MIRANDA, EDWIN; OVERSTREET, BRITTANY S.; FOUNTAIN, WILLIAM A.; GUTIERREZ, VINCENT; KOLANKOWSKI, MICHAEL; OVERSTREET, MATTHEW L.; SAPP, RYAN M.; WOLFF, CHRISTOPHER A.; MAZZETTI, SCOTT A.
2017-01-01
To compare energy expenditure during and after active and handheld video game drumming compared to walking and sitting. Ten experienced, college-aged men performed four protocols (one per week): no-exercise seated control (CTRL), virtual drumming on a handheld gaming device (HANDHELD), active drumming on drum pads (DRUM), and walking on a treadmill at ~30% of VO2max (WALK). Protocols were performed after an overnight fast, and expired air was collected continuously during (30min) and after (30min) exercise. DRUM and HANDHELD song lists, day of the week, and time of day were identical for each participant. Significant differences (p < 0.05) among the average rates of energy expenditure (kcal·min−1) during activity included WALK > DRUM > HANDHELD. No significant differences in the rates of energy expenditure among groups during recovery were observed. Total energy expenditure was significantly greater (p < 0.05) during WALK (149.5 ± 30.6 kcal) compared to DRUM (118.7 ± 18.8 kcal) and HANDHELD (44.9±11.6 kcal), and greater during DRUM compared to HANDHELD. Total energy expenditure was not significantly different between HANDHELD (44.9 ± 11.6 kcal) and CTRL (38.2 ± 6.0 kcal). Active video game drumming at expert-level significantly increased energy expenditure compared to handheld, but it hardly met moderate-intensity activity standards, and energy expenditure was greatest during walking. Energy expenditure with handheld video game drumming was not different from no-exercise control. Thus, traditional aerobic exercise remains at the forefront for achieving the minimum amount and intensity of physical activity for health, individuals desiring to use video games for achieving weekly physical activity recommendations should choose games that require significant involvement of lower-body musculature, and time spent playing sedentary games should be a limited part of an active lifestyle. PMID:29170705
Miranda, Edwin; Overstreet, Brittany S; Fountain, William A; Gutierrez, Vincent; Kolankowski, Michael; Overstreet, Matthew L; Sapp, Ryan M; Wolff, Christopher A; Mazzetti, Scott A
2017-01-01
To compare energy expenditure during and after active and handheld video game drumming compared to walking and sitting. Ten experienced, college-aged men performed four protocols (one per week): no-exercise seated control (CTRL), virtual drumming on a handheld gaming device (HANDHELD), active drumming on drum pads (DRUM), and walking on a treadmill at ~30% of VO 2max (WALK). Protocols were performed after an overnight fast, and expired air was collected continuously during (30min) and after (30min) exercise. DRUM and HANDHELD song lists, day of the week, and time of day were identical for each participant. Significant differences (p < 0.05) among the average rates of energy expenditure (kcal·min -1 ) during activity included WALK > DRUM > HANDHELD. No significant differences in the rates of energy expenditure among groups during recovery were observed. Total energy expenditure was significantly greater (p < 0.05) during WALK (149.5 ± 30.6 kcal) compared to DRUM (118.7 ± 18.8 kcal) and HANDHELD (44.9±11.6 kcal), and greater during DRUM compared to HANDHELD. Total energy expenditure was not significantly different between HANDHELD (44.9 ± 11.6 kcal) and CTRL (38.2 ± 6.0 kcal). Active video game drumming at expert-level significantly increased energy expenditure compared to handheld, but it hardly met moderate-intensity activity standards, and energy expenditure was greatest during walking. Energy expenditure with handheld video game drumming was not different from no-exercise control. Thus, traditional aerobic exercise remains at the forefront for achieving the minimum amount and intensity of physical activity for health, individuals desiring to use video games for achieving weekly physical activity recommendations should choose games that require significant involvement of lower-body musculature, and time spent playing sedentary games should be a limited part of an active lifestyle.
Handheld Delivery System for Modified Boron-Type Fire Extinguishment Agent
1993-11-01
was to develop and test a handheld portable delivery system for use with the modified boron-type fire extinguishing agent for metal fires . B...BACKGROUND A need exists for an extinguishing agent and accompanying delivery system that are effective against complex geometry metal fires . A modified...agent and its delivery system have proven effective against complex geometry metal fires containing up to 200 pounds of magnesium metal. Further
NASA Astrophysics Data System (ADS)
Duran, Karolina-Petkovic; Zhu, Yonggang; Chen, Chuanpin; Swallow, Anthony; Stewart, Robert; Hoobin, Pam; Leech, Patrick; Ovenden, Simon
2008-12-01
This paper reports on the development of a hand-held device for on-site detection of organophosphonate nerve agent degradation products. This field-deployable analyzer relies on efficient microchip electrophoresis separation of alkyl methylphosphonic acids and their sensitive contactless conductivity detection. Miniaturized, low-powered design is coupled with promising analytical performance for separating the breakdown products of chemical warfare agents such as Soman, Sarin and VX . The detector has a detection limit of about 10 μg/mL and has a good linear response in the range 10-300 μg/mL concentration range. Applicability to environmental samples is demonstrated .The new hand-held analyzer offers great promise for converting conventional ion chromatography or capillary electrophoresis sophisticated systems into a portable forensic laboratory for faster, simpler and more reliable on-site screening.
Zhang, Yunfei; Liu, Haoran; Tang, Jiali; Li, Zhuoyun; Zhou, Xingyu; Zhang, Ren; Chen, Liang; Mao, Ying; Li, Cong
2017-05-31
A handheld Raman detector with operational convenience, high portability, and rapid acquisition rate has been applied in clinics for diagnostic purposes. However, the inherent weakness of Raman scattering and strong scattering of the turbid tissue restricts its utilization to superficial locations. To extend the applications of a handheld Raman detector to deep tissues, a gold nanostar-based surface-enhanced Raman scattering (SERS) nanoprobe with robust colloidal stability, a fingerprint-like spectrum, and extremely high sensitivity (5.0 fM) was developed. With the assistance of FPT, a multicomponent optical clearing agent (OCA) efficiently suppressing light scattering from the turbid dermal tissues, the handheld Raman detector noninvasively visualized the subcutaneous tumor xenograft with a high target-to-background ratio after intravenous injection of the gold nanostar-based SERS nanoprobe. To the best of our knowledge, this work is the first example to introduce the optical clearing technique in assisting SERS imaging in vivo. The combination of optical clearing technology and SERS is a promising strategy for the extension of the clinical applications of the handheld Raman detector from superficial tissues to subcutaneous or even deeper lesions that are usually "concealed" by the turbid dermal tissue.
Elbow joint position sense after neuromuscular training with handheld vibration.
Tripp, Brady L; Faust, Donald; Jacobs, Patrick
2009-01-01
Clinicians use neuromuscular control exercises to enhance joint position sense (JPS); however, because standardizing such exercises is difficult, validations of their use are limited. To evaluate the acute effects of a neuromuscular training exercise with a handheld vibrating dumbbell on elbow JPS acuity. Crossover study. University athletic training research laboratory. Thirty-one healthy, college-aged volunteers (16 men, 15 women, age = 23 + or - 3 years, height = 173 + or - 8 cm, mass = 76 + or - 14 kg). We measured and trained elbow JPS using an electromagnetic tracking device that provided auditory and visual biofeedback. For JPS testing, participants held a dumbbell and actively identified the target elbow flexion angle (90 degrees ) using the software-generated biofeedback, followed by 3 repositioning trials without feedback. Each neuromuscular training protocol included 3 exercises during which participants held a 2.55-kg dumbbell vibrating at 15, 5, or 0 Hz and used software-generated biofeedback to locate and maintain the target elbow flexion angle for 15 seconds. We calculated absolute (accuracy) and variable (variability) errors using the differences between target and reproduced angles. Training protocols using 15-Hz vibration enhanced accuracy and decreased variability of elbow JPS (P < or = .005), whereas 5-Hz vibration did not affect accuracy (F(1,61) = 2.625, P = .100) but did decrease variability (F(1,61) = 7.250, P = .009). The control condition and 0-Hz training protocol had no effect on accuracy or variability (P > or = .200). Our results suggest these neuromuscular control exercises, which included low-magnitude, low-frequency handheld vibration, may enhance elbow JPS. Future researchers should examine vibration of various durations and frequencies, should include injured participants and functional multijoint and multiplanar measures, and should examine long-term effects of training protocols on JPS and injury.
Influence of light source, polarization, education, and training on shade matching quality.
Clary, Jacqueline A; Ontiveros, Joe C; Cron, Stanley G; Paravina, Rade D
2016-07-01
Many factors influence the quality of shade selection, and isolating how significantly each of these factors influences results is difficult. The purpose of this in vitro study was to compare results of shade matching using handheld lights with or without a polarizing filter with results obtained using a professional viewing booth and to analyze the influence of education and training on shade selection outcome. A total of 96 third-year dental students (evaluators) were randomly separated into 4 groups. Each group was assigned 1 of 2 handheld shade-matching devices (lights) with or without a polarizing filter. Each group performed a shade matching exercise using the handheld light or a professional viewing booth. The exercise consisted of matching shade tabs placed in a typodont to a commercial shade guide. Each group repeated this procedure 4 times over a 9-week period. A lecture on shade matching was presented at the fifth week of the study, between "before" and "after" shade matching procedures. Shade matching scores with handheld lights (7.8) were higher than scores of shade matching with the viewing booth (7.2). The mean scores for before (7.2) and after (7.8) shade matching (with education and training in between) were significantly different. The combined effect of light and education and training improved the shade matching score by 1.2, from 6.8 in the before sessions using the viewing booth to 8.0 in the after sessions using handheld lights. A 21% increase in the number of evaluators who selected 1 of 4 best matches was recorded, 10% for handheld lights versus viewing booth after education and training versus before sessions and 11% between after sessions using handheld lights versus before sessions using viewing booth. Within the limits of the study, the shade matching scores with handheld lights were significantly better than the results obtained using a viewing booth (P<.01). Using a handheld light with or without a polarizing filter did not influence shade matching results. Mean shade matching scores were significantly better after education and training (P<.01). Light combined with education and training resulted in the greatest increase in shade matching quality. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Webster, Harry
2002-08-01
One or more Halon 1211 hand-held fire extinguishers are specified in Federal Aviation Regulation (FAR) Part 25.851 as a requirement on transport category aircraft with 31 or more seats. Halon 1211 has been linked to the destruction of the ozone layer and production of new Halon 1211 has been halted per the Montreal Protocol in 1993. The phase out of Halon 1211, as the hand-held firefighting agent of choice, for civilian transport category aircraft has necessitated the development of a Minimum Performance Standard (MPS) to evaluate replacement agents. The purpose of the MPS is to insure that there is no reduction in safety, both in terms of effectiveness in fighting onboard fires and toxicity to the passengers and crew. The MPS specifies two new tests that replacement agents must pass in addition to requiring national certifications such as provided by Underwriters Laboratories. The first test evaluates the "flooding" characteristics of the agent against a hidden in-flight fire. This test determines the ability of a streaming agent to function as a flooding agent. The second test evaluates the performance of the agent in fighting a terrorist fire scenario and the associated toxicity hazard. This test measures the agent's ability to extinguish a triple-seat fire in an aircraft cabin under in-flight conditions and the toxicity characteristics of both the neat agent and the products of decomposition. This MPS will insure that the replacement agents will meet or exceed the performance of Halon 1211 both in fighting fires and maintaining a safe breathing environment in aircraft cabins.
Handheld Fluorescence Resonance Energy Transfer (FRET)-Aptamer Sensor for Bone Markers
NASA Technical Reports Server (NTRS)
Bruno, John G.
2015-01-01
Astronauts lose significant bone mass during lengthy space flights. NASA wishes to monitor this bone loss in order to develop nutritional and exercise countermeasures. Operational Technologies Corporation (OpTech) has developed a handheld device that quantifies bone loss in a spacecraft environment. The innovation works by adding fluorescent dyes and quenchers to aptamers to enable pushbutton, one-step bind-and-detect FRET assays that can be freeze-dried, rehydrated with body fluids, and used to quantify bone loss.
Developing Secure Agent Systems Using Delegation Based Trust Management
2005-01-01
delegation rules, so that the information in the SCM may be accessed only by authorized agents. Special intelligent agents called security agents are re... Bluetooth , IEEE 802.11, or Infrared, via any hand-held device, within a Vigil can also be used in wired systems, but the focal point of our re- search is
Elbow Joint Position Sense After Neuromuscular Training With Handheld Vibration
Tripp, Brady L.; Faust, Donald; Jacobs, Patrick
2009-01-01
Abstract Context: Clinicians use neuromuscular control exercises to enhance joint position sense (JPS); however, because standardizing such exercises is difficult, validations of their use are limited. Objective: To evaluate the acute effects of a neuromuscular training exercise with a handheld vibrating dumbbell on elbow JPS acuity. Design: Crossover study. Setting: University athletic training research laboratory. Patients or Other Participants: Thirty-one healthy, college-aged volunteers (16 men, 15 women, age = 23 ± 3 years, height = 173 ± 8 cm, mass = 76 ± 14 kg). Intervention(s): We measured and trained elbow JPS using an electromagnetic tracking device that provided auditory and visual biofeedback. For JPS testing, participants held a dumbbell and actively identified the target elbow flexion angle (90°) using the software-generated biofeedback, followed by 3 repositioning trials without feedback. Each neuromuscular training protocol included 3 exercises during which participants held a 2.55-kg dumbbell vibrating at 15, 5, or 0 Hz and used software-generated biofeedback to locate and maintain the target elbow flexion angle for 15 seconds. Main Outcome Measure(s): We calculated absolute (accuracy) and variable (variability) errors using the differences between target and reproduced angles. Results: Training protocols using 15-Hz vibration enhanced accuracy and decreased variability of elbow JPS (P ≤ .005), whereas 5-Hz vibration did not affect accuracy (F1,61 = 2.625, P = .100) but did decrease variability (F1,61 = 7.250, P = .009). The control condition and 0-Hz training protocol had no effect on accuracy or variability (P ≥ .200). Conclusions: Our results suggest these neuromuscular control exercises, which included low-magnitude, low-frequency handheld vibration, may enhance elbow JPS. Future researchers should examine vibration of various durations and frequencies, should include injured participants and functional multijoint and multiplanar measures, and should examine long-term effects of training protocols on JPS and injury. PMID:19911088
Data for Users of Handheld Ion Mobility Spectrometers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keith A. Daum; Sandra L. Fox
Chemical detection technology end-user surveys conducted by Idaho National Laboratory (INL) in 2005 and 2007 indicated that first responders believed manufacturers’ claims for instruments sometimes were not supported in field applications, and instruments sometimes did not meet their actual needs. Based on these findings, the Department of Homeland Security (DHS) asked INL to conduct a similar survey for handheld ion mobility spectrometers (IMS), which are used by a broad community of first responders as well as for other applications. To better access this broad community, the INL used the Center for Technology Commercialization, Inc. (CTC), Public Safety Technology Center (PSTC)more » to set up an online framework to gather information from users of handheld IMS units. This framework (Survey Monkey) was then used to perform an online Internet survey, augmented by e-mail prompts, to get information from first responders and personnel from various agencies about their direct experience with handheld IMS units. Overall, 478 individuals responded to the survey. Of these, 174 respondents actually owned a handheld IMS. Performance and satisfaction data from these 174 respondents are captured in this report. The survey identified the following observations: • The most common IMS unit used by respondents was the Advanced Portable Detector (APD 2000), followed by ChemRae, Sabre 4000, Sabre 2000, Draeger Multi IMS, Chemical Agent Monitor-2, Chemical Agent Monitor, Vapor Tracer, and Vapor Tracer 2. • The primary owners were HazMat teams (20%), fire services (14%), local police (12%), and sheriffs’ departments (9%). • IMS units are seldom used as part of an integrated system for detecting and identifying chemicals but instead are used independently. • Respondents are generally confused about the capabilities of their IMS unit. This is probably a result of lack of training. • Respondents who had no training or fewer than 8 hours were not satisfied with the overall operation of the handheld IMS unit. • IMS units were used for detecting a range of analytes. The most common use was for detection of hazardous chemicals, followed by detection of explosives, illicit drugs, chemical warfare, nerve agents, and radiation. One IMS unit had dual capability as a radiation detector. • Respondents who did not own an IMS listed prohibitive cost of equipment as the main factor for not having one. • Respondents who were highly satisfied with the overall operation of the handheld IMS obtained the IMS through a direct purchase. In comparison, the respondents who were not satisfied had obtained the handheld IMS through a DHS grant.« less
Detection of munitions grade g-series nerve agents using Raman excitation at 1064 nm
NASA Astrophysics Data System (ADS)
Roy, Eric; Wilcox, Phillip G.; Hoffland, Soren; Pardoe, Ian
2015-05-01
Raman spectroscopy is a powerful tool for obtaining molecular structure information of a sample. While Raman spectroscopy is a common laboratory based analytical tool, miniaturization of opto-electronic components has allowed handheld Raman analyzers to become commercially available. These handheld systems are utilized by Military and First Responder operators tasked with rapidly identifying potentially hazardous chemicals in the field. However, one limitation of many handheld Raman detection systems is strong interference caused by fluorescence of the sample or underlying surface which obscures the characteristic Raman signature of the target analyte. Munitions grade chemical warfare agents (CWAs) are produced and stored in large batches and typically have more impurities from the storage container, degradation, or unreacted precursors. In this work, Raman spectra of munitions grade CWAs were collected using a handheld Raman spectrometer with a 1064 nm excitation laser. While Raman scattering generated by a 1064 nm laser is inherently less efficient than excitation at shorter wavelengths, high quality spectra were easily obtained due to significantly reduced fluorescence of the munitions grade CWAs. The spectra of these less pure, but more operationally relevant, munitions grade CWAs were then compared to spectra of CASARM grade CWAs, as well as Raman spectra collected using the more common 785 nm excitation laser.
Hand-Held Devices Detect Explosives and Chemical Agents
NASA Technical Reports Server (NTRS)
2010-01-01
Ion Applications Inc., of West Palm Beach, Florida, partnered with Ames Research Center through Small Business Innovation Research (SBIR) agreements to develop a miniature version ion mobility spectrometer (IMS). While NASA was interested in the instrument for detecting chemicals during exploration of distant planets, moons, and comets, the company has incorporated the technology into a commercial hand-held IMS device for use by the military and other public safety organizations. Capable of detecting and identifying molecules with part-per-billion sensitivity, the technology now provides soldiers with portable explosives and chemical warfare agent detection. The device is also being adapted for detecting drugs and is employed in industrial processes such as semiconductor manufacturing.
Using GPS To Teach More Than Accurate Positions.
ERIC Educational Resources Information Center
Johnson, Marie C.; Guth, Peter L.
2002-01-01
Undergraduate science majors need practice in critical thinking, quantitative analysis, and judging whether their calculated answers are physically reasonable. Develops exercises using handheld Global Positioning System (GPS) receivers. Reinforces students' abilities to think quantitatively, make realistic "back of the envelope"…
Studying Reliability Using Identical Handheld Lactate Analyzers
ERIC Educational Resources Information Center
Stewart, Mark T.; Stavrianeas, Stasinos
2008-01-01
Accusport analyzers were used to generate lactate performance curves in an investigative laboratory activity emphasizing the importance of reliable instrumentation. Both the calibration and testing phases of the exercise provided students with a hands-on opportunity to use laboratory-grade instrumentation while allowing for meaningful connections…
Enzymatic test kits, generally designed to be handheld and portable, detect the presence of chemical agents, carbamate pesticides, and/or organophosphate pesticides by relying on the reaction of the cholinesterase enzyme. Under normal conditions, the enzyme reacts as expected wi...
Sarkar, Archana; Dutta, Arup; Dhingra, Usha; Dhingra, Pratibha; Verma, Priti; Juyal, Rakesh; Black, Robert E; Menon, Venugopal P; Kumar, Jitendra; Sazawal, Sunil
2006-08-01
In settings in developing countries, children often socialize with multiple socializing agents (peers, siblings, neighbors) apart from their parents, and thus, a measurement of a child's social interactions should be expanded beyond parental interactions. Since the environment plays a role in shaping a child's development, the measurement of child-socializing agents' interactions is important. We developed and used a computerized observational software Behavior and Social Interaction Software (BASIS) with a preloaded coding scheme installed on a handheld Palm device to record complex observations of interactions between children and socializing agents. Using BASIS, social interaction assessments were conducted on 573 preschool children for 1 h in their natural settings. Multiple screens with a set of choices in each screen were designed that included the child's location, broad activity, state, and interactions with child-socializing agents. Data were downloaded onto a computer and systematically analyzed. BASIS, installed on Palm OS (M-125), enabled the recording of the complex interactions of child-socializing agents that could not be recorded with manual forms. Thus, this tool provides an innovative and relatively accurate method for the systematic recording of social interactions in an unrestricted environment.
Students' Framing of Laboratory Exercises Using Infrared Cameras
ERIC Educational Resources Information Center
Haglund, Jesper; Jeppsson, Fredrik; Hedberg, David; Schönborn, Konrad J.
2015-01-01
Thermal science is challenging for students due to its largely imperceptible nature. Handheld infrared cameras offer a pedagogical opportunity for students to see otherwise invisible thermal phenomena. In the present study, a class of upper secondary technology students (N = 30) partook in four IR-camera laboratory activities, designed around the…
Johnson, Miriam J; Booth, Sara; Currow, David C; Lam, Lawrence T; Phillips, Jane L
2016-05-01
The handheld fan is an inexpensive and safe way to provide facial airflow, which may reduce the sensation of chronic refractory breathlessness, a frequently encountered symptom. To test the feasibility of developing an adequately powered, multicenter, multinational randomized controlled trial comparing the efficacy of a handheld fan and exercise advice with advice alone in increasing activity in people with chronic refractory breathlessness from a variety of medical conditions, measuring recruitment rates; data quality; and potential primary outcome measures. This was a Phase II, multisite, international, parallel, nonblinded, mixed-methods randomized controlled trial. Participants were centrally randomized to fan or control. All received breathlessness self-management/exercise advice and were followed up weekly for four weeks. Participants/carers were invited to participate in a semistructured interview at the study's conclusion. Ninety-seven people were screened, 49 randomized (mean age 68 years; 49% men), and 43 completed the study. Site recruitment varied from 0.25 to 3.3/month and screening:randomization from 1.1:1 to 8.5:1. There were few missing data except for the Chronic Obstructive Pulmonary Disease Self-Efficacy Scale (two-thirds of data missing). No harms were observed. Three interview themes included 1) a fan is a helpful self-management strategy, 2) a fan aids recovery, and 3) a symptom control trial was welcome. A definitive, multisite trial to study the use of the handheld fan as part of self-management of chronic refractory breathlessness is feasible. Participants found the fan useful. However, the value of information for changing practice or policy is unlikely to justify the expense of such a trial, given perceived benefits, the minimal costs, and an absence of harms demonstrated in this study. Copyright © 2016 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
Jump Training in Youth Soccer Players: Effects of Haltere Type Handheld Loading.
Rosas, F; Ramirez-Campillo, R; Diaz, D; Abad-Colil, F; Martinez-Salazar, C; Caniuqueo, A; Cañas-Jamet, R; Loturco, I; Nakamura, F Y; McKenzie, C; Gonzalez-Rivera, J; Sanchez-Sanchez, J; Izquierdo, M
2016-12-01
The aim of this study was to compare the effects of a jump training program, with or without haltere type handheld loading, on maximal intensity exercise performance. Youth soccer players (12.1±2.2 y) were assigned to either a jump training group (JG, n=21), a jump training group plus haltere type handheld loading (LJG, n=21), or a control group following only soccer training (CG, n=21). Athletes were evaluated for maximal-intensity performance measures before and after 6 weeks of training, during an in-season training period. The CG achieved a significant change in maximal kicking velocity only (ES=0.11-0.20). Both jump training groups improved in right leg (ES=0.28-0.45) and left leg horizontal countermovement jump with arms (ES=0.32-0.47), horizontal countermovement jump with arms (ES=0.28-0.37), vertical countermovement jump with arms (ES=0.26), 20-cm drop jump reactive strength index (ES=0.20-0.37), and maximal kicking velocity (ES=0.27-0.34). Nevertheless, compared to the CG, only the LJG exhibited greater improvements in all performance tests. Therefore, haltere type handheld loading further enhances performance adaptations during jump training in youth soccer players. © Georg Thieme Verlag KG Stuttgart · New York.
Language Centres: Are We Holding the Future in Our Hands?
ERIC Educational Resources Information Center
Robinson, Ian Michael
2018-01-01
With the advent of web 2.0 and the ease of use of many hand-held devices, access to the internet has never been easier. This has been accompanied by a growing range of sites available for learning an L2. These sites offer lessons, explanations, exercises, corrections and feedback. It now becomes time once again to question whether physical bricks…
Differential mobility spectroscopy for chemical agent detection
NASA Astrophysics Data System (ADS)
Griffin, M. Todd
2006-05-01
General Dynamics ATP (GDATP) and Sionex Corporation (Sionex) are carrying out a cooperative development for a handheld chemical agent detector, being called JUNO TM, which will have lower false positives, higher sensitivity, and improved interference rejection compared with presently available detectors. This enhanced performance is made possible by the use of a new principle of ion separation called Differential Mobility Spectrometry (DMS). The enhanced selectivity is provided by the field tunable nature of the Sionex differential mobility technology (microDMxTM) which forms the analytical heart of the JUNO system and enables fingerprinting of molecules by characterization of the ionized molecular behavior under multiple electric field conditions. This enhanced selectivity is valuable in addressing not only the traditional list of chemical warfare agents (CWA) but also the substantial list of Toxic Industrial Compounds (TICs) and Toxic Industrial Materials (TIMs) which may be released in warfare or terrorist situations. Experimental results showing the ability of the microDMx to reject interferences, detect and resolve live agents are presented. An additional breakthrough in the technology was realized by operating the device at a reduced pressure of around 0.5 atmospheres. This reduced pressure operation resulted in roughly doubling the spectrometers resolution over what has previously been reported [1]. Advances have also been made in power consumption and packaging leading to a device suitable for portable, handheld, applications. Experimental results illustrating the performance of the microDMx technology employed in JUNO are highlighted.
Study of Fire Extinguishment of a Replacement Fluid for Use in Transformers in Lieu of Askarel
DOT National Transportation Integrated Search
1981-04-01
A series of tests were performed at the Factory Mutual Test Center 1) to obtain information on the performance of various extinguishing agents used with hand-held fire extinguishers to control fire involving a Midel,a transformer fluid for replacem...
MicroChemLab, A Novel Approach for Handheld Chemical Sensing
NASA Astrophysics Data System (ADS)
Lewis, Patrick
2003-03-01
In 1996, Sandia National Laboratories began development of a chemical sensing platform based on microfabricated components. The goal of the project was to develop a handheld system for the detection of chemical warfare (CW) agent vapors in air. The components developed for this project are analogous to devices used in analytical laboratories. The benefit of microfabrication is that the resulting components are small and require little power to operate. The key elements of MicroChemLab are a sample collector - preconcentrator, a GC column and a surface acoustic wave (SAW) array detector. The preconcentrator is a thermally isolated silicon nitride membrane with a resistive heater patterned on one side and a sorptive sol gel film deposited on the other. Since the membrane has a very small mass, the resistive heater can ballistically elevate the temperature of the sorptive film to 200° C in approximately 10 ms. The sol gel film collects target compounds efficiently, but rejects volatile industrial solvents like alcohols, ketones, etc. The GC column is a one-meter high aspect ratio spiral channel etched in silicon with an anodically bonded pyrex lid completing the channel. A heater patterned on the silicon allows the column to be temperature ramped. Analytes injected from the preconcentrator are separated in this stage. The SAW array detector contains 3 delay lines used for sensing and 1 reference delay line. Each delay line is driven by an application specific integrated circuit (ASIC) at 500 MHz. Instead of counting frequency, additional ASICs incorporate a phase comparator that delivers a DC signal proportional to the amount of phase change. The three sensing elements of the detector provide a pattern that is indicative of the class of compound detected i.e. nerve agents or blister agents. Combined, these components provide a selective and sensitive handheld solution for the detection of chemical warfare agents. We will present lab data showing the performance of individual components and field data demonstrating the performance of this system. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under Contract DE-AC04-94AL85000.
Hyperspectral Imagery for Large Area Survey of Organophosphate Pesticides
2015-03-26
possible (Simonian et al., 2004). Nanotechnology has the potential for the development of handheld, real-time, and accurate OP detectors ( Goltz et...dx.doi.org.wrs.idm.oclc.org/10.1016/j.talanta.2012.10.016 Goltz , Mark, N.Dong Shik, Kim, Racz, LeeAnn. (2011). Using nanotechnology to detect nerve agents. Air & Space
NASA Astrophysics Data System (ADS)
Wolf, Jan-Christoph; Etter, Raphael; Schaer, Martin; Siegenthaler, Peter; Zenobi, Renato
2016-07-01
An active capillary plasma ionization (ACI) source was coupled to a handheld mass spectrometer (Mini 10.5; Aston Labs, West Lafayette, IN, USA) and applied to the direct gas-phase detection and quantification of chemical warfare agent (CWA) related chemicals. Complementing the discontinuous atmospheric pressure interface (DAPI) of the Mini 10.5 mass spectrometer with an additional membrane pump, a quasi-continuous sample introduction through the ACI source was achieved. Nerve agent simulants (three dialkyl alkylphosphonates, a dialkyl phosporamidate, and the pesticide dichlorvos) were detected at low gas-phase concentrations with limits of detection ranging from 1.0 μg/m3 to 6.3 μg/m3. Our results demonstrate a sensitivity enhancement for portable MS-instrumentation by using an ACI source, enabling direct, quantitative measurements of volatile organic compounds. Due to its high sensitivity, selectivity, low power consumption (<80 W) and weight (<13 kg), this instrumentation has the potential for direct on-site CWA detection as required by military or civil protection.
An Active Learning Exercise for Introducing Agent-Based Modeling
ERIC Educational Resources Information Center
Pinder, Jonathan P.
2013-01-01
Recent developments in agent-based modeling as a method of systems analysis and optimization indicate that students in business analytics need an introduction to the terminology, concepts, and framework of agent-based modeling. This article presents an active learning exercise for MBA students in business analytics that demonstrates agent-based…
Erickson, Melissa L; Little, Jonathan P; Gay, Jennifer L; McCully, Kevin K; Jenkins, Nathan T
2017-04-01
Type 2 diabetes treatment primarily focuses on reducing hyperglycemia, including postprandial glucose excursions. Hypoglycemic agents are used clinically to lower fasting and postprandial glucose. Metformin is the first-line therapy; however, if metformin is inadequate then 'add-on' hypoglycemic agents are implemented. Postmeal exercise has been shown to lower postprandial glucose. The aim of this study was to assess if postmeal exercise provides additional glucose-lowering benefit, beyond medication alone, in those on add-on hypoglycemic agents. Postprandial glucose excursions in eight participants with type 2 diabetes (Age: 60±10.7, HbA 1C : 7.9±2.3) being treated with add-on hypoglycemic agents were assessed during both drug-treated sedentary and drug-treated postmeal exercise conditions. Continuous glucose monitoring was used to assess peak and area under the glucose curve (AUC) during exercise, as well as peak within a 2-h time window, 2-h total and 2-h incremental AUC after a standardized breakfast meal. Postmeal exercise consisted of 3×10-min intervals of treadmill walking at 50% maximal oxygen uptake. Glucose peak (drug only: 13.8±3.7, drug/exercise: 9.9±2.7mmol/L; p=0.02) and AUC (drug only: 500±136, drug/exercise: 357±89mmol/L×40min; p=0.03) were reduced during postmeal exercise. Breakfast 2-h incremental AUC was also reduced (drug only: 585±291, drug/exercise: 330±294; p=0.047). Post-breakfast exercise lowered glucose during the exercise bout, although this effect was not sustained on later meals. Copyright © 2017 Elsevier B.V. All rights reserved.
Supervised Versus Home Exercise Training Programs on Functional Balance in Older Subjects.
Youssef, Enas Fawzy; Shanb, Alsayed Abd Elhameed
2016-11-01
Aging is associated with a progressive decline in physical capabilities and a disturbance of both postural control and daily living activities. The aim of this study was to evaluate the effects of supervised versus home exercise programs on muscle strength, balance and functional activities in older participants. Forty older participants were equally assigned to a supervised exercise program (group-I) or a home exercise program (group-II). Each participant performed the exercise program for 35-45 minutes, two times per week for four months. Balance indices and isometric muscle strength were measured with the Biodex Balance System and Hand-Held Dynamometer. Functional activities were evaluated by the Berg Balance Scale (BBS) and the timed get-up-and-go test (TUG). The mean values of the Biodex balance indices and the BBS improved significantly after both the supervised and home exercise programs ( P < 0.05). However, the mean values of the TUG and muscle strength at the ankle, knee and hip improved significantly only after the supervised program. A comparison between the supervised and home exercise programs revealed there were only significant differences in the BBS, TUG and muscle strength. Both the supervised and home exercise training programs significantly increased balance performance. The supervised program was superior to the home program in restoring functional activities and isometric muscle strength in older participants.
Scrivener, Katharine; Sherrington, Catherine; Schurr, Karl; Treacy, Daniel
2011-01-01
Are inpatients undergoing rehabilitation who appear able to count exercises able to quantify accurately the amount of exercise they undertake? Observational study. Inpatients in an aged care rehabilitation unit and a neurological rehabilitation unit, who appeared able to count their exercises during a 1-2 min observation by their treating physiotherapist. Participants were observed for 30 min by an external observer while they exercised in the physiotherapy gymnasium. Both the participants and the observer counted exercise repetitions with a hand-held tally counter and the two tallies were compared. Of the 60 people admitted for aged care rehabilitation during the study period, 49 (82%) were judged by their treating therapist to be able to count their own exercise repetitions accurately. Of the 30 people admitted for neurological rehabilitation during the study period, 20 (67%) were judged by their treating therapist to be able to count their repetitions accurately. Of the 69 people judged to be accurate, 40 underwent observation while exercising. There was excellent agreement between these participants' counts of their exercise repetitions and the observers' counts, ICC (3,1) of 0.99 (95% CI 0.98 to 0.99). Eleven participants (28%) were in complete agreement with the observer. A further 19 participants (48%) varied from the observer by less than 10%. Therapists were able to identify a group of rehabilitation participants who were accurate in counting their exercise repetitions. Counting of exercise repetitions by therapist-selected patients is a valid means of quantifying exercise dosage during inpatient rehabilitation. Copyright © 2011 Australian Physiotherapy Association. Published by .. All rights reserved.
Implementation of a new technology for point detection
NASA Astrophysics Data System (ADS)
Petinarides, John; Griffin, M. Todd; Miller, Ranaan A.; Nazarov, Erkinjon G.; Bashall, Anthony D.
2005-05-01
General Dynamics ATP (GDATP) and Sionex Corporation (Sionex) are carrying out a cooperative development for a handheld chemical agent detector, being called JUNO, which will have lower false positives, higher sensitivity, and improved interference rejection compared with presently available detectors. This enhanced performance is made possible by the use of a new principle of ion separation called Differential Mobility Spectrometry (DMS). The enhanced selectivity is provided by the field tunable nature of the Sionex differential mobility technology (microDMxTM) which forms the analytical heart of the JUNO system and enables fingerprinting of molecules by characterization of the ionized molecular behavior under multiple electric field conditions. This enhanced selectivity is valuable in addressing not only the traditional list of chemical warfare agents (CWA) but also the substantial list of Toxic Industrial Compounds (TICs) and Toxic Industrial Materials (TIMs) which may be released in warfare or terrorist situations. Experimental results showing the ability of the microDMx to reject interferences, detect and resolve live agents are presented. An additional breakthrough in the technology was realized by operating the device at a reduced pressure of around 0.5 atmospheres. This reduced pressure operation resulted in roughly doubling the spectrometers resolution over what has previously been reported [1]. Advances have also been made in power consumption and packaging leading to a device suitable for portable, handheld, applications. Experimental results illustrating the performance of the microDMx technology employed in JUNO are highlighted.
2012-06-01
Reference values of maximum isometric muscle force obtained in 270 children aged 4-16 years by hand-held dynamometry. Neuromuscul Disord. 2001;11(5...evaluation of specific muscle groups responsible for fatigue-related changes. Since fiber type proportion is determined by its innervation, evaluating muscle ... fiber output provides down-stream information about the integrity of the motor neuron. Objective To determine the association between muscle
Social Cognitive Theory Predictors of Exercise Behavior in Endometrial Cancer Survivors
Basen-Engquist, Karen; Carmack, Cindy L.; Li, Yisheng; Brown, Jubilee; Jhingran, Anuja; Hughes, Daniel C.; Perkins, Heidi Y.; Scruggs, Stacie; Harrison, Carol; Baum, George; Bodurka, Diane C.; Waters, Andrew
2014-01-01
Objective This study evaluated whether social cognitive theory (SCT) variables, as measured by questionnaire and ecological momentary assessment (EMA), predicted exercise in endometrial cancer survivors. Methods One hundred post-treatment endometrial cancer survivors received a 6-month home-based exercise intervention. EMAs were conducted using hand-held computers for 10- to 12-day periods every 2 months. Participants rated morning self-efficacy and positive and negative outcome expectations using the computer, recorded exercise information in real time and at night, and wore accelerometers. At the midpoint of each assessment period participants completed SCT questionnaires. Using linear mixed-effects models, we tested whether morning SCT variables predicted minutes of exercise that day (Question 1) and whether exercise minutes at time point Tj could be predicted by questionnaire measures of SCT variables from time point Tj-1 (Question 2). Results Morning self-efficacy significantly predicted that day’s exercise minutes (p<.0001). Morning positive outcome expectations was also associated with exercise minutes (p=0.0003), but the relationship was attenuated when self-efficacy was included in the model (p=0.4032). Morning negative outcome expectations was not associated with exercise minutes. Of the questionnaire measures of SCT variables, only exercise self-efficacy predicted exercise at the next time point (p=0.003). Conclusions The consistency of the relationship between self-efficacy and exercise minutes over short (same day) and longer (Tj to Tj-1) time periods provides support for a causal relationship. The strength of the relationship between morning self-efficacy and exercise minutes suggest that real-time interventions that target daily variation in self-efficacy may benefit endometrial cancer survivors’ exercise adherence. PMID:23437853
Siriphorn, Akkradate; Chamonchant, Dannaovarat
2015-01-01
[Purpose] The potential health benefits of the Nintendo Wii balance board exercise have been widely investigated. However, no study has been conducted to examine the benefits of Wii exercise for overweight young adults. The aim of this study was to investigate the effect of exercise performed on a Nintendo Wii balance board on the balance and lower limb muscle strength in overweight young adults. [Subjects and Methods] Within-subject repeated measures analysis was used. Sixteen young adults (aged 21.87±1.13 years, body mass index 24.15 ± 0.50 kg/m(2)) were recruited. All subjects performed an exercise program on a Wii balance board for 8 weeks (30 min/session, twice a week for 8 weeks). A NeuroCom Balance Master and a hand-held dynamometer were used to measure balance performance and lower limb muscle strength. [Results] According to the comparison of pre- and post-intervention measurements, the Wii balance board exercise program significantly improved the limit of stability parameters. There was also a significant increase in strength of four lower-limb muscle groups: the hip flexor, knee flexor, ankle dorsiflexor and ankle plantarflexor. [Conclusion] These findings suggest that a Wii balance board exercise program can be used to improve the balance and lower limb muscle strength of overweight young adults.
Wireless remote monitoring of myocardial ischemia using reconstructed 12-lead ECGs.
Vukcevic, Vladan; Panescu, Dorin; Bojovic, Bosko; George, Samuel; Gussak, Ihor; Giga, Vojislav; Stankovic, Ivana
2010-01-01
CardioBip (CB) is a hand-held patient-activated device for recording and wireless transmission of reconstructed 12-lead ECG (12CB) based on patient specific matrices. It has 5 contact points: 3 precordial and 2 on the device top serving as limb leads when touched by index fingers. To determine whether CB could be used to monitor coronary disease (CAD) patients, we compared 12CB to simultaneous 12-lead ECGs (12L) in patients with CAD, pre-and post-exercise treadmill testing (ETT). The study goals were to assess: (1) whether 12CB can accurately reconstruct and wirelessly transmit 12-lead ECGs in CAD patients during ETT recovery; (2) whether 12CB can be used to evaluate ST segment changes in patients with exercise-induced ischemia.
NASA Astrophysics Data System (ADS)
Gomer, Nathaniel R.; Gardner, Charles W.; Nelson, Matthew P.
2016-05-01
Hyperspectral imaging (HSI) is a valuable tool for the investigation and analysis of targets in complex background with a high degree of autonomy. HSI is beneficial for the detection of threat materials on environmental surfaces, where the concentration of the target of interest is often very low and is typically found within complex scenery. Two HSI techniques that have proven to be valuable are Raman and shortwave infrared (SWIR) HSI. Unfortunately, current generation HSI systems have numerous size, weight, and power (SWaP) limitations that make their potential integration onto a handheld or field portable platform difficult. The systems that are field-portable do so by sacrificing system performance, typically by providing an inefficient area search rate, requiring close proximity to the target for screening, and/or eliminating the potential to conduct real-time measurements. To address these shortcomings, ChemImage Sensor Systems (CISS) is developing a variety of wide-field hyperspectral imaging systems. Raman HSI sensors are being developed to overcome two obstacles present in standard Raman detection systems: slow area search rate (due to small laser spot sizes) and lack of eye-safety. SWIR HSI sensors have been integrated into mobile, robot based platforms and handheld variants for the detection of explosives and chemical warfare agents (CWAs). In addition, the fusion of these two technologies into a single system has shown the feasibility of using both techniques concurrently to provide higher probability of detection and lower false alarm rates. This paper will provide background on Raman and SWIR HSI, discuss the applications for these techniques, and provide an overview of novel CISS HSI sensors focused on sensor design and detection results.
2010-11-01
minced finely with scissors, and transferred to a pre-cooled hand-held glass dounce homogenizer. The pestle was passed through the dounce until the...Nakajima, Sarin experiences in Japan : acute toxicity and long-term effects. Journal of the Neurological Sciences, 2006. 249(1): p. 76-85. 9. Shih, T.-M
Kusumoto, Yasuaki; Nitta, Osamu; Takaki, Kenji
2016-10-01
In the present study, we aimed to determine whether similarly loaded sit-to-stand exercises at different speeds improve the physiological cost of walking in children with spastic diplegia. This design was a single-blind randomized clinical trial. Sixteen children with cerebral palsy (CP), aged 12-18 years, with a diagnosis of spastic diplegia, were randomly allocated to a slow loaded sit-to-stand exercise group (n=8) and a self-paced loaded sit-to-stand exercise group (n=8). Loaded sit-to-stand exercise was conducted at home for 15min, 4 sets per day, 3-4days per week, for 6 weeks. The patients were evaluated immediately before the intervention and after the training. Lower limb muscle strength using a hand-held dynamometer, selective voluntary motor control using SCALE, 6-min walk distance (6MWD), and Physiological Cost Index (PCI) were measured. The 6MWD showed a significant difference before and after intervention. PCI showed a significant difference between the two groups and the two time points. 6MWD and the PCI improved after intervention in the slow sit-to-stand exercise group. Compared to loaded sit-to-stand exercise at a regular speed, slow low-loaded sit-to-stand exercise improved the 6MWD and PCI in children with CP, suggesting that this decrease in speed during exercise improves the physiological cost of walking in these children. Copyright © 2016 Elsevier Ltd. All rights reserved.
Al-Johani, Ahmed H; Kachanathu, Shaji John; Ramadan Hafez, Ashraf; Al-Ahaideb, Abdulaziz; Algarni, Abdulrahman D; Meshari Alroumi, Abdulmohesn; Alanezi, Aqeel M
2014-06-01
[Purpose] Osteoarthritis (OA) of the knee is the most common form of joint disease. It is one of the major causes of impaired function that reduces quality of life (QOL) worldwide. The purpose of this study was to compare exercise treatments for hamstring and quadriceps strength in the management of knee osteoarthritis. [Subjects and Methods] Forty patients with OA knee, aged 50-65 years were divided into 2 groups. The first group (57.65±4.78 years) received hot packs and performed strengthening exercises for the quadriceps and hamstring, and stretching exercises for the hamstring. The second group (58.15±5.11 years) received hot packs and performed strengthening exercises for only the quadriceps, and stretching exercise for the hamstring. Outcome measures were the WOMAC (Western Ontario and McMaster Universities OA index questionnaire), Visual Analogue Scale (VAS) assessment of pain, the Fifty-Foot Walk Test (FWS), and Handheld dynamometry. [Results] There was a significant difference between the groups. The first group showed a more significant result than the second group. [Conclusion] Strengthening of the hamstrings in addition to strengthening of the quadriceps was shown to be beneficial for improving subjective knee pain, range of motion and decreasing the limitation of functional performance of patients with knee osteoarthritis.
NASA Astrophysics Data System (ADS)
Hakonen, Aron; Rindzevicius, Tomas; Schmidt, Michael Stenbæk; Andersson, Per Ola; Juhlin, Lars; Svedendahl, Mikael; Boisen, Anja; Käll, Mikael
2016-01-01
Threats from chemical warfare agents, commonly known as nerve gases, constitute a serious security issue of increasing global concern because of surging terrorist activity worldwide. However, nerve gases are difficult to detect using current analytical tools and outside dedicated laboratories. Here we demonstrate that surface-enhanced Raman scattering (SERS) can be used for sensitive detection of femtomol quantities of two nerve gases, VX and Tabun, using a handheld Raman device and SERS substrates consisting of flexible gold-covered Si nanopillars. The substrate surface exhibits high droplet adhesion and nanopillar clustering due to elasto-capillary forces, resulting in enrichment of target molecules in plasmonic hot-spots with high Raman enhancement. The results may pave the way for strategic life-saving SERS detection of chemical warfare agents in the field.Threats from chemical warfare agents, commonly known as nerve gases, constitute a serious security issue of increasing global concern because of surging terrorist activity worldwide. However, nerve gases are difficult to detect using current analytical tools and outside dedicated laboratories. Here we demonstrate that surface-enhanced Raman scattering (SERS) can be used for sensitive detection of femtomol quantities of two nerve gases, VX and Tabun, using a handheld Raman device and SERS substrates consisting of flexible gold-covered Si nanopillars. The substrate surface exhibits high droplet adhesion and nanopillar clustering due to elasto-capillary forces, resulting in enrichment of target molecules in plasmonic hot-spots with high Raman enhancement. The results may pave the way for strategic life-saving SERS detection of chemical warfare agents in the field. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06524k
Wang, Tsae-Jyy; Belza, Basia; Elaine Thompson, F; Whitney, Joanne D; Bennett, Kim
2007-01-01
This paper reports a study of the effects of aquatic exercise on physical fitness (flexibility, strength and aerobic fitness), self-reported physical functioning and pain in adults with osteoarthritis of the hip or knee. Osteoarthritis is a common cause of disability and a primary reason for hip and knee joint replacement. Exercise is important for preventing and/or managing the functional limitations associated with joint disease. Aquatic exercise is thought to be beneficial and is often recommended for people with osteoarthritis; however, few studies have examined the effects on people with osteoarthritis, and these have yielded inconsistent results. A two-group randomized controlled trial with a convenience sample was used. Participants were recruited from community sources and randomly assigned to a 12-week aquatic programme or a non-exercise control condition. Data for 38 participants were collected at baseline, week 6, and week 12 during 2003 and 2004. Instruments were a standard plastic goniometer, a handheld dynamometer, the 6-minute walk test, the multidimensional Health Assessment Questionnaire, and a visual analogue scale for pain. Repeated measures analysis of variance showed that aquatic exercise statistically significantly improved knee and hip flexibility, strength and aerobic fitness, but had no effect on self-reported physical functioning and pain. The exercise adherence rate was 81.7%, and no exercise-related adverse effect was observed or reported. Beneficial short-term effects of aquatic exercise were found in adults with osteoarthritis of the hip or knee. Although the programme may not offer pain relief or self-reported improvements in physical functioning, results suggest that aquatic exercise does not worsen the joint condition or result in injury. Nurses engaging in disease management and health promotion for these patients should consider recommending or implementing aquatic classes for patients.
Study of Hand-Held Fire Extinguishers Aboard Civil Aviation Aircraft.
1982-06-01
or combustion products of the polymers used in aircraft construction have been found to include carbon monoxide (CO), carbon dioxide (CO ), hydrogen...toxicity rating, and ease of cleanup. The extinguishing agents used in this country for hand portable fire extinguishers are Carbon Dioxide, water, Halon...point where combustion stops." " Carbon dioxide fire extinguishing systems are useful within the limits of this standard in extinguishing fires in
Muscular Activation During Plyometric Exercises in 90° of Glenohumeral Joint Abduction
Ellenbecker, Todd S.; Sueyoshi, Tetsuro; Bailie, David S.
2015-01-01
Background: Plyometric exercises are frequently used to increase posterior rotator cuff and periscapular muscle strength and simulate demands and positional stresses in overhead athletes. The purpose of this study was to provide descriptive data on posterior rotator cuff and scapular muscle activation during upper extremity plyometric exercises in 90° of glenohumeral joint abduction. Hypothesis: Levels of muscular activity in the posterior rotator cuff and scapular stabilizers will be high during plyometric shoulder exercises similar to previously reported electromyographic (EMG) levels of shoulder rehabilitation exercises. Study Design: Descriptive laboratory study. Methods: Twenty healthy subjects were tested using surface EMG during the performance of 2 plyometric shoulder exercises: prone external rotation (PERP) and reverse catch external rotation (RCP) using a handheld medicine ball. Electrode application included the upper and lower trapezius (UT and LT, respectively), serratus anterior (SA), infraspinatus (IN), and the middle and posterior deltoid (MD and PD, respectively) muscles. A 10-second interval of repetitive plyometric exercise (PERP) and 3 repetitions of RCP were sampled. Peak and average normalized EMG data were generated. Results: Normalized peak and average IN activity ranged between 73% and 102% and between 28% and 52% during the plyometric exercises, respectively, with peak and average LT activity measured between 79% and 131% and between 31% and 61%. SA activity ranged between 76% and 86% for peak and between 35% and 37% for average activity. Muscular activity levels in the MD and PD ranged between 49% and 72% and between 12% and 33% for peak and average, respectively. Conclusion: Moderate to high levels of muscular activity were measured in the rotator cuff and scapular stabilizers during these plyometric exercises with the glenohumeral joint abducted 90°. PMID:25553216
Muscular activation during plyometric exercises in 90° of glenohumeral joint abduction.
Ellenbecker, Todd S; Sueyoshi, Tetsuro; Bailie, David S
2015-01-01
Plyometric exercises are frequently used to increase posterior rotator cuff and periscapular muscle strength and simulate demands and positional stresses in overhead athletes. The purpose of this study was to provide descriptive data on posterior rotator cuff and scapular muscle activation during upper extremity plyometric exercises in 90° of glenohumeral joint abduction. Levels of muscular activity in the posterior rotator cuff and scapular stabilizers will be high during plyometric shoulder exercises similar to previously reported electromyographic (EMG) levels of shoulder rehabilitation exercises. Descriptive laboratory study. Twenty healthy subjects were tested using surface EMG during the performance of 2 plyometric shoulder exercises: prone external rotation (PERP) and reverse catch external rotation (RCP) using a handheld medicine ball. Electrode application included the upper and lower trapezius (UT and LT, respectively), serratus anterior (SA), infraspinatus (IN), and the middle and posterior deltoid (MD and PD, respectively) muscles. A 10-second interval of repetitive plyometric exercise (PERP) and 3 repetitions of RCP were sampled. Peak and average normalized EMG data were generated. Normalized peak and average IN activity ranged between 73% and 102% and between 28% and 52% during the plyometric exercises, respectively, with peak and average LT activity measured between 79% and 131% and between 31% and 61%. SA activity ranged between 76% and 86% for peak and between 35% and 37% for average activity. Muscular activity levels in the MD and PD ranged between 49% and 72% and between 12% and 33% for peak and average, respectively. Moderate to high levels of muscular activity were measured in the rotator cuff and scapular stabilizers during these plyometric exercises with the glenohumeral joint abducted 90°.
Howle, Timothy C; Dimmock, James A; Ntoumanis, Nikos; Chatzisarantis, Nikos L D; Sparks, Cassandra; Jackson, Ben
2017-12-01
We tested the effects of advertisements about a fictitious exercise class-derived using the theoretical constructs of agency and communion-on recipients' perceptions about, and interest in, the class. The final sample consisted of 150 adults (M age = 44.69, SD = 15.83). Results revealed that participants who received a communal-oriented message reported significantly greater exercise task self-efficacy and more positive affective attitudes relative to those who received an agentic-oriented message. Communal (relative to agentic) messages were also indirectly responsible for greater intentions to attend the class, via more positive self-efficacy beliefs and affective attitudes. These findings were obtained despite the use of another manipulation to orient participants to either agency or communion goals. The results indicate that the primacy of communion over agency for message recipients may extend to exercise settings and may occur irrespective of whether participants are situationally oriented toward agency or communion.
Chronic exercise conditioning has been shown to alter basal thermoregulatory processes as well as the response to inflammatory agents. Two such agents, lipopolysaccharide (LPS) and turpentine (TPT) are inducers of fever in rats. LPS, given intraperitoneally (i.p.), involves a sys...
Saad, Marcelo Camargo; Vasconcelos, Rodrigo Antunes de; Mancinelli, Letícia Villani de Oliveira; Munno, Matheus Soares de Barros; Liporaci, Rogério Ferreira; Grossi, Débora Bevilaqua
2018-04-04
To evaluate the effect of three types of exercise intervention in patients with patellofemoral pain and to verify the contributions of each intervention to pain control, function, and lower extremity kinematics. A randomized controlled, single-blinded trial was conducted. Forty women with patellofemoral pain were randomly allocated into four groups: hip exercises, quadriceps exercises, stretching exercises and a control group (no intervention). Pain (using a visual analog scale), function (using the Anterior Knee Pain Scale), hip and quadriceps strength (using a handheld isometric dynamometer) and measuring lower limb kinematics during step up and down activities were evaluated at baseline and 8 weeks post intervention. All treatment groups showed significant improvements on pain and Anterior Knee Pain Scale after intervention with no statistically significant differences between groups except when compared to the control group. Only hip and quadriceps groups demonstrated improvements in muscle strength and knee valgus angle during the step activities. Hip strengthening exercises were not more effective for pain relief and function compared to quadriceps or stretching exercises in females with patellofemoral pain. Only hip and quadriceps groups were able to decrease the incidence of dynamic valgus during step-down activity. This study was approved by Brazilian Clinical Trials Registry registration number: RBR-6tc7mj (http://www.ensaiosclinicos.gov.br/rg/RBR-6tc7mj/). Copyright © 2018 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.
Development of a bacteriophage displayed peptide library and biosensor
NASA Astrophysics Data System (ADS)
Chin, Robert C.; Salazar, Noe; Mayo, Michael W.; Villavicencio, Victor I.; Taylor, Richard B.; Chambers, James P.; Valdes, James J.
1996-04-01
A miniaturized, handheld biosensor for identification of hazardous biowarfare agents with high specificity is being developed. An innovative biological recognition system based on bacteriophage displayed peptide receptors will be utilized in conjunction with the miniature biosensor technology being developed. A bacteriophage library has been constructed to provide the artificial receptors. The library can contain millions of bacteriophage with randomly displayed peptide sequences in the phage outer protein coat which act as binding sites for the agents of interest. This library will be used to 'bio-pan' for phages that bind to a number of toxins and infectious agents and can, thus, provide an endless supply of low cost, reliable, specific, and stable artificial receptors. The biosensor instrument will utilize evanescent wave, planar waveguide, far-red dyes, diode laser and miniature circuit technologies for performance and portability.
Toward the Realization of a Compact Chemical Sensor Platform using Quantum Cascade Lasers
2015-09-01
bromide (KBr) beamsplitter and a mercury cadmium telluride ( MCT )-A (narrow band – 650 cm-1 cutoff) detector . Each spectrum was acquired at a resolution...focuses on increasing speed, sensitivity, and selectivity, while reducing size and cost. Although the current state-of-the-art vapor detector (Joint...Chemical Agent Detector (JCAD)) is lightweight, handheld, and easily attaches to a belt, it still provides added bulk to a soldier on foot patrol. Both
Kinsella, Rita; Cowan, Sallie M; Watson, Lyn; Pizzari, Tania
2017-01-01
Subacromial pain syndrome (SPS) involving rotator cuff tendinopathy is a common cause of shoulder pain and disability. Evidence suggests that structured physiotherapy may be as effective as surgery in this condition with significant improvements demonstrated in trials involving scapular retraining, rotator cuff strengthening and flexibility exercises. Most published programs typically utilise isotonic concentric and/or eccentric strengthening modes. Recently, immediate analgesic effects and muscle strength gains following heavy-load isometric exercises in lower limb tendinopathy conditions have been observed. It is pertinent to ascertain whether such outcomes can be replicated in SPS/rotator cuff tendinopathy. The primary aim of this study is to establish the feasibility of undertaking a full-scale randomised controlled trial (RCT) that compares the effects of isometric, isotonic concentric and isotonic eccentric rotator cuff contractions when used as part of a semi-standardised exercise-based physiotherapy program in patients diagnosed with SPS. The secondary aim is to explore potential trends or treatment effects of the exercise intervention. Thirty-six participants diagnosed with SPS will be randomised to one of three intervention groups and undergo a one-on-one exercise-based physiotherapy intervention, involving scapular and rotator cuff muscle retraining and strengthening. Each group will utilise a different mode of rotator cuff strengthening-isometric, isotonic concentric or isotonic eccentric. Rotator cuff tendon responses to isometric loading are not yet established in the literature; hence, individualised, progressive loading will be used in this pilot study in accordance with symptoms. The intervention will involve two phases: during Phase 1 (weeks 1-6) participants undertake the active group-specific physiotherapy treatment; in Phase 2 (weeks 6-12), they undertake a progressive, but no longer group-specific exercise program. To determine feasibility, an evaluation of key study parameters including (a) ease of recruitment (rate and number as well as suitability of the assessment algorithm), (b) adherence to all phases of the exercise intervention including home program compliance and logbook completion, (c) participant non-completion (drop out number and rate) and (d) adverse events (nature and number) will be undertaken. Secondary outcomes will measure immediate effects: (i) within-treatment changes in pain perception (verbal rating scale (VRS) and shoulder muscle strength (hand-held dynamometer) as well as longer-term changes: (ii) shoulder-related symptoms and disability (Western Ontario Rotator Cuff Index (WORC) and Shoulder Pain and Disability Index (SPADI)), (iii) perception of pain (11-point numerical rating scale (NRS), (iv) shoulder muscle strength (hand-held dynamometer) and (v) perceived global rating of change score. The immediate within-treatment assessment of pain and muscle strength will be undertaken in treatments 2 and 3, and the longer term measures will be collected at the primary (conclusion of Phase 1 at 6 weeks) and secondary (conclusion of Phase 2 at 12 weeks) end-points of the study. The findings of this pilot study will permit evaluation of this study design for a full-scale RCT. Australian New Zealand Clinical Trials Registry, ACTRN12616001676404.
Handheld computing in pathology
Park, Seung; Parwani, Anil; Satyanarayanan, Mahadev; Pantanowitz, Liron
2012-01-01
Handheld computing has had many applications in medicine, but relatively few in pathology. Most reported uses of handhelds in pathology have been limited to experimental endeavors in telemedicine or education. With recent advances in handheld hardware and software, along with concurrent advances in whole-slide imaging (WSI), new opportunities and challenges have presented themselves. This review addresses the current state of handheld hardware and software, provides a history of handheld devices in medicine focusing on pathology, and presents future use cases for such handhelds in pathology. PMID:22616027
Marshall, A J; Kettle, M A; Barritt, D W
1980-09-01
1 Indoramin, an alpha-adrenoreceptor blocking agent has been given as a third agent to patients with severe hypertension treated with adequate doses of a beta-adrenoceptor blocking drug and a thiazide diuretic. 2 A further fall in blood pressure followed the addition of indoramin. With 75 mg twice daily this was on average a fall of 12% of mean arterial pressure in the supine position, 16% standing an 17% after exercise. 3 The rise in blood pressure caused by isometric exercise was not altered by indoramin. 4 Indoramin slowed the heart rate. On 75 mg twice daily the reduction was 14% at rest and 19% after exercise. 5 Side effects of indoramin were sedation, sleep disturbance and vivid dreams.
Backer, H D; Collins, S
1999-04-01
To test the feasibility of using handheld, battery-operated chemical analyzers by EMS personnel in a wilderness environment to aid in the diagnosis and management of heat illness. During the summer of 1996, 3 portable clinical analyzers (i-STAT Corp, Princeton, NJ) were kept at different locations along the main hiking trail into the Grand Canyon. An operational protocol was designed for field use, and Park Service EMS personnel used the instruments at their discretion, primarily to determine serum sodium concentration and identify cases of hyponatremia. Data were collected on all EMS encounters. This study reviews our experience with the instruments. The i-STAT analyzer was used for 64 patients in the backcountry; of these uses, at least 22 were in the field and the remainder in backcountry ranger stations. Eight error messages were recorded in 6 patients. Subsequently, all but 1 had a successful determination. Among patients evacuated for further evaluation and care, serum sodium values were highly consistent with later analysis using standard laboratory equipment. The instrument was used in 31 (48%) of 64 of patients evaluated and released for self-treatment and self-evacuation, and 31 (36%) of 87 of patients evacuated by EMS personnel from the canyon. Nine cases of hyponatremia were confirmed in the field, allowing appropriate intervention. Portable clinical analyzers can reliably be used in a hot wilderness environment. In our application, it allowed identification of exercise-associated hyponatremia, an important cause of serious heat illness during endurance exercise in a hot environment. The results helped make treatment and disposition decisions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
RODACY,PHILIP J.; REBER,STEPHEN D.; SIMONSON,ROBERT J.
This report examines the market potential of a miniature, hand-held Ion Mobility Spectrometer. Military and civilian markets are discussed, as well as applications in a variety of diverse fields. The strengths and weaknesses of competing technologies are discussed. An extensive Ion Mobility Spectrometry (IMS) bibliography is included. The conclusions drawn from this study are: (1) There are a number of competing technologies that are capable of detecting explosives, drugs, biological, or chemical agents. The IMS system currently represents the best available compromise regarding sensitivity, specificity, and portability. (2) The military market is not as large as the commercial market, butmore » the military services are more likely to invest R and D funds in the system. (3) Military applications should be addressed before commercial applications are addressed. (4) There is potentially a large commercial market for rugged, hand-held Ion Mobility Spectrometer systems. Commercial users typically do not invest R and D funds in this type of equipment rather, they wait for off-the-shelf availability.« less
Photoacoustic cystography using handheld dual modal clinical ultrasound photoacoustic imaging system
NASA Astrophysics Data System (ADS)
Sivasubramanian, Kathyayini; Periyasamy, Vijitha; Austria, Dienzo Rhonnie; Pramanik, Manojit
2018-02-01
Vesicoureteral reflux is the abnormal flow of urine from your bladder back up the tubes (ureters) that connect your kidneys to your bladder. Normally, urine flows only down from your kidneys to your bladder. Vesicoureteral reflux is usually diagnosed in infants and children. The disorder increases the risk of urinary tract infections, which, if left untreated, can lead to kidney damage. X-Ray cystography is used currently to diagnose this condition which uses ionising radiation, making it harmful for patients. In this work we demonstrate the feasibility of imaging the urinary bladder using a handheld clinical ultrasound and photoacoustic dual modal imaging system in small animals (rats). Additionally, we demonstrate imaging vesicoureteral reflux using bladder mimicking phantoms. Urinary bladder imaging is done with the help of contrast agents like black ink and gold nanoparticles which have high optical absorption at 1064 nm. Imaging up to 2 cm was demonstrated with this system. Imaging was done at a framerate of 5 frames per second.
NASA Technical Reports Server (NTRS)
2001-01-01
This photo shows the Handheld Diffusion Test Cell (HH-DTC) apparatus flown on the Space Shuttle. Similar cells (inside the plastic box) will be used in the Observable Protein Crystal Growth Apparatus (OPCGA) to be operated aboard the International Space Station (ISS). The principal investigator is Dr. Alex McPherson of the University of California, Irvine. Each individual cell comprises two sample chambers with a rotating center section that isolates the two from each other until the start of the experiment and after it is completed. The cells are made from optical-quality quartz glass to allow photography and interferometric observations. Each cell has a small light-emitting diode and lens to back-light the solution. In protein crystal growth experiments, a precipitating agent such as a salt solution is used to absorb and hold water but repel the protein molecules. This increases the concentration of protein until the molecules nucleate to form crystals. This cell is one of 96 that make up the experiment module portion of the OPCGA.
NASA Technical Reports Server (NTRS)
2001-01-01
This photo shows an individual cell from the Handheld Diffusion Test Cell (HH-DTC) apparatus flown on the Space Shuttle. Similar cells will be used in the Observable Protein Crystal Growth Apparatus (OPCGA) to be operated aboard the International Space Station (ISS). The principal investigator is Dr. Alex McPherson of the University of California, Irvine. Each individual cell comprises two sample chambers with a rotating center section that isolates the two from each other until the start of the experiment and after it is completed. The cells are made from optical-quality quartz glass to allow photography and interferometric observations. Each cell has a small light-emitting diode and lens to back-light the solution. In protein crystal growth experiments, a precipitating agent such as a salt solution is used to absorb and hold water but repel the protein molecules. This increases the concentration of protein until the molecules nucleate to form crystals. This cell is one of 96 that make up the experiment module portion of the OPCGA.
Effects of antihypertensive agents on blood pressure during exercise.
Arita, M; Hashizume, T; Wanaka, Y; Handa, S; Nakamura, C; Fujiwara, S; Nishio, I
2001-11-01
The relationship between blood pressure (BP) and cardiovascular morbidity has been appreciated for many years. Casual BP may not be representative of the pressure at other times. It is recognized that BP during exercise may be a more accurate predictor than casual BP. There is, however, little information about the effects of antihypertensive drugs on the BP during exercise. This study was designed to investigate the effects of various antihypertensive agents on BP during exercise. Sixty-four patients (age, 49+/-10 years) with untreated essential hypertension (WHO I, II) were studied during a supine ergometric exercise regimen. A graded exercise test was started at a workload of 50 W, and the load was increased by 25 W every 3 min. The hemodynamic responses to exercise were evaluated by changes in systolic and diastolic BP (SBP, DBP) and heart rate (HR). Plasma norepinephrine (NE) levels were measured at rest and during submaximal exercise, and before and after 4 weeks of treatment with metoprolol (METO), doxazosin (DOXA), trichlormethiazide (TCTZ), nifedipine (NIFE), amlodipine (AMLO) and temocapril (TEMO) between left ventricular mass index (LVMI) and BP values at rest, during exercise, and during the recovery period after exercise were assessed by multiple regression analysis. The stepwise selection (forward conditional) method showed that LVMI was significantly associated with SBP during submaximal exercise and during the recovery period. All antihypertensive treatments decreased SBP and DBP (p<0.01) at rest. METO, AMLO and TEMO significantly lowered SBP (p<0.05) during exercise, whereas DOXA, TCTZ and NIFE induced no change in SBP. The exercise-induced increase of plasma NE was further enhanced by METO and NIFE but not by AMLO, DOXA, or TCTZ, and it was significantly suppressed by TEMO (p<0.01). These results suggest that BP during exercise is more highly associated with the progression of left ventricular hypertrophy (LVH) than is casual BP. Because antihypertensive agents differ in their effects on exercise hemodynamics, we recommend that hemodynamic factors during exercise be considered when selecting the optimal antihypertensive medication for highly active patients.
NASA Astrophysics Data System (ADS)
Liu, Yu-Hang; Xu, Yu; Chan, Kim Chuan; Mehta, Kalpesh; Thakor, Nitish; Liao, Lun-De
2017-02-01
Stroke is the second leading cause of death worldwide. Rapid and precise diagnosis is essential to expedite clinical decision and improve functional outcomes in stroke patients; therefore, real-time imaging plays an important role to provide crucial information for post-stroke recovery analysis. In this study, based on the multi-wavelength laser and 18.5 MHz array-based ultrasound platform, a real-time handheld photoacoustic (PA) system was developed to evaluate cerebrovascular functions pre- and post-stroke in rats. Using this system, hemodynamic information such as cerebral blood volume (CBV) can be acquired for assessment. One rat stroke model (i.e., photothrombotic ischemia (PTI)) was employed for evaluating the effect of local ischemia. For achieving better intrinsic PA contrast, Vantage and COMSOL simulations were applied to optimize the light delivery (e.g., interval between two arms) from customized fiber bundle, while phantom experiment was conducted to evaluate the imaging performance of this system. Results of phantom experiment showed that hairs ( 150 μm diameter) and pencil lead (500 μm diameter) can be imaged clearly. On the other hand, results of in vivo experiments also demonstrated that stroke symptoms can be observed in PTI model poststroke. In the near future, with the help of PA specific contrast agent, the system would be able to achieve blood-brain barrier leakage imaging post-stroke. Overall, the real-time handheld PA system holds great potential in disease models involving impairments in cerebrovascular functions.
Patient Perceptions of Physician Use of Handheld Computers
Houston, Thomas K.; Ray, Midge N.; Crawford, Myra A.; Giddens, Tonya; Berner, Eta S.
2003-01-01
Background Handheld computers have advantages for physicians, including portability and integration into office workflow. However, negative patient perceptions of physician use of handheld computers in the examining room might limit integration. Objective To survey patients’ perceptions of handheld use, and compare those with their providers’ perceptions. Methods A survey of patient attitudes toward handhelds was conducted among patients at a low-income university clinic. Internal Medicine residents providing care were also surveyed. Results Patients (N=93) were mostly female (79%) and ethnic minorities (67%) with average age of 39. Only 10% of patients did not like the idea of a handheld computer in the exam room. Other negative attitudes were also seen in a minority of patients. Some physicians (23%) reported reservations about using the handheld with patients. Conclusions Negative attitudes were rare among patients, but some providers were concerned about using the handheld in the exam room. PMID:14728182
Ranieri, Nicola; Tabernero, Patricia; Green, Michael D.; Verbois, Leigh; Herrington, James; Sampson, Eric; Satzger, R. Duane; Phonlavong, Chindaphone; Thao, Khamxay; Newton, Paul N.; Witkowski, Mark R.
2014-01-01
There is an urgent need for accurate and inexpensive handheld instruments for the evaluation of medicine quality in the field. A blinded evaluation of the diagnostic accuracy of the Counterfeit Detection Device 3 (CD-3), developed by the US Food and Drug Administration Forensic Chemistry Center, was conducted in the Lao People's Democratic Republic. Two hundred three samples of the oral antimalarial artesunate were compared with authentic products using the CD-3 by a trainer and two trainees. The specificity (95% confidence interval [95% CI]), sensitivity (95% CI), positive predictive value (95% CI), and negative predictive value (95% CI) of the CD-3 for detecting counterfeit (falsified) artesunate were 100% (93.8–100%), 98.4% (93.8–99.7%), 100% (96.2–100%), and 97.4% (90.2–99.6%), respectively. Interobserver agreement for 203 samples of artesunate was 100%. The CD-3 holds promise as a relatively inexpensive and easy to use instrument for field evaluation of medicines, potentially empowering drug inspectors, customs agents, and pharmacists. PMID:25266348
Rudisill, Toni M; Zhu, Motao
2017-05-12
Cell phone use behaviors are known to vary across demographic sub-groups and geographic locations. This study examined whether universal hand-held calling while driving bans were associated with lower road-side observed hand-held cell phone conversations across drivers of different ages (16-24, 25-59, ≥60 years), sexes, races (White, African American, or other), ruralities (suburban, rural, or urban), and regions (Northeast, Midwest, South, and West). Data from the 2008-2013 National Occupant Protection Use Survey were merged with states' cell phone use while driving legislation. The exposure was presence of a universal hand-held cell phone ban at time of observation. Logistic regression was used to assess the odds of drivers having a hand-held cell phone conversation. Sub-groups differences were assessed using models with interaction terms. When universal hand-held cell phone bans were effective, hand-held cell phone conversations were lower across all driver demographic sub-groups and regions. Sub-group differences existed among the sexes (p-value, <0.0001) and regions (p-value, 0.0003). Compared to states without universal hand-held cell phone bans, the adjusted odds ratio (aOR) of a driver hand-held phone conversation was 0.34 [95% confidence interval (CI): 0.28, 0.41] for females versus 0.47 (CI 0.40, 0.55) for males and 0.31 (CI 0.25, 0.38) for drivers in Western states compared to 0.47 (CI 0.30, 0.72) in the Northeast and 0.50 (CI 0.38, 0.66) in the South. The presence of universal hand-held cell phone bans were associated lower hand-held cell phone conversations across all driver sub-groups and regions. Hand-held phone conversations were particularly lower among female drivers and those from Western states when these bans were in effect. Public health interventions concerning hand-held cell phone use while driving could reasonably target all drivers.
At Ease in the Handheld World.
ERIC Educational Resources Information Center
Levinson, Eliot; Grohe, Barbara
2001-01-01
Provides educational decision-makers with an overview of the offerings and issues related to adopting handheld computers. Describes several handheld products available to schools, including: Palm, iPAQ, Mindsurf, Symbol Technologies, Texas Instruments, and Gateway Handspring Visor. Compares handhelds to PCs, in terms of functionality, operating…
Sievertsen, Niels; Carreira, Erick M
2018-02-01
Mobile devices such as smartphones are carried in the pockets of university students around the globe and are increasingly cheap to come by. These portable devices have evolved into powerful and interconnected handheld computers, which, among other applications, can be used as advanced learning tools and providers of targeted, curated content. Herein, we describe Apoc Social (Advanced Problems in Organic Chemistry Social), a mobile application that assists both learning and teaching college-level organic chemistry both in the classroom and on the go. With more than 750 chemistry exercises available, Apoc Social facilitates collaborative learning through discussion boards and fosters enthusiasm for complex organic chemistry.
Smartphone ECG aids real time diagnosis of palpitations in the competitive college athlete.
Peritz, David C; Howard, Austin; Ciocca, Mario; Chung, Eugene H
2015-01-01
Rapidly detecting dangerous arrhythmias in a symptomatic athlete continues to be an elusive goal. The use of handheld smartphone electrocardiogram (ECG) monitors could represent a helpful tool connecting the athletic trainer to the cardiologist. Six college athletes presented to their athletic trainers complaining of palpitations during exercise. A single lead ECG was performed using the AliveCor Heart Monitor and sent wirelessly to the Team Cardiologist who confirmed an absence of dangerous arrhythmia. AliveCor monitoring has the potential to enhance evaluation of symptomatic athletes by allowing trainers and team physicians to make diagnosis in real-time and facilitate faster return to play. Copyright © 2015 Elsevier Inc. All rights reserved.
Information infrastructure for emergency medical services.
Orthner, Helmuth; Mishra, Ninad; Terndrup, Thomas; Acker, Joseph; Grimes, Gary; Gemmill, Jill; Battles, Marcie
2005-01-01
The pre-hospital emergency medical and public safety information environment is nearing a threshold of significant change. The change is driven in part by several emerging technologies such as secure, high-speed wireless communication in the local and wide area networks (wLAN, 3G), Geographic Information Systems (GIS), Global Positioning Systems (GPS), and powerful handheld computing and communication services, that are of sufficient utility to be more widely adopted. We propose a conceptual model to enable improved clinical decision making in the pre-hospital environment using these change agents.
Image Quality Characteristics of Handheld Display Devices for Medical Imaging
Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo
2013-01-01
Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113
Students' framing of laboratory exercises using infrared cameras
NASA Astrophysics Data System (ADS)
Haglund, Jesper; Jeppsson, Fredrik; Hedberg, David; Schönborn, Konrad J.
2015-12-01
Thermal science is challenging for students due to its largely imperceptible nature. Handheld infrared cameras offer a pedagogical opportunity for students to see otherwise invisible thermal phenomena. In the present study, a class of upper secondary technology students (N =30 ) partook in four IR-camera laboratory activities, designed around the predict-observe-explain approach of White and Gunstone. The activities involved central thermal concepts that focused on heat conduction and dissipative processes such as friction and collisions. Students' interactions within each activity were videotaped and the analysis focuses on how a purposefully selected group of three students engaged with the exercises. As the basis for an interpretative study, a "thick" narrative description of the students' epistemological and conceptual framing of the exercises and how they took advantage of the disciplinary affordance of IR cameras in the thermal domain is provided. Findings include that the students largely shared their conceptual framing of the four activities, but differed among themselves in their epistemological framing, for instance, in how far they found it relevant to digress from the laboratory instructions when inquiring into thermal phenomena. In conclusion, the study unveils the disciplinary affordances of infrared cameras, in the sense of their use in providing access to knowledge about macroscopic thermal science.
The effects of pilates on balance, mobility and strength in patients with multiple sclerosis.
Guclu-Gunduz, Arzu; Citaker, Seyit; Irkec, Ceyla; Nazliel, Bijen; Batur-Caglayan, Hale Zeynep
2014-01-01
Although there are evidences as to Pilates developing dynamic balance, muscle strength and flexibility in healthy people, evidences related to its effects on Multiple Sclerosis patients are insufficient. The aims of this study were to investigate the effects of Pilates on balance, mobility, and strength in ambulatory patients with Multiple Sclerosis. Twenty six patients were divided into two groups as experimental (n = 18) and control (n = 8) groups for an 8-week treatment program. The experimental group underwent Pilates and the control group did abdominal breathing and active extremity exercises at home. Balance and mobility were measured with Berg Balance Scale and Timed up and go test, upper and lower muscle strength with hand-held dynamometer. Confidence in balance skills while performing daily activities was evaluated with Activities Specific Balance Confidence Scale. Improvements were observed in balance, mobility, and upper and lower extremity muscle strength in the Pilates group (p < 0.05). No significant differences in any outcome measures were observed in the control group (p > 0.05). Due to its structure which is made up of balance and strengthening exercises, Pilates training may develop balance, mobility and muscle strength of MS patients. For this reason, we think that, Pilates exercises which are appropriate for the disability level of the patient may be suggested.
30 CFR 57.7053 - Moving hand-held drills.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Moving hand-held drills. 57.7053 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface and Underground § 57.7053 Moving hand-held drills. Before hand-held...
ERIC Educational Resources Information Center
Joyner, Amy
2003-01-01
Handheld computers provide students tremendous computing and learning power at about a 10th the cost of a regular computer. Describes the evolution of handhelds; provides some examples of their uses; and cites research indicating they are effective classroom tools that can improve efficiency and instruction. A sidebar lists handheld resources.…
30 CFR 57.7053 - Moving hand-held drills.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Moving hand-held drills. 57.7053 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface and Underground § 57.7053 Moving hand-held drills. Before hand-held...
30 CFR 57.7053 - Moving hand-held drills.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Moving hand-held drills. 57.7053 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface and Underground § 57.7053 Moving hand-held drills. Before hand-held...
30 CFR 57.7053 - Moving hand-held drills.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Moving hand-held drills. 57.7053 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface and Underground § 57.7053 Moving hand-held drills. Before hand-held...
30 CFR 57.7053 - Moving hand-held drills.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Moving hand-held drills. 57.7053 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling-Surface and Underground § 57.7053 Moving hand-held drills. Before hand-held...
30 CFR 57.12033 - Hand-held electric tools.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...
30 CFR 57.12033 - Hand-held electric tools.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...
30 CFR 57.12033 - Hand-held electric tools.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...
30 CFR 57.12033 - Hand-held electric tools.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...
30 CFR 57.12033 - Hand-held electric tools.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-24
... Communications System Server Software, Wireless Handheld Devices and Battery Packs; Notice of Investigation..., wireless handheld devices and battery packs by reason of infringement of certain claims of U.S. Patent Nos... certain wireless communications system server software, wireless handheld devices or battery packs that...
Aerobic exercise reduces blood pressure in resistant hypertension.
Dimeo, Fernando; Pagonas, Nikolaos; Seibert, Felix; Arndt, Robert; Zidek, Walter; Westhoff, Timm H
2012-09-01
Regular physical exercise is broadly recommended by current European and American hypertension guidelines. It remains elusive, however, whether exercise leads to a reduction of blood pressure in resistant hypertension as well. The present randomized controlled trial examines the cardiovascular effects of aerobic exercise on resistant hypertension. Resistant hypertension was defined as a blood pressure ≥140/90 mm Hg in spite of 3 antihypertensive agents or a blood pressure controlled by ≥4 antihypertensive agents. Fifty subjects with resistant hypertension were randomly assigned to participate or not to participate in an 8- to 12-week treadmill exercise program (target lactate, 2.0±0.5 mmol/L). Blood pressure was assessed by 24-hour monitoring. Arterial compliance and cardiac index were measured by pulse wave analysis. The training program was well tolerated by all of the patients. Exercise significantly decreased systolic and diastolic daytime ambulatory blood pressure by 6±12 and 3±7 mm Hg, respectively (P=0.03 each). Regular exercise reduced blood pressure on exertion and increased physical performance as assessed by maximal oxygen uptake and lactate curves. Arterial compliance and cardiac index remained unchanged. Physical exercise is able to decrease blood pressure even in subjects with low responsiveness to medical treatment. It should be included in the therapeutic approach to resistant hypertension.
30 CFR 56.7053 - Moving hand-held drills.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Moving hand-held drills. 56.7053 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7053 Moving hand-held drills. Before hand-held drills are moved from one...
30 CFR 56.7053 - Moving hand-held drills.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Moving hand-held drills. 56.7053 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7053 Moving hand-held drills. Before hand-held drills are moved from one...
30 CFR 56.7053 - Moving hand-held drills.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Moving hand-held drills. 56.7053 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7053 Moving hand-held drills. Before hand-held drills are moved from one...
30 CFR 56.7053 - Moving hand-held drills.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Moving hand-held drills. 56.7053 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7053 Moving hand-held drills. Before hand-held drills are moved from one...
30 CFR 56.7053 - Moving hand-held drills.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Moving hand-held drills. 56.7053 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Drilling § 56.7053 Moving hand-held drills. Before hand-held drills are moved from one...
Handheld Computers in the Classroom: Integration Strategies for Social Studies Educators.
ERIC Educational Resources Information Center
Ray, Beverly
Handheld computers have gone beyond the world of business and are now finding their way into the hands of social studies teachers and students. This paper discusses how social studies teachers can use handheld computers to aid anytime/ anywhere course management. The integration of handheld technology into the classroom provides social studies…
Handheld Computer Use in U.S. Family Practice Residency Programs
Criswell, Dan F.; Parchman, Michael L.
2002-01-01
Objective: The purpose of the study was to evaluate the uses of handheld computers (also called personal digital assistants, or PDAs) in family practice residency programs in the United States. Study Design: In November 2000, the authors mailed a questionnaire to the program directors of all American Academy of Family Physicians (AAFP) and American College of Osteopathic Family Practice (ACOFP) residency programs in the United States. Measurements: Data and patterns of the use and non-use of handheld computers were identified. Results: Approximately 50 percent (306 of 610) of the programs responded to the survey. Two thirds of the programs reported that handheld computers were used in their residencies, and an additional 14 percent had plans for implementation within 24 months. Both the Palm and the Windows CE operating systems were used, with the Palm operating system the most common. Military programs had the highest rate of use (8 of 10 programs, 80 percent), and osteopathic programs had the lowest (23 of 55 programs, 42 percent). Of programs that reported handheld computer use, 45 percent had required handheld computer applications that are used uniformly by all users. Funding for handheld computers and related applications was non-budgeted in 76percent of the programs in which handheld computers were used. In programs providing a budget for handheld computers, the average annual budget per user was $461.58. Interested faculty or residents, rather than computer information services personnel, performed upkeep and maintenance of handheld computers in 72 percent of the programs in which the computers are used. In addition to the installed calendar, memo pad, and address book, the most common clinical uses of handheld computers in the programs were as medication reference tools, electronic textbooks, and clinical computational or calculator-type programs. Conclusions: Handheld computers are widely used in family practice residency programs in the United States. Although handheld computers were designed as electronic organizers, in family practice residencies they are used as medication reference tools, electronic textbooks, and clinical computational programs and to track activities that were previously associated with desktop database applications. PMID:11751806
Handheld computer use in U.S. family practice residency programs.
Criswell, Dan F; Parchman, Michael L
2002-01-01
The purpose of the study was to evaluate the uses of handheld computers (also called personal digital assistants, or PDAs) in family practice residency programs in the United States. In November 2000, the authors mailed a questionnaire to the program directors of all American Academy of Family Physicians (AAFP) and American College of Osteopathic Family Practice (ACOFP) residency programs in the United States. Data and patterns of the use and non-use of handheld computers were identified. Approximately 50 percent (306 of 610) of the programs responded to the survey. Two thirds of the programs reported that handheld computers were used in their residencies, and an additional 14 percent had plans for implementation within 24 months. Both the Palm and the Windows CE operating systems were used, with the Palm operating system the most common. Military programs had the highest rate of use (8 of 10 programs, 80 percent), and osteopathic programs had the lowest (23 of 55 programs, 42 percent). Of programs that reported handheld computer use, 45 percent had required handheld computer applications that are used uniformly by all users. Funding for handheld computers and related applications was non-budgeted in 76percent of the programs in which handheld computers were used. In programs providing a budget for handheld computers, the average annual budget per user was 461.58 dollars. Interested faculty or residents, rather than computer information services personnel, performed upkeep and maintenance of handheld computers in 72 percent of the programs in which the computers are used. In addition to the installed calendar, memo pad, and address book, the most common clinical uses of handheld computers in the programs were as medication reference tools, electronic textbooks, and clinical computational or calculator-type programs. Handheld computers are widely used in family practice residency programs in the United States. Although handheld computers were designed as electronic organizers, in family practice residencies they are used as medication reference tools, electronic textbooks, and clinical computational programs and to track activities that were previously associated with desktop database applications.
Mickan, Sharon; Tilson, Julie K; Atherton, Helen; Roberts, Nia Wyn; Heneghan, Carl
2013-10-28
Handheld computers and mobile devices provide instant access to vast amounts and types of useful information for health care professionals. Their reduced size and increased processing speed has led to rapid adoption in health care. Thus, it is important to identify whether handheld computers are actually effective in clinical practice. A scoping review of systematic reviews was designed to provide a quick overview of the documented evidence of effectiveness for health care professionals using handheld computers in their clinical work. A detailed search, sensitive for systematic reviews was applied for Cochrane, Medline, EMBASE, PsycINFO, Allied and Complementary Medicine Database (AMED), Global Health, and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases. All outcomes that demonstrated effectiveness in clinical practice were included. Classroom learning and patient use of handheld computers were excluded. Quality was assessed using the Assessment of Multiple Systematic Reviews (AMSTAR) tool. A previously published conceptual framework was used as the basis for dual data extraction. Reported outcomes were summarized according to the primary function of the handheld computer. Five systematic reviews met the inclusion and quality criteria. Together, they reviewed 138 unique primary studies. Most reviewed descriptive intervention studies, where physicians, pharmacists, or medical students used personal digital assistants. Effectiveness was demonstrated across four distinct functions of handheld computers: patient documentation, patient care, information seeking, and professional work patterns. Within each of these functions, a range of positive outcomes were reported using both objective and self-report measures. The use of handheld computers improved patient documentation through more complete recording, fewer documentation errors, and increased efficiency. Handheld computers provided easy access to clinical decision support systems and patient management systems, which improved decision making for patient care. Handheld computers saved time and gave earlier access to new information. There were also reports that handheld computers enhanced work patterns and efficiency. This scoping review summarizes the secondary evidence for effectiveness of handheld computers and mhealth. It provides a snapshot of effective use by health care professionals across four key functions. We identified evidence to suggest that handheld computers provide easy and timely access to information and enable accurate and complete documentation. Further, they can give health care professionals instant access to evidence-based decision support and patient management systems to improve clinical decision making. Finally, there is evidence that handheld computers allow health professionals to be more efficient in their work practices. It is anticipated that this evidence will guide clinicians and managers in implementing handheld computers in clinical practice and in designing future research.
ERIC Educational Resources Information Center
Liu, Chen-Chung; Kao, L.-C.
2007-01-01
One-to-one computing environments change and improve classroom dynamics as individual students can bring handheld devices fitted with wireless communication capabilities into the classrooms. However, the screens of handheld devices, being designed for individual-user mobile application, limit promotion of interaction among groups of learners. This…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-05
... Systems, Including Software and Handheld Electronic Devices; Notice of Investigation AGENCY: U.S... software and handheld electronic devices, by reason of infringement of certain claims of U.S. Patent No 7... software and handheld electronic devices, that infringe one or more of claims 31-35, 38, 41, 51, 54, 56, 58...
ERIC Educational Resources Information Center
Chavez, Raymond Anthony
2010-01-01
Previous research conducted on the use of handheld computers in K-12 education has focused on how handheld computer use affects student motivation, engagement, and productivity. These four case studies sought to identify effective teacher practices in the integration of handhelds into the curriculum and the factors that affect those practices. The…
Brem, Matthias H; Lehrl, Siegfried; Rein, Anna K; Massute, Sylvia; Schulz-Drost, Stefan; Gelse, Kolja; Schlechtweg, Phillip M; Hennig, Friedrich F; Olk, Alexander; Jacob, Harald J; Gusinde, Johannes
2010-01-01
Prolonged hospitalization is known to be associated with a loss of cognitive performance. Does playing video games (VGs) developed to improve cognitive properties delay this loss or even lead to an increase in cognitive performance? We performed a 10-day longitudinal study of patients who received total hip arthroplasty. We compared 16 patients (6 male) aged 66 ± 9 years (mean ± standard deviation) who played Dr. Kawashima's Brain Training: How Old Is Your Brain? (Nintendo; Redmond, Washington) on a Nintendo DS handheld console with 16 control patients (6 male) aged 69 ± 14 years. We measured cognitive performance 1 day preoperation, as well as on days 2 and 9 postoperation. With the daily exercise of a specific VG by the play group, the patients' fluid intelligence (median intelligence quotient 99-106), working memory capacity, and rate of information processing significantly improved over the course of 7 postoperative days. The cognitive performance of the control group did not increase. However, the memory spans of both groups did not systematically change. Exercise with VGs can prevent the loss of cognitive performance during prolonged hospitalization.
Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito
2017-11-01
[Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.
Zhu, Motao; Rudisill, Toni M; Heeringa, Steven; Swedler, David; Redelmeier, Donald A
2016-12-01
Fourteen US states and the District of Columbia have banned handheld phone use for all drivers. We examined whether such legislation was associated with reduced handheld phone conversations among drivers aged younger than 25 years. Data from the 2008 to 2013 National Occupant Protection Use Survey were merged with states' legislation. The outcome was roadside-observed handheld phone conversation at stop signs or lights. Logistic regression was used. A total of 32,784 young drivers were observed. Relative to drivers who were observed in states without a universal handheld phone ban, the adjusted odds ratio of phone conversation was 0.42 (95% confidence interval, 0.33-0.53) for drivers who were observed in states with bans. The relative reduction in phone conversation was 46% (23%, 61%) for laws that were effective less than 1 year, 55% (32%, 70%) for 1-2 years, 63% (51%, 72%) for 2 years or more, relative to no laws. Universal handheld phone bans may be effective at reducing handheld phone use among young drivers. Copyright © 2016 Elsevier Inc. All rights reserved.
Hand Held Device for Wireless Powering and Interrogation of Biomems Sensors and Actuators
NASA Technical Reports Server (NTRS)
Simons, Rainee N (Inventor); Miranda, Felix Antonio (Inventor)
2007-01-01
A compact, hand-held device for wireless powering, interrogation and data retrieval from at least one implanted sensor. The hand-held device includes an antenna for powering an implanted sensor and for receiving data from the implanted sensor to the hand-held device for at least one of storage, display or analysis. The hand-held device establishes electromagnetic coupling with a low radiating radio frequency power inductor in the implanted sensor at a predefined separation and the antenna geometry allows for the antenna to power, interrogate and retrieve data from the implanted sensor without strapping the hand-held device to a human body housing the implanted sensor The hand-held device optionally allows for activation of the implanted sensor only during interrogation and data retrieval.
2013-01-01
Background Handheld computers and mobile devices provide instant access to vast amounts and types of useful information for health care professionals. Their reduced size and increased processing speed has led to rapid adoption in health care. Thus, it is important to identify whether handheld computers are actually effective in clinical practice. Objective A scoping review of systematic reviews was designed to provide a quick overview of the documented evidence of effectiveness for health care professionals using handheld computers in their clinical work. Methods A detailed search, sensitive for systematic reviews was applied for Cochrane, Medline, EMBASE, PsycINFO, Allied and Complementary Medicine Database (AMED), Global Health, and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases. All outcomes that demonstrated effectiveness in clinical practice were included. Classroom learning and patient use of handheld computers were excluded. Quality was assessed using the Assessment of Multiple Systematic Reviews (AMSTAR) tool. A previously published conceptual framework was used as the basis for dual data extraction. Reported outcomes were summarized according to the primary function of the handheld computer. Results Five systematic reviews met the inclusion and quality criteria. Together, they reviewed 138 unique primary studies. Most reviewed descriptive intervention studies, where physicians, pharmacists, or medical students used personal digital assistants. Effectiveness was demonstrated across four distinct functions of handheld computers: patient documentation, patient care, information seeking, and professional work patterns. Within each of these functions, a range of positive outcomes were reported using both objective and self-report measures. The use of handheld computers improved patient documentation through more complete recording, fewer documentation errors, and increased efficiency. Handheld computers provided easy access to clinical decision support systems and patient management systems, which improved decision making for patient care. Handheld computers saved time and gave earlier access to new information. There were also reports that handheld computers enhanced work patterns and efficiency. Conclusions This scoping review summarizes the secondary evidence for effectiveness of handheld computers and mhealth. It provides a snapshot of effective use by health care professionals across four key functions. We identified evidence to suggest that handheld computers provide easy and timely access to information and enable accurate and complete documentation. Further, they can give health care professionals instant access to evidence-based decision support and patient management systems to improve clinical decision making. Finally, there is evidence that handheld computers allow health professionals to be more efficient in their work practices. It is anticipated that this evidence will guide clinicians and managers in implementing handheld computers in clinical practice and in designing future research. PMID:24165786
2013-04-15
VAAR) was purchased from McGean. Hydrated basic magnesium carbonate was obtained from Pine Bluff Arsenal (Pine Bluff, AR) and was confirmed to be Mg5( CO3 ...a potential environmental exposure of approximately 29 g of the toxic yellow dyes throughout the life cycle of a single M194 signal! To mitigate this...consists of Solvent Yellow 33 as the smoke sublimating agent, hydrated basic magnesium carbonate (Mg5( CO3 )4(OH)2·4H2O) instead of sodium bicarbonate (NaHCO3
Correcting for motion artifact in handheld laser speckle images
NASA Astrophysics Data System (ADS)
Lertsakdadet, Ben; Yang, Bruce Y.; Dunn, Cody E.; Ponticorvo, Adrien; Crouzet, Christian; Bernal, Nicole; Durkin, Anthony J.; Choi, Bernard
2018-03-01
Laser speckle imaging (LSI) is a wide-field optical technique that enables superficial blood flow quantification. LSI is normally performed in a mounted configuration to decrease the likelihood of motion artifact. However, mounted LSI systems are cumbersome and difficult to transport quickly in a clinical setting for which portability is essential in providing bedside patient care. To address this issue, we created a handheld LSI device using scientific grade components. To account for motion artifact of the LSI device used in a handheld setup, we incorporated a fiducial marker (FM) into our imaging protocol and determined the difference between highest and lowest speckle contrast values for the FM within each data set (Kbest and Kworst). The difference between Kbest and Kworst in mounted and handheld setups was 8% and 52%, respectively, thereby reinforcing the need for motion artifact quantification. When using a threshold FM speckle contrast value (KFM) to identify a subset of images with an acceptable level of motion artifact, mounted and handheld LSI measurements of speckle contrast of a flow region (KFLOW) in in vitro flow phantom experiments differed by 8%. Without the use of the FM, mounted and handheld KFLOW values differed by 20%. To further validate our handheld LSI device, we compared mounted and handheld data from an in vivo porcine burn model of superficial and full thickness burns. The speckle contrast within the burn region (KBURN) of the mounted and handheld LSI data differed by <4 % when accounting for motion artifact using the FM, which is less than the speckle contrast difference between superficial and full thickness burns. Collectively, our results suggest the potential of handheld LSI with an FM as a suitable alternative to mounted LSI, especially in challenging clinical settings with space limitations such as the intensive care unit.
Miniaturized low-cost ion mobility spectrometer for fast detection of chemical warfare agents.
Zimmermann, Stefan; Barth, Sebastian; Baether, Wolfgang K M; Ringer, Joachim
2008-09-01
Ion mobility spectrometry (IMS) is a well-known method for detecting hazardous compounds in air. Typical applications are the detection of chemical warfare agents, highly toxic industrial compounds, explosives, and drugs of abuse. Detection limits in the low part per billion range, fast response times, and simple instrumentation make this technique more and more popular. In particular, there is an increasing demand for miniaturized low-cost IMS for hand-held devices and air monitoring of public areas by sensor networks. In this paper, we present a miniaturized aspiration condenser type ion mobility spectrometer for fast detection of chemical warfare agents. The device is easy to manufacture and allows single substance identification down to low part per billion-level concentrations within seconds. The improved separation power results from ion focusing by means of geometric constraints and fluid dynamics. A simple pattern recognition algorithm is used for the identification of trained substances in air. The device was tested at the German Armed Forces Scientific Institute for Protection Technologies-NBC-Protection. Different chemical warfare agents, such as sarin, tabun, soman, US-VX, sulfur mustard, nitrogen mustard, and lewisite were tested. The results are presented here.
Handheld Sensor for UXO Discrimination:
2006-06-01
between buried UXO and clutter. This project demonstrated the use of commercially available technology (Geonics EM61-HH handheld metal detector ) for...determine whether each target was UXO or clutter. The Geonics EM61-HH handheld metal detector is a pulsed electromagnetic induction (EMI) sensor. The...processing, the EM61-HH handheld metal detector can 2 be used in a cued identification mode to reliably discriminate between buried UXO and clutter
Bryk, Flavio Fernandes; Dos Reis, Amir Curcio; Fingerhut, Deborah; Araujo, Thomas; Schutzer, Marcela; Cury, Ricardo de Paula Leite; Duarte, Aires; Fukuda, Thiago Yukio
2016-05-01
The objective of this study was to evaluate whether women with knee osteoarthritis performing a rehabilitation programme consisting of low-load exercises combined with PVO exhibited the same results in changes in quadriceps strength, pain relief, and functional improvement when compared to women receiving a programme consisting of high-load exercises without PVO. Thirty-four women (mean age, 61 years) with a diagnosis of knee osteoarthritis were randomly assigned to a conventional or occlusion group. The women in the conventional group (n = 17) performed a 6-week quadriceps strengthening and stretching programme using a load around 70 % of the 1-repetition maximum (RM). The women in the occlusion group (n = 17) performed the same programme, however, only using a load around 30 % of the 1-RM, while PVO was induced. The PVO was achieved using a pressure cuff applied to the upper third of the thigh and inflated to 200 mmHg during the quadriceps exercise. An 11-point Numerical Pain Rating Scale (NPRS), the Lequesne questionnaire, the Timed-Up and Go (TUG) test, and muscle strength measurement using a hand-held dynamometer were used as outcome measures at baseline (pretreatment) and at the end of the 6-week of treatment. Pain, using the NPRS, was also assessed when performing the quadriceps exercises during the exercise sessions. At baseline, demographic, strength, pain, and functional assessment data were similar between groups. Patients from both the conventional and occlusion groups had a higher level of function (Lequesne and TUG test), less pain (NPRS), and higher quadriceps strength at the 6-week evaluation when compared to baseline (all P < 0.05). However, the between-group analysis showed no differences for all outcomes variables at posttreatment (n.s.). Patients in the occlusion group experienced less anterior knee discomfort during the treatment sessions than those in the high-load exercise group (P < 0.05). A rehabilitation programme that combined PVO to low-load exercise resulted in similar benefits in pain, function, and quadriceps strength than a programme using high-load conventional exercise in patients with knee osteoarthritis. However, the use of PVO combined with low-load exercise resulted in less anterior knee pain during the training sessions. I.
Kloos, Anne D; Fritz, Nora E; Kostyk, Sandra K; Young, Gregory S; Kegelmeyer, Deb A
2013-11-01
To investigate the feasibility, acceptability, and safety of a supervised video game exercise program administered via Dance Dance Revolution in individuals with Huntington's disease. A cross-over, controlled, single-blinded, six-week trial. Home-based. Eighteen ambulatory individuals with Huntington's disease (seven male, mean age 50.7 SD 14.7). Participants played the Dance Dance Revolution game with supervision and the handheld game without supervision for 45 minutes, two days per week for six weeks. Game play performance and adherence, participant perceptions of the game, safety (vital signs, adverse health changes), spatiotemporal gait measures, Four-Square Step Test, Tinetti Mobility Test, Activities-Specific Balance Confidence Scale, and World Health Organization Quality of Life - Bref, before and after each intervention. Most participants improved on game play, enjoyed playing the game, and wanted to continue playing after study completion. After playing Dance Dance Revolution, participants showed significant reductions in double support percentage (adjusted mean difference (95% confidence intervals): -2.54% (-4.75, -0.34) for forward walking and -4.18 (-6.89, -0.48) for backward walking) and those with less severe motor symptoms had reductions in heel-to-heel base of support during forward walking. The remaining measures were not significantly impacted by the intervention. Dance Dance Revolution appears to be a feasible, motivating, and safe exercise intervention for individuals with Huntington's disease.
Practical applications of hand-held computers in dermatology.
Goldblum, Orin M
2002-09-01
For physicians, hand-held computers are gaining popularity as point of care reference tools. The convergence of hand-held computers, the Internet, and wireless networks will enable these devices to assume more essential roles as mobile transmitters and receivers of digital medical Information. In addition to serving as portable medical reference sources, these devices can be Internet-enabled, allowing them to communicate over wireless wide and local area networks. With enhanced wireless connectivity, hand-held computers can be used at the point of patient care for charge capture, electronic prescribing, laboratory test ordering, laboratory result retrieval, web access, e-mail communication, and other clinical and administrative tasks. Physicians In virtually every medical specialty have begun using these devices in various ways. This review of hand-held computer use in dermatology illustrates practical examples of the many different ways hand-held computers can be effectively used by the practicing dermatologist.
Thioaptamer Diagnostic System (TDS)
NASA Technical Reports Server (NTRS)
Yang, Xianbin
2015-01-01
AM Biotechnologies, LLC, in partnership with Sandia National Laboratories, has developed a diagnostic device that quickly detects sampled biomarkers. The TDS quickly quantifies clinically relevant biomarkers using only microliters of a single sample. The system combines ambient-stable, long shelf-life affinity assays with handheld, microfluidic gel electrophoresis affinity assay quantification technology. The TDS is easy to use, operates in microgravity, and permits simultaneous quantification of 32 biomarkers. In Phase I of the project, the partners demonstrated that a thioaptamer assay used in the microfluidic instrument could quantify a specific biomarker in serum in the low nanomolar range. The team also identified novel affinity agents to bone-specific alkaline phosphatase (BAP) and demonstrated their ability to detect BAP with the microfluidic instrument. In Phase II, AM Biotech expanded the number of ambient affinity agents and demonstrated a TDS prototype. In the long term, the clinical version of the TDS will provide a robust, flight-tested diagnostic capability for space exploration missions.
Saz, Eylem Ulaş; Arikan, Ciğdem; Ozgenç, Funda; Duyu, Muhterem; Ozananar, Yeliz
2010-06-01
We aimed to identify the presence of ingested metallic foreign bodies with handheld metal detector in the pediatric population. All children (n=40) known or suspected to have ingested a MFB and who presented to the Emergency Department of the Children's Hospital of Ege University were prospectively ascertained. All patients underwent both radiographic evaluation and handheld metal detector scanning of the chest and abdomen on their presentation. In the present prospective study, we compared handheld metal detector scanning with plain radiography. The end point of the study compared metallic foreign body findings with handheld metal detector vs radiological findings during an eight-month period. Forty subjects with possible metallic foreign body ingestion were enrolled into the study. The principle investigator scanned all subjects. Disease was defined by the presence of a foreign body in the gastrointestinal tract on radiograph. Radiographically, 35 foreign bodies were found, and handheld metal detector revealed 31 of them. The sensitivity of handheld metal detector was 88.6% (95% confidence interval [CI]: 72.1%-96.5%), specificity 100% (95% CI: 61.8%-100%), positive predictive value (PPV) 100% (95% CI: 85.8%-100%), and negative predictive value 55.5% (95% CI: 34.3%-84.6%). Handheld metal detector revealed that 2 metallic foreign bodies (1 pushpin, 1 coin) were localized to the chest, which was confirmed by radiography, and urgent removal was performed with endoscopy. Handheld metal detector scanning is an accurate, inexpensive, radiation-free screening tool and should be used for evaluation of patients suspected of ingesting metallic foreign bodies.
Coping with Exercise-Induced Asthma in Sports.
ERIC Educational Resources Information Center
Katz, Roger M.
1987-01-01
This article reviews the history of research on exercise-induced asthma (EIA) and the pathophysiology of the condition, including its development and influencing factors. Four groups of drugs that are effective against EIA--theopyhlline, beta-adrenergic agents, cromolyn sodium, and anticholinergics--are discussed. (Author/CB)
Treatment options for the management of exercise-induced asthma and bronchoconstriction.
Millward, David T; Tanner, Lindsay G; Brown, Mark A
2010-12-01
Treatment for exercise-induced bronchospasm and exercise-induced asthma includes both pharmacologic and nonpharmacologic options. Pharmacologic agents that have been proven to be effective for treating these conditions include short- and long-acting β2-adrenoceptor agonists, mast cell-stabilizing agents, anticholinergics, leukotriene receptor antagonists, and inhaled corticosteroids (ICS). When selecting the most appropriate medication, factors to consider include the effectiveness of each, the duration of action, frequency of administration, potential side effects, and tolerance level. Long-acting β2-adrenoceptor agonists should not be used without ICS. Nonpharmacologic treatments include physical conditioning, incorporating a warm-up before and a cool-down period after exercise, performing nasal breathing, avoiding cold weather or environmental allergens, using a face mask or other aid to warm and humidify inhaled air, and modifying dietary intake. The data to support nonpharmacologic treatments are limited; however, they are routinely recommended because of the low risk associated with their use. This article highlights the advantages and limitations of each treatment option.
NASA Astrophysics Data System (ADS)
Deutsch, Erik R.; Haibach, Frederick G.; Mazurenko, Alexander
2012-06-01
The requirements for standoff detection of Explosives and CWA/TICs on surfaces in the battlefield are challenging because of the low detection limits. The variety of targets, backgrounds and interferences increase the challenges. Infrared absorption spectroscopy with traditional infrared detection technologies, incandescent sources that offer broad wavelength range but poor spectral intensity, are particularly challenged in standoff applications because most photons are lost to the target, background and the environment. Using a brighter source for active infrared detection e.g. a widely-tunable quantum cascade laser (QCL) source, provides sufficient spectral intensity to achieve the needed sensitivity and selectivity for explosives, CWAs, and TICs on surfaces. Specific detection of 1-10 μg/cm2 is achieved within seconds. CWAs, and TICs in vapor and aerosol form present a different challenge. Vapors and aerosols are present at low concentrations, so long pathlengths are required to achieve the desired sensitivity. The collimated output beam from the QCL simplifies multi-reflection cells for vapor detection while also enabling large standoff distances. Results obtained by the QCL system indicate that <1 ppm for vapors can be achieved with specificity in a measurement time of seconds, and the QCL system was successfully able to detect agents in the presence of interferents. QCLs provide additional capabilities for the dismounted warfighter. Given the relatively low power consumption, small package, and instant-on capability of the QCL, a handheld device can provide field teams with early detection of toxic agents and energetic materials in standoff, vapor, or aerosol form using a single technology and device which makes it attractive compared other technologies.
2016-04-01
AFCEC-CX-TY-TR-2016-0007 HANDHELD CHEM/ BIOSENSOR USING EXTREME CONFORMATIONAL CHANGES IN DESIGNED BINDING PROTEINS TO ENHANCE SURFACE PLASMON...Include area code) 03/24/2016 Abstract 08/14/2015--03/31/2016 Handheld chem/ biosensor using extreme conformational changes in designed binding...Baltimore, Maryland on 17-21 April 2016. We propose the development of a highly sensitive handheld chem/ biosensor device using a novel class of engineered
Texting while driving: is speech-based text entry less risky than handheld text entry?
He, J; Chaparro, A; Nguyen, B; Burge, R J; Crandall, J; Chaparro, B; Ni, R; Cao, S
2014-11-01
Research indicates that using a cell phone to talk or text while maneuvering a vehicle impairs driving performance. However, few published studies directly compare the distracting effects of texting using a hands-free (i.e., speech-based interface) versus handheld cell phone, which is an important issue for legislation, automotive interface design and driving safety training. This study compared the effect of speech-based versus handheld text entries on simulated driving performance by asking participants to perform a car following task while controlling the duration of a secondary text-entry task. Results showed that both speech-based and handheld text entries impaired driving performance relative to the drive-only condition by causing more variation in speed and lane position. Handheld text entry also increased the brake response time and increased variation in headway distance. Text entry using a speech-based cell phone was less detrimental to driving performance than handheld text entry. Nevertheless, the speech-based text entry task still significantly impaired driving compared to the drive-only condition. These results suggest that speech-based text entry disrupts driving, but reduces the level of performance interference compared to text entry with a handheld device. In addition, the difference in the distraction effect caused by speech-based and handheld text entry is not simply due to the difference in task duration. Copyright © 2014 Elsevier Ltd. All rights reserved.
Use of handheld computers in clinical practice: a systematic review.
Mickan, Sharon; Atherton, Helen; Roberts, Nia Wyn; Heneghan, Carl; Tilson, Julie K
2014-07-06
Many healthcare professionals use smartphones and tablets to inform patient care. Contemporary research suggests that handheld computers may support aspects of clinical diagnosis and management. This systematic review was designed to synthesise high quality evidence to answer the question; Does healthcare professionals' use of handheld computers improve their access to information and support clinical decision making at the point of care? A detailed search was conducted using Cochrane, MEDLINE, EMBASE, PsycINFO, Science and Social Science Citation Indices since 2001. Interventions promoting healthcare professionals seeking information or making clinical decisions using handheld computers were included. Classroom learning and the use of laptop computers were excluded. Two authors independently selected studies, assessed quality using the Cochrane Risk of Bias tool and extracted data. High levels of data heterogeneity negated statistical synthesis. Instead, evidence for effectiveness was summarised narratively, according to each study's aim for assessing the impact of handheld computer use. We included seven randomised trials investigating medical or nursing staffs' use of Personal Digital Assistants. Effectiveness was demonstrated across three distinct functions that emerged from the data: accessing information for clinical knowledge, adherence to guidelines and diagnostic decision making. When healthcare professionals used handheld computers to access clinical information, their knowledge improved significantly more than peers who used paper resources. When clinical guideline recommendations were presented on handheld computers, clinicians made significantly safer prescribing decisions and adhered more closely to recommendations than peers using paper resources. Finally, healthcare professionals made significantly more appropriate diagnostic decisions using clinical decision making tools on handheld computers compared to colleagues who did not have access to these tools. For these clinical decisions, the numbers need to test/screen were all less than 11. Healthcare professionals' use of handheld computers may improve their information seeking, adherence to guidelines and clinical decision making. Handheld computers can provide real time access to and analysis of clinical information. The integration of clinical decision support systems within handheld computers offers clinicians the highest level of synthesised evidence at the point of care. Future research is needed to replicate these early results and to identify beneficial clinical outcomes.
Use of handheld computers in clinical practice: a systematic review
2014-01-01
Background Many healthcare professionals use smartphones and tablets to inform patient care. Contemporary research suggests that handheld computers may support aspects of clinical diagnosis and management. This systematic review was designed to synthesise high quality evidence to answer the question; Does healthcare professionals’ use of handheld computers improve their access to information and support clinical decision making at the point of care? Methods A detailed search was conducted using Cochrane, MEDLINE, EMBASE, PsycINFO, Science and Social Science Citation Indices since 2001. Interventions promoting healthcare professionals seeking information or making clinical decisions using handheld computers were included. Classroom learning and the use of laptop computers were excluded. Two authors independently selected studies, assessed quality using the Cochrane Risk of Bias tool and extracted data. High levels of data heterogeneity negated statistical synthesis. Instead, evidence for effectiveness was summarised narratively, according to each study’s aim for assessing the impact of handheld computer use. Results We included seven randomised trials investigating medical or nursing staffs’ use of Personal Digital Assistants. Effectiveness was demonstrated across three distinct functions that emerged from the data: accessing information for clinical knowledge, adherence to guidelines and diagnostic decision making. When healthcare professionals used handheld computers to access clinical information, their knowledge improved significantly more than peers who used paper resources. When clinical guideline recommendations were presented on handheld computers, clinicians made significantly safer prescribing decisions and adhered more closely to recommendations than peers using paper resources. Finally, healthcare professionals made significantly more appropriate diagnostic decisions using clinical decision making tools on handheld computers compared to colleagues who did not have access to these tools. For these clinical decisions, the numbers need to test/screen were all less than 11. Conclusion Healthcare professionals’ use of handheld computers may improve their information seeking, adherence to guidelines and clinical decision making. Handheld computers can provide real time access to and analysis of clinical information. The integration of clinical decision support systems within handheld computers offers clinicians the highest level of synthesised evidence at the point of care. Future research is needed to replicate these early results and to identify beneficial clinical outcomes. PMID:24998515
Agent-Based Modeling of Growth Processes
ERIC Educational Resources Information Center
Abraham, Ralph
2014-01-01
Growth processes abound in nature, and are frequently the target of modeling exercises in the sciences. In this article we illustrate an agent-based approach to modeling, in the case of a single example from the social sciences: bullying.
Correcting for motion artifact in handheld laser speckle images.
Lertsakdadet, Ben; Yang, Bruce Y; Dunn, Cody E; Ponticorvo, Adrien; Crouzet, Christian; Bernal, Nicole; Durkin, Anthony J; Choi, Bernard
2018-03-01
Laser speckle imaging (LSI) is a wide-field optical technique that enables superficial blood flow quantification. LSI is normally performed in a mounted configuration to decrease the likelihood of motion artifact. However, mounted LSI systems are cumbersome and difficult to transport quickly in a clinical setting for which portability is essential in providing bedside patient care. To address this issue, we created a handheld LSI device using scientific grade components. To account for motion artifact of the LSI device used in a handheld setup, we incorporated a fiducial marker (FM) into our imaging protocol and determined the difference between highest and lowest speckle contrast values for the FM within each data set (Kbest and Kworst). The difference between Kbest and Kworst in mounted and handheld setups was 8% and 52%, respectively, thereby reinforcing the need for motion artifact quantification. When using a threshold FM speckle contrast value (KFM) to identify a subset of images with an acceptable level of motion artifact, mounted and handheld LSI measurements of speckle contrast of a flow region (KFLOW) in in vitro flow phantom experiments differed by 8%. Without the use of the FM, mounted and handheld KFLOW values differed by 20%. To further validate our handheld LSI device, we compared mounted and handheld data from an in vivo porcine burn model of superficial and full thickness burns. The speckle contrast within the burn region (KBURN) of the mounted and handheld LSI data differed by <4 % when accounting for motion artifact using the FM, which is less than the speckle contrast difference between superficial and full thickness burns. Collectively, our results suggest the potential of handheld LSI with an FM as a suitable alternative to mounted LSI, especially in challenging clinical settings with space limitations such as the intensive care unit. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Spears, Karen E; Kim, Hyunsook; Behall, Kay M; Conway, Joan M
2009-05-01
To compare standardized prediction equations to a hand-held indirect calorimeter in estimating resting energy and total energy requirements in overweight women. Resting energy expenditure (REE) was measured by hand-held indirect calorimeter and calculated by prediction equations Harris-Benedict, Mifflin-St Jeor, World Health Organization/Food and Agriculture Organization/United Nations University (WHO), and Dietary Reference Intakes (DRI). Physical activity level, assessed by questionnaire, was used to estimate total energy expenditure (TEE). Subjects (n=39) were female nonsmokers older than 25 years of age with body mass index more than 25. Repeated measures analysis of variance, Bland-Altman plot, and fitted regression line of difference. A difference within +/-10% of two methods indicated agreement. Significant proportional bias was present between hand-held indirect calorimeter and prediction equations for REE and TEE (P<0.01); prediction equations overestimated at lower values and underestimated at higher values. Mean differences (+/-standard error) for REE and TEE between hand-held indirect calorimeter and Harris-Benedict were -5.98+/-46.7 kcal/day (P=0.90) and 21.40+/-75.7 kcal/day (P=0.78); between hand-held indirect calorimeter and Mifflin-St Jeor were 69.93+/-46.7 kcal/day (P=0.14) and 116.44+/-75.9 kcal/day (P=0.13); between hand-held indirect calorimeter and WHO were -22.03+/-48.4 kcal/day (P=0.65) and -15.8+/-77.9 kcal/day (P=0.84); and between hand-held indirect calorimeter and DRI were 39.65+/-47.4 kcal/day (P=0.41) and 56.36+/-85.5 kcal/day (P=0.51). Less than 50% of predictive equation values were within +/-10% of hand-held indirect calorimeter values, indicating poor agreement. A significant discrepancy between predicted and measured energy expenditure was observed. Further evaluation of hand-held indirect calorimeter research screening is needed.
Handheld, point-of-care laser speckle imaging
Farraro, Ryan; Fathi, Omid; Choi, Bernard
2016-01-01
Abstract. Laser speckle imaging (LSI) enables measurement of relative changes in blood flow in biological tissues. We postulate that a point-of-care form factor will lower barriers to routine clinical use of LSI. Here, we describe a first-generation handheld LSI device based on a tablet computer. The coefficient of variation of speckle contrast was <2% after averaging imaging data collected over an acquisition period of 5.3 s. With a single, experienced user, handheld motion artifacts had a negligible effect on data collection. With operation by multiple users, we did not identify any significant difference (p>0.05) between the measured speckle contrast values using either a handheld or mounted configuration. In vivo data collected during occlusion experiments demonstrate that a handheld LSI is capable of both quantitative and qualitative assessment of changes in blood flow. Finally, as a practical application of handheld LSI, we collected data from a 53-day-old neonate with confirmed compromised blood flow in the hand. We readily identified with LSI a region of diminished blood flow in the thumb of the affected hand. Our data collectively suggest that handheld LSI is a promising technique to enable clinicians to obtain point-of-care measurements of blood flow. PMID:27579578
Using medical knowledge sources on handheld computers--a qualitative study among junior doctors.
Axelson, Christian; Wårdh, Inger; Strender, Lars-Erik; Nilsson, Gunnar
2007-09-01
The emergence of mobile computing could have an impact on how junior doctors learn. To exploit this opportunity it is essential to understand their information seeking process. To explore junior doctors' experiences of using medical knowledge sources on handheld computers. Interviews with five Swedish junior doctors. A qualitative manifest content analysis of a focus group interview followed by a qualitative latent content analysis of two individual interviews. A focus group interview showed that users were satisfied with access to handheld medical knowledge sources, but there was concern about contents, reliability and device dependency. Four categories emerged from individual interviews: (1) A feeling of uncertainty about using handheld technology in medical care; (2) A sense of security that handhelds can provide; (3) A need for contents to be personalized; (4) A degree of adaptability to make the handheld a versatile information tool. A theme was established to link the four categories together, as expressed in the Conclusion section. Junior doctors' experiences of using medical knowledge sources on handheld computers shed light on the need to decrease uncertainty about clinical decisions during medical internship, and to find ways to influence the level of self-confidence in the junior doctor's process of decision-making.
Handheld, point-of-care laser speckle imaging
NASA Astrophysics Data System (ADS)
Farraro, Ryan; Fathi, Omid; Choi, Bernard
2016-09-01
Laser speckle imaging (LSI) enables measurement of relative changes in blood flow in biological tissues. We postulate that a point-of-care form factor will lower barriers to routine clinical use of LSI. Here, we describe a first-generation handheld LSI device based on a tablet computer. The coefficient of variation of speckle contrast was <2% after averaging imaging data collected over an acquisition period of 5.3 s. With a single, experienced user, handheld motion artifacts had a negligible effect on data collection. With operation by multiple users, we did not identify any significant difference (p>0.05) between the measured speckle contrast values using either a handheld or mounted configuration. In vivo data collected during occlusion experiments demonstrate that a handheld LSI is capable of both quantitative and qualitative assessment of changes in blood flow. Finally, as a practical application of handheld LSI, we collected data from a 53-day-old neonate with confirmed compromised blood flow in the hand. We readily identified with LSI a region of diminished blood flow in the thumb of the affected hand. Our data collectively suggest that handheld LSI is a promising technique to enable clinicians to obtain point-of-care measurements of blood flow.
46 CFR 160.036-3 - Materials, workmanship, construction and performance requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket... performance requirements. (a) Materials. The materials used in handheld rocket-propelled parachute red flare... protected against corrosion. (b) Workmanship. Handheld rocket-propelled parachute red flare distress signals...
46 CFR 160.036-3 - Materials, workmanship, construction and performance requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
...) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket... performance requirements. (a) Materials. The materials used in handheld rocket-propelled parachute red flare... protected against corrosion. (b) Workmanship. Handheld rocket-propelled parachute red flare distress signals...
46 CFR 160.036-3 - Materials, workmanship, construction and performance requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket... performance requirements. (a) Materials. The materials used in handheld rocket-propelled parachute red flare... protected against corrosion. (b) Workmanship. Handheld rocket-propelled parachute red flare distress signals...
46 CFR 160.036-3 - Materials, workmanship, construction and performance requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
...) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket... performance requirements. (a) Materials. The materials used in handheld rocket-propelled parachute red flare... protected against corrosion. (b) Workmanship. Handheld rocket-propelled parachute red flare distress signals...
46 CFR 160.036-3 - Materials, workmanship, construction and performance requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket... performance requirements. (a) Materials. The materials used in handheld rocket-propelled parachute red flare... protected against corrosion. (b) Workmanship. Handheld rocket-propelled parachute red flare distress signals...
2016-09-01
EVALUATION OF U.S. COMMERCIAL-OFF-THE-SHELF HAND-HELD ASSAYS TO DETECT OPIATE PAIN RELIEVER COMPOUNDS IN...Commercial-Off-the-Shelf Hand-Held Assays to Detect Opiate Pain Reliever Compounds in Multiple Biofluids 5a. CONTRACT NUMBER 5b. GRANT NUMBER R...study, we evaluated the potential for several U.S. commercial-off-the-shelf (COTS) hand-held assays (HHAs) to detect members of the opiate pain reliever
Field testing of hand-held infrared thermography, phase II TPF-5(247) : final report.
DOT National Transportation Integrated Search
2016-05-01
This report is the second of two volumes that document results from the pooled fund study TPF-5 (247), Development of : Handheld Infrared Thermography, Phase II. The interim report (volume I) studied the implementation of handheld thermography : by p...
Code of Federal Regulations, 2012 CFR
2012-10-01
...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-5 Marking. (a) General. Each hand-held rocket-propelled parachute red flare distress signal shall be legibly marked or labeled as follows: (Company brand or style designation) Hand-Held Rocket...
Code of Federal Regulations, 2011 CFR
2011-10-01
...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-5 Marking. (a) General. Each hand-held rocket-propelled parachute red flare distress signal shall be legibly marked or labeled as follows: (Company brand or style designation) Hand-Held Rocket...
Code of Federal Regulations, 2013 CFR
2013-10-01
...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-5 Marking. (a) General. Each hand-held rocket-propelled parachute red flare distress signal shall be legibly marked or labeled as follows: (Company brand or style designation) Hand-Held Rocket...
Code of Federal Regulations, 2014 CFR
2014-10-01
...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-5 Marking. (a) General. Each hand-held rocket-propelled parachute red flare distress signal shall be legibly marked or labeled as follows: (Company brand or style designation) Hand-Held Rocket...
Code of Federal Regulations, 2010 CFR
2010-10-01
...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-5 Marking. (a) General. Each hand-held rocket-propelled parachute red flare distress signal shall be legibly marked or labeled as follows: (Company brand or style designation) Hand-Held Rocket...
Harmelink, Karen E M; Zeegers, A V C M; Tönis, Thijs M; Hullegie, Wim; Nijhuis-van der Sanden, Maria W G; Staal, J Bart
2017-07-05
There is consistent evidence that supervised programs are not superior to home-based programs after total knee arthroplasty (TKA), especially in patients without complications. Home-based exercise programs are effective, but we hypothesize that their effectiveness can be improved by increasing the adherence to physical therapy advice to reach an adequate exercise level during the program and thereafter. Our hypothesis is that an activity coaching system (accelerometer-based activity sensor), alongside a home-based exercise program, will increase adherence to exercises and the activity level, thereby improving physical functioning and recovery. The objective of this study is to determine the effectiveness of an activity coaching system in addition to a home-based exercise program after a TKA compared to only the home-based exercise program with physical functioning as outcome. This study is a single-blind randomized controlled trial. Both the intervention (n = 55) and the control group (n = 55) receive a two-week home-based exercise program, and the intervention group receives an additional activity coaching system. This is a hand-held electronic device together with an app on a smartphone providing information and advice on exercise behavior during the day. The primary outcome is physical functioning, measured with the Timed Up and Go test (TUG) after two weeks, six weeks and three months. Secondary outcomes are 1) adherence to the activity level (activity diary); 2) physical functioning, measured with the 2-Minute Walk Test (2MWT) and the Knee Osteoarthritis Outcome Score; 3) quality of life (SF-36); 4) healthcare use up to one year postoperatively and 5) cost-effectiveness. Data are collected preoperatively, three days, two and six weeks, three months and one year postoperatively. The strengths of the study are the use of both performance-based tests and self-reported questionnaires and the personalized tailored program after TKA given by specialized physical therapists. Its weakness is the lack of blinding of the participants to treatment allocation. Outcomes are generalizable to uncomplicated patients as defined in the inclusion criteria. The trial is registered in the Dutch Trial Register ( www.trialregister.nl , NTR 5109) (March 22, 2015).
Incentive spirometry decreases respiratory complications following major abdominal surgery.
Westwood, K; Griffin, M; Roberts, K; Williams, M; Yoong, K; Digger, T
2007-12-01
Pulmonary complications are the leading cause of morbidity and mortality following major abdominal surgery. Chest physiotherapy aims to decrease the likelihood of these complications and hasten recovery. Exercises aimed at maximising inspiratory effort are the most beneficial for the patients. The incentive spirometer is a handheld device that patients use to achieve effective inspiration. In a nonrandomised pilot study of 263 patients we have found that the addition of the incentive spirometer, as part of an intensive post-operative physiotherapy programme, decreased the occurrence of pulmonary complications (6 vs 17%, p = 0.01) and length of stay on the surgical high dependency unit (3.1 vs 4 days p = 0.03). The two groups were comparable when age, sex, smoking history, the need for emergency surgery and post-operative analgesia were compared.
Phone use while driving: results from an observational survey.
Wundersitz, L N
2014-01-01
The aim of this study was to quantify the level of handheld phone use when driving in South Australia. The study also sought to investigate any driver, site, and vehicle characteristics associated with handheld phone use to inform countermeasure development and publicity campaigns. An on-road observational survey of handheld phone use was undertaken as part of a larger restraint use survey. The survey was conducted at 61 sites in metropolitan Adelaide and rural regions within South Australia on weekdays and a weekend in 2009. A total of 64 (0.6%) of the 11,524 drivers observed during the survey were using handheld phones. Handheld phone usage rates ranged from 0.8 percent in metropolitan Adelaide to 0.3 percent in the rural region of The Riverland. Of all driver, site, and vehicle characteristics examined, the only statistically significant difference in handheld phone usage was for the number of vehicle occupants. The odds of a driver using a handheld phone while traveling alone was over 4 times higher than for a driver traveling with passengers. The level of handheld phone use among drivers in South Australia appears to be low relative to other jurisdictions. The level of enforcement activity and severity of penalties do not offer a clear explanation for the higher levels of compliance with phone laws. Given the rate of increase in phone technology, it is important to conduct regular roadside surveys of phone use among drivers to monitor trends in usage over time.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-28
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-697] In the Matter of Certain Authentication Systems, Including Software and Handheld Electronic Devices; Notice of Commission Decision Not to... importation of certain authentication systems, including software and handheld electronic devices, by reason...
Wireless Handhelds to Support Clinical Nursing Practicum
ERIC Educational Resources Information Center
Wu, Cheng-Chih; Lai, Chin-Yuan
2009-01-01
This paper reports our implementation and evaluation of a wireless handheld learning environment used to support a clinical nursing practicum course. The learning environment was designed so that nursing students could use handhelds for recording information, organizing ideas, assessing patients, and also for interaction and collaboration with…
NASA Technical Reports Server (NTRS)
Wunsch, S. A.; Muller-Delp, J.; Delp, M. D.
2000-01-01
At the onset of dynamic exercise, muscle blood flow increases within 1-2 s. It has been postulated that local vasodilatory agents produced by the vascular endothelium or the muscle itself contribute to this response. We hypothesized that only vasodilators that act directly on the vascular smooth muscle could produce vasodilation of skeletal muscle arterioles in <2 s. To test this hypothesis, we determined the time course of the vasodilatory response of isolated skeletal muscle arterioles to direct application of potassium chloride, adenosine, acetylcholine, and sodium nitroprusside. Soleus and gastrocnemius muscles were dissected from the hindlimbs of male Sprague-Dawley rats. First-order arterioles (100-200 microm) were isolated, cannulated on micropipettes, and pressurized to 60 cmH(2)O in an organ bath. Vasodilatory agents were added directly to the bath, and diameter responses of the arterioles were recorded in real time on a videotape recorder. Frame-by-frame analysis of the diameter responses indicated that none of the vasodilator agents tested produced significant diameter increases in <4 s in either soleus or gastrocnemius muscle arterioles. These results indicate that, although these local vasodilators produce significant vasodilation of skeletal muscle resistance arterioles, these responses are not rapid enough (within 1-2 s) to contribute to the initiation of the exercise hyperemic response at the onset of dynamic exercise.
2004-12-01
avantage comme Brucella spp par ex. De plus, chaque ELISA d’agent devrait &tre test~e avec un agent vivant pour confirmer la sensibilit6 du biotest aux...materiaux vivants . A plus long terme, i1 serait souhaitable dtudier des solutions de rechange qui seraient plus sensibles aux techniques
FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D
NASA Technical Reports Server (NTRS)
Bruno, John G.
2013-01-01
Astronauts lose 1.0 to 1.5% of their bone mass per month on long-duration spaceflights. NASA wishes to monitor the bone loss onboard spacecraft to develop nutritional and exercise countermeasures, and make adjustments during long space missions. On Earth, the same technology could be used to monitor osteoporosis and its therapy. Aptamers bind to targets against which they are developed, much like antibodies. However, aptamers do not require animal hosts or cell culture and are therefore easier, faster, and less expensive to produce. In addition, aptamers sometimes exhibit greater affinity and specificity vs. comparable antibodies. In this work, fluorescent dyes and quenchers were added to the aptamers to enable pushbutton, one-step, bind-and-detect fluorescence resonance energy transfer (FRET) assays or tests that can be freeze-dried, rehydrated with body fluids, and used to quantitate bone loss of vitamin D levels with a handheld fluorometer in the spacecraft environment. This work generated specific, rapid, one-step FRET assays for the bone loss marker C-telopeptide (CTx) when extracted from urine, creatinine from urine, and vitamin D congeners in diluted serum. The assays were quantified in nanograms/mL using a handheld fluorometer connected to a laptop computer to convert the raw fluorescence values into concentrations of each analyte according to linear standard curves. DNA aptamers were selected and amplified for several rounds against a 26- amino acid form of CTx, creatinine, and vitamin D. The commonalities between loop structures were studied, and several common loop structures were converted into aptamer beacons with a fluorophore and quencher on each end. In theory, when the aptamer beacon binds its cognate target (CTx bone peptide, creatinine, or vitamin D), it is forced open and no longer quenched, so it gives off fluorescent light (when excited) in proportion to the amount of target present in a sample. This proportional increase in fluorescence is called a "lights on" FRET response. The vitamin D aptamer beacon gives a "lights off" or inversely proportional fluorescence response to the amount of vitamin D present in diluted serum. These FRET-aptamer assays are rapid (<30 minutes), sensitive (low ng/mL detection limits), and quite easy to carry out (add sample, mix, and detect in the handheld reader). Benefits include the speed of the assays as well as the small amount of space taken up by the handheld reader and cuvette assays. The aptamer DNA sequences represent novel additional features of the existing (patent-pending) FRET-aptamer assay platform.
An Investigation of Game-Embedded Handheld Devices to Enhance English Learning
ERIC Educational Resources Information Center
Hung, Hui-Chun; Young, Shelley Shwu-Ching
2015-01-01
This study proposed and implemented a system combining the advantages of both educational games and wireless handheld technology to promote the interactive English learning in the classroom setting. An interactive English vocabulary acquisition board game was designed with the system being implemented on handheld devices. Thirty sixth-grade…
30 CFR 56.14116 - Hand-held power tools.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...
30 CFR 56.14116 - Hand-held power tools.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...
30 CFR 56.14116 - Hand-held power tools.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...
30 CFR 57.14116 - Hand-held power tools.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...
30 CFR 56.14116 - Hand-held power tools.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...
30 CFR 57.14116 - Hand-held power tools.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...
30 CFR 57.14116 - Hand-held power tools.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...
30 CFR 56.14116 - Hand-held power tools.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...
30 CFR 57.14116 - Hand-held power tools.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...
30 CFR 57.14116 - Hand-held power tools.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...
The transforming effect of handheld computers on nursing practice.
Thompson, Brent W
2005-01-01
Handheld computers have the power to transform nursing care. The roots of this power are the shift to decentralization of communication, electronic health records, and nurses' greater need for information at the point of care. This article discusses the effects of handheld resources, calculators, databases, electronic health records, and communication devices on nursing practice. The US government has articulated the necessity of implementing the use of handheld computers in healthcare. Nurse administrators need to encourage and promote the diffusion of this technology, which can reduce costs and improve care.
Kearney, N; Kidd, L; Miller, M; Sage, M; Khorrami, J; McGee, M; Cassidy, J; Niven, K; Gray, P
2006-07-01
Recent changes in cancer service provision mean that many patients spend a limited time in hospital and therefore experience and must cope with and manage treatment-related side effects at home. Information technology can provide innovative solutions in promoting patient care through information provision, enhancing communication, monitoring treatment-related side effects and promoting self-care. The aim of this feasibility study was to evaluate the acceptability of using handheld computers as a symptom assessment and management tool for patients receiving chemotherapy for cancer. A convenience sample of patients (n = 18) and health professionals (n = 9) at one Scottish cancer centre was recruited. Patients used the handheld computer to record and send daily symptom reports to the cancer centre and receive instant, tailored symptom management advice during two treatment cycles. Both patients' and health professionals' perceptions of the handheld computer system were evaluated at baseline and at the end of the project. Patients believed the handheld computer had improved their symptom management and felt comfortable in using it. The health professionals also found the handheld computer to be helpful in assessing and managing patients' symptoms. This project suggests that a handheld-computer-based symptom management tool is feasible and acceptable to both patients and health professionals in complementing the care of patients receiving chemotherapy.
Stray-Gundersen, James; Parsons, Dora Beth; Thompson, Jeffrey R.
2016-01-01
Patients treated with hemodialysis develop severely reduced functional capacity, which can be partially ameliorated by correcting anemia and through exercise training. In this study, we determined perturbations of an erythroid-stimulating agent and exercise training to examine if and where limitation to oxygen transport exists in patients on hemodialysis. Twenty-seven patients on hemodialysis completed a crossover study consisting of two exercise training phases at two hematocrit (Hct) values: 30% (anemic) and 42% (physiologic; normalized by treatment with erythroid-stimulating agent). To determine primary outcome measures of peak power and oxygen consumption (VO2) and secondary measures related to components of oxygen transport and utilization, all patients underwent numerous tests at five time points: baseline, untrained at Hct of 30%, after training at Hct of 30%, untrained at Hct of 42%, and after training at Hct of 42%. Hct normalization, exercise training, or the combination thereof significantly improved peak power and VO2 relative to values in the untrained anemic phase. Hct normalization increased peak arterial oxygen and arteriovenous oxygen difference, whereas exercise training improved cardiac output, citrate synthase activity, and peak tissue diffusing capacity. However, although the increase in arterial oxygen observed in the combination phase reached a value similar to that in healthy sedentary controls, the increase in peak arteriovenous oxygen difference did not. Muscle biopsy specimens showed markedly thickened endothelium and electron–dense interstitial deposits. In conclusion, exercise and Hct normalization had positive effects but failed to normalize exercise capacity in patients on hemodialysis. This effect may be caused by abnormalities identified within skeletal muscle. PMID:27153927
Template-based education toolkit for mobile platforms
NASA Astrophysics Data System (ADS)
Golagani, Santosh Chandana; Esfahanian, Moosa; Akopian, David
2012-02-01
Nowadays mobile phones are the most widely used portable devices which evolve very fast adding new features and improving user experiences. The latest generation of hand-held devices called smartphones is equipped with superior memory, cameras and rich multimedia features, empowering people to use their mobile phones not only as a communication tool but also for entertainment purposes. With many young students showing interest in learning mobile application development one should introduce novel learning methods which may adapt to fast technology changes and introduce students to application development. Mobile phones become a common device, and engineering community incorporates phones in various solutions. Overcoming the limitations of conventional undergraduate electrical engineering (EE) education this paper explores the concept of template-based based education in mobile phone programming. The concept is based on developing small exercise templates which students can manipulate and revise for quick hands-on introduction to the application development and integration. Android platform is used as a popular open source environment for application development. The exercises relate to image processing topics typically studied by many students. The goal is to enable conventional course enhancements by incorporating in them short hands-on learning modules.
Ariel, Barak; Bland, Matthew; Sutherland, Alex
2017-01-01
Supplementing local police forces is a burgeoning multibillion-dollar private security industry. Millions of formal surveillance agents in public settings are tasked to act as preventative guardians, as their high visibility presence is hypothesized to create a deterrent threat to potential offenders. Yet, rigorous evidence is lacking. We randomly assigned all train stations in the South West of England that experienced crime into treatment and controls conditions over a six-month period. Treatment consisted of directed patrol by uniformed, unarmed security agents. Hand-held trackers on every agent yielded precise measurements of all patrol time in the stations. Count-based regression models, estimated marginal means and odds-ratios are used to assess the effect of these patrols on crimes reported to the police by victims, as well as new crimes detected by police officers. Outcomes are measured at both specified target locations to which security guards were instructed to attend, as well as at the entire station complexes. Analyses show that 41% more patrol visits and 29% more minutes spent by security agents at treatment compared to control stations led to a significant 16% reduction in victim-generated crimes at the entirety of the stations' complexes, with a 49% increase in police-generated detections at the target locations. The findings illustrate the efficacy of private policing for crime prevention theory.
Panidis, Dimitrios; Tziomalos, Konstantinos; Papadakis, Efstathios; Vosnakis, Christos; Chatzis, Panagiotis; Katsikis, Ilias
2013-12-01
Obesity is frequently present in patients with polycystic ovary syndrome (PCOS) and plays an important role in the pathogenesis of the metabolic, endocrine, and reproductive abnormalities associated with this syndrome. We aimed to summarize the effects of lifestyle changes and anti-obesity pharmacotherapy in patients with PCOS. We reviewed the literature regarding the effects of lifestyle changes and anti-obesity agents on the metabolic and endocrine abnormalities of PCOS. Lifestyle changes, including diet, exercise, and behavioral modification, appear to improve the metabolic and reproductive abnormalities of overweight and obese patients with PCOS. Therefore, lifestyle changes appear to represent the first-line management for all overweight and obese patients with PCOS. However, the optimal composition of diet and the optimal type of exercise in these patients are unknown. Anti-obesity agents that have been studied in PCOS include orlistat, sibutramine, and rimonabant. However, the latter two agents have been withdrawn from the market because of side effects. Long-term studies with orlistat in overweight and obese diabetic patients showed greater weight loss and metabolic and cardiovascular benefits than those achieved with lifestyle changes alone. However, there are limited data on the efficacy of orlistat in women with PCOS. In conclusion, lifestyle changes (diet, exercise and behavioral modification), particularly when combined with anti-obesity agents, exert beneficial effects on the endocrine abnormalities of obese patients with PCOS and improve metabolic parameters.
Handheld Technology Acceptance in Radiologic Science Education and Training Programs
ERIC Educational Resources Information Center
Powers, Kevin Jay
2012-01-01
The purpose of this study was to explore the behavioral intention of directors of educational programs in the radiologic sciences to adopt handheld devices to aid in managing student clinical data. Handheld devices were described to participants as a technology representing a class of mobile electronic devices including, but not limited to,…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-23
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-706] In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld Devices and Battery Packs: Notice of Commission... handheld devices and battery packs by reason of infringement of certain claims of U.S. Patent Nos. 5,319...
Envisioning the Handheld-Centric Classroom
ERIC Educational Resources Information Center
Norris, Cathleen; Soloway, Elliot
2004-01-01
While appropriate as an initial focus, it is time that the educational community move beyond an emphasis on 1:1 computing (each child having his/her own personal computer) to a vision of a handheld-centric classroom, where each child not only has his/her own personal, handheld computer, but also has access to networked PCs, probeware, digital…
Handheld Computers: A Boon for Principals
ERIC Educational Resources Information Center
Brazell, Wayne
2005-01-01
As I reflect on my many years as an elementary school principal, I realize how much more effective I would have been if I had owned a wireless handheld computer. This relatively new technology can provide considerable assistance to today?s principals and recent advancements have increased its functions and capacity. Handheld computers are…
Students Using Handheld Computers to Learn Collaboratively in a First Grade Classroom
ERIC Educational Resources Information Center
Fritz, Megan Lynne
2005-01-01
This ethnographic study investigated how first grade students used handheld computers to learn in collaboration with others throughout the learning process. This research focused specifically on how the use of handheld computers impacts students' learning outcomes and relates to technology standards. A qualitative methodology was used to capture…
A Cognitive Style Perspective to Handheld Devices: Customization vs. Personalization
ERIC Educational Resources Information Center
Hsieh, Chen-Wei; Chen, Sherry Y.
2016-01-01
Handheld devices are widely applied to support open and distributed learning, where students are diverse. On the other hand, customization and personalization can be applied to accommodate students' diversities. However, paucity of research compares the effects of customization and personalization in the context of handheld devices. To this end, a…
Are Handheld Computers Dependable? A New Data Collection System for Classroom-Based Observations
ERIC Educational Resources Information Center
Adiguzel, Tufan; Vannest, Kimberly J.; Parker, Richard I.
2009-01-01
Very little research exists on the dependability of handheld computers used in public school classrooms. This study addresses four dependability criteria--reliability, maintainability, availability, and safety--to evaluate a data collection tool on a handheld computer. Data were collected from five sources: (1) time-use estimations by 19 special…
An ergonomic handheld ultrasound probe providing contact forces and pose information.
Yohan Noh; Housden, R James; Gomez, Alberto; Knight, Caroline; Garcia, Francesca; Hongbin Liu; Razavi, Reza; Rhode, Kawal; Althoefer, Kaspar
2015-08-01
This paper presents a handheld ultrasound probe which is integrated with sensors to measure force and pose (position/orientation) information. Using an integrated probe like this, one can relate ultrasound images to spatial location and create 3D ultrasound maps. The handheld device can be used by sonographers and also easily be integrated with robot arms for automated sonography. The handheld device is ergonomically designed; rapid attachment and removal of the ultrasound transducer itself is possible using easy-to-operate clip mechanisms. A cable locking mechanism reduces the impact that gravitational and other external forces have (originating from data and power supply cables connected to the probe) on our measurements. Gravitational errors introduced by the housing of the probe are compensated for using knowledge of the housing geometry and the integrated pose sensor that provides us with accurate orientation information. In this paper, we describe the handheld probe with its integrated force/pose sensors and our approach to gravity compensation. We carried out a set of experiments to verify the feasibility of our approach to obtain accurate spatial information of the handheld probe.
Tzeng, Shih-Yu; Guo, Jean-Yan; Yang, Chao-Chun; Hsu, Chao-Kai; Huang, Hung Ji; Chou, Shih-Jie; Hwang, Chi-Hung; Tseng, Sheng-Hao
2016-01-01
Diffuse reflectance spectroscopy (DRS) has been utilized to study biological tissues for a variety of applications. However, many DRS systems are not designed for handheld use and/or relatively expensive which limit the extensive clinical use of this technique. In this paper, we report a handheld, low-cost DRS system consisting of a light source, optical switch, and a spectrometer, that can precisely quantify the optical properties of tissue samples in the clinical setting. The handheld DRS system was employed to determine the skin chromophore concentrations, absorption and scattering properties of 11 patients with psoriasis. The measurement results were compared to the clinical severity of psoriasis as evaluated by dermatologist using PASI (Psoriasis Area and Severity Index) scores. Our statistical analyses indicated that the handheld DRS system could be a useful non-invasive tool for objective evaluation of the severity of psoriasis. It is expected that the handheld system can be used for the objective evaluation and monitoring of various skin diseases such as keloid and psoriasis. PMID:26977366
Hand-held radiometry: A set of notes developed for use at the Workshop of Hand-held radiometry
NASA Technical Reports Server (NTRS)
Jackson, R. D.; Pinter, P. J., Jr.; Reginato, R. J.; Idso, S. B. (Principal Investigator)
1980-01-01
A set of notes was developed to aid the beginner in hand-held radiometry. The electromagnetic spectrum is reviewed, and pertinent terms are defined. View areas of multiband radiometers are developed to show the areas of coincidence of adjacent bands. The amounts of plant cover seen by radiometers having different fields of view are described. Vegetation indices are derived and discussed. Response functions of several radiometers are shown and applied to spectrometer data taken over 12 wheat plots, to provide a comparison of instruments and bands within and among instruments. The calculation of solar time is reviewed and applied to the calculation of the local time of LANDSAT satellite overpasses for any particular location in the Northern Hemisphere. The use and misuse of hand-held infrared thermometers are discussed, and a procedure for photographic determination of plant cover is described. Some suggestions are offered concerning procedures to be followed when collecting hand-held spectral and thermal data. A list of references pertinent to hand-held radiometry is included.
32 CFR 151.5 - Reports on the exercise of foreign criminal jurisdiction.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 32 National Defense 1 2014-07-01 2014-07-01 false Reports on the exercise of foreign criminal jurisdiction. 151.5 Section 151.5 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE.... The Department of the Army is designated as executive agent within the Department of Defense for...
32 CFR 151.5 - Reports on the exercise of foreign criminal jurisdiction.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 32 National Defense 1 2012-07-01 2012-07-01 false Reports on the exercise of foreign criminal jurisdiction. 151.5 Section 151.5 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE.... The Department of the Army is designated as executive agent within the Department of Defense for...
32 CFR 151.5 - Reports on the exercise of foreign criminal jurisdiction.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 1 2010-07-01 2010-07-01 false Reports on the exercise of foreign criminal jurisdiction. 151.5 Section 151.5 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE.... The Department of the Army is designated as executive agent within the Department of Defense for...
32 CFR 151.5 - Reports on the exercise of foreign criminal jurisdiction.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 32 National Defense 1 2013-07-01 2013-07-01 false Reports on the exercise of foreign criminal jurisdiction. 151.5 Section 151.5 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE.... The Department of the Army is designated as executive agent within the Department of Defense for...
32 CFR 151.5 - Reports on the exercise of foreign criminal jurisdiction.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 32 National Defense 1 2011-07-01 2011-07-01 false Reports on the exercise of foreign criminal jurisdiction. 151.5 Section 151.5 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE.... The Department of the Army is designated as executive agent within the Department of Defense for...
Mills, Jessica B.; Park, Jae Hong; Peters, Thomas M.
2016-01-01
We evaluated the robust, lightweight DiSCmini (DM) aerosol monitor for its ability to measure the concentration and mean diameter of submicrometer aerosols. Tests were conducted with monodispersed and polydispersed aerosols composed of two particle types (sodium chloride, NaCl, and spark generated metal particles, which simulate particles found in welding fume) at three different steady-state concentration ranges (Low, <103; Medium, 103–104; and High, >104 particles/cm3). Particle number concentration, lung deposited surface area (LDSA) concentration, and mean size measured with the DM were compared to those measured with reference instruments, a scanning mobility particle sizer (SMPS) and a handheld condensation particle counter (CPC). Particle number concentrations measured with the DM were within 21% of those measured by reference instruments for polydisperse aerosols. Poorer agreement was observed for monodispersed aerosols (±35% for most tests and +130% for 300-nm NaCl). LDSA concentrations measured by the DM were 96% to 155% of those estimated with the SMPS. The geometric mean diameters measured with the DM were within 30% of those measured with the SMPS for monodispersed aerosols and within 25% for polydispersed aerosols (except for the case when the aerosol contained a substantial number of particles larger than 300 nm). The accuracy of the DM is reasonable for particles smaller than 300 nm but caution should be exercised when particles larger than 300 nm are present. PMID:23473056
Social cognitive theory: an agentic perspective.
Bandura, A
2001-01-01
The capacity to exercise control over the nature and quality of one's life is the essence of humanness. Human agency is characterized by a number of core features that operate through phenomenal and functional consciousness. These include the temporal extension of agency through intentionality and forethought, self-regulation by self-reactive influence, and self-reflectiveness about one's capabilities, quality of functioning, and the meaning and purpose of one's life pursuits. Personal agency operates within a broad network of sociostructural influences. In these agentic transactions, people are producers as well as products of social systems. Social cognitive theory distinguishes among three modes of agency: direct personal agency, proxy agency that relies on others to act on one's behest to secure desired outcomes, and collective agency exercised through socially coordinative and interdependent effort. Growing transnational embeddedness and interdependence are placing a premium on collective efficacy to exercise control over personal destinies and national life.
Rowsey, Pamela Johnson; Metzger, Bonnie L; Carlson, John; Gordon, Christopher J
2006-02-01
Chronic exercise conditioning has been shown to alter basal thermoregulatory processes as well as the response to inflammatory agents. Two such agents, lipopolysaccharide (LPS) and turpentine (TPT) are inducers of fever in rats. LPS, given intraperitoneally (i.p.), involves a systemic inflammatory response whereas TPT given intramuscularly (i.m.) elicits a localized inflammation. We assessed if chronic exercise training in the rat would alter the thermoregulatory response to LPS and TPT. Core temperature (T (c)) and motor activity were monitored by radiotelemetry. Female Sprague Dawley rats were divided into two groups (trained and sedentary) and housed at an ambient temperature of 22 degrees C. Animals voluntarily trained on running wheels for 8 weeks. In the first study, trained and sedentary female rats were injected i.p. with LPS (50 microg/kg) or an equal volume of 0.9% normal saline. In another study, trained and sedentary female rats were injected i.m. with TPT (10 microl)/rat or an equal volume of 0.9% normal saline. The time course of the LPS fever was very short compared to TPT. TPT injected animals displayed a smaller but more prolonged fever compared to LPS; however, training accentuated the febrile response to LPS (DeltaT (c)=0.6 degrees C in sedentary and 1.2 degrees C in trained). Training had a slight suppression on TPT-induced fever during the daytime but had no effect on motor activity or nighttime T (c). In contrast, exercise training led to a marked increase in the pyrogenic effects of LPS. We conclude that the effect of exercise training and source of infection (i.e., systemic versus localized in muscle) on fever is directly linked to type of pyrogenic agent.
Evaluation of supraspinatus strengthening exercises based on fiber bundle architectural changes.
Sachdeva, R; Farthing, J P; Kim, S Y
2017-07-01
Supraspinatus strengthening is an integral part of rehabilitation programs. However, there is disparity regarding the best exercise. Thus, we investigated the effects of supraspinatus strengthening exercises on muscle fiber bundle architecture using real-time ultrasound. Participants were randomized into full-can (FC; n = 12), empty-can (EC; n = 11,) and prone horizontal abduction (PHA; n = 11) groups and performed three sessions/week for 8 weeks. Each session involved four sets of exercise for weeks 1-4 and six sets for weeks 5-8 with eight repetitions/set. Images of supraspinatus were captured in 0° (relaxed) and 60° (contracted) glenohumeral abduction. Fiber bundle length (FBL), pennation angle, and muscle thickness were measured at beginning, mid, and end of training. Maximum isometric abduction strength was measured in full-can, empty-can, and prone horizontal abduction positions using a hand-held dynamometer. FBL decreased after 4 weeks in FC [relaxed: Δ = -0.54 cm, P = 0.001, d = 0.92; contracted: Δ = -0.27 cm, P = 0.008, d = 0.27] and EC [relaxed: Δ = -0.59 cm, P = 0.008, d = 0.86; contracted: Δ = -0.36 cm, P = 0.013, d = 0.59], but not in PHA [relaxed: Δ = -0.11, P = 0.121, d = 0.31; contracted: Δ = -0.06 cm, P = 0.486, d = 0.13]. Strength increased significantly from week 4-8 only in PHA (Δ = +0.96 kg, P = 0.004, d = 0.47) when tested in prone horizontal abduction position. Maintenance of FBL with increased strength indicates prone horizontal abduction may be a better exercise to strengthen supraspinatus. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Effect of Laser Therapy on Chronic Osteoarthritis of the Knee in Older Subjects
Youssef, Enas Fawzey; Muaidi, Qassim Ibrahim; Shanb, Alsayed Abdelhameed
2016-01-01
Introduction: Osteoarthritis (OA) is a common degenerative joint disease particularly in older subjects. It is usually associated with pain, restricted range of motion, muscle weakness, difficulties in daily living activities and impaired quality of life. To determine the effects of adding two different intensities of low-level laser therapy (LLLT) to exercise training program on pain severity, joint stiffness, physical function, isometric muscle strength, range of motion of the knee, and quality of life in older subjects with knee OA. Methods: Patients were randomly assigned into three groups. They received 16 sessions, 2 sessions/week for 8 weeks. Group-I: 18 patients were treated with a laser dose of 6 J/cm2 with a total dose of 48 J. Group-II: 18 patients were treated with a laser dose of 3 J/cm2 with a total dose of 27 J. Group-III: 15 patients were treated with laser without emission as a placebo. All patients received same exercise training program including stretching and strengthening exercises. Patients were evaluated before and after intervention by visual analogue scale (VAS), the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index for quality of life, handheld dynamometer and universal goniometer. Results: T test revealed that there was a significant reduction in VAS and pain intensity, an increase in isometric muscle strength and range of motion of the knee as well as increase in physical functional ability in three treatment groups. Also analysis of variance (ANOVA) proved significant differences among them and the post hoc tests (LSD) test showed the best improvements for patients of the first group. Conclusion: It can be concluded that addition of LLLT to exercise training program is more effective than exercise training alone in the treatment of older patients with chronic knee OA and the rate of improvement may be dose dependent, as with 6 J/cm2 or 3 J/cm2. PMID:27330707
Handheld computers in critical care.
Lapinsky, S E; Weshler, J; Mehta, S; Varkul, M; Hallett, D; Stewart, T E
2001-08-01
Computing technology has the potential to improve health care management but is often underutilized. Handheld computers are versatile and relatively inexpensive, bringing the benefits of computers to the bedside. We evaluated the role of this technology for managing patient data and accessing medical reference information, in an academic intensive-care unit (ICU). Palm III series handheld devices were given to the ICU team, each installed with medical reference information, schedules, and contact numbers. Users underwent a 1-hour training session introducing the hardware and software. Various patient data management applications were assessed during the study period. Qualitative assessment of the benefits, drawbacks, and suggestions was performed by an independent company, using focus groups. An objective comparison between a paper and electronic handheld textbook was achieved using clinical scenario tests. During the 6-month study period, the 20 physicians and 6 paramedical staff who used the handheld devices found them convenient and functional but suggested more comprehensive training and improved search facilities. Comparison of the handheld computer with the conventional paper text revealed equivalence. Access to computerized patient information improved communication, particularly with regard to long-stay patients, but changes to the software and the process were suggested. The introduction of this technology was well received despite differences in users' familiarity with the devices. Handheld computers have potential in the ICU, but systems need to be developed specifically for the critical-care environment.
Doctors' experience with handheld computers in clinical practice: qualitative study.
McAlearney, Ann Scheck; Schweikhart, Sharon B; Medow, Mitchell A
2004-05-15
To examine doctors' perspectives about their experiences with handheld computers in clinical practice. Qualitative study of eight focus groups consisting of doctors with diverse training and practice patterns. Six practice settings across the United States and two additional focus group sessions held at a national meeting of general internists. 54 doctors who did or did not use handheld computers. Doctors who used handheld computers in clinical practice seemed generally satisfied with them and reported diverse patterns of use. Users perceived that the devices helped them increase productivity and improve patient care. Barriers to use concerned the device itself and personal and perceptual constraints, with perceptual factors such as comfort with technology, preference for paper, and the impression that the devices are not easy to use somewhat difficult to overcome. Participants suggested that organisations can help promote handheld computers by providing advice on purchase, usage, training, and user support. Participants expressed concern about reliability and security of the device but were particularly concerned about dependency on the device and over-reliance as a substitute for clinical thinking. Doctors expect handheld computers to become more useful, and most seem interested in leveraging (getting the most value from) their use. Key opportunities with handheld computers included their use as a stepping stone to build doctors' comfort with other information technology and ehealth initiatives and providing point of care support that helps improve patient care.
Handheld computers in critical care
Lapinsky, Stephen E; Weshler, Jason; Mehta, Sangeeta; Varkul, Mark; Hallett, Dave; Stewart, Thomas E
2001-01-01
Background Computing technology has the potential to improve health care management but is often underutilized. Handheld computers are versatile and relatively inexpensive, bringing the benefits of computers to the bedside. We evaluated the role of this technology for managing patient data and accessing medical reference information, in an academic intensive-care unit (ICU). Methods Palm III series handheld devices were given to the ICU team, each installed with medical reference information, schedules, and contact numbers. Users underwent a 1-hour training session introducing the hardware and software. Various patient data management applications were assessed during the study period. Qualitative assessment of the benefits, drawbacks, and suggestions was performed by an independent company, using focus groups. An objective comparison between a paper and electronic handheld textbook was achieved using clinical scenario tests. Results During the 6-month study period, the 20 physicians and 6 paramedical staff who used the handheld devices found them convenient and functional but suggested more comprehensive training and improved search facilities. Comparison of the handheld computer with the conventional paper text revealed equivalence. Access to computerized patient information improved communication, particularly with regard to long-stay patients, but changes to the software and the process were suggested. Conclusions The introduction of this technology was well received despite differences in users' familiarity with the devices. Handheld computers have potential in the ICU, but systems need to be developed specifically for the critical-care environment. PMID:11511337
Improving car passengers' comfort and experience by supporting the use of handheld devices.
van Veen, S A T; Hiemstra-van Mastrigt, S; Kamp, I; Vink, P
2014-01-01
There is a demand for interiors to support other activities in a car than controlling the vehicle. Currently, this is the case for the car passengers and--in the future--autonomous driving cars will also facilitate drivers to perform other activities. One of these activities is working with handheld devices. Previous research shows that people experience problems when using handheld devices in a moving vehicle and the use of handheld devices generally causes unwanted neck flexion [Young et al. 2012; Sin and Zu 2011; Gold et al.2011]. In this study, armrests are designed to support the arms when using handheld devices in a driving car in order to decrease neck flexion. Neck flexion was measured by attaching markers on the C7 and tragus. Discomfort was indicated on a body map on a scale 1-10. User experience was evaluated in a semi-structured interview. Neck flexion is significantly decreased by the support of the armrests and approaches a neutral position. Furthermore, overall comfort and comfort in the neck region specifically are significantly increased. Subjects appreciate the body posture facilitated by the armrests and 9 out of 10 prefer using handheld devices with the armrests compared to using handheld devices without the armrests. More efforts are needed to develop the mock-up into an established product, but the angles and dimensions presented in this study could serve as guidelines.
Live broadcast of laparoscopic surgery to handheld computers.
Gandsas, A; McIntire, K; Park, A
2004-06-01
Thanks to advances in computer power and miniaturization technology, portable electronic devices are now being used to assist physicians with various applications that extend far beyond Web browsing or sending e-mail. Handheld computers are used for electronic medical records, billing, coding, and to enable convenient access to electronic journals for reference purposes. The results of diagnostic investigations, such as laboratory results, study reports, and still radiographic pictures, can also be downloaded into portable devices for later view. Handheld computer technology, combined with wireless protocols and streaming video technology, has the added potential to become a powerful educational tool for medical students and residents. The purpose of this study was to assess the feasibility of transferring multimedia data in real time to a handheld computer via a wireless network and displaying them on the computer screens of clients at remote locations. A live laparoscopic splenectomy was transmitted live to eight handheld computers simultaneously through our institution's wireless network. All eight viewers were able to view the procedure and to hear the surgeon's comments throughout the entire duration of the operation. Handheld computer technology can play a key role in surgical education by delivering information to surgical residents or students when they are geographically distant from the actual event. Validation of this new technology by conducting clinical research is still needed to determine whether resident physicians or medical students can benefit from the use of handheld computers.
NASA Astrophysics Data System (ADS)
Duma, V.-F.; Demian, D.; Sinescu, C.; Cernat, R.; Dobre, G.; Negrutiu, M. L.; Topala, F. I.; Hutiu, Gh.; Bradu, A.; Podoleanu, A. G.
2016-03-01
We present the handheld scanning probes that we have recently developed in our current project for biomedical imaging in general and for Optical Coherence Tomography (OCT) in particular. OCT is an established, but dynamic imagistic technique based on laser interferometry, which offers micrometer resolutions and millimeters penetration depths. With regard to existing devices, the newly developed handheld probes are simple, light and relatively low cost. Their design is described in detail to allow for the reproduction in any lab, including for educational purposes. Two probes are constructed almost entirely from off-the-shelf components, while a third, final variant is constructed with dedicated components, in an ergonomic design. The handheld probes have uni-dimensional (1D) galvanometer scanners therefore they achieve transversal sections through the biological sample investigated - in contrast to handheld probes equipped with bi-dimensional (2D) scanners that can also achieve volumetric (3D) reconstructions of the samples. These latter handheld probes are therefore also discussed, as well as the possibility to equip them with galvanometer 2D scanners or with Risley prisms. For galvanometer scanners the optimal scanning functions studied in a series of previous works are pointed out; these functions offer a higher temporal efficiency/duty cycle of the scanning process, as well as artifact-free OCT images. The testing of the handheld scanning probes in dental applications is presented, for metal ceramic prosthesis and for teeth.
Choosing a Hand-Held Inventory Device
ERIC Educational Resources Information Center
Green, Lois; Hughes, Janet; Neff, Verne; Notartomas, Trish
2008-01-01
In spring of 2006, a task force was charged to look at the feasibility of acquiring hand-held inventory devices for the Pennsylvania State University Libraries (PSUL). The task force's charge was not to look at the whole concept of doing an inventory, but rather to focus on the feasibility of acquiring hand-held devices to use in an inventory.…
PDAs in Teacher Education: A Case Study Examining Mobile Technology Integration
ERIC Educational Resources Information Center
Franklin, Teresa; Sexton, Colleen; Lu, Young; Ma, Hongyan
2007-01-01
The classroom computer is no longer confined to a box on the desk. Mobile handheld computing devices have evolved into powerful and affordable learning tools. Handheld technologies are changing the way people access and work with information. The use of Personal Digital Assistants (PDAs or handhelds) has been an evolving part of the business world…
Portable control device for networked mobile robots
Feddema, John T.; Byrne, Raymond H.; Bryan, Jon R.; Harrington, John J.; Gladwell, T. Scott
2002-01-01
A handheld control device provides a way for controlling one or multiple mobile robotic vehicles by incorporating a handheld computer with a radio board. The device and software use a personal data organizer as the handheld computer with an additional microprocessor and communication device on a radio board for use in controlling one robot or multiple networked robots.
My-Mini-Pet: A Handheld Pet-Nurturing Game to Engage Students in Arithmetic Practices
ERIC Educational Resources Information Center
Liao, C. C. Y.; Chen, Z-H.; Cheng, H. N. H.; Chen, F-C.; Chan, T-W.
2011-01-01
In the last decade, more and more games have been developed for handheld devices. Furthermore, the popularity of handheld devices and increase of wireless computing can be taken advantage of to provide students with more learning opportunities. Games also could bring promising benefits--specifically, motivating students to learn/play, sustaining…
Caban-Martinez, Alberto J; Clarke, Tainya C; Davila, Evelyn P; Fleming, Lora E; Lee, David J
2011-04-01
Novel low-cost approaches for conducting rapid health assessments and health promotion interventions among underserved worker groups are needed. Recruitment and participation of construction workers is particularly challenging due to their often transient periods of work at any one construction site, and their limited time during work to participate in such studies. In the present methodology report, we discuss the experience, advantages and disadvantages of using touch screen handheld devices for the collection of field data from a largely underserved worker population. In March 2010, a workplace-centered pilot study to examine the feasibility of using a handheld personal device for the rapid health assessment of construction workers in two South Florida Construction sites was undertaken. A 45-item survey instrument, including health-related questions on tobacco exposure, workplace safety practices, musculoskeletal disorders and health symptoms, was programmed onto Apple iPod Touch® devices. Language sensitive (English and Spanish) recruitment scripts, verbal consent forms, and survey questions were all preloaded onto the handheld devices. The experience (time to survey administration and capital cost) of the handheld administration method was recorded and compared to approaches available in the extant literature. Construction workers were very receptive to the recruitment, interview and assessment processes conducted through the handheld devices. Some workers even welcomed the opportunity to complete the questionnaire themselves using the touch screen handheld device. A list of advantages and disadvantages emerged from this experience that may be useful in the rapid health assessment of underserved populations working in a variety of environmental and occupational health settings. Handheld devices, which are relatively inexpensive, minimize survey response error, and allow for easy storage of data. These technological research modalities are useful in the collection and assessment of environmental and occupational research data.
Veterans at Risk: The Health Effects of Mustard Gas and Lewisite
1993-01-01
to Mustard Gas During WWII Testing Programs 370 F. Summary of the Department of the Army Report: Use of Volunteers in Chemical Agent Research 378 Key...concentrations of mustard agents or Lewisite in gas chambers or in field exercises over contaminated ground areas. The human subjects had experienced a...wide range of exposures to mustard agents or Lewisite, from mild (a drop of agent on the arm in "patch" tests) to quite severe (repeated gas chamber
Wiley, Joshua S; Shelley, Jacob T; Cooks, R Graham
2013-07-16
We describe a handheld, wireless low-temperature plasma (LTP) ambient ionization source and its performance on a benchtop and a miniature mass spectrometer. The source, which is inexpensive to build and operate, is battery-powered and utilizes miniature helium cylinders or air as the discharge gas. Comparison of a conventional, large-scale LTP source against the handheld LTP source, which uses less helium and power than the large-scale version, revealed that the handheld source had similar or slightly better analytical performance. Another advantage of the handheld LTP source is the ability to quickly interrogate a gaseous, liquid, or solid sample without requiring any setup time. A small, 7.4-V Li-polymer battery is able to sustain plasma for 2 h continuously, while the miniature helium cylinder supplies gas flow for approximately 8 continuous hours. Long-distance ion transfer was achieved for distances up to 1 m.
Wiktelius, Daniel; Ahlinder, Linnea; Larsson, Andreas; Höjer Holmgren, Karin; Norlin, Rikard; Andersson, Per Ola
2018-08-15
Collecting data under field conditions for forensic investigations of chemical warfare agents calls for the use of portable instruments. In this study, a set of aged, crude preparations of sulfur mustard were characterized spectroscopically without any sample preparation using handheld Raman and portable IR instruments. The spectral data was used to construct Random Forest multivariate models for the attribution of test set samples to the synthetic method used for their production. Colored and fluorescent samples were included in the study, which made Raman spectroscopy challenging although fluorescence was diminished by using an excitation wavelength of 1064 nm. The predictive power of models constructed with IR or Raman data alone, as well as with combined data was investigated. Both techniques gave useful data for attribution. Model performance was enhanced when Raman and IR spectra were combined, allowing correct classification of 19/23 (83%) of test set spectra. The results demonstrate that data obtained with spectroscopy instruments amenable for field deployment can be useful in forensic studies of chemical warfare agents. Copyright © 2018 Elsevier B.V. All rights reserved.
Hagland, Mark
2010-08-01
Not only are hospital, health system, and medical group ClOs and clinical informaticists deploying handheld mobile devices across their enterprises as clinical computing tools; clinicians, especially physicians, are increasingly bringing their own BlackBerrys, iPhones, iPads, Android devices, and other handhelds, into patient care organizations for their personal clinical use. Not surprisingly, the challenges--as well as the opportunities--are multilayered and complex, and include the strategic planning, infrastructure, clinician preference, clinician workflow, and security issues involved in the emerging mobile handheld revolution. The diversity of approaches among ClOs and other healthcare IT leaders on such issues is striking, and underscores the need for flexibility and nimbleness going forward.
The reliability and validity of a three-camera foot image system for obtaining foot anthropometrics.
O'Meara, Damien; Vanwanseele, Benedicte; Hunt, Adrienne; Smith, Richard
2010-08-01
The purpose was to develop a foot image capture and measurement system with web cameras (the 3-FIS) to provide reliable and valid foot anthropometric measures with efficiency comparable to that of the conventional method of using a handheld anthropometer. Eleven foot measures were obtained from 10 subjects using both methods. Reliability of each method was determined over 3 consecutive days using the intraclass correlation coefficient and root mean square error (RMSE). Reliability was excellent for both the 3-FIS and the handheld anthropometer for the same 10 variables, and good for the fifth metatarsophalangeal joint height. The RMSE values over 3 days ranged from 0.9 to 2.2 mm for the handheld anthropometer, and from 0.8 to 3.6 mm for the 3-FIS. The RMSE values between the 3-FIS and the handheld anthropometer were between 2.3 and 7.4 mm. The 3-FIS required less time to collect and obtain the final variables than the handheld anthropometer. The 3-FIS provided accurate and reproducible results for each of the foot variables and in less time than the conventional approach of a handheld anthropometer.
Ultra-compact switchable SLO/OCT handheld probe design
NASA Astrophysics Data System (ADS)
LaRocca, Francesco; Nankivil, Derek; DuBose, Theodore; Farsiu, Sina; Izatt, Joseph A.
2015-03-01
Handheld scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT) systems facilitate imaging of young children and subjects that have difficulty fixating. More compact and lightweight probes allow for better portability and increased comfort for the operator of the handheld probe. We describe a very compact, novel SLO and OCT handheld probe design. A single 2D microelectromechanical systems (MEMS) scanner and a custom optical design using a converging beam prior to the scanner permitted significant reduction in the system size. Our design utilized a combination of commercial and custom optics that were optimized in Zemax to achieve near diffraction-limited resolution of 8 μm over a 7° field of view. The handheld probe has a form factor of 7 x 6 x 2.5 cm and a weight of only 94 g, which is over an order of magnitude lighter than prior SLO-OCT handheld probes. Images were acquired from a normal subject with an incident power on the eye under the ANSI limit. With this device, which is the world's lightest and smallest SLO-OCT system, we were able to visualize parafoveal cone photoreceptors and nerve fiber bundles without the use of adaptive optics.
Importance of exercise immunology in health promotion.
Neto, J C Rosa; Lira, F S; de Mello, M T; Santos, Ronaldo Vagner T
2011-11-01
Chronic physical exercise with adequate intensity and volume associated with sufficient recovery promotes adaptations in several physiological systems. While intense and exhaustive exercise is considered an important immunosuppressor agent and increases the incidence of upper respiratory tract infections (URTI), moderate regular exercise has been associated with significant disease protection and is a complementary treatment of many chronic diseases. The effects of chronic exercise occur because physical training can induce several physiological, biochemical and psychological adaptations. More recently, the effect of acute exercise and training on the immunological system has been discussed, and many studies suggest the importance of the immune system in prevention and partial recovery in pathophysiological situations. Currently, there are two important hypotheses that may explain the effects of exercise and training on the immune system. These hypotheses including (1) the effect of exercise upon hormones and cytokines (2) because exercise can modulate glutamine concentration. In this review, we discuss the hypothesis that exercise may modulate immune functions and the importance of exercise immunology in respect to chronic illnesses, chronic heart failure, malnutrition and inflammation.
Rhinoplasty perioperative database using a personal digital assistant.
Kotler, Howard S
2004-01-01
To construct a reliable, accurate, and easy-to-use handheld computer database that facilitates the point-of-care acquisition of perioperative text and image data specific to rhinoplasty. A user-modified database (Pendragon Forms [v.3.2]; Pendragon Software Corporation, Libertyville, Ill) and graphic image program (Tealpaint [v.4.87]; Tealpaint Software, San Rafael, Calif) were used to capture text and image data, respectively, on a Palm OS (v.4.11) handheld operating with 8 megabytes of memory. The handheld and desktop databases were maintained secure using PDASecure (v.2.0) and GoldSecure (v.3.0) (Trust Digital LLC, Fairfax, Va). The handheld data were then uploaded to a desktop database of either FileMaker Pro 5.0 (v.1) (FileMaker Inc, Santa Clara, Calif) or Microsoft Access 2000 (Microsoft Corp, Redmond, Wash). Patient data were collected from 15 patients undergoing rhinoplasty in a private practice outpatient ambulatory setting. Data integrity was assessed after 6 months' disk and hard drive storage. The handheld database was able to facilitate data collection and accurately record, transfer, and reliably maintain perioperative rhinoplasty data. Query capability allowed rapid search using a multitude of keyword search terms specific to the operative maneuvers performed in rhinoplasty. Handheld computer technology provides a method of reliably recording and storing perioperative rhinoplasty information. The handheld computer facilitates the reliable and accurate storage and query of perioperative data, assisting the retrospective review of one's own results and enhancement of surgical skills.
Rahimy, Ehsan; Reddy, Sahitya; DeCroos, Francis Char; Khan, M Ali; Boyer, David S; Gupta, Omesh P; Regillo, Carl D; Haller, Julia A
2015-08-01
To evaluate the visual acuity agreement between a standard back-illuminated Early Treatment Diabetic Retinopathy Study (ETDRS) chart and a handheld internally illuminated ETDRS chart. Two-center prospective study. Seventy patients (134 eyes) with retinal pathology were enrolled between October 2012 and August 2013. Visual acuity was measured using both the ETDRS chart and the handheld device by masked independent examiners after best protocol refraction. Examination was performed in the same room under identical illumination and testing conditions. The mean number of letters seen was 63.0 (standard deviation: 19.8 letters) and 61.2 letters (standard deviation: 19.1 letters) for the ETDRS chart and handheld device, respectively. Mean difference per eye between the ETDRS and handheld device was 1.8 letters. A correlation coefficient (r) of 0.95 demonstrated a positive linear correlation between ETDRS chart and handheld device measured acuities. Intraclass correlation coefficient was performed to assess the reproducibility of the measurements made by different observers measuring the same quantity and was calculated to be 0.95 (95% confidence interval: 0.93-0.96). Agreement was independent of retinal disease. The strong correlation between measured visual acuity using the ETDRS and handheld equivalent suggests that they may be used interchangeably, with accurate measurements. Potential benefits of this device include convenience and portability, as well as the ability to assess ETDRS visual acuity without a dedicated testing lane.
Doctors' experience with handheld computers in clinical practice: qualitative study
McAlearney, Ann Scheck; Schweikhart, Sharon B; Medow, Mitchell A
2004-01-01
Objective To examine doctors' perspectives about their experiences with handheld computers in clinical practice. Design Qualitative study of eight focus groups consisting of doctors with diverse training and practice patterns. Setting Six practice settings across the United States and two additional focus group sessions held at a national meeting of general internists. Participants 54 doctors who did or did not use handheld computers. Results Doctors who used handheld computers in clinical practice seemed generally satisfied with them and reported diverse patterns of use. Users perceived that the devices helped them increase productivity and improve patient care. Barriers to use concerned the device itself and personal and perceptual constraints, with perceptual factors such as comfort with technology, preference for paper, and the impression that the devices are not easy to use somewhat difficult to overcome. Participants suggested that organisations can help promote handheld computers by providing advice on purchase, usage, training, and user support. Participants expressed concern about reliability and security of the device but were particularly concerned about dependency on the device and over-reliance as a substitute for clinical thinking. Conclusions Doctors expect handheld computers to become more useful, and most seem interested in leveraging (getting the most value from) their use. Key opportunities with handheld computers included their use as a stepping stone to build doctors' comfort with other information technology and ehealth initiatives and providing point of care support that helps improve patient care. PMID:15142920
Look who's talking! A roadside survey of drivers' cell phone use.
Young, Kristie L; Rudin-Brown, Christina M; Lenné, Michael G
2010-12-01
The objective of this study was to quantify Melbourne drivers' rates of handheld and hands-free phone use and the driver, vehicle, site, and time characteristics associated with phone use. Additionally, this study sought to examine any change in the prevalence of handheld cell phone use by Melbourne drivers between 2006 and 2009. Observational survey of vehicle drivers at various times of the day and week at 3 sites across metropolitan Melbourne during May 2009. A total of 195 (3.4%) of the 5813 drivers observed were using handheld phones and 81 (1.4%) were using hands-free phones. This represents a significant increase in handheld phone usage rates compared to those found in an earlier study conducted in Melbourne in 2006. Cell phone use was associated with a range of driver, vehicle, site, and time characteristics. Handheld phone users were predominately young or middle-aged drivers who drove cars or 4-wheel-drive vehicles (4WDs), and this activity was more likely to occur in the late afternoon. Use of hands-free phones did not differ significantly across gender, age group, vehicle type, observation site, or time of day; however, use of hands-free phones was higher on weekdays compared to weekends. Despite legislation being in place, drivers' handheld cell phone use is still a major road safety concern, particularly for young and middle-aged drivers. The effectiveness of other strategies for decreasing handheld usage rates, including increased surveillance and tougher penalties, need to be ascertained.
Mathew, J Itty; Cadnum, Jennifer L; Sankar, Thriveen; Jencson, Annette L; Kundrapu, Sirisha; Donskey, Curtis J
2016-06-01
Mobile handheld devices used in health care settings may become contaminated with health care-associated pathogens. We demonstrated that an enclosed ultraviolet-C radiation device was effective in rapidly reducing methicillin-resistant Staphylococcus aureus, and with longer exposure times, Clostridium difficile spores, on glass slides and reducing contamination on in-use mobile handheld devices. Published by Elsevier Inc.
The sounds of handheld audio players.
Rudy, Susan F
2007-01-01
Hearing experts and public health organizations have longstanding hearing safety concerns about personal handheld audio devices, which are growing in both number and popularity. This paper reviews the maximum sound levels of handheld compact disc players, MP3 players, and an iPod. It further reviews device factors that influence the sound levels produced by these audio devices and ways to reduce the risk to hearing during their use.
Moradi, Saleh; Nima, Ali A; Rapp Ricciardi, Max; Archer, Trevor; Garcia, Danilo
2014-01-01
Performance monitoring might have an adverse influence on call center agents' well-being. We investigate how performance, over a 6-month period, is related to agents' perceptions of their learning climate, character strengths, well-being (subjective and psychological), and physical activity. Agents (N = 135) self-reported perception of the learning climate (Learning Climate Questionnaire), character strengths (Values In Action Inventory Short Version), well-being (Positive Affect, Negative Affect Schedule, Satisfaction With Life Scale, Psychological Well-Being Scales Short Version), and how often/intensively they engaged in physical activity. Performance, "time on the phone," was monitored for 6 consecutive months by the same system handling the calls. Performance was positively related to having opportunities to develop, the character strengths clusters of Wisdom and Knowledge (e.g., curiosity for learning, perspective) and Temperance (e.g., having self-control, being prudent, humble, and modest), and exercise frequency. Performance was negatively related to the sense of autonomy and responsibility, contentedness, the character strengths clusters of Humanity and Love (e.g., helping others, cooperation) and Justice (e.g., affiliation, fairness, leadership), positive affect, life satisfaction and exercise Intensity. Call centers may need to create opportunities to develop to increase agents' performance and focus on individual differences in the recruitment and selection of agents to prevent future shortcomings or worker dissatisfaction. Nevertheless, performance measurement in call centers may need to include other aspects that are more attuned with different character strengths. After all, allowing individuals to put their strengths at work should empower the individual and at the end the organization itself. Finally, physical activity enhancement programs might offer considerable positive work outcomes.
Moradi, Saleh; Nima, Ali A.; Rapp Ricciardi, Max; Archer, Trevor; Garcia, Danilo
2014-01-01
Background: Performance monitoring might have an adverse influence on call center agents' well-being. We investigate how performance, over a 6-month period, is related to agents' perceptions of their learning climate, character strengths, well-being (subjective and psychological), and physical activity. Method: Agents (N = 135) self-reported perception of the learning climate (Learning Climate Questionnaire), character strengths (Values In Action Inventory Short Version), well-being (Positive Affect, Negative Affect Schedule, Satisfaction With Life Scale, Psychological Well-Being Scales Short Version), and how often/intensively they engaged in physical activity. Performance, “time on the phone,” was monitored for 6 consecutive months by the same system handling the calls. Results: Performance was positively related to having opportunities to develop, the character strengths clusters of Wisdom and Knowledge (e.g., curiosity for learning, perspective) and Temperance (e.g., having self-control, being prudent, humble, and modest), and exercise frequency. Performance was negatively related to the sense of autonomy and responsibility, contentedness, the character strengths clusters of Humanity and Love (e.g., helping others, cooperation) and Justice (e.g., affiliation, fairness, leadership), positive affect, life satisfaction and exercise Intensity. Conclusion: Call centers may need to create opportunities to develop to increase agents' performance and focus on individual differences in the recruitment and selection of agents to prevent future shortcomings or worker dissatisfaction. Nevertheless, performance measurement in call centers may need to include other aspects that are more attuned with different character strengths. After all, allowing individuals to put their strengths at work should empower the individual and at the end the organization itself. Finally, physical activity enhancement programs might offer considerable positive work outcomes. PMID:25002853
Bland, Matthew; Sutherland, Alex
2017-01-01
Supplementing local police forces is a burgeoning multibillion-dollar private security industry. Millions of formal surveillance agents in public settings are tasked to act as preventative guardians, as their high visibility presence is hypothesized to create a deterrent threat to potential offenders. Yet, rigorous evidence is lacking. We randomly assigned all train stations in the South West of England that experienced crime into treatment and controls conditions over a six-month period. Treatment consisted of directed patrol by uniformed, unarmed security agents. Hand-held trackers on every agent yielded precise measurements of all patrol time in the stations. Count-based regression models, estimated marginal means and odds-ratios are used to assess the effect of these patrols on crimes reported to the police by victims, as well as new crimes detected by police officers. Outcomes are measured at both specified target locations to which security guards were instructed to attend, as well as at the entire station complexes. Analyses show that 41% more patrol visits and 29% more minutes spent by security agents at treatment compared to control stations led to a significant 16% reduction in victim-generated crimes at the entirety of the stations’ complexes, with a 49% increase in police-generated detections at the target locations. The findings illustrate the efficacy of private policing for crime prevention theory. PMID:29211735
Weight Control: Attitudes of Dieters and Change Agents.
ERIC Educational Resources Information Center
Parham, Ellen S.; And Others
1991-01-01
Survey explores attitudes toward weight loss/weight control among 2 groups of change agents--40 dietitians and 42 fitness instructors--and among 96 people trying to lose weight. Significant differences were found in terms of importance in weight control of diet, drugs, exercise, religion, and will power; in importance of being of normal weight;…
The Functions of Mass Media in the Political Socialization of Adolescents.
ERIC Educational Resources Information Center
Adoni, Hanna
1979-01-01
Suggests that the mass media serve as socializing agents by providing direct linkage to media and contents which are essential for the development of political values, and by contributing to the structuring of social contexts in which adolescents may exercise such value orientations and reinforce ties with primary socializing agents. (JMF)
2014-10-01
maneuver • Traditional “ Brick and Mortar ” training models – Difficult to train regularly due to logistics/budget restrictions – Doesn’t scale...complexity, scenario, location , and resources available • Scalable 4-cell planning construct – Exercise Control (White Cell) – Threat Emulation (Red...business impact) • Collaborative effort Trusted Agents ( SMEs ) – Threats – Cyber defense capabilities – Policies and procedures – Project and/or
2010-10-01
An Empirical Study on Operator Interface Design for Handheld Devices to Control Micro Aerial Vehicles Ming Hou...Report DRDC Toronto TR 2010-075 October 2010 An Empirical Study on Operator Interface Design for Handheld Devices to...drives the need for a small and light controller which will not hinder a soldier carrying it. This requirement brings an issue of designing an
Development of a persistent chemical agent simulation system
NASA Technical Reports Server (NTRS)
1983-01-01
A Persistent Chemical Agent Simulation System was developed (PCASS) to simulate, for force-on-force training exercises, the field environment produced by the presence of persistent chemical agents. Such a simulant system must satisfy several requirements to be of value as a training aid. Specifically, it must provide for realistic training which will generate competency in at least the following areas: (1) detection of the persistent agent presence; (2) proper use of protective equipment and procedures; (3) determination of the extent of contamination; and (4) decontamination of equipment and personnel.
Ray, Midge N; Houston, Thomas K; Yu, Feliciano B; Menachemi, Nir; Maisiak, Richard S; Allison, Jeroan J; Berner, Eta S
2006-01-01
The authors developed and evaluated a rating scale, the Attitudes toward Handheld Decision Support Software Scale (H-DSS), to assess physician attitudes about handheld decision support systems. The authors conducted a prospective assessment of psychometric characteristics of the H-DSS including reliability, validity, and responsiveness. Participants were 82 Internal Medicine residents. A higher score on each of the 14 five-point Likert scale items reflected a more positive attitude about handheld DSS. The H-DSS score is the mean across the fourteen items. Attitudes toward the use of the handheld DSS were assessed prior to and six months after receiving the handheld device. Cronbach's Alpha was used to assess internal consistency reliability. Pearson correlations were used to estimate and detect significant associations between scale scores and other measures (validity). Paired sample t-tests were used to test for changes in the mean attitude scale score (responsiveness) and for differences between groups. Internal consistency reliability for the scale was alpha = 0.73. In testing validity, moderate correlations were noted between the attitude scale scores and self-reported Personal Digital Assistant (PDA) usage in the hospital (correlation coefficient = 0.55) and clinic (0.48), p < 0.05 for both. The scale was responsive, in that it detected the expected increase in scores between the two administrations (3.99 (s.d. = 0.35) vs. 4.08, (s.d. = 0.34), p < 0.005). The authors' evaluation showed that the H-DSS scale was reliable, valid, and responsive. The scale can be used to guide future handheld DSS development and implementation.
Lab-on-a-bubble: direct and indirect assays with portable Raman instrumentation
NASA Astrophysics Data System (ADS)
Carron, Keith; Schmit, Virginia; Scott, Brandon; Martoglio, Richard
2012-10-01
Lab-on-a-Bubble (LoB) is a new method for SERS (Surface Enhanced Raman Scattering) assays that combines separationand concentration of the assay results. A direct LoB assay is comprised of gold nanoparticles coupled directly to the ~30 μm diameter buoyant silica bubble. The direct LoB method was evaluated with cyanide and 5,5'-dithiobis(2-nitrobenzoic acid) (DTNB). An indirect assay uses the same ~ 30 μm diameter buoyant silica bubble and a silica coated SERS reporter. Both the bubble and SERS reporter are coated with a coupling agent for the analyte. The assay measures the amount of SERS reporter coupled to the bubble through a sandwich created by the analyte. The couling agent could consist of an immunological coupling agent (antibody) or a nucleic acid coupling agent (single strand DNA). The indirect LoB method was examined with Cholera toxin (CT) and antibodies against the β subunit. An LOD of ~ 170 pptrillion was measured for cyanide and a limit of detection of 1100 ng was found for CT. Instrumentation for the assay and a novel technique of dynamic SERS (DSERS) will also be discussed. The instrument is a small hand-held Raman device called the CBEx (Chemical Biological Explosive) with a novel raster system to detect heterogeneous or light sensitive materials. DSERS is a mathematical algorithm which eliminates background interference in SERS measurements with colloidal nanoparticles.
Long-term effects of handheld cell phone laws on driver handheld cell phone use.
McCartt, Anne T; Hellinga, Laurie A; Strouse, Laura M; Farmer, Charles M
2010-04-01
As of October 2009, seven U.S. states and the District of Columbia (D.C.) ban driving while talking on a handheld cell phone. Long-term effects on driver handheld phone use in D.C., New York State, and Connecticut were examined. The percentage of drivers talking on handheld cell phones was measured over time with daytime observation surveys in the jurisdictions with bans and comparison jurisdictions without bans. Trends were modeled using Poisson regression to estimate differences between actual rates and rates that would have been expected without a ban. The D.C. ban immediately lowered the percentage of drivers talking on handheld cell phones by 41 percent. Nearly 5 years later, the rate was 43 percent lower than would have been expected without the ban. Use in Connecticut declined 76 percent immediately after the ban; 3.5 years later, use was 65 percent lower than would have been expected without the ban. In New York, use declined 47 percent immediately after the ban; 7 years later, use was 24 percent lower than expected without the ban. Fifteen months after the laws took effect, compliance in New York was lower than in D.C., and the difference appeared due to more intensive enforcement in D.C. However, this linkage is no longer clear because enforcement in New York picked up such that 2008 levels of enforcement appeared comparable in D.C. and New York, whereas enforcement in Connecticut lagged behind. In all three jurisdictions, the chance that a violator would receive a citation was low, and there were no publicized targeted enforcement campaigns. Jurisdictional bans have reduced handheld phone use and appear capable of maintaining reductions for the long term. However, it is unknown whether overall phone use is lower because many drivers may have switched to hands-free devices. Further research is needed to determine whether reduced handheld cell phone use has reduced crashes.
Nassar, Cíntia Cristina Souza; Bondan, Eduardo Fernandes; Alouche, Sandra Regina
2009-09-01
Multiple sclerosis is a demyelinating disease of the central nervous system associated with varied levels of disability. The impact of early physiotherapeutic interventions in the disease progression is unknown. We used an experimental model of demyelination with the gliotoxic agent ethidium bromide and early aquatic exercises to evaluate the motor performance of the animals. We quantified the number of footsteps and errors during the beam walking test. The demyelinated animals walked fewer steps with a greater number of errors than the control group. The demyelinated animals that performed aquatic exercises presented a better motor performance than those that did not exercise. Therefore aquatic exercising was beneficial to the motor performance of rats in this experimental model of demyelination.
Cardiorespiratory fitness and muscle strength in pancreatic cancer patients.
Clauss, Dorothea; Tjaden, Christine; Hackert, Thilo; Schneider, Lutz; Ulrich, Cornelia M; Wiskemann, Joachim; Steindorf, Karen
2017-09-01
Cancer patients frequently experience reduced physical fitness due to the disease itself as well as treatment-related side effects. However, studies on physical fitness in pancreatic cancer patients are missing. Therefore, we assessed cardiorespiratory fitness and muscle strength of pancreatic cancer patients. We included 65 pancreatic cancer patients, mostly after surgical resection. Cardiorespiratory fitness was assessed using cardiopulmonary exercise testing (CPET) and 6-min walk test (6MWT). Hand-held dynamometry was used to evaluate isometric muscle strength. Physical fitness values were compared to reference values of a healthy population. Associations between sociodemographic and clinical variables with patients' physical fitness were analyzed using multiple regression models. Cardiorespiratory fitness (VO 2 peak, 20.5 ± 6.9 ml/min/kg) was significantly lower (-24%) compared to healthy reference values. In the 6MWT pancreatic cancer patients nearly reached predicted values (555 vs. 562 m). Maximal voluntary isometric contraction (MVIC) of the upper (-4.3%) and lower extremities (-13.8%) were significantly lower compared to reference values. Overall differences were larger in men than those in women. Participating in regular exercise in the year before diagnosis was associated with greater VO 2 peak (p < .05) and MVIC of the knee extensors (p < .05). Pancreatic cancer patients had significantly impaired physical fitness with regard to both cardiorespiratory function and isometric muscle strength, already in the early treatment phase (median 95 days after surgical resection). Our findings underline the need to investigate exercise training in pancreatic cancer patients to counteract the loss of physical fitness.
NASA Astrophysics Data System (ADS)
Blain, Matthew G.; Riter, Leah S.; Cruz, Dolores; Austin, Daniel E.; Wu, Guangxiang; Plass, Wolfgang R.; Cooks, R. Graham
2004-08-01
Breakthrough improvements in simplicity and reductions in the size of mass spectrometers are needed for high-consequence fieldable applications, including error-free detection of chemical/biological warfare agents, medical diagnoses, and explosives and contraband discovery. These improvements are most likely to be realized with the reconceptualization of the mass spectrometer, rather than by incremental steps towards miniaturization. Microfabricated arrays of mass analyzers represent such a conceptual advance. A massively parallel array of micrometer-scaled mass analyzers on a chip has the potential to set the performance standard for hand-held sensors due to the inherit selectivity, sensitivity, and universal applicability of mass spectrometry as an analytical method. While the effort to develop a complete micro-MS system must include innovations in ultra-small-scale sample introduction, ion sources, mass analyzers, detectors, and vacuum and power subsystems, the first step towards radical miniaturization lies in the design, fabrication, and characterization of the mass analyzer itself. In this paper we discuss design considerations and results from simulations of ion trapping behavior for a micrometer scale cylindrical ion trap (CIT) mass analyzer (internal radius r0 = 1 [mu]m). We also present a description of the design and microfabrication of a 0.25 cm2 array of 106 one-micrometer CITs, including integrated ion detectors, constructed in tungsten on a silicon substrate.
NASA Technical Reports Server (NTRS)
Aase, J. K.; Siddoway, F. H.; Millard, J. P.
1984-01-01
An attempt has been made to relate hand-held radiometer measurements, and airborne multispectral scanner readings, with both different wheat stand densities and grain yield. Aircraft overflights were conducted during the tillering, stem extension and heading period stages of growth, while hand-held radiometer readings were taken throughout the growing season. The near-IR/red ratio was used in the analysis, which indicated that both the aircraft and the ground measurements made possible a differentiation and evaluation of wheat stand densities at an early enough growth stage to serve as the basis of management decisions. The aircraft data also corroborated the hand-held radiometer measurements with respect to yield prediction. Winterkill was readily evaluated.
Insulin Management Strategies for Exercise in Diabetes.
Zaharieva, Dessi P; Riddell, Michael C
2017-10-01
There is no question that regular exercise can be beneficial and lead to improvements in overall cardiovascular health. However, for patients with diabetes, exercise can also lead to challenges in maintaining blood glucose balance, particularly if patients are prescribed insulin or certain oral hypoglycemic agents. Hypoglycemia is the most common adverse event associated with exercise and insulin therapy, and the fear of hypoglycemia is also the greatest barrier to exercise for many patients. With the appropriate insulin dose adjustments and, in some cases, carbohydrate supplementation, blood glucose levels can be better managed during exercise and in recovery. In general, insulin strategies that help facilitate weight loss with regular exercise and recommendations around exercise adjustments to prevent hypoglycemia and hyperglycemia are often not discussed with patients because the recommendations can be complex and may differ from one individual to the next. This is a review of the current published literature on insulin dose adjustments and starting-point strategies for patients with diabetes in preparation for safe exercise. Copyright © 2017 Diabetes Canada. Published by Elsevier Inc. All rights reserved.
AMPK and PPARδ agonists are exercise mimetics
Narkar, Vihang A.; Downes, Michael; Yu, Ruth T.; Embler, Emi; Wang, Yong-Xu; Banayo, Ester; Mihaylova, Maria M.; Nelson, Michael C.; Zou, Yuhua; Juguilon, Henry; Kang, Heonjoong; Shaw, Reuben; Evans, Ronald M.
2008-01-01
SUMMARY The benefits of endurance exercise on general health make it desirable to identify orally active agents that would mimic or potentiate the effects of exercise to treat metabolic diseases. Although certain natural compounds, such as reseveratrol, have endurance-enhancing activities, their exact metabolic targets remain elusive. We therefore tested the effect of pathway-specific drugs on endurance capacities of mice in a treadmill running test. We found that PPARβ/δ agonist and exercise training synergistically increase oxidative myofibers and running endurance in adult mice. Because training activates AMPK and PGC1α, we then tested whether the orally active AMPK agonist AICAR might be sufficient to overcome the exercise requirement. Unexpectedly, even in sedentary mice, 4 weeks of AICAR treatment alone induced metabolic genes and enhanced running endurance by 44%. These results demonstrate that AMPK-PPARδ pathway can be targeted by orally active drugs to enhance training adaptation or even to increase endurance without exercise. PMID:18674809
Beavers as Agents of Biogeomorphic Change: A Review and Suggestions for Teaching Exercises.
ERIC Educational Resources Information Center
Butler, David R.
1991-01-01
Discusses beavers and their geomorphic impacts on their environment. Considers dam building, bank burrowing, and canal building. Suggests using the beaver as a classroom and field trip example to illustrate animals' effects on the physical landscape. Provides a review of published works on beavers in their roles as geomorphic agents. (DK)
Development of Medical Technology for Contingency Response to Marrow Toxic Agents
2014-07-11
the transplant community about the critical importance of establishing a nationwide contingency response plan. 2. Rapid Identification of Matched...to rapidly identify the best available donor or cord blood unit for each patient utilizing its state-of-the-art communication infrastructure, sample...York City (NYC)-NY State Radiological Disaster - tabletop exercise 2. Minneapolis-full scale exercise 3. Dana Farber Cancer Institute – full
Chen, Zhidan; Yan, Yanqin
2017-09-01
Bacopa monnieri has effect on the nervous system, digestive system and blood circulation systems. In this paper, the authors conducted pharmacological analysis on Bacopa monniera and its innovative pharmaceutical preparation of promote motor function. The extract of the drug has some effect on relieving the fatigue and providing the movement function. By analyzing the composition and efficacy of Chinese herbal extracts, it can be seen that these drugs have obvious effect on improving immunity. Experimental results show that the agent can increase the liver glycogen energy reserves, reduce Bla and BUN levels, balance and energy metabolism of muscle cells in the environment, it plays a positive role to improve the exercise capacity and exercise fatigue.
McNally, George; Frey, Rosemary; Crossan, Michael
2017-03-01
Personally owned handheld referencing technology such as smartphones or tablets, and the adjunct applications (apps) that can be used on them, are becoming a part of everyday life for the New Zealand population. In common with the population at large, student nurses have embraced this technology since the advent of the Apple iPhone in 2010. Little is known internationally or in New Zealand about the way student nurses may apply personally owned handheld referencing technology to their education process. The perceptions of New Zealand nurse managers, toward personally owned handheld referencing technology, could not be located. Using a qualitative descriptive methodology, semi structured interviews were conducted with New Zealand student nurses (n = 13), and nurse managers (n = 5) about their perceptions of use of personally owned handheld referencing technology as an educational tool in clinical settings. A thematic analysis was conducted on the resulting text. Student nurses said they wanted to use their own handheld referencing technology to support clinical decisions. Nurse managers perceived the use of personally owned handheld referencing technology as unprofessional, and do not trust younger cohorts of student nurses to act ethically when using this technology. This research supports historical research findings from the student perspective about the usefulness of older hand held referencing devices to augment clinical decisions. However, due to perceptions held by nurse mangers regarding professional behaviour, safety and the perceived institutional costs of managing personally owned handheld referencing technology, the practice may remain problematic in the studied setting. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cheng, Guang-Shing; Campbell, Angela P.; Xie, Hu; Stednick, Zach; Callais, Cheryl; Leisenring, Wendy M.; Englund, Janet A.; Chien, Jason W.; Boeckh, Michael
2016-01-01
BACKGROUND Early detection of subclinical lung function decline may help identify allogeneic hematopoietic cell transplantation (HCT) recipients who are at increased risk for late non-infectious pulmonary complications including bronchiolitis obliterans syndrome (BOS). We evaluated the use of handheld spirometry in this population. METHODS Allogeneic HCT recipients enrolled in a single center observational trial performed weekly spirometry with a handheld spirometer for one year after transplantation. Participants performed pulmonary function tests in an outpatient laboratory setting at 3 time points: pre-transplant, day 80 and 1 year post-transplant. Correlation between the two methods was assessed by Pearson and Spearman correlations; agreement was assessed using Bland-Altman plots. RESULTS A total of 437 subjects had evaluable pulmonary function tests. Correlation for FEV1 was r=0.954 (p<.0001) at day 80 and r=0.931 (p<.0001) at 1 year when the handheld and laboratory tests were performed within one day of each other. Correlation for handheld FEV6 with laboratory FVC was r=0.914 (p<.0001) at day 80 and r=0.826 (p<.0001) at 1 year. The bias, or the mean difference (handheld minus laboratory) for FEV1 at day 80 and 1 year was −0.13L (−0.63, 0.37) and −0.10L (−0.77, 0.56), respectively. FEV6 showed greater bias at day 80 [−0.51L (−1.44, 0.42)] and 1 year [−0.40L (−1.81, 1.01)]. CONCLUSIONS Handheld spirometry correlated well with laboratory spirometry after allogeneic HCT and may be useful for self-monitoring of patients for early identification of airflow obstruction. PMID:26748162
Driver hand-held cellular phone use: a four-year analysis.
Eby, David W; Vivoda, Jonathon M; St Louis, Renée M
2006-01-01
The use of hand-held cellular (mobile) phones while driving has stirred more debate, passion, and research than perhaps any other traffic safety issue in the past several years. There is ample research showing that the use of either hand-held or hands-free cellular phones can lead to unsafe driving patterns. Whether or not these performance deficits increase the risk of crash is difficult to establish, but recent studies are beginning to suggest that cellular phone use elevates crash risk. The purpose of this study was to assess changes in the rate of hand-held cellular phone use by motor-vehicle drivers on a statewide level in Michigan. This study presents the results of 13 statewide surveys of cellular phone use over a 4-year period. Hand-held cellular phone use data were collected through direct observation while vehicles were stopped at intersections and freeway exit ramps. Data were weighted to be representative of all drivers traveling during daylight hours in Michigan. The study found that driver hand-held cellular phone use has more than doubled between 2001 and 2005, from 2.7% to 5.8%. This change represents an average increase of 0.78 percentage points per year. The 5.8% use rate observed in 2005 means that at any given daylight hour, around 36,550 drivers were conversing on cellular phones while driving on Michigan roadways. The trend line fitted to these data predicts that by the year 2010, driver hand-held cellular phone use will be around 8.6%, or 55,000 drivers at any given daylight hour. These results make it clear that cellular phone use while driving will continue to be an important traffic safety issue, and highlight the importance of continued attempts to generate new ways of alleviating this potential hazard.
Handheld Metal Detector for Metallic Foreign Body Ingestion in Pediatric Emergency.
Hamzah, Hazwani Binte; James, Vigil; Manickam, Suraj; Ganapathy, Sashikumar
2018-01-04
Foreign body ingestion is a common problem for which children present to the emergency department. The most common ingested foreign bodies among children are coins. Metal detector is an equipment, which measures a change in inductance of a coil when an electroconductive material is placed near it and produces an audio-visual signal. The present study was conducted to determine the effectiveness and feasibility of HMD in the local Pediatric population. This was a prospective study conducted in the pediatric emergency department among children presenting with history of foreign body ingestion. The outcome measured was presence or absence of metallic foreign body detected on handheld metal detector examination. During the study period, 36 patients with history of foreign body ingestion presented to the emergency department. Among these, 28 were metallic foreign body ingestions. Coins were the most common type of foreign body ingested. Among the metallic foreign bodies ingested, all the coins were accurately identified by the handheld metal detector. Non-coin metallic foreign bodies like metallic screw, needle and stapler pin were not identified by the handheld metal detector. The study demonstrates that handheld metal detector can be safely and reliably used as a screening tool in the process of detecting ingested coins. The plain radiograph still appears to be superior as it accurately localizes sharp metallic objects as well as cell batteries (button batteries) which need to be detected early and removed in order to prevent complications. Handheld metal detector is an effective tool that can be used in the follow up of patients to confirm whether the coin like metallic foreign body has been expelled. Handheld metal detector examination is more sensitive than traditional X-ray examination to detect radiolucent metallic foreign bodies like aluminium.
2009-06-01
Blackberry handheld) device. After each voice command activation, the medic provided voice comments to be recorded in Observer Notepad over Voice...vial (up-right corner of picture) upon voice activation from the medic’s Blackberry handheld. The NPS UAS which was controlled by voice commands...Voice Portal using a standard Blackberry handheld with a head set. The results demonstrated sufficient accuracy for controlling the tactical sensor
Surgical guidance system using hand-held probe with accompanying positron coincidence detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Majewski, Stanislaw; Weisenberger, Andrew G.
A surgical guidance system offering different levels of imaging capability while maintaining the same hand-held convenient small size of light-weight intra-operative probes. The surgical guidance system includes a second detector, typically an imager, located behind the area of surgical interest to form a coincidence guidance system with the hand-held probe. This approach is focused on the detection of positron emitting biomarkers with gamma rays accompanying positron emissions from the radiolabeled nuclei.
Automated Hand-Held UXO Detection, Classification & Discrimination Sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bell, Thomas H.
2000-06-12
The research focused on procedures for target discrimination and classification using hand-held EMI sensors. The idea is to have a small, portable sensor that can be operated in a sweep or similar pattern in front of the operator, and that is capable of distinguishing between buried UXO and clutter on the spot. Curing Phase 1, we developed the processing techniques for distinguishing between buried UXO and clutter using the EM61-HH hand-held metal detector.
Validation of a portable nitric oxide analyzer for screening in primary ciliary dyskinesias.
Harris, Amanda; Bhullar, Esther; Gove, Kerry; Joslin, Rhiannon; Pelling, Jennifer; Evans, Hazel J; Walker, Woolf T; Lucas, Jane S
2014-02-10
Nasal nitric oxide (nNO) levels are very low in primary ciliary dyskinesia (PCD) and it is used as a screening test. We assessed the reliability and usability of a hand-held analyser in comparison to a stationary nitric oxide (NO) analyser in 50 participants (15 healthy, 13 PCD, 22 other respiratory diseases; age 6-79 years). Nasal NO was measured using a stationary NO analyser during a breath-holding maneuver, and using a hand-held analyser during tidal breathing, sampling at 2 ml/sec or 5 ml/sec. The three methods were compared for their specificity and sensitivity as a screen for PCD, their success rate in different age groups, within subject repeatability and acceptability. Correlation between methods was assessed. Valid nNO measurements were obtained in 94% of participants using the stationary analyser, 96% using the hand-held analyser at 5 ml/sec and 76% at 2 ml/sec. The hand-held device at 5 ml/sec had excellent sensitivity and specificity as a screening test for PCD during tidal breathing (cut-off of 30 nL/min,100% sensitivity, >95% specificity). The cut-off using the stationary analyser during breath-hold was 38 nL/min (100% sensitivity, 95% specificity). The stationary and hand-held analyser (5 ml/sec) showed reasonable within-subject repeatability(% coefficient of variation = 15). The hand-held NO analyser provides a promising screening tool for PCD.
Ground-based thermal imaging of stream surface temperatures: Technique and evaluation
Bonar, Scott A.; Petre, Sally J.
2015-01-01
We evaluated a ground-based handheld thermal imaging system for measuring water temperatures using data from eight southwestern USA streams and rivers. We found handheld thermal imagers could provide considerably more spatial information on water temperature (for our unit one image = 19,600 individual temperature measurements) than traditional methods could supply without a prohibitive amount of effort. Furthermore, they could provide measurements of stream surface temperature almost instantaneously compared with most traditional handheld thermometers (e.g., >20 s/reading). Spatial temperature analysis is important for measurement of subtle temperature differences across waterways, and identification of warm and cold groundwater inputs. Handheld thermal imaging is less expensive and equipment intensive than airborne thermal imaging methods and is useful under riparian canopies. Disadvantages of handheld thermal imagers include their current higher expense than thermometers, their susceptibility to interference when used incorrectly, and their slightly lower accuracy than traditional temperature measurement methods. Thermal imagers can only measure surface temperature, but this usually corresponds to subsurface temperatures in well-mixed streams and rivers. Using thermal imaging in select applications, such as where spatial investigations of water temperature are needed, or in conjunction with stationary temperature data loggers or handheld electronic or liquid-in-glass thermometers to characterize stream temperatures by both time and space, could provide valuable information on stream temperature dynamics. These tools will become increasingly important to fisheries biologists as costs continue to decline.
NASA Astrophysics Data System (ADS)
Chen, Jianbo; Guo, Baolin; Yan, Rui; Sun, Suqin; Zhou, Qun
2017-07-01
With the utilization of the hand-held equipment, Fourier transform infrared (FT-IR) spectroscopy is a promising analytical technique to minimize the time cost for the chemical identification of herbal materials. This research examines the feasibility of the hand-held FT-IR spectrometer for the on-site testing of herbal materials, using Lonicerae Japonicae Flos (LJF) and Lonicerae Flos (LF) as examples. Correlation-based linear discriminant models for LJF and LF are established based on the benchtop and hand-held FT-IR instruments. The benchtop FT-IR models can exactly recognize all articles of LJF and LF. Although a few LF articles are misjudged at the sub-class level, the hand-held FT-IR models are able to exactly discriminate LJF and LF. As a direct and label-free analytical technique, FT-IR spectroscopy has great potential in the rapid and automatic chemical identification of herbal materials either in laboratories or in fields. This is helpful to prevent the spread and use of adulterated herbal materials in time.
Toohill, Jocelyn; Soong, Barbara; Meldrum, Melissa
2006-12-01
Risk management is integral to the provision of contemporary health care. As maternity practices change and with a commitment on women being at the centre of care, one strategy has been for women to retain their records during the antenatal period. This paper explores the return rate of the pregnancy handheld record in a major tertiary facility and discusses the risk management implications when the record is not available upon presentation to the treating practitioner. Four audits were conducted over a 2 year period to determine the return rate of the pregnancy handheld record at time of admission for labour and birth. A total of 1096 records were returned out of a possible 1256 during the study. A 6.6% increase in the return rate was achieved over the 4 audit periods (82-88.5%) with an overall return rate of 85%. Our audit highlights the need for consumers, clinicians and heath care facilities to consider the advantages and disadvantages of the pregnancy handheld record, as well as the medico-legal responsibilities that ultimately fall back on the health facility.
Translating exercise biology into the Venezuelan medical education and health care system.
Del Corral, Pedro
2007-09-01
In the absence of pharmacological agents, physical exercise was widely used by physicians in the late 19th century to treat a number of maladies. In the 1950's, epidemiological evidence suggested an association between physical activity and health, and increased interest in clinical exercise biology. By the 1990's, sufficient research data was accumulated on the benefits of exercise, such that North American medical associations, government agencies, and the World Health Organization have published guidelines on exercise for public and clinical populations. Despite this, leaders in medical education have remained reluctant to incorporate exercise biology into the core medical curriculum, or to systematically implement it in graduate medical education. This work reviews Venezuelan exercise biology literature, and its medical applications. Venezuelan scientists and clinicians have invested efforts in cardiopulmonary exercise testing, skeletal muscle adaptations to training and exercise cardiovascular pharmacology in patients, sedentary subjects and athletes. It is suggested here, that there is a need to develop education and research programs in basic and clinical exercise biology in the formal training of medical students, physicians in residency programs, and allied health care professionals. Tentative steps to initiate this process are proposed.
NASA Astrophysics Data System (ADS)
Diem, J.; Elliott, W.; Criswell, B.; Morrow, C. A.
2012-12-01
A suite of NASA-sponsored, Web-based exercises are in development for an introductory weather and climate course at Georgia State University (GSU) to improve climate literacy among undergraduate students. An extremely small percentage of the students are STEM majors. The exercises make extensive use of NASA resources and are guided in part by the concepts in Climate Literacy: The Essential Principles of Climate Science. At least two thousand undergraduate students have completed a majority of the exercises over the past two years. Nine of the twelve exercises in the course are connected strongly to climate literacy. The topics of those nine exercises are as follows: (1) Solar Irradiance, (2) Stratospheric Ozone, (3) Tropospheric Air, (4) The Carbon Cycle, (5) Global Surface Temperature, (6) Glacial-Interglacial Cycles, (7) Temperature Changes during the Past Millennium, (8) Climate & Ecosystems, and (9) Current & Future Climate Change. Two of the exercises (Tropospheric Air and The Carbon Cycle) make use of carbon dioxide (CO2) measurements made by students themselves and by a stationary CO2 monitor at GSU. The three remaining exercises, The Hadley Cell, Atlanta Weather, and Air Pollution, are less connected to multiple climate-literacy concepts; nonetheless, they provide a more complete experience for the students in the understanding of climate processes, differences between weather and climate, and human impacts on the atmosphere. All exercises are based on an inquiry-based learning cycle (i.e. 7 Es) and require substantial amounts of engagement, applied thinking, and critical thinking by the students. Not only do students become knowledgeable about the essential principles of climate change, especially global warming, but extensive use of geographical-information software and hand-held measurement devices has provided students with training in geography and technology. Student attitudes towards the labs were gathered via an on-line, anonymous survey from hundreds of students in Geography 1112 during the Fall semester of 2010. Students liked the use of high-quality imagery and animations, using Google™ earth, using Microsoft® Excel for calculations and chart production, going outside to collect data, and working in groups. Students did not like the large number of questions in some of the labs, not receiving a "lecture" in the beginning lab exercise, and improperly working Web links. Students suggested having a small lecture at the beginning in addition to having the topics be presented in the lecture sessions before doing the lab exercises as way to improve the labs. Therefore, students desired a more traditional approach to instruction. Seven lab instructors, all of whom were graduate students in the Department of Geosciences, were interviewed by the project evaluator in April of 2011. The main findings were as follows: the instructors viewed themselves as facilitators of the student-centered exercises; the students are uncomfortable with an inquiry-based approach; and there is disconnection between the lecture and lab portions of the course. Future work involves major pedagogical renovations to the exercises, training the lab instructors in the leading of inquiry-based exercises, and assessing student learning of climate-change concepts using pre- and post-tests.
1987-12-01
acting as an agent of the owner, and the owner contracts directly with several prime or trade contractors. There are four different agreements associated...safety precautions and programs in connection with the project or for the construction manager’s obligations as the agent of the owner. AIA A201/CM...require the general contractor to exercise reasonable care for safety of the subcontractor’s employees. Owners and their agents must be careful that
NASA Astrophysics Data System (ADS)
Frye-Mason, Greg; Leuschen, Martin; Wald, Lara; Paul, Kateri; Hancock, Lawrence F.
2005-05-01
A reactive chromophore developed at MIT exhibits sensitive and selective detection of surrogates for G-class nerve agents. This reporter acts by reacting with the agent to form an intermediate that goes through an internal cyclization reaction. The reaction locks the molecule into a form that provides a strong fluorescent signal. Using a fluorescent sensor platform, Nomadics has demonstrated rapid and sensitive detection of reactive simulants such as diethyl chloro-phosphate (simulant for sarin, soman, and related agents) and diethyl cyanophosphate (simulant for tabun). Since the unreacted chromophore does not fluoresce at the excitation wavelength used for the cyclized reporter, the onset of fluo-rescence can be easily detected. This fluorescence-based detection method provides very high sensitivity and could enable rapid detection at permissible exposure levels. Tests with potential interferents show that the reporter is very selective, with responses from only a few highly toxic, electrophilic chemicals such as phosgene, thionyl chloride, and strong acids such as HF, HCl, and nitric acid. Dimethyl methyl phosphonate (DMMP), a common and inactive simu-lant for other CW detectors, is not reactive enough to generate a signal. The unique selectivity to chemical reactivity means that a highly toxic and hazardous chemical is present when the reporter responds and illustrates that this sensor can provide very low false alarm rates. Current efforts focus on demonstrating the sensitivity and range of agents and toxic industrial chemicals detected with this reporter as well as developing additional fluorescent reporters for a range of chemical reactivity classes. The goal is to produce a hand-held sensor that can sensitively detect a broad range of chemical warfare agent and toxic industrial chemical threats.
The General Adaptation Syndrome: Potential misapplications to resistance exercise.
Buckner, Samuel L; Mouser, J Grant; Dankel, Scott J; Jessee, Matthew B; Mattocks, Kevin T; Loenneke, Jeremy P
2017-11-01
Within the resistance training literature, one of the most commonly cited tenets with respect to exercise programming is the "General Adaptation Syndrome" (GAS). The GAS is cited as a central theory behind the periodization of resistance exercise. However, after examining the original stress research by Hans Selye, the applications of GAS to resistance exercise may not be appropriate. To examine the original work of Hans Selye, as well as the original papers through which the GAS was established as a central theory for periodized resistance exercise. We conducted a review of Selye's work on the GAS, as well as the foundational papers through which this concept was applied to resistance exercise. The work of Hans Selye focused on the universal physiological stress responses noted upon exposure to toxic levels of a variety of pharmacological agents and stimuli. The extrapolations that have been made to resistance exercise appear loosely based on this concept and may not be an appropriate basis for application of the GAS to resistance exercise. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Mobile computing acceptance grows as applications evolve.
Porn, Louis M; Patrick, Kelly
2002-01-01
Handheld devices are becoming more cost-effective to own, and their use in healthcare environments is increasing. Handheld devices currently are being used for e-prescribing, charge capture, and accessing daily schedules and reference tools. Future applications may include education on medications, dictation, order entry, and test-results reporting. Selecting the right handheld device requires careful analysis of current and future applications, as well as vendor expertise. It is important to recognize the technology will continue to evolve over the next three years.
Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children.
Alving, K; Janson, C; Nordvall, L
2006-04-20
Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). A total of 71 subjects (6-60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). Success rate was high (> or = 84%) in both devices for both adults and children. The subjects represented a FENO range of 8-147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children. The new hand-held device will enable the introduction of exhaled NO measurements into the primary health care.
Melloy, Patricia G
2015-01-01
A two-part laboratory exercise was developed to enhance classroom instruction on the significance of p53 mutations in cancer development. Students were asked to mine key information from an international database of p53 genetic changes related to cancer, the IARC TP53 database. Using this database, students designed several data mining activities to look at the changes in the p53 gene from a number of perspectives, including potential cancer-causing agents leading to particular changes and the prevalence of certain p53 variations in certain cancers. In addition, students gained a global perspective on cancer prevalence in different parts of the world. Students learned how to use the database in the first part of the exercise, and then used that knowledge to search particular cancers and cancer-causing agents of their choosing in the second part of the exercise. Students also connected the information gathered from the p53 exercise to a previous laboratory exercise looking at risk factors for cancer development. The goal of the experience was to increase student knowledge of the link between p53 genetic variation and cancer. Students also were able to walk a similar path through the website as a cancer researcher using the database to enhance bench work-based experiments with complementary large-scale database p53 variation information. © 2014 The International Union of Biochemistry and Molecular Biology.
Goldstein, Lizabeth A; Connolly Gibbons, Mary Beth; Thompson, Sarah M; Scott, Kelli; Heintz, Laura; Green, Patricia; Thompson, Donald; Crits-Christoph, Paul
2011-07-01
Computerized administration of mental health-related questionnaires has become relatively common, but little research has explored this mode of assessment in "real-world" settings. In the current study, 200 consumers at a community mental health center completed the BASIS-24 via handheld computer as well as paper and pen. Scores on the computerized BASIS-24 were compared with scores on the paper BASIS-24. Consumers also completed a questionnaire which assessed their level of satisfaction with the computerized BASIS-24. Results indicated that the BASIS-24 administered via handheld computer was highly correlated with pen and paper administration of the measure and was generally acceptable to consumers. Administration of the BASIS-24 via handheld computer may allow for efficient and sustainable outcomes assessment, adaptable research infrastructure, and maximization of clinical impact in community mental health agencies.
Kakio, Tomoko; Yoshida, Naoko; Macha, Susan; Moriguchi, Kazunobu; Hiroshima, Takashi; Ikeda, Yukihiro; Tsuboi, Hirohito; Kimura, Kazuko
2017-09-01
Analytical methods for the detection of substandard and falsified medical products (SFs) are important for public health and patient safety. Research to understand how the physical and chemical properties of SFs can be most effectively applied to distinguish the SFs from authentic products has not yet been investigated enough. Here, we investigated the usefulness of two analytical methods, handheld Raman spectroscopy (handheld Raman) and X-ray computed tomography (X-ray CT), for detecting SFs among oral solid antihypertensive pharmaceutical products containing candesartan cilexetil as an active pharmaceutical ingredient (API). X-ray CT visualized at least two different types of falsified tablets, one containing many cracks and voids and the other containing aggregates with high electron density, such as from the presence of the heavy elements. Generic products that purported to contain equivalent amounts of API to the authentic products were discriminated from the authentic products by the handheld Raman and the different physical structure on X-ray CT. Approach to investigate both the chemical and physical properties with handheld Raman and X-ray CT, respectively, promise the accurate discrimination of the SFs, even if their visual appearance is similar with authentic products. We present a decision tree for investigating the authenticity of samples purporting to be authentic commercial tablets. Our results indicate that the combination approach of visual observation, handheld Raman and X-ray CT is a powerful strategy for nondestructive discrimination of suspect samples.
Neuroradiology Using Secure Mobile Device Review.
Randhawa, Privia A; Morrish, William; Lysack, John T; Hu, William; Goyal, Mayank; Hill, Michael D
2016-04-05
Image review on computer-based workstations has made film-based review outdated. Despite advances in technology, the lack of portability of digital workstations creates an inherent disadvantage. As such, we sought to determine if the quality of image review on a handheld device is adequate for routine clinical use. Six CT/CTA cases and six MR/MRA cases were independently reviewed by three neuroradiologists in varying environments: high and low ambient light using a handheld device and on a traditional imaging workstation in ideal conditions. On first review (using a handheld device in high ambient light), a preliminary diagnosis for each case was made. Upon changes in review conditions, neuroradiologists were asked if any additional features were seen that changed their initial diagnoses. Reviewers were also asked to comment on overall clinical quality and if the handheld display was of acceptable quality for image review. After the initial CT review in high ambient light, additional findings were reported in 2 of 18 instances on subsequent reviews. Similarly, additional findings were identified in 4 of 18 instances after the initial MR review in high ambient lighting. Only one of these six additional findings contributed to the diagnosis made on the initial preliminary review. Use of a handheld device for image review is of adequate diagnostic quality based on image contrast, sharpness of structures, visible artefacts and overall display quality. Although reviewers were comfortable with using this technology, a handheld device with a larger screen may be diagnostically superior.
Dollarhide, Adrian W; Rutledge, Thomas; Weinger, Matthew B; Dresselhaus, Timothy R
2008-04-01
To determine the feasibility of capturing self-reported medication events using a handheld computer-based Medication Event Reporting Tool (MERT). Handheld computers operating the MERT software application were deployed among volunteer physician (n = 185) and nurse (n = 119) participants on the medical wards of four university-affiliated teaching hospitals. Participants were encouraged to complete confidential reports on the handheld computers for medication events observed during the study period. Demographic variables including age, gender, education level, and clinical experience were recorded for all participants. Each MERT report included details on the provider, location, timing and type of medication event recorded. Over the course of 2,311 days of clinician participation, 76 events were reported; the median time for report completion was 231 seconds. The average event reporting rate for all participants was 0.033 reports per clinician shift. Nurses had a significantly higher reporting rate compared to physicians (0.045 vs 0.026 reports/shift, p = .02). Subgroup analysis revealed that attending physicians reported events more frequently than resident physicians (0.042 vs 0.021 reports/shift, p = .03), and at a rate similar to that of nurses (p = .80). Only 5% of MERT medication events were reported to require increased monitoring or treatment. A handheld-based event reporting tool is a feasible method to record medication events in inpatient hospital care units. Handheld reporting tools may hold promise to augment existing hospital reporting systems.
Emergency medicine clerkship encounter and procedure logging using handheld computers.
Penciner, Rick; Siddiqui, Sanam; Lee, Shirley
2007-08-01
Tracking medical student clinical encounters is now an accreditation requirement of medical schools. The use of handheld computers for electronic logging is emerging as a strategy to achieve this. To evaluate the technical feasibility and student satisfaction of a novel electronic logging and feedback program using handheld computers in the emergency department. This was a survey study of fourth-year medical student satisfaction with the use of their handheld computers for electronic logging of patient encounters and procedures. The authors also included an analysis of this technology. Forty-six students participated in this pilot project, logging a total of 2,930 encounters. Students used the logs an average of 7.6 shifts per rotation, logging an average of 8.3 patients per shift. Twenty-nine students (63%) responded to the survey. Students generally found it easy to complete each encounter (69%) and easy to synchronize their handheld computer with the central server (83%). However, half the students (49%) never viewed the feedback Web site and most (79%) never reviewed their logs with their preceptors. Overall, only 17% found the logging program beneficial as a learning tool. Electronic logging by medical students during their emergency medicine clerkship has many potential benefits as a method to document clinical encounters and procedures performed. However, this study demonstrated poor compliance and dissatisfaction with the process. In order for electronic logging using handheld computers to be a beneficial educational tool for both learners and educators, obstacles to effective implementation need to be addressed.
Body weight gain induced by a newer antipsychotic agent reversed as negative symptoms improved.
Koga, M; Nakayama, K
2005-07-01
We describe a patient in whom improvement in negative symptoms contributed to early weight loss and subsequent long-term improvement in weight management. Case report. A 26-year-old woman with schizophrenia gained 7 kg over the course of 1 year after starting treatment with olanzapine. However, as negative symptoms gradually improved with treatment, she became motivated to diet and exercise regularly. She quickly lost 9 kg and subsequently maintained optimal weight (55 kg; body mass index, 24.1 kg/m(2) ). Important strategies for minimizing weight gain in patients taking antipsychotic agents include improving negative symptoms of avolition and apathy, regular monitoring of body weight and potential medical consequences of overweight and obesity, and educating the patient about the importance of diet and regular exercise.
Nascimento, L S; Santos, A C; Lucena, Jms; Silva, Lgo; Almeida, Aem; Brasileiro-Santos, M S
2017-06-02
Resistant hypertension is a specific condition that affects approximately 10% of subjects with hypertension, and is characterized by persistently high blood pressure levels even using therapy of three or more antihypertensive agents or with blood pressure control using therapy with four or more antihypertensive agents. Changes in lifestyle, such as physical exercise, are indicated for controlling blood pressure. However, investigating studies about this therapy in individuals with resistant hypertension are few. This is a randomized controlled clinical trial. Forty-eight patients with resistant hypertension will be submitted to perform four short-term interventions: aerobic exercise sessions (mild-, moderate- and high-intensity) and control session, in random order and on separate days. After the short-term sessions, the patients will be randomly allocated into four groups for 8 weeks of follow-up: mild-, moderate- and high-intensity aerobic exercise, and a control group. The primary outcome is the occurrence of blood pressure reduction (office and ambulatory analysis, and acute and chronic effects). Secondary outcomes are autonomic and hemodynamic mechanisms: cardiac and vasomotor autonomic modulation, spontaneous baroreflex sensitivity, forearm blood flow and vascular resistance. The importance of exercise for hypertension has been known for decades, but little is known about the effects on patients with resistant hypertension. This study will help to understand whether different aerobic exercise intensities can induce different responses, as well as by what mechanisms adjustments in blood pressure levels may occur. ClinicalTrials.gov, ID: NCT02670681 . Registered on 28 January 2016 (first version); Brazilian Registry Platform Clinical Trials: protocol RBR-5q24zh . Registered on 24 June 2015.
Motaghinejad, Majid; Fatima, Sulail; Karimian, Morteza; Ganji, Saeid
2016-01-01
Nicotine is one of the psychostimulant agents displaying parasympathomimetic activity; the chronic neurochemical and behavioral effects of nicotine remain unclear. Exercise lowers stress and anxiety and can act as a non-pharmacologic neuroprotective agent. In this study, the protective effects of exercise in nicotine withdrawal syndrome-induced anxiety, depression, and cognition impairment were investigated. Seventy adult male rats were divided randomly into five groups. Group 1 served as negative control and received normal saline (0.2 mL/rat, i.p.) for 30 days, whereas group 2 (as positive control) received nicotine (6 mg/kg/day, s.c.) for the first 15 days. Groups 4, 5, and 6 were treated with nicotine (6 mg/kg/day, s.c.) for the first 15 days and then were treated with forced exercise, bupropion (20 mg/kg/day, i.p.), or a combination of the two for the following 15 days. Between day 25 and day 30, Morris water maze was used to evaluate spatial learning and memory. From days 31 to 35, the elevated plus maze (EPM), open field test (OFT), forced swim test (FST), and tail suspension test (TST) were used to investigate the level of anxiety and depression in the subjects. Nicotine-dependent animals indicated a reflective depression and anxiety in a dose-dependent manner in FST, EPM, and TST, which were significantly different from the control group and also can significantly attenuate the motor activity and anxiety in OFT. Forced exercise, bupropion, or their combination can attenuate nicotine cessation-induced anxiety, depression, and motor activity in the mentioned behavioral assay. We conclude that forced exercise can protect the brain against nicotine withdrawal-induced anxiety, depression, and cognitive alteration.
Goldblum, O M
2001-02-01
The objectives of this study were: 1) to establish criteria for evaluating handheld computerized prescribing systems; and 2) to evaluate out-of-box performance and features of a new, Palm Operating System (OS)-based, handheld, wireless wide area network (WWAN) prescribing system. The system consisted of a Palm Vx handheld organizer, a Novatel Minstrel V wireless modem, OmniSky wireless internet access and ePhysician ePad 1.1, the Palm OS electronic prescribing software program. A dermatologist familiar with healthcare information technology conducted an evaluation of the performance and features of a new, handheld, WWAN electronic prescribing system in an office practice during a three-month period in 2000. System performance, defined as transmission success rate, was determined from data collected during the three-month trial. Evaluation criteria consisted of an analysis of features found in electronic prescribing systems. All prescriptions written for all patients seen during a three-month period (August - November, 2000) were eligible for inclusion. Prescriptions written for patients who intended to fill them at pharmacies without known facsimile receiving capabilities were excluded from the study. The performance of the system was evaluated using data collected during the study. Criteria for evaluating features of electronic prescribing systems were developed and used to analyze the system employed in this study. During this three-month trial, 200 electronic prescriptions were generated for 132 patients included in the study. Of these prescriptions, 92.5 percent were successfully transmitted to pharmacies. Transmission failures resulted from incorrect facsimile numbers and non-functioning facsimile machines. Criteria established for evaluation of electronic prescribing systems included System (Hardware & Software), Costs, System Features, Printing & Transmission, Formulary & Insurance, Customization, Drug Safety and Security. This study is the first effort to establish comprehensive criteria for evaluating handheld prescribing systems and to evaluate the performance and features of a handheld, electronic prescribing system. The results demonstrated that the evaluated system: 1) was simple to install; 2) successfully interfaced with a commonly used practice management system; 3) was user-friendly and easy to operate; 4) offered a robust variety of standard features; and, 5) resulted in a high rate of success for transmitting electronic prescriptions. The criteria established for the evaluation of features of an electronic prescribing system can be used to critically evaluate the performance and features of other handheld and personal computer-based electronic prescribing systems.
A learning-based agent for home neurorehabilitation.
Lydakis, Andreas; Meng, Yuanliang; Munroe, Christopher; Wu, Yi-Ning; Begum, Momotaz
2017-07-01
This paper presents the iterative development of an artificially intelligent system to promote home-based neurorehabilitation. Although proper, structured practice of rehabilitation exercises at home is the key to successful recovery of motor functions, there is no home-program out there which can monitor a patient's exercise-related activities and provide corrective feedback in real time. To this end, we designed a Learning from Demonstration (LfD) based home-rehabilitation framework that combines advanced robot learning algorithms with commercially available wearable technologies. The proposed system uses exercise-related motion information and electromyography signals (EMG) of a patient to train a Markov Decision Process (MDP). The trained MDP model can enable an agent to serve as a coach for a patient. On a system level, this is the first initiative, to the best of our knowledge, to employ LfD in an health-care application to enable lay users to program an intelligent system. From a rehabilitation research perspective, this is a completely novel initiative to employ machine learning to provide interactive corrective feedback to a patient in home settings.
Sancho, Aintzane; Carrera, Sergio; Arietaleanizbeascoa, Marisol; Arce, Veronica; Gallastegui, Nere Mendizabal; Giné March, Anna; Sanz-Guinea, Aitor; Eskisabel, Araceli; Rodriguez, Ana Lopez; Martín, Rosa A; Lopez-Vivanco, Guillermo; Grandes, Gonzalo
2015-02-06
The optimal form of exercise for individuals with cancer has yet to be identified, but there is evidence that exercise improves their quality of life. The aim of this study is to assess the efficacy and efficiency of an innovative physical exercise programme, for individuals undergoing chemotherapy for breast, gastrointestinal or non-small cell lung tumours, for improving quality of life, reducing level of fatigue, and enhancing functional capacity over time. We will conduct a clinical trial in 66 patients with stage IV breast, gastrointestinal or non-small cell lung cancer, recruited by the Department of Oncology of the referral hospital from 4 primary care health centres of the Basque Health Service (Osakidetza). These patients will be randomised to one of two groups. The treatment common to both groups will be the usual care for cancer: optimized usual drug therapies and strengthening of self-care; in addition, patients in the intervention group will participate in a 2-month exercise programme, including both aerobic and strength exercises, supervised by nurses in their health centre. The principal outcome variable is health-related quality of life, measured blindly with the 30-item European Organization for the Research and Treatment of Cancer Core Quality of Life Questionnaire and Short Form-36 four times: at baseline, and 2, 6 and 12 months later. The secondary outcome variables are fatigue (Functional Assessment of Chronic Illness Therapy-Fatigue questionnaire), functional capacity (6-Minute Walk Test and cardiorespiratory test), muscle strength (hand-held dynamometry and sit-to-stand test), radiological response to treatment (Response Evaluation Criteria In Solid Tumors) and progression-free and overall survival. Age, sex, diagnosis, chemotherapy regimen, Eastern Cooperative Oncology Group performance status and smoking status will be considered as predictive variables. Data will be analysed on an intention-to-treat basis, comparing changes at each time point between groups, adjusting for baseline values by analysis of covariance. As well as achieving the objectives set, this study will provide us with information on patient perception of the care received and an opportunity to develop a project based on collaborative action between the primary care and oncology professionals. ClinicalTrials.gov Identifier: NCT01786122 Registration date: 02/05/2013.
A handheld computer as part of a portable in vivo knee joint load monitoring system
Szivek, JA; Nandakumar, VS; Geffre, CP; Townsend, CP
2009-01-01
In vivo measurement of loads and pressures acting on articular cartilage in the knee joint during various activities and rehabilitative therapies following focal defect repair will provide a means of designing activities that encourage faster and more complete healing of focal defects. It was the goal of this study to develop a totally portable monitoring system that could be used during various activities and allow continuous monitoring of forces acting on the knee. In order to make the monitoring system portable, a handheld computer with custom software, a USB powered miniature wireless receiver and a battery-powered coil were developed to replace a currently used computer, AC powered bench top receiver and power supply. A Dell handheld running Windows Mobile operating system(OS) programmed using Labview was used to collect strain measurements. Measurements collected by the handheld based system connected to the miniature wireless receiver were compared with the measurements collected by a hardwired system and a computer based system during bench top testing and in vivo testing. The newly developed handheld based system had a maximum accuracy of 99% when compared to the computer based system. PMID:19789715
Hand-held computer operating system program for collection of resident experience data.
Malan, T K; Haffner, W H; Armstrong, A Y; Satin, A J
2000-11-01
To describe a system for recording resident experience involving hand-held computers with the Palm Operating System (3 Com, Inc., Santa Clara, CA). Hand-held personal computers (PCs) are popular, easy to use, inexpensive, portable, and can share data among other operating systems. Residents in our program carry individual hand-held database computers to record Residency Review Committee (RRC) reportable patient encounters. Each resident's data is transferred to a single central relational database compatible with Microsoft Access (Microsoft Corporation, Redmond, WA). Patient data entry and subsequent transfer to a central database is accomplished with commercially available software that requires minimal computer expertise to implement and maintain. The central database can then be used for statistical analysis or to create required RRC resident experience reports. As a result, the data collection and transfer process takes less time for residents and program director alike, than paper-based or central computer-based systems. The system of collecting resident encounter data using hand-held computers with the Palm Operating System is easy to use, relatively inexpensive, accurate, and secure. The user-friendly system provides prompt, complete, and accurate data, enhancing the education of residents while facilitating the job of the program director.
Payne, Christopher J; Yang, Guang-Zhong
2014-08-01
Medical robots have evolved from autonomous systems to tele-operated platforms and mechanically-grounded, cooperatively-controlled robots. Whilst these approaches have seen both commercial and clinical success, uptake of these robots remains moderate because of their high cost, large physical footprint and long setup times. More recently, researchers have moved toward developing hand-held robots that are completely ungrounded and manipulated by surgeons in free space, in a similar manner to how conventional instruments are handled. These devices provide specific functions that assist the surgeon in accomplishing tasks that are otherwise challenging with manual manipulation. Hand-held robots have the advantages of being compact and easily integrated into the normal surgical workflow since there is typically little or no setup time. Hand-held devices can also have a significantly reduced cost to healthcare providers as they do not necessitate the complex, multi degree-of-freedom linkages that grounded robots require. However, the development of such devices is faced with many technical challenges, including miniaturization, cost and sterility, control stability, inertial and gravity compensation and robust instrument tracking. This review presents the emerging technical trends in hand-held medical robots and future development opportunities for promoting their wider clinical uptake.
Monitoring of WEEE plastics in regards to brominated flame retardants using handheld XRF.
Aldrian, Alexia; Ledersteger, Alfred; Pomberger, Roland
2015-02-01
This contribution is focused on the on-site determination of the bromine content in waste electrical and electronic equipment (WEEE), in particular waste plastics from television sets (TV) and personal computer monitors (PC) using a handheld X-ray fluorescence (XRF) device. The described approach allows the examination of samples in regards to the compliance with legal specifications for polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) directly after disassembling and facilitates the sorting out of plastics with high contents of brominated flame retardants (BFRs). In all, over 3000 pieces of black (TV) and 1600 pieces of grey (PC) plastic waste were analysed with handheld XRF technique for this study. Especially noticeable was the high percentage of pieces with a bromine content of over 50,000ppm for TV (7%) and PC (39%) waste plastics. The applied method was validated by comparing the data of handheld XRF with results obtained by GC-MS. The results showed the expected and sufficiently accurate correlation between these two methods. It is shown that handheld XRF technique is an effective tool for fast monitoring of large volumes of WEEE plastics in regards to BFRs for on-site measurements. Copyright © 2014 Elsevier Ltd. All rights reserved.
49 CFR 109.11 - Assistance of properly qualified personnel.
Code of Federal Regulations, 2013 CFR
2013-10-01
... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS AND OIL TRANSPORTATION... properly qualified to perform a function that is essential to the agent's exercise of authority under this...
Pharmacological targeting of exercise adaptations in skeletal muscle: Benefits and pitfalls.
Weihrauch, Martin; Handschin, Christoph
2018-01-01
Exercise exerts significant effects on the prevention and treatment of many diseases. However, even though some of the key regulators of training adaptation in skeletal muscle have been identified, this biological program is still poorly understood. Accordingly, exercise-based pharmacological interventions for many muscle wasting diseases and also for pathologies that are triggered by a sedentary lifestyle remain scarce. The most efficacious compounds that induce muscle hypertrophy or endurance are hampered by severe side effects and are classified as doping. In contrast, dietary supplements with a higher safety margin exert milder outcomes. In recent years, the design of pharmacological agents that activate the training program, so-called "exercise mimetics", has been proposed, although the feasibility of such an approach is highly debated. In this review, the most recent insights into key regulatory factors and therapeutic approaches aimed at leveraging exercise adaptations are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.
Matar, Ralph; Renapurkar, Rahul; Obuchowski, Nancy; Menon, Venu; Piraino, David; Schoenhagen, Paul
2015-01-01
Prompt diagnosis and early referral to specialized centers is critical for patients presenting with cardiovascular emergencies, including acute aortic syndromes (AAS). Prior data has suggested that mobile access to imaging studies with hand-held devices can accelerate diagnosis and management. We conducted a study to determine the diagnostic accuracy of a hand-held device compared to conventional dedicated work-stations for diagnosing a spectrum of cardiovascular emergencies, predominantly acute aortic pathology. This study included 104 cases who underwent computed tomography (CT)-scan during "on-call'' hours between January, 2013 and August, 2014 for suspected AAS. Assessment was performed on a hand-held device independently by two readers using an iPhone5 connected via secure connection to web-based PACS servers. The subsequent interpretation from a dedicated workstation coupled with the diagnosis at the time of discharge was used as the reference standard for determining the presence or absence of an acute abnormality. Sensitivity and Specificity were calculated on a per patient basis. Readers' sensitivity and specificity using the hand-held device to diagnose acute chest pathology were calculated. Hand-held device evaluation was determined to have a sensitivity of 85.2% and a specificity of 98.6% by reader A and a sensitivity of 96.3% and specificity of 100% by reader B. Of 103 cases interpreted by both readers, the readers agreed about the diagnosis in 98 cases (95.1%). This study demonstrates that hand-held devices can be a potential useful tool to assist in diagnosis and triage of patients presenting with cardiovascular emergencies. Further studies are needed to assess the impact of screen size and resolution. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
40 CFR 1054.110 - What evaporative emission standards must my handheld equipment meet?
Code of Federal Regulations, 2010 CFR
2010-07-01
... apply starting in the 2013 model year for emission families involving small-volume emission families... the 2012 model year for handheld equipment using nonhandheld engines, and in the 2013 model year for...
Augmented Reality Simulations on Handheld Computers
ERIC Educational Resources Information Center
Squire, Kurt; Klopfer, Eric
2007-01-01
Advancements in handheld computing, particularly its portability, social interactivity, context sensitivity, connectivity, and individuality, open new opportunities for immersive learning environments. This article articulates the pedagogical potential of augmented reality simulations in environmental engineering education by immersing students in…
Development of Hand-Held Thermographic Inspection Technologies
DOT National Transportation Integrated Search
2009-09-01
This study explored the application of hand-held thermographic cameras for the detection of subsurface delaminations in concrete bridges. The goal of the research was to provide maintenance and inspection personnel with an effective tool for detectin...
Development of hand-held thermographic inspection technologies.
DOT National Transportation Integrated Search
2009-09-01
This study explored the application of hand-held thermographic cameras for the detection of subsurface delaminations in concrete : bridges. The goal of the research was to provide maintenance and inspection personnel with an effective tool for detect...
Heavy-metal contamination on training ranges at the Grafenwoehr Training Area, Germany
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zellmer, S.D.; Schneider, J.F.
1993-05-01
Large quantities of lead and other heavy metals are deposited in the environment of weapons ranges during training exercises. This study was conducted to determine the type, degree, and extent of heavy-metal contamination on selected handgun, rifle, and hand-grenade ranges at Grafenwoehr Training Area, Germany. Soil, vegetation, and surface-water samples were collected and analyzed using the inductively-coupled plasma atomic-emission spectroscopy (ICP-AES) method and the toxic characterization leaching procedure (TCLP). The ICP-AES results show that above-normal levels of lead and copper are in the surface soil at the handgun range, high concentrations of lead and copper are in the berm andmore » soil surface at the rifle range, and elevated levels of cadmium and above-normal concentrations of arsenic, copper, and zinc are present in the surface soil at the hand-grenade range. The TCLP results show that surface soils can be considered hazardous waste because of lead content at the rifle range and because of cadmium concentration at the hand-grenade range. Vegetation at the handgun and rifle ranges has above-normal concentrations of lead. At the hand-grenade range, both vegetation and surface water have high levels of cadmium. A hand-held X-ray fluorescence (XRF) spectrum analyzer was used to measure lead concentrations in soils in a field test of the method. Comparison of XRF readings with ICP-AES results for lead indicate that the accuracy and precision of the hand-held XRF unit must improve before the unit can be used as more than a screening tool. Results of this study show that heavy-metal contamination at all three ranges is limited to the surface soil; heavy metals are not being leached into the soil profile or transported into adjacent areas.« less
Baert, Isabel A C; Lluch, Enrique; Struyf, Thomas; Peeters, Greta; Van Oosterwijck, Sophie; Tuynman, Joanna; Rufai, Salim; Struyf, Filip
2018-06-01
The therapeutic value of proprioceptive-based exercises in knee osteoarthritis (KOA) management warrants investigation of proprioceptive testing methods easily accessible in clinical practice. To estimate inter- and intrarater reliability of the knee joint position sense (KJPS) test and knee force sense (KFS) test in subjects with and without KOA. Cross-sectional test-retest design. Two blinded raters performed independently repeated measures of the KJPS and KFS test, using an analogue inclinometer and handheld dynamometer, respectively, in eight KOA patients (12 symptomatic knees) and 26 healthy controls (52 asymptomatic knees). Intraclass correlation coefficients (ICCs; model 2,1), standard error of measurement (SEM) and minimal detectable change with 95% confidence bounds (MDC 95 ) were calculated. For KJPS, results showed good to excellent test-retest agreement (ICCs 0.70-0.95 in KOA patients; ICCs 0.65-0.85 in healthy controls). A 2° measurement error (SEM 1°) was reported when measuring KJPS in multiple test positions and calculating mean repositioning error. Testing KOA patients pre and post therapy a repositioning error larger than 4° (MDC 95 ) is needed to consider true change. Measuring KFS using handheld dynamometry showed poor to fair interrater and poor to excellent intrarater reliability in subjects with and without KOA. Measuring KJPS in multiple test positions using an analogue inclinometer and calculating mean repositioning error is reliable and can be used in clinical practice. We do not recommend the use of the KFS test to clinicians. Further research is required to establish diagnostic accuracy and validity of our KJPS test in larger knee pain populations. Copyright © 2017 Elsevier Ltd. All rights reserved.
Body Segment Kinematics and Energy Expenditure in Active Videogames.
Böhm, Birgit; Hartmann, Michael; Böhm, Harald
2016-06-01
Energy expenditure (EE) in active videogames (AVGs) is a component for assessing its benefit for cardiovascular health. Existing evidence suggests that AVGs are able to increase EE above rest and when compared with playing passive videogames. However, the association between body movement and EE remains unclear. Furthermore, for goal-directed game design, it is important to know the contribution of body segments to EE. This knowledge will help to acquire a certain level of exercise intensity during active gaming. Therefore, the purpose of this study was to determine the best predictors of EE from body segment energies, acceleration, and heart rate during different game situations. EE and body segment movement of 17 subjects, aged 22.1 ± 2.5 years, were measured in two different AVGs. In randomized order, the subjects played a handheld-controlled Nintendo(®) Wii™ tennis (NWT) game and a whole body-controlled Sony EyeToy(®) waterfall (ETW) game. Body segment movement was analyzed using a three-dimensional motion capture system. From the video data, mean values of mechanical energy change and acceleration of 10 body segments were analyzed. Measured EE was significantly higher in ETW (7.8 ± 1.4 metabolic equivalents [METs]) than in NWT (3.4 ± 1.0 METs). The best prediction parameter for the more intense ETW game was the energy change of the right thigh and for the less intense hand-controlled NWT game was the energy change of the upper torso. Segment acceleration was less accurate in predicting EE. The best predictors of metabolic EE were the thighs and the upper torso in whole body and handheld-controlled games, respectively. Increasing movement of these body segments would lead to higher physical activity intensity during gaming, reducing sedentary behavior.
Mashhadi, Nafiseh Shokri; Ghiasvand, Reza; Hariri, Mitra; Askari, Gholamreza; Feizi, Awat; Darvishi, Leila; Hajishafiee, Maryam; Barani, Azam
2013-01-01
Background: Ginger (rich in gingerols and shogaols) rhizomes have been widely used as dietary spices and to treat different diseases in Asia. Cinnamon (containing cinnamic aldehyde and cinnamyl aldehyde) is used as spices and as a pharmacological agent in ancient medicine. Intense exercise can result in oxidative damage to cellular compounds and also muscle soreness. Efficacy of dietary ginger and cinnamon as antioxidant agents and their effectiveness in exercise performance and reducing muscle soreness have been investigated in limited studies on humans. So we studied the effects of dietary ginger and cinnamon on oxidative stress and exercise performance and body composition in Iranian female taekwondo players. Methods: Sixty healthy trained women, aged 13-25 years, were enrolled in the 6 week investigation and randomly categorized in three groups (cinnamon, ginger, or placebo) and received three grams of ginger, cinnamon, or placebo powder each day depending on the group they belonged. Human malondialdehyde (MDA) level, exercise performance, and body composition were evaluated in the beginning and at the end of the study and compared among the groups. Results: Forty-nine of the participants completed the 6 weeks intervention. There was minor decrease in MDA in cinnamon and ginger group compared with the placebo group and significant increase in exercise performance in ginger group (P < 0.01), and considerable increase in skin fold in cinnamon groups (P < 0.01), whereas there were significant accretion in BMI for ginger group (P < 0.1) and cinnamon group (P < 0.05). No significant changes in MDA, EP, and BMI were observed between groups over time. But there were specific changes in skin fold between cinnamon and placebo group (P < 0.05) and cinnamon and ginger groups (P < 0.05). Conclusions: Six weeks administration of ginger and cinnamon in athlete women did not show any significant change in MDA level, body composition, and exercise performance as compared with the placebo group. PMID:23717766
Carpenter, Christopher S; Nguyen, Hai V
2015-11-01
We provide new evidence on the effects of increasingly common driver cellphone bans on self-reported overall, handheld, and hands-free cellphone use while driving by studying Ontario, Canada, which instituted a 3-month education campaign in November 2009 followed by a binding driver cellphone ban in February 2010. Using residents of Alberta as a control group in a difference-in-differences framework, we find visual and regression-based evidence that Ontario's cellphone ban significantly reduced overall and handheld cellphone use. We also find that the policies significantly increased hands-free cellphone use. The reductions in overall and handheld use are driven exclusively by women, whereas the increases in hands-free use are much larger for men. Our results provide the first direct evidence that cellphone bans have the unintended effect of inducing substitution to hands-free devices. Copyright © 2014 John Wiley & Sons, Ltd.
Is a hands-free phone safer than a handheld phone?
Ishigami, Yoko; Klein, Raymond M
2009-01-01
Although it is becoming more and more accepted that driving while talking on a cell phone can be hazardous, most jurisdictions are making handheld phone use illegal while allowing hands-free phone use. The scientific literature exploring the effects of these two types of cell phone use on driving and driving-related performance is reviewed here. Our review shows that talking on the phone, regardless of phone type, has negative impacts on performance especially in detecting and identifying events. Performance while using a hands-free phone was rarely found to be better than when using a handheld phone. Some studies found that drivers compensate for the deleterious effects of cell phone use when using a handheld phone but neglect to do so when using a hands-free phone. Current research does not support the decision to allow hands-free phone use while driving.
Design of a fiber-optic multiphoton microscopy handheld probe
Zhao, Yuan; Sheng, Mingyu; Huang, Lin; Tang, Shuo
2016-01-01
We have developed a fiber-optic multiphoton microscopy (MPM) system with handheld probe using femtosecond fiber laser. Here we present the detailed optical design and analysis of the handheld probe. The optical systems using Lightpath 352140 and 352150 as objective lens were analyzed. A custom objective module that includes Lightpath 355392 and two customized corrective lenses was designed. Their performances were compared by wavefront error, field curvature, astigmatism, F-θ error, and tolerance in Zemax simulation. Tolerance analysis predicted the focal spot size to be 1.13, 1.19 and 0.83 µm, respectively. Lightpath 352140 and 352150 were implemented in experiment and the measured lateral resolution was 1.22 and 1.3 µm, respectively, which matched with the prediction. MPM imaging by the handheld probe were conducted on leaf, fish scale and rat tail tendon. The MPM resolution can potentially be improved by the custom objective module. PMID:27699109
Design of a fiber-optic multiphoton microscopy handheld probe.
Zhao, Yuan; Sheng, Mingyu; Huang, Lin; Tang, Shuo
2016-09-01
We have developed a fiber-optic multiphoton microscopy (MPM) system with handheld probe using femtosecond fiber laser. Here we present the detailed optical design and analysis of the handheld probe. The optical systems using Lightpath 352140 and 352150 as objective lens were analyzed. A custom objective module that includes Lightpath 355392 and two customized corrective lenses was designed. Their performances were compared by wavefront error, field curvature, astigmatism, F-θ error, and tolerance in Zemax simulation. Tolerance analysis predicted the focal spot size to be 1.13, 1.19 and 0.83 µm, respectively. Lightpath 352140 and 352150 were implemented in experiment and the measured lateral resolution was 1.22 and 1.3 µm, respectively, which matched with the prediction. MPM imaging by the handheld probe were conducted on leaf, fish scale and rat tail tendon. The MPM resolution can potentially be improved by the custom objective module.
Becker, Brian C.; Yang, Sungwook; MacLachlan, Robert A.; Riviere, Cameron N.
2012-01-01
Injecting clot-busting drugs such as t-PA into tiny vessels thinner than a human hair in the eye is a challenging procedure, especially since the vessels lie directly on top of the delicate and easily damaged retina. Various robotic aids have been proposed with the goal of increasing safety by removing tremor and increasing precision with motion scaling. We have developed a fully handheld micromanipulator, Micron, that has demonstrated reduced tremor when cannulating porcine retinal veins in an “open sky” scenario. In this paper, we present work towards handheld robotic cannulation with the goal of vision-based virtual fixtures guiding the tip of the cannula to the vessel. Using a realistic eyeball phantom, we address sclerotomy constraints, eye movement, and non-planar retina. Preliminary results indicate a handheld micromanipulator aided by visual control is a promising solution to retinal vessel occlusion. PMID:24649479
Anthropometry, muscular strength and aerobic capacity up to 5 years after pediatric burns.
Disseldorp, Laurien M; Mouton, Leonora J; Van der Woude, Lucas H V; Van Brussel, Marco; Nieuwenhuis, Marianne K
2015-12-01
Physical functioning is of major importance after burns in many areas of life, in both the short and the long term. This cross-sectional study aimed to describe anthropometry, muscular strength and aerobic capacity in children and adolescents between 0.5-5 years after burns over 10% TBSA. Assessments took place in a mobile exercise lab. Demographics, burn characteristics and anthropometrics were recorded. Muscular strength in six muscle groups was measured using hand-held dynamometry and aerobic capacity was measured with a graded cardiopulmonary exercise test. Subjects' scores were compared with Dutch age- and gender-matched norm values and converted to Z-scores. The assessments were completed by 24 subjects with pediatric burns ranging from 10 to 41% TBSA and time after burn from 1 to 5 years (58.3% male; 6-18 years). On group level, no significant differences between the subjects' scores and norm values were found. No trends were seen indicating an effect of extent of burn or time after burn. Individually, eight subjects (33.3%), mostly aged 6 or 7, showed significantly low performance on at least one variable: seven for strength, one for aerobic capacity and one for both. Anthropometry, muscular strength and aerobic capacity are adequate in the majority of Dutch children and adolescents 1-5 years after 10-41% TBSA burns. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
McGiff, Thomas J; Danforth, Robert A; Herschaft, Edward E
2012-08-01
Clinical experience indicates that newly available portable hand-held x-ray units provide advantages compared to traditional fixed properly installed and operated x-ray units in dental radiography. However, concern that hand-held x-ray units produce higher operator doses than fixed x-ray units has caused regulatory agencies to mandate requirements for use of hand-held units that go beyond those recommended by the manufacturer and can discourage the use of this technology. To assess the need for additional requirements, a hand-held x-ray unit and a pair of manikins were used to measure the dose to a simulated operator under two conditions: exposures made according to the manufacturer's recommendations and exposures made according to manufacturer's recommendation except for the removal of the x-ray unit's protective backscatter shield. Dose to the simulated operator was determined using an array of personal dosimeters and a pair of pressurized ion chambers. The results indicate that the dose to an operator of this equipment will be less than 0.6 mSv y⁻¹ if the device is used according to the manufacturer's recommendations. This suggests that doses to properly trained operators of well-designed, hand-held dental x-ray units will be below 1.0 mSv y⁻¹ (2% of the annual occupational dose limit) even if additional no additional operational requirements are established by regulatory agencies. This level of annual dose is similar to those reported as typical dental personnel using fixed x-ray units and appears to satisfy the ALARA principal for this class of occupational exposures.
Yamaguchi, Masaki; Deguchi, Mitsuo; Wakasugi, Junichi; Ono, Shin; Takai, Noriyasu; Higashi, Tomoyuki; Mizuno, Yasufumi
2006-01-15
In order to realize a hand-held monitor of the sympathetic nervous system, we fabricated a completely automated analytical system for salivary amylase activity using a dry-chemistry system. This was made possible by the fabrication of a disposable test-strip equipped with built-in collecting and reagent papers and an automatic saliva transfer device. In order to cancel out the effects of variations in environmental temperature and pH of saliva, temperature- and pH-adjusted equations were experimentally determined, and each theoretical value was input into the memory of the hand-held monitor. Within a range of salivary amylase activity between 10 and 140 kU/l, the calibration curve for the hand-held monitor showed a coefficient with R(2)=0.97. Accordingly, it was demonstrated that the hand-held monitor enabled a user to automatically measure the salivary amylase activity with high accuracy with only 30 microl sample of saliva within a minute from collection to completion of the measurement. In order to make individual variations of salivary amylase activity negligible during driver fatigue assessment, a normalized equation was proposed. The normalized salivary amylase activity correlated with the mental and physical fatigue states. Thus, this study demonstrated that an excellent hand-held monitor with an algorithm for normalization of individuals' differences in salivary amylase activity, which could be easily and quickly used for evaluating the activity of the sympathetic nervous system at any time. Furthermore, it is suggested that the salivary amylase activity might be used as a better index for psychological research.
NASA Astrophysics Data System (ADS)
Weiss, Brian A.; Fronczek, Lisa; Morse, Emile; Kootbally, Zeid; Schlenoff, Craig
2013-05-01
Transformative Apps (TransApps) is a Defense Advanced Research Projects Agency (DARPA) funded program whose goal is to develop a range of militarily-relevant software applications ("apps") to enhance the operational-effectiveness of military personnel on (and off) the battlefield. TransApps is also developing a military apps marketplace to facilitate rapid development and dissemination of applications to address user needs by connecting engaged communities of endusers with development groups. The National Institute of Standards and Technology's (NIST) role in the TransApps program is to design and implement evaluation procedures to assess the performance of: 1) the various software applications, 2) software-hardware interactions, and 3) the supporting online application marketplace. Specifically, NIST is responsible for evaluating 50+ tactically-relevant applications operating on numerous Android™-powered platforms. NIST efforts include functional regression testing and quantitative performance testing. This paper discusses the evaluation methodologies employed to assess the performance of three key program elements: 1) handheld-based applications and their integration with various hardware platforms, 2) client-based applications and 3) network technologies operating on both the handheld and client systems along with their integration into the application marketplace. Handheld-based applications are assessed using a combination of utility and usability-based checklists and quantitative performance tests. Client-based applications are assessed to replicate current overseas disconnected (i.e. no network connectivity between handhelds) operations and to assess connected operations envisioned for later use. Finally, networked applications are assessed on handhelds to establish baselines of performance for when connectivity will be common usage.
Driver electronic device use in 2013.
DOT National Transportation Integrated Search
2015-04-01
The percentage of drivers text-messaging or visibly manipulating : hand-held devices increased from 1.5 percent in : 2012 to 1.7 percent in 2013; however, this was not a statistically : significant increase. Driver hand-held cell phone : use decrease...
Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children
Alving, K; Janson, C; Nordvall, L
2006-01-01
Background Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). Methods A total of 71 subjects (6–60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). Results Success rate was high (≥ 84%) in both devices for both adults and children. The subjects represented a FENO range of 8–147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. Conclusion The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children. The new hand-held device will enable the introduction of exhaled NO measurements into the primary health care. PMID:16626491
Stengel, Dirk; Bauwens, Kai; Walter, Martin; Köpfer, Thilo; Ekkernkamp, Axel
2004-03-01
Daily documentation and maintenance of medical record quality is a crucial issue in orthopaedic surgery. The purpose of the present study was to determine whether the introduction of a handheld computer could improve both the quantitative and qualitative aspects of medical records. A series of consecutive patients who were admitted for the first time to a thirty-six-bed orthopaedic ward of an academic teaching hospital for a planned operation or any other treatment of an acute injury or chronic condition were randomized to daily documentation of their clinical charts on a handheld computer or on conventional paper forms. The electronic documentation consisted of a specially designed software package on a handheld computer for bedside use with structured decision trees for examination, obtaining a history, and coding. In the control arm, chart notes were compiled on standard paper forms and were subsequently entered into the hospital's information system. The number of documented ICD (International Classification of Diseases) diagnoses was the primary end point for sample size calculations. All patient charts were reread by an expert panel consisting of two surgeons and the surgical quality assurance manager. These experts assigned quality ratings to the different documentation systems by scrutinizing the extent and accuracy of the patient histories and the physical findings as assessed by daily chart notes. Eighty patients were randomized to one of the two documentation arms, and seventy-eight (forty-seven men and thirty-one women) of them were eligible for final analysis. Documentation with the handheld computer increased the median number of diagnoses per patients from four to nine (p < 0.0001), but it produced some overcoding for false or redundant items. Documentation quality ratings improved significantly with the introduction of the handheld device (p < 0.01) with respect to the correct assessment of a patient's progress and translation into ICD diagnoses. Various learning curve effects were observed with different operators. Study physicians assigned slightly better practicability ratings to the handheld device. The preliminary data from this study suggest that handheld computers may improve the quality of hospital charts in orthopaedic surgery. Therapeutic study, Level I-1a (randomized controlled trial [significant difference]). See Instructions to Authors for a complete description of levels of evidence.
Saxagliptin Restores Vascular Mitochondrial Exercise Response in the Goto-Kakizaki Rat
Keller, Amy C.; Knaub, Leslie A.; Miller, Matthew W.; Birdsey, Nicholas; Klemm, Dwight J.
2015-01-01
Abstract: Cardiovascular disease risk and all-cause mortality are largely predicted by physical fitness. Exercise stimulates vascular mitochondrial biogenesis through endothelial nitric oxide synthase (eNOS), sirtuins, and PPARγ coactivator 1α (PGC-1α), a response absent in diabetes and hypertension. We hypothesized that an agent regulating eNOS in the context of diabetes could reconstitute exercise-mediated signaling to mitochondrial biogenesis. Glucagon-like peptide 1 (GLP-1) stimulates eNOS and blood flow; we used saxagliptin, an inhibitor of GLP-1 degradation, to test whether vascular mitochondrial adaptation to exercise in diabetes could be restored. Goto-Kakizaki (GK) rats, a nonobese, type 2 diabetes model, and Wistar controls were exposed to an 8-day exercise intervention with or without saxagliptin (10 mg·kg−1·d−1). We evaluated the impact of exercise and saxagliptin on mitochondrial proteins and signaling pathways in aorta. Mitochondrial protein expression increased with exercise in the Wistar aorta and decreased or remained unchanged in the GK animals. GK rats treated with saxagliptin plus exercise showed increased expression of mitochondrial complexes, cytochrome c, eNOS, nNOS, PGC-1α, and UCP3 proteins. Notably, a 3-week saxagliptin plus exercise intervention significantly increased running time in the GK rats. These data suggest that saxagliptin restores vascular mitochondrial adaptation to exercise in a diabetic rodent model and may augment the impact of exercise on the vasculature. PMID:25264749
Saxagliptin restores vascular mitochondrial exercise response in the Goto-Kakizaki rat.
Keller, Amy C; Knaub, Leslie A; Miller, Matthew W; Birdsey, Nicholas; Klemm, Dwight J; Reusch, Jane E B
2015-02-01
Cardiovascular disease risk and all-cause mortality are largely predicted by physical fitness. Exercise stimulates vascular mitochondrial biogenesis through endothelial nitric oxide synthase (eNOS), sirtuins, and PPARγ coactivator 1α (PGC-1α), a response absent in diabetes and hypertension. We hypothesized that an agent regulating eNOS in the context of diabetes could reconstitute exercise-mediated signaling to mitochondrial biogenesis. Glucagon-like peptide 1 (GLP-1) stimulates eNOS and blood flow; we used saxagliptin, an inhibitor of GLP-1 degradation, to test whether vascular mitochondrial adaptation to exercise in diabetes could be restored. Goto-Kakizaki (GK) rats, a nonobese, type 2 diabetes model, and Wistar controls were exposed to an 8-day exercise intervention with or without saxagliptin (10 mg·kg·d). We evaluated the impact of exercise and saxagliptin on mitochondrial proteins and signaling pathways in aorta. Mitochondrial protein expression increased with exercise in the Wistar aorta and decreased or remained unchanged in the GK animals. GK rats treated with saxagliptin plus exercise showed increased expression of mitochondrial complexes, cytochrome c, eNOS, nNOS, PGC-1α, and UCP3 proteins. Notably, a 3-week saxagliptin plus exercise intervention significantly increased running time in the GK rats. These data suggest that saxagliptin restores vascular mitochondrial adaptation to exercise in a diabetic rodent model and may augment the impact of exercise on the vasculature.
Monticone, Marco; Frizziero, Antonio; Rovere, Giancarlo; Vittadini, Filippo; Uliano, Domenico; LA Bruna, Silvano; Gatto, Renato; Nava, Claudia; Leggero, Vittorio; Masiero, Stefano
2016-06-01
It is debated whether intra-articular viscosupplementation with hyaluronic acid (HA) can lead to improvements in subjects with osteoarthritis (OA) undergoing physical and rehabilitative interventions. To assess the effects of intra-articular viscosupplementation on disability in subjects with OA undergoing physical and rehabilitative interventions. Information on pain and quality of life were also collected. The databases of PubMed, Medline, EMbase and CINAHL were searched for English language full-text randomized controlled trials comparing intra-articular viscosupplementation alone or associated with physical and rehabilitative interventions to viscosupplementation alone, shame treatment, waiting lists, and any type of rehabilitative interventions. Methodological quality of each study was assessed by using the Physiotherapy Evidence Database (PEDro) Scale. A total of 115 references were retrieved, and 8 studies were selected. Three trials compared HA injection and physical therapy in knee OA, with disability and pain improvements in all studies, and between-group differences in favor of physical therapy in two studies; two trials compared HA injection and home exercises in knee OA, with improvements in pain, disability and quality of life in all studies, without between-group differences; two trials compared HA injection plus physical therapy agents and exercises to exercises plus physical therapy agents in knee OA, with improvements in disability and pain in both studies, and between-group differences in favor of the inclusion HA in one study; one trial compared HA injection and home exercises in ankle OA, with improvements in disability and pain in both arms without between-group differences. Physical therapy agents seemed to have greater effects than intra-articular viscosupplementation on disability and pain. In the other cases both intra-articular viscosupplementation and physical and rehabilitative interventions seemed to be equally effective in improving disability, pain, and quality of life in subjects with knee and ankle OA. A treatment model associating intra-articular viscosupplementation to physical and rehabilitative interventions seems promising but more high quality RCTs are needed before it can be suggested.
Handheld Devices: Toward a More Mobile Campus.
ERIC Educational Resources Information Center
Fallon, Mary A. C.
2002-01-01
Offers an overview of the acceptance and use of handheld personal computing devices on campus that connect wirelessly to the campus network. Considers access; present and future software applications; uses in medial education; faculty training needs; and wireless technology issues. (Author/LRW)
Microwave Scanning System Correlations
2010-08-11
The follow equipment is needed for each of the individual scanning systems: Handheld Scanner Equipment list 1. Dell Netbook (with the...proper software installed by Evisive) 2. Bluetooth USB port transmitter 3. Handheld Probe 4. USB to mini-USB Converter (links camera to netbook
Field evaluation of a wireless handheld computer for railroad roadway workers.
DOT National Transportation Integrated Search
2009-01-31
This report is the third in a series describing the development and evaluation of a software application to facilitate communications for railroad roadway workers using a wireless handheld computer. The current prototype operated on a cell phone inte...
Field evaluation of a wireless handheld computer for railroad roadway workers
DOT National Transportation Integrated Search
2009-01-01
This report is the third in a series describing the development and evaluation of a software application to facilitate communications for railroad roadway workers using a wireless handheld computer. The current prototype operated on a cell phone inte...
NASA Astrophysics Data System (ADS)
Jehlicka, J.; Osterrothova, K.; Nedbalova, L.; Gunde-Cimerman, N.; Oren, A.
2014-06-01
Handheld Raman instrumentation with 532 nm lasers can be used to distinguish carotenoids of autotrophic microalgae, purple sulfur bacteria, halophilic Archaea and pigmented yeasts. Pigments are proposed as biomarkers for astrobiology of Mars.
Hand-held radiometer red and photographic infrared spectral measurements of agricultural crops
NASA Technical Reports Server (NTRS)
Tucker, C. J.; Fan, C. J.; Elgin, J. H., Jr.; Mcmurtrey, J. E., III
1978-01-01
Red and photographic infrared radiance data, collected under a variety of conditions at weekly intervals throughout the growing season using a hand-held radiometer, were used to monitor crop growth and development. The vegetation index transformation was used to effectively compensate for the different irradiational conditions encountered during the study period. These data, plotted against time, compared the different crops measured by comparing their green leaf biomass dynamics. This approach, based entirely upon spectral inputs, closely monitors crop growth and development and indicates the promise of ground-based hand-held radiometer measurements of crops.
Hand-held optical imager (Gen-2): improved instrumentation and target detectability
Gonzalez, Jean; DeCerce, Joseph; Erickson, Sarah J.; Martinez, Sergio L.; Nunez, Annie; Roman, Manuela; Traub, Barbara; Flores, Cecilia A.; Roberts, Seigbeh M.; Hernandez, Estrella; Aguirre, Wenceslao; Kiszonas, Richard
2012-01-01
Abstract. Hand-held optical imagers are developed by various researchers towards reflectance-based spectroscopic imaging of breast cancer. Recently, a Gen-1 handheld optical imager was developed with capabilities to perform two-dimensional (2-D) spectroscopic as well as three-dimensional (3-D) tomographic imaging studies. However, the imager was bulky with poor surface contact (∼30%) along curved tissues, and limited sensitivity to detect targets consistently. Herein, a Gen-2 hand-held optical imager that overcame the above limitations of the Gen-1 imager has been developed and the instrumentation described. The Gen-2 hand-held imager is less bulky, portable, and has improved surface contact (∼86%) on curved tissues. Additionally, the forked probe head design is capable of simultaneous bilateral reflectance imaging of both breast tissues, and also transillumination imaging of a single breast tissue. Experimental studies were performed on tissue phantoms to demonstrate the improved sensitivity in detecting targets using the Gen-2 imager. The improved instrumentation of the Gen-2 imager allowed detection of targets independent of their location with respect to the illumination points, unlike in Gen-1 imager. The developed imager has potential for future clinical breast imaging with enhanced sensitivity, via both reflectance and transillumination imaging. PMID:23224163
Lane, Shannon J; Heddle, Nancy M; Arnold, Emmy; Walker, Irwin
2006-01-01
Background Handheld computers are increasingly favoured over paper and pencil methods to capture data in clinical research. Methods This study systematically identified and reviewed randomized controlled trials (RCTs) that compared the two methods for self-recording and reporting data, and where at least one of the following outcomes was assessed: data accuracy; timeliness of data capture; and adherence to protocols for data collection. Results A comprehensive key word search of NLM Gateway's database yielded 9 studies fitting the criteria for inclusion. Data extraction was performed and checked by two of the authors. None of the studies included all outcomes. The results overall, favor handheld computers over paper and pencil for data collection among study participants but the data are not uniform for the different outcomes. Handheld computers appear superior in timeliness of receipt and data handling (four of four studies) and are preferred by most subjects (three of four studies). On the other hand, only one of the trials adequately compared adherence to instructions for recording and submission of data (handheld computers were superior), and comparisons of accuracy were inconsistent between five studies. Conclusion Handhelds are an effective alternative to paper and pencil modes of data collection; they are faster and were preferred by most users. PMID:16737535
User acquaintance with mobile interfaces.
Ehrler, Frederic; Walesa, Magali; Sarrey, Evelyne; Wipfli, Rolf; Lovis, Christian
2013-01-01
Handheld technology finds slowly its place in the healthcare world. Some clinicians already use intensively dedicated mobile applications to consult clinical references. However, handheld technology hasn't still broadly embraced to the core of the healthcare business, the hospitals. The weak penetration of handheld technology in the hospitals can be partly explained by the caution of stakeholders that must be convinced about the efficiency of these tools before going forward. In a domain where temporal constraints are increasingly strong, caregivers cannot loose time on playing with gadgets. All users are not comfortable with tactile manipulations and the lack of dedicated peripheral complicates entering data for novices. Stakeholders must be convinced that caregivers will be able to master handheld devices. In this paper, we make the assumption that the proper design of an interface may influence users' performances to record information. We are also interested to find out whether users increase their efficiency when using handheld tools repeatedly. To answer these questions, we have set up a field study to compare users' performances on three different user interfaces while recording vital signs. Some user interfaces were familiar to users, and others were totally innovative. Results showed that users' familiarity with smartphone influences their performances and that users improve their performances by repeating a task.
Alavi, Afsaneh; Sibbald, R Gary; Nabavizadeh, Reza; Valaei, Farnaz; Coutts, Pat; Mayer, Dieter
2015-12-01
To determine the accuracy of audible arterial foot signals with an audible handheld Doppler ultrasound for identification of significant peripheral arterial disease as a simple, quick, and readily available bedside screening tool. Two hundred consecutive patients referred to an interprofessional wound care clinic underwent audible handheld Doppler ultrasound of both legs. As a control and comparator, a formal bilateral lower leg vascular study including the calculation of Ankle Brachial Pressure Index and toe pressure (TP) was performed at the vascular lab. Diagnostic reliability of audible handheld Doppler ultrasound was calculated versus Ankle Brachial Pressure Index as the gold standard test. A sensitivity of 42.8%, a specificity of 97.5%, negative predictive value of 94.10%, positive predictive value of 65.22%, positive likelihood ratio of 17.52, and negative likelihood ratio of 0.59. The univariable logistic regression model had an area under the curve of 0.78. There was a statistically significant difference at the 5% level between univariable and multivariable area under the curves of the dorsalis pedis and posterior tibial models (p < 0.001). Audible handheld Doppler ultrasound proved to be a reliable, simple, rapid, and inexpensive bedside exclusion test of peripheral arterial disease in diabetic and nondiabetic patients. © The Author(s) 2015.
Portable oral cancer detection using a miniature confocal imaging probe with a large field of view
NASA Astrophysics Data System (ADS)
Wang, Youmin; Raj, Milan; McGuff, H. Stan; Bhave, Gauri; Yang, Bin; Shen, Ting; Zhang, Xiaojing
2012-06-01
We demonstrate a MEMS micromirror enabled handheld confocal imaging probe for portable oral cancer detection, where a comparatively large field of view (FOV) was generated through the programmable Lissajous scanning pattern of the MEMS micromirror. Miniaturized handheld MEMS confocal imaging probe was developed, and further compared with the desktop confocal prototype under clinical setting. For the handheld confocal imaging system, optical design simulations using CODE VR® shows the lateral and axial resolution to be 0.98 µm and 4.2 µm, where experimental values were determined to be 3 µm and 5.8 µm, respectively, with a FOV of 280 µm×300 µm. Fast Lissajous imaging speed up to 2 fps was realized with improved Labview and Java based real-time imaging software. Properties such as 3D imaging through autofocusing and mosaic imaging for extended lateral view (6 mm × 8 mm) were examined for carcinoma real-time pathology. Neoplastic lesion tissues of giant cell fibroma and peripheral ossifying fibroma, the fibroma inside the paraffin box and ex vivo gross tissues were imaged by the bench-top and handheld imaging modalities, and further compared with commercial microscope imaging results. The MEMS scanner-based handheld confocal imaging probe shows great promise as a potential clinical tool for oral cancer diagnosis and treatment.
NASA Astrophysics Data System (ADS)
Monroy, Guillermo L.; Won, Jungeun; Spillman, Darold R.; Dsouza, Roshan; Boppart, Stephen A.
2017-12-01
Since the inception of optical coherence tomography (OCT), advancements in imaging system design and handheld probes have allowed for numerous advancements in disease diagnostics and characterization of the structural and optical properties of tissue. OCT system developers continue to reduce form factor and cost, while improving imaging performance (speed, resolution, etc.) and flexibility for applicability in a broad range of fields, and nearly every clinical specialty. An extensive array of components to construct customized systems has also become available, with a range of commercial entities that produce high-quality products, from single components to full systems, for clinical and research use. Many advancements in the development of these miniaturized and portable systems can be linked back to a specific challenge in academic research, or a clinical need in medicine or surgery. Handheld OCT systems are discussed and explored for various applications. Handheld systems are discussed in terms of their relative level of portability and form factor, with mention of the supporting technologies and surrounding ecosystem that bolstered their development. Additional insight from our efforts to implement systems in several clinical environments is provided. The trend toward well-designed, efficient, and compact handheld systems paves the way for more widespread adoption of OCT into point-of-care or point-of-procedure applications in both clinical and commercial settings.
[Accuracy of three common optometry methods in examination of refraction in juveniles].
Su, Ting; Min, Xiaoshan; Liu, Shuangzhen; Li, Fengyun; Tan, Xingping; Zhong, Yanni; Deng, Shaoling
2016-02-01
To compare the results of the three methods of Suresight handheld autorefractor, table-mounted autorefractor and retinoscopy in examination of juveniles patients with or without cycloplegia. Firstly, 156 eyes of 78 juveniles (5 to 17 years old) were examined by using WelchAllyn Suresight handheld autorefractor and NIDEK ARK-510A table-mounted autorefractor with or without cycloplegia; secondly, retinoscopy was performed with cycloplegia. The spherical power measured by methods without cycloplegia were significantly greater than those measured with cycloplegia (P<0.05); without cycloplegia, there was no significant difference in spherical power, cylindrical power and cylindrical axis between Suresight handheld autorefractor and retinoscopy (P>0.05). These results were highly consistent, suggesting a tendency towards a short sight. However, the spherical power and cylindrical power measured by table-mounted autorefractor was significantly different (P<0.05); with cycloplegia, there was significant difference in spherical power between Suresight handheld autorefractor and retinoscopy (P<0.05). Cycloplegic retinoscopy is necessary for juvenile refraction examination. Under natural pupil situation, Suresight handheld autorefractor is better than table-mounted autorefractor, though both show a myopia tendency. Nevertheless, table-mounted autorefractor can be taken as a recommendation for the prescription of lens trial. As a strong reference for subjective optometry, retinoscopy should be the gold standard for measuring refractive errors.
New antiobesity agents: lorcaserin (Belviq) and phentermine/topiramate ER (Qsymia).
Shyh, Grace; Cheng-Lai, Angela
2014-01-01
Obesity is a risk factor for a wide range of conditions, including cardiovascular disease. Although lifestyle modifications remain the cornerstone for the management of obesity, pharmacologic agents may be a helpful addition to patients who have comorbidities and do not respond adequately to diet and exercise. Lorcaserin and phentermine/topiramate ER are 2 long-awaited agents, approved in 2012 for obesity management, 13 years since orlistat received US Food and Drug Administration approval in 1999. Lorcaserin is a serotonin agonist, whereas phentermine/topiramate is a combination of a sympathomimetic agent and an antiepileptic drug; both these agents have been shown to reduce weight significantly and improve cardiovascular and metabolic parameters, such as blood pressure, lipids, and HbA1C. This article reviews the pharmacology and clinical efficacy and safety of each of these agents. The differences among the three available agents for long-term management of obesity will also be examined.
DOT National Transportation Integrated Search
2015-01-01
The National Highway Traffic Safety Administration, the California Office of Traffic Safety, and the Delaware Highway Safety Office demonstrated State high-visibility enforcement (HVE) programs to reduce handheld phone use while driving. HVE was cond...
Driver electronic device use in 2008
DOT National Transportation Integrated Search
2009-09-01
The 2008 hand-held cell phone use rate translates into 812,000 vehicles being driven by someone using a hand-held cell phone at any given daylight moment.1 It also translates into an estimated 11 percent of the vehicles whose drivers were using some ...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-04
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-769] Certain Handheld Electronic Computing Devices, Related Software, and Components Thereof; Termination of the Investigation Based on... electronic computing devices, related software, and components thereof by reason of infringement of certain...
MS Mastracchio uses the hand-held laser rangefinder during STS-106
2000-09-18
STS106-320-014 (10 September 2000) --- Astronaut Richard A. Mastracchio, mission specialist, uses a handheld laser device on the aft flight deck of the Space Shuttle Atlantis to track the range of the International Space Station during rendezvous operations.
Tatone, Elise H; Gordon, Jessica L; LeBlanc, Stephen J; Duffield, Todd F
2015-05-15
To evaluate the use of a handheld device for measurement of β-hydroxybutyrate (BHBA) concentration to identify prepartum dairy cattle at risk of developing hyperketonemia during the first week after parturition. Cross-sectional study. Animals-210 prepartum dairy cows from 6 herds. A blood sample was collected from each cow 3 to 9 days before its expected calving date. β-Hydroxybutyrate concentration was immediately measured with a handheld device. Serum was harvested from the remaining sample and submitted to a laboratory for measurement of BHBA and nonesterified fatty acid (NEFA) concentrations. β-Hydroxybutyrate concentration determined with the handheld device was compared with that determined by laboratory methods. The association between prepartum BHBA concentration and the development of hyperketonemia (BHBA concentration, ≥ 1.2 mmol/L) during the first week after parturition was determined. The agreement between prepartum BHBA and NEFA concentrations for identification of cows at risk of developing postpartum hyperketonemia was evaluated. β-Hydroxybutyrate concentration determined by the handheld device was moderately correlated with that determined by laboratory methods. Cows with a prepartum BHBA concentration ≥ 0.6 mmol/L were 2.2 times as likely to develop hyperketonemia within 1 week after parturition as were cows with a prepartum BHBA concentration < 0.6 mmol/L. There was substantial agreement between prepartum BHBA and NEFA concentrations for identification of cows at risk of developing postpartum hyperketonemia. Results indicated the handheld device was a valid tool for measurement of BHBA concentration in prepartum dairy cattle, and measurement of prepartum BHBA concentration may be helpful for identifying cows at risk of developing postpartum hyperketonemia.
Monitoring of WEEE plastics in regards to brominated flame retardants using handheld XRF
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aldrian, Alexia, E-mail: alexia.aldrian@unileoben.ac.at; Ledersteger, Alfred, E-mail: a.ledersteger@saubermacher.at; Pomberger, Roland, E-mail: roland.pomberger@unileoben.ac.at
Highlights: • Specification of an empirical factor for conversion from bromine to PBB and PBDE. • The handheld XRF device was validated for this particular application. • A very large number of over 4600 pieces of monitor housings was analysed. • The recyclable fraction mounts up to 85% for TV but only 53% of PC waste plastics. • A high percentage of pieces with bromine contents of over 50,000 ppm was obtained. - Abstract: This contribution is focused on the on-site determination of the bromine content in waste electrical and electronic equipment (WEEE), in particular waste plastics from television setsmore » (TV) and personal computer monitors (PC) using a handheld X-ray fluorescence (XRF) device. The described approach allows the examination of samples in regards to the compliance with legal specifications for polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) directly after disassembling and facilitates the sorting out of plastics with high contents of brominated flame retardants (BFRs). In all, over 3000 pieces of black (TV) and 1600 pieces of grey (PC) plastic waste were analysed with handheld XRF technique for this study. Especially noticeable was the high percentage of pieces with a bromine content of over 50,000 ppm for TV (7%) and PC (39%) waste plastics. The applied method was validated by comparing the data of handheld XRF with results obtained by GC–MS. The results showed the expected and sufficiently accurate correlation between these two methods. It is shown that handheld XRF technique is an effective tool for fast monitoring of large volumes of WEEE plastics in regards to BFRs for on-site measurements.« less
The accuracy of a hand-held navigation system in total knee arthroplasty.
Loh, Bryan; Chen, Jerry Yongqiang; Yew, Andy Khye Soon; Pang, Hee Nee; Tay, Darren Keng Jin; Chia, Shi-Lu; Lo, Ngai Nung; Yeo, Seng Jin
2017-03-01
This study aims to evaluate the effectiveness of a new hand-held navigation system. The authors of this study hypothesize that this navigation system will improve overall lower limb alignment and implant placement without causing a delay in surgery. Two hundred consecutive patients diagnosed with tricompartmental osteoarthritis and underwent total knee arthroplasty by a senior surgeon were included in this study. One hundred patients underwent TKA using the hand-held navigation system, while the other 100 patients underwent TKA using the conventional technique. The primary outcomes of this study were the overall alignment of the lower limb and the position of the components. This was determined radiologically using the: (1) Hip-Knee-Ankle angle (HKA) for lower limb alignment; (2) Coronal Femoral-Component angle (CFA); and (3) Coronal Tibia-Component angle (CTA) for component position. Normal alignment was taken as 180° ± 3° for the HKA and 90° ± 3° for both the CFA and CTA. For the CFA, the proportion of outliers was 7 and 17% in the hand-held navigation and conventional group, respectively (p = 0.030). For the HKA and CTA, there was no difference in the proportion of outliers between the two groups. The duration of surgery was 73 ± 9 min and 87 ± 15 min in the hand-held navigation and conventional group, respectively (p < 0.001). This hand-held navigation system is an effective intraoperative tool for reducing the proportion of outliers for femoral implant placement as well as the duration of surgery. The authors conclude that it can be considered for use to check femoral implant placement intra-operatively. III.
Zühlke, Liesl J; Engel, Mark E; Nkepu, Simpiwe; Mayosi, Bongani M
2016-08-01
Introduction Echocardiography is the diagnostic test of choice for latent rheumatic heart disease. The utility of echocardiography for large-scale screening is limited by high cost, complex diagnostic protocols, and time to acquire multiple images. We evaluated the performance of a brief hand-held echocardiography protocol and computer-assisted auscultation in detecting latent rheumatic heart disease with or without pathological murmur. A total of 27 asymptomatic patients with latent rheumatic heart disease based on the World Heart Federation criteria and 66 healthy controls were examined by standard cardiac auscultation to detect pathological murmur. Hand-held echocardiography using a focussed protocol that utilises one view - that is, the parasternal long-axis view - and one measurement - that is, mitral regurgitant jet - and a computer-assisted auscultation utilising an automated decision tool were performed on all patients. The sensitivity and specificity of computer-assisted auscultation in latent rheumatic heart disease were 4% (95% CI 1.0-20.4%) and 93.7% (95% CI 84.5-98.3%), respectively. The sensitivity and specificity of the focussed hand-held echocardiography protocol for definite rheumatic heart disease were 92.3% (95% CI 63.9-99.8%) and 100%, respectively. The test reliability of hand-held echocardiography was 98.7% for definite and 94.7% for borderline disease, and the adjusted diagnostic odds ratios were 1041 and 263.9 for definite and borderline disease, respectively. Computer-assisted auscultation has extremely low sensitivity but high specificity for pathological murmur in latent rheumatic heart disease. Focussed hand-held echocardiography has fair sensitivity but high specificity and diagnostic utility for definite or borderline rheumatic heart disease in asymptomatic patients.
Ge, Jiajia; Zhu, Banghe; Regalado, Steven; Godavarty, Anuradha
2008-01-01
Hand-held based optical imaging systems are a recent development towards diagnostic imaging of breast cancer. To date, all the hand-held based optical imagers are used to perform only surface mapping and target localization, but are not capable of demonstrating tomographic imaging. Herein, a novel hand-held probe based optical imager is developed towards three-dimensional (3-D) optical tomography studies. The unique features of this optical imager, which primarily consists of a hand-held probe and an intensified charge coupled device detector, are its ability to; (i) image large tissue areas (5×10 sq. cm) in a single scan, (ii) perform simultaneous multiple point illumination and collection, thus reducing the overall imaging time; and (iii) adapt to varying tissue curvatures, from a flexible probe head design. Experimental studies are performed in the frequency domain on large slab phantoms (∼650 ml) using fluorescence target(s) under perfect uptake (1:0) contrast ratios, and varying target depths (1–2 cm) and X-Y locations. The effect of implementing simultaneous over sequential multiple point illumination towards 3-D tomography is experimentally demonstrated. The feasibility of 3-D optical tomography studies has been demonstrated for the first time using a hand-held based optical imager. Preliminary fluorescence-enhanced optical tomography studies are able to reconstruct 0.45 ml target(s) located at different target depths (1–2 cm). However, the depth recovery was limited as the actual target depth increased, since only reflectance measurements were acquired. Extensive tomography studies are currently carried out to determine the resolution and performance limits of the imager on flat and curved phantoms. PMID:18697559
DOE Office of Scientific and Technical Information (OSTI.GOV)
Younkin, James R; Kuhn, Michael J; Gradle, Colleen
New Brunswick Laboratory (NBL) has a numerous inventory containing thousands of plutonium and uranium certified reference materials. The current manual inventory process is well established but is a lengthy process which requires significant oversight and double checking to ensure correctness. Oak Ridge National Laboratory has worked with NBL to develop and deploy a new inventory system which utilizes handheld computers with barcode scanners and radio frequency identification (RFID) readers termed the Tagged Item Inventory System (TIIS). Certified reference materials are identified by labels which incorporate RFID tags and barcodes. The label printing process and RFID tag association process are integratedmore » into the main desktop software application. Software on the handheld computers syncs with software on designated desktop machines and the NBL inventory database to provide a seamless inventory process. This process includes: 1) identifying items to be inventoried, 2) downloading the current inventory information to the handheld computer, 3) using the handheld to read item and location labels, and 4) syncing the handheld computer with a designated desktop machine to analyze the results, print reports, etc. The security of this inventory software has been a major concern. Designated roles linked to authenticated logins are used to control access to the desktop software while password protection and badge verification are used to control access to the handheld computers. The overall system design and deployment at NBL will be presented. The performance of the system will also be discussed with respect to a small piece of the overall inventory. Future work includes performing a full inventory at NBL with the Tagged Item Inventory System and comparing performance, cost, and radiation exposures to the current manual inventory process.« less
Ge, Jiajia; Zhu, Banghe; Regalado, Steven; Godavarty, Anuradha
2008-07-01
Hand-held based optical imaging systems are a recent development towards diagnostic imaging of breast cancer. To date, all the hand-held based optical imagers are used to perform only surface mapping and target localization, but are not capable of demonstrating tomographic imaging. Herein, a novel hand-held probe based optical imager is developed towards three-dimensional (3-D) optical tomography studies. The unique features of this optical imager, which primarily consists of a hand-held probe and an intensified charge coupled device detector, are its ability to; (i) image large tissue areas (5 x 10 sq. cm) in a single scan, (ii) perform simultaneous multiple point illumination and collection, thus reducing the overall imaging time; and (iii) adapt to varying tissue curvatures, from a flexible probe head design. Experimental studies are performed in the frequency domain on large slab phantoms (approximately 650 ml) using fluorescence target(s) under perfect uptake (1:0) contrast ratios, and varying target depths (1-2 cm) and X-Y locations. The effect of implementing simultaneous over sequential multiple point illumination towards 3-D tomography is experimentally demonstrated. The feasibility of 3-D optical tomography studies has been demonstrated for the first time using a hand-held based optical imager. Preliminary fluorescence-enhanced optical tomography studies are able to reconstruct 0.45 ml target(s) located at different target depths (1-2 cm). However, the depth recovery was limited as the actual target depth increased, since only reflectance measurements were acquired. Extensive tomography studies are currently carried out to determine the resolution and performance limits of the imager on flat and curved phantoms.
Kalcsits, Lee A.
2016-01-01
Calcium and potassium are essential for cell signaling, ion homeostasis and cell wall strength in plants. Unlike nutrients such as nitrogen and potassium, calcium is immobile in plants. Localized calcium deficiencies result in agricultural losses; particularly for fleshy horticultural crops in which elemental imbalances in fruit contribute to the development of physiological disorders such as bitter pit in apple and cork spot in pear. Currently, elemental analysis of plant tissue is destructive, time consuming and costly. This is a limitation for nutrition studies related to calcium in plants. Handheld portable x-ray fluorescence (XRF) can be used to non-destructively measure elemental concentrations. The main objective was to test if handheld XRF can be used for semi-quantitative calcium and potassium analysis of in-tact apple and pear. Semi-quantitative measurements for individual fruit were compared to results obtained from traditional lab analysis. Here, we observed significant correlations between handheld XRF measurements of calcium and potassium and concentrations determined using MP-AES lab analysis. Pearson correlation coefficients ranged from 0.73 and 0.97. Furthermore, measuring apple and pear using handheld XRF identified spatial variability in calcium and potassium concentrations on the surface of individual fruit. This variability may contribute to the development of localized nutritional imbalances. This highlights the importance of understanding spatial and temporal variability in elemental concentrations in plant tissue. Handheld XRF is a relatively high-throughput approach for measuring calcium and potassium in plant tissue. It can be used in conjunction with traditional lab analysis to better understand spatial and temporal patterns in calcium and potassium uptake and distribution within an organ, plant or across the landscape. PMID:27092160
Handheld computers for self-administered sensitive data collection: A comparative study in Peru
Bernabe-Ortiz, Antonio; Curioso, Walter H; Gonzales, Marco A; Evangelista, Wilfredo; Castagnetto, Jesus M; Carcamo, Cesar P; Hughes, James P; Garcia, Patricia J; Garnett, Geoffrey P; Holmes, King K
2008-01-01
Background Low-cost handheld computers (PDA) potentially represent an efficient tool for collecting sensitive data in surveys. The goal of this study is to evaluate the quality of sexual behavior data collected with handheld computers in comparison with paper-based questionnaires. Methods A PDA-based program for data collection was developed using Open-Source tools. In two cross-sectional studies, we compared data concerning sexual behavior collected with paper forms to data collected with PDA-based forms in Ancon (Lima). Results The first study enrolled 200 participants (18–29 years). General agreement between data collected with paper format and handheld computers was 86%. Categorical variables agreement was between 70.5% and 98.5% (Kappa: 0.43–0.86) while numeric variables agreement was between 57.1% and 79.8% (Spearman: 0.76–0.95). Agreement and correlation were higher in those who had completed at least high school than those with less education. The second study enrolled 198 participants. Rates of responses to sensitive questions were similar between both kinds of questionnaires. However, the number of inconsistencies (p = 0.0001) and missing values (p = 0.001) were significantly higher in paper questionnaires. Conclusion This study showed the value of the use of handheld computers for collecting sensitive data, since a high level of agreement between paper and PDA responses was reached. In addition, a lower number of inconsistencies and missing values were found with the PDA-based system. This study has demonstrated that it is feasible to develop a low-cost application for handheld computers, and that PDAs are feasible alternatives for collecting field data in a developing country. PMID:18366687
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Weiying; Ge, Xiaoxiao; Tang, Yong
A nanoparticle-based fluorescence immunochromatographic test strip (FITS) coupled with a hand-held detector for highly selective and sensitive detection of phosphorylated acetylcholinesterase (AChE), an exposure biomarker of organophosphate (OP) pesticides and nerve agents, is reported. In this approach, OP-AChE adducts were selectively captured by quantum dot-tagged anti-AChE antibodies (Qdot-anti-AChE) and zirconia nanoparticles (ZrO2 NPs). The sandwich-like immunoreactions were performed among the Qdot-anti-AChE, OP-AChE and ZrO2 NPs to form Qdot-anti-AChE/OP-AChE/ZrO2 complex, which was detected by recording the fluorescence intensity of Qdot captured on the test line. Paraoxon was used as the model OP pesticides. Under optimal conditions, this portable FITS immunosensor demonstratesmore » a highly linear absorption response over the range of 0.01 nM to 10 nM OP-AChE, with a detection limit of 4 pM, coupled with a good reproducibility. Moreover, the FITS immunosensor has been validated with OP-AChE spiked human plasma samples. This is the first report on the development of ZrO2 NPs-based FITS for detection of OP-AChE adduct. The FITS immunosensor provides a sensitive and low-cost sensing platform for on-site screening/evaluating OP pesticides and nerve agents poisoning.« less
Neurosurgery contact handheld probe based on sapphire shaped crystal
NASA Astrophysics Data System (ADS)
Shikunova, I. A.; Stryukov, D. O.; Rossolenko, S. N.; Kiselev, A. M.; Kurlov, V. N.
2017-01-01
A handheld contact probe based on sapphire shaped crystal is developed for intraoperative spectrally-resolved optical diagnostics, laser coagulation and aspiration of malignant brain tissue. The technology was integrated into the neurosurgical workflow for intraoperative real-time identification and removing of invasive brain cancer.
DETAIL VIEW OF A HANDHELD BUMPER, USED TO AID IN ...
DETAIL VIEW OF A HANDHELD BUMPER, USED TO AID IN POSITIONING THE ORBITER DURING STACKING PROCEDURES - Cape Canaveral Air Force Station, Launch Complex 39, Vehicle Assembly Building, VAB Road, East of Kennedy Parkway North, Cape Canaveral, Brevard County, FL
Code of Federal Regulations, 2012 CFR
2012-10-01
... APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-2 Type. (a) Handheld rocket-propelled parachute red flare distress signals specified by this subpart... fired from the hand to provide a rocket-propelled parachute red flare distress signal. (b) [Reserved] ...
Code of Federal Regulations, 2014 CFR
2014-10-01
... APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-2 Type. (a) Handheld rocket-propelled parachute red flare distress signals specified by this subpart... fired from the hand to provide a rocket-propelled parachute red flare distress signal. (b) [Reserved] ...
Code of Federal Regulations, 2010 CFR
2010-10-01
... APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-2 Type. (a) Handheld rocket-propelled parachute red flare distress signals specified by this subpart... fired from the hand to provide a rocket-propelled parachute red flare distress signal. (b) [Reserved] ...
Code of Federal Regulations, 2011 CFR
2011-10-01
... APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-2 Type. (a) Handheld rocket-propelled parachute red flare distress signals specified by this subpart... fired from the hand to provide a rocket-propelled parachute red flare distress signal. (b) [Reserved] ...
Code of Federal Regulations, 2013 CFR
2013-10-01
... APPROVAL LIFESAVING EQUIPMENT Hand-Held Rocket-Propelled Parachute Red Flare Distress Signals § 160.036-2 Type. (a) Handheld rocket-propelled parachute red flare distress signals specified by this subpart... fired from the hand to provide a rocket-propelled parachute red flare distress signal. (b) [Reserved] ...
NASA Technical Reports Server (NTRS)
Young, K. E.; Hodges, K. V.; Evans, C. A.
2012-01-01
While large-footprint X-ray fluorescence (XRF) instruments are reliable providers of elemental information about geologic samples, handheld XRF instruments are currently being developed that enable the collection of geochemical data in the field in short time periods (approx.60 seconds) [1]. These detectors are lightweight (1.3kg) and can provide elemental abundances of major rock forming elements heavier than Na. While handheld XRF detectors were originally developed for use in mining, we are working with commercially available instruments as prototypes to explore how portable XRF technology may enable planetary field science [2,3,4]. If an astronaut or robotic explorer visited another planetary surface, the ability to obtain and evaluate geochemical data in real-time would be invaluable, especially in the high-grading of samples to determine which should be returned to Earth. We present our results on the evaluation of handheld XRF technology as a geochemical tool in the context of planetary exploration.
A new perspective of the hippocampus in the origin of exercise-brain interactions.
Rendeiro, Catarina; Rhodes, Justin S
2018-07-01
Exercising regularly is a highly effective strategy for maintaining cognitive health throughout the lifespan. Over the last 20 years, many molecular, physiological and structural changes have been documented in response to aerobic exercise training in humans and animals, particularly in the hippocampus. However, how exercise produces such neurological changes remains elusive. A recent line of investigation has suggested that muscle-derived circulating factors cross into the brain and may be the key agents driving enhancement in synaptic plasticity and hippocampal neurogenesis from aerobic exercise. Alternatively, or concurrently, the signals might originate from within the brain itself. Physical activity also produces instantaneous and robust neuronal activation of the hippocampal formation and the generation of theta oscillations which are closely correlated with the force of movements. The repeated acute activation of the hippocampus during physical movement is likely critical for inducing the long-term neuroadaptations from exercise. Here we review the evidence which establishes the association between physical movement and hippocampal neuronal activation and discuss implications for long-term benefits of physical activity on brain function.
PubMed on Tap: discovering design principles for online information delivery to handheld computers.
Hauser, Susan E; Demner-Fushman, Dina; Ford, Glenn; Thoma, George R
2004-01-01
Online access to biomedical information from handheld computers will be a valuable adjunct to other popular medical applications if information delivery systems are designed with handheld computers in mind. The goal of this project is to discover design principles to facilitate practitioners' access to online medical information at the point-of-care. A prototype system was developed to serve as a testbed for this research. Using the testbed, an initial evaluation has yielded several user interface design principles. Continued research is expected to discover additional user interface design principles as well as guidelines for results organization and system performance
Handheld optical-resolution photoacoustic microscopy
NASA Astrophysics Data System (ADS)
Lin, Li; Zhang, Pengfei; Xu, Song; Shi, Junhui; Li, Lei; Yao, Junjie; Wang, Lidai; Zou, Jun; Wang, Lihong V.
2017-04-01
Optical-resolution photoacoustic microscopy (OR-PAM) offers label-free in vivo imaging with high spatial resolution by acoustically detecting optical absorption contrasts via the photoacoustic effect. We developed a compact handheld OR-PAM probe for fast photoacoustic imaging. Different from benchtop microscopes, the handheld probe provides flexibility in imaging various anatomical sites. Resembling a cup in size, the probe uses a two-axis water-immersible microelectromechanical system mirror to scan both the illuminating optical beam and resultant acoustic beam. The system performance was tested in vivo by imaging the capillary bed in a mouse ear and both the capillary bed and a mole on a human volunteer.
Engineering issues for hand-held sensing devices, with examples
NASA Astrophysics Data System (ADS)
Freiwald, David A.; Freiwald, Joyce
1994-03-01
It is now U.S. defense policy that there will be no new platform starts. The emphasis for platforms will be on O&M cost reduction, life-extension improvements, and force-multiplier- device upgrades. There is also an increasing emphasis on hand-held force-multiplier devices for individuals, which is the focus of this paper. Engineering issues include operations analysis, weight, cube, cost, prime power, ease of use, data storage, reliability, fault tolerance, data communications and human factors. Two examples of hand-held devices are given. Applications include USMC, Army, SOCOM, DEA, FBI, SS, Border Patrol and others. Barriers to adoption of such technology are also discussed.
Sayar, Melike; Karakuş, Erman; Güner, Tuğrul; Yildiz, Busra; Yildiz, Umit Hakan; Emrullahoğlu, Mustafa
2018-03-02
A boron-dipyrromethene (BODIPY)-based fluorescent probe with a phosgene-specific reactive motif shows remarkable selectivity toward phosgene, in the presence of which the nonfluorescent dye rapidly transforms into a new structure and induces a fluorescent response clearly observable to the naked eye under ultraviolet light. Given that dynamic, a prototypical handheld phosgene detector with a promising sensing capability that expedites the detection of gaseous phosgene without sophisticated instrumentation was developed. The proposed method using the handheld detector involves a rapid response period suitable for issuing early warnings during emergency situations. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Handheld detector using NIR for bottled liquid explosives
NASA Astrophysics Data System (ADS)
Itozaki, Hideo; Sato-Akaba, Hideo
2014-10-01
A handheld bottle checker for detection of liquid explosives is developed using near infrared technology. In order to make it compact, a LED light was used as a light source and a novel circuit board was developed for the device control instead of using a PC. This enables low power consumption and this handheld detector can be powered by a Li-ion battery without an AC power supply. This checker works well to analyze liquids, even using limited bandwidth of NIR by the LED. It is expected that it can be applied not only to airport security but also to wider applications because of its compactness and portability.
Hypnosis for exercise-induced asthma.
Ben-Zvi, Z; Spohn, W A; Young, S H; Kattan, M
1982-04-01
Hypnosis has been used for many years in the treatment of asthma, but studies of its usefulness have been controversial. We assessed the efficacy of hypnosis in attenuating exercise-induced asthma (EIA) in 10 stable asthmatics. The subjects ran on a treadmill while mouth breathing for 6 min on 5 different days. Pulmonary mechanics were measured before and after each challenge. Two control exercise challenges resulted in a reproducible decrease in forced expiratory volume in one second (FEV1). On 2 other days, saline or cromolyn by nebulization was given in a double-blind manner with the suggestion that these agents would prevent EIA. Hypnosis prior to exercise resulted in a 15.9% decrease in FEV1 compared with a 31.8% decrease on the control days (p less than 0.001). Pretreatment with cromolyn resulted in a 7.6% decrease in FEV1. We conclude that hypnosis can alter the magnitude of a pathophysiologic process, namely, the bronchospasm after exercise in patients with asthma.
Przyborowski, Kamil; Wojewoda, Marta; Sitek, Barbara; Zakrzewska, Agnieszka; Kij, Agnieszka; Wandzel, Krystyna; Zoladz, Jerzy Andrzej; Chlopicki, Stefan
2015-01-01
1-Methylnicotinamide (MNA), which was initially considered to be a biologically inactive endogenous metabolite of nicotinamide, has emerged as an anti-thrombotic and anti-inflammatory agent with the capacity to release prostacyclin (PGI2). In the present study, we characterized the effects of MNA on exercise capacity and the endothelial response to exercise in diabetic mice. Eight-week-old db/db mice were untreated or treated with MNA for 4 weeks (100 mg·kg-1), and their exercise capacity as well as NO- and PGI2-dependent response to endurance running were subsequently assessed. MNA treatment of db/db mice resulted in four-fold and three-fold elevation of urine concentrations of MNA and its metabolites (Met-2PY + Met-4PY), respectively (P<0.01), but did not affect HbA1c concentration, fasting glucose concentration or lipid profile. However, insulin sensitivity was improved (P<0.01). In MNA-treated db/db mice, the time to fatigue for endurance exercise was significantly prolonged (P<0.05). Post-exercise Δ6-keto-PGF1α (difference between mean concentration in the sedentary and exercised groups) tended to increase, and post-exercise leukocytosis was substantially reduced in MNA-treated animals. In turn, the post-exercise fall in plasma concentration of nitrate was not affected by MNA. In conclusion, we demonstrated for the first time that MNA improves endurance exercise capacity in mice with diabetes, and may also decrease the cardiovascular risk of exercise.
Handheld Computers in Education: An Industry Perspective
ERIC Educational Resources Information Center
van 't Hooft, Mark; Vahey, Philip
2007-01-01
Five representatives from the mobile computing industry provide their perspectives on handhelds in education. While some of their ideas differ, they all agree on the importance of staff development, appropriate curriculum development, and teacher support to create the kinds of personalized learning environments that mobile devices make possible.
49 CFR 40.391 - What is the scope of a PIE?
Code of Federal Regulations, 2010 CFR
2010-10-01
... reason to know of, approved, or acquiesced in such conduct. The individual's acceptance of benefits... necessarily applies to all its operations. Example 5 to § 40.391. Service Agent X, by exercising reasonably...
Use of a hand-held meter for detecting subclinical ketosis in dairy cows.
Voyvoda, Huseyin; Erdogan, Hasan
2010-12-01
The Optium Xceed is a new hand-held meter for determining blood β-hydroxybutyrate (BHBA) and glucose in human medicine. The objective of this study was to compare BHBA and glucose results obtained using the hand-held meter with those results made with a laboratory method and to evaluate its usefulness as a cowside test in the diagnosis of subclinical ketosis (SCK) in dairy cows. Seventy-eight blood samples from clinically healthy Holstein cows between 5 and 60 days post-calving were analysed. BHBA and glucose values were significantly higher with the hand-held meter versus laboratory methods. Correlation coefficients (r) for BHBA and glucose with the Optium Xceed versus laboratory methods were 0.97 and 0.63, respectively. Based on Bland-Altman plot and Passing-Bablok regression, agreement between two methods was good for BHBA but the agreement for glucose was only fair. When SCK was defined as plasma BHBA levels ≥ 1200 μmol/L, the sensitivity and specificity of the hand-held meter ketone testing in determining SCK were 85% and 94%, respectively. Raising the threshold of the laboratory method to ≥ 1400 μmol/L, the sensitivity and specificity incremented to 0.90 and 0.98, respectively. In conclusion, the blood ketone-monitoring device can be used as a rapid and reliable diagnostic test to detect SCK under field conditions. Copyright © 2010 Elsevier Ltd. All rights reserved.
Handheld technology acceptance in radiologic science education and training programs
NASA Astrophysics Data System (ADS)
Powers, Kevin Jay
The purpose of this study was to explore the behavioral intention of directors of educational programs in the radiologic sciences to adopt handheld devices to aid in managing student clinical data. Handheld devices were described to participants as a technology representing a class of mobile electronic devices including, but not limited to, personal digital assistants such as a Palm TX, Apple iPod Touch, Apple iPad or Hewlett Packard iPaq, and cellular or smartphones with third generation mobile capabilities such as an Apple iPhone, Blackberry or Android device. The study employed a non-experimental, cross-sectional survey design to determine the potential of adopting handheld technologies based on the constructs of Davis's (1989) Technology Acceptance Model. An online self-report questionnaire survey instrument was used to gather study data from 551 entry level radiologic science programs specializing in radiography, radiation therapy, nuclear medicine and medical sonography. The study design resulted in a single point in time assessment of the relationship between the primary constructs of the Technology Acceptance Model: perceived usefulness and perceived ease of use, and the behavioral intention of radiography program directors to adopt the information technology represented by hand held devices. Study results provide justification for investing resources to promote the adoption of mobile handheld devices in radiologic science programs and study findings serve as a foundation for further research involving technology adoption in the radiologic sciences.
NASA Astrophysics Data System (ADS)
LaRocca, Francesco; Nankivil, Derek; Keller, Brenton; Farsiu, Sina; Izatt, Joseph A.
2017-02-01
Handheld optical coherence tomography (OCT) systems facilitate imaging of young children, bedridden subjects, and those with less stable fixation. Smaller and lighter OCT probes allow for more efficient imaging and reduced operator fatigue, which is critical for prolonged use in either the operating room or neonatal intensive care unit. In addition to size and weight, the imaging speed, image quality, field of view, resolution, and focus correction capability are critical parameters that determine the clinical utility of a handheld probe. Here, we describe an ultra-compact swept source (SS) OCT handheld probe weighing only 211 g (half the weight of the next lightest handheld SSOCT probe in the literature) with 20.1 µm lateral resolution, 7 µm axial resolution, 102 dB peak sensitivity, a 27° x 23° field of view, and motorized focus adjustment for refraction correction between -10 to +16 D. A 2D microelectromechanical systems (MEMS) scanner, a converging beam-at-scanner telescope configuration, and an optical design employing 6 different custom optics were used to minimize device size and weight while achieving diffraction limited performance throughout the system's field of view. Custom graphics processing unit (GPU)-accelerated software was used to provide real-time display of OCT B-scans and volumes. Retinal images were acquired from adult volunteers to demonstrate imaging performance.
Hand-Held Self-Maneuvering Unit to be used during EVA on Gemini 4
1965-06-02
Hand-Held Self-Maneuvering Unit to be used during extravehicular activity (EVA) on Gemini 4 flight. It is an integral unit that contains its own high pressure metering valves and nozzles required to produce controlled thrust. A camera is mounted on the front of the unit.
49 CFR 392.82 - Using a hand-held mobile telephone.
Code of Federal Regulations, 2012 CFR
2012-10-01
...) Definitions. For the purpose of this section only, driving means operating a commercial motor vehicle on a... SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS DRIVING OF.... (a)(1) No driver shall use a hand-held mobile telephone while driving a CMV. (2) No motor carrier...
49 CFR 392.82 - Using a hand-held mobile telephone.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Definitions. For the purpose of this section only, driving means operating a commercial motor vehicle on a... SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS DRIVING OF.... (a)(1) No driver shall use a hand-held mobile telephone while driving a CMV. (2) No motor carrier...
49 CFR 392.82 - Using a hand-held mobile telephone.
Code of Federal Regulations, 2013 CFR
2013-10-01
...) Definitions. For the purpose of this section only, driving means operating a commercial motor vehicle on a... SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS DRIVING OF.... (a)(1) No driver shall use a hand-held mobile telephone while driving a CMV. (2) No motor carrier...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-08
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-667; Investigation No. 337-TA-673] In the Matter of Certain Electronic Devices, Including Handheld Wireless Communications Devices; Notice of... Entirety AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that...
30 CFR 56.12033 - Hand-held electric tools.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...
30 CFR 56.12033 - Hand-held electric tools.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...
30 CFR 56.12033 - Hand-held electric tools.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...
30 CFR 56.12033 - Hand-held electric tools.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...
30 CFR 56.12033 - Hand-held electric tools.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...
A Context-Aware Ubiquitous Learning Environment for Language Listening and Speaking
ERIC Educational Resources Information Center
Liu, T.-Y.
2009-01-01
This paper reported the results of a study that aimed to construct a sensor and handheld augmented reality (AR)-supported ubiquitous learning (u-learning) environment called the Handheld English Language Learning Organization (HELLO), which is geared towards enhancing students' language learning. The HELLO integrates sensors, AR, ubiquitous…
USDA-ARS?s Scientific Manuscript database
Current meat inspection in slaughter plants, for food safety and quality attributes including potential fecal contamination, is conducted through by visual examination human inspectors. A handheld fluorescence-based imaging device (HFID) was developed to be an assistive tool for human inspectors by ...
Handheld Technology as a Supplemental Tool for Elementary General Music Education
ERIC Educational Resources Information Center
Carlisle, Katie
2014-01-01
This article argues that "The Eclectic Curriculum in American Music Education" warrants consideration within current elementary general music education contexts. One way to consider this foundational text is in terms of how technology can serve as a tool for enriching instructional approaches. While handheld technology use within these…
ERIC Educational Resources Information Center
Scribner-MacLean, Michelle; Nikonchuk, Andrew; Kaplo, Patrick; Wall, Michael
2006-01-01
Science educators are often among the first to use emerging technologies in the classroom and laboratory. For the technologically savvy science teacher, the handheld computer is a terrific tool. A handheld computer is a portable electronic device that helps organize (via calendars, contact lists, to-do lists) and integrate electronic data…
Survey reveals public open to ban on hand-held cell phone use and texting.
DOT National Transportation Integrated Search
2013-01-01
A study performed by the Bureau of Transportation Statistics : (BTS) reveals that the public is open to a ban on : hand-held cell phone use while driving. The study is based : on data from 2009s Omnibus Household Survey (OHS), : which is administe...
78 FR 27441 - NIJ Evaluation of Hand-Held Cell Phone Detector Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-10
... Hand-Held Cell Phone Detector Devices AGENCY: National Institute of Justice, Department of Justice...-held cell phone detector devices for participation in an evaluation by the NIJ Corrections Technology...-held cell phone detector devices for participation in an evaluation by the NIJ Corrections Technology...
A Fresh Look at the Crystal Violet Lab with Handheld Camera Colorimetry
ERIC Educational Resources Information Center
Knutson, Theodore R.; Knutson, Cassandra M.; Mozzetti, Abbie R.; Campos, Antonio R.; Haynes, Christy L.; Penn, R. Lee
2015-01-01
Chemical kinetic experiments to determine rate laws are common in high school and college chemistry courses. For reactions involving a color change, rate laws can be determined experimentally using spectrophotometric or colorimetric equipment though this equipment can be cost prohibitive. Previous work demonstrated that inexpensive handheld camera…
The State of the Art in Museum Handhelds in 2003.
ERIC Educational Resources Information Center
Proctor, Nancy; Tellis, Chris
This paper examines the rapidly changing state of museum handhelds from both a technology and content perspective. The paper also discusses the component parts for a successful museum installation: content, user interface, applications, form factor, positioning and the challenges to integrating these components. Specific examples are demonstrated…
ERIC Educational Resources Information Center
Power, Tom; Thomas, Rhodri
2007-01-01
Research exploring the ways in which information communication technologies (ICTs) could improve access to, and the quality of, teacher education in the global south (Leach et al., 2006) showed that when teachers were given sustained training, support and access to laptop and handheld computers, they found the handheld and laptop computers equally…
Efficacy of Handheld Electronic Visual Supports to Enhance Vocabulary in Children with ASD
ERIC Educational Resources Information Center
Ganz, Jennifer B.; Boles, Margot B.; Goodwyn, Fara D.; Flores, Margaret M.
2014-01-01
Although electronic tools such as handheld computers have become increasingly common throughout society, implementation of such tools to improve skills in individuals with intellectual and developmental disabilities has lagged in the professional literature. However, the use of visual scripts for individuals with disabilities, particularly those…
Payload Specialist Charles Walker with handheld protein growth experiment
1985-11-26
61B-02-014 (26 Nov-3 Dec 1985) --- Payload Specialist Charles D. Walker works with the handheld protein growth experiment -- one of a series of tests being flown to study the possibility of crystallizing biological materials. Walker rests the experiment against the larger continuous flow electrophoresis systems experiment.
Lauerman, Lloyd H
2004-12-01
Since the discovery of the polymerase chain reaction (PCR) 20 years ago, an avalanche of scientific publications have reported major developments and changes in specialized equipment, reagents, sample preparation, computer programs and techniques, generated through business, government and university research. The requirement for genetic sequences for primer selection and validation has been greatly facilitated by the development of new sequencing techniques, machines and computer programs. Genetic libraries, such as GenBank, EMBL and DDBJ continue to accumulate a wealth of genetic sequence information for the development and validation of molecular-based diagnostic procedures concerning human and veterinary disease agents. The mechanization of various aspects of the PCR assay, such as robotics, microfluidics and nanotechnology, has made it possible for the rapid advancement of new procedures. Real-time PCR, DNA microarray and DNA chips utilize these newer techniques in conjunction with computer and computer programs. Instruments for hand-held PCR assays are being developed. The PCR and reverse transcription-PCR (RT-PCR) assays have greatly accelerated the speed and accuracy of diagnoses of human and animal disease, especially of the infectious agents that are difficult to isolate or demonstrate. The PCR has made it possible to genetically characterize a microbial isolate inexpensively and rapidly for identification, typing and epidemiological comparison.
2013-01-01
Background Oral intake of a specific extract of Opuntia ficus-indica cladode and fruit skin (OpunDia™) (OFI) has been shown to increase serum insulin concentration while reducing blood glucose level for a given amount of glucose ingestion after an endurance exercise bout in healthy young volunteers. However, it is unknown whether OFI-induced insulin stimulation after exercise is of the same magnitude than the stimulation by other insulinogenic agents like leucine as well as whether OFI can interact with those agents. Therefore, the aims of the present study were: 1) to compare the degree of insulin stimulation by OFI with the effect of leucine administration; 2) to determine whether OFI and leucine have an additive action on insulin stimulation post-exercise. Methods Eleven subjects participated in a randomized double-blind cross-over study involving four experimental sessions. In each session the subjects successively underwent a 2-h oral glucose tolerance test (OGTT) after a 30-min cycling bout at ~70% VO2max. At t0 and t60 during the OGTT, subjects ingested 75 g glucose and capsules containing either 1) a placebo; 2) 1000 mg OFI; 3) 3 g leucine; 4) 1000 mg OFI + 3 g leucine. Blood samples were collected before and at 30-min intervals during the OGTT for determination of blood glucose and serum insulin. Results Whereas no effect of leucine was measured, OFI reduced blood glucose at t90 by ~7% and the area under the glucose curve by ~15% and increased serum insulin concentration at t90 by ~35% compared to placebo (P<0.05). From t60 to the end of the OGTT, serum insulin concentration was higher in OFI+leucine than in placebo which resulted in a higher area under the insulin curve (+40%, P<0.05). Conclusion Carbohydrate-induced insulin stimulation post-exercise can be further increased by the combination of OFI with leucine. OFI and leucine could be interesting ingredients to include together in recovery drinks to resynthesize muscle glycogen faster post-exercise. Still, it needs to be confirmed that such nutritional strategy effectively stimulates post-exercise muscle glycogen resynthesis. PMID:24144232
Ascensão, António; Ferreira, Rita; Magalhães, José
2007-04-12
Myocardial injury is a major contributor to the morbidity and mortality associated with coronary artery disease. Regular exercise has been confirmed as a pragmatic countermeasure to protect against cardiac injury. Specifically, endurance exercise has been proven to provide cardioprotection against cardiac insults in both young and old animals. Proposed mechanisms to explain the cardioprotective effects of exercise are mediated, at least partially, by redox changes and include the induction of myocardial heat shock proteins, improved cardiac antioxidant capacity, and/or elevation of other cardioprotective molecules. Understanding the molecular basis for exercise-induced cardioprotection is important in developing exercise strategies to protect the heart during and after insults. Data suggest that these positive modulator effects occur at different levels of cellular organization, being mitochondria fundamental organelles that are sensitive to disturbances imposed by exercise on basal homeostasis. At present, which of these protective mechanisms is essential for exercise-induced cardioprotection remains unclear. This review analyzes the biochemical, morphological and functional outcomes of acute and chronic exercise on the overall cardiac muscle tissue and in isolated mitochondria. Some redox-based mechanisms behind the cross-tolerance effects particularly induced by endurance training, against certain stressors responsible for the impairments in cardiac homeostasis caused by aging, diabetes, drug administration or ischemia-reperfusion are also outlined. Further work should be addressed in order to clarify the precise regulatory mechanisms by which physical exercise augments heart tolerance against many cardiotoxic agents.
Application of Handheld Laser-Induced Breakdown Spectroscopy (LIBS) to Geochemical Analysis.
Connors, Brendan; Somers, Andrew; Day, David
2016-05-01
While laser-induced breakdown spectroscopy (LIBS) has been in use for decades, only within the last two years has technology progressed to the point of enabling true handheld, self-contained instruments. Several instruments are now commercially available with a range of capabilities and features. In this paper, the SciAps Z-500 handheld LIBS instrument functionality and sub-systems are reviewed. Several assayed geochemical sample sets, including igneous rocks and soils, are investigated. Calibration data are presented for multiple elements of interest along with examples of elemental mapping in heterogeneous samples. Sample preparation and the data collection method from multiple locations and data analysis are discussed. © The Author(s) 2016.
Handheld computers in nursing education: PDA pilot project.
Koeniger-Donohue, Rebecca
2008-02-01
Interest in the use and application of handheld technology at undergraduate and graduate nursing programs across the country is growing rapidly. Personal digital assistants (PDAs) are often referred to as a "peripheral brain" because they can save time, decrease errors, and simplify information retrieval at the point of care. In addition, research results support the notion that PDAs enhance nursing clinical education and are an effective student learning resource. However, most nursing programs lack the full range of technological resources to implement and provide ongoing support for handheld technology use by faculty and students. This article describes a 9-month pilot project for the initial use of PDAs by novice faculty and students at Simmons College.
78 FR 20695 - Walk-Through Metal Detectors and Hand-Held Metal Detectors Test Method Validation
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-05
... Detectors and Hand-Held Metal Detectors Test Method Validation AGENCY: National Institute of Justice, DOJ... ensure that the test methods in the standards are properly documented, NIJ is requesting proposals (including price quotes) for test method validation efforts from testing laboratories. NIJ is also seeking...
How to use hand-held computers to evaluate wood drying.
Howard N. Rosen; Darrell S. Martin
1985-01-01
Techniques have been developed to evaluate end generate wood drying curves with hand-held computers (3-5K memory). Predictions of time to dry to a specific moisture content, drying rates, and other characteristics of wood drying curves can be made. The paper describes the development of programs and illustrates their use.
Notebooks, Handhelds, and Software in Physical Education (Grades 5-8)
ERIC Educational Resources Information Center
Mohnsen, Bonnie
2005-01-01
Heart monitors, pedometers, and now virtual reality-based equipment (e.g., Cyberbikes, "Dance Dance Revolution") have been embraced by physical educators as technologies worth using in the physical education program; however, the use of computers (be it a desktop, notebook, or handheld) in the physical education instructional program, has not been…
Probeware: Illuminating the Invisible
ERIC Educational Resources Information Center
Brunsell, Eric; Horejsi, Martin
2010-01-01
Probeware is the combination of sensors and software connected to a computer or handheld device. At the heart of probeware is a digital sensor that measures a particular physical parameter. One or more sensors are plugged into an interface, a calculator, and a handheld device. With the click of a button, probeware collects and graphs data in real…
Epilepsy Forewarning Using A Hand-Held Device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hively, LM
2005-02-21
Over the last decade, ORNL has developed and patented a novel approach for forewarning of a large variety of machine and biomedical events. The present implementation uses desktop computers to analyze archival data. This report describes the next logical step in this effort, namely use of a hand-held device for the analysis.
A Conceptual Framework Based on Activity Theory for Mobile CSCL
ERIC Educational Resources Information Center
Zurita, Gustavo; Nussbaum, Miguel
2007-01-01
There is a need for collaborative group activities that promote student social interaction in the classroom. Handheld computers interconnected by a wireless network allow people who work on a common task to interact face to face while maintaining the mediation afforded by a technology-based system. Wirelessly interconnected handhelds open up new…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-27
... makes clear what type of information may be communicated to and from hand-held devices. \\8\\ 15 U.S.C...\\ NYSE approved portable telephones,\\6\\ or through a written electronic communication from the Floor brokers' hand-held device as permitted by the NYSE's ``Wireless Data Communications Initiatives...
NEDLite user's manual: forest inventory for Palm OS handheld computers
Peter D. Knopp; Mark J. Twery
2006-01-01
A user's manual for NEDLite, software that enables collection of forest inventory data on Palm OS handheld computers, with the option of transferring data into NED software for analysis and subsequent prescription development. NEDLite software is included. Download the NEDLite software at: http://www.fs.fed.us/ne/burlington/ned
ERIC Educational Resources Information Center
Klopfer, Eric; Squire, Kurt
2008-01-01
The form factors of handheld computers make them increasingly popular among K-12 educators. Although some compelling examples of educational software for handhelds exist, we believe that the potential of this platform are just being discovered. This paper reviews innovative applications for mobile computing for both education and entertainment…
Technology in the College Classroom.
ERIC Educational Resources Information Center
Earl, Archie W., Sr.
An analysis was made of the use of computing tools at the graduate and undergraduate levels in colleges and universities in the United States. Topics ranged from hand-held calculators to the use of main-frame computers and the assessment of the SPSSX, SPSS, LINDO, and MINITAB computer software packages. Hand-held calculators are being increasingly…
Analysis of Peer Interaction in Learning Activities with Personal Handhelds and Shared Displays
ERIC Educational Resources Information Center
Liu, Chen-Chung; Chung, Chen-Wei; Chen, Nian-Shing; Liu, Baw-Jhiune
2009-01-01
Collaborative learning is extensively applied in classroom activities, but the screens on handheld devices are designed for individual-user mobile applications and may constrain interaction among group learners. The small screen size may lead to fragmented and tete-a-tete communication patterns and frequently obstruct the externalization of the…
2008-04-01
5 Fluxgate magnetometer ... magnetometer into digital format, and transmitted as a single serial data string to log the Cs and fluxgate magnetometer data. After procurement...Hardware The system hardware comprises an EMI sensor, Cs vapor magnetometer , fluxgate magnetometer , hand-held data acquisition computer, integrated
Hand-held Calculators: Past, Present, and Future
ERIC Educational Resources Information Center
Bell, Max; And Others
1977-01-01
Recommendations of several publications with regard to the use of hand-held calculators in the mathematics curriculum are presented. Relevant portions of the NACOME and Euclid Conference reports are cited as well as a report to NSF and recommendations from an NIE/NSF conference. Recommendations support expanded use of, and research concerning,…
Online Responses towards Parental Rearing Styles Regarding Hand-Held Devices
ERIC Educational Resources Information Center
Geng, Gretchen; Disney, Leigh
2014-01-01
This article reviewed the literature on parental rearing styles and used responses from an online discussion forum to investigate people's opinions towards parental rearing styles and strategies when children use hand-held devices. Critical discourse analysis (CDA) was used as an analysis method via micro, meso and macro multi-level…
Monitoring invasive plants using hand-held GIS technology
Theresa M. Mau-Crimmins; Barron J. Orr
2005-01-01
Successful control of invasive species requires a clear picture of the spatial extent of infestations. The latest mapping technology involves coupling global position systems and handheld computers running geographic information systems software in the field. A series of workshops applying this technology to mapping weeds was developed and presented to Weed Management...
Handheld, Wireless Computers: Can They Improve Learning and Instruction?
ERIC Educational Resources Information Center
Moallem, Mahnaz; Kermani, Hengameh; Chen, Sue-Jen
2006-01-01
Reports show that handheld, wireless computers, once used by business professionals to keep track of appointments, contacts, e-mail, and the Internet, have found their way into classrooms and schools across the United States. However, there has not been much systematic research to investigate the effects of these new technology tools on student…
Introducing Pocket PCs in Schools: Attitudes and Beliefs in the First Year
ERIC Educational Resources Information Center
Ng, Wan; Nicholas, Howard
2009-01-01
As more schools adopt the use of handheld computers in their classrooms, research that systematically tracks their introduction is essential in order to develop a model for successful implementation leading to improved classroom teaching. This research report seeks to explore the realities of introducing and integrating handheld computers into…
A Study of the Use of a Handheld Computer Algebra System in Discrete Mathematics
ERIC Educational Resources Information Center
Powers, Robert A.; Allison, Dean E.; Grassl, Richard M.
2005-01-01
This study investigated the impact of the TI-92 handheld Computer Algebra System (CAS) on student achievement in a discrete mathematics course. Specifically, the researchers examined the differences between a CAS section and a control section of discrete mathematics on students' in-class examinations. Additionally, they analysed student approaches…
49 CFR 177.804 - Compliance with Federal Motor Carrier Safety Regulations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... require texting while driving. (c) Prohibition against the use of hand-held mobile telephones. In... those regulations apply. (b) Prohibition against texting. In accordance with § 392.80 of the FMCSRs a... 42 CFR part 73 may not engage in, allow, or require use of a hand-held mobile telephone while driving...
Insect-vacs for sampling Asian citrus psyllid (Homoptera: psyllidae) on citrus trees
USDA-ARS?s Scientific Manuscript database
Three vacuum devices were compared for sampling psyllid populations. One was an AC rechargeable, handheld, cordless model and a second was a handheld, DC model powered through a cord connected to a 12V vehicle battery. Each of these devices had a mesh cylinder (substituted for a dust bag) in which...
Trends in Handheld Computing Among Medical Students
Grasso, Michael A.; Yen, M. Jim; Mintz, Matthew L.
2005-01-01
The purpose of this study was to identify trends in the utilization and acceptance of handheld computers (personal digital assistants) among medical students during preclinical and clinical training. These results can be used to identify differences between preclinical and clinical users, differences between current use and idealized use, and perceived limitations of these devices. PMID:16779255
Distributing Data from Desktop to Hand-Held Computers
NASA Technical Reports Server (NTRS)
Elmore, Jason L.
2005-01-01
A system of server and client software formats and redistributes data from commercially available desktop to commercially available hand-held computers via both wired and wireless networks. This software is an inexpensive means of enabling engineers and technicians to gain access to current sensor data while working in locations in which such data would otherwise be inaccessible. The sensor data are first gathered by a data-acquisition server computer, then transmitted via a wired network to a data-distribution computer that executes the server portion of the present software. Data in all sensor channels -- both raw sensor outputs in millivolt units and results of conversion to engineering units -- are made available for distribution. Selected subsets of the data are transmitted to each hand-held computer via the wired and then a wireless network. The selection of the subsets and the choice of the sequences and formats for displaying the data is made by means of a user interface generated by the client portion of the software. The data displayed on the screens of hand-held units can be updated at rates from 1 to
NASA Technical Reports Server (NTRS)
Aase, J. K.; Millard, J. P.; Siddoway, F. H. (Principal Investigator)
1982-01-01
Radiance measurements from handheld (Exotech 100-A) and air-borne (Daedalus DEI 1260) radiometers were related to wheat (Triticum aestivum L.) stand densities (simulated winter wheat winterkill) and to grain yield for a field located 11 km northwest of Sidney, Montana, on a Williams loam soil (fine-loamy, mixed Typic Argiborolls) where a semidwarf hard red spring wheat cultivar was needed to stand. Radiances were measured with the handheld radiometer on clear mornings throughout the growing season. Aircraft overflight measurements were made at the end of tillering and during the early stem extension period, and the mid-heading period. The IR/red ratio and normalized difference vegetation index were used in the analysis. The aircraft measurements corroborated the ground measurements inasmuch as wheat stand densities were detected and could be evaluated at an early enough growth stage to make management decision. The aircraft measurements also corroborated handheld measurements when related to yield prediction. The IR/red ratio, although there was some growth stage dependency, related well to yield when measured from just past tillering until about the watery-ripe stage.
Aboyans, V; Lacroix, P; Jeannicot, A; Guilloux, J; Bertin, F; Laskar, M
2004-09-01
We assessed the usefulness of fast-track neck sonography with a new-generation hand-held ultrasound scanner in the detection of > or =60% carotid stenosis. Patients with a past history of atherosclerotic disease or presence of risk factors were enrolled. All had fast-track carotid screening with a hand-held ultrasound scanner. Initial assessment was performed with our quick imaging protocol. A second examiner performed a conventional complete carotid duplex as gold-standard. We enrolled 197 consecutive patients with a mean age of 67 years (range 35-94). A carotid stenosis >60% was detected in 13 cases (6%). The sensitivity, specificity, positive and negative predictive value of fast-track sonography was 100%, 64%, 17% and 100%, respectively. Concomitant power Doppler imaging during the fast-track method did not improve accuracy. The use of a fast-track method with a hand-held ultrasound device can reduce the number of unnecessary carotid Duplex and enhance the screening efficiency without missing significant carotid stenoses.
Prevalence of behavior changing strategies in fitness video games: theory-based content analysis.
Lyons, Elizabeth Jane; Hatkevich, Claire
2013-05-07
Fitness video games are popular, but little is known about their content. Because many contain interactive tools that mimic behavioral strategies from weight loss intervention programs, it is possible that differences in content could affect player physical activity and/or weight outcomes. There is a need for a better understanding of what behavioral strategies are currently available in fitness games and how they are implemented. The purpose of this study was to investigate the prevalence of evidence-based behavioral strategies across fitness video games available for home use. Games available for consoles that used camera-based controllers were also contrasted with games available for a console that used handheld motion controllers. Fitness games (N=18) available for three home consoles were systematically identified and play-tested by 2 trained coders for at least 3 hours each. In cases of multiple games from one series, only the most recently released game was included. The Sony PlayStation 3 and Microsoft Xbox360 were the two camera-based consoles, and the Nintendo Wii was the handheld motion controller console. A coding list based on a taxonomy of behavioral strategies was used to begin coding. Codes were refined in an iterative process based on data found during play-testing. The most prevalent behavioral strategies were modeling (17/18), specific performance feedback (17/18), reinforcement (16/18), caloric expenditure feedback (15/18), and guided practice (15/18). All games included some kind of feedback on performance accuracy, exercise frequency, and/or fitness progress. Action planning (scheduling future workouts) was the least prevalent of the included strategies (4/18). Twelve games included some kind of social integration, with nine of them providing options for real-time multiplayer sessions. Only two games did not feature any kind of reward. Games for the camera-based consoles (mean 12.89, SD 2.71) included a greater number of strategies than those for the handheld motion controller console (mean 10.00, SD 2.74, P=.04). Behavioral strategies for increasing self-efficacy and self-regulation are common in home console fitness video games. Social support and reinforcement occurred in approximately half of the studied games. Strategy prevalence varies by console type, partially due to greater feedback afforded by camera-based controllers. Experimental studies are required to test the effects of these strategies when delivered as interactive tools, as this medium may represent an innovative platform for disseminating evidence-based behavioral weight loss intervention components.
Prevalence of Behavior Changing Strategies in Fitness Video Games: Theory-Based Content Analysis
Hatkevich, Claire
2013-01-01
Background Fitness video games are popular, but little is known about their content. Because many contain interactive tools that mimic behavioral strategies from weight loss intervention programs, it is possible that differences in content could affect player physical activity and/or weight outcomes. There is a need for a better understanding of what behavioral strategies are currently available in fitness games and how they are implemented. Objective The purpose of this study was to investigate the prevalence of evidence-based behavioral strategies across fitness video games available for home use. Games available for consoles that used camera-based controllers were also contrasted with games available for a console that used handheld motion controllers. Methods Fitness games (N=18) available for three home consoles were systematically identified and play-tested by 2 trained coders for at least 3 hours each. In cases of multiple games from one series, only the most recently released game was included. The Sony PlayStation 3 and Microsoft Xbox360 were the two camera-based consoles, and the Nintendo Wii was the handheld motion controller console. A coding list based on a taxonomy of behavioral strategies was used to begin coding. Codes were refined in an iterative process based on data found during play-testing. Results The most prevalent behavioral strategies were modeling (17/18), specific performance feedback (17/18), reinforcement (16/18), caloric expenditure feedback (15/18), and guided practice (15/18). All games included some kind of feedback on performance accuracy, exercise frequency, and/or fitness progress. Action planning (scheduling future workouts) was the least prevalent of the included strategies (4/18). Twelve games included some kind of social integration, with nine of them providing options for real-time multiplayer sessions. Only two games did not feature any kind of reward. Games for the camera-based consoles (mean 12.89, SD 2.71) included a greater number of strategies than those for the handheld motion controller console (mean 10.00, SD 2.74, P=.04). Conclusions Behavioral strategies for increasing self-efficacy and self-regulation are common in home console fitness video games. Social support and reinforcement occurred in approximately half of the studied games. Strategy prevalence varies by console type, partially due to greater feedback afforded by camera-based controllers. Experimental studies are required to test the effects of these strategies when delivered as interactive tools, as this medium may represent an innovative platform for disseminating evidence-based behavioral weight loss intervention components. PMID:23651701
Management of Allergic Rhinitis
Sausen, Verra O.; Marks, Katherine E.; Sausen, Kenneth P.; Self, Timothy H.
2005-01-01
Allergic rhinitis is the most common chronic childhood disease. Reduced quality of life is frequently caused by this IgE-mediated disease, including sleep disturbance with subsequent decreased school performance. Asthma and exercise-induced bronchospasm are commonly seen concurrently with allergic rhinitis, and poorly controlled allergic rhinitis negatively affects asthma outcomes. Nonsedating antihistamines or intranasal azelastine are effective agents to manage allergic rhinitis, often in combination with oral decongestants. For moderate to severe persistent disease, intranasal corticosteroids are the most effiective agents. Some patients require concomitant intranasal corticosteroids and nonsedating antihistamines for optimal management. Other available agents include leukotriene receptor antagonists, intranasal cromolyn, intranasal ipratropium, specific immunotherapy, and anti-IgE therapy. PMID:23118635
Shokri, Saeed; Aitken, Robert John; Abdolvahhabi, Mirabbas; Abolhasani, Farid; Ghasemi, Fahimeh Mohammad; Kashani, Iraj; Ejtemaeimehr, Shahram; Ahmadian, Shahin; Minaei, Bagher; Naraghi, Mohammad Ali; Barbarestani, Mohammad
2010-04-01
Anabolic-androgenic steroids are used at high doses by athletes for improving athletic ability, physical appearance and muscle mass. Unfortunately, the abuse of these agents has significantly increased. It has been established that exercise and high doses of anabolic-androgenic steroids may influence the hypothalamic-pituitary-gonadal axis, which can in turn affect testicular apoptosis. However, the effect of the combination of exercise and high dose of anabolic-androgenic steroids on testicular apoptosis is not known. We investigated the combined effects of exercise and high doses of nandrolone decanoate on apoptosis in the spermatogenic cell lineage. Five groups of male Wistar strain albino rats were treated as follows for 8 weeks: solvent of nandrolone decanoate (peanut oil) as a vehicle (Sham); nandrolone decanoate (10 mg/kg/weekly) (nandrolone decanoate); exercise (1 hr/day, 5 days a week) (exercise); nandrolone decanoate (10 mg/kg/weekly) and exercise (1 hr/day, 5 days a week) (nandrolone decanoate exercise); and sedentary control without any injection or exercise (Control). Apoptosis in the male germ line was characterized by TUNEL, caspase-3 assay and transmission electron microscopy. The weights of the testis and accessory sex organs, as well as sperm parameters significantly decreased in the experimental groups relative to the sham and control groups (p < or = 0.05). Germ cell apoptosis and a significant decrease in the number of germ cell layers in nandrolone decanoate exercise-treated testes were observed (p < or = 0.05). Exercise training seems to increase the extent of apoptotic changes caused by supraphysiological dose of nandrolone decanoate in rats, which in turn affects fertility.
Benefits of exercise therapy in peripheral arterial disease.
Osinbowale, Olusegun O; Milani, Richard V
2011-01-01
Peripheral arterial disease (PAD) is a common disorder caused largely by atherosclerosis. Although it is associated with increased morbidity and cardiovascular mortality, PAD remains underdiagnosed. Traditional PAD care has involved cardiovascular risk factor modification, use of antiplatelet agents, and revascularization. For those individuals who are eligible and willing to perform exercise therapy (ET), a significant benefit may be recognized. Despite this, ET faces several challenges to implementation. Notably, the lack of reimbursement by third party payers remains the major challenge to routine use of ET. Copyright © 2011 Elsevier Inc. All rights reserved.
Handheld spectrometers: the state of the art
NASA Astrophysics Data System (ADS)
Crocombe, Richard A.
2013-05-01
"Small" spectrometers fall into three broad classes: small versions of laboratory instruments, providing data, subsequently processed on a PC; dedicated analyzers, providing actionable information to an individual operator; and process analyzers, providing quantitative or semi-quantitative information to a process controller. The emphasis of this paper is on handheld dedicated analyzers. Many spectrometers have historically been large, possible fragile, expensive and complicated to use. The challenge over the last dozen years, as instruments have moved into the field, has been to make spectrometers smaller, affordable, rugged, easy-to-use, but most of all capable of delivering actionable results. Actionable results can dramatically improve the efficiency of a testing process and transform the way business is done. There are several keys to this handheld spectrometer revolution. Consumer electronics has given us powerful mobile platforms, compact batteries, clearly visible displays, new user interfaces, etc., while telecomm has revolutionized miniature optics, sources and detectors. While these technologies enable miniature spectrometers themselves, actionable information has demanded the development of rugged algorithms for material confirmation, unknown identification, mixture analysis and detection of suspicious materials in unknown matrices. These algorithms are far more sophisticated than the `correlation' or `dot-product' methods commonly used in benchtop instruments. Finally, continuing consumer electronics advances now enable many more technologies to be incorporated into handheld spectrometers, including Bluetooth, wireless, WiFi, GPS, cameras and bar code readers, and the continued size shrinkage of spectrometer `engines' leads to the prospect of dual technology or `hyphenated' handheld instruments.
Wireless live streaming video of laparoscopic surgery: a bandwidth analysis for handheld computers.
Gandsas, Alex; McIntire, Katherine; George, Ivan M; Witzke, Wayne; Hoskins, James D; Park, Adrian
2002-01-01
Over the last six years, streaming media has emerged as a powerful tool for delivering multimedia content over networks. Concurrently, wireless technology has evolved, freeing users from desktop boundaries and wired infrastructures. At the University of Kentucky Medical Center, we have integrated these technologies to develop a system that can wirelessly transmit live surgery from the operating room to a handheld computer. This study establishes the feasibility of using our system to view surgeries and describes the effect of bandwidth on image quality. A live laparoscopic ventral hernia repair was transmitted to a single handheld computer using five encoding speeds at a constant frame rate, and the quality of the resulting streaming images was evaluated. No video images were rendered when video data were encoded at 28.8 kilobytes per second (Kbps), the slowest encoding bitrate studied. The highest quality images were rendered at encoding speeds greater than or equal to 150 Kbps. Of note, a 15 second transmission delay was experienced using all four encoding schemes that rendered video images. We believe that the wireless transmission of streaming video to handheld computers has tremendous potential to enhance surgical education. For medical students and residents, the ability to view live surgeries, lectures, courses and seminars on handheld computers means a larger number of learning opportunities. In addition, we envision that wireless enabled devices may be used to telemonitor surgical procedures. However, bandwidth availability and streaming delay are major issues that must be addressed before wireless telementoring becomes a reality.
Epidemiology of Handheld Cell Phone Use While Driving: A Study from a South Indian City
Majgi, Sumanth Mallikarjuna; AiswaryaLakshmi, A. S.
2018-01-01
Background: Using cell phones while driving contribute to distractions which can potentially cause minor or major road traffic injuries and also stress among other drivers. With this background, the study was done to ascertain the proportion of handheld cell phone use while driving among road users in Mysore city and also patterns of the use by the day of week, type of road, and type of vehicle. Methods: The study was conducted in Mysore, Karnataka, India. Four stretches of roads were observed thrice daily for 1 week. The total number of vehicles passing through the stretch and the number and characteristics of drivers using hand-held cell was noted. Pearson's Chi-square test was used to ascertain the significance of the difference in proportions. Results: The overall proportion of cell phone users was calculated as 1.41/100 vehicles. The observed use of handheld cell phones was 1.78 times higher on nonbusy roads than busy roads (Χ2 = 25.79, P < 0.0001). More than 50% of the handheld phone users were driving a two wheeler, the proportion being 50.5% in busy roads, and 67% in nonbusy roads. There was no difference in the proportion of cell phone use by time of the day or across different days of the week. Conclusions: The proportion of drivers who use cell phones is found to be relatively lower, and use of cell phones was higher on nonbusy roads. PMID:29619153
Epidemiology of Handheld Cell Phone Use While Driving: A Study from a South Indian City.
Majgi, Sumanth Mallikarjuna; AiswaryaLakshmi, A S
2018-01-01
Using cell phones while driving contribute to distractions which can potentially cause minor or major road traffic injuries and also stress among other drivers. With this background, the study was done to ascertain the proportion of handheld cell phone use while driving among road users in Mysore city and also patterns of the use by the day of week, type of road, and type of vehicle. The study was conducted in Mysore, Karnataka, India. Four stretches of roads were observed thrice daily for 1 week. The total number of vehicles passing through the stretch and the number and characteristics of drivers using hand-held cell was noted. Pearson's Chi-square test was used to ascertain the significance of the difference in proportions. The overall proportion of cell phone users was calculated as 1.41/100 vehicles. The observed use of handheld cell phones was 1.78 times higher on nonbusy roads than busy roads ( Χ 2 = 25.79, P < 0.0001). More than 50% of the handheld phone users were driving a two wheeler, the proportion being 50.5% in busy roads, and 67% in nonbusy roads. There was no difference in the proportion of cell phone use by time of the day or across different days of the week. The proportion of drivers who use cell phones is found to be relatively lower, and use of cell phones was higher on nonbusy roads.
Ito, Akihiro; Ohta, Mitsuhiko; Kato, Yukinari; Inada, Shunko; Kato, Toshio; Nakata, Susumu; Yatabe, Yasushi; Goto, Mitsuo; Kaneda, Norio; Kurita, Kenichi; Nakanishi, Hayao; Yoshida, Kenji
2018-01-01
Podoplanin is distinctively overexpressed in oral squamous cell carcinoma than oral benign neoplasms and plays a crucial role in the pathogenesis and metastasis of oral squamous cell carcinoma but its diagnostic application is quite limited. Here, we report a new near-infrared fluorescence imaging method using an indocyanine green (ICG)-labeled anti-podoplanin antibody and a desktop/a handheld ICG detection device for the visualization of oral squamous cell carcinoma-xenografted tumors in nude mice. Both near-infrared imaging methods using a desktop (in vivo imaging system: IVIS) and a handheld device (photodynamic eye: PDE) successfully detected oral squamous cell carcinoma tumors in nude mice in a podoplanin expression-dependent manner with comparable sensitivity. Of these 2 devices, only near-infrared imaging methods using a handheld device visualized oral squamous cell carcinoma xenografts in mice in real time. Furthermore, near-infrared imaging methods using the handheld device (PDE) could detect smaller podoplanin-positive oral squamous cell carcinoma tumors than a non-near-infrared, autofluorescence-based imaging method. Based on these results, a near-infrared imaging method using an ICG-labeled anti-podoplanin antibody and a handheld detection device (PDE) allows the sensitive, semiquantitative, and real-time imaging of oral squamous cell carcinoma tumors and therefore represents a useful tool for the detection and subsequent monitoring of malignant oral neoplasms in both preclinical and some clinical settings.
Ito, Akihiro; Ohta, Mitsuhiko; Kato, Yukinari; Inada, Shunko; Kato, Toshio; Nakata, Susumu; Yatabe, Yasushi; Goto, Mitsuo; Kaneda, Norio; Kurita, Kenichi; Nakanishi, Hayao; Yoshida, Kenji
2018-01-01
Podoplanin is distinctively overexpressed in oral squamous cell carcinoma than oral benign neoplasms and plays a crucial role in the pathogenesis and metastasis of oral squamous cell carcinoma but its diagnostic application is quite limited. Here, we report a new near-infrared fluorescence imaging method using an indocyanine green (ICG)–labeled anti-podoplanin antibody and a desktop/a handheld ICG detection device for the visualization of oral squamous cell carcinoma–xenografted tumors in nude mice. Both near-infrared imaging methods using a desktop (in vivo imaging system: IVIS) and a handheld device (photodynamic eye: PDE) successfully detected oral squamous cell carcinoma tumors in nude mice in a podoplanin expression–dependent manner with comparable sensitivity. Of these 2 devices, only near-infrared imaging methods using a handheld device visualized oral squamous cell carcinoma xenografts in mice in real time. Furthermore, near-infrared imaging methods using the handheld device (PDE) could detect smaller podoplanin-positive oral squamous cell carcinoma tumors than a non-near-infrared, autofluorescence-based imaging method. Based on these results, a near-infrared imaging method using an ICG-labeled anti-podoplanin antibody and a handheld detection device (PDE) allows the sensitive, semiquantitative, and real-time imaging of oral squamous cell carcinoma tumors and therefore represents a useful tool for the detection and subsequent monitoring of malignant oral neoplasms in both preclinical and some clinical settings. PMID:29649929
Prediction of essential oil content of oregano by hand-held and Fourier transform NIR spectroscopy.
Camps, Cédric; Gérard, Marianne; Quennoz, Mélanie; Brabant, Cécile; Oberson, Carine; Simonnet, Xavier
2014-05-01
In the framework of a breeding programme, the analysis of hundreds of oregano samples to determine their essential oil content (EOC) is time-consuming and expensive in terms of labour. Therefore developing a new method that is rapid, accurate and less expensive to use would be an asset to breeders. The aim of the present study was to develop a method based on near-inrared (NIR) spectroscopy to determine the EOC of oregano dried powder. Two spectroscopic approaches were compared, the first using a hand-held NIR device and the second a Fourier transform (FT) NIR spectrometer. Hand-held NIR (1000-1800 nm) measurements and partial least squares regression allowed the determination of EOC with R² and SEP values of 0.58 and 0.81 mL per 100 g dry matter (DM) respectively. Measurements with FT-NIR (1000-2500 nm) allowed the determination of EOC with R² and SEP values of 0.91 and 0.68 mL per 100 g DM respectively. RPD, RER and RPIQ values for the model implemented with FT-NIR data were satisfactory for screening application, while those obtained with hand-held NIR data were below the level required to consider the model as enough accurate for screening application. The FT-NIR approach allowed the development of an accurate model for EOC prediction. Although the hand-held NIR approach is promising, it needs additional development before it can be used in practice. © 2013 Society of Chemical Industry.
Mobile real-time data acquisition system for application in preventive medicine.
Neubert, Sebastian; Arndt, Dagmar; Thurow, Kerstin; Stoll, Regina
2010-05-01
In this article, the development of a system for online monitoring of a subject's physiological parameters and subjective workload regardless of location has been presented, which allows for studies on occupational health. In the sector of occupational health, modern acquisition systems are needed. Such systems can be used by the subject during usual daily routines without being influenced by the presence of an examiner. Moreover, the system's influence on the subject should be reduced to a minimum to receive reliable data from the examination. The acquisition system is based on a mobile handheld (or smart phone), which allows both management of the communication process and input of several dialog data (e.g., questionnaires). A sensor electronics module permits the acquisition of different physiological parameters and their online transmission to the handheld via Bluetooth. The mobile handheld and the sensor electronics module constitute a wireless personal area network. The handheld allows the first analysis, the synchronization of the data, and the continuous data transfer to a communication server by the integrated mobile radio standards of the handheld. The communication server stores the incoming data of several subjects in an application-dependent database and allows access from all over the world via a Web-based management system. The developed system permits one examiner to monitor the physiological parameters and the subjective workload of several subjects in different locations at the same time. Thereby the subjects can move almost freely in any area covered by the mobile network. The mobile handheld allows the popping-up of the questionnaires at flexible time intervals. This electronic input of the dialog data, in comparison to the manual documentation on papers, is more comfortable to the subject as well as to the examiner for an analysis. A Web-based management application facilitates a continuous remote monitoring of the physiological and the subjective data of the subject.
Owens, Nicholas A; Laurentius, Lars B; Porter, Marc D; Li, Qun; Wang, Sean; Chatterjee, Delphi
2018-01-01
Techniques for the detection of disease biomarkers are key components in the protection of human health. While work over the last few decades has redefined the low-level measurement of disease biomarkers, the translation of these capabilities from the formal clinical setting to point-of-need (PON) usage has been much more limited. This paper presents the results of experiments designed to examine the potential utility of a handheld Raman spectrometer as a PON electronic reader for a sandwich immunoassay based on surface-enhanced Raman scattering (SERS). In so doing, the study herein used a recently developed procedure for the SERS detection of phospho-myo-inositol-capped lipoarabinomannan (PILAM) as a means to compare the performance of laboratory-grade and handheld instrumentation and, therefore, gauge the utility of the handheld instrument for PON deployment. Phospho-myo-inositol-capped lipoarabinomannan is a non-pathogenic simulant for mannose-capped lipoarabinomannan (ManLAM), which is an antigenic marker found in serum and other body fluids of individuals infected with tuberculosis (TB). The results of the measurements with the field-portable spectrometer were then compared to those obtained for the same samples when using a much more sensitive benchtop Raman spectrometer. The results, albeit under different operational settings for the two spectrometers (e.g., signal integration time), are promising in that the limit of detection found for PILAM spiked in human serum when using the handheld system (0.18 ng/mL) approached that of the benchtop instrument (0.032 ng/mL). This work also: (1) identified potential adaptations (e.g., optimization of the plasmonically enhanced response for measurement by the handheld unit through a change in the excitation wavelength) to tighten the gap in performance; and (2) briefly examined the next steps and potential processes required to move this immunoassay platform closer to PON utility.
Intelligent Software Agents: Sensor Integration and Response
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kulesz, James J; Lee, Ronald W
2013-01-01
Abstract In a post Macondo world the buzzwords are Integrity Management and Incident Response Management. The twin processes are not new but the opportunity to link the two is novel. Intelligent software agents can be used with sensor networks in distributed and centralized computing systems to enhance real-time monitoring of system integrity as well as manage the follow-on incident response to changing, and potentially hazardous, environmental conditions. The software components are embedded at the sensor network nodes in surveillance systems used for monitoring unusual events. When an event occurs, the software agents establish a new concept of operation at themore » sensing node, post the event status to a blackboard for software agents at other nodes to see , and then react quickly and efficiently to monitor the scale of the event. The technology addresses a current challenge in sensor networks that prevents a rapid and efficient response when a sensor measurement indicates that an event has occurred. By using intelligent software agents - which can be stationary or mobile, interact socially, and adapt to changing situations - the technology offers features that are particularly important when systems need to adapt to active circumstances. For example, when a release is detected, the local software agent collaborates with other agents at the node to exercise the appropriate operation, such as: targeted detection, increased detection frequency, decreased detection frequency for other non-alarming sensors, and determination of environmental conditions so that adjacent nodes can be informed that an event is occurring and when it will arrive. The software agents at the nodes can also post the data in a targeted manner, so that agents at other nodes and the command center can exercise appropriate operations to recalibrate the overall sensor network and associated intelligence systems. The paper describes the concepts and provides examples of real-world implementations including the Threat Detection and Analysis System (TDAS) at the International Port of Memphis and the Biological Warning and Incident Characterization System (BWIC) Environmental Monitoring (EM) Component. Technologies developed for these 24/7 operational systems have applications for improved real-time system integrity awareness as well as provide incident response (as needed) for production and field applications.« less
INMARSAT's personal communicator system
NASA Technical Reports Server (NTRS)
Hart, Nick; Haugli, HANS-C.; Poskett, Peter; Smith, K.
1993-01-01
Inmarsat has been providing near global mobile satellite communications since 1982 and Inmarsat terminals are currently being used in more than 130 countries. The terminals have been reduced in size and cost over the years and new technology has enabled the recent introduction of briefcase sized personal telephony terminals (Inmarsat-M). This trend continues and we are likely to see Inmarsat handheld terminals by the end of the decade. These terminals are called Inmarsat-P and this paper focuses on the various elements required to support a high quality service to handheld terminals. The main system elements are: the handheld terminals; the space segment with the associated orbits; and the gateways to terrestrial networks. It is both likely and desirable that personal handheld satellite communications will be offered by more than one system provider and this competition will ensure strong emphasis on service quality and cost of ownership. The handheld terminals also have to be attractive to a large number of potential users, and this means that the terminals must be small enough to fit in a pocket. Battery lifetime is another important consideration, and this coupled with radiation safety requirements limits the maximum radiated EIRP. The terminal G/T is mainly constrained by the gain of the omnidirectional antenna and the noise figure of the RF front end (including input losses). Inmarsat has examined, with the support of industry, a number of Geosynchronous (GSO), Medium Earth Orbit (MEO) and Low Earth Orbit (LEO) satellite options for the provision of a handheld mobile satellite service. This paper describes the key satellite and orbit parameters and tradeoffs which affect the overall quality of service and the space segment costing. The paper also stresses not only the importance of using and sharing the available mobile frequency band allocations efficiently, but also the key considerations affecting the choice of feeder link bands. The design of the gateways and the terrestrial network is critical to the overall viability of the service, and this paper also examines the key technical parameters associated with the Land Earth Stations (LES), which act as gateways into the Public Switched Telephone Network (PSTN). These not only include the design tradeoffs associated with the LES, but also the different terrestrial network interface options. The paper concludes with a brief description of the satellite propagation conditions associated with the use of handheld terminals. It describes how the handheld results in a number of propagation impairments which are not common to the previous measurements associated with vehicle mounted antennas. These measurements indicate that there is a complex tradeoff between link margin and the elevation angle to the satellite which has a significant impact on the space segment requirements and costing.
INMARSAT's personal communicator system
NASA Astrophysics Data System (ADS)
Hart, Nick; Haugli, Hans-C.; Poskett, Peter; Smith, K.
Inmarsat has been providing near global mobile satellite communications since 1982 and Inmarsat terminals are currently being used in more than 130 countries. The terminals have been reduced in size and cost over the years and new technology has enabled the recent introduction of briefcase sized personal telephony terminals (Inmarsat-M). This trend continues and we are likely to see Inmarsat handheld terminals by the end of the decade. These terminals are called Inmarsat-P and this paper focuses on the various elements required to support a high quality service to handheld terminals. The main system elements are: the handheld terminals; the space segment with the associated orbits; and the gateways to terrestrial networks. It is both likely and desirable that personal handheld satellite communications will be offered by more than one system provider and this competition will ensure strong emphasis on service quality and cost of ownership. The handheld terminals also have to be attractive to a large number of potential users, and this means that the terminals must be small enough to fit in a pocket. Battery lifetime is another important consideration, and this coupled with radiation safety requirements limits the maximum radiated EIRP. The terminal G/T is mainly constrained by the gain of the omnidirectional antenna and the noise figure of the RF front end (including input losses). Inmarsat has examined, with the support of industry, a number of Geosynchronous (GSO), Medium Earth Orbit (MEO) and Low Earth Orbit (LEO) satellite options for the provision of a handheld mobile satellite service. This paper describes the key satellite and orbit parameters and tradeoffs which affect the overall quality of service and the space segment costing. The paper also stresses not only the importance of using and sharing the available mobile frequency band allocations efficiently, but also the key considerations affecting the choice of feeder link bands. The design of the gateways and the terrestrial network is critical to the overall viability of the service, and this paper also examines the key technical parameters associated with the Land Earth Stations (LES), which act as gateways into the Public Switched Telephone Network (PSTN). These not only include the design tradeoffs associated with the LES, but also the different terrestrial network interface options. The paper concludes with a brief description of the satellite propagation conditions associated with the use of handheld terminals. It describes how the handheld results in a number of propagation impairments which are not common to the previous measurements associated with vehicle mounted antennas. These measurements indicate that there is a complex tradeoff between link margin and the elevation angle to the satellite which has a significant impact on the space segment requirements and costing.
2010-09-01
agent-based modeling platform known as MANA. The simulation is exercised over a broad range of different weapon systems types with their capabilities...Navy B.A., University of Florida, 2004 Submitted in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE IN MODELING ...aerial vehicle (UAV) will have. This study uses freely available data to build a simulation utilizing an agent-based modeling platform known as MANA
Parsons, Jonathan P; Hallstrand, Teal S; Mastronarde, John G; Kaminsky, David A; Rundell, Kenneth W; Hull, James H; Storms, William W; Weiler, John M; Cheek, Fern M; Wilson, Kevin C; Anderson, Sandra D
2013-05-01
Exercise-induced bronchoconstriction (EIB) describes acute airway narrowing that occurs as a result of exercise. EIB occurs in a substantial proportion of patients with asthma, but may also occur in individuals without known asthma. To provide clinicians with practical guidance, a multidisciplinary panel of stakeholders was convened to review the pathogenesis of EIB and to develop evidence-based guidelines for the diagnosis and treatment of EIB. The evidence was appraised and recommendations were formulated using the Grading of Recommendations, Assessment, Development, and Evaluation approach. Recommendations for the treatment of EIB were developed. The quality of evidence supporting the recommendations was variable, ranging from low to high. A strong recommendation was made for using a short-acting β(2)-agonist before exercise in all patients with EIB. For patients who continue to have symptoms of EIB despite the administration of a short-acting β(2)-agonist before exercise, strong recommendations were made for a daily inhaled corticosteroid, a daily leukotriene receptor antagonist, or a mast cell stabilizing agent before exercise. The recommendations in this Guideline reflect the currently available evidence. New clinical research data will necessitate a revision and update in the future.
Effects of Hypertension and Exercise on Cardiac Proteome Remodelling
Petriz, Bernardo A.; Franco, Octavio L.
2014-01-01
Left ventricle hypertrophy is a common outcome of pressure overload stimulus closely associated with hypertension. This process is triggered by adverse molecular signalling, gene expression, and proteome alteration. Proteomic research has revealed that several molecular targets are associated with pathologic cardiac hypertrophy, including angiotensin II, endothelin-1 and isoproterenol. Several metabolic, contractile, and stress-related proteins are shown to be altered in cardiac hypertrophy derived by hypertension. On the other hand, exercise is a nonpharmacologic agent used for hypertension treatment, where cardiac hypertrophy induced by exercise training is characterized by improvement in cardiac function and resistance against ischemic insult. Despite the scarcity of proteomic research performed with exercise, healthy and pathologic heart proteomes are shown to be modulated in a completely different way. Hence, the altered proteome induced by exercise is mostly associated with cardioprotective aspects such as contractile and metabolic improvement and physiologic cardiac hypertrophy. The present review, therefore, describes relevant studies involving the molecular characteristics and alterations from hypertensive-induced and exercise-induced hypertrophy, as well as the main proteomic research performed in this field. Furthermore, proteomic research into the effect of hypertension on other target-demerged organs is examined. PMID:24877123
Moore, Charity G.; Schenkman, Margaret; Kohrt, Wendy M.; Delitto, Anthony; Hall, Deborah A.; Corcos, Daniel
2013-01-01
A burgeoning literature suggests that exercise has a therapeutic benefit in persons with Parkinson disease (PD) and in animal models of PD, especially when animals exercise at high intensity. If exercise is to be prescribed as “first-line” or “add-on” therapy in patients with PD, we must demonstrate its efficacy and dose-response effects through testing phases similar to those used in the testing of pharmacologic agents. The SPARX Trial is a multicenter, randomized, controlled, single-blinded, Phase II study that we designed to test the feasibility of using high-intensity exercise to modify symptoms of PD and to simultaneously test the nonfutility of achieving a prespecified change in patients’ motor scores on the Unified Parkinson Disease Rating Scale (UPDRS). The trial began in May 2102 and is in the process of screening, enrolling, and randomly assigning 126 patients with early-stage PD to 1 of 3 groups: usual care (wait-listed controls), moderate-intensity exercise (4 days/week at 60%–65% maximal heart rate [HRmax]), or high-intensity exercise (4 days/week at 80%–85% HRmax). At 6-month follow-up, the trial is randomly reassigning usual care participants to a moderate-intensity or high-intensity exercise group for the remaining 6 months. The goals of the Phase II trial are to determine if participants can exercise at moderate and high intensities; to determine if either exercise yields benefits consistent with meaningful clinical change (nonfutility); and to document safety and attrition. The advantage of using a non-futility approach allows us to efficiently determine if moderate- or high-intensity exercise warrants further large-scale investigation in PD. PMID:23770108
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-28
... makes clear what type of information may be communicated to and from hand-held devices. \\8\\ 15 U.S.C... using a wired telephone line,\\5\\ NYSE Amex approved portable telephones,\\6\\ or through a written electronic communication from the Floor brokers' hand-held device as permitted by the NYSE Amex's ``Wireless...
Issues Arising on the Use of Hand-Held Calculators in Schools.
ERIC Educational Resources Information Center
D'Ambrosio, Ubiratan
This paper notes three objections to the use of hand-held calculators in schools: they would (1) block reasoning, (2) make individuals machine-dependent, and (3) broaden the gap between developed and underdeveloped nations. Each is addressed, with specific examples used to refute them. The belief is strongly expressed that calculators can aid in…
ERIC Educational Resources Information Center
Main, Susan; O'Rourke, John
2011-01-01
This paper reports on a pilot study that compared the use of commercial off-the-shelf (COTS) handheld game consoles (HGCs) with traditional teaching methods to develop the automaticity of mathematical calculations and self-concept towards mathematics for year 4 students in two metropolitan schools. One class conducted daily sessions using the HGCs…
The Use of Handheld Devices for Improved Phonemic Awareness in a Traditional Kindergarten Classroom
ERIC Educational Resources Information Center
Magagna-McBee, Cristy Ann
2010-01-01
Effective teaching strategies that improve the development of phonemic awareness are important to ensure students are fluent readers by third grade. The use of handheld devices to improve phonemic awareness with kindergarten students may be such a strategy, but no research exists that evaluates the use of these devices. This study explored the…
Chosen Striking Location and the User-Tool-Environment System
ERIC Educational Resources Information Center
Wagman, Jeffrey B.; Taylor, Kona R.
2004-01-01
Controlling a hand-held tool requires that the tool user bring the tool into contact with an environmental surface in a task-appropriate manner. This, in turn, requires applying muscular forces so as to overcome how the object resists being moved about its various axes. Perceived properties of hand-held objects tend to be constrained by inertial…
Imaging Emission Spectra with Handheld and Cellphone Cameras
ERIC Educational Resources Information Center
Sitar, David
2012-01-01
As point-and-shoot digital camera technology advances it is becoming easier to image spectra in a laboratory setting on a shoestring budget and get immediate results. With this in mind, I wanted to test three cameras to see how their results would differ. Two undergraduate physics students and I used one handheld 7.1 megapixel (MP) digital Cannon…
Learning Motivation and Adaptive Video Caption Filtering for EFL Learners Using Handheld Devices
ERIC Educational Resources Information Center
Hsu, Ching-Kun
2015-01-01
The aim of this study was to provide adaptive assistance to improve the listening comprehension of eleventh grade students. This study developed a video-based language learning system for handheld devices, using three levels of caption filtering adapted to student needs. Elementary level captioning excluded 220 English sight words (see Section 1…
Implications of Hand Held Electronic Games and Microcomputers for Informal Learning.
ERIC Educational Resources Information Center
Kee, Daniel W.
The use of hand-held electronic devices and microcomputers in places of public access and in the home are discussed. First, the different activities supported by this technology are described, with emphasis on the commonality of game playing to both hand-held devices and microcomputers. The need for research to investigate the motivational…
PDAs and Handhelds: ICT at Your Side and Not in Your Face
ERIC Educational Resources Information Center
Wishart, Jocelyn; Ramsden, Andy; McFarlane, Angela
2007-01-01
In order to evaluate the potential of Personal Digital Assistants (PDAs) or handheld computers to support initial teacher training (ITT), 14 science teacher trainees at the Graduate School of Education in the University of Bristol were given PDAs with mobile phone connectivity to use throughout the academic year. The following areas were…
USDA-ARS?s Scientific Manuscript database
Efficacies of a hand-held thermal fogger (PatriotTM) and hand-held Ultra-low volume (ULV) sprayer (TwisterTM) with combinations of two different adulticides and an insect growth regulator (pyriproxyfen) were field assessed and compared for their impact on reducing dengue vector populations in Thaila...
ERIC Educational Resources Information Center
Cihak, David F.; Bowlin, Tammy
2009-01-01
The researchers examined the use of video modeling by means of a handheld computer as an alternative instructional delivery system for learning basic geometry skills. Three high school students with learning disabilities participated in this study. Through video modeling, teacher-developed video clips showing step-by-step problem solving processes…
46 CFR 34.20-20 - Discharge outlets-T/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
... least one mounted foam appliance shall be provided for each station that is required in § 34.20-15(c). (c) The number of hand-held appliances provided shall be at least equal to the number of hose outlets at the two foam stations having the most hose outlets. Hand-held appliances shall be stowed in a well...
Rule summary, rule history, CFR citations and additional resources concerning emissions standards for engines principally used in handheld lawn and garden equipment such as trimmers, leaf blowers, and chainsaws.
DOT National Transportation Integrated Search
2002-08-01
One or more Halon 1211 hand-held fire extinguishers are specified in Federal Aviation Regulation (FAR) Part 25.851 as a requirement on transport category aircraft with 31 or more seats. Halon 1211 has been linked to the destruction of the ozone layer...
USDA-ARS?s Scientific Manuscript database
Three vacuum devices were compared for sampling psyllid populations. One was an AC rechargeable, handheld, cordless model and a second was a handheld, DC model powered through a cord connected to a 12V vehicle battery. Each of these devices had a mesh cylinder (substituted for a dust bag) in which...
Designing a Self-Contained Group Area Network for Ubiquitous Learning
ERIC Educational Resources Information Center
Chen, Nian-Shing; Kinshuk; Wei, Chun-Wang; Yang, Stephen J. H.
2008-01-01
A number of studies have evidenced that handheld devices are appropriate tools to facilitate face-to-face collaborative learning effectively because of the possibility of ample social interactions. Group Area Network, or GroupNet, proposed in this paper, uses handheld devices to fill the gap between Local Area Network and Body Area Network.…
Hand-Held Calculators in the Classroom: A Review of the Research.
ERIC Educational Resources Information Center
Parkhurst, Scott
This report surveys many of the recent investigations on calculators and their use in mathematics education. The review notes that the widespread availability of hand-held calculators and their affordability has led to their consideration as a viable tool to aid in mathematics instruction. The studies reviewed suggest that many questions are still…
Hand-Held Ultrasonic Instrument for Reading Matrix Symbols
NASA Technical Reports Server (NTRS)
Schramm, Harry F.; Kula, John P.; Gurney, John W.; Lior, Ephraim D.
2008-01-01
A hand-held instrument that would include an ultrasonic camera has been proposed as an efficient means of reading matrix symbols. The proposed instrument could be operated without mechanical raster scanning. All electronic functions from excitation of ultrasonic pulses through final digital processing for decoding matrix symbols would be performed by dedicated circuitry within the single, compact instrument housing.
Computer implemented method, and apparatus for controlling a hand-held tool
NASA Technical Reports Server (NTRS)
Wagner, Kenneth William (Inventor); Taylor, James Clayton (Inventor)
1999-01-01
The invention described here in is a computer-implemented method and apparatus for controlling a hand-held tool. In particular, the control of a hand held tool is for the purpose of controlling the speed of a fastener interface mechanism and the torque applied to fasteners by the fastener interface mechanism of the hand-held tool and monitoring the operating parameters of the tool. The control is embodied in intool software embedded on a processor within the tool which also communicates with remote software. An operator can run the tool, or through the interaction of both software, operate the tool from a remote location, analyze data from a performance history recorded by the tool, and select various torque and speed parameters for each fastener.
Sabatini, Jesse J; Nagori, Amita V; Chen, Gary; Chu, Phillip; Damavarapu, Reddy; Klapötke, Thomas M
2012-01-09
The full-up prototype testing of perchlorate-free, hand-held, signal illuminants for the US Army's M126A1 red star parachute hand-held signal is described. Compared to the perchlorate-containing control, the disclosed illuminants yielded excellent stabilities toward various ignition stimuli while offering superior pyrotechnic performance. Militarily, the illuminants provided further evidence that development of smaller hand-held signal items in an environmentally conscious way is a realistic and obtainable goal. The results are also important from the perspective of civilian fireworks, as the development of brighter, longer-burning, and environmentally compatible red-light-emitting pyrotechnics is now possible. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
8 CFR 103.1 - Delegations of authority; designation of immigration officers.
Code of Federal Regulations, 2011 CFR
2011-01-01
... immigration officers. (a) Delegations of authority. Delegations of authority to perform functions and exercise... Patrol agent, aircraft pilot, airplane pilot, helicopter pilot, deportation officer, detention..., only to the extent that the attorney is performing any immigration function), applications adjudicator...
Bisphosphonates as a Countermeasure to Space Flight Induced Bone Loss
NASA Technical Reports Server (NTRS)
LeBlanc, Adrian; Matsumoto, Toshio; Jones, Jeffrey A.; Shapiro, Jay; Lang, Thomas F.; Smith, Scott M.; Shackelford, Linda C.; Sibonga, Jean; Evans, Harlan; Spector, Elisabeth;
2009-01-01
Bisphosphonates as a Countermeasure to Space Flight Induced Bone Loss (Bisphosphonates) will determine whether antiresorptive agents, in conjunction with the routine inflight exercise program, will protect ISS crewmembers from the regional decreases in bone mineral density documented on previous ISS missions.
[Guidelines for the treatment of constipation].
Park, Moo In; Shin, Jeong Eun; Myung, Seung Jae; Huh, Kyu Chan; Choi, Chang Hwan; Jung, Sung Ae; Choi, Suck Chei; Sohn, Chong Il; Choi, Myung Gyu
2011-02-01
While constipation is a common symptom in Korea, there are no existing treatment guidelines. Although constipation may occur as a result of organic cause, there is no obstructive mucosal or structural cause in the vast majority of patients with constipation. The present paper deals with only the management of functional constipation: lifestyle changes; bulking agents and stool softeners; osmotic agents; stimulant laxatives; prokinetics; biofeedback and surgical treatments. Exercise and dietary fiber are helpful in some patients with constipation. Laxatives including bulking agents, stool softeners, osmotic agents, and stimulant laxatives have been found to be more effective than placebo at relieving symptoms of constipation. New enterokinetic agents that affect peristalsis through selective interaction with 5-hydroxytryptamine-4 receptors can be effective in patients with constipation who cannot get adequate relief from current laxatives. Biofeedback can relieve symptoms in selected patients with pelvic floor dyssynergia. Surgical treatments can be helpful in some patients with refractory constipation.
New technology for early detection of health threats
NASA Astrophysics Data System (ADS)
Southern, Šárka O.; Lilienthal, Gerald W.
2008-04-01
Governmental agencies charged with protecting the health of the population and agriculture have several main strategic objectives including the detection of harmful agents, the identification of vulnerable biological targets, the prediction of health outcomes and the development of countermeasures. New technologies are urgently needed in several critical areas of bio-chemical defense: economical and minimally invasive biosensors for field use in humans and other species important for agriculture and infrastructure, universal analytical platforms for broad-based, early warnings of threats and technologies guiding the development of countermeasures. A new technology called Stress Response Profiling (SRP) was recently developed by the Gaia Medical Institute. SRP provides a universal analytical platform for monitoring health status based on measurements of physiological stress. The platform is implemented through handheld devices that can be used for noninvasive detection of early-stage health problems. This paper summarizes SRP features, advantages and potential benefits for critical areas of homeland defense.
NASA Astrophysics Data System (ADS)
Ruggeri, Marco; Hernandez, Victor; De Freitas, Carolina; Relhan, Nidhi; Silgado, Juan; Manns, Fabrice; Parel, Jean-Marie
2016-03-01
Hand-held wide-field contact color fundus photography is currently the standard method to acquire diagnostic images of children during examination under anesthesia and in the neonatal intensive care unit. The recent development of portable non-contact hand-held OCT retinal imaging systems has proved that OCT is of tremendous help to complement fundus photography in the management of pediatric patients. Currently, there is no commercial or research system that combines color wide-field digital fundus and OCT imaging in a contact-fashion. The contact of the probe with the cornea has the advantages of reducing motion experienced by the photographer during the imaging and providing fundus and OCT images with wider field of view that includes the periphery of the retina. In this study we produce proof of concept for a contact-type hand-held unit for simultaneous color fundus and OCT live view of the retina of pediatric patients. The front piece of the hand-held unit consists of a contact ophthalmoscopy lens integrating a circular light guide that was recovered from a digital fundus camera for pediatric imaging. The custom-made rear piece consists of the optics to: 1) fold the visible aerial image of the fundus generated by the ophthalmoscopy lens on a miniaturized level board digital color camera; 2) conjugate the eye pupil to the galvanometric scanning mirrors of an OCT delivery system. Wide-field color fundus and OCT images were simultaneously obtained in an eye model and sequentially obtained on the eye of a conscious 25 year-old human subject with healthy retina.
Suomalainen, A; Brüllmann, D; Jacobs, R; Horner, K; Stamatakis, H C
2015-01-01
Handheld portable X-ray devices are increasingly used for intraoral radiography. This development introduces new challenges to staff and patient safety, for which new or revised risk assessments must be made and acted upon prior to use. Major issues might be: difficulties in using rectangular collimation with beam aiming devices, more complex matching of exposure settings to the X-ray receptor used (e.g. longer exposure times), movements owing to the units' weight, protection of the operator and third persons, and the use in uncontrolled environments. These problems may result in violation of the “as low as reasonably achievable’’, that is, ALARA principle by an increase in (re)exposures compared with the other available intraoral X-ray devices. Hence, the use of handheld portable X-ray devices should be considered only after careful and documented evaluation (which might be performed based on medical physics support), when there is evidence that handheld operation has benefits over traditional modalities and when no new risks to the operators and/or third parties are caused. It is expected that the use of handheld portable X-ray devices will be very exceptional, and for justified situations only. Special attention should be drawn to beam-aiming devices, rectangular collimation, the section of the X-ray receptor, focus–skin distance, and backscatter shielding, and that the unit delivers reproducible dose over the full set of environmental conditions (e.g. battery status and temperature). PMID:25710118
Audiovisual Presentations on a Handheld PC are Preferred As an Educational Tool by NICU Parents.
Alur, P; Cirelli, J; Goodstein, M; Bell, T; Liss, J
2010-01-01
Health literacy is critical for understanding complex medical problems and necessary for the well being of the patient. Printed educational materials (PM) have limitations in explaining the dynamics of a disease process. Multimedia formats may be useful for enhancing the educational process. To evaluate whether a printed format or animation with commentary on a handheld personal computer (PC) is preferred as an educational tool by parents of a baby in the NICU. PARENTS EVALUATED TWO FORMATS: A 1-page illustrated document from the American Heart Association explaining patent ductus arteriosus (PDA) and animation with commentary on a handheld PC that explained the physiology of PDA in 1 minute. The reading grade level of the PM was 8.6 versus 18.6 for the audio portion of the animated presentation. Parents viewed each format and completed a four-item questionnaire. Parents rated both formats and indicated their preference as printed, animation, or both. Forty-six parents participated in the survey. Parents preferred animation over PM (50% vs. 17.4%. p = 0.02); 39.1% expressed that the animation was excellent; whereas 4.3% expressed that the PM was excellent (p<0.001). The order of presentation of formats, sex, age, and educational level of parents did not influence the method preferred (p>0.05). Parents preferred animation on a small screen handheld PC despite a much higher language level. Because handheld PCs are portable and inexpensive, they can be used effectively at the bedside with low-cost animation to enhance understanding of complex disease conditions.
Audiovisual Presentations on a Handheld PC are Preferred As an Educational Tool by NICU Parents
Alur, P.; Cirelli, J.; Goodstein, M.; Bell, T.; Liss, J.
2010-01-01
Background Health literacy is critical for understanding complex medical problems and necessary for the well being of the patient. Printed educational materials (PM) have limitations in explaining the dynamics of a disease process. Multimedia formats may be useful for enhancing the educational process. Objective To evaluate whether a printed format or animation with commentary on a handheld personal computer (PC) is preferred as an educational tool by parents of a baby in the NICU. Methods Parents evaluated two formats: A 1-page illustrated document from the American Heart Association explaining patent ductus arteriosus (PDA) and animation with commentary on a handheld PC that explained the physiology of PDA in 1 minute. The reading grade level of the PM was 8.6 versus 18.6 for the audio portion of the animated presentation. Parents viewed each format and completed a four-item questionnaire. Parents rated both formats and indicated their preference as printed, animation, or both. Results Forty-six parents participated in the survey. Parents preferred animation over PM (50% vs. 17.4%. p = 0.02); 39.1% expressed that the animation was excellent; whereas 4.3% expressed that the PM was excellent (p<0.001). The order of presentation of formats, sex, age, and educational level of parents did not influence the method preferred (p>0.05). Conclusion Parents preferred animation on a small screen handheld PC despite a much higher language level. Because handheld PCs are portable and inexpensive, they can be used effectively at the bedside with low-cost animation to enhance understanding of complex disease conditions. PMID:23616833
Marsh, Dan J; Fox, Andreas; Grobbelaar, Adriaan O; Chana, Jagdeep S
2015-02-01
Seroma formation remains a significant problem in abdominoplasty procedures--the cause of which remains to be elucidated. It has been suggested that one of the causative factors for seroma formation is the use of handheld electrocautery as opposed to scalpel for abdominal flap dissection. Prospective trial in 102 consecutive abdominoplasty patients randomised to have abdominal flap dissection with either handheld electrocautery device on 'coagulation setting' or sharp dissection with scalpel and monopolar electrocautery forceps for haemostasis. In all other aspects the surgical technique was identical between the two groups. All drains were removed at 48 h, irrespective of drain volume. Primary outcome measure is postoperative seroma formation on clinical examination, secondary outcome measures are drain volume, weight of tissue removed, effect of liposuction and patient BMI. Both study groups were similar in demographics with no significant difference in weight of tissue excised, BMI, drain output or post operative complictions. There was no significant difference in seroma formation rates between the handheld electrocautery group (17.2%) and the sharp dissection group (20.1%). Overall, the seroma rate was 18.6%. Liposuction to the flanks at the time of abdominoplasty was found to significantly increase the incidence of seroma, compared to patients having abdominoplasty alone. Use of handheld electrocautery rather than scalpel for tissue dissection does not lead to increased seroma formation in abdominoplasty patients. Concomitant liposuction at the time of abdominoplasty increases the risk of seroma formation compared to patients having abdominoplasty alone. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Acute pain management efficiency improves with point-of-care handheld electronic billing system.
Fahy, Brenda G
2009-02-01
Technology advances continue to impact patient care and physician workflow. To enable more efficient performance of billing activities, a point-of-care (POC) handheld computer technology replaced a paper-based system on an acute pain management service. Using a handheld personal digital assistant (PDA) and software from MDeverywhere (MDe, MDeverywhere, Long Island, NY), we performed a 1-yr prospective observational study of an anesthesiology acute pain management service billings and collections. Seventeen anesthesiologists providing billable acute pain services were trained and entered their charges on a PDA. Twelve months of data, just before electronic implementation (pre-elec), were compared to a 12-m period after implementation (post-elec). The total charges were 4883 for 890 patients pre-elec and 5368 for 1128 patients post-elec. With adoption of handheld billing, the charge lag days decreased from 29.3 to 7.0 (P < 0.001). The days in accounts receivable trended downward from 59.9 to 51.1 (P = 0.031). The average number of charge lag days decreased significantly with month (P = 0.0002). The net collection rate increased from 37.4% pre-elec to 40.3% post-elec (P < 0.001). The return on investment was 1.18 fold (118%). Implementation of POC electronic billing using PDAs to replace a paper-based billing system improved the collection rate and decreased the number of charge lag days with a positive return on investment. The handheld PDA billing system provided POC support for physicians during their daily clinical (e.g., patient locations, rounding lists) and billing activities, improving workflow.
Hand-held internet tablets for school-based data collection.
Denny, Simon J; Milfont, Taciano L; Utter, Jennifer; Robinson, Elizabeth M; Ameratunga, Shanthi N; Merry, Sally N; Fleming, Theresa M; Watson, Peter D
2008-07-26
In the last 20 years, researchers have been using computer self-administered questionnaires to gather data on a wide range of adolescent health related behaviours. More recently, researchers collecting data in schools have started to use smaller hand-held computers for their ease of use and portability. The aim of this study is to describe a new technology with wi-fi enabled hand-held internet tablets and to compare adolescent preferences of laptop computers or hand-held internet tablets in administering a youth health and well-being questionnaire in a school setting. A total of 177 students took part in a pilot study of a national youth health and wellbeing survey. Students were randomly assigned to internet tablets or laptops at the start of the survey and were changed to the alternate mode of administration about half-way through the questionnaire. Students at the end of the questionnaire were asked which of the two modes of administration (1) they preferred, (2) was easier to use, (3) was more private and confidential, and (4) was easier to answer truthfully. Many students expressed no preference between laptop computers or internet tablets. However, among the students who expressed a preference between laptop computers or internet tablets, the majority of students found the internet tablets more private and confidential (p < 0.001) and easier to answer questions truthfully (p < 0.001) compared to laptop computers. This study demonstrates that using wi-fi enabled hand-held internet tablets is a feasible methodology for school-based surveys especially when asking about sensitive information.
Hand-held internet tablets for school-based data collection
Denny, Simon J; Milfont, Taciano L; Utter, Jennifer; Robinson, Elizabeth M; Ameratunga, Shanthi N; Merry, Sally N; Fleming, Theresa M; Watson, Peter D
2008-01-01
Background In the last 20 years, researchers have been using computer self-administered questionnaires to gather data on a wide range of adolescent health related behaviours. More recently, researchers collecting data in schools have started to use smaller hand-held computers for their ease of use and portability. The aim of this study is to describe a new technology with wi-fi enabled hand-held internet tablets and to compare adolescent preferences of laptop computers or hand-held internet tablets in administering a youth health and well-being questionnaire in a school setting. Methods A total of 177 students took part in a pilot study of a national youth health and wellbeing survey. Students were randomly assigned to internet tablets or laptops at the start of the survey and were changed to the alternate mode of administration about half-way through the questionnaire. Students at the end of the questionnaire were asked which of the two modes of administration (1) they preferred, (2) was easier to use, (3) was more private and confidential, and (4) was easier to answer truthfully. Results Many students expressed no preference between laptop computers or internet tablets. However, among the students who expressed a preference between laptop computers or internet tablets, the majority of students found the internet tablets more private and confidential (p < 0.001) and easier to answer questions truthfully (p < 0.001) compared to laptop computers. Conclusion This study demonstrates that using wi-fi enabled hand-held internet tablets is a feasible methodology for school-based surveys especially when asking about sensitive information. PMID:18710505
Laher, Ismail; Beam, Julianne; Botta, Amy; Barendregt, Rebekah; Sulistyoningrum, Dian; Devlin, Angela; Rheault, Mark; Ghosh, Sanjoy
2013-01-01
Moderate exercise improves cardiac antioxidant status in young humans and animals with Type-2 diabetes (T2D). Given that both diabetes and advancing age synergistically decrease antioxidant expression in most tissues, it is unclear whether exercise can upregulate cardiac antioxidants in chronic animal models of T2D. To this end, 8-month-old T2D and normoglycemic mice were exercised for 3 weeks, and cardiac redox status was evaluated. As expected, moderate exercise increased cardiac antioxidants and attenuated oxidative damage in normoglycemic mice. In contrast, similar exercise protocol in 8-month-old db/db mice worsened cardiac oxidative damage, which was associated with a specific dysregulation of glutathione (GSH) homeostasis. Expression of enzymes for GSH biosynthesis [γ-glutamylcysteine synthase, glutathione reductase] as well as for GSH-mediated detoxification (glutathione peroxidase, glutathione-S-transferase) was lower, while toxic metabolites dependent on GSH for clearance (4-hydroxynonenal) were increased in exercised diabetic mice hearts. To validate GSH loss as an important factor for such aggravated damage, daily administration of GSH restored cardiac GSH levels in exercised diabetic mice. Such supplementation attenuated both oxidative damage and fibrotic changes in the myocardium. Expression of transforming growth factor beta (TGF-β) and its regulated genes which are responsible for such profibrotic changes were also attenuated with GSH supplementation. These novel findings in a long-term T2D animal model demonstrate that short-term exercise by itself can deplete cardiac GSH and aggravate cardiac oxidative stress. As GSH administration conferred protection in 8-month-old diabetic mice undergoing exercise, supplementation with GSH-enhancing agents may be beneficial in elderly diabetic patients undergoing exercise.
Peter, W F; Jansen, M J; Hurkmans, E J; Bloo, H; Dekker, J; Dilling, R G; Hilberdink, W; Kersten-Smit, C; de Rooij, M; Veenhof, C; Vermeulen, H M; de Vos, R J; Schoones, J W; Vliet Vlieland, T P
2011-01-01
An update of a Dutch physiotherapy practice guideline in Hip and Knee Osteoarthritis (HKOA) was made, based on current evidence and best practice. A guideline steering committee, comprising 10 expert physiotherapists, selected topics concerning the guideline chapters: initial assessment, treatment and evaluation. With respect to treatment a systematic literature search was performed using various databases, and the evidence was graded (1-4). For the initial assessment and evaluation mainly review papers and textbooks were used. Based on evidence and expert opinion, recommendations were formulated. A first draft of the guideline was reviewed by 17 experts from different professional backgrounds. A second draft was field-tested by 45 physiotherapists. In total 11 topics were selected. For the initial assessment, three recommendations were formulated, pertaining to history taking, red flags, and formulating treatment goals. Concerning treatment, 7 recommendations were formulated; (supervised) exercise therapy, education and self management interventions, a combination of exercise and manual therapy, postoperative exercise therapy and taping of the patella were recommended. Balneotherapy and hydrotherapy in HKOA, and thermotherapy, TENS, and Continuous Passive Motion in knee OA were neither recommended nor discouraged. Massage therapy, ultrasound, electrotherapy, electromagnetic field, Low Level Laser Therapy, preoperative physiotherapy and education could not be recommended. For the evaluation of treatment goals the following measurement instruments were recommended: Lequesne index, Western Ontario and McMaster Universities osteoarthritis index, Hip disability and Osteoarthritis Outcome Score and Knee injury and Osteoarthritis Outcome Score, 6-minute walktest, Timed Up and Go test, Patient Specific Complaint list, Visual Analoge Scale for pain, Intermittent and Constant OsteoArthritis Pain Questionnaire, goniometry, Medical Research Council for strength, handheld dynamometer. This update of a Dutch physiotherapy practice guideline on HKOA included 11 recommendations on the initial assessment, treatment and evaluation. The implementation of the guideline in clinical practice needs further evaluation.
Calik-Kutukcu, Ebru; Savci, Sema; Saglam, Melda; Vardar-Yagli, Naciye; Inal-Ince, Deniz; Arikan, Hulya; Aribas, Zeynep; Ozer, Ozge; Bosnak-Guclu, Meral; Coplu, Lutfi
2014-01-27
Chronic obstructive pulmonary disease (COPD) has significant systemic effects that substantially impact quality of life and survival. The purpose of this study was to assess and compare peripheral muscle strength and endurance, exercise capacity, fatigue perception and quality of life between patients with COPD and healthy subjects. Twenty COPD patients (mean FEV1 49.3 ± 19.2%) and 20 healthy subjects were included in the study. Pulmonary function testing and six-minute walk test (6MWT) were performed. Peripheral muscle strength was measured with a hand-held dynamometer, peripheral muscle endurance was evaluated with sit-ups, squats and modified push-ups tests. Fatigue perception was assessed using the Fatigue Impact Scale (FIS) and Fatigue Severity Scale (FSS). General quality of life was determined with the Nottingham Health Profile (NHP), and cough-specific quality of life was evaluated with the Leicester Cough Questionnaire (LCQ). Pulmonary functions, strength of shoulder abductor and flexor muscles, numbers of sit-ups and squats, 6MWT distance and 6MWT% were significantly lower in COPD patients than in healthy subjects (p < 0.05). FIS psychosocial sub-dimension and total scores, NHP scores for all sub-dimensions except pain sub-dimension of the COPD group were significantly higher than those of healthy subjects (p < 0.05). The LCQ physical, psychological and social sub-dimensions and total scores were significantly lower in COPD patients than in healthy subjects (p < 0.05). Pulmonary functions, peripheral muscle strength and endurance, exercise capacity and quality of life were adversely affected in patients with COPD. There are greater effect of fatigue on psychosocial functioning and general daily life activities and effect of cough on the quality of life in patients with COPD. This study supports the idea that COPD patients must be evaluated in a comprehensive manner for planning pulmonary rehabilitation programs.
2014-01-01
Background Chronic obstructive pulmonary disease (COPD) has significant systemic effects that substantially impact quality of life and survival. The purpose of this study was to assess and compare peripheral muscle strength and endurance, exercise capacity, fatigue perception and quality of life between patients with COPD and healthy subjects. Methods Twenty COPD patients (mean FEV1 49.3 ± 19.2%) and 20 healthy subjects were included in the study. Pulmonary function testing and six-minute walk test (6MWT) were performed. Peripheral muscle strength was measured with a hand-held dynamometer, peripheral muscle endurance was evaluated with sit-ups, squats and modified push-ups tests. Fatigue perception was assessed using the Fatigue Impact Scale (FIS) and Fatigue Severity Scale (FSS). General quality of life was determined with the Nottingham Health Profile (NHP), and cough-specific quality of life was evaluated with the Leicester Cough Questionnaire (LCQ). Results Pulmonary functions, strength of shoulder abductor and flexor muscles, numbers of sit-ups and squats, 6MWT distance and 6MWT% were significantly lower in COPD patients than in healthy subjects (p < 0.05). FIS psychosocial sub-dimension and total scores, NHP scores for all sub-dimensions except pain sub-dimension of the COPD group were significantly higher than those of healthy subjects (p < 0.05). The LCQ physical, psychological and social sub-dimensions and total scores were significantly lower in COPD patients than in healthy subjects (p < 0.05). Conclusions Pulmonary functions, peripheral muscle strength and endurance, exercise capacity and quality of life were adversely affected in patients with COPD. There are greater effect of fatigue on psychosocial functioning and general daily life activities and effect of cough on the quality of life in patients with COPD. This study supports the idea that COPD patients must be evaluated in a comprehensive manner for planning pulmonary rehabilitation programs. PMID:24468029
Molecular hydrogen in sports medicine: new therapeutic perspectives.
Ostojic, S M
2015-04-01
In the past 2 decades, molecular hydrogen emerged as a novel therapeutic agent, with antioxidant, anti-inflammatory and anti-apoptotic effects demonstrated in plethora of animal disease models and human studies. Beneficial effects of molecular hydrogen in clinical environment are observed especially in oxidative stress-mediated diseases, such as diabetes mellitus, brain stem infarction, rheumatoid arthritis, or neurodegenerative diseases. A number of more recent studies have reported that molecular hydrogen affects cell signal transduction and acts as an alkalizing agent, with these newly identified mechanisms of action having the potential to widen its application in clinical medicine even further. In particular, hydrogen therapy may be an effective and specific innovative treatment for exercise-induced oxidative stress and sports injury, with potential for the improvement of exercise performance. This review will summarize recent research findings regarding the clinical aspects of molecular hydrogen use, emphasizing its application in the field of sports medicine. © Georg Thieme Verlag KG Stuttgart · New York.
Respiratory health of elite athletes – preventing airway injury: a critical review
Kippelen, Pascale; Fitch, Kenneth D; Anderson, Sandra Doreen; Bougault, Valerie; Boulet, Louis-Philippe; Rundell, Kenneth William; Sue-Chu, Malcolm; McKenzie, Donald C
2012-01-01
Elite athletes, particularly those engaged in endurance sports and those exposed chronically to airborne pollutants/irritants or allergens, are at increased risk for upper and lower airway dysfunction. Airway epithelial injury may be caused by dehydration and physical stress applied to the airways during severe exercise hyperpnoea and/or by inhalation of noxious agents. This is thought to initiate an inflammatory cascade/repair process that, ultimately, could lead to airway hyperresponsiveness (AHR) and asthma in susceptible athletes. The authors review the evidence relating to prevention or reduction of the risk of AHR/asthma development. Appropriate measures should be implemented when athletes exercise strenuously in an attempt to attenuate the dehydration stress and reduce the exposure to noxious airborne agents. Environmental interventions are the most important. Non-pharmacological strategies can assist, but currently, pharmacological measures have not been demonstrated to be effective. Whether early prevention of airway injury in elite athletes can prevent or reduce progression to AHR/asthma remains to be established. PMID:22522585
Respiratory health of elite athletes - preventing airway injury: a critical review.
Kippelen, Pascale; Fitch, Kenneth D; Anderson, Sandra Doreen; Bougault, Valerie; Boulet, Louis-Philippe; Rundell, Kenneth William; Sue-Chu, Malcolm; McKenzie, Donald C
2012-06-01
Elite athletes, particularly those engaged in endurance sports and those exposed chronically to airborne pollutants/irritants or allergens, are at increased risk for upper and lower airway dysfunction. Airway epithelial injury may be caused by dehydration and physical stress applied to the airways during severe exercise hyperpnoea and/or by inhalation of noxious agents. This is thought to initiate an inflammatory cascade/repair process that, ultimately, could lead to airway hyperresponsiveness (AHR) and asthma in susceptible athletes. The authors review the evidence relating to prevention or reduction of the risk of AHR/asthma development. Appropriate measures should be implemented when athletes exercise strenuously in an attempt to attenuate the dehydration stress and reduce the exposure to noxious airborne agents. Environmental interventions are the most important. Non-pharmacological strategies can assist, but currently, pharmacological measures have not been demonstrated to be effective. Whether early prevention of airway injury in elite athletes can prevent or reduce progression to AHR/asthma remains to be established.
ERIC Educational Resources Information Center
Ludwig, Timothy D.; Goomas, David T.
2007-01-01
Field study was conducted in auto-parts after-market distribution centers where selectors used handheld computers to receive instructions and feedback about their product selection process. A wireless voice-interaction technology was then implemented in a multiple baseline fashion across three departments of a warehouse (N = 14) and was associated…
Hand-Held Model of a Sarcomere to Illustrate the Sliding Filament Mechanism in Muscle Contraction
ERIC Educational Resources Information Center
Jittivadhna, Karnyupha; Ruenwongsa, Pintip; Panijpan, Bhinyo
2009-01-01
From our teaching of the contractile unit of the striated muscle, we have found limitations in using textbook illustrations of sarcomere structure and its related dynamic molecular physiological details. A hand-held model of a striated muscle sarcomere made from common items has thus been made by us to enhance students' understanding of the…
ERIC Educational Resources Information Center
Huang, Yong-Ming; Huang, Yueh-Min
2015-01-01
Vocabulary is the foundation for students who learn a foreign language. Nevertheless, students may be bored by the painstaking process of rote learning. To this end, this study designed a handheld sensor-based vocabulary game based on a scaffolding strategy for improving students' motivation and achievement in vocabulary learning. On the one hand,…
ERIC Educational Resources Information Center
Sugimoto, Masanori
2011-01-01
This paper describes a system called GENTORO that uses a robot and a handheld projector for supporting children's storytelling activities. GENTORO differs from many existing systems in that children can make a robot play their own story in a physical space augmented by mixed-reality technologies. Pilot studies have been conducted to clarify the…
Applying Hand-Held 3D Printing Technology to the Teaching of VSEPR Theory
ERIC Educational Resources Information Center
Dean, Natalie L.; Ewan, Corrina; McIndoe, J. Scott
2016-01-01
The use of hand-held 3D printing technology provides a unique and engaging approach to learning VSEPR theory by enabling students to draw three-dimensional depictions of different molecular geometries, giving them an appreciation of the shapes of the building blocks of complex molecular structures. Students are provided with 3D printing pens and…
A Cheap, Semiquantitative Hand-Held Conductivity Tester.
ERIC Educational Resources Information Center
Zawacky, Susan K. S.
1995-01-01
Describes a design for a hand-held conductivity tester powered by a 9V battery that gives semi-quantitative results for aqueous electrolyte solutions of concentrations ranging from 0.001 M to 0.1 M. The tester uses a bar-graph LED driven by an LM3914 integrated circuit to indicate the level of conductivity. A list of parts, procedures, and results…
ERIC Educational Resources Information Center
What Works Clearinghouse, 2014
2014-01-01
This study examined how using two different ways of displaying the solar system--a true-to-scale mode vs. an orrery mode--affected students' knowledge of astronomical concepts. Solar system displays were presented in a software application on a handheld tablet computer. In the true-to-scale mode, users navigated a simulated three-dimensional solar…
Beyond the Organizer: A Manual of Educational Uses for the Handheld Computer.
ERIC Educational Resources Information Center
Leibiger, Carol A.
This manual was initially written to support the University of South Dakota's Palm Initiative. It has been substantially revised and updated to include the latest in handheld applications with educational uses, and it applies to any Personal Digital Assistant (PDA) using the Palm OS Software (3.1 or higher) and having at least 8 megabytes of…
The Weak Link HP-41C hand-held calculator program
Ross A. Phillips; Penn A. Peters; Gary D. Falk
1982-01-01
The Weak Link hand-held calculator program (HP-41C) quickly analyzes a system for logging production and costs. The production equations model conventional chain saw, skidder, loader, and tandemaxle truck operations in eastern mountain areas. Production of each function of the logging system may be determined so that the system may be balanced for minimum cost. The...
ERIC Educational Resources Information Center
Bennett, Kristin Redington; Cunningham, Ann C.
2009-01-01
Appropriate classroom assessment now tends to utilize formative measures with greater frequency, especially in the early grades and with learner groups at risk of not passing state-mandated standardized tests. Within the authentic context of an action research project, teacher candidates were given handheld computers equipped with data-collection…
Gonzalez, Jean; Roman, Manuela; Hall, Michael; Godavarty, Anuradha
2012-01-01
Hand-held near-infrared (NIR) optical imagers are developed by various researchers towards non-invasive clinical breast imaging. Unlike these existing imagers that can perform only reflectance imaging, a generation-2 (Gen-2) hand-held optical imager has been recently developed to perform both reflectance and transillumination imaging. The unique forked design of the hand-held probe head(s) allows for reflectance imaging (as in ultrasound) and transillumination or compressed imaging (as in X-ray mammography). Phantom studies were performed to demonstrate two-dimensional (2D) target detection via reflectance and transillumination imaging at various target depths (1-5 cm deep) and using simultaneous multiple point illumination approach. It was observed that 0.45 cc targets were detected up to 5 cm deep during transillumination, but limited to 2.5 cm deep during reflectance imaging. Additionally, implementing appropriate data post-processing techniques along with a polynomial fitting approach, to plot 2D surface contours of the detected signal, yields distinct target detectability and localization. The ability of the gen-2 imager to perform both reflectance and transillumination imaging allows its direct comparison to ultrasound and X-ray mammography results, respectively, in future clinical breast imaging studies.
Toward Automated Intraocular Laser Surgery Using a Handheld Micromanipulator
Yang, Sungwook; MacLachlan, Robert A.; Riviere, Cameron N.
2014-01-01
This paper presents a technique for automated intraocular laser surgery using a handheld micromanipulator known as Micron. The novel handheld manipulator enables the automated scanning of a laser probe within a cylinder of 4 mm long and 4 mm in diameter. For the automation, the surface of the retina is reconstructed using a stereomicroscope, and then preplanned targets are placed on the surface. The laser probe is precisely located on the target via visual servoing of the aiming beam, while maintaining a specific distance above the surface. In addition, the system is capable of tracking the surface of the eye in order to compensate for any eye movement introduced during the operation. We compared the performance of the automated scanning using various control thresholds, in order to find the most effective threshold in terms of accuracy and speed. Given the selected threshold, we conducted the handheld operation above a fixed target surface. The average error and execution time are reduced by 63.6% and 28.5%, respectively, compared to the unaided trials. Finally, the automated laser photocoagulation was demonstrated also in an eye phantom, including compensation for the eye movement. PMID:25893135
Handheld ultrasound array imaging device
NASA Astrophysics Data System (ADS)
Hwang, Juin-Jet; Quistgaard, Jens
1999-06-01
A handheld ultrasound imaging device, one that weighs less than five pounds, has been developed for diagnosing trauma in the combat battlefield as well as a variety of commercial mobile diagnostic applications. This handheld device consists of four component ASICs, each is designed using the state of the art microelectronics technologies. These ASICs are integrated with a convex array transducer to allow high quality imaging of soft tissues and blood flow in real time. The device is designed to be battery driven or ac powered with built-in image storage and cineloop playback capability. Design methodologies of a handheld device are fundamentally different to those of a cart-based system. As system architecture, signal and image processing algorithm as well as image control circuit and software in this device is deigned suitably for large-scale integration, the image performance of this device is designed to be adequate to the intent applications. To elongate the battery life, low power design rules and power management circuits are incorporated in the design of each component ASIC. The performance of the prototype device is currently being evaluated for various applications such as a primary image screening tool, fetal imaging in Obstetrics, foreign object detection and wound assessment for emergency care, etc.
Aramaki, Hidefumi; Katoh, Munenori; Hiiragi, Yukinobu; Kawasaki, Tsubasa; Kurihara, Tomohisa; Ohmi, Yorikatsu
2016-07-01
[Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subjects' right legs was measured under two posture positions using two devices: a handheld dynamometer with a belt and an isokinetic dynamometer. Reliability was evaluated using an intra-class correlation coefficient (ICC); relatedness and validity were evaluated using Pearson's product moment correlation coefficient. Differences in measurements of devices were assessed by two-way ANOVA. [Results] ICC (1, 1) was ≥0.9; significant positive correlations in measurements were found between the two devices under both conditions. No main effect was found between the measurement values. [Conclusion] Our findings revealed that there was relatedness, reliability, and validity of this method for isometric muscle strength measurements using a handheld dynamometer with a belt.
Haerinejad, Mohammad Javad; Ostovar, Afshin; Farzaneh, Mohamad Reza; Keshavarz, Mojtaba
2016-09-01
Several reports have implied progressive increase of performance-enhancing drug (PED) use among Iranian athletes. More importantly, most of the previous research in the Iranian population had mainly focused on the anabolic steroid abuse, and ignored other agents. The aim of this study was to investigate the prevalence and characteristics of PED use among bodybuilding athletes in Bushehr, south of Iran. Four hundred and fifty three male bodybuilding athletes were recruited from Bushehr gyms between February and May of 2015. Men were eligible to participate in the survey if they had regularly participated in the strength-training exercise (minimum of 1 year and 4 hour/week). Data were collected via a face-to-face interview. The survey consisted of three separate parts including demographic data, exercise pattern and PED use. According to this study, 234 (51.7%) of bodybuilding athletes had used PEDs. The PED users reported an average of 3.80 ± 4.52 agents' use in their programs and they had used PEDs for the average of 3.24 ± 3.99 years. The most prevalent agents which had been abused by the athletes were anabolic steroids (used by 185 athletes (79.4% of athletes). Furthermore, 110 (47%) of athletes reported stimulant agents' use during their routines. The most prevalent motivation for using PEDs was increasing muscle mass that was reported by 164 (70.1%) of PED users. In addition, sexual and dermatologic effects were the most prevalent adverse effects reported by the PED user athletes (114 (49.4%) and 103 (44.2%), respectively). This study showed the high rate of PED use among recreational and professional Iranian bodybuilding athletes that can expose them to the serious side effects of these agents.
Mobile chemical detector (AP2C+SP4E) as an aid for medical decision making in the battlefield.
Eisenkraft, Arik; Markel, Gal; Simovich, Shirley; Layish, Ido; Hoffman, Azik; Finkelstein, Arseny; Rotman, Eran; Dushnitsky, Tsvika; Krivoy, Amir
2007-09-01
The combination of the AP2C unit with the SP4E kit composes a lightweight mobile detector of chemical warfare agents (CWA), such as nerve and mustard agents, with both vapor- and liquid-sampling capabilities. This apparatus was recently introduced into our military medical units as an aid for detection of CWA on casualties. Importantly, critical information regarding the applicability in the battlefield was absent. In view of the serious consequences that might follow a proclamation of CWA recognition in battlefield, a high false-positive rate positions the utilization of this apparatus as a medical decision tool in question. We have therefore conducted a field experiment to test the false-positive rate as well as analyze possible factors leading to false-positive readings with this device. The experiment was carried out before and after a 4-day army field exercise, using a standard AP2C device, a SP4E surface sampling kit, and a specially designed medical sampling kit for casualties, intended for medical teams. Soldiers were examined at rest, after mild exercise, and after 4 days in the field. The readings with AP2C alone were compared to the combination of AP2C and SP4E and to the medical sampling kit. Various body fluids served as negative controls. Remarkably, we found a false-positive rate of 57% at rest and after mild exercise, and an even higher rate of 64% after the 4-day field exercise with the AP2C detector alone, as compared to almost no false-positive readings with the combination of AP2C and SP4E. Strikingly, the medical sampling kit has yielded numerous false-positive readings, even in normal body fluids such as blood, urine, and saliva. We therefore see no place for using the medical sampling kit due to an unaccepted high rate of false-positive readings. Finally, we have designed an algorithm that uses the entire apparatus of AP2C and SP4E as a reliable validation tool for medical triage in the setting of exposure to nerve agents in the battlefield.
An efficient solid modeling system based on a hand-held 3D laser scan device
NASA Astrophysics Data System (ADS)
Xiong, Hanwei; Xu, Jun; Xu, Chenxi; Pan, Ming
2014-12-01
The hand-held 3D laser scanner sold in the market is appealing for its port and convenient to use, but price is expensive. To develop such a system based cheap devices using the same principles as the commercial systems is impossible. In this paper, a simple hand-held 3D laser scanner is developed based on a volume reconstruction method using cheap devices. Unlike convenient laser scanner to collect point cloud of an object surface, the proposed method only scan few key profile curves on the surface. Planar section curve network can be generated from these profile curves to construct a volume model of the object. The details of design are presented, and illustrated by the example of a complex shaped object.
SkinScan©: A PORTABLE LIBRARY FOR MELANOMA DETECTION ON HANDHELD DEVICES
Wadhawan, Tarun; Situ, Ning; Lancaster, Keith; Yuan, Xiaojing; Zouridakis, George
2011-01-01
We have developed a portable library for automated detection of melanoma termed SkinScan© that can be used on smartphones and other handheld devices. Compared to desktop computers, embedded processors have limited processing speed, memory, and power, but they have the advantage of portability and low cost. In this study we explored the feasibility of running a sophisticated application for automated skin cancer detection on an Apple iPhone 4. Our results demonstrate that the proposed library with the advanced image processing and analysis algorithms has excellent performance on handheld and desktop computers. Therefore, deployment of smartphones as screening devices for skin cancer and other skin diseases can have a significant impact on health care delivery in underserved and remote areas. PMID:21892382
Development and Validation of the Adolescent Psychological Need Support in Exercise Questionnaire.
Emm-Collison, Lydia G; Standage, Martyn; Gillison, Fiona B
2016-10-01
Grounded within self-determination theory (SDT; Deci & Ryan, 2000; Ryan & Deci, in press), three studies were conducted to develop and psychometrically test a measure of adolescents' perceptions of psychological need support for exercise (viz., for autonomy, competence, and relatedness): the Adolescent Psychological Need Support in Exercise Questionnaire (APNSEQ). In Study 1, 34 items were developed in collaboration with an expert panel. Through categorical confirmatory factor analysis and item response theory, responses from 433 adolescents were used to identify the best fitting and performing items in Study 2. Here, a three-factor nine-item measure showed good fit to the data. In Study 3, responses from an independent sample of 373 adolescents provided further evidence for the nine-item solution as well as for internal consistency, criterion validity, and invariance across gender and social agent (friends, family, and physical education teacher). The APNSEQ was supported as a measure of adolescents' perceptions of psychological need support within the context of exercise.
Planning and preparing for public health threats at airports.
Martin, Greg; Boland, Mairin
2018-03-07
The ever-increasing speed and scope of human mobility by international air travel has led to a global transport network for infectious diseases with the potential to introduce pathogens into non-endemic areas, and to facilitate rapid spread of novel or mutated zoonotic agents.Robust national emergency preparedness is vital to mitigate the transmission of infectious diseases agents domestically and to prevent onward spread to other countries. Given the complex range of stakeholders who respond to an infectious disease threat being transmitted through air travel, it is important that protocols be tested and practised extensively in advance of a real emergency. Simulation exercises include the identification of possible scenarios based on the probability of hazards and the vulnerability of populations as a basis for planning, and provide a useful measure of preparedness efforts and capabilities.In October 2016, a live simulation exercise was conducted at a major airport in Ireland incorporating a public health threat for the first time, with the notification of a possible case of MERS-CoV aboard an aircraft plus an undercarriage fire. Strengths of the response to the communicable disease threat included appropriate public health risk assessment, case management, passenger information gathering, notification to relevant parties, and communication to passengers and multiple agencies.Lessons learned include:o Exercise planning should not be overly ambitious. In testing too many facets of emergency response, the public health response could be deprioritised.o The practical implementation of communication protocols in a real-time exercise of this scope proved challenging. These protocols should continue to be checked and tested by desk-top exercises to ensure that all staff concerned are familiar with them, especially in the context of staff turn-over.o The roles and responsibilities of the various agencies must be clear to avoid role confusion.o Equipment and infrastructure capacities must be considered and in place in advance of an actual incident or test, for example whether or not cell phone signals require boosting during a major event.Importantly, exercises bring together individuals representing organisations with different roles and perspectives allowing identification of capabilities and limitations, and problem solving about how to address the gaps and overlaps in a low-threat collaborative setting.
Gao, Ya; Wang, Changjiang; Pan, Tianrong; Luo, Li
2014-02-01
Visfatin is a recently discovered adipocytokine that contributes to glucose and obesity-related conditions. Until now, its responses to the insulin-sensitizing agent metformin and to exercise are largely unknown. We aim to investigate the impact of metformin treatment and/or swimming exercise on serum visfatin and visfatin levels in subcutaneous adipose tissue (SAT), peri-renal adipose tissue (PAT) and skeletal muscle (SM) of high-fat-induced obesity rats. Sprague-Dawley rats were fed a normal diet or a high-fat diet for 16 weeks to develop obesity model. The high-fat-induced obesity model rats were then randomized to metformin (MET), swimming exercise (SWI), or adjunctive therapy of metformin and swimming exercise (MAS), besides high-fat obesity control group and a normal control group, all with 10 rats per group. Zoometric and glycemic parameters, lipid profile, and serum visfatin levels were assessed at baseline and after 6 weeks of therapy. Visfatin levels in SAT, PAT and SM were determined by Western Blot. Metformin and swimming exercise improved lipid profile, and increased insulin sensitivity and body weight reduction were observed. Both metformin and swimming exercise down-regulated visfatin levels in SAT and PAT, while the adjunctive therapy conferred greater benefits, but no changes of visfatin levels were observed in SM. Our results indicate that visfatin down-regulation in SAT and PAT may be one of the mechanisms by which metformin and swimming exercise inhibit obesity.
NASA Astrophysics Data System (ADS)
Ishihara, Miya; Tsujita, Kazuhiro; Horiguchi, Akio; Irisawa, Kaku; Komatsu, Tomohiro; Ayaori, Makoto; Hirasawa, Takeshi; Kasamatsu, Tadashi; Hirota, Kazuhiro; Tsuda, Hitoshi; Ikewaki, Katsunori; Asano, Tomohiko
2015-03-01
Purpose: Photoacoustic imaging (PAI) enables one to visualize the distribution of hemoglobin and acquire a map of microvessels without using contrast agents. The purpose of our study is to develop a clinically applicable PAI system integrated with a clinical ultrasound (US) array system with handheld PAI probes providing coregistered PAI and US images. Clinical research trials were performed to evaluate the performance and feasibility of clinical value. Materials and Methods: We developed two types of handheld PAI probes: a linear PAI probe combining a conventional linear-array US probe with optical illumination and a transrectal ultrasonography (TRUS)-type PAI probe. We performed experiments with Japanese white rabbits and conducted clinical research trials of urology and vascular medicine with the approval of the medical human ethics committee of the National Defense Medical College. Results: We successfully acquired high-dynamic-range images of the vascular network ranging from capillaries to landmark arteries and identified the femoral vein, deep femoral vein, and great saphenous vein of rabbits. These major vessels in the rabbits groin are surrounded with microvessels connected to each other. Periprostatic microvessels were monitored during radical prostatectomy for localized prostate cancer and they were colocalized with nerve fibers, and their distribution was consistent with the corresponding PAI. The TRUS-type PAI probe clearly demonstrated the location and extent of the neurovascular bundle (NVB) better than does TRUS alone. Conclusions: The system, which can obtain a PAI, a US image, and a merged image, was innovatively designed so that medical doctors can easily find the location without any prior knowledge or extended skills to analyze the obtained images. Our pilot feasibility study confirms that PAI could be an imaging modality useful in the screening study and diagnostic biopsy.
Gonenc, Berk; Chae, Jeremy; Gehlbach, Peter; Taylor, Russell H.; Iordachita, Iulian
2017-01-01
Retinal vein cannulation is a technically demanding surgical procedure where therapeutic agents are injected into the retinal veins to treat occlusions. The clinical feasibility of this approach has been largely limited by the technical challenges associated with performing the procedure. Among the challenges to successful vein cannulation are identifying the moment of venous puncture, achieving cannulation of the micro-vessel, and maintaining cannulation throughout drug delivery. Recent advances in medical robotics and sensing of tool-tissue interaction forces have the potential to address each of these challenges as well as to prevent tissue trauma, minimize complications, diminish surgeon effort, and ultimately promote successful retinal vein cannulation. In this paper, we develop an assistive system combining a handheld micromanipulator, called “Micron”, with a force-sensing microneedle. Using this system, we examine two distinct methods of precisely detecting the instant of venous puncture. This is based on measured tool-tissue interaction forces and also the tracked position of the needle tip. In addition to the existing tremor canceling function of Micron, a new control method is implemented to actively compensate unintended movements of the operator, and to keep the cannulation device securely inside the vein following cannulation. To demonstrate the capabilities and performance of our uniquely upgraded system, we present a multi-user artificial phantom study with subjects from three different surgical skill levels. Results show that our puncture detection algorithm, when combined with the active positive holding feature enables sustained cannulation which is most evident in smaller veins. Notable is that the active holding function significantly attenuates tool motion in the vein, thereby reduces the trauma during cannulation. PMID:28946634
Müller, Joachim; Putora, Paul Martin; Schneider, Tino; Zeisel, Christoph; Brutsche, Martin; Baty, Florent; Markus, Alexander; Kick, Jochen
2016-09-01
Radioactive marking can be a valuable extension to minimally invasive surgery. The technique has been clinically applied in procedures involving sentinel lymph nodes, parathyroidectomy as well as interventions in thoracic surgery. Improvements in equipment and techniques allow one to improve the limits. Pulmonary nodules are frequently surgically removed for diagnostic or therapeutic reasons; here video-assisted thoracoscopic surgery (VATS) is the preferred technique. VATS might be impossible with nodules that are small or located deep in the lung. In this study, we examined the clinical application and safety of employing the newly developed handheld single photon emission tomography (handheld SPECT) device in combination with CT-guided radioactive marking of pulmonary nodules. In this pilot study, 10 subjects requiring surgical resection of a pulmonary nodule were included. The technique involved CT-guided marking of the target nodule with a 20-G needle, with subsequent injection of 25-30 MBq (effective: 7-14 MBq) Tc-99m MAA (Macro Albumin Aggregate). Quality control was made with conventional SPECT-CT to confirm the correct localization and exclude possible complications related to the puncture procedure. VATS was subsequently carried out using the handheld SPECT to localize the radioactivity intraoperatively and therefore the target nodule. A 3D virtual image was superimposed on the intraoperative visual image for surgical guidance. In 9 of the 10 subjects, the radioactive application was successfully placed directly in or in the immediate vicinity of the target nodule. The average size of the involved nodules was 9 mm (range 4-15). All successfully marked nodules were subsequently completely excised (R0) using VATS. The procedure was well tolerated. An asymptomatic clinically insignificant pneumothorax occurred in 5 subjects. Two subjects were found to have non-significant discrete haemorrhage in the infiltration canal of the needle. In a single subject, the radioactive marking was unsuccessful because the radioactivity spread into the pleural space. In our series of 10 patients, it was demonstrated that using handheld SPECT in conjunction with VATS to remove radioactively marked pulmonary nodules is feasible. The combination of proven surgical techniques with a novel localization device (handheld SPECT) allowed successful VATS excision of pulmonary nodules which, due to their localization and small size, would typically have required thoracotomy. ClinicalTrials.gov, NCT02050724, Public 01/29/214, Joachim Müller. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Toward the Style of the Community Change Educator.
ERIC Educational Resources Information Center
Franklin, Richard
Variations and implications of change agents' patterns or styles of interaction with client systems (individuals, groups, or multigroups) are discussed. Five styles are defined: (1) the instructor, who imparts information to clients and interacts only with his agency; (2) the paterfamilias, who exercises personal, paternalistic influence and…
Wasielewski, Noah J; Kotsko, Kevin M
2007-01-01
Objective: To critically review evidence for the effectiveness of eccentric exercise to treat lower extremity tendinoses. Data Sources: Databases used to locate randomized controlled trials (RCTs) included PubMed (1980–2006), CINAHL (1982–2006), Web of Science (1995–2006), SPORT Discus (1980–2006), Physiotherapy Evidence Database (PEDro), and the Cochrane Collaboration Database. Key words included tendon, tendonitis, tendinosis, tendinopathy, exercise, eccentric, rehabilitation, and therapy. Study Selection: The criteria for trial selection were (1) the literature was written in English, (2) the research design was an RCT, (3) the study participants were adults with a clinical diagnosis of tendinosis, (4) the outcome measures included pain or strength, and (5) eccentric exercise was used to treat lower extremity tendinosis. Data Extraction: Specific data were abstracted from the RCTs, including eccentric exercise protocol, adjunctive treatments, concurrent physical activity, and treatment outcome. Data Synthesis: The calculated post hoc statistical power of the selected studies (n = 11) was low, and the average methodologic score was 5.3/10 based on PEDro criteria. Eccentric exercise was compared with no treatment (n = 1), concentric exercise (n = 5), an alternative eccentric exercise protocol (n = 1), stretching (n = 2), night splinting (n = 1), and physical agents (n = 1). In most trials, tendinosis-related pain was reduced with eccentric exercise over time, but only in 3 studies did eccentric exercise decrease pain relative to the control treatment. Similarly, the RCTs demonstrated that strength-related measures improved over time, but none revealed significant differences relative to the control treatment. Based on the best evidence available, it appears that eccentric exercise may reduce pain and improve strength in lower extremity tendinoses, but whether eccentric exercise is more effective than other forms of therapeutic exercise for the resolution of tendinosis symptoms remains questionable. PMID:18059998
Walking impairment in patients with multiple sclerosis: exercise training as a treatment option.
Motl, Robert W; Goldman, Myla D; Benedict, Ralph H B
2010-11-16
Multiple sclerosis (MS) is a chronic disease of the central nervous system that culminates in the progression of physical and cognitive disability over time. Walking impairment is a ubiquitous feature of MS and a sentinel characteristic of the later or advanced stages of the disease. This paper presents a conceptual rationale along with empirical evidence for exercise training as a rehabilitation approach for managing walking impairment and improving walking function in persons with MS. Conceptually, MS is associated with a decrease in physical activity, which, in turn, can result in deconditioning across multiple domains of physiological functioning. The resulting deconditioning feeds back and further drives physical inactivity until a threshold is reached that likely initiates the progression of walking impairment in MS. Empirically, physical activity and exercise training have been associated with beneficial effects on walking function in persons with MS. This is based on cross-sectional, longitudinal, and experimental research that included diversity in the breadth of measures of walking, persons with MS, and exercise/physical activity characteristics. Of particular importance, future researchers might consider examining the combinatory effects of exercise training plus pharmacological agents on walking mobility in MS. Collectively, exercise training and physical activity might hold significant potential for the management of progressive mobility disability in MS.
De Mello, M T; Esteves, A M; Tufik, S
2004-04-01
Randomized controlled trial of physical exercise and dopaminergic agonist in persons with spinal cord injury and periodic leg movement (PLM). The objective of the present study was to compare the effectiveness of physical exercise and of a dopaminergic agonist in reducing the frequency of PLM. Centro de Estudos em Psicobiologia e Exercício. Universidade Federal de São Paulo, Brazil. A total of 13 volunteers (mean age: 31.6+/-8.3 years) received L-DOPA (200 mg) and benserazide (50 mg) 1 h before sleeping time for 30 days and were then submitted to a physical exercise program on a manual bicycle ergometer for 45 days (3 times a week). Both L-DOPA administration (35.11-19.87 PLM/h, P<0.03) and physical exercise (35.11-18.53 PLM/h, P<0.012) significantly reduced PLM; however, no significant difference was observed between the two types of treatment. The two types of treatment were found to be effective in the reduction of PLM; however, physical exercise is indicated as the first treatment approach, while dopaminergic agonists or other drugs should only be recommended for patients who do not respond to this type of treatment.
Moderate treadmill exercise prevents oxidative stress-induced anxiety-like behavior in rats.
Salim, Samina; Sarraj, Nada; Taneja, Manish; Saha, Kaustuv; Tejada-Simon, Maria Victoria; Chugh, Gaurav
2010-04-02
Recent work has suggested correlation of oxidative stress with anxiety-like behavior. There also is evidence for anxiolytic effects of physical exercise. However, a direct role of oxidative stress in anxiety is not clear and a protective role of physical exercise in oxidative stress-mediated anxiety has never been addressed. In this study, we have utilized rats to test direct involvement of oxidative stress with anxiety-like behavior and have identified oxidative stress mechanisms likely involved in anxiolytic effects of physical exercise. Intraperitoneal injections at non-toxic dose of l-buthionine-(S,R)-sulfoximine (BSO), an agent that increases oxidative stress markers, increased anxiety-like behavior of rats compared to vehicle-treated control rats. Prior 2 weeks treatment with the antioxidant, tempol attenuated BSO-induced anxiety-like behavior of rats suggesting a role of oxidative stress in this phenomenon. Moreover, moderate treadmill exercise prevented BSO-induced anxiety-like behavior of rats and also prevented BSO-mediated increase in oxidative stress markers in serum, urine and brain tissue homogenates from hippocampus, amygdala and locus coeruleus. Thus increasing oxidative stress increases anxiety-like behavior of rats. Moreover, antioxidant or treadmill exercise training both reduce oxidative stress in the rat brain regions implicated in anxiety response and prevent anxiety-like behavior of rats. Published by Elsevier B.V.
Pyridostigmine bromide does not alter thermoregulation during exercise in cold air
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberts, D.E.; Sawka, M.N.; Young, A.J.
1994-12-31
This study examined the effects of acute and chronic pyridostigmine bromide (PB) administration on thermoregulatory and metabolic responses to exercise in cold air (5 C). Seven healthy men completed two 7-day trials in a double-blind, crossover experimental design: during one trial they received PB (30 mg three times daily) and during the other trial they received placebo. For each trial, subjects attempted four (3 h) exercise tests: low-intensity exercise (25% Vo2max) and moderate- intensity exercise (-50% Vo2max), on days 2 and 3 and again on days 6 and 7. Metabolic rate, body temperatures, and venous blood samples were obtained beforemore » and during exercise. Red blood cell acerylcholinesterase inhibition induced by PB increased (p < 0.05) from 34% on day I to 43% on days 3-7 Metabolic rate, body temperatures, and regional heat conductance responses were not different between trials. Plasma glucose, glycerol, free fatty acid, lactate, sodium, and potassium concentrations were not different between trials. In addition. differences were not found between acute and chronic experiments for any thermoregulatory or metabolic responses. These findings demonstrate that the PB dosage used by military personnel, as a pharmacological defense against nerve-agent poisoning. should not cause any adverse thermoregulatory or metabolic effects during moderate activity in cold climates.« less
ERIC Educational Resources Information Center
O'Rourke, John; Main, Susan; Ellis, Michelle
2013-01-01
Games technology in the form of hand-held game consoles (HGCs) when focussed on specific academic skill development has the capacity to engage students in learning and in turn produce positive academic results. This current research explores teacher perceptions of the implementation of HGCs to enhance the development of mental maths skills (namely…
Zuzek, Crystal
2013-04-01
In 2011, the National Transportation Safety Board urged all states to ban the use of portable electronic devices while driving, including hand-held and hands-free devices. Texting while driving concerns several Texas legislators, who have filed bills, backed by the Texas Medical Association, to ban the practice. TMA physicians recognize that the use of hand-held and hands-free devices and other factors associated with distracted driving affect their patients' safety.
ERIC Educational Resources Information Center
Vitz, Ed
2010-01-01
A handheld digital microscope (HDM) interfaced to a computer with a presentation projector is used to project an out-of-focus yellow patch on the screen, then the patch is brought into focus to show that, paradoxically, there are red and green but no yellow pixels. Chromaticity diagrams are used to discuss this observation and spectroscopic…
ERIC Educational Resources Information Center
Nordness, Philip D.; Haverkost, Ann; Volberding, Annette
2011-01-01
The effect of a mathematic flashcard application on a hand-held computing device was examined across three individual second grade students with learning and behavioral disabilities. All of the students improved their subtraction scores by an average of 17% as measured by the district-created, curriculum-based assessment. The results of this study…
DataPlus - a revolutionary applications generator for DOS hand-held computers
David Dean; Linda Dean
2000-01-01
DataPlus allows the user to easily design data collection templates for DOS-based hand-held computers that mimic clipboard data sheets. The user designs and tests the application on the desktop PC and then transfers it to a DOS field computer. Other features include: error checking, missing data checks, and sensor input from RS-232 devices such as bar code wands,...
ERIC Educational Resources Information Center
Pegrum, Mark; Oakley, Grace; Faulkner, Robert
2013-01-01
This paper reports on the adoption of mobile handheld technologies in ten Western Australian independent schools, based on interviews with staff conducted in 2011. iPads were the most popular device, followed by iPod Touches and iPhones. Class sets were common at lower levels, with 1:1 models becoming increasingly common at higher levels. Mobile…
ERIC Educational Resources Information Center
Gielen, Nina
2010-01-01
This report describes a conversion experiment and subsequent reader survey conducted by the American Council of Learned Societies (ACLS) Humanities E-Book (HEB) in late 2009 and early 2010 to assess the viability of using scholarly monographs with handheld e-readers. As sample content, HEB selected six titles from its own online collection, three…
Personal Devices in Public Settings: Lessons Learned from an iPod Touch/iPad Project
ERIC Educational Resources Information Center
Crichton, Susan; Pegler, Karen; White, Duncan
2012-01-01
Our paper reports findings from a two-phase deployment of iPod Touch and iPad devices in a large, urban Canadian school board. The purpose of the study was to gain an understanding of the infrastructure required to support handheld devices in classrooms; the opportunities and challenges teachers face as they begin to use handheld devices for…
ERIC Educational Resources Information Center
Ren, Xiangshi; Zhou, Xiaolei
2011-01-01
Many handheld devices with stylus pens are available in the market; however, there have been few studies which examine the effects of the size of the stylus pen on user performance and subjective preferences for handheld device interfaces for various age groups. Two experiments (pen-length experiment and pen-tip width/pen-width experiment) were…
ERIC Educational Resources Information Center
What Works Clearinghouse, 2014
2014-01-01
The 2014 study, "Conceptualizing Astronomical Scale: Virtual Simulations on Handheld Tablet Computers Reverse Misconceptions," examined the effects of using the true-to-scale (TTS) display mode versus the orrery display mode in the iPad's Solar Walk software application on students' knowledge of the Earth's place in the solar system. The…
Jephcott, C; Grummet, J; Nguyen, N; Spruyt, O
2018-05-01
Methoxyflurane delivered via a hand-held inhaler is a proven analgesic which has been used in Australasia for emergency relief of trauma associated pain since the 1970s. The agent is self-administered by the patient under the supervision of trained personnel. More than 5 million patients have received inhaled methoxyflurane without significant side effects. Methoxyflurane is also licensed in Australasia for the relief of pain in monitored conscious patients requiring analgesia for minor surgical procedures. Recent clinical studies undertaken in a variety of outpatient settings, including colonoscopy, prostate biopsy, dental procedures, bone marrow biopsy, and the management of burns dressings, indicate that inhaled methoxyflurane has significant analgesic activity, without producing deep sedation or respiratory depression. Return to full psychomotor activity is rapid. Thus, methoxyflurane may be a suitable and well-tolerated alternative to traditional i.v. sedative agents for outpatient medical and surgical procedures. There are direct advantages to the patient in terms of rapid recovery and an early return to normal activities, and significant benefits for outpatient departments in terms of cost saving and rate of throughput. Further randomised controlled trials comparing the efficacy, safety, and cost-effectiveness of inhaled methoxyflurane against traditional i.v. sedative techniques are currently in progress. Copyright © 2018 British Journal of Anaesthesia. All rights reserved.
2013-01-01
Background Handheld computers for data collection (HCDC) and management have become increasingly common in health research. However, current knowledge about the use of HCDC in health research in China is very limited. In this study, we administered a survey to a hard-to-reach population in China using HCDC and assessed the acceptability and adoption of HCDC in China. Methods Handheld computers operating Windows Mobile and Questionnaire Development Studio (QDS) software (Nova Research Company) were used for this survey. Questions on tobacco use and susceptibility were drawn from the Global Adult Tobacco Survey (GATS) and other validated instruments, and these were programmed in Chinese characters by local staff. We conducted a half-day training session for survey supervisors and a three-day training session for 20 interviewers and 9 supervisors. After the training, all trainees completed a self-assessment of their skill level using HCDC. The main study was implemented in fall 2010 in 10 sites, with data managed centrally in Beijing. Study interviewers completed a post-survey evaluation questionnaire on the acceptability and utility of HCDC in survey research. Results Twenty-nine trainees completed post-training surveys, and 20 interviewers completed post-data collection questionnaires. After training, more than 90% felt confident about their ability to collect survey data using HCDC, to transfer study data from a handheld computer to a laptop, and to encrypt the survey data file. After data collection, 80% of the interviewers thought data collection and management were easy and 60% of staff felt confident they could solve problems they might encounter. Overall, after data collection, nearly 70% of interviewers reported that they would prefer to use handheld computers for future surveys. More than half (55%) felt the HCDC was a particularly useful data collection tool for studies conducted in China. Conclusions We successfully conducted a health-related survey using HCDC. Using handheld computers for data collection was a feasible, acceptable, and preferred method by Chinese interviewers. Despite minor technical issues that occurred during data collection, HCDC is a promising methodology to be used in survey-based research in China. PMID:23802988
In-car cell phone use and hazards following hands free legislation.
Rajalin, Sirpa; Summala, Heikki; Pöysti, Leena; Anteroinen, Pasi; Porter, Bryan E
2005-09-01
A new law took effect in Finland at the beginning of 2003 which prohibits the handheld use of mobile phones while driving a motor vehicle. The purpose of this study was to assess the impact of the law on phone usage and self-reported safety during the first few months and 16 months later to determine whether the initial level of compliance with the law had been sustained. Data were collected by Gallup home poll before (spring 2002) and after legislation took effect (spring 2003 and 2004). A representative sample of drivers who owned a cell phone (n = 836 to 966) was interviewed each time. On-road observations were also collected in four cities for 2003 and 2004. Just after the law, 97% of drivers were aware of the new hands free legislation. In sharp contrast to the pre-law rate of 16%, 43% reported not using the phone while driving immediately after the law and 41% one year later. The occasional users especially reduced their use of phones while driving. The law was correlated to reductions in self-reported handheld use of cell phones while driving, from 55.6% pre-law to 15.2% immediately after passage. In spite of this change, however, the hands free legislation did not reduce self-reported involvement of Finnish drivers in phone-related hazards. Handheld usage was still lower in 2004 than pre-law (20.0%), but the 32% increase from 2003 was significant. Observational data collected in Finland in 2003 and 2004 showed an even higher upward trend in handheld use (87% increase, from 3.1% to 5.8%; pre-law data were not available), and matched a similar increase reported by McCartt and Geary (2004) in their observational evaluation of New York's handheld mobile phone law. The self-reports indicate that the hands-free law reduced handheld phone use, among occasional users especially, but did not reduce phone-related hazards. The effect of the law on phone use substantially declined within one year.
Huang, Yong; Furtmüller, Georg J.; Tong, Dedi; Zhu, Shan; Lee, W. P. Andrew; Brandacher, Gerald; Kang, Jin U.
2014-01-01
Purpose To demonstrate the feasibility of a miniature handheld optical coherence tomography (OCT) imager for real time intraoperative vascular patency evaluation in the setting of super-microsurgical vessel anastomosis. Methods A novel handheld imager Fourier domain Doppler optical coherence tomography based on a 1.3-µm central wavelength swept source for extravascular imaging was developed. The imager was minimized through the adoption of a 2.4-mm diameter microelectromechanical systems (MEMS) scanning mirror, additionally a 12.7-mm diameter lens system was designed and combined with the MEMS mirror to achieve a small form factor that optimize functionality as a handheld extravascular OCT imager. To evaluate in-vivo applicability, super-microsurgical vessel anastomosis was performed in a mouse femoral vessel cut and repair model employing conventional interrupted suture technique as well as a novel non-suture cuff technique. Vascular anastomosis patency after clinically successful repair was evaluated using the novel handheld OCT imager. Results With an adjustable lateral image field of view up to 1.5 mm by 1.5 mm, high-resolution simultaneous structural and flow imaging of the blood vessels were successfully acquired for BALB/C mouse after orthotopic hind limb transplantation using a non-suture cuff technique and BALB/C mouse after femoral artery anastomosis using a suture technique. We experimentally quantify the axial and lateral resolution of the OCT to be 12.6 µm in air and 17.5 µm respectively. The OCT has a sensitivity of 84 dB and sensitivity roll-off of 5.7 dB/mm over an imaging range of 5 mm. Imaging with a frame rate of 36 Hz for an image size of 1000(lateral)×512(axial) pixels using a 50,000 A-lines per second swept source was achieved. Quantitative vessel lumen patency, lumen narrowing and thrombosis analysis were performed based on acquired structure and Doppler images. Conclusions A miniature handheld OCT imager that can be used for intraoperative evaluation of microvascular anastomosis was successfully demonstrated. PMID:25474742
Wan, Xia; Raymond, H Fisher; Wen, Tiancai; Ding, Ding; Wang, Qian; Shin, Sanghyuk S; Yang, Gonghuan; Chai, Wanxing; Zhang, Peng; Novotny, Thomas E
2013-06-26
Handheld computers for data collection (HCDC) and management have become increasingly common in health research. However, current knowledge about the use of HCDC in health research in China is very limited. In this study, we administered a survey to a hard-to-reach population in China using HCDC and assessed the acceptability and adoption of HCDC in China. Handheld computers operating Windows Mobile and Questionnaire Development Studio (QDS) software (Nova Research Company) were used for this survey. Questions on tobacco use and susceptibility were drawn from the Global Adult Tobacco Survey (GATS) and other validated instruments, and these were programmed in Chinese characters by local staff. We conducted a half-day training session for survey supervisors and a three-day training session for 20 interviewers and 9 supervisors. After the training, all trainees completed a self-assessment of their skill level using HCDC. The main study was implemented in fall 2010 in 10 sites, with data managed centrally in Beijing. Study interviewers completed a post-survey evaluation questionnaire on the acceptability and utility of HCDC in survey research. Twenty-nine trainees completed post-training surveys, and 20 interviewers completed post-data collection questionnaires. After training, more than 90% felt confident about their ability to collect survey data using HCDC, to transfer study data from a handheld computer to a laptop, and to encrypt the survey data file. After data collection, 80% of the interviewers thought data collection and management were easy and 60% of staff felt confident they could solve problems they might encounter. Overall, after data collection, nearly 70% of interviewers reported that they would prefer to use handheld computers for future surveys. More than half (55%) felt the HCDC was a particularly useful data collection tool for studies conducted in China. We successfully conducted a health-related survey using HCDC. Using handheld computers for data collection was a feasible, acceptable, and preferred method by Chinese interviewers. Despite minor technical issues that occurred during data collection, HCDC is a promising methodology to be used in survey-based research in China.
Haller, Guy; Haller, Dagmar M; Courvoisier, Delphine S; Lovis, Christian
2009-01-01
To compare users' speed, number of entry errors and satisfaction in using two current devices for electronic data collection in clinical research: handheld and laptop computers. The authors performed a randomized cross-over trial using 160 different paper-based questionnaires and representing altogether 45,440 variables. Four data coders were instructed to record, according to a random predefined and equally balanced sequence, the content of these questionnaires either on a laptop or on a handheld computer. Instructions on the kind of device to be used were provided to data-coders in individual sealed and opaque envelopes. Study conditions were controlled and the data entry process performed in a quiet environment. The authors compared the duration of the data recording process, the number of errors and users' satisfaction with the two devices. The authors divided errors into two separate categories, typing and missing data errors. The original paper-based questionnaire was used as a gold-standard. The overall duration of the recording process was significantly reduced (2.0 versus 3.3 min) when data were recorded on the laptop computer (p < 0.001). Data accuracy also improved. There were 5.8 typing errors per 1,000 entries with the laptop compared to 8.4 per 1,000 with the handheld computer (p < 0.001). The difference was even more important for missing data which decreased from 22.8 to 2.9 per 1,000 entries when a laptop was used (p < 0.001). Users found the laptop easier, faster and more satisfying to use than the handheld computer. Despite the increasing use of handheld computers for electronic data collection in clinical research, these devices should be used with caution. They double the duration of the data entry process and significantly increase the risk of typing errors and missing data. This may become a particularly crucial issue in studies where these devices are provided to patients or healthcare workers, unfamiliar with computer technologies, for self-reporting or research data collection processes.
Haller, Guy; Haller, Dagmar M.; Courvoisier, Delphine S.; Lovis, Christian
2009-01-01
Objective To compare users' speed, number of entry errors and satisfaction in using two current devices for electronic data collection in clinical research: handheld and laptop computers. Design The authors performed a randomized cross-over trial using 160 different paper-based questionnaires and representing altogether 45,440 variables. Four data coders were instructed to record, according to a random predefined and equally balanced sequence, the content of these questionnaires either on a laptop or on a handheld computer. Instructions on the kind of device to be used were provided to data-coders in individual sealed and opaque envelopes. Study conditions were controlled and the data entry process performed in a quiet environment. Measurements The authors compared the duration of the data recording process, the number of errors and users' satisfaction with the two devices. The authors divided errors into two separate categories, typing and missing data errors. The original paper-based questionnaire was used as a gold-standard. Results The overall duration of the recording process was significantly reduced (2.0 versus 3.3 min) when data were recorded on the laptop computer (p < 0.001). Data accuracy also improved. There were 5.8 typing errors per 1,000 entries with the laptop compared to 8.4 per 1,000 with the handheld computer (p < 0.001). The difference was even more important for missing data which decreased from 22.8 to 2.9 per 1,000 entries when a laptop was used (p < 0.001). Users found the laptop easier, faster and more satisfying to use than the handheld computer. Conclusions Despite the increasing use of handheld computers for electronic data collection in clinical research, these devices should be used with caution. They double the duration of the data entry process and significantly increase the risk of typing errors and missing data. This may become a particularly crucial issue in studies where these devices are provided to patients or healthcare workers, unfamiliar with Computer Technologies, for self-reporting or research data collection processes. PMID:19567799
Momentary affect predicts bodily movement in daily life: an ambulatory monitoring study.
Schwerdtfeger, Andreas; Eberhardt, Ragna; Chmitorz, Andrea; Schaller, Eva
2010-10-01
There is converging evidence that physical activity influences affective states. It has been found that aerobic exercise programs can significantly diminish negative affect. Moreover, among healthy individuals, moderate levels of physical activity seem to increase energetic arousal and positive affect. However, the predictive utility of affective states for bodily movement has rarely been investigated. In this study, we examined whether momentarily assessed affect is associated with bodily movement in everyday life. Using a previously published data set (Schwerdtfeger, Eberhardt, & Chmitorz, 2008), we reanalyzed 12-hr ecological momentary assessment (EMA) data from 124 healthy volunteers. Electronic momentary positive-activated affect (EMA-PAA) and negative affect (EMA-NA) were assessed via handheld computers, and bodily movement was recorded via accelerosensors. Generalized linear mixed models were calculated. Results indicated that EMAPAA increases were accompanied by bodily movement increases of varying intensity. EMA-NA was also positively associated with increases in certain kinds of bodily movement. In light of previous research, this finding suggests that affect and bodily movement may have circular effects on each other.
Effects of rehabilitation management on gastric emptying function in older adults with diabetes.
Shao, Z M; Yao, J F; Chen, J; Yu, Z W; Yu, X F; Zheng, J J; Tang, X
2014-01-24
The relationship between gastric emptying dysfunction and blood glucose concentration in elderly with type 2 diabetes mellitus was investigated, and the effect of rehabilitation exercise prescription training on gastric emptying in the geriatric diabetic patients was evaluated. A total of 160 older type 2 diabetic adults and 30 cases of non-diabetic patients were studied with regard to the gastric half emptying time (GET1/2) of solid meals radiolabelled with 99mTc. Eighty delayed gastric emptying diabetic patients were randomly divided into 4 four groups: rehabilitation exercise + mosapride group (N = 20), rehabilitation exercise group (N = 20), mosapride group (N = 20), and control group (N = 20). The level of blood glucose was measured every six months in a two-year follow-up. The solid GET1/2 of regulated blood glycemic control patients showed no statistically significant differences from non-diabetic patients (P > 0.05). However, the value for poor blood glycemic control patients exhibited significant statistical differences compared with both non-diabetic (P < 0.01) and regulated blood glycemic control group patients (P < 0.01). It showed that the gastric emptying time improved in the rehabilitation exercise group, mosapride group and rehabilitation exercise group + mosapride group after two years of treatment (P < 0.05). Fasting blood glucose in both rehabilitation exercise group and rehabilitation exercise + mosapride group was significantly decreased. Postprandial blood glucose in the rehabilitation exercise group, mosapride group, rehabilitation exercise group + mosapride group was significantly decreased. High blood glucose level can delay gastric emptying in older type 2 diabetic patients. Gastric emptying and blood glucose control affect each other. It was shown that appropriate rehabilitation exercise combined with prokinetic agent may improve gastric emptying in some geriatric type 2 diabetic patients and help control their blood glucose.
Desensitization of the cough reflex by exercise and voluntary isocapnic hyperpnea.
Lavorini, Federico; Fontana, Giovanni A; Chellini, Elisa; Magni, Chiara; Duranti, Roberto; Widdicombe, John
2010-05-01
Little is known about the effects of exercise on the sensory and cognitive aspects of coughing evoked by inhalation of tussigenic agents. The threshold for the cough reflex induced by inhalation of increasing nebulizer outputs of ultrasonically nebulized distilled water (fog), an index of cough reflex sensitivity, was assessed in twelve healthy humans in control conditions, during exercise and during voluntary isocapnic hyperpnea (VIH) at the same ventilatory level as the exercise. The intensity of the urge to cough (UTC), a cognitive component of coughing, was recorded throughout the trials on a linear scale. The relationships between inhaled fog nebulizer outputs and the correspondingly evoked UTC values, an index of the perceptual magnitude of the UTC sensitivity, were also calculated. Cough appearance was always assessed audiovisually. At an exercise level of 80% of anaerobic threshold, the median cough threshold was increased from a control value of 0.73 to 2.22 ml/min (P<0.01), i.e., cough sensitivity was downregulated. With VIH, the threshold increased from 0.73 to 2.22 ml/min (P<0.01), a similar downregulation. With exercise and VIH compared with control, mean UTC values at cough threshold were unchanged, i.e., control, 3.83 cm; exercise, 3.12 cm; VIH, 4.08 cm. The relationship of the fog nebulizer output/UTC value was linear in control conditions and logarithmic during both exercise and VIH. The perception of the magnitude of the UTC seems to be influenced by signals or sensations arising from exercising limb and thoracic muscles and/or by higher nervous (cortical) mechanisms. The results indicate that the adjustments brought into action by exercise-induced or voluntary hyperpnea exert inhibitory influences on the sensory and cognitive components of fog-induced cough.
Mitochondria-targeted nutraceuticals in sports medicine: a new perspective.
Ostojic, Sergej M
2017-01-01
Since mitochondria have been recognized as the cells' key organelles involved in the energy utilization during exercise, targeting the organelle with specifically designed compounds (mitochondria-targeted nutraceuticals, MTNs) may have a great promise in the prevention and treatment of heavy exercise-related mitochondrial dysfunction. In vitro studies suggested that MTNs have antioxidant effects at the molecular level, and might boost mitochondrial biogenesis and organelle bioenergetics, with both processes are known to positively affect exercise performance and recovery. However, while there are a number of different MTNs evaluated for a potential benefit as a therapy for mitochondria-related diseases and conditions, only few human studies evaluated the possible impact of novel MTNs in the field of sports medicine. This mini review summarizes recent research findings regarding the efficacy of different mitochondria-targeted nutritional agents, emphasizing their roles in sports medicine.
Site-Specific Antioxidative Therapy for Prevention of Atherosclerosis and Cardiovascular Disease
Otani, Hajime
2013-01-01
Oxidative stress has been implicated in pathophysiology of aging and age-associated disease. Antioxidative medicine has become a practice for prevention of atherosclerosis. However, limited success in preventing cardiovascular disease (CVD) in individuals with atherosclerosis using general antioxidants has prompted us to develop a novel antioxidative strategy to prevent atherosclerosis. Reducing visceral adipose tissue by calorie restriction (CR) and regular endurance exercise represents a causative therapy for ameliorating oxidative stress. Some of the recently emerging drugs used for the treatment of CVD may be assigned as site-specific antioxidants. CR and exercise mimetic agents are the choice for individuals who are difficult to continue CR and exercise. Better understanding of molecular and cellular biology of redox signaling will pave the way for more effective antioxidative medicine for prevention of CVD and prolongation of healthy life span. PMID:23738041
NASA Astrophysics Data System (ADS)
Joshi, V.; Wigdahl, J.; Nemeth, S.; Zamora, G.; Ebrahim, E.; Soliz, P.
2018-02-01
Retinal abnormalities associated with hypertensive retinopathy are useful in assessing the risk of cardiovascular disease, heart failure, and stroke. Assessing these risks as part of primary care can lead to a decrease in the incidence of cardiovascular disease-related deaths. Primary care is a resource limited setting where low cost retinal cameras may bring needed help without compromising care. We compared a low-cost handheld retinal camera to a traditional table top retinal camera on their optical characteristics and performance to detect hypertensive retinopathy. A retrospective dataset of N=40 subjects (28 with hypertensive retinopathy, 12 controls) was used from a clinical study conducted at a primary care clinic in Texas. Non-mydriatic retinal fundus images were acquired using a Pictor Plus hand held camera (Volk Optical Inc.) and a Canon CR1-Mark II tabletop camera (Canon USA) during the same encounter. The images from each camera were graded by a licensed optometrist according to the universally accepted Keith-Wagener-Barker Hypertensive Retinopathy Classification System, three weeks apart to minimize memory bias. The sensitivity of the hand-held camera to detect any level of hypertensive retinopathy was 86% compared to the Canon. Insufficient photographer's skills produced 70% of the false negative cases. The other 30% were due to the handheld camera's insufficient spatial resolution to resolve the vascular changes such as minor A/V nicking and copper wiring, but these were associated with non-referable disease. Physician evaluation of the performance of the handheld camera indicates it is sufficient to provide high risk patients with adequate follow up and management.
Data collection outcomes comparing paper forms with PDA forms in an office-based patient survey.
Galliher, James M; Stewart, Thomas V; Pathak, Paramod K; Werner, James J; Dickinson, L Miriam; Hickner, John M
2008-01-01
We compared the completeness of data collection using paper forms and using electronic forms loaded on handheld computers in an office-based patient interview survey conducted within the American Academy of Family Physicians National Research Network. We asked 19 medical assistants and nurses in family practices to administer a survey about pneumococcal immunizations to 60 older adults each, 30 using paper forms and 30 using electronic forms on handheld computers. By random assignment, the interviewers used either the paper or electronic form first. Using multilevel analyses adjusted for patient characteristics and clustering of forms by practice, we analyzed the completeness of the data. A total of 1,003 of the expected 1,140 forms were returned to the data center. The overall return rate was better for paper forms (537 of 570, 94%) than for electronic forms (466 of 570, 82%) because of technical difficulties experienced with electronic data collection and stolen or lost handheld computers. Errors of omission on the returned forms, however, were more common using paper forms. Of the returned forms, only 3% of those gathered electronically had errors of omission, compared with 35% of those gathered on paper. Similarly, only 0.04% of total survey items were missing on the electronic forms, compared with 3.5% of the survey items using paper forms. Although handheld computers produced more complete data than the paper method for the returned forms, they were not superior because of the large amount of missing data due to technical difficulties with the hand-held computers or loss or theft. Other hardware solutions, such as tablet computers or cell phones linked via a wireless network directly to a Web site, may be better electronic solutions for the future.
NASA Astrophysics Data System (ADS)
Leeburg, Kelsey C.; El-Haddad, Mohamed T.; Malone, Joseph D.; Terrones, Benjamin D.; Tao, Yuankai K.
2018-02-01
Scanning laser ophthalmoscopy (SLO) provides high-speed, noninvasive en face imaging of the retinal fundus. Optical coherence tomography (OCT) is the current "gold-standard" for ophthalmic diagnostic imaging and enables depth-resolved visualization of ophthalmic structures and image-based surrogate biomarkers of disease. We present a compact optical and mechanical design for handheld spectrally encoded coherence tomography and reflectometry (SECTR) for multimodality en face spectrally encoded reflectometry (SER) and cross-sectional OCT imaging. We custom-designed a double-pass telecentric scan lens, which halves the size of 4-f optical relays and allowed us to reduce the footprint of our SECTR scan-head by a factor of >2.7x (volume) over our previous design. The double-pass scan lens was optimized for diffraction-limited performance over a +/-10° scan field. SECTR optics and optomechanics were combined in a compact rapid-prototyped enclosure with dimensions 87 x 141.8 x 137 mm (w x h x d). SECTR was implemented using a custom-built 400 kHz 1050 nm swept-source. OCT and SER were simultaneously digitized on dual input channels of a 4 GS/s digitizer at 1.4 GS/s per channel. In vivo human en face SER and cross-sectional OCT images were acquired at 350 fps. OCT volumes of 1000 B-scans were acquired in 2.86 s. We believe clinical translation of our compact handheld design will benefit point-of-care ophthalmic diagnostics in patients who are unable to be imaged on conventional slit-lamp based systems, such as infants and the bedridden. When combined with multi-volumetric registration methods, handheld SECTR will have advantages in motion-artifact free imaging over existing handheld technologies.
Critical care procedure logging using handheld computers
Carlos Martinez-Motta, J; Walker, Robin; Stewart, Thomas E; Granton, John; Abrahamson, Simon; Lapinsky, Stephen E
2004-01-01
Introduction We conducted this study to evaluate the feasibility of implementing an internet-linked handheld computer procedure logging system in a critical care training program. Methods Subspecialty trainees in the Interdepartmental Division of Critical Care at the University of Toronto received and were trained in the use of Palm handheld computers loaded with a customized program for logging critical care procedures. The procedures were entered into the handheld device using checkboxes and drop-down lists, and data were uploaded to a central database via the internet. To evaluate the feasibility of this system, we tracked the utilization of this data collection system. Benefits and disadvantages were assessed through surveys. Results All 11 trainees successfully uploaded data to the central database, but only six (55%) continued to upload data on a regular basis. The most common reason cited for not using the system pertained to initial technical problems with data uploading. From 1 July 2002 to 30 June 2003, a total of 914 procedures were logged. Significant variability was noted in the number of procedures logged by individual trainees (range 13–242). The database generated by regular users provided potentially useful information to the training program director regarding the scope and location of procedural training among the different rotations and hospitals. Conclusion A handheld computer procedure logging system can be effectively used in a critical care training program. However, user acceptance was not uniform, and continued training and support are required to increase user acceptance. Such a procedure database may provide valuable information that may be used to optimize trainees' educational experience and to document clinical training experience for licensing and accreditation. PMID:15469577
Assessment of cyanide contamination in soils with a handheld mid-infrared spectrometer.
Soriano-Disla, José M; Janik, Leslie J; McLaughlin, Michael J
2018-02-01
We examined the feasibility of using handheld mid-infrared (MIR) Fourier-Transform infrared (FT-IR) instrumentation for detecting and analysing cyanide (CN) contamination in field contaminated soils. Cyanide spiking experiments were first carried out, in the laboratory, to test the sensitivity of infrared Fourier transform (DRIFT) spectrometry to ferro- and ferricyanide compounds across a range of reference soils and minerals. Both benchtop and handheld diffuse reflectance infrared spectrometers were tested. Excellent results were obtained for the reference soils and minerals, with the MIR outperforming the near-infrared (NIR) range. Spectral peaks characteristic of the -C≡N group were observed near 2062 and 2118cm -1 in the MIR region for the ferro- and ferricyanide compounds spiked into soils/minerals, respectively. In the NIR region such peaks were observed near 4134 and 4220cm -1 . Cyanide-contaminated samples were then collected in the field and analyzed with the two spectrometers to further test the applicability of the DRIFT technique for soils containing aged CN residues. The prediction of total CN in dry and ground contaminated soils using the handheld MIR instrument resulted in a coefficient of determination (R 2 ) of 0.88-0.98 and root mean square error of the cross-validation (RMSE) of 21-49mgkg -1 for a CN range of 0-611mgkg -1 . A major peak was observed in the MIR at about 2092cm -1 which was attributed to "Prussian Blue" (Fe 4 [Fe(CN) 6 ] 3 ·xH 2 O). These results demonstrate the potential of handheld DRIFT instrumentation as a promising alternative to the standard laboratory method to predict CN concentrations in contaminated field soils. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
Development of solid materials for UF 6 sampling: FY16 Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Nicholas; Savina, Joseph; Hebden, Andrew
2016-10-31
A handheld implementation of the ABACC-developed Cristallini method, which captures uranium hexafluoride samples as an inert salt, was organized in FY17 and succeeded in demonstrating the handheld sampler concept with reactive hexafluoride gases. The Cristallini method relies on the use of a hydrated substrate to react the incoming hexafluoride resulting in the formation of a stable uranyl fluoride salt. The Cristallini method has been demonstrated as a facility modification installed near the sampling tap of a gas centrifuge enrichment plant. While very successful in reducing the hazards of uranium hexafluoride sample, the method still takes a considerable amount of timemore » and can only be used in facilities where the apparatus has been installed; this arrangement generally prohibits the sampling of filled cylinders that have already exited the facility and have been deposited in the on-site tank storage yard. The handheld unit under development will allow the use of the Cristallini method at facilities that have not been converted as well as tanks in the storage yard. The handheld system utilizes an active vacuum system, rather than a passive vacuum system in the facility setup, to drive the uranium hexafluoride onto the adsorbing media. The handheld unit will be battery operated for fully autonomous operation and will include onboard pressure sensing and flushing capability. To date, the system concept of operations was demonstrated with tungsten hexafluoride that showed the active vacuum pump with multiple cartridges of adsorbing media was viable. Concurrently, the hardened prototype system was developed and tested; removable sample cartridges were developed (the only non-COTS component to date); and preparations were made for uranium tests and a domestic field test.« less