Y. Chen; S. J. Seybold
2013-01-01
Instar determination of field-collected insect larvae has generally been based on the analysis of head capsule width frequency distributions or bivariate plotting, but few studies have tested the validity of such methods. We used head capsules from exuviae of known instars of the beet armyworm, Spodoptera exigua (Hübner) (Lepidoptera: Noctuidae),...
Sieve efficiency in benthic sampling as related to chironomid head capsule width
Hudson, Patrick L.; Adams, Jean V.
1998-01-01
The width of the head capsule in chironomid larvae is the most important morphometric character controlling retention of specimens in sieving devices. Knowledge of the range in size of these widths within any chironomid community is fundamental to sampling and interpreting the resulting data. We present the head capsule widths of 30 species of chironomids and relate their size distribution to loss or retention in several experiments using graded sieve sizes. Based on our measurements and those found in the literature we found the head capsule width of fourth instars in half the chironomids species to be less than 350 I?m. Many species may never be collected with the commonly used U.S. Standard No. 30 sieve (589 I?m), and the No. 60 (246 I?m) screen appears to retain most species only qualitatively. We found 70 to 90% of the chironomid larvae and 19 to 34% of their biomass can pass through a No. 80 sieve (177 I?m). The implications of sieve loss and other factors affecting sieving efficiency are discussed.
Farder-Gomes, C F; Oliveira, M A; Gonçalves, P L; Gontijo, L M; Zanuncio, J C; Bragança, M A L; Pires, E M
2017-08-01
The leaf-cutting ant Atta sexdens Forel (Hymenoptera: Formicidae) is one of the most damaging agricultural pests in the Neotropics. Management strategies predominantly rely on the use of general insecticides. What is needed are more species-specific and environmentally friendly options. Parasitioids such as phorid flies (Diptera: Phoridae) may be one such option, but a greater understanding of the ecology of the flies and their ant hosts is essential to devise biological control strategies. Here we report parasitism rates, ant host size, parasitoid abundance per host and resultant sex ratios of two phorid species Apocephalus attophilus Borgmeier and Eibesfeldtphora tonhascai Brown parasitizing A.sexdens. The two species achieved parasitism rates of 1.48 and 1.46%, respectively and the pupal period was 14.7 ± 1.1 days and 22.1 ± 2.8 days, respectively. There was no significant difference between the head capsule width of ants parasitized by either A. attophilus or E. tonhascai. Likewise, there was no significant effect between the head capsule width of parasitized and unparasitized ants for both species. A significant positive correlation was found between the head capsule width of the parasitized ants and the number of adult parasitoids A. attophilus emerged. Ants parasitized by E. tonhascai survived significantly longer than those parasitized by A. attophilus. There was no significant effect of ant head width on the sex ratio of the offspring of either parasitoid species and no significant difference in the sex ratio (male: female) of their offspring. In summary, these data addressed here are important steps when considering natural enemies for biological control. Studying survival of the parasitized ants, parasitoid offspring sex ratio and host size preference allows for a better understanding of ant natural biological control in the field and can help in rearing of A. attophilus and E. tonhascai in laboratory.
Paul.L. Dallara; Mary.L. Flint; Steven. J. Seybold
2012-01-01
By measuring and analyzing larval head capsule widths, we determined that a northern California population of the walnut twig beetle, Pityophthorus juglandis Blackman (Coleoptera: Scolytidae), has three larval instars. We also developed rules to classify P. juglandis larval instars. Overlap in the ranges of widths among...
Tuan, Shu-Jen; Li, Nian-Jhen; Yeh, Chih-Chun
2015-10-01
Spodoptera litura (F.), an important polyphagous insect pest, attacks ca. 300 economic crops in dozens of countries. Investigations into its growth and development performance on different host plants can provide an understanding of the potential for increase of S. litura population in the field. We measured the development time, body weight, and head capsule width of S. litura larvae reared on cabbage, taro, peanut, and sesbania, a green manure. Larvae reared on cabbage ingested a significantly higher amount of protein and completed the immature stages in a shorter period than those reared on the other three plants. The relationship between head capsule width and larval instars on these four crops fitted well with Dyar's rule, and the Dyar's ratios ranged from 1.4554 to 1.6786, although a few supernumerary instar individuals on sesbania, peanut, and taro showed lower ratios (1.0103 to 1.1330). The head capsule width among cohorts fed on different host plants varied significantly and overlapped between late instars, which could lead to a misjudgment of instar stage in the field. The growth index of S. litura on cabbage was significantly higher than on the other host plants. Larvae fed on sesbania showed the highest feeding index and a better growth index than on taro and peanut. We therefore suggest that the area-wide pest management against S. litura should take into consideration its occurrence on sesbania in intercropping seasons. Additionally, the effective management of this pest during cropping windows between all these four plants should not be ignored. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Effects of temperature on Anoplophora glabripennis (Coleoptera: Cerambycidae) larvae and pupae
M.A. Keena; P.M. Moore
2010-01-01
Developmental thresholds, degree-days for development, larval weights, and head capsule widths for each larval instar and the pupal stage of Anoplophora glabripennis (Motschulsky) (Coleoptera: Cerambycidae) were studied at eight constant temperatures (5, 10, 15, 20, 25, 30, 35, and 40ºC) for two source populations (Ravenswood, Chicago, IL [...
Cuezzo, Carolina
2016-12-09
Coendutermes Fontes, 1985 is a monotypic South American termite genus. Coendutermes tucum Fontes, 1985, was described based on morphological characters from soldiers and workers collected in Mato Grosso, Brazil, and Jodensavanne, Suriname. Herein, I describe the imago caste of C. tucum for the first time with additional notes on soldiers, workers, and new distributional records. The studied material is deposited at the Museu de Zoologia da Universidade de São Paulo, São Paulo, Brazil (MZUSP). I use the terminology of Fontes (1987) to describe worker mandibles, and that of Noirot (2001) for the different parts of the digestive tube of workers. I measured the imagoes morphometric characters following Roonwal (1970): LH, length of head capsule (9); WH, width of head capsule without eyes (18); OF, occipito-fontanelle distance (23); DE, diameter of eye (48); LO, length of ocellus (55); WO, width of ocellus (56); EOD, eye-ocellus distance (57); LP, length of pronotum (65); WP, width of pronotum (68); LT, length of hind tibia (85). I took photographs of all castes with a stereomicroscope (Leica M205C) attached to a video camera (Leica DFC295) and images of gizzard and enteric valve under a microscope (Leica DM750B) attached to a video camera (Leica ICC50HD), then I combined the stacks of images with the software Leica LAS EZ 2.0 or Helicon Focus 5.2.11 X64. For the scanning electron micrographs (SEM), one soldier was dried to critical point while directly mounted on a stub with double face adhesive tape, then coated with gold and photographed with the SEM (Zeiss LEO 440 ®).
Head or tail: the orientation of the small bowel capsule endoscope movement in the small bowel.
Kopylov, Uri; Papageorgiou, Neofytos P; Nadler, Moshe; Eliakim, Rami; Ben-Horin, Shomron
2012-03-01
The diagnostic accuracy of capsule endoscopy has been suggested to be influenced by the direction of the passage in the intestine. It is currently unknown if a head-first or a tail-first orientation are equally common during the descent through the small bowel. The aim of the study was to identify the orientation of the capsule along the migration through the small bowel. Thirty capsule endoscopies were reviewed by an experienced observer. The direction of the passage through the pylorus and the ileoceccal valve was recorded for all the examinations. In addition, detailed review of the passage of the capsule in different segments of the small bowel was undertaken for all the capsules. The capsule was significantly more likely to pass the pylorus head-first compared to tail-first (25 and 5 out of 30, respectively, OR 5, 95% CI 65-94%, P < 0.001). In 28/30 studies, the capsule exited the ileoceccal valve head-first (OR-14, 95% CI 77-99%, P < 0.001). In an immersion experiment, uneven distribution of weight of the capsule body was demonstrated with the head part (camera tip) being lighter than the tail part. The capsule endoscope usually passes through the pylorus and subsequent segments of the small bowel head-first. This observation suggests that the intestinal peristaltic physiology drives symmetrical bodies with their light part first. The principle of intestinal orientation by weight distribution may bear implications for capsules' design in the future.
Competition among gene regulatory networks imposes order within the eye-antennal disc of Drosophila
Weasner, Bonnie M.; Kumar, Justin P.
2013-01-01
The eye-antennal disc of Drosophila gives rise to numerous adult tissues, including the compound eyes, ocelli, antennae, maxillary palps and surrounding head capsule. The fate of each tissue is governed by the activity of unique gene regulatory networks (GRNs). The fate of the eye, for example, is controlled by a set of fourteen interlocking genes called the retinal determination (RD) network. Mutations within network members lead to replacement of the eyes with head capsule. Several studies have suggested that in these instances all retinal progenitor and precursor cells are eliminated via apoptosis and as a result the surrounding head capsule proliferates to compensate for retinal tissue loss. This model implies that the sole responsibility of the RD network is to promote the fate of the eye. We have re-analyzed eyes absent mutant discs and propose an alternative model. Our data suggests that in addition to promoting an eye fate the RD network simultaneously functions to actively repress GRNs that are responsible for directing antennal and head capsule fates. Compromising the RD network leads to the inappropriate expression of several head capsule selector genes such as cut, Lim1 and wingless. Instead of undergoing apoptosis, a population of mutant retinal progenitors and precursor cells adopt a head capsule fate. This transformation is accompanied by an adjustment of cell proliferation rates such that just enough head capsule is generated to produce an intact adult head. We propose that GRNs simultaneously promote primary fates, inhibit alternative fates and establish cell proliferation states. PMID:23222441
Faria, Mafalda S; Lopes, Ricardo J; Nogueira, António J A; Soares, Amadeu M V M
2007-09-01
We used bioassays employing head capsule width and body length increase of Chironomus riparius larvae as end points to evaluate metal contamination in streams. Bioassays were performed in situ near an abandoned Portuguese goldmine in the spring of 2003 and 2004. Bioassays also were performed under laboratory conditions with water and sediment collected from each stream to verify if laboratory bioassays could detect in situ toxicity and to evaluate the relative contribution of sediment and water to overall toxicity. We used field sediments with control water and control sediments with field water to discriminate between metal contamination in water and sediment. Field water with dry and sieved, organic matter-free, and nontreated sediments was used to determine the toxicity of heavy metals that enter the organism through ingested material. In both in situ and laboratory bioassays, body length increase was significantly inhibited by metal contamination, whereas head capsule width was not affected. Body length increase was more affected by contaminated sediment compared to contaminated water. The lowest-effect level of heavy metals was observed in the dry and sieved sediment that prevented ingestion of sediment particles by larvae. These results suggest that body length increase of C. riparius larvae can be used to indicate the impact of metal contamination in rivers. Chironomus riparius larvae are more affected by heavy metals that enter the organism through ingested sediment than by heavy metals dissolved in the water column. Nevertheless, several factors, such as the particle size and organic matter of sediment, must be taken into account.
Research study on neck injury lessening with active head restraint using human body FE model.
Kitagawa, Yuichi; Yasuki, Tsuyoshi; Hasegawa, Junji
2008-12-01
The objective of this study is to examine the effectiveness of the active head restraint system in reducing neck injury risk of car occupants in low-speed rear impacts. A human body FE model "THUMS" was used to simulate head and neck kinematics of the occupant and to evaluate loading to the neck. Joint capsule strain was calculated to predict neck injury risk as well as NIC. The validity of the model was confirmed comparing its mechanical responses to those in human subjects in the literatures. Seat FE models were also prepared representing one with a fixed head restraint and the other one with an active head restraint system. The active head restraint system was designed to move the head restraint forward and upward when the lower unit was lower unit was loaded by the pelvis. Rear impact simulations were performed assuming a triangular acceleration pulse at a delta-V of 25 km/h. The model reproduced similar head and neck motions to those measured in the human volunteer test, except for active muscular responses. The calculated joint capsule strain also showed a good match with those of PMHS tests in the literature. A rear-impact simulation was conducted using the model with the fixed head restraint. The result revealed that NIC was strongly correlated with the relative acceleration between the head and the torso and that its maximum peak appeared when the head contacted the head restraint. It was also found that joint capsule strain grew in later timing synchronizing with the relative displacement. Another simulation with the active head restraint system showed that both NIC and joint capsule strain were lowered owing to the forward and upward motion of the head restraint. A close investigation of the vertebral motion indicated that the active head restraint reduced the magnitude of shear deformation in the facet joint, which contributed to the strain growth in the fixed head restraint case. Rear-impact simulations were conducted using a human body FE model, THUMS, representing an average-size male occupant. The cervical system including the facet joint capsules was incorporated to the model. The validity of the model was examined comparing its mechanical responses to those in the literature such as the whole body motion of the volunteer subject and the vertebral motion in the PMHS tests. Rear-impact simulations were conducted using the validated THUMS model and two prototype seat models; one had a fixed head restraint and the other one was equipped with an active head restraint system. The active head restraint system works moving the head restraint forward and upward when the lower unit is loaded by the pelvis. The head and neck kinematics and responses were analyzed from the simulation results. The force and acceleration rose at the pelvis first, followed by T1 and the head. The early timing of force rise and its magnitude indicated that the pelvis force was a good trigger for the active head restraint system. The results showed that the head was supported earlier in a case with the active head restraint system, and both NIC and joint capsule strain were lowered. The study also analyzed the mechanism of strain growth in the joint capsules. Relatively greater strain was observed in the direction of the facet joint surface, which was around 45 degrees inclined to the spinal column. The forward and upward motion of the active head restraint were aligned with the direction of the joint deformation and contributed to lower strain in the joint capsules. The results indicated that the active head restraint could help reduce the neck injury risk not only by supporting the head at an early timing but also through its trajectory stopping the joint deformation.
Convergent evolution of sexual shape dimorphism in Diptera.
Bonduriansky, Russell
2006-05-01
Several patterns of sexual shape dimorphism, such as male body elongation, eye stalks, or extensions of the exoskeleton, have evolved repeatedly in the true flies (Diptera). Although these dimorphisms may have evolved in response to sexual selection on male body shape, conserved genetic factors may have contributed to this convergent evolution, resulting in stronger phenotypic convergence than might be expected from functional requirements alone. I compared phenotypic variation in body shape in two distantly related species exhibiting sexually dimorphic body elongation: Prochyliza xanthostoma (Piophilidae) and Telostylinus angusticollis (Neriidae). Although sexual selection appears to act differently on male body shape in these species, they exhibited strikingly similar patterns of sexual dimorphism. Likewise, patterns of within-sex shape variation were similar in the two species, particularly in males: relative elongation of the male head capsule, antenna, and legs was associated with reduced head capsule width and wing length, but was nearly independent of variation in thorax length. However, the two species presented contrasting patterns of static allometry: male sexual traits exhibited elevated allometric slopes in T. angusticollis, but not in P. xanthostoma. These results suggest that a shared pattern of covariation among traits may have channeled the evolution of sexually dimorphic body elongation in these species. Nonetheless, static allometries may have been shaped by species-specific selection pressures or genetic architectures. Copyright 2006 Wiley-Liss, Inc.
Posnien, Nico; Bucher, Gregor
2010-02-01
The insect head is composed of several segments. During embryonic development, the segments fuse to form a rigid head capsule where obvious segmental boundaries are lacking. Hence, the assignment of regions of the insect head to specific segments is hampered, especially with respect to dorsal (vertex) and lateral (gena) parts. We show that upon Tribolium labial (Tc-lab) knock down, the intercalary segment is deleted but not transformed. Furthermore, we find that the intercalary segment contributes to lateral parts of the head cuticle in Tribolium. Based on several additional mutant and RNAi phenotypes that interfere with gnathal segment development, we show that these segments do not contribute to the dorsal head capsule apart from the dorsal ridge. Opposing the classical view but in line with findings in the vinegar fly Drosophila melanogaster and the milkweed bug Oncopeltus fasciatus, we propose a "bend and zipper" model for insect head capsule formation.
NASA Astrophysics Data System (ADS)
van Hardenbroek, M.; Heiri, O. M.; Grey, J.; Bodelier, P. L. E.; Lotter, A. F.
2009-04-01
Lake sediments are an important source of atmospheric methane. Methanogenic archaea in lake sediments produce 13C-depleted methane that is partly released to the water column and the atmosphere. Another part is utilized by methane oxidizing bacteria (MOB) that are an important food source for deposit-feeding chironomid larvae (Diptera: Chironomidae). If methane-derived carbon is a significant component of the chironomid diet this will lead to strongly negative d13C in the tissue and exoskeleton of chironomid larvae. Chironomid cuticles, especially the strongly sclerotized head capsules, are well preserved as fossils in lake sediments. If the relationship between modern methane fluxes in lakes and chironomid d13C can be established this would therefore provide an approach for estimating past methane fluxes based on d13C of fossil chironomid remains. Using culturing experiments we show that the stable carbon isotope signature of MOB and other food sources can be traced in chironomid muscle tissue as well as in the fossilizing exoskeleton. In addition we measured d13C in chironomid larval head capsules and other invertebrate remains from a range of surface and downcore sediment samples. Small intra-specific variability (-27.1 ± 0.08 permille) was measured in replicate samples of chironomid head capsules of Corynocera ambigua (n=7). d13C of chironomid head capsules from a several different taxa ranged from -28.0 to -25.8 permille, but in some instances we observed d13C values as low as -36.9 to -31.5 permille, suggesting that carbon from MOB can be successfully traced in fossil and subfossil chironomid remains. Our results demonstrate that the stable carbon isotope signature of MOB is incorporated into chironomid head capsules. Future research will focus on quantifying the relationship between methane fluxes, MOB, and head capsule d13C in order to reconstruct past methane fluxes based on the lake sediment record.
NASA Astrophysics Data System (ADS)
Zhao, Y.; Nelson, D. M.; Clegg, B. F.; Berry, J.; Hu, F.
2016-12-01
δ13C analysis of specific taxa or compounds is commonly used for investigating past environmental change, including methane dynamics in lakes. However, most analytical methods require large sample sizes, prohibiting routine analysis of fossils of individual taxa found in sediment deposits. For example, 10-100 individual head capsules of fossil midges are required for δ13C analysis using an elemental analyzer (EA) interfaced with an isotope-ratio mass spectrometer (IRMS). Here we present a new method that uses a spooling-wire microcombustion (SWiM) device interfaced with an IRMS for measuring δ13C values of carbon dissolved from individual head capsules of chitinous aquatic zooplankton. We extracted chitin (a major biochemical component of insect exoskeleton) from modern midge material obtained from four commercial suppliers. We first assessed the effects of sample treatments on carbon yields and δ13C values of dissolved chitin by varying the concentration of HCl used for dissolution, the duration of reaction in HCl, and the temperature of dissolution. We then investigated potential fractionation of carbon isotopes associated with chitin dissolution, by comparing δ13C values of dissolved chitin obtained via SWiM-IRMS with those from untreated head capsules obtained via a EA-IRMS. The average δ13C values of untreated head capsules varied between -25.1 and -30.1‰. Higher acid concentrations and temperatures, as well as longer reaction times, increased dissolution of carbon from the head capsules and the precision of δ13C values. For example, carbon yields from reaction of head capsules with 6N HCl at 25°C increased from 1 to 3 Vs as reaction times increased from 1 to 24 hours. Acid concentration and reaction time had the greatest influence on carbon yields and isotopic precision. The δ13C values of dissolved chitin mirrored the δ13C values of untreated head capsules with minimal offset of absolute values, which suggests no systematic fractionation associated with dissolution. Overall, these results indicate that carbon isotopic analysis of dissolved chitin using the SWiM-IRMS system offers a reliable new method to determine taxa-specific δ13C values for chitinous aquatic zooplankton. In ongoing work, we are applying this tool to reconstruct past methane dynamics in Arctic lakes during the Holocene.
Kitagawa, Yuichi; Yasuki, Tsuyoshi; Hasegawa, Junji
2006-11-01
Many efforts have been made to understand the mechanism of whiplash injury. Recently, the cervical facet joint capsules have been focused on as a potential site of injury. An experimental approach has been taken to analyze the vertebral motion and to estimate joint capsule stretch that was thought to be a potential cause of pain. The purpose of this study is to analyze the kinematics of the cervical facet joint using a human FE model in order to better understand the injury mechanism. The Total Human Model for Safety (THUMS) was used to visually analyze the local and global kinematics of the spine. Soft tissues in the neck were newly modeled and introduced into THUMS for estimating the loading level in rear impacts. The model was first validated against human test data in the literature by comparing vertebrae motion as well as head and neck responses. Joint capsule strain was estimated from a maximum principal strain output from the elements representing the capsule tissues. A rear-end collision was then simulated using THUMS and a prototype seat model, assuming a delta-V of 25 km/h. The trajectory of the vertebrae was analyzed in a local coordinate system defined along the joint surface. Strain growth in the joint capsules was explained, as related to contact events between the occupant and the seat. A new seat concept was proposed to help lessen the loading level to the neck soft tissues. The foam material of the seat back was softened, the initial gap behind the head was reduced and the head restraint was stiffened for firm support. The lower seat back frame was also reinforced to withstand the impact severity at the given delta-V. Another rear impact simulation was conducted using the new seat concept model to examine the effectiveness of the new concept. The joint capsule strain was found to be relatively lower with the new seat concept. The study also discusses the influence of seat parameters to the vertebral motion and the resultant strain in the joint capsules. The meaning of the contact timing of the head to the head restraint was examined based on the results in terms of correlation with injury indicators such as NIC and the joint capsule strain.
Maneechan, Witwisitpong; Kruttha, Phassawat; Prommi, Taeng On
2018-03-14
The immature and adult stages of Potamyia flavata Banks 1934 were sampled in seven sampling sites in streams of western Thailand. The samples were collected in February, May, and December 2015 using hand picking. A total of 2,133 individuals of larvae were collected. The larva and pupa of Po. flavata are described and illustrated. Larvae have five instars. The head capsule width of the first to the fifth instar larvae were 0.20-0.29, 0.30-0.39, 0.40-0.59, 0.60-0.79, and 0.80-1.15 mm, respectively. Gut content analysis revealed that larvae are omnivorous filterers. The guts of the larvae contained mainly diatoms and green algae followed by filamentous algae, detritus, and arthropod fragments.
Ou, Youkuan; Xiao, Enhua; Shang, Quanliang; Chen, Juan
2015-10-01
To investigate the imaging manifestations of CT, MRI and pathological basis for hepatic capsular retraction syndrome caused by benign and malignant liver tumors. CT or MRI images and pathological features for hepatic capsular retraction syndrome were retrospectively analyzed in 50 patients with benign and malignant liver tumors. Picture archive and communication system (PACS) was used to observe and compare the morphology, size, width, depth, edge of the capsular retraction and the status of liquid under the liver capsule. The structure, differentiation and proliferation of the tumor were analyzed under the microscope. There were malignant liver tumors in 44 patients and benign tumor in 6 patients. The smooth or rough for the edge of capsular retraction was significant difference between the benign tumors and the malignant tumors with three differentiated grades (all P<0.05). There were significant difference in the width and depth for capsule retraction with different amount of fibrous tissues (all P<0.05). The width and depth of capsule retraction were positively correlated to the size of the tumors (r=0.557, 0.309 respectively, both P<0.05). Benign and malignant hepatic tumors may appear capsule retraction syndrome, but there are morphological differences between them. The differences are closely related with the lesion size, differentiated degree of tumor and fibrous tissue proliferation.
Colon Capsule Endoscopy for the Detection of Colorectal Polyps: An Economic Analysis
Palimaka, Stefan; Blackhouse, Gord; Goeree, Ron
2015-01-01
Background Colorectal cancer is a leading cause of mortality and morbidity in Ontario. Most cases of colorectal cancer are preventable through early diagnosis and the removal of precancerous polyps. Colon capsule endoscopy is a non-invasive test for detecting colorectal polyps. Objectives The objectives of this analysis were to evaluate the cost-effectiveness and the impact on the Ontario health budget of implementing colon capsule endoscopy for detecting advanced colorectal polyps among adult patients who have been referred for computed tomographic (CT) colonography. Methods We performed an original cost-effectiveness analysis to assess the additional cost of CT colonography and colon capsule endoscopy resulting from misdiagnoses. We generated diagnostic accuracy data from a clinical evidence-based analysis (reported separately), and we developed a deterministic Markov model to estimate the additional long-term costs and life-years lost due to false-negative results. We then also performed a budget impact analysis using data from Ontario administrative sources. One-year costs were estimated for CT colonography and colon capsule endoscopy (replacing all CT colonography procedures, and replacing only those CT colonography procedures in patients with an incomplete colonoscopy within the previous year). We conducted this analysis from the payer perspective. Results Using the point estimates of diagnostic accuracy from the head-to-head study between colon capsule endoscopy and CT colonography, we found the additional cost of false-positive results for colon capsule endoscopy to be $0.41 per patient, while additional false-negatives for the CT colonography arm generated an added cost of $116 per patient, with 0.0096 life-years lost per patient due to cancer. This results in an additional cost of $26,750 per life-year gained for colon capsule endoscopy compared with CT colonography. The total 1-year cost to replace all CT colonography procedures with colon capsule endoscopy in Ontario is about $2.72 million; replacing only those CT colonography procedures in patients with an incomplete colonoscopy in the previous year would cost about $740,600 in the first year. Limitations The difference in accuracy between colon capsule endoscopy and CT colonography was not statistically significant for the detection of advanced adenomas (≥ 10 mm in diameter), according to the head-to-head clinical study from which the diagnostic accuracy was taken. This leads to uncertainty in the economic analysis, with results highly sensitive to changes in diagnostic accuracy. Conclusions The cost-effectiveness of colon capsule endoscopy for use in patients referred for CT colonography is $26,750 per life-year, assuming an increased sensitivity of colon capsule endoscopy. Replacement of CT colonography with colon capsule endoscopy is associated with moderate costs to the health care system. PMID:26366240
Syaukani, Syaukani; Thompson, Graham J; Zettel, Herbert; Pribadi, Teguh
2016-01-01
A new species of open-air processional column termite is here described based on the soldier and worker castes from eight colonies in north Barito, central Kalimantan. Hospitalitermes nigriantennalis sp. n. is readily distinguished in the field from related Hospitalitermes spp. by the light brown to orangish coloration of the soldier head capsule that, further, is with vertex yellowish and nasus brownish. The soldier antenna and the maxillary and labial palps are blackish. By contrast, soldiers from other species of Hospitalitermes from this region have a uniformly black head capsule and antennae. Finally, Hospitalitermes nigriantennalis sp. n. has a minute indentation in the middle of the posterior part of head capsule, which further helps to differentiate this new species from other Hospitalitermes from the Indo-Malayan and Austro-Malayan regions.
Syaukani, Syaukani; Thompson, Graham J.; Zettel, Herbert; Pribadi, Teguh
2016-01-01
Abstract A new species of open-air processional column termite is here described based on the soldier and worker castes from eight colonies in north Barito, central Kalimantan. Hospitalitermes nigriantennalis sp. n. is readily distinguished in the field from related Hospitalitermes spp. by the light brown to orangish coloration of the soldier head capsule that, further, is with vertex yellowish and nasus brownish. The soldier antenna and the maxillary and labial palps are blackish. By contrast, soldiers from other species of Hospitalitermes from this region have a uniformly black head capsule and antennae. Finally, Hospitalitermes nigriantennalis sp. n. has a minute indentation in the middle of the posterior part of head capsule, which further helps to differentiate this new species from other Hospitalitermes from the Indo-Malayan and Austro-Malayan regions. PMID:26877678
Capsule endoscopy: no longer limited to the small bowel.
Niv, Yaron
2010-03-01
Capsule endoscopy is the latest evolution in gastrointestinal endoscopy and the first to enable complete investigation of the small bowel. Recent new developments in the field of capsule endoscopy include the esophageal capsule (Pilcam ESO) and the colonic capsule (PillCam Colon). esophageal and colonic capsules have two heads with two lenses and cameras. The new capsules have the capability of taking more frames from both sides. The indications for the esophageal capsule examination are diagnosis and follow-up of Barrett's esophagus and esophageal varices. The colonic capsule can be used for colorectal cancer screening and for incomplete colonoscopy. Regarding other new technologies, continuous quality control is needed for the performance, appropriateness of the indications, diagnostic yield, procedure-specific outcome assessment, and cost-effectiveness.
Mihata, Teruhisa; McGarry, Michelle H; Kahn, Timothy; Goldberg, Iliya; Neo, Masashi; Lee, Thay Q
2016-01-01
Acromioplasty is increasingly being performed for both reparable and irreparable rotator cuff tears. However, acromioplasty may destroy the coracoacromial arch, including the coracoacromial ligament, consequently causing a deterioration in superior stability even after superior capsule reconstruction. The purpose of this study was to investigate the effects of acromioplasty on shoulder biomechanics after superior capsule reconstruction for irreparable supraspinatus tendon tears. The hypothesis was that acromioplasty with superior capsule reconstruction would decrease the area of subacromial impingement without increasing superior translation and subacromial contact pressure. Controlled laboratory study. Seven fresh-frozen cadaveric shoulders were evaluated using a custom shoulder testing system. Glenohumeral superior translation, the location of the humeral head relative to the glenoid, and subacromial contact pressure and area were compared among 4 conditions: (1) intact shoulder, (2) irreparable supraspinatus tendon tear, (3) superior capsule reconstruction without acromioplasty, and (4) superior capsule reconstruction with acromioplasty. Superior capsule reconstruction was performed using the fascia lata. Compared with the intact shoulder, the creation of an irreparable supraspinatus tear significantly shifted the humeral head superiorly in the balanced muscle loading condition (without superior force applied) (0° of abduction: 2.8-mm superior shift [P = .0005]; 30° of abduction: 1.9-mm superior shift [P = .003]) and increased both superior translation (0° of abduction: 239% of intact [P = .04]; 30° of abduction: 199% of intact [P = .02]) and subacromial peak contact pressure (0° of abduction: 308% of intact [P = .0002]; 30° of abduction: 252% of intact [P = .001]) by applying superior force. Superior capsule reconstruction without acromioplasty significantly decreased superior translation (0° of abduction: 86% of intact [P = .02]; 30° of abduction: 75% of intact [P = .002]) and subacromial peak contact pressure (0° of abduction: 47% of intact [P = .0002]; 30° of abduction: 83% of intact [P = .0005]; 60° of abduction: 38% of intact [P = .04]) compared with after the creation of a supraspinatus tear. Adding acromioplasty significantly decreased the subacromial contact area compared with superior capsule reconstruction without acromioplasty (0° of abduction: 26% decrease [P = .01]; 30° of abduction: 21% decrease [P = .009]; 60° of abduction: 61% decrease [P = .003]) and did not alter humeral head position, superior translation, or subacromial peak contact pressure. Superior capsule reconstruction repositioned the superiorly migrated humeral head and restored superior stability in the shoulder joint. Adding acromioplasty decreased the subacromial contact area without increasing the subacromial contact pressure. When superior capsule reconstruction is performed for irreparable rotator cuff tears, acromioplasty may help to decrease the postoperative risk of abrasion and tearing of the graft beneath the acromion. © 2015 The Author(s).
Small queens and big-headed workers in a monomorphic ponerine ant
NASA Astrophysics Data System (ADS)
Kikuchi, Tomonori; Miyazaki, Satoshi; Ohnishi, Hitoshi; Takahashi, Junichi; Nakajima, Yumiko; Tsuji, Kazuki
2008-10-01
Evolution of caste is a central issue in the biology of social insects. Comparative studies on their morphology so far suggest the following three patterns: (1) a positive correlation between queen worker size dimorphism and the divergence in reproductive ability between castes, (2) a negative correlation among workers between morphological diversity and reproductive ability, and (3) a positive correlation between queen worker body shape difference and the diversity in worker morphology. We conducted morphological comparisons between castes in Pachycondyla luteipes, workers of which are monomorphic and lack their reproductive ability. Although the size distribution broadly overlapped, mean head width, head length, and scape length were significantly different between queens and workers. Conversely, in eye length, petiole width, and Weber’s length, the size differences were reversed. The allometries (head length/head width, scape length/head width, and Weber’s length/head width) were also significantly different between queens and workers. Morphological examinations showed that the body shape was different between queens and workers, and the head part of workers was disproportionately larger than that of queens. This pattern of queen worker dimorphism is novel in ants with monomorphic workers and a clear exception to the last pattern. This study suggests that it is possible that the loss of individual-level selection, the lack of reproductive ability, influences morphological modification in ants.
Head capsule characters in the Hymenoptera and their phylogenetic implications
Vilhelmsen, Lars
2011-01-01
Abstract The head capsule of a taxon sample of three outgroup and 86 ingroup taxa is examined for characters of possible phylogenetic significance within Hymenoptera. 21 morphological characters are illustrated and scored, and their character evolution explored by mapping them onto a phylogeny recently produced from a large morphological data set. Many of the characters are informative and display unambiguous changes. Most of the character support demonstrated is supportive at the superfamily or family level. In contrast, only few characters corroborate deeper nodes in the phylogeny of Hymenoptera. PMID:22259288
Nimura, Akimoto; Fujishiro, Hitomi; Wakabayashi, Yoshiaki; Imatani, Junya; Sugaya, Hiroyuki; Akita, Keiichi
2014-02-01
To identify the unique anatomical characteristic of the extensor carpi radialis brevis (ECRB) origin and points of differentiation from other extensors and to clarify the specific relationship of the ECRB to the underlying structures. We studied the origin of each extensor macroscopically for its muscular and tendinous parts; to identify the relationship between the ECRB origin and the deeper structures, we also examined the attachment of the joint capsule under the ECRB origin. The ECRB simply originated as a tendon without any muscle, whereas other extensors originated as a mixture of tendon and muscle. At the anterior part of the ECRB origin, the thin attachment of the joint capsule (average width, 3.3 mm) lay deep to the ECRB and was distinct. However, at the posterodistal portion, the joint capsule, annular ligament, and supinator were intermingled and originated as a single wide sheet from the humerus (average width, 10.7 mm). The anterior part of the ECRB origin was delicate, because the ECRB origin was purely tendinous, and the attachment of the articular capsule was thin compared with that of the posterodistal attachment. This thin attachment could be an initial factor leading to the development of lateral epicondylitis. The results of the current study may enhance magnetic resonance imaging understanding and may help clarify the etiology of the lateral epicondylitis. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
[Measurement and analysis of human head-face dimensions].
DU, Li-Li; Wang, Li-Min; Zhuang, Ziqing
2008-05-01
To probe into the physical changes on the head and face of Chinese adults, find the representative indexes and provide references for head-face products design especially in the field of labor protection. The ISO7250-1996 and GB/T5703-99 Basic Human Body Measurements for Technological Design was used. Twenty items of head-face referential parameters and 4 items of body indexes (height, weight, waist circumference and buttock circumference) were measured by using sliding caliper, spreading caliper and pupillometer. The populations were sampled by age, gender and region and their influences on the head and face dimensions were statistically analyzed. By studying the relationship between these parameters with correlation and cluster analysis, the representative indexes of head and face dimensions were concluded. 3000 objectives (2026 men and 974 women) were involved in this survey. The results enunciated that the values of the items in male were larger than those in female. For example, the mean values of face length, face width, jaw width, lip length and nose protrusion were 117.0, 147.6, 118.5, 51.7, 18.7 mm for male and 109.7, 140.1, 114.5, 49.3, 17.7 mm for female. The regional disparity and obesity were significant factors. The sizes of head and face of north-eastern population were significantly bigger than those of south-western population except of maximum length of head, the length of lip and face configuration length. The sizes of head and face of obesity population were significantly bigger than those of non-obesity population (P < 0.01). By the cluster analysis, five representative indexes (face length, face width, jaw width, lip length and nose protrusion) were obtained. Further correction analysis suggested that these indexes could well represent the head-face dimensions. The influence of gender, region and obesity on the head-face dimensions is significant. The age is not a significant influential factor. Five representative indexes (face length, face width, jaw width, lip length and nose protrusion) are obtained to provide foundation in the standard design of head-face products.
Liang, Junkui; Jiang, Xiliang; Zhang, Xiulin; Cao, Wendong; Wang, Yong; Han, Jie
2015-11-01
The objective of this study was to investigate the effectiveness of interventional catheterization with staphylococcin aureus injection on ischemic necrosis of the femoral heads. By percutaneous catheterization of the femoral artery, papaverine, urokinase, compound Danshen, and anisodamine were injected intravenously into the arteries of the femoral head. Staphylococcin aureus injection was injected into the hit joint capsule on the side of the lesion to compare the conditions before and after surgery. The patients did the rehabilitation exercises of the hit joint 48 h after the surgery and had double crutches for 3-6 months. Of the 112 cases, 39 cases (34.8 %) were cured, 51 cases (45.6 %) were markedly effective, and 22 cases (19.6 %) were effective. Interventional catheterization combined with staphylococcin aureus injection given into the hit joint capsule is an effective way to treat ischemic necrosis of the femoral head by influencing the internal and external environments of the femoral head.
Baum, Eileen; Hertel, Wieland; Beutel, Rolf Georg
2007-01-01
The head capsule, the circulatory system and the central nervous system of the head of Prosarthria teretrirostris (Proscopiidae) is described in detail, with special consideration of modifications resulting from the aberrant head shape. The transformations of the head are completely different from those found in phasmatodeans, which are also characterised by twig mimesis. The circulatory system is distinctly modified. A hitherto undescribed additional structure in the posterior head region very likely functions as a pulsatile organ. The cephalic central nervous system is strongly elongated, with changes in the position of the suboesophageal ganglion, the corpora cardiaca and the course of the nervus mandibularis. Three-dimensional reconstructions of these two organ systems in combination with the pharynx were made using Alias Maya 6.0 software. Comparisons with other representatives of Caelifera suggest a clade comprising Proscopiidae and Morabinae. The presence of a transverse muscle connecting the antennal ampullae in Prosarthria shows that this structure likely belongs to the groundplan of Orthoptera, even though it is missing in different representatives of this group. The transverse ampullary muscle is a potential synapomorphy of Orthoptera, Phasmatodea and Dictyoptera.
Tineshev, Slavi At
2010-01-01
It is impossible to give an objective anthropologic assessment of the overall physical development of a child's body during the time of intensive growth (7-17 years) without taking into account the age and gender changes in the absolute and relative head and face measurements. Head growth has specific characteristics that makes it different from the growth of other parts of the body. The head of a child differs from the head of an adult not only by metric characteristics but also by the proportions between the different head measurements. Growth and proportionality of the head comply with the general growth pattern, but there are also certain regional, populational and temporal differences. That was the reason why we conducted a study targeted at children and adolescents from the region of the Eastern Rhodopes. The aim Of the present study was to determine the growth dynamics in between-gender and between-age aspects of the variables characterizing the neurocranium and facial cranium, and establish the tendency and direction of the secular changes, The study included 1481 children and adolescents (699 boys and 782 girls) aged 7 to 17 years that were examined using the classical methodology of Martin-Saller (1957). Head length, width, height and circumference, as well as face width, mandible width, morphological and physiognomic height of the face were measured. Head index, morphological face index and jugulormandibular index were calculated using standard formulas. The secular changes were analyzed comparing data from 1907 and 1960 with the data of the present study. The head index classified the children from both genders and all age groups as mesocephals. The girls from the study region had a relatively greater mandible width and boys - relatively greater face width. In the beginning of the growth period wider face forms prevailed especially in the girls, while narrower face forms were more characteristic for the adolescence and postadolescence and better manifested in the boys. Throughout the entire study period the boys presented with greater measurements of the neurocranium and facial cranium than the girls. For both genders the increase in the neurocranium measurements anticipates that in the facial cranium measurements. In the examined children and adolescents the width cephalometric variables complete their growth earlier than the height variables. The head circumference and head width decrease, while the differences in the head length and facial height increase in both genders and all age groups in the end of the 20th and beginning of the 21st century.
Recent results of the Defect-Induced Mix Experiments (DIME) on NIF
NASA Astrophysics Data System (ADS)
Schmitt, M. J.; Bradley, P. A.; Cobble, J. A.; Hakel, P.; Hsu, S. C.; Krasheninnikova, N. S.; Kyrala, G. A.; Murphy, T. J.; Obrey, K. A.; Shah, R. C.; Tregillis, I. L.; Craxton, S. C.; McKenty, P. W.; Mancini, R. C.; Johns, H. M.; Joshi, Tirtha; Mayes, Daniel
2012-10-01
Investigations of directly driven implosions have been performed including experiments on Omega, and more recently NIF, to deduce the extent and uniformity of 4π and defect-induced mix near the shell/gas interface of plastic (CH) capsules filled with 5 atm D2 gas. Imaging diagnostics are used to measure the spatial variation of mix caused by the growth of non-uniformities in both capsule and laser drive characteristics. Thin (2μm) layers containing 1-2% (atomic) mid-Z dopants are imaged spectrally at late time in the implosion using multiple monochromatic imaging of H-like and He-like atomic line emission. Areal image backlighting of the capsules provides both r(t) and the symmetry of the implosion. Recent results will be shown including inferred 4π mix width, laser imprint induced mix, and mix from capsule variations.
Arefin, Md Shamsul; Redoute, Jean-Michel; Yuce, Mehmet Rasit
2018-01-01
This paper presents a wireless capsule microsystem to detect and monitor the pH, pressure, and temperature of the gastrointestinal tract in real time. This research contributes to the integration of sensors (microfabricated capacitive pH, capacitive pressure, and resistive temperature sensors), frequency modulation and pulse width modulation based interface IC circuits, microcontroller, and transceiver with meandered conformal antenna for the development of a capsule system. The challenges associated with the system miniaturization, higher sensitivity and resolution of sensors, and lower power consumption of interface circuits are addressed. The layout, PCB design, and packaging of a miniaturized wireless capsule, having diameter of 13 mm and length of 28 mm, have successfully been implemented. A data receiver and recorder system is also designed to receive physiological data from the wireless capsule and to send it to a computer for real-time display and recording. Experiments are performed in vitro using a stomach model and minced pork as tissue simulating material. The real-time measurements also validate the suitability of sensors, interface circuits, and meandered antenna for wireless capsule applications.
Fencl, Jane S.; Mather, Martha E.; Costigan, Katie H.; Daniels, Melinda D.
2015-01-01
Longitudinal connectivity is a fundamental characteristic of rivers that can be disrupted by natural and anthropogenic processes. Dams are significant disruptions to streams. Over 2,000,000 low-head dams (<7.6 m high) fragment United States rivers. Despite potential adverse impacts of these ubiquitous disturbances, the spatial impacts of low-head dams on geomorphology and ecology are largely untested. Progress for research and conservation is impaired by not knowing the magnitude of low-head dam impacts. Based on the geomorphic literature, we refined a methodology that allowed us to quantify the spatial extent of low-head dam impacts (herein dam footprint), assessed variation in dam footprints across low-head dams within a river network, and identified select aspects of the context of this variation. Wetted width, depth, and substrate size distributions upstream and downstream of six low-head dams within the Upper Neosho River, Kansas, United States of America were measured. Total dam footprints averaged 7.9 km (3.0–15.3 km) or 287 wetted widths (136–437 wetted widths). Estimates included both upstream (mean: 6.7 km or 243 wetted widths) and downstream footprints (mean: 1.2 km or 44 wetted widths). Altogether the six low-head dams impacted 47.3 km (about 17%) of the mainstem in the river network. Despite differences in age, size, location, and primary function, the sizes of geomorphic footprints of individual low-head dams in the Upper Neosho river network were relatively similar. The number of upstream dams and distance to upstream dams, but not dam height, affected the spatial extent of dam footprints. In summary, ubiquitous low-head dams individually and cumulatively altered lotic ecosystems. Both characteristics of individual dams and the context of neighboring dams affected low-head dam impacts within the river network. For these reasons, low-head dams require a different, more integrative, approach for research and management than the individualistic approach that has been applied to larger dams.
Costigan, Katie H.; Daniels, Melinda D.
2015-01-01
Longitudinal connectivity is a fundamental characteristic of rivers that can be disrupted by natural and anthropogenic processes. Dams are significant disruptions to streams. Over 2,000,000 low-head dams (<7.6 m high) fragment United States rivers. Despite potential adverse impacts of these ubiquitous disturbances, the spatial impacts of low-head dams on geomorphology and ecology are largely untested. Progress for research and conservation is impaired by not knowing the magnitude of low-head dam impacts. Based on the geomorphic literature, we refined a methodology that allowed us to quantify the spatial extent of low-head dam impacts (herein dam footprint), assessed variation in dam footprints across low-head dams within a river network, and identified select aspects of the context of this variation. Wetted width, depth, and substrate size distributions upstream and downstream of six low-head dams within the Upper Neosho River, Kansas, United States of America were measured. Total dam footprints averaged 7.9 km (3.0–15.3 km) or 287 wetted widths (136–437 wetted widths). Estimates included both upstream (mean: 6.7 km or 243 wetted widths) and downstream footprints (mean: 1.2 km or 44 wetted widths). Altogether the six low-head dams impacted 47.3 km (about 17%) of the mainstem in the river network. Despite differences in age, size, location, and primary function, the sizes of geomorphic footprints of individual low-head dams in the Upper Neosho river network were relatively similar. The number of upstream dams and distance to upstream dams, but not dam height, affected the spatial extent of dam footprints. In summary, ubiquitous low-head dams individually and cumulatively altered lotic ecosystems. Both characteristics of individual dams and the context of neighboring dams affected low-head dam impacts within the river network. For these reasons, low-head dams require a different, more integrative, approach for research and management than the individualistic approach that has been applied to larger dams. PMID:26540105
1986-05-01
measurements were of an anatomical region rather than a specific bone. Measurements were made of head width, head length, shoulder width, hip width...the4 elbows behind its back. It was also necessary to palpate the bone to be sure that the measuring points were over the bony surface and not on the...11Z surrounding musculature. Hip width was measured with the ends of the open calipers on the two points of the greater trochanter. It was observed
Park, Choul Yong; Marando, Catherine M; Liao, Jason A; Lee, Jimmy K; Kwon, Jiwon; Chuck, Roy S
2016-10-01
To investigate the architecture and distribution of collagen and elastin in human limbal conjunctiva, Tenon's capsule, and sclera. The limbal conjunctiva, Tenon's capsule, and sclera of human donor corneal buttons were imaged with an inverted two-photon excited fluorescence microscope. No fixation process was necessary. The laser (Ti:sapphire) was tuned at 850 nm for two-photon excitation. Backscatter signals of second harmonic generation (SHG) and autofluorescence (AF) were collected through a 425/30-nm and a 525/45-nm emission filter, respectively. Multiple, consecutive, and overlapping (z-stack) images were acquired. Collagen signals were collected with SHG, whereas elastin signals were collected with AF. The size and density of collagen bundles varied widely depending on depth: increasing from conjunctiva to sclera. In superficial image planes, collagen bundles were <10 μm in width, in a loose, disorganized arrangement. In deeper image planes (episclera and superficial sclera), collagen bundles were thicker (near 100 μm in width) and densely packed. Comparatively, elastin fibers were thinner and sparse. The orientation of elastin fibers was independent of collagen fibers in superficial layers; but in deep sclera, elastin fibers wove through collagen interbundle gaps. At the limbus, both collagen and elastin fibers were relatively compact and were distributed perpendicular to the limbal annulus. Two-photon excited fluorescence microscopy has enabled us to understand in greater detail the collagen and elastin architecture of the human limbal conjunctiva, Tenon's capsule, and sclera.
Craniofacial morphologic parameters in a Persian population: an anthropometric study.
Amini, Fariborz; Mashayekhi, Ziba; Rahimi, Hajir; Morad, Golnaz
2014-09-01
Limited data are available regarding the reference ranges of facial proportions of the Persian population in Iran. This study aimed to establish the reference range of craniofacial anthropometric measurements in an adult Iranian population. On 100 individuals (men = women), aged 18 to 30 years with normal faces and occlusions, 34 linear and 7 angular measurements as well as 24 indices were calculated. The difference of measurements between men and women were evaluated by paired t-test. The data were compared with the norms of North American whites using 1-sample t-test. The subjects belonged to 5 ethnic groups (57% from Fars, 14% from Kord, 11% from Azari, 10% from Gilaki-Mazani, and 2% from Lor). All head measurements were greater in men except for the head index and the head height. The subjects had leptoprosopic faces. The intercanthal width was almost one third of the biocular width and greater than the eye fissure length. Although the nose width of women was significantly smaller, both sexes had leptorrhine noses. The chin height and lower chin height were greater in men. In comparison with North American whites, considerable differences were found regarding head height and width, biocular width, nose height, face height, mouth width, and upper chin height. In conclusion, the reference range of craniofacial anthropometric measurements established for the Iranian population might be efficiently used for esthetic treatments.
Simulations of 2-shock Convergence Scan Shots
NASA Astrophysics Data System (ADS)
Bradley, Paul; Olson, R. E.; Kline, J. L.; MacLaren, S. A.; Ma, T.; Salmonson, J. D.; Kyrala, G. A.; Pino, J.; Dewald, E.; Khan, S.; Sayre, D.; Ralph, J.; Turnbull, D.
2016-10-01
The 2-shock campaign is a joint Los Alamos/Livermore project to investigate the role of shock timing, asymmetry, and shock convergence on the performance of ignition relevant capsules. This campaign uses a simple two step pulse that makes it easier to correlate the effect of changing the laser pulse on the performance of the capsule. The 680 micron outer radius capsule has a CH +1 at% Si ablator approximately 175 microns thick surrounding a DD or HT gas region with fill densities between 0.0085 and 0.00094 g/cc. The capsules are indirectly driven inside a gold hohlraum that is 9.2 mm long by 5.75 mm in diameter. Some capsules had about 3 microns of CD on the inner surface. The CD inner surface capsules utilized HT fuel so that the DT yield arises from mixing of CD shell material into the tritium of the gas region. Our simulated results compare well to the experimental yield, ion temperature, burn width, x-ray size, convergence ratio, and radius versus time data. Work performed by Los Alamos National Laboratory under contract DE-AC52-06NA25396 for the National Nuclear Security Administration of the U.S. Department of Energy.
Progressive addition spectacle lenses: Design preferences and head movements while reading
NASA Astrophysics Data System (ADS)
Preston, Julie Lynn
In a subjective preference study, two key progressive addition lens parameters, near zone width and corridor length, were varied in a double-masked, randomized, clinical trial of 49 patients. Each subject received a complete eye examination and a new frame. Each wore 6 pairs of lenses for one week at a time and completed questionnaires relating to vision, adaptation, and satisfaction. The preferred lens was identified from the three near zone width lenses and from the three corridor length lenses. Patient characteristics were analyzed for their effect on design preference. Satisfaction ratings following a brief experience with each design were compared to ratings after one week of wear in order to ascertain the predictability of initial impressions. One lens design appeared twice in the preference trial, providing an assessment of the repeatability of the rating instrument. The lens design with the widest near zone was rated significantly lower than the other near zone width designs for nearly every question relating to vision, adaptation, and satisfaction. This lens was also least preferred of all the designs. Preferences for corridor length were evenly distributed among the three designs. Of patient characteristics, years of progressive addition lens wear and gender significantly affected design preference in this population. Initial impressions were not predictive of satisfaction after a week of wear. The rating instrument was judged to have low repeatability. In the head movement portion of the study, 18 participants from the preference study wore the three near zone width designs while reading three paragraphs of varying print size. From a 20 second recording for each of three different paragraphs with each lens, measures of head rotation and posture were collected. The amplitude of head rotation was significantly affected by print size but not by lens design. The effective zone widths on the lenses scanned by the eyes and the locations of the reading levels were calculated from the head rotation and posture data. Effective zone widths were narrower than the contour plot widths for each condition.
Al-Shami, Salman; Rawi, Che Salmah M; Nor, Siti Azizah M; Ahmad, Abu Hassan; Ali, Arshad
2010-02-01
Morphological deformities in parts of the head capsule of Chironomus spp. larvae inhabiting three polluted rivers (Permatang Rawa [PRR], Pasir [PR], and Kilang Ubi [KUR]) in the Juru River Basin, northeastern peninsular Malaysia, were studied. Samples of the fourth-instar larvae at one location in each river were collected monthly from November 2007 to March 2008 and examined for deformities of the mentum, antenna, mandible, and epipharyngis. At each sample location, in situ measurements of water depth, river width, water pH, dissolved oxygen, and water temperature were made. Samples of river water and benthic sediments were also collected monthly from each larval sample location in each river and taken to the laboratory for appropriate analysis. Total suspended solids (TSSs), ammonium-N, nitrate-N, phosphate-P, chloride, sulfate, and aluminum content in water were analyzed. Total organic matter and nonresidual metals in the sediment samples were also analyzed. Among the three rivers, the highest mean deformity (47.17%) was recorded in larvae collected from KUR that received industrial discharges from surrounding garment and rubber factories, followed by PRR (33.71%) receiving primarily residues of fertilizers and pesticides from adjacent rice fields, and PR (30.34%) contaminated primarily by anthropogenic wastes from the surrounding residential areas. Among the various head capsule structures, deformity of the mentum was strongly reflective of environmental stress and amounted to 27.9, 20.87, and 30.19% in the PRR, PR, and KUR, respectively. Calculated Lenat's toxic score index satisfactorily explained the influence of prevailing environmental variables on the severity of mentum deformities. Redundancy analysis and forward selection selected TSSs, sediment Zn, Mn, Cu, and Ni, and water pH, dissolved oxygen, water temperature, total organic matter, nitrate-N, chloride, phosphate-P, ammonium-N, sulfate, and aluminum as parameters that significantly affected some proportion of deformities. The total deformities correlated closely with deformities of mentum but only weakly with deformities in other parts of head. The total deformity incidence was strongly correlated with high contents of sediment Mn and Ni. The mentum and epipharyngis deformities incidence was highly correlated with an increase of TSSs, total aluminum, and ammonium-N and a decrease in pH and dissolved oxygen.
Mathews, Patrick D; Maia, Antônio A M; Adriano, Edson A
2016-06-01
Myxobolus niger n. sp. (Myxozoa) is described in the connective tissue of the serosa layer of the gill arch of Corydoras melini (Callichthyidae) captured from the Negro River, Amazonas State, Brazil. The prevalence of the parasite was 20% and the range intensity was 1-2 cysts per fish. The plasmodia were white and spherical to ellipsoidal, measuring 175 μm in diameter and were surrounded by a well-defined capsule of host connective tissue, with distinct delicate and interlaced collagen fibers. The myxospores body was ellipsoidal in frontal view and biconvex in sutural view. Spore dimensions were 11.3 ± 0.4 μm in length, 6.8 ± 0.2 μm in width and 4.1 ± 0.2 μm in thickness. The valves were symmetrical and smooth. The two polar capsules were elongated as pyriform and equal in size, measure 5.0 ± 0.3 μm in length and 2.0 ± 0.1 μm in width. The polar capsule had six to seven polar filament turns. Some aberrant spores were round in shape and had three polar capsules. The sporoplasm was binucleated and contained moderated number of sporoplasmosomes. The development of the plasmodia was asynchronic, with mature and immature spores. The plasmodium had moderated pynocitic channels. There were no projections, no invaginations and no microvilli in the plasmodial wall. This study is the first description of Myxobolus species in the fish of the Callichthyidae family. Copyright © 2016 Elsevier B.V. All rights reserved.
Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko; Morohashi, Itaru
2018-03-09
In total hip arthroplasty via a direct anterior approach, the femur must be elevated at the time of femoral implant placement. For adequate elevation, division of the posterior soft tissues is necessary. However, if we damage and separate the posterior muscle tissue, we lose the benefits of the intermuscular approach. Furthermore, damage to the posterior soft tissue can result in posterior dislocation. We investigate that protecting the posterior soft tissue increases the joint stability in the early postoperative period and results in a lower dislocation rate. We evaluated muscle strength recovery by measuring the maximum width of the internal obturator muscle on CT images (GE-Healthcare Discovery CT 750HD). We compared the maximum width of the muscle belly preoperatively versus 10 days and 6 months postoperatively. As clinical evaluations, we also investigated the range of motion of the hip joint, hip joint function based on the Japanese Orthopaedic Association hip score (JOA score), and the dislocation rate 6 months after surgery. The width of the internal obturator muscle increased significantly from 15.1 ± 3.1 mm before surgery to 16.4 ± 2.8 mm 6 months after surgery. The JOA score improved significantly from 50.8 ± 15.1 points to 95.6 ± 7.6 points. No dislocations occurred in this study. We cut only the posterosuperior articular capsule and protected the internal obturator muscle to preserve muscle strength. We repaired the entire posterosuperior and anterior articular capsule. These treatments increase joint stability in the early postoperative period, thus reducing the dislocation rate. Therapeutic, Level IV.
Tuhanioğlu, Ümit; Cicek, Hakan; Ogur, Hasan U; Seyfettinoglu, Firat; Kapukaya, Ahmet
2017-10-16
The goal in the treatment of developmental dysplasia of the hip (DDH) is to achieve a stable and concentric reduction and to create a congruent relationship between the femoral head and the acetabulum. This study discusses the causes of loss of reduction in DDH patients who had a concentrically reduced hip at the time of removal of the hip spica cast and cessation of brace use and who later appeared with hip redislocation after mobilisation and ambulation. In addition, the possible interventions in such cases are also discussed. A retrospective evaluation was made of 13 patients diagnosed with DDH who developed redislocation following primary surgery. 6 of them had undergone the 1st surgery in our department between 2008 and 2016 and 7 had udergone surgery in another centre. For comparison reasons a 2nd group was formed of 13 demographically and clinically matched patients who had no loss of reduction. The groups were compared in terms of acetabular index, pelvic length, pelvic width, abduction degree of plaster, ossifying nucleus diameter, acetabular depth, and acetabular volume parameters. The average age of the patients was 23 months at initial surgery and 29 months at the time of revision surgery. No significant difference was found between the groups in terms of acetabular inclination angle, ossifying nucleus diameter, pelvic size, pelvic width, centre edge angle, acetabular volume, and depth. Contracted inferomedial capsule was found in 1 patient who underwent revision surgery and intact transverse acetabular ligament was seen in 1 patient. The loss of reduction in the remaining 11 patients was associated with high total anteversion of the femoral head and acetabulum. Correction of increased combined anteversion by femoral osteotomy can create a safe zone in terms of redislocation and can significantly contribute to the stability provided by capsulorrhaphy and pelvic osteotomy.
:#ccc;text-align:center;padding:5px}.upper_button{text-align:right;padding-bottom:5px}.side_button[type ;width:175px;text-align:left;font-weight:bold;overflow:hidden}.left_head_title_alt{float:left;width:175px ;text-align:left;font-weight:bold;line-height:16px;margin-top:3px;padding-top:0}.left_head_add
NASA Astrophysics Data System (ADS)
Magelssen, G. R.; Bradley, P. A.; Tregillis, I. L.; Schmitt, M. J.; Dodd, E. S.; Wysocki, F. J.; Hsu, S. C.; Cobble, J.; Batha, S. H.; Defriend Obrey, K. A.
2010-11-01
Small capsule perturbations may impact our ability to achieve high yields on NIF. Diagnosing the hydrodynamic development and the effect of defects on burn will be difficult. Los Alamos is developing a program to better understand the hydrodynamics of defects and how they influence burn. Our first effort to study the effects of defects was on Omega. Both thin-shelled (exploding pusher) and thick-shelled capsules were shot and the results published [1]. In this work we add experimental shots done recently on Omega. These shots were to complete the study of how the width and depth of the defect affects DT yield. Our AMR code is used to predict the yield. Comparisons between capsule and experimental yields will be given. Experiments are also being designed for Polar direct drive. Our first experiments are being designed to understand the zero-order hydrodynamics with Polar direct drive. Capsules about a millimeter in radius are being designed with one to two dopants in the CH shell for radiograph and MMI usage. Also, to minimize the effect of mix on the radius versus time trajectory, some capsules will replace the DT with Xe.[0pt] [1] Magelssen G. R. et al., to be published in the 2009 IFSA proceedings.
Putzer, David; Haselbacher, Matthias; Hörmann, Romed; Klima, Günter; Nogler, Michael
2017-12-01
Surgical approaches through smaller incisions reveal less of the underlying anatomy, and therefore, detailed knowledge of the local anatomy and its variations is important in minimally invasive surgery. The aim of this study was to determine the location, extension, and histomorphology of the deep layer of the iliotibial band during minimally invasive hip surgery using the direct anterior approach (DAA). The morphology of the iliotibial tract was determined in this cadaver study on 40 hips with reference to the anterior superior iliac spine and the tibia. The deep layer of the tractus iliotibialis was exposed up to the hip-joint capsule and length and width measurements taken. Sections of the profound iliotibial tract were removed from the hips and the thickness of the sections was determined microscopically after staining. The superficial tractus iliotibialis had a length of 50.1 (SD 3.8) cm, while tensor fasciae latae total length was 18 (SD 2) cm [unattached 15 (SD 2.5) cm]. Length and width of the deep layer of the tractus iliotibialis were 10.4 (SD 1.3) × 3.3 (SD 0.6) cm. The deep iliotibial band always extended from the distal part of the tensor fascia latae (TFL) muscle to the lateral part of the hip capsule (mean maximum thickness 584 μm). Tractus iliotibialis deep layer morphology did not correlate to other measurements taken (body length, thigh length, and TFL length). The length of the deep layer is dependent on the TFL, since the profound part of the iliotibial band reaches from the TFL to the hip-joint capsule. The deep layer covers the hip-joint capsule, rectus, and lateral vastus muscles in the DAA interval. To access the precapsular fat pad and the hip-joint capsule, the deep layer has to be split in all approaches that use the direct anterior interval.
Yang, Yao Ming; Jia, Ruo; Xun, Hui; Yang, Jie; Chen, Qiang; Zeng, Xiang Guang; Yang, Ming
2018-02-21
Simulium quinquestriatum Shiraki (Diptera: Simuliidae), a human-biting fly that is distributed widely across Asia, is a vector for multiple pathogens. However, the larval development of this species is poorly understood. In this study, we determined the number of instars in this pest using three batches of field-collected larvae from Guiyang, Guizhou, China. The postgenal length, head capsule width, mandibular phragma length, and body length of 773 individuals were measured, and k-means clustering was used for instar grouping. Four distance measures-Manhattan, Euclidean, Chebyshev, and Canberra-were determined. The reported instar numbers, ranging from 4 to 11, were set as initial cluster centers for k-means clustering. The Canberra distance yielded reliable instar grouping, which was consistent with the first instar, as characterized by egg bursters and prepupae with dark histoblasts. Females and males of the last cluster of larvae were identified using Feulgen-stained gonads. Morphometric differences between the two sexes were not significant. Validation was performed using the Brooks-Dyar and Crosby rules, revealing that the larval stage of S. quinquestriatum is composed of eight instars.
Cadaveric Study of the Articular Branches of the Shoulder Joint.
Eckmann, Maxim S; Bickelhaupt, Brittany; Fehl, Jacob; Benfield, Jonathan A; Curley, Jonathan; Rahimi, Ohmid; Nagpal, Ameet S
This cadaveric study investigated the anatomic relationships of the articular branches of the suprascapular (SN), axillary (AN), and lateral pectoral nerves (LPN), which are potential targets for shoulder analgesia. Sixteen embalmed cadavers and 1 unembalmed cadaver, including 33 shoulders total, were dissected. Following dissections, fluoroscopic images were taken to propose an anatomical landmark to be used in shoulder articular branch blockade. Thirty-three shoulders from 17 total cadavers were studied. In a series of 16 shoulders, 16 (100%) of 16 had an intact SN branch innervating the posterior head of the humerus and shoulder capsule. Suprascapular sensory branches coursed laterally from the spinoglenoid notch then toward the glenohumeral joint capsule posteriorly. Axillary nerve articular branches innervated the posterolateral head of the humerus and shoulder capsule in the same 16 (100%) of 16 shoulders. The AN gave branches ascending circumferentially from the quadrangular space to the posterolateral humerus, deep to the deltoid, and inserting at the inferior portion of the posterior joint capsule. In 4 previously dissected and 17 distinct shoulders, intact LPNs could be identified in 14 (67%) of 21 specimens. Of these, 12 (86%) of 14 had articular branches innervating the anterior shoulder joint, and 14 (100%) of 14 LPN articular branches were adjacent to acromial branches of the thoracoacromial blood vessels over the superior aspect of the coracoid process. Articular branches from the SN, AN, and LPN were identified. Articular branches of the SN and AN insert into the capsule overlying the glenohumeral joint posteriorly. Articular branches of the LPN exist and innervate a portion of the anterior shoulder joint.
Magnetically Actuated Soft Capsule With the Multimodal Drug Release Function
Yim, Sehyuk; Goyal, Kartik; Sitti, Metin
2014-01-01
In this paper, we present a magnetically actuated multimodal drug release mechanism using a tetherless soft capsule endoscope for the treatment of gastric disease. Because the designed capsule has a drug chamber between both magnetic heads, if it is compressed by the external magnetic field, the capsule could release a drug in a specific position locally. The capsule is designed to release a drug in two modes according to the situation. In the first mode, a small amount of drug is continuously released by a series of pulse type magnetic field (0.01–0.03 T). The experimental results show that the drug release can be controlled by the frequency of the external magnetic pulse. In the second mode, about 800 mm3 of drug is released by the external magnetic field of 0.07 T, which induces a stronger magnetic attraction than the critical force for capsule’s collapsing. As a result, a polymeric coating is formed around the capsule. The coated area is dependent on the drug viscosity. This paper presents simulations and various experiments to evaluate the magnetically actuated multimodal drug release capability. The proposed soft capsules could be used as minimally invasive tetherless medical devices with therapeutic capability for the next generation capsule endoscopy. PMID:25378896
Probing the Physics of Burning DT Capsules Using Gamma-ray Diagnostics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayes-Sterbenz, Anna Catherine; Hale, Gerald M.; Jungman, Gerard
2015-02-01
The Gamma Reaction History (GRH) diagnostic developed and lead by the Los Alamos National Laboratory GRH Team is used to determine the bang time and burn width of imploded inertial confinement fusion capsules at the National Ignition Facility. The GRH team is conceptualizing and designing a new Gamma-to-Electron Magnetic Spectrometer (GEMS), that would be capable of an energy resolution ΔE/E~3-5%. In this whitepaper we examine the physics that could be explored by the combination of these two gamma-ray diagnostics, with an emphasis on the sensitivity needed for measurements. The main areas that we consider are hydrodynamical mixing, ablator areal densitymore » and density profile, and temporal variations of the density of the cold fuel and the ablator during the DT burn of the capsule.« less
Development of three-layered rumen escapable capsules for cattle
SEYAMA, Tomohiro; HIRAYASU, Hirofumi; YAMAWAKI, Kenji; ADACHI, Takuhiko; SUGIMOTO, Takayuki; KASAI, Koji
2016-01-01
A new rumen escapable tool is presented for cattle in prospect of developing medical treatment or supplementing trace elements for disease prevention. This tool consists of a three-layered capsule that dissolves in the lower digestive tract, but not in the rumen. The capsule was manufactured by capsule-forming techniques through the use of liquid surface tension. This method does not involve high-temperature treatment, so the capsule can contain not only lipophilic substances but also hydrophilic or heat-sensitive substances. Furthermore, the capsule has a specific gravity of 1.3 and diameter of 6.0 mm, which were previously shown to be appropriate to avoid rumination. The objective of this study was to confirm the effectiveness of the capsule pertinent to rumen escaping. In order to validate rumen escape, capsules containing 30 g of water-soluble vitamin (thiamine hydrochloride) per head were administered to four lactating cows assigned in a crossover trial. In the group administered encapsulated thiamine hydrochloride, blood thiamine levels increased from 12.4 ± 1.03 ng/ml before administration to 54.8 ± 2.21 ng/ml at 6 hr following administration, whereas the level remained at 13.3 ± 2.05 ng/ml in the control group administered via aqueous solution. This indicates that the three-layered capsules passed through the rumen and dissolved in the lower digestive tract, thus functioning as a rumen escapable tool. PMID:27546371
Bao, Guzhi; Wickenbrock, Arne; Rochester, Simon; Zhang, Weiping; Budker, Dmitry
2018-01-19
The nonlinear Zeeman effect can induce splitting and asymmetries of magnetic-resonance lines in the geophysical magnetic-field range. This is a major source of "heading error" for scalar atomic magnetometers. We demonstrate a method to suppress the nonlinear Zeeman effect and heading error based on spin locking. In an all-optical synchronously pumped magnetometer with separate pump and probe beams, we apply a radio-frequency field which is in phase with the precessing magnetization. This results in the collapse of the multicomponent asymmetric magnetic-resonance line with ∼100 Hz width in the Earth-field range into a single peak with a width of 22 Hz, whose position is largely independent of the orientation of the sensor within a range of orientation angles. The technique is expected to be broadly applicable in practical magnetometry, potentially boosting the sensitivity and accuracy of Earth-surveying magnetometers by increasing the magnetic-resonance amplitude, decreasing its width, and removing the important and limiting heading-error systematic.
Surprising evidence of pelvic growth (widening) after skeletal maturity.
Berger, Alexander A; May, Ryan; Renner, Jordan B; Viradia, Neal; Dahners, Laurence E
2011-11-01
Following an increase in length and width during childhood and adolescence, skeletal growth is generally assumed to stop. This study investigates the influence of aging on the dimensions of the pelvis and the L4 lumbar vertebra during adulthood. The dimensions of the pelvis, L4 vertebra, and femoral heads were calculated for 246 patients who had received pelvic and abdominal Computed Tomography scans from the UNC Health Care System. Linear regression analysis determined the significance of relationships between age and width of the pelvis. There was a strong correlation between increasing patient age and increasing width of the pelvis at the trochanters, (0.333 mm/year of age p<0.0001), at the iliac wings, (0.371 mm/year of age p < 0.0002), and between the femoral heads, indicating that the bony pelvis widens over 20 mm between the ages of 20 and 80. The pelvic inlet did not enlarge over time while the distance between the hips and the femoral head diameter did significantly increase. The height of L4 did not increase over time, but the L4 width did increase. These correlations were seen in both genders. Surprisingly, our results suggest that the pelvis and L4 vertebra increase in width after skeletal maturity and cessation of longitudinal growth. Copyright © 2011 Orthopaedic Research Society.
Sato, Shun'ichi; Inoda, Toshio; Niitsu, Shuhei; Kubota, Souichirou; Goto, Yuji; Kobayashi, Yukimasa
2017-11-01
The larvae of a water scavenger beetle, Hydrophilus acuminatus, have strongly asymmetric mandibles; the right one is long and slender, whereas the left one is short and stout. The fine structure and embryonic development of the head capsule and mandibles of this species were examined using light and scanning electron microscopy, and asymmetries in shape were detected in these structures applying an elliptic Fourier analysis. The larval mandibles are asymmetric in the following aspects: whole length, the number, structure and arrangement of retinacula (inner teeth), and size and shape of both the molar and incisor regions. The larval head is also asymmetric; the left half of the head capsule is larger than the right, and the left adductor muscle of the mandible is much thicker than the right. The origin and developmental process of asymmetric mandibles were traced in developing embryos whose developmental period is about 270 h and divided into 10 stages. Mandibular asymmetries are produced by the cumulative effects of six stepwise modifications that occur from about 36% of the total developmental time onward. The significance of these modifications was discussed with respect to the functional advantages of asymmetries and the phylogeny of members of the Hydrophilidae. Copyright © 2017 Elsevier Ltd. All rights reserved.
Iwanowicz, Luke R; Iwanowicz, Deborah D; Pote, Linda M; Blazer, Vicki S; Schill, William B
2008-02-01
Henneguya gurlei was isolated from Ameiurus nebulosus captured in North Carolina and redescribed using critical morphological features and 18S small-subunit ribosomal RNA (SSU rDNA) gene sequence. Plasmodia are white, spherical, or subspherical, occur in clusters, measure up to 1.8 mm in length, and are located on the dorsal, pectoral, and anal fins. Histologically, plasmodia are located in the dermis and subdermally, and the larger cysts disrupt the melanocyte pigment layer. The spore body is lanceolate, 18.2 +/- 0.3 microm (range 15.7-20.3) in length, and 5.4 +/- 0.1 microm (range 3.8-6.1) in width in valvular view. The caudal appendages are 41.1 +/- 1.1 microm (range 34.0-49.7) in length. Polar capsules are pyriform and of unequal size. The longer polar capsule measures 6.2 +/- 0.1 microm (range 5.48-7.06), while the shorter is 5.7 +/- 0.1 microm (range 4.8-6.4) in length. Polar capsule width is 1.2 +/- 0.03 microm (range 1.0-1.54). The total length of the spore is 60.9 +/- 1.2 microm (range 48.7-68.5). Morphologically, this species is similar to other species of Henneguya that are known to infect ictalurids. Based on SSU rDNA sequences, this species is most closely related to H. exilis and H. ictaluri, which infect Ictalurus punctatus.
Iwanowicz, L.R.; Iwanowicz, D.D.; Pote, L.M.; Blazer, V.S.; Schill, W.B.
2008-01-01
Henneguya gurlei was isolated from Ameiurus nebulosus captured in North Carolina and redescribed using critical morphological features and 18S small-subunit ribosomal RNA (SSU rDNA) gene sequence. Plasmodia are white, spherical, or subspherical, occur in clusters, measure up to 1.8 mm in length, and are located on the dorsal, pectoral, and anal fins. Histologically, plasmodia are located in the dermis and subdermally, and the larger cysts disrupt the melanocyte pigment layer. The spore body is lanceolate, 18.2 ?? 0.3 ??m (range 15.7-20.3) in length, and 5.4 ?? 0.1 ??m (range 3.8-6.1) in width in valvular view. The caudal appendages are 41.1 ?? 1.1 ??m (range 34.0-49.7) in length. Polar capsules are pyriform and of unequal size. The longer polar capsule measures 6.2 ?? 0.1 ??m (range 5.48-7.06), while the shorter is 5.7 ?? 0.1 ??m (range 4.8-6.4) in length. Polar capsule width is 1.2 ?? 0.03 ??m (range 1.0-1.54). The total length of the spore is 60.9 ?? 1.2 ??m (range 48.7-68.5). Morphologically, this species is similar to other species of Henneguya that are known to infect ictalurids. Based on SSU rDNA sequences, this species is most closely related to H. exilis and H. ictaluri, which infect Ictalurus punctatus. ?? American Society of Parasitologists 2008.
A Genome-Wide Association Study Identifies Multiple Regions Associated with Head Size in Catfish
Geng, Xin; Liu, Shikai; Yao, Jun; Bao, Lisui; Zhang, Jiaren; Li, Chao; Wang, Ruijia; Sha, Jin; Zeng, Peng; Zhi, Degui; Liu, Zhanjiang
2016-01-01
Skull morphology is fundamental to evolution and the biological adaptation of species to their environments. With aquaculture fish species, head size is also important for economic reasons because it has a direct impact on fillet yield. However, little is known about the underlying genetic basis of head size. Catfish is the primary aquaculture species in the United States. In this study, we performed a genome-wide association study using the catfish 250K SNP array with backcross hybrid catfish to map the QTL for head size (head length, head width, and head depth). One significantly associated region on linkage group (LG) 7 was identified for head length. In addition, LGs 7, 9, and 16 contain suggestively associated regions for head length. For head width, significantly associated regions were found on LG9, and additional suggestively associated regions were identified on LGs 5 and 7. No region was found associated with head depth. Head size genetic loci were mapped in catfish to genomic regions with candidate genes involved in bone development. Comparative analysis indicated that homologs of several candidate genes are also involved in skull morphology in various other species ranging from amphibian to mammalian species, suggesting possible evolutionary conservation of those genes in the control of skull morphologies. PMID:27558670
A Simple Ground-Based Trap For Estimating Densities of Arboreal Leaf Insects
Robert A. Haack; Richard W. Blank
1991-01-01
Describes a trap design to use in collecting larval frass or head capsules for estimating densities of aboveground arthropods. The trap is light, compact, durable, and easily constructed from common inexpensive items.
SU-E-I-27: Estimating KERMA Area Product for CT Localizer Images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ogden, K; Greene-Donnelly, K; Bennett, R
2015-06-15
Purpose: To estimate the free-in-air KERMA-Area Product (KAP) incident on patients due to CT localizer scans for common CT exams. Methods: In-plane beam intensity profiles were measured in localizer acquisition mode using OSLs for a 64 slice MDCT scanner (Lightspeed VCT, GE Medical Systems, Waukesha WI). The z-axis beam width was measured as a function of distance from isocenter. The beam profile and width were used to calculate a weighted average air KERMA per unit mAs as a function of intercepted x-axis beam width for objects symmetric about the localizer centerline.Patient areas were measured using manually drawn regions and dividedmore » by localizer length to determine average width. Data were collected for 50 head exams (lateral localizer only), 15 head/neck exams, 50 chest exams, and 50 abdomen/pelvis exams. Mean patient widths and acquisition techniques were used to calculate the weighted average free-in-air KERMA, which was multiplied by the patient area to estimate KAP. Results: Scan technique was 120 kV tube voltage, 10 mA current, and table speed of 10 cm/s. The mean ± standard deviation values of KAP were 120 ± 11.6, 469 ± 62.6, 518 ± 45, and 763 ± 93 mGycm{sup 2} for head, head/neck, chest, and abdomen/pelvis exams, respectively. For studies with AP and lateral localizers, the AP/lateral area ratio was 1.20, 1.33, and 1.24 for the head/neck, chest, and abdomen/pelvis exams, respectively. However, the AP/lateral KAP ratios were 1.12, 1.08, and 1.07, respectively. Conclusion: Calculation of KAP in CT localizers is complicated by the non-uniform intensity profile and z-axis beam width. KAP values are similar to those for simple radiographic exams such as a chest radiograph and represent a small fraction of the x-ray exposure at CT. However, as CT doses are reduced the localizer contribution will be a more significant fraction of the total exposure.« less
Gans, Itai; Sankar, Wudbhav N
2014-12-01
Closed reduction (CR) and spica casting is performed using arthrography to assess the adequacy of reduction based in part on the width of medial dye pool (MDP); however, the amount of MDP that is acceptable and its correlation to the actual anatomic position of the femoral head within the acetabulum has been poorly delineated. The purpose of this study was to determine this correlation and to explore the potential limits of acceptable MDP measurements. We retrospectively reviewed a consecutive series of patients with DDH treated at our institution by CR and immediate postoperative magnetic resonance imaging (MRI) and found 20 patients (23 hips) meeting inclusion criteria. We measured the MDP and femoral head area on the best reduced arthrographic image, the immediate postoperative mid-coronal MRI, and on 3 planes (neutral, 30-degree anterior, and 30-degree posterior) of the mid-axial MRI and compared MDP values from both imaging modalities using the Pearson correlation coefficient (R). To provide useful data for establishing intraoperative thresholds, MDP was also expressed as a percentage of femoral head width to control for fluoroscopic magnification. Twenty-two of the 23 hips were reduced on postoperative MRI; the one persistently dislocated hip was excluded from our analysis. The Pearson correlation coefficient was R = 0.73 comparing arthrography and coronal MRI, indicating excellent correlation. Correlation was even stronger between arthrography and axial MRI (neutral R = 0.73; 30-degree anterior, R = 0.81; 30-degree posterior, R = 0.81). The mean fluoroscopic MDP in the successful, fully concentric, CRs was 4.2% of the femoral head width (range, 0.6% to 15.8%). There is very strong correlation between MDP measurements on arthrography and immediate postoperative MRI in both the axial and coronal planes. On the basis of our data, an arthrographic MDP between 0.6% and 15.8% of the femoral head width always resulted in an excellent reduction, suggesting that an MDP of ≤ 16% of femoral head width may be a useful intraoperative criterion for determining the adequacy of CR. Level I Diagnostic Study.
Wetted foam liquid fuel ICF target experiments
Olson, R. E.; Leeper, R. J.; Yi, S. A.; ...
2016-05-26
We are developing a new NIF experimental platform that employs wetted foam liquid fuel layer ICF capsules. We will use the liquid fuel layer capsules in a NIF sub-scale experimental campaign to explore the relationship between hot spot convergence ratio (CR) and the predictability of hot spot formation. DT liquid layer ICF capsules allow for flexibility in hot spot CR via the adjustment of the initial cryogenic capsule temperature and, hence, DT vapor density. Our hypothesis is that the predictive capability of hot spot formation is robust and 1D-like for a relatively low CR hot spot (CR~15), but will becomemore » less reliable as hot spot CR is increased to CR>20. Simulations indicate that backing off on hot spot CR is an excellent way to reduce capsule instability growth and to improve robustness to low-mode x-ray flux asymmetries. In the initial experiments, we will test our hypothesis by measuring hot spot size, neutron yield, ion temperature, and burn width to infer hot spot pressure and compare to predictions for implosions with hot spot CR's in the range of 12 to 25. Larger scale experiments are also being designed, and we will advance from sub-scale to full-scale NIF experiments to determine if 1D-like behavior at low CR is retained as the scale-size is increased. The long-term objective is to develop a liquid fuel layer ICF capsule platform with robust thermonuclear burn, modest CR, and significant α-heating with burn propagation.« less
ZUHARAH, Wan Fatma; AHBIRAMI, Rattanam; DIENG, Hamady; THIAGALETCHUMI, Maniam; FADZLY, Nik
2016-01-01
Plant derived insecticides have considerable potential for mosquito control because these products are safer than conventional insecticides. This study aimed to investigate sublethal activities of Ipomoea carica or railway creeper crude acethonilic extract against life history trait of dengue vectors, Aedes albopictus and Aedes aegypti. The late third instar larvae of Ae. albopictus and Ae. aegypti were exposed to a sublethal dose at LC50 and larvae that survived were further cultured. Overall, Ipomea cairica crude extracts affected the whole life history of both Aedes species. The study demonstrated significantly lower egg production (fecundity) and eggs hatchability (fertility) in Ae. albopictus. The sublethal dose of crude extracts reduced significantly the width of larval head capsule and the wing length of both sexes in both Aedes species. The significance of sublethal effects of I. cairica against Aedes mosquitoes was an additional hallmark to demonstrate further activity of this plant despite its direct toxicity to the larvae. The reduced reproductive capacity as well as morphological and physiological anomalies are some of the effects that make I. cairica a potential candidate to be used as a new plant-based insecticide to control dengue vectors. PMID:27253746
Wen, Zhimou; Chen, Jeng Shong
2018-05-26
We report here a simple and sensitive plant-based western corn rootworm, Diabrotica virgifera virgifera LeConte (Coleoptera: Chrysomelidae), bioassay method that allows for examination of multiple parameters for both plants and insects in a single experimental setup within a short duration. For plants, injury to roots can be visually examined, fresh root weight can be measured, and expression of trait protein in plant roots can be analyzed. For insects, in addition to survival, larval growth and development can be evaluated in several aspects including body weight gain, body length, and head capsule width. We demonstrated using the method that eCry3.1Ab-expressing 5307 corn was very effective against western corn rootworm by eliciting high mortality and significantly inhibiting larval growth and development. We also validated that the method allowed determination of resistance in an eCry3.1Ab-resistant western corn rootworm strain. While data presented in this paper demonstrate the usefulness of the method for selection of events of protein traits and for determination of resistance in laboratory populations, we envision that the method can be applied in much broader applications.
Han, Lu; Long, Ting; Tang, Wei; Liu, Lei; Jing, Wei; Tian, Wei-Dong; Long, Jie
2017-02-20
The treatment of the condylar fractures is difficult. Factors that result in the fractures are complex. The objective of this morphometric study was to investigate the relationship between condylar fracture patterns and condylar morphological characteristics. We conducted a retrospective analysis of 107 patients admitted to the West China Hospital of Stomatology for bilateral condylar fractures caused by parasymphyseal impact. The patients were divided into five groups according to the type of condylar fracture. Ten parameters were evaluated on three-dimensional (3D) reconstruction mandible models through the Mimics 16.0 (Materialize Leuven, Belgium) anthropometry toolkit. Each parameter of the 3D models was analyzed using multivariate analysis. Multinomial logistic regression analyses were used to examine the relationships between the five groups. The results showed that the differences of condylar head width (M1), condylar neck width (M3), the ratio of condylar head width to condylar anteroposterior diameter (M1/M2), the ratio of condylar head width to condylar neck width (M1/M3), the ratio of condylar height to ramus height (M8/M7), and mandibular angle (M10) were statistically significant (p < 0.05). Type A condylar head fractures were positively associated with M1 (compared to Type B: OR =1.627, 95% CI: 1.123, 2.359; compared to Type C: OR = 1.705, 95% CI: 1.170, 2.484) and M1/M2 (compared to Type B: OR =1.034, 95% CI: 0.879, 2.484). Type B condylar head fractures were negatively associated with M10 (compared to Type C: OR = 0.909, 95% CI: 0.821, 1.007). Condylar neck fractures were negatively associated with M3 (compared to condylar head: OR = 0.382, CI: 0.203, 0.720 ; compared to condylar base: OR = 0.436, 95% CI: 0.218, 0.874), and positively associated with M1/M3 (compared to condylar head: OR = 1.229, 95% CI: 1.063, 1.420 compared to condylar base: OR = 1.223, 95% CI: 1.034, 1.447). Condylar base fractures were positively associated with M10 (OR = 1.095, 95% CI: 1.008, 1.189) and negatively associated with M8/M7 (OR = 0.855, 95% CI: 0.763, 0.959) as compared with condylar head fractures. Condylar fracture pattern is associated with the anatomical features of the condyles when a fracture occurs from parasymphyseal impact.
Han, Lu; Long, Ting; Tang, Wei; Liu, Lei; Jing, Wei; Tian, Wei-Dong; Long, Jie
2017-01-01
Background: The treatment of the condylar fractures is difficult. Factors that result in the fractures are complex. The objective of this morphometric study was to investigate the relationship between condylar fracture patterns and condylar morphological characteristics. Methods: We conducted a retrospective analysis of 107 patients admitted to the West China Hospital of Stomatology for bilateral condylar fractures caused by parasymphyseal impact. The patients were divided into five groups according to the type of condylar fracture. Ten parameters were evaluated on three-dimensional (3D) reconstruction mandible models through the Mimics 16.0 (Materialize Leuven, Belgium) anthropometry toolkit. Each parameter of the 3D models was analyzed using multivariate analysis. Multinomial logistic regression analyses were used to examine the relationships between the five groups. Results: The results showed that the differences of condylar head width (M1), condylar neck width (M3), the ratio of condylar head width to condylar anteroposterior diameter (M1/M2), the ratio of condylar head width to condylar neck width (M1/M3), the ratio of condylar height to ramus height (M8/M7), and mandibular angle (M10) were statistically significant (p < 0.05). Type A condylar head fractures were positively associated with M1 (compared to Type B: OR =1.627, 95% CI: 1.123, 2.359; compared to Type C: OR = 1.705, 95% CI: 1.170, 2.484) and M1/M2 (compared to Type B: OR =1.034, 95% CI: 0.879, 2.484). Type B condylar head fractures were negatively associated with M10 (compared to Type C: OR = 0.909, 95% CI: 0.821, 1.007). Condylar neck fractures were negatively associated with M3 (compared to condylar head: OR = 0.382, CI: 0.203, 0.720; compared to condylar base: OR = 0.436, 95% CI: 0.218, 0.874), and positively associated with M1/M3 (compared to condylar head: OR = 1.229, 95% CI: 1.063, 1.420 compared to condylar base: OR = 1.223, 95% CI: 1.034, 1.447). Condylar base fractures were positively associated with M10 (OR = 1.095, 95% CI: 1.008, 1.189) and negatively associated with M8/M7 (OR = 0.855, 95% CI: 0.763, 0.959) as compared with condylar head fractures. Conclusions: Condylar fracture pattern is associated with the anatomical features of the condyles when a fracture occurs from parasymphyseal impact. PMID:28218215
NASA Technical Reports Server (NTRS)
1983-01-01
Existing high energy tapes, high track density heads, and transport guidance techniques were evaluated and characterized to enable these technologies to be employed in future spacecraft recorders with high confidence. The results of these study efforts demonstrated tracking accuracy tape and head density that will support spacecraft recorders with data rates of a minimum of 150 Mbps and storage capacities ranging from 10 to the 10th to 10 to the 11th bits. Seven high energy tapes of either .25 in width, 1.00 in width, or both, were tested. All tapes were tested at the same speed (30 ips) and the same packing density (33 KBI). The performance of all 1 in tapes was considered superior.
A Statistical Skull Geometry Model for Children 0-3 Years Old
Li, Zhigang; Park, Byoung-Keon; Liu, Weiguo; Zhang, Jinhuan; Reed, Matthew P.; Rupp, Jonathan D.; Hoff, Carrie N.; Hu, Jingwen
2015-01-01
Head injury is the leading cause of fatality and long-term disability for children. Pediatric heads change rapidly in both size and shape during growth, especially for children under 3 years old (YO). To accurately assess the head injury risks for children, it is necessary to understand the geometry of the pediatric head and how morphologic features influence injury causation within the 0–3 YO population. In this study, head CT scans from fifty-six 0–3 YO children were used to develop a statistical model of pediatric skull geometry. Geometric features important for injury prediction, including skull size and shape, skull thickness and suture width, along with their variations among the sample population, were quantified through a series of image and statistical analyses. The size and shape of the pediatric skull change significantly with age and head circumference. The skull thickness and suture width vary with age, head circumference and location, which will have important effects on skull stiffness and injury prediction. The statistical geometry model developed in this study can provide a geometrical basis for future development of child anthropomorphic test devices and pediatric head finite element models. PMID:25992998
A statistical skull geometry model for children 0-3 years old.
Li, Zhigang; Park, Byoung-Keon; Liu, Weiguo; Zhang, Jinhuan; Reed, Matthew P; Rupp, Jonathan D; Hoff, Carrie N; Hu, Jingwen
2015-01-01
Head injury is the leading cause of fatality and long-term disability for children. Pediatric heads change rapidly in both size and shape during growth, especially for children under 3 years old (YO). To accurately assess the head injury risks for children, it is necessary to understand the geometry of the pediatric head and how morphologic features influence injury causation within the 0-3 YO population. In this study, head CT scans from fifty-six 0-3 YO children were used to develop a statistical model of pediatric skull geometry. Geometric features important for injury prediction, including skull size and shape, skull thickness and suture width, along with their variations among the sample population, were quantified through a series of image and statistical analyses. The size and shape of the pediatric skull change significantly with age and head circumference. The skull thickness and suture width vary with age, head circumference and location, which will have important effects on skull stiffness and injury prediction. The statistical geometry model developed in this study can provide a geometrical basis for future development of child anthropomorphic test devices and pediatric head finite element models.
Evaluation of HeadLight: An E-Construction Inspection Technology : research project capsule
DOT National Transportation Integrated Search
2017-09-01
Project delivery and inspection are challenging, resource-intensive jobs. The quality/accuracy of collected field data is crucial. The Louisiana Department of Transportation and Development (DOTD) still relies on a primarily paper-based process for f...
Morphometric changes in boar spermatozoa induced by cryopreservation.
García-Herreros, M; Barón, F J; Aparicio, I M; Santos, A J; García-Marín, L J; Gil, M C
2008-09-01
Computer-assisted sperm morphometry analysis was used to determine the effects of cryopreservation on boar sperm head and midpiece morphometry. Sperm-rich fractions were collected from five mature boars. Three microscope slides were prepared from single extended sperm samples prior freezing and post-thawing. All slides were stained with Hemacolor, and 250 sperm images were obtained from each slide. The sperm head dimensions for length, width, area, perimeter and four shape factors and sperm-midpiece dimensions for area, width, angle and distance were determined in each spermatozoa. The effects of sperm freezing on sperm dimensions within and among boars were determined. A previous discriminant analysis of the results was able to correctly classify a 78.3 and 82% of fresh and frozen-thawed spermatozoa respectively. Sperm heads were significantly smaller in cryopreserved spermatozoa than in the companion extended samples for length, width, area and perimeter. Sperm midpieces were also significantly smaller in cryopreserved spermatozoa for width and area. The highest changes in morphometric dimensions after the freeze-thawing process were found in the midpiece of spermatozoa. The variability of morphometric measurements only was significantly different between fresh and thawed samples for head rugosity and midpiece area. The effects of cryopreservation on morphometric parameters were similar in the boars, which allow us to conclude that cryopreservation process does not have a different effect in each individual boar. In summary, morphometric changes associated with the cryopreservation process on boar spermatozoa do not apparently depends on an effect at individual level.
The Defect Induced Mix Experiment (DIME) for NIF
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmitt, Mark J; Bradley, Paul A; Cobble, James A
2012-06-18
LANL will perform two Defect Induced Mix Experiment (DIME) implosion campaigns on NIF in July and September, 2012. This presentation describes the goals for these shots and the experimental configuration and diagnostic set up to collect the appropriate data. The first two-shot campaign will focus on executing polar direct drive (PDD) implosions of plastic CH capsules filled with deuterium gas. Gas filling will be performed through a fill tube at target chamber center. A vanadium backligher foil will provide x-rays to radiograph the last half of the implosion to compare the implosion trajectory with modeling predictions. An equatorial groove inmore » one of the capsules will be present to determine its effect on implosion dynamics. The second DIME campaign will commission and use a spectral imager (MMI) to examine the evolution of thin capsule layers doped with either Ge or Ga at 1.85%. Spectral line emission from these layers will quantify the mix width at the inner shell radius and near an equatorial groove feature.« less
Kang, Hee-Woong; Jo, Yeong-Rok; Kang, Duk-Yong; Jeong, Gyeong-Suk; Jo, Hyun-Su
2013-09-01
The gonadsomatic index (GSI) of mottled skate was the highest in April, GSI and HSI showed a reverse phase for its reproductive cycle. The fish had one pair of egg capsules, having 1 to 7 fertilized eggs, and spawned all the year round. When surveying the reproductive characteristics of females over 63 ㎝ in disc width, we found the spawning peak was between April to June, and the appearance ratio of egg capsules was the highest in May (32.1%). The eggs were hatched at 8°C, 13°C, 18°C, water temperature (12.8 to 24.2°C), and the best hatching temperature was 18°C. The number of fish hatched was 4 to 5 fish/egg capsules, and the hatching rate was 100%. The sex ratios of hatching larvae were 45.5% female and 54.5% male. Therefore this study will provide fundamental data and information for artificial reproduction of the mottled skate.
Kang, Hee-Woong; Jo, Yeong-Rok; Kang, Duk-Yong; Jeong, Gyeong-Suk; Jo, Hyun-Su
2013-01-01
The gonadsomatic index (GSI) of mottled skate was the highest in April, GSI and HSI showed a reverse phase for its reproductive cycle. The fish had one pair of egg capsules, having 1 to 7 fertilized eggs, and spawned all the year round. When surveying the reproductive characteristics of females over 63 ㎝ in disc width, we found the spawning peak was between April to June, and the appearance ratio of egg capsules was the highest in May (32.1%). The eggs were hatched at 8°C, 13°C, 18°C, water temperature (12.8 to 24.2°C), and the best hatching temperature was 18°C. The number of fish hatched was 4 to 5 fish/egg capsules, and the hatching rate was 100%. The sex ratios of hatching larvae were 45.5% female and 54.5% male. Therefore this study will provide fundamental data and information for artificial reproduction of the mottled skate. PMID:25949140
Is Canyon Width a Diagnostic Indicator of the Discharge of Megafloods on Earth and Mars?
NASA Astrophysics Data System (ADS)
Lapotre, M. G.; Lamb, M. P.
2013-12-01
On Earth, large floods have carved steep-walled and amphitheater-headed canyons from the Pleistocene (e.g. Box Canyon, ID) through the Holocene (e.g. Asbyrgi Canyon, Iceland), to historic times (e.g. Canyon Lake Gorge, TX). The geologic record on Mars suggests that similar floods have carved canyons by waterfall retreat about 3.5 billion years ago, when the red planet was wetter and possibly warmer. We currently lack robust paleo-hydraulic tools to reconstruct the discharge of ancient floods, especially on Mars where sediment sizes are obscured from observation. To address this issue, we hypothesize that the width of canyon escarpment is controlled by the hydraulics of the canyon-carving flood due to focusing of the flood into the canyon head. We compiled field data from multiple canyons and floods on Earth and Mars and show that there is a correlation between estimated flood discharge and canyon headwall width. To explore what sets this relationship, we identified five important parameters using dimensional analysis: the Froude number, the ratio of backwater length to canyon length, the ratio of backwater length to flood width, the ratio of canyon width to flood width, and the topographic slope upstream of the canyon. We used the hydraulic numerical modeling suite ANUGA to simulate overland flow over different canyon geometries and flood parameters to systematically explore the relative bed shear stresses along the canyon rim as a metric for flow focusing. Results show that canyons that exceed a certain length, scaling with the hydraulic backwater length, have shear stresses at their heads that are significantly higher than near the canyon mouth. Shear stresses along the rim of the canyon sidewalls are limited, in comparison to stresses along the canyon head, when the flood width is of the order of the backwater length. Flow focusing only occurs for subcritical flow. Together, these results suggest that canyons may only grow from a perturbation that is large enough to instigate flow focusing. Once canyon growth is initiated, the equilibrium width of canyons may arise from the competition between the cross-stream backwater effects along the canyon sidewalls, which promote widening of the escarpment, and the geometry of the canyon flood system, which promote a drying of the canyon sidewalls. These results show promise for a new paleohydraulic tool to infer discharges of ancient floods on Earth and Mars.
NASA Astrophysics Data System (ADS)
Lapotre, Mathieu; Lamb, Michael
2013-04-01
Canyons carved by outburst floods are common landforms on Earth and Mars. These canyons are generally found in fractured basalts and jointed sedimentary rocks. Flood-carved canyons commonly have steep headwalls and a roughly constant width, and are often thought to have formed from upstream headwall propagation due to waterfall erosion. Because morphology is readily available from satellite imagery, these canyons offer a unique opportunity to quantify the discharge of rare, catastrophic paleo-floods on Earth and Mars. However, mechanistic relationships that relate canyon size to flood discharge have yet to be developed. We propose that the width of a canyon headwall in fractured rock is set by the spatial distribution of erosion around the rim of the canyon, which is controlled by the distribution of shear stresses induced by the overflowing water as it is focused into the canyon head. We test this hypothesis by performing a series of numerical simulations of flood-water focusing using ANUGA Hydro, a 2D-depth averaged, fully turbulent, hydraulic numerical modeling suite allowing for Froude-number transitions. The numerical simulations were designed to explore five dimensionless variables: the aspect ratio of the canyon (length normalized by width), the canyon width to flood-water width ratio, the canyon width to normal-flow depth ratio, the Froude number, and the topographic gradient upstream of the canyon. Preliminary results show that flow focusing leads to increased shear stresses at the canyon head compared to the sides of the canyon for subcritical floods and higher canyon aspect ratios. This suggests that proto-canyons start growing from a topographic defect in all directions until they reach a critical length for the side walls to dry. Once this critical length is attained, canyons focus most of the flood waters into their heads, and propagate upstream only, maintaining roughly constant widths. Preliminary results suggest that canyon width may be used to reconstruct the discharge of paleo-flood events on Mars and Earth.
A new termite (Isoptera, Termitidae, Syntermitinae, Macuxitermes) from Colombia
Postle, Anthony C.; Scheffrahn, Rudolf H.
2016-01-01
Abstract A new species of termite, Macuxitermes colombicus Postle & Scheffrahn is described from soldiers and workers collected from Departamento Magdalena, Colombia. The soldier of Macuxitermes colombicus differs from its lone congener in having no protuberances on the head capsule. PMID:27408525
2011-12-02
CAPE CANAVERAL, Fla. – NASA's Liberty Star ship heads into the Atlantic Ocean where tests will be performed on an Orion flight test capsule. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
Flaherty, Alice W; Williams, Ziv M; Amirnovin, Ramin; Kasper, Ekkehard; Rauch, Scott L; Cosgrove, G Rees; Eskandar, Emad N
2005-10-01
Medical treatment of Tourette syndrome is often ineffective or is accompanied by debilitating side effects, therefore prompting the need to evaluate surgical therapies. We present the case of a 37-year-old woman with severe Tourette syndrome since the age of 10 years. Her symptoms included frequent vocalizations and severe head and arm jerks that resulted in unilateral blindness. Trials of more than 40 medications and other therapies had failed to relieve the tics. We implanted bilateral electrodes in the anterior limb of the internal capsule, terminating in the vicinity of the nucleus accumbens. At 18-month follow-up, optimal stimulation continued to lower her tic frequency and severity significantly. Our findings suggest that stimulation of the anterior internal capsule may be a safe and effective procedure for the treatment of Tourette syndrome.
Bean alpha-amylase inhibitors in transgenic peas inhibit development of pea weevil larvae.
de Sousa-Majer, Maria José; Hardie, Darryl C; Turner, Neil C; Higgins, Thomas J V
2007-08-01
This glasshouse study used an improved larval measurement procedure to evaluate the impact of transgenic pea, Pisum sativum L., seeds expressing a-amylase inhibitor (AI)-1 or -2 proteins on pea weevil, Bruchus pisorum L. Seeds of transgenic 'Laura' and 'Greenfeast' peas expressing alpha-(AI)-1 reduced pea weevil survival by 93-98%. Larval mortality occurred at an early instar. Conversely, in nontransgenic cultivars, approximately 98-99% of the pea weevils emerged as adults. By measuring the head capsule size, we determined that larvae died at the first to early third instar in alpha-(AI)-1 transgenic peas, indicating that this inhibitor is highly effective in controlling this insect. By contrast, transgenic Laura and 'Dundale' expressing alpha-(AI)-2 did not affect pea weevil survival, but they did delay larval development. After 77 d of development, the head capsule size indicated that the larvae were still at the third instar stage in transgenic alpha-(AI)-2 peas, whereas adult bruchids had developed in the nontransgenic peas.
On the weight-bearing function of the medial coronoid process in dogs.
Breit, S; Künzel, W; Seiler, S
2006-02-01
The shape of and proportions between the surface areas of the medial coronoid process (MCP) and the fovea of the radial head were determined in 88 juvenile dogs and 146 adult dogs grouped as giant, large, mid-sized, chondrodystrophic, or small dogs. Thereby, the longitudinal (length) and transverse (width) extension of the MCP and fovea of the radial head have been measured. Original values were used to describe changes of the parameters attributed to growth. Normalized values (i.e. values expected in case of a width of the fovea of the radial head of 20 mm) were used to determine potential differences between constitutional types. All original values increased during growth (P < 0.05) except for the width and length of the MCP in chondrodystrophic and small breeds. Normalized values revealed a proportional decrease in width and length of the MCP during growth (P < 0.05) compared with the radial head. In adults, the normalized MCP was widest in giant dogs followed by large, mid-sized, small, and chondrodystrophic breeds. The MCP was also longest in giant dogs but shortest in large and chondrodystrophic dogs with those of large dogs being significantly (P < 0.05) shorter than those in giant, mid-sized and small dogs. Present results suggest that a deficiency in length-growth of the MCP--which has been present especially in large dogs--results in smaller humeral contact areas and decreased weight-bearing capacity of the MCP. Because loading forces acting on the MCP increase with body weight, the condition noted in large dogs might increase the risk of fragmentation of the MCP in these.
Parikh, Shital N; Bonnaig, Nicolas; Zbojniewicz, Andrew
2011-11-09
An 18-year-old woman presented with a history of recurrent glenohumeral dislocations involving her right dominant shoulder. Physical examination suggested physiologic hyperlaxity and anterior instability. Magnetic resonance arthrography demonstrated an anomalous intracapsular origin of the long head of the biceps tendon (LHBT), with normal-appearing LHBT in the intertubercular groove. Diagnostic arthroscopy confirmed the absence of the LHBT attachment on the superior labrum. Instead, the LHBT originated from the capsule of the shoulder joint. Diagnostic arthroscopy also revealed glenoid avulsion of the glenohumeral ligaments (GAGL) lesion as a tear in the anterior-inferior capsule near its insertion on the glenoid and labrum. An arthroscopic anterior capsulolabral repair was performed with rotator interval closure by imbrication of superior and middle glenohumeral ligaments. A retrospective review of the magnetic resonance arthrogram identified irregularity and interposition of contrast between the capsule and the anterior-inferior labrum that was reproduced in the abduction-external rotation view corresponding with the GAGL lesion seen at arthroscopy. At 12 months postoperatively, the patient demonstrated full range of motion and no signs of instability. This case report helps to raise awareness about 2 rare shoulder lesions: the anomalous origin of LHBT and the GAGL lesion. Diagnosing such lesions on preoperative magnetic resonance imaging may aid in operative planning and avoid unexpected intraoperative findings. Copyright 2011, SLACK Incorporated.
[Bilateral caudate head infarcts].
Kuriyama, N; Yamamoto, Y; Akiguchi, I; Oiwa, K; Nakajima, K
1997-11-01
We reported a 67-year-old woman with bilateral caudate head infarcts. She developed sudden mutism followed by abulia. She was admitted to our hospital 2 months after ictus for further examination. She showed prominent abulia and was inactive, slow and apathetic. Spontaneous activity and speech, immediate response to queries, spontaneous word recall and attention and persistence to complex programs were disturbed. Apparent motor disturbance, gait disturbance, motor aphasia, apraxia and remote memory disturbance were not identified. She seemed to be depressed but not sad. Brain CT and MRI revealed bilateral caudate head hemorrhagic infarcts including bilateral anterior internal capsules, in which the left lesion was more extensive than right one and involved the part of the left putamen. These infarct locations were thought to be supplied by the area around the medial striate artery including Heubner's arteries and the A1 perforator. Digital subtraction angiography showed asymptomatic right internal carotid artery occlusion. She bad had hypertension, diabetes mellitus and atrial fibrillation and also had a left atrium with a large diameter. The infarcts were thought to be caused by cardioembolic occlusion to the distal portion of the left internal carotid artery. Although some variations of vasculature at the anterior communicating artery might contribute to bilateral medial striate artery infarcts, we could not demonstrate such abnormalities by angiography. Bilateral caudate head infarcts involving the anterior internal capsule may cause prominent abulia. The patient did not improve by drug and rehabilitation therapy and died suddenly a year after discharge.
Abuhaimed, Abdullah; J Martin, Colin; Sankaralingam, Marimuthu; J Gentle, David; McJury, Mark
2014-11-07
The IEC has introduced a practical approach to overcome shortcomings of the CTDI100 for measurements on wide beams employed for cone beam (CBCT) scans. This study evaluated the efficiency of this approach (CTDIIEC) for different arrangements using Monte Carlo simulation techniques, and compared CTDIIEC to the efficiency of CTDI100 for CBCT. Monte Carlo EGSnrc/BEAMnrc and EGSnrc/DOSXYZnrc codes were used to simulate the kV imaging system mounted on a Varian TrueBeam linear accelerator. The Monte Carlo model was benchmarked against experimental measurements and good agreement shown. Standard PMMA head and body phantoms with lengths 150, 600, and 900 mm were simulated. Beam widths studied ranged from 20-300 mm, and four scanning protocols using two acquisition modes were utilized. The efficiency values were calculated at the centre (εc) and periphery (εp) of the phantoms and for the weighted CTDI (εw). The efficiency values for CTDI100 were approximately constant for beam widths 20-40 mm, where εc(CTDI100), εp(CTDI100), and εw(CTDI100) were 74.7 ± 0.6%, 84.6 ± 0.3%, and 80.9 ± 0.4%, for the head phantom and 59.7 ± 0.3%, 82.1 ± 0.3%, and 74.9 ± 0.3%, for the body phantom, respectively. When beam width increased beyond 40 mm, ε(CTDI100) values fell steadily reaching ~30% at a beam width of 300 mm. In contrast, the efficiency of the CTDIIEC was approximately constant over all beam widths, demonstrating its suitability for assessment of CBCT. εc(CTDIIEC), εp(CTDIIEC), and εw(CTDIIEC) were 76.1 ± 0.9%, 85.9 ± 1.0%, and 82.2 ± 0.9% for the head phantom and 60.6 ± 0.7%, 82.8 ± 0.8%, and 75.8 ± 0.7%, for the body phantom, respectively, within 2% of ε(CTDI100) values for narrower beam widths. CTDI100,w and CTDIIEC,w underestimate CTDI∞,w by ~55% and ~18% for the head phantom and by ~56% and ~24% for the body phantom, respectively, using a clinical beam width 198 mm. The CTDIIEC approach addresses the dependency of efficiency on beam width successfully and correction factors have been derived to allow calculation of CTDI∞.
Long-term hydrocephalus alters the cytoarchitecture of the adult subventricular zone
Campos-Ordoñez, Tania; Herranz-Pérez, Vicente; Chaichana, Kaisorn L.; Rincon-Torroella, Jordina; Rigamonti, Daniele; García-Verdugo, Jose M.; Quiñones-Hinojosa, Alfredo; Gonzalez-Perez, Oscar
2014-01-01
Hydrocephalus can develop secondarily to a disturbance in production, flow and/or absorption of cerebrospinal fluid. Experimental models of hydrocephalus, especially subacute and chronic hydrocephalus, are few and limited, and the effects of hydrocephalus on the subventricular zone are unclear. The aim of this study was to analyze the effects of long-term obstructive hydrocephalus on the subventricular zone, which is the neurogenic niche lining the lateral ventricles. We developed a new method to induce hydrocephalus by obstructing the aqueduct of Sylvius in the mouse brain, thus simulating aqueductal stenosis in humans. In 120-day-old rodents (n = 18 per group), the degree of ventricular dilatation and cellular composition of the subventricular zone were studied by immunofluorescence and transmission electron microscopy. In adult patients (age > 18 years), the sizes of the subventricular zone, corpus callosum, and internal capsule were analyzed by magnetic resonance images obtained from patients with and without aqueductal stenosis (n=25 per group). Mice with 60-day hydrocephalus had a reduced number of Ki67+ and doublecortin+ cells on immunofluorescence, as well as decreased number of neural progenitors and neuroblasts in the subventricular zone on electron microscopy analysis as compared to non-hydrocephalic mice. Remarkably, a number of extracellular matrix structures (fractones) contacting the ventricular lumen and blood vessels were also observed around the subventricular zone in mice with hydrocephalus. In humans, the widths of the subventricular zone, corpus callosum, and internal capsule in patients with aqueductal stenosis were significantly smaller than age and gender-matched patients without aqueductal stenosis. In summary, supratentorial hydrocephalus reduces the proliferation rate of neural progenitors and modifies the cytoarchitecture and extracellular matrix compounds of the subventricular zone. In humans, this similar process reduces the subventricular niche as well as the width of corpus callosum and internal capsule. PMID:24858805
Update on 2-D OMEGA Capsule Implosions
NASA Astrophysics Data System (ADS)
Bradley, Paul
2017-10-01
We have an upgraded laser energy deposition package in our AMR-Eulerian radiation-hydrodynamic code called RAGE. As part of our validation effort, we ran 2-D simulations for a series of OMEGA direct drive implosion capsules that have shell thickness ranging from 7.2 to 29.3 μm and different gas fills. These simulations include the effect of surface roughness, laser spot non-uniformity, the mounting stalk, and the glue spot. We examined the sensitivity of our simulated results to mesh resolution and mix model. Our simulated results compare well to the experimental yield, ion temperature, burn width, and x-ray size data. Work performed by Los Alamos National Laboratory under contract DE-AC52-06NA25396 for the National Nuclear Security Administration of the U.S. Department of Energy.
Morphometric analysis of instar variation in Tenebrio molitor (Coleoptera: Tenebrionidae)
USDA-ARS?s Scientific Manuscript database
Measurements of head capsule, mandible, metanotum, and body weight were done on larvae of Tenebrio molitor L. (Coleoptera: Tenebrionide) from the second to the last instar. Instar number varied from 14 to 18, but 15 or 16 instars were the most common. The value of dimensional measurements was evalua...
Variation in gypsy moth, with comparisons to other Lymantria spp.
Paul W. Schaefer
1991-01-01
Specimens of gypsy moth, Lymantria dispar (L.) sensu lato were displayed in museum trays. Many specimens were quarantine laboratory reared during the 1989 season to provide samples (wing venation, frozen adults, prepupal haemolymph, larval feeding behavior, egg mass hair color, head capsule coloration and larval development) for...
Atkinson, Stephen Douglas; Banner, Craig Randall
2017-01-01
Blue chub, Gila coerulea Girard, 1856 is a freshwater cyprinid fish native to inland drainages of western North America. It has not previously been recorded as a host of any myxosporean parasite (Cnidaria: Myxosporea), despite myxosporeans being cosmopolitan in freshwater and marine fishes worldwide and sympatric with this host. Herein, we describe a novel myxosporean from subcutaneous cysts in native blue chub from Klamath Lake, Oregon. Myxospores were consistent with genus Myxobolus, being obovoid but compressed in thickness, length 14.3 ± 0.4 (13-15) μm, width 9.7 ± 0.4 (9-10) μm, thickness 7.7 ± 0.3 (7-8) μm; two polar capsules ovoid slightly dissimilar in size, length 6.4 ± 0.4 (6-7) μm, width 3.8 ± 0.3 (3-4) μm, with four (3-5) turns of the polar filament (tubule); capsule openings apical, one in each valve cell. The small subunit ribosomal DNA sequence was up to 97 % similar to Myxobolus spp. from other cyprinids from North America and Europe. Given the novel host, unique myxospore morphometrics, and DNA sequence, we describe this as Myxobolus klamathellus n. sp.
Fjordbakk, C T; Chalmers, H J; Holcombe, S J; Strand, E
2013-11-01
The pathogenesis of dynamic bilateral laryngeal collapse (DLC) associated with poll flexion is unknown. Diagnosis is dependent upon exercise endoscopy while replicating the flexed head position harness racehorses experience during racing. To describe the effects of poll flexion on rostrocaudal laryngeal positioning and laryngeal lumen width in resting horses diagnosed with DLC compared to controls, and to establish diagnostic criteria for DLC by use of diagnostic imaging. Case-control study. Fifty harness racehorses were prospectively included in the study: 25 cases diagnosed with DLC by treadmill endoscopy and 25 controls in which treadmill endoscopy revealed no abnormal findings. Laryngeal radiography and ultrasonography were obtained in neutral and flexed head positions. Laryngeal positioning and laryngohyoid conformation were compared between the groups and head positions. Poll flexion induced a greater rostral advancement of the larynx in relation to the hyoid apparatus in resting harness racehorses affected with DLC compared to controls (P = 0.007). At the level of the vocal folds, poll flexion resulted in a smaller laryngeal lumen width in horses affected with DLC compared to controls (P = 0.04). Horses were significantly more likely to be affected with DLC when the thyrohyoid bone to thyroid cartilage distance was ≥12 mm in poll flexion (odds ratio 21.3, 95% confidence interval 3.65-124.8, P = 0.004) and when laryngeal lumen width at the level of the vocal folds was less in poll flexion than in the neutral head position (odds ratio 8.4; 95% confidence interval 1.6-44.1, P = 0.012). In DLC horses, poll flexion advanced the larynx more rostrally and resulted in a decreased airway lumen width compared to control horses. Laryngeal ultrasound and radiography may facilitate the diagnosis of DLC at rest. © 2013 EVJ Ltd.
Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.
Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan
2011-01-01
With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.
Apollo XIII Spacecraft - Splashdown - South Pacific Ocean
1970-04-17
S70-35652 (17 April 1970) --- The Apollo 13 spacecraft heads toward a splashdown in the South Pacific Ocean. The Apollo 13 Command Module splashed down in the South Pacific at 12:07:44 p.m., April 17, 1970. Note the capsule and its parachutes just visible against a gap in the dark clouds.
Jantzen, Troy M; Havenhand, Jon N
2003-06-01
Squid behavior is synonymous with distinctive body patterns, postures, and movements that constitute a complex visual communication system. These communications are particularly obvious during reproduction. They are important for sexual selection and have been identified as a potential means of species differentiation. Here we present a detailed account of copulation, mating, and egg deposition behaviors from in situ observations of the squid Sepioteuthis australis from South Australia. We identified four mating types from 85 separate mating attempts: "Male-upturned mating" (64% of mating attempts); "Sneaker mating" (33%); "Male-parallel" (2%); and "Head-to-head" (1%). Intervals between successive egg deposition behaviors were clearly bimodal, with modes at 2.5 s and 70.0 s. Ninety-three percent of egg capsules contained 3 or 4 eggs (mean = 3.54), and each egg cluster contained between 218 and 1922 egg capsules (mean = 893.9). The reproductive behavior of S. australis from South Australia was different from that described for other cephalopod species. More importantly, comparison between these results and those for other populations of S. australis suggests that behavior may differ from one population to another.
NASA Astrophysics Data System (ADS)
Wang, Y.; Finney, B.; Wooller, M. J.
2007-12-01
Several techniques are available to examine the isotopic composition of historic lake waters, providing data that can subsequently be used to examine environmental changes. Recently-developed techniques are the stable oxygen isotope analysis of subfossil chironomid (Diptera: Chironomidae) head capsules (mostly chitin) preserved in lake sediments and stable hydrogen isotope analyses directly on bulk sediments. An advantage of using δ18O of chironomids is that the chitinous chironomid headcapsules preserve well in lake sediments, retaining the stable oxygen isotope signature of the lake in which they lived. An advantage of δD analyses of bulk sediments is that a sediment core can be analyzed relatively easily and when the %C (total organic carbon) and %H profiles correlate the data can be used to infer past δD changes of the organics in the sediments. We present results from these analyses of a lake sediment core from Idavain Lake (58°46'N, 155°57'W, 223m above sea level) in southwest Alaska in concert with other paleolimnological proxies, including δ15N, δ13C, LOI, magnetic susceptibility, organic content and opal concentrations for a better understanding of paleolimnological changes since deglaciation for the region. Our preliminilary result shows that downcore shifts of δ18O analyzed from chironomid head capsules coincide well with LOI and pollen changes. The δD of sediments and TOM showed large magnitude changes and reflected the relative lake level changes during the record. This study aim to test the correlation between stable isotope analyese on chiornomid head capsules, lake water, and bulk sediments. In the addition, our study will add to the relatively small database of paleoenvironmental reconstructions from terrestrial sites in Southwest Alaska.
Delineation of sympatric morphotypes of lake trout in Lake Superior
Moore, Seth A.; Bronte, Charles R.
2001-01-01
Three morphotypes of lake trout Salvelinus namaycush are recognized in Lake Superior: lean, siscowet, and humper. Absolute morphotype assignment can be difficult. We used a size-free, whole-body morphometric analysis (truss protocol) to determine whether differences in body shape existed among lake trout morphotypes. Our results showed discrimination where traditional morphometric characters and meristic measurements failed to detect differences. Principal components analysis revealed some separation of all three morphotypes based on head and caudal peduncle shape, but it also indicated considerable overlap in score values. Humper lake trout have smaller caudal peduncle widths to head length and depth characters than do lean or siscowet lake trout. Lean lake trout had larger head measures to caudal widths, whereas siscowet had higher caudal peduncle to head measures. Backward stepwise discriminant function analysis retained two head measures, three midbody measures, and four caudal peduncle measures; correct classification rates when using these variables were 83% for leans, 80% for siscowets, and 83% for humpers, which suggests the measures we used for initial classification were consistent. Although clear ecological reasons for these differences are not readily apparent, patterns in misclassification rates may be consistent with evolutionary hypotheses for lake trout within the Laurentian Great Lakes.
Ring head recording on perpendicular media: Output spectra for CoCr and CoCr/NiFe media
NASA Astrophysics Data System (ADS)
Stubbs, D. P.; Whisler, J. W.; Moe, C. D.; Skorjanec, J.
1985-04-01
The recording density response for sputtered CoCr (thickness=0.5 μm) and CoCr/NiFe (t=0.25 μm/0.5 μm) as well as evaporated CoNi (t=0.12 μm) and Co surface-doped iron oxide particulate media has been measured by reading and writing with Mn-Zn ferrite heads (gap length=0.375 μm, track width=37 μm) in contact with the media. Measurements to 200 kfc/i (thousand flux changes per inch) show a gap null around 115 kfc/i. The data have been normalized by dividing out the head sensitivity to obtain the value of spacing plus transition width (d+a) for the various media. For the CoCr media this value varied from 0.075-0.088 μm; for CoNi, 0.100 μm, and for the particulate medium, 0.163 μm. In addition, testing with a larger gapped Mn-Zn ferrite head (g=2.43 μm) shows that the head fields are distorted by the soft magnetic underlayer in dual layer CoCr/NiFe samples when the gap length is large compared to the distance to the underlayer.
Martin, Colin J.; Sankaralingam, Marimuthu; Oomen, Kurian; Gentle, David J.
2015-01-01
Measurement of cumulative dose f(0,150) with a small ionization chamber within standard polymethyl methacrylate (PMMA) CT head and body phantoms, 150 mm in length, is a possible practical method for cone‐beam computed tomography (CBCT) dosimetry. This differs from evaluating cumulative dose under scatter equilibrium conditions within an infinitely long phantom f(0,∞), which is proposed by AAPM TG‐111 for CBCT dosimetry. The aim of this study was to investigate the feasibility of using f(0,150) to estimate values for f(0,∞) in long head and body phantoms made of PMMA, polyethylene (PE), and water, using beam qualities for tube potentials of 80−140 kV. The study also investigated the possibility of using 150 mm PE phantoms for assessment of f(0,∞) within long PE phantoms, the ICRU/AAPM phantom. The influence of scan parameters, composition, and length of the phantoms was investigated. The capability of f(0,150) to assess f(0,∞) has been defined as the efficiency and assessed in terms of the ratios ϵ(f(0,150)/f(0,∞)). The efficiencies were calculated using Monte Carlo simulations for an On‐Board Imager (OBI) system mounted on a TrueBeam linear accelerator. Head and body scanning protocols with beams of width 40−500 mm were used. Efficiencies ϵ(PMMA/PMMA) and ϵ(PE/PE) as a function of beam width exhibited three separate regions. For beam widths <150 mm, ϵ(PMMA/PMMA) and ϵ(PE/PE) values were greater than 90% for the head and body phantoms. The efficiency values then fell rapidly with increasing beam width before levelling off at 74% for ϵ(PMMA/PMMA) and 69% for ϵ(PE/PE) for a 500 mm beam width. The quantities ϵ(PMMA/PE) and ϵ(PMMA/Water) varied with beam width in a different manner. Values at the centers of the phantoms for narrow beams were lower and increased to a steady state for ∼100−150 mm wide beams, before declining with increasing the beam width, whereas values at the peripheries decreased steadily with beam width. Results for ϵ(PMMA/PMMA) were virtually independent of tube potential, but there was more variation for ϵ(PMMA/PE) and ϵ(PMMA/Water). f(0,150) underestimated f(0,∞) for beam widths used for CBCT scans, thus it is necessary to use long phantoms, or apply conversion factors (Cfs) to measurements with standard PMMA CT phantoms. The efficiency values have been used to derive (Cfs) to allow evaluation of f(0,∞) from measurements of f(0,150). The (Cfs) only showed a weak dependence on scan parameters and scanner type, and so may be suitable for general application. PACS number: 87.55.K‐, 87.57.Q‐, 87.57.uq. PMID:26699590
NASA Technical Reports Server (NTRS)
Gibbons, D. F.
1977-01-01
The objectives in this report were to use the ion beam sputtering technique to produce surface textures on polymers, metals, and ceramics. The morphology of the texture was altered by varying both the width and depth of the square pits which were formed by ion beam erosion. The width of the ribs separating the pits were defined by the mask used to produce the texture. The area of the surface containing pits varies as the width was changed. The biological parameters used to evaluate the biological response to the texture were: (1) fibrous capsule and inflammatory response in subcutaneous soft tissue; (2) strength of the mechanical attachment of the textured surface by the soft tissue; and (3) morphology of the epidermal layer interfacing the textured surface of percutaneous connectors. Because the sputter yield on teflon ribs was approximately an order of magnitude larger than any other material the majority of the measurements presented in the report were obtained with teflon.
Varea-Sánchez, María; Gómez Montoto, Laura; Tourmente, Maximiliano; Roldan, Eduardo R. S.
2014-01-01
Interspecific comparative studies have shown that, in most taxa, postcopulatory sexual selection (PCSS) in the form of sperm competition drives the evolution of longer and faster swimming sperm. Work on passserine birds has revealed that PCSS also reduces variation in sperm size between males at the intraspecific level. However, the influence of PCSS upon intra-male sperm size diversity is poorly understood, since the few studies carried out to date in birds have yielded contradictory results. In mammals, PCSS increases sperm size but there is little information on the effects of this selective force on variations in sperm size and shape. Here, we test whether sperm competition associates with a reduction in the degree of variation of sperm dimensions in rodents. We found that as sperm competition levels increase males produce sperm that are more similar in both the size of the head and the size of the flagellum. On the other hand, whereas with increasing levels of sperm competition there is less variation in head length in relation to head width (ratio CV head length/CV head width), there is no relation between variation in head and flagellum sizes (ratio CV head length/CV flagellum length). Thus, it appears that, in addition to a selection for longer sperm, sperm competition may select more uniform sperm heads and flagella, which together may enhance swimming velocity. Overall, sperm competition seems to drive sperm components towards an optimum design that may affect sperm performance which, in turn, will be crucial for successful fertilization. PMID:25243923
Andrea Brunelle; Gerald E. Rehfeldt; Barbara Bentz; A. Steven Munson
2008-01-01
Paleoecological reconstructions from two lakes in the U.S. northern Rocky Mountain region of Idaho and Montana revealed the presence of bark beetle elytra and head capsules (cf. Dendroctonus spp., most likely D. ponderosae, mountain pine beetle). Occurrence of these macrofossils during the period of time associated with the 1920/...
A high-energy-density, high-Mach number single jet experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hansen, J. F.; Dittrich, T. R.; Elliott, J. B.
2011-08-15
A high-energy-density, x-ray-driven, high-Mach number (M{>=} 17) single jet experiment shows constant propagation speeds of the jet and its bowshock into the late time regime. The jet assumes a characteristic mushroom shape with a stalk and a head. The width of the head and the bowshock also grow linearly in time. The width of the stalk decreases exponentially toward an asymptotic value. In late time images, the stalk kinks and develops a filamentary nature, which is similar to experiments with applied magnetic fields. Numerical simulations match the experiment reasonably well, but ''exterior'' details of the laser target must be includedmore » to obtain a match at late times.« less
Method of simultaneous measurement of two direction force and temperature using FBG sensor head.
Kisała, Piotr; Cięszczyk, Sławomir
2015-04-01
This paper presents a method for measuring two components of bending force and temperature using one sensor head. Indirect inference based on the spectra of two fiber Bragg gratings (FBGs) placed on a cantilever beam is used. The method was developed during work on the inverse problem of determining a nonuniform stress distribution based on FBG spectra. A gradient in the FBG stress profile results in a characteristic shape of its reflective spectrum. The simultaneous measurements of force and temperature were possible through the use of an appropriate layout of the sensor head. The spectral characteristics of the sensor's gratings do not retain full symmetry, which is due to the geometry of the sensor's head and the related difference in the distribution of the axial stress of the gratings. In the proposed approach, the change in width of the sum of the normalized transmission spectra was used to determine the value of the applied force. In the presented method, an increase in the sensitivity of this change to the force is obtained relative to the other known systems. A change in the spectral width was observed for an increase in bending forces from 0 to 150 N. The sensitivity coefficient of the spectral width to force, defined as the ratio of the change of the spectral half-width to the change in force was 2.6e-3 nm/N for the first grating and 1.2e-3 nm/N for the second grating. However, the sensitivity of the whole sensor system was 5.8e-3 nm/N, which is greater than the sum of the sensitivities of the individual gratings. For the purpose of this work, a station with a thermal chamber has been designed with a bracket on which fiber optic transducers have been mounted for use in further measurements. The sensor head in this experiment is considered to be a universal device with potential applications in other types of optical sensors, and it can be treated as a module for development through its multiplication on a single optical fiber.
Panic and fear induced by deep brain stimulation.
Shapira, N A; Okun, M S; Wint, D; Foote, K D; Byars, J A; Bowers, D; Springer, U S; Lang, P J; Greenberg, B D; Haber, S N; Goodman, W K
2006-03-01
Mood, cognitive, and behavioural changes have been reported with deep brain stimulation (DBS) in the thalamus, globus pallidus interna, and anterior limb of the internal capsule/nucleus accumbens region. To investigate panic and fear resulting from DBS. Intraoperative DBS in the region of the right and then left anterior limb of the internal capsule and nucleus accumbens region was undertaken to treat a 52 year old man with treatment refractory obsessive-compulsive disorder (OCD). Mood, anxiety, OCD, alertness, heart rate, and subjective feelings were recorded during intraoperative test stimulation and at follow up programming sessions. DBS at the distal (0) contact (cathode 0-, anode 2+, pulse width 210 ms, rate 135 Hz, at 6 volts) elicited a panic attack (only seen at the (0) contact). The patient felt flushed, hot, fearful, and described himself as having a "panic attack." His heart rate increased from 53 to 111. The effect (present with either device) was witnessed immediately after turning the device on, and abruptly ceased in the off condition DBS of the anterior limb of the internal capsule and nucleus accumbens region caused severe "panic." This response may result from activation of limbic and autonomic networks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ho, Jong-Han, E-mail: jonghanho@gmail.com; Hagler, Shane; Lujano, Carrie
Cancer is a global health issue that disproportionately kills based on stage of disease, cellular pathology, and genetics, to name a few. Another variable to consider in this ongoing fight is treatment machine complexity that leads to elevated development and purchasing cost, leading to a reduced use. Reducing the complexity (in hopes of lowering costs) would benefit underdeveloped, low- and middle-income countries by introducing newer treatment technology, as their currently accepted standards do not meet standards of more advanced, developed countries. In this study, unilateral head and neck (H&N), and prostate cases using volumetric modulated arc therapy (VMAT) were testedmore » with multiple segment widths of 5, 10, 15, and 20 mm to create treatable plans. Pinnacle 9.10v was used for planning purposes. A total of 12 cases were planned with varying multileaf collimator (MLC) widths. Treatment plans were evaluated retrospectively. Results show that altering the MLC widths from 5 through 20 mm produces both comparable and treatable plans up to 99% and 98% target coverage for H&N and prostate, respectively, albeit clinically significant hot spots were shown to increase with increasing segment width. Furthermore, the results show that increasing widths can produce comparable treatment plans as measured against our current Food and Drug Administration (FDA)–approved treatment devices—leading to an increase in treatment efficacy in economically underdeveloped countries.« less
Mathews, Patrick D; Maia, Antônio A M; Adriano, Edson A
2016-09-01
A new species of myxozoan, Henneguya melini sp. n. (Myxosporea: Myxobolidae), was described based on morphologic and ultrastructural features. This is a parasite of the ornamental freshwater fish C. melini from the Rio Negro, and it was found in five of 30 (16.7 %) C. melini examined. The parasite was found in the gill filaments, and the plasmodia had form of round to ellipsoid, with mature and immature spores inside them. The average spore body was 15.5 ± 0.2 μm in length, 4.7 ± 0.1 μm in width, and the tail measured 25.3 ± 0.1 μm in length. The spores showed typical features of the genus Henneguya, with two valves of equal size and two symmetrical polar capsules of 4.8 ± 0.7 μm in length and 1.7 ± 0.3 μm in width. Each polar capsule had a polar filament with five to six turns. Based on morphology (morphologic and ultrastructural data) of the plasmodia and spores and the fact that this is the first report of a Henneguya species in a fish species of the genus Corydoras, it was considered a new myxozoan species.
NASA Technical Reports Server (NTRS)
Gay, Robert S.; Bihari, Brian D.
2008-01-01
Due to mass constraints, the Orion Command Module landing attention system requires that the capsule be oriented in a specific direction with respect to the horizontal surface-relative velocity (Heading) at touchdown in order to keep crew and vehicle loads within specifications. These constraints apply to both land and water landings. In fact, water landings are even more constrained with the addition of impact angle requirements necessary to slice through the water. There are two primary challenges with achieving this touchdown orientation: 1. Navigation knowledge of velocity (needed to determine Heading) with and without GPS, including the effects of the Heading angle itself becoming undefined as horizontal velocity decreases, and 2. Controlling to the desired orientation in the presences of chute torque and wind gusts that may change the Heading just prior to touchdown. This paper will discuss the design and performance of the current Orion navigation and control system used to achieve the desired orientation at touchdown.
Grose, A W; Gardner, M J; Sussmann, P S; Helfet, D L; Lorich, D G
2008-10-01
The inferior gluteal artery is described in standard anatomy textbooks as contributing to the blood supply of the hip through an anastomosis with the medial femoral circumflex artery. The site(s) of the anastomosis has not been described previously. We undertook an injection study to define the anastomotic connections between these two arteries and to determine whether the inferior gluteal artery could supply the lateral epiphyseal arteries alone. From eight fresh-frozen cadaver pelvic specimens we were able to inject the vessels in 14 hips with latex moulding compound through either the medial femoral circumflex artery or the inferior gluteal artery. Injected vessels around the hip were then carefully exposed and documented photographically. In seven of the eight specimens a clear anastomosis was shown between the two arteries adjacent to the tendon of obturator externus. The terminal vessel arising from this anastomosis was noted to pass directly beneath the posterior capsule of the hip before ascending the superior aspect of the femoral neck and terminating in the lateral epiphyseal vessels. At no point was the terminal vessel found between the capsule and the conjoined tendon. The medial femoral circumflex artery receives a direct supply from the inferior gluteal artery immediately before passing beneath the capsule of the hip. Detailed knowledge of this anatomy may help to explain the development of avascular necrosis after hip trauma, as well as to allow additional safe surgical exposure of the femoral neck and head.
Konuma, Junji; Yamamoto, Satoshi; Sota, Teiji
2014-12-01
The snail-feeding carabid beetle Damaster blaptoides exhibits diverse head and thorax morphologies, and these morphotypes are linked with two alternative feeding behaviours. Stout-shaped beetles feed on snails by crushing the shells, whereas slender-shaped beetles consume snails by inserting their heads into the shells. A trade-off exists between these feeding strategies. Because intermediate-shaped beetles are less proficient in these two behaviours, stout-slender morphological divergence occurs between related species feeding on land snails. To examine the genetic basis of these morphotypes, we conducted morphological analyses and quantitative trait locus (QTL) mapping using backcross offspring between the stout and slender subspecies. The morphological analyses showed that the width and length of the beetle body parts were correlated with each other; in particular, the head width (HW) and thorax length (TL) were strongly negatively correlated. QTL mapping showed that QTLs for HW and TL are located in close proximity to one another on the longest linkage group and that they have positive and negative additive genetic effects. Our results suggest that the adaptive phenotypic sets of a wide head and short thorax and a narrow head and long thorax are based on the closeness of these QTLs. Morphological integration between the head and thorax may play an important role in the adaptive divergence of these beetles. © 2014 John Wiley & Sons Ltd.
Parkash, Chander; Kumar, Sandeep; Singh, Rajender; Kumar, Ajay; Kumar, Satish; Dey, Shyam Sundar; Bhatia, Reeta; Kumar, Raj
2018-01-01
A comprehensive study on characterization and genetic diversity analysis was carried out in 16 'Ogura'-based 'CMS' lines of cabbage using 14 agro-morphological traits and 29 SSR markers. Agro-morphological characterization depicted considerable variations for different horticultural traits studied. The genotype, ZHA-2, performed better for most of the economically important quantitative traits. Further, gross head weight (0.76), head length (0.60) and head width (0.83) revealed significant positive correlation with net head weight. Dendrogram based on 10 quantitative traits exhibited considerable diversity among different CMS lines and principle component analysis (PCA) indicated that net and gross head weight, and head length and width are the main components of divergence between 16 CMS lines of cabbage. In molecular study, a total of 58 alleles were amplified by 29 SSR primers, averaging to 2.0 alleles in each locus. High mean values of Shannon's Information index (0.62), expected (0.45) and observed (0.32) heterozygosity and polymorphic information content (0.35) depicted substantial polymorphism. Dendrogram based on Jaccard's similarity coefficient constructed two major groups and eight sub-groups, which revealed substantial diversity among different CMS lines. In overall, based on agro-morphological and molecular studies genotype RRMA, ZHA-2 and RCA were found most divergent. Hence, they have immense potential in future breeding programs for the high-yielding hybrid development in cabbage.
Sexual dimorphism in head size of the Mediterranean gecko Hemidactylus turcicus (Sauria: Gekkonidae)
Daniel Saenz; Richard N. Conner
1996-01-01
Comparisons were made between 53 female and 67 male Mediterranean geckos (Hemidactylus turcicus) collected from the campus of Stephen F. Austin State University in Nacogdoches, Texas. Head dimensions (length, depth and width) and weight of adult males and females were compared with analysis of covariance using snout-vent-length as a covariate. Males were...
NASA Astrophysics Data System (ADS)
Ye, Lingtong; Lu, Mingmiao; Quan, Keyan; Li, Wenxiang; Zou, Hong; Wu, Shangong; Wang, Jiangyong; Wang, Guitang
2017-05-01
The mass mortality of pond-reared scattered mirror carp, Cyprinus carpio, caused by Thelohanellus kitauei, occurred at fish farms in Sichuan Province, southwest China. Morphological and molecular analyses were supplemented with histological evaluation of infected tissues to better understand the route of infection and the pathological effects of T. kitauei on the fish host. The intestine of the diseased host was full of large cysts of the myxosporean. The cysts range from 2 cm to 3.6 cm in diameter. Histopathology indicated that T. kitaue i first invaded the submucosa of the host intestine and then moved into the mucosa layers with the development of their spores, finally entering into the enteric cavity of the hosts after the disruption of mucosa layers. The pyriform spores of T. kitauei were surrounded by the transparent spore sheath, measuring 25.98 μm±0.95 μm in body length, 8.72 μm±0.51 μm in body width, and 7.86 μm±0.26 μm in body thickness. The single polar capsule was pyriform, measuring 14.73 μm±0.92 μm in length and 6.82 μm±0.45 μm in width, with eight to 10 turns of filament coils winding inside. Phylogenetic analysis based on the 18S small-subunit ribosomal DNA sequences indicated that minimal genetic differences were present between T. kitauei samples from South Korea and from China. Close affinity was found between the genus Thelohanellus and Myxobolus. Additionally, two polar capsule nuclei were found at the anterior end of the single polar capsule in spores of T. kitauei stained with hematoxylin and eosin, which suggested the separation of the genus Thelohanellus from Myxobolus.
Long-term hydrocephalus alters the cytoarchitecture of the adult subventricular zone.
Campos-Ordoñez, Tania; Herranz-Pérez, Vicente; Chaichana, Kaisorn L; Rincon-Torroella, Jordina; Rigamonti, Daniele; García-Verdugo, Jose M; Quiñones-Hinojosa, Alfredo; Gonzalez-Perez, Oscar
2014-11-01
Hydrocephalus can develop secondarily to a disturbance in production, flow and/or absorption of cerebrospinal fluid. Experimental models of hydrocephalus, especially subacute and chronic hydrocephalus, are few and limited, and the effects of hydrocephalus on the subventricular zone are unclear. The aim of this study was to analyze the effects of long-term obstructive hydrocephalus on the subventricular zone, which is the neurogenic niche lining the lateral ventricles. We developed a new method to induce hydrocephalus by obstructing the aqueduct of Sylvius in the mouse brain, thus simulating aqueductal stenosis in humans. In 120-day-old rodents (n=18 per group), the degree of ventricular dilatation and cellular composition of the subventricular zone were studied by immunofluorescence and transmission electron microscopy. In adult patients (age>18years), the sizes of the subventricular zone, corpus callosum, and internal capsule were analyzed by magnetic resonance images obtained from patients with and without aqueductal stenosis (n=25 per group). Mice with 60-day hydrocephalus had a reduced number of Ki67+ and doublecortin+cells on immunofluorescence, as well as decreased number of neural progenitors and neuroblasts in the subventricular zone on electron microscopy analysis as compared to non-hydrocephalic mice. Remarkably, a number of extracellular matrix structures (fractones) contacting the ventricular lumen and blood vessels were also observed around the subventricular zone in mice with hydrocephalus. In humans, the widths of the subventricular zone, corpus callosum, and internal capsule in patients with aqueductal stenosis were significantly smaller than age and gender-matched patients without aqueductal stenosis. In summary, supratentorial hydrocephalus reduces the proliferation rate of neural progenitors and modifies the cytoarchitecture and extracellular matrix compounds of the subventricular zone. In humans, this similar process reduces the subventricular niche as well as the width of corpus callosum and internal capsule. Copyright © 2014 Elsevier Inc. All rights reserved.
Eiras, J C; D'Souza, J
2004-09-01
Two species of Myxobolus are reported from the gills of Mugil cephalus collected at Goa, India: M. goensis n. sp. and M. parvus Shulman, 1962. Myxobolus goensis n. sp. forms digitiform or rounded plasmodia between the gill rakers. Their spores are oval in frontal view, with tapered anterior extremity, and lemon-shaped in lateral view, measuring 9.7 (9.5-10.5) microm in length, 6.6 (6-7.5) microm in width, and 5.2 (5-6) microm in thickness. The polar capsules are pyriform and unequal in size. The larger ones are 5.3 (4.5-6) microm long and 2.4 (2-3) microm wide; the smaller ones are 2.4 (2-3) microm long and 1.8 (1.5-2) microm wide. The polar filament forms five turns aligned perpendicularly to the longitudinal axis of the larger polar capsules. Within the smaller polar capsules the polar filament is difficult to observe and, apparently, forms three coils. The spores are distinctly different from other Myxobolus species infecting M. cephalus and other Mugil spp. Furthermore, the present material is also different from 204 Myxobolus species presenting differently sized polar capsules, representing nearly all the known species with this characteristic. The fact that only the M. cephalus specimens were infected among a sample of 206 fish specimens, comprising 27 different species, strongly suggests that this parasite is specific to M. cephalus.
Amado, Sávio; Silveira, Andrea Kill; Vieira, Flávio Dias; Traversa, Donato
2014-01-01
The present paper describes the morphological modifications occurring during the larval development of Habronema muscae (Nematoda: Habronematidae) in Musca domestica (Diptera: Muscidae), along with the reactions caused by parasitism and the migration route of the nematodes inside the flies. Houseflies were reared on faeces of a H. muscae-infected horse, then dissected and processed by histology. The experimental part of the study was performed in 1996 in the Parasitological Experimental Station W.O. Neitz, Federal Rural University of Rio de Janeiro, Seropédica, Rio de Janeiro State, Brazil. Three different larval stages of H. muscae were recovered, measured and described. The encapsulation of larval nematodes was found in the third larval instar (L3) of M. domestica and cryptocephalic pupa. The mature capsules were observed in dipteran L3, pupae and mainly adults. In 1day-old or more M. domestica adults an active rupturing of capsules by H. muscae L3 and the migration to the head through the circulatory system and insect hemocoel were observed. Infective H. muscae L3s remained exclusively in the head of adult 5days-old or more M. domestica. Copyright © 2013 Elsevier Inc. All rights reserved.
Immature stages of the Australian flower-loving fly Apiocera striativentris (Diptera: Apioceridae).
Ferguson, David J; Yeates, David K
2018-02-26
The Apioceridae (Diptera) are relatively large asiloid flies with just over 140 described species worldwide. They are closely related to both Mydidae and Asilidae, and most species are found in Australia and North America, however a handful are found in both southern Africa and southern South America. The immature stages of only one species is known, the Australian beach dune inhabiting species Apiocera maritima Hardy. Like most asiloid larvae, apiocerid larvae are assumed to be predators of other soft-bodied invertebrates in the soil. Anatomically the larvae and pupae are similar to those of closely related families. The larvae are elongate, cream-coloured, subcylindrical and with a small, well-sclerotised head capsule. The pupa has a number of robust processes and spines on the head capsule and rows of distinctive bristles on the abdominal tergites. These spines and bristles are used by the pupa to drill upwards out of the soil prior to adult emergence. Here we describe the late instar larva and pupa of the Australian species A. striativentris Paramonov and compare them to the larva and pupa of the previously described species. Apiocerid larvae have distinctive, rounded abdominal segments 2-5 that may be diagnostic for the family.
Small-bowel capsule endoscopy: A ten-point contemporary review
Koulaouzidis, Anastasios; Rondonotti, Emanuele; Karargyris, Alexandros
2013-01-01
The introduction of capsule endoscopy (CE) in clinical practice increased the interest for the study of the small-bowel. Consequently, in about 10 years, an impressive quantity of literature on indications, diagnostic yield (DY), safety profile and technical evolution of CE has been published as well as several reviews. At present time, there are 5 small-bowel capsule enteroscopy (SBCE) models in the worldwide market. Head-to-head trials have showed in the great majority of studies comparable results in terms of DY, image quality and completion rate. CE meta-analyses formed the basis of national/international guidelines; these guidelines place CE in a prime position for the diagnostic work-up of patients with obscure gastrointestinal bleeding, known and/or suspected Crohn’s disease and possible small-bowel neoplasia. A 2-L polyethylene glycol-based purge, administered the day before the procedure, is the most widely practiced preparation regimen. Whether this regimen can be further improved (i.e., by further decreasing its volume, changing the timing of administration, coupling it with prokinetics and/or other factors) or if it can really affect the DY, is still under discussion. Faecal calprotectin has been used in SBCE studies in two settings: in patients taking non-steroidal anti-inflammatory drugs, to evaluate the type and extent of mucosal damage and, more importantly from a clinical point of view, in patients with known or suspected Crohn’s disease for assessment of inflammation activity. Although there is still a lot of debate around the exact reasons of SBCE poor performance in various small-bowel segments, it is worth to remember that the capsule progress is non-steerable, hence more rapid in the proximal than in lower segments of the small-bowel. Capsule aspiration, a relatively unexpected complication, has been reported with increasing frequency. This is probably related with the increase in the mean age of patients undergoing CE. CE video review is a time-consuming procedure. Therefore, several attempts have been made to develop technical software features, in order to make CE video analysis easier and shorter (without jeopardizing its accuracy). Suspected Blood Indicator, QuickView and Fujinon Intelligent Chromo Endoscopy are some of the software tools that have been checked in various clinical studies to date. PMID:23840112
De Meyer, Jens; Van Wassenbergh, Sam; Bouilliart, Mathias; Dhaene, Jelle; Adriaens, Dominique
2018-03-01
The presence of two phenotypes in a single species is a widespread phenomenon, also observed in European eel (Anguilla anguilla). This dimorphism has been related to dietary differences in the subadult elver and yellow eel stages, with broad-heads generally feeding on harder and/or larger-bodied prey items than narrow-heads. Nevertheless, both broad- and narrow-headed phenotypes can already be found among glass eels, the stage preceding the elver eel stage. As these glass eels are considered nonfeeding, we investigate here to what degree the observed variation in head width is reflected in variation in the musculoskeletal feeding system, as well as whether this reflects the same variation observed in the older, dimorphic yellow eels. Additionally, we investigate whether musculoskeletal differences between broad- and narrow-headed glass eels have implications on their feeding performance and could thus impact prey preference when eels start feeding. Therefore, we compared the cranial musculoskeletal system of five broad- and narrow-headed glass eels using 3D-reconstructions and simulated the glass eel's bite force using the data of the muscle reconstructions. We found that the variation in the musculoskeletal system of glass eels indeed reflects that of the yellow eels. Broader heads were related to larger jaw muscles, responsible for mouth closure. Accordingly, broad-heads could generate higher bite forces than narrow-headed glass eels. In addition, broader heads were associated with higher coronoid processes and shorter hyomandibulae, beneficial for dealing with higher mechanical loadings and consequently, harder prey. We, thus, show that head width variation in glass eels is related to musculoskeletal differences which, in turn, can affect feeding performance. As such, differences in prey preference can already take place the moment the eels start feeding, potentially leading to the dimorphism observed in the elver and yellow eel stage. © 2017 Wiley Periodicals, Inc.
Variations of the attachment of the superior head of human lateral pterygoid muscle.
Antonopoulou, Maria; Iatrou, Ioannis; Paraschos, Alexandros; Anagnostopoulou, Sophia
2013-09-01
The superior head of the lateral pterygoid muscle (LPM), is closely related to the temporomandibular joint (TMJ) and plays a role in the aetiology of temporomandibular disorders. Increased activity of this muscle has been implicated in the anterior displacement of the TMJ disc. However, there is uncertainty about the manner of the LPM attachment to the disc-condyle complex. The aim of this study was to investigate the exact anatomy of the attachment of the superior head of the LPM (SLPM) to the disc-condyle complex of the TMJ. Thirty-six TMJs were examined - both sides of 18 Greek cadavers (eight males and 10 females, mean age 79.6 years). Examination of the attachment of the SLPM was undertaken viewed under the dissecting microscope. Variation in the attachment of the SLPM was categorized into three types: in type I, the SLPM inserted into the condyle and the disc-capsule complex (55.5%). In type II, the SLPM only inserted into the condyle (27.8%). In type III, the SLPM inserted purely into the disc-capsule complex (16.7%). This study demonstrates that there are three different attachment types of the SLPM to the disc-condyle complex. The type III variation could be involved in the TMJ pathology. The knowledge of the variations of the SLPM attachment could be useful for precise surgical and pharmaceutical approaches. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Design and control of 2-axis tilting actuator for endoscope using ionic polymer metal composites
NASA Astrophysics Data System (ADS)
Kim, Sung-Joo; Kim, Chul-Jin; Park, No-Cheol; Yang, Hyun-Seok; Park, Young-Pil
2009-03-01
In field of endoscopy, in order to overcome limitation in conventional endoscopy, capsule endoscope has been developed and has been recently applied in medical field in hospital. However, since capsule endoscope moves passively through GI tract by peristalsis, it is not able to control direction of head including camera. It is possible to miss symptoms of disease. Therefore, in this thesis, 2-Axis Tilting Actuator for Endoscope, based on Ionic Polymer Metal Composites (IPMC), is presented. In order to apply to capsule endoscope, the actuator material should satisfy a size, low energy consumption and low working voltage. Since IPMC is emerging material that exhibits a large bending deflection at low voltage, consume low energy and it can be fabricated in any size or any shape, IPMC are selected as an actuator. The system tilts camera module of endoscope to reduce invisible area of the intestines and a goal of tilting angle is selected to be an angle of 5 degrees for each axis. In order to control tiling angle, LQR controller and the full order observer is designed.
Tongue Abnormalities Are Associated to a Maternal Folic Acid Deficient Diet in Mice
Maldonado, Estela; López-Gordillo, Yamila; Varela-Moreiras, Gregorio; Martínez-Álvarez, Concepción; Pérez-Miguelsanz, Juliana
2017-01-01
It is widely accepted that maternal folic acid (FA) deficiency during pregnancy is a risk factor for abnormal development. The tongue, with multiple genes working together in a coordinated cascade in time and place, has emerged as a target organ for testing the effect of FA during development. A FA-deficient (FAD) diet was administered to eight-week-old C57/BL/6J mouse females for 2–16 weeks. Pregnant dams were sacrificed at gestational day 17 (E17). The tongues and heads of 15 control and 210 experimental fetuses were studied. In the tongues, the maximum width, base width, height and area were compared with width, height and area of the head. All measurements decreased from 10% to 38% with increasing number of weeks on maternal FAD diet. Decreased head and tongue areas showed a harmonic reduction (Spearman nonparametric correlation, Rho = 0.802) with respect to weeks on a maternal FAD diet. Tongue congenital abnormalities showed a 10.9% prevalence, divided in aglossia (3.3%) and microglossia (7.6%), always accompanied by agnathia (5.6%) or micrognathia (5.2%). This is the first time that tongue alterations have been related experimentally to maternal FAD diet in mice. We propose that the tongue should be included in the list of FA-sensitive birth defect organs due to its relevance in several key food and nutrition processes. PMID:29283374
Tongue Abnormalities Are Associated to a Maternal Folic Acid Deficient Diet in Mice.
Maldonado, Estela; López-Gordillo, Yamila; Partearroyo, Teresa; Varela-Moreiras, Gregorio; Martínez-Álvarez, Concepción; Pérez-Miguelsanz, Juliana
2017-12-28
It is widely accepted that maternal folic acid (FA) deficiency during pregnancy is a risk factor for abnormal development. The tongue, with multiple genes working together in a coordinated cascade in time and place, has emerged as a target organ for testing the effect of FA during development. A FA-deficient (FAD) diet was administered to eight-week-old C57/BL/6J mouse females for 2-16 weeks. Pregnant dams were sacrificed at gestational day 17 (E17). The tongues and heads of 15 control and 210 experimental fetuses were studied. In the tongues, the maximum width, base width, height and area were compared with width, height and area of the head. All measurements decreased from 10% to 38% with increasing number of weeks on maternal FAD diet. Decreased head and tongue areas showed a harmonic reduction (Spearman nonparametric correlation, Rho = 0.802) with respect to weeks on a maternal FAD diet. Tongue congenital abnormalities showed a 10.9% prevalence, divided in aglossia (3.3%) and microglossia (7.6%), always accompanied by agnathia (5.6%) or micrognathia (5.2%). This is the first time that tongue alterations have been related experimentally to maternal FAD diet in mice. We propose that the tongue should be included in the list of FA-sensitive birth defect organs due to its relevance in several key food and nutrition processes.
Pogorzelski, J; Braun, S; Imhoff, A B; Beitzel, K
2016-12-01
Treatment of posterior shoulder instability with increased retroversion of the glenoid using open-wedge osteotomy of the glenoid neck stabilized with an autologous bone block. Symptomatic, atraumatic posterior shoulder instability with increased retroversion (>20°) of the glenoid and previously failed conservative or surgical treatment. General contraindications against surgery. Relative contraindications: osteoporosis, nicotine abuse, or suspected patient noncompliance. Posterior approach with a 7 cm long incision starting medial of the posterolateral corner of the acromion heading to the posterior axillary fold and subsequent preparation of the deltoid muscle and the infraspinatus muscle. The posterior glenohumeral capsule is incised by performing a capsular T‑shift. The osteotomy is performed intracapsulary medial to the genoid rim. The wedge bone graft, harvested from spina scapulae or iliac spine, is placed "press fit" in position. Additional fixation of the graft is not necessary if the anterior cortex is intact. For reinforcing the posterior capsule, a posterior capsule shift should be performed. Insertion of extracapsular wound drainage. Successive wound closure. Postoperative immobilization in a 0° shoulder orthesis for 6 weeks; avoidance of horizontal abduction for 8 weeks. After removing the wound drainage, start of limited active-assisted range of motion. Over-head sports after 6 months. From 2009-2015, 6 posterior open wedge glenoid osteotomies were performed. Postoperative retroversion of the glenoid was 11.2 ± 9.4° compared to 26.0 ± 8.6° before surgery. Of 6 shoulders, 2 showed postoperative signs of persistent posterior instability; the other 4 shoulders were free of complaints. No revision surgery was needed.
Durham, Zachary L.; Hawkins, Jordan L.; Durham, Paul L.
2016-01-01
Objective Elevated levels of tumor necrosis factor-alpha (TNF-α) in the capsule of the temporomandibular joint (TMJ) are implicated in the underlying pathology of temporomandibular disorders (TMD). TMD are a group of conditions that result in pain in the TMJ and/or muscles of mastication, and are associated with significant social and economic burdens. The goal of this study was to investigate the effect of elevated TNF-α levels in the TMJ capsule on nocifensive behavioral response to mechanical stimulation of trigeminal neurons and regulation of cytokines within the trigeminal ganglion. Design Male Sprague-Dawley rats were injected bilaterally in the TMJ capsule with TNF-α and changes in nocifensive head withdrawal responses to mechanical stimulation of cutaneous tissue directly over the capsule was determined using von Frey filaments. Cytokine levels in trigeminal ganglia were determined by protein array analysis at several time points post injection and correlated to nocifensive behavior. Results TNF-α caused a significant increase in the average number of nocifensive responses when compared to naive and vehicle treated animals 2 hours post injection, but levels returned to control levels at 24 hours. Based on array analysis, the levels of eight cytokines were significantly elevated above vehicle control levels at 2 hours following TNF-α injection, but all eight had returned to the vehicle control levels after 24 hours. Conclusions Our findings provide evidence that elevated levels of TNF-α in the joint capsule, which is reported to occur in TMD, promotes nociception in trigeminal ganglia neurons via a mechanism that temporally correlates with differential regulation of several cytokines. PMID:27836101
Domain wall structure and interactions in 50 nm wide Cobalt nanowires
NASA Astrophysics Data System (ADS)
Tu, Kun-Hua; Ojha, Shuchi; Ross, Caroline A.
2018-05-01
Arrays of cobalt nanowires with widths of 50 nm, thickness of 5 and 20 nm and periodicity of 70 nm were fabricated by pattern transfer from a self-assembled block copolymer film. Transverse domain walls (DWs) were imaged by magnetic force microscopy, indicating repulsive interactions between DWs of the same sign in the 20 nm thick wires. Micromagnetic simulations were used to identify the interactions in the six distinct cases of a pair of transverse DWs in adjacent wires, considering all the possible combinations of head-to-head and tail-to-tail DWs and the orientation of the core magnetization. The boundary between repulsive and attractive DW interactions is mapped out for wires as a function of thickness, width and interwire spacing.
Harbort, Johannes; Spiegel, Julia; Witthöft, Michael; Hecht, Heiko
2017-06-01
Patients with social anxiety disorder suffer from pronounced fears in social situations. As gaze perception is crucial in these situations, we examined which factors influence the range of gaze directions where mutual gaze is experienced (the cone of gaze). The social stimulus was modified by changing the number of people (heads) present and the emotional expression of their faces. Participants completed a psychophysical task, in which they had to adjust the eyes of a virtual head to gaze at the edge of the range where mutual eye-contact was experienced. The number of heads affected the width of the gaze cone: the more heads, the wider the gaze cone. The emotional expression of the virtual head had no consistent effect on the width of the gaze cone, it did however affect the emotional state of the participants. Angry expressions produced the highest arousal values. Highest valence emerged from happy faces, lowest valence from angry faces. These results suggest that the widening of the gaze cone in social anxiety disorder is not primarily mediated by their altered emotional reactivity. Implications for gaze assessment and gaze training in therapeutic contexts are discussed. Due to interindividual variability, enlarged gaze cones are not necessarily indicative of social anxiety disorder, they merely constitute a correlate at the group level. Copyright © 2016 Elsevier Ltd. All rights reserved.
Posnien, Nico; Koniszewski, Nikolaus Dieter Bernhard; Hein, Hendrikje Jeannette; Bucher, Gregor
2011-12-01
Several highly conserved genes play a role in anterior neural plate patterning of vertebrates and in head and brain patterning of insects. However, head involution in Drosophila has impeded a systematic identification of genes required for insect head formation. Therefore, we use the red flour beetle Tribolium castaneum in order to comprehensively test the function of orthologs of vertebrate neural plate patterning genes for a function in insect head development. RNAi analysis reveals that most of these genes are indeed required for insect head capsule patterning, and we also identified several genes that had not been implicated in this process before. Furthermore, we show that Tc-six3/optix acts upstream of Tc-wingless, Tc-orthodenticle1, and Tc-eyeless to control anterior median development. Finally, we demonstrate that Tc-six3/optix is the first gene known to be required for the embryonic formation of the central complex, a midline-spanning brain part connected to the neuroendocrine pars intercerebralis. These functions are very likely conserved among bilaterians since vertebrate six3 is required for neuroendocrine and median brain development with certain mutations leading to holoprosencephaly.
Hein, Hendrikje Jeannette; Bucher, Gregor
2011-01-01
Several highly conserved genes play a role in anterior neural plate patterning of vertebrates and in head and brain patterning of insects. However, head involution in Drosophila has impeded a systematic identification of genes required for insect head formation. Therefore, we use the red flour beetle Tribolium castaneum in order to comprehensively test the function of orthologs of vertebrate neural plate patterning genes for a function in insect head development. RNAi analysis reveals that most of these genes are indeed required for insect head capsule patterning, and we also identified several genes that had not been implicated in this process before. Furthermore, we show that Tc-six3/optix acts upstream of Tc-wingless, Tc-orthodenticle1, and Tc-eyeless to control anterior median development. Finally, we demonstrate that Tc-six3/optix is the first gene known to be required for the embryonic formation of the central complex, a midline-spanning brain part connected to the neuroendocrine pars intercerebralis. These functions are very likely conserved among bilaterians since vertebrate six3 is required for neuroendocrine and median brain development with certain mutations leading to holoprosencephaly. PMID:22216011
Kinoshita, Hideaki; Umezawa, Takashi; Omine, Yuya; Kasahara, Masaaki; Rodríguez-Vázquez, José Francisco; Murakami, Gen; Abe, Shinichi
2013-03-01
There is little or no information about the distribution of elastic fibers in the human fetal head. We examined this issue in 15 late-stage fetuses (crown-rump length, 220-320 mm) using aldehyde-fuchsin and elastica-Masson staining, and we used the arterial wall elastic laminae and external ear cartilages as positive staining controls. The posterior pharyngeal wall, as well as the ligaments connecting the laryngeal cartilages, contained abundant elastic fibers. In contrast with the sphenomandibular ligament and the temporomandibular joint disk, in which elastic fibers were partly present, the discomalleolar ligament and the fascial structures around the pterygoid muscles did not have any elastic fibers. In addition, the posterior marginal fascia of the prestyloid space did contain such fibers. Notably, in the middle ear, elastic fibers accumulated along the tendons of the tensor tympani and stapedius muscles and in the joint capsules of the ear ossicle articulations. Elastic fibers were not seen in any other muscle tendons or vertebral facet capsules in the head and neck. Despite being composed of smooth muscle, the orbitalis muscle did not contain any elastic fibers. The elastic fibers in the sphenomandibular ligament seemed to correspond to an intermediate step of development between Meckel's cartilage and the final ligament. Overall, there seemed to be a mini-version of elastic fiber distribution compared to that in adults and a different specific developmental pattern of connective tissues. The latter morphology might be a result of an adaptation to hypoxic conditions during development.
Ho, Ki Wai Kevin; Whitwell, George S; Young, Steve K
2012-07-01
We report how changes to our total hip arthroplasty (THA) surgical practise lead to a decrease in early hip dislocation rates. Group B consisted of 421 consecutive primary THA operations performed via a posterior approach. The operative technique included a meticulous repair of the posterior capsule, alignment of the acetabular cup with the transverse acetabular ligament (TAL) and a 36-mm-diameter femoral head. We compared the dislocation rates and cost implications of this technique to a historical control Group A consisting of 389 patients. The control group had their THA performed with no repair of the capsule, no identification of the TAL and all received a 28-mm-diameter head. Our primary outcome is the rate of early hip dislocation and we hypothesised that we can reduce the rate of early hip dislocation with this new regime. In Group B there were no early dislocations (within 6 months) and two (0.5 %) dislocations within 18 months; minimum follow-up time was 18 months with a range of (18-96 months). This compared to a 1.8 % early dislocation rate and a 2.6 % rate at 18 months in Group A; minimum follow-up time was 60 months with a range of (60-112 months). These results were statistically significant (p = 0.006). We suggest that when primary hip arthroplasty is performed through a posterior approach, a low early dislocation rate can be achieved using the described methods.
Kinoshita, Hideaki; Umezawa, Takashi; Omine, Yuya; Kasahara, Masaaki; Rodríguez-Vázquez, José Francisco; Murakami, Gen
2013-01-01
There is little or no information about the distribution of elastic fibers in the human fetal head. We examined this issue in 15 late-stage fetuses (crown-rump length, 220-320 mm) using aldehyde-fuchsin and elastica-Masson staining, and we used the arterial wall elastic laminae and external ear cartilages as positive staining controls. The posterior pharyngeal wall, as well as the ligaments connecting the laryngeal cartilages, contained abundant elastic fibers. In contrast with the sphenomandibular ligament and the temporomandibular joint disk, in which elastic fibers were partly present, the discomalleolar ligament and the fascial structures around the pterygoid muscles did not have any elastic fibers. In addition, the posterior marginal fascia of the prestyloid space did contain such fibers. Notably, in the middle ear, elastic fibers accumulated along the tendons of the tensor tympani and stapedius muscles and in the joint capsules of the ear ossicle articulations. Elastic fibers were not seen in any other muscle tendons or vertebral facet capsules in the head and neck. Despite being composed of smooth muscle, the orbitalis muscle did not contain any elastic fibers. The elastic fibers in the sphenomandibular ligament seemed to correspond to an intermediate step of development between Meckel's cartilage and the final ligament. Overall, there seemed to be a mini-version of elastic fiber distribution compared to that in adults and a different specific developmental pattern of connective tissues. The latter morphology might be a result of an adaptation to hypoxic conditions during development. PMID:23560235
Iwanowicz, D D; Iwanowicz, L R; Howerth, E W; Schill, W B; Blazer, V S; Johnson, R L
2013-02-01
Myxobolus stanlii sp. n. was described from largescale stonerollers ( Campostoma oligolepis ) from the Mobile River Basin in Alabama. The parasite was described using critical identifying morphological features, and the 18S small subunit ribosomal RNA (SSU rRNA) gene sequence. The spore body was ovoid, 10.03 ± 0.7 (7.5-11.0) μm long and 8.8 ± 1.5 (6.3-11.3) μm wide in frontal view. Spore thickness was 6.3 ± 2.7 (6.2-8.6) μm in sutural view. Polar capsules were pyriform, of equal size, and oriented in plane with the sutural ridge. Polar capsules were 2.45 ± 1.5 (range 2.1-4.3) μm in width and 4.6 ± 2.7 (range 4.5-6.9) μm in length. Based on the SSU rRNA gene sequence of Myxobolus stanlii sp. n. is most closely related to M. pseudodispar.
NASA Technical Reports Server (NTRS)
Fujimura, A.; Abe, M.; Yada, T.; Nakamura, T.; Noguchi, T.; Okazaki, R.; Ishibashi, Y.; Shirai, K.; Okada, T.; Yano, H.;
2011-01-01
Japanese spacecraft Hayabusa, which returned from near-Earth-asteroid Itokawa, successfully returned its reentry capsule to the Earth, the Woomera Prohibited Area in Australia in Jun 13th, 2010, as detailed in another paper [1]. The capsule introduced into the Planetary Material Sample Curation Facility in the Sagamihara campus of JAXA in the early morning of June 18th. Hereafter, we describe a series of processes for the returned capsule and the container to recover gas and materials in there. A transportation box of the recovered capsule was cleaned up on its outer surface beforehand and introduced into the class 10,000 clean room of the facility. Then, the capsule was extracted from the box and its plastic bag was opened and checked and photographed the outer surface of the capsule. The capsule was composed of the container, a backside ablator, a side ablator, an electronic box and a supporting frame. The container consists of an outer lid, an inner lid, a frame for latches, a container and a sample catcher, which is composed of room A and B and a rotational cylinder. After the first check, the capsule was packed in a plastic bag with N2 again, and transferred to the Chofu campus in JAXA, where the X-ray CT instrument is situated. The first X-ray CT analysis was performed on the whole returned capsule for confirming the conditions of latches and O-ring seal of the container. The analysis showed that the latches of the container should have worked normally, and that the double Orings of the container seemed to be sealed its sample catcher with no problem. After the first X-ray CT, the capsule was sent back to Sagamihara and introduced in the clean room to exclude the electronic box and the side ablator from the container by hand tools. Then the container with the backside ablator was set firmly to special jigs to fix the lid of container tightly to the container and set to a milling machine. The backside ablator was drilled by the machine to expose heads of bolts, which combined the ablator to the outer lid of the container, and after the drilling had been finished, all the bolts were unscrewed and the backside ablator was removed from the container. Then, the container was sent to the Chofu X-ray facility again to examine in detail by a micro X-ray CT instrument in order to reconfirm that the condition of the latches of the lid of container was normal and that its double O-ring seemed to have been sealed after the last X-ray CT analysis.
Portable wireless power transmission system for video capsule endoscopy.
Zhiwei, Jia; Guozheng, Yan; Bingquan, Zhu
2014-10-01
Wireless power transmission is considered a practical way of overcoming the power shortage of wireless capsule endoscopy (VCE). However, most patients cannot tolerate the long hours of lying in a fixed transmitting coil during diagnosis. To develop a portable wireless power transmission system for VCE, a compact transmitting coil and a portable inverter circuit driven by rechargeable batteries are proposed. The couple coils, optimized considering the stability and safety conditions, are 28 turns of transmitting coil and six strands of receiving coil. The driven circuit is designed according to the portable principle. Experiments show that the integrated system could continuously supply power to a dual-head VCE for more than 8 h at a frame rate of 30 frames per second with resolution of 320 × 240. The portable VCE exhibits potential for clinical applications, but requires further improvement and tests.
Inoue, Yasue; Komori, Chiharu; Kobayashi, Tadashi; Kondo, Natsuko; Ueno, Ryuhei; Takamura, Kenzi
2015-03-16
We identified a new species, Nanocladius (Plecopteracoluthus) shigaensis, from Shiga and Gifu Prefectures, Japan, whose larvae are phoretic on nymphs of Plecoptera. Although this new species is morphologically similar to Nanocladius (Plecopteracoluthus) asiaticus Hayashi (1998), which is phoretic on Megaloptera larvae, it differs from N. (P.) asiaticus: the color of the larval head capsule is light brown in N. (P.) shigaensis and dark brown in N. (P.) asiaticus and the larval capsule index of the former is significantly larger than that of the latter. Moreover, analyses based on DNA sequence of cytochrome c oxidase subunit I (COI) supported the hypothesis that N. (P.) shigaensis and N. (P.) asiaticus are two distinct species. This is the first record of a phoretic chironomid on a plecopteran nymph in the Palaearctic region.
Engesæter, Ingvild Øvstebø; Laborie, Lene Bjerke; Lehmann, Trude Gundersen; Sera, Francesco; Fevang, Jonas; Pedersen, Douglas; Morcuende, José; Lie, Stein Atle; Engesæter, Lars Birger; Rosendahl, Karen
2012-07-01
To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Tönnis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good.
Canyon formation constraints on the discharge of catastrophic outburst floods of Earth and Mars
NASA Astrophysics Data System (ADS)
Lapotre, Mathieu G. A.; Lamb, Michael P.; Williams, Rebecca M. E.
2016-07-01
Catastrophic outburst floods carved amphitheater-headed canyons on Earth and Mars, and the steep headwalls of these canyons suggest that some formed by upstream headwall propagation through waterfall erosion processes. Because topography evolves in concert with water flow during canyon erosion, we suggest that bedrock canyon morphology preserves hydraulic information about canyon-forming floods. In particular, we propose that for a canyon to form with a roughly uniform width by upstream headwall retreat, erosion must occur around the canyon head, but not along the sidewalls, such that canyon width is related to flood discharge. We develop a new theory for bedrock canyon formation by megafloods based on flow convergence of large outburst floods toward a horseshoe-shaped waterfall. The model is developed for waterfall erosion by rock toppling, a candidate erosion mechanism in well fractured rock, like columnar basalt. We apply the model to 14 terrestrial (Channeled Scablands, Washington; Snake River Plain, Idaho; and Ásbyrgi canyon, Iceland) and nine Martian (near Ares Vallis and Echus Chasma) bedrock canyons and show that predicted flood discharges are nearly 3 orders of magnitude less than previously estimated, and predicted flood durations are longer than previously estimated, from less than a day to a few months. Results also show a positive correlation between flood discharge per unit width and canyon width, which supports our hypothesis that canyon width is set in part by flood discharge. Despite lower discharges than previously estimated, the flood volumes remain large enough for individual outburst floods to have perturbed the global hydrology of Mars.
Impact of extra-articular pathologies on groin pain: An arthroscopic evaluation.
Kaya, Mitsunori
2018-01-01
For patients who have anterior hip pain evaluated by Patrick's test and tenderness at Scarpa's triangle, we perform periarticular debridement based on the hypothesis that extra-articular pathologies are responsible for the hip pain. The purpose of this study was to categorize the endoscopic extra-articular findings and to evaluate the clinical significance of periarticular pathologies in anterior hip pain. Arthroscopic findings of 77 patients who underwent periarthritic debridement were evaluated. As extra-articular pathologies, injuries of the direct head and reflective head of the rectus femoris muscle were evaluated. A thin layer of fat tissue normally exists on the anterior inferior iliac spine (AIIS), the attachment site of the direct head of the rectus femoris muscle. The macroscopic appearance of the fat pad on the AIIS was categorized as normal, blood vessel-rich adipose tissue or adipose tissue with fibrosis or scar formation and histologically confirmed. Adhesion of gluteal muscles to the joint capsule was also evaluated. Of the 77 patients, 75 had rupture of the direct head of the rectus femoris. In contrast, rupture of the reflective head was extremely rare. Seven patients had a normal fat pad on the AIIS, 11 had blood vessel-rich adipose tissue and 55 had adipose tissue with fibrosis. Fat tissue was completely replaced by fibrous scar tissue in another 4 patients. In 64 patients, adhesion between the anterior joint capsule and gluteus muscles was marked. Groin pain disappeared soon after the operation even when labral tears were not repaired and all patients returned to daily life and sports activities within 2 weeks after operation. Rectus femoris tendinosis, fibrosis of the AIIS fat pad, and adhesion of gluteal and rectus femoris muscles are common extra-articular pathologies in patients with anterior hip pain. Management of only these lesions induces rapid relief of anterior hip pain even in the absence of labral tear repair. My observations suggest that it is desirable to be aware of the presence of periarticular pathologies as a cause of groin pain.
NOL specular spin-valve heads using an ultrathin CoFe free layer
NASA Astrophysics Data System (ADS)
Fukuzawa, Hideaki; Koi, Katsuhiko; Tomita, Hiroshi; Fuke, Hiromi Niu; Kamiguchi, Yuzo; Iwasaki, Hitoshi; Sahashi, Masashi
2001-10-01
This paper reports the film and head performance of specular spin valves with nano-oxide layer (NOL-SPSV). A large MR ratio of 17% was obtained by using an ultrathin CoFe free layer with a high conductance Cu layer, which decreases the sense current field of a free layer and brings good soft magnetic characteristics. Prototype heads with a read track width of 0.47-0.61 μm were fabricated by using NOL-SPSV films with an MR ratio of 14-15%, Hua˜400 Oe, and Hc˜5 Oe. High output signal voltage of 8-11 mV/μm was realized in the NOL-SPSV heads.
33 CFR 110.195 - Mississippi River below Baton Rouge, LA, including South and Southwest Passes.
Code of Federal Regulations, 2011 CFR
2011-07-01
... river from mile 1.5 to mile 6.7 above Head of Passes, extending in width to 1600 feet from the left... along the left descending bank of the river from mile 8.0 to mile 9.6 above Head of Passes with the west... Venice Anchorage. An area 1.2 miles in length along the left descending bank of the river from mile 10.0...
33 CFR 110.195 - Mississippi River below Baton Rouge, LA, including South and Southwest Passes.
Code of Federal Regulations, 2010 CFR
2010-07-01
... river from mile 1.5 to mile 6.7 above Head of Passes, extending in width to 1600 feet from the left... along the left descending bank of the river from mile 8.0 to mile 9.6 above Head of Passes with the west... Venice Anchorage. An area 1.2 miles in length along the left descending bank of the river from mile 10.0...
Barros, L M; Martins, R T; Ferreira-Keppler, R L; Gutjahr, A L N
2017-08-04
Information on biomass is substantial for calculating growth rates and may be employed in the medicolegal and economic importance of Hermetia illucens (Linnaeus, 1758). Although biomass is essential to understanding many ecological processes, it is not easily measured. Biomass may be determined by directly weighing or indirectly through regression models of fresh/dry mass versus body dimensions. In this study, we evaluated the association between morphometry and fresh/dry mass of immature H. illucens using linear, exponential, and power regression models. We measured width and length of the cephalic capsule, overall body length, and width of the largest abdominal segment of 280 larvae. Overall body length and width of the largest abdominal segment were the best predictors for biomass. Exponential models best fitted body dimensions and biomass (both fresh and dry), followed by power and linear models. In all models, fresh and dry biomass were strongly correlated (>75%). Values estimated by the models did not differ from observed ones, and prediction power varied from 27 to 79%. Accordingly, the correspondence between biomass and body dimensions should facilitate and motivate the development of applied studies involving H. illucens in the Amazon region.
Pharyngeal diameter in various head and neck positions during exercise in sport horses
2014-01-01
Background In equine athletes, dynamic stenotic disorders of the upper airways are often the cause for abnormal respiratory noises and/or poor performance. There are hypotheses, that head and neck flexion may influence the morphology and function of the upper airway and thus could even induce or deteriorate disorders of the upper respiratory tract. Especially the pharynx, without osseous or cartilaginous support is prone to changes in pressure and airflow during exercise. The objective of this study was to develop a method for measuring the pharyngeal diameter in horses during exercise, in order to analyse whether a change of head-neck position may have an impact on the pharyngeal diameter. Results Under the assumption that the width of the epiglottis remains constant in healthy horses, the newly developed method for calculating the pharyngeal diameter in horses during exercise is unsusceptible against changes of the viewing-angle and distance between the endoscope and the structures, which are to be assessed. The quotient of the width of the epiglottis and the perpendicular from a fixed point on the dorsal pharynx to the epiglottis could be used to determine the pharyngeal diameter. The percentage change of this quotient (pharynx-epiglottis-ratio; PE-ratio) in the unrestrained head-neck position against the reference position was significantly larger than that of any other combination of the head-neck positions investigated. A relation between the percentage change in PE-ratio and the degree of head and neck flexion could not be confirmed. Conclusions It could be shown, that the pharyngeal diameter is reduced through the contact position implemented by the rider in comparison to the unrestrained head and neck position. An alteration of the pharyngeal diameter depending on the degree of head and neck flexion (represented by ground and withers angle) could not be confirmed. PMID:24886465
Extraarticular variants of the long head of the biceps brachii: a reminder of embryology.
Audenaert, Emmanuel A; Barbaix, Erik J; Van Hoonacker, Petrus; Berghs, Bart M
2008-01-01
Developmental anomalies of the long head of the biceps tendon are rare and have been described in the literature mainly dealing with anatomy and embryology. Because most basic embryologic research on this topic was conducted before 1966, a literature search was performed from archived anatomy textbooks and manuscript references. These data were compared with the scarce case descriptions of developmental anomalies of the long head of the biceps tendon. An additional case illustration from our own experience was provided. From the literature, it appears that during the embryologic phase of development, a staged migration of the long head of the biceps tendon occurs from a position between the fibrous capsule and synovial layer to an intraarticular position. Recent anatomic and arthroscopic case reports have shown that interruption of this migration can occur in any of these stages. Given the recent increase in arthroscopic shoulder surgery, anomalies of the long head of the biceps tendon will be encountered more frequently. Knowledge of their existence and origin can help in evaluating unexpected anatomic variations or the absence of the biceps tendon in preoperative medical imaging or during an arthroscopic procedure.
Tehranzadeh, Arash D; Fronek, Jan; Resnick, Donald
2007-01-01
In the high-performance athlete, acquired thickening of the posterior joint capsule is a proposed etiology for glenohumeral internal rotational deficit (GIRD). The purpose of this study was to present our MR arthrographic imaging observations of posterior capsular thickening in professional baseball players who present with reduced throwing velocity related to pain and clinical findings of internal rotational deficit of the glenohumeral joint. Our observations of MR imaging features in patients with clinical and arthroscopic manifestations of GIRD lesions include articular surface partial thickness tears of the supraspinatus and infraspinatus tendons, superoposterior subluxation of the humeral head and SLAP tears of the labrum. Although no empiric standard currently exists for the axial dimension thickness of the shoulder capsule, we have observed a thickened appearance of the posterior band of the inferior glenohumeral ligament in these patients.
2011-12-02
CAPE CANAVERAL, Fla. – At Port Canaveral in Florida, NASA's Liberty Star ship, with an Orion flight test capsule secured to its deck, passes the jetties as it heads toward the Atlantic Ocean. Liberty Star has been enlisted to support the Crew Module Recovery Attach Fitting Test (CRAFT) which began at-sea operations Nov. 29. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Tim Jacobs
2011-12-02
CAPE CANAVERAL, Fla. – At Port Canaveral in Florida, NASA's Liberty Star ship, with an Orion flight test capsule secured to its deck, heads out of port toward the Atlantic Ocean. Liberty Star has been enlisted to support the Crew Module Recovery Attach Fitting Test (CRAFT) which began at-sea operations Nov. 29. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Tim Jacobs
Pastor, Catalina; Lo Russo, Virginia; Villares, Gabriela
2015-10-06
Two new Parasavaljevia species are described, one from Puerto Madryn, and one from El Límite beach, San Jorge Gulf, Chubut Province, Argentina. The two species are characterised by a combination of characters. Parasavaljevia uncinoa n. sp. is characterised by having a long rectangular cirrus, positioned at the level of the inner labial setae, rectangular mandibles with prominent lateral hooks bearing denticles in three lines of nine each, and six cephalic setae of the same length, inserted at the anterior end of a small head capsule. Parasavaljevia limitense n. sp. is characterized by having a cirrus posterior positioned, between the labial and cephalic setae, rectangular-arched mandibles bearing denticles in five lines of ten each in a gradient of sizes; a small buccal cavity, small cephalic capsule and abundant cervical setae (4+10). An emendation of the genus diagnosis and a new key are given and discussed.
Rocha, Mauricio M.; Cancello, Eliana M.; Cuezzo, Carolina
2011-01-01
Abstract Acangaobitermes krishnai gen. et sp. n., is described here, based on soldiers and workers collected in Brazil. Some characteristics suggest a close kinship with Noirotitermes Cancello & Myles, and both genera share the following traits absent in all other Syntermitinae: the microsculpturing on the soldier head capsule surface with internal granulations; the piercing mandibles with a single very reduced marginal tooth and the worker very similar in both genera. The most conspicuous differences between Acangaobitermes and Noirotitermes are the shape of the soldier head, the frontal tube and pronotum. The shape of the soldier head in Noirotitermes is unusual, with a very broad and short frontal tube, four conspicuous protuberances like sharp corners at the rear, while in the new genus the posterior contour of the head is devoid of these protuberances. The frontal tube of Acangaobitermes is elongate and conical, while in Noirotitermes it is short and very broad. The pronotum of Acangaobitermes is saddle-shaped as is usual in other Syntermitinae, while it is aberrant in Noirotitermes. PMID:22287893
Gupta, Chandni; Kalthur, Sneha Guruprasad; Malsawmzuali, J C; D'souza, Antony Sylvan
2015-01-01
Knowledge of the size and shape of radial head is essential for construction of radial head prosthesis. Further, the measurements of bicipital tuberosity and its angular relationship to radial head are significant in surgical techniques, like in the reconstruction of biceps tendon. Even the morphometry of the distal radius is significant in numerous clinical orthopedic situations such as reduction of distal radius fractures and in the design of distal radius prosthesis. So, the aim of the study was to determine the morphometric parameters of proximal and distal radius in dry adult Indian radius. Fifty intact adult Indian radius (right = 23, left = 27) were chosen, and the various parameters of proximal and distal ends of radius were studied. Student's t-test was done to correlate all these parameters on the right and left sides. The mean length of radius, height of head at medial and lateral ends, head anteroposterior and transverse diameter, head thickness at ventral, dorsal, and lateral ends were 23.5, 0.90, 0.75, 1.91, 1.85, 0.42, 0.32, and 0.30 cm, respectively. The mean depth of articular facet, length of neck, proximal and distal neck diameter, width and length of bicipital tuberosity, and radial circumference at bicipital tuberosity were 0.19, 1.19, 1.36, 1.31, 1.23, 1.97, and 4.54 cm, respectively. The mean length of styloid process, oblique and transverse width of lower end, anteroposterior diameter of lower end, and angle of radial inclination were 0.98cm, 2. 81cm, 2.59cm, 1.86cm, and 25.05°, respectively. This study will be useful for orthopedic surgeons in making prosthesis for the proximal and distal ends of radius.
Preliminary Assessment of Primary Flight Display Symbology for Electro- Optic Head-Down Displays
1991-06-01
information :elated to pitch and power; the vertica! line provides information related to bank and heading. As a result of this geometrica ...steering bar are centered over the aircraft symbol. -n -1-- If the bars are centered, the aircraft is either correcting properly or is flying the desired...a•Isd bas,:ý muve to provide a new pitch command. Roll theading correction ) commands are seen as unbalanced line width, the low command bar side
Molecular Dynamics of a Water-Lipid Bilayer Interface
NASA Technical Reports Server (NTRS)
Wilson, Michael A.; Pohorille, Andrew
1994-01-01
We present results of molecular dynamics simulations of a glycerol 1-monooleate bilayer in water. The total length of analyzed trajectories is 5ns. The calculated width of the bilayer agrees well with the experimentally measured value. The interior of the membrane is in a highly disordered fluid state. Atomic density profile, orientational and conformational distribution functions, and order parameters indicate that disorder increases toward the center of the bilayer. Analysis of out-of-plane thermal fluctuations of the bilayer surfaces occurring at the time scale of the present calculations reveals that the distribution of modes agrees with predictions of the capillary wave model. Fluctuations of both bilayer surfaces are uncorrelated, yielding Gaussian distribution of instantaneous widths of the membrane. Fluctuations of the width produce transient thinning defects in the bilayer which occasionally span almost half of the membrane. The leading mechanism of these fluctuations is the orientational and conformational motion of head groups rather than vertical motion of the whole molecules. Water considerably penetrates the head group region of the bilayer but not its hydrocarbon core. The total net excess dipole moment of the interfacial water points toward the aqueous phase, but the water polarization profile is non-monotonic. Both water and head groups significantly contribute to the surface potential across the interface. The calculated sign of the surface potential is in agreement with that from experimental measurements, but the value is markedly overestimated. The structural and electrical properties of the water-bilayer system are discussed in relation to membrane functions, in particular transport of ions and nonelectrolytes across membranes.
Visual sensation during pecking in pigeons.
Ostheim, J
1997-10-01
During the final down-thrust of a pigeon's head, the eyes are closed gradually, a response that was thought to block visual input. This phase of pecking was therefore assumed to be under feed-forward control exclusively. Analysis of high resolution video-recordings showed that visual information collected during the down-thrust of the head could be used for 'on-line' modulations of pecks in progress. We thus concluded that the final down-thrust of the head is not exclusively controlled by feed-forward mechanisms but also by visual feedback components. We could further establish that as a rule the eyes are never closed completely but instead the eyelids form a slit which leaves a part of the pupil uncovered. The width of the slit between the pigeon' eyelids is highly sensitive to both, ambient luminance and the visual background against which seeds are offered. It was concluded that eyelid slits increase the focal depth of retinal images at extreme near-field viewing-conditions. Applying pharmacological methods we could confirm that pupil size and eyelid slit width are controlled through conjoint neuronal mechanisms. This shared neuronal network is particularly sensitive to drugs that affect dopamine receptors.
PowerWheel - A new look at waterwheels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weisman, R.N.; Broome, K.R.; Mayo, H.A.
1995-12-31
The PowerWheel is an advanced overshot water wheel, designed to generate electric power at drop structures on canals or on overflow spillways. Unlike the wheels of the 18th and 19th century which were designed to have maximum efficiency at a single flow rate, the current applications demand a wheel that can operate efficiently over a wide range of flows. The prototype PowerWheel will have a width to diameter ratio of 3 or more, in contrast to the wheels of the 19th century, which had large diameters and narrow widths. A model PowerWheel was built of plexiglass and delivered for testingmore » to the Imbt Hydraulics Laboratory at Lehigh University. The wheel has a diameter of 3.5 ft and is 16 in wide. The wheel contains 20 buckets and the bucket depth can be varied from a shallow depth of 4 in to a mid depth of 7 in to 10 in for the deep bucket. The blades have a rather simple geometry with a 4 in radius quarter circle at the outside of the wheel and then straight to the bottom of the bucket. The flume in which the wheel was tested has a width of 18 in. A hole was cut in the head box of the flume and a delivery chute was connected to the head box. The position of the chute can readily be moved up or down in relation to the wheel; for a fixed position of the chute on the head box, the slope of the chute can be changed because the chute was attached to the head box with a piano hinge. The laboratory flow system can deliver flow up to 6 cfs through a calibrated Venturi meter. The PowerWheel was subjected to flows ranging from 0.3 to 3.5 cfs.« less
Effect of the tubular-fan drum shapes on the performance of cleaning head module
NASA Astrophysics Data System (ADS)
Hong, C. K.; Y Cho, M.; Kim, Y. J.
2013-12-01
The geometrical effects of a tubular-fan drum on the performance improvement of the cleaning head module of a vacuum cleaner were investigated. In this study, the number of blades and the width of the blade were selected as the design parameters. Static pressure, eccentric vortex, turbulence kinetic energy (TKE) and suction efficiency were analysed and tabulated. Three-dimensional computational fluid dynamics method was used with an SST (Shear Stress Transfer) turbulence model to simulate the flow field at the suction of the cleaning head module using the commercial code ANSYS-CFX. Suction pressure distributions were graphically depicted for different values of the design parameters.
Hosseinpour, Mehdi; Yahaya, Ahmad Shukri; Sadullah, Ahmad Farhan
2014-01-01
Head-on crashes are among the most severe collision types and of great concern to road safety authorities. Therefore, it justifies more efforts to reduce both the frequency and severity of this collision type. To this end, it is necessary to first identify factors associating with the crash occurrence. This can be done by developing crash prediction models that relate crash outcomes to a set of contributing factors. This study intends to identify the factors affecting both the frequency and severity of head-on crashes that occurred on 448 segments of five federal roads in Malaysia. Data on road characteristics and crash history were collected on the study segments during a 4-year period between 2007 and 2010. The frequency of head-on crashes were fitted by developing and comparing seven count-data models including Poisson, standard negative binomial (NB), random-effect negative binomial, hurdle Poisson, hurdle negative binomial, zero-inflated Poisson, and zero-inflated negative binomial models. To model crash severity, a random-effect generalized ordered probit model (REGOPM) was used given a head-on crash had occurred. With respect to the crash frequency, the random-effect negative binomial (RENB) model was found to outperform the other models according to goodness of fit measures. Based on the results of the model, the variables horizontal curvature, terrain type, heavy-vehicle traffic, and access points were found to be positively related to the frequency of head-on crashes, while posted speed limit and shoulder width decreased the crash frequency. With regard to the crash severity, the results of REGOPM showed that horizontal curvature, paved shoulder width, terrain type, and side friction were associated with more severe crashes, whereas land use, access points, and presence of median reduced the probability of severe crashes. Based on the results of this study, some potential countermeasures were proposed to minimize the risk of head-on crashes. Copyright © 2013 Elsevier Ltd. All rights reserved.
Automated Tape Laying Machine for Composite Structures.
The invention comprises an automated tape laying machine, for laying tape on a composite structure. The tape laying machine has a tape laying head...neatly cut. The automated tape laying device utilizes narrow width tape to increase machine flexibility and reduce wastage.
Curvature-induced domain wall pinning
NASA Astrophysics Data System (ADS)
Yershov, Kostiantyn V.; Kravchuk, Volodymyr P.; Sheka, Denis D.; Gaididei, Yuri
2015-09-01
It is shown that a local bend of a nanowire is a source of pinning potential for a transversal head-to-head (tail-to-tail) domain wall. Eigenfrequency of the domain wall free oscillations at the pinning potential and the effective friction are determined as functions of the curvature and domain wall width. The pinning potential originates from the effective curvature-induced Dzyaloshinsky-like term in the exchange energy. The theoretical results are verified by means of micromagnetic simulations for the case of parabolic shape of the wire bend.
Sawkey, D L; Faddegon, B A
2009-03-01
Monte Carlo simulations of x-ray beams typically take parameters of the electron beam in the accelerating waveguide to be free parameters. In this paper, a methodology is proposed and implemented to determine the energy, spectral width, and beam divergence of the electron source. All treatment head components were removed from the beam path, leaving only the exit window. With the x-ray target and flattener out of the beam, uncertainties in physical characteristics and relative position of the target and flattening filter, and in spot size, did not contribute to uncertainty in the energy. Beam current was lowered to reduce recombination effects. The measured dose distributions were compared with Monte Carlo simulation of the electron beam through the treatment head to extract the electron source characteristics. For the nominal 6 and 18 MV x-ray beams, the energies were 6.51 +/- 0.15 and 13.9 +/- 0.2 MeV, respectively, with the uncertainties resulting from uncertainties in the detector position in the measurement and in the stopping power in the simulations. Gaussian spectral distributions were used, with full widths at half maximum ranging from 20 +/- 4% at 6 MV to 13 +/- 4% at 18 MV required to match the fall-off portion of the percent-depth ionization curve. Profiles at the depth of maximum dose from simulations that used the manufacturer-specified exit window geometry and no beam divergence were 2-3 cm narrower than measured profiles. Two simulation configurations yielding the measured profile width were the manufacturer-specified exit window thickness with electron source divergences of 3.3 degrees at 6 MV and 1.8 degrees at 18 MV and an exit window 40% thicker than the manufacturer's specification with no beam divergence. With the x-ray target in place (and no flattener), comparison of measured to simulated profiles sets upper limits on the electron source divergences of 0.2 degrees at 6 MV and 0.1 degrees at 18 MV. A method of determining source characteristics without mechanical modification of the treatment head, and therefore feasible in clinics, is presented. The energies and spectral widths determined using this method agree with those determined with only the exit window in the beam path.
Underbody Blast Models of TBI Caused by Hyper-Acceleration and Secondary Head Impact
2015-02-01
or behavioral indices of brain injury . 2.0 Technical Requirements: 2 Fig. 1. Diffusion tensor imaging of water diffusion in the internal capsule...demonstrates relative differences between blast (left) and sham (right) and also the similarities between the two animals in each group. vWF Bcl - 2 Fo ld...C ha ng e -8 -6 -4 - 2 0 2 4 6 8 10 12 ** ** Figure 6. Quantitative real-time polymerase chain reaction (qPCR) validation of vWF and Bcl - 2
Microsurgical anatomy of the central core of the brain.
Ribas, Eduardo Carvalhal; Yağmurlu, Kaan; de Oliveira, Evandro; Ribas, Guilherme Carvalhal; Rhoton, Albert
2017-12-22
OBJECTIVE The purpose of this study was to describe in detail the cortical and subcortical anatomy of the central core of the brain, defining its limits, with particular attention to the topography and relationships of the thalamus, basal ganglia, and related white matter pathways and vessels. METHODS The authors studied 19 cerebral hemispheres. The vascular systems of all of the specimens were injected with colored silicone, and the specimens were then frozen for at least 1 month to facilitate identification of individual fiber tracts. The dissections were performed in a stepwise manner, locating each gray matter nucleus and white matter pathway at different depths inside the central core. The course of fiber pathways was also noted in relation to the insular limiting sulci. RESULTS The insular surface is the most superficial aspect of the central core and is divided by a central sulcus into an anterior portion, usually containing 3 short gyri, and a posterior portion, with 2 long gyri. It is bounded by the anterior limiting sulcus, the superior limiting sulcus, and the inferior limiting sulcus. The extreme capsule is directly underneath the insular surface and is composed of short association fibers that extend toward all the opercula. The claustrum lies deep to the extreme capsule, and the external capsule is found medial to it. Three fiber pathways contribute to form both the extreme and external capsules, and they lie in a sequential anteroposterior disposition: the uncinate fascicle, the inferior fronto-occipital fascicle, and claustrocortical fibers. The putamen and the globus pallidus are between the external capsule, laterally, and the internal capsule, medially. The internal capsule is present medial to almost all insular limiting sulci and most of the insular surface, but not to their most anteroinferior portions. This anteroinferior portion of the central core has a more complex anatomy and is distinguished in this paper as the "anterior perforated substance region." The caudate nucleus and thalamus lie medial to the internal capsule, as the most medial structures of the central core. While the anterior half of the central core is related to the head of the caudate nucleus, the posterior half is related to the thalamus, and hence to each associated portion of the internal capsule between these structures and the insular surface. The central core stands on top of the brainstem. The brainstem and central core are connected by several white matter pathways and are not separated from each other by any natural division. The authors propose a subdivision of the central core into quadrants and describe each in detail. The functional importance of each structure is highlighted, and surgical approaches are suggested for each quadrant of the central core. CONCLUSIONS As a general rule, the internal capsule and its vascularization should be seen as a parasagittal barrier with great functional importance. This is of particular importance in choosing surgical approaches within this region.
Characterization of Akiyama probe applied to dual-probes atomic force microscope
NASA Astrophysics Data System (ADS)
Wang, Hequn; Gao, Sitian; Li, Wei; Shi, Yushu; Li, Qi; Li, Shi; Zhu, Zhendong
2016-10-01
The measurement of nano-scale line-width has always been important and difficult in the field of nanometer measurements, while the rapid development of integrated circuit greatly raises the demand again. As one kind of scanning probe microscope (SPM), atomic force microscope (AFM) can realize quasi three-dimensional measurement, which is widely used in nanometer scale line-width measurement. Our team researched a dual-probes atomic force microscope, which can eliminate the prevalent effect of probe width on measurement results. In dual-probes AFM system, a novel head are newly designed. A kind of self-sensing and self-exciting probes which is Nanosensors cooperation's patented probe—Akiyama probe, is used in this novel head. The Akiyama probe applied to dual-probe atomic force microscope is one of the most important issues. The characterization of Akiyama probe would affect performance and accuracy of the whole system. The fundamental features of the Akiyama probe are electrically and optically characterized in "approach-withdraw" experiments. Further investigations include the frequency response of an Akiyama probe to small mechanical vibrations externally applied to the tip and the effective loading force yielding between the tip and the sample during the periodic contact. We hope that the characterization of the Akiyama probe described in this paper will guide application for dual-probe atomic force microscope.
Kukita, Sayuri; Gouda, Mika; Ikeda, Sakiko; Ishibashi, Sakiko; Furuya, Tatsunori; Nakamura, Keiji
2015-06-01
Day length is one of the most important factors that organisms use to predict seasonal changes in their environment. Several amphibians regulate their growth and development in response to photoperiod. However, many studies have not focused on the ecological effects of the photoperiodic response on growth and development because they use tropical animals, animals from a commercial source or from unknown localities, or extreme light regimens for experiments. In the present study, we examined the effects of photoperiod on growth and development in the clouded salamander (Hynobius nebulosus) by raising larvae under different photoperiods and at different temperatures in the laboratory. The average larval period under a long-day photoperiod of L16:D8 was longer than that under L12:D12 at 15°C or 20°C, although the difference between the photoperiods was only significant for 15°C. Juveniles weighed more at metamorphosis under L16:D8 than those under L12:D12, irrespective of temperature, suggesting that a longer developmental period results in a heavier body weight. The head width of juveniles did not differ for different photoperiods at either temperature. However, the growth rate of the head width under L12:D12 was faster than that under L16:D8 at 15°C. Long day length appears to produce larger H. nebulosus juveniles in a relatively stable aquatic environment with a low population density. Thus, development may be accelerated when the day length becomes shorter as winter approaches, and larvae may have increased the growth rate of their head widths to compensate for the shorter growing period under shorter day lengths.
Effects of temperature on Anoplophora glabripennis (Coleoptera: Cerambycidae) larvae and pupae.
Keena, M A; Moore, P M
2010-08-01
Developmental thresholds, degree-days for development, larval weights, and head capsule widths for each larval instar and the pupal stage of Anoplophora glabripennis (Motschulsky) (Coleoptera: Cerambycidae) were studied at eight constant temperatures (5, 10, 15, 20, 25, 30, 35, and 40°C) for two source populations (Ravenswood, Chicago, IL [IL], and Bayside, Queens, NY [NY]). The estimated lower threshold temperature for development of instars 1-5 and the pupal stage was near 10°C and was near 12°C for the higher instars. Developmental rate was less temperature sensitive for instars 5-9 compared with instars 1-4. Development for all but the first instar was inhibited at constant temperatures >30°C, and all instars failed to develop at 40°C. Although the two source populations had similar responses to temperature, IL larvae were heavier than those from NY. Temperature and its influence on larval weight had profound impacts on whether a larva proceeded to pupation. Based on the temperature effects detailed here, larval development and pupation should be possible in most of the continental United States where suitable hosts are available. These data can be used to develop a degree-day model to estimate beetle phenology; however, at least 2°C should be added to air temperatures to adjust for the mediation of temperature by the wood. These data provide a basis for predicting the potential geographical range of this species and for developing phenological models to predict the timing of immature stages, both of which are important for management programs.
Shrestha, Anita; Srinivasan, Rajagopalbabu; Sundaraj, Sivamani; Culbreath, Albert K; Riley, David G
2013-04-01
Spotted wilt disease caused by Tomato spotted wilt virus (TSWV) (family Bunyaviridae; genus Tospovirus) is a major constraint to peanut (Arachis hypogaea L.) production in the southeastern United States. Reducing yield losses to TSWV has heavily relied on planting genotypes that reduce the incidence of spotted wilt disease. However, mechanisms conferring resistance to TSWV have not been identified in these genotypes. Furthermore, no information is available on how these genotypes influence thrips fitness. In this study, we investigated the effects of newly released peanut genotypes (Georganic, GA-06G, Tifguard, and NC94022) with field resistance to TSWV and a susceptible genotype (Georgia Green) on tobacco thrips, Frankliniella fusca (Hinds), fitness, and TSWV incidence. Thrips-mediated transmission resulted in TSWV infection in both TSWV-resistant and susceptible genotypes and they exhibited typical TSWV symptoms. However, some resistant genotypes had reduced viral loads (fewer TSWV N-gene copies) than the susceptible genotype. F. fusca larvae acquired TSWV from resistant and susceptible genotypes indicating that resistant genotypes also can serve as inoculum sources. Unlike resistant genotypes in other crops that produce local lesions (hypersensitive reaction) upon TSWV infection, widespread symptom development was noticed in peanut genotypes. Results indicated that the observed field resistance in peanut genotypes could be because of tolerance. Further, fitness studies revealed some, but not substantial, differences in thrips adult emergence rates and developmental time between resistant and susceptible genotypes. Thrips head capsule length and width were not different when reared on different genotypes.
Ahn, Kyu-Sung; Oh, Dae-Sung; Ahn, Ah-Jin; Suh, Guk-Hyun
2013-01-01
This study describes the first record of Bourgelatia diducta (Nematoda: Chabertiidae) from wild boars in the Republic of Korea (=South Korea). Gastrointestinal tracts of 87 Korean wild boars (Sus scrofa coreanus) hunted in mountains in the south-western part of South Korea between 2009 and 2012 were examined for their visceral helminths. B. diducta, as identified by morphological characteristics of the head and tail, were recovered from the large intestine of 47 (54%) wild boars. The average length of adult female worms was 11.3±0.87 mm and the thickest part of the body measured 0.54±0.04 mm in maximum width, while those of males were 9.8±0.72 and 0.45±0.03 mm, respectively. The characteristic J-shaped type II ovejector was observed in females, and the type II dorsal ray with 2 rami on each side of the median fissure was uniquely seen in males. The buccal capsule was small, relatively thin-walled, cylindrical, very short, and ring-shaped. The externodorsal ray arose from a common stem with the dorsal ray. The cervical groove was absent. The anterior extremity was equipped with 20-22 external corona radiata, 4 cephalic papillae and 2 lateral amphids around the mouth. The eggs were 66.0×38.9 µm in average size. By the present study, B. diducta (Nematoda: Chabertiidae) is recorded for the first time in South Korea. Additionally, morphological characteristics and identification keys provided in the present study will be helpful in the faunistic or taxonomic studies for strongylid nematodes related. PMID:24039287
Cuban Calisto (Lepidoptera, Nymphalidae, Satyrinae), a review based on morphological and DNA data
Aguila, Rayner Núñez; Plasencia, Edelquis Oliva; Maravi, Pavel F. Matos; Wahlberg, Niklas
2012-01-01
Abstract The Cuban species of Calisto are reviewed based on the morphology of adult and immature stages, as well as DNA sequences of six genes (COI, EF1α, wingless, GAPDH, RpS5, CAD). A new species, Calisto occulta sp. n., is described from the northeastern Cuban mountains. Calisto smintheus Bates, 1935 and Calisto bruneri, Michener 1949 are revised and revalidated. A new status, the species level, is proposed for Calisto brochei, Torre 1973, Calisto muripetens, Bates 1939 and Calisto bradleyi, Munroe 1950. The immature stages of Calisto smintheus, Calisto brochei,and Calisto occulta are described for the first time, and those of Calisto herophile, Hübner 1823 are redescribed. Useful morphological characters for adults are the shape and conspicuousness of androconial patch, the number and relative size of white dots on underside of hindwing, the shape of aedeagus, the shape of digitiform projection of genitalia valve, the shape and relative size of tegumen and uncus, the relative size of female genitalia, the height of sterigmal ring dorsal crown of the latter, and the relative size of corpus bursae and ductus bursae. For the immature stages, the most important characters are the color pattern of head capsule, the number and width of longitudinal lines of body, in the larvae; and the color pattern and the absence or presence of dorsal ridges on the abdomen of pupae. The phylogenetic relationships between the Cuban Calisto species are quite robust and well-supported; however, conflict between mitochondrial and nuclear datasets was detected in Calisto brochei, Calisto muripetens and to a lesser degree in Calisto bradleyi. PMID:22328857
Ahn, Kyu-Sung; Oh, Dae-Sung; Ahn, Ah-Jin; Suh, Guk-Hyun; Shin, Sung-Shik
2013-08-01
This study describes the first record of Bourgelatia diducta (Nematoda: Chabertiidae) from wild boars in the Republic of Korea (=South Korea). Gastrointestinal tracts of 87 Korean wild boars (Sus scrofa coreanus) hunted in mountains in the south-western part of South Korea between 2009 and 2012 were examined for their visceral helminths. B. diducta, as identified by morphological characteristics of the head and tail, were recovered from the large intestine of 47 (54%) wild boars. The average length of adult female worms was 11.3±0.87 mm and the thickest part of the body measured 0.54±0.04 mm in maximum width, while those of males were 9.8±0.72 and 0.45±0.03 mm, respectively. The characteristic J-shaped type II ovejector was observed in females, and the type II dorsal ray with 2 rami on each side of the median fissure was uniquely seen in males. The buccal capsule was small, relatively thin-walled, cylindrical, very short, and ring-shaped. The externodorsal ray arose from a common stem with the dorsal ray. The cervical groove was absent. The anterior extremity was equipped with 20-22 external corona radiata, 4 cephalic papillae and 2 lateral amphids around the mouth. The eggs were 66.0×38.9 µm in average size. By the present study, B. diducta (Nematoda: Chabertiidae) is recorded for the first time in South Korea. Additionally, morphological characteristics and identification keys provided in the present study will be helpful in the faunistic or taxonomic studies for strongylid nematodes related.
NASA Astrophysics Data System (ADS)
Ohkubo, Toshifumi; Hirota, Terunao; Oumi, Manabu; Hirata, Masakazu; Nakajima, Kunio
2004-10-01
Advances in a digital network society require both higher densities and higher transfer rates in all sorts of storage devices. In optical recording, the trend toward higher recording density and larger storage capacity requires novel surface recording technologies that would drastically improve recording density. To satisfy these severe requirements, we have already proposed a compact integrated optical head slider assembly for proximity optical recording based on the "near field principle". Using the optical head slider, we have successfully demonstrated readout signals from 200 to 150-nm-long bit patterns at frequency bands up to approximately 10 MHz. However, from the practical point of view, it is quite necessary to evaluate readout signals from patterns of smaller (sub-micron to sub-sub-micron) track width in order to prove high-density recording potential. In this paper, we have investigated tracking accuracy characteristics utilizing sub-micron sized alternate patterns of 1-mm length formed in a straight line in the circumferential direction of the medium. Arranging precisely the head's relative position to these recorded patterns, we have successfully obtained readout signals just crossing the sub-micron line-and-space pattern's boundaries. Assuming that an aperture runs along an accurate trajectory of the arc of a circle, readout signal amplitude variations when crossing the pattern edge at a right angle have precisely predicted. Also, the influences of track width on maximum readout signal intensity and tracking sensitivity are discussed in detail.
Nonlinear-regression flow model of the Gulf Coast aquifer systems in the south-central United States
Kuiper, L.K.
1994-01-01
A multiple-regression methodology was used to help answer questions concerning model reliability, and to calibrate a time-dependent variable-density ground-water flow model of the gulf coast aquifer systems in the south-central United States. More than 40 regression models with 2 to 31 regressions parameters are used and detailed results are presented for 12 of the models. More than 3,000 values for grid-element volume-averaged head and hydraulic conductivity are used for the regression model observations. Calculated prediction interval half widths, though perhaps inaccurate due to a lack of normality of the residuals, are the smallest for models with only four regression parameters. In addition, the root-mean weighted residual decreases very little with an increase in the number of regression parameters. The various models showed considerable overlap between the prediction inter- vals for shallow head and hydraulic conductivity. Approximate 95-percent prediction interval half widths for volume-averaged freshwater head exceed 108 feet; for volume-averaged base 10 logarithm hydraulic conductivity, they exceed 0.89. All of the models are unreliable for the prediction of head and ground-water flow in the deeper parts of the aquifer systems, including the amount of flow coming from the underlying geopressured zone. Truncating the domain of solution of one model to exclude that part of the system having a ground-water density greater than 1.005 grams per cubic centimeter or to exclude that part of the systems below a depth of 3,000 feet, and setting the density to that of freshwater does not appreciably change the results for head and ground-water flow, except for locations close to the truncation surface.
A new static sampler for airborne total dust in workplaces.
Mark, D; Vincent, J H; Gibson, H; Lynch, G
1985-03-01
This paper describes the development and laboratory testing of a new static dust sampler for airborne total dust in workplaces. Particular attention is paid to designing the sampling head and entry consistent with the concept of inspirability which in turn defines a biologically-relevant aspiration efficiency. The sampling head has a small cylindrical body and a transverse entry slot with thin protruding lips forming an integral part of a weighable capsule containing a 37 mm filter which collects all of the sampled dust (without introducing errors due to external particle blow-off or internal wall losses). A battery-powered sampling pump provides both air suction at 3 L/min and rigid mounting for the sampling head. The sampling head is rotated continuously through 360 degrees at approximately 1.5 rpm by a simple electric drive, connected to the stationary pump through a rotating seal. Wind tunnel testing of the instrument showed it to display an entry efficiency very close to the inspirability curve of Vincent and Armbruster (now recommended by the ACGIH Technical Committee on Air Sampling Procedures for defining inspirable particulate matter (IPM] for particles of aerodynamic diameter up to 90 micron and for windspeeds in the range of one to three m/sec.
Estimating a child's age from an image using whole body proportions.
Lucas, Teghan; Henneberg, Maciej
2017-09-01
The use and distribution of child pornography is an increasing problem. Forensic anthropologists are often asked to estimate a child's age from a photograph. Previous studies have attempted to estimate the age of children from photographs using ratios of the face. Here, we propose to include body measurement ratios into age estimates. A total of 1603 boys and 1833 girls aged 5-16 years were measured over a 10-year period. They are 'Cape Coloured' children from South Africa. Their age was regressed on ratios derived from anthropometric measurements of the head as well as the body. Multiple regression equations including four ratios for each sex (head height to shoulder and hip width, knee width, leg length and trunk length) have a standard error of 1.6-1.7 years. The error is of the same order as variation of differences between biological and chronological ages of the children. Thus, the error cannot be minimised any further as it is a direct reflection of a naturally occurring phenomenon.
Size effect on cold-welding of gold nanowires investigated using molecular dynamics simulations
NASA Astrophysics Data System (ADS)
Wu, Cheng-Da; Fang, Te-Hua; Wu, Chung-Chin
2016-03-01
The size effect on the cold-welding mechanism and mechanical properties of Au nanowires (NWs) in head-to-head contact are studied using molecular dynamics simulations based on the second-moment approximation of the many-body tight-binding potential. The results are discussed in terms of atomic trajectories, slip vectors, stress, radial distribution function, and weld strength ratio. Simulation results show that during the cold-welding process, a few disordered atoms/defects in the jointing area rearrange themselves and transform into a face-centered cubic crystalline structure. With an increase in contact between the two NWs, dislocations gradually form on the (111) slip plane and then on a twin plane, leading to an increase in the lateral deformation of 4-nm-wide NWs. The effect of structural instability increases with decreasing NW width, making the alignment of the two NWs more difficult. The elongation ability of the welded NWs increases with increasing NW width. Smaller NWs have better weld strength.
Rosser, Thomas G; Baumgartner, Wes A; Barger, Michael A; Griffin, Matt J
2017-05-01
A parasitological survey of freshwater fishes in the Big Thicket National Preserve in southeast Texas revealed myxozoan infections in two species of sunfish, Lepomis marginatus Holbrook and Lepomis miniatus Jordan (Perciformes: Centrarchidae). Pseudocysts were elongate-oval, 988 × 485 µm (ex L. marginatus) and 800 × 606 µm (ex L. miniatus) and demonstrated a predilection to the edge of the primary gill lamellae. Myxospores consistent with the genus Myxobolus were oblong, 16.8-21.3 (19.0 ± 0.9) µm long, 7.0-8.8 (7.9 ± 0.5) µm wide and 5.3-6.1 (5.8 ± 0.3) µm thick (ex L. marginatus) and 17.2-20.3 (18.8 ± 0.7) µm long, 7.5-9.9 (8.7 ± 0.6) µm wide, and 6.8-7.2 (7.0 ± 0.2) µm thick (ex L. miniatus); with 2 pyriform polar capsules 8.3-9.8 (9.0 ± 0.5) µm long, 2.2-2.7 (2.5 ± 0.2) µm wide (ex L. marginatus) and 9.2-10.5 (10.0 ± 0.4) µm long, 2.2-3.0 (2.8 ± 0.2) µm wide (ex L. miniatus). Statistically, the measurements of spore body width, polar capsule length, and polar capsule width were significantly different between myxospores from L. marginatus and L. miniatus. However, intraspecific genetic variability between isolates at the 18S rRNA gene was negligible, with < 0.8% variability across > 2,000 bp of sequence. The isolates shared no significant sequence similarity with any myxozoan deposited in the GenBank nucleotide database. Phylogenetic analysis inferred from the 18S rRNA gene from both L. marginatus and L. miniatus placed the isolates within a clade of myxozoan parasites of perciform fishes. Based on shared tissue and host family tropism, overlapping morphological characters and high degrees of sequence conservation at the 18S rRNA gene, we propose these isolates as morphologically distinct, genetically conspecific representatives of M. lepomis n. sp. from the gills of L. marginatus and L. miniatus in the Big Thicket National Preserve in Texas, USA.
Brewer, S.K.; Atchison, G.J.
1999-01-01
We examined head capsule cholinesterase (ChE) and foraging behavior in nymphs of the dragonfly, Anax junius, exposed for 24 h to 0.2, 0.6 and 1.0 ??g l-1 of the organophosphorus (OP) insecticide, chlorpyrifos [O,O-diethyl O-(3,5,6-trichloro-2-pyridyl) phosphorothioate]. The invertebrate community is an important component of the structure and function of wetland ecosystems, yet the potential effects of insecticides on wetland ecosystems are largely unknown. Our objectives were to determine if exposure to environmentally realistic concentrations of chlorpyrifos affected foraging behavior and ChE activity in head capsules of dragonfly nymphs. Nymphs were exposed to different concentrations of chlorpyrifos and different prey densities in a factorial design. ChE activities and foraging behaviors of treated nymphs were not statistically different (p ??? 0.05) from control groups. Prey density effects exerted a greater effect on dragonfly foraging than toxicant exposures. Nymphs offered higher prey densities exhibited more foraging behaviors but also missed their prey more often. High variability in ChE activities within the control group and across treated groups precluded determination of relationships between ChE and foraging behaviors. It appears that A. junius is relatively tolerant of chlorpyrifos, although the concentrations we tested have been shown in other work to adversely affect the prey base; therefore the introduction of this insecticide may have indirect adverse affects on top invertebrate predators such as Odonata.
Posnien, Nico; Hopfen, Corinna; Hilbrant, Maarten; Ramos-Womack, Margarita; Murat, Sophie; Schönauer, Anna; Herbert, Samantha L; Nunes, Maria D S; Arif, Saad; Breuker, Casper J; Schlötterer, Christian; Mitteroecker, Philipp; McGregor, Alistair P
2012-01-01
A striking diversity of compound eye size and shape has evolved among insects. The number of ommatidia and their size are major determinants of the visual sensitivity and acuity of the compound eye. Each ommatidium is composed of eight photoreceptor cells that facilitate the discrimination of different colours via the expression of various light sensitive Rhodopsin proteins. It follows that variation in eye size, shape, and opsin composition is likely to directly influence vision. We analyzed variation in these three traits in D. melanogaster, D. simulans and D. mauritiana. We show that D. mauritiana generally has larger eyes than its sibling species, which is due to a combination of larger ommatidia and more ommatidia. In addition, intra- and inter-specific differences in eye size among D. simulans and D. melanogaster strains are mainly caused by variation in ommatidia number. By applying a geometric morphometrics approach to assess whether the formation of larger eyes influences other parts of the head capsule, we found that an increase in eye size is associated with a reduction in the adjacent face cuticle. Our shape analysis also demonstrates that D. mauritiana eyes are specifically enlarged in the dorsal region. Intriguingly, this dorsal enlargement is associated with enhanced expression of rhodopsin 3 in D. mauritiana. In summary, our data suggests that the morphology and functional properties of the compound eyes vary considerably within and among these closely related Drosophila species and may be part of coordinated morphological changes affecting the head capsule.
Trivedi, Suraj; Pomerantz, Michael L; Gross, Daniel; Golijanan, Petar; Provencher, Matthew T
2014-08-01
An assortment of variables has been used in predicting anterior shoulder instability resulting from pathologic engagement of Hill-Sachs lesions on the glenoid. The glenoid track is a unique biomechanical model that relates both Hill-Sachs and bony Bankart lesions to predict shoulder engagement. We examined the glenoid track concept to determine if it provides a model that unifies glenoid rim and humeral head bone loss in predicting engagement. In this review we addressed two questions: (1) How are humeral head and glenoid rim bony defects and their interactions quantified? (2) Why is the concept of the glenoid track important? We performed a systematic review of the literature using PubMed (MEDLINE) and OVID for biomechanical studies and peer-reviewed articles published until March 2013. Twenty-four studies fit the inclusion criteria. These were subdivided into four anatomic studies, four studies quantifying glenohumeral bone loss, nine studies biomechanically defining shoulder engagement, six studies analyzing current treatment models, and one clinical study to be included in the final review. Data demonstrate pathologic engagement is dependent on the medial margin of the Hill-Sachs lesion traveling outside the glenoid track. The width of the glenoid track decreases accordingly if there is a glenoid defect, making engagement more likely. Most treatment models focus on widening the glenoid track before addressing Hill-Sachs lesions. The glenoid track uses both glenoid and humeral head bone loss to predict subsequent risk of humeral head engagement and possible dislocation. The glenoid track shows us that restoring the track to its natural width should be among the surgeon's first priority in restoring shoulder stability. Humeral head lesions, also known as Hill-Sachs lesions, are surgically addressed when they cause clinical symptoms. Symptoms arise when the medial margin of the defect engages the glenoid track.
Evaluation of confidence intervals for a steady-state leaky aquifer model
Christensen, S.; Cooley, R.L.
1999-01-01
The fact that dependent variables of groundwater models are generally nonlinear functions of model parameters is shown to be a potentially significant factor in calculating accurate confidence intervals for both model parameters and functions of the parameters, such as the values of dependent variables calculated by the model. The Lagrangian method of Vecchia and Cooley [Vecchia, A.V. and Cooley, R.L., Water Resources Research, 1987, 23(7), 1237-1250] was used to calculate nonlinear Scheffe-type confidence intervals for the parameters and the simulated heads of a steady-state groundwater flow model covering 450 km2 of a leaky aquifer. The nonlinear confidence intervals are compared to corresponding linear intervals. As suggested by the significant nonlinearity of the regression model, linear confidence intervals are often not accurate. The commonly made assumption that widths of linear confidence intervals always underestimate the actual (nonlinear) widths was not correct. Results show that nonlinear effects can cause the nonlinear intervals to be asymmetric and either larger or smaller than the linear approximations. Prior information on transmissivities helps reduce the size of the confidence intervals, with the most notable effects occurring for the parameters on which there is prior information and for head values in parameter zones for which there is prior information on the parameters.The fact that dependent variables of groundwater models are generally nonlinear functions of model parameters is shown to be a potentially significant factor in calculating accurate confidence intervals for both model parameters and functions of the parameters, such as the values of dependent variables calculated by the model. The Lagrangian method of Vecchia and Cooley was used to calculate nonlinear Scheffe-type confidence intervals for the parameters and the simulated heads of a steady-state groundwater flow model covering 450 km2 of a leaky aquifer. The nonlinear confidence intervals are compared to corresponding linear intervals. As suggested by the significant nonlinearity of the regression model, linear confidence intervals are often not accurate. The commonly made assumption that widths of linear confidence intervals always underestimate the actual (nonlinear) widths was not correct. Results show that nonlinear effects can cause the nonlinear intervals to be asymmetric and either larger or smaller than the linear approximations. Prior information on transmissivities helps reduce the size of the confidence intervals, with the most notable effects occurring for the parameters on which there is prior information and for head values in parameter zones for which there is prior information on the parameters.
2011-01-01
ABSTRACT Purpose: The purpose of this case study is to describe the management of a female patient with chronic left low back pain and sacroiliac joint pain (LBP/SIJP) using unique unilateral exercises developed by the Postural Restoration Institute (PRI) to address pelvic asymmetry and left hip capsule restriction, which is consistent with a Right Handed and Left Anterior Interior Chain pattern of postural asymmetry. Client Description: The client was 65-year-old woman with a 10-month history of constant left LBP/SIJP and leg pain. Intervention: The patient was seen six times to correct pelvic position/posture and left hip posterior capsule restriction via (1) muscle activation (left hamstrings, adductor magnus, and anterior gluteus medius) and (2) left hip adduction to lengthen the left posterior capsule/ischiofemoral ligament. Stabilization exercises included bilateral hamstrings, gluteus maximus, adductors, and abdominals to maintain pelvic position/posture. Measures and Outcome: Left Ober's test (initially positive) was negative at discharge. Pain as measured on the Numeric Pain Rating Scale (initially 1/10 at best and 8/10 at worst) was 0/10–0/10 at discharge. Oswestry Disability Index score (initially 20%) was 0% at discharge. The patient no longer had numbness in her left leg, and sexual intercourse had become pain free. Implications: Interventions to restore and maintain the optimal position of pelvis and hip (femoral head in the acetabulum) may be beneficial for treating patients with chronic LBP/SIJP. The patient's pain was eliminated 13 days after she first performed three exercises to reposition the pelvis and restore left posterior hip capsule extensibility and internal rotation. PMID:22379254
Hydraulic Reconstructions of Outburst Floods on Earth and Mars
NASA Astrophysics Data System (ADS)
Lapotre, M. G. A.; Lamb, M. P.
2014-12-01
Large outburst floods on Earth and Mars have carved bedrock canyons in basalt that often have steep sidewalls and amphitheater heads, suggesting erosion by waterfall retreat and block toppling. Two paleohydraulic methods are typically used to reconstruct flood discharges. The first is based on the discharge required to move sediment, which requires rare grain-size data and is necessarily a lower bound. The second assumes bedrock canyons are entirely inundated, which likely greatly overestimates the discharge of canyon carving floods. Here we explore a third hypothesis that canyon width is an indicator of flood discharge. For example, we expect that for large floods relative to the canyon width, the canyon will tend to widen as water spills over and erodes the canyon sidewalls. In contrast, small floods, relative to the canyon size will tend to focus flow into the canyon head, resulting in a narrowing canyon. To test this hypothesis, we need data on how outburst floods focus water into canyons across a wide range of canyon and flood sizes. To fill this data gap, we performed a series of numerical simulations solving the 2D depth-averaged shallow water equations for turbulent flow. We analyzed the effect of five non-dimensional parameters on the shear stress and discharge distributions around head and sidewalls of canyons of different sizes. The Froude number of the flood has the greatest effect on the distribution of shear stresses and discharges around the canyon rim; higher Froude numbers lead to less convergence of the flow towards the canyon, and thus to lower shear stresses (and discharges) on the sides of the canyon. Simulation results show that canyons of constant width were likely carved by floods within a relatively narrow range of discharges. The range of discharges is sensitive to the Froude number and size of blocks that are toppled at the canyon head, both of which can be estimated from field and remotely sensed data. Example applications on Earth and Mars show that our flood reconstructions yield canyon-carving discharges larger than inferred from incipient motion thresholds, and often dramatically smaller than inferred from assuming complete canyon inundation.
Research Topic | Research Site Name | NREL
exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Capabilities Width of 1746px - Height can , quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Subtopic Heading 2 ex ea commodo consequat. Publications Article Title, Journal Name (Year) Conference Paper Title
The effect of lane line width and contrast upon lanekeeping.
McKnight, A S; McKnight, A J; Tippetts, A S
1998-09-01
The combined effect of lane line width and line-pavement contrast upon lanekeeping was studied through simulation. Some 124 subjects, ages 17-79 (x = 56.30), 52% male, each performed 42 trials over road segments representing three levels of width crossed with 14 line-pavement contrast ratios. Lanekeeping performance was recorded in terms of heading error, position error, lane excursions and road excursions. Subjects were stratified into two levels of ability on a combined measure of visual, attentional and psychomotor variables known to decline with age. Contrast and width had a negligible effect upon performance except at very low contrast ratios, ca 1.02 at high pavement luminance levels (e.g. concrete) and 1.04 for very low luminance levels (e.g. asphalt). These ratios are similar to those encountered at night on wet roads. Mean overall performance error at the low contrast ratios increased by a factor of 1.6, 1.8 and 2.2 for 8, 6 and 4" widths, respectively. Lower ability subjects exhibited greater error at almost all contrast ratios, with no consistent relationship between degree of decrement and either width or contrast. The results suggest that lane line width and contrast have a negligible effect upon lanekeeping performance except at extremely low levels of contrast, where both have large effects. Further research in the roadway environment is needed to determine the relationships of line width and contrast ratio to lanekeeping on normal and degraded surface conditions.
A hybrid-drive nonisobaric-ignition scheme for inertial confinement fusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, X. T., E-mail: xthe@iapcm.ac.cn; Center for Applied Physics and Technology, HEDPS, Peking University, Beijing 100871; IFSA Collaborative Innovation Center of MoE, Shanghai Jiao-Tong University, Shanghai 200240
A new hybrid-drive (HD) nonisobaric ignition scheme of inertial confinement fusion (ICF) is proposed, in which a HD pressure to drive implosion dynamics increases via increasing density rather than temperature in the conventional indirect drive (ID) and direct drive (DD) approaches. In this HD (combination of ID and DD) scheme, an assembled target of a spherical hohlraum and a layered deuterium-tritium capsule inside is used. The ID lasers first drive the shock to perform a spherical symmetry implosion and produce a large-scale corona plasma. Then, the DD lasers, whose critical surface in ID corona plasma is far from the radiationmore » ablation front, drive a supersonic electron thermal wave, which slows down to a high-pressure electron compression wave, like a snowplow, piling up the corona plasma into high density and forming a HD pressurized plateau with a large width. The HD pressure is several times the conventional ID and DD ablation pressure and launches an enhanced precursor shock and a continuous compression wave, which give rise to the HD capsule implosion dynamics in a large implosion velocity. The hydrodynamic instabilities at imploding capsule interfaces are suppressed, and the continuous HD compression wave provides main pdV work large enough to hotspot, resulting in the HD nonisobaric ignition. The ignition condition and target design based on this scheme are given theoretically and by numerical simulations. It shows that the novel scheme can significantly suppress implosion asymmetry and hydrodynamic instabilities of current isobaric hotspot ignition design, and a high-gain ICF is promising.« less
Giant Occipitocervical Lipomas: Evaluation with Two Cases
Basmaci, Mehmet; Hasturk, Askin E
2012-01-01
Lipomas are capsulated benign tumours that are commonly found in all body parts. A lipoma is a well-defined mesenchymal tumour that arises from the adipose tissue. Although giant lipomas are rare in the head and neck regions, when they are located here, they are most commonly found in the subcutaneous posterior neck area. Recurrence as well as invasion is very rare after total surgical excision. In this article, we present two rare cases of giant lipomas in the posterior occipitocervical region, which is an exceptional location. PMID:23112521
[Proprioceptive sensitivity and orofacial functions].
Auriol, M; Coutand, A; Crinetz, V; Chomette, G; Doumit, A; Lucht, M
1985-01-01
Proprioceptive sensibility from stimulation of muscle, ligament articular and vestibular receptors plays a determining role in the regulation of tone, of the resting position of the mandible, of head posture and of the closure pathway of the mandible. Studies conducted on temporomandibular joints of fetuses and adult subjects failed to demonstrate the specialized corpuscles (a fact previously noted by Ramfjord) in the temporomaxillary joint capsule, described typically in other joints. In contrast, however, histology showed a particularly rich population of muscle receptors adjacent to this joint, this being only one of several particular characteristics.
2009-10-10
A Russian doctor monitors Expedition 20 Flight Engineer Michael Barratt onboard a helicopter heading to Kustanay, Kazakhstan shortly after Barratt, Expedition 20 Commander Gennady Padalka, and spaceflight participant Guy Laliberté landed their Soyuz TMA-14 capsule near the town of Arkalyk, Kazakhstan on Sunday, Oct. 11, 2009. Padalka and Barratt are returning from six months onboard the International Space Station, along with Laliberté who arrived at the station on Oct. 2 with Expedition 21 Flight Engineers Jeff Williams and Maxim Suraev aboard the Soyuz TMA-16 spacecraft. Photo Credit: (NASA/Bill Ingalls)
2009-10-10
Russian medical personnel monitor Expedition 20 Flight Engineer Michael Barratt onboard a helicopter heading to Kustanay, Kazakhstan shortly after Barratt, Expedition 20 Commander Gennady Padalka, and spaceflight participant Guy Laliberté landed their Soyuz TMA-14 capsule near the town of Arkalyk, Kazakhstan on Sunday, Oct. 11, 2009. Padalka and Barratt are returning from six months onboard the International Space Station, along with Laliberté who arrived at the station on Oct. 2 with Expedition 21 Flight Engineers Jeff Williams and Maxim Suraev aboard the Soyuz TMA-16 spacecraft. Photo Credit: (NASA/Bill Ingalls)
Nogal, Pawel; Pniewska-Siark, Barbara; Lewinski, Andrzej
2008-12-01
In patients with anorexia nervosa (AN), computer tomography (CT) scanning and/or magnetic resonance imaging (MR) are usually applied to visualise trophic changes of the brain, resulting from considerable malnutrition or general cachexia of the organism. The goal of the study was an evaluation attempt of the degree of trophic changes in the central nervous system (CNS) of girls with AN, following CT scanning of the brain, together with an analysis of selected clinical and diagnostic parameters, related to the trophic changes in question. The study involved fifty-five (55) female patients with AN. Following CT of the brain - scanning of the cortical sulci - four (4) groups of the patients were identified. The following classification of lesions was applied: Group I - width of cortical sulci < 1.5 mm - standard; Group II - the presence of cortical sulci of width < 1.5 mm and 1.5-3 mm; Group III - width of cortical sulci 1.5-3 mm; Group IV - the presence of cortical sulci of width at 1.5-3 mm and > 3 mm. We did not observe any patient with AN in whom the width of all the cortical sulci was bigger than 3 mm (Group V). In all the groups, clinical parameters, as well as routine laboratory tests and selected hormonal tests, were analysed. In the performed CT scanning of the head in patients with AN, trophic changes in the CNS (as evaluated by the width of cortical sulci) were revealed in 67.3% of the patients. Among the studied groups, statistically significant differences were found for: body weight loss (BWL), the percent of BWL (BWL%), the BWL to disease duration ratio (BWL/time) and BWL%/time, serum concentrations of potassium, calcium, glucose, total protein and urea, as well as serum concentrations of LH, E2, cortisol, FT3 and FT4. The most pronounced disturbances were observed in Group IV, while the least ones - in Group I. In CT scanning of the head, trophic changes in the CNS were observed in girls with AN, measured by the width of cortical sulci. The higher severity of trophic changes in the CNS was associated with higher BWL/time ratio, higher hypercortisolemia, more enhanced hypogonadotrophic hypogonadism, disorders in the peripheral metabolism of the thyroid hormones and with the obtained values of routine laboratory tests, indicating some tendency towards hypovolemia.
Janssen, A M; Rampersad, S M; Lucka, F; Lanfer, B; Lew, S; Aydin, Ü; Wolters, C H; Stegeman, D F; Oostendorp, T F
2013-01-01
Volume conduction models can help in acquiring knowledge about the distribution of the electric field induced by transcranial magnetic stimulation (TMS). One aspect of a detailed model is an accurate description of the cortical surface geometry. Since its estimation is difficult, it is important to know how accurate the geometry has to be represented. Previous studies only looked at the differences caused by neglecting the complete boundary between the CSF and GM (Thielscher et al. 2011; Bijsterbosch et al. 2012), or by resizing the whole brain (Wagner et al. 2008). However, due to the high conductive properties of the CSF, it can be expected that alterations in sulcus width can already have a significant effect on the distribution of the electric field. To answer this question, the sulcus width of a highly realistic head model, based on T1-, T2- and diffusion-weighted magnetic resonance images (MRI), was altered systematically. This study shows that alterations in the sulcus width do not cause large differences in the majority of the electric field values. However, considerable overestimation of sulcus width produces an overestimation of the calculated field strength, also at locations distant from the target location. PMID:23787706
High-speed fiber laser cutting of thick stainless steel for dismantling tasks
NASA Astrophysics Data System (ADS)
Shin, Jae Sung; Oh, Seong Yong; Park, Hyunmin; Chung, Chin-Man; Seon, Sangwoo; Kim, Taek-Soo; Lee, Lim; Choi, Byung-Seon; Moon, Jei-Kwon
2017-09-01
A high-speed fiber laser cutting technology of thick steels for dismantling tasks was achieved using a 6-kW fiber laser system. At first, a new cutting head for efficient cutting of thick steels was developed, which was composed by a collimator with a focal length of 160 mm and mirror-type focusing objects with a long focal length of 600 mm. The long focal length of the focusing object made it possible for the beam size to be small through the thick cutting material and the cutting efficiency was expected to increase compared with the short focal length. In addition, folding the beam facilitated the compact cutting head with a size of 160 mm (width) × 80 mm (height) × 640 mm (length) and a weight of 6.9 kg. In the cutting experiment, the laser beam was delivered to the cutting head by a 25-m long process fiber with a core diameter of 100 μm. The cutting performances were studied against the thicknesses of stainless steel plates. A maximum cutting speed of 72 mm/min was obtained for the 60-mm thick stainless steel plate cutting and the cut specimen showed an excellent kerf shape and a narrow kerf width. To the best of our knowledge, this cutting speed was higher than other previously reported results when cutting with a 6-kW laser power.
Liu, Yu; Maas, Andreas; Waloszek, Dieter
2010-09-01
We report our investigations on the embryonic development of Gryllus assimilis, with particular attention to the head. Significant findings revealed with scanning electron microscopy (SEM) images include: (1) the pre-antennal lobes represent the anterior-most segment that does not bear any appendages; (2) each of the lobes consists of central and marginal regions; (3) the central region thereof develops into the protocerebrum and the optic lobes, whereas the marginal region thereof becomes the anterior portion of the head capsule; (4) the initial position of the antennal segment is posterior to the mouth region; (5) appendage anlagen are transitorily present in the intercalary segment, and they later vanish together with the segment itself; (6) a bulged sternum appears to develop from the ventral surface of the mandibular, maxillary and labial segments. Embryonic features are then compared across the Insecta and further extended to the embryos of a spider (Araneae, Chelicerata). Striking similarities shared by the anterior-most region of the insect and spider embryos lead the authors to conclude that such comparison should be further undertaken to cover the entire Euarthropoda. This will help us to understand the embryology and evolution of the arthropod head. Copyright © 2010 Elsevier Ltd. All rights reserved.
A new species of Bolitoglossa (Amphibia, Caudata) from the Sierra de Juárez, Oaxaca, Mexico
Rovito, Sean M.; Parra-Olea, Gabriela; Lee, Dana; Wake, David B.
2012-01-01
Abstract We describe a new species of Bolitoglossa (Nanotriton) from the Sierra de Juárez and Sierra Mixe of Oaxaca, Mexico. Bolitoglossa chinanteca sp. n. is distinguished from the three other species in the subgenus Nanotriton by its more robust body, by having substantial numbers of maxillary teeth and differences in relative head width, foot width, and limb length. The new species occurs in sympatry with Bolitoglossa (Nanotriton) rufescens at the type locality. The description of another species of salamander from the Sierra de Juárez is noteworthy, given the already high plethodontid salamander species richness of the region. PMID:22577313
An integrated optical sensor for GMAW feedback control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, P.L.; Watkins, A.D.; Larsen, E.D.
1992-08-01
The integrated optical sensor (IOS) is a multifunction feedback control sensor for arc welding, that is computer automated and independent of significant operator interaction. It is based on three major ``off-the-shelf`` components: a charged coupled device (CCD) camera, a diode laser, and a processing computer. The sensor head is compact and lightweight to avoid interference with weld head mobility, hardened to survive the harsh operating environment, and free of specialized cooling and power requirements. The sensor is positioned behind the GMAW torch and measures weld pool position and width, standoff distance, and postweld centerline cooling rate. Weld pool position andmore » width are used in a feedback loop, by the weld controller, to track the weld pool relative to the weld joint, thus allowing compensation for such phenomena as arc blow. Sensor stand off distance is used in a feedback loop to control the contact tip to base metal distance during the welding process. Cooling rate information is used to infer the final metallurgical state of the weld bead and heat affected zone, thereby providing a means of controlling post weld mechanical properties.« less
An integrated optical sensor for GMAW feedback control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, P.L.; Watkins, A.D.; Larsen, E.D.
1992-01-01
The integrated optical sensor (IOS) is a multifunction feedback control sensor for arc welding, that is computer automated and independent of significant operator interaction. It is based on three major off-the-shelf'' components: a charged coupled device (CCD) camera, a diode laser, and a processing computer. The sensor head is compact and lightweight to avoid interference with weld head mobility, hardened to survive the harsh operating environment, and free of specialized cooling and power requirements. The sensor is positioned behind the GMAW torch and measures weld pool position and width, standoff distance, and postweld centerline cooling rate. Weld pool position andmore » width are used in a feedback loop, by the weld controller, to track the weld pool relative to the weld joint, thus allowing compensation for such phenomena as arc blow. Sensor stand off distance is used in a feedback loop to control the contact tip to base metal distance during the welding process. Cooling rate information is used to infer the final metallurgical state of the weld bead and heat affected zone, thereby providing a means of controlling post weld mechanical properties.« less
Alagboso, Francisca I; Reisecker, Christian; Hild, Sabine; Ziegler, Andreas
2014-08-01
The cuticle of the cornea in Crustacea is an interesting example of a composite material compromising between two distinct functions. As part of the dioptric apparatus of the ommatidia within the complex eye it forms transparent micro-lenses that should as well maintain the mechanical stability of the head capsule. We analyzed the ultrastructure and composition of the isopod cornea cuticle of the terrestrial species Ligia oceanica and the marine Sphaeroma serratum. We used a variety of tissue preparation methods, electron microscopic techniques as well as electron microprobe analysis and Raman spectroscopic imaging. The results reveal various structural adaptations that likely increase light transmission. These are an increase in the thickness of the epicuticle, a reduction of the thickness of the outer layer of calcite, a spatial restriction of pore canals to interommatidial regions, and, for S. serratum only, an increase in calcite crystal size. In both species protein-chitin fibrils within the proximal exocuticle form a peculiar reticular structure that does not occur within the cuticle of the head capsule. In L. oceanica differential mineralization results in a spherically shaped interface between mineralized and unmineralized endocuticle, likely an adaptation to increase the refractive power of the cornea maintaining the mechanical stability of the cuticle between the ommatidia. The results show that the habitat and differences in the general structure of the animal's cuticle affect the way in which the cornea is adapted to its optical function. Copyright © 2014 Elsevier Inc. All rights reserved.
Koutsarnakis, Christos; Liakos, Faidon; Kalyvas, Aristotelis V; Skandalakis, Georgios P; Komaitis, Spyros; Christidi, Fotini; Karavasilis, Efstratios; Liouta, Evangelia; Stranjalis, George
2017-10-01
To explore the superior frontal sulcus (SFS) morphology, trajectory of the applied surgical corridor, and white matter bundles that are traversed during the superior frontal transsulcal transventricular approach. Twenty normal, adult, formalin-fixed cerebral hemispheres and 2 cadaveric heads were included in the study. The topography, morphology, and dimensions of the SFS were recorded in all specimens. Fourteen hemispheres were investigated through the fiber dissection technique whereas the remaining 6 were explored using coronal cuts. The cadaveric heads were used to perform the superior frontal transsulcal transventricular approach. In addition, 2 healthy volunteers underwent diffusion tensor imaging and tractography reconstruction studies. The SFS was interrupted in 40% of the specimens studied and was always parallel to the interhemispheric fissure. The proximal 5 cm of the SFS (starting from the SFS precentral sulcus meeting point) were found to overlie the anterior ventricular system in all hemispheres. Five discrete white matter layers were identified en route to the anterior ventricular system (i.e., the arcuate fibers, the frontal aslant tract, the external capsule, internal capsule, and the callosal radiations). Diffusion tensor imaging studies confirmed the fiber tract architecture. When feasible, the superior frontal transsulcal transventricular approach offers a safe and effective corridor to the anterior part of the lateral ventricle because it minimizes brain retraction and transgression and offers a wide and straightforward working corridor. Meticulous preoperative planning coupled with a sound microneurosurgical technique are prerequisites to perform the approach successfully. Copyright © 2017 Elsevier Inc. All rights reserved.
Experience of disused source management in Latin America
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pimenta Mourao, R.
2008-07-01
The Centro de Desenvolvimento da Tecnologia Nuclear (Center for the Development of Nuclear Technology) - CDTN - has been actively engaged in cooperation programs for disused source management throughout the Latin American and the Caribbean region since 1996. The CDTN source conditioning team participated in the preparation of the technical procedures established for the different tasks involved in the radium sources conditioning operations, like preparation of the packaging for conditioning; sources conditioning; capsule welding; leak test in radium-containing capsule; and radiation protection planning for the conditioning of disused radium sources. The team also carried out twelve radium sources conditioning operationmore » in the region, besides in-house operations, which resulted in a total conditioned activity of approximately 525 GBq, or 14,200 mg of radium. Additionally, one operation was carried out in Nicaragua to safely condition three Cobalt teletherapy heads stored under very precarious conditions in the premises of an old hospital. More recently, the team started its participation in an IAEA- and US State Department-sponsored program for the repatriation of disused or excess transuranic sources presently stored at users' premises or under regulatory control in different countries in the region. In September 2007 the team attended a theoretical and practical training in transuranic sources management, including the participation in the conditioning of different neutron sources in certified packages. It is expected that the trained team will carry out similar operations in other Latin American countries. Finally, the team is expected be involved in the near future in the repatriation of US-origin teletherapy heads and industrial gauges. (authors)« less
Odeyemi, M O; Fasoranti, J O; Ande, A T; Olayemi, I K
2013-08-01
This study was aimed at generating baseline information for sustainable genetic improvement of Cirana forda larvae for entomophagy, through the use of gamma irradiation. Eggs of C. forda were irradiated with increasing doses of gamma rays from 0 to 200 Gy and raised through larval instal stages under laboratory conditions. The Body Weight (BW) and Head Capsule Width (HCW) of the larval instar stages were monitored as indices of productivity. Successful larval emergence was recorded for all irradiation doses tested and BW of the 1st and 2nd instar larvae were not significantly (p > 0.05) different between the control and treated groups (range = 0.021 +/- 0.003 g/larva in the 200 Gy treatment to 0.028 +/- 0.003 g/larva in the control group and 0.105 +/- 0.003 g/larva in 20 Gy treatment to 0.172 +/- 0.009 g/larva in the control group, respectively). On the other hand, BW during the 3rd and 4th larval instars were significantly (p < 0.05) lower among the irradiated treatments than control. Pattern of distribution of HCW was different from that of BW; as HCW increased with irradiation dose from 10-50 Gy during the 3rd and 4th larval instars. Also, HCW during the 5th instar larvae among the irradiated treatments (range = 5.256 +/- 0.012 to 5.662 +/- 0.026 mm) were not higher than that of the 6th instar in the control group (6.065 +/- 0.010 mm). These results suggest promising potentials of the use of gamma irradiation in sustainably improving the productivity of C. forda larvae for entomophagy.
Li, Qinglong; Yang, Mingsheng; Liu, Yunxiang; Wei, Cong
2015-01-01
The cicada Meimuna mongolica (Distant) (Hemiptera: Cicadidae) is one of the most important pests of economic forest in Guanzhong Plain of Shaanxi Province, China. Information about ecological characteristics and some sustainable control measures of this species is urgently required for its control. In this study, nymphal instars, morphological variation, vertical distribution, and population density in soil, and emergence phenology of nymphs of M. mongolica on three main host plants (Pinus tabuliformis Carr., Populus tomentosa Carr., and Pyrus xerophila Yü) were studied, based on combined morphological and molecular identification, investigation of the first-instar nymphs hatched from eggs and others excavated from soil, and investigation of exuviae in the adult emergence period. Five nymphal instars of M. mongolica were redetermined according to the distribution plots of the head capsule widths of the nymphs. Nymphs of third and fourth instars showed morphological variation, which is closely related to host-plant association. The mean densities of nymphs in soil under the three host plants were significantly different, indicating a distinct host preference. The nymphs could extend their distribution from the 0–10 cm soil layer to the 51–60 cm soil layer underground but not beyond 60 cm soil layer under all the three host plants. The 21–30 cm soil layer under all the three host plants has the highest nymphal population density. The sex ratio of the entire population was nearly 50:50, but males dominated in the early half of the duration of the emergence. These ecological characteristics of M. mongolica could provide important information for sustainable control measures.
Schaeffeler, Christoph; Waldt, Simone; Bauer, Jan S; Kirchhoff, Chlodwig; Haller, Bernhard; Schröder, Michael; Rummeny, Ernst J; Imhoff, Andreas B; Woertler, Klaus
2014-06-01
To evaluate diagnostic signs and measurements in the assessment of capsular redundancy in atraumatic multidirectional instability (MDI) of the shoulder on MR arthrography (MR-A) including abduction/external rotation (ABER) images. Twenty-one MR-A including ABER position of 20 patients with clinically diagnosed MDI and 17 patients without instability were assessed by three radiologists. On ABER images, presence of a layer of contrast between the humeral head (HH) and the anteroinferior glenohumeral ligament (AIGHL) (crescent sign) and a triangular-shaped space between the HH, AIGHL and glenoid (triangle sign) were evaluated; centring of the HH was measured. Anterosuperior herniation of the rotator interval (RI) capsule and glenoid version were determined on standard imaging planes. The crescent sign had a sensitivity of 57 %/62 %/48 % (observers 1/2/3) and specificity of 100 %/100 %/94 % in the diagnosis of MDI. The triangle sign had a sensitivity of 48 %/57 %/48 % and specificity of 94 %/94 %/100 %. The combination of both signs had a sensitivity of 86 %/90 %/81 % and specificity of 94 %/94 %/94 %. A positive triangle sign was significantly associated with decentring of the HH. Measurements of RI herniation, RI width and glenoid were not significantly different between both groups. Combined assessment of redundancy signs on ABER position MR-A allows for accurate differentiation between patients with atraumatic MDI and patients with clinically stable shoulders; measurements on standard imaging planes appear inappropriate. MR arthrography has the possibility to accurately identify patients with atraumatic MDI. Imaging of the shoulder in abduction and external rotation provides additive information. Capsular enlargement of the shoulder can be diagnosed on MR arthrography.
Innovative virtual reality measurements for embryonic growth and development.
Verwoerd-Dikkeboom, C M; Koning, A H J; Hop, W C; van der Spek, P J; Exalto, N; Steegers, E A P
2010-06-01
Innovative imaging techniques, using up-to-date ultrasonic equipment, necessitate specific biometry. The aim of our study was to test the possibility of detailed human embryonic biometry using a virtual reality (VR) technique. In a longitudinal study, three-dimensional (3D) measurements were performed from 6 to 14 weeks gestational age in 32 pregnancies (n = 16 spontaneous conception, n = 16 IVF/ICSI). A total of 125 3D volumes were analysed in the I-Space VR system, which allows binocular depth perception, providing a realistic 3D illusion. Crown-rump length (CRL), biparietal diameter (BPD), occipito-frontal diameter (OFD), head circumference (HC) and abdominal circumference (AC) were measured as well as arm length, shoulder width, elbow width, hip width and knee width. CRL, BPD, OFD and HC could be measured in more than 96% of patients, and AC in 78%. Shoulder width, elbow width, hip width and knee width could be measured in more than 95% of cases, and arm length in 82% of cases. Growth curves were constructed for all variables. Ear and foot measurements were only possible beyond 9 weeks gestation. This study provides a detailed, longitudinal description of normal human embryonic growth, facilitated by a VR system. Growth curves were created for embryonic biometry of the CRL, BPD, HC and AC early in pregnancy and also of several 'new' biometric measurements. Applying virtual embryoscopy will enable us to diagnose growth and/or developmental delay earlier and more accurately. This is especially important for pregnancies at risk of severe complications, such as recurrent late miscarriage and early growth restriction.
Shariat-Mohaymany, Afshin; Tavakoli-Kashani, Ali; Nosrati, Hadi; Ranjbari, Andisheh
2011-12-01
To identify the significant factors that influence head-on conflicts resulting from dangerous overtaking maneuvers on 2-lane rural roads in Iran. A traffic conflict technique was applied to 12 two-lane rural roads in order to investigate the potential situations for accidents to occur and thus to identify the geometric and traffic factors affecting traffic conflicts. Traffic data were collected via the inductive loop detectors installed on these roads, and geometric characteristics were obtained through field observations. Two groups of data were then analyzed independently by Pearson's chi-square test to evaluate their relationship to traffic conflicts. The independent variables were percentage of time spent following (PTSF), percentage of heavy vehicles, directional distribution of traffic (DDT), mean speed, speed standard deviation, section type, road width, longitudinal slope, holiday or workday, and lighting condition. It was indicated that increasing the PTSF, decreasing the percentage of heavy vehicles, increasing the mean speed (up to 75 km/h), increasing DDT in the range of 0 to 60 percent, and decreasing the standard deviation of speed significantly increased the occurrence of traffic conflicts. It was also revealed that traffic conflicts occur more frequently on curve sections and on workdays. The variables road width, slope, and lighting condition were found to have a minor effect on conflict occurrence. To reduce the number of head-on conflicts on the aforementioned roads, some remedial measures are suggested, such as not constructing long "No Passing" zones and constructing passing lanes where necessary; keeping road width at the standard value; constructing roads with horizontal curves and a high radius and using appropriate road markings and overtaking-forbidden signs where it is impossible to modify the radius; providing enough light and installing caution signs/devices on the roads; and intensifying police control and supervision on workdays, especially in peak hours.
Lavore, Andrés; Pagola, Lucía; Esponda-Behrens, Natalia; Rivera-Pomar, Rolando
2012-01-01
The segmentation process in insects depends on a hierarchical cascade of gene activity. The first effectors downstream of the maternal activation are the gap genes, which divide the embryo in broad fields. We discovered a sequence corresponding to the leucine-zipper domain of the orthologue of the gene giant (Rp-gt) in traces from the genome of Rhodnius prolixus, a hemipteran with intermediate germ-band development. We cloned the Rp-gt gene from a normalized cDNA library and characterized its expression and function. Bioinformatic analysis of 12.5 kbp of genomic sequence containing the Rp-gt transcriptional unit shows a cluster of bona fide regulatory binding sites, which is similar in location and structure to the predicted posterior expression domain of the Drosophila orthologue. Rp-gt is expressed in ovaries and maternally supplied in the early embryo. The maternal contribution forms a gradient of scattered patches of mRNA in the preblastoderm embryo. Zygotic Rp-gt is expressed in two domains that after germ band extension are restricted to the head and the posterior growth zone. Parental RNAi shows that Rp-gt is required for proper head and abdomen formation. The head lacks mandibulary and maxillary appendages and shows reduced clypeus-labrum, while the abdomen lacks anterior segments. We conclude that Rp-gt is a gap gene on the head and abdomen and, in addition, has a function in patterning the anterior head capsule suggesting that the function of gt in hemipterans is more similar to dipterans than expected. Copyright © 2011. Published by Elsevier Inc.
Lorenz, Jonas; Blume, Maximilian; Barbeck, Mike; Teiler, Anna; Kirkpatrick, C James; Sader, Robert A; Ghanaati, Shahram
2017-05-01
Attached peri-implant gingiva has proven to have an influence on the long-term stability of dental implants. In patients with head and neck cancer, a functional peri-implant gingiva is even more of critical importance. The aim of the presented prospective study was to investigate a three-dimensional xenogeneic collagen matrix for augmentation around dental implants in patients with former head and neck cancer. Eight patients presenting with insufficient peri-implant gingiva underwent vestibuloplasty on 51 implants using a xenogeneic collagen matrix. The clinical performance and the shrinking tendency of the matrix were analyzed in a cohort study. Furthermore, eight biopsies from the augmented regions were examined histologically to determine the biomaterial-related tissue reaction. Initially after vestibuloplasty, a mean width of attached gingiva of 4.4 ± 0.94 mm could be achieved. At clinical follow up investigation 6 months after vestibuloplasty, a mean width of 3.9 ± 0.65 mm attached peri-implant gingiva with a mean shrinking tendency of 14 % could be detected. Histological analysis of the biopsies revealed a well integrated collagen22 matrix covered with epithelium. Within the compact layer, mononuclear cells were observed only, while the spongious layer was infiltrated with a cell-rich connective tissue. Within its limits, the presented study revealed that the investigated collagen matrix is suitable to enlarge the peri-implant attached gingiva in head and neck cancer patients without adverse reactions or a multinucleated giant cell-triggered tissue reaction. The application of the investigated three-dimensional collagen matrix in vestibuloplasty achieved a sufficient amount of peri-implant attached gingiva in head and neck cancer patients. The favorable tissue reaction and the low shrinking tendency make the collagen matrix a promising alternative to autologous tissue grafts.
2008-04-01
A full-scale flight-test mockup of the Constellation program's Orion crew vehicle arrived at NASA's Dryden Flight Research Center in late March 2008 to undergo preparations for the first short-range flight test of the spacecraft's astronaut escape system later that year. Engineers and technicians at NASA's Langley Research Center fabricated the structure, which precisely represents the size, outer shape and mass characteristics of the Orion space capsule. The Orion crew module mockup was ferried to NASA Dryden on an Air Force C-17. After painting in the Edwards Air Force Base paint hangar, the conical capsule was taken to Dryden for installation of flight computers, instrumentation and other electronics prior to being sent to the U.S. Army's White Sands Missile Range in New Mexico for integration with the escape system and the first abort flight test in late 2008. The tests were designed to ensure a safe, reliable method of escape for astronauts in case of an emergency.
2008-01-01
Background Sperm morphology can be highly variable among species, but less is known about patterns of population differentiation within species. Most studies of sperm morphometric variation are done in species with internal fertilization, where sexual selection can be mediated by complex mating behavior and the environment of the female reproductive tract. Far less is known about patterns of sperm evolution in broadcast spawners, where reproductive dynamics are largely carried out at the gametic level. We investigated variation in sperm morphology of a broadcast spawner, the green sea urchin (Strongylocentrotus droebachiensis), within and among spawnings of an individual, among individuals within a population, and among populations. We also examined population-level variation between two reproductive seasons for one population. We then compared among-population quantitative genetic divergence (QST) for sperm characters to divergence at neutral microsatellite markers (FST). Results All sperm traits except total length showed strong patterns of high diversity among populations, as did overall sperm morphology quantified using multivariate analysis. We also found significant differences in almost all traits among individuals in all populations. Head length, axoneme length, and total length had high within-male repeatability across multiple spawnings. Only sperm head width had significant within-population variation across two reproductive seasons. We found signatures of directional selection on head length and head width, with strong selection possibly acting on head length between the Pacific and West Atlantic populations. We also discuss the strengths and limitations of the QST-FST comparison. Conclusion Sperm morphology in S. droebachiensis is highly variable, both among populations and among individuals within populations, and has low variation within an individual across multiple spawnings. Selective pressures acting among populations may differ from those acting within, with directional selection implicated in driving divergence among populations and balancing selection as a possible mechanism for producing variability among males. Sexual selection in broadcast spawners may be mediated by different processes from those acting on internal fertilizers. Selective divergence in sperm head length among populations is associated with ecological differences among populations that may play a large role in mediating sexual selection in this broadcast spawner. PMID:18851755
Heads, Sam W; Penney, David; Green, David I
2012-01-01
A new species of the cricket genus Proanaxipha Vickery & Poinar (Orthoptera: Gryllidae: Pentacentrinae) from Early Miocene Dominican amber is described and illustrated. Proanaxipha madgesuttonaesp. n. is distinguished from congeners by: (1) head capsule bearing a distinctive posteriorly bilobed colour spot on the vertex; (2) presence of crossveins in the proximal part of the mediocubital area; (3) apical field of tegmen entirely dark; and (4) median process of epiphallus short. The poorly known Proanaxipha bicolorata Vickery & Poinar, of questionable affinity and status, is herein regarded as a nomen inquirendum.
Heads, Sam W.; Penney, David; Green, David I.
2012-01-01
Abstract A new species of the cricket genus Proanaxipha Vickery & Poinar (Orthoptera: Gryllidae: Pentacentrinae) from Early Miocene Dominican amber is described and illustrated. Proanaxipha madgesuttonae sp. n. is distinguished from congeners by: (1) head capsule bearing a distinctive posteriorly bilobed colour spot on the vertex; (2) presence of crossveins in the proximal part of the mediocubital area; (3) apical field of tegmen entirely dark; and (4) median process of epiphallus short. The poorly known Proanaxipha bicolorata Vickery & Poinar, of questionable affinity and status, is herein regarded as a nomen inquirendum. PMID:23166475
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-07
... surface for press printing, and/or wear protection for the thermal print head. \\5\\ HTSUS subheading 4811... 1, 2005. Effective that date, subheading 4811.90.9000 was replaced with 4811.90.9010 (for tissue..., (8) color coating, (9) printing, (10) width, (11) length, and (12) core material. Where there were no...
Development of Independent Locomotion in Children with a Severe Visual Impairment
ERIC Educational Resources Information Center
Hallemans, Ann; Ortibus, Els; Truijen, Steven; Meire, Francoise
2011-01-01
Locomotion of children and adults with a visual impairment (ages 1-44, n = 28) was compared to that of age-related individuals with normal vision (n = 60). Participants walked barefoot at preferred speed while their gait was recorded by a Vicon[R] system. Walking speed, heading angle, step frequency, stride length, step width, stance phase…
The Organization of Exploratory Behaviors in Infant Locomotor Planning
ERIC Educational Resources Information Center
Kretch, Kari S.; Adolph, Karen E.
2017-01-01
How do infants plan and guide locomotion under challenging conditions? This experiment investigated the real-time process of visual and haptic exploration in 14-month-old infants as they decided whether and how to walk over challenging terrain--a series of bridges varying in width. Infants' direction of gaze was recorded with a head-mounted eye…
[Glaucoma and optic nerve drusen: Limitations of optic nerve head OCT].
Poli, M; Colange, J; Goutagny, B; Sellem, E
2017-09-01
Optic nerve head drusen are congenital calcium deposits located in the prelaminar section of the optic nerve head. Their association with visual field defects has been classically described, but the diagnosis of glaucoma is not easy in these cases of altered optic nerve head anatomy. We describe the case of a 67-year-old man with optic nerve head drusen complicated by glaucoma, which was confirmed by visual field and OCT examination of the peripapillary retinal nerve fiber layer (RNFL), but the measurement of the minimum distance between the Bruch membrane opening and the internal limiting membrane (minimum rim width, BMO-MRW) by OCT was normal. OCT of the BMO-MRW is a new diagnostic tool for glaucoma. Superficial optic nerve head drusen, which are found between the internal limiting membrane and the Bruch's membrane opening, overestimate the value of this parameter. BMO-MRW measurement is not adapted to cases of optic nerve head drusen and can cause false-negative results for this parameter, and the diagnosis of glaucoma in this case should be based on other parameters such as the presence of a fascicular defect in the retinal nerve fibers, RNFL or macular ganglion cell complex thinning, as well as visual field data. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Janssen, A. M.; Rampersad, S. M.; Lucka, F.; Lanfer, B.; Lew, S.; Aydin, Ü.; Wolters, C. H.; Stegeman, D. F.; Oostendorp, T. F.
2013-07-01
Volume conduction models can help in acquiring knowledge about the distribution of the electric field induced by transcranial magnetic stimulation. One aspect of a detailed model is an accurate description of the cortical surface geometry. Since its estimation is difficult, it is important to know how accurate the geometry has to be represented. Previous studies only looked at the differences caused by neglecting the complete boundary between cerebrospinal fluid (CSF) and grey matter (Thielscher et al 2011 NeuroImage 54 234-43, Bijsterbosch et al 2012 Med. Biol. Eng. Comput. 50 671-81), or by resizing the whole brain (Wagner et al 2008 Exp. Brain Res. 186 539-50). However, due to the high conductive properties of the CSF, it can be expected that alterations in sulcus width can already have a significant effect on the distribution of the electric field. To answer this question, the sulcus width of a highly realistic head model, based on T1-, T2- and diffusion-weighted magnetic resonance images, was altered systematically. This study shows that alterations in the sulcus width do not cause large differences in the majority of the electric field values. However, considerable overestimation of sulcus width produces an overestimation of the calculated field strength, also at locations distant from the target location.
Micromagnetic recording model of writer geometry effects at skew
NASA Astrophysics Data System (ADS)
Plumer, M. L.; Bozeman, S.; van Ek, J.; Michel, R. P.
2006-04-01
The effects of the pole-tip geometry at the air-bearing surface on perpendicular recording at a skew angle are examined through modeling and spin-stand test data. Head fields generated by the finite element method were used to record transitions within our previously described micromagnetic recording model. Write-field contours for a variety of square, rectangular, and trapezoidal pole shapes were evaluated to determine the impact of geometry on field contours. Comparing results for recorded track width, transition width, and media signal to noise ratio at 0° and 15° skew demonstrate the benefits of trapezoidal and reduced aspect-ratio pole shapes. Consistency between these modeled results and test data is demonstrated.
Spatial calibration of an optical see-through head mounted display
Gilson, Stuart J.; Fitzgibbon, Andrew W.; Glennerster, Andrew
2010-01-01
We present here a method for calibrating an optical see-through Head Mounted Display (HMD) using techniques usually applied to camera calibration (photogrammetry). Using a camera placed inside the HMD to take pictures simultaneously of a tracked object and features in the HMD display, we could exploit established camera calibration techniques to recover both the intrinsic and extrinsic properties of the HMD (width, height, focal length, optic centre and principal ray of the display). Our method gives low re-projection errors and, unlike existing methods, involves no time-consuming and error-prone human measurements, nor any prior estimates about the HMD geometry. PMID:18599125
Life Cycle and Immature Stages of the Arctiid Moth, Phoenicoprocta capistrata
Rodríguez-Loeches, Laura; Barro, Alejandro
2008-01-01
Phoenicoprocta capistrata (Fabricius 1775) (Lepidoptera: Arctiidae) is an arctiid moth reported for the Caribbean and Brazil, whose immature stages and life cycle are unknown. In this study, and for the first time, a host plant is registered and the immature stages and the captivity life cycle are described using a Cuban population. Larvae feed on fowlsfoot, Serjania diversifolia (Jacq.) Radlk (Sapindales: Sapindaceae). One complete cohort was obtained from December of 2004 to February of 2005 and about 57 days lapsed from oviposition to adult emergence. The egg is light green-yellowish and semi-spherical. Most larvae developed through 6 or 7 instars, although there were individuals with 8 instars. The last instar has a cephalic capsule width of 2.04 ± 0.06 mm (n = 29) irrespective of the number of instars. The cephalic capsule growth curves of the larvae with 6 and 7 instars have different slopes, but both follow a geometric pattern consistent with the Dyar's rule. In each larval molt the setae types and the larvae coloration change. Adult females have two color morphs, one orange-reddish and the other blue. Female descendants of blue and red females differ in the proportion of color morphs, which could indicate the existence of a female-limited polymorphism phenomenon in this species. PMID:20345309
Research on driver fatigue detection
NASA Astrophysics Data System (ADS)
Zhang, Ting; Chen, Zhong; Ouyang, Chao
2018-03-01
Driver fatigue is one of the main causes of frequent traffic accidents. In this case, driver fatigue detection system has very important significance in avoiding traffic accidents. This paper presents a real-time method based on fusion of multiple facial features, including eye closure, yawn and head movement. The eye state is classified as being open or closed by a linear SVM classifier trained using HOG features of the detected eye. The mouth state is determined according to the width-height ratio of the mouth. The head movement is detected by head pitch angle calculated by facial landmark. The driver's fatigue state can be reasoned by the model trained by above features. According to experimental results, drive fatigue detection obtains an excellent performance. It indicates that the developed method is valuable for the application of avoiding traffic accidents caused by driver's fatigue.
Human recognition based on head-shoulder contour extraction and BP neural network
NASA Astrophysics Data System (ADS)
Kong, Xiao-fang; Wang, Xiu-qin; Gu, Guohua; Chen, Qian; Qian, Wei-xian
2014-11-01
In practical application scenarios like video surveillance and human-computer interaction, human body movements are uncertain because the human body is a non-rigid object. Based on the fact that the head-shoulder part of human body can be less affected by the movement, and will seldom be obscured by other objects, in human detection and recognition, a head-shoulder model with its stable characteristics can be applied as a detection feature to describe the human body. In order to extract the head-shoulder contour accurately, a head-shoulder model establish method with combination of edge detection and the mean-shift algorithm in image clustering has been proposed in this paper. First, an adaptive method of mixture Gaussian background update has been used to extract targets from the video sequence. Second, edge detection has been used to extract the contour of moving objects, and the mean-shift algorithm has been combined to cluster parts of target's contour. Third, the head-shoulder model can be established, according to the width and height ratio of human head-shoulder combined with the projection histogram of the binary image, and the eigenvectors of the head-shoulder contour can be acquired. Finally, the relationship between head-shoulder contour eigenvectors and the moving objects will be formed by the training of back-propagation (BP) neural network classifier, and the human head-shoulder model can be clustered for human detection and recognition. Experiments have shown that the method combined with edge detection and mean-shift algorithm proposed in this paper can extract the complete head-shoulder contour, with low calculating complexity and high efficiency.
Oshita, Jumpei; Ohba, Shinji; Itou, Yoko; Yonezawa, Koki; Hosogai, Masahiro
2017-10-01
An 81-year-old man presented with gait disturbance. Two months previously, he suffered from hepatocellular carcinoma and transarterial chemoembolization was performed. A head computed tomography(CT)scan revealed bilateral chronic subdural hematomas. The patient's gait disturbance was improved after achievement of bilateral burr hole drainage. A head CT two months after treatment revealed no recurrence of the hematomas. However, head CT images obtained four months after treatment revealed an abnormal mass in the right parietal region attached to the internal surface of the skull. The mass was located in the same region from where the chronic subdural hematomas were previously removed via burr hole drainage, and was suspected to have originated from the dura mater. We performed craniotomy and total removal of the mass. The dura mater was intact, and macroscopically, the mass originated from the organized membrane of the chronic subdural hematoma. A pathological examination revealed metastasis of hepatocellular carcinoma to the membrane of the chronic subdural hematomas. Head magnetic resonance imaging(MRI)performed 39 days after craniotomy presented a new lesion in the left parietal region attached to the internal surface of the skull. The patient subsequently died 46 days post-operation. When examining chronic subdural hematomas in cancer patients, histological examination of the dura mater, hematoma, and membrane of the hematoma are important. The possibility of metastasis to the capsule of the hematoma should be considered.
Monensin controlled-release intraruminal capsule for control of bloat in pastured dairy cows.
Lowe, L B; Ball, G J; Carruthers, V R; Dobos, R C; Lynch, G A; Moate, P J; Poole, P R; Valentine, S C
1991-01-01
Monensin, a polyether ionophore antibiotic, is potentially an important agent for bloat relief in dairy cows grazing temperate legume-based pasture. A series of studies was undertaken to determine the effect of monensin, when delivered continuously in the rumen of lactating dairy cows by means of controlled-release capsules (monensin CRC). Such devices release approximately 300 mg/head/day for 100 d. A short-term pilot study made at Ruakura, New Zealand, tested monensin CRC in cows selected for high susceptibility to bloat and grazing lucerne (Medicago sativa) or red clover (Trifolium pratense). Treatment significantly reduced the incidence of bloat, while milk yield and protein yield were increased. There was no effect on fat yield. Following the pilot study, 6 large-scale field experiments involving a total of 368 lactating dairy cows, were made in Australia and New Zealand to confirm the effectiveness of monensin CRC for bloat control and to measure the effect of such treatment on milk production and composition. A severe bloat problem occurred in 2 experiments, mild bloat occurred in 2 others, while no visual signs of bloat were observed in the remaining 2 experiments. Bloat was significantly (P less than 0.05) reduced by monensin CRC treatment when data was pooled over the 4 experiments in which bloat occurred. Daily milk yield was increased in all experiments from a mean of 17.7 in untreated groups to 18.8 kg/head/day (P less than 0.05) in monensin CRC-treated cows. Protein percentage was not affected by treatment, while there was a decrease from 4.29 to 4.10% fat, although total fat yield was not affected.(ABSTRACT TRUNCATED AT 250 WORDS)
NASA Astrophysics Data System (ADS)
Lasher, G. E.; Axford, Y.; Blair, N. E.
2017-12-01
Oxygen isotopes measured in subfossil chironomid head capsules (aquatic insect remains) in lake sediments are beginning to offer paleoclimate insights from previously under-studied areas of the world. Since the first published pilot study demonstrated the potential of chironomid δ18O to record lake water δ18O (Wooller et al., 2004), subsequent work has refined our understanding of this proxy: confirming via lab cultures that growth water controls head capsule δ18O (Wang et al., 2009), refining laboratory pretreatment protocols, and further validating the method by demonstrating strong agreement between carbonate and chironomid-derived paleo-isotope records (Verbruggen et al., 2009, 2010, 2011). However, outstanding questions remain, including the seasonality of chironomid growth, possible species-dependent vital effects, and diagenetic effects on the protein-chitin complex that comprise chironomid cuticles. To address some of these questions, we summarize available data from paired modern chironomid-lake water δ18O values from around the world and discuss climatic and environmental factors affecting chironomid isotopic signatures. We also present new data on the resistance of these subfossils to diagenesis and degradation throughout the late Quaternary using Fourier Transform Infrared Spectroscopy (FT-IR) and Pyrolysis Gas Chromatography Mass Spectrometry (Py-GC/MS) of chironomid remains up to >100,000 years old. As chironomids are nearly ubiquitous in lakes globally and, we argue, molecularly stable through glacial and interglacial cycles, this proxy has the potential to greatly expand the spatial and temporal resolution of Quaternary paleo-isotopes and thus climate records. In addition to reviewing and presenting new methodological advances, we also present applications of chironomid δ18O from millennial- to centennial-scale Holocene Greenland lake records.
NASA Astrophysics Data System (ADS)
Muscedere, Mario L.; Traniello, James F. A.; Gronenberg, Wulfila
2011-09-01
Although several neurobiological and genetic correlates of aging and behavioral development have been identified in social insect workers, little is known about how other age-related physiological processes, such as muscle maturation, contribute to task performance. We examined post-eclosion growth of three major muscles of the head capsule in major and minor workers of the ant Pheidole dentata using workers of different ages with distinct task repertoires. Mandible closer muscle fibers, which provide bite force and are thus critical for the use of the mandibles for biting and load carrying, fill the posterio-lateral portions of the head capsule in mature, older workers of both subcastes. Mandible closer fibers of newly eclosed workers, in contrast, are significantly thinner in both subcastes and grow during at least the next 6 days in minor workers, suggesting this muscle has reduced functionality for a substantial period of adult life and thus constrains task performance capability. Fibers of the antennal muscles and the pharynx dilator, which control antennal movements and food intake, respectively, also increase significantly in thickness with age. However, these fibers are only slightly thinner in newly eclosed workers and attain their maximum thickness over a shorter time span in minors. The different growth rates of these functionally distinct muscles likely have consequences for how adult P. dentata workers, particularly minors, develop their full and diverse task repertoire as they age. Workers may be capable of feeding and interacting socially soon after eclosion, but require a longer period of development to effectively use their mandibles, which enable the efficient performance of tasks ranging from nursing to foraging and defense.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zamora, D; Moirano, J; Kanal, K
Purpose: A fundamental measure performed during an annual physics CT evaluation confirms that system displayed CTDIvol nearly matches the independently measured value in phantom. For wide-beam (z-direction) CT scanners, AAPM Report 111 defined an ideal measurement method; however, the method often lacks practicality. The purpose of this preliminary study is to develop a set of conversion factors for a wide-beam CT scanner, relating the CTDIvol measured with a conventional setup (single CTDI phantom) versus the AAPM Report 111 approach (three abutting CTDI phantoms). Methods: For both the body CTDI and head CTDI, two acquisition setups were used: A) conventional singlemore » phantom and B) triple phantom. Of primary concern were the larger nominal beam widths for which a standard CTDI phantom setup would not provide adequate scatter conditions. Nominal beam width (160 or 120 mm) and kVp (100, 120, 140) were modulated based on the underlying clinical protocol. Exposure measurements were taken using a CT pencil ion chamber in the center and 12 o’clock position, and CTDIvol was calculated with ‘nT’ limited to 100 mm. A conversion factor (CF) was calculated as the ratio of CTDIvol measured in setup B versus setup A. Results: For body CTDI, the CF ranged from 1.04 up to 1.10, indicating a 4–10% difference between usage of one and three phantoms. For a nominal beam width of 160 mm, the CF did vary with selected kVp. For head CTDI at nominal beam widths of 120 and 160 mm, the CF was 1.00 and 1.05, respectively, independent of the kVp used (100, 120, and 140). Conclusions: A clear understanding of the manufacturer method of estimating the displayed CTDIvol is important when interpreting annual test results, as the acquisition setup may lead to an error of up to 10%. With appropriately defined CF, single phantom use is feasible.« less
Effect of occlusal vertical dimension on lip positions at smile.
Chou, Jang-Ching; Thompson, Geoffrey A; Aggarwal, Harshit A; Bosio, Jose A; Irelan, Jon P
2014-09-01
In complete mouth reconstructive dentistry, the occlusal vertical dimension may be increased to provide adequate restorative space or to improve esthetics. The effect of increasing the occlusal vertical dimension on the smile is not well understood. The purpose of this study was to evaluate the effect of increasing the occlusal vertical dimension on the dimensions of the smile. Thirty dental students, 12 men and 18 women between the ages of 21 and 30 years old, participated in this study. Polyvinyl siloxane occlusal registrations 2, 4, 6, and 8 mm in thickness were fabricated from articulated stone casts. Posed smile images at occlusal vertical dimension +0, +2, +4, +6, and +8 mm were made with a digital single lens reflex camera mounted on a tripod. A wall-mounted head-positioning device, modified from a cephalometric unit, was used to stabilize the head position. Interlabial gap height, intercommissural width, incisal edge to upper lip, and incisal edge-to-lower lip measurements were made with computer software. The smile index was obtained by dividing width by height. The display zone area was measured by using computer software tracing. One-way repeated measures ANOVA (α=.05) was used for statistical analysis. With an increase in the occlusal vertical dimension, the interlabial gap height, incisal edge to lower lip distance, and display zone area increased significantly (P<.001), whereas the smile index decreased significantly (P<.001). No significant changes were observed in the intercommissural width and incisal edge to upper lip distance. The interlabial gap height, incisal edge-to-lower lip distance, and display zone area increase with increased occlusal vertical dimension. The smile index decreases with increased occlusal vertical dimension. However, the width of the smile and the length of the upper lip tend to remain unchanged. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
The origins of radial fracture systems and associated large lava flows on Venus
NASA Technical Reports Server (NTRS)
Parfitt, Elisabeth A.; Wilson, Lionel; Head, James W., III
1992-01-01
Magellan images have revealed the existence of systems of radial fractures on venus that are very similar in form to terrestrial dike swarms such as the Mackenzie swarm in Northern Canada. The association of many of the fracture systems with lava flows, calderas, and volcanic edifices further support the idea of a dike emplacement origin. A global survey of the Magellan images has allowed the location of 300 such fracture systems. Two types of fracture systems are defined. A series of models were developed to simulate the emplacement of dikes on Venus. Observations of fracture lengths and widths were then used to constrain the emplacement conditions. The model results show that the great length and relatively large width of the fractures can only be explained if the dikes that produce them were emplaced in high driving pressure (pressure buffered) conditions. Such conditions imply high rates of melt production, which is consistent with the melt being derived directly from a plume head. We have recently modeled the vertical emplacement of a dike from the top of a mantle plume and calculated the eruption rates such a dike would produce on reaching the surface. This modeling shows that eruption rates of approximately 0.1 cu km/hr can readily be generated by such a dike, consistent with the above results. However, the sensitivity of the model to dike width and therefore driving pressure means that eruption rates from dikes emplaced from the base of the crust or the head of a mantle plume could be orders of magnitude higher than this. Clearly, therefore, the model needs to be refined in order to better constrain eruption conditions. However, it is worth noting here that the initial results do show that even for moderate dike widths, eruption rates could be at least on the order of those estimated for terrestrial flood basalts.
Qiu, Xianjin; Gong, Rong; Tan, Youbin; Yu, Sibin
2012-12-01
Seed shape in rice (Oryza sativa) is an important factor that determines grain appearance, cooking quality and grain yield. Here, we report a major quantitative trait locus qSS7 on the long arm of chromosome 7 for seed length, seed width and the ratio of seed length to width, identified using a segregating population derived from a cross between an indica variety Zhenshan97 and a chromosomal segment substitution line of a japonica variety Cypress within the genetic background of Zhenshan97. The Cypress allele at qSS7 contributes to an increase in seed length and the ratio of length to width, but a decrease in seed width, without significantly changing seed weight, plant height, heading date or number of spikelets per panicle. Using a large F(2) population generated from a substitution line that carries only a heterozygous single segment surrounding qSS7, we delimited the QTL to a 23-kb region containing two annotated genes. Progeny testing of the informative recombinants suggested that this qSS7 region is a composite QTL in which at least two genes contribute to seed length and width. Sequence comparison and expression analysis of two probable candidate genes revealed differences between the parental lines. These results will facilitate cloning of the gene(s) underlying qSS7 as well as marker-assisted transfer of desirable genes for seed shape in rice improvement.
Eye structure and amphibious foraging in albatrosses
Martin, G. R.
1998-01-01
Anterior eye structure and retinal visual fields were determined in grey-headed and black-browed albatrosses, Diomedea melanophris and D. chrysostoma (Procellariiformes, Diomedeidae), using keratometry and an ophthalmoscopic reflex technique. Results for the two species were very similar and indicate that the eyes are of an amphibious optical design suggesting that albatross vision is well suited to the visual pursuit of active prey both on and below the ocean surface. The corneas are relatively flat (radius ca. 14.5 mm) and hence of low absolute refractive power (ca. 23 dioptres). In air the binocular fields are relatively long (vertical extent ca. 70 degrees) and narrow (maximum width in the plane of the optic axes 26–32 degrees), a topography found in a range of bird species that employ visual guidance of bill position when foraging. The cyclopean fields measure approximately 270 degrees in the horizontal plane, but there is a 60 degrees blind sector above the head owing to the positioning of the eyes below the protruding supraorbital ridges. Upon immersion the monocular fields decrease in width such that the binocular fields are abolished. Anterior eye structure, and visual field topography in both air and water, show marked similarity with those of the Humboldt penguin.
Ye, Weimin; Robbins, R. T.
2004-01-01
Hierarchical cluster analysis based on female morphometric character means including body length, distance from vulva opening to anterior end, head width, odontostyle length, esophagus length, body width, tail length, and tail width were used to examine the morphometric relationships and create dendrograms for (i) 62 populations belonging to 9 Longidorus species from Arkansas, (ii) 137 published Longidorus species, and (iii) 137 published Longidorus species plus 86 populations of 16 Longidorus species from Arkansas and various other locations by using JMP 4.02 software (SAS Institute, Cary, NC). Cluster analysis dendograms visually illustrated the grouping and morphometric relationships of the species and populations. It provided a computerized statistical approach to assist by helping to identify and distinguish species, by indicating morphometric relationships among species, and by assisting with new species diagnosis. The preliminary species identification can be accomplished by running cluster analysis for unknown species together with the data matrix of known published Longidorus species. PMID:19262809
Espelt, Mónica; Aragay, Gemma; Ballester, Pablo
2015-01-01
The encapsulation of N,N, N',N'-tetramethyl-1,5-pentanediamine-N,N'-dioxide 2 in a non-chiral capsular assembly formed by dimerization of tetraurea-calix[4]pyrrole 1a produced the observation of the N-methyl groups of the encapsulated guest as two separated singlets resonating highly upfield in the (1)H NMR spectrum. In order to clarify the origin of the observed signal splitting we assembled and studied a series of structurally related dimeric capsules. We used the tetraurea-calix[4]pyrrole 1a , the enantiomerically pure tetraurea-calix[4] pyrrole R-1b and the tetraurea-bisloop calix[4]pyrrole 1c as components of the produced assemblies. The (1)H NMR spectra of the assembled encapsulation complexes with bis-N-oxide 2 evidenced diverse splitting patterns of the N-methyl groups. In addition, 2D EXSY/ROESY NMR experiments revealed the existence of chemical exchange processes involving the separated methyl signals of the encapsulated guest. The capsular assemblies were mainly stabilized by a belt of eight head-to-tail hydrogen-bonded urea groups. The interconversion between the two senses of rotation of the unidirectionally oriented urea groups was slow on the (1)H NMR timescale. These characteristics determined the appearance of a new asymmetry element (supramolecular conformational chirality) in the assemblies that accounted for some of the magnetic asymmetries featured by the capsule's inner space. The racemization of the supramolecular chirality element was fast on the EXSY timescale and produced the chemical exchange processes detected for the encapsulation complexes.
Thirty-five year review of a mercury monitoring service for Scottish dental practices.
Duncan, A; O'Reilly, D Stj; McDonald, E B; Watkins, T R; Taylor, M
2011-02-12
To review a long-standing mercury monitoring service offered to staff in dental practices in Scotland. During the first 20 years of the service, dentists and their staff were contacted by letter and invited to participate. Respondents were asked to collect samples of head hair, pubic hair, fingernail and toenail for analysis of mercury. After 1995, head hair samples were collected initially and further samples were only measured if head hair mercury was elevated. At the start of this scheme many staff, including administrative staff, had systemic exposure to mercury (defined as increased mercury in all four samples). Incidents of exposure have decreased over the 35 years and are now very rare. Male staff were found to have higher mercury concentrations than female staff and dentists tended to have higher concentrations than other staff. Staff working in dental practices more than five years old had small but discernable increases in head hair mercury concentration. In recent years the use of reusable capsules such as Dentomats has been associated with a slight but statistically significant increase in head hair mercury concentrations when compared to the use of encapsulated amalgam systems. Staff wearing open-toed footwear had significantly higher toenail mercury concentrations compared to those who wore shoes. Exposure of staff to mercury in Scottish dental practices is currently now very low. This is probably as a result of increased awareness to the toxicity of mercury and improved methods of preparing amalgam. It may be possible to reduce exposure further, although probably only slightly, by upgrading practices and using encapsulated mercury amalgam.
Merrill, L.C.
1958-06-17
An electromagetic recording head is described for simultaneous recording of a plurality of signals within a small space on a magnetically semsitized medium. Basically the head structure comprises a non-magnetic centerpiece provided with only first and second groups of spaced cut-out slots respectively on opposite sides of the centerpiece. The two groups of slots are in parallel alignment and the slots of one group are staggered with respect to the slots of the other group so that one slot is not directly opposite another slot. Each slot has a magnet pole piece disposed therein and cooperating with a second pole and coil to provide a magnetic flux gap at the upper end of the slot. As a tape is drawn over the upper end of the centerpiece the individual magnetic circuits are disposed along its width to provide means for simultaneously recording information on separate portions, tracks. of the tape.
Vocal training in an anthropometrical aspect.
Wyganowska-Świątkowska, Marzena; Kowalkowska, Iwona; Flicińska-Pamfil, Grażyna; Dąbrowski, Mikołaj; Kopczyński, Przemysław; Wiskirska-Woźnica, Bożena
2017-12-01
As shown in our previous paper, the dimensions of the cerebral parts of the cranium and face of the vocal students were higher than those of the non-singing students. The aim of the present study was to analyse the type of voice and its development depending on selected dimensions. A total of 56 vocal students - 36 women and 20 men - who underwent anthropometric measurements were divided into groups according to their voice type. Two professors of singing made a subjective, independent evaluation of individual students' vocal development progress during the four years of training. The findings were analysed statistically with the current licensed versions of Statistica software. We found statistically significant positive correlation between: the head length, head and face width, depth of upper and middle face, nose length and student's voice development. The dimensions of the head and the face have no impact on type of voice; however, some anatomical characteristics may have impact on voice development.
Margerison, J K; Robarts, A D J; Reynolds, G W
2013-10-01
Increasing early (<3 mo) nutrient feeding levels and growth rate of dairy calves has been found to increase their milk production potential. The objective of this study was to compare the effect of offering milk diets with or without added carbohydrates and amino acids on calf growth, weaning age, and subsequent growth and milk yield of dairy heifers in their first lactation. Friesian calves born at Massey University (n=57) were selected at random, weighed, and allocated to receive 1 of 3 diets. All calves were fed colostrum from 1 to 3d of age, followed by 4 L of whole milk (WM) per head per day and probiotics between 3 and 18d of age. At 18d of age, calves were weighed to ensure mean body weight (BW); then, at 19 d of age, calves changed diets to 1 of 3 treatments, which reached full treatment rate at 21 d of age. The diets were 4 L/head per day of WM (M); 4 L/head per day of WM plus 200 g of plant carbohydrates (MP); and 4 L/head per day of WM plus 200 g of plant carbohydrates with amino acids (MPA). Calves were weaned upon reaching a BW of 90 kg. During this period, BW, body condition, and hip height and width were measured. The heifers were commingled and grazed on ryegrass and white clover pastures until calving at 23 mo of age, when BW, body condition, and hip height and width were measured again. Milk yield and composition were measured throughout first lactation. At weaning, calves fed MPA had greater mean BW gain, a lower number of days to target BW, and a greater mean hip width gain compared with calves in the M group, although mean gain in hip height did not differ among treatments. Total calf starter intake during the milk period was lower for MPA-fed calves compared with those offered M, mainly due to a shorter milk feeding period required to attain the 90-kg weaning weight, whereas mean daily starter intake and straw intake did not differ. No difference was observed in the calving rate or calving age of heifers in any of the dietary feeding groups. First lactation fat-corrected milk yield, milk fat percentage, and total milk fat and protein yields were greater for animals reared on MP and MPA compared with M. Body weight, hip height and width at parturition, milk protein percentage, somatic cell count, or days in milk did not differ among treatments. Increasing nutrient intake, during the milk feeding period, improved the BW gain of calves and milk production of dairy heifers during first lactation. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Facial type and head posture of nasal and mouth-breathing children.
Bolzan, Geovana de Paula; Souza, Juliana Alves; Boton, Luane de Moraes; Silva, Ana Maria Toniolo da; Corrêa, Eliane Castilhos Rodrigues
2011-12-01
To verify the facial type and the head posture of nasal and mouth-breathing children from habitual and obstructive etiologies, as well as to correlate the morphological facial index to the head angulation position in the sagittal plane. Participants were 59 children with ages between 8 years and 11 years and 10 months. All subjects were undergone to speech-language pathology screening, otorhinolaryngologic evaluation, and nasopharyngoscopy, allowing the constitution of three groups: nasal breathers--15 children; mouth breathers from obstructive etiology--22 children; and habitual mouth breathers--22 children. In order to determine facial type and morphological facial index, the height and the width of the face were measured using a digital caliper. The head posture was assessed through physical examination and computerized photogrammetry. It was verified the predominance of short face in nasal breathers, and long face in mouth breathers. There was an association among facial type and breathing mode/mouth breathing etiology: the brachyfacial type was more frequent among nasal breathers, and less frequent in subjects with obstructive nasal breathing. Head posture was similar in all three groups. No correlation was found between morphological facial index and head posture. The brachyfacial type favors the nasal-breathing mode and the head posture is not influenced by breathing mode and by the etiology of mouth breathing, as well as it is not related to facial type.
A Comparison of Removal Rates of Headless Screws Versus Headed Screws in Calcaneal Osteotomy.
Kunzler, Daniel; Shazadeh Safavi, Pejma; Jupiter, Daniel; Panchbhavi, Vinod K
2017-11-01
Calcaneal osteotomy has been used to successfully treat both valgus and varus hindfoot deformities. Pain associated with implanted hardware may lead to further surgical intervention for hardware removal. Headless screws have been used to reduce postoperative hardware-associated pain and accompanying hardware removal, but data proving their effectiveness in this regard is lacking. The purpose of this study is to compare the rates of removal of headed and headless screws utilized in calcaneal osteotomy. We conducted a retrospective chart review of 74 patients who underwent calcaneal osteotomy between January 2010 and December 2014. The cohort was divided into 2 groups by fixation method: a headed screw and a headless screw group. Bivariate associations between infection or hardware removal, and screw type, screw head width, gender, smoking status, alcohol, hypertension, diabetes, hyperlipidemia, age, and body mass index were assessed using t-tests and Fisher's exact/χ 2 tests for continuous and discrete variables, respectively. Headed screws were removed more frequently than headless screws (P < .0001): 15 of 30 (50%) feet that received headed screws and 4 of 44 (9%) of feet that received headless screws underwent subsequent revision for screw removal. In all cases, screws were removed because of pain. The calcaneal union rate was 100% in both cohorts. The rate of screw removal in calcaneal osteotomies is significantly lower in patients who receive headless screws than in those receiving headed screws. Level IV.
NASA Technical Reports Server (NTRS)
Martin, J. P.; Kok, B.; Radmer, R.
1976-01-01
A system has been under development which is designed to seek remotely for clues to life in planetary soil samples. The basic approach is a set of experiments, all having a common sensor, a gas analysis mass spectrometer which monitors gas composition in the head spaces above sealed, temperature controlled soil samples. Versatility is obtained with up to three preloaded, sealed fluid injector capsules for each of eleven soil test cells. Tests results with an engineering model has demonstrated performance capability of subsystem components such as soil distribution, gas sampling valves, injector mechanisms, temperature control, and test cell seal.
The Primer for Sports Medicine Professionals on Imaging
Farshad-Amacker, Nadja A.; Jain Palrecha, Sapna; Farshad, Mazda
2013-01-01
Because of its inherent superior soft tissue contrast and lack of ionizing radiation, magnetic resonance imaging (MRI) is highly suited to study the complex anatomy of the shoulder joint, particularly when assessing the relatively high incidence of shoulder injuries in young, athletic patients. This review aims to serve as a primer for understanding shoulder MRI in an algorithmical approach, including MRI protocol and technique, normal anatomy and anatomical variations of the shoulder, pathologic conditions of the rotator cuff tendons and muscles, the long head of the biceps tendon, shoulder impingement, labral and glenohumeral ligament pathology, MR findings in shoulder instability, adhesive capsulitis, and osteoarthritis. PMID:24381700
DOE Office of Scientific and Technical Information (OSTI.GOV)
Endo, Yasushi, E-mail: endo@ecei.tohoku.ac.jp; Fan, Peng; Yamaguchi, Masahiro
To understand the spin-torque effect on the noise in tunneling magnetoresistive (TMR) read heads, the GHz range noise spectra of TMR read heads with a narrow track width (w = 36 nm), and various stripe heights (h) are investigated as a function of the external magnetic field (H{sub ex}) and dc bias current density (j). The strong noise peak intensity depends on both H{sub ex} and j, indicating that the spin-torque affects the thermal mag-noise under a positive (negative) j for a positive (negative) H{sub ex}, regardless of h in the TMR heads. Due to the increased shape anisotropy, the critical current densitymore » (j{sub c}), where the non-thermal fluctuation noise originates from the spin-torque, increases markedly as the head dimension is reduced, and the maximum value of j{sub c} is approximately +1.5 × 10{sup 12} A/m{sup 2} for a head with w = 36 nm and h = 15 nm. These results demonstrate that the non-thermal fluctuation noise originating from the spin-torque in the TMR head can be suppressed in the current density range below 10{sup 12} A/m{sup 2}, as the head dimension is reduced and the shape anisotropy is increased.« less
Demura, S; Sato, S; Kitabayashi, T
2006-06-01
This study examined a method of predicting body density based on hydrostatic weighing without head submersion (HWwithoutHS). Donnelly and Sintek (1984) developed a method to predict body density based on hydrostatic weight without head submersion. This method predicts the difference (D) between HWwithoutHS and hydrostatic weight with head submersion (HWwithHS) from anthropometric variables (head length and head width), and then calculates body density using D as a correction factor. We developed several prediction equations to estimate D based on head anthropometry and differences between the sexes, and compared their prediction accuracy with Donnelly and Sintek's equation. Thirty-two males and 32 females aged 17-26 years participated in the study. Multiple linear regression analysis was performed to obtain the prediction equations, and the systematic errors of their predictions were assessed by Bland-Altman plots. The best prediction equations obtained were: Males: D(g) = -164.12X1 - 125.81X2 - 111.03X3 + 100.66X4 + 6488.63, where X1 = head length (cm), X2 = head circumference (cm), X3 = head breadth (cm), X4 = head thickness (cm) (R = 0.858, R2 = 0.737, adjusted R2 = 0.687, standard error of the estimate = 224.1); Females: D(g) = -156.03X1 - 14.03X2 - 38.45X3 - 8.87X4 + 7852.45, where X1 = head circumference (cm), X2 = body mass (g), X3 = head length (cm), X4 = height (cm) (R = 0.913, R2 = 0.833, adjusted R2 = 0.808, standard error of the estimate = 137.7). The effective predictors in these prediction equations differed from those of Donnelly and Sintek's equation, and head circumference and head length were included in both equations. The prediction accuracy was improved by statistically selecting effective predictors. Since we did not assess cross-validity, the equations cannot be used to generalize to other populations, and further investigation is required.
Belke, Marcus; Heverhagen, Johannes T; Keil, Boris; Rosenow, Felix; Oertel, Wolfgang H; Stiasny-Kolster, Karin; Knake, Susanne; Menzler, Katja
2015-01-01
Background and Purpose We evaluated cerebral white and gray matter changes in patients with iRLS in order to shed light on the pathophysiology of this disease. Methods Twelve patients with iRLS were compared to 12 age- and sex-matched controls using whole-head diffusion tensor imaging (DTI) and voxel-based morphometry (VBM) techniques. Evaluation of the DTI scans included the voxelwise analysis of the fractional anisotropy (FA), radial diffusivity (RD), and axial diffusivity (AD). Results Diffusion tensor imaging revealed areas of altered FA in subcortical white matter bilaterally, mainly in temporal regions as well as in the right internal capsule, the pons, and the right cerebellum. These changes overlapped with changes in RD. Voxel-based morphometry did not reveal any gray matter alterations. Conclusions We showed altered diffusion properties in several white matter regions in patients with iRLS. White matter changes could mainly be attributed to changes in RD, a parameter thought to reflect altered myelination. Areas with altered white matter microstructure included areas in the internal capsule which include the corticospinal tract to the lower limbs, thereby supporting studies that suggest changes in sensorimotor pathways associated with RLS. PMID:26442748
Notarnicola, Juliana; Jiménez, F Agustín; Gardner, Scott L
2012-12-01
We report the distribution of 2 species of filarioid nematodes occurring in different hosts in the central region of South America. Molinema boliviensis n. sp. was recorded as a parasite of sigmodontine and echymyid rodents in Bolivia, and Litomosoides esslingeri was recorded in sigmodontine and ctenomyid rodents from Bolivia and Argentina. Molinema boliviensis n. sp. shares several similarities with other species reported in spiny rats; however, it can be easily differentiated by the presence of a flat anterior end, gradually tapering lappets and a tubercle present in posterior end, a short, uniform buccal capsule, an oval-shaped vagina vera, and a ratio of spicules of 1:1.44. An account for the morphological variability of L. esslingeri is presented that allows the identification of the buccal capsule, the tail tip in females, and the shape of spicules as reliable diagnostic traits. A complete set of head papillae is also described. The finding of these parasites in phylogenetically unrelated hosts suggests that host capture may be a frequent phenomenon in these filarioids. Researchers should focus efforts in surveying mammals within the same ecological guild to understand the distribution and host specificity of these nematodes.
[A cadaveric study of a new capsulorrhaphy for the surgical treatment of hallux valgus].
Orozco-Villaseñor, S L; Monzó-Planella, M; Martín-Oliva, X; Vázquez-Escamilla, J; Mayagoitia-Vázquez, J J; Frías-Chimal, J E
2017-01-01
There are many surgical options for the treatment of hallux valgus in combination with capsular repairs for the correction of hallux valgus. This report corresponds to a descriptive study where a new capsulorrhaphy technique in hallux valgus is proposed. Six dissections were performed on cadavers with hallux valgus deformity using the following surgical technique: medial approach on the first toe longitudinally, dissecting by planes and locating the metatarsophalangeal joint capsule; it was incised longitudinally. The capsule was separated and an exostectomy of the first metatarsal head was done, the edges were regularized and a release of the abductor hallucis was performed. Later, the capsular remnant was resected and repaired. Six cadaveric feet with hallux valgus were studied, five with mild deformity, one with moderate deformity, one foot with the 2nd finger on supraductus. Many capsular repairs have been reported in the literature, including «L», triangular, «V-Y», rectangular, with satisfactory results, along with osteotomy of the first metatarsal. In this report, a new capsular repair was described. Applying this new capsular repair, we reduced the metatarsophalangeal and intermetatarsal angles and achieved a capsular closure with suitable tension; the metatarsophalangeal joint mobility was preserved.
Joint Services Electronics Program.
1983-09-30
environment. The research is under three interrelated heads: (1) algebraic Methodologies for Control Systems design , both linear and non -linear, (2) robust...properties of the device. After study of these experimental results, we plan to design a millimeter- wave version of the Gunn device. This will...appropriate dose discretization level for an adju- stable width beam. 2) Experimental Device Fabrication In a collaborative effort with the IC design group
33 CFR 110.195 - Mississippi River below Baton Rouge, LA, including South and Southwest Passes.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (ALWP). (1) Pilottown Anchorage. An area 5.2 miles in length along the right descending bank of the river from mile 1.5 to mile 6.7 above Head of Passes, extending in width to 1600 feet from the left... are urged to use caution in this anchorage. (2) Lower Venice Anchorage. An area 1.6 miles in length...
33 CFR 110.195 - Mississippi River below Baton Rouge, LA, including South and Southwest Passes.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (ALWP). (1) Pilottown Anchorage. An area 5.2 miles in length along the right descending bank of the river from mile 1.5 to mile 6.7 above Head of Passes, extending in width to 1600 feet from the left... are urged to use caution in this anchorage. (2) Lower Venice Anchorage. An area 1.6 miles in length...
33 CFR 110.195 - Mississippi River below Baton Rouge, LA, including South and Southwest Passes.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (ALWP). (1) Pilottown Anchorage. An area 5.2 miles in length along the right descending bank of the river from mile 1.5 to mile 6.7 above Head of Passes, extending in width to 1600 feet from the left... are urged to use caution in this anchorage. (2) Lower Venice Anchorage. An area 1.6 miles in length...
Tarroun, Abdullah; Bonnefoy, Marc; Bouffard-Vercelli, Juliette; Gedeon, Claire; Vallee, Bernard; Cotton, François
2007-02-01
Although mild progressive specific structural brain changes are commonly associated with normal human aging, it is unclear whether automatic or manual measurements of these structures can differentiate normal brain aging in elderly persons from patients suffering from cognitive impairment. The objective of this study was primarily to define, with a standard high resolution MRI, the range of normal linear age-specific values for the hippocampal formation (HF), and secondarily to differentiate hippocampal atrophy in normal aging from that occurring in Alzheimer disease (AD). Two MRI-based linear measurements of the hippocampal formation at the level of the head and of the tail, standardized by the cranial dimensions, were obtained from coronal and sagittal T1-weighted MR images in 25 normal elderly subjects, and 26 patients with AD. In this study, dimensions of the HF have been standardized and they revealed normal distributions for each side and each sex: the width of the hippocampal head at the level of the amygdala was 16.42 +/- 1.9 mm, and its height 7.93 +/- 1.4 mm; the width of the tail at the level of the cerebral aqueduct was 8.54 +/- 1.2 mm, and the height 5.74 +/- 0.4 mm. There were no significant differences in standardized dimensions of the HF between sides, sexes, or in comparison to head dimensions in the two groups. In addition, the median inter-observer agreement index was 93%. In contrast, the dimensions of the hippocampal formation decreased gradually with increasing age, owing to physiological atrophy, but this atrophy is more significant in the group of AD.
Al-Tabakha, Moawia M; Arida, Adi Issam; Fahelelbom, Khairi M S; Sadek, Bassem; Saeed, Dima Ahmed; Abu Jarad, Rami A; Jawadi, Jeevani
2015-01-01
The purpose of this study was to assess the in vitro performances of "vegetable" capsules in comparison to hard gelatin capsules in terms of shell weight variation, reaction to different humidity conditions, resistance to stress in the absence of moisture, powder leakage, disintegration and dissolution. Two types of capsules made of HPMC produced with (Capsule 2) or without (Capsule 3) a gelling agent and hard gelatin capsules (Capsule 1) were assessed. Shell weight variability was relatively low for all tested capsules shells. Although Capsule 1 had the highest moisture content under different humidity conditions, all capsule types were unable to protect the encapsulated hygroscopic polyvinylpyrrolidone (PVP) powder from surrounding humidity. The initial disintegration for all Capsule 1 occurred within 3 min, but for other types of capsules within 6 min (n = 18). Dissolution of acetaminophen was better when the deionized water (DIW) temperature increased from 32 to 42 °C in case of Capsule 1, but the effect of temperature was not significant for the other types of capsules. Acetaminphen dissolution from Capsule 1 was the fastest (i.e. >90% in 10 min) and independent of the media pH or contents unlike Capsule 2 which was influenced by the pH and dissolution medium contents. It is feasible to use hypromellose capsules shells with or without gelling agent for new lines of pharmaceutical products, however, there is a window for capsule shells manufacturing companies to improve the dissolution of their hypromellose capsules to match the conventional gelatin capsule shells and eventually replace them.
Male Weaponry in a Fighting Cricket
Judge, Kevin A.; Bonanno, Vanessa L.
2008-01-01
Sexually selected male weaponry is widespread in nature. Despite being model systems for the study of male aggression in Western science and for cricket fights in Chinese culture, field crickets (Orthoptera, Gryllidae, Gryllinae) are not known to possess sexually dimorphic weaponry. In a wild population of the fall field cricket, Gryllus pennsylvanicus, we report sexual dimorphism in head size as well as the size of mouthparts, both of which are used when aggressive contests between males escalate to physical combat. Male G. pennsylvanicus have larger heads, maxillae and mandibles than females when controlling for pronotum length. We conducted two experiments to test the hypothesis that relatively larger weaponry conveys an advantage to males in aggressive contests. Pairs of males were selected for differences in head size and consequently were different in the size of maxillae and mandibles. In the first experiment, males were closely matched for body size (pronotum length), and in the second, they were matched for body mass. Males with proportionately larger weaponry won more fights and increasing differences in weaponry size between males increased the fighting success of the male with the larger weaponry. This was particularly true when contests escalated to grappling, the most intense level of aggression. However, neither contest duration nor intensity was related to weaponry size as predicted by models of contest settlement. These results are the first evidence that the size of the head capsule and mouthparts are under positive selection via male-male competition in field crickets, and validate 800-year-old Chinese traditional knowledge. PMID:19107188
δ-Catenin Regulates Spine Architecture via Cadherin and PDZ-dependent Interactions*
Yuan, Li; Seong, Eunju; Beuscher, James L.; Arikkath, Jyothi
2015-01-01
The ability of neurons to maintain spine architecture and modulate it in response to synaptic activity is a crucial component of the cellular machinery that underlies information storage in pyramidal neurons of the hippocampus. Here we show a critical role for δ-catenin, a component of the cadherin-catenin cell adhesion complex, in regulating spine head width and length in pyramidal neurons of the hippocampus. The loss of Ctnnd2, the gene encoding δ-catenin, has been associated with the intellectual disability observed in the cri du chat syndrome, suggesting that the functional roles of δ-catenin are vital for neuronal integrity and higher order functions. We demonstrate that loss of δ-catenin in a mouse model or knockdown of δ-catenin in pyramidal neurons compromises spine head width and length, without altering spine dynamics. This is accompanied by a reduction in the levels of synaptic N-cadherin. The ability of δ-catenin to modulate spine architecture is critically dependent on its ability to interact with cadherin and PDZ domain-containing proteins. We propose that loss of δ-catenin during development perturbs synaptic architecture leading to developmental aberrations in neural circuit formation that contribute to the learning disabilities in a mouse model and humans with cri du chat syndrome. PMID:25724647
Biocompatible Capsules and Methods of Making
NASA Technical Reports Server (NTRS)
Loftus, David J. (Inventor)
2017-01-01
Embodiments of the invention include capsules for containing medical implants and delivery systems for release of active biological substances into a host body. Delivery systems comprise a capsule comprising an interior enclosed by walls, and a source of active biological substances enclosed within the capsule interior, wherein the active biological substances are free to diffuse across the capsule walls. The capsule walls comprise a continuous mesh of biocompatible fibers and a seal region where two capsule walls overlap. The interior of the capsule is substantially isolated from the medium surrounding the capsule, except for diffusion of at least one species of molecule between the capsule interior and the ambient medium, and prevents cell migration into or out of the capsule. Methods for preparing and using the capsules and delivery systems are provided.
Chatterjee, S; Mott, J H; Smyth, G; Dickson, S; Dobrowsky, W; Kelly, C G
2011-04-01
Intensity-modulated radiotherapy (IMRT) is increasingly being used to treat head and neck cancer cases. We discuss the clinical challenges associated with the setting up of an image guided intensity modulated radiotherapy service for a subset of head and neck cancer patients, using a recently commissioned helical tomotherapy (HT) Hi Art (Tomotherapy Inc, WI) machine in this article. We also discuss the clinical aspects of the tomotherapy planning process, treatment and image guidance experiences for the first 10 head and neck cancer cases. The concepts of geographical miss along with tomotherapy-specific effects, including that of field width and megavoltage CT (MVCT) imaging strategy, have been highlighted using the first 10 head and neck cases treated. There is a need for effective streamlining of all aspects of the service to ensure compliance with cancer waiting time targets. We discuss how patient toxicity audits are crucial to guide refinement of the newly set-up planning dose constraints. This article highlights the important clinical issues one must consider when setting up a head and neck IMRT, image-guided radiotherapy service. It shares some of the clinical challenges we have faced during the setting up of a tomotherapy service. Implementation of a clinical tomotherapy service requires a multidisciplinary team approach and relies heavily on good team working and effective communication between different staff groups.
Wu, Kai; Huang, Jianhua; Wang, Qiugen
2016-01-01
We aimed to analyze the intracapsular pressure of the hip joint following femoral neck fracture and its relationship to the position of the hip or to traction and (using superselective arteriography) to evaluate the blood supply to the femoral head and the influence of traction and hip position on the blood supply. Twenty-six cases of fresh Garden type I-III femoral neck fractures were enrolled. After being placed in the neutral position, in internal rotation or with traction of 3 and 5 kg, respectively, intracapsular manometric changes were measured. Eight cases underwent superselective arteriography of the medial circumflex femoral artery and its branches under the manometric changes of the hip joint capsule. Twenty-four to 48 h after the injury, the intracapsular pressure was significantly higher on the fractured side than on the normal side. The mean pressure was 28.41 ± 9.339 mm Hg in fully extended hips in the neutral position, 79.92 ± 12.80 mm Hg in internally rotated hips, 51.39 ± 15.41 mm Hg in hips with 3 kg of traction and 64.81 ± 13.56 mm Hg in hips with 5 kg of traction. The arteriographic findings revealed that traction and internal rotation reduced the perfusion of the femoral head at the medial circumflex femoral artery and its branches, and also negatively influenced venous reflux. Traction and internal rotation both caused the intracapsular pressure of the hip joint to rise considerably, which reduced the femoral head perfusion and impeded venous reflux. This could lead to avascular necrosis of the femoral head. © 2015 S. Karger AG, Basel.
Origin of the direct and reflected head of the rectus femoris: an anatomic study.
Ryan, John M; Harris, Joshua D; Graham, William C; Virk, Sohrab S; Ellis, Thomas J
2014-07-01
This study aimed to define the footprint of the direct and reflected heads of the rectus femoris and the relation of the anterior inferior iliac spine (AIIS) to adjacent neurovascular (lateral circumflex femoral artery and femoral nerve), bony (anterior superior iliac spine [ASIS]), and tendinous structures (iliopsoas). Twelve fresh-frozen cadaveric hip joints from 6 cadavers, average age of 44.5 (±9.9) years, were carefully dissected of skin and fascia to expose the muscular, capsular, and bony structures of the anterior hip and pelvis. Using digital calipers, measurements were taken of the footprint of the rectus femoris on the AIIS, superior-lateral acetabulum and hip capsule, and adjacent anatomic structures. The average dimensions of the footprint of the direct head of the rectus femoris were 13.4 mm (±1.7) × 26.0 mm (±4.1), whereas the dimensions of the reflected head footprint were 47.7 mm (±4.4) × 16.8 mm (±2.2). Important anatomic structures, including the femoral nerve, psoas tendon, and lateral circumflex femoral artery, were noted in proximity to the AIIS. The neurovascular structure closest to the AIIS was the femoral nerve (20.8 ± 3.4 mm). The rectus femoris direct and reflected heads originate over a broad area of the anterolateral pelvis and are in close proximity to critical neurovascular structures, and care must be taken to avoid them during hip arthroscopy. A thorough knowledge of the anatomy of the proximal rectus femoris is valuable for any surgical exposure of the anterior hip joint, particularly arthroscopic subspine decompression and open femoroacetabular impingement (FAI) surgery. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Causse, Julien; Wang, Xuguang; Denninger, Lisa
2012-01-01
This study aimed at experimentally investigating the influence of roof height and sill width on car ingress/egress movements. The first uncomfortable (Ht1) and the lowest acceptable (Ht2) roof heights were obtained from 26 participants of three different stature groups thanks to a multi-adjustable vehicle mock-up. Both Ht1 and Ht2 were affected neither by stature nor by vehicle type. Only a difference of 45 mm between Ht1 and Ht2 was observed. Tall volunteers more flexed the trunk and neck than short persons thanks to a larger space available around the seat when the head passing under the roof. The vehicle type had almost no effect on upper body posture. The roof height only affected neck flexion. The sill width mainly imposed a lateral translation. Results demonstrated that an appropriate roof height should be determined carefully. A small change of 45 mm in roof height may lead to an unacceptable situation. The present study experimentally investigated the effects of roof height and sill width on car ingress and egress movements. Short females required almost the same roof height as tall males due to smaller space around the seat. The results would help to optimise car dimensions for improving car accessibility.
METTLER, R. D.; SPELLMAN, G. M.
2014-01-01
Black-headed Grosbeaks (Pheucticus melanocephalus) and Rose-breasted Grosbeaks (Pheucticus ludovicianus) are passerine bird species known to hybridize in the Great Plains of North America. Both extrinsic (environmental) and intrinsic factors (pre- and postzygotic reproductive isolation) have been credited for the generation and maintenance of the grosbeak hybrid zone, but little is known about the genetic characteristics of this hybrid zone. To investigate the stability and extent of the grosbeak hybrid zone, we constructed clines from both molecular sequence data (mtDNA, 3 autosomal intron loci, and 1 Z-linked locus) and morphological data (morphometric analyses and hybrid index scores) to determined zone center and width. Hybrid zone center and width were also determined for samples collected across the zone 40 years ago from morphological data. The present and past clines were compared and provided support for stability in hybrid zone location and width, and the evolutionary implications of this are discussed. Three models of hybrid zone maintenance were investigated to consider the influence of intrinsic and extrinsic factors on this zone. Our results suggest low hybrid frequencies, a stable zone location and narrow width, and reduced hybrid fitness over the past 40 years best categorize the grosbeak hybrid zone as a tension zone. PMID:19619198
48-hour wireless oesophageal pH-monitoring in children: are two days better than one?
Gunnarsdóttir, A; Stenström, P; Arnbjörnsson, E
2007-12-01
Use of a catheter-free, radio telemetric, oesophageal pH-monitoring system in paediatric clinical practice allows patients to follow a more normal physiological pattern of activities and causes less discomfort. At our institution, placement of the capsule is done under general anaesthesia, which restricts the child's activity during the first day. The aim of this study was to determine whether oesophageal pH-measurements should be performed over 48 hours or whether 24-hour measurement provides sufficient and reliable results. The study included 24 consecutive children with symptomatic gastro-oesophageal reflux problems who had undergone upper gastrointestinal endoscopies under general anaesthesia. The radio-transmitting Bravo capsule was introduced transorally and placed above the diaphragm at a width of two vertebral bodies. Oesophageal acid exposure was monitored via a portable receiver for 48 hours. The children's symptoms during measurements were registered. Wilcoxon signed rank test for paired samples was used after power analysis. The capsule was successfully attached to the oesophageal mucosa in all cases with minor technical problems in only one patient. The 48-hour pH-monitoring was completed in 23 patients. The median percentage time with an oesophageal pH of less than 4 was 5.4 +/- 6.8 for the first 24 hours and 5.8 +/- 7.4 for the 48-hour measurement. The DeMeester score was 20.5 +/- 23.7 and 22.2 +/- 25.7, respectively. Ambulatory pH-monitoring using the wireless system is feasible and safe. It was well-tolerated by the children. There was no statistical difference between the pH-measurements or DeMeester scores during the first 24 hours compared with the 48-hour measurements. Individual variations were noted but had no clinical significance except in two patients. Our results support the use of pH-measurement for a period of 24 hours only.
Stylostome formation in trombiculid mites (Acariformes: Trombiculidae).
Shatrov, Andrew B
2009-12-01
Stylostomes of the trombiculid mite larvae Neotrombicula pomeranzevi (Schluger), Hirsutiella zachvatkini (Schluger), Miyatrombicula esoensis (Sasa and Ogata) and Euschoengastia rotundata (Schluger) (Acariformes: Trombiculidae), formed in the host skin during feeding of the parasites on their natural hosts (voles) were studied histologically and histochemically. A stylostome is a variously shaped tube formed of solidified mite saliva that extends from the mouthparts of the parasite through the epidermis into the dermis of the host, and allows the mite to obtain its liquid food. The first step of stylostome formation is deposition of an eosinophilic cone, to which the larva's chelicerae are glued. Organization of the stylostome depends on the mite species, and its walls may show weakly expressed longitudinal or transverse stratification. Histochemically, the stylostome is composed of complex glycoprotein with varying tinctorial properties through the width or the length of the stylostome's walls. Beneath the distal end of the stylostome, irrespectively of its localization either in the epidermis or in the dermis of the host, a feeding cavity is formed as a result of the action of the hydrolytic components of the mite's saliva forced through the stylostome into the wound. An inflammatory dermal reaction of moderate intensity is evolved during larval feeding and stylostome formation. It is manifested by the infiltration of the foci with neutrophiles, lymphocytes and macrophages and by dilation of capillaries of the terminal vessel bed and filling them by erythrocytes and other blood elements. Around the stylostome, necrosis of the epidermal cells occurs, leucocytes come to the damaged area and fuse with the necrotic epidermal cells, leading to the formation of the large scabs on the surface of the host's skin. In the case of E. rotundata, single capsules having a terminal opening and containing feeding larva are formed on the abdomen of the hosts. The walls of the capsules are composed of the mite's saliva flowing upon the surface of the host's skin. At the bottom of the capsule, a stylostome perforating the epidermis is also present.
A blue optical filter for narrow-band imaging in endoscopic capsules
NASA Astrophysics Data System (ADS)
Silva, M. F.; Ghaderi, M.; Goncalves, L. M.; de Graaf, G.; Wolffenbuttel, R. F.; Correia, J. H.
2014-05-01
This paper presents the design, simulation, fabrication, and characterization of a thin-film Fabry-Perot resonator composed of titanium dioxide (TiO2) and silicon dioxide (SiO2) thin-films. The optical filter is developed to be integrated with a light emitting diode (LED) for enabling narrow-band imaging (NBI) in endoscopy. The NBI is a high resolution imaging technique that uses spectrally centered blue light (415 nm) and green light (540 nm) to illuminate the target tissue. The light at 415 nm enhances the imaging of superficial veins due to their hemoglobin absorption, while the light at 540 nm penetrates deeper into the mucosa, thus enhances the sub-epithelial vessels imaging. Typically the endoscopes and endoscopic capsules use white light for acquiring images of the gastrointestinal (GI) tract. However, implementing the NBI technique in endoscopic capsules enhances their capabilities for the clinical applications. A commercially available blue LED with a maximum peak intensity at 404 nm and Full Width Half Maximum (FWHM) of 20 nm is integrated with a narrow band blue filter as the NBI light source. The thin film simulations show a maximum spectral transmittance of 36 %, that is centered at 415 nm with FWHM of 13 nm for combined the blue LED and a Fabry Perot resonator system. A custom made deposition scheme was developed for the fabrication of the blue optical filter by RF sputtering. RF powered reactive sputtering at 200 W with the gas flows of argon and oxygen that are controlled for a 5:1 ratio gives the optimum optical conditions for TiO2 thin films. For SiO2 thin films, a non-reactive RF sputtering at 150 W with argon gas flow at 15 sccm results in the best optical performance. The TiO2 and SiO2 thin films were fully characterized by an ellipsometer in the wavelength range between 250 nm to 1600 nm. Finally, the optical performance of the blue optical filter is measured and presented.
Novel MRI tests of orocecal transit time and whole gut transit time: studies in normal subjects
Chaddock, G; Lam, C; Hoad, C L; Costigan, C; Cox, E F; Placidi, E; Thexton, I; Wright, J; Blackshaw, P E; Perkins, A C; Marciani, L; Gowland, P A; Spiller, R C
2014-01-01
Background Colonic transit tests are used to manage patients with Functional Gastrointestinal Disorders. Some tests used expose patients to ionizing radiation. The aim of this study was to compare novel magnetic resonance imaging (MRI) tests for measuring orocecal transit time (OCTT) and whole gut transit time (WGT), which also provide data on colonic volumes. Methods 21 healthy volunteers participated. Study 1: OCTT was determined from the arrival of the head of a meal into the cecum using MRI and the Lactose Ureide breath test (LUBT), performed concurrently. Study 2: WGT was assessed using novel MRI marker capsules and radio-opaque markers (ROMs), taken on the same morning. Studies were repeated 1 week later. Key Results OCTT measured using MRI and LUBT was 225 min (IQR 180–270) and 225 min (IQR 165–278), respectively, correlation rs = 0.28 (ns). WGT measured using MRI marker capsules and ROMs was 28 h (IQR 4–50) and 31 h ± 3 (SEM), respectively, correlation rs = 0.85 (p < 0.0001). Repeatability assessed using the intraclass correlation coefficient (ICC) was 0.45 (p = 0.017) and 0.35 (p = 0.058) for MRI and LUBT OCTT tests. Better repeatability was observed for the WGT tests, ICC being 0.61 for the MRI marker capsules (p = 0.001) and 0.69 for the ROM method (p < 0.001) respectively. Conclusions & Inferences The MRI WGT method is simple, convenient, does not use X-ray and compares well with the widely used ROM method. Both OCTT measurements showed modest reproducibility and the MRI method showed modest inter-observer agreement. PMID:24165044
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alkhatib, H; Oves, S
Purpose: To demonstrate a quick and comprehensive method verifying the accuracy of the updated dose model by recalculating dose distribution in an anthropomorphic phantom with a new version of the TPS and comparing the results to measured values. Methods: CT images and IMRT plan of an RPC anthropomorphic head phantom, previously calculated by Pinnacle 9.0, was re-computed using Pinnacle 9.2 and 9.6. The dosimeters within the phantom include four TLD capsules representing a primary PTV, two TLD capsules representing a secondary PTV, and two TLD capsules representing an organ at risk. Also included were three sheets of Gafchromic film. Performancemore » of the updated TPS version was assessed by recalculating point doses and dose profiles corresponding to TLD and film position respectively and then comparing the results to reported values by the RPC. Results: Comparing calculated doses to reported measured doses from the RPC yielded an average disagreement of 1.48%, 2.04% and 2.10% for versions 9.0, 9.2, 9.6 respectively. Computed doses points all meet the RPC's passing criteria with the exception of the point representing the superior organ at risk in version 9.6. However, qualitative analysis of the recalculated dose profiles showed improved agreement with those of the RPC, especially in the penumbra region. Conclusion: This work has demonstrated the calculation results of Pinnacle 9.2 and 9.6 vs 9.0 version. Additionally, this study illustrates a method for the user to gain confidence upgrade to a newer version of the treatment planning system.« less
Controversies In The Surgical Management Of Shoulder Instability: Associated Soft Tissue Procedures
Moros Marco, Santos; Ávila Lafuente, José Luis; Ruiz Ibán, Miguel Angel; Diaz Heredia, Jorge
2017-01-01
Background: The glenohumeral joint is a ball-and-socket joint that is inherently unstable and thus, susceptible to dislocation. The traditional and most common anatomic finding is the Bankart lesion (anterior-inferior capsule labral complex avulsion), but there is a wide variety of anatomic alterations that can cause shoulder instability or may be present as a concomitant injury or in combination, including bone loss (glenoid or humeral head), complex capsule-labral tears, rotator cuff tears, Kim´s lesions (injuries to the posterior-inferior labrum) and rotator interval pathology. Methods: A review of articles related to shoulder anatomy and soft tissue procedures that are performed during shoulder instability arthroscopic management was conducted by querying the Pubmed database and conclusions and controversies regarding this injury were exposed. Results: Due to the complex anatomy of the shoulder and the large range of movement of this joint, a wide variety of anatomic injuries and conditions can lead to shoulder instability, specially present in young population. Recognizing and treating all of them including Bankart repair, capsule-labral plicatures, SLAP repair, circumferential approach to pan-labral lesions, rotator interval closure, rotator cuff injuries and HAGL lesion repair is crucial to achieve the goal of a stable, full range of movement and not painful joint. Conclusion: Physicians must be familiarized with all the lesions involved in shoulder instability, and should be able to recognize and subsequently treat them to achieve the goal of a stable non-painful shoulder. Unrecognized or not treated lesions may result in recurrence of instability episodes and pain while overuse of some of the techniques previously described can lead to stiffness, thus the importance of an accurate diagnosis and treatment when facing a shoulder instability. PMID:28979603
Controversies In The Surgical Management Of Shoulder Instability: Associated Soft Tissue Procedures.
Marco, Santos Moros; Lafuente, José Luis Ávila; Ibán, Miguel Angel Ruiz; Heredia, Jorge Diaz
2017-01-01
The glenohumeral joint is a ball-and-socket joint that is inherently unstable and thus, susceptible to dislocation. The traditional and most common anatomic finding is the Bankart lesion (anterior-inferior capsule labral complex avulsion), but there is a wide variety of anatomic alterations that can cause shoulder instability or may be present as a concomitant injury or in combination, including bone loss (glenoid or humeral head), complex capsule-labral tears, rotator cuff tears, Kim´s lesions (injuries to the posterior-inferior labrum) and rotator interval pathology. A review of articles related to shoulder anatomy and soft tissue procedures that are performed during shoulder instability arthroscopic management was conducted by querying the Pubmed database and conclusions and controversies regarding this injury were exposed. Due to the complex anatomy of the shoulder and the large range of movement of this joint, a wide variety of anatomic injuries and conditions can lead to shoulder instability, specially present in young population. Recognizing and treating all of them including Bankart repair, capsule-labral plicatures, SLAP repair, circumferential approach to pan-labral lesions, rotator interval closure, rotator cuff injuries and HAGL lesion repair is crucial to achieve the goal of a stable, full range of movement and not painful joint. Physicians must be familiarized with all the lesions involved in shoulder instability, and should be able to recognize and subsequently treat them to achieve the goal of a stable non-painful shoulder. Unrecognized or not treated lesions may result in recurrence of instability episodes and pain while overuse of some of the techniques previously described can lead to stiffness, thus the importance of an accurate diagnosis and treatment when facing a shoulder instability.
Double-balloon endoscopy as the primary method for small-bowel video capsule endoscope retrieval.
Van Weyenberg, Stijn J B; Van Turenhout, Sietze T; Bouma, Gerd; Van Waesberghe, Jan Hein T M; Van der Peet, Donald L; Mulder, Chris J J; Jacobs, Maarten A J M
2010-03-01
Capsule retention in the small bowel is a known complication of small-bowel video capsule endoscopy. Surgery is the most frequently used method of capsule retrieval. To determine the incidence and causes of capsule retention and to describe double-balloon endoscopy (DBE) as the primary technique used for capsule retrieval. Retrospective analysis of all video capsule studies was performed at our center, and evaluation of the outcome of DBE was the first method used to retrieve entrapped video capsules. Tertiary referral center. A total of 904 patients who underwent small-bowel video capsule endoscopy. Capsule retrieval by DBE. The number of patients in whom capsule retention occurred and the number of patients in whom an entrapped capsule could be retrieved by using DBE. Capsule retention occurred in 8 patients (incidence 0.88%; 95% CI, 0.41%-1.80%) and caused acute small-bowel obstruction in 6 patients. All retained capsules were successfully removed during DBE. Five patients underwent elective surgery to treat the underlying cause of capsule retention. One patient required emergency surgery because of multiple small-bowel perforations. Retrospective design. In our series, the incidence of capsule retention was low. DBE is a reliable method for removing retained capsules and might prevent unnecessary surgery. If surgery is required, preoperative capsule retrieval allows preoperative diagnosis, adequate staging in case of malignancy, and optimal surgical planning. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Design and synthesis of organic-inorganic hybrid capsules for biotechnological applications.
Shi, Jiafu; Jiang, Yanjun; Wang, Xiaoli; Wu, Hong; Yang, Dong; Pan, Fusheng; Su, Yanlei; Jiang, Zhongyi
2014-08-07
Organic-inorganic hybrid capsules, which typically possess a hollow lumen and a hybrid wall, have emerged as a novel and promising class of hybrid materials and have attracted enormous attention. In comparison to polymeric capsules or inorganic capsules, the hybrid capsules combine the intrinsic physical/chemical properties of the organic and inorganic moieties, acquire more degrees of freedom to manipulate multiple interactions, create hierarchical structures and integrate multiple functionalities. Thus, the hybrid capsules exhibit superior mechanical strength (vs. polymeric capsules) and diverse functionalities (vs. inorganic capsules), which may give new opportunities to produce high-performance materials. Much effort has been devoted to exploring innovative and effective methods for the synthesis of hybrid capsules that exhibit desirable performance in target applications. This tutorial review firstly presents a brief description of the capsular structure and hybrid materials in nature, then classifies the hybrid capsules into molecule-hybrid capsules and nano-hybrid capsules based upon the size of the organic and inorganic moieties in the capsule wall, followed by a detailed discussion of the design and synthesis of the hybrid capsules. For each kind of hybrid capsule, the state-of-the-art synthesis methods are described in detail and a critical comment is embedded. The applications of these hybrid capsules in biotechnological areas (biocatalysis, drug delivery, etc.) have also been summarized. Hopefully, this review will offer a perspective and guidelines for the future research and development of hybrid capsules.
Redell, L.A.; Gall, W.K.; Ross, R.M.; Dropkin, D.S.
2009-01-01
Oligostomis ocelligera (a phryganeid caddisfly) is reported for the first time from a degraded lotic systema first-order stream in north-central Pennsylvania that was severely impacted by acid mine drainage. Although uncommonly collected and poorly known, O. ocelligera maintained a substantial population in the mine discharge, free of competition from Plecoptera, Ephemeroptera, and other species of Trichoptera. It thrived under conditions of very low pH (2.583.13), high concentrations of sulfate (542 mg/L) and heavy metals (Fe 12 mg/L, Mn 14 mg/L, Al 16 mg/L), and a nearly uniform springbrook-like temperature regime. More than 350 larvae were collected from deposits of leaves and woody detritus in a pool 0.32 km downstream from the mine entrance over a two-year period. Measurement of head-capsule widths yielded a multimodal distribution with five peaks, corresponding to five instars, in conformity with Dyar's Law. Eighty-three egg masses were observed along the stream channel from 3 June to 12 November at a mean distance of 6.1 cm above the water surface in moist, protected locations such as under moss mats or in crevices of logs. Eggs began hatching by mid-summer, first-instar larvae were present in samples from AugustOctober, all five instars were represented in October, instars IIV were still present in December, but only instars IV and V were represented in samples collected from March to July. The extended periods of oviposition and larval recruitment, together with a remarkably protracted flight period of six months (29 April30 October), led to the conclusion that the population of O. ocelligera at the mine site exhibited an asynchronous univoltine life cycle. Measurement of the width of the anterior border of the frontoclypeal apotome confirmed Wiggins' proposal that this metric is useful for distinguishing final instar larvae of O. ocelligera from its only Nearctic congener, O. pardalis. Occupied pupal cases were found embedded in sodden logs from 8 April to 10 June. Pupae had mandibles reduced to membranous lobes. A silken mesh closing the anterior end case of the pupal case is reported for the first time in O. ocelligera, representing the third evolutionary reversal for this behavioral character in the phylogeny of phryganeid genera proposed by Wiggins. Adults exhibited only diurnal flight, and were absent from light traps deployed on five nights. Females displayed more cryptic behavior, and their wing pattern was distinctly duller in color than males.
Modular "plug-and-play" capsules for multi-capsule environment in the gastrointestinal tract.
Phee, S J; Ting, E K; Lin, L; Huynh, V A; Kencana, A P; Wong, K J; Tan, S L
2009-01-01
The invention of wireless capsule endoscopy has opened new ways of diagnosing and treating diseases in the gastrointestinal tract. Current wireless capsules can perform simple operations such as imaging and data collection (like temperature, pressure, and pH) in the gastrointestinal tract. Researchers are now focusing on adding more sophisticated functions such as drug delivery, surgical clips/tags deployment, and tissue samples collection. The finite on-board power on these capsules is one of the factors that limits the functionalities of these wireless capsules. Thus multiple application-specific capsules would be needed to complete an endoscopic operation. This would give rise to a multi-capsule environment. Having a modular "plug-and-play" capsule design would facilitate doctors in configuring multiple application-specific capsules, e.g. tagging capsule, for use in the gastrointestinal tract. This multi-capsule environment also has the advantage of reducing power consumption through asymmetric multi-hop communication.
A comparative study on liquid core formulation on the diameter on the alginate capsules
NASA Astrophysics Data System (ADS)
Ong, Hui-Yen; Lee, Boon-Beng; Radzi, AkmalHadi Ma'; Zakaria, Zarina; Chan, Eng-Seng
2015-08-01
Liquid core capsule has vast application in biotechnology related industries such as pharmaceutical, medical, agriculture and food. Formulation of different types of capsule was important to determine the performance of the capsule. Generally, the liquid core capsule with different formulations generated different size of capsule.Therefore, the aim of this project is to investigate the effect of different liquid core solution formulations on the diameter of capsule. The capsule produced by extruding liquid core solutions into sodium alginate solution. Three types of liquid core solutions (chitosan, xanthan gum, polyethylene glycol (PEG)) were investigated. The results showed that there is significant change in capsule diameter despite in different types of liquid core solution were used and a series of capsule range in diameter of 3.1 mm to 4.5 mm were produced. Alginate capsule with chitosan formulation appeared to be the largest capsule among all.
Flower-like Na2O nanotip synthesis via femtosecond laser ablation of glass
2012-01-01
The current state-of-the-art in nanotip synthesis relies on techniques that utilize elaborate precursor chemicals, catalysts, or vacuum conditions, and any combination thereof. To realize their ultimate potential, synthesized nanotips require simpler fabrication techniques that allow for control over their final nano-morphology. We present a unique, dry, catalyst-free, and ambient condition method for creating densely clustered, flower-like, sodium oxide (Na2O) nanotips with controllable tip widths. Femtosecond laser ablation of a soda-lime glass substrate at a megahertz repetition rate, with nitrogen flow, was employed to generate nanotips with base and head widths as small as 100 and 20 nm respectively, and lengths as long as 10 μm. Control of the nanotip widths was demonstrated via laser dwell time with longer dwell times producing denser clusters of thinner nanotips. Energy dispersive X-ray analysis reveals that nanotip composition is Na2O. A new formation mechanism is proposed, involving an electrostatic effect between ionized nitrogen and polar Na2O. The synthesized nanotips may potentially be used in antibacterial and hydrogen storage applications. PMID:22809176
Creating compact and microscale features in paper-based devices by laser cutting.
Mahmud, Md Almostasim; Blondeel, Eric J M; Kaddoura, Moufeed; MacDonald, Brendan D
2016-11-14
In this work we describe a fabrication method to create compact and microscale features in paper-based microfluidic devices using a CO 2 laser cutting/engraving machine. Using this method we are able to produce the smallest features with the narrowest barriers yet reported for paper-based microfluidic devices. The method uses foil backed paper as the base material and yields inexpensive paper-based devices capable of using small fluid sample volumes and thus small reagent volumes, which is also suitable for mass production. The laser parameters (power and laser head speed) were adjusted to minimize the width of hydrophobic barriers and we were able to create barriers with a width of 39 ± 15 μm that were capable of preventing cross-barrier bleeding. We generated channels with a width of 128 ± 30 μm, which we found to be the physical limit for small features in the chromatography paper we used. We demonstrate how miniaturizing of paper-based microfluidic devices enables eight tests on a single bioassay device using only 2 μL of sample fluid volume.
Swain, Paul; Toor, Arifa; Volke, Frank; Keller, Jutta; Gerber, Jeremy; Rabinovitz, Elisha; Rothstein, Richard I
2010-06-01
Remote manipulation of wireless capsule endoscopes might improve diagnostic accuracy and facilitate therapy. To test a new capsule-manipulation system. University hospital. A first-in-human study tested a new magnetic maneuverable wireless capsule in a volunteer. A wireless capsule endoscope was modified to include neodymium-iron-boron magnets. The capsule's magnetic switch was replaced with a thermal one and turned on by placing it in hot water. One imager was removed from the PillCam colon-based capsule, and the available space was used to house the magnets. A handheld external magnet was used to manipulate this capsule in the esophagus and stomach. The capsule was initiated by placing it in a microg of hot water. The capsule was swallowed and observed in the esophagus and stomach by using a gastroscope. Capsule images were viewed on a real-time viewer. The capsule was manipulated in the esophagus for 10 minutes. It was easy to make the capsule turn somersaults and to angulate at the cardioesophageal junction. In the stomach, it was easy to move the capsule back from the pylorus to the cardioesophageal junction and hold/spin the capsule at any position in the stomach. The capsule in the esophagus and stomach did not cause discomfort. Magnetic force varies with the fourth power of distance. This study suggests that remote manipulation of a capsule in the esophagus and stomach of a human is feasible and might enhance diagnostic endoscopy as well as enable therapeutic wireless capsule endoscopy. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Capsule Endoscope Aspiration after Repeated Attempts for Ingesting a Patency Capsule
Mannami, Tomohiko; Ikeda, Genyo; Seno, Satoru; Sonobe, Hiroshi; Fujiwara, Nobukiyo; Komoda, Minori; Edahiro, Satoru; Ohtawa, Yasuyuki; Fujimoto, Yoshimi; Sato, Naohiro; Kambara, Takeshi; Waku, Toshihiko
2015-01-01
Capsule endoscope aspiration into the respiratory tract is a rare complication of capsule endoscopy. Despite the potential seriousness of this complication, no accepted methods exist to accurately predict and therefore prevent it. We describe the case of an 85-year-old male who presented for evaluation of iron deficiency anemia. He complained of dysphagia while ingesting a patency capsule, with several attempts over a period of 5 min before he was successful. Five days later, he underwent capsule endoscopy, where he experienced similar symptoms in swallowing the capsule. The rest of the examination proceeded uneventfully. On reviewing the captured images, the capsule endoscope was revealed to be aspirated, remaining in the respiratory tract for approximately 220 s before images of the esophagus and stomach appeared. To our knowledge, this is the first documented case of a patient who experienced capsule endoscope aspiration after ingestion of a patency capsule. This case suggests that repeated attempts required for ingesting the patency capsule can predict capsule endoscope aspiration. We presume that paying sufficient attention to the symptoms of a patient who ingests a patency capsule could help us prevent serious complications such as aspiration of the capsule endoscope. In addition, this experience implies the potential risk for ingesting the patency capsule. We must be aware that the patency capsule could also be aspirated and there may be more unrecognized aspiration cases. PMID:26600772
Capsule Endoscope Aspiration after Repeated Attempts for Ingesting a Patency Capsule.
Mannami, Tomohiko; Ikeda, Genyo; Seno, Satoru; Sonobe, Hiroshi; Fujiwara, Nobukiyo; Komoda, Minori; Edahiro, Satoru; Ohtawa, Yasuyuki; Fujimoto, Yoshimi; Sato, Naohiro; Kambara, Takeshi; Waku, Toshihiko
2015-01-01
Capsule endoscope aspiration into the respiratory tract is a rare complication of capsule endoscopy. Despite the potential seriousness of this complication, no accepted methods exist to accurately predict and therefore prevent it. We describe the case of an 85-year-old male who presented for evaluation of iron deficiency anemia. He complained of dysphagia while ingesting a patency capsule, with several attempts over a period of 5 min before he was successful. Five days later, he underwent capsule endoscopy, where he experienced similar symptoms in swallowing the capsule. The rest of the examination proceeded uneventfully. On reviewing the captured images, the capsule endoscope was revealed to be aspirated, remaining in the respiratory tract for approximately 220 s before images of the esophagus and stomach appeared. To our knowledge, this is the first documented case of a patient who experienced capsule endoscope aspiration after ingestion of a patency capsule. This case suggests that repeated attempts required for ingesting the patency capsule can predict capsule endoscope aspiration. We presume that paying sufficient attention to the symptoms of a patient who ingests a patency capsule could help us prevent serious complications such as aspiration of the capsule endoscope. In addition, this experience implies the potential risk for ingesting the patency capsule. We must be aware that the patency capsule could also be aspirated and there may be more unrecognized aspiration cases.
Impact of Increased Football Field Width on Player High-Speed Collision Rate.
Joseph, Jacob R; Khalsa, Siri S; Smith, Brandon W; Park, Paul
2017-07-01
High-acceleration head impact is a known risk for mild traumatic brain injury (mTBI) based on studies using helmet accelerometry. In football, offensive and defensive players are at higher risk of mTBI due to increased speed of play. Other collision sport studies suggest that increased playing surface size may contribute to reductions in high-speed collisions. We hypothesized that wider football fields lead to a decreased rate of high-speed collisions. Computer football game simulation was developed using MATLAB. Four wide receivers were matched against 7 defensive players. Each offensive player was randomized to one of 5 typical routes on each play. The ball was thrown 3 seconds into play; ball flight time was 2 seconds. Defensive players were delayed 0.5 second before reacting to ball release. A high-speed collision was defined as the receiver converging with a defensive player within 0.5 second of catching the ball. The simulation counted high-speed collisions for 1 team/season (65 plays/game for 16 games/season = 1040 plays/season) averaged during 10 seasons, and was validated against existing data using standard field width (53.3 yards). Field width was increased in 1-yard intervals up to 58.3 yards. Using standard field width, 188 ± 4 high-speed collisions were seen per team per season (18% of plays). When field width increased by 3 yards, high-speed collision rate decreased to 135 ± 3 per team per season (28% decrease; P < 0.0001). Even small increases in football field width can lead to substantial decline in high-speed collisions, with potential for reducing instances of mTBI in football players. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Guven, A.; Hassan, M.; Sabir, Shahin
2013-09-01
This study investigates the hydraulic characteristics of simultaneous flow over broad crested weir and through box (square) culverts experimentally. The variation of discharge coefficient (Cd) of the combined structure with various affective parameters such as upstream head, length of culvert, culvert inlet shape, culvert internal dimension, weir crest height, weir side slope angle, and weir width was analyzed. For this purpose 12 glass models of combined broad crested weirs and box culverts were manufactured and tested in a laboratory flume of 12 m. Discharge coefficient predicting equations were developed as a function of the dimensionless terms. The overall results showed that Cd increases as the ratio of the total head of water above the weir crest to the height of the weir crest H/P increases for all the models and for each flow state (weir and combined). Cd values increased as the head increased for all the models tested as culvert flow only, and also with decreasing of the angle between crest of the weir with the sides.
Plasticity in host utilization by two host-associated populations of Aphis gossypii Glover.
Barman, A K; Gadhave, K R; Dutta, B; Srinivasan, R
2018-06-01
Biological and morphological plasticity in polyphagous insect herbivores allow them to exploit diverse host plant species. Geographical differences in resource availability can lead to preferential host exploitation and result in inconsistent host specialization. Biological and molecular data provide insights into specialization and plasticity of such herbivore populations. In agricultural landscapes, Aphis gossypii encounters several crop and non-crop hosts, which exist in temporal and spatial proximity. We investigated the host-specialization of two A. gossypii host-associated populations (HAPs), which were field collected from cotton and squash (cotton-associated population and melon-associated population), and later maintained separately in the greenhouse. The two aphid populations were exposed to seven plant species (cotton, okra, watermelon, squash, cucumber, pigweed, and morning glory), and evaluated for their host utilization plasticity by estimating aphid's fitness parameters (nymphal period, adult period, fecundity, and intrinsic rate of increase). Four phenotypical characters (body length, head capsule width, hind tibia length and cornicle length) were also measured from the resulting 14 different HAP × host plant combinations. Phylogenetic analysis of mitochondrial COI sequences showed no genetic variation between the two HAPs. Fitness parameters indicated a significant variation between the two aphid populations, and the variation was influenced by host plants. The performance of melon-aphids was poor (up to 89% reduction in fecundity) on malvaceous hosts, cotton and okra. However, cotton-aphids performed better on cucurbitaceous hosts, squash and watermelon (up to 66% increased fecundity) compared with the natal host, cotton. Both HAPs were able to reproduce on two weed hosts. Cotton-aphids were smaller than melon-aphids irrespective of their host plants. Results from this study suggest that the two HAPs in the study area do not have strict host specialization; rather they exhibit plasticity in utilizing several hosts. In this scenario, it is unlikely that host-associated A. gossypii populations would evolve into host-specific biotypes.
Neoh, Kok-Boon; Lee, Chow-Yang
2011-01-01
The larval parasitoid Verticia fasciventris Malloch (Diptera: Calliphoridae) develops in the head of soldiers of the fungus-growing termite Macrotermes carbonarius (Hagen) (Isoptera: Termitidae). Morphological and behavioral changes in the host were evaluated and the termite castes and stages that were parasitized were identified. The larval emergence process is also described and possible mechanisms for the parasitoid fly's entry into the host body are discussed based on qualitative observations. Only a single larva per host was found. The mature larva pupated outside the host's body by exiting between the abdominal cerci. Parasitized soldiers possess a short and square-shaped head capsule, a pair of notably short mandibles, and a pair of 18-segmented antennae. Although parasitized soldiers were statistically less aggressive than healthy soldiers (P < 0.05), they expressed varying levels of aggression. Both minor and major soldiers can be parasitized and based on evidence from presoldiers, parasitization may begin during the precursor stages of soldiers. However, the stage at which parasitism first occurs has not been determined. PMID:21861651
Capsule enteroscopy; Wireless capsule endoscopy; Video capsule endoscopy (VCE); Small bowel capsule endoscopy (SBCE) ... a computer and software turns them into a video. Your provider watches the video to look for ...
Curatolo, William; Liu, Ping; Johnson, Barbara A; Hausberger, Angela; Quan, Ernest; Vendola, Thomas; Vatsaraj, Neha; Foulds, George; Vincent, John; Chandra, Richa
2011-07-01
Commercial azithromycin gelatin capsules (Zithromax®) are known to be bioequivalent to commercial azithromycin tablets (Zithromax®) when dosed in the fasted state. These capsules exhibit a reduced bioavailability when dosed in the fed state, while tablets do not. This gelatin capsule negative food effect was previously proposed to be due to slow and/or delayed capsule disintegration in the fed stomach, resulting in extended exposure of the drug to gastric acid, leading to degradation to des-cladinose-azithromycin (DCA). Azithromycin gelatin capsules were formulated with "superdisintegrants" to provide fast-dissolving capsules, and HPMC capsule shells were substituted for gelatin capsule shells, in an effort to eliminate the food effect. Healthy volunteers were dosed with these dosage forms under fasted and fed conditions; pharmacokinetics were evaluated. DCA pharmacokinetics were also evaluated for the HPMC capsule subjects. In vitro disintegration of azithromycin HPMC capsules in media containing food was evaluated and compared with commercial tablets and commercial gelatin capsules. When the two fast-dissolving capsule formulations were dosed to fed subjects, the azithromycin AUC was 38.9% and 52.1% lower than after fasted-state dosing. When HPMC capsules were dosed to fed subjects, the azithromycin AUC was 65.5% lower than after fasted-state dosing. For HPMC capsules, the absolute fasting-state to fed-state decrease in azithromycin AUC (on a molar basis) was similar to the increase in DCA AUC. In vitro capsule disintegration studies revealed extended disintegration times for commercial azithromycin gelatin capsules and HPMC capsules in media containing the liquid foods milk and Ensure®. Interaction of azithromycin gelatin and HPMC capsules with food results in slowed disintegration in vitro and decreased bioavailability in vivo. Concurrent measurement of serum azithromycin and the acid-degradation product DCA demonstrates that the loss of azithromycin bioavailability in the fed state is largely (and probably entirely) due to gastric degradation to DCA. Capsules can provide a useful and elegant dosage form for almost all drugs, but may result in a negative food effect for drugs as acid-labile as azithromycin.
Rawlings, T A
1990-12-01
Intraspecific variation in the morphology of egg capsules is ideal for assessing the costs and benefits of encapsulation, yet little is known about the extent of such variation among populations of a single species. In the present study, I compared capsule morphology among three populations of the intertidal gastropod, Nucella emarginata. Significant differences were found both in capsule wall thickness and capsule strength. Mean capsule wall thickness varied as much as 25% among populations, with the dry weight of capsular cases differing accordingly. Capsule strength, measured as resistance to puncturing and squeezing forces, also varied among populations, but did not directly reflect differences in capsule wall thickness. Despite extensive variation in capsule morphology within this species, the number and size of eggs contained within capsules of equal volume did not differ significantly among populations. I also compared the type of capsule-eating predators that were present at each site. Shore crabs, Hemigrapsus spp., were abundant at all three sites; however, the predatory isopods Idotea wosnesenskii were only present at sites containing relatively thick-walled capsules. Although Hemigrapsus and Idotea were able to chew through both thick- and thin-walled capsules, laboratory experiments revealed that Idotea preferentially opened thin-walled capsules. These results suggest that variation in capsule morphology among populations of N. emarginata may, at least in part, reflect selection for the protection of embryos against predation.
Magnetocardiogram measured by fundamental mode orthogonal fluxgate array
NASA Astrophysics Data System (ADS)
Karo, Hikaru; Sasada, Ichiro
2015-05-01
Magnetocardiography (MCG) of healthy volunteers has been measured by using a fundamental mode orthogonal fluxgate magnetometer array of 32 channels in a magnetic shielded room (MSR). Sensor heads, which are employed, consist of a 45 mm long U-shaped amorphous wire core and a 1000-turn solenoid pick-up coil of 30 mm in length and 3 mm in outer diameter. The excitation current of 100 kHz with large dc bias current is fed directly into wire cores, which are connected in series, whereas the signal detection circuit is provided to each of the sensor heads. A special technique to avoid mutual interaction between sensor heads is implemented, where all the sensor heads are excited synchronously by using a single ac source. A 2-D array having 32 sensors with 4 cm grid spacing was used to measure MCG signals inside an MSR. Measured data from each channel were first filtered (0.16-100 Hz pass band), then averaged for 2 min synchronously with electrocardiogram's peaks taken from both hands. Noise remaining after the average is about 1.8 pTrms for the band-width of 0.16-100 Hz. The QRS complex and the T-wave are clearly detected.
NASA Astrophysics Data System (ADS)
Vogler, Christoph; Abert, Claas; Bruckner, Florian; Suess, Dieter
2017-05-01
Curvatures of bit transitions on granular media are a serious problem for the read-back process. We address this fundamental issue and propose a possibility to efficiently reduce transition curvatures with state-of-the-art heat-assisted magnetic recording heads. We compare footprints of conventional with those of the proposed head design on different media, consisting of exchange coupled and single phase grains. Additionally, we investigate the impact of various recording parameters, such as the full width at half maximum (FWHM) of the applied heat pulse and the coercivity gradient near the write temperature of the recording grains. The footprints are calculated with a coarse grained model, based on the Landau-Lifshitz-Bloch equation. The presented simulations show a transition curvature reduction of up to 40%, in the case of a medium with exchange coupled grains and a heat pulse with a FWHM of 40 nm. We further give the reason for the straightening of the bit transitions, by means of basic considerations with regard to the effective recording time window of the write process. Besides the transition curvature reduction, the proposed head design yields an improvement of the transition jitter in both down-track and off-track directions.
Kemp, A
2017-02-01
Three systems, two sensory and one protective, are present in the skin of the living Australian lungfish, Neoceratodus forsteri, and in fossil lungfish, and the arrangement and innervation of the sense organs is peculiar to lungfish. Peripheral branches of nerves that innervate the sense organs are slender and unprotected, and form before any skeletal structures appear. When the olfactory capsule develops, it traps some of the anterior branches of cranial nerve V, which emerged from the chondrocranium from the lateral sphenotic foramen. Cranial nerve I innervates the olfactory organ enclosed within the olfactory capsule and cranial nerve II innervates the eye. Cranial nerve V innervates the sense organs of the snout and upper lip, and, in conjunction with nerve IX and X, the sense organs of the posterior and lateral head. Cranial nerve VII is primarily a motor nerve, and a single branch innervates sense organs in the mandible. There are no connections between nerves V and VII, although both emerge from the brain close to each other. The third associated system consists of lymphatic vessels covered by an extracellular matrix of collagen, mineralised as tubules in fossils. Innervation of the sensory organs is separate from the lymphatic system and from the tubule system of fossil lungfish. Copyright © 2016 Elsevier Ltd. All rights reserved.
Competition of wormholes during the evolution of cave passages
NASA Astrophysics Data System (ADS)
Gabrovsek, Franci; Dreybrodt, Wolfgang
2017-04-01
Reactive fronts in two-dimensional plane parallel fractures, with constant head difference between input and output and with diffusion controlled first order reaction rates R = keff ṡ (Ceq - C), where keff = k ṡ (1 + ka/6D)-1, are instable to infinitesimal perturbations in fracture aperture width (1), causing spontaneous fingering of the reactive front resulting in the formation of wormholes. C is the actual concentration and Ceq the equilibrium concentration, a, is the actual aperture width of the fracture , and D the constant of molecular diffusion. Fingering happens also in plane-parallel rough fractures where it is triggered by the existence of statistically more favorable pathways. The same behavior is observed in rectangular two-dimensional networks of "one-dimensional" smooth fractures used in modeling the evolution of caves in soluble rock (2). Here the formation of caves can be regarded as the evolution of wormholes along the two-dimensional network. Once fingering has been triggered, either by instability or by roughness, many small fingers compete with each other and only a few survive. Here we investigate the competition between two seeded fingers in initially homogeneous fracture networks with identical aperture width of all fractures and also in inhomogeneous ones where the aperture widths are distributed log normally. In both cases our modeling reveals the rules of competition: By instability one of the fingers grows faster than its competitor therefore penetrating somewhat deeper. As a consequence the hydraulic head at its tip is higher than that close to the tip of the shorter finger. Therefore the fractures connecting the tip regions of both fingers carry flow from the deep finger to the tip region of its competitor. This cross-flow is replaced by increasing inflow of aggressive solution into the input of the winner, enhancing further dissolution and growth. On the other hand the cross-flow increases the head at the tip of the losing finger, and consequently decreases inflow of aggressive solution into it, thus inhibiting its further evolution. This mechanism supports further growth of the winner (wormhole) and stops the growth of its competitor. Similar competition happens in the case of several fingers competing. In any case we observe flow from the winning fingers to the loosing ones. The communication between the competitors is always established by cross flow between its tip regions. We will present various scenarios of wormhole formation, which demonstrate details of the competition of fingers arising from either the reactive instability or from the statistical distribution of fracture aperture widths. In conclusion we find that the initiation of wormholes results either from instability or from the statistical distribution of favorable pathways. Once growth of fingers has been initiated the evolution of the wormhole patterns becomes deterministic. (1) Szymczak, P., and A.J.C. Ladd (2011), The initial stages of cave formation: Beyond the one-dimensional paradigm, Earth Planet. Sci. Lett. 301, 424-432 (2) Dreybrodt, W., Gabrovšek, F., Romanov, D.(2005) Processes of Speleogenesis: A Modeling Approach. ZRC Publishing, Karst Research Institute at ZRC SAZU, Ljubljana
Ziajahromi, Shima; Kumar, Anupama; Neale, Peta A; Leusch, Frederic D L
2018-05-01
Microplastics are a widespread environmental pollutant in aquatic ecosystems and have the potential to eventually sink to the sediment, where they may pose a risk to sediment-dwelling organisms. While the impacts of exposure to microplastics have been widely reported for marine biota, the effects of microplastics on freshwater organisms at environmentally realistic concentrations are largely unknown, especially for benthic organisms. Here we examined the effects of a realistic concentration of polyethylene microplastics in sediment on the growth and emergence of a freshwater organism Chironomus tepperi. We also assessed the influence of microplastic size by exposing C. tepperi larvae to four different size ranges of polyethylene microplastics (1-4, 10-27, 43-54 and 100-126 μm). Exposure to an environmentally relevant concentration of microplastics, 500 particles/kg sediment , negatively affected the survival, growth (i.e. body length and head capsule) and emergence of C. tepperi. The observed effects were strongly dependent on microplastic size with exposure to particles in the size range of 10-27 μm inducing more pronounced effects. While growth and survival of C. tepperi were not affected by the larger microplastics (100-126 μm), a significant reduction in the number of emerged adults was observed after exposure to the largest microplastics, with the delayed emergence attributed to exposure to a stressor. While scanning electron microscopy showed a significant reduction in the size of the head capsule and antenna of C. tepperi exposed to microplastics in the 10-27 μm size range, no deformities to the external structure of the antenna and mouth parts in organisms exposed to the same size range of microplastics were observed. These results indicate that environmentally relevant concentrations of microplastics in sediment induce harmful effects on the development and emergence of C. tepperi, with effects greatly dependent on particle size. Copyright © 2018 Elsevier Ltd. All rights reserved.
A new species of Lobocheilos (Teleostei: Cyprinidae) from East Kalimantan, Indonesian Borneo.
Ciccotto, Patrick J; Tan, Heok Hui
2018-03-22
Lobocheilos aurolineatus, new species, is described from the Mahakam River basin in East Kalimantan, Indonesian Borneo. It is distinguished from all other species of Lobocheilos except for L. ixocheilos and L. tenura in having one pair of barbels (maxillary) and by the presence of a broad, black midlateral stripe, approximately ¾ scale height in thickness, extending from the operculum to the caudal-peduncle base. Lobocheilos aurolineatus differs from both species in possessing a thin cream to yellow stripe on the anterior ⅔ of the flank, separating the black midlateral stripe from the brown dorso-lateral scales, and by a smaller mouth width (23.5-29.9% head length in L. aurolineatus vs. 32.1-45.0% and 34.4-46.4% head length in L. ixocheilos and L. tenura, respectively).
Retention of the capsule endoscope: a single-center experience of 1000 capsule endoscopy procedures.
Li, Feng; Gurudu, Suryakanth R; De Petris, Giovanni; Sharma, Virender K; Shiff, Arthur D; Heigh, Russell I; Fleischer, David E; Post, Janice; Erickson, Paula; Leighton, Jonathan A
2008-07-01
Retention of the video capsule is the most significant complication associated with capsule endoscopy (CE). There are limited data on incidence, risk factors, and outcomes of capsule retention. We aimed to determine the incidence of capsule retention and to investigate the causes and clinical outcomes of capsule retention. Single tertiary referral medical center. All patients who underwent CE for suspected small bowel disease from June 2002 to March 2006. Retrospective case series. Capsule retention occurred in 1.4% of our patients (14/1000). Eleven patients failed to pass the capsule because of nonsteroidal anti-inflammatory drug (NSAID) enteropathy (diaphragm disease). One patient had capsule retention from an obstructing carcinoid tumor. Metastatic ovarian cancer with invasion of the ileum was the cause of retention in another patient. One patient who did not have surgical removal of the capsule because of loss of follow-up had retention caused by a small-bowel tumor suspicious for carcinoid tumor on CT enterography. All patients remained "asymptomatic" from the retained capsules. Thirteen patients underwent elective partial small-bowel resection and capsule removal. No deaths were associated with these surgeries. Eleven patients recovered promptly, whereas 2 patients had mild postoperative ileus. Retrospective study. Retention of the capsule endoscope appears to be infrequent. The most common cause is diaphragm disease resulting from NSAIDs in this study population. In most cases, capsule retention is asymptomatic, and it usually leads to surgical removal, which appears safe and also identifies and treats the underlying small-bowel condition.
Filip, Dobromir; Yadid-Pecht, Orly; Muench, Gregory; Mintchev, Martin P; Andrews, Christopher N
2013-02-01
Capsule endoscopy is a noninvasive method for examining the small intestine. Recently, this method has been used to visualize the colon. However, the capsule often tumbles in the wider colon lumen, resulting in potentially missed pathology. In addition, the capsule does not have the ability to distend collapsed segments of the organ. Self-stabilizing capsule endoscopy is a new method of visualizing the colon without tumbling and with the ability to passively distend colon walls. To quantitatively compare the detection rate of intraluminal suture marker lesions for colonoscopy by using a custom-modified, self-stabilizing capsule endoscope (SCE); an unmodified capsule endoscope (CE) of the same brand; and a standard colonoscope. Four mongrel dogs underwent laparotomy and the implantation of 5 to 8 suture markers to approximate colon lesions. Each dog had both capsule endoscopy and self-stabilizing capsule endoscopy, administered consecutively in random order. In each case, the capsule was inserted endoscopically into the proximal lumen of the colon followed by pharmacologically induced colon peristalsis to propel it distally through the colon. Blinded standard colonoscopy was performed by an experienced gastroenterologist after the capsule endoscopies. Experimental study in a live canine model. Four dogs. Laparotomy, capsule endoscopy, colonoscopy. Comparison of the marker detection rate of the SCE to that of the unmodified MiroCam CE and a colonoscope. The average percentages of the marker detection rate for unmodified capsule endoscopy, self-stabilizing capsule endoscopy, and colonoscopy, respectively, were 31.1%, 86%, and 100% (P < .01), with both self-stabilizing capsule endoscopy and colonoscopy performing significantly better than the unmodified capsule endoscopy. Acute canine model, suture markings poorly representative of epithelial polyps, limited number of animals. The proposed self-stabilizing capsule endoscope delivered a significant improvement in detection rates of colon suture markings when compared with the unmodified capsule endoscope. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Commissioning of a Varian Clinac iX 6 MV photon beam using Monte Carlo simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dirgayussa, I Gde Eka, E-mail: ekadirgayussa@gmail.com; Yani, Sitti; Haryanto, Freddy, E-mail: freddy@fi.itb.ac.id
2015-09-30
Monte Carlo modelling of a linear accelerator is the first and most important step in Monte Carlo dose calculations in radiotherapy. Monte Carlo is considered today to be the most accurate and detailed calculation method in different fields of medical physics. In this research, we developed a photon beam model for Varian Clinac iX 6 MV equipped with MilleniumMLC120 for dose calculation purposes using BEAMnrc/DOSXYZnrc Monte Carlo system based on the underlying EGSnrc particle transport code. Monte Carlo simulation for this commissioning head LINAC divided in two stages are design head Linac model using BEAMnrc, characterize this model using BEAMDPmore » and analyze the difference between simulation and measurement data using DOSXYZnrc. In the first step, to reduce simulation time, a virtual treatment head LINAC was built in two parts (patient-dependent component and patient-independent component). The incident electron energy varied 6.1 MeV, 6.2 MeV and 6.3 MeV, 6.4 MeV, and 6.6 MeV and the FWHM (full width at half maximum) of source is 1 mm. Phase-space file from the virtual model characterized using BEAMDP. The results of MC calculations using DOSXYZnrc in water phantom are percent depth doses (PDDs) and beam profiles at depths 10 cm were compared with measurements. This process has been completed if the dose difference of measured and calculated relative depth-dose data along the central-axis and dose profile at depths 10 cm is ≤ 5%. The effect of beam width on percentage depth doses and beam profiles was studied. Results of the virtual model were in close agreement with measurements in incident energy electron 6.4 MeV. Our results showed that photon beam width could be tuned using large field beam profile at the depth of maximum dose. The Monte Carlo model developed in this study accurately represents the Varian Clinac iX with millennium MLC 120 leaf and can be used for reliable patient dose calculations. In this commissioning process, the good criteria of dose difference in PDD and dose profiles were achieve using incident electron energy 6.4 MeV.« less
Ji, Xiang; Qiu, Qing-Bo; Diong, Cheong-Hoong
2002-06-01
We incubated eggs of Calotes versicolor at four constant temperatures ranging from 24 degrees C to 33 degrees C to assess the effects of incubation temperature on hatching success, embryonic use of energy, and hatchling phenotypes that are likely to affect fitness. All viable eggs increased in mass throughout incubation due to absorption of water, and mass gain during incubation was dependent on initial egg mass and incubation temperature. The average duration of incubation at 24 degrees C, 27 degrees C, 30 degrees C, and 33 degrees C was 82.1 days, 60.5 days, 51.4 days, and 50.3 days, respectively. Incubation temperature affected hatching success, energy expenditure for embryonic development, and several hatchling traits examined, but it did not affect the sex ratio of hatchlings. Hatching success was lowest (3.4%) at 33 degrees C, but a higher incidence of deformed embryos was recorded from eggs incubated at this temperature compared to eggs incubated at lower temperatures. Most of the deformed embryos died at the last stage of incubation. Energy expenditure for embryonic development was, however, higher in eggs incubated at 33 degrees C than those similarly incubated at lower temperatures. A prolonged exposure of eggs of C. versicolor at 33 degrees C appears to have an adverse and presumably lethal effect on embryonic development. Hatching success at 24 degrees C was also low (43.3%), but hatchlings incubated at 24 degrees C did not differ in any of the examined traits from those incubated at two intermediate temperatures (27 degrees C and 30 degrees C). Hatchlings incubated at 33 degrees C were smaller (snout-vent length, SVL) than those incubated at lower incubation temperatures and had larger mass residuals (from the regression on SVL) as well as shorter head length, hindlimb length, tympanum diameter, and eye diameter relative to SVL. Hatchlings from 33 degrees C had significantly lower scores on the first axis of a principal component analysis representing mainly SVL-free head size (length and width) and fore- and hindlimb lengths, but they had significantly higher scores on the second axis mainly representing SVL-free wet body mass. Variation in the level of fluctuating asymmetry in eye diameter associated with incubation temperatures was quite high, and it was clearly consistent with the prediction that environmental stress associated with the highest incubation temperatures might produce the highest level of asymmetry. Newly emerged hatchlings exhibited sexual dimorphism in head width, with male hatchlings having larger head width than females. Copyright 2002 Wiley-Liss, Inc.
Numerical Modeling of Scour at the Head of a Vertical-Wall Breakwater in Waves
NASA Astrophysics Data System (ADS)
Baykal, C.; Balcı, H. B.; Sumer, B. M.; Fuhrman, D. R.
2017-12-01
This study presents a 3D numerical modeling study on the flow and scour at the head of a vertical-wall breakwater in regular waves. The numerical model utilized in the study is based on that given by Jacobsen (2011). The present model has been applied successfully to the scour and backfilling beneath submarine pipelines by Fuhrman et al. (2014), and around a vertical cylindrical pile mounted on a horizontal plane sediment bed by Baykal et al. (2015, 2017). The model is composed of two main modules. The first module is the hydrodynamic model where Reynolds Averaged Navier Stokes (RANS) equations are solved with a k-ω turbulence closure. The second module is the morphologic model which comprises five sub-modules, namely; bed load, suspended load, sand slide, bed evolution and 3D mesh motion. The model is constructed in open-source CFD toolbox OpenFOAM. In this study, the model is applied to experimental data sets of Sumer and Fredsoe (1997) on the scour around a vertical-wall breakwater with a circular round head. Here, it is given the preliminary results of bed evolution of Test-8 of Sumer and Fredsoe (1997) in which a vertical-wall breakwater head with a width of B=140 mm is subjected to oscillatory flow with Tw=2.0 s and maximum orbital velocity at the bed Um=22cm/s, resulting in a Keulegan-Carpenter number, KC=3.14, close to KC experienced in real-life situations (KC = O(1)). The grain size is d=0.17 mm. The Shields parameter in the test case is given as θc=0.11, larger than the critical value for the initiation of motion implying that the scour is in the live-bed regime. The computational domain used in the simulations has the following dimensions: Length, l=40B, Width, w=20B, and Height, h=2B. The total number of cells is O(105) in the simulations. The scoured bed profile computed at the end of 3 periods of oscillatory flow of Test-8 is given in the figure below. The color scale in the figure is given for the ratio of bed elevation to the width of breakwater. Early results show that bed shear stress amplifications are as high as O(10) near the structure and the scoured bed profile looks similar in shape as observed in the experiments. The simulation results will be presented with special focus on the flow structures around the structure and the time scale of the scour development.
Almeida, F; Caldas, R; Corrêa, C; Rodrigues-Silva, R; Siqueira, N; Machado-Silva, J R
2013-12-01
The helminth fauna of Agouti paca (Linnaeus, 1766) has seldom been studied. In this paper, we report an unusual mixed infection of Echinococcus vogeli Rausch & Bernstein, 1972 and Calodium hepaticum (syn. Capillaria hepatica Bancroft, 1863) in free-ranging paca from a forested region in Acre (Brazil). Gross morphological examination revealed that paca liver contained multiple spherical to subspherical white or translucent lesions, which were isolated or frequently contiguous and partially covered by Glisson's capsule. Microscopic examination revealed unilocular cystic structures that contained abundant brood capsules in which numerous protoscolices budded from the inner surface. The protoscolices possessed rostellar hooks (33-41 μm in length), a morphological characteristic of the blade and calcareous corpuscles that is consistent with the metacestode E. vogeli. The diagnosis of C. hepaticum infection was based on the morphology and morphometry of the egg-shaped ellipsoids with bipolar plugs (44.8 ± 1.9 μm (length) × 24.4 ± 2.0 μm (width)) and liver histopathology. This finding expands the known range of C. hepaticum hosts in South America and, to the best of our knowledge, it is the first case of a mixed infection of E. vogeli and C. hepaticum. Furthermore, our data provide evidence that wild animal meat may be a source of C. hepaticum infection.
Baker, Lorina G; Specht, Charles A; Donlin, Maureen J; Lodge, Jennifer K
2007-05-01
Cryptococcus neoformans is an opportunistic fungal pathogen that causes cryptococcal meningoencephalitis, particularly in immunocompromised patients. The fungal cell wall is an excellent target for antifungal therapies as it is an essential organelle that provides cell structure and integrity, it is needed for the localization or attachment of known virulence factors, including the polysaccharide capsule, melanin, and phospholipase, and it is critical for host-pathogen interactions. In C. neoformans, chitosan produced by the enzymatic removal of acetyl groups from nascent chitin polymers has been implicated as an important component of the vegetative cell wall. In this study, we identify four putative chitin/polysaccharide deacetylases in C. neoformans. We have demonstrated that three of these deacetylases, Cda1, Cda2, and Cda3, can account for all of the chitosan produced during vegetative growth in culture, but the function for one, Fpd1, remains undetermined. The data suggest a model for chitosan production in vegetatively growing C. neoformans where the three chitin deacetylases convert chitin generated by the chitin synthase Chs3 into chitosan. Utilizing a collection of chitin/polysaccharide deacetylase deletion strains, we determined that during vegetative growth, chitosan helps to maintain cell integrity and aids in bud separation. Additionally, chitosan is necessary for maintaining normal capsule width and the lack of chitosan results in a "leaky melanin" phenotype. Our analysis indicates that chitin deacetylases and the chitosan made by them may prove to be excellent antifungal targets.
Henneberg, Maciej; Ulijaszek, Stanley J
2010-01-01
We explore relationships between BMI and skinfolds and anthropometric variables reflecting variation in lean body frame. Data on the middle class adult Australian women (n = 1260) collected in 2002 during a National Body Size and Shape Survey were used. Standard measurements of stature, weight, skeletal dimensions (shoulder width, hip width, chest width, and depth, limb lengths), circumferences of head, trunk, limbs and triceps, subscapular and abdominal skinfolds were taken. Techniques for measurements of skeletal frame minimized the inclusion of adipose tissue thickness. Analysis of variance and parametric and nonparametric correlations were used. Vertical dimensions show weak correlations with fatness, while body frame circumferences and transverse dimensions are consistently, significantly, and substantially correlated with fatness, each explaining from 3 to 44% of variation in skinfold thickness. Skeletal dimensions explain up to 50% of variation in skinfold thickness (multiple regression). Especially high correlations with skinfold thickness occur for chest width, depth, and hip width (r range from 0.42 to 0.66). Body frame dimensions reflect largely trunk volume and the trunk/limb proportions. Larger lean trunk size is associated with greater fatness. Since the size of the abdominal cavity, and thus the gastrointestinal system (GI), is reflected in the trunk size, we speculate that larger frame may predispose to obesity in two ways: (1) larger stomachs require greater bulk of food to produce feeling of satiety as mediated through antral distension, (2) larger GIs may absorb more nutrients. Frame size may help to detect the risk of obesity among young adults. 2009 Wiley-Liss, Inc.
Residual mercury content and leaching of mercury and silver from used amalgam capsules.
Stone, M E; Pederson, E D; Cohen, M E; Ragain, J C; Karaway, R S; Auxer, R A; Saluta, A R
2002-06-01
The objective of this investigation was to carry out residual mercury (Hg) determinations and toxicity characteristic leaching procedure (TCLP) analysis of used amalgam capsules. For residual Hg analysis, 25 capsules (20 capsules for one brand) from each of 10 different brands of amalgam were analyzed. Total residual Hg levels per capsule were determined using United States Environmental Protection Agency (USEPA) Method 7471. For TCLP analysis, 25 amalgam capsules for each of 10 brands were extracted using a modification of USEPA Method 1311. Hg analysis of the TCLP extracts was done with USEPA Method 7470A. Analysis of silver (Ag) concentrations in the TCLP extract was done with USEPA Method 6010B. Analysis of the residual Hg data resulted in the segregation of brands into three groups: Dispersalloy capsules, Group A, retained the most Hg (1.225 mg/capsule). These capsules were the only ones to include a pestle. Group B capsules, Valliant PhD, Optaloy II, Megalloy and Valliant Snap Set, retained the next highest amount of Hg (0.534-0.770 mg/capsule), and were characterized by a groove in the inside of the capsule. Group C, Tytin regular set double-spill, Tytin FC, Contour, Sybraloy regular set, and Tytin regular set single-spill retained the least amount of Hg (0.125-0.266 mg/capsule). TCLP analysis of the triturated capsules showed Sybraloy and Contour leached Hg at greater than the 0.2 mg/l Resource Conservation and Recovery Act (RCRA) limit. This study demonstrated that residual mercury may be related to capsule design features and that TCLP extracts from these capsules could, in some brands, exceed RCRA Hg limits, making their disposal problematic. At current RCRA limits, the leaching of Ag is not a problem.
Lake Erie Water Level Study. Appendix B. Regulatory Works.
1981-07-01
From Lake Erie to Strawberry Island, a distance of approximately 5 miles, the channel width varies from 9,000 feet at its funnel-shaped entrance to...boating. Downstream from Navy Island, boating is discouraged due to the danger of being swept over Niagara Falls. At Strawberry and Grand Islands, the...reach at the head of Niagara River. Extending from Buffalo Harbor to the river above Strawberry Island, the canal is separated from the river by a series
δ-Catenin Regulates Spine Architecture via Cadherin and PDZ-dependent Interactions.
Yuan, Li; Seong, Eunju; Beuscher, James L; Arikkath, Jyothi
2015-04-24
The ability of neurons to maintain spine architecture and modulate it in response to synaptic activity is a crucial component of the cellular machinery that underlies information storage in pyramidal neurons of the hippocampus. Here we show a critical role for δ-catenin, a component of the cadherin-catenin cell adhesion complex, in regulating spine head width and length in pyramidal neurons of the hippocampus. The loss of Ctnnd2, the gene encoding δ-catenin, has been associated with the intellectual disability observed in the cri du chat syndrome, suggesting that the functional roles of δ-catenin are vital for neuronal integrity and higher order functions. We demonstrate that loss of δ-catenin in a mouse model or knockdown of δ-catenin in pyramidal neurons compromises spine head width and length, without altering spine dynamics. This is accompanied by a reduction in the levels of synaptic N-cadherin. The ability of δ-catenin to modulate spine architecture is critically dependent on its ability to interact with cadherin and PDZ domain-containing proteins. We propose that loss of δ-catenin during development perturbs synaptic architecture leading to developmental aberrations in neural circuit formation that contribute to the learning disabilities in a mouse model and humans with cri du chat syndrome. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.
Protective Role of the Capsule and Impact of Serotype 4 Switching on Streptococcus mitis
Rukke, Håkon V.; Kalluru, Raja Sab; Repnik, Urska; Gerlini, Alice; José, Ricardo J.; Periselneris, Jimstan; Marshall, Helina; Griffiths, Gareth; Oggioni, Marco Rinaldo; Brown, Jeremy S.
2014-01-01
The polysaccharide capsule surrounding Streptococcus pneumoniae is essential for virulence. Recently, Streptococcus mitis, a human commensal and a close relative of S. pneumoniae, was also shown to have a capsule. In this study, the S. mitis type strain switched capsule by acquisition of the serotype 4 capsule locus of S. pneumoniae TIGR4, following induction of competence for natural transformation. Comparison of the wild type with the capsule-switching mutant and with a capsule deletion mutant showed that the capsule protected S. mitis against phagocytosis by RAW 264.7 macrophages. This effect was enhanced in the S. mitis strain expressing the S. pneumoniae capsule, which showed, in addition, increased resistance against early clearance in a mouse model of lung infection. Expression of both capsules also favored survival in human blood, and the effect was again more pronounced for the capsule-switching mutant. S. mitis survival in horse blood or in a mouse model of bacteremia was not significantly different between the wild type and the mutant strains. In all models, S. pneumoniae TIGR4 showed higher rates of survival than the S. mitis type strain or the capsule-switching mutant, except in the lung model, in which significant differences between S. pneumoniae TIGR4 and the capsule-switching mutant were not observed. Thus, we identified conditions that showed a protective function for the capsule in S. mitis. Under such conditions, S. mitis resistance to clearance could be enhanced by capsule switching to serotype 4, but it was enhanced to levels lower than those for the virulent strain S. pneumoniae TIGR4. PMID:24958712
Asymptomatic bronchial aspiration and prolonged retention of a capsule endoscope: a case report.
Pezzoli, Alessandro; Fusetti, Nadia; Carella, Alessandra; Gullini, Sergio
2011-08-02
Capsule endoscopy has, over the last few years, become a first-line test to visualize the mucosa of the small intestine. This technique is generally considered safe and does not cause discomfort for patients. However, although patients may have difficulty in swallowing the capsule, bronchial aspiration of a capsule endoscope is a very rare complication. We report the case of an 82-year-old man who experienced prolonged bronchial aspiration of a capsule endoscope without relevant symptoms, followed by a spontaneous return of the capsule to the gastrointestinal tract. An 82-year-old Caucasian man was referred to our unit from another local hospital to undergo capsule endoscopy. He swallowed the capsule without any apparent difficulties and did not show any overt symptoms. The following day, when we reviewed the capsule endoscopy images, we realized that the capsule was in the bronchial system and remained there for the duration of the study. An urgent X-ray of the chest confirmed the presence of the capsule in the left side of the bronchopulmonary tree. Two days later a repeat chest X-ray showed the capsule in the right bronchus. After two days the capsule was retrieved in the feces. Our patient remained asymptomatic during the entire admission period. Aspiration of a capsule endoscope is a rare complication; to the best of our knowledge this is the first reported case in which a capsule endoscope remained for six days in the bronchial system of a patient without causing airway compromise or pneumonitis and spontaneously returned to the gastrointestinal tract.
Oxygen Fugacity in Large Metal Capsules
NASA Astrophysics Data System (ADS)
Faul, U.; Cline, C. J., II; Jackson, I.; Berry, A.
2016-12-01
During experiments with iron bearing silicates, equilibration between metal capsules and sample interior depends on diffusion of Fe if the capsule composition is not initially in equilibrium with the sample composition. For example, placing Pt or Ni capsules in contact with Fe-bearing olivine leads to Fe-loss from the olivine. In a fully equilibrated system the Fe contents of coexisting metal capsule and olivine reflect the oxygen fugacity (fO2) of the system. Experiments were conducted with olivine encapsulated or wrapped in four different metals (Fe, Ni70Fe30, Ni and Pt) to determine the fO2 in the cm-sized samples used for deformation and seismic property experiments. Small Pt particles mixed with olivine powder were used as fO2 sensors in the interior of the capsules. The results show an ordering of the fO2 in the interior that is consistent with the enclosing metals, i.e. the fO2 is lowest in a Fe capsule and highest in a Pt capsule. However, fO2 values in the more oxidizing metal capsules are substantially below their respective metal-oxide buffers. For example, solgel olivine encapsulated in Ni has an oxygen fugacity that is more than three orders of magnitude below Ni-NiO at 1200C and 0.3 GPa. The fO2 in a capsule interior is therefore to some extent self-buffering and only moderately influenced by the composition of the capsule. While the Pt particles in the interior are equilibrated, Fe gradients from the interior up to the Pt and Ni sample-capsule interfaces show that Fe loss into the capsules is diffusion limited. The fO2 at the interface also has implications for the water retention in unbuffered capsules. We infer that relatively high fO2 and hence fH2O observed adjacent to Pt capsules enables retention of water in these capsules, but the fO2 adjacent to Ni capsules is too low and water is lost.
Dodson, Christopher C; Nho, Shane J; Williams, Riley J; Altchek, David W
2008-10-01
Arthroscopy of the elbow was originally considered to be an unsafe procedure because of the small size of the elbow joint capsule and its proximity to several crucial neurovascular structures. Over the past decade, however, the procedure has become safer and more effective. These improvements can be attributed to a better understanding of elbow anatomy and of the disorders about the elbow as well as to advances in arthroscopic equipment and surgical technique. The most common indications for elbow arthroscopy include removal of loose bodies, synovectomy, débridement and/or excision of osteophytes, capsular release, and the assessment and treatment of osteochondritis dissecans. More recent advances have expanded the indications of elbow arthroscopy to include fracture management (eg, radial head fractures) and the treatment of lateral epicondylitis.
[The occurance lead and cadmium in hip joint in aspect of exposure on tobacco smoke].
Bogunia, Mariusz; Brodziak-Dopierała, Barbara; Kwapuliński, Jerzy; Ahnert, Bozena; Kowol, Jolanta; Nogaj, Ewa
2008-01-01
The objective of this study was qualification of content cadmium and lead in selected elements of the hip joint in aspect of tobacco smoking. The material for the research were 5 elements of hip joint (articular cartilage, trabecular bone and cortical bone femur head, fragment articular capsule and fragment trabecular bone from region intertrochanteric femoral bone), obtained intraoperatively during endoprothesoplastic surgeries. The samples come from habitants of Upper Silesian Region. Determination of trace elements contents were performed by ASA method (Pye Unicam SP-9) in acetylene-oxygen flame. Higher contents of lead were observed for smoking people, however in case of cadmium the differences of this element were not statistical essential between smokers and non-smokers.
Normal development and growth of the human neurocranium and cranial base.
Friede, H
1981-01-01
The literature on normal development and growth of certain areas of the human head is reviewed, starting with the early induction of the desmal neurocranium. the development of the brain capsule with its dural reinforcement bands and their connection with the basicranium is discussed, as is the primordial chondrocranium, including its bone replacement. Growth of the calvaria and the three cranial fossae is also analysed. Special interest is focused on the anterior fossa, as knowledge of the growth in this area is very important for an understanding of pathogenesis and possibilities of treating premature craniosynostosis. Finally it is stressed that close observation of the effects of treatment on this pathology may increase our knowledge of normal growth.
Chronic Ethanol During Adolescence Impacts Corticolimbic Dendritic Spines and Behavior.
Jury, Nicholas J; Pollack, Gabrielle A; Ward, Meredith J; Bezek, Jessica L; Ng, Alexandra J; Pinard, Courtney R; Bergstrom, Hadley C; Holmes, Andrew
2017-07-01
Risk for alcohol use disorders (AUDs) in adulthood is linked to alcohol drinking during adolescence, but understanding of the neural and behavioral consequences of alcohol exposure during adolescence remains incomplete. Here, we examined the neurobehavioral impact of adolescent chronic intermittent EtOH (CIE) vapor exposure in mice. C57BL/6J-background Thy1-EGFP mice were CIE-exposed during adolescence or adulthood and examined, as adults, for alterations in the density and morphology of dendritic spines in infralimbic (IL) cortex, prelimbic (PL) cortex, and basolateral amygdala (BLA). In parallel, adolescent- and adult-exposed C57BL/6J mice were tested as adults for 2-bottle EtOH drinking, sensitivity to EtOH intoxication (loss of righting reflex [LORR]), blood EtOH clearance, and measures of operant responding for food reward. CIE during adolescence decreased IL neuronal spine density and increased the head width of relatively wide-head IL and BLA spines, whereas CIE decreased head width of relatively narrow-head BLA spines. Adolescents had higher EtOH consumption prior to CIE than adults, while CIE during adulthood, but not adolescence, increased EtOH consumption relative to pre-CIE baseline. CIE produced a tolerance-like decrease in LORR sensitivity to EtOH challenge, irrespective of the age at which mice received CIE exposure. Mice exposed to CIE during adolescence, but not adulthood, required more sessions than AIR controls to reliably respond for food reward on a fixed-ratio (FR) 1, but not subsequent FR3, reinforcement schedule. On a progressive ratio reinforcement schedule, break point responding was higher in the adolescent- than the adult-exposed mice, regardless of CIE. Finally, footshock punishment markedly suppressed responding for reward in all groups. Exposure to CIE during adolescence altered dendritic spine density and morphology in IL and BLA neurons, in parallel with a limited set of behavioral alterations. Together, these data add to growing evidence that key corticolimbic circuits are vulnerable to the effects of alcohol during adolescence, with lasting, potentially detrimental, consequences for behavior. Copyright © 2017 by the Research Society on Alcoholism.
Chronic ethanol during adolescence impacts corticolimbic dendritic spines and behavior
Jury, Nicholas J.; Pollack, Gabrielle A.; Ward, Meredith J.; Bezek, Jessica L.; Ng, Alexandra J.; Pinard, Courtney R.; Bergstrom, Hadley C.; Holmes, Andrew
2017-01-01
Background Risk for alcohol use disorders (AUDs) is linked to alcohol drinking during adolescence, but understanding of the neural and behavioral consequences of alcohol exposure during adolescence remains incomplete. Here, we examined the neurobehavioral impact of adolescent chronic intermittent EtOH (CIE) vapor exposure in mice. Methods C57BL/6J-background Thy1-EGFP mice were CIE-exposed during adolescence or adulthood and examined, as adults, for alterations in the density and morphology of dendritic spines in infralimbic cortex (IL), prelimbic cortex (PL) and basolateral amygdala (BLA). In parallel, adolescent- and adult-exposed C57BL/6J mice were tested as adults for two-bottle EtOH drinking, sensitivity to EtOH intoxication (loss of righting reflex, LORR), blood EtOH clearance, and measures of operant responding for food reward. Results CIE during adolescence decreased IL neuronal spine density and increased the head-width of relatively wide-head IL and BLA spines, whereas CIE decreased head-width of relatively narrow-head BLA spines. Adolescents had higher EtOH consumption prior to CIE than adults, while CIE during adulthood, but not adolescence, increased EtOH consumption relative to pre-CIE baseline. CIE produced a tolerance-like decrease in LORR sensitivity to EtOH challenge, irrespective of the age at which mice received CIE exposure. Mice exposed to CIE during adolescence, but not adulthood, required more sessions than AIR controls to reliably respond for food reward on a fixed-ratio (FR1), but not subsequent FR3, reinforcement schedule. On a progressive ratio reinforcement schedule, breakpoint responding was higher in the adolescent- than the adult-exposed mice, regardless of CIE. Finally, footshock-punishment markedly suppressed responding for reward in all groups. Conclusions Exposure to CIE during adolescence altered dendritic spine density and morphology in IL and BLA neurons, in parallel with a limited set of behavioral alterations. Together, these data add to growing evidence that key corticolimbic circuits are vulnerable to the effects of alcohol during adolescence, with lasting, potentially detrimental, consequences for behavior. PMID:28614590
Motion of an elastic capsule in a square microfluidic channel.
Kuriakose, S; Dimitrakopoulos, P
2011-07-01
In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2) approach to the undisturbed average duct velocity and an additional pressure drop ΔP+ ~a(3)/h ~ a(5). By combining basic physical principles and geometric properties, we develop a theoretical analysis that explains the power laws we found for large capsules.
Pool Formation in Boulder-Bed Streams: Implications From 1-D and 2-D Numerical Modeling
NASA Astrophysics Data System (ADS)
Harrison, L. R.; Keller, E. A.
2003-12-01
In mountain rivers of Southern California, boulder-large roughness elements strongly influence flow hydraulics and pool formation and maintenance. In these systems, boulders appear to control the stream morphology by converging flow and producing deep pools during channel forming discharges. Our research goal is to develop quantitative relationships between boulder roughness elements, temporal patterns of scour and fill, and geomorphic processes that are important in producing pool habitat. The longitudinal distribution of shear stress, unit stream power and velocity were estimated along a 48 m reach on Rattlesnake Creek, using the HEC-RAS v 3.0 and River 2-D numerical models. The reach has an average slope of 0.02 and consists of a pool-riffle sequence with a large boulder constriction directly above the pool. Model runs were performed for a range of stream discharges to test if scour and fill thresholds for pool and riffle environments could be identified. Results from the HEC-RAS simulations identified that thresholds in shear stress, unit stream power and mean velocity occur above a discharge of 5.0 cms. Results from the one-dimensional analysis suggest that the reversal in competency is likely due to changes in cross-sectional width at varying flows. River 2-D predictions indicated that strong transverse velocity gradients were present through the pool at higher modeled discharges. At a flow of 0.5 cms (roughly 1/10th bankfull discharge), velocities are estimated at 0.6 m/s and 1.3 m/s for the pool and riffle, respectively. During discharges of 5.15 cms (approximate bankfull discharge), the maximum velocity in the pool center increased to nearly 3.0 m/s, while the maximum velocity over the riffle is estimated at approximately 2.5 cms. These results are consistent with those predicted by HEC-RAS, though the reversal appears to be limited to a narrow jet that occurs through the pool head and pool center. Model predictions suggest that the velocity reversal is produced by a boulder-bedrock constriction that rapidly decreases the channel width above the pool by roughly 25 percent. The width constriction creates highly turbulent flow capable of scouring bed material through the pool. The high velocity core that is produced through the pool center appears to be enhanced by the formation of a large eddy directly below the boulder. Values of unit stream power and shear stress indicate that the pool exit is an area of deposition of bed material due to a decrease in tractive force. The presence of a strong transverse velocity gradient suggests that only a portion of the flow is responsible for scouring bed material. After we eliminate the dead water zone, the lowest five percent of the velocity range, patterns of effective width between pools and riffles begin to emerge. The ratio of flow width between adjacent pools and riffles is one measure of flow convergence. At a discharge of 0.5 cms, the ratio of effective width between pools and riffles is roughly 1:1, implying that there is uniform flow with little flow convergence. At a discharge of 5.15 cms the width ratio between the pool and riffle is about 1:3, demonstrating the strong convergent flow patterns at the pool head. The observed effective width relationship suggests that when considering restoration designs, boulders should be placed in areas that replicate natural convergence and divergence patterns in order to maximize pool area and depth.
1959-09-08
Big Joe Capsule Launch Pad Activities: This film covers both the Big Joe and a Little Joe Project Mercury flight test with a research and development version of the Mercury capsule. Big Joe was an Atlas missile that successfully launched a boilerplate model of the Mercury capsule on September 9, 1959. The lower half of the capsule was created at NASA Lewis. The scenes include coverage of the assembly and erection of the boosters, delivery of the capsules, mating of the capsules to the boosters, prelaunch views of the capsule and boosters on launchers, mission control, the launches, and recovery.
21 CFR 520.1660b - Oxytetracycline hydrochloride capsules.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride capsules. 520.1660b... Oxytetracycline hydrochloride capsules. (a) Specifications. The drug is in capsule form with each capsule containing 125 or 250 milligrams of oxytetracycline hydrochloride. Oxytetracycline is the antibiotic...
Small intestinal model for electrically propelled capsule endoscopy
2011-01-01
The aim of this research is to propose a small intestine model for electrically propelled capsule endoscopy. The electrical stimulus can cause contraction of the small intestine and propel the capsule along the lumen. The proposed model considered the drag and friction from the small intestine using a thin walled model and Stokes' drag equation. Further, contraction force from the small intestine was modeled by using regression analysis. From the proposed model, the acceleration and velocity of various exterior shapes of capsule were calculated, and two exterior shapes of capsules were proposed based on the internal volume of the capsules. The proposed capsules were fabricated and animal experiments were conducted. One of the proposed capsules showed an average (SD) velocity in forward direction of 2.91 ± 0.99 mm/s and 2.23 ± 0.78 mm/s in the backward direction, which was 5.2 times faster than that obtained in previous research. The proposed model can predict locomotion of the capsule based on various exterior shapes of the capsule. PMID:22177218
NASA Astrophysics Data System (ADS)
Lv, Zhong; Chen, Huisu
2014-10-01
Autonomous healing of cracks using pre-embedded capsules containing healing agent is becoming a promising approach to restore the strength of damaged structures. In addition to the material properties, the size and volume fraction of capsules influence crack healing in the matrix. Understanding the crack and capsule interaction is critical in the development and design of structures made of self-healing materials. Assuming that the pre-embedded capsules are randomly dispersed we theoretically model flat ellipsoidal crack interaction with capsules and determine the probability of a crack intersecting the pre-embedded capsules i.e. the self-healing probability. We also develop a probabilistic model of a crack simultaneously meeting with capsules and catalyst carriers in two-component self-healing system matrix. Using a risk-based healing approach, we determine the volume fraction and size of the pre-embedded capsules that are required to achieve a certain self-healing probability. To understand the effect of the shape of the capsules on self-healing we theoretically modeled crack interaction with spherical and cylindrical capsules. We compared the results of our theoretical model with Monte-Carlo simulations of crack interaction with capsules. The formulae presented in this paper will provide guidelines for engineers working with self-healing structures in material selection and sustenance.
Radiation hydrodynamic effects in two beryllium plates with an idealized aluminum joint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belkov, S.A.; Mkhitarian, L.S.; Vinokurov, O.A.
A beryllium capsule formed from two hemispherical shells with a thin bond is one possible ignition target for the National Ignition Facility [J. A. Paisner {ital et al.}, Laser Focus World {bold 30}, 75 (1994)] Nonuniformities in density, opacity, and interface position at the joint between these hemishells will initiate two-dimensional (2-D) perturbations of the shock wave and material behind the shock as the shock passes through the shell perpendicular to the joint width. Rarefaction of material flow behind the shock front can cause the interface between the shell and joint material to oscillate in position. The amplitude of thesemore » oscillations may be comparable to the joint width. The evolution of these perturbations is studied by numerically simulating shock passage through flat beryllium plates containing aluminum joints. Using the MIMOSA-ND code [D. Sofronov {ital et al.}, Vopr. At. Nauki Tekh., Ser: Mat. modelirovanie fizicheskih processov {bold 2}, 3 (1990)] two different cases are calculated{emdash}a wide (10 {mu}m) and a narrow (1 {mu}m) joint of aluminum between two 150 {mu}m long semiinfinite beryllium plates. Both cases showed good agreement with an analytic representation of the oscillation behavior. For the narrow joint, a special technique allows the calculation of mixing between the joint and surrounding material caused by the Kelvin{endash}Helmholtz instability. {copyright} {ital 1999 American Institute of Physics.}« less
Vieira, Diego Henrique Mirandola Dias; Alama-Bermejo, Gema; Bartholomew, Jerri Lee; Abdallah, Vanessa Doro; de Azevedo, Rodney Kozlowiski
2017-12-01
Plasmodia containing myxospores belonging to the genus Myxobolus Bütschli, 1882 were found in the ovaries and liver of Salminus hilarii. Despite its economic value, this fish host has no previous reports of myxozoan infections. Herein, we describe Myxobolus batalhensis n. sp. using morphological and ultrastructural data, as well as histological and SSU rDNA molecular data. The mature myxospores were elongated, measuring in average 15.2 ± 0.8 μm in length, 8.4 ± 0.4 μm in width, and 5.1 ± 0.2 μm in thickness. Polar capsules were elongated and measured 5.3 ± 0.3 μm in length and 2.8 ± 0.3 μm in width. Polar filaments had 6-9 coils. Histopathological analysis showed coagulation necrosis associated with cell lysis as a response of the host cell to the parasite in the ovaries. No inflammatory reaction was observed in the liver, although the presence of the plasmodia caused changes in tissue structure. The phylogenetic analysis of South American myxobolid species showed M. batalhensis n. sp. as sister species of Myxobolus aureus. This is the first report of a myxozoan species parasitizing S. hilarii and the first myxozoan species described in the Batalha river.
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
Seat and seatbelt accommodation in fire apparatus: Anthropometric aspects
Hsiao, Hongwei; Whitestone, Jennifer; Wilbur, Michael; Lackore, J. Roger; Routley, J. Gordon
2015-01-01
This study developed anthropometric information on U.S. firefighters to guide fire-apparatus seat and seatbelt designs and future standards development. A stratified sample of 863 male and 88 female firefighters across the U.S. participated in the study. The study results suggested 498 mm in width, 404 mm in depth, and 365–476 mm in height for seat pans; 429–522 mm in width and 542 mm in height for seat back; 871 mm in height for head support; a seat space of 733 mm at shoulder and 678 mm at hip; and a knee/leg clearance of 909 mm in fire truck cab. Also, 1520 mm of lap belt web effective length and 2828 mm of lap-and-shoulder belt web effective length were suggested. These data for firetruck seats and seatbelts provide a foundation for fire apparatus manufacturers and standards committees to improve firefighter seat designs and seatbelt usage compliance. PMID:26154212
An analytic approach to optimize tidal turbine fields
NASA Astrophysics Data System (ADS)
Pelz, P.; Metzler, M.
2013-12-01
Motivated by global warming due to CO2-emission various technologies for harvesting of energy from renewable sources are developed. Hydrokinetic turbines get applied to surface watercourse or tidal flow to gain electrical energy. Since the available power for hydrokinetic turbines is proportional to the projected cross section area, fields of turbines are installed to scale shaft power. Each hydrokinetic turbine of a field can be considered as a disk actuator. In [1], the first author derives the optimal operation point for hydropower in an open-channel. The present paper concerns about a 0-dimensional model of a disk-actuator in an open-channel flow with bypass, as a special case of [1]. Based on the energy equation, the continuity equation and the momentum balance an analytical approach is made to calculate the coefficient of performance for hydrokinetic turbines with bypass flow as function of the turbine head and the ratio of turbine width to channel width.
Dual optical mechanical position tracker
NASA Astrophysics Data System (ADS)
Everett, S. L., Jr.
1985-06-01
This patent application describes an apparatus for retaining control of moving carriage impact dot matrix print heads when subjected to strong external forces such as shock and/or vibration. Position and direction of carriage movement is provided by a photo emitter-sensor assembly and a slotted timing wheel or disc having a plurality of equally spaced slots whose slot width is equal to the slot separation. The slot width is sufficient to frame a pair of side-by-side emitters which operate in conjunction with a pair of side-by-side sensors on the other side of the timing wheel. The order or sequence in which the sensors receive photo energy from their respective emitters indicates the direction of rotation of the timing wheel while simultaneous reception of photo energy by the side-by-side sensors provides an indication of valid rest position of the carriage drive motor.
Mironov, Sergey V; Palma, Ricardo L
2016-09-01
A new feather mite species, Trouessartia sechellarum sp. n. (Astigmata: Analgoidea: Trouessartiidae), is described from the Seychelles magpie-robin Copsychus sechellarum (Passeriformes: Muscicapidae), an endangered endemic passerine bird inhabiting the Seychelles Islands. The most clear features distinguishing this mite from the related species, T. microfolia Gaud, 1952, are as follows: in both sexes, setae c2 do not exceed 30 μm and are subequal in length to setae c3 and sRIII; in males, the hysteronotal shield is completely split into the prohysteronotal and lobar parts by a narrow groove, and the terminal lamellae are attenuate apically; in females, the median part of the hysteronotal shield bears numerous ovate lacunae, the terminal cleft width is approximately equal to the opisthosomal lobe width, and the collar of the spermathecal head is smooth.
The effect of glicerol and sorbitol plasticizers toward disintegration time of phyto-capsules
NASA Astrophysics Data System (ADS)
Pudjiastuti, Pratiwi; Hendradi, Esti; Wafiroh, Siti; Harsini, Muji; Darmokoesoemo, Handoko
2016-03-01
The aim of research is determining the effect of glycerol and sorbitol toward the disintegration time of phyto-capsules, originated capsules from plant polysaccharides. Phyto-capsules were made from polysaccharides and 0.5% (v/v) of glycerol and sorbitol of each. The seven capsules of each were determined the disintegration time using Erweka disintegrator. The mean of disintegration time of phyto-capsules without plasticizers, with glycerol and sorbitol were 25'30"; 45'15" and 35'30" respectively. The color and colorless gelatin capsules showed the mean of disintegration time 7'30" and 2'35" respectively.
Analytical model for effects of capsule shape on the healing efficiency in self-healing materials
Li, Songpeng; Chen, Huisu
2017-01-01
The fundamental requirement for the autonomous capsule-based self-healing process to work is that cracks need to reach the capsules and break them such that the healing agent can be released. Ignoring all other aspects, the amount of healing agents released into the crack is essential to obtain a good healing. Meanwhile, from the perspective of the capsule shapes, spherical or elongated capsules (hollow tubes/fibres) are the main morphologies used in capsule-based self-healing materials. The focus of this contribution is the description of the effects of capsule shape on the efficiency of healing agent released in capsule-based self-healing material within the framework of the theory of geometrical probability and integral geometry. Analytical models are developed to characterize the amount of healing agent released per crack area from capsules for an arbitrary crack intersecting with capsules of various shapes in a virtual capsule-based self-healing material. The average crack opening distance is chosen to be a key parameter in defining the healing potential of individual cracks in the models. Furthermore, the accuracy of the developed models was verified by comparison to the data from a published numerical simulation study. PMID:29095862
Johnstone, Nancy; Ward, Daniel A
2005-01-01
The objective of this retrospective study was to report the incidence of posterior capsule disruption during routine phacoemulsification and to document the postoperative outcomes and complications in eyes with posterior capsule disruption compared with eyes with intact posterior capsules. Records of 143 dogs (244 eyes) were reviewed. Data collected included whether the posterior capsule was disrupted, whether the disruption was planned or accidental, whether an intraocular lens was implanted, and visual outcome. Records were reviewed for postoperative complications. Intraocular lens implantation rates, complication rates, and visual outcomes were compared between intact and disrupted posterior capsule groups using Chi-square analyses. The posterior capsule was disrupted in 33/244 eyes (14%). Planned capsulotomies accounted for 36% of the disruptions. Intraocular lenses were implanted in 76% of eyes without a disruption of the posterior capsule and in 31% of eyes with a posterior capsule disruption. Intraocular lenses were more likely to be implanted in eyes with a planned disruption of the posterior capsule (7/12; 58%) than in eyes with an accidental disruption (3/20; 15%). There were no significant differences in postoperative complications or visual outcome between eyes with posterior capsule disruption and those without. The most significant complication of posterior capsule disruption during phacoemulsification is the inability to implant an intraocular lens. Intraocular lenses are more likely to be placed in eyes with intentional disruptions of the posterior capsule than those with accidental ruptures.
NASA Astrophysics Data System (ADS)
Andrade-Villagrán, P. V.; Baria, K. S.; Montory, J. A.; Pechenik, J. A.; Chaparro, O. R.
2018-01-01
Encapsulated embryos are generally thought to play an active role in escaping from egg capsules or egg masses. However, for species that brood their egg capsules, the factors controlling the timing of hatching are largely unclear, particularly the degree to which hatching is controlled by the embryos rather than by the mother, and the degree to which the hatching of one egg capsule influences the hatching of sister egg capsules within the same egg mass. We studied aspects of hatching using the direct-developing gastropod Crepipatella dilatata, which includes nurse eggs in its egg capsules and broods clusters of egg capsules for at least several weeks before metamorphosed juveniles are released. Isolated egg capsules were able to hatch successfully, in the absence of the mother. Moreover, the hatching of one capsule did not cause adjacent sister capsules to hatch. Hatched and un-hatched sister egg capsules from the same egg mass differed significantly in the number of metamorphosed juveniles, average shell size, offspring biomass (juveniles + veliger larvae), and the number of nurse eggs remaining per egg capsule. Differences in when egg capsules hatched within a single egg mass were not explained by differences in egg capsule age. Hatching occurred only after most nurse eggs had been ingested, most offspring had metamorphosed into juveniles, and juveniles had reached a mean shell length > 1.36 mm. Whether the mother has any role to play in coordinating the hatching process or juvenile release remains to be determined.
Veladiano, Irene A; Banzato, Tommaso; Bellini, Luca; Montani, Alessandro; Catania, Salvatore; Zotti, Alessandro
2016-12-01
OBJECTIVE To create an atlas of the normal CT anatomy of the head of blue-and-gold macaws (Ara ararauna), African grey parrots (Psittacus erithacus), and monk parakeets (Myiopsitta monachus). ANIMALS 3 blue-and-gold macaws, 5 African grey parrots, and 6 monk parakeets and cadavers of 4 adult blue-and-gold macaws, 4 adult African grey parrots, and 7 monk parakeets. PROCEDURES Contrast-enhanced CT imaging of the head of the live birds was performed with a 4-multidetector-row CT scanner. Cadaveric specimens were stored at -20°C until completely frozen, and each head was then sliced at 5-mm intervals to create reference cross sections. Frozen cross sections were cleaned with water and photographed on both sides. Anatomic structures within each head were identified with the aid of the available literature, labeled first on anatomic photographs, and then matched to and labeled on corresponding CT images. The best CT reconstruction filter, window width, and window level for obtaining diagnostic images of each structure were also identified. RESULTS Most of the clinically relevant structures of the head were identified in both the cross-sectional photographs and corresponding CT images. Optimal visibility of the bony structures was achieved via CT with a standard soft tissue filter and pulmonary window. The use of contrast medium allowed a thorough evaluation of the soft tissues. CONCLUSIONS AND CLINICAL RELEVANCE The labeled CT images and photographs of anatomic structures of the heads of common pet parrot species created in this study may be useful as an atlas to aid interpretation of images obtained with any imaging modality.
CHIMNEY FOR BOILING WATER REACTOR
Petrick, M.
1961-08-01
A boiling-water reactor is described which has vertical fuel-containing channels for forming steam from water. Risers above the channels increase the head of water radially outward, whereby water is moved upward through the channels with greater force. The risers are concentric and the radial width of the space between them is somewhat small. There is a relatively low rate of flow of water up through the radially outer fuel-containing channels, with which the space between the risers is in communication. (AE C)
Solid-State Sensor and Actuator Workshop Held in Hilton Head Island, South Carolina on 4-7 June 1990
1990-01-01
resonator was measured. It is shown in Figure 2. The text by Ferry gives very lucid discussions of the salient feature of the curves is that the width... features near 140 MHz. This is expected: the Synthesized SH-APM has displacement components on both faces of the quartz plate and, in this particular case...struc- [2 + F3 tural dimensions are highly desired features in micro- machined solid-state sensors, an understanding of damping WHERE caused by
Motion of an elastic capsule in a square microfluidic channel
Kuriakose, S.; Dimitrakopoulos, P.
2013-01-01
In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e. small, moderate and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to, and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross-section in the upstream portion of large capsules is non-axisymmetric (i.e. square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a−2 for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux−u~h~a−2 approach to the undisturbed average duct velocity and an additional pressure drop ΔP+ ~ a3/h ~ a5. By combining basic physical principles and geometric properties, we develop a theoretical analysis that explains the power laws we found for large capsules. PMID:21867212
Park, Jong Min; Park, So-Yeon; Wu, Hong-Gyun; Kim, Jung-In
2018-02-01
To investigate the changes in quality of the volumetric modulated arc therapy (VMAT) plans with couch-shift between arcs by half of a multi-leaf collimator (MLC) leaf width. A total of 22 patients with head-and-neck cancer were retrospectively selected. Since the smallest MLC leaf width was 5 mm in this study, the couch was shifted by 2.5 mm in the longitudinal-direction between arcs to increase the resolution of fluence map. A total of three types of VMAT plans were generated for each patient; the three types of plans were a two-full-arc plan without couch-shift (NS plan), a two-half-arc-pair plan with couch-shift (HAS plan), and a two-full-arc pair plan with couch-shift (FAS plan). Changes in the dose-volumetric parameters were investigated. The FAS plan showed the best plan quality for the target volumes and organs at risk compared to the NS and HAS plans. However, the magnitudes of differences among the three types of plans were minimal, and every plan was clinically acceptable. The average integral doses of the NS, HAS, and FAS plans were 160,549 ± 37,600 Gy-cc, 147,828 ± 33,343 Gy-cc, and 156,030 ± 36,263 Gy-cc, respectively. The average monitor unit of the NS, HAS, and FAS plans were 717 ± 120 MU, 648 ± 100 MU, and 763 ± 158 MU, respectively. The HAS plan was better than the others in terms of normal tissue sparing and plan efficiency. By shifting the couch by half of the MLC leaf width in the longitudinal direction between arcs, the VMAT plan quality could be improved. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Spheroidal and conical shapes of ferrofluid-filled capsules in magnetic fields
NASA Astrophysics Data System (ADS)
Wischnewski, Christian; Kierfeld, Jan
2018-04-01
We investigate the deformation of soft spherical elastic capsules filled with a ferrofluid in external uniform magnetic fields at fixed volume by a combination of numerical and analytical approaches. We develop a numerical iterative solution strategy based on nonlinear elastic shape equations to calculate the stretched capsule shape numerically and a coupled finite element and boundary element method to solve the corresponding magnetostatic problem and employ analytical linear response theory, approximative energy minimization, and slender-body theory. The observed deformation behavior is qualitatively similar to the deformation of ferrofluid droplets in uniform magnetic fields. Homogeneous magnetic fields elongate the capsule and a discontinuous shape transition from a spheroidal shape to a conical shape takes place at a critical field strength. We investigate how capsule elasticity modifies this hysteretic shape transition. We show that conical capsule shapes are possible but involve diverging stretch factors at the tips, which gives rise to rupture for real capsule materials. In a slender-body approximation we find that the critical susceptibility above which conical shapes occur for ferrofluid capsules is the same as for droplets. At small fields capsules remain spheroidal and we characterize the deformation of spheroidal capsules both analytically and numerically. Finally, we determine whether wrinkling of a spheroidal capsule occurs during elongation in a magnetic field and how it modifies the stretching behavior. We find the nontrivial dependence between the extent of the wrinkled region and capsule elongation. Our results can be helpful in quantitatively determining capsule or ferrofluid material properties from magnetic deformation experiments. All results also apply to elastic capsules filled with a dielectric liquid in an external uniform electric field.
Nifedipine capsules may provide a viable alternative to oral powders for paediatric patients.
Helin-Tanninen, M; Naaranlahti, T; Kontra, K; Savolainen, K
2007-02-01
To compare content uniformities between different sizes of extemporaneously compounded nifedipine oral powders and capsules, in order to find out if capsules could be used instead of oral powders as paediatric medications. Actual content and content uniformity of extemporaneously compounded 1-mg nifedipine oral powders and capsules were evaluated by a high performance liquid chromatographic assay. Capsules and powders were prepared by triturating 10-mg nifedipine tablets with different amounts of lactose or microcrystalline cellulose with a mortar and pestle using a standard geometric dilution technique. Oral powders were weighed individually and capsules were filled by a hand-operated capsule-filling machine. Four different sizes of powders (500, 300, 100 and 50 mg) and three different sizes of capsules (numbers 1, 3 and 4) were prepared. Ten oral powders and 10 capsules from each batch were randomly selected and individually assayed for nifedipine amount. The extemporaneously prepared nifedipine oral powders and capsules were within acceptable limits for content uniformity, as defined by the European Pharmacopoeia, but the results indicate that the loss of nifedipine during the preparation process may be considerable for both preparations. The concentration on nifedipine decreased while the total mass of the oral powder decreased. These results demonstrate that nifedipine oral powders can be replaced by capsules, whose contents are emptied for use, in paediatric medications. Compounding small capsules, such as size number 3 or 4, is acceptable when considering the average drug content. The total weight of the oral powder should be at least 300 mg. The preparation of nifedipine in all studied capsule sizes was safe with either lactose monohydrate or microcrystalline cellulose as excipients. Thus, emptied capsules seem to be a good choice for delivering a paediatric medication. The loss of nifedipine was considerable in oral powders with low total weight.
Internalization of Red Blood Cell-Mimicking Hydrogel Capsules with pH-Triggered Shape Responses
2015-01-01
We report on naturally inspired hydrogel capsules with pH-induced transitions from discoids to oblate ellipsoids and their interactions with cells. We integrate characteristics of erythrocytes such as discoidal shape, hollow structure, and elasticity with reversible pH-responsiveness of poly(methacrylic acid) (PMAA) to design a new type of drug delivery carrier to be potentially triggered by chemical stimuli in the tumor lesion. The capsules are fabricated from cross-linked PMAA multilayers using sacrificial discoid silicon templates. The degree of capsule shape transition is controlled by the pH-tuned volume change, which in turn is regulated by the capsule wall composition. The (PMAA)15 capsules undergo a dramatic 24-fold volume change, while a moderate 2.3-fold volume variation is observed for more rigid PMAA–(poly(N-vinylpyrrolidone) (PMAA–PVPON)5 capsules when solution pH is varied between 7.4 and 4. Despite that both types of capsules exhibit discoid-to-oblate ellipsoid transitions, a 3-fold greater swelling in radial dimensions is found for one-component systems due to a greater degree of the circular face bulging. We also show that (PMAA–PVPON)5 discoidal capsules interact differently with J774A.1 macrophages, HMVEC endothelial cells, and 4T1 breast cancer cells. The discoidal capsules show 60% lower internalization as compared to spherical capsules. Finally, hydrogel capsules demonstrate a 2-fold decrease in size upon internalization. These capsules represent a unique example of elastic hydrogel discoids capable of pH-induced drastic and reversible variations in aspect ratios. Considering the RBC-mimicking shape, their dimensions, and their capability to undergo pH-triggered intracellular responses, the hydrogel capsules demonstrate considerable potential as novel carriers in shape-regulated transport and cellular uptake. PMID:24848786
Optimum Design of a Ceramic Tensile Creep Specimen Using a Finite Element Method
Wang, Z.; Chiang, C. K.; Chuang, T.-J.
1997-01-01
An optimization procedure for designing a ceramic tensile creep specimen to minimize stress concentration is carried out using a finite element method. The effect of pin loading and the specimen geometry are considered in the stress distribution calculations. A growing contact zone between the pin and the specimen has been incorporated into the problem solution scheme as the load is increased to its full value. The optimization procedures are performed for the specimen, and all design variables including pinhole location and pinhole diameter, head width, neck radius, and gauge length are determined based on a set of constraints imposed on the problem. In addition, for the purpose of assessing the possibility of delayed failure outside the gage section, power-law creep in the tensile specimen is considered in the analysis. Using a particular grade of advanced ceramics as an example, it is found that if the specimen is not designed properly, significant creep deformation and stress redistribution may occur in the head of the specimen resulting in undesirable (delayed) head failure of the specimen during the creep test. PMID:27805126
Effect of sperm concentration in an ejaculate on morphometric traits of spermatozoa in Duroc boars.
Kondracki, S; Wysokińska, A; Iwanina, M; Banaszewska, D; Sitarz, D
2011-01-01
The experimental material consisted of 75 ejaculates collected form 8 Duroc boars. The ejaculates were divided into three groups according to sperm concentration in an ejaculate. An ejaculate was obtained from each boar monthly and it was used to make microscopic preparations to examine spermatozoa morphology. In each preparation morphometric measurements were taken of fifteen randomly selected spermatozoa characterized by normal morphology. The following measurements of spermatozoa were taken: length and width of the spermatozoa head, head area, length of the flagellum, perimeter of the spermatozoon head and total spermatozoon length. The results were used to calculate indicators of spermatozoa morphology. Moreover, assessments were made of frequency of morphological defects to isolate spermatozoa with primary and secondary abnormalities following the Blom classification system. It was found that the concentration of spermatozoa in the ejaculate influenced the morphometric characteristics of spermatozoa. Ejaculates with low sperm concentrations are characterized by larger spermatozoa as compared to ejaculates with high sperm concentrations. However, sperm concentration in the ejaculate does not much influence the shape of spermatozoa.
Effect of Fin Passage Length on Optimization of Cylinder Head Cooling Fins
NASA Technical Reports Server (NTRS)
Siegel, R.; Graham, R. W.
1977-01-01
The heat transfer performance of baffled cooling fins on cylinder heads of small, air-cooled, general-aviation aircraft engines was analyzed to determine the potential for improving cooling fin design. Flow baffles were assumed to be installed tightly against the fin end edges, an ideal baffle configuration for guiding all flow between the fins. A rectangular flow passage is thereby formed between each set of two adjacent fins, the fin base surface, and the baffle. These passages extend around each side of the cylinder head, and the cooling air absorbs heat as it flows within them. For each flow passage length, the analysis was concerned with optimizing fin spacing and thickness to achieve the best heat transfer for each fin width. Previous literature has been concerned mainly with maximizing the local fin conductance and has not considered the heating of the gas in the flow direction, which leads to higher wall temperatures at the fin passage exits. If the fins are close together, there is a large surface area, but the airflow is restricted.
Isberg, S R; Thomson, P C; Nicholas, F W; Barker, S G; Moran, C
2005-12-01
Crocodile morphometric (head, snout-vent and total length) measurements were recorded at three stages during the production chain: hatching, inventory [average age (+/-SE) is 265.1 +/- 0.4 days] and slaughter (average age is 1037.8 +/- 0.4 days). Crocodile skins are used for the manufacture of exclusive leather products, with the most common-sized skin sold having 35-45 cm in belly width. One of the breeding objectives for inclusion into a multitrait genetic improvement programme for saltwater crocodiles is the time taken for a juvenile to reach this size or age at slaughter. A multivariate restricted maximum likelihood analysis provided (co)variance components for estimating the first published genetic parameter estimates for these traits. Heritability (+/-SE) estimates for the traits hatchling snout-vent length, inventory head length and age at slaughter were 0.60 (0.15), 0.59 (0.12) and 0.40 (0.10) respectively. There were strong negative genetic (-0.81 +/- 0.08) and phenotypic (-0.82 +/- 0.02) correlations between age at slaughter and inventory head length.
Experimental measurement on movement of spiral-type capsule endoscope
Yang, Wanan; Dai, Houde; He, Yong; Qin, Fengqing
2016-01-01
Wireless capsule endoscope achieved great success, however, the maneuvering of wireless capsule endoscope is challenging at present. A magnetic driving instrument, including two bar magnets, a stepper motor, a motor driver, a motor controller, and a power supplier, was developed to generate rotational magnetic fields. Permanent magnet ring, magnetized as S and N poles radially and mounted spiral structure on the surface, acted as a capsule. The maximum torque passing to the capsule, rotational synchronization of capsule and motor, and the translational speed of capsule, were measured in ex vivo porcine large intestine. The experimental results illustrate that the rotational movement of the spiral-type capsule in the intestine is feasible and the cost of the magnetic driving equipment is low. As a result, the solution is promising in the future controllability. PMID:26848279
Experimental measurement on movement of spiral-type capsule endoscope.
Yang, Wanan; Dai, Houde; He, Yong; Qin, Fengqing
2016-01-01
Wireless capsule endoscope achieved great success, however, the maneuvering of wireless capsule endoscope is challenging at present. A magnetic driving instrument, including two bar magnets, a stepper motor, a motor driver, a motor controller, and a power supplier, was developed to generate rotational magnetic fields. Permanent magnet ring, magnetized as S and N poles radially and mounted spiral structure on the surface, acted as a capsule. The maximum torque passing to the capsule, rotational synchronization of capsule and motor, and the translational speed of capsule, were measured in ex vivo porcine large intestine. The experimental results illustrate that the rotational movement of the spiral-type capsule in the intestine is feasible and the cost of the magnetic driving equipment is low. As a result, the solution is promising in the future controllability.
NASA Astrophysics Data System (ADS)
Arumnika, N.; Kuswanto, H.
2018-04-01
This study aimed to determine the effect of curvature configuration to sensitivities and linearities of Polymer Optical Fiber (POF) water level sensor. POF type SH-4001-1.3 has been used in this study. The jacket of POF of 20 cm was removed. Transparent piped inserted by alcohol gel has been used to replace the jacket. This is head of a sensor. The head of a sensor is curved with variations of the specified path length, peel length, the width of curvature, the height of curvature and waveform. Configuration A (20 cm, 34 cm, 6 cm, 2 cm, 1 wave), configuration B (20 cm, 34 cm, 8 cm, 2 cm, 1 wave), configuration C (20 cm, 34 cm, 9 cm, 2 cm, ½ wave), configuration D (20 cm, 34 cm, 10 cm, 2 cm, ½ wave). The head of a sensor inserted into the water tank. The light source inserted to one end POF is a He-Ne laser light with a power of 5 mW and a wavelength of 632.8 nm. Power output at the other end received by the Optical Power Meter (OPM). The curvature configuration the head sensor of POF affects the output. Configuration A has good sensitivity, however good linearity given by configuration.
Wegener, Veronika; Jorysz, Gabriele; Arnoldi, Andreas; Utzschneider, Sandra; Wegener, Bernd; Jansson, Volkmar; Heimkes, Bernhard
2017-03-01
Evaluation of hip joint space width during child growth is important to aid in the early diagnosis of hip pathology in children. We established reference values for hip joint space and femoral head size for each age. Hip joint space development during growth was retrospectively investigated medial and cranial in 1350 hip joints of children using standard anteroposterior supine plain pelvic radiographs. Maximum capital femoral epiphysis diameter and femoral radii were further more investigated. Hip joint space values show a slow decline during growth. Joint space was statistically significantly (p < 0.006) larger in boys than girls. Our hip joint space measurements on supine subjects seem slightly larger than those reported by Hughes on standing subjects. Evaluation of the femoral head diameter and the radii showed a size curve quite parallel to the known body growth charts. Radii medial and perpendicular to the physis are not statistically significantly different. We recommend to compare measurements of hip joint space at two locations to age dependent charts using the same imaging technique. During growth, a divergence in femoral head size from the expected values or loss of the spherical shape should raise the question of hip disorder. Clin. Anat. 30:267-275, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Kurunmäki, H; Toivonen, J; Lähteenmäki, P; Luukkainen, T
1985-03-01
One Silastic capsule of 15 mm, 20 mm or 30 mm length was inserted subcutaneously into the ventral aspect of the left forearm or upper arm of 28 healthy women during menstrual bleeding or not later than on the seventh day of the menstrual cycle. A new capsule of the same length was inserted after six months and both capsules were removed twelve months after the first insertion. Side-effects, including changes in body weight, blood pressure, menstrual bleeding and liver function test results, were registered. Blood samples were taken from selected subjects twice a week during the 1st, 2nd, 3rd, 6th, 7th and 12th month of use. Plasma concentrations of ST-1435 were measured by radioimmunoassay and the effects of treatment on pituitary and ovarian function were determined by assaying plasma concentrations of LH, FSH, estradiol and progesterone. There were no differences in hormonal side-effects between subjects who had a 30 mm capsule or subjects who had 20 mm or 15 mm capsules, but subjects who had 20 or 15 mm capsules had significantly longer bleeding or spotting periods in comparison with subjects who had a 30 mm capsule. There were no changes in blood pressure, body weight or liver function test results in comparison with pre-insertion values. The plasma level of ST-1435 was not significantly higher during the use of 30 mm capsules than during the use of 20 or 15 mm capsules. During the use of the shorter ST-1435 capsules, plasma estradiol elevation and slightly suppressed FSH were seen, while the use of longer capsules resulted in a slight suppression of LH. Progesterone concentrations during monitored cycles indicated anovulation. No pregnancies occurred during the study period of one year. The continuation rate at one year was 71% in the 30 mm capsule group and 57% in the 20 and 15 mm capsule groups taken together.
Demura, Shinichi; Sato, Susumu; Nakada, Masakatsu; Minami, Masaki; Kitabayashi, Tamotsu
2003-07-01
This study compared the accuracy of body density (Db) estimation methods using hydrostatic weighing without complete head submersion (HW(withoutHS)) of Donnelly et al. (1988) and Donnelly and Sintek (1984) as referenced to Goldman and Buskirk's approach (1961). Donnelly et al.'s method estimates Db from a regression equation using HW(withoutHS), moreover, Donnelly and Sintek's method estimates it from HW(withoutHS) and head anthropometric variables. Fifteen Japanese males (173.8+/-4.5 cm, 63.6+/-5.4 kg, 21.2+/-2.8 years) and fifteen females (161.4+/-5.4 cm, 53.8+/-4.8 kg, 21.0+/-1.4 years) participated in this study. All the subjects were measured for head length, width and HWs under the two conditions of with and without head submersion. In order to examine the consistency of estimation values of Db, the correlation coefficients between the estimation values and the reference (Goldman and Buskirk, 1961) were calculated. The standard errors of estimation (SEE) were calculated by regression analysis using a reference value as a dependent variable and estimation values as independent variables. In addition, the systematic errors of two estimation methods were investigated by the Bland-Altman technique (Bland and Altman, 1986). In the estimation, Donnelly and Sintek's equation showed a high relationship with the reference (r=0.960, p<0.01), but had more differences from the reference compared with Donnelly et al.'s equation. Further studies are needed to develop new prediction equations for Japanese considering sex and individual differences in head anthropometry.
Safety of capsule endoscopy using human body communication in patients with cardiac devices.
Chung, Joo Won; Hwang, Hye Jin; Chung, Moon Jae; Park, Jeong Youp; Pak, Hui-Nam; Song, Si Young
2012-06-01
The MiroCam (IntroMedic, Ltd., Seoul, Korea) is a small-bowel capsule endoscope that uses human body communication to transmit data. The potential interactions between cardiac devices and the capsule endoscope are causes for concern, but no data are available for this matter. This clinical study was designed to evaluate the potential influence of the MiroCam capsules on cardiac devices. Patients with cardiac pacemakers or implantable cardiac defibrillators referred for evaluation of small bowel disease were prospectively enrolled in this study. Before capsule endoscopy, a cardiologist checked baseline electrocardiograms and functions of the cardiac devices. Cardiac rhythms were continuously monitored by 24-h telemetry during capsule endoscopy in the hospital. After completion of procedures, functions of the cardiac devices were checked again for interference. Images from the capsule endoscopy were reviewed and analyzed for technical problems. Six patients, three with pacemakers and three with implantable cardiac defibrillators, were included in the study. We identified no disturbances in the cardiac devices and no arrhythmias detected on telemetry monitoring during capsule endoscopy. No significant changes in the programmed parameters of the cardiac devices were noted after capsule endoscopy. There were no imaging disturbances from the cardiac devices on capsule endoscopy. Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.
Multiple internalization pathways of polyelectrolyte multilayer capsules into mammalian cells.
Kastl, Lena; Sasse, Daniel; Wulf, Verena; Hartmann, Raimo; Mircheski, Josif; Ranke, Christiane; Carregal-Romero, Susana; Martínez-López, José Antonio; Fernández-Chacón, Rafael; Parak, Wolfgang J; Elsasser, Hans-Peter; Rivera Gil, Pilar
2013-08-27
Polyelectrolyte multilayer (PEM) capsules are carrier vehicles with great potential for biomedical applications. With the future aim of designing biocompatible, effective therapeutic delivery systems (e.g., for cancer), the pathway of internalization (uptake and fate) of PEM capsules was investigated. In particular the following experiments were performed: (i) the study of capsule co-localization with established endocytic markers, (ii) switching-off endocytotic pathways with pharmaceutical/chemical inhibitors, and (iii) characterization and quantification of capsule uptake with confocal and electron microscopy. As result, capsules co-localized with lipid rafts and with phagolysosomes, but not with other endocytic vesicles. Chemical interference of endocytosis with chemical blockers indicated that PEM capsules enter the investigated cell lines through a mechanism slightly sensitive to electrostatic interactions, independent of clathrin and caveolae, and strongly dependent on cholesterol-rich domains and organelle acidification. Microscopic characterization of cells during capsule uptake showed the formation of phagocytic cups (vesicles) to engulf the capsules, an increased number of mitochondria, and a final localization in the perinuclear cytoplasma. Combining all these indicators we conclude that PEM capsule internalization in general occurs as a combination of different sequential mechanisms. Initially, an adsorptive mechanism due to strong electrostatic interactions governs the stabilization of the capsules at the cell surface. Membrane ruffling and filopodia extensions are responsible for capsule engulfing through the formation of a phagocytic cup. Co-localization with lipid raft domains activates the cell to initiate a lipid-raft-mediated macropinocytosis. Internalization vesicles are very acidic and co-localize only with phagolysosome markers, excluding caveolin-mediated pathways and indicating that upon phagocytosis the capsules are sorted to heterophagolysosomes.
Gubler, C; Fox, M; Hengstler, P; Abraham, D; Eigenmann, F; Bauerfeind, P
2007-12-01
Capsule endoscopy is widely used for diagnosis of small-bowel disease; however, the impact of capsule endoscopy on clinical management remains uncertain. We conducted a prospective study of the impact capsule endoscopy on clinical management decisions in 128 patients with suspected small-bowel pathology. Prior to performing each procedure the gastroenterologist predicted the findings of capsule endoscopy and further management based on the clinical history and previous investigations. This prediction was compared with the actual results of capsule endoscopy and the following investigative and therapeutic management. The actual findings of capsule endoscopy and the further management were consistent with clinical prediction in 93/128 patients (73 %) and, irrespective of capsule endoscopy findings, no further procedures were required in 80 % of these patients. In 13 patients (10 %), gastric or colonic pathology was discovered that had not been detected on prior gastroscopy or colonoscopy. Thus, capsule endoscopy findings in the small bowel changed clinical management in 22 patients (17 %). In 4 patients, positive findings on capsule endoscopy that had not been predicted by the examiner prompted referral for abdominal surgery. Conversely, planned surgery was canceled in four other patients. In this series of patients referred for capsule endoscopy, small-bowel findings and appropriate clinical management were predicted on clinical grounds alone in approximately three-quarters of patients. Repetition of standard upper and lower endoscopy may be useful in many patients prior to small-bowel imaging. Referral for capsule endoscopy should take into account whether the findings will impact on clinical management; however, capsule endoscopy is mandatory in patients in whom surgery for small-bowel bleeding is intended.
Sundaramurthy, Anandhakumar; Sundramoorthy, Ashok K
2018-02-01
In recent years, the design of stimuli-responsive hollow polymeric capsules is of tremendous interest for the scientific community because of the broad application of these capsules in the biomedical field. The use of weak polyelectrolytes as layer components for capsule fabrication is especially interesting as it results in hollow capsules that show unique release characteristics under physiological conditions. In this work, a methodology to prepare sub-micron sized alginate doped calcium carbonate (CaCO 3 ) particles through controlled precipitation in the presence of alginate is reported. Hollow capsules obtained by Layer-by-Layer (LbL) assembly of poly(allylamine hydrochloride) (PAH) and poly(methacrylic acid) (PMA) are showing an interconnected alginate matrix in the interior of the capsules. Investigations showed that the presence of alginate matrix enhances the encapsulation of cationic molecules (e.g. doxorubicin hydrochloride) manifold by charge controlled attraction mechanism. Capsule permeability investigated by confocal laser scanning microscopy revealed that the transformation from an open state to closed state is accompanied by an intermediate state where capsules are neither open nor closed. Furthermore, time dependent study indicated that the encapsulation process is linear as a function of time. The cell viability experiments demonstrated excellent biocompatibility of hollow capsules with mouse embryonic fibroblast cells. Anticancer investigations showed that DOX loaded capsules have significant anti-proliferative characteristics against HeLa cells. Such capsules have high potential for use as drug carrier for cationic drugs in cancer therapy. Copyright © 2017 Elsevier B.V. All rights reserved.
Basic ammonothermal GaN growth in molybdenum capsules
NASA Astrophysics Data System (ADS)
Pimputkar, S.; Speck, J. S.; Nakamura, S.
2016-12-01
Single crystal, bulk gallium nitride (GaN) crystals were grown using the basic ammonothermal method in a high purity growth environment created using a non-hermetically sealed molybdenum (Mo) capsule and compared to growths performed in a similarly designed silver (Ag) capsule and capsule-free René 41 autoclave. Secondary ion mass spectrometry (SIMS) analysis revealed transition metal free (<1×1017 cm-3) GaN crystals. Anomalously low oxygen concentrations ((2-6)×1018 cm-3) were measured in a {0001} seeded crystal boule grown using a Mo capsule, despite higher source material oxygen concentrations ((1-5)×1019 cm-3) suggesting that molybdenum (or molybdenum nitrides) may act to getter oxygen under certain conditions. Total system pressure profiles from growth runs in a Mo capsule system were comparable to those without a capsule, with pressures peaking within 2 days and slowly decaying due to hydrogen diffusional losses. Measured Mo capsule GaN growth rates were comparable to un-optimized growth rates in capsule-free systems and appreciably slower than in Ag-capsule systems. Crystal quality replicated that of the GaN seed crystals for all capsule conditions, with high quality growth occurring on the (0001) Ga-face. Optical absorption and impurity concentration characterization suggests reduced concentrations of hydrogenated gallium vacancies (VGa-Hx).
Colonius, Hans; Diederich, Adele
2011-07-01
The concept of a "time window of integration" holds that information from different sensory modalities must not be perceived too far apart in time in order to be integrated into a multisensory perceptual event. Empirical estimates of window width differ widely, however, ranging from 40 to 600 ms depending on context and experimental paradigm. Searching for theoretical derivation of window width, Colonius and Diederich (Front Integr Neurosci 2010) developed a decision-theoretic framework using a decision rule that is based on the prior probability of a common source, the likelihood of temporal disparities between the unimodal signals, and the payoff for making right or wrong decisions. Here, this framework is extended to the focused attention task where subjects are asked to respond to signals from a target modality only. Evoking the framework of the time-window-of-integration (TWIN) model, an explicit expression for optimal window width is obtained. The approach is probed on two published focused attention studies. The first is a saccadic reaction time study assessing the efficiency with which multisensory integration varies as a function of aging. Although the window widths for young and older adults differ by nearly 200 ms, presumably due to their different peripheral processing speeds, neither of them deviates significantly from the optimal values. In the second study, head saccadic reactions times to a perfectly aligned audiovisual stimulus pair had been shown to depend on the prior probability of spatial alignment. Intriguingly, they reflected the magnitude of the time-window widths predicted by our decision-theoretic framework, i.e., a larger time window is associated with a higher prior probability.
Gwosch, K; Hartmann, B; Jakubek, J; Granja, C; Soukup, P; Jäkel, O; Martišíková, M
2013-06-07
Radiotherapy with narrow scanned carbon ion beams enables a highly accurate treatment of tumours while sparing the surrounding healthy tissue. Changes in the patient's geometry can alter the actual ion range in tissue and result in unfavourable changes in the dose distribution. Consequently, it is desired to verify the actual beam delivery within the patient. Real-time and non-invasive measurement methods are preferable. Currently, the only technically feasible method to monitor the delivered dose distribution within the patient is based on tissue activation measurements by means of positron emission tomography (PET). An alternative monitoring method based on tracking of prompt secondary ions leaving a patient irradiated with carbon ion beams has been previously suggested. It is expected to help in overcoming the limitations of the PET-based technique like physiological washout of the beam induced activity, low signal and to allow for real-time measurements. In this paper, measurements of secondary charged particle tracks around a head-sized homogeneous PMMA phantom irradiated with pencil-like carbon ion beams are presented. The investigated energies and beam widths are within the therapeutically used range. The aim of the study is to deduce properties of the primary beam from the distribution of the secondary charged particles. Experiments were performed at the Heidelberg Ion Beam Therapy Center, Germany. The directions of secondary charged particles emerging from the PMMA phantom were measured using an arrangement of two parallel pixelated silicon detectors (Timepix). The distribution of the registered particle tracks was analysed to deduce its dependence on clinically important beam parameters: beam range, width and position. Distinct dependencies of the secondary particle tracks on the properties of the primary carbon ion beam were observed. In the particular experimental set-up used, beam range differences of 1.3 mm were detectable. In addition, variations in the beam width could be measured with a precision of 0.9 mm. Furthermore, shifts of the lateral beam position could be monitored with a sub-millimetre precision. The presented investigations demonstrate experimentally that the non-invasive measurement and analysis of secondary ion distributions around head-sized homogeneous objects provide information on the actual beam delivery. Beam range, width and position could be monitored with a precision attractive for therapeutic situations.
Gettering capsule for removing oxygen from liquid lithium systems
NASA Technical Reports Server (NTRS)
Tower, L. K.; Breitwieser, R.
1973-01-01
Capsule consisting of tantalum shell lined with tantalum screen and partially filled with lithium and pieces of yttrium is immersed in hot lithium stream. Oxygen is removed from stream by being absorbed by gettering capsule. Oxygen passes through capsule wall and into lithium inside capsule where it reacts with yttrium to form Y2O3.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-09
... withdrawing approval of a new drug application (NDA) for DURACT (bromfenac sodium) Capsules, held by Wyeth... voluntarily withdrew DURACT (bromfenac sodium) Capsules from the market. DURACT (bromfenac sodium) Capsules, a... sodium) Capsules, under Sec. 314.150(d) (21 CFR 314.150(d)). In that letter, Wyeth also waived its...
Capsule Shimming Developments for National Ignition Facility (NIF) Hohlraum Asymmetry Experiments
Rice, Neal G.; Vu, M.; Kong, C.; ...
2017-12-20
Capsule drive in National Ignition Facility (NIF) indirect drive implosions is generated by x-ray illumination from cylindrical hohlraums. The cylindrical hohlraum geometry is axially symmetric but not spherically symmetric causing capsule-fuel drive asymmetries. We hypothesize that fabricating capsules asymmetric in wall thickness (shimmed) may compensate for drive asymmetries and improve implosion symmetry. Simulations suggest that for high compression implosions Legendre mode P 4 hohlraum flux asymmetries are the most detrimental to implosion performance. General Atomics has developed a diamond turning method to form a GDP capsule outer surface to a Legendre mode P 4 profile. The P 4 shape requiresmore » full capsule surface coverage. Thus, in order to avoid tool-lathe interference flipping the capsule part way through the machining process is required. This flipping process risks misalignment of the capsule causing a vertical step feature on the capsule surface. Recent trials have proven this step feature height can be minimized to ~0.25 µm.« less
NASA Astrophysics Data System (ADS)
Tuozzolo, S.; Durand, M. T.; Pavelsky, T.; Pentecost, J.
2015-12-01
The upcoming Surface Water and Ocean Topography (SWOT) satellite will provide measurements of river width and water surface elevation and slope along continuous swaths of world rivers. Understanding water surface slope and width dynamics in river reaches is important for both developing and validating discharge algorithms to be used on future SWOT data. We collected water surface elevation and river width data along a 6.5km stretch of the Olentangy River in Columbus, Ohio from October to December 2014. Continuous measurements of water surface height were supplemented with periodical river width measurements at twenty sites along the study reach. The water surface slope of the entire reach ranged from during 41.58 cm/km at baseflow to 45.31 cm/km after a storm event. The study reach was also broken into sub-reaches roughly 1km in length to study smaller scale slope dynamics. The furthest upstream sub-reaches are characterized by free-flowing riffle-pool sequences, while the furthest downstream sub-reaches were directly affected by two low-head dams. In the sub-reaches immediately upstream of each dam, baseflow slope is as low as 2 cm/km, while the furthest upstream free-flowing sub-reach has a baseflow slope of 100 cm/km. During high flow events the backwater effect of the dams was observed to propagate upstream: sub-reaches impounded by the dams had increased water surface slopes, while free flowing sub-reaches had decreased water surface slopes. During the largest observed flow event, a stage change of 0.40 m affected sub-reach slopes by as much as 30 cm/km. Further analysis will examine height-width relationships within the study reach and relate cross-sectional flow area to river stage. These relationships can be used in conjunction with slope data to estimate discharge using a modified Manning's equation, and are a core component of discharge algorithms being developed for the SWOT mission.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jubin, Robert Thomas; Bruffey, Stephanie H.
Legacy samples composed of 85Kr encapsulated in solid zeolite 5A material and five small metal tubes containing a mixture of the zeolite combined with a glass matrix resulting from hot isostatic pressing have been preserved. The samples were a result of krypton R&D encapsulation efforts in the late 1970s performed at the Idaho Chemical Processing Plant. These samples were shipped to Oak Ridge National Laboratory (ORNL) in mid-FY 2014. Upon receipt the outer shipping package was opened, and the inner package, removed and placed in a radiological hood. The individual capsules were double bagged as they were removed from themore » inner shipping pig and placed into individual glass sample bottles for further analysis. The five capsules were then x-ray imaged. Capsules 1 and 4 appear intact and to contain an amorphous mass within the capsules. Capsule 2 clearly shows the saw marks on the capsule and a quantity of loose pellet or bead-like material remaining in the capsule. Capsule 3 shows similar bead-like material within the intact capsule. Capsule 5 had been opened at an undetermined time in the past. The end of this capsule appears to have been cut off, and there are additional saw marks on the side of the capsule. X-ray tomography allowed the capsules to be viewed along the three axes. Of most interest was determining whether there was any residual material in the closed end of Capsule 5. The images confirmed the presence of residual material within this capsule. The material appears to be compacted but still retains some of the bead-like morphology. Based on the nondestructive analysis (NDA) results, a proposed path forward was formulated to advance this effort toward the original goals of understanding the effects of extended storage on the waste form and package. Based on the initial NDA and the fact that there are at least two breached samples, it was proposed that exploratory tests be conducted with the breached specimens before opening the three intact capsules. Portions of these would be analyzed to determine the fraction of krypton/xenon remaining in the matrix and the amount of rubidium remaining in the matrix. The inner surface of the breached capsules would be examined for corrosion. The materials contained in Capsules 2 and 5 have been examined. There appears to be a relatively uniform distribution of Kr and Rb throughout the pellets examined. The chemical composition of the pellets appears to be consistent with 5A molecular sieves. The material contained within Capsule 5 showed ~1 at. % lead. The origin of the Pb is currently indeterminate. X-ray diffraction analysis shows a significant shift from the 5A structure, most likely due to the Kr encapsulation / sintering process that occurred when the samples were made. The capsule walls were also examined and showed extensive corrosion throughout. Elemental mapping of the capsule material appeared consistent with carbon steel, while the weld material appeared consistent with a stainless steel. The interior surface of the capsule appeared to have a layer of material containing Al, Si, and Ca similar to the 5A molecular sieve. Analysis for Rb within the corrosion sites was inconclusive.« less
Yang, Hae Kyung; Ham, Dong-Sik; Park, Heon-Seok; Rhee, Marie; You, Young Hye; Kim, Min Jung; Shin, Juyoung; Kim, On-You; Khang, Gilson; Hong, Tae Ho; Kim, Ji-Won; Lee, Seung-Hwan; Cho, Jae-Hyoung; Yoon, Kun-Ho
2016-02-01
Clinical application of encapsulated islet transplantation is hindered by low biocompatibility of capsules leading to pericapsular fibrosis and decreased islet viability. To improve biocompatibility, we designed a novel chitosan-coated alginate capsules and compared them to uncoated alginate capsules. Alginate capsules were formed by crosslinking with BaCl2, then they were suspended in chitosan solution for 10 minutes at pH 4.5. Xenogeneic islet transplantation, using encapsulated porcine islets in 1,3-galactosyltransferase knockout mice, and allogeneic islet transplantation, using encapsulated canine islets in beagles, were performed without immunosuppressants. The chitosan-alginate capsules showed similar pore size, islet viability, and insulin secretory function compared to alginate capsules, in vitro. Xenogeneic transplantation of chitosan-alginate capsules demonstrated a trend toward superior graft survival (P = 0.07) with significantly less pericapsular fibrosis (cell adhesion score: 3.77 ± 0.41 vs 8.08 ± 0.05; P < 0.001) compared to that of alginate capsules up to 1 year after transplantation. Allogeneic transplantation of chitosan-alginate capsules normalized the blood glucose level up to 1 year with little evidence of pericapsular fibrotic overgrowth on graft explantation. The efficacy and biocompatibility of chitosan-alginate capsules were demonstrated in xenogeneic and allogeneic islet transplantations using small and large animal models of diabetes. This capsule might be a potential candidate applicable in the treatment of type 1 diabetes mellitus patients, and further studies in nonhuman primates are required.
Identification of a functional capsule locus in Streptococcus mitis.
Rukke, H V; Hegna, I K; Petersen, F C
2012-04-01
The polysaccharide capsule of Streptococcus pneumoniae is a hallmark for virulence in humans. In its close relative Streptococcus mitis, a common human commensal, analysis of the sequenced genomes of six strains revealed the presence of a putative capsule locus in four of them. We constructed an isogenic S. mitis mutant from the type strain that lacked the 19 open reading frames in the capsule locus (Δcps mutant), using a deletion strategy similar to previous capsule functional studies in S. pneumoniae. Transmission electron microscopy and atomic force microscopy revealed a capsule-like structure in the S. mitis type strain that was absent or reduced in the Δcps mutant. Since S. mitis are predominant oral colonizers of tooth surfaces, we addressed the relevance of the capsule locus for the S. mitis overall surface properties, autoaggregation and biofilm formation. The capsule deletion resulted in a mutant with approximately two-fold increase in hydrophobicity. Binding to the Stains-all cationic dye was reduced by 40%, suggesting a reduction in the overall negative surface charge of the mutant. The mutant exhibited also increased autoaggregation in coaggregation buffer, and up to six-fold increase in biofilm levels. The results suggested that the capsule locus is associated with production of a capsule-like structure in S. mitis and indicated that the S. mitis capsule-like structure may confer surface attributes similar to those associated with the capsule in S. pneumoniae. © 2011 John Wiley & Sons A/S.
Microsurgical and Tractographic Anatomy of the Supplementary Motor Area Complex in Humans.
Bozkurt, Baran; Yagmurlu, Kaan; Middlebrooks, Erik H; Karadag, Ali; Ovalioglu, Talat Cem; Jagadeesan, Bharathi; Sandhu, Gauravjot; Tanriover, Necmettin; Grande, Andrew W
2016-11-01
To evaluate the microsurgical anatomy of the fiber tract connections of the supplementary motor area (SMA) and pre-SMA, and examine its potential functional role with reference to clinical trials in the literature. Ten postmortem formalin-fixed human brains (20 sides) and 1 cadaveric head were prepared following Klingler's method. The fiber dissection was performed in a stepwise fashion, from lateral to medial and also from medial to lateral, under an operating microscope, with 3D images captured at each stage. Our findings were supported by in vivo magnetic resonance imaging tractography in 2 healthy subjects. The connections of the SMA complex, composed of the pre-SMA and the SMA proper, are composed of short "U" association fibers and the superior longitudinal fasciculus I, cingulum, claustrocortical fibers, callosal fibers, corticospinal tract, frontal aslant tract, and frontostriatal tract. The claustrocortical fibers may play an important role in the integration of motor, language, and limbic functions of the SMA complex. The frontostriatal tract connects the pre-SMA to the putamen and caudate nucleus, and also forms parts of both the internal capsule and the dorsal external capsule. The SMA complex has numerous connections throughout the cerebrum. An understanding of these connections is important for presurgical planning for lesions in the frontal lobe and helps explain symptoms related to SMA injury. Copyright © 2016 Elsevier Inc. All rights reserved.
Characterisation of myofibroblasts in fibrovascular tissues of primary and recurrent pterygia
Touhami, A; Di Pascuale, M A; Kawatika, T; Valle, M Del; Rosa, R H; Dubovy, S; Tseng, S C G
2005-01-01
Aims: To determine the presence and origin of myofibroblasts in pterygia. Methods: 86 specimens including head, body, and fibrovascular tissue from 52 primary and 34 recurrent pterygia and five exenterated eyes without pterygia were searched for the origin of myofibroblasts. All tissues were subjected to haematoxylin and eosin staining, immunohistochemistry using antibodies against alpha smooth muscle actin (α-SMA), desmin, vimentin, and caldesmon, and transmission electron microscopy (TEM). The phenotype of fibroblasts subcultured in a serum free medium from pterygium fibrovascular tissues was characterised by the above antibodies. Bundles of dense fibrous tissues were noted in 86% of the fibrovascular tissue specimens evaluated. Cells within these bundles were characterised as myofibroblasts based on positive staining to α-SMA, but negative to desmin and caldesmon, markers for smooth muscle cells. Interestingly, positive α-SMA staining was also found in the periorbital fibroadipose tissue posterior to Tenon’s capsule near the nasal conjunctiva in all exenterated specimens. All first passage fibroblasts expressed vimentin, some were positive to α-SMA, but all were negative to desmin or caldesmon. Cells in pterygium fibrovascular tissues showed ultrastructural features of intracytoplasmic bundles of microfilaments, consistent with myofibroblastic differentiation. Conclusion: These studies collectively demonstrate the presence of contractile myofibroblasts bundle in pterygia and in the periorbital fibroadipose tissue posterior to Tenon’s capsule of exenterated eyes without pterygium. PMID:15722301
Pancreatic acinar cell carcinoma extending into the common bile and main pancreatic ducts.
Yamaguchi, Rin; Okabe, Yoshinobu; Jimi, Atsuo; Shiota, Koji; Kodama, Takahito; Naito, Yoshiki; Yasunaga, Masafumi; Kinoshita, Hisafumi; Kojiro, Masamichi
2006-10-01
Acinar cell carcinoma (ACC) of the pancreas is relatively rare, accounting for only approximately 1% of all exocrine pancreatic tumors. A 69-year-old man was found to have a mass lesion measuring approximately 4 cm in diameter in the pancreatic head on ultrasound, abdominal dynamic CT, and percutaneous transhepatic cholangiography. Magnetic resonance cholangiopancreatography showed defect of the lower common bile duct (CBD) due to obstruction by the tumor cast. Histopathologically, the pancreatic head tumor invaded the main pancreatic duct (MPD) and CBD with extension into the CBD in a form of tumor cast. The tumor cells consisted of a solid proliferation with abundant eosinophilic cytoplasm and round nuclei in an acinar and trabecular fashion. A 55-year-old man with upper abdominal pain and nausea, had a cystic lesion approximately 3 cm in size in the pancreatic tail on CT. Histopathologically, the tumor was encapsulated by fibrous capsule and had extensive central necrosis with solid areas in the tumor periphery, and invaded with extension into the MPD in a form of tumor cast. The tumor cells resembled acinar cells in solid growths. Two resected cases of ACC with unusual tumor extension into the CBD and the MPD, respectively, are reported.
The effect of gender on foot anthropometrics in older people.
Paiva de Castro, Alessandra; Rebelatto, Jose Rubens; Aurichio, Thais Rabiatti
2011-08-01
Some questions remain regarding the anthropometric differences between the feet of young men and women, but the gap is much greater when dealing with older adults. No studies were found concerning these differences in an exclusively older adult population, which makes it difficult to manufacture shoes based on the specific anthropometric measurements of the older adult population and according to gender differences. To identify differences between the anthropometric foot variables of older men and women. Cross-sectional. 154 older women (69.0 ± 6.8 y) and 131 older men (69.0 ± 6.5 y). The foot evaluations comprised the variables of width, perimeter, height, length, 1st and 5th metatarsophalangeal angles, the Arch Index (AI), and the Foot Posture Index (FPI). A data analysis was performed using t test and a post hoc power analysis. Women showed significantly higher values for the width and perimeter of the toes, width of the metatarsal heads, and width of the heel and presented significantly lower values for the height of the dorsal foot after normalization of the data to foot length. The 1st and 5th metatarsophalangeal angles were smaller in the men. There were no differences between men and women with respect to AI and FPI. Overall, the current study shows evidence of differences between some of the anthropometric foot variables of older men and women that must be taken into account for the manufacture of shoes for older adults.
Capsule injection system for a hydraulic capsule pipelining system
Liu, Henry
1982-01-01
An injection system for injecting capsules into a hydraulic capsule pipelining system, the pipelining system comprising a pipeline adapted for flow of a carrier liquid therethrough, and capsules adapted to be transported through the pipeline by the carrier liquid flowing through the pipeline. The injection system comprises a reservoir of carrier liquid, the pipeline extending within the reservoir and extending downstream out of the reservoir, and a magazine in the reservoir for holding capsules in a series, one above another, for injection into the pipeline in the reservoir. The magazine has a lower end in communication with the pipeline in the reservoir for delivery of capsules from the magazine into the pipeline.
Improvement in Capsule Abort Performance Using Supersonic Aerodynamic Interaction by Fences
NASA Astrophysics Data System (ADS)
Koyama, Hiroto; Wang, Yunpeng; Ozawa, Hiroshi; Doi, Katsunori; Nakamura, Yoshiaki
The space transportation system will need advanced abort systems to secure crew against serious accidents. Here this study deals with the capsule-type space transportation systems with a Launch Abort System (LAS). This system is composed of a conic capsule as a Launch Abort Vehicle (LAV) and a cylindrical rocket as a Service Module (SM), and the capsule is moved away from the rocket by supersonic aerodynamic interactions in an emergency. We propose a method to improve the performance of the LAV by installing fences at the edges of surfaces on the rocket and capsule sides. Their effects were investigated by experimental measurements and numerical simulations. Experimental results show that the fences on the rocket and capsule surfaces increase the aerodynamic thrust force on the capsule by 70% in a certain clearance between the capsule and rocket. Computational results show the detailed flow fields where the centripetal flow near the surface on the rocket side is induced by the fence on the rocket side and the centrifugal flow near the surface on the capsule side is blocked by the fence on the capsule side. These results can confirm favorable effects of the fences on the performance of the LAS.
[A special soft tissue procedure for treatment of hallux valgus].
Waizy, H; Stukenborg-Colsman, C; Abbara-Czardybon, M; Emmerich, J; Windhagen, H; Frank, D
2011-02-01
Maintaining the corrected position of the first metatasophalangeal axis. Reducing postoperative stiffness by forgoing a medial capsular shift. Hallux valgus deformities or recurrent hallux valgus deformities. Existing osteoarthritis, joint stiffness, large bone defects, osteonecrosis. General medical contraindications to surgical interventions and anesthesiological procedures. Operation under regional anesthesia (foot block) or general anesthesia. Tourniquet. Longitudinal skin incision medial over the pseudexostosis of the first metatarsal bone. Preparing the tendon of the Musculus abductor hallucis. Detaching the tendon from the capsule. Incision of the joint capsule with protection of the extensor hallucis longus tendon and the dorsal neurovascular bundle in an L-wise manner. Osteotomy of the first metatarsal bone. Lax sutures of the capsule in correct position and reattachment of the Musculus abductor hallucis tendon shifted toward distal and dorsal, regarding the rotation of the hallux. Postoperative elevation of the operated foot. Analgesia with nonsteroidal antiinflammatory drugs. Postoperative weight-bearing according to the osteotomy. Passive mobilization of the metatarsophalangeal joint. Dressing for 4 weeks postoperatively in the corrected position. Radiologic control after 6 weeks. Hallux valgus orthosis at night and a toe spreader for a further 6 weeks. A total of 30 isolated hallux valgus deformities with a mean preoperative intermetatarsal (IMA) angle of 12.9° (range 11-15°) were operated with a chevron osteotomy. The mean follow-up was 14.4 (range 8-17) months. The mean dorsiflexion at the last follow-up was 44° (range 20-60°). Only 2 patients had a dorsiflexion <40°. The mean reduction of the IM angle was 5.6° (range 3-7°). One patient required wound revision. There was no infection or avascular necrosis of the metatarsal head observed in the patients. At follow-up, 20 (67%) patients were completely satisfied, 9 (30%) satisfied, and 1 (3%) was not satisfied.
Herrerias, Juan M; Leighton, Jonathan A; Costamagna, Guido; Infantolino, Anthony; Eliakim, Rami; Fischer, Doron; Rubin, David T; Manten, Howard D; Scapa, Eitan; Morgan, Douglas R; Bergwerk, Ari J; Koslowsky, Binyamin; Adler, Samuel N
2008-05-01
Capsule endoscopy (CE) of the small bowel has become a standard diagnostic tool, but there have been concerns regarding the risk of capsule retention in certain high-risk groups. The Agile patency system, an ingestible and dissolvable capsule with an external scanner, was developed to allow physicians to perform CE with greater confidence that the capsule will be safely excreted in patients at risk for capsule retention. Our purpose was to assess the ability of the device to help physicians identify which patients with known strictures may safely undergo CE. Patients with known strictures ingested the new patency capsule and underwent periodic scanning until it was excreted. The intestinal tract was considered to be sufficiently patent if the capsule was excreted intact or if the capsule was not detected by the scanner at 30 hours after ingestion. If patency was established, then standard CE was performed. International multicenter study. A total of 106 patients with known strictures. Agile patency system. Performance and safety of Agile patency system. A total of 106 patients ingested the patency capsule. Fifty-nine (56%) excreted it intact and subsequently underwent CE. There were no cases of capsule retention. Significant findings on CE were found in 24 (41%). There were 3 severe adverse events. These results suggest that the Agile patency system is a useful tool for physicians to use before CE in patients with strictures to avoid retention. This group of patients may have a high yield of clinically significant findings at CE. This capsule may determine whether patients who have a contraindication to CE may safely undergo CE and obtain useful diagnostic information.
Barham, Ahmad S; Tewes, Frederic; Healy, Anne Marie
2015-01-30
The primary objective of this paper is to compare the sorption characteristics of hydroxypropylmethylcellulose (HPMC) and hard gelatin (HG) capsules and their ability to protect capsule contents. Moisture sorption and desorption isotherms for empty HPMC and HG capsules have been investigated using dynamic vapour sorption (DVS) at 25°C. All sorption studies were analysed using the Young-Nelson model equations which distinguishes three moisture sorption types: monolayer adsorption moisture, condensation and absorption. Water vapour diffusion coefficients (D), solubility (S) and permeability (P) parameters of the capsule shells were calculated. ANOVA was performed with the Tukey comparison test to analyse the effect of %RH and capsule type on S, P, and D parameters. The moisture uptake of HG capsules were higher than HPMC capsules at all %RH conditions studied. It was found that values of D and P across HPMC capsules were greater than for HG capsules at 0-40 %RH; whereas over the same %RH range S values were higher for HG than for HPMC capsules. S values decreased gradually as the %RH was increased up to 60% RH. To probe the effect of moisture ingress, spray dried lactose was loaded into capsules. Phase evolution was characterised by scanning electron microscopy (SEM), X-ray powder diffraction (XRD), and differential scanning calorimetry (DSC). The capsules under investigation are not capable of protecting spray dried lactose from induced solid state changes as a result of moisture uptake. For somewhat less moisture sensitive formulations, HPMC would appear to be a better choice than HG in terms of protection of moisture induced deterioration. Copyright © 2014 Elsevier B.V. All rights reserved.
Production, deformation and mechanical investigation of magnetic alginate capsules
NASA Astrophysics Data System (ADS)
Zwar, Elena; Kemna, Andre; Richter, Lena; Degen, Patrick; Rehage, Heinz
2018-02-01
In this article we investigated the deformation of alginate capsules in magnetic fields. The sensitivity to magnetic forces was realised by encapsulating an oil in water emulsion, where the oil droplets contained dispersed magnetic nanoparticles. We solved calcium ions in the aqueous emulsion phase, which act as crosslinking compounds for forming thin layers of alginate membranes. This encapsulating technique allows the production of flexible capsules with an emulsion as the capsule core. It is important to mention that the magnetic nanoparticles were stable and dispersed throughout the complete process, which is an important difference to most magnetic alginate-based materials. In a series of experiments, we used spinning drop techniques, capsule squeezing experiments and interfacial shear rheology in order to determine the surface Young moduli, the surface Poisson ratios and the surface shear moduli of the magnetically sensitive alginate capsules. In additional experiments, we analysed the capsule deformation in magnetic fields. In spinning drop and capsule squeezing experiments, water droplets were pressed out of the capsules at elevated values of the mechanical load. This phenomenon might be used for the mechanically triggered release of water-soluble ingredients. After drying the emulsion-filled capsules, we produced capsules, which only contained a homogeneous oil phase with stable suspended magnetic nanoparticles (organic ferrofluid). In the dried state, the thin alginate membranes of these particles were rather rigid. These dehydrated capsules could be stored at ambient conditions for several months without changing their properties. After exposure to water, the alginate membranes rehydrated and became flexible and deformable again. During this swelling process, water diffused back in the capsule. This long-term stability and rehydration offers a great spectrum of different applications as sensors, soft actuators, artificial muscles or drug delivery systems.
Aihole, Jayalaxmi S; Vishnumurthy, G S; Babu, M Narendra
2016-11-15
Capsule endoscopy was invented to visualize the entire small intestine in a non- invasive manner in adults. 1 y, 9 mo-old boy presented with generalized edema for last 3 months. His routine investigations, including the upper gastrointestinal endoscopy, colonoscopy, and contrast enhanced computed tomography scan (CECT) were normal. In view of clinical suspicion of protein losing enteropathy, we planned capsule endoscopy. The capsule was not passed even after 3 weeks. Laparoscopy revealed impacted capsule in a dilated intestinal loop proximal to an ileal stricuture. Capsule endoscopy should be used judiciously in children.
Hou, Min; Tang, Qing; Xue, Qiang; Zhang, Xiaona; Liu, Yang; Yang, Sheng; Chen, Liechun; Xu, Xiaoyu
2017-01-04
Du Liang soft capsule (DL) is a traditional Chinese medicine for treating migraines; it is made from two Chinese herbs, including LigusticumstriatumDC., root; Angelica dahurica (Hoffm.) Benth. & Hook.f. ex Franch. & Sav., root. In the present study, we aimed to elucidate the pharmacodynamic action of DL and its mechanism in an animal model of migraines induced by glyceryl trinitrate (GTN). Sixty rats were randomly divided into six groups, including a normal control group, model control group, positive group (Sumatriptan 0.006gkg -1 ), and three DL groups (0.44, 1.31 and 3.93gkg -1 ). All rats were intragastrically treated with the corresponding treatment for 7 consecutive days, and they were subcutaneously injected with GTN (10mgkg -1 ) 30min after the last treatment, except in the normal control group. After model establishment, the behaviors of all rats, including head scratching, cage climbing, and the development of red ears were observed continuously by digital camera every 30min for 3h. Four hours after GTN treatment, all rats were anaesthetized and the blood and tissue samples were collected. Plasma calcitonin gene related to peptide (CGRP) and endothelin (ET) levels were measured using the radioimmunoassay method, and serum NO was determined by the colorimetric method. Afterwards, the brainstem tissues were dissected and washed with physiological saline, and divided evenly into two parts. One part was used to test the monoamine levels, including levels of 5-hydroxytryptamine (5-HT), norepinephrine (NE) and dopamine (DA), by the fluorometric method, and the other part was used to determine the nuclear factor kappaB (NF-κB) p65, nuclear c-fos, inducible nitric oxide synthase (iNOS), interleukin (IL)-1β (IL-1β), and cyclooxygenase-2 (COX-2) levels by Western blot analysis. In the pharmacodynamic action assay, DL (1.31 and 3.93gkg -1 ) greatly improved the abnormal behaviors of migraine rats, including head scratching and cage climbing, and the development of red ears. In the mechanism assay, compared with the control group, the plasma CGRP and serum NO levels and the brainstem 5-HT, NE and DA levels in the DL administration groups were significantly decreased; and the plasma ET levels were remarkably increased. Moreover, down-regulation of NF-κB p65, c-fos and pro-inflammatory cytokines, including iNOS, IL-1β and COX-2 in the brainstem in the DL administration groups were observed by Western blot analysis. The above results suggested that DL has a therapeutic effect on migraines, and its mechanism may be related to adjusting the level of neurotransmitters and vasoactive substances, consequently relieving neurogenic inflammation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Sekiya, Jon K; Jolly, John; Debski, Richard E
2012-02-01
Hill-Sachs defects have been associated with failed repairs for anterior shoulder instability. However, the biomechanical consequences of these defects are not well understood because of the complicated interaction between the passive soft tissue and bony stabilizers. The creation of a 25% Hill-Sachs defect would not significantly alter the glenohumeral translations but would increase the in situ forces in the glenohumeral capsule as well as the glenohumeral bony contact forces. Controlled laboratory study. A robotic/universal force-moment sensor (UFS) testing system was used to apply joint compression (22 N) and an anterior or posterior load (44 N) to cadaveric shoulders (n = 9) with the skin and deltoid removed (intact) at 3 glenohumeral joint positions (abduction/external rotation): 0°/0°, 30°/30°, and 60°/60° (corresponds to 90°/90° of shoulder abduction/external rotation). A 25% bony defect on the posterolateral humeral head (defect) was then created in the most common position of anterior shoulder dislocation (90°/90°), and the loading protocol was repeated. A nonparametric repeated-measures Friedman test with a Wilcoxon signed-rank post hoc test was performed to compare translations, in situ forces in the capsule, and bony contact forces between each state (P < .05). At 0°/0°, anterior translation significantly increased from 15.3 ± 8.2 mm to 16.6 ± 9.0 mm (P < .05) in response to an anterior load. At 30°/30°, anterior and posterior translations, respectively, significantly increased in response to both anterior (intact: 13.6 ± 7.1 mm vs defect: 14.2 ± 7 mm; P < .05) and posterior loads (intact: 15.7 ± 5.8 mm vs defect: 17.7 ± 5.1 mm; P < .05). In situ force in the capsule during anterior loading was increased in the defect state at both 60°/60° (intact: 38.9 ± 14.4 N vs defect: 43.2 ± 15.9 N; P < .05) and 30°/30° (intact: 39.6 ± 13.8 N vs defect: 45.6 ± 9.3 N; P < .05). The medial bony contact forces were also increased in the defect state at 30°/30° (intact: 25.0 ± 13.8 N vs defect: 28.9 ± 13.2 N; P < .05) during anterior loading. We believe that the stabilizing function of the intact capsule was the primary contributor to the finding of only small increases of anterior translation, capsule forces, and bony contact forces observed with a 25% Hill-Sachs defect in response to an anterior load. These findings imply that a 25% Hill-Sachs defect in isolation may not be responsible for recurrent instability if the function of the capsule is restored to the intact state and that the presence of the Hill-Sachs defect may be a marker for significant concomitant injury to the anterior glenoid rim. However, the small changes in these parameters may have long-term implications for the development of osteoarthritis.
Morphometry of boar sperm head and flagellum in semen backflow after insemination.
García-Vázquez, Francisco Alberto; Hernández-Caravaca, Iván; Yánez-Quintana, Wellington; Matás, Carmen; Soriano-Úbeda, Cristina; Izquierdo-Rico, María José
2015-09-01
Once deposited in the female reproductive system, sperm begin their competition and undergo a selection to reach the site of fertilization. Little is known about the special characteristics of sperm that reach the oviduct and are able to fertilize, with even less information on the role of sperm dimension and shape in transport and fertilization. Here, we examine whether sperm morphometry could be involved in their journey within the uterus. For this purpose, sperm head dimension (length, width, area, and perimeter) and shape (shape factor, ellipticity, elongation, and regularity), and flagellum length were analyzed in the backflow at different times after insemination (0-15, 16-30, and 31-60 minutes). Sperm morphometry in the backflow was also analyzed taking into account the site of semen deposition (cervical vs. intrauterine). Finally, flagellum length was measured at the uterotubal junction. Sperm analyzed in the backflow were small (head and flagellum) with different head shapes compared with sperm observed in the dose before insemination. The site of deposition influenced head morphometry and tail size both being smaller in the backflow after cervical insemination compared with intrauterine insemination. Mean tail length of sperm collected in the backflow was smaller than that in the insemination dose and at the uterotubal junction. Overall, our results suggest that sperm size may be involved in sperm transport either because of environment or through sperm selection and competence on their way to encounter the female gamete. Copyright © 2015 Elsevier Inc. All rights reserved.
Structure and Composition of the Bacillus anthracis Capsule
Avakyan, A. A.; Katz, L. N.; Levina, K. N.; Pavlova, I. B.
1965-01-01
Avakyan, A. A. (Academy of Medical Sciences, Moscow, USSR), L. N. Katz, K. N. Levina, and I. B. Pavlova. Structure and composition of the Bacillus anthracis capsule. J. Bacteriol. 90:1082–1095. 1965.—Observations by various methods of light microscopy (phase contrast, dark-field, and fluorescence) revealed the complex structure of the Bacillus anthracis capsule, which changes regularly during the growth cycle of the culture. Special cytological methods of staining the capsule made it possible to study its fine structure, which is not revealed by negative staining with India ink. For example, the capsule shows a membranelike outline, fine transverse lines, and interruptions and transverse septa traversing the entire capsule. By using cytochemical methods, it was found that the capsule has a stratified structure and that the various layers of the capsule differ as to the value of the isoelectric point, metachromatic ability, sensitivity to various enzymes, and, consequently, chemical composition. It was thus shown that the membranelike outline of the capsule consists of peptides and neutral mucopolysaccharides. The middle part of the capsule consists of a complex of substances of both polysaccharide and protein nature, and the inner part consists of acid mucopolysaccharides. Observation of the capsular forms of B. anthracis by means of an electron microscope revealed differences in the osmiophilia and submicroscopic structure of the membranelike outline and the middle and inner parts of the capsule. Immunochemical studies conducted by the fluorescent-antibody method revealed localization of antigens in different parts of the capsule, and made it possible to differentiate the capsular antigens according to their serum-staining ability and according of their relations to enzymes, i.e., their chemical composition. This paper concerns the possibility of studying the fine structure of bacterial capsules in fixed preparations, and the differences and similarities of the antigens of the capsule and cell wall of B. anthracis and of the related species, B. megaterium. Images PMID:4954516
Engineering fluorescent poly(dopamine) capsules.
Chen, Xi; Yan, Yan; Müllner, Markus; van Koeverden, Martin P; Noi, Ka Fung; Zhu, Wei; Caruso, Frank
2014-03-18
The recent development of poly(dopamine) (PDA) capsules provides new opportunities for their application in biology and medicine. To advance the biomedical application of PDA capsules, strategies that enable the preparation of fluorescently labeled PDA (F-PDA) capsules are required, as this will allow evaluation of their cellular interactions using a range of fluorescence-based techniques. Herein, we report a facile approach for the fabrication of F-PDA capsules via the polymerization of dopamine (DA) on sacrificial templates in the presence of hydrogen peroxide (H2O2). F-PDA capsules with well-defined sizes are prepared by templating different organic and inorganic particles. The resulting F-PDA capsules show negligible cytotoxicity in HeLa cells after incubation for 48 h. We also demonstrate visualization of the F-PDA capsules following internalization by HeLa cells using conventional fluorescence microscopy, en route toward detailed investigations on their biological interactions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rice, Neal G.; Vu, M.; Kong, C.
Capsule drive in National Ignition Facility (NIF) indirect drive implosions is generated by x-ray illumination from cylindrical hohlraums. The cylindrical hohlraum geometry is axially symmetric but not spherically symmetric causing capsule-fuel drive asymmetries. We hypothesize that fabricating capsules asymmetric in wall thickness (shimmed) may compensate for drive asymmetries and improve implosion symmetry. Simulations suggest that for high compression implosions Legendre mode P 4 hohlraum flux asymmetries are the most detrimental to implosion performance. General Atomics has developed a diamond turning method to form a GDP capsule outer surface to a Legendre mode P 4 profile. The P 4 shape requiresmore » full capsule surface coverage. Thus, in order to avoid tool-lathe interference flipping the capsule part way through the machining process is required. This flipping process risks misalignment of the capsule causing a vertical step feature on the capsule surface. Recent trials have proven this step feature height can be minimized to ~0.25 µm.« less
Reptilia: Testudines: Emydidae Graptemys gibbonsi - Pascagoula Map Turtle
Lovich, Jeffrey E.; Ennen, Joshua R.
2014-01-01
The Pascagoula Map Turtle, Graptemys gibbonsi, is a large riverine species that exhibits pronounced sexual dimorphism, where females attain a maximum carapace length (CL) of 295 mm and males a maximum of 141 mm (Lovich et al. 2009). Mean adult female CL (248 mm) can be well over twice the mean CL of adult males (104 mm; Gibbons and Lovich 1990, Lovich et al. 2009). In addition, females have conspicuously enlarged heads (37.9 mm, SD = 14.0 mm) with broad alveolar surfaces (12.1 mm, SD = 4.9) compared to males (head width – 16.4 mm, SD = 1.1 mm; alveolar width – 4.3 mm, SD = 0.40 mm; Lindeman, unpublished data). Males have longer tails with the vent posterior to the edge of the carapace. Both sexes have relatively flat plastrons. Similar to other species within the pulchra clade, Graptemys gibbonsi possess a high-domed shell with a median keel. The median carapace keel is composed of prominent spines on the posterior portions of the second and third vertebrals. A broken black stripe, most pronounced anteriorly, marks the median keel of the vertebrals, and pleural scutes 1– 3 have a network of intersecting yellow lines or circular yellow markings on the distal parts. The plastron is pale yellow with dark pigment on some seams. Ground color of the head and limbs is brown to olive with light yellow or yellowish-green stripes and blotches. The yellow pigment on the upper marginal scutes is wide in comparison to other members of the pulchra clade.Hatchling pigmentation patterns resemble those of adults, but with more conspicuous patterns on the pleural scutes. Similarly, the plastron of hatchlings commonly has more dark pigmentation along the seams than adults. The shell is highly serrated along the edge of the carapace and the vertebral keel is more pronounced than in adults.
Manchado de Sola, Francisco; Vilches, Manuel; Prezado, Yolanda; Lallena, Antonio M
2018-05-15
The purpose of this study was to assess the effects of brain movements induced by heartbeat on dose distributions in synchrotron micro- and minibeam radiation therapy and to develop a model to help guide decisions and planning for future clinical trials. The Monte Carlo code PENELOPE was used to simulate the irradiation of a human head phantom with a variety of micro- and minibeam arrays, with beams narrower than 100 μm and above 500 μm, respectively, and with radiation fields of 1 × 2 cm and 2 × 2 cm. The dose in the phantom due to these beams was calculated by superposing the dose profiles obtained for a single beam of 1 μm × 2 cm. A parameter δ, accounting for the total displacement of the brain during the irradiation and due to the cardiosynchronous pulsation, was used to quantify the impact on peak-to-valley dose ratios and the full width at half maximum. The difference between the maximum (at the phantom entrance) and the minimum (at the phantom exit) values of the peak-to-valley dose ratio reduces when the parameter δ increases. The full width at half maximum remains almost constant with depth for any δ value. Sudden changes in the two quantities are observed at the interfaces between the various tissues (brain, skull, and skin) present in the head phantom. The peak-to-valley dose ratio at the center of the head phantom reduces when δ increases, remaining above 70% of the static value only for minibeams and δ smaller than ∼200 μm. Optimal setups for brain treatments with synchrotron radiation micro- and minibeam combs depend on the brain displacement due to cardiosynchronous pulsation. Peak-to-valley dose ratios larger than 90% of the maximum values obtained in the static case occur only for minibeams and relatively large dose rates. © 2018 American Association of Physicists in Medicine.
Warren, Ian; Smith, Hazel
2007-03-01
Stalk-eyed flies of the family Diopsidae exhibit a unique form of hypercephaly, which has evolved under both natural and sexual selection. Male hypercephaly is used by female diopsids as an indicator of male quality. By choosing to mate with males expressing the most-exaggerated hypercephaly, females can benefit both from the enhanced fertility of these males and the transmission of other heritable advantages to their offspring. Stalk-eyed flies are close relatives of the model organism, Drosophila melanogaster. We have shown that similar genetic and cellular mechanisms regulate the initial development of the head capsule in fruitflies and diopsids. The great diversity of stalk-eyed fly species, exhibiting varying degrees of hypercephaly and sexual dimorphism, constitutes a major advantage for comparative studies of their development and evolution.
Visualization of a Capsule Entry Vehicle Reaction-Control System (RCS) Thruster
NASA Technical Reports Server (NTRS)
Danehy, P. M.; Wilkes, J. A.; Brauckmann, G. J.; Alderfer, D. W.; Jones, S. B.; Patry, D. P.
2006-01-01
Planar laser-induced fluorescence (PLIF) was used to visualize the reaction control system (RCS) jet flow emanating from the aft-body of an Apollo-geometry capsule test article in the NASA Langley Research Center 31-Inch Mach 10 Air wind tunnel. The RCS jet was oriented normal to the aft surface of the model and had a nominal Mach number of 2.94. The composition of the jet gas by mass was 95% nitrogen (N2) and 5% nitric oxide (NO). The RCS jet flowrate varied between zero and 0.5 standard liters per minute and the angle of attack and tunnel stagnation pressure were also varied. PLIF was used to excite the NO molecules for flow visualization. These flow visualization images were processed to determine the trajectory and to quantify the flapping of the RCS jet. The spatial resolution of the jet trajectory measurement was about 1 mm and the single-shot precision of the measurement was estimated to be 0.02 mm in the far field of the jet plume. The jet flapping, measured by the standard deviation of the jet centerline position was as large as 0.9 mm, while the jet was 1.5-4 mm in diameter (full width at half maximum). Schlieren flow visualization images were obtained for comparison with the PLIF. Surface pressures were also measured and presented. Virtual Diagnostics Interface (VIDI) technology developed at NASA Langley was used to superimpose and visualize the data sets. The measurements demonstrate some of the capabilities of the PLIF method while providing a test case for computational fluid dynamics (CFD) validation.
Michelin, Paul; Trintignac, Adrien; Dacher, Jean Nicolas; Carvalhana, Gilbert; Lefebvre, Valentin; Duparc, Fabrice
2014-12-01
The superior part of the rotator cuff consists of the anterior (SSa) and posterior (SSp) parts of the supraspinatus tendon, the infraspinatus (IS) tendon plus the articular capsule. An overlap of the distal SSp tendon by the anterior part of the IS one has been anatomically demonstrated; the insertion area of the IS is more anterior than currently believed. The aim of our study was to assess this complex architecture through standard MRI scans. Twenty-five healthy volunteers underwent a shoulder MRI. Three planes T2 fat saturation sequences were read in consensus by two radiologists. The SSa, the SSp, the IS tendons and the articular capsule were assessed for visibility. The patterns of demarcation of each structure from adjacent ones were assessed. The width and the thickness of each tendinous band were measured on sagittal images. The SSa, the SSp and the IS tendons were distinguishable in all patients. The anterior part of the IS tendon overlapped the SSp tendon to reach a quite anterior insertion into the greater tuberosity of the humerus. The SSa, the SSp and the IS tendons were 6.5-3.4, 15.1-2.8 and 26.8-2.2 mm wide and thick, respectively. MR images of the normal superior rotator cuff are consistent with latest anatomical descriptions. The distal superposition of the IS over the SSp tendon should be considered regarding the linear increased signal areas and the commonly named "partial thickness ruptures" of the superior rotator cuff as well as the fatty infiltration of the IS muscle.
The radial approach to the wrist with styloidectomy: A cadaver study.
Lecoq, F-A; Sébilo, A; Bellemère, P
2017-09-01
The radial approach to the wrist is already used in several surgical techniques such as radial styloidectomy and Zaidemberg's vascularized radial graft. The aim of our work was to describe the surgical anatomy of that approach and to determine the acceptable limits of radial oblique styloidectomy that does not damage the anterior and posterior radiocarpal ligaments. This radial approach was performed on 11 cadaver specimens. The superficial branches of the radial nerve and the antebrachial cephalic vein were carefully located in the superficial plane. The radiocarpal articular capsule was opened longitudinally between the first and second compartments of the extensor tendons. We drew the oblique radial styloidectomy line at 3, 6 and 9mm from the apex of radial styloid process on the articular surface and then measured the width of ligaments theoretically taken away by the styloidectomy. An oblique radial styloidectomy of less than 6mm preserved the anterior and posterior radiocarpal ligaments. There was one case of radial artery damage while opening the joint capsule. The radial approach to the wrist as described in this work provided good access to the radial styloid process, the radioscaphoid joint and the proximal pole of the scaphoid, if the approach is done carefully to preserve the superficial branches of the radial nerve, the antebrachial cephalic vein and the radial artery. Radial styloidectomy can be performed up to 6mm from the apex without significantly damaging the radiocarpal ligaments, particularly the volar ones. Copyright © 2017 SFCM. Published by Elsevier Masson SAS. All rights reserved.
Analysis of Fission Products on the AGR-1 Capsule Components
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paul A. Demkowicz; Jason M. Harp; Philip L. Winston
2013-03-01
The components of the AGR-1 irradiation capsules were analyzed to determine the retained inventory of fission products in order to determine the extent of in-pile fission product release from the fuel compacts. This includes analysis of (i) the metal capsule components, (ii) the graphite fuel holders, (iii) the graphite spacers, and (iv) the gas exit lines. The fission products most prevalent in the components were Ag-110m, Cs 134, Cs 137, Eu-154, and Sr 90, and the most common location was the metal capsule components and the graphite fuel holders. Gamma scanning of the graphite fuel holders was also performed tomore » determine spatial distribution of Ag-110m and radiocesium. Silver was released from the fuel components in significant fractions. The total Ag-110m inventory found in the capsules ranged from 1.2×10 2 (Capsule 3) to 3.8×10 1 (Capsule 6). Ag-110m was not distributed evenly in the graphite fuel holders, but tended to concentrate at the axial ends of the graphite holders in Capsules 1 and 6 (located at the top and bottom of the test train) and near the axial center in Capsules 2, 3, and 5 (in the center of the test train). The Ag-110m further tended to be concentrated around fuel stacks 1 and 3, the two stacks facing the ATR reactor core and location of higher burnup, neutron fluence, and temperatures compared with Stack 2. Detailed correlation of silver release with fuel type and irradiation temperatures is problematic at the capsule level due to the large range of temperatures experienced by individual fuel compacts in each capsule. A comprehensive Ag 110m mass balance for the capsules was performed using measured inventories of individual compacts and the inventory on the capsule components. For most capsules, the mass balance was within 11% of the predicted inventory. The Ag-110m release from individual compacts often exhibited a very large range within a particular capsule.« less
Magnesium Ion Acts as a Signal for Capsule Induction in Cryptococcus neoformans.
Rathore, Sudarshan S; Raman, Thiagarajan; Ramakrishnan, Jayapradha
2016-01-01
Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF). To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C. neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C. neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C. neoformans and 37°C for Clinical C. neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C. neoformans. While investigating the individual components of artificial CSF, we found that Mg(2+) ions influence the capsule growth in both environmental and clinical strains of C. neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60, and CAP64 in various capsule inducing media and in different concentrations of Mg(2+) and Ca(2+). Our results on gene expression suggest that, Mg(2+) does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg(2+) ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C. neoformans.
Krok, Karen L.; Wagennar, Rebecca Rankin; Kantsevoy, Sergey V.
2016-01-01
Introduction Capsule endoscopy has been suggested as a potential alternative to endoscopy for detection of esophagogastric varices and severe portal hypertensive gastropathy (PHG). The aim of the study was to determine whether PillCam esophageal capsule endoscopy could replace endoscopy for screening purposes. Material and methods Sixty-two patients with cirrhosis with no previous variceal bleeding had PillCam capsule endoscopy and video endoscopy performed on the same day. Sensitivity, specificity, and positive and negative predictive values (PPV, NPV) of capsule endoscopy were compared to endoscopy for the presence and severity of esophageal and gastric varices, PHG and the need for primary prophylaxis. Patients’ preference was assessed by a questionnaire. Results Four (6%) patients were unable to swallow the capsule. Sensitivity, specificity, PPV and NPV of capsule endoscopy for detecting any esophageal varices (92%, 50%, 92%, 50%), large varices (55%, 91%, 75%, 80%), variceal red signs (58%, 87%, 69%, 80%), PHG (95%, 50%, 95%, 50%), and the need for primary prophylaxis (91%, 57%, 78%, 80%) were not optimal, with only moderate agreement (κ) between capsule and upper GI endoscopy. Had only a capsule endoscopy been performed, 12 (21.4%) patients would have received inappropriate treatment. Capsule endoscopy also failed to detect (0/13) gastric varices. The majority of patients ranked capsule endoscopy as more convenient (69%) and their preferred (61%) method. Conclusions Despite the preference expressed by patients for capsule endoscopy, we believe that upper GI endoscopy should remain the preferred screening method for primary prophylaxis. PMID:27186182
Reinforcing effects of caffeine in coffee and capsules.
Griffiths, R R; Bigelow, G E; Liebson, I A
1989-09-01
In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee.
Reinforcing effects of caffeine in coffee and capsules.
Griffiths, R R; Bigelow, G E; Liebson, I A
1989-01-01
In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee. PMID:2794839
Short article: Aspiration of capsule endoscopes: a comprehensive review of the existing literature.
Yung, Diana E; Plevris, John N; Koulaouzidis, Anastasios
2017-04-01
Capsule endoscopy (CE) has an excellent safety profile. Although retention is the most cited complication, capsule aspiration is less frequent and is often reported only as isolated cases. This study represents a systematic effort to compile and scrutinize the available data on capsule aspiration to provide comprehensive and conclusive information on this CE complication. A systematic literature search was performed in PubMed, Embase and Chinese National Knowledge Infrastructure. The search terms used were 'capsule endoscopy' AND 'aspiration' (both terms searched as keyword and MeSH). We included case reports and/or series on capsule aspiration, as well as observational cohort studies that reported capsule aspiration among their complications/outcomes. Thirty-four case reports with 37 cases of capsule aspiration were identified. A further four observational studies reported aspiration as part of a cohort of patients undergoing CE. 94.6% of aspirations occurred in elderly men. 87.1% had significant comorbidities. 59.5% had symptoms on aspiration, with cough reported most frequently. The most common location of aspiration was the right main bronchus. Half of the patients required intervention for capsule retrieval; bronchoscopy was the most common management, with good effect. There was a single fatality following capsule aspiration, not directly related to the procedure, and one case of aspiration pneumonia. Outcomes were good for all other patients. The estimated overall aspiration rate is 0.1%. Although very rare and generally safely managed, capsule aspiration should be anticipated in certain patient groups and capsule administration should be approached with necessary precautions.
Polar tent for reduced perturbation of NIF ignition capsules
NASA Astrophysics Data System (ADS)
Hammel, B. A.; Pickworth, L.; Stadermann, M.; Field, J.; Robey, H.; Scott, H. A.; Smalyuk, V.
2016-10-01
In simulations, a tent that contacts the capsule near the poles and departs tangential to the capsule surface greatly reduces the capsule perturbation, and the resulting mass injected into the hot-spot, compared to current capsule support methods. Target fabrication appears feasible with a layered tent (43-nm polyimide + 8-nm C) for increased stiffness. We are planning quantitative measurements of the resulting shell- ρR perturbation near peak implosion velocity (PV) using enhanced self-emission backlighting, achieved by adding 1% Ar to the capsule fill in Symcaps (4He + H). Layered DT implosions are also planned for an integrated test of capsule performance. We will describe the design and simulation predictions. Prepared by LLNL under Contract DE-AC52-07NA27344.
Investigation of albumin-derived perfluorocarbon-based capsules by holographic optical trapping
Köhler, Jannis; Ruschke, Jegor; Ferenz, Katja Bettina; Esen, Cemal; Kirsch, Michael; Ostendorf, Andreas
2018-01-01
Albumin-derived perfluorocarbon-based capsules are promising as artificial oxygen carriers with high solubility. However, these capsules have to be studied further to allow initial human clinical tests. The aim of this paper is to provide and characterize a holographic optical tweezer to enable contactless trapping and moving of individual capsules in an environment that mimics physiological (in vivo) conditions most effectively in order to learn more about the artificial oxygen carrier behavior in blood plasma without recourse to animal experiments. Therefore, the motion behavior of capsules in a ring shaped or vortex beam is analyzed and optimized on account of determination of the optical forces in radial and axial direction. In addition, due to the customization and generation of dynamic phase holograms, the optical tweezer is used for first investigations on the aggregation behavior of the capsules and a statistical evaluation of the bonding in dependency of different capsule sizes is performed. The results show that the optical tweezer is sufficient for studying individual perfluorocarbon-based capsules and provide information about the interaction of these capsules for future use as artificial oxygen carriers. PMID:29552409
Nanocomposite capsules with directional, pulsed nanoparticle release.
Udoh, Christiana E; Cabral, João T; Garbin, Valeria
2017-12-01
The precise spatiotemporal delivery of nanoparticles from polymeric capsules is required for applications ranging from medicine to materials science. These capsules derive key performance aspects from their overall shape and dimensions, porosity, and internal microstructure. To this effect, microfluidics provide an exceptional platform for emulsification and subsequent capsule formation. However, facile and robust approaches for nanocomposite capsule fabrication, exhibiting triggered nanoparticle release, remain elusive because of the complex coupling of polymer-nanoparticle phase behavior, diffusion, phase inversion, and directional solidification. We investigate a model system of polyelectrolyte sodium poly(styrene sulfonate) and 22-nm colloidal silica and demonstrate a robust capsule morphology diagram, achieving a range of internal morphologies, including nucleated and bicontinuous microstructures, as well as isotropic and non-isotropic external shapes. Upon dissolution in water, we find that capsules formed with either neat polymers or neat nanoparticles dissolve rapidly and isotropically, whereas bicontinuous, hierarchical, composite capsules dissolve via directional pulses of nanoparticle clusters without disrupting the scaffold, with time scales tunable from seconds to hours. The versatility, facile assembly, and response of these nanocomposite capsules thus show great promise in precision delivery.
Bao, Guanqun; Mi, Liang; Geng, Yishuang; Zhou, Mingda; Pahlavan, Kaveh
2014-01-01
Wireless Capsule Endoscopy (WCE) is progressively emerging as one of the most popular non-invasive imaging tools for gastrointestinal (GI) tract inspection. As a critical component of capsule endoscopic examination, physicians need to know the precise position of the endoscopic capsule in order to identify the position of intestinal disease. For the WCE, the position of the capsule is defined as the linear distance it is away from certain fixed anatomical landmarks. In order to measure the distance the capsule has traveled, a precise knowledge of how fast the capsule moves is urgently needed. In this paper, we present a novel computer vision based speed estimation technique that is able to extract the speed of the endoscopic capsule by analyzing the displacements between consecutive frames. The proposed approach is validated using a virtual testbed as well as the real endoscopic images. Results show that the proposed method is able to precisely estimate the speed of the endoscopic capsule with 93% accuracy on average, which enhances the localization accuracy of the WCE to less than 2.49 cm.
Development of Head Injury Assessment Reference Values Based on NASA Injury Modeling
NASA Technical Reports Server (NTRS)
Somers, Jeffrey T.; Melvin, John W.; Tabiei, Ala; Lawrence, Charles; Ploutz-Snyder, Robert; Granderson, Bradley; Feiveson, Alan; Gernhardt, Michael; Patalak, John
2011-01-01
NASA is developing a new capsule-based, crewed vehicle that will land in the ocean, and the space agency desires to reduce the risk of injury from impact during these landings. Because landing impact occurs for each flight and the crew might need to perform egress tasks, current injury assessment reference values (IARV) were deemed insufficient. Because NASCAR occupant restraint systems are more effective than the systems used to determine the current IARVs and are similar to NASA s proposed restraint system, an analysis of NASCAR impacts was performed to develop new IARVs that may be more relevant to NASA s context of vehicle landing operations. Head IARVs associated with race car impacts were investigated by completing a detailed analysis of all of the 2002-2008 NASCAR impact data. Specific inclusion and exclusion criteria were used to select 4071 impacts from the 4015 recorder files provided (each file could contain multiple impact events). Of the 4071 accepted impacts, 274 were selected for numerical simulation using a custom NASCAR restraint system and Humanetics Hybrid-III 50th percentile numerical dummy model in LS-DYNA. Injury had occurred in 32 of the 274 selected impacts, and 27 of those injuries involved the head. A majority of the head injuries were mild concussions with or without brief loss of consciousness. The 242 non-injury impacts were randomly selected and representative of the range of crash dynamics present in the total set of 4071 impacts. Head dynamics data (head translational acceleration, translational change in velocity, rotational acceleration, rotational velocity, HIC-15, HIC-36, and the Head 3ms clip) were filtered according to SAE J211 specifications and then transformed to a log scale. The probability of head injury was estimated using a separate logistic regression analysis for each log-transformed predictor candidate. Using the log transformation constrains the estimated probability of injury to become negligible as IARVs approach zero. For the parameters head translational acceleration, head translational velocity change, head rotational acceleration, HIC-15, and HIC-36, conservative values (in the lower 95% confidence interval) that gave rise to a 5% risk of any injury occurring were estimated as 40.0 G, 7.9 m/s, 2200 rad/s2, 98.4, and 77.4 respectively. Because NASA is interested in the consequence of any particular injury on the ability of the crew to perform egress tasks, the head injuries that occurred in the NASCAR dataset were classified according to a NASA-developed scale (Classes I - III) for operationally relevant injuries, which classifies injuries on the basis of their operational significance. Additional analysis of the data was performed to determine the probability of each injury class occurring, and this was estimated using an ordered probit model. For head translational acceleration, head translational velocity change, head rotational acceleration, head rotational velocity, HIC-36, and head 3ms clip, conservative values of IARVs that produced a 5% risk of Class II injury were estimated as 50.7 G, 9.5 m/s, 2863 rad/s2, 11.0 rad/s, 30.3, and 46.4 G respectively. The results indicate that head IARVs developed from the NASCAR dataset may be useful to protect crews during landing impact.
[Improvement of Digital Capsule Endoscopy System and Image Interpolation].
Zhao, Shaopeng; Yan, Guozheng; Liu, Gang; Kuang, Shuai
2016-01-01
Traditional capsule image collects and transmits analog image, with weak anti-interference ability, low frame rate, low resolution. This paper presents a new digital image capsule, which collects and transmits digital image, with frame rate up to 30 frames/sec and pixels resolution of 400 x 400. The image is compressed in the capsule, and is transmitted to the outside of the capsule for decompression and interpolation. A new type of interpolation algorithm is proposed, which is based on the relationship between the image planes, to obtain higher quality colour images. capsule endoscopy, digital image, SCCB protocol, image interpolation
The effects of hematoma on implant capsules.
Caffee, H H
1986-02-01
Hematoma surrounding an implant is one of the many factors that have been suggested as possible causes for scar capsule contracture. In this study, experiments were designed to determine the influence of hematoma on the incidence and severity of capsule contracture in rabbits. Two implants were placed in each animal, 1 with a surrounding hematoma and 1 control. Capsules were evaluated subjectively and compared objectively with measurements of deformability, surface area, and capsule thickness. No differences were found with any of the objective criteria, which suggests that hematoma may not be a noteworthy cause of implant capsule contracture.
Snyder, Michael E; Lindsell, Luke B
2010-02-01
Puncturing the anterior capsule in a patient with a very soft lens, an elastic capsule, and/or deficient zonular countertraction can be challenging even with a sharp needle or blade. The crossed-swords, capsule-pinch technique capitalizes on opposing forces from 2 needles directed toward each other with a "pinch" of the capsule between their tips. This affords a controlled and facile puncture of the capsule without creating stress on the zonules or anteroposterior displacement of the lens. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Kim, Hee Man; Choi, Ja Sung; Cho, Jae Hee
2014-04-30
The magnetic capsule endoscope has been modified to be fixed inside the stomach and to monitor the gastric motility. This pilot trial was designed to investigate the feasibility of the magnetic capsule endoscope for monitoring gastric motility. The magnetic capsule endoscope was swallowed by the healthy volunteer and maneuvered by the external magnet on his abdomen surface inside the stomach. The magnetic capsule endoscope transmitted image of gastric peristalsis. This simple trial suggested that the real-time ambulatory monitoring of gastric motility should be feasible by using the magnetic capsule endoscope.
Dual-probe near-field fiber head with gap servo control for data storage applications.
Fang, Jen-Yu; Tien, Chung-Hao; Shieh, Han-Ping D
2007-10-29
We present a novel fiber-based near-field optical head consisting of a straw-shaped writing probe and a flat gap sensing probe. The straw-shaped probe with a C-aperture on the end face exhibits enhanced transmission by a factor of 3 orders of magnitude over a conventional fiber probe due to a hybrid effect that excites both propagation modes and surface plasmon waves. In the gap sensing probe, the spacing between the probe and the disk surface functions as an external cavity. The high sensitivity of the output power to the change in the gap width is used as a feedback control signal. We characterize and design the straw-shaped writing probe and the flat gap sensing probe. The dual-probe system is installed on a conventional biaxial actuator to demonstrate the capability of flying over a disk surface with nanometer position precision.
Thermoregulation of Capsule Production by Streptococcus pyogenes
Kang, Song Ok; Wright, Jordan O.; Tesorero, Rafael A.; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong
2012-01-01
The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface. PMID:22615992
Lien, Gi-Shih; Liu, Chih-Wen; Jiang, Joe-Air; Chuang, Cheng-Long; Teng, Ming-Tsung
2012-07-01
This paper presents a novel solution of a hand-held external controller to a miniaturized capsule endoscope in the gastrointestinal (GI) tract. Traditional capsule endoscopes move passively by peristaltic wave generated in the GI tract and the gravity, which makes it impossible for endoscopists to manipulate the capsule endoscope to the diagnostic disease areas. In this study, the main objective is to present an endoscopic capsule and a magnetic field navigator (MFN) that allows endoscopists to remotely control the locomotion and viewing angle of an endoscopic capsule. The attractive merits of this study are that the maneuvering of the endoscopic capsule can be achieved by the external MFN with effectiveness, low cost, and operation safety, both from a theoretical and an experimental point of view. In order to study the magnetic interactions between the endoscopic capsule and the external MFN, a magnetic-analysis model is established for computer-based finite-element simulations. In addition, experiments are conducted to show the control effectiveness of the MFN to the endoscopic capsule. Finally, several prototype endoscopic capsules and a prototype MFN are fabricated, and their actual capabilities are experimentally assessed via in vitro and ex vivo tests using a stomach model and a resected porcine stomach, respectively. Both in vitro and ex vivo test results demonstrate great potential and practicability of achieving high-precision rotation and controllable movement of the capsule using the developed MFN.
Kim, J S; Sung, I H; Kim, Y T; Kim, D E; Jang, Y H
2007-11-01
For the purpose of optimizing the design of the locomotion mechanism as well as the body shape of a self-propelled capsule endoscope, an analytical model for the prediction of frictional resistance of the capsule moving inside the small intestine was first developed. The model was developed by considering the contact geometry and viscoelasticity of the intestine, based on the experimental investigations on the material properties of the intestine and the friction of the capsule inside the small intestine. In order to verify the model and to investigate the distributions of various stress components applied to the capsule, finite element (FE) analyses were carried out. The comparison of the frictional resistance between the predicted and the experimental values suggested that the proposed model could predict the frictional force of the capsule with reasonable accuracy. Also, the FE analysis results of various stress components revealed the stress relaxation of the intestine and explained that such stress relaxation characteristics of the intestine resulted in lower frictional force as the speed of the capsule decreased. These results suggested that the frontal shape of the capsule was critical to the design of the capsule with desired frictional performance. It was shown that the proposed model can provide quantitative estimation of the frictional resistance of the capsule under various moving conditions inside the intestine. The model is expected to be useful in the design optimization of the capsule locomotion inside the intestine.
Proposed pushered single shell capsule design for the investigation of mid/high Z mix on the NIF
NASA Astrophysics Data System (ADS)
Sacks, Ryan; Tipton, Robert; Graziani, Frank
2016-05-01
The CD Mix campaign has given a detailed explination of the mix mechanics in the current ignition capsule designs by investigating the relationship between material mixing, shell-fuel interfaces, and the change in thermonuclear yield given a deuterated layer in the capsule. Alternative ignition scenarios include the use of double shell designs that incorporate high-Z material in the capsule. Simulations are conducted on a proposed capsule platform using the ARES code on a scaled capsule design using a partially reduced glass capsule design. This allows for the inclusion of deuterium on the inner surface of the pusher layer similar to the CD mix experiments. The presence of silicon dioxide allows for the investigation of the influence of higher Z material on the mixing characteristics.
Magnesium Ion Acts as a Signal for Capsule Induction in Cryptococcus neoformans
Rathore, Sudarshan S.; Raman, Thiagarajan; Ramakrishnan, Jayapradha
2016-01-01
Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF). To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C. neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C. neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C. neoformans and 37°C for Clinical C. neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C. neoformans. While investigating the individual components of artificial CSF, we found that Mg2+ ions influence the capsule growth in both environmental and clinical strains of C. neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60, and CAP64 in various capsule inducing media and in different concentrations of Mg2+ and Ca2+. Our results on gene expression suggest that, Mg2+ does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg2+ ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C. neoformans. PMID:27014245
Analysis of lomustine drug content in FDA-approved and compounded lomustine capsules.
KuKanich, Butch; Warner, Matt; Hahn, Kevin
2017-02-01
OBJECTIVE To determine the lomustine content (potency) in compounded and FDA-approved lomustine capsules. DESIGN Evaluation study. SAMPLE 2 formulations of lomustine capsules (low dose [7 to 11 mg] and high dose [40 to 48 mg]; 5 capsules/dose/source) from 3 compounders and from 1 manufacturer of FDA-approved capsules. PROCEDURES Lomustine content was measured by use of a validated high-pressure liquid chromatography method. An a priori acceptable range of 90% to 110% of the stated lomustine content was selected on the basis of US Pharmacopeia guidelines. RESULTS The measured amount of lomustine in all compounded capsules was less than the stated content (range, 59% to 95%) and was frequently outside the acceptable range (failure rate, 2/5 to 5/5). Coefficients of variation for lomustine content ranged from 4.1% to 16.7% for compounded low-dose capsules and from 1.1% to 10.8% for compounded high-dose capsules. The measured amount of lomustine in all FDA-approved capsules was slightly above the stated content (range, 104% to 110%) and consistently within the acceptable range. Coefficients of variation for lomustine content were 0.5% for low-dose and 2.3% for high-dose FDA-approved capsules. CONCLUSIONS AND CLINICAL RELEVANCE Compounded lomustine frequently did not contain the stated content of active drug and had a wider range of lomustine content variability than did the FDA-approved product. The sample size was small, and larger studies are needed to confirm these findings; however, we recommend that compounded veterinary formulations of lomustine not be used when appropriate doses can be achieved with FDA-approved capsules or combinations of FDA-approved capsules.
Koh, Eun S; Chung, Sun G; Kim, Tae Uk; Kim, Hee Chan
2012-12-01
To investigate whether capsule-preserving hydraulic distension with saline solution and corticosteroid for adhesive capsulitis induces biomechanical alterations in glenohumeral joint capsules along with clinical improvements. A case series. University outpatient clinic of physical medicine and rehabilitation. Eighteen patients with unilateral adhesive capsulitis. INTERVENTION AND MAIN OUTCOME MEASUREMENTS: Three hydraulic distensions with saline solution and corticosteroid were performed with 1-month intervals. To avoid rupturing capsules, all distensions were monitored by using real-time pressure-volume curves. Stiffness, maximal volume capacity, and pressure at the maximal volume capacity of the capsule were measured at each intervention. Clinical parameters, such as pain and range of motion, were recorded before, 3 days after, and 1 month after each distension. Stiffness decreased (47.6 ± 27.1 mm Hg/mL to 31.7 ± 18.4 mm Hg/mL to 24.2 ± 14.0 mm Hg/mL, mean SD) and maximal volume capacity increased (18.8 ± 7.3 mL to 20.5 ± 7.5 mL to 24.2 ± 7.0 mL, mean SD) significantly (P = .001 for both) at each repeated hydraulic distension. Pressure at the maximal volume capacity tended to decrease, but the decrements were not statistically significant (P = .662). The clinical parameters were significantly improved throughout and 1 month after the 3 repeat procedures (P < .05 for all). Capsule-preserving hydraulic distension changed the biomechanical properties of the glenohumeral joint capsule, lessening the stiffness and enlarging the volume capacity. These alterations were accompanied by improved range of motion and relief of pain. Repeated capsule-preserving hydraulic distension with saline solution and corticosteroid would be useful to treat adhesive capsulitis and to evaluate the treatment results. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Medical capsule robots: A renaissance for diagnostics, drug delivery and surgical treatment.
Mapara, Sanyat S; Patravale, Vandana B
2017-09-10
The advancements in electronics and the progress in nanotechnology have resulted in path breaking development that will transform the way diagnosis and treatment are carried out currently. This development is Medical Capsule Robots, which has emerged from the science fiction idea of robots travelling inside the body to diagnose and cure disorders. The first marketed capsule robot was a capsule endoscope developed to capture images of the gastrointestinal tract. Today, varieties of capsule endoscopes are available in the market. They are slightly larger than regular oral capsules, made up of a biocompatible case and have electronic circuitry and mechanisms to capture and transmit images. In addition, robots with diagnostic features such as in vivo body temperature detection and pH monitoring have also been launched in the market. However, a multi-functional unit that will diagnose and cure diseases inside the body has not yet been realized. A remote controlled capsule that will undertake drug delivery and surgical treatment has not been successfully launched in the market. High cost, inadequate power supply, lack of control over drug release, limited space for drug storage on the capsule, inadequate safety and no mechanisms for active locomotion and anchoring have prevented their entry in the market. The capsule robots can revolutionize the current way of diagnosis and treatment. This paper discusses in detail the applications of medical capsule robots in diagnostics, drug delivery and surgical treatment. In diagnostics, detailed analysis has been presented on wireless capsule endoscopes, issues associated with the marketed versions and their corresponding solutions in literature. Moreover, an assessment has been made of the existing state of remote controlled capsules for targeted drug delivery and surgical treatment and their future impact is predicted. Besides the need for multi-functional capsule robots and the areas for further research have also been highlighted. Copyright © 2017 Elsevier B.V. All rights reserved.
State diagram for adhesion dynamics of deformable capsules under shear flow.
Luo, Zheng Yuan; Bai, Bo Feng
2016-08-17
Due to the significance of understanding the underlying mechanisms of cell adhesion in biological processes and cell capture in biomedical applications, we numerically investigate the adhesion dynamics of deformable capsules under shear flow by using a three-dimensional computational fluid dynamic model. This model is based on the coupling of the front tracking-finite element method for elastic mechanics of the capsule membrane and the adhesion kinetics simulation for adhesive interactions between capsules and functionalized surfaces. Using this model, three distinct adhesion dynamic states are predicted, such as detachment, rolling and firm-adhesion. Specifically, the effects of capsule deformability quantified by the capillary number on the transitions of these three dynamic states are investigated by developing an adhesion dynamic state diagram for the first time. At low capillary numbers (e.g. Ca < 0.0075), whole-capsule deformation confers the capsule a flattened bottom in contact with the functionalized surface, which hence promotes the rolling-to-firm-adhesion transition. It is consistent with the observations from previous studies that cell deformation promotes the adhesion of cells lying in the rolling regime. However, it is surprising to find that, at relatively high capillary numbers (e.g. 0.0075 < Ca < 0.0175), the effect of capsule deformability on its adhesion dynamics is far more complex than just promoting adhesion. High deformability of capsules makes their bottom take a concave shape with no adhesion bond formation in the middle. The appearance of this specific capsule shape inhibits the transitions of both rolling-to-firm-adhesion and detachment-to-rolling, and it means that capsule deformation no longer promotes the capsule adhesion. Besides, it is interesting to note that, when the capillary number exceeds a critical value (e.g. Ca = 0.0175), the rolling state no longer appears, since capsules exhibit large deviation from the spherical shape.
21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium...
21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium...
21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium...
Månsson, Viktor; Gilsdorf, Janet R; Kahlmeter, Gunnar; Kilian, Mogens; Kroll, J Simon; Riesbeck, Kristian; Resman, Fredrik
2018-03-01
Encapsulated Haemophilus influenzae strains belong to type-specific genetic lineages. Reliable capsule typing requires PCR, but a more efficient method would be useful. We evaluated capsule typing by using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Isolates of all capsule types (a-f and nontypeable; n = 258) and isogenic capsule transformants (types a-d) were investigated. Principal component and biomarker analyses of mass spectra showed clustering, and mass peaks correlated with capsule type-specific genetic lineages. We used 31 selected isolates to construct a capsule typing database. Validation with the remaining isolates (n = 227) showed 100% sensitivity and 92.2% specificity for encapsulated strains (a-f; n = 61). Blinded validation of a supplemented database (n = 50) using clinical isolates (n = 126) showed 100% sensitivity and 100% specificity for encapsulated strains (b, e, and f; n = 28). MALDI-TOF mass spectrometry is an accurate method for capsule typing of H. influenzae.
Modeling microcapsules that communicate through nanoparticles to undergo self-propelled motion.
Usta, O Berk; Alexeev, Alexander; Zhu, Guangdong; Balazs, Anna C
2008-03-01
Using simulation and theory, we demonstrate how nanoparticles can be harnessed to regulate the interaction between two initially stationary microcapsules on a surface and promote the self-propelled motion of these capsules along the substrate. The first microcapsule, the "signaling" capsule, encases nanoparticles, which diffuse from the interior of this carrier and into the surrounding solution; the second capsule is the "target" capsule, which is initially devoid of particles. Nanoparticles released from the signaling capsule modify the underlying substrate and thereby initiate the motion of the target capsule. The latter motion activates hydrodynamic interactions, which trigger the signaling capsule to follow the target. The continued release of the nanoparticles sustains the motion of both capsules. In effect, the system constitutes a synthetic analogue of biological cell signaling and our findings can shed light on fundamental physical forces that control interactions between cells. Our findings can also yield guidelines for manipulating the interactions of synthetic microcapsules in microfluidic devices.
Polyelectrolyte multilayer capsules as vehicles with tunable permeability.
Antipov, Alexei A; Sukhorukov, Gleb B
2004-11-29
This review is devoted to a novel type of polymer micro- and nanocapsules. The shell of the capsule is fabricated by alternate adsorption of oppositely charged polyelectrolytes (PEs) onto the surface of colloidal particles. Cores of different nature (organic or inorganic) with size varied from 0.1 to 10 mum can be used for templating such PE capsules. The shell thickness can be tuned in nanometer range by assembling of defined number of PE layers. The permeability of capsules depends on the pH, ionic strength, solvent, polymer composition, and shell thickness; it can be controlled and varied over wide range of substances regarding their molecular weight and charge. Including functional polymers into capsule wall, such as weak PEs or thermosensitive polymers, makes the capsule permeability sensitive to correspondent external stimuli. Permeability of the capsules is of essential interest in diverse areas related to exploitation of systems with controlled and sustained release properties. The envisaged applications of such capsules/vesicles cover biotechnology, medicine, catalysis, food industry, etc.
Engineering multifunctional capsules through the assembly of metal-phenolic networks.
Guo, Junling; Ping, Yuan; Ejima, Hirotaka; Alt, Karen; Meissner, Mirko; Richardson, Joseph J; Yan, Yan; Peter, Karlheinz; von Elverfeldt, Dominik; Hagemeyer, Christoph E; Caruso, Frank
2014-05-26
Metal-organic coordination materials are of widespread interest because of the coupled benefits of inorganic and organic building blocks. These materials can be assembled into hollow capsules with a range of properties, which include selective permeability, enhanced mechanical/thermal stability, and stimuli-responsiveness. Previous studies have primarily focused on the assembly aspects of metal-coordination capsules; however, the engineering of metal-specific functionality for capsule design has not been explored. A library of functional metal-phenolic network (MPN) capsules prepared from a phenolic ligand (tannic acid) and a range of metals is reported. The properties of the MPN capsules are determined by the coordinated metals, allowing for control over film thickness, disassembly characteristics, and fluorescence behavior. Furthermore, the functional properties of the MPN capsules were tailored for drug delivery, positron emission tomography (PET), magnetic resonance imaging (MRI), and catalysis. The ability to incorporate multiple metals into MPN capsules demonstrates that a diverse range of functional materials can be generated. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Li, Xiaodong; Lu, Tian; Zhang, Jianxiang; Xu, Jiajie; Hu, Qiaoling; Zhao, Shifang; Shen, Jiacong
2009-07-01
"Micelle-enhanced" polyelectrolyte capsules were fabricated via a layer-by-layer technique, templated on hybrid calcium carbonate particles with built-in polymeric micelles based on polystyrene-b-poly(acrylic acid). Due to the presence of a large number of negatively charged micelles inside the polyelectrolyte capsule, which were liberated from templates, the capsule wall was reconstructed and had properties different to those of conventional polyelectrolyte capsules. This type of capsule could selectively entrap positively charged water-soluble substances. The encapsulation efficiency of positively charged substances was dependent on their molecular weight or size. For some positively charged compounds, such as rhodamine B and lysozyme, the concentration in the capsules was orders of magnitude higher than that in the incubation solution. In addition, in vitro release study suggested that the encapsulated compounds could be released through a sustained manner to a certain degree. All these results point to the fact that these capsules might be used as novel delivery systems for some water-soluble compounds.
Caunedo-Álvarez, Ángel; Romero-Vazquez, Javier; Herrerias-Gutierrez, Juan M
2008-01-01
Small bowel strictures can be missed by current diagnostic methods. The Patency capsule is a new non-endoscopic dissolvable capsule which has as an objective of checking the patency of digestive tract, in a non-invasive manner. The available clinical trials have demonstrated that the Patency© capsule is a good tool for assessment of the functional patency of the small bowel, and it allows identification of those patients who can safely undergo a capsule endoscopy, despite clinical and radiographic evidence of small-bowel obstruction. Some cases of intestinal occlusion have been reported with the Patency© capsule, four of them needed surgery. So, a new capsule with two timer plugs (Agile© capsule) has been recently developed in order to minimize the risk of occlusion. This new device stars its dissolution process earlier (30 h after ingestion) and its two timer plugs have been designed to begin the disintegration even when the device is blocked in a tight stricture. PMID:18785278
Cell cycle constraints on capsulation and bacteriophage susceptibility.
Ardissone, Silvia; Fumeaux, Coralie; Bergé, Matthieu; Beaussart, Audrey; Théraulaz, Laurence; Radhakrishnan, Sunish Kumar; Dufrêne, Yves F; Viollier, Patrick H
2014-11-25
Despite the crucial role of bacterial capsules in pathogenesis, it is still unknown if systemic cues such as the cell cycle can control capsule biogenesis. In this study, we show that the capsule of the synchronizable model bacterium Caulobacter crescentus is cell cycle regulated and we unearth a bacterial transglutaminase homolog, HvyA, as restriction factor that prevents capsulation in G1-phase cells. This capsule protects cells from infection by a generalized transducing Caulobacter phage (φCr30), and the loss of HvyA confers insensitivity towards φCr30. Control of capsulation during the cell cycle could serve as a simple means to prevent steric hindrance of flagellar motility or to ensure that phage-mediated genetic exchange happens before the onset of DNA replication. Moreover, the multi-layered regulatory circuitry directing HvyA expression to G1-phase is conserved during evolution, and HvyA orthologues from related Sinorhizobia can prevent capsulation in Caulobacter, indicating that alpha-proteobacteria have retained HvyA activity.
A locomotion mechanism with external magnetic guidance for active capsule endoscope.
Wang, Xiaona; Meng, Max Q H; Chen, Xijun
2010-01-01
Gastrointestinal (GI) disorder is one of the most common diseases in human body. The swallowable wireless capsule endoscopy has been proved to be a convenient, painless and effective way to examine the whole GI tract. However, lack of motion control makes the movement of the capsule substantially random, resulting in missing diagnosis. In this paper, a locomotion mechanism is developed for the next-generation active capsule endoscope. An internal actuator integrated on-board the capsule is designed to provide driving force and improve the dexterity. A small permanent magnet enclosed inside the capsule interacts with an external magnetic field to control the capsule's orientation and offer extra driving force. This mechanism avoids sophisticated and bulky control system and reduces power consumption inside the capsule. Ex-vivo experimental results showed that it can make a controllable movement inside the porcine large intestine. The mechanism also has the potential to be a platform for further development, such as devices of operations, spraying medicine, biopsy etc.
James, S L J; Connell, D A; O'Donnell, P; Saifuddin, A
2007-05-01
To describe the association of bone marrow oedema adjacent to areas of fibrocystic change at the femoral head and neck junction in patients with femoroacetabular impingement. The clinical and imaging findings in six patients with bone marrow oedema adjacent to an area of fibrocystic change at the femoral head and neck junction are presented. There were five males and one female (age range 19-42 years, mean age 34.5 years). Three patients were referred with a clinical suspicion of femoroacetabular impingement, two with suspected osteoid osteoma and one with a clinical diagnosis of sciatica. The volume of bone marrow oedema (grade 1: 0-25%, grade 2: 26-50%, grade 3: 51-75% and grade 4: 76-100% of the femoral neck width), presence of labral and articular cartilage abnormality, joint effusion, and femoral head and neck morphology were recorded. Magnetic resonance imaging (MRI) identified fibrocystic change in the anterolateral aspect of the femoral head and neck junction in all cases (mean size 9 mm, range 5-14 mm, three multilocular and three unilocular cysts). The volume of oedema was variable (one grade 1, two grade 2, one grade 3 and two grade 4). All patients had abnormality of the anterosuperior labrum with five patients demonstrating chondral loss. An abnormal femoral head and neck junction was identified in five patients. The radiological finding of fibrocystic change at the anterosuperior femoral neck with or without bone marrow oedema should prompt the search for femoroacetabular impingement. Bone marrow oedema may rarely be identified adjacent to these areas of cystic change and should be considered in the differential diagnosis of bone marrow oedema in the femoral neck.
A morphometric study of the human ear.
Alexander, K Skaria; Stott, David J; Sivakumar, Branavan; Kang, Norbert
2011-01-01
We examined variations in the shape of the human ear according to age, sex and ethnic group with particular attention to ear prominence. 420 volunteers were recruited. Measurements included; head height and length, ear height and axis, antihelix taken off angle, earlobe length and width, ear width at the helical root and tragus. Prominence was measured at the helical root and tragus (conchomastoid angle, conchal bowl depth and helical-mastoid distance). Good symmetry was shown for all measurements. Ethnically Indian volunteers had the largest ears (both length and width), followed by Caucasians, and Afro-Caribbeans. This trend was significant in males (p<0.001), but not significant in females (p=0.087). Ears increased in size throughout life. Subjectively, only 2% of volunteers felt their ears were prominent compared to 10% in the opinion of the principal investigator. No objective measurements were identified that accurately predicted subjective perceptions of prominence. We found consistent trends in ear morphology depending on ethnic group, age and sex. Our study was unable to define an objective method for assessing ear prominence. Decisions about what constitutes a prominent ear should be left to personal and aesthetic choice. Copyright © 2010 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Kostadinova, Aneta; Skirnisson, Karl
2007-11-01
Petasiger islandicus n. sp. is described and figured from a demographically isolated population of the horned grebe Podiceps auritus auritus (L.) in Lake Mývatn (Iceland). This new species belongs to the group of species with 19 collar spines which possess a large elongate-oval cirrus-sac, well-developed pars prostatica and massive bulb-like cirrus. Within this group, P. islandicus appears most similar to P. oschmarini Kostadinova & Gibson, 1998, a form with similar body dimensions described from the same host, but differs in having a larger head collar, collar spines, oral sucker, pharynx, testes and sucker-width ratio, and a smaller cirrus-sac, cirrus and eggs. Two Nearctic species resemble P. islandicus in general morphology but differ as follows: P. pseudoneocomense Bravo-Hollis, 1969 has a larger body and collar width, notably shorter collar spines, smaller testes and sucker-width ratio, and a shorter but much wider cirrus-sac which is also smaller relative to the ventral sucker and almost entirely anterior to it; and P. caribbensis Nassi, 1980 has a smaller body, shorter collar spines and a seminal vesicle which is small in relation to the cirrus-sac, vitelline fields reaching anteriorly to the level of the genital pore and the intestinal bifurcation is located more anteriorly.
Bhatt, Bhavik; Kumar, Vijay
2016-08-25
In this article, we describe a method to utilize cellulose dissolved in dimethyl sulfoxide and paraformaldehyde solvent system to fabricate two-piece regenerated cellulose hard shell capsules for their potential use as an oral controlled drug delivery a priori vehicle. A systematic evaluation of solution rheology as well as resulting capsule mechanical, visual and thermal analysis was performed to develop a suitable method to repeatedly fabricate RC hard shell capsule halves. Because of the viscoelastic nature of the cellulose solution, a combination of dip-coating and casting method, herein referred to as dip-casting method, was developed. The dip-casting method was formalized by utilizing two-stage 2(2) full factorial design approach in order to determine a suitable approach to fabricate capsules with minimal variability. Thermal annealing is responsible for imparting shape rigidity of the capsules. Proof-of-concept analysis for the utility of these capsules in controlled drug delivery was performed by evaluating the release of KCl from them as well as from commercially available USP equivalent formulations. Release of KCl from cellulose capsules was comparable to extended release capsule formulation. Copyright © 2016 Elsevier B.V. All rights reserved.
Chen, Feng-Jing; Etzler, Frank M; Ubben, Johanna; Birch, Amy; Zhong, Li; Schwabe, Robert; Dudhedia, Mayur S
2010-01-01
The present study investigated the effect of lipophilic components on the compatibility of propylene glycol (PG)-containing lipid-based drug delivery system (LBDDS) formulations with hard gelatin capsules. The presence of a lipophilic active pharmaceutical ingredient (API) (log P approximately 6.1) and an additional lipophilic excipient (Capmul MCM) significantly affected the activity of PG in the fills and the equilibrium of PG between capsule shells and fills. These changes in activity and equilibrium of PG were furthermore correlated to the mechanical and thermal properties of the liquid-filled capsules and subsequently linked to the shelf-life of the capsules on stability with respect to capsule deformation. The present study also investigated the mechanism by which lipophilic component(s) might affect the activity of PG in the fill formulations and the equilibrium of PG between capsule shells and fills. The activities of PG in two series of "binary" mixtures with Capmul MCM and with Cremophor EL were measured, respectively. The mixtures of PG containing Capmul MCM were found to be more nearly ideal than those containing Cremophor EL. The observed negative deviation from Rauolt's law indicates that the excess free energies of mixing are less then zero indicating favorable interaction between PG and the other component. It is speculated that enhanced hydrogen bonding opportunities with Cremophor EL are responsible for the decreased excess free energy of mixing. Replacement of Cremophor EL with lipophilic API also reduces the hydrogen bonding opportunities for PG in the mixtures. This hypothesis may further explain the increased activity of PG in the fills and the shifted equilibrium of PG toward the capsule shells. Activity determination utilizing headspace gas chromatography (GC) using short 30 min incubation time seems to be a time-efficient approach for assessing capsule-fill compatibility. Direct measurements of PG migration and other physical properties of the capsules took much longer time (7 weeks) for ranking the predicted capsule deformation at 40 degrees C. Asides from the time savings, activity determination can be considered to be material sparing by offering capsule-fill compatibility assessment even without the need for preparing liquid-filled capsules once appropriate positive and negative references are established. With further optimization, this approach should enable high throughput screening of LBDDS for capsule-fill compatibility in liquid-filled capsule development.
Sensor capsule for diagnosis of gastric disorders
NASA Technical Reports Server (NTRS)
Holen, J. T.
1972-01-01
Motility and pH sensor capsule is developed to monitor gastric acidity, pressure, and temperature. Capsule does not interfere with digestion. Sensor is capsule which includes pH electrode, Pitran pressure transducer, and thermistor temperature sensor all potted in epoxy and enclosed in high density polyethylene sheath.
NASA Astrophysics Data System (ADS)
Randall, J. J.; Booth, A. L.; Wooller, M. J.; Jones, B. M.; Gaglioti, B.
2012-12-01
Global surface air temperatures increased by ~0.74°C between 1906-2005, with average temperatures in the Arctic increasing at almost twice the rate as the rest of the planet. The Arctic Coastal Plain of Alaska is particularly susceptible and responsive to these fluctuations in climate. Better understanding both short- and long-term climate variability is important as this ecosystem provides food and habitat for hundreds of thousands of migratory birds and caribou. Despite the ecological importance of the Arctic Coastal Plain, relatively few studies exist that provide multi-proxy paleoclimatic data for the region and thus the rate at which climate and ecosystems have changed during the past century lack a longer term context. Here we present stable carbon and nitrogen isotope values from the analysis of bulk organic matter in samples from a ~6 m sediment core from Teshekpuk Lake, 80 miles southeast of Barrow, Alaska. AMS 14C dates on a nearby core indicate a basal age of ~15 kyr. The relatively low C/N values (mean <11) throughout the core infer that the organic matter is largely composed of autochthonous organic matter. Stable carbon isotope values from analyses of this organic material increase from ~-27‰ at the base of the core to peaks of ~-23‰ between ~10 and 8 kyr, inferring highs in lake production during this time. We also present stable oxygen isotope values from analyses of chironomid and aquatic invertebrate chitin preserved in the core. Non-biting midges in the family Chironomidae begin their lifecycles in freshwater. During their larval stages chironomids synthesize and molt chitinous head capsules. These head capsules record the oxygen isotopic composition of the lake water present at the time of synthesis, and are well preserved in lake sediments. These isotopic results are interpreted in terms of other recent isotope data from the north slope of Alaska in addition to a pollen reconstruction from the same core and their implications in terms of past environmental changes.
WE-G-BRD-08: End-To-End Targeting Accuracy of the Gamma Knife for Trigeminal Neuralgia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brezovich, I; Wu, X; Duan, J
2014-06-15
Purpose: Current QA procedures verify accuracy of individual equipment parameters, but may not include CT and MRI localizers. This study uses an end-to-end approach to measure the overall targeting errors in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 inch) diameter MRI contrast-filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the cavity position matches the Gamma Knife coordinates of 10 previously treated patients. Gafchromic EBT2 film is placed at the center of the cavity in coronal andmore » sagittal orientations. The films are marked with a pin prick to identify the cavity center. Treatments are planned for delivery with 4 mm collimators using MRI and CT scans acquired with the clinical localizer boxes and acquisition protocols. Coordinates of shots are chosen so that the cavity is centered within the 50% isodose volume. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pin prick and the centroid of the 50% isodose line. Results: Averaged over 10 patient simulations, targeting errors along the x, y and z coordinates (patient left-to-right, posterior-anterior, head-to-foot) were, respectively, −0.060 +/− 0.363, −0.350 +/− 0.253, and 0.364 +/− 0.191 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely 0.109 +/− 0.167, −0.191 +/− 0.144, and 0.211 +/− 0.94 mm. The largest errors in MRI and CT planned treatments were, respectively, y = −0.761 and x = 0.428 mm. Conclusion: Unless patient motion or stronger MRI image distortion in actual treatments caused additional errors, all patients received the prescribed dose, i.e., the targeted section of the trig±eminal nerve was contained within the 50% isodose surface in all cases.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aines, Roger D; Spadaccini, Christopher M; Stolaroff, Joshuah K
Method and apparatus for separating a target substance from a fluid or mixture. Capsules having a coating and stripping solvents encapsulated in the capsules are provided. The coating is permeable to the target substance. The capsules having a coating and stripping solvents encapsulated in the capsules are exposed to the fluid or mixture. The target substance migrates through the coating and is taken up by the stripping solvents. The target substance is separated from the fluid or mixture by driving off the target substance from the capsules.
Bowtle, William; Kanyowa, Lionel; Mackenzie, Mark; Higgins, Paul
2011-06-01
The industrial take-up of liquid-fill hard capsule technology is limited in part by lack of published long-term physical and chemical stability data which demonstrate the robustness of the system. To assess the effects of extreme long-term storage on liquid-fill capsule product quality and integrity, with respect to both the capsules per se and a standard blister-pack type (foil-film blister). Fourteen sets of stored peroxidation-sensitive liquid-fill hard gelatin capsule product samples, originating ~20 years from the current study, were examined with respect to physical and selected chemical properties, together with microbiological evaluation. All sets retained physical integrity of capsules and blister-packs. Capsules were free of leaks, gelatin cross-linking, and microbiological growth. Eight samples met a limit (anisidine value, 20) commonly used as an index of peroxidation for lipid-based products with shelf lives of 2-3 years. Foil-film blister-packs using PVC or PVC-PVdC as the thermoforming film were well-suited packaging components for the liquid-fill capsule format. The study confirms the long-term physical robustness of the liquid-fill hard capsule format, together with its manufacturing and banding processes. It also indicates that various peroxidation-sensitive products using the capsule format may be maintained satisfactorily over very prolonged storage periods.
[Exploring the clinical characters of Shugan Jieyu capsule through text mining].
Pu, Zheng-Ping; Xia, Jiang-Ming; Xie, Wei; He, Jin-Cai
2017-09-01
The study was main to explore the clinical characters of Shugan Jieyu capsule through text mining. The data sets of Shugan Jieyu capsule were downloaded from CMCC database by the method of literature retrieved from May 2009 to Jan 2016. Rules of Chinese medical patterns, diseases, symptoms and combination treatment were mined out by data slicing algorithm, and they were demonstrated in frequency tables and two dimension based network. Then totally 190 literature were recruited. The outcomess suggested that SC was most frequently correlated with liver Qi stagnation. Primary depression, depression due to brain disease, concomitant depression followed by physical diseases, concomitant depression followed by schizophrenia and functional dyspepsia were main diseases treated by Shugan Jieyu capsule. Symptoms like low mood, psychic anxiety, somatic anxiety and dysfunction of automatic nerve were mainy relieved bv Shugan Jieyu capsule.For combination treatment. Shugan Jieyu capsule was most commonly used with paroxetine, sertraline and fluoxetine. The research suggested that syndrome types and mining results of Shugan Jieyu capsule were almost the same as its instructions. Syndrome of malnutrition of heart spirit was the potential Chinese medical pattern of Shugan Jieyu capsule. Primary comorbid anxiety and depression, concomitant comorbid anxiety and depression followed by physical diseases, and postpartum depression were potential diseases treated by Shugan Jieyu capsule.For combination treatment, Shugan Jieyu capsule was most commonly used with paroxetine, sertraline and fluoxetine. Copyright© by the Chinese Pharmaceutical Association.
General route for the assembly of functional inorganic capsules.
Akartuna, Ilke; Tervoort, Elena; Studart, André R; Gauckler, Ludwig J
2009-11-03
Semipermeable, hollow capsules are attractive materials for the encapsulation and delivery of active agents in food processing, pharmaceutical and agricultural industries, and biomedicine. These capsules can be produced by forming a solid shell of close packed colloidal particles, typically polymeric particles, at the surface of emulsion droplets. However, current methods to prepare such capsules may involve multistep chemical procedures to tailor the surface chemistry of particles or are limited to particles that exhibit inherently the right hydrophobic-hydrophilic balance to adsorb around emulsion droplets. In this work, we describe a general and simple method to fabricate semipermeable, inorganic capsules from emulsion droplets stabilized by a wide variety of colloidal metal oxide particles. The assembly of particles at the oil-water interface is induced by the in situ hydrophobization of the particle surface through the adsorption of short amphiphilic molecules. The adsorption of particles at the interface leads to stable capsules comprising a single layer of particles in the outer shell. Such capsules can be used in the wet state or can be further processed into dry capsules. The permeability of the capsules can be modified by filling the interstices between the shell particles with polymeric or inorganic species. Functional capsules with biocompatible, bioresorbable, heat-resistant, chemical-resistant, and magnetic properties were prepared using alumina, silica, iron oxide, or tricalcium phosphate as particles in the shell.
Biomimetic/Bioinspired Design of Enzyme@capsule Nano/Microsystems.
Shi, J; Jiang, Y; Zhang, S; Yang, D; Jiang, Z
2016-01-01
Enzyme@capsule nano/microsystems, which refer to the enzyme-immobilized capsules, have received tremendous interest owing to the combination of the high catalytic activities of encapsulated enzymes and the hierarchical structure of the capsule. The preparation of capsules and simultaneous encapsulation of enzymes is recognized as the core process for the rational design and construction of enzyme@capsule nano/microsystems. The strategy used has three major steps: (a) generation of the templates, (b) surface coating on the templates, and (c) removal of the templates, and it has been proven to be effective and versatile for the construction of enzyme@capsule nano/microsystems. Several conventional methods, including layer-by-layer assembly of polyelectrolytes, liquid crystalline templating method, etc., were used to design and construct enzyme@capsule nano/microsystems, but these have two major drawbacks. One is the low mechanical stability of the systems and the second is the harsh conditions used in the construction process. Learning from nature, several biomimetic/bioinspired methods such as biomineralization, biomimetic/bioinspired adhesion, and their combination have been exploited for the construction of enzyme@capsule nano/microsystems. In this chapter, we will present a general protocol for the construction of enzyme@capsule nano/microsystems using the latter approach. Some suggestions for improved design, construction, and characterization will also be presented with detailed procedures for specific examples. © 2016 Elsevier Inc. All rights reserved.
Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Economic Analysis
Palimaka, S; Blackhouse, Gord; Goeree, Ron
2015-01-01
Background Small-bowel capsule endoscopy is a tool used to visualize the small bowel to identify the location of bleeds in obscure gastrointestinal bleeding (OGIB). Capsule endoscopy is currently funded in Ontario in cases where there has been a failure to identify a source of bleeding via conventional diagnostic procedures. In Ontario, capsule endoscopy is a diagnostic option for patients whose findings on esophagogastroduodenoscopy, colonoscopy, and push enteroscopy have been negative (i.e., the source of bleeding was not found). Objectives This economic analysis aims to estimate the budget impact of different rates of capsule endoscopy use as a complement to push enteroscopy procedures in patients aged 18 years and older. Data Sources Population-based administrative databases for Ontario were used to identify patients receiving push enteroscopy and small-bowel capsule endoscopy in the fiscal years 2008 to 2012. Review Methods A systematic literature search was performed to identify economic evaluations of capsule endoscopy for the investigation of OGIB. Studies were assessed for their methodological quality and their applicability to the Ontarian setting. An original budget impact analysis was performed using data from Ontarian administrative sources and published literature. The budget impact was estimated for different levels of use of capsule endoscopy as a complement to push enteroscopy due to the uncertain clinical utility of the capsule based on current clinical evidence. The analysis was conducted from the provincial public payer perspective. Results With varying rates of capsule endoscopy use, the budgetary impact spans from savings of $510,000,1 when no (0%) push enteroscopy procedures are complemented with capsule endoscopy, to $2,036,000, when all (100%) push enteroscopy procedures are complemented with capsule endoscopy. A scenario where 50% of push enteroscopy procedures are complemented with capsule endoscopy (expected use based on expert opinion) would result in additional expenditure of about $763,000. Limitations In the literature on OGIB, estimates of rebleeding rates after endoscopic procedures or spontaneous cessation rates are unreliable, with a lack of data. Rough estimates from expert consultation can provide an indication of expected additional use of capsule endoscopy; however, a wide range of capsule uses was explored. Conclusions The budgetary impact in the first year in Ontario of capsule endoscopy use to complement push enteroscopy procedures ranges from $510,000 in savings to an additional expenditure of $2,036,000 (at 0% and 100% push enteroscopy procedures complemented, respectively). The expected scenario of 50% of push enteroscopy procedures likely to benefit from the use of capsule endoscopy, based on expert opinion, would result in additional expenditures of $763,000 in the first year. PMID:26355732
Multidimensional Analysis of Direct-Drive Plastic-Shell Implosions on OMEGA
NASA Astrophysics Data System (ADS)
Radha, P. B.
2004-11-01
Direct-drive implosions of plastic shells with the OMEGA laser are used as energy-scaled warm surrogates for ignition cryogenic targets designed for use on the National Ignition Facility. Plastic targets involve varying shell thickness (15 to 33 μm), fill pressures (3 to 15 atm), and shell adiabats. The multidimensional hydrodynamics code DRACO is used to evaluate the effects of capsule-surface roughness and illumination nonuniformities on target performance. These simulations indicate that shell stability during the acceleration phase plays a critical role in determining fusion yields. For shells that are thick enough to survive the Rayleigh--Taylor growth, target yields are significantly reduced by growth of the long (ℓ < 10) and intermediate modes (20 < ℓ < 50) occurring from single-beam laser nonuniformities. The neutron production rate for these thick shells truncates relative to one-dimensional (1-D) predictions. The neutron-rate curves for the thinner shells, however, have significantly lower amplitudes and widths closer to 1-D results, indicating shell breakup during the acceleration phase. The simulation results are consistent with experimental observations. Previously, the stability of plastic-shell implosions had been correlated to a static ``mix-width'' at the boundary of the gas and plastic pusher estimated using a variety of experimental observables and an assumption of spherical symmetry. Results of these 2-D simulations provide a comprehensive understanding of warm-target implosion dynamics without assumptions of spherical symmetry and serve to answer the question of the hydrodynamic surrogacy between these plastic-shell implosions and the cryogenic ignition designs.
Mathews, Patrick D; Naldoni, Juliana; Adriano, Edson A
2017-12-01
A new species of Myxosporea, Henneguya loreotoensis n. sp. is described parasitizing the gill filaments from 17 of 35 specimens (48.5%) of Corydoras leucomelas (Siluriformes: Callichthyidae) caught in the Nanay River, near village Ninarumi, in the Loreto state, Peru. Mature spores were ellipsoidal in shape from the frontal view, measuring 36.2±0.1μm (36.1-36.3) in total length, 14.3±0.1μm (14.2-14.4) in body length, 5.1±0.1μm (4.9-5.3) in width and 21.9±0.1μm (21.8-22.0) in the caudal process. The two polar capsules were symmetrical and elongated, measuring 5.1±0.1μm (4.9-5.3) in length and 2.4±0.2μm (2.1-2.7) in width, containing a polar filament with five coils arranged obliquely to the longitudinal axis. The sporoplasm was binucleate. Partial sequencing of the ssu-rDNA of H. loretoensis n. sp. resulted in a total of 1676 nucleotides, and this sequence did not match any of the myxozoan available in the GenBank. The phylogenetic analysis shows H. loretoensis n. sp. as a sister species of Henneguya paraensis, another amazonian myxozoan parasite of Cichla temensis (Perciformes: Cichlidae). Copyright © 2017 Elsevier B.V. All rights reserved.
Kaur, Harpreet; Gupta, Aditya
2017-11-22
A new myxobolid, Thelohanellus pathankotensis parasitizing gill lamellae and caudal fins of the Indian minor carp Labeo dero has been described using light microscopy, histopathology and molecular analyses. The fish host was collected from a cold water wetland, Ranjit Sagar Wetland, Punjab, India located 32 ̊ 26 ̍ 30 ̎ N Latitude and 75 ̊ 43 ̍ 30 ̎ E Longitude. The prevalence of infection was 30%. The plasmodia were located in the gill lamellae and the caudal fins were cylindrical and whitish, 0.8-1.0 mm in size containing about 150-300 myxospores. The myxospores had a mean length of 9.70 ± 0.50 µm, width 3.85 ± 0.27 µm, mean length of polar capsule 3.0 ± 0.15 µm, width 2.68 ± 0.08 µm. The 18S rDNA nucleotide with 1098 bp of Thelohanellus pathankotensis n. sp. (accession number KU516661) clustered phylogenetically with other myxozoan parasites, with the species most closely related was T. sp. PBS- 2015 with 92% homogeneity and T. boggoti with 98% homogeneity. The intensity of infection or the mean abundance was determined by the gill plasmodial index (GPI) based on the number of countable plasmodia. The myxospores of the present species differed from others previously described infecting the hosts of family Cyprinidae, same tissue location and geographical location.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olson, R. E.; Leeper, R. J.
2013-09-27
The baseline DT ice layer inertial confinement fusion (ICF) ignition capsule design requires a hot spot convergence ratio of ~34 with a hot spot that is formed from DT mass originally residing in a very thin layer at the inner DT ice surface. In the present paper, we propose alternative ICF capsule designs in which the hot spot is formed mostly or entirely from mass originating within a spherical volume of DT vapor. Simulations of the implosion and hot spot formation in two DT liquid layer ICF capsule concepts—the DT wetted hydrocarbon (CH) foam concept and the “fast formed liquid”more » (FFL) concept—are described and compared to simulations of standard DT ice layer capsules. 1D simulations are used to compare the drive requirements, the optimal shock timing, the radial dependence of hot spot specific energy gain, and the hot spot convergence ratio in low vapor pressure (DT ice) and high vapor pressure (DT liquid) capsules. 2D simulations are used to compare the relative sensitivities to low-mode x-ray flux asymmetries in the DT ice and DT liquid capsules. It is found that the overall thermonuclear yields predicted for DT liquid layer capsules are less than yields predicted for DT ice layer capsules in simulations using comparable capsule size and absorbed energy. However, the wetted foam and FFL designs allow for flexibility in hot spot convergence ratio through the adjustment of the initial cryogenic capsule temperature and, hence, DT vapor density, with a potentially improved robustness to low-mode x-ray flux asymmetry.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olson, R. E.; Leeper, R. J.
2013-09-15
The baseline DT ice layer inertial confinement fusion (ICF) ignition capsule design requires a hot spot convergence ratio of ∼34 with a hot spot that is formed from DT mass originally residing in a very thin layer at the inner DT ice surface. In the present paper, we propose alternative ICF capsule designs in which the hot spot is formed mostly or entirely from mass originating within a spherical volume of DT vapor. Simulations of the implosion and hot spot formation in two DT liquid layer ICF capsule concepts—the DT wetted hydrocarbon (CH) foam concept and the “fast formed liquid”more » (FFL) concept—are described and compared to simulations of standard DT ice layer capsules. 1D simulations are used to compare the drive requirements, the optimal shock timing, the radial dependence of hot spot specific energy gain, and the hot spot convergence ratio in low vapor pressure (DT ice) and high vapor pressure (DT liquid) capsules. 2D simulations are used to compare the relative sensitivities to low-mode x-ray flux asymmetries in the DT ice and DT liquid capsules. It is found that the overall thermonuclear yields predicted for DT liquid layer capsules are less than yields predicted for DT ice layer capsules in simulations using comparable capsule size and absorbed energy. However, the wetted foam and FFL designs allow for flexibility in hot spot convergence ratio through the adjustment of the initial cryogenic capsule temperature and, hence, DT vapor density, with a potentially improved robustness to low-mode x-ray flux asymmetry.« less
Atay, Orhan; Mahajan, Lori; Kay, Marsha; Mohr, Franziska; Kaplan, Barbara; Wyllie, Robert
2009-08-01
Capsule retention is a potential complication of capsule endoscopy (CE). The aims of our study were to determine the incidence of capsule retention in pediatric patients undergoing CE and to identify potential risk factors for capsule retention. We performed an institutional review board-approved retrospective chart review of pediatric patients undergoing CE studies at a single center. Data collected included patient age, sex, prior diagnosis of inflammatory bowel disease (IBD), CE indication, prior small bowel series results, study result, and complications. Two hundred seven CE procedures were performed in pediatric patients during the study period. Capsule retention occurred in 3 (1.4%) of the 207 studies. All 3 patients had known Crohn disease (CD). The risk of capsule retention in pediatric patients with known IBD was 5.2% (3/58). The risk of capsule retention for patients with suspected IBD and all other indications was 0%. If small bowel disease was identified on upper gastrointestinal series in patients with known CD, then the risk of capsule retention was 37.5% (3/8). Only 7 patients with known IBD had a body mass index (BMI) below the 5th percentile. Of these 7 patients, 3 (43%) had capsule retention. Red flags for potential CE retention identified in our study include known IBD (5.2% retention risk), previous small bowel follow-through demonstrating small bowel CD (37.5% retention risk), and BMI <5th percentile with known IBD (43% retention risk). Caution is advised in these pediatric patients before capsule ingestion.
The Anterolateral Capsule of the Knee Behaves Like a Sheet of Fibrous Tissue.
Guenther, Daniel; Rahnemai-Azar, Amir A; Bell, Kevin M; Irarrázaval, Sebastián; Fu, Freddie H; Musahl, Volker; Debski, Richard E
2017-03-01
The function of the anterolateral capsule of the knee has not been clearly defined. However, the contribution of this region of the capsule to knee stability in comparison with other anterolateral structures can be determined by the relative force that each structure carries during loading of the knee. Purpose/Hypothesis: The purpose of this study was to determine the forces in the anterolateral structures of the intact and anterior cruciate ligament (ACL)-deficient knee in response to an anterior tibial load and internal tibial torque. It was hypothesized that the anterolateral capsule would not function like a traditional ligament (ie, transmitting forces only along its longitudinal axis). Controlled laboratory study. Loads (134-N anterior tibial load and 7-N·m internal tibial torque) were applied continuously during flexion to 7 fresh-frozen cadaveric knees in the intact and ACL-deficient state using a robotic testing system. The lateral collateral ligament (LCL) and the anterolateral capsule were separated from the surrounding tissue and from each other. This was done by performing 3 vertical incisions: lateral to the LCL, medial to the LCL, and lateral to the Gerdy tubercle. Attachments of the LCL and anterolateral capsule were detached from the underlying tissue (ie, meniscus), leaving the insertions and origins intact. The force distribution in the anterolateral capsule, ACL, and LCL was then determined at 30°, 60°, and 90° of knee flexion using the principle of superposition. In the intact knee, the force in the ACL in response to an anterior tibial load was greater than that in the other structures ( P < .001). However, in response to an internal tibial torque, no significant differences were found between the ACL, LCL, and forces transmitted between each region of the anterolateral capsule after capsule separation. The anterolateral capsule experienced smaller forces (~50% less) compared with the other structures ( P = .048). For the ACL-deficient knee in response to an anterior tibial load, the force transmitted between each region of the anterolateral capsule was 434% greater than was the force in the anterolateral capsule ( P < .001) and 54% greater than the force in the LCL ( P = .036) at 30° of flexion. In response to an internal tibial torque at 30°, 60°, or 90° of knee flexion, no significant differences were found between the force transmitted between each region of the anterolateral capsule and the LCL. The force in the anterolateral capsule was significantly smaller than that in the other structures at all knee flexion angles for both loading conditions ( P = .004 for anterior tibial load and P = .04 for internal tibial torque). The anterolateral capsule carries negligible forces in the longitudinal direction, and the forces transmitted between regions of the capsule were similar to the forces carried by the other structures at the knee, suggesting that it does not function as a traditional ligament. Thus, the anterolateral capsule should be considered a sheet of tissue. Surgical repair techniques for the anterolateral capsule should restore the ability of the tissue to transmit forces between adjacent regions of the capsule rather than along its longitudinal axis.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-23
...] Determination That INTAL (cromolyn sodium) Inhalation Capsule, 20 Milligrams, Was Not Withdrawn From Sale for... Food and Drug Administration (FDA) has determined that INTAL (cromolyn sodium) Inhalation Capsule, 20... allow FDA to approve abbreviated new drug applications (ANDAs) for cromolyn sodium inhalation capsule...
Mercury Capsule Separation Tests
1960-04-01
Mercury capsule separation from Redstone booster in the Altitude Wind Tunnel (AWT): NASA Lewis conducted full-scale separation tests of the posigrade rockets that were fired after the Redstone rockets burned out. The researchers studied the effect of the posigrade rockets firing on the Redstone booster and retrograde package. This film shows the Mercury capsule being mounted to the Redstone missile model in the Altitude Wind Tunnel. The capsule's engines are fired and it horizontally separates from the Atlas. After firing the capsule swings from an overhead crane.
Strosberg, Jonathan R; Shibata, David; Kvols, Larry K
2007-01-01
A 43-year-old man with a history of metastatic carcinoid disease is presented. The patient had symptoms of chronic intermittent abdominal pain two years after undergoing a wireless capsule endoscopy procedure. Radiological examinations revealed a retained capsule endoscope, and the patient underwent exploratory laparotomy with capsule retrieval. To the authors’ knowledge, this is the first case presentation of chronic, partial small bowel obstruction caused by unrecognized retention of a capsule endoscope. PMID:17299616
A New Species of Microhyla (Anura: Microhylidae) from Nilphamari, Bangladesh
Howlader, Mohammad Sajid Ali; Nair, Abhilash; Gopalan, Sujith V.; Merilä, Juha
2015-01-01
A new species of Microhyla frog from the Nilphamari district of Bangladesh is described and compared with its morphologically similar and geographically proximate congeners. Molecular phylogeny derived from mitochondrial DNA sequences revealed that although the new species – designated here as Microhyla nilphamariensis sp. nov. – forms a clade with M. ornate, it is highly divergent from M. ornata and all of its congeners, with 5.7 – 13.2% sequence divergence at the 16S rRNA gene. The new species can be identified phenotypically on the basis of a set of diagnostic (both qualitative and quantitative) characters as follows: head length is 77% of head width, distance from front of eyes to the nostril is roughly six times greater than nostril–snout length, internarial distance is roughly five times greater than nostril–snout length, interorbital distance is two times greater than internarial distance, and distance from back of mandible to back of the eye is 15% of head length. Furthermore, inner metacarpal tubercle is small and ovoid-shaped, whereas outer metacarpal tubercle is very small and rounded. Toes have rudimentary webbing, digital discs are absent, inner metatarsal tubercle is small and round, outer metatarsal tubercle is ovoid-shaped, minute, and indistinct. PMID:25806804
NASA Astrophysics Data System (ADS)
Matsushita, Daisuke; Okuma, Kusuo; Watanabe, Satoshi; Furukawa, Akinori
A ducted Darrieus-type hydro turbine has been proposed for extra-low head hydropower utilization of total head less than 2m, where development is almost not done in the commercial base. Though the efficiency of Darrieus-type turbine, which is cross flow type, is not so high as conventional type, the Darrieus-type has a cost-advantage due to the simple structure. By installing a narrow intake at upstream of the runner, the efficiency becomes higher than normal intake that a width of which is the same as one of runner section. In the case of normal intake, the casing clearance between the runner pitch circle and the side-wall at the runner section becomes the influential factor which deteriorates the efficiency. On the other hand, in the case of narrow intake, it is possible to keep efficiency high, based on the fact that the distorting flow to the clearance is prevented. In the present paper, the effects of narrow intake and draft tube on turbine performance are experimentally examined and the design guideline of simplified structure for ducted Darrieus-type turbine with narrow intake is proposed.
Mazza, Giuseppe; Paoli, Francesco; Strangi, Agostino; Torrini, Giulia; Marianelli, Leonardo; Peverieri, Giuseppino Sabbatini; Binazzi, Francesco; Bosio, Giovanni; Sacchi, Stefano; Benvenuti, Claudia; Venanzio, Davide; Giacometto, Emanuela; Roversi, Pio F; Poinar, George O
2017-10-01
A new species of mermithid nematode, Hexamermis popilliae n. sp. (Nematoda: Mermithidae) is described from the Japanese beetle Popillia japonica Newman in Italy, an area of new introduction for this invasive pest. The combination of the following characters separates H. popilliae from other members of the genus Hexamermis Steiner, 1924: adult head obtuse; amphidial pouches slightly posterior to lateral head papillae in female but adjacent to lateral head papillae in males; amphidial openings large, well developed; amphidial pouches elliptical in females and oblong in males; cuticular vulvar cone well developed, vulvar lips greatly reduced or lacking, vagina curved at tip where meeting uteri, without reverse bend (not S-shaped), spicules slightly curved, with a slight bend in the basal portion, approximately equal to body width at cloaca. This is the first record of a species of Hexamermis parasitizing the Japanese beetle Popillia japonica. The only previous mention of mermithid nematodes from P. japonica was an undescribed species of Psammomermis in North America. Hexamermis popilliae will be evaluated as a potential biological control agent in an integrated control program of the Japanese beetle in Italy.
Leake, S.A.; Lilly, M.R.
1995-01-01
The Fairbanks, Alaska, area has many contaminated sites in a shallow alluvial aquifer. A ground-water flow model is being developed using the MODFLOW finite-difference ground-water flow model program with the River Package. The modeled area is discretized in the horizontal dimensions into 118 rows and 158 columns of approximately 150-meter square cells. The fine grid spacing has the advantage of providing needed detail at the contaminated sites and surface-water features that bound the aquifer. However, the fine spacing of cells adds difficulty to simulating interaction between the aquifer and the large, braided Tanana River. In particular, the assignment of a river head is difficult if cells are much smaller than the river width. This was solved by developing a procedure for interpolating and extrapolating river head using a river distance function. Another problem is that future transient simulations would require excessive numbers of input records using the current version of the River Package. The proposed solution to this problem is to modify the River Package to linearly interpolate river head for time steps within each stress period, thereby reducing the number of stress periods required.
Seat and seatbelt accommodation in fire apparatus: Anthropometric aspects.
Hsiao, Hongwei; Whitestone, Jennifer; Wilbur, Michael; Lackore, J Roger; Routley, J Gordon
2015-11-01
This study developed anthropometric information on U.S. firefighters to guide fire-apparatus seat and seatbelt designs and future standards development. A stratified sample of 863 male and 88 female firefighters across the U.S. participated in the study. The study results suggested 498 mm in width, 404 mm in depth, and 365-476 mm in height for seat pans; 429-522 mm in width and 542 mm in height for seat back; 871 mm in height for head support; a seat space of 733 mm at shoulder and 678 mm at hip; and a knee/leg clearance of 909 mm in fire truck cab. Also, 1520 mm of lap belt web effective length and 2828 mm of lap-and-shoulder belt web effective length were suggested. These data for fire-truck seats and seatbelts provide a foundation for fire apparatus manufacturers and standards committees to improve firefighter seat designs and seatbelt usage compliance. Published by Elsevier Ltd.
Sarı, Ahmet; Alkan, Cemil; Biçer, Alper
2016-05-01
In this study, PMMA/heneicosane (C21) and PMMA/octacosane (C28) micro-nano capsules were fabricated via emulsion polymerisation method. The chemical structures of the fabricated capsules were verified with the FT-IR spectroscopy analysis. The results of POM, SEM and PSD analysis indicated that most of the capsules were consisted of micro/nano-sized spheres with compact surface. The DSC measurements showed that the capsules had melting temperature in the range of about 39-60 °C and latent heat energy storage capacity in the range of about 138-152 J/g. The results of TGA showed that sublimit temperature values regarding the first degradation steps of both capsules were quite over the phase change or working temperatures of encapsulated paraffins. The thermal cycling test exhibited that the capsules had good thermal reliability and chemical stability. Additionally, the prepared capsules had reasonably high thermal conductivity.
The Antiphagocytic Activity of SeM of Streptococcus equi Requires Capsule.
Timoney, John F; Suther, Pranav; Velineni, Sridhar; Artiushin, Sergey C
2014-01-01
Resistance to phagocytosis is a crucial virulence property of Streptococcus equi (Streptococcus equi subsp. equi; Se), the cause of equine strangles. The contribution and interdependence of capsule and SeM to killing in equine blood and neutrophils were investigated in naturally occurring strains of Se. Strains CF32, SF463 were capsule and SeM positive, strains Lex90, Lex93 were capsule negative and SeM positive and strains Se19, Se1-8 were capsule positive and SeM deficient. Phagocytosis and killing of Se19, Se1-8, Lex90 and Lex93 in equine blood and by neutrophils suspended in serum were significantly (P ≤ 0.02) greater compared to CF32 and SF463. The results indicate capsule and SeM are both required for resistance to phagocytosis and killing and that the anti-phagocytic property of SeM is greatly reduced in the absence of capsule.
Capsule-odometer: a concept to improve accurate lesion localisation.
Karargyris, Alexandros; Koulaouzidis, Anastasios
2013-09-21
In order to improve lesion localisation in small-bowel capsule endoscopy, a modified capsule design has been proposed incorporating localisation and - in theory - stabilization capabilities. The proposed design consists of a capsule fitted with protruding wheels attached to a spring-mechanism. This would act as a miniature odometer, leading to more accurate lesion localization information in relation to the onset of the investigation (spring expansion e.g., pyloric opening). Furthermore, this capsule could allow stabilization of the recorded video as any erratic, non-forward movement through the gut is minimised. Three-dimensional (3-D) printing technology was used to build a capsule prototype. Thereafter, miniature wheels were also 3-D printed and mounted on a spring which was attached to conventional capsule endoscopes for the purpose of this proof-of-concept experiment. In vitro and ex vivo experiments with porcine small-bowel are presented herein. Further experiments have been scheduled.
Abang, Sariah; Chan, Eng-Seng; Poncelet, Denis
2012-01-01
The objective of this study was to investigate the effects of process variables on the encapsulation of oil in a calcium alginate membrane using an inverse gelation technique. A dispersion of calcium chloride solution in sunflower oil (water-in-oil emulsion) was added dropwise to the alginate solution. The migration of calcium ions to the alginate solution initiates the formation of a ca-alginate membrane around the emulsion droplets. The membrane thickness of wet capsules and the elastic modulus of dry capsules increased following first-order kinetics with an increasing curing time. An increase in the calcium chloride concentration increased the membrane thickness of wet capsules and the elastic modulus of dry capsules. An increase in the alginate concentration decreased the mean diameter of wet capsules but increased the elastic modulus of dry capsules.
Li, Xiaodong; Li, Xiaohui; Zhang, Jianxiang; Zhao, Shifang; Shen, Jiacong
2008-06-01
Novel "micelles enhanced" polyelectrolyte (PE) capsules based on functional templates of hybrid calcium carbonate were fabricated. Evidences suggested that the structure of capsule wall was different from that of conventional PE capsules, and the wall permeability of these PE capsules changed significantly. Lysozyme, a positively charged protein in neutral solution, was studied as a model protein to be encapsulated into the "micelles enhanced" PE capsules. Confocal laser scanning microscope was used to observe the entrapping process in real time, while UV-Vis spectroscope and scanning force microscope measurements suggested the high efficiency of encapsulation. In addition, the fluorescence recovery after photobleaching technique was employed to determine the existence form of deposited molecules. Further studies showed even negatively charged water-soluble peptides or proteins can be encapsulated into these hybrid capsules by modulating the pH value in bulk solution under its isoelectronic point as well. Copyright 2007 Wiley Periodicals, Inc.
Stopping mechanism for capsule endoscope using electrical stimulus.
Woo, Sang Hyo; Kim, Tae Wan; Cho, Jin Ho
2010-01-01
An ingestible capsule, which has the ability to stop at certain locations in the small intestine, was designed and implemented to monitor intestinal diseases. The proposed capsule can contract the small intestine by using electrical stimuli; this contraction causes the capsule to stop when the maximum static frictional force (MSFF) is larger than the force of natural peristalsis. In vitro experiments were carried out to verify the feasibility of the capsule, and the results showed that the capsule was successfully stopped in the small intestine. Various electrodes and electrical stimulus parameters were determined on the basis of the MSFF. A moderate increment of the MSFF (12.7 +/- 4.6 gf at 5 V, 10 Hz, and 5 ms) and the maximum increment of the MSFF (56.5 +/- 9.77 gf at 20 V, 10 Hz, and 5 ms) were obtained, and it is sufficient force to stop the capsule.
Wireless Insufflation of the Gastrointestinal Tract
Battaglia, Santina; Smith, Byron F.; Ciuti, Gastone; Gerding, Jason; Menciassi, Arianna; Obstein, Keith L.; Valdastri, Pietro; Webster, Robert J.
2013-01-01
Despite clear patient experience advantages, low specificity rates have thus far prevented swallowable capsule endoscopes from replacing traditional endoscopy for diagnosis of colon disease. One explanation for this is that capsule endoscopes lack the ability to provide insufflation, which traditional endoscopes use to distend the intestine for a clear view of the internal wall. To provide a means of insufflation from a wireless capsule platform, in this paper we use biocompatible effervescent chemical reactions to convert liquids and powders carried onboard a capsule into gas. We experimentally evaluate the quantity of gas needed to enhance capsule visualization and locomotion, and determine how much gas can be generated from a given volume of reactants. These experiments motivate the design of a wireless insufflation capsule, which is evaluated in ex vivo experiments. These experiments illustrate the feasibility of enhancing visualization and locomotion of endoscopic capsules through wireless insufflation. PMID:23212312
Wireless communication link for capsule endoscope at 600 MHz.
Khaleghi, A; Balasingham, I
2015-01-01
Simulation of a wireless communication link for a capsule endoscopy is presented for monitoring of small intestine in humans. The realized communication link includes the transmitting capsule antenna, the outside body receiving antenna and the model of the human body. The capsule antenna is designed for operating at the frequency band of 600 MHz with an impedance bandwidth of 10 MHz and omnidirectional radiation pattern. The quality of the communication link is improved by using directive antenna outside body inside matching layer for electromagnetic wave tuning to the body. The outside body antenna has circular polarization that guaranteeing the communication link for different orientations of the capsule inside intestine. It is shown that the path loss for the capsule in 60 mm from the abdomen surface varies between 37-47 dB in relation to the antenna orientation. This link can establish high data rate wireless communications for capsule endoscopy.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-14
...] Determination That VESANOID (Tretinoin) Capsules, 10 Milligrams, Were Not Withdrawn From Sale for Reasons of... Drug Administration (FDA) has determined that VESANOID (tretinoin) Capsules, 10 milligrams (mg), were... approved. FDA may not approve an ANDA that does not refer to a listed drug. VESANOID (tretinoin) Capsules...
21 CFR 872.3110 - Dental amalgam capsule.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...
21 CFR 872.3110 - Dental amalgam capsule.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...
21 CFR 872.3110 - Dental amalgam capsule.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...
21 CFR 872.3110 - Dental amalgam capsule.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...
21 CFR 872.3110 - Dental amalgam capsule.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...
1959-09-01
An Atlas launch vehicle carrying the Big Joe capsule leaves its launching pad on a 2,000-mile ballistic flight to the altitude of 100 miles. The Big Joe capsule is a boilerplate model of the marned orbital capsule under NASA's Project Mercury. The capsule was recovered and studied for the effect of re-entry heat and other flight stresses.
21 CFR 520.260 - n-Butyl chloride capsules.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false n-Butyl chloride capsules. 520.260 Section 520.260... DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.260 n-Butyl chloride capsules. (a)(1) Specifications. n-Butyl chloride capsules, veterinary contain 272 milligrams or 816 milligrams...
Les Habitats: Culture Capsules in English for Use in Beginning French Classes.
ERIC Educational Resources Information Center
Hofts, Jan; And Others
Eight culture capsules describing various aspects of French housing are presented. Each capsule includes a French-American contrast and gives ideas for classroom presentation and student activities. The capsules deal with: le logement, les immeubles, les exterieurs, la minuterie, les portes, la salle de bain, le refrigerateur, and culture grains…
Dimitrakopoulos, P; Kuriakose, S
2015-04-14
Determination of the elastic properties of the membrane of artificial capsules is essential for the better design of the various devices that are utilized in their engineering and biomedical applications. However this task is complicated owing to the combined effects of the shear and area-dilatation moduli on the capsule deformation. Based on computational investigation, we propose a new methodology to determine a membrane's shear modulus, independent of its area-dilatation modulus, by flowing strain-hardening capsules in a converging micro-capillary of comparable size under Stokes flow conditions, and comparing the experimental measurements of the capsule elongation overshooting with computational data. The capsule prestress, if any, can also be determined with the same methodology. The elongation overshooting is practically independent of the viscosity ratio for low and moderate viscosity ratios, and thus a wide range of capsule fluids can be employed. Our proposed experimental device can be readily produced via glass fabrication while owing to the continuous flow in the micro-capillary, the characterization of a large number of artificial capsules is possible.
Multi-methodological investigation of the variability of the microstructure of HPMC hard capsules.
Faulhammer, E; Kovalcik, A; Wahl, V; Markl, D; Stelzer, F; Lawrence, S; Khinast, J G; Paudel, A
2016-09-25
The objective of this study was to analyze differences in the subtle microstructure of three different grades of HMPC hard capsule shells using mechanical, spectroscopic, microscopic and tomographic approaches. Dynamic mechanical analysis (DMA), thermogravimetric analysis (TGA), vibrational spectroscopic, X-Ray scattering techniques as well as environmental scanning electron microscopy (ESEM) and optical coherence tomography (OCT) were used. Two HPMC capsules manufactured via chemical gelling, one capsule shell manufactured via thermal gelling and one thermally gelled transparent capsule were included. Characteristic micro-structural alterations (associated manufacturing processes) such as mechanical and physical properties relevant to capsule performance and processability were thoroughly elucidated with the integration of data obtained from multi-methodological investigations. The physico-chemical and physico-mechanical data obtained from a gamut of techniques implied that thermally gelled HPMC hard capsule shells could offer an advantage in terms of machinability during capsule filling, owing to their superior micro- and macroscopic structure as well as specifically the mechanical stability under dry or humid conditions. Copyright © 2016 Elsevier B.V. All rights reserved.
Emerging Issues and Future Developments in Capsule Endoscopy
Slawinski, Piotr R.; Obstein, Keith L.; Valdastri, Pietro
2015-01-01
Capsule endoscopy (CE) has transformed from a research venture into a widely used clinical tool and the primary means for diagnosing small bowel pathology. These orally administered capsules traverse passively through the gastrointestinal tract via peristalsis and are used in the esophagus, stomach, small bowel, and colon. The primary focus of CE research in recent years has been enabling active CE manipulation and extension of the technology to therapeutic functionality; thus, widening the scope of the procedure. This review outlines clinical standards of the technology as well as recent advances in CE research. Clinical capsule applications are discussed with respect to each portion of the gastrointestinal tract. Promising research efforts are presented with an emphasis on enabling active capsule locomotion. The presented studies suggest, in particular, that the most viable solution for active capsule manipulation is actuation of a capsule via exterior permanent magnet held by a robot. Developing capsule procedures adhering to current healthcare standards, such as enabling a tool channel or irrigation in a therapeutic device, is a vital phase in the adaptation of CE in the clinical setting. PMID:26028956
NASA Astrophysics Data System (ADS)
Shibata, A.; Nakano, J.; Ohmi, M.; Kawamata, K.; Nakagawa, T.; Tsukada, T.
2012-03-01
To simulate irradiation assisted stress corrosion cracking (IASCC) behavior by in-pile experiments, it is necessary to irradiate specimens up to a neutron fluence that is higher than the IASCC threshold fluence. Pre-irradiated specimens must be relocated from pre-irradiation capsules to in-pile capsules. Hence, a remote welding machine has been developed. And the integrity of capsule housing for a long term irradiation was evaluated by tensile tests in air and slow strain rate tests in water. Two type specimens were prepared. Specimens were obtained from the outer tubes of capsule irradiated to 1.0-3.9 × 1026 n/m2 (E > 1 MeV). And specimens were irradiated in a leaky capsule to 0.03-1.0 × 1026 n/m2. Elongation more than 15% in tensile test at 423 K was confirmed and no IGSCC fraction was shown in SSRT at 423 K which was estimated as temperature at the outer tubes of the capsule under irradiation.
Cell cycle constraints on capsulation and bacteriophage susceptibility
Ardissone, Silvia; Fumeaux, Coralie; Bergé, Matthieu; Beaussart, Audrey; Théraulaz, Laurence; Radhakrishnan, Sunish Kumar; Dufrêne, Yves F; Viollier, Patrick H
2014-01-01
Despite the crucial role of bacterial capsules in pathogenesis, it is still unknown if systemic cues such as the cell cycle can control capsule biogenesis. In this study, we show that the capsule of the synchronizable model bacterium Caulobacter crescentus is cell cycle regulated and we unearth a bacterial transglutaminase homolog, HvyA, as restriction factor that prevents capsulation in G1-phase cells. This capsule protects cells from infection by a generalized transducing Caulobacter phage (φCr30), and the loss of HvyA confers insensitivity towards φCr30. Control of capsulation during the cell cycle could serve as a simple means to prevent steric hindrance of flagellar motility or to ensure that phage-mediated genetic exchange happens before the onset of DNA replication. Moreover, the multi-layered regulatory circuitry directing HvyA expression to G1-phase is conserved during evolution, and HvyA orthologues from related Sinorhizobia can prevent capsulation in Caulobacter, indicating that alpha-proteobacteria have retained HvyA activity. DOI: http://dx.doi.org/10.7554/eLife.03587.001 PMID:25421297
Malakar, Jadupati; Datta, Prabir Kumar; Purakayastha, Saikat Das; Dey, Sanjay; Nayak, Amit Kumar
2014-03-01
The present study deals with the development and evaluations of stomach-specific floating capsules containing salbutamol sulfate-loaded oil-entrapped alginate-based beads. Salbutamol sulfate-loaded oil-entrapped beads were prepared and capsulated within hard gelatin capsules (size 1). The effects of HPMC K4M and potato starch weight masses on drug encapsulation efficiency (DEE) of beads and cumulative drug release at 10h (R10 h) from capsules was analyzed by 3(2) factorial design. The optimization results indicate increasing of DEE in the oil-entrapped beads and decreasing R10 h from capsules with increment of HPMC K4M and potato starch weight masses. The optimized formulation showed DEE of 70.02 ± 3.16% and R10 h of 56.96 ± 2.92%. These capsules showed floatation over 6h and sustained drug release over 10h in gastric pH (1.2). In vivo X-ray imaging study of optimized floating capsules in rabbits showed stomach-specific gastroretention over a prolonged period. Copyright © 2013 Elsevier B.V. All rights reserved.
Inadvertent trypan blue posterior capsule staining during cataract surgery.
Burkholder, Bryn M; Srikumaran, Divya; Nanji, Afshan; Lee, Bryan; Weinberg, Robert S
2013-04-01
To report 5 cases of inadvertent posterior capsule staining with trypan blue during phacoemulsification. Retrospective, observational case series. Five cases of posterior capsule staining with trypan blue were identified from cataract surgeries performed at an academic institution. All 5 eyes underwent phacoemulsification with use of iris retractors. The surgical videos from each case were reviewed to better understand the mechanisms and risk factors for posterior capsule staining with trypan blue and techniques to avoid this complication. No eyes had clinical evidence of zonular pathology during their preoperative examination. Only 1 patient reported a possible childhood history of trauma to both eyes. One eye had uveitis, requiring posterior synechialysis. All 5 cases involved the use of iris retractors. No other intraoperative complications occurred, and the intraocular lens was successfully placed in the capsular bag in all cases. All eyes had resolution of posterior capsule staining by postoperative day 8. Inadvertent posterior capsule staining with trypan blue can occur in eyes that appear structurally normal. The use of iris retractors may facilitate posterior capsule staining by allowing the posterior flow of trypan blue under the iris and through the zonules to the posterior capsule. Surgeons should consider techniques to minimize the risk of posterior capsule staining, particularly in cases involving the use of iris retractors. Copyright © 2013 Elsevier Inc. All rights reserved.
Kurayama, Fumio; Suzuki, Satoru; Oyamada, Tetsuro; Furusawa, Takeshi; Sato, Masahide; Suzuki, Noboru
2010-09-01
A new and facile method for preparing microcapsules with 3-aminopropyltriethoxysilane (APTES)/alginate hybrid shell (AP-capsule) is proposed based on gelling and sol-gel processes. In this method, conventional capsules with alginate shells (Alg-capsule) are produced by dripping carboxymethyl cellulose solution containing calcium chloride into a sodium alginate solution. Subsequently, addition of the Alg-capsules to an aqueous APTES solution induces the formation of APTES/alginate hybrid shells. The optical observation shows that the texture of AP-capsules is more glossy and transparent than that of Alg-capsules. The surface morphology and elemental composition of microcapsules were characterized by Scanning Electron Microscopy (SEM), Fourier Transform Infrared Spectroscopy (FT-IR) and X-ray Photoelectron Spectroscopy (XPS). The results suggest that APTES molecules are incorporated to the framework of the alginate shells via electrostatic interaction between amino groups of APTES and carboxyl groups of alginate and the hybrid shells have a dense and homogeneous structure. In the formation reaction, the shrinking of the capsule shells occurs and the accumulation of APTES in the capsule shells proceeds with pseudo first-order kinetics. Moreover, these behaviors are greatly influenced by pH of the reaction solution, especially promoted under acidic and alkaline conditions. Copyright 2010 Elsevier Inc. All rights reserved.
Angelova, N; Hunkeler, D
2001-01-01
Capsules were obtained by interpolymer complexation between chitosan (polycation) and sodium hexametaphosphate (SMP, oligoanion). The effect of the preparation conditions on the capsule characteristics was evaluated. Specifically, the influence of variables such as pH, ionic strength, reagent concentration, and additives on the capsule permeability properties was investigated using dextran as a model permeant. The capsule membrane permeability was found to increase by decreasing the chitosan/SMP ratio as well as adding mannitol to the oligoanion recipient bath. Increasing the ionic strength or the pH of the initial chitosan solution was also found to enhance the membrane permeability, moving the membrane exclusion limit to higher values. Generally, the capsules prepared tinder all tested conditions had a relatively low permeability which rarely exceeded a molecular cut-off of 40 kD based on dextran standards. Furthermore, the diffusion rate showed a strong temporal dependence, indicating that the capsules prepared under various conditions exhibit different apparent pore size densities on the surface. The results indicated that, in order to obtain the desired capsule mass-transfer properties, the preparation conditions should be carefully considered and adjusted. Adding a polyol as well as low salt amount (less than 0.15%) is preferable as a means of modulating the diffusion characteristics, without disturbing the capsule mechanical stability.
Behara, Srinivas R.B.; Farkas, Dale R.; Hindle, Michael; Longest, P. Worth
2013-01-01
Purpose The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. Methods DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. Results The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. Conclusions High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD < 1.5 µm, FPF<5µm/ED > 90%, and ED > 80%. PMID:23949304
Hydrocolloid liquid-core capsules for the removal of heavy-metal cations from water.
Nussinovitch, A; Dagan, O
2015-12-15
Liquid-core capsules with a non-crosslinked alginate fluidic core surrounded by a gellan membrane were produced in a single step to investigate their ability to adsorb heavy metal cations. The liquid-core gellan-alginate capsules, produced by dropping alginate solution with magnesium cations into gellan solution, were extremely efficient at adsorbing lead cations (267 mg Pb(2+)/g dry alginate) at 25 °C and pH 5.5. However, these capsules were very weak and brittle, and an external strengthening capsule was added by using magnesium cations. The membrane was then thinned with the surfactant lecithin, producing capsules with better adsorption attributes (316 mg Pb(+2)/g dry alginate vs. 267 mg Pb(+2)/g dry alginate without lecithin), most likely due to the thinner membrane and enhanced mass transfer. The capsules' ability to adsorb other heavy-metal cations - copper (Cu(2+)), cadmium (Cd(2+)) and nickel (Ni(2+)) - was tested. Adsorption efficiencies were 219, 197 and 65 mg/g, respectively, and were correlated with the cation's affinity to alginate. Capsules with the sorbed heavy metals were regenerated by placing in a 1M nitric acid suspension for 24h. Capsules could undergo three regeneration cycles before becoming damaged. Copyright © 2015 Elsevier B.V. All rights reserved.
Alginate/sodium caseinate aqueous-core capsules: a pH-responsive matrix.
Ben Messaoud, Ghazi; Sánchez-González, Laura; Jacquot, Adrien; Probst, Laurent; Desobry, Stéphane
2015-02-15
Alginate capsules have several applications. Their functionality depends considerably on their permeability, chemical and mechanical stability. Consequently, the creation of composite system by addition of further components is expected to control mechanical and release properties of alginate capsules. Alginate and alginate-sodium caseinate composite liquid-core capsules were prepared by a simple extrusion. The influence of the preparation pH and sodium caseinate concentration on capsules physico-chemical properties was investigated. Results showed that sodium caseinate influenced significantly capsules properties. As regards to the membrane mechanical stability, composite capsules prepared at pH below the isoelectric point of sodium caseinate exhibited the highest surface Young's modulus, increasing with protein content, explained by potential electrostatic interactions between sodium caseinate amino-groups and alginate carboxylic group. The kinetic of cochineal red A release changed significantly for composite capsules and showed a pH-responsive release. Sodium caseinate-dye mixture studied by absorbance and fluorescence spectroscopy confirmed complex formation at pH 2 by electrostatic interactions between sodium caseinate tryptophan residues and cochineal red sulfonate-groups. Consequently, the release mechanism was explained by membrane adsorption process. This global approach is useful to control release mechanism from macro and micro-capsules by incorporating guest molecules which can interact with the entrapped molecule under specific conditions. Copyright © 2014 Elsevier Inc. All rights reserved.
Primate lens capsule elasticity assessed using Atomic Force Microscopy
Ziebarth, Noël M.; Arrieta, Esdras; Feuer, William J.; Moy, Vincent T.; Manns, Fabrice; Parel, Jean-Marie
2011-01-01
The purpose of this project is to measure the elasticity of the human and non-human primate lens capsule at the microscopic scale using Atomic Force Microscopy (AFM). Elasticity measurements were performed using AFM on the excised anterior lens capsule from 9 cynomolgus monkey (5.9–8.0 years), 8 hamadryas baboon (2.8–10.1 years), and 18 human lenses (33–79 years). Anterior capsule specimens were obtained by performing a 5mm continuous curvilinear capsulorhexis and collecting the resulting disk of capsular tissue. To remove the lens epithelial cells the specimen was soaked in 0.1% trypsin and 0.02% EDTA for five minutes, washed, and placed on a Petri dish and immersed in DMEM. Elasticity measurements of the capsule were performed with a laboratory-built AFM system custom designed for force measurements of ophthalmic tissues. The capsular specimens were probed with an AFM cantilever tip to produce force-indentation curves for each specimen. Young’s modulus was calculated from the force-indentation curves using the model of Sneddon for a conical indenter. Young’s modulus of elasticity was 20.1–131kPa for the human lens capsule, 9.19–117kPa for the cynomolgus lens capsule, and 13.1–62.4kPa for the baboon lens capsule. Young’s modulus increased significantly with age in humans (p=0.03). The age range of the monkey and baboon samples was not sufficient to justify an analysis of age dependence. The capsule elasticity of young humans (<45 years) was not statistically different from that of the monkey and baboon. In humans, there is an increase in lens capsule stiffness at the microscale that could be responsible for an increase in lens capsule bulk stiffness. PMID:21420953
Colucci, Philippe; D'Angelo, Pina; Mautone, Giuseppe; Scarsi, Claudia; Ducharme, Murray P
2011-06-01
To assess the pharmacokinetic equivalence of a new soft capsule formulation of levothyroxine versus a marketed reference product and to assess the soft capsule formulated with stricter potency guidelines versus the capsule before the implementation of the new potency rule. Two single-dose randomized two-way crossover pharmacokinetic equivalence studies and one dosage form proportionality single-dose study comparing low, medium, and high strengths of the new formulation. All three studies were performed in a clinical setting. Participants were healthy male and female adult subjects with normal levothyroxine levels. A total of 90 subjects participated in the three studies. Pharmacokinetic parameters were calculated on baseline- adjusted concentrations. The first pharmacokinetic equivalence study compared the levothyroxine sodium soft capsule formulation (Tirosint) with the reference Synthroid tablets and the two products were considered bioequivalent. The dosage form proportionality study compared the 50-, 100-, and 150-μg test capsules strengths dosed at the same level (600 μg) and all three strengths were considered equivalent when given at the same dosage. The last study compared the test capsule used in the first two studies with a new capsule formulation following the new potency guideline (±5%) set forward by the Food and Drug Administration and the two capsules were considered bioequivalent. Doses were well tolerated by subjects in all three studies with no serious adverse events reported. The levothyroxine soft capsule formulated with the stricter new potency guideline set forward by the Food and Drug Administration met equivalence criteria in terms of rate and extent of exposure under fasting conditions to the reference tablet formulation. Clinical doses of the capsule formulation can be given using any combination of the commercialized strengths.
Oshika, T.; Nagata, T.; Ishii, Y.
1998-01-01
AIMS—To investigate the adhesion characteristics of several intraocular lenses (IOLs) to the simulated and rabbit lens capsule. METHODS—Adhesive force to bovine collagen sheets was measured in water with polymethylmethacrylate (PMMA), three piece silicone, and acrylic foldable IOLs. In rabbit eyes, phacoemulsification and IOL implantation were performed. Three weeks later, adhesion between the anterior/posterior capsules and IOL optic was tested, and the capsule was examined histologically. RESULTS—The mean adhesive force to the collagen sheet was 1697 (SD 286) mg for acrylic foldable, 583 (49) mg for PMMA, and 0 mg for silicone IOLs (p=0.0003, Kruskal-Wallis test). Scores (0-5) of adhesion between rabbit anterior capsule and IOL optic were 4.50 (0.55) for acrylic foldable, 3.20 (0.84) for PMMA, and 0.40 (0.55) for silicone IOLs (p=0.004). Scores between rabbit posterior capsule and IOL optic displayed a similar tendency; 4.50 (0.84) for acrylic foldable, 3.00 (1.00) for PMMA, and 0.40 (0.55) for silicone IOLs (p=0.021). Histological observation indicated that the edge of IOL optic suppressed the migration of lens epithelial cells towards the centre of the posterior capsule. This inhibitory effect was most pronounced with acrylic foldable IOL and least with silicone IOL. CONCLUSIONS—The acrylic foldable IOL adhered to the lens capsule more than the PMMA IOL, and the silicone IOL showed no adhesiveness. These differences seem to play a role in preventing lens epithelial cells from migrating and forming posterior capsule opacification. Keywords: intraocular lens; lens capsule; posterior capsule opacification; adhesion PMID:9713064
Polski, Andrzej; Iwaniak, Karol; Kasperek, Regina; Modrzewska, Joanna; Sobótka-Polska, Karolina; Sławińska, Karolina; Poleszak, Ewa
2015-01-01
The capsule is one of the most important solid dosage forms in the pharmaceutical industry. It is easier and faster to produce than a tablet, because it requires fewer excipients. Generally, capsules are easy to swallow and mask any unpleasant taste of the substances used while their release profiles can be easily modified. Papaverine hydrochloride was used as a model substance to show different release profiles using different excipients. The main aim of the study was to analyze the impact of using different polymers on the release profile of papaverine hydrochloride from hard gelatin capsules. Six series of hard gelatin capsules containing papaverine hydrochloride as a model drug and different excipients were made. Then, the angle of repose, flow rate, mass flow rate and volume flow rate of the powders used for capsule production were analyzed. The uniform weight and disintegration time of the capsules were studied. The dissolution study was performed in a basket apparatus, while the amount of papaverine hydrochloride released was determined spectrophotometrically at 251 nm. Only one formula of powder had satisfactory flow properties, while all formulas had good Hausner ratios. The best properties were from powder containing polyvinylpyrrolidone 10k. The disintegration time of capsules varied from 1:30 min to 2:00 min. As required by Polish Pharmacopoeia X, 80% of the active substance in all cases was released within 15 minutes. The capsules with polyvinylpyrrolidone 10k were characterized by the longest release. On the other hand, capsules containing microcrystalline cellulose had the fastest release profile. Using 10% of different polymers, without changing the other excipients, had a significant impact on the physical properties of the powders and papaverine hydrochloride release profile. The two most preferred capsule formulations contained either polyvinylpyrrolidone 10k or microcrystalline cellulose.
Haines, Brian M.; Yi, S. A.; Olson, R. E.; ...
2017-07-10
The wetted foam capsule design for inertial confinement fusion capsules, which includes a foam layer wetted with deuterium-tritium liquid, enables layered capsule implosions with a wide range of hot-spot convergence ratios (CR) on the National Ignition Facility. In this paper, we present a full-scale wetted foam capsule design that demonstrates high gain in one-dimensional simulations. In these simulations, increasing the convergence ratio leads to an improved capsule yield due to higher hot-spot temperatures and increased fuel areal density. High-resolution two-dimensional simulations of this design are presented with detailed and well resolved models for the capsule fill tube, support tent, surfacemore » roughness, and predicted asymmetries in the x-ray drive. Our modeling of these asymmetries is validated by comparisons with available experimental data. In 2D simulations of the full-scale wetted foam capsule design, jetting caused by the fill tube is prevented by the expansion of the tungsten-doped shell layer due to preheat. While the impacts of surface roughness and predicted asymmetries in the x-ray drive are enhanced by convergence effects, likely underpredicted in 2D at high CR, simulations predict that the capsule is robust to these features. Nevertheless, the design is highly susceptible to the effects of the capsule support tent, which negates all of the one-dimensional benefits of increasing the convergence ratio. Indeed, when the support tent is included in simulations, the yield decreases as the convergence ratio is increased for CR > 20. Finally and nevertheless, the results suggest that the full-scale wetted foam design has the potential to outperform ice layer capsules given currently achievable levels of asymmetries when fielded at low convergence ratios (CR < 20).« less
Rukke, H V; Engen, S A; Schenck, K; Petersen, F C
2016-08-01
Streptococcus mitis is a colonizer of the oral cavity and the nasopharynx, and is closely related to Streptococcus pneumoniae. Both species occur in encapsulated and unencapsulated forms, but in S. mitis the role of the capsule in host interactions is mostly unknown. Therefore, the aim of this study was to examine how capsule expression in S. mitis can modulate interactions with the host with relevance for colonization. The S. mitis type strain, as well as two mutants of the type strain, an isogenic capsule deletion mutant, and a capsule switch mutant expressing the serotype 4 capsule of S. pneumoniae TIGR4, were used. Wild-type and capsule deletion strains of S. pneumoniae TIGR4 were included for comparison. We found that capsule production in S. mitis reduced adhesion to oral and lung epithelial cells. Further, exposure of oral epithelial cells to encapsulated S. mitis resulted in higher interleukin-6 and CXCL-8 transcription levels relative to the unencapsulated mutant. Capsule expression in S. mitis increased the sensitivity to human neutrophil peptide 1-3 but reduced the sensitivity to human β-defensin-3 and cathelicidin. This was in contrast with S. pneumoniae in which capsule expression has been generally associated with increased sensitivity to human antimicrobial peptides (AMPs). Collectively, these findings indicate that capsule expression in S. mitis is important in modulating interactions with epithelial cells, and is associated with increased or reduced susceptibility to AMPs depending on the nature of the AMP. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Spada, C; Spera, G; Riccioni, M; Biancone, L; Petruzziello, L; Tringali, A; Familiari, P; Marchese, M; Onder, G; Mutignani, M; Perri, V; Petruzziello, C; Pallone, F; Costamagna, G
2005-09-01
The current visualization of small-bowel strictures using traditional radiological methods is associated with high radiation doses and false-negative results. These methods do not always reveal small-bowel patency for solids. The aim is to assess the safety of the Given patency system and its ability to detect intestinal strictures in patients with strictures that are known or suspected radiologically. The Given patency capsule is composed of lactose, remains intact in the gastrointestinal tract for 40-100 hours post ingestion, and disintegrates thereafter. A total of 34 patients with small-bowel stricture were prospectively enrolled; 30 had a previous diagnosis of Crohn's disease, three had adhesion syndrome and in one ischemic enteritis was suspected. Of the patients, 15 (44.1 %) had previously undergone surgery. Following ingestion, the capsule was monitored for integrity and transit time, using a specially designed Given scanner and also radiologically. Seventeen patients had been enrolled with the intent of using the patency capsule as a preliminary test in patients with small-bowel strictures before undergoing video capsule endoscopy. 30 patients (88.2 %) retrieved the capsule in the stool; it was intact in 20 (median transit time 22 hours), and disintegrated in 10 patients (median transit time 53 hours). Six patients complained of abdominal pain which disappeared within 24 hours. The scanner successfully indicated the presence of the capsule in 94 % of cases. Ten patients underwent video capsule endoscopy following the patency capsule examination; in all of these the video capsule passed through the small-bowel stricture. This feasibility study has shown that the Given patency capsule is a safe, effective, and convenient tool for assessment of functional patency of the small bowel. It can indicate functional patency even in cases where traditional radiology indicates stricture.
Application of Bio-digestion for Capsule Gelatin-- From the Pharmaceutical Wastes to the Manure
NASA Astrophysics Data System (ADS)
Pan, C.; Huang, S.; Chang, Y.; Wen, J.
2013-12-01
The purpose of this study was to bio-digest the capsule gelatin from the waste of pharmaceutical processes such as cutting and stamping for capsule shells producing. We screened soil bacterial flora for capsule gelatin biolysis, and found the most competent one named Yuntech-7. A 15% (w/w) of capsule gelatin could fully digested by Yuntech-7 for 3 days growth with an N-limited medium in a 37°C incubator. In order to recycle and reuse the gelatin waste, the different percentages of capsule gelatin were co-composted with the vegetable residues to produce manure in an anaerobic fermentation by an extra Yuntech-7 inoculation. After 14 days incubation, we collected the filtrate to examine the contents of N, P, and K. The data shows that the P and K keep the same value by roughly between the blank and the control sets, but the total N values were approximately a 5-fold increase in 20% and a 10-fold increase in 40% of capsule gelatin integrated. We suggested that the capsule gelatin was majorly decomposed by Yuntech-7, because the total N value was no observable change in the capsule gelatin and vegetable residues co-compost with a Yuntech-7-free condition. We also performed some field tests using the capsule gelatin generated liquid manure, and the preliminary test shows the plants got great benefits on culture size and in environmental resistance. In conclusion, the process in bio-digestion of waste capsule gelatin by soil bacteria, Yuntech-7, was produced a valuable manure not only aliment the plants but also complement the soil bacterial populations.
Stability of dronabinol capsules when stored frozen, refrigerated, or at room temperature.
Wempe, Michael F; Oldland, Alan; Stolpman, Nancy; Kiser, Tyree H
2016-07-15
Results of a study to determine the 90-day stability of dronabinol capsules stored under various temperature conditions are reported. High-performance liquid chromatography (HPLC) with ultraviolet (UV) detection was used to assess the stability of dronabinol capsules (synthetic delta-9-tetrahydrocannabinol [Δ9-THC] mixed with high-grade sesame oil and other inactive ingredients and encapsulated as soft gelatin capsules) that were frozen, refrigerated, or kept at room temperature for three months. The dronabinol capsules remained in the original foil-sealed blister packs until preparation for HPLC-UV assessment. The primary endpoint was the percentage of the initial Δ9-THC concentration remaining at multiple designated time points. The secondary aim was to perform forced-degradation studies under acidic conditions to demonstrate that the HPLC-UV method used was stability indicating. The appearance of the dronabinol capsules remained unaltered during frozen, cold, or room-temperature storage. Regardless of storage condition, the percentage of the initial Δ9-THC content remaining was greater than 97% for all evaluated samples at all time points over the three-month study. These experimental data indicate that the product packaging and the sesame oil used to formulate dronabinol capsules efficiently protect Δ9-THC from oxidative degradation to cannabinol; this suggests that pharmacies can store dronabinol capsules in nonrefrigerated automated dispensing systems, with a capsule expiration date of 90 days after removal from the refrigerator. Dronabinol capsules may be stored at room temperature in their original packaging for up to three months without compromising capsule appearance and with minimal reduction in Δ9-THC concentration. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Sami, Haider; Maparu, Auhin K; Kumar, Ashok; Sivakumar, Sri
2012-01-01
Towards the goal of development of a generic nanomaterial delivery system and delivery of the 'as prepared' nanoparticles without 'further surface modification' in a generic way, we have fabricated a hybrid polymer capsule as a delivery vehicle in which nanoparticles are loaded within their cavity. To this end, a generic approach to prepare nanomaterials-loaded polyelectrolyte multilayered (PEM) capsules has been reported, where polystyrene sulfonate (PSS)/polyallylamine hydrochloride (PAH) polymer capsules were employed as nano/microreactors to synthesize variety of nanomaterials (metal nanoparticles; lanthanide doped inorganic nanoparticles; gadolinium based nanoparticles, cadmium based nanoparticles; different shapes of nanoparticles; co-loading of two types of nanoparticles) in their hollow cavity. These nanoparticles-loaded capsules were employed to demonstrate generic delivery of payload of nanoparticles intracellularly (HeLa cells), without the need of individual nanoparticle surface modification. Validation of intracellular internalization of nanoparticles-loaded capsules by HeLa cells was ascertained by confocal laser scanning microscopy. The green emission from Tb(3+) was observed after internalization of LaF(3):Tb(3+)(5%) nanoparticles-loaded capsules by HeLa cells, which suggests that nanoparticles in hybrid capsules retain their functionality within the cells. In vitro cytotoxicity studies of these nanoparticles-loaded capsules showed less/no cytotoxicity in comparison to blank capsules or untreated cells, thus offering a way of evading direct contact of nanoparticles with cells because of the presence of biocompatible polymeric shell of capsules. The proposed hybrid delivery system can be potentially developed to avoid a series of biological barriers and deliver multiple cargoes (both simultaneous and individual delivery) without the need of individual cargo design/modification.
Sami, Haider; Maparu, Auhin K.; Kumar, Ashok; Sivakumar, Sri
2012-01-01
Towards the goal of development of a generic nanomaterial delivery system and delivery of the ‘as prepared’ nanoparticles without ‘further surface modification’ in a generic way, we have fabricated a hybrid polymer capsule as a delivery vehicle in which nanoparticles are loaded within their cavity. To this end, a generic approach to prepare nanomaterials-loaded polyelectrolyte multilayered (PEM) capsules has been reported, where polystyrene sulfonate (PSS)/polyallylamine hydrochloride (PAH) polymer capsules were employed as nano/microreactors to synthesize variety of nanomaterials (metal nanoparticles; lanthanide doped inorganic nanoparticles; gadolinium based nanoparticles, cadmium based nanoparticles; different shapes of nanoparticles; co-loading of two types of nanoparticles) in their hollow cavity. These nanoparticles-loaded capsules were employed to demonstrate generic delivery of payload of nanoparticles intracellularly (HeLa cells), without the need of individual nanoparticle surface modification. Validation of intracellular internalization of nanoparticles-loaded capsules by HeLa cells was ascertained by confocal laser scanning microscopy. The green emission from Tb3+ was observed after internalization of LaF3:Tb3+(5%) nanoparticles-loaded capsules by HeLa cells, which suggests that nanoparticles in hybrid capsules retain their functionality within the cells. In vitro cytotoxicity studies of these nanoparticles-loaded capsules showed less/no cytotoxicity in comparison to blank capsules or untreated cells, thus offering a way of evading direct contact of nanoparticles with cells because of the presence of biocompatible polymeric shell of capsules. The proposed hybrid delivery system can be potentially developed to avoid a series of biological barriers and deliver multiple cargoes (both simultaneous and individual delivery) without the need of individual cargo design/modification. PMID:22649489
NASA Astrophysics Data System (ADS)
Haines, Brian M.; Yi, S. A.; Olson, R. E.; Khan, S. F.; Kyrala, G. A.; Zylstra, A. B.; Bradley, P. A.; Peterson, R. R.; Kline, J. L.; Leeper, R. J.; Shah, R. C.
2017-07-01
The wetted foam capsule design for inertial confinement fusion capsules, which includes a foam layer wetted with deuterium-tritium liquid, enables layered capsule implosions with a wide range of hot-spot convergence ratios (CR) on the National Ignition Facility. We present a full-scale wetted foam capsule design that demonstrates high gain in one-dimensional simulations. In these simulations, increasing the convergence ratio leads to an improved capsule yield due to higher hot-spot temperatures and increased fuel areal density. High-resolution two-dimensional simulations of this design are presented with detailed and well resolved models for the capsule fill tube, support tent, surface roughness, and predicted asymmetries in the x-ray drive. Our modeling of these asymmetries is validated by comparisons with available experimental data. In 2D simulations of the full-scale wetted foam capsule design, jetting caused by the fill tube is prevented by the expansion of the tungsten-doped shell layer due to preheat. While the impacts of surface roughness and predicted asymmetries in the x-ray drive are enhanced by convergence effects, likely underpredicted in 2D at high CR, simulations predict that the capsule is robust to these features. Nevertheless, the design is highly susceptible to the effects of the capsule support tent, which negates all of the one-dimensional benefits of increasing the convergence ratio. Indeed, when the support tent is included in simulations, the yield decreases as the convergence ratio is increased for CR > 20. Nevertheless, the results suggest that the full-scale wetted foam design has the potential to outperform ice layer capsules given currently achievable levels of asymmetries when fielded at low convergence ratios (CR < 20).
Geno, K. Aaron; Hauser, Jocelyn R.; Gupta, Kanupriya
2014-01-01
Streptococcus pneumoniae produces a protective capsular polysaccharide whose production must be modulated for bacterial survival within various host niches. Capsule production is affected in part by a phosphoregulatory system comprised of CpsB, CpsC, and CpsD. Here, we found that growth of serotype 2 strain D39 under conditions of increased oxygen availability resulted in decreased capsule levels concurrent with an ∼5-fold increase in Cps2B-mediated phosphatase activity. The change in Cps2B phosphatase activity did not result from alterations in the levels of either the cps2B transcript or the Cps2B protein. Recombinant Cps2B expressed in Escherichia coli similarly exhibited increased phosphatase activity under conditions of high-oxygen growth. S. pneumoniae D39 derivatives with defined deletion or point mutations in cps2B demonstrated reduced phosphatase activity with corresponding increases in levels of Cps2D tyrosine phosphorylation. There was, however, no correlation between these phenotypes and the level of capsule production. During growth under reduced-oxygen conditions, the Cps2B protein was essential for parental levels of capsule, but phosphatase activity alone could be eliminated without an effect on capsule. Under increased-oxygen conditions, deletion of cps2B did not affect capsule levels. These results indicate that neither Cps2B phosphatase activity nor Cps2D phosphorylation levels per se are determinants of capsule levels, whereas the Cps2B protein is important for capsule production during growth under conditions of reduced but not enhanced oxygen availability. Roles for factors outside the capsule locus, possible interactions between capsule regulatory proteins, and links to other cellular processes are also suggested by the results described in this study. PMID:24659769
El Massik, M A; Abdallah, O Y; Galal, S; Daabis, N A
2003-05-01
Seven semisolid fill bases were selected for the formulation of 24 capsule formulations, each containing 100 mg of phenytoin sodium. The fill materials were selected based on the water absorption capacity of their mixtures with phenytoin sodium. The fill matrices included lipophilic bases (castor oil, soya oil, and Gelucire (G) 33/01), amphiphilic bases (G 44/14 and Suppocire BP), and water-soluble bases (PEG 4000 and PEG 6000). The drug:base ratio was 1:2. Excipients such as lecithin, docusate sodium, and poloxamer 188 were added to some formulations. The dissolution rate study indicated that formulations containing lipophilic and amphiphilic bases showed the best release profiles. These are F4 (castor oil-1% docusate sodium); F10 (castor oil-3% poloxamer 188); F14 (G33/01-10% lecithin); F17 (G33/01-1% docusate sodium), and F20 (Suppocire BP). Further, the dissolution stability of the five formulations above was assessed by an accelerated stability study at 30 degrees C and 75% RH using standard Epanutin capsules for comparison. The study included the test and standard capsules either packed in the container of marketed Epanutin capsules (packed) or removed from their outer pack (unpacked). Release data indicated superior release rates of castor oil based formulations (F4 and F10) relative to standard capsules in both the unpacked and packed forms. For instance, the extent of drug release at 30 min after 1 month was 91% for F4 and F10 and 20% for standard capsules. Drug release from packed capsules after 6 months storage was 88% for both formulations F4 and F10 and 35% for standard capsules. In conclusion, the pharmaceutical quality of phenytoin sodium capsules can be improved by using a semisolid lipophilic matrix filled in hard gelatin capsules.
Prevalence and risk factors of adhesive capsulitis of the shoulder after breast cancer treatment.
Yang, Seoyon; Park, Dae Hwan; Ahn, Sei Hyun; Kim, Jisun; Lee, Jong Won; Han, Jun Young; Kim, Dong Kyu; Jeon, Jae Yong; Choi, Kyoung Hyo; Kim, Won
2017-04-01
The present study investigated the prevalence and risk factors of adhesive capsulitis of the shoulder in breast cancer patients between 13 and 18 months after surgery. This study included 271 women who underwent surgery for breast cancer with a postoperative period of 13-18 months. Current adhesive capsulitis was defined as restriction of external rotation and one or more additional directional restrictions with history of shoulder pain. Cumulative adhesive capsulitis was defined as current adhesive capsulitis or a previous history of adhesive capsulitis after breast cancer surgery. Multivariate logistic regression analysis was performed to examine associations between current or cumulative adhesive capsulitis and potential risk factors. Among the 271 study patients, 28 (10.3%) and 21 (7.7%) had cumulative or current adhesive capsulitis, respectively. The incidences of cumulative and current adhesive capsulitis were higher in those aged 50-59 years (odds ratio [OR], 9.912; 95% confidence interval [CI], 1.790-54.880; and OR, 12.395; 95% CI, 1.187-129.444, respectively) and those who underwent mastectomy (OR, 6.805; 95% CI, 1.800-25.733; and OR, 9.645; 95% CI, 2.075-44.829, respectively) or mastectomy with reconstruction (OR, 13.122; 95% CI, 2.488-69.218; and OR, 20.075; 95% CI, 2.873-140.261, respectively). Adhesive capsulitis of the shoulder is a common problem after breast cancer treatment. An age of 50-59 years and mastectomy are major risk factors for adhesive capsulitis, and breast reconstruction additionally increases the risk. Patients with these risk factors require greater attention for early diagnosis and proper treatment.
de la Peña, Amparo; Seger, Mary; Rave, Klaus; Heinemann, Lutz; Silverman, Bernard; Muchmore, Douglas B
2009-09-01
In order to assess pharmacokinetic (PK) and glucodynamic (GD) attributes relevant to the end user of an inhaled insulin, this study examined the exposure and GD effect of doses of AIR inhaled insulin (Eli Lilly and Co., Indianapolis, IN) (AIR is a registered trademark of Alkermes, Inc., Cambridge, MA) by combining capsules of different strengths in healthy subjects. Fifty-nine healthy, nonsmoking, male or female subjects with normal pulmonary function were enrolled in an open-label, randomized, crossover study. Subjects underwent up to five euglycemic glucose clamp procedures, separated by 5-18 days. The five AIR insulin treatments tested included one 6 unit-equivalent (U-eq) capsule containing 2.6 mg of insulin, three 2 U-eq (0.9 mg) capsules (2.7 mg total), one 10 U-eq (3.9 mg) capsule, one 6 U-eq capsule plus two 2 U-eq capsules (4.4 mg total), and two 10 U-eq capsules (7.8 mg total). Samples for PK and GD assessments were taken up to 10 h post-dose. Based on both PK (area under the curve from time 0 to time of return to baseline and maximum concentration) and GD (total amount of glucose infused and maximum glucose infusion rate) responses, administration of a 6 U-eq capsule was equivalent to three 2 U-eq capsules; 90% confidence intervals for the ratios were contained within the interval (0.8, 1.25). Similarly, both overall exposure and glucodynamic response after administration of a 10 U-eq capsule were comparable to the 6 U-eq plus two 2 U-eq capsule combination. AIR insulin exhibited PK dose proportionality and dose-dependent increases in GD responses over the 2.6-7.8 mg dose range. AIR insulin exhibited dose strength interchangeability and dose proportionality after single-dose administration in healthy subjects.
Cao, Wei; Huang, Renliang; Qi, Wei; Su, Rongxin; He, Zhimin
2015-01-14
Encapsulation of enzymes during the creation of an emulsion is a simple and efficient route for enhancing enzyme catalysis in organic media. Herein, we report a capsule with a shell comprising a monolayer of silica Janus particles (JPs) (referred to as a monolayer capsule) and a Pickering emulsion for the encapsulation of enzyme molecules for catalysis purposes in organic media using amphiphilic silica JPs as building blocks. We demonstrate that the JP capsules had a monolayer shell consisting of closely packed silica JPs (270 nm). The capsules were on average 5-50 μm in diameter. The stability of the JP capsules (Pickering emulsion) was investigated with the use of homogeneous silica nanoparticles as a control. The results show that the emulsion stabilized via amphiphilic silica JPs presented no obvious changes in physical appearance after 15 days, indicating the high stability of the emulsions and JP capsules. Furthermore, the lipase from Candida sp. was chosen as a model enzyme for encapsulation within the JP capsules during their formation. The catalytic performance of lipase was evaluated according to the esterification of 1-hexanol with hexanoic acid. It was found that the specific activity of the encapsulated enzymes (28.7 U mL(-1)) was more than 5.6 times higher than that of free enzymes in a biphasic system (5.1 U mL(-1)). The enzyme activity was further increased by varying the volume ratio of water to oil and the JPs loadings. The enzyme-loaded capsule also exhibited high stability during the reaction process and good recyclability. In particular, the jellification of agarose in the JP capsules further enhanced their operating stability. We believe that the monolayer structure of the JP capsules, together with their high stability, rendered the capsules to be ideal enzyme carriers and microreactors for enzyme catalysis in organic media because they created a large interfacial area and had low mass transfer resistance through the monolayer shell.
Oh, D Alexander; Parikh, Neha; Khurana, Varun; Cognata Smith, Christina; Vetticaden, Santosh
2017-01-01
Dronabinol is a pharmaceutical tetrahydrocannabinol originally developed as an oral capsule. A dronabinol oral solution was recently approved, and the effects of food on absorption and bioavailability of the oral solution versus capsules were compared in an open-label, single-dose, 3-period crossover study. Healthy volunteers were randomized to either dronabinol oral solution 4.25 mg (fed) or dronabinol capsule 5 mg (fed or fasted). Dosing was separated by a 7-day washout period. Plasma pharmacokinetics were evaluated for dronabinol and its major metabolite, 11-hydroxy-delta-9-tetrahydrocannabinol (11-OH-Δ9-THC). Pharmacokinetic data were available for analysis in 54 volunteers. In the fed state, initial dronabinol absorption was faster with oral solution versus capsule (mean time to the first measurable concentration, 0.15 vs 2.02 hours, respectively), with 100% and 15% of volunteers, respectively, having detectable plasma dronabinol levels 30 minutes postdose. There was less interindividual variability in plasma dronabinol concentration during early absorption with oral solution versus capsule. Compared with the fasted state, mean area under the plasma concentration–time curve from time zero to the last measurable concentration (AUC0−t) increased by 2.1- and 2.4-fold for dronabinol oral solution and capsule, respectively, when taken with food. Mean time to maximum plasma concentration was similarly delayed for dronabinol oral solution with food (7.7 hours) and capsule with food (5.6 hours) versus capsule with fasting (1.7 hours). Under fed conditions, AUC0−t and area under the plasma concentration–time curve from time zero to infinity were similar for the oral solution versus capsule based on 11-OH-Δ9-THC levels. An appreciable food effect was observed for dronabinol oral solution and capsules. Dronabinol oral solution may offer therapeutic benefit to patients, given its rapid and lower interindividual absorption variability versus dronabinol capsule. PMID:28138268
Hawkey, C; Burnett, I; Gold, M S; Garsed, K; Stevenson, D; Mannath, J; Norman, A; Shepherd, V; Subramanian, V; Johnston, R D; Brown, M
2012-04-01
Diclofenac-potassium (diclofenac--K) 25 mg liquid capsule is absorbed more quickly than the tablet formulation. It offers potential for rapid pain relief, but may alter gastro-duodenal tolerability. To evaluate the gastro-duodenal tolerance of diclofenac-K 25 mg liquid capsules vs. diclofenac-K 12.5 mg tablets, acetylsalicylic acid (ASA) 500 mg tablets and ibuprofen 200 mg liquid capsules. In an endoscopist-blinded, randomised, parallel-group study, volunteers received 15 doses of diclofenac-K 25 mg liquid capsules (n = 36), diclofenac-K 2 × 12.5 mg tablets (n = 36), ibuprofen 2 × 200 mg liquid capsules (n = 24) or ASA 2 × 500 mg tablets (n = 36) over 5 days. The primary outcome was the incidence of erosive gastro-duodenal lesions at Day 6. Secondary outcomes included modified Lanza score and change in gastric mucosal prostaglandin synthesis. The lowest incidence of erosive gastro-duodenal lesions was with diclofenac-K liquid capsules (53%), compared to 61% with diclofenac-K tablets (P = 0.52), 75% with ibuprofen (P = 0.08) and 94% with ASA (P = 0.001). Results were similar for the Lanza scores, although diclofenac-K liquid capsules were significantly superior to ibuprofen liquid capsules (P = 0.04). Diclofenac-K liquid capsules inhibited prostaglandin synthesis by 52% compared to 64% for diclofenac-K tablets (P = 0.10), 50% for ibuprofen (P = 0.85) and 79% for ASA (P = 0.002). With respect to safety, adverse events were most frequent in the ASA group, predominantly gastrointestinal events. Mucosal injury with diclofenac-K liquid 25 mg liquid capsules was similar to diclofenac-K 25 mg tablets, significantly lower than ASA 1 g tablets and showed some superiority over ibuprofen 400 mg liquid capsules (EudraCT Number 2009-011278-14). © 2012 Blackwell Publishing Ltd.
Kodithuwakku, Nandani Darshika; Pan, Min; Zhu, Yi-lin; Zhang, Yan-yan; Feng, Yi-dong; Fang, Wei-rong; Li, Yun-man
2013-12-12
Shuang-Qi gout capsule is a traditional Chinese medicine prescription, which has been used in the treatment of joint pain, inflammation and gout arthritis. This study evaluates anti-inflammatory and antinociceptive effects of Shuang-Qi gout capsule and its modulation of pro-inflammatory cytokines with special reference to gout arthritis. Anti-inflammatory effect of Shuang-Qi gout capsule was investigated bymice tail-flick response, acetic acid induced writhing response, Xylene-induced auricle inflammation and the hind paw volume of the monosodium urate (MSU) crystal induced rats with different time durations. To investigate the effects on gout arthritis, ankle joint of rats induced by MSU crystals and assessed for edema and histopathological changes. In vitro, prepared serum was incubated with urate crystal induced HUVE cells and the release of TNF-α and IL-1β determined by ELISA. Shuang-Qi gout capsule showed significant and dose dependent anti-inflammatory effect via reducing edema and pain, throughout all the models. The high dose of Shuang-Qi gout capsule and Indomethacin significantly attenuated the edema. Histopathological results showed that high and medium dose of Shuang-Qi gout capsule and Indomethacin reduced gouty joint inflammatory features, while the high dose of Shuang-Qi gout capsule showed a better therapeutic effect. High and medium dose of Shuang-Qi gout capsule significantly reduced the release of TNF-α and IL-1β (p<0.05). Shuang-Qi gout capsule can effectively inhibit the inflammation, analgesia, through the modulation of emission of pro-inflammatory cytokines and the curative effect is dose dependent. Conversely, these MSU induced in vivo and in vitro studies of Shuang-Qi gout capsule suggest that, Shuang-Qi gout capsule may be a potential agent for treatment in gouty arthritis. © 2013 Published by Elsevier Ireland Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Starr, Kimberly F.; Porsch, Eric A.; Seed, Patrick C.
Kingella kingae is an encapsulated gram-negative organism that is a common cause of osteoarticular infections in young children. In earlier work, we identified a glycosyltransferase gene called csaA that is necessary for synthesis of the [3)-β-GalpNAc-(1→5)-β-Kdop-(2→] polysaccharide capsule (type a) in K. kingae strain 269–492. In the current study, we analyzed a large collection of invasive and carrier isolates from Israel and found that csaA was present in only 47% of the isolates. Further examination of this collection using primers based on the sequence that flanks csaA revealed three additional gene clusters (designated the csb, csc, and csd loci), allmore » encoding predicted glycosyltransferases. The csb locus contains the csbA, csbB, and csbC genes and is associated with a capsule that is a polymer of [6)-α-GlcpNAc-(1→5)-β-(8-OAc)Kdop-(2→] (type b). The csc locus contains the cscA, cscB, and cscC genes and is associated with a capsule that is a polymer of [3)-β-Ribf-(1→2)-β-Ribf-(1→2)-β-Ribf-(1→4)-β-Kdop-(2→] (type c). The csd locus contains the csdA, csdB, and csdC genes and is associated with a capsule that is a polymer of [P-(O→3)[β-Galp-(1→4)]-β-GlcpNAc-(1→3)-α-GlcpNAc-1-] (type d). Introduction of the csa, csb, csc, and csd loci into strain KK01Δcsa, a strain 269–492 derivative that lacks the native csaA gene, was sufficient to produce the type a capsule, type b capsule, type c capsule, and type d capsule, respectively, indicating that these loci are solely responsible for determining capsule type in K. kingae. Further analysis demonstrated that 96% of the invasive isolates express either the type a or type b capsule and that a disproportionate percentage of carrier isolates express the type c or type d capsule. Lastly, these results establish that there are at least four structurally distinct K. kingae capsule types and suggest that capsule type plays an important role in promoting K. kingae invasive disease« less
Starr, Kimberly F.; Porsch, Eric A.; Seed, Patrick C.; ...
2016-10-19
Kingella kingae is an encapsulated gram-negative organism that is a common cause of osteoarticular infections in young children. In earlier work, we identified a glycosyltransferase gene called csaA that is necessary for synthesis of the [3)-β-GalpNAc-(1→5)-β-Kdop-(2→] polysaccharide capsule (type a) in K. kingae strain 269–492. In the current study, we analyzed a large collection of invasive and carrier isolates from Israel and found that csaA was present in only 47% of the isolates. Further examination of this collection using primers based on the sequence that flanks csaA revealed three additional gene clusters (designated the csb, csc, and csd loci), allmore » encoding predicted glycosyltransferases. The csb locus contains the csbA, csbB, and csbC genes and is associated with a capsule that is a polymer of [6)-α-GlcpNAc-(1→5)-β-(8-OAc)Kdop-(2→] (type b). The csc locus contains the cscA, cscB, and cscC genes and is associated with a capsule that is a polymer of [3)-β-Ribf-(1→2)-β-Ribf-(1→2)-β-Ribf-(1→4)-β-Kdop-(2→] (type c). The csd locus contains the csdA, csdB, and csdC genes and is associated with a capsule that is a polymer of [P-(O→3)[β-Galp-(1→4)]-β-GlcpNAc-(1→3)-α-GlcpNAc-1-] (type d). Introduction of the csa, csb, csc, and csd loci into strain KK01Δcsa, a strain 269–492 derivative that lacks the native csaA gene, was sufficient to produce the type a capsule, type b capsule, type c capsule, and type d capsule, respectively, indicating that these loci are solely responsible for determining capsule type in K. kingae. Further analysis demonstrated that 96% of the invasive isolates express either the type a or type b capsule and that a disproportionate percentage of carrier isolates express the type c or type d capsule. Lastly, these results establish that there are at least four structurally distinct K. kingae capsule types and suggest that capsule type plays an important role in promoting K. kingae invasive disease« less
Analysing intracellular deformation of polymer capsules using structured illumination microscopy
NASA Astrophysics Data System (ADS)
Chen, Xi; Cui, Jiwei; Sun, Huanli; Müllner, Markus; Yan, Yan; Noi, Ka Fung; Ping, Yuan; Caruso, Frank
2016-06-01
Understanding the behaviour of therapeutic carriers is important in elucidating their mechanism of action and how they are processed inside cells. Herein we examine the intracellular deformation of layer-by-layer assembled polymer capsules using super-resolution structured illumination microscopy (SIM). Spherical- and cylindrical-shaped capsules were studied in three different cell lines, namely HeLa (human epithelial cell line), RAW264.7 (mouse macrophage cell line) and differentiated THP-1 (human monocyte-derived macrophage cell line). We observed that the deformation of capsules was dependent on cell line, but independent of capsule shape. This suggests that the mechanical forces, which induce capsule deformation during cell uptake, vary between cell lines, indicating that the capsules are exposed to higher mechanical forces in HeLa cells, followed by RAW264.7 and then differentiated THP-1 cells. Our study demonstrates the use of super-resolution SIM in analysing intracellular capsule deformation, offering important insights into the cellular processing of drug carriers in cells and providing fundamental knowledge of intracellular mechanobiology. Furthermore, this study may aid in the design of novel drug carriers that are sensitive to deformation for enhanced drug release properties.Understanding the behaviour of therapeutic carriers is important in elucidating their mechanism of action and how they are processed inside cells. Herein we examine the intracellular deformation of layer-by-layer assembled polymer capsules using super-resolution structured illumination microscopy (SIM). Spherical- and cylindrical-shaped capsules were studied in three different cell lines, namely HeLa (human epithelial cell line), RAW264.7 (mouse macrophage cell line) and differentiated THP-1 (human monocyte-derived macrophage cell line). We observed that the deformation of capsules was dependent on cell line, but independent of capsule shape. This suggests that the mechanical forces, which induce capsule deformation during cell uptake, vary between cell lines, indicating that the capsules are exposed to higher mechanical forces in HeLa cells, followed by RAW264.7 and then differentiated THP-1 cells. Our study demonstrates the use of super-resolution SIM in analysing intracellular capsule deformation, offering important insights into the cellular processing of drug carriers in cells and providing fundamental knowledge of intracellular mechanobiology. Furthermore, this study may aid in the design of novel drug carriers that are sensitive to deformation for enhanced drug release properties. Electronic supplementary information (ESI) available: Additional figures. See DOI: 10.1039/c6nr02151d
Xu, Chang; Li, Erchao; Suo, Yantong; Su, Yujie; Lu, Minghui; Zhao, Qun; Qin, Jian G; Chen, Liqiao
2018-05-01
Hyperosmotic stress can adversely affect fish immunity, but little is known about the histological and transcriptomic responses of immune organs in fish in a hyperosmotic environment. This study evaluated the effects of long-term hypersaline conditions (16‰) on the growth, histology and transcriptomics of the two main immune organs, the spleen and head kidney, in Nile tilapia Oreochromis niloticus relative to those reared in freshwater for eight weeks. No differences in weight gain and specific growth rate were found between fish reared under these two salinities. Hyperosmotic stress induced a congestive or enlarged spleen. Platelet- and coagulation-related gene expression was significantly decreased in tilapia at 16‰. The red cell distribution width and value of the mean corpuscular hemoglobin were significantly greater in fish at 16‰ salinity than in control fish in freshwater. A large volume of melano-macrophages in the spleen and pigment deposition in both the spleen and head kidney were observed in the histological sections in fish at 16‰ salinity. Transmission electron microscopic results showed abnormal macrophages with deposition granules in the spleen and head kidney and more neutrophils in the head kidney of fish at 16‰ than in control fish. In total, 772 and 502 genes were annotated for significantly different expression in the spleen and head kidney, respectively, and corresponded to five and one significantly changed immune system pathways, respectively. The complement pathway in the spleen was significantly down-regulated at 16‰. This study indicates that long-term exposure of Nile tilapia to a hyperosmotic environment can induce splenomegaly, reduce coagulation function, enhance phagocytic activity and down-regulate the complement pathway in the spleen. The spleen is a more sensitive organ for immune responses to chronic ambient salinity stress than the head kidney in Nile tilapia. Copyright © 2018 Elsevier Ltd. All rights reserved.
Hogge, Carla I; Campbell, Matthew R; Johnson, Keith A
2008-02-01
A new species of Myxosporea, Myxobolus neurotropus n. sp., is described from the brain and spinal cord of rainbow trout (Oncorhynchus mykiss) from Duncan Creek, Owyhee County, Idaho. Spores are oval, have 2 pyriform polar capsules, and possess a thick spore wall (sutural rim) with a short intracapsular offshoot. The mean spore dimensions are length 11.8 microm, width 10.8 microm, and thickness 8.8 microm. This myxozoan is compared to other described Myxobolus species found in cranial tissues of salmonids in terms of spore morphology and phylogenetic analysis. Because it is found in brain and spinal cord, it is encountered while performing screening tests for Myxobolus cerebralis, the causative agent of salmonid whirling disease. Where chronic inflammation and granulomatous lesions are associated with M. cerebralis, histological examination shows no host response to M. neurotropus n. sp. A diagnostic polymerase chain reaction (PCR) test is included as an aid in properly identifying the species.
Optical and tomographic imaging of a middle ear malformation in the bullfrog (Rana catesbeiana).
Horowitz, Seth S; Simmons, Andrea Megela; Ketten, Darlene R
2005-08-01
Using a combination of in vivo computerized tomography and histological staining, a middle ear anomaly in two wild-caught American bullfrogs (Rana catesbeiana) is characterized. In these animals, the tympanic membrane, extrastapes, and pars media (shaft) of the stapes are absent on one side of the head, with the other side exhibiting normal morphology. The pars interna (footplate) of the stapes and the operculum are present in their normal positions at the entrance of the otic capsule on both the affected and unaffected sides. The pattern of deformity suggests a partial failure of development of tympanic pathway tissues, but with a preservation of the opercularis pathway. While a definitive proximate cause of the condition could not be determined, the anomalies show similarities to developmental defects in mammalian middle ear formation.
Optical and tomographic imaging of a middle ear malformation in the bullfrog (Rana catesbeiana)
Horowitz, Seth S.; Simmons, Andrea Megela; Ketten, Darlene R.
2005-01-01
Using a combination of in vivo computerized tomography and histological staining, a middle ear anomaly in two wild-caught American bullfrogs (Rana catesbeiana) is characterized. In these animals, the tympanic membrane, extrastapes, and pars media (shaft) of the stapes are absent on one side of the head, with the other side exhibiting normal morphology. The pars interna(footplate) of the stapes and the operculum are present in their normal positions at the entrance of the otic capsule on both the affected and unaffected sides. The pattern of deformity suggests a partial failure of development of tympanic pathway tissues, but with a preservation of theopercularis pathway. While a definitive proximate cause of the condition could not be determined, the anomalies show similarities to developmental defects in mammalian middle ear formation. PMID:16158670