC Educational Resources Information Center

    Tebbetts, Jo A.

    2013-01-01

    Hypotheses were developed and tested to measure the cable modems operational metrics response to a reconfiguration of the cable modems' transmitted RF applied to the CMTS. The purpose of this experiment was to compare two groups on the use of non-federal RF spectrum to determine if configuring the cable modems' transmitted RF from 25.2…

  2. Brain Regions Associated to a Kinesthetic Illusion Evoked by Watching a Video of One's Own Moving Hand

    PubMed Central

    Kaneko, Fuminari; Blanchard, Caroline; Lebar, Nicolas; Nazarian, Bruno; Kavounoudias, Anne; Romaiguère, Patricia

    2015-01-01

    It is well known that kinesthetic illusions can be induced by stimulation of several sensory systems (proprioception, touch, vision…). In this study we investigated the cerebral network underlying a kinesthetic illusion induced by visual stimulation by using functional magnetic resonance imaging (fMRI) in humans. Participants were instructed to keep their hand still while watching the video of their own moving hand (Self Hand) or that of someone else's moving hand (Other Hand). In the Self Hand condition they experienced an illusory sensation that their hand was moving whereas the Other Hand condition did not induce any kinesthetic illusion. The contrast between the Self Hand and Other Hand conditions showed significant activation in the left dorsal and ventral premotor cortices, in the left Superior and Inferior Parietal lobules, at the right Occipito-Temporal junction as well as in bilateral Insula and Putamen. Most strikingly, there was no activation in the primary motor and somatosensory cortices, whilst previous studies have reported significant activation in these regions for vibration-induced kinesthetic illusions. To our knowledge, this is the first study that indicates that humans can experience kinesthetic perception without activation in the primary motor and somatosensory areas. We conclude that under some conditions watching a video of one's own moving hand could lead to activation of a network that is usually involved in processing copies of efference, thus leading to the illusory perception that the real hand is indeed moving. PMID:26287488

  3. Brain Regions Associated to a Kinesthetic Illusion Evoked by Watching a Video of One's Own Moving Hand.

    PubMed

    Kaneko, Fuminari; Blanchard, Caroline; Lebar, Nicolas; Nazarian, Bruno; Kavounoudias, Anne; Romaiguère, Patricia

    2015-01-01

    It is well known that kinesthetic illusions can be induced by stimulation of several sensory systems (proprioception, touch, vision…). In this study we investigated the cerebral network underlying a kinesthetic illusion induced by visual stimulation by using functional magnetic resonance imaging (fMRI) in humans. Participants were instructed to keep their hand still while watching the video of their own moving hand (Self Hand) or that of someone else's moving hand (Other Hand). In the Self Hand condition they experienced an illusory sensation that their hand was moving whereas the Other Hand condition did not induce any kinesthetic illusion. The contrast between the Self Hand and Other Hand conditions showed significant activation in the left dorsal and ventral premotor cortices, in the left Superior and Inferior Parietal lobules, at the right Occipito-Temporal junction as well as in bilateral Insula and Putamen. Most strikingly, there was no activation in the primary motor and somatosensory cortices, whilst previous studies have reported significant activation in these regions for vibration-induced kinesthetic illusions. To our knowledge, this is the first study that indicates that humans can experience kinesthetic perception without activation in the primary motor and somatosensory areas. We conclude that under some conditions watching a video of one's own moving hand could lead to activation of a network that is usually involved in processing copies of efference, thus leading to the illusory perception that the real hand is indeed moving.

  4. High-Temperature Vibration Damper

    NASA Technical Reports Server (NTRS)

    Clarke, Alan; Litwin, Joel; Krauss, Harold

    1987-01-01

    Device for damping vibrations functions at temperatures up to 400 degrees F. Dampens vibrational torque loads as high as 1,000 lb-in. but compact enough to be part of helicopter rotor hub. Rotary damper absorbs energy from vibrating rod, dissipating it in turbulent motion of viscous hydraulic fluid forced by moving vanes through small orifices.

  5. Whole-body Vibration Exposure Intervention among Professional Bus and Truck Drivers: A Laboratory Evaluation of Seat-suspension Designs.

    PubMed

    Blood, Ryan P; Yost, Michael G; Camp, Janice E; Ching, Randal P

    2015-01-01

    Long-term exposure to seated whole-body vibration (WBV) is one of the leading risk factors for the development of low back disorders. Professional bus and truck drivers are regularly exposed to continuous WBV, since they spend the majority of their working hours driving heavy vehicles. This study measured WBV exposures among professional bus and truck drivers and evaluated the effects of seat-suspension designs using simulated field-collected data on a vibration table. WBV exposures were measured and compared across three different seat designs: an air-ride bus seat, an air-ride truck seat, and an electromagnetically active (EM-active) seat. Air-ride seats use a compressed-air bladder to attenuate vibrations, and they have been in operation throughout the transportation industry for many years. The EM-active seat is a relatively new design that incorporates a microprocessor-controlled actuator to dampen vibration. The vibration table simulated seven WBV exposure scenarios: four segments of vertical vibration and three scenarios that used field-collected driving data on different road surfaces-a city street, a freeway, and a section of rough roadway. The field scenarios used tri-axial WBV data that had been collected at the seat pan and at the driver's sternum, in accordance with ISO 2631-1 and 2631-5. This study found that WBV was significantly greater in the vertical direction (z-axis) than in the lateral directions (x-and y-axes) for each of the three road types and each of the three types of seats. Quantitative comparisons of the results showed that the floor-to-seat-pan transmissibility was significantly lower for the EM-active seat than for either the air-ride bus seat or the air-ride truck seat, across all three road types. This study also demonstrated that seat-suspension designs have a significant effect on the vibrations transmitted to vehicle operators, and the study's results may prove useful in designing future seat suspensions.

  6. Ground test for vibration control demonstrator

    NASA Astrophysics Data System (ADS)

    Meyer, C.; Prodigue, J.; Broux, G.; Cantinaud, O.; Poussot-Vassal, C.

    2016-09-01

    In the objective of maximizing comfort in Falcon jets, Dassault Aviation is developing an innovative vibration control technology. Vibrations of the structure are measured at several locations and sent to a dedicated high performance vibration control computer. Control laws are implemented in this computer to analyse the vibrations in real time, and then elaborate orders sent to the existing control surfaces to counteract vibrations. After detailing the technology principles, this paper focuses on the vibration control ground demonstration that was performed by Dassault Aviation in May 2015 on Falcon 7X business jet. The goal of this test was to attenuate vibrations resulting from fixed forced excitation delivered by shakers. The ground test demonstrated the capability to implement an efficient closed-loop vibration control with a significant vibration level reduction and validated the vibration control law design methodology. This successful ground test was a prerequisite before the flight test demonstration that is now being prepared. This study has been partly supported by the JTI CleanSky SFWA-ITD.

  7. Vibration analyzer

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1990-01-01

    The invention relates to monitoring circuitry for the real time detection of vibrations of a predetermined frequency and which are greater than a predetermined magnitude. The circuitry produces an instability signal in response to such detection. The circuitry is particularly adapted for detecting instabilities in rocket thrusters, but may find application with other machines such as expensive rotating machinery, or turbines. The monitoring circuitry identifies when vibration signals are present having a predetermined frequency of a multi-frequency vibration signal which has an RMS energy level greater than a predetermined magnitude. It generates an instability signal only if such a vibration signal is identified. The circuitry includes a delay circuit which responds with an alarm signal only if the instability signal continues for a predetermined time period. When used with a rocket thruster, the alarm signal may be used to cut off the thruster if such thruster is being used in flight. If the circuitry is monitoring tests of the thruster, it generates signals to change the thruster operation, for example, from pulse mode to continuous firing to determine if the instability of the thruster is sustained once it is detected.

  8. Structure, isomerism, and vibrational assignment of aluminumtrifluoroacetylacetonate. An experimental and theoretical study

    NASA Astrophysics Data System (ADS)

    Afzali, R.; Vakili, M.; Boluri, E.; Tayyari, S. F.; Nekoei, A.-R.; Hakimi-Tabar, M.; Darugar, V.

    2018-02-01

    An interpretation of the experimental IR and Raman spectra of Aluminum (III) trifluoroacetylacetonate (Al(TFAA)3) complex, which were synthesized by us, is first reported here. The charge distribution, isomerism, strength of metal-oxygen binding and vibrational spectral properties for this complex structure were theoretically investigated through population analysis, geometry optimization and harmonic frequency calculations, performed at B3LYP/6-311G* level of theory. In the population analysis, two different approaches reffered to as ;Atoms in molecules (AIM);, and ;Natural Bond Orbital (NBO); were used. According to the calculation resuls, the energy difference between the cis and trans isomers of Al(TFAA)3 is very small and indicates that both isomers coexist in the sample in comparable proportions. Comparison of the calculated frequency and intensity data with the observed IR and Raman spectra of the complex has supported this conclusion. On the other hand, comparison of the structural and vibrational spectral data of Al(TFAA)3, which were experimentally measured and calculated at B3LYP/6-311G* level, with the corresponding data of Aluminum acetylacetonate (Al(AA)3) has revealed the effects of CF3 substitution on the structural and vibrational spectral data associated with the CH3 groups in the complex structure.

  9. Interaction between vibration-evoked proprioceptive illusions and mirror-evoked visual illusions in an arm-matching task.

    PubMed

    Tsuge, Mikio; Izumizaki, Masahiko; Kigawa, Kazuyoshi; Atsumi, Takashi; Homma, Ikuo

    2012-12-01

    We studied the influence of false proprioceptive information generated by arm vibration and false visual information provided by a mirror in which subjects saw a reflection of another arm on perception of arm position, in a forearm position-matching task in right-handed subjects (n = 17). The mirror was placed between left and right arms, and arranged so that the reflected left arm appeared to the subjects to be their unseen right (reference) arm. The felt position of the right arm, indicated with a paddle, was influenced by vision of the mirror image of the left arm. If the left arm appeared flexed in the mirror, subjects felt their right arm to be more flexed than it was. Conversely, if the left arm was extended, they felt their right arm to be more extended than it was. When reference elbow flexors were vibrated at 70-80 Hz, an illusion of extension of the vibrated arm was elicited. The illusion of a more flexed reference arm evoked by seeing a mirror image of the flexed left arm was reduced by vibration. However, the illusion of extension of the right arm evoked by seeing a mirror image of the extended left arm was increased by vibration. That is, when the mirror and vibration illusions were in the same direction, they reinforced each other. However, when they were in opposite directions, they tended to cancel one another. The present study shows the interaction between proprioceptive and visual information in perception of arm position.

  10. Effect of higher frequency components and duration of vibration on bone tissue alterations in the rat-tail model

    PubMed Central

    PEELUKHANA, Srikara V.; GOENKA, Shilpi; KIM, Brian; KIM, Jay; BHATTACHARYA, Amit; STRINGER, Keith F.; BANERJEE, Rupak K.

    2015-01-01

    To formulate more accurate guidelines for musculoskeletal disorders (MSD) linked to Hand-Arm Vibration Syndrome (HAVS), delineation of the response of bone tissue under different frequencies and duration of vibration needs elucidation. Rat-tails were vibrated at 125 Hz (9 rats) and 250 Hz (9 rats), at 49 m/s2, for 1D (6 rats), 5D (6 rats) and 20D (6 rats); D=days (4 h/d). Rats in the control group (6 rats for the vibration groups; 2 each for 1D, 5D, and 20D) were left in their cages, without being subjected to any vibration. Structural and biochemical damages were quantified using empty lacunae count and nitrotyrosine signal-intensity, respectively. One-way repeated-measure mixed-model ANOVA at p<0.05 level of significance was used for analysis. In the cortical bone, structural damage quantified through empty lacunae count was significant (p<0.05) at 250 Hz (10.82 ± 0.66) in comparison to the control group (7.41 ± 0.76). The biochemical damage was significant (p<0.05) at both the 125 Hz and 250 Hz vibration frequencies. The structural damage was significant (p<0.05) at 5D for cortical bone while the trabecular bone showed significant (p<0.05) damage at 20D time point. Further, the biochemical damage increased with increase in the duration of vibration with a significant (p<0.05) damage observed at 20D time point and a near significant change (p=0.08) observed at 5D time point. Structural and biochemical changes in bone tissue are dependent upon higher vibration frequencies of 125 Hz, 250 Hz and the duration of vibration (5D, 20D). PMID:25843564

  11. Digital media and sexually transmitted infections.

    PubMed

    Gilliam, Melissa; Chor, Julie; Hill, Brandon

    2014-10-01

    Digital media, including the Internet, social networking sites, text messaging, and mobile applications, are ubiquitous among adolescents and young adults. These platforms enable users to obtain important information on a multitude of health topics, they may facilitate risk-taking behaviors, and they can be key components of health interventions. The purpose of this article is to review the recent literature on digital media and sexually transmitted infections, discussing their role in potentiating and reducing risk. This review demonstrates adolescents' use of digital media to gather information on health topics and discusses significant privacy concerns regarding using media to explore sexual health information. Although several studies demonstrate an association between social media and increased sexual risk-taking behaviors, this relationship is not fully understood. Digital media-based interventions are increasingly being developed to either reduce risk or improve management of sexually transmitted infections. As greater numbers of adolescents use digital media, the potential for these platforms to influence sexual risk-taking behaviors is significant. Additional research is needed to better understand the impact of digital media on sexually transmitted infection risk and to develop social media-based interventions to improve sexually transmitted infection outcomes.

  12. The influence of flywheel micro vibration on space camera and vibration suppression

    NASA Astrophysics Data System (ADS)

    Li, Lin; Tan, Luyang; Kong, Lin; Wang, Dong; Yang, Hongbo

    2018-02-01

    Studied the impact of flywheel micro vibration on a high resolution optical satellite that space-borne integrated. By testing the flywheel micro vibration with six-component test bench, the flywheel disturbance data is acquired. The finite element model of the satellite was established and the unit force/torque were applied at the flywheel mounting position to obtain the micro vibration data of the camera. Integrated analysis of the data of the two parts showed that the influence of flywheel micro vibration on the camera is mainly concentrated around 60-80 Hz and 170-230 Hz, the largest angular displacement of the secondary mirror along the optical axis direction is 0.04″ and the maximum angular displacement vertical to optical axis is 0.032″. After the design and installation of vibration isolator, the maximum angular displacement of the secondary mirror is 0.011″, the decay rate of root mean square value of the angular displacement is more than 50% and the maximum is 96.78%. The whole satellite was suspended to simulate the boundary condition on orbit; the imaging experiment results show that the image motion caused by the flywheel micro vibrationis less than 0.1 pixel after installing the vibration isolator.

  13. The Simulation of Magnetorheological Elastomers Adaptive Tuned Dynamic Vibration Absorber for Automobile Engine Vibration Control

    NASA Astrophysics Data System (ADS)

    Zhang, X. C.; Zhang, X. Z.; Li, W. H.; Liu, B.; Gong, X. L.; Zhang, P. Q.

    The aim of this article is to investigate the use of a Dynamic Vibration Absorber to control vibration of engine by using simulation. Traditional means of vibration control have involved the use of passive and more recently, active methods. This study is different in that it involves an adaptive component in the design of vibration absorber using magnetorheological elastomers (MREs) as the adaptive spring. MREs are kind of novel smart material whose shear modulus can be controlled by applied magnetic field. In this paper, the vibration mode of a simple model of automobile engine is simulated by Finite Element Method (FEM) analysis. Based on the analysis, the MREs Adaptive Tuned Dynamic Vibration Absorber (ATDVA) is presented to reduce the vibration of the engine. Simulation result indicate that the control frequency of ATDVA can be changed by modifing the shear modulus of MREs and the vibraion reduction efficiency of ATDVA are also evaluated by FEM analysis.

  14. Variational study on the vibrational level structure and IVR behavior of highly vibrationally excited S0 formaldehyde.

    PubMed

    Rashev, Svetoslav; Moule, David C

    2012-02-15

    We perform large scale converged variational vibrational calculations on S(0) formaldehyde up to very high excess vibrational energies (E(v)), E(v)∼17,000cm(-1), using our vibrational method, consisting of a specific search/selection/Lanczos iteration procedure. Using the same method we investigate the vibrational level structure and intramolecular vibrational redistribution (IVR) characteristics for various vibrational levels in this energy range in order to assess the onset of IVR. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Proprioceptive illusions created by vibration of one arm are altered by vibrating the other arm.

    PubMed

    Hakuta, Naoyuki; Izumizaki, Masahiko; Kigawa, Kazuyoshi; Murai, Norimitsu; Atsumi, Takashi; Homma, Ikuo

    2014-07-01

    There is some evidence that signals coming from both arms are used to determine the perceived position and movement of one arm. We examined whether the sense of position and movement of one (reference) arm is altered by increases in muscle spindle signals in the other (indicator) arm in blindfolded participants (n = 26). To increase muscle spindle discharge, we applied 70-80 Hz muscle vibration to the elbow flexors of the indicator arm. In a first experiment, proprioceptive illusions in the vibrated reference arm in a forearm position-matching task were compared between conditions in which the indicator arm elbow flexors were vibrated or not vibrated. We found that the vibration illusion of arm extension induced by vibration of reference arm elbow flexors was reduced in the presence of vibration of the indicator elbow flexors. In a second experiment, participants were asked to describe their perception of the illusion of forearm extension movements of the reference arm evoked by vibration of reference arm elbow flexors in response to on/off and off/on transitions of vibration of non-reference arm elbow flexors. When vibration of non-reference arm elbow flexors was turned on, they reported a sensation of slowing down of the illusion of the reference arm. When it was turned off, they reported a sensation of speeding up. To conclude, the present study shows that both the sense of limb position and the sense of limb movement of one arm are dependent to some extent on spindle signals coming from the other arm.

  16. 47 CFR 64.3001 - Obligation to transmit 911 calls.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Obligation to transmit 911 calls. 64.3001 Section 64.3001 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES... Obligation to transmit 911 calls. All telecommunications carriers shall transmit all 911 calls to a PSAP, to...

  17. 47 CFR 64.3001 - Obligation to transmit 911 calls.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 3 2012-10-01 2012-10-01 false Obligation to transmit 911 calls. 64.3001 Section 64.3001 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES... Obligation to transmit 911 calls. All telecommunications carriers shall transmit all 911 calls to a PSAP, to...

  18. 47 CFR 64.3001 - Obligation to transmit 911 calls.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 3 2013-10-01 2013-10-01 false Obligation to transmit 911 calls. 64.3001 Section 64.3001 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES... Obligation to transmit 911 calls. All telecommunications carriers shall transmit all 911 calls to a PSAP, to...

  19. 47 CFR 64.3001 - Obligation to transmit 911 calls.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 3 2014-10-01 2014-10-01 false Obligation to transmit 911 calls. 64.3001 Section 64.3001 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES... Obligation to transmit 911 calls. All telecommunications carriers shall transmit all 911 calls to a PSAP, to...

  20. 47 CFR 64.3001 - Obligation to transmit 911 calls.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 3 2011-10-01 2011-10-01 false Obligation to transmit 911 calls. 64.3001 Section 64.3001 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES... Obligation to transmit 911 calls. All telecommunications carriers shall transmit all 911 calls to a PSAP, to...

  1. Ocular Manifestations of Mosquito-Transmitted Diseases.

    PubMed

    Karesh, James W; Mazzoli, Robert A; Heintz, Shannon K

    2018-03-01

    Of the 3,548 known mosquito species, about 100 transmit human diseases. Mosquitoes are distributed globally throughout tropical and temperate regions where standing water sources are available for egg laying and the maturation of larva. Female mosquitoes require blood meals for egg production. This is the main pathway for disease transmission. Mosquitoes carry several pathogenic organisms responsible for significant ocular pathology and vision loss including West Nile, Rift Valley, chikungunya, dengue viruses, various encephalitis viruses, malarial parasites, Francisella tularensis, microfilarial parasites, including Dirofilaria, Wuchereria, and Brugia spp., and human botfly larvae. Health care providers may not be familiar with many of these mosquito-transmitted diseases or their associated ocular findings delaying diagnosis, treatment, and recovery of visual function. This article aims to provide an overview of the ocular manifestations associated with mosquito-transmitted diseases.

  2. Reduction of the coupling vibration between the bending vibrators of the frequency-change-type two-axis acceleration sensor

    NASA Astrophysics Data System (ADS)

    Sugawara, Sumio; Sasaki, Yoshifumi; Kudo, Subaru

    2018-07-01

    The frequency-change-type two-axis acceleration sensor uses a cross-type vibrator consisting of four bending vibrators. When coupling vibration exists between these four bending vibrators, the resonance frequency of each vibrator cannot be adjusted independently. In this study, methods of reducing the coupling vibration were investigated by finite-element analysis. A method of adjusting the length of the short arm of each vibrator was proposed for reducing the vibration. When piezoelectric ceramics were bonded to the single-sided surface of the vibrator, the method was not sufficient. Thus, the ceramics with the same dimensions were bonded to double-sided surfaces. As a result, a marked reduction was obtained in this case. Also, the linearity of the sensor characteristics was significantly improved in a small acceleration range. Accordingly, it was clarified that considering the symmetry along the thickness direction of the vibrator is very important.

  3. Visualizing the movement of the contact between vocal folds during vibration by using array-based transmission ultrasonic glottography

    PubMed Central

    Jing, Bowen; Chigan, Pengju; Ge, Zhengtong; Wu, Liang; Wang, Supin; Wan, Mingxi

    2017-01-01

    For the purpose of noninvasively visualizing the dynamics of the contact between vibrating vocal fold medial surfaces, an ultrasonic imaging method which is referred to as array-based transmission ultrasonic glottography is proposed. An array of ultrasound transducers is used to detect the ultrasound wave transmitted from one side of the vocal folds to the other side through the small-sized contact between the vocal folds. A passive acoustic mapping method is employed to visualize and locate the contact. The results of the investigation using tissue-mimicking phantoms indicate that it is feasible to use the proposed method to visualize and locate the contact between soft tissues. Furthermore, the proposed method was used for investigating the movement of the contact between the vibrating vocal folds of excised canine larynges. The results indicate that the vertical movement of the contact can be visualized as a vertical movement of a high-intensity stripe in a series of images obtained by using the proposed method. Moreover, a visualization and analysis method, which is referred to as array-based ultrasonic kymography, is presented. The velocity of the vertical movement of the contact, which is estimated from the array-based ultrasonic kymogram, could reach 0.8 m/s during the vocal fold vibration. PMID:28599522

  4. Effect of sensory and motor connectivity on hand function in pediatric hemiplegia.

    PubMed

    Gupta, Disha; Barachant, Alexandre; Gordon, Andrew M; Ferre, Claudio; Kuo, Hsing-Ching; Carmel, Jason B; Friel, Kathleen M

    2017-11-01

    We tested the hypothesis that somatosensory system injury would more strongly affect movement than motor system injury in children with unilateral cerebral palsy (USCP). This hypothesis was based on how somatosensory and corticospinal circuits adapt to injury during development; whereas the motor system can maintain connections to the impaired hand from the uninjured hemisphere, this does not occur in the somatosensory system. As a corollary, cortical injury strongly impairs sensory function, so we hypothesized that cortical lesions would impair hand function more than subcortical lesions. Twenty-four children with unilateral cerebral palsy had physiological and anatomical measures of the motor and somatosensory systems and lesion classification. Motor physiology was performed with transcranial magnetic stimulation and somatosensory physiology with vibration-evoked electroencephalographic potentials. Tractography of the corticospinal tract and the medial lemniscus was performed with diffusion tensor imaging, and lesions were classified by magnetic resonance imaging. Anatomical and physiological results were correlated with measures of hand function using 2 independent statistical methods. Children with disruptions in the somatosensory connectivity and cortical lesions had the most severe upper extremity impairments, particularly somatosensory function. Motor system connectivity was significantly correlated with bimanual function, but not unimanual function or somatosensory function. Both sensory and motor connectivity impact hand function in children with USCP. Somatosensory connectivity could be an important target for recovery of hand function in children with USCP. Ann Neurol 2017;82:766-780. © 2017 American Neurological Association.

  5. The multi-axis vibration environment and man.

    PubMed

    Lovesey, E J

    1970-12-01

    Many investigations into the effects of vibration on man have been performed since Mallock's first study of London Underground vibrations in 1902. The vibration research has tended to be confined to the vertical (heave) axis, yet recent experiments have indicated that low frequency vibration along the lateral (sway) axis has a greater adverse effect upon comfort and performance. Measurements of the vibration environments in current forms of transport including motor vehicles, hovercraft and aircraft etc have shown that appreciable quantities of vibration along all three axes exist. Further vibration research should consider the effects of multi-axis vibrations upon man rather than limit tests to single axis vibration.

  6. Graph theory applied to noise and vibration control in statistical energy analysis models.

    PubMed

    Guasch, Oriol; Cortés, Lluís

    2009-06-01

    A fundamental aspect of noise and vibration control in statistical energy analysis (SEA) models consists in first identifying and then reducing the energy flow paths between subsystems. In this work, it is proposed to make use of some results from graph theory to address both issues. On the one hand, linear and path algebras applied to adjacency matrices of SEA graphs are used to determine the existence of any order paths between subsystems, counting and labeling them, finding extremal paths, or determining the power flow contributions from groups of paths. On the other hand, a strategy is presented that makes use of graph cut algorithms to reduce the energy flow from a source subsystem to a receiver one, modifying as few internal and coupling loss factors as possible.

  7. An innovative multi dof TMD system for motorcycle handlebars designed to reduce structural vibrations and human exposure

    NASA Astrophysics Data System (ADS)

    Agostoni, S.; Cheli, F.; Leo, E.; Pezzola, M.

    2012-08-01

    Motor vehicle ride comfort is mainly affected by reciprocating engine inertia unbalances. These forces are transmitted to the driver through the main frame, the engine mounts, and the auxiliary sub systems—all components with which he physically comes into contact. On-road traction vehicle engines are mainly characterized by transient exercise. Thus, an excitation frequency range from 800 RPM (≈15 Hz for stationary vehicles) up to 15,000 RPM (≈250 Hz as a cut off condition) occurs. Several structural resonances are induced by the unbalancing forces spectrum, thus exposing the driver to amplified vibrations. The aim of this research is to reduce driver vibration exposure, by acting on the modal response of structures with which the driver comes into contact. An experimental methodology, capable of identifying local vibration modes was developed. The application of this methodology on a reference vehicle allows us to detect if/when/how the above mentioned resonances are excited. Numerical models were used to study structural modifications. In this article, a handlebar equipped with an innovative multi reciprocating tuned mass damper was optimized. All structural modifications were designed, developed and installed on a vehicle. Modal investigations were then performed in order to predict modification efficiency. Furthermore, functional solution efficiency was verified during sweep tests performed on a target vehicle, by means of a roller bench capable of replicating on-road loads. Three main investigation zones of the vehicle were detected and monitored using accelerometers: (1) engine mounts, to characterize vibration emissions; (2) bindings connecting the engine to the frame, in order to detect vibration transfer paths, with particular attention being paid to local dynamic amplifications due to compliances and (3) the terminal components with which the driver comes into contact.

  8. Vibrotactile sense and hand symptoms in blue collar workers in a manufacturing industry.

    PubMed Central

    Flodmark, B T; Lundborg, G

    1997-01-01

    OBJECTIVES: To study whether vibrotactile sense combined with questionnaires (subjective complaints) and a clinical examination (including scoring of the Stockholm workshop scale (sensorineural staging)) could serve as a screening procedure, in the health care service, for sensorineural symptoms. A group of blue collar workers exposed to vibration in a manufacturing industry (rock crushing plants) was used as the study group. Another group of workers not exposed to vibration but subjected to heavy manual work served as the control group. METHODS: Vibrotactile sense was determined. The index and the little fingers of both hands were investigated. A clinical examination was performed. Questionnaires were used for exposure data and for assessment of symptoms. RESULTS: Important findings were that impairment in vibrotactile sense correlated with impairment in grip force, cold sensitivity, and other sensorineural symptoms--such as numbness and tendency to drop items. Clinical findings such as Phalen's test and two point discrimination were related only in those workers with the poorest vibrotactile sense. There was a relation between vibrotactile sense and the Stockholm workshop scale (sensorineural staging) for the sensorineural symptoms. Muscle and joint problems were more often seen in workers with decreased vibrotactile sense. CONCLUSIONS: Tactilometry for assessment of vibrotactile sense is a useful tool in assessing and evaluating the severity of vibration induced neuromuscular symptoms and verifying the patients' clinical complaints. Heavy manual work without exposure to vibration may contribute to impairment of vibrotactile sense. The relation between impairment in vibrotactile sense and grip strength indicates that impaired sensory feedback may contribute to muscle weakness. PMID:9470896

  9. Coupled rotor/airframe vibration analysis

    NASA Technical Reports Server (NTRS)

    Sopher, R.; Studwell, R. E.; Cassarino, S.; Kottapalli, S. B. R.

    1982-01-01

    A coupled rotor/airframe vibration analysis developed as a design tool for predicting helicopter vibrations and a research tool to quantify the effects of structural properties, aerodynamic interactions, and vibration reduction devices on vehicle vibration levels is described. The analysis consists of a base program utilizing an impedance matching technique to represent the coupled rotor/airframe dynamics of the system supported by inputs from several external programs supplying sophisticated rotor and airframe aerodynamic and structural dynamic representation. The theoretical background, computer program capabilities and limited correlation results are presented in this report. Correlation results using scale model wind tunnel results show that the analysis can adequately predict trends of vibration variations with airspeed and higher harmonic control effects. Predictions of absolute values of vibration levels were found to be very sensitive to modal characteristics and results were not representative of measured values.

  10. Vibration mode imaging.

    PubMed

    Zhang, Xiaoming; Zeraati, Mohammad; Kinnick, Randall R; Greenleaf, James F; Fatemi, Mostafa

    2007-06-01

    A new method for imaging the vibration mode of an object is investigated. The radiation force of ultrasound is used to scan the object at a resonant frequency of the object. The vibration of the object is measured by laser and the resulting acoustic emission from the object is measured by a hydrophone. It is shown that the measured signal is proportional to the value of the mode shape at the focal point of the ultrasound beam. Experimental studies are carried out on a mechanical heart valve and arterial phantoms. The mode images on the valve are made by the hydrophone measurement and confirmed by finite-element method simulations. Compared with conventional B-scan imaging on arterial phantoms, the mode imaging can show not only the interface of the artery and the gelatin, but also the vibration modes of the artery. The images taken on the phantom surface suggest that an image of an interior artery can be made by vibration measurements on the surface of the body. However, the image of the artery can be improved if the vibration of the artery is measured directly. Imaging of the structure in the gelatin or tissue can be enhanced by small bubbles and contrast agents.

  11. Nonlinear convergence active vibration absorber for single and multiple frequency vibration control

    NASA Astrophysics Data System (ADS)

    Wang, Xi; Yang, Bintang; Guo, Shufeng; Zhao, Wenqiang

    2017-12-01

    This paper presents a nonlinear convergence algorithm for active dynamic undamped vibration absorber (ADUVA). The damping of absorber is ignored in this algorithm to strengthen the vibration suppressing effect and simplify the algorithm at the same time. The simulation and experimental results indicate that this nonlinear convergence ADUVA can help significantly suppress vibration caused by excitation of both single and multiple frequency. The proposed nonlinear algorithm is composed of equivalent dynamic modeling equations and frequency estimator. Both the single and multiple frequency ADUVA are mathematically imitated by the same mechanical structure with a mass body and a voice coil motor (VCM). The nonlinear convergence estimator is applied to simultaneously satisfy the requirements of fast convergence rate and small steady state frequency error, which are incompatible for linear convergence estimator. The convergence of the nonlinear algorithm is mathematically proofed, and its non-divergent characteristic is theoretically guaranteed. The vibration suppressing experiments demonstrate that the nonlinear ADUVA can accelerate the convergence rate of vibration suppressing and achieve more decrement of oscillation attenuation than the linear ADUVA.

  12. [Effect of vibrational factors on the evaluation of whole-body vibrational intensity].

    PubMed

    Suzuki, H

    1997-12-01

    The aim of this study is to obtain basic data useful to evaluate the riding comfort of railway vehicles. The apparatus used in the present experiment made it possible to simulate various vibrations of railway vehicles. Twenty-two adult subjects participated in this experiment. They were exposed to lateral vibration with varying peak and root mean square (rms) accelerations and frequencies. The types and ranges of vibrations used in this experiment approximated to the typical vibrations of railway vehicles. The subjects were asked to rate the intensity of each vibration given to them successively, using the 7-step rating scale. Results indicated that both peak and rms accelerations significantly affected for the evaluation, although the effect of frequency was not significant. As for interactions, it was found that there were significant interacting effects between frequency and peak acceleration, between frequency and rms acceleration, and between peak and rms accelerations. It was also found that the relationship between the rms acceleration and the evaluated score changed with varying peak accelerations.

  13. 14 CFR 33.33 - Vibration.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Vibration. 33.33 Section 33.33 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... vibration and without imparting excessive vibration forces to the aircraft structure. ...

  14. 14 CFR 33.33 - Vibration.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Vibration. 33.33 Section 33.33 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... vibration and without imparting excessive vibration forces to the aircraft structure. ...

  15. 14 CFR 33.33 - Vibration.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Vibration. 33.33 Section 33.33 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... vibration and without imparting excessive vibration forces to the aircraft structure. ...

  16. 14 CFR 33.33 - Vibration.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Vibration. 33.33 Section 33.33 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... vibration and without imparting excessive vibration forces to the aircraft structure. ...

  17. 14 CFR 33.33 - Vibration.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Vibration. 33.33 Section 33.33 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... vibration and without imparting excessive vibration forces to the aircraft structure. ...

  18. The Use of Body Worn Sensors for Detecting the Vibrations Acting on the Lower Back in Alpine Ski Racing.

    PubMed

    Spörri, Jörg; Kröll, Josef; Fasel, Benedikt; Aminian, Kamiar; Müller, Erich

    2017-01-01

    This study explored the use of body worn sensors to evaluate the vibrations that act on the human body in alpine ski racing from a general and a back overuse injury prevention perspective. In the course of a biomechanical field experiment, six male European Cup-level athletes each performed two runs on a typical giant slalom (GS) and slalom (SL) course, resulting in a total of 192 analyzed turns. Three-dimensional accelerations were measured by six inertial measurement units placed on the right and left shanks, right and left thighs, sacrum, and sternum. Based on these data, power spectral density (PSD; i.e., the signal's power distribution over frequency) was determined for all segments analyzed. Additionally, as a measure expressing the severity of vibration exposure, root-mean-square (RMS) acceleration acting on the lower back was calculated based on the inertial acceleration along the sacrum's longitudinal axis. In both GS and SL skiing, the PSD values of the vibrations acting at the shank were found to be largest for frequencies below 30 Hz. While being transmitted through the body, these vibrations were successively attenuated by the knee and hip joint. At the lower back (i.e., sacrum sensor), PSD values were especially pronounced for frequencies between 4 and 10 Hz, whereas a corresponding comparison between GS and SL revealed higher PSD values and larger RMS values for GS. Because vibrations in this particular range (i.e., 4 to 10 Hz) include the spine's resonant frequency and are known to increase the risk of structural deteriorations/abnormalities of the spine, they may be considered potential components of mechanisms leading to overuse injuries of the back in alpine ski racing. Accordingly, any measure to control and/or reduce such skiing-related vibrations to a minimum should be recognized and applied. In this connection, wearable sensor technologies might help to better monitor and manage the overall back overuse-relevant vibration exposure of athletes

  19. 47 CFR 22.809 - Transmitting power limits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Transmitting power limits. The transmitting power of ground and airborne mobile transmitters operating on the... Watts, except as provided in § 22.811. (b) Airborne mobile transmitters. The transmitter power output of airborne mobile transmitters must not exceed 25 Watts and must not be less than 4 Watts. ...

  20. Vibrotactile stimulation promotes embodiment of an alien hand in amputees with phantom sensations.

    PubMed

    D'Alonzo, Marco; Clemente, Francesco; Cipriani, Christian

    2015-05-01

    Tactile feedback is essential to intuitive control and to promote the sense of self-attribution of a prosthetic limb. Recent findings showed that amputees can be tricked to experience this embodiment, when synchronous and modality-matched stimuli are delivered to biological afferent structures and to an alien rubber hand. Hence, it was suggested to exploit this effect by coupling touch sensors in a prosthesis to an array of haptic tactile stimulators in the prosthetic socket. However, this approach is not clinically viable due to physical limits of current haptic devices. To address this issue we have proposed modality-mismatched stimulation and demonstrated that this promotes self-attribution of an alien hand on normally limbed subjects. In this work we investigated whether similar effects could be induced in transradial amputees with referred phantom sensations in a series of experiments fashioned after the Rubber Hand Illusion using vibrotactile stimulators. Results from three independent measures of embodiment demonstrated that vibrotactile sensory substitution elicits body-ownership of a rubber hand in transradial amputees. These results open up promising possibilities in this field; indeed miniature, safe and inexpensive vibrators could be fitted into commercially available prostheses and sockets to induce the illusion every time the prosthesis manipulates an object.