Sample records for hand-pumped picnic wells

  1. Hand-pumps as reservoirs for microbial contamination of well water

    PubMed Central

    Ferguson, Andrew S.; Mailloux, Brian J.; Ahmed, Kazi M.; van Geen, Alexander; McKay, Larry D.; Culligan, Patricia J.

    2018-01-01

    The retention and release of total coliforms and Escherichia coli was investigated in hand-pumps removed from tubewells tapping a faecally contaminated aquifer in Matlab, Bangladesh, and from a new hand-pump deliberately spiked with E. coli. All hand-pumps were connected to reservoirs of sterile water and flushed. Faecal coliforms were observed in the discharge from all three of the previously used hand-pumps, at concentrations comparable to levels measured in discharge when they were attached to the tubewells. During daily flushing of one of the previously used hand-pumps, the concentration of total coliforms in the discharge remained relatively constant (≈103 MPN/100 mL). Concentrations of E. coli in the pump discharge declined over time, but E. coli was still detectable up to 29 days after the start of flushing. In the deliberately spiked hand-pump, E. coli was observed in the discharge over 125 days (t50 = 8 days) and found to attach preferentially to elastomeric materials within the hand-pump. Attempts to disinfect both the village and new hand-pumps using shock chlorination were shown to be unsuccessful. These results demonstrate that hand-pumps can act as persistent reservoirs for microbial indicator bacteria. This could potentially influence drinking water quality and bias testing of water quality. PMID:22048430

  2. PICNIC Architecture.

    PubMed

    Saranummi, Niilo

    2005-01-01

    The PICNIC architecture aims at supporting inter-enterprise integration and the facilitation of collaboration between healthcare organisations. The concept of a Regional Health Economy (RHE) is introduced to illustrate the varying nature of inter-enterprise collaboration between healthcare organisations collaborating in providing health services to citizens and patients in a regional setting. The PICNIC architecture comprises a number of PICNIC IT Services, the interfaces between them and presents a way to assemble these into a functioning Regional Health Care Network meeting the needs and concerns of its stakeholders. The PICNIC architecture is presented through a number of views relevant to different stakeholder groups. The stakeholders of the first view are national and regional health authorities and policy makers. The view describes how the architecture enables the implementation of national and regional health policies, strategies and organisational structures. The stakeholders of the second view, the service viewpoint, are the care providers, health professionals, patients and citizens. The view describes how the architecture supports and enables regional care delivery and process management including continuity of care (shared care) and citizen-centred health services. The stakeholders of the third view, the engineering view, are those that design, build and implement the RHCN. The view comprises four sub views: software engineering, IT services engineering, security and data. The proposed architecture is founded into the main stream of how distributed computing environments are evolving. The architecture is realised using the web services approach. A number of well established technology platforms and generic standards exist that can be used to implement the software components. The software components that are specified in PICNIC are implemented in Open Source.

  3. The market for wood picnic structures.

    Treesearch

    Jerry A. Sesco

    1969-01-01

    Most of the picnic structures in six north-central states studied were constructed of wood. Service life of structure varied greatly. Vandalism and decay were the major reasons for repairing and replacing picnic tables. More than half the tables were made by the recreation agencies themselves. These results describe a market that existing and potential wood...

  4. Interchangeability of gas detection tubes and hand pumps.

    PubMed

    Haag, W R

    2001-01-01

    Users of gas detection tubes occasionally seek the convenience of using a single hand pump with different brands of tubes, to avoid the need to carry more than one pump. Several professional organizations recommend against such interchange. However, these recommendations appear to be based on a single study of pump designs that mostly are no longer in use. The present study was undertaken to determine if current hand pumps are interchangeable. Both piston-type and bellows-type hand pumps were evaluated by comparing pump flow profiles and test gas measurements with a variety of tubes. The results demonstrate that three piston hand pumps in common use (Sensidyne/Gastec GV/100, RAE Systems LP-1200, and Matheson-Kitagawa 8104-400A) are fully interchangeable. Two bellows pumps (Draeger Accuro and MSA Kwik-Draw) also are interchangeable with each other. Mixing of bellows and piston systems is often possible, but there are enough exceptions to conclude that such practice should be discouraged because it can give inaccurate readings. It is recommended that technical standards be adopted, such as total volume and an initial pump vacuum or a pump flow curve, to assess hand pump interchangeability. When two manufacturers' pumps meet the same standard and routine leak tests are conducted, interchangeability is scientifically valid and poses no risk to the end user while offering greater convenience.

  5. Puzzler Solution: Perfect Weather for a Picnic | Poster

    Cancer.gov

    It looks like we stumped you. We did not receive any correct guesses for the current Poster Puzzler, which is an image of the top of the Building 434 picnic table, with a view looking towards Building 472. This picnic table and others across campus were supplied by the NCI at Frederick Campus Improvement Committee. Building 434, located on Wood Street, is home to the staff of

  6. 50th Anniversary Employee Picnic

    NASA Image and Video Library

    2011-10-08

    Nearly 500 Stennis Space Center employees and family members took part in the facility's 50th Anniversary Employee Picnic on Oct. 8. Participants enjoyed activities ranging from historical tours to sack races.

  7. Puzzler Solution: Perfect Weather for a Picnic | Poster

    Cancer.gov

    It looks like we stumped you. We did not receive any correct guesses for the current Poster Puzzler, which is an image of the top of the Building 434 picnic table, with a view looking towards Building 472. This picnic table and others across campus were supplied by the NCI at Frederick Campus Improvement Committee. Building 434, located on Wood Street, is home to the staff of Scientific Publications, Graphics & Media (SPGM), the Central Repository, and the NCI Experimental Therapeutics Program support group, Applied and Developmental Research Directorate.

  8. Well-pump alignment system

    DOEpatents

    Drumheller, Douglas S.

    1998-01-01

    An improved well-pump for geothermal wells, an alignment system for a well-pump, and to a method for aligning a rotor and stator within a well-pump, wherein the well-pump has a whistle assembly formed at a bottom portion thereof, such that variations in the frequency of the whistle, indicating misalignment, may be monitored during pumping.

  9. Well-pump alignment system

    DOEpatents

    Drumheller, D.S.

    1998-10-20

    An improved well-pump for geothermal wells, an alignment system for a well-pump, and to a method for aligning a rotor and stator within a well-pump are disclosed, wherein the well-pump has a whistle assembly formed at a bottom portion thereof, such that variations in the frequency of the whistle, indicating misalignment, may be monitored during pumping. 6 figs.

  10. Randomised trial comparing hand expression with breast pumping for mothers of term newborns feeding poorly.

    PubMed

    Flaherman, Valerie J; Gay, Barbara; Scott, Cheryl; Avins, Andrew; Lee, Kathryn A; Newman, Thomas B

    2012-01-01

    Breast pumping or hand expression may be recommended when newborns latch or suck poorly. A recent trial found worse outcomes among mothers who used a breast pump in the early postpartum period. The objective of this study was to compare bilateral electric breast pumping to hand expression among mothers of healthy term infants feeding poorly at 12-36 h after birth. Randomised controlled trial. Well-baby nursery and postpartum unit. 68 mothers of newborns 12-36 h old who were latching or sucking poorly were randomly assigned to either 15 min of bilateral electric pumping or 15 min of hand expression. Milk transfer, maternal pain, breastfeeding confidence and breast milk expression experience (BMEE) immediately after the intervention, and breastfeeding rates at 2 months after birth. The median volume of expressed milk (range) was 0.5 (0-5) ml for hand expressing mothers and 1 (0-40) ml for pumping mothers (p=0.07). Maternal pain, breastfeeding confidence and BMEE did not differ by intervention. At 2 months, mothers assigned to hand expression were more likely to be breastfeeding (96.1%) than mothers assigned to breast pumping (72.7%) (p=0.02). Hand expression in the early postpartum period appears to improve eventual breastfeeding rates at 2 months after birth compared with breast pumping, but further research is needed to confirm this. However, in circumstances where either pumping or hand expression would be appropriate for healthy term infants 12-36 h old feeding poorly, providers should consider recommending hand expression.

  11. Surveillance of Site A and Plot M, Report for 2009.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Golchert, N. W.

    2010-04-21

    The results of the environmental surveillance program conducted at Site A/Plot M in the Palos Forest Preserve area for Calendar Year 2009 are presented. Based on the results of the 1976-1978 radiological characterization of the site, a determination was made that a surveillance program be established. The characterization study determined that very low levels of hydrogen-3 (as tritiated water) had migrated from the burial ground and were present in two nearby hand-pumped picnic wells. The current surveillance program began in 1980 and consists of sample collection and analysis of surface and subsurface water. The results of the analyses are usedmore » to monitor the migration pathway of hydrogen-3 contaminated water from the burial ground (Plot M) to the hand-pumped picnic wells and monitor for the presence of radioactive materials in the environment of the area. Hydrogen-3 in the Red Gate Woods picnic wells was still detected this year, but the average and maximum concentrations were significantly less than found earlier. Hydrogen-3 continues to be detected in a number of wells, boreholes, dolomite holes, and a surface stream. Analyses since 1984 have indicated the presence of low levels of strontium-90 in water from a number of boreholes next to Plot M. The results of the surveillance program continue to indicate that the radioactivity remaining at Site A/Plot M does not endanger the health or safety of the public visiting the site, using the picnic area, or living in the vicinity.« less

  12. Surveillance of Site A and Plot M report for 2010.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Golchert, N. W.

    2011-05-31

    The results of the environmental surveillance program conducted at Site A/Plot M in the Palos Forest Preserve area for Calendar Year 2010 are presented. Based on the results of the 1976-1978 radiological characterization of the site, a determination was made that a surveillance program be established. The characterization study determined that very low levels of hydrogen-3 (as tritiated water) had migrated from the burial ground and were present in two nearby hand-pumped picnic wells. The current surveillance program began in 1980 and consists of sample collection and analysis of surface and subsurface water. The results of the analyses are usedmore » to monitor the migration pathway of hydrogen-3 contaminated water from the burial ground (Plot M) to the hand-pumped picnic wells and monitor for the presence of radioactive materials in the environment of the area. Hydrogen-3 in the Red Gate Woods picnic wells was still detected this year, but the average and maximum concentrations were significantly less than found earlier. Hydrogen-3 continues to be detected in a number of wells, boreholes, dolomite holes, and a surface stream. Analyses since 1984 have indicated the presence of low levels of strontium-90 in water from a number of boreholes next to Plot M. The results of the surveillance program continue to indicate that the radioactivity remaining at Site A/Plot M does not endanger the health or safety of the public visiting the site, using the picnic area, or living in the vicinity.« less

  13. 104. Catalog HHistory 1, C.C.C., 73 Picnic Furniture Construction, Negative ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    104. Catalog H-History 1, C.C.C., 73 Picnic Furniture Construction, Negative No. 8821 ca. 1936 WOOD UTILIZATION. COMPLETED RUSTIC BENCH MADE BY CCC ENROLLEES AT CAMP NP-3 FOR USE AT PARKING OVERLOOKS AND PICNIC GROUNDS. NOTE SAW IN BACKGROUND USED FOR HALVING CHESTNUT. - Skyline Drive, From Front Royal, VA to Rockfish Gap, VA , Luray, Page County, VA

  14. THE PICNIC GAME: PRESENTATION OF A SITUATION OF OBSERVATION TO ASSESS FAMILY INTERACTIONS.

    PubMed

    Favez, Nicolas; Frascarolo, France; Grimard, Nathalie

    2016-05-01

    The aim of this article is to present a situation of observation designed for the assessment of family interactions: The PicNic Game (PNG). In this situation, families are invited to play at having a picnic together. This can be done with any number of children, aged from a few weeks to adolescence. A companion assessment tool, the Revised-Picnic Assessment Scale (Re-PAS), allows evaluation of interactions in the family on several dimensions. This article presents the PNG and a preliminary study of the validation of the Re-PAS dimensions in a sample of families (N = 67) with 18-month-old infants and their siblings. The PNG was well-received by the families. Construct validity of the Re-PAS was tested, first against self-reported data by mothers and fathers regarding marital satisfaction, coparenting behavior, and division of household tasks, and then against observed maternal and paternal sensitivity and controlling behaviors assessed during free-play. Results show satisfactory preliminary reliability and validity. Two contrasting cases are presented to illustrate the different interactions highlighted in the PNG. This situation is useful for researchers and clinicians, particularly as a basis for video-feedback work with the family. © 2016 Michigan Association for Infant Mental Health.

  15. 78 FR 58555 - Public Land Order No. 7821; Withdrawal of National Forest System Land for Steamboat Rock Picnic...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-24

    ...; Withdrawal of National Forest System Land for Steamboat Rock Picnic Grounds; South Dakota AGENCY: Bureau of... the Steamboat Rock Picnic Grounds within the Black Hills National Forest in South Dakota. DATES... Steamboat Rock Picnic Grounds. Order By virtue of the authority vested in the Secretary of the Interior by...

  16. 1. Deep Creek Road, picnic pavilion Great Smoky Mountains ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Deep Creek Road, picnic pavilion - Great Smoky Mountains National Park Roads & Bridges, Deep Creek Road, Between Park Boundary near Bryson City & Deep Creek Campground, Gatlinburg, Sevier County, TN

  17. PATHWAY ALIGNED WITH PICNIC PAVILION LOOKING SOUTHWEST FROM THE EASTERN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PATHWAY ALIGNED WITH PICNIC PAVILION LOOKING SOUTHWEST FROM THE EASTERN EDGE OF THE BOTANIC GARDEN - John Bartram House & Garden, 54th Street & Lindbergh Boulevard, Philadelphia, Philadelphia County, PA

  18. AmeriFlux US-Pnp Lake Mendota, Picnic Point Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Desai, Ankur

    This is the AmeriFlux version of the carbon flux data for the site US-Pnp Lake Mendota, Picnic Point Site. Site Description - The site is located on the shoreline of Lake Mendota on the rooftop of UW-Madison's Center for Limnology.

  19. Bioregenerative life support: not a picnic

    NASA Technical Reports Server (NTRS)

    Knott, W. M.

    1998-01-01

    If humans are to live permanently in space, regenerative life support systems are an enabling technology and must replace the picnic approach of taking all supplies required for each mission. These systems are classified by technologies as either physical/chemical or bioregenerative. Both of these system-types can recycle water, remove carbon dioxide, produce oxygen, and recover essential elements from waste products. Bioregenerative can also produce food, thus, making it essential if humans are to exist in space independent of earth. A solely bioregenerative life support system includes plants as a biomass production module and microbial organisms in bioreactors as a resource recovery module. In the Advanced Life Support Program, bioregenerative life support systems are being investigated through a research and technology development project which includes large scale testing as part of the Breadboard Project and human tests conducted in the soon to be constructed BioPlex facility. Research and technology development efforts are directed toward optimizing biomass productivity in controlled chambers by developing light weight, energy efficient, and automated systems; recycling liquid and solid wastes; baselining the operation of bioreactors; determining system microbial stability; assessing chemical contamination; and building models required for long term system operations. The program will include space flight studies in the near future to determine if these life support technologies will function in microgravity. When a bioregenerative system is finally incorporated into a mission, the conversion from a picnic and resupply mentality to permanent recycling and independence from earth will be complete.

  20. Geothermal down well pumping system

    NASA Technical Reports Server (NTRS)

    Matthews, H. B.; Mcbee, W. D.

    1974-01-01

    A key technical problem in the exploitation of hot water geothermal energy resources is down-well pumping to inhibit mineral precipitation, improve thermal efficiency, and enhance flow. A novel approach to this problem involves the use of a small fraction of the thermal energy of the well water to boil and super-heat a clean feedwater flow in a down-hole exchanger adjacent to the pump. This steam powers a high-speed turbine-driven pump. The exhaust steam is brought to the surface through an exhaust pipe, condensed, and recirculated. A small fraction of the high-pressure clean feedwater is diverted to lubricate the turbine pump bearings and prevent leakage of brine into the turbine-pump unit. A project demonstrating the feasibility of this approach by means of both laboratory and down-well tests is discussed.

  1. PICNIC PAVILION JUST BEYOND THE WESTERN EDGE OF THE BOTANIC ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PICNIC PAVILION JUST BEYOND THE WESTERN EDGE OF THE BOTANIC GARDEN. THIS PAVILION IS ROUGHLY LOCATED ON THE SITE OF "BARTRAM HALL," ANDREW EASTLAKE'S ITALIANATE VILLA DESIGNED BY NOTED PHILADELPHIA ARCHITECT SAMUEL SLOAN AND CONSTRUCTED IN 1850-1851 - John Bartram House & Garden, 54th Street & Lindbergh Boulevard, Philadelphia, Philadelphia County, PA

  2. Quantitative evaluation of hand cranking a roller pump in a crisis management drill.

    PubMed

    Tomizawa, Yasuko; Tokumine, Asako; Ninomiya, Shinji; Momose, Naoki; Matayoshi, Toru

    2008-01-01

    The heart-lung machines for open-heart surgery have improved over the past 50 years; they rarely break down and are almost always equipped with backup batteries. The hand-cranking procedure only becomes necessary when a pump breaks down during perfusion or after the batteries have run out. In this study, the performance of hand cranking a roller pump was quantitatively assessed by an objective method using the ECCSIM-Lite educational simulator system. A roller pump connected to an extracorporeal circuit with an oxygenator and with gravity venous drainage was used. A flow sensor unit consisting of electromagnetic sensors was used to measure arterial and venous flow rates, and a built-in pressure sensor was used to measure the water level in the reservoir. A preliminary study of continuous cranking by a team of six people was conducted as a surprise drill. This system was then used at a perfusion seminar. At the seminar, 1-min hand-cranking drills were conducted by volunteers according to a prepared scenario. The data were calculated on site and trend graphs of individual performances were given to the participants as a handout. Preliminary studies showed that each person's performance was different. Results from 1-min drills showed that good performance was not related to the number of clinical cases experienced, years of practice, or experience in hand cranking. Hand cranking to maintain the target flow rate could be achieved without practice; however, manipulating the venous return clamp requires practice. While the necessity of performing hand cranking during perfusion due to pump failure is rare, we believe that it is beneficial for perfusionists and patients to include hand-cranking practice in periodic extracorporeal circulation crisis management drills because a drill allows perfusionists to mentally rehearse the procedures should such a crisis occur.

  3. Particle size distribution of aerosols sprayed from household hand-pump sprays containing fluorine-based and silicone-based compounds.

    PubMed

    Kawakami, Tsuyoshi; Isama, Kazuo; Ikarashi, Yoshiaki

    2015-01-01

    Japan has published safety guideline on waterproof aerosol sprays. Furthermore, the Aerosol Industry Association of Japan has adopted voluntary regulations on waterproof aerosol sprays. Aerosol particles of diameter less than 10 µm are considered as "fine particles". In order to avoid acute lung injury, this size fraction should account for less than 0.6% of the sprayed aerosol particles. In contrast, the particle size distribution of aerosols released by hand-pump sprays containing fluorine-based or silicone-based compounds have not been investigated in Japan. Thus, the present study investigated the aerosol particle size distribution of 16 household hand-pump sprays. In 4 samples, the ratio of fine particles in aerosols exceeded 0.6%. This study confirmed that several hand-pump sprays available in the Japanese market can spray fine particles. Since the hand-pump sprays use water as a solvent and their ingredients may be more hydrophilic than those of aerosol sprays, the concepts related to the safety of aerosol-sprays do not apply to the hand pump sprays. Therefore, it may be required for the hand-pump spray to develop a suitable method for evaluating the toxicity and to establish the safety guideline.

  4. Effects of Pumping and Well Disinfection on Arsenic Release to Well Water

    NASA Astrophysics Data System (ADS)

    Gotkowitz, M.; Shelobolina, E.; Roden, E. E.

    2007-12-01

    In areas of northeastern Wisconsin, arsenic-bearing sulfides and iron oxides are distributed throughout a sandstone aquifer used for domestic water supplies. Aqueous arsenic concentrations exceed 10 μg/L in approximately 20% of wells in this region. These wells are often subjected to in situ chlorine disinfection to control nuisance or pathogenic bacteria. Field-based experiments investigating the effects of pumping and well disinfection showed that under non-pumping conditions, the geochemical environment in a domestic well is strongly reducing. Aqueous arsenic ranged from 10 to 18 μg/L, and the number of all tested groups of microorganisms (As(III)-reducing, Fe(III)-reducing, sulfate-reducing, As(V)-oxidizing, and aerobic microorganisms) increased 0.3 to 2.4 orders of magnitude in the well water under non-pumping conditions. The diverse populations of anaerobic and aerobic microorganisms reflect the complexity of the borehole environment. The number of Fe(III)-reducing bacteria correlates with As(III) concentrations, suggesting that microbially- facilitated reduction of iron (hydr)oxides contributes to the relatively rapid rise in aqueous arsenic observed under non-pumping conditions. Pumping the well introduces up to 1 mg/L of oxygen into the well water. The change in redox imposed by pumping decreased the number of anaerobic As(III)-reducing, Fe(III)-reducing, and sulfate-reducing microorganisms by 1 to 1.7 orders of magnitude. Aqueous arsenic also decreased during pumping (<7 μg/L), indicating that low-arsenic groundwater recharges the well. Chlorine disinfection produced strongly oxidizing conditions in the well for one hour. Treatment reduced the numbers of all microorganisms tested, but the populations recovered within three weeks. This suggests that either fresh formation water re-inoculated the well or that biofilm and scale in the well harbored some microbes from the disinfectant. Post-disinfection arsenic concentrations were similar to those measured

  5. Well pump

    DOEpatents

    Ames, Kenneth R.; Doesburg, James M.

    1987-01-01

    A well pump includes a piston and an inlet and/or outlet valve assembly of special structure. Each is formed of a body of organic polymer, preferably PTFE. Each includes a cavity in its upper portion and at least one passage leading from the cavity to the bottom of the block. A screen covers each cavity and a valve disk covers each screen. Flexible sealing flanges extend upwardly and downwardly from the periphery of the piston block. The outlet valve block has a sliding block and sealing fit with the piston rod.

  6. Oil well pump drive

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanford, G.A.

    1980-02-12

    An oil well pump drive is disclosed including a drive unit that is hydraulically actuated by a double-acting hydraulic cylinder to reciprocate vertically. An endless chain is entrained over vertically spaced sprockets carried by the unit, with one flight of the chain anchored against vertical movement and the other flight is secured to the pump polish rod so that the vertical motion imparted to the polish rod is double that hydraulically imparted to the drive unit. The polish rod load on the chain is opposed by a counterweight connected thereto by a chain extending over an elevated pulley. The outputmore » of the hydraulic pump supplying the hydraulic cylinder is cam controlled so that the motion of the drive unit is smoothly decelerated and accelerated as the unit approaches and moves from the upper and lower limits of its movement.« less

  7. Institutional Diversity in Collective Action: Investigating Successful Village Level Maintenance of Hand Pumps in Malawi

    NASA Astrophysics Data System (ADS)

    Joubert, Brian Anthony

    Providing clean water to rural communities in sub-Saharan Africa remains a challenge. Unsanitary and distant water sources cause a host of health and humanitarian problems. A common means of remedying this situation has been the donation of improved water sources, fitted with low-cost hand pumps. Due donor capacity and/ or policy most hand pumps are donated under the guise of Village Level Operation and Maintenance (VLOM). This premises the notion that recipient communities will take ownership of the new pump and as such will ensure its maintenance. To assist with this many donors carry out programs of technical repair training and the structuring of in-village leadership and management groups. The reality is that a high proportion of these pumps break down after donation and cease to work thereafter. Measures to redress technical elements of these failures through increased training or adequate distribution of spares has seen some success but failure rates remains high. This has led to a call for more attention to demand side issues, focusing on the communal aspects that may influence a village to act collectively in the maintenance of its hand pump. This thesis researched five Malawian villages where the community had maintained their hand pumps for a period of 10 or more years. These hand pumps were treated as shared resources and the literature on common-pool resources and social institutions was used as a theoretical framework. Applying these theories proved to be appropriate for analyzing the norms, conventions and forms of cooperative conduct. This allowed the research to gain insights into institutional diversity and the relationship between 'formal institutions', most often exogenous in nature, and informal' or customary collective action institutions embedded within the communities. Findings showed the emergence of three predominant themes within these successful case studies: 1) the role of leadership at varying levels and how it is embodied

  8. A method for evaluating horizontal well pumping tests.

    PubMed

    Langseth, David E; Smyth, Andrew H; May, James

    2004-01-01

    Predicting the future performance of horizontal wells under varying pumping conditions requires estimates of basic aquifer parameters, notably transmissivity and storativity. For vertical wells, there are well-established methods for estimating these parameters, typically based on either the recovery from induced head changes in a well or from the head response in observation wells to pumping in a test well. Comparable aquifer parameter estimation methods for horizontal wells have not been presented in the ground water literature. Formation parameter estimation methods based on measurements of pressure in horizontal wells have been presented in the petroleum industry literature, but these methods have limited applicability for ground water evaluation and are based on pressure measurements in only the horizontal well borehole, rather than in observation wells. This paper presents a simple and versatile method by which pumping test procedures developed for vertical wells can be applied to horizontal well pumping tests. The method presented here uses the principle of superposition to represent the horizontal well as a series of partially penetrating vertical wells. This concept is used to estimate a distance from an observation well at which a vertical well that has the same total pumping rate as the horizontal well will produce the same drawdown as the horizontal well. This equivalent distance may then be associated with an observation well for use in pumping test algorithms and type curves developed for vertical wells. The method is shown to produce good results for confined aquifers and unconfined aquifers in the absence of delayed yield response. For unconfined aquifers, the presence of delayed yield response increases the method error.

  9. Brady Geothermal Field Well Pumping Data During Deployment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurt Feigl

    Contains pumping data associated with the wells used in the 2016 Spring Campaign led partially by UW - Madison, LBNL, and LLNL scientists. The well coordinates and the depths to the pressure sensors used in the pumping wells can be found at the link "Coordinates and Sensor Depths" below.

  10. Well development by jetting using coiled tubing and simultaneous pumping.

    PubMed

    Rosberg, Jan-Erik; Bjelm, Leif

    2009-01-01

    During flow testing of a deep, 1927-m, gravel packed screen completed well, it became apparent that well development was needed to increase productivity. A hydrojetting system using coiled tubing in combination with simultaneous pumping was developed and tested and found to be successful. To verify whether the jetting improved the well, the results of a pumping test conducted before and after the jetting operation are compared. In addition, flowmeter logging and hydraulic properties obtained from pumping tests conducted during the jetting operation were also used to verify the improvements. Hydrojetting in combination with simultaneous pumping proved to be an effective cleaning method. After 100 min of pumping, around 110 m less drawdown and 15 L/s higher average flow rate were obtained compared to the values before the jetting operation. The skin factor was positive before the jetting operation and negative thereafter, thus providing additional evidence of improvements of the well. The flowmeter data also confirmed the improvements and were valuable in optimizing the jetting operation. It was also found, from the short-term pumping tests conducted during the jetting operation, that the Hantush-Jacob method for leaky confined aquifers is a valuable indicator of the well development. The combination of methods used for the well development in this case can easily be applied on other deep well projects to obtain a controlled and time-efficient well development. Copyright © 2009 The Author(s). Journal Compilation © 2009 National Ground Water Association.

  11. Analysis of pumping tests: Significance of well diameter, partial penetration, and noise

    USGS Publications Warehouse

    Heidari, M.; Ghiassi, K.; Mehnert, E.

    1999-01-01

    The nonlinear least squares (NLS) method was applied to pumping and recovery aquifer test data in confined and unconfined aquifers with finite diameter and partially penetrating pumping wells, and with partially penetrating piezometers or observation wells. It was demonstrated that noiseless and moderately noisy drawdown data from observation points located less than two saturated thicknesses of the aquifer from the pumping well produced an exact or acceptable set of parameters when the diameter of the pumping well was included in the analysis. The accuracy of the estimated parameters, particularly that of specific storage, decreased with increases in the noise level in the observed drawdown data. With consideration of the well radii, the noiseless drawdown data from the pumping well in an unconfined aquifer produced good estimates of horizontal and vertical hydraulic conductivities and specific yield, but the estimated specific storage was unacceptable. When noisy data from the pumping well were used, an acceptable set of parameters was not obtained. Further experiments with noisy drawdown data in an unconfined aquifer revealed that when the well diameter was included in the analysis, hydraulic conductivity, specific yield and vertical hydraulic conductivity may be estimated rather effectively from piezometers located over a range of distances from the pumping well. Estimation of specific storage became less reliable for piezemeters located at distances greater than the initial saturated thickness of the aquifer. Application of the NLS to field pumping and recovery data from a confined aquifer showed that the estimated parameters from the two tests were in good agreement only when the well diameter was included in the analysis. Without consideration of well radii, the estimated values of hydraulic conductivity from the pumping and recovery tests were off by a factor of four.The nonlinear least squares method was applied to pumping and recovery aquifer test data in

  12. Experience reveals ways to minimize failures in rod-pumped wells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patterson, J.C.; Bucaram, S.M.; Curfew, J.V.

    From the experience gained over the past 25 years, ARCO Oil and Gas Co. has developed recommendations to reduce equipment failure in sucker-rod pumping installations. These recommendations include equipment selection and design, operating procedures, and chemical treatment. Equipment failure and its attendant costs are extremely important in today's petroleum industry. Because rod pumping is the predominant means of artificial lift, minimizing equipment failure in rod pumped wells can have a significant impact on profitability. This compilation of recommendations comes from field locations throughout the US and other countries. The goal is to address and solve problems on a well-by-well basis.

  13. Effects of pumping strategies on pesticide concentration of a drinking water well

    NASA Astrophysics Data System (ADS)

    Aisopou, A.; Bjerg, P. L.; Binning, P. J.; Albrechtsen, H.

    2011-12-01

    Groundwater is an important source of drinking water production in many countries including Denmark. This requires high quality groundwater that meets the standards of the European Water Framework Directive. Yet as a result of agricultural activitity, deposition and previous handling, pesticides are frequently found in groundwater and can raise a substantial problem for ground water abstraction. The concentration of this contamination may vary between different layers. The heterogeneity of the subsurface geology and the depth of the drinking water well's screen are important parameters that affect the resulting contamination of the abstracted groundwater. The pesticide concentration in wells may also be affected by the pumping strategy because pumping can alter the structure of the flow field, the flowpath of water going to the well and subsequently the age of water at the well. The purpose of this study was to examine numerically the effects of pumping on pesticide contamination of drinking water wells using a reactive transport model in a hypothetical aquifer system resembling a typical Danish well field. The application history of the pesticides is crucial. This can be taken into account by assessing the effects of pumping on water age distribution along the well. Three compounds with different application histories were considered: an old banned pesticide MCPP (Mecoprop) which is mobile and relatively persistent in deeper aquifers, and a highly applied, biodegradable and strongly sorbing pesticide glyphosate, and its degradation product AMPA. A steady state flow field was first computed. A well field was then introduced and different pumping regimes were applied for a period of 180 years; a low-rate pumping, a high-rate pumping and a varying pumping regime. A constant application rate at the surface was assumed for the application period of each pesticide. The pre-abstraction age distribution of the water in the system was first estimated using a steady

  14. Shallow, non-pumped wells: a low-energy alternative for cleaning polluted groundwater.

    PubMed

    Hudak, Paul F

    2013-07-01

    This modeling study evaluated the capability of non-pumped wells with filter media for preventing contaminant plumes from migrating offsite. Linear configurations of non-pumped wells were compared to permeable reactive barriers in simulated shallow homogeneous and heterogeneous aquifers. While permeable reactive barriers enabled faster contaminant removal and shorter distances of contaminant travel, non-pumped wells also prevented offsite contaminant migration. Overall, results of this study suggest that discontinuous, linear configurations of non-pumped wells may be a viable alternative to much more costly permeable reactive barriers for preventing offsite contaminant travel in some shallow aquifers.

  15. Tucson Diversion Channel. Phase I. Sport Fields & Picnic Area. Feature Design Memorandum Number 3.

    DTIC Science & Technology

    1983-04-01

    opportunities for picnicking, a variety of field sports and court games , archery, jogging, and bicycling. d. Rapid urban growth in the Tucson metropolitan area...AD’A136 927 TUCSON DIVERSION CHANNEL PHASE I SPORT FIELDS A PICNI IC J AREA FEATURE DESIGN MEMORANDUM NUMBER 3(U) ARMY ENGINEER DISTRICT LOS ANGELES...TUCSON DIVERSION CHMNEL DESIGN EIORANDUK NO. 3 FEATURE DESIGN MNRORANDIJ PHASE I SPORT FIELDS & PICNIC AREA APRIL 1983 t1 US AM CORPS OF

  16. Terahertz Optical Gain Based on Intersubband Transitions in Optically-Pumped Semiconductor Quantum Wells: Coherent Pumped-Probe Interactions

    NASA Technical Reports Server (NTRS)

    Liu, Ansheng; Ning, Cun-Zheng

    1999-01-01

    Terahertz optical gain due to intersubband transitions in optically-pumped semiconductor quantum wells (QW's) is calculated nonperturbatively. We solve the pump- field-induced nonequilibrium distribution function for each subband of the QW system from a set of rate equations that include both intrasubband and intersubband relaxation processes. The gain arising from population inversion and stimulated Raman processes is calculated in a unified manner. We show that the coherent pump and signal wave interactions contribute significantly to the THz gain. Because of the optical Stark effect and pump-induced population redistribution, optical gain saturation at larger pump intensities is predicted.

  17. A Generic analytical solution for modelling pumping tests in wells intersecting fractures

    NASA Astrophysics Data System (ADS)

    Dewandel, Benoît; Lanini, Sandra; Lachassagne, Patrick; Maréchal, Jean-Christophe

    2018-04-01

    The behaviour of transient flow due to pumping in fractured rocks has been studied for at least the past 80 years. Analytical solutions were proposed for solving the issue of a well intersecting and pumping from one vertical, horizontal or inclined fracture in homogeneous aquifers, but their domain of application-even if covering various fracture geometries-was restricted to isotropic or anisotropic aquifers, whose potential boundaries had to be parallel or orthogonal to the fracture direction. The issue thus remains unsolved for many field cases. For example, a well intersecting and pumping a fracture in a multilayer or a dual-porosity aquifer, where intersected fractures are not necessarily parallel or orthogonal to aquifer boundaries, where several fractures with various orientations intersect the well, or the effect of pumping not only in fractures, but also in the aquifer through the screened interval of the well. Using a mathematical demonstration, we show that integrating the well-known Theis analytical solution (Theis, 1935) along the fracture axis is identical to the equally well-known analytical solution of Gringarten et al. (1974) for a uniform-flux fracture fully penetrating a homogeneous aquifer. This result implies that any existing line- or point-source solution can be used for implementing one or more discrete fractures that are intersected by the well. Several theoretical examples are presented and discussed: a single vertical fracture in a dual-porosity aquifer or in a multi-layer system (with a partially intersecting fracture); one and two inclined fractures in a leaky-aquifer system with pumping either only from the fracture(s), or also from the aquifer between fracture(s) in the screened interval of the well. For the cases with several pumping sources, analytical solutions of flowrate contribution from each individual source (fractures and well) are presented, and the drawdown behaviour according to the length of the pumped screened interval of

  18. PUMP HOUSE FOR MTR WELL NO. 1, TRA601. FLOOR PLAN, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PUMP HOUSE FOR MTR WELL NO. 1, TRA-601. FLOOR PLAN, ELEVATIONS, SECTION SHOWING WELL CASING, ROOF FRAMING PLAN. AS BUILT. WELL HOUSE FOR WELL NO. 2, TRA-602, WAS IDENTICAL IN ALL PARTICULARS EXCEPT FLOOR DIMENSIONS AND ARRANGEMENT OF PUMP AND ELECTRICAL EQUIPMENT INSIDE. IDAHO OPERATIONS OFFICE MTR-601-IDO-1, 12/1954. INL INDEX NO. 531-0601-00-396-110463, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  19. Estimating formation properties from early-time oscillatory water levels in a pumped well

    USGS Publications Warehouse

    Shapiro, A.M.; Oki, D.S.

    2000-01-01

    Hydrologists often attempt to estimate formation properties from aquifer tests for which only the hydraulic responses in a pumped well are available. Borehole storage, turbulent head losses, and borehole skin, however, can mask the hydraulic behavior of the formation inferred from the water level in the pumped well. Also, in highly permeable formations or in formations at significant depth below land surface, where there is a long column of water in the well casing, oscillatory water levels may arise during the onset of pumping to further mask formation responses in the pumped well. Usually borehole phenomena are confined to the early stages of pumping or recovery, and late-time hydraulic data can be used to estimate formation properties. In many instances, however, early-time hydraulic data provide valuable information about the formation, especially if there are interferences in the late-time data. A mathematical model and its Laplace transform solution that account for inertial influences and turbulent head losses during pumping is developed for the coupled response between the pumped borehole and the formation. The formation is assumed to be homogeneous, isotropic, of infinite areal extent, and uniform thickness, with leakage from an overlying aquifer, and the screened or open interval of the pumped well is assumed to fully penetrate the pumped aquifer. Other mathematical models of aquifer flow can also be coupled with the equations describing turbulent head losses and the inertial effects on the water column in the pumped well. The mathematical model developed in this paper is sufficiently general to consider both underdamped conditions for which oscillations arise, and overdamped conditions for which there are no oscillations. Through numerical inversion of the Laplace transform solution, type curves from the mathematical model are developed to estimate formation properties through comparison with the measured hydraulic response in the pumped well. The

  20. Investigation of Waikele well no 2401-01, Oahu, Hawaii; pumping test, well logs and water quality

    USGS Publications Warehouse

    Eyre, P.R.

    1983-01-01

    Field tests indicate that an abandoned well (No. 2401-01) near the confluence of Waikele and Kipapa Streams, Oahu, Hawaii, can be reactivated to produce potable water at a rate of 400-500 gallons per minute. Previous tests in 1946 and 1954 indicated that the well tapped the brackish transition zone which inderlies the Ghyben-Herzberg lens of the Pearl Harbor aquifer. Results of this study, based on geologic and geophysical logs of the wall, as well as on pumping test and water-quality data, indicate that the slightly brackish water produced by the well results from brackish irrigation return water. It does not appear that pumping from this well will cause seawater upconing or intrusion. (USGS)

  1. Rationale and design of PICNIC study: nutritional intervention program in hospitalized patients with heart failure who are malnourished.

    PubMed

    Gámez-López, Antonio L; Bonilla-Palomas, Juan L; Anguita-Sánchez, Manuel; Moreno-Conde, Mirian; López-Ibáñez, Cristina; Alhambra-Expósito, Rosa; Castillo-Domínguez, Juan C; Villar-Ráez, Antonia; Suárez de Lezo, José

    2014-04-01

    Hospitalized patients with heart failure who are malnourished present a worse prognosis than those with an adequate nutritional status. It is unknown whether a nutritional intervention can modify the prognosis of these patients. The aim of this study is to assess the efficacy of a nutritional intervention on morbidity and mortality in hospitalized patients with heart failure who are malnourished. PICNIC is a multicentre, randomized, controlled trial in which hospitalized patients with heart failure and malnutrition, as defined by the Mini Nutritional Assessment, are randomly assigned to conventional management of heart failure or conventional management of heart failure and an individualized nutritional intervention consisting of 3 points: optimization of diet, specific recommendations, and prescription, if deemed necessary, of nutritional supplements. A sample size of 182 patients for a maximum follow-up of 12 months has been estimated. The primary endpoint is time to death from any cause or rehospitalization because of heart failure. Analysis is by intention to treat. PICNIC study will determine the prognostic impact of a nutritional intervention in hospitalized patients with heart failure who are malnourished. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  2. GAS-PHASE AND PARTICULATE EMISSIONS DURING APPLICATION OF A WATER-BASED CLEANER WITH A HAND-PUMP SPRAYER

    EPA Science Inventory

    The paper gives results of tests in a controlled environment test room to measure concentrations of 2-butoxyethanol and particles during application of a cleaner to realistic surfaces (counter tops, glass, walls). (NOTE: Users of water-based cleaners applied with hand-pump spray...

  3. Diode-Laser Pumped Far-Infrared Local Oscillator Based on Semiconductor Quantum Wells

    NASA Technical Reports Server (NTRS)

    Kolokolov, K.; Li, J.; Ning, C. Z.; Larrabee, D. C.; Tang, J.; Khodaparast, G.; Kono, J.; Sasa, S.; Inoue, M.; Biegel, Bryan A. (Technical Monitor)

    2002-01-01

    The contents include: 1) Tetrahertz Field: A Technology Gap; 2) Existing THZ Sources and Shortcomings; 3) Applications of A THZ Laser; 4) Previous Optical Pumped LW Generations; 5) Optically Pumped Sb based Intersubband Generation Whys; 6) InGaAs/InP/AlAsSb QWs; 7) Raman Enhanced Optical Gain; 8) Pump Intensity Dependence of THZ Gain; 9) Pump-Probe Interaction Induced Raman Shift; 10) THZ Laser Gain in InGaAs/InP/AlAsSb QWs; 11) Diode-Laser Pumped Difference Frequency Generation (InGaAs/InP/AlAsSb QWs); 12) 6.1 Angstrom Semiconductor Quantum Wells; 13) InAs/GaSb/AlSb Nanostructures; 14) InAs/AlSb Double QWs: DFG Scheme; 15) Sb-Based Triple QWs: Laser Scheme; and 16) Exciton State Pumped THZ Generation. This paper is presented in viewgraph form.

  4. Coherent Pump-Probe Interactions and Terahertz Intersubband Gain in Semiconductor Quantum Wells

    NASA Technical Reports Server (NTRS)

    Liu, Ansheng; Ning, Cun-Zheng

    1999-01-01

    In recent years there has been considerable interest in intersubband-transition-based infrared semiconductor quantum well (QW) lasers because of their potential applications. In the mid-infrared range, both electrically-injected quantum cascade lasers [1] and optically-pumped multiple QW lasers [2] have been experimentally realized. In these studies, optical gain is due to population inversion between the lasing subbands. It was also proposed that stimulated Raman scattering in QW systems can produce net infrared optical gain [3j. In such a nonlinear optical scheme, the appearance of optical gain that may lead to intersubband Raman lasers does not rely on the population inversion. Since, in tile resonant Raman process (Raman gain is the largest in this case), the pump field induces population redistribution among subbands in the QW s ystem, it seems that a realistic estimate of the optical gain has to include this effect. Perturbative calculations used in the previous work [3] may overestimate the Raman gain. In this paper we present a nonperturbative calculation of terahertz gain of optically-pumped semiconductor step quantum wells. Limiting optical transitions within the conduction band of QW, we solve the pump-field-induced nonequilibrium distribution function for each subband of the QW system from a set of coupled rate equations. Both intrasubband and intersubband relaxation processes in the quantum well system are included. Taking into account the coherent interactions between pump and THz (signal) waves, we we derive the susceptibility of the QW system for the THz field. For a GaAs/AlGaAs step QW, we calculate the Thz gain spectrum for different pump frequencies and intensities. Under moderately strong pumping (approximately 0.3 MW/sq cm), a significant THz gain (approximately 300/m) is predicted. It is also shown that the coherent wave interactions (resonant stimulated Raman processes) contribute significantly to the THz gain.

  5. Pumping tests of well Campbell et al. No. 2, Gila Hot Springs, Grant County, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwab, G.E.; Summers, W.K.; Colpitts, R.M. Jr.

    1982-03-01

    Well Campbell et al. No. 2 near Gila Hot Springs in southwestern New Mexico (Section 5, Township 13 South, Range 13 West) was pumped for a five-step test and a 48-hour constant-rate test during October 1981. Measurements included depth to water in the pumping well and two observation wells, and discharge rates at the pumping well and two springs. The water level in the pumping well responded during both tests. However, water-level changes in the observation wells were too small for analytical use and discharge rates from the springs showed no change. Chemical analyses of water samples collected from twomore » springs and the pumping well show very similar water chemistries. Estimates of hydraulic properties show transmissivity from 12,000 to 14,000 gpd/ft and a storativity of 0.05. Combining these parameters with well data gives the first-year optimum discharge rate as 50 gpm with 20 feet of drawdown. Pumping this well at 50 gpm for forty years should produce only small water-level changes in wells a few hundred feet away. It would diminish the flow of the springs, and for planning purposes the combined discharge of the springs and well should be considered constant.« less

  6. Seawater Upconing Under a Pumping Horizontal Well in a Confined Coastal Aquifer

    NASA Astrophysics Data System (ADS)

    Sun, D.; Zhan, H.

    2003-12-01

    Coastal margins are one of the nation­_s greatest natural resources and economic assets. Due to increasing concentration of human settlements and economic activities in the coastal margins, it is critical to find better technologies of managing the coastal groundwater resources. Coastal aquifers always have saline water underneath the fresh water. This phenomenon substantially limits the groundwater pumping rates using traditional vertical wells because of the upconing of the fresh/saline water interfaces and the potential of sea water intrusion. With the advancement of horizontal well technology, we propose to use long-screen (kilometers) horizontal wells in coastal aquifers to increase groundwater supply and prevent sea water intrusion into those wells. In this study, we have developed two mathematical models to predict the equilibrium location of upconed sharp interfaces due to pumping horizontal wells based on the linear model of Muskat (1982) and the non-linear model of Dagan and Bear (1968) which described the upcoming due to a partially penetrating vertical pumping well. The horizontal well solution is obtained by integrating the point sink solution along the horizontal well axis. The linear solution based on Muskat­_s model (1982) is acquired by neglecting the pressure field variation caused by the change of the fresh/saline water interface, while the nonlinear solution includes that variation. The computed interface profiles based on these two models are compared with those of vertical wells. The critical pumping rate is calculated and the sensitivity of the interface profile on aquifer anisotropy, horizontal well depth, and horizontal well length is tested. References: G. Dagan and J. Bear, Solving the problem of local interface upcoming in a coastal aquifer by the method of small perturbations, J. Hydraulic Research, 6, 15-44, 1968. Muskat, M, The flow of homogeneous Fluids Through Porous Media, International Human Resources Development Corporation

  7. Well hydraulics in pumping tests with exponentially decayed rates of abstraction in confined aquifers

    NASA Astrophysics Data System (ADS)

    Wen, Zhang; Zhan, Hongbin; Wang, Quanrong; Liang, Xing; Ma, Teng; Chen, Chen

    2017-05-01

    Actual field pumping tests often involve variable pumping rates which cannot be handled by the classical constant-rate or constant-head test models, and often require a convolution process to interpret the test data. In this study, we proposed a semi-analytical model considering an exponentially decreasing pumping rate started at a certain (higher) rate and eventually stabilized at a certain (lower) rate for cases with or without wellbore storage. A striking new feature of the pumping test with an exponentially decayed rate is that the drawdowns will decrease over a certain period of time during intermediate pumping stage, which has never been seen before in constant-rate or constant-head pumping tests. It was found that the drawdown-time curve associated with an exponentially decayed pumping rate function was bounded by two asymptotic curves of the constant-rate tests with rates equaling to the starting and stabilizing rates, respectively. The wellbore storage must be considered for a pumping test without an observation well (single-well test). Based on such characteristics of the time-drawdown curve, we developed a new method to estimate the aquifer parameters by using the genetic algorithm.

  8. Injection System for Multi-Well Injection Using a Single Pump

    PubMed Central

    Wovkulich, Karen; Stute, Martin; Protus, Thomas J.; Mailloux, Brian J.; Chillrud, Steven N.

    2015-01-01

    Many hydrological and geochemical studies rely on data resulting from injection of tracers and chemicals into groundwater wells. The even distribution of liquids to multiple injection points can be challenging or expensive, especially when using multiple pumps. An injection system was designed using one chemical metering pump to evenly distribute the desired influent simultaneously to 15 individual injection points through an injection manifold. The system was constructed with only one metal part contacting the fluid due to the low pH of the injection solutions. The injection manifold system was used during a three-month pilot scale injection experiment at the Vineland Chemical Company Superfund site. During the two injection phases of the experiment (Phase I = 0.27 L/min total flow, Phase II = 0.56 L/min total flow), flow measurements were made 20 times over three months; an even distribution of flow to each injection well was maintained (RSD <4%). This durable system is expandable to at least 16 injection points and should be adaptable to other injection experiments that require distribution of air-stable liquids to multiple injection points with a single pump. PMID:26140014

  9. Optimizing the well pumping rate and its distance from a stream

    NASA Astrophysics Data System (ADS)

    Abdel-Hafez, M. H.; Ogden, F. L.

    2008-12-01

    Both ground water and surface water are very important component of the water resources. Since they are coupled systems in riparian areas, management strategies that neglect interactions between them penalize senior surface water rights to the benefit of junior ground water rights holders in the prior appropriation rights system. Water rights managers face a problem in deciding which wells need to be shut down and when, in the case of depleted stream flow. A simulation model representing a combined hypothetical aquifer and stream has been developed using MODFLOW 2000 to capture parameter sensitivity, test management strategies and guide field data collection campaigns to support modeling. An optimization approach has been applied to optimize both the well distance from the stream and the maximum pumping rate that does not affect the stream discharge downstream the pumping wells. Conjunctive management can be modeled by coupling the numerical simulation model with the optimization techniques using the response matrix technique. The response matrix can be obtained by calculating the response coefficient for each well and stream. The main assumption of the response matrix technique is that the amount of water out of the stream to the aquifer is linearly proportional to the well pumping rate (Barlow et al. 2003). The results are presented in dimensionless form, which can be used by the water managers to solve conflicts between surface water and ground water holders by making the appropriate decision to choose which well need to be shut down first.

  10. Continuous pumping of steam into the wells of the Camp Pirital deposit in Venezuela

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lanfranchi, E.A.

    The Campo Pirital deposit was opened in 1956. The maximal oil extraction occured in 1961 and by 1965, it was reduced. Steam pumping was begun in 1965. The extraction rose to 731 cubic meters per day by May, 1967 and by 1976, the extraction again fell. The introduction of a test plan for continuous steam pumping into the sand collectors was begun in July, 1976. Loose carbonate, finely grained sandstones of pale gray and gray to green color, interlayered by clay and carbonate lutites, are typical deposits for this region. The test plan is a model of 9 wells (onemore » pumping (N) well and eight operational (E) wells). The operational wells are located at a distance of 34.4 to 187 meters from the pumping well. At the end of five years of use of the test plan, the following positive results may be discussed: the flow rates of the wells remained constant, no steam blowout was noted in the wells, the front of heat is shifted to the upper part of the structure and so on. Therefore, the test project is recommended for expansion and three new installations will be positioned near the first.« less

  11. IMPACT OF SUBMERSIBLE PUMPS ON PB CONSTITUENTS IN RESIDENTIAL WELLS

    EPA Science Inventory

    Dissolved lead in 51 domestic wells screened from 18 m to 48 m in glacial tills and outwash deposits were examined, from archived samples collected during 2001-2004, in conjunction with respective submersible pump characteristics. Pb concentrations of these residential water supp...

  12. Near-Infrared Laser Pumped Intersubband THz Laser Gain in InGaAs-AlAsSb-InP Quantum Wells

    NASA Technical Reports Server (NTRS)

    Liu, An-Sheng; Ning, Cun-Zheng

    1999-01-01

    We investigate the possibility of using InGaAs-AlAsSb-InP coupled quantum wells to generate THz radiation by means of intersubband optical pumping. We show that large conduction band offsets of these quantum wells make it possible to use conventional near-infrared diode lasers around 1.55 micron as pump sources. Taking into account the pump-probe coherent interaction and the optical nonlinearity for the pump field, we calculate the THz gain of the quantum well structure. We show that resonant Raman scattering enhances the THz gain at low and moderate optical pumping levels. When the pump intensity is strong, the THz gain is reduced by pump-induced population redistribution and pump-probe coherent interactions.

  13. Pump Operation Workshop. Third Edition (Revised).

    ERIC Educational Resources Information Center

    Ontario Ministry of the Environment, Toronto.

    Presented is the learner's manual for a five-day workshop designed to supplement the skills of water and wastewater treatment personnel. The program consists of lecture-discussions and hands-on sessions covering the operation of water and wastewater pumps. Areas addressed include: material pumped, pump systems, types of pumps, pump controls,…

  14. Exciton Absorption in Semiconductor Quantum Wells Driven by a Strong Intersubband Pump Field

    NASA Technical Reports Server (NTRS)

    Liu, Ansheng; Ning, Cun-Zheng

    1999-01-01

    Optical interband excitonic absorption of semiconductor quantum wells (QW's) driven by a coherent pump field is investigated based on semiconductor Bloch equations. The pump field has a photon energy close to the intersubband spacing between the first two conduction subbands in the QW's. An external weak optical field probes the interband transition. The excitonic effects and pump-induced population redistribution within the conduction subbands in the QW system are included. When the density of the electron-hole pairs in the QW structure is low, the pump field induces an Autler-Townes splitting of the exciton absorption spectrum. The split size and the peak positions of the absorption doublet depend not only on the pump frequency and intensity but also on the carrier density. As the density of the electron-hole pairs is increased, the split contrast (the ratio between the maximum and minimum values) is decreased because the exciton effect is suppressed at higher densities due to the many-body screening.

  15. Pumping tests in networks of multilevel sampling wells: Motivation and methodology

    USGS Publications Warehouse

    Butler, J.J.; McElwee, C.D.; Bohling, Geoffrey C.

    1999-01-01

    The identification of spatial variations in hydraulic conductivity (K) on a scale of relevance for transport investigations has proven to be a considerable challenge. Recently, a new field method for the estimation of interwell variations in K has been proposed. This method, hydraulic tomography, essentially consists of a series of short‐term pumping tests performed in a tomographic‐like arrangement. In order to fully realize the potential of this approach, information about lateral and vertical variations in pumping‐induced head changes (drawdown) is required with detail that has previously been unobtainable in the field. Pumping tests performed in networks of multilevel sampling (MLS) wells can provide data of the needed density if drawdown can accurately and rapidly be measured in the small‐diameter tubing used in such wells. Field and laboratory experiments show that accurate transient drawdown data can be obtained in the small‐diameter MLS tubing either directly with miniature fiber‐optic pressure sensors or indirectly using air‐pressure transducers. As with data from many types of hydraulic tests, the quality of drawdown measurements from MLS tubing is quite dependent on the effectiveness of well development activities. Since MLS ports of the standard design are prone to clogging and are difficult to develop, alternate designs are necessary to ensure accurate drawdown measurements. Initial field experiments indicate that drawdown measurements obtained from pumping tests performed in MLS networks have considerable potential for providing valuable information about spatial variations in hydraulic conductivity.

  16. Domestic wells have high probability of pumping septic tank leachate

    NASA Astrophysics Data System (ADS)

    Horn, J. E.; Harter, T.

    2011-06-01

    Onsite wastewater treatment systems such as septic systems are common in rural and semi-rural areas around the world; in the US, about 25-30 % of households are served by a septic system and a private drinking water well. Site-specific conditions and local groundwater flow are often ignored when installing septic systems and wells. Particularly in areas with small lots, thus a high septic system density, these typically shallow wells are prone to contamination by septic system leachate. Typically, mass balance approaches are used to determine a maximum septic system density that would prevent contamination of the aquifer. In this study, we estimate the probability of a well pumping partially septic system leachate. A detailed groundwater and transport model is used to calculate the capture zone of a typical drinking water well. A spatial probability analysis is performed to assess the probability that a capture zone overlaps with a septic system drainfield depending on aquifer properties, lot and drainfield size. We show that a high septic system density poses a high probability of pumping septic system leachate. The hydraulic conductivity of the aquifer has a strong influence on the intersection probability. We conclude that mass balances calculations applied on a regional scale underestimate the contamination risk of individual drinking water wells by septic systems. This is particularly relevant for contaminants released at high concentrations, for substances which experience limited attenuation, and those being harmful even in low concentrations.

  17. The Causes and Prevention Measures of Stuck Pump Phenomenon of Rod-pumped Well in CBM Field

    NASA Astrophysics Data System (ADS)

    Yonggui, Mei

    2018-02-01

    In the process of CBM field exploitation, in order to realize the drainage equipment to work continuous stably, the article pays attention to study and solve the stuck pump problem, and aim of reducing reservoir damage and lowing production costs. Through coal particles stuck pump experiment and sediment composition analysis, we find out five primary cause of stuck pump phenomenon: sand from coal seam, sediment from ground, iron corrosion, iron scrap caused by eccentric wear, coal cake. According to stuck pump mechanism, the article puts forward 8 measures to prevent stuck pump phenomenon, and the measures are focused on technology optimization, operation management and drainage process control. After 7 years production practice, the yearly stuck pump rate has dropped from 8.9% to 1.2%, and the pump inspection period has prolonged 2 times. The experiment result shows that pure coal particles cannot cause stuck pump, but sand, scrap iron, and iron corrosion are the primary cause of stuck pump. The article study and design the new pipe string structure that the bottom of the pipe string is open. This kind of pipe string applied the sedimentation terminal velocity theory to solve the stuck pump phenomenon, and it can be widely used in CBM drainage development.

  18. Simulated effects of pumping irrigation wells on ground-water levels in western Saginaw County, Michigan

    USGS Publications Warehouse

    Hoard, Christopher J.; Westjohn, David B.

    2001-01-01

    Success of agriculture in many areas of Michigan relies on withdrawal of large quantities of ground water for irrigation. In some areas of the State, water-level declines associated with large ground-water withdrawals may adversely affect nearby residential wells. Residential wells in several areas of Saginaw County, in Michigan's east-central Lower Peninsula, recently went dry shortly after irrigation of crop lands commenced; many of these wells also went dry during last year's agricultural cycle (summer 2000). In September 2000, residential wells that had been dry returned to function after cessation of pumping from large-capacity irrigation wells. To evaluate possible effects of groundwater withdrawals from irrigation wells on residential wells, the U.S. Geological Survey used hydrogeologic data including aquifer tests, water-level records, geologic logs, and numerical models to determine whether water-level declines and the withdrawal of ground water for agricultural irrigation are related. Numerical simulations based on representative irrigation well pumping volumes and a 3-month irrigation period indicate water-level declines that range from 5.3 to 20 feet, 2.8 to 12 feet and 1.7 to 6.9 feet at distances of about 0.5, 1.5 and 3 miles from irrigation wells, respectively. Residential wells that are equipped with shallow jet pumps and that are within 0.5 miles of irrigation wells would likely experience reduced yield or loss of yield during peak periods of irrigation. The actual 1 extent that irrigation pumping cause reduced function of residential wells, however, cannot be fully predicted on the basis of the data analyzed because many _other factors may be adversely affecting the yield of residential wells.

  19. 46 CFR 119.520 - Bilge pumps.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PASSENGERS OR WITH OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS MACHINERY INSTALLATION Bilge and... power pump is an acceptable alternative to a hand pump if it is supplied by a source independent of the first power bilge pump. ...

  20. 46 CFR 119.520 - Bilge pumps.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PASSENGERS OR WITH OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS MACHINERY INSTALLATION Bilge and... power pump is an acceptable alternative to a hand pump if it is supplied by a source independent of the first power bilge pump. ...

  1. 46 CFR 119.520 - Bilge pumps.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... PASSENGERS OR WITH OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS MACHINERY INSTALLATION Bilge and... power pump is an acceptable alternative to a hand pump if it is supplied by a source independent of the first power bilge pump. ...

  2. 46 CFR 119.520 - Bilge pumps.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PASSENGERS OR WITH OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS MACHINERY INSTALLATION Bilge and... power pump is an acceptable alternative to a hand pump if it is supplied by a source independent of the first power bilge pump. ...

  3. 46 CFR 119.520 - Bilge pumps.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PASSENGERS OR WITH OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS MACHINERY INSTALLATION Bilge and... power pump is an acceptable alternative to a hand pump if it is supplied by a source independent of the first power bilge pump. ...

  4. 46 CFR 169.654 - Bilge pumps.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Machinery and... bilge pump or fixed power bilge pump having a minimum capacity of 10 gpm. If a fixed hand pump is... section, vessels of 40 feet but less than 65 feet must have a fixed power bilge pump having a minimum...

  5. 46 CFR 169.654 - Bilge pumps.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Machinery and... bilge pump or fixed power bilge pump having a minimum capacity of 10 gpm. If a fixed hand pump is... section, vessels of 40 feet but less than 65 feet must have a fixed power bilge pump having a minimum...

  6. 46 CFR 169.654 - Bilge pumps.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Machinery and... bilge pump or fixed power bilge pump having a minimum capacity of 10 gpm. If a fixed hand pump is... section, vessels of 40 feet but less than 65 feet must have a fixed power bilge pump having a minimum...

  7. 46 CFR 169.654 - Bilge pumps.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Machinery and... bilge pump or fixed power bilge pump having a minimum capacity of 10 gpm. If a fixed hand pump is... section, vessels of 40 feet but less than 65 feet must have a fixed power bilge pump having a minimum...

  8. 46 CFR 169.654 - Bilge pumps.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Machinery and... bilge pump or fixed power bilge pump having a minimum capacity of 10 gpm. If a fixed hand pump is... section, vessels of 40 feet but less than 65 feet must have a fixed power bilge pump having a minimum...

  9. Fluid Dynamic Analysis of Hand-Pump Infuser and UROMAT Endoscopic Automatic System for Irrigation Through a Flexible Ureteroscope.

    PubMed

    Lama, Daniel J; Owyong, Michael; Parkhomenko, Egor; Patel, Roshan M; Landman, Jaime; Clayman, Ralph V

    2018-05-01

    To evaluate the flow characteristics produced by a manual and automated-pump irrigation system connected to a flexible ureteroscope. An in vitro analysis of a manual hand-pump infuser (HP) and the UROMAT Endoscopic Automatic System for Irrigation ® (E.A.S.I.) pump was performed. Standard irrigation tubing was used to connect a three-way valve to a flexible ureteroscope, the irrigation system, and a digital manometer. Flow rate and irrigation pressure measurements were recorded over a 15-minute period using pressure settings of 150 and 200 mm Hg for both irrigation pump systems. Once the HP was inflated to the initial pressure, it was not reinflated over the course of the trial. Data were collected with the working channel unoccupied and with placement of a 200 μm (0.6F) holmium laser fiber, 1.7F nitinol stone retrieval basket, or 2.67F guidewire. The difference in pressure measured at the site of inflow of irrigation to the ureteroscope was significantly greater using the HP compared to the E.A.S.I. pump at pressure settings of 150 mm Hg with and without the use of ureteroscopic instrumentation (p < 0.001), and at 200 mm Hg with instrumentation in the working channel (p < 0.01). There was no significant difference in the flow rate of irrigation through the open-channel ureteroscope over the course of 5 minutes between the two pump systems. The flow rates of irrigation produced by the HP and the E.A.S.I. pump are similar at pressures of 150 and 200 mm Hg irrespective of the occupancy of a ureteroscope's working channel during the first 5-minutes of irrigation. Irrigation pressure at the entry site of the ureteroscope is subject to significant variability with use of the HP compared to the E.A.S.I. pump irrigation system.

  10. Settlements around pumping wells: Analysis of influential factors and a simple calculation procedure

    NASA Astrophysics Data System (ADS)

    Pujades, Estanislao; De Simone, Silvia; Carrera, Jesus; Vázquez-Suñé, Enric; Jurado, Anna

    2017-05-01

    Estimated and measured settlements caused by pumping rarely agree. Several reasons could explain this mismatch, including the influence of layering, the mechanical parameters used in the predictions, or the relationship between settlements and drawdown. We analyze the influence of the above issues by investigating the mechanical response of pumped elastic porous media under different conditions. A radially symmetric conceptual model is considered and several hydro-mechanical simulations are performed varying the boundary conditions, the size of the modeled domain and the presence or not of an overlying layer. The simplicity of the considered problem allows us to compare our results with existing analytical solutions, to identify the role of each variable on pumping settlements and to generalize the results. The most relevant results are as follows: (1) settlements are proportional to drawdown only outside a circle of radius equal to 0.7 times the thickness of the pumped porous medium; inside, they are virtually constant, which leads to two simple procedures for computing pumping settlements. (2) Poorly conductive layers located above (or below) a pumped porous medium (with higher hydraulic conductivity) reduce and smooth settlements. (3) Boundary constraints affect the local specific storage coefficient and the displacements occurred. (4) The specific storage coefficient evaluated by interpreting pumping tests with the Cooper and Jacob method (1946) leads to overestimation of the actual Young's Modulus of the soil. The main conclusion is that settlements are less differential than expected near pumping wells. Still, they must always be evaluated acknowledging the nature of layering, the boundary constraints and carefully selecting the mechanical parameters of the soil.

  11. Solute Concentration at a Pumping Well in Non-Gaussian Random Aquifers under Time-Varying Operational Schedules

    NASA Astrophysics Data System (ADS)

    Libera, A.; de Barros, F.; Riva, M.; Guadagnini, A.

    2016-12-01

    Managing contaminated groundwater systems is an arduous task for multiple reasons. First, subsurface hydraulic properties are heterogeneous and the high costs associated with site characterization leads to data scarcity (therefore, model predictions are uncertain). Second, it is common for water agencies to schedule groundwater extraction through a temporal sequence of pumping rates to maximize the benefits to anthropogenic activities and minimize the environmental footprint of the withdrawal operations. The temporal variability in pumping rates and aquifer heterogeneity affect dilution rates of contaminant plumes and chemical concentration breakthrough curves (BTCs) at the well. While contaminant transport under steady-state pumping is widely studied, the manner in which a given time-varying pumping schedule affects contaminant plume behavior is tackled only marginally. At the same time, most studies focus on the impact of Gaussian random hydraulic conductivity (K) fields on transport. Here, we systematically analyze the significance of the random space function (RSF) model characterizing K in the presence of distinct pumping operations on the uncertainty of the concentration BTC at the operating well. We juxtapose Monte Carlo based numerical results associated with two models: (a) a recently proposed Generalized Sub-Gaussian model which allows capturing non-Gaussian statistical scaling features of RSFs such as hydraulic conductivity, and (b) the commonly used Gaussian field approximation. Our novel results include an appraisal of the coupled effect of (a) the model employed to depict the random spatial variability of K and (b) transient flow regime, as induced by a temporally varying pumping schedule, on the concentration BTC at the operating well. We systematically quantify the sensitivity of the uncertainty in the contaminant BTC to the RSF model adopted for K (non-Gaussian or Gaussian) in the presence of diverse well pumping schedules. Results contribute to

  12. Production optimization of sucker rod pumping wells producing viscous oil in Boscan field, Venezuela

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guirados, C.; Sandoval, J.; Rivas, O.

    1995-12-31

    Boscan field is located in the western coast of Maracaibo lake and is operated by Maraven S.A., affiliate of Petroleos de Venezuela S.A. It has 315 active wells, 252 of which are produced with sucker rod pumping. Other artificial lift methods currently applied in this field are hydraulic (piston) pumping (39 wells) and ESP (24 wells). This paper presents the results of the production optimization of two sucker rod pumping wells of Boscan field producing viscous oil. This optimization has been possible due to the development of a new production scheme and the application of system analysis in completion design.more » The new production scheme involves the utilization of a subsurface stuffing box assembly and a slotted housing, both designed and patented by Intevep S.A., affiliate of Petroleos de Venezuela S.A. The completion design method and software used in the optimization study were also developed by Intevep S.A. The new production scheme and design method proved to be effective in preventing the causes of the above mentioned problems, allowing the increase of oil production under better operating conditions.« less

  13. Simulation of the effects of seasonally varying pumping on intraborehole flow and the vulnerability of public-supply wells to contamination

    USGS Publications Warehouse

    Yager, Richard M.; Heywood, Charles E.

    2014-01-01

    Public-supply wells with long screens in alluvial aquifers can produce waters of differing quality from different depths. Seasonal changes in quality are linked to seasonal changes in pumping rates that influence the distribution of flow into the well screens under pumping conditions and the magnitude and direction of intraborehole flow within the wells under ambient conditions. Groundwater flow and transport simulations with MODFLOW and MT3DMS were developed to quantify the effects of changes in average seasonal pumping rates on intraborehole flow and water quality at two long-screened, public-supply wells, in Albuquerque, New Mexico and Modesto, California, where widespread pumping has altered groundwater flow patterns. Simulation results indicate that both wells produce water requiring additional treatment to maintain potable quality in winter when groundwater withdrawals are reduced because less water is derived from parts of the aquifer that contain water requiring less treatment. Simulation results indicate that the water quality at both wells could be improved by increasing average winter-pumping rates to induce more lateral flow from parts of the aquifer that contain better quality water. Arsenic-bearing water produced by the Albuquerque well could be reduced from 55% to 45% by doubling average winter-pumping rate, while nitrate- and uranium-bearing water produced by the Modesto well could be reduced from 95% to 65% by nearly tripling the average winter-pumping rate. Higher average winter-pumping rates would also reduce the volume of intraborehole flow within both wells and prevent the exchange of poor quality water between shallow and deep parts of both aquifers.

  14. [The use experience of enteral nutrition pump (Applix Smart)].

    PubMed

    Kobayashi, Kaoru; Shirai, Atsushi; Uryu, Shinichi; Kikuchi, Shiro; Momozono, Shinobu; Shimizu, Haruyuki

    2006-12-01

    Nutritional management by using enteral feeding method of nutrition is required for patients of gastroenterological disease with functional disorder in digestion-absorption, and for cases where the patients have difficulty in taking food orally. There are many cases where enteral nutrition pumps are used for administration of nutritious medicines. Approximately 150 enteral nutrition pumps (including house use and home rental) have currently been utilized at our facility. The department of ME Center takes care of enteral nutrition pumps for maintenance and control. On the other hand, we needed to conduct a study for a new pump in replacing Frenta System IV due to the pump was no longer available. At this presentation, we are introducing a new pump manufactured by Fresenius as a replacement of the Frenta System IV. In the meantime, we would like to report a comparison examination of the pump based on its functionality, performance and user friendliness from the view from a clinical technologist as well.

  15. Analytical solutions of travel time to a pumping well with variable evapotranspiration.

    PubMed

    Chen, Tian-Fei; Wang, Xu-Sheng; Wan, Li; Li, Hailong

    2014-01-01

    Analytical solutions of groundwater travel time to a pumping well in an unconfined aquifer have been developed in previous studies, however, the change in evapotranspiration was not considered. Here, we develop a mathematical model of unconfined flow toward a discharge well with redistribution of groundwater evapotranspiration for travel time analysis. Dependency of groundwater evapotranspiration on the depth to water table is described using a linear formula with an extinction depth. Analytical solutions of groundwater level and travel time are obtained. For a typical hypothetical example, these solutions perfectly agree with the numerical simulation results based on MODFLOW and MODPATH. As indicated in a dimensionless framework, a lumped parameter which is proportional to the pumping rate controls the distributions of groundwater evapotranspiration rate and the travel time along the radial direction. © 2013, National Ground Water Association.

  16. Analysis of pumping tests of partially penetrating wells in an unconfined aquifer using inverse numerical optimization

    NASA Astrophysics Data System (ADS)

    Hvilshøj, S.; Jensen, K. H.; Barlebo, H. C.; Madsen, B.

    1999-08-01

    Inverse numerical modeling was applied to analyze pumping tests of partially penetrating wells carried out in three wells established in an unconfined aquifer in Vejen, Denmark, where extensive field investigations had previously been carried out, including tracer tests, mini-slug tests, and other hydraulic tests. Drawdown data from multiple piezometers located at various horizontal and vertical distances from the pumping well were included in the optimization. Horizontal and vertical hydraulic conductivities, specific storage, and specific yield were estimated, assuming that the aquifer was either a homogeneous system with vertical anisotropy or composed of two or three layers of different hydraulic properties. In two out of three cases, a more accurate interpretation was obtained for a multi-layer model defined on the basis of lithostratigraphic information obtained from geological descriptions of sediment samples, gammalogs, and flow-meter tests. Analysis of the pumping tests resulted in values for horizontal hydraulic conductivities that are in good accordance with those obtained from slug tests and mini-slug tests. Besides the horizontal hydraulic conductivity, it is possible to determine the vertical hydraulic conductivity, specific yield, and specific storage based on a pumping test of a partially penetrating well. The study demonstrates that pumping tests of partially penetrating wells can be analyzed using inverse numerical models. The model used in the study was a finite-element flow model combined with a non-linear regression model. Such a model can accommodate more geological information and complex boundary conditions, and the parameter-estimation procedure can be formalized to obtain optimum estimates of hydraulic parameters and their standard deviations.

  17. In-well pumped mid-infrared PbTe/CdTe quantum well vertical external cavity surface emitting lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khiar, A., E-mail: amir.khiar@jku.at; Witzan, M.; Hochreiner, A.

    2014-06-09

    Optical in-well pumped mid-infrared vertical external cavity surface emitting lasers based on PbTe quantum wells embedded in CdTe barriers are realized. In contrast to the usual ternary barrier materials of lead salt lasers such as PbEuTe of PbSrTe, the combination of narrow-gap PbTe with wide-gap CdTe offers an extremely large carrier confinement, preventing charge carrier leakage from the quantum wells. In addition, optical in-well pumping can be achieved with cost effective and readily available near infrared lasers. Free carrier absorption, which is a strong loss mechanism in the mid-infrared, is strongly reduced due to the insulating property of CdTe. Lasingmore » is observed from 85 K to 300 K covering a wavelength range of 3.3–4.2 μm. The best laser performance is achieved for quantum well thicknesses of 20 nm. At low temperature, the threshold power is around 100 mW{sub P} and the output power more than 700 mW{sub P}. The significance of various charge carrier loss mechanisms are analyzed by modeling the device performance. Although Auger losses are quite low in IV–VI semiconductors, an Auger coefficient of C{sub A} = 3.5 × 10{sup −27} cm{sup 6} s{sup −1} was estimated for the laser structure, which is attributed to the large conduction band offset.« less

  18. Hand-Portable Gradient Capillary Liquid Chromatography Pumping System.

    PubMed

    Sharma, Sonika; Plistil, Alex; Barnett, Hal E; Tolley, H Dennis; Farnsworth, Paul B; Stearns, Stanley D; Lee, Milton L

    2015-10-20

    In this work, a novel splitless nanoflow gradient generator integrated with a stop-flow injector was developed and evaluated using an on-column UV-absorption detector. The gradient pumping system consisted of two nanoflow pumps controlled by micro stepper motors, a mixer connected to a serpentine tube, and a high-pressure valve. The gradient system weighed only 4 kg (9 lbs) and could generate up to 55 MPa (8000 psi) pressure. The system could operate using a 24 V DC battery and required 1.2 A for operation. The total volume capacity of the pump was 74 μL, and a sample volume of 60 nL could be injected. The system provided accurate nanoflow rates as low as 10 nL/min without employing a splitter, making it ideal for capillary column use. The gradient dwell volume was calculated to be 1.3 μL, which created a delay of approximately 4 min with a typical flow rate of 350 nL/min. Gradient performance was evaluated for gradient step accuracy, and excellent reproducibility was obtained in day-to-day experiments (RSD < 1.2%, n = 4). Linear gradient reproducibility was tested by separating a three-component pesticide mixture on a poly(ethylene glycol) diacrylate (PEGDA) monolithic column. The retention time reproducibility was very good in run-to-run experiments (RSD < 1.42%, n = 4). Finally, excellent separation of five phenols was demonstrated using the nanoflow gradient system.

  19. Mechanical Clogging Processes in Unconsolidated Porous Media Near Pumping Wells

    NASA Astrophysics Data System (ADS)

    de Zwart, B.; Schotting, R.; Hassanizadeh, M.

    2003-12-01

    In the Netherlands water supply companies produce over more than one billion cubic meters of drinking water every year. About 2500 water wells are used to pump up the groundwater from aquifers in the Dutch subsurface. More than 50% of these wells will encounter a number of technical problems during their lifetime. The main problem is the decrease in capacity due to well clogging. Clogging shows up after a number of operation years and results in extra, expensive cleaning operations and in early replacement of the pumping wells. This problem has been acknowledged by other industries, for example the metal, petroleum, beer industry and underground storage projects. Well clogging is the result of a number of interacting mechanisms creating a complex problem in the subsurface. In most clogging cases mechanical mechanisms are involved. A large number of studies have been performed to comprehend these processes. Investigations on mechanical processes are focused on transport of small particles through pores and deposition of particles due to physical or physical-chemical processes. After a period of deposition the particles plug the pores and decrease the permeability of the medium. Particle deposition in porous media is usually modelled using filtration theory. In order to get the dynamics of clogging this theory is not sufficient. The porous media is continuously altered due to deposition and mobilization. Therefore the capture characteristics will also continuously change and deposition rates will change in time. A new formula is derived to describe (re)mobilization of particles and allow changing deposition rates. This approach incorporates detachment and reattachment of deposited particles. This work also includes derivation of the filtration theory in radial coordinates. A comparison between the radial filtration theory and the new formula will be shown.

  20. A Shocking New Pump

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Hydro Dynamics, Inc. received a technical helping hand from NASA that made their Hydrosonic Pump (HPump) a reality. Marshall engineers resolved a bearing problem in the rotor of the pump and recommended new bearings, housings and mounting hardware as a solution. The resulting HPump is able to heat liquids with greater energy efficiency using shock waves to generate heat.

  1. 46 CFR 182.520 - Bilge pumps.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Highly resistant to salt water, petroleum oil, heat, and vibration. (g) If a fixed hand pump is used to... 46 Shipping 7 2010-10-01 2010-10-01 false Bilge pumps. 182.520 Section 182.520 Shipping COAST...) MACHINERY INSTALLATION Bilge and Ballast Systems § 182.520 Bilge pumps. (a) A vessel must be provided with...

  2. 18. Electrically driven pumps in Armory Street Pump House. Pumps ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Electrically driven pumps in Armory Street Pump House. Pumps in background formerly drew water from the clear well. They went out of service when use of the beds was discontinued. Pumps in the foreground provide high pressure water to Hamden. - Lake Whitney Water Filtration Plant, Armory Street Pumphouse, North side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  3. Theoretical and experimental analysis of a multiphase screw pump, handling gas-liquid mixtures with very high gas volume fractions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raebiger, K.; Faculty of Advanced Technology, University of Glamorgan, Pontypridd, Wales; Maksoud, T.M.A.

    In the investigation of the pumping behaviour of multiphase screw pumps, handling gas-liquid mixtures with very high gas volume fractions, theoretical and experimental analyses were performed. A new theoretical screw pump model was developed, which calculates the time-dependent conditions inside the several chambers of a screw pump as well as the exchange of mass and energy between these chambers. By means of the performed experimental analysis, the screw pump model was verified, especially at very high gas volume fractions from 90% to 99%. The experiments, which were conducted with the reference fluids water and air, can be divided mainly intomore » the determination of the steady state pumping behaviour on the one hand and into the analysis of selected transient operating conditions on the other hand, whereas the visualisation of the leakage flows through the circumferential gaps was rounded off the experimental analysis. (author)« less

  4. 46 CFR 105.35-5 - Fire pumps.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 105.35-5 Section 105.35-5 Shipping COAST... VESSELS DISPENSING PETROLEUM PRODUCTS Fire Extinguishing Equipment § 105.35-5 Fire pumps. (a) All vessels shall be provided with a hand operated portable fire pump having a capacity of at least 5 gallons per...

  5. ADM. Water well pump houses (TAN612 and TAN613). Plans, elevations, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ADM. Water well pump houses (TAN-612 and TAN-613). Plans, elevations, floor and other details. Ralph M. Parsons 902-2-ANP-612-613-A S & P 82. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0612-00-693-106743 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  6. Two-phase flow correlations as applied to pumping well testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kabir, C.S.; Hasan, A.R.

    1994-06-01

    In a pumping-well buildup test, computation of bottom-hole pressure (BHP) and flow rate (BHF) requires the use of a two-phase flow correlation for estimating the gas void-fraction or holdup along the pipe length and shut-in time. Various correlations are available to perform this task. The purpose of this work is to review these two-phase correlations and to provide an objective evaluation. This analysis is necessitated by the fact that considerable differences in BHP and BHF may occur -- depending upon the correlation used -- in wells with long pumping liquid columns or those that have high gas/liquid ratio production. Consequently,more » a potential exists for obtaining different reservoir parameters from transient interpretation. Using laboratory data for two-phase flow in annular geometry, relative strengths of these correlations are explored. The authors' own data and those of others (a total of 114 points) are used in this comparative study. For static liquid columns, the correlations of Hasan-Kabir, Gilbert, and Podio et al. provide acceptable agreement with experimental data, exceptions being the Godbey-Dimon and Schmidt et al. correlations. In contrast, for the moving liquid column scenario, as in a buildup test, the Hasan-Kabir model provides the best agreement with the data set used in this work. A basis for smoothing the bubbly/slug transition boundary is given for the Hasan-Kabir method, together with a field example.« less

  7. Effects of Pumping on Ground-Water Flow Near Water-Supply Wells in the Lower Potomac-Raritan-Magothy Aquifer, Pennsauken Township, Camden County, New Jersey

    USGS Publications Warehouse

    Walker, Richard L.

    2001-01-01

    Since the 1970's, hexavalent chromium has been detected in concentrations as great as 1.0 milligram per liter in wells at the Puchack well field operated by the Camden City Department of Utilities, Water Division (Water Department), forcing the Water Department to progressively remove five of its six wells from service between 1975 and 1988. The wells in the Puchack well field range in depth from 140 to 220 feet and are screened in the Lower Potomac-Raritan-Magothy aquifer. The Water Department has continued to pump Puchack Well 1 to maintain a hydraulic gradient toward the well field in an attempt to limit contaminant migration. In late 1997, concerns about treating the water withdrawn from Puchack Well 1 led water managers to consider temporarily discontinuing the pumping. In the spring of 1998, the U.S. Geological Survey (USGS), in cooperation with the New Jersey Department of Environmental Protection, began a preliminary assessment of the potential effects of temporarily removing Puchack Well 1 from service. Water levels in the Lower Potomac-Raritan-Magothy aquifer were measured during both pumping and nonpumping conditions to determine the direction and velocity of ground-water flow and the results were compared. Data collected in late March and early April 1998 indicate the presence of a ground-water divide between the Puchack well field and the Morris and Delair well fields when Puchack Well 1 was being pumped. A similar divide also was present when the well was not being pumped. The position and persistence of this divide limits the probability that contaminants in the vicinity of the Puchack well field will reach the Delair and Morris well fields during either pumping condition. Another divide southeast of Puchack Well 1 while the well was being pumped was no longer evident when the pumping was stopped and water levels had recovered. Under non-pumping conditions, ground water between Puchack Well 1 and this divide could begin to migrate toward other large

  8. Field experiment and numerical simulation of coupling non-Darcy flow caused by curtain and pumping well in foundation pit dewatering

    NASA Astrophysics Data System (ADS)

    Wang, Jianxiu; Liu, Xiaotian; Wu, Yuanbin; Liu, Shaoli; Wu, Lingao; Lou, Rongxiang; Lu, Jiansheng; Yin, Yao

    2017-06-01

    High-velocity non-Darcy flow produced larger drawdown than Darcy flow under the same pumping rate. When the non-Darcy flow caused by curtain met non-Darcy flow caused by pumping wells, superposition and amplification effect occurred in the coupling area, the non-Darcy flow was defined as coupling non-Darcy flow. The coupling non-Darcy flow can be produced and controlled using different combination of curtain and pumping wells in foundation pit dewatering to obtain the maximum drawdown using the minimum pumping rate. The Qianjiang Century City Station foundation pit of Hangzhou subway, China, was selected as background. Field experiments were performed to observe the coupling non-Darcy flow in round gravel. A generalized conceptual model was established to study the coupling effect under different combination of curtain and pumping wells. Numerical simulations of the coupling non-Darcy flow in foundation pit dewatering were carried out based on the Forchheimer equation. The non-Darcy flow area and flow velocity were influenced by the coupling effect. Short filter tube, large pumping rate, small horizontal distance between filter tube and diaphragm wall, and small vertical distance between the filter tube and confined aquifer roof effectively strengthened the coupling effect and obtained a large drawdown. The pumping wells installed close to a curtain was an intentional choice designed to create coupling non-Darcy flow and obtain the maximize drawdown. It can be used in the dewatering of a long and narrow foundation pit, such as a subway foundation pit.

  9. Constant-head pumping test of a multiaquifer well to determine characteristics of individual aquifers

    USGS Publications Warehouse

    Bennett, Gordon D.; Patten, E.P.

    1962-01-01

    This report describes the theory and field procedures for determining the transmissibility and storage coefficients and the original hydrostatic head of each aquifer penetrated by a multiaquifer well. The procedure involves pumping the well in such a manner that the drawdown of water level is constant while the discharges of the different aquifers are measured by means of borehole flowmeters. The theory is developed by analogy to the heat-flow problem solved by Smith. The internal discharge between aquifers after the well is completed is analyzed as the first step. Pumping at constant, drawdown constitutes the second step. Transmissibility and storage coefficients are determined by a method described by Jacob and Lohman, after the original internal discharge to or from the aquifer has been compensated for in the calculations. The original hydrostatic head of each aquifer is then determined by resubstituting the transmissibility and storage coefficients into the first step of the analysis. The method was tested on a well in Chester County, Pa., but the results were not entirely satisfactory, owing to the lack of sufficiently accurate methods of flow measurement and, probably, to the effects of entrance losses in the well. The determinations of the transmissibility coefficient and static head can be accepted as having order-of-magnitude significance, but the determinations of the storage coefficient, which is highly sensitive to experimental error, must be rejected. It is felt that better results may be achieved in the future, as more reliable devices for metering the flow become available and as more is learned concerning the nature of entrance losses. If accurate data can be obtained, recently developed techniques of digital or analog computation may permit determination of the response of each aquifer in the well to any form of pumping.

  10. Health promotion, wellness, and prevention in hand therapy: A survey study.

    PubMed

    Lucado, Ann M; Taylor, David W; Wendland, Deborah M; Connors, Brian

    Descriptive study. Noncommunicable diseases including diabetes and cardiovascular disease are associated with increased complications and cost of health care. To describe beliefs and extent to which hand therapists include health promotion, wellness, and prevention (HPWP) in practice and to elucidate barriers to the incorporation of HPWP. A 38-question survey evaluating hand therapists' beliefs, practice of HPWP, and barriers was sent to American Society of Hand Therapists members. About 270 American Society of Hand Therapists members participated. Respondents believed they had a role in HPWP, including occupational (95%), physical (92%), emotional (87%), and psychological (84%) factors and instrumental activities of daily living management (98%). Physical activity is most frequently addressed (42%), whereas other health behaviors are rarely addressed. Time, patient interest, and resources were among identified barriers. The importance of health promotion and disease prevention practice is being recognized as critical to successful health outcomes. The study results suggest the need to develop HPWP educational programming for hand therapists and the need to consider expansion of understanding of HPWP initiatives and subsequent benefits to patients. 5. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  11. Feasibility: An important but neglected issue in patient hand hygiene.

    PubMed

    Knighton, Shanina C; McDowell, Cherese; Rai, Herleen; Higgins, Patricia; Burant, Christopher; Donskey, Curtis J

    2017-06-01

    Patient hand hygiene may be a useful strategy to prevent acquisition of pathogens and to reduce the risk for transmission by colonized patients. Several studies demonstrate that patients and long-term-care facility (LTCF) residents may have difficulty using hand hygiene products that are provided; however, none of them measure feasibility for patients to use different hand hygiene products. A convenience sample of 42 hospitalized patients and 46 LTCF residents was assessed for their ability to use 3 hand sanitizer products (8-oz pushdown pump bottle, 2-oz pocket-sized bottle with a reclosable lid, and alcohol-impregnated hand wipes). The time (seconds) required for accessing each product was compared among acute-care patients and LTCF residents. Participants provided feedback on which product they preferred and found easiest to use. Of 88 participants, 86 (97.7%) preferred the pushdown pump, 2 (2.3%) preferred the bottle with the reclosable lid, and none preferred the hand wipes. For both hospitalized patients and LTCF residents, the average time required to access the pushdown pump was significantly less than the time required to access the other products (pushdown pump, 0.45 seconds; bottle with reclosable lid, 3.86 seconds; and wipes, 5.66 seconds; P < .001). Feasibility and ease of use should be considered in the selection of hand hygiene products for patients and LTCF residents. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  12. The development and testing of a fieldworthy system of improved fluid pumping device and liquid sensor for oil wells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buckman, W.G.

    1991-12-31

    A major expenditure to maintain oil and gas leases is the support of pumpers, those individuals who maintain the pumping systems on wells to achieve optimum production. Many leases are marginal and are in remote areas and this requires considerable driving time for the pumper. The Air Pulse Oil Pump System is designed to be an economical system for the shallow stripper wells. To improve on the economics of this system, we have designed a Remote Oil Field Monitor and Controller to enable us to acquire data from the lease to our central office at anytime and to control themore » pumping activities from the central office by using a personal computer. The advent and economics of low-power microcontrollers have made it feasible to use this type of system for numerous remote control systems. We can also adapt this economical system to monitor and control the production of gas wells and/or pump jacks.« less

  13. A closed form solution for constant flux pumping in a well under partial penetration condition

    NASA Astrophysics Data System (ADS)

    Yang, Shaw-Yang; Yeh, Hund-Der; Chiu, Pin-Yuan

    2006-05-01

    An analytical model for the constant flux pumping test is developed in a radial confined aquifer system with a partially penetrating well. The Laplace domain solution is derived by the application of the Laplace transforms with respect to time and the finite Fourier cosine transforms with respect to the vertical coordinates. A time domain solution is obtained using the inverse Laplace transforms, convolution theorem, and Bromwich integral method. The effect of partial penetration is apparent if the test well is completed with a short screen. An aquifer thickness 100 times larger than the screen length of the well can be considered as infinite. This solution can be used to investigate the effects of screen length and location on the drawdown distribution in a radial confined aquifer system and to produce type curves for the estimation of aquifer parameters with field pumping drawdown data.

  14. Phase Recovery Acceleration of Quantum-Dot Semiconductor Optical Amplifiers by Optical Pumping to Quantum-Well Wetting Layer

    NASA Astrophysics Data System (ADS)

    Kim, Jungho

    2013-11-01

    We theoretically investigate the phase recovery acceleration of quantum-dot (QD) semiconductor optical amplifiers (SOAs) by means of the optical pump injection to the quantum-well (QW) wetting layer (WL). We compare the ultrafast gain and phase recovery responses of QD SOAs in either the electrical or the optical pumping scheme by numerically solving 1088 coupled rate equations. The ultrafast gain recovery responses on the order of sub-picosecond are nearly the same for the two pumping schemes. The ultrafast phase recovery is not significantly accelerated by increasing the electrical current density, but greatly improved by increasing the optical pumping power to the QW WL. Because the phase recovery time of QD SOAs with the optical pumping scheme can be reduced down to several picoseconds, the complete phase recovery can be achieved when consecutive pulse signals with a repetition rate of 100 GHz is injected.

  15. Modeling the effects of pumping wells in spring management: The case of Scirca spring (central Apennines, Italy)

    NASA Astrophysics Data System (ADS)

    Dragoni, W.; Mottola, A.; Cambi, C.

    2013-06-01

    One of the techniques used to increase the water yield of springs during dry seasons and droughts is drilling wells close to them. Where there is a low-hydraulic conductivity boundary close to a spring (the case considered here), this technique implies low well efficiency, high drawdown, and high cost of withdrawals. In addition, a set of pumping wells close to a spring can cause both it and the stream originating from it to dry up - a situation which is not always acceptable from an environmental point of view. In order to study better management strategies, this paper presents a finite difference model of the Scirca spring (Umbria - Marche Apennines, Italy), which originates from a limestone massif in which some formations are karstified. The model, built with Modflow using the equivalent porous media (EPM) approach, simulated the effects of pumping wells at various distances from the spring. Hydraulic Conductivity and Storativity were calibrated and validated on discharge data during recession, when recharge is nil. "Inverse modeling" was then used to estimate the daily recharge of the hydro-geological system of the Scirca spring for a period of several years. Lastly, the efficiency of various management schemes was evaluated by simulating the reaction of the spring, in terms of discharge, to a series of pumping scenarios, all guaranteeing a certain imposed withdrawal during summer, much larger than the natural spring discharge, given by spring discharge and well drawdown. The wells were located between 2850 and 100 m from the spring, the pumping time-span was set at 90 days, and pumping rates of 60, 90 and 120 l/s were applied. Results show that the maximum discharge at which spring drainage is avoided and that minimum vital flow is guaranteed is 90 l/s. The higher water volumes extracted during summer (dry season) are balanced by a lowering of the maximum natural discharges in winter and spring (recharge seasons). Simulations indicate that, by drilling pumping

  16. Solute concentration at a well in non-Gaussian aquifers under constant and time-varying pumping schedule

    NASA Astrophysics Data System (ADS)

    Libera, Arianna; de Barros, Felipe P. J.; Riva, Monica; Guadagnini, Alberto

    2017-10-01

    Our study is keyed to the analysis of the interplay between engineering factors (i.e., transient pumping rates versus less realistic but commonly analyzed uniform extraction rates) and the heterogeneous structure of the aquifer (as expressed by the probability distribution characterizing transmissivity) on contaminant transport. We explore the joint influence of diverse (a) groundwater pumping schedules (constant and variable in time) and (b) representations of the stochastic heterogeneous transmissivity (T) field on temporal histories of solute concentrations observed at an extraction well. The stochastic nature of T is rendered by modeling its natural logarithm, Y = ln T, through a typical Gaussian representation and the recently introduced Generalized sub-Gaussian (GSG) model. The latter has the unique property to embed scale-dependent non-Gaussian features of the main statistics of Y and its (spatial) increments, which have been documented in a variety of studies. We rely on numerical Monte Carlo simulations and compute the temporal evolution at the well of low order moments of the solute concentration (C), as well as statistics of the peak concentration (Cp), identified as the environmental performance metric of interest in this study. We show that the pumping schedule strongly affects the pattern of the temporal evolution of the first two statistical moments of C, regardless the nature (Gaussian or non-Gaussian) of the underlying Y field, whereas the latter quantitatively influences their magnitude. Our results show that uncertainty associated with C and Cp estimates is larger when operating under a transient extraction scheme than under the action of a uniform withdrawal schedule. The probability density function (PDF) of Cp displays a long positive tail in the presence of time-varying pumping schedule. All these aspects are magnified in the presence of non-Gaussian Y fields. Additionally, the PDF of Cp displays a bimodal shape for all types of pumping

  17. 46 CFR 56.50-55 - Bilge pumps.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Type of vessel Waters navigated Power pumps (1) Hand pumps Sailing Ocean and coastwise Two (2) Manned... Vessels Vessel length, in feet Passenger vessels 1 International voyages 3 Ocean, coast-wise and Great Lakes All other waters Dry-cargo vessels 2 Ocean, coast-wise and Great Lakes All waters Tankvessels All...

  18. 46 CFR 56.50-55 - Bilge pumps.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Type of vessel Waters navigated Power pumps (1) Hand pumps Sailing Ocean and coastwise Two (2) Manned... Vessels Vessel length, in feet Passenger vessels 1 International voyages 3 Ocean, coast-wise and Great Lakes All other waters Dry-cargo vessels 2 Ocean, coast-wise and Great Lakes All waters Tankvessels All...

  19. 46 CFR 56.50-55 - Bilge pumps.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Type of vessel Waters navigated Power pumps (1) Hand pumps Sailing Ocean and coastwise Two (2) Manned... Vessels Vessel length, in feet Passenger vessels 1 International voyages 3 Ocean, coast-wise and Great Lakes All other waters Dry-cargo vessels 2 Ocean, coast-wise and Great Lakes All waters Tankvessels All...

  20. Analysis of complex pumping interactions during an aquifer test conducted at a well field in the coastal plain near Augusta, Georgia, October 2009

    USGS Publications Warehouse

    Gonthier, Gerald J.

    2009-01-01

    A 24-hour aquifer test was conducted in Well Field 2 near Augusta, Georgia, October 21–22, 2009, to characterize the hydraulic properties of the Midville aquifer system. The selected well was pumped at a rate of 684 gallons per minute. At the initiation of aquifer-test pumping, water levels in each of eight wells monitored for the test were still recovering from the well-field production. Because water levels had not stabilized, data analyses were needed to account for the ongoing recovery. Hydraulic properties of the Midville aquifer system were estimated by an approach based on the Theis model and superposition. The Midville aquifer system was modeled as a Theis aquifer. The principle of superposition was used to sum the effects of multiple pumping and recovery events from a single pumped well and to sum the effects of all pumped wells as the estimated total drawdown at a monitored well. Simulated drawdown at each monitored well was determined by using a spreadsheet (SUMTheis) function of aquifer transmissivity and storativity. Simulated drawdown values were transformed into simulated water levels, accounting for longterm water-level trends. The transmissivity and storativity values that were used to calibrate the simulated water levels to measured water levels (roughly 4,000 square feet per day and 2E-04, respectively) provide estimates of the transmissivity and storativity of the Midville aquifer system in the vicinity of Well Field 2. The approach used in this study can be applied to similar well-field tests in which incomplete drawdown recovery or other known pumping is evident.

  1. Transient effects on groundwater chemical compositions from pumping of supply wells at the Nevada National Security Site, 1951-2008

    USGS Publications Warehouse

    Paces, James B.; Elliott, Peggy E.; Fenelon, Joseph M.; Laczniak, Randell J.; Moreo, Michael T.

    2012-01-01

    Nuclear testing and support activities at the Nevada National Security Site have required large amounts of water for construction, public consumption, drilling, fire protection, hydraulic and nuclear testing, and dust control. To supply this demand, approximately 20,000 million gallons of water have been pumped from 23 wells completed in 19 boreholes located across the Nevada National Security Site starting as early as the 1950s. As a consequence of more or less continuous pumping from many of these wells for periods as long as 58 years, transient groundwater flow conditions have been created in the aquifers that supplied the water. To evaluate whether long-term pumping caused changes in water compositions over time, available chemical analyses of water samples from these 19 boreholes were compiled, screened, and evaluated for variability including statistically significant temporal trends that can be compared to records of groundwater pumping. Data used in this report have been extracted from a large database (Geochem08, revision 3.0, released in September 2008) containing geochemical and isotopic information created and maintained by primary contractors to the U.S. Department of Energy, National Nuclear Security Administration, Nevada Site Office. Data extracted from this source were compiled for the entire period of record, converted to uniform reporting units, and screened to eliminate analyses of poor or unknown quality, as well as clearly spurious values. The resulting data are included in accompanying spreadsheets that give values for (1) pH and specific conductance, (2) major ion concentrations, (3) trace element concentrations and environmental isotope ratios, and (4) mean, median, and variance estimates for major ion concentrations. The resulting data vary widely in quality and time-series density. An effort has been made to establish reasonable ranges of analytical uncertainty expected for each analyte and eliminate analyses that are obvious outliers

  2. 46 CFR 56.50-55 - Bilge pumps.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Type of vessel Waters navigated Power pumps (1) Hand pumps Sailing Ocean and coastwise Two (2) Manned... Vessels Vessel length, in feet Passenger vessels 1 International voyages 3 Ocean, coast-wise and Great Lakes All other waters Dry-cargo vessels 2 Ocean, coast-wise and Great Lakes All waters Tank vessels All...

  3. 7 CFR 58.219 - High pressure pumps and lines.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false High pressure pumps and lines. 58.219 Section 58.219....219 High pressure pumps and lines. High pressure lines may be cleaned-in-place and shall be of such construction that dead ends, valves and the high pressure pumps can be disassembled for hand cleaning. The high...

  4. Predicted hydrologic effects of pumping from the Lichterman Well Field in the Memphis Area, Tennessee

    USGS Publications Warehouse

    Nyman, Dale J.

    1965-01-01

    The Lichterman well field is scheduled to go into operation early in 1965 to supplement the municipal water-supply system for the city of Memphis, Tenn. Although the initial rate of withdrawal from the well field will be about 8 mgd (million gallons per day), the ultimate design capacity of the field is 20 mgd. A study of sand samples, drillers' logs, and geophysical logs collected during preliminary test drilling at the site for the Lichterman well field was used as a basis for defining three zones of sand favorable for the construction of high-capacity (1,000 gallons per minute or more) water wells. The three zones occur in the '500-foot' sand and are here designated (in descending order) as zone A, zone B, and zone C. The depth to the top of these zones below land surface has the following ranges: zone A, 125 to 225 feet; zone B, 200 to 350 feet; and zone C, 700 to 775 feet. Zones A and B range from 0 to 100 feet in thickness, and zone C ranges from 10 to 100 feet in thickness. Within the well field proper these zones are expected to react to the stress of pumping as separate hydrologic units, but outside the well field the three zones are expected to react as a single hydrologic unit. The '500-foot' sand in the Germantown-Collierville area is recharged chiefly by precipitation on the outcrop area of the sand to the east, but the evidence indicates that additional recharge is entering the aquifer from the Wolf River. In spite of this additional recharge, water levels in the '500-foot' sand are declining at an average rate of about two-thirds of a foot per year, owing to municipal and industrial pumpage in the Memphis area. However, this decline is not expected to alter the excellent quality of the water in the '500-foot' sand at the site of the Lichterman well field. Pumping in the Lichterman well field will create a cone of depression in the free-water (piezometric) surface of the '500-foot' sand. The decline in water levels will be directly proportional to the

  5. Estimation of the recharge area contributing water to a pumped well in a glacial-drift, river-valley aquifer

    USGS Publications Warehouse

    Morrissey, Daniel J.

    1989-01-01

    The highly permeable, unconfined, glacial-drift aquifers that occupy most New England river valleys constitute the principal source of drinking water for many of the communities that obtain part or all of their public water supply from ground water. Recent events have shown that these aquifers are highly susceptible to contamination that results from a number of sources, such as seepage from wastewater lagoons, leaking petroleum-product storage tanks, and road salting. To protect the quality of water pumped from supply wells in these aquifers, it is necessary to ensure that potentially harmful contaminants do not enter the ground in the area that contributes water to the well. A high degree of protection can be achieved through the application of appropriate land-use controls within the contributing area. However, the contributing areas for most supply wells are not known. This report describes the factors that affect the size and shape of contributing areas to public supply wells and evaluates several methods that may be used to delineate contributing areas of wells in glacial-drift, river-valley aquifers. Analytical, two-dimensional numerical, and three-dimensional numerical models were used to delineate contributing areas. These methods of analysis were compared by applying them to a hypothetical aquifer having the dimensions and geometry of a typical glacial-drift, river-valley aquifer. In the model analyses, factors that control the size and shape of a contributing area were varied over ranges of values common to glacial-drift aquifers in New England. The controlling factors include the rate of well discharge, rate of recharge to the aquifer from precipitation and from adjacent till and bedrock uplands, distance of a pumping well from a stream or other potential source of induced recharge, degree of hydraulic connection of the aquifer with a stream, horizontal hydraulic conductivity of the aquifer, ratio of horizontal to vertical hydraulic conductivity, and

  6. Fundamental Study of Nuclear Pumped Laser Plasmas.

    DTIC Science & Technology

    1980-12-23

    PUMPED DYE LASER PMT PUMPING/ GAS HAND- LING SYSTEM ANODE SIGNAL TO SCREEN ROOM FIGURE 13 EXPERIMENTAL APPARATUS FROM ANODE OF PMT SCREEN ROOM...and G.A. Zdasiuk, " Laser Induced Collisional and Radiative Energy Transfer’, Proceedings of Laser Spectroscopy IV, June 1979. W. R. Green, M.D. Wright...AD-A130 988 FUNDAMENTAL STUDY 0F NUCLEAR PUMPED LASER PLASMAS(U) 1/ MIAMI UNIV OXFORD UHDi EPT OF PHYSIS Cs W DOWNES ET AL 23 DEC AS OASGAS 7A C OSAN

  7. Streamflow depletion by wells--Understanding and managing the effects of groundwater pumping on streamflow

    USGS Publications Warehouse

    Barlow, Paul M.; Leake, Stanley A.

    2012-11-02

    Groundwater is an important source of water for many human needs, including public supply, agriculture, and industry. With the development of any natural resource, however, adverse consequences may be associated with its use. One of the primary concerns related to the development of groundwater resources is the effect of groundwater pumping on streamflow. Groundwater and surface-water systems are connected, and groundwater discharge is often a substantial component of the total flow of a stream. Groundwater pumping reduces the amount of groundwater that flows to streams and, in some cases, can draw streamflow into the underlying groundwater system. Streamflow reductions (or depletions) caused by pumping have become an important water-resource management issue because of the negative impacts that reduced flows can have on aquatic ecosystems, the availability of surface water, and the quality and aesthetic value of streams and rivers. Scientific research over the past seven decades has made important contributions to the basic understanding of the processes and factors that affect streamflow depletion by wells. Moreover, advances in methods for simulating groundwater systems with computer models provide powerful tools for estimating the rates, locations, and timing of streamflow depletion in response to groundwater pumping and for evaluating alternative approaches for managing streamflow depletion. The primary objective of this report is to summarize these scientific insights and to describe the various field methods and modeling approaches that can be used to understand and manage streamflow depletion. A secondary objective is to highlight several misconceptions concerning streamflow depletion and to explain why these misconceptions are incorrect.

  8. Solid state control system for oil well bailer pump

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Senghaas, K. A.; Senghaas, P.

    1985-05-14

    A solid state switching controller for use with various types of oil well bailer pumps. Individually programmable steps with lockouts provide multiple mutual exclusivity between various circuit operations. A trickle charge battery system powers the control circuits. A tank overflow float protects against oil spillage. An automatic production rate adjustment circuit is provided which increases cycle time in proportion to the rate of production. The circuit includes a low power voltage detector for disabling the control circuits until the line voltage is acceptable. A three-phase power and control system with an isolation transformer for the controls avoids unreliable ground connections.more » The timers include a dividing circuit with an RC circuit. All power actuated apparatus are actuated by triac switches which are controlled by an opto driver. The bailer brake is pulse actuated for allowing the bailer to sink into crude oil without excess cable looseness.« less

  9. General well function for pumping from a confined, leaky, or unconfined aquifer

    NASA Astrophysics Data System (ADS)

    Perina, Tomas; Lee, Tien-Chang

    2006-02-01

    A general well function for groundwater flow toward an extraction well with non-uniform radial flux along the screen and finite-thickness skin, partially penetrating an unconfined, leaky-boundary flux, or confined aquifer is derived via the Laplace and generalized finite Fourier transforms. The mixed boundary condition at the well face is solved as the discretized Fredholm integral equation. The general well function reduces to a uniform radial flux solution as a special case. In the Laplace domain, the relation between the drawdown in the extraction well and flowrate is linear and the formulations for specified flowrate or specified drawdown pumping are interchangeable. The deviation in drawdown of the uniform from non-uniform radial flux solutions depends on the relative positions of the extraction and observation well screens, aquifer properties, and time of observation. In an unconfined aquifer the maximum deviation occurs during the period of delayed drawdown when the effect of vertical flow is most apparent. The skin and wellbore storage in an observation well are included as model parameters. A separate solution is developed for a fully penetrating well with the radial flux being a continuous function of depth.

  10. Domestic wells have high probability of pumping septic tank leachate

    NASA Astrophysics Data System (ADS)

    Bremer, J. E.; Harter, T.

    2012-08-01

    Onsite wastewater treatment systems are common in rural and semi-rural areas around the world; in the US, about 25-30% of households are served by a septic (onsite) wastewater treatment system, and many property owners also operate their own domestic well nearby. Site-specific conditions and local groundwater flow are often ignored when installing septic systems and wells. In areas with small lots (thus high spatial septic system densities), shallow domestic wells are prone to contamination by septic system leachate. Mass balance approaches have been used to determine a maximum septic system density that would prevent contamination of groundwater resources. In this study, a source area model based on detailed groundwater flow and transport modeling is applied for a stochastic analysis of domestic well contamination by septic leachate. Specifically, we determine the probability that a source area overlaps with a septic system drainfield as a function of aquifer properties, septic system density and drainfield size. We show that high spatial septic system density poses a high probability of pumping septic system leachate. The hydraulic conductivity of the aquifer has a strong influence on the intersection probability. We find that mass balance calculations applied on a regional scale underestimate the contamination risk of individual drinking water wells by septic systems. This is particularly relevant for contaminants released at high concentrations, for substances that experience limited attenuation, and those that are harmful even at low concentrations (e.g., pathogens).

  11. Computer fluid dynamics (CFD) study of a micro annular gear pump

    NASA Astrophysics Data System (ADS)

    Stan, Liviu-Constantin; Cǎlimǎnescu, Ioan

    2016-12-01

    Micro technology makes it possible to design products simply, efficiently and sustainably and at the same time, opens up the creation of new functionalities. The field of application of the micro annular gear pumps lies in analytical instrumentation, mechanical and plant engineering, chemical and pharmaceutical process engineering as well as in new markets like fuel cells or biotechnology, organic electronics or aerospace. The purpose of this paper is to investigate by using the powerful ANSYS 16 CFX module the hydrodynamic behavior of an 8/9 teeth annular gear pump. The solving of solids evolving inside fluids was very cumbersome until the advent of the Ansys immersed solid technology. By deploying this technology for very special topics like the CFD analysis of Micro annular gear pumps, credible and reliable results may be pulled leading thus the way for more in depth studies like geometrical a functional optimization of the existing devices. This paper is a valuable guide for the professionals working in the design field of micro pumps handing them a new and powerful design tool.

  12. Aquifer geochemistry and effects of pumping on ground-water quality at the Green Belt Parkway Well Field, Holbrook, Long Island, New York

    USGS Publications Warehouse

    Brown, Craig J.; Colabufo, Steven; Coates, John D.

    2002-01-01

    Geochemistry, microbiology, and water quality of the Magothy aquifer at a new supply well in Holbrook were studied to help identify factors that contribute to iron-related biofouling of public-supply wells. The organic carbon content of borehole sediments from the screen zone, and the dominant terminal electron-accepting processes (TEAPs), varied by depth. TEAP assays of core sediments indicated that iron reduction, sulfate reduction, and undetermined (possibly oxic) reactions and microbial activity are correlated with organic carbon (lignite) content. The quality of water from this well, therefore, reflects the wide range of aquifer microenvironments at this site.High concentrations of dissolved iron (3.6 to 6.4 micromoles per liter) in water samples from this well indicate that some water is derived from Fe(III)-reducing sediments within the aquifer, but traces of dissolved oxygen indicate inflow of shallow, oxygenated water from shallow units that overlie the local confining units. Water-quality monitoring before and during a 2-day pumping test indicates that continuous pumping from the Magothy aquifer at this site can induce downward flow of shallow, oxygenated water despite the locally confined conditions. Average concentrations of dissolved oxygen are high (5.2 milligrams per liter, or mg/L) in the overlying upper glacial aquifer and at the top of the Magothy aquifer (4.3 mg/L), and low ( < 0.1 mg/L) in the deeper, anaerobic part of the Magothy; average concentrations of phosphate are high (0.4 mg/L) in the upper glacial aquifer and lower (0.008 mg/L) at the top of the Magothy aquifer and in the deeper part of the Magothy (0.013 mg/L). Concentrations of both constituents increased during the 2 days of pumping. The δ34S of sulfate in shallow ground water from observation wells (3.8 to 6.4 per mil) was much heavier than that in the supplywell water (-0.1 per mil) and was used to help identify sources of water entering the supply well. The δ34S of sulfate in a

  13. Direct solar-pumped iodine laser amplifier

    NASA Technical Reports Server (NTRS)

    Han, Kwang S.; Kim, K. H.; Stock, L. V.

    1987-01-01

    The improvement on the collection system of the Tarmarack Solar Simulator beam was attemped. The basic study of evaluating the solid state laser materials for the solar pumping and also the work to construct a kinetic model algorithm for the flashlamp pumped iodine lasers were carried out. It was observed that the collector cone worked better than the lens assembly in order to collect the solar simulator beam and to focus it down to a strong power density. The study on the various laser materials and their lasing characteristics shows that the neodymium and chromium co-doped gadolinium scandium gallium garnet (Nr:Cr:GSGG) may be a strong candidate for the high power solar pumped solid state laser crystal. On the other hand the improved kinetic modeling for the flashlamp pumped iodine laser provides a good agreement between the theoretical model and the experimental data on the laser power output, and predicts the output parameters of a solar pumped iodine laser.

  14. PUMPS

    DOEpatents

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  15. A simulation-based study on different control strategies for variable speed pump in distributed ground source heat pump systems

    DOE PAGES

    Liu, Xiaobing; Zheng, O'Neill; Niu, Fuxin

    2016-01-01

    Most commercial ground source heat pump systems (GSHP) in the United States are in a distributed configuration. These systems circulate water or an anti-freeze solution through multiple heat pump units via a central pumping system, which usually uses variable speed pump(s). Variable speed pumps have potential to significantly reduce pumping energy use; however, the energy savings in reality could be far away from its potential due to improper pumping system design and controls. In this paper, a simplified hydronic pumping system was simulated with the dynamic Modelica models to evaluate three different pumping control strategies. This includes two conventional controlmore » strategies, which are to maintain a constant differential pressure across either the supply and return mains, or at the most hydraulically remote heat pump; and an innovative control strategy, which adjusts system flow rate based on the demand of each heat pump. The simulation results indicate that a significant overflow occurs at part load conditions when the variable speed pump is controlled to main a constant differential pressure across the supply and return mains of the piping system. On the other hand, an underflow occurs at part load conditions when the variable speed pump is controlled to maintain a constant differential pressure across the furthest heat pump. The flow-demand-based control can provide needed flow rate to each heat pump at any given time, and with less pumping energy use than the two conventional controls. Finally, a typical distributed GSHP system was studied to evaluate the energy saving potential of applying the flow-demand-based pumping control strategy. This case study shows that the annual pumping energy consumption can be reduced by 62% using the flow-demand-based control compared with that using the conventional pressure-based control to maintain a constant differential pressure a cross the supply and return mains.« less

  16. 12. VIEW OF PUMPS NO. 6, 8, AND 7 (L ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. VIEW OF PUMPS NO. 6, 8, AND 7 (L TO R) WITH THEIR CANVAS COVERS, LOOKING NORTHEAST. NOTE CONCRETE CONSTRUCTION. THE FOUR LIGHT WINDOWS AND THE STEEL EAM FOR THE 10-TON HAND OPERATED TRAVELING CRANE. - Wyoming Valley Flood Control System, Woodward Pumping Station, East of Toby Creek crossing by Erie-Lackawanna Railroad, Edwardsville, Luzerne County, PA

  17. The development and testing of a fieldworthy system of improved fluid pumping device and liquid sensor for oil wells. Fourth quarter technical progress report, 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buckman, W.G.

    1991-12-31

    A major expenditure to maintain oil and gas leases is the support of pumpers, those individuals who maintain the pumping systems on wells to achieve optimum production. Many leases are marginal and are in remote areas and this requires considerable driving time for the pumper. The Air Pulse Oil Pump System is designed to be an economical system for the shallow stripper wells. To improve on the economics of this system, we have designed a Remote Oil Field Monitor and Controller to enable us to acquire data from the lease to our central office at anytime and to control themore » pumping activities from the central office by using a personal computer. The advent and economics of low-power microcontrollers have made it feasible to use this type of system for numerous remote control systems. We can also adapt this economical system to monitor and control the production of gas wells and/or pump jacks.« less

  18. A 980 nm pseudomorphic single quantum well laser for pumping erbium-doped optical fiber amplifiers

    NASA Technical Reports Server (NTRS)

    Larsson, A.; Forouhar, S.; Cody, J.; Lang, R. J.; Andrekson, P. A.

    1990-01-01

    The authors have fabricated ridge waveguide pseudomorphic InGaAs/GaAs/AlGaAs GRIN-SCH SQW (graded-index separate-confinement-heterostructure single-quantum-well) lasers, emitting at 980 nm, with a maximum output power of 240 mW from one facet and a 22 percent coupling efficiency into a 1.55-micron single-mode optical fiber. These lasers satisfy the requirements on efficient and compact pump sources for Er3+-doped fiber amplifiers.

  19. Mathematical Modeling of Loop Heat Pipes with Multiple Capillary Pumps and Multiple Condensers. Part 1; Stead State Stimulations

    NASA Technical Reports Server (NTRS)

    Hoang, Triem T.; OConnell, Tamara; Ku, Jentung

    2004-01-01

    Loop Heat Pipes (LHPs) have proven themselves as reliable and robust heat transport devices for spacecraft thermal control systems. So far, the LHPs in earth-orbit satellites perform very well as expected. Conventional LHPs usually consist of a single capillary pump for heat acquisition and a single condenser for heat rejection. Multiple pump/multiple condenser LHPs have shown to function very well in ground testing. Nevertheless, the test results of a dual pump/condenser LHP also revealed that the dual LHP behaved in a complicated manner due to the interaction between the pumps and condensers. Thus it is redundant to say that more research is needed before they are ready for 0-g deployment. One research area that perhaps compels immediate attention is the analytical modeling of LHPs, particularly the transient phenomena. Modeling a single pump/single condenser LHP is difficult enough. Only a handful of computer codes are available for both steady state and transient simulations of conventional LHPs. No previous effort was made to develop an analytical model (or even a complete theory) to predict the operational behavior of the multiple pump/multiple condenser LHP systems. The current research project offered a basic theory of the multiple pump/multiple condenser LHP operation. From it, a computer code was developed to predict the LHP saturation temperature in accordance with the system operating and environmental conditions.

  20. Analysis of vertical flow during ambient and pumped conditions in four monitoring wells at the Pantex Plant, Carson County, Texas, July-September 2008

    USGS Publications Warehouse

    Stanton, Gregory P.; Thomas, Jonathan V.; Stoval, Jeffery

    2009-01-01

    Logs collected in monitoring well PTX06–1068 during ambient conditions indicate a static environment with no flow. During pumping there was upward vertical flow at rates ranging from 0.4 to 4.8 gallons per minute. During pumping, a gradual trend of more positive flowmeter values (upward flow) with distance up the well was observed. Estimated total transmissivity for four production zones identified from Flow–B numerical model results taken together was calculated to be about 200 feet squared per day.

  1. Benefits of the rotary diaphragm pump.

    PubMed

    Borstell, D

    2005-03-01

    The huge variety of applications in the medical field represents a challenge for the design of miniature pumps. There are well-known designs such as piston pumps, eccenter diaphragm pumps and peristaltic pumps. There are lesser-known types such as the rotary diaphragm pump, the subject of this article. Its design features, variants, and advantages and disadvantages are examined.

  2. Community wells to mitigate the arsenic crisis in Bangladesh.

    PubMed Central

    van Geen, Alexander; Ahmed, K. M.; Seddique, A. A.; Shamsudduha, M.

    2003-01-01

    OBJECTIVE: To monitor the effectiveness of deep community wells in reducing exposure to elevated levels of arsenic in groundwater pumped from shallower aquifers. METHODS: Six community wells ranging in depth from 60 m to 140 m were installed in villages where very few of the wells already present produced safe water. By means of flow meters and interviews with villagers carrying water from the community wells, a study was made of the extent to which these were used during one year. The results were compared with household and well data obtained during a previous survey in the same area. FINDINGS: The mean arsenic concentration in water pumped from wells already in use in the villages where the community wells, were installed was 180 +/- 140 micrograms/l (n = 956). Monthly sampling for 4-11 months showed that arsenic levels in groundwater from five of the six newly installed wells were consistently within the WHO guideline value of 10 micrograms/l for drinking-water. One of these wells met the Bangladesh standard of 50 micrograms/l arsenic but failed to meet the WHO guideline values for manganese and uranium in drinking-water. The community wells were very popular. Many women walked hundreds of metres each day to fetch water from them. On average, 2200 litres were hand-pumped daily from each community well, regardless of the season. CONCLUSION: A single community well can meet the needs of some 500 people residing within a radius of 150 m of it in a densely populated village. Properly monitored community wells should become more prominent in campaigns to reduce arsenic exposure in Bangladesh. Between 8000 and 10,000 deep community wells are needed to provide safe water for the four to five million people living in the most severely affected parts of the country. PMID:14710504

  3. Community wells to mitigate the arsenic crisis in Bangladesh.

    PubMed

    van Geen, Alexander; Ahmed, K M; Seddique, A A; Shamsudduha, M

    2003-01-01

    To monitor the effectiveness of deep community wells in reducing exposure to elevated levels of arsenic in groundwater pumped from shallower aquifers. Six community wells ranging in depth from 60 m to 140 m were installed in villages where very few of the wells already present produced safe water. By means of flow meters and interviews with villagers carrying water from the community wells, a study was made of the extent to which these were used during one year. The results were compared with household and well data obtained during a previous survey in the same area. The mean arsenic concentration in water pumped from wells already in use in the villages where the community wells, were installed was 180 +/- 140 micrograms/l (n = 956). Monthly sampling for 4-11 months showed that arsenic levels in groundwater from five of the six newly installed wells were consistently within the WHO guideline value of 10 micrograms/l for drinking-water. One of these wells met the Bangladesh standard of 50 micrograms/l arsenic but failed to meet the WHO guideline values for manganese and uranium in drinking-water. The community wells were very popular. Many women walked hundreds of metres each day to fetch water from them. On average, 2200 litres were hand-pumped daily from each community well, regardless of the season. A single community well can meet the needs of some 500 people residing within a radius of 150 m of it in a densely populated village. Properly monitored community wells should become more prominent in campaigns to reduce arsenic exposure in Bangladesh. Between 8000 and 10,000 deep community wells are needed to provide safe water for the four to five million people living in the most severely affected parts of the country.

  4. Advancements in high-power high-brightness laser bars and single emitters for pumping and direct diode application

    NASA Astrophysics Data System (ADS)

    An, Haiyan; Jiang, Ching-Long J.; Xiong, Yihan; Zhang, Qiang; Inyang, Aloysius; Felder, Jason; Lewin, Alexander; Roff, Robert; Heinemann, Stefan; Schmidt, Berthold; Treusch, Georg

    2015-03-01

    We have continuously optimized high fill factor bar and packaging design to increase power and efficiency for thin disc laser system pump application. On the other hand, low fill factor bars packaged on the same direct copper bonded (DCB) cooling platform are used to build multi-kilowatt direct diode laser systems. We have also optimized the single emitter designs for fiber laser pump applications. In this paper, we will give an overview of our recent advances in high power high brightness laser bars and single emitters for pumping and direct diode application. We will present 300W bar development results for our next generation thin disk laser pump source. We will also show recent improvements on slow axis beam quality of low fill factor bar and its application on performance improvement of 4-5 kW TruDiode laser system with BPP of 30 mm*mrad from a 600 μm fiber. Performance and reliability results of single emitter for multiemitter fiber laser pump source will be presented as well.

  5. Clinical review: insulin pump-associated adverse events in adults and children.

    PubMed

    Ross, P L; Milburn, J; Reith, D M; Wiltshire, E; Wheeler, B J

    2015-12-01

    Insulin pumps are a vital and rapidly developing tool in the treatment of type 1 diabetes mellitus in both adults and children. Many studies have highlighted outcomes and assessed their potential advantages, but much of the data on adverse outcomes are limited and often based on outdated technology. We aimed to review and summarize the available literature on insulin pump-associated adverse events in adults and children. A literature search was undertaken using PubMed, EMBASE, and the Cochrane library. Articles were then screened by title, followed by abstract, and full text as needed. A by-hand search of reference lists in identified papers was also utilised. All searches were limited to English language material, but no time limits were used. Current and past literature regarding insulin pump-associated adverse events is discussed, including potential metabolic and non-metabolic adverse events, in particular: pump malfunction; infusion set/site issues; and cutaneous problems. We show that even with modern technology, adverse events are common, occurring in over 40 % of users per year, with a minority, particularly in children, requiring hospital management. Hyperglycaemia and ketosis are now the most common consequences of adverse events and are usually associated with infusion set failure. This differs from older technology where infected infusion sites predominated. This timely review covers all potential insulin pump-associated adverse events, including their incidence, features, impacts, and contributory factors such as the pump user. The importance of ongoing anticipatory education and support for patients and families using this intensive insulin technology is highlighted, which if done well should improve the overall experience of pump therapy for users, and hopefully reduce the incidence and impact of severe adverse events.

  6. Neural Network approach to assess the thermal affected zone around the injection well in a groundwater heat pump system

    NASA Astrophysics Data System (ADS)

    Lo Russo, Stefano; Taddia, Glenda; Verda, Vittorio

    2014-05-01

    The common use of well doublets for groundwater-sourced heating or cooling results in a thermal plume of colder or warmer re-injected groundwater known as the Thermal Affected Zone(TAZ). The plumes may be regarded either as a potential anthropogenic geothermal resource or as pollution, depending on downstream aquifer usage. A fundamental aspect in groundwater heat pump (GWHP) plant design is the correct evaluation of the thermally affected zone that develops around the injection well. Temperature anomalies are detected through numerical methods. Crucial elements in the process of thermal impact assessment are the sizes of installations, their position, the heating/cooling load of the building, and the temperature drop/increase imposed on the re-injected water flow. For multiple-well schemes, heterogeneous aquifers, or variable heating and cooling loads, numerical models that simulate groundwater and heat transport are needed. These tools should consider numerous scenarios obtained considering different heating/cooling loads, positions, and operating modes. Computational fluid dynamic (CFD) models are widely used in this field because they offer the opportunity to calculate the time evolution of the thermal plume produced by a heat pump, depending on the characteristics of the subsurface and the heat pump. Nevertheless, these models require large computational efforts, and therefore their use may be limited to a reasonable number of scenarios. Neural networks could represent an alternative to CFD for assessing the TAZ under different scenarios referring to a specific site. The use of neural networks is proposed to determine the time evolution of the groundwater temperature downstream of an installation as a function of the possible utilization profiles of the heat pump. The main advantage of neural network modeling is the possibility of evaluating a large number of scenarios in a very short time, which is very useful for the preliminary analysis of future multiple

  7. Outcome of Cardiac Rehabilitation Following Off-Pump Versus On-Pump Coronary Bypass Surgery

    PubMed Central

    Arefizadeh, Reza; Hariri, Seyed Yaser; Moghadam, Adel Johari

    2017-01-01

    BACKGROUND: A few studies have compared the cardiac rehabilitation (CR) outcome between those who undergo conventional on-pump bypass surgery and off-pump surgery. We compared this outcome among the patients differentiated by the On-pump and off-pump surgical procedures about cardiovascular variables and psychological status. METHODS: This longitudinal study recruited 318 and 102 consecutive patients who had undergone CABG (on-pump surgery, n = 318 and off-pump surgery, n = 102) and been referred to the CR clinic. RESULTS: The off-pump surgery patients had more improvement in their metabolic equivalents (METs) value. The physical and mental components of health-related quality of life (QOL) (based on SF-36 questionnaire) as well as depression-anxiety (based on Costello-Comrey Depression and Anxiety Scale) were notably improved in the two study groups after the CR program, while changes in the QOL components scores and also depression-anxiety score were not different between the off-pump and on-pump techniques. CONCLUSIONS: Regarding QOL and psychological status, there were no differences in the CR outcome between those who underwent off-pump bypass surgery and those who underwent on-pump surgery; nevertheless, the off-pump technique was superior to the on-pump method on METs improvement following CR. PMID:28698744

  8. Outcome of Cardiac Rehabilitation Following Off-Pump Versus On-Pump Coronary Bypass Surgery.

    PubMed

    Arefizadeh, Reza; Hariri, Seyed Yaser; Moghadam, Adel Johari

    2017-06-15

    A few studies have compared the cardiac rehabilitation (CR) outcome between those who undergo conventional on-pump bypass surgery and off-pump surgery. We compared this outcome among the patients differentiated by the On-pump and off-pump surgical procedures about cardiovascular variables and psychological status. This longitudinal study recruited 318 and 102 consecutive patients who had undergone CABG (on-pump surgery, n = 318 and off-pump surgery, n = 102) and been referred to the CR clinic. The off-pump surgery patients had more improvement in their metabolic equivalents (METs) value. The physical and mental components of health-related quality of life (QOL) (based on SF-36 questionnaire) as well as depression-anxiety (based on Costello-Comrey Depression and Anxiety Scale) were notably improved in the two study groups after the CR program, while changes in the QOL components scores and also depression-anxiety score were not different between the off-pump and on-pump techniques. Regarding QOL and psychological status, there were no differences in the CR outcome between those who underwent off-pump bypass surgery and those who underwent on-pump surgery; nevertheless, the off-pump technique was superior to the on-pump method on METs improvement following CR.

  9. Recommendations and requirements for soap and hand rub dispensers in healthcare facilities.

    PubMed

    Assadian, Ojan; Kramer, Axel; Christiansen, Bärbel; Exner, Martin; Martiny, Heike; Sorger, Arno; Suchomel, Miranda

    2012-01-01

    Hand hygiene is one of the most important measures to prevent transmission of infectious agents and plays a major role in prevention of infection in any type of healthcare setting. While requirements for the efficacy of hand disinfectants are defined in European testing norms such as the EN 1500 for hygienic hand disinfection or EN 12791 for surgical hand preparation, no specific recommendations for hand rub dispensers and liquid soap dispensers have been given yet. Therefore, the intention of the present recommendation on soap and hand rub dispensers in healthcare facilities is to close this gap and to enhance future improvement of dispenser functionality and design. Regardless of manufacture and design of a hand rub or liquid soap dispensers the following requirements shall be met in healthcare facilities:Triggering the dispenser must be possible without using hands. Sensor- or elbow-operated dispensers both fulfill this requirement. Dispensers must be only refillable in a modality where the content, be it a hand rub or liquid soap, cannot be contaminated. This is achieved best by using replaceable cartridge systems. Refilling through "top-up" must not be possible. The disperser should allow usage of different types of cartridges made by different manufacturers. Dispensers must be operated and maintained such that a microbial contamination of the pump nozzle may easily be avoided. It must be possible to identify the products used in a dispenser easily and without any manipulation. Identifying the type of product, be it a hand rub or a liquid soap, as well as reading the product's name and critical manufacturers' warnings must be possible at any time. The disperser must allow identification of the level of the used product without any further manipulation at any time. The design of the dispenser must allow easy cleaning and disinfection the outside and inside of the dispenser. The manufacturer of the dispenser must provide the user with information on applicable

  10. GAS METERING PUMP

    DOEpatents

    George, C.M.

    1957-12-31

    A liquid piston gas pump is described, capable of pumping minute amounts of gas in accurately measurable quantities. The pump consists of a flanged cylindrical regulating chamber and a mercury filled bellows. Sealed to the ABSTRACTS regulating chamber is a value and having a gas inlet and outlet, the inlet being connected by a helical channel to the bellows. A gravity check valve is in the gas outlet, so the gas passes through the inlet and the helical channel to the bellows where the pumping action as well as the metering is accomplished by the actuation of the mercury filled bellows. The gas then flows through the check valve and outlet to any associated apparatus.

  11. Microbial Groundwater Quality Status of Hand-Dug Wells and Boreholes in the Dodowa Area of Ghana

    PubMed Central

    Lutterodt, George; Hoiting, Yvonne; Kamara, Alimamy K.; Oduro-Kwarteng, Sampson; Foppen, Jan Willem A.

    2018-01-01

    To assess the suitability of water sources for drinking purposes, samples were taken from groundwater sources (boreholes and hand-dug wells) used for drinking water in the Dodowa area of Ghana. The samples were analyzed for the presence of fecal indicator bacteria (Escherichia coli) and viruses (Adenovirus and Rotavirus), using membrane filtration with plating and glass wool filtration with quantitative polymerase chain reaction (PCR), respectively. In addition, sanitary inspection of surroundings of the sources was conducted to identify their vulnerability to pollution. The presence of viruses was also assessed in water samples from the Dodowa River. More than 70% of the hand-dug wells were sited within 10 m of nearby sources of contamination. All sources contained E. coli bacteria, and their numbers in samples of water between dug wells and boreholes showed no significant difference (p = 0.48). Quantitative PCR results for Adenovirus indicated 27% and 55% were positive for the boreholes and hand-dug wells, respectively. Samples from all boreholes tested negative for the presence of Rotavirus while 27% of the dug wells were positive for Rotavirus. PCR tests of 20% of groundwater samples were inhibited. Based on these results we concluded that there is systemic microbial and fecal contamination of groundwater in the area. On-site sanitation facilities, e.g., pit latrines and unlined wastewater drains, are likely the most common sources of fecal contamination of groundwater in the area. Water abstracted from groundwater sources needs to be treated before use for consumption purposes. In addition, efforts should be made to delineate protected areas around groundwater abstraction points to minimize contamination from point sources of pollution. PMID:29649111

  12. Energy dissipation in slipping biological pumps.

    PubMed

    Kjelstrup, Signe; Rubi, J Miguel; Bedeaux, Dick

    2005-12-07

    We describe active transport in slipping biological pumps, using mesoscopic nonequilibrium thermodynamics. The pump operation is characterised by its stochastic nature and energy dissipation. We show how heating as well as cooling effects can be associated with pump operation. We use as an example the well studied active transport of Ca2+ across a biological membrane by means of its ATPase, and use published data to find values for the transport coefficients of the pump under various conditions. Most of the transport coefficients of the pump, including those that relate ATP hydrolysis or synthesis to thermal effects, are estimated. This can give a quantitative description of thermogenesis. We show by calculation that all of these coupling coefficients are significant.

  13. Rod pumping and proppant flowback at the Lost Hills Field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roberts, I.G.

    1995-12-31

    Proppant flowback from hydraulically fractured wells can lead to sand wear on the pump barrel and plunger and increased pulling costs on rod pumped wells. Two approaches for lengthening run times of the pumps were tried. One approach was to install pumps that will allow production of a sand laden fluid. Pressure actuated plunger (PAP) pumps were field tested and showed an average increase of 81.6% in run time. These split ring wiper pumps clean the barrel of sand prior to the passing of the plunger. The other approach was to keep the sand and from entering the pumps. Whenmore » down hole filters were utilized, run life of the pumps with the filters increases 135%. Well pulling cost savings of $11.91 per well-day and $9.24 per well-day are documented for the PAP pumps and filters, respectively. Application guidelines based on the sand loading rate and gross liquid production of the wells are presented, as well as some operational experiences.« less

  14. Estimation of the transmissivity of thin leaky-confined aquifers from single-well pumping tests

    NASA Astrophysics Data System (ADS)

    Worthington, Paul F.

    1981-01-01

    Data from the quasi-equilibrium phases of a step-drawdown test are used to evaluate the coefficient of non-linear head losses subject to the assumption of a constant effective well radius. After applying a well-loss correction to the observed drawdowns of the first step, an approximation method is used to estimate a pseudo-transmissivity of the aquifer from a single value of time-variant drawdown. The pseudo-transmissivities computed for each of a sequence of values of time pass through a minimum when there is least manifestation of casing-storage and leakage effects, phenomena to which pumping-test data of this kind are particularly susceptible. This minimum pseudo-transmissivity, adjusted for partial penetration effects where appropriate, constitutes the best possible estimate of aquifer transmissivity. The ease of application of the overall procedure is illustrated by a practical example.

  15. Electroosmotic pumps for microflow analysis

    PubMed Central

    Wang, Xiayan; Wang, Shili; Gendhar, Brina; Cheng, Chang; Byun, Chang Kyu; Li, Guanbin; Zhao, Meiping; Liu, Shaorong

    2009-01-01

    With rapid development in microflow analysis, electroosmotic pumps are receiving increasing attention. Compared to other micropumps, electroosmotic pumps have several unique features. For example, they are bi-directional, can generate constant and pulse-free flows with flow rates well suited to microanalytical systems, and can be readily integrated with lab-on-chip devices. The magnitude and the direction of flow of an electroosmotic pump can be changed instantly. In addition, electroosmotic pumps have no moving parts. In this article, we discuss common features, introduce fabrication technologies and highlight applications of electroosmotic pumps. PMID:20047021

  16. Analysis of glycols, glycol ethers, and other volatile organic compounds present in household water-based hand pump sprays.

    PubMed

    Kawakami, Tsuyoshi; Isama, Kazuo; Tanaka-Kagawa, Toshiko; Jinnno, Hideto

    2017-11-10

    The aim of this investigation is to clarify the types and concentrations of VOCs present in various commercial household water-based hand pump spray products used in Japan, and to estimate their average concentrations in indoor air when the spray product is used. We selected glycol and glycol ethers as the main target compounds, as these chemicals were detected at high frequencies and concentrations in a national survey of Japanese indoor air pollution. The extraction of these chemicals using graphite carbon cartridges was examined, with good recoveries and reproducibilities being obtained. Eighteen chemicals were analyzed in 54 commercial products and 8 chemicals were detected. More specifically, dipropylene glycol (DPG) was present in 44 samples (1.1 × 10 1 -1.8 × 10 4 μg/mL); propylene glycol (PG) was present in 22 samples (1.5 × 10 1 -2.9 × 10 4 μg/mL); diethylene glycol monoethyl ether (DGMEE) was found in 15 samples (trace amount-1.9 × 10 3 μg/mL); diethylene glycol (DEG) was present in 9 samples (1.0 × 10 1 -2.4 × 10 3 μg/mL); 1,3-butandiol (13BG) was found in 5 samples (trace amount-7.4 × 10 3 μg/mL); 2-ethyl-1-hexanol (2E1H) was detected in 5 samples (3.2 × 10 -1 -4.4 × 10 1 μg/mL); diethylene glycol monobutyl ether (DGMBE) was present in 4 samples (2.1 × 10 1 -7.1 × 10 1 μg/mL); and 3-methoxy-3-methylbutanol (MMB) was found in 2 samples (2.4 × 10 1 -4.7 × 10 2 μg/mL). In addition, the average concentrations of these chemicals in indoor air were estimated using their maximum concentrations observed in the spray product. The estimated average concentrations of the chemicals in indoor air were determined to range between 1.0 × 10 -2 and 1.0 mg/m 3 , with the exception of 2E1H and DGMBE. Furthermore, the estimated average concentrations of PG, 13BG, and DGMEE in indoor air were comparable to or higher than those reported in a national survey of Japanese indoor air pollution. It therefore appeared that household water-based hand pump

  17. Investigation of Enersave series 500 pump. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, P.R.

    A new type of pump to be used as a stripper pump for oil wells has been developed by Enersave Pumps, Incorporated of Roswell, New Mexico. The Enersave 500 pump has no moving mechanical parts between the down-hole pistons which lift the fluid and the driving unit at the surface. Rather, a pressure pulse created by the driving unit, usually called the pulser, is transmitted through the fluid in the well string to the down-hole unit and creates the pumping action. Object of the project was to optimize the configuration of the pump, that is, increase the production flow ratemore » while minimizing the energy consumption needed to obtain this flow rate. New Mexico State University's role in this project was to model the pump using computer techniques to provide guidelines for improvement in pump design, to supervise the performance of field and bench testing of the redesigned versions of the pump to validate the actual performance of the pump, and to provide a life cycle cost analysis of the pump. Experimental results at depths to as much as 1729 feet show that the redesigned pump will deliver 3 gpm with an average power input of about 1 hp. The energy requirements of the Enersave 500 pump are on the average 25% lower than the energy requirements of an equivalent pump-jack, the typical pump now used in the oil fields for stripper well operation. Further, a life cycle cost analysis of the Enersave 500 pump compared to an equivalent pump-jack shows the Enersave 500 pump to be more economical to purchase and operate.« less

  18. Demonstration optimization analyses of pumping from selected Arapahoe aquifer municipal wells in the west-central Denver Basin, Colorado, 2010–2109

    USGS Publications Warehouse

    Banta, Edward R.; Paschke, Suzanne S.

    2012-01-01

    Declining water levels caused by withdrawals of water from wells in the west-central part of the Denver Basin bedrock-aquifer system have raised concerns with respect to the ability of the aquifer system to sustain production. The Arapahoe aquifer in particular is heavily used in this area. Two optimization analyses were conducted to demonstrate approaches that could be used to evaluate possible future pumping scenarios intended to prolong the productivity of the aquifer and to delay excessive loss of saturated thickness. These analyses were designed as demonstrations only, and were not intended as a comprehensive optimization study. Optimization analyses were based on a groundwater-flow model of the Denver Basin developed as part of a recently published U.S. Geological Survey groundwater-availability study. For each analysis an optimization problem was set up to maximize total withdrawal rate, subject to withdrawal-rate and hydraulic-head constraints, for 119 selected municipal water-supply wells located in 96 model cells. The optimization analyses were based on 50- and 100-year simulations of groundwater withdrawals. The optimized total withdrawal rate for all selected wells for a 50-year simulation time was about 58.8 cubic feet per second. For an analysis in which the simulation time and head-constraint time were extended to 100 years, the optimized total withdrawal rate for all selected wells was about 53.0 cubic feet per second, demonstrating that a reduction in withdrawal rate of about 10 percent may extend the time before the hydraulic-head constraints are violated by 50 years, provided that pumping rates are optimally distributed. Analysis of simulation results showed that initially, the pumping produces water primarily by release of water from storage in the Arapahoe aquifer. However, because confining layers between the Denver and Arapahoe aquifers are thin, in less than 5 years, most of the water removed by managed-flows pumping likely would be supplied

  19. Design of three-well indirect pumping terahertz quantum cascade lasers for high optical gain based on nonequilibrium Green's function analysis

    NASA Astrophysics Data System (ADS)

    Liu, Tao; Kubis, Tillmann; Jie Wang, Qi; Klimeck, Gerhard

    2012-03-01

    The nonequilibrium Green's function approach is applied to the design of three-well indirect pumping terahertz (THz) quantum cascade lasers (QCLs) based on a resonant phonon depopulation scheme. The effects of the anticrossing of the injector states and the dipole matrix element of the laser levels on the optical gain of THz QCLs are studied. The results show that a design that results in a more pronounced anticrossing of the injector states will achieve a higher optical gain in the indirect pumping scheme compared to the traditional resonant-tunneling injection scheme. This offers in general a more efficient coherent resonant-tunneling transport of electrons in the indirect pumping scheme. It is also shown that, for operating temperatures below 200 K and low lasing frequencies, larger dipole matrix elements, i.e., vertical optical transitions, offer a higher optical gain. In contrast, in the case of high lasing frequencies, smaller dipole matrix elements, i.e., diagonal optical transitions are better for achieving a higher optical gain.

  20. Hand-portable liquid chromatographic instrumentation.

    PubMed

    Sharma, Sonika; Tolley, Luke T; Tolley, H Dennis; Plistil, Alex; Stearns, Stanley D; Lee, Milton L

    2015-11-20

    Over the last four decades, liquid chromatography (LC) has experienced an evolution to smaller columns and particles, new stationary phases and low flow rate instrumentation. However, the development of person-portable LC has not followed, mainly due to difficulties encountered in miniaturizing pumps and detectors, and in reducing solvent consumption. The recent introduction of small, non-splitting pumping systems and UV-absorption detectors for use with capillary columns has finally provided miniaturized instrumentation suitable for high-performance hand-portable LC. Fully integrated microfabricated LC still remains a significant challenge. Ion chromatography (IC) has been successfully miniaturized and applied for field analysis; however, applications are mostly limited to inorganic and small organic ions. This review covers advancements that make possible more rapid expansion of portable forms of LC and IC. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. IMPROVEMENTS IN PUMP INTAKE BASIN DESIGN

    EPA Science Inventory

    Pump intake basins (or wet wells or pump sumps) designed in accordance with accepted criteria often pose many operation and maintenance problems. The report summarizes field surveys of three trench-type pump intake basins representative of 29 such basins that have been in satisfa...

  2. 30. (Credit JTL) Old 19111912 low service pump pit and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. (Credit JTL) Old 1911-1912 low service pump pit and receiving well in background. Platform and well in foreground constructed in 1977 for #6 and #7 electric low service pumps (#6 pump moved from old receiving well; #7 installed new). - McNeil Street Pumping Station, McNeil Street & Cross Bayou, Shreveport, Caddo Parish, LA

  3. Hydraulic jet pumping in a remote location

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tjondrodiputro, B.; Gaul, R.B.; Gower, G.H.

    1986-12-01

    Hydraulic jet pumping equipment was installed in six Sembakung field (N.E. Kalimantan) wells by Atlantic Richfield Indonesia Inc., for Pertamina during 1983, and this article presents the experience acquired in the process of installing and operating this type of artificial-lift equipment in a remote location. Characteristics of the wells and equipment are reviewed, and possible future installations in similar circumstances are discussed. Sembakung oil field, discovered in late 1975, contained 17 wells after complete development. By 1983, some were flowing weakly and several zones were dead, indicating the need for some form of artificial lift. The choice of artificial liftmore » methods was limited by the lack of gas-lift gas, absence of a field-wide power distribution system, unavailability of a rod pumping well servicing unit, and lack of roads in the marshy environment. Thus, hydraulic (free-type) jet pumping was selected as the optimum technique. Jet pumps were installed in six of 17 wells in the field at the end of 1983. Downhole equipment was installed using a heli-rig, and all surface equipment was delivered to location using helicopters. Since startup, some operating problems occurred, but they have all been resolved. Well pumping rates range from 340 to 650 bpd gross, with 0 to 50% BSandW. The jet-pumped wells produced satisfactorily through July 1984, at which time operations were turned over to Pertamina Unit IV at the conclusion of the contractual term.« less

  4. Automatic estimation of aquifer parameters using long-term water supply pumping and injection records

    NASA Astrophysics Data System (ADS)

    Luo, Ning; Illman, Walter A.

    2016-09-01

    Analyses are presented of long-term hydrographs perturbed by variable pumping/injection events in a confined aquifer at a municipal water-supply well field in the Region of Waterloo, Ontario (Canada). Such records are typically not considered for aquifer test analysis. Here, the water-level variations are fingerprinted to pumping/injection rate changes using the Theis model implemented in the WELLS code coupled with PEST. Analyses of these records yield a set of transmissivity ( T) and storativity ( S) estimates between each monitoring and production borehole. These individual estimates are found to poorly predict water-level variations at nearby monitoring boreholes not used in the calibration effort. On the other hand, the geometric means of the individual T and S estimates are similar to those obtained from previous pumping tests conducted at the same site and adequately predict water-level variations in other boreholes. The analyses reveal that long-term municipal water-level records are amenable to analyses using a simple analytical solution to estimate aquifer parameters. However, uniform parameters estimated with analytical solutions should be considered as first rough estimates. More accurate hydraulic parameters should be obtained by calibrating a three-dimensional numerical model that rigorously captures the complexities of the site with these data.

  5. On the aquitard-aquifer interface flow and the drawdown sensitivity with a partially penetrating pumping well in an anisotropic leaky confined aquifer

    NASA Astrophysics Data System (ADS)

    Feng, Qinggao; Zhan, Hongbin

    2015-02-01

    A mathematical model for describing groundwater flow to a partially penetrating pumping well of a finite diameter in an anisotropic leaky confined aquifer is developed. The model accounts for the jointed effects of aquitard storage, aquifer anisotropy, and wellbore storage by treating the aquitard leakage as a boundary condition at the aquitard-aquifer interface rather than a volumetric source/sink term in the governing equation, which has never developed before. A new semi-analytical solution for the model is obtained by the Laplace transform in conjunction with separation of variables. Specific attention was paid on the flow across the aquitard-aquifer interface, which is of concern if aquitard and aquifer have different pore water chemistry. Moreover, Laplace-domain and steady-state solutions are obtained to calculate the rate and volume of (total) leakage through the aquitard-aquifer interface due to pump in a partially penetrating well, which is also useful for engineers to manager water resources. The sensitivity analyses for the drawdown illustrate that the drawdown is most sensitive to the well partial penetration. It is apparently sensitive to the aquifer anisotropic ratio over the entire time of pumping. It is moderately sensitive to the aquitard/aquifer specific storage ratio at the intermediate times only. It is moderately sensitive to the aquitard/aquifer vertical hydraulic conductivity ratio and the aquitard/aquifer thickness ratio with the identical influence at late times.

  6. Controlling groundwater pumping online.

    PubMed

    Zekri, Slim

    2009-08-01

    Groundwater over-pumping is a major problem in several countries around the globe. Since controlling groundwater pumping through water flow meters is hardly feasible, the surrogate is to control electricity usage. This paper presents a framework to restrict groundwater pumping by implementing an annual individual electricity quota without interfering with the electricity pricing policy. The system could be monitored online through prepaid electricity meters. This provides low transaction costs of individual monitoring of users compared to the prohibitive costs of water flow metering and monitoring. The public groundwater managers' intervention is thus required to determine the water and electricity quota and watch the electricity use online. The proposed framework opens the door to the establishment of formal groundwater markets among users at very low transaction costs. A cost-benefit analysis over a 25-year period is used to evaluate the cost of non-action and compare it to the prepaid electricity quota framework in the Batinah coastal area of Oman. Results show that the damage cost to the community, if no active policy is implemented, amounts to (-$288) million. On the other hand, the implementation of a prepaid electricity quota with an online management system would result in a net present benefit of $199 million.

  7. High brightness fiber laser pump sources based on single emitters and multiple single emitters

    NASA Astrophysics Data System (ADS)

    Scheller, Torsten; Wagner, Lars; Wolf, Jürgen; Bonati, Guido; Dörfel, Falk; Gabler, Thomas

    2008-02-01

    Driven by the potential of the fiber laser market, the development of high brightness pump sources has been pushed during the last years. The main approaches to reach the targets of this market had been the direct coupling of single emitters (SE) on the one hand and the beam shaping of bars and stacks on the other hand, which often causes higher cost per watt. Meanwhile the power of single emitters with 100μm emitter size for direct coupling increased dramatically, which also pushed a new generation of wide stripe emitters or multi emitters (ME) of up to 1000μm emitter size respectively "minibars" with apertures of 3 to 5mm. The advantage of this emitter type compared to traditional bars is it's scalability to power levels of 40W to 60W combined with a small aperture which gives advantages when coupling into a fiber. We show concepts using this multiple single emitters for fiber coupled systems of 25W up to 40W out of a 100μm fiber NA 0.22 with a reasonable optical efficiency. Taking into account a further efficiency optimization and an increase in power of these devices in the near future, the EUR/W ratio pushed by the fiber laser manufacturer will further decrease. Results will be shown as well for higher power pump sources. Additional state of the art tapered fiber bundles for photonic crystal fibers are used to combine 7 (19) pump sources to output powers of 100W (370W) out of a 130μm (250μm) fiber NA 0.6 with nominal 20W per port. Improving those TFB's in the near future and utilizing 40W per pump leg, an output power of even 750W out of 250μm fiber NA 0.6 will be possible. Combined Counter- and Co-Propagated pumping of the fiber will then lead to the first 1kW fiber laser oscillator.

  8. Preliminary simulation of chloride transport in the Equus Beds aquifer and simulated effects of well pumping and artificial recharge on groundwater flow and chloride transport near the city of Wichita, Kansas, 1990 through 2008

    USGS Publications Warehouse

    Klager, Brian J.; Kelly, Brian P.; Ziegler, Andrew C.

    2014-01-01

    The Equus Beds aquifer in south-central Kansas is a primary water-supply source for the city of Wichita. Water-level declines because of groundwater pumping for municipal and irrigation needs as well as sporadic drought conditions have caused concern about the adequacy of the Equus Beds aquifer as a future water supply for Wichita. In March 2006, the city of Wichita began construction of the Equus Beds Aquifer Storage and Recovery project, a plan to artificially recharge the aquifer with excess water from the Little Arkansas River. Artificial recharge will raise groundwater levels, increase storage volume in the aquifer, and deter or slow down a plume of chloride brine approaching the Wichita well field from the Burrton, Kansas area caused by oil production activities in the 1930s. Another source of high chloride water to the aquifer is the Arkansas River. This study was prepared in cooperation with the city of Wichita as part of the Equus Beds Aquifer Storage and Recovery project. Chloride transport in the Equus Beds aquifer was simulated between the Arkansas and Little Arkansas Rivers near the Wichita well field. Chloride transport was simulated for the Equus Beds aquifer using SEAWAT, a computer program that combines the groundwater-flow model MODFLOW-2000 and the solute-transport model MT3DMS. The chloride-transport model was used to simulate the period from 1990 through 2008 and the effects of five well pumping scenarios and one artificial recharge scenario. The chloride distribution in the aquifer for the beginning of 1990 was interpolated from groundwater samples from around that time, and the chloride concentrations in rivers for the study period were interpolated from surface water samples. Five well-pumping scenarios and one artificial-recharge scenario were assessed for their effects on simulated chloride transport and water levels in and around the Wichita well field. The scenarios were: (1) existing 1990 through 2008 pumping conditions, to serve as a

  9. Impact of Spatial Pumping Patterns on Groundwater Management

    NASA Astrophysics Data System (ADS)

    Yin, J.; Tsai, F. T. C.

    2017-12-01

    Challenges exist to manage groundwater resources while maintaining a balance between groundwater quantity and quality because of anthropogenic pumping activities as well as complex subsurface environment. In this study, to address the impact of spatial pumping pattern on groundwater management, a mixed integer nonlinear multi-objective model is formulated by integrating three objectives within a management framework to: (i) maximize total groundwater withdrawal from potential wells; (ii) minimize total electricity cost for well pumps; and (iii) attain groundwater level at selected monitoring locations as close as possible to the target level. Binary variables are used in the groundwater management model to control the operative status of pumping wells. The NSGA-II is linked with MODFLOW to solve the multi-objective problem. The proposed method is applied to a groundwater management problem in the complex Baton Rouge aquifer system, southeastern Louisiana. Results show that (a) non-dominated trade-off solutions under various spatial distributions of active pumping wells can be achieved. Each solution is optimal with regard to its corresponding objectives; (b) operative status, locations and pumping rates of pumping wells are significant to influence the distribution of hydraulic head, which in turn influence the optimization results; (c) A wide range of optimal solutions is obtained such that decision makers can select the most appropriate solution through negotiation with different stakeholders. This technique is beneficial to finding out the optimal extent to which three objectives including water supply concern, energy concern and subsidence concern can be balanced.

  10. Pressure charged airlift pump

    DOEpatents

    Campbell, Gene K.

    1983-01-01

    A pumping system is described for pumping fluids, such as water with entrained mud and small rocks, out of underground cavities such as drilled wells, which can effectively remove fluids down to a level very close to the bottom of the cavity and which can operate solely by compressed air pumped down through the cavity. The system utilizes a subassembly having a pair of parallel conduit sections (44, 46) adapted to be connected onto the bottom of a drill string utilized for drilling the cavity, the drill string also having a pair of coaxially extending conduits. The subassembly includes an upper portion which has means for connection onto the drill string and terminates the first conduit of the drill string in a plenum (55). A compressed air-driven pump (62) is suspended from the upper portion. The pump sucks fluids from the bottom of the cavity and discharges them into the second conduit. Compressed air pumped down through the first conduit (46) to the plenum powers the compressed air-driven pump and aerates the fluid in the second conduit to lift it to the earth's surface.

  11. Phase dynamics of oscillating magnetizations coupled via spin pumping

    NASA Astrophysics Data System (ADS)

    Taniguchi, Tomohiro

    2018-05-01

    A theoretical formalism is developed to simultaneously solve equation of motion of the magnetizations in two ferromagnets and the spin-pumping induced spin transport equation. Based on the formalism, a coupled motion of the magnetizations in a self-oscillation state is studied. The spin pumping is found to induce an in-phase synchronization of the magnetizations for the oscillation around the easy axis. For an out-of-plane self-oscillation around the hard axis, on the other hand, the spin pumping leads to an in-phase synchronization in a small current region, whereas an antiphase synchronization is excited in a large current region. An analytical theory based on the phase equation reveals that the phase difference between the magnetizations in a steady state depends on the oscillation direction, clockwise or counterclockwise, of the magnetizations.

  12. Absorption heat pump for space applications

    NASA Technical Reports Server (NTRS)

    Nguyen, Tuan; Simon, William E.; Warrier, Gopinath R.; Woramontri, Woranun

    1993-01-01

    In the first part, the performance of the Absorption Heat Pump (AHP) with water-sulfuric acid and water-magnesium chloride as two new refrigerant-absorbent fluid pairs was investigated. A model was proposed for the analysis of the new working pairs in a heat pump system, subject to different temperature lifts. Computer codes were developed to calculate the Coefficient of Performance (COP) of the system with the thermodynamic properties of the working fluids obtained from the literature. The study shows the potential of water-sulfuric acid as a satisfactory replacement for water-lithium bromide in the targeted temperature range. The performance of the AHP using water-magnesium chloride as refrigerant-absorbent pair does not compare well with those obtained using water-lithium bromide. The second part concentrated on the design and testing of a simple ElectroHydrodynamic (EHD) Pump. A theoretical design model based on continuum electromechanics was analyzed to predict the performance characteristics of the EHD pump to circulate the fluid in the absorption heat pump. A numerical method of solving the governing equations was established to predict the velocity profile, pressure - flow rate relationship and efficiency of the pump. The predicted operational characteristics of the EHD pump is comparable to that of turbomachinery hardware; however, the overall efficiency of the electromagnetic pump is much lower. An experimental investigation to verify the numerical results was conducted. The pressure - flow rate performance characteristics and overall efficiency of the pump obtained experimentally agree well with the theoretical model.

  13. Hand dug wells in Namibia: An underestimated water source or a threat to human health?

    NASA Astrophysics Data System (ADS)

    Wanke, H.; Nakwafila, A.; Hamutoko, J. T.; Lohe, C.; Neumbo, F.; Petrus, I.; David, A.; Beukes, H.; Masule, N.; Quinger, M.

    The rural population of parts of northern and western Namibia uses hand dug wells for their domestic water supply, partly because no other source (e.g., deep tube wells) is available, but also as a substitute for pipeline water that is often perceived as being too expensive. The water quality of these wells is usually not monitored or controlled, thus a study has been carried out in four study areas in Namibia: southern Omusati/Oshana area, Okongo/Ohangwena area, Omatjete/Omaruru area, Okanguati/Kunene area. Hand dug wells have been tested for on-site parameters: electric conductivity, pH and temperature while samples were taken for major inorganic constituents and several minor and trace constituents including fluoride and nitrate. In addition a sampling campaign in 2010 included the determination of coliform bacteria and Escherichia coli. Results were classified according to the Namibian Water Guidelines. The constituents making the water unfit for human consumption are fluoride, nitrate, sulphate and total dissolved solids. Contamination by E. coli was indicated in nearly all wells that are used for livestock watering. For the Omatjete/Omaruru study area an isotope based study on the source of nitrate has indicated manure as a source. The range of recharge values obtained for the studied villages ranges from 1 mm/a to locally more than 100 mm/a. Overall the water resource in the shallow perched aquifers in the study areas is in many places inappropriate for human consumption. Treatment to improve the quality or introduction of protection measures is necessary to bring this resource to an acceptable quality according to national and/or international standards.

  14. Evaluation of Pumping Rate vs Drawdown vs Distance to Assist in the Development of Balanced Well Spacing Rules

    NASA Astrophysics Data System (ADS)

    Piemonti, A. D.; Oliver, W.

    2017-12-01

    Due to the significant and increasing demand for groundwater in Texas, evaluations of groundwater pumping impacts play an important role in water planning and management. Since 1951, Groundwater Conservation Districts (GCDs) have managed aquifers across much of the state. Among their functions, GCDs can regulate the spacing of new wells from existing wells, but they must balance a landowner's ability to drill a new well with expected impacts to existing wells. We performed studies for three GCDs to provide, based on representative hydraulic properties, the expected impacts of different well spacing and production rate relationships. This was done with the analytic element groundwater modeling code TTIM. These evaluations account for drawdown caused by a single well and cumulative drawdown by many wells. The results consist of a series of plots that allow decision-makers and GCDs representatives to understand the impacts of potential well spacing rule options on existing and prospective well owners.

  15. Designing optically pumped InGaN quantum wells with long wavelength emission for a phosphor-free device with polarized white-light emission

    NASA Astrophysics Data System (ADS)

    Kowsz, Stacy J.; Pynn, Christopher D.; Wu, Feng; Farrell, Robert M.; Speck, James S.; DenBaars, Steven P.; Nakamura, Shuji

    2016-02-01

    We report a semipolar III-nitride device in which an electrically injected blue light emitting diode optically pumps monolithic long wavelength emitting quantum wells (QWs) to create polarized white light. We have demonstrated an initial device with emission peaks at 440 nm and 560 nm from the electrically injected and optically pumped QWs, respectively. By tuning the ratio of blue to yellow, white light was measured with a polarization ratio of 0.40. High indium content InGaN is required for long wavelength emission but is difficult to achieve because it requires low growth temperatures and has a large lattice mismatch with GaN. This device design incorporates optically pumped QWs for long wavelength emission because they offer advantages over using electrically injected QWs. Optically pumped QWs do not have to be confined within a p-n junction, and carrier transport is not a concern. Thus, thick GaN barriers can be incorporated between multiple InGaN QWs to manage stress. Optically pumping long wavelength emitting QWs also eliminates high temperature steps that degrade high indium content InGaN but are required when growing p-GaN for an LED structure. Additionally, by eliminating electrical injection, the doping profile can instead be engineered to affect the emission wavelength. We discuss ongoing work focused on improving polarized white light emission by optimizing the optically pumped QWs. We consider the effects of growth conditions, including: trimethylindium (TMI) flow rate, InGaN growth rate, and growth temperature. We also examine the effects of epitaxial design, including: QW width, number of QWs, and doping.

  16. Characterizing Structural and Stratigraphic Heterogeneities in a Faulted Aquifer Using Pump Tests with an Array of Westbay Multilevel Monitoring Wells

    NASA Astrophysics Data System (ADS)

    Johnson, B.; Zhurina, E. N.

    2001-12-01

    We are developing and assessing field testing and analysis methodologies for quantitative characterization of aquifer heterogenities using data measured in an array of multilevel monitoring wells (MLW) during pumping and recovery well tests. We have developed a unique field laboratory to determine the permeability field in a 20m by 40m by 70m volume in the fault partitioned, siliciclastic Hickory aquifer system in central Texas. The site incorporates both stratigraphic variations and a normal fault system that partially offsets the aquifer and impedes cross-fault flow. We constructed a high-resolution geologic model of the site based upon 1050 m of core and a suite of geophysical logs from eleven, closely spaced (3-10m), continuously cored boreholes to depths of 125 m. Westbay multilevel monitoring systems installed in eight holes provide 94 hydraulically isolated measurement zones and 25 injection zones. A good geologic model is critical to proper installation of the MLW. Packers are positioned at all significant fault piercements and selected, laterally extensive, clay-rich strata. Packers in adjacent MLW bracket selected hydrostratigraphic intervals. Pump tests utilized two, uncased, fully penetrating irrigation wells that straddle the fault system and are in close proximity (7 to 65 m) to the MLW. Pumping and recovery transient pressure histories were measured in 85 zones using pressure transducers with a resolution of 55 Pa (0.008 psi). The hydraulic response is that of an anisotropic, unconfined aquifer. The transient pressure histories vary significantly from zone to zone in a single MLW as well as between adjacent MLW. Derivative plots are especially useful for differentiating details of pressure histories. Based on the geologic model, the derivative curve of a zone reflects its absolute vertical position, vertical stratigraphic position, and proximity to either a fault or significant stratigraphic heterogeneity. Additional forward modeling is needed to

  17. A single center's conversion from roller pump to centrifugal pump technology in extracorporeal membrane oxygenation.

    PubMed

    Shade, Brandon C; Schiavo, Kellie; Rosenthal, Tami; Connelly, James T; Melchior, Richard W

    2016-06-05

    Recent advances in blood pump technology have led to an increased use of centrifugal pumps for prolonged extracorporeal membrane oxygenation (ECMO). Data from the Extracorporeal Life Support Organization confirms that many institutions have converted to centrifugal pumps after prior experience with roller pump technology. Centrifugal pump technology is more compact and may generate less heat and hemolysis than a conventional roller pump. Based on the potential advantages of centrifugal pumps, a decision was made institution-wide to convert to centrifugal pump technology in pediatric implementation of ECMO. Based on limited prior experience with centrifugal pumps, a multidisciplinary approach was used to implement this new technology. The new centrifugal pump (Sorin Revolution, Arvada, CO) was intended for ECMO support in the cardiac intensive care unit (CICU), the pediatric intensive care unit (PICU) and the neonatal intensive care unit (NICU). The perfusion team used their knowledge and expertise with centrifugal pumps to create the necessary teaching tools and interactive training sessions for the technical specialists who consisted primarily of registered nurses and respiratory therapists. The first phase consisted of educating all personnel involved in the care of the ECMO patient, followed by patient implementation in the CICU, followed by the PICU and NICU. The institution-wide conversion took several months to complete and was well received among all disciplines in the CICU and PICU. The NICU personnel did use the centrifugal pump circuit, but decided to revert back to using the roller pump technology. A systematic transition from roller pump to centrifugal pump technology with a multidisciplinary team can ensure a safe and successful implementation. © The Author(s) 2016.

  18. Flow to partially penetrating wells in unconfined heterogeneous aquifers: Mean head and interpretation of pumping tests

    NASA Astrophysics Data System (ADS)

    Dagan, G.; Lessoff, S. C.

    2011-06-01

    A partially penetrating well of length Lw and radius Rw starts to pump at constant discharge Qw at t = 0 from an unconfined aquifer of thickness D. The aquifer is of random and stationary conductivity characterized by KG (geometric mean), σY2 (log conductivity variance), and I and Iv (the horizontal and vertical integral scales). The flow problem is solved under a few simplifying assumptions commonly adopted in the literature for homogeneous media: Rw/Lw ≪ 1, linearization of the free surface condition, and constant drainable porosity n. Additionally, it is assumed that Rw/I < 1 and Lw/Iv ≫ 1 (to simplify the well boundary conditions) and that a first-order approximation in σY2 (extended to finite σY2 on a conjectural basis) is adopted. The solution is obtained for the mean head field and the associated water table equation. The main result of the analysis is that the flow domain can be divided into three zones for : (1) the neighborhood of the well R ≪ I, where = (Qw/LwKA)h0(R, z, tKefuv/nD), with h0 being the zero-order solution pertaining to a homogeneous and isotropic aquifer, KA being the conductivity arithmetic mean, and Kefuv being the effective vertical conductivity in mean uniform flow, (2) an exterior zone R ⪆ I in which ?H? = (Qw/LwKefuh)h0(R?, z, tKefuv/nD), with Kefuh being the horizontal effective conductivity, and (3) an intermediate zone in which the solution requires a few numerical quadratures, not carried out here. The application to pumping tests reveals that identification of the aquifer parameters for homogeneous and anisotropic aquifers by commonly used methods can be applied for the drawdown measured in an observation well of length Low?Iv (to ensure exchange of space and ensemble head averages) in the second zone in order to identify Kefuh, Kefuv, and n. In contrast, the use of the drawdown in the well (first zone) leads to an overestimation of Kefuh by the factor KA/Kefuh.

  19. Common hand sanitizer may distort readings of breathalyzer tests in the absence of acute intoxication.

    PubMed

    Ali, Syed S; Wilson, Michael P; Castillo, Edward M; Witucki, Peter; Simmons, Todd T; Vilke, Gary M

    2013-02-01

    The use of alcohol-based hand sanitizers has recently become widespread. To the authors' knowledge, no previous study has examined whether application of ethanol-based hand sanitizers by the person operating a common breathalyzer machine will affect the accuracy of the readings. This was a prospective study investigating whether the use of hand sanitizer applied according to manufacturer's recommendations (Group I), applied improperly at standard doses (Group II), or applied improperly at high doses (Group III) had an effect on breathalyzer readings of individuals who had not ingested alcohol. The participants of the prospective study were divided into three groups to assess the effect of hand sanitizer on breathalyzer readings. Group I used one pump (1.5 mL) of hand sanitizer (Purell), allowing the hands to dry per manufacturer's recommendations; Group II used one pump (1.5 mL), without allowing the hands to dry; and Group III used two pumps (3 mL), without allowing the hands to dry. Breathalyzer measures for each group are presented as medians with interquartile ranges (IQR) and ranges. Differences between each sequential group (I vs. II and II vs. III) were assessed using a Mann-Whitney U-test (p < 0.05 significant). There were 25 study participants in each group for a total of 75 participants. The initial breathalyzer readings of all study participants were 0.000 g/dL. The median breathalyzer reading was 0.004 g/dL in Group I (IQR = 0.001 to 0.008 g/dL), 0.051 g/dL in Group II (IQR = 0.043 to 0.064 g/dL), and 0.119 g/dL in Group III (IQR = 0.089 to 0.134 g/dL). Measures between each subsequent group were all statistically different (p < 0.001). The use of common alcohol-based hand sanitizer may cause false-positive readings with a standard hospital breathalyzer when the operator uses the hand sanitizer correctly. The breathalyzer readings are further elevated if more sanitizer is used or if it is not allowed to dry appropriately. © 2013 by the Society for

  20. Hands on CERN: A Well-Used Physics Education Project

    ERIC Educational Resources Information Center

    Johansson, K. E.

    2006-01-01

    The "Hands on CERN" education project makes it possible for students and teachers to get close to the forefront of scientific research. The project confronts the students with contemporary physics at its most fundamental level with the help of particle collisions from the DELPHI particle physics experiment at CERN. It now exists in 14 languages…

  1. A nudging data assimilation algorithm for the identification of groundwater pumping

    NASA Astrophysics Data System (ADS)

    Cheng, Wei-Chen; Kendall, Donald R.; Putti, Mario; Yeh, William W.-G.

    2009-08-01

    This study develops a nudging data assimilation algorithm for estimating unknown pumping from private wells in an aquifer system using measured data of hydraulic head. The proposed algorithm treats the unknown pumping as an additional sink term in the governing equation of groundwater flow and provides a consistent physical interpretation for pumping rate identification. The algorithm identifies the unknown pumping and, at the same time, reduces the forecast error in hydraulic heads. We apply the proposed algorithm to the Las Posas Groundwater Basin in southern California. We consider the following three pumping scenarios: constant pumping rates, spatially varying pumping rates, and temporally varying pumping rates. We also study the impact of head measurement errors on the proposed algorithm. In the case study we seek to estimate the six unknown pumping rates from private wells using head measurements from four observation wells. The results show an excellent rate of convergence for pumping estimation. The case study demonstrates the applicability, accuracy, and efficiency of the proposed data assimilation algorithm for the identification of unknown pumping in an aquifer system.

  2. A nudging data assimilation algorithm for the identification of groundwater pumping

    NASA Astrophysics Data System (ADS)

    Cheng, W.; Kendall, D. R.; Putti, M.; Yeh, W. W.

    2008-12-01

    This study develops a nudging data assimilation algorithm for estimating unknown pumping from private wells in an aquifer system using measurement data of hydraulic head. The proposed algorithm treats the unknown pumping as an additional sink term in the governing equation of groundwater flow and provides a consistently physical interpretation for pumping rate identification. The algorithm identifies unknown pumping and, at the same time, reduces the forecast error in hydraulic heads. We apply the proposed algorithm to the Las Posas Groundwater Basin in southern California. We consider the following three pumping scenarios: constant pumping rate, spatially varying pumping rates, and temporally varying pumping rates. We also study the impact of head measurement errors on the proposed algorithm. In the case study, we seek to estimate the six unknown pumping rates from private wells using head measurements from four observation wells. The results show excellent rate of convergence for pumping estimation. The case study demonstrates the applicability, accuracy, and efficiency of the proposed data assimilation algorithm for the identification of unknown pumping in an aquifer system.

  3. Evidence of L-mode electromagnetic wave pumping of ionospheric plasma near geomagnetic zenith

    NASA Astrophysics Data System (ADS)

    Leyser, Thomas B.; James, H. Gordon; Gustavsson, Björn; Rietveld, Michael T.

    2018-02-01

    The response of ionospheric plasma to pumping by powerful HF (high frequency) electromagnetic waves transmitted from the ground into the ionosphere is the strongest in the direction of geomagnetic zenith. We present experimental results from transmitting a left-handed circularly polarized HF beam from the EISCAT (European Incoherent SCATter association) Heating facility in magnetic zenith. The CASSIOPE (CAScade, Smallsat and IOnospheric Polar Explorer) spacecraft in the topside ionosphere above the F-region density peak detected transionospheric pump radiation, although the pump frequency was below the maximum ionospheric plasma frequency. The pump wave is deduced to arrive at CASSIOPE through L-mode propagation and associated double (O to Z, Z to O) conversion in pump-induced radio windows. L-mode propagation allows the pump wave to reach higher plasma densities and higher ionospheric altitudes than O-mode propagation so that a pump wave in the L-mode can facilitate excitation of upper hybrid phenomena localized in density depletions in a larger altitude range. L-mode propagation is therefore suggested to be important in explaining the magnetic zenith effect.

  4. Normetex Pump Alternatives Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clark, Elliot A.

    2013-04-25

    A mainstay pump for tritium systems, the Normetex scroll pump, is currently unavailable because the Normetex company went out of business. This pump was an all-metal scroll pump that served tritium processing facilities very well. Current tritium system operators are evaluating replacement pumps for the Normetex pump and for general used in tritium service. An all-metal equivalent alternative to the Normetex pump has not yet been identified. 1. The ideal replacement tritium pump would be hermetically sealed and contain no polymer components or oils. Polymers and oils degrade over time when they contact ionizing radiation. 2. Halogenated polymers (containing fluorine,more » chlorine, or both) and oils are commonly found in pumps. These materials have many properties that surpass those of hydrocarbon-based polymers and oils, including thermal stability (higher operating temperature) and better chemical resistance. Unfortunately, they are less resistant to degradation from ionizing radiation than hydrocarbon-based materials (in general). 3. Polymers and oils can form gaseous, condensable (HF, TF), liquid, and solid species when exposed to ionizing radiation. For example, halogenated polymers form HF and HCl, which are extremely corrosive upon reaction with water. If a pump containing polymers or oils must be used in a tritium system, the system must be designed to be able to process the unwanted by-products. Design features to mitigate degradation products include filters and chemical or physical traps (eg. cold traps, oil traps). 4. Polymer components can work in tritium systems, but must be replaced regularly. Polymer components performance should be monitored or be regularly tested, and regular replacement of components should be viewed as an expected normal event. A radioactive waste stream must be established to dispose of used polymer components and oil with an approved disposal plan developed based on the facility location and its regulators. Polymers have

  5. Embedding Hands-On Mini Laboratory Experiences in a Core Undergraduate Fluid Mechanics Course: A Pilot Study

    ERIC Educational Resources Information Center

    Han, Duanduan; Ugaz, Victor

    2017-01-01

    Three self-contained mini-labs were integrated into a core undergraduate fluid mechanics course, with the goal of delivering hands-on content in a manner scalable to large class sizes. These mini-labs supported learning objectives involving friction loss in pipes, flow measurement, and centrifugal pump analysis. The hands-on experiments were…

  6. Mass spectrometer vacuum housing and pumping system

    DOEpatents

    Coutts, G.W.; Bushman, J.F.; Alger, T.W.

    1996-07-23

    A vacuum housing and pumping system is described for a portable gas chromatograph/mass spectrometer (GC/MS). The vacuum housing section of the system has minimum weight for portability while designed and constructed to utilize metal gasket sealed stainless steel to be compatible with high vacuum operation. The vacuum pumping section of the system consists of a sorption (getter) pump to remove atmospheric leakage and outgassing contaminants as well as the gas chromatograph carrier gas (hydrogen) and an ion pump to remove the argon from atmospheric leaks. The overall GC/MS system has broad application to contaminants, hazardous materials, illegal drugs, pollution monitoring, etc., as well as for use by chemical weapon treaty verification teams, due to the light weight and portability thereof. 7 figs.

  7. Mass spectrometer vacuum housing and pumping system

    DOEpatents

    Coutts, Gerald W.; Bushman, John F.; Alger, Terry W.

    1996-01-01

    A vacuum housing and pumping system for a portable gas chromatograph/mass spectrometer (GC/MS). The vacuum housing section of the system has minimum weight for portability while designed and constructed to utilize metal gasket sealed stainless steel to be compatible with high vacuum operation. The vacuum pumping section of the system consists of a sorption (getter) pump to remove atmospheric leakage and outgassing contaminants as well as the gas chromatograph carrier gas (hydrogen) and an ion pump to remove the argon from atmospheric leaks. The overall GC/MS system has broad application to contaminants, hazardous materials, illegal drugs, pollution monitoring, etc., as well as for use by chemical weapon treaty verification teams, due to the light weight and portability thereof.

  8. Gas-driven pump for ground-water samples

    USGS Publications Warehouse

    Signor, Donald C.

    1978-01-01

    Observation wells installed for artificial-recharge research and other wells used in different ground-water programs are frequently cased with small-diameter steel pipe. To obtain samples from these small-diameter wells in order to monitor water quality, and to calibrate solute-transport models, a small-diameter pump with unique operating characteristics is required that causes a minimum alternation of samples during field sampling. A small-diameter gas-driven pump was designed and built to obtain water samples from wells of two-inch diameter or larger. The pump is a double-piston type with the following characteristics: (1) The water sample is isolated from the operating gas, (2) no source of electricity is ncessary, (3) operation is continuous, (4) use of compressed gas is efficient, and (5) operation is reliable over extended periods of time. Principles of operation, actual operation techniques, gas-use analyses and operating experience are described. Complete working drawings and a component list are included. Recent modifications and pump construction for high-pressure applications also are described. (Woodard-USGS)

  9. Off-pump myocardial revascularisation in an octogenarian patient with dextrocardia and situs inversus.

    PubMed

    Ennker, I C; Pietrowski, D; Ennker, J

    2006-01-01

    Dextrocardia associated with situs inversus totalis is a rare condition and there are few reports of myocardial revascularisation in such patients. An 82-year-old woman with dextrocardia and situs inversus totalis underwent successful off-pump coronary artery bypass grafting using internal mammary arteries. The operative technique was similar to that of off-pump coronary artery bypass grafting for situs solitus. However, for a right-handed surgeon the operation was easier standing on the left side of the patient.

  10. Method and apparatus for sampling low-yield wells

    DOEpatents

    Last, George V.; Lanigan, David C.

    2003-04-15

    An apparatus and method for collecting a sample from a low-yield well or perched aquifer includes a pump and a controller responsive to water level sensors for filling a sample reservoir. The controller activates the pump to fill the reservoir when the water level in the well reaches a high level as indicated by the sensor. The controller deactivates the pump when the water level reaches a lower level as indicated by the sensors. The pump continuously activates and deactivates the pump until the sample reservoir is filled with a desired volume, as indicated by a reservoir sensor. At the beginning of each activation cycle, the controller optionally can select to purge an initial quantity of water prior to filling the sample reservoir. The reservoir can be substantially devoid of air and the pump is a low volumetric flow rate pump. Both the pump and the reservoir can be located either inside or outside the well.

  11. Representing pump-capacity relations in groundwater simulation models

    USGS Publications Warehouse

    Konikow, Leonard F.

    2010-01-01

    The yield (or discharge) of constant-speed pumps varies with the total dynamic head (or lift) against which the pump is discharging. The variation in yield over the operating range of the pump may be substantial. In groundwater simulations that are used for management evaluations or other purposes, where predictive accuracy depends on the reliability of future discharge estimates, model reliability may be enhanced by including the effects of head-capacity (or pump-capacity) relations on the discharge from the well. A relatively simple algorithm has been incorporated into the widely used MODFLOW groundwater flow model that allows a model user to specify head-capacity curves. The algorithm causes the model to automatically adjust the pumping rate each time step to account for the effect of drawdown in the cell and changing lift, and will shut the pump off if lift exceeds a critical value. The algorithm is available as part of a new multinode well package (MNW2) for MODFLOW.

  12. The healthy heart race: a short-duration, hands-on activity in cardiovascular physiology for museums and science festivals.

    PubMed

    Pressley, Thomas A; Limson, Melvin; Byse, Miranda; Matyas, Marsha Lakes

    2011-09-01

    The "Healthy Heart Race" activity provides a hands-on demonstration of cardiovascular function suitable for lay audiences. It was field tested during the United States of America Science and Engineering Festival held in Washington, DC, in October 2010. The basic equipment for the activity consisted of lengths of plastic tubing, a hand pump, collection containers, clamps, and simulated blood prepared by tinting water with red food coloring. Student participants were first asked to experience the effort required to pump through an unaltered tube. A presenter then applied a strong clamp that pinched each tube downstream from the pump, and students were asked to pump against the increased resistance. The students' observations were then used as the basis for discussions of atherosclerosis and coronary heart disease with the presenters. Distribution of informative postcards during the 2 days of the festival indicated that at least 2,500 students completed the Healthy Heart Race activity. Our experiences to date suggest that the Healthy Heart Race activity can be accomplished effectively in the high-volume, high-distraction environment of a science fair or museum.

  13. Key techniques for space-based solar pumped semiconductor lasers

    NASA Astrophysics Data System (ADS)

    He, Yang; Xiong, Sheng-jun; Liu, Xiao-long; Han, Wei-hua

    2014-12-01

    In space, the absence of atmospheric turbulence, absorption, dispersion and aerosol factors on laser transmission. Therefore, space-based laser has important values in satellite communication, satellite attitude controlling, space debris clearing, and long distance energy transmission, etc. On the other hand, solar energy is a kind of clean and renewable resources, the average intensity of solar irradiation on the earth is 1353W/m2, and it is even higher in space. Therefore, the space-based solar pumped lasers has attracted much research in recent years, most research focuses on solar pumped solid state lasers and solar pumped fiber lasers. The two lasing principle is based on stimulated emission of the rare earth ions such as Nd, Yb, Cr. The rare earth ions absorb light only in narrow bands. This leads to inefficient absorption of the broad-band solar spectrum, and increases the system heating load, which make the system solar to laser power conversion efficiency very low. As a solar pumped semiconductor lasers could absorb all photons with energy greater than the bandgap. Thus, solar pumped semiconductor lasers could have considerably higher efficiencies than other solar pumped lasers. Besides, solar pumped semiconductor lasers has smaller volume chip, simpler structure and better heat dissipation, it can be mounted on a small satellite platform, can compose satellite array, which can greatly improve the output power of the system, and have flexible character. This paper summarizes the research progress of space-based solar pumped semiconductor lasers, analyses of the key technologies based on several application areas, including the processing of semiconductor chip, the design of small and efficient solar condenser, and the cooling system of lasers, etc. We conclude that the solar pumped vertical cavity surface-emitting semiconductor lasers will have a wide application prospects in the space.

  14. 32 CFR Appendix A to Subpart M of... - DPCA Recreational Areas in Training Areas

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... launch adjacent to Officer's Club Beach on American Lake—Beachwood area Cat Lake Picnic and Fishing Area—Training Area 19 Chambers Lake Picnic and Fishing Area—Training Area 12 (See Para 3 below) Fiander lake Picnic and Fishing Area—Training Area 20 Johnson Marsh—Training Area 10 Lewis Lake Picnic and Fishing...

  15. 32 CFR Appendix A to Subpart M of... - DPCA Recreational Areas in Training Areas

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... launch adjacent to Officer's Club Beach on American Lake—Beachwood area Cat Lake Picnic and Fishing Area—Training Area 19 Chambers Lake Picnic and Fishing Area—Training Area 12 (See Para 3 below) Fiander lake Picnic and Fishing Area—Training Area 20 Johnson Marsh—Training Area 10 Lewis Lake Picnic and Fishing...

  16. 32 CFR Appendix A to Subpart M of... - DPCA Recreational Areas in Training Areas

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... launch adjacent to Officer's Club Beach on American Lake—Beachwood area Cat Lake Picnic and Fishing Area—Training Area 19 Chambers Lake Picnic and Fishing Area—Training Area 12 (See Para 3 below) Fiander lake Picnic and Fishing Area—Training Area 20 Johnson Marsh—Training Area 10 Lewis Lake Picnic and Fishing...

  17. Submersible pumping system with heat transfer mechanism

    DOEpatents

    Hunt, Daniel Francis Alan; Prenger, F. Coyne; Hill, Dallas D; Jankowski, Todd Andrew

    2014-04-15

    A submersible pumping system for downhole use in extracting fluids containing hydrocarbons from a well. In one embodiment, the pumping system comprises a rotary induction motor, a motor casing, one or more pump stages, and a cooling system. The rotary induction motor rotates a shaft about a longitudinal axis of rotation. The motor casing houses the rotary induction motor such that the rotary induction motor is held in fluid isolation from the fluid being extracted. The pump stages are attached to the shaft outside of the motor casing, and are configured to impart fluid being extracted from the well with an increased pressure. The cooling system is disposed at least partially within the motor casing, and transfers heat generated by operation of the rotary induction motor out of the motor casing.

  18. Robust technology and system for management of sucker rod pumping units in oil wells

    NASA Astrophysics Data System (ADS)

    Aliev, T. A.; Rzayev, A. H.; Guluyev, G. A.; Alizada, T. A.; Rzayeva, N. E.

    2018-01-01

    We propose a technology for calculating the robust, normalized correlation functions of the signal from the force sensor on the rod string attached to the hanger of the sucker rod pumping unit. The robust normalized correlation functions are used to form sets of informative attribute combinations, each of which corresponds to a technical condition of the sucker rod pumping unit. We demonstrate how these sets can be used to solve identification and management problems in the oil production process in real time using inexpensive controllers. The results obtained from using the system on real objects are also presented in this paper. It was determined that the energy saved and prolonged overhaul period substantially increased the cost-effectiveness.

  19. Modeling the Factors Impacting Pesticide Concentrations in Groundwater Wells.

    PubMed

    Aisopou, Angeliki; Binning, Philip J; Albrechtsen, Hans-Jørgen; Bjerg, Poul L

    2015-01-01

    This study examines the effect of pumping, hydrogeology, and pesticide characteristics on pesticide concentrations in production wells using a reactive transport model in two conceptual hydrogeologic systems; a layered aquifer with and without a stream present. The pumping rate can significantly affect the pesticide breakthrough time and maximum concentration at the well. The effect of the pumping rate on the pesticide concentration depends on the hydrogeology of the aquifer; in a layered aquifer, a high pumping rate resulted in a considerably different breakthrough than a low pumping rate, while in an aquifer with a stream the effect of the pumping rate was insignificant. Pesticide application history and properties have also a great impact on the effect of the pumping rate on the concentration at the well. The findings of the study show that variable pumping rates can generate temporal variability in the concentration at the well, which helps understanding the results of groundwater monitoring programs. The results are used to provide guidance on the design of pumping and regulatory changes for the long-term supply of safe groundwater. The fate of selected pesticides is examined, for example, if the application of bentazone in a region with a layered aquifer stops today, the concentration at the well can continue to increase for 20 years if a low pumping rate is applied. This study concludes that because of the rapid response of the pesticide concentration at the drinking water well due to changes in pumping, wellhead management is important for managing pesticide concentrations. © 2014, National GroundWater Association.

  20. Development and Optimized Design of Propeller Pump System & Structure with VFD in Low-head Pumping Station

    NASA Astrophysics Data System (ADS)

    Rentian, Zhang; Honggeng, Zhu; Arnold, Jaap; Linbi, Yao

    2010-06-01

    Compared with vertical-installed pumps, the propeller (bulb tubular) pump systems can achieve higher hydraulic efficiencies, which are particularly suitable for low-head pumping stations. More than four propeller pumping stations are being, or will be built in the first stage of the S-to-N Water Diversion Project in China, diverting water from Yangtze River to the northern part of China to alleviate water-shortage problems and develop the economy. New structures of propeller pump have been developed for specified pumping stations in Jiangsu and Shandong Provinces respectively and Variable Frequency Drives (VFDs) are used in those pumping stations to regulate operating conditions. Based on the Navier-Stokes equations and the standard k-e turbulent model, numerical simulations of the flow field and performance prediction in the propeller pump system were conducted on the platform of commercial software CFX by using the SIMPLEC algorithm. Through optimal design of bulb dimensions and diffuser channel shape, the hydraulic system efficiency has improved evidently. Furthermore, the structures of propeller pumps have been optimized to for the introduction of conventional as well as permanent magnet motors. In order to improve the hydraulic efficiency of pumping systems, both the pump discharge and the motor diameter were optimized respectively. If a conventional motor is used, the diameter of the pump casing has to be increased to accommodate the motor installed inside. If using a permanent magnet motor, the diameter of motor casing can be decreased effectively without decreasing its output power, thus the cross-sectional area is enlarged and the velocity of flowing water decreased favorably to reduce hydraulic loss of discharge channel and thereby raising the pumping system efficiency. Witness model tests were conducted after numerical optimization on specific propeller pump systems, indicating that the model system hydraulic efficiencies can be improved by 0.5%˜3.7% in

  1. Technical Note: Approximate solution of transient drawdown for constant-flux pumping at a partially penetrating well in a radial two-zone confined aquifer

    NASA Astrophysics Data System (ADS)

    Huang, C.-S.; Yang, S.-Y.; Yeh, H.-D.

    2015-06-01

    An aquifer consisting of a skin zone and a formation zone is considered as a two-zone aquifer. Existing solutions for the problem of constant-flux pumping in a two-zone confined aquifer involve laborious calculation. This study develops a new approximate solution for the problem based on a mathematical model describing steady-state radial and vertical flows in a two-zone aquifer. Hydraulic parameters in these two zones can be different but are assumed homogeneous in each zone. A partially penetrating well may be treated as the Neumann condition with a known flux along the screened part and zero flux along the unscreened part. The aquifer domain is finite with an outer circle boundary treated as the Dirichlet condition. The steady-state drawdown solution of the model is derived by the finite Fourier cosine transform. Then, an approximate transient solution is developed by replacing the radius of the aquifer domain in the steady-state solution with an analytical expression for a dimensionless time-dependent radius of influence. The approximate solution is capable of predicting good temporal drawdown distributions over the whole pumping period except at the early stage. A quantitative criterion for the validity of neglecting the vertical flow due to a partially penetrating well is also provided. Conventional models considering radial flow without the vertical component for the constant-flux pumping have good accuracy if satisfying the criterion.

  2. Valuing technology: A qualitative interview study with physicians about insulin pump therapy for children with type 1 diabetes.

    PubMed

    Shulman, Rayzel; Miller, Fiona A; Daneman, Denis; Guttmann, Astrid

    2016-01-01

    Insulin pumps for children with type 1 diabetes have been broadly adopted despite equivocal evidence about comparative effectiveness. To understand why and inform policy related to public funding for new technologies, we explored how physicians interpret the value of pumps. We conducted open-ended, semi-structured interviews with 16 physicians from a pediatric diabetes network in Ontario, Canada, and analyzed the data using interpretive description. Respondents recognized that pumps fell short of expectations because they required hard work, as well as family and school support. Yet, pumps were valued for their status as new technologies and as a promising step in developing future technology. In addition, they were valued for their role within a therapeutic relationship, given the context of chronic childhood disease. These findings identify the types of beliefs that influence the adoption and diffusion of technologies. Some beliefs bear on hopes for new technology that may inappropriately hasten adoption, creating excess cost with little benefit. On the other hand, some beliefs identify potential benefits that are not captured in effectiveness studies, but may warrant consideration in resource allocation decisions. Still others suggest the need for remediation, such as those bearing on disparity in pump use by socioeconomic status. Understanding how technologies are valued can help stakeholders decide how to address such beliefs and expectations in funding decisions and implementation protocols. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Lunar Base Heat Pump

    NASA Technical Reports Server (NTRS)

    Walker, D.; Fischbach, D.; Tetreault, R.

    1996-01-01

    The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.

  4. Acoustic Pump

    NASA Technical Reports Server (NTRS)

    Heyman, Joseph S.

    1993-01-01

    Pump uses acoustic-radiation forces. Momentum transferred from sound waves to sound-propagating material in way resulting in net pumping action on material. Acoustic pump is solid-state pump. Requires no moving parts, entirely miniaturized, and does not invade pumped environment. Silent, with no conventional vibration. Used as pump for liquid, suspension, gas, or any other medium interacting with radiation pressure. Also used where solid-state pump needed for reliability and controllability. In microgravity environment, device offers unusual control for low flow rates. For medical or other applications in which contamination cannot be allowed, offers noninvasive pumping force.

  5. PUMP CONSTRUCTION

    DOEpatents

    Strickland, G.; Horn, F.L.; White, H.T.

    1960-09-27

    A pump which utilizes the fluid being pumped through it as its lubricating fluid is described. This is achieved by means of an improved bearing construction in a pump of the enclosed or canned rotor type. At the outlet end of the pump, adjacent to an impeller mechanism, there is a bypass which conveys some of the pumped fluid to a chamber at the inlet end of the pump. After this chamber becomes full, the pumped fluid passes through fixed orifices in the top of the chamber and exerts a thrust on the inlet end of the pump rotor. Lubrication of the rotor shaft is accomplished by passing the pumped fluid through a bypass at the outlet end of the rotor shaft. This bypass conveys Pumped fluid to a cooling means and then to grooves on the surface of the rotor shait, thus lubricating the shaft.

  6. Identification of pumping influences in long-term water level fluctuations.

    PubMed

    Harp, Dylan R; Vesselinov, Velimir V

    2011-01-01

    Identification of the pumping influences at monitoring wells caused by spatially and temporally variable water supply pumping can be a challenging, yet an important hydrogeological task. The information that can be obtained can be critical for conceptualization of the hydrogeological conditions and indications of the zone of influence of the individual pumping wells. However, the pumping influences are often intermittent and small in magnitude with variable production rates from multiple pumping wells. While these difficulties may support an inclination to abandon the existing dataset and conduct a dedicated cross-hole pumping test, that option can be challenging and expensive to coordinate and execute. This paper presents a method that utilizes a simple analytical modeling approach for analysis of a long-term water level record utilizing an inverse modeling approach. The methodology allows the identification of pumping wells influencing the water level fluctuations. Thus, the analysis provides an efficient and cost-effective alternative to designed and coordinated cross-hole pumping tests. We apply this method on a dataset from the Los Alamos National Laboratory site. Our analysis also provides (1) an evaluation of the information content of the transient water level data; (2) indications of potential structures of the aquifer heterogeneity inhibiting or promoting pressure propagation; and (3) guidance for the development of more complicated models requiring detailed specification of the aquifer heterogeneity. Copyright © 2010 The Author(s). Journal compilation © 2010 National Ground Water Association.

  7. Modeling the potential impact of seasonal and inactive multi-aquifer wells on contaminant movement to public water-supply wells

    USGS Publications Warehouse

    Johnson, R.L.; Clark, B.R.; Landon, M.K.; Kauffman, L.J.; Eberts, S.M.

    2011-01-01

    Wells screened across multiple aquifers can provide pathways for the movement of surprisingly large volumes of groundwater to confined aquifers used for public water supply (PWS). Using a simple numerical model, we examine the impact of several pumping scenarios on leakage from an unconfined aquifer to a confined aquifer and conclude that a single inactive multi-aquifer well can contribute nearly 10% of total PWS well flow over a wide range of pumping rates. This leakage can occur even when the multi-aquifer well is more than a kilometer from the PWS well. The contribution from multi-aquifer wells may be greater under conditions where seasonal pumping (e.g., irrigation) creates large, widespread downward hydraulic gradients between aquifers. Under those conditions, water can continue to leak down a multi-aquifer well from an unconfined aquifer to a confined aquifer even when those multi-aquifer wells are actively pumped. An important implication is that, if an unconfined aquifer is contaminated, multi-aquifer wells can increase the vulnerability of a confined-aquifer PWS well.

  8. LMFBR with booster pump in pumping loop

    DOEpatents

    Rubinstein, H.J.

    1975-10-14

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation.

  9. Less and less-influence of volume on hand coverage and bactericidal efficacy in hand disinfection.

    PubMed

    Kampf, Günter; Ruselack, Sigunde; Eggerstedt, Sven; Nowak, Nicolas; Bashir, Muhammad

    2013-10-10

    Some manufacturers recommend using 1.1 mL per application of alcohol-based handrubs for effective hand disinfection. However, whether this volume is sufficient to cover both hands, as recommended by the World Health Organization, and fulfills current efficacy standards is unknown. This study aimed to determine hand coverage for three handrubs (two gels based on 70% v/v and 85% w/w ethanol and a foam based on 70% v/v ethanol) applied at various volumes. Products were tested at product volumes of 1.1 mL, 2 mL, 2.4 mL as well as 1 and 2 pump dispenser pushes; the foam product was tested in addition at foam volumes of 1.1 mL, 2 mL, and 2.4 mL. Products were supplemented with a fluorescent dye and 15 participants applied products using responsible application techniques without any specific steps but the aim of completely covering both hands. Coverage quality was determined under ultraviolet light by two blinded investigators. Efficacy of the three handrubs was determined according to ASTM E 1174-06 and ASTM E 2755-10. For each experiment, the hands of 12 participants were contaminated with Serratia marcescens and the products applied as recommended (1.1 mL for 70% v/v ethanol products; 2 mL for the 85% w/w ethanol product). Log10-reduction was calculated. Volumes < 2 mL yielded high rates of incomplete coverage (67%-87%) whereas volumes ≥ 2 mL gave lower rates (13%-53%). Differences in coverage were significant between the five volumes tested for all handrubs (p < 0.001; two-way ANOVA) but not between the three handrubs themselves (p = 0.796). Application of 1.1 mL of 70% v/v ethanol rubs reduced contamination by 1.85 log10 or 1.60 log10 (ASTM E 1174-06); this failed the US FDA efficacy requirement of at least 2 log10. Application of 2 mL of the 85% w/w ethanol rub reduced contamination by 2.06 log10 (ASTM E 1174-06), fulfilling the US FDA efficacy requirement. Similar results were obtained according to ASTM E 2755-10. Our data indicated that

  10. Less and less–influence of volume on hand coverage and bactericidal efficacy in hand disinfection

    PubMed Central

    2013-01-01

    Background Some manufacturers recommend using 1.1 mL per application of alcohol-based handrubs for effective hand disinfection. However, whether this volume is sufficient to cover both hands, as recommended by the World Health Organization, and fulfills current efficacy standards is unknown. This study aimed to determine hand coverage for three handrubs (two gels based on 70% v/v and 85% w/w ethanol and a foam based on 70% v/v ethanol) applied at various volumes. Methods Products were tested at product volumes of 1.1 mL, 2 mL, 2.4 mL as well as 1 and 2 pump dispenser pushes; the foam product was tested in addition at foam volumes of 1.1 mL, 2 mL, and 2.4 mL. Products were supplemented with a fluorescent dye and 15 participants applied products using responsible application techniques without any specific steps but the aim of completely covering both hands. Coverage quality was determined under ultraviolet light by two blinded investigators. Efficacy of the three handrubs was determined according to ASTM E 1174-06 and ASTM E 2755-10. For each experiment, the hands of 12 participants were contaminated with Serratia marcescens and the products applied as recommended (1.1 mL for 70% v/v ethanol products; 2 mL for the 85% w/w ethanol product). Log10-reduction was calculated. Results Volumes < 2 mL yielded high rates of incomplete coverage (67%–87%) whereas volumes ≥ 2 mL gave lower rates (13%–53%). Differences in coverage were significant between the five volumes tested for all handrubs (p < 0.001; two-way ANOVA) but not between the three handrubs themselves (p = 0.796). Application of 1.1 mL of 70% v/v ethanol rubs reduced contamination by 1.85 log10 or 1.60 log10 (ASTM E 1174-06); this failed the US FDA efficacy requirement of at least 2 log10. Application of 2 mL of the 85% w/w ethanol rub reduced contamination by 2.06 log10 (ASTM E 1174-06), fulfilling the US FDA efficacy requirement. Similar results were obtained according to ASTM E 2755

  11. Steam ejector as an industrial heat pump

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arnold, H.G.; Huntley, W.R.; Perez-Blanco, H.

    1982-01-01

    The steam ejector is analyzed for use in industrial heat recovery applications and compared to mechanical compressor heat pumps. An estimated ejector performance was analyzed using methods based on conservation of mass, momentum, and energy; using steam properties to account for continuity; and using appropriate efficiencies for the nozzle and diffuse performance within the ejector. A potential heat pump application at a paper plant in which waste water was available in a hot well downstream of the paper machine was used to describe use of the stream ejector. Both mechanical compression and jet ejector heat pumps were evaluated for recompressionmore » of flashed steam from the hot well. It is noted that another possible application of vapor recompression heat pumps is the recovery of waste heat from large facilities such as the gaseous diffusion plants. The economics of recovering waste heat in similar applications is analyzed. (MCW)« less

  12. 14. GENE PUMPING STATION CONTROL ROOM AS SEEN FROM MAIN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. GENE PUMPING STATION CONTROL ROOM AS SEEN FROM MAIN STATION MANAGER'S CONTROL DESK. ELECTRICAL CONTROL INDICATORS AND CONTROLS FOR REGULATING ELECTRICITY INTO PLANT AS WELL AS SYNCHRONIZING STARTUP OF PUMPS. - Gene Pump Plant, South of Gene Wash Reservoir, 2 miles west of Whitsett Pump Plant, Parker Dam, San Bernardino County, CA

  13. Representing pump-capacity relations in groundwater simulati on models

    USGS Publications Warehouse

    Konikow, Leonard F.

    2010-01-01

    The yield (or discharge) of constant-speed pumps varies with the total dynamic head (or lift) against which the pump is discharging. The variation in yield over the operating range of the pump may be substantial. In groundwater simulations that are used for management evaluations or other purposes, where predictive accuracy depends on the reliability of future discharge estimates, model reliability may be enhanced by including the effects of head-capacity (or pump-capacity) relations on the discharge from the well. A relatively simple algorithm has been incorporated into the widely used MODFLOW groundwater flow model that allows a model user to specify head-capacity curves. The algorithm causes the model to automatically adjust the pumping rate each time step to account for the effect of drawdown in the cell and changing lift, and will shut the pump off if lift exceeds a critical value. The algorithm is available as part of a new multinode well package (MNW2) for MODFLOW. ?? 2009 National Ground Water Association.

  14. Fano resonance in the nonadiabatically pumped shot noise of a time-dependent quantum well in a two-dimensional electron gas and graphene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Rui, E-mail: rzhu@scut.edu.cn; Dai, Jiao-Hua; Guo, Yong

    Interference between different quantum paths can generate Fano resonance. One of the examples is transport through a quasibound state driven by a time-dependent scattering potential. Previously it is found that Fano resonance occurs as a result of energy matching in one-dimensional systems. In this work, we demonstrate that when transverse motion is present, Fano resonance occurs precisely at the wavevector matching situation. Using the Floquet scattering theory, we considered the transport properties of a nonadiabatic time-dependent well both in a two-dimensional electron gas and monolayer graphene structure. Dispersion of the quasibound state of a static quantum well is obtained withmore » transverse motion present. We found that Fano resonance occurs when the wavevector in the transport direction of one of the Floquet sidebands is exactly identical to that of the quasibound state in the well at equilibrium and follows the dispersion pattern of the latter. To observe the Fano resonance phenomenon in the transmission spectrum, we also considered the pumped shot noise properties when time and spatial symmetry secures vanishing current in the considered configuration. Prominent Fano resonance is found in the differential pumped shot noise with respect to the reservoir Fermi energy.« less

  15. Skin reactions related to hand hygiene and selection of hand hygiene products.

    PubMed

    Larson, Elaine; Girard, Raphaelle; Pessoa-Silva, Carmem Lucia; Boyce, John; Donaldson, Liam; Pittet, Didier

    2006-12-01

    In October 2004, The World Health Organization (WHO) launched the World Alliance for Patient Safety. Within the alliance, the first priority of the Global Patient Safety Challenge is to reduce health care-associated infection. A key action within the challenge is to promote hand hygiene in health care globally as well as at the country level through the campaign "Clean Care is Safer Care." As a result, the WHO is developing Guidelines on Hand Hygiene in Health Care, designed to be applicable throughout the world. This paper summarizes one component of the global WHO guidelines related to the impact of hand hygiene on the skin of health care personnel, including a discussion of types of skin reactions associated with hand hygiene, methods to reduce adverse reactions, and factors to consider when selecting hand hygiene products. Health care professionals have a higher prevalence of skin irritation than seen in the general population because of the necessity for frequent hand hygiene during patient care. Ways to minimize adverse effects of hand hygiene include selecting less irritating products, using skin moisturizers, and modifying certain hand hygiene practices such as unnecessary washing. Institutions need to consider several factors when selecting hand hygiene products: dermal tolerance and aesthetic preferences of users as well as practical considerations such as convenience, storage, and costs.

  16. In-well time-of-travel approach to evaluate optimal purge duration during low-flow sampling of monitoring wells

    USGS Publications Warehouse

    Harte, Philip T.

    2017-01-01

    A common assumption with groundwater sampling is that low (<0.5 L/min) pumping rates during well purging and sampling captures primarily lateral flow from the formation through the well-screened interval at a depth coincident with the pump intake. However, if the intake is adjacent to a low hydraulic conductivity part of the screened formation, this scenario will induce vertical groundwater flow to the pump intake from parts of the screened interval with high hydraulic conductivity. Because less formation water will initially be captured during pumping, a substantial volume of water already in the well (preexisting screen water or screen storage) will be captured during this initial time until inflow from the high hydraulic conductivity part of the screened formation can travel vertically in the well to the pump intake. Therefore, the length of the time needed for adequate purging prior to sample collection (called optimal purge duration) is controlled by the in-well, vertical travel times. A preliminary, simple analytical model was used to provide information on the relation between purge duration and capture of formation water for different gross levels of heterogeneity (contrast between low and high hydraulic conductivity layers). The model was then used to compare these time–volume relations to purge data (pumping rates and drawdown) collected at several representative monitoring wells from multiple sites. Results showed that computation of time-dependent capture of formation water (as opposed to capture of preexisting screen water), which were based on vertical travel times in the well, compares favorably with the time required to achieve field parameter stabilization. If field parameter stabilization is an indicator of arrival time of formation water, which has been postulated, then in-well, vertical flow may be an important factor at wells where low-flow sampling is the sample method of choice.

  17. Relations between well-field pumping and induced canal leakage in east-central Miami-Dade County, Florida, 2010-2011

    USGS Publications Warehouse

    Nemec, Katherine; Antolino, Dominick J.; Turtora, Michael; Adam Foster,

    2015-08-26

    Results from the groundwater model and the stable isotope data analysis indicate the importance of considering geologic heterogeneity when investigating the relations between pumping and canal leakage, not only at this site, but also at other sites with similar heterogeneous geology. The model results were consistently sensitive to the hydrogeologic framework and changes in hydraulic conductivities. The model and the isotope data indicate that the majority of the groundwater/surface-water interactions occurred within the shallow flow zone. A relatively lower-permeability geologic layer occurring between the shallowest and deep preferential flow zones lessens the interactions between the production wells and the canal.

  18. [Critical infusion incident caused by incorrect use of a patient-controlled analgesia pump].

    PubMed

    Steffen, M; von Hintzenstern, U; Obermayer, A

    2002-01-01

    We report on the case of a 17-year-old male patient who received a PCA pump after nephrectomy for postoperative analgesia. The syringe of the PCA pump was filled with 50 mg morphine and positioned about 25 cm above the heart. Since the piston of the syringe was not bolted while the pump was switched off, an unnoticed accidental evacuation of the whole content of the syringe into the intravenous line of the patient occurred because of gravity. This problem exists not only with PCA pumps, but can happen with syringe pumps in general. The incident, which can only be explained by strongly reduced venous pressure, was detected by chance. No harm resulted for the patient, but under different conditions it could have been lethal. This critical incident was caused by various factors: incorrect application in combination with insufficient experience or training, stress, inadequate handing-over of the patient and a lack of arrangements and instructions for procedures in routine situations. Suggestions for preventing such dangerous critical incidents are made and discussed. In particular, an algorithm for the correct procedure when inserting or changing the syringe of a syringe pump is presented.

  19. Self-potential response to periodic pumping test: a numerical study

    NASA Astrophysics Data System (ADS)

    Konosavsky, Pavel; Maineult, Alexis; Narbut, Mikhail; Titov, Konstantin

    2017-09-01

    We numerically model self-potential responses associated with periodic pumping test experiments by sequential calculation of the hydraulic response and the coupled electrical potential. We assume the pumping test experiments with a fully saturated confined aquifer. Application of different excitation functions leads to quasi-linear trends in electrical records whose direction and intensity depend on the form of the excitation function. The hydraulic response is phase shifted compared to the excitation function; the phase shift increases quasi-linearly with the distance from the pumping well. For the electrical signals, we investigated separately the cases of conducting and insulating casings of the pumping well. For the conducting casing the electrical signals are larger in magnitude than that for the insulating casing; they reproduce the drawdown signals in the pumping well at any distance from the well and exhibit any phase shift with the increased distance. For the insulating casing, the electrical signals are phase shifted and their shape depends on the distance from the pumping well. Three characteristic regimes were found for the phase shift, φ, with the increased distance and for various hydraulic diffusivity values. At small distances φ increases quasi-linearly; at intermediate distances φ attends the value of π/2 and stay about this value (for relatively small diffusivity values); and at large distances φ attends the value of π and, stay about this value at larger distances. This behaviour of the electrical signals can be explained by two electrical sources of reverse polarity. They are (i) linear, time independent, and located at the pumping interval of the well; and (ii) volumetric, time dependent, with maximum value located in the aquifer at the distance corresponding to maximum variation of the hydraulic head magnitude with time. We also model the variation of the amplitude and phase of the hydraulic and electrical signals with increased

  20. Targeting efflux pumps to overcome antifungal drug resistance

    PubMed Central

    Holmes, Ann R; Cardno, Tony S; Strouse, J Jacob; Ivnitski-Steele, Irena; Keniya, Mikhail V; Lackovic, Kurt; Monk, Brian C; Sklar, Larry A; Cannon, Richard D

    2016-01-01

    Resistance to antifungal drugs is an increasingly significant clinical problem. The most common antifungal resistance encountered is efflux pump-mediated resistance of Candida species to azole drugs. One approach to overcome this resistance is to inhibit the pumps and chemosensitize resistant strains to azole drugs. Drug discovery targeting fungal efflux pumps could thus result in the development of azole-enhancing combination therapy. Heterologous expression of fungal efflux pumps in Saccharomyces cerevisiae provides a versatile system for screening for pump inhibitors. Fungal efflux pumps transport a range of xenobiotics including fluorescent compounds. This enables the use of fluorescence-based detection, as well as growth inhibition assays, in screens to discover compounds targeting efflux-mediated antifungal drug resistance. A variety of medium- and high-throughput screens have been used to identify a number of chemical entities that inhibit fungal efflux pumps. PMID:27463566

  1. Continuously pumping and reactivating gas pump

    DOEpatents

    Batzer, T.H.; Call, W.R.

    Apparatus for continuous pumping using cycling cryopumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels that alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independant pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped.

  2. Continuously pumping and reactivating gas pump

    DOEpatents

    Batzer, Thomas H.; Call, Wayne R.

    1984-01-01

    Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped.

  3. Mechanical pumps for superfluid helium transfer in space

    NASA Technical Reports Server (NTRS)

    Izenson, M. G.; Swift, W. L.

    1988-01-01

    Two alternate mechanical pump concepts have been identified for the transfer of superfluid helium in space. Both pumps provide flow at sufficient head and have operating characteristics suitable for the Space Infrared Telescope Facility (SIRTF) refill mission. One pump operates at a relatively low speed and utilizes mechanical roller bearings, while the other operates at a higher rotational speed using either electromagnetic or tilting pad gas-dynamic bearings. The use of gas bearings requires transfer of normal helium so that the gas pressure within the pump casing is high enough to operate the bearings. The operating characteristics of both pumps are predicted, the dimensions are estimated and major technology issues are identified. The major issues for each pump design are cavitation performance and bearing development. Roller bearings require quantified reliability for operation in space while electromagnetic bearings require basic development as well as a complex control system. The low speed pump has significantly poorer hydraulic efficiency than the high speed pump.

  4. Entropy, pricing and productivity of pumped-storage

    NASA Astrophysics Data System (ADS)

    Karakatsanis, Georgios; Tyralis, Hristos; Tzouka, Katerina

    2016-04-01

    Pumped-storage constitutes today a mature method of bulk electricity storage in the form of hydropower. This bulk electricity storability upgrades the economic value of hydropower as it may mitigate -or even neutralize- stochastic effects deriving from various geophysical and socioeconomic factors, which produce numerous load balance inefficiencies due to increased uncertainty. Pumped-storage further holds a key role for unifying intermittent renewable (i.e. wind, solar) units with controllable non-renewable (i.e. nuclear, coal) fuel electricity generation plants into integrated energy systems. We develop a set of indicators for the measurement of performance of pumped-storage, in terms of the latter's energy and financial contribution to the energy system. More specifically, we use the concept of entropy in order to examine: (1) the statistical features -and correlations- of the energy system's intermittent components and (2) the statistical features of electricity demand prediction deviations. In this way, the macroeconomics of pumped-storage emerges naturally from its statistical features (Karakatsanis et al. 2014). In addition, these findings are combined to actual daily loads. Hence, not only the amount of energy harvested from the pumped-storage component is expected to be important, but the harvesting time as well, as the intraday price of electricity varies significantly. Additionally, the structure of the pumped-storage market proves to be a significant factor as well for the system's energy and financial performance (Paine et al. 2014). According to the above, we aim at postulating a set of general rules on the productivity of pumped-storage for (integrated) energy systems. Keywords: pumped-storage, storability, economic value of hydropower, stochastic effects, uncertainty, energy systems, entropy, intraday electricity price, productivity References 1. Karakatsanis, Georgios et al. (2014), Entropy, pricing and macroeconomics of pumped-storage systems

  5. [Does the hand solely belong in the hands of a qualified hand surgeon?

    PubMed

    Güven, Asim; Kols, Kerstin; Fischer, Klaus; Schönberger, Michael; Allert, Sixtus

    2017-09-01

    Background In Germany, Hand Surgery is an additional qualification that can only be obtained by a three-year training after a completed residency in General Surgery, Plastic Surgery or Trauma and Orthopaedic Surgery. Nevertheless, injuries and diseases of the hand are also treated by physicians without this particular qualification. It is questionable whether these treatments more often lead to medical malpractice. Material and Methods 376 charges of medical malpractice in surgical treatments of the hand and forearm that were closed in 2014 and 2015 were collected by the Arbitration Board for Medical Liability Issues of the Medical Association of North Germany.Cases with proven medical malpractice were classified by the qualification of the physician in charge and analysed. A statistical analysis was performed with the use of the program SPSS (IBM). Results Medical malpractice was proven in 42 of 113 cases with an attending physician who held the additional qualification for Hand Surgery (37.2 %). For physicians without this qualification, the figures were 79 out of 155 (51.0 %) in the group of trauma and orthopaedic surgeons and 54 out of 108 (50.0 %) in the group of general surgeons. The differences between the hand surgeons and the trauma and orthopaedic surgeons (p = 0.017) and between hand surgeons and general surgeons were significant (p = 0.037). Conclusions It was shown that physicians with an additional qualification in hand surgery had signifcantly fewer proven medical malpratice cases than physicians without this qualification. The following trends were observed in the cases of the physicians without the additional qualification in hand surgery: underestimation of the severity of trauma to soft tissues and infections of the hand, errors in the surgical examination of the hand, including functional tests of tendons and nerves, as well as in diagnostic findings after X-ray studies of the hand. Georg Thieme Verlag KG Stuttgart · New York.

  6. CFD research on runaway transient of pumped storage power station caused by pumping power failure

    NASA Astrophysics Data System (ADS)

    Zhang, L. G.; Zhou, D. Q.

    2013-12-01

    To study runaway transient of pumped storage power station caused by pumping power failure, three dimensional unsteady numerical simulations were executed on geometrical model of the whole flow system. Through numerical calculation, the changeable flow configuration and variation law of some parameters such as unit rotate speed,flow rate and static pressure of measurement points were obtained and compared with experimental data. Numerical results show that runaway speed agrees well with experimental date and its error was 3.7%. The unit undergoes pump condition, brake condition, turbine condition and runaway condition with flow characteristic changing violently. In runaway condition, static pressure in passage pulses very strongly which frequency is related to runaway speed.

  7. Direct solar-pumped iodine laser amplifier

    NASA Technical Reports Server (NTRS)

    Han, Kwang S.; Hwang, In H.; Stock, Larry V.

    1988-01-01

    A XeCl laser which was developed earlier for an iodine laser oscillator was modified in order to increase the output pulse energy of XeCl laser so that the iodine laser output energy could be increased. The electrical circuit of the XeCl laser was changed from a simple capacitor discharge circuit of the XeCl laser to a Marx system. Because of this improvement the output energy from the XeCl laser was increased from 60 mj to 80 mj. Subsequently, iodine laser output energy was increased from 100 mj to 3 mj. On the other hand, the energy storage capability and amplification characteristics of the Vortek solar simulator-pumped amplifier was calculated expecting the calculated amplification factor is about 2 and the energy extraction efficiency is 26 percent due to the very low input energy density to the amplifier. As a result of an improved kinetic modeling for the iodine solar simulator pumped power amplifier, it is found that the I-2 along the axis of the tube affects seriously the gain profile. For the gas i-C3F7I at the higher pressures, the gain will decrease due to the I-2 as the pumping intensity increases, and at these higher pressures an increase in flow velocity will increase the gain.

  8. Pulsations Induced by Vibrations in Aircraft Engine Two-Stage Pump

    NASA Astrophysics Data System (ADS)

    Gafurov, S. A.; Salmina, V. A.; Handroos, H.

    2018-01-01

    This paper describes a phenomenon of induced pressure pulsations inside a two-stage aircraft engine pump. A considered pumps consists of a screw-centrifugal and gear stages. The paper describes the cause of two-stage pump elements loading. A number of hypothesis of pressure pulsations generation inside a pump were considered. The main focus in this consideration is made on phenomena that are not related to pump mode of operation. Provided analysis has shown that pump vibrations as well as pump elements self-oscillations are the main causes that lead to trailing vortices generation. Analysis was conducted by means FEM and CFD simulations as well by means of experimental investigations to obtain natural frequencies and flow structure inside a screw-centrifugal stage. To perform accurate simulations adequate boundary conditions were considered. Cavitation and turbulence phenomena have been also taken into account. Obtained results have shown generated trailing vortices lead to high-frequency loading of the impeller of screw-centrifugal stage and can be a cause of the bearing damage.

  9. [The development tendencies of infusion pumps/syringe pumps].

    PubMed

    Zhang, Peng; Wang, Shu-Yi; Yu, Chuan-Yi; Zhang, Min-Yan

    2009-07-01

    Through the investigation about the current infusion pumps, the development tendencies of the next generation infusion pumps/Syringe Pumps with regarding to human-factors, practicality and application under MRI (Magnetic resonance imaging) were put forward.

  10. Foam soap is not as effective as liquid soap in eliminating hand microbial flora.

    PubMed

    Dixon, Nicolette; Morgan, Margie; Equils, Ozlem

    2017-07-01

    Foam soaps are aerosolized liquid soaps dispensed through a special pump mechanism. Currently there are no studies comparing liquid soap with foam soap in regard to efficacy of reducing hand microbial burden. In 3 separate experiments and with 2 different brands of foam soap, it was observed that nonantimicrobial foam soap was not as effective in reducing hand bacterial load as the liquid soap. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  11. Vibration analysis of large centrifugal pump rotors

    NASA Astrophysics Data System (ADS)

    Y Zhao, W.; Ge, J. G.; Ma, D.; Li, C. M.; Bao, S. B.

    2013-12-01

    Through the critical speed of centrifugal pumps, internal flow field and the force of the impeller, we analyze centrifugal pump vibration. Using finite element analysis software ANSYS to calculate the natural frequency of the rotor system and the critical speed; with the help of the Fluent software to simulate pump internal flow field, we conclude that speed increase will not cause intense vibration of the fluid in the pump. Using unsteady numerical simulation we discovered that in an impeller suffering transient radial force cyclical change periodically, as well as the frequency size determined by the product of the impeller speed and number of blades, resonance phenomena should make impeller to transient radial force frequency. If wanting to avoid pump resonance when it is running away, the transient radial force frequency should avoid the frequency range which can cause resonance.

  12. Quantum behaviour of pumped and damped triangular Bose-Hubbard systems

    NASA Astrophysics Data System (ADS)

    Chianca, C. V.; Olsen, M. K.

    2017-12-01

    We propose and analyse analogs of optical cavities for atoms using three-well Bose-Hubbard models with pumping and losses. We consider triangular configurations. With one well pumped and one damped, we find that both the mean-field dynamics and the quantum statistics show a quantitative dependence on the choice of damped well. The systems we analyse remain far from equilibrium, preserving good coherence between the wells in the steady-state. We find quadrature squeezing and mode entanglement for some parameter regimes and demonstrate that the trimer with pumping and damping at the same well is the stronger option for producing non-classical states. Due to recent experimental advances, it should be possible to demonstrate the effects we investigate and predict.

  13. Pump tank divider plate for sump suction sodium pumps

    DOEpatents

    George, John A.; Nixon, Donald R.

    1977-01-01

    A circular plate extends across the diameter of "sump suction" pump, with a close clearance between the edge of the plate and the wall of the pump tank. The plate is located above the pump impeller, inlet and outlet flow nozzles but below the sodium free surface and effectively divides the pump tank into two separate chambers. On change of pump speed, the close fitting flow restriction plate limits the rate of flow into or out of the upper chamber, thereby minimizing the rate of level change in the tank and permitting time for the pump cover gas pressure to be varied to maintain an essentially constant level.

  14. 78 FR 59475 - Architectural Barriers Act Accessibility Guidelines; Outdoor Developed Areas

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-26

    ... following outdoor constructed features provided at these facilities: Picnic tables, fire rings, grills... requirements for picnic tables, fire rings, grills, fireplaces, wood stoves, trash and recycling receptacles... have required 50 percent of picnic tables, fire rings, grills, and benches to comply with the...

  15. Nuclear pumped laser II

    NASA Technical Reports Server (NTRS)

    Deyoung, R. J.; Lee, J. H.; Pinkston, W. T.

    1977-01-01

    The first direct nuclear pumped laser using the He-2-(n,p) H-3 reaction is reported. Lasing took place on the 1.79 microns Ar I transition in a mixture of He-3-Ar at approximately 600 Torr total pressure. It was found that the electrically pulsed afterglow He-Ar laser had the same concentration profile as the nuclear pumped laser. As a result, nuclear lasing was also achieved in He-3-Xe (2.027 micron) and He-3-Kr (2.52 micron). Scaling of laser output with both thermal flux and total pressure as well as minority concentration has been completed. A peak output (He-3-Ar) of 3.7 watts has been achieved at a total pressure of 4 atm. Direct nuclear pumping of He-3-Ne has also been achieved. Nuclear pumping of a He-3-NF3 mixture was attempted, lasing in FI at approximately 7000 A, without success, although the potential lasing transitions appeared in spontaneous emission. Both NF3 and 238UF6 appear to quench spontaneous emission when they constitute more than 1% of the gas mixture.

  16. Alternative backing up pump for turbomolecular pumps

    DOEpatents

    Myneni, Ganapati Rao

    2003-04-22

    As an alternative to the use of a mechanical backing pump in the application of wide range turbomolecular pumps in ultra-high and extra high vacuum applications, palladium oxide is used to convert hydrogen present in the evacuation stream and related volumes to water with the water then being cryo-pumped to a low pressure of below about 1.e.sup.-3 Torr at 150.degree. K. Cryo-pumping is achieved using a low cost Kleemenco cycle cryocooler, a somewhat more expensive thermoelectric cooler, a Venturi cooler or a similar device to achieve the required minimization of hydrogen partial pressure.

  17. Liquid metal pump

    DOEpatents

    Pennell, William E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair.

  18. Large-Scale Pumping Test Recommendations for the 200-ZP-1 Operable Unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spane, Frank A.

    2010-09-08

    CH2M Hill Plateau Remediation Company (CHPRC) is currently assessing aquifer characterization needs to optimize pump-and-treat remedial strategies (e.g., extraction well pumping rates, pumping schedule/design) in the 200-ZP-1 operable unit (OU), and in particular for the immediate area of the 241 TX-TY Tank Farm. Specifically, CHPRC is focusing on hydrologic characterization opportunities that may be available for newly constructed and planned ZP-1 extraction wells. These new extraction wells will be used to further refine the 3-dimensional subsurface contaminant distribution within this area and will be used in concert with other existing pump-and-treat wells to remediate the existing carbon tetrachloride contaminant plume.more » Currently, 14 extraction wells are actively used in the Interim Record of Decision ZP-1 pump-and-treat system for the purpose of remediating the existing carbon tetrachloride contamination in groundwater within this general area. As many as 20 new extraction wells and 17 injection wells may be installed to support final pump-and-treat operations within the OU area. It should be noted that although the report specifically refers to the 200-ZP-1 OU, the large-scale test recommendations are also applicable to the adjacent 200-UP-1 OU area. This is because of the similar hydrogeologic conditions exhibited within these two adjoining OU locations.« less

  19. Optically pumped lasing in a rolled-up dot-in-a-well (DWELL) microtube via the support of Au pad

    NASA Astrophysics Data System (ADS)

    Chai, Zhaoer; Wang, Qi; Cao, Jiawei; Mao, Guoming; Liu, Hao; Ren, Xiaomin; Maleev, Nikolai A.; Vasil'ev, Alexey P.; Zhukov, Alexey E.; Ustinov, Victor M.

    2018-02-01

    We report the observation of optically pumped continuous wave lasing in a self-rolled-up InGaAs/GaAs quantum dot microtube at room temperature. Single layer of InAs quantum dots ( 2.6 ML coverage) in a GaAs well sandwiched by two AlGaAs barriers are incorporated into the tube wall as the gain media. As-fabricated microtube is supported by a 300-nm-thick Au pad, aiming to separate the tube from GaAs substrate and thus to decrease the substrate loss, which finally enables lasing with ultralow threshold power ( 4 µW) from an microtube ring resonator.

  20. Future directions in 980-nm pump lasers: submarine deployment to low-cost watt-class terrestrial pumps

    NASA Astrophysics Data System (ADS)

    Gulgazov, Vadim N.; Jackson, Gordon S.; Lascola, Kevin M.; Major, Jo S.; Parke, Ross; Richard, Tim; Rossin, Victor V.; Zhang, Kai

    1999-09-01

    . Since the failure rate allowable for an amplifier is not a function of the number of pumps employed in the amplifier, the allowable failure rate of an individual pump laser is decreasing for next-generation amplifiers. This will lead to specifications for terrestrial pumps well below 1000 FIT, and may lead to the case where high power amplifiers need laser pump reliability to approach 100 FIT. In addition, 980 nm laser diodes are now being deployed in submarine systems where failure rates lower than 100 FIT are commonly specified. It is obvious that both terrestrial and submarine markets are pushing allowable failure rates for pumps for optical amplifiers to continually decrease. A second push for improvement is in the output power of 980 nm pump modules. There exist a number of motivations for increasing the output power of pump lasers. First, each additional channel in a DWDM system requires additional power. To first order, a doubling in channel count implies a doubling in pump power. Second, larger amplifiers require multiple pumps. Higher output power from pump modules allows for fewer pumps, less complicated control systems and smaller size amplifiers. The discussion of this paper will focus on how current development progress of 980 nm laser diodes addresses these issues: better reliability and higher output powers.

  1. OSCILLATORY PUMP

    DOEpatents

    Underwood, N.

    1958-09-23

    This patent relates to a pump suitable fur pumping highly corrosive gases wherein no lubricant is needed in the pumping chamber thus eliminating possible contamination sources. The chamber contains a gas inlet and outlet in each side, with a paddle like piston suspended by a sylphon seal between these pcrts. An external arrangement causes the paddle to oscillate rapidly between the ports, alternately compressing and exhausting the gas trapped on each side of the paddle. Since the paddle does nnt touch the chamber sides at any point, no lubricant is required. This pump is useful for pumping large quantities of uranium hexafluorine.

  2. Vacuum pumps and systems: A review of current practice

    NASA Technical Reports Server (NTRS)

    Giles, Stuart

    1986-01-01

    A review of the fundamental characteristics of the many types of vacuum pumps and vacuum pumping systems is given. The optimum pumping range, relative cost, performance limitations, maintenance problems, system operating costs and similar subjects are discussed. Experiences from the thin film deposition, chemical processing, material handling, food processing and other industries, as well as space simulation are used to support conclusions and recommendations.

  3. Topological magnetoelectric pump in three dimensions

    NASA Astrophysics Data System (ADS)

    Fukui, Takahiro; Fujiwara, Takanori

    2017-11-01

    We study the topological pump for a lattice fermion model mainly in three spatial dimensions. We first calculate the U(1) current density for the Dirac model defined in continuous space-time to review the known results as well as to introduce some technical details convenient for the calculations of the lattice model. We next investigate the U(1) current density for a lattice fermion model, a variant of the Wilson-Dirac model. The model we introduce is defined on a lattice in space but in continuous time, which is suited for the study of the topological pump. For such a model, we derive the conserved U(1) current density and calculate it directly for the (1 +1 )-dimensional system as well as (3 +1 )-dimensional system in the limit of the small lattice constant. We find that the current includes a nontrivial lattice effect characterized by the Chern number, and therefore the pumped particle number is quantized by the topological reason. Finally, we study the topological temporal pump in 3 +1 dimensions by numerical calculations. We discuss the relationship between the second Chern number and the first Chern number, the bulk-edge correspondence, and the generalized Streda formula which enables us to compute the second Chern number using the spectral asymmetry.

  4. Robotic hand and fingers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salisbury, Curt Michael; Dullea, Kevin J.

    Technologies pertaining to a robotic hand are described herein. The robotic hand includes one or more fingers releasably attached to a robotic hand frame. The fingers can abduct and adduct as well as flex and tense. The fingers are releasably attached to the frame by magnets that allow for the fingers to detach from the frame when excess force is applied to the fingers.

  5. Rotating and positive-displacement pumps for low-thrust rocket engines. Volume 1: Pump Evaluation and design. [of centrifugal pumps

    NASA Technical Reports Server (NTRS)

    Macgregor, C.; Csomor, A.

    1974-01-01

    Rotating and positive displacement pumps of various types were studied for pumping liquid fluorine for low-thrust, high-performance rocket engines. Included in the analysis were: centrifugal, pitot, Barske, Tesla, drag, gear, vane, axial piston, radial piston, diaphragm, and helirotor pump concepts. The centrifugal pump and the gear pump were selected and these were carried through detailed design and fabrication. Mechanical difficulties were encountered with the gear pump during the preliminary tests in Freon-12. Further testing and development was therefore limited to the centrifugal pump. Tests on the centrifugal pump were conducted in Freon-12 to determine the hydrodynamic performance and in liquid fluorine to demonstrate chemical compatibility.

  6. 20. Station Unwatering Pumps and Sump Pump, view to the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Station Unwatering Pumps and Sump Pump, view to the north. The station unwatering pumps are the two large units in the center and right foreground of photograph and are marked with the numbers 1 and 2. The sump pump is the smaller unit in left foreground of photograph. These pumps are used for unwatering the draft chests for maintenance. Note the draft tube unwatering valve visible in background between the two unwatering pumps. - Washington Water Power Clark Fork River Noxon Rapids Hydroelectric Development, Powerhouse, South bank of Clark Fork River at Noxon Rapids, Noxon, Sanders County, MT

  7. Charge carrier dynamics of GaAs/AlGaAs asymmetric double quantum wells at room temperature studied by optical pump terahertz probe spectroscopy

    NASA Astrophysics Data System (ADS)

    Afalla, Jessica; Ohta, Kaoru; Tokonami, Shunrou; Prieto, Elizabeth Ann; Catindig, Gerald Angelo; Cedric Gonzales, Karl; Jaculbia, Rafael; Vasquez, John Daniel; Somintac, Armando; Salvador, Arnel; Estacio, Elmer; Tani, Masahiko; Tominaga, Keisuke

    2017-11-01

    Two asymmetric double quantum wells of different coupling strengths (barrier widths) were grown via molecular beam epitaxy, both samples allowing tunneling. Photoluminescence was measured at 10 and 300 K to provide evidence of tunneling, barrier dependence, and structural uniformity. Carrier dynamics at room temperature was investigated by optical pump terahertz probe (OPTP) spectroscopy. Carrier population decay rates were obtained and photoconductivity spectra were analyzed using the Drude model. This work demonstrates that carrier, and possibly tunneling dynamics in asymmetric double quantum well structures may be studied at room temperature through OPTP spectroscopy.

  8. ELECTROMAGNETIC PUMP

    DOEpatents

    Pulley, O.O.

    1954-08-17

    This patent reiates to electromagnetic pumps for electricity-conducting fluids and, in particular, describes several modifications for a linear conduction type electromagnetic interaction pump. The invention resides in passing the return conductor for the current traversing the fiuid in the duct back through the gap in the iron circuit of the pump. Both the maximum allowable pressure and the efficiency of a linear conduction electromagnetic pump are increased by incorporation of the present invention.

  9. A computerized system to evaluate volumetric infusion pumps.

    PubMed

    Kobayashi, S; Ogata, T

    1992-01-01

    A computerized system was developed to examine the performance characteristics of infusion pumps. This system collects solution delivered by an infusion pump through an intravenous needle into a collection vessel. Using an inductor-type weight sensor and a semiconductor type of strain-gauge pressure sensor, the weight of the collection vessel and the pressure at the needle were monitored over a specific period (the sampling time), and changes in pressure, flow rate, and volume of fluid were calculated. This system was applied to five volumetric infusion pumps with different pumping mechanisms. Test conditions involved two different solutions, two sizes of needle gauge, and seven flow rates, for a total of 28 measurements per pump. Results showed considerable variation in the infusion pumps' performances based on differences in these indices. Use of an inductance weight sensor as a means to evaluate gravimetric performance appears to be an improvement over conventional methods, which use analytical balances for data generation. The results indicate that this system will be useful in evaluating the performances of commercially available infusion pumps as well as those in development.

  10. Tank farms pump critical characteristic and specification guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Titzler, P.A.

    The Design Authority group for Tank Farms, in conjunction with the Construction Projects organization, have recognized that there is a need to provide consistency in the procurement and testing of pumps and to assure that known critical attributes and features are included with each pump order as well as to reduce potential confusion by pump suppliers. As a result, a panel of pump experts representing Lockheed Martin Hanford Company (LMHC), Fluor Daniel Northwest (FDNW), Numatec Hanford Corporation (NHC), SGN Eurisys Services Corporation (SESC), and ARES Corporation has been assembled to prepare a guide for pump specifications. This document contains themore » consensus listing of critical characteristics and procurement recommendations of the panel. It is intended to be used as a guide for future pump procurement activities. If followed, it will help reduce cleanup costs at the Hanford Site and promote prompt approval of pumping system designs and procurement specifications. Alternate criteria may be specified on a case by case basis if deviation from the requirements contained herein is merited due to special circumstances.« less

  11. Estimating Hyrdologic Properties of Groundwater Wells Using Tracer Pulse Dynamic Flow Profiling

    NASA Astrophysics Data System (ADS)

    Miles, K. A.; Heller, N.

    2016-12-01

    Traditional groundwater well design places the pump intake above the top of the well screen. It is common in this case to design the well screen for uniform entrance velocity along the profile of the well screen, even though non-uniform flow may occur. Particularly in the case where the pump is set near the very top or bottom of the well, there are instances where the zonal testing with a test pump indicates favorable water quality at one pump depth of the groundwater production well, and the water quality results yielded from the well at another depth are not compliant with federal and state regulatory limits for various naturally occurring and anthropogenic compounds. Well bore flow velocity and chemistry were determined using the USGS Tracer Pulse Dynamic Flow Profiling method along the length of well screens, while varying the pump depth. The information was then used to perform a flow and chemical mass balance to characterize the distribution of flow and chemical contribution, groundwater well screen entrance velocities, and hydrologic parameters. The presented results show pump placement affecting the average chemical discharge, and entrance velocities along the length of well screens.

  12. Microfluidic Pumps Containing Teflon [Trademark] AF Diaphragms

    NASA Technical Reports Server (NTRS)

    Willis, Peter; White, Victor; Grunthaner, Frank; Ikeda, Mike; Mathies, Richard A.

    2009-01-01

    Microfluidic pumps and valves based on pneumatically actuated diaphragms made of Teflon AF polymers are being developed for incorporation into laboratory-on-a-chip devices that must perform well over temperature ranges wider than those of prior diaphragm-based microfluidic pumps and valves. Other potential applications include implanted biomedical microfluidic devices, wherein the biocompatability of Teflon AF polymers would be highly advantageous. These pumps and valves have been demonstrated to function stably after cycling through temperatures from -125 to 120 C. These pumps and valves are intended to be successors to similar prior pumps and valves containing diaphragms made of polydimethylsiloxane (PDMS) [commonly known as silicone rubber]. The PDMS-containing valves ae designed to function stably only within the temperature range from 5 to 80 C. Undesirably, PDMS membranes are somwehat porous and retain water. PDMS is especially unsuitable for use at temperatures below 0 C because the formation of ice crystals increases porosity and introduces microshear.

  13. An Experimental Evaluation of Oil Pumping Rings

    NASA Technical Reports Server (NTRS)

    Eusepi, M. W.; Walowit, J.; Cohen, M.

    1981-01-01

    The design and construction of a reciprocating test vehicle to be used in evaluating hydrodynamic oil pumping rings are discussed. In addition, experimental test data are presented for three pumping ring designs that were constructed from Tin-Based Babbitt (SAE 11), Bearing Bronze (SAE 660), and Mechanical Carbon Graphite (Union Carbide Grade CNF-J). Data of pumped flow rate versus delivered pressure, as well as friction loss, are reported for the following conditions: frequencies of 10, 35 and 45 Hz; strokes of 25.4 mm (1.00 in.), 38.1 mm (1.50 in.) and 50.8 mm (2.00 in.) oil inlet temperature of 49 degrees (120 degrees); and pumping ring close-in pressures of 10.3 MPa (1500 lb/square inch. A 20W40 automotive oil was used for all tests. The maximum delivered pressure was 11 MPa (1600 lb/square inch. An analysis of hydrodynamic oil pumping rings was performed and the results of the analysis were compared to measured test data.

  14. Resonantly pumped high efficiency Ho:YAG laser.

    PubMed

    Shen, Ying-Jie; Yao, Bao-Quan; Duan, Xiao-Ming; Dai, Tong-Yu; Ju, You-Lun; Wang, Yue-Zhu

    2012-11-20

    High-efficient CW and Q-switched Ho:YAG lasers resonantly dual-end-pumped by two diode-pumped Tm:YLF lasers at 1908 nm were investigated. A maximum slope efficiency of 74.8% in CW operation as well as a maximum output power of 58.7 W at 83.2 W incident pump power was achieved, which corresponded to an optical-to-optical conversion efficiency of 70.6%. The maximum pulse energy of 2.94 mJ was achieved, with a 31 ns FWHM pulse width and a peak power of approximately 94.7 kW.

  15. Control of Brillouin short-pulse seed amplification by chirping the pump pulse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lehmann, G.; Spatschek, K. H.

    Seed amplification via Brillouin backscattering of a long pump pulse is considered. Similar to Raman amplification, several obstructive effects may occur during short-pulse Brillouin amplification. One is the spontaneous Raman backscattering of the pump before interacting with the seed. Preforming the plasma and/or chirping the pump will reduce unwanted pump backscattering. Optimized regions for low-loss pump propagation were proposed already in conjunction with Raman seed amplification. Hence, the influence of the chirp of the pump during Brillouin interaction with the seed becomes important and will be considered here. Both, the linear as well as the nonlinear evolution phases of themore » seed caused by Brillouin amplification under the action of a chirped pump are investigated. The amplification rate as well as the seed profiles are presented as function of the chirping rate. Also the dependence of superradiant scaling rates on the chirp parameter is discussed.« less

  16. Variable speed drives for pumps used in intensive pond culture systems

    USDA-ARS?s Scientific Manuscript database

    Prior to about 2010, the only large pumps on most catfish farms were those associated with the water supply. Water from wells is usually pumped to the surface using single-speed, vertical, lineshaft turbine pumps powered by three phase, electric motors. Since 2010, several catfish farmers have bui...

  17. Investigation of pump and pump switch failures in rainwater harvesting systems

    NASA Astrophysics Data System (ADS)

    Moglia, Magnus; Gan, Kein; Delbridge, Nathan; Sharma, Ashok K.; Tjandraatmadja, Grace

    2016-07-01

    Rainwater harvesting is an important technology in cities that can contribute to a number of functions, such as sustainable water management in the face of demand growth and drought as well as the detention of rainwater to increase flood protection and reduce damage to waterways. The objective of this article is to investigate the integrity of residential rainwater harvesting systems, drawing on the results of the field inspection of 417 rainwater systems across Melbourne that was combined with a survey of householders' situation, maintenance behaviour and attitudes. Specifically, the study moves beyond the assumption that rainwater systems are always operational and functional and draws on the collected data to explore the various reasons and rates of failure associated with pumps and pump switches, leaving for later further exploration of the failure in other components such as the collection area, gutters, tank, and overflows. To the best of the authors' knowledge, there is no data like this in academic literature or in the water sector. Straightforward Bayesian Network models were constructed in order to analyse the factors contributing to various types of failures, including system age, type of use, the reason for installation, installer, and maintenance behaviour. Results show that a number of issues commonly exist, such as failure of pumps (5% of systems), automatic pump switches that mediate between the tank and reticulated water (9% of systems), and systems with inadequate setups (i.e. no pump) limiting their use. In conclusion, there appears to be a lack of enforcement or quality controls in both installation practices by sometimes unskilled contractors and lack of ongoing maintenance checks. Mechanisms for quality control and asset management are required, but difficult to promote or enforce. Further work is needed into how privately owned assets that have public benefits could be better managed.

  18. Multistage quantum absorption heat pumps.

    PubMed

    Correa, Luis A

    2014-04-01

    It is well known that heat pumps, while being all limited by the same basic thermodynamic laws, may find realization on systems as "small" and "quantum" as a three-level maser. In order to quantitatively assess how the performance of these devices scales with their size, we design generalized N-dimensional ideal heat pumps by merging N-2 elementary three-level stages. We set them to operate in the absorption chiller mode between given hot and cold baths and study their maximum achievable cooling power and the corresponding efficiency as a function of N. While the efficiency at maximum power is roughly size-independent, the power itself slightly increases with the dimension, quickly saturating to a constant. Thus, interestingly, scaling up autonomous quantum heat pumps does not render a significant enhancement beyond the optimal double-stage configuration.

  19. Pumping tests in nonuniform aquifers - The radially symmetric case

    USGS Publications Warehouse

    Butler, J.J.

    1988-01-01

    Traditionally, pumping-test-analysis methodology has been limited to applications involving aquifers whose properties are assumed uniform in space. This work attempts to assess the applicability of analytical methodology to a broader class of units with spatially varying properties. An examination of flow behavior in a simple configuration consisting of pumping from the center of a circular disk embedded in a matrix of differing properties is the basis for this investigation. A solution describing flow in this configuration is obtained through Laplace-transform techniques using analytical and numerical inversion schemes. Approaches for the calculation of flow properties in conditions that can be roughly represented by this simple configuration are proposed. Possible applications include a wide variety of geologic structures, as well as the case of a well skin resulting from drilling or development. Of more importance than the specifics of these techniques for analysis of water-level responses is the insight into flow behavior during a pumping test that is provided by the large-time form of the derived solution. The solution reveals that drawdown during a pumping test can be considered to consist of two components that are dependent and independent of near-well properties, respectively. Such an interpretation of pumping-test drawdown allows some general conclusions to be drawn concerning the relationship between parameters calculated using analytical approaches based on curve-matching and those calculated using approaches based on the slope of a semilog straight line plot. The infinite-series truncation that underlies the semilog analytical approaches is shown to remove further contributions of near-well material to total drawdown. In addition, the semilog distance-drawdown approach is shown to yield an expression that is equivalent to the Thiem equation. These results allow some general recommendations to be made concerning observation-well placement for pumping

  20. 32 CFR Appendix A to Part 552 - DPCA Recreational Areas in Training Areas

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... guests. Boat launch adjacent to Officer's Club Beach on American Lake/Beachwood area Cat Lake Picnic and Fishing Area—Training Area 19 Chambers Lake Picnic and *Fishing Area—Training Area 12 (See para 2 below) Ecology Park Hiking Path—North Fort, CTA A West Fiander Lake Picnic and Fishing Area—Training Area 20...

  1. 32 CFR Appendix A to Part 552 - DPCA Recreational Areas in Training Areas

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... guests. Boat launch adjacent to Officer's Club Beach on American Lake/Beachwood area Cat Lake Picnic and Fishing Area—Training Area 19 Chambers Lake Picnic and *Fishing Area—Training Area 12 (See para 2 below) Ecology Park Hiking Path—North Fort, CTA A West Fiander Lake Picnic and Fishing Area—Training Area 20...

  2. 32 CFR Appendix A to Part 552 - DPCA Recreational Areas in Training Areas

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... guests. Boat launch adjacent to Officer's Club Beach on American Lake/Beachwood area Cat Lake Picnic and Fishing Area—Training Area 19 Chambers Lake Picnic and *Fishing Area—Training Area 12 (See para 2 below) Ecology Park Hiking Path—North Fort, CTA A West Fiander Lake Picnic and Fishing Area—Training Area 20...

  3. 32 CFR Appendix A to Part 552 - DPCA Recreational Areas in Training Areas

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... guests. Boat launch adjacent to Officer's Club Beach on American Lake/Beachwood area Cat Lake Picnic and Fishing Area—Training Area 19 Chambers Lake Picnic and *Fishing Area—Training Area 12 (See para 2 below) Ecology Park Hiking Path—North Fort, CTA A West Fiander Lake Picnic and Fishing Area—Training Area 20...

  4. 32 CFR Appendix A to Part 552 - DPCA Recreational Areas in Training Areas

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... guests. Boat launch adjacent to Officer's Club Beach on American Lake/Beachwood area Cat Lake Picnic and Fishing Area—Training Area 19 Chambers Lake Picnic and *Fishing Area—Training Area 12 (See para 2 below) Ecology Park Hiking Path—North Fort, CTA A West Fiander Lake Picnic and Fishing Area—Training Area 20...

  5. Multiple pump housing

    DOEpatents

    Donoho, II, Michael R.; Elliott; Christopher M.

    2010-03-23

    A fluid delivery system includes a first pump having a first drive assembly, a second pump having a second drive assembly, and a pump housing. At least a portion of each of the first and second pumps are located in the housing.

  6. Winding for linear pump

    DOEpatents

    Kliman, G.B.; Brynsvold, G.V.; Jahns, T.M.

    1989-08-22

    A winding and method of winding for a submersible linear pump for pumping liquid sodium are disclosed. The pump includes a stator having a central cylindrical duct preferably vertically aligned. The central vertical duct is surrounded by a system of coils in slots. These slots are interleaved with magnetic flux conducting elements, these magnetic flux conducting elements forming a continuous magnetic field conduction path along the stator. The central duct has placed therein a cylindrical magnetic conducting core, this core having a cylindrical diameter less than the diameter of the cylindrical duct. The core once placed to the duct defines a cylindrical interstitial pumping volume of the pump. This cylindrical interstitial pumping volume preferably defines an inlet at the bottom of the pump, and an outlet at the top of the pump. Pump operation occurs by static windings in the outer stator sequentially conveying toroidal fields from the pump inlet at the bottom of the pump to the pump outlet at the top of the pump. The winding apparatus and method of winding disclosed uses multiple slots per pole per phase with parallel winding legs on each phase equal to or less than the number of slots per pole per phase. The slot sequence per pole per phase is chosen to equalize the variations in flux density of the pump sodium as it passes into the pump at the pump inlet with little or no flux and acquires magnetic flux in passage through the pump to the pump outlet. 4 figs.

  7. Winding for linear pump

    DOEpatents

    Kliman, Gerald B.; Brynsvold, Glen V.; Jahns, Thomas M.

    1989-01-01

    A winding and method of winding for a submersible linear pump for pumping liquid sodium is disclosed. The pump includes a stator having a central cylindrical duct preferably vertically aligned. The central vertical duct is surrounded by a system of coils in slots. These slots are interleaved with magnetic flux conducting elements, these magnetic flux conducting elements forming a continuous magnetic field conduction path along the stator. The central duct has placed therein a cylindrical magnetic conducting core, this core having a cylindrical diameter less than the diameter of the cylindrical duct. The core once placed to the duct defines a cylindrical interstitial pumping volume of the pump. This cylindrical interstitial pumping volume preferably defines an inlet at the bottom of the pump, and an outlet at the top of the pump. Pump operation occurs by static windings in the outer stator sequentially conveying toroidal fields from the pump inlet at the bottom of the pump to the pump outlet at the top of the pump. The winding apparatus and method of winding disclosed uses multiple slots per pole per phase with parallel winding legs on each phase equal to or less than the number of slots per pole per phase. The slot sequence per pole per phase is chosen to equalize the variations in flux density of the pump sodium as it passes into the pump at the pump inlet with little or no flux and acquires magnetic flux in passage through the pump to the pump outlet.

  8. Analytical Solution for Flow to a Partially Penetrating Well with Storage in a Confined Aquifer

    NASA Astrophysics Data System (ADS)

    Vesselinov, V. V.; Mishra, P. K.; Neuman, S. P.

    2009-12-01

    Analytical solutions for radial flow toward a pumping well are commonly applied to analyze pumping tests conducted in confined aquifers. However, the existing analytical solutions are not capable to simultaneously take into account aquifer anisotropy, partial penetration, and wellbore storage capacity of pumping well. Ignoring these effects may have important impact on the estimated aquifer properties. We present a new analytical solution for three-dimensional, axially symmetric flow to a pumping well in confined aquifer that accouts for aquifer anisotropy, partial penetration and wellbore storage capacity of pumping well. Our analytical reduces to that of Papadopulos et.al. [1967] when the pumping well is fully penetrating, Hantush [1964] when the pumping well has no wellbore storage, and Theis [1935] when both conditions are fulfilled. The solution is evaluated through numerical inversion of its Laplace transform. We use our new solution to analyze data from synthetic and real pumping tests.

  9. Thermodynamic performance of multi-stage gradational lead screw vacuum pump

    NASA Astrophysics Data System (ADS)

    Zhao, Fan; Zhang, Shiwei; Sun, Kun; Zhang, Zhijun

    2018-02-01

    As a kind of dry mechanical vacuum pump, the twin-screw vacuum pump has an outstanding pumping performance during operation, widely used in the semiconductor industry. Compared with the constant lead screw (CLS) vacuum pump, the gradational lead screw (GLS) vacuum pump is more popularly applied in recent years. Nevertheless, not many comparative studies on the thermodynamic performance of GLS vacuum pump can be found in the literature. Our study focuses on one type of GLS vacuum pump, the multi-stage gradational lead screw (MGLS) vacuum pump, gives a detailed description of its construction and illustrates it with the drawing. Based on the structural analysis, the thermodynamic procedure is divided into four distinctive processes, including sucking process, transferring (compressing) process, backlashing process and exhausting process. The internal mechanism of each process is qualitatively illustrated and the mathematical expressions of seven thermodynamic parameters are given under the ideal situation. The performance curves of MGLS vacuum pump are plotted by MATLAB software and compared with those of the CLS vacuum pump in the same case. The results can well explain why the MGLS vacuum pump has more favorable pumping performance than the CLS vacuum pump in saving energy, reducing noise and heat dissipation.

  10. 5. Station Unwatering Pumps and Sump Pump for Units 1 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Station Unwatering Pumps and Sump Pump for Units 1 and 2, view to the west. The unwatering pumps are the two larger items toward the right side of the photograph (one in foreground and one in background. The smaller item toward the left of the photograph is the sump pump. These pumps are used for draining water from the draft chest for maintenance. - Washington Water Power Clark Fork River Cabinet Gorge Hydroelectric Development, Powerhouse, North Bank of Clark Fork River at Cabinet Gorge, Cabinet, Bonner County, ID

  11. A new blood pump for cardiopulmonary bypass: the HiFlow centrifugal pump.

    PubMed

    Göbel, C; Eilers, R; Reul, H; Schwindke, P; Jörger, M; Rau, G

    1997-07-01

    Centrifugal blood pumps are considered to be generally superior to the traditionally used roller pumps in cardiopulmonary bypass. In our institute a new lightweight centrifugal sealless blood pump with a unique spherical thrust bearing and with a magnetic coupling was developed, the HiFlow. The small design makes the pump suitable for applications in complex devices or close to a patient. Hemolysis tests were carried out in which the BioMedicus pump BP-80 and a roller pump were used as reference. The centrifugal pump HiFlow showed the least blood trauma within the group of investigated pumps. In summary, the HiFlow pump concept with its low priming volume and limited contact surfaces shows great potential for clinical applications in cardiopulmonary bypass. Also, the possibility of using the pump as a short-term assist device with an option of a pulsatile driving mode was demonstrated.

  12. Hydraulic refinement of an intraarterial microaxial blood pump.

    PubMed

    Siess, T; Reul, H; Rau, G

    1995-05-01

    Intravascularly operating microaxial pumps have been introduced clinically proving to be useful tools for cardiac assist. However, a number of complications have been reported in literature associated with the extra-corporeal motor and the flexible drive shaft cable. In this paper, a new pump concept is presented which has been mechanically and hydraulically refined during the developing process. The drive shaft cable has been replaced by a proximally integrated micro electric motor and an extra-corporeal power supply. The conduit between pump and power supply consists of only an electrical power cable within the catheter resulting in a device which is indifferent to kinking and small curvature radii. Anticipated insertion difficulties, as a result of a large outer pump diameter, led to a two-step approach with an initial 6,4mm pump version and a secondary 5,4mm version. Both pumps meet the hydraulic requirement of at least 2.5l/min at a differential pressure of 80-100 mmHg. The hydraulic refinements necessary to achieve the anticipated goal are based on ongoing hydrodynamic studies of the flow inside the pumps. Flow visualization on a 10:1 scale model as well as on 1:1 scale pumps have yielded significant improvements in the overall hydraulic performance of the pumps. One example of this iterative developing process by means of geometrical changes on the basis of flow visualization is illustrated for the 6.4mm pump.

  13. Evaluation of the Coreless Linear Conduction Pump for Thermoelectromagnetic Pumps,

    DTIC Science & Technology

    1991-08-01

    Accession Number: 4466 Publication Date: Aug 01, 1991 Title: Evaluation of the Coreless Linear Conduction Pump for Thermoelectromagnetic Pumps ...083191 Report Prepared for: SDIO/T/SL, Washington, DC 20301-7100 Descriptors, Keywords: Coreless Linear Conduction Pump Thermoelectromagnetic...000001 Record ID: 26727 SUMMARY The purpose of the Coreless Linear Conduction Pump (CLCP) was to evaluate the feasibility of the CLCP as a means of

  14. Study on the Pumped Materials along Rail Bed in Taiwan

    NASA Astrophysics Data System (ADS)

    Kuo, Chihping; Hsu, Chihhao; Wu, Chinwei; Wang, Hongyi

    2016-04-01

    The Neiwan Line is a railway branch line in Taiwan operated by the Taiwan Railways Administration. It is located in Hsinchu County. This line was completed on 11 September 1951. Although this line is a branch line, its standards are comparable to those of a main line except that it is not electrified. The materials for constructing railway subgrade were general in-situ topsoil which deposited in Pliocene. This line suffers the subgrade mud pumping frequently. Railway subgrade mud pumping is one of the most common defects on railway constructions. Most cases of the pumping phenomenon are caused in mud, say silt or ML in USCS. However, field observation and loggings show that not only silt but also other kinds of soil, such as sand or clay, pump as well in this study. Thirty pumping samples were collected in a sectional zone which length is about 12kM. In the 30 samples, 12 ones are Sand, 10 ones are Silt, 6 ones are Clay, and 2 ones are Gravel. Under very similar conditions, such as natural geological material, train operations, the reasons why different soil caused pumping is well discussed in this paper.

  15. Synchronization modulation of Na/K pumps on Xenopus oocytes

    NASA Astrophysics Data System (ADS)

    Liang, Pengfei; Mast, Jason; Chen, Wei

    We developed a new technique named synchronization modulation to electrically synchronize and modulate the Na/K pump molecules by a specially designed oscillating electric field. This technique is based on the theory of energy-trap in quantum physics as well as the concept of electronic synchrotron accelerator. As a result, the Na-transports are all entrapped into the positive half-cycle of the applied electric field and consequently, all of the K-transports are entrapped into the negative half cycle of the field. To demonstrate the process of the pump synchronization and modulation, we use Xenopus oocytes as a platform and introduce two-electrode whole-cell voltage clamp in measurement of pump current. Practically, we first synchronize the pump molecules running at the same pace (rate and phase) by a specially designed oscillation electric field. Then, we carefully maintain the pump synchronization status and gradually change the field frequency (decrease and increase) to modulate the pump molecules to newer pumping rate. The result shows a separation of the inward K current from the outward Na current, and about 10 time increase of the total (inward plus outward) pump current from the net outward current from the random paced pump molecules. Also, the ratio of the modulated total pump current with synchronized total pump current is consistent with the ratio of their field frequencies.

  16. Hydraulic pump with in-ground filtration and monitoring capability

    DOEpatents

    Hopkins, C.D.; Livingston, R.R.; Toole, W.R. Jr.

    1995-01-01

    A hydraulically operated pump is described for in-ground filtering and monitoring of wells or other fluid sources, including a hollow cylindrical pump housing with an inlet and an outlet, filtering devices positioned in the inlet and the outlet, a piston that fits slidably within the pump housing, and an optical cell in fluid communication with the pump housing. A conduit within the piston allows fluid communication between the exterior and one end of the piston. A pair of O-rings form a seal between the inside of the pump housing and the exterior of the piston. A flow valve positioned within the piston inside the conduit allows fluid to flow in a single direction. In operation, fluid enters the pump housing through the inlet, flows through the conduit and towards an end of the pump housing. The piston then makes a downward stroke closing the valve, thus forcing the fluid out from the pump housing into the optical cell, which then takes spectrophotometric measurements of the fluid. A spring helps return the piston back to its starting position, so that a new supply of fluid may enter the pump housing and the downward stroke can begin again. The pump may be used independently of the optical cell, as a sample pump to transport a sample fluid from a source to a container for later analysis.

  17. Evolution of high-temperature geothermal brine production pumps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ellis, P.F. II

    1989-01-01

    Geothermal resources with temperatures between 250{degrees} and 360{degrees}F (121{degrees} and 182{degrees}C) are prime candidates for binary-cycle power generation in the United States and abroad, and constitute about 80% of the known power-capable resources in the United States. Initially there were many technological obstacles to exploitation of these resources, with one of the greatest being the absence of reliable high-capacity downwell brine production pumps to supply the required amounts of brine from an economically small group of wells. Early experience revealed many problems with downwell pumps, resulting in a mean-time-to-failure (MTTF) in 1981 of less than 1000 hours for the bestmore » available technology. This paper reports how evolutionary advances in pump design and materials selection have resolved most of the early problems, producing third- generation pumps which have run as long as 20,000 hours. Pump life extension practices - greatly enhanced component and assembly quality control, increased care in pump installation, and continuous monitoring of pump performance with swift intervention at the first signs of distress - have essentially eliminated premature failure where implemented, leading to estimated near-term MTTFs of 8000 hours.« less

  18. 32. PLAN OF DEER ISLAND PUMPING STATION SHOWING EXISTING PUMPING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    32. PLAN OF DEER ISLAND PUMPING STATION SHOWING EXISTING PUMPING PLANT AND LOCATION OF PROPOSED ADDITIONS, JULY 1898 SHEET NO. 1. Aperture card 4966-1 - Deer Island Pumping Station, Boston, Suffolk County, MA

  19. Solid-state laser pumping with a planar compound parabolic concentrator.

    PubMed

    Panteli, D V; Pani, B M; Beli, L Z

    1997-10-20

    A novel solid-state laser-pumping scheme is proposed that combines a reflective lamp chamber and a compound parabolic concentrator (CPC) as a light guide. The CPC is made of a transparent material of high refractive index, and light is guided by the total internal reflection, with drastically reduced reflection losses. Material is chosen so that the absorption losses are minimized in the pumping wavelength range. The lamp chamber is designed with the principles of nonimaging optics, which ensures that the radiation is efficiently transferred from the lamp to the input aperture of the CPC. The pumping efficiency was first estimated theoretically, which gave us enough justification for the more accurate calculations with ray tracing. Single as well as multiple pumping cavities are discussed. New pumping geometry results in significantly increased pumping efficiency compared with conventional geometries. Also the lamp and the laser rod are separated, leading to reduced thermal load. We found that the proposed pumping method is also applicable to diode-pumped lasers.

  20. Chemical pump study

    NASA Technical Reports Server (NTRS)

    Bergquist, L. E.

    1973-01-01

    Sorption pumps applicable to the Pioneer Venus Mass Spectrometer Experiment were investigated. The pump requirements are discussed, and a survey of the existing pumps presented. Zirconium and zirconium graphite products were found to be the most promising among the getter materials surveyed. A preliminary pump design for the noble gas experiment is discussed.

  1. Natural and Synthetic Polymers as Inhibitors of Drug Efflux Pumps

    PubMed Central

    2007-01-01

    Inhibition of efflux pumps is an emerging approach in cancer therapy and drug delivery. Since it has been discovered that polymeric pharmaceutical excipients such as Tweens® or Pluronics® can inhibit efflux pumps, various other polymers have been investigated regarding their potential efflux pump inhibitory activity. Among them are polysaccharides, polyethylene glycols and derivatives, amphiphilic block copolymers, dendrimers and thiolated polymers. In the current review article, natural and synthetic polymers that are capable of inhibiting efflux pumps as well as their application in cancer therapy and drug delivery are discussed. PMID:17896100

  2. TANK 26 EVAPORATOR FEED PUMP TRANSFER ANALYSIS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tamburello, D; Si Lee, S; Richard Dimenna, R

    2008-09-30

    The transfer of liquid salt solution from Tank 26 to an evaporator is to be accomplished by activating the evaporator feed pump, located approximately 72 inches above the sludge layer, while simultaneously turning on the downcomer. Previously, activation of the evaporator feed pump was an isolated event without any other components running at the same time. An analysis of the dissolved solution transfer has been performed using computational fluid dynamics methods to determine the amount of entrained sludge solids pumped out of the tank to the evaporator with the downcomer turned on. The analysis results showed that, for the maximummore » and minimum supernate levels in Tank 26 (252.5 and 72 inches above the sludge layer, respectively), the evaporator feed pump will entrain between 0.05 and 0.1 wt% sludge solids weight fraction into the eductor, respectively. Lower tank liquid levels, with respect to the sludge layer, result in higher amounts of sludge entrainment due to the increased velocity of the plunging jets from the downcomer and evaporator feed pump bypass as well as decreased dissipation depth.« less

  3. 33. PLAN OF DEER ISLAND PUMPING STATION SHOWING EXISTING PUMPING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. PLAN OF DEER ISLAND PUMPING STATION SHOWING EXISTING PUMPING PLAN AND LOCATION OF PROPOSED ADDITIONS, METROPOLITAN WATER AND SEWERAGE BOARD, METROPOLITAN SEWERAGE WORKS, JULY 1908. Aperture card 6417. - Deer Island Pumping Station, Boston, Suffolk County, MA

  4. Axial Pump

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor); Akkerman, James W. (Inventor); Aber, Gregory S. (Inventor); VanDamm, George Arthur (Inventor); Bacak, James W. (Inventor); Svejkovsky, Paul A. (Inventor); Benkowski, Robert J. (Inventor)

    1997-01-01

    A rotary blood pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial and radial clearances of blades associated with the flow straightener, inducer portion, impeller portion and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with cross-linked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

  5. Efficacy of alcohol-based hand sanitizer on hands soiled with dirt and cooking oil.

    PubMed

    Pickering, Amy J; Davis, Jennifer; Boehm, Alexandria B

    2011-09-01

    Handwashing education and promotion are well established as effective strategies to reduce diarrhea and respiratory illness in countries around the world. However, access to reliable water supplies has been identified as an important barrier to regular handwashing in low-income countries. Alcohol-based hand sanitizer (ABHS) is an effective hand hygiene method that does not require water, but its use is not currently recommended when hands are visibly soiled. This study evaluated the efficacy of ABHS on volunteers' hands artificially contaminated with Escherichia coli in the presence of dirt (soil from Tanzania) and cooking oil. ABHS reduced levels of E. coli by a mean of 2.33 log colony forming units (CFU) per clean hand, 2.32 log CFU per dirt-covered hand, and 2.13 log CFU per oil-coated hand. No significant difference in efficacy was detected between hands that were clean versus dirty or oily. ABHS may be an appropriate hand hygiene method for hands that are moderately soiled, and an attractive option for field settings in which access to water and soap is limited.

  6. Human lymphatic pumping measured in healthy and lymphoedematous arms by lymphatic congestion lymphoscintigraphy

    PubMed Central

    Modi, S; Stanton, A W B; Svensson, W E; Peters, A M; Mortimer, P S; Levick, J R

    2007-01-01

    Axillary surgery for breast cancer partially obstructs lymph outflow from the arm, chronically raising the lymphatic smooth muscle afterload. This may lead to pump failure, as in hypertensive cardiac failure, and could explain features of breast cancer treatment-related lymphoedema (BCRL) such as its delayed onset. A new method was developed to measure human lymphatic contractility non-invasively and test the hypothesis of contractile impairment. 99mTc-human IgG (Tc-HIG), injected into the hand dermis, drained into the arm lymphatic system which was imaged using a gamma-camera. Lymph transit time from hand to axilla, ttransit, was 9.6 ± 7.2 min (mean ±s.d.) (velocity 8.9 cm min−1) in seven normal subjects. To assess lymphatic contractility, a sphygmomanometer cuff around the upper arm was inflated to 60 mmHg (Pcuff) before 99mTc-HIG injection and maintained for >> ttransit. When Pcuff exceeded the maximum pressure generated by the lymphatic pump (Ppump), radiolabelled lymph was held up at the distal cuff border. Pcuff was then lowered in 10 mmHg steps until 99mTc-HIG began to flow under the cuff to the axilla, indicating Ppump≥Pcuff. In 16 normal subjects Ppump was 39 ± 14 mmHg. Ppump was 38% lower in 16 women with BCRL, namely 24 ± 19 mmHg (P = 0.014, Student's unpaired t test), and correlated negatively with the degree of swelling (12–56%). Blood radiolabel accumulation proved an unreliable measure of lymphatic pump function. Lymphatic congestion lymphoscintigraphy thus provided a quantitative measure of human lymphatic contractility without surgical cut-down, and the results supported the hypothesis of lymphatic pump failure in BCRL. PMID:17569739

  7. Diode pumped solid-state laser oscillators for spectroscopic applications

    NASA Technical Reports Server (NTRS)

    Byer, R. L.; Basu, S.; Fan, T. Y.; Kozlovsky, W. J.; Nabors, C. D.; Nilsson, A.; Huber, G.

    1987-01-01

    The rapid improvement in diode laser pump sources has led to the recent progress in diode laser pumped solid state lasers. To date, electrical efficiencies of greater than 10 percent were demonstrated. As diode laser costs decrease with increased production volume, diode laser and diode laser array pumped solid state lasers will replace the traditional flashlamp pumped Nd:YAG laser sources. The use of laser diode array pumping of slab geometry lasers will allow efficient, high peak and average power solid state laser sources to be developed. Perhaps the greatest impact of diode laser pumped solid state lasers will be in spectroscopic applications of miniature, monolithic devices. Single-stripe diode-pumped operation of a continuous-wave 946 nm Nd:YAG laser with less than 10 m/w threshold was demonstrated. A slope efficiency of 16 percent near threshold was shown with a projected slope efficiency well above a threshold of 34 percent based on results under Rhodamine 6G dye-laser pumping. Nonlinear crystals for second-harmonic generation of this source were evaluated. The KNbO3 and periodically poled LiNbO3 appear to be the most promising.

  8. Heat Radiators for Electromagnetic Pumps

    NASA Technical Reports Server (NTRS)

    Campana, R. J.

    1986-01-01

    Report proposes use of carbon/carbon composite radiators in electromagnetic coolant pumps of nuclear reactors on spacecraft. Carbon/carbon composite materials function well at temperatures in excess of 2,200 K. Aluminum has melting temperature of only 880 K.

  9. Gas pump with movable gas pumping panels

    DOEpatents

    Osher, John E.

    1984-01-01

    Apparatus for pumping gas continuously a plurality of articulated panels of getter material, each of which absorbs gases on one side while another of its sides is simultaneously reactivated in a zone isolated by the panels themselves from a working space being pumped.

  10. Gas pump with movable gas pumping panels

    DOEpatents

    Osher, J.L.

    Apparatus for pumping gas continuously a plurality of articulated panels of getter material, each of which absorbs gases on one side while another of its sides is simultaneously reactivated in a zone isolated by the panels themselves from a working space being pumped.

  11. Evidence for right-hand feeding biases in a left-handed population.

    PubMed

    Flindall, Jason W; Stone, Kayla D; Gonzalez, Claudia L R

    2015-05-01

    We have recently shown that actions with similar kinematic requirements, but different end-state goals may be supported by distinct neural networks. Specifically, we demonstrated that when right-handed individuals reach-to-grasp food items with intent to eat, they produce smaller maximum grip apertures (MGAs) than when they grasp the same item with intent to place it in a location near the mouth. This effect was restricted to right-handed movements; left-handed movements showed no difference between tasks. The current study investigates whether (and to which side) the effect may be lateralized in left-handed individuals. Twenty-one self-identified left-handed participants grasped food items of three different sizes while grasp kinematics were captured via an Optotrak Certus motion capture array. A main effect of task was identified wherein the grasp-to-eat action generated significantly smaller MGAs than did the grasp-to-place action. Further analysis revealed that similar to the findings in right-handed individuals, this effect was significant only during right-handed movements. Upon further inspection however, we found individual differences in the magnitude and direction of the observed lateralization. These results underscore the evolutionary significance of the grasp-to-eat movement in producing population-level right-handedness in humans as well as highlighting the heterogeneity of the left-handed population.

  12. Optical pumping and negative luminescence polarization in charged GaAs quantum dots

    NASA Astrophysics Data System (ADS)

    Shabaev, Andrew; Stinaff, Eric A.; Bracker, Allan S.; Gammon, Daniel; Efros, Alexander L.; Korenev, Vladimir L.; Merkulov, Igor

    2009-01-01

    Optical pumping of electron spins and negative photoluminescence polarization are observed when interface quantum dots in a GaAs quantum well are excited nonresonantly by circularly polarized light. Both observations can be explained by the formation of long-lived dark excitons through hole spin relaxation in the GaAs quantum well prior to exciton capture. In this model, optical pumping of resident electron spins is caused by capture of dark excitons and recombination in charged quantum dots. Negative polarization results from accumulation of dark excitons in the quantum well and is enhanced by optical pumping. The dark exciton model describes the experimental results very well, including intensity and bias dependence of the photoluminescence polarization and the Hanle effect.

  13. What Can We Learn About Karst Aquifer Heterogeneity From Pumping Tests

    NASA Astrophysics Data System (ADS)

    Marechal, J. C.; Dewandel, B.; Ladouche, B.; Fleury, P.

    2016-12-01

    Due to the complexity and duality of flows, well-test interpretation into karst systems constitutes a challenging task for hydrogeologists. This is especially true when the pumping well intersects karst heterogeneities such as the conduit network. The method of diagnostic plots, widely used in oil industry, can be applied to karst hydrogeology. In this paper, the classical response of a well-test into a karst conduit is described on a log-log drawdown derivative curve. It allows identifying successive flow regimes corresponding to the contribution of various karst aquifer subsystems (fractured matrix, karst conduit, main karst drainage network) to the pumped well. In heterogeneous karst systems, the log-log diagnostic plot of drawdown and its derivative in the pumping well can help identifying departures in flow-geometry from the classical homogeneous radial case. Classically, the diagnostic plot can be divided into several portions with: (a) early data used for identifying the karst conduit storage; (b) intermediate data for identifying the type of aquifer model that should be used (e.g. double porosity, anisotropy...); and (c) late data for identifying the possible boundaries. This is illustrated on three examples from Mediterranean karsts in southern France. A one-month duratio pumping test on a well intersecting the main karst drainage network of the Cent-Fonts karst system shows (i) a preliminary contribution of the karst conduit storage capacity followed by (ii) linear flows into the fractured matrix. A pumping test on a well intersecting a small karst conduit of the Corbières karst system shows the existence of (i) bi-linear flow within both the karst conduit and the fractured matrix at early times, followed by (ii) radial flows within the fractured matrix and (iii) finally the contribution of a major karst cavity. A two-months duration pumping test on a deep confined karst aquifer under low permeability rocks into the Gardanne basin shows the existence of

  14. Inward H+ pump xenorhodopsin: Mechanism and alternative optogenetic approach.

    PubMed

    Shevchenko, Vitaly; Mager, Thomas; Kovalev, Kirill; Polovinkin, Vitaly; Alekseev, Alexey; Juettner, Josephine; Chizhov, Igor; Bamann, Christian; Vavourakis, Charlotte; Ghai, Rohit; Gushchin, Ivan; Borshchevskiy, Valentin; Rogachev, Andrey; Melnikov, Igor; Popov, Alexander; Balandin, Taras; Rodriguez-Valera, Francisco; Manstein, Dietmar J; Bueldt, Georg; Bamberg, Ernst; Gordeliy, Valentin

    2017-09-01

    Generation of an electrochemical proton gradient is the first step of cell bioenergetics. In prokaryotes, the gradient is created by outward membrane protein proton pumps. Inward plasma membrane native proton pumps are yet unknown. We describe comprehensive functional studies of the representatives of the yet noncharacterized xenorhodopsins from Nanohaloarchaea family of microbial rhodopsins. They are inward proton pumps as we demonstrate in model membrane systems, Escherichia coli cells, human embryonic kidney cells, neuroblastoma cells, and rat hippocampal neuronal cells. We also solved the structure of a xenorhodopsin from the nanohalosarchaeon Nanosalina ( Ns XeR) and suggest a mechanism of inward proton pumping. We demonstrate that the Ns XeR is a powerful pump, which is able to elicit action potentials in rat hippocampal neuronal cells up to their maximal intrinsic firing frequency. Hence, inwardly directed proton pumps are suitable for light-induced remote control of neurons, and they are an alternative to the well-known cation-selective channelrhodopsins.

  15. 39. THREECYLINDER HYDRAULIC OIL PUMP (MANUFACTURED BY WORTHINGTON: PUMP AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    39. THREE-CYLINDER HYDRAULIC OIL PUMP (MANUFACTURED BY WORTHINGTON: PUMP AND MACHINERY COMPANY, HOLYOKE MASSACHUSETTS) IN MACHINERY CHAMBER FOR SLUICE GATE WORKS ON GALLERY 1. NOTE OIL TANK ABOVE PUMP MOTOR. VIEW TO NORTHWEST. - Owyhee Dam, Across Owyhee River, Nyssa, Malheur County, OR

  16. Overview of Pump Room, showing pumps at right and power ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Overview of Pump Room, showing pumps at right and power distribution cabinets for valve motors along north wall at left. View to east - Wellton-Mohawk Irrigation System, Pumping Plant No. 1, Bounded by Gila River & Union Pacific Railroad, Wellton, Yuma County, AZ

  17. DISK PUMP FEASIBILITY INVESTIGATION,

    DTIC Science & Technology

    system as an inducer and/or mainstage pump for liquid rocket applications. This investigation consisted of the analysis, design, and test of a disk...pumping action is a function of the viscous properties of the pumped fluid. (2) The pump does not require the conventional pump lifting forces. ( 3 ...with no apparent head deterioration. The representative maximum suction specific speed at a 3 % head drop was never reached. The pump demonstrated

  18. Interaction of Aquifer and River-Canal Network near Well Field.

    PubMed

    Ghosh, Narayan C; Mishra, Govinda C; Sandhu, Cornelius S S; Grischek, Thomas; Singh, Vikrant V

    2015-01-01

    The article presents semi-analytical mathematical models to asses (1) enhancements of seepage from a canal and (2) induced flow from a partially penetrating river in an unconfined aquifer consequent to groundwater withdrawal in a well field in the vicinity of the river and canal. The nonlinear exponential relation between seepage from a canal reach and hydraulic head in the aquifer beneath the canal reach is used for quantifying seepage from the canal reach. Hantush's (1967) basic solution for water table rise due to recharge from a rectangular spreading basin in absence of pumping well is used for generating unit pulse response function coefficients for water table rise in the aquifer. Duhamel's convolution theory and method of superposition are applied to obtain water table position due to pumping and recharge from different canal reaches. Hunt's (1999) basic solution for river depletion due to constant pumping from a well in the vicinity of a partially penetrating river is used to generate unit pulse response function coefficients. Applying convolution technique and superposition, treating the recharge from canal reaches as recharge through conceptual injection wells, river depletion consequent to variable pumping and recharge is quantified. The integrated model is applied to a case study in Haridwar (India). The well field consists of 22 pumping wells located in the vicinity of a perennial river and a canal network. The river bank filtrate portion consequent to pumping is quantified. © 2014, National GroundWater Association.

  19. Champagne Heat Pump

    NASA Technical Reports Server (NTRS)

    Jones, Jack A.

    2004-01-01

    The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

  20. 24. Pump Room interiordewatering pump motor on upper level. Note ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. Pump Room interior-dewatering pump motor on upper level. Note the removable roof hatch (steel frame) directly above motor. Dewatering pumps motor control center at left - Hunters Point Naval Shipyard, Drydock No. 4, East terminus of Palou Avenue, San Francisco, San Francisco County, CA

  1. Effects of changes in pumping on regional groundwater-flow paths, 2005 and 2010, and areas contributing recharge to discharging wells, 1990–2010, in the vicinity of North Penn Area 7 Superfund site, Montgomery County, Pennsylvania

    USGS Publications Warehouse

    Senior, Lisa A.; Goode, Daniel J.

    2017-06-06

    A previously developed regional groundwater flow model was used to simulate the effects of changes in pumping rates on groundwater-flow paths and extent of recharge discharging to wells for a contaminated fractured bedrock aquifer in southeastern Pennsylvania. Groundwater in the vicinity of the North Penn Area 7 Superfund site, Montgomery County, Pennsylvania, was found to be contaminated with organic compounds, such as trichloroethylene (TCE), in 1979. At the time contamination was discovered, groundwater from the underlying fractured bedrock (shale) aquifer was the main source of supply for public drinking water and industrial use. As part of technical support to the U.S. Environmental Protection Agency (EPA) during the Remedial Investigation of the North Penn Area 7 Superfund site from 2000 to 2005, the U.S. Geological Survey (USGS) developed a model of regional groundwater flow to describe changes in groundwater flow and contaminant directions as a result of changes in pumping. Subsequently, large decreases in TCE concentrations (as much as 400 micrograms per liter) were measured in groundwater samples collected by the EPA from selected wells in 2010 compared to 2005‒06 concentrations.To provide insight on the fate of potentially contaminated groundwater during the period of generally decreasing pumping rates from 1990 to 2010, steady-state simulations were run using the previously developed groundwater-flow model for two conditions prior to extensive remediation, 1990 and 2000, two conditions subsequent to some remediation 2005 and 2010, and a No Pumping case, representing pre-development or cessation of pumping conditions. The model was used to (1) quantify the amount of recharge, including potentially contaminated recharge from sources near the land surface, that discharged to wells or streams and (2) delineate the areas contributing recharge that discharged to wells or streams for the five conditions.In all simulations, groundwater divides differed from

  2. Magnetic pumping as a source of particle heating

    NASA Astrophysics Data System (ADS)

    Lichko, Emily; Egedal, Jan; Daughton, William; Kasper, Justin

    2017-10-01

    Magnetic pumping is a means of heating plasmas for both fusion and astrophysical applications. In this study a magnetic pumping model is developed as a possible explanation for the heating and the generation of power-law distribution functions observed in the solar wind plasma. In most previous studies turbulent energy is only dissipated at microscopic kinetic scales. In contrast, magnetic pumping energizes the particles through the largest scale turbulent fluctuations, thus bypassing the energy cascade. Kinetic simulations are applied to verify these analytic predictions. Previous results for the one-dimensional model, as well as initial results for a two-dimensional model which includes the effects of trapped and passing particles are presented. Preliminary results of the presence of this mechanism in the bow shock region, using spacecraft data from the Magnetospheric Multiscale mission, are presented as well. This research was conducted with support from National Defense Science and Engineering Graduate (NDSEG) Fellowship, 32 CFR 168, as well as from NSF Award 1404166 and NASA award NNX15AJ73G.

  3. Three-dimensional geostatistical inversion of flowmeter and pumping test data.

    PubMed

    Li, Wei; Englert, Andreas; Cirpka, Olaf A; Vereecken, Harry

    2008-01-01

    We jointly invert field data of flowmeter and multiple pumping tests in fully screened wells to estimate hydraulic conductivity using a geostatistical method. We use the steady-state drawdowns of pumping tests and the discharge profiles of flowmeter tests as our data in the inference. The discharge profiles need not be converted to absolute hydraulic conductivities. Consequently, we do not need measurements of depth-averaged hydraulic conductivity at well locations. The flowmeter profiles contain information about relative vertical distributions of hydraulic conductivity, while drawdown measurements of pumping tests provide information about horizontal fluctuation of the depth-averaged hydraulic conductivity. We apply the method to data obtained at the Krauthausen test site of the Forschungszentrum Jülich, Germany. The resulting estimate of our joint three-dimensional (3D) geostatistical inversion shows an improved 3D structure in comparison to the inversion of pumping test data only.

  4. Radio Pumping of Ionospheric Plasma with Orbital Angular Momentum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leyser, T. B.; Norin, L.; McCarrick, M.

    2009-02-13

    Experimental results are presented of pumping ionospheric plasma with a radio wave carrying orbital angular momentum (OAM), using the High Frequency Active Auroral Research Program (HAARP) facility in Alaska. Optical emissions from the pumped plasma turbulence exhibit the characteristic ring-shaped morphology when the pump beam carries OAM. Features of stimulated electromagnetic emissions (SEE) that are attributed to cascading Langmuir turbulence are well developed for a regular beam but are significantly weaker for a ring-shaped OAM beam in which case upper hybrid turbulence dominates the SEE.

  5. Radio pumping of ionospheric plasma with orbital angular momentum.

    PubMed

    Leyser, T B; Norin, L; McCarrick, M; Pedersen, T R; Gustavsson, B

    2009-02-13

    Experimental results are presented of pumping ionospheric plasma with a radio wave carrying orbital angular momentum (OAM), using the High Frequency Active Auroral Research Program (HAARP) facility in Alaska. Optical emissions from the pumped plasma turbulence exhibit the characteristic ring-shaped morphology when the pump beam carries OAM. Features of stimulated electromagnetic emissions (SEE) that are attributed to cascading Langmuir turbulence are well developed for a regular beam but are significantly weaker for a ring-shaped OAM beam in which case upper hybrid turbulence dominates the SEE.

  6. DEVELOPMENT OF COLD CLIMATE HEAT PUMP USING TWO-STAGE COMPRESSION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Bo; Rice, C Keith; Abdelaziz, Omar

    2015-01-01

    This paper uses a well-regarded, hardware based heat pump system model to investigate a two-stage economizing cycle for cold climate heat pump applications. The two-stage compression cycle has two variable-speed compressors. The high stage compressor was modelled using a compressor map, and the low stage compressor was experimentally studied using calorimeter testing. A single-stage heat pump system was modelled as the baseline. The system performance predictions are compared between the two-stage and single-stage systems. Special considerations for designing a cold climate heat pump are addressed at both the system and component levels.

  7. Side-pumping combiner for high-power fiber laser based on tandem pumping

    NASA Astrophysics Data System (ADS)

    Gu, Yanran; Lei, Chengmin; Liu, Jun; Li, Ruixian; Liu, Le; Xiao, Hu; Chen, Zilun

    2017-11-01

    We investigate a (2+1)×1 side-pumping combiner numerically and experimentally for high-power fiber laser based on tandem pumping for the first time. The influence of taper ratio and launch mode on the 1018-nm pump coupling efficiency and the leakage power into the coating of the signal fiber (LPC) is analyzed numerically. A side-pumping combiner is developed successfully by tapered-fused splicing technique based on the numerical analysis, consisting of two pump fibers (220/242 μm, NA=0.22) and a signal fiber (40/400 μm, NA=0.06/0.46). The total 1018-nm pump efficiency of the combiner is 98.1%, and the signal light insertion loss is <3%. The results show that, compared with laser diodes pumping, the combiner appears to have a better LPC performance and power handling capability when using 1018-nm fiber as the pump light. Meanwhile, an all-fiber MOPA laser based on tandem pumping with 1080-nm output of 2533 W and the slope efficiency of 82.8% is achieved based on the home-made combiner.

  8. Efficiency and threshold pump intensity of CW solar-pumped solid-state lasers

    NASA Technical Reports Server (NTRS)

    Hwang, In H.; Lee, Ja H.

    1991-01-01

    The authors consider the relation between the threshold pumping intensity, the material properties, the resonator parameters, and the ultimate slope efficiencies of various solid-state laser materials for solar pumping. They clarify the relation between the threshold pump intensity and the material parameters and the relation between the ultimate slope efficiency and the laser resonator parameters such that a design criterion for the solar-pumped solid-state laser can be established. Among the laser materials evaluated, alexandrite has the highest slope efficiency of about 12.6 percent; however, it does not seem to be practical for a solar-pumped laser application because of its high threshold pump intensity. Cr:Nd:GSGG is the most promising for solar-pumped lasing. Its threshold pump intensity is about 100 air-mass-zero (AM0) solar constants and its slope efficiency is about 12 percent when thermal deformation is completely prevented.

  9. PUMP SETS NO. 5 AND NO. 4. Each pump set ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PUMP SETS NO. 5 AND NO. 4. Each pump set consists of a Worthington Pump and a General Electric motor - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Flame Deflector Water System, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  10. Narrowband diode laser pump module for pumping alkali vapors.

    PubMed

    Rotondaro, M D; Zhdanov, B V; Shaffer, M K; Knize, R J

    2018-04-16

    We describe a method of line narrowing and frequency-locking a diode laser stack to an alkali atomic line for use as a pump module for Diode Pumped Alkali Lasers. The pump module consists of a 600 W antireflection coated diode laser stack configured to lase using an external cavity. The line narrowing and frequency locking is accomplished by introducing a narrowband polarization filter based on magneto-optical Faraday effect into the external cavity, which selectively transmits only the frequencies that are in resonance with the 6 2 S 1/2 → 6 2 P 3/2 transition of Cs atoms. The resulting pump module has demonstrated that a diode laser stack, which lases with a line width of 3 THz without narrowbanding, can be narrowed to 10 GHz. The line narrowed pump module produced 518 Watts that is 80% of the power generated by the original broadband diode laser stack.

  11. View of slow sand filters with pump house/chlorinator in foreground. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of slow sand filters with pump house/chlorinator in foreground. Clear well tank located behind pump house and trees. - Hawaii Volcanoes National Park Water Collection System, Hawaii Volcanoes National Park, Volcano, Hawaii County, HI

  12. Role of the precursor in a triple-pulse pumping scheme of a nickel-like silver soft-x-ray laser in the grazing-incidence-pumping geometry.

    PubMed

    Janulewicz, K A; Kim, C M

    2010-11-01

    Soft x-ray lasers pumped in the grazing incidence geometry show strongly reduced energetic needs but hardly changed conversion efficiency between the pump energy and the output short-wavelength radiation. Numerical analysis presented in the paper concerns with performance of a Ni-like Ag soft-x-ray laser pumped by a triple-pulse structure in the grazing incidence geometry as a function of the puming conditions. It was found that a weak precursor preceding the main preforming and heating pulses by a few nanoseconds is crucial for the energy deposition. Its presence enables in different arrangements a reasonable reduction in the pump energy and relaxation of the steep density gradients as well as a control over partition of the deposited energy. As a consequence, it was concluded that a well energetically balanced three- or multipulse composition seems to be a reasonable way to achieve performance improvement.

  13. Rovibrational optical pumping of a molecular beam

    NASA Astrophysics Data System (ADS)

    Cournol, A.; Pillet, P.; Lignier, H.; Comparat, D.

    2018-03-01

    The preparation of molecules in well-defined internal states is essential for various studies in fundamental physics and physical chemistry. It is thus of particular interest to find methods that increase the brightness of molecular beams. Here, we report on rotational and vibrational pumpings of a supersonic beam of barium monofluoride molecules. With respect to previous works, the time scale of optical vibrational pumping has been greatly reduced by enhancing the spectral power density in the vicinity of the appropriate molecular transitions. We demonstrate a complete transfer of the rovibrational populations lying in v″=1 -3 into the vibrational ground-state v″=0 . Rotational pumping, which requires efficient vibrational pumping, has been also demonstrated. According to a Maxwell-Boltzmann description, the rotational temperature of our sample has been reduced by a factor of ˜8 . In this fashion, the population of the lowest rotational levels increased by more than one order of magnitude.

  14. The IRIS Spool-Type Reactor Coolant Pump

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kujawski, J.M.; Kitch, D.M.; Conway, L.E.

    2002-07-01

    IRIS (International Reactor Innovative and Secure) is a light water cooled, 335 MWe power reactor which is being designed by an international consortium as part of the US DOE NERI Program. IRIS features an integral reactor vessel that contains all the major reactor coolant system components including the reactor core, the coolant pumps, the steam generators and the pressurizer. This integral design approach eliminates the large coolant loop piping, and thus eliminates large loss-of-coolant accidents (LOCAs) as well as the individual component pressure vessels and supports. In addition, IRIS is being designed with a long life core and enhanced safetymore » to address the requirements defined by the US DOE for Generation IV reactors. One of the innovative features of the IRIS design is the adoption of a reactor coolant pump (called 'spool' pump) which is completely contained inside the reactor vessel. Background, status and future developments of the IRIS spool pump are presented in this paper. (authors)« less

  15. Electroosmotic pump unit and assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Shaorong

    An electroosmotic pump unit includes at least a first pump element, at least a second pump element, and an electrode. Each pump element includes a tube, an electrically grounded fluid inlet, a fluid outlet electrically coupled to the electrode, and a porous monolith immobilized in the tube and having open pores having net surface charges. When the electrode applies a voltage across the monoliths, a fluid supplied to the first pump element flows through the pump elements in a direction from a fluid inlet of the first pump element toward a fluid outlet of the second pump element. A pluralitymore » of electroosmotic pump units may be connected in series in a pump assembly. The electroosmotic pump unit, or pump assembly, may be connected to an apparatus such as a HPLC.« less

  16. Mentorship for operational research capacity building: hands-on or hands-off?

    PubMed

    Harries, A D; Marais, B; Kool, B; Ram, S; Kumar, A M V; Gounder, S; Viney, K; Brostrom, R; Roseveare, C; Bissell, K; Reid, A J; Zachariah, R; Hill, P C

    2014-06-21

    Mentorship is a key feature of operational research training courses run by the International Union Against Tuberculosis and Lung Disease and Médecins Sans Frontières. During the recent South Pacific paper writing module, the faculty discussed 'hands-on' mentorship (direct technical assistance) vs. 'hands-off' mentorship (technical advice). This article explores the advantages and disadvantages of each approach. Our collective experience indicates that 'hands-on' mentorship is a valuable learning experience for the participant and a rewarding experience for the mentor. This approach increases the likelihood of successful course completion, including publishing a well written paper. However, mentors must allow participants to lead and take ownership of the paper, in keeping with a first author position.

  17. Output characteristics of a series three-port axial piston pump

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaogang; Quan, Long; Yang, Yang; Wang, Chengbin; Yao, Liwei

    2012-05-01

    Driving a hydraulic cylinder directly by a closed-loop hydraulic pump is currently a key research area in the field of electro-hydraulic control technology, and it is the most direct means to improve the energy efficiency of an electro-hydraulic control system. So far, this technology has been well applied to the pump-controlled symmetric hydraulic cylinder. However, for the differential cylinder that is widely used in hydraulic technology, satisfactory results have not yet been achieved, due to the asymmetric flow constraint. Therefore, based on the principle of the asymmetric valve controlled asymmetric cylinder in valve controlled cylinder technology, an innovative idea for an asymmetric pump controlled asymmetric cylinder is put forward to address this problem. The scheme proposes to transform the oil suction window of the existing axial piston pump into two series windows. When in use, one window is connected to the rod chamber of the hydraulic cylinder and the other is linked with a low-pressure oil tank. This allows the differential cylinders to be directly controlled by changing the displacement or rotation speed of the pumps. Compared with the loop principle of offsetting the area difference of the differential cylinder through hydraulic valve using existing technology, this method may simplify the circuits and increase the energy efficiency of the system. With the software SimulationX, a hydraulic pump simulation model is set up, which examines the movement characteristics of an individual piston and the compressibility of oil, as well as the flow distribution area as it changes with the rotation angle. The pump structure parameters, especially the size of the unloading groove of the valve plate, are determined through digital simulation. All of the components of the series arranged three distribution-window axial piston pump are designed, based on the simulation analysis of the flow pulse characteristics of the pump, and then the prototype pump is made

  18. Vectorial Command of Induction Motor Pumping System Supplied by a Photovoltaic Generator

    NASA Astrophysics Data System (ADS)

    Makhlouf, Messaoud; Messai, Feyrouz; Benalla, Hocine

    2011-01-01

    With the continuous decrease of the cost of solar cells, there is an increasing interest and needs in photovoltaic (PV) system applications following standard of living improvements. Water pumping system powered by solar-cell generators are one of the most important applications. The fluctuation of solar energy on one hand, and the necessity to optimise available solar energy on the other, it is useful to develop new efficient and flexible modes to control motors that entrain the pump. A vectorial control of an asynchronous motor fed by a photovoltaic system is proposed. This paper investigates a photovoltaic-electro mechanic chain, composed of a PV generator, DC-AC converter, a vector controlled induction motor and centrifugal pump. The PV generator is forced to operate at its maximum power point by using an appropriate search algorithm integrated in the vector control. The optimization is realized without need to adding a DC-DC converter to the chain. The motor supply is also ensured in all insolation conditions. Simulation results show the effectiveness and feasibility of such an approach.

  19. Technical Note: Approximate solution of transient drawdown for constant-flux pumping at a partially penetrating well in a radial two-zone confined aquifer

    NASA Astrophysics Data System (ADS)

    Huang, C.-S.; Yang, S.-Y.; Yeh, H.-D.

    2015-03-01

    An aquifer consisting of a skin zone and a formation zone is considered as a two-zone aquifer. Existing solutions for the problem of constant-flux pumping (CFP) in a two-zone confined aquifer involve laborious calculation. This study develops a new approximate solution for the problem based on a mathematical model including two steady-state flow equations with different hydraulic parameters for the skin and formation zones. A partially penetrating well may be treated as the Neumann condition with a known flux along the screened part and zero flux along the unscreened part. The aquifer domain is finite with an outer circle boundary treated as the Dirichlet condition. The steady-state drawdown solution of the model is derived by the finite Fourier cosine transform. Then, an approximate transient solution is developed by replacing the radius of the boundary in the steady-state solution with an analytical expression for a dimensionless time-dependent radius of influence. The approximate solution is capable of predicting good temporal drawdown distributions over the whole pumping period except at the early stage. A quantitative criterion for the validity of neglecting the vertical flow component due to a partially penetrating well is also provided. Conventional models considering radial flow without the vertical component for the CFP have good accuracy if satisfying the criterion.

  20. Effects of seasonal operation on the quality of water produced by public-supply wells

    USGS Publications Warehouse

    Bexfield, Laura M.; Jurgens, Bryant C.

    2014-01-01

    Seasonal variability in groundwater pumping is common in many places, but resulting effects of seasonal pumping stress on the quality of water produced by public-supply wells are not thoroughly understood. Analysis of historical water-quality samples from public-supply wells completed in deep basin-fill aquifers in Modesto, California (134 wells) and Albuquerque, New Mexico (95 wells) indicates that several wells have seasonal variability in concentrations of contaminants of concern. In Modesto, supply wells are more likely to produce younger groundwater with higher nitrate and uranium concentrations during the summer (high) pumping season than during the winter (low) pumping season. In Albuquerque, supply wells are more likely to produce older groundwater with higher arsenic concentrations during the winter pumping season than during the summer pumping season. Seasonal variability in contaminant concentrations in Modesto is influenced primarily by effects of summer pumping on vertical hydraulic gradients that drive migration of shallow groundwater through the aquifer to supply wells. Variability in Albuquerque is influenced primarily by the period of time that a supply well is idle, allowing its wellbore to act as a conduit for vertical groundwater flow and contaminant migration. However, both processes are observed in each study area. Similar findings would appear to be likely in other alluvial basins with stratified water quality and substantial vertical head gradients. Results suggest that even in aquifers dominated by old groundwater, changes to seasonal pumping patterns and/or to depth of well completion can help reduce vulnerability to selected contaminants of either natural or anthropogenic origin.

  1. Effects of Seasonal Operation on the Quality of Water Produced by Public-Supply Wells

    PubMed Central

    Bexfield, Laura M; Jurgens, Bryant C

    2014-01-01

    Seasonal variability in groundwater pumping is common in many places, but resulting effects of seasonal pumping stress on the quality of water produced by public-supply wells are not thoroughly understood. Analysis of historical water-quality samples from public-supply wells completed in deep basin-fill aquifers in Modesto, California (134 wells) and Albuquerque, New Mexico (95 wells) indicates that several wells have seasonal variability in concentrations of contaminants of concern. In Modesto, supply wells are more likely to produce younger groundwater with higher nitrate and uranium concentrations during the summer (high) pumping season than during the winter (low) pumping season. In Albuquerque, supply wells are more likely to produce older groundwater with higher arsenic concentrations during the winter pumping season than during the summer pumping season. Seasonal variability in contaminant concentrations in Modesto is influenced primarily by effects of summer pumping on vertical hydraulic gradients that drive migration of shallow groundwater through the aquifer to supply wells. Variability in Albuquerque is influenced primarily by the period of time that a supply well is idle, allowing its wellbore to act as a conduit for vertical groundwater flow and contaminant migration. However, both processes are observed in each study area. Similar findings would appear to be likely in other alluvial basins with stratified water quality and substantial vertical head gradients. Results suggest that even in aquifers dominated by old groundwater, changes to seasonal pumping patterns and/or to depth of well completion can help reduce vulnerability to selected contaminants of either natural or anthropogenic origin. PMID:24593780

  2. Study on dynamic characteristics of hydraulic pumping unit on offshore platform

    NASA Astrophysics Data System (ADS)

    Chang, Zong-yu; Yu, Yan-qun; Qi, Yao-guang

    2017-12-01

    A new technology of offshore oil rod pumping production is developed for offshore heavy oil recovery. A new type of miniature hydraulic pumping unit with long-stroke, low pumping speed and compact structure is designed based on the spatial characteristics of offshore platforms. By combining the strengths of sinusoidal velocity curve and trapezoidal velocity curve, a kinematical model of the acceleration, the velocity and displacement of the pumping unit's hanging point is established. The results show that the pumping unit has good kinematic characteristics of smooth motion and small dynamic load. The multi-degree-of-freedom dynamic model of the single-well pumping unit is established. The first and second order natural frequencies of the sucker rod string subsystem and the pumping unit subsystem are studied. The results show that the first and the second order natural frequencies among the pumping rod string, pumping unit-platform subsystem and the dynamic excitation have differences over 5 times from each other, indicating that resonance phenomenon will not appear during the operation and the dynamic requirements for field use are met in the system.

  3. Air-Operated Sump Pump

    NASA Technical Reports Server (NTRS)

    Nolt, Gary D.

    1988-01-01

    Pump removes liquid seepage from small, restricted area and against large pressure head. Developed for moving small amounts of water and oil from sump pit 85 ft (25.91 m) deep. Fits in space only 6 1/2 in. (16.5 cm) in diameter and 18 in. (45.7 cm) long. In discharge part of pumping cycle, air forces liquid out of pump chamber through pipe. During filling part of pumping cycle, water enters pump chamber from sump pit. Float in chamber next to pump chamber controls pressurization through timer and solenoid valve.

  4. Photovoltaic pump systems

    NASA Astrophysics Data System (ADS)

    Klockgether, J.; Kiessling, K. P.

    1983-09-01

    Solar pump systems for the irrigation of fields and for water supply in regions with much sunshine are discussed. For surface water and sources with a hoisting depth of 12 m, a system with immersion pumps is used. For deep sources with larger hoisting depths, an underwater motor pump was developed. Both types of pump system meet the requirements of simple installation and manipulation, safe operation, maintenance free, and high efficiency reducing the number of solar cells needed.

  5. Electrokinetic pump

    DOEpatents

    Patel, Kamlesh D.

    2007-11-20

    A method for altering the surface properties of a particle bed. In application, the method pertains particularly to an electrokinetic pump configuration where nanoparticles are bonded to the surface of the stationary phase to alter the surface properties of the stationary phase including the surface area and/or the zeta potential and thus improve the efficiency and operating range of these pumps. By functionalizing the nanoparticles to change the zeta potential the electrokinetic pump is rendered capable of operating with working fluids having pH values that can range from 2-10 generally and acidic working fluids in particular. For applications in which the pump is intended to handle highly acidic solutions latex nanoparticles that are quaternary amine functionalized can be used.

  6. Rotary blood pump

    NASA Astrophysics Data System (ADS)

    Bozeman, Richard J.; Akkerman, James W.; Aber, Greg S.; Vandamm, George A.; Bacak, James W.; Svejkovsky, Paul A.; Benkowski, Robert J.

    1993-11-01

    A rotary blood pump is presented. The pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial, and radial clearances of the blades associated with the flow straightener, inducer portion, impeller portion, and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with crosslinked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

  7. Rotary blood pump

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J. (Inventor); Akkerman, James W. (Inventor); Aber, Greg S. (Inventor); Vandamm, George A. (Inventor); Bacak, James W. (Inventor); Svejkovsky, Paul A. (Inventor); Benkowski, Robert J. (Inventor)

    1993-01-01

    A rotary blood pump is presented. The pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial, and radial clearances of the blades associated with the flow straightener, inducer portion, impeller portion, and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with crosslinked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

  8. Modeling of THz Lasers Based on Intersubband Transitions in Semiconductor Quantum Wells

    NASA Technical Reports Server (NTRS)

    Liu, Ansheng; Woo, Alex C. (Technical Monitor)

    1999-01-01

    In semiconductor quantum well structures, the intersubband energy separation can be adjusted to the terahertz (THz) frequency range by changing the well width and material combinations. The electronic and optical properties of these nanostructures can also be controlled by an applied dc electric field. These unique features lead to a large frequency tunability of the quantum well devices. In the on-going project of modeling of the THz lasers, we investigate the possibility of using optical pumping to generate THz radiation based on intersubband transitions in semiconductor quantum wells. We choose the optical pumping because in the electric current injection it is difficult to realize population inversion in the THz frequency range due to the small intersubband separation (4-40 meV). We considered both small conduction band offset (GaAs/AlGaAs) and large band offset (InGaAs/AlAsSb) quantum well structures. For GaAs/AlGaAs quantum wells, mid-infrared C02 lasers are used as pumping sources. For InGaAs/AlAsSb quantum wells, the resonant intersubband transitions can be excited by the near-infrared diode lasers. For three- and four-subband quantum wells, we solve the pumpfield-induced nonequilibrium distribution function for each subband of the quantum well system from a set of rate equations that include both intrasubband and intersubband relaxation processes. Taking into account the coherent interactions between pump and THz (signal) waves, we calculate the optical gain for the THz field. The gain arising from population inversion and stimulated Raman processes is calculated in a unified manner. A graph shows the calculated THz gain spectra for three-subband GaAs/AlGaAs quantum wells. We see that the coherent pump and signal wave interactions contribute significantly to the gain. The pump intensity dependence of the THz gain is also studied. The calculated results are shown. Because of the optical Stark effect and pump-induced population redistribution, the maximum

  9. Rotary piston blood pumps: past developments and future potential of a unique pump type.

    PubMed

    Wappenschmidt, Johannes; Autschbach, Rüdiger; Steinseifer, Ulrich; Schmitz-Rode, Thomas; Margreiter, Raimund; Klima, Günter; Goetzenich, Andreas

    2016-08-01

    The design of implantable blood pumps is either based on displacement pumps with membranes or rotary pumps. Both pump types have limitations to meet the clinical requirements. Rotary piston blood pumps have the potential to overcome these limitations and to merge the benefits. Compared to membrane pumps, they are smaller and with no need for wear-affected membranes and valves. Compared to rotary pumps, the blood flow is pulsatile instead of a non-physiological continuous flow. Furthermore, the risk of flow-induced blood damage and platelet activation may be reduced due to low shear stress to the blood. The past developments of rotary piston blood pumps are summarized and the main problem for long-term application is identified: insufficient seals. A new approach with seal-less drives is proposed and current research on a simplified rotary piston design is presented. Expert commentary: The development of blood pumps focuses mainly on the improvement of rotary pumps. However, medical complications indicate that inherent limitations of this pump type remain and restrict the next substantial step forward in the therapy of heart failure patients. Thus, research on different pump types is reasonable. If the development of reliable drives and bearings succeeds, rotary piston blood pumps become a promising alternative.

  10. A Passively-Suspended Tesla Pump Left Ventricular Assist Device

    PubMed Central

    Izraelev, Valentin; Weiss, William J.; Fritz, Bryan; Newswanger, Raymond K.; Paterson, Eric G.; Snyder, Alan; Medvitz, Richard B.; Cysyk, Joshua; Pae, Walter E.; Hicks, Dennis; Lukic, Branka; Rosenberg, Gerson

    2009-01-01

    The design and initial test results of a new passively suspended Tesla type LAVD blood pump are described. CFD analysis was used in the design of the pump. Overall size of the prototype device is 50 mm in diameter and 75 mm in length. The pump rotor has a density lower than that of blood and when spinning inside the stator in blood it creates a buoyant centering force that suspends the rotor in the radial direction. The axial magnetic force between the rotor and stator restrain the rotor in the axial direction. The pump is capable of pumping up to 10 liters/min at a 70 mmHg head rise at 8000 RPM. The pump has demonstrated a normalized index of hemolysis level below .02 mg/dL for flows between 2 and 9.7 L/min. An inlet pressure sensor has also been incorporated into the inlet cannula wall and will be used for control purposes. One initial in vivo study showed an encouraging result. Further CFD modeling refinements are planned as well as endurance testing of the device. PMID:19770799

  11. Temporal evolution of age data under transient pumping conditions

    NASA Astrophysics Data System (ADS)

    Leray, S.; De Dreuzy, J.; Aquilina, L.; Vergnaud, V.; Labasque, T.; Bour, O.; Le Borgne, T.

    2013-12-01

    While most age data derived from tracers have been analyzed in steady-state flow conditions, we determine their temporal evolution under transient pumping conditions. Starting pumping in a well modifies the natural flow patterns induced by the topographical gradient to a mainly convergent flow to the well. Our study is based on a set of models made up of a shallowly dipping aquifer overlain by a less permeable aquitard. These settings are characteristic of the crystalline aquifer of Plœmeur (Brittany, France) located in a highly fractured zone at the contact between a granite and micaschists. Under a pseudo steady-state flow assumption (instantaneous shift between two steady-state flow fields), we solve the transport equation with a backward particle-tracking method and determine the temporal evolution of the concentrations at the pumping well of the four atmospheric tracers CFC 11, CFC 12, CFC 113 and SF6. We show that apparent ages deduced from these concentrations evolve both because of the flow patterns modifications and because of the non-linear evolution of the atmospheric tracer concentrations. Flow patterns modifications only intervene just after the start of pumping, when the initially piston-like residence time distribution is transformed to a broader distribution mixing residence times from a wide variety of flow lines. Later, while flow patterns and the supplying volume of the pumping well still evolve, the residence time distributions are hardly modified and apparent ages are solely altered by the non-linear atmospheric tracer concentrations that progressively modifies the weighting of the residence time distribution. These results are confirmed by the observations at the site of Plœmeur in the pumping area. First, long term chloride observations confirm the quick evolution of the flow patterns after the start of pumping. Second, posterior and more recent evolutions of apparent ages derived from CFCs are consistent with the modeling results revealing

  12. A Linear Electromagnetic Piston Pump

    NASA Astrophysics Data System (ADS)

    Hogan, Paul H.

    Advancements in mobile hydraulics for human-scale applications have increased demand for a compact hydraulic power supply. Conventional designs couple a rotating electric motor to a hydraulic pump, which increases the package volume and requires several energy conversions. This thesis investigates the use of a free piston as the moving element in a linear motor to eliminate multiple energy conversions and decrease the overall package volume. A coupled model used a quasi-static magnetic equivalent circuit to calculate the motor inductance and the electromagnetic force acting on the piston. The force was an input to a time domain model to evaluate the mechanical and pressure dynamics. The magnetic circuit model was validated with finite element analysis and an experimental prototype linear motor. The coupled model was optimized using a multi-objective genetic algorithm to explore the parameter space and maximize power density and efficiency. An experimental prototype linear pump coupled pistons to an off-the-shelf linear motor to validate the mechanical and pressure dynamics models. The magnetic circuit force calculation agreed within 3% of finite element analysis, and within 8% of experimental data from the unoptimized prototype linear motor. The optimized motor geometry also had good agreement with FEA; at zero piston displacement, the magnetic circuit calculates optimized motor force within 10% of FEA in less than 1/1000 the computational time. This makes it well suited to genetic optimization algorithms. The mechanical model agrees very well with the experimental piston pump position data when tuned for additional unmodeled mechanical friction. Optimized results suggest that an improvement of 400% of the state of the art power density is attainable with as high as 85% net efficiency. This demonstrates that a linear electromagnetic piston pump has potential to serve as a more compact and efficient supply of fluid power for the human scale.

  13. Efforts to Improve Efficiency of Extraction Well Operation at the Fernald Preserve, Harrison, Ohio – 16177

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glassmeyer, Cathy; Hooten, Gwen; Hertel, Bill

    The Fernald Preserve, a former uranium processing facility that produced high-purity uranium metal products during the Cold War, is located in southwest Ohio. The facility became a US Department of Energy Office of Legacy Management (LM) site in November 2006, following completion of the Comprehensive Environmental Response, Compensation, and Liability Act environmental remediation and site restoration (with the exception of groundwater). When the site was turned over to LM, approximately 76.5 ha of the Great Miami Aquifer remained contaminated with uranium above the final remediation level of 30 μg/L. Here, uranium contamination is being removed from groundwater in the Greatmore » Miami Aquifer through a pump-and-treat operation, which is predicted to continue until 2033. Twenty extraction wells pump about 30 million liters per day. Operation of the system is impacted by iron in the groundwater that promotes iron fouling of the well pumps, motors, and screens. The design of the well field evolved over 21 years and reflected a conservative system that could respond to a wide range of pumping conditions. For instance, some of the extraction wells were sized with pumps and motors that would allow the well to pump up to 1890 L/min (500 gpm) if warranted. The added flexibility, though, came at the cost of operational efficiency. We describe the efforts that have been taken by LM since the Fernald site was transferred to LM to mitigate the operational impacts from the iron fouling aquifer conditions and improve the efficiency of the well-field operation. Variable-frequency drives were installed at six wells to replace flow control valves. Several wells with oversized pumps and motors were changed from 24-hour per day operation to 8-hour per day operation to allow the pumps to operate closer to their design flow rates. Pumps and motors were “right-sized” at many wells to improve pumping efficiency. The process used to rehabilitate (or clean) well screens was

  14. Impact of Temporally Variable and Uniform Pumping Regimes on Contaminant Transport in Heterogeneous Aquifers

    NASA Astrophysics Data System (ADS)

    Libera, A.; de Barros, F.; Guadagnini, A.

    2015-12-01

    We study and compare the effect of temporally variable and uniform pumping regimes on key features of contaminant transport in a randomly heterogeneous aquifer. Pumping wells are used for groundwater supply in the context of urban, agricultural, and industrial activities. Groundwater management agencies typically schedule groundwater extraction through a predefined sequence of pumping periods to balance benefits to anthropogenic activities and environmental needs. The impact of the spatial variability of aquifer hydraulic properties, such as hydraulic conductivity, on contaminant transport and associated solute residence times are widely studied. Only a limited number of studies address the way a given pumping schedule affects contaminant plume behavior in heterogeneous aquifers. In this context, the feedback between a transient pumping regime and contaminant breakthrough curves is largely unexplored. Our goal is to investigate the way diverse groundwater extraction strategies affect the history of solute concentration recovered at the well while accounting for the natural variability of the geological system, in the presence of incomplete information on hydraulic conductivity distribution. Considering the joint effects of spatially heterogeneous hydraulic conductivity and temporally varying well pumping rates, this work offers a realistic evaluation of groundwater contamination risk. The latter is here considered in the context of human health and is quantified in terms of the probability that harm will result from exposure to a contaminant found in groundwater. Two scenarios are considered: a pumping well that extracts a given amount of water operating (a) at a constant pumping rate and (b) under transient conditions. The analysis is performed within a numerical Monte Carlo framework. We probe the impact of diverse geostatistical structures to describe aquifer heterogeneity on solute breakthrough curves and the statistics of target environmental performance

  15. ION PUMP

    DOEpatents

    Milleron, N.

    1961-01-01

    An ion pump and pumping method are given for low vacuum pressures in which gases introduced into a pumping cavity are ionized and thereafter directed and accelerated into a quantity of liquid gettering metal where they are absorbed. In the preferred embodiment the metal is disposed as a liquid pool upon one electrode of a Phillips ion gauge type pump. Means are provided for continuously and remotely withdrawing and degassing the gettering metal. The liquid gettering metal may be heated if desired, although various combinations of gallium, indium, tin, bismuth, and lead, the preferred metals, have very low melting points. A background pressure of evaporated gettering metal may be provided by means of a resistance heated refractory metal wick protruding from the surface of the pcol of gettering metal.

  16. Increasing pumping efficiency in a micro throttle pump by enhancing displacement amplification in an elastomeric substrate

    NASA Astrophysics Data System (ADS)

    Fujiwara, T.; Johnston, I. D.; Tracey, M. C.; Tan, C. K. L.

    2010-06-01

    Fluid transport is accomplished in a micro throttle pump (MTP) by alternating deformation of a micro channel cast into a polydimethylsiloxane (PDMS) elastomeric substrate. The active deformation is achieved using a bimorph PZT piezoelectric disc actuator bonded to a glass diaphragm. The bimorph PZT deflects the diaphragm as well as alternately pushing and pulling the elastomer layer providing displacement amplification in the PDMS directly surrounding the micro channel. In order to improve pumping rates we have embedded a polymethylmethacrylate (PMMA) ring into the PMDS substrate which increases the magnitude of the displacement amplification achieved. FEM simulation of the elastomeric substrate deformation predicts that the inclusion of the PMMA ring should increase the channel deformation. We experimentally demonstrate that inclusion of a PMMA ring, having a diameter equal to that of the circular node of the PZT/glass/PDMS composite, increases in the throttle resistance ratio by 40% and the maximum pumping rate by 90% compared to an MTP with no ring.

  17. Liquid metal enabled pump

    PubMed Central

    Tang, Shi-Yang; Khoshmanesh, Khashayar; Sivan, Vijay; Petersen, Phred; O’Mullane, Anthony P.; Abbott, Derek; Mitchell, Arnan; Kalantar-zadeh, Kourosh

    2014-01-01

    Small-scale pumps will be the heartbeat of many future micro/nanoscale platforms. However, the integration of small-scale pumps is presently hampered by limited flow rate with respect to the input power, and their rather complicated fabrication processes. These issues arise as many conventional pumping effects require intricate moving elements. Here, we demonstrate a system that we call the liquid metal enabled pump, for driving a range of liquids without mechanical moving parts, upon the application of modest electric field. This pump incorporates a droplet of liquid metal, which induces liquid flow at high flow rates, yet with exceptionally low power consumption by electrowetting/deelectrowetting at the metal surface. We present theory explaining this pumping mechanism and show that the operation is fundamentally different from other existing pumps. The presented liquid metal enabled pump is both efficient and simple, and thus has the potential to fundamentally advance the field of microfluidics. PMID:24550485

  18. A review of selected pumping systems in nature and engineering--potential biomimetic concepts for improving displacement pumps and pulsation damping.

    PubMed

    Bach, D; Schmich, F; Masselter, T; Speck, T

    2015-09-03

    The active transport of fluids by pumps plays an essential role in engineering and biology. Due to increasing energy costs and environmental issues, topics like noise reduction, increase of efficiency and enhanced robustness are of high importance in the development of pumps in engineering. The study compares pumps in biology and engineering and assesses biomimetic potentials for improving man-made pumping systems. To this aim, examples of common challenges, applications and current biomimetic research for state-of-the art pumps are presented. The biomimetic research is helped by the similar configuration of many positive displacement pumping systems in biology and engineering. In contrast, the configuration and underlying pumping principles for fluid dynamic pumps (FDPs) differ to a greater extent in biology and engineering. However, progress has been made for positive displacement as well as for FDPs by developing biomimetic devices with artificial muscles and cilia that improve energetic efficiency and fail-safe operation or reduce noise. The circulatory system of vertebrates holds a high biomimetic potential for the damping of pressure pulsations, a common challenge in engineering. Damping of blood pressure pulsation results from a nonlinear viscoelastic behavior of the artery walls which represent a complex composite material. The transfer of the underlying functional principle could lead to an improvement of existing technical solutions and be used to develop novel biomimetic damping solutions. To enhance efficiency or thrust of man-made fluid transportation systems, research on jet propulsion in biology has shown that a pulsed jet can be tuned to either maximize thrust or efficiency. The underlying principle has already been transferred into biomimetic applications in open channel water systems. Overall there is a high potential to learn from nature in order to improve pumping systems for challenges like the reduction of pressure pulsations, increase of jet

  19. Mentorship for operational research capacity building: hands-on or hands-off?

    PubMed Central

    Marais, B.; Kool, B.; Ram, S.; Kumar, A. M. V.; Gounder, S.; Viney, K.; Brostrom, R.; Roseveare, C.; Bissell, K.; Reid, A. J.; Zachariah, R.; Hill, P. C.

    2014-01-01

    Mentorship is a key feature of operational research training courses run by the International Union Against Tuberculosis and Lung Disease and Médecins Sans Frontières. During the recent South Pacific paper writing module, the faculty discussed ‘hands-on’ mentorship (direct technical assistance) vs. ‘hands-off’ mentorship (technical advice). This article explores the advantages and disadvantages of each approach. Our collective experience indicates that ‘hands-on’ mentorship is a valuable learning experience for the participant and a rewarding experience for the mentor. This approach increases the likelihood of successful course completion, including publishing a well written paper. However, mentors must allow participants to lead and take ownership of the paper, in keeping with a first author position. PMID:26477290

  20. Kaiser Permanente National Hand Hygiene Program

    PubMed Central

    Barnes, Sue; Barron, Dana; Becker, Linda; Canola, Teresa; Salemi, Charles

    2004-01-01

    Objective: Hand hygiene has historically been identified as an important intervention for preventing infection acquired in health care settings. Recently, the advent of waterless, alcohol-based skin degermer and elimination of artificial nails have been recognized as other important interventions for preventing infection. Supplied with this information, the National Infection Control Peer Group convened a KP Hand Hygiene Work Group, which, in August 2001, launched a National Hand Hygiene Program initiative titled “Infection Control: It’s In Our Hands” to increase compliance with hand hygiene throughout the Kaiser Permanente (KP) organization. Design: The infection control initiative was designed to include employee and physician education as well as to implement standard hand hygiene products (eg, alcohol degermers), eliminate use of artificial nails, and monitor outcomes. Results: From 2001 through September 2003, the National KP Hand Hygiene Work Group coordinated implementation of the Hand Hygiene initiative throughout the KP organization. To date, outcome monitoring has shown a 26% increase in compliance with hand hygiene as well as a decrease in the number of bloodstream infections and methycillin-resistant Staphylococcus aureus (MRSA) infections. As of May 2003, use of artificial nails had been reduced by 97% nationwide. Conclusions: Endorsement of this Hand Hygiene Program initiative by KP leadership has led to implementation of the initiative at all medical centers throughout the KP organization. Outcome indicators to date suggest that the initiative has been successful; final outcome monitoring will be completed in December 2003. PMID:26704605

  1. 20. ENGINE/PUMP HOUSE EXTENSION, PUMP NO. 4, HOUSING FOR ECCENTRICS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. ENGINE/PUMP HOUSE EXTENSION, PUMP NO. 4, HOUSING FOR ECCENTRICS THAT CONTROL THE STEAM FOR EAST PISTON LOCATED BELOW THE PISTON CRANKSHAFT HUB AND ABOVE THE THRUST BEARING; CONTROL RODS FOR PISTON NO. 3 LOCATED AT RIGHT. - Deer Island Pumping Station, Boston, Suffolk County, MA

  2. 25. Hot well, as seen from port side aft. Waste ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. Hot well, as seen from port side aft. Waste water overflow pipe appears at left, behind which is bilge pump. At base of hot well on either side are reciprocating boiler feedwater pumps driven from hot well crosshead. (Labels were applied by HAER recording team and are not original to equipment.) - Steamboat TICONDEROGA, Shelburne Museum Route 7, Shelburne, Chittenden County, VT

  3. Measure Guideline: Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunt, A.; Easley, S.

    2012-05-01

    The report evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provide a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  4. Diode-pumped laser with improved pumping system

    DOEpatents

    Chang, Jim J.

    2004-03-09

    A laser wherein pump radiation from laser diodes is delivered to a pump chamber and into the lasing medium by quasi-three-dimensional compound parabolic concentrator light channels. The light channels have reflective side walls with a curved surface and reflective end walls with a curved surface. A flow tube between the lasing medium and the light channel has a roughened surface.

  5. Hazardous Chemical Pump Tests.

    DTIC Science & Technology

    1980-07-01

    hydraulic flow rate is the product of the pump speed and the pump displacement. The pump displacement for each respective pump was constant throughout...speed - rpm T - torque - ft lbs 7= 3.1416 By substituting the product of pump speed and pump displacement for the hydraulic flow rate (Q=NO) in the above...FF:iipr’: iL 40 H FLUID F-’UMPED; FPl H FVIi T’E1l ’HJO I...S Lu FL: H KFITE C F~~:ri FIGURE 2 CC E MT 2, Fi C F . c ;E’C F11 *:;_cl PF fog O ~ \\ 4 1

  6. Radial flow to a partially penetrating well with storage in an anisotropic confined aquifer

    NASA Astrophysics Data System (ADS)

    Mishra, Phoolendra Kumar; Vesselinov, Velimir V.; Neuman, Shlomo P.

    2012-07-01

    SummaryDrawdowns generated by extracting water from large diameter (e.g. water supply) well are affected by wellbore storage. We present an analytical solution in Laplace transformed space for drawdown in a uniform anisotropic aquifer caused by withdrawing water at a constant rate from partially penetrating well with storage. The solution is back transformed into the time domain numerically. When the pumping well is fully penetrating our solution reduces to that of Papadopulos and Cooper (1967); Hantush (1964) when the pumping well has no wellbore storage; Theis (1935) when both conditions are fulfilled and Yang (2006) when the pumping well is partially penetrating, has finite radius but lacks storage. Newly developed solution is then used to explore graphically the effects of partial penetration, wellbore storage and anisotropy on time evolutions of drawdown in the pumping well and in observation wells. We concluded after validating the developed analytical solution using synthetic pumping test.

  7. Direct solar pumping of semiconductor lasers: A feasibility study

    NASA Technical Reports Server (NTRS)

    Anderson, Neal G.

    1992-01-01

    This report describes results of NASA Grant NAG-1-1148, entitled Direct Solar Pumping of Semiconductor Lasers: A Feasibility Study. The goals of this study were to provide a preliminary assessment of the feasibility of pumping semiconductor lasers in space with directly focused sunlight and to identify semiconductor laser structures expected to operate at the lowest possible focusing intensities. It should be emphasized that the structures under consideration would provide direct optical-to-optical conversion of sunlight into laser light in a single crystal, in contrast to a configuration consisting of a solar cell or storage battery electrically pumping a current injection laser. With external modulation, such lasers could perhaps be efficient sources for intersatellite communications. We proposed specifically to develop a theoretical model of semiconductor quantum-well lasers photopumped by a broadband source, test it against existing experimental data where possible, and apply it to estimating solar pumping requirements and identifying optimum structures for operation at low pump intensities. These tasks have been accomplished, as described in this report of our completed project. The report is organized as follows: Some general considerations relevant to the solar-pumped semiconductor laser problem are discussed in Section 2, and the types of structures chosen for specific investigation are described. The details of the laser model we developed for this work are then outlined in Section 3. In Section 4, results of our study are presented, including designs for optimum lattice-matched and strained-layer solar-pumped quantum-well lasers and threshold pumping estimates for these structures. It was hoped at the outset of this work that structures could be identified which could be expected to operate continuously at solar photoexcitation intensities of several thousand suns, and this indeed turned out to be the case as described in this section. Our project is

  8. Measure Guideline. Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunt, A.; Easley, S.

    2012-05-01

    This measure guideline evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provides a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  9. Electromagnetic liquid pistons for capillarity-based pumping.

    PubMed

    Malouin, Bernard A; Vogel, Michael J; Olles, Joseph D; Cheng, Lili; Hirsa, Amir H

    2011-02-07

    The small scales associated with lab-on-a-chip technologies lend themselves well to capillarity-dominated phenomena. We demonstrate a new capillarity-dominated system where two adjoining ferrofluid droplets can behave as an electronically-controlled oscillator or switch by an appropriate balance of magnetic, capillary, and inertial forces. Their oscillatory motion can be exploited to displace a surrounding liquid (akin to an axial piston pump), forming electromagnetic "liquid pistons." Such ferrofluid pistons can pump a precise volume of liquid via finely tunable amplitudes (cf. pump stroke) or resonant frequencies (cf. pump speed) with no solid moving parts for long-term operation without wear in a small device. Furthermore, the rapid propagation of electromagnetic fields and the favorable scaling of capillary forces with size permit micron sized devices with very fast operating speeds (∼kHz). The pumping dynamics and performance of these liquid pistons is explored, with experimental measurements showing good agreement with a spherical cap model. While these liquid pistons may find numerous applications in micro- and mesoscale fluidic devices (e.g., remotely activated drug delivery), here we demonstrate the use of these liquid pistons in capillarity-dominated systems for chip-level, fast-acting adaptive liquid lenses with nearly perfect spherical interfaces.

  10. Contributing recharge areas to water-supply wells at Wright-Patterson Air Force Base, Ohio

    USGS Publications Warehouse

    Sheets, R.A.

    1994-01-01

    Wright-Patterson Air Force Base, in southwestern Ohio, has operated three well fields--Area B, Skeel Road, and the East Well Fields--to supply potable water for consumption and use for base activities. To protect these well fields from contamination and to comply with the Ohio Wellhead Protection Plan, the Base is developing a wellhead-protection program for the well fields. A three-dimensional, steady-state ground-water-flow model was developed in 1993 to simulate heads in (1) the buried-valley aquifer system that is tapped by the two active well fields, and in (2) an upland bedrock aquifer that may supply water to the wells. An advective particle-tracking algorithm that requires estimated porosities and simulated heads was used to estimate ground-water-flow pathlines and traveltimes to the active well fields. Contributing recharge areas (CRA's)--areas on the water table that contribute water to a well or well field--were generated for 1-, 5-, and 10-year traveltimes. Results from the simulation and subsequent particle tracking indicate that the CRA's for the Skeel Road Well Fields are oval and extend north- ward, toward the Mad River, as pumping at the well field increases. The sizes of the 1-, 5-, and 10-year CRA's of Skeel Road Well Field, under maximum pumping conditions, are approximately 0.5, 1.5 and 3.2 square miles, respectively. The CRA's for the Area B Well Field extend to the north, up the Mad River Valley; as pumping increases at the well field, the CRA's extend up the Mad River Valley under Huffman Dam. The sizes of the 1-, 5-, and 10-year CRA's of Area B Well Field, under maximum pumping conditions, are approximately 0.1, 0.5, and 0.9 square miles, respectively. The CRA's for the East Well Field are affected by nearby streams under average pumping conditions. The sizes of the 1-, 5-, and 10-year CRA's of the East Well Field, under maximum pumping conditions, are approximately 0.2, 1.2, and 2.4 square miles, respectively. However, as pumping increases

  11. Warming of infusion syringes caused by electronic syringe pumps.

    PubMed

    Cornelius, A; Frey, B; Neff, T A; Gerber, A C; Weiss, M

    2003-05-01

    To evaluate inadvertent warming of the infusion syringe in four different types of electronic syringe pumps. Ambient temperature and syringe surface temperature were simultaneously measured by two electronic temperature probes in four different models of commercially available syringe pumps. Experiments were performed at an infusion rate of 1 ml h(-1) using both battery-operated and main power-operated pumps. Measurements were repeated four times with two pumps from each of the four syringe pump types at a room temperature of approximately 23 degrees C. Differences among the four syringe pump brands regarding ambient to syringe temperature gradient were compared using ANOVA. A P-value of less than 0.05 was considered statistically significant. Syringe warming differed significantly between the four syringe brands for both the battery-operated and main power-operated mode (ANOVA, P< 0.001 for both modes). Individual differences between syringe surface and ambient temperature ranged from 0.3 to 1.9 degrees C for battery operation and from 0.5 to 11.2 degrees C during main-power operation. Infusion solutions can be significantly warmed by syringe pumps. This has potential impact on bacterial growth and the stability of drug solutions and blood products infused, as well as on the susceptibility to hydrostatic pressure changes within the infusion syringe.

  12. Quantifying the energy required for groundwater pumping across a regional aquifer system

    NASA Astrophysics Data System (ADS)

    Ronayne, M. J.; Shugert, D. T.

    2017-12-01

    Groundwater pumping can be a substantial source of energy expenditure, particularly in semiarid regions with large depths to water. In this study we assessed the energy required for groundwater pumping in the Denver Basin aquifer system, a group of sedimentary rock aquifers used for municipal water supply in Colorado. In recent decades, declining water levels in the Denver Basin aquifers has resulted in increased pumping lifts and higher energy use rates. We quantified the spatially variable energy intensity for groundwater pumping by analyzing spatial variations in the lift requirement. The median energy intensities for two major aquifers were 1.2 and 1.8 kWh m-3. Considering typical municipal well production rates and household water use in the study area, these results indicate that the energy cost associated with groundwater pumping can be a significant fraction (>20%) of the total electricity consumption for all household end uses. Pumping at this scale (hundreds of municipal wells producing from deep aquifers) also generates substantial greenhouse gas emissions. Analytical wellfield modeling conducted as part of this study clearly demonstrates how multiple components of the lift impact the energy requirement. Results provide guidance for water management strategies that reduce energy expenditure.

  13. An Energy Saving System for a Beam Pumping Unit

    PubMed Central

    Lv, Hongqiang; Liu, Jun; Han, Jiuqiang; Jiang, An

    2016-01-01

    Beam pumping units are widely used in the oil production industry, but the energy efficiency of this artificial lift machinery is generally low, especially for the low-production well and high-production well in the later stage. There are a number of ways for energy savings in pumping units, with the periodic adjustment of stroke speed and rectification of balance deviation being two important methods. In the paper, an energy saving system for a beam pumping unit (ESS-BPU) based on the Internet of Things (IoT) was proposed. A total of four types of sensors, including load sensor, angle sensor, voltage sensor, and current sensor, were used to detect the operating conditions of the pumping unit. Data from these sensors was fed into a controller installed in an oilfield to adjust the stroke speed automatically and estimate the degree of balance in real-time. Additionally, remote supervision could be fulfilled using a browser on a computer or smartphone. Furthermore, the data from a practical application was recorded and analyzed, and it can be seen that ESS-BPU is helpful in reducing energy loss caused by unnecessarily high stroke speed and a poor degree of balance. PMID:27187402

  14. Resonantly diode-pumped Er:YAG laser: 1470-nm versus 1530-nm CW pumping case

    NASA Astrophysics Data System (ADS)

    Kudryashov, Igor; Ter-Gabrielyan, Nikolai; Dubinskii, Mark

    2009-05-01

    Growing interest to high power lasers in the eye-safe spectral domain initiated a new wave of activity in developing solid-state lasers based on bulk Er3+-doped materials. The resonant pumping of SSL allows for shifting significant part of thermal load from gain medium itself to the pump diodes, thus greatly reducing gain medium thermal distortions deleterious to SSL power scaling with high beam quality. The two major resonant pumping bands in Er:YAG are centered around 1470 and 1532 nm. Pumping into each of these bands has its pros and contras. The best approach to resonant pumping of Er:YAG active media in terms of pump wavelength is yet to be determined. We report the investigation results of high power diode-pumped Er:YAG laser aimed at direct comparison of resonant pumping at 1470 and 1532 nm. Two sources used for pumping were: 1530-nm 10-diode bar stack (>300 W CW) and 1470-nm 10-diode bar stack (>650 W CW). Both pumps were spectrally narrowed by external volume Bragg gratings. The obtained spectral width of less than 1 nm allowed for 'in-line' pumping of Er3+ in either band. The obtained CW power of over 87 W is, to the best of our knowledge, the record high power reported for resonantly pumped Er:YAG DPSSL at room temperature.

  15. Types of Breast Pumps

    MedlinePlus

    ... nipple (the areola). b. Pump: creates the gentle vacuum that expresses milk. The pump may be attached to the breast-shield or ... out of a larger tube to create a vacuum that expresses milk and collects it in an attached container. Another type of manual pump, called a bicycle horn pump, consists of a ...

  16. Enzyme-Powered Pumps: From Fundamentals to Applications

    NASA Astrophysics Data System (ADS)

    Ortiz-Rivera, Isamar

    Non-mechanical nano and microfluidic devices that function without the aid of an external power source, and can be tailored to meet specific needs, represent the next generation of smart devices. Recently, we have shown that surface-bound enzymes can act as pumps driving large-scale fluid flows in the presence of any substance that triggers the enzymatic reaction (e.g. substrate, co-factor, or biomarker). The fluid velocities attained in such systems depend directly on the enzymatic reaction rate and the concentration of the substance that initiates enzymatic catalysis. The use of biochemical reactions to power a micropump offers the advantages of specificity, sensitivity, and selectively, eliminating at the same time the need of an external power source, while providing biocompatibility. More importantly, these self-powered pumps overcome a significant obstacle in nano- and micro-fluidics: the need to use external pressure-driven pumps to push fluids through devices. Certainly, the development of enzyme-powered devices opens up new venues in biochemical engineering, particularly in the biomedical field. The work highlighted in this dissertation covers all the studies performed with enzyme-powered pumps, from the development of the micropump design, to the efforts invested in understanding the enzyme pump concept as a whole. The data collected to date, aims to expand our knowledge about enzyme-powered micropumps from the inside out: not only by exploring the different applications of these devices at the macroscale, but also by investigating in depth the mechanism of pump activation behind these systems. Specifically, we have focused on: (1) The general features that characterize the pumping behavior observed in enzyme-powered pumps, as well as the optimization of the device, (2) the possible mechanisms behind fluid motion, including the role of enzyme coverage and/or activity on the transduction of chemical energy into mechanical fluid flow in these devices

  17. SHINE Vacuum Pump Test Verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morgan, Gregg A; Peters, Brent

    2013-09-30

    Normetex pumps used world-wide for tritium service are no longer available. DOE and other researchers worldwide have spent significant funds characterizing this pump. Identification of alternate pumps is required for performance and compatibility with tritium gas. Many of the pumps that could be used to meet the functional performance requirements (e.g. pressure and flow conditions) of the Normetex pump have features that include the use of polymers or oils and greases that are not directly compatible with tritium service. This study assembles a test system to determine the flow characteristics for candidate alternate pumps. These tests are critical to themore » movement of tritium through the SHINE Tritium Purification System (TPS). The purpose of the pump testing is two-fold: (1) obtain baseline vacuum pump characteristics for an alternate (i.e. ''Normetex replacement'') pump intended for use in tritium service; and (2) verify that low pressure hydrogen gas can be transported over distances up to 300 feet by the candidate pumps. Flow rates and nominal system pressures have been identified for the SHINE Mo-99 production process Tritium Purification System (TPS). To minimize the line sizes for the transfer of low pressure tritium from the Neutron Driver Accelerator System (NDAS) to the primary processing systems in the TPS, a ''booster'' pump has been located near the accelerator in the design. A series of pump tests were performed at various configurations using hydrogen gas (no tritium) to ensure that this concept is practical and maintains adequate flow rates and required pressures. This report summarizes the results of the tests that have been performed using various pump configurations. The current design of the Tritium Purification System requires the ''booster'' pump to discharge to or to be backed by another vacuum pump. Since Normetex pumps are no longer manufactured, a commercially available Edwards scroll pump will be used to back the booster pump. In

  18. Effects of seasonal operation on the quality of water produced by public-supply wells.

    PubMed

    Bexfield, Laura M; Jurgens, Bryant C

    2014-09-01

    Seasonal variability in groundwater pumping is common in many places, but resulting effects of seasonal pumping stress on the quality of water produced by public-supply wells are not thoroughly understood. Analysis of historical water-quality samples from public-supply wells completed in deep basin-fill aquifers in Modesto, California (134 wells) and Albuquerque, New Mexico (95 wells) indicates that several wells have seasonal variability in concentrations of contaminants of concern. In Modesto, supply wells are more likely to produce younger groundwater with higher nitrate and uranium concentrations during the summer (high) pumping season than during the winter (low) pumping season. In Albuquerque, supply wells are more likely to produce older groundwater with higher arsenic concentrations during the winter pumping season than during the summer pumping season. Seasonal variability in contaminant concentrations in Modesto is influenced primarily by effects of summer pumping on vertical hydraulic gradients that drive migration of shallow groundwater through the aquifer to supply wells. Variability in Albuquerque is influenced primarily by the period of time that a supply well is idle, allowing its wellbore to act as a conduit for vertical groundwater flow and contaminant migration. However, both processes are observed in each study area. Similar findings would appear to be likely in other alluvial basins with stratified water quality and substantial vertical head gradients. Results suggest that even in aquifers dominated by old groundwater, changes to seasonal pumping patterns and/or to depth of well completion can help reduce vulnerability to selected contaminants of either natural or anthropogenic origin. Published 2014. This article is a U.S. Government work and is in the public domain in the USA. Groundwater published by Wiley Periodicals, Inc. on behalf of National Ground Water Association.

  19. Oil/gas separator for installation at burning wells

    DOEpatents

    Alonso, C.T.; Bender, D.A.; Bowman, B.R.; Burnham, A.K.; Chesnut, D.A.; Comfort, W.J. III; Guymon, L.G.; Henning, C.D.; Pedersen, K.B.; Sefcik, J.A.; Smith, J.A.; Strauch, M.S.

    1993-03-09

    An oil/gas separator is disclosed that can be utilized to return the burning wells in Kuwait to production. Advantageously, a crane is used to install the separator at a safe distance from the well. The gas from the well is burned off at the site, and the oil is immediately pumped into Kuwait's oil gathering system. Diverters inside the separator prevent the oil jet coming out of the well from reaching the top vents where the gas is burned. The oil falls back down, and is pumped from an annular oil catcher at the bottom of the separator, or from the concrete cellar surrounding the well.

  20. Oil/gas separator for installation at burning wells

    DOEpatents

    Alonso, Carol T.; Bender, Donald A.; Bowman, Barry R.; Burnham, Alan K.; Chesnut, Dwayne A.; Comfort, III, William J.; Guymon, Lloyd G.; Henning, Carl D.; Pedersen, Knud B.; Sefcik, Joseph A.; Smith, Joseph A.; Strauch, Mark S.

    1993-01-01

    An oil/gas separator is disclosed that can be utilized to return the burning wells in Kuwait to production. Advantageously, a crane is used to install the separator at a safe distance from the well. The gas from the well is burned off at the site, and the oil is immediately pumped into Kuwait's oil gathering system. Diverters inside the separator prevent the oil jet coming out of the well from reaching the top vents where the gas is burned. The oil falls back down, and is pumped from an annular oil catcher at the bottom of the separator, or from the concrete cellar surrounding the well.

  1. 11. PUMP HOUSE AND WEIGHING ROOM Fish were pumped from ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. PUMP HOUSE AND WEIGHING ROOM Fish were pumped from floating hoppers, to the pump house (on the far right). From there they were either lifted by conveyor belt to the weighing room (top center) and thence to the holding tanks, or were washed through sealers, weighed and then sluiced to holding tanks. The process used depended upon the type and size of fish. The square cement vat (center) was to be a settling tank from which fish oil, reclaimed from the reduction process, was to be pumped into the round metal tank (above the vat). This process however, was never fully utilized before the sardines ran out. - Hovden Cannery, 886 Cannery Row, Monterey, Monterey County, CA

  2. Research on solar pumped liquid lasers

    NASA Technical Reports Server (NTRS)

    Schneider, R. T.; Kurzweg, U. H.; Cox, J. D.; Weinstein, N. H.

    1983-01-01

    A solar pumped liquid laser that can be scaled up to high power (10Mw CW) for space applications was developed. Liquid lasers have the inherent advantage over gases in that they provide much higher lasant densities and thus high power densities. Liquids also have inherent advantages over solids in that they have much higher damage thresholds and are much cheaper to produce for large scale applications. Among the liquid laser media that are potential candidates for solar pumping, the POC13:Nd(3+):ZrC14 liquid was chosen for its high intrinsic efficiency as well as its relatively good stability against decomposition due to protic contamination. The development and testing of the laser liquid and the development of a large solar concentrator to pump the laser was emphasized. The procedure to manufacture the laser liquid must include diagnostic tests of the solvent purity (from protic contamination) at various stages in the production process.

  3. Smart Markets for Transferable Pumping Rights

    NASA Astrophysics Data System (ADS)

    Brozovic, N.; Young, R.

    2016-12-01

    While no national policy on groundwater use exists in the United States, local groundwater management is emerging across the country in response to concerns and conflicts over declining well yields, land subsidence, and the depletion of hydrologically connected surface waters. Management strategies include well drilling moratoria, pumping restrictions, and restrictions on the expansion of irrigated land. To provide flexibility to groundwater users, local regulatory authorities increasingly have begun to allow the transfer of groundwater rights as a cost-effective management tool. Markets can be a versatile risk management tool, helping communities to cope with scarcity, to meet goals for sustainability, and to grow resilient local economies. For example, active groundwater rights transfers exist in the High Plains region of the United States. Yet, several barriers to trade exist: high search costs for interested parties, complicated requirements for regulatory compliance, and reluctance to share sensitive financial information. Additionally, groundwater pumping leads to several kinds of spatial and intertemporal externalities such as stream depletion. Indeed, groundwater management schemes that reallocate water between alternate pumping locations are often explicitly designed to change the distribution and magnitude of pumping externalities. Reallocation may be designed to minimize unwanted impacts on third parties or to encourage trades that reduce the magnitude of externalities. We discuss how smart markets can deal with complex biophysical constraints while also encouraging active trading, therefore ensuring local goals for aquifer sustainability while growing local economies. Smart markets address these issues by providing a centralized hub for trading, automating the process of regulatory compliance by only matching buyers and sellers eligible to trade as specified in the regulations, and maintaining anonymous, confidential bidding.

  4. Rotary Blood Pump

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor); Akkerman, James W. (Inventor); Aber, Gregory S. (Inventor); VanDamm, George A. (Inventor); Bacak, James W. (Inventor); Svejkovsky, Paul A. (Inventor); Benkowski, Robert J. (Inventor)

    1996-01-01

    A rotary blood pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial and radial clearances of blades associated with the flow straightener, inducer portion, impeller portion and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with cross-linked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

  5. Assessment of the quality of water from hand-dug wells in ghana.

    PubMed

    Nkansah, Marian Asantewah; Boadi, Nathaniel Owusu; Badu, Mercy

    2010-04-26

    This study focused upon the determination of physicochemical and microbial properties, including metals, selected anions and coliform bacteria in drinking water samples from hand-dug wells in the Kumasi metropolis of the Republic of Ghana. The purpose was to assess the quality of water from these sources. Ten different water samples were taken from different parts of Kumasi, the capital of the Ashanti region of Ghana and analyzed for physicochemical parameters including pH, electrical conductivity, total dissolved solids, alkalinity total hardness and coliform bacteria. Metals and anions analyzed were Ca, Mg, Fe, Mn, NO(3) (-), NO(2) (-), SO(4) (2-), PO(4) (2-), F(-) and Cl(-). Bacteria analysed were total coliform and Escherichia coli.THE DATA SHOWED VARIATION OF THE INVESTIGATED PARAMETERS IN SAMPLES AS FOLLOWS: pH, 6.30-0.70; conductivity (EC), 46-682 muS/cm; PO(4) (3-), 0.67-76.00 mg/L; F(-), 0.20-0.80 mg/L; NO(3) (-), 0-0.968 mg/L; NO(2) (-), 0-0.063 mg/L; SO(4) (2-), 3.0-07.0 mg/L; Fe, 0-1.2 mg/L; Mn, 0-0.018 mg/L. Total coliform and Escherichia coli were below the minimum detection limit (MDL) of 20 MPN per 100 ml in all the samples. The concentrations of most of the investigated parameters in the drinking water samples from Ashanti region were within the permissible limits of the World Health Organization drinking water quality guidelines.

  6. The Proton Pump Inhibitor Nonresponder: a Behavioral Approach to Improvement and Wellness.

    PubMed

    Riehl, Megan E; Chen, Joan W

    2018-06-09

    Gastroesophageal reflux disease (GERD) is a difficult to treat medical condition, where nearly 40% of patients are refractory to standard medical intervention, which typically begins with a proton pump inhibitor (PPI). These PPI nonresponders represent a population of patients, where treatment planning must be individualized; multidisciplinary and psychiatric comorbidities should be considered. This review highlights treatment options that include neuromodulators, lifestyle, and psychological interventions for the PPI nonresponder. Mental health specialists in the field of psychogastroenterology can aid in the management of esophageal hypersensitivity, which can drive the symptom experience of a PPI nonresponder. Considerations for comorbid anxiety and depression in this population require careful assessment and treatment. Physicians are encouraged to create realistic expectations for symptom management and offer multidisciplinary options for treatment early in care. Patients will frequently benefit from working with a GI psychologist and find value in behavioral interventions.

  7. A pump monitoring approach to irrigation pumping plant testing

    USDA-ARS?s Scientific Manuscript database

    The conventional approach for evaluating irrigation pumping plant performance has been an instantaneous spot measurement approach. Using this method, the tester measures the necessary work and energy use parameters to determine overall pumping plant performance. The primary limitation of this appr...

  8. Semiconductor Laser Diode Pumps for Inertial Fusion Energy Lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deri, R J

    2011-01-03

    reductions and increased reliability. The high-level requirements on the semiconductor lasers involve reliability, price points on a price-per-Watt basis, and a set of technical requirements. The technical requirements for the amplifier design in reference 1 are discussed in detail and are summarized in Table 1. These values are still subject to changes as the overall laser system continues to be optimized. Since pump costs can be a significant fraction of the overall laser system cost, it is important to achieve sufficiently low price points for these components. At this time, the price target for tenth-of-akind IFE plant is $0.007/Watt for packaged devices. At this target level, the pumps account for approximately one third of the laser cost. The pump lasers should last for the life of the power plant, leading to a target component lifetime requirement of roughly 14 Ghosts, corresponding to a 30 year plant life and 15 Hz repetition rate. An attractive path forward involes pump operation at high output power levels, on a Watts-per-bar (Watts/chip) basis. This reduces the cost of pump power (price-per-Watt), since to first order the unit price does not increase with power/bar. The industry has seen a continual improvement in power output, with current 1 cm-wide bars emitting up to 500 W QCW (quasi-continuous wave). Increased power/bar also facilitates achieving high irradiance in the array plane. On the other hand, increased power implies greater heat loads and (possibly) higher current drive, which will require increased attention to thermal management and parasitic series resistance. Diode chips containing multiple p-n junctions and quantum wells (also called nanostack structures) may provide an additional approach to reduce the peak current.« less

  9. Improvement of centrifugal pump performance through addition of splitter blades on impeller pump

    NASA Astrophysics Data System (ADS)

    Kurniawan, Krisna Eka; Santoso, Budi; Tjahjana, Dominicus Danardono Dwi Prija

    2018-02-01

    The workable way to improve pump performance is to redesign or modify the impellers of centrifugal pump. The purpose of impeller pump modification is to improve pump efficiency, reduce cross flow, reduce secondary incidence flows, and decrease backflow areas at impeller outlets. Number blades and splitter blades in the impeller are three. The outlet blade angle is 20°, and the rotating speed of impeller is 2400 rpm. The added splitter blades variations are 0.25, 0.375, and 0.5 of the original blade length. The splitter blade placements are on the outer side of the impeller. The addition of splitter blades on the outer side of the impeller with 0.5L increases the pump head until 22% and the pump has 38.66% hydraulic efficiency. The best efficiency point of water flow rate pump (Qbep) was 3.02 × 10-3 m3/s.

  10. Early outcomes of on-pump versus off-pump coronary artery bypass grafting.

    PubMed

    Hussain, Ghulam; Azam, Hammad; Baig, Mirza Ahmad Raza; Ahmad, Naseem

    2016-01-01

    To see the early post-operative outcomes of off-pump versus on-pump coronary artery bypass graft surgery. This retrospective analytical study was conducted at Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Our Primary outcome variables were; necessity of inotropic support, nonfatal myocardial infarction, ICU stay, nonfatal stroke, new renal failure requiring dialysis and death within 30 days after operation. There were two groups of patients; Group-I (On-pump group) and Group-II (Off-pump Group). SPSS V17 was used for data analysis. Independent sample t-test and Mann Whitney U test were used to compare quantitative Variables. Chi-square test and Fisher's exact test were used to analyze qualitative variables. P-value ≤ 0.05 was considered significant. Three hundred patients were included in this study. There were no significant difference regarding risk factors except hyper-cholestrolemia which was high in off pump group (p-value 0.05). Angiographic and Echocardiographic characteristics e.g. preoperative ejection fraction, LV function grade and severity of CAD was same between the groups. Mortality risk scores and Priority status for surgery were also same. Regarding post-operative outcomes; Post-op CKMB Levels, need and duration of inotropic support, mechanical ventilation time and ICU stay was significantly less in Off-Pump group (p-value 0.001, <0.0001, 0.006, 0.025 and 0.001 resp.). Peri-operative chest drainage was significantly high in On-pump CABG group (p-value 0.027). Incidence of post-op complications was not statistically different between the groups. At 30 days follow-up, Incidence of myocardial infarction, necessity and duration of inotropic support, ICU stay period and peri-operative bleeding were significantly less in off-pump group. The incidence of neurologic, pulmonary and renal complications was same between the off-pump and on-pump groups.

  11. Early outcomes of on-pump versus off-pump coronary artery bypass grafting

    PubMed Central

    Hussain, Ghulam; Azam, Hammad; Baig, Mirza Ahmad Raza; Ahmad, Naseem

    2016-01-01

    Objectives: To see the early post-operative outcomes of off-pump versus on-pump coronary artery bypass graft surgery. Methods: This retrospective analytical study was conducted at Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Our Primary outcome variables were; necessity of inotropic support, nonfatal myocardial infarction, ICU stay, nonfatal stroke, new renal failure requiring dialysis and death within 30 days after operation. There were two groups of patients; Group-I (On-pump group) and Group-II (Off-pump Group). SPSS V17 was used for data analysis. Independent sample t-test and Mann Whitney U test were used to compare quantitative Variables. Chi-square test and Fisher’s exact test were used to analyze qualitative variables. P-value ≤ 0.05 was considered significant. Results: Three hundred patients were included in this study. There were no significant difference regarding risk factors except hyper-cholestrolemia which was high in off pump group (p-value 0.05). Angiographic and Echocardiographic characteristics e.g. preoperative ejection fraction, LV function grade and severity of CAD was same between the groups. Mortality risk scores and Priority status for surgery were also same. Regarding post-operative outcomes; Post-op CKMB Levels, need and duration of inotropic support, mechanical ventilation time and ICU stay was significantly less in Off-Pump group (p-value 0.001, <0.0001, 0.006, 0.025 and 0.001 resp.). Peri-operative chest drainage was significantly high in On-pump CABG group (p-value 0.027). Incidence of post-op complications was not statistically different between the groups. Conclusions: At 30 days follow-up, Incidence of myocardial infarction, necessity and duration of inotropic support, ICU stay period and peri-operative bleeding were significantly less in off-pump group. The incidence of neurologic, pulmonary and renal complications was same between the off-pump and on-pump groups. PMID:27648039

  12. Simulated effects of Lower Floridan aquifer pumping on the Upper Floridan aquifer at Pooler, Chatham County, Georgia

    USGS Publications Warehouse

    Cherry, Gregory S.; Clarke, John S.

    2013-01-01

    A revised regional groundwater-flow model was used to assess the potential effects on the Upper Floridan aquifer (UFA) of pumping the Lower Floridan aquifer (LFA) from a new well (35Q069) located at the City of Pooler in coastal Georgia near Savannah. The spatial resolution of the original regional, steady-state, groundwater-flow model was increased to incorporate detailed hydrogeologic information resulting from field investigations at Pooler and existing wells in the area. Simulation results using the U.S. Geological Survey finite-difference code MODFLOW indicated that long-term pumping at a rate of 780 gallons per minute (gal/min) from the LFA well 35Q069 would cause a maximum drawdown of about 2.52 feet (ft) in the UFA (scenario A). This maximum drawdown in the UFA was greater than the observed draw-down of 0.9 ft in the 72-hour aquifer test, but this is expected because the steady-state simulated drawdown represents long-term pumping conditions. Model results for scenario A indicate that drawdown in the UFA exceeded 1 ft over a 163-square-mile (mi2) area. Induced vertical leakage from the UFA provided about 98 percent of the water to the LFA; the area within 1 mile of the pumped well contributed about 81 percent of the water pumped. Simulated pumping changed regional water-budget components slightly and redistributed flow among model layers, namely increasing downward leakage in all layers, decreasing upward leakage in all layers above the LFA, increasing inflow to and decreasing outflow from lateral specified-head boundaries in the UA and LFA, and increasing the volume of induced recharge from the general head boundary to outcrop units. An additional two groundwater-pumping scenarios were run to establish that a linear relation exists between pumping rates of the LFA well 35Q069 (varied from 390 to 1,042 gal/min) and amount of drawdown in the UFA and LFA. Three groundwater-pumping scenarios were run to evaluate the amount of UFA pumping (128 to 340 gal

  13. Influence of In-Well Convection on Well Sampling

    USGS Publications Warehouse

    Vroblesky, Don A.; Casey, Clifton C.; Lowery, Mark A.

    2006-01-01

    Convective transport of dissolved oxygen (DO) from shallow to deeper parts of wells was observed as the shallow water in wells in South Carolina became cooler than the deeper water in the wells due to seasonal changes. Wells having a relatively small depth to water were more susceptible to thermally induced convection than wells where the depth to water was greater because the shallower water levels were more influenced by air temperature. The potential for convective transport of DO to maintain oxygenated conditions in a well was diminished as ground-water exchange through the well screen increased and as oxygen demand increased. Convective flow did not transport oxygen to the screened interval when the screened interval was deeper than the range of the convective cell. The convective movement of water in wells has potential implications for passive, or no-purge, and low-flow sampling approaches. Transport of DO to the screened interval can adversely affect the ability of passive samplers to produce accurate concentrations of oxygen-sensitive solutes, such as iron. Other potential consequences include mixing the screened-interval water with casing water and potentially allowing volatilization loss at the water surface. A field test of diffusion samplers in a convecting well during the winter, however, showed good agreement of chlorinated solvent concentrations with pumped samples, indicating that there was no negative impact of the convection on the utility of the samplers to collect volatile organic compound concentrations in that well. In the cases of low-flow sampling, convective circulation can cause the pumped sample to be a mixture of casing water and aquifer water. This can substantially increase the equilibration time of oxygen as an indicator parameter and can give false indications of the redox state. Data from this investigation show that simple in-well devices can effectively mitigate convective transport of oxygen. The devices can range from

  14. Bull heading to kill live gas wells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oudeman, P.; Avest, D. ter; Grodal, E.O.

    1994-12-31

    To kill a live closed-in gas well by bull heading down the tubing, the selected pump rate should be high enough to ensure efficient displacement of the gas into the formation (i.e., to avoid the kill fluid bypassing the gas). On the other hand, the pressures that develop during bull heading at high rate must not exceed wellhead pressure rating, tubing or casing burst pressures or the formation breakdown gradient, since this will lead, at best, to a very inefficient kill job. Given these constraints, the optimum kill rate, requited hydraulic horsepower, density and type of kill fluids have tomore » be selected. For this purpose a numerical simulator has been developed, which predicts the sequence of events during bull heading. Pressures and flow rates in the well during the kill job are calculated, taking to account slip between the gas and kill fluid, hydrostatic and friction pressure drop, wellbore gas compression and leak-off to the formation. Comparison with the results of a dedicated field test demonstrates that these parameters can be estimated accurately. Example calculations will be presented to show how the simulator can be used to identify an optimum kill scenario.« less

  15. Fuel pumping system and method

    DOEpatents

    Shafer, Scott F [Morton, IL; Wang, Lifeng ,

    2006-12-19

    A fuel pumping system that includes a pump drive is provided. A first pumping element is operatively connected to the pump drive and is operable to generate a first flow of pressurized fuel. A second pumping element is operatively connected to the pump drive and is operable to generate a second flow of pressurized fuel. A first solenoid is operatively connected to the first pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the first flow of pressurized fuel. A second solenoid is operatively connected to the second pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the second flow of pressurized fuel.

  16. Fuel Pumping System And Method

    DOEpatents

    Shafer, Scott F.; Wang, Lifeng

    2005-12-13

    A fuel pumping system that includes a pump drive is provided. A first pumping element is operatively connected to the pump drive and is operable to generate a first flow of pressurized fuel. A second pumping element is operatively connected to the pump drive and is operable to generate a second flow of pressurized fuel. A first solenoid is operatively connected to the first pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the first flow of pressurized fuel. A second solenoid is operatively connected to the second pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the second flow of pressurized fuel.

  17. Phosphate-core silica-clad Er/Yb-doped optical fiber and cladding pumped laser.

    PubMed

    Egorova, O N; Semjonov, S L; Velmiskin, V V; Yatsenko, Yu P; Sverchkov, S E; Galagan, B I; Denker, B I; Dianov, E M

    2014-04-07

    We present a composite optical fiber with a Er/Yb co-doped phosphate-glass core in a silica glass cladding as well as cladding pumped laser. The fabrication process, optical properties, and lasing parameters are described. The slope efficiency under 980 nm cladding pumping reached 39% with respect to the absorbed pump power and 28% with respect to the coupled pump power. Due to high doping level of the phosphate core optimal length was several times shorter than that of silica core fibers.

  18. Submersible sodium pump

    DOEpatents

    Brynsvold, Glen V.; Lopez, John T.; Olich, Eugene E.; West, Calvin W.

    1989-01-01

    An electromagnetic submerged pump has an outer cylindrical stator with an inner cylindrical conductive core for the submerged pumping of sodium in the cylindrical interstitial volume defined between the stator and core. The cylindrical interstitial volume is typically vertically oriented, and defines an inlet at the bottom and an outlet at the top. The outer stator generates upwardly conveyed toroidal magnetic fields, which fields convey preferably from the bottom of the pump to the top of the pump liquid sodium in the cold leg of a sodium cooled nuclear reactor. The outer cylindrical stator has a vertically disposed duct surrounded by alternately stacked layers of coil units and laminates.

  19. Submersible sodium pump

    DOEpatents

    Brynsvold, G.V.; Lopez, J.T.; Olich, E.E.; West, C.W.

    1989-11-21

    An electromagnetic submerged pump has an outer cylindrical stator with an inner cylindrical conductive core for the submerged pumping of sodium in the cylindrical interstitial volume defined between the stator and core. The cylindrical interstitial volume is typically vertically oriented, and defines an inlet at the bottom and an outlet at the top. The outer stator generates upwardly conveyed toroidal magnetic fields, which fields convey preferably from the bottom of the pump to the top of the pump liquid sodium in the cold leg of a sodium cooled nuclear reactor. The outer cylindrical stator has a vertically disposed duct surrounded by alternately stacked layers of coil units and laminates. 14 figs.

  20. Electroosmotic pumps and their applications in microfluidic systems

    PubMed Central

    Wang, Xiayan; Cheng, Chang; Wang, Shili; Liu, Shaorong

    2009-01-01

    Electroosmotic pumping is receiving increasing attention in recent years owing to the rapid development in micro total analytical systems. Compared with other micropumps, electroosmotic pumps (EOPs) offer a number of advantages such as creation of constant pulse-free flows and elimination of moving parts. The flow rates and pumping pressures of EOPs matches well with micro analysis systems. The common materials and fabrication technologies make it readily integrateable with lab-on-a-chip devices. This paper reviews the recent progress on EOP fabrications and applications in order to promote the awareness of EOPs to researchers interested in using micro- and nano-fluidic devices. The pros and cons of EOPs are also discussed, which helps these researchers in designing and constructing their micro platforms. PMID:20126306

  1. Coordination of hand shape.

    PubMed

    Pesyna, Colin; Pundi, Krishna; Flanders, Martha

    2011-03-09

    The neural control of hand movement involves coordination of the sensory, motor, and memory systems. Recent studies have documented the motor coordinates for hand shape, but less is known about the corresponding patterns of somatosensory activity. To initiate this line of investigation, the present study characterized the sense of hand shape by evaluating the influence of differences in the amount of grasping or twisting force, and differences in forearm orientation. Human subjects were asked to use the left hand to report the perceived shape of the right hand. In the first experiment, six commonly grasped items were arranged on the table in front of the subject: bottle, doorknob, egg, notebook, carton, and pan. With eyes closed, subjects used the right hand to lightly touch, forcefully support, or imagine holding each object, while 15 joint angles were measured in each hand with a pair of wired gloves. The forces introduced by supporting or twisting did not influence the perceptual report of hand shape, but for most objects, the report was distorted in a consistent manner by differences in forearm orientation. Subjects appeared to adjust the intrinsic joint angles of the left hand, as well as the left wrist posture, so as to maintain the imagined object in its proper spatial orientation. In a second experiment, this result was largely replicated with unfamiliar objects. Thus, somatosensory and motor information appear to be coordinated in an object-based, spatial-coordinate system, sensitive to orientation relative to gravitational forces, but invariant to grasp forcefulness.

  2. Liquid metal electric pump

    DOEpatents

    Abbin, J.P.; Andraka, C.E.; Lukens, L.L.; Moreno, J.B.

    1992-01-14

    An electrical pump for pumping liquid metals to high pressures in high temperature environments without the use of magnets or moving mechanical parts. The pump employs a non-porous solid electrolyte membrane, typically ceramic, specific to the liquid metal to be pumped. A DC voltage is applied across the thickness of the membrane causing ions to form and enter the membrane on the electrically positive surface, with the ions being neutralized on the opposite surface. This action provides pumping of the liquid metal from one side of the non-porous solid electrolyte membrane to the other. 3 figs.

  3. Liquid metal electric pump

    DOEpatents

    Abbin, Joseph P.; Andraka, Charles E.; Lukens, Laurance L.; Moreno, James B.

    1992-01-01

    An electrical pump for pumping liquid metals to high pressures in high temperature environments without the use of magnets or moving mechanical parts. The pump employs a non-porous solid electrolyte membrane, typically ceramic, specific to the liquid metal to be pumped. A DC voltage is applied across the thickness of the membrane causing ions to form and enter the membrane on the electrically positive surface, with the ions being neutralized on the opposite surface. This action provides pumping of the liquid metal from one side of the non-porous solid electrolyte membrane to the other.

  4. Park size and disturbance: impact on soil heterogeneity - a case study Tel-Aviv- Jaffa.

    NASA Astrophysics Data System (ADS)

    Zhevelev, Helena; Sarah, Pariente; Oz, Atar

    2015-04-01

    Parks and gardens are poly-functional elements of great importance in urban areas, and can be used for optimization of physical and social components in these areas. This study aimed to investigate alteration of soil properties with land usages within urban park and with area size of park. Ten parks differed by size (2 - 50 acres) were chosen, in random, in Tel-Aviv- Jaffa city. Soil was sampled in four microenvironments ((lawn, path, picnic and peripheral area (unorganized area) of each the park)), in three points and three depth (0-2, 5-10 and 10-20 cm). Penetration depth was measured in all point of sampling. For each soil sample electrical conductivity and organic matter content were determined. Averages of penetration depth drastically increased from the most disturbed microenvironments (path and picnic) to the less disturbed ones (lawn and peripheral). The maximal heterogeneity (by variances and percentiles) of penetration depth was found in the peripheral area. In this area, penetration depth increased with increasing park size, i.e., from 2.6 cm to 3.7 cm in the small and large parks, respectively. Averages of organic matter content and electrical conductivity decreased with soil depth in all microenvironments and increased with decreasing disturbance of microenvironments. Maximal heterogeneity for both of these properties was found in the picnic area. Increase of park size was accompanied by increasing of organic matter content in the upper depth in the peripheral area, i.e., from 2.4% in the small parks to 4.5% in the large ones. In all microenvironments the increasing of averages of all studied soil properties was accompanied by increasing heterogeneity, i.e., variances and upper percentiles. The increase in the heterogeneity of the studied soil properties is attributed to improved ecological soil status in the peripheral area, on the one hand, and to the high anthropogenic pressure in the picnic area, on the other. This means that the urban park offers

  5. [Complex trauma of the hand].

    PubMed

    Pechlaner, S; Hussl, H

    1998-01-01

    The hand is very exposed to injuries in the daily man's work. The multiple functions of the hand are based on vitality, sensibility, motor function and stability. In severe hand injuries the functional results of the repair are often very poor. In a complex injury of the hand we are faced with the damage of the soft tissue and bone and the loss of vitality and function of the hand. The cause of hand injuries are mainly a crush trauma or the rotating saw. Basically, we recommend an extended primary repair. After the radical debridement we have to reconstruct the damaged structures. We start doing the osteosynthesis and stabilization of the joints. Thereafter, suturing of extensor and flexor tendons. Then, we do the microsurgical reconstructions of vessels and nerves. In case tendons and bones are exposed we have to cover the defect with a pedicled or a free flap. In a long ischemic time we have to change our concept and do the reconstruction of the vessels first. Our results in vitality and sensibility are listed. In the result of a complex hand injury each single functional restoration is very important. Therefore, it is necessary that severe hand injuries are treated at well established centres for hand surgery.

  6. Geothermal Heat Pump Basics | NREL

    Science.gov Websites

    a free source of hot water. Geothermal heat pumps use much less energy than conventional heating resources: Geothermal Heat Pumps U.S. Department of Energy's Office of Energy Efficiency and Renewable Heat Pump Basics Geothermal Heat Pump Basics Geothermal heat pumps take advantage of the nearly

  7. Advanced high-temperature electromagnetic pump

    NASA Technical Reports Server (NTRS)

    Gahan, J. W.; Powell, A. H.

    1972-01-01

    Three phase helical, electromagnetic induction pump for use as boiler feed pump in potassium Rankine-cycle power system is described. Techniques for fabricating components of pump are discussed. Specifications of pump are analyzed.

  8. Pump polarization insensitive and efficient laser-diode pumped Yb:KYW ultrafast oscillator.

    PubMed

    Wang, Sha; Wang, Yan-Biao; Feng, Guo-Ying; Zhou, Shou-Huan

    2016-02-01

    We theoretically and experimentally report and evaluate a novel split laser-diode (LD) double-end pumped Yb:KYW ultrafast oscillator aimed at improving the performance of an ultrafast laser. Compared to a conventional unpolarized single-LD end-pumped ultrafast laser system, we improve the laser performance such as absorption efficiency, slope efficiency, cw mode-locking threshold, and output power by this new structure LD-pumped Yb:KYW ultrafast laser. Experiments were carried out with a 1 W output fiber-coupled LD. Experimental results show that the absorption increases from 38.7% to 48.4%, laser slope efficiency increases from 18.3% to 24.2%, cw mode-locking threshold decreases 12.7% from 630 to 550 mW in cw mode-locking threshold, and maximum output-power increases 28.5% from 158.4 to 221.5 mW when we switch the pump scheme from an unpolarized single-end pumping structure to a split LD double-end pumping structure.

  9. Gas-heat-pump development

    NASA Astrophysics Data System (ADS)

    Creswick, F. A.

    Incentives for the development of gas heat pumps are discussed. Technical progress made on several promising technologies was reviewed. The status of development of gas-engine-driven heat pumps, the absorption cycle for the near- and long-term gas heat pump systems, the Stirling engine, the small Rankine-cycle engines, and gas-turbine-driven heat pump systems were briefly reviewed. Progress in the US, Japan, and Europe is noted.

  10. Factors associated with combined hand and foot eczema.

    PubMed

    Agner, T; Aalto-Korte, K; Andersen, K E; Foti, C; Gimenéz-Arnau, A; Goncalo, M; Goossens, A; Le Coz, C; Diepgen, T L

    2017-05-01

    As for hand eczema, the aetiology of foot eczema is multifactorial and not very well understood. The aim of the present study was to identify factors associated with foot eczema in a cohort of hand eczema patients being classified into different subgroups. Associations between foot and hand eczema were studied in a cross-sectional design in a cohort of hand eczema patients. Consecutive patients were recruited from nine different European Centres during the period October 2011-September 2012. Data on demographic factors, presence of foot eczema, hand eczema duration and severity, and whether the hand eczema was work-related or not were available, as well as patch-test results. Of a total of 427 hand eczema patients identified, information on foot eczema was available in 419 patients who were included in the present study. A total of 125 patients (29.8%) had concomitant foot and hand eczema. It was found more often in association with hyperkeratotic hand eczema (P = 0.007) and was less often associated with irritant hand eczema (P < 0.001). However, foot eczema was nevertheless found in 18% of patient with irritant hand eczema and in 25% of patients with occupational hand eczema. Combined foot and hand eczema was associated with more severe and long-standing hand eczema (P < 0.001 and P = 0.004, respectively). Contact allergy was found in 51.8% with no difference between patients with combined foot and hand eczema and patients with hand eczema only. Occurrence of combined foot and hand eczema is a common finding and not restricted to endogenous hand eczema. © 2016 European Academy of Dermatology and Venereology.

  11. Peristaltic pump-based low range pressure sensor calibration system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vinayakumar, K. B.; Department of Electronic Systems Engineering, Indian Institute of Science, Bangalore 5600012; Naveen Kumar, G.

    2015-11-15

    Peristaltic pumps were normally used to pump liquids in several chemical and biological applications. In the present study, a peristaltic pump was used to pressurize the chamber (positive as well negative pressures) using atmospheric air. In the present paper, we discuss the development and performance study of an automatic pressurization system to calibrate low range (millibar) pressure sensors. The system includes a peristaltic pump, calibrated pressure sensor (master sensor), pressure chamber, and the control electronics. An in-house developed peristaltic pump was used to pressurize the chamber. A closed loop control system has been developed to detect and adjust the pressuremore » leaks in the chamber. The complete system has been integrated into a portable product. The system performance has been studied for a step response and steady state errors. The system is portable, free from oil contaminants, and consumes less power compared to existing pressure calibration systems. The veracity of the system was verified by calibrating an unknown diaphragm based pressure sensor and the results obtained were satisfactory.« less

  12. Peristaltic pump-based low range pressure sensor calibration system

    NASA Astrophysics Data System (ADS)

    Vinayakumar, K. B.; Naveen Kumar, G.; Nayak, M. M.; Dinesh, N. S.; Rajanna, K.

    2015-11-01

    Peristaltic pumps were normally used to pump liquids in several chemical and biological applications. In the present study, a peristaltic pump was used to pressurize the chamber (positive as well negative pressures) using atmospheric air. In the present paper, we discuss the development and performance study of an automatic pressurization system to calibrate low range (millibar) pressure sensors. The system includes a peristaltic pump, calibrated pressure sensor (master sensor), pressure chamber, and the control electronics. An in-house developed peristaltic pump was used to pressurize the chamber. A closed loop control system has been developed to detect and adjust the pressure leaks in the chamber. The complete system has been integrated into a portable product. The system performance has been studied for a step response and steady state errors. The system is portable, free from oil contaminants, and consumes less power compared to existing pressure calibration systems. The veracity of the system was verified by calibrating an unknown diaphragm based pressure sensor and the results obtained were satisfactory.

  13. 2 kW pump-light-stripper-free distributed side-coupled cladding-pumped fiber oscillator

    NASA Astrophysics Data System (ADS)

    Ying, Hanyuan; Yu, Yu; Cao, Jianqiu; Huang, Zhihe; Pan, Zhiyong; Wang, Zefeng; Chen, Jinbao

    2017-06-01

    A 2 kW pump-light-stripper-free all-fiber distributed-pumping oscillator fabricated with the distributed side-coupled cladding-pumped Yb-doped fiber is demonstrated for the first time, to the best of our knowledge. An output power of 1969 W with a slope efficiency of 72.2% is obtained. By utilizing the final-section counter-pumping scheme, pure output spectra free from residual pump light are obtained without using any pump light stripper, which demonstrates that the pump light stripper is not indispensable for this configuration. Besides, no stimulated Raman scattering component is observed in the output spectra. The laser has the M 2 factor ranging from 2.0 to 2.6. We believe that the pertinent results are helpful and valuable for designing high-power fiber laser systems.

  14. Pumps for microfluidic cell culture.

    PubMed

    Byun, Chang Kyu; Abi-Samra, Kameel; Cho, Yoon-Kyoung; Takayama, Shuichi

    2014-02-01

    In comparison to traditional in vitro cell culture in Petri dishes or well plates, cell culture in microfluidic-based devices enables better control over chemical and physical environments, higher levels of experimental automation, and a reduction in experimental materials. Over the past decade, the advantages associated with cell culturing in microfluidic-based platforms have garnered significant interest and have led to a plethora of studies for high throughput cell assays, organs-on-a-chip applications, temporal signaling studies, and cell sorting. A clear concern for performing cell culture in microfluidic-based devices is deciding on a technique to deliver and pump media to cells that are encased in a microfluidic device. In this review, we summarize recent advances in pumping techniques for microfluidic cell culture and discuss their advantages and possible drawbacks. The ultimate goal of our review is to distill the large body of information available related to pumps for microfluidic cell culture in an effort to assist current and potential users of microfluidic-based devices for advanced in vitro cellular studies. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Inhibitors of Proton Pumping

    PubMed Central

    Bisson, Mary A.

    1986-01-01

    Reported inhibitors of the Characean plasmalemma proton pump were tested for their ability to inhibit the passive H+ conductance which develops in Chara corallina Klein ex Willd. at high pH. Diethylstilbestrol inhibits the proton pump and the passive H+ conductance with about the same time course, at concentrations that have no effect on cytoplasmic streaming. N-Ethylmaleimide, a sulfhydryl reagent which is small and relatively nonpolar, also inhibits both pumping and passive conductance of H+. However, it also inhibits cytoplasmic streaming with about the same time course, and therefore could not be considered a specific ATPase inhibitor. p-Chloromercuribenzene sulfonate (PCMBS), a sulfhydryl reagent which is large and charged and hence less able to penetrate the membrane, does not inhibit pumping or conductance at low concentration. At high concentration, PCMBS sometimes inhibits pumping without affecting H+ conductance, but since streaming is also inhibited, the effect on the pump cannot be said to be specific. 1-Ethyl-3-(3-dimethylaminopropyl)carbodiimide, a water soluble carbodiimide, weakly inhibits both pump and conductance, apparently specifically. PMID:16664807

  16. Transient well flow in layered aquifer systems: the uniform well-face drawdown solution

    NASA Astrophysics Data System (ADS)

    Hemker, C. J.

    1999-11-01

    Previously a hybrid analytical-numerical solution for the general problem of computing transient well flow in vertically heterogeneous aquifers was proposed by the author. The radial component of flow was treated analytically, while the finite-difference technique was used for the vertical flow component only. In the present work the hybrid solution has been modified by replacing the previously assumed uniform well-face gradient (UWG) boundary condition in such a way that the drawdown remains uniform along the well screen. The resulting uniform well-face drawdown (UWD) solution also includes the effects of a finite diameter well, wellbore storage and a thin skin, while partial penetration and vertical heterogeneity are accommodated by the one-dimensional discretization. Solutions are proposed for well flow caused by constant, variable and slug discharges. The model was verified by comparing wellbore drawdowns and well-face flux distributions with published numerical solutions. Differences between UWG and UWD well flow will occur in all situations with vertical flow components near the well, which is demonstrated by considering: (1) partially penetrating wells in confined aquifers, (2) fully penetrating wells in unconfined aquifers with delayed response and (3) layered aquifers and leaky multiaquifer systems. The presented solution can be a powerful tool for solving many well-hydraulic problems, including well tests, flowmeter tests, slug tests and pumping tests. A computer program for the analysis of pumping tests, based on the hybrid analytical-numerical technique and UWG or UWD conditions, is available from the author.

  17. Jet pump assisted artery

    NASA Technical Reports Server (NTRS)

    1975-01-01

    A procedure for priming an arterial heat pump is reported; the procedure also has a means for maintaining the pump in a primed state. This concept utilizes a capillary driven jet pump to create the necessary suction to fill the artery. Basically, the jet pump consists of a venturi or nozzle-diffuser type constriction in the vapor passage. The throat of this venturi is connected to the artery. Thus vapor, gas, liquid, or a combination of the above is pumped continuously out of the artery. As a result, the artery is always filled with liquid and an adequate supply of working fluid is provided to the evaporator of the heat pipe.

  18. A qualitative analysis of the experience and impact of killing in hand-to-hand combat.

    PubMed

    Jensen, Peter R; Simpson, Duncan

    2014-08-01

    A growing body of research suggests that killing during military combat is closely associated with posttraumatic stress disorder (PTSD), as well as a number of other adverse mental health related conditions (e.g., dissociative experiences, violent behavior, functional impairment). This article provides first-person perspectives on the experiences and impact of killing by service members with the goal of expanding our understanding of the impact of taking a life during war. In audio-recorded phenomenological interviews, 9 service members described their experiences and the subsequent impact of killing during hand-to-hand combat. A description, supported by participant quotations, was constructed to represent the participants' experiences. Results suggest the experience and aftermath of taking a life in hand-to-hand combat was disturbing, psychologically stressful, and necessitated some form of coping after the event. Service members who killed in hand-to-hand combat viewed their actions as necessary to preserve their life and that killing in hand-to-hand combat was more emotionally taxing than killing by shooting. Our findings may help to improve providers' understanding of service members' first-person experiences of killing in hand-to-hand combat and thus provide the basis for the development of a connected and genuine relationship with such military clients. Copyright © 2014 International Society for Traumatic Stress Studies.

  19. Impulse Pump

    DTIC Science & Technology

    2016-06-17

    APPLICATIONS [0002] None. BACKGROUND OF THE INVENTION (1) Field of the Invention [0003] The present invention relates to an impulse pump for generating...impulse pump 15. The sleeve bearings 98 are affixed to the head block 90 to ease axial motion while the plunger 72 is under torsional loads. [0041

  20. Accuracy of a New Patch Pump Based on a Microelectromechanical System (MEMS) Compared to Other Commercially Available Insulin Pumps

    PubMed Central

    Borot, Sophie; Franc, Sylvia; Cristante, Justine; Penfornis, Alfred; Benhamou, Pierre-Yves; Guerci, Bruno; Hanaire, Hélène; Renard, Eric; Reznik, Yves; Simon, Chantal

    2014-01-01

    The JewelPUMP™ (JP) is a new patch pump based on a microelectromechanical system that operates without any plunger. The study aimed to evaluate the infusion accuracy of the JP in vitro and in vivo. For the in vitro studies, commercially available pumps meeting the ISO standard were compared to the JP: the MiniMed® Paradigm® 712 (MP), Accu-Chek® Combo (AC), OmniPod® (OP), Animas® Vibe™ (AN). Pump accuracy was measured over 24 hours using a continuous microweighing method, at 0.1 and 1 IU/h basal rates. The occlusion alarm threshold was measured after a catheter occlusion. The JP, filled with physiological serum, was then tested in 13 patients with type 1 diabetes simultaneously with their own pump for 2 days. The weight difference was used to calculate the infused insulin volume. The JP showed reduced absolute median error rate in vitro over a 15-minute observation window compared to other pumps (1 IU/h): ±1.02% (JP) vs ±1.60% (AN), ±1.66% (AC), ±2.22% (MP), and ±4.63% (OP), P < .0001. But there was no difference over 24 hours. At 0.5 IU/h, the JP was able to detect an occlusion earlier than other pumps: 21 (19; 25) minutes vs 90 (85; 95), 58 (42; 74), and 143 (132; 218) minutes (AN, AC, MP), P < .05 vs AN and MP. In patients, the 24-hour flow error was not significantly different between the JP and usual pumps (–2.2 ± 5.6% vs –0.37 ± 4.0%, P = .25). The JP was found to be easier to wear than conventional pumps. The JP is more precise over a short time period, more sensitive to catheter occlusion, well accepted by patients, and consequently, of potential interest for a closed-loop insulin delivery system. PMID:25079676

  1. Solar system design for water pumping

    NASA Astrophysics Data System (ADS)

    Abdelkader, Hadidi; Mohammed, Yaichi

    2018-05-01

    In our days, it seems to us that nobody can suspect it on the importance of water and energy for the human needs. With technological advances, the energy need does not cease increasing. This problem of energy is even more sensitive in the isolated sites where the use of the traditional resources proves often very expensive. Indeed, several constraints, like the transport of fuel and the routine maintenances of the diesel engines, return the search for an essential alternative energy source for this type of sites. It summer necessary to seek other resources of energy of replacement. Renewable energies, like photovoltaic energy, wind or hydraulic, represent a replacement solution par excellence and they are used more and more in our days more especially as the national territory has one of the solar layers highest with the world. The duration of insolation can reach the 3900 hours/year on the Sahara. The energy acquired daily on a horizontal surface of 1m2 is about 5kWh, that is to say meadows of 2263kWh/m2/year in the south of the country. The photovoltaic energy utilization for pumping of water is well adapted for more the share of the arid and semi-arid areas because of the existence in these areas of an underground hydraulic potential not very major. Another very important coincidence supports the use of this type of energy for the water pumping is that the demand for water, especially in agriculture, reached its maximum in hot weather and dryness where it is precisely the moment when one has access to the maximum of solar energy. The goal to see an outline on the general composition of a photovoltaic system of pumping, as well as the theoretical elements making it possible to dimension the current pumping stations.

  2. Microchip solid-state cylindrical vector lasers with orthogonally polarized dual laser-diode end pumping.

    PubMed

    Otsuka, Kenju; Chu, Shu-Chun

    2013-05-01

    We report a simple method for generating cylindrical vector beams directly from laser-diode (LD)-pumped microchip solid-state lasers by using dual end-pumping beams. Radially as well as azimuthally polarized vector field emissions have been generated from the common c-cut Nd:GdVO4 laser cavity merely by controlling the focus positions of orthogonally polarized LD off-axis pump beams. Hyperbolically polarized vector fields have also been observed, in which the cylindrical symmetry of vector fields is broken. Experimental results have been well reproduced by numerical simulations.

  3. Dual-wavelength pump-probe microscopy analysis of melanin composition

    NASA Astrophysics Data System (ADS)

    Thompson, Andrew; Robles, Francisco E.; Wilson, Jesse W.; Deb, Sanghamitra; Calderbank, Robert; Warren, Warren S.

    2016-11-01

    Pump-probe microscopy is an emerging technique that provides detailed chemical information of absorbers with sub-micrometer spatial resolution. Recent work has shown that the pump-probe signals from melanin in human skin cancers correlate well with clinical concern, but it has been difficult to infer the molecular origins of these differences. Here we develop a mathematical framework to describe the pump-probe dynamics of melanin in human pigmented tissue samples, which treats the ensemble of individual chromophores that make up melanin as Gaussian absorbers with bandwidth related via Frenkel excitons. Thus, observed signals result from an interplay between the spectral bandwidths of the individual underlying chromophores and spectral proximity of the pump and probe wavelengths. The model is tested using a dual-wavelength pump-probe approach and a novel signal processing method based on gnomonic projections. Results show signals can be described by a single linear transition path with different rates of progress for different individual pump-probe wavelength pairs. Moreover, the combined dual-wavelength data shows a nonlinear transition that supports our mathematical framework and the excitonic model to describe the optical properties of melanin. The novel gnomonic projection analysis can also be an attractive generic tool for analyzing mixing paths in biomolecular and analytical chemistry.

  4. Dual-wavelength pump-probe microscopy analysis of melanin composition

    PubMed Central

    Thompson, Andrew; Robles, Francisco E.; Wilson, Jesse W.; Deb, Sanghamitra; Calderbank, Robert; Warren, Warren S.

    2016-01-01

    Pump-probe microscopy is an emerging technique that provides detailed chemical information of absorbers with sub-micrometer spatial resolution. Recent work has shown that the pump-probe signals from melanin in human skin cancers correlate well with clinical concern, but it has been difficult to infer the molecular origins of these differences. Here we develop a mathematical framework to describe the pump-probe dynamics of melanin in human pigmented tissue samples, which treats the ensemble of individual chromophores that make up melanin as Gaussian absorbers with bandwidth related via Frenkel excitons. Thus, observed signals result from an interplay between the spectral bandwidths of the individual underlying chromophores and spectral proximity of the pump and probe wavelengths. The model is tested using a dual-wavelength pump-probe approach and a novel signal processing method based on gnomonic projections. Results show signals can be described by a single linear transition path with different rates of progress for different individual pump-probe wavelength pairs. Moreover, the combined dual-wavelength data shows a nonlinear transition that supports our mathematical framework and the excitonic model to describe the optical properties of melanin. The novel gnomonic projection analysis can also be an attractive generic tool for analyzing mixing paths in biomolecular and analytical chemistry. PMID:27833147

  5. High aspect ratio, remote controlled pumping assembly

    DOEpatents

    Brown, Steve B.; Milanovich, Fred P.

    1995-01-01

    A miniature dual syringe-type pump assembly which has a high aspect ratio and which is remotely controlled, for use such as in a small diameter penetrometer cone or well packer used in water contamination applications. The pump assembly may be used to supply and remove a reagent to a water contamination sensor, for example, and includes a motor, gearhead and motor encoder assembly for turning a drive screw for an actuator which provides pushing on one syringe and pulling on the other syringe for injecting new reagent and withdrawing used reagent from an associated sensor.

  6. High aspect ratio, remote controlled pumping assembly

    DOEpatents

    Brown, S.B.; Milanovich, F.P.

    1995-11-14

    A miniature dual syringe-type pump assembly is described which has a high aspect ratio and which is remotely controlled, for use such as in a small diameter penetrometer cone or well packer used in water contamination applications. The pump assembly may be used to supply and remove a reagent to a water contamination sensor, for example, and includes a motor, gearhead and motor encoder assembly for turning a drive screw for an actuator which provides pushing on one syringe and pulling on the other syringe for injecting new reagent and withdrawing used reagent from an associated sensor. 4 figs.

  7. Electroosmotic pump performance is affected by concentration polarizations of both electrodes and pump

    PubMed Central

    Suss, Matthew E.; Mani, Ali; Zangle, Thomas A.; Santiago, Juan G.

    2010-01-01

    Current methods of optimizing electroosmotic (EO) pump performance include reducing pore diameter and reducing ionic strength of the pumped electrolyte. However, these approaches each increase the fraction of total ionic current carried by diffuse electric double layer (EDL) counterions. When this fraction becomes significant, concentration polarization (CP) effects become important, and traditional EO pump models are no longer valid. We here report on the first simultaneous concentration field measurements, pH visualizations, flow rate, and voltage measurements on such systems. Together, these measurements elucidate key parameters affecting EO pump performance in the CP dominated regime. Concentration field visualizations show propagating CP enrichment and depletion fronts sourced by our pump substrate and traveling at order mm/min velocities through millimeter-scale channels connected serially to our pump. The observed propagation in millimeter-scale channels is not explained by current propagating CP models. Additionally, visualizations show that CP fronts are sourced by and propagate from the electrodes of our system, and then interact with the EO pump-generated CP zones. With pH visualizations, we directly detect that electrolyte properties vary sharply across the anode enrichment front interface. Our observations lead us to hypothesize possible mechanisms for the propagation of both pump- and electrode-sourced CP zones. Lastly, our experiments show the dynamics associated with the interaction of electrode and membrane CP fronts, and we describe the effect of these phenomena on EO pump flow rates and applied voltages under galvanostatic conditions. PMID:21516230

  8. Darrieus wind-turbine and pump performance for low-lift irrigation pumping

    NASA Astrophysics Data System (ADS)

    Hagen, L. J.; Sharif, M.

    1981-10-01

    In the Great Plains about 15 percent of the irrigation water pumped on farms comes from surface water sources; for the United States as a whole, the figure is about 22 percent. Because of forecast fuel shortages, there is a need to develop alternative energy sources such as wind power for surface water pumping. Specific objectives of this investigation were to: design and assemble a prototype wind powered pumping system for low lift irrigation pumping; determine performance of the prototype system; design and test an irrigation system using the wind powered prototype in a design and test an farm application; and determine the size combinations of wind turbines, tailwater pits, and temporary storage reservoirs needed for successful farm application of wind powered tailwater pumping systems in western Kansas. The power source selected was a two bladed, 6 m diameter, 9 m tall Darrieus vertical axis wind turbine with 0.10 solidity and 36.1 M(2) swept area.

  9. Pump Diode Characterization for an Unstable Diode-Pumped Alkali Laser Resonator

    DTIC Science & Technology

    2013-03-01

    2003. Petersen, A., and R. Lane, Second harmonic operation of diode-pumped Rb vapor lasers , Proc. of SPIE, 7005, 2008. Siegman , A. E., Lasers ...University Science Books, Sausalito, CA, 1986. Siegman , A. E., Defining, measuring and optimizing laser beam quality, Proc. of SPIE, 1868, 1993. Steck, D...PUMP DIODE CHARACTERIZATION FOR AN UNSTABLE DIODE-PUMPED ALKALI LASER RESONATOR THESIS Chad T. Taguba, Master Sergeant, USAF AFIT-ENP-13-M-33

  10. DIRECT CURRENT ELECTROMAGNETIC PUMP

    DOEpatents

    Barnes, A.H.

    1957-11-01

    An improved d-c electromagnetic pump is presented in which the poles, and consequently the magetic gap at the poles, are tapered to be wider at the upstream end. In addition, the cross section of the tube carryiQ the liquid metal is tapered so that the velocity of the pumped liquid increases in the downstream direction at a rate such that the counter-induced voltage in the liquid metal remains constant as it traverses the region between the poles. This configuration compensates for the distortion of the magnetic field caused by the induced voltage that would otherwise result in the lowering of the pumping capacity. This improved electromagnetic pump as practical application in the pumping of liquid metal coolants for nuclear reactors where conventional positive displacement pumps have proved unsatisfactory due to the high temperatures and the corrosive properties of the liquid metals involved.

  11. Development of a microfluidic device for simultaneous mixing and pumping

    NASA Astrophysics Data System (ADS)

    Kim, Byoung Jae; Yoon, Sang Youl; Lee, Kyung Heon; Sung, Hyung Jin

    2009-01-01

    We conducted experimental and numerical studies aimed at developing a microfluidic device capable of simultaneous mixing while pumping. The proposed multifunctional device makes use of alternating current electroosmotic flow and adopts an array of planar asymmetric microelectrodes with a diagonal or herringbone shape. The pumping performance was assessed in terms of the fluid velocity at the center of the microchannel, obtained by micro PIV. To assess the mixing, flow visualizations were carried out over the electrodes to verify the lateral flows. The mixing degree was quantified in terms of a mixing efficiency obtained by three-dimensional numerical simulations. The results showed that simultaneous mixing and pumping was achieved in the channels with diagonal or herringbone electrode configurations. A herringbone electrode configuration showed better pumping compared with a reference, as well as enhanced mixing.

  12. A Teaspoon Pump for Pumping Blood with High Hydraulic Efficiency and Low Hemolysis Potential.

    PubMed

    Dame, Don

    1996-05-01

    Virtually all blood pumps contain some kind of rubbing, sliding, closely moving machinery surfaces that are exposed to the blood being pumped. These valves, internal bearings, magnetic bearing position sensors, and shaft seals cause most of the problems with blood pumps. The original teaspoon pump design prevented the rubbing, sliding machinery surfaces from contacting the blood. However, the hydraulic efficiency was low because the blood was able to "slip around" the rotating impeller so that the blood itself never rotated fast enough to develop adequate pressure. An improved teaspoon blood pump has been designed and tested and has shown acceptable hydraulic performance and low hemolysis potential. The new pump uses a nonrotating "swinging" hose as the pump impeller. The fluid enters the pump through the center of the swinging hose; therefore, there can be no fluid slip between the revolving blood and the revolving impeller. The new pump uses an impeller that is comparable to a flexible garden hose. If the free end of the hose were swung around in a circle like half of a jump rope, the fluid inside the hose would rotate and develop pressure even though the hose impeller itself did not "rotate"; therefore, no rotating shaft seal or internal bearings are required. © 1996 International Society for Artificial Organs.

  13. A teaspoon pump for pumping blood with high hydraulic efficiency and low hemolysis potential.

    PubMed

    Dame, D

    1996-06-01

    Virtually all blood pumps contain some kind of rubbing, sliding, closely moving machinery surfaces that are exposed to the blood being pumped. These valves, internal bearings, magnetic bearing position sensors, and shaft seals cause most of the problems with blood pumps. The original teaspoon pump design prevented the rubbing, sliding machinery surfaces from contacting the blood. However, the hydraulic efficiency was low because the blood was able to "slip around" the rotating impeller so that the blood itself never rotated fast enough to develop adequate pressure. An improved teaspoon blood pump has been designed and tested and has shown acceptable hydraulic performance and low hemolysis potential. The new pump uses a nonrotating "swinging" hose as the pump impeller. The fluid enters the pump through the center of the swinging hose; therefore, there can be no fluid slip between the revolving blood and the revolving impeller. The new pump uses an impeller that is comparable to a flexible garden hose. If the free end of the hose were swung around in a circle like half of a jump rope, the fluid inside the hose would rotate and develop pressure even though the hose impeller itself did not "rotate"; therefore, no rotating shaft seal or internal bearings are required.

  14. Electrically pumped edge-emitting photonic bandgap semiconductor laser

    DOEpatents

    Lin, Shawn-Yu; Zubrzycki, Walter J.

    2004-01-06

    A highly efficient, electrically pumped edge-emitting semiconductor laser based on a one- or two-dimensional photonic bandgap (PBG) structure is described. The laser optical cavity is formed using a pair of PBG mirrors operating in the photonic band gap regime. Transverse confinement is achieved by surrounding an active semiconductor layer of high refractive index with lower-index cladding layers. The cladding layers can be electrically insulating in the passive PBG mirror and waveguide regions with a small conducting aperture for efficient channeling of the injection pump current into the active region. The active layer can comprise a quantum well structure. The quantum well structure can be relaxed in the passive regions to provide efficient extraction of laser light from the active region.

  15. Heuristic control of the Utah/MIT dextrous robot hand

    NASA Technical Reports Server (NTRS)

    Bass, Andrew H., Jr.

    1987-01-01

    Basic hand grips and sensor interactions that a dextrous robot hand will need as part of the operation of an EVA Retriever are analyzed. What is to be done with a dextrous robot hand is examined along with how such a complex machine might be controlled. It was assumed throughout that an anthropomorphic robot hand should perform tasks just as a human would; i.e., the most efficient approach to developing control strategies for the hand would be to model actual hand actions and do the same tasks in the same ways. Therefore, basic hand grips that human hands perform, as well as hand grip action were analyzed. It was also important to examine what is termed sensor fusion. This is the integration of various disparate sensor feedback paths. These feedback paths can be spatially and temporally separated, as well as, of different sensor types. Neural networks are seen as a means of integrating these varied sensor inputs and types. Basic heuristics of hand actions and grips were developed. These heuristics offer promise of control dextrous robot hands in a more natural and efficient way.

  16. Solar-pumped electronic-to-vibrational energy transfer lasers

    NASA Technical Reports Server (NTRS)

    Harries, W. L.; Wilson, J. W.

    1981-01-01

    The possibility of using solar-pumped lasers as solar energy converters is examined. The absorbing media considered are halogens or halogen compounds, which are dissociated to yield excited atoms, which then hand over energy to a molecular lasing medium. Estimates of the temperature effects for a Br2-CO2-He system with He as the cooling gas are given. High temperatures can cause the lower energy levels of the CO2 laser transition to be filled. The inverted populations are calculated and lasing should be possible. However, the efficiency is less than 0.001. Examination of other halogen-molecular lasant combinations (where the rate coefficients are known) indicate efficiencies in all cases of less than 0.005.

  17. Diabetes: How and RDN Can Help with Diabetes

    MedlinePlus

    ... that your daily cup (or three!) provides some health benefits. How an RDN Can Help with Diabetes Maintaining ... Keep Your Picnic Safe Food Safety Tips for Outdoor Dining Keep Your Picnic Safe Dads and Breast- ...

  18. Evaluation of Ti-Zr-V (NEG) Thin Films for their pumping speed and pumping Capacity

    NASA Astrophysics Data System (ADS)

    Bansod, Tripti; Sindal, B. K.; Kumar, K. V. A. N. P. S.; Shukla, S. K.

    2012-11-01

    Deposition of NEG thin films onto the interior walls of the vacuum chambers is an advanced technique to convert a vacuum chamber from a gas source to an effective pump. These films offer considerably large pumping speed for reactive gases like CO, H2 etc. A UHV compatible pumping speed measurement system was developed in-house to measure the pumping speed of NEG coated chambers. To inject the fixed quantity of CO and H2 gas in pumping speed measurement set-up a calibrated leak was also developed. Stainless steel chambers were sputter coated with thin film of Ti-Zr-V getter material using varied parameters for different compositions and thickness. Pumping capacity which is a function of sorbed gas quantities was also studied at various activation temperatures. In order to optimize the activation temperature for maximum pumping speed for CO and H2, pumping speeds were measured at room temperature after activation at different temperatures. The experimental system detail, pumping performance of the NEG film at various activation temperatures and RGA analysis are presented.

  19. Liquid Hydrogen Pump

    DTIC Science & Technology

    1964-11-01

    Diagram 183 65 Hub’ess Inducer Impeller and Shroud Prior Prior to Brazing 189 66 Hubless Inducer Impeller Assembly After Brazing and Finish Machining...Cross-Section of Shrouded Hubless Indjcer Pump 195 71 Liquid Hydrogen Pump Test Site, San Tan, Arizona 197 72 Installation of Pump and Overall )est Site...speed of 300,000. It operates at a tip speed of 1260 ft per second. The impeller is a shrouded wheel designed with sufficient strength to carry the

  20. [Influence of proton pump inhibitors on intestinal fermentative profile: a case-control study].

    PubMed

    Senderovky, Melisa; Lasa, Juan; Dima, Guillermo; Peralta, Daniel; Argüello, Mariano; Soifer, Luis

    2014-01-01

    Proton pump inhibitors could have an impact on the results of breath tests performed in patients with irritable bowel syndrome. This impact could be due to the development of small intestine bacterial overgrowth. To compare the prevalence of fermentative profile alterations of irritable bowel syndrome patients exposed and not-exposed to proton pump inhibitor therapy. Subjects with irritable bowel syndrome were enrolled. A validated questionnaire assessing symptom severity as well as proton pump inhibitor treatment was delivered. A lactulose breath test was undertaken by each enrolled subject. Fermentative profile (area under the curve of hydrogen excretion/time) was compared between proton pump inhibitors consumers and non-consumers. Furthermore, small intestine bacterial overgrowth prevalence was compared. Two hundred and twenty five patients were enrolled. No significant differences were found on the fermentative profile between groups [AUC mediana 3,776 (rango 2,124-5,571) vs 4,347 (rango 2,038-5,481), P = 0.3]. Small intestine bacterial overgrowth prevalence was similar as well [33% vs 27.5%]. These differences remained non-significant after adjusting for proton pump inhibitor dose and treatment time. Surprisingly, symptom score was significantly higher in those patients under proton pump inhibitor therapy [28.5 (23-26) vs 23 (15-29), P = 0.01]. Proton pump inhibitors have no significant influence on lactulose breath tests, regardless of the dosage and time of administration.

  1. The Evolution of Ion Pumps.

    ERIC Educational Resources Information Center

    Maloney, Peter C.; Wilson, T. Hastings

    1985-01-01

    Constructs an evolutionary sequence to account for the diversity of ion pumps found today. Explanations include primary ion pumps in bacteria, features and distribution of ATP-driven pumps, preference for cation transport, and proton pump reversal. The integrated evolutionary hypothesis should encourage new experimental approaches. (DH)

  2. Monitoring the ground water level change during the pump test by using the Electric resistivity tomography

    NASA Astrophysics Data System (ADS)

    Hsu, H.; Chang, P. Y.; Yao, H. J.

    2017-12-01

    For hydrodynamics study of the unconfined aquifer in gravel formation, a pumping test was established to estimate the hydraulic conductivity in the midstream of Zhoushui River in Taiwan. The hydraulic parameters and the cone of depression could be estimated by monitoring the groundwater drawdown in an observation well which was in a short distance far from the pumping well. In this study we carried out the electric resistivity image monitoring during the whole pumping test. The electric resistivity data was measured with the surface and downhole electrodes which would produce a clear subsurface image of groundwater level through a larger distance than the distance between pumping and observation wells. The 2D electric image could also describe how a cone of depression truly created at subsurface. The continuous records could also show the change of groundwater level during the whole pumping test which could give a larger scale of the hydraulic parameters.

  3. Which Breast Pump for Which Mother: An Evidenced-Based Approach to Individualizing Breast Pump Technology

    PubMed Central

    Meier, Paula P.; Patel, Aloka L.; Hoban, Rebecca; Engstrom, Janet L.

    2015-01-01

    The majority of new mothers in the United States use breast pumps in the first four months post-birth in order to achieve their personal human milk feeding goals. Although these mothers seek guidance from health care professionals with respect to the type and use of breast pumps, there are few evidence-based guidelines to guide this professional advice. This paper reviews the evidence to facilitate professional individualization of breast pump recommendations using three categories of literature: the infant as the gold standard to which the pump is compared; the degree of maternal breast pump dependency (e.g., the extent to which the breast pump replaces the infant for milk removal and mammary gland stimulation); and the stage of lactation for which the pump replaces the infant. This review can also serve to inform public and private payers with respect to individualizing breast pump type to mother-dyad characteristics. PMID:26914013

  4. Servo Controlled Variable Pressure Modification to Space Shuttle Hydraulic Pump

    NASA Technical Reports Server (NTRS)

    Kouns, H. H.

    1983-01-01

    Engineering drawings show modifications made to the constant pressure control of the model AP27V-7 hydraulic pump to an electrically controlled variable pressure setting compensator. A hanger position indicator was included for continuously monitoring hanger angle. A simplex servo driver was furnished for controlling the pressure setting servovalve. Calibration of the rotary variable displacement transducer is described as well as pump performance and response characteristics.

  5. Non-invasive assessment of thromboembolism in rotary blood pumps: case study

    NASA Astrophysics Data System (ADS)

    Gawlikowski, Maciej; Kustosz, Roman; Głowacki, Maciej; Pydziński, Paweł; Kubacki, Krzysztof; Zakliczyński, Michał; Copik, Izabela; Pacholewicz, Jerzy

    2017-08-01

    Thromboembolic complications are one of the major problems in mechanical heart support of patients suffering from critical heart failure. The goal of the study was to present and discuss methodology of non-invasive assessment of embolization in rotary blood pumps. The study was carried out based on power consumption trend analysis as well as spectral analysis of acoustic signal produced by the pump during its operation. It has been demonstrated that the trend of power rising and presence of 3rd harmonic in acoustic spectrum corresponds to the clinical symptoms of pump embolization.

  6. Stimulated emission in quantum well laser diodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blood, P.

    1989-07-03

    We observe that stimulated emission from inhomogeneously pumped quantum well laser diodes is shifted down in energy compared with the subband transition energy. Measured spontaneous emission spectra show that this stimulated emission is due to band-to-band transitions shifted by renormalization at high injected carrier densities, and we suggest that this same mechanism explains reported observations of stimulated emission from inhomogeneously photopumped structures which previously have been interpreted as evidence for longitudinal optic (LO) phonon participation. We show that LO phonon participation cannot account for the photon energy of stimulated emission from conventional homogeneously pumped quantum well laser diodes.

  7. 12. Sewage Ejector Pumps, view to the southwest. These pumps ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Sewage Ejector Pumps, view to the southwest. These pumps are connected to sewage treatment tanks. - Washington Water Power Clark Fork River Cabinet Gorge Hydroelectric Development, Powerhouse, North Bank of Clark Fork River at Cabinet Gorge, Cabinet, Bonner County, ID

  8. Diagnosis and staging of female genital tract melanocytic lesions using pump-probe microscopy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Robles, Francisco E.; Selim, Maria A.; Warren, Warren S.

    2016-02-01

    Melanoma of the vulva is the second most common type of malignancy afflicting that organ. This disease caries poor prognosis, and shows tendencies to recur locally and develop distant metastases through hematogenous dissemination. Further, there exists significant clinical overlap between early-stage melanomas and melanotic macules, benign lesions that are believed to develop in about 10% of the general female population. In this work we apply a novel nonlinear optical method, pump-probe microscopy, to quantitatively analyze female genitalia tract melanocytic lesions. Pump-probe microscopy provides chemical information of endogenous pigments by probing their electronic excited state dynamics, with subcellular resolution. Using unstained biopsy sections from 31 patients, we find significant differences between melanin type and structure in tissue regions with invasive melanoma, melanoma in-situ and non-malignant melanocytic proliferations (e.g., nevi, melanocytic macules). The molecular images of non-malignant lesion have a well-organized structure, with relatively homogenous pigment chemistry, most often consistent with that of eumelanin with large aggregate size or void of metals, such as iron. On the other hand, pigment type and structure observed in melanomas in-situ and invasive melanomas is typically much more heterogeneous, with larger contributions from pheomelanin, melanins with larger metal content, and/or melanins with smaller aggregate size. Of most significance, clear differences can be observed between melanocytic macules and vulvar melanoma in-situ, which, as discussed above, can be difficult to clinically distinguish. This initial study demonstrates pump-probe microscopy's potential as an adjuvant diagnostic tool by revealing systematic chemical and morphological differences in melanin pigmentation among invasive melanoma, melanoma in-situ and non-malignant melanocytic lesions.

  9. Pantoprazole: a new proton pump inhibitor.

    PubMed

    Jungnickel, P W

    2000-11-01

    This paper reviews the pharmacology, clinical efficacy, and tolerability of pantoprazole in comparison with those of other available proton pump inhibitors (PPIs). Relevant English-language research and review articles were identified by database searches of MEDLINE, International Pharmaceutical Abstracts, and UnCover, and by examining the reference lists of the articles so identified. In selecting data for inclusion, the author gave preference to full-length articles published in peer-reviewed journals. Like other PPIs, pantoprazole exerts its pharmacodynamic actions by binding to the proton pump (H+,K+ -adenosine triphosphatase) in the parietal cells, but, compared with other PPIs, its binding may be more specific for the proton pump. Pantoprazole is well absorbed when administered as an enteric-coated, delayed-release tablet, with an oral bioavailability of approximately 77%. It is hepatically metabolized via cytochrome P2C19 to hydroxypantoprazole, an inactive metabolite that subsequently undergoes sulfate conjugation. The elimination half-life ranges from 0.9 to 1.9 hours and is independent of dose. Pantoprazole has similar efficacy to other PPIs in the healing of gastric and duodenal ulcers, as well as erosive esophagitis, and as part of triple-drug regimens for the eradication of Helicobacter pylori from the gastric mucosa. It is well tolerated, with the most common adverse effects being headache, diarrhea, flatulence, and abdominal pain. In clinical studies, it has been shown to have no interactions with various other agents, including carbamazepine, cisapride, cyclosporine, digoxin, phenytoin, theophylline, and warfarin. Pantoprazole appears to be as effective as other PPIs. Its low potential for drug interactions may give it an advantage in patients taking other drugs.

  10. An economic evaluation comparison of solar water pumping system with engine pumping system for rice cultivation

    NASA Astrophysics Data System (ADS)

    Treephak, Kasem; Thongpron, Jutturit; Somsak, Dhirasak; Saelao, Jeerawan; Patcharaprakiti, Nopporn

    2015-08-01

    In this paper we propose the design and economic evaluation of the water pumping systems for rice cultivation using solar energy, gasoline fuel and compare both systems. The design of the water and gasoline engine pumping system were evaluated. The gasoline fuel cost used in rice cultivation in an area of 1.6 acres. Under same conditions of water pumping system is replaced by the photovoltaic system which is composed of a solar panel, a converter and an electric motor pump which is compose of a direct current (DC) motor or an alternating current (AC) motor with an inverter. In addition, the battery is installed to increase the efficiency and productivity of rice cultivation. In order to verify, the simulation and economic evaluation of the storage energy battery system with batteries and without batteries are carried out. Finally the cost of four solar pumping systems was evaluated and compared with that of the gasoline pump. The results showed that the solar pumping system can be used to replace the gasoline water pumping system and DC solar pump has a payback less than 10 years. The systems that can payback the fastest is the DC solar pumping system without batteries storage system. The system the can payback the slowest is AC solar pumping system with batteries storage system. However, VAC motor pump of 220 V can be more easily maintained than the motor pump of 24 VDC and batteries back up system can supply a more stable power to the pump system.

  11. High-power diode laser bars as pump sources for fiber lasers and amplifiers (Invited Paper)

    NASA Astrophysics Data System (ADS)

    Bonati, G.; Hennig, P.; Wolff, D.; Voelckel, H.; Gabler, T.; Krause, U.; T'nnermann, A.; Reich, M.; Limpert, J.; Werner, E.; Liem, A.

    2005-04-01

    Fiber lasers are pumped by fibercoupled, multimode single chip devices at 915nm. That"s what everybody assumes when asked for the type of fiber laser pumps and it was like this for many years. Coming up as an amplifier for telecom applications, the amount of pump power needed was in the range of several watts. Highest pump powers for a limited market entered the ten watts range. This is a range of power that can be covered by highly reliable multimode chips, that have to survive up to 25 years, e.g. in submarine applications. With fiber lasers entering the power range and the application fields of rod and thin disc lasers, the amount of pump power needed raised into the area of several hundred watts. In this area of pump power, usually bar based pumps are used. This is due to the much higher cost pressure of the industrial customers compared to telecom customers. We expect more then 70% of all industrial systems to be pumped by diode laser bars. Predictions that bar based pumps survive for just a thousand hours in cw-operation and fractions of this if pulsed are wrong. Bar based pumps have to perform on full power for 10.000h on Micro channel heat sinks and 20.000h on passive heatsinks in industrial applications, and they do. We will show a variety of data, "real" long time tests and statistics from the JENOPTIK Laserdiode as well as data of thousands of bars in the field, showing that bar based pumps are not just well suitable for industrial applications on high power levels, but even showing benefits compared to chip based pumps. And it"s reasonable, that the same objectives of cost effectiveness, power and lifetime apply as well to thin disc, rod and slab lasers as to fiber lasers. Due to the pumping of fiber lasers, examples will be shown, how to utilize bars for high brightness fiber coupling. In this area, the automation is on its way to reduce the costs on the fibercoupling, similar to what had been done in the single chip business. All these efforts are

  12. Changes in arm-hand function and arm-hand skill performance in patients after stroke during and after rehabilitation.

    PubMed

    Franck, Johan Anton; Smeets, Rob Johannes Elise Marie; Seelen, Henk Alexander Maria

    2017-01-01

    Arm-hand rehabilitation programs applied in stroke rehabilitation frequently target specific populations and thus are less applicable in heterogeneous patient populations. Besides, changes in arm-hand function (AHF) and arm-hand skill performance (AHSP) during and after a specific and well-described rehabilitation treatment are often not well evaluated. This single-armed prospective cohort study featured three subgroups of stroke patients with either a severely, moderately or mildly impaired AHF. Rehabilitation treatment consisted of a Concise_Arm_and_hand_ Rehabilitation_Approach_in_Stroke (CARAS). Measurements at function and activity level were performed at admission, clinical discharge, 3, 6, 9 and 12 months after clinical discharge. Eighty-nine stroke patients (M/F:63/23; mean age:57.6yr (+/-10.6); post-stroke time:29.8 days (+/-20.1)) participated. All patients improved on AHF and arm-hand capacity during and after rehabilitation, except on grip strength in the severely affected subgroup. Largest gains occurred in patients with a moderately affected AHF. As to self-perceived AHSP, on average, all subgroups improved over time. A small percentage of patients declined regarding self-perceived AHSP post-rehabilitation. A majority of stroke patients across the whole arm-hand impairment severity spectrum significantly improved on AHF, arm-hand capacity and self-perceived AHSP. These were maintained up to one year post-rehabilitation. Results may serve as a control condition in future studies.

  13. Thermal Lens Measurement in Diode-Pumped Nd:YAG Zig-Zag Slab

    NASA Technical Reports Server (NTRS)

    Smoak, M. C.; Kay, R. B.; Coyle, D. B.; Hopf, D.

    1998-01-01

    A major advantage that solid state zig-zag slab lasers have over conventional rod-based designs is that a much weaker thermal lens is produced in the slab when side-pumped with Quasi-CW laser diode arrays, particularly if the pump radiation is kept well away from the Brewster-cut ends. This paper reports on a rather strong thermal lens produced when diode pump radiation is collimated into a narrow portion of the zig-zag slab. The collimation of multi-bar pump packages to increase brightness and improve overlap is a direct consequence of designs which seek to maximize performance and efficiency. Our slab design employed a 8.1 cm x 2.5 mm x 5 mm slab with opposing Brewster end faces. It was pumped through the 2.5 mm direction by seven laser diode array packages, each housing four 6OW diode bars, 1 cm in width. The pump face, anti-reflection (AR) coated at 809 nm, was 6.8 cm in width and the 8.1 cm opposing side, high-reflection (HR) coated at 809 nm, reflected the unabsorbed pump beam for a second pass through the slab.

  14. Pumping capacity and reliability of cryogenic micro-pump for micro-satellite applications

    NASA Astrophysics Data System (ADS)

    Zhang, Xin; Zhao, Yi; Li, Biao; Ludlow, Daryl

    2004-10-01

    In micro-satellites, delicate instruments are compacted into a limited space. This raises concerns of active cooling and remote cooling. Silicon based micro-pump arrays are employed thanks to manufacturing simplicity, a small cryogen charge, etc, and keep the instruments within a narrow cryogenic temperature range. The pumping capacity and reliability of the micro-pump are critical in terms of heat balance calculation and lifetime evaluation. The pumping capacity is associated with the diaphragm deflection while the reliability is associated with stress and fatigue. Both of them heavily depend on the silicon diaphragm, one of the key components. This paper examines the pumping capacity and reliability of the micro-pump under cryogenic temperature for micro-satellite applications. In this work, differential pressure was used for the actuation of a single-crystal silicon diaphragm. Diaphragm deflection and stress distribution were achieved using interferometry and micro-Raman spectroscopy, respectively. As a result, smaller pumping capacity was derived under cryogenic temperature, compared to that under room temperature, indicating a stiffer material. From stress mapping, the edge centers were believed to be the most vulnerable to fracture, which was further validated by analyzing the fracture diaphragm. Moreover, a fatigue testing was conducted for 1.8 million cycles with no damage found, verifying silicon as a viable material for long time operation in a cryogenic environment.

  15. Recursive approach of EEG-segment-based principal component analysis substantially reduces cryogenic pump artifacts in simultaneous EEG-fMRI data.

    PubMed

    Kim, Hyun-Chul; Yoo, Seung-Schik; Lee, Jong-Hwan

    2015-01-01

    Electroencephalography (EEG) data simultaneously acquired with functional magnetic resonance imaging (fMRI) data are preprocessed to remove gradient artifacts (GAs) and ballistocardiographic artifacts (BCAs). Nonetheless, these data, especially in the gamma frequency range, can be contaminated by residual artifacts produced by mechanical vibrations in the MRI system, in particular the cryogenic pump that compresses and transports the helium that chills the magnet (the helium-pump). However, few options are available for the removal of helium-pump artifacts. In this study, we propose a recursive approach of EEG-segment-based principal component analysis (rsPCA) that enables the removal of these helium-pump artifacts. Using the rsPCA method, feature vectors representing helium-pump artifacts were successfully extracted as eigenvectors, and the reconstructed signals of the feature vectors were subsequently removed. A test using simultaneous EEG-fMRI data acquired from left-hand (LH) and right-hand (RH) clenching tasks performed by volunteers found that the proposed rsPCA method substantially reduced helium-pump artifacts in the EEG data and significantly enhanced task-related gamma band activity levels (p=0.0038 and 0.0363 for LH and RH tasks, respectively) in EEG data that have had GAs and BCAs removed. The spatial patterns of the fMRI data were estimated using a hemodynamic response function (HRF) modeled from the estimated gamma band activity in a general linear model (GLM) framework. Active voxel clusters were identified in the post-/pre-central gyri of motor area, only from the rsPCA method (uncorrected p<0.001 for both LH/RH tasks). In addition, the superior temporal pole areas were consistently observed (uncorrected p<0.001 for the LH task and uncorrected p<0.05 for the RH task) in the spatial patterns of the HRF model for gamma band activity when the task paradigm and movement were also included in the GLM. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Amplification of a seed pumped by a chirped laser in the strong coupling Brillouin regime

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schluck, F.; Lehmann, G.; Spatschek, K. H.

    Seed amplification via Brillouin backscattering of a long pump laser-pulse is considered. The interaction takes place in the so called strong coupling regime. Pump chirping is applied to mitigate spontaneous Raman backscattering of the pump before interacting with the seed. The strong coupling regime facilitates stronger exponential growth and narrower seeds compared to the so called weak coupling regime, although in the latter the scaling with pump amplitude is stronger. Strong coupling is achieved when the pump laser amplitude exceeds a certain threshold. It is shown how the chirp influences both the linear as well as the nonlinear amplification process.more » First, linear amplification as well as the seed profiles are determined in dependence of the chirping rate. In contrast to the weak coupling situation, the evolution is not symmetric with respect to the sign of the chirping rate. In the nonlinear stage of the amplification, we find an intrinsic chirp of the seed pulse even for an un-chirped pump. We show that chirping the pump may have a strong influence on the shape of the seed in the nonlinear amplification phase. Also, the influence of pump chirp on the efficiency of Brillouin seed amplification is discussed.« less

  17. Tank 26 Evaporator Feed Pump Transfer Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tamburello, David; Dimenna, Richard; Lee, Si

    2009-02-11

    The transfer of liquid salt solution from Tank 26 to an evaporator is to be accomplished by activating the evaporator feed pump, located approximately 72 inches above the sludge layer, while simultaneously turning on the downcomer. Previously, activation of the evaporator feed pump was an isolated event without any other components running at the same time. An analysis of the dissolved solution transfer has been performed using computational fluid dynamics methods to determine the amount of entrained sludge solids pumped out of the tank to the evaporator with the downcomer turned on. The analysis results showed that, for the maximummore » and minimum supernate levels in Tank 26 (252.5 and 72 inches above the sludge layer, respectively), the evaporator feed pump will entrain between 0.03 and 0.1 wt% sludge undissolved solids weight fraction into the eductor, respectively, and therefore are an order of magnitude less than the 1.0 wt% undissolved solids loading criteria to feed the evaporator. Lower tank liquid levels, with respect to the sludge layer, result in higher amounts of sludge entrainment due to the increased velocity of the plunging jets from the downcomer and evaporator feed pump bypass as well as decreased dissipation depth. Revision 1 clarifies the analysis presented in Revision 0 and corrects a mathematical error in the calculations for Table 4.1 in Revision 0. However, the conclusions and recommendations of the analysis do not change for Revision 1.« less

  18. Field, laboratory, and modeling investigation of the skin effect at wells with slotted casing, Boise Hydrogeophysical Research Site

    NASA Astrophysics Data System (ADS)

    Barrash, Warren; Clemo, Tom; Fox, Jessica J.; Johnson, Timothy C.

    2006-07-01

    Understanding and quantification of wellbore skin improves our ability to accurately measure or estimate hydrologic parameters with tests at wells such as pumping tests, flowmeter tests, and slug tests. This paper presents observations and results from a series of field, laboratory, and modeling tests which, together, explain the source of wellbore skin at wells at a research wellfield and which support estimation of skin thickness ( ds) and skin hydraulic conductivity ( Ks). Positive wellbore skin effects were recognized at wells in the shallow, unconfined, coarse-grained fluvial aquifer at the Boise Hydrogeophysical Research Site (BHRS). Well development efforts at the BHRS removed residual drilling fines but only marginally reduced the skin effect. Likely causes for the remaining wellbore skin effect were examined; partial clogging of screen slots with sand is consistent with field observations and can account for the magnitude of wellbore skin effect observed. We then use the WTAQ code ( Barlow and Moench, 1999) with a redefinition of the term for delayed observation well response to include skin effects at observation wells (in addition to pumping wells) in order to analyze aquifer tests at the BHRS for average Ks values at individual wells. Systematic differences in Ks values are recognized in results at pumping ( Ks_Q) and observation ( Ks_obs) wells: larger values are seen at observation wells (average Ks_obs=0.0023 cm/s) than pumping wells. Two possible causes are recognized for the occurrence of higher Ks values at observation wells than pumping wells: (1) flow diversion between aquifer layers on approach to a pumping well with positive skin; and (2) larger portion of flow passing through lower-K zones in the heterogeneous aquifer near the pumping well than the observation wells due to strongly radially convergent flow near the pumping well. For the well-aquifer system at the BHRS, modeling analyses of drawdown vs time at observation wells provide better

  19. Temporal Behavior of the Pump Pulses, Residual Pump Pulses, and THz Pulses for D2O Gas Pumped by a TEA CO2 Laser

    NASA Astrophysics Data System (ADS)

    Geng, Lijie; Zhang, Zhifeng; Zhai, Yusheng; Su, Yuling; Zhou, Fanghua; Qu, Yanchen; Zhao, Weijiang

    2016-08-01

    Temporal behavior of the pump pulses, residual pump pulses, and THz pulses for optically pumped D2O gas molecules was investigated by using a tunable TEA CO2 laser as the pumping source. The pulse profiles of pump laser pulses, residual pump pulses, and the THz output pulses were measured, simultaneously, at several different gas pressures. For THz pulse, the pulse delay between the THz pulse and the pump pulse was observed and the delay time was observed to increase from 40 to 70 ns with an increase in gas pressure from 500 to 1700 Pa. Both THz pulse broadening and compression were observed, and the pulse broadening effect transformed to the compression effect with increasing the gas pressure. For the residual pump pulse, the full width at half maximum (FWHM) of the main pulse decreased with increasing gas pressure, and the main pulse disappeared at high gas pressures. The secondary pulses were observed at high gas pressure, and the time intervals of about 518 and 435 ns were observed between the THz output pulse and the secondary residual pump pulse at the pressure of 1400 Pa and 1700 Pa, from which the vibrational relaxation time constants of about 5.45 and 5.55 μs Torr were obtained.

  20. A mini axial and a permanent maglev radial heart pump.

    PubMed

    Qian, Kun-Xi; Ru, Wei-Min; Wang, Hao; Jing, Teng

    2007-05-31

    The implantability and durability have been for decades the focus of artificial heart R&D. A mini axial and a maglev radial pump have been developed to meet with such requirements.The mini axial pump weighing 27g (incl.5g rotor) has an outer diameter of 21mm and a length of 10mm in its largest point, but can produce a maximal blood flow of 6l/min with 50mmHg pressure increase. Therefore, it is suitable for the patients of 40-60kg body weight. For other patients of 60-80kg or 80-100kg body weight, the mini axial pumps of 23mm and 25mm outer diameter had been developed before, these devices were acknowledged to be the world smallest LVADs by Guinness World Record Center in 2004.The permanent maglev radial pump weighing 150g is a shaft-less centrifugal pump with permanent magnetic bearings developed by the author. It needs no second coil for suspension of the rotor except the motor coil, different from all other maglev pumps developed in USA, Japan, European, etc. Thus no detecting and controlling systems as well as no additional power supply for maglev are necessary. The pump can produce a blood flow up to as large as 10l/min against 100mmHg pressure.An implantable and durable blood pump will be a viable alternative to natural donor heart for transplantation.

  1. Direct solar pumping of semiconductor lasers: A feasibility study

    NASA Technical Reports Server (NTRS)

    Anderson, Neal G.

    1991-01-01

    The primary goals of the feasibility study are the following: (1) to provide a preliminary assessment of the feasibility of pumping semiconductor lasers in space directly focused sunlight; and (2) to identify semiconductor laser structures expected to operate at the lowest possible focusing intensities. It should be emphasized that the structures under consideration would provide direct optical-to-optical conversion of sunlight into laser light in a single crystal, in contrast to a configuration consisting of a solar cell or battery electrically pumping a current injection laser. With external modulation, such lasers may prove to be efficient sources for intersatellite communications. We proposed to develop a theoretical model of semiconductor quantum-well lasers photopumped by a broadband source, test it against existing experimental data where possible, and apply it to estimating solar pumping requirements and identifying optimum structures for operation for operation at low pump intensities. This report outlines our progress toward these goals. Discussion of several technical details are left to the attached summary abstract.

  2. 33 CFR 157.126 - Pumps.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Washing (COW) System on Tank Vessels Design, Equipment, and Installation § 157.126 Pumps. (a) Crude oil must be supplied to the COW machines by COW system pumps or cargo pumps. (b) The pumps under paragraph...) A sufficient pressure and flow is supplied to allow the simultaneous operation of those COW machines...

  3. Physiological characterisation of the efflux pump system of antibiotic-susceptible and multidrug-resistant Enterobacter aerogenes.

    PubMed

    Martins, A; Spengler, G; Martins, M; Rodrigues, L; Viveiros, M; Davin-Regli, A; Chevalier, J; Couto, I; Pagès, J M; Amaral, L

    2010-10-01

    Enterobacter aerogenes predominates amongst Enterobacteriaceae species that are increasingly reported as producers of extended-spectrum beta-lactamases. Although this mechanism of resistance to beta-lactams is important, other mechanisms bestowing a multidrug-resistant (MDR) phenotype in this species are now well documented. Amongst these mechanisms is the overexpression of efflux pumps that extrude structurally unrelated antibiotics prior to their reaching their targets. Interestingly, although knowledge of the genetic background behind efflux pumps is rapidly advancing, few studies assess the physiological nature of the overall efflux pump system of this, or for that matter any other, bacterium. The study reported here evaluates physiologically the efflux pump system of an E. aerogenes ATCC reference as well as two strains whose MDR phenotypes are mediated by overexpressed efflux pumps. The activities of the efflux pumps in these strains are modulated by pH and glucose, although the effects of the latter are essentially restricted to pH 8, suggesting the presence of two general efflux pump systems, i.e. proton-motive force-dependent and ABC transporter types, respectively. Copyright 2010 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  4. Specific Yields Estimated from Gravity Change during Pumping Test

    NASA Astrophysics Data System (ADS)

    Chen, K. H.; Hwang, C.; Chang, L. C.

    2017-12-01

    Specific yield (Sy) is the most important parameter to describe available groundwater capacity in an unconfined aquifer. When estimating Sy by a field pumping test, aquifer heterogeneity and well performers will cause a large uncertainty. In this study, we use a gravity-based method to estimate Sy. At the time of pumping test, amounts of mass (groundwater) are forced to be taken out. If drawdown corn is big and close enough to high precision gravimeter, the gravity change can be detected. The gravity-based method use gravity observations that are independent from traditional flow computation. Only the drawdown corn should be modeled with observed head and hydrogeology data. The gravity method can be used in most groundwater field tests, such as locally pumping/injection tests initiated by active man-made or annual variations due to natural sources. We apply our gravity method at few sites in Taiwan situated over different unconfined aquifer. Here pumping tests for Sy determinations were also carried out. We will discuss why the gravity method produces different results from traditional pumping test, field designs and limitations of the gravity method.

  5. Fabrication of Out-of-Plane Electrodes for ACEO Pumps

    NASA Astrophysics Data System (ADS)

    Senousy, Yehya; Harnett, Cindy

    2012-02-01

    This abstract reports the fabrication process of a novel AC Electrosmosis (ACEO) pump with out of plane asymmetric interdigitated electrodes. A self-folding technique is used to fabricate the electrodes, that depends on the strain mismatch between the tensile stressed film (metal layer) and the compressive stress film (oxidized silicon layer). The electrodes roll up with a well-defined radius of curvature in the range of 100-200 microns. Two different electrical signals are connected to alternating electrodes using an insulating silicon nitride barrier that allows circuits to cross over each other without shorting. Electroosmotic micropumps are essential for low-cost, power-efficient microfluidic lab-on-chip devices used in diverse application such as analytical probes, drug delivery systems and surgical tools. ACEO pumps have been developed to address the drawbacks of the DCEO pumps such as the faradic reaction and gas bubbles. The original ACEO microfluidic pump was created with planar arrays of asymmetric interdigitated electrodes at the bottom of the channel. This rolled-up tube design improves on the planar design by including the channel walls and ceiling in the active pumping surface area of the device.

  6. Variable-speed controller provides flexibility to electrical submersible pumps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butlin, D.

    1986-06-09

    The performance of an electric submersible pump (ESP) is dramatically modified by a variable speed controller (VSC). Variable frequency power directly controls pump speed and thus the hydraulic performance of the pump. Even though the ESP is the primary form of artificial lift for high volume, deep oil wells (particularly where gas is unavailable), the biggest disadvantage has been the pump's inflexibility when run at a constant speed, i.e., the unit is limited to a fixed head output at each rate. The VSC has rapidly gained acceptance as a valuable ESP accessory to alleviate this restriction. By allowing the pumpmore » speed to be varied, the rate and head, or both, can be adjusted with no modification of the downhole unit. There are now over 700 VSCs running with ESPs on every continent of the world. Pumping flexibility was the main purpose of applying the VSC to the ESP, but several other benefits have become apparent. Of particular interest are those that can extend downhole equipment life, e.g., soft start, automatically controlled speed, line-transient suppression, and elimination of surface chokes.« less

  7. Performance analysis of solar-assisted chemical heat-pump dryer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fadhel, M.I.; Faculty of Engineering and Technology, Multimedia University, Jalan Ayer Keroh Lama, 75450, Melaka; Sopian, K.

    2010-11-15

    A solar-assisted chemical heat-pump dryer has been designed, fabricated and tested. The performance of the system has been studied under the meteorological conditions of Malaysia. The system consists of four main components: solar collector (evacuated tubes type), storage tank, solid-gas chemical heat pump unit and dryer chamber. A solid-gas chemical heat pump unit consists of reactor, condenser and evaporator. The reaction used in this study (CaCl2-NH{sub 3}). A simulation has been developed, and the predicted results are compared with those obtained from experiments. The maximum efficiency for evacuated tubes solar collector of 80% has been predicted against the maximum experimentmore » of 74%. The maximum values of solar fraction from the simulation and experiment are 0.795 and 0.713, respectively, whereas the coefficient of performance of chemical heat pump (COP{sup h}) maximum values 2.2 and 2 are obtained from simulation and experiments, respectively. The results show that any reduction of energy at condenser as a result of the decrease in solar radiation will decrease the coefficient of performance of chemical heat pump as well as decrease the efficiency of drying. (author)« less

  8. Air Pump-Assisted Graft Centration, Graft Edge Unfolding, and Graft Uncreasing in Young Donor Graft Pre-Descemet Endothelial Keratoplasty.

    PubMed

    Jacob, Soosan; Narasimhan, Smita; Agarwal, Amar; Agarwal, Athiya; A I, Saijimol

    2017-08-01

    To assess an air pump-assisted technique for graft centration, graft edge unfolding, and graft uncreasing while performing pre-Descemet endothelial keratoplasty (PDEK) using young donor grafts. Continuous pressurized air infusion was used for graft centration, graft edge unfolding, and graft unwrinkling. Ten eyes of 10 patients underwent PDEK with donors aged below 40 years. In all eyes, the donor scrolled into tight scrolls. In all cases, the air pump-assisted technique was effective in positioning and centering the graft accurately and in straightening infolded graft edges and smoothing out graft creases and wrinkles. Endothelial cell loss was 38.6%. Postoperative best-corrected visual acuity at 6 months was 0.66 ± 0.25 in decimal equivalent. Continuous pressurized air infusion acted as a third hand providing a continuous pressure head that supported the graft and prevented graft dislocation as well as anterior chamber collapse during intraocular maneuvering. Adequate maneuvering space was available in all cases, and bleeding, if any, was tamponaded successfully in all cases. Although very young donor grafts may be used for PDEK, they are difficult to center and unroll completely before floating against host stroma. An air pump-assisted technique using continuous pressurized air infusion allows successful final graft positioning even with very young donor corneas. It thus makes surgery easier as several key steps are made easier to handle. It additionally helps in tamponading hemorrhage during peripheral iridectomy, increasing surgical space, preventing fluctuations in the anterior chamber depth, and promoting graft adherence.

  9. Rotary magnetic heat pump

    DOEpatents

    Kirol, Lance D.

    1988-01-01

    A rotary magnetic heat pump constructed without flow seals or segmented rotor accomplishes recuperation and regeneration by using split flow paths. Heat exchange fluid pumped through heat exchangers and returned to the heat pump splits into two flow components: one flowing counter to the rotor rotation and one flowing with the rotation.

  10. A Network Pump

    DTIC Science & Technology

    1996-05-01

    introduced as shown in Fig. 3. Pump ~ y { ~ ~ ~ = ~ messages ACK buffer Fig. 3. The Basic Pump The basic Pump [6] places a buffer (size n ) between...exponential distribution with mean x. Define Q = fY(MAll - T,) + k . ( N - Fair size) where N is the number of messages in buffer, at the time the...message is placed in buffer,,, and k . ( N - Fair size) is a feedback term. Both k and Fair size can be chosen by a sys- tem designer. Note that the moving

  11. 49 CFR 195.262 - Pumping equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Pumping equipment. 195.262 Section 195.262... PIPELINE Construction § 195.262 Pumping equipment. (a) Adequate ventilation must be provided in pump... provided in each pump station: (1) Safety devices that prevent overpressuring of pumping equipment...

  12. Bearing for liquid metal pump

    DOEpatents

    Dickinson, Robert J.; Wasko, John; Pennell, William E.

    1984-01-01

    A liquid metal pump bearing support comprises a series of tangentially oriented spokes that connect the bearing cylinder to the pump internals structure. The spokes may be arranged in a plurality of planes extending from the bearing cylinder to the pump internals with the spokes in one plane being arranged alternately with those in the next plane. The bearing support structure provides the pump with sufficient lateral support for the bearing structure together with the capability of accommodating differential thermal expansion without adversely affecting pump performance.

  13. WATER PUMP HOUSE, TRA619. VIEW OF PUMP HOUSE UNDER CONSTRUCTION. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    WATER PUMP HOUSE, TRA-619. VIEW OF PUMP HOUSE UNDER CONSTRUCTION. CAMERA IS ON WATER TOWER AND FACES NORTHWEST. TWO RESERVOIR TANKS ALREADY ARE COMPLETED. NOTE EXCAVATIONS FOR PIPE LINES EXITING FROM BELOW GROUND ON SOUTH SIDE OF PUMP HOUSE. BUILDING AT LOWER RIGHT IS ELECTRICAL CONTROL BUILDING, TRA-623. SWITCHYARD IS IN LOWER RIGHT CORNER OF VIEW. INL NEGATIVE NO. 2753. Unknown Photographer, ca. 6/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  14. Low-cost water-lifting from groundwater sources: a comparison of the EMAS Pump with the Rope Pump

    NASA Astrophysics Data System (ADS)

    MacCarthy, Michael F.; Carpenter, Jacob D.; Mihelcic, James R.

    2017-08-01

    In sub-Saharan Africa, low-cost groundwater supply systems offer great opportunities for the current unserved population of >300 million to access drinking water. A comparative study was performed in Uganda of the EMAS Pump (designed by Escuela Móvil Aguas y Saneamiento Básico) with the trade-named Rope Pump, two low-cost manual water-lifting devices appropriate to pumping from shallow groundwater sources. Pumping rates, energy expended, material costs, and construction requirements were analyzed. Focus was on low-cost application for use in shallow groundwater systems at the household level in developing countries, particularly in sub-Saharan Africa. The study site was northern Uganda, with testing performed at several drilled boreholes. Two variants of each pump were tested by a male and female user, pumping from multiple static water-level depths ranging from 5 to 28 m. Results demonstrated the most common version of the EMAS Pump to perform similarly to the comparable version of the Rope Pump in terms of average pumping rate at depth range 5 to 18 m (93-111%), but less so at deeper depths (63-85%). Normalized pumping rates (considering energy expended) accentuated differences between these versions of the EMAS Pump and Rope Pump (47-97%). Cost of materials to construct the EMAS Pump were 21-60% those of the Rope Pump, and EMAS Pump construction requirements were also less. Based on the assessed factors, it is concluded that the EMAS Pump has potential for success in "self-supply" groundwater systems in sub-Saharan Africa and is particularly appropriate to link with low-cost shallow groundwater sources.

  15. 27. Pump Room interiorDrainage pump motor control center with main ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. Pump Room interior-Drainage pump motor control center with main valve control panel at right. - Hunters Point Naval Shipyard, Drydock No. 4, East terminus of Palou Avenue, San Francisco, San Francisco County, CA

  16. Rotary magnetic heat pump

    DOEpatents

    Kirol, L.D.

    1987-02-11

    A rotary magnetic heat pump constructed without flow seals or segmented rotor accomplishes recuperation and regeneration by using split flow paths. Heat exchange fluid pumped through heat exchangers and returned to the heat pump splits into two flow components: one flowing counter to the rotor rotation and one flowing with the rotation. 5 figs.

  17. 123. UMBILICAL MAST PUMP ROOM (209), LSB (BLDG. 751). PUMP ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    123. UMBILICAL MAST PUMP ROOM (209), LSB (BLDG. 751). PUMP ON LEFT; HYDRAULIC CONTROL PANEL FOR UMBILICAL MAST AND TRENCH DOORS IN CENTER OF ROOM, FACING WEST. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  18. Insulin pump treatment in children and adolescents with type 1 diabetes.

    PubMed

    Hofer, S; Meraner, D; Koehle, J

    2012-08-01

    Within children and adolescents with type 1 diabetes insulin pump treatment is of increasing interest. Frequency of insulin pump therapy shows a rapid and steep increase in toddlers and young children. Insulin pumps allow a close to physiologic insulin delivery due to basal rates programmed over 24 hours with circadian rhythms taken into account. Furthermore, another advantage of technical devices as insulin pumps is the application of extremely small amounts of insulin, as needed in very young children, with the possibility of titration of infusion rates down to 0.01E/h. Dawn Phenomenon and hypoglycemic events are main indications for insulin pump treatment in children and adolescents. A significant reduction of severe hypoglycemia, especially nocturnal hypoglycemia was shown, whereas a reduction of HbA1c and an improvement of metabolic control has been reported in short term and in some but not all long term studies. Ketoacidosis rate did not increase in insulin pump therapy. Complications due to continuous subcutaneous insulin infusion, like local infections and dermatological changes are frequent but were not associated with glycemic control and did not lead to discontinuation of insulin pump treatment. Pump discontinuation rate in general is low, varying from 1% in very young children up to 6% in pubertal adolescent girls. Insulin pump treatment was shown to be safe and efficient and the simplicity of handling the devices as well as an improvement of quality of life may explain the rapid increase of pump treatment in young children and adolescents with type 1 diabetes.

  19. Satellite Propellant Pump Research

    NASA Technical Reports Server (NTRS)

    Schneider, Steven J.; Veres, Joseph P.; Hah, Chunill; Nerone, Anthony L.; Cunningham, Cameron C.; Kraft, Thomas G.; Tavernelli, Paul F.; Fraser, Bryan

    2005-01-01

    NASA Glenn initiated a satellite propellant pump technology demonstration program. The goal was to demonstrate the technologies for a 60 percent efficient pump at 1 gpm flow rate and 500 psia pressure rise. The pump design and analysis used the in-house developed computer codes named PUMPA and HPUMP3D. The requirements lead to a 4-stage impeller type pump design with a tip diameter of 0.54 inches and a rotational speed of 57,000 rpm. Analyses indicated that flow cavitation was not a problem in the design. Since the flow was incompressible, the stages were identical. Only the 2-stage pump was designed, fabricated, assembled, and tested for demonstration. Water was selected as the surrogate fluid for hydrazine in this program. Complete mechanical design including stress and dynamic analyses were conducted. The pump was driven by an electric motor directly coupled to the impellers. Runs up to 57,000 rpm were conducted, where a pressure rise of 200 psia at a flow rate of 0.8 gpm was measured to validate the design effort.

  20. 49 CFR 195.262 - Pumping equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PIPELINE Construction § 195.262 Pumping equipment. (a) Adequate ventilation must be provided in pump... provided in each pump station: (1) Safety devices that prevent overpressuring of pumping equipment..., pumping equipment must be installed on property that is under the control of the operator and at least 15...

  1. 49 CFR 195.262 - Pumping equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PIPELINE Construction § 195.262 Pumping equipment. (a) Adequate ventilation must be provided in pump... provided in each pump station: (1) Safety devices that prevent overpressuring of pumping equipment..., pumping equipment must be installed on property that is under the control of the operator and at least 15...

  2. 49 CFR 195.262 - Pumping equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PIPELINE Construction § 195.262 Pumping equipment. (a) Adequate ventilation must be provided in pump... provided in each pump station: (1) Safety devices that prevent overpressuring of pumping equipment..., pumping equipment must be installed on property that is under the control of the operator and at least 15...

  3. 49 CFR 195.262 - Pumping equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PIPELINE Construction § 195.262 Pumping equipment. (a) Adequate ventilation must be provided in pump... provided in each pump station: (1) Safety devices that prevent overpressuring of pumping equipment..., pumping equipment must be installed on property that is under the control of the operator and at least 15...

  4. Hydraulically-operated pump jack with chain drive

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ratell Jr., R. E.

    1985-02-05

    My invention relates to pumping apparatus, particularly to a hydraulically-operated pump jack for oil, brine water and the like. The apparatus is fabricated from steel plate to make a strong, but light-weight tower which may be easily transported from one site to another by a small boom truck or gin pole truck. In contrast to pump jacks of the walking beam type which are massive in size, my improved pump jack is compact and is seated on and secured directly to the head of an oil well casing. A vertically-arranged hydraulic cylinder has its piston rod connected to a crossmore » head on which a pair of sprockets are journalled. Chains pass around respective sprockets, one reach of each chain extending upwardly and is anchored to a stationary part of the tower. The other reach of each chain extends upwardly and over and around an upper sprocket journalled on a shaft carried by the upper end of the tower, each chain then extending downwardly to a yoke to which the polish rod is connected. This arrangement will result in a 2 to 1 ratio between the movement of the polish rod and the stroke of the hydraulic cylinder.« less

  5. Engine lubrication circuit including two pumps

    DOEpatents

    Lane, William H.

    2006-10-03

    A lubrication pump coupled to the engine is sized such that the it can supply the engine with a predetermined flow volume as soon as the engine reaches a peak torque engine speed. In engines that operate predominately at speeds above the peak torque engine speed, the lubrication pump is often producing lubrication fluid in excess of the predetermined flow volume that is bypassed back to a lubrication fluid source. This arguably results in wasted power. In order to more efficiently lubricate an engine, a lubrication circuit includes a lubrication pump and a variable delivery pump. The lubrication pump is operably coupled to the engine, and the variable delivery pump is in communication with a pump output controller that is operable to vary a lubrication fluid output from the variable delivery pump as a function of at least one of engine speed and lubrication flow volume or system pressure. Thus, the lubrication pump can be sized to produce the predetermined flow volume at a speed range at which the engine predominately operates while the variable delivery pump can supplement lubrication fluid delivery from the lubrication pump at engine speeds below the predominant engine speed range.

  6. Bubble pump: scalable strategy for in-plane liquid routing.

    PubMed

    Oskooei, Ali; Günther, Axel

    2015-07-07

    We present an on-chip liquid routing technique intended for application in well-based microfluidic systems that require long-term active pumping at low to medium flowrates. Our technique requires only one fluidic feature layer, one pneumatic control line and does not rely on flexible membranes and mechanical or moving parts. The presented bubble pump is therefore compatible with both elastomeric and rigid substrate materials and the associated scalable manufacturing processes. Directed liquid flow was achieved in a microchannel by an in-series configuration of two previously described "bubble gates", i.e., by gas-bubble enabled miniature gate valves. Only one time-dependent pressure signal is required and initiates at the upstream (active) bubble gate a reciprocating bubble motion. Applied at the downstream (passive) gate a time-constant gas pressure level is applied. In its rest state, the passive gate remains closed and only temporarily opens while the liquid pressure rises due to the active gate's reciprocating bubble motion. We have designed, fabricated and consistently operated our bubble pump with a variety of working liquids for >72 hours. Flow rates of 0-5.5 μl min(-1), were obtained and depended on the selected geometric dimensions, working fluids and actuation frequencies. The maximum operational pressure was 2.9 kPa-9.1 kPa and depended on the interfacial tension of the working fluids. Attainable flow rates compared favorably with those of available micropumps. We achieved flow rate enhancements of 30-100% by operating two bubble pumps in tandem and demonstrated scalability of the concept in a multi-well format with 12 individually and uniformly perfused microchannels (variation in flow rate <7%). We envision the demonstrated concept to allow for the consistent on-chip delivery of a wide range of different liquids that may even include highly reactive or moisture sensitive solutions. The presented bubble pump may provide active flow control for

  7. Hand Grasping Synergies As Biometrics.

    PubMed

    Patel, Vrajeshri; Thukral, Poojita; Burns, Martin K; Florescu, Ionut; Chandramouli, Rajarathnam; Vinjamuri, Ramana

    2017-01-01

    Recently, the need for more secure identity verification systems has driven researchers to explore other sources of biometrics. This includes iris patterns, palm print, hand geometry, facial recognition, and movement patterns (hand motion, gait, and eye movements). Identity verification systems may benefit from the complexity of human movement that integrates multiple levels of control (neural, muscular, and kinematic). Using principal component analysis, we extracted spatiotemporal hand synergies (movement synergies) from an object grasping dataset to explore their use as a potential biometric. These movement synergies are in the form of joint angular velocity profiles of 10 joints. We explored the effect of joint type, digit, number of objects, and grasp type. In its best configuration, movement synergies achieved an equal error rate of 8.19%. While movement synergies can be integrated into an identity verification system with motion capture ability, we also explored a camera-ready version of hand synergies-postural synergies. In this proof of concept system, postural synergies performed well, but only when specific postures were chosen. Based on these results, hand synergies show promise as a potential biometric that can be combined with other hand-based biometrics for improved security.

  8. Hand Grasping Synergies As Biometrics

    PubMed Central

    Patel, Vrajeshri; Thukral, Poojita; Burns, Martin K.; Florescu, Ionut; Chandramouli, Rajarathnam; Vinjamuri, Ramana

    2017-01-01

    Recently, the need for more secure identity verification systems has driven researchers to explore other sources of biometrics. This includes iris patterns, palm print, hand geometry, facial recognition, and movement patterns (hand motion, gait, and eye movements). Identity verification systems may benefit from the complexity of human movement that integrates multiple levels of control (neural, muscular, and kinematic). Using principal component analysis, we extracted spatiotemporal hand synergies (movement synergies) from an object grasping dataset to explore their use as a potential biometric. These movement synergies are in the form of joint angular velocity profiles of 10 joints. We explored the effect of joint type, digit, number of objects, and grasp type. In its best configuration, movement synergies achieved an equal error rate of 8.19%. While movement synergies can be integrated into an identity verification system with motion capture ability, we also explored a camera-ready version of hand synergies—postural synergies. In this proof of concept system, postural synergies performed well, but only when specific postures were chosen. Based on these results, hand synergies show promise as a potential biometric that can be combined with other hand-based biometrics for improved security. PMID:28512630

  9. Changes in arm-hand function and arm-hand skill performance in patients after stroke during and after rehabilitation

    PubMed Central

    Smeets, Rob Johannes Elise Marie; Seelen, Henk Alexander Maria

    2017-01-01

    Background Arm-hand rehabilitation programs applied in stroke rehabilitation frequently target specific populations and thus are less applicable in heterogeneous patient populations. Besides, changes in arm-hand function (AHF) and arm-hand skill performance (AHSP) during and after a specific and well-described rehabilitation treatment are often not well evaluated. Method This single-armed prospective cohort study featured three subgroups of stroke patients with either a severely, moderately or mildly impaired AHF. Rehabilitation treatment consisted of a Concise_Arm_and_hand_ Rehabilitation_Approach_in_Stroke (CARAS). Measurements at function and activity level were performed at admission, clinical discharge, 3, 6, 9 and 12 months after clinical discharge. Results Eighty-nine stroke patients (M/F:63/23; mean age:57.6yr (+/-10.6); post-stroke time:29.8 days (+/-20.1)) participated. All patients improved on AHF and arm-hand capacity during and after rehabilitation, except on grip strength in the severely affected subgroup. Largest gains occurred in patients with a moderately affected AHF. As to self-perceived AHSP, on average, all subgroups improved over time. A small percentage of patients declined regarding self-perceived AHSP post-rehabilitation. Conclusions A majority of stroke patients across the whole arm-hand impairment severity spectrum significantly improved on AHF, arm-hand capacity and self-perceived AHSP. These were maintained up to one year post-rehabilitation. Results may serve as a control condition in future studies. PMID:28614403

  10. Entropy, pricing and macroeconomics of pumped-storage systems

    NASA Astrophysics Data System (ADS)

    Karakatsanis, Georgios; Mamassis, Nikos; Koutsoyiannis, Demetris; Efstratiadis, Andreas

    2014-05-01

    We propose a pricing scheme for the enhancement of macroeconomic performance of pumped-storage systems, based on the statistical properties of both geophysical and economic variables. The main argument consists in the need of a context of economic values concerning the hub energy resource; defined as the resource that comprises the reference energy currency for all involved renewable energy sources (RES) and discounts all related uncertainty. In the case of pumped-storage systems the hub resource is the reservoir's water, as a benchmark for all connected intermittent RES. The uncertainty of all involved natural and economic processes is statistically quantifiable by entropy. It is the relation between the entropies of all involved RES that shapes the macroeconomic state of the integrated pumped-storage system. Consequently, there must be consideration on the entropy of wind, solar and precipitation patterns, as well as on the entropy of economic processes -such as demand preferences on either current energy use or storage for future availability. For pumped-storage macroeconomics, a price on the reservoir's capacity scarcity should also be imposed in order to shape a pricing field with upper and lower limits for the long-term stability of the pricing range and positive net energy benefits, which is the primary issue of the generalized deployment of pumped-storage technology. Keywords: Entropy, uncertainty, pricing, hub energy resource, RES, energy storage, capacity scarcity, macroeconomics

  11. Research and application of key technology of electric submersible plunger pump

    NASA Astrophysics Data System (ADS)

    Qian, K.; Sun, Y. N.; Zheng, S.; Du, W. S.; Li, J. N.; Pei, G. Z.; Gao, Y.; Wu, N.

    2018-06-01

    Electric submersible plunger pump is a new generation of rodless oil production equipment, whose improvements and upgrades of key technologies are conducive to its large-scale application and reduce the cost and improve the efficiency. In this paper, the operating mechanism of the unit in-depth study, aimed at the problems existing in oilfield production, to propose an optimization method creatively, including the optimal design of a linear motor for submersible oil, development of new double-acting load-relief pump, embedded flexible closed-loop control technology, research and development of low-cost power cables. 90 oil wells were used on field application, the average pump inspection cycle is 608 days, the longest pump check cycle has exceeded 1037 days, the average power saving rate is 45.6%. Application results show that the new technology of optimization and upgrading can further improve the reliability and adaptability of electric submersible plunger pump, reduce the cost of investment.

  12. Determinants of the Intention to Pump Breast Milk on a University Campus.

    PubMed

    Bai, Yeon K; Dinour, Lauren M; Pope, Gina A

    2016-09-01

    The number of young mothers in the workforce and in schools of higher education has steadily increased. In order to maintain a breastfeeding relationship with their children, these mothers need to pump or express breast milk multiple times a day while at work or school. This study examines the factors associated with the intention to pump breast milk at one university campus. Between January and February 2015, an online survey invitation was sent out to all female employees and students at one university. The survey, based on the Theory of Planned Behavior, assessed intentions to pump breast milk on campus. The intention to pump breast milk was examined between employees and students separately. Within these 2 groups, behavioral performers (women who pump or have pumped breast milk while on campus) were compared to nonperformers. Using multiple regression analysis, the most influential predictors of the intention to pump (ie, attitudes, subjective norm, perceived behavioral control, and underlying beliefs) were identified. A total of 218 women participated in the study (62 employees and 156 students, a 71.7% survey completion rate). Among university employees, the most influential factor that predicted pumping intention among performers was attitude toward pumping (β = 0.36, P = .03). Among student performers, the most influential factor to predict pumping intention was the subjective norm (β = 0.31, P = .02). For student nonperformers, perceived behavioral control (β = 0.54, P < .001) was the most influential factor. Important determinants of the intention to pump on campus included relieving discomfort from engorgement, availability of milk storage, experiencing other people's approval of pumping breast milk, and the inconvenience of carrying pump equipment. Continued efforts are needed to create a supportive culture for breastfeeding in the campus community as well as to provide pump loan and milk storage options for both employee and student mothers. © 2016

  13. [Pharmacogenic osteoporosis beyond cortisone. Proton pump inhibitors, glitazones and diuretics].

    PubMed

    Kann, P H; Hadji, P; Bergmann, R S

    2014-05-01

    [corrected] There are many drugs which can cause osteoporosis or at least favor its initiation. The effect of hormones and drugs with antihormonal activity, such as glucocorticoids and aromatase inhibitors, on initiation of osteoporosis is well known. In addition, proton pump inhibitors, glitazones and diuretics also influence the formation of osteoporosis. The results of currently available studies on the correlation between proton pump inhibitors, glitazones and diuretics on formation of osteoporosis were evaluated and summarized. Proton pump inhibitors and glitazones increase the risk for osteoporotic fractures. Loop diuretics may slightly increase fracture risk, whereas thiazides were shown to be osteoprotective by reducing fracture probability on a relevant scale. Proton pump inhibitors should not be prescribed without serious consideration and then only as long as necessary. Alternatively, the administration of the less effective H2 antagonists should be considered when possible due to the reduction of acid secretion. Because the long-term intake of thiazides is associated with a clinically relevant reduction in the risk of fractures and they are economic and well-tolerated, prescription can be thoroughly recommended within the framework of differential diagnostic considerations in an appropriate clinical context. The briefly increased risk of falling immediately after starting diuretic therapy is the only point which needs to be considered.

  14. Simulated effects of Lower Floridan aquifer pumping on the Upper Floridan aquifer at Rincon, Effingham County, Georgia

    USGS Publications Warehouse

    Cherry, Gregory S.; Clarke, John S.

    2015-01-01

    A steady-state simulation representing implementation of drawdown-offset-pumping reductions totaling 292 gal/min at Rincon UFA production wells 36S034 and 36S035 and pumping from the new LFA well 36S048 at 1,000 gal/min (scenario C) resulted in decreased magnitude and areal extent of drawdown in the UFA compared with scenario A. In the latter scenario, the LFA well was pumped without UFA drawdown-offset-pumping reductions. Water budgets for scenario C yielded percentage contributions from flow components that were consistent with those from scenario B. Specifically, 69 percent of the increased pumping in scenario C originated from general-head boundaries from overlying units of the surficial and Brunswick aquifer systems and the balance of flow was derived from general- and specified-head boundaries in the UFA. In all scenarios, the placement of model boundaries and type of boundary exerted the greatest control on overall groundwater flow and interaquifer leakage in the system.

  15. Smart hands for the EVA retriever

    NASA Technical Reports Server (NTRS)

    Hess, Clifford W.; Li, Larry C.

    1990-01-01

    Dexterous, robotic hands are required for the extravehicular activity retriever (EVAR) system being developed by the NASA Johnson Space Center (JSC). These hands, as part of the EVAR system, must be able to grasp objects autonomously and securely which inadvertently separate from the Space Station. Development of the required hands was initiated in 1987. Outlined here are the hand development activities, including design considerations, progress to date, and future plans. Several types of dexterous hands that were evaluated, along with a proximity-sensing capability that was developed to initiate a reflexive, adaptive grasp, are described. The evaluations resulted in the design and fabrication of a 6-degree-of-freedom (DOF) hand that has two fingers and a thumb arranged in an anthropomorphic configuration. Finger joint force and position sensors are included in the design, as well as infrared proximity sensors which allow initiation of the grasp sequence when an object is detected within the grasp envelope.

  16. Silicon micromachined pumps employing piezoelectric membrane actuation for microfluidic systems

    NASA Astrophysics Data System (ADS)

    Koch, Michael

    Microsystems technology is a rapidly expanding area that comprises electronics, mechanics and optics. In this field, physical/chemical sensing, fluid handling and optical communication are emerging as potential markets. Microfluidic systems like an implantable insulin pump, a drug delivery system and a total chemical analysis system are currently being developed by academia and industry around the world. This project contributes to the area of microfluidics in that a novel thick-film-on-silicon membrane actuator has been developed to allow inexpensive mass production of micropumps. To date piezoelectric plates have been surface mounted onto a silicon membrane. This single chip fabrication method can now be replaced by screen printing thick piezoelectric layers onto 4 inch silicon substrates. Two different pump types have been developed. These are membrane pumps with either cantilever valves or diffuser/nozzle valves. Pump rates between 100 and 200 μl min-1 and backpressures up to 4 kPa have been achieved with these pumps. Along with the technology of micropumps, simulators have been developed. A novel coupled FEM-CFD solver was realised by a computer controlled coupling of two commercially available packages (ANSYS and CFX-Flow3D). The results of this simulator were in good agreement with measurements on micromachined cantilever valves. CFX- Flow3D was also used to successfully model the behaviour of the diffuser/nozzle valve. Finally, the pump has been simulated using a continuity equation. A behavioural dynamic extension of the cantilever valve was necessary to achieve better prediction of the pump rates for higher frequencies. As well, a common process has been developed for microfluidic devices like micromixers, particle counters and sorters as well as flow sensors. The micromixer has been tested already and achieves mixing for input pressures between 2 and 7 kPa. This agrees with simulations of the diffusive mixing with CFX-Flow3D. Together with the micropump

  17. Off-pump versus on-pump coronary artery revascularization: effects on pulmonary function.

    PubMed

    e Silva, Ana M R P; Saad, Roberto; Stirbulov, Roberto; Rivetti, Luiz A

    2010-07-01

    Many studies have shown important changes in lung function tests after coronary artery surgeries. It is controversial if off-pump surgery can give a better and shorter recovery than the on-pump. A prospective study was conducted on 42 patients submitted to coronary artery surgery and divided into two groups: 21 off-pump using intraluminal shunt (G (I)) and 21 on-pump (G (II)), matched by the anatomical location of the coronary arteries lesions. All patients had spirometric evaluation, blood gas measurements and alveolo-arterial oxygen gradient (A-aDO(2)), at the fourth and 10th postoperative days (PO(4) and PO(10)). Preoperatively, G(I) and G(II) had similar results (P>0.372). Spirometry showed decreases at PO(4) and remained decreased until PO(10) for both groups, with significant differences between the groups. The blood gas measurements showed reduction in arterial oxygen pressure (PaO(2)) and carbon dioxide pressure (PaCO(2)), while there was an increase in A-aDO(2) at PO(4) and PO(10) in both groups. The results suggest that different changes occur in pulmonary function when the surgery is performed with or without cardiopulmonary bypass. The off-pump patients showed significantly greater improvement than the on-pump group.

  18. Risk Factors of On-Pump Conversion during Off-Pump Coronary Artery Bypass Graft

    PubMed Central

    Yoon, Sung Sil; Bang, Jung Hee; Jeong, Sang Seok; Jeong, Jae Hwa; Woo, Jong Soo

    2017-01-01

    Background Off-pump coronary artery bypass grafting (OPCABG) procedures can avoid the complications of an on-pump bypass. However, some cases unexpectedly require conversion to cardiopulmonary bypass during OPCABG. The risk factors associated with a sudden need for cardiopulmonary bypass were analyzed. Methods This retrospective study included 283 subjects scheduled for OPCABG from 2001 to 2010. These were divided into an OPCABG group and an on-pump conversion group. Preoperative, operative, and postoperative variables were compared between the 2 groups. Results Of the 283 patients scheduled for OPCABG, 47 (16%) were switched to on-pump coronary artery bypass grafting (CABG). The mortality of the both the OPCABG and on-pump conversion groups was not significantly different. The major risk factors for conversion to on-pump CABG were congestive heart failure (CHF) (odds ratio [OR], 3.5; p=0.029), ejection fraction (EF) <35% (OR, 4.4; p=0.012), and preoperative beta-blocker (BB) administration (OR, 0.3; p=0.007). The use of intraoperative (p=0.007) and postoperative (p=0.021) inotropics was significantly higher in the conversion group. The amount of postoperative drainage (p<0.001) and transfusion (p<0.001) also was significantly higher in the conversion group. There were no significant differences in stroke or cardiovascular complications between the groups over the course of short-term and long-term follow-up. Conclusion Patients who undergo OPCABG and have CHF or a lower EF (<35%) are more likely to undergo on-pump conversion, while preoperative BB administration could help prevent conversions from OPCABG to on-pump CABG. PMID:29124027

  19. Diode-laser-pump module with integrated signal ports for pumping amplifying fibers and method

    DOEpatents

    Savage-Leuchs,; Matthias, P [Woodinville, WA

    2009-05-26

    Apparatus and method for collimating pump light of a first wavelength from laser diode(s) into a collimated beam within an enclosure having first and second optical ports, directing pump light from the collimated beam to the first port; and directing signal light inside the enclosure between the first and second port. The signal and pump wavelengths are different. The enclosure provides a pump block having a first port that emits pump light to a gain fiber outside the enclosure and that also passes signal light either into or out of the enclosure, and another port that passes signal light either out of or into the enclosure. Some embodiments use a dichroic mirror to direct pump light to the first port and direct signal light between the first and second ports. Some embodiments include a wavelength-conversion device to change the wavelength of at least some of the signal light.

  20. Using Self Potential and Multiphase Flow Modeling to Optimize Groundwater Pumping

    NASA Astrophysics Data System (ADS)

    Gasperikova, E.; Zhang, Y.; Hubbard, S.

    2008-12-01

    Numerical and field hydrological and geophysical studies have been conducted to investigate the impact of groundwater pumping on near-river hydrology for a segment of the Russian River at the Wohler Site, California, which is a riverbed filtration system managed by the Sonoma County Water Agency. Groundwater pumping near streams can cause a creation of unsaturated regions and hence reduce the pumping capacity and change the flow paths. A three-dimensional multiphase flow and transport model can be calibrated to the temperature, and water levels at monitoring wells based on known pumping rates, and the river stage. Streaming (self) potential (SP) is one of the electrokinetic processes that describes the coupled behavior of hydraulic and electrical flow within a porous medium, and is easily measured on the surface or in boreholes. Observing temporal and spatial variations in geophysical signatures provides a powerful approach for monitoring changes in the natural systems due to natural or forced (pumping) system perturbations. Geophysical and hydrological data were collected before, during and after a pumping experiment at the Wohler Site. Using this monitoring dataset, we illustrate how loose coupling between hydrogeological and geophysical (SP) processes and data can be used to calibrate the flow model and to optimize pumping schedules as needed to guide sustainable water resource development.

  1. 46 CFR 64.93 - Pump controls.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Pump controls. 64.93 Section 64.93 Shipping COAST GUARD... SYSTEMS Cargo Handling System § 64.93 Pump controls. (a) A pressure gauge must be installed— (1) On the pump discharge; (2) Near the pump controls; and (3) Visible to the operator. (b) A pump must have a...

  2. 46 CFR 64.93 - Pump controls.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Pump controls. 64.93 Section 64.93 Shipping COAST GUARD... SYSTEMS Cargo Handling System § 64.93 Pump controls. (a) A pressure gauge must be installed— (1) On the pump discharge; (2) Near the pump controls; and (3) Visible to the operator. (b) A pump must have a...

  3. 46 CFR 64.93 - Pump controls.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Pump controls. 64.93 Section 64.93 Shipping COAST GUARD... SYSTEMS Cargo Handling System § 64.93 Pump controls. (a) A pressure gauge must be installed— (1) On the pump discharge; (2) Near the pump controls; and (3) Visible to the operator. (b) A pump must have a...

  4. 46 CFR 64.93 - Pump controls.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Pump controls. 64.93 Section 64.93 Shipping COAST GUARD... SYSTEMS Cargo Handling System § 64.93 Pump controls. (a) A pressure gauge must be installed— (1) On the pump discharge; (2) Near the pump controls; and (3) Visible to the operator. (b) A pump must have a...

  5. 46 CFR 64.93 - Pump controls.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Pump controls. 64.93 Section 64.93 Shipping COAST GUARD... SYSTEMS Cargo Handling System § 64.93 Pump controls. (a) A pressure gauge must be installed— (1) On the pump discharge; (2) Near the pump controls; and (3) Visible to the operator. (b) A pump must have a...

  6. Brightness enhancement limits in pulsed cladding-pumped fiber Raman amplifiers

    NASA Astrophysics Data System (ADS)

    Ji, Junhua; Codemard, Christophe A.; Nilsson, Johan

    2010-02-01

    We analyze theoretically limitations on brightness enhancement of a multimode pump beam into a diffraction-limited Stokes beam in efficient cladding-pumped fiber Raman amplifiers. Firstly, the power-scaling of the 1st Stokes (hence the brightness enhancement) is limited by the generation of the 2nd order Stokes. Thus using a spectral waveguide filter such as a W-type fiber core, it is possible to improve this limit to nearly five times that of a normal fiber without spectral filter. Secondly, we analyze limits set by glass damage, propagation loss, and pump-signal pulse walk-off in the multimode fiber. We show that a well-designed fiber with a propagation loss of 3.5 dB/km allows for a pump-to-signal brightness improvement of over 1000 times for pulses longer than 40 ns and up to 3500 times in the cw regime.

  7. Experimental analysis of direct-expansion ground-coupled heat pump systems

    NASA Astrophysics Data System (ADS)

    Mei, V. C.; Baxter, V. D.

    1991-09-01

    Direct-expansion ground-coil-coupled (DXGC) heat pump systems have certain energy efficiency advantages over conventional ground-coupled heat pump (GCHP) systems. Principal among these advantages are that the secondary heat transfer fluid heat exchanger and circulating pump are eliminated. While the DXGC concept can produce higher efficiencies, it also produces more system design and environmental problems (e.g., compressor starting, oil return, possible ground pollution, and more refrigerant charging). Furthermore, general design guidelines for DXGC systems are not well documented. A two-pronged approach was adopted for this study: (1) a literature survey, and (2) a laboratory study of a DXGC heat pump system with R-22 as the refrigerant, for both heating and cooling mode tests done in parallel and series tube connections. The results of each task are described in this paper. A set of general design guidelines was derived from the test results and is also presented.

  8. Brady Well Coordinates and Observation Sensor Depths

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    David Lim

    Contains metadata associated with the wells used in the 2016 Spring Campaign led partially by UW - Madison, LBNL, and LLNL scientists. Included with the well coordinates are the depths to the pressure sensors used in observation and pumping wells. Read me files are included for each .csv file.

  9. Keeping Hearts Pumping

    NASA Technical Reports Server (NTRS)

    2002-01-01

    A collaboration between NASA, Dr. Michael DeBakey, Dr. George Noon, and MicroMed Technology, Inc., resulted in a life-saving heart pump for patients awaiting heart transplants. The MicroMed DeBakey VAD functions as a "bridge to heart transplant" by pumping blood throughout the body to keep critically ill patients alive until a donor heart is available. Weighing less than 4 ounces and measuring 1 inch by 3 inches, the pump is approximately one-tenth the size of other currently marketed pulsatile VADs. This makes it less invasive and ideal for smaller adults and children. Because of the pump's small size, less than 5 percent of the patients implanted developed device-related infections. It can operate up to 8 hours on batteries, giving patients the mobility to do normal, everyday activities.The MicroMed DeBakey VAD is a registered trademark of MicroMed Technology, Inc.

  10. Mentor's hand hygiene practices influence student's hand hygiene rates.

    PubMed

    Snow, Michelle; White, George L; Alder, Stephen C; Stanford, Joseph B

    2006-02-01

    There were 3 objectives for this prospective quasiexperimental study. The first was to determine the effect of mentor's hand hygiene practices on student's hand hygiene rates during clinical rotations. The second was to assess the difference in hand hygiene rates for students with and without prior medical experience. The third was to assess the student's opinion and beliefs regarding hand hygiene. Sixty students enrolled in a certified nursing program were selected to participate in the study. Each study group was observed twice during the 30-day span. The first observational period was conducted on day 1 of clinical rotation. The second observational period was conducted on day 30 of clinical rotation. Students were observed for hand hygiene. Also assessed were medical experience, sex, gloving, age, and mentor's hand hygiene practices. After observational period 2, a brief questionnaire was given to students to determine their opinion and beliefs regarding hand hygiene. The questionnaire was divided into 5 sections: student's commitment to hand hygiene, their perception of hand hygiene inconvenience, the necessity of hand hygiene, the student's ability to perform hand hygiene, and their opinion on the frequency of medical staff's hand hygiene. The mentor's practice of hand hygiene was the strongest predictor of the student's rate of hand hygiene for both observational periods (P < .01). Furthermore, students without prior medical experience had a significant increase in hand hygiene rates when comparing observational period 1 to observational period 2 (P < .01). Glove usage was associated with increased hand hygiene rates by 50% during observational period 1 (P = .01) and 44% during observational period 2 (P < .01). Male students during observational period 1 practiced hand hygiene 30% less often than female students (P < .01); however, during observational period 2, there was no significant difference between hand hygiene rates for males and females (P = .82

  11. Thermally Actuated Hydraulic Pumps

    NASA Technical Reports Server (NTRS)

    Jones, Jack; Ross, Ronald; Chao, Yi

    2008-01-01

    Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research

  12. EXEIS - Expert Screening and Optimal Extraction/Injection Pumping Systems for Short-Term Plume Immobilization

    DTIC Science & Technology

    1990-05-01

    i at time t, (L). hL lower limit on head at pump i, (L). i xviii hU upper limit on head at -’ump i, (L).i (h j ,TT) d head at observation well j which...constraints: L U hL U h .. (9) h. ih. i ...I hi,t 1 S(hj Q........................(10) J ho ,TT - (h ,TT ) d . . . . .. . . . . . .O where: I = total number...at pump i at time period t, (L); = hi, 0 -s i,t hU = upper limit on head at pump i, (L); 1 (hTT ) d = head at each observation well j which is down

  13. Simulation and automation of thermal processes in oil well

    NASA Astrophysics Data System (ADS)

    Kostarev, N. A.; Trufanova, N. M.

    2018-03-01

    The paper presents a two-dimensional mathematical model and a numerical analysis of heat and mass transfer processes in an oil well. The proposed and implemented mathematical model of the process of heat and mass transfer in an oil well allows analyzing the temperature field in the whole space of an oil well and is suitable for any fields equipped with an electric centrifugal pump. Temperature and velocity fields were obtained, as well as the distribution of temperature on the wall of the pump tubing along the depth of the well. On the basis of the obtained temperature fields, the modes of periodic heating of the well by the heating cable were developed. Recommendations are given on the choice of power parameters and the time of warming up the well.

  14. Rotary blood pump

    NASA Technical Reports Server (NTRS)

    Benkowski, Robert J. (Inventor); Kiris, Cetin (Inventor); Kwak, Dochan (Inventor); Rosenbaum, Bernard J. (Inventor); Bacak, James W. (Inventor); DeBakey, Michael E. (Inventor)

    1999-01-01

    A blood pump that comprises a pump housing having a blood flow path therethrough, a blood inlet, and a blood outlet; a stator mounted to the pump housing, the stator having a stator field winding for producing a stator magnetic field; a flow straightener located within the pump housing, and comprising a flow straightener hub and at least one flow straightener blade attached to the flow straightener hub; a rotor mounted within the pump housing for rotation in response to the stator magnetic field, the rotor comprising an inducer and an impeller; the inducer being located downstream of the flow straightener, and comprising an inducer hub and at least one inducer blade attached to the inducer hub; the impeller being located downstream of the inducer, and comprising an impeller hub and at least one impeller blade attached to the impeller hub; and preferably also comprising a diffuser downstream of the impeller, the diffuser comprising a diffuser hub and at least one diffuser blade. Blood flow stagnation and clot formation within the pump are minimized by, among other things, providing the inducer hub with a diameter greater than the diameter of the flow straightener hub; by optimizing the axial spacing between the flow straightener hub and the inducer hub, and between the impeller hub and the diffuser hub; by optimizing the inlet angle of the diffuser blades; and by providing fillets or curved transitions between the upstream end of the inducer hub and the shaft mounted therein, and between the impeller hub and the shaft mounted therein.

  15. Tracking reaction dynamics in solution by pump-probe X-ray absorption spectroscopy and X-ray liquidography (solution scattering).

    PubMed

    Kim, Jeongho; Kim, Kyung Hwan; Oang, Key Young; Lee, Jae Hyuk; Hong, Kiryong; Cho, Hana; Huse, Nils; Schoenlein, Robert W; Kim, Tae Kyu; Ihee, Hyotcherl

    2016-03-07

    Characterization of transient molecular structures formed during chemical and biological processes is essential for understanding their mechanisms and functions. Over the last decade, time-resolved X-ray liquidography (TRXL) and time-resolved X-ray absorption spectroscopy (TRXAS) have emerged as powerful techniques for molecular and electronic structural analysis of photoinduced reactions in the solution phase. Both techniques make use of a pump-probe scheme that consists of (1) an optical pump pulse to initiate a photoinduced process and (2) an X-ray probe pulse to monitor changes in the molecular structure as a function of time delay between pump and probe pulses. TRXL is sensitive to changes in the global molecular structure and therefore can be used to elucidate structural changes of reacting solute molecules as well as the collective response of solvent molecules. On the other hand, TRXAS can be used to probe changes in both local geometrical and electronic structures of specific X-ray-absorbing atoms due to the element-specific nature of core-level transitions. These techniques are complementary to each other and a combination of the two methods will enhance the capability of accurately obtaining structural changes induced by photoexcitation. Here we review the principles of TRXL and TRXAS and present recent application examples of the two methods for studying chemical and biological processes in solution. Furthermore, we briefly discuss the prospect of using X-ray free electron lasers for the two techniques, which will allow us to keep track of structural dynamics on femtosecond time scales in various solution-phase molecular reactions.

  16. Heat-Powered Pump for Liquid Metals

    NASA Technical Reports Server (NTRS)

    Campana, R. J.

    1986-01-01

    Proposed thermoelectromagnetic pump for liquid metal powered by waste heat; needs no battery, generator, or other external energy source. Pump turns part of heat in liquid metal into pumping energy. In combination with primary pump or on its own, thermoelectric pump circulates coolant between reactor and radiator. As long as there is decay heat to be removed, unit performs function.

  17. Thermomechanical piston pump development

    NASA Technical Reports Server (NTRS)

    Sabelman, E. E.

    1971-01-01

    A thermally powered reciprocating pump has been devised to replace or augment an electric pump for the transport of temperature-control fluid on the Thermoelectric Outer Planet Spacecraft (TOPS). The thermally powered pump operates cyclically by extracting heat energy from the fluid by means of a vapor-pressure expansion system and by using the heat to perform the mechanical work of pumping. A feasibility test unit has been constructed to provide an output of 7 cu in during a 10- to 100-second cycle. It operates with a fluid input temperature of 200 to 300 F and a heat sink temperature of 0 to 30 F.

  18. Conditioning geostatistical simulations of a heterogeneous paleo-fluvial bedrock aquifer using lithologs and pumping tests

    NASA Astrophysics Data System (ADS)

    Niazi, A.; Bentley, L. R.; Hayashi, M.

    2016-12-01

    Geostatistical simulations are used to construct heterogeneous aquifer models. Optimally, such simulations should be conditioned with both lithologic and hydraulic data. We introduce an approach to condition lithologic geostatistical simulations of a paleo-fluvial bedrock aquifer consisting of relatively high permeable sandstone channels embedded in relatively low permeable mudstone using hydraulic data. The hydraulic data consist of two-hour single well pumping tests extracted from the public water well database for a 250-km2 watershed in Alberta, Canada. First, lithologic models of the entire watershed are simulated and conditioned with hard lithological data using transition probability - Markov chain geostatistics (TPROGS). Then, a segment of the simulation around a pumping well is used to populate a flow model (FEFLOW) with either sand or mudstone. The values of the hydraulic conductivity and specific storage of sand and mudstone are then adjusted to minimize the difference between simulated and actual pumping test data using the parameter estimation program PEST. If the simulated pumping test data do not adequately match the measured data, the lithologic model is updated by locally deforming the lithology distribution using the probability perturbation method and the model parameters are again updated with PEST. This procedure is repeated until the simulated and measured data agree within a pre-determined tolerance. The procedure is repeated for each well that has pumping test data. The method creates a local groundwater model that honors both the lithologic model and pumping test data and provides estimates of hydraulic conductivity and specific storage. Eventually, the simulations will be integrated into a watershed-scale groundwater model.

  19. Multi-stage internal gear/turbine fuel pump

    DOEpatents

    Maier, Eugen; Raney, Michael Raymond

    2004-07-06

    A multi-stage internal gear/turbine fuel pump for a vehicle includes a housing having an inlet and an outlet and a motor disposed in the housing. The multi-stage internal gear/turbine fuel pump also includes a shaft extending axially and disposed in the housing. The multi-stage internal gear/turbine fuel pump further includes a plurality of pumping modules disposed axially along the shaft. One of the pumping modules is a turbine pumping module and another of the pumping modules is a gerotor pumping module for rotation by the motor to pump fuel from the inlet to the outlet.

  20. Back to basics: hand hygiene and surgical hand antisepsis.

    PubMed

    Spruce, Lisa

    2013-11-01

    Health care-associated infections (HAIs) are a significant issue in the United States and throughout the world, but following proper hand hygiene practices is the most effective and least expensive way to prevent HAIs. Hand hygiene is inexpensive and protects patients and health care personnel alike. The four general types of hand hygiene that should be performed in the perioperative environment are washing hands that are visibly soiled, hand hygiene using alcohol-based products, surgical hand scrubs, and surgical hand scrubs using an alcohol-based surgical hand rub product. Barriers to proper hand hygiene may include not thinking about it, forgetting, skin irritation, a lack of role models, or a lack of a safety culture. One strategy for improving hand hygiene practices is monitoring hand hygiene as part of a quality improvement project, but the most important aspect for perioperative team members is to set an example for other team members by following proper hand hygiene practices and reminding each other to perform hand hygiene. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  1. Hydraulic and Thermal Response to Intermittent Pumping in Unconfined Alluvial Aquifers along a Regulated Stream

    NASA Astrophysics Data System (ADS)

    Maharjan, Madan

    Groundwater response to stream stage fluctuations was studied using a year-long time series of stream stage and well heads in Glen Dale and New Martinsville, WV. Stream stage fluctuations exerted primary control over groundwater levels, especially during high flows. The location and operation of river pools created by dams alter groundwater flow paths and velocities. Aquifers are more prone to surface water infiltration in the upper reaches of pools than in lower reaches. Aquifer diffusivity is heterogeneous within and between the two sites. Temperature fluctuations were observed for 2.5 years in 14 wells in three alluvial aquifers. Temperature signals have 2 components corresponding to pump-on and pump-off periods. Both components vary seasonality at different magnitudes. While pump-off temperatures fluctuated up to 3.8o C seasonally, short-term temperature shifts induced by turning the pump on were 0.2 to 2.5o C. Pumping-induced temperature shifts were highest in magnitude in summer and winter. Groundwater temperature lagged behind that of surface water by approximately six months. Pumping induced and seasonal temperature shifts were spatially and temporally complex but indicate stream exfiltration is a major driver for a number of these wells. Numerical simulation of aquifer response to pumping show different conditions before and after well-field development. During pre-development, the stream was losing at high flow and gaining at low flow. During post-development, however, the stream was losing at high flow and spatially variable at low flow. While bank storage gained only during high stage, stream exfiltration occurred year-round. Pumping induced stream exfiltration by creating an extensive cone of depression beneath the stream in both upstream and downstream directions. Spatially and temporally variable groundwater-surface water interaction next to a regulated stream were studied using analytical and numerical models, based on field observations

  2. Theoretical model and simulations for a cw exciplex pumped alkali laser.

    PubMed

    Huang, Wei; Tan, Rongqing; Li, Zhiyong; Lu, Xiaochuan

    2015-12-14

    The Exciplex Pumped Alkali Laser (XPAL) system, which is similar to DPAL (Diode Pumped Alkali vapor Laser), has been demonstrated in mixtures of Cs vapor, Ar, with and without ethane. Unlike DPAL, it uses the broadband absorption blue satellite of the alkali D2 line, created by naturally occuring collision pairs. For example, Cs-Ar collision pairs have an absorption width which is as wide as the one of commercial semiconductor diode lasers. A continuous wave XPAL four-level theoretical model is presented in this paper. More factors are considered, such as the spectral dependence of pumped laser absorption for broadband pumping and the longitudinal population variation. Some intra-cavity details, such as longitudinal distributions of pumped laser and alkali laser, can also be solved well. The predictions of optical-to-optical efficiency as a function of temperature and pumped laser intensity are presented. The model predicts that there is an optimum value of temperature or pumped laser intensity. The analysis of the influence of cell length on optical-to-optical efficiency shows that a better performance can be achieved when using longer cell. The prediction of influence of Ar concentration and reflectivity of output coupler shows that higher optical-to-optical efficiency could be achieved if lower reflectivity of output coupler and higher Ar concentration are used. The optical-to-optical efficiency as high as 84% achieved by optimizing configuration with the pumped intensity of 5 × 10⁷ W/cm² presented shows that broadband pumped four-level XPAL system has a potential of high optical-to-optical efficiency.

  3. Design and evaluation of a single-pivot supported centrifugal blood pump.

    PubMed

    Yoshino, M; Uemura, M; Takahashi, K; Watanabe, N; Hoshi, H; Ohuchi, K; Nakamura, M; Fujita, H; Sakamoto, T; Takatani, S

    2001-09-01

    In order to develop a centrifugal blood pump that meets the requirements of a long-term, implantable circulatory support device, in this study a single-pivot bearing supported centrifugal blood pump was designed to evaluate its basic performance. The single-pivot structure consisted of a ceramic ball male pivot mounted on the bottom surface of the impeller and a polyethylene female pivot incorporated in the bottom pump casing. The follower magnet mounted inside the impeller was magnetically coupled to the driver magnet mounted on the shaft of the direct current brushless motor. As the motor rotated, the impeller rotated supported entirely by a single-pivot bearing system. The static pump performance obtained in the mock circulatory loop revealed an acceptable performance as a left ventricular assist device in terms of flow and head pressure. The pump flow of 5 L/min against the head pressure of 100 mm Hg was obtained at rotational speeds of 2,000 to 2,200 rpm. The maximum pump flow was 9 L/min with 2,200 rpm. The maximum electrical-to-hydraulic power conversion efficiency was around 14% at pump flows of 4 to 5 L/min. The stability of the impeller was demonstrated at the pump rpm higher than 1,400 with a single-pivot bearing without an additional support at its top. The single-pivot supported centrifugal pump can provide adequate flow and pressure as a ventricular assist device, but its mechanical stability and hemolytic as well as thrombotic performances must be tested prior to clinical use.

  4. High pressure liquid gas pump

    NASA Technical Reports Server (NTRS)

    Acres, R. L.

    1972-01-01

    Design and development of two types of pumps for handling liquefied gases are discussed. One pump uses mechanical valve shift and other uses pneumatic valve shift. Illustrations of pumps are provided and detailed description of operation is included.

  5. Publications - GMC 408 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    locations, and sampling report for the Picnic Creek/Hot (boreholes 1, 2, and 7) and Sun (boreholes 2, 3, 4 , drill collar locations, and sampling report for the Picnic Creek/Hot (boreholes 1, 2, and 7) and Sun

  6. Miniature Lightweight Ion Pump

    NASA Technical Reports Server (NTRS)

    Sinha, Mahadeva P.

    2010-01-01

    This design offers a larger surface area for pumping of active gases and reduces the mass of the pump by eliminating the additional vacuum enclosure. There are three main components to this ion pump: the cathode and anode pumping elements assembly, the vacuum enclosure (made completely of titanium and used as the cathode and maintained at ground potential) containing the assembly, and the external magnet. These components are generally put in a noble diode (or differential) configuration of the ion pump technology. In the present state of the art, there are two cathodes, one made of titanium and the other of tantalum. The anodes are made up of an array of stainless steel cylinders positioned between the two cathodes. All the elements of the pump are in a vacuum enclosure. After the reduction of pressure in this enclosure to a few microns, a voltage is applied between the cathode and the anode elements. Electrons generated by the ionization are accelerated toward the anodes that are confined in the anode space by the axial magnetic field. For the generation of the axial field along the anode elements, the magnet is designed in a C-configuration and is fabricated from rare earth magnetic materials (Nd-B-Fe or Sm-Co) possessing high energy product values, and the yoke is fabricated from the high permeability material (Hiperco-50A composed of Fe-Co-V). The electrons in this region collide with the gas molecules and generate their positive ions. These ions are accelerated into the cathode and eject cathode material (Ti). The neutral atoms deposit on the anode surfaces. Because of the chemical activity of Ti, the atoms combine with chemically active gas molecules (e.g. N2, O2, etc.) and remove them. New layers of Ti are continually deposited, and the pumping of active gases is thus accomplished. Pumping of the inert gases is accomplished by their burial several atomic layers deep into the cathode. However, they tend to re-emit if the entrapping lattice atoms are

  7. Optical vortex generation from a diode-pumped alexandrite laser

    NASA Astrophysics Data System (ADS)

    Thomas, G. M.; Minassian, A.; Damzen, M. J.

    2018-04-01

    We present the demonstration of an optical vortex mode directly generated from a diode-pumped alexandrite slab laser, operating in the bounce geometry. This is the first demonstration of an optical vortex mode generated from an alexandrite laser or from any other vibronic laser. An output power of 2 W for a vortex mode with a ‘topological charge’ of 1 was achieved and the laser was made to oscillate with both left- and right-handed vorticity. The laser operated at two distinct wavelengths simultaneously, 755 and 759 nm, due to birefringent filtering in the alexandrite gain medium. The result offers the prospect of broadly wavelength tunable vortex generation directly from a laser.

  8. Heat pump study: Tricks of the trade that can pump up efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenkins, V.

    Two years ago, many homeowners in an area near Auburn, California were unhappy with their heat pumps. The local utility, Pacific Gas Electric (PG E), received unusually large numbers of complaints from them of high electricity bills and poor system operation. PG E wanted to know whether correctable mechanical problems were to blame. It hired John Proctor, then of Building Resources Management Corp., to design and implement a study to address the heat pump customers' complaints. The Pacific Gas Electric Heat Pump Efficiency and Super Weatherization Pilot Project was the result. The first objective of the Pilot Project was tomore » identify the major problems and their prevalence in the existing residential heat pump installations. The second was to design a correction strategy that would cost PG E $400 or less per site. Participating homeowners would also share some of the costs. Project goals were improved homeowner comfort and satisfaction, increased energy efficiency of mechanical systems, and 10-20% space heating energy savings. By improving system operations, the project wished to increase customer acceptance of heat pumps in general.« less

  9. Capillary pumping independent of the liquid surface energy and viscosity

    NASA Astrophysics Data System (ADS)

    Guo, Weijin; Hansson, Jonas; van der Wijngaart, Wouter

    2018-03-01

    Capillary pumping is an attractive means of liquid actuation because it is a passive mechanism, i.e., it does not rely on an external energy supply during operation. The capillary flow rate generally depends on the liquid sample viscosity and surface energy. This poses a problem for capillary-driven systems that rely on a predictable flow rate and for which the sample viscosity or surface energy are not precisely known. Here, we introduce the capillary pumping of sample liquids with a flow rate that is constant in time and independent of the sample viscosity and sample surface energy. These features are enabled by a design in which a well-characterized pump liquid is capillarily imbibed into the downstream section of the pump and thereby pulls the unknown sample liquid into the upstream pump section. The downstream pump geometry is designed to exert a Laplace pressure and fluidic resistance that are substantially larger than those exerted by the upstream pump geometry on the sample liquid. Hence, the influence of the unknown sample liquid on the flow rate is negligible. We experimentally tested pumps of the new design with a variety of sample liquids, including water, different samples of whole blood, different samples of urine, isopropanol, mineral oil, and glycerol. The capillary filling speeds of these liquids vary by more than a factor 1000 when imbibed to a standard constant cross-section glass capillary. In our new pump design, 20 filling tests involving these liquid samples with vastly different properties resulted in a constant volumetric flow rate in the range of 20.96-24.76 μL/min. We expect this novel capillary design to have immediate applications in lab-on-a-chip systems and diagnostic devices.

  10. The Picnic Basket.

    ERIC Educational Resources Information Center

    Stirling, Nora; DiMichael, Salvatore

    The one-act play dramatizes the problems and possibilities of the rehabilitation of the mentally ill, particularly the discharged patient from state mental hospitals. It creates characters with familiar prototypes, underlining a situation in which a discharged mental patient finds a job with the help of a rehabilitation counselor and encounters…

  11. Prediction of pump cavitation performance

    NASA Technical Reports Server (NTRS)

    Moore, R. D.

    1974-01-01

    A method for predicting pump cavitation performance with various liquids, liquid temperatures, and rotative speeds is presented. Use of the method requires that two sets of test data be available for the pump of interest. Good agreement between predicted and experimental results of cavitation performance was obtained for several pumps operated in liquids which exhibit a wide range of properties. Two cavitation parameters which qualitatively evaluate pump cavitation performance are also presented.

  12. Evaluation of Rehabilitation Efficiency of Clogged wells drilled in fractured bedrock and alluvium

    NASA Astrophysics Data System (ADS)

    Lee, C.; Hamm, S.; Lee, J.; Ok, S.; Han, S.; Choo, C.; Kim, M.

    2011-12-01

    In Korea, more than one million of groundwater wells have been developed since 1990s. However, the groundwater wells have not been properly managed. Moreover, the importance of well maintenance and well rehabilitation has not been well recognized. In this circumstance, groundwater wells are usually terminated in 20-year operation due to well clogging, groundwater pollution, land use change, etc. which are originated from physical, chemical, biological, and artificial changes of and around the wells. The clogged state of the wells with diminished amount down to 80-85% can be ameliorated by various rehabilitation techniques as increasing discharge amount as well as extending the durability of the wells. In European countries and the USA, rehabilitation techniques of the clogged wells have been developed with understanding the cause and prevention of well bore clogging since 1990s. In recent years, the Korean Ministry of Environment (KME) recognized the importance of well rehabilitation. Under the support of the KME, this study evaluated the efficieny of rehabilitation using air surging, high-pressure water injection, brush & air surging, and explosive charge methods as applying to seven wells installed in fractured granite of Mt. Geumjeong and one well drilled in alluvial deposit of the Jeungsan-Ri area, Gyeongnam Province in the southeastern part of Korea. Hydraulic conductivity was estimated by using slug and pumping tests before and after well rehabilitation in order to assess physical, chemical, and biological changes of the wells. Hydraulic conductivity and pumping capacity of fractured bedrock are closely related to fracture characteristics such as fracture aperture, frequency, length, orientation, dip angle, interconnectivity, plane features, and filling materials. The evolution of clogging and filling of materials on and around the well makes decrease hydraulic conductivity and pumping capacity of the well. In this study, in addition of hydraulic conductivity

  13. Quantum behaviour of open pumped and damped Bose-Hubbard trimers

    NASA Astrophysics Data System (ADS)

    Chianca, C. V.; Olsen, M. K.

    2018-01-01

    We propose and analyse analogs of optical cavities for atoms using three-well inline Bose-Hubbard models with pumping and losses. With one well pumped and one damped, we find that both the mean-field dynamics and the quantum statistics show a qualitative dependence on the choice of damped well. The systems we analyse remain far from equilibrium, although most do enter a steady-state regime. We find quadrature squeezing, bipartite and tripartite inseparability and entanglement, and states exhibiting the EPR paradox, depending on the parameter regimes. We also discover situations where the mean-field solutions of our models are noticeably different from the quantum solutions for the mean fields. Due to recent experimental advances, it should be possible to demonstrate the effects we predict and investigate in this article.

  14. Numerical study on the responses of groundwater and strata to pumping and recharge in a deep confined aquifer

    NASA Astrophysics Data System (ADS)

    Zhang, Yang-Qing; Wang, Jian-Hua; Chen, Jin-Jian; Li, Ming-Guang

    2017-05-01

    Groundwater drawdown and strata settlements induced by dewatering in confined aquifers can be relieved by artificial recharge. In this study, numerical simulations of a field multi-well pumping-recharge test in a deep confined aquifer are conducted to analyze the responses of groundwater and strata to pumping and recharge. A three-dimensional numerical model is developed in a finite-difference software, which considers the fluid-mechanical interaction using the Biot consolidation theory. The predicted groundwater drawdown and ground settlements are compared to the measured data to confirm the validation of the numerical analysis of the pumping and recharge. Both numerical results and measured data indicate that the effect of recharge on controlling the groundwater drawdown and strata settlements correlates with the injection rate and well arrangements. Since the groundwater drawdown induced by pumping can be controlled by artificial recharge, soil compression can be relieved by reducing the changes of effective stress of the soils. Consequently, strata settlement induced by pumping can be relieved by artificial recharge and ground settlements can be eliminated if an appropriate injection rate and well arrangement are being determined. Moreover, the changes of the pore pressure and seepage force induced by pumping and recharge will also result in significant horizontal deformations in the strata near the recharge wells.

  15. A Mini Axial and a Permanent Maglev Radial Heart Pump§

    PubMed Central

    Qian, Kun-Xi; Ru, Wei-Min; Wang, Hao; Jing, Teng

    2007-01-01

    The implantability and durability have been for decades the focus of artificial heart R&D. A mini axial and a maglev radial pump have been developed to meet with such requirements. The mini axial pump weighing 27g (incl.5g rotor) has an outer diameter of 21mm and a length of 10mm in its largest point, but can produce a maximal blood flow of 6l/min with 50mmHg pressure increase. Therefore, it is suitable for the patients of 40-60kg body weight. For other patients of 60-80kg or 80-100kg body weight, the mini axial pumps of 23mm and 25mm outer diameter had been developed before, these devices were acknowledged to be the world smallest LVADs by Guinness World Record Center in 2004. The permanent maglev radial pump weighing 150g is a shaft-less centrifugal pump with permanent magnetic bearings developed by the author. It needs no second coil for suspension of the rotor except the motor coil, different from all other maglev pumps developed in USA, Japan, European, etc. Thus no detecting and controlling systems as well as no additional power supply for maglev are necessary. The pump can produce a blood flow up to as large as 10l/min against 100mmHg pressure. An implantable and durable blood pump will be a viable alternative to natural donor heart for transplantation. PMID:19662120

  16. A compact cryogenic pump

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Gang; Caldwell, Shane; Clark, Jason A.

    2016-04-01

    A centrifugal cryogenic pump has been designed at Argonne National Laboratory to circulate liquid nitrogen (LN2) in a closed circuit allowing the recovery of excess fluid. The pump can circulate LN2 at rates of 2-10 L/min, into a head of 0.5-3 m. Over four years of laboratory use the pump has proven capable of operating continuously for 50-100 days without maintenance.

  17. Designing the modern pump: engineering aspects of continuous subcutaneous insulin infusion software.

    PubMed

    Welsh, John B; Vargas, Steven; Williams, Gary; Moberg, Sheldon

    2010-06-01

    Insulin delivery systems attracted the efforts of biological, mechanical, electrical, and software engineers well before they were commercially viable. The introduction of the first commercial insulin pump in 1983 represents an enduring milestone in the history of diabetes management. Since then, pumps have become much more than motorized syringes and have assumed a central role in diabetes management by housing data on insulin delivery and glucose readings, assisting in bolus estimation, and interfacing smoothly with humans and compatible devices. Ensuring the integrity of the embedded software that controls these devices is critical to patient safety and regulatory compliance. As pumps and related devices evolve, software engineers will face challenges and opportunities in designing pumps that are safe, reliable, and feature-rich. The pumps and related systems must also satisfy end users, healthcare providers, and regulatory authorities. In particular, pumps that are combined with glucose sensors and appropriate algorithms will provide the basis for increasingly safe and precise automated insulin delivery-essential steps to developing a fully closed-loop system.

  18. Ultra-broadband infrared pump-probe spectroscopy using synchrotron radiation and a tuneable pump.

    PubMed

    Carroll, Lee; Friedli, Peter; Lerch, Philippe; Schneider, Jörg; Treyer, Daniel; Hunziker, Stephan; Stutz, Stefan; Sigg, Hans

    2011-06-01

    Synchrotron infrared sources have become popular mainly because of their excellent broadband brilliance, which enables spectroscopically resolved spatial-mapping of stationary objects at the diffraction limit. In this article we focus on an often-neglected further advantage of such sources - their unique time-structure - to bring such broadband spectroscopy to the time domain, for studying dynamic phenomenon down to the 100 ps limit. We describe the ultra-broadband (12.5 to 1.1 μm) Fourier transform pump-probe setup, for condensed matter transmission- and reflection-spectroscopy, installed at the X01DC infrared beam-line of the Swiss Light Source (SLS). The optical pump consists of a widely tuneable 100 ps 1 kHz laser system, covering 94% of the 16 to 1.1 μm range. A thorough description of the system is given, including (i) the vector-modulator providing purely electronic tuning of the pump-probe overlap up to 1 ms with sub-ps time resolution, (ii) the 500 MHz data acquisition system interfaced with the experimental physics and industrial control system (EPICS) based SLS control system for consecutive pulse sampling, and (iii) the step-scan time-slice Fourier transform scheme for simultaneous recording of the dual-channel pumped, un-pumped, and difference spectra. The typical signal/noise ratio of a single interferogram in a 100 ps time slice is 300 (measured during one single 140 s TopUp period). This signal/noise ratio is comparable to that of existing gated Globar pump-probe Fourier transform spectroscopy, but brings up to four orders of magnitude better time resolution. To showcase the utility of broadband pump-probe spectroscopy, we investigate a Ge-on-Si material system similar to that in which optically pumped direct-gap lasing was recently reported. We show that the mid-infrared reflection-spectra can be used to determine the optically injected carrier density, while the mid- and near-infrared transmission-spectra can be used to separate the strong pump

  19. Features of electric drive sucker rod pumps for oil production

    NASA Astrophysics Data System (ADS)

    Gizatullin, F. A.; Khakimyanov, M. I.; Khusainov, F. F.

    2018-01-01

    This article is about modes of operation of electric drives of downhole sucker rod pumps. Downhole oil production processes are very energy intensive. Oil fields contain many oil wells; many of them operate in inefficient modes with significant additional losses. Authors propose technical solutions to improve energy performance of a pump unit drives: counterweight balancing, reducing of electric motor power, replacing induction motors with permanent magnet motors, replacing balancer drives with chain drives, using of variable frequency drives.

  20. Another way of pumping blood with a rotary but noncentrifugal pump for an artificial heart.

    PubMed

    Monties, J R; Mesana, T; Havlik, P; Trinkl, J; Demunck, J L; Candelon, B

    1990-01-01

    This article describes an alternative mode of pumping blood inside the body. The device is a non centrifugal, valveless, low speed rotary pump, electrically powered, based on Wankel engine principle. The authors developed an implantable electrical actuator resulting in a compact, sealed motor-pump unit with electrical and magnetic components insulated from fluids. The results in the flow curve and in the pumping action show some common points but also some basic differences compared to classical pulsatile pumps or centrifugal pumps. The blood coming from the atrium follows a continuous movement without any stop flow but with variations creating pulsatility. Ejection and filling of the pump are simultaneous. It is always an active filling. Hydraulic efficiency depends on clearance in the pumping chamber and outlet port pressure. A 60 cc device allows flows up to 8-9 liters. The implantable motor is cyclindrical in shape, has a moderate weight (490 grams) and presents a good efficiency (32% for a rotary speed of 90 rpm against a mean aortic pressure of 150 mm of Hg). The authors conclude that their device could be proposed after further experimental studies, as an LVAD for shortterm assistance with a good promise for permanent application.